  1. Molecular Imaging in Breast Cancer: From Whole-Body PET/CT to Dedicated Breast PET

    Directory of Open Access Journals (Sweden)

    B. B. Koolen

    2012-01-01

    Full Text Available Positron emission tomography (PET, with or without integrated computed tomography (CT, using 18F-fluorodeoxyglucose (FDG is based on the principle of elevated glucose metabolism in malignant tumors, and its use in breast cancer patients is frequently being investigated. It has been shown useful for classification, staging, and response monitoring, both in primary and recurrent disease. However, because of the partial volume effect and limited resolution of most whole-body PET scanners, sensitivity for the visualization of small tumors is generally low. To improve the detection and quantification of primary breast tumors with FDG PET, several dedicated breast PET devices have been developed. In this nonsystematic review, we shortly summarize the value of whole-body PET/CT in breast cancer and provide an overview of currently available dedicated breast PETs.

  2. A dedicated breast-PET/CT scanner: Evaluation of basic performance characteristics.

    Science.gov (United States)

    Raylman, Raymond R; Van Kampen, Will; Stolin, Alexander V; Gong, Wenbo; Jaliparthi, Gangadhar; Martone, Peter F; Smith, Mark F; Sarment, David; Clinthorne, Neal H; Perna, Mark

    2018-04-01

    Application of advanced imaging techniques, such as PET and x ray CT, can potentially improve detection of breast cancer. Unfortunately, both modalities have challenges in the detection of some lesions. The combination of the two techniques, however, could potentially lead to an overall improvement in diagnostic breast imaging. The purpose of this investigation is to test the basic performance of a new dedicated breast-PET/CT. The PET component consists of a rotating pair of detectors. Its performance was evaluated using the NEMA NU4-2008 protocols. The CT component utilizes a pulsed x ray source and flat panel detector mounted on the same gantry as the PET scanner. Its performance was assessed using specialized phantoms. The radiation dose to a breast during CT imaging was explored by the measurement of free-in-air kerma and air kerma measured at the center of a 16 cm-diameter PMMA cylinder. Finally, the combined capabilities of the system were demonstrated by imaging of a micro-hot-rod phantom. Overall, performance of the PET component is comparable to many pre-clinical and other dedicated breast-PET scanners. Its spatial resolution is 2.2 mm, 5 mm from the center of the scanner using images created with the single-sliced-filtered-backprojection algorithm. Peak NECR is 24.6 kcps; peak sensitivity is 1.36%; the scatter fraction is 27%. Spatial resolution of the CT scanner is 1.1 lp/mm at 10% MTF. The free-in-air kerma is 2.33 mGy, while the PMMA-air kerma is 1.24 mGy. Finally, combined imaging of a micro-hot-rod phantom illustrated the potential utility of the dual-modality images produced by the system. The basic performance characteristics of a new dedicated breast-PET/CT scanner are good, demonstrating that its performance is similar to current dedicated PET and CT scanners. The potential value of this system is the capability to produce combined duality-modality images that could improve detection of breast disease. The next stage in development of this system

  3. Design and evaluation of the MAMMI dedicated breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; González, A. J.; Soriano, A.; Sánchez, F.; Correcher, C.; Orero, A.; Carles, M.; Vidal, L. F.; Barberá, J.; Caballero, L.; Seimetz, M.; Vázquez, C.; Benlloch, J. M.

    2012-01-01

    Purpose: A breast dedicated positron emission tomography (PET) scanner has been developed based on monolithic LYSO crystals coupled to position sensitive photomultiplier tubes (PSPMTs). In this study, we describe the design of the PET system and report on its performance evaluation. Methods: MAMMI is a breast PET scanner based on monolithic LYSO crystals. It consists of 12 compact modules with a transaxial field of view (FOV) of 170 mm in diameter and 40 mm axial FOV that translates to cover up to 170 mm. The patient lies down in a prone position that facilitates maximum breast elongation. Quantitative performance analysis of the calculated method for the attenuation correction specifically developed for MAMMI, and based on PET image segmentation, has also been conducted in this evaluation. In order to fully determine the MAMMI prototype's performance, we have adapted the measurements suggested for National Electrical Manufacturers Association (NEMA) NU 2-2007 and NU 4-2008 protocol tests, as they are defined for whole-body and small animal PET scanners, respectively. Results: Spatial resolutions of 1.6, 1.8, and 1.9 mm were measured in the axial, radial, and tangential directions, respectively. A scatter fraction of 20.8% was obtained and the maximum NEC was determined to be 25 kcps at 44 MBq. The average sensitivity of the system was observed to be 1% for an energy window of (250 keV–750 keV) and a maximum absolute sensitivity of 1.8% was measured at the FOV center. Conclusions: The overall performance of the MAMMI reported on this evaluation quantifies its ability to produce high quality PET images. Spatial resolution values below 3 mm were measured in most of the FOV. Only the radial component of spatial resolution exceeds the 3 mm at radial positions larger than 60 mm. This study emphasizes the need for standardized testing methodologies for dedicated breast PET systems similar to NEMA standards for whole-body and small animal PET scanners.

  4. Performance evaluation of a high resolution dedicated breast PET scanner

    Energy Technology Data Exchange (ETDEWEB)

    García Hernández, Trinitat, E-mail: mtrinitat@eresa.com; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del [Department of Nuclear Medicine, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Roselló Ferrando, Joan [Department of Medical Physics, ERESA, Hospital General Universitario, Valencia 46014 (Spain); Department of Physiology, University of Valencia, Valencia 46010 (Spain)

    2016-05-15

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ({sup 18}F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good

  5. Performance evaluation of a high resolution dedicated breast PET scanner

    International Nuclear Information System (INIS)

    García Hernández, Trinitat; Vicedo González, Aurora; Brualla González, Luis; Granero Cabañero, Domingo; Ferrer Rebolleda, Jose; Sánchez Jurado, Raúl; Puig Cozar Santiago, Maria del; Roselló Ferrando, Joan

    2016-01-01

    Purpose: Early stage breast cancers may not be visible on a whole-body PET scan. To overcome whole-body PET limitations, several dedicated breast positron emission tomography (DbPET) systems have emerged nowadays aiming to improve spatial resolution. In this work the authors evaluate the performance of a high resolution dedicated breast PET scanner (Mammi-PET, Oncovision). Methods: Global status, uniformity, sensitivity, energy, and spatial resolution were measured. Spheres of different sizes (2.5, 4, 5, and 6 mm diameter) and various 18 fluorodeoxyglucose ("1"8F-FDG) activity concentrations were randomly inserted in a gelatine breast phantom developed at our institution. Several lesion-to-background ratios (LBR) were simulated, 5:1, 10:1, 20:1, 30:1, and 50:1. Images were reconstructed using different voxel sizes. The ability of experienced reporters to detect spheres was tested as a function of acquisition time, LBR, sphere size, and matrix reconstruction voxel size. For comparison, phantoms were scanned in the DbPET camera and in a whole body PET (WB-PET). Two patients who just underwent WB-PET/CT exams were imaged with the DbPET system and the images were compared. Results: The measured absolute peak sensitivity was 2.0%. The energy resolution was 24.0% ± 1%. The integral and differential uniformity were 10% and 6% in the total field of view (FOV) and 9% and 5% in the central FOV, respectively. The measured spatial resolution was 2.0, 1.9, and 1.7 mm in the radial, tangential, and axial directions. The system exhibited very good detectability for spheres ≥4 mm and LBR ≥10 with a sphere detection of 100% when acquisition time was set >3 min/bed. For LBR = 5 and acquisition time of 7 min the detectability was 100% for spheres of 6 mm and 75% for spheres of 5, 4, and 2.5 mm. Lesion WB-PET detectability was only comparable to the DbPET camera for lesion sizes ≥5 mm when acquisition time was >3 min and LBR > 10. Conclusions: The DbPET has a good performance

  6. Development of a circular shape Si-PM-based detector ring for breast-dedicated PET system

    Science.gov (United States)

    Nakanishi, Kouhei; Yamamoto, Seiichi; Watabe, Hiroshi; Abe, Shinji; Fujita, Naotoshi; Kato, Katsuhiko

    2018-02-01

    In clinical situations, various breast-dedicated positron emission tomography (PET) systems have been used. However, clinical breast-dedicated PET systems have polygonal detector ring. Polygonal detector ring sometimes causes image artifact, so complicated reconstruction algorithm is needed to reduce artifact. Consequently, we developed a circular detector ring for breast-dedicated PET to obtain images without artifact using a simple reconstruction algorithm. We used Lu1.9Gd0.1SiO5 (LGSO) scintillator block which was made of 1.5 x 1.9 x 15 mm pixels that were arranged in an 8 x 24 matrix. As photodetectors, we used silicon photomultiplier (Si-PM) arrays whose channel size was 3 x 3 mm. A detector unit was composed of four scintillator blocks, 16 Si-PM arrays and a light guide. The developed detector unit had angled configuration since the light guide was bending. A detector unit had three gaps with an angle of 5.625° between scintillator blocks. With these configurations, we could arrange 64 scintillator blocks in nearly circular shape (regular 64-sided polygon) using 16 detector units. The use of the smaller number of detector units could reduce the size of the front-end electronics circuits. The inner diameter of the developed detector ring was 260 mm. This size was similar to those of brain PET systems, so our breast-dedicated PET detector ring can measure not only breast but also brain. Measured radial, tangential and axial spatial resolution of the detector ring reconstructed by the filtered back-projection (FBP) algorithm were 2.1 mm FWHM, 2.0 mm FWHM and 1.7 mm FWHM at center of field of view (FOV), respectively. The sensitivity was 2.0% at center of the axial FOV. With the developed detector ring, we could obtain high resolution image of the breast phantom and the brain phantom. We conclude that our developed Si-PM-based detector ring is promising for a high resolution breast-dedicated PET system that can also be used for brain PET system.

  7. Texture analysis of high-resolution dedicated breast {sup 18}F-FDG PET images correlates with immunohistochemical factors and subtype of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Moscoso, Alexis; Dominguez-Prado, Ines; Herranz, Michel; Argibay, Sonia; Silva-Rodriguez, Jesus [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Ruibal, Alvaro [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain); Fundacion Tejerina, Madrid (Spain); Fernandez-Ferreiro, Anxo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Pharmacy Department and Pharmacology Group, Santiago de Compostela (Spain); Albaina, Luis [University Hospital A Coruna (SERGAS), Department of General Surgery, A Coruna (Spain); Pardo-Montero, Juan [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); Complexo Hospitalario Universitario de Santiago de Compostela (CHUS), Medical Physics Department, Santiago de Compostela (Spain); Aguiar, Pablo [Complexo Hospitalario Universitario de Santiago de Compostela CHUS-IDIS, Nuclear Medicine Department and Molecular Imaging Group, Santiago de Compostela (Spain); University of Santiago de Compostela (USC), Molecular Imaging Group, Department of Radiology, Faculty of Medicine, Santiago de Compostela (Spain)

    2018-02-15

    This study aims to determine whether PET textural features measured with a new dedicated breast PET scanner reflect biological characteristics of breast tumors. One hundred and thirty-nine breast tumors from 127 consecutive patients were included in this analysis. All of them underwent a {sup 18}F-FDG PET scan before treatment. Well-known PET quantitative parameters such as SUV{sub m} {sub a} {sub x}, SUV{sub m} {sub e} {sub a} {sub n}, metabolically active tumor volume (MATV) and total lesion glycolysis (TLG) were extracted. Together with these parameters, local, regional, and global heterogeneity descriptors, which included five textural features (TF), were computed. Immunohistochemical classification of breast cancer considered five subtypes: luminal A like (LA), luminal B like/HER2 - (LB -), luminal B like/HER2+ (LB+), HER2-positive-non-luminal (HER2pnl), and triple negative (TN). Associations between PET features and tumor characteristics were assessed using non-parametric hypothesis tests. Along with well-established associations, new correlations were found. HER2-positive tumors had significantly higher uptake (p < 0.001, AUCs > 0.70) and presented different global and regional heterogeneity (p = 0.002, p = 0.016, respectively, AUCs < 0.70). Nine out of ten analyzed features were significantly associated with immunohistochemical subtype. Uptake was lower for LA tumors (p < 0.001) with AUCs ranging from 0.71 to 0.88 for each subgroup comparison. Heterogeneity metrics were significantly associated when comparing LA and LB - (p < 0.01), being regional heterogeneity metrics more discriminative than any other parameter (AUC = 0.80 compared to AUC = 0.71 for SUV). LB+ and HER2pnl tumors also showed more regional heterogeneity than LA tumors (AUCs = 0.79 and 0.84, respectively). After comparison with whole-body PET studies, we observed an overall improvement in the classification ability of both non-heterogeneity metrics and textural features. PET parameters

  8. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, Thiemo J.A. van; Goorts, B. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Voeoe, S.; Wildberger, J.E. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Boer, M. de [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Division of Internal Medicine, Department of Medical Oncology, Maastricht (Netherlands); Kooreman, L.F.S. [Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center+, Department of Pathology, Maastricht (Netherlands); Heuts, E.M. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Mottaghy, F.M. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); RWTH Aachen University, Department of Nuclear Medicine, University Hospital, Aachen (Germany); Lobbes, M.B.I. [Maastricht University Medical Center+, Department of Radiology and Nuclear Medicine (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Smidt, M.L. [Maastricht University Medical Center+, Department of Surgery, Maastricht (Netherlands); Maastricht University Medical Center+, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands)

    2018-02-15

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  9. Added value of dedicated axillary hybrid 18F-FDG PET/MRI for improved axillary nodal staging in clinically node-positive breast cancer patients. A feasibility study

    International Nuclear Information System (INIS)

    Nijnatten, Thiemo J.A. van; Goorts, B.; Voeoe, S.; Wildberger, J.E.; Boer, M. de; Kooreman, L.F.S.; Heuts, E.M.; Mottaghy, F.M.; Lobbes, M.B.I.; Smidt, M.L.

    2018-01-01

    To investigate the feasibility and potential added value of dedicated axillary 18F-FDG hybrid PET/MRI, compared to standard imaging modalities (i.e. ultrasound [US], MRI and PET/CT), for axillary nodal staging in clinically node-positive breast cancer. Twelve patients with clinically node-positive breast cancer underwent axillary US and dedicated axillary hybrid 18F-FDG PET/MRI. Nine of the 12 patients also underwent whole-body PET/CT. Maximum standardized uptake values (SUVmax) were measured for the primary breast tumor and the most FDG-avid axillary lymph node. A positive axillary lymph node on dedicated axillary hybrid PET/MRI was defined as a moderate to very intense FDG-avid lymph node. The diagnostic performance of dedicated axillary hybrid PET/MRI was calculated by comparing quantitative and its qualitative measurements to results of axillary US, MRI and PET/CT. The number of suspicious axillary lymph nodes was subdivided as follows: N0 (0 nodes), N1 (1-3 nodes), N2 (4-9 nodes) and N3 (≥ 10 nodes). According to dedicated axillary hybrid PET/MRI findings, seven patients were diagnosed with N1, four with N2 and one with N3. With regard to mean SUVmax, there was no significant difference in the primary tumor (9.0 [±5.0] vs. 8.6 [±5.7], p = 0.678) or the most FDG-avid axillary lymph node (7.8 [±5.3] vs. 7.7 [±4.3], p = 0.767) between dedicated axillary PET/MRI and PET/CT. Compared to standard imaging modalities, dedicated axillary hybrid PET/MRI resulted in changes in nodal status as follows: 40% compared to US, 75% compared to T2-weighted MRI, 40% compared to contrast-enhanced MRI, and 22% compared to PET/CT. Adding dedicated axillary 18F-FDG hybrid PET/MRI to diagnostic work-up may improve the diagnostic performance of axillary nodal staging in clinically node-positive breast cancer patients. (orig.)

  10. Combined SPECT/CT and PET/CT for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Russo, Paolo [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Larobina, Michele [Istituto di Biostrutture e Bioimmagini, Consiglio Nazionale delle Ricerche, Via Tommaso De Amicis, 95, Naples I-80145 (Italy); Di Lillo, Francesca [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy); Del Vecchio, Silvana [Università di Napoli Federico II, Dipartimento di Scienze Biomediche Avanzate, Via Pansini, 5, Naples I-80131 (Italy); Mettivier, Giovanni, E-mail: mettivier@na.infn.it [Università di Napoli Federico II, Dipartimento di Fisica, Via Cintia, Naples I-80126 (Italy); INFN Sezione di Napoli, Via Cintia, Naples I-80126 (Italy)

    2016-02-11

    In the field of nuclear medicine imaging, breast imaging for cancer diagnosis is still mainly based on 2D imaging techniques. Three-dimensional tomographic imaging with whole-body PET or SPECT scanners, when used for imaging the breast, has performance limits in terms of spatial resolution and sensitivity, which can be overcome only with a dedicated instrumentation. However, only few hybrid imaging systems for PET/CT or SPECT/CT dedicated to the breast have been developed in the last decade, providing complementary functional and anatomical information on normal breast tissue and lesions. These systems are still under development and clinical trials on just few patients have been reported; no commercial dedicated breast PET/CT or SPECT/CT is available. This paper reviews combined dedicated breast PET/CT and SPECT/CT scanners described in the recent literature, with focus on their technological aspects.

  11. Time of flight measurements based on FPGA using a breast dedicated PET

    International Nuclear Information System (INIS)

    Aguilar, A; García-Olcina, R; Martos, J; Soret, J; Torres, J; Benlloch, J M; González, A J; Sánchez, F

    2014-01-01

    In this work the implementation of a Time-to-Digital Converter (TDC) using a Nutt delay line FPGA-based and applied on a Positron Emission Tomography (PET) device is going to be presented in order to check the system's suitability for Time of Flight (TOF) measurements. In recent years, FPGAs have shown great advantages for precise time measurements in PET. The architecture employed for these measurements is described in detail. The system developed was tested on a dedicated breast PET prototype, composed of LYSO crystals and Positive Sensitive Photomultipliers (PSPMTs). Two distinct experiments were carried out for this purpose. In the first test, system linearity was evaluated in order to calibrate the time measurements, providing a linearity error of less than 2% and an average time resolution of 1.4 ns FWHM. The second set of measurements tested system resolution, resulting in a FWHM as good as 1.35 ns. The results suggest that the coincidence window for the current PET can be reduced in order to minimize the random events and thus, achieve better image quality

  12. Design study of a high-resolution breast-dedicated PET system built from cadmium zinc telluride detectors

    International Nuclear Information System (INIS)

    Peng Hao; Levin, Craig S

    2010-01-01

    We studied the performance of a dual-panel positron emission tomography (PET) camera dedicated to breast cancer imaging using Monte Carlo simulation. The proposed system consists of two 4 cm thick 12 x 15 cm 2 area cadmium zinc telluride (CZT) panels with adjustable separation, which can be put in close proximity to the breast and/or axillary nodes. Unique characteristics distinguishing the proposed system from previous efforts in breast-dedicated PET instrumentation are the deployment of CZT detectors with superior spatial and energy resolution, using a cross-strip electrode readout scheme to enable 3D positioning of individual photon interaction coordinates in the CZT, which includes directly measured photon depth-of-interaction (DOI), and arranging the detector slabs edge-on with respect to incoming 511 keV photons for high photon sensitivity. The simulation results show that the proposed CZT dual-panel PET system is able to achieve superior performance in terms of photon sensitivity, noise equivalent count rate, spatial resolution and lesion visualization. The proposed system is expected to achieve ∼32% photon sensitivity for a point source at the center and a 4 cm panel separation. For a simplified breast phantom adjacent to heart and torso compartments, the peak noise equivalent count (NEC) rate is predicted to be ∼94.2 kcts s -1 (breast volume: 720 cm 3 and activity concentration: 3.7 kBq cm -3 ) for a ∼10% energy window around 511 keV and ∼8 ns coincidence time window. The system achieves 1 mm intrinsic spatial resolution anywhere between the two panels with a 4 cm panel separation if the detectors have DOI resolution less than 2 mm. For a 3 mm DOI resolution, the system exhibits excellent sphere resolution uniformity (σ rms /mean) ≤ 10%) across a 4 cm width FOV. Simulation results indicate that the system exhibits superior hot sphere visualization and is expected to visualize 2 mm diameter spheres with a 5:1 activity concentration ratio within

  13. Progress on dedicated animal PET

    International Nuclear Information System (INIS)

    Liu Wei

    2002-01-01

    Positron emission tomography, as the leading technology providing molecular imaging of biological processes, is widely used on living laboratory animals. High-resolution dedicated animal PET scanners have been developed. Although the dedicated animal PET faces obstacles and challenges, this advanced technology would play an important role in molecular biomedicine researches, such as diseases study, medicine development, and gene therapy

  14. ClearPEM: prototype PET device dedicated to breast imaging

    CERN Multimedia

    Joao Varela

    2009-01-01

    Clinical trials have begun in Portugal on a new breast imaging system (ClearPEM) using positron emission tomography (PET). The system, developed by a Portuguese consortium in collaboration with CERN and laboratories participating in the Crystal Clear collaboration, will detect even the smallest tumours and thus help avoid unnecessary biopsies.

  15. [F-18]FDG imaging of head and neck tumors: comparison of hybrid PET, dedicated PET and CT

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Poepperl, G.; Hahn, K.; Szeimies, U.

    2001-01-01

    Aim: Aim of the study was to evaluate [F-18]FDG imaging of head and neck tumors using a Hybrid-PET device of the 2nd or 3rd generation. Examinations were compared to dedicated PET and Spiral-CT. Methods: 54 patients suffering from head and neck tumors were examined using dedicated PET and Hybrid-PET after injection of 185-350 MBq [F-18]FDG. Examinations were carried out on the dedicated PET first followed by a scan on the Hybrid-PET. Dedicated PET was acquired in 3D mode, Hybrid-PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and Hybrid-PET. All patients received a CT scan in multislice technique. All finding have been verified by the goldstandard histology or in case of negative histology by follow up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using Hybrid-PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with Hybrid-PET and in 15/18 with CT. False positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and Hybrid-PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastastic lesions were seen with dedicated PET and with Hybrid-PET elsewhere in the body. Additional malignant disease other than the head and neck tumor was found in 4 patients. Conclusion: Using Hybrid-PET for [F-18]FDG imaging reveals a loss of sensitivity and specificity of about 1-5% as compared to dedicated PET in head and neck tumors. [F-18]FDG PET with both, dedicated PET and Hybrid-PET is superior to CT in the diagnosis of primary or recurrent lesions as well as in the assessment of lymph node involvement. (orig.) [de

  16. A 16-channel MR coil for simultaneous PET/MR imaging in breast cancer

    International Nuclear Information System (INIS)

    Dregely, Isabel; Lanz, Titus; Mueller, Matthias F.; Metz, Stephan; Kuschan, Marika; Nimbalkar, Manoj; Ziegler, Sibylle I.; Nekolla, Stephan G.; Schwaiger, Markus; Bundschuh, Ralph A.; Haase, Axel

    2015-01-01

    To implement and evaluate a dedicated receiver array coil for simultaneous positron emission tomography/magnetic resonance (PET/MR) imaging in breast cancer. A 16-channel receiver coil design was optimized for simultaneous PET/MR imaging. To assess MR performance, the signal-to-noise ratio, parallel imaging capability and image quality was evaluated in phantoms, volunteers and patients and compared to clinical standard protocols. For PET evaluation, quantitative 18 F-FDG PET images of phantoms and seven patients (14 lesions) were compared to images without the coil. In PET image reconstruction, a CT-based template of the coil was combined with the MR-acquired attenuation correction (AC) map of the phantom/patient. MR image quality was comparable to clinical MR-only examinations. PET evaluation in phantoms showed regionally varying underestimation of the standardised uptake value (SUV; mean 22 %) due to attenuation caused by the coil. This was improved by implementing the CT-based coil template in the AC (<2 % SUV underestimation). Patient data indicated that including the coil in the AC increased the SUV values in the lesions (21 ± 9 %). Using a dedicated PET/MR breast coil, state-of-the-art MRI was possible. In PET, accurate quantification and image homogeneity could be achieved if a CT-template of this coil was included in the AC for PET image reconstruction. (orig.)

  17. Application of PET in breast cancer

    International Nuclear Information System (INIS)

    Noh, Dong Young

    2002-01-01

    Positron emission tomography (PET) is an imaging method that employs radionuclide and tomography techniques. Since 1995, we applied PET not only to the diagnosis of breast cancer but also to the detection of abnormalities in the augmented breast and to the detection of metastasis. Until 2001, we evaluated 242 breast cases by PET at PET center of Seoul National University Hospital. Our group has reported serially at the international journals. In the firtst report, PET showed high sensitivity for detecting breast cancer, both the primary and axillary node metastasis. A total of 27 patients underwent breast operations based on PET results at Seoul National University Hospital from 1995 to 1996. The diagnostic accuracy of PET were 97% for the primary tumor mass and 96% for axillary lymph node metastasis. In case of the breast augmented, PET also showed excellent diagnostic results for primary breast cancer and axillary lymph node metastasis where mammography and ultrasound could not diagnose properly. PET also had outstanding results in the detection of recurrent or metastatic breast cancer(sensitivity 94%, specificity 80%, accuracy 89%). In addition, our study gave some evidence that PET could be applied further to evaluate the growth rate of tumors by measuring SUV, and finally to prognosticated the disease. PET could also be applied to evaluate the response after chemotherapy to measure its metabolic rate and size. In conclsion, PET is a highly sensitive, accurate diagnostic tool for breast cancer of primary lesion in various conditions including metastasis

  18. Integrated PET/MR breast cancer imaging: Attenuation correction and implementation of a 16-channel RF coil

    Energy Technology Data Exchange (ETDEWEB)

    Oehmigen, Mark, E-mail: mark.oehmigen@uni-due.de; Lindemann, Maike E. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147 (Germany); Lanz, Titus [Rapid Biomedical GmbH, Rimpar 97222 (Germany); Kinner, Sonja [Institute for Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, Essen 45147 (Germany); Quick, Harald H. [High Field and Hybrid MR Imaging, University Hospital Essen, Essen 45147, Germany and Erwin L. Hahn Institute for MR Imaging, University Duisburg-Essen, Essen 45141 (Germany)

    2016-08-15

    Purpose: This study aims to develop, implement, and evaluate a 16-channel radiofrequency (RF) coil for integrated positron emission tomography/magnetic resonance (PET/MR) imaging of breast cancer. The RF coil is designed for optimized MR imaging performance and PET transparency and attenuation correction (AC) is applied for accurate PET quantification. Methods: A 16-channel breast array RF coil was designed for integrated PET/MR hybrid imaging of breast cancer lesions. The RF coil features a lightweight rigid design and is positioned with a spacer at a defined position on the patient table of an integrated PET/MR system. Attenuation correction is performed by generating and applying a dedicated 3D CT-based template attenuation map. Reposition accuracy of the RF coil on the system patient table while using the positioning frame was tested in repeated measurements using MR-visible markers. The MR, PET, and PET/MR imaging performances were systematically evaluated using modular breast phantoms. Attenuation correction of the RF coil was evaluated with difference measurements of the active breast phantoms filled with radiotracer in the PET detector with and without the RF coil in place, serving as a standard of reference measurement. The overall PET/MR imaging performance and PET quantification accuracy of the new 16-channel RF coil and its AC were then evaluated in first clinical examinations on ten patients with local breast cancer. Results: The RF breast array coil provides excellent signal-to-noise ratio and signal homogeneity across the volume of the breast phantoms in MR imaging and visualizes small structures in the phantoms down to 0.4 mm in plane. Difference measurements with PET revealed a global loss and thus attenuation of counts by 13% (mean value across the whole phantom volume) when the RF coil is placed in the PET detector. Local attenuation ranging from 0% in the middle of the phantoms up to 24% was detected in the peripheral regions of the phantoms at

  19. Clear-PEM: A dedicated PET camera for improved breast cancer detection

    International Nuclear Information System (INIS)

    Abreu, M. C.; Almeida, P.; Balau, F.; Ferreira, N. C.; Fetal, S.; Fraga, F.; Martins, M.; Matela, N.; Moura, R.; Ortigao, C.; Peralta, L.; Rato, P.; Ribeiro, R.; Rodrigues, P.; Santos, A. I.; Trindade, A.; Varela, J.

    2005-01-01

    Positron emission mammography (PEM) can offer a non-invasive method for the diagnosis of breast cancer. Metabolic images from PEM using 18 F-fluoro-deoxy-glucose, contain unique information not available from conventional morphologic imaging techniques like X-ray radiography. In this work, the concept of Clear-PEM, the system presently developed in the frame of the Crystal Clear Collaboration at CERN, is described. Clear-PEM will be a dedicated scanner, offering better perspectives in terms of position resolution and detection sensitivity. (authors)

  20. Dedicated brain PET system of PET/MR for brain research

    International Nuclear Information System (INIS)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng

    2015-01-01

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  1. Dedicated brain PET system of PET/MR for brain research

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Li; Liu, Yaqiang; Ma, Tianyu; Wang, Shi; Wei, Qingyang; Xu, Tianpeng [Institute of Medical Physics, Department of Engineering Physics, Tsinghua University, Beijing (China)

    2015-05-18

    This work is to replace PET ring in human brain PET/MR system with a dedicated wearable PET insert, aimed at improving both patient feasibility and system performance for brain imaging. The designed PET/MR system includes two parts: the inside parts, including a radio frequency (RF) coil and PET ring, are mounted on patient’s head, and the outside part, a MR imager, is dependent of patient. The RF coil is the innermost layer, surrounded by an outer PET-ring layer. They are supported by a MRcompatible structure. And both RF coil and PET detectors are placed inside a standard clinical 3-T MR imager. From the design of the system we can infer that some advantages can be achieved. First, high sensitivity will be achieved with the same amount crystals as the PET ring is more close to region-of-interest area, at a reduced cost. Second, by using a 2-layer depth of interaction (DOI) detector, the parallax effect can be minimized. The resolution will benefit from short positron range caused by magnetic field and smaller ring diameter will also reduce the effect of non-collinearity. Thirdly, as the PET ring is mounted on head, impact of patient motion will be reduced.

  2. Detector design issues for compact nuclear emission cameras dedicated to breast imaging

    International Nuclear Information System (INIS)

    Levin, Craig S.

    2003-01-01

    Certain gamma ray and positron emitting radiotracers have shown great promise for use in the detection, diagnosis and staging of breast cancer. Unfortunately, standard nuclear emission cameras (SPECT, PET) found in the clinic are not practical for breast imaging of these emissions due to inadequate spatial and energy resolutions and sensitivity, large and awkward size, and relatively high cost per study. High spatial and energy resolutions and sensitivity are needed for good lesion detectability. Due to these limitations of standard cameras, there has been recent research into the development of small, compact nuclear emission imagers dedicated for close-proximity breast imaging. The small detector head size means a variety of exotic detectors or collimators may be implemented to improve spatial and energy resolution and sensitivity performances at a reasonable cost. In this paper, we will present some of the compact gamma ray and annihilation photon imaging detector designs that have been proposed and/or developed for dedicated breast imaging. We will review the physics and discuss the advantages and disadvantages of various detector configurations. Finally we will estimate the fundamental spatial resolution potential available with close-proximity nuclear emission imaging and discuss how one may approach those limits through proper detector design

  3. Design Optimization of a TOF, Breast PET Scanner

    OpenAIRE

    Lee, Eunsin; Werner, Matthew E.; Karp, Joel S.; Surti, Suleman

    2013-01-01

    A dedicated breast positron emission tomography (PET) scanner with limited angle geometry can provide flexibility in detector placement around the patient as well as the ability to combine it with other imaging modalities. A primary challenge of a stationary limited angle scanner is the reduced image quality due to artifacts present in the reconstructed image leading to a loss in quantitative information. Previously it has been shown that using time-of-flight (TOF) information in image recons...

  4. Iterative reconstruction using a Monte Carlo based system transfer matrix for dedicated breast positron emission tomography

    Energy Technology Data Exchange (ETDEWEB)

    Saha, Krishnendu [Ohio Medical Physics Consulting, Dublin, Ohio 43017 (United States); Straus, Kenneth J.; Glick, Stephen J. [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States); Chen, Yu. [Department of Radiation Oncology, Columbia University, New York, New York 10032 (United States)

    2014-08-28

    To maximize sensitivity, it is desirable that ring Positron Emission Tomography (PET) systems dedicated for imaging the breast have a small bore. Unfortunately, due to parallax error this causes substantial degradation in spatial resolution for objects near the periphery of the breast. In this work, a framework for computing and incorporating an accurate system matrix into iterative reconstruction is presented in an effort to reduce spatial resolution degradation towards the periphery of the breast. The GATE Monte Carlo Simulation software was utilized to accurately model the system matrix for a breast PET system. A strategy for increasing the count statistics in the system matrix computation and for reducing the system element storage space was used by calculating only a subset of matrix elements and then estimating the rest of the elements by using the geometric symmetry of the cylindrical scanner. To implement this strategy, polar voxel basis functions were used to represent the object, resulting in a block-circulant system matrix. Simulation studies using a breast PET scanner model with ring geometry demonstrated improved contrast at 45% reduced noise level and 1.5 to 3 times resolution performance improvement when compared to MLEM reconstruction using a simple line-integral model. The GATE based system matrix reconstruction technique promises to improve resolution and noise performance and reduce image distortion at FOV periphery compared to line-integral based system matrix reconstruction.

  5. PET in management of breast cancer

    International Nuclear Information System (INIS)

    Lee, Myung-Chul

    2004-01-01

    Full text: PET provides useful information about tumor metabolism enabling accurate visualization of malignant lesions. Approximately 60-80% suspicious lesions on mammography have benign histology and about 10% of breast cancers with palpable mass are not identified in mammography. The key roles of PET technology in breast cancer are in: primary diagnosis, staging, recurrent diseases monitoring and prediction of therapy response. The sensitivity and specificity of FDG-PET for the diagnosis of breast cancer has been reported to be 68-100% and 83-100%, respectively. Considering the increasing number of small breast tumors detected by mammography and false negative results, the clinical relevance of FDG-PET for the primary diagnosis is limited. In selected patients, however, for example with dense breasts, breasts implants, augmented breast or after breast surgery, which can affect the accuracy of mammography, and in cases with equivocal mammography, FDG-PET can provide clinically relevant information. PET accurately determines the extent of disease, including the loco-regional lymph node status. Furthermore, whole-body PET imaging promises a high diagnostic accuracy for detecting recurrent or metastatic breast carcinoma with a high positive predictive value. We studied the usefulness of the FDG-PET in 42 preoperative patients with suspected breast cancer in differentiation of lesions. The diagnostic value of FDG-PET in terms of sensitivity and specificity was 95% and 77% respectively in primary mass while it was 73% and 100% for axillary lymph nodes. PET is much more accurate than other conventional modalities. The sensitivity of FDG-PET for correct staging of axillary nodal status is 84-100%. It has the potential to replace conventional procedures for the staging of distant metastases. We observed the sensitivity and the specificity of FDG-PET to be 96% and 85% to detect distant metastases. FDG-PET may become the method of choice for the early assessment of

  6. Clear-PEM: A PET imaging system dedicated to breast cancer diagnostics

    CERN Document Server

    Abreu, M C; Albuquerque, E; Almeida, F G; Almeida, P; Amaral, P; Auffray, Etiennette; Bento, P; Bruyndonckx, P; Bugalho, R; Carriço, B; Cordeiro, H; Ferreira, M; Ferreira, N C; Gonçalves, F; Lecoq, Paul; Leong, C; Lopes, F; Lousã, P; Luyten, J; Martins, M V; Matela, N; Rato-Mendes, P; Moura, R; Nobre, J; Oliveira, N; Ortigão, C; Peralta, L; Rego, J; Ribeiro, R; Rodrigues, P; Santos, A I; Silva, J C; Silva, M M; Tavernier, Stefaan; Teixeira, I C; Texeira, J P; Trindade, A; Trummer, Julia; Varela, J

    2007-01-01

    The Clear-PEM scanner for positron emission mammography under development is described. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes and readout by a fast low-noise electronic system. A dedicated digital trigger (TGR) and data acquisition (DAQ) system is used for on-line selection of coincidence events with high efficiency, large bandwidth and small dead-time. A specialized gantry allows to perform exams of the breast and of the axilla. In this paper we present results of the measurement of detector modules that integrate the system under construction as well as the imaging performance estimated from Monte Carlo simulated data.

  7. CYBPET: a cylindrical PET system for breast imaging

    Energy Technology Data Exchange (ETDEWEB)

    Karimian, A. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of) and Nuclear Research Center for Agriculture and Medicine (NRCAM-AEOI), P.O. BOX. (31485-498), Karaj, Iran, Islamic Republic of and Department of Experimental Medicine and Pathology, University of Rome, La Sapienza, Rome (Italy)]. E-mail: akarimian@nrcam.org; Thompson, C.J. [Montreal Neurological Institute, McGill University, Montreal QC (Canada); Sarkar, S. [Medical physics Department of Tehran University of Medical Sciences and (RCSTIM), Tehran (Iran, Islamic Republic of); Raisali, G. [Nuclear Research Center for Agriculture and Medicine (NRCAM-AEOI), P.O. BOX. (31485-498), Karaj (Iran, Islamic Republic of); Pani, R. [Department of Experimental Medicine and Pathology, University of Rome La Sapienza, Rome (Italy); Davilu, H. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of); Sardari, D. [Amirkabir University of Technology, Tehran (Iran, Islamic Republic of)

    2005-06-11

    We propose a Cylindrical Breast PET (CYBPET) system for breast imaging with patients in the prone position. An individual pendulous breast is covered by thin plastic to provide reduced pressure fixation and surrounded by the crystals inside the CYBPET ring. Each breast is imaged separately. The rest of the body is shielded properly to minimize the contribution of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET (WB-PET) the simulations of CYBPET and a WB-PET (GE-Advance) for a 10 mm tumor inside the breast with a lesion to background (breast) activity concentration of 6 to 1 were made. The noise effective count rate (NECR) of CYBPET is about twice that of WB-PET at activity concentrations less than 3.1 {mu}Ci/cc. The spatial resolution of CYBPET is better by 25% than the WB-PET.

  8. CYBPET: a cylindrical PET system for breast imaging

    International Nuclear Information System (INIS)

    Karimian, A.; Thompson, C.J.; Sarkar, S.; Raisali, G.; Pani, R.; Davilu, H.; Sardari, D.

    2005-01-01

    We propose a Cylindrical Breast PET (CYBPET) system for breast imaging with patients in the prone position. An individual pendulous breast is covered by thin plastic to provide reduced pressure fixation and surrounded by the crystals inside the CYBPET ring. Each breast is imaged separately. The rest of the body is shielded properly to minimize the contribution of scattered photons from the other breast and the rest of the body. To compare the CYBPET with whole-body PET (WB-PET) the simulations of CYBPET and a WB-PET (GE-Advance) for a 10 mm tumor inside the breast with a lesion to background (breast) activity concentration of 6 to 1 were made. The noise effective count rate (NECR) of CYBPET is about twice that of WB-PET at activity concentrations less than 3.1 μCi/cc. The spatial resolution of CYBPET is better by 25% than the WB-PET

  9. PET imaging in breast cancer

    International Nuclear Information System (INIS)

    Bombardieri, E.; Crippa, F.

    2001-01-01

    The basis of tumour imaging with PET is a specific uptake mechanism of positron emitting radiopharmaceuticals. Among the potential tracers for breast cancer (fluorodeoxyglucose, methionine, tyrosine, fluoro-estradiol, nor-progesterone), 2-deoxy-2-fluoro-D-glucose labelled with fluorine (FDG) is the most widely used radiopharmaceutical because breast cancer is particularly avid of FDG and 18 F has the advantages of the a relatively long physical half-life. Mammography is the first choice examination in studying breast masses, due to its very good performances, an excellent compliance and the best value regarding the cost/effectiveness aspects. The FDG uptake in tissue correlates with the histological grade and potential aggressiveness of breast cancer and this may have prognostic consequences. Besides the evaluation of breast lesions, FDG-PET shows a great efficacy in staging lymph node involvement prior surgery and this could have a great value in loco-regional staging. Whole body PET provides also information with regard to metastasis localizations both in soft tissue and bone, and plays an important clinical role mainly in detecting recurrent metastatic disease. In fact for its metabolic characteristics PET visualizes regions of enhanced metabolic activity and can complete other imaging modalities based on structural anatomic changes. Even though CT and MRI show superior resolution characteristics, it has been demonstrated that PET provides more accurate information in discriminating between viable tumour, fibrotic scar or necrosis. These statements are coming from the examination of more than 2000 breast cancer detection

  10. MRI fused with prone FDG PET/CT improves the primary tumour staging of patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia-Velloso, Maria J.; Ribelles, Maria J.; Rodriguez, Macarena; Sancho, Lidia; Prieto, Elena [Clinica Universidad de Navarra, Department of Nuclear Medicine, Pamplona (Spain); Fernandez-Montero, Alejandro [Clinica Universidad de Navarra, Department of Occupational Medicine, Pamplona (Spain); Santisteban, Marta [Clinica Universidad de Navarra, Department of Oncology, Pamplona (Spain); Rodriguez-Spiteri, Natalia; Martinez-Regueira, Fernando [Clinica Universidad de Navarra, Department of Surgery, Pamplona (Spain); Idoate, Miguel A. [Clinica Universidad de Navarra, Department of Pathology, Pamplona (Spain); Elizalde, Arlette; Pina, Luis J. [Clinica Universidad de Navarra, Department of Radiology, Pamplona (Spain)

    2017-08-15

    Our aim was to evaluate the diagnostic accuracy of magnetic resonance imaging (MRI) fused with prone 2-[fluorine-18]-fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in primary tumour staging of patients with breast cancer. This retrospective study evaluated 45 women with 49 pathologically proven breast carcinomas. MRI and prone PET-CT scans with time-of-flight and point-spread-function reconstruction were performed with the same dedicated breast coil. The studies were assessed by a radiologist and a nuclear medicine physician, and evaluation of fused images was made by consensus. The final diagnosis was based on pathology (90 lesions) or follow-up ≥ 24 months (17 lesions). The study assessed 72 malignant and 35 benign lesions with a median size of 1.8 cm (range 0.3-8.4 cm): 31 focal, nine multifocal and nine multicentric cases. In lesion-by-lesion analysis, sensitivity, specificity, positive and negative predictive values were 97%, 80%, 91% and 93% for MRI, 96%, 71%, 87%, and 89% for prone PET, and 97%. 94%, 97% and 94% for MRI fused with PET. Areas under the curve (AUC) were 0.953, 0.850, and 0.983, respectively (p < 0.01). MRI fused with FDG-PET is more accurate than FDG-PET in primary tumour staging of breast cancer patients and increases the specificity of MRI. (orig.)

  11. Contrast-enhanced dedicated breast CT detection of invasive breast cancer preceding mammographic diagnosis

    Directory of Open Access Journals (Sweden)

    Nicolas D. Prionas, MD, PhD

    2015-01-01

    Full Text Available Dedicated breast computed tomography (bCT generates high-resolution, three-dimensional images of the pendent uncompressed breast. Intravenous iodinated contrast during bCT provides additional physiologic information. In this case, a 10.0-mm invasive ductal carcinoma was visualized using contrast-enhanced breast CT one year before mammographic detection. Mammography four months before bCT was negative. The bCT contrast enhancement pattern closely matched the dynamic contrast-enhanced MRI obtained after diagnosis. Lesion enhancement at contrast-enhanced breast CT matched previously published enhancement values of breast cancer. Contrast-enhanced dedicated bCT provided high-resolution tomographic images and physiologic contrast enhancement data that facilitated the detection of an early breast cancer.

  12. Evaluation of a Hanging-Breast PET System for Primary Tumor Visualization in Patients With Stage I-III Breast Cancer: Comparison With Standard PET/CT.

    Science.gov (United States)

    Teixeira, Suzana C; Rebolleda, José Ferrér; Koolen, Bas B; Wesseling, Jelle; Jurado, Raúl Sánchez; Stokkel, Marcel P M; Del Puig Cózar Santiago, María; van der Noort, Vincent; Rutgers, Emiel J Th; Valdés Olmos, Renato A

    2016-06-01

    The purposes of this study were to evaluate the performance of a mammography with molecular imaging PET (MAMMI-PET) system for breast imaging in the hanging-breast position for the visualization of primary breast cancer lesions and to compare this method with whole-body PET/CT. Between March 2011 and March 2014, a prospective evaluation included women with one or more histologically confirmed primary breast cancer lesions (index lesions). After injection of 180-240 MBq of (18)F-FDG, whole-body PET/CT and MAMMI-PET acquisitions were performed, index lesions were scored 0, 1, or 2 for FDG uptake relative to background. Detection and FDG uptake were compared by breast length, maximal tumor diameter, affected breast quadrants, tumor grade, and histologic and immunologic sub-types. Finally, the two PET modalities were compared for detection of index lesions. For 234 index lesions (diameter, 5-170 mm), the overall sensitivity was 88.9% for MAMMI-PET and 91% for PET/CT (p = 0.61). Twenty-three (9.8%) index lesions located too close to the pectoral muscle were missed with MAMMI-PET, and 20 index lesions were missed with PET/CT. Lesion visibility on MAMMI-PET images was influenced by tumor grade (p = 0.034) but not by cancer subtype (p = 0.65). Although in an overall evaluation MAMMI-PET was not superior to PET/CT, MAMMI-PET does have higher sensitivity for primary breast cancer lesions within the scanning range of the device. Optimization of the positioning device may increase visualization of the most dorsal lesions.

  13. Improved detection of breast cancer on FDG-PET cancer screening using breast positioning device

    International Nuclear Information System (INIS)

    Kaida, Hayato; Ishibashi, Masatoshi; Fujii, Teruhiko; Kurata, Seiji; Ogo, Etsuyo; Hayabuchi, Naofumi; Tanaka, Maki

    2008-01-01

    The aim of this study was to investigate the detection rate of breast cancer by positron emission tomography cancer screening using a breast positioning device. Between January 2004 and January 2006, 1,498 healthy asymptomatic individuals underwent cancer screening by fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) at our institution; 660 of 1498 asymptomatic healthy women underwent breast PET imaging in the prone position using the breast positioning device to examine the mammary glands in addition to whole-body PET imaging. All subjects that showed abnormal 18 F-FDG uptake in the mammary glands were referred for further examination or surgery at our institution or a local hospital. Our data were compared with the histopathological findings or findings of other imaging modalities in our institution and replies from the doctors at another hospital. Of the 660 participants, 7 (1.06%) were found to have breast cancers at a curable stage. All the seven cancers were detected by breast PET imaging, but only five of these were detected by whole-body PET imaging; the other two were detected by breast PET imaging using the breast positioning device. In cancer screening, prone breast imaging using a positioning device may help to improve the detection rate of breast cancer. However, overall cancer including mammography and ultrasonography screening should be performed to investigate the false-negative cases and reduce false-positive cases. The effectiveness of prone breast PET imaging in cancer screening should be investigated using a much larger number of cases in the near future. (author)

  14. Breast hemangioma mimicking metastasis at PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Sabas Carlos [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil). Fac. de Medicina; Silva, Jucelia Saraiva e [MedImagem, Teresina, PI (Brazil). Clinica Medica; Madeira, Eveline Brandao; Franca, Julio Cesar Queiroz de; Martins Filho, Sebastiao Nunes [Universidade Federal do Piaui (UFPI), Teresina, PI (Brazil)

    2011-11-15

    Breast hemangioma is a rare benign tumor that presents either absent or low {sup 18}F-fluoro-2-deoxy-D-glucose (FDG) uptake at positron emission tomography (PET). The authors report the case of a breast nodule pathologically compatible with hemangioma in a woman whose PET-scan has demonstrated increased FDG uptake (simulating a malignant tumor). A brief review of factors leading to false positive and false negative PET results is also undertaken. (author)

  15. Gamma-camera 18F-FDG PET in diagnosis and staging of patients presenting with suspected lung cancer and comparison with dedicated PET

    DEFF Research Database (Denmark)

    Oturai, Peter S; Mortensen, Jann; Enevoldsen, Henriette

    2004-01-01

    It is not clear whether high-quality coincidence gamma-PET (gPET) cameras can provide clinical data comparable with data obtained with dedicated PET (dPET) cameras in the primary diagnostic work-up of patients with suspected lung cancer. This study focuses on 2 main issues: direct comparison...

  16. Scintillator performance considerations for dedicated breast computed tomography

    Science.gov (United States)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew

    2017-09-01

    Dedicated breast computed tomography (BCT) is an emerging clinical modality that can eliminate tissue superposition and has the potential for improved sensitivity and specificity for breast cancer detection and diagnosis. It is performed without physical compression of the breast. Most of the dedicated BCT systems use large-area detectors operating in cone-beam geometry and are referred to as cone-beam breast CT (CBBCT) systems. The large-area detectors in CBBCT systems are energy-integrating, indirect-type detectors employing a scintillator that converts x-ray photons to light, followed by detection of optical photons. A key consideration that determines the image quality achieved by such CBBCT systems is the choice of scintillator and its performance characteristics. In this work, a framework for analyzing the impact of the scintillator on CBBCT performance and its use for task-specific optimization of CBBCT imaging performance is described.

  17. FDG-PET in monitoring therapy of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Biersack, H J; Bender, H; Palmedo, H [Department of Nuclear Medicine, University Hospital Bonn, Sigmund-Freud-Strasse 25, 53127, Bonn (Germany)

    2004-06-01

    Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) has been used successfully for the staging and re-staging of breast cancer. Another significant indication is the evaluation of therapy response. Only limited data are available on the use of FDG-PET in breast cancer after radiation therapy. The same holds true for chemotherapy. Only the therapy response in locally advanced breast cancer after chemotherapy has been investigated thoroughly. Histopathological response could be predicted with an accuracy of 88-91% after the first and second courses of therapy. A quantitative evaluation is, of course, a prerequisite when FDG-PET is used for therapy monitoring. Only a small number of studies have focussed on hormone therapy. In this context, a flare phenomenon with increasing standardised uptake values after initiation of tamoxifen therapy has been observed. More prospective multicentre trials will be needed to make FDG-PET a powerful tool in monitoring chemotherapy in breast cancer. (orig.)

  18. FDG-PET in monitoring therapy of breast cancer

    International Nuclear Information System (INIS)

    Biersack, H.J.; Bender, H.; Palmedo, H.

    2004-01-01

    Fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) has been used successfully for the staging and re-staging of breast cancer. Another significant indication is the evaluation of therapy response. Only limited data are available on the use of FDG-PET in breast cancer after radiation therapy. The same holds true for chemotherapy. Only the therapy response in locally advanced breast cancer after chemotherapy has been investigated thoroughly. Histopathological response could be predicted with an accuracy of 88-91% after the first and second courses of therapy. A quantitative evaluation is, of course, a prerequisite when FDG-PET is used for therapy monitoring. Only a small number of studies have focussed on hormone therapy. In this context, a flare phenomenon with increasing standardised uptake values after initiation of tamoxifen therapy has been observed. More prospective multicentre trials will be needed to make FDG-PET a powerful tool in monitoring chemotherapy in breast cancer. (orig.)

  19. FDG-PET/CT in the diagnosis of recurrent breast cancer

    International Nuclear Information System (INIS)

    Murakami, Ryusuke; Kumita, Shin-ichiro; Yoshida, Tamiko; Ishihara, Keiichi; Kiriyama, Tomonari; Hakozaki, Kenta; Yanagihara, Keiko; Lida, Shinya; Tsuchiya, Shin-ichi

    2012-01-01

    Background. An advantage of PET/CT has been demonstrated for diagnosis of several tumor entities. In patients with breast cancer, early diagnosis and accurate restaging of recurrence after surgery is important for selection of the most appropriate therapeutic strategy. Purpose. To evaluate the accuracy of integrated positron emission tomography and computed tomography (PET/CT) using 18F-fluorodeoxyglucose (FDG), for follow-up of patients with suspected recurrent breast cancer. Material and Methods. Forty-seven patients with suspected recurrent breast cancer underwent PET/CT. The PET and PET/CT images were interpreted without knowledge of the results of other diagnostic modalities, and compared with each other with reference to the final diagnosis. Results. Twenty-five (53%) patients suffered tumor recurrence. The overall sensitivity, specificity, positive predictive value (PPV), negative predictive value (NPV), and accuracy of PET/CT were 96%, 91%, 92%, 95%, and 94%, respectively. In comparison with PET, PET/CT had a higher sensitivity and accuracy (96% vs. 80% and 94% vs. 81%, respectively). The difference in diagnostic accuracy between PET/CT and PET was significant (P < 0.05). Conclusion. The present findings indicate that PET/CT is an accurate, sensitive and reliable modality for screening and detection of breast cancer recurrence. PET/CT appears to be an effective surveillance tool, as it is able to cover the whole body in a single procedure and shows good performance

  20. Study of the personal radiation dose received by nuclear medicine technologists working in a dedicated PET centre

    International Nuclear Information System (INIS)

    Robinson, C.N.; Wallace, A.B.; Young, A.B.; Ibbetson, V.J.

    2005-01-01

    The use of dedicated PET scanners is becoming more widespread throughout Australia and the world. PET imaging utilises short-lived (-108 min), high-energy (511 keV) gamma-ray emitters, that could result in a high radiation dose being received by staff. As part of a larger staff and area monitoring project, this paper discusses the personal dose equivalent, H p (10), received by PET staff working in a dedicated PET centre. The typical H (10) received by staff was approximately 31 μSv. The average daily administered activity to patients at Austin Health was 1280 MBq

  1. Initial clinical test of a breast-PET scanner

    International Nuclear Information System (INIS)

    Raylman, Raymond R.; Koren, Courtney; Schreiman, Judith S.; Majewski, Stan; Marano, Gary D.; Abraham, Jame; Kurian, Sobha; Hazard, Hannah; Filburn, Shannon

    2011-01-01

    The goal of this initial clinical study was to test a new positron emission/tomography imager and biopsy system (PEM/PET) in a small group of selected subjects to assess its clinical imaging capabilities. Specifically, the main task of this study is to determine whether the new system can successfully be used to produce images of known breast cancer and compare them to those acquired by standard techniques. The PEM/PET system consists of two pairs of rotating radiation detectors located beneath a patient table. The scanner has a spatial resolution of ∼2 mm in all three dimensions. The subjects consisted of five patients diagnosed with locally advanced breast cancer ranging in age from 40 to 55 years old scheduled for pre-treatment, conventional whole body PET imaging with F-18 Fluorodeoxyglucose (FDG). The primary lesions were at least 2 cm in diameter. The images from the PEM/PET system demonstrated that this system is capable of identifying some lesions not visible in standard mammograms. Furthermore, while the relatively large lesions imaged in this study where all visualised by a standard whole body PET/CT scanner, some of the morphology of the tumours (ductal infiltration, for example) was better defined with the PEM/PET system. Significantly, these images were obtained immediately following a standard whole body PET scan. The initial testing of the new PEM/PET system demonstrated that the new system is capable of producing good quality breast-PET images compared standard methods.

  2. Breast cancer detection using high-resolution breast PET compared to whole-body PET or PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kalinyak, Judith E. [Naviscan Inc., San Diego, CA (United States); Berg, Wendie A. [University of Pittsburgh School of Medicine, Magee-Womens Hospital, Pittsburgh, PA (United States); Schilling, Kathy [Boca Raton Regional Hospital, Boca Raton, FL (United States); Madsen, Kathleen S. [Certus International, Inc., St. Louis, MO (United States); Narayanan, Deepa [Naviscan Inc., San Diego, CA (United States); National Cancer Institute, Bethesda, MD (United States); Tartar, Marie [Scripps Clinic, Scripps Green Hospital, La Jolla, CA (United States)

    2014-02-15

    To compare the performance characteristics of positron emission mammography (PEM) with those of whole-body PET (WBPET) and PET/CT in women with newly diagnosed breast cancer. A total of 178 women consented to PEM for presurgical planning in an IRB-approved protocol and also underwent either WBPET (n = 69) or PET/CT (n = 109) imaging, as per usual care at three centers. Tumor detection sensitivity, positive predictive values, and {sup 18}F-fluorodeoxyglucose (FDG) uptake were compared between the modalities. The effects of tumor size, type, and grade on detection were examined. The chi-squared or Fisher's exact tests were used to compare distributions between groups, and McNemar's test was used to compare distributions for paired data within subject groups, i.e. PEM versus WBPET or PEM versus PET/CT. The mean age of the women was 59 ± 12 years (median 60 years, range 26-89 years), with a mean invasive index tumor size of 1.6 ± 0.8 cm (median 1.5 cm, range 0.5-4.0 cm). PEM detected more index tumors (61/66, 92 %) than WBPET (37/66, 56 %; p < 0.001) or PET/CT (95/109, 87 % vs. 104/109, 95 % for PEM; p < 0.029). Sensitivity for the detection of additional ipsilateral malignancies was also greater with PEM (7/15, 47 %) than with WBPET (1/15, 6.7 %; p = 0.014) or PET/CT (3/23, 13 % vs. 13/23, 57 % for PEM; p = 0.003). Index tumor detection decreased with decreasing invasive tumor size for both WBPET (p = 0.002) and PET/CT (p < 0.001); PEM was not significantly affected (p = 0.20). FDG uptake, quantified in terms of maximum PEM uptake value, was lowest in ductal carcinoma in situ (median 1.5, range 0.7-3.0) and invasive lobular carcinoma (median 1.5, range 0.7-3.4), and highest in grade III invasive ductal carcinoma (median 3.1, range 1.4-12.9). PEM was more sensitive than either WBPET or PET/CT in showing index and additional ipsilateral breast tumors and remained highly sensitive for tumors smaller than 1 cm. (orig.)

  3. A minimum spanning forest based classification method for dedicated breast CT images

    International Nuclear Information System (INIS)

    Pike, Robert; Sechopoulos, Ioannis; Fei, Baowei

    2015-01-01

    Purpose: To develop and test an automated algorithm to classify different types of tissue in dedicated breast CT images. Methods: Images of a single breast of five different patients were acquired with a dedicated breast CT clinical prototype. The breast CT images were processed by a multiscale bilateral filter to reduce noise while keeping edge information and were corrected to overcome cupping artifacts. As skin and glandular tissue have similar CT values on breast CT images, morphologic processing is used to identify the skin based on its position information. A support vector machine (SVM) is trained and the resulting model used to create a pixelwise classification map of fat and glandular tissue. By combining the results of the skin mask with the SVM results, the breast tissue is classified as skin, fat, and glandular tissue. This map is then used to identify markers for a minimum spanning forest that is grown to segment the image using spatial and intensity information. To evaluate the authors’ classification method, they use DICE overlap ratios to compare the results of the automated classification to those obtained by manual segmentation on five patient images. Results: Comparison between the automatic and the manual segmentation shows that the minimum spanning forest based classification method was able to successfully classify dedicated breast CT image with average DICE ratios of 96.9%, 89.8%, and 89.5% for fat, glandular, and skin tissue, respectively. Conclusions: A 2D minimum spanning forest based classification method was proposed and evaluated for classifying the fat, skin, and glandular tissue in dedicated breast CT images. The classification method can be used for dense breast tissue quantification, radiation dose assessment, and other applications in breast imaging

  4. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    Science.gov (United States)

    Moliner, L.; Correcher, C.; González, A. J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M. J.; Sánchez, F.; Soriano, A.; Vidal, L. F.; Benlloch, J. M.

    2013-02-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality.

  5. Implementation and analysis of list mode algorithm using tubes of response on a dedicated brain and breast PET

    International Nuclear Information System (INIS)

    Moliner, L.; Correcher, C.; González, A.J.; Conde, P.; Hernández, L.; Orero, A.; Rodríguez-Álvarez, M.J.; Sánchez, F.; Soriano, A.; Vidal, L.F.; Benlloch, J.M.

    2013-01-01

    In this work we present an innovative algorithm for the reconstruction of PET images based on the List-Mode (LM) technique which improves their spatial resolution compared to results obtained with current MLEM algorithms. This study appears as a part of a large project with the aim of improving diagnosis in early Alzheimer disease stages by means of a newly developed hybrid PET-MR insert. At the present, Alzheimer is the most relevant neurodegenerative disease and the best way to apply an effective treatment is its early diagnosis. The PET device will consist of several monolithic LYSO crystals coupled to SiPM detectors. Monolithic crystals can reduce scanner costs with the advantage to enable implementation of very small virtual pixels in their geometry. This is especially useful for LM reconstruction algorithms, since they do not need a pre-calculated system matrix. We have developed an LM algorithm which has been initially tested with a large aperture (186 mm) breast PET system. Such an algorithm instead of using the common lines of response, incorporates a novel calculation of tubes of response. The new approach improves the volumetric spatial resolution about a factor 2 at the border of the field of view when compared with traditionally used MLEM algorithm. Moreover, it has also shown to decrease the image noise, thus increasing the image quality

  6. Preoperative PET/CT in early-stage breast cancer

    DEFF Research Database (Denmark)

    Bernsdorf, M; Berthelsen, A K; Timmermans-Wielenga, Vera

    2012-01-01

    The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer.......The aim of this study was to assess the diagnostic and therapeutic impact of preoperative positron emission tomography and computed tomography (PET/CT) in the initial staging of patients with early-stage breast cancer....

  7. PET/CT and dedicated PET in breast cancer: Implications for classification, staging, and response monitoring

    NARCIS (Netherlands)

    Koolen, B.B.

    2013-01-01

    De PET-CT, een scan die gebruik maakt van radioactiviteit om tumoren in beeld te brengen, is een zinvol instrument voor beeldvorming van patiënten met borstkanker, met name van patiënten met een tumor groter dan drie centimeter of tumor-positieve lymfeklieren. De PET-CT is vooral van waarde voor de

  8. Staging performance of whole-body DWI, PET/CT and PET/MRI in invasive ductal carcinoma of the breast.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Daye, Dania; Signore, Alberto; Iannace, Carlo; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Filomena, Mazzeo; Mansi, Luigi; Soricelli, Andrea; Salvatore, Marco; Fuin, Niccolo; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-07-01

    The aim of the present study was to evaluate the performance of whole-body diffusion-weighted imaging (WB-DWI), whole-body positron emission tomography with computed tomography (WB-PET/CT), and whole-body positron emission tomography with magnetic resonance imaging (WB-PET/MRI) in staging patients with untreated invasive ductal carcinoma of the breast. Fifty-one women with newly diagnosed invasive ductal carcinoma of the breast underwent WB-DWI, WB-PET/CT and WB-PET/MRI before treatment. A radiologist and a nuclear medicine physician reviewed in consensus the images from the three modalities and searched for occurrence, number and location of metastases. Final staging, according to each technique, was compared. Pathology and imaging follow-up were used as the reference. WB-DWI, WB-PET/CT and WB-PET/MRI correctly and concordantly staged 33/51 patients: stage IIA in 7 patients, stage IIB in 8 patients, stage IIIC in 4 patients and stage IV in 14 patients. WB-DWI, WB-PET/CT and WB-PET/MRI incorrectly and concordantly staged 1/51 patient as stage IV instead of IIIA. Discordant staging was reported in 17/51 patients. WB-PET/MRI resulted in improved staging when compared to WB-PET/CT (50 correctly staged on WB-PET/MRI vs. 38 correctly staged on WB-PET/CT; McNemar's test; p<0.01). Comparing the performance of WB-PET/MRI and WB-DWI (43 correct) did not reveal a statistically significant difference (McNemar test, p=0.14). WB-PET/MRI is more accurate in the initial staging of breast cancer than WB-DWI and WB-PET/CT, however, the discrepancies between WB-PET/MRI and WB-DWI were not statistically significant. When available, WB-PET/MRI should be considered for staging patient with invasive ductal breast carcinoma.

  9. Performance of FDG PET/CT in the clinical management of breast cancer.

    Science.gov (United States)

    Groheux, David; Espié, Marc; Giacchetti, Sylvie; Hindié, Elif

    2013-02-01

    In this analysis, the role of metabolic imaging with fluorine 18 fluorodeoxyglucose (FDG) in breast cancer is reviewed. The analysis was limited to recent works by using state-of-the-art positron emission tomography (PET)/computed tomography (CT) technology. The strengths and limitations of FDG PET/CT are examined in various clinical settings, and the following questions are answered: Is FDG PET/CT useful to differentiate malignant from benign breast lesions? Can FDG PET/CT replace sentinel node biopsy for axillary staging? What is the role of FDG PET/CT in initial staging of inflammatory or locally advanced breast cancer? What is the role of FDG PET/CT in initial staging of clinical stage IIA and IIB and primary operable stage IIIA breast cancer? How does FDG PET/CT compare with conventional techniques in the restaging of cancer in patients who are suspected of having disease recurrence? What is the role of FDG PET/CT in the assessment of early response to neoadjuvant therapy and of response to therapy for metastatic disease? Some recommendations for clinical practice are given.

  10. Clinical Significance of Focal Breast Lesions Incidentally Identified by 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Cho, Young Seok; Choi, Joon Young; Lee, Su Jin; Hyun, Seung Hyup; Lee, Ji Young; Choi, Yong; Choe, Yearn Seong; Lee, Kyung Han; Kim, Byung Tae

    2008-01-01

    We evaluated the incidence and malignant risk of focal breast lesions incidentally detected by 18 F-FDG PET/CT. Various PET/CT findings of the breast lesions were also analyzed to improve the differentiation between benign from malignant focal breast lesions. The subjects were 3,768 consecutive 18 F-FDG PET/CT exams performed in adult females without a history of breast cancer. A focal breast lesion was defined as a focal 18 F-FDG uptake or a focal nodular lesion on CT image irrespective of 18 F-FDG uptake in the breasts. The maximum SUV and CT pattern of focal breast lesions were evaluated, and were compared with final diagnosis. The incidence of focal breast lesions on PET/CT in adult female subjects was 1.4% (58 lesions in 53 subjects). In finally confirmed 53 lesions of 48 subjects, 11 lesions of 8 subjects (20.8%) were proven to be malignant. When the PET/CT patterns suggesting benignancy (maximum attenuation value > 75 HU or 20) were added as diagnostic criteria of PET/CT to differentiate benign from malignant breast lesions along with maximum SUV, the area under ROC curve of PET/CT was significantly increased compared with maximum SUV alone (0.680±0.093 vs. 0.786±0.076, p 18 F-FDG PET/CT is not low, deserving further diagnostic confirmation. Image interpretation considering both 18 F-FDG uptake and PET/CT pattern may be helpful to improve the differentiation from malignant and benign focal breast lesion

  11. Fully automated deformable registration of breast DCE-MRI and PET/CT

    Science.gov (United States)

    Dmitriev, I. D.; Loo, C. E.; Vogel, W. V.; Pengel, K. E.; Gilhuijs, K. G. A.

    2013-02-01

    Accurate characterization of breast tumors is important for the appropriate selection of therapy and monitoring of the response. For this purpose breast imaging and tissue biopsy are important aspects. In this study, a fully automated method for deformable registration of DCE-MRI and PET/CT of the breast is presented. The registration is performed using the CT component of the PET/CT and the pre-contrast T1-weighted non-fat suppressed MRI. Comparable patient setup protocols were used during the MRI and PET examinations in order to avoid having to make assumptions of biomedical properties of the breast during and after the application of chemotherapy. The registration uses a multi-resolution approach to speed up the process and to minimize the probability of converging to local minima. The validation was performed on 140 breasts (70 patients). From a total number of registration cases, 94.2% of the breasts were aligned within 4.0 mm accuracy (1 PET voxel). Fused information may be beneficial to obtain representative biopsy samples, which in turn will benefit the treatment of the patient.

  12. The application value of PET-CT in the diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Li Haitao

    2005-01-01

    Breast cancer is the most common malignancy in women in most of countries. During the past decades, the application of PET with 18 f-fluoro-2-deoxy-D-glocuse ( 18 F-FDG) has remarkably improved the management of breast cancer. Nevertheless, due to anatomical localisation of 18 F-FDG uptake was difficult, the clinical interpretation of 18 F-FDG PET scan could not be exactly. A novel combined PET-CT system has largely improved the capacity of sensitivity and specificity in the diagnosis of breast cancer. In this artiacal we focus on the application value of PET-CT to breast cancer diagnosis, with respect to dissease re-staging, treatment monitoring, preoperative staging and radiotherapy planning. (authors)

  13. FDG-PET/CT detection of very early breast cancer in women with breast microcalcification lesions found in mammography screening

    International Nuclear Information System (INIS)

    Peng, Nang-Jing; Chou, Chen-Pin; Pan, Huay-Ben; Chang, Tsung-Hsien; Hu, Chin; Chiu, Yu-Li; Fu, Ting-Ying; Chang, Hong-Tai

    2015-01-01

    To assess the efficacy of positron emission tomography/computed tomography with the glucose analogue 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG-PET/CT) in Taiwanese women with early breast cancer detected by mammography screening. Dual-time-point imaging of whole-body supine and breast prone scans using FDG-PET/CT were performed sequentially in the pre-operative stage. A total of 11,849 patients underwent screening mammography, of whom 1,209 (10.2%) displayed positive results. After further investigation, 54 patients underwent FDG-PET/CT. Post-operative pathology examinations revealed malignancies in 26 lesions, including invasive breast cancer in 11 cases and non-invasive breast cancer in 15 cases, as well as benign disease in 30 lesions. The FDG-PET/CT findings from the whole-body scans were positive for 9 of 11 invasive breast cancers (81.8%) and 3 of 15 non-invasive cancers (20%), and they were negative for all benign lesions. The sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) of FDG-PET/CT with whole-body supine imaging were 46.2%, 100%, 100% and 68.2%, respectively. Breast prone imaging revealed another patient with ductal carcinoma in situ, increasing the sensitivity to 50%. Importantly, positive PET findings were significantly correlated with tumour histology (P = 0.006), tumour size (P = 0.039) and Ki-67 expression (P = 0.011). FDG-PET/CT with whole-body scanning demonstrated high sensitivity to invasive breast cancer, limited sensitivity to non-invasive breast cancer, and high specificity for breast cancer. FDG-PET/CT might be useful for differentiating tumour invasiveness. However, the good PPV but poor NPV do not allow the physician to discard the biopsy.

  14. A dedicated tool for PET scanner simulations using FLUKA

    International Nuclear Information System (INIS)

    Ortega, P.G.; Boehlen, T.T.; Cerutti, F.; Chin, M.P.W.; Ferrari, A.; Mancini, C.; Vlachoudis, V.; Mairani, A.; Sala, Paola R.

    2013-06-01

    Positron emission tomography (PET) is a well-established medical imaging technique. It is based on the detection of pairs of annihilation gamma rays from a beta+-emitting radionuclide, usually inoculated in the body via a biologically active molecule. Apart from its wide-spread use for clinical diagnosis, new applications are proposed. This includes notably the usage of PET for treatment monitoring of radiation therapy with protons and ions. PET is currently the only available technique for non-invasive monitoring of ion beam dose delivery, which was tested in several clinical pilot studies. For hadrontherapy, the distribution of positron emitters, produced by the ion beam, can be analyzed to verify the correct treatment delivery. The adaptation of previous PET scanners to new environments and the necessity of more precise diagnostics by better image quality triggered the development of new PET scanner designs. The use of Monte Carlo (MC) codes is essential in the early stages of the scanner design to simulate the transport of particles and nuclear interactions from therapeutic ion beams or radioisotopes and to predict radiation fields in tissues and radiation emerging from the patient. In particular, range verification using PET is based on the comparison of detected and simulated activity distributions. The accuracy of the MC code for the relevant physics processes is obviously essential for such applications. In this work we present new developments of the physics models with importance for PET monitoring and integrated tools for PET scanner simulations for FLUKA, a fully-integrated MC particle-transport code, which is widely used for an extended range of applications (accelerator shielding, detector and target design, calorimetry, activation, dosimetry, medical physics, radiobiology, ...). The developed tools include a PET scanner geometry builder and a dedicated scoring routine for coincident event determination. The geometry builder allows the efficient

  15. Association of pharmacokinetic and metabolic parameters derived using simultaneous PET/MRI: Initial findings and impact on response evaluation in breast cancer.

    Science.gov (United States)

    Jena, Amarnath; Taneja, Sangeeta; Singh, Aru; Negi, Pradeep; Mehta, Shashi Bhushan; Ahuja, Aashim; Singhal, Manish; Sarin, Ramesh

    2017-07-01

    To study relationships among pharmacokinetic and 18 F-fluorodeoxyglucose ( 18 F-FDG) PET parameters obtained through simultaneous PET/MRI in breast cancer patients and evaluate their combined potential for response evaluation. The study included 41 breast cancer patients for correlation study and 9 patients (pre and post therapy) for response evaluation. All patients underwent simultaneous PET/MRI with dedicated breast imaging. Pharmacokinetic parameters and PET parameters for tumor were derived using an in- house developed and vendor provided softwares respectively. Relationships between SUV and pharmacokinetic parameters and clinical as well as histopathologic parameters were evaluated using Spearman correlation analysis. Response to chemotherapy was derived as percentage reduction in size and in parameters post therapy. Significant correlations were observed between SUVmean, max, peak, TLG with K trans (ρ=0.446, 0.417, 0.491, 0.430; p≤0.01); with Kep(ρ=0.303, ρ=0.315, ρ=0.319; p≤0.05); and with iAUC(ρ=0.401, ρ=0.410, ρ=0.379; p≤0.05, p≤0.01). The ratio of ve/iAUC showed significant negative correlation to SUVmean, max, peak and TLG (ρ=0.420, 0.446, 0.443, 0.426; p≤0.01). Ability of SUV as well as pharmacokinetic parameters to predict response to therapy matched the RECIST criteria in 9 out of 11 lesions in 9 patients. Maximum post therapy quantitative reduction was observed in SUVpeak, TLG and K trans . Simultaneous PET/MRI enables illustration of close interactions between glucose metabolism and pharmacokinetic parameters in breast cancer patients and potential of their simultaneity in response assessment to therapy. Copyright © 2017 Elsevier B.V. All rights reserved.

  16. PET with a dual-head coincidence gamma camera in head and neck cancer: A comparison with computed tomography and dedicated PET

    International Nuclear Information System (INIS)

    Zimny, M.

    2001-01-01

    Positron emission tomography with 18 F-fluoro-deoxyglucose (FDG PET) is a promising imaging tool for detecting and staging of primary or recurrent head and neck cancer. The aim of this study was to evaluate a dual-head gamma camera modified for coincidence detection (KGK-PET) in comparison to computed tomography (CT) and dedicated PET (dPET). 50 patients with known or suspected primary or recurrent head and neck cancer were enrolled. 32 patients underwent KGK-PET and dPET using a one-day protocol. The sensitivity for the detection of primary/ recurrent head and neck cancer for KGK-PET and CT was 80% and 54%, respectively, specificity was 73% and 82%, respectively. The sensitivity and specificity for the detection of lymph node metastases based on neck sides with KGK-PET was 71% (CT: 65%) and 88% (CT: 89%) respectively. In comparison to dPET, KGK-PET revealed concordant results in 32/32 patients with respect to primary tumor/recurrent disease and in 55/60 evaluated neck sides. All involved neck sides that were missed by KGK-PET were also negative with dPET. These results indicate that in patients with head and neck cancer KGK-PET reveals information, that are similar to dPET and complementary to CT. (orig.) [de

  17. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI

    International Nuclear Information System (INIS)

    Pinker, K.; Marino, M.A.; Meyer-Baese, A.; Helbich, T.H.

    2016-01-01

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ( 1 H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ( 23 Na MRI), phosphorus spectroscopy ( 31 P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [de

  18. Dual-time FDG-PET/CT in patients with potential breast cancer recurrence

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; Gerke, Oke

    Dual-time FDG-PET/CT in patients with potential breast cancer recurrence: head-to-head comparison with CT and bonescintigraphy......Dual-time FDG-PET/CT in patients with potential breast cancer recurrence: head-to-head comparison with CT and bonescintigraphy...

  19. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas

    International Nuclear Information System (INIS)

    Bitencourt, Almir Galvao Vieira; Lima, Eduardo Nobrega Pereira; Chojniak, Rubens; Marques, Elvira Ferreira; Souza, Juliana Alves de; Graziano, Luciana; Andrade, Wesley Pereira; Osorio, Cynthia Aparecida Bueno de Toledo

    2014-01-01

    Objective: to correlate the results of 18 F-fluoro-2-deoxy-D-glucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and methods: cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results: the authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of 18 F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion: PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas. (author)

  20. 18F-FDG PET/CT in breast cancer: Evidence-based recommendations in initial staging.

    Science.gov (United States)

    Caresia Aroztegui, Ana Paula; García Vicente, Ana María; Alvarez Ruiz, Soledad; Delgado Bolton, Roberto Carlos; Orcajo Rincon, Javier; Garcia Garzon, Jose Ramon; de Arcocha Torres, Maria; Garcia-Velloso, Maria Jose

    2017-10-01

    Current guidelines do not systematically recommend 18F-FDG PET/CT for breast cancer staging; and the recommendations and level of evidence supporting its use in different groups of patients vary among guidelines. This review summarizes the evidence about the role of 18F-FDG PET/CT in breast cancer staging and the therapeutic and prognostic impact accumulated in the last decade. Other related aspects, such as the association of metabolic information with biology and prognosis are considered and evidence-based recommendations for the use of 18F-FDG PET/CT in breast cancer staging are offered. We systematically searched MEDLINE for articles reporting studies with at least 30 patients related to clinical questions following the Problem/Population, Intervention, Comparison, and Outcome framework. We critically reviewed the selected articles and elaborated evidence tables structuring the summarized information into methodology, results, and limitations. The level of evidence and the grades of recommendation for the use of 18F-FDG PET/CT in different contexts are summarized. Level III evidence supports the use of 18F-FDG PET/CT for initial staging in patients with recently diagnosed breast cancer; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a weak recommendation in this population. In patients with locally advanced breast cancer, level II evidence supports the use of 18F-FDG PET/CT for initial staging; the diagnostic and therapeutic impact of the 18F-FDG PET/CT findings is sufficient for a strong recommendation in this population. In patients with recently diagnosed breast cancer, the metabolic information from baseline 18F-FDG PET/CT is associated with tumor biology and has prognostic implications, supported by level II evidence. In conclusion, 18F-FDG PET/CT is not recommended for staging all patients with early breast cancer, although evidence of improved regional and systemic staging supports its use in locally advanced

  1. Personalized estimates of radiation dose from dedicated breast CT in a diagnostic population and comparison with diagnostic mammography

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; O'Connell, Avice M; Conover, David L

    2013-01-01

    This study retrospectively analyzed the mean glandular dose (MGD) to 133 breasts from 132 subjects, all women, who participated in a clinical trial evaluating dedicated breast CT in a diagnostic population. The clinical trial was conducted in adherence to a protocol approved by institutional review boards and the study participants provided written informed consent. Individual estimates of MGD to each breast from dedicated breast CT was obtained by combining x-ray beam characteristics with estimates of breast dimensions and fibroglandular fraction from volumetric breast CT images, and using normalized glandular dose coefficients. For each study participant and for the breast corresponding to that imaged with breast CT, an estimate of the MGD from diagnostic mammography (including supplemental views) was obtained from the DICOM image headers for comparison. This estimate uses normalized glandular dose coefficients corresponding to a breast with 50% fibroglandular weight fraction. The median fibroglandular weight fraction for the study cohort determined from volumetric breast CT images was 15%. Hence, the MGD from diagnostic mammography was corrected to be representative of the study cohort. Individualized estimates of MGD from breast CT ranged from 5.7 to 27.8 mGy. Corresponding to the breasts imaged with breast CT, the MGD from diagnostic mammography ranged from 2.6 to 31.6 mGy. The mean (± inter-breast SD) and the median MGD (mGy) from dedicated breast CT exam were 13.9 ± 4.6 and 12.6, respectively. For the corresponding breasts, the mean (± inter-breast SD) and the median MGD (mGy) from diagnostic mammography were 12.4 ± 6.3 and 11.1, respectively. Statistical analysis indicated that at the 0.05 level, the distributions of MGD from dedicated breast CT and diagnostic mammography were significantly different (Wilcoxon signed ranks test, p = 0.007). While the interquartile range and the range (maximum–minimum) of MGD from dedicated breast CT was lower than

  2. PET-CT in the evaluation of metastatic breast cancer

    International Nuclear Information System (INIS)

    Sullivan, A.M.; Fulham, M.J.

    2005-01-01

    A 44-year-old woman underwent two PET-CT scans for the evaluation of metastatic breast cancer. A radical left mastectomy with axillary dissection (1 of 43 nodes positive) followed by chemotherapy, was performed in 1998. She represented in October 2003 with a left supraclavicular fossa mass. This was confirmed to be recurrent breast cancer on FNAB. She was considered for a radical neck dissection and the surgeon requested a PET scan. Other imaging at this time included a normal bone scan and CT brain. CT neck/chest/abdomen/pelvis showed soft tissue thickening in the left lower neck. The PET-CT scan showed multiple glucose avid lesions in the sternum, mediastinum and neck lymph nodes as well as a small lesion in the proximal left femur consistent with extensive metastatic disease. Surgery was cancelled and Femara chemotherapy commenced. Femara was stopped in March 2004 and the patient began alternative therapies. In October 2004 she presented to her surgeon with new back and chest pain. CT of the neck/chest/abdomen/pelvis showed a soft tissue mass in the upper sternum and a lymph node at the base of the neck highly suspicious for metastatic disease. There were also 2 suspicious lung nodules and a lesion in the proximal left femur reported as an osteoid osteoma. Wholebody PET-CT scans were performed on a Siemens LSO Biograph, 60mins after the injection of 350Mbq of Fl 8-Fag, with arms at the patient's side and head in the field-of-view. On both occasions the patient had to pay for the scan. On the 2004 PET-CT scan, the CT brain revealed multiple hyperdense lesions consistent with hemorrhagic metastases. In addition, there were innumerable glucose avid foci involving viscera, nodes and skeleton consistent with disseminated disease. Our case illustrates: (i) the value of PET in the management of metastatic breast cancer; (ii) the improved accuracy of PET-CT in delineating sites of disease; (iii) the issues of head movement in PET-CT and. (iv) the problem with lack of

  3. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas

    Directory of Open Access Journals (Sweden)

    Almir Galvão Vieira Bitencourt

    2014-04-01

    Full Text Available Objective To correlate the results of 18F-fluoro-2-deoxy-D-glucose (18F-FDG positron emission tomography/computed tomography (PET/CT performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and Methods Cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results The authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm. Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%. At PET/CT, 53 (89.8% of the lesions demonstrated anomalous concentrations of 18F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5. A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas.

  4. Clinical evaluation of 2D versus 3D whole-body PET image quality using a dedicated BGO PET scanner

    International Nuclear Information System (INIS)

    Visvikis, D.; Griffiths, D.; Costa, D.C.; Bomanji, J.; Ell, P.J.

    2005-01-01

    Three-dimensional positron emission tomography (3D PET) results in higher system sensitivity, with an associated increase in the detection of scatter and random coincidences. The objective of this work was to compare, from a clinical perspective, 3D and two-dimensional (2D) acquisitions in terms of whole-body (WB) PET image quality with a dedicated BGO PET system. 2D and 3D WB emission acquisitions were carried out in 70 patients. Variable acquisition parameters in terms of time of emission acquisition per axial field of view (aFOV) and slice overlap between sequential aFOVs were used during the 3D acquisitions. 3D and 2D images were reconstructed using FORE+WLS and OSEM respectively. Scatter correction was performed by convolution subtraction and a model-based scatter correction in 2D and 3D respectively. All WB images were attenuation corrected using segmented transmission scans. Images were blindly assessed by three observers for the presence of artefacts, confidence in lesion detection and overall image quality using a scoring system. Statistically significant differences between 2D and 3D image quality were only obtained for 3D emission acquisitions of 3 min. No statistically significant differences were observed for image artefacts or lesion detectability scores. Image quality correlated significantly with patient weight for both modes of operation. Finally, no differences were seen in image artefact scores for the different axial slice overlaps considered, suggesting the use of five slice overlaps in 3D WB acquisitions. 3D WB imaging using a dedicated BGO-based PET scanner offers similar image quality to that obtained in 2D considering similar overall times of acquisitions. (orig.)

  5. Evaluation of a video-based head motion tracking system for dedicated brain PET

    Science.gov (United States)

    Anishchenko, S.; Beylin, D.; Stepanov, P.; Stepanov, A.; Weinberg, I. N.; Schaeffer, S.; Zavarzin, V.; Shaposhnikov, D.; Smith, M. F.

    2015-03-01

    Unintentional head motion during Positron Emission Tomography (PET) data acquisition can degrade PET image quality and lead to artifacts. Poor patient compliance, head tremor, and coughing are examples of movement sources. Head motion due to patient non-compliance can be an issue with the rise of amyloid brain PET in dementia patients. To preserve PET image resolution and quantitative accuracy, head motion can be tracked and corrected in the image reconstruction algorithm. While fiducial markers can be used, a contactless approach is preferable. A video-based head motion tracking system for a dedicated portable brain PET scanner was developed. Four wide-angle cameras organized in two stereo pairs are used for capturing video of the patient's head during the PET data acquisition. Facial points are automatically tracked and used to determine the six degree of freedom head pose as a function of time. The presented work evaluated the newly designed tracking system using a head phantom and a moving American College of Radiology (ACR) phantom. The mean video-tracking error was 0.99±0.90 mm relative to the magnetic tracking device used as ground truth. Qualitative evaluation with the ACR phantom shows the advantage of the motion tracking application. The developed system is able to perform tracking with accuracy close to millimeter and can help to preserve resolution of brain PET images in presence of movements.

  6. Positron Emission Tomography (PET) and breast cancer in clinical practice

    International Nuclear Information System (INIS)

    Lavayssiere, Robert; Cabee, Anne-Elizabeth; Filmont, Jean-Emmanuel

    2009-01-01

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005

  7. Positron Emission Tomography (PET) and breast cancer in clinical practice

    Energy Technology Data Exchange (ETDEWEB)

    Lavayssiere, Robert [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France)], E-mail: cab.lav@wanadoo.fr; Cabee, Anne-Elizabeth [Centre d' Imagerie Paris-Nord, 1, avenue Charles Peguy, 95200 Sarcelles (France); Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); Centre RMX, 80, avenue Felix Faure, 75105 Paris (France); Filmont, Jean-Emmanuel [Institut du Sein Henri Hartmann (ISHH), 1, rue des Dames Augustines, 92200 Neuilly sur Seine (France); American Hospital of Paris, Nuclear Medicine, 63, boulevard Victor Hugo - BP 109, 92202 Neuilly sur Seine Cedex (France)

    2009-01-15

    The landscape of oncologic practice has changed deeply during the past few years and there is now a need, through a multidisciplinary approach, for imaging to provide accurate evaluation of morphology and function and to guide treatment (Image Guided Therapy). Increasing emphasis has been put on Position Emission Tomography (PET) role in various cancers among clinicians and patients despite a general context of healthcare expenditure limitation. Positron Emission Tomography has currently a limited role in breast cancer, but also general radiologists and specialists should be aware of these indications, especially when staging aggressive cancers and looking for recurrence. Currently, the hybrid systems associating PET and Computed Tomography (CT) and in the same device [Rohren EM, Turkington TG, Coleman RE. Clinical applications of PET in oncology. Radiology 2004;231:305-32; Blodgett TM, Meltzer CM, Townsend DW. PET/CT: form and function. Radiology 2007;242:360-85; von Schulthess GK, Steinert HC, Hany TF. Integrated PET/CT: current applications and futures directions. Radiology 2006;238(2):405-22], or PET-CT, are more commonly used and the two techniques are adding their potentialities. Other techniques, MRI in particular, may also compete with PET in some instance and as far as ionizing radiations dose limitation is considered, some breast cancers becoming some form of a chronic disease. Breast cancer is a very complex, non-uniform, disease and molecular imaging at large may contribute to a better knowledge and to new drugs development. Ongoing research, Positron Emission Mammography (PEM) and new tracers, are likely to bring improvements in patient care [Kelloff GJ, Hoffman JM, Johnson B, et al. Progress and promise of FDG-PET Imaging for cancer patient management and oncologic drug development. Clin Cancer Res 2005;1(April (8)): 2005].

  8. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters.

    Science.gov (United States)

    Mhlanga, Joyce C; Carrino, John A; Lodge, Martin; Wang, Hao; Wahl, Richard L

    2014-12-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with (18)F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological (18)F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p = 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted.

  9. Reducing radiation dose to the female breast during conventional and dedicated breast computed tomography

    Science.gov (United States)

    Rupcich, Franco John

    The purpose of this study was to quantify the effectiveness of techniques intended to reduce dose to the breast during CT coronary angiography (CTCA) scans with respect to task-based image quality, and to evaluate the effectiveness of optimal energy weighting in improving contrast-to-noise ratio (CNR), and thus the potential for reducing breast dose, during energy-resolved dedicated breast CT. A database quantifying organ dose for several radiosensitive organs irradiated during CTCA, including the breast, was generated using Monte Carlo simulations. This database facilitates estimation of organ-specific dose deposited during CTCA protocols using arbitrary x-ray spectra or tube-current modulation schemes without the need to run Monte Carlo simulations. The database was used to estimate breast dose for simulated CT images acquired for a reference protocol and five protocols intended to reduce breast dose. For each protocol, the performance of two tasks (detection of signals with unknown locations) was compared over a range of breast dose levels using a task-based, signal-detectability metric: the estimator of the area under the exponential free-response relative operating characteristic curve, AFE. For large-diameter/medium-contrast signals, when maintaining equivalent AFE, the 80 kV partial, 80 kV, 120 kV partial, and 120 kV tube-current modulated protocols reduced breast dose by 85%, 81%, 18%, and 6%, respectively, while the shielded protocol increased breast dose by 68%. Results for the small-diameter/high-contrast signal followed similar trends, but with smaller magnitude of the percent changes in dose. The 80 kV protocols demonstrated the greatest reduction to breast dose, however, the subsequent increase in noise may be clinically unacceptable. Tube output for these protocols can be adjusted to achieve more desirable noise levels with lesser dose reduction. The improvement in CNR of optimally projection-based and image-based weighted images relative to photon

  10. PET-CT detection rate of primary breast cancer lesions. Correlation with the clinicopathological factors

    International Nuclear Information System (INIS)

    Ogawa, Tomoko; Tozaki, Mitsuhiro; Fukuma, Eisuke

    2008-01-01

    One hundred and forty lesions of primary breast cancer underwent positron emission tomography (PET)-CT between June 2006 and May 2007. The PET-CT detection rate of primary breast cancer lesions was 72.1%. The detection rate was 52.1% for invasive cancer ≤20 mm, 92.8% for invasive breast cancers >20 mm, and these results were significant. In the present study, no significant relationship was observed between tumor types, however, invasive lobular carcinoma showed a lower detection rate, 58.3%. The PET-CT results were not significantly affected by either estrogen and progesterone receptors or distant metastasis. A significant correlation regarding the detection rate of PET-CT was found with HER2 status, tumor grade, and axillary lymph node status. The detection rate was 100% for invasive cancer ≤20 mm when the interval between prior diagnostic Mammotome biopsies and PET-CT was less than 3 weeks, 18.8% for invasive cancer ≤20 mm when the interval was more than 3 weeks, and these results were significant. Mammotome biopsies may therefore affect the detection rate of PET-CT. Invasive cancers ≤20 mm showed a low detection rate, therefore, it is considered to be insufficient to use PET-CT for the detection of early breast cancer. (author)

  11. Initial experience with FDG-PET/CT in the evaluation of breast cancer

    International Nuclear Information System (INIS)

    Tatsumi, Mitsuaki; Cohade, Christian; Mourtzikos, Karen A.; Wahl, Richard L.; Fishman, Elliot K.

    2006-01-01

    We retrospectively reviewed FDG-PET/CT images in patients with breast cancer to determine whether PET/CT improved the level of diagnostic confidence as compared with PET and to compare PET/CT and CT findings at the location of suspected malignancies. The study included 75 patients with known breast cancer. The initial PET/CT study for each patient was retrospectively reviewed to determine whether improved diagnostic confidence (IDC) regarding lesion localization and characterization was observed with PET/CT as compared with PET alone. PET/CT and CT findings were compared regarding lesion characterization and staging in 69 of the 75 patients, and in the case of discordant findings, comparison with histological or informative follow-up results was also performed. Fifty of the 75 patients exhibited increased FDG uptake in a total of 95 regions. In the comparison of PET/CT and PET, PET/CT resulted in IDC in 30 (60%) of these 50 patients and in 52 (55%) of the 95 regions. In the comparison between PET/CT and CT in 69 patients, PET/CT demonstrated a significantly better accuracy than CT (P<0.05). PET/CT showed definitely positive findings in 60 regions with malignancies, among which CT exhibited positive findings in 43 (72%). PET/CT and CT accurately staged 59 (86%) and 53 (77%) of the 69 patients, respectively. (orig.)

  12. Cone-beam micro computed tomography dedicated to the breast.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Di Lillo, Francesca; Cesarelli, Mario; Bifulco, Paolo; Russo, Paolo

    2016-12-01

    We developed a scanner for micro computed tomography dedicated to the breast (BµCT) with a high resolution flat-panel detector and a microfocus X-ray tube. We evaluated the system spatial resolution via the 3D modulation transfer function (MTF). In addition to conventional absorption-based X-ray imaging, such a prototype showed capabilities for propagation-based phase-contrast and related edge enhancement effects in 3D imaging. The system limiting spatial resolution is 6.2mm -1 (MTF at 10%) in the vertical direction and 3.8mm -1 in the radial direction, values which compare favorably with the spatial resolution reached by mini focus breast CT scanners of other groups. The BµCT scanner was able to detect both microcalcification clusters and masses in an anthropomorphic breast phantom at a dose comparable to that of two-view mammography. The use of a breast holder is proposed in order to have 1-2min long scan times without breast motion artifacts. Copyright © 2016 IPEM. Published by Elsevier Ltd. All rights reserved.

  13. PET and Hormone Receptor Ligands in Breast Cancer

    National Research Council Canada - National Science Library

    Gemignani, Mary

    2006-01-01

    .... To investigate this further, this project's objectives are: To evaluate the use of estrogen-like ligands labeled with positron emitters in preoperatively determining the ER status of breast cancer using PET...

  14. Clinical and diagnostic value of preoperative MR mammography and FDG-PET in suspicious breast lesions

    International Nuclear Information System (INIS)

    Walter, C.; Scheidhauer, K.; Theissen, P.; Scharl, A.; Goering, U.J.; Kugel, H.; Krahe, T.; Pietrzyk, U.

    2003-01-01

    Dynamic enhanced magnetic resonance (MR) mammography and fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) of the breast were directly compared preoperatively in suspicious breast lesions. Forty-two breast lesions in 40 patients were examined with a three-dimensional dynamic MR imaging series and FDG-PET. The MR and PET examinations were evaluated separately and the results were compared with the histological findings. The sensitivity and specificity of each method were calculated. The diagnostic value of both modalities as single diagnostic tool and in combination was investigated. Nineteen malignant and 23 benign breast lesions were proven histologically. Magnetic resonance mammography and FDG-PET showed a sensitivity of 89 and 63%, respectively. The specificity was 74 and 91%, respectively. The combination of both imaging methods decreased the not-required biopsies from 55 to 17%. Only one false-negative finding - a patient pre-treated with chemotherapy - was observed in both methods. The combination of MR mammography and FDG-PET can help to decrease biopsies of benign breast lesions. Because of their high cost, these modalities should only be used in problematic cases to either rule out or to demonstrate malignancy. The best diagnostic strategy is achieved using MR mammography first. If the diagnosis is still questionable, FDG-PET can be performed. (orig.)

  15. 18F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    International Nuclear Information System (INIS)

    Mhlanga, Joyce C.; Lodge, Martin; Carrino, John A.; Wang, Hao; Wahl, Richard L.

    2014-01-01

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with 18 F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological 18 F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  16. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5 pts (range: 12-32% increase in max D and 12-39% increase in SUV) and RT-CT detected PD in 3 pts (11-21% increase in max D, paired t test: p = 0.19). Stage-PET detected 28 mediastinal/hilar nodal sites. RT-PET detected PD in 11 of these lesions in 4 pts (31%) and CT detected similar progression in 8 lesions in 2 pts. RT-PET detected 10 new lesions in 3 pts (23%) resulting in upstaging to N3 in 2 pts (supraclavicular and hilar nodes) and M1 in 1 pt (bone). Conclusion: A dedicated RT PET-CT has the potential to detect disease progression and impact on RT planning in a large number of patients.

  17. Clear-PEM, a dedicated PET camera for mammography

    CERN Document Server

    Lecoq, P

    2002-01-01

    Preliminary results suggest that Positron Emission Mammography (PEM) can offer a noninvasive method for the diagnosis of breast cancer. Metabolic images from PEM contain unique information not available from conventional morphologic imaging techniques and aid in expeditiously establishing the diagnosis of cancer. A dedicated machine seems to offer better perspectives in terms of position resolution and sensitivity. This paper describes the concept of Clear-PEM, the system presently developed by the Crystal Clear Collaboration at CERN for an evaluation of this approach. This device is based on new crystals introduced by the Crystal Clear as well as on modern data acquisition techniques developed for the large experiments in high energy physics experiments.

  18. Dedicated mobile high resolution prostate PET imager with an insertable transrectal probe

    Science.gov (United States)

    Majewski, Stanislaw; Proffitt, James

    2010-12-28

    A dedicated mobile PET imaging system to image the prostate and surrounding organs. The imaging system includes an outside high resolution PET imager placed close to the patient's torso and an insertable and compact transrectal probe that is placed in close proximity to the prostate and operates in conjunction with the outside imager. The two detector systems are spatially co-registered to each other. The outside imager is mounted on an open rotating gantry to provide torso-wide 3D images of the prostate and surrounding tissue and organs. The insertable probe provides closer imaging, high sensitivity, and very high resolution predominately 2D view of the prostate and immediate surroundings. The probe is operated in conjunction with the outside imager and a fast data acquisition system to provide very high resolution reconstruction of the prostate and surrounding tissue and organs.

  19. MR-Guided High-Intensity Focused Ultrasound Ablation of Breast Cancer with a Dedicated Breast Platform

    International Nuclear Information System (INIS)

    Merckel, Laura G.; Bartels, Lambertus W.; Köhler, Max O.; Bongard, H. J. G. Desirée van den; Deckers, Roel; Mali, Willem P. Th. M.; Binkert, Christoph A.; Moonen, Chrit T.; Gilhuijs, Kenneth G. A.; Bosch, Maurice A. A. J. van den

    2013-01-01

    Optimizing the treatment of breast cancer remains a major topic of interest. In current clinical practice, breast-conserving therapy is the standard of care for patients with localized breast cancer. Technological developments have fueled interest in less invasive breast cancer treatment. Magnetic resonance-guided high-intensity focused ultrasound (MR-HIFU) is a completely noninvasive ablation technique. Focused beams of ultrasound are used for ablation of the target lesion without disrupting the skin and subcutaneous tissues in the beam path. MRI is an excellent imaging method for tumor targeting, treatment monitoring, and evaluation of treatment results. The combination of HIFU and MR imaging offers an opportunity for image-guided ablation of breast cancer. Previous studies of MR-HIFU in breast cancer patients reported a limited efficacy, which hampered the clinical translation of this technique. These prior studies were performed without an MR-HIFU system specifically developed for breast cancer treatment. In this article, a novel and dedicated MR-HIFU breast platform is presented. This system has been designed for safe and effective MR-HIFU ablation of breast cancer. Furthermore, both clinical and technical challenges are discussed, which have to be solved before MR-HIFU ablation of breast cancer can be implemented in routine clinical practice.

  20. Usefulness of 18F fluoride PET/CT in breast cancer patients with osteosclerotic bone metastases

    International Nuclear Information System (INIS)

    Yoon, Seok Ho; Kim, Ku Sang; Kang, Seok Yun; Song, Hee Sung; Jo, Kyung Sook; Lee, Su Jin; Yoon, Joon Kee; An, Young Sil; Choi, Bong Hoi

    2012-01-01

    Bone metastasis is an important factor for the treatment and prognosis of breast cancer patients. Whole body bone scintigraphy (WBBS) can evaluate skeletal metastases, and 18 F FDG PET/CT seems to exhibit high specificity and accuracy in detecting bone metastases. However, there is a limitation of 18 F FDG PET in assessing sclerotic bone metastases because some lesions may be undetectable. Recent studies showed that 18 F fluoride PET/CT is more sensitive than WBBS in detecting bone metastases. This study aims to evaluate the usefulness of 18 F fluoride PET/CT by comparing it with WBBS and 18 F FDG PET/CT in breast cancer patients with osteosclerotic skeletal metastases. Nine breast cancer patients with suspected bone metastases (9 females; mean age ± SD, 55.6±10.0 years) underwent 99m Tc MDP WBBS, 18 F FDG PET/CT and 18 F fluoride PET/CT. Lesion based analysis of five regions of the skeletons(skull, vertebral column, thoracic cage, pelvic bones and long bones of extremities) and patient based analysis were performed. 18 F fluoride PET/CT, 18 F FDG PET/CT and WBBS detected 49, 20 and 25 true metastases, respectively. Sensitivity, specificity, positive predictive value and negative predictive value of 18 F fluoride PET/CT were 94.2%, 46.3%, 57.7% and 91.2%, respectively. Most true metastatic lesions of 18 F fluoride PET/CT had osteosclerotic change (45/49, 91.8%), and only four lesions showed osteolytic change. Most lesions on 18 F FDG PET/CT also demonstrated osteosclerotic change (17/20, 85.0%) with three osteolytic lesions. All true metastatic lesions detected on WBBS and 18 F FDG PET/CT were identified on 18 F fluoride PET/CT. 18 F FDG PET/CT in detecting osteosclerotic metastatic lesions. 18 F fluoride PET/CT might be useful in evaluating osteosclerotic metastases in breast cancer patients

  1. Dedicated breast CT: radiation dose for circle-plus-line trajectory

    International Nuclear Information System (INIS)

    Vedantham, Srinivasan; Shi, Linxi; Karellas, Andrew; Noo, Frederic

    2012-01-01

    Purpose: Dedicated breast CT prototypes used in clinical investigations utilize single circular source trajectory and cone-beam geometry with flat-panel detectors that do not satisfy data-sufficiency conditions and could lead to cone beam artifacts. Hence, this work investigated the glandular dose characteristics of a circle-plus-line trajectory that fulfills data-sufficiency conditions for image reconstruction in dedicated breast CT. Methods: Monte Carlo-based computer simulations were performed using the GEANT4 toolkit and was validated with previously reported normalized glandular dose coefficients for one prototype breast CT system. Upon validation, Monte Carlo simulations were performed to determine the normalized glandular dose coefficients as a function of x-ray source position along the line scan. The source-to-axis of rotation distance and the source-to-detector distance were maintained constant at 65 and 100 cm, respectively, in all simulations. The ratio of the normalized glandular dose coefficient at each source position along the line scan to that for the circular scan, defined as relative normalized glandular dose coefficient (RD g N), was studied by varying the diameter of the breast at the chest wall, chest-wall to nipple distance, skin thickness, x-ray beam energy, and glandular fraction of the breast. Results: The RD g N metric when stated as a function of source position along the line scan, relative to the maximum length of line scan needed for data sufficiency, was found to be minimally dependent on breast diameter, chest-wall to nipple distance, skin thickness, glandular fraction, and x-ray photon energy. This observation facilitates easy estimation of the average glandular dose of the line scan. Polynomial fit equations for computing the RD g N and hence the average glandular dose are provided. Conclusions: For a breast CT system that acquires 300-500 projections over 2π for the circular scan, the addition of a line trajectory with equal

  2. {sup 18}F-FDG PET of the hands with a dedicated high-resolution PEM system (arthro-PET): correlation with PET/CT, radiography and clinical parameters

    Energy Technology Data Exchange (ETDEWEB)

    Mhlanga, Joyce C.; Lodge, Martin [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Carrino, John A. [Johns Hopkins University School of Medicine, Division of Musculoskeletal Radiology, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Wang, Hao [Johns Hopkins University School of Medicine, Department of Oncology Biostatistics Division, Baltimore, MD (United States); Wahl, Richard L. [Johns Hopkins University School of Medicine, Division of Nuclear Medicine, The Russell H. Morgan Department of Radiology and Radiological Sciences, Baltimore, MD (United States); Johns Hopkins University Hospitals, Division of Nuclear Medicine, Baltimore, MD (United States)

    2014-12-15

    The aim of this study was to prospectively determine the feasibility and compare the novel use of a positron emission mammography (PEM) scanner with standard PET/CT for evaluating hand osteoarthritis (OA) with {sup 18}F-FDG. Institutional review board approval and written informed consent were obtained for this HIPAA-compliant prospective study in which 14 adults referred for oncological {sup 18}F-FDG PET/CT underwent dedicated hand PET/CT followed by arthro-PET using the PEM device. Hand radiographs were obtained and scored for the presence and severity of OA. Summed qualitative and quantitative joint glycolytic scores for each modality were compared with the findings on plain radiography and clinical features. Eight patients with clinical and/or radiographic evidence of OA comprised the OA group (mean age 73 ± 7.7 years). Six patients served as the control group (53.7 ± 9.3 years). Arthro-PET quantitative and qualitative joint glycolytic scores were highly correlated with PET/CT findings in the OA patients (r = 0.86. p = 0.007; r = 0.94, p = 0.001). Qualitative arthro-PET and PET/CT joint scores were significantly higher in the OA patients than in controls (38.7 ± 6.6 vs. 32.2 ± 0.4, p = 0.02; 37.5 ± 5.4 vs. 32.2 ± 0.4, p = 0.03, respectively). Quantitative arthro-PET and PET/CT maximum SUV-lean joint scores were higher in the OA patients, although they did not reach statistical significance (20.8 ± 4.2 vs. 18 ± 1.8, p = 0.13; 22.8 ± 5.38 vs. 20.1 ± 1.54, p= 0.21). By definition, OA patients had higher radiographic joint scores than controls (30.9 ± 31.3 vs. 0, p = 0.03). Hand imaging using a small field of view PEM system (arthro-PET) with FDG is feasible, performing comparably to PET/CT in assessing metabolic joint activity. Arthro-PET and PET/CT showed higher joint FDG uptake in OA. Further exploration of arthro-PET in arthritis management is warranted. (orig.)

  3. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    OpenAIRE

    Dang, J; Lecoq, P; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    International audience; Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allo...

  4. Study and development of a PET device dedicated to cancer monitoring

    International Nuclear Information System (INIS)

    Vandenbussche, Vincent

    2014-01-01

    Medical imaging first began at the end of the 19. century with the discover of X-rays by Roentgen. Then, numerous imaging modalities have been developed and are used now for a wide range of cases. Positron Emission Tomography (PET) has a high sensitivity, is functional and quantitative, thus being of high interest in cancer monitoring. Nevertheless, PET is not as much spread in hospitals as magnetic resonance imaging and scanner. In this context, this work aims to prove the feasibility of PET dedicated for cancer monitoring. Thanks to instrumental developments such as light sharing in scintillating crystals, use of Silicon Photomultipliers, and an original geometry, cost is expected to be reduced while having same performances as commercial devices. An extensive study of light sharing within scintillating barrels has been made, through many parameters (crystal length, coating, data analysis...). An intrinsic spatial resolution of 4 mm has been measured over a 75 mm long crystal of LYSO, coated with teflon. From such a configuration, a first image has been reconstructed using two modules in coincidence. A spatial resolution of 5 mm has been measured in the image. Finally, Monte Carlo simulations has been made with experimental data as input, in order to measure the performances of the final PET device. Thanks to NEMA standard protocol, performances has been measured and compared to other systems. A spatial resolution of 4 mm has been reached, for a sensitivity of 2.5 cps/kBq. Quantification problem has been assessed, providing results similar to existing devices. (author) [fr

  5. Diagnostic evaluation of the breast using PET: optimization of data acquisition and postprocessing

    International Nuclear Information System (INIS)

    Brix, G.; Lucht, R.; Henze, M.; Doll, J.; Zaers, J.; Trojan, H.; Knopp, M.V.; Haberkorn, U.; Deutsches Krebsforschungszentrum, Heidelberg

    2000-01-01

    Purpose: Development and evaluation of an optimized protocol for PET examinations of the female breast with 2-F-18-fluoro-2-deoxyglucose (F-18-FDG). Methods: All PET measurements were performed with a whole-body PET system (ECAT EXACT HR + ). In order to examine the women with the breasts freely pendant, a special extension for the patient table made of carbon layer composite was designed. After data acquisition in the 3D modus, emission data were sorted into 2D sinograms using the Fourier rebinning algorithm and reconstructed by means of an ultra-fast iterative 2D algorithm (HOSP). The reconstructed emission scans were superimposed onto the corresponding transmission images. The protocol presented was evaluated in examinations on 6 women with breast lesions after the administration of 150-220 MBq F-18-FDG. From two adjacent bed positions, emission and transmission data were acquired over periods of 20 min and 10 min, respectively. For comparison, dynamic magnetic resonance (MR) image series were acquired with a whole-body MR system (MAGNETOM SP 4000) using a double-breast coil. Results and Conclusion: Using the designed extension of the patient table, it was possible to examine corpulent women despite the limited patient part of the PET system in the prone position with the breasts freely pendant. Alongside a reduction in motion artifacts, this positioning also offers the possibility of making a direct comparison between PET and MR images. Despite the fact that the amount of F-18-FDG applied to the patient was markedly reduced, the combination of 3D data acquisition and iterative image reconstruction resulted in excellent quality of the emission scans. By superpositioning of iteratively reconstructed emission and transmission scans, anatomical localization of breast lesions visualized on the emission scans could be improved. The postprocessing of the PET data described was completed in 60 min, this meaning that the presented concept can readily be employed in

  6. WE-FG-207A-00: Advances in Dedicated Breast CT

    International Nuclear Information System (INIS)

    2016-01-01

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  7. WE-FG-207A-00: Advances in Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2016-06-15

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  8. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    International Nuclear Information System (INIS)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-01-01

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  9. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Grueneisen, Johannes, E-mail: Johannes.grueneisen@uk-essen.de [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Sawicki, Lino Morris [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Wetter, Axel [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Kirchner, Julian [Department of Diagnostic and Interventional Radiology, University Hospital, Dusseldorf, University of Dusseldorf, D-40225 Dusseldorf (Germany); Kinner, Sonja [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Aktas, Bahriye [Department of Obstetrics and Gynecology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Ruhlmann, Verena [Department of Nuclear Medicine, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany); Umutlu, Lale [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University of Duisburg-Essen, D-45147 Essen (Germany)

    2017-04-15

    Objectives: To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. Methods: A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Results: Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (p < 0.05). Furthermore, all three PET/MR sequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p > 0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2 w HASTE and diffusion-weighted imaging. Conclusion: Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer

  10. TU-EF-207-05: Dedicated Cone-beam Breast CT

    International Nuclear Information System (INIS)

    Vedantham, S.

    2015-01-01

    mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation

  11. TU-EF-207-05: Dedicated Cone-beam Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, S. [Univ. of Massachusetts Medical School (United States)

    2015-06-15

    mode due to lower photon fluence per projection. This may require fast-frame acquisition and symmetric or asymmetric pixel binning in some systems. Recent studies investigated the performance of increased conversion layer thickness for contrast-enhanced imaging of the breast in dual-energy acquisition mode. In other direct conversion detectors operating in the avalanche mode, sensitivities close to the single photon response are also explored for mammography and breast tomosynthesis. The potential advantages and challenges of this approach are described. Dedicated breast CT brings x-ray imaging of the breast to true tomographic 3D imaging. It can eliminate the tissue superposition problem and does not require physical compression of the breast. Using cone beam geometry and a flat-panel detector, several hundred projections are acquired and reconstructed to near isotropic voxels. Multiplanar reconstruction facilitates viewing the breast volume in any desired orientation. Ongoing clinical studies, the current state-of-the art, and research to advance the technology are described. Learning Objectives: To understand the ongoing developments in x-ray imaging of the breast To understand the approaches and applications of spectral mammography To understand the potential advantages of distributed x-ray source arrays for digital breast tomosynthesis To understand the ongoing developments in detector technology for digital mammography and breast tomosynthesis To understand the current state-of-the-art for dedicated cone-beam breast CT and research to advance the technology. Research collaboration with Koning Corporation.

  12. Evaluation of PET and MR datasets in integrated 18F-FDG PET/MRI: A comparison of different MR sequences for whole-body restaging of breast cancer patients.

    Science.gov (United States)

    Grueneisen, Johannes; Sawicki, Lino Morris; Wetter, Axel; Kirchner, Julian; Kinner, Sonja; Aktas, Bahriye; Forsting, Michael; Ruhlmann, Verena; Umutlu, Lale

    2017-04-01

    To investigate the diagnostic value of different MR sequences and 18F-FDG PET data for whole-body restaging of breast cancer patients utilizing PET/MRI. A total of 36 patients with suspected tumor recurrence of breast cancer based on clinical follow-up or abnormal findings in follow-up examinations (e.g. CT, MRI) were prospectively enrolled in this study. All patients underwent a PET/CT and subsequently an additional PET/MR scan. Two readers were instructed to identify the occurrence of a tumor relapse in subsequent MR and PET/MR readings, utilizing different MR sequence constellations for each session. The diagnostic confidence for the determination of a malignant or benign lesion was qualitatively rated (3-point ordinal scale) for each lesion in the different reading sessions and the lesion conspicuity (4-point ordinal scale) for the three different MR sequences was additionally evaluated. Tumor recurrence was present in 25/36 (69%) patients. All three PET/MRI readings showed a significantly higher accuracy as well as higher confidence levels for the detection of recurrent breast cancer lesions when compared to MRI alone (psequence constellations showed comparable diagnostic accuracy for the identification of a breast cancer recurrence (p>0.05), yet the highest confidence levels were obtained, when all three MR sequences were used for image interpretation. Moreover, contrast-enhanced T1-weighted VIBE imaging showed significantly higher values for the delineation of malignant and benign lesions when compared to T2w HASTE and diffusion-weighted imaging. Integrated PET/MRI provides superior restaging of breast cancer patients over MRI alone. Facing the need for appropriate and efficient whole-body PET/MR protocols, our results show the feasibility of fast and morphologically adequate PET/MR protocols. However, considering an equivalent accuracy for the detection of breast cancer recurrences in the three PET/MR readings, the application of contrast-agent and the

  13. {sup 68}Ga-PSMA-HBED-CC PET imaging in breast carcinoma patients

    Energy Technology Data Exchange (ETDEWEB)

    Sathekge, Mike; Lengana, Thabo; Modiselle, Moshe; Vorster, Mariza; Zeevaart, JanRijn; Ebenhan, Thomas [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); Maes, Alex [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); AZ Groeninge, Department of Nuclear Medicine, Kortrijk (Belgium); Wiele, Christophe van de [University of Pretoria and Steve Biko Academic Hospital, Department of Nuclear Medicine, Pretoria (South Africa); University Ghent, Department of Radiology and Nuclear Medicine, Ghent (Belgium)

    2017-04-15

    To report on imaging findings using {sup 68}Ga-PSMA-HBED-CC PET in a series of 19 breast carcinoma patients. {sup 68}Ga-PSMA-HBED-CC PET imaging results obtained were compared to routinely performed staging examinations and analyzed as to lesion location and progesterone receptor status. Out of 81 tumor lesions identified, 84% were identified on {sup 68}Ga-PSMA-HBED-CC PET. {sup 68}Ga-PSMA-HBED-CC SUVmean values of distant metastases proved significantly higher (mean, 6.86, SD, 5.68) when compared to those of primary or local recurrences (mean, 2.45, SD, 2.55, p = 0.04) or involved lymph nodes (mean, 3.18, SD, 1.79, p = 0.011). SUVmean values of progesterone receptor-positive lesions proved not significantly different from progesterone receptor-negative lesions. SUV values derived from FDG PET/CT, available in seven patients, and {sup 68}Ga-PSMA-HBED-CC PET/CT imaging proved weakly correlated (r = 0.407, p = 0.015). {sup 68}Ga-PSMA-HBED-CC PET/CT imaging in breast carcinoma confirms the reported considerable variation of PSMA expression on human solid tumors using immunohistochemistry. (orig.)

  14. Comparison of CE-FDG-PET/CT with CE-FDG-PET/MR in the evaluation of osseous metastases in breast cancer patients

    OpenAIRE

    Catalano, O A; Nicolai, E; Rosen, B R; Luongo, A; Catalano, M; Iannace, C; Guimaraes, A; Vangel, M G; Mahmood, U; Soricelli, A; Salvatore, M

    2015-01-01

    Background: Despite improvements in treatments, metastatic breast cancer remains difficult to cure. Bones constitute the most common site of first-time recurrence, occurring in 40?75% of cases. Therefore, evaluation for possible osseous metastases is crucial. Technetium 99 (99Tc) bone scintigraphy and fluorodexossyglucose (FDG) positron emission tomography (PET)-computed tomography (PET-CT) are the most commonly used techniques to assess osseous metastasis. PET magnetic resonance (PET-MR) ima...

  15. Correlation between PET/CT results and histological and immunohistochemical findings in breast carcinomas; Correlacao entre resultado do PET/CT e achados histologicos e imuno-histoquimicos em carcinomas mamarios

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Lima, Eduardo Nobrega Pereira; Chojniak, Rubens; Marques, Elvira Ferreira; Souza, Juliana Alves de; Graziano, Luciana; Andrade, Wesley Pereira; Osorio, Cynthia Aparecida Bueno de Toledo, E-mail: almirgvb@yahoo.com.br [A.C.Camargo Cancer Center, Sao Paulo, SP (Brazil)

    2014-03-15

    Objective: to correlate the results of {sup 18}F-fluoro-2-deoxy-D-glucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) performed with a specific protocol for assessment of breasts with histological/immunohistochemical findings in breast carcinoma patients. Materials and methods: cross-sectional study with prospective data collection, where patients with biopsy-confirmed breast carcinomas were studied. The patients underwent PET/CT examination in prone position, with a specific protocol for assessment of breasts. PET/CT findings were compared with histological and immunohistochemical data. Results: the authors identified 59 malignant breast lesions in 50 patients. The maximum diameter of the lesions ranged from 6 to 80 mm (mean: 32.2 mm). Invasive ductal carcinoma was the most common histological type (n = 47; 79.7%). At PET/CT, 53 (89.8%) of the lesions demonstrated anomalous concentrations of {sup 18}F-FDG, with maximum SUV ranging from 0.8 to 23.1 (mean: 5.5). A statistically significant association was observed between higher values of maximum SUV and histological type, histological grade, molecular subtype, tumor diameter, mitotic index and Ki-67 expression. Conclusion: PET/CT performed with specific protocol for assessment of breasts has demonstrated good sensitivity and was associated with relevant histological/immunohistochemical factors related to aggressiveness and prognosis of breast carcinomas. (author)

  16. Multiparametric and molecular imaging of breast tumors with MRI and PET/MRI; Multiparametrische und molekulare Bildgebung von Brusttumoren mit MRT und PET-MRT

    Energy Technology Data Exchange (ETDEWEB)

    Pinker, K. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Memorial Sloan-Kettering Cancer Center, Department of Radiology, Molecular Imaging and Therapy Service, New York (United States); State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Marino, M.A. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria); Policlinico Universitario G. Martino, University of Messina, Department of Biomedical Sciences and Morphologic and Functional Imaging, Messina (Italy); Meyer-Baese, A. [State University of Florida, Department of Scientific Computing in Medicine, Florida (United States); Helbich, T.H. [Medizinische Universitaet Wien, Universitaetsklinik fuer Radiologie und Nuklearmedizin, Division fuer Molekulare und Gender Bildgebung, Wien (Austria)

    2016-07-15

    Magnetic resonance imaging (MRI) of the breast is an indispensable tool in breast imaging for many indications. Several functional parameters with MRI and positron emission tomography (PET) have been assessed for imaging of breast tumors and their combined application is defined as multiparametric imaging. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the hallmarks of cancer and may provide additional specificity. Multiparametric and molecular imaging of the breast comprises established MRI parameters, such as dynamic contrast-enhanced MRI, diffusion-weighted imaging (DWI), MR proton spectroscopy ({sup 1}H-MRSI) as well as combinations of radiological and MRI techniques (e.g. PET/CT and PET/MRI) using radiotracers, such as fluorodeoxyglucose (FDG). Multiparametric and molecular imaging of the breast can be performed at different field-strengths (range 1.5-7 T). Emerging parameters comprise novel promising techniques, such as sodium imaging ({sup 23}Na MRI), phosphorus spectroscopy ({sup 31}P-MRSI), chemical exchange saturation transfer (CEST) imaging, blood oxygen level-dependent (BOLD) and hyperpolarized MRI as well as various specific radiotracers. Multiparametric and molecular imaging has multiple applications in breast imaging. Multiparametric and molecular imaging of the breast is an evolving field that will enable improved detection, characterization, staging and monitoring for personalized medicine in breast cancer. (orig.) [German] Die Magnetresonanztomographie (MRT) der Brust ist ein etabliertes nichtinvasives bildgebendes Verfahren mit vielfaeltigen Indikationen. In den letzten Jahren wurden zahlreiche funktionelle MRT- und Positronenemissionstomographie(PET)-Parameter in der Brustbildgebung evaluiert, und ihre kombinierte Anwendung ist als multiparametrische Bildgebung definiert. Bisherige Daten legen nahe, dass die multiparametrische Bildgebung mit MRT und PET

  17. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    International Nuclear Information System (INIS)

    Hernandez, A; Gazi, P; Seibert, J; Boone, J

    2015-01-01

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R 2 ) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R 2 values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image

  18. TU-CD-207-11: Patient-Driven Automatic Exposure Control for Dedicated Breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A; Gazi, P [Biomedical Engineering Graduate Group, University of California Davis, Davis, CA (United States); Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Seibert, J; Boone, J [Department of Radiology, UC Davis Medical Center, Sacramento, CA (United States); Department of Biomedical Engineering, University of California Davis, Davis, CA (United States)

    2015-06-15

    Purpose: To implement automatic exposure control (AEC) in dedicated breast CT (bCT) on a patient-specific basis using only the pre-scan scout views. Methods: Using a large cohort (N=153) of bCT data sets, the breast effective diameter (D) and width in orthogonal planes (Wa,Wb) were calculated from the reconstructed bCT image and pre-scan scout views, respectively. D, Wa, and Wb were measured at the breast center-of-mass (COM), making use of the known geometry of our bCT system. These data were then fit to a second-order polynomial “D=F(Wa,Wb)” in a least squares sense in order to provide a functional form for determining the breast diameter. The coefficient of determination (R{sup 2}) and mean percent error between the measured breast diameter and fit breast diameter were used to evaluate the overall robustness of the polynomial fit. Lastly, previously-reported bCT technique factors derived from Monte Carlo simulations were used to determine the tube current required for each breast diameter in order to match two-view mammographic dose levels. Results: F(Wa,Wb) provided fitted breast diameters in agreement with the measured breast diameters resulting in R{sup 2} values ranging from 0.908 to 0.929 and mean percent errors ranging from 3.2% to 3.7%. For all 153 bCT data sets used in this study, the fitted breast diameters ranged from 7.9 cm to 15.7 cm corresponding to tube current values ranging from 0.6 mA to 4.9 mA in order to deliver the same dose as two-view mammography in a 50% glandular breast with a 80 kV x-ray beam and 16.6 second scan time. Conclusion: The present work provides a robust framework for AEC in dedicated bCT using only the width measurements derived from the two orthogonal pre-scan scout views. Future work will investigate how these automatically chosen exposure levels affect the quality of the reconstructed image.

  19. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    CERN Document Server

    Dang, J; Tavernier, S; Lasaygues, P; Mensah, S; Zhang, D C; Auffray, E; Frisch, B; Varela, J; Wan, M X; Felix, N

    2011-01-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Soni...

  20. Sci—Thur AM: YIS - 08: Constructing an Attenuation map for a PET/MR Breast coil

    International Nuclear Information System (INIS)

    Patrick, John C.; So, Aaron; Butler, John; Faul, David; Yartsev, Slav; Thompson, Terry; Prato, Frank S.; Gaede, Stewart

    2014-01-01

    In 2013, around 23000 Canadian women and 200 Canadian men were diagnosed with breast cancer. An estimated 5100 women and 55 men died from the disease. Using the sensitivity of MRI with the selectivity of PET, PET/MRI combines anatomical and functional information within the same scan and could help with early detection in high-risk patients. MRI requires radiofrequency coils for transmitting energy and receiving signal but the breast coil attenuates PET signal. To correct for this PET attenuation, a 3-dimensional map of linear attenuation coefficients (μ-map) of the breast coil must be created and incorporated into the PET reconstruction process. Several approaches have been proposed for building hardware μ-maps, some of which include the use of conventional kVCT and Dual energy CT. These methods can produce high resolution images based on the electron densities of materials that can be converted into μ-maps. However, imaging hardware containing metal components with photons in the kV range is susceptible to metal artifacts. These artifacts can compromise the accuracy of the resulting μ-map and PET reconstruction; therefore high-Z components should be removed. We propose a method for calculating μ-maps without removing coil components, based on megavoltage (MV) imaging with a linear accelerator that has been detuned for imaging at 1.0MeV. Containers of known geometry with F18 were placed in the breast coil for imaging. A comparison between reconstructions based on the different μ-map construction methods was made. PET reconstructions with our method show a maximum of 6% difference over the existing kVCT-based reconstructions

  1. One-Step 18F-Labeling of Estradiol Derivative for PET Imaging of Breast Cancer

    Directory of Open Access Journals (Sweden)

    Hongbo Huang

    2018-01-01

    Full Text Available Positron emission tomography (PET imaging is a useful method to evaluate in situ estrogen receptor (ER status for the early diagnosis of breast cancer and optimization of the appropriate treatment strategy. The 18F-labeled estradiol derivative has been successfully used to clinically assess the ER level of breast cancer. In order to simplify the radiosynthesis process, one-step 18F-19F isotope exchange reaction was employed for the 18F-fluorination of the tracer of [18F]AmBF3-TEG-ES. The radiotracer was obtained with the radiochemical yield (RCY of ~61% and the radiochemical purity (RCP of >98% within 40 min. Cell uptake and blocking assays indicated that the tracer could selectively accumulate in the ER-positive human breast cancer cell lines MCF-7 and T47D. In vivo PET imaging on the MCF-7 tumor-bearing mice showed relatively high tumor uptake (1.4~2.3 %D/g and tumor/muscle uptake ratio (4~6. These results indicated that the tracer is a promising PET imaging agent for ER-positive breast cancers.

  2. High resolution PET breast imager with improved detection efficiency

    Science.gov (United States)

    Majewski, Stanislaw

    2010-06-08

    A highly efficient PET breast imager for detecting lesions in the entire breast including those located close to the patient's chest wall. The breast imager includes a ring of imaging modules surrounding the imaged breast. Each imaging module includes a slant imaging light guide inserted between a gamma radiation sensor and a photodetector. The slant light guide permits the gamma radiation sensors to be placed in close proximity to the skin of the chest wall thereby extending the sensitive region of the imager to the base of the breast. Several types of photodetectors are proposed for use in the detector modules, with compact silicon photomultipliers as the preferred choice, due to its high compactness. The geometry of the detector heads and the arrangement of the detector ring significantly reduce dead regions thereby improving detection efficiency for lesions located close to the chest wall.

  3. Prospective evaluation of fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) for axillary staging in breast cancer

    International Nuclear Information System (INIS)

    Yamaguchi, Masahide; Noguchi, Akinori; Tani, Naoki

    2008-01-01

    Seventy-two patients from 2005 October to 2007 February with operative breast cancer underwent fluorodeoxyglucose positron emission tomography/computed tomography scan (FDG-PET/CT) of chest and body, ultrasound scan (US) and enhanced computed tomography scan (CT) followed by sentinel lymph node biopsy (SLNB) and axillary lymph node dissection (ALND). The results of PET/CT were compared with histopathological diagnosis of SLNB and ALND. Sensitivity, specificity and accuracy of PET/CT for detection of axillary lymph node metastases were 61%, 96% and 88%, respectively. Seven false-negative and two false-positive of PET/CT results were found. In patients with false-negative of PET/CT results there are two skin-invasive breast cancer patients and axillary lymph node metastases were detected in three patients with US, in one with CT and in four with SLNB. In clinical method for diagnosis of axillary lymph node metastases SLNB should be recommended because sensitivity of PET/CT for early breast cancer patients were low and positive diagnosis of axillary lymph node metastases with PET needs more than 1 cm size of lesion. PET/CT is useful for not-early breast cancer patients. To decide the operation of axillary lymph node disection needs total diagnosis of US, CT, SLNB and clinical findings. (author)

  4. Breast cancer with low FDG uptake: Characterization by means of dual-time point FDG-PET/CT

    International Nuclear Information System (INIS)

    Zytoon, Ashraf Anas; Murakami, Koji; El-Kholy, Mohamed Ramdan; El-Shorbagy, Emad; Ebied, Osama

    2009-01-01

    Background: Malignant breast lesions usually are differentiated by FDG-PET with a semiquantitative FDG standardized uptake value (SUV) of 2.5. However, the frequency of breast cancer with an SUV of less than or equal to 2.5 is noteworthy, and often present diagnostic challenges. This study was undertaken to evaluate the accuracy of dual-time point FDG-PET/CT with FDG standardized uptake value (SUV) calculation in the characterization of such breast tumors. Methods: Forty-nine female patients with newly diagnosed breast cancer were found to have primary breast cancer with minimally increased FDG uptake and met the criteria for inclusion in this study by having borderline levels of increased FDG uptake (SUVmax less than or equal to 2.5) in the initial FDG-PET/CT images. Consequently, they underwent further delayed phase FDG-PET/CT scan for better evaluation of the disease. Results: Of the 49 cancer lesions; the majority were found to have rising or unvarying dual-time changes in SUVmax (75.5%). The median value of SUVmax increases by 25% between the early and delayed scan. The means ± S.D. of the SUVmax1, the SUVmax2, and the ΔSUVmax% were 1.2 ± 0.6%, 1.3 ± 0.9%, and 5.1 ± 22.4%, respectively. The receiver-operating-characteristic (ROC) analysis proved that the highest accuracy for characterization of malignant breast lesions was obtained when a ΔSUVmax% cut-off value 0.0% was used as criteria for malignant FDG uptake-change over time with sensitivity 75.5%, and false-positive rate 20.4%. Conclusion: These results suggested that dual-time FDG-PET/CT imaging with standardized uptake value (SUV) estimation can improve the accuracy of the test in the evaluation of breast cancer with low FDG uptake.

  5. Breast fibroadenoma with increased activity on 68Ga-DOTATATE PET/CT

    Science.gov (United States)

    Papadakis, Georgios Z.; Millo, Corina; Sadowski, Samira M.; Karantanas, Apostolos H.; Bagci, Ulas; Patronas, Nicholas J.

    2016-01-01

    Fibroadenoma is the most common benign breast tumor in women of reproductive age, carrying little to no risk of breast cancer development. We report on a case of a woman with history of neuroendocrine tumor (NET), who on follow-up imaging tests underwent whole-body PET/CT study using 68Ga-DOTATATE. The scan showed increased focal activity in the right breast, which was biopsied revealing a fibroadenoma. The presented data suggests cell surface over-expression of somatostatin receptors (SSTRs) by this benign breast tumor. Moreover, this finding emphasizes the need for cautious interpretation of 68Ga-DOTATATE avid breast lesions which could mimic malignancy in NET patients. PMID:27879489

  6. Breast Fibroadenoma With Increased Activity on 68Ga DOTATATE PET/CT.

    Science.gov (United States)

    Papadakis, Georgios Z; Millo, Corina; Sadowski, Samira M; Karantanas, Apostolos H; Bagci, Ulas; Patronas, Nicholas J

    2017-02-01

    Fibroadenoma is the most common benign breast tumor in women of reproductive age, carrying little to no risk of breast cancer development. We report on a case of a woman with history of neuroendocrine tumor who on follow-up imaging tests underwent whole-body PET/CT study using Ga DOTATATE. The scan showed increased focal activity in the right breast, which was biopsied revealing a fibroadenoma. The presented data suggests cell surface overexpression of somatostatin receptors by this benign breast tumor. Moreover, this finding emphasizes the need for cautious interpretation of Ga DOTATATE-avid breast lesions that could mimic malignancy in neuroendocrine tumor patients.

  7. Hybrid 18F-FDG PET/MRI might improve locoregional staging of breast cancer patients prior to neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Goorts, Briete; Nijnatten, Thiemo J.A. van; Voeoe, Stefan; Wildberger, Joachim E.; Lobbes, Marc B.I.; Kooreman, Loes F.S.; Boer, Maaike de; Keymeulen, Kristien B.M.I.; Aarnoutse, Romy; Smidt, Marjolein L.; Mottaghy, Felix M.

    2017-01-01

    Our purpose in this study was to assess the added clinical value of hybrid 18 F-FDG-PET/MRI compared to conventional imaging for locoregional staging in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). In this prospective study, primary invasive cT2-4 N0 or cT1-4 N+ breast cancer patients undergoing NAC were included. A PET/MRI breast protocol was performed before treatment. MR images were evaluated by a breast radiologist, blinded for PET images. PET images were evaluated by a nuclear physician. Afterwards, a combined PET/MRI report was written. PET/MRI staging was compared to conventional imaging, i.e., mammography, ultrasound and MRI. The proportion of patients with a modified treatment plan based on PET/MRI findings was analyzed. A total of 40 patients was included. PET/MRI was of added clinical value in 20.0% (8/40) of patients, changing the treatment plan in 10% and confirming the malignancy of suspicious lesions on MRI in another 10%. In seven (17.5%) patients radiotherapy fields were extended because of additional or affirmative PET/MRI findings being lymph node metastases (n = 5) and sternal bone metastases (n = 2). In one (2.5%) patient radiotherapy fields were reduced because of fewer lymph node metastases on PET/MRI compared to conventional imaging. Interestingly, all treatment changes were based on differences in number of lymph nodes suspicious for metastasis or number of distant metastasis, whereas differences in intramammary tumor extent were not observed. Prior to NAC, PET/MRI shows promising results for locoregional staging compared to conventional imaging, changing the treatment plan in 10% of patients and potentially replacing PET/CT or tissue sampling in another 10% of patients. (orig.)

  8. Simultaneous whole-body 18F-FDG PET-MRI in primary staging of breast cancer: A pilot study

    International Nuclear Information System (INIS)

    Taneja, Sangeeta; Jena, Amarnath; Goel, Reema; Sarin, Ramesh; Kaul, Sumaid

    2014-01-01

    Highlights: • Initial staging of breast cancer important in treatment planning and prognostication. • We assessed role of simultaneous 18 F-FDG PET-MRI in initial staging of breast cancer. • Primary, nodes and metastases on PET, MRI and PET-MRI for count and diagnostic confidence. • High diagnostic accuracy and confidence in detecting index and satellite lesions. • Comprehensive nodal and distant metastases staging with altered management (12 cases). - Abstract: Purpose: Accurate initial staging in breast carcinoma is important for treatment planning and for establishing the likely prognosis. The purpose of this study was to assess the utility of whole body simultaneous 18 F-FDG PET-MRI in initial staging of breast carcinoma. Methods: 36 patients with histologically confirmed invasive ductal carcinoma underwent simultaneous whole body 18 F-FDG PET-MRI on integrated 3 T PET-MR scanner (Siemens Biograph mMR) for primary staging. Primary lesion, nodes and metastases were evaluated on PET, MRI and PET-MRI for lesion count and diagnostic confidence (DC). Kappa co relation analysis was done to assess agreement between the satellite, nodal and metastatic lesions detected by PET and MRI. Histopathology, clinical/imaging follow-up served as the reference standard. Results: 36 patients with 37 histopathologically proven index breast cancer were retrospectively studied. Of 36 patients, 25 patients underwent surgery and 11 patients received systemic therapy. All index cancers were seen on PET and MR. Fused PET-MRI showed highest diagnostic confidence score of 5 as compared to PET (median 4; range 3–5) and MRI (median 4; range 4–5) alone. 2/36 (5.5%) patients were detected to have unsuspected contralateral synchronous cancer. 47 satellite lesions were detected on DCE MRI of which 23 were FDG avid with multifocality and multicentricity in 21 (58%) patients. Kappa co relation analysis revealed fair agreement for satellite lesion detection by the two modalities (κ

  9. Comparison of FDG-PET/CT and bone scintigraphy for detection of bone metastases in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Steffen; Heusner, Till; Forsting, Michael; Antoch, Gerald (Dept. of Diagnostic and Interventional Radiology and Neuroradiology, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)), email: steffen.hahn@uk-essen.de; Kuemmel, Sherko; Koeninger, Angelika (Dept. of Gynecology and Obstetrics, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany)); Nagarajah, James; Mueller, Stefan; Boy, Christian; Bockisch, Andreas; Stahl, Alexander (Dept. of Nuclear Medicine, Univ. Hospital Essen, Univ. Duisburg-Essen, Essen (Germany))

    2011-11-15

    Background Bone scintigraphy is the standard procedure for the detection of bone metastases in breast cancer patients. FDG-PET/CT has been reported to be a sensitive tool for tumor staging in different malignant diseases. However, its accuracy for the detection of bone metastases has not been compared to bone scintigraphy. Purpose To compare whole-body FDG-PET/CT and bone scintigraphy for the detection of bone metastases on a lesion basis in breast cancer patients. Material and Methods Twenty-nine consecutive women (mean age 58 years, range 35-78 years) with histologically proven breast cancer were assessed with bone scintigraphy and whole-body FDG-PET/CT. Twenty-one patients (72%) were suffering from primary breast cancer and eight patients (28%) were in aftercare with a history of advanced breast cancer. Both imaging procedures were assessed for bone metastases by a radiologist and a nuclear medicine physician. Concordant readings between bone scintigraphy and FDG-PET/CT were taken as true. Discordant readings were verified with additional MRI imaging in all patients and follow-up studies in most patients. Results A total of 132 lesions were detected on bone scintigraphy, FDG-PET/CT or both. According to the reference standard, 70/132 lesions (53%) were bone metastases, 59/132 lesions (45%) were benign, and three lesions (2%) remained unclear. The sensitivity of bone scintigraphy was 76% (53/70) compared to 96% (67/70) for FDG-PET/CT. The specificity of bone scintigraphy and FDG-PET/CT was 95% (56/59) and 92% (54/59), respectively. According to the reference standard bone metastases were present in eight out of the 29 patients (28%), whereas 20 patients (69%) were free of bone metastases. One (3%) patient had inconclusive readings on both modalities as well as on MRI and follow-up studies. Bone scintigraphy and FDG-PET/CT correctly identified seven out of eight patients with bone metastases and 20 out of 20 patients free of metastases. Conclusion On a lesion

  10. Development of an Anthropomorphic Breast Phantom for Combined PET, B-Mode Ultrasound and Elastographic Imaging

    Science.gov (United States)

    Dang, Jun; Frisch, Benjamin; Lasaygues, Philippe; Zhang, Dachun; Tavernier, Stefaan; Felix, Nicolas; Lecoq, Paul; Auffray, Etiennette; Varela, Joao; Mensah, Serge; Wan, Mingxi

    2011-06-01

    Combining the advantages of different imaging modalities leads to improved clinical results. For example, ultrasound provides good real-time structural information without any radiation and PET provides sensitive functional information. For the ongoing ClearPEM-Sonic project combining ultrasound and PET for breast imaging, we developed a dual-modality PET/Ultrasound (US) phantom. The phantom reproduces the acoustic and elastic properties of human breast tissue and allows labeling the different tissues in the phantom with different concentrations of FDG. The phantom was imaged with a whole-body PET/CT and with the Supersonic Imagine Aixplorer system. This system allows both B-mode US and shear wave elastographic imaging. US elastography is a new imaging method for displaying the tissue elasticity distribution. It was shown to be useful in breast imaging. We also tested the phantom with static elastography. A 6D magnetic positioning system allows fusing the images obtained with the two modalities. ClearPEM-Sonic is a project of the Crystal Clear Collaboration and the European Centre for Research on Medical Imaging (CERIMED).

  11. Combined use of 18F-FDG PET/CT and MRI for response monitoring of breast cancer during neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Pengel, Kenneth E.; Loo, Claudette E.; Koolen, Bas B.; Vogel, Wouter V.; Valdes Olmos, Renato A.; Wesseling, Jelle; Lips, Esther H.; Rutgers, Emiel J.T.; Vrancken Peeters, Marie Jeanne T.F.D.; Rodenhuis, Sjoerd; Gilhuijs, Kenneth G.A.

    2014-01-01

    To explore the potential complementary value of PET/CT and dynamic contrast-enhanced MRI in predicting pathological response to neoadjuvant chemotherapy (NAC) of breast cancer and the dependency on breast cancer subtype. We performed 18 F-FDG PET/CT and MRI examinations before and during NAC. The imaging features evaluated on both examinations included baseline and changes in 18 F-FDG maximum standardized uptake value (SUVmax) on PET/CT, and tumour morphology and contrast uptake kinetics on MRI. The outcome measure was a (near) pathological complete response ((near-)pCR) after surgery. Receiver operating characteristic curves with area under the curve (AUC) were used to evaluate the relationships between patient, tumour and imaging characteristics and tumour responses. Of 93 patients, 43 achieved a (near-)pCR. The responses varied among the different breast cancer subtypes. On univariate analysis the following variables were significantly associated with (near-)pCR: age (p = 0.033), breast cancer subtype (p < 0.001), relative change in SUVmax on PET/CT (p < 0.001) and relative change in largest tumour diameter on MRI (p < 0.001). The AUC for the relative reduction in SUVmax on PET/CT was 0.78 (95 % CI 0.68-0.88), and for the relative reduction in tumour diameter at late enhancement on MRI was 0.79 (95 % CI 0.70-0.89). The AUC increased to 0.90 (95 % CI 0.83-0.96) in the final multivariate model with PET/CT, MRI and breast cancer subtype combined (p = 0.012). PET/CT and MRI showed comparable value for monitoring response during NAC. Combined use of PET/CT and MRI had complementary potential. Research with more patients is required to further elucidate the dependency on breast cancer subtype. (orig.)

  12. MRI and PET/CT of patients with bone metastases from breast carcinoma

    International Nuclear Information System (INIS)

    Grankvist, J.; Fisker, R.; Iyer, V.; Fründ, E.T.; Simonsen, C.; Christensen, T.; Stenbygaard, L.; Ewertz, M.; Larsson, E.-M.

    2012-01-01

    3.0 Tesla magnetic resonance imaging (MRI) with diffusion-weighted imaging (DWI) was compared with combined 18F-fluorodeoxyglucose positron emission tomography and computed tomography (PET/CT) in patients with suspected bone metastases from breast cancer. A prospective clinical study was performed in 13 female breast cancer patients (mean age 61years; range 45–85 years). The spine was imaged in the sagittal plane with T1-weighted (T1), short tau inversion recovery (STIR), and T2-weighted fat-saturated (T2) sequences. The pelvis was imaged similarly in the coronal plane. Axial DWI was performed from the skull base to the mid-thigh. MRI and PET/CT were performed in all patients at a maximum interval of 10 working days and at least 14 days after chemotherapy. MRI was reviewed by two radiologists, and their consensus on potential metastases in 27 predefined locations was recorded. The predefined locations were the vertebral bodies (24), the left (1) and right (1) pelvic bones, and the sacral bone (1). The PET/CT was reviewed by a radiologists and a nuclear medicine physician. MRI detected 59 of the 60 active metastases found with our gold standard modality PET/CT. T1 had the highest sensitivity (98%) but rather low specificity (77%), but with the addition of STIR and DWI, the specificity increased to 95%. The additional metastases detected with MRI most likely represented postherapeutic residual scars without active tumour. In conclusion, 3.0 Tesla MRI with T1, STIR, and DWI is useful for the clinical evaluation of bone metastases from breast cancer and compares well to PET/CT.

  13. Appearance of untreated bone metastases from breast cancer on FDG PET/CT: importance of histologic subtype

    Energy Technology Data Exchange (ETDEWEB)

    Dashevsky, Brittany Z.; Parsons, Molly [Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Goldman, Debra A.; Goenen, Mithat [Memorial Sloan-Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Corben, Adriana D. [Memorial Sloan-Kettering Cancer Center, Department of Pathology, New York, NY (United States); Jochelson, Maxine S.; Ulaner, Gary A. [Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Memorial Sloan-Kettering Cancer Center, Department of Radiology, New York, NY (United States); Hudis, Clifford A. [Memorial Sloan-Kettering Cancer Center, Department of Medicine, New York, NY (United States); Morrow, Monica [Memorial Sloan-Kettering Cancer Center, Department of Surgery, New York, NY (United States)

    2015-10-15

    To determine if the histology of a breast malignancy influences the appearance of untreated osseous metastases on FDG PET/CT. This retrospective study was performed under IRB waiver. Our Hospital Information System was screened for breast cancer patients who presented with osseous metastases, who underwent FDG PET/CT prior to systemic therapy or radiotherapy from 2009 to 2012. Patients with invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), or mixed ductal/lobular (MDL) histology were included. Patients with a history of other malignancies were excluded. PET/CT was evaluated, blinded to histology, to classify osseous metastases on a per-patient basis as sclerotic, lytic, mixed lytic/sclerotic, or occult on CT, and to record SUVmax for osseous metastases on PET. Following screening, 95 patients who met the inclusion criteria (74 IDC, 13 ILC, and 8 MDL) were included. ILC osseous metastases were more commonly sclerotic and demonstrated lower SUVmax than IDC metastases. In all IDC and MDL patients with osseous metastases, at least one was FDG-avid. For ILC, all patients with lytic or mixed osseous metastases demonstrated at least one FDG-avid metastasis; however, in only three of seven patients were sclerotic osseous metastases apparent on FDG PET. The histologic subtype of breast cancer affects the appearance of untreated osseous metastases on FDG PET/CT. In particular, non-FDG-avid sclerotic osseous metastases were more common in patients with ILC than in patients with IDC. Breast cancer histology should be considered when interpreting non-FDG-avid sclerotic osseous lesions on PET/CT, which may be more suspicious for metastases (rather than benign lesions) in patients with ILC. (orig.)

  14. Appearance of untreated bone metastases from breast cancer on FDG PET/CT: importance of histologic subtype

    International Nuclear Information System (INIS)

    Dashevsky, Brittany Z.; Parsons, Molly; Goldman, Debra A.; Goenen, Mithat; Corben, Adriana D.; Jochelson, Maxine S.; Ulaner, Gary A.; Hudis, Clifford A.; Morrow, Monica

    2015-01-01

    To determine if the histology of a breast malignancy influences the appearance of untreated osseous metastases on FDG PET/CT. This retrospective study was performed under IRB waiver. Our Hospital Information System was screened for breast cancer patients who presented with osseous metastases, who underwent FDG PET/CT prior to systemic therapy or radiotherapy from 2009 to 2012. Patients with invasive ductal carcinoma (IDC), invasive lobular carcinoma (ILC), or mixed ductal/lobular (MDL) histology were included. Patients with a history of other malignancies were excluded. PET/CT was evaluated, blinded to histology, to classify osseous metastases on a per-patient basis as sclerotic, lytic, mixed lytic/sclerotic, or occult on CT, and to record SUVmax for osseous metastases on PET. Following screening, 95 patients who met the inclusion criteria (74 IDC, 13 ILC, and 8 MDL) were included. ILC osseous metastases were more commonly sclerotic and demonstrated lower SUVmax than IDC metastases. In all IDC and MDL patients with osseous metastases, at least one was FDG-avid. For ILC, all patients with lytic or mixed osseous metastases demonstrated at least one FDG-avid metastasis; however, in only three of seven patients were sclerotic osseous metastases apparent on FDG PET. The histologic subtype of breast cancer affects the appearance of untreated osseous metastases on FDG PET/CT. In particular, non-FDG-avid sclerotic osseous metastases were more common in patients with ILC than in patients with IDC. Breast cancer histology should be considered when interpreting non-FDG-avid sclerotic osseous lesions on PET/CT, which may be more suspicious for metastases (rather than benign lesions) in patients with ILC. (orig.)

  15. 64Cu-DOTA-trastuzumab PET imaging in patients with HER2-positive breast cancer.

    Science.gov (United States)

    Tamura, Kenji; Kurihara, Hiroaki; Yonemori, Kan; Tsuda, Hitoshi; Suzuki, Junko; Kono, Yuzuru; Honda, Natsuki; Kodaira, Makoto; Yamamoto, Harukaze; Yunokawa, Mayu; Shimizu, Chikako; Hasegawa, Koki; Kanayama, Yousuke; Nozaki, Satoshi; Kinoshita, Takayuki; Wada, Yasuhiro; Tazawa, Shusaku; Takahashi, Kazuhiro; Watanabe, Yasuyoshi; Fujiwara, Yasuhiro

    2013-11-01

    The purpose of this study was to determine the safety, distribution, internal dosimetry, and initial human epidermal growth factor receptor 2 (HER2)-positive tumor images of (64)Cu-DOTA-trastuzumab in humans. PET was performed on 6 patients with primary or metastatic HER2-positive breast cancer at 1, 24, and 48 h after injection of approximately 130 MBq of the probe (64)Cu-DOTA-trastuzumab. Radioactivity data were collected from the blood, urine, and normal-tissue samples of these 6 patients, and the multiorgan biodistribution and internal dosimetry of the probe were evaluated. Safety data were collected for all the patients after the administration of (64)Cu-DOTA-trastuzumab and during the 1-wk follow-up period. According to our results, the best timing for the assessment of (64)Cu-DOTA-trastuzumab uptake by the tumor was 48 h after injection. Radiation exposure during (64)Cu-DOTA-trastuzumab PET was equivalent to that during conventional (18)F-FDG PET. The radioactivity in the blood was high, but uptake of (64)Cu-DOTA-trastuzumab in normal tissues was low. In 2 patients, (64)Cu-DOTA-trastuzumab PET showed brain metastases, indicative of blood-brain barrier disruptions. In 3 patients, (64)Cu-DOTA-trastuzumab PET imaging also revealed primary breast tumors at the lesion sites initially identified by CT. The findings of this study indicated that (64)Cu-DOTA-trastuzumab PET is feasible for the identification of HER2-positive lesions in patients with primary and metastatic breast cancer. The dosimetry and pharmacologic safety results were acceptable at the dose required for adequate PET imaging.

  16. WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies

    International Nuclear Information System (INIS)

    Vedantham, S.

    2016-01-01

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  17. WE-FG-207A-01: Introduction to Dedicated Breast CT - Early Studies

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, S. [University of Massachusetts Medical School (United States)

    2016-06-15

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  18. {sup 18}F-FDG-PET/CT for systemic staging of newly diagnosed triple-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ulaner, Gary A.; Castillo, Raychel; Riedl, Christopher C.; Jochelson, Maxine S. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Goldman, Debra A.; Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Wills, Jonathan [Memorial Sloan Kettering Cancer Center, Department of Information Systems, New York, NY (United States); Pinker-Domenig, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States)

    2016-10-15

    National Comprehensive Cancer Network guidelines recommend {sup 18}F-FDG-PET/CT, in addition to standard staging procedures, for systemic staging of newly diagnosed stage III breast cancer patients. However, factors in addition to stage may influence PET/CT utility. As breast cancers that are negative for estrogen receptor, progesterone receptor, and human epidermal growth factor receptor (triple-negative breast cancer, or TNBC) are more aggressive and metastasize earlier than other breast cancers, we hypothesized that receptor expression may be one such factor. This study assesses {sup 18}F-FDG-PET/CT for systemic staging of newly diagnosed TNBC. In this Institutional Review Board-approved retrospective study, our Healthcare Information System was screened for patients with TNBC who underwent {sup 18}F-FDG-PET/CT in 2007-2013 prior to systemic or radiation therapy. Initial stage was determined from mammography, ultrasound, magnetic resonance imaging, and/or surgery, if performed prior to {sup 18}F-FDG-PET/CT. {sup 18}F-FDG-PET/CT was evaluated to identify unsuspected extra-axillary regional nodal and distant metastases, as well as unsuspected synchronous malignancies. Kaplan Meier survival estimates were calculated for initial stage IIB patients stratified by whether or not stage 4 disease was detected by {sup 18}F-FDG-PET/CT. A total of 232 patients with TNBC met inclusion criteria. {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 30 (13 %): 0/23 initial stage I, 4/82 (5 %) stage IIA, 13/87 (15 %) stage IIB, 4/23 (17 %) stage IIIA, 8/14 (57 %) stage IIIB, and 1/3 (33 %) stage IIIC. Twenty-six of 30 patients upstaged to IV by {sup 18}F-FDG-PET/CT were confirmed by pathology, with the remaining four patients confirmed by follow-up imaging. In addition, seven unsuspected synchronous malignancies were identified in six patients. Initial stage 2B patients who were upstaged to 4 by {sup 18}F-FDG-PET/CT had significantly shorter survival compared to

  19. Detection of synchronous parathyroid adenoma and breast cancer with {sup 18}F-fluorocholine PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Vorselaars, Wessel MCM; Kluijfthout, Wiuter P.; Vriens, Menno R; Van der Pol, Carmen C.; Rinkes, Inne HM Borel; Valk, Gerlof D.; De Keizer, Bart [University Medical Center Utrecht, Utrecht (Netherlands)

    2016-06-15

    A 71-year-old woman was referred to our tertiary care center for evaluation of asymptomatic recurrence of primary hyperparathyroidism. As per our protocol, the patient underwent neck/mediastinum {sup 18}F-fluorocholine (FCH) positron emission tomography-computed tomography (PET-CT) for localization. In our institution, FCH PET-CT is performed in patients with hyperparathyroidism and negative conventional imaging. FCH PET-CT is a promising new imaging modality for detection of hyperfunctioning parathyroid glands. As can be seen in the case presented, high FCH uptake was seen in a small breast cancer. Due to its favorable half-life and wide availability by its use as a localization technique for patients with prostate cancer and complicated hyperparathyroidism, FCH PET-CT may be a new promising modality in the imaging of breast cancer.

  20. Comparison of pharmacokinetic MRI and [18F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    International Nuclear Information System (INIS)

    Brix, G.; Henze, M.; Knopp, M.V.; Doll, J.; Hawighorst, H.; Lucht, R.; Junkermann, H.; Haberkorn, U.

    2001-01-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[ 18 F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  1. A meta-analysis of 18F-FDG PET or PET/CT for the evaluation of neoadjuvant chemotherapy in locally advanced breast cancer

    International Nuclear Information System (INIS)

    Xi Yun; Zhang Min; Guo Rui; Zhang Miao; Hu Jiajia; Li Biao

    2012-01-01

    Objective: To evaluate the accuracy and predictive value of 18 F-FDG PET or PET/CT in the assessment of neoadjuvant chemotherapy in locally advanced breast cancer by meta-analysis. Methods: Relevant studies were retrieved from PubMed, Embase, Cochrane and Wanfang, in English or Chinese. To ensure the homogeneity of all included studies, selection criteria were established and all the studies were scored according to a quality assessment of diagnostic accuracy studies (QUADAS) table. The combined Se, Sp, LR, diagnostic odds ratio (DOR), and AUC of PET and other conventional imaging techniques were compared. The assessment standard of neoadjuvant chemotherapy by conventional imaging techniques is tumor size change. Funnel plot and analysis with meta-regression were performed to explore the source of heterogeneity. Results: Sixteen eligible studies were included with a total of 662 subjects. The combined results were: (1) PET: Se PET 86.1% (247/287), Sp PET 69.6% (261/375), LR + PET 3.18, LR - PET 0.23, DOR PET 17.26; (2) Other imaging techniques: Se d 57.2% (91/159), Sp d 48.5% (50/103), LR + d 1.07, LR - d 0.87, DOR d 1.30. ROC analysis showed that Q * values of PET (Q PET * ) and other imaging techniques (Q d * ) were 0.8058 and 0.5328, respectively. Funnel plot showed that publication bias was not the main source of heterogeneity. Meta-regression results suggested that the year of publication might be one of the sources of heterogeneity (P=0.05). Conclusion: This meta-analysis suggests that, in the assessment of treatment response of neoadjuvant chemotherapy for breast cancer, FDG PET or PET/CT in monitoring the changes in glucose metabolism is more accurate than conventional imaging techniques in monitoring tumor size. (authors)

  2. Monitoring tumor response to neoadjuvant chemotherapy using MRI and 18F-FDG PET/CT in breast cancer subtypes

    NARCIS (Netherlands)

    Schmitz, Alexander M. Th; Teixeira, Suzana C.; Pengel, Kenneth E.; Loo, Claudette E.; Vogel, Wouter V.; Wesseling, Jelle; Rutgers, Emiel J. Th; Valdés Olmos, Renato A.; Sonke, Gabe S.; Rodenhuis, Sjoerd; Vrancken Peeters, Marie Jeanne T. F. D.; Gilhuijs, Kenneth G. A.

    2017-01-01

    To explore guidelines on the use of MRI and PET/CT monitoring primary tumor response to neoadjuvant chemotherapy (NAC), taking breast cancer subtype into account. In this prospective cohort study, 188 women were included with stages II and III breast cancer. MRI and 18F-FDG-PET/CT were acquired

  3. Hybrid {sup 18}F-FDG PET/MRI might improve locoregional staging of breast cancer patients prior to neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Goorts, Briete; Nijnatten, Thiemo J.A. van [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); Voeoe, Stefan; Wildberger, Joachim E.; Lobbes, Marc B.I. [Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); Kooreman, Loes F.S. [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Pathology, Maastricht (Netherlands); Boer, Maaike de [Maastricht University Medical Center, Department of Medical Oncology, Maastricht (Netherlands); Keymeulen, Kristien B.M.I. [Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Aarnoutse, Romy; Smidt, Marjolein L. [Maastricht University Medical Center, GROW - School for Oncology and Developmental Biology, Maastricht (Netherlands); Maastricht University Medical Center, Department of Surgery, P.O. Box 5800, Maastricht (Netherlands); Mottaghy, Felix M. [Maastricht University Medical Center, Department of Radiology and Nuclear Medicine, Maastricht (Netherlands); RWTH Aachen University Hospital, Department of Nuclear Medicine, Aachen (Germany)

    2017-10-15

    Our purpose in this study was to assess the added clinical value of hybrid {sup 18}F-FDG-PET/MRI compared to conventional imaging for locoregional staging in breast cancer patients undergoing neoadjuvant chemotherapy (NAC). In this prospective study, primary invasive cT2-4 N0 or cT1-4 N+ breast cancer patients undergoing NAC were included. A PET/MRI breast protocol was performed before treatment. MR images were evaluated by a breast radiologist, blinded for PET images. PET images were evaluated by a nuclear physician. Afterwards, a combined PET/MRI report was written. PET/MRI staging was compared to conventional imaging, i.e., mammography, ultrasound and MRI. The proportion of patients with a modified treatment plan based on PET/MRI findings was analyzed. A total of 40 patients was included. PET/MRI was of added clinical value in 20.0% (8/40) of patients, changing the treatment plan in 10% and confirming the malignancy of suspicious lesions on MRI in another 10%. In seven (17.5%) patients radiotherapy fields were extended because of additional or affirmative PET/MRI findings being lymph node metastases (n = 5) and sternal bone metastases (n = 2). In one (2.5%) patient radiotherapy fields were reduced because of fewer lymph node metastases on PET/MRI compared to conventional imaging. Interestingly, all treatment changes were based on differences in number of lymph nodes suspicious for metastasis or number of distant metastasis, whereas differences in intramammary tumor extent were not observed. Prior to NAC, PET/MRI shows promising results for locoregional staging compared to conventional imaging, changing the treatment plan in 10% of patients and potentially replacing PET/CT or tissue sampling in another 10% of patients. (orig.)

  4. A comparison of dedicated and hybrid PET imaging in detection of recurrences of colorectal cancer with [18]-FDG

    International Nuclear Information System (INIS)

    Montravers, F.; Grahek, D.; Kerrou, K.; Younsi, N.; Petegnief, Y.; Talbot, J.N.

    2002-01-01

    Full text: The aim of this study was to assess the clinical performances of FDG using a CDET system (hybrid dual-head MARCONI gamma camera with sodium iodine crystal 19 mm flick) or a dedicated PET system (C-PET, ADAC) for the detection of colorectal cancer recurrences. We report an experience of 4 years with CDET (July 1997 - July 2001) and of 1.5 years with PET (January 2000 - July 2001). After fasting for 6h or more, 3-5 MBq/kg (for 2D - CDET) or 2 MBq/kg (for 3D - PET) of [18F]-FDG were injected i.v. and imaging (whole-body scan and at least one tomoscintigram for CDET or scanning of the torso for PET) was started one hour later. Reconstruction was performed by an iterative algorithm. Attenuation correction by an external source was only available for PET. 304 examinations (ex) were performed with CDET and 164 with PET. 230 CDET cases and 73 PET cases are currently available according to histology or to follow-up. These examinations were performed for suspicion of recurrence (157 CDET cases, 39 PET cases), in search for other localization when one or more resectable lesion(s) was (were) known (48 CDET cases, 24 CDET cases) or for evaluation of the therapeutic efficacy (25 CDET cases, 10 PET cases). Globally, sensitivity was 89 % with CDET and 92 % with PET, specificity was 93 % with CDET and 100 % with PET and accuracy was 90 % with CDET and 93 % with PET. These results confirmed that FDG is a powerful tool for the detection of colorectal recurrences and showed that no significative difference in accuracy (chi2 = .75 ; p = .4) was detectable between the two modalities interpreted by the same team and both performed 1 hour after injection. (author)

  5. 18F-Fluoride PET/CT tumor burden quantification predicts survival in breast cancer.

    Science.gov (United States)

    Brito, Ana E; Santos, Allan; Sasse, André Deeke; Cabello, Cesar; Oliveira, Paulo; Mosci, Camila; Souza, Tiago; Amorim, Barbara; Lima, Mariana; Ramos, Celso D; Etchebehere, Elba

    2017-05-30

    In bone-metastatic breast cancer patients, there are no current imaging biomarkers to identify which patients have worst prognosis. The purpose of our study was to investigate if skeletal tumor burden determined by 18F-Fluoride PET/CT correlates with clinical outcomes and may help define prognosis throughout the course of the disease. Bone metastases were present in 49 patients. On multivariable analysis, skeletal tumor burden was significantly and independently associated with overall survival (p breast cancer patients (40 for primary staging and the remainder for restaging after therapy). Clinical parameters, primary tumor characteristics and skeletal tumor burden were correlated to overall survival, progression free-survival and time to bone event. The median follow-up time was 19.5 months. 18F-Fluoride PET/CT skeletal tumor burden is a strong independent prognostic imaging biomarker in breast cancer patients.

  6. Comparison of pharmacokinetic MRI and [{sup 18}F] fluorodeoxyglucose PET in the diagnosis of breast cancer: initial experience

    Energy Technology Data Exchange (ETDEWEB)

    Brix, G. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Henze, M. [Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany); Knopp, M.V.; Doll, J.; Hawighorst, H. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Lucht, R. [Dept. of Medical Radiation Hygiene, Federal Office for Radiation Protection, Oberschleissheim (Germany); Junkermann, H. [Dept. of Gynaecological Radiology, Univ. of Heidelberg (Germany); Haberkorn, U. [Research Program ' ' Radiological Diagnostics and Therapy' ' , German Cancer Research Center (DKFZ), Heidelberg (Germany); Dept. of Nuclear Medicine, Univ. of Heidelberg, Heidelberg (Germany)

    2001-10-01

    It was the aim of this methodology-oriented clinical pilot study to compare the potential of dynamic MRI and 2-[{sup 18}F]fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) for the detection and characterization of breast cancer. Fourteen women with suspicious breast lesions were examined. The MRI data were acquired with a turbo fast low-angle shot sequence and analyzed using a pharmacokinetic model. Emission data were detected in the sensitive 3D modus, iteratively reconstructed, and superimposed onto corresponding transmission images. In the 14 patients, 13 breast masses with a suspicious contrast enhancement and FDG uptake were detected. For these lesions, no statistically significant correlation between evaluated MR and PET parameters was found. Of the 9 histologically confirmed carcinomas, 8 were correctly characterized with MRI and PET. Two inflammatory lesions were concordantly classified as cancer. Moreover, dynamic MRI yielded another false-positive finding. In 6 patients, PET detected occult lymph node and/or distant metastases. Although both functional imaging techniques provide independent tissue information, the results concerning the diagnosis of primary breast lesions were almost identical. An advantage of PET, however, is its ability to localize lymph node involvement and distant metastases as an integral part of the examination. (orig.)

  7. An economic evaluation of positron emission tomography (PET) and positron emission tomography/computed tomography (PET/CT) for the diagnosis of breast cancer recurrence.

    Science.gov (United States)

    Auguste, P; Barton, P; Hyde, C; Roberts, T E

    2011-04-01

    To review the published economic studies that have evaluated positron emission tomography/computed tomography (PET/CT) in the treatment of recurrent breast cancer, and to develop and carry out a model-based economic evaluation to investigate the relative cost-effectiveness of PET/CT to detect breast cancer recurrence compared with conventional work-up. A systematic review of economic and diagnostic evidence for PET/CT in diagnosis of breast cancer recurrence. The original databases searched include MEDLINE (Ovid) (1950 to week 5 May 2009), EMBASE (Ovid) (1980 to 2009 week 22) and the NHS Economic Evaluation Database. An updated search was conducted for each database from May 2009 to week 4 April 2010. A decision tree was developed in TREEAGE software (TreeAge Software Inc., Williamstown, MA, USA). The relevant data on accuracy, sensitivity and specificity of each diagnostic test were linked in the model, to costs and the primary outcome measure, cost per quality-adjusted life-year (QALY). The model estimated the mean cost associated with each diagnostic procedure and assumed that patients entering the model were aged 50-75 years. The results of the cost-effectiveness analysis are presented in terms of the incremental cost-effectiveness ratios (ICERs). The ICER for the strategy of PET compared with conventional work-up was estimated at £29,300 per QALY; the ICER for PET/CT compared with PET was £ 31,000 per QALY; and the ICER for PET/CT combined with conventional work-up versus PET/CT was £ 42,100. Clearly, for each additional diagnostic test that is added to PET, the more expensive the package becomes, but also the more effective it becomes in terms of QALYs gained. The probabilistic sensitivity analysis shows that at a willingness-to-pay threshold of £ 20,000 per QALY, conventional work-up is the preferred option. Only data from indirect comparisons are available from the accuracy review, and there is some uncertainty about whether the data defining the

  8. Characterization and performance of monolithic detector blocks with a dedicated ASIC front-end readout for PET imaging of the human brain

    International Nuclear Information System (INIS)

    Rato Mendes, Pedro; Sarasola Martin, Iciar; Canadas, Mario; Garcia de Acilu, Paz; Cuypers, Robin; Perez, Jose Manuel; Willmott, Carlos

    2011-01-01

    We are developing a human brain PET scanner prototype compatible with MRI based on monolithic scintillator crystals, APD matrices and a dedicated ASIC front-end readout. In this work we report on the performance of individual detector modules and on the operation of such modules in PET coincidence. Results will be presented on the individual characterization of detector blocks and its ASIC front-end readout, with measured energy resolutions of 13% full-width half-maximum (FWHM) at 511 keV and spatial resolutions of the order of 2 mm FWHM. First results on PET coincidence performance indicate spatial resolutions as good as 2.1 mm FWHM for SSRB/FBP reconstruction of tomographic data obtained using a simple PET demonstrator based on a pair of monolithic detector blocks with ASIC readout.

  9. PET/CT in the complex estimation of the patient after breast cancer therapy - case report

    International Nuclear Information System (INIS)

    Ziolkowska, E.; Lozynska-Podhrebelna, D.; Zarzycka, M.; Malkowski, B.

    2007-01-01

    The connection of positron emission tomography (PET) and computer tomography (CT) with the use of FDG is finding wider application to the diagnostics, monitoring and treatment of breast cancer. The use of PET/CT improves the effectiveness of recurrence, metastases to the bones and distant internal organs diagnostics, and in some patients outdistances the presence of lesions which in conventional diagnostic examinations are described considerably later. This work presents the case of a 50-year-old woman with diagnosed breast cancer, after surgery treatment and complementary chemotherapy and radiotherapy. There was a suspicion of local recurrence in postoperative scar (in 18 th month after finished radiotherapy) and the absence of oncocytes in cytological examination in this patient and PET/CT was performed. The recurrence in postoperative scar and signs of dissemination to the bones and the liver was shown in this examination despite the negative tumour marker profile. CT and scintigraphy were performed additionally and they confirmed only the existence of metastatic changes in S1 vertebra and VI rib on the left side. Thanks to PET/CT examination both palliative radiotherapy and chemotherapy were applied immediately. After 5 months the control PET/CT examination was performed which showed a partial response to the applied treatment. The result of the examination and further growth of CA 15-3 marker were reasons for the inclusion of the next two series of chemotherapy. Bone scintigraphy, which was performed after completion of chemotherapy, showed the progression of metastatic changes. The patient was referred for radioisotopic treatment. The introduced case confirms the suitability of PET/CT in the complex assessment of a patient with diagnosed breast cancer. The use of PET/CT is a valuable element of recurrence and dissemination in neoplasmic disease quick diagnostics and directs the ways of the optimum antineoplasmic treatment. (authors)

  10. Utility of 18FDG-PET/CT in breast cancer diagnostics – a systematic review

    DEFF Research Database (Denmark)

    Warning, Karina; Hildebrandt, Malene; Christensen, Bent

    2011-01-01

    as a primary diagnostic procedure in breast cancer; but it has the potential to be useful for the detection of distant metastases and for monitoring response to chemotherapy in breast cancer patients. PET/CT should still be regarded as a supplement to conventional diagnostic procedures such as CT and MRI....

  11. First clinical experience with a dedicated MRI-guided high-intensity focused ultrasound system for breast cancer ablation

    Energy Technology Data Exchange (ETDEWEB)

    Merckel, Laura G.; Knuttel, Floor M.; Peters, Nicky H.G.M.; Mali, Willem P.T.M.; Bosch, Maurice A.A.J. van den [University Medical Center Utrecht, Department of Radiology, HP E 01.132, Utrecht (Netherlands); Deckers, Roel; Moonen, Chrit T.W.; Bartels, Lambertus W. [University Medical Center Utrecht, Image Sciences Institute, Utrecht (Netherlands); Dalen, Thijs van [Diakonessenhuis Utrecht, Department of Surgery, Utrecht (Netherlands); Schubert, Gerald [Philips Healthcare, Best (Netherlands); Weits, Teun [Diakonessenhuis Utrecht, Department of Radiology, Utrecht (Netherlands); Diest, Paul J. van [University Medical Center Utrecht, Department of Pathology, Utrecht (Netherlands); Vaessen, Paul H.H.B. [University Medical Center Utrecht, Department of Anesthesiology, Utrecht (Netherlands); Gorp, Joost M.H.H. van [Diakonessenhuis Utrecht, Department of Pathology, Utrecht (Netherlands)

    2016-11-15

    To assess the safety and feasibility of MRI-guided high-intensity focused ultrasound (MR-HIFU) ablation in breast cancer patients using a dedicated breast platform. Patients with early-stage invasive breast cancer underwent partial tumour ablation prior to surgical resection. MR-HIFU ablation was performed using proton resonance frequency shift MR thermometry and an MR-HIFU system specifically designed for breast tumour ablation. The presence and extent of tumour necrosis was assessed by histopathological analysis of the surgical specimen. Pearson correlation coefficients were calculated to assess the relationship between sonication parameters, temperature increase and size of tumour necrosis at histopathology. Ten female patients underwent MR-HIFU treatment. No skin redness or burns were observed in any of the patients. No correlation was found between the applied energy and the temperature increase. In six patients, tumour necrosis was observed with a maximum diameter of 3-11 mm. In these patients, the number of targeted locations was equal to the number of areas with tumour necrosis. A good correlation was found between the applied energy and the size of tumour necrosis at histopathology (Pearson = 0.76, p = 0.002). Our results show that MR-HIFU ablation with the dedicated breast system is safe and results in histopathologically proven tumour necrosis. (orig.)

  12. An algorithm for longitudinal registration of PET/CT images acquired during neoadjuvant chemotherapy in breast cancer: preliminary results.

    Science.gov (United States)

    Li, Xia; Abramson, Richard G; Arlinghaus, Lori R; Chakravarthy, Anuradha Bapsi; Abramson, Vandana; Mayer, Ingrid; Farley, Jaime; Delbeke, Dominique; Yankeelov, Thomas E

    2012-11-16

    By providing estimates of tumor glucose metabolism, 18F-fluorodeoxyglucose positron emission tomography (FDG-PET) can potentially characterize the response of breast tumors to treatment. To assess therapy response, serial measurements of FDG-PET parameters (derived from static and/or dynamic images) can be obtained at different time points during the course of treatment. However, most studies track the changes in average parameter values obtained from the whole tumor, thereby discarding all spatial information manifested in tumor heterogeneity. Here, we propose a method whereby serially acquired FDG-PET breast data sets can be spatially co-registered to enable the spatial comparison of parameter maps at the voxel level. The goal is to optimally register normal tissues while simultaneously preventing tumor distortion. In order to accomplish this, we constructed a PET support device to enable PET/CT imaging of the breasts of ten patients in the prone position and applied a mutual information-based rigid body registration followed by a non-rigid registration. The non-rigid registration algorithm extended the adaptive bases algorithm (ABA) by incorporating a tumor volume-preserving constraint, which computed the Jacobian determinant over the tumor regions as outlined on the PET/CT images, into the cost function. We tested this approach on ten breast cancer patients undergoing neoadjuvant chemotherapy. By both qualitative and quantitative evaluation, our constrained algorithm yielded significantly less tumor distortion than the unconstrained algorithm: considering the tumor volume determined from standard uptake value maps, the post-registration median tumor volume changes, and the 25th and 75th quantiles were 3.42% (0%, 13.39%) and 16.93% (9.21%, 49.93%) for the constrained and unconstrained algorithms, respectively (p = 0.002), while the bending energy (a measure of the smoothness of the deformation) was 0.0015 (0.0005, 0.012) and 0.017 (0.005, 0

  13. BI-RADS categorisation of 2708 consecutive nonpalpable breast lesions in patients referred to a dedicated breast care unit

    International Nuclear Information System (INIS)

    Hamy, A.S.; Giacchetti, S.; Cuvier, C.; Perret, F.; Bonfils, S.; Charveriat, P.; Hocini, H.; Espie, M.; Albiter, M.; Bazelaire, C. de; Roquancourt, A. de

    2012-01-01

    To determine the malignancy rate of nonpalpable breast lesions, categorised according to the Breast Imaging Reporting and Data System (BI-RADS) classification in the setting of a Breast Care Unit. All nonpalpable breast lesions from consecutive patients referred to a dedicated Breast Care Unit were prospectively reviewed and classified into 5 BI-RADS assessment categories (0, 2, 3, 4, and 5). A total of 2708 lesions were diagnosed by mammography (71.6%), ultrasound (8.7%), mammography and ultrasound (19.5%), or MRI (0.2%). The distribution of the lesions by BI-RADS category was: 152 in category 0 (5.6%), 56 in category 2 (2.1%), 742 in category 3 (27.4%), 1523 in category 4 (56.2%) and 235 in category 5 (8.7%). Histology revealed 570 malignant lesions (32.9%), 152 high-risk lesions (8.8%), and 1010 benign lesions (58.3%). Malignancy was detected in 17 (2.3%) category 3 lesions, 364 (23.9%) category 4 lesions and 185 (78.7%) category 5 lesions. Median follow-up was 36.9 months. This pragmatic study reflects the assessment and management of breast impalpable abnormalities referred for care to a specialized Breast Unit. Multidisciplinary evaluation with BI-RADS classification accurately predicts malignancy, and reflects the quality of management. This assessment should be encouraged in community practice appraisal. (orig.)

  14. Early metabolic response using FDG PET/CT and molecular phenotypes of breast cancer treated with neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Keam, Bhumsuk; Moon, Woo Kyung; Kim, Tae-You; Park, In Ae; Noh, Dong-Young; Chung, June-Key; Bang, Yung-Jue; Im, Seock-Ah; Koh, Youngil; Han, Sae-Won; Oh, Do-Youn; Cho, Nariya; Kim, Jee Hyun; Han, Wonshik; Kang, Keon Wook

    2011-01-01

    This study was aimed 1) to investigate the predictive value of FDG PET/CT (fluorine-18 fluorodeoxyglucose positron emission tomography/computed tomography) for histopathologic response and 2) to explore the results of FDG PET/CT by molecular phenotypes of breast cancer patients who received neoadjuvant chemotherapy. Seventy-eight stage II or III breast cancer patients who received neoadjuvant docetaxel/doxorubicin chemotherapy were enrolled in this study. FDG PET/CTs were acquired before chemotherapy and after the first cycle of chemotherapy for evaluating early metabolic response. The mean pre- and post-chemotherapy standard uptake value (SUV) were 7.5 and 3.9, respectively. The early metabolic response provided by FDG PET/CT after one cycle of neoadjuvant chemotherapy was correlated with the histopathologic response after completion of neoadjuvant chemotherapy (P = 0.002). Sensitivity and negative predictive value were 85.7% and 95.1%, respectively. The estrogen receptor negative phenotype had a higher pre-chemotherapy SUV (8.6 vs. 6.4, P = 0.047) and percent change in SUV (48% vs. 30%, P = 0.038). In triple negative breast cancer (TNBC), the pre-chemotherapy SUV was higher than in non-TNBC (9.8 vs. 6.4, P = 0.008). The early metabolic response using FDG PET/CT could have a predictive value for the assessment of histopathologic non-response of stage II/III breast cancer treated with neoadjuvant chemotherapy. Our findings suggest that the initial SUV and the decline in SUV differed based on the molecular phenotype. ClinicalTrials.gov: http://www.clinicaltrials.gov/ct2/show/NCT01396655

  15. Assessment of response to endocrine therapy using FDG PET/CT in metastatic breast cancer: a pilot study

    International Nuclear Information System (INIS)

    Mortazavi-Jehanno, Nina; Giraudet, Anne-Laure; Champion, Laurence; Edeline, Veronique; Madar, Olivier; Pecking, Alain Paul; Lerebours, Florence; Stanc, Elise Le; Bellet, Dominique; Alberini, Jean-Louis

    2012-01-01

    The purpose of this pilot study was to assess whether outcome in metastatic or recurrent breast cancer patients is related to metabolic response to endocrine therapy determined by 18 F-FDG PET/CT. The study group comprised 22 patients with breast cancer (age 58 ± 11 years, mean ± SD) who were scheduled to receive endocrine therapy. They were systematically assessed by PET/CT at baseline and after a mean of 10 ± 4 weeks for evaluation of response after induction. All patients demonstrated FDG-avid lesions on the baseline PET/CT scan. The metabolic response was assessed according to EORTC criteria and based on the mean difference in SUV max between the two PET/CT scans, and the patients were classified into four groups: complete or partial metabolic response, or stable or progressive metabolic disease (CMR, PMR, SMD and PMD, respectively). All patients were followed in our institution. Metastatic sites were localized in bone (n = 15), lymph nodes (n = 11), chest wall (n = 3), breast (n = 5), lung (n = 3), soft tissue (n = 1) and liver (n = 1). PMR was observed in 11 patients (50%), SMD in 5 (23%) and PMD in 6 (27%). The median progression-free survival (PFS) times were 20, 27 and 6 months in the PMR, SMD and PMD groups, respectively. PFS in the SMD group differed from that in the PMR and SMD groups (p < 0.0001). Metabolic response assessed by FDG PET/CT imaging in patients with metastatic breast cancer treated with endocrine therapy is predictive of the patients' PFS. (orig.)

  16. Assessment of response to endocrine therapy using FDG PET/CT in metastatic breast cancer: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Mortazavi-Jehanno, Nina; Giraudet, Anne-Laure; Champion, Laurence; Edeline, Veronique; Madar, Olivier; Pecking, Alain Paul [Institut Curie, Hopital Rene Huguenin, Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Institut Curie, Hopital Rene Huguenin, Service d' Oncologie Medicale, Saint-Cloud (France); Stanc, Elise Le [Hopital Foch, Service de Medecine Nucleaire, Suresnes (France); Bellet, Dominique [Institut Curie, Hopital Rene Huguenin, Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Institut Curie, Hopital Rene Huguenin, Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de Medecine, Versailles (France)

    2012-03-15

    The purpose of this pilot study was to assess whether outcome in metastatic or recurrent breast cancer patients is related to metabolic response to endocrine therapy determined by {sup 18}F-FDG PET/CT. The study group comprised 22 patients with breast cancer (age 58 {+-} 11 years, mean {+-} SD) who were scheduled to receive endocrine therapy. They were systematically assessed by PET/CT at baseline and after a mean of 10 {+-} 4 weeks for evaluation of response after induction. All patients demonstrated FDG-avid lesions on the baseline PET/CT scan. The metabolic response was assessed according to EORTC criteria and based on the mean difference in SUV{sub max} between the two PET/CT scans, and the patients were classified into four groups: complete or partial metabolic response, or stable or progressive metabolic disease (CMR, PMR, SMD and PMD, respectively). All patients were followed in our institution. Metastatic sites were localized in bone (n = 15), lymph nodes (n = 11), chest wall (n = 3), breast (n = 5), lung (n = 3), soft tissue (n = 1) and liver (n = 1). PMR was observed in 11 patients (50%), SMD in 5 (23%) and PMD in 6 (27%). The median progression-free survival (PFS) times were 20, 27 and 6 months in the PMR, SMD and PMD groups, respectively. PFS in the SMD group differed from that in the PMR and SMD groups (p < 0.0001). Metabolic response assessed by FDG PET/CT imaging in patients with metastatic breast cancer treated with endocrine therapy is predictive of the patients' PFS. (orig.)

  17. Disseminated osteomyelitis or bone metastases of breast cancer. 18F-FDG-PET/CT helps unravel an unusual presentation

    International Nuclear Information System (INIS)

    Mandegaran, Ramin; Wagner, Thomas; Debard, Alexa; Alvarez, Muriel; Marchou, Bruno; Massip, Patrice

    2014-01-01

    We present a case wherein striking 18 F-FDG-PET/CT findings initially considered consistent with recurrent disseminated skeletal metastases of breast cancer were later identified as an unusual presentation of disseminated chronic pyogenic osteomyelitis with Staphylococcus aureus and warneri identified on microbiological culture. A 76-year-old female with previous history of breast cancer presented with a 6-month history of pyrexia, myalgia and weight loss. Besides neutrophilia and elevated C-reactive protein, other blood indices, cultures and conventional imaging failed to identify the cause of pyrexia of unknown origin (PUO). 18 F-FDG-PET/CT demonstrated multiple widespread foci of intense FDG uptake in lytic lesions throughout the skeleton. Coupled with previous history of malignancy, findings were strongly suggestive of disseminated metastases of breast cancer. Through targeting an FDG avid lesion, 18 F-FDG-PET/CT aided CT-guided biopsy, which instead identified the lesions as chronic pyogenic osteomyelitis. Following prolonged antibiotic therapy, repeat 18 F-FDG-PET/CT demonstrated significant resolution of lesions. This case demonstrated an unusual presentation of disseminated osteomyelitis on 18 F-FDG-PET/CT and highlighted the use of 18 F-FDG-PET/CT as a trouble shooter in PUO but demonstrated that unusual presentations of benign or malignant pathologies cannot always reliably be differentiated on imaging alone without aid of tissue sampling. Furthermore, this case highlights the potential role 18 F-FDG-PET/CT could provide in assessing response to antibiotic therapy. (author)

  18. PET Probe-Guided Surgery in Patients with Breast Cancer: Proposal for a Methodological Approach

    Science.gov (United States)

    ORSARIA, PAOLO; CHIARAVALLOTI, AGOSTINO; FIORENTINI, ALESSANDRO; PISTOLESE, CHIARA; VANNI, GIANLUCA; VITTORIA GRANAI, ALESSANDRA; VARVARAS, DIMITRIOS; DANIELI, ROBERTA; SCHILLACI, ORAZIO; PETRELLA, GIUSEPPE; CLAUDIO BUONOMO, ORESTE

    2017-01-01

    Background: Although it is valuable for detecting distant metastases, identifying recurrence, and evaluating responses to chemotherapy, the role of 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (18F-FDG PET/CT) in assessing locoregional nodal status for initial staging of breast cancer has not yet been well-defined in clinical practice. In the current report, we describe a new PET probe-based clinical approach, with evaluation of the technical performance of a handheld high-energy gamma probe for intraoperative localization of breast carcinomas, and evaluation of lymph node metastases during radio-guided oncological surgery. Patients and Methods: Three patients underwent a PET/CT scan immediately prior to surgery following the standard clinical protocol. Intraoperatively, tumors were localized and resected with the assistance of a hand-held gamma probe. PET-guided assessment of the presence or absence of regional nodal spread of malignancy was compared with the reference standard of histopathological examination. Results: In all three cases, perioperative 18F-FDG PET/CT imaging and intraoperative gamma probe detection verified complete resection of the hypermetabolic lesions and demonstrated no additional suspicious occult disease. Conclusion: This innovative approach demonstrates great promise for providing real-time access to metabolic and morphological tumor information that may lead to an optimal disease-tailored approach. In carefully selected indications, a PET probe can be a useful adjunct in surgical practice, but further trials with a larger number of patients need to be performed to verify these findings. PMID:28064227

  19. Metastatic Breast Lesion to the Falx Detected with PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Harrison, Chester; Schuster, David M. [Emory Univ., Atlanta (United States)

    2012-06-15

    Intracranial dural metastasis is increasingly encountered in imaging. Autopsies conducted on patients with advanced metastatic disease demonstrate dural involvement in 9% of cases, with breast and prostate cancer the most common primaries. Awareness of this entity and imaging appearances is especially important in evaluating malignancies prone to dural metastasis. A 57-year-old woman with a strong family history of breast cancer initially presented after self-detection of a right breast lump. Subsequent mammogram and biopsies yielded a diagnosis of right infiltrating ductal carcinoma with a positive lymph node as well as left invasive lobular carcinoma. Initial staging PET-CT (not shown) at the time of diagnosis demonstrated no abnormal FDG uptake remote from the breast. Neoadjuvant chemotherapy was instituted, and a PET-CT was obtained to evaluate disease response, demonstrating an approximately 1.8 cm hypermetabolic intra-cranial mass, localized to the region of the anterior corpus callosum on axian PET (Fig. 1a), axial fused PET-CT (Fig. 1b), and sagittal fused PET-CT (Fig. 1c) with a maximum SUV of 15.9. There was associated bifrontal vasogenic edema (Fig. 1d) on the CT demonstrated on brain windows. Marked progression of disease was noted elsewhere, including hypermetabolic adenopathy and skeletal disease. A contrast-enhanced MRI of the brain was obtained demonstrating extensive T1 hypointensity, T2, and FLAIR (Fig. 2a) hyperintensity in the bilateral paramedian frontallobes representing vasogenic edema. Post-contrast imaging demonstrated three solidly enhancing masses in the areas of described vasogenic edema, one large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial and two sub-centimeter parenchymal lesions. The large extra-axial mass demonstrated homogeneous solid enhancement, in the midline anteriorly centered on the falx, just superior to the anterior corpus callosum. This measured 1.7cm transverse x 3.1cm AP x 2.4cm

  20. Alpha-V Integrin Targeted PET Imagining of Breast Cancer Angiogenesis and Lose-Dose Metronomic Anti-Angiogenic Chemotherapy Efficacy

    National Research Council Canada - National Science Library

    Chen, Xiaoyuan

    2005-01-01

    ...) To demonstrate the feasibility of PET/18F-RGD to image breast tumor growth, spread, and angiogenesis as well as quantifying av-integrin expression level during breast tumor neovascularization overtime. (3...

  1. {sup 18}F-FDG-PET/CT for systemic staging of patients with newly diagnosed ER-positive and HER2-positive breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ulaner, Gary A.; Castillo, Raychel [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Wills, Jonathan [Memorial Sloan Kettering Cancer Center, Department of Information Systems, New York, NY (United States); Goenen, Mithat; Goldman, Debra A. [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States)

    2017-08-15

    This study assesses {sup 18}F-FDG-PET/CT for patients with newly diagnosed estrogen receptor-positive/human epidermal growth factor receptor-negative (ER+/HER2-) and human epidermal growth factor receptor-positive (HER2+) breast cancer. In this Institutional Review Board-approved retrospective study, our Healthcare Information System was screened for patients with ER+/HER2- and HER2+ breast cancer who underwent {sup 18}F-FDG-PET/CT prior to systemic or radiation therapy. The initial stage was determined from mammography, ultrasound, magnetic resonance imaging, and/or surgery.{sup 18}F-FDG-PET/CT was evaluated to identify unsuspected extra-axillary regional nodal and distant metastases. The proportion of patients upstaged overall and stratified by stage and receptor phenotypes was calculated along with confidence intervals (CI). A total of 238 patients with ER+/HER2- and 245 patients with HER2+ who met inclusion criteria were evaluated. For patients with ER+/HER2-breast cancer, {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 3/71 (4%) initial stage IIA, 13/95 (14%) stage IIB, and 15/57 (26%) stage III. For patients with HER2+ breast cancer, {sup 18}F-FDG-PET/CT revealed unsuspected distant metastases in 3/72 (4%) initial stage IIA, 13/93 (14%) stage IIB, and 13/59 (22%) stage III. The overall upstaging rate for IIB was 14% (95% confidence interval (CI): 9-20%). {sup 18}F-FDG-PET/CT revealed distant metastases in 14% (95% CI: 9-20%) of patients with stage IIB ER+/HER2- and HER2+ breast cancer, which is similar to upstaging rates previously seen in patients with stage IIB triple-negative breast cancer (15%, 95% CI: 9-24%). The detection of unsuspected distant metastases in these patients alters treatment and prognosis. NCCN guidelines should consider adding patients with stage IIB breast cancer for consideration of systemic staging with {sup 18}F-FDG-PET/CT at the time of initial diagnosis. (orig.)

  2. Dual time point FDG-PET/CT imaging...; Potential tool for diagnosis of breast cancer

    International Nuclear Information System (INIS)

    Zytoon, A.A.; Murakami, K.; El-Kholy, M.R.; El-Shorbagy, E.

    2008-01-01

    Aim: This prospective study was designed to assess the utility of the dual time point imaging technique using 2- [ 18 F]-fluoro-2-deoxy-D-glucose (FDG) positron-emission tomography/computed tomography (PET/CT) to detect primary breast cancer and to determine whether it is useful for the detection of small and non-invasive cancers, as well as cancers in dense breast tissue. Methods: One hundred and eleven patients with newly diagnosed breast cancer underwent two sequential PET/CT examinations (dual time point imaging) for preoperative staging. The maximum standardized uptake value (SUVmax) of FDG was measured from both time points. The percentage change in SUVmax (ΔSUVmax%) between time points 1 (SUVmax1) and 2 (SUVmax2) was calculated. The patients were divided into groups: invasive (n = 82), non invasive (n = 29); large (>10 mm; n = 80), small (≤10 mm; n = 31); tumours in dense breasts (n = 61), and tumours in non-dense breasts (n = 50). The tumour:background (T:B) ratios at both time points were measured and the ΔSUVmax%, ΔT:B% values were calculated. All PET study results were correlated with the histopathology results. Results: Of the 111 cancer lesions, 88 (79.3%) showed an increase and 23 (20.7%) showed either no change [10 (9%)] or a decrease [13 (11.7%)] in the SUVmax over time. Of the 111 contralateral normal breasts, nine (8.1%) showed an increase and 102 (91.9%) showed either no change [17 (15.3%)] or a decrease [85 (76.6%)] in the SUVmax over time. The mean ± SD of SUVmax1, SUVmax2, Δ%SUVmax were 4.9 ± 3.6, 6.0 ± 4.5, and 22.6 ± 13.1% for invasive cancers, 4.1 ± 3.8, 4.4 ± 4.8, and -2.4 ± 18.5% for non-invasive cancers, 2.3 ± 1.9, 2.7 ± 2.3, and 12.9 ± 21.1% for small cancers, 5.6 ± 3.7, 6.8 ± 4.8, and 17.3 ± 17.1% for large cancers, 4.9 ± 3.7, 5.8 ± 4.8, and 15.1 ± 17.6% for cancers in dense breast, and 4.5 ± 3.6, 5.4 ± 4.5, and 17.2 ± 19.2% for cancers in non-dense breast. The receiver-operating characteristic (ROC) analysis

  3. Chronic thyroiditis in patients with advanced breast carcinoma: metabolic and morphologic changes on PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Tateishi, Ukihide [University of Texas, MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama (Japan); University of Texas MD Anderson Cancer Center, Division of Diagnostic Imaging, Houston, TX (United States); Gamez, Cristina; Yeung, Henry W.D.; Macapinlac, Homer A. [University of Texas, MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Dawood, Shaheenah; Cristofanilli, Massimo [University of Texas, MD Anderson Cancer Center, Division of Breast Medical Oncology, Houston, TX (United States); Inoue, Tomio [Yokohama City University Graduate School of Medicine, Department of Radiology, Yokohama (Japan)

    2009-06-15

    To investigate clinical implications of FDG uptake in the thyroid glands in patients with advanced breast carcinoma by comparing metabolic and morphologic patterns on positron emission tomography (PET)/computed tomography (CT). The institutional review board waived the requirement for informed consent. A retrospective analysis was performed in 146 women (mean age 54 years) with advanced breast carcinoma who received systemic treatment. All patients underwent PET-CT before and after treatment. All PET-CT studies were reviewed in consensus by two reviewers. Morphologic changes including volume and mean parenchymal density of the thyroid glands were evaluated. Maximum standardized uptake value (SUVmax) and total lesion glycolysis (TLG) were determined to evaluate metabolic changes. These parameters were compared between patients with chronic thyroiditis who received thyroid hormone replacement therapy and those who did not. Of the 146 patients, 29 (20%) showed bilaterally diffuse uptake in the thyroid glands on the baseline PET-CT scan. The SUVmax showed a linear relationship with volume (r = 0.428, p = 0.021) and the mean parenchymal density (r = -0.385, p = 0.039) of the thyroid glands. In 21 of the 29 patients (72%) with hypothyroidism who received thyroid hormone replacement therapy, the volume, mean parenchymal density, SUVmax, and TLG of the thyroid glands showed no significant changes. In contrast, 8 of the 29 patients (28%) who did not receive thyroid hormone replacement therapy showed marked decreases in SUVmax and TLG. Diffuse thyroid uptake on PET-CT represents active inflammation caused by chronic thyroiditis in patients with advanced breast carcinoma. Diffuse thyroid uptake may also address the concern about subclinical hypothyroidism which develops into overt disease during follow-up. (orig.)

  4. Doses to nuclear technicians in a dedicated PET/CT centre utilising 18F fluorodeoxyglucose (FDG)

    International Nuclear Information System (INIS)

    Seierstad, T.; Stranden, E.; Bjering, K.; Evensen, M.; Holt, A.; Michalsen, H. M.; Wetteland, O.

    2007-01-01

    The first dedicated PET/CT centre in Norway was established at the Norwegian Radiumhospital in Oslo in 2005. Knowing that the introductions of PET-isotopes in nuclear medicine give increased occupational radiation dose to the technicians, a study was carried out in order to map the doses to staff members during different working operations and to see if any dose reducing measures were needed. The results of the study are in good agreement with other studies, and a technician dose of 20-25 nSv per injected MBq of 18 F seems to be representative for such centres. For an average injected activity of 350 MBq per patient, the dose limit is reached after handling around 3000 patients annually. For an annual number of less than 500 patients at the centre and rotation of the staff, an annual individual dose for the technicians would realistically be less than 2-3 mSv. Even a major increase in the number of patients will not result in individual doses near the ICRP dose limit. (authors)

  5. Alpha-v Integrin Targeted PET Imaging of Breast Cancer Angiogenesis and Low-Dose Metronomic Anti-Angiogenic Chemotherapy Efficacy

    National Research Council Canada - National Science Library

    Chen, Xiaoyuan

    2006-01-01

    ...) To demonstrate the feasibility of PET/18F-RGD to image breast tumor growth spread and angiogenesis as well as quantifying alpha-v integrin expression level during breast tumor neovascularization over time. (3...

  6. Alpha-v Integrin Targeted PET Imaging of Breast Cancer Angiogenesis and Low-Dose Metronomic Anti-Angiogenic Chemotherapy Efficacy

    National Research Council Canada - National Science Library

    Chen, Xiaoyuan

    2007-01-01

    ...) To demonstrate the feasibility of PET/18F-RGD to image breast tumor growth spread and angiogenesis as well as quantifying alpha v-integrin expression level during breast tumor neovascularization over time. (3...

  7. Diffuse Intense {sup 18}F-FDG Uptake at PET in Unilateral Breast Related to Breastfeeding Practice

    Energy Technology Data Exchange (ETDEWEB)

    Ko, Kyung Hee; Jung, Hye Kyoung [Department of Radiololgy, CHA Bundang Medical Center, CHA University, Seongnam 463-712 (Korea, Republic of); Jeon, Tae Joo [Department of Nuclear Medicine, CHA Bundang Medical Center, CHA University, Seongnam 463-712 (Korea, Republic of)

    2013-07-01

    We present an interesting case of incidental diffuse fluorodeoxyglucose (FDG) uptake at PET in her left breast, related to atypical breastfeeding practice. Clinically, differential diagnoses of diffuse intense FDG uptake in unilateral breast include advanced breast cancer, breast lymphoma and inflammatory condition. However, normal physiologic lactation may also show increased FDG uptake in the breasts. Therefore, if we encounter that finding in daily practice, we should question the patient regarding unilateral breastfeeding. In addition, mammography and ultrasound would be helpful to confirm the diagnosis.

  8. Clinical impact of [18F]FDG-PET in patients with suspected recurrent breast cancer based on asymptomatically elevated tumor marker serum levels. A preliminary report

    International Nuclear Information System (INIS)

    Liu, Chiu-Shong; Lin, Cheng-Chieh; Kao, Chia-Hung; Yen, Ruoh-Fang

    2002-01-01

    The purpose of this study was to evaluate retrospectively the impact of [ 18 F]fluorodeoxyglucose positron emission tomography (FDG-PET) on the detection of recurrent breast cancer based on asymptomatically elevated tumor markers levels. Whole-body FDG-PET was performed in 30 patients with suspected recurrent breast cancer and asymptomatic tumor marker increase but negative or equivocal other imaging modality results. A blood sample was drawn in each case for marker assay (CA 15-3 and CEA) on the same day as the FDG-PET. All of these 30 asymptomatic patients had either CA 15-3>32 U/ml or CEA>5 ng/ml. The final diagnosis of recurrent breast cancer was established by operation/biopsy histopathological findings or clinical follow-up for >1 year by additional morphological imaging techniques. Among the 30 patients, the final diagnosis of recurrent breast cancer was established in 38 sites in 28 patients. FDG-PET accurately detected 35/38 sites in 25/28 patients with recurrence. The diagnostic sensitivity and accuracy of FDG-PET in patients with suspected recurrent breast cancer and asymptomatically elevated tumor markers were 96 and 90%, respectively. FDG-PET is a useful technique for detecting recurrent breast cancer suspected from asymptomatically elevated tumor markers levels and has an important clinical impact on the management of these patients. (author)

  9. QUANTITATIVE EVALUATION OF THERAPEUTIC RESPONSE BY FDG PET-CT IN METASTATIC BREAST CANCER

    Directory of Open Access Journals (Sweden)

    Dorothée eGOULON

    2016-05-01

    Full Text Available Purpose To assess the therapeutic response for metastatic breast cancer with 18F-FDG PET, this retrospective study aims to compare the performance of 6 different metabolic metrics with PERCIST, PERCIST with optimal thresholds and an image-based parametric approach.MethodsThirty six metastatic breast cancer patients underwent 128 PET scans and 123 lesions were identified. In a per-lesion and per-patient analysis, the performance of 6 metrics: SUVmax (maximum Standardized Uptake Value, SUVpeak, SAM (Standardized Added Metabolic activity, SUVmean, metabolic volume (MV, TLG (total lesion glycolysis and a parametric approach (SULTAN were determined and compared to the gold standard (defined by clinical assessment and biological and conventional imaging according RECIST 1.1. The evaluation was performed using PERCIST thresholds (for per-patient analysis only and optimal thresholds (determined by the Youden criterion from the Receiver Operating Characteristic curves.ResultsIn the per-lesion analysis, 210 pairs of lesion evolutions were studied. Using the optimal thresholds, SUVmax, SUVpeak, SUVmean, SAM and TLG were significantly correlated with the gold standard. SUVmax, SUVpeak and SUVmean reached the best sensitivity (91 %, 88 % and 83% respectively, specificity (93%, 95% and 97% respectively and negative predictive value (NPV, 90%, 88% and 83% respectively. For the per-patient analysis, 79 pairs of PET were studied. The optimal thresholds compared to the PERCIST threshold did not improve performance for SUVmax, SUVpeak and SUVmean. Only SUVmax, SUVpeak, SUVmean and TLG were correlated with the gold standard. SULTAN also performed equally: 83% sensitivity, 88% specificity and NPV 86%.ConclusionsThis study showed that SUVmax and SUVpeak were the best parameters for PET evaluation of metastatic breast cancer lesions. Parametric imaging is helpful in evaluating serial studies.

  10. Evaluation and comparison of contrast to noise ratio and signal to noise ratio according to change of reconstruction on breast PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Young Jae [Dept. of Nuclear Medicine, Seoul National University Hospital, Seoul (Korea, Republic of); Lee, Eul Kyu [Dept. of Radiology, Inje Paik University Hospital Jeo-dong, Seoul (Korea, Republic of); Kim, Ki Won [Dept. of Radiology, Kyung Hee University Hospital at Gang-dong, Seoul (Korea, Republic of); Jeong, Hoi Woun [Dept. of Radiological Technology, The Baekseok Culture University, Cheonan (Korea, Republic of); Lyu, Kwang Yeul; Park, Hoon Hee; Son, Jin Hyun; Min, Jung Whan [Dept. of Radiological Technology, The Shingu University, Sungnam (Korea, Republic of)

    2017-03-15

    The purpose of this study was to measure contrast to noise ratio (CNR) and signal to noise ratio (SNR) according to change of reconstruction from region of interest (ROI) in breast positron emission tomography- computed tomography (PET-CT), and to analyze the CNR and SNR statically. We examined images of breast PET-CT of 100 patients in a University-affiliated hospital, Seoul, Korea. Each patient's image of breast PET-CT were calculated by using Image J. Differences of CNR and SNR among four reconstruction algorithms were tested by SPSS Statistics21 ANOVA test for there was statistical significance (p<0.05). We have analysis socio-demographical variables, CNR and SNR according to reconstruction images, 95% confidence according to CNR and SNR of reconstruction and difference in a mean of CNR and SNR. SNR results, with the quality of distributions in the order of PSF{sub T}OF, Iterative and Iterative-TOF, FBP-TOF. CNR, with the quality of distributions in the order of PSF{sub T}OF, Iterative and Iterative-TOF, FBP-TOF. CNR and SNR of PET-CT reconstruction methods of the breast would be useful to evaluate breast diseases.

  11. (64)Cu-DOTA-trastuzumab PET imaging and HER2 specificity of brain metastases in HER2-positive breast cancer patients.

    Science.gov (United States)

    Kurihara, Hiroaki; Hamada, Akinobu; Yoshida, Masayuki; Shimma, Schuichi; Hashimoto, Jun; Yonemori, Kan; Tani, Hitomi; Miyakita, Yasuji; Kanayama, Yousuke; Wada, Yasuhiro; Kodaira, Makoto; Yunokawa, Mayu; Yamamoto, Harukaze; Shimizu, Chikako; Takahashi, Kazuhiro; Watanabe, Yasuyoshi; Fujiwara, Yasuhiro; Tamura, Kenji

    2015-01-01

    The purpose of this study was to determine whether brain metastases from HER2-positive breast cancer could be detected noninvasively using positron emission tomography (PET) with (64)Cu-1,4,7,10-tetraazacyclododecane-1,4,7,10-tetraacetic acid (DOTA)-trastuzumab. PET was performed on five patients with brain metastases from HER2-positive breast cancer, at 24 or 48 h after the injection of approximately 130 MBq of the probe (64)Cu-DOTA-trastuzumab. Radioactivity in metastatic brain tumors was evaluated based on PET images in five patients. Autoradiography, immunohistochemistry (IHC), and liquid chromatography-tandem mass spectrometry (LC-MS/MS) analysis were performed in one surgical case to confirm HER2 specificity of (64)Cu-DOTA-trastuzumab. Metastatic brain lesions could be visualized by (64)Cu-DOTA-trastuzumab PET in all of five cases, which might indicated that trastuzumab passes through the blood-brain barrier (BBB). The HER2 specificity of (64)Cu-DOTA-trastuzumab was demonstrated in one patient by autoradiography, immunohistochemistry, and LC-MS/MS. Cu-DOTA-trastuzumab PET could be a potential noninvasive procedure for serial identification of metastatic brain lesions in patients with HER2-positive breast cancer. UMIN000004170.

  12. Prediction of breast cancer recurrence using lymph node metabolic and volumetric parameters from {sup 18}F-FDG PET/CT in operable triple-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yong-il [CHA University, Department of Nuclear Medicine, CHA Bundang Medical Center, Seongnam (Korea, Republic of); Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Kim, Yong Joong [Veterans Health Service Medical Center, Seoul (Korea, Republic of); Paeng, Jin Chul; Cheon, Gi Jeong; Lee, Dong Soo [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Chung, June-Key [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Kang, Keon Wook [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Biomedical Sciences, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Triple-negative breast cancer has a poor prognosis. We evaluated several metabolic and volumetric parameters from preoperative {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) in the prognosis of triple-negative breast cancer and compared them with current clinicopathologic parameters. A total of 228 patients with triple-negative breast cancer (mean age 47.0 ± 10.8 years, all women) who had undergone preoperative PET/CT were included. The PET/CT metabolic parameters evaluated included maximum, peak, and mean standardized uptake values (SUVmax, SUVpeak, and SUVmean, respectively). The volumetric parameters evaluated included metabolic tumor volume (MTV) and total lesion glycolysis (TLG). Metabolic and volumetric parameters were evaluated separately for tumor (T) and lymph nodes (N). The prognostic value of these parameters was compared with that of clinicopathologic parameters. All lymph node metabolic and volumetric parameters showed significant differences between patients with and without recurrence. However, tumor metabolic and volumetric parameters showed no significant differences. In a univariate survival analysis, all lymph node metabolic and volumetric parameters (SUVmax-N, SUVpeak-N, SUVmean-N, MTV-N, and TLG-N; all P < 0.001), T stage (P = 0.010), N stage (P < 0.001), and TNM stage (P < 0.001) were significant parameters. In a multivariate survival analysis, SUVmax-N (P = 0.005), MTV (P = 0.008), and TLG (P = 0.006) with TNM stage (all P < 0.001) were significant parameters. Lymph node metabolic and volumetric parameters were significant predictors of recurrence in patients with triple-negative breast cancer after surgery. Lymph node metabolic and volumetric parameters were useful parameters for evaluating prognosis in patients with triple-negative breast cancer by {sup 18}F-FDG PET/CT, rather than tumor parameters. (orig.)

  13. Longitudinal, intermodality registration of quantitative breast PET and MRI data acquired before and during neoadjuvant chemotherapy: Preliminary results

    International Nuclear Information System (INIS)

    Atuegwu, Nkiruka C.; Williams, Jason M.; Li, Xia; Arlinghaus, Lori R.; Abramson, Richard G.; Chakravarthy, A. Bapsi; Abramson, Vandana G.; Yankeelov, Thomas E.

    2014-01-01

    Purpose: The authors propose a method whereby serially acquired DCE-MRI, DW-MRI, and FDG-PET breast data sets can be spatially and temporally coregistered to enable the comparison of changes in parameter maps at the voxel level. Methods: First, the authors aligned the PET and MR images at each time point rigidly and nonrigidly. To register the MR images longitudinally, the authors extended a nonrigid registration algorithm by including a tumor volume-preserving constraint in the cost function. After the PET images were aligned to the MR images at each time point, the authors then used the transformation obtained from the longitudinal registration of the MRI volumes to register the PET images longitudinally. The authors tested this approach on ten breast cancer patients by calculating a modified Dice similarity of tumor size between the PET and MR images as well as the bending energy and changes in the tumor volume after the application of the registration algorithm. Results: The median of the modified Dice in the registered PET and DCE-MRI data was 0.92. For the longitudinal registration, the median tumor volume change was −0.03% for the constrained algorithm, compared to −32.16% for the unconstrained registration algorithms (p = 8 × 10 −6 ). The medians of the bending energy were 0.0092 and 0.0001 for the unconstrained and constrained algorithms, respectively (p = 2.84 × 10 −7 ). Conclusions: The results indicate that the proposed method can accurately spatially align DCE-MRI, DW-MRI, and FDG-PET breast images acquired at different time points during therapy while preventing the tumor from being substantially distorted or compressed

  14. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    Science.gov (United States)

    Sportelli, G.; Belcari, N.; Camarlinghi, N.; Cirrone, G. A. P.; Cuttone, G.; Ferretti, S.; Kraan, A.; Ortuño, J. E.; Romano, F.; Santos, A.; Straub, K.; Tramontana, A.; Del Guerra, A.; Rosso, V.

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1 mm

  15. First full-beam PET acquisitions in proton therapy with a modular dual-head dedicated system

    International Nuclear Information System (INIS)

    Sportelli, G; Belcari, N; Camarlinghi, N; Ferretti, S; Kraan, A; Straub, K; Guerra, A Del; Rosso, V; Cirrone, G A P; Cuttone, G; Romano, F; Tramontana, A; Ortuño, J E; Santos, A

    2014-01-01

    During particle therapy irradiation, positron emitters with half-lives ranging from 2 to 20 min are generated from nuclear processes. The half-lives are such that it is possible either to detect the positron signal in the treatment room using an in-beam positron emission tomography (PET) system, right after the irradiation, or to quickly transfer the patient to a close PET/CT scanner. Since the activity distribution is spatially correlated with the dose, it is possible to use PET imaging as an indirect method to assure the quality of the dose delivery. In this work, we present a new dedicated PET system able to operate in-beam. The PET apparatus consists in two 10 cm × 10 cm detector heads. Each detector is composed of four scintillating matrices of 23 × 23 LYSO crystals. The crystal size is 1.9 mm × 1.9 mm × 16 mm. Each scintillation matrix is read out independently with a modularized acquisition system. The distance between the two opposing detector heads was set to 20 cm. The system has very low dead time per detector area and a 3 ns coincidence window, which is capable to sustain high single count rates and to keep the random counts relatively low. This allows a new full-beam monitoring modality that includes data acquisition also while the beam is on. The PET system was tested during the irradiation at the CATANA (INFN, Catania, Italy) cyclotron-based proton therapy facility. Four acquisitions with different doses and dose rates were analysed. In all cases the random to total coincidences ratio was equal or less than 25%. For each measurement we estimated the accuracy and precision of the activity range on a set of voxel lines within an irradiated PMMA phantom. Results show that the inclusion of data acquired during the irradiation, referred to as beam-on data, improves both the precision and accuracy of the range measurement with respect to data acquired only after irradiation. Beam-on data alone are enough to give precisions better than 1

  16. Normal physiologic and Benign foci with F-18 FDG avidity on PET/CT in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Park, Soon Ah; Lee, Kwang Man; Choi, Un Jong; Kim, Hun Soo; Kim, Hye Won; Song, Jeong Hoon [College of Medicine, Wonkwnag University, Iksan (Korea, Republic of)

    2010-12-15

    The aim of this study was to evaluate the physiologic and benign F-18 fluorodeoxyglucose (FDG) avid foci in patients with breast cancer. On 309 F-18 FDG PET/CT scans of 241 women with breast cancer, the hypermetabolic lesions compared with the surrounding normal region were evaluated retrospectively. Available reports of other relevant radiological imaging medical records, and follow-up PET/CT were reviewed for explanations of the abnormal uptake. Among the 70 physiologic foci, muscular uptake of the lower neck following the surgical and/or radiation therapy of ipsilateral breast (29%), hypermetabolic ovaries (16%) and uterine (10%) uptake during the ovulatory and menstrual phases during the normal menstrual cycle were identified, and also hypermetabolic brown fat in cold-induced thermogenesis (7%), non-specific bowel uptake (35%) were observed. Among the 147 benign lesions, sequelae of the chest wall and breasts following surgical and/or radiation therapy, were often observed (27%). Hypermetabolic thyroid glands were noted as adenomas and chronic thyroiditis (18%). Reactive hyperplasia of cervical or mediastinal lymph nodes (32%), degenerative osteoarthritis and healed fractures (15%), hypermetabolic benign lung lesions (6%) were observed. Altered physiologic and benign F-18 FDG uptake in the cervical muscle and chest wall following ipsilateral breast surgery or radiotherapy were common, and also normal physiologic uptake in ovary and uterus, brown fat, thyroid were considered as predominant findings in women patients with breast cancer. Knowledge of these findings might aid in the interpretation of FDG PET/CT in patients with breast cancer

  17. Local curvature analysis for classifying breast tumors: Preliminary analysis in dedicated breast CT

    International Nuclear Information System (INIS)

    Lee, Juhun; Nishikawa, Robert M.; Reiser, Ingrid; Boone, John M.; Lindfors, Karen K.

    2015-01-01

    Purpose: The purpose of this study is to measure the effectiveness of local curvature measures as novel image features for classifying breast tumors. Methods: A total of 119 breast lesions from 104 noncontrast dedicated breast computed tomography images of women were used in this study. Volumetric segmentation was done using a seed-based segmentation algorithm and then a triangulated surface was extracted from the resulting segmentation. Total, mean, and Gaussian curvatures were then computed. Normalized curvatures were used as classification features. In addition, traditional image features were also extracted and a forward feature selection scheme was used to select the optimal feature set. Logistic regression was used as a classifier and leave-one-out cross-validation was utilized to evaluate the classification performances of the features. The area under the receiver operating characteristic curve (AUC, area under curve) was used as a figure of merit. Results: Among curvature measures, the normalized total curvature (C_T) showed the best classification performance (AUC of 0.74), while the others showed no classification power individually. Five traditional image features (two shape, two margin, and one texture descriptors) were selected via the feature selection scheme and its resulting classifier achieved an AUC of 0.83. Among those five features, the radial gradient index (RGI), which is a margin descriptor, showed the best classification performance (AUC of 0.73). A classifier combining RGI and C_T yielded an AUC of 0.81, which showed similar performance (i.e., no statistically significant difference) to the classifier with the above five traditional image features. Additional comparisons in AUC values between classifiers using different combinations of traditional image features and C_T were conducted. The results showed that C_T was able to replace the other four image features for the classification task. Conclusions: The normalized curvature measure

  18. Clinical impact of [{sup 18}F]FDG-PET in patients with suspected recurrent breast cancer based on asymptomatically elevated tumor marker serum levels. A preliminary report

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Chiu-Shong; Lin, Cheng-Chieh; Kao, Chia-Hung [China Medical Coll., Taichung, Taiwan (China). Hospital; Shen, Yeh-You [Shin Kong Wu Ho-Su Memorial Hospital, Taipei, Taiwan (China); Yen, Ruoh-Fang [National Taiwan Univ., Taipei, Taiwan (China). Hospital

    2002-07-01

    The purpose of this study was to evaluate retrospectively the impact of [{sup 18}F]fluorodeoxyglucose positron emission tomography (FDG-PET) on the detection of recurrent breast cancer based on asymptomatically elevated tumor markers levels. Whole-body FDG-PET was performed in 30 patients with suspected recurrent breast cancer and asymptomatic tumor marker increase but negative or equivocal other imaging modality results. A blood sample was drawn in each case for marker assay (CA 15-3 and CEA) on the same day as the FDG-PET. All of these 30 asymptomatic patients had either CA 15-3>32 U/ml or CEA>5 ng/ml. The final diagnosis of recurrent breast cancer was established by operation/biopsy histopathological findings or clinical follow-up for >1 year by additional morphological imaging techniques. Among the 30 patients, the final diagnosis of recurrent breast cancer was established in 38 sites in 28 patients. FDG-PET accurately detected 35/38 sites in 25/28 patients with recurrence. The diagnostic sensitivity and accuracy of FDG-PET in patients with suspected recurrent breast cancer and asymptomatically elevated tumor markers were 96 and 90%, respectively. FDG-PET is a useful technique for detecting recurrent breast cancer suspected from asymptomatically elevated tumor markers levels and has an important clinical impact on the management of these patients. (author)

  19. Molecular imaging of small animals with dedicated PET tomographs

    International Nuclear Information System (INIS)

    Chatziioannou, A.F.

    2002-01-01

    Biological discovery has moved at an accelerated pace in recent years, with a considerable focus on the transition from in vitro to in vivo models. As a result, there has been a significant increase in the need to adapt clinical imaging methods, as well as for novel imaging technologies for biological research. Positron emission tomography (PET) is a clinical imaging modality that permits the use of positron-labeled molecular imaging probes for non-invasive assays of biochemical processes. The imaging procedure can be repeatedly performed before and after interventions, thereby allowing each animal to be used as its own control. Positron-labeled compounds that target a range of molecular targets have been and continue to be synthesized, with examples of biological processes ranging from receptors and synthesis of transmitters in cell communication, to metabolic processes and gene expression. In animal research, PET has been used extensively in the past for studies of non-human primates and other larger animals. New detector technology has improved spatial resolution, and has made possible PET scanning for the study of the most important modern molecular biology model, the laboratory mouse. This paper presents the challenges facing PET technology as applied to small animal imaging, provides a historical overview of the development of small animal PET systems, and discusses the current state of the art in small animal PET technology. (orig.)

  20. 18F-FDG PET/CT for initial staging in breast cancer patients. Is there a relevant impact on treatment planning compared to conventional staging modalities?

    International Nuclear Information System (INIS)

    Krammer, J.; Schnitzer, A.; Kaiser, C.G.; Buesing, K.A.; Schoenberg, S.O.; Wasser, K.; Sperk, E.; Brade, J.; Wasgindt, S.; Suetterlin, M.; Sutton, E.J.

    2015-01-01

    To evaluate the impact of whole-body 18 F-FDG PET/CT on initial staging of breast cancer in comparison to conventional staging modalities. This study included 102 breast cancer patients, 101 patients were eligible for evaluation. Preoperative whole-body staging with PET/CT was performed in patients with clinical stage ≥ T2 tumours or positive local lymph nodes (n = 91). Postoperative PET/CT was performed in patients without these criteria but positive sentinel lymph node biopsy (n = 10). All patients underwent PET/CT and a conventional staging algorithm, which included bone scan, chest X-ray and abdominal ultrasound. PET/CT findings were compared to conventional staging and the impact on therapeutic management was evaluated. PET/CT led to an upgrade of the N or M stage in overall 19 patients (19 %) and newly identified manifestation of breast cancer in two patients (2 %). PET/CT findings caused a change in treatment of 11 patients (11 %). This is within the range of recent studies, all applying conventional inclusion criteria based on the initial T and N status. PET/CT has a relevant impact on initial staging and treatment of breast cancer when compared to conventional modalities. Further studies should assess inclusion criteria beyond the conventional T and N status, e.g. tumour grading and receptor status. (orig.)

  1. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer

    DEFF Research Database (Denmark)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina

    2016-01-01

    PURPOSE: To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence....... PATIENTS AND METHODS: One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four...

  2. A False Positive {sup 18}F-FDG PET/CT Scan Caused by Breast Silicone Injection

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Chao Jung; Lee, Bi Fang; Yao, Wei Jen; Wu, Pei Shan; Chen, Wen Chung; Peng, Shu Lin; Chiu, Nan Tsing [Cheng Kung University Medical College and Hospital, Tainan (Turkmenistan)

    2009-04-15

    We present here the case of a 40-year-old woman with a greater than 10 year prior history of bilateral breast silicone injection and saline bag implantation. Bilateral palpable breast nodules were observed, but the ultrasound scan was suboptimal and the magnetic resonance imaging showed no gadolinium enhanced tumor. The {sup 18}F-FDG PET/CT scan showed a hypermetabolic nodule in the left breast with a 30% increase of {sup 18}F-FDG uptake on the delayed imaging, and this mimicked breast cancer. She underwent a left partial mastectomy and the pathology demonstrated a siliconoma.

  3. Scaling-law for the energy dependence of anatomic power spectrum in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Vedantham, Srinivasan; Shi, Linxi; Glick, Stephen J.; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2013-01-15

    Purpose: To determine the x-ray photon energy dependence of the anatomic power spectrum of the breast when imaged with dedicated breast computed tomography (CT). Methods: A theoretical framework for scaling the empirically determined anatomic power spectrum at one x-ray photon energy to that at any given x-ray photon energy when imaged with dedicated breast CT was developed. Theory predicted that when the anatomic power spectrum is fitted with a power curve of the form k f{sup -{beta}}, where k and {beta} are fit coefficients and f is spatial frequency, the exponent {beta} would be independent of x-ray photon energy (E), and the amplitude k scales with the square of the difference in energy-dependent linear attenuation coefficients of fibroglandular and adipose tissues. Twenty mastectomy specimens based numerical phantoms that were previously imaged with a benchtop flat-panel cone-beam CT system were converted to 3D distribution of glandular weight fraction (f{sub g}) and were used to verify the theoretical findings. The 3D power spectrum was computed in terms of f{sub g} and after converting to linear attenuation coefficients at monoenergetic x-ray photon energies of 20-80 keV in 5 keV intervals. The 1D power spectra along the axes were extracted and fitted with a power curve of the form k f{sup -{beta}}. The energy dependence of k and {beta} were analyzed. Results: For the 20 mastectomy specimen based numerical phantoms used in the study, the exponent {beta} was found to be in the range of 2.34-2.42, depending on the axis of measurement. Numerical simulations agreed with the theoretical predictions that for a power-law anatomic spectrum of the form k f{sup -{beta}}, {beta} was independent of E and k(E) =k{sub 1}[{mu}{sub g}(E) -{mu}{sub a}(E)]{sup 2}, where k{sub 1} is a constant, and {mu}{sub g}(E) and {mu}{sub a}(E) represent the energy-dependent linear attenuation coefficients of fibroglandular and adipose tissues, respectively. Conclusions: Numerical

  4. Library based x-ray scatter correction for dedicated cone beam breast CT

    International Nuclear Information System (INIS)

    Shi, Linxi; Zhu, Lei; Vedantham, Srinivasan; Karellas, Andrew

    2016-01-01

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  5. Library based x-ray scatter correction for dedicated cone beam breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Linxi; Zhu, Lei, E-mail: leizhu@gatech.edu [Nuclear and Radiological Engineering and Medical Physics Programs, The George W. Woodruff School of Mechanical Engineering, Georgia Institute of Technology, Atlanta, Georgia 30332 (United States); Vedantham, Srinivasan; Karellas, Andrew [Department of Radiology, University of Massachusetts Medical School, Worcester, Massachusetts 01655 (United States)

    2016-08-15

    Purpose: The image quality of dedicated cone beam breast CT (CBBCT) is limited by substantial scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose a library-based software approach to suppress scatter on CBBCT images with high efficiency, accuracy, and reliability. Methods: The authors precompute a scatter library on simplified breast models with different sizes using the GEANT4-based Monte Carlo (MC) toolkit. The breast is approximated as a semiellipsoid with homogeneous glandular/adipose tissue mixture. For scatter correction on real clinical data, the authors estimate the breast size from a first-pass breast CT reconstruction and then select the corresponding scatter distribution from the library. The selected scatter distribution from simplified breast models is spatially translated to match the projection data from the clinical scan and is subtracted from the measured projection for effective scatter correction. The method performance was evaluated using 15 sets of patient data, with a wide range of breast sizes representing about 95% of general population. Spatial nonuniformity (SNU) and contrast to signal deviation ratio (CDR) were used as metrics for evaluation. Results: Since the time-consuming MC simulation for library generation is precomputed, the authors’ method efficiently corrects for scatter with minimal processing time. Furthermore, the authors find that a scatter library on a simple breast model with only one input parameter, i.e., the breast diameter, sufficiently guarantees improvements in SNU and CDR. For the 15 clinical datasets, the authors’ method reduces the average SNU from 7.14% to 2.47% in coronal views and from 10.14% to 3.02% in sagittal views. On average, the CDR is improved by a factor of 1.49 in coronal views and 2.12 in sagittal

  6. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Science.gov (United States)

    Raylman, Raymond R.; Majewski, Stan; Smith, Mark F.; Proffitt, James; Hammond, William; Srinivasan, Amarnath; McKisson, John; Popov, Vladimir; Weisenberger, Andrew; Judy, Clifford O.; Kross, Brian; Ramasubramanian, Srikanth; Banta, Larry E.; Kinahan, Paul E.; Champley, Kyle

    2008-02-01

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 × 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 × 72 array of 2 × 2 × 15 mm3 LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 × 15 × 15 cm3. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 ± 0.09 mm (radial), 2.04 ± 0.08 mm (tangential) and 1.84 ± 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 ± 0.08 mm (radial), 2.16 ± 0.07 mm (tangential) and 1.87 ± 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps µCi-1 ml-1 (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  7. The positron emission mammography/tomography breast imaging and biopsy system (PEM/PET): design, construction and phantom-based measurements

    Energy Technology Data Exchange (ETDEWEB)

    Raylman, Raymond R [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Majewski, Stan [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Smith, Mark F [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Proffitt, James [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Hammond, William [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Srinivasan, Amarnath [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); McKisson, John [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Popov, Vladimir [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Weisenberger, Andrew [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Judy, Clifford O [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kross, Brian [Thomas Jefferson National Accelerator Facility, Newport News, VA (United States); Ramasubramanian, Srikanth [Center for Advanced Imaging, Department of Radiology, West Virginia University, Morgantown, WV (United States); Banta, Larry E [Department of Mechanical and Aerospace Engineering, West Virginia University, Morgantown, WV (United States); Kinahan, Paul E [Department of Radiology, University of Washington, Seattle, WA (United States); Champley, Kyle [Department of Radiology, University of Washington, Seattle, WA (United States)

    2008-02-07

    Tomographic breast imaging techniques can potentially improve detection and diagnosis of cancer in women with radiodense and/or fibrocystic breasts. We have developed a high-resolution positron emission mammography/tomography imaging and biopsy device (called PEM/PET) to detect and guide the biopsy of suspicious breast lesions. PET images are acquired to detect suspicious focal uptake of the radiotracer and guide biopsy of the area. Limited-angle PEM images could then be used to verify the biopsy needle position prior to tissue sampling. The PEM/PET scanner consists of two sets of rotating planar detector heads. Each detector consists of a 4 x 3 array of Hamamatsu H8500 flat panel position sensitive photomultipliers (PSPMTs) coupled to a 96 x 72 array of 2 x 2 x 15 mm{sup 3} LYSO detector elements (pitch = 2.1 mm). Image reconstruction is performed with a three-dimensional, ordered set expectation maximization (OSEM) algorithm parallelized to run on a multi-processor computer system. The reconstructed field of view (FOV) is 15 x 15 x 15 cm{sup 3}. Initial phantom-based testing of the device is focusing upon its PET imaging capabilities. Specifically, spatial resolution and detection sensitivity were assessed. The results from these measurements yielded a spatial resolution at the center of the FOV of 2.01 {+-} 0.09 mm (radial), 2.04 {+-} 0.08 mm (tangential) and 1.84 {+-} 0.07 mm (axial). At a radius of 7 cm from the center of the scanner, the results were 2.11 {+-} 0.08 mm (radial), 2.16 {+-} 0.07 mm (tangential) and 1.87 {+-} 0.08 mm (axial). Maximum system detection sensitivity of the scanner is 488.9 kcps {mu}Ci{sup -1} ml{sup -1} (6.88%). These promising findings indicate that PEM/PET may be an effective system for the detection and diagnosis of breast cancer.

  8. A Pilot Study for the Feasibility of F-18 FLT-PET in Locally Advanced Breast Cancer: Comparison with F-18 FDG-PET

    International Nuclear Information System (INIS)

    Lee, Jai Hyuen; Kim, Euy Nyong; Hong, Il Ki

    2008-01-01

    The aim of this study was to investigate the feasibility of 3'-[F-18]fluoro-3'-deoxythymidine positron emission tomography(FLT-PET) for the detection of locally advanced breast cancer and to compare the degree of FLT and 2'-deoxy-2'-[F-18]fluoro-d-glucose(FDG) uptake in primary tumor, lymph nodes and other normal organs. The study subjects consisted of 22 female patients (mean age; 42±6 years) with biopsy-confirmed infiltrating ductal carcinoma between Aug 2005 and Nov 2006. We performed conventional imaging workup, FDG-PET and FLT PET/CT. Average tumor size measured by MRI was 7.2±3.4 cm. With visual analysis, Tumor and Lymph node uptakes of FLT and FDG were determined by calculation of standardized uptake value (SUV) and tumor to background (TB) ratio. We compared FLT tumor uptake with FDG tumor uptake. We also investigated the correlation between FLT tumor uptake and FDG tumor uptake and the concordant rate with lymph node uptakes of FLT and FDG. FLT and FDG uptakes of bone marrow and liver were measured to compare the biodistribution of each other. All tumor lesions were visually detected in both FLT-PET and FDG-PET. There was no significant correlation between maximal tumor size by MRI and SUVmax of FLT-PET or FDG-PET (p>0.05). SUVmax and SUV75 (average SUV within volume of interest using 75% isocontour) of FLT-PET were significantly lower than those of FDG-PET in primary tumor (SUVmax; 6.3±5.2 vs 8.3±4.9, p=0.02 / SUV75; 5.3±4.3 vs 6.9 4.2, p=0.02). There is significant moderate correlation between uptake of FLT and FDG in primary tumor (SUVmax; rho=0.450, p=0.04 / SUV75; rho=0.472, p=0.03). But, TB ratio of FLT-PET was higher than that of FDG-PET(11.7±7.7 vs 6.3±3.8, p=0.001). The concordant rate between FLT and FDG uptake of lymph node was reasonably good (33/34). The FLT SUVs of liver and bone marrow were 4.2±1.2 and 8.3±4.9. The FDG SUVs of liver and bone marrow were 1.8±0.4 and 1.6±0.4. The uptakes of FLT were lower than those of FDG, but all

  9. Comparison of diffusion-weighted MR imaging and FDG PET/CT to predict pathological complete response to neoadjuvant chemotherapy in patients with breast cancer

    International Nuclear Information System (INIS)

    Park, Sang Hee; Moon, Woo Kyung; Cho, Nariya; Chang, Jung Min; Im, Seock-Ah; Park, In Ae; Kang, Keon Wook; Han, Wonshik; Noh, Dong-Young

    2012-01-01

    To compare the use of diffusion-weighted MR imaging (DWI) and 18 F-FDG PET/CT to predict pathological complete response (pCR) in breast cancer patients receiving neoadjuvant chemotherapy. Thirty-four women with 34 invasive breast cancers underwent DWI and PET/CT before and after chemotherapy and before surgery. The percentage changes in the apparent diffusion coefficient (ADC) and the standardised uptake value (SUV) were calculated, and the diagnostic performances for predicting pCR were evaluated using receiver operating characteristic (ROC) curve analysis. After surgery, 7/34 patients (20.6%) were found to have pCR. A z values for DWI, PET/CT and the combined use of DWI and PET/CT were 0.910, 0.873 and 0.944, respectively. The best cut-offs for differentiating pCR from non-pCR were a 54.9% increase in the ADC and a 63.9% decrease in the SUV. DWI showed 100% (7/7) sensitivity and 70.4% (19/27) specificity and PET/CT showed 100% sensitivity and 77.8% (21/27) specificity. When DWI and PET/CT were combined, there was a trend towards improved specificity compared with DWI. DWI and FDG PET/CT show similar diagnostic accuracy for predicting pCR to neoadjuvant chemotherapy in breast cancer patients. The combined use of DWI and FDG PET/CT has the potential to improve specificity in predicting pCR. (orig.)

  10. Breast Imaging Utilizing Dedicated Gamma Camera and (99m)Tc-MIBI: Experience at the Tel Aviv Medical Center and Review of the Literature Breast Imaging.

    Science.gov (United States)

    Even-Sapir, Einat; Golan, Orit; Menes, Tehillah; Weinstein, Yuliana; Lerman, Hedva

    2016-07-01

    The scope of the current article is the clinical role of gamma cameras dedicated for breast imaging and (99m)Tc-MIBI tumor-seeking tracer, as both a screening modality among a healthy population and as a diagnostic modality in patients with breast cancer. Such cameras are now commercially available. The technology utilizing a camera composed of a NaI (Tl) detector is termed breast-specific gamma imaging. The technology of dual-headed camera composed of semiconductor cadmium zinc telluride detectors that directly converts gamma-ray energy into electronic signals is termed molecular breast imaging. Molecular breast imaging system has been installed at the Department of Nuclear medicine at the Tel Aviv Sourasky Medical Center, Tel Aviv in 2009. The article reviews the literature well as our own experience. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. PET Imaging on Dynamic Metabolic Changes after Combination Therapy of Paclitaxel and the Traditional Chinese Medicine in Breast Cancer-Bearing Mice.

    Science.gov (United States)

    Chen, Yao; Wang, Ling; Liu, Hao; Song, Fahuan; Xu, Caiyun; Zhang, Kai; Chen, Qing; Wu, Shuang; Zhu, Yunqi; Dong, Ying; Zhou, Min; Zhang, Hong; Tian, Mei

    2018-04-01

    The aim of the study was to non-invasively evaluate the anticancer activity of a traditional Chinese medicine-Huaier, combined with paclitaxel (PTX) in breast cancer bearing mice by detecting dynamic metabolic changes with positron emission tomography (PET). Balb/c nude mice were randomly divided into one of the four groups: Huaier, PTX, PTX + Huaier, or the control. PET imaging with 2-deoxy-2-[ 18 F]fluoro-D-glucose ([ 18 F]FDG) was performed to monitor the metabolic changes in BT474 (luminal B) and MDA-MB-231 (triple-negative) breast cancer xenografts. Immunohistochemistry (IHC) study was performed immediately after the final PET scan to assess the expressions of phosphatidylinositol 3-kinase (PI3K), phospho-AKT (p-AKT), caspase-3, and vascular endothelial growth factor (VEGF). Compared to the control group, [ 18 F]FDG accumulation demonstrated a significant decrease in PTX + Huaier (p PET imaging could be a potential non-invasive approach to assess the metabolic changes after chemotherapy combined with traditional Chinese medicine in the breast cancer.

  12. Metastatic Brachial Plexopathy in a Case of Recurrent Breast Carcinoma Demonstrated on 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Tripathi, Madhavi; Das, Chandan J.; Srivastava, Anurag; Bal, ChandraSekhar; Malhotra, Arun

    2014-01-01

    This case highlights the importance of recognition of the pattern of metastatic brachialplexopathy in breast cancer patients undergoing 18 F-fluorodeoxyglucose ( 18 F-FDG) positron emission tomography/computed tomography (PET/CT) for evaluation of recurrent disease.This pattern can be appreciated on maximum intensity projection (MIP) and coronal 18 F-FDG PET/CT images as a linear extension of tracer activity from superomedial aspect(supra/infraclavicular) to lateral aspect of the axilla closely related to the subclavian/axillary vessels). A 35-year-old woman diagnosed with infiltrating ductal carcinoma of the right breast had undergone six cycles of neoadjuvant chemotherapy, followed by wide local incision and radiotherapy. She had local recurrence, for which she was operated upon and given chemotherapy. She presented to her oncologist with pain and swelling in the right breast, nodules in the right axilla and restriction of movement of the right upper limb. The patient was referred for 18 F-FDG PET/CT to evaluate the extent of recurrent/metastatic disease. Whole-body PET/CT was acquired 1 h following the intravenous injection of 296 MBq of 18 F-FDG on a Biograph mCT scanner (Siemens). Evaluation of the MIP image revealed abnormal FDG accumulation at multiple sites in the thorax, along with a linear pattern of FDG uptake in the right lateral aspect of the upper chest (Fig. 1a, arrow). The coronal fused PET/CT image revealed a linear pattern of FDG uptake corresponding to an ill-defined mass extending from just behind the right clavicle into the right axilla (arrow). In addition, abnormal FDG accumulation was seen in a soft tissue density mass in the upper outer quadrant of the right breast, skin of the right breast laterally, both pectoral muscles (discrete foci) and in a few subpectoral nodes. Soft tissue nodular opacities in both lungs showed FDG accumulation suggestive of pulmonary metastasis (Fig. 1b, thick arrow). The patient was referred for magnetic

  13. Diagnostic accuracy of {sup 18}F-FDG PET/CT compared with that of contrast-enhanced MRI of the breast at 3 T

    Energy Technology Data Exchange (ETDEWEB)

    Magometschnigg, Heinrich F.; Baltzer, Pascal A.; Fueger, Barbara; Helbich, Thomas H.; Weber, Michael [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Karanikas, Georgios [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Nuclear Medicine, Vienna (Austria); Dubsky, Peter [Medical University of Vienna, Department of Surgery, Vienna (Austria); Rudas, Margaretha [Medical University of Vienna, Department of Pathology, Vienna (Austria); Pinker, Katja [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Division of Molecular and Gender Imaging, Vienna (Austria); Molecular Imaging and Therapy Service, Memorial Sloan Kettering Cancer Center, New York (United States)

    2015-10-15

    To compare the diagnostic accuracy of prone {sup 18}F-FDG PET/CT with that of contrast-enhanced MRI (CE-MRI) at 3 T in suspicious breast lesions. To evaluate the influence of tumour size on diagnostic accuracy and the use of maximum standardized uptake value (SUV{sub MAX}) thresholds to differentiate malignant from benign breast lesions. A total of 172 consecutive patients with an imaging abnormality were included in this IRB-approved prospective study. All patients underwent {sup 18}F-FDG PET/CT and CE-MRI of the breast at 3 T in the prone position. Two reader teams independently evaluated the likelihood of malignancy as determined by {sup 18}F-FDG PET/CT and CE-MRI independently. {sup 18}F-FDG PET/CT data were qualitatively evaluated by visual interpretation. Quantitative assessment was performed by calculation of SUV{sub MAX}. Sensitivity, specificity, diagnostic accuracy, area under the curve and interreader agreement were calculated for all lesions and for lesions <10 mm. Histopathology was used as the standard of reference. There were 132 malignant and 40 benign lesions; 23 lesions (13.4 %) were <10 mm. Both {sup 18}F-FDG PET/CT and CE-MRI achieved an overall diagnostic accuracy of 93 %. There were no significant differences in sensitivity (p = 0.125), specificity (p = 0.344) or diagnostic accuracy (p = 1). For lesions <10 mm, diagnostic accuracy deteriorated to 91 % with both {sup 18}F-FDG PET/CT and CE-MRI. Although no significant difference was found for lesions <10 mm, CE-MRI at 3 T seemed to be more sensitive but less specific than {sup 18}F-FDG PET/CT. Interreader agreement was excellent (κ = 0.85 and κ = 0.92). SUV{sub MAX} threshold was not helpful in differentiating benign from malignant lesions. {sup 18}F-FDG PET/CT and CE-MRI at 3 T showed equal diagnostic accuracies in breast cancer diagnosis. For lesions <10 mm, diagnostic accuracy deteriorated, but was equal for {sup 18}F-FDG PET/CT and CE-MRI at 3 T. For lesions <10 mm, CE-MRI at 3 T seemed

  14. PET/CT in breast carcinoma, combined with sarcoidosis, imitating mediastinal lymph node metastases

    International Nuclear Information System (INIS)

    Garcheva, M.; Hadhyiska, V.; Bochev, P.

    2013-01-01

    PET/CT is a high sensitive, but low-specific method visualizing all the metabolic active processes. Fluoro-deoxyglucose (18F-FDG) uptake is high in tumors, as well as in infections, inflammations, granulomatous processes, post-radiotherapy alterations and in activated organs and tissues like brown fat, adrenals, thyroid, thymus, or bone marrow. This uptake can represent differential diagnostic problem. The clinical case is a young patient with invasive ductal and lobular breast carcinoma, after sectorial resection, without lymph node dissection. The chemotherapy was stopped after 3 courses due to thrombosis of vena cephalica. The local clinical status raises suspicion of recurrence, as the ultrasound. PET/CT was not conclusive about mediastinal lymph node involvement. The histology proves sarcoidosis, which frequently demonstrates symmetric 18F-FDG avid mediastinal and hilar lymph nodes. However the biopsy is mandatory, because of the low specificity of PET/CT for discrimination of this systemic disorder from tumor involvement. Keywords: PET/CT. Differential Diagnostic Problems

  15. Role of pharmacokinetic parameters derived with high temporal resolution DCE MRI using simultaneous PET/MRI system in breast cancer: A feasibility study

    Energy Technology Data Exchange (ETDEWEB)

    Jena, Amarnath, E-mail: drjena2002@gmail.com [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Taneja, Sangeeta; Singh, Aru; Negi, Pradeep; Mehta, Shashi Bhushan [Department of Molecular Imaging and Nuclear Medicine, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India); Sarin, Ramesh [Department of Surgical Oncology, Indraprastha Apollo Hospitals, Sarita Vihar, Delhi–Mathura Road, New Delhi 110076 (India)

    2017-01-15

    Highlights: • Simultaneous PET/MRI (with 3T MRI in the core) for quantitative pharmacokinetics. • Diagnostic accuracy of pharmacokinetic parameters like K{sup trans}, K{sub ep} and v{sub e} acquired through this system. • Incorporating high temporal resolution sequence with short acquisition time of 60 s within the routine DCE MRI in a simultaneous PET/MRI system. - Abstract: Purpose: To evaluate the reliability of pharmacokinetic parameters like K{sup trans}, Kep and v{sub e} derived through DCE MRI breast protocol using 3 T Simultaneous PET/MRI (3 Tesla Positron Emission Tomography/Magnetic Resonance Imaging) system in distinguishing benign and malignant lesions. Materials and methods: High temporal resolution DCE (Dynamic Contrast Enhancement) MRI performed as routine breast MRI for diagnosis or as a part of PET/MRI for cancer staging using a 3 T simultaneous PET/MRI system in 98 women having 109 breast lesions were analyzed for calculation of pharmacokinetic parameters (K{sup trans}, v{sub e}, and Kep) at 60 s time point using an in-house developed computation scheme. Results: Receiver operating characteristic (ROC) curve analysis revealed a cut off value for K{sup trans}, Kep, v{sub e} as 0.50, 2.59, 0.15 respectively which reliably distinguished benign and malignant breast lesions. Data analysis revealed an overall accuracy of 94.50%, 79.82% and 87.16% for K{sup trans}, Kep, v{sub e} respectively. Introduction of native T1 normalization with an externally placed phantom showed a higher accuracy (94.50%) than without native T1 normalization (93.50%) with an increase in specificity of 87% vs 84%. Conclusion: Overall the results indicate that reliable measurement of pharmacokinetic parameters with reduced acquisition time is feasible in a 3TMRI embedded PET/MRI system with reasonable accuracy and application may be extended to exploit the potential of simultaneous PET/MRI in further work on breast cancer.

  16. Monitoring tumor response to neoadjuvant chemotherapy using MRI and 18F-FDG PET/CT in breast cancer subtypes

    NARCIS (Netherlands)

    Schmitz, Alexander M Th; Teixeira, Suzana C; Pengel, Kenneth E; Loo, Claudette E; Vogel, Wouter V; Wesseling, Jelle; Rutgers, Emiel J Th; Valdés Olmos, Renato A; Sonke, Gabe S; Rodenhuis, Sjoerd; Vrancken Peeters, Marie Jeanne T F D; Gilhuijs, Kenneth G A

    2017-01-01

    PURPOSE: To explore guidelines on the use of MRI and PET/CT monitoring primary tumor response to neoadjuvant chemotherapy (NAC), taking breast cancer subtype into account. MATERIALS AND METHODS: In this prospective cohort study, 188 women were included with stages II and III breast cancer. MRI and

  17. III Frontier of accurate diagnosis of breast cancer. 1. Present state and prospect of preoperative diagnosis of progression, differential diagnosis of benign and malign natures, and efficacy evaluation of neoadjuvant chemotherapy. 2) Clinical efficacy and problem of FDG-PET (PET/CT) in breast cancer

    International Nuclear Information System (INIS)

    Kitajima, Kazuhiro; Kaji, Yasushi; Hayashi, Mitsuhiro; Sunagawa, Masakatsu; Murakami, Kouji; Yamazaki, Erena

    2008-01-01

    On authors' experience and literature, clinical efficacy and limitation of fluorodeoxyglucose-positron emission tomography (FDG-PET) (PET/CT) in the breast cancer are described and discussed for detection of the primary lesion, preoperative staging and lymph node diagnosis, diagnosis of recurrence and remote metastasis, evaluation of therapeutic efficacy, and prediction of prognosis. For routine breast cancer screening, authors think PET/CT is not always effective because of many false positive/negative findings. PET/CT and subsequent CT with iodine contrast media are thought to be useful for preoperative staging and planning in conservative surgery though detection of micro-metastatic nodes are often difficult. PET is reportedly superior to 99m Tc-MDP scintigraphy in bone metastasis detection, but which conceivably depends on the nature (osteogenic/osteolytic) of the lesion. For recurrence and remote metastasis, the diagnostic sensitivity, specificity and accuracy of PET/CT are reported to be as high as 84-98, 84-94 and 86-97%, respectively. Standardization of PET/CT monitoring is now necessary to evaluate the therapeutic efficacy. SUV which indicates the degree of FDG accumulation in the lesion, can be used for prediction of prognosis in future. Awaited is the development of more effective PET/CT apparatus and agent (instead of FDG) for detection of small metastatic lesions, axillary lymphatic metastasis, and viable focus after therapeutic treatments. (R.T.)

  18. A study of the changes of breast uptake in menstrual cycle on 18F-FDG PET/CT

    International Nuclear Information System (INIS)

    Park, Hoon Hee; Tak, Yeo Jin; Park, Min Soo; Lee, Ju Young

    2015-01-01

    18 F-FDG PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; however, there have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on 18 F-FDG PET/CT. 160 females (34±3.5 years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used a s PET/CT. We analyzed SUVs on a ccumulated r egion on b reast, and 3 nuclear medicine specialists did the Blind test. SUVs on the Breast were flow phase (1.64±0.25), proliferative phase (0.93±0.28), ovulatory phase (1.66±0.26) and secretory phase (1.77±0.28). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast’s uptake was equal to lung (Grade Ⅰ); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle

  19. Feasibility of a brain-dedicated PET-MRI system using four-layer DOI detectors integrated with an RF head coil

    International Nuclear Information System (INIS)

    Nishikido, F.; Obata, T.; Shimizu, K.; Suga, M.; Inadama, N.; Tachibana, A.; Yoshida, E.; Ito, H.; Yamaya, T.

    2014-01-01

    We are developing a PET-MRI system which consists of PET detectors integrated with the head coil of the MRI in order to realize high spatial resolution and high sensitivity in simultaneous measurements. In the PET-MRI system, the PET detectors which consist of a scintillator block, photo-detectors and front-end circuits with four-layer depth-of-interaction (DOI) encoding capability are placed close to the measured object. Therefore, the proposed system can achieve high sensitivity without degradation of spatial resolution at the edge of the field-of-view due to parallax error thanks to the four-layer DOI capability. In this paper, we fabricated a prototype system which consists of a prototype four-layer DOI-PET detector, a dummy PET detector and a prototype birdcage type head coil. Then we used the prototype system to evaluate the performance of the four-layer DOI-PET detector and the reciprocal influence between the PET detectors and MRI images. The prototype DOI-PET detector consists of six monolithic multi-pixel photon counter (MPPC) arrays (S11064-050P), a readout circuit board, two scintillator blocks and a copper shielding box. Each scintillator block consists of four layers of Lu 1.8 Gd 0.2 SiO 5 :Ce (LGSO) scintillators and reflectors are inserted between the scintillation crystals. The dummy detector has all these components except the two scintillator blocks. The head coil is dedicated to a 3.0 T MRI (MAGNETOM Verio, Siemens) and the two detectors are mounted in gaps between head coil elements. Energy resolution and crystal identification performance of the prototype four-layer DOI-PET detector were evaluated with and without MRI measurements by the gradient echo and spin echo methods. We identified crystal elements in all four layers from a 2D flood histogram and energy resolution of 15–18% was obtained for single crystal elements in simultaneous measurements. The difference between the average energy resolutions and photo-peak positions with and

  20. Functional imaging of human epidermal growth factor receptor 2-positive metastatic breast cancer using (64)Cu-DOTA-trastuzumab PET.

    Science.gov (United States)

    Mortimer, Joanne E; Bading, James R; Colcher, David M; Conti, Peter S; Frankel, Paul H; Carroll, Mary I; Tong, Shan; Poku, Erasmus; Miles, Joshua K; Shively, John E; Raubitschek, Andrew A

    2014-01-01

    Women with human epidermal growth factor receptor 2 (HER2)-positive breast cancer are candidates for treatment with the anti-HER2 antibody trastuzumab. Assessment of HER2 status in recurrent disease is usually made by core needle biopsy of a single lesion, which may not represent the larger tumor mass or other sites of disease. Our long-range goal is to develop PET of radiolabeled trastuzumab for systemically assessing tumor HER2 expression and identifying appropriate use of anti-HER2 therapies. The purpose of this study was to evaluate PET/CT of (64)Cu-DOTA-trastuzumab for detecting and measuring tumor uptake of trastuzumab in patients with HER2-positive metastatic breast cancer. Eight women with biopsy-confirmed HER2-positive metastatic breast cancer and no anti-HER2 therapy for 4 mo or longer underwent complete staging, including (18)F-FDG PET/CT. For 6 of the 8 patients, (64)Cu-DOTA-trastuzumab injection (364-512 MBq, 5 mg of trastuzumab) was preceded by trastuzumab infusion (45 mg). PET/CT (PET scan duration 1 h) was performed 21-25 (day 1) and 47-49 (day 2) h after (64)Cu-DOTA-trastuzumab injection. Scan fields of view were chosen on the basis of (18)F-FDG PET/CT. Tumor detection sensitivity and uptake analyses were limited to lesions identifiable on CT; lesions visualized relative to adjacent tissue on PET were considered PET-positive. Radiolabel uptake in prominent lesions was measured as maximum single-voxel standardized uptake value (SUVmax). Liver uptake of (64)Cu was reduced approximately 75% with the 45-mg trastuzumab predose, without significant effect on tumor uptake. The study included 89 CT-positive lesions. Detection sensitivity was 77%, 89%, and 93% for day 1, day 2, and (18)F-FDG, respectively. On average, tumor uptake was similar for (64)Cu-DOTA-trastuzumab and (18)F-FDG (SUVmax and range, 8.1 and 3.0-22.5 for day 1 [n = 48]; 8.9 and 0.9-28.9 for day 2 [n = 38]; 9.7 and 3.3-25.4 for (18)F-FDG [n = 56]), but same-lesion SUVmax was not correlated

  1. WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

    International Nuclear Information System (INIS)

    Karellas, A.

    2016-01-01

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  2. WE-FG-207A-05: Dedicated Breast CT as a Diagnostic Imaging Tool: Physics and Clinical Feasibility

    Energy Technology Data Exchange (ETDEWEB)

    Karellas, A. [University of Massachusetts Medical School (United States)

    2016-06-15

    Mammography-based screening has been a valuable imaging tool for the early detection of non-palpable lesions and has contributed to significant reduction in breast cancer associated mortality. However, the breast imaging community recognizes that mammography is not ideal, and in particular is inferior for women with dense breasts. Also, the 2-D projection of a 3-D organ results in tissue superposition contributing to false-positives. The sensitivity of mammography is breast-density dependent. Its sensitivity, especially in dense breasts, is low due to overlapping tissue and the fact that normal breast tissue, benign lesions and breast cancers all have similar “densities”, making lesion detection more difficult. We ideally need 3-D imaging for imaging the 3-D breast. MRI is 3-D, whole breast ultrasound is 3-D, digital breast tomosynthesis is called 3-D but is really “pseudo 3-D” due to poor resolution along the depth-direction. Also, and importantly, we need to be able to administer intravenous contrast agents for optimal imaging, similar to other organ systems in the body. Dedicated breast CT allows for 3-D imaging of the uncompressed breast. In current designs, the patient is positioned prone on the table and the breast is pendant through an aperture and the scan takes approximately 10 seconds [O’Connell et al., AJR 195: 496–509, 2010]. Almost on the heels of the invention of CT itself, work began on the development of dedicated breast CT. These early breast CT systems were used in clinical trials and the results from comparative performance evaluation of breast CT and mammography for 1625 subjects were reported in 1980 [Chang et al., Cancer 46: 939–46, 1980]. However, the technological limitations at that time stymied clinical translation for decades. Subsequent to the landmark article in 2001 [Boone et al., Radiology 221: 657–67, 2001] that demonstrated the potential feasibility in terms of radiation dose, multiple research groups are actively

  3. Comprehensive imaging of tumor recurrence in breast cancer patients using whole-body MRI at 1.5 and 3 T compared to FDG-PET-CT

    Energy Technology Data Exchange (ETDEWEB)

    Schmidt, Gerwin P. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany)], E-mail: gerwin.schmidt@med.uni-muenchen.de; Baur-Melnyk, Andrea [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Haug, Alexander [Department of Nuclear Medicine, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Heinemann, Volker [Department of Internal Medicine III, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Bauerfeind, Ingo [Department of Obstetrics and Gynecology, University Hospitals Munich-Grosshadern, 81377 Munich (Germany); Reiser, Maximilian F. [Institute of Clinical Radiology, University Hospitals Munich-Grosshadern, Marchioninistr. 15, 81377 Munich (Germany); Schoenberg, Stefan O. [Institute of Clinical Radiology University Hospital Mannheim, Medical Faculty Mannheim, University of Heidelberg (Germany)

    2008-01-15

    Purpose: To compare the diagnostic accuracy for the detection of tumor recurrence in breast cancer patients using whole-body-MRI (WB-MRI) at 1.5 or 3 T compared to FDG-PET-CT. Materials and methods: Thirty-three female patients with breast cancer and suspicion of recurrence underwent FDG-PET-CT and WB-MRI. Coronal T1w-TSE- and STIR-sequences, HASTE-imaging of the lungs, contrast-enhanced T1w- and T2w-TSE-sequences of the liver, brain and abdomen were performed, using a WB-MRI-scanner at 1.5 (n = 23) or 3 T (n = 10). Presence of local recurrence, lymph node involvement and distant metastatic disease was assessed using clinical and radiological follow-up as a standard of reference. Results: Tumor recurrence was found in 20 of 33 patients. Overall 186 malignant foci were detected with WB-MRI and PET-CT. Both modalities revealed two recurrent tumors of the breast. PET-CT detected more lymph node metastases (n = 21) than WB-MRI (n = 16). WB-MRI was more precise in the detection of distant metastases (n = 154 versus n = 147). Sensitivity was 93% (172/186) and 91% (170/186) for WB-MRI and PET-CT, specificity was 86% (66/77) and 90% (69/77), respectively. Examination times for WB-MRI at 1.5 and 3 T were 51 and 43 min, respectively, examination time for PET-CT was 103 min. Conclusion: WB-MRI and PET-CT are useful for the detection of tumor recurrence in the follow-up of breast cancer. WB-MRI is highly sensitive to distant metastatic disease. PET-CT is more sensitive in detecting lymph node involvement. Tumor screening with WB-MRI is feasible at 1.5 and 3 T, scan time is further reduced at 3 T with identical resolution.

  4. Value of coincidence gamma camera PET for diagnosing head and neck tumors: functional imaging and image coregistration

    International Nuclear Information System (INIS)

    Dresel, S.; Brinkbaeumer, K.; Schmid, R.; Hahn, K.

    2001-01-01

    54 patients suffering from head and neck tumors (30 m, 24 f, age: 32-67 years) were examined using dedicated PET and coincidence gamma camera PET after injection of 185-350 MBq [ 18 F]FDG. Examinations were carried out on the dedicated PET first (Siemens ECAT Exact HR+) followed by a scan on the coincidence gamma camera PET (Picker Prism 2000 XP-PCD, Marconi Axis g-PET 2 AZ). Dedicated PET was acquired in 3D mode, coincidence gamma camera PET was performed in list mode using an axial filter. Reconstruction of data was performed iteratively on both, dedicated PET and coincidence gamma camera PET. All patients received a CT scan in multislice technique (Siemens Somatom Plus 4, Marconi MX 8000). Image coregistration was performed on an Odyssey workstation (Marconi). All findings have been verified by the gold standard histology or in case of negative histology by follow-up. Results: Using dedicated PET the primary or recurrent lesion was correctly diagnosed in 47/48 patients, using coincidence gamma camera PET in 46/48 patients and using CT in 25/48 patients. Metastatic disease in cervical lymph nodes was diagnosed in 17/18 patients with dedicated PET, in 16/18 patients with coincidence gamma camera PET and in 15/18 with CT. False-positive results with regard to lymph node metastasis were seen with one patient for dedicated PET and hybrid PET, respectively, and with 18 patients for CT. In a total of 11 patients unknown metastatic lesions were seen with dedicated PET and with coincidence gamma camera PET elsewhere in the body (lung: n = 7, bone: n = 3, liver: n = 1). Additional malignant disease other than the head and neck tumor was found in 4 patients. (orig.) [de

  5. Experience with PET FDG - Preliminary analysis

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6±18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477±107 MBq (12.9±2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94±17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9 patients

  6. Experience with PET FDG - Preliminary analysis

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Galaz, Rodrigo; Miranda, Karina [Centro PET de Imagenes Moleculares, Hospital Militar de Santiago, Santiago (Chile)

    2004-01-01

    Full text: The objective of this preliminary communication was to analyse the indications and data in initial group of patients studied with first dedicated PET scanner in the country at Hospital Militar in Santiago Chile. The main application of positron emission tomography (PET) with 18-Fluoro deoxyglucose (FDG) is related with oncological patients management. We studied 136 patients, 131 (97%) with known or suspected malignant disease and remaining 5 for cardiological or neuropsychiatric disease. Ten patients were controlled diabetics (1 insulin dependent). Their mean age was 51.6{+-}18 years ranging from 6 to 84 years and 65% were females. A total of 177 scans were acquired using a dedicated PET (Siemens HR + with 4mm resolution) system. Mean F18-FDG injected dose was 477{+-}107 MBq (12.9{+-}2.9 mCi). Mean blood glucose levels, performed prior the injection, were 94{+-}17mg/dl (range 62-161). F18-FDG was obtained from the cyclotron IBA Cyclone 18/9 installed in the Chilean Agency of Nuclear Energy, distant about 15 miles away from the clinical PET facility. PET studies were analyzed by at least 4 independent observers visually. Standardized uptake value (SUV) was calculated in some cases. Image fusion of FDG images with recent anatomical (CT, MRI) studies was performed where available. Data acquisition protocol consisted in 7-8 beds/study from head to mid-thighs, with 6-7-min/bed acquisitions, 36% transmission with germanium 68 rods. Data was reconstructed with standard OSEM protocol. The main indications included pulmonary lesions in 31%, gastrointestinal cancers in 21%, melanoma in 13% and lymphoma in 9% patients. The remaining were of breast, thyroid, testes, ovary, musculoskeletal (soft tissue and bone), brain tumour etc. Abnormal focal tracer uptake was observed in 83/131 oncological patients, 54% corroborating with clinical diagnosis of primary tumor or recurrence while 46% showed new metastatic localization. FDG scans were normal 36/131 patients. In 9

  7. Optimized production, quality control, biological evaluation and PET/CT imaging of {sup 68}Ga-PSMA-617 in breast adenocarcinoma model

    Energy Technology Data Exchange (ETDEWEB)

    Sharifi, Mehdi; Yousefnia, Hassan; Bahrami-Samani, Ali; Zolghadri, Samaneh; Alirezapour, Behrouz [Nuclear Science and Technology Research Institute (NSTRI), Tehran (Iran, Islamic Republic of); Jalilian, Amir Reza; Geramifa, Parham; Beiki, Davood [Tehran Univ. of Medical Sciences (Iran, Islamic Republic of). Research Center for Nuclear Medicine; Maus, Stephan [Univ. Medical Centre Mainz (Germany). Clinic of Nuclear Medicine

    2017-08-01

    Optimized production, quality control and preclinical evaluation of {sup 68}Ga-PSMA-617 as a PET radiotracer for PSMA-positive malignancies as well as successful application in imaging of breast adenocarcinomas are reported. {sup 68}Ga-PSMA-617 radiolabeling and QC optimization, stability, log P, biodistribution in breast adenocarcinomas-bearing mice (direct and blockade studies) and also PET/CT imaging was performed. {sup 68}Ga-PSMA-617 complex was prepared in high radiochemical purity (>96%, ITLC, HPLC) and specific activity of 300-310 GBq/mM at 95 C using 2-4 micrograms of the peptide in 10 min followed by solid phase purification. The tracer was stable in serum and final formulation for at least 120 min. The log P was -1.98. Western blot test on the tumor cell homogenates demonstrated distinct existence of the PSMA on the surface. The biodistribution of the tracer demonstrated specific kidney and tumor significant uptake using blocking study. Significant tumor:blood and tumor:muscle ratio uptake observed at 30 min post-injection (2.69 and 19.1, respectively). A reduction of 40-80% off tumor uptake in the study time period observed using blocking test. {sup 68}Ga-PSMA-617 can be proposing a possible tracer for PET imaging of breast adenocarcinomas and other breast malignancies.

  8. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    International Nuclear Information System (INIS)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G.; Arlinghaus, Lori R.; Lee, Tzu-Cheng; MacDonald, Lawrence R.; Partridge, Savannah C.; Kang, Hakmook; Linden, Hannah M.; Kinahan, Paul E.; Yankeelov, Thomas E.

    2015-01-01

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [ 18 F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV peak and SUV max , respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV peak and SUV max from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV peak and SUV max were significantly lower than supine in both

  9. The Assessment of Estrogen Receptor Status and Its Intratumoral Heterogeneity in Patients With Breast Cancer by Using 18F-Fluoroestradiol PET/CT.

    Science.gov (United States)

    Yang, Zhongyi; Sun, Yifei; Xu, Xiaoping; Zhang, Yongping; Zhang, Jianping; Xue, Jing; Wang, Mingwei; Yuan, Huiyu; Hu, Silong; Shi, Wei; Zhu, Beiling; Zhang, Yingjian

    2017-06-01

    The aim of this study was to investigate the clinical value of F-fluoroestradiol (F-FES) PET/CT in the assessment of the estrogen receptor (ER) and its intratumoral heterogeneity in breast cancer patients. Forty-six female patients (50 lesions) with histologically confirmed invasive breast cancer who underwent both F-FES and F-FDG PET/CT in our center were retrospectively included. All the patients enrolled were scheduled to undergo biopsy. The F-FES and FDG uptakes were compared with pathological features (tumor size, ER, progesterone receptor, human epidermal growth factor receptor 2, and Ki67%). The optimal threshold to discriminate ER-positive and ER-negative lesions was determined by receiver operating characteristic curve analysis. Furthermore, we observed the intratumoral heterogeneity by a heterogeneity index (SUVmax/SUVmean) and compared the results with the Chang-Gung Image Texture Analysis. There was good agreement between F-FES uptake and ER, progesterone receptor, and human epidermal growth factor receptor 2 expression (P heterogeneity index-FES can easily observe ER heterogeneity. In addition, our results suggested that recurrent/metastatic patients and lesions located other than breast might have greater heterogeneity. F-FES PET/CT is a feasible, noninvasive method for assessing ER expression in breast cancer patients. Because intratumoral heterogeneity exists, F-FES PET/CT might better reflect the ER expression, especially in metastatic patients after treatment, thus assisting in making individualized treatment decisions.

  10. Predictive and prognostic value of FDG-PET/CT imaging and different response evaluation criteria after primary systemic therapy of breast cancer.

    Science.gov (United States)

    Tőkés, Tímea; Kajáry, Kornélia; Szentmártoni, Gyöngyvér; Lengyel, Zsolt; Györke, Tamás; Torgyík, László; Somlai, Krisztián; Tőkés, Anna-Mária; Kulka, Janina; Dank, Magdolna

    2017-01-01

    (1) To predict pathological complete remission (pCR) and survival after primary systemic therapy (PST) in patients diagnosed with breast cancer by using two different PET/CT based scores: a simplified PERCIST-based PET/CT score (Method 1) and a combined PET/CT score supplemented with the morphological results of the RECIST system (Method 2) and (2) to assess the effect of different breast carcinoma subtypes on tumor response and its evaluation. Eighty-eight patients were enrolled in the study who underwent PET/CT imaging before and after PST. PET/CTs were evaluated by changes in maximum Standardized Uptake Value (SUVmax) and tumor size. Method 1 and 2 were applied to predict pathological complete remission (pCR). Kaplan-Meier analyses for survival were performed. Classification into biological subtypes was performed based on the pre-therapeutic tumor characteristics. A total of 30/88 patients showed pCR (34.1 %). Comparing pCR/non-pCR patient groups, significant differences were detected by changes in SUVmax (p evaluation with Method 2 and not with Method 1. In our study, neither clinical nor pathological CR were predictors of longer progression-free survival. Our results suggest that combined PET/CT criteria are more predictive of pCR. The effect of biological subtypes is significant on pCR rate as well as on the changes in FDG-uptake and morphological tumor response. Response evaluation with combined criteria was also able to reflect the differences between the biological behavior of breast tumor subtypes.

  11. Performance Evaluation of a Dedicated Preclinical PET/CT System for the Assessment of Mineralization Process in a Mouse Model of Atherosclerosis.

    Science.gov (United States)

    Rucher, Guillaume; Cameliere, Lucie; Fendri, Jihene; Abbas, Ahmed; Dupont, Kevin; Kamel, Said; Delcroix, Nicolas; Dupont, Axel; Berger, Ludovic; Manrique, Alain

    2018-04-30

    The purpose of this study was to assess the impact of positron emission tomography/X-ray computed tomography (PET/CT) acquisition and reconstruction parameters on the assessment of mineralization process in a mouse model of atherosclerosis. All experiments were performed on a dedicated preclinical PET/CT system. CT was evaluated using five acquisition configurations using both a tungsten wire phantom for in-plane resolution assessment and a bar pattern phantom for cross-plane resolution. Furthermore, the radiation dose of these acquisition configurations was calculated. The PET system was assessed using longitudinal line sources to determine the optimal reconstruction parameters by measuring central resolution and its coefficient of variation. An in vivo PET study was performed using uremic ApoE -/- , non-uremic ApoE -/- , and control mice to evaluate optimal PET reconstruction parameters for the detection of sodium [ 18 F]fluoride (Na[ 18 F]F) aortic uptake and for quantitative measurement of Na[ 18 F]F bone influx (Ki) with a Patlak analysis. For CT, the use of 1 × 1 and 2 × 2 binning detector mode increased both in-plane and cross-plane resolution. However, resolution improvement (163 to 62 μm for in-plane resolution) was associated with an important radiation dose increase (1.67 to 32.78 Gy). With PET, 3D-ordered subset expectation maximization (3D-OSEM) algorithm increased the central resolution compared to filtered back projection (1.42 ± 0.35 mm vs. 1.91 ± 0.08, p PET resolution for preclinical study (FWHM = 0.98 mm). These PET reconstruction parameters allowed the detection of Na[ 18 F]F aortic uptake in 3/14 ApoE -/- mice and demonstrated a decreased Ki in uremic ApoE -/- compared to non-uremic ApoE -/- and control mice (p PET. In addition, improving the CT resolution was associated with a dramatic radiation dose increase.

  12. A study of the changes of breast uptake in menstrual cycle on {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, Hoon Hee; Tak, Yeo Jin [Dept. of Radiological Technology, Shingu College, Sungnam (Korea, Republic of); Park, Min Soo [Dept. of Nuclear Medicine, Severance Hospital, Yonsei University Health System, Seoul (Korea, Republic of); Lee, Ju Young [Graduate School of Public Health, Yonsei University, Seoul (Korea, Republic of)

    2015-04-15

    {sup 18}F-FDG PET/CT has been known a useful modality to diagnose high-glucose-using cells such as cancer cells by glucose metabolism of FDG. Mainly, FDG takes on cancer and inflammatory cells; however, there have been FDG uptakes on normal tissues by individual physiological characteristics, occasionally. Especially, in fertile females, unusual FDG uptake of breast changes as the menstrual cycle, and disturb diagnosis. Therefore, the study aimed to evaluate the change of breast FDG uptake in menstrual cycle on {sup 18}F-FDG PET/CT. 160 females (34±3.5 years old) who do not undergo a gynecologic anamnesis and have regular menstrual cycle over the previous 6 months were examined. They were divided 4 groups (each 40 patients) as flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator 0.14. and history taking. Discovery Ste (GE Healthcare, Milwaukee, Mi, USA) was used a s PET/CT. We analyzed SUVs on a ccumulated r egion on b reast, and 3 nuclear medicine specialists did the Blind test. SUVs on the Breast were flow phase (1.64±0.25), proliferative phase (0.93±0.28), ovulatory phase (1.66±0.26) and secretory phase (1.77±0.28). It showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In gross analysis, the accumulation of breast was divided into 3 grades as comparing with lung and liver. The breast’s uptake was equal to lung (Grade Ⅰ); between lung and liver (Grade II); equal to or greater than liver (Grade III). The results showed high uptake value in secretory, flow phase and ovulatory phase (p<0.05). In fertile females, FDG uptake of breast changed as menstrual cycle, and it available to diagnose breast disease. Therefore, we consider reducing false-negative finding of breast disease, by doing examination on appropriate period through history taking about individual menstrual cycle.

  13. PET/SPECT/CT multimodal imaging in a transgenic mouse model of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Boisgard, R.; Alberini, J.L.; Jego, B.; Siquier, K.; Theze, B.; Guillermet, S.; Tavitian, B. [Service Hospitalier Frederic Joliot, Institut d' Imagerie BioMedicale, CEA, 91 - Orsay (France); Inserm, U803, 91 - Orsay (France)

    2008-02-15

    Background. - In the therapy monitoring of breast cancer, conventional imaging methods include ultrasound, mammography, CT and MRI, which are essentially based on tumor size modifications. However these modifications represent a late consequence of the biological response and fail to differentiate scar or necrotic tissue from residual viable tumoral tissue. Therefore, a current objective is to develop tools able to predict early response to treatment. Positron Emission Tomography (PET) and Single Photon Emission Computerized Tomography (SPECT) are imaging modalities able to provide extremely sensitive quantitative molecular data and are widely used in humans and animals. Results. - Mammary epithelial cells of female transgenic mice expressing the polyoma middle T onco-protein (Py M.T.), undergo four distinct stages of tumour progression, from pre malignant to malignant stages. Stages are identifiable in the mammary tissue and can lead to the development of distant metastases Longitudinal studies by dynamic whole body acquisitions by multimodal imaging including PET, SPECT and Computed Tomography (CT) allow following the tumoral evolution in Py M.T. mice in comparison with the histopathological analysis. At four weeks of age, mammary hyperplasia was identified by histopathology, but no abnormalities were found by palpation or detected by PET with 2-deoxy-2-[{sup 18}F]fluoro-D-glucose. Such as in some human mammary cancers, the sodium iodide sym-porter (N.I.S.) in tumoral mammary epithelial cells is expressed in this mouse model. In order to investigate the expression of N.I.S. in the Py M.T. mice mammary tumours, [{sup 99m}Tc]TcO{sub 4} imaging was performed with a dedicated SPECT/CT system camera (B.I.O.S.P.A.C.E. Gamma Imager/CT). Local uptake of [{sup 99m}Tc]TcO{sub 4} was detected as early as four weeks of age. The efficacy of chemotherapy was evaluated in this mouse model using a conventional regimen (Doxorubicine, 100 mg/ kg) administered weekly from nine to

  14. Comparison of FDG-PET/CT and contrast-enhanced CT for monitoring therapy response in patients with metastatic breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Riedl, Christopher C.; Ulaner, Gary A.; Jochelson, Maxine S.; Weber, Wolfgang A. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Weill Cornell Medical College, Department of Radiology, New York, NY (United States); Pinker, Katja [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); Ong, Leonard T. [Memorial Sloan Kettering Cancer Center, Department of Radiology, New York, NY (United States); Baltzer, Pascal [Medical University of Vienna, Department of Biomedical Imaging and Image-guided Therapy, Vienna (Austria); McArthur, Heather L. [Cedars-Sinai Medical Center, Department of Medicine, Breast Oncology, Los Angeles, CA (United States); Goenen, Mithat [Memorial Sloan Kettering Cancer Center, Department of Epidemiology and Biostatistics, New York, NY (United States); Dickler, Maura [Memorial Sloan Kettering Cancer Center, Department of Medicine, New York, NY (United States)

    2017-08-15

    The aim of this study was to compare fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT) and contrast-enhanced computed tomography (CE-CT) for the prediction of progression-free survival (PFS) and disease-specific survival (DSS) in patients with stage IV breast cancer undergoing systemic therapy. Sixty-five patients with metastatic breast cancer treated with first- or second-line systemic therapy in prospective clinical trials were included. Response to treatment was evaluated by Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 for CE-CT and by PET Response Criteria in Solid Tumors (PERCIST), respectively. All responders by RECIST (n = 22) were also responders by PERCIST, but 40% (17/43) of non-responders by RECIST were responders by PERCIST. Responses according to RECIST and PERCIST both correlated with PFS, but PERCIST showed a significantly higher predictive accuracy (concordance index for PFS: 0.70 vs. 0.60). One-year PFS for responders vs. non-responders by RECIST was 59% vs. 27%, compared to 63% vs. 0% by PERCIST. Four-year DSS of responders and non-responders by RECIST was 50% and 38%, respectively (p = 0.2, concordance index: 0.55) as compared to 58% vs. 18% for PERCIST (p < 0.001, concordance index: 0.65). Response on PET/CT was also a significantly better predictor for DSS than disease control on CE-CT. In patients with metastatic breast cancer, tumor response on PET/CT appears to be a superior predictor of PFS and DSS than response on CE-CT. Monitoring tumor response by PET/CT may increase the power of clinical trials using tumor response as an endpoint, and may improve patient management in clinical routine. (orig.)

  15. Evaluation of therapy response in breast and ovarian cancer patients by positron emission tomography (PET)

    Energy Technology Data Exchange (ETDEWEB)

    Baum, R. P.; Przetak, C. [Zentralklinik Bad Berka, Clinic of Nuclear Medicine, Center for PET, Bad Berka (Germany)

    2001-09-01

    Positron emission tomography (PET) has the potential to contribute significantly to treatment planning and to the evaluation of response to therapy in patients with cancer. For disease recurrence PET imaging provides information non-invasively. The final goal is to biologically characterize an individual patients' tumor and to predict the response to treatment at the earliest possible time. Quantitative and/or semi-quantitative PET studies yield valuable information in breast cancer regarding prognosis and response to chemohormontherapy in a timely fashion. In ovarian cancer, up to now only few studies have been performed applying PET techniques for the evaluation of treatment response. These preliminary studies indicate that serial assessment of tumor metabolism by FDG-PET early during effective chemotherapy may predict subsequent response to such therapy. PET studies can be repeated without any side-effects and with low radiation exposure and results can be directly correlated with clinical laboratory data and histology. Therapy monitoring by PET could help to optimize neoadjuvant therapy protocols and to avoid ineffective preoperative therapy in non-responders, but this has to be proven in a larger number of patients and in different neoadjuvant settings such as chemotherapy, radiation therapy, hormone therapy or a combination of these.

  16. Evaluation of therapy response in breast and ovarian cancer patients by positron emission tomography (PET)

    International Nuclear Information System (INIS)

    Baum, R. P.; Przetak, C.

    2001-01-01

    Positron emission tomography (PET) has the potential to contribute significantly to treatment planning and to the evaluation of response to therapy in patients with cancer. For disease recurrence PET imaging provides information non-invasively. The final goal is to biologically characterize an individual patients' tumor and to predict the response to treatment at the earliest possible time. Quantitative and/or semi-quantitative PET studies yield valuable information in breast cancer regarding prognosis and response to chemohormontherapy in a timely fashion. In ovarian cancer, up to now only few studies have been performed applying PET techniques for the evaluation of treatment response. These preliminary studies indicate that serial assessment of tumor metabolism by FDG-PET early during effective chemotherapy may predict subsequent response to such therapy. PET studies can be repeated without any side-effects and with low radiation exposure and results can be directly correlated with clinical laboratory data and histology. Therapy monitoring by PET could help to optimize neoadjuvant therapy protocols and to avoid ineffective preoperative therapy in non-responders, but this has to be proven in a larger number of patients and in different neoadjuvant settings such as chemotherapy, radiation therapy, hormone therapy or a combination of these

  17. Solitary Plasmacytoma of the Sternum Mimicking Bone Metastasis in a Patient with a History of Breast Cancer Evaluated by F-18-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Treglia, Giorgio; Luca, Giovanella [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Barbara, Muoio; Carmelo, Caldarella [Catholic Univ., Rome (Italy)

    2014-06-15

    A 65-year-old woman with a history of breast cancer (stage T2N0M0 treated with left breast conservative therapy 7 years previously followed by hormone therapy) underwent fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (F-18-FDG PET/CT) for restaging due to increased serum tumour markers levels (CA15-3, 37 U/ml and CEA, 8 ng/ml). The patient presented thoracic pain before performing F-18-FDG PET/CT. PET/CT demonstrated an area of increased F-18-FDG uptake corresponding to an osteolytic lesion occupying the upper sternum suspicious for bone metastasis. No other areas of abnormal F-18-FDG uptake were detected in the rest of the body. Based on this PET/CT finding, the patient performed biopsy of the sternal lesion. Histology demonstrated the presence of a sternal plasmacytoma and the patient was addressed to radiation therapy. The role of F-18-FDG PET/CT in patients with multiple myeloma is well known, whereas only some articles evaluated the usefulness of this method in patients with solitary plasmacytomas. In particular, F-18-FDG PET/CT may be useful in demonstrating the evolution of solitary plasmacytomas in multiple myeloma. In our case F-18-FDG PET/CT was useful in detecting a solitary plasmacytoma of the sternum mimicking bone metastasis in a patient with history of breast cancer, correctly addressing to further histological evaluation.

  18. Solitary Plasmacytoma of the Sternum Mimicking Bone Metastasis in a Patient with a History of Breast Cancer Evaluated by F-18-FDG PET/CT

    International Nuclear Information System (INIS)

    Treglia, Giorgio; Luca, Giovanella; Barbara, Muoio; Carmelo, Caldarella

    2014-01-01

    A 65-year-old woman with a history of breast cancer (stage T2N0M0 treated with left breast conservative therapy 7 years previously followed by hormone therapy) underwent fluorine-18-fluorodeoxyglucose positron emission tomography/computed tomography (F-18-FDG PET/CT) for restaging due to increased serum tumour markers levels (CA15-3, 37 U/ml and CEA, 8 ng/ml). The patient presented thoracic pain before performing F-18-FDG PET/CT. PET/CT demonstrated an area of increased F-18-FDG uptake corresponding to an osteolytic lesion occupying the upper sternum suspicious for bone metastasis. No other areas of abnormal F-18-FDG uptake were detected in the rest of the body. Based on this PET/CT finding, the patient performed biopsy of the sternal lesion. Histology demonstrated the presence of a sternal plasmacytoma and the patient was addressed to radiation therapy. The role of F-18-FDG PET/CT in patients with multiple myeloma is well known, whereas only some articles evaluated the usefulness of this method in patients with solitary plasmacytomas. In particular, F-18-FDG PET/CT may be useful in demonstrating the evolution of solitary plasmacytomas in multiple myeloma. In our case F-18-FDG PET/CT was useful in detecting a solitary plasmacytoma of the sternum mimicking bone metastasis in a patient with history of breast cancer, correctly addressing to further histological evaluation

  19. Neoadjuvant chemotherapy in breast cancer: prediction of pathologic response with PET/CT and dynamic contrast-enhanced MR imaging--prospective assessment.

    Science.gov (United States)

    Tateishi, Ukihide; Miyake, Mototaka; Nagaoka, Tomoaki; Terauchi, Takashi; Kubota, Kazunori; Kinoshita, Takayuki; Daisaki, Hiromitsu; Macapinlac, Homer A

    2012-04-01

    To clarify whether fluorine 18 ((18)F) fluorodeoxyglucose (FDG) positron emission tomography (PET)/computed tomography (CT) and dynamic contrast-enhanced (DCE) magnetic resonance (MR) imaging performed after two cycles of neoadjuvant chemotherapy (NAC) can be used to predict pathologic response in breast cancer. Institutional human research committee approval and written informed consent were obtained. Accuracy after two cycles of NAC for predicting pathologic complete response (pCR) was examined in 142 women (mean age, 57 years: range, 43-72 years) with histologically proved breast cancer between December 2005 and February 2009. Quantitative PET/CT and DCE MR imaging were performed at baseline and after two cycles of NAC. Parameters of PET/CT and of blood flow and microvascular permeability at DCE MR were compared with pathologic response. Patients were also evaluated after NAC by using Response Evaluation Criteria in Solid Tumors (RECIST) 1.1 based on DCE MR measurements and European Organization for Research and Treatment of Cancer (EORTC) criteria and PET Response Criteria in Solid Tumors (PERCIST) 1.0 based on PET/CT measurements. Multiple logistic regression analyses were performed to examine continuous variables at PET/CT and DCE MR to predict pCR, and diagnostic accuracies were compared with the McNemar test. Significant decrease from baseline of all parameters at PET/CT and DCE MR was observed after NAC. Therapeutic response was obtained in 24 patients (17%) with pCR and 118 (83%) without pCR. Sensitivity, specificity, and accuracy to predict pCR were 45.5%, 85.5%, and 82.4%, respectively, with RECIST and 70.4%, 95.7%, and 90.8%, respectively, with EORTC and PERCIST. Multiple logistic regression revealed three significant independent predictors of pCR: percentage maximum standardized uptake value (%SUV(max)) (odds ratio [OR], 1.22; 95% confidence interval [CI]: 1.11, 1.34; P PET/CT is superior to DCE MR for the prediction of pCR (%SUV(max) [90.1%] vs %κ

  20. Clinicopathological and prognostic relevance of uptake level using 18F-fluorodeoxyglucose positron emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in primary breast cancer

    International Nuclear Information System (INIS)

    Ueda, Shigeto; Tsuda, Hitoshi; Asakawa, Hideki

    2008-01-01

    Using integrated 18 F-fluorodeoxyglucose positron emission tomography/computed tomography fusion imaging ( 18 F-FDG PET/CT), the clinical significance of 18 F-FDG uptake was evaluated in patients with primary breast cancer. Clinicopathological correlation with the level of maximum standardized uptake values (SUV) 60 min obtained from preoperative 18 F-FDG PET/CT were examined in 152 patients with primary breast cancer. The prognostic impact of the level of SUV was explored using simulated prognosis derived from computed program Adjuvant! in 136 (89%) patients with invasive ductal carcinoma (IDC). High SUV level was significantly correlated with tumor invasive size (≤2 cm) (P 18 F-FDG would be predictive of poor prognosis in patients with primary breast cancer, and aggressive features of cancer cells in patients with early breast cancer. 18 F-FDG PET/CT could be a useful tool to pretherapeutically predict biological characteristics and baseline risk of breast cancer. (author)

  1. [18F]Fluorodeoxyglucose (FDG)-Positron Emission Tomography (PET)/Computed Tomography (CT) in Suspected Recurrent Breast Cancer: A Prospective Comparative Study of Dual-Time-Point FDG-PET/CT, Contrast-Enhanced CT, and Bone Scintigraphy.

    Science.gov (United States)

    Hildebrandt, Malene Grubbe; Gerke, Oke; Baun, Christina; Falch, Kirsten; Hansen, Jeanette Ansholm; Farahani, Ziba Ahangarani; Petersen, Henrik; Larsen, Lisbet Brønsro; Duvnjak, Sandra; Buskevica, Inguna; Bektas, Selma; Søe, Katrine; Jylling, Anne Marie Bak; Ewertz, Marianne; Alavi, Abass; Høilund-Carlsen, Poul Flemming

    2016-06-01

    To prospectively investigate the diagnostic accuracy of [(18)F]fluorodeoxyglucose (FDG)-positron emission tomography (PET)/computed tomography (CT) with dual-time-point imaging, contrast-enhanced CT (ceCT), and bone scintigraphy (BS) in patients with suspected breast cancer recurrence. One hundred women with suspected recurrence of breast cancer underwent 1-hour and 3-hour FDG-PET/CT, ceCT, and BS within approximately 10 days. The study was powered to estimate the precision of the individual imaging tests. Images were visually interpreted using a four-point assessment scale, and readers were blinded to other test results. The reference standard was biopsy along with treatment decisions and clinical follow-up (median, 17 months). FDG-PET/CT resulted in no false negatives and fewer false positives than the other imaging techniques. Accuracy of results were similar for 1-hour and 3-hour FDG-PET/CT. For distant recurrence, the area under the receiver operating curve was 0.99 (95% CI, 0.97 to 1) for FDG-PET/CT, 0.84 (95% CI, 0.73 to 0.94) for ceCT, and 0.86 (95% CI, 0.77 to 0.94) for the combined ceCT+BS. Of 100 patients, 22 (22%) were verified with distant recurrence, and 18 of these had bone involvement. Nineteen patients (19%) had local recurrence only. In exploratory analyses, diagnostic accuracy of FDG-PET/CT was better than ceCT alone or ceCT combined with BS in diagnosing distant, bone, and local recurrence, shown by a greater area under the receiver operating curve and higher sensitivity, specificity, and superior likelihood ratios. FDG-PET/CT was accurate in diagnosing recurrence in breast cancer patients. It allowed for distant recurrence to be correctly ruled out and resulted in only a small number of false-positive cases. Exploratory findings suggest that FDG-PET/CT has greater accuracy than conventional imaging technologies in this patient group. © 2016 by American Society of Clinical Oncology.

  2. Comparison of prone versus supine 18F-FDG-PET of locally advanced breast cancer: Phantom and preliminary clinical studies

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jason M.; Rani, Sudheer D.; Li, Xia; Whisenant, Jennifer G.; Abramson, Richard G. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Arlinghaus, Lori R. [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Lee, Tzu-Cheng [Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); MacDonald, Lawrence R.; Partridge, Savannah C. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Kang, Hakmook [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 and Department of Biostatistics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Linden, Hannah M. [Department of Medical Oncology, University of Washington, Seattle, Washington 98195 (United States); Kinahan, Paul E. [Department of Radiology, University of Washington, Seattle, Washington 98195 (United States); Department of Bioengineering, University of Washington, Seattle, Washington 98195 (United States); Department of Physics, University of Washington, Seattle, Washington 98195 (United States); Department of Electrical Engineering, University of Washington, Seattle, Washington 98195 (United States); Yankeelov, Thomas E., E-mail: thomas.yankeelov@vanderbilt.edu [Institute of Imaging Science, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Radiology and Radiological Sciences, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Biomedical Engineering, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Physics, Vanderbilt University, Nashville, Tennessee 37232 (United States); Department of Cancer Biology, Vanderbilt University, Nashville, Tennessee 37232 (United States)

    2015-07-15

    Purpose: Previous studies have demonstrated how imaging of the breast with patients lying prone using a supportive positioning device markedly facilitates longitudinal and/or multimodal image registration. In this contribution, the authors’ primary objective was to determine if there are differences in the standardized uptake value (SUV) derived from [{sup 18}F]fluorodeoxyglucose (18F-FDG) positron emission tomography (PET) in breast tumors imaged in the standard supine position and in the prone position using a specialized positioning device. Methods: A custom positioning device was constructed to allow for breast scanning in the prone position. Rigid and nonrigid phantom studies evaluated differences in prone and supine PET. Clinical studies comprised 18F-FDG-PET of 34 patients with locally advanced breast cancer imaged in the prone position (with the custom support) followed by imaging in the supine position (without the support). Mean and maximum values (SUV{sub peak} and SUV{sub max}, respectively) were obtained from tumor regions-of-interest for both positions. Prone and supine SUV were linearly corrected to account for the differences in 18F-FDG uptake time. Correlation, Bland–Altman, and nonparametric analyses were performed on uptake time-corrected and uncorrected data. Results: SUV from the rigid PET breast phantom imaged in the prone position with the support device was 1.9% lower than without the support device. In the nonrigid PET breast phantom, prone SUV with the support device was 5.0% lower than supine SUV without the support device. In patients, the median (range) difference in uptake time between prone and supine scans was 16.4 min (13.4–30.9 min), which was significantly—but not completely—reduced by the linear correction method. SUV{sub peak} and SUV{sub max} from prone versus supine scans were highly correlated, with concordance correlation coefficients of 0.91 and 0.90, respectively. Prone SUV{sub peak} and SUV{sub max} were

  3. [18F]fluorodeoxyglucose PET/computed tomography in breast cancer and gynecologic cancers

    DEFF Research Database (Denmark)

    Hildebrandt, Malene Grubbe; Kodahl, Annette Raskov; Teilmann-Jørgensen, Dorte

    2015-01-01

    In this literature review, an update is provided on the role of [(18)F]fluorodeoxyglucose PET/computed tomography in different clinical settings of the 4 most frequent female-specific cancer types: breast, endometrial, ovarian, and cervical cancer. The most recent knowledge regarding primary...... diagnosis, staging, response evaluation, prognostic and predictive values, recurrence detection, and radiotherapy planning is evaluated, including, when clinically relevant, considerations with respect to the epidemiology, treatment, and course of the diseases....

  4. Metastatic Brachial Plexopathy in a Case of Recurrent Breast Carcinoma Demonstrated on {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Tripathi, Madhavi; Das, Chandan J.; Srivastava, Anurag; Bal, ChandraSekhar; Malhotra, Arun [All India Institute of Medical Sciences, New Delhi (India)

    2014-03-15

    This case highlights the importance of recognition of the pattern of metastatic brachialplexopathy in breast cancer patients undergoing {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) positron emission tomography/computed tomography (PET/CT) for evaluation of recurrent disease.This pattern can be appreciated on maximum intensity projection (MIP) and coronal {sup 18}F-FDG PET/CT images as a linear extension of tracer activity from superomedial aspect(supra/infraclavicular) to lateral aspect of the axilla closely related to the subclavian/axillary vessels). A 35-year-old woman diagnosed with infiltrating ductal carcinoma of the right breast had undergone six cycles of neoadjuvant chemotherapy, followed by wide local incision and radiotherapy. She had local recurrence, for which she was operated upon and given chemotherapy. She presented to her oncologist with pain and swelling in the right breast, nodules in the right axilla and restriction of movement of the right upper limb. The patient was referred for {sup 18}F-FDG PET/CT to evaluate the extent of recurrent/metastatic disease. Whole-body PET/CT was acquired 1 h following the intravenous injection of 296 MBq of {sup 18}F-FDG on a Biograph mCT scanner (Siemens). Evaluation of the MIP image revealed abnormal FDG accumulation at multiple sites in the thorax, along with a linear pattern of FDG uptake in the right lateral aspect of the upper chest (Fig. 1a, arrow). The coronal fused PET/CT image revealed a linear pattern of FDG uptake corresponding to an ill-defined mass extending from just behind the right clavicle into the right axilla (arrow). In addition, abnormal FDG accumulation was seen in a soft tissue density mass in the upper outer quadrant of the right breast, skin of the right breast laterally, both pectoral muscles (discrete foci) and in a few subpectoral nodes. Soft tissue nodular opacities in both lungs showed FDG accumulation suggestive of pulmonary metastasis (Fig. 1b, thick arrow). The patient was

  5. Integrated 18F-FDG PET/MRI in breast cancer. Early prediction of response to neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Cho, Nariya; Im, Seock-Ah; Lee, Kyung-Hun; Kim, Tae-Yong; Cheon, Gi Jeong; Park, In-Ae; Kim, Young Seon; Kwon, Bo Ra; Lee, Jung Min; Suh, Hoon Young; Suh, Koung Jin

    2018-01-01

    To explore whether integrated 18 F-FDG PET/MRI can be used to predict pathological response to neoadjuvant chemotherapy (NAC) in patients with breast cancer. Between November 2014 and April 2016, 26 patients with breast cancer who had received NAC and subsequent surgery were prospectively enrolled. Each patient underwent 18 F-FDG PET/MRI examination before and after the first cycle of NAC. Qualitative MRI parameters, including morphological descriptors and the presence of peritumoral oedema were assessed. Quantitatively, PET parameters, including maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis (TLG), and MRI parameters, including washout proportion and signal enhancement ratio (SER), were measured. The performance of the imaging parameters singly and in combination in predicting a pathological incomplete response (non-pCR) was assessed. Of the 26 patients, 7 (26.9%) exhibited a pathological complete response (pCR), and 19 (73.1%) exhibited a non-pCR. No significant differences were found between the pCR and non-pCR groups in the qualitative MRI parameters. The mean percentage reductions in TLG 30% on PET and SER on MRI were significantly greater in the pCR group than in the non-pCR group (TLG 30% -64.8 ± 15.5% vs. -25.4 ± 48.7%, P = 0.005; SER -34.6 ± 19.7% vs. -8.7 ± 29.0%, P = 0.040). The area under the receiver operating characteristic curve for the percentage change in TLG 30% (0.789, 95% CI 0.614 to 0.965) was similar to that for the percentage change in SER (0.789, 95% CI 0.552 to 1.000; P = 1.000). The specificity of TLG 30% in predicting pCR was 100% (7/7) and that of SER was 71.4% (5/7). The sensitivity of TLG 30% in predicting non-pCR was 63.2% (12/19) and that of SER was 84.2% (16/19). When the combined TLG 30% and SER criterion was applied, sensitivity was 100% (19/19), and specificity was 71.4% (5/7). 18 F-FDG PET/MRI can be used to predict non-pCR after the first cycle of NAC in patients with breast cancer

  6. {sup 18}F-FDG PET/CT imaging versus dynamic contrast-enhanced CT for staging and prognosis of inflammatory breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Champion, Laurence; Edeline, Veronique; Giraudet, Anne-Laure; Wartski, Myriam [Service de Medecine Nucleaire, Saint-Cloud (France); Lerebours, Florence [Service d' Oncologie Medicale, Saint-Cloud (France); Cherel, Pascal [Institut Curie, Hopital Rene Huguenin, Service de Radiologie, Saint-Cloud (France); Bellet, Dominique [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Paris Descartes, Pharmacologie Chimique et Genetique and Imagerie, Inserm U1022 CNRS UMR 8151, Faculte des sciences pharmaceutiques et biologiques, Paris (France); Alberini, Jean-Louis [Service de Medecine Nucleaire, Saint-Cloud (France); Universite Versailles Saint-Quentin, Faculte de medecine, Saint-Quentin-en-Yvelines (France)

    2013-08-15

    Inflammatory breast cancer (IBC) is the most aggressive type of breast cancer with a poor prognosis. Locoregional staging is based on dynamic contrast-enhanced (DCE) CT or MRI. The aim of this study was to compare the performances of FDG PET/CT and DCE CT in locoregional staging of IBC and to assess their respective prognostic values. The study group comprised 50 women (median age: 51 {+-} 11 years) followed in our institution for IBC who underwent FDG PET/CT and DCE CT scans (median interval 5 {+-} 9 days). CT enhancement parameters were net maximal enhancement, net early enhancement and perfusion. The PET/CT scans showed intense FDG uptake in all primary tumours. Concordance rate between PET/CT and DCE CT for breast tumour localization was 92 %. No significant correlation was found between SUVmax and CT enhancement parameters in primary tumours (p > 0.6). PET/CT and DCE CT results were poorly correlated for skin infiltration (kappa = 0.19). Ipsilateral foci of increased axillary FDG uptake were found in 47 patients (median SUV: 7.9 {+-} 5.4), whereas enlarged axillary lymph nodes were observed on DCE CT in 43 patients. Results for axillary node involvement were fairly well correlated (kappa = 0.55). Nineteen patients (38 %) were found to be metastatic on PET/CT scan with a significant shorter progression-free survival than patients without distant lesions (p = 0.01). In the primary tumour, no statistically significant difference was observed between high and moderate tumour FDG uptake on survival, using an SUVmax cut-off of 5 (p = 0.7 and 0.9), or between high and low tumour enhancement on DCE CT (p > 0.8). FDG PET/CT imaging provided additional information concerning locoregional involvement to that provided by DCE CT on and allowed detection of distant metastases in the same whole-body procedure. Tumour FDG uptake or CT enhancement parameters were not correlated and were not found to have any prognostic value. (orig.)

  7. Lymphadenopathy by scrub typhus mimicking metastasis on FDG PET/CT in a patient with a history of breast cancer

    International Nuclear Information System (INIS)

    Lee, Jeong Won; Lee, Sang Mi; Lee, Kyu Taek; Kim, Sung Young; Han, Sun Wook; Kim, Shin Young

    2015-01-01

    We report the case of a 60-year-old woman with left-sided breast cancer who showed lymphadenopathy mimicking metastatic lesions. She underwent surveillance 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) after treatment. PET/CT demonstrated multiple lymphadenopathies with increased FDG uptake, most notably in the right axilla. She had an eschar on the right axillary area, and her serologic test was positive for anti-Orientia tsutsugamushi IgM antibody. Ten months after the treatment, follow-up FDG PET/CT and ultrasonography showed improvement in generalized lymphadenopathy

  8. Lymphadenopathy by scrub typhus mimicking metastasis on FDG PET/CT in a patient with a history of breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Won [Dept. of Nuclear Medicine, Catholic Kwandong University International St. Mary' s Hospital, Incheon (Korea, Republic of); Lee, Sang Mi; Lee, Kyu Taek; Kim, Sung Young; Han, Sun Wook; Kim, Shin Young [Sooncheonhyang University Cheonan Hospital, Cheonan (Korea, Republic of)

    2015-06-15

    We report the case of a 60-year-old woman with left-sided breast cancer who showed lymphadenopathy mimicking metastatic lesions. She underwent surveillance 18F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) after treatment. PET/CT demonstrated multiple lymphadenopathies with increased FDG uptake, most notably in the right axilla. She had an eschar on the right axillary area, and her serologic test was positive for anti-Orientia tsutsugamushi IgM antibody. Ten months after the treatment, follow-up FDG PET/CT and ultrasonography showed improvement in generalized lymphadenopathy.

  9. SU-F-I-01: Normalized Mean Glandular Dose Values for Dedicated Breast CT Using Realistic Breast-Shaped Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, Biomedical Engeering Graduate Group, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To estimate normalized mean glandular dose values for dedicated breast CT (DgN-CT) using breast CT-derived phantoms and compare to estimations using cylindrical phantoms. Methods: Segmented breast CT (bCT) volume data sets (N=219) were used to measure effective diameter profiles and were grouped into quintiles by volume. The profiles were averaged within each quintile to represent the range of breast sizes found clinically. These profiles were then used to generate five voxelized computational phantoms (V1, V2, V3, V4, V5 for the small to large phantom sizes, respectively), and loaded into the MCNP6 lattice geometry to simulate normalized mean glandular dose coefficients (DgN-CT) using the system specifications of the Doheny-prototype bCT scanner in our laboratory. The DgN-CT coefficients derived from the bCT-derived breast-shaped phantoms were compared to those generated using a simpler cylindrical phantom using a constant volume, and the following constraints: (1) Length=1.5*radius; (2) radius determined at chest wall (Rcw), and (3) radius determined at the phantom center-of-mass (Rcm). Results: The change in Dg-NCT coefficients averaged across all phantom sizes, was - 0.5%, 19.8%, and 1.3%, for constraints 1–3, respectively. This suggests that the cylindrical assumption is a good approximation if the radius is taken at the breast center-of-mass, but using the radius at the chest wall results in an underestimation of the glandular dose. Conclusion: The DgN-CT coefficients for bCT-derived phantoms were compared against the assumption of a cylindrical phantom and proved to be essentially equivalent when the cylinder radius was set to r=1.5/L or Rcm. While this suggests that for dosimetry applications a patient’s breast can be approximated as a cylinder (if the correct radius is applied), this assumes a homogenous composition of breast tissue and the results may be different if the realistic heterogeneous distribution of glandular tissue is considered

  10. {sup 18}F-FDG PET/CT in the early prediction of pathological response in aggressive subtypes of breast cancer: review of the literature and recommendations for use in clinical trials

    Energy Technology Data Exchange (ETDEWEB)

    Groheux, David [Saint-Louis Hospital, Department of Nuclear Medicine, Paris Cedex 10 (France); INSERM/CNRS UMR944/7212, University Paris-Diderot, PRES Paris Cite, Paris (France); Mankoff, David [University of Pennsylvania Perelman School of Medicine, Department of Radiology, Philadelphia (United States); Espie, Marc [INSERM/CNRS UMR944/7212, University Paris-Diderot, PRES Paris Cite, Paris (France); Saint-Louis Hospital, Department of Medical Oncology, Breast Diseases Centre, Paris (France); Hindie, Elif [University of Bordeaux, Department of Nuclear Medicine, Haut-Leveque Hospital, Bordeaux (France)

    2016-05-15

    Early assessment of response to neoadjuvant chemotherapy (NAC) might be helpful in avoiding the toxicity of ineffective chemotherapy and allowing refinement of treatment. We conducted a review of the literature regarding the applicability of {sup 18}F-FDG PET/CT to the prediction of an early pathological response in different subgroups of breast cancer. Clinical research in this field has intensified in the last few years. Early studies by various groups have shown the potential of {sup 18}F-FDG PET/CT in the early assessment of response to NAC. However, interim PET/CT in breast cancer has not yet gained wide acceptance compared to its use in other settings such as lymphomas. This is in part due to a lack of consensus that early evaluation of response can be used to direct change in therapy in the neoadjuvant breast cancer setting, and only limited data showing that response-adaptive therapy leads to improved outcomes. However, one major element that has hampered the use of {sup 18}F-FDG PET/CT in directing neoadjuvant therapy is its evaluation in populations with mixed subtypes of breast cancer. However, major improvements have occurred in recent years. Pilot studies have highlighted the need for considering breast cancer subtype and the type of treatment, and have offered criteria for the use of PET/CT for the early prediction of response in specific settings. {sup 18}F-FDG PET/CT has considerable potential for the early prediction of pathological complete response to NAC in aggressive subtypes such as triple-negative or HER2-positive breast cancers. The results of a multicentre trial that used early metabolic response on {sup 18}F-FDG PET/CT as a means to select poor responders to adapt neoadjuvant treatment have recently been published. Other trials are ongoing or being planned. (orig.)

  11. High-Speed Data Acquisition and Digital Signal Processing System for PET Imaging Techniques Applied to Mammography

    Science.gov (United States)

    Martinez, J. D.; Benlloch, J. M.; Cerda, J.; Lerche, Ch. W.; Pavon, N.; Sebastia, A.

    2004-06-01

    This paper is framed into the Positron Emission Mammography (PEM) project, whose aim is to develop an innovative gamma ray sensor for early breast cancer diagnosis. Currently, breast cancer is detected using low-energy X-ray screening. However, functional imaging techniques such as PET/FDG could be employed to detect breast cancer and track disease changes with greater sensitivity. Furthermore, a small and less expensive PET camera can be utilized minimizing main problems of whole body PET. To accomplish these objectives, we are developing a new gamma ray sensor based on a newly released photodetector. However, a dedicated PEM detector requires an adequate data acquisition (DAQ) and processing system. The characterization of gamma events needs a free-running analog-to-digital converter (ADC) with sampling rates of more than 50 Ms/s and must achieve event count rates up to 10 MHz. Moreover, comprehensive data processing must be carried out to obtain event parameters necessary for performing the image reconstruction. A new generation digital signal processor (DSP) has been used to comply with these requirements. This device enables us to manage the DAQ system at up to 80 Ms/s and to execute intensive calculi over the detector signals. This paper describes our designed DAQ and processing architecture whose main features are: very high-speed data conversion, multichannel synchronized acquisition with zero dead time, a digital triggering scheme, and high throughput of data with an extensive optimization of the signal processing algorithms.

  12. Monte Carlo evaluation of glandular dose in cone-beam X-ray computed tomography dedicated to the breast: Homogeneous and heterogeneous breast models.

    Science.gov (United States)

    Sarno, Antonio; Mettivier, Giovanni; Tucciariello, Raffaele M; Bliznakova, Kristina; Boone, John M; Sechopoulos, Ioannis; Di Lillo, Francesca; Russo, Paolo

    2018-06-07

    In cone-beam computed tomography dedicated to the breast (BCT), the mean glandular dose (MGD) is the dose metric of reference, evaluated from the measured air kerma by means of normalized glandular dose coefficients (DgN CT ). This work aimed at computing, for a simple breast model, a set of DgN CT values for monoenergetic and polyenergetic X-ray beams, and at validating the results vs. those for patient specific digital phantoms from BCT scans. We developed a Monte Carlo code for calculation of monoenergetic DgN CT coefficients (energy range 4.25-82.25 keV). The pendant breast was modelled as a cylinder of a homogeneous mixture of adipose and glandular tissue with glandular fractions by mass of 0.1%, 14.3%, 25%, 50% or 100%, enveloped by a 1.45 mm-thick skin layer. The breast diameter ranged between 8 cm and 18 cm. Then, polyenergetic DgN CT coefficients were analytically derived for 49-kVp W-anode spectra (half value layer 1.25-1.50 mm Al), as in a commercial BCT scanner. We compared the homogeneous models to 20 digital phantoms produced from classified 3D breast images. Polyenergetic DgN CT resulted 13% lower than most recent published data. The comparison vs. patient specific breast phantoms showed that the homogeneous cylindrical model leads to a DgN CT percentage difference between -15% and +27%, with an average overestimation of 8%. A dataset of monoenergetic and polyenergetic DgN CT coefficients for BCT was provided. Patient specific breast models showed a different volume distribution of glandular dose and determined a DgN CT 8% lower, on average, than homogeneous breast model. Copyright © 2018 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  13. X-ray scatter correction method for dedicated breast computed tomography: improvements and initial patient testing

    International Nuclear Information System (INIS)

    Ramamurthy, Senthil; D’Orsi, Carl J; Sechopoulos, Ioannis

    2016-01-01

    A previously proposed x-ray scatter correction method for dedicated breast computed tomography was further developed and implemented so as to allow for initial patient testing. The method involves the acquisition of a complete second set of breast CT projections covering 360° with a perforated tungsten plate in the path of the x-ray beam. To make patient testing feasible, a wirelessly controlled electronic positioner for the tungsten plate was designed and added to a breast CT system. Other improvements to the algorithm were implemented, including automated exclusion of non-valid primary estimate points and the use of a different approximation method to estimate the full scatter signal. To evaluate the effectiveness of the algorithm, evaluation of the resulting image quality was performed with a breast phantom and with nine patient images. The improvements in the algorithm resulted in the avoidance of introduction of artifacts, especially at the object borders, which was an issue in the previous implementation in some cases. Both contrast, in terms of signal difference and signal difference-to-noise ratio were improved with the proposed method, as opposed to with the correction algorithm incorporated in the system, which does not recover contrast. Patient image evaluation also showed enhanced contrast, better cupping correction, and more consistent voxel values for the different tissues. The algorithm also reduces artifacts present in reconstructions of non-regularly shaped breasts. With the implemented hardware and software improvements, the proposed method can be reliably used during patient breast CT imaging, resulting in improvement of image quality, no introduction of artifacts, and in some cases reduction of artifacts already present. The impact of the algorithm on actual clinical performance for detection, diagnosis and other clinical tasks in breast imaging remains to be evaluated. (paper)

  14. Diagnostic value of FDG PET-CT for detecting primary breast malignancy: comparison with other image modalities and histopathologic correlation

    International Nuclear Information System (INIS)

    Jung, Na Young; Lee, Jae Hee; Kim, Chung Ho; Yoo, Ie Ryung; Kim, Sung Hoon; Chung, Yong An; Sohn, Hyung Sun; Chung, Soo Kyo; Jung, Sang Seol

    2004-01-01

    To compare the diagnostic value of 18F-FDG PET-CT in detecting the primary breast malignancy with other imaging modalities and to determine whether detectability of PET-CT depends on any factors such as size, differentiation, or nuclear grade of tumor. We evaluated pathologically proven 66 lesions in 61 patients (26-74 years, mean 46.9) who underwent preoperative PET-CT. Other imaging modalities were also evaluated: mammography in 58, US in 49 and MRI in 16. PET-CT images were visually evaluated and peak and mean SUV of mass were measured. For mammography and US, category 4 and 5 lesions as positive, and category 0-3 lesions as negative. For MRI, we used morphology and dynamic kinetic curve data based scoring system; sum of the scores higher than 10 as positive. Sensitivities of each modality were obtained. We analyzed PET-CT positive and negative groups in relation to size, SUV, differentiation and nuclear grade of tumors using paired t-test and Fisher's exact test. 65 among 66 were malignant lesions: invasive ductal carcinoma (n=56), ductal carcinoma in situ (n=3), tubular carcinoma (n=1), medullary carcinoma(n=3), mucinous carcinoma(n=1) and malignant fibrous histiocytoma (n=1). One lesion was benign lesion. Sensitivities of PET-CT, mammography, US, and MRI for detecting malignant mass were 86.2%, 80.7%, 100% and 94.1% respectively. SUV(P) and SUV(M) in PET-CT positive group (5.28±3.24 and 3.56±2.24) was significantly higher than that of PET CT negative group (1.96±0.35 and 1.46±0.44) [p<0.0001 for both]. The size of the primary mass in PET-CT positive group (2.66±1.47) was significantly larger than that in PET-CT negative group (1.52±0.57) (p=0.0002). The nuclear grade and tumor differentiation were not significantly different between two groups. The sensitivity of the FDG PET-CT in detecting primary breast cancer is lower than those of other imaging modalities. The detectability of the FDG PET-CT might be degraded when the tumor is small in size

  15. Usefulness of Integrated PET/MRI in Head and Neck Cancer: A Preliminary Study

    International Nuclear Information System (INIS)

    Lee, Soo Jin; Seo, Hyo Jung; Cheon, Gi Jeong; Kim, Ji Hoon; Kim, E. Edmund; Kang, Keon Wook; Paeng, Jin Chul; Chung, Junekey; Lee, Dong Soo

    2014-01-01

    The new modality of an integrated positron emission tomography/magnetic resonance imaging (PET/MRI) has recently been introduced but not validated. Our objective was to evaluate clinical performance of 18 F-fluoro-2-deoxyglucose ( 18 F-FDG) PET/MRI in patients with head and neck cancer. This retrospective study was conducted between January 2013 and February 2013. Ten patients (eight men, two women; mean age, 61.4±13.4 years) with histologically proven head and neck tumors were enrolled.Whole-body PET/MRI and regional positron emission tomography (PET) with dedicated MRI were sequentially obtained. Maximum standardized uptake value (SUVmax), SUVmean, metabolic tumor volume, total lesion glycolysis and contrast enhancement were analyzed. A total of ten whole-body positron emission tomography (PET), ten regional positron emission tomography (PET), ten dedicated MRI and ten regional PET/gadolinium-enhanced T1-weighted (Gd)-MRI images were analyzed for initial staging. Two nuclear medicine physicians analyzed positron emission tomography (PET) and PET/MRI with a consensus. One radiologist analyzed dedicated MRI. The primary lesions and number of metastatic lymph nodes analyzed from each image were compared. Eight patients were diagnosed with head and neck cancer (one tongue cancer, four tonsillar cancers, one nasopharyngeal cancer and two hypopharyngeal cancers) by histological diagnosis. Two benign tumors (pleomorphic adenoma and Warthin tumor) were diagnosed with surgical operation. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) attenuated by MRI showed good image quality for the lesion detection. Whole-body positron emission tomography (PET) and regional positron emission tomography (PET) detected ten primary sites and compensated for a missed lesion on dedicated MRI. A discordant number of suspicious lymph node metastases was noted according to the different images; 22, 16, 39 and 40 in the whole-body positron

  16. Unusual Horner's syndrome in recurrent breast cancer: Evaluating using {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Park, So Hyun; Kim, Tae Sung; Kim, Seok Ki [Dept. of Nuclear Medicine, National Cancer Center, Goyang (Korea, Republic of)

    2017-03-15

    {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) is a widely used imaging modality in the initial diagnosis of cancer, treatment response evaluation and detection of recurrence. Herein, we present the case of a 39-year-old female who presented right ptosis on the follow-up of breast cancer after surgery. Clinicians suspected Horner's syndrome, and the patient underwent FDG PET/CT for the evaluation of recurrence that could cause Horner's syndrome. FDG PET/CT demonstrated a focal hypermetabolic lesion in the right cervicothoracic junction area, corresponding to the preganglionic cervical sympathetic trunk. A subsequent needle biopsy was done, and the lesion was confirmed as metastatic ductal carcinoma. In this case, we could detect the exact location of the recurring lesion that caused Horner's syndrome using FDG PET/CT.

  17. Integrated {sup 18}F-FDG PET/MRI in breast cancer. Early prediction of response to neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Nariya [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Seoul National University Medical Research Center, Institute of Radiation Medicine, Seoul (Korea, Republic of); Im, Seock-Ah; Lee, Kyung-Hun; Kim, Tae-Yong [Seoul National University College of Medicine, Department of Internal Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Cheon, Gi Jeong [Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Park, In-Ae [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Kim, Young Seon [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Yeungnam University, Department of Radiology, College of Medicine, Daegu (Korea, Republic of); Kwon, Bo Ra [Seoul National University Hospital, Department of Radiology, Seoul (Korea, Republic of); Lee, Jung Min; Suh, Hoon Young [Seoul National University Hospital, Department of Nuclear Medicine, Seoul (Korea, Republic of); Suh, Koung Jin [Seoul National University College of Medicine, Department of Internal Medicine, Seoul (Korea, Republic of)

    2018-03-15

    To explore whether integrated {sup 18}F-FDG PET/MRI can be used to predict pathological response to neoadjuvant chemotherapy (NAC) in patients with breast cancer. Between November 2014 and April 2016, 26 patients with breast cancer who had received NAC and subsequent surgery were prospectively enrolled. Each patient underwent {sup 18}F-FDG PET/MRI examination before and after the first cycle of NAC. Qualitative MRI parameters, including morphological descriptors and the presence of peritumoral oedema were assessed. Quantitatively, PET parameters, including maximum standardized uptake value, metabolic tumour volume and total lesion glycolysis (TLG), and MRI parameters, including washout proportion and signal enhancement ratio (SER), were measured. The performance of the imaging parameters singly and in combination in predicting a pathological incomplete response (non-pCR) was assessed. Of the 26 patients, 7 (26.9%) exhibited a pathological complete response (pCR), and 19 (73.1%) exhibited a non-pCR. No significant differences were found between the pCR and non-pCR groups in the qualitative MRI parameters. The mean percentage reductions in TLG{sub 30%} on PET and SER on MRI were significantly greater in the pCR group than in the non-pCR group (TLG{sub 30%} -64.8 ± 15.5% vs. -25.4 ± 48.7%, P = 0.005; SER -34.6 ± 19.7% vs. -8.7 ± 29.0%, P = 0.040). The area under the receiver operating characteristic curve for the percentage change in TLG{sub 30%} (0.789, 95% CI 0.614 to 0.965) was similar to that for the percentage change in SER (0.789, 95% CI 0.552 to 1.000; P = 1.000). The specificity of TLG{sub 30%} in predicting pCR was 100% (7/7) and that of SER was 71.4% (5/7). The sensitivity of TLG{sub 30%} in predicting non-pCR was 63.2% (12/19) and that of SER was 84.2% (16/19). When the combined TLG{sub 30%} and SER criterion was applied, sensitivity was 100% (19/19), and specificity was 71.4% (5/7). {sup 18}F-FDG PET/MRI can be used to predict non-pCR after the first

  18. Role of {sup 18}F-FDG PET-CT in monitoring the cyclophosphamide induced pulmonary toxicity in patients with breast cancer - 2 Case Reports

    Energy Technology Data Exchange (ETDEWEB)

    Taywade, Sameer Kamalakar; Kumar, Rakesh; Bhethanabhotla, Sainath; Bal, Chandrasekhar [A.I.I.M.S, New Delhi (India)

    2016-09-15

    Drug induced pulmonary toxicity is not uncommon with the use of various chemotherapeutic agents. Cyclophosphamide is a widely used chemotherapeutic drug in the treatment of breast cancer. Although rare, lung toxicity has been reported with cyclophosphamide use. Detection of bleomycin induced pulmonary toxicity and pattern of {sup 18}F-fluorodeoxyglucose ({sup 18}F-FDG) uptake in lungs on fluorodeoxyglucose positron emission tomography-computed tomography ({sup 18}F-FDG PET-CT) has been elicited in literature in relation to lymphoma. However, limited data is available regarding the role of {sup 18}F-FDG PET-CT in monitoring drug induced pulmonary toxicity in breast cancer. We here present two cases of cyclophosphamide induced drug toxicity. Interim {sup 18}F-FDG PET-CT demonstrated diffusely increased tracer uptake in bilateral lung fields in both these patients. Subsequently there was resolution of lung uptake on {sup 18}F-FDG PET-CT scan post completion of chemotherapy. These patients did not develop significant respiratory symptoms during chemotherapy treatment and in follow up.

  19. Strategies of statistical windows in PET image reconstruction to improve the user’s real time experience

    Science.gov (United States)

    Moliner, L.; Correcher, C.; Gimenez-Alventosa, V.; Ilisie, V.; Alvarez, J.; Sanchez, S.; Rodríguez-Alvarez, M. J.

    2017-11-01

    Nowadays, with the increase of the computational power of modern computers together with the state-of-the-art reconstruction algorithms, it is possible to obtain Positron Emission Tomography (PET) images in practically real time. These facts open the door to new applications such as radio-pharmaceuticals tracking inside the body or the use of PET for image-guided procedures, such as biopsy interventions, among others. This work is a proof of concept that aims to improve the user experience with real time PET images. Fixed, incremental, overlapping, sliding and hybrid windows are the different statistical combinations of data blocks used to generate intermediate images in order to follow the path of the activity in the Field Of View (FOV). To evaluate these different combinations, a point source is placed in a dedicated breast PET device and moved along the FOV. These acquisitions are reconstructed according to the different statistical windows, resulting in a smoother transition of positions for the image reconstructions that use the sliding and hybrid window.

  20. Comparison of the diagnostic value of FDG-PET/CT and axillary ultrasound for the detection of lymph node metastases in breast cancer patients

    International Nuclear Information System (INIS)

    Riegger, Carolin; Heusner, Till A.; Koeninger, Angela; Kimmig, Rainer; Hartung, Verena; Bockisch, Andreas; Otterbach, Friedrich; Forsting, Michael; Antoch, Gerald

    2012-01-01

    Background. FDG-PET/CT is increasingly being used for breast cancer staging. Its diagnostic accuracy in comparison to ultrasound as the standard non-invasive imaging modality for the evaluation of axillary lymph nodes has yet not been evaluated. Purpose. To retrospectively compare the diagnostic value of full-dose, intravenously contrast-enhanced FDG-PET/CT and ultrasound for the detection of lymph node metastases in breast cancer patients. Material and Methods. Ninety patients (one patient with a bilateral carcinoma) (89 women, one man; mean age, 55.5 ± 16.6 years) suffering from primary breast cancer underwent whole-body FDG-PET/CT and axillary ultrasound. The ipsilateral axillary fossa (n = 91) was evaluated for metastatic spread. The sensitivity, specificity, the positive predictive value (PPV), negative predictive value (NPV), and accuracy of both methods were calculated. The sensitivity and accuracy were statistically compared using the McNemar Test (P <0.05). Analyses were made on a patient basis. The number of patients with extra-axillary locoregional lymph node metastases exclusively detected by FDG-PET/CT was evaluated. For axillary lymph node metastases histopathology served as the reference standard. Results. The sensitivity, specificity, PPV, NPV, and accuracy of FDG-PET/CT for the detection of axillary lymph node metastases were 54%, 89%, 77%, 74%, and 75%, respectively. For ultrasound it was 38%, 78%, 54%, 65%, and 62%, respectively. FDG-PET/CT was significantly more accurate than ultrasound for the detection of axillary lymph node metastases (P = 0.019). There was no statistically significant difference between the sensitivity of both modalities (P = 0.0578). FDG-PET/CT detected extra-axillary locoregional lymph node metastases in seven patients (8%) that had not been detected by another imaging modality. Conclusion. Though more accurate compared to ultrasound for evaluating the axillary lymph node status FDG-PET/CT is only as sensitive as

  1. Thoracic staging in lung cancer: prospective comparison of 18F-FDG PET/MR imaging and 18F-FDG PET/CT.

    Science.gov (United States)

    Heusch, Philipp; Buchbender, Christian; Köhler, Jens; Nensa, Felix; Gauler, Thomas; Gomez, Benedikt; Reis, Henning; Stamatis, Georgios; Kühl, Hilmar; Hartung, Verena; Heusner, Till A

    2014-03-01

    Therapeutic decisions in non-small cell lung cancer (NSCLC) patients depend on the tumor stage. PET/CT with (18)F-FDG is widely accepted as the diagnostic standard of care. The purpose of this study was to compare a dedicated pulmonary (18)F-FDG PET/MR imaging protocol with (18)F-FDG PET/CT for primary and locoregional lymph node staging in NSCLC patients using histopathology as the reference. Twenty-two patients (12 men, 10 women; mean age ± SD, 65.1 ± 9.1 y) with histopathologically confirmed NSCLC underwent (18)F-FDG PET/CT, followed by (18)F-FDG PET/MR imaging, including a dedicated pulmonary MR imaging protocol. T and N staging according to the seventh edition of the American Joint Committee on Cancer staging manual was performed by 2 readers in separate sessions for (18)F-FDG PET/CT and PET/MR imaging, respectively. Results from histopathology were used as the standard of reference. The mean and maximum standardized uptake value (SUV(mean) and SUV(max), respectively) and maximum diameter of the primary tumor was measured and compared in (18)F-FDG PET/CT and PET/MR imaging. PET/MR imaging and (18)F-FDG PET/CT agreed on T stages in 16 of 16 of patients (100%). All patients were correctly staged by (18)F-FDG PET/CT and PET/MR (100%), compared with histopathology. There was no statistically significant difference between (18)F-FDG PET/CT and (18)F-FDG PET/MR imaging for lymph node metastases detection (P = 0.48). For definition of thoracic N stages, PET/MR imaging and (18)F-FDG PET/CT were concordant in 20 of 22 patients (91%). PET/MR imaging determined the N stage correctly in 20 of 22 patients (91%). (18)F-FDG PET/CT determined the N stage correctly in 18 of 22 patients (82%). The mean differences for SUV(mean) and SUV(max) of NSCLC in (18)F-FDG PET/MR imaging and (18)F-FDG PET/CT were 0.21 and -5.06. These differences were not statistically significant (P > 0.05). The SUV(mean) and SUV(max) measurements derived from (18)F-FDG PET/CT and (18)F-FDG PET

  2. Asesoramiento y diseño ergonómico de la camilla para el mamógrafo MAMMI

    OpenAIRE

    Morales Martín, Iñigo; Navarro Garcia, Francisco Jose; LÓPEZ LÓPEZ, JOAQUÍN; ATIENZA VICENTE, CARLOS MANUEL; Solera Navarro, Mª Jesús; González Martínez, Antonio Javier; CABALLERO ONTANAYA, LUIS; Vidal San Sebastian, Luis Fernando; Moine, Séverine

    2011-01-01

    [EN] The Instituto de Biomecánica (IBV) takes part in the development of a dedicated stretcher to be used with the new breast PET of the company ONCOVISION. This device called MAMMI is the clinical PET system with the highest spatial resolution in the market, specifically dedicated to breast cancer detection in early stages and its assessment in later phases. The IBV assessed ONCOVISION in the design, manufacturing, and mechanical tests of the stretcher...

  3. Physical effects of mechanical design parameters on photon sensitivity and spatial resolution performance of a breast-dedicated PET system.

    Science.gov (United States)

    Spanoudaki, V C; Lau, F W Y; Vandenbroucke, A; Levin, C S

    2010-11-01

    This study aims to address design considerations of a high resolution, high sensitivity positron emission tomography scanner dedicated to breast imaging. The methodology uses a detailed Monte Carlo model of the system structures to obtain a quantitative evaluation of several performance parameters. Special focus was given to the effect of dense mechanical structures designed to provide mechanical robustness and thermal regulation to the minuscule and temperature sensitive detectors. For the energies of interest around the photopeak (450-700 keV energy window), the simulation results predict a 6.5% reduction in the single photon detection efficiency and a 12.5% reduction in the coincidence photon detection efficiency in the case that the mechanical structures are interspersed between the detectors. However for lower energies, a substantial increase in the number of detected events (approximately 14% and 7% for singles at a 100-200 keV energy window and coincidences at a lower energy threshold of 100 keV, respectively) was observed with the presence of these structures due to backscatter. The number of photon events that involve multiple interactions in various crystal elements is also affected by the presence of the structures. For photon events involving multiple interactions among various crystal elements, the coincidence photon sensitivity is reduced by as much as 20% for a point source at the center of the field of view. There is no observable effect on the intrinsic and the reconstructed spatial resolution and spatial resolution uniformity. Mechanical structures can have a considerable effect on system sensitivity, especially for systems processing multi-interaction photon events. This effect, however, does not impact the spatial resolution. Various mechanical structure designs are currently under evaluation in order to achieve optimum trade-off between temperature stability, accurate detector positioning, and minimum influence on system performance.

  4. Sub-millimetre DOI detector based on monolithic LYSO and digital SiPM for a dedicated small-animal PET system

    International Nuclear Information System (INIS)

    Marcinkowski, Radosław; Mollet, Pieter; Van Holen, Roel; Vandenberghe, Stefaan

    2016-01-01

    The mouse model is widely used in a vast range of biomedical and preclinical studies. Thanks to the ability to detect and quantify biological processes at the molecular level in vivo, PET has become a well-established tool in these investigations. However, the need to visualize and quantify radiopharmaceuticals in anatomic structures of millimetre or less requires good spatial resolution and sensitivity from small-animal PET imaging systems. In previous work we have presented a proof-of-concept of a dedicated high-resolution small-animal PET scanner based on thin monolithic scintillator crystals and Digital Photon Counter photosensor. The combination of thin monolithic crystals and MLE positioning algorithm resulted in an excellent spatial resolution of 0.7 mm uniform in the entire field of view (FOV). However, the limitation of the scanner was its low sensitivity due to small thickness of the lutetium-yttrium oxyorthosilicate (LYSO) crystals (2 mm). Here we present an improved detector design for a small-animal PET system that simultaneously achieves higher sensitivity and sustains a sub-millimetre spatial resolution. The proposed detector consists of a 5 mm thick monolithic LYSO crystal optically coupled to a Digital Photon Counter. Mean nearest neighbour (MNN) positioning combined with depth of interaction (DOI) decoding was employed to achieve sub-millimetre spatial resolution. To evaluate detector performance the intrinsic spatial resolution, energy resolution and coincidence resolving time (CRT) were measured. The average intrinsic spatial resolution of the detector was 0.60 mm full-width-at-half-maximum (FWHM). A DOI resolution of 1.66 mm was achieved. The energy resolution was 23% FWHM at 511 keV and CRT of 529 ps were measured. The improved detector design overcomes the sensitivity limitation of the previous design by increasing the nominal sensitivity of the detector block and retains an excellent intrinsic spatial resolution. (paper)

  5. PET scanning in plastic and reconstructive surgery.

    Science.gov (United States)

    Liodaki, Eirini; Eirini, Liodaki; Liodakis, Emmanouil; Emmanouil, Liodakis; Papadopoulos, Othonas; Othonas, Papadopoulos; Machens, Hans-Günther; Hans-Günther, Machens; Papadopulos, Nikolaos A; Nikolaos, Papadopulos A

    2012-02-01

    In this report we highlight the use of PET scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge.

  6. Discussion on the alteration of FDG uptake by the breast according to the menstrual cycle in 18F-FDG PET/CT

    Science.gov (United States)

    Park, H. H.; Park, M. S.; Lee, C. H.; Cho, J. H.; Dong, K. R.; Chung, W. K.

    2012-09-01

    18F-FDG (fluorodeoxyglucose) PET (positron emission tomography)/CT (computed tomography) is a useful modality for identifying high-glucose-consuming cells, such as cancer cells, by the glucose metabolism of FDG. FDG is taken up by cancer and inflammatory cells, but occasionally there is also some FDG uptake by normal tissues as a result of their individual physiological characteristics. In particular, in fertile females, unusual FDG uptake in the breast changes according to the stages in the menstrual cycle, which can adversely affect a diagnosis. Therefore, this study examined the change in breast FDG uptake in the menstrual cycle on 18F-FDG PET/CT. One hundred and sixty females (34±3.5 years old), who had not undergone a gynecologic anamnesis and had a regular menstrual cycle over the previous 6 months, were examined from March 2010 to February 2011. The subjects were divided into the following four groups (each with 40 patients): flow phase, proliferative phase, ovulatory phase and secretory phase using Pregnancy Calculator Ver. 0.14 and history taking. Discovery Ste was used as the PET/CT. The standardized uptake values (SUVs) on the accumulated region on the breast were analyzed, and three nuclear medicine specialists performed a blind test. The SUVs on the breast were the flow phase (1.64±0.25), proliferative phase (0.93±0.28), ovulatory phase (1.66±0.26) and secretory phase (1.77±0.28). A high uptake value was observed in the secretory, flow and ovulatory phases. The FDG accumulation of the breast was divided into the following three grades compared with the lung and liver by gross analysis: the breast uptake was equal to the lung (Grade I), between the lung and liver (Grade II) and equal to or greater than the liver (Grade III). These results showed a high uptake value in the secretory, flow and ovulatory phases. In fertile females, the FDG uptake of the breast showed changes according to the menstrual cycle, which can be used to improve the diagnosis

  7. A pilot study of FDG PET/CT detects a link between brown adipose tissue and breast cancer

    International Nuclear Information System (INIS)

    Cao, Qi; Jones, Laundette; Hersl, Jerome; La, Hongloan; Smith, Mark; Jenkins, Jason; Goloubeva, Olga; Dilsizian, Vasken; Tkaczuk, Katherine; Chen, Wengen

    2014-01-01

    Breast cancer is the second most lethal cancer in women. Understanding biological mechanisms that cause progression of this disease could yield new targets for prevention and treatment. Recent experimental studies suggest that brown adipose tissue (BAT) may play a key role in breast cancer progression. The primary objective for this pilot study was to determine if the prevalence of active BAT in patients with breast cancer is increased compared to cancer patients with other malignancies. We retrospectively analyzed data from 96 breast cancer patients who had FDG PET/CT scan for routine staging at the University of Maryland and 96 age- and weight-matched control female patients with other malignancies (predominantly colon cancer) who had undergone FDG PET/CT imaging on the same day. Data on the distribution (bilateral upper neck, supraclavicular and paraspinal regions) and intensity (SUVmax) of active BAT were evaluated by 2 Nuclear Medicine physicians, blinded to the clinical history. We found sufficient evidence to conclude that based on our sample data the prevalence of active BAT in breast cancer patients’ group is significantly different from that in the control group. The estimated frequency of BAT activity was 3 fold higher in breast cancer patients as compared to controls with other cancers, (16.7% vs. 5.2%, respectively, p = 0.019). When patients were stratified by age in order to determine the possible impact of age related hormonal changes on active BAT among the younger women (≤ 55 years of age), 25.6% breast cancer patients exhibited BAT activity compared to only 2.8% in control women (p = 0.007). In contrast, among the older women (> 55 years of age), the prevalence of active BAT was similar among breast cancer and control women (10.7% vs 6.7%). In breast cancer patients prevalence of BAT activity on FDGPET/CT is 3-fold greater than in age- and body weight-matched patients with other solid tumor malignancies; this difference is particularly

  8. Incremental clinical value of a dedicated RT planning FDG PET-CT over staging PET-CT in non-small cell lung cancer

    International Nuclear Information System (INIS)

    Lin, P.; Som, S.; Vinod, S.; Lin, M.; Shon, I. H.

    2009-01-01

    Full text:Objectives: To evaluate whether FDG-PET performed for radiotherapy planning can detect disease progression, compared with staging PET. Methods: Thirteen patients underwent a planning PET-CT for curative RT ( R T-PET ) within eight weeks of a staging PET-CT for newly diagnosed NSCLC between 10/2007 and 1/2009. All studies were acquired on a Philips GXL PET-CT using the same protocols, except RT-PET is acquired on a RT flat bed. The images were interpreted by consensus readings of two physicians: location/number, visual grading (0-4:3> liver, 4>brain), max transverse diameter ( M ax D ) (tumour margin is delineated by a SUV threshold of 2.5) and max SUV of each lesion. Progressive disease (PD) is defined as >10% increase in max D. Results: RT-PET detected PD (primary or nodal) or new metastases in 8 pts (61%) (mean interval:30.2±14 days, range:7-54 days). For primary tumour, RT-PET detected PD in 5

  9. Assessing the role of {sup 18}F-FDG PET and {sup 18}F-FDG PET/CT in the diagnosis of soft tissue musculoskeletal malignancies: a systematic review and meta-analysis

    Energy Technology Data Exchange (ETDEWEB)

    Etchebehere, Elba C. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States); Sirio Libanes Hospital, Department of Nuclear Medicine, Sao Paulo (Brazil); Hobbs, Brian P.; Milton, Denai R. [The University of Texas MD Anderson Cancer Center, Department of Biostatistics, Houston, TX (United States); Malawi, Osama [The University of Texas MD Anderson Cancer Center, Department of Imaging Physics, Houston, TX (United States); Patel, Shreyaskumar; Benjamin, Robert S. [The University of Texas MD Anderson Cancer Center, Department of Sarcoma Medical Oncology, Houston, TX (United States); Macapinlac, Homer A. [The University of Texas MD Anderson Cancer Center, Department of Nuclear Medicine, Houston, TX (United States)

    2016-05-15

    Twelve years ago a meta-analysis evaluated the diagnostic performance of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET) in assessing musculoskeletal soft tissue lesions (MsSTL). Currently, PET/CT has substituted PET imaging; however, there has not been any published meta-analysis on the use of PET/CT or a comparison of PET/CT with PET in the diagnosis of MsSTL. Therefore, we conducted a meta-analysis to identify the current diagnostic performance of {sup 18}F-FDG PET/CT and determine if there is added value when compared to PET. A systematic review of English articles was conducted, and MEDLINE PubMed, the Cochrane Library, and Embase were searched from 1996 to March 2015. Studies exploring the diagnostic accuracy of {sup 18}F-FDG PET/CT (or dedicated PET) compared to histopathology in patients with MsSTL undergoing investigation for malignancy were included. Our meta-analysis included 14 articles composed of 755 patients with 757 soft tissue lesions. There were 451 (60 %) malignant tumors and 306 benign lesions. The {sup 18}F-FDG PET/CT (and dedicated PET) mean sensitivity, specificity, accuracy, positive predictive value, and negative predictive value for diagnosing MsSTL were 0.96 (0.90, 1.00), 0.77 (0.67, 0.86), 0.88 (0.85, 0.91), 0.86 (0.78, 0.94), and 0.91 (0.83, 0.99), respectively. The posterior mean (95 % highest posterior density interval) for the AUC was 0.92 (0.88, 0.96). PET/CT had higher specificity, accuracy, and positive predictive value when compared to a dedicated PET (0.85, 0.89, and 0.91 vs 0.71, 0.85, and 0.82, respectively). {sup 18}F-FDG PET/CT and dedicated PET are both highly accurate in the diagnosis of MsSTL. PET/CT is more accurate and specific and has a higher positive predictive value than PET. (orig.)

  10. Evaluation of the BreastSimulator software platform for breast tomography

    Science.gov (United States)

    Mettivier, G.; Bliznakova, K.; Sechopoulos, I.; Boone, J. M.; Di Lillo, F.; Sarno, A.; Castriconi, R.; Russo, P.

    2017-08-01

    The aim of this work was the evaluation of the software BreastSimulator, a breast x-ray imaging simulation software, as a tool for the creation of 3D uncompressed breast digital models and for the simulation and the optimization of computed tomography (CT) scanners dedicated to the breast. Eight 3D digital breast phantoms were created with glandular fractions in the range 10%-35%. The models are characterised by different sizes and modelled realistic anatomical features. X-ray CT projections were simulated for a dedicated cone-beam CT scanner and reconstructed with the FDK algorithm. X-ray projection images were simulated for 5 mono-energetic (27, 32, 35, 43 and 51 keV) and 3 poly-energetic x-ray spectra typically employed in current CT scanners dedicated to the breast (49, 60, or 80 kVp). Clinical CT images acquired from two different clinical breast CT scanners were used for comparison purposes. The quantitative evaluation included calculation of the power-law exponent, β, from simulated and real breast tomograms, based on the power spectrum fitted with a function of the spatial frequency, f, of the form S(f)  =  α/f   β . The breast models were validated by comparison against clinical breast CT and published data. We found that the calculated β coefficients were close to that of clinical CT data from a dedicated breast CT scanner and reported data in the literature. In evaluating the software package BreastSimulator to generate breast models suitable for use with breast CT imaging, we found that the breast phantoms produced with the software tool can reproduce the anatomical structure of real breasts, as evaluated by calculating the β exponent from the power spectral analysis of simulated images. As such, this research tool might contribute considerably to the further development, testing and optimisation of breast CT imaging techniques.

  11. Trends in PET imaging

    International Nuclear Information System (INIS)

    Moses, William W.

    2000-01-01

    Positron Emission Tomography (PET) imaging is a well established method for obtaining information on the status of certain organs within the human body or in animals. This paper presents an overview of recent trends PET instrumentation. Significant effort is being expended to develop new PET detector modules, especially those capable of measuring depth of interaction. This is aided by recent advances in scintillator and pixellated photodetector technology. The other significant area of effort is development of special purpose PET cameras (such as for imaging breast cancer or small animals) or cameras that have the ability to image in more than one modality (such as PET / SPECT or PET / X-Ray CT)

  12. Gamma-ray detectors for breast imaging

    Science.gov (United States)

    Williams, Mark B.; Goode, Allen R.; Majewski, Stan; Steinbach, Daniela; Weisenberger, Andrew G.; Wojcik, Randolph F.; Farzanpay, Farzin

    1997-07-01

    Breast cancer is the most common cancer of American women and is the leading cause of cancer-related death among women aged 15 - 54; however recent years have shown that early detection using x-ray mammography can lead to a high probability of cure. However, because of mammography's low positive predictive value, surgical or core biopsy is typically required for diagnosis. In addition, the low radiographic contrast of many nonpalpable breast masses, particularly among women with radiographically dense breasts, results in an overall rate of 10% to 25% for missed tumors. Nuclear imaging of the breast using single gamma emitters (scintimammography) such as (superscript 99m)Tc, or positron emitters such as F-18- fluorodeoxyglucose (FDG) for positron emission tomography (PET), can provide information on functional or metabolic tumor activity that is complementary to the structural information of x-ray mammography, thereby potentially reducing the number of unnecessary biopsies and missed cancers. This paper summarizes recent data on the efficacy of scintimammography using conventional gamma cameras, and describes the development of dedicated detectors for gamma emission breast imaging. The detectors use new, high density crystal scintillators and large area position sensitive photomultiplier tubes (PSPMTs). Detector design, imaging requirements, and preliminary measured imaging performance are discussed.

  13. Correlation of breast cancer subtypes, based on estrogen receptor, progesterone receptor, and HER2, with functional imaging parameters from {sup 68}Ga-RGD PET/CT and {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Hai-Jeon [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, The Institute of Radiation Medicine, Seoul (Korea, Republic of); Ewha Womans University School of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Kang, Keon Wook; Jeong, Jae Min; Chung, June-Key [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Biomedical Sciences, Seoul (Korea, Republic of); Seoul National University College of Medicine, The Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Cancer Research Institute, Seoul (Korea, Republic of); Chun, In Kook [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Kangwon National University Hospital, Department of Nuclear Medicine, Chuncheon, Kangwon-Do (Korea, Republic of); Cho, Nariya [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Im, Seock-Ah [Seoul National University College of Medicine, Department of Internal Medicine, Seoul (Korea, Republic of); Jeong, Sunjoo [Dankook University, Department of Molecular Biology, Yongin (Korea, Republic of); Lee, Song [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, The Institute of Radiation Medicine, Seoul (Korea, Republic of); Jung, Kyeong Cheon [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Lee, Yun-Sang [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Molecular Medicine and Biopharmaceutical Sciences, Graduate School of Convergence Science and Technology, Seoul (Korea, Republic of); Lee, Dong Soo [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Seoul National University College of Medicine, The Institute of Radiation Medicine, Seoul (Korea, Republic of); Seoul National University, Department of Molecular Medicine and Biopharmaceutical Sciences, Seoul (Korea, Republic of); Moon, Woo Kyung [Seoul National University College of Medicine, Department of Radiology, Jongno-gu, Seoul (Korea, Republic of); Seoul National University College of Medicine, Department of Biomedical Sciences, Seoul (Korea, Republic of); Seoul National University College of Medicine, The Institute of Radiation Medicine, Seoul (Korea, Republic of)

    2014-08-15

    Imaging biomarkers from functional imaging modalities were assessed as potential surrogate markers of disease status. Specifically, in this prospective study, we investigated the relationships between functional imaging parameters and histological prognostic factors and breast cancer subtypes. In total, 43 patients with large or locally advanced invasive ductal carcinoma (IDC) were analyzed (47.6 ± 7.5 years old). {sup 68}Ga-Labeled arginine-glycine-aspartic acid (RGD) and {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) were performed. The maximum and average standardized uptake values (SUV{sub max} and SUV{sub avg}) from RGD PET/CT and SUV{sub max} and SUV{sub avg} from FDG PET/CT were the imaging parameters used. For histological prognostic factors, estrogen receptor (ER), progesterone receptor (PR), and human epidermal growth factor receptor 2 (HER2) expression was identified using immunohistochemistry (IHC) or fluorescent in situ hybridization (FISH). Four breast cancer subtypes, based on ER/PR and HER2 expression (ER/PR+,Her2-, ER/PR+,Her2+, ER/PR-,Her2+, and ER/PR-,Her2-), were considered. Quantitative FDG PET parameters were significantly higher in the ER-negative group (15.88 ± 8.73 vs 10.48 ± 6.01, p = 0.02 for SUV{sub max}; 9.40 ± 5.19 vs 5.92 ± 4.09, p = 0.02 for SUV{sub avg}) and the PR-negative group (8.37 ± 4.94 vs 4.79 ± 3.93, p = 0.03 for SUV{sub avg}). Quantitative RGD PET parameters were significantly higher in the HER2-positive group (2.42 ± 0.59 vs 2.90 ± 0.75, p = 0.04 for SUV{sub max}; 1.60 ± 0.38 vs 1.95 ± 0.53, p = 0.04 for SUV{sub avg}) and showed a significant positive correlation with the HER2/CEP17 ratio (r = 0.38, p = 0.03 for SUV{sub max} and r = 0.46, p < 0.01 for SUV{sub avg}). FDG PET parameters showed significantly higher values in the ER/PR-,Her2- subgroup versus the ER/PR+,Her2- or ER/PR+,Her2+ subgroups, while RGD PET parameters showed significantly lower values in the ER

  14. PET scanning in plastic and reconstructive surgery

    International Nuclear Information System (INIS)

    Eirini, L.; Emmanouil, L.; Othonas, P.; Hans-Guenther, M.; Nikolaos, P.A.

    2012-01-01

    In this report we highlight the use of position emission tomography (PET) scan in plastic and reconstructive surgery. PET scanning is a very important tool in plastic surgery oncology (melanoma, soft-tissue sarcomas and bone sarcomas, head and neck cancer, peripheral nerve sheath tumors of the extremities and breast cancer after breast esthetic surgery), as diagnosis, staging, treatment planning and follow-up of cancer patients is based on imaging. PET scanning seems also to be useful as a flap monitoring system as well as an infection's imaging tool, for example in the management of diabetic foot ulcer. PET also contributes to the understanding of pathophysiology of keloids which remain a therapeutic challenge. (author)

  15. 18F-FDG-PET/CT in staging, restaging, and treatment response assessment of male breast cancer

    International Nuclear Information System (INIS)

    Groheux, David; Hindié, Elif; Marty, Michel; Espié, Marc; Rubello, Domenico; Vercellino, Laetitia; Bousquet, Guilhem; Ohnona, Jessica; Toubert, Marie-Elisabeth; Merlet, Pascal; Misset, Jean-Louis

    2014-01-01

    Purpose: Male breast cancer (BC) is a rare disease, with patterns different from those found in women. Most tumors are detected at more advanced stages than in women. The aim of this study was to analyze the performance of [18F]fluorodeoxyglucose positron emission tomography/computed tomography ( 18 F-FDG-PET/CT) in staging, restaging, and therapy response assessment. Methods: We performed a systematic analysis in the database of Saint-Louis Hospital to identify male patients with BC referred for PET/CT. 18 F-FDG-PET/CT findings considered suspicious for malignancy were compared to biopsy results, further work-up and/or patient follow-up of at least 6 months. Performances of 18 F-FDG-PET/CT were compared to that of conventional imaging (CI) using the McNemar test. The impact of PET/CT on management was evaluated. Results: During 6 consecutive years, among 12,692 18 F-FDG-PET/CT oncology studies, 30 were performed in 15 men with BC: 7 examinations for initial staging, 11 for restaging, and 12 for response assessment. Tumors profile was ER+ and one had HER2 overexpression. PET/CT sensitivity, specificity, positive predictive value, negative predictive value and accuracy to detect distant metastases were 100%, 67%, 86%, 100% and 89%, respectively. PET/CT was more informative than CI in 40% of studies (p = 0.03; 95% confidence interval: 3.26 – 40%). Findings from 18 F-FDG-PET/CT led to modification in the planned treatment in 13/30 cases (43%). Conclusion: Although all the tumors were ER+, primary lesions and metastases were diagnosed with high sensitivity. 18 F-FDG-PET/CT seems to be a powerful imaging method to perform staging, restaging and treatment response assessment in male patients with BC

  16. Molecular Imaging Probes for Diagnosis and Therapy Evaluation of Breast Cancer

    Directory of Open Access Journals (Sweden)

    Qingqing Meng

    2013-01-01

    Full Text Available Breast cancer is a major cause of cancer death in women where early detection and accurate assessment of therapy response can improve clinical outcomes. Molecular imaging, which includes PET, SPECT, MRI, and optical modalities, provides noninvasive means of detecting biological processes and molecular events in vivo. Molecular imaging has the potential to enhance our understanding of breast cancer biology and effects of drug action during both preclinical and clinical phases of drug development. This has led to the identification of many molecular imaging probes for key processes in breast cancer. Hormone receptors, growth factor receptor, and angiogenic factors, such as ER, PR, HER2, and VEGFR, have been adopted as imaging targets to detect and stage the breast cancer and to monitor the treatment efficacy. Receptor imaging probes are usually composed of targeting moiety attached to a signaling component such as a radionuclide that can be detected using dedicated instruments. Current molecular imaging probes involved in breast cancer diagnosis and therapy evaluation are reviewed, and future of molecular imaging for the preclinical and clinical is explained.

  17. Interpretation of digital breast tomosynthesis: preliminary study on comparison with picture archiving and communication system (PACS) and dedicated workstation.

    Science.gov (United States)

    Kim, Young Seon; Chang, Jung Min; Yi, Ann; Shin, Sung Ui; Lee, Myung Eun; Kim, Won Hwa; Cho, Nariya; Moon, Woo Kyung

    2017-08-01

    To compare the diagnostic accuracy and efficiency in the interpretation of digital breast tomosynthesis (DBT) images using a picture archiving and communication system (PACS) and a dedicated workstation. 97 DBT images obtained for screening or diagnostic purposes were stored in both a workstation and a PACS and evaluated in combination with digital mammography by three independent radiologists retrospectively. Breast Imaging-Reporting and Data System final assessments and likelihood of malignancy (%) were assigned and the interpretation time when using the workstation and PACS was recorded. Receiver operating characteristic curve analysis, sensitivities and specificities were compared with histopathological examination and follow-up data as a reference standard. Area under the receiver operating characteristic curve values for cancer detection (0.839 vs 0.815, p = 0.6375) and sensitivity (81.8% vs 75.8%, p = 0.2188) showed no statistically significant differences between the workstation and PACS. However, specificity was significantly higher when analysing on the workstation than when using PACS (83.7% vs 76.9%, p = 0.009). When evaluating DBT images using PACS, only one case was deemed necessary to be reanalysed using the workstation. The mean time to interpret DBT images on PACS (1.68 min/case) was significantly longer than that to interpret on the workstation (1.35 min/case) (p < 0.0001). Interpretation of DBT images using PACS showed comparable diagnostic performance to a dedicated workstation, even though it required a longer reading time. Advances in knowledge: Interpretation of DBT images using PACS is an alternative to evaluate the images when a dedicated workstation is not available.

  18. PET/MR Imaging in Gynecologic Oncology.

    Science.gov (United States)

    Ohliger, Michael A; Hope, Thomas A; Chapman, Jocelyn S; Chen, Lee-May; Behr, Spencer C; Poder, Liina

    2017-08-01

    MR imaging and PET using 2-Deoxy-2-[ 18 F]fluoroglucose (FDG) are both useful in the evaluation of gynecologic malignancies. MR imaging is superior for local staging of disease whereas fludeoxyglucose FDG PET is superior for detecting distant metastases. Integrated PET/MR imaging scanners have great promise for gynecologic malignancies by combining the advantages of each modality into a single scan. This article reviews the technology behind PET/MR imaging acquisitions and technical challenges relevant to imaging the pelvis. A dedicated PET/MR imaging protocol; the roles of PET and MR imaging in cervical, endometrial, and ovarian cancers; and future directions for PET/MR imaging are discussed. Copyright © 2017 Elsevier Inc. All rights reserved.

  19. HER2-positive breast cancer: {sup 18}F-FDG PET for early prediction of response to trastuzumab plus taxane-based neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Humbert, Olivier; Brunotte, Francois [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); CHU Le Bocage, Imaging Department, Dijon (France); Universite de Bourgogne, UMR CNRS 5158, Dijon (France); Cochet, Alexandre [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); Universite de Bourgogne, UMR CNRS 5158, Dijon (France); Riedinger, Jean-Marc [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); Centre GF Leclerc, Department of Biology and Pathology, Dijon (France); Berriolo-Riedinger, Alina; Toubeau, Michel; Dygai-Cochet, Inna [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); Arnould, Laurent [Centre GF Leclerc, Department of Biology and Pathology, Dijon (France); Coudert, Bruno; Desmoulins, Isabelle; Guiu, Severine; Fumoleau, Pierre [Centre GF Leclerc, Department of Medical Oncology, Dijon (France); Coutant, Charles [Centre GF Leclerc, Department of Surgery, Dijon (France)

    2014-08-15

    To investigate the value of {sup 18}F-fluorodeoxyglucose positron emission tomography ({sup 18}F-FDG PET/CT) to predict a pathological complete response (pCR) after neoadjuvant chemotherapy (NAC) in women with human epidermal growth factor receptor 2 (HER2)-positive breast cancer. Fifty-seven consecutive women with HER2-positive breast cancer, treated with trastuzumab plus taxane-based NAC, were prospectively included. Maximum Standardized Uptake Value of the primary tumor and axillary nodes were measured at baseline (PET{sub 1}.SUV{sub max}) and after the first course of NAC (PET{sub 2}.SUV{sub max}). Tumor metabolic volumes were assessed to determine Total Lesion Glycolysis (TLG). The tumor metabolic response (ΔSUV{sub max} and ΔTLG) was calculated. In univariate analysis, negative hormonal receptor status (p = 0.04), high tumor grade (p = 0.03), and low tumor PET{sub 2}.SUV{sub max} (p = 0.001) were predictive of pCR. Tumor ΔSUV{sub max} correlated with pCR (p = 0.03), provided that tumors with low metabolic activity at baseline were excluded. ΔTLG did not correlate with pCR. In multivariate analysis, tumor PET{sub 2}.SUV{sub max} < 2.1 was the best independent predictive factor (Odds ratio =14.3; p = 0.004) with both negative and positive predictive values of 76 %. Although the metabolic features of the primary tumor did not depend on hormonal receptor status, both the baseline metabolism and early response of axillary nodes were higher if estrogen receptors were not expressed (p = 0.01 and p = 0.03, respectively). In HER2-positive breast cancer, very low tumor residual metabolism after the first cycle of NAC (SUV{sub max} < 2.1) was the main predictor of pCR. These results should be further explored in multicenter studies and incorporated into the design of clinical trials. (orig.)

  20. Diagnostic PET Imaging of Mammary Microcalcifications Using 64Cu-DOTA-Alendronate in a Rat Model of Breast Cancer.

    Science.gov (United States)

    Ahrens, Bradley J; Li, Lin; Ciminera, Alexandra K; Chea, Junie; Poku, Erasmus; Bading, James R; Weist, Michael R; Miller, Marcia M; Colcher, David M; Shively, John E

    2017-09-01

    The development of improved breast cancer screening methods is hindered by a lack of cancer-specific imaging agents and effective small-animal models to test them. The purpose of this study was to evaluate 64 Cu-DOTA-alendronate as a mammary microcalcification-targeting PET imaging agent, using an ideal rat model. Our long-term goal is to develop 64 Cu-DOTA-alendronate for the detection and noninvasive differentiation of malignant versus benign breast tumors with PET. Methods: DOTA-alendronate was synthesized, radiolabeled with 64 Cu, and administered to normal or tumor-bearing aged, female, retired breeder Sprague-Dawley rats for PET imaging. Mammary tissues were subsequently labeled and imaged with light, confocal, and electron microscopy to verify microcalcification targeting specificity of DOTA-alendronate and elucidate the histologic and ultrastructural characteristics of the microcalcifications in different mammary tumor types. Tumor uptake, biodistribution, and dosimetry studies were performed to evaluate the efficacy and safety of 64 Cu-DOTA-alendronate. Results: 64 Cu-DOTA-alendronate was radiolabeled with a 98% yield. PET imaging using aged, female, retired breeder rats showed specific binding of 64 Cu-DOTA-alendronate in mammary glands and mammary tumors. The highest uptake of 64 Cu-DOTA-alendronate was in malignant tumors and the lowest uptake in benign tumors and normal mammary tissue. Confocal analysis with carboxyfluorescein-alendronate confirmed the microcalcification binding specificity of alendronate derivatives. Biodistribution studies revealed tissue alendronate concentrations peaking within the first hour, then decreasing over the next 48 h. Our dosimetric analysis demonstrated a 64 Cu effective dose within the acceptable range for clinical PET imaging agents and the potential for translation into human patients. Conclusion: 64 Cu-DOTA-alendronate is a promising PET imaging agent for the sensitive and specific detection of mammary tumors as

  1. A PET imaging system dedicated to mammography

    CERN Document Server

    Varela, J

    2007-01-01

    The imaging system Clear-PEM for positron emission mammography, under development within the framework of the Crystal Clear Collaboration at CERN, is presented. The detector is based on pixelized LYSO crystals optically coupled to avalanche photodiodes (APD) and readout by a fast low-noise electronic system. A dedicated digital trigger and data acquisition system is used for on-line selection of coincidence events with high efficiency, large bandwidth and negligible dead-time. The detector module performance was characterized in detail.

  2. The role of {sup 18}F-FDG PET/CT in evaluation of early response to neoadjuvant chemotherapy in patients with locally advanced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kumar, Amandeep; Seenu, Vathalaru; Mehta, Sada Nand [All India Institute of Medical Sciences, Department of Surgical disciplines, New Delhi (India); Kumar, Rakesh; Chawla, Madhavi; Malhotra, Arun [All India Institute of Medical Sciences, Department of Nuclear Medicine, New Delhi (India); Gupta, Sidharatha Datta [All India Institute of Medical Sciences, Department of Pathology, New Delhi (India)

    2009-06-15

    We evaluated the role of 18F-FDG PET/CT for the assessment of response after two cycles of neo-adjuvant chemotherapy (NACT) for breast cancer. Twenty-three women with locally advanced breast cancer were included in this study. Early response to NACT was evaluated after two cycles using clinical examination, CT, and 18F-FDG PET/CT. Final histopathology following surgery after six cycles of NACT served as reference. Baseline PET/CT demonstrated a total of 26 lesions in 23 patients. The size of the primary tumor ranged from 1.90 cm to 11.60 cm, and the maximum value of the standardized uptake value of FDG (SUVmax) ranged from 3.6 to 38.6 (mean, 11.7). Post-chemotherapy PET/CT examinations were done after two cycles of NACT. The size of the primary tumor on follow-up PET/CT examinations ranged from 0.0 cm to 7.6 cm, and SUVmax ranged from 0.0 to 12.0 (mean, 3.96). On clinical, CT, and PET/CT examinations, 50% reduction in the parameters was taken as the cutoff value to differentiate between responders and non-responders. Post-NACT PET/CT demonstrated that 16 patients were responders and 7 non-responders. Among 16 responders on PET/CT scan, 14 were true positive and 2 were false positive when compared with histopathology. Among seven non-responder patients, six were true negative, and one was false negative. The sensitivity, specificity, and accuracy of PET/CT in detecting responders were 93%, 75%, and 87%, respectively. In conclusion, 18F-FDG PET/CT can differentiate responders from non-responders with high accuracy after two cycles of NACT in patients with LABC. (orig.)

  3. First-in-human uPAR PET

    DEFF Research Database (Denmark)

    Persson, Morten; Skovgaard, Dorthe; Brandt-Larsen, Malene

    2015-01-01

    A first-in-human clinical trial with Positron Emission Tomography (PET) imaging of the urokinase-type plasminogen activator receptor (uPAR) in patients with breast, prostate and bladder cancer, is described. uPAR is expressed in many types of human cancers and the expression is predictive...... for targeted molecular imaging with PET. The safety, pharmacokinetic, biodistribution profile and radiation dosimetry after a single intravenous dose of (64)Cu-DOTA-AE105 were assessed by serial PET and computed tomography (CT) in 4 prostate, 3 breast and 3 bladder cancer patients. Safety assessment...... of invasion, metastasis and indicates poor prognosis. uPAR PET imaging therefore holds promise to be a new and innovative method for improved cancer diagnosis, staging and individual risk stratification. The uPAR specific peptide AE105 was conjugated to the macrocyclic chelator DOTA and labeled with (64)Cu...

  4. PET/MR in invasive ductal breast cancer: correlation between imaging markers and histological phenotype.

    Science.gov (United States)

    Catalano, Onofrio Antonio; Horn, Gary Lloyd; Signore, Alberto; Iannace, Carlo; Lepore, Maria; Vangel, Mark; Luongo, Angelo; Catalano, Marco; Lehman, Constance; Salvatore, Marco; Soricelli, Andrea; Catana, Ciprian; Mahmood, Umar; Rosen, Bruce Robert

    2017-03-28

    Differences in genetics and receptor expression (phenotypes) of invasive ductal breast cancer (IDC) impact on prognosis and treatment response. Immunohistochemistry (IHC), the most used technique for IDC phenotyping, has some limitations including its invasiveness. We explored the possibility of contrast-enhanced positron emission tomography magnetic resonance (CE-FDG PET/MR) to discriminate IDC phenotypes. 21 IDC patients with IHC assessment of oestrogen receptor (ER), progesterone receptor (PR), human epidermal growth factor-2 (HER2), and antigen Ki-67 (Ki67) underwent CE-FDG PET/MR. Magnetic resonance-perfusion biomarkers, apparent diffusion coefficient (ADC), and standard uptake value (SUV) were compared with IHC markers and phenotypes, using a Student's t-test and one-way ANOVA. ER/PR- tumours demonstrated higher Kep mean and SUV max than ER or PR+ tumours. HER2- tumours displayed higher ADC mean , Kep mean , and SUV max than HER2+tumours. Only ADC mean discriminated Ki67⩽14% tumours (lower ADC mean ) from Ki67>14% tumours. PET/MR biomarkers correlated with IHC phenotype in 13 out of 21 patients (62%; P=0.001). Positron emission tomography magnetic resonance might non-invasively help discriminate IDC phenotypes, helping to optimise individual therapy options.

  5. A meta-analysis of 18FDG-PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with breast cancer

    International Nuclear Information System (INIS)

    Liu, Tao; Yang, Hui-Lin; Cheng, Tao; Xu, Wen; Yan, Wei-Li; Liu, Jia

    2011-01-01

    To perform a meta-analysis comparing the diagnostic value of 18 FDG-PET, MRI, and bone scintigraphy (BS) in detecting bone metastases in patients with breast cancer. MEDLINE, EMBASE, Scopus, ScienceDirect, SpringerLink, Web of Knowledge, EBSCO, and the Cochrane Database of Systematic Review databases were searched for relevant original articles published from January 1995 to January 2010. Inclusion criteria was as follows: 18 FDG-PET, MRI or 99m Tc-MDP BS was performed to detect bone metastases (the number of published CT studies was inadequate for meta-analysis and therefore could not be included in this study); sufficient data were presented to construct a 2 x 2 contingency table; histopathological analysis and/or close clinical and imaging follow-up for at least 6 months were used as the reference standard. Two reviewers independently assessed potentially eligible studies and extracted relevant data. A software program called ''META-DiSc'' was used to obtain the pooled estimates for sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the *Q index for each modality. Thirteen articles consisting of 23 studies fulfilled all inclusion criteria. On a per-patient basis, the pooled sensitivity estimates for MRI (97.1%) were significantly higher than those for PET (83.3%) and BS (87.0%; P 0.05). The pooled DOR estimates for MRI (298.5) were significantly higher than those for PET (82.1%) and BS (49.3%; P 0.05). The SROC curve for MRI showed better diagnostic accuracy than those for PET and BS. The SROC curve for PET was better than that for BS. The*Q index for MRI (0.935), PET (0.922), and BS (0.872) showed no significant difference (P ≥0.05). On a per-lesion basis, the pooled sensitivity estimates for BS (87.8%) were significantly higher than those for PET (52.7%; P 18 FDG-PET and BS for diagnosis of bone metastases in patients with breast cancer on a per-patient basis. On a per-lesion basis, 18 FDG-PET

  6. {sup 18}F-FDG-PET/CT in staging, restaging, and treatment response assessment of male breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Groheux, David, E-mail: dgroheux@yahoo.fr [Department of Nuclear Medicine, Saint-Louis Hospital, Paris (France); Doctoral School of Biology and Biotechnology, University Institute of Hematology, University of Paris VII, Paris (France); Hindié, Elif [Department of Nuclear Medicine, Haut-Lévêque Hospital, CHU Bordeaux, University Bordeaux-Segalen, Bordeaux (France); Marty, Michel [Breast Diseases Unit and Department of Medical Oncology, Saint-Louis Hospital, Paris (France); Centre for Therapeutic Innovation, Saint-Louis Hospital, Paris (France); Espié, Marc [Breast Diseases Unit and Department of Medical Oncology, Saint-Louis Hospital, Paris (France); Rubello, Domenico [Department of Nuclear Medicine, Santa Maria della Misericordia, Rovigo Hospital, Rovigo (Italy); Vercellino, Laetitia [Department of Nuclear Medicine, Saint-Louis Hospital, Paris (France); Doctoral School of Biology and Biotechnology, University Institute of Hematology, University of Paris VII, Paris (France); Bousquet, Guilhem [Breast Diseases Unit and Department of Medical Oncology, Saint-Louis Hospital, Paris (France); INSERM U728, University Institute of Hematology, University of Paris VII, Paris (France); Ohnona, Jessica; Toubert, Marie-Elisabeth [Department of Nuclear Medicine, Saint-Louis Hospital, Paris (France); Merlet, Pascal [Department of Nuclear Medicine, Saint-Louis Hospital, Paris (France); Doctoral School of Biology and Biotechnology, University Institute of Hematology, University of Paris VII, Paris (France); Misset, Jean-Louis [Breast Diseases Unit and Department of Medical Oncology, Saint-Louis Hospital, Paris (France)

    2014-10-15

    Purpose: Male breast cancer (BC) is a rare disease, with patterns different from those found in women. Most tumors are detected at more advanced stages than in women. The aim of this study was to analyze the performance of [18F]fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG-PET/CT) in staging, restaging, and therapy response assessment. Methods: We performed a systematic analysis in the database of Saint-Louis Hospital to identify male patients with BC referred for PET/CT. {sup 18}F-FDG-PET/CT findings considered suspicious for malignancy were compared to biopsy results, further work-up and/or patient follow-up of at least 6 months. Performances of {sup 18}F-FDG-PET/CT were compared to that of conventional imaging (CI) using the McNemar test. The impact of PET/CT on management was evaluated. Results: During 6 consecutive years, among 12,692 {sup 18}F-FDG-PET/CT oncology studies, 30 were performed in 15 men with BC: 7 examinations for initial staging, 11 for restaging, and 12 for response assessment. Tumors profile was ER+ and one had HER2 overexpression. PET/CT sensitivity, specificity, positive predictive value, negative predictive value and accuracy to detect distant metastases were 100%, 67%, 86%, 100% and 89%, respectively. PET/CT was more informative than CI in 40% of studies (p = 0.03; 95% confidence interval: 3.26 – 40%). Findings from {sup 18}F-FDG-PET/CT led to modification in the planned treatment in 13/30 cases (43%). Conclusion: Although all the tumors were ER+, primary lesions and metastases were diagnosed with high sensitivity. {sup 18}F-FDG-PET/CT seems to be a powerful imaging method to perform staging, restaging and treatment response assessment in male patients with BC.

  7. Combined PET/MRI

    DEFF Research Database (Denmark)

    Bailey, D. L.; Pichler, B. J.; Gückel, B.

    2015-01-01

    This paper summarises key themes and discussions from the 4th international workshop dedicated to the advancement of the technical, scientific and clinical applications of combined positron emission tomography (PET)/magnetic resonance imaging (MRI) systems that was held in Tübingen, Germany, from...

  8. Initial Results of a Prospective Clinical Trial of 18F-Fluciclovine PET/CT in Newly Diagnosed Invasive Ductal and Invasive Lobular Breast Cancers.

    Science.gov (United States)

    Ulaner, Gary A; Goldman, Debra A; Gönen, Mithat; Pham, Hanh; Castillo, Raychel; Lyashchenko, Serge K; Lewis, Jason S; Dang, Chau

    2016-09-01

    (18)F-labeled 1-amino-3-fluorocyclobutane-1-carboxylic acid ((18)F-fluciclovine) is a leucine analog PET/CT radiotracer that depicts amino acid transport into cells. Amino acid transport proteins have been shown to be upregulated in breast malignancies by microarray and immunohistochemical analysis, so we hypothesized that (18)F-fluciclovine may provide a novel method of visualizing breast cancer and now report a prospective clinical trial of (18)F-fluciclovine PET/CT in newly diagnosed advanced local invasive ductal carcinoma (IDC) and invasive lobular carcinoma (ILC). Twenty-seven women with a new diagnosis of locally advanced IDC (n = 19) or ILC (n = 8) underwent PET/CT of the chest after intravenous administration of 370 MBq of (18)F-fluciclovine. The SUVmax, SUVmean, metabolic tumor volume, and total lesion avidity were obtained for the primary breast tumor, axillary lymph nodes, and extraaxillary lymph nodes. Sites of previously unsuspected malignancy were recorded and confirmed by pathology. Results of (18)F-fluciclovine PET/CT were compared with those of (18)F-FDG PET/CT, when available, using the concordance correlation coefficient. All locally advanced breast cancers were (18)F-fluciclovine-avid. Of 21 patients with pathologically proven axillary nodal metastases, (18)F-fluciclovine-avid axillary nodes were seen in 20. (18)F-fluciclovine detected pathologically proven extraaxillary nodal metastases in 3 patients, including 2 previously unsuspected internal mammary nodes. Fourteen patients underwent (18)F-FDG PET/CT for comparison with (18)F-fluciclovine. Concordance for metabolic tumor volume between (18)F-fluciclovine and (18)F-FDG was strong (concordance correlation coefficient, 0.89; 95% confidence interval, 0.73-0.96), but concordance for SUVmax was weak (concordance correlation coefficient, 0.04; 95% confidence interval, -0.16-0.24). In patients with both modalities available (n = 14), primary ILCs (n = 4) demonstrated (18)F-fluciclovine avidity

  9. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    Energy Technology Data Exchange (ETDEWEB)

    Hernandez, A [Department of Radiology, Biomedical Engineering Graduate Group, University of California Davis, Sacramento, CA (United States); Boone, J [Departments of Radiology and Biomedical Engineering, University of California Davis, Sacramento, CA (United States)

    2016-06-15

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  10. WE-DE-207B-11: Implementation of Size-Specific 3D Beam Modulation Filters On a Dedicated Breast CT Platform Using Breast Immobilization

    International Nuclear Information System (INIS)

    Hernandez, A; Boone, J

    2016-01-01

    Purpose: To implement a 3D beam modulation filter (3D-BMF) in dedicated breast CT (bCT) and develop a method for conforming the patient’s breast to a pre-defined shape, optimizing the effects of the filter. This work expands on previous work reporting the methodology for designing a 3D-BMF that can spare unnecessary dose and improve signal equalization at the detector by preferentially filtering the beam in the thinner anterior and peripheral breast regions. Methods: Effective diameter profiles were measured for 219 segmented bCT images, grouped into volume quintiles, and averaged within each group to represent the range of breast sizes found clinically. These profiles were then used to generate five size-specific computational phantoms and fabricate five size-specific UHMW phantoms. Each computational phantom was utilized for designing a size-specific 3D-BMF using previously reported methods. Glandular dose values and projection images were simulated in MCNP6 with and without the 3DBMF using the system specifications of our prototype bCT scanner “Doheny”. Lastly, thermoplastic was molded around each of the five phantom sizes and used to produce a series of breast immobilizers for use in conforming the patient’s breast during bCT acquisition. Results: After incorporating the 3D-BMF, MC simulations estimated an 80% average reduction in the detector dynamic range requirements across all phantom sizes. The glandular dose was reduced on average 57% after normalizing by the number of quanta reaching the detector under the thickest region of the breast. Conclusion: A series of bCT-derived breast phantoms were used to design size-specific 3D-BMFs and breast immobilizers that can be used on the bCT platform to conform the patient’s breast and therefore optimally exploit the benefits of the 3D-BMF. Current efforts are focused on fabricating several prototype 3D-BMFs and performing phantom scans on Doheny for MC simulation validation and image quality analysis

  11. Detection of bone metastases in breast cancer patients in the PET/CT era: Do we still need the bone scan?

    Science.gov (United States)

    Caglar, M; Kupik, O; Karabulut, E; Høilund-Carlsen, P F

    2016-01-01

    To examine the value of 18F-fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) for the detection of bone metastasis in breast cancer patients and assess whether whole body bone scan (BS) with (99m)Tc-methylene diphosphonate provides any additional information. Study group comprised 150 patients, mean age 52 years (range 27-85) with breast cancer, suspected of having bone metastases. All patients had undergone both FDG-PET/CT and BS with or without single photon emission tomography/computed tomography (SPECT/CT) within a period of 6 weeks. The final diagnosis of bone metastasis was established by histopathological findings, additional imaging, or clinical follow-up longer than 10 months. Cancer antigen 15-3 (CA15-3) and carcinoembryogenic antigen (CEA) were measured in all patients. Histologically 83%, 7% and 10% had infiltrating ductal, lobular and mixed carcinoma respectively. Confirmed bone metastases were present in 86 patients (57.3%) and absent in 64 (42.7%). Mean CA15-3 and CEA values in patients with bone metastases were 74.6ng/mL and 60.4U/mL respectively, compared to 21.3ng/mL and 3.2U/mL without metastases (p<0.001). The sensitivity of FDG-PET/CT for the detection of bone metastases was 97.6% compared to 89.5% with SPECT/CT. In 57 patients, FDG-PET/CT correctly identified additional pulmonary, hepatic, nodal and other soft tissue metastases, not detected by BS. Our findings suggest that FDG-PET/CT is superior to BS with or without SPECT/CT. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  12. TU-F-18C-07: Hardware Advances for MTF Improvement in Dedicated Breast CT

    International Nuclear Information System (INIS)

    Gazi, P; Burkett, G; Yang, K; Boone, J

    2014-01-01

    Purpose: In this study, we have designed and implemented a prototype dedicated breast CT system (bCT) to improve the spatial resolution characteristics, in order to improve detection of micro-calcifications. Methods: A 10.8 kW water-cooled, tungsten anode x-ray tube, running up to 240 mA at 60 kV, coupled with an x-ray generator specifically designed for this application, and 0.3 mm of added copper filter was used to generate x-ray pulses. A CsI CMOS flat panel detector with a pixel pitch of 0.075 mm in native binning mode was used. The system geometry was designed in a way to achieve an FOV on par with similar bCT prototypes, resulting in a magnification factor of 1.39. A 0.013 mm tungsten wire was used to generate point spread functions. Multiple scans were performed with different numbers of projections, different reconstruction kernel sizes and different reconstruction filters to study the effects of each parameter on MTF. The resulting MTFs were then evaluated quantitatively using the generated PFSs. Duplicate scans with the same parameters were performed on two other dedicated breast CT systems to compare the performance of the new prototype. Results: The results of the MTF experiments demonstrate a significant improvement in the spatial resolution characteristics. In the new prototype, using the pulsed x-ray source results in a restoration of the azimuthal MTF degradation, due to motion blurring previously seen in other bCT systems. Moreover, employing the higher resolution x-ray detector considerably improves the MTF. The MTF at 10% of the new system is at 3.5 1/mm, a factor of 4.36 greater than an earlier bCT scanner. Conclusion: The MTF analysis of the new prototype bCT shows that using the new hardware and control results in a significant improvement in visualization of finer detail. This suggests that the visualization of micro-calcifications will be significantly improved

  13. Spatial resolution recovery utilizing multi-ray tracing and graphic processing unit in PET image reconstruction

    International Nuclear Information System (INIS)

    Liang, Yicheng; Peng, Hao

    2015-01-01

    Depth-of-interaction (DOI) poses a major challenge for a PET system to achieve uniform spatial resolution across the field-of-view, particularly for small animal and organ-dedicated PET systems. In this work, we implemented an analytical method to model system matrix for resolution recovery, which was then incorporated in PET image reconstruction on a graphical processing unit platform, due to its parallel processing capacity. The method utilizes the concepts of virtual DOI layers and multi-ray tracing to calculate the coincidence detection response function for a given line-of-response. The accuracy of the proposed method was validated for a small-bore PET insert to be used for simultaneous PET/MR breast imaging. In addition, the performance comparisons were studied among the following three cases: 1) no physical DOI and no resolution modeling; 2) two physical DOI layers and no resolution modeling; and 3) no physical DOI design but with a different number of virtual DOI layers. The image quality was quantitatively evaluated in terms of spatial resolution (full-width-half-maximum and position offset), contrast recovery coefficient and noise. The results indicate that the proposed method has the potential to be used as an alternative to other physical DOI designs and achieve comparable imaging performances, while reducing detector/system design cost and complexity. (paper)

  14. 68Ga-PSMA and 11C-Choline comparison using a tri-modality PET/CT-MRI (3.0 T) system with a dedicated shuttle.

    Science.gov (United States)

    Alonso, Omar; Dos Santos, Gerardo; García Fontes, Margarita; Balter, Henia; Engler, Henry

    2018-01-01

    The aim of this study was to prospectively compare the detection rate of 68 Ga-PSMA versus 11 C-Choline in men with prostate cancer with biochemical recurrence and to demonstrate the added value of a tri-modality PET/CT-MRI system. We analysed 36 patients who underwent both 11 C-Choline PET/CT and 68 Ga-PSMA PET/CT scanning within a time window of 1-2 weeks. Additionally, for the 68 Ga-PSMA scan, we used a PET/CT-MRI (3.0 T) system with a dedicated shuttle, acquiring MRI images of the pelvis. Both scans were positive in 18 patients (50%) and negative in 8 patients (22%). Nine patients were positive with 68 Ga-PSMA alone (25%) and one with 11 C-Choline only (3%). The median detected lesion per patient was 2 for 68 Ga-PSMA (range 0-93) and 1 for 11 C-Choline (range 0-57). Tumour to background ratios in all concordant lesions ( n  = 96) were higher for 68 Ga-PSMA than for 11 C-Choline (110.3 ± 107.8 and 27.5 ± 17.1, mean ± S.D., for each tracer, respectively P  = 0.0001). The number of detected lesions per patient was higher for 11 C-Choline in those with PSA ≥ 3.3 ng/mL, while the number of detected lesions was independent of PSA levels for 68 Ga-PSMA using the same PSA cut-off value. Metastatic pelvic lesions were found in 25 patients (69%) with 68 Ga-PSMA PET/CT, in 18 (50%) with 11 C-Choline PET/CT and in 21 (58%) with MRI (3.0 T). MRI was very useful in detecting recurrence in cases classified as indeterminate by means of PET/CT alone at prostate bed. In patients with prostate cancer with biochemical recurrence 68 Ga-PSMA detected more lesions per patient than 11 C-Choline, regardless of PSA levels. PET/CT-MRI (3.0 T) system is a feasible imaging modality that potentially adds useful relevant information with increased accuracy of diagnosis.

  15. 18F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    International Nuclear Information System (INIS)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P.; Lerebours, F.; Fourme, E.; Le Stanc, E.; Cherel, P.; Alberini, J.L.

    2009-01-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 ± 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max)≥5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  16. N-(n-benzylpiperidin-4-yl)-2-[18f]fluorobenzamide: a potential ligand for PET imaging of breast cancer

    International Nuclear Information System (INIS)

    Shiue, Chyng-Yann; Shiue, Grace G.; Benard, Francois; Visonneau, Sophie; Santoli, Daniela; Alavi, Abass A.

    2000-01-01

    N-(N-Benzylpiperidin-4-yl)-2-[ 18 F]fluorobenzamide (2), a potential ligand for PET imaging of sigma receptor, has been found to be a potential agent for detection of breast cancer. In vivo studies in severe combined immunodeficient (SCID) mice bearing MDA-MB231 tumors showed that the uptake of compound 2 in these tumors was high (3.8%/g); the ratios of tumor/muscle and tumor/blood were 6.2 and 7.0, respectively, at 1 h postinjection. Pretreatment of SCID mice with haldol increased the uptake of compound 2 in blood, muscle, and other well-perfused organs while decreasing its uptake in tumors. The ratios of tumor/muscle and tumor/blood decreased from 6.2 and 7.0 to 1.3 and 1.1, respectively, at 1 h postinjection. At 2 h postinjection, the ratios of tumor/muscle and tumor/blood decreased from 4.9 and 7.8 to 1.4 and 1.4, respectively. The tumor uptake of compound 2 in SCID mice bearing primary tumor explants from a human breast cancer patient was lower than that in MDA-MB231 tumors (1.66%/g versus 3.78%/g), and the ratios of tumor/muscle and tumor/blood were 3.5 and 3.7, respectively, at 1 h postinjection. These results suggest that compound 2 may be a potential ligand for PET imaging of breast cancer

  17. An Austrian framework for PET quality control

    International Nuclear Information System (INIS)

    Nicoletti, R.; Dobrozemsky, G.; Minear, G.; Bergmann, H.

    2002-01-01

    Full text: The European patient protection directive (97/43 EURATOM) requires regular routine quality control (QC) of PET imaging devices. Since no standards were available covering this area and in order to comply with the directive a joint working party of the Austrian societies of nuclear medicine and of medical physics have developed a set of procedures suitable for both dedicated PET scanners and gamma cameras operating in coincidence mode (GCPET). The routine procedures proposed include both manufacturer recommended procedures and tests for specific parameters and calibration procedures. Wherever possible, procedures adapted or derived from NEMA standards publication NU 2-2001 were used to permit direct comparison with specified parameters of image quality. For dedicated PET scanners the most important procedures are the checking of detector sensitivities and the attenuation calibration scan. With full ring scanners the attenuation calibration scan is a blank scan, with partial ring devices a special attenuation calibration phantom has to be used. Test protocols are specific to manufacturer and scanner type. They are usually performed automatically overnight. In addition, some instruments require special calibrations, e.g. gain adjustments or coincidence timing calibration. GCPET procedures include the frequent assessment in coincidence mode of detector uniformity, energy resolution and system sensitivity. Common to both dedicated PET and GCPET are the regular quarterly assessment of tomographic spatial resolution and the calibration of the system for quantitative measurements. As a total performance test for both systems assessment of image quality following NU 2-2001 was included, to be carried out after major system changes or repairs. The suite of QC procedures was tested on several dedicated PET and GCPET systems including all major manufacturers' systems. Due to missing hardware or software not all tests could be performed on all systems. Some of the

  18. A novel semi-robotized device for high-precision 18F-FDG-guided breast cancer biopsy.

    Science.gov (United States)

    Hellingman, D; Teixeira, S C; Donswijk, M L; Rijkhorst, E J; Moliner, L; Alamo, J; Loo, C E; Valdés Olmos, R A; Stokkel, M P M

    To assess the 3D geometric sampling accuracy of a new PET-guided system for breast cancer biopsy (BCB) from areas within the tumour with high 18 F-FDG uptake. In the context of the European Union project MammoCare, a prototype semi-robotic stereotactic prototype BCB-device was incorporated into a dedicated high resolution PET-detector for breast imaging. The system consists of 2 stacked rings, each containing 12 plane detectors, forming a dodecagon with a 186mm aperture for 3D reconstruction (1mm 3 voxel). A vacuum-assisted biopsy needle attached to a robot-controlled arm was used. To test the accuracy of needle placement, the needle tip was labelled with 18 F-FDG and positioned at 78 target coordinates distributed over a 35mm×24mm×28mm volume within the PET-detector field-of-view. At each position images were acquired from which the needle positioning accuracy was calculated. Additionally, phantom-based biopsy proofs, as well as MammoCare images of 5 breast cancer patients, were evaluated for the 3D automated locating of 18 F-FDG uptake areas within the tumour. Needle positioning tests revealed an average accuracy of 0.5mm (range 0-1mm), 0.6mm (range 0-2mm), and 0.4mm (range 0-2mm) for the x/y/z-axes, respectively. Furthermore, the MammoCare system was able to visualize and locate small (cancer core needle biopsy. Its clinical feasibility evaluation in breast cancer patients scheduled for neo-adjuvant chemotherapy will follow. Copyright © 2016 Elsevier España, S.L.U. y SEMNIM. All rights reserved.

  19. Primary Rectal Adenocarcinoma Metastasizing to Bilateral Breast - a Rare Case Demonstrated by {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Soundararajan, Ramya; Arora, Saurabh; Das, Chandan Jyoti; Roy, Maitrayee; Kumar, Rakesh; Bal, Chandrasekhar [All India Institute of Medical Sciences, New Delhi (India)

    2016-06-15

    A 22-year-old female presented with multiple painless bilateral breast masses for the past 2 months. On Further questioning she had hematochezia and constipation for three months. On digital rectal examination, thickening of rectal mucosa at 5 cm from the anal verge was found. On physical examination, multiple firm, non-tender, nodular lesions were found in bilateral breasts. Metastatic breast disease from extra mammary primaries is uncommon and it constitutes 0.5 - 6% of all breast malignancies. melanomas, lymphomas, leukemias, ands sarcomas are the most common malignancies causing breast metastases. Infrequently, carcinomas of the lung, stomach, ovary, liver, tonsil, pleura, pancreas, cervix, perineum, endometrium, bladder, carcinoid tumors and renal cell carcinomas can cause metastatic breast disease. Metastatic breast disease from colorectal cancer is characterised by disseminated metastatic disease and a poor prognosis. In this case, It was essential to distinguish between metastatic breast disease primary breast carcinoma to plan appropriate management. Because of its rare incidence and high index of clinical suspicion, appropriate radiological investigations and histopathology is essential for accurate diagnosis. {sup 18}F-FDG PET/CT, being a whole-body metabolic functional imaging modality, helped us determine the extent of the primary and metastatic disease. In view of disseminated metastases, the bilateral breast disease was also considered as metastatic involvement, Which was proven by histopathology.

  20. Early and delayed prediction of axillary lymph node neoadjuvant response by {sup 18}F-FDG PET/CT in patients with locally advanced breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Garcia Vicente, Ana Maria; Soriano Castrejon, Angel; Jimenez Londono, German Andres [University General Hospital, Nuclear Medicine Department, Ciudad Real (Spain); Leon Martin, Alberto [University General Hospital, Investigation Unit, Ciudad Real (Spain); Relea Calatayud, Fernanda [University General Hospital, Pathology Department, Ciudad Real (Spain); Munoz Sanchez, Maria del Mar [Virgen de la Luz Hospital, Oncology Department, Cuenca (Spain); Cruz Mora, Miguel Angel [Virgen de la Salud Hospital, Oncology Department, Toledo (Spain); Espinosa Aunion, Ruth [La Mancha Centro Hospital, Oncology Department, Ciudad Real (Spain)

    2014-07-15

    To determine the utility of {sup 18}F-FDG (FDG) PET/CT performed in an early and delayed phase during neoadjuvant chemotherapy in the prediction of lymph node histopathological response in patients with locally advanced breast cancer. FDG PET/CT studies performed in 76 patients (mean age 53 years) at baseline (PET-1), after the second course of chemotherapy (PET-2) and after the last course of chemotherapy (PET-3) were prospectively analysed. Inclusion criteria were lymph node involvement detected by PET/CT and non-sentinel node biopsy before or after the baseline PET/CT scan. Following the recommendations of the 12th International Breast Conference (St. Gallen), the patients were divided into five subgroups in relation to biological prognostic factors by immunohistochemistry. For diagnosis visual and semiquantitative analyses was performed. Absence of detectable lymph node uptake on the PET-2 or PET-3 scan with respect to the PET-1 scan was considered metabolic complete response (mCR). Lymph nodes were histopathologically classified according the lymph node regression grade and in response groups as pathological complete response (pCR) or not pCR (type A/D or B/C of the Smith grading system, respectively). ROC analysis was performed to determine a cut-off value of Δ% SUV1-2 and SUV1-3 for prediction of nodal status after chemotherapy. An association between mCR and pCR was found (Cohen's kappa analysis), and associations between phenotypes and metabolic behaviour and the final histopathological status were also found. Lymph node pCR was seen in 34 patients. The sensitivity, specificity, and positive and negative predictive values of PET-2 and PET-3 in establishing the final status of the axilla after chemotherapy were 52 %, 45 %, 50 % and 47 %, and 33 %, 84 %, 67 % and 56 %, respectively. No significant relationship was observed between mCR on PET-2 and PET-3 and pCR (p = 0.31 and 0.99, respectively). Lymph node metabolism on PET-1 was not able to predict

  1. Prospective study of serial 18F-FDG PET and 18F-fluoride (18F-NaF) PET to predict time to skeletal related events, time-to-progression, and survival in patients with bone-dominant metastatic breast cancer.

    Science.gov (United States)

    Peterson, Lanell M; O'Sullivan, Janet; Wu, Qian Vicky; Novakova-Jiresova, Alena; Jenkins, Isaac; Lee, Jean H; Shields, Andrew; Montgomery, Susan; Linden, Hannah M; Gralow, Julie R; Gadi, Vijayakrishna K; Muzi, Mark; Kinahan, Paul E; Mankoff, David A; Specht, Jennifer M

    2018-05-10

    Assessing therapy response of breast cancer bone metastases is challenging. In retrospective studies, serial 18 F-FDG PET was predictive of time to skeletal related events (tSRE) and time-to-progression (TTP). 18 F-NaF PET improves bone metastasis detection compared to bone scans. We prospectively tested 18 F-FDG PET and 18 F-NaF PET to predict tSRE, TTP, and overall survival (OS) in patients with bone-dominant metastatic breast cancer (BD MBC). Methods: Patients with BD MBC were imaged with 18 F-FDG PET and 18 F-NaF PET prior to starting new therapy (scan1) and again at a range of times centered around approximately 4 months later (scan2). SUV max and SULpeak were recorded for a single index lesion and up to 5 most dominant lesions for each scan. tSRE, TTP, and OS were assessed exclusive of the PET images. Univariate Cox regression was performed to test the association between clinical endpoints and 18 F-FDG PET and 18 F-NaF PET measures. mPERCIST (Modified PET Response Criteria in Solid Tumors) criteria were also applied. Survival curves for mPERCIST compared response categories of Complete Response+Partial Response+Stable Disease versus Progressive Disease (CR+PR+SD vs PD) for tSRE, TTP, and OS. Results: Twenty-eight patients were evaluated. Higher FDG SULpeak at scan2 predicted shorter time to tSRE ( P = PET mPERCIST, tSRE and TTP were longer in responders (CR, PR, or stable) compared to non-responders (PD) ( P = 0.007, 0.028 respectively), with a trend toward improved survival ( P = 0.1). An increase in the uptake between scans of up to 5 lesions by 18 F-NaF PET was associated with longer OS ( P = 0.027). Conclusion: Changes in 18 F-FDG PET parameters during therapy are predictive of tSRE and TTP, but not OS. mPERCIST evaluation in bone lesions may be useful in assessing response to therapy and is worthy of evaluation in multicenter, prospective trials. Serial 18 F-NaF PET was associated with OS, but was not useful for predicting TTP or tSRE in BD MBC

  2. Analysis of the initial experience with first PET scanner and in Chile

    International Nuclear Information System (INIS)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo

    2005-01-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  3. Analysis of the initial experience with first PET scanner and in Chile

    Energy Technology Data Exchange (ETDEWEB)

    Massardo, Teresa; Jofre, Maria Josefina; Canessa, Jose; Gonzalez, Patricio; Humeres, Pamela; Sierralta, Paulina; Valdebenito, Robert; Galaz, Rodrigo [Centro PET de Imagenes Moleculares, Hospital Militar da Santiago, Santiago (Chile)

    2005-07-01

    The main application of positron emission tomography (PET) with Fluorine 18- deoxyglucose (FDG) is in the management of cancer patients due to the high correlation between cellular glucidic activity and malignancy. Objective: To analyze the initial group of cases performed with the first dedicated PET scanner in Chile. Method: We present the first 500 patients studied with a Siemens HR+ system using FDG produced at the Chilean Atomic Energy Commission facilities. Results: Most of the referrals were from oncology (96%). Four percent were studied due to neurological or psychiatric disorders and only 1% for myocardial viability. Lung lesions, gastrointestinal and breast carcinomas, melanoma and lymphoma corresponded to the most frequent diagnosis. Lung and lymphoma patients had clinical follow-up. There was good concordance with anatomical images and histology in those cases with available data. Fusion of FDG images with computed tomography or magnetic resonance was helpful. In a significant number of patients new tumoral sites were detected Conclusion: We confirm that in clinical practice, metabolic imaging with F18-FDG is helpful for cancer evaluation and management (au)

  4. Textural features and SUV-based variables assessed by dual time point 18F-FDG PET/CT in locally advanced breast cancer.

    Science.gov (United States)

    Garcia-Vicente, Ana María; Molina, David; Pérez-Beteta, Julián; Amo-Salas, Mariano; Martínez-González, Alicia; Bueno, Gloria; Tello-Galán, María Jesús; Soriano-Castrejón, Ángel

    2017-12-01

    To study the influence of dual time point 18F-FDG PET/CT in textural features and SUV-based variables and their relation among them. Fifty-six patients with locally advanced breast cancer (LABC) were prospectively included. All of them underwent a standard 18F-FDG PET/CT (PET-1) and a delayed acquisition (PET-2). After segmentation, SUV variables (SUVmax, SUVmean, and SUVpeak), metabolic tumor volume (MTV), and total lesion glycolysis (TLG) were obtained. Eighteen three-dimensional (3D) textural measures were computed including: run-length matrices (RLM) features, co-occurrence matrices (CM) features, and energies. Differences between all PET-derived variables obtained in PET-1 and PET-2 were studied. Significant differences were found between the SUV-based parameters and MTV obtained in the dual time point PET/CT, with higher values of SUV-based variables and lower MTV in the PET-2 with respect to the PET-1. In relation with the textural parameters obtained in dual time point acquisition, significant differences were found for the short run emphasis, low gray-level run emphasis, short run high gray-level emphasis, run percentage, long run emphasis, gray-level non-uniformity, homogeneity, and dissimilarity. Textural variables showed relations with MTV and TLG. Significant differences of textural features were found in dual time point 18F-FDG PET/CT. Thus, a dynamic behavior of metabolic characteristics should be expected, with higher heterogeneity in delayed PET acquisition compared with the standard PET. A greater heterogeneity was found in bigger tumors.

  5. Multicenter study for the evaluation of a dedicated biopsy device for MR-guided vacuum biopsy of the breast

    International Nuclear Information System (INIS)

    Perlet, C.; Sittek, H.; Schneider, P.; Reiser, M.; Heinig, A.; Stets, C.; Heywang-Koebrunner, S.H.; Prat, X.; Lamarque, J.; Taourel, P.; Casselman, J.; Baath, L.; Anderson, I.

    2002-01-01

    The purpose of this multicenter study was to determine the accuracy and clinical value of a dedicated breast biopsy system which allows for MR-guided vacuum biopsy (VB) of contrast-enhancing lesions. In five European centers, MR-guided 11-gauge VB was performed on 341 lesions. In 7 cases VB was unsuccessful. This was immediately realized on postinterventional images or direct follow-up combined with histopathology-imaging correlation; thus, a false-negative diagnosis was avoided. Histology of 334 successful biopsies yielded 84 (25%) malignancies, 17 (5%) atypical ductal hyperplasias, and 233 (70%) benign entities. Verification of malignant or borderline lesions included reexcision of the biopsy cavity. Benign histologic biopsy results were verified by retrospective correlation with the pre- and postinterventional MRI and by subsequent follow-up. Our results indicate that MR-guided VB, in combination with the dedicated biopsy coil, offers the possibility to accurately diagnose even very small lesions that can only be visualized or localized by MRI. (orig.)

  6. A virtual clinical trial comparing static versus dynamic PET imaging in measuring response to breast cancer therapy

    Science.gov (United States)

    Wangerin, Kristen A.; Muzi, Mark; Peterson, Lanell M.; Linden, Hannah M.; Novakova, Alena; Mankoff, David A.; E Kinahan, Paul

    2017-05-01

    We developed a method to evaluate variations in the PET imaging process in order to characterize the relative ability of static and dynamic metrics to measure breast cancer response to therapy in a clinical trial setting. We performed a virtual clinical trial by generating 540 independent and identically distributed PET imaging study realizations for each of 22 original dynamic fluorodeoxyglucose (18F-FDG) breast cancer patient studies pre- and post-therapy. Each noise realization accounted for known sources of uncertainty in the imaging process, such as biological variability and SUV uptake time. Four definitions of SUV were analyzed, which were SUVmax, SUVmean, SUVpeak, and SUV50%. We performed a ROC analysis on the resulting SUV and kinetic parameter uncertainty distributions to assess the impact of the variability on the measurement capabilities of each metric. The kinetic macro parameter, K i , showed more variability than SUV (mean CV K i   =  17%, SUV  =  13%), but K i pre- and post-therapy distributions also showed increased separation compared to the SUV pre- and post-therapy distributions (mean normalized difference K i   =  0.54, SUV  =  0.27). For the patients who did not show perfect separation between the pre- and post-therapy parameter uncertainty distributions (ROC AUC  dynamic imaging outperformed SUV in distinguishing metabolic change in response to therapy, ranging from 12 to 14 of 16 patients over all SUV definitions and uptake time scenarios (p  PET imaging.

  7. AX-PET: A novel PET concept with G-APD readout

    CERN Document Server

    Heller, M; Casella, C; Chesi, E; De Leo, R; Dissertori, G; Fanti, V; Gillam, J E; Joram, C; Lustermann, W; Nappi, E; Oliver, J F; Pauss, F; Rafecas, M; Rudge, A; Ruotsalainen, U; Schinzel, D; Schneider, T; Seguinot, J; Solevi, P; Stapnes, S; Tuna, U; Weilhammer, P

    2012-01-01

    The AX-PET collaboration has developed a novel concept for high resolution PET imaging to overcome some of the performance limitations of classical PET cameras, in particular the compromise between spatial resolution and sensitivity introduced by the parallax error. The detector consists of an arrangement of long LYSO scintillating crystals axially oriented around the field of view together with arrays of wave length shifter strips orthogonal to the crystals. This matrix allows a precise 3D measurement of the photon interaction point. This is valid both for photoelectric absorption at 511 key and for Compton scattering down to deposited energies of about 100 keV. Crystals and WLS strips are individually read out using Geiger-mode Avalanche Photo Diodes (G-APDs). The sensitivity of such a detector can be adjusted by changing the number of layers and the resolution is defined by the crystal and strip dimensions. Two AX-PET modules were built and fully characterized in dedicated test set-ups at CERN, with point-...

  8. Effects of reflector and crystal surface on the performance of a depth-encoding PET detector with dual-ended readout

    International Nuclear Information System (INIS)

    Ren, Silin; Yang, Yongfeng; Cherry, Simon R.

    2014-01-01

    Purpose: Depth encoding detectors are required to improve the spatial resolution and spatial resolution uniformity of small animal positron emission tomography (PET) scanners, as well as dedicated breast and brain scanners. Depth of interaction (DOI) can be measured by using dual-ended readout of lutetium oxyorthosilicate (LSO) scintillator arrays with position-sensitive avalanche photodiodes. Inter-crystal reflectors and crystal surface treatments play important roles in determining the performance of dual-ended detectors. In this paper, the authors evaluated five LSO arrays made with three different intercrystal reflectors and with either polished or unpolished crystal surfaces. Methods: The crystal size in all arrays was 1.5 mm, which is typical of the detector size used in small animal and dedicated breast scanners. The LSO arrays were measured with dual-ended readout and were compared in terms of flood histogram, energy resolution, and DOI resolution performance. Results: The four arrays using enhanced specular reflector (ESR) and Toray reflector provided similar quality flood histograms and the array using Crystal Wrap reflector gave the worst flood histogram. The two arrays using ESR reflector provided the best energy resolution and the array using Crystal Wrap reflector yielded the worst energy resolution. All arrays except the polished ESR array provided good DOI resolution ranging from 1.9 mm to 2.9 mm. DOI resolution improved as the gradient in light collection efficiency with depth (GLCED) increased. The geometric mean energies were also calculated for these dual-ended readout detectors as an alternative to the conventional summed total energy. It was shown that the geometric mean energy is advantageous in that it provides more uniform photopeak amplitude at different depths for arrays with high GLCED, and is beneficial in event selection by allowing a fixed energy window independent of depth. A new method of DOI calculation that improved the linearity

  9. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT) in combination with ultrasonography for axillary staging in primary breast cancer

    International Nuclear Information System (INIS)

    Ueda, Shigeto; Ishida, Jiro; Abe, Yoshiyuki; Mochizuki, Hidetaka; Tsuda, Hitoshi; Asakawa, Hideki; Omata, Jiro; Fukatsu, Kazuhiko; Kondo, Nobuo; Kondo, Tadaharu; Hama, Yukihiro; Tamura, Katsumi

    2008-01-01

    Accurate evaluation of axillary lymph node (ALN) involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18 F-fluorodeoxyglucose ( 18 F-FDG PET/CT) and axillary ultrasonography (AUS) for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18 F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB) and preoperative systemic chemotherapy (PSC). One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18 F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND). Using 18 F-FDG PET/CT, we studied both a visual assessment of 18 F-FDG uptake and standardized uptake value (SUV) for axillary staging. In a visual assessment of 18 F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18 F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18 F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12) in 18 F-FDG PET uptake only, 80% (4 of 5) in AUS positive only, and 100% (28 of 28) in dual positive. By the combination of AUS and 18 F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18 F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03). The diagnostic accuracy of 18 F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their limited sensitivities, the high radiation

  10. Cost-Effectiveness of 18f-Fdg Pet/Ct for Screening Distant Metastasis in Stage Ii/Iii Breast Cancer Patients of the UK, the United States and the Netherlands

    NARCIS (Netherlands)

    Miquel-Cases, A.; Da Silva Teixeira, Sandra; Retel, Valesca; Retel, V.P.; Steuten, Lotte Maria Gertruda; Valdes Olmos, R.; Rutgers, E.; van Harten, Willem H.

    2015-01-01

    Objectives: 18F-FDG-PET/CT is accurate in detecting distant metastases (DM) in breast cancer patients scheduled for neoadjuvant chemotherapy. If DMs are screen-detected in an early phase, morbidity and mortality may be reduced. Because 18F-FDG-PET/CT comes at a significant cost, we compared its

  11. {sup 18}F-Fluorodeoxyglucose Positron Emission Tomography/Computed Tomography (FDG-PET/CT) Imaging in the Staging and Prognosis of Inflammatory Breast Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Alberini, J.L.; Wartski, M.; Gontier, E.; Madar, O.; Pecking, A.P. [Nuclear Medicine Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Lerebours, F. [Oncology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Fourme, E. [Biostatistics Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Le Stanc, E. [Nuclear Medicine Department, Foch Hospital, Suresnes (France); Cherel, P. [Radiology Department, Cancer Research Center Rene Huguenin, Saint-Cloud (France); Alberini, J.L. [School of Medicine, Versailles Saint-Quentin University (France)

    2009-07-01

    Background: To prospectively assess fluorodeoxyglucose positron emission tomography/computed tomography (FDG-PET/CT) staging and prognosis value in patients with suspected inflammatory breast cancer (IBC). Methods: Sixty-two women (mean age 50.7 {+-} 11.4 years) presenting with unilateral inflammatory breast tumors (59 invasive carcinomas; 3 mastitis) underwent a PET/CT scan before biopsy. Results: PET/CT scan was positive for the primary malignant tumor in 100% and false positive in 2 of 3 benign mastitis. In 59 IBC patients, FDG nodal foci were detected in axillary (90%; n = 53) and extra-axillary areas (56%; n = 33) ipsilateral to the cancer. Compared with clinical examination, the axillary lymph node status by PET/CT was upstaged and down staged in 35 and 5 patients, respectively. In 7 of 9 N0 patients, the axillary lymph node positivity on PET/CT was correct, as revealed by pathological post surgery assessment (not available in the 2 remaining patients). The nodal foci were compared with preoperative fine needle aspiration and/or pathological post chemotherapy findings available in 44 patients and corresponded to 38 true positive, 4 false-negative, and 2 false-positive cases. In 18 of 59 IBC patients (31%), distant lesions were found. On the basis of a univariate analysis of the first enrolled patients (n = 42), among 28 patients who showed intense tumoral uptake (standard uptake value(max){>=}5), the 11 patients with distant lesions had a worse prognosis than the 17 patients without distant lesions (P =.04). Conclusions: FDG-PET/CT imaging provides additional invaluable information regarding nodal status or distant metastases in IBC patients and should be considered in the initial staging. It seems also that some prognostic information can be derived from FDG uptake characteristics. (authors)

  12. A new methodological approach for PET implementation in radiotherapy treatment planning.

    Science.gov (United States)

    Bellan, Elena; Ferretti, Alice; Capirci, Carlo; Grassetto, Gaia; Gava, Marcello; Chondrogiannis, Sotirios; Virdis, Graziella; Marzola, Maria Cristina; Massaro, Arianna; Rubello, Domenico; Nibale, Otello

    2012-05-01

    In this paper, a new methodological approach to using PET information in radiotherapy treatment planning has been discussed. Computed tomography (CT) represents the primary modality to plan personalized radiation treatment, because it provides the basic electron density map for correct dose calculation. If PET scanning is also performed it is typically coregistered with the CT study. This operation can be executed automatically by a hybrid PET/CT scanner or, if the PET and CT imaging sets have been acquired through different equipment, by a dedicated module of the radiotherapy treatment planning system. Both approaches have some disadvantages: in the first case, the bore of a PET/CT system generally used in clinical practice often does not allow the use of certain bulky devices for patient immobilization in radiotherapy, whereas in the second case the result could be affected by limitations in window/level visualization of two different image modalities, and the displayed PET volumes can appear not to be related to the actual uptake into the patient. To overcome these problems, at our centre a specific procedure has been studied and tested in 30 patients, allowing good results of precision in the target contouring to be obtained. The process consists of segmentation of the biological target volume by a dedicated PET/CT console and its export to a dedicated radiotherapy system, where an image registration between the CT images acquired by the PET/CT scanner and a large-bore CT is performed. The planning target volume is contoured only on the large-bore CT and is used for virtual simulation, to individuate permanent skin markers on the patient.

  13. Discordant Findings of Skeletal Metastasis Between Tc99m MDP Bone Scans and F18 FDG PET/CT Imaging for Advanced Breast and Lung Cancers—Two Case Reports and Literature Review

    Directory of Open Access Journals (Sweden)

    Yu-Wen Chen

    2007-12-01

    Full Text Available Traditionally, Tc99m methyl diphosphate (MDP bone scintigraphy provides high-sensitivity detection of skeletal metastasis from breast and lung cancers in regular follow-up. Fluorodeoxyglucose (FDG positron emission tomography/computed tomography (PET/CT, based on the glucose metabolism of malignant cells, plays a role in describing rumor growth, proliferation of neoplasm and the extent of metastasis. In general, concordant findings of skeletal metastasis are seen on both types of image, especially in cases of breast and lung cancer. However, there were extremely discordant findings of skeletal metastasis between bone scans and F18 FDG PET/CT imaging in two cases among 300 consecutive F18 FDG PET/CT follow-up exams of patients with malignancies, during the past year, in our center. Both cases, one of breast cancer and one of lung cancer, had negative bone scintigraphic findings, but a diffusely high grade of F18 FDG avid marrow infiltration in the axial spine, leading to the diagnosis of stage IV disease in both cases. Owing to variant genetic aberrance of malignance, F18 FDG PET/CT reveals direct evidence of diffuse, rapid neoplasm metabolism in the bone marrow of the spine, but not of secondary osteoblastic reactions in vivo. F18 FDG PET/CT should always be employed in the follow-up of patients with malignancies.

  14. The impact of the PET/CT in comparison with the same day contrast enhanced CT in breast cancer management

    International Nuclear Information System (INIS)

    Piperkova, E.; Raphael, B.; Altinyay, M.; Castellon, I.; Libes, R.; Abdel-Dayem, H.

    2006-01-01

    Full text: The aim of this study is to evaluate the impact of 18F-fluorodeoxyglucose FDG positron emission tomography with fused computerized tomography (PET/CT) in comparison with the same day contrast enhanced CT (CE-CT) in the breast cancer (BC) management. 68 studies in 48 BC patients, 8 for initial and 60 for restaging disease, after surgery, radiation/chemotherapy, for radiation therapy planning or evaluating treatment response were included. All patients underwent whole body PET/CT for diagnostic purposes followed by CE-CT diagnostic scans of selected body regions. PET/CT was performed approximately 90 minutes following 10-15 mCi of 18F-FDG on a GE Discovery PET/CT system. CT part acquired with low dose X-ray for localization and attenuation correction. The CE-CT was performed according to departmental protocol. Out of a total of 235 lesions in 68 PET/CT and CE-CT studies, 189 were concordant between PET/CT and CE-CT. However, there were 46 discordant lesions, which were verified by either follow-up or biopsy. PET/CT correctly identified 25 (True Positive-TP). CE-CT identified 2 TP lesions missed by PET/CT (False negative): one liver metastasis with necrosis, which is a known non-avid FDG, the other was a missed abdominal metastatic node, which did not change staging or treatment. PET/CT incorrectly identified 2 lesions (False Positive) while CE-CT incorrectly identified 17 FP. For evaluating treatment response in 40 follow up studies PET/CT reported complete response in 15, partial response in 11, stable disease in 2, progression in 5, and free of disease following surgery - in 7. The CE-CT described progression of the disease in 1 PET/CT true negative study and no progression in 2 TP PET/CT studies. In this study, PET/CT played more important role than CECT scans alone and provided an impact on the management of BC patients

  15. The Diagnostic Value of 18F-FDG PET/CT in Association with Serum Tumor Marker Assays in Breast Cancer Recurrence and Metastasis

    Directory of Open Access Journals (Sweden)

    Ying Dong

    2015-01-01

    Full Text Available Background. After initial treatment of breast cancer (BC, monitoring locoregional recurrence and distant metastases is a great clinical challenge. Objective. To evaluate the efficacy of PET/CT in association with serum tumor makers in BC follow-up. Methods. Twenty-six women with a history of modified radical mastectomy were evaluated by 18F-FDG PET/CT. The results of PET/CT were compared with those of conventional imaging techniques (CITs (including mammography, chest radiography, CT, MRI, ultrasound, and bone scintigraphy. Serum tumor markers of CEA, CA 125, and CA 15-3 in the BC patients were also analyzed in association with the results of PET/CT. Results. Compared with CITs, PET/CT was more sensitive to detect the malignant foci and had better patient-based sensitivity and specificity. The mean CA 15-3 serum level was significantly higher in the confirmed positive patients of PET/CT results than in the confirmed negative ones, while there were no significant differences in the serum levels of CEA and CA 125 of both groups. Conclusion. PET/CT is a highly efficient tool for BC follow-up compared with CITs. The high serum levels of CA 15-3 in confirmed positive PET/CT patients indicated the clinical value of CA 15-3 in BC follow-up.

  16. Does the pretreatment tumor sampling location correspond with metabolic activity on 18F-FDG PET/CT in breast cancer patients scheduled for neoadjuvant chemotherapy?

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B., E-mail: b.koolen@nki.nl [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Elshof, Lotte E. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Loo, Claudette E. [Department of Radiology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Wesseling, Jelle [Department of Pathology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Vogel, Wouter V. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Rutgers, Emiel J.Th. [Department of Surgical Oncology, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands); Valdés Olmos, Renato A. [Department of Nuclear Medicine, Netherlands Cancer Institute – Antoni van Leeuwenhoek Hospital, Plesmanlaan 121, 1066 CX Amsterdam (Netherlands)

    2013-12-01

    Purpose: To define the correlation between the core biopsy location and the area with highest metabolic activity on 18F-FDG PET/CT in stage II–III breast cancer patients before neoadjuvant chemotherapy. Also, we would like to select a subgroup of patients in which PET/CT information may optimize tumor sampling. Methods: A PET/CT in prone position was acquired in 199 patients with 203 tumors. The distance and relative difference in standardized uptake value (SUV) between core biopsy localization (indicated by a marker) and area with highest degree of FDG uptake were evaluated. A distance ≥2 cm and a relative difference in SUV ≥25% were considered clinically relevant and a combination of both was defined as non-correspondence. Non-correspondence for different tumor characteristics (TNM stage, lesion morphology on MRI and PET/CT, histology, subtype, grade, and Ki-67) was assessed. Results: Non-correspondence was found in 28 (14%) of 203 tumors. Non-correspondence was significantly associated with T-stage, lesion morphology on MRI and PET/CT, tumor diameter, and histologic type. It was more often seen in tumors with a higher T-stage (p = 0.028), diffuse (non-mass) and multifocal tumors on MRI (p = 0.001), diffuse and multifocal tumors on PET/CT (p < 0.001), tumors >3 cm (p < 0.001), and lobular carcinomas (p < 0.001). No association was found with other features. Conclusion: Non-correspondence between the core biopsy location and area with highest FDG uptake is regularly seen in stage II–III breast cancer patients. PET/CT information and possibly FDG-guided biopsies are most likely to improve pretreatment tumor sampling in tumors >3 cm, lobular carcinomas, and diffuse and multifocal tumors.

  17. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    Science.gov (United States)

    Cucciati, G.; Auffray, E.; Bugalho, R.; Cao, L.; Di Vara, N.; Farina, F.; Felix, N.; Frisch, B.; Ghezzi, A.; Juhan, V.; Jun, D.; Lasaygues, P.; Lecoq, P.; Mensah, S.; Mundler, O.; Neves, J.; Paganoni, M.; Peter, J.; Pizzichemi, M.; Siles, P.; Silva, J. C.; Silva, R.; Tavernier, S.; Tessonnier, L.; Varela, J.

    2014-03-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information.

  18. Development of ClearPEM-Sonic, a multimodal mammography system for PET and Ultrasound

    International Nuclear Information System (INIS)

    Cucciati, G; Vara, N Di; Ghezzi, A; Paganoni, M; Pizzichemi, M; Auffray, E; Frisch, B; Lecoq, P; Bugalho, R; Neves, J; Cao, L; Peter, J; Farina, F; Felix, N; Juhan, V; Mundler, O; Siles, P; Jun, D; Lasaygues, P; Mensah, S

    2014-01-01

    ClearPEM-Sonic is an innovative imaging device specifically developed for breast cancer. The possibility to work in PEM-Ultrasound multimodality allows to obtain metabolic and morphological information increasing the specificity of the exam. The ClearPEM detector is developed to maximize the sensitivity and the spatial resolution as compared to Whole-Body PET scanners. It is coupled with a 3D ultrasound system, the SuperSonic Imagine Aixplorer that improves the specificity of the exam by providing a tissue elasticity map. This work describes the ClearPEM-Sonic project focusing on the technological developments it has required, the technical merits (and limits) and the first multimodal images acquired on a dedicated phantom. It finally presents selected clinical case studies that confirm the value of PEM information

  19. Towards integration of PET/MR hybrid imaging into radiation therapy treatment planning

    International Nuclear Information System (INIS)

    Paulus, Daniel H.; Thorwath, Daniela; Schmidt, Holger; Quick, Harald H.

    2014-01-01

    Purpose: Multimodality imaging has become an important adjunct of state-of-the-art radiation therapy (RT) treatment planning. Recently, simultaneous PET/MR hybrid imaging has become clinically available and may also contribute to target volume delineation and biological individualization in RT planning. For integration of PET/MR hybrid imaging into RT treatment planning, compatible dedicated RT devices are required for accurate patient positioning. In this study, prototype RT positioning devices intended for PET/MR hybrid imaging are introduced and tested toward PET/MR compatibility and image quality. Methods: A prototype flat RT table overlay and two radiofrequency (RF) coil holders that each fix one flexible body matrix RF coil for RT head/neck imaging have been evaluated within this study. MR image quality with the RT head setup was compared to the actual PET/MR setup with a dedicated head RF coil. PET photon attenuation and CT-based attenuation correction (AC) of the hardware components has been quantitatively evaluated by phantom scans. Clinical application of the new RT setup in PET/MR imaging was evaluated in anin vivo study. Results: The RT table overlay and RF coil holders are fully PET/MR compatible. MR phantom and volunteer imaging with the RT head setup revealed high image quality, comparable to images acquired with the dedicated PET/MR head RF coil, albeit with 25% reduced SNR. Repositioning accuracy of the RF coil holders was below 1 mm. PET photon attenuation of the RT table overlay was calculated to be 3.8% and 13.8% for the RF coil holders. With CT-based AC of the devices, the underestimation error was reduced to 0.6% and 0.8%, respectively. Comparable results were found within the patient study. Conclusions: The newly designed RT devices for hybrid PET/MR imaging are PET and MR compatible. The mechanically rigid design and the reproducible positioning allow for straightforward CT-based AC. The systematic evaluation within this study provides the

  20. 18F-FDG PET/CT显像对乳腺癌术后复发及转移的诊断价值%18F-FDG PET/CT in detection of recurrence and metastasis of breast cancer

    Institute of Scientific and Technical Information of China (English)

    林丽莉; 吴湖炳; 王全师

    2011-01-01

    目的 探讨18F-脱氧葡萄糖正电子发射体层摄影术(FDG PET)/CT显像对乳腺癌术后复发、转移的诊断价值.方法 对乳腺癌术后患者104例进行全身18F-FDG PET/CT显像检查.复发或转移灶依据手术或活组织病理学检查、多种影像学检查及临床随访确诊,随访时间大于6个月.结果 104例患者中,肿瘤复发、转移52例.以患者为单位计算,18F-FDG PET/CT诊断乳腺癌术后复发和(或)转移的灵敏度为100%,特异性为98.1%,准确性为99.0%,阳性预测值为98.1%,阴性预测值为100%.以病灶为单位计算,18F-FDG PET/CT诊断乳腺癌术后复发和(或)转移的灵敏度为98.3%,特异性为75.0%,准确性为96.8%,阳性预测值为98.3%,阴性预测值为75.0%.18F-FDG PET/CT显像使8例(15.4%)患者改变了临床再分期,其中7例提高了临床再分期、1例降低了临床再分期.结论 18F-FDG PET/CT对乳腺癌术后复发和(或)转移的诊断具有重要临床价值.%Objective To evaluate the value of positron emission tomography/computed tomography(PET/CT)with 18 F-fluoro deoxy-glucose(18 F-FDG)in detecting recurrence and metastasis of breast cancer. Methods 18 F-FDG PET/CT was studied in 104 patients with breast cancer after surgery. The diagnosis of recurrent tumor and ( or) metastasts was based on pathoiogic examination, multi-modality imagings and clinical follow-up for more than 6 months. The diagnostic competent of PET/CT was assessed by comparing with the clinical findings. Results In total 104 patients, recurrent and(or)metastasis tumors were proved in 52 patients. By the patient-based unit, the sensitivity, specificity,accuracy,positive predictive value and negatice predictive value of PET/CT in detecting recurrent tumor and/or metastasis were 100% , 98. 1% , 99. 0% , 98. 1% and 100 % , respectively. By the lesions-based unit, the sensitivity, specificity, accuracy, positive predictive value and negatice predictive value of PET/CT were 98. 2% , 75

  1. Guide to clinical PET in oncology: Improving clinical management of cancer patients

    International Nuclear Information System (INIS)

    2008-10-01

    Positron emission tomography (PET) has an approximately 50 year-history. It was developed as a tool of medical science to quantitatively measure metabolic rates of bio-substances in vivo and in particular the number of receptors in neuroscience. Until the late 1990s PET was, in most cases, research oriented activity. In 2001, positron emission tomography/X ray computed tomography (PET/CT) hybrid imaging system became commercially available. An era of clinical PET then emerged, in which PET images were utilized for clinical practice in the treatment and diagnosis of cancer patients. PET imaging could recognize areas of abnormal metabolic behaviour of cancers in vivo, and the addition of CT imaging underlines the site of malignancy. More accurate and precise interpretation of cancer lesions can therefore be performed by PET/CT imaging than PET or CT imaging alone. Clinical PET, in particular with fluorine-18-fluorodeoxyglucose ( 18 F-FDG), has already proven itself to have considerable value in oncology. The indications include malignant lymphoma and melanoma, head and neck cancers, oesophageal cancer, breast cancer, lung cancer and colorectal cancer, and it is still being expanded. The roles of clinical PET could be for 1) preoperative staging of cancers, 2) differentiation between residual tumour and scarring, 3) demonstration of suspected recurrences, 4) monitoring response to therapy, 5) prognosis and 6) radiotherapy treatment planning. Clinical PET can be used to illustrate exactly which treatment should be applied for a cancer patient as well as where surgeons should operate and where radiation oncologists should target radiation therapy. An almost exponential rise in the introduction of clinical PET, as well as the installation of PET/CT has been seen throughout the world. Clinical PET is currently viewed as the most powerful diagnostic tool in its field. This IAEA-TECDOC presents an overview of clinical PET for cancer patients and a relevant source of

  2. Intra-image referencing for simplified assessment of HER2-expression in breast cancer metastases using the Affibody molecule ABY-025 with PET and SPECT

    Energy Technology Data Exchange (ETDEWEB)

    Sandberg, Dan; Tolmachev, Vladimir; Olofsson, Helena; Carlsson, Joergen; Lindman, Henrik [Uppsala University, Department of Immunology, Genetics and Pathology, Uppsala (Sweden); Velikyan, Irina; Soerensen, Jens [Uppsala University, Section of Nuclear Medicine and PET, Department of Surgical Sciences, Uppsala (Sweden); Wennborg, Anders; Feldwisch, Joachim [Affibody AB, Solna (Sweden)

    2017-08-15

    In phase I/II-studies radiolabelled ABY-025 Affibody molecules identified human epidermal growth factor receptor 2 (HER2) expression in breast cancer metastases using PET and SPECT imaging. Here, we wanted to investigate the utility of a simple intra-image normalization using tumour-to-reference tissue-ratio (T/R) as a HER2 status discrimination strategy to overcome potential issues related to cross-calibration of scanning devices. Twenty-three women with pre-diagnosed HER2-positive/negative metastasized breast cancer were scanned with [{sup 111}In]-ABY-025 SPECT/CT (n = 7) or [{sup 68}Ga]-ABY-025 PET/CT (n = 16). Uptake was measured in all metastases and in normal spleen, lung, liver, muscle, and blood pool. Normal tissue uptake variation and T/R-ratios were established for various time points and for two different doses of injected peptide from a total of 94 whole-body image acquisitions. Immunohistochemistry (IHC) was used to verify HER2 expression in 28 biopsied metastases. T/R-ratios were compared to IHC findings to establish the best reference tissue for each modality and each imaging time-point. The impact of shed HER2 in serum was investigated. Spleen was the best reference tissue across modalities, followed by blood pool and lung. Spleen-T/R was highly correlated to PET SUV in metastases after 2 h (r = 0.96,P < 0.001) and reached an accuracy of 100% for discriminating IHC HER2-positive and negative metastases at 4 h (PET) and 24 h (SPECT) after injection. In a single case, shed HER2 resulted in intense tracer retention in blood. In the remaining patients shed HER2 was elevated, but without significant impact on ABY-025 biodistribution. T/R-ratios using spleen as reference tissue accurately quantify HER2 expression with radiolabelled ABY-025 imaging in breast cancer metastases with SPECT and PET. Tracer binding to shed HER2 in serum might affect quantification in the extreme case. (orig.)

  3. Utility of 18F-fluoro-deoxyglucose emission tomography/computed tomography fusion imaging (18F-FDG PET/CT in combination with ultrasonography for axillary staging in primary breast cancer

    Directory of Open Access Journals (Sweden)

    Tamura Katsumi

    2008-06-01

    Full Text Available Abstract Background Accurate evaluation of axillary lymph node (ALN involvement is mandatory before treatment of primary breast cancer. The aim of this study is to compare preoperative diagnostic accuracy between positron emission tomography/computed tomography with 18F-fluorodeoxyglucose (18F-FDG PET/CT and axillary ultrasonography (AUS for detecting ALN metastasis in patients having operable breast cancer, and to assess the clinical management of axillary 18F-FDG PET/CT for therapeutic indication of sentinel node biopsy (SNB and preoperative systemic chemotherapy (PSC. Methods One hundred eighty-three patients with primary operable breast cancer were recruited. All patients underwent 18F-FDG PET/CT and AUS followed by SNB and/or ALN dissection (ALND. Using 18F-FDG PET/CT, we studied both a visual assessment of 18F-FDG uptake and standardized uptake value (SUV for axillary staging. Results In a visual assessment of 18F-FDG PET/CT, the diagnostic accuracy of ALN metastasis was 83% with 58% in sensitivity and 95% in specificity, and when cut-off point of SUV was set at 1.8, sensitivity, specificity, and accuracy were 36, 100, and 79%, respectively. On the other hand, the diagnostic accuracy of AUS was 85% with 54% in sensitivity and 99% in specificity. By the combination of 18F-FDG PET/CT and AUS to the axilla, the sensitivity, specificity, and accuracy were 64, 94, and 85%, respectively. If either 18F-FDG PET uptake or AUS was positive in allixa, the probability of axillary metastasis was high; 50% (6 of 12 in 18F-FDG PET uptake only, 80% (4 of 5 in AUS positive only, and 100% (28 of 28 in dual positive. By the combination of AUS and 18F-FDG PET/CT, candidates of SNB were more appropriately selected. The axillary 18F-FDG uptake was correlated with the maximum size and nuclear grade of metastatic foci (p = 0.006 and p = 0.03. Conclusion The diagnostic accuracy of 18F-FDG PET/CT was shown to be nearly equal to ultrasound, and considering their

  4. A meta-analysis of {sup 18}FDG-PET, MRI and bone scintigraphy for diagnosis of bone metastases in patients with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Tao; Yang, Hui-Lin [The First Affiliated Hospital of Soochow University, Department of Orthopaedic Surgery, Suzhou (China); Cheng, Tao [Shanghai Jiaotong University School of Medicine, Department of Orthopaedic Surgery, Shanghai Sixth People' s Hospital, Shanghai (China); Xu, Wen [Public Health School of Soochow University, Department of Epidemiology and Biostatistics, Suzhou (China); Yan, Wei-Li [Shanghai Jiaotong University School of Medicine, Departments of Nuclear Medicine, Shanghai Renji Hospital, Shanghai (China); Liu, Jia [Shanghai Jiaotong University School of Medicine, Departments of Radiology, Shanghai Renji Hospital, Shanghai (China)

    2011-05-15

    To perform a meta-analysis comparing the diagnostic value of {sup 18}FDG-PET, MRI, and bone scintigraphy (BS) in detecting bone metastases in patients with breast cancer. MEDLINE, EMBASE, Scopus, ScienceDirect, SpringerLink, Web of Knowledge, EBSCO, and the Cochrane Database of Systematic Review databases were searched for relevant original articles published from January 1995 to January 2010. Inclusion criteria was as follows: {sup 18}FDG-PET, MRI or {sup 99m}Tc-MDP BS was performed to detect bone metastases (the number of published CT studies was inadequate for meta-analysis and therefore could not be included in this study); sufficient data were presented to construct a 2 x 2 contingency table; histopathological analysis and/or close clinical and imaging follow-up for at least 6 months were used as the reference standard. Two reviewers independently assessed potentially eligible studies and extracted relevant data. A software program called ''META-DiSc'' was used to obtain the pooled estimates for sensitivity, specificity, diagnostic odds ratio (DOR), summary receiver operating characteristic (SROC) curves, and the *Q index for each modality. Thirteen articles consisting of 23 studies fulfilled all inclusion criteria. On a per-patient basis, the pooled sensitivity estimates for MRI (97.1%) were significantly higher than those for PET (83.3%) and BS (87.0%; P <0.05). There was no significant difference between PET and BS (P <0.05). The pooled specificity estimates for PET (94.5%) and MRI (97.0%) were both significantly higher than those for BS (88.1%; P <0.05). There was no significant difference between PET and MRI (P >0.05). The pooled DOR estimates for MRI (298.5) were significantly higher than those for PET (82.1%) and BS (49.3%; P <0.05). There was no significant difference between PET and BS (P >0.05). The SROC curve for MRI showed better diagnostic accuracy than those for PET and BS. The SROC curve for PET was better than that for BS

  5. PET scan for breast cancer

    Science.gov (United States)

    ... radioactive substance (called a tracer) to look for breast cancer. This tracer can help identify areas of cancer ... only after a woman has been diagnosed with breast cancer. It is done to see if the cancer ...

  6. Small animal PET: aspects of performance assessment

    International Nuclear Information System (INIS)

    Weber, Simone; Bauer, Andreas

    2004-01-01

    Dedicated small animal positron emission tomography (PET) systems are increasingly prevalent in industry (e.g. for preclinical drug development) and biological research. Such systems permit researchers to perform animal studies of a longitudinal design characterised by repeated measurements in single animals. With the advent of commercial systems, scanners have become readily available and increasingly popular. As a consequence, technical specifications are becoming more diverse, making scanner systems less broadly applicable. The investigator has, therefore, to make a decision regarding which type of scanner is most suitable for the intended experiments. This decision should be based on gantry characteristics and the physical performance. The first few steps have been taken towards standardisation of the assessment of performance characteristics of dedicated animal PET systems, though such assessment is not yet routinely implemented. In this review, we describe current methods of evaluation of physical performance parameters of small animal PET scanners. Effects of methodologically different approaches on the results are assessed. It is underscored that particular attention has to be paid to spatial resolution, sensitivity, scatter fraction and count rate performance. Differences in performance measurement methods are described with regard to commercially available systems, namely the Concorde MicroPET systems P4 and R4 and the quad-HIDAC. Lastly, consequences of differences in scanner performance parameters are rated with respect to applications of small animal PET. (orig.)

  7. Radiopharmacological evaluation of 6-deoxy-6-[{sup 18}F]fluoro-D-fructose as a radiotracer for PET imaging of GLUT5 in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Wuest, Melinda, E-mail: mwuest@ualberta.c [Department of Oncology, University of Alberta - Cross Cancer Institute, Edmonton, AB-T6G 1Z2 (Canada); Trayner, Brendan J. [Department of Physiology, University of Alberta, Edmonton, AB-T6G 1Z2 (Canada); Grant, Tina N. [Department of Physiology, University of Alberta, Edmonton, AB-T6G 1Z2 (Canada); Department of Chemistry, University of Alberta, Edmonton, AB-T6G 1Z2 (Canada); Jans, Hans-Soenke; Mercer, John R.; Murray, David [Department of Oncology, University of Alberta - Cross Cancer Institute, Edmonton, AB-T6G 1Z2 (Canada); West, Frederick G. [Department of Chemistry, University of Alberta, Edmonton, AB-T6G 1Z2 (Canada); McEwan, Alexander J.B.; Wuest, Frank [Department of Oncology, University of Alberta - Cross Cancer Institute, Edmonton, AB-T6G 1Z2 (Canada); Cheeseman, Chris I. [Department of Physiology, University of Alberta, Edmonton, AB-T6G 1Z2 (Canada)

    2011-05-15

    Introduction: Several clinical studies have shown low or no expression of GLUT1 in breast cancer patients, which may account for the low clinical specificity and sensitivity of 2-deoxy-2-[{sup 18}F]fluoro-D-glucose ([{sup 18}F]FDG) used in positron emission tomography (PET). Therefore, it has been proposed that other tumor characteristics such as the high expression of GLUT2 and GLUT5 in many breast tumors could be used to develop alternative strategies to detect breast cancer. Here we have studied the in vitro and in vivo radiopharmacological profile of 6-deoxy-6-[{sup 18}F]fluoro-D-fructose (6-[{sup 18}F]FDF) as a potential PET radiotracer to image GLUT5 expression in breast cancers. Methods: Uptake of 6-[{sup 18}F]FDF was studied in murine EMT-6 and human MCF-7 breast cancer cells over 60 min and compared to [{sup 18}F]FDG. Biodistribution of 6-[{sup 18}F]FDF was determined in BALB/c mice. Tumor uptake was studied with dynamic small animal PET in EMT-6 tumor-bearing BALB/c mice and human xenograft MCF-7 tumor-bearing NIH-III mice in comparison to [{sup 18}F]FDG. 6-[{sup 18}F]FDF metabolism was investigated in mouse blood and urine. Results: 6-[{sup 18}F]FDF is taken up by EMT-6 and MCF-7 breast tumor cells independent of extracellular glucose levels but dependent on the extracellular concentration of fructose. After 60 min, 30{+-}4% (n=9) and 12{+-}1% (n=7) ID/mg protein 6-[{sup 18}F]FDF was found in EMT-6 and MCF-7 cells, respectively. 6-deoxy-6-fluoro-D-fructose had a 10-fold higher potency than fructose to inhibit 6-[{sup 18}F]FDF uptake into EMT-6 cells. Biodistribution in normal mice revealed radioactivity uptake in bone and brain. Radioactivity was accumulated in EMT-6 tumors reaching 3.65{+-}0.30% ID/g (n=3) at 5 min post injection and decreasing to 1.75{+-}0.03% ID/g (n=3) at 120 min post injection. Dynamic small animal PET showed significantly lower radioactivity uptake after 15 min post injection in MCF-7 tumors [standard uptake value (SUV)=0

  8. Phase I Study of 68Ga-HER2-Nanobody for PET/CT Assessment of HER2 Expression in Breast Carcinoma.

    Science.gov (United States)

    Keyaerts, Marleen; Xavier, Catarina; Heemskerk, Johannes; Devoogdt, Nick; Everaert, Hendrik; Ackaert, Chloé; Vanhoeij, Marian; Duhoux, Francois P; Gevaert, Thierry; Simon, Philippe; Schallier, Denis; Fontaine, Christel; Vaneycken, Ilse; Vanhove, Christian; De Greve, Jacques; Lamote, Jan; Caveliers, Vicky; Lahoutte, Tony

    2016-01-01

    Human epidermal growth factor receptor 2 (HER2) status is one of the major tumor characteristics in breast cancer to guide therapy. Anti-HER2 treatment has clear survival advantages in HER2-positive breast carcinoma patients. Heterogeneity in HER2 expression between primary tumor and metastasis has repeatedly been described, resulting in the need to reassess HER2 status during the disease course. To avoid repeated biopsy with potential bias due to tumor heterogeneity, Nanobodies directed against HER2 have been developed as probes for molecular imaging. Nanobodies, which are derived from unique heavy-chain-only antibodies, are the smallest antigen-binding antibody fragments and have ideal characteristics for PET imaging. The primary aims were assessment of safety, biodistribution, and dosimetry. The secondary aim was to investigate tumor-targeting potential. In total, 20 women with primary or metastatic breast carcinoma (score of 2+ or 3+ on HER2 immunohistochemical assessment) were included. Anti-HER2-Nanobody was labeled with (68)Ga via a NOTA derivative. Administered activities were 53-174 MBq (average, 107 MBq). PET/CT scans for dosimetry assessment were obtained at 10, 60, and 90 min after administration. Physical evaluation and blood analysis were performed for safety evaluation. Biodistribution was analyzed for 11 organs using MIM software; dosimetry was assessed using OLINDA/EXM. Tumor-targeting potential was assessed in primary and metastatic lesions. No adverse reactions occurred. A fast blood clearance was observed, with only 10% of injected activity remaining in the blood at 1 h after injection. Uptake was seen mainly in the kidneys, liver, and intestines. The effective dose was 0.043 mSv/MBq, resulting in an average of 4.6 mSv per patient. The critical organ was the urinary bladder wall, with a dose of 0.406 mGy/MBq. In patients with metastatic disease, tracer accumulation well above the background level was demonstrated in most identified sites of

  9. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code

    International Nuclear Information System (INIS)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade

    2011-01-01

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  10. Molecular Imaging and Precision Medicine in Breast Cancer.

    Science.gov (United States)

    Chudgar, Amy V; Mankoff, David A

    2017-01-01

    Precision medicine, basing treatment approaches on patient traits and specific molecular features of disease processes, has an important role in the management of patients with breast cancer as targeted therapies continue to improve. PET imaging offers noninvasive information that is complementary to traditional tissue biomarkers, including information about tumor burden, tumor metabolism, receptor status, and proliferation. Several PET agents that image breast cancer receptors can visually demonstrate the extent and heterogeneity of receptor-positive disease and help predict which tumors are likely to respond to targeted treatments. This review presents applications of PET imaging in the targeted treatment of breast cancer. Copyright © 2016 Elsevier Inc. All rights reserved.

  11. Predictive value of PET-CT for pathological response in stages II and III breast cancer patients following neoadjuvant chemotherapy with docetaxel.

    Science.gov (United States)

    García García-Esquinas, Marta A; Arrazola García, Juan; García-Sáenz, José A; Furió-Bacete, V; Fuentes Ferrer, Manuel E; Ortega Candil, Aída; Cabrera Martín, María N; Carreras Delgado, José L

    2014-01-01

    To prospectively study the value of PET-CT with fluorine-18 fluorodeoxyglucose (FDG) to predict neoadjuvant chemotherapy (NAC) response of locoregional disease of stages II and III breast cancer patients. A written informed consent and approval were obtained from the Ethics Committee. PET-CT accuracy in the prediction of pathologic complete response (pCR) after NAC was studied in primary tumors and lymph node metastasis in 43 women (mean age: 50 years: range: 27-71 years) with histologically proven breast cancer between December 2009 and January 2011. PET-CT was performed at baseline and after NAC. SUV(max) percentage changes (ΔSUV(max)) were compared with pathology findings at surgery. Receiver-operator characteristic (ROC) analysis was used to discriminate between locoregional pCR and non-pCR. In patients not achieving pCR, it was investigated if ΔSUV(max) could accurately identify the residual cancer burden (RCB) classes: RCB-I (minimal residual disease (MRD)), RCB-II (moderate RD), and RCB-III (extensive RD). pCR was obtained in 11 patients (25.6%). Residual disease was found in 32 patients (74.4%): 16 (37.2%) RCB-I, 15 (35.6%) RCB-II and 2 (4.7%) RCB-III. Sensitivity, specificity, and accuracy to predict pCR were 90.9%, 90.6%, and 90.7%, respectively. Specificity was 94.1% in the identification of a subset of patients who had either pCR or MRD. Accuracy of ΔSUV(max) in the locoregional disease of stages II and III breast cancer patients after NAC is high for the identification of pCR cases. Its specificity is potentially sufficient to identify a subgroup of patients who could be managed with conservative surgery. Copyright © 2013 Elsevier España, S.L. and SEMNIM. All rights reserved.

  12. The Prognostic Value of {sup 18}F-FDG PET/CT for Early Recurrence in Operable Breast Cancer: Comparison with TNM Stage

    Energy Technology Data Exchange (ETDEWEB)

    O, Joo Hyun; Choi, Woo Hee; Han, Eun Ji; Choi, Eunkyoung; Chae, Byung Joo; Park, Yonggyu; Kim, Sung Hoon [The Catholic Univ. of Korea, Seoul (Korea, Republic of)

    2013-12-15

    We evaluated whether the maximum standardized uptake values (SUV{sub max}) of primary tumor from the initial staging by {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography ({sup 18}F-FDG PET/CT) of patients with breast cancer could identify patients at risk for early recurrence within 2 years, particularly in comparison to the American Joint Committee on Cancer (AJCC) stage. We reviewed the staging {sup 18}F-FDG PET/CT images of patients with primary breast cancer and their medical records. The SUV{sub max} of the primary tumor was measured. The presence or absence of FDG uptake in the axillary lymph node (ALN) was also assessed. The patient's pathologic primary tumor stage (pT), pathologic regional lymph node stage (pN), stage grouping, age, estrogen receptor (ER) and progesterone receptor (PR) status, and neoadjuvant chemotherapy history were evaluated with the FDG uptake parameters for recurrence within 2 years following the end of first-line therapy. Recurrence within 2 years was present in 9.1%(n =40) out of the 441 patients assessed. The FDG uptake in ALN, pT, pN, stage grouping and neoadjuvant chemotherapy history were prognostic for early recurrence, while primary tumor SUV{sub max}, age, and ER or PR status were not significant on logistic regression. On multivariate analysis, only the stage grouping (odds ratio 2.79; 95 % CI 1.73, 4.48; p <0.0001) and neoadjuvant chemotherapy history (odds ratio 2.70; 95 % CI 1.22, 5.98; p =0.0141) could identify patients at increased risk for recurrence within 2 years. Primary tumor FDG uptake measured by SUV{sub max}, and visual assessment of FDG uptake in the ALN in the initial staging PET/CT of patients with breast cancer may not have additional prognostic value compared with the AJCC stage grouping for early recurrence.

  13. Quantification of FDG-PET/CT with delayed imaging in patients with newly diagnosed recurrent breast cancer.

    Science.gov (United States)

    Baun, Christina; Falch, Kirsten; Gerke, Oke; Hansen, Jeanette; Nguyen, Tram; Alavi, Abass; Høilund-Carlsen, Poul-Flemming; Hildebrandt, Malene G

    2018-05-09

    Several studies have shown the advantage of delayed-time-point imaging with 18F-FDG-PET/CT to distinguish malignant from benign uptake. This may be relevant in cancer diseases with low metabolism, such as breast cancer. We aimed at examining the change in SUV from 1 h (1h) to 3 h (3h) time-point imaging in local and distant lesions in patients with recurrent breast cancer. Furthermore, we investigated the effect of partial volume correction in the different types of metastases, using semi-automatic quantitative software (ROVER™). One-hundred and two patients with suspected breast cancer recurrence underwent whole-body PET/CT scans 1h and 3h after FDG injection. Semi-quantitative standardised uptake values (SUVmax, SUVmean) and partial volume corrected SUVmean (cSUVmean), were estimated in malignant lesions, and as reference in healthy liver tissue. The change in quantitative measures from 1h to 3h was calculated, and SUVmean was compared to cSUVmean. Metastases were verified by biopsy. Of the 102 included patients, 41 had verified recurrent disease with in median 15 lesions (range 1-70) amounting to a total of 337 malignant lesions included in the analysis. SUVmax of malignant lesions increased from 6.4 ± 3.4 [0.9-19.7] (mean ± SD, min and max) at 1h to 8.1 ± 4.4 [0.7-29.7] at 3h. SUVmax in breast, lung, lymph node and bone lesions increased significantly (p < 0.0001) between 1h and 3h by on average 25, 40, 33, and 27%, respectively. A similar pattern was observed with (uncorrected) SUVmean. Partial volume correction increased SUVmean significantly, by 63 and 71% at 1h and 3h imaging, respectively. The highest impact was in breast lesions at 3h, where cSUVmean increased by 87% compared to SUVmean. SUVs increased from 1h to 3h in malignant lesions, SUVs of distant recurrence were in general about twice as high as those of local recurrence. Partial volume correction caused significant increases in these values. However, it is questionable, if

  14. A Very High Spatial Resolution Detector for Small Animal PET

    International Nuclear Information System (INIS)

    Kanai Shah, M.S.

    2007-01-01

    Positron Emission Tomography (PET) is an in vivo analog of autoradiography and has the potential to become a powerful new tool in imaging biological processes in small laboratory animals. PET imaging of small animals can provide unique information that can help in advancement of human disease models as well as drug development. Clinical PET scanners used for human imaging are bulky, expensive and do not have adequate spatial resolution for small animal studies. Hence, dedicated, low cost instruments are required for conducting small animal studies with higher spatial resolution than what is currently achieved with clinical as well as dedicated small animal PET scanners. The goal of the proposed project is to investigate a new all solid-state detector design for small animal PET imaging. Exceptionally high spatial resolution, good timing resolution, and excellent energy resolution are expected from the proposed detector design. The Phase I project was aimed at demonstrating the feasibility of producing high performance solid-state detectors that provide high sensitivity, spatial resolution, and timing characteristics. Energy resolution characteristics of the new detector were also investigated. The goal of the Phase II project is to advance the promising solid-state detector technology for small animal PET and determine its full potential. Detectors modules will be built and characterized and finally, a bench-top small animal PET system will be assembled and evaluated

  15. Combined approach of perioperative 18F-FDG PET/CT imaging and intraoperative 18F-FDG handheld gamma probe detection for tumor localization and verification of complete tumor resection in breast cancer

    Directory of Open Access Journals (Sweden)

    Knopp Michael V

    2007-12-01

    Full Text Available Abstract Background 18F-fluorodeoxyglucose (18F-FDG positron emission tomography/computed tomography (PET/CT has become an established method for detecting hypermetabolic sites of known and occult disease and is widely used in oncology surgical planning. Intraoperatively, it is often difficult to localize tumors and verify complete resection of tumors that have been previously detected on diagnostic PET/CT at the time of the original evaluation of the cancer patient. Therefore, we propose an innovative approach for intraoperative tumor localization and verification of complete tumor resection utilizing 18F-FDG for perioperative PET/CT imaging and intraoperative gamma probe detection. Methods Two breast cancer patients were evaluated. 18F-FDG was administered and PET/CT was acquired immediately prior to surgery. Intraoperatively, tumors were localized and resected with the assistance of a handheld gamma probe. Resected tumors were scanned with specimen PET/CT prior to pathologic processing. Shortly after the surgical procedure, patients were re-imaged with PET/CT utilizing the same preoperatively administered 18F-FDG dose. Results One patient had primary carcinoma of breast and a metastatic axillary lymph node. The second patient had a solitary metastatic liver lesion. In both cases, preoperative PET/CT verified these findings and demonstrated no additional suspicious hypermetabolic lesions. Furthermore, intraoperative gamma probe detection, specimen PET/CT, and postoperative PET/CT verified complete resection of the hypermetabolic lesions. Conclusion Immediate preoperative and postoperative PET/CT imaging, utilizing the same 18F-FDG injection dose, is feasible and image quality is acceptable. Such perioperative PET/CT imaging, along with intraoperative gamma probe detection and specimen PET/CT, can be used to verify complete tumor resection. This innovative approach demonstrates promise for assisting the oncologic surgeon in localizing and

  16. MicroPET/CT Imaging of AXL Downregulation by HSP90 Inhibition in Triple-Negative Breast Cancer

    Directory of Open Access Journals (Sweden)

    Wanqin Wang

    2017-01-01

    Full Text Available AXL receptor tyrosine kinase is overexpressed in a number of solid tumor types including triple-negative breast cancer (TNBC. AXL is considered an important regulator of epithelial-to-mesenchymal transition (EMT and a potential therapeutic target for TNBC. In this work, we used microPET/CT with 64Cu-labeled anti-human AXL antibody (64Cu-anti-hAXL to noninvasively interrogate the degradation of AXL in vivo in response to 17-allylamino-17-demethoxygeldanamycin (17-AAG, a potent inhibitor of HSP90. 17-AAG treatment caused significant decline in AXL expression in orthotopic TNBC MDA-MB-231 tumors, inhibited EMT, and delayed tumor growth in vivo, resulting in significant reduction in tumor uptake of 64Cu-anti-hAXL as clearly visualized by microPET/CT. Our data indicate that 64Cu-anti-hAXL can be useful for monitoring anti-AXL therapies and for assessing inhibition of HSP90 molecular chaperone using AXL as a molecular surrogate.

  17. Prospective Clinical Trial of 18F-Fluciclovine PET/CT for Determining the Response to Neoadjuvant Therapy in Invasive Ductal and Invasive Lobular Breast Cancers.

    Science.gov (United States)

    Ulaner, Gary A; Goldman, Debra A; Corben, Adriana; Lyashchenko, Serge K; Gönen, Mithat; Lewis, Jason S; Dickler, Maura

    2017-07-01

    18 F-labeled 1-amino-3-fluorocyclobutane-1-carboxylic acid ( 18 F-fluciclovine) is a leucine analog radiotracer that depicts amino acid transport into cells. 18 F-fluciclovine PET/CT visualizes malignancy, including prostate cancer, invasive ductal breast cancer, and invasive lobular breast cancer. Whether changes in 18 F-fluciclovine avidity reflect changes in tumor burden resulting from treatment has not been shown. In this prospective clinical trial (clinical trials.gov: NCT01864083), changes in 18 F-fluciclovine avidity after neoadjuvant therapy were compared to breast cancer therapy response, as determined by residual tumor burden on pathology, were evaluated. Methods: Twenty-four women with a new diagnosis of locally advanced invasive ductal breast cancer ( n = 18) or invasive lobular breast cancer ( n = 6) underwent 18 F-fluciclovine PET/CT before and after the completion of neoadjuvant systemic therapy. SUV max , SUV mean , metabolic tumor volume, and total lesion avidity were obtained for the primary breast tumor, axillary lymph nodes, and extraaxillary lymph nodes on each examination and corrected for background 18 F-fluciclovine avidity. The relationship between changes in 18 F-fluciclovine avidity and the percentage of reduction of tumor on pathology was assessed with the Spearman rank correlation. Results: The median decrease in the corrected SUV max of the primary breast lesions was 99% (range, 33%-100%). The median reduction of tumor on pathology was 92% (range, 10%-100%). Changes in 18 F-fluciclovine avidity were strongly correlated with the percentage of reduction of tumor on pathology (Spearman ρ, 0.79; 95% CI, 0.56-0.90; P < 0.001). Conclusion: Changes in 18 F-fluciclovine avidity strongly correlated with the tumor response on pathology in this pilot study. © 2017 by the Society of Nuclear Medicine and Molecular Imaging.

  18. Contribution of 18-FDG-PET/TC in the handling of the locally advanced stadiums of breast cancer

    International Nuclear Information System (INIS)

    Azar, M.; Cresta Morgado, C.; Noblia, C.; Gonzalez, E.; Armanasco, E.; Montoya, D.; Ipina, M.; Gorostidy, A.; Alvarez, A.; Mickiewicz, E.; Bruno, G.; Gonzalez, C.; Parma, P.; Blumenkrantz, Y.

    2010-01-01

    Conventional imaging modalities provide only morphological details and do not provide information on the metabolic status of a lesion, which is very important in differentiating a benign from a malignant lesion. Early diagnosis and reliable imaging assessment of response to treatment are essential in the clinical management of breast cancer. Positron Emission Tomography (PET) has been widely shown to be highly useful for the diagnosis of palpable masses, for staging, for obtaining long-term prognostic information, and for demonstrating tumour response to chemotherapy at an early phase or after completion of treatment in patient with breast cancer. Twenty-three consecutive female patients with primary breast carcinoma (T3/T4,N2,M0) were prospectively recruited for AT--TDG and tumour 18F-IDG update (standardized update value, SUV was used as a metabolic indicator. There was a positive relationship between tumour metabolic and response to chemotherapy and pathological conditions SUV provides an index of regional tracer uptake and a reduced SUV are indicative of tumour regression. (authors) [es

  19. The relationship between vascular and metabolic characteristics of primary breast tumours

    International Nuclear Information System (INIS)

    Semple, Scott I.K.; Gilbert, Fiona J.; Redpath, Thomas W.; Staff, Roger T.; Ahearn, Trevor S.; Welch, Andrew E.; Heys, Steven D.; Hutcheon, Andrew W.; Smyth, Elizabeth H.; Chaturvedi, Shailesh

    2004-01-01

    The objective of this study was to investigate the relationship between vascular and metabolic characteristics of breast tumours in vivo, using contrast-enhanced dynamic MRI and 2-[ 18 F] fluoro-2-deoxy-d-glucose (FDG) PET imaging. Twenty patients with large or locally advanced primary breast cancers were imaged prior to therapy. MRI data were acquired using a dynamic gradient echo sequence and analysed using two pharmacokinetic models. Static PET data were acquired in 2D mode. A significant association (P<0.05) was observed between the calculated exchange rate constants of both pharmacokinetic models and calculated PET FDG dose uptake ratios (DUR). Statistical analysis showed that the exchange rate constants can explain between 27 and 44% of the variance observed in the PET FDG uptake ratios. A relationship was demonstrated between the vascular and metabolic characteristics of primary breast tumours showing that any assessment of tumour metabolic activity using PET may be controlled at least in part by delivery of uptake agent due to the vascular characteristics of the tumour. MRI and PET provide methods of assessing breast tumour vascularity and metabolism in vivo using the exchange rate constants of dynamic MRI, and DUR of PET, respectively, these measures being related but not equivalent. (orig.)

  20. Potential clinical applications of {sup 18}F-fluorodeoxyglucose position emission tomography/magnetic resonance mammography in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Ihn Ho; Kong, Eun Jung [Dept. of Nuclear Medicine, Yeugnam University Hospital, Daegu (Korea, Republic of)

    2017-09-15

    The whole-body positron emission tomography (PET)/magnetic resonance (MR) scan is a cutting edge technology providing comprehensive structural information from MR imaging and functional features from PET in a single session. Recent research findings and clinical experience have shown that 18F-fluorodeoxyglucose (FDG) whole-body PET/MR imaging has a diagnostic performance comparable with or superior to that of PET/CT in the field of oncology, including for breast cancer. In particular, FDG PET/MR mammography in the prone position with the breast hanging in a pendant manner can provide more comprehensive information about the metabolism, anatomy, and functional features of a breast lesion than a whole-body PET/MR scan. This article reports on current state-of-the-art PET/MR mammography in patients with breast cancer and the prospects for potential application in the future.

  1. PET-CT imaging fusion in the assessment of head and neck carcinoma

    International Nuclear Information System (INIS)

    Santos, Denise Takehana dos; Chojniak, Rubens; Lima, Eduardo Nobrega Pereira; Cavalcanti, Marcelo Gusmao Paraiso

    2006-01-01

    Objective: The authors have established a methodological approach to evaluate head and neck squamous cell carcinoma aiming at identifying and distinguishing high metabolic activity inside the lesion, combining in a single examination, functional, metabolic and morphological data simultaneously acquired by means of different non-dedicated positron emission tomography (PET)-computed tomography (CT) device. Materials and Methods: The study population included 17 patients with head and neck squamous cell carcinoma submitted to a non-dedicated 18 F-FDG-PET imaging at Department of Diagnostic Imaging of Hospital do Cancer, Sao Paulo, SP, Brazil. CT and 18 F-FDG-PET images were simultaneously acquired in a non-dedicated device. The original data were transferred to an independent workstation by means of the Entegra 2 NT software to generate PET-CT imaging fusion. Results: The findings were defined as positive in the presence of a well defined focal area of increased radiopharmaceutical uptake in regions not related with the normal biodistribution of the tracer. Conclusion: The fusion of simultaneously acquired images in a single examination ( 18 F-FDGPET and CT) has allowed the topographic-metabolic mapping of the lesion as well as the localization of high metabolic activity areas inside the tumor, indicating recidivation or metastasis and widening the array of alternatives for radiotherapy or surgical planning. (author)

  2. Improved characterization of molecular phenotypes in breast lesions using 18F-FDG PET image homogeneity

    Science.gov (United States)

    Cao, Kunlin; Bhagalia, Roshni; Sood, Anup; Brogi, Edi; Mellinghoff, Ingo K.; Larson, Steven M.

    2015-03-01

    Positron emission tomography (PET) using uorodeoxyglucose (18F-FDG) is commonly used in the assessment of breast lesions by computing voxel-wise standardized uptake value (SUV) maps. Simple metrics derived from ensemble properties of SUVs within each identified breast lesion are routinely used for disease diagnosis. The maximum SUV within the lesion (SUVmax) is the most popular of these metrics. However these simple metrics are known to be error-prone and are susceptible to image noise. Finding reliable SUV map-based features that correlate to established molecular phenotypes of breast cancer (viz. estrogen receptor (ER), progesterone receptor (PR) and human epidermal growth factor receptor 2 (HER2) expression) will enable non-invasive disease management. This study investigated 36 SUV features based on first and second order statistics, local histograms and texture of segmented lesions to predict ER and PR expression in 51 breast cancer patients. True ER and PR expression was obtained via immunohistochemistry (IHC) of tissue samples from each lesion. A supervised learning, adaptive boosting-support vector machine (AdaBoost-SVM), framework was used to select a subset of features to classify breast lesions into distinct phenotypes. Performance of the trained multi-feature classifier was compared against the baseline single-feature SUVmax classifier using receiver operating characteristic (ROC) curves. Results show that texture features encoding local lesion homogeneity extracted from gray-level co-occurrence matrices are the strongest discriminator of lesion ER expression. In particular, classifiers including these features increased prediction accuracy from 0.75 (baseline) to 0.82 and the area under the ROC curve from 0.64 (baseline) to 0.75.

  3. Evaluation of pulmonary nodules and lung cancer with one-inch crystal gamma coincidence positron emission tomography/CT versus dedicated positron emission tomography/CT

    International Nuclear Information System (INIS)

    Moodie, K.; Lau, E.; Hicks, R. J.; Cherk, M. H.; Turlakow, A.; Skinner, S.; Kelly, M. J.; Kalff, V.

    2009-01-01

    Full text: Dedicated positron emission tomography (PET)/CT scanners using BGO and related detectors (d-PET) have become standard imaging instruments in many malignancies. Hybrid gamma camera systems using Nal detectors in coincidence mode (g-PET) have been compared to d-PET but reported usefulness has been variable when gamma cameras with half-inch to three-fourth-inch thick crystals have been used without CT. Our aim was to compare g-PET with a 1-in.-thick crystal and inbuilt CT for lesion localization and attenuation correction (g-PET/CT) and d-PET/CT in patients presenting with potential and confirmed lung malignancies. One hour after 18F-fluorodeoxyglucose (FDG), patients underwent BGO d-PET/CT from jaw to proximal thigh. This was followed by one to two bed position g-PET/CT 194 + 27 min after FDG. Each study pair was independently analysed with concurrent CT. d-PET/CT was interpreted by a radiologist experienced in both PET and CT, and g-PET/CT by consensus reading of an experienced PET physician and an experienced CT radiologist, A TNM score was assigned and studies were then unblinded and compared. Fifty-seven patients underwent 58 scan pairs over 2 years. Eighty-nine percent concordance was shown between g-PET/CT and d-PET/CT for the assessment of I intrapulmonary lesions, with 100% concordance for intrapulmonary lesions I >10 mm (36 of 36). Eighty-eight per cent (51 of 58) concordance was shown between g-PET/CTand d-PET/CTforTNM staging. Coincidence imaging usingan optimized dual-head 1-in.-thick crystal gamma camera with inbuilt CT compares reasonably well with dedicated PET/CT for evaluation of indeterminate pulmonary lesions and staging of pulmonary malignancies and may be of some] value when d-PET/CT is not readily available.

  4. The value of imaging examinations in diagnosis and curative effect evaluation of breast cancer

    International Nuclear Information System (INIS)

    Xia Xiaotian; Zhang Yongxue

    2010-01-01

    Breast cancer is a serious impact on women's physical and mental health and a life-threatening common disease. Imaging examinations have great significances in diagnosing and evaluating curative effect on breast cancer. This article aims to introduce and comprehensive the value of diagnosis and curative effect evaluation of breast cancer in the context of imaging examinations (ultrasonography, mammography, breast CT, breast MRI, breast 99 Tc m -MIBI imaging, PET, PET-CT, etc). (authors)

  5. Demonstration of an Axial PET concept for brain and small animal imaging

    CERN Document Server

    Beltrame, P; Clinthorne, N; Meddi, F; Kagan, H; Braem, A; Pauss, F; Djambazov, L; Lustermann, W; Weilhammer, P; Nessi-Tedaldi, F; Dissertori, G; Renker, D; Schneider, T; Schinzel, D; De Leo, R; Bolle, E; Fanti, V; Rafecas, M; Rudge, A; Stapnes, S; Casella, C; Chesi, E; Seguinot, J; Solevi, P; Joram, C; Oliver, J F

    2011-01-01

    Standard Positron Emission Tomography (PET) cameras need to reach a compromise between spatial resolution and sensitivity. To overcome this limitation we developed a novel concept of PET. Our AX-PET demonstrator is made of LYSO crystals aligned along the z coordinate (patient's axis) and WLS strips orthogonally placed with respect to the crystals. This concept offers full 3D localization of the photon interaction inside the camera. Thus the spatial resolution and the sensitivity can be simultaneously improved and the reconstruction of Compton interactions inside the detector is also possible. Moreover, by means of G-APDs for reading out the photons, both from LYSO and WLS, the detector is insensitive to magnetic fields and it is then suitable to be used in a combined PET/MRI apparatus. A complete Monte Carlo simulation and dedicated reconstruction software have been developed. The two final modules, each composed of 48 crystals and 156 WLS strips, have been built and fully characterized in a dedicated test se...

  6. Impact of (18)F-Fluoride PET on Intended Management of Patients with Cancers Other Than Prostate Cancer: Results from the National Oncologic PET Registry.

    Science.gov (United States)

    Hillner, Bruce E; Siegel, Barry A; Hanna, Lucy; Duan, Fenghai; Shields, Anthony F; Quinn, Bruce; Coleman, R Edward

    2014-07-01

    The National Oncologic PET Registry prospectively assessed the impact of PET with (18)F-sodium fluoride (NaF PET) on intended management of Medicare patients with suspected or known osseous metastasis. We report our findings for cancers other than prostate and make selected comparisons to our previously reported prostate cancer cohort. Data were collected from both referring and interpreting physicians before and after NaF PET in patients (age ≥ 65 y) stratified for initial staging (IS; n = 570), for suspected first osseous metastasis (FOM; n = 1,814; breast, 781 [43%]; lung, 380 [21%]; and all other cancers, 653 [36%]), and for suspected progression of osseous metastasis (POM; n = 435). The dominant indication was bone pain. If NaF PET were unavailable, conventional bone scintigraphy would have been ordered in 85% of patients. In IS, 28% of patients had suspected or confirmed nonosseous metastasis. If neither conventional bone scintigraphy nor NaF PET were available, referring physicians would have ordered other advanced imaging more than 70% of the time rather than initiate treatment for suspected FOM (11%-16%) or POM (18%-22%). When intended management was classified as either treatment or nontreatment, the intended management change for each cancer type was highest in POM, lower in IS, and lowest in FOM. For suspected FOM, intended management change was lower in breast (24%), lung (36%), or other cancers (31%), compared with prostate cancer (44%) (P definite metastases) frequencies were similar across cancer types. After normal/benign/equivocal PET results, 15% of breast, 30% lung, and 38% prostate cancer patients had treatment, likely reflecting differences in management of nonosseous disease. For patients with definite metastasis on NaF PET, nonprostate, compared with prostate, cancer patients had post-PET plans for more frequent biopsy, alternative imaging, chemotherapy, and radiotherapy. In the smaller IS and POM cohorts, differences among cancer types

  7. Cancer screening with FDG-PET

    International Nuclear Information System (INIS)

    Ide, M.

    2006-01-01

    Aim: This study is based on medical health check-up and cancer screening on of a medical health club using PET, MRI, spiral CT and other conventional examinations. Methods: Between October 1994 and June 2005, 9357 asymptomatic members of the health club participated in 24772 screening session (5693 men and 3664 women, mean age 52.2±10.4 years). Results: Malignant tumors were discovered in 296 of the 9357 participants (3.16%) and 24772 screening sessions (1.19%). The detection rate of our program is much higher than that of mass screening in Japan. The thyroid, lung, colon and breast cancers were PET positive, but the prostate, renal and bladder cancers were generally PET negative. Conclusion: FDG-PET has the potential to detect a wide variety of cancers at curable stages in asymptomatic individuals. To reduce false-positive and false-negative results of PET examination, there is a need of experienced radiologist and/or oncologists who had training in the wide aspect of FDG-PET. FDG-PET has limitations in the detection of urological cancers, cancers of low cell density, small cancers and hypo metabolic or FDG non-avid cancers. Therefore, conventional examinations and/or PET/CT are also needed for cancer screening in association with FDG-PET

  8. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    International Nuclear Information System (INIS)

    Zhang, Jian; Hu, Xi-Chun; Jia, Zhen; Ragaz, Joseph; Zhang, Ying-Jian; Zhou, Min; Zhang, Yong-Ping; Li, Gang; Wang, Bi-Yun; Wang, Zhong-Hua

    2013-01-01

    Whether PET scan maximum standard uptake value (SUVmax) could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC) patients with luminal subtype is still unknown and need to be investigated. 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS) or overall survival (OS) after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype

  9. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    Energy Technology Data Exchange (ETDEWEB)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M [Grupo de Fisica Nuclear, Departmento de Fisica Atomica, Molecular y Nuclear, Universidad Complutense de Madrid, Madrid (Spain); Vaquero, J J; Desco, M [Unidad de Medicina y CirugIa Experimental, Hospital General Universitario Gregorio Maranon, Madrid (Spain)], E-mail: jose@nuc2.fis.ucm.es

    2009-03-21

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  10. PeneloPET, a Monte Carlo PET simulation tool based on PENELOPE: features and validation

    International Nuclear Information System (INIS)

    Espana, S; Herraiz, J L; Vicente, E; Udias, J M; Vaquero, J J; Desco, M

    2009-01-01

    Monte Carlo simulations play an important role in positron emission tomography (PET) imaging, as an essential tool for the research and development of new scanners and for advanced image reconstruction. PeneloPET, a PET-dedicated Monte Carlo tool, is presented and validated in this work. PeneloPET is based on PENELOPE, a Monte Carlo code for the simulation of the transport in matter of electrons, positrons and photons, with energies from a few hundred eV to 1 GeV. PENELOPE is robust, fast and very accurate, but it may be unfriendly to people not acquainted with the FORTRAN programming language. PeneloPET is an easy-to-use application which allows comprehensive simulations of PET systems within PENELOPE. Complex and realistic simulations can be set by modifying a few simple input text files. Different levels of output data are available for analysis, from sinogram and lines-of-response (LORs) histogramming to fully detailed list mode. These data can be further exploited with the preferred programming language, including ROOT. PeneloPET simulates PET systems based on crystal array blocks coupled to photodetectors and allows the user to define radioactive sources, detectors, shielding and other parts of the scanner. The acquisition chain is simulated in high level detail; for instance, the electronic processing can include pile-up rejection mechanisms and time stamping of events, if desired. This paper describes PeneloPET and shows the results of extensive validations and comparisons of simulations against real measurements from commercial acquisition systems. PeneloPET is being extensively employed to improve the image quality of commercial PET systems and for the development of new ones.

  11. F-FDG PET/CT (PET/CT) influences management in patients with known or suspected pancreatic cancer

    International Nuclear Information System (INIS)

    Barber, Thomas W.; Kalff, Victor; Cherk, Martin H.; Yap, Kenneth SK.; Evans, Peter; Kelly, Michael J.

    2009-01-01

    Full text: Objective: To assess the impact on clinical management of PET/CT in patients with known or suspected pancreatic cancer. Methods: Between April 2006 and September 2008,25 PET/CT scans were performed using a dedicated PET/CT (22 scans) or a coincidence hybrid PET/CT camera (3 scans) in 23 patients with known or suspected pancreatic cancer. 17 scans were performed for initial evaluation and 8 for restaging of disease. The pre-PET/CT management plan and for intent were prospectively recorded in all cases. The post-PET/CT management plan was determined from the medical record and for discussions with treating clinicians. The impact of PET/CT on management was classified as High, Medium, Low or None, defined using ANZAPNM PET data collection project criteria. Follow-up was used to reconcile any discordance between PET/CT and conventional imaging. Results: Overall, PET/CT management impact was classified as high (n equal 7), medium (n equal 4), low (n equal 10) or none (n equal 4). Impact was either high or medium in l l/25 patients (44%) (95% confidence interval; 24 - 64%). Impact was high in 4/17 patients imaged for initial evaluation, predominantly by clarifying equivocal lesions on conventional imaging. In restaged patients, PET/CT impact was high in 3/8, and it correctly modified disease extent in 5/8. In the 16 discordant studies, PET/CT assessment was correct in 10, conventional imaging in 4 and there was insufficient information in 2. Conclusion: PET/CT has high or medium management impact in 44% of patients imaged for known or suspected pancreatic cancer, more commonly during restaging. Discordant PET/CT results were usually correct.

  12. 18F-FDG-PET/CT in patients with breast cancer and rising Ca 15-3 with negative conventional imaging: A multicentre study

    International Nuclear Information System (INIS)

    Grassetto, Gaia; Fornasiero, Adriano; Otello, Daniele; Bonciarelli, Giorgio; Rossi, Elena; Nashimben, Ottorino; Minicozzi, Anna Maria; Crepaldi, Giorgio; Pasini, Felice; Facci, Enzo; Mandoliti, Giovanni; Marzola, Maria Cristina; Al-Nahhas, Adil; Rubello, Domenico

    2011-01-01

    Objectives: Breast cancer is the second cause of death in women in Europe and North America. The mortality of this disease can be reduced with effective therapy and regular follow up to detect early recurrence. Tumor markers are sensitive in detecting recurrent or residual disease but imaging is required to customize the therapeutic option. Rising tumor markers and negative conventional imaging (US, X-mammography, CT and MR) poses a management problem. Our aim is to assess the role of 18 F-FDG-PET/CT in the management of post-therapy patients with rising markers but negative conventional imaging. Materials and methods: In the period from January 2008 to September 2009, 89 female patients with breast cancer who developed post-therapy rising markers (serum Ca 15-3 levels = 64.8 ± 16.3 U/mL) but negative clinical examination and conventional imaging were investigated with 18 F-FDG-PET/CT. Results: Tumor deposits were detected in 40/89 patients in chest wall, internal mammary nodes, lungs, liver and skeleton. The mean SUVmax value calculated in these lesions was 6.6 ± 1.7 (range 3.1–12.8). In 23/40 patients solitary small lesion were amenable to radical therapy. In 7 out of these 23 patients a complete disease remission lasting more than 1 year was observed. Conclusions: 18 F-FDG-PET/CT may have a potential role in asymptomatic patients with rising markers and negative conventional imaging. Our findings agree with other studies in promoting regular investigations such as tumor markers and 18 F-FDG-PET/CT rather than awaiting the developments of physical symptoms as suggested by current guidelines since the timely detection of early recurrence may have a major impact on therapy and survival.

  13. WE-DE-207B-10: Library-Based X-Ray Scatter Correction for Dedicated Cone-Beam Breast CT: Clinical Validation

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L; Zhu, L [Georgia Institute of Technology, Atlanta, GA (Georgia); Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: Scatter contamination is detrimental to image quality in dedicated cone-beam breast CT (CBBCT), resulting in cupping artifacts and loss of contrast in reconstructed images. Such effects impede visualization of breast lesions and the quantitative accuracy. Previously, we proposed a library-based software approach to suppress scatter on CBBCT images. In this work, we quantify the efficacy and stability of this approach using datasets from 15 human subjects. Methods: A pre-computed scatter library is generated using Monte Carlo simulations for semi-ellipsoid breast models and homogeneous fibroglandular/adipose tissue mixture encompassing the range reported in literature. Projection datasets from 15 human subjects that cover 95 percentile of breast dimensions and fibroglandular volume fraction were included in the analysis. Our investigations indicate that it is sufficient to consider the breast dimensions alone and variation in fibroglandular fraction does not significantly affect the scatter-to-primary ratio. The breast diameter is measured from a first-pass reconstruction; the appropriate scatter distribution is selected from the library; and, deformed by considering the discrepancy in total projection intensity between the clinical dataset and the simulated semi-ellipsoidal breast. The deformed scatter-distribution is subtracted from the measured projections for scatter correction. Spatial non-uniformity (SNU) and contrast-to-noise ratio (CNR) were used as quantitative metrics to evaluate the results. Results: On the 15 patient cases, our method reduced the overall image spatial non-uniformity (SNU) from 7.14%±2.94% (mean ± standard deviation) to 2.47%±0.68% in coronal view and from 10.14%±4.1% to 3.02% ±1.26% in sagittal view. The average contrast to noise ratio (CNR) improved by a factor of 1.49±0.40 in coronal view and by 2.12±1.54 in sagittal view. Conclusion: We demonstrate the robustness and effectiveness of a library-based scatter correction

  14. Determining efficacy of breast cancer therapy by PET imaging of HER2 mRNA

    International Nuclear Information System (INIS)

    Paudyal, Bishnuhari; Zhang, Kaijun; Chen, Chang-Po; Wampole, Matthew E.; Mehta, Neil; Mitchell, Edith P.; Gray, Brian D.; Mattis, Jeffrey A.; Pak, Koon Y.; Thakur, Mathew L.; Wickstrom, Eric

    2013-01-01

    Introduction: Monitoring the effectiveness of therapy early and accurately continues to be challenging. We hypothesize that determination of Human Epidermal Growth Factor Receptor 2 (HER2) mRNA in malignant breast cancer (BC) cells by positron emission tomography (PET) imaging, before and after treatment, would reflect therapeutic efficacy. Method: WT4340, a peptide nucleic acid (PNA) 12-mer complementary to HER2 mRNA was synthesized together with -CSKC, a cyclic peptide, which facilitated internalization of the PNA via IGFR expressed on BC cells, and DOTA that chelated Cu-64. Mice (n = 8) with BT474 ER +/HER2+ human BC received doxorubicin (DOX, 1.5 mg/kg) i.p. once a week for six weeks. Mice (n = 8) without DOX served as controls. All mice were PET imaged with F-18-FDG and 48 h later with Cu-64-WT4340. PET imaging were performed before and 72 h after each treatment. Standardized uptake values (SUVs) were determined and percent change calculated. Animal body weight (BW) and tumor volume (TV) were measured. Results: SUVs for Cu-64-WT4340 after DOX treatment declined by 54% ± 17% after the second dose, 41% ± 15% after the fourth dose, and 29% ± 7% after the sixth dose, compared with 42% ± 22%, 31% ± 18%, and 13% ± 9% (p < 0.05) for F-18-FDG. In untreated mice, the corresponding percent SUVs for Cu-64-WT4340 were 145% ± 82%, 165% ± 39%, and 212% ± 105% of pretreatment SUV, compared with 108% ± 28%, 151% ± 8%, and 152% ± 35.5%, (p < 0.08) for F-18-FDG. TV in mice after second dose was 114.15% ± 61.83%, compared with 144.7% ± 64.4% for control mice. BW of DOX-treated mice was 103.4% ± 7.6% of pretreatment, vs. 100.1% ± 4.3% for control mice. Conclusion: Therapeutic efficacy was apparent sooner by molecular PET imaging than by determination of reduction in TV

  15. Oncological applications of 18F-FDG PET imaging

    International Nuclear Information System (INIS)

    Li Lin

    2000-01-01

    Considering normal distribution of 18 F-FDG in human body, 18 F-FDG imaging using PET can be applied to brain tumors, colorectal cancer, lymphoma, melanoma, lung cancer and head and neck cancer. The author briefly focuses on application of 18 F-FDG PET imaging to breast cancer, pancreatic cancer, hepatocellular carcinoma, musculoskeletal neoplasms, endocrine neoplasms, genitourinary neoplasms, esophageal and gastric carcinomas

  16. The relationship between estrogen receptor, progesterone receptor and human epidermal growth factor receptor 2 expression of breast cancer and the retention index in dual phase {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Noh, Woo Chul; Kim, Hyun Ah; Kim, Eun Kyu [Dept.of Surgery, Korea Cancer Center HospitalKorea Institute of Radiological and Medical Sciences (KIRAMS), Seoul (Korea, Republic of); and others

    2016-09-15

    This study investigates the correlation of retention index (RI) using the dual phase FDG PET/CT scan with the breast cancer biomarkers. A total of 55 patients with breast cancer underwent dual phase FDG PET/CT scans (60 and 120 min after FDG injection) before treatment. SUVmax and SUVmean of the primary breast tumors were measured, then the percent change of SUVmax and SUVmean between the two scans were calculated, and denoted as RImax and RImean, respectively. After the surgical resection of the breast tumor, the status of biomarkers (ER, PR, and HER-2) was evaluated in the postsurgical specimen. RImean was significantly higher in ER (−) (median, 16.2; IQR, 10.8–21.0) or HER-2 (+) (median, 16.1; IQR, 10.7–21.6) tumors than in ER (+) tumors (median, 9.9; IQR, 5.5–15.3) or HER-2 (−) tumors (median, 10.5; IQR, 5.5–16.1). However, there were no significant differences of SUVmax or RImax according to the ER or HER-2 status. There were no significant differences of any PET parameters between PR (+) and PR (−) tumors. Based off ROC curve analyses, RImean predicted the ER (+) tumors (AUC, 0.699; p = 0.006), and HER-2 (+) tumors (AUC, 0.674; p = 0.022), but not the PR (+) tumors. However, neither SUVmax nor RImax predicted ER (+), PR (+), or HER-2 (+) tumors. Retention index of SUVmean can reflect the ER and HER-2 status of breast cancers. Higher retention index of SUVmean might associate with lower ER expression and higher HER-2 expression.

  17. FDG PET/CT findings in a clinically diagnosed case of childhood autism

    International Nuclear Information System (INIS)

    Manglunia, Ashmi S.; Puranik, Ameya D.

    2016-01-01

    Autism is a neurodevelopmental disorder with multifactorial etiology and varied presentation, in which early diagnosis is crucial to the implementation of early treatment. A 6-year-old child clinically diagnosed with autism, and a normal magnetic resonance imaging underwent dedicated 18F-fluorodeoxyglucose brain positron emission tomography (PET) as an ancillary investigation. PET image showed diffuse bilateral temporal hypometabolism. Although PET imaging is currently not indicated in the evaluation of autism, characteristic imaging patterns on PET can provide corroborative information and increase the diagnostic confidence for the same

  18. Monte Carlo simulations in small animal PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Branco, Susana [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)], E-mail: susana.silva@fc.ul.pt; Jan, Sebastien [Service Hospitalier Frederic Joliot, CEA/DSV/DRM, Orsay (France); Almeida, Pedro [Universidade de Lisboa, Faculdade de Ciencias, Instituto de Biofisica e Engenharia Biomedica, Lisbon (Portugal)

    2007-10-01

    This work is based on the use of an implemented Positron Emission Tomography (PET) simulation system dedicated for small animal PET imaging. Geant4 Application for Tomographic Emission (GATE), a Monte Carlo simulation platform based on the Geant4 libraries, is well suited for modeling the microPET FOCUS system and to implement realistic phantoms, such as the MOBY phantom, and data maps from real examinations. The use of a microPET FOCUS simulation model with GATE has been validated for spatial resolution, counting rates performances, imaging contrast recovery and quantitative analysis. Results from realistic studies of the mouse body using {sup -}F and [{sup 18}F]FDG imaging protocols are presented. These simulations include the injection of realistic doses into the animal and realistic time framing. The results have shown that it is possible to simulate small animal PET acquisitions under realistic conditions, and are expected to be useful to improve the quantitative analysis in PET mouse body studies.

  19. Usefulness of 18F-FDG uptake with clinicopathologic and immunohistochemical prognostic factors in breast cancer

    International Nuclear Information System (INIS)

    Kim, Bom Sahn; Sung, Sun Hee

    2012-01-01

    The aim of this study was to analyze the clinical significance of max standardized uptake value (maxSUV) with clinicopathologic and immunohistochemical prognostic factors in patients with primary breast cancer. Ninety-one women (48.5±11.2 years of age) with breast cancer who underwent 18 F-fluorodeoxyglucose (FDG) positron emission tomography (PET) (PET) before surgery were recruited. All of the breast cancers were invasive ductal carcinomas and ≥1 cm in size to exclude a partial volume effect. The maxSUV of breast cancers was compared with histopathologic and immunohistochemical findings. Additionally, the ability of PET to discriminate axillary nodal status (ANS) and correlation between ANS and tumor characteristics were evaluated. A high maxSUV of breast cancer was significantly correlated with the following poor prognosis factors: tumor invasiveness >2 cm (2.9 vs. 5.4; p 2 cm (p=0.046), LVIs (all of variables; p 2 cm, higher tumor grade, higher MIB-1, hormonal receptor negativity, and triple negativity. However, PET has a limited value in discriminating axillary lymph nodes. Pre-operative PET is a useful modality to predict biologic poor prognosis factors which could affect adjunctive therapy of breast cancer. (author)

  20. Implementation and application of simulation platform of PET based on GATE

    International Nuclear Information System (INIS)

    Zhang Bin; Zhao Shujun; Zhang Shixun; Liu Haojia

    2010-01-01

    Positron emission tomography (PET) is a tool for obtaining functional image in vivo and GATE is a dedicated software for PET/SPECT simulation based on Mentor Carlo Method. It encapsulates the Geant4 libraries to achieve a modular and provides a number of new characteristics. In practice, a simulation platform of PET has been builded employing GATE based on Ubuntu operating system, including many keys and skills in the process. We have exploited benchmark PET, a testing example in GATE, and implemented PET scanner simulation in the end. Through analyzing the simulation data, the result demonstrate that predictive goal has been reached. The work provides the foundation for investigating PET scanner and optimizing the algorithm of tomograph image reconstruction. (authors)

  1. PET and SPECT in neurology

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium). Dept. of Radiology and Nuclear Medicine; Vries, Erik F.J. de; Waarde, Aren van [Groningen University Medical Center (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Otte, Andreas (ed.) [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology

    2014-07-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  2. PET and SPECT in neurology

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Ghent Univ.; Vries, Erik F.J. de; Waarde, Aren van; Otte, Andreas

    2014-01-01

    PET and SPECT in Neurology highlights the combined expertise of renowned authors whose dedication to the investigation of neurological disorders through nuclear medicine technology has achieved international recognition. Classical neurodegenerative disorders are discussed as well as cerebrovascular disorders, brain tumors, epilepsy, head trauma, coma, sleeping disorders, and inflammatory and infectious diseases of the CNS. The latest results in nuclear brain imaging are detailed. Most chapters are written jointly by a clinical neurologist and a nuclear medicine specialist to ensure a multidisciplinary approach. This state-of-the-art compendium will be valuable to anybody in the field of neuroscience, from the neurologist and the radiologist/nuclear medicine specialist to the interested general practitioner and geriatrician. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences, the other volumes covering PET and SPECT in psychiatry and in neurobiological systems.

  3. The accuracy of {sup 18}F-FDG PET/CT in predicting the pathological response to neoadjuvant chemotherapy in patients with breast cancer. A meta-analysis and systematic review

    Energy Technology Data Exchange (ETDEWEB)

    Tian, Fangfang; Shen, Guohua; Diao, Wei; Jia, Zhiyun [West China Hospital of Sichuan University, Department of Nuclear Medicine, Chengdu, Sichuan (China); Deng, Yunfu [West China Hospital of Sichuan University, Department of Oncology, Chengdu (China)

    2017-11-15

    The aim of this meta-analysis was to evaluate the accuracy of {sup 18}F-FDG PET/CT in predicting the pathological response to neoadjuvant chemotherapy (NAC) in breast cancer (BC) patients. PubMed, Embase, the Cochrane Library (Central), and the Web of Science (SCI-Expanded) were systematically searched to identify pertinent studies. The methodologic quality of the included studies was assessed by the Quality Assessment of Diagnostic Accuracy Studies-2. The Spearman correlation coefficient was used to explore the existence of a threshold effect. Heterogeneity was assessed by the likelihood ratio I {sup 2} index. The pooled values calculated with a mixed-effects model for the sensitivity, specificity and diagnostic odds ratio with 95% confidence intervals were 81.9% (76.0-86.6%), 79.3% (72.1-85.1%) and 17.35 (10.98-27.42), respectively. {sup 18}F-FDG PET/CT has a moderate accuracy in predicting the pathological response during the early process of NAC in breast cancer patients. To increase the role of {sup 18}F-FDG PET/CT in monitoring the therapy response, future prospective studies are needed to explore how chemotherapy regimens and different subtypes affect the levels of glucose metabolism. (orig.)

  4. PET and SPECT in psychiatry

    International Nuclear Information System (INIS)

    Dierckx, Rudi A.J.O.; Otte, Andreas; Vries, Erik F.J. de; Waarde, Aren van

    2014-01-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  5. PET and SPECT in psychiatry

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Ghent Univ. (Belgium); Otte, Andreas [Univ. of Applied Sciences Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [University Medical Center Groningen (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-09-01

    Covers classical psychiatric disorders as well as other subjects such as suicide, sleep, eating disorders, and autism. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT in Psychiatry showcases the combined expertise of renowned authors whose dedication to the investigation of psychiatric disease through nuclear medicine technology has achieved international recognition. The classical psychiatric disorders as well as other subjects - such as suicide, sleep, eating disorders, and autism - are discussed and the latest results in functional neuroimaging are detailed. Most chapters are written jointly by a clinical psychiatrist and a nuclear medicine expert to ensure a multidisciplinary approach. This state of the art compendium will be valuable to all who have an interest in the field of neuroscience, from the psychiatrist and the radiologist/nuclear medicine specialist to the interested general practitioner and cognitive psychologist. It is the first volume of a trilogy on PET and SPECT imaging in the neurosciences; other volumes will focus on PET and SPECT in neurology and PET and SPECT of neurobiological systems.

  6. Importance of Attenuation Correction (AC) for Small Animal PET Imaging

    DEFF Research Database (Denmark)

    El Ali, Henrik H.; Bodholdt, Rasmus Poul; Jørgensen, Jesper Tranekjær

    2012-01-01

    was performed. Methods: Ten NMRI nude mice with subcutaneous implantation of human breast cancer cells (MCF-7) were scanned consecutively in small animal PET and CT scanners (MicroPETTM Focus 120 and ImTek’s MicroCATTM II). CT-based AC, PET-based AC and uniform AC methods were compared. Results: The activity...

  7. Corpus luteum mimics a pelvic lesion on FDG PET in women of childbearing age

    International Nuclear Information System (INIS)

    Kang, K.W.; Sim, J.S.

    2002-01-01

    Objectives: To find out the nature of incidental single pelvic lesion on F-18 FDG PET scan in the women of childbearing age, further investigation were done. Methods: Three women who had a single round hypermetabolic lesion in the pelvic cavity on FDG PET were further investigated through follow up PET scan or MRI scan. The purposes of PET scan were routine follow up of breast cancer after surgery and adjuvant chemotherapy for a patient and cancer screening for two women. The ages were 39, 45, and 48 years old respectively. The last menstrual periods (LMP) were 21, 22 and 24 days before PET examinations. The size and peak SUVs (standard uptake values) of lesions are presented. Results: The lesion in pelvic cavity disappeared in a patients with breast cancer on a follow up PET scan 2 months and 1 week later. The lesions in two women were proved to be corpus luteum cysts on MRI examination on the same day of PET examination. Conclusion: Single pelvic lesion in women of childbearing age should be ruled out a normal corpus luteum cyst. Also, schedule of PET imaging should be adjusted according to her menstrual period

  8. Dual-time FDG-PET/CT in patients with potential breast cancer recurrence: Head-to-head comparison with CT and bone scintigraphy

    DEFF Research Database (Denmark)

    Baun, Christina; Falch Braas, Kirsten; Gerke, Oke

    of six hours and had a blood glucose level less than 8 mmol/l prior to injection of 4 MBq/kg of FDG. Imaging was performed 1 and 3 hours (±5 mins) after injection. At both time-points a low-dose CT from the skull to the proximal femur was obtained followed by a 3D PET-scan of the same area. The duration...... administered with a flow of 3.0 ml/s and a delay of 60 seconds. Bone scintigraphy. The patients were injected with 700 MBq 99mTc-DPD 3 to 4 hours prior to whole body imaging. In the waiting period the patients were asked to drink approx. 1 litre of clear liquids. Positive findings with any of the three...... had sensitivities of 67% and 81% and specificities of 100% and 48%, respectively. Conclusion: These interim results suggest that FDG PET/CT may have a role in the diagnostic work-up of patients with suspected recurrent breast cancer. The 3-hour FDG-PET scan may be diagnostically superior to the other...

  9. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    International Nuclear Information System (INIS)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah

    2014-01-01

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after 18 F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast-enhanced PET

  10. Evaluation of Dixon Sequence on Hybrid PET/MR Compared with Contrast-Enhanced PET/CT for PET-Positive Lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, Ju Hye; Cho, Ihn Ho; Kong, Eun Jung; Chun, Kyung Ah [Yeungnam Univ. Hospital, Daegu (Korea, Republic of)

    2014-03-15

    Hybrid positron emission tomography and magnetic resonance (PET/MR) imaging performs a two-point Dixon MR sequence for attenuation correction. However, MR data in hybrid PET/MR should provide anatomic and morphologic information as well as an attenuation map. We evaluated the Dixon sequence of hybrid PET/MR for anatomic correlation of PET-positive lesions compared with contrast-enhanced PET/computed tomography (CT) in patients with oncologic diseases. Twelve patients underwent a single injection, dual imaging protocol. PET/CT was performed with an intravenous contrast agent (85±13 min after {sup 18}F-FDG injection of 403± 45 MBq) and then (125±19 min after injection) PET/MR was performed. Attenuation correction and anatomic allocation of PET were performed using contrast-enhanced CT for PET/CT and Dixon MR sequence for hybrid PET/MR. The Dixon MR sequence and contrast-enhanced CT were compared for anatomic correlation of PET-positive lesions (scoring scale ranging from 0 to 3 for visual ratings). Additionally, standardized uptake values (SUVs) for the detected lesions were assessed for quantitative comparison. Both hybrid PET/MR and contrast-enhanced PET/CT identified 55 lesions with increased FDG uptake in ten patients. In total, 28 lymph nodes, 11 bone lesions, 3 dermal nodules, 3 pleural thickening lesions, 2 thyroid nodules, 1 pancreas, 1 liver, 1 ovary, 1 uterus, 1 breast, 1 soft tissue and 2 lung lesions were present. The best performance was observed for anatomic correlation of PET findings by the contrast-enhanced CT scans (contrast-enhanced CT, 2.64± 0.70; in-phase, 1.29±1.01; opposed-phase, 1.29±1.15; water-weighted, 1.71±1.07; fat weighted, 0.56±1.03). A significant difference was observed between the scores obtained from the contrast-enhanced CT and all four coregistered Dixon MR images. Quantitative evaluation revealed a high correlation between the SUVs measured with hybrid PET/MR (SUVmean, 2.63±1.62; SUVmax, 4.30±2.88) and contrast

  11. The value of delayed 18F-FDG PET/CT imaging for differentiating axillary lymph nodes in breast cancer

    International Nuclear Information System (INIS)

    Ji, Young Sik; Son, Ju Cheol; Park, Cheol Woo

    2013-01-01

    Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. 18 F-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after 18 F-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean ± standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign

  12. Prognostic impact of {sup 18}F-FDG PET/CT staging and of pathological response to neoadjuvant chemotherapy in triple-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Groheux, D.; Merlet, P. [Saint-Louis Hospital, Department of Nuclear Medicine, Paris Cedex 10 (France); University of Paris VII, B2T Doctoral School, Institut Universitaire d' Hematologie, Paris (France); Giacchetti, S.; Hamy, A.S.; Espie, M. [Saint-Louis Hospital, Breast Diseases Unit, Department of Medical Oncology, Paris (France); Delord, M. [Institut Universitaire d' Hematologie, Department of Biostatistics and Bioinformatics, Paris (France); Roquancourt, A. de [Saint-Louis Hospital, Department of Pathology, Paris (France); Hindie, E. [University of Bordeaux, Department of Nuclear Medicine, Haut-Leveque Hospital, CHU Bordeaux, Bordeaux (France)

    2014-11-29

    Mortality is high in patients with locally advanced triple-negative breast cancer (TNBC), especially in those with residual tumour after neoadjuvant chemotherapy (NAC). The aim of this study was to determine if pretreatment {sup 18}F-FDG PET/CT staging and pathological findings after NAC could together allow stratification of patients into prognostic groups. Initial staging with {sup 18}F-FDG PET/CT was performed prospectively in 85 consecutive patients with stage II/III TNBC. Correlations between PET findings and disease-specific survival (DSS) were examined. In patients without distant metastases on PET staging, the impact of pathological response to NAC on DSS was examined. Patterns of recurrence were also analysed. {sup 18}F-DG PET/CT revealed distant metastases in 11 of 85 patients (12.9 %). Among 74 M0 patients, 23 (31.1 %) showed a pathological complete response (pCR) at surgery, while 51 had residual invasive disease (no pCR). DSS differed considerably among the three groups of patients (log-rank P <.001): among patients with occult metastases on baseline PET/CT, 2-year DSS was 18.2 %, and among patients without initial metastases on PET/CT, 5-year DSS was 61.3 % in patients without pCR after NAC and 95.2 % in those with pCR. Of the 51 patients who did not achieve pCR, 21 relapsed (17 developed distant metastases). The sites of distant recurrence were: lung/pleura (nine patients), brain (eight patients), liver (six patients), distant lymph nodes (six patients) and bone (five patients). In patients with clinical stage II/III TNBC, {sup 18}F-FDG PET/CT findings at initial staging and pathological response at the end of NAC allow three groups of patients with quite different prognoses to be defined. Extraskeletal recurrences predominated. Specific follow-up strategies in patients with TNBC who do not achieve pCR deserve investigation. (orig.)

  13. Correlation between {sup 18}F-FDG uptake on PET/CT and prognostic factors in triple-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Koo, Hye Ryoung [Seoul National University College of Medicine, Department of Radiology, 28 Yongon-dong, Chongno-gu, Seoul (Korea, Republic of); Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Park, Jeong Seon [Hanyang University College of Medicine, Department of Radiology, Seoul (Korea, Republic of); Kang, Keon Wook [Seoul National University College of Medicine, Department of Nuclear Medicine, Seoul (Korea, Republic of); Han, Wonshik [Seoul National University College of Medicine, Department of Surgery, Seoul (Korea, Republic of); Park, In Ae [Seoul National University College of Medicine, Department of Pathology, Seoul (Korea, Republic of); Moon, Woo Kyung [Seoul National University College of Medicine, Department of Radiology, 28 Yongon-dong, Chongno-gu, Seoul (Korea, Republic of)

    2015-11-15

    The purpose of this study was to investigate whether a correlation exists between {sup 18}F-fluorodeoxyglucose (FDG) uptake and prognostic factors in triple-negative breast cancer (TNBC). Between January 2009 and December 2013, 103 patients (mean age, 50.6 years) with primary TNBC (mean, 2.6 cm; range, 1.0-6.5 cm) underwent {sup 18}F-FDG PET/CT for initial staging. Correlations between maximum standardized uptake value (SUV{sub max}) on PET/CT and prognostic factors including tumour size, nodal status, histological grade, Ki-67 proliferation index, tumour suppressor p53, and 'basal-like' markers (epidermal growth factor receptor and CK 5/6) were assessed. The mean SUV{sub max} of the 103 tumours was 10.94 ± 5.25 (range: 2-32.8). There was a positive correlation between SUV{sub max} and Ki-67 (Spearman's rho = 0.29, P = 0.003) and tumour size (Spearman's rho = 0.27, P = 0.006), whereas this relationship was not observed in the nodal status, histological grade, p53 status and 'basal-like' phenotypes. In a multivariate regression analysis, Ki-67 (P < 0.001) and tumour size (P = 0.009) were significantly associated with SUV{sub max} in TNBCs. Increased {sup 18}F-FDG uptake on PET/CT was correlated with a high Ki-67 proliferation index and larger tumour size in TNBC. These results suggest a potential role of {sup 18}F-FDG PET/CT in identifying TNBC with more aggressive behaviour. (orig.)

  14. Fibrous dysplasia mimicking bone metastasis on both bone scintigraphy and 18F FDG PET CT: Diagnostic dilemma in a patient with breast cancer

    International Nuclear Information System (INIS)

    KC, Sud Hir Suman; Sharma, Punit; Singh, Har Man Deep; Bal, Chand Rasekhar; Kumar, Rake Sh

    2012-01-01

    Bone is the most common distant site to which breast cancer metastasizes. Commonly used imaging modalities for imaging bone metastasis are bone scintigraphy, plain radiography, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). Although bone scintigraphy gas high sensitivity for detecting bone metastasis, its specificity is low. This is because of the fact that bone scintigraphy images secondary changes in bone rather than just tumor cells 18 F fluorodeoxyglucose ( 18 F FDG) PET CT, on the other hand, directly images the tumor cells' glucose metabolism. Unfortunately, similar to bone scintigraphy, benign bone conditions can also show increased 18 F FDG uptake on PET CT, and PET positive asymptomatic fibrous dysplasia can be misinterpreted as a metastasis. Fibrous dysplasia of bone has wide skeletal distribution, with variability of 18 F FDG uptake and CT appearance. It is therefore important to recognize the characteristics of this skeletal dysplasia, to allow differentiation from skeletal metastasis. Bone lesions with 18 F FDG uptake need to be carefully interpreted when evaluating patients with known malignancy. In doubtful cases, fibrous dysplasia should be given as a differential diagnosis and histopathological diagnosis may be warranted, as highlighted in the present case

  15. Non-invasive breast biopsy method using GD-DTPA contrast enhanced MRI series and F-18-FDG PET/CT dynamic image series

    Science.gov (United States)

    Magri, Alphonso William

    This study was undertaken to develop a nonsurgical breast biopsy from Gd-DTPA Contrast Enhanced Magnetic Resonance (CE-MR) images and F-18-FDG PET/CT dynamic image series. A five-step process was developed to accomplish this. (1) Dynamic PET series were nonrigidly registered to the initial frame using a finite element method (FEM) based registration that requires fiducial skin markers to sample the displacement field between image frames. A commercial FEM package (ANSYS) was used for meshing and FEM calculations. Dynamic PET image series registrations were evaluated using similarity measurements SAVD and NCC. (2) Dynamic CE-MR series were nonrigidly registered to the initial frame using two registration methods: a multi-resolution free-form deformation (FFD) registration driven by normalized mutual information, and a FEM-based registration method. Dynamic CE-MR image series registrations were evaluated using similarity measurements, localization measurements, and qualitative comparison of motion artifacts. FFD registration was found to be superior to FEM-based registration. (3) Nonlinear curve fitting was performed for each voxel of the PET/CT volume of activity versus time, based on a realistic two-compartmental Patlak model. Three parameters for this model were fitted; two of them describe the activity levels in the blood and in the cellular compartment, while the third characterizes the washout rate of F-18-FDG from the cellular compartment. (4) Nonlinear curve fitting was performed for each voxel of the MR volume of signal intensity versus time, based on a realistic two-compartment Brix model. Three parameters for this model were fitted: rate of Gd exiting the compartment, representing the extracellular space of a lesion; rate of Gd exiting a blood compartment; and a parameter that characterizes the strength of signal intensities. Curve fitting used for PET/CT and MR series was accomplished by application of the Levenburg-Marquardt nonlinear regression

  16. Readout and characterisation of new silicon pixel photodiode array for use in PET

    International Nuclear Information System (INIS)

    Hooper, P.; Ward, G.; Lerch, R.; Rozenfeld, A.

    2002-01-01

    Full text: Positron emission tomography (PET) is a functional imaging tool, which is able to quantify physiological, and biochemical processes in vivo using short-lived cyclotron-produced radiotracers. The main physical principle of PET is the simultaneous measurement of two 511 keV photons which are emitted in opposite directions following the annihilation of a positron in tissue. The accuracy of tracking these photons determines the accuracy of localising the radiotracer in the body, which is referred to as the spatial resolution of the system. Compared with conventional single photon imaging with gamma cameras, PET provides superior spatial resolution and sensitivity. However, compared with anatomical imaging techniques, the spatial resolution remains relatively poor at approximately 4-6 mm full width at half maximum (FWHM), compared with 1 mm FWHM for MRI. The Centre for Medical Radiation Physics at the University of Wollongong is developing a new Positron Emission Tomography (PET) detection sub-module that will significantly improve the spatial resolution of PET. The new sub-module design is simple and robust to minimise module assembly complications and is completely independent of photomultiplier tubes. The new sub-module has also been designed to maximise its flexibility for easy sub-module coupling so as to form a complete, customised, detection module to be used in PET scanners dedicated to human brain and breast, and small animal studies. A new computer controlled gantry allows the system to be used for PET and SPECT applications. Silicon 8x8 detector arrays have been developed by CMRP and will be optically coupled scintillation crystals and readout using the VIKING tM hybrid preamplifier chip to form the basis of the new module Characterisation of the pixel photodiode array has been performed to check the uniformity of the response of the array. This characterisation has been done using a pulsed, near infra-red laser diode system and alpha particles

  17. Sequential 18F-FDG PET/CT for early prediction of complete pathological response in breast and axilla during neoadjuvant chemotherapy

    International Nuclear Information System (INIS)

    Koolen, Bas B.; Pengel, Kenneth E.; Wesseling, Jelle; Vogel, Wouter V.; Valdes Olmos, Renato A.; Vrancken Peeters, Marie-Jeanne T.F.D.; Rutgers, Emiel J.T.; Vincent, Andrew D.; Gilhuijs, Kenneth G.A.; Rodenhuis, Sjoerd

    2014-01-01

    To investigate the value of response monitoring in both the primary tumour and axillary nodes on sequential PET/CT scans during neoadjuvant chemotherapy (NAC) for predicting complete pathological response (pCR), taking the breast cancer subtype into account. In 107 consecutive patients 290 PET/CT scans were performed at baseline (PET/CT1, 107 patients), after 2 - 3 weeks of chemotherapy (PET/CT2, 85 patients), and after 6 - 8 weeks (PET/CT3, 98 patients). The relative changes in SUVmax (from baseline) of the tumour and the lymph nodes and in both combined (after logistic regression), and the changes in the highest SUVmax between scans (either tumour or lymph node) were determined and their associations with pCR of the tumour and lymph nodes after completion of NAC were assessed using receiver operating characteristic (ROC) analysis. A pCR was seen in 17 HER2-positive tumours (65 %), 1 ER-positive/HER2-negative tumour (2 %), and 16 triple-negative tumours (52 %). The areas under the ROC curves (ROC-AUC) for the prediction of pCR in HER2-positive tumours after 3 weeks were 0.61 for the relative change in tumours, 0.67 for the combined change in tumour and nodes, and 0.72 for the changes in the highest SUVmax between scans. After 8 weeks equivalent values were 0.59, 0.42 and 0.64, respectively. In triple-negative tumours the ROC-AUCs were 0.76, 0.84 and 0.76 after 2 weeks, and 0.87, 0.93 and 0.88 after 6 weeks, respectively. In triple-negative tumours a PET/CT scan after 6 weeks (three cycles) appears to be optimally predictive of pCR. In HER2-positive tumours neither a PET/CT scan after 3 weeks nor after 8 weeks seems to be useful. The changes in SUVmax of both the tumour and axillary nodes combined correlates best with pCR. (orig.)

  18. The maximum standardized uptake value of 18 F-FDG PET scan to determine prognosis of hormone-receptor positive metastatic breast cancer

    Directory of Open Access Journals (Sweden)

    Zhang Jian

    2013-01-01

    Full Text Available Abstract Background Whether PET scan maximum standard uptake value (SUVmax could differentiate luminal A from luminal B and help predict the survival of metastatic breast cancer (MBC patients with luminal subtype is still unknown and need to be investigated. Methods 305 MBC patients with luminal subtypes were screened with PET/CT. Eligible patients were prospectively followed up. Results In total, 134 patients were eligible for this study. SUVmax was significantly related to the number of metastatic sites and presence of visceral metastasis on univariate analysis. SUVmax could not effectively differentiate patients with luminal A from luminal B subtype. Although luminal subtype at diagnosis could predict the relapse-free interval, it could not predict progression-free survival (PFS or overall survival (OS after developing relapse. In contrast, SUVmax was predictive of both PFS and OS and this effect was maintained in multivariate COX regression model. Conclusions SUVmax of MBC did not correlate with molecular subtypes of primary tumor. While molecular subtype may be a valuable prognostic factor at primary diagnosis of breast cancer, the SUVmax, rather than molecular subtype, does have a potential to predict independently in multivariate analysis for the PFS and OS in patients with metastatic disease of luminal subtype.

  19. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Shao, Yiping; Sun, Xishan [University of Texas MD Anderson Cancer Center (United States); Lou, Kai [Rice University (United States)

    2015-05-18

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  20. Development of compact DOI-measurable PET detectors for simultaneous PET/MR Imaging

    International Nuclear Information System (INIS)

    Shao, Yiping; Sun, Xishan; Lou, Kai

    2015-01-01

    It is critically needed yet challenging to develop compact PET detectors with high sensitivity and uniform, high imaging resolution for improving the performance of simultaneous PET/MR imaging, particularly for an integrated/inserted small-bore system. Using the latest “edge-less” SiPM arrays for DOI measurement using the design of dual-ended-scintillator readout, we developed several compact PET detectors suited for PET/MR imaging. Each detector consists of one LYSO array with each end coupled to a SiPM array. Multiple detectors can be seamlessly tiled together along all sides to form a large detector panel. Detectors with 1.5x1.5 and 2.0x2.0 mm crystals at 20 or 30 mm lengths were studied. Readout of individual SiPM or capacitor-based signal multiplexing was used to transfer 3D interaction position-coded analog signals through flexible-print-circuit cables to dedicated ASIC frontend electronics to output digital timing pulses that encode interaction information. These digital pulses can be transferred to, through standard LVDS cables, and decoded by a FPGA-based data acquisition positioned outside the MRI scanner for coincidence event selection. Initial detector performance measurement shows excellent crystal identification even with 30 mm long crystals, ~18% and 2.8 ns energy and timing resolutions, and around 2-3 mm DOI resolution. A large size detector panel can be scaled up with these modular detectors and different PET systems can be flexibly configured with the scalable readout electronics and data acquisition, providing an important design advantage for different system and application requirements. It is expected that standard shielding of detectors, electronics and signal transfer lines can be applied for simultaneous PET/MR imaging applications, with desired DOI measurement capability to enhance the PET performance and image quality.

  1. The value of delayed {sup 18}F-FDG PET/CT imaging for differentiating axillary lymph nodes in breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ji, Young Sik; Son, Ju Cheol [Dept. of Nuclear Medicine, Dongnam Institute of Radiological and Medical Sciences Cancer Center, Busan (Korea, Republic of); Park, Cheol Woo [Dept. of Radiological Technology Dong-Eui Institute of Technology, Busan (Korea, Republic of)

    2013-12-15

    Positron emission tomography/computed tomography (PET/CT) imaging with fluorodeoxyglucose (FDG) have been used as a powerful fusion modality in nuclear medicine not only for detecting cancer but also for staging and therapy monitoring. Nevertheless, there are various causes of FDG uptake in normal and/or benign tissues. The purpose of present study was to investigate whether additional delayed imaging can improve the diagnosis to differentiate the rates of FDG uptake at axillary lymph nodes (ALN) between malignant and benign in breast cancer patients. 180 PET/CT images were obtained for 27 patients with ALN uptake. The patients who had radiotherapy and chemotherapy were excluded from the study. {sup 18}F-FDG PET/CT scan at 50 min (early phase) and 90 min (delayed phase) after {sup 18}F-FDG injection were included in this retrospective study. The staging of cancers was confirmed by final clinical according to radiologic follow-up and pathologic findings. The standardized uptake value (SUV) of ALN was measured at the Syngo Acquisition Workplace by Siemens. The 27 patients included 18 malignant and 9 ALN benign groups and the 18 malignant groups were classified into the 3 groups according to number of metastatic ALN in each patient. ALNs were categorized less than or equal 3 as N1, between 4 to 9 as N2 and more than 10 as N3 group. Results are expressed as the mean ± standard deviation (S.D.) and statistically analyzed by SPSS. As a result, Retention index (RI-SUV max) in metastasis was significantly higher than that in non-metastasis about 5 fold increased. On the other hand, RI-SUV max in N group tended to decrease gradually from N1 to N3. However, we could not prove significance statistically in malignant group with ANOVA. As a consequence, RI-SUV max was good indicator for differentiating ALN positive group from node negative group in breast cancer patients. These results show that dual-time-point scan appears to be useful in distinguishing malignant from benign.

  2. First-in-human uPAR PET: Imaging of Cancer Aggressiveness

    Science.gov (United States)

    Persson, Morten; Skovgaard, Dorthe; Brandt-Larsen, Malene; Christensen, Camilla; Madsen, Jacob; Nielsen, Carsten H.; Thurison, Tine; Klausen, Thomas Levin; Holm, Søren; Loft, Annika; Berthelsen, Anne Kiil; Ploug, Michael; Pappot, Helle; Brasso, Klaus; Kroman, Niels; Højgaard, Liselotte; Kjaer, Andreas

    2015-01-01

    A first-in-human clinical trial with Positron Emission Tomography (PET) imaging of the urokinase-type plasminogen activator receptor (uPAR) in patients with breast, prostate and bladder cancer, is described. uPAR is expressed in many types of human cancers and the expression is predictive of invasion, metastasis and indicates poor prognosis. uPAR PET imaging therefore holds promise to be a new and innovative method for improved cancer diagnosis, staging and individual risk stratification. The uPAR specific peptide AE105 was conjugated to the macrocyclic chelator DOTA and labeled with 64Cu for targeted molecular imaging with PET. The safety, pharmacokinetic, biodistribution profile and radiation dosimetry after a single intravenous dose of 64Cu-DOTA-AE105 were assessed by serial PET and computed tomography (CT) in 4 prostate, 3 breast and 3 bladder cancer patients. Safety assessment with laboratory blood screening tests was performed before and after PET ligand injection. In a subgroup of the patients, the in vivo stability of our targeted PET ligand was determined in collected blood and urine. No adverse or clinically detectable side effects in any of the 10 patients were found. The ligand exhibited good in vivo stability and fast clearance from plasma and tissue compartments by renal excretion. In addition, high uptake in both primary tumor lesions and lymph node metastases was seen and paralleled high uPAR expression in excised tumor tissue. Overall, this first-in-human study therefore provides promising evidence for safe use of 64Cu-DOTA-AE105 for uPAR PET imaging in cancer patients. PMID:26516369

  3. Simulation study comparing the helmet-chin PET with a cylindrical PET of the same number of detectors

    Science.gov (United States)

    Ahmed, Abdella M.; Tashima, Hideaki; Yoshida, Eiji; Nishikido, Fumihiko; Yamaya, Taiga

    2017-06-01

    There is a growing interest in developing brain PET scanners with high sensitivity and high spatial resolution for early diagnosis of neurodegenerative diseases and studies of brain functions. Sensitivity of the PET scanner can be improved by increasing the solid angle. However, conventional PET scanners are designed based on a cylindrical geometry, which may not be the most efficient design for brain imaging in terms of the balance between sensitivity and cost. We proposed a dedicated brain PET scanner based on a hemispheric shape detector and a chin detector (referred to as the helmet-chin PET), which is designed to maximize the solid angle by increasing the number of lines-of-response in the hemisphere. The parallax error, which PET scanners with a large solid angle tend to have, can be suppressed by the use of depth-of-interaction detectors. In this study, we carry out a realistic evaluation of the helmet-chin PET using Monte Carlo simulation based on the 4-layer GSO detector which consists of a 16  ×  16  ×  4 array of crystals with dimensions of 2.8  ×  2.8  ×  7.5 mm3. The purpose of this simulation is to show the gain in imaging performance of the helmet-chin PET compared with the cylindrical PET using the same number of detectors in each configuration. The sensitivity of the helmet-chin PET evaluated with a cylindrical phantom has a significant increase, especially at the top of the (field-of-view) FOV. The peak-NECR of the helmet-chin PET is 1.4 times higher compared to the cylindrical PET. The helmet-chin PET provides relatively low noise images throughout the FOV compared to the cylindrical PET which exhibits enhanced noise at the peripheral regions. The results show the helmet-chin PET can significantly improve the sensitivity and reduce the noise in the reconstructed images.

  4. Image-based Modeling of PSF Deformation with Application to Limited Angle PET Data

    Science.gov (United States)

    Matej, Samuel; Li, Yusheng; Panetta, Joseph; Karp, Joel S.; Surti, Suleman

    2016-01-01

    The point-spread-functions (PSFs) of reconstructed images can be deformed due to detector effects such as resolution blurring and parallax error, data acquisition geometry such as insufficient sampling or limited angular coverage in dual-panel PET systems, or reconstruction imperfections/simplifications. PSF deformation decreases quantitative accuracy and its spatial variation lowers consistency of lesion uptake measurement across the imaging field-of-view (FOV). This can be a significant problem with dual panel PET systems even when using TOF data and image reconstruction models of the detector and data acquisition process. To correct for the spatially variant reconstructed PSF distortions we propose to use an image-based resolution model (IRM) that includes such image PSF deformation effects. Originally the IRM was mostly used for approximating data resolution effects of standard PET systems with full angular coverage in a computationally efficient way, but recently it was also used to mitigate effects of simplified geometric projectors. Our work goes beyond this by including into the IRM reconstruction imperfections caused by combination of the limited angle, parallax errors, and any other (residual) deformation effects and testing it for challenging dual panel data with strongly asymmetric and variable PSF deformations. We applied and tested these concepts using simulated data based on our design for a dedicated breast imaging geometry (B-PET) consisting of dual-panel, time-of-flight (TOF) detectors. We compared two image-based resolution models; i) a simple spatially invariant approximation to PSF deformation, which captures only the general PSF shape through an elongated 3D Gaussian function, and ii) a spatially variant model using a Gaussian mixture model (GMM) to more accurately capture the asymmetric PSF shape in images reconstructed from data acquired with the B-PET scanner geometry. Results demonstrate that while both IRMs decrease the overall uptake

  5. Limits of Tumor Detectability in Nuclear Medicine and PET

    Directory of Open Access Journals (Sweden)

    Yusuf Emre Erdi

    2012-04-01

    Full Text Available Objective: Nuclear medicine is becoming increasingly important in the early detection of malignancy. The advantage of nuclear medicine over other imaging modalities is the high sensitivity of the gamma camera. Nuclear medicine counting equipment has the capability of detecting levels of radioactivity which exceed background levels by as little as 2.4 to 1. This translates to only a few hundred counts per minute on a regular gamma camera or as few as 3 counts per minute when using coincidence detection on a positron emission tomography (PET camera. Material and Methods: We have experimentally measured the limits of detectability using a set of hollow spheres in a Jaszczak phantom at various tumor-to-background ratios. Imaging modalities for this work were (1 planar, (2 SPECT, (3 PET, and (4 planar camera with coincidence detection capability (MCD. Results: When there is no background (infinite contrast activity present, the detectability of tumors is similar for PET and planar imaging. With the presence of the background activity , PET can detect objects in an order of magnitude smaller in size than that can be seen by conventional planar imaging especially in the typical clinical low (3:1 T/B ratios. The detection capability of the MCD camera lies between a conventional nuclear medicine (planar / SPECT scans and the detection capability of a dedicated PET scanner Conclusion: Among nuclear medicine’s armamentarium, PET is the closest modality to CT or MR imaging in terms of limits of detection. Modern clinical PET scanners have a resolution limit of 4 mm, corresponding to the detection of tumors with a volume of 0.2 ml (7 mm diameter in 5:1 T/B ratio. It is also possible to obtain better resolution limits with dedicated brain and animal scanners. The future holds promise in development of new detector materials, improved camera design, and new reconstruction algorithms which will improve sensitivity, resolution, contrast, and thereby further

  6. Prognostic relevance at 5 years of the early monitoring of neoadjuvant chemotherapy using 18F-FDG PET in luminal HER2-negative breast cancer

    International Nuclear Information System (INIS)

    Humbert, Olivier; Brunotte, Francois; Berriolo-Riedinger, Alina; Toubeau, Michel; Dygai-Cochet, Inna; Cochet, Alexandre; Gauthier, Melanie; Charon-Barra, Celine; Guiu, Severine; Desmoulins, Isabelle; Fumoleau, Pierre; Coutant, Charles

    2014-01-01

    The objective of this study was to evaluate, in the luminal human epidermal growth factor receptor 2 (HER2)-negative breast cancer subtype, the prognostic value of tumour glucose metabolism at baseline and of its early changes during neoadjuvant chemotherapy (NAC). This prospective study included 61 women with hormone-sensitive HER2-negative breast cancer treated with NAC. 18 F-Fluorodeoxyglucose (FDG) positron emission tomography (PET) was performed at baseline. Hepatic activity was used as a reference to distinguish between low metabolic and hypermetabolic tumours. In hypermetabolic tumours, a PET exam was repeated after the first course of NAC. The relative change in the maximum standardized uptake value of the tumour (∇SUV) was calculated. Nineteen women had low metabolic luminal breast cancers at baseline, correlated with low proliferation indexes. Forty-two women had hypermetabolic tumours, corresponding to more proliferative breast cancers with higher Ki-67 expression (p = 0.017) and higher grade (p = 0.04). The median follow-up period was 64.2 months (range 11.5-93.2). Thirteen women developed recurrent disease, nine of whom died. Worse overall survival was associated with larger tumour size [>5 cm, hazard ratio (HR) = 6.52, p = 0.009] and with hypermetabolic tumours achieving a low metabolic response after one cycle of NAC (ΔSUV < 16 %, HR = 10.63, p = 0.004). Five-year overall survival in these poor responder patients was 49.2 %. Overall survival in women with low metabolic tumours or hypermetabolic/good response tumours was 100 and 96.15 %, respectively. In luminal HER2-negative breast tumours, tumour metabolism at baseline and changes after the first course of NAC are early surrogate markers of patients' survival. A subgroup of women with hypermetabolic/poorly responding tumours, correlated with poor prognosis at 5 years, can be identified early. These results may guide future studies by tailoring the NAC regimen to the metabolic response. (orig.)

  7. Sequential {sup 18}F-FDG PET/CT for early prediction of complete pathological response in breast and axilla during neoadjuvant chemotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Koolen, Bas B. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Surgical Oncology, Amsterdam (Netherlands); Pengel, Kenneth E. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Radiology, Amsterdam (Netherlands); Wesseling, Jelle [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Pathology, Amsterdam (Netherlands); Vogel, Wouter V.; Valdes Olmos, Renato A. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Nuclear Medicine, Amsterdam (Netherlands); Vrancken Peeters, Marie-Jeanne T.F.D.; Rutgers, Emiel J.T. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Surgical Oncology, Amsterdam (Netherlands); Vincent, Andrew D. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Biometrics, Amsterdam (Netherlands); Gilhuijs, Kenneth G.A. [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Radiology, Amsterdam (Netherlands); University Medical Center Utrecht, Department of Radiology, Utrecht (Netherlands); Rodenhuis, Sjoerd [Netherlands Cancer Institute - Antoni van Leeuwenhoek Hospital, Department of Medical Oncology, Amsterdam (Netherlands)

    2014-01-15

    To investigate the value of response monitoring in both the primary tumour and axillary nodes on sequential PET/CT scans during neoadjuvant chemotherapy (NAC) for predicting complete pathological response (pCR), taking the breast cancer subtype into account. In 107 consecutive patients 290 PET/CT scans were performed at baseline (PET/CT1, 107 patients), after 2 - 3 weeks of chemotherapy (PET/CT2, 85 patients), and after 6 - 8 weeks (PET/CT3, 98 patients). The relative changes in SUVmax (from baseline) of the tumour and the lymph nodes and in both combined (after logistic regression), and the changes in the highest SUVmax between scans (either tumour or lymph node) were determined and their associations with pCR of the tumour and lymph nodes after completion of NAC were assessed using receiver operating characteristic (ROC) analysis. A pCR was seen in 17 HER2-positive tumours (65 %), 1 ER-positive/HER2-negative tumour (2 %), and 16 triple-negative tumours (52 %). The areas under the ROC curves (ROC-AUC) for the prediction of pCR in HER2-positive tumours after 3 weeks were 0.61 for the relative change in tumours, 0.67 for the combined change in tumour and nodes, and 0.72 for the changes in the highest SUVmax between scans. After 8 weeks equivalent values were 0.59, 0.42 and 0.64, respectively. In triple-negative tumours the ROC-AUCs were 0.76, 0.84 and 0.76 after 2 weeks, and 0.87, 0.93 and 0.88 after 6 weeks, respectively. In triple-negative tumours a PET/CT scan after 6 weeks (three cycles) appears to be optimally predictive of pCR. In HER2-positive tumours neither a PET/CT scan after 3 weeks nor after 8 weeks seems to be useful. The changes in SUVmax of both the tumour and axillary nodes combined correlates best with pCR. (orig.)

  8. Decreased occipital lobe metabolism by FDG-PET/CT

    Science.gov (United States)

    Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M.; Zan, Elcin; Javadi, Mehrbod S.; Venkatesan, Arun

    2017-01-01

    Objective: To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti–NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti–NMDA receptor neurologic disability groups. Methods: Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group–matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti–NMDA receptor and other definite AE patients as well as among patients with anti–NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. Results: The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti–NMDA receptor encephalitis and as a group (Z = −4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = −2.32, 1.46; p = 0.004). Among patients with anti–NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4–5 (lateral occipital lobe Z = −3.69, IQR 1; medial occipital lobe Z = −4.08, 1) compared with those with mRS 0–3 (lateral occipital lobe Z = −0.83, 2; p occipital lobe Z = −1.07, 2; p = 0.001). Conclusions: Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti–NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti–NMDA receptor encephalitis. PMID:29159205

  9. 2-[F-18] fluoro-2-deoxy-D-glucose (FDG) positron emission tomography (PET) in uncommon malignancies

    International Nuclear Information System (INIS)

    Nair, N.; Basu, S.

    2004-01-01

    This is a retrospective study with an aim to evaluate the clinical role of FDG-PET imaging in changing the decision making process or management strategies in patients with various uncommon malignancies or in malignancies where there is paucity of literature regarding application of PET at present. The study population consisted of a wide variety of various uncommon malignancies who were mainly referred from the neighboring Tata Memorial Hospital with few cases from the outside centers. Patients were fasting at least for 6 hours. Sixty minutes after injection of 370 MBq FDG, patients were imaged on the dedicated BGO based GE Advance PET scanner (General Electric Medical systems, Milwaukee, WI). Images were reconstructed using the attenuation weighted Ordered Subsets Expectation Maximization (OSEM) algorithm. Axial, coronal, sagittal and 3D images were visually interpreted and foci of increased tracer uptake were considered as disease involvement. The findings were compared lesion by lesion with other imaging procedures regarding staging, treatment response evaluation and residual disease evaluation. The malignancies selected for retrospective analysis, along with the number of cases are presented. 2 cases of chordoma were evaluated of which one had primary in the cervicodorsal region and came for PET evaluation post surgery and RT. PET showed metastatic foci in left axillary node, body of sacrum and right lower neck region in addition to the persistence of disease in the primary. The other was a case of petroclival chordoma came for disease evaluation post surgery. The MRI was inconclusive regarding persistence of residual disease and postoperative changes. PET scan was normal in the case. In a solitary case of operated Dermato-fibrosarcoma, PET revealed a hypermetabolic focus at one end of scar, subsequently proven as scar recurrence of the primary. 3 cases of skin adenexal tumour were evaluated, all of whom were upstaged by PET and changed the subsequent

  10. Technology challenges in small animal PET imaging

    International Nuclear Information System (INIS)

    Lecomte, Roger

    2004-01-01

    Positron Emission Tomography (PET) is a non-invasive nuclear imaging modality allowing biochemical processes to be investigated in vivo with sensitivity in the picomolar range. For this reason, PET has the potential to play a major role in the emerging field of molecular imaging by enabling the study of molecular pathways and genetic processes in living animals non-invasively. The challenge is to obtain a spatial resolution that is appropriate for rat and mouse imaging, the preferred animal models for research in biology, while achieving a sensitivity adequate for real-time measurement of rapid dynamic processes in vivo without violating tracer kinetic principles. An overview of the current state of development of dedicated small animal PET scanners is given, and selected applications are reported and discussed with respect to performance and significance to research in biology

  11. Clinical applications of positron emission tomography in breast cancer patients

    International Nuclear Information System (INIS)

    Roemer, W.; Avril, N.; Schwaiger, M.

    1997-01-01

    Increased glucose metabolism by malignant tissue can be visualized with positron emission tomography (PET), using the radiolabeled glucose analogue F-18 fluorodeoxyglucose (FDG). Depending on the criteria of image interpretation FDG-PET allows detection of breast cancer with a sensitivity of 68% to 94 % and a specificity of 84 % to 97 %. However, sensitivity to visualize small tumors (< 1 cm) is limited. Positron emission tomography demonstrates tumor involvement of regional lymph nodes with high accuracy, predominantly in patients with advanced breast cancer. The sensitivity for the detection of axillary lymph node metastases was 79% with a corresponding specificity of 96 %. Lymph node metastases could not be identified in four of six patients with small primary breast cancer (stage pT1), resulting in a sensitivity of only 33% in these patients. By visualizing primary tumors and metastases in one imaging procedure, PET imaging may allow the effective staging of breast cancer patients. Further studies are needed to define the role of scintigraphic techniques for the diagnostic work-up in patients. (author)

  12. Multi-modality PET-CT imaging of breast cancer in an animal model using nanoparticle x-ray contrast agent and 18F-FDG

    Science.gov (United States)

    Badea, C. T.; Ghaghada, K.; Espinosa, G.; Strong, L.; Annapragada, A.

    2011-03-01

    Multi-modality PET-CT imaging is playing an important role in the field of oncology. While PET imaging facilitates functional interrogation of tumor status, the use of CT imaging is primarily limited to anatomical reference. In an attempt to extract comprehensive information about tumor cells and its microenvironment, we used a nanoparticle xray contrast agent to image tumor vasculature and vessel 'leakiness' and 18F-FDG to investigate the metabolic status of tumor cells. In vivo PET/CT studies were performed in mice implanted with 4T1 mammary breast cancer cells.Early-phase micro-CT imaging enabled visualization 3D vascular architecture of the tumors whereas delayedphase micro-CT demonstrated highly permeable vessels as evident by nanoparticle accumulation within the tumor. Both imaging modalities demonstrated the presence of a necrotic core as indicated by a hypo-enhanced region in the center of the tumor. At early time-points, the CT-derived fractional blood volume did not correlate with 18F-FDG uptake. At delayed time-points, the tumor enhancement in 18F-FDG micro-PET images correlated with the delayed signal enhanced due to nanoparticle extravasation seen in CT images. The proposed hybrid imaging approach could be used to better understand tumor angiogenesis and to be the basis for monitoring and evaluating anti-angiogenic and nano-chemotherapies.

  13. Breast Cancer

    Science.gov (United States)

    ... right away. He or she will do a physical exam. They will ask you about your health history and your family’s history of breast cancer. ... and Wellness Staying Healthy Healthy Living Travel Occupational Health First Aid and ... Pets and Animals myhealthfinder Food and Nutrition Healthy Food ...

  14. Potential Use of American College of Radiology BI-RADS Mammography Atlas for Reporting and Assessing Lesions Detected on Dedicated Breast CT Imaging: Preliminary Study.

    Science.gov (United States)

    Jung, Hae Kyoung; Kuzmiak, Cherie M; Kim, Keum Won; Choi, Na Mi; Kim, Hye Jeong; Langman, Eun Lee; Yoon, Sora; Steen, Doreen; Zeng, Donglin; Gao, Fei

    2017-11-01

    Dedicated breast computed tomography (DBCT) is an emerging and promising modality for breast lesions. The objective of this study was to evaluate the potential use of applying the BI-RADS Mammography Atlas 5th Edition for reporting and assessing breast lesions on DBCT. Currently, no atlas exists for DBCT. Four radiologists trained in breast imaging were recruited in this institutional review board-approved, Health Insurance Portability and Accountability Act-compliant study. The enrolled radiologists, who were blinded to mammographic and histopathologic findings, individually reviewed 30 randomized DBCT cases that contained marked lesions. Thirty-four lesions were included in this study: 24 (70.6%) masses, 7 (20.6%) calcifications, and 3 (8.8%) architectural distortions. Eight (23.5%) lesions were malignant and 26 (76.5%) were benign. The reader was asked to specify according to the BI-RADS Mammography Atlas for each marked DBCT lesion: primary findings, features, breast density, and final assessment. We calculated readers' diagnostic performances for differentiating between benign and malignant lesions and interobserver variability for reporting and assessing lesions using a generalized estimating equation and the Fleiss kappa (κ) statistic. The estimated overall sensitivity of the readers was 0.969, and the specificity was 0.529. There were no significant differences in the sensitivity and the specificity between lesion types. For reporting the presence of a primary finding, the overall substantial agreement (κ = 0.70) was seen. In assigning the breast density and the final assessment, the overall agreement was moderate (κ = 0.53) and fair (κ = 0.30). The use of the BI-RADS Mammography Atlas 5th Edition for DBCT showed high performance and good agreement among readers. Copyright © 2017 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Tumor metabolism and perfusion ratio assessed by 18F-FDG PET/CT and DCE-MRI in breast cancer patients: Correlation with tumor subtype and histologic prognostic factors

    Energy Technology Data Exchange (ETDEWEB)

    An, Young-Sil [Department of Nuclear Medicine and Molecular Imaging, Ajou University School of Medicine (Korea, Republic of); Kang, Doo Kyoung [Department of Radiology, Ajou University School of Medicine (Korea, Republic of); Jung, Yong Sik; Han, Sehwan [Department of Surgery, Ajou University School of Medicine (Korea, Republic of); Kim, Tae Hee, E-mail: medhand@ajou.ac.kr [Department of Radiology, Ajou University School of Medicine (Korea, Republic of)

    2015-07-15

    Highlights: • In non-triple negative breast cancer, metabolic parameter (SUVmax) was significantly correlated with perfusion parameters (Kep and Ve). • In triple negative cancers, any perfusion parameters did not correlated with metabolic parameters. • Higher SUVmax, higher SUVmax/Ktrans, higher MTV50/Ktrans, higher TLG50/Ktrans, higher TLG50/Ve ratios were significantly correlated with TNBC. • In triple negative breast cancer, perfusion and metabolic parameters are not significantly correlated. • Triple negative breast cancer showed higher metabolic–perfusion ratios compared to non-triple negative breast cancer. - Abstract: Objective: Our purpose was to evaluate whether breast cancer with high metabolic–perfusion ratio would be associated with poor histopathologic prognostic factors and whether triple negative breast cancer (TNBC) would show high metabolic–perfusion ratio compared to non-triple negative breast cancer (non-TNBC). Methods: From March 2011 to November 2011, 67 females with invasive ductal carcinoma of breast who underwent both MRI and 18F-FDG PET/CT were included. Perfusion parameters including Ktrans, Kep and Ve were acquired from Dynamic contrast-enhanced magnetic resonance imaging (DCE-MRI). Metabolic parameters including the standardized uptake value (SUV) and volumetric metabolic parameters including metabolic tumor volume (MTV) and total lesion glycolysis (TLG) were obtained from F-18 fluorodeoxyglucose positron emission tomography/computed tomography (FDG PET/CT). Results: In non-TNBC, SUVmax was significantly correlated with Kep (ρ = 0.298, p = 0.036) and Ve (ρ = −0.286, p = 0.044). In TNBC, there was no significant correlation between all perfusion and metabolic parameters. Compared to non-TNBC, higher SUVmax (10.2 vs 5.3, p < 0.001), higher SUVmax/Ktrans (56.02 vs 20.3, p < 0.001), higher MTV50/Ktrans (7.8 vs 16.54, p < 0.001), higher TLG50/Ktrans (36.49 vs 12.3, p < 0.001), higher TLG50/Ve (91.34 vs 27.1 p = 0.022) were

  16. Development of baby cyclotron for PET in Korea

    International Nuclear Information System (INIS)

    Chai, J.S.; Kim, Y.S.; Hu, J.Y.; Shin, Y.C.; Yoon, M.H.

    2001-01-01

    Development of a 13 MeV cyclotron for Positron Emission Tomography (PET) has been in progress since April 1999 at the Korea Cancer Center Hospital (KCCH). The study has been carried out in a joint collaboration between KCCH and the Pohang University of Science and Technology (POSTECH). Increasing desire for an uninterrupted, reliable and timely supply of the isotopes to customers has prompted obtaining a dedicated 5-13 MeV cyclotron for PET applications and pursuing the purchase of another 30MeV medical cyclotron in the very near future. A decision has been made to design the PET cyclotron in Korea. This will not only ease the problems associated with maintenance during operation but also keep the door open for continuous upgrading of the machine in the future

  17. Fourier rebinning and consistency equations for time-of-flight PET planograms

    International Nuclear Information System (INIS)

    Li, Yusheng; Matej, Samuel; Metzler, Scott D; Defrise, Michel

    2016-01-01

    Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John’s equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations (FCEs) and the Fourier–John equation (FJE), which are the duals of the consistency equations and John’s equation, respectively. We then solve the FCEs and FJE using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms. Finally, we give

  18. Fourier rebinning and consistency equations for time-of-flight PET planograms.

    Science.gov (United States)

    Li, Yusheng; Defrise, Michel; Matej, Samuel; Metzler, Scott D

    2016-01-01

    Due to the unique geometry, dual-panel PET scanners have many advantages in dedicated breast imaging and on-board imaging applications since the compact scanners can be combined with other imaging and treatment modalities. The major challenges of dual-panel PET imaging are the limited-angle problem and data truncation, which can cause artifacts due to incomplete data sampling. The time-of-flight (TOF) information can be a promising solution to reduce these artifacts. The TOF planogram is the native data format for dual-panel TOF PET scanners, and the non-TOF planogram is the 3D extension of linogram. The TOF planograms is five-dimensional while the objects are three-dimensional, and there are two degrees of redundancy. In this paper, we derive consistency equations and Fourier-based rebinning algorithms to provide a complete understanding of the rich structure of the fully 3D TOF planograms. We first derive two consistency equations and John's equation for 3D TOF planograms. By taking the Fourier transforms, we obtain two Fourier consistency equations and the Fourier-John equation, which are the duals of the consistency equations and John's equation, respectively. We then solve the Fourier consistency equations and Fourier-John equation using the method of characteristics. The two degrees of entangled redundancy of the 3D TOF data can be explicitly elicited and exploited by the solutions along the characteristic curves. As the special cases of the general solutions, we obtain Fourier rebinning and consistency equations (FORCEs), and thus we obtain a complete scheme to convert among different types of PET planograms: 3D TOF, 3D non-TOF, 2D TOF and 2D non-TOF planograms. The FORCEs can be used as Fourier-based rebinning algorithms for TOF-PET data reduction, inverse rebinnings for designing fast projectors, or consistency conditions for estimating missing data. As a byproduct, we show the two consistency equations are necessary and sufficient for 3D TOF planograms

  19. Fibrous dysplasia mimicking bone metastasis on both bone scintigraphy and {sup 18}F FDG PET CT: Diagnostic dilemma in a patient with breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    KC, Sud Hir Suman; Sharma, Punit; Singh, Har Man Deep; Bal, Chand Rasekhar; Kumar, Rake Sh [India Institute of Medical Sciences, New Delhi (India)

    2012-12-15

    Bone is the most common distant site to which breast cancer metastasizes. Commonly used imaging modalities for imaging bone metastasis are bone scintigraphy, plain radiography, computed tomography (CT), magnetic resonance imaging (MRI), and positron emission tomography (PET). Although bone scintigraphy gas high sensitivity for detecting bone metastasis, its specificity is low. This is because of the fact that bone scintigraphy images secondary changes in bone rather than just tumor cells {sup 18}F fluorodeoxyglucose ({sup 18}F FDG) PET CT, on the other hand, directly images the tumor cells' glucose metabolism. Unfortunately, similar to bone scintigraphy, benign bone conditions can also show increased {sup 18}F FDG uptake on PET CT, and PET positive asymptomatic fibrous dysplasia can be misinterpreted as a metastasis. Fibrous dysplasia of bone has wide skeletal distribution, with variability of {sup 18}F FDG uptake and CT appearance. It is therefore important to recognize the characteristics of this skeletal dysplasia, to allow differentiation from skeletal metastasis. Bone lesions with {sup 18}F FDG uptake need to be carefully interpreted when evaluating patients with known malignancy. In doubtful cases, fibrous dysplasia should be given as a differential diagnosis and histopathological diagnosis may be warranted, as highlighted in the present case.

  20. Prognostic relevance at 5 years of the early monitoring of neoadjuvant chemotherapy using {sup 18}F-FDG PET in luminal HER2-negative breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Humbert, Olivier; Brunotte, Francois [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); CHU Le Bocage, Imaging Department, Dijon (France); Universite de Bourgogne, UMR CNRS 5158, Dijon (France); Berriolo-Riedinger, Alina; Toubeau, Michel; Dygai-Cochet, Inna [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); Cochet, Alexandre [Centre GF Leclerc, Department of Nuclear Medicine, Dijon (France); Universite de Bourgogne, UMR CNRS 5158, Dijon (France); Gauthier, Melanie [Centre GF Leclerc, Biostatistics and Quality of Life Unit, EA 4184, Dijon (France); Charon-Barra, Celine [Centre GF Leclerc, Department of Pathology, Dijon (France); Guiu, Severine; Desmoulins, Isabelle; Fumoleau, Pierre [Centre GF Leclerc, Department of Medical Oncology, Dijon (France); Coutant, Charles [Centre GF Leclerc, Department of Surgery, Dijon (France)

    2014-03-15

    The objective of this study was to evaluate, in the luminal human epidermal growth factor receptor 2 (HER2)-negative breast cancer subtype, the prognostic value of tumour glucose metabolism at baseline and of its early changes during neoadjuvant chemotherapy (NAC). This prospective study included 61 women with hormone-sensitive HER2-negative breast cancer treated with NAC. {sup 18}F-Fluorodeoxyglucose (FDG) positron emission tomography (PET) was performed at baseline. Hepatic activity was used as a reference to distinguish between low metabolic and hypermetabolic tumours. In hypermetabolic tumours, a PET exam was repeated after the first course of NAC. The relative change in the maximum standardized uptake value of the tumour (∇SUV) was calculated. Nineteen women had low metabolic luminal breast cancers at baseline, correlated with low proliferation indexes. Forty-two women had hypermetabolic tumours, corresponding to more proliferative breast cancers with higher Ki-67 expression (p = 0.017) and higher grade (p = 0.04). The median follow-up period was 64.2 months (range 11.5-93.2). Thirteen women developed recurrent disease, nine of whom died. Worse overall survival was associated with larger tumour size [>5 cm, hazard ratio (HR) = 6.52, p = 0.009] and with hypermetabolic tumours achieving a low metabolic response after one cycle of NAC (ΔSUV < 16 %, HR = 10.63, p = 0.004). Five-year overall survival in these poor responder patients was 49.2 %. Overall survival in women with low metabolic tumours or hypermetabolic/good response tumours was 100 and 96.15 %, respectively. In luminal HER2-negative breast tumours, tumour metabolism at baseline and changes after the first course of NAC are early surrogate markers of patients' survival. A subgroup of women with hypermetabolic/poorly responding tumours, correlated with poor prognosis at 5 years, can be identified early. These results may guide future studies by tailoring the NAC regimen to the metabolic response

  1. PET and SPECT of neurobiological systems

    Energy Technology Data Exchange (ETDEWEB)

    Dierckx, Rudi A.J.O. [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging; Gent Univ. (Belgium). Dept. of Nuclear Medicine; Otte, Andreas [Univ. of Applied Sciences, Offenburg (Germany). Faculty of Electrical Engineering and Information Technology; Vries, Erik F.J. de; Waarde, Aren van (eds.) [Groningen Univ. (Netherlands). Dept. of Nuclear Medicine and Molecular Imaging

    2014-04-01

    Addresses a variety of aspects of neurotransmission in the brain. Details the latest results in probe development. Emphasis on a multidisciplinary approach. Written by internationally acclaimed experts. PET and SPECT of Neurobiological Systems combines the expertise of renowned authors whose dedication to the development of novel probes and techniques for the investigation of neurobiological systems has achieved international recognition. Various aspects of neurotransmission in the brain are discussed, such as visualization and quantification of (more than 20 different) neuroreceptors, neuroinflammatory markers, transporters, and enzymes as well as neurotransmitter synthesis, ?-amyloid deposition, cerebral blood flow, and the metabolic rate of glucose. The latest results in probe development are also detailed. Most chapters are written jointly by radiochemists and nuclear medicine specialists to ensure a multidisciplinary approach. This state of the art compendium will be valuable to anyone in the field of clinical or preclinical neuroscience, from the radiochemist and radiologist/nuclear medicine specialist to the interested neurobiologist and general practitioner. It is the second volume of a trilogy on PET and SPECT imaging in the neurosciences. Other volumes focus on PET and SPECT in psychiatry and PET and SPECT in neurology''.

  2. 18F-FDG PET/CT in detection of gynecomastia in patients with hepatocellular carcinoma.

    Science.gov (United States)

    Wang, Hsin-Yi; Jeng, Long-Bin; Lin, Ming-Chia; Chao, Chih-Hao; Lin, Wan-Yu; Kao, Chia-Hung

    2013-01-01

    We retrospectively investigate the prevalence of gynecomastia as false-positive 2-[18F]fluoro-2-deoxy-d-glucose (18F-FDG) positron emission tomography (PET)/computed tomography (CT) imaging in patients with hepatocellular carcinoma (HCC). Among the 127 male HCC patients who underwent 18F-FDG PET/CT scan, the 18FDG uptakes at the bilateral breasts in 9 patients with gynecomastia were recorded as standard uptake value (SUVmax) and the visual interpretation in both early and delayed images. The mean early SUVmax was 1.58/1.57 (right/left breast) in nine gynecomastia patients. The three patients with early visual score of 3 had higher early SUVmaxs. Gynecomastia is a possible cause of false-positive uptake on 18F-FDG PET/CT images. Copyright © 2013 Elsevier Inc. All rights reserved.

  3. ImmunoPET of tissue factor expression in triple-negative breast cancer with a radiolabeled antibody Fab fragment

    International Nuclear Information System (INIS)

    Shi, Sixiang; Hong, Hao; Orbay, Hakan; Yang, Yunan; Ohman, Jakob D.; Graves, Stephen A.; Nickles, Robert J.; Liu, Bai; Wong, Hing C.; Cai, Weibo

    2015-01-01

    To date, there is no effective therapy for triple-negative breast cancer (TNBC), which has a dismal clinical outcome. Upregulation of tissue factor (TF) expression leads to increased patient morbidity and mortality in many solid tumor types, including TNBC. Our goal was to employ the Fab fragment of ALT-836, a chimeric anti-human TF mAb, for PET imaging of TNBC, which can be used to guide future TNBC therapy. ALT-836-Fab was generated by enzymatic papain digestion. SDS-PAGE and FACS studies were performed to evaluate the integrity and TF binding affinity of ALT-836-Fab before NOTA conjugation and 64 Cu-labeling. Serial PET imaging and biodistribution studies were carried out to evaluate the tumor targeting efficacy and pharmacokinetics in the MDA-MB-231 TNBC model, which expresses high levels of TF on the tumor cells. Blocking studies, histological assessment, as well as RT-PCR were performed to confirm TF specificity of 64 Cu-NOTA-ALT-836-Fab. ALT-836-Fab was produced with high purity, which exhibited superb TF binding affinity and specificity. Serial PET imaging revealed rapid and persistent tumor uptake of 64 Cu-NOTA-ALT-836-Fab (5.1 ± 0.5 %ID/g at 24 h post-injection; n = 4) and high tumor/muscle ratio (7.0 ± 1.2 at 24 h post-injection; n = 4), several-fold higher than that of the blocking group and tumor models that do not express significant level of TF, which was confirmed by biodistribution studies. TF specificity of the tracer was also validated by histology and RT-PCR. 64 Cu-NOTA-ALT-836-Fab exhibited prominent tissue factor targeting efficiency in MDA-MB-231 TNBC model. The use of a Fab fragment led to fast tumor uptake and good tissue/muscle ratio, which may be translated into same-day immunoPET imaging in the clinical setting to improve TNBC patient management. (orig.)

  4. ImmunoPET of tissue factor expression in triple-negative breast cancer with a radiolabeled antibody Fab fragment.

    Science.gov (United States)

    Shi, Sixiang; Hong, Hao; Orbay, Hakan; Graves, Stephen A; Yang, Yunan; Ohman, Jakob D; Liu, Bai; Nickles, Robert J; Wong, Hing C; Cai, Weibo

    2015-07-01

    To date, there is no effective therapy for triple-negative breast cancer (TNBC), which has a dismal clinical outcome. Upregulation of tissue factor (TF) expression leads to increased patient morbidity and mortality in many solid tumor types, including TNBC. Our goal was to employ the Fab fragment of ALT-836, a chimeric anti-human TF mAb, for PET imaging of TNBC, which can be used to guide future TNBC therapy. ALT-836-Fab was generated by enzymatic papain digestion. SDS-PAGE and FACS studies were performed to evaluate the integrity and TF binding affinity of ALT-836-Fab before NOTA conjugation and (64)Cu-labeling. Serial PET imaging and biodistribution studies were carried out to evaluate the tumor targeting efficacy and pharmacokinetics in the MDA-MB-231 TNBC model, which expresses high levels of TF on the tumor cells. Blocking studies, histological assessment, as well as RT-PCR were performed to confirm TF specificity of (64)Cu-NOTA-ALT-836-Fab. ALT-836-Fab was produced with high purity, which exhibited superb TF binding affinity and specificity. Serial PET imaging revealed rapid and persistent tumor uptake of (64)Cu-NOTA-ALT-836-Fab (5.1 ± 0.5 %ID/g at 24 h post-injection; n = 4) and high tumor/muscle ratio (7.0 ± 1.2 at 24 h post-injection; n = 4), several-fold higher than that of the blocking group and tumor models that do not express significant level of TF, which was confirmed by biodistribution studies. TF specificity of the tracer was also validated by histology and RT-PCR. (64)Cu-NOTA-ALT-836-Fab exhibited prominent tissue factor targeting efficiency in MDA-MB-231 TNBC model. The use of a Fab fragment led to fast tumor uptake and good tissue/muscle ratio, which may be translated into same-day immunoPET imaging in the clinical setting to improve TNBC patient management.

  5. ImmunoPET of tissue factor expression in triple-negative breast cancer with a radiolabeled antibody Fab fragment

    Energy Technology Data Exchange (ETDEWEB)

    Shi, Sixiang [University of Wisconsin, Materials Science Program, Madison, WI (United States); Hong, Hao; Orbay, Hakan; Yang, Yunan; Ohman, Jakob D. [University of Wisconsin, Department of Radiology, Madison, WI (United States); Graves, Stephen A.; Nickles, Robert J. [University of Wisconsin, Department of Medical Physics, Madison, WI (United States); Liu, Bai; Wong, Hing C. [Altor BioScience, Miramar, FL (United States); Cai, Weibo [University of Wisconsin, Materials Science Program, Madison, WI (United States); University of Wisconsin, Department of Radiology, Madison, WI (United States); University of Wisconsin, Department of Medical Physics, Madison, WI (United States); University of Wisconsin Carbone Cancer Center, Madison, WI (United States); University of Wisconsin, Departments of Radiology and Medical Physics, Madison, WI (United States)

    2015-07-15

    To date, there is no effective therapy for triple-negative breast cancer (TNBC), which has a dismal clinical outcome. Upregulation of tissue factor (TF) expression leads to increased patient morbidity and mortality in many solid tumor types, including TNBC. Our goal was to employ the Fab fragment of ALT-836, a chimeric anti-human TF mAb, for PET imaging of TNBC, which can be used to guide future TNBC therapy. ALT-836-Fab was generated by enzymatic papain digestion. SDS-PAGE and FACS studies were performed to evaluate the integrity and TF binding affinity of ALT-836-Fab before NOTA conjugation and {sup 64}Cu-labeling. Serial PET imaging and biodistribution studies were carried out to evaluate the tumor targeting efficacy and pharmacokinetics in the MDA-MB-231 TNBC model, which expresses high levels of TF on the tumor cells. Blocking studies, histological assessment, as well as RT-PCR were performed to confirm TF specificity of {sup 64}Cu-NOTA-ALT-836-Fab. ALT-836-Fab was produced with high purity, which exhibited superb TF binding affinity and specificity. Serial PET imaging revealed rapid and persistent tumor uptake of {sup 64}Cu-NOTA-ALT-836-Fab (5.1 ± 0.5 %ID/g at 24 h post-injection; n = 4) and high tumor/muscle ratio (7.0 ± 1.2 at 24 h post-injection; n = 4), several-fold higher than that of the blocking group and tumor models that do not express significant level of TF, which was confirmed by biodistribution studies. TF specificity of the tracer was also validated by histology and RT-PCR. {sup 64}Cu-NOTA-ALT-836-Fab exhibited prominent tissue factor targeting efficiency in MDA-MB-231 TNBC model. The use of a Fab fragment led to fast tumor uptake and good tissue/muscle ratio, which may be translated into same-day immunoPET imaging in the clinical setting to improve TNBC patient management. (orig.)

  6. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    Energy Technology Data Exchange (ETDEWEB)

    Thomas, C. M., E-mail: christopher.thomas@gstt.nhs.uk; Convery, D. J.; Greener, A. G. [Guy' s and St. Thomas’ NHS Foundation Trust, Medical Physics Department, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Pike, L. C.; Baker, S.; Woods, E. [Division of Imaging Sciences and Biomedical Engineering, King' s College London, King' s Health Partners, St. Thomas’ Hospital, London SE1 7EH (United Kingdom); Hartill, C. E. [Guy' s and St. Thomas’ NHS Foundation Trust, Radiotherapy, Clinical Outpatients Clinic, St. Thomas’ Hospital, London SE1 7EH (United Kingdom)

    2014-04-15

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway.

  7. Specific recommendations for accurate and direct use of PET-CT in PET guided radiotherapy for head and neck sites

    International Nuclear Information System (INIS)

    Thomas, C. M.; Convery, D. J.; Greener, A. G.; Pike, L. C.; Baker, S.; Woods, E.; Hartill, C. E.

    2014-01-01

    techniques, laser positioning may affect setup accuracy and couch deflection may be greater than scanners dedicated to radiotherapy. The full set of departmental commissioning and routine quality assurance tests applied to radiotherapy CT simulators must be carried out on the PET-CT scanner. CT image quality must be optimized for radiotherapy planning whilst understanding that the appearance will differ between scanners and may affect delineation. PET-CT quality assurance schedules will need to be added to and modified to incorporate radiotherapy quality assurance. Methods of working for radiotherapy and PET staff will change to take into account considerations of both parties. PET to CT alignment must be subject to quality control on a loaded and unloaded couch preferably using a suitable emission phantom, and tested throughout the whole data pathway. Data integrity must be tested throughout the whole pathway and a system included to verify that delineated structures are transferred correctly. Excellent multidisciplinary team communication and working is vital, and key staff members on both sides should be specifically dedicated to the project. Patient pathway should be clearly devised to optimize patient care and the resources of all departments. Recruitment of a cohort of patients into a methodology study is valuable to test the quality assurance methods and pathway

  8. Monte Carlo modeling of a clinical PET scanner by using the GATE dedicated computer code; Modelagem Monte Carlo de um PET Scanner clinico utilizando o codigo dedicado GATE

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Igor Fagner; Lima, Fernando Roberto de Andrade, E-mail: falima@cnen.gov.b [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Universidade de Pernambuco (UPE), Recife, PE (Brazil). Escola Politecnica; Vieira, Jose Wilson [Universidade Federal de Pernambuco (DEN/UFPE), Recife, PE (Brazil). Dept. de Energia Nuclear; Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil)

    2011-10-26

    This paper demonstrates more possible detailed the GATE simulated architecture involved in the 4D modeling of a General Electric PET scanner, the Advance. So, it were used data present in the literature on the configuration of GE modelled PET. The obtained results which were the 3D components of PET creation, and the simulation of 4D phenomena as the source decay and the gantry whirl, exhibit the potential of tool in emission tomograph modelling

  9. A basic study on lesion detectability for hot spot imaging of positron emitters with dedicated PET and positron coincidence gamma camera

    International Nuclear Information System (INIS)

    Zhang, Hong; Inoue, Tomio; Tian, Mei; Alyafei, Saleh; Oriuchi, Noboru; Khan, Nasim; Endo, Keigo; Li Sijin

    2001-01-01

    The aim of this study was to explore the correlations of detectability and the semi-quantification for hot spot imaging with positron emitters in positron emission tomography (PET) and with a positron coincidence detection system (PCD). Phantom study results for the measurement of the lesion-to-background (L/B) ratio ranged from 2.0 to 30.3, and detectability for hot spot lesion of PET and PCD were performed to correspond to clinical conditions. The detectability and semi-quantitative evaluation of hot spots from 4.4 mm to 36.9 mm in diameter were performed from the PET and PCD images. There were strong correlations between the L/B ratios derived from PET and PCD hot spot images and actual L/B ratios; but the L/B ratio derived from PET was higher than that from PCD with a significant difference of 10% to 54.8%. The detectability of hot spot imaging of PCD was lower than that of PET at 64.8% (PCD) versus 77.8% (PET). Even the actual L/B ratio was 8.0, hot spots more than 10.6 mm in diameter could be clearly identified with PCD imaging. The same identification could be achieved with PET imaging even when the actual L/B ratio was 4.0. This detailed investigation indicated that FDG PCD yielded results comparable to FDG PET on visual analysis and semi-quantitative analysis in detecting hot spots in phantoms, but semi-quantitative analysis of the L/B ratio with FDG PCD was inferior to that with FDG PET and the detectability of PCD in smaller hot spots was significantly poor. (author)

  10. Positron Emission Tomography/Magnetic Resonance Imaging for Local Tumor Staging in Patients With Primary Breast Cancer: A Comparison With Positron Emission Tomography/Computed Tomography and Magnetic Resonance Imaging.

    Science.gov (United States)

    Grueneisen, Johannes; Nagarajah, James; Buchbender, Christian; Hoffmann, Oliver; Schaarschmidt, Benedikt Michael; Poeppel, Thorsten; Forsting, Michael; Quick, Harald H; Umutlu, Lale; Kinner, Sonja

    2015-08-01

    This study aimed to assess the diagnostic performance of integrated positron emission tomography (PET)/magnetic resonance imaging (MRI) of the breast for lesion detection and local tumor staging of patients with primary breast cancer in comparison to PET/computed tomography (CT) and MRI. The study was approved by the local institutional review board. Forty-nine patients with biopsy-proven invasive breast cancer were prospectively enrolled in our study. All patients underwent a PET/CT, and subsequently, a contrast-enhanced PET/MRI of the breast after written informed consent was obtained before each examination. Two radiologists independently evaluated the corresponding data sets (PET/CT, PET/MRI, and MRI) and were instructed to identify primary tumors lesions as well as multifocal/multicentric and bilateral disease. Furthermore, the occurrence of lymph node metastases was assessed, and the T-stage for each patient was determined. Histopathological verification of the local tumor extent and the axillary lymph node status was available for 30 of 49 and 48 of 49 patients, respectively. For the remaining patients, a consensus characterization was performed for the determination of the T-stage and nodal status, taking into account the results of clinical staging, PET/CT, and PET/MRI examinations. Statistical analysis was performed to test for differences in diagnostic performance between the different imaging procedures. P values less than 0.05 were considered to be statistically significant. Positron emission tomography/MRI and MRI correctly identified 47 (96%) of the 49 patients with primary breast cancer, whereas PET/CT enabled detection of 46 (94%) of 49 breast cancer patients and missed a synchronous carcinoma in the contralateral breast in 1 patient. In a lesion-by-lesion analysis, no significant differences could be obtained between the 3 imaging procedures for the identification of primary breast cancer lesions (P > 0.05). Positron emission tomography/MRI and

  11. Coincidence detection FDG-PET (Co-PET) in the management of oncological patients: attenuation correction versus non-attenuation correction

    International Nuclear Information System (INIS)

    Chan, W.L.; Freund, J.; Pocock, N.; Szeto, E.; Chan, F.; Sorensen, B.; McBride, B.

    2000-01-01

    Full text: This study was to determine if attenuation correction (AC) in FDG Co-PET improved image quality, lesion detection, patient staging and management of various malignant neoplasms, compared to non-attenuation-corrected (NAC) images. Thirty patients (25 men, 5 women, mean age 58 years) with known or suspected malignant neoplasms, including non-small-cell lung cancer, non Hodgkin's and Hodgkin's lymphoma, carcinoma of the breast, head and neck cancer and melanoma, underwent FDG Co-PET, which was correlated with histopathology, CT and other conventional imaging modalities and clinical follow-up. Whole body tomography was performed (ADAC Vertex MCD) 60 min after 200 MBq of 18 F-FDG (>6h fasting). The number and location of FDG avid lesions detected on the AC images and NAC Co-PET images were blindly assessed by two independent observers. Semi-quantitative grading of image clarity and lesion-to-background quality was performed. This revealed markedly improved image clarity and lesion-to-background quality, in the AC versus NAC images. AC and NAC Co-PET were statistically different in relation to lesion detection (p<0.01) and tumour staging (p<0.0 1). NAC Co-PET demonstrated 51 of the 65 lesions (78%) detected by AC Co-PET. AC Co-PET staging was correct in 27 patients (90%), compared with NAC Co-PET in 22 patients (73%). AC Co-PET altered tumour staging in five of 30 patients (16%) and NAC Co-PET did not alter tumour staging in any of the patients- management was altered in only two of these five patients (7%). In conclusion, AC Co-PET resulted in better image quality with significantly improved lesion detectability and tumour staging compared to NAC Co-PET. Its additional impact on patient management in this relatively small sample was minor. Copyright (2000) The Australian and New Zealand Society of Nuclear Medicine Inc

  12. False Positive Uptake in Bilateral Gynecomastia on 68Ga-PSMA PET/CT Scan.

    Science.gov (United States)

    Sasikumar, Arun; Joy, Ajith; Nair, Bindu P; Pillai, M R A; Madhavan, Jayaprakash

    2017-09-01

    A 66-year-old man on hormonal therapy with prostate cancer was referred for Ga-PSMA PET/CT scan for biochemical recurrence. Ga-PSMA PET/CT scan detected moderate heterogeneous tracer concentration in bilateral breast parenchyma, in addition to the abnormal tracer concentration in enlarged prostate gland, right external iliac lymph node, and sclerotic lesion in L4 vertebra. On clinical examination, he was found to have bilateral gynecomastia. Abnormal concentration of Ga-PSMA in breast cancer is now well known, and in this context, it is important to know that tracer localization can occur in gynecomastia as well, as evidenced in this case.

  13. The potential of multiparametric MRI of the breast

    Science.gov (United States)

    Pinker, Katja; Helbich, Thomas H

    2017-01-01

    MRI is an essential tool in breast imaging, with multiple established indications. Dynamic contrast-enhanced MRI (DCE-MRI) is the backbone of any breast MRI protocol and has an excellent sensitivity and good specificity for breast cancer diagnosis. DCE-MRI provides high-resolution morphological information, as well as some functional information about neoangiogenesis as a tumour-specific feature. To overcome limitations in specificity, several other functional MRI parameters have been investigated and the application of these combined parameters is defined as multiparametric MRI (mpMRI) of the breast. MpMRI of the breast can be performed at different field strengths (1.5–7 T) and includes both established (diffusion-weighted imaging, MR spectroscopic imaging) and novel MRI parameters (sodium imaging, chemical exchange saturation transfer imaging, blood oxygen level-dependent MRI), as well as hybrid imaging with positron emission tomography (PET)/MRI and different radiotracers. Available data suggest that multiparametric imaging using different functional MRI and PET parameters can provide detailed information about the underlying oncogenic processes of cancer development and progression and can provide additional specificity. This article will review the current and emerging functional parameters for mpMRI of the breast for improved diagnostic accuracy in breast cancer. PMID:27805423

  14. Evaluation of treatment response for breast cancer: are we entering the era of "biological complete remission"?

    Institute of Scientific and Technical Information of China (English)

    Li Bian; Tao Wang; Yi Liu; Hui-Qiang Zhang; Jin-Jie Song; Shao-Hua Zhang; Shi-Kai Wu; San-Tai Song; Ze-Fei Jiang

    2012-01-01

    Breast cancer is one of the most common malignancies in women.The post-operative recurrence and metastasis are the leading causes of breast cancer-related mortality.In this study,we tried to explore the role of circulating tumor cell (CTC) detection combination PET/CT technology evaluating the prognosis and treatment response of patients with breast cancer; meanwhile,we attempted to assess the concept of "biological complete remission" (bCR) in this regard.A 56-year-old patient with breast cancer (T2N1M1,stage Ⅳ left breast cancer,with metastasis to axillary lymph nodes and lungs) received 6 cycles of salvage treatment with albumin-bound paclitaxel plus capecitabine and trastuzumab.Then,she underwent CTC detection and PET/CT for efficacy evaluation.CTC detection combination PET/CT is useful for the evaluation of the biological efficacy of therapies for breast cancer.The bCR of the patient appeared earlier than the conventional clinical imaging complete remission and promised the histological (pathological) complete remission.The integrated application of the concepts including bCR,imageological CR,and histological CR can achieve the early and accurate assessment of biological therapeutic reponse and prognosis of breast cancer.

  15. The effection of nuclear medicine in the diagnosis and treat of breast cancer

    International Nuclear Information System (INIS)

    Wang Xiuling; Hou Xiancun; Xu Kai

    2006-01-01

    The incidence of breast cancer has been increasing recently. Nuclear Medicine plays an important role in the diagnosis and treat of breast cancer: breast scintigraphy in the diagnosis of breast cancer, the detection of sentinel lymph node using radioisotope, skeleton scintigraphy in the diagnosis of osseous metastasis, the application of PET in breast cancer, for instance. (authors)

  16. Skeletal metastases from breast cancer: uptake of 18F-fluoride measured with positron emission tomography in correlation with CT

    International Nuclear Information System (INIS)

    Petren-Mallmin, M.; Andreasson, I.; Bergh, J.; Ljunggren, Oe.; Ahlstroem, H.; Antoni, G.; Laangstroem, B.; Bergstroem, M.

    1998-01-01

    Objective. To characterise the uptake of 18 F in skeletal metastases from breast cancer using positron emission tomography (PET) and to relate these findings to the appearance on CT. Patients and design. PET with 18 F and CT were performed in five patients with multiple skeletal metastases from breast cancer. The CT characteristics were analysed in areas with high uptake on the PET study. Dynamic PET imaging of the skeletal kinetics of the 18 F-fluoride ion were included. Results. The areas of abnormal high accumulation of 18 F correlated well with the pathological appearance on CT. Lytic as well as sclerotic lesions had markedly higher uptake than normal bone, with a 5-10 times higher transport rate constant for trapping of the tracer in the metastatic lesions than in normal bone. Conclusion. PET with 18 F-fluoride demonstrates very high uptake in lytic and sclerotic breast cancer metastases. (orig.)

  17. Current status and future perspective of PET

    International Nuclear Information System (INIS)

    Lee, Myung Chul

    2002-01-01

    Positron Emission Tomography (PET) is a nuclear medicine imaging modality that consists of systemic administration to a subject of a radiopharmaceutical labeled with a positron-emitting radionuclide. Following administration, its distribution in the organ or structure under study can be assessed as a function of time and space by (1) detecting the annihilation radiation resulting from the interaction of the positrons with matter, and (2) reconstructing the distribution of the radioactivity from a series of that used in computed tomography (CT). The nuclides most generally exhibit chemical properties that render them particularly desirable in physiological studies. The radionuclides most widely used in PET are F-18, C-11, O-15 and N-13. Regarding to the number of the current PET Centers worldwide (based on ICP data), more than 300 PET Centers were in operation in 2000. The use of PET technology grew rapidly compared to that in 1992 and 1996, particularly in the USA, which demonstrates a three-fold rise in PET installations. In 2001, 194 PET Centers were operating in the USA. In 1994, two clinical and research-oriented PET Centers at Seoul National University Hospital and Samsung Medical Center, was established as the first dedicated PET and Cyclotron machines in Korea, followed by two more PET facilities at the Korea Cancer Center Hospital, Ajou Medical Center, Yonsei University Medical Center, National Cancer Center and established their PET Center. Catholic Medical School and Pusan National University Hospital have finalized a plan to install PET machine in 2002, which results in total of nine PET Centers in Korea. Considering annual trends of PET application in four major PET centers in Korea in Asan Medical Center recent six years (from 1995 to 2000), a total of 11,564 patients have been studied every year and the number of PET studies has shown steep growth year upon year. We had, 1,020 PET patients in 1995. This number increased to 1,196, 1,756, 2,379, 3

  18. 78 FR 61805 - National Breast Cancer Awareness Month, 2013

    Science.gov (United States)

    2013-10-04

    ... National Breast Cancer Awareness Month, 2013 By the President of the United States of America A... from it. As we observe National Breast Cancer Awareness Month, we salute the women and men who dedicate... October 2013 as National Breast Cancer Awareness Month. I encourage citizens, government agencies, private...

  19. Brain {sup 18}F-FDG PET-MRI co registration: iconographic essay;PET-RM neurologico com FDG-{sup 18}F: ensaio iconografico

    Energy Technology Data Exchange (ETDEWEB)

    Cavalcanti Filho, Jose Leite Gondim; Machado Neto, Luiz de Souza, E-mail: leite_jose@yahoo.co [Multi Imagem PET, Rio de Janeiro, RJ (Brazil); Fonseca, Lea Mirian Barbosa da; Gasparetto, Emerson Leandro [Universidade Federal do Rio de Janeiro (UFRJ), RJ (Brazil); Domingues, Romeu Cortes; Domingues, Roberto Cortes [Clinica de Diagnostico por Imagem (CDPI), Rio de Janeiro, RJ (Brazil)

    2010-05-15

    The combination of positron emission tomography (PET) with magnetic resonance imaging (MRI) has been the subject of several studies in recent years. Positron emission tomography is the most sensitive and specific imaging modality in the detection of metabolic changes, but presents limited spatial resolution. On the other hand, MRI presents a significant spatial resolution, besides evaluating soft tissues signal intensity with excellent contrast resolution. The present iconographic essay is aimed at demonstrating the potential clinical application of PET/MRI co registration. The studies were performed in a dedicated PET unit with {sup 18}F-fluorodeoxyglucose (FDG) as radiopharmaceutical and co registered with 1.5 T or 3 T brain MRI. The brain images fusion software presents an already well-established accuracy, so a significant synergy between a functional PET study and an excellent MRI anatomical detail is achieved. The most attractive clinical applications of this approach are the following: epileptogenic zone assessment in patients refractory to drug therapy, identification of patients with cognitive impairment at higher risk for progression to dementia and differentiation of dementias and Parkinsonian syndromes. (author)

  20. Malignant phyllodes tumor of the breast metastasizing to the vulva: {sup 18}F FDG PET CT Demonstrating rare metastasis from a rare tumor

    Energy Technology Data Exchange (ETDEWEB)

    Khangembam, Bang Kim Chand Ra; Sharma, Punit; Singla, Su Has; Singhal, Abinav; Dhull, Varun Singh; Bal, Chand Rasek Har; Kumar, Rakesh [All India Institute of Medical Sciences, New Delhi (India)

    2012-09-15

    Phyllodes tumors are extremely rare fibroepithelial neoplasms accounting for 0.3 to 0.5% of all female breast tumors with an incidence of 2.1 per 1 million women. They are classified histologically into benign, borderline and malignant varieties. The majority of them are benign, with only 25% being malignant. Surgery remains the mainstay of treatment. One characteristic is that although the malignant variety tends to metastasize and recur, the benign form has also been found to behave in a similar manner. Benign phyllodes tumor has a 21% risk of local recurrence, while that of the malignant variety ranges from 20 to 32%. In patients with malignant phyllodes tumor, the rate of distant metastases ranges from 25 to 40%. The most frequent sites of distant metastasis is uncommon as this tumor spreads by hematogeneous route. Other sites for distant metastasis have been reported sporadically, including the duodenum, pancreas, brain, nasal cavity, forearm, parotid, skin, oral cavity, skeletal muscle, mandible and maxilla. We present a rare case of recurrent malignant phyllodes tumor with metastasis to the vulva, which has not been reported in the literature to the best of our knowledge. A 49 year old female who had undergone lumpectomy and locoregional radiotherapy 1 year previously for malignant phyllodes tumor of the right breast presented with difficulty in breathing and cervical lymphadenopathy. Chest X ray showed multiple pulmonary nodules suggestive of metastasis. She was referred for restaging with 18F fluorodeoxyglucose (FDG)positron emission tomography computed tomography (PET CT)FDG PET CT. Maximum intensity projection (MIP)PET images revealed multiple FDG avid enlarged cervical lymph nodes, bilateral pulmonary nodules along with left pleural effusion and extensive bone marrow metastases. The interesting finding was an intensely FDG avid (SUV{sup max}-21.4)subcutaneous soft tissue density lesion (measuring 2.0x2.2x2.0cm)in the vulva, which was later proved to be

  1. Human dosimetry and preliminary tumor distribution of 18F-fluoropaclitaxel in healthy volunteers and newly diagnosed breast cancer patients using PET/CT.

    Science.gov (United States)

    Kurdziel, Karen A; Kalen, Joseph D; Hirsch, Jerry I; Wilson, John D; Bear, Harry D; Logan, Jean; McCumisky, James; Moorman-Sykes, Kathy; Adler, Stephen; Choyke, Peter L

    2011-09-01

    (18)F-fluoropaclitaxel is a radiolabeled form of paclitaxel, a widely used chemotherapy agent. Preclinical data suggest that (18)F-fluoropaclitaxel may be a reasonable surrogate for measuring the uptake of paclitaxel. As a substrate of P-glycoprotein, a drug efflux pump associated with multidrug resistance, (18)F-fluoropaclitaxel may also be useful in identifying multidrug resistance and predicting tumor response for drugs other than paclitaxel. After informed consent was obtained, 3 healthy volunteers and 3 patients with untreated breast cancer (neoadjuvant chemotherapy candidates, tumor size > 2 cm) received an intravenous infusion of (18)F-fluoropaclitaxel and then underwent PET/CT. Healthy volunteers underwent serial whole-body imaging over an approximately 3-h interval, and organ (18)F residence times were determined from the time-activity curves uncorrected for decay to determine dosimetry. Radiation dose estimates were calculated using OLINDA/EXM software. For breast cancer patients, dynamic imaging of the primary tumor was performed for 60 min, followed by static whole-body scans at 1 and 2 h after injection. Dosimetry calculations showed that the gallbladder received the highest dose (229.50 μGy/MBq [0.849 rad/mCi]), followed by the small and large intestines (161.26 μGy/MBq [0.597 rad/mCi] and 184.59 μGy/MBq [0.683 rad/mCi]). The resultant effective dose was 28.79 μGy/MBq (0.107 rem/mCi). At approximately 1 h after injection, an average of 42% of the decay-corrected activity was in the gastrointestinal system, with a mean of 0.01% in the tumor. All 3 breast cancer patients showed retention of (18)F-fluoropaclitaxel and ultimately demonstrated a complete pathologic response (no invasive cancer in the breast or axillary nodes) to chemotherapy that included a taxane (either paclitaxel or docetaxel) at surgical resection. The tumor-to-background ratio increased with time to a maximum of 7.7 at 20 min. This study demonstrates the feasibility of using (18)F

  2. Human Dosimetry and Preliminary Tumor Distribution of 18F-Fluoropaclitaxel in Healthy Volunteers and Newly Diagnosed Breast Cancer Patients Using PET/CT

    International Nuclear Information System (INIS)

    Kurdziel, K.A.; Logan, J.; Kalen, J.D.; Hirsch, J.I.; Wilson, J.D.; Bear, H.D.; McCumisky, J.; Moorman-Sykes, K.; Adler, S.; Choyke, P.L.

    2011-01-01

    18 F-fluoropaclitaxel is a radiolabeled form of paclitaxel, a widely used chemotherapy agent. Preclinical data suggest that 18 F-fluoropaclitaxel may be a reasonable surrogate for measuring the uptake of paclitaxel. As a substrate of P-glycoprotein, a drug efflux pump associated with multidrug resistance, 18 F-fluoropaclitaxel may also be useful in identifying multidrug resistance and predicting tumor response for drugs other than paclitaxel. After informed consent was obtained, 3 healthy volunteers and 3 patients with untreated breast cancer (neoadjuvant chemotherapy candidates, tumor size > 2 cm) received an intravenous infusion of 18 F-fluoropaclitaxel and then underwent PET/CT. Healthy volunteers underwent serial whole-body imaging over an approximately 3-h interval, and organ 18 F residence times were determined from the time-activity curves uncorrected for decay to determine dosimetry. Radiation dose estimates were calculated using OLINDA/EXM software. For breast cancer patients, dynamic imaging of the primary tumor was performed for 60 min, followed by static whole-body scans at 1 and 2 h after injection. Dosimetry calculations showed that the gallbladder received the highest dose (229.50 μGy/MBq [0.849 rad/mCi]), followed by the small and large intestines (161.26 μGy/MBq [0.597 rad/mCi] and 184.59 μGy/MBq [0.683 rad/mCi]). The resultant effective dose was 28.79 μGy/MBq (0.107 rem/mCi). At approximately 1 h after injection, an average of 42% of the decay-corrected activity was in the gastrointestinal system, with a mean of 0.01% in the tumor. All 3 breast cancer patients showed retention of 18 F-fluoropaclitaxel and ultimately demonstrated a complete pathologic response (no invasive cancer in the breast or axillary nodes) to chemotherapy that included a taxane (either paclitaxel or docetaxel) at surgical resection. The tumor-to-background ratio increased with time to a maximum of 7.7 at 20 min. This study demonstrates the feasibility of using 18 F

  3. Automated radiochemical processing for clinical PET

    International Nuclear Information System (INIS)

    Padgett, H.C.; Schmidt, D.G.; Bida, G.T.; Wieland, B.W.; Pekrul, E.; Kingsbury, W.G.

    1991-01-01

    With the recent emergence of positron emission tomography (PET) as a viable clinical tool, there is a need for a convenient, cost-effective source of the positron emitter-labeled radiotracers labeled with carbon-11, nitrogen-13, oxygen-15, and fluorine-18. These short-lived radioisotopes are accelerator produced and thus, require a cyclotron and radiochemistry processing instrumentation that can be operated 3 in a clinical environment by competant technicians. The basic goal is to ensure safety and reliability while setting new standards for economy and ease of operation. The Siemens Radioisotope Delivery System (RDS 112) is a fully automated system dedicated to the production and delivery of positron-emitter labeled precursors and radiochemicals required to support a clinical PET imaging program. Thus, the entire RDS can be thought of as an automated radiochemical processing apparatus

  4. Comparative analysis of multi-slice spiral CT and positron emission tomography-CT in evaluation of axillary lymph nodes in breast cancer patients

    International Nuclear Information System (INIS)

    Sun Xianchang; Zhang Ruyi; Liu Qingwei; Zhao Suhong; Zu Degui; Li Xin

    2008-01-01

    Objective: To evaluate and compare spiral CT and positron emission tomography-CT (PET-CT) in characterization of of axillary lymph nodes in breast cancer patients. Methods: Forty patients with pathologically proven breast cancer underwent contrast-enhanced spiral CT of the breast and axilla, 13 of them also underwent PET-CT examination. One hundred and fifty-eight axillary lymph nodes were found in the 40 patients through contrast enhanced spiral CT, while 57 lymph nodes were found in the 13 patients through PET-CT. Three radiologists rated the lymph nodes found in CT images on a five-point scale. If the score was equal to or greater than 3, it was defined as positive (metastatic), otherwise negative. Visual observation and semiquantitative analysis were used to classify lymph nodes in PET-CT images. The results of spiral CT observation and PET-CT observation of lymph nodes were compared with pathological results. The relative value of CT and PET-CT was analyzed. Exact probability statistics were employed. Results: One hundred and fifty eight lymph nodes of 40 patients were detected by spiral CT, 91 of them were diagnosed as positive and 67 as negative Among the lymph nodes found in spiral CT, 99 were positive and 59 were negative pathologicall. A total of 57 lymph nodes were found by PET-CT. Thirty-nine of them were defined as positive and 18 as negative. Among the lymph nodes found in PET-CT, 39 were positive and 18 were negative pathologically. The sensitivity, specificity, accuracy, positive and negative predictive values in CT prediction in axillary lymph nodes metastases were 88.89%, 94.91%, 91.14%, 96.70%, and 83.58%, respectively. The sensitivity, specificity, accuracy, positive and negative predictive values in PET-CT prediction in axillary lymph nodes metastases were 97.44%, 94.44%, 96.49%, 97.44%, and 94.44%, respectively. PET-CT had no significant difference with spiral CT in sensitivity, accuracy, positive and negative predictive values for detection

  5. Basal (18)F-FDG PET/CT as a predictive biomarker of tumor response for neoadjuvant therapy in breast cancer.

    Science.gov (United States)

    García Vicente, A M; Soriano Castrejón, A; Pruneda-González, R E; Fernández Calvo, G; Muñoz Sánchez, M M; Álvarez Cabellos, R; Espinosa Aunión, R; Relea Calatayud, F

    2016-01-01

    To explore the relation between tumor kinetic assessed by (18)F-FDG PET and final neoadjuvant chemotherapy (NC) response within a molecular phenotype perspective. Prospective study included 144 women with breast cancer. All patients underwent a dual-time point (18)F-FDG PET/CT previous to NC. The retention index (RI), between SUV-1 and SUV-2 was calculated. Molecular subtypes were re-grouped in low, intermediate and high-risk biological phenotypes. After NC, all residual primary tumor specimens were histopathologically classified in tumor regression grades (TRG) and response groups. The relation between SUV-1, SUV-2 and RI with the TRG and response groups was evaluated in all molecular subtypes and in accordance with the risk categories. Responder's lesions showed significant greater SUVmax compared to non-responders. The RI value did not show any significant relation with response. Attending to molecular phenotypes, statistical differences were observed with greater SUV for responders having high-risk molecular subtypes. Glycolytic tumor characteristics showed a significant correlation with NC response and dependence of risk phenotype. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  6. Potential Biomarker of L type Amino Acid Transporter 1 in Breast Cancer Progression

    International Nuclear Information System (INIS)

    Liang, Zhongxing; Cho, Heidi T.; Williams, Larry; Zhu, Aizhi; Liang, Ke; Huang, Ke; Wu, Hui; Jiang, Chunsu; Hong, Samuel; Crowe, Ronald; Goodman, Mark M.; Shim, Hyunsuk

    2011-01-01

    L type amino acid transporter 1 (LAT1) is essential for the transport of large neutral amino acids. However, its role in breast cancer growth remains largely unknown. The purpose of the study is to investigate whether LAT1 is a potential biomarker for the diagnosis and treatment of breast cancer. LAT1 mRNA and protein levels in breast cancer cell lines and tissues were analyzed. In addition, the effects of targeting LAT1 for the inhibition of breast cancer cell tumorigenesis were assessed with soft agar assay. The imaging of xenograft with 1 amino 3 [ 18F ]fluorocyclo butane 1 carboxylic acid ([ 18F ]FACBC) PET was assessed for its diagnostic biomarker potential. Normal breast tissue or low malignant cell lines expressed low levels of LAT1 mRNA and protein, while highly malignant cancer cell lines and high grade breast cancer tissue expressed high levels of LAT1. In addition, higher expression levels of LAT1 in breast cancer tissues were consistent with advanced stage breast cancer. Furtermore, the blockade of LAT1 with its inhibitor, 2 amino bicyclo[2.2.1]heptane 2 carboxylic acid (BCH), or the knockdown of LAT1 with siRNA, inhibited proliferation and tumorigenesis of breast cancer cells. A leucine analog, [ 18F ]FACBC, has been demonstrated to be an excellent PET tracer for the non invasive imaging og malignant breast cancer using an orthotopic animal model. The overexpression of LAT1 is required for the progression of breast cancer. LAT1 represents a potential biomarker for therapy and diagnosis of breast cancer. [ 18F ]FACBC that correlates with LAT1 function is a potential PET tracer for malignant breast tumor imaging

  7. [18F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    International Nuclear Information System (INIS)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale; Ruhlmann, Verena; Buderath, Paul; Aktas, Bahriye; Heusch, Philipp; Kraff, Oliver

    2015-01-01

    To evaluate the diagnostic potential of PET/MRI with [ 18 F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [ 18 F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  8. Acquiring additional delayed PET images improves sensitivity and specificity in oncology cases

    International Nuclear Information System (INIS)

    Lamki, L.M.; Barron, B.J.; Mullani, N.; Joseph, U.; Ehert, E.

    2002-01-01

    Aim: This study looked into utility of acquiring PET images at 2-3 hours in addition to the standard whole body PET done at 1-hour after FDG injection in certain oncology cases. The objective is to evaluate whether the delayed additional images can decipher equivocal foci of FDG accumulation commonly seen in oncology patients. Typical example is the bowel activity that moves with time. Materials and Methods: PET protocol at our Institution in patients with colon Cancer, Pancreas Ca, Ovarian Ca and Breast Ca include a whole body PET (6-7 bed positions) done at 1-hour after 15 mCi F-18-FDG followed by select limited area PET scan (typically 2 bed stops over the area of interest) at 2-3 hours. Acquisition was undertaken on Siemens ECAT-EXACT Camera - 2-D acquisition and 8 mins. per bed position (5 mins. Emission and 3 mins. Transmission), 16.3 cm FOV and then Iterative Reconstruction. Results: Analysis of the first 115 patients who had additional delayed images resulted in 80% of patients where delayed images helped in interpretation. In 70% of these, delayed images helped in identifying physiological structures, e.g., ureters, bowel, blood vessels and muscles versus pathology. In 25%, they actually helped in identifying malignancy, e.g. more definite FDG accumulation. Almost all helped to boost the confidence of the reader. The contribution was mainly in differentiating bowel and ureter activity from cancer in the abdomen, as these change position with time. In case of pancreas and breast cancer, delayed images contributed in clarifying tumor metabolic activity as well. Inflammation and motion artifacts could also be better defined and so was muscle uptake. Conclusion: (1) Additional delayed PET imaging is very helpful in certain cancers in identifying more lesions and avoiding pitfalls. (2) They can yield higher sensitivity and specificity for colon, ovarian, breast and pancreas cancers. (3) Identification of physiologic structures and differentiation of these from

  9. Positron emission tomography (PET) and magnetic resonance imaging (MRI) for the assessment of axillary lymph node metastases in early breast cancer: systematic review and economic evaluation.

    Science.gov (United States)

    Cooper, K L; Meng, Y; Harnan, S; Ward, S E; Fitzgerald, P; Papaioannou, D; Wyld, L; Ingram, C; Wilkinson, I D; Lorenz, E

    2011-01-01

    Breast cancer is the most common type of cancer in women. Evaluation of axillary lymph node metastases is important for breast cancer staging and treatment planning. To evaluate the diagnostic accuracy, cost-effectiveness and effect on patient outcomes of positron emission tomography (PET), with or without computed tomography (CT), and magnetic resonance imaging (MRI) in the evaluation of axillary lymph node metastases in patients with newly diagnosed early-stage breast cancer. A systematic review of literature and an economic evaluation were carried out. Key databases (including MEDLINE, EMBASE and nine others) plus research registers and conference proceedings were searched for relevant studies up to April 2009. A decision-analytical model was developed to determine cost-effectiveness in the UK. One reviewer assessed titles and abstracts of studies identified by the search strategy, obtained the full text of relevant papers and screened them against inclusion criteria. Data from included studies were extracted by one reviewer using a standardised data extraction form and checked by a second reviewer. Discrepancies were resolved by discussion. Quality of included studies was assessed using the quality assessment of diagnostic accuracy studies (QUADAS) checklist, applied by one reviewer and checked by a second. Forty-five citations relating to 35 studies were included in the clinical effectiveness review: 26 studies of PET and nine studies of MRI. Two studies were included in the cost-effectiveness review: one of PET and one of MRI. Of the seven studies evaluating PET/CT (n = 862), the mean sensitivity was 56% [95% confidence interval (CI) 44% to 67%] and mean specificity 96% (95% CI 90% to 99%). Of the 19 studies evaluating PET only (n = 1729), the mean sensitivity was 66% (95% CI 50% to 79%) and mean specificity 93% (95% CI 89% to 96%). PET performed less well for small metastases; the mean sensitivity was 11% (95% CI 5% to 22%) for micrometastases (≤ 2 mm

  10. 18F-FDG PET in children with lymphomas

    International Nuclear Information System (INIS)

    Depas, Gisele; Barsy, Caroline De; Foidart, Jacqueline; Rigo, Pierre; Hustinx, Roland; Jerusalem, Guy; Hoyoux, Claire; Dresse, Marie-Francoise; Fassotte, Marie-France; Paquet, Nancy

    2005-01-01

    The aim of this study was to retrospectively evaluate the performance of positron emission tomography (PET) with 18 F-fluorodeoxyglucose ( 18 F-FDG) in children with lymphomas, at various stages of their disease. Twenty-eight children (mean age 12.5 years, 14 girls, 14 boys) with Hodgkin's disease (HD, n=17) or non-Hodgkin's lymphoma (NHL, n=11) were evaluated. Patients were investigated at initial staging (n=19), early in the course of treatment (n=19), at the end of treatment (n=16) and during long-term follow-up (n=19). A total of 113 whole-body PET studies were performed on dedicated scanners. PET results were compared with the results of conventional methods (CMs) such as physical examination, laboratory studies, chest X-rays, computed tomography, magnetic resonance imaging, ultrasonography and bone scan when available. At initial evaluation (group 1), PET changed the disease stage and treatment in 10.5% of the cases. In early evaluation of the response to treatment (group 2), PET failed to predict two relapses and one incomplete response to treatment. In this group, however, PET did not show any false positive results. There were only 4/75 false positive results for PET among patients studied at the end of treatment (group 3, specificity 94%) or during the systematic follow-up (group 4, specificity 95%), as compared with 27/75 for CMs (specificity 54% and 66%, respectively). 18 F-FDG-PET is a useful tool for evaluating children with lymphomas. Large prospective studies are needed to appreciate its real impact on patient management. (orig.)

  11. Fusion of PET and MRI for Hybrid Imaging

    Science.gov (United States)

    Cho, Zang-Hee; Son, Young-Don; Kim, Young-Bo; Yoo, Seung-Schik

    Recently, the development of the fusion PET-MRI system has been actively studied to meet the increasing demand for integrated molecular and anatomical imaging. MRI can provide detailed anatomical information on the brain, such as the locations of gray and white matter, blood vessels, axonal tracts with high resolution, while PET can measure molecular and genetic information, such as glucose metabolism, neurotransmitter-neuroreceptor binding and affinity, protein-protein interactions, and gene trafficking among biological tissues. State-of-the-art MRI systems, such as the 7.0 T whole-body MRI, now can visualize super-fine structures including neuronal bundles in the pons, fine blood vessels (such as lenticulostriate arteries) without invasive contrast agents, in vivo hippocampal substructures, and substantia nigra with excellent image contrast. High-resolution PET, known as High-Resolution Research Tomograph (HRRT), is a brain-dedicated system capable of imaging minute changes of chemicals, such as neurotransmitters and -receptors, with high spatial resolution and sensitivity. The synergistic power of the two, i.e., ultra high-resolution anatomical information offered by a 7.0 T MRI system combined with the high-sensitivity molecular information offered by HRRT-PET, will significantly elevate the level of our current understanding of the human brain, one of the most delicate, complex, and mysterious biological organs. This chapter introduces MRI, PET, and PET-MRI fusion system, and its algorithms are discussed in detail.

  12. PET/MRI. Methodology and clinical applications

    Energy Technology Data Exchange (ETDEWEB)

    Carrio, Ignasi [Autonomous Univ. of Barcelona, Hospital Sant Pau (Spain). Dept. Medicina Nuclear; Ros, Pablo (ed.) [Univ. Hospitals Case, Medical Center, Cleveland, OH (United States). Dept. of Radiology

    2014-04-01

    Provides detailed information on the methodology and equipment of MRI-PET. Covers a wide range of clinical applications in oncology, cardiology, and neurology. Written by an international group of experts in MRI and PET. PET/MRI is an exciting novel diagnostic imaging modality that combines the precise anatomic and physiologic information provided by magnetic resonance imaging (MRI) with the molecular data obtained with positron emission tomography (PET). PET/MRI offers the promise of a simplified work flow, reduced radiation, whole-body imaging with superior soft tissue contrast, and time of flight physiologic information. It has been described as the pathway to molecular imaging in medicine. In compiling this textbook, the editors have brought together a truly international group of experts in MRI and PET. The book is divided into two parts. The first part covers methodology and equipment and comprises chapters on basic molecular medicine, development of specific contrast agents, MR attenuation and validation, quantitative MRI and PET motion correction, and technical implications for both MRI and PET. The second part of the book focuses on clinical applications in oncology, cardiology, and neurology. Imaging of major neoplasms, including lymphomas and tumors of the breast, prostate, and head and neck, is covered in individual chapters. Further chapters address functional and metabolic cardiovascular examinations and major central nervous system applications such as brain tumors and dementias. Risks, safety aspects, and healthcare costs and impacts are also discussed. This book will be of interest to all radiologists and nuclear medicine physicians who wish to learn more about the latest developments in this important emerging imaging modality and its applications.

  13. Radiation monitoring of PET staff

    International Nuclear Information System (INIS)

    Trang, A.

    2004-01-01

    Full text: Positron emission tomography (PET) is becoming a common diagnostic tool in hospitals, often located in and employing staff from the Nuclear Medicine or Radiology departments. Although similar in some ways, staff in PET departments are commonly found to have the highest radiation doses in the hospital environment due to unique challenges which PET tracers present in administration as well as production. The establishment of a PET centre with a dedicated cyclotron has raised concerns of radiation protection to the staff at the WA PET Centre and the Radiopharmaceutical Production and Development (RAPID) team. Since every PET centre has differing designs and practices, it was considered important to closely monitor the radiation dose to our staff so that improvements to practices and design could be made to reduce radiation dose. Electronic dosimeters (MGP DMC 2000XB), which have a facility to log time and dose at 10 second intervals, were provided to three PET technologists and three PET nurses. These were worn in the top pocket of their lab coats throughout a whole day. Each staff member was then asked to note down their duties throughout the day and also note the time they performed each duty. The duties would then correlate with the dose with which the electronic monitor recorded and an estimate of radiation dose per duty could be given. Also an estimate of the dose per day to each staff member could be made. PET nurses averaged approximately 20 μ8v per day getting their largest dose from caring for occasional problematic patients. Smaller doses of a 1-2 μ8v were recorded for injections and removing cannulas. PET technologists averaged approximately 15 μ8v per day getting their largest dose of 1-5μ8v mainly from positioning of patients and sometimes larger doses due to problematic patients. Smaller doses of 1-2 μ5v were again recorded for injections and removal of cannulas. Following a presentation given to staff, all WA PET Centre and RAPID staff

  14. Hybrid PET/MRI insert: B0 field optimization by applying active and passive shimming on PET detector level

    Energy Technology Data Exchange (ETDEWEB)

    Wehner, Jakob [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Weissler, Bjoern [Philips Research Europe, Aachen (Germany); Schulz, Volkmar [Department of Physics of Molecular Imaging Systems, Institute for Experimental Molecular Imaging, RWTH Aachen University, Aachen (Germany); Philips Research Europe, Aachen (Germany)

    2014-07-29

    Combining PET and MRI into a hybrid device is challenging since both systems might influence each other. A typical interference problem of such a combined device is the distortion of the MRI’s B{sub 0} field distribution due to the material brought inside the MRI’s FOV which is in particular challenging for small-bore PET-systems. High field homogeneity is needed for a good MRI acquisition in general as well as in certain applications. Typically, active shimming using dedicated coils is applied to improve the field homogeneity. However, these techniques are limited especially for localized distortion profiles with higher-order characteristics caused by PET/MRI inserts. As a consequence, we are exploring the potential application of shimming on PET detector level (for the Hyperion-II{sup D} PET/MRI insert), meaning that the distortion profile caused by PET modules is compensated using additional magnetic materials (passive shimming) and DC coils (active shimming). To explore the technique, B{sub 0} field measurements have been performed using a whole-body phantom in combination with the MRI body coil. An FFE sequence was used to measure distortion maps of DC loops and small magnetic objects (capacitors, ferrites). These distortion maps served as input for a software framework which has been written to perform the field optimization. The implementation was verified by measurements and fits were performed to extract characteristic parameters of the tested objects. Finally, the implemented software framework was used to homogenize a measured distortion map produced by a single PET module by superimposing distortion corrections from additional simulated materials. The resulting superimposed distortion map showed a significantly improved B{sub 0} field map quality (reduced spectral width and improved homogeneity). The simulated susceptibility distribution will be applied on PET module level and tested in experiments. Results and details about this study will be

  15. Intramedullary Spinal Cord Metastasis from Breast Cancer Mimicking Delayed Radiation Myelopathy: Detection With {sup 18}F-FDG PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Kawamoto, Terufumi; Yamashita, Toshinari; Katio, Satoshi; Miura, Yoshiharu [Komagome Hospital, Tokyo (Japan)

    2016-06-15

    We present the case of a 53-year-old woman with breast cancer who developed vertebral body metastases at the 7-10th thoracic vertebrae (Th7-10) and started radiotherapy in April 2011. Radio therapy was administered in 15 fractions of 2.5 Gy each to the vertebral bodies. Total dose to the tumor was 37.5 Gy. The result of such studies showed that most of the SUV Values in malignant lesions were increased in the delayed can and for most benign lesions these delayed values decreased. In '1{sup 8}F-FDG PET/ CT has an important role to play in the diagnosis of ISCM and the differentiation from DRM.

  16. Tumour 18 F-FDG Uptake on preoperative PET/CT may predict axillary lymph node metastasis in ER-positive/HER2-negative and HER2-positive breast cancer subtypes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin You; Lee, Suck Hong; Kim, Suk [Pusan National University Hospital, Pusan National University School of Medicine and Medical Research Institute, Department of Radiology, Seo-gu, Busan (Korea, Republic of); Kang, Taewoo [Pusan National University Hospital, Busan Cancer Center, Busan (Korea, Republic of); Bae, Young Tae [Pusan National University Hospital, Department of Surgery, Busan (Korea, Republic of)

    2015-04-01

    To evaluate the association between tumour FDG uptake on preoperative PET/CT and axillary lymph node metastasis (ALNM) according to breast cancer subtype. The records of 671 patients with invasive breast cancer who underwent {sup 18} F-FDG PET/CT and surgery were reviewed. Using immunohistochemistry, tumours were divided into three subtypes: oestrogen receptor (ER)-positive/human epidermal growth factor receptor 2 (HER2)-negative, HER2-positive, and triple-negative. Tumour FDG uptake, expressed as maximum standardized uptake value (SUV{sub max}), and clinicopathological variables were analysed. ALNM was present in 187 of 461 ER-positive/HER2-negative, 54 of 97 HER2-positive, and 38 of 113 triple-negative tumours. On multivariate analysis, high tumour SUV{sub max} (≥4.25) (P < 0.001), large tumour size (>2 cm) (P = 0.003) and presence of lymphovascular invasion (P < 0.001) were independent variables associated with ALNM. On subset analyses, tumour SUV{sub max} maintained independent significance for predicting ALNM in ER-positive/HER2-negative (adjusted odds ratio: 3.277, P < 0.001) and HER2-positive tumours (adjusted odds ratio: 14.637, P = 0.004). No association was found for triple-negative tumours (P = 0.161). Tumour SUV{sub max} may be an independent prognostic factor for ALNM in patients with invasive breast cancer, especially in ER-positive/HER2-negative and HER2-positive subtypes, but not in those with triple-negative subtype. (orig.)

  17. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    International Nuclear Information System (INIS)

    Hope, Thomas A.; Verdin, Emily F.; Bergsland, Emily K.; Ohliger, Michael A.; Corvera, Carlos University; Nakakura, Eric K.

    2015-01-01

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV max , SUV peak , SUV mean , and Vol isocontour . Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV max 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV max 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  18. Correcting for respiratory motion in liver PET/MRI: preliminary evaluation of the utility of bellows and navigated hepatobiliary phase imaging

    Energy Technology Data Exchange (ETDEWEB)

    Hope, Thomas A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco VA Medical Center, San Francisco, CA (United States); Verdin, Emily F. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Bergsland, Emily K. [Division of Hematology/Oncology, Department of Medicine, University of California, San Francisco, San Francisco, CA (United States); Ohliger, Michael A. [Department of Radiology and Biomedical Imaging, University of California, San Francisco, San Francisco, CA (United States); Department of Radiology, San Francisco General Hospital, San Francisco, CA (United States); Corvera, Carlos University; Nakakura, Eric K. [Division of Surgical Oncology, Department of Surgery, University of California, San Francisco, San Francisco, CA (United States)

    2015-09-18

    The purpose of this study was to evaluate the utility of bellows-based respiratory compensation and navigated hepatobiliary phase imaging to correct for respiratory motion in the setting of dedicated liver PET/MRI. Institutional review board approval and informed consent were obtained. Six patients with metastatic neuroendocrine tumor were imaged using Ga-68 DOTA-TOC PET/MRI. Whole body imaging and a dedicated 15-min liver PET acquisition was performed, in addition to navigated and breath-held hepatobiliary phase (HBP) MRI. Liver PET data was reconstructed three ways: the entire data set (liver PET), gated using respiratory bellows (RC-liver PET), and a non-gated data set reconstructed using the same amount of data used in the RC-liver PET (shortened liver PET). Liver lesions were evaluated using SUV{sub max}, SUV{sub peak}, SUV{sub mean}, and Vol{sub isocontour}. Additionally, the displacement of each lesion between the RC-liver PET images and the navigated and breath-held HBP images was calculated. Respiratory compensation resulted in a 43 % increase in SUVs compared to ungated data (liver vs RC-liver PET SUV{sub max} 26.0 vs 37.3, p < 0.001) and a 25 % increase compared to a non-gated reconstruction using the same amount of data (RC-liver vs shortened liver PET SUV{sub max} 26.0 vs 32.6, p < 0.001). Lesion displacement was minimized using navigated HBP MRI (1.3 ± 1.0 mm) compared to breath-held HBP MRI (23.3 ± 1.0 mm). Respiratory bellows can provide accurate respiratory compensation when imaging liver lesions using PET/MRI, and results in increased SUVs due to a combination of increased image noise and reduced respiratory blurring. Additionally, navigated HBP MRI accurately aligns with respiratory compensated PET data.

  19. [{sup 18}F]FDG PET/CT features for the molecular characterization of primary breast tumors

    Energy Technology Data Exchange (ETDEWEB)

    Antunovic, Lidija [Humanitas Research Hospital, Nuclear Medicine Department, Milan (Italy); Gallivanone, Francesca; Castiglioni, Isabella [National Research Council, Laboratory of Innovation and Integration in Molecular Medicine, Institute of Molecular Bioimaging and Physiology, Milan (Italy); Sollini, Martina; Kirienko, Margarita [Humanitas University, Department of Biomedical Sciences, Milan (Italy); Sagona, Andrea; Tinterri, Corrado [Humanitas Research Hospital, Breast Unit, Milan (Italy); Invento, Alessandra [Integrated University Hospital, Breast Unit, Verona (Italy); Manfrinato, Giulia [University of Milan, Residency Program in Nuclear Medicine, Milan (Italy); Chiti, Arturo [Humanitas Research Hospital, Nuclear Medicine Department, Milan (Italy); Humanitas University, Department of Biomedical Sciences, Milan (Italy)

    2017-11-15

    The aim of this study was to evaluate the role of imaging features derived from [{sup 18}F]FDG-PET/CT to provide in vivo characterization of breast cancer (BC). Images from 43 patients with a first diagnosis of BC were reviewed. Images were acquired before any treatment. Histological data were derived from pretreatment biopsy or surgical histological specimen; these included tumor type, grade, ER and PgR receptor status, lymphovascular invasion, Ki67 index, HER2 status, and molecular subtype. Standard parameters (SUV{sub mean}, TLG, MTV) and advanced imaging features (histogram-based and shape and size features) were evaluated. Univariate analysis, hierarchical clustering analysis, and exact Fisher's test were used for statistical analysis of data. Imaging-derived metrics were reduced evaluating the mutual correlation within group of features as well as the mutual correlation between groups of features to form a signature. A significant correlation was found between some advanced imaging features and the histological type. Different molecular subtypes were characterized by different values of two histogram-based features (median and energy). A significant association was observed between the imaging signature and luminal A and luminal B HER2 negative molecular subtype and also when considering luminal A, luminal B HER2-negative and HER2-positive groups. Similar results were found between the signature and all five molecular subtypes and also when considering the histological types of BC. Our results suggest a complementary role of standard PET imaging parameters and advanced imaging features for the in vivo biological characterization of BC lesions. (orig.)

  20. Design of a coincidence processing board for a dual-head PET scanner for breast imaging

    International Nuclear Information System (INIS)

    Martinez, J.D.; Toledo, J.; Esteve, R.; Sebastia, A.; Mora, F.J.; Benlloch, J.M.; Fernandez, M.M.; Gimenez, M.; Gimenez, E.N.; Lerche, Ch.W.; Pavon, N.; Sanchez, F.

    2005-01-01

    This paper describes the design of a coincidence processing board for a dual-head Positron Emission Tomography (PET) scanner for breast imaging. The proposed block-oriented data acquisition system relies on a high-speed DSP processor for fully digital trigger and on-line event processing that surpasses the performance of traditional analog coincidence detection systems. A mixed-signal board has been designed and manufactured. The analog section comprises 12 coaxial inputs (six per head) which are digitized by means of two 8-channel 12-bit 40-MHz ADCs in order to acquire the scintillation pulse, the charge division signals and the depth of interaction within the scintillator. At the digital section, a state-of-the-art FPGA is used as deserializer and also implements the DMA interface to the DSP processor by storing each digitized channel into a fast embedded FIFO memory. The system incorporates a high-speed USB 2.0 interface to the host computer

  1. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    Energy Technology Data Exchange (ETDEWEB)

    Efthimiou, Nikos [Technological Educational Institute of Athens (Greece); Kostou, Theodora; Papadimitroulas, Panagiotis [Technological Educational Institute of Athens (Greece); Department of Medical Physics, School of Medicine, University of Patras (Greece); Charalampos, Tsoumpas [Division of Biomedical Imaging, University of Leeds, Leeds (United Kingdom); Loudos, George [Technological Educational Institute of Athens (Greece)

    2015-05-18

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  2. Initial reconstruction results from a simulated adaptive small animal C shaped PET/MR insert

    International Nuclear Information System (INIS)

    Efthimiou, Nikos; Kostou, Theodora; Papadimitroulas, Panagiotis; Charalampos, Tsoumpas; Loudos, George

    2015-01-01

    Traditionally, most clinical and preclinical PET scanners, rely on full cylindrical geometry for whole body as well as dedicated organ scans, which is not optimized with regards to sensitivity and resolution. Several groups proposed the construction of dedicated PET inserts for MR scanners, rather than the construction of new integrated PET/MR scanners. The space inside an MR scanner is a limiting factor which can be reduced further with the use of extra coils, and render the use of non-flexible cylindrical PET scanners difficult if not impossible. The incorporation of small SiPM arrays, can provide the means to design adaptive PET scanners to fit in tight locations, which, makes imaging possible and improve the sensitivity, due to the closer approximation to the organ of interest. In order to assess the performance of such a device we simulated the geometry of a C shaped PET, using GATE. The design of the C-PET was based on a realistic SiPM-BGO scenario. In order reconstruct the simulated data, with STIR, we had to calculate system probability matrix which corresponds to this non standard geometry. For this purpose we developed an efficient multi threaded ray tracing technique to calculate the line integral paths in voxel arrays. One of the major features is the ability to automatically adjust the size of FOV according to the geometry of the detectors. The initial results showed that the sensitivity improved as the angle between the detector arrays increases, thus better angular sampling the scanner's field of view (FOV). The more complete angular coverage helped in improving the shape of the source in the reconstructed images, as well. Furthermore, by adapting the FOV to the closer to the size of the source, the sensitivity per voxel is improved.

  3. [{sup 18}F]FDG PET/MRI vs. PET/CT for whole-body staging in patients with recurrent malignancies of the female pelvis: initial results

    Energy Technology Data Exchange (ETDEWEB)

    Beiderwellen, Karsten; Grueneisen, Johannes; Forsting, Michael; Lauenstein, Thomas C.; Umutlu, Lale [University Hospital Essen, University of Duisburg-Essen, Department of Diagnostic and Interventional Radiology and Neuroradiology, Essen (Germany); Ruhlmann, Verena [University Hospital Essen, University of Duisburg-Essen, Clinic for Nuclear Medicine, Essen (Germany); Buderath, Paul; Aktas, Bahriye [University Hospital Essen, University of Duisburg-Essen, Clinic for Obstetrics and Gynecology, Essen (Germany); Heusch, Philipp [University of Dusseldorf, Department of Diagnostic and Interventional Radiology, Dusseldorf (Germany); Kraff, Oliver [University of Duisburg-Essen, Erwin L. Hahn Institute for Magnetic Resonance Imaging, Essen (Germany)

    2015-01-15

    To evaluate the diagnostic potential of PET/MRI with [{sup 18}F]FDG in recurrent ovarian and cervical cancer in comparison to PET/CT. A group of 19 patients with suspected recurrence of pelvic malignancies (ovarian cancer, 11 patients; cervical cancer, 8 patients) scheduled for an [{sup 18}F]FDG PET/CT were subsequently enrolled for a PET/MRI. The scan protocol comprised: (1) a T1-W axial VIBE after contrast agent adminstration, (2) an axial T2-W HASTE, (3) a coronal TIRM, (4) an axial DWI, and dedicated MR sequences of the female pelvis including (5) a T1-W VIBE before contrast agent adminstration, (6) a sagittal T2-W TSE, and (7) a sagittal T1-W dynamic VIBE. The datasets (PET/CT, PET/MRI) were rated separately by two readers regarding lesion count, lesion localization, lesion conspicuity (four-point scale), lesion characterization (benign/malignant/indeterminate) and diagnostic confidence (three-point scale). All available data (histology, prior examinations, PET/CT, PET/MRI, follow-up examinations) served as standard of reference. Median values were compared using the Wilcoxon rank sum test. Metastatic lesions were present in 16 of the 19 patients. A total of 78 lesions (malignant, 58; benign, 20) were described. Both PET/CT and PET/MRI allowed correct identification of all malignant lesions and provided equivalent conspicuity (3.86 ± 0.35 for PET/CT, 3.91 ± 0.28 for PET/MRI; p > 0.05). Diagnostic confidence was significantly higher for PET/MRI in malignant (p < 0.01) and benign lesions (p < 0.05). Both PET/CT and PET/MRI offer an equivalently high diagnostic value for recurrent pelvic malignancies. PET/MRI offers higher diagnostic confidence in the discrimination of benign and malignant lesions. Considering the reduced radiation dose and superior lesion discrimination, PET/MRI may serve as a powerful alternative to PET/CT in the future. (orig.)

  4. Tryptophan metabolism in breast cancers: molecular imaging and immunohistochemistry studies

    International Nuclear Information System (INIS)

    Juhász, Csaba; Nahleh, Zeina; Zitron, Ian; Chugani, Diane C.; Janabi, Majid Z.; Bandyopadhyay, Sudeshna; Ali-Fehmi, Rouba; Mangner, Thomas J.; Chakraborty, Pulak K.; Mittal, Sandeep; Muzik, Otto

    2012-01-01

    Introduction: Tryptophan oxidation via the kynurenine pathway is an important mechanism of tumoral immunoresistance. Increased tryptophan metabolism via the serotonin pathway has been linked to malignant progression in breast cancer. In this study, we combined quantitative positron emission tomography (PET) with tumor immunohistochemistry to analyze tryptophan transport and metabolism in breast cancer. Methods: Dynamic α-[ 11 C]methyl-L-tryptophan (AMT) PET was performed in nine women with stage II–IV breast cancer. PET tracer kinetic modeling was performed in all tumors. Expression of L-type amino acid transporter 1 (LAT1), indoleamine 2,3-dioxygenase (IDO; the initial and rate-limiting enzyme of the kynurenine pathway) and tryptophan hydroxylase 1 (TPH1; the initial enzyme of the serotonin pathway) was assessed by immunostaining of resected tumor specimens. Results: Tumor AMT uptake peaked at 5–20 min postinjection in seven tumors; the other two cases showed protracted tracer accumulation. Tumor standardized uptake values (SUVs) varied widely (2.6–9.8) and showed a strong positive correlation with volume of distribution values derived from kinetic analysis (P < .01). Invasive ductal carcinomas (n = 6) showed particularly high AMT SUVs (range, 4.7–9.8). Moderate to strong immunostaining for LAT1, IDO and TPH1 was detected in most tumor cells. Conclusions: Breast cancers show differential tryptophan kinetics on dynamic PET. SUVs measured 5–20 min postinjection reflect reasonably the tracer's volume of distribution. Further studies are warranted to determine if in vivo AMT accumulation in these tumors is related to tryptophan metabolism via the kynurenine and serotonin pathways.

  5. Initial clinical results of simultaneous {sup 18}F-FDG PET/MRI in comparison to {sup 18}F-FDG PET/CT in patients with head and neck cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kubiessa, K.; Gawlitza, M.; Kuehn, A.; Fuchs, J.; Kahn, T.; Stumpp, P. [University Hospital of Leipzig, Department of Diagnostic and Interventional Radiology, Leipzig (Germany); Purz, S.; Steinhoff, K.G.; Sabri, O.; Kluge, R. [University Hospital of Leipzig, Department of Nuclear Medicine, Leipzig (Germany); Boehm, A. [University Hospital of Leipzig, ENT Department, Leipzig (Germany)

    2014-04-15

    The aim of this study was to evaluate the diagnostic capability of simultaneous {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography (PET)/MRI compared to {sup 18}F-FDG PET/CT as well as their single components in head and neck cancer patients. In a prospective study 17 patients underwent {sup 18}F-FDG PET/CT for staging or follow-up and an additional {sup 18}F-FDG PET/MRI scan with whole-body imaging and dedicated examination of the neck. MRI, CT and PET images as well as PET/MRI and PET/CT examinations were evaluated independently and in a blinded fashion by two reader groups. Results were compared with the reference standard (final diagnosis determined in consensus using all available data including histology and follow-up). Sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were calculated. A total of 23 malignant tumours were found with the reference standard. PET/CT showed a sensitivity of 82.7 %, a specificity of 87.3 %, a PPV of 73.2 % and a NPV of 92.4 %. Corresponding values for PET/MRI were 80.5, 88.2, 75.6 and 92.5 %. No statistically significant difference in diagnostic capability could be found between PET/CT and PET/MRI. Evaluation of the PET part from PET/CT revealed highest sensitivity of 95.7 %, and MRI showed best specificity of 96.4 %. There was a high inter-rater agreement in all modalities (Cohen's kappa 0.61-0.82). PET/MRI of patients with head and neck cancer yielded good diagnostic capability, similar to PET/CT. Further studies on larger cohorts to prove these first results seem justified. (orig.)

  6. Clinical Significance of 18F-FDG-PET in Invasive Lobular Carcinoma.

    Science.gov (United States)

    Fujii, Takaaki; Yajima, Reina; Kurozumi, Sasagu; Higuchi, Toru; Obayashi, Sayaka; Tokiniwa, Hideaki; Nagaoka, Rin; Takata, Daisuke; Horiguchi, Jun; Kuwano, Hiroyuki

    2016-10-01

    The diagnostic utility of 18 F-fluorodeoxyglucose (FDG)-positron emission tomography (PET) for breast cancer is controversial. The histological type or tumor size of breast cancer has been reported to be associated with a greater likelihood of positive FDG uptake. Compared to invasive ductal carcinomas (IDCs), invasive lobular carcinomas (ILCs) have a lower level of FDG uptake and are detected at a significantly lower sensitivity. The role of preoperative FDG-PET for ILCs may, thus, be limited. Few data evaluating the significance of FDG-PET in ILCs are available. Here, we evaluated the clinical significance of FDG-PET for ILC patients. We retrospectively investigated the cases of 196 consecutive patients with primary breast cancer who were diagnosed as having ILC (n=15) or IDC (n=181) and underwent FDG-PET preoperatively. Fifteen (7.7%) of patients were histopathologically diagnosed as ILC. A univariate analysis revealed that tumor size, extent of tumor, estrogen receptor (ER) expression and progesterone receptor (PgR) expression were significantly different between the ILC and IDC groups. The maximum standardized uptake value (SUV max ) values of the primary tumors were not significantly different between the two groups but, regardless of the larger size of tumor or ductal spread, the SUV max was relatively lower in the ILC group compared to the IDC group. The tumors in two ILC cases showed no FDG uptake. Among the ILC cases, there were linear associations between SUV max and tumor size and between SUV max and the nuclear grade by Pearson correlation (r=0.447, p=0.048 and r=0.519, p=0.024, respectively). Our findings imply that the preoperative FDG uptake in ILC may be reflective of the tumor size and the nuclear grade of the tumor. FDG uptake may be useful and predictive of aggressive features or prognosis in ILC patients. Copyright© 2016 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  7. Poster - 01: LabPET II Pixelated APD-Based PET Scanner for High-Resolution Preclinical Imaging

    Energy Technology Data Exchange (ETDEWEB)

    Lecomte, Roger; Arpin, Louis; Beaudoin, Jean-François; Bergeron, Mélanie; Bouchard, Jonathan; Bouziri, Haithem; Cadorette, Jules; Gaudin, Émilie; Jürgensen, Nadia; Koua, Konin Calliste; Trépanier, Pierre-Yves Lauzier; Leroux, Jean-Daniel; Loignon-Houle, Francis; Njejimana, Larissa; Paillé, Maxime; Paulin, Caroline; Pepin, Catherine; Pratte, Jean-François; Samson, Arnaud; Thibaudeau, Christian [Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke, Novalgo Inc., Université de Sherbrooke, Université de Sherbrooke, CIMS/CRCHUS, 3IT, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, Université de Sherbrooke, 3IT, Université de Sherbrooke (Canada); and others

    2016-08-15

    Purpose: LabPET II is a new generation APD-based PET scanner designed to achieve sub-mm spatial resolution using truly pixelated detectors and highly integrated parallel front-end processing electronics. Methods: The basic element uses a 4×8 array of 1.12×1.12 mm{sup 2} Lu{sub 1.9}Y{sub 0.1}SiO{sub 5}:Ce (LYSO) scintillator pixels with one-to-one coupling to a 4×8 pixelated monolithic APD array mounted on a ceramic carrier. Four detector arrays are mounted on a daughter board carrying two flip-chip, 64-channel, mixed-signal, application-specific integrated circuits (ASIC) on the backside interfacing to two detector arrays each. Fully parallel signal processing was implemented in silico by encoding time and energy information using a dual-threshold Time-over-Threshold (ToT) scheme. The self-contained 128-channel detector module was designed as a generic component for ultra-high resolution PET imaging of small to medium-size animals. Results: Energy and timing performance were optimized by carefully setting ToT thresholds to minimize the noise/slope ratio. ToT spectra clearly show resolved 511 keV photopeak and Compton edge with ToT resolution well below 10%. After correction for nonlinear ToT response, energy resolution is typically 24±2% FWHM. Coincidence time resolution between opposing 128-channel modules is below 4 ns FWHM. Initial imaging results demonstrate that 0.8 mm hot spots of a Derenzo phantom can be resolved. Conclusion: A new generation PET scanner featuring truly pixelated detectors was developed and shown to achieve a spatial resolution approaching the physical limit of PET. Future plans are to integrate a small-bore dedicated mouse version of the scanner within a PET/CT platform.

  8. Evaluation of lymph node status after neoadjuvant chemotherapy in breast cancer patients: comparison of diagnostic performance of ultrasound, MRI and ¹⁸F-FDG PET/CT.

    Science.gov (United States)

    You, S; Kang, D K; Jung, Y S; An, Y-S; Jeon, G S; Kim, T H

    2015-08-01

    To evaluate the diagnostic performance of ultrasound, MRI and fluorine-18 fludeoxyglucose positron emission tomography (¹⁸F-FDG PET)/CT for the diagnosis of metastatic axillary lymph node (ALN) after neoadjuvant chemotherapy (NAC) and to find out histopathological factors affecting the diagnostic performance of these imaging modalities. From January 2012 to November 2014, 191 consecutive patients with breast cancer who underwent NAC before surgery were retrospectively reviewed. We included 139 patients with ALN metastasis that was confirmed on fine needle aspiration or core needle biopsy at initial diagnosis. After NAC, 39 (28%) patients showed negative conversion of ALN on surgical specimens of sentinel lymph node (LN) or ALN. The sensitivity of ultrasound, MRI and PET/CT was 50% (48/96), 72% (70/97) and 22% (16/73), respectively. The specificity of ultrasound, MRI and PET/CT was 77% (30/39), 54% (21/39) and 85% (22/26), respectively. The Az value of combination of ultrasound and PET/CT was the highest (0.634) followed by ultrasound (0.626) and combination of ultrasound, MRI and PET/CT (0.617). The size of tumour deposit in LN and oestrogen receptor was significantly associated with the diagnostic performance of ultrasound (p performance of PET/CT (p = 0.023, p = 0.002, p = 0.036, p = 0.044 and p = 0.008, respectively). On multivariate logistic regression analysis, size of tumour deposit within LN was identified as being independently associated with diagnostic performance of ultrasound [odds ratio, 13.07; 95% confidence interval (CI), 2.95-57.96] and PET/CT (odds ratio, 6.47; 95% CI, 1.407-29.737). Combination of three imaging modalities showed the highest sensitivity, and PET/CT showed the highest specificity for the evaluation of ALN metastasis after NAC. Ultrasound alone or combination of ultrasound and PET/CT showed the highest positive-predictive value. The size of tumour deposit within ALN was significantly associated with

  9. Current applications of PET imaging of sex hormone receptors with a fluorinated analogue of estradiol or of testosterone

    International Nuclear Information System (INIS)

    Talbot, J-N.; Montravers, F.; Huchet, V.; Michaud, L.; Ohnona, J.; Balogova, S.; Kerrou, K.; Gligorov, V.; Lotz, P.; Nataf, V.; Cussenot, O.; Darai, E.

    2015-01-01

    Currently, the most frequent approach in the oncologic applications of positron emission tomography (PET) is detecting the hypermetabolic activity of the cancer tissue. A more specific approach, which may be complementary, is detecting the overexpression of receptors. In this review article, we aim to evaluate the results that are currently available for PET imaging of the sex hormone receptors in clinical oncology. The indication of PET and now PET/CT has been more disputed in breast carcinoma than in many other primary cancers (e.g., lung, head and neck, colorectal, lymphoma). 18 F-fluorodeoxyglucose (FDG), the glucose analogue for PET imaging, has a limited sensitivity to detect the primary breast tumors in case of lobular or in situ forms or small sized tumors localised on systematic mammography, and to identify minimal node invasion in the axilla. Using 16α-( 18 F]fluoro-17β-estradiol (FES), a fluorinated estradiol analogue, PET is able to detect the over-expression of the oestrogen receptor (ER) in lesions, at a whole-body level. FES and FDG appear complementary for a better diagnostic performance in staging locally advanced breast cancer or restaging recurrent or metastatic breast cancer. Another potential indication is predicting the response to starting or resuming hormone therapy in patients with metastatic breast cancer, in relation with the ER status of all lesions revealed by FES PET. In two retrospective studies, FDG PET was also able to predict the response to hormone therapy, on basis of a metabolic flare, observed either after 7-10 days of treatment or during an estradiol challenge. A prospective comparison of those approaches is warranted. One study reported predicting response to neoadjuvant chemotherapy thanks to a low value of FES SUV m ax or FES/FDG SUV max ratio. The presence of ER in uterine tumors, including the benign ones, in ovarian cancers or even in meningiomas, may have therapeutic consequences and FES PET could have a clinical

  10. Positron Emission Tomography (PET in Oncology

    Directory of Open Access Journals (Sweden)

    Andrea Gallamini

    2014-09-01

    Full Text Available Since its introduction in the early nineties as a promising functional imaging technique in the management of neoplastic disorders, FDG-PET, and subsequently FDG-PET/CT, has become a cornerstone in several oncologic procedures such as tumor staging and restaging, treatment efficacy assessment during or after treatment end and radiotherapy planning. Moreover, the continuous technological progress of image generation and the introduction of sophisticated software to use PET scan as a biomarker paved the way to calculate new prognostic markers such as the metabolic tumor volume (MTV and the total amount of tumor glycolysis (TLG. FDG-PET/CT proved more sensitive than contrast-enhanced CT scan in staging of several type of lymphoma or in detecting widespread tumor dissemination in several solid cancers, such as breast, lung, colon, ovary and head and neck carcinoma. As a consequence the stage of patients was upgraded, with a change of treatment in 10%–15% of them. One of the most evident advantages of FDG-PET was its ability to detect, very early during treatment, significant changes in glucose metabolism or even complete shutoff of the neoplastic cell metabolism as a surrogate of tumor chemosensitivity assessment. This could enable clinicians to detect much earlier the effectiveness of a given antineoplastic treatment, as compared to the traditional radiological detection of tumor shrinkage, which usually takes time and occurs much later.

  11. Positron Emission Tomography (PET) in Oncology

    Energy Technology Data Exchange (ETDEWEB)

    Gallamini, Andrea, E-mail: gallamini.a@ospedale.cuneo.it [Department of Research and Medical Innovation, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Zwarthoed, Colette [Department of Nuclear Medicine, Antoine Lacassagne Cancer Center, Nice University, Nice Cedex 2-06189 Nice (France); Borra, Anna [Hematology Department S. Croce Hospital, Via M. Coppino 26, Cuneo 12100 (Italy)

    2014-09-29

    Since its introduction in the early nineties as a promising functional imaging technique in the management of neoplastic disorders, FDG-PET, and subsequently FDG-PET/CT, has become a cornerstone in several oncologic procedures such as tumor staging and restaging, treatment efficacy assessment during or after treatment end and radiotherapy planning. Moreover, the continuous technological progress of image generation and the introduction of sophisticated software to use PET scan as a biomarker paved the way to calculate new prognostic markers such as the metabolic tumor volume (MTV) and the total amount of tumor glycolysis (TLG). FDG-PET/CT proved more sensitive than contrast-enhanced CT scan in staging of several type of lymphoma or in detecting widespread tumor dissemination in several solid cancers, such as breast, lung, colon, ovary and head and neck carcinoma. As a consequence the stage of patients was upgraded, with a change of treatment in 10%–15% of them. One of the most evident advantages of FDG-PET was its ability to detect, very early during treatment, significant changes in glucose metabolism or even complete shutoff of the neoplastic cell metabolism as a surrogate of tumor chemosensitivity assessment. This could enable clinicians to detect much earlier the effectiveness of a given antineoplastic treatment, as compared to the traditional radiological detection of tumor shrinkage, which usually takes time and occurs much later.

  12. Pretreatment Staging Positron Emission Tomography/Computed Tomography in Patients With Inflammatory Breast Cancer Influences Radiation Treatment Field Designs

    International Nuclear Information System (INIS)

    Walker, Gary V.; Niikura, Naoki; Yang Wei; Rohren, Eric; Valero, Vicente; Woodward, Wendy A.; Alvarez, Ricardo H.; Lucci, Anthony; Ueno, Naoto T.; Buchholz, Thomas A.

    2012-01-01

    Purpose: Positron emission tomography/computed tomography (PET/CT) is increasingly being utilized for staging of inflammatory breast cancer (IBC). The purpose of this study was to define how pretreatment PET/CT studies affected postmastectomy radiation treatment (PMRT) planning decisions for IBC. Methods and Materials: We performed a retrospective analysis of 62 patients diagnosed with IBC between 2004 and 2009, who were treated with PMRT in our institution and who had a staging PET/CT within 3 months of diagnosis. Patients received a baseline physical examination, staging mammography, ultrasonographic examination of breast and draining lymphatics, and chest radiography; most patients also had a bone scan (55 patients), liver imaging (52 patients), breast MRI (46 patients), and chest CT (25 patients). We compared how PET/CT findings affected PMRT, assuming that standard PMRT would target the chest wall, level III axilla, supraclavicular fossa, and internal mammary chain (IMC). Any modification of target volumes, field borders, or dose prescriptions was considered a change. Results: PET/CT detected new areas of disease in 27 of the 62 patients (44%). The areas of additional disease included the breast (1 patient), ipsilateral axilla (1 patient), ipsilateral supraclavicular (4 patients), ipsilateral infraclavicular (1 patient), ipsilateral IMC (5 patients), ipsilateral subpectoral (3 patients), mediastinal (8 patients), other distant/contralateral lymph nodes (15 patients), or bone (6 patients). One patient was found to have a non-breast second primary tumor. The findings of the PET/CT led to changes in PMRT in 11 of 62 patients (17.7%). These changes included additional fields in 5 patients, adjustment of fields in 2 patients, and higher doses to the supraclavicular fossa (2 patients) and IMC (5 patients). Conclusions: For patients with newly diagnosed IBC, pretreatment PET/CT provides important information concerning involvement of locoregional lymph nodes

  13. Spatial resolution of the HRRT PET scanner using 3D-OSEM PSF reconstruction

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter; Sibomana, Merence; Keller, Sune Høgild

    2009-01-01

    The spatial resolution of the Siemens High Resolution Research Tomograph (HRRT) dedicated brain PET scanner installed at Copenhagen University Hospital (Rigshospitalet) was measured using a point-source phantom with high statistics. Further, it was demonstrated how the newly developed 3D-OSEM PSF...

  14. Clinical utility of scintimammography: From the Anger-camera to new dedicated devices

    Energy Technology Data Exchange (ETDEWEB)

    Schillaci, Orazio [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)]. E-mail: oschil@tiscali.it; Danieli, Roberta [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Romano, Pasquale [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Cossu, Elsa [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy); Simonetti, Giovanni [Department of Biopathology and Diagnostic Imaging, University ' Tor Vergata' , Viale G. Mazzini 121, 00195 Rome (Italy)

    2006-12-20

    Scintimammography is a functional imaging technique which uses a radiation detection camera to detect radionuclide tracers in the patient's breasts. Tracers are designed to accumulate in tumours more than in healthy tissue: the most used are Tc-99 m sestamibi and Tc-99 m tetrofosmin. Scintimammography is useful in some clinical indications as an adjunct to mammography: it is recommended for those lesions where additional information is required to reach a definitive diagnosis. Patients with dubious mammograms may benefit from this test, as well as women with dense breasts or with implants. Scintimammography is a valuable diagnostic tool also in patients with locally advanced breast cancer for monitoring and predicting response to neoadjuvant chemotherapy. Nevertheless, using an Anger-camera this technique shows a high sensitivity only for cancers >1 cm. Since other modalities are increasingly employed for the early identification of small abnormalities, the issue of detecting small cancers is critical for the future development and clinical utility of breast imaging with radiopharmaceuticals. The use of high-resolution cameras dedicated for breast imaging is the best option to improve the detection of small cancers: they allow higher flexibility in patient positioning, and the availability of mammography-like projections. Moreover, the detector can be placed directly in contact with the breast allowing a mild compression with reduction of the breast's thickness, thus increasing the target-to-background ratio and the sensitivity. These new devices have the potential of increasing the total number of breast scintigraphies performed thereby enhancing the role of nuclear medicine in breast cancer imaging.

  15. Towards Implementing an MR-based PET Attenuation Correction Method for Neurological Studies on the MR-PET Brain Prototype

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J.; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A. Gregory

    2013-01-01

    A number of factors have to be considered for implementing an accurate attenuation correction (AC) in a combined MR-PET scanner. In this work, some of these challenges were investigated and an AC method based entirely on the MR data obtained with a single dedicated sequence was developed and used for neurological studies performed with the MR-PET human brain scanner prototype. Methods The focus was on the bone/air segmentation problem, the bone linear attenuation coefficient selection and the RF coil positioning. The impact of these factors on the PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultra-short echo time (DUTE) MR sequence was proposed for head imaging. Simultaneous MR-PET data were acquired and the PET images reconstructed using the proposed MR-DUTE-based AC method were compared with the PET images reconstructed using a CT-based AC. Results Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm−1 to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. Based on these results, the segmented CT AC method was established as the “silver standard” for the segmented MR-based AC method. Particular to an integrated MR-PET scanner, ignoring the RF coil attenuation can cause large underestimations (i.e. up to 50%) in the reconstructed images. Furthermore, the coil location in the PET field of view has to be accurately known. Good quality bone/air segmentation can be performed using the DUTE data. The PET images obtained using the MR-DUTE- and CT-based AC methods compare favorably in most of the brain structures. Conclusion An MR-DUTE-based AC

  16. Toward implementing an MRI-based PET attenuation-correction method for neurologic studies on the MR-PET brain prototype.

    Science.gov (United States)

    Catana, Ciprian; van der Kouwe, Andre; Benner, Thomas; Michel, Christian J; Hamm, Michael; Fenchel, Matthias; Fischl, Bruce; Rosen, Bruce; Schmand, Matthias; Sorensen, A Gregory

    2010-09-01

    Several factors have to be considered for implementing an accurate attenuation-correction (AC) method in a combined MR-PET scanner. In this work, some of these challenges were investigated, and an AC method based entirely on the MRI data obtained with a single dedicated sequence was developed and used for neurologic studies performed with the MR-PET human brain scanner prototype. The focus was on the problem of bone-air segmentation, selection of the linear attenuation coefficient for bone, and positioning of the radiofrequency coil. The impact of these factors on PET data quantification was studied in simulations and experimental measurements performed on the combined MR-PET scanner. A novel dual-echo ultrashort echo time (DUTE) MRI sequence was proposed for head imaging. Simultaneous MR-PET data were acquired, and the PET images reconstructed using the proposed DUTE MRI-based AC method were compared with the PET images that had been reconstructed using a CT-based AC method. Our data suggest that incorrectly accounting for the bone tissue attenuation can lead to large underestimations (>20%) of the radiotracer concentration in the cortex. Assigning a linear attenuation coefficient of 0.143 or 0.151 cm(-1) to bone tissue appears to give the best trade-off between bias and variability in the resulting images. Not identifying the internal air cavities introduces large overestimations (>20%) in adjacent structures. On the basis of these results, the segmented CT AC method was established as the silver standard for the segmented MRI-based AC method. For an integrated MR-PET scanner, in particular, ignoring the radiofrequency coil attenuation can cause large underestimations (i.e., PET field of view has to be accurately known. High-quality bone-air segmentation can be performed using the DUTE data. The PET images obtained using the DUTE MRI- and CT-based AC methods compare favorably in most of

  17. A prototype PET/SPECT/X-rays scanner dedicated for whole body small animal studies.

    Science.gov (United States)

    Rouchota, Maritina; Georgiou, Maria; Fysikopoulos, Eleftherios; Fragogeorgi, Eirini; Mikropoulos, Konstantinos; Papadimitroulas, Panagiotis; Kagadis, George; Loudos, George

    2017-01-01

    To present a prototype tri-modal imaging system, consisting of a single photon emission computed tomography (SPET), a positron emission tomography (PET), and a computed tomography (CT) subsystem, evaluated in planar mode. The subsystems are mounted on a rotating gantry, so as to be able to allow tomographic imaging in the future. The system, designed and constructed by our group, allows whole body mouse imaging of competent performance and is currently, to the best of our knowledge, unequaled in a national and regional level. The SPET camera is based on two Position Sensitive Photomultiplier Tubes (PSPMT), coupled to a pixilated Sodium Iodide activated with Thallium (NaI(Tl)) scintillator, having an active area of 5x10cm 2 . The dual head PET camera is also based on two pairs of PSPMT, coupled to pixelated berillium germanium oxide (BGO) scintillators, having an active area of 5x10cm 2 . The X-rays system consists of a micro focus X-rays tube and a complementary metal-oxide-semiconductor (CMOS) detector, having an active area of 12x12cm 2 . The scintigraphic mode has a spatial resolution of 1.88mm full width at half maximum (FWHM) and a sensitivity of 107.5cpm/0.037MBq at the collimator surface. The coincidence PET mode has an average spatial resolution of 3.5mm (FWHM) and a peak sensitivity of 29.9cpm/0.037MBq. The X-rays spatial resolution is 3.5lp/mm and the contrast discrimination function value is lower than 2%. A compact tri-modal system was successfully built and evaluated for planar mode operation. The system has an efficient performance, allowing accurate and informative anatomical and functional imaging, as well as semi-quantitative results. Compared to other available systems, it provides a moderate but comparable performance, at a fraction of the cost and complexity. It is fully open, scalable and its main purpose is to support groups on a national and regional level and provide an open technological platform to study different detector components and

  18. Correlation between tumour characteristics, SUV measurements, metabolic tumour volume, TLG and textural features assessed with 18F-FDG PET in a large cohort of oestrogen receptor-positive breast cancer patients.

    Science.gov (United States)

    Lemarignier, Charles; Martineau, Antoine; Teixeira, Luis; Vercellino, Laetitia; Espié, Marc; Merlet, Pascal; Groheux, David

    2017-07-01

    The study was designed to evaluate 1) the relationship between PET image textural features (TFs) and SUVs, metabolic tumour volume (MTV), total lesion glycolysis (TLG) and tumour characteristics in a large prospective and homogenous cohort of oestrogen receptor-positive (ER+) breast cancer (BC) patients, and 2) the capability of those parameters to predict response to neoadjuvant chemotherapy (NAC). 171 consecutive patients with large or locally advanced ER+ BC without distant metastases underwent an 18 F-FDG PET examination before NAC. The primary tumour was delineated with an adaptive threshold segmentation method. Parameters of volume, intensity and texture (entropy, homogeneity, contrast and energy) were measured and compared with tumour characteristics determined on pre-treatment breast biopsy (Wilcoxon rank-sum test). The correlation between PET-derived parameters was determined using Spearman's coefficient. The relationship between PET features and pathological findings was determined using the Wilcoxon rank-sum test. Spearman's coefficients between SUV max and TFs were 0.43, 0.24, -0.43 and -0.15 respectively for entropy, homogeneity, energy and contrast; they were higher between MTV and TFs: 0.99, 0.86, -0.99 and -0.87. All TFs showed a significant association with the histological type (IDC vs. ILC; 0.02 < P < 0.03) but didn't with immunohistochemical characteristics. SUV max and TLG predicted the pathological response (P = 0.0021 and P = 0.02 respectively); TFs didn't (P: 0.27, 0.19, 0.94, 0.19 respectively for entropy, homogeneity, energy and contrast). The correlation of TFs was poor with SUV parameters and high with MTV. TFs showed a significant association with the histological type. Finally, while SUV max and TLG were able to predict response to NAC, TFs failed.

  19. Feasibility of a novel design of high resolution parallax-free Compton enhanced PET scanner dedicated to brain research

    CERN Document Server

    Braem, André; Chesi, Enrico Guido; Correia, J G; Garibaldi, F; Joram, C; Mathot, S; Nappi, E; Ribeiro da Silva, M; Schoenahl, F; Séguinot, Jacques; Weilhammer, P; Zaidi, H

    2004-01-01

    A novel concept for a positron emission tomography (PET) camera module is proposed, which provides full 3D reconstruction with high resolution over the total detector volume, free of parallax errors. The key components are a matrix of long scintillator crystals and hybrid photon detectors (HPDs) with matched segmentation and integrated readout electronics. The HPDs read out the two ends of the scintillator package. Both excellent spatial (x, y, z) and energy resolution are obtained. The concept allows enhancing the detection efficiency by reconstructing a significant fraction of events which underwent Compton scattering in the crystals. The proof of concept will first be demonstrated with yttrium orthoaluminate perovskite (YAP):Ce crystals, but the final design will rely on other scintillators more adequate for PET applications (e.g. LSO:Ce or LaBr /sub 3/:Ce). A promising application of the proposed camera module, which is currently under development, is a high resolution 3D brain PET camera with an axial fi...

  20. A survey of PET activity in Germany during 1999

    International Nuclear Information System (INIS)

    Brix, Gunnar; Nosske, Dietmar; Minkov, Vladimir; Glatting, Gerhard; Reske, Sven N.

    2002-01-01

    Positron emission tomography (PET) is the most powerful molecular imaging technique currently available for clinical use. The aim of this study was to provide public health information on PET procedures carried out in Germany - a country with a very high number of PET installations. To this end, all facilities that in 1999 were running at least one dedicated PET system were contacted and requested to provide information in a questionnaire on the radiopharmaceuticals applied, the total number and age distribution of patients and volunteers examined, the main diagnostic applications and the range of administered activities. Based on the information provided by 48 of the 60 PET facilities in Germany, an annual frequency of about 0.34 PET procedures per 1,000 inhabitants was estimated, associated with an annual per capita effective dose of about 1.9 μSv. Averaged over all PET procedures, the mean effective dose to patients was 5.6 mSv. The age distribution of patients and volunteers was skewed markedly towards higher ages; only a very small fraction ( 18 F]fluoro-2-deoxy-D-glucose (FDG), which was utilised in more than 84% of all PET procedures. For this tracer, the median value for activities applied for examinations in the three-dimensional (3D) acquisition mode was only half of that used for two-dimensional (2D) measurements. Based on a statistical analysis of the distribution of mean FDG activities administered to patients in the 48 PET facilities who responded to our inquiry, diagnostic reference levels of 370 and 200 MBq are proposed for the 2D and the 3D mode, respectively. (orig.)

  1. Molecular markers in breast cancer: new tools in imaging and prognosis

    NARCIS (Netherlands)

    Vermeulen, J.F.

    2012-01-01

    Breast cancer is the most frequently diagnosed cancer in women. Although breast cancer is mainly diagnosed by mammography, other imaging modalities (e.g. MRI, PET) are increasingly used. The most recent developments in the field of molecular imaging comprise the application of near-infrared

  2. Health Examination by PET. (1) Cancer Examination

    International Nuclear Information System (INIS)

    Uno, Koichi

    2006-01-01

    Cancer examination by positron emission tomography (PET) started in Japan in 1994 and has been rapidly popularized. This paper describes author's experience of the examination in his hospital along the recent Japanese guideline for the PET cancer examination. Fluorodeoxyglucose (FDG) is intravenously injected at 3.7 (or 4.6, for diabetic patients) MBq/kg after 4-5 hr fasting and 40 min later, imaging is conducted with additional delayed scan at 2 hr to reduce the possible false positive. Image is taken by the equipment with PET-specific camera, of which quality assurance (QA) is maintained according to the guideline, and 3D image is constructed by the ordered subset expectation maximization method. Number of examinees during 4.5 years are 18,210 (M/F=9,735/8,475), and 236 (1.3%), together with use of other test measures like ultrasonography, computed tomography (CT), magnetic resonance imaging (MRI), biochemical marker and occult blood as well, are found to have cancer of thyroid, large bowel, lung, breast and others. The false negative rate by PET alone is 78/236 (33%) for cancer. PET examination has problems of image reading and specificity of organs, and tasks of informed consent, test cost, increased exchange of information and radiation exposure. However, PET cancer examination will be established as a routine diagnostic tool when the accumulated evidence of early cancer detection is shown useful for improving the survival rate and for reducing the medicare cost. (T.I.)

  3. PET radiation exposure control for nurses

    International Nuclear Information System (INIS)

    Kawabata, Yumiko; Kikuta, Daisuke; Anzai, Taku

    2005-01-01

    Recently, the number of clinical PET centers is increasing all over Japan. For this reason, the monitoring and control of radiation exposure of employees, especially nurses, in PET-dedicated clinics and institutions are becoming very important issues for their health. We measured the radiation exposure doses of the nurses working at Nishidai Diagnostic Imaging Center, and analyzed the exposure data obtained from them. The exposure doses of the nurses were found to be 4.8 to 7.1 mSv between April 2003 and March 2004. We found that the nurses were mostly exposed to radiation when they had to have contact with patients received an FDG injection or they had trouble with the FDG automatic injection system. To keep radiation exposure of nurses to a minimum we reconfirmed that a proper application of the three principles of protection against radiation exposure was vital. (author)

  4. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    International Nuclear Information System (INIS)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander; Grueneisen, Johannes; Sawicki, Lino M.; Grafe, Hong; Forsting, Michael; Bockisch, Andreas; Umutlu, Lale

    2016-01-01

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  5. Hybrid imaging for detection of carcinoma of unknown primary: A preliminary comparison trial of whole-body PET/MRI versus PET/CT

    Energy Technology Data Exchange (ETDEWEB)

    Ruhlmann, Verena; Ruhlmann, Marcus; Bellendorf, Alexander [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Grueneisen, Johannes [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Sawicki, Lino M. [Department of Diagnostic and Interventional Radiology, University of Dusseldorf, Moorenstraße 5, 40225 Dusseldorf (Germany); Grafe, Hong [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Forsting, Michael [Department of Diagnostic and Interventional Radiology and Neuroradiology, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Bockisch, Andreas [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany); Umutlu, Lale, E-mail: verena.ruhlmann@uk-essen.de [Department of Nuclear Medicine, University Hospital Essen, University Duisburg-Essen, Hufelandstr. 55, 45122 Essen (Germany)

    2016-11-15

    Highlights: • Both 18F-FDG PET/CT and 18F-FDG PET/MRI provide a comparable diagnostic ability for detection of primary cancer and metastases in CUP-syndrome. • Both imaging methods showed comparably high lesion conspicuity and diagnostic confidence (superior assessment of cervical lesions in PET/MRI). • PET/MRI may serve as a powerful alternative, particularly for therapy monitoring or surveillance considering the long-term cumulative dose. - Abstract: Purpose: The aim of this study is to evaluate and compare the diagnostic potential of integrated whole-body [18F]FDG-PET/MRI to [18F]FDG-PET/CT for detection of a potential primary cancer and metastases in patients suspected for cancer of unknown primary (CUP). Methods: A total of 20 patients (15 male, 5 female, age 53 ± 13 years) suspect for CUP underwent a dedicated head and neck & whole-body [18F]FDG-PET/CT (Biograph mCT 128, Siemens Healthcare) and a subsequent simultaneous [18F]FDG-PET/MRI examination (Biograph mMR, Siemens Healthcare). Two readers rated the datasets (PET/CT; PET/MRI) regarding the detection of the primary cancer and metastases, lesion conspicuity (4-point ordinal scale) and diagnostic confidence (3-point ordinal scale). PET analysis comprised the assessment of maximum standardized uptake values (SUVmax) of all PET-positive lesions using volume of interest (VOI) analysis derived from the PET/CT and PET/MR datasets. All available data considering histology and imaging including prior and clinical follow-up examinations served as reference standard. Statistical analysis included comparison of mean values using Mann-Whitney U test and correlation of SUVmax using Pearson‘s correlation. Results: In 14 out of 20 patients 49 malignant lesions were present. The primary cancer could be correctly identified in 11/20 patients with both PET/CT and PET/MRI. PET/CT enabled the detection of a total 38 metastases, PET/MR respectively of 37 metastases (one lung metastasis <5mm was missed). PET/CT and

  6. A fast preamplifier concept for SiPM-based time-of-flight PET detectors

    NARCIS (Netherlands)

    Huizenga, J.; Seifert, S.; Schreuder, F.; Dendooven, P.; Löhner, H.; Vinke, R.; Schaart, D. R.; van Dam, H.T.

    2012-01-01

    Silicon photomultipliers (SiPMs) offer high gain and fast response to light, making them interesting for fast timing applications such as time-of-flight (TOF) PET. To fully exploit the potential of these photosensors, dedicated preamplifiers that do not deteriorate the rise time and signal-to-noise

  7. Correlation between tumour characteristics, SUV measurements, metabolic tumour volume, TLG and textural features assessed with {sup 18}F-FDG PET in a large cohort of oestrogen receptor-positive breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Lemarignier, Charles; Groheux, David [Saint-Louis Hospital, Assistance Publique - Hopitaux de Paris, Department of Nuclear Medicine, Paris (France); University Sorbonne Paris Cite, INSERM/CNRS UMR944/7212, Paris (France); Martineau, Antoine; Vercellino, Laetitia; Merlet, Pascal [Saint-Louis Hospital, Assistance Publique - Hopitaux de Paris, Department of Nuclear Medicine, Paris (France); Teixeira, Luis; Espie, Marc [Saint-Louis Hospital, Breast Diseases Unit, Paris (France); University Sorbonne Paris Cite, INSERM/CNRS UMR944/7212, Paris (France)

    2017-07-15

    The study was designed to evaluate 1) the relationship between PET image textural features (TFs) and SUVs, metabolic tumour volume (MTV), total lesion glycolysis (TLG) and tumour characteristics in a large prospective and homogenous cohort of oestrogen receptor-positive (ER+) breast cancer (BC) patients, and 2) the capability of those parameters to predict response to neoadjuvant chemotherapy (NAC). 171 consecutive patients with large or locally advanced ER+ BC without distant metastases underwent an {sup 18}F-FDG PET examination before NAC. The primary tumour was delineated with an adaptive threshold segmentation method. Parameters of volume, intensity and texture (entropy, homogeneity, contrast and energy) were measured and compared with tumour characteristics determined on pre-treatment breast biopsy (Wilcoxon rank-sum test). The correlation between PET-derived parameters was determined using Spearman's coefficient. The relationship between PET features and pathological findings was determined using the Wilcoxon rank-sum test. Spearman's coefficients between SUV{sub max} and TFs were 0.43, 0.24, -0.43 and -0.15 respectively for entropy, homogeneity, energy and contrast; they were higher between MTV and TFs: 0.99, 0.86, -0.99 and -0.87. All TFs showed a significant association with the histological type (IDC vs. ILC; 0.02 < P < 0.03) but didn't with immunohistochemical characteristics. SUV{sub max} and TLG predicted the pathological response (P = 0.0021 and P = 0.02 respectively); TFs didn't (P: 0.27, 0.19, 0.94, 0.19 respectively for entropy, homogeneity, energy and contrast). The correlation of TFs was poor with SUV parameters and high with MTV. TFs showed a significant association with the histological type. Finally, while SUV{sub max} and TLG were able to predict response to NAC, TFs failed. (orig.)

  8. Solitary pulmonary nodules: accuracy and cost-effectiveness of sodium iodide FDG-PET using Australian data

    International Nuclear Information System (INIS)

    Keith, C.J.; Miles, K.A.; Griffiths, M.R.; Wong, D.; Pitman, A.G.; Hicks, R.J.

    2002-01-01

    This study uses Australian data to confirm the accuracy of dedicated sodium iodide (NaI) fluorine-18 fluorodeoxyglucose positron emission tomography (FDG-PET) in evaluating indeterminate solitary pulmonary nodules (SPNs) and to determine the conditions under which PET could play a cost-effective role in this evaluation. Ninety-two patients from two Australian hospitals in different states underwent FDG-PET for evaluation of an SPN. Observed values for prior probability of malignancy and diagnostic accuracy of PET were applied to previously published decision tree models using published Australian health care costs. The accuracy of FDG-PET was 93% with a sensitivity of 92% and a specificity of 95%. The prior probability of malignancy (0.54), PET sensitivity and PET specificity indicated cost savings per patient of up to EUR 455 (A$ 774) based on a PET cost of EUR 706 (A$ 1,200). PET would remain cost-effective for levels of prior probability up to 0.8-0.9 and a PET cost of EUR 736-1,161 (A$ 1,252-A$ 1,974). It is concluded that NaI PET is accurate, cost saving and cost-effective for the characterisation of indeterminate pulmonary nodules in Australia. Comparison with previous reports from the United States confirms that FDG-PET can remain cost-effective despite population differences in medical costs, disease prevalence and PET diagnostic performance. (orig.)

  9. Routine use of standard breast MRI compared to axillary ultrasound for differentiating between no, limited and advanced axillary nodal disease in newly diagnosed breast cancer patients

    Energy Technology Data Exchange (ETDEWEB)

    Nijnatten, T.J.A. van, E-mail: Thiemovn@gmail.com [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Ploumen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Schipper, RJ. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Catharina Hospital, Eindhoven (Netherlands); Goorts, B. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); GROW – School for Oncology and Developmental Biology, Maastricht University Medical Center+, Maastricht (Netherlands); Andriessen, E.H. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Department of Surgery, Maastricht University Medical Center+, Maastricht (Netherlands); Vanwetswinkel, S.; Schavemaker, M. [Department of Radiology and Nuclear Medicine, Maastricht University Medical Center+, Maastricht (Netherlands); Nelemans, P. [Department of Epidemiology, Maastricht University Medical Center+, Maastricht (Netherlands); Vries, B. de [Department of Pathology, Zuyderland Hospital, Heerlen (Netherlands); and others

    2016-12-15

    Objectives: To compare standard breast MRI to dedicated axillary ultrasound (with or without tissue sampling) for differentiating between no, limited and advanced axillary nodal disease in breast cancer patients. Methods: All patients who underwent breast MRI and dedicated axillary ultrasound between 2009 and 2014 were eligible. Exclusion criteria were recurrent disease, neoadjuvant systemic therapy and not receiving completion axillary lymph node dissection after positive sentinel lymph node biopsy (SLNB). Two radiologists independently reassessed all MRI exams. Axillary ultrasound findings were retrospectively collected. Probability of advanced axillary nodal disease (pN2-3) given clinically node negative (cN0) or limited (cN1) findings was calculated, with corresponding negative predictive value (NPV) to exclude pN2-3 and positive predictive value (PPV) to identify axillary nodal disease. Histopathology served as gold standard. Results: A total of 377 cases resulted in 81.4% no, 14.4% limited and 4.2% advanced axillary nodal disease at final histopathology. Probability of pN2-3 given cN0 for breast MRI and axillary ultrasound was 0.7–0.9% versus 1.5% and probability of pN2-3 given cN1 was 11.6–15.4% versus 29.0%. When cN1 on breast MRI was observed, PPV to identify positive axillary nodal disease was 50.7% and 59.0%. Conclusions: Evaluation of axillary nodal status on standard breast MRI is comparable to dedicated axillary ultrasound in breast cancer patients. In patients who underwent preoperative standard breast MRI, axillary ultrasound is only required in case of suspicious nodal findings on MRI.

  10. A PET Prototype for “In-Beam” Monitoring of Proton Therapy

    Science.gov (United States)

    Vecchio, Sara; Attanasi, Francesca; Belcari, Nicola; Camarda, Manuela; Cirrone, G. A. Pablo; Cuttone, Giacomo; Di Rosa, Francesco; Lanconelli, Nico; Moehrs, Sascha; Rosso, Valeria; Russo, Giorgio; Del Guerra, Alberto

    2009-02-01

    The in-beam PET is a novel PET application to image the beta+ activity induced in biological tissues by hadronic therapeutic beams. Thanks to the correlation existing between beam-delivered dose profiles and beam-induced activity profiles, in vivo information about the effective ion paths can be extracted from the in-beam pet image. in situ measurements, immediately after patient irradiation, are recommended in order to exploit the maximum statistics, by also detecting the contribution provided by the very short lived isotopes, e.g. 15O. A compact, dedicated tomograph should then be developed for such an application, so as to be used in the treatment room. We developed a small PET prototype in order to demonstrate the feasibility of such a technique for the monitoring of proton therapy of ocular tumors at the CATANA facility (Catania, Italy). The prototype consists of two planar heads with an active area of about 5 cm times 5 cm. Each head is made up of a square position sensitive photomultiplier (Hamamatsu H8500) coupled to a matrix of the same size of LYSO scintillating crystals (2 mm times 2 mm times 18 mm pixel dimensions). Dedicated, compact electronic boards are used for the signal multiplexing, amplification and digitization. The distance between the pair can be varied from 10 cm up to a maximum of about 20 cm. The validation of the prototype was performed on plastic phantoms using 62 MeV protons at the CATANA beam line. Different dose distributions were delivered and a good correlation between the distal fall-off of the activity profiles and of the dose profiles was found, i.e., better than 2 mm along the beam direction.

  11. Combined PET/MR: The Real Work Has Just Started. Summary Report of the Third International Workshop on PET/MR Imaging; February 17-21, 2014, Tübingen, Germany.

    Science.gov (United States)

    Bailey, D L; Antoch, G; Bartenstein, P; Barthel, H; Beer, A J; Bisdas, S; Bluemke, D A; Boellaard, R; Claussen, C D; Franzius, C; Hacker, M; Hricak, H; la Fougère, C; Gückel, B; Nekolla, S G; Pichler, B J; Purz, S; Quick, H H; Sabri, O; Sattler, B; Schäfer, J; Schmidt, H; van den Hoff, J; Voss, S; Weber, W; Wehrl, H F; Beyer, T

    2015-06-01

    This paper summarises the proceedings and discussions at the third annual workshop held in Tübingen, Germany, dedicated to the advancement of the technical, scientific and clinical applications of combined PET/MRI systems in humans. Two days of basic scientific and technical instructions with "hands-on" tutorials were followed by 3 days of invited presentations from active researchers in this and associated fields augmented by round-table discussions and dialogue boards with specific themes. These included the use of PET/MRI in paediatric oncology and in adult neurology, oncology and cardiology, the development of multi-parametric analyses, and efforts to standardise PET/MRI examinations to allow pooling of data for evaluating the technology. A poll taken on the final day demonstrated that over 50 % of those present felt that while PET/MRI technology underwent an inevitable slump after its much-anticipated initial launch, it was now entering a period of slow, progressive development, with new key applications emerging. In particular, researchers are focusing on exploiting the complementary nature of the physiological (PET) and biochemical (MRI/MRS) data within the morphological framework (MRI) that these devices can provide. Much of the discussion was summed up on the final day when one speaker commented on the state of PET/MRI: "the real work has just started".

  12. Markerless 3D Head Tracking for Motion Correction in High Resolution PET Brain Imaging

    DEFF Research Database (Denmark)

    Olesen, Oline Vinter

    relying on markers. Data-driven motion correction is problematic due to the physiological dynamics. Marker-based tracking is potentially unreliable, and it is extremely hard to validate when the tracking information is correct. The motion estimation is essential for proper motion correction of the PET......This thesis concerns application specific 3D head tracking. The purpose is to improve motion correction in position emission tomography (PET) brain imaging through development of markerless tracking. Currently, motion correction strategies are based on either the PET data itself or tracking devices...... images. Incorrect motion correction can in the worst cases result in wrong diagnosis or treatment. The evolution of a markerless custom-made structured light 3D surface tracking system is presented. The system is targeted at state-of-the-art high resolution dedicated brain PET scanners with a resolution...

  13. In-beam PET at high-energy photon beams: a feasibility study

    Science.gov (United States)

    Müller, H.; Enghardt, W.

    2006-04-01

    For radiation therapy with carbon ion beams, either for the stable isotope 12C or for the radioactive one 11C, it has been demonstrated that the β+-activity distribution created or deposited, respectively, within the irradiated volume can be visualized by means of positron emission tomography (PET). The PET images provide valuable information for quality assurance and precision improvement of ion therapy. Dedicated PET scanners have been integrated into treatment sites at the Heavy Ion Medical Accelerator at Chiba (HIMAC), Japan, and the Gesellschaft für Schwerionenforschung (GSI), Germany, to make PET imaging feasible during therapeutic irradiation (in-beam PET). A similar technique may be worthwhile for radiotherapy with high-energy bremsstrahlung. In addition to monitoring the dose delivery process which in-beam PET has been primarily developed for, it may be expected that radiation response of tissue can be detected by means of in-beam PET. We investigate the applicability of PET for treatment control in the case of using bremsstrahlung spectra produced by 15-50 MeV electrons. Target volume activation due to (γ, n) reactions at energies above 20 MeV yields moderate β+-activity levels, which can be employed for imaging. The radiation from positrons produced by pair production is not presently usable because the detectors are overloaded due to the low duty factor of medical electron linear accelerators. However, the degradation of images caused by positron motion between creation and annihilation seems to be tolerable.

  14. Radiotherapy may induce enhanced uptake on F-18-fluoroestradiol PET scans

    NARCIS (Netherlands)

    Venema, C. M.; Veen, van der S. J.; Glaudemans, A. W. J. M.; Schroder, C. P.; de Vries, E. F. J.; Hospers, G. A. P.

    2016-01-01

    Introduction: Whole body imaging of 18F-fluoroestradiol (FES) uptake combined with positron emission tomography (PET) has been applied for diagnosis and prediction of therapy response in estrogen receptor (ER) positive breast cancer patients. A maximal standardized uptake value (SUVmax) of 1.5 has

  15. FDG-PET identification of intraperitoneal metastases

    International Nuclear Information System (INIS)

    Gamez, C.; Jimenez-Hoyuelam, J.M.; Rebollo, A.C.; Gonzalez, P.; Rico, J.M.; Alba, E.; Sacchetti, A.; Lopez-Rueda, B.

    2002-01-01

    Aim: Peritoneal metastases (PM) are usually from intra-abdominal primary neoplasms, such as carcinoma of the stomach, colon, ovary, and pancreas, or from intra-abdominal lymphoma. Metastases disseminate throughout the peritoneum in four ways: 1) direct spread along peritoneal ligaments, mesenteries and omenta; 2) via the flow of ascitis fluid. 3) lymphatic extension, and 4) embolic hematogenous spread. Although CT is quite specific in identifying PM it is not very sensitive, and peritoneal lavage or biopsy can be very useful but have sampling errors. This study assessed the clinical value of FDG-PET for the detection of PM of malignant diseases. Materials and Methods: 15 FDG-PET scans of patients referred for recurrence (mean age = 54 y/o, sex = 6M, 9F), with metabolic abnormalities suspicious findings of PM from carcinoma of the colon (7), ovary (3), lymphoma (2), pancreas (1), gastrointestinal stromal tumor (1) and melanoma (1) were reviewed. The whole-body studies were performed 50 min following the intravenous administration of 370 MBq of 18F-FDG, in a high resolution dedicated PET scanner (Advance, GEMS), with images reconstructed using a iterative algorithm with segmented attenuation correction. Visual interpretation and SUV values were correlated with CT/MRI findings and biopsy/follow-up. Results: Of the 15 patients, 7 showed <3 sites of focal uptake and 8 presented multiple foci or a diffuse hypermetabolism in the abdomen (SUVmax3.04-18.83 g/ml). 6 patients had biopsy confirmation by PET-directed surgery (6 proven PM, 0 negative biopsies). 11 FDG-PET scans had correspondence with the CT/MRI findings and 4 showed discrepancies (PET positive-CT/MRI negative in patients with isolated raising tumor markers levels or unsuspected PM). FDG-PET influenced the therapeutic management in 2 patients as presented multiple metastases leading them from surgery to chemotherapy. Conclusion: When used as a complementary imaging tool to the conventional work up, FDG-PET is

  16. WE-AB-204-03: A Novel 3D Printed Phantom for 4D PET/CT Imaging and SIB Radiotherapy Verification

    International Nuclear Information System (INIS)

    Soultan, D; Murphy, J; Moiseenko, V; Cervino, L; Gill, B

    2015-01-01

    Purpose: To construct and test a 3D printed phantom designed to mimic variable PET tracer uptake seen in lung tumor volumes. To assess segmentation accuracy of sub-volumes of the phantom following 4D PET/CT scanning with ideal and patient-specific respiratory motion. To plan, deliver and verify delivery of PET-driven, gated, simultaneous integrated boost (SIB) radiotherapy plans. Methods: A set of phantoms and inserts were designed and manufactured for a realistic representation of lung cancer gated radiotherapy steps from 4D PET/CT scanning to dose delivery. A cylindrical phantom (40x 120 mm) holds inserts for PET/CT scanning. The novel 3D printed insert dedicated to 4D PET/CT mimics high PET tracer uptake in the core and lower uptake in the periphery. This insert is a variable density porous cylinder (22.12×70 mm), ABS-P430 thermoplastic, 3D printed by uPrint SE Plus with inner void volume (5.5×42 mm). The square pores (1.8×1.8 mm2 each) fill 50% of outer volume, resulting in a 2:1 SUV ratio of PET-tracer in the void volume with respect to porous volume. A matching in size cylindrical phantom is dedicated to validate gated radiotherapy. It contains eight peripheral holes matching the location of the porous part of the 3D printed insert, and one central hole. These holes accommodate adaptors for Farmer-type ion chamber and cells vials. Results: End-to-end test were performed from 4D PET/CT scanning to transferring data to the planning system and target volume delineation. 4D PET/CT scans were acquired of the phantom with different respiratory motion patterns and gating windows. A measured 2:1 18F-FDG SUV ratio between inner void and outer volume matched the 3D printed design. Conclusion: The novel 3D printed phantom mimics variable PET tracer uptake typical of tumors. Obtained 4D PET/CT scans are suitable for segmentation, treatment planning and delivery in SIB gated treatments of NSCLC

  17. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer.

    Science.gov (United States)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-03-01

    To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient's staging and treatment planning. 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen's kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p=0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  18. Radiation dose to radiosensitive organs in PET/CT myocardial perfusion examination using versatile optical fibre

    Science.gov (United States)

    Salasiah, M.; Nordin, A. J.; Fathinul Fikri, A. S.; Hishar, H.; Tamchek, N.; Taiman, K.; Ahmad Bazli, A. K.; Abdul-Rashid, H. A.; Mahdiraji, G. A.; Mizanur, R.; Noor, Noramaliza M.

    2013-05-01

    Cardiac positron emission tomography (PET) provides a precise method in order to diagnose obstructive coronary artery disease (CAD), compared to single photon emission tomography (SPECT). PET is suitable for obese and patients who underwent pharmacologic stress procedures. It has the ability to evaluate multivessel coronary artery disease by recording changes in left ventricular function from rest to peak stress and quantifying myocardial perfusion (in mL/min/g of tissue). However, the radiation dose to the radiosensitive organs has become crucial issues in the Positron Emission Tomography/Computed Tomography(PET/CT) scanning procedure. The objective of this study was to estimate radiation dose to radiosensitive organs of patients who underwent PET/CT myocardial perfusion examination at Centre for Diagnostic Nuclear Imaging, Universiti Putra Malaysia in one month period using versatile optical fibres (Ge-B-doped Flat Fibre) and LiF (TLD-100 chips). All stress and rest paired myocardial perfusion PET/CT scans will be performed with the use of Rubidium-82 (82Rb). The optic fibres were loaded into plastic capsules and attached to patient's eyes, thyroid and breasts prior to the infusion of 82Rb, to accommodate the ten cases for the rest and stress PET scans. The results were compared with established thermoluminescence material, TLD-100 chips. The result shows that radiation dose given by TLD-100 and Germanium-Boron-doped Flat Fiber (Ge-B-doped Flat Fiber) for these five organs were comparable to each other where the p>0.05. For CT scans,thyroid received the highest dose compared to other organs. Meanwhile, for PET scans, breasts received the highest dose.

  19. Perfusion CT compared to H{sub 2}{sup 15}O/O{sup 15}O PET in patients with chronic cervical carotid artery occlusion

    Energy Technology Data Exchange (ETDEWEB)

    Kamath, Amita; Chien, Jeffrey D.; Dillon, William P.; Wintermark, Max [University of California, San Francisco, Department of Radiology, Neuroradiology Section, San Francisco, CA (United States); Smith, Wade S. [University of California, Department of Neurology, San Francisco, CA (United States); Powers, William J. [University of North Carolina, Department of Neurology, Chapel Hill, NC (United States); Cianfoni, Alessandro [Catholic University of Sacred Heart, Department of Bioimages and Radiological Sciences, Rome (Italy); Videen, Tom [Washington University School of Medicine, Departments of Neurology and Radiology, St. Louis, MO (United States); Lawton, Michael T. [University of California, San Francisco, CA (United States). Department of Neurosurgery; Finley, Bruce [Northern California PET Imaging Center, Sacramento, CA (United States)

    2008-09-15

    The purpose of this study was to compare the results of perfusion computed tomography (PCT) with those of {sup 15}O{sub 2}/H{sub 2}{sup 15}O positron emission tomography (PET) in a subset of Carotid Occlusion Surgery Study (COSS) patients. Six patients enrolled in the COSS underwent a standard-of-care PCT in addition to the {sup 15}O{sub 2}/H{sub 2}{sup 15}O PET study used for selection for extracranial-intracranial bypass surgery. PCT and PET studies were coregistered and then processed separately by different radiologists. Relative measurement of cerebral blood flow (CBF) and oxygen extraction fraction (OEF) were calculated from PET. PCT datasets were processed using different arterial input functions (AIF). Relative PCT and PET CBF values from matching regions of interest were compared using linear regression model to determine the most appropriate arterial input function for PCT. Also, PCT measurements using the most accurate AIF were evaluated for linear regression with respect to relative PET OEF values. The most accurate PCT relative CBF maps with respect to the gold standard PET CBF were obtained when CBF values for each arterial territory are calculated using a dedicated AIF for each territory (R{sup 2}=0.796, p<0.001). PCT mean transit time (MTT) is the parameter that showed the best correlation with the count-based PET OEF ratios (R{sup 2}=0.590, p<0.001). PCT relative CBF compares favorably to PET relative CBF in patients with chronic carotid occlusion when processed using a dedicated AIF for each territory. The PCT MTT parameter correlated best with PET relative OEF. (orig.)

  20. Detection and compensation of organ/lesion motion using 4D-PET/CT respiratory gated acquisition techniques

    International Nuclear Information System (INIS)

    Bettinardi, Valentino; Picchio, Maria; Di Muzio, Nadia; Gianolli, Luigi; Gilardi, Maria Carla; Messa, Cristina

    2010-01-01

    Purpose: To describe the degradation effects produced by respiratory organ and lesion motion on PET/CT images and to define the role of respiratory gated (RG) 4D-PET/CT techniques to compensate for such effects. Methods: Based on the literature and on our own experience, technical recommendations and clinical indications for the use of RG 4D PET/CT have been outlined. Results: RG 4D-PET/CT techniques require a state of the art PET/CT scanner, a respiratory monitoring system and dedicated acquisition and processing protocols. Patient training is particularly important to obtain a regular breathing pattern. An adequate number of phases has to be selected to balance motion compensation and statistical noise. RG 4D PET/CT motion free images may be clinically useful for tumour tissue characterization, monitoring patient treatment and target definition in radiation therapy planning. Conclusions: RG 4D PET/CT is a valuable tool to improve image quality and quantitative accuracy and to assess and measure organ and lesion motion for radiotherapy planning.

  1. The assessment of breast cancer response to neoadjuvant chemotherapy: comparison of magnetic resonance imaging and 18F-fluorodeoxyglucose positron emission tomography

    International Nuclear Information System (INIS)

    Park, Jeong Seon; Moon, Woo Kyung; Lyou, Chae Yeon; Cho, Nariya; Kang, Keon Wook; Chung, June-Key

    2011-01-01

    Background: Neoadjuvant chemotherapy for locally advanced breast cancer is a widely accepted treatment. For assessment of the tumor response after chemotherapy, both magnetic resonance imaging (MRI) and 18 F-fluorodeoxyglucose positron emission tomography (PET) are promising methods. Purpose: To retrospectively compare MRI and PET in the assessment of tumor response to neoadjuvant chemotherapy for primary breast cancer with the pathologic response as the reference standard. Material and Methods: Between August 2006 and May 2008, 32 women with breast cancer underwent concurrent MRI and PET before and after neoadjuvant chemotherapy. For response assessment, we calculated the changes in the maximum diameters of the tumor (ΔDmax) on MRI, and the changes in the standard uptake values (ΔSUV) on PET. The correlation between the ΔDmax and ΔSUV was analyzed using Pearson's correlation coefficient. The correspondence rates between each imaging modality and pathologic assessment were calculated. For prediction of the pathologic complete response (pCR), the sensitivity, specificity, positive predictive value (PPV) and negative predictive value (NPV) were analyzed using the McNemar test. Results: The pathologic assessment of tumor response to neoadjuvant chemotherapy identified eight complete responses (25.0%), 10 partial responses (31.2%), and 14 non-responses (43.8%). The change in size on MRI was moderately correlated with the change in SUV on PET (r = 0.574, p = 0.001). The correspondence rate of response assessment was 75.0% (24/32) between MRI and pathologic response and 53.1% (17/32) between PET and pathologic response. For the pCR, specificity (95.8% vs. 62.5%) and PPV (83.3% vs. 47.1%) were statistically higher on MRI than PET (p < 0.05), while sensitivity (100.0% vs. 62.5%) and NPV (100.0% vs. 88.5%) on PET tended to be higher than MRI. Conclusion: Before and after neoadjuvant chemotherapy for breast cancer, the ΔDmax of MRI correlated moderately with the

  2. Automated analysis of PET based in-vivo monitoring in ion beam therapy

    International Nuclear Information System (INIS)

    Kuess, P.

    2014-01-01

    experimental data two dedicated phantoms were irradiated with 12C-beams and subsequently monitored with the in-beam PET prototype at GSI. Additionally these experimental data were used to compare the PCC based algorithm with a range comparison algorithm developed at the TUD Dresden. The lower limit of detecting range uncertainties for H&N patients was 4 mm. The same value was found for the detection of setup uncertainties for H&N cases. Regarding smaller lesions in heterogeneous tissue (e.g. lung) a detection down to 2 mm was possible. A deviation detection in homogeneous tissue (e.g. pelvic area) remained challenging, especially due to very similar tissue components the PT-PET images for such anatomic regions are too much alike. The testing of the PCC based algorithm in dedicated phantoms revealed that a range deviation of 2 mm and more could be detected automatically. Filled cavities could be successfully detected if their diameter was at least 5 mm. The obtained results demonstrated that the automated comparison of BADs provides similar results as visual inspections. The capability of automatically detecting patient setup errors using PT-PET demonstrates the wide applicability of this technique. The investigations performed in different anatomic regions with different tissue compositions demonstrated both the potential and the limitations of PT-PET in general and of the automated evaluation tool in particular. With the design of dedicated phantoms and the subsequent acquired experimental PT-PET data an objective measure is given to test the evaluation software. In conclusion the developed software tool has the potential to reduce the clinical workload essentially so that the implementation of PT-PET in the clinical routine becomes a promising verification option for future PT treatments. Further development of the software tool has to be performed in a clinical environment with the possibility to test the automated comparison for larger cohorts with similar patient

  3. Atlas of PET/MR imaging in oncology

    International Nuclear Information System (INIS)

    Ratib, Osman; Schwaiger, Markus; Beyer, Thomas

    2013-01-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  4. Atlas of PET/MR imaging in oncology

    Energy Technology Data Exchange (ETDEWEB)

    Ratib, Osman [University Hospital of Geneva (Switzerland). Nuclear Medicine Division; Schwaiger, Markus [Technische Univ. Muenchen (Germany). Nuklearmedizinische Klinik und Poliklinik; Beyer, Thomas (eds.) [General Hospital Vienna (Austria). Center for Medical Physics and Biomedical Engineering

    2013-08-01

    Numerous illustrated clinical cases in different oncology domains. Includes digital interactive software matching the cases in the book. Interactive version based on the latest web standard, HTML5, ensuring the widest compatibility. Edited by three international opinion leaders/imaging experts in the field. This new project on PET/MR imaging in oncology includes digital interactive software matching the cases in the book. The interactive version of the atlas is based on the latest web standard, HTML5, ensuring compatibility with any computer operating system as well as a dedicated version for Apple iPad and iPhone. The book opens with an introduction to the principles of hybrid imaging that pays particular attention to PET/MR imaging and standard PET/MR acquisition protocols. A wide range of illustrated clinical case reports are then presented. Each case study includes a short clinical history, findings, and teaching points, followed by illustrations, legends, and comments. The multimedia version of the book includes dynamic movies that allow the reader to browse through series of rotating 3D images (MIP or volume rendered), display blending between PET and MR, and dynamic visualization of 3D image volumes. The movies can be played either continuously or sequentially for better exploration of sets of images. The editors of this state-of-the-art publication are key opinion leaders in the field of multimodality imaging. Professor Osman Ratib (Geneva) and Professor Markus Schwaiger (Munich) were the first in Europe to initiate the clinical adoption of PET/MR imaging. Professor Thomas Beyer (Zurich) is an internationally renowned pioneering physicist in the field of hybrid imaging. Individual clinical cases presented in this book are co-authored by leading international radiologists and nuclear physicians experts in the use of PET and MRI.

  5. FDG PET/CT features of ovarian metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Kitajima, K., E-mail: kitajima@med.kobe-u.ac.j [Department of PET Diagnosis, Institute of Biomedical Research and Innovation, Kobe (Japan); Suzuki, K. [Department of PET Diagnosis, Institute of Biomedical Research and Innovation, Kobe (Japan); Senda, M. [Department of Molecular Imaging, Institute of Biomedical Research and Innovation, Kobe (Japan); Kita, M. [Department of Obsterics and Gynecology, Kobe City Medical Center General Hospital, Kobe (Japan); Onishi, Y.; Maeda, T.; Yoshikawa, T.; Ohno, Y.; Sugimura, K. [Department of Radiology, Kobe University Graduate School of Medicine, Kobe (Japan)

    2011-03-15

    Aim: To assess the characteristics of [{sup 18}F]-fluoro-2-deoxy-D-glucose (FDG) uptake in cases of ovarian metastasis using positron-emission tomography/computed tomography (PET/CT). Materials and methods: Twelve patients with 16 ovarian metastases arising from colon cancer (n = 6), breast cancer (n = 4), gastric cancer (n = 3), and pancreatic cancer (n = 3) who underwent FDG-PET/CT examination were included in this study. The effect of lesion size and morphological pattern (predominantly solid or cystic) on FDG uptake was evaluated using the quantitative standardized uptake value (SUV). Results: The mean maximum SUV for the 16 lesions was 4.6 {+-} 2.4 (range 1.8 {approx} 9.9). The Pearson correlation coefficient test showed no significant correlation between maximum SUV and lesion size (r = 0.21, p = 0.42). The maximum SUV of solid (n = 5) and cystic (n = 11) lesions was 5.5 {+-} 2.7 and 4.3 {+-} 2.2, respectively, and the difference was not significant (p = 0.43). Breast cancer showed the highest maximum SUV (6.4 {+-} 3.6), followed by colon cancer (5.3 {+-} 1.4), gastric cancer (3.3 {+-} 0.5), and pancreatic cancer (2.2 {+-} 0.6). Conclusion: Ovarian metastases show a variable maximum SUV with mild to intense FDG uptake.

  6. Advanced Imaging and Receipt of Guideline Concordant Care in Women with Early Stage Breast Cancer

    Directory of Open Access Journals (Sweden)

    Elizabeth Trice Loggers

    2016-01-01

    Full Text Available Objective. It is unknown whether advanced imaging (AI is associated with higher quality breast cancer (BC care. Materials and Methods. Claims and Surveillance Epidemiology and End Results data were linked for women diagnosed with incident stage I-III BC between 2002 and 2008 in western Washington State. We examined receipt of preoperative breast magnetic resonance imaging (MRI or AI (defined as computed tomography [CT]/positron emission tomography [PET]/PET/CT versus mammogram and/or ultrasound (M-US alone and receipt of guideline concordant care (GCC using multivariable logistic regression. Results. Of 5247 women, 67% received M-US, 23% MRI, 8% CT, and 3% PET/PET-CT. In 2002, 5% received MRI and 5% AI compared to 45% and 12%, respectively, in 2008. 79% received GCC, but GCC declined over time and was associated with younger age, urban residence, less comorbidity, shorter time from diagnosis to surgery, and earlier year of diagnosis. Breast MRI was associated with GCC for lumpectomy plus radiation therapy (RT (OR 1.55, 95% CI 1.08–2.26, and p=0.02 and AI was associated with GCC for adjuvant chemotherapy for estrogen-receptor positive (ER+ BC (OR 1.74, 95% CI 1.17–2.59, and p=0.01. Conclusion. GCC was associated with prior receipt of breast MRI and AI for lumpectomy plus RT and adjuvant chemotherapy for ER+ BC, respectively.

  7. Multi-modality image reconstruction for dual-head small-animal PET

    International Nuclear Information System (INIS)

    Huang, Chang-Han; Chou, Cheng-Ying

    2015-01-01

    The hybrid positron emission tomography/computed tomography (PET/CT) or positron emission tomography/magnetic resonance imaging (PET/MRI) has become routine practice in clinics. The applications of multi-modality imaging can also benefit research advances. Consequently, dedicated small-imaging system like dual-head small-animal PET (DHAPET) that possesses the advantages of high detection sensitivity and high resolution can exploit the structural information from CT or MRI. It should be noted that the special detector arrangement in DHAPET leads to severe data truncation, thereby degrading the image quality. We proposed to take advantage of anatomical priors and total variation (TV) minimization methods to reconstruct PET activity distribution form incomplete measurement data. The objective is to solve the penalized least-squares function consisted of data fidelity term, TV norm and medium root priors. In this work, we employed the splitting-based fast iterative shrinkage/thresholding algorithm to split smooth and non-smooth functions in the convex optimization problems. Our simulations studies validated that the images reconstructed by use of the proposed method can outperform those obtained by use of conventional expectation maximization algorithms or that without considering the anatomical prior information. Additionally, the convergence rate is also accelerated.

  8. FDG PET in the diagnosis of meningeal carcinomatosis

    International Nuclear Information System (INIS)

    Guan, Y. H.; Zuo, C.T.; Zhao, J.; Hua, F.C.; Lin, X.T.

    2002-01-01

    Objective: Meningeal involvement is frequent in metastatic lymphoma, leukemia, and other metastatic tumor. Functional signs may be misleading and the neurological examination may be normal or non-specific. Certain diagnosis requires identification of tumor cells in the cerebrospinal fluid. CSF cytology is however sometimes negative and MRI maybe help in providing the diagnosis. The aim of our retrospective study was to assess the role of FDG PET in the diagnosis of meningeal carcinomatosis. Patients and Methods: The diagnosis of meningeal carcinomatosis was made in 5 patients between 1999 and 2001. Two of the patients were suffer from lymphoma, two were lung cancer patients, and another was a breast cancer patient. Cytology examination of the cerebrospinal fluid provided the diagnosis of meningeal carcinomatosis in these 5 patients. All the patients had signs of neurological function impairment, but the neurological examination cannot demonstrate the site of lesions. Therefore, All the patients had MRI examination, but only 1 case was diagnosis correctly (the MRI showing meningeal enhancement). 3 patients' MRI results show normal .Another MRI was suspicious of ischemic change. Results: A brain FDG PET using an ECAT HR + PET examined all the 5 patients. All the FDG PET results show the hypermetabolic foci respectively. The foci were diffused on the brain meninges. Their size is bigger than the foci detected by MRI . 3 of the patients repeated the FDG PET scan after treatment (chemotherapy and radiotherapy). The therapeutic effect can be reflecting by FDG PET (the foci dismissed as the neurological symptoms disappeared), although the simultaneity MRI shows no change before and after treatment. Conclusion: 5 patients proven meningeal carcinomatosis FDG PET has better sensitivity than brain MRI scans and other anatomic modality. The patients who suffer from metastatic lymphoma, leukemia, and other metastatic tumor with nonspecific neurological signs should be explored

  9. Decreased occipital lobe metabolism by FDG-PET/CT: An anti-NMDA receptor encephalitis biomarker.

    Science.gov (United States)

    Probasco, John C; Solnes, Lilja; Nalluri, Abhinav; Cohen, Jesse; Jones, Krystyna M; Zan, Elcin; Javadi, Mehrbod S; Venkatesan, Arun

    2018-01-01

    To compare brain metabolism patterns on fluorodeoxyglucose (FDG)-PET/CT in anti-NMDA receptor and other definite autoimmune encephalitis (AE) and to assess how these patterns differ between anti-NMDA receptor neurologic disability groups. Retrospective review of clinical data and initial dedicated brain FDG-PET/CT studies for neurology inpatients with definite AE, per published consensus criteria, treated at a single academic medical center over a 10-year period. Z-score maps of FDG-PET/CT were made using 3-dimensional stereotactic surface projections in comparison to age group-matched controls. Brain region mean Z scores with magnitudes ≥2.00 were interpreted as significant. Comparisons were made between anti-NMDA receptor and other definite AE patients as well as among patients with anti-NMDA receptor based on modified Rankin Scale (mRS) scores at the time of FDG-PET/CT. The medial occipital lobes were markedly hypometabolic in 6 of 8 patients with anti-NMDA receptor encephalitis and as a group (Z = -4.02, interquartile range [IQR] 2.14) relative to those with definite AE (Z = -2.32, 1.46; p = 0.004). Among patients with anti-NMDA receptor encephalitis, the lateral and medial occipital lobes were markedly hypometabolic for patients with mRS 4-5 (lateral occipital lobe Z = -3.69, IQR 1; medial occipital lobe Z = -4.08, 1) compared with those with mRS 0-3 (lateral occipital lobe Z = -0.83, 2; p occipital lobe Z = -1.07, 2; p = 0.001). Marked medial occipital lobe hypometabolism by dedicated brain FDG-PET/CT may serve as an early biomarker for discriminating anti-NMDA receptor encephalitis from other AE. Resolution of lateral and medial occipital hypometabolism may correlate with improved neurologic status in anti-NMDA receptor encephalitis.

  10. Multimodality assessment of breast tumor physiology and metabolism

    Science.gov (United States)

    Chaudhry, Muhammad; Rosen, Mark; Schultz, Susan; Englander, Sarah; Sehgal, S.; Tomaszewski, M.; Schnall, Mitchell

    2005-04-01

    The objective is to compare power Doppler sonography (PD) and dynamic contrast-enhanced MRI (MR) and PET SUV in assessing the vascularity of benign and malignant breast lesions. Sixty two patients with 89 lesions (59 malignant lesions, 30 benign lesions) were evaluated by PD, MRI (MR) and PET SUV prior to surgery. Each imaging modality was evaluated independently. Lesion vascularity on PD was graded as avascular, intermediately vascular, or hypervascular. On MR, degree of maximal enhancement (minimal, moderate, or marked) and the kinetic pattern of enhancement (persistent, plateau, washout) were graded separately. For malignant lesions, PET SUV values were correlated with MRI kinetics. Gamma variable analysis was performed to assess the degree of correlation. Of the 89 lesions 44 were invasive ductal carcinoma, 2 were intraductal cancers, 6 were invasive lobular carcinoma, and 7 were invasive cancers with mixture of ductal and lobular features. There was a high degree of correlation between degree of maximal enhancement and enhancement kinetics on MRI (G=0.074, pInvasive malignancy demonstrated moderate correlation between SUV and MRI kinetics (G=0.64, p=0.14). There is a variable degree of correlation between various imaging modalities in assessing breast lesion vascularity. Further evaluation on the relationship between subjective reader assessment and objective quantitative image analysis is required to elucidate the differences in these measures of breast tumor physiology. This work was supported in part by the NIH grant P01CA085424-03.

  11. Automation and Preclinical Evaluation of a Dedicated Emission Mammotomography System for Fully 3-D Molecular Breast Imaging

    National Research Council Canada - National Science Library

    Cutler, Spencer J

    2007-01-01

    .... A retrospective study of 103 clinical MRI uncompressed breast scans was conducted to create surface renderings of the uncompressed breasts and analyze how to adapt existing acquisition orbits for varying breast shapes...

  12. Novel design of a parallax free Compton enhanced PET scanner

    International Nuclear Information System (INIS)

    Braem, A.; Chamizo, M.; Chesi, E.; Colonna, N.; Cusanno, F.; De Leo, R.; Garibaldi, F.; Joram, C.; Marrone, S.; Mathot, S.; Nappi, E.; Schoenahl, F.; Seguinot, J.; Weilhammer, P.; Zaidi, H.

    2004-01-01

    Molecular imaging by PET is a powerful tool in modern clinical practice for cancer diagnosis. Nevertheless, improvements are needed with respect to the spatial resolution and sensitivity of the technique for its application to specific human organs (breast, prostate, brain, etc.), and to small animals. Presently, commercial PET scanners do not detect the depth of interaction of photons in scintillators, which results in a not negligible parallax error. We describe here a novel concept of PET scanner design that provides full three-dimensional (3D) gamma reconstruction with high spatial resolution over the total detector volume, free of parallax errors. It uses matrices of long scintillators read at both ends by hybrid photon detectors. This so-called 3D axial concept also enhances the gamma detection efficiency since it allows one to reconstruct a significant fraction of Compton scattered events. In this note, we describe the concept, a possible design and the expected performance of this new PET device. We also report about first characterization measurements of 10 cm long YAP:Ce scintillation crystals

  13. Clinical application of S-Detect to breast masses on ultrasonography: A study evaluating the diagnostic performance and agreement with a dedicated breast radiologist

    International Nuclear Information System (INIS)

    Kim, Ki Wook; Kim, Eun Kyung; Yoon, Jung Hyun; Song, Mi Kyung

    2017-01-01

    The purpose of this study was to evaluate the diagnostic performance of S-Detect when applied to breast ultrasonography (US), and the agreement with an experienced radiologist specializing in breast imaging. From June to August 2015, 192 breast masses in 175 women were included. US features of the breast masses were retrospectively analyzed by a radiologist who specializes in breast imaging and S-Detect, according to the fourth edition of the American College of Radiology Breast Imaging Reporting and Data System lexicon and final assessment categories. Final assessments from S-Detect were in dichotomized form: possibly benign and possibly malignant. Kappa statistics were used to analyze the agreement between the radiologist and S-Detect. Diagnostic performance of the radiologist and S-Detect was calculated, including sensitivity, specificity, positive predictive value (PPV), negative predictive value, accuracy, and area under the receiving operator characteristics curve. Of the 192 breast masses, 72 (37.5%) were malignant, and 120 (62.5%) were benign. Benign masses among category 4a had higher rates of possibly benign assessment on S-Detect for the radiologist, 63.5% to 36.5%, respectively (P=0.797). When the cutoff was set at category 4a, the specificity, PPV, and accuracy was significantly higher in S-Detect compared to the radiologist (all P<0.05), with a higher area under the receiver operator characteristics curve of 0.725 compared to 0.653 (P=0.038). Moderate agreement (k=0.58) was seen in the final assessment between the radiologist and S-Detect. S-Detect may be used as an additional diagnostic tool to improve the specificity of breast US in clinical practice, and guide in decision making for breast masses detected on US

  14. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    International Nuclear Information System (INIS)

    Cavaliere, Carlo; Romeo, Valeria; Aiello, Marco; Mesolella, Massimo; Iorio, Brigida; Barbuto, Luigi; Cantone, Elena; Nicolai, Emanuele; Covello, Mario

    2017-01-01

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K trans , V e , k ep and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  15. Multiparametric evaluation by simultaneous PET-MRI examination in patients with histologically proven laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Cavaliere, Carlo [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Romeo, Valeria, E-mail: valeria.romeo@unina.it [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Aiello, Marco [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy); Mesolella, Massimo; Iorio, Brigida [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Barbuto, Luigi [Department of Advanced Biomedical Sciences, Federico II University, Naples (Italy); Cantone, Elena [Department of Neuroscience, Reproductive and Odontostomatologic Science, ENT Section, Federico II University, Naples (Italy); Nicolai, Emanuele; Covello, Mario [IRCCS SDN, Via E. Gianturco, 113-80143, Naples (Italy)

    2017-03-15

    Highlights: • PET/MRI is feasible and useful for primary staging of laryngeal cancer. • PET/MRI simultaneously provides morphological, metabolic and functional parameters of tumoral laryngeal lesions. • PET/MRI allows an appropriate tumoral staging in terms of lesion extension with significant impact on therapeutic strategies. - Abstract: Objectives: To evaluate the relationship between metabolic 18Fluoro-Deoxyglucose-Positron Emission Tomography (18FDG/PET) and morpho-functional parameters derived by Magnetic Resonance Imaging (MRI) in patients with histologically proven laryngeal cancer. To assess the clinical impact of PET/MRI examination on patient’s staging and treatment planning. Methods: 16 patients with histologically proven laryngeal cancer were enrolled and underwent whole body PET/CT followed by a dedicated PET/MRI of the head/neck region. Data were separately evaluated by two blinded groups: metabolic (SUV and MTV), diffusion (ADC) and perfusion (K{sub trans}, V{sub e}, k{sub ep} and iAUC) maps were obtained by positioning regions of interest (ROIs). Tumoral local extension assessed on PET/MRI was compared to endoscopic findings. Results: A good inter-observer agreement was found in anatomical location and local extension of PET/MRI lesions (Cohen’s kappa 0.9). PET/CT SUV measures highly correlate with ones derived by PET/MRI (e.g., p = 0.96 for measures on VOI). Significant correlations among metabolic, diffusion and perfusion parameters have been detected. PET/MRI had a relevant clinical impact, confirming endoscopic findings (6 cases), helping treatment planning (9 cases), and modifying endoscopic primary staging (1 case). Conclusions: PET/MRI is useful for primary staging of laryngeal cancer, allowing simultaneous collection of metabolic and functional data and conditioning the therapeutic strategies.

  16. New cardiac cameras: single-photon emission CT and PET.

    Science.gov (United States)

    Slomka, Piotr J; Berman, Daniel S; Germano, Guido

    2014-07-01

    Nuclear cardiology instrumentation has evolved significantly in the recent years. Concerns about radiation dose and long acquisition times have propelled developments of dedicated high-efficiency cardiac SPECT scanners. Novel collimator designs, such as multipinhole or locally focusing collimators arranged in geometries that are optimized for cardiac imaging, have been implemented to enhance photon-detection sensitivity. Some of these new SPECT scanners use solid-state photon detectors instead of photomultipliers to improve image quality and to reduce the scanner footprint. These new SPECT devices allow dramatic up to 7-fold reduction in acquisition times or similar reduction in radiation dose. In addition, new hardware for photon attenuation correction allowing ultralow radiation doses has been offered by some vendors. To mitigate photon attenuation artifacts for the new SPECT scanners not equipped with attenuation correction hardware, 2-position (upright-supine or prone-supine) imaging has been proposed. PET hardware developments have been primarily driven by the requirements of oncologic imaging, but cardiac imaging can benefit from improved PET image quality and improved sensitivity of 3D systems. The time-of-flight reconstruction combined with resolution recovery techniques is now implemented by all major PET vendors. These new methods improve image contrast and image resolution and reduce image noise. High-sensitivity 3D PET without interplane septa allows reduced radiation dose for cardiac perfusion imaging. Simultaneous PET/MR hybrid system has been developed. Solid-state PET detectors with avalanche photodiodes or digital silicon photomultipliers have been introduced, and they offer improved imaging characteristics and reduced sensitivity to electromagnetic MR fields. Higher maximum count rate of the new PET detectors allows routine first-pass Rb-82 imaging, with 3D PET acquisition enabling clinical utilization of dynamic imaging with myocardial flow

  17. Positron range in PET imaging: an alternative approach for assessing and correcting the blurring

    DEFF Research Database (Denmark)

    Jødal, Lars; Le Loirec, Cindy; Champion, Christophe

    2012-01-01

    Background: Positron range impairs resolution in PET imaging, especially for high-energy emitters and for small-animal PET. De-blurring in image reconstruction is possible if the blurring distribution is known. Further, the percentage of annihilation events within a given distance from the point...... on allowed-decay isotopes. Methods: It is argued that blurring at the detection level should not be described by positron range r, but instead the 2D-projected distance δ (equal to the closest distance between decay and line-of-response). To determine these 2D distributions, results from a dedicated positron...... is important for improved resolution in PET imaging. Relevant distributions for positron range have been derived for seven isotopes. Distributions for other allowed-decay isotopes may be estimated with the above formulas....

  18. TH-A-18A-01: Innovation in Clinical Breast Imaging

    International Nuclear Information System (INIS)

    Liu, B; Yang, K; Yaffe, M; Chen, J

    2014-01-01

    Several novel modalities have been or are on the verge of being introduced into the breast imaging clinic. These include tomosynthesis imaging, dedicated breast CT, contrast-enhanced digital mammography, and automated breast ultrasound, all of which are covered in this course. Tomosynthesis and dedicated breast CT address the problem of tissue superimposition that limits mammography screening performance, by improved or full resolution of the 3D breast morphology. Contrast-enhanced digital mammography provides functional information that allows for visualization of tumor angiogenesis. 3D breast ultrasound has high sensitivity for tumor detection in dense breasts, but the imaging exam was traditionally performed by radiologists. In automated breast ultrasound, the scan is performed in an automated fashion, making for a more practical imaging tool, that is now used as an adjunct to digital mammography in breast cancer screening. This course will provide medical physicists with an in-depth understanding of the imaging physics of each of these four novel imaging techniques, as well as the rationale and implementation of QC procedures. Further, basic clinical applications and work flow issues will be discussed. Learning Objectives: To be able to describe the underlying physical and physiological principles of each imaging technique, and to understand the corresponding imaging acquisition process. To be able to describe the critical system components and their performance requirements. To understand the rationale and implementation of quality control procedures, as well as regulatory requirements for systems with FDA approval. To learn about clinical applications and understand risks and benefits/strength and weakness of each modality in terms of clinical breast imaging

  19. PET/CT for the staging and follow-up of patients with malignancies

    International Nuclear Information System (INIS)

    Poeppel, T.D.; Krause, B.J.; Heusner, T.A.; Boy, C.; Bockisch, A.; Antoch, G.

    2009-01-01

    Positron emission tomography (PET) and computed tomography (CT) complement each other's strengths in integrated PET/CT. PET is a highly sensitive modality to depict the whole-body distribution of positron-emitting biomarkers indicating tumour metabolic activity. However, conventional PET imaging is lacking detailed anatomical information to precisely localise pathologic findings. CT imaging can readily provide the required morphological data. Thus, integrated PET/CT represents an efficient tool for whole-body staging and functional assessment within one examination. Due to developments in system technology PET/CT devices are continually gaining spatial resolution and imaging speed. Whole-body imaging from the head to the upper thighs is accomplished in less than 20 min. Spatial resolution approaches 2-4 mm. Most PET/CT studies in oncology are performed with 18 F-labelled fluoro-deoxy-D-glucose (FDG). FDG is a glucose analogue that is taken up and trapped within viable cells. An increased glycolytic activity is a characteristic in many types of cancers resulting in avid accumulation of FDG. These tumours excel as 'hot spots' in FDG-PET/CT imaging. FDG-PET/CT proved to be of high diagnostic value in staging and restaging of different malignant diseases, such as colorectal cancer, lung cancer, breast cancer, head and neck cancer, malignant lymphomas, and many more. The standard whole-body coverage simplifies staging and speeds up decision processes to determine appropriate therapeutic strategies. Further development and implementation of new PET-tracers in clinical routine will continually increase the number of PET/CT indications. This promotes PET/CT as the imaging modality of choice for working-up of the most common tumour entities as well as some of the rare malignancies.

  20. Towards real-time topical detection and characterization of FDG dose infiltration prior to PET imaging

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Jason M.; Arlinghaus, Lori R. [Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN (United States); Rani, Sudheer D. [Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN (United States); Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Shone, Martha D. [Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Abramson, Vandana G. [Vanderbilt University Medical Center, Department of Medicine, Nashville, TN (United States); Vanderbilt-Ingram Cancer Center, Nashville, TN (United States); Pendyala, Praveen [Vanderbilt University Medical Center, Department of Radiation Oncology, Nashville, TN (United States); Chakravarthy, A.B. [Vanderbilt-Ingram Cancer Center, Nashville, TN (United States); Vanderbilt University Medical Center, Department of Radiation Oncology, Nashville, TN (United States); Gorge, William J.; Knowland, Joshua G.; Lattanze, Ronald K.; Perrin, Steven R. [Lucerno Dynamics, LLC, Morrisville, NC (United States); Scarantino, Charles W. [Lucerno Dynamics, LLC, Morrisville, NC (United States); University of North Carolina, Department of Radiation Oncology, Chapel Hill, NC (United States); Townsend, David W. [Lucerno Dynamics, LLC, Morrisville, NC (United States); Technology and Research-National University of Singapore, Clinical Imaging Research Centre, Agency for Science, Singapore (Singapore); Abramson, Richard G. [Vanderbilt University Institute of Imaging Science, Vanderbilt University Medical Center, Nashville, TN (United States); Vanderbilt University Medical Center, Department of Radiology and Radiological Sciences, Nashville, TN (United States); Vanderbilt-Ingram Cancer Center, Nashville, TN (United States); Yankeelov, Thomas E. [The University of Texas at Austin, Institute for Computational and Engineering Sciences, and Departments of Biomedical Engineering and Internal Medicine, Austin, TX (United States)

    2016-12-15

    To dynamically detect and characterize {sup 18}F-fluorodeoxyglucose (FDG) dose infiltrations and evaluate their effects on positron emission tomography (PET) standardized uptake values (SUV) at the injection site and in control tissue. Investigational gamma scintillation sensors were topically applied to patients with locally advanced breast cancer scheduled to undergo limited whole-body FDG-PET as part of an ongoing clinical study. Relative to the affected breast, sensors were placed on the contralateral injection arm and ipsilateral control arm during the resting uptake phase prior to each patient's PET scan. Time-activity curves (TACs) from the sensors were integrated at varying intervals (0-10, 0-20, 0-30, 0-40, and 30-40 min) post-FDG and the resulting areas under the curve (AUCs) were compared to SUVs obtained from PET. In cases of infiltration, observed in three sensor recordings (30 %), the injection arm TAC shape varied depending on the extent and severity of infiltration. In two of these cases, TAC characteristics suggested the infiltration was partially resolving prior to image acquisition, although it was still apparent on subsequent PET. Areas under the TAC 0-10 and 0-20 min post-FDG were significantly different in infiltrated versus non-infiltrated cases (Mann-Whitney, p < 0.05). When normalized to control, all TAC integration intervals from the injection arm were significantly correlated with SUV{sub peak} and SUV{sub max} measured over the infiltration site (Spearman ρ ≥ 0.77, p < 0.05). Receiver operating characteristic (ROC) analyses, testing the ability of the first 10 min of post-FDG sensor data to predict infiltration visibility on the ensuing PET, yielded an area under the ROC curve of 0.92. Topical sensors applied near the injection site provide dynamic information from the time of FDG administration through the uptake period and may be useful in detecting infiltrations regardless of PET image field of view. This dynamic information

  1. Towards real-time topical detection and characterization of FDG dose infiltration prior to PET imaging

    International Nuclear Information System (INIS)

    Williams, Jason M.; Arlinghaus, Lori R.; Rani, Sudheer D.; Shone, Martha D.; Abramson, Vandana G.; Pendyala, Praveen; Chakravarthy, A.B.; Gorge, William J.; Knowland, Joshua G.; Lattanze, Ronald K.; Perrin, Steven R.; Scarantino, Charles W.; Townsend, David W.; Abramson, Richard G.; Yankeelov, Thomas E.

    2016-01-01

    To dynamically detect and characterize "1"8F-fluorodeoxyglucose (FDG) dose infiltrations and evaluate their effects on positron emission tomography (PET) standardized uptake values (SUV) at the injection site and in control tissue. Investigational gamma scintillation sensors were topically applied to patients with locally advanced breast cancer scheduled to undergo limited whole-body FDG-PET as part of an ongoing clinical study. Relative to the affected breast, sensors were placed on the contralateral injection arm and ipsilateral control arm during the resting uptake phase prior to each patient's PET scan. Time-activity curves (TACs) from the sensors were integrated at varying intervals (0-10, 0-20, 0-30, 0-40, and 30-40 min) post-FDG and the resulting areas under the curve (AUCs) were compared to SUVs obtained from PET. In cases of infiltration, observed in three sensor recordings (30 %), the injection arm TAC shape varied depending on the extent and severity of infiltration. In two of these cases, TAC characteristics suggested the infiltration was partially resolving prior to image acquisition, although it was still apparent on subsequent PET. Areas under the TAC 0-10 and 0-20 min post-FDG were significantly different in infiltrated versus non-infiltrated cases (Mann-Whitney, p < 0.05). When normalized to control, all TAC integration intervals from the injection arm were significantly correlated with SUV_p_e_a_k and SUV_m_a_x measured over the infiltration site (Spearman ρ ≥ 0.77, p < 0.05). Receiver operating characteristic (ROC) analyses, testing the ability of the first 10 min of post-FDG sensor data to predict infiltration visibility on the ensuing PET, yielded an area under the ROC curve of 0.92. Topical sensors applied near the injection site provide dynamic information from the time of FDG administration through the uptake period and may be useful in detecting infiltrations regardless of PET image field of view. This dynamic information may also

  2. PET - CT, Diagnostic Priorities in Oncology

    International Nuclear Information System (INIS)

    Codorean, I.; Bugeag, G.

    2006-01-01

    Full text: Cancer is one of the leading cause of death worldwide. Efficient therapy depends mainly on early detection of morbiduous process. It is known that cancer is starting at molecular level by a change of a gene which controls cell growth and behaviour, particularly by increased DNA synthesis and glucose local use as energetic background of anarchic cell multiplication. It has been proven that it takes a long period to time of 4-5 years to the moment when alterations of cell molecular structures have to expand to tissues and organs; for this reason, when detected by present available in our country diagnosis methods, including sectional techniques CT and MRI, cancer may not be cured. Surgical treatment, chemotherapy and radiotherapy may assure, in correlation with staging, a survival of no more than 4-5 years. The purpose of medical activity is early detection of cancer, before dissemination in other organs, to institute early, efficient therapy. Do we have such a detection technique? The answer is YES; its name is Fusion-Imaging PET-CT, largely introduced worldwide in clinical practice in last 5 years. Our presentation will show PET imaging principles; technologic bases of integrated PET-CT scanners, used positron radiotracers, protocol and clinic applications. We will present CT, PET and fusion images in detection and establishment of malignant substratum of solitary pulmonary nodules and other cancer types, post therapeutic staging and re-staging in lymphomas, breast cancer, uterine cervical cancer, gastric cancer and prostate cancer. (author)

  3. Detection of prostate cancer by an FDG-PET cancer screening program: results from a Japanese nationwide survey

    International Nuclear Information System (INIS)

    Minamimoto, Ryogo; Senda, Michio; Jinnouchi, Seishi; Terauchi, Takashi; Inoue, Tomio

    2014-01-01

    The aim of this study was to analyze detection rates and effectiveness of 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET) cancer screening program for prostate cancer in Japan, which is defined as a cancer-screening program for subjects without known cancer. It contains FDG-PET aimed at detection of cancer at an early stage with or without additional screening tests such as prostate-specific antigen (PSA) and magnetic resonance imaging (MRI). A total of 92,255 asymptomatic men underwent the FDG-PET cancer screening program. Of these, 504 cases with findings of possible prostate cancer in any screening method were analyzed. Of the 504 cases, 165 were verified as having prostate cancer. Of these, only 61 cases were detected by FDG-PET, which result in 37.0% relative sensitivity and 32.8% positive predictive value (PPV). The sensitivity of PET/computed tomography (CT) scanner was higher than that of dedicated PET (44.0% vs. 20.4%). However, the sensitivity of FDG-PET was lower than that of PSA and pelvic MRI. FDG-PET did not contribute to improving the sensitivity and PPV when performed as combined screening. PSA should be included in FDG-PET cancer screening programs to screen for prostate cancer

  4. Glycolytic activity in breast cancer using 18F-FDG PET/CT as prognostic predictor: A molecular phenotype approach.

    Science.gov (United States)

    Garcia Vicente, A M; Soriano Castrejón, A; Amo-Salas, M; Lopez Fidalgo, J F; Muñoz Sanchez, M M; Alvarez Cabellos, R; Espinosa Aunion, R; Muñoz Madero, V

    2016-01-01

    To explore the relationship between basal (18)F-FDG uptake in breast tumors and survival in patients with breast cancer (BC) using a molecular phenotype approach. This prospective and multicentre study included 193 women diagnosed with BC. All patients underwent an (18)F-FDG PET/CT prior to treatment. Maximum standardized uptake value (SUVmax) in tumor (T), lymph nodes (N), and the N/T index was obtained in all the cases. Metabolic stage was established. As regards biological prognostic parameters, tumors were classified into molecular sub-types and risk categories. Overall survival (OS) and disease free survival (DFS) were obtained. An analysis was performed on the relationship between semi-quantitative metabolic parameters with molecular phenotypes and risk categories. The effect of molecular sub-type and risk categories in prognosis was analyzed using Kaplan-Meier and univariate and multivariate tests. Statistical differences were found in both SUVT and SUVN, according to the molecular sub-types and risk classifications, with higher semi-quantitative values in more biologically aggressive tumors. No statistical differences were observed with respect to the N/T index. Kaplan-Meier analysis revealed that risk categories were significantly related to DFS and OS. In the multivariate analysis, metabolic stage and risk phenotype showed a significant association with DFS. High-risk phenotype category showed a worst prognosis with respect to the other categories with higher SUVmax in primary tumor and lymph nodes. Copyright © 2015 Elsevier España, S.L.U. and SEMNIM. All rights reserved.

  5. Hospice Admission and Survival After 18F-Fluoride PET Performed for Evaluation of Osseous Metastatic Disease in the National Oncologic PET Registry.

    Science.gov (United States)

    Gareen, Ilana F; Hillner, Bruce E; Hanna, Lucy; Makineni, Rajesh; Duan, Fenghai; Shields, Anthony F; Subramaniam, Rathan M; Siegel, Barry A

    2018-03-01

    We have previously reported that PET using 18 F-fluoride (NaF PET) for assessment of osseous metastatic disease was associated with substantial changes in intended management in Medicare beneficiaries participating in the National Oncologic PET Registry (NOPR). Here, we use Medicare administrative data to examine the association between NaF PET results and hospice claims within 180 d and 1-y survival. Methods: We classified NOPR NaF PET results linked to Medicare claims by imaging indication (initial staging [IS]; detection of suspected first osseous metastasis [FOM]; suspected progression of osseous metastasis [POM]; or treatment monitoring [TM]) and type of cancer (prostate, lung, breast, or other). Results were classified as definitely positive scan findings versus probably positive scan findings versus negative scan findings for osseous metastasis for IS and FOM; more extensive disease versus no change or less extensive disease for POM; and worse prognosis versus no change or better prognosis for TM, based on the postscan assessment. Our study included 21,167 scans obtained from 2011 to 2014 of consenting NOPR participants aged 65 y or older. Results: The relative risk of hospice claims within 180 d of a NaF PET scan was 2.0-7.5 times higher for patients with evidence of new or progressing osseous metastasis than for those without, depending on indication and cancer type (all P PET scan results are highly associated with subsequent hospice claims and, ultimately, with patient survival. NaF PET provides important information on the presence of osseous metastasis and prognosis to assist patients and their physicians when making decisions on whether to select palliative care and transition to hospice or whether to continue treatment. © 2018 by the Society of Nuclear Medicine and Molecular Imaging.

  6. Value of PET/CT 3D visualization of head and neck squamous cell carcinoma extended to mandible.

    Science.gov (United States)

    Lopez, R; Gantet, P; Julian, A; Hitzel, A; Herbault-Barres, B; Alshehri, S; Payoux, P

    2018-05-01

    To study an original 3D visualization of head and neck squamous cell carcinoma extending to the mandible by using [18F]-NaF PET/CT and [18F]-FDG PET/CT imaging along with a new innovative FDG and NaF image analysis using dedicated software. The main interest of the 3D evaluation is to have a better visualization of bone extension in such cancers and that could also avoid unsatisfying surgical treatment later on. A prospective study was carried out from November 2016 to September 2017. Twenty patients with head and neck squamous cell carcinoma extending to the mandible (stage 4 in the UICC classification) underwent [18F]-NaF and [18F]-FDG PET/CT. We compared the delineation of 3D quantification obtained with [18F]-NaF and [18F]-FDG PET/CT. In order to carry out this comparison, a method of visualisation and quantification of PET images was developed. This new approach was based on a process of quantification of radioactive activity within the mandibular bone that objectively defined the significant limits of this activity on PET images and on a 3D visualization. Furthermore, the spatial limits obtained by analysis of the PET/CT 3D images were compared to those obtained by histopathological examination of mandibular resection which confirmed intraosseous extension to the mandible. The [18F]-NaF PET/CT imaging confirmed the mandibular extension in 85% of cases and was not shown in [18F]-FDG PET/CT imaging. The [18F]-NaF PET/CT was significantly more accurate than [18F]-FDG PET/CT in 3D assessment of intraosseous extension of head and neck squamous cell carcinoma. This new 3D information shows the importance in the imaging approach of cancers. All cases of mandibular extension suspected on [18F]-NaF PET/CT imaging were confirmed based on histopathological results as a reference. The [18F]-NaF PET/CT 3D visualization should be included in the pre-treatment workups of head and neck cancers. With the use of a dedicated software which enables objective delineation of

  7. Thoracic cavity definition for 3D PET/CT analysis and visualization.

    Science.gov (United States)

    Cheirsilp, Ronnarit; Bascom, Rebecca; Allen, Thomas W; Higgins, William E

    2015-07-01

    X-ray computed tomography (CT) and positron emission tomography (PET) serve as the standard imaging modalities for lung-cancer management. CT gives anatomical details on diagnostic regions of interest (ROIs), while PET gives highly specific functional information. During the lung-cancer management process, a patient receives a co-registered whole-body PET/CT scan pair and a dedicated high-resolution chest CT scan. With these data, multimodal PET/CT ROI information can be gleaned to facilitate disease management. Effective image segmentation of the thoracic cavity, however, is needed to focus attention on the central chest. We present an automatic method for thoracic cavity segmentation from 3D CT scans. We then demonstrate how the method facilitates 3D ROI localization and visualization in patient multimodal imaging studies. Our segmentation method draws upon digital topological and morphological operations, active-contour analysis, and key organ landmarks. Using a large patient database, the method showed high agreement to ground-truth regions, with a mean coverage=99.2% and leakage=0.52%. Furthermore, it enabled extremely fast computation. For PET/CT lesion analysis, the segmentation method reduced ROI search space by 97.7% for a whole-body scan, or nearly 3 times greater than that achieved by a lung mask. Despite this reduction, we achieved 100% true-positive ROI detection, while also reducing the false-positive (FP) detection rate by >5 times over that achieved with a lung mask. Finally, the method greatly improved PET/CT visualization by eliminating false PET-avid obscurations arising from the heart, bones, and liver. In particular, PET MIP views and fused PET/CT renderings depicted unprecedented clarity of the lesions and neighboring anatomical structures truly relevant to lung-cancer assessment. Copyright © 2015 Elsevier Ltd. All rights reserved.

  8. Cowden syndrome detected by FDG PET/CT in an endometrial cancer patient

    International Nuclear Information System (INIS)

    Kang, Yun Hee; Lee, Hye Kyung; Park, Geon

    2016-01-01

    Cowden syndrome (CS) is a rare autosomal dominant disorder characterized by multiple hamartomas in various tissues and cancers (breast, thyroid, and endometrium). We report CS of the esophagus and gastrointestinal tract that was incidentally detected by positron emission tomography/computed tomography (PET/CT) at postoperative surveillance in an endometrial cancer patient. PET/CT showed mildly increased FDG uptake along the entire esophagus and stomach. Upper GI endoscopy and histologic examination revealed glycogenic acanthosis of the esophagus and several hundred gastric polyps. In our case, increased FDG uptake of the esophageal wall contributed to the diagnosis of CS

  9. Cowden syndrome detected by FDG PET/CT in an endometrial cancer patient

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Yun Hee; Lee, Hye Kyung [Eulji University Hospital, Daejeon (Korea, Republic of); Park, Geon [Dept. of Radiology, The Catholic University of Korea, Daejeon Saint Mary' s Hospital, Daejeon (Korea, Republic of)

    2016-09-15

    Cowden syndrome (CS) is a rare autosomal dominant disorder characterized by multiple hamartomas in various tissues and cancers (breast, thyroid, and endometrium). We report CS of the esophagus and gastrointestinal tract that was incidentally detected by positron emission tomography/computed tomography (PET/CT) at postoperative surveillance in an endometrial cancer patient. PET/CT showed mildly increased FDG uptake along the entire esophagus and stomach. Upper GI endoscopy and histologic examination revealed glycogenic acanthosis of the esophagus and several hundred gastric polyps. In our case, increased FDG uptake of the esophageal wall contributed to the diagnosis of CS.

  10. FDG PET in the diagnosis of giant cell arteritis

    International Nuclear Information System (INIS)

    Turlakow, A.; Yeung, H.W.D.; Pui, J.; Macapinlac, H.; Liebovitz, E.; Rusch, V.; Goy, A.; Larson, S.M.

    2003-01-01

    Full text: To evaluate the role of PET in the diagnosis of vasculitis. Methods: We report a case of giant cell arteritis diagnosed by FDG-PET in a 75-year-old woman with a fever of unknown origin. The patient presented with a 3 month history of fatigue, fevers, headaches, visual disturbance and jaw claudication. Diagnosis of temporal arteritis was initially excluded because of a normal ESR. CT scan showed an anterior mediastinal mass, suspicious for malignancy. An FDG-PET scan for pre-operative evaluation was acquired 45 minutes after intravenous injection of 10 mCi F18-FDG, on a dedicated PET scanner. Image reconstruction was performed using an iterative algorithm with segmented attenuation correction. The study identified striking localisation of FDG to the entire aorta, left main coronary artery, and subclavian, carotid and common iliac arteries bilaterally (SUV max range 4-4.5 g/ml), suggestive of large vessel arteritis. Subsequent excisional biopsy of the mediastinal mass confirmed giant cell vasculitis of a large muscular artery in thymic tissue. No malignancy was detected. A repeat ESR was 129 mm/hr. The patient was commenced on oral Prednisone, with prompt improvement of symptoms, ESR and anaemia and complete normalisation of the FDG-PET scan within two weeks. This case suggests a potential role of FDG-PET in the non-invasive diagnosis, classification and follow-up of giant cell arteritis, and possibly other vasculitides, so far notoriously difficult to diagnose, relying usually on a constellation of non-specific symptoms, laboratory investigations or invasive pathologic and angiographic means. Copyright (2003) The Australian and New Zealand Society of Nuclear Medicine Inc

  11. First PET scans in Estonia

    International Nuclear Information System (INIS)

    Nazarenko, Sergei

    2003-01-01

    First PET scans in Estonia were performed on 25th November 2002 in North Estonia Regional Hospital, Tallinn. Six patients with melanoma underwent scanning with FDG. This event was a result of thorough extensive preparations first started in 2000 during the European Association of Nuclear Medicine congress in Paris. During the congress first contacts were made with providers of mobile PET units. At the same time negotiations were begun with potential FDG suppliers. For the introduction of PET in Estonia mobile truckmounted scanning technology was chosen due to low level of initial investments. Of particular importance was also availability of maintenance personnel from the device providers. A significant prerequisite was potential availability of FDG from the neighbourhood - Finland and Sweden. The latter avoided the necessity for investments into local cyclotrons and local FDG production. For the first scanning experience the dedicated truckmounted PET-camera Accel, Siemens was brought by the International Hospital Group (IHG, Amersfoort, Netherlands). The device arrived by ferry from Stockholm to Tallinn harbour at 10 o'clock in the morning and left by ferry for Helsinki at 23 o'clock. The team-on-truck consisted of one technician for device operation, two drivers and two company representatives. North Estonia Regional Hospital provided three additional technicians for patient preparation and FDG injection, one nuclear medicine doctor and one specialist of biomedical engineering and medical physics. The FDG was provided by MAP Medical Technologies, Schering, Helsinki, Finland. The shipments were made by air. This was possible due to small distance between Tallinn and Helsinki of approximately 80 km due to the regular flight connections between the two cities. The FDG was shipped in two lots with a time interval of 4 hours. The patient selection was based on clinical and histopathology data. In all six patients the exam was justified for detailied staging and

  12. Detection of distant metastases in patients with locally advanced breast cancer: role of {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography and conventional imaging with computed tomography scans

    Energy Technology Data Exchange (ETDEWEB)

    Bitencourt, Almir Galvao Vieira; Andrade, Wesley Pereira; Cunha, Rodrigo Rodrigues da; Conrado, Jorge Luis Fonseca de Acioli; Lima, Eduardo Nobrega Pereira; Barbosa, Paula Nicole Vieira Pinto; Chojniak, Rubens, E-mail: rodrigo.rcunha@hotmail.com [A. C. Camargo Cancer Center, Sao Paulo, SP (Brazil); Hospital Beneficincia Portuguesa de Sao Paulo, Sao Paulo, SP (Brazil)

    2017-07-15

    Objective: To evaluate positron emission tomography/computed tomography (PET/CT) and conventional imaging tests for the detection of distant metastases in patients with locally advanced breast cancer. Materials and Methods: We included 81 patients with breast cancer who had undergone {sup 18}-fluorodeoxyglucose (FDG) PET/CT before treatment. Conventional imaging included the following: bone scintigraphy; chest X-ray (in 14.5%) or CT (in 85.5%); and abdominal ultrasound (in 10.8%), CT (in 87.8%), or magnetic resonance imaging (in 1.4%). Histopathology and clinical/imaging follow-up served as reference. Results: Distant metastases were observed in nine patients (11.1%). On patient-based analysis, conventional imaging identified distant metastases in all 9 patients. In one patient, the initial {sup 18}F-FDG PET/CT failed to demonstrate bone metastases that was evident on bone scintigraphy. In two patients, the CT scan failed to show extra-axillary lymph node metastases that were identified on {sup 18}F-FDG PET/CT. There was no significant difference between {sup 18}F-FDG PET/CT and conventional imaging in terms of their sensitivity for the detection of distant metastases in patients with locally advanced breast cancer. Conclusion: This study showed that {sup 18}F-FDG PET/CT and conventional imaging with CT scans had similar sensitivity for the diagnosis of distant metastases in patients with locally advanced breast cancer. {sup 18}F-FDG PET/CT can add information about extra-axillary lymph node involvements. (author)

  13. Predicting neo-adjuvant chemotherapy response and progression-free survival of locally advanced breast cancer using textural features of intratumoral heterogeneity on F-18 FDG PET/CT and diffusion-weighted MR imaging.

    Science.gov (United States)

    Yoon, Hai-Jeon; Kim, Yemi; Chung, Jin; Kim, Bom Sahn

    2018-03-30

    Predicting response to neo-adjuvant chemotherapy (NAC) and survival in locally advanced breast cancer (LABC) is important. This study investigated the prognostic value of tumor heterogeneity evaluated with textural analysis through F-18 fluorodeoxyglucose (FDG) positron emission tomography (PET) and diffusion-weighted imaging (DWI). We enrolled 83 patients with LABC who had completed NAC and curative surgery. Tumor texture indices from pretreatment FDG PET and DWI were extracted from histogram analysis and 7 different parent matrices: co-occurrence matrix, the voxel-alignment matrix, neighborhood intensity difference matrix, intensity size-zone matrix (ISZM), normalized gray-level co-occurrence matrix (NGLCM), neighboring gray-level dependence matrix (NGLDM), and texture spectrum matrix. The predictive values of textural features were tested regarding both pathologic NAC response and progression-free survival. Among 83 patients, 46 were pathologic responders, while 37 were nonresponders. The PET texture indices from 7 parent matrices, DWI texture indices from histogram, and 1 parent matrix (NGLCM) showed significant differences according to NAC response. On multivariable analysis, number nonuniformity of PET extracted from the NGLDM was an independent predictor of pathologic response (P = .009). During a median follow-up period of 17.3 months, 14 patients experienced recurrence. High-intensity zone emphasis (HIZE) and high-intensity short-zone emphasis (HISZE) from PET extracted from ISZM were significant textural predictors (P = .011 and P = .033). On Cox regression analysis, only HIZE was a significant predictor of recurrence (P = .027), while HISZE showed borderline significance (P = .107). Tumor texture indices are useful for NAC response prediction in LABC. Moreover, PET texture indices can help to predict disease recurrence. © 2018 Wiley Periodicals, Inc.

  14. FDG PET/CT features of ovarian metastasis

    International Nuclear Information System (INIS)

    Kitajima, K.; Suzuki, K.; Senda, M.; Kita, M.; Onishi, Y.; Maeda, T.; Yoshikawa, T.; Ohno, Y.; Sugimura, K.

    2011-01-01

    Aim: To assess the characteristics of [ 18 F]-fluoro-2-deoxy-D-glucose (FDG) uptake in cases of ovarian metastasis using positron-emission tomography/computed tomography (PET/CT). Materials and methods: Twelve patients with 16 ovarian metastases arising from colon cancer (n = 6), breast cancer (n = 4), gastric cancer (n = 3), and pancreatic cancer (n = 3) who underwent FDG-PET/CT examination were included in this study. The effect of lesion size and morphological pattern (predominantly solid or cystic) on FDG uptake was evaluated using the quantitative standardized uptake value (SUV). Results: The mean maximum SUV for the 16 lesions was 4.6 ± 2.4 (range 1.8 ∼ 9.9). The Pearson correlation coefficient test showed no significant correlation between maximum SUV and lesion size (r = 0.21, p = 0.42). The maximum SUV of solid (n = 5) and cystic (n = 11) lesions was 5.5 ± 2.7 and 4.3 ± 2.2, respectively, and the difference was not significant (p = 0.43). Breast cancer showed the highest maximum SUV (6.4 ± 3.6), followed by colon cancer (5.3 ± 1.4), gastric cancer (3.3 ± 0.5), and pancreatic cancer (2.2 ± 0.6). Conclusion: Ovarian metastases show a variable maximum SUV with mild to intense FDG uptake.

  15. Imaging and PET - PET/CT imaging

    International Nuclear Information System (INIS)

    Von Schulthess, G.K.; Hany, Th.F.

    2008-01-01

    PET/CT has grown because the lack of anatomic landmarks in PET makes 'hardware-fusion' to anatomic cross-sectional data extremely useful. Addition of CT to PET improves specificity, but also sensitivity, and adding PET to CT adds sensitivity and specificity in tumor imaging. The synergistic advantage of adding CT is that the attenuation correction needed for PET data can also be derived from the CT data. This makes PET-CT 25-30% faster than PET alone, leading to higher patient throughput and a more comfortable examination for patients typically lasting 20 minutes or less. FDG-PET-CT appears to provide relevant information in the staging and therapy monitoring of many tumors, such as lung carcinoma, colorectal cancer, lymphoma, gynaecological cancers, melanoma and many others, with the notable exception of prostatic cancer. for this cancer, choline derivatives may possibly become useful radiopharmaceuticals. The published literature on the applications of FDG-PET-CT in oncology is still limited but several designed studies have demonstrated the benefits of PET-CT. (authors)

  16. Evaluation of PET Scanner Performance in PET/MR and PET/CT Systems: NEMA Tests.

    Science.gov (United States)

    Demir, Mustafa; Toklu, Türkay; Abuqbeitah, Mohammad; Çetin, Hüseyin; Sezgin, H Sezer; Yeyin, Nami; Sönmezoğlu, Kerim

    2018-02-01

    The aim of the present study was to compare the performance of positron emission tomography (PET) component of PET/computed tomography (CT) with new emerging PET/magnetic resonance (MR) of the same vendor. According to National Electrical Manufacturers Association NU2-07, five separate experimental tests were performed to evaluate the performance of PET scanner of General Electric GE company; SIGNATM model PET/MR and GE Discovery 710 model PET/CT. The main investigated aspects were spatial resolution, sensitivity, scatter fraction, count rate performance, image quality, count loss and random events correction accuracy. The findings of this study demonstrated superior sensitivity (~ 4 folds) of PET scanner in PET/MR compared to PET/CT system. Image quality test exhibited higher contrast in PET/MR (~ 9%) compared with PET/CT. The scatter fraction of PET/MR was 43.4% at noise equivalent count rate (NECR) peak of 218 kcps and the corresponding activity concentration was 17.7 kBq/cc. Whereas the scatter fraction of PET/CT was found as 39.2% at NECR peak of 72 kcps and activity concentration of 24.3 kBq/cc. The percentage error of the random event correction accuracy was 3.4% and 3.1% in PET/MR and PET/CT, respectively. It was concluded that PET/MR system is about 4 times more sensitive than PET/CT, and the contrast of hot lesions in PET/MR was ~ 9% higher than PET/CT. These outcomes also emphasize the possibility to achieve excellent clinical PET images with low administered dose and/or a short acquisition time in PET/MR.

  17. The role of the US Army Veterinary Corps in military family pet health.

    Science.gov (United States)

    Vincent-Johnson, Nancy A

    2013-01-01

    Even though privately-owned pet care is a lower priority mission than military working dog care, food inspection,and the public health mission, it is still very important,and the one that many Veterinary Corps officers, civil-ian veterinarians, and technicians enjoy the most. The vast majority of veterinarians and technicians went into veterinary medicine because of a love for animals. It is fulfilling to offer guidance to a client with a new puppy or kitten, see a sick pet improve after treatment, and interact with dozens of animals and clients in a day. The services provided by the Army Veterinary Corps in car-ing for pets has expanded over the years and the standard of care has improved as well. It is truly a privilege to serve those who dedicate themselves to the protection of our Nation. The Army Veterinary Corps is indeed proud to provide care to the pets of Warfighters of the Army,Navy, Marine Corps, Air Force, and Coast Guard; their family members; and our military retirees.

  18. Detection of internal mammary lymph node metastasis with {sup 18}F-fluorodeoxyglucose positron emission tomography/computed tomography in patients with stage III breast cancer

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Min Jung; Lee, Jong Jin; Kim, Hye Ok; Chae, Sun-Young; Ryu, Jin-Sook; Moon, Dae Hyuk [University of Ulsan College of Medicine, Asan Medical Center, Department of Nuclear Medicine, Songpa-gu, Seoul (Korea, Republic of); Park, Seol Hoon [Ulsan University Hospital, Department of Nuclear Medicine, Ulsan (Korea, Republic of); Ahn, Sei Hyun; Lee, Jong Won; Son, Byung Ho [University of Ulsan College of Medicine, Asan Medical Center, Department of Surgery, Seoul (Korea, Republic of); Gong, Gyung-Yub [University of Ulsan College of Medicine, Asan Medical Center, Department of Pathology, Seoul (Korea, Republic of)

    2014-03-15

    The present study assessed the positive predictive value (PPV) of {sup 18}F-fluorodeoxyglucose (FDG) positron emission tomography/computed tomography (PET/CT) for the detection of internal mammary node (IMN) metastasis in patients with clinical stage III breast cancer. Patients who were diagnosed with clinical stage III breast cancer and underwent pretreatment {sup 18}F-FDG PET/CT were retrospectively analyzed. The {sup 18}F-FDG PET/CT scans were prospectively reviewed by two board-certified nuclear medicine physicians in a blinded manner. The intensities of IMNs were graded into four categories (no activity and lower, similar, and higher activities than that of the mediastinal blood pool). IMNs were measured from the combined CT (largest diameter of the short axis). Histologic data of the IMNs were obtained by ultrasonography-guided fine-needle aspiration biopsy or surgical excision. The PPV was calculated for pathologically confirmed IMNs. Visual grade, maximum standardized uptake values (SUV{sub max}), and sizes were analyzed according to the pathology results. There were 249 clinical stage III breast cancer patients (age 48.0 ± 10.1 years, range 26-79 years) who had undergone initial {sup 18}F-FDG PET/CT prior to treatment. Excluding 33 cases of stage IV breast cancer, 62 of 216 patients had visible IMNs on {sup 18}F-FDG PET/CT, and histologic confirmation was obtained in 31 patients. There were 27 metastatic and four nonmetastatic nodes (PPV 87.1 %). Metastatic nodes mostly presented with visual grade 3 (83.9 %), and SUV{sub max} and size were 3.5 ± 4.3 and 5.6 ± 2.0 mm, respectively. {sup 18}F-FDG PET/CT has a high PPV for IMN metastasis in clinical stage III breast cancer, indicating the possibility of metastasis in IMNs with FDG uptake similar to/lower than that of the blood pool or small-sized nodes. (orig.)

  19. Design, Implementation, and Characterization of a Dedicated Breast Computed Mammotomography System for Enhanced Lesion Imaging

    National Research Council Canada - National Science Library

    McKinley, Randolph L

    2006-01-01

    .... Half cone-beam orbits have been implemented and investigated and have indicated they are feasible for a wide range of breast sizes. Future studies will focus on characterizing the system in terms of dose efficiency, contrast sensitivity, and evaluation for a range of breast sizes and compositions. Patient bed optimization will also be investigated.

  20. Uterine cervical melanoma presenting with rapid progression detected by PET/CT

    International Nuclear Information System (INIS)

    Tsai, Ya-Ju; Shueng, Pei-Wei; Chan, Sheng-Chien; Chuang, Wen-Yu; Shiau, Yu-Chien; Hsu, Chung-Huei

    2012-01-01

    Malignant melanoma of the uterine cervix is a rare extracutaneous melanoma which develops aggressively and is associated with a bleak prognosis. To our knowledge, no prior published reports have discussed the role of 18F-FDG positron emission tomography/computed tomography (PET/CT) in managing this disease. Our case study involved a 66-year-old woman with a malignant melanoma of the uterine cervix. The patient received PET/CT that identified metastases and lesions which had not been detected from her MRI. Serial PET/CT elucidated that the disease was initially limited to the pelvis, but then metastasized to the abdominal para-aortic lymph nodes, followed by extensive metastases to the brain, lungs, breast, supraclavicular, neck, and other abdominal lymph nodes, as observed at 6-month follow-up. PET/CT was used to complement conventional anatomic imaging modalities, and provided a novel modality for whole body screening. Visualization of the metabolic activity of indeterminate lesions may help in staging, re-staging, treatment planning, and prognostic prediction for patients with this rare disease

  1. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    International Nuclear Information System (INIS)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun

    2012-01-01

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  2. Occult Invasive Lobular Carcinoma of Breast Detected by Stomach Metastasis: A Case Report

    Energy Technology Data Exchange (ETDEWEB)

    KIm, So Jung; Jung, Hae Kyoung; Ko, Kyung Hee; Yoon, Jung Hyun [Dept. of Radiology, Bundang CHA general Hospital, CHA University College of Medicine, Seongnam (Korea, Republic of)

    2012-02-15

    Gastric metastasis from primary breast cancer is a rare phenomenon that is more prevalent in the invasive lobular type of breast cancer. We describe a very rare case of occult invasive lobular cancer of the breast detected by the initial presentation of gastric metastasis in a patient without a history of breast cancer. A 18F-fluorodeoxyglucose positron-emission tomography/computed tomography (FDG PET/CT) which showed increased FDG uptake in the stomach, abdominal mesentery and the right breast, and played pivotal roles in the detection of occult primary breast cancer and a diagnosis of gastric metastasis as an ancillary method for obtaining histological results and immunohistochemical stains.

  3. Association between partial-volume corrected SUVmax and Oncotype DX recurrence score in early-stage, ER-positive/HER2-negative invasive breast cancer.

    Science.gov (United States)

    Lee, Su Hyun; Ha, Seunggyun; An, Hyun Joon; Lee, Jae Sung; Han, Wonshik; Im, Seock-Ah; Ryu, Han Suk; Kim, Won Hwa; Chang, Jung Min; Cho, Nariya; Moon, Woo Kyung; Cheon, Gi Jeong

    2016-08-01

    Oncotype DX, a 21-gene expression assay, provides a recurrence score (RS) which predicts prognosis and the benefit from adjuvant chemotherapy in patients with early-stage, estrogen receptor-positive (ER-positive), and human epidermal growth factor receptor 2-negative (HER2-negative) invasive breast cancer. However, Oncotype DX tests are expensive and not readily available in all institutions. The purpose of this study was to investigate whether metabolic parameters on (18)F-FDG PET/CT are associated with the Oncotype DX RS and whether (18)F-FDG PET/CT can be used to predict the Oncotype DX RS. The study group comprised 38 women with stage I/II, ER-positive/HER2-negative invasive breast cancer who underwent pretreatment (18)F-FDG PET/CT and Oncotype DX testing. On PET/CT, maximum (SUVmax) and average standardized uptake values, metabolic tumor volume, and total lesion glycolysis were measured. Partial volume-corrected SUVmax (PVC-SUVmax) determined using the recovery coefficient method was also evaluated. Oncotype DX RS (0 - 100) was categorized as low (negative breast cancer.

  4. Textural features of 18F-FDG PET after two cycles of neoadjuvant chemotherapy can predict pCR in patients with locally advanced breast cancer.

    Science.gov (United States)

    Cheng, Lin; Zhang, Jianping; Wang, Yujie; Xu, Xiaoli; Zhang, Yongping; Zhang, Yingjian; Liu, Guangyu; Cheng, Jingyi

    2017-08-01

    This study was designed to evaluate the utility of textural features for predicting pathological complete response (pCR) to neoadjuvant chemotherapy (NAC). Sixty-one consecutive patients with locally advanced breast cancer underwent 18 F-FDG PET/CT scanning at baseline and after the second course of NAC. Changes to imaging parameters [maximum standardized uptake value (SUV max ), metabolic tumor volume (MTV), total lesion glycolysis (TLG)] and textural features (entropy, coarseness, skewness) between the 2 scans were measured by two independent radiologists. Pathological responses were reviewed by one pathologist, and the significance of the predictive value of each parameter was analyzed using a Chi-squared test. Receiver operating characteristic curve analysis was used to compare the area under the curve (AUC) for each parameter. pCR was observed more often in patients with HER2-positive tumors (22 patients) than in patients with HER2-negative tumors (5 patients) (71.0 vs. 16.7%, p textural features of 18 F-FDG PET images after two cycles of NAC are predictive of pCR in both HER2-negative and HER2-positive patients; this evidence warrants confirmation by further research.

  5. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Jainil P., E-mail: jainil.shah@duke.edu [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); Mann, Steve D. [Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 and Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States); McKinley, Randolph L. [ZumaTek, Inc., Research Triangle Park, North Carolina 27709 (United States); Tornai, Martin P. [Department of Biomedical Engineering, Duke University, Durham, North Carolina 27705 (United States); Medical Physics Graduate Program, Duke University Medical Center, Durham, North Carolina 27705 (United States); Multi Modality Imaging Lab, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2015-08-15

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm{sup 3} voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  6. Three dimensional dose distribution comparison of simple and complex acquisition trajectories in dedicated breast CT

    International Nuclear Information System (INIS)

    Shah, Jainil P.; Mann, Steve D.; McKinley, Randolph L.; Tornai, Martin P.

    2015-01-01

    Purpose: A novel breast CT system capable of arbitrary 3D trajectories has been developed to address cone beam sampling insufficiency as well as to image further into the patient’s chest wall. The purpose of this study was to characterize any trajectory-related differences in 3D x-ray dose distribution in a pendant target when imaged with different orbits. Methods: Two acquisition trajectories were evaluated: circular azimuthal (no-tilt) and sinusoidal (saddle) orbit with ±15° tilts around a pendant breast, using Monte Carlo simulations as well as physical measurements. Simulations were performed with tungsten (W) filtration of a W-anode source; the simulated source flux was normalized to the measured exposure of a W-anode source. A water-filled cylindrical phantom was divided into 1 cm"3 voxels, and the cumulative energy deposited was tracked in each voxel. Energy deposited per voxel was converted to dose, yielding the 3D distributed dose volumes. Additionally, three cylindrical phantoms of different diameters (10, 12.5, and 15 cm) and an anthropomorphic breast phantom, initially filled with water (mimicking pure fibroglandular tissue) and then with a 75% methanol-25% water mixture (mimicking 50–50 fibroglandular-adipose tissues), were used to simulate the pendant breast geometry and scanned on the physical system. Ionization chamber calibrated radiochromic film was used to determine the dose delivered in a 2D plane through the center of the volume for a fully 3D CT scan using the different orbits. Results: Measured experimental results for the same exposure indicated that the mean dose measured throughout the central slice for different diameters ranged from 3.93 to 5.28 mGy, with the lowest average dose measured on the largest cylinder with water mimicking a homogeneously fibroglandular breast. These results align well with the cylinder phantom Monte Carlo studies which also showed a marginal difference in dose delivered by a saddle trajectory in the

  7. Income, productivity, and satisfaction of breast surgeons.

    Science.gov (United States)

    Bendorf, David C; Helmer, Stephen D; Osland, Jacqueline S; Tenofsky, Patty L

    2010-03-01

    The purpose of this study was to assess how the practice patterns of breast surgeons affect their income and job satisfaction. A 19-question survey regarding practice patterns and income and job satisfaction was mailed to all active US members of the American Society of Breast Surgeons. There were 772 responses. An increasing percentage of breast care was associated with lower incomes (P=.0001) and similar income satisfaction (P=.4517) but higher job satisfaction (P=.0001). The increasing proportion of breast care was also associated with fewer hours worked per week (P=.0001). Although incomes were lower in surgeons with a higher proportion of their practice in breast care, income satisfaction was not affected. Although cause and effect relationships between income and breast surgery are difficult to establish, several trends do emerge. Most significantly, we found that dedicated breast surgeons have higher job satisfaction ratings and similar income satisfaction despite lower incomes. Copyright (c) 2010 Elsevier Inc. All rights reserved.

  8. Initial validation of 4D-model for a clinical PET scanner using the Monte Carlo code gate

    International Nuclear Information System (INIS)

    Vieira, Igor F.; Lima, Fernando R.A.; Gomes, Marcelo S.; Vieira, Jose W.; Pacheco, Ludimila M.; Chaves, Rosa M.

    2011-01-01

    Building exposure computational models (ECM) of emission tomography (PET and SPECT) currently has several dedicated computing tools based on Monte Carlo techniques (SimSET, SORTEO, SIMIND, GATE). This paper is divided into two steps: (1) using the dedicated code GATE (Geant4 Application for Tomographic Emission) to build a 4D model (where the fourth dimension is the time) of a clinical PET scanner from General Electric, GE ADVANCE, simulating the geometric and electronic structures suitable for this scanner, as well as some phenomena 4D, for example, rotating gantry; (2) the next step is to evaluate the performance of the model built here in the reproduction of test noise equivalent count rate (NEC) based on the NEMA Standards Publication NU protocols 2-2007 for this tomography. The results for steps (1) and (2) will be compared with experimental and theoretical values of the literature showing actual state of art of validation. (author)

  9. Initial validation of 4D-model for a clinical PET scanner using the Monte Carlo code gate

    Energy Technology Data Exchange (ETDEWEB)

    Vieira, Igor F.; Lima, Fernando R.A.; Gomes, Marcelo S., E-mail: falima@cnen.gov.b [Centro Regional de Ciencias Nucleares do Nordeste (CRCN-NE/CNEN-PE), Recife, PE (Brazil); Vieira, Jose W.; Pacheco, Ludimila M. [Instituto Federal de Educacao, Ciencia e Tecnologia (IFPE), Recife, PE (Brazil); Chaves, Rosa M. [Instituto de Radium e Supervoltagem Ivo Roesler, Recife, PE (Brazil)

    2011-07-01

    Building exposure computational models (ECM) of emission tomography (PET and SPECT) currently has several dedicated computing tools based on Monte Carlo techniques (SimSET, SORTEO, SIMIND, GATE). This paper is divided into two steps: (1) using the dedicated code GATE (Geant4 Application for Tomographic Emission) to build a 4D model (where the fourth dimension is the time) of a clinical PET scanner from General Electric, GE ADVANCE, simulating the geometric and electronic structures suitable for this scanner, as well as some phenomena 4D, for example, rotating gantry; (2) the next step is to evaluate the performance of the model built here in the reproduction of test noise equivalent count rate (NEC) based on the NEMA Standards Publication NU protocols 2-2007 for this tomography. The results for steps (1) and (2) will be compared with experimental and theoretical values of the literature showing actual state of art of validation. (author)

  10. Metabolic impact of partial volume correction of [18F]FDG PET-CT oncological studies on the assessment of tumor response to treatment.

    Science.gov (United States)

    Stefano, A; Gallivanone, F; Messa, C; Gilardi, M C; Gastiglioni, I

    2014-12-01

    The aim of this work is to evaluate the metabolic impact of Partial Volume Correction (PVC) on the measurement of the Standard Uptake Value (SUV) from [18F]FDG PET-CT oncological studies for treatment monitoring purpose. Twenty-nine breast cancer patients with bone lesions (42 lesions in total) underwent [18F]FDG PET-CT studies after surgical resection of breast cancer primitives, and before (PET-II) chemotherapy and hormone treatment. PVC of bone lesion uptake was performed on the two [18F]FDG PET-CT studies, using a method based on Recovery Coefficients (RC) and on an automatic measurement of lesion metabolic volume. Body-weight average SUV was calculated for each lesion, with and without PVC. The accuracy, reproducibility, clinical feasibility and the metabolic impact on treatment response of the considered PVC method was evaluated. The PVC method was found clinically feasible in bone lesions, with an accuracy of 93% for lesion sphere-equivalent diameter >1 cm. Applying PVC, average SUV values increased, from 7% up to 154% considering both PET-I and PET-II studies, proving the need of the correction. As main finding, PVC modified the therapy response classification in 6 cases according to EORTC 1999 classification and in 5 cases according to PERCIST 1.0 classification. PVC has an important metabolic impact on the assessment of tumor response to treatment by [18F]FDG PET-CT oncological studies.

  11. Direct Comparison of Radiolabeled Probes FMAU, FHBG, and FHPG as PET Imaging Agents for HSV1-tk Expression in a Human Breast Cancer Model

    Directory of Open Access Journals (Sweden)

    Mian M. Alauddin

    2004-04-01

    Full Text Available 2′-Deoxy-2′-fluoro-5-methyl-1-β-d-arabinofuranosyluracil (FMAU, 9-(4-fluoro-3-hydroxy-methyl-butylguanine (FHBG and 9-[(3-fluoro-1-hydroxy-2-propoxymethyl]-guanine (FHPG have been evaluated in a human breast cancer model as potential radiotracers for PET imaging of HSV1-tk gene expression. In vitro accumulation of [14C]FMAU, [18F]FHBG, and [18F]FHPG in HSV1-tk-expressing cells was 14- to 16-fold (p < .001, 9- to 13-fold (p < .001, and 2- to 3-fold (p < .05 higher than tk-negative control cells, respectively, between 30 and 240 min. Accumulation of FMAU and FHBG in vector-transduced cells was 10- to 14-fold and 6- to 10-fold higher than wild-type cells, respectively. At 2 hr, uptake of [14C]FMAU in tk-positive cells was 6.3-fold and 60-fold higher than [18F]FHBG and [18F]FHPG, respectively. In vivo, tumor uptake of [14C]FMAU in HSV1-tk-expressing cells was 3.7-fold and 5.5-fold (p < .001 higher than tk-negative control cells at 1 and 2 hr, respectively. Tumor uptake of [18F]FHBG was 4.2-fold and 12.6-fold higher (p < .001 than tk-negative cells at the same time points. Incorporation of [14C]FMAU in tk-positive tumor was 18-fold and 24-fold higher (p < .001 than [18F]FHBG at 1 and 2 hr, respectively. Micro-PET images support the biodistribution results and indicate that both [18F]FMAU and [18F]FHBG are useful for imaging HSV1-tk expression in breast cancer. Although FMAU demonstrates higher total incorporation (%dose/g in tumor tissue compared with the other tracers, FHBG is superior in terms of specific accumulation in transfected cells at later time points.

  12. Cost-effectiveness of FDG-PET for the management of potentially operable non-small cell lung cancer: priority for a PET-based strategy after nodal-negative CT results

    International Nuclear Information System (INIS)

    Dietlein, M.; Weber, K.; Moka, D.; Theissen, P.; Schicha, H.

    2000-01-01

    Decision analysis is used here to establish the most cost-effective strategy for management of potentially operable non-small cell lung cancers (NSCLCs). The strategies compared were conventional staging (strategy A), dedicated systems of positron emission tomography (PET) using fluorine-18 fluorodeoxyglucose (FDG) in patients with normal-sized (strategy B) or in patients with enlarged mediastinal lymph nodes (part of strategy C), and FDG-PET followed by exclusion from surgical procedures when both computed tomography (CT) and PET were positive for mediastinal lymph nodes (strategy D) or when PET alone was positive (strategy E). Based on published data, the sensitivity and specificity of FDG-PET were estimated at 0.74 and 0.96 for detecting metastasis in normal-sized mediastinal lymph nodes, and at 0.95 and 0.76 when these lymph nodes were enlarged. The calculated probability of up-staging to M1 by using PET was 0.05. The costs quoted correspond to the cost reimbursed in 1999 by the public health provider in Germany. The incremental cost-effectiveness ratio (ICER) of strategy B was much more favourable (143 EUR/LYS; LYS = life year saved) than the ICER of strategy C (36,667 EUR/LYS). In strategy B, the use of PET did not raise the overall costs because the costs of PET were almost balanced by a better selection of patients for beneficial cancer resection. The exclusion from biopsy confirmation in strategies D and E led to cost savings that did not justify the expected reduction in life expectancy. In sensitivity analyses, the ICERs of strategy B were robust to the pretest likelihood of N2/N3, to penalized test parameters of PET and to reimbursement of PET. However, the ICER of strategy B would be raised to 28,000 EUR/LYS through use of thoracic PET without whole-body scanning. To conclude, the implementation of whole-body PET with a full ring of detectors in the preoperative staging of patients with NSCLC and normal-sized lymph nodes is clearly cost

  13. Development of a liquid xenon Compton telescope dedicated to functional medical imaging

    International Nuclear Information System (INIS)

    Grignon, C.

    2007-12-01

    Functional imaging is a technique used to locate in three dimensions the position of a radiotracer previously injected in a patient. The two main modalities used for a clinical application to detect tumors, the SPECT and the PET, use solid scintillators as a detection medium. The objective of this thesis was to investigate the possibility of using liquid xenon in order to benefit from the intrinsic properties of this medium in functional imaging. The feasibility study of such a device has been performed by taking into account the technical difficulties specific to the liquid xenon. First of all, simulations of a liquid xenon PET has been performed using Monte-Carlo methods. The results obtained with a large liquid xenon volume are promising : we can expect a reduction of the injected activity of radiotracer, an improvement of the spatial resolution of the image and a parallax free camera. The second part of the thesis was focused on the development of a new concept of medical imaging, the three gamma imaging, based on the use of a new emitter: the 44 scandium. Associated to a classical PET camera, the Compton telescope is used to infer the incoming direction of the third gamma ray by triangulation. Therefore, it is possible to reconstruct the position of each emitter in three dimensions. This work convinced the scientific community to support the construction and characterization of a liquid xenon Compton telescope. The first camera dedicated to small animal imaging should then be operational in 2009. (author)

  14. WE-DE-207B-12: Scatter Correction for Dedicated Cone Beam Breast CT Based On a Forward Projection Model

    Energy Technology Data Exchange (ETDEWEB)

    Shi, L; Zhu, L [Georgia Institute of Technology, Atlanta, GA (Georgia); Vedantham, S; Karellas, A [University of Massachusetts Medical School, Worcester, MA (United States)

    2016-06-15

    Purpose: The image quality of dedicated cone-beam breast CT (CBBCT) is fundamentally limited by substantial x-ray scatter contamination, resulting in cupping artifacts and contrast-loss in reconstructed images. Such effects obscure the visibility of soft-tissue lesions and calcifications, which hinders breast cancer detection and diagnosis. In this work, we propose to suppress x-ray scatter in CBBCT images using a deterministic forward projection model. Method: We first use the 1st-pass FDK-reconstructed CBBCT images to segment fibroglandular and adipose tissue. Attenuation coefficients are assigned to the two tissues based on the x-ray spectrum used for imaging acquisition, and is forward projected to simulate scatter-free primary projections. We estimate the scatter by subtracting the simulated primary projection from the measured projection, and then the resultant scatter map is further refined by a Fourier-domain fitting algorithm after discarding untrusted scatter information. The final scatter estimate is subtracted from the measured projection for effective scatter correction. In our implementation, the proposed scatter correction takes 0.5 seconds for each projection. The method was evaluated using the overall image spatial non-uniformity (SNU) metric and the contrast-to-noise ratio (CNR) with 5 clinical datasets of BI-RADS 4/5 subjects. Results: For the 5 clinical datasets, our method reduced the SNU from 7.79% to 1.68% in coronal view and from 6.71% to 3.20% in sagittal view. The average CNR is improved by a factor of 1.38 in coronal view and 1.26 in sagittal view. Conclusion: The proposed scatter correction approach requires no additional scans or prior images and uses a deterministic model for efficient calculation. Evaluation with clinical datasets demonstrates the feasibility and stability of the method. These features are attractive for clinical CBBCT and make our method distinct from other approaches. Supported partly by NIH R21EB019597, R21CA134128

  15. A small animal PET prototype based on Silicon Photomultipliers

    International Nuclear Information System (INIS)

    Marcatili, S; Belcari, N.; Bisogni, M.G.; Del Guerra, A.; Collazuol, G.; Pedreschi, E.; Spinella, F.; Sportelli, G.; Marzocca, C.

    2011-01-01

    Next generation PET scanners should full fill very high requirements in terms of spatial, energy and timing resolution. Modern scanner performances are inherently limited by the use of standard photomultiplier tubes. The use of Silicon Photomultiplier (Si P M) matrices is proposed for the construction of a small animal PET system consisting of two detector heads based on Lyso continuos crystals. The use of large area multi-pixel Silicon Photomultiplier (Si P M) detectors requires the development of a multichannel Digital Acquisition system (DAQ) as well as of a dedicated front-end in order not to degrade the intrinsic detector capabilities. At the University of Pisa and INFN Pisa we developed a DAQ board for the read-out of 2 64-pixel Si P M matrices in time coincidence for Positron Emission Tomography (PET) applications. The proof of principles is based on 64-pixel detectors, but the whole system has been conceived to be easily scalable to a higher number of channels. Here we describe the Group-V INFN DASi P M 2 (Development and Application of Si P M) project and related results.

  16. {sup 18}F-FLT PET/CT as an imaging tool for early prediction of pathological response in patients with locally advanced breast cancer treated with neoadjuvant chemotherapy: a pilot study

    Energy Technology Data Exchange (ETDEWEB)

    Crippa, Flavio; Padovano, Barbara; Alessi, Alessandra; Bombardieri, Emilio; Pascali, Claudio; Bogni, Anna [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Nuclear Medicine Unit; Agresti, Roberto; Maugeri, Ilaria; Rampa, Mario; Martelli, Gabriele [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Breast Surgery Unit; Sandri, Marco [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Molecular Targeting Unit; Mariani, Gabriella; Bianchi, Giulia; De Braud, Filippo [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Medical Oncology Unit; Carcangiu, Maria Luisa [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Pathology Unit; Trecate, Giovanna [Fondazione IRCCS Istituto Nazionale dei Tumori, Milan (Italy). Radiology-RMI Unit

    2015-05-01

    We evaluated whether {sup 18}F-3'-deoxy-3'-fluorothymidine positron emission tomography (FLT PET) can predict the final postoperative histopathological response in primary breast cancer after the first cycle of neoadjuvant chemotherapy (NCT). In this prospective cohort study of 15 patients with locally advanced operable breast cancer, FLT PET evaluations were performed before NCT, after the first cycle of NCT, and at the end of NCT. All patients subsequently underwent surgery. Variables from FLT PET examinations were correlated with postoperative histopathological results. At baseline, median of maximum standardized uptake values (SUV{sub max}) in the groups showing a complete pathological response (pCR) + residual cancer burden (RCB) I, RCB II or RCB III did not differ significantly for the primary tumour (5.0 vs. 2.9 vs. 8.9, p = 0.293) or for axillary nodes (7.9 vs. 1.6 vs. 7.0, p = 0.363), whereas the Spearman correlation between SUV{sub max} and Ki67 proliferation rate index was significant (r = 0.69, p < 0.001). Analysis of the relative percentage change of SUV{sub max}in the primary tumour (∇SUVT{sub max}(t{sub 1})) and axillary nodes (∇SUVN{sub max}(t{sub 1})) after the first NCT cycle showed that the power of ∇SUVT{sub max}(t{sub 1}) to predict pCR + RCB I responses (AUC = 0.91, p < 0.001) was statistically significant, whereas ∇SUVN{sub max}(t{sub 1}) had a moderate ability (AUC = 0.77, p = 0.119) to separate subjects with ΔSUVT{sub max}(t{sub 1}) > -52.9 % into two groups: RCB III patients and a heterogeneous group that included RCB I and RCB II patients. A predictive score μ based on ΔSUVT{sub max}(t{sub 1}) and ΔSUVN{sub max}(t{sub 1}) parameters is proposed. The preliminary findings of the present study suggest the potential utility of FLT PET scans for early monitoring of response to NCT and to formulate a therapeutic strategy consistent with the estimated efficacy of NCT. However, these results in a small patient population

  17. Initial Experience With Simultaneous 18F-FDG PET/MRI in the Evaluation of Cardiac Sarcoidosis and Myocarditis.

    Science.gov (United States)

    Hanneman, Kate; Kadoch, Michael; Guo, Henry H; Jamali, Mehran; Quon, Andrew; Iagaru, Andrei; Herfkens, Robert

    2017-07-01

    The purpose of this study was to compare combined PET/MRI with PET/CT and cardiac MRI in the evaluation of cardiac sarcoidosis and myocarditis. Ten patients (4 men and 6 women; 56.1 ± 9.6 years old) were prospectively enrolled for evaluation of suspected cardiac sarcoidosis or myocarditis. Written informed consent was obtained. Following administration of 9.9 ± 0.9 mCi F-FDG, patients underwent standard cardiac PET/CT followed by combined PET/MRI using a simultaneous 3-T scanner. Cardiac MRI sequences included ECG-triggered cine SSFP, T2-weighted, and late gadolinium-enhanced imaging. Myocardial involvement was assessed with separate analysis of combined PET/MRI, PET/CT, and cardiac MRI data using dedicated postprocessing software. Estimates of radiation dose were derived from the applied doses of F-FDG and CT protocol parameters. Imaging was acquired with a delay from F-FDG injection of 90.2 ± 27.4 minutes for PET/CT and 207.7 ± 40.3 minutes for PET/MRI. Total scan time for PET/MRI was significantly longer than for PET/CT (81.4 ± 14.8 vs 12.0 minutes, P PET/MRI compared with PET/CT (6.9 ± 0.6 vs 8.2 ± 1.1 mSv, P = 0.007). There was no significant difference in the number of positive cases identified between combined PET/MRI (n = 10 [100%]), PET/CT (n = 6 [60%]), and cardiac MRI (n = 8 [80%]), P = 0.091. Simultaneous cardiac PET/MRI is feasible in the evaluation of cardiac sarcoidosis and myocarditis achieving diagnostic image quality.

  18. The Use of Novel PET Tracers to Image Breast Cancer Biologic Processes Such as Proliferation, DNA Damage and Repair, and Angiogenesis.

    Science.gov (United States)

    Kenny, Laura

    2016-02-01

    The balance between proliferation and cell death is pivotal to breast tumor growth. Because of a combination of environmental and genetic factors leading to activation of oncogenes or inactivation of tumor suppressor genes, these processes become deregulated in cancer. PET imaging of proliferation, angiogenesis, and DNA damage and repair offers the opportunity to monitor therapeutic efficacy to detect changes in tumor biology that may precede physical size reduction and simultaneously allows the study of intratumoral and intertumoral heterogeneity.This review examines recent developments in breast cancer imaging using novel probes. The probes discussed here are not licensed for routine use and are at various stages of development ranging from preclinical development (e.g., the DNA repair marker γH2AX) to clinical validation in larger studies (such as the proliferation probe 3'-deoxy-3'-(18)F-fluorothymidine [(18)F-FLT]). In breast cancer, most studies have focused on proliferation imaging mainly based on (18)F-labeled thymidine analogs. Initial studies have been promising; however, the results of larger validation studies are necessary before being incorporated into routine clinical use. Although there are distinct advantages in using process-specific probes, properties such as metabolism need careful consideration, because high background uptake in the liver due to glucuronidation in the case of (18)F-FLT may limit utility for imaging of liver metastases.Targeting angiogenesis has had some success in tumors such as renal cell carcinoma; however, angiogenesis inhibitors have not been particularly successful in the clinical treatment of breast cancer. This could be potentially attributed to patient selection due to the lack of validated predictive and responsive biomarkers; the quest for a successful noninvasive biomarker for angiogenesis could solve this challenge. Finally, we look at cell death including apoptosis and DNA damage and repair probes, the most well

  19. FDG-PET imaging for chronic expanding hematoma in pelvis with massive bone destruction

    Energy Technology Data Exchange (ETDEWEB)

    Hamada, Kenichiro [Osaka University Graduate School of Medicine, Department of Nuclear Medicine and Tracer Kinetics, Suita, Osaka (Japan); Osaka University Graduate School of Medicine, Department of Orthopaedic Surgery, Suita, Osaka (Japan); Myoui, Akira; Ueda, Takafumi; Tamai, Noriyuki; Yoshikawa, Hideki [Osaka University Graduate School of Medicine, Department of Orthopaedic Surgery, Suita, Osaka (Japan); Higuchi, Ichiro; Hatazawa, Jun [Osaka University Graduate School of Medicine, Department of Nuclear Medicine and Tracer Kinetics, Suita, Osaka (Japan); Inoue, Atsuo [Osaka University Graduate School of Medicine, Department of Radiology, Suita, Osaka (Japan)

    2005-12-01

    Chronic expanding hematoma is a rare presentation of a hematoma characterized by a persistent increase in size for more than a month after the initial hemorrhage. We present a 65-year-old man with a chronic expanding hematoma in his ilium who was receiving anticoagulant treatment. The patient had a delayed manifestation of a femoral neuropathy with massive bone destruction. 2-Deoxy-[{sup 18}F]fluoro-d-glucose (FDG) positron emission tomography (PET) imaging revealed an increased uptake in the rim of the mass in images acquired 1 h after FDG injection. FDG-PET scans were performed using a dedicated PET scanner (HeadtomeV/SET2400 W, Shimadzu, Kyoto, Japan), and the PET data for the most metabolically active region of interest (ROI) were analyzed. The maximum standardized uptake value (SUVmax) was set to a cut-off point of 3.0 to distinguish between benign and malignant lesions. The SUVmax of the patient's lesion was 3.10, suggesting a malignant lesion. The characteristics of FDG-PET images of chronic expanding hematomas, including the uptake of FDG in the peripheral rim of the mass as a result of inflammation, should be recognized as a potential interpretive pitfall in mimicking a sarcoma. (orig.)

  20. 18F-FDG uptake in breast cancer correlates with immunohistochemically defined subtypes

    International Nuclear Information System (INIS)

    Koo, Hye Ryoung; Park, Jeong Seon; Kang, Keon Wook; Cho, Nariya; Chang, Jung Min; Bae, Min Sun; Kim, Won Hwa; Lee, Su Hyun; Seo, Mirinae; Moon, Woo Kyung; Kim, Mi Young; Kim, Jin You

    2014-01-01

    To determine whether a correlation exists between maximum standardized uptake value (SUV max ) on 18 F-fluorodeoxyglucose positron emission tomography (FDG-PET) and the subtypes of breast cancer. This retrospective study involved 548 patients (mean age 51.6 years, range 21-81 years) with 552 index breast cancers (mean size 2.57 cm, range 1.0-14.5 cm). The correlation between 18 F-FDG uptake in PET/CT, expressed as SUV max , and immunohistochemically defined subtypes (luminal A, luminal B, human epidermal growth factor receptor 2 (HER2) positive and triple negative) was analyzed. The mean SUV max value of the 552 tumours was 6.07 ± 4.63 (range 0.9-32.8). The subtypes of the 552 tumours were 334 (60 %) luminal A, 66 (12 %) luminal B, 60 (11 %) HER2 positive and 92 (17 %) triple negative, for which the mean SUV max values were 4.69 ± 3.45, 6.51 ± 4.18, 7.44 ± 4.73 and 9.83 ± 6.03, respectively. In a multivariate regression analysis, triple-negative and HER2-positive tumours had 1.67-fold (P max values, respectively, than luminal A tumours after adjustment for invasive tumour size, lymph node involvement status and histologic grade. FDG uptake was independently associated with subtypes of invasive breast cancer. Triple-negative and HER2-positive breast cancers showed higher SUV max values than luminal A tumours. circle 18 F-FDG PET demonstrates increased tissue glucose metabolism, a hallmark of cancers. (orig.)