WorldWideScience

Sample records for cyberknife stereotactic radiotherapy

  1. Extracranial stereotactic radiotherapy: preliminary results with the CyberKnife.

    Science.gov (United States)

    Lartigau, Eric; Mirabel, Xavier; Prevost, Bernard; Lacornerie, Thomas; Dubus, Francois; Sarrazin, Thierry

    2009-04-01

    In the field of radiation oncology, equipment for fractionated radiotherapy and single-dose radiosurgery has become increasingly accurate, together with the introduction of robotized treatments. A robot is a device that can be programmed to carry out accurate, repeated and adjusted tasks in a given environment. Treatment of extracranial lesions involves taking into account organ mobility (tumor and healthy tissue) whilst retaining the ability to stereotactically locate the target. New imaging techniques (single-photon emission computed tomography (SPECT), magnetic resonance imaging (MRI), positron emission tomography (PET)) provide further relevant information to slice images (computed tomography (CT) scans, MRI) for target definition. Hypo-fractionated treatments can only be used for curative treatment if the target is accurately defined and tracked during treatment. The CyberKnife is a non-invasive system of radiosurgery and fractionated stereotactic radiotherapy. For intracranial lesions treated by single-dose radiosurgery, it has been used to treat meningioma, acoustic neuromas, pituitary adenoma, metastases, arteriovenous malformations and refractory pain (trigeminal neuralgia). More than 10,000 patients have been treated worldwide. Currently, the most significant developments are in the field of extracranial stereotactic radiotherapy (lung, liver, reirradiation, prostate, etc.). Clinical results obtained in the CyberKnife Nord-Ouest program after 1 year of experience are presented. Copyright 2009 S. Karger AG, Basel.

  2. CyberKnife robotic stereotactic radiotherapy: technical aspects and medical indications; Radiotherapie stereotaxique robotisee par CyberKnife: aspects techniques et indications

    Energy Technology Data Exchange (ETDEWEB)

    Bondiau, P.Y.; Benezery, K.; Gerard, J.P.; Herault, J.; Marcie, S.; Angellier, G. [Centre Antoine-Lacassagne, Dept. de Radiotherapie, 06 - Nice (France); Beckendorf, V.; Peiffert, D.; Noel, A. [Centre Alexis-Vautrin, Dept. de Radiotherapie et Curietherapie, 54 - Vandoeuvre-les-Nancy (France); Mirabel, X.; Marchesi, V.; Lacornerie, T.; Dubus, F.; Sarrazin, T.; Lartigau, E. [Centre Oscar-Lambret, Dept. de Radiotherapie, 59 - Lille (France)

    2007-11-15

    In 2006, 3 sites have been selected by the Institut national of cancer (Lille, Nancy et Nice) to evaluate a radiotherapy robot, the CyberKnife this machine, able to track mobile tumours in real time, gives new possibilities in the field of extra cranial stereotactic radiotherapy. Functionalities and medico economical issues of the machine will be evaluated during 2 years on the 3 sites. (authors)

  3. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids

    International Nuclear Information System (INIS)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E.

    2009-01-01

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  4. Fractionated stereotactic irradiation by Cyberknife of choroid melanomas: repositioning validation, closed eyelids; Irradiation stereotaxique fractionnee par Cyberknife des melanomes choroidiens: validation du repositionnement, paupieres fermees

    Energy Technology Data Exchange (ETDEWEB)

    Horn, S.; Rezvoy, N.; Lacornerie, T.; Mirabel, X.; Labalette, P.; Lartigau, E. [Centre Oscar-Lambret, Service de Radiotherapie, 59 - Lille (France)

    2009-10-15

    The fractionated stereotactic radiotherapy by Cyberknife is an option in the treatment of eyes tumors. The advantages of the Cyberknife in the choroid melanomas are in its infra-millimetric precision, to the automated repositioning on the skull bones and to the conformity brought by the stereotaxy. The objective of this study was to validate the quality of repositioning and the immobility of the eyes with closed eyelids. Conclusion: the reproducibility of the eye positioning with closed eyelids seems enough to consider the conservative treatment of choroid melanomas by fractionated stereotactic radiotherapy by Cyberknife without implementation of fiducials nor retrobulbar anaesthesia. (N.C.)

  5. St. Joseph's Hospital Barrow Neurological Institute stereitatic radiotherapy experience comparison of Gamma Knife and CyberKnife

    International Nuclear Information System (INIS)

    Kresl, J.J.

    2006-01-01

    The clinical utilisation stereotactic radiotherapy continues to increase in breadth and scope within the medical community. However, no single standard treatment platform exists for the delivery of stereotactic radiotherapy treatments. This is because although there are several commercially available platforms capable of delivering stereotactic radiotherapy treatments, each platform has unique abilities and limitations. The most widely used stereotactic radiotherapy system for intracranial treatments is the Gamma Knife. The first image guided robotic stereotactic radiotherapy system enabling body stereotactic radiotherapy is the CyberKnife. Both are available at the Barrow Neurological Institute. We describe our experience with the complementary use of these two distinct treatment platforms. This permits us to make a meaningful comparison and to detail their contrasting advantages and disadvantages for state of the art for stereotactic radiotherapy. (author)

  6. Non small cells stage I bronchial cancers: three-dimensional radiotherapy and radiotherapy in stereotactic conditions; Cancers bronchiques non a petites cellules de stade I: radiotherapie tridimensionnelle et radiotherapie en conditions stereotaxiques

    Energy Technology Data Exchange (ETDEWEB)

    Schipman, B.; Bosset, J.F. [CHU, 25 - Besancon (France); Marchesi, V.; Beckendorf, V.; Desandes, E.; Peiffert, D. [CRLCC Alexis-Vautrin, 54 - Vandaeuvre-les-Nancy (France); Bosset, M. [CHU, 26 - Valence (France)

    2010-10-15

    The authors report a comparison between three-dimensional conformation radiotherapy and robotic irradiation in stereotactic conditions (with CyberKnife) for patients suffering from a bronchial cancer with no small cells of stage I. Acute and late toxicity have been recorded, and the monitoring comprised a clinic examination and a thoracic scanography. The external radiotherapy results in an important local control rate and an acceptable toxicity. Some prospective studies are still needed to compare three-dimensional conformation respiratory-gated radiotherapy and radiotherapy in stereotactic conditions. Short communication

  7. Cyberknife stereotactic treatment

    International Nuclear Information System (INIS)

    Lief, Eugene

    2008-01-01

    The topic discussed included, among others, the following: cyberknife capabilities; autonomous robotics; continuous image guidance; flexible robotics maneuverability; Dynamic motion targeting; intelligent patient positioning; 4D treatment optimization and planning system; X-ray sources; robotic manipulator; linear accelerator; MultiPlan treatment planning system; radiosurgery vs radiotherapy; radiation system delivery comparison; simplified contouring; plan optimization; QA and commissioning. (P.A.)

  8. Cyberknife fractionated radiotherapy for adrenal metastases: Preliminary report from a multispecialty Indian cancer care center

    Directory of Open Access Journals (Sweden)

    Trinanjan Basu

    2015-03-01

    Full Text Available Purpose: Metastasis to adrenal gland from lung, breast, and kidney malignancies are quite common. Historically radiotherapy was intended for pain palliation. Recent studies with stereotactic body radiotherapy (SBRT including Cyberknife robotic radiosurgery aiming at disease control brings about encouraging results. Here we represent the early clinical experience with Cyberknife stereotactic system from an Indian cancer care center. The main purpose of this retrospective review is to serve as a stepping stone for future prospective studies with non- invasive yet effective technique compared to surgery. Methods: We retrospectively reviewed four cases of adrenal metastases (three: lung and one: renal cell carcinoma treated with Cyberknife SBRT. X sight spine tracking was employed for planning and treatment delivery. Patients were evaluated for local response clinically as well as with PETCT based response criteria.Results: With a median gross tumor volume of 20.5 cc and median dose per fraction of 10 Gy, two patients had complete response (CR and two had partial response (PR when assessed 8-12 weeks post treatment as per RECIST. There was no RTOG grade 2 or more acute adverse events and organs at risk dosage were acceptable. Till last follow up all the patients were locally controlled and alive. Conclusion: Cyberknife SBRT with its unique advantages like non- invasive, short duration outpatient treatment technique culminating in similar local control rates in comparison to surgery is an attractive option. World literature of linear accelerator based SBRT and our data with Cyberknife SBRT with small sample size and early follow up are similar in terms of local control in adrenal metastases. Future prospective data would reveal more information on the management of adrenal metastases.

  9. Stereotactic radiotherapy by cyberknife of sub-diaphragm digestive tumors; Radiotherapie stereotaxique par Cyberknife des tumeurs digestives sous diaphragmatiques

    Energy Technology Data Exchange (ETDEWEB)

    Taste, H.; Peiffert, D.; Beckendorf, V.; Marchesi, V.; Noel, A. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France)

    2009-10-15

    The stereotactic radiotherapy is a low toxic, efficient therapy offering a supplementary curative alternative, with promising first results, confirmed by literature. ts indications, its place in the therapy strategy stay to determine in the clinical research program. (N.C.)

  10. A retrospective review of Cyberknife Stereotactic Body Radiotherapy for Adrenal Tumors (Primary and Metastatic: Winthrop University Hospital experience

    Directory of Open Access Journals (Sweden)

    Amishi eDesai

    2015-08-01

    Full Text Available The adrenal gland is a common site of cancer metastasis. Surgery remains a mainstay of treatment for solitary adrenal metastasis. For patients who cannot undergo surgery, radiation is an alternative option. Stereotactic body radiotherapy (SBRT is an ablative treatment option allowing larger doses to be delivered over a shorter period of time. In this study, we report on our experience with the use of SBRT to treat adrenal metastases using Cyberknife technology. We retrospectively reviewed, the Winthrop-University radiation oncology data base to identify 14 patients for whom SBRT was administered to treat malignant adrenal disease. Of the factors examined, the biologic equivalent dose (BED of radiation delivered was found to be the most important predictor of local adrenal tumor control. We conclude that CyberKnife-based SBRT is a safe, non-invasive modality that has broadened the therapeutic options for the treatment of isolated adrenal metastases.

  11. Lung tumor tracking during stereotactic radiotherapy treatment with the CyberKnife: Marker placement and early results

    International Nuclear Information System (INIS)

    Nuyttens, J.J.; Prevost, J.B.; Praag, J.; Hoogeman, M.; Levendag, P.C.; Klaveren, R.J. van; Pattynama, P.M.T.

    2006-01-01

    Lung tumor tracking during stereotactic radiotherapy with the CyberKnife requires the insertion of markers in or close to the tumor. To reduce the risk of pneumothorax, three methods of marker placement were used: 1) intravascular coil placement, 2) percutaneous intrathoracal, and 3) percutaneous extrathoracal placement. We investigated the toxicity of marker placement and the tumor response of the lung tumor tracking treatment. Markers were placed in 20 patients with 22 tumors: 13 patients received a curative treatment, seven a palliative. The median Charlson Comorbidity Score was 4 (range: 1-8). Platinum fiducials and intravascular embolisation coils were used as markers. In total, 78 markers were placed: 34 intrathoracal, 23 intravascular and 21 extrathoracal. The PTV equaled the GTV + 5 mm. A median dose of 45 Gy (range: 30-60 Gy, in 3 fractions) was prescribed to the 70-85% isodose. The response was evaluated with a CTscan performed 6-8 weeks after the last treatment and routinely thereafter. The median follow-up was 4 months (range: 2-11). No severe toxicity due to the marker placement was seen. Pneumothorax was not seen. The local control was 100%. Four tumors in four patients showed a complete response, 15 tumors in 14 patients a partial response, and three tumors in two patients with metastatic disease had stable disease. No severe toxicity of marker placement was seen due to the appropriate choice of one of the three methods. CyberKnife tumor tracking with markers is feasible and resulted in excellent tumor response. Longer follow-up is needed to validate the local control

  12. SU-E-T-395: Evaluation of Multiple Brain Metastases Stereotactic Treatment Planning in Cyberknife Versus Linac

    International Nuclear Information System (INIS)

    Vikraman, S; Rajesh, Thiyagarajan; Karrthick, Kp; Sambasivaselli, R; Senniandavar, V; Ramu, M; Maragathaveni, S; Dhivya, N; Tejinder, K; Manigandan, D; Muthukumaran, M

    2015-01-01

    Purpose: The purpose of this study was to evaluate multiple brain metastases stereotactic treatment planning of Cyberknife versus linac using dose volume based indices. Methods: Fifteen multiple brain metastases patients were taken for this study from Cyberknife Multiplan TPSv4.6.0. All these patients underwent stereotactic treatment in Cyberknife. For each patient VMAT stereotactic treatment plan was generated in MONACO TPSv5.0 using Elekta beam modulator MLC and matched the delivered plan. A median dose of 8.5Gy(range 7–12Gy) per fraction was prescribed. Tumor volume was in the range of 0.06–4.33cc. Treatment plan quality was critically evaluated by comparing DVH indices such as D98, D95, CI, and HI for target volumes. Maximum point doses and volume doses were evaluated for critical organs. Results: For each case, target coverage of D98 was achieved with 100% prescription dose with SD of 0.29% and 0.41% in Linac and Cyberknife respectively. The average conformity index(CI) of 1.26±0.0796 SD for Cyberknife and 1.92±0.60SD for linac were observed. Better homogeneity Index (HI) of 1.17±0.09SD was observed in linac as compared to Cyberknife HI of 1.24±0.05SD.All the critical organ doses were well within tolerance limit in both linac and Cyberknife plans. There is no significant difference of maximum point doses for brainstem and optic chiasm. Treatment time and number of monitor units are more in Cyberknife compared to linac. The average volume receiving 12Gy in whole brain was 6% and 12% for Cyberknife and linac respectively. 1000cc of whole brain received 60% lesser dose in Linac compared to Cyberknife in all cases. Conclusion: The study shows that dosimetrically comparable plans are achievable Cyberknife and Linac. However, a better conformity, target coverage, lesser OAR dose is achieved with Cyberknife due to greater degrees of freedom with robotic gantry and smaller collimator for multiple targets

  13. Spinal and para spinal tumors treated by Cyberknife: feasibility and efficacy

    International Nuclear Information System (INIS)

    Castelli, J.; Thariat, J.; Benezery, K.; Courdi, A.; Doyen, J.; Mammar, H.; Bondiau, P.Y.; Chanalet, S.; Paquis, P.; Frenay, M.

    2010-01-01

    Purpose Stereotactic radiotherapy using the Cyberknife has become a key treatment in the multidisciplinary management of secondary tumours, as well as primary benign or malignant tumours located within or adjacent to vertebral bodies and the spinal cord. The aim of this treatment is to improve local control and clinical response, including previously irradiated cases. Patients and methods In this study, we present the first patients treated with Cyberknife between December 2006 and December 2007 for spinal or para spinal tumours. The primary aim was to assess the feasibility and tolerance of stereotactic radiotherapy using the Cyberknife. Secondary aims were to establish the short-term local control, to calculate the local progression-free survival and overall survival. Clinical examination and imaging procedures were performed every three months. Response was assessed according to RECIST criteria. Results During that period, 16 patients were treated with Cyberknife. Thirteen patients had been pre-treated, three of whom had received spinal cord doses considered to be maximal. Three patients did not receive previous irradiation. The median age was 59 (36-74). The most frequent symptoms were pain (n = 8) and motor weakness (n = 4). The median dose was 30 Gy (16-50). The median number of fractions was 3 (1-5). No patient developed acute myelitis. Three patients developed acute reaction. Overall survival at 18 months was 72.4%, with a mean survival of 18.2 months (95% CI: 15.4-20.9). Local progression-free survival at 18 months was 58.4%, with a mean value of 16.9 months (95% CI: 13.6-20.2). Conclusion The use of stereotactic radiotherapy with Cyberknife represents a major progress in the management of para spinal tumours. The main advantages are better sparing of the spinal cord and the possibility of increasing the dose to the tumour target volume. (authors)

  14. Cyberknife : how has it changed the radiotherapy practice?

    International Nuclear Information System (INIS)

    Hukku, S.

    2016-01-01

    The CyberKnife is a frameless robotic radiosurgery system used for treating benign tumors, malignant tumors and other medical conditions. The system was invented by John R. Adler, a Stanford University professor of neurosurgery and radiation oncology, and Peter and Russell Schonberg of Schonberg Research Corporation. It is the most accurate and flexible tool available for aggressive therapeutic irradiation. It is a method of delivering radiotherapy, with the intention of targeting treatment more accurately than standard radiotherapy. The two main elements of the CyberKnife are: 1. The radiation produced from a small linear particle accelerator (linac) 2. A robotic arm which allows the energy to be directed at any part of the body from any direction. Several generations of the CyberKnife system have been developed since its initial inception in 1990

  15. Fractionated stereotactic radiotherapy as a boost treatment for tumors in the head and neck region

    International Nuclear Information System (INIS)

    Uno, Takashi; Isobe, Kouichi; Ueno, Naoyuki; Ito, Hisao; Fukuda, Ataru; Sudo, Satoshi; Shirotori, Hiroaki; Kitahara, Isao; Fukushima, Takanori

    2010-01-01

    The objective of this retrospective study was to report initial results of CyberKnife stereotactic radiotherapy (SRT) boost for tumors in the head and neck area. Between March 2008 and August 2009, 10 patients were treated with SRT boost using CyberKnife system due mainly to unfavorable condition such as tumors in close proximity to serial organs or former radiotherapy fields. Treatment sites were the external auditory canal in two, the nasopharynx in one, the oropharynx in three, the nasal cavity in one, the maxillary sinus in two, and the oligometastatic cervical lymph node in one. All patients underwent preceding conventional radiotherapy of 40 to 60 Gy. Dose and fractionation scheme of the Cyberknife SRT boost was individualized, and prescribed dose ranged from 9 Gy to 16 Gy in 3 to 4 fractions. Among four patients for whom dose to the optic pathway was concerned, the maximum dose was only about 3 Gy for three patients whereas 9.6 Gy in the remaining one patient. The maximum dose for the mandible in one of three patients with oropharyngeal cancer was 19.7 Gy, whereas majority of the bone can be spared by using non-isocentric conformal beams. For a patient with nasopharyngeal cancer, the highest dose in the brain stem was 15 Gy. However, majority of the brain stem received less than 40% of the maximum dose. Although a small volume high dose area within the normal structure could be observed in several patients, results of the present study showed potential benefits of the CyberKnife SRT boost. (author)

  16. Stereotactic radiotherapy in pediatric indications

    International Nuclear Information System (INIS)

    Bernier-Chastagner, V.; Supiot, S.; Carrie, C.; Helfre, S.

    2012-01-01

    Stereotactic radiotherapy is a very high precision procedure, which has been limited to radiosurgery for a long time. Technological improvements allowed the development of radiotherapy in stereotactic conditions, leading to a lot of innovations. Previously indicated for cerebral pathologies, this procedure is now developed for extra-cerebral locations. In paediatrics, stereotactic radiotherapy is still limited, delivered precociously, due to the possibility of long-term late effects that needs to be addressed. This review reports the different useful conditions, technical evolutions, and the current validated paediatric indications, with differences from adults, and future directions. (authors)

  17. The development of quality assurance program for cyberknife

    International Nuclear Information System (INIS)

    Jang, Ji Sun; Lee, Dong Han; Kang, Young Nam

    2006-01-01

    Standardization quality assurance (QA)program of Cyberknife for suitable circumstances in Korea has not been established. In this research, we investigated the development of QA program for Cyberknife and evaluation of the feasibility under applications. Considering the feature of constitution for systems and the therapeutic methodology of Cyberknife, the list of quality control (QC) was established and divided dependent on the each period of operations. And then all these developed QC lists were categorized into three groups such as basic QC, delivery specific QC, and patient specific QC based on the each purpose of QA. In order to verify the validity of the established QA program, this QC lists was applied to two Cyberknife centers. The acceptable tolerance was based on the undertaking inspection list from the Cyberknife manufacturer and the QC results during last three years of two Cyberknife centers in Korea. The acquired measurement results were evaluated for the analysis of the current QA status and the verification of the propriety for the developed QA program. The current QA status of two Cyberknife centers was evaluated from the accuracy of all measurements in relation with application of the established QA program. Each measurement result was verified having a good agreement within the acceptable tolerance limit of the developed QA program. It is considered that the developed QA program in this research could be established the standardization of QC methods for Cyberknife and confirmed the accuracy and stability for the image-guided stereotactic radiotherapy

  18. Robotic radiotherapy for prostate cancer with CyberKnife

    International Nuclear Information System (INIS)

    Hannoun-Levi, J.M.; Benezery, K.; Bondiau, P.Y.; Marcie, S.; Gerard, J.P.; Chamorey, E.

    2007-01-01

    After 3D conformal radiation therapy without and with modulated intensity, image-guided radiation therapy represents a new technological step. Should prostate cancer treatment using radiotherapy with the CyberKnife robotic system be considered as a new treatment and then investigated through classical clinical research procedure rather than a technical improvement of an already validated treatment? After a general presentation of the CyberKnife, the authors focused on prostate cancer treatment assuming that, according to dosimetric and biological considerations, the treatment by robotic system appears comparable to high dose rate brachytherapy. For prostate cancer treatment are discussed: biological rational for hypo fractionated treatment, high dose rate brachytherapy boost and interest of dose escalation. A comparison is presented between CyberKnife and other validated treatment for prostate cancer (radical prostatectomy, 3D conformal radiation therapy and low and high dose rate brachytherapy). In summary, CyberKnife treatment could be considered as a technical improvement of an already validated treatment in order to deliver a prostate boost after pelvic or peri-prostatic area irradiation. However, the clinical, biological and economical results must be precisely analyzed and could be assessed in the frame of a National Observatory based on shared therapeutic program. (authors)

  19. Predictive factors for the response of pulmonary tumours treated by robotic stereotactic radiotherapy; Facteurs predictifs pour la reponse des tumeurs pulmonaires traitees par radiotherapie stereotaxique robotisee

    Energy Technology Data Exchange (ETDEWEB)

    Doyen, J.; Benezery, K.; Thariat, J.; Angellier, G.; Poudenx, M.; Bondiau, P.Y. [Centre Antoine-Lacassagne, 06 - Nice (France); Beckendorf, V. [Centre Alexis-Vautrin, 54 - Nancy (France); Venissac, N. [Centre hospitalo-universitaire Pasteur, 06 - Nice (France)

    2010-10-15

    The authors report a study which aimed at identifying factors influencing the response to radiotherapy performed in robotic stereotactic conditions with CyberKnife within the frame of treatment of primitive or secondary pulmonary tumours. Thirty eight stage I cancers, 22 metastases including 17 epidermoid carcinomas, and 43 adenocarcinomas have been treated this way. The analysis of data and results reveals that feminine gender, a biological dose greater than 140 Gy, and an age greater than 65 year old are associated with a better tumour response. Short communication

  20. Stereotactic radiotherapy for vestibular schwannoma

    DEFF Research Database (Denmark)

    Muzevic, Dario; Legcevic, Jelena; Splavski, Bruno

    2014-01-01

    BACKGROUND: Vestibular schwannomas (acoustic neuromas) are common benign tumours that arise from the Schwann cells of the vestibular nerve. Management options include observation with neuroradiological follow-up, microsurgical resection and stereotactic radiotherapy. OBJECTIVES: To assess...... the effect of stereotactic radiotherapy compared to observation, microsurgical resection, any other treatment modality, or a combination of two or more of the above approaches for vestibular schwannoma. SEARCH METHODS: We searched the Cochrane Central Register of Controlled Trials; PubMed; EMBASE; CINAHL......; Web of Science; CAB Abstracts; ISRCTN and additional sources for published and unpublished trials. The date of the search was 24 July 2014. SELECTION CRITERIA: Randomised controlled trials (RCTs) exploring the efficacy of stereotactic radiotherapy compared with observation alone, microsurgical...

  1. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    Energy Technology Data Exchange (ETDEWEB)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa [Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); Department of Neurosurgery, Division of Radiotherapy, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy); CyberKnife Centre, Centro Diagnostico Italiano, 20147 Milano (Italy); Division of Medical Physics, Fondazione IRCCS, Istituto S. Raffaele, 20132 Milano (Italy); Department of Neurosurgery, Division of Medical Physics, Fondazione IRCCS, Istituto Neurologico C. Besta, 20133 Milano (Italy)

    2010-07-15

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  2. Evaluation of the peripheral dose in stereotactic radiotherapy and radiosurgery treatments

    International Nuclear Information System (INIS)

    Di Betta, Erika; Fariselli, Laura; Bergantin, Achille; Locatelli, Federica; Del Vecchio, Antonella; Broggi, Sara; Fumagalli, Maria Luisa

    2010-01-01

    Purpose: The main purpose of this work was to compare peripheral doses absorbed during stereotactic treatment of a brain lesion delivered using different devices. These data were used to estimate the risk of stochastic effects. Methods: Treatment plans were created for an anthropomorphic phantom and delivered using a LINAC with stereotactic cones and a multileaf collimator, a CyberKnife system (before and after a supplemental shielding was applied), a TomoTherapy system, and a Gamma Knife unit. For each treatment, 5 Gy were prescribed to the target. Measurements were performed with thermoluminescent dosimeters inserted roughly in the position of the thyroid, sternum, upper lung, lower lung, and gonads. Results: Mean doses ranged from of 4.1 (Gamma Knife) to 62.8 mGy (LINAC with cones) in the thyroid, from 2.3 (TomoTherapy) to 30 mGy (preshielding CyberKnife) in the sternum, from 1.7 (TomoTherapy) to 20 mGy (preshielding CyberKnife) in the upper part of the lungs, from 0.98 (Gamma Knife) to 15 mGy (preshielding CyberKnife) in the lower part of the lungs, and between 0.3 (Gamma Knife) and 10 mGy (preshielding CyberKnife) in the gonads. Conclusions: The peripheral dose absorbed in the sites of interest with a 5 Gy fraction is low. Although the risk of adverse side effects calculated for 20 Gy delivered in 5 Gy fractions is negligible, in the interest of optimum patient radioprotection, further studies are needed to determine the weight of each contributor to the peripheral dose.

  3. SU-E-T-642: Safety Procedures for Error Elimination in Cyberknife Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiation Therapy (SBRT)

    International Nuclear Information System (INIS)

    Hussain, A; Alkafi, A; Al-Najjar, W; Moftah, B

    2014-01-01

    Purpose: Cyberknife system is used for providing stereotactic radiosurgery (SRS) and stereotactic body radiation therapy (SBRT) hypofractionation scheme. The whole treatment delivery is based on live imaging of the patient. The minor error made at any stage may bring severe radiation injury to the patient or damage to the system itself. Several safety measures were taken to make the system safer. Methods: The radiation treatment provided thru a 6MV linac attached to Kuka robot (Cyberknife G4, Accuray Inc. Sunnyvale, CA, USA). Several possible errors were identified related to patient alignment, treatment planning, dose delivery and physics quality assurance. During dose delivery, manual and visual checks were introduced to confirm pre and intra-treatment imaging to reduce possible errors. One additional step was introduced to confirm that software tracking-tools had worked correctly with highest possible confidence level. Robotic head move in different orientations over and around the patient body, the rigidity of linac-head cover and other accessories was checked periodically. The vender was alerted when a tiny or bigger piece of equipment needed additional interlocked support. Results: As of our experience treating 525 patients on Cyberknife during the last four years, we saw on and off technical issues. During image acquisition, it was made essential to follow the site-specific imaging protocols. Adequate anatomy was contoured to document the respective doses. Followed by auto-segmentation, manual tweaking was performed on every structure. The calculation box was enclosing the whole image during the final calculation. Every plan was evaluated on slice-by slice basis. To review the whole process, a check list was maintained during the physics 2nd-check. Conclusion: The implementation of manual and visual additional checks introduced along with automated checks for confirmation was found promising in terms of reduction in systematic errors and making the system

  4. Dosimetry comparison of irradiation with conformal radiotherapy, intensity modulated radiotherapy, conformal radiotherapy in stereotactic conditions and robotic stereotactic radiotherapy for benign brain tumours

    International Nuclear Information System (INIS)

    Spasic, E.; Noel, A.; Buchheit, I.; Bernier, V.

    2011-01-01

    Purpose. - To compare several techniques in order to determine the best treatment for benign brain tumours. Methods and patients. - A retrospective study was performed for five patients who received 3D-conformal radiotherapy, intensity modulated radiotherapy or CyberKnife R . These patients had a meningioma, a pituitary tumour, a cranio-pharyngioma or a neurinoma. In each case, these treatment plans were optimised and compared with the three other dosimetries. Radiobiological or positioning parameters were evaluated, as well as dosimetric parameters, in order to compare treatments with different characteristics. Results. - The dosimetric parameters showed that the choice of treatment seemed to be determined mostly by tumour size, shape and proximity with organs at risk (not tumour localisation). Whereas the results showed no significant deviations with regards to the radiobiological parameters. Therefore, with these parameters, it was difficult to give priority to a treatment. Conclusions. - With regards to benign brain tumours of medium or large size, intensity modulated radiotherapy seemed the recommended treatment. It enabled to obtain a good ratio between efficacy and toxicity for tumours that are really close to organs at risk. Concerning small benign brain tumours, the CyberKnife R was probably the best treatment. (authors)

  5. Hypofractionated stereotactic body radiotherapy in low- and intermediate-risk prostate carcinoma

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hun Jung; Phak, Jeong Hoon; Kim, Woo Chul [Dept. of Radiation Oncology, Inha University Hospital, Inha University School of Medicine, Incheon (Korea, Republic of)

    2016-12-15

    Stereotactic body radiotherapy (SBRT) takes advantage of low α/β ratio of prostate cancer to deliver a large dose in few fractions. We examined clinical outcomes of SBRT using CyberKnife for the treatment of low- and intermediate-risk prostate cancer. This study was based on a retrospective analysis of the 33 patients treated with SBRT using CyberKnife for localized prostate cancer (27.3% in low-risk and 72.7% in intermediate-risk). Total dose of 36.25 Gy in 5 fractions of 7.25 Gy were administered. The acute and late toxicities were recorded using the Radiation Therapy Oncology Group scale. Prostate-specific antigen (PSA) response was monitored. Thirty-three patients with a median 51 months (range, 6 to 71 months) follow-up were analyzed. There was no biochemical failure. Median PSA nadir was 0.27 ng/mL at median 33 months and PSA bounce occurred in 30.3% (n = 10) of patients at median at median 10.5 months after SBRT. No grade 3 acute toxicity was noted. The 18.2% of the patients had acute grade 2 genitourinary (GU) toxicities and 21.2% had acute grade 2 gastrointestinal (GI) toxicities. After follow-up of 2 months, most complications had returned to baseline. There was no grade 3 late GU and GI toxicity. Our experience with SBRT using CyberKnife in low- and intermediate-risk prostate cancer demonstrates favorable efficacy and toxicity. Further studies with more patients and longer follow-up duration are required.

  6. Visual Outcome in Meningiomas Around Anterior Visual Pathways Treated With Linear Accelerator Fractionated Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Stiebel-Kalish, Hadas; Reich, Ehud; Gal, Lior; Rappaport, Zvi Harry; Nissim, Ouzi; Pfeffer, Raphael; Spiegelmann, Roberto

    2012-01-01

    Purpose: Meningiomas threatening the anterior visual pathways (AVPs) and not amenable for surgery are currently treated with multisession stereotactic radiotherapy. Stereotactic radiotherapy is available with a number of devices. The most ubiquitous include the gamma knife, CyberKnife, tomotherapy, and isocentric linear accelerator systems. The purpose of our study was to describe a case series of AVP meningiomas treated with linear accelerator fractionated stereotactic radiotherapy (FSRT) using the multiple, noncoplanar, dynamic conformal rotation paradigm and to compare the success and complication rates with those reported for other techniques. Patients and Methods: We included all patients with AVP meningiomas followed up at our neuro-ophthalmology unit for a minimum of 12 months after FSRT. We compared the details of the neuro-ophthalmologic examinations and tumor size before and after FSRT and at the end of follow-up. Results: Of 87 patients with AVP meningiomas, 17 had been referred for FSRT. Of the 17 patients, 16 completed >12 months of follow-up (mean 39). Of the 16 patients, 11 had undergone surgery before FSRT and 5 had undergone FSRT as first-line management. Tumor control was achieved in 14 of the 16 patients, with three meningiomas shrinking in size after RT. Two meningiomas progressed, one in an area that was outside the radiation field. The visual function had improved in 6 or stabilized in 8 of the 16 patients (88%) and worsened in 2 (12%). Conclusions: Linear accelerator fractionated RT using the multiple noncoplanar dynamic rotation conformal paradigm can be offered to patients with meningiomas that threaten the anterior visual pathways as an adjunct to surgery or as first-line treatment, with results comparable to those reported for other stereotactic RT techniques.

  7. Stereotactic intracranial radiotherapy: Dose prescription

    International Nuclear Information System (INIS)

    Schlienger, M.; Lartigau, E.; Nataf, F.; Mornex, F.; Latorzeff, I.; Lisbona, A.; Mahe, M.

    2012-01-01

    The aim of this article was the study of the successive steps permitting the prescription of dose in stereotactic intracranial radiotherapy, which includes radiosurgery and fractionated stereotactic radiotherapy. The successive steps studied are: the choice of stereotactic intracranial radiotherapy among the therapeutic options, based on curative or palliative treatment intent, then the selection of lesions according to size/volume, pathological type and their number permitting the choice between radiosurgery or fractionated stereotactic radiotherapy, which have the same methodological basis. Clinical experience has determined the level of dose to treat the lesions and limit the irradiation of healthy adjacent tissues and organs at risk structures. The last step is the optimization of the different parameters to obtain a safe compromise between the lesion dose and healthy adjacent structures. Study of dose-volume histograms, coverage indices and 3D imaging permit the optimization of irradiation. For lesions close to or included in a critical area, the prescribed dose is planned using the inverse planing method. Implementation of the successively described steps is mandatory to insure the prescription of an optimized dose. The whole procedure is based on the delineation of the lesion and adjacent healthy tissues. There are sometimes difficulties to assess the delineation and the volume of the target, however improvement of local control rates and reduction of secondary effects are the proof that the totality of the successive procedures are progressively improved. In practice, stereotactic intracranial radiotherapy is a continually improved treatment method, which constantly benefits from improvements in the choice of indications, imaging, techniques of irradiation, planing/optimization methodology and irradiation technique and from data collected from prolonged follow-up. (authors)

  8. CyberKnife robotic image-guided stereotactic radiotherapy for oligometastic cancer. A prospective evaluation of 95 patients/118 lesions

    Energy Technology Data Exchange (ETDEWEB)

    Jereczek-Fossa, B.A.; Bossi-Zanetti, I.; Mauro, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Milan Univ. (Italy); Beltramo, G.; Bianchi, L.C. [CyberKnife Center CDI, Milan (Italy); Fariselli, L. [Carlo Besta Neurological Institute Foundation, Milan (Italy). Radiotherapy Unit; Fodor, C. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; Fossati, P.; Orecchia, R. [European Institute of Oncology, Milan (Italy). Dept. of Radiotherapy; National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Milan Univ. (Italy); Baroni, G. [National Center for Oncological Hadrontherapy (CNAO) Foundation, Pavia, Milan (Italy); Politecnico di Milano (Italy). Dept. of Bioengineering

    2013-06-15

    Purpose: To evaluate the outcome of robotic CyberKnife (Accuray Inc. Sunnyvale, USA)-based stereotactic radiotherapy (CBK-SRT) for oligometastic cancer patients. Patients and methods: Between May 2007 and December 2009, 95 patients with a total of 118 lesions underwent CBK-SRT (median dose 24 Gy in 3 fractions). Inclusion criteria: adult patients with limited volume cancer; suitability for SRT but not for other local therapies. Primary diagnoses included breast, lung, head and neck, gastrointestinal and other malignancies. Prostate cancer patients were excluded. Concomitant systemic therapy was given in 40 % of cases and median follow-up was 12 months. Toxicity and tumor response were evaluated using the Radiation Therapy Oncology Group/European Organization for Research and Treatment of Cancer (RTOG/EORTC) Scale and Response Evaluation Criteria in Solid Tumors RECIST. Results: Toxicity was rare and observed mainly in patients with comorbidities or uncontrolled cancer. Out of 87 evaluable lesions, complete radiological response, partial response, stabilization and progressive disease were observed in 15 (17 %), 25 (29 %), 34 (39 %) and 13 (15 %) lesions, respectively. Upon restricting the analysis to lesions treated with CBK-SRT alone (no concomitant therapy), response- and local control (LC) rates remained similar. Actuarial 3-year in-field progression-free survival- (i.e. LC), progression-free survival- (PFS) and overall-survival (OS) rates were 67.6, 18.4, and 31.2 %, respectively. LC was reduced in cases of early recurrence. OS- and cause-specific survival (CSS) rates were significantly lower in patients treated for visceral lesions. Failures were predominantly out-field. Conclusion: CBK-SRT is a feasible therapeutic approach for oligometastastic cancer patients that provides long-term in-field tumor control with a low toxicity profile. Further investigations should focus on dose escalation and optimization of the combination with systemic therapies. (orig.)

  9. Six-dimensional correction of intra-fractional prostate motion with CyberKnife stereotactic body radiation therapy

    Directory of Open Access Journals (Sweden)

    Sean eCollins

    2011-12-01

    Full Text Available AbstractLarge fraction radiation therapy offers a shorter course of treatment and radiobiological advantages for prostate cancer treatment. The CyberKnife is an attractive technology for delivering large fraction doses based on the ability to deliver highly conformal radiation therapy to moving targets. In addition to intra-fractional translational motion (left-right, superior-inferior and anterior-posterior, prostate rotation (pitch, roll and yaw can increase geographical miss risk. We describe our experience with six-dimensional (6D intrafraction prostate motion correction using CyberKnife stereotactic body radiation therapy (SBRT. Eighty-eight patients were treated by SBRT alone or with supplemental external radiation therapy. Trans-perineal placement of four gold fiducials within the prostate accommodated X-ray guided prostate localization and beam adjustment. Fiducial separation and non-overlapping positioning permitted the orthogonal imaging required for 6D tracking. Fiducial placement accuracy was assessed using the CyberKnife fiducial extraction algorithm. Acute toxicities were assessed using Common Toxicity Criteria (CTC v3. There were no Grade 3, or higher, complications and acute morbidity was minimal. Ninety-eight percent of patients completed treatment employing 6D prostate motion tracking with intrafractional beam correction. Suboptimal fiducial placement limited treatment to 3D tracking in 2 patients. Our experience may guide others in performing 6D correction of prostate motion with CyberKnife SBRT.

  10. Stereotactic Radiosurgery (SRS) / Stereotactic body radiotherapy (SBRT): Benefit to Irish patients and Irish Healthcare Economy

    LENUS (Irish Health Repository)

    Cagney, DN

    2017-01-01

    Cancer incidence across Europe is projected to rise rapidly over the next decade. This rising cancer incidence is mirrored by increasing use of and indications for stereotactic radiation. This paper seeks to summarize the exponential increase in indications for stereotactic radiotherapy as well as the evolving economic advantages of stereotactic radiosurgery and stereotactic body radiotherapy

  11. Dose linearity and monitor unit stability of a G4 type cyberknife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Sudahar, H.; Kurup, P.G.G.; Murali, V.; Velmurugan, J.

    2012-01-01

    Dose linearity studies on conventional linear accelerators show a linearity error at low monitor units (MUs). The purpose of this study was to establish the dose linearity and MU stability characteristics of a cyberknife (Accuracy Inc., USA) stereotactic radiosurgery system. Measurements were done at a depth of 5 cm in a stereotactic dose verification phantom with a source to surface distance of 75 cm in a Generation 4 (G4) type cyberknife system. All the 12 fixed-type collimators starting from 5 to 60 mm were used for the dose linearity study. The dose linearity was examined in small (1-10), medium (15-100) and large (125-1000) MU ranges. The MU stability test was performed with 60 mm collimator for 10 MU and 20 MU with different combinations. The maximum dose linearity error of -38.8% was observed for 1 MU with 5 mm collimator. Dose linearity error in the small MU range was considerably higher than in the medium and large MU ranges. The maximum error in the medium range was -2.4%. In the large MU range, the linearity error varied between -0.7% and 1.2%. The maximum deviation in the MU stability was -3.03%. (author)

  12. Linac based radiosurgery and stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Mackie, T.R.

    2008-01-01

    The following topics were discussed: Definition of stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Stereo market; Indications for SRS/SRT; History of linac-based SRS/SRT; Variety of systems; QA for SRS; Localization; and Imaging. (P.A.)

  13. Stereotactic radiotherapy for pediatric intracranial germ cell tumors

    International Nuclear Information System (INIS)

    Zissiadis, Yvonne; Dutton, Sharon; Kieran, Mark; Goumnerova, Liliana; Scott, R. Michael; Kooy, Hanne M.; Tarbell, Nancy J.

    2001-01-01

    Purpose: Intracranial germ cell tumors are rare, radiosensitive tumors seen most commonly in the second and third decades of life. Radiotherapy alone has been the primary treatment modality for germinomas, and is used with chemotherapy for nongerminomatous tumors. Stereotactic radiotherapy techniques minimize the volume of surrounding normal tissue irradiated and, hence, the late radiation morbidity. This study reports our experience with stereotactic radiotherapy in this group of tumors. Methods and Materials: Between December 1992 and December 1998, 18 patients with intracranial germ cell tumors were treated with stereotactic radiotherapy. A total of 23 histologically proven tumors were treated. Thirteen patients had a histologic diagnosis of germinoma, and 5 patients had germinoma with nongerminomatous elements. Of those patients with a histologic diagnosis of germinoma, 5 had multiple midline tumors. The median age of the patients was 12.9 years (range, 5.6-17.5 years). Results: A boost using stereotactic radiotherapy was delivered to 19 tumors following whole-brain radiation in 8 cases and craniospinal radiation in 11 cases. Three tumors were treated with stereotactic radiotherapy to the tumor volume alone following chemotherapy, and 1 tumor received a boost using stereotactic radiosurgery following craniospinal radiation. A median dose of 2520 cGy (range, 1500-3600) cGy was given to the whole brain, and a median dose of 2160 (range, 2100-2600) cGy was given to the spinal field. The median boost dose to the tumor was 2600 (range, 2160-3600) cGy, given by stereotactic radiotherapy delivered to the 95% isodose line. At a median follow-up time of 40 (range, 12-73) months, no local or marginal recurrences were reported in patients with germinoma. Two patients with nongerminomatous tumors have relapsed. One had elevation of tumor markers only at 37 months following treatment, and the other had persistent disease following chemotherapy and radiation therapy. Eight

  14. Hypofractionated stereotactic irradiation. Basic and clinical researches

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Iwata, Hiromitsu; Otsuka, Shinya; Ogino, Hiroyuki; Ayakawa, Shiho

    2011-01-01

    Hypofractionated stereotactic radiotherapy (SRT) has a number of biological advantages over single-session radiosurgery. An apparent trend is seen in the clinic towards shift from the latter to the former; however, there is no adequate model to convert single doses to hypofractionated doses. The linear-quadratic model overestimates the effect of single-fraction radiation. This should be kept in mind in evaluating the doses of stereotactic irradiation. ''Biological effective dose'' should not be used in radiosurgery and hypofractionated SRT. Clinically, we have used 3- to 10-fraction SRT for acoustic neuroma and benign skull base tumors using cyberknife and tomotherapy. Preliminary results are encouraging. (author)

  15. Salvage Reirradiaton With Stereotactic Body Radiotherapy for Locally Recurrent Head-and-Neck Tumors

    International Nuclear Information System (INIS)

    Cengiz, Mustafa; Ozyigit, Goekhan; Yazici, Goezde; Dogan, Ali; Yildiz, Ferah; Zorlu, Faruk; Guerkaynak, Murat; Gullu, Ibrahim H.; Hosal, Sefik; Akyol, Fadil

    2011-01-01

    Purpose: In this study, we present our results of reirradiation of locally recurrent head-and-neck cancer with image-guided, fractionated, frameless stereotactic body radiotherapy technique. Methods and Materials: From July 2007 to February 2009, 46 patients were treated using the CyberKnife (Accuray, Sunnyvale, CA) at the Department of Radiation Oncology, Hacettepe University, Ankara, Turkey. All patients had recurrent, unresectable, and previously irradiated head-and-neck cancer. The most prominent site was the nasopharynx (32.6%), and the most common histopathology was epidermoid carcinoma. The planning target volume was defined as the gross tumor volume identified on magnetic resonance imaging and computed tomography. There were 22 female and 24 male patients. Median age was 53 years (range, 19-87 years). The median tumor dose with stereotactic body radiotherapy was 30 Gy (range, 18-35 Gy) in a median of five (range, one to five) fractions. Results: Of 37 patients whose response to therapy was evaluated, 10 patients (27%) had complete tumor regression, 11 (29.8%) had partial response, and 10 (27%) had stable disease. Ultimate local disease control was achieved in 31 patients (83.8%). The overall survival was 11.93 months in median (ranged, 11.4 - 17.4 months), and the median progression free survival was 10.5 months. One-year progression-free survival and overall survival were 41% and 46%, respectively. Grade II or greater long-term complications were observed in 6 (13.3%) patients. On follow-up, 8 (17.3%) patients had carotid blow-out syndrome, and 7 (15.2%) patients died of bleeding from carotid arteries. We discovered that this fatal syndrome occurred only in patients with tumor surrounding carotid arteries and carotid arteries receiving all prescribed dose. Conclusions: Stereotactic body radiotherapy is an appealing treatment option for patients with recurrent head-and-neck cancer previously treated with radiation to high doses. Good local control with

  16. Gemcitabine Chemotherapy and Single-Fraction Stereotactic Body Radiotherapy for Locally Advanced Pancreatic Cancer

    International Nuclear Information System (INIS)

    Schellenberg, Devin; Goodman, Karyn A.; Lee, Florence; Chang, Stephanie; Kuo, Timothy; Ford, James M.; Fisher, George A.; Quon, Andrew; Desser, Terry S.; Norton, Jeffrey; Greco, Ralph; Yang, George P.; Koong, Albert C.

    2008-01-01

    Purpose: Fractionated radiotherapy and chemotherapy for locally advanced pancreatic cancer achieves only modest local control. This prospective trial evaluated the efficacy of a single fraction of 25 Gy stereotactic body radiotherapy (SBRT) delivered between Cycle 1 and 2 of gemcitabine chemotherapy. Methods and Materials: A total of 16 patients with locally advanced, nonmetastatic, pancreatic adenocarcinoma received gemcitabine with SBRT delivered 2 weeks after completion of the first cycle. Gemcitabine was resumed 2 weeks after SBRT and was continued until progression or dose-limiting toxicity. The gross tumor volume, with a 2-3-mm margin, was treated in a single 25-Gy fraction by Cyberknife. Patients were evaluated at 4-6 weeks, 10-12 weeks, and every 3 months after SBRT. Results: All 16 patients completed SBRT. A median of four cycles (range one to nine) of chemotherapy was delivered. Three patients (19%) developed local disease progression at 14, 16, and 21 months after SBRT. The median survival was 11.4 months, with 50% of patients alive at 1 year. Patients with normal carbohydrate antigen (CA)19-9 levels either at diagnosis or after Cyberknife SBRT had longer survival (p <0.01). Acute gastrointestinal toxicity was mild, with 2 cases of Grade 2 (13%) and 1 of Grade 3 (6%) toxicity. Late gastrointestinal toxicity was more common, with five ulcers (Grade 2), one duodenal stenosis (Grade 3), and one duodenal perforation (Grade 4). A trend toward increased duodenal volumes radiated was observed in those experiencing late effects (p = 0.13). Conclusion: SBRT with gemcitabine resulted in comparable survival to conventional chemoradiotherapy and good local control. However, the rate of duodenal ulcer development was significant

  17. A phase I/II study on stereotactic body radiotherapy with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm for lung tumors.

    Science.gov (United States)

    Iwata, Hiromitsu; Ishikura, Satoshi; Murai, Taro; Iwabuchi, Michio; Inoue, Mitsuhiro; Tatewaki, Koshi; Ohta, Seiji; Yokota, Naoki; Shibamoto, Yuta

    2017-08-01

    In this phase I/II study, we assessed the safety and initial efficacy of stereotactic body radiotherapy (SBRT) for lung tumors with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm. Study subjects had histologically confirmed primary non-small-cell lung cancer staged as T1a-T2aN0M0 and pulmonary oligometastasis. The primary endpoint was the incidence of Grade ≥3 radiation pneumonitis (RP) within 180 days of the start of SBRT. The secondary endpoint was local control and overall survival rates. Five patients were initially enrolled at level 1 [50 Gy/4 fractions (Fr)]; during the observation period, level 0 (45 Gy/4 Fr) was opened. The dose was escalated to the next level when grade ≥3 RP was observed in 0 out of 5 or 1 out of 10 patients. Virtual quality assurance planning was performed for 60 Gy/4 Fr; however, dose constraints for the organs at risk did not appear to be within acceptable ranges. Therefore, level 2 (55 Gy/4 Fr) was regarded as the upper limit. After the recommended dose (RD) was established, 15 additional patients were enrolled at the RD. The prescribed dose was normalized at the 95% volume border of the planning target volume based on the Monte Carlo algorithm. Between September 2011 and September 2015, 40 patients (primary 30; metastasis 10) were enrolled. Five patients were enrolled at level 0, 15 at level 1, and 20 at level 2. Only one grade 3 RP was observed at level 1. Two-year local control and overall survival rates were 98 and 81%, respectively. The RD was 55 Gy/4 Fr. SBRT with real-time tumor tracking using CyberKnife based on the Monte Carlo algorithm was tolerated well and appeared to be effective for solitary lung tumors.

  18. Preliminary experience with frameless stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Buatti, John M.; Bova, Francis J.; Friedman, William A.; Meeks, Sanford L.; Marcus, Robert B.; Mickle, J. Parker; Ellis, Thomas L.; Mendenhall, William M.

    1998-01-01

    Purpose: To report initial clinical experience with a novel high-precision stereotactic radiotherapy system. Methods and Materials: Sixty patients ranging in age from 2 to 82 years received a total of 1426 treatments with the University of Florida frameless stereotactic radiotherapy system. Of the total, 39 (65%) were treated with stereotactic radiotherapy (SRT) alone, and 21 (35%) received SRT as a component of radiotherapy. Pathologic diagnoses included meningiomas (15 patients), low-grade astrocytomas (11 patients), germinomas (9 patients), and craniopharyngiomas (5 patients). The technique was used as means of dose escalation in 11 patients (18%) with aggressive tumors. Treatment reproducibility was measured by comparing bite plate positioning registered by infrared light-emitting diodes (IRLEDs) with the stereotactic radiosurgery reference system, and with measurements from each treatment arc for the 1426 daily treatments (5808 positions). We chose 0.3 mm vector translation error and 0.3 deg. rotation about each axis as the maximum tolerated misalignment before treating each arc. Results: With a mean follow-up of 11 months, 3 patients had recurrence of malignant disease. Acute side effects were minimal. Of 11 patients with low grade astrocytomas, 4 (36%) had cerebral edema and increased enhancement on MR scans in the first year, and 2 required steroids. All had resolution and marked tumor involution on follow-up imaging. Bite plate reproducibility was as follows. Translational errors: anterior-posterior, 0.01 ± 0.10; lateral, 0.02 ± 0.07; axial, 0.01 ± 0.10. Rotational errors (degrees): anterior-posterior, 0.00 ± 0.03; lateral, 0.00 ± 0.06; axial, 0.01 ± 0.04. No patient treatment was delivered beyond the maximum tolerated misalignment. Daily treatment was delivered in approximately 15 min per patient. Conclusion: Our initial experience with stereotactic radiotherapy using the infrared camera guidance system was good. Patient selection and treatment

  19. Carotid blowout syndrome in pharyngeal cancer patients treated by hypofractionated stereotactic re-irradiation using CyberKnife: A multi-institutional matched-cohort analysis

    International Nuclear Information System (INIS)

    Yamazaki, Hideya; Ogita, Mikio; Himei, Kengo; Nakamura, Satoaki; Kotsuma, Tadayuki; Yoshida, Ken; Yoshioka, Yasuo

    2015-01-01

    Background and purpose: Although reirradiation has attracted attention as a potential therapy for recurrent head and neck tumors with the advent of modern radiotherapy, severe rate toxicity such as carotid blowout syndrome (CBOS) limits its potential. The aim of this study was to identify the risk factors of CBOS after hypofractionated stereotactic radiotherapy (SBRT). Methods and patients: We conducted a matched-pair design examination of pharyngeal cancer patients treated by CyberKnife reirradiation in four institutes. Twelve cases with CBOS were observed per 60 cases without CBOS cases. Prognostic factors for CBOS were analyzed and a risk classification model was constructed. Results: The median prescribed radiation dose was 30 Gy in 5 fractions with CyberKnife SBRT after 60 Gy/30 fractions of previous radiotherapy. The median duration between reirradiation and CBOS onset was 5 months (range, 0–69 months). CBOS cases showed a median survival time of 5.5 months compared to 22.8 months for non-CBOS cases (1-year survival rate, 36% vs.72%; p = 0.003). Univariate analysis identified an angle of carotid invasion of >180°, the presence of ulceration, planning treatment volume, and irradiation to lymph node areas as statistically significant predisposing factors for CBOS. Only patients with carotid invasion of >180° developed CBOS (12/50, 24%), whereas no patient with tumor involvement less than a half semicircle around the carotid artery developed CBOS (0/22, 0%, p = 0.03). Multivariate Cox hazard model analysis revealed that the presence of ulceration and irradiation to lymph nodes were statistically significant predisposing factors. Thus, we constructed a CBOS risk classification system: CBOS index = (summation of risk factors; carotid invasion >180°, presence of ulceration, lymph node area irradiation). This system sufficiently separated the risk groups. Conclusion: The presence of ulceration and lymph node irradiation are risk factors of CBOS. The CBOS index

  20. Metallic stent and stereotactic conformal radiotherapy for hilar cholangiocarcinoma

    International Nuclear Information System (INIS)

    Li Yu; Wang Ning; Tian Qihe; Guo Zhanwen; Zhang Haibo; Song Liyan

    2005-01-01

    Objective: To evaluate the effect of metallic stent combined with stereotactic conformal radiotherapy (SCRT) for hilar cholangiocarcinoma. Methods: Fifty-four patients with hilar cholangiocarcinoma were analyzed, including 31 treated with stent plus stereotactic conformal radiotherapy (combined group) and 23 with metallic stent alone (control group). Results: The mean survival time of combined group was 11.1 ± 4.6 months, compared with 5.1 ± 2.8 months of the control group, giving a significant difference between the two groups (P<0.01). Conclusion: The combination of metallic stent and stereotactic conformal radiotherapy is more effective than metallic stent alone for unresectable hilar cholangiocarcinoma. (authors)

  1. Cyberknife: A double edged sword?

    International Nuclear Information System (INIS)

    Joseph, B.; Ramachandra, A.; Supeb, S. S.

    2010-01-01

    The Cyberknife represents a new, frame less stereotactic radiosurgery system which efficiently incorporates advance robotics with computerized image reconstruction to allow highly conformal image guided radiation delivery. This review focus is on the pros and cons of this new radiotherapy tool, its current indications, safety profile and future directions. A literature search of Medline, Pubmed, Biomed, Medscape and Cancer lit database were referred to retrieve relevant data/information. The authors conclude that the use of this system offers an invaluable solution to the treatment of selective tumours/lesions located close to critical structures, salvage of recurrent and metastatic lesions and potential of treatment of selective early stage malignancies like the carcinoma prostate and lung. However, it is still too premature, with insufficient follow up data to advocate it as the treatment of choice in any set up. There are several radiobiological issues that also remain in the grey zone. (authors)

  2. Preliminary experience with frameless stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Buatti, John M.; Bova, Frank J.; Friedman, William A.; Meeks, Sanford L.; Ellis, Thomas L.; Marcus, Robert B.; Zuofeng, Li; Mendenhall, William M.

    1997-01-01

    Purpose/Objective: To report our initial clinical experience using a novel high-precision frameless stereotactic radiotherapy system in 50 patients who have received 1271 treatments. Materials and Methods: Fifty patients ranging in age from 2 to 72 yr were treated with fractionated stereotactic radiotherapy. Thirty-two were treated with stereotactic radiotherapy alone, and 18 had stereotactic radiotherapy interdigitated as a boost in addition to standard irradiation. Pathologies treated included meningioma (13), low grade astrocytoma (10), germinoma (9), craniopharyngioma (4), schwannoma (2), and pituitary adenoma (2). Two additional patients had miscellaneous benign neoplasms and 8 patients had the technique used as a dose escalation strategy for malignant lesions including chordoma, primitive neuroectodermal tumor, sarcoma, and anaplastic oligoastrocytoma. Treatment reproducibility was initially gauged by comparing the bite plate position using infrared light emitting diodes (irleds) with the stereotactic radiosurgery reference system. This test of accuracy consisted of 10 bite plate repositionings for each patient and 100 readings of each of the 6 irleds on the bite plate at each new position. Each of the 1271 patient treatments was monitored for continuous digital position, and a reading was made before treating each arc of radiation. We chose 0.3 mm translation and 0.3 degrees rotation as the maximum tolerated misalignment before treating each arc. Results: With a mean follow-up of 9 mo, no patient had a marginal or distal failure. One patient with a malignant glioma had central disease progression. Acute side effects were minimal. In 3 of 9 low grade astrocytomas, a marked increase in imaging enhancement and edema occurred in the first year after treatment that resolved with steroids. The initial test of accuracy revealed bite plate reproducibility as follows. Translational errors (mm): Anterior-posterior, 0.06 ± 0.06; lateral, 0.03 ± 0.05; axial, 0.07 ± 0

  3. Stereotactic radiotherapy for brain metastasis

    International Nuclear Information System (INIS)

    Noel, G.; Daisne, J.F.; Thillays, F.

    2012-01-01

    Stereotactic radiosurgery is now well implanted in the radiotherapy treatment tools of brain metastasis. The dose can be delivered in one or multiple sessions. Results seem equivalent. CT scan and MRI imaging are required to delineate and calculate dosimetry. Doses are variable according to the size of the metastases, localization, pathology or equipment. Stabilization or reduction of tumour size is the rules after stereotactic treatment. Impact in terms of overall survival is more difficult to apprehend because of the general context of the disease. Many questions remain unresolved, such as the usefulness of whole brain irradiation, adaptation of the treatment schedule to tumour pathophysiology, role of stereotactic treatment after surgery of metastases, etc. (authors)

  4. Reirradiation of brain and skull base tumors with fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tokuuye, Koichi; Akine, Yasuyuki; Sumi, Minako; Kagami, Yoshikazu; Ikeda, Hiroshi; Oyama, Hiroshi; Inou, Yasushi; Shibui, Soichiro; Nomura, Kazuhiro

    1998-01-01

    Purpose: We evaluated the feasibility of fractionated stereotactic radiotherapy for small intracranial recurrences after conventional radiotherapy. Methods and Materials: Nineteen patients who had initially undergone conventional radiotherapy to intracranial lesions, receiving a median total dose of 50 Gy in 5 weeks, were retreated with stereotactic radiotherapy for their recurrences and received a median total dose of 42 Gy in seven fractions over 2.3 weeks. Results: Of the 19 patients, 15 achieved local control 3-51 months after reirradiation. No patient suffered from acute reaction, but one patient with a history of extensive radiotherapy developed progressive radionecrosis 9 months after reirradiation. Conclusions: Fractionated stereotactic radiotherapy of intracranial recurrences appears to be effective in achieving in local control with negligible morbidity. We believe it merits further investigation in a prospective study

  5. Stereotactic Radiotherapy by 6MV Linear Accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Oho, Yoon Kyeong; Kim, Mi Hee; Gil, Hak Jun [Catholic University College of Medicine, Seoul (Korea, Republic of)] (and others)

    1988-12-15

    Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4 months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngioma (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be performed safely with a radiation dose of 12-30 Gy. So this noninvasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT.

  6. Stereotactic Radiotherapy by 6MV Linear Accelerator

    International Nuclear Information System (INIS)

    Oho, Yoon Kyeong; Kim, Mi Hee; Gil, Hak Jun

    1988-01-01

    Eight patients with intracranial tumors or arteriovenous malformation (AVM)s which were less than 3 cm in diameter were treated by a technique of stereotactic radiotherapy during the 4 months period from July 1988 through October 1988 at the Division of Radiation Therapy, Kang-Nam St. Mary's Hospital, Catholic University Medical College. The patients were diagnosed as AVMs in 3 cases, acoustic neurinoma, craniopharyngioma (recurrent), hemangioblastoma, pineocytoma, and pituitary microadenoma in each case. There are several important factors in this procedure, such as localization system, portal, field size, radiation dose, and perioperative supportive care. It is suggested that stereotactic radiotherapy may be performed safely with a radiation dose of 12-30 Gy. So this noninvasive procedure can be used to treat unresectable intracranial tumors or AVMs. Of these, clinical symptoms had been regressed in AVMs in 2 cases at 3 months and 2 months after Stereotactic radiotherapy, one of whom was confirmed slightly regressed on the follow-up angiogram. And also craniopharyngioma and pineocytoma was minimally regressed on 3 month follow-up CT

  7. Fractionated stereotactic radiotherapy in patients with acromegaly: an interim single-centre audit

    DEFF Research Database (Denmark)

    Roug, Anne Stidsholt; Rasmussen, Åse Krogh; Juhler, M

    2010-01-01

    To evaluate the effect of fractionated stereotactic radiotherapy (FSRT) in acromegaly in a retrospective analysis.......To evaluate the effect of fractionated stereotactic radiotherapy (FSRT) in acromegaly in a retrospective analysis....

  8. Stereotactic body radiotherapy for liver tumors. Principles and practical guidelines of the DEGRO Working Group on Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Sterzing, Florian; Brunner, Thomas B.; Ernst, Iris; Greve, Burkhard; Baus, Wolfgang W.; Herfarth, Klaus; Guckenberger, Matthias

    2014-01-01

    This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a practical guideline for safe and effective stereotactic body radiotherapy (SBRT) of liver tumors. The literature on the clinical evidence of SBRT for both primary liver tumors and liver metastases was reviewed and analyzed focusing on both physical requirements and special biological characteristics. Recommendations were developed for patient selection, imaging, planning, treatment delivery, motion management, dose reporting, and follow-up. Radiation dose constraints to critical organs at risk are provided. SBRT is a well-established treatment option for primary and secondary liver tumors associated with low morbidity. (orig.) [de

  9. Rib fracture following stereotactic body radiotherapy: a potential pitfall.

    Science.gov (United States)

    Stanic, Sinisa; Boike, Thomas P; Rule, William G; Timmerman, Robert D

    2011-11-01

    Although the incidence of rib fractures after conventional radiotherapy is generally low (rib fractures are a relatively common complication of stereotactic body radiotherapy. For malignancy adjacent to the chest wall, the incidence of rib fractures after stereotactic body radiotherapy is as high as 10%. Unrecognized bone fractures can mimic bone metastases on bone scintigraphy, can lead to extensive workup, and can even lead to consideration of unnecessary systemic chemotherapy, as treatment decisions can be based on imaging findings alone. Nuclear medicine physicians and diagnostic radiologists should always consider rib fracture in the differential diagnosis.

  10. Stereotactic radiotherapy for wet age-related macular degeneration: current perspectives

    Directory of Open Access Journals (Sweden)

    Neffendorf JE

    2015-09-01

    Full Text Available James E Neffendorf, Timothy L Jackson Department of Ophthalmology, School of Medicine, King’s College London, London, United Kingdom Abstract: Neovascular age-related macular degeneration is a leading cause of blindness in the developed world. Currently, the treatment of choice is intravitreal injections of anti-VEGF medications. These require frequent dosing, up to monthly, and impose a substantial burden on patients and the health economy. Ionizing radiation was proposed as a possible treatment for age-related macular degeneration due to its anti-inflammatory and anti-fibrotic properties. Stereotactic radiotherapy is an outpatient-based radiotherapy platform that provides stereotactic application of low energy X-ray to the retina in three highly collimated beams that cross the inferior sclera to overlap at the macula. A randomized, double-masked, sham-controlled trial of 230 patients (INTREPID showed that a single dose of stereotactic radiotherapy significantly reduces the number of intravitreal anti-VEGF injections needed over 2 years. A larger randomized controlled trial (STAR is underway. Keywords: wet age-related macular degeneration, radiation therapy, stereotactic radiotherapy, vascular endothelial growth factor

  11. Long-Term Outcomes From a Prospective Trial of Stereotactic Body Radiotherapy for Low-Risk Prostate Cancer

    International Nuclear Information System (INIS)

    King, Christopher R.; Brooks, James D.; Gill, Harcharan; Presti, Joseph C.

    2012-01-01

    Purpose: Hypofractionated radiotherapy has an intrinsically different normal tissue and tumor radiobiology. The results of a prospective trial of stereotactic body radiotherapy (SBRT) for prostate cancer with long-term patient-reported toxicity and tumor control rates are presented. Methods and Materials: From 2003 through 2009, 67 patients with clinically localized low-risk prostate cancer were enrolled. Treatment consisted of 36.25 Gy in 5 fractions using SBRT with the CyberKnife as the delivery technology. No patient received hormone therapy. Patient self-reported bladder and rectal toxicities were graded on the Radiation Therapy Oncology Group scale (RTOG). Results: Median follow-up was 2.7 years. There were no grade 4 toxicities. Radiation Therapy Oncology Group Grade 3, 2, and 1 bladder toxicities were seen in 3% (2 patients), 5% (3 patients), and 23% (13 patients) respectively. Dysuria exacerbated by urologic instrumentation accounted for both patients with Grade 3 toxicity. Urinary incontinence, complete obstruction, or persistent hematuria was not observed. Rectal Grade 3, 2, and 1 toxicities were seen in 0, 2% (1 patient), and 12.5% (7 patients), respectively. Persistent rectal bleeding was not observed. Low-grade toxicities were substantially less frequent with QOD vs. QD dose regimen (p = 0.001 for gastrointestinal and p = 0.007 for genitourinary). There were two prostate-specific antigen (PSA), biopsy-proven failures with negative metastatic workup. Median PSA at follow-up was 0.5 ± 0.72 ng/mL. The 4-year Kaplan-Meier PSA relapse-free survival was 94% (95% confidence interval, 85%–102%). Conclusion: Significant late bladder and rectal toxicities from SBRT for prostate cancer are infrequent. PSA relapse-free survival compares favorably with other definitive treatments. The current evidence supports consideration of stereotactic body radiotherapy among the therapeutic options for localized prostate cancer.

  12. Long-Term Outcomes From a Prospective Trial of Stereotactic Body Radiotherapy for Low-Risk Prostate Cancer

    Energy Technology Data Exchange (ETDEWEB)

    King, Christopher R., E-mail: crking@mednet.ucla.edu [Departments of Radiation Oncology and Urology, University of California Los Angeles School of Medicine, Los Angeles, CA (United States); Brooks, James D.; Gill, Harcharan; Presti, Joseph C. [Department of Urology, Stanford University School of Medicine, Stanford, CA (United States)

    2012-02-01

    Purpose: Hypofractionated radiotherapy has an intrinsically different normal tissue and tumor radiobiology. The results of a prospective trial of stereotactic body radiotherapy (SBRT) for prostate cancer with long-term patient-reported toxicity and tumor control rates are presented. Methods and Materials: From 2003 through 2009, 67 patients with clinically localized low-risk prostate cancer were enrolled. Treatment consisted of 36.25 Gy in 5 fractions using SBRT with the CyberKnife as the delivery technology. No patient received hormone therapy. Patient self-reported bladder and rectal toxicities were graded on the Radiation Therapy Oncology Group scale (RTOG). Results: Median follow-up was 2.7 years. There were no grade 4 toxicities. Radiation Therapy Oncology Group Grade 3, 2, and 1 bladder toxicities were seen in 3% (2 patients), 5% (3 patients), and 23% (13 patients) respectively. Dysuria exacerbated by urologic instrumentation accounted for both patients with Grade 3 toxicity. Urinary incontinence, complete obstruction, or persistent hematuria was not observed. Rectal Grade 3, 2, and 1 toxicities were seen in 0, 2% (1 patient), and 12.5% (7 patients), respectively. Persistent rectal bleeding was not observed. Low-grade toxicities were substantially less frequent with QOD vs. QD dose regimen (p = 0.001 for gastrointestinal and p = 0.007 for genitourinary). There were two prostate-specific antigen (PSA), biopsy-proven failures with negative metastatic workup. Median PSA at follow-up was 0.5 {+-} 0.72 ng/mL. The 4-year Kaplan-Meier PSA relapse-free survival was 94% (95% confidence interval, 85%-102%). Conclusion: Significant late bladder and rectal toxicities from SBRT for prostate cancer are infrequent. PSA relapse-free survival compares favorably with other definitive treatments. The current evidence supports consideration of stereotactic body radiotherapy among the therapeutic options for localized prostate cancer.

  13. Stereotactic Radiosurgery and Hypofractionated Radiotherapy for Glioblastoma.

    Science.gov (United States)

    Shah, Jennifer L; Li, Gordon; Shaffer, Jenny L; Azoulay, Melissa I; Gibbs, Iris C; Nagpal, Seema; Soltys, Scott G

    2018-01-01

    Glioblastoma is the most common primary brain tumor in adults. Standard therapy depends on patient age and performance status but principally involves surgical resection followed by a 6-wk course of radiation therapy given concurrently with temozolomide chemotherapy. Despite such treatment, prognosis remains poor, with a median survival of 16 mo. Challenges in achieving local control, maintaining quality of life, and limiting toxicity plague treatment strategies for this disease. Radiotherapy dose intensification through hypofractionation and stereotactic radiosurgery is a promising strategy that has been explored to meet these challenges. We review the use of hypofractionated radiotherapy and stereotactic radiosurgery for patients with newly diagnosed and recurrent glioblastoma. Copyright © 2017 by the Congress of Neurological Surgeons.

  14. Stereotactic Accelerated Partial Breast Irradiation (SAPBI for Early Stage Breast Cancer: Rationale, Feasibility and Early Experience using the CyberKnife Radiosurgery Delivery Platform

    Directory of Open Access Journals (Sweden)

    Olusola eOBAYOMI-DAVIES

    2016-05-01

    Full Text Available Purpose: The efficacy of accelerated partial breast irradiation (APBI utilizing brachytherapy or conventional external beam radiation has been studied in early stage breast cancer treated with breast conserving surgery. Data regarding stereotactic treatment approaches are emerging. The CyberKnife linear accelerator enables excellent dose conformality to target structures while adjusting for target and patient motion. We report our institutional experience on the technical feasibility and rationale for SAPBI delivery using the CyberKnife radiosurgery system.Methods: Ten patients completed CyberKnife SAPBI in 2013 at Georgetown University Hospital. Four gold fiducials were implanted around the lumpectomy cavity prior to treatment under ultrasound guidance. The synchrony system tracked intrafraction motion of the fiducials. The clinical target volume (CTV was defined on contrast enhanced CT scans using surgical clips and post-operative changes. A 5 mm expansion was added to create the planning treatment volume (PTV. A total dose of 30 Gy was delivered to the PTV in 5 consecutive fractions. Target and critical structure doses were assessed as per the National Surgical Adjuvant Breast and Bowel Project B-39 study.Results: At least 3 fiducials were tracked in 100% of cases. The Mean treated PTV was 70 cm3 and the mean prescription isodose line was 80%. Mean dose to target volumes and constraints are as follows: 100% of the PTV received the prescription dose (PTV30. The volume of the ipsilateral breast receiving 30 Gy (V30 and above 15 Gy (V>15 was 14% and 31% respectively. The ipsilateral lung volume receiving 9 Gy (V9 was 3% and the contralateral lung volume receiving 1.5 Gy (V1.5 was 8%. For left sided breast cancers, the volume of heart receiving 1.5 Gy (V1.5 was 31%. Maximum skin dose was 36 Gy. At a median follow up of 1.3 years, all patients have experienced excellent/good breast cosmesis outcomes, and no breast events have been recorded

  15. Stereotactic body radiotherapy for primary prostate cancer: a systematic review

    International Nuclear Information System (INIS)

    Tan, Tze-Jian; Foroudi, Farsgad; Gill, Suki; Siva, Shankar

    2014-01-01

    Stereotactic body radiotherapy (SBRT) for prostate cancer allows overall treatment times to be reduced to as little as 1 week while maintaining a non-invasive approach. This study provides a comprehensive summary of the literature relating to SBRT in prostate cancer. A systematic review of the relevant literature was performed using structured search terms. Fourteen phase I–II trials and retrospective studies using SBRT for the treatment of prostate cancer were used. Three studies were identified which addressed cost. Dose fractionation, radiotherapy procedures, biochemical progression-free survival, toxicity, cost and quality of life were critically appraised. A total of 1472 patients were examined across studies. Median follow-up ranged from 11 to 60 months. The most common dose fractionation was 35–36.25Gy in five fractions, used in nine out of 14 studies. Ten of 14 studies used CyberKnife. The overall biochemical progression-free survival ranged 81–100%. Acute grade 2 urinary and rectal toxicities were reported in 5–42% and 0–27% of patients, respectively. Acute grade 3 or more urinary and rectal toxicity were 0.5% and 0%, respectively. Late grade 2 urinary toxicity was reported in 0–29% of patients, while 1.3% had a late grade 3 urinary toxicity. There were no late grade 4 urinary toxicities seen. Late grade 2 rectal toxicity was reported in 0–11%, while 0.5% had a late grade 3 rectal toxicity. Late grade 4 rectal toxicity was reported in 0.2% of patients.

  16. Stereotactic body radiotherapy a practical guide

    CERN Document Server

    Gaya, Andrew

    2015-01-01

    Collecting the key information in this burgeoning field into a single volume, this handbook for clinical oncology trainees and consultants covers all of the basic aspects of stereotactic radiotherapy systems and treatment and includes plenty of case studies.

  17. A case study of the neuropsychological outcomes following microsurgery, conventional radiotherapy and stereotactic radiotherapy for an adult's recurrent craniopharyngioma.

    Science.gov (United States)

    Preece, David; Allan, Alfred; Becerra, Rodrigo

    2016-01-01

    To examine the neuropsychological outcomes for an adult patient, 2 years after receiving microsurgery and conventional radiotherapy for a recurrent craniopharyngioma; and the impact of a further intervention, stereotactic radiotherapy, on this level of neuropsychological functioning. JD, a 30 year old male whose recurrent craniopharyngioma had 2 years earlier been treated with two operations and conventional radiotherapy. JD was assessed (using standardized clinical tests) before and after a course of stereotactic radiotherapy. Prior to stereotactic radiotherapy (and 2 years after microsurgery and conventional radiotherapy) JD's IQ was intact, but considerable impairments were present in executive functioning, memory, theory of mind and processing speed. Fifteen months after stereotactic radiotherapy, all neuropsychological domains remained largely static or improved, supporting the utility of this treatment option in the neuropsychological domain. However, deficits in executive functioning, memory and processing speed remained. These findings suggest that, even after multiple treatments, substantial cognitive impairments can be present in an adult patient with a recurrent craniopharyngioma. This profile of deficits underlines the inadequacy of relying purely on IQ as a marker for cognitive health in this population and emphasizes the need to include neuropsychological impairments as a focus of rehabilitation with these patients.

  18. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    International Nuclear Information System (INIS)

    Kim, Haksoo; Welford, Scott; Fabien, Jeffrey; Zheng, Yiran; Yuan, Jake; Brindle, James; Yao, Min; Lo, Simon; Wessels, Barry; Machtay, Mitchell; Sohn, Jason W.; Sloan, Andrew

    2014-01-01

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm). A

  19. Multimedia educational services in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Bazioglou, M.; Theodorou, K.; Kappas, C.

    1999-01-01

    The computer-based learning methods in medicine have been well established as stand-alone learning systems. Recently, these systems were enriched with the use of telematics technology to provide distance learning capabilities. Stereotactic radiotherapy is more of the most representative advanced radiotherapy techniques. Due to the multidisciplinary character of the technique and the rapid evolution of technology implemented, the demands in training have increased. The potential of interactive multimedia and Internet technologies for the achievement of distance learning capabilities in this domain are investigated. The realization of a computer-based educational program in stereotactic radiotherapy in a multimedia format is a new application in the computer-aided distance learning field. The system is built according to a client and server architecture, based on the Internet infrastructure, and composed of server nodes. The impact of the system may be described in terms of: time and transportation costs saving, flexibility in training (scheduling, rate and subject selection), online communication and interaction with experts, cost effective access to material (delivery or access by a large number of users and revision of the material by avoiding and database development. (authors)

  20. Stereotactic body radiotherapy for low-risk prostate cancer: five-year outcomes

    Directory of Open Access Journals (Sweden)

    King Christopher R

    2011-01-01

    Full Text Available Abstract Purpose Hypofractionated, stereotactic body radiotherapy (SBRT is an emerging treatment approach for prostate cancer. We present the outcomes for low-risk prostate cancer patients with a median follow-up of 5 years after SBRT. Method and Materials Between Dec. 2003 and Dec. 2005, a pooled cohort of 41 consecutive patients from Stanford, CA and Naples, FL received SBRT with CyberKnife for clinically localized, low-risk prostate cancer. Prescribed dose was 35-36.25 Gy in five fractions. No patient received hormone therapy. Kaplan-Meier biochemical progression-free survival (defined using the Phoenix method and RTOG toxicity outcomes were assessed. Results At a median follow-up of 5 years, the biochemical progression-free survival was 93% (95% CI = 84.7% to 100%. Acute side effects resolved within 1-3 months of treatment completion. There were no grade 4 toxicities. No late grade 3 rectal toxicity occurred, and only one late grade 3 genitourinary toxicity occurred following repeated urologic instrumentation. Conclusion Five-year results of SBRT for localized prostate cancer demonstrate the efficacy and safety of shorter courses of high dose per fraction radiation delivered with SBRT technique. Ongoing clinical trials are underway to further explore this treatment approach.

  1. Fractionated stereotactic radiotherapy in brain tumors and cervical region. Experience of the Dean Funes Medical Center, first experience in stereotactic radiotherapy and radiosurgery inside the country

    International Nuclear Information System (INIS)

    Castro Vita, H.; Brunetto, M.; Derechinsky, V; Derechinsky, G.; Derechinsky, M.; Gonzalez, S.; Marinello, A.

    2004-01-01

    Purpose: A retrospective study to analyze the results of 53 patients treated with stereotactic radiotherapy in 'Centro Medico Dean Funes' was performed. The patients had brain and head and neck tumors. Patients and methods: From November 1997 to March 2003, 53 patients were treated with stereotactic radiotherapy in 'Centro Medico Dean Funes'. The daily dose administered varied from 1.8 to 2 Gy and the total dose from 30 to 70 Gy. The minimal follow up was 2 months, and the medium follow up 32 months. Local control and survival were analyzed in all patients, as well as tolerance and the complications of the treatment. Results: Since these series represented a very heterogeneous group of patients, the final results were very difficult to compare with other alternative treatments. However, an excellent tolerance to therapy was observed. Some subsets of patients had good results to treatment: patients with metastasis to the orbit, patients with lesions to the sellar and parasellar regions and some who relapsed following conventional radiotherapy, mainly lymphomas. Conclusions: Stereotactic radiotherapy is a valid therapeutic method to treat tumors of the brain and head and neck, as long as the tumor has a moderate size (6 cm. or less) and the shape is cylindrical or ellipsoid. Stereotactic radiation improves the therapeutic ratio as compared with the conventional radiotherapy. It has advantages over the 3D technique, and could compete with IMRT (Intensity modulated radiation therapy). (author) [es

  2. Stereotactic radiotherapy for non-small cell lung cancer: From concept to clinical reality. 2011 update

    International Nuclear Information System (INIS)

    Girard, N.; Mornex, F.

    2011-01-01

    Only 60% of patients with early-stage non-small cell lung cancer (NSCLC), a priori bearing a favorable prognosis, undergo radical resection because of the very frequent co-morbidities occurring in smokers, precluding surgery to be safely performed. Stereotactic radiotherapy consists of the use of multiple radiation micro-beams, allowing high doses of radiation to be delivered to the tumour (ranging from 7.5 to 20 Gy per fraction) in a small number of fractions (one to eight on average). Several studies with long-term follow-up are now available, showing the effectiveness of stereotactic radiotherapy to control stage I/II non-small cell lung cancer in medically inoperable patients. Local control rates are consistently reported to be above 95% with a median survival of 34 to 45 months. Because of these excellent results, stereotactic radiation therapy is now being evaluated in operable patients in several randomized trials with a surgical arm. Ultimately, the efficacy of stereotactic radiotherapy in early-stage tumours leads to hypothesize that it may represent an opportunity for locally-advanced tumors. The specific toxicities of stereotactic radiotherapy mostly correspond to radiation-induced chest wall side effects, especially for peripheral tumours. The use of adapted fractionation schemes has made feasible the use of stereotactic radiotherapy to treat proximal tumours. Overall, from a technical concept to the availability of specific treatment devices and the publication of clinical results, stereotactic radiotherapy represents a model of implementation in thoracic oncology. (authors)

  3. Fractionated brain stereotactic radiotherapy: assessment of repositioning precision using a thermoforming mask

    International Nuclear Information System (INIS)

    Barret, A.; Champeaux-Orange, E.; Bouscayrol, H.; Wachter, T.

    2011-01-01

    The authors report a study which aimed at assessing the patient repositioning precision obtained with a support system used during a brain fractionated stereotactic radiotherapy and comprising a thermoforming mask (Elektra head mask). The repositioning is assessed by means of scano-graphies and superimposition with the stereotactic frame. A three-dimensional vector has been computed for each patient. The average displacement corresponds to that published in literature. The high quality of the support system allows a non invasive brain stereotactic radiotherapy to be performed which is also comfortable for the patient. Short communication

  4. A neurosurgery/stereotactic radiotherapy dedicated PACS for conformal radiotherapy

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Bocquiault, P.; Levrier, M.; Merienne, L.; Schlienger, M.

    1995-01-01

    To realise conformal cerebral stereotactic irradiations we use a Neurosurgery/stereotactic dedicated PACS between two distant hospitals. It connects the stereotactic neurosurgery planification imaging system NEUROAXIS (Sopelem-Sofretec/Ste Anne Hospital) with the dosimetric TPS ARTEMIS-3D/Dosigray (Tenon Hospital). NEUROAXIS is a computer aided stereotactic biopsies and stereo-electroencephalographies, used by surgeons in operating room. The system determines the precise location data for Talairach radiological equipment (X ray source at 5 meters from film) and the geometry of scanner and MRI stereotactical referentials. It provides a full set of features for lesion localization, geometrical computations, surgical planifications, picture archiving, stereotactic angiography, CT and MRI image processing and networking. It sends images through the French public digital network ISDN (NUMERIS/France Telecom : 2x64 Kbits/s) from Ste Anne to Tenon Hospital. Stereotactic angiographic and CT images are reformatted into the DOSIGRAY image processing environment where 3-D dose distributions, displays and DVHs are computed to determine the optimal treatment. ARTEMIS-3D/Dosigray is a TPS for stereotactic radiotherapy devised by the Tenon Hospital for clinical methodology and 3D dose calculations, optimization software development and the Dosigray company for multimodality imaging, (2D(3D)) computer graphics for dose and anatomical representation and data networking. Communication within the radiation oncology department is provided by local area ETHERNET network, linking heterogeneous systems (Vaxstations-3200; Decstation (5000(240))) by means of different protocols. The works in progress are to send back via the same network the 3-D dose matrix to Neurosurgery department NEUROAXIS system. Our PACS is used since six months to treat patients. It has permitted to improve the treatment quality in comparison with our first version TPS ARTEMIS-3D

  5. Sexual Function After Stereotactic Body Radiotherapy for Prostate Cancer: Results of a Prospective Clinical Trial

    International Nuclear Information System (INIS)

    Wiegner, Ellen A.; King, Christopher R.

    2010-01-01

    Purpose: To study the sexual quality of life for prostate cancer patients after stereotactic body radiotherapy (SBRT). Methods and Materials: Using the Expanded Prostate Cancer Index Composite (EPIC)-validated quality-of-life questionnaire, the sexual function of 32 consecutive patients who received prostate SBRT in a prospective Phase II clinical trial were analyzed at baseline, and at median times of 4, 12, 20, and 50 months after treatment. SBRT consisted of 36.25 Gy in five fractions of 7.25 Gy using the Cyberknife. No androgen deprivation therapy was given. The use of erectile dysfunction (ED) medications was monitored. A comprehensive literature review for radiotherapy-alone modalities based on patient self-reported questionnaires served as historical comparison. Results: Median age at treatment was 67.5 years, and median follow-up was 35.5 months (minimum 12 months). The mean EPIC sexual domain summary score, sexual function score, and sexual bother score decreased by 45%, 49%, and 25% respectively at 50 months follow-up. These differences reached clinical relevance by 20 months after treatment. Baseline ED rate was 38% and increased to 71% after treatment (p = 0.024). Use of ED medications was 3% at baseline and progressed to 25%. For patients aged <70 years at follow-up, 60% maintained satisfactory erectile function after treatment compared with only 12% aged ≥70 years (p = 0.008). Penile bulb dose was not associated with ED. Conclusions: The rates of ED after treatment appear comparable to those reported for other modalities of radiotherapy. Given the modest size of this study and the uncertainties in the physiology of radiotherapy-related ED, these results merit further investigations.

  6. Establishing a process of irradiating small animal brain using a CyberKnife and a microCT scanner

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Haksoo; Welford, Scott [Department of Radiation Oncology, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 (United States); Fabien, Jeffrey; Zheng, Yiran; Yuan, Jake; Brindle, James; Yao, Min; Lo, Simon; Wessels, Barry; Machtay, Mitchell; Sohn, Jason W., E-mail: jason.sohn@case.edu [Department of Radiation Oncology, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 and University Hospitals of Cleveland, 11100 Euclid Avenue, Cleveland, Ohio 44106 (United States); Sloan, Andrew [Department of Neurosurgery, School of Medicine, Case Western Reserve University, 10900 Euclid Avenue, Cleveland, Ohio 44106 (United States)

    2014-02-15

    Purpose: Establish and validate a process of accurately irradiating small animals using the CyberKnife G4 System (version 8.5) with treatment plans designed to irradiate a hemisphere of a mouse brain based on microCT scanner images. Methods: These experiments consisted of four parts: (1) building a mouse phantom for intensity modulated radiotherapy (IMRT) quality assurance (QA), (2) proving usability of a microCT for treatment planning, (3) fabricating a small animal positioning system for use with the CyberKnife's image guided radiotherapy (IGRT) system, and (4)in vivo verification of targeting accuracy. A set of solid water mouse phantoms was designed and fabricated, with radiochromic films (RCF) positioned in selected planes to measure delivered doses. After down-sampling for treatment planning compatibility, a CT image set of a phantom was imported into the CyberKnife treatment planning system—MultiPlan (ver. 3.5.2). A 0.5 cm diameter sphere was contoured within the phantom to represent a hemispherical section of a mouse brain. A nude mouse was scanned in an alpha cradle using a microCT scanner (cone-beam, 157 × 149 pixels slices, 0.2 mm longitudinal slice thickness). Based on the results of our positional accuracy study, a planning treatment volume (PTV) was created. A stereotactic body mold of the mouse was “printed” using a 3D printer laying UV curable acrylic plastic. Printer instructions were based on exported contours of the mouse's skin. Positional reproducibility in the mold was checked by measuring ten CT scans. To verify accurate dose delivery in vivo, six mice were irradiated in the mold with a 4 mm target contour and a 2 mm PTV margin to 3 Gy and sacrificed within 20 min to avoid DNA repair. The brain was sliced and stained for analysis. Results: For the IMRT QA using a set of phantoms, the planned dose (6 Gy to the calculation point) was compared to the delivered dose measured via film and analyzed using Gamma analysis (3% and 3 mm

  7. Phantom-to-clinic development of hypofractionated stereotactic body radiotherapy for early-stage glottic laryngeal cancer

    Energy Technology Data Exchange (ETDEWEB)

    Ding, Chuxiong [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Chun, Stephen G. [Department of Radiation Oncology, University of Texas M.D. Anderson Cancer Center, Houston, TX (United States); Sumer, Baran D. [Department of Otolaryngology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Nedzi, Lucien A.; Abdulrahman, Ramzi E. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Yordy, John S. [Valley Radiation Therapy Center, Anchorage, AK (United States); Lee, Pam; Hrycushko, Brian [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Solberg, Timothy D. [Department of Radiation Oncology, Abramson Comprehensive Cancer Center, Perelman School of Medicine, University of Pennsylvania, Philadelphia, PA (United States); Ahn, Chul [Department of Clinical Sciences, University of Texas Southwestern Medical Center, Dallas, TX (United States); Timmerman, Robert D. [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States); Schwartz, David L., E-mail: david.schwartz214@gmail.com [Department of Radiation Oncology, Simmons Cancer Center, University of Texas Southwestern Medical Center, Dallas, TX (United States)

    2017-07-01

    The purpose of this study was to commission and clinically test a robotic stereotactic delivery system (CyberKnife, Sunnyvale, CA) to treat early-stage glottic laryngeal cancer. We enrolled 15 patients with cTis-T2N0M0 carcinoma of the glottic larynx onto an institutional review board (IRB)-approved clinical trial. Stereotactic body radiotherapy (SBRT) plans prescribed 45 Gy/10 fractions to the involved hemilarynx. SBRT dosimetry was compared with (1) standard carotid-sparing laryngeal intensity-modulated radiation therapy (IMRT) and (2) selective hemilaryngeal IMRT. Our results demonstrate that SBRT plans improved sparing of the contralateral arytenoid (mean 20.0 Gy reduction, p <0.001), ipsilateral carotid D{sub max} (mean 20.6 Gy reduction, p <0.001), contralateral carotid D{sub max} (mean 28.1 Gy reduction, p <0.001), and thyroid D{sub mean} (mean 15.0 Gy reduction, p <0.001) relative to carotid-sparing IMRT. SBRT also modestly improved dose sparing to the contralateral arytenoid (mean 4.8 Gy reduction, p = 0.13) and spinal cord D{sub max} (mean 4.9 Gy reduction, p = 0.015) relative to selective hemilaryngeal IMRT plans. This “phantom-to-clinic” feasibility study confirmed that hypofractionated SBRT treatment for early-stage laryngeal cancer can potentially spare dose to adjacent normal tissues relative to current IMRT standards. Clinical efficacy and toxicity correlates continue to be collected through an ongoing prospective trial.

  8. Dosimetric verification of stereotactic radiosurgery/stereotactic radiotherapy dose distributions using Gafchromic EBT3

    Energy Technology Data Exchange (ETDEWEB)

    Cusumano, Davide, E-mail: davide.cusumano@unimi.it [School of Medical Physics, University of Milan, Milan (Italy); Fumagalli, Maria L. [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); Marchetti, Marcello; Fariselli, Laura [Department of Neurosurgery, Radiotherapy Unit, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy); De Martin, Elena [Health Department, Fondazione IRCCS Istituto Neurologico Carlo Besta, Milan (Italy)

    2015-10-01

    Aim of this study is to examine the feasibility of using the new Gafchromic EBT3 film in a high-dose stereotactic radiosurgery and radiotherapy quality assurance procedure. Owing to the reduced dimensions of the involved lesions, the feasibility of scanning plan verification films on the scanner plate area with the best uniformity rather than using a correction mask was evaluated. For this purpose, signal values dispersion and reproducibility of film scans were investigated. Uniformity was then quantified in the selected area and was found to be within 1.5% for doses up to 8 Gy. A high-dose threshold level for analyses using this procedure was established evaluating the sensitivity of the irradiated films. Sensitivity was found to be of the order of centiGray for doses up to 6.2 Gy and decreasing for higher doses. The obtained results were used to implement a procedure comparing dose distributions delivered with a CyberKnife system to planned ones. The procedure was validated through single beam irradiation on a Gafchromic film. The agreement between dose distributions was then evaluated for 13 patients (brain lesions, 5 Gy/die prescription isodose ~80%) using gamma analysis. Results obtained using Gamma test criteria of 5%/1 mm show a pass rate of 94.3%. Gamma frequency parameters calculation for EBT3 films showed to strongly depend on subtraction of unexposed film pixel values from irradiated ones. In the framework of the described dosimetric procedure, EBT3 films proved to be effective in the verification of high doses delivered to lesions with complex shapes and adjacent to organs at risk.

  9. CyberKnife radiosurgery: Precision without incision

    Directory of Open Access Journals (Sweden)

    Enja Siva Prasad Reddy

    2015-01-01

    Full Text Available CyberKnife stereotactic radiosurgery system is an innovative, effective, frameless, non-invasive substitute for conventional surgical treatment of cancer. It works on the principle of stereotaxy. It is used for the treatment of both cancerous and non-cancerous tumors, intracranial lesions, tumors of lung, spine, prostate, and kidney, recurrent cases of oral squamous cell carcinoma, arteriovenous malformation, and trigeminal neuralgia. It has an advantage over other systems like Gamma knife radiosurgery and linear accelerator (LINAC-based systems, as it is frameless, has submillimeter accuracy, does not affect the normal cells adjacent to the lesion, and tracks the lesion in synchronization with the patient′s respiratory rate. The future of CyberKnife encompasses possibilities such as incremental improvements in accuracy and better shaping of the field of radiation and would certainly allow extension of radiosurgery as an effective substitute for chemotherapy. This paper aims to review and highlight the immense potential that CyberKnife holds in the field of dentistry in treating disorders of the head and neck region, thereby ensuring enhanced longevity for the patients.

  10. Treatment by stereotactic radiotherapy of tumoral injuries after implant placement: preliminary study

    International Nuclear Information System (INIS)

    Meingan, P.; Rio, E.; Labbe-Devilliers, C.; Geffroy, D.; Ricaud-Couprie, M.; Doutriaux-Dumoulin, I.

    2009-01-01

    Objective: to evaluate the interest and the place of stereotactic radiotherapy in the treatment of primitive or secondary tumoral injuries of the liver. To describe the technique of implants placement. Conclusion: the liver stereotactic radiotherapy, after implant placement, seems to be an alternative or complementary therapy to the radiofrequency for patients refused for surgery, with moderated side effects and a noticeable survival. Complementary studies, especially associated to radiofrequency must be considered. (N.C.)

  11. Noninvasive patient fixation for extracranial stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Lohr, Frank; Debus, Juergen; Frank, Claudia; Herfarth, Klaus; Pastyr, Otto; Rhein, Bernhard; Bahner, Malte L.; Schlegel, Wolfgang; Wannenmacher, Michael

    1999-01-01

    Purpose: To evaluate the setup accuracy that can be achieved with a novel noninvasive patient fixation technique based on a body cast attached to a recently developed stereotactic body frame during fractionated extracranial stereotactic radiotherapy. Methods and Materials: Thirty-one CT studies (≥ 20 slices, thickness: 3 mm) from 5 patients who were immobilized in a body cast attached to a stereotactic body frame for treatment of para medullary tumors in the thoracic or lumbar spine were evaluated with respect to setup accuracy. The immobilization device consisted of a custom-made wrap-around body cast that extended from the neck to the thighs and a separate head mask, both made from Scotchcast. Each CT study was performed immediately before or after every second or third actual treatment fraction without repositioning the patient between CT and treatment. The stereotactic localization system was mounted and the isocenter as initially located stereo tactically was marked with fiducials for each CT study. Deviation of the treated isocenter as compared to the planned position was measured in all three dimensions. Results: The immobilization device can be easily handled, attached to and removed from the stereotactic frame and thus enables treatment of multiple patients with the same stereotactic frame each day. Mean patient movements of 1.6 mm ± 1.2 mm (laterolateral [LL]), 1.4 mm ± 1.0 mm (anterior-posterior [AP]), 2.3 mm ± 1.3 mm (transversal vectorial error [VE]) and < slice thickness = 3 mm (cranio caudal [CC]) were recorded for the targets in the thoracic spine and 1.4 mm ± 1.0 mm (LL), 1.2 mm ± 0.7 mm (AP), 1.8 mm ± 1.2 mm (VE), and < 3 mm (CC) for the lumbar spine. The worst case deviation was 3.9 mm for the first patient with the target in the thoracic spine (in the LL direction). Combining those numbers (mean transversal VE for both locations and maximum CC error of 3 mm), the mean three-dimensional vectorial patient movement and thus the mean overall

  12. Percutaneous fiducial marker placement prior to stereotactic body radiotherapy for malignant liver tumors: an initial experience

    International Nuclear Information System (INIS)

    Ohta, Kengo; Shimohira, Masashi; Murai, Taro; Nishimura, Junichi; Iwata, Hiromitsu; Ogino, Hiroyuki; Hashizume, Takuya; Shibamoto, Yuta

    2016-01-01

    The aim of this study was to describe our initial experience with a gold flexible linear fiducial marker and to evaluate the safety and technical and clinical efficacy of stereotactic body radiotherapy using this marker for malignant liver tumors. Between July 2012 and February 2015, 18 patients underwent percutaneous fiducial marker placement before stereotactic body radiotherapy for malignant liver tumors. We evaluated the technical and clinical success rates of the procedure and the associated complications. Technical success was defined as successful placement of the fiducial marker at the target site, and clinical success was defined as the completion of stereotactic body radiotherapy without the marker dropping out of position. All 18 fiducial markers were placed successfully, so the technical success rate was 100% (18/18). All 18 patients were able to undergo stereotactic body radiotherapy without marker migration. Thus, the clinical success rate was 100% (18/18). Slight pneumothorax occurred as a minor complication in one case. No major complications such as coil migration or bleeding were observed. The examined percutaneous fiducial marker was safely placed in the liver and appeared to be useful for stereotactic body radiotherapy for malignant liver tumors

  13. Primary lung sarcoma treated with stereotactic ablative radiotherapy: a case report

    Directory of Open Access Journals (Sweden)

    Yeo SG

    2017-07-01

    Full Text Available Seung-Gu Yeo Department of Radiation Oncology, Soonchunhyang University College of Medicine, Soonchunhyang University Hospital, Cheonan, Republic of Korea Abstract: Primary lung sarcoma (PLS is an extremely rare, very aggressive malignancy. Surgical removal is considered the treatment of choice, and patients who have been given conventional radiotherapy have had inferior outcomes. This study is the first describing a case of PLS treated with stereotactic ablative radiotherapy (SABR, which precisely targets a small tumor with a markedly higher biologically effective dose than conventional radiotherapy. The patient was an 82-year-old man who was diagnosed with primary lung leiomyosarcoma based on radiology, pathology, and immunohistochemical examinations. The PLS was located in the right lower lobe and measured 2.5 cm. No regional nodal or distant organ metastasis was observed. He was inoperable medically. The SABR was performed using volumetric modulated arc therapy and a dose of 56 Gy in four fractions. Follow-up computed tomography 2 months after SABR revealed a complete tumor response. The toxicity was limited to mild respiratory symptoms. The patient is alive and has had no evidence of disease for 2 years. This study suggests that SABR can be a safe and effective treatment option for PLS. Keywords: primary lung sarcoma, leiomyosarcoma, stereotactic ablative radiotherapy, stereotactic body radiotherapy, radiation therapy, sarcoma 

  14. Stereotactic body radiotherapy in lung cancer: an update

    Energy Technology Data Exchange (ETDEWEB)

    Abreu, Carlos Eduardo Cintra Vita; Ferreira, Paula Pratti Rodrigues; Moraes, Fabio Ynoe de; Neves Junior, Wellington Furtado Pimenta; Carvalho, Heloisa de Andrade, E-mail: heloisa.carvalho@hc.fm.usp.br [Hospital Sirio-Libanes, Sao Paulo, SP (Brazil). Departamento de Radioterapia; Gadia, Rafael [Hospital Sirio-Libanes, Brasilia, DF (Brazil). Departamento de Radioterapia; Universidade de Sao Paulo (USP), Sao Paulo, SP (Brazil). Departamento de Radiologia e Oncologia. Servico de Radioterapia

    2015-07-15

    For early-stage lung cancer, the treatment of choice is surgery. In patients who are not surgical candidates or are unwilling to undergo surgery, radiotherapy is the principal treatment option. Here, we review stereotactic body radiotherapy, a technique that has produced quite promising results in such patients and should be the treatment of choice, if available. We also present the major indications, technical aspects, results, and special situations related to the technique. (author)

  15. Reproducibility and geometric accuracy of the fixster system during hypofractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Lindvall, Peter; Bergström, Per; Löfroth, Per-Olov; Henriksson, Roger; Bergenheim, A Tommy

    2008-01-01

    Hypofractionated radiotherapy has been used for the treatment of AVMs and brain metastases. Hypofractionation necessitates the use of a relocatable stereotactic frame that has to be applied on several occasions. The stereotactic frame needs to have a high degree of reproducibility, and patient positioning is crucial to achieve a high accuracy of the treatment. In this study we have, by radiological means, evaluated the reproducibility of the isocenter in consecutive treatment sessions using the Fixster frame. Deviations in the X, Y and Z-axis were measured in 10 patients treated with hypofractionated radiotherapy. The mean deviation in the X-axis was 0.4 mm (range -2.1 – 2.1, median 0.7 mm) and in the Y-axis -0.3 mm (range -1.4 – 0.7, median -0.2 mm). The mean deviation in the Z-axis was -0.6 (range -1.4 – 1.4, median 0.0 mm). There is a high degree of reproducibility of the isocenter during successive treatment sessions with HCSRT using the Fixster frame for stereotactic targeting. The high reducibility enables a safe treatment using hypofractionated stereotactic radiotherapy

  16. Robotic Image-Guided Stereotactic Radiotherapy, for Isolated Recurrent Primary, Lymph Node or Metastatic Prostate Cancer

    International Nuclear Information System (INIS)

    Jereczek-Fossa, Barbara Alicja; Beltramo, Giancarlo; Fariselli, Laura; Fodor, Cristiana; Santoro, Luigi; Vavassori, Andrea; Zerini, Dario; Gherardi, Federica; Ascione, Carmen; Bossi-Zanetti, Isa; Mauro, Roberta; Bregantin, Achille; Bianchi, Livia Corinna; De Cobelli, Ottavio; Orecchia, Roberto

    2012-01-01

    Purpose: To evaluate the outcome of robotic CyberKnife (Accuray, Sunnyvale, CA)–based stereotactic radiotherapy (CBK-SRT) for isolated recurrent primary, lymph node, or metastatic prostate cancer. Methods and Materials: Between May 2007 and December 2009, 34 consecutive patients/38 lesions were treated (15 patients reirradiated for local recurrence [P], 4 patients reirradiated for anastomosis recurrence [A], 16 patients treated for single lymph node recurrence [LN], and 3 patients treated for single metastasis [M]). In all but 4 patients, [ 11 C]choline positron emission tomography/computed tomography was performed. CBK-SRT consisted of reirradiation and first radiotherapy in 27 and 11 lesions, respectively. The median CBK-SRT dose was 30 Gy in 4.5 fractions (P, 30 Gy in 5 fractions; A, 30 Gy in 5 fractions; LN, 33 Gy in 3 fractions; and M, 36 Gy in 3 fractions). In 18 patients (21 lesions) androgen deprivation was added to CBK-SRT (median duration, 16.6 months). Results: The median follow-up was 16.9 months. Acute toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event). Late toxicity included urinary events (3 Grade 1, 2 Grade 2, and 2 Grade 3 events) and rectal events (1 Grade 1 event and 1 Grade 2 event). Biochemical response was observed in 32 of 38 evaluable lesions. Prostate-specific antigen stabilization was seen for 4 lesions, and in 2 cases prostate-specific antigen progression was reported. The 30-month progression-free survival rate was 42.6%. Disease progression was observed for 14 lesions (5, 2, 5, and 2 in Groups P, A, LN, and M respectively). In only 3 cases, in-field progression was seen. At the time of analysis (May 2010), 19 patients are alive with no evidence of disease and 15 are alive with disease. Conclusions: CyberKnife-based stereotactic radiotherapy is a feasible approach for isolated recurrent primary, lymph node, or metastatic prostate cancer, offering excellent in-field tumor

  17. Initial treatment results using cyberknife for head and neck tumor

    International Nuclear Information System (INIS)

    Himei, Kengo; Katsui, Kuniaki; Yoshida, Atsushi; Takemoto, Mitsuhiro; Kobayashi, Mitsuru; Kuroda, Masahiro; Hiraki, Yoshio

    2002-01-01

    The CyberKnife, a medical device for stereotactic radiotherapy, is composed of a combination of a robot manipulator and LINAC. For the treatment of head and neck tumors, this system has been applied. Between June 2000 and January 2001, 18 patients with head and neck tumor were treated with this system because of tumor recurrence, difficulty in surgery or additional increase after external radiotherapy. The median age was 64 years. Primary lesions were skull base (4), nasopharynx (3), paranasal sinus (3), nasal cavity (2), lacrimal gland (1), oropharynx (1), oral floor (1), and buccul mucosa (1), metastatic lymph nodes were found in three. The prescribed dose was 12-38 Gy as for marginal dose. The response rate (CR+PR) was 44.4% and local control rate (CR+PR+NC) was 77.8%. The adverse effects were assessed by the NCI-CTC Version 2.0 and observed grade 3 in two cases. Our early experience indicates that this system could to be feasible for the treatment of locally advanced or recurrent head and neck tumor, and for the reduction of adverse effect and maintenance of useful QOL of patients. (author)

  18. Determination of acquisition frequency for intrafractional motion of pancreas in CyberKnife radiotherapy.

    Science.gov (United States)

    Zhang, Huailing; Zhao, Guoru; Djajaputra, David; Xie, Yaoqin

    2014-01-01

    To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval) and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

  19. Setup verification in stereotactic radiotherapy using digitally reconstructed radiograph (DRR)

    International Nuclear Information System (INIS)

    Cho, Byung Chul; Oh, Do Hoon; Bae, Hoon Sik

    1999-01-01

    To develop a method for verifying a treatment setup in stereotactic radiotherapy by matching portal images to DRRs. Four pairs of orthogonal portal images of one patient immobilized by a thermoplastic mast frame for fractionated stereotactic radiotherapy were compared with DRRs. Portal images are obtained in AP (anterior/posterior) and lateral directions with a target localizer box containing fiducial markers attached to a stereotactic frame. DRRs superimposed over a planned isocenter and fiducial markers are printed out on transparent films. And then, they were overlaid over orthogonal portal images by matching anatomical structures. From three different kind of objects (isocenter, fiducial markers, anatomical structure) on DRRs and portal images, the displacement error between anatomical structure and isocenters (overall setup error), and the displacement error between fiducial markers and isocenters (localization error)were measured. Localization errors were 1.5±0.3 mm (lateral), and immobilization errors were 1.9±0.5 mm (AP), 1.9±0.4 mm (lateral). In addition, overall setup errors were 1.6±0.9 mm (AP), 1.3±0.4 mm(lateral). From these orthogonal displacement errors, maximum 3D displacement errors(√(ΔAP) 2 +(ΔLat) 2 ) were found to be 1.7±0.4 mm for localization, 2.6±0.6 mm for immobilization, and 2.3±0.7 mm for overall treatment setup. By comparing orthogonal portal images with DRRs, we find out that it is possible to verify treatment setup directly in stereotactic radiotherapy

  20. Stereotactic Image-Guided Intensity Modulated Radiotherapy Using the HI-ART II Helical Tomotherapy System

    International Nuclear Information System (INIS)

    Holmes, Timothy W.; Hudes, Richard; Dziuba, Sylwester; Kazi, Abdul; Hall, Mark; Dawson, Dana

    2008-01-01

    The highly integrated adaptive radiation therapy (HI-ART II) helical tomotherapy unit is a new radiotherapy machine designed to achieve highly precise and accurate treatments at all body sites. The precision and accuracy of the HI-ART II is similar to that provided by stereotactic radiosurgery systems, hence the historical distinction between external beam radiotherapy and stereotactic procedures based on differing precision requirements is removed for this device. The objectives of this work are: (1) to describe stereotactic helical tomotherapy processes (SRS, SBRT); (2) to show that the precision and accuracy of the HI-ART meet the requirements defined for SRS and SBRT; and (3) to describe the clinical implementation of a stereotactic image-guided intensity modulated radiation therapy (IG-IMRT) system that incorporates optical motion management

  1. Clinical experience with a new stereotactic localisation method for fractionated radiotherapy of extracranial lesions

    International Nuclear Information System (INIS)

    Engenhart-Cabillic, R.; Pastyr, O.; Wenz, F.; Debus, J.; Schlegel, W.; Bahner, M.L.; Wannenmacher, M.

    1996-01-01

    Purpose/Objective: Effectiveness of radiotherapy in terms of local control has been shown to be linked with treatment accuracy. Conformal radiation therapy outside the brain maybe limited by relative inaccuracy of positioning and repositioning uncertainty during treatment planning, simulation and radiotherapy. It has been shown that stereotactic localisation methods provide an excellent localisation accuracy for intracranial lesions. The aim of this study was to develop a stereotactic system for the whole body and to test the feasibility in a clinical study. Materials and Method: The system includes a reversible stereotactic patient fixation, localization and positioning system which can be used during CT-imaging for simulation and for treatment. The target volume and adjacent critical structures were outlined for treatment three dimensional planning and the coordinates of the target point were calculated. The overall accuracy of target localization including soft and hardware inaccuracy was measured by a phantom. Three patients with spinal and paraspinal tumors were treated by conventionally fractionated high precision megavoltage radiotherapy with this system. The treatment time was 6 weeks in each patients. The stereotactic coordinates of anatomical landmarks as well as implanted fiducals were measured by CT-imaging, X-ray localization and electronic portal imaging at 20 different paraspinal localisations. Stereotactic CT-imaging was performed for treatment planning and once a week during treatment. Results: Standard deviation of stereotactic coordinats in the phantom was 0.5 mm in the lateral direction (x), 1.0 mm in the cranio-caudal orientation (z) and 1.2 mm in the dorso-ventral orientation. About 60 minutes are required to immobilise the patient properly for the first set-up and the subsequent daily set-up time during therapy was 10 min. In patients a total of 18 CT examination and 56 portal images have been analysed. The mean variation of the stereotactic

  2. Utility Estimation of the Manufactured Stereotactic Body Radiotherapy Immobilization

    International Nuclear Information System (INIS)

    Lee, Dong Hoon; Ahn, Jong Ho; Seo, Jeong Min; Shin, Eun Hyeak; Choi, Byeong Gi; Song, Gi Won

    2011-01-01

    Immobilizations used in order to maintain the reproducibility of a patient set-up and the stable posture for a long period are important more than anything else for the accurate treatment when the stereotactic body radiotherapy is underway. So the purpose of this study is to adapt the optimum immobilizations for the stereotactic body radiotherapy by comparing two commercial immobilizations with the self-manufactured immobilizations. Five people were selected for the experiment and three different immobilizations (A: Wing-board, B: BodyFix system, C: Arm up holder with vac-lock) were used to each target. After deciding on the target's most stable respiratory cycles, the targets were asked to wear a goggle monitor and maintain their respiration regularly for thirty minutes to obtain the respiratory signals. To analyze the respiratory signal, the standard deviation and the variation value of the peak value and the valley value of the respiratory signal were separated by time zone with the self-developed program at the hospital and each tie-downs were compared for the estimation by calculating a comparative index using the above. The stability of each immobilizations were measured in consideration of deviation changes studied in each respiratory time lapse. Comparative indexes of each immobilizations of each experimenter are shown to be A: 11.20, B: 4.87, C: 1.63 / A: 3.94, B: 0.67, C: 0.13 / A: 2.41, B: 0.29, C: 0.04 / A: 0.16, B: 0.19, C: 0.007 / A: 35.70, B: 2.37, C: 1.86. And when all five experimenters wore the immobilizations C, the test proved the most stable value while four people wearing A and one man wearing D expressed relatively the most unstable respiratory outcomes. The self-developed immobilizations, so called the arm up holder vac-lock for the stereotactic body radiotherapy is expected to improve the effect of the treatment by decreasing the intra-fraction organ motions because it keeps the respiration more stable than other two immobilizations

  3. The Confluence of Stereotactic Ablative Radiotherapy and Tumor Immunology

    Directory of Open Access Journals (Sweden)

    Steven Eric Finkelstein

    2011-01-01

    Full Text Available Stereotactic radiation approaches are gaining more popularity for the treatment of intracranial as well as extracranial tumors in organs such as the liver and lung. Technology, rather than biology, is driving the rapid adoption of stereotactic body radiation therapy (SBRT, also known as stereotactic ablative radiotherapy (SABR, in the clinic due to advances in precise positioning and targeting. Dramatic improvements in tumor control have been demonstrated; however, our knowledge of normal tissue biology response mechanisms to large fraction sizes is lacking. Herein, we will discuss how SABR can induce cellular expression of MHC I, adhesion molecules, costimulatory molecules, heat shock proteins, inflammatory mediators, immunomodulatory cytokines, and death receptors to enhance antitumor immune responses.

  4. Clinical treatment planning for stereotactic radiotherapy, evaluation by Monte Carlo simulation

    International Nuclear Information System (INIS)

    Kairn, T.; Aland, T.; Kenny, J.; Knight, R.T.; Crowe, S.B.; Langton, C.M.; Franich, R.D.; Johnston, P.N.

    2010-01-01

    Full text: This study uses re-evaluates the doses delivered by a series of clinical stereotactic radiotherapy treatments, to test the accuracy of treatment planning predictions for very small radiation fields. Stereotactic radiotherapy treatment plans for meningiomas near the petrous temporal bone and the foramen magnum (incorp rating fields smaller than I c m2) were examined using Monte Carlo simulations. Important differences between treatment planning predictions and Monte Carlo calculations of doses delivered to stereotactic radiotherapy patients are apparent. For example, in one case the Monte Carlo calculation shows that the delivery a planned meningioma treatment would spare the patient's critical structures (eyes, brainstem) more effectively than the treatment plan predicted, and therefore suggests that this patient could safely receive an increased dose to their tumour. Monte Carlo simulations can be used to test the dose predictions made by a conventional treatment planning system, for dosimetrically challenging small fields, and can thereby suggest valuable modifications to clinical treatment plans. This research was funded by the Wesley Research Institute, Australia. The authors wish to thank Andrew Fielding and David Schlect for valuable discussions of aspects of this work. The authors are also grateful to Muhammad Kakakhel, for assisting with the design and calibration of our linear accelerator model, and to the stereotactic radiation therapy team at Premion, who designed the treatment plans. Computational resources and services used in this work were provided by the HPC and Research Support Unit, QUT, Brisbane, Australia. (author)

  5. Cerebral control and survival after stereotactic radiotherapy of brain metastases

    International Nuclear Information System (INIS)

    Arnold, Elmar Till

    2014-01-01

    This retrospective study, including 275 patients who underwent stereotactic radiotherapy due to brain metastases between 2003 and 2008, investigates influencing factors regarding cerebral control and survival, symptomatic effects and a potential benefit for patients older than 70 years. We were able to identify risk factors for remote brain failure which leads to a therapeutic recommendation. Furthermore we confirm a positive symptomatic effect and a benefit of stereotactic readiotherapy for patients over 70 years.

  6. Determination of Acquisition Frequency for Intrafractional Motion of Pancreas in CyberKnife Radiotherapy

    Directory of Open Access Journals (Sweden)

    Huailing Zhang

    2014-01-01

    Full Text Available Purpose. To report the characteristics of pancreas motion as tracked using implanted fiducials during radiotherapy treatments with CyberKnife. Methods and Materials. Twenty-nine patients with pancreas cancer treated using CyberKnife system were retrospectively selected for this study. During the treatment, the deviation is examined every 3-4 nodes (~45 s interval and compensated by the robot. The pancreas displacement calculated from X-ray images acquired within the time interval between two consecutive couch motions constitute a data set. Results. A total of 498 data sets and 4302 time stamps of X-ray images were analyzed in this study. The average duration for each data set is 634 s. The location of the pancreas becomes more dispersed as the time elapses. The acquisition frequency depends on the prespecified movement distance threshold of pancreas. If the threshold between two consecutive images is 1 mm, the acquisition frequency should be less than 30 s, while if the threshold is 2 mm, the acquisition frequency can be around 1 min. Conclusions. The pancreas target moves significantly and unpredictably during treatment. Effective means of compensating the intrafractional movement is critical to ensure adequate dose coverage of the tumor target.

  7. Hypofractionated stereotactic radiotherapy for malignant tumors of the lung

    Directory of Open Access Journals (Sweden)

    О. Ю. Аникеева

    2015-10-01

    Full Text Available Hypofractionated stereotactic radiotherapy was used for 26 patients at medically inoperable stage I of non-small cell lung cancer with dose escalation of 48-54 Gy prescribed at 90 or 95% isodose level in 3-4 fractions. Nine-months local control and cancer-specific survival were 82.0 and 66.8% respectively, with minimal toxicity. For metastatic lung tumors local control was obtained in 92% cases. Hypofractionated stereotactic radiation therapy (SBRT is safe and feasible for the treatment of inoperable primary lung cancer and single lung metastasis.

  8. Frame-less image-guided intracranial and extracranial radiosurgery using the Cyberknife robotic system

    International Nuclear Information System (INIS)

    Gibbs, I.C.

    2006-01-01

    The Cyberknife TM is an image-guided robotic radiosurgery system. The image guidance system includes a kilo-voltage X-ray imaging source and amorphous silica detectors. The radiation delivery device is a mobile X-band linear accelerator mounted onto a robotic arm. Through a highly complex interplay between the image guidance system, an automated couch, and the high-speed linear accelerator, near real-time tracking of the target is achieved. The Cyberknife TM gained Federal Drug Administration clearance in the United States in 2001 for treatment of tumors 'anywhere in the body where radiation treatment is indicated'. Because the Cyberknife TM system does not rely on rigid fixation of a stereotactic frame, tumors outside of the intracranial compartment, even those tumors that move with respiration can be treated with a similar degree of ease as intracranial targets. A description of the Cyberknife TM technology and a review of some of the current intracranial and extracranial applications are detailed herein. (author)

  9. Single-centre experience of stereotactic radiosurgery and fractionated stereotactic radiotherapy for prolactinomas with the linear accelerator.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet Rosemary; Smee, Robert Ian

    2015-06-01

    Primary management of prolactinomas is usually medical, with surgery a secondary option where necessary. This study is a review of a single centre's experience with focused radiotherapy where benefit was not gained by medical or surgical approaches. Radiotherapy as an alternative and adjuvant treatment for prolactinomas has been performed at our institution with the linear accelerator since 1990. We present a retrospective review of 13 patients managed with stereotactic radiosurgery (SRS) and 5 managed with fractionated stereotactic radiotherapy (FSRT), as well as 5 managed with conventional radiotherapy, at the Prince of Wales Hospital. Patients with a histopathologically diagnosed prolactinoma were eligible. Those patients who had a confirmed pathological diagnosis of prolactinoma following surgical intervention, a prolactin level elevated above 500 μg/L, or a prolactin level persistently elevated above 200 μg/L with exclusion of other causes were represented in this review. At the end of documented follow-up (SRS median 6 years, FSRT median 2 years), no SRS patients showed an increase in tumour volume. After FSRT, 1 patient showed an increase in size, 2 showed a decrease in size and 2 patients showed no change. Prolactin levels trended towards improvement after SRS and FSRT, but no patients achieved the remission level of <20 μg/L. Seven of 13 patients in the SRS group achieved a level of <500 μg/L, whereas no patients reached this target after FSRT. A reduction in prolactin level is frequent after SRS and FSRT for prolactinomas; however, true biochemical remission is uncommon. Tumour volume control in this series was excellent, but this may be related to the natural history of the disease. Morbidity and mortality after stereotactic radiation were very low in this series. © 2014 The Royal Australian and New Zealand College of Radiologists.

  10. Stereotactic body radiotherapy for liver tumors. Principles and practical guidelines of the DEGRO Working Group on Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Sterzing, Florian [Deutsches Krebsforschungszentrum (DKFZ), Klinische Kooperationseinheit Strahlentherapie, Heidelberg (Germany); Radiologische Universitaetsklinik, Abteilung fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany); Brunner, Thomas B. [Universitaetsklinikum Freiburg, Klinik fuer Strahlenheilkunde, Radiologische Klinik, Freiburg (Germany); Ernst, Iris; Greve, Burkhard [Universitaetsklinikum Muenster, Klinik fuer Strahlentherapie - Radioonkologie, Muenster (Germany); Baus, Wolfgang W. [Universitaetsklinikum Koeln, Klinik und Poliklinik fuer Strahlentherapie, Koeln (Germany); Herfarth, Klaus [Radiologische Universitaetsklinik, Abteilung fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany); Guckenberger, Matthias [UniversitaetsSpital Zuerich, Klinik fuer Radio-Onkologie, Zuerich (Switzerland)

    2014-10-15

    This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a practical guideline for safe and effective stereotactic body radiotherapy (SBRT) of liver tumors. The literature on the clinical evidence of SBRT for both primary liver tumors and liver metastases was reviewed and analyzed focusing on both physical requirements and special biological characteristics. Recommendations were developed for patient selection, imaging, planning, treatment delivery, motion management, dose reporting, and follow-up. Radiation dose constraints to critical organs at risk are provided. SBRT is a well-established treatment option for primary and secondary liver tumors associated with low morbidity. (orig.) [German] Die Arbeitsgruppe Stereotaxie der Deutschen Gesellschaft fuer Radioonkologie (DEGRO) legt hier eine Empfehlung zur sicheren und effektiven Durchfuehrung der SBRT von Lebertumoren vor. Eine Literaturrecherche zur Untersuchung der Evidenz der SBRT sowohl fuer primaere Lebertumore als auch fuer Lebermetastasen wurde durchgefuehrt. Auf dieser Basis werden Empfehlungen fuer technisch-physikalische Voraussetzungen wie auch fuer die taegliche Praxis der Leber-SBRT gegeben. Weiterhin werden radiobiologische Besonderheiten dieses Verfahrens dargestellt. Praktische Vorgaben werden fuer Patientenselektion, Bildgebung, Planung, Applikation, Bewegungsmanagement, Dosisdokumentation und Follow-up gegeben. Dosisempfehlungen fuer die kritischen Risikoorgane werden dargestellt. Die SBRT stellt eine etablierte Behandlungsmethode fuer primaere und sekundaere Lebertumore dar und ist mit niedriger Morbiditaet assoziiert. (orig.)

  11. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    International Nuclear Information System (INIS)

    Vlachopoulou, Vassiliki; Antypas, Christos; Delis, Harry; Tzouras, Argyrios; Salvaras, Nikolaos; Kardamakis, Dimitrios; Panayiotakis, George

    2011-01-01

    Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases

  12. Monte Carlo dosimetry for synchrotron stereotactic radiotherapy of brain tumours

    International Nuclear Information System (INIS)

    Boudou, Caroline; Balosso, Jacques; Esteve, Francois; Elleaume, Helene

    2005-01-01

    A radiation dose enhancement can be obtained in brain tumours after infusion of an iodinated contrast agent and irradiation with kilovoltage x-rays in tomography mode. The aim of this study was to assess dosimetric properties of the synchrotron stereotactic radiotherapy technique applied to humans (SSR) for preparing clinical trials. We designed an interface for dose computation based on a Monte Carlo code (MCNPX). A patient head was constructed from computed tomography (CT) data and a tumour volume was modelled. Dose distributions were calculated in SSR configuration for various energy beam and iodine content in the target volume. From the calculations, it appears that the iodine-filled target (10 mg ml -1 ) can be efficiently irradiated by a monochromatic beam of energy ranging from 50 to 85 keV. This paper demonstrates the feasibility of stereotactic radiotherapy for treating deep-seated brain tumours with monoenergetic x-rays from a synchrotron

  13. Comparing conVEntional RadioTherapy with stereotactIC body radiotherapy in patients with spinAL metastases: study protocol for an randomized controlled trial following the cohort multiple randomized controlled trial design

    International Nuclear Information System (INIS)

    Velden, Joanne M. van der; Verkooijen, Helena M.; Seravalli, Enrica; Hes, Jochem; Gerlich, A. Sophie; Kasperts, Nicolien; Eppinga, Wietse S. C.; Verlaan, Jorrit-Jan; Vulpen, Marco van

    2016-01-01

    Standard radiotherapy is the treatment of first choice in patients with symptomatic spinal metastases, but is only moderately effective. Stereotactic body radiation therapy is increasingly used to treat spinal metastases, without randomized evidence of superiority over standard radiotherapy. The VERTICAL study aims to quantify the effect of stereotactic radiation therapy in patients with metastatic spinal disease. This study follows the ‘cohort multiple Randomized Controlled Trial’ design. The VERTICAL study is conducted within the PRESENT cohort. In PRESENT, all patients with bone metastases referred for radiation therapy are enrolled. For each patient, clinical and patient-reported outcomes are captured at baseline and at regular intervals during follow-up. In addition, patients give informed consent to be offered experimental interventions. Within PRESENT, 110 patients are identified as a sub cohort of eligible patients (i.e. patients with unirradiated painful, mechanically stable spinal metastases who are able to undergo stereotactic radiation therapy). After a protocol amendment, also patients with non-spinal bony metastases are eligible. From the sub cohort, a random selection of patients is offered stereotactic radiation therapy (n = 55), which patients may accept or refuse. Only patients accepting stereotactic radiation therapy sign informed consent for the VERTICAL trial. Non-selected patients (n = 55) receive standard radiotherapy, and are not aware of them serving as controls. Primary endpoint is pain response after three months. Data will be analyzed by intention to treat, complemented by instrumental variable analysis in case of substantial refusal of the stereotactic radiation therapy in the intervention arm. This study is designed to quantify the treatment response after (stereotactic) radiation therapy in patients with symptomatic spinal metastases. This is the first randomized study in palliative care following the cohort multiple Randomized

  14. Dosimetric effect of intrafraction tumor motion in phase gated lung stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Zhao Bo; Yang Yong; Li Tianfang; Li Xiang; Heron, Dwight E.; Huq, M. Saiful

    2012-01-01

    Purpose: A major concern for lung intensity modulated radiation therapy delivery is the deviation of actually delivered dose distribution from the planned one due to simultaneous movements of multileaf collimator (MLC) leaves and tumor. For gated lung stereotactic body radiotherapy treatment (SBRT), the situation becomes even more complicated because of SBRT's characteristics such as fewer fractions, smaller target volume, higher dose rate, and extended fractional treatment time. The purpose of this work is to investigate the dosimetric effect of intrafraction tumor motion during gated lung SBRT delivery by reconstructing the delivered dose distribution with real-time tumor motion considered. Methods: The tumor motion data were retrieved from six lung patients. Each of them received three fractions of stereotactic radiotherapy treatments with Cyberknife Synchrony (Accuray, Sunnyvale, CA). Phase gating through an external surrogate was simulated with a gating window of 5 mm. The resulting residual tumor motion curves during gating (beam-on) were retrieved. Planning target volume (PTV) was defined as physician-contoured clinical target volume (CTV) surrounded by an isotropic 5 mm margin. Each patient was prescribed with 60 Gy/3 fractions. The authors developed an algorithm to reconstruct the delivered dose with tumor motion. The DMLC segments, mainly leaf position and segment weighting factor, were recalculated according to the probability density function of tumor motion curve. The new DMLC sequence file was imported back to treatment planning system to reconstruct the dose distribution. Results: Half of the patients in the study group experienced PTV D95% deviation up to 26% for fractional dose and 14% for total dose. CTV mean dose dropped by 1% with tumor motion. Although CTV is almost covered by prescribed dose with 5 mm margin, qualitative comparison on the dose distributions reveals that CTV is on the verge of underdose. The discrepancy happens due to tumor

  15. CT simulation in stereotactic brain radiotherapy - analysis of isocenter reproducibility with mask fixation

    International Nuclear Information System (INIS)

    Willner, Jochen; Flentje, Michael; Bratengeier, Klaus

    1997-01-01

    Background and purpose: CT verification and measurement of isocenter deviation using repeated mask fixation in linac-based stereotactic high dose radiotherapy of brain metastases were performed in this study. Materials and methods: For stereotactic radiotherapy of brain metastases a commercial head mask fixation device based on thermoplastic materials (BrainLAB) was used. A two-step planning-treatment procedure was performed. Immediately before treatment the patient was relocated in the mask and a verification CT scan of the radiopaque marked isocenter was performed and if necessary its position was corrected. The verification procedure is described in detail. Twenty-two CT verifications in 16 patients were analyzed. Deviations were measured separately for each direction. A 3D-deviation vector was calculated. Additionally the average amount of deviation in each of the three dimensions was calculated. Results: The mean deviation and standard deviation (SD) of the isocenter was 0.4 mm (SD 1.5 mm) in the longitudinal direction, -0.1 mm (SD 1.8 mm) in the lateral direction and 0.1 mm (SD 1.2 mm) in the anterior-posterior direction. The mean three-dimensional distance (3D-vector) between the verified and the corrected isocenter was 2.4 mm (SD 1.3 mm). The average deviation (without consideration of direction) was 1.1 mm (SD 1.1 mm), 1.3 mm (SD 1.3 mm) and 0.8 mm (SD 0.9 mm) in the longitudinal, lateral and sagittal directions, respectively. No correlation was found between 3D-deviation and the distance of the isocenter from the reference plane nor between deviation and the position of metastases in the brain (central versus peripheral or between different lobes), or the date of treatment. Conclusion: Reproducibility of the isocenter using the presented mask fixation is in the range of positioning reproducibility reported for other non-invasive fixation devices for stereotactic brain treatment. Our results underline the importance of CT verification as a quality

  16. Stereotactic Radiotherapy for Adrenal Gland Metastases: University of Florence Experience

    International Nuclear Information System (INIS)

    Casamassima, Franco; Livi, Lorenzo; Masciullo, Stefano; Menichelli, Claudia; Masi, Laura; Meattini, Icro; Bonucci, Ivano; Agresti, Benedetta; Simontacchi, Gabriele; Doro, Raffaela

    2012-01-01

    Purpose: To evaluate a retrospective single-institution outcome after hypofractionated stereotactic body radiotherapy (SBRT) for adrenal metastases. Methods and Materials: Between February 2002 and December 2009, we treated 48 patients with SBRT for adrenal metastases. The median age of the patient population was 62.7 years (range, 43–77 years). In the majority of patients, the prescription dose was 36 Gy in 3 fractions (70% isodose, 17.14 Gy per fraction at the isocenter). Eight patients were treated with single-fraction stereotactic radiosurgery and forty patients with multi-fraction stereotactic radiotherapy. Results: Overall, the series of patients was followed up for a median of 16.2 months (range, 3–63 months). At the time of analysis, 20 patients were alive and 28 patients were dead. The 1- and 2-year actuarial overall survival rates were 39.7% and 14.5%, respectively. We recorded 48 distant failures and 2 local failures, with a median interval to local failure of 4.9 months. The actuarial 1-year disease control rate was 9%; the actuarial 1- and 2-year local control rate was 90%. Conclusion: Our retrospective study indicated that SBRT for the treatment of adrenal metastases represents a safe and effective option with a control rate of 90% at 2 years.

  17. Stereotactic lesioning for mental illness

    International Nuclear Information System (INIS)

    Kim, M.-C.; Lee, T.-K.

    2008-01-01

    The authors report stereotactically created lesioning by radiofrequency or Cyberknife radiosurgery for patients with mental illness. Since 1993, thirty-eight patients have undergone stereotactic psychosurgery for medically intractable mental illnesses. Two patients had aggressive behavior. Twenty-five patients suffered from Obsessive-Compulsive Disorder (OCD) and ten patients had depression. Another patient suffered from atypical psychosis. Bilateral amygdalotomy and subcaudate tractotomy were done for aggressive behavior. Limbic leucotomy or anterior cingulotomy was done for CCD and subcaudate tractotomy with or without cingulotomy was done for depression. In twenty-three patients, the lesions were made by a radiofrequency (RF) lesion generator. In fifteen cases, the lesions were made with Cyberknife Radiosurgery (CKRS). The Overt Aggression Scale (OAS) declined from 8 to 2 with clinical improvement during follow up period. With long-term follow up (meaning 57 months) in 25 OCDs, the mean Yale Brown Obsessive Compulsive Score (YBOCS) declined from 34 to 13 (n = 25). The Hamilton Depression scale (HAMD) for ten patients with depression declined from 38.5 to 10.5 (n = 10). There was no operative mortality and no significant morbidity except one case with transient urinary incontinence. Authors suggest that stereotactic psychosurgery by RF and CKRS could be a safe and effective means of treating some medically intractable mental illnesses. (author)

  18. Dose characteristics of in-house-built collimators for stereotactic radiotherapy with a linear accelerator

    International Nuclear Information System (INIS)

    Norrgaard, F. Stefan E.; Kulmala, Jarmo A.J.; Minn, Heikki R.I.; Sipilae, Petri M.

    1998-01-01

    Dose characteristics of a stereotactic radiotherapy unit based on a standard Varian Clinac 4/100 4 MV linear accelerator, in-house-built Lipowitz collimators and the SMART stereotactic radiotherapy treatment planning software have been determined. Beam collimation is constituted from the standard collimators of the linear accelerator and a tertiary collimation consisting of a replaceable divergent Lipowitz collimator. Four collimators with isocentre diameters of 15, 25, 35 and 45 mm, respectively, were constructed. Beam characteristics were measured in air, acrylic or water with ionization chamber, photon diode, electron diode, diamond detector and film. Monte Carlo simulation was also applied. The radiation leakage under the collimators was less than 1% at 50 mm depth in water. Specific beam characteristics for each collimator were imported to SMART and dose planning with five non-coplanar converging 140 deg. arcs separated by 36 deg. angles was performed for treatment of a RANDO phantom. Dose verification was made with TLD and radiochromic film. The in-house-built collimators were found to be suitable for stereotactic radiotherapy and patient treatments with this system are in progress. (author)

  19. Evaluation of time, attendance of medical staff, and resources during stereotactic radiotherapy/radiosurgery. QUIRO-DEGRO trial

    Energy Technology Data Exchange (ETDEWEB)

    Zabel-du Bois, A.; Milker-Zabel, S.; Debus, J. [Heidelberg Univ. (Germany). Dept. of Radiotherapy and Radiooncology; Henzel, M.; Engenhart-Cabillic, R. [Marburg Univ. (Germany). Dept. of Radiotherapy and Radiation Oncology; Popp, W. [Prime Networks AG, Basel (Switzerland); Sack, H. [Essen Univ. (Germany). Dept. of Radiation Oncology

    2012-09-15

    Background: The German Society of Radiation Oncology ('Deutsche Gesellschaft fuer Radioonkologie', DEGRO) initiated a multicenter trial to develop and evaluate adequate modules to assert core processes and subprocesses in radiotherapy. The aim of this prospective evaluation was to methodical assess the required resources (technical equipment and medical staff) for stereotactic radiotherapy/radiosurgery. Material and methods: At two radiotherapy centers of excellence (University Hospitals of Heidelberg and Marburg/Giessen), the manpower and time required for the implementation of intra- and extracranial stereotactic radiotherapy was prospectively collected consistently over a 3-month period. The data were collected using specifically developed process acquisition tools and standard forms and were evaluated using specific process analysis tools. Results: For intracranial (extracranial) fractionated stereotactic radiotherapy (FSRT) and radiosurgery (RS), a total of 1,925 (270) and 199 (36) records, respectively, could be evaluated. The approximate time needed to customize the immobilization device was median 37 min (89 min) for FRST and 31 min (26 min) for RS, for the contrast enhanced planning studies 22 and 27 min (25 and 28 min), for physical treatment planning 122 and 59 min (187 and 27 min), for the first and routine radiotherapy sessions for FSRT 40 and 13 min (58 and 31 min), respectively. The median time needed for the RS session was 58 min (45 min). The corresponding minimal manpower needed was 2 technicians for customization of the immobilization device, 2.5 technicians and 1 consultant for the contrast-enhanced planning studies, 1 consultant, 0.5 resident and 0.67 medical physics expert (MPE) for physical treatment planning, as well as 1 consultant, 0.5 resident, and 2.5 technicians for the first radiotherapy treatment and 2.33 technicians for routine radiotherapy sessions. Conclusion: For the first time, the resource requirements for a

  20. Neurosymptomatic carvenous sinus meningioma: a 15-years experience with fractionated stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Correa, Sebastião Francisco Miranda; Marta, Gustavo Nader; Teixeira, Manoel Jacobsen

    2014-01-01

    The tumor removal of Cavernous Sinus Meningiomas usually results in severe neurological deficits. Stereotactic radiosurgery (SRS) and fractionated Stereotactic radiotherapy (SRT) are advanced modalities of radiotherapy for treatment of patients with inoperable and symptomatic CSMs. The authors evaluated the long term symptomatology, the image findings, and the toxicity of patients with CSMs treated with SRS or SRT. From 1994 to 2009, 89 patients with symptomatic CSMs were treated with SRS or SRT. The indication was based on tumour volume and or proximity to the optic chiasm. The median single dose of SRS was 14 Gy, while the SRT total dose, ranged from 50.4 to 54 Gy fractionated in 1.8-2 Gy/dose. The median follow-up period lasted 73 months. The clinical and radiological improvement was the same despite the method of radiotherapy; 41.6% (SRS) and 48.3% (SRT) of patients treated. The disease-free survivals were 98.8%, 92.3% and 92.3%, in 5, 10, and 15 years, respectively. There was no statistical difference in relation to the symptoms and image findings between both methods. According to the Common Toxicity Criteria, 7% of the patients presented transient optic neuropathy during 3 months (grade 2) and recovered with dexamethasone, 2 patients had trigeminal neuropathy (grade 2) and improved rapidly, and one patient presented total occlusion of the internal carotid artery without neurological deficit (grade 2). Temporary lethargy and headache (grade 1) were the most frequent immediate complications. No severe complications occurred. Stereotactic Radiosurgery and fractionated Stereotactic Radiotherapy were equally safe and effective in the management of symptomatic CSMs

  1. Efficient and accurate stereotactic radiotherapy using flattening filter free beams and HexaPOD robotic tables

    DEFF Research Database (Denmark)

    Nielsen, Morten; Hansen, C. R.; Brink, C.

    2016-01-01

    Flattening filter free (FFF) high dose rate beam technique was introduced for brain stereotactic radiosurgery (SRS) and lung Stereotactic Body Radiotherapy (SBRT). Furthermore, a HexaPOD treatment table was introduced for the brain SRS to enable correction of rotational setup errors. 19 filter fl...

  2. The university of Florida frameless high-precision stereotactic radiotherapy system

    International Nuclear Information System (INIS)

    Bova, Francis J.; Buatti, John M.; Friedman, William A.; Mendenhall, William M.; Yang, Ching-Chong; Liu, Chihray

    1997-01-01

    Purpose: To develop and test a system for high precision fractionated stereotactic radiotherapy that separates immobilization and localization devices. Methods and Materials: Patient localization is achieved through detection and digital registration of an independent bite plate system. The bite plate is made and linked to a set of six infrared light emitting diodes (IRLEDs). These IRLEDs are detected by an infrared camera system that identifies the position of each IRLED within 0.1 to 0.15 mm. Calibration of the camera system defines isocenter and translational X, Y, and Z axes of the stereotactic radiosurgery subsystem and thereby digitally defines the virtual treatment room space in a computer linked to the camera system. Positions of the bite plate's IRLEDs are processed digitally using a computer algorithm so that positional differences between an actual bite plate position and a desired position can be resolved within 0.1 mm of translation (X, Y, and Z distance) and 0.1 degree of rotation. Furthermore, bite plate misalignment can be displayed digitally in real time with translational (x, y, and z) and rotational (roll, pitch, and yaw) parameters for an actual bite plate position. Immobilization is achieved by a custom head mold and thermal plastic mask linked by hook-and-loop fastener tape. The head holder system permits rotational and translational movements for daily treatment positioning based on the bite plate localization system. Initial testing of the localization system was performed on 20 patients treated with radiosurgery. The system was used to treat 11 patients with fractionated stereotactic radiotherapy. Results: Assessment of bite plate localization in radiosurgery patients revealed that the patient's bite plate could be positioned and repositioned within 0.5 ± 0.3 mm (standard deviation). After adjustments, the first 11 patients were treated with the bite plate repositioning error reduced to 0.2 ± 0.1 mm. Conclusions: High precision

  3. Effect of image-guided hypofractionated stereotactic radiotherapy on peripheral non-small-cell lung cancer

    Directory of Open Access Journals (Sweden)

    Wang SW

    2016-08-01

    Full Text Available Shu-wen Wang,1 Juan Ren,1 Yan-li Yan,2 Chao-fan Xue,2 Li Tan,2 Xiao-wei Ma2 1Department of Radiotherapy, First Affiliated Hospital of Xian Jiaotong University, 2Medical School of Xian Jiaotong University, Xi’an, Shaanxi, People’s Republic of China Abstract: The objective of this study was to compare the effects of image-guided hypofractionated radiotherapy and conventional fractionated radiotherapy on non-small-cell lung cancer (NSCLC. Fifty stage- and age-matched cases with NSCLC were randomly divided into two groups (A and B. There were 23 cases in group A and 27 cases in group B. Image-guided radiotherapy (IGRT and stereotactic radiotherapy were conjugately applied to the patients in group A. Group A patients underwent hypofractionated radiotherapy (6–8 Gy/time three times per week, with a total dose of 64–66 Gy; group B received conventional fractionated radiotherapy, with a total dose of 68–70 Gy five times per week. In group A, 1-year and 2-year local failure survival rate and 1-year local failure-free survival rate were significantly higher than in group B (P<0.05. The local failure rate (P<0.05 and distant metastasis rate (P>0.05 were lower in group A than in group B. The overall survival rate of group A was significantly higher than that of group B (P=0.03, and the survival rate at 1 year was 87% vs 63%, (P<0.05. The median survival time of group A was longer than that of group B. There was no significant difference in the incidence of complications between the two groups (P>0.05. Compared with conventional fractionated radiation therapy, image-guided hypofractionated stereotactic radiotherapy in NSCLC received better treatment efficacy and showed good tolerability. Keywords: non-small-cell lung cancer, hypofractionated radiotherapy, stereotactic radiotherapy, segmentation, intensity-modulated radiotherapy, image-guided radiation therapy technology

  4. Nelson's syndrome: single centre experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, Peter J; Williams, Janet R; Smee, Robert I

    2014-09-01

    Nelson's syndrome is a unique clinical phenomenon of growth of a pituitary adenoma following bilateral adrenalectomies for the control of Cushing's disease. Primary management is surgical, with limited effective medical therapies available. We report our own institution's series of this pathology managed with radiation: prior to 1990, 12 patients were managed with conventional radiotherapy, and between 1990 and 2007, five patients underwent stereotactic radiosurgery (SRS) and two patients fractionated stereotactic radiotherapy (FSRT), both using the linear accelerator (LINAC). Tumour control was equivocal, with two of the five SRS patients having a reduction in tumour volume, one patient remaining unchanged, and two patients having an increase in volume. In the FSRT group, one patient had a decrease in tumour volume whilst the other had an increase in volume. Treatment related morbidity was low. Nelson's syndrome is a challenging clinical scenario, with a highly variable response to radiation in our series. Copyright © 2014 Elsevier Ltd. All rights reserved.

  5. Hypofractionation Regimens for Stereotactic Radiotherapy for Large Brain Tumors

    International Nuclear Information System (INIS)

    Yuan Jiankui; Wang, Jian Z.; Lo, Simon; Grecula, John C.; Ammirati, Mario; Montebello, Joseph F.; Zhang Hualin; Gupta, Nilendu; Yuh, William T.C.; Mayr, Nina A.

    2008-01-01

    Purpose: To investigate equivalent regimens for hypofractionated stereotactic radiotherapy (HSRT) for brain tumor treatment and to provide dose-escalation guidance to maximize the tumor control within the normal brain tolerance. Methods and Materials: The linear-quadratic model, including the effect of nonuniform dose distributions, was used to evaluate the HSRT regimens. The α/β ratio was estimated using the Gammaknife stereotactic radiosurgery (GKSRS) and whole-brain radiotherapy experience for large brain tumors. The HSRT regimens were derived using two methods: (1) an equivalent tumor control approach, which matches the whole-brain radiotherapy experience for many fractions and merges it with the GKSRS data for few fractions; and (2) a normal-tissue tolerance approach, which takes advantages of the dose conformity and fractionation of HSRT to approach the maximal dose tolerance of the normal brain. Results: A plausible α/β ratio of 12 Gy for brain tumor and a volume parameter n of 0.23 for normal brain were derived from the GKSRS and whole-brain radiotherapy data. The HSRT prescription regimens for the isoeffect of tumor irradiation were calculated. The normal-brain equivalent uniform dose decreased as the number of fractions increased, because of the advantage of fractionation. The regimens for potential dose escalation of HSRT within the limits of normal-brain tolerance were derived. Conclusions: The designed hypofractionated regimens could be used as a preliminary guide for HSRT dose prescription for large brain tumors to mimic the GKSRS experience and for dose escalation trials. Clinical studies are necessary to further tune the model parameters and validate these regimens

  6. Image-Guided Radiotherapy via Daily Online Cone-Beam CT Substantially Reduces Margin Requirements for Stereotactic Lung Radiotherapy

    International Nuclear Information System (INIS)

    Grills, Inga S.; Hugo, Geoffrey; Kestin, Larry L.; Galerani, Ana Paula; Chao, K. Kenneth; Wloch, Jennifer; Yan Di

    2008-01-01

    Purpose: To determine treatment accuracy and margins for stereotactic lung radiotherapy with and without cone-beam CT (CBCT) image guidance. Methods and Materials: Acquired for the study were 308 CBCT of 24 patients with solitary peripheral lung tumors treated with stereotactic radiotherapy. Patients were immobilized in a stereotactic body frame (SBF) or alpha-cradle and treated with image guidance using daily CBCT. Four (T1) or five (T2/metastatic) 12-Gy fractions were prescribed to the planning target volume (PTV) edge. The PTV margin was ≥5 mm depending on a pretreatment estimate of tumor excursion. Initial daily setup was according to SBF coordinates or tattoos for alpha-cradle cases. A CBCT was performed and registered to the planning CT using soft tissue registration of the target. The initial setup error/precorrection position, was recorded for the superior-inferior, anterior-posterior, and medial-lateral directions. The couch was adjusted to correct the tumor positional error. A second CBCT verified tumor position after correction. Patients were treated in the corrected position after the residual errors were ≤2 mm. A final CBCT after treatment assessed intrafraction tumor displacement. Results: The precorrection systematic (Σ) and random errors (σ) for the population ranged from 2-3 mm for SBF and 2-6 mm for alpha-cradle patients; postcorrection errors ranged from 0.4-1.0 mm. Calculated population margins were 9 to 13 mm (SBF) and 10-14 mm (cradle) precorrection, 1-2 mm (SBF), and 2-3 mm (cradle) postcorrection, and 2-4 mm (SBF) and 2-5 mm (cradle) posttreatment. Conclusions: Setup for stereotactic lung radiotherapy using a SBF or alpha-cradle alone is suboptimal. CBCT image guidance significantly improves target positioning and substantially reduces required target margins and normal tissue irradiation

  7. A Retrospective Comparison of Robotic Stereotactic Body Radiotherapy and Three-Dimensional Conformal Radiotherapy for the Reirradiation of Locally Recurrent Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Ozyigit, Gokhan; Cengiz, Mustafa; Yazici, Gozde; Yildiz, Ferah; Gurkaynak, Murat; Zorlu, Faruk; Yildiz, Demet; Hosal, Sefik; Gullu, Ibrahim; Akyol, Fadil

    2011-01-01

    Purpose: We assessed therapeutic outcomes of reirradiation with robotic stereotactic radiotherapy (SBRT) for locally recurrent nasopharyngeal carcinoma (LRNPC) patients and compared those results with three-dimensional conformal radiotherapy (CRT) with or without brachytherapy (BRT). Methods and Materials: Treatment outcomes were evaluated retrospectively in 51 LRNPC patients receiving either robotic SBRT (24 patients) or CRT with or without BRT (27 patients) in our department. CRT was delivered with a 6-MV linear accelerator, and a median total reirradiation dose of 57 Gy in 2 Gy/day was given. Robotic SBRT was delivered with CyberKnife (Accuray, Sunnyvale, CA). Patients in the SBRT arm received 30 Gy over 5 consecutive days. We calculated actuarial local control and cancer-specific survival rates for the comparison of treatment outcomes in SBRT and CRT arms. The Common Terminology Criteria for Adverse Events v3.0 was used for toxicity evaluation. Results: The median follow-up was 24 months for all patients. Two-year actuarial local control rates were 82% and 80% for SBRT and CRT arms, respectively (p = 0.6). Two-year cancer-specific survival rates were 64% and 47% for the SBRT and CRT arms, respectively (p = 0.4). Serious late toxicities (Grade 3 and above) were observed in 21% of patients in the SBRT arm, whereas 48% of patients had serious toxicity in the CRT arm (p = 0.04). Fatal complications occurred in three patients (12.5%) of the SBRT arm, and four patients (14.8%) of the CRT arm (p = 0.8). T stage at recurrence was the only independent predictor for local control and survival. Conclusion: Our robotic SBRT protocol seems to be feasible and less toxic in terms of late effects compared with CRT arm for the reirradiation of LRNPC patients.

  8. Peripheral doses in patients undergoing Cyberknife treatment for intracranial lesions. A single centre experience

    Directory of Open Access Journals (Sweden)

    Vlachopoulou Vassiliki

    2011-11-01

    Full Text Available Abstract Background Stereotactic radiosurgery/radiotherapy procedures are known to deliver a very high dose per fraction, and thus, the corresponding peripheral dose could be a limiting factor for the long term surviving patients. The aim of this clinical study was to measure the peripheral dose delivered to patients undergoing intracranial Cyberknife treatment, using the MOSFET dosimeters. The influence of the supplemental shielding, the number of monitor units and the collimator size to the peripheral dose were investigated. Methods MOSFET dosimeters were placed in preselected anatomical regions of the patient undergoing Cyberknife treatment, namely the thyroid gland, the nipple, the umbilicus and the pubic symphysis. Results The mean peripheral doses before the supplemental shielding was added to the Cyberknife unit were 51.79 cGy, 13.31 cGy and 10.07 cGy while after the shielding upgrade they were 38.40 cGy, 10.94 cGy, and 8.69 cGy, in the thyroid gland, the umbilicus and the pubic symphysis, respectively. The increase of the collimator size corresponds to an increase of the PD and becomes less significant at larger distances, indicating that at these distances the PD is predominate due to the head leakage and collimator scatter. Conclusion Weighting the effect of the number of monitor units and the collimator size can be effectively used during the optimization procedure in order to choose the most suitable treatment plan that will deliver the maximum dose to the tumor, while being compatible with the dose constraints for the surrounding organs at risk. Attention is required in defining the thyroid gland as a structure of avoidance in the treatment plan especially in patients with benign diseases.

  9. SU-E-J-199: Evaluation of Motion Tracking Effects On Stereotactic Body Radiotherapy of Abdominal Targets

    Energy Technology Data Exchange (ETDEWEB)

    Monterroso, M; Dogan, N; Yang, Y [University Miami, Miami, FL (United States)

    2014-06-01

    Purpose: To evaluate the effects of respiratory motion on the delivered dose distribution of CyberKnife motion tracking-based stereotactic body radiotherapy (SBRT) of abdominal targets. Methods: Four patients (two pancreas and two liver, and all with 4DCT scans) were retrospectively evaluated. A plan (3D plan) using CyberKnife Synchrony was optimized on the end-exhale phase in the CyberKnife's MultiPlan treatment planning system (TPS), with 40Gy prescribed in 5 fractions. A 4D plan was then created following the 4D planning utility in the MultiPlan TPS, by recalculating dose from the 3D plan beams on all 4DCT phases, with the same prescribed isodose line. The other seven phases of the 4DCT were then deformably registered to the end-exhale phase for 4D dose summation. Doses to the target and organs at risk (OAR) were compared between 3D and 4D plans for each patient. The mean and maximum doses to duodenum, liver, spinal cord and kidneys, and doses to 5cc of duodenum, 700cc of liver, 0.25cc of spinal cord and 200cc of kidneys were used. Results: Target coverage in the 4D plans was about 1% higher for two patients and about 9% lower in the other two. OAR dose differences between 3D and 4D varied among structures, with doses as much as 8.26Gy lower or as much as 5.41Gy higher observed in the 4D plans. Conclusion: The delivered dose can be significantly different from the planned dose for both the target and OAR close to the target, which is caused by the relative geometry change while the beams chase the moving target. Studies will be performed on more patients in the future. The differences of motion tracking versus passive motion management with the use of internal target volumes will also be investigated.

  10. The progress in radiotherapy techniques and it's clinical implications

    International Nuclear Information System (INIS)

    Reinfuss, M.; Walasek, T.; Byrski, E.; Blecharz, P.

    2011-01-01

    Three modem radiotherapy techniques were introduced into clinical practice at the onset of the 21 st century - stereotactic radiation therapy (SRT), proton therapy and carbon-ion radiotherapy. Our paper summarizes the basic principles of physics, as well as the technical reqirements and clinical indications for those techniques. SRT is applied for intracranial diseases (arteriovenous malformations, acoustic nerve neuromas, brain metastases, skull base tumors) and in such cases it is referred to as stereotactic radiosurgery (SRS). Techniques used during SRS include GammaKnife, CyberKnife and dedicated linacs. SRT can also be applied for extracranial disease (non-small cell lung cancer, lung metastases, spinal and perispinal tumors, primary liver tumors, breast cancer, pancreatic tumors, prostate cancer, head and neck tumors) and in such cases it is referred to as stereotactic body radiation therapy (SBRT). Eye melanomas, skull base and cervical spine chordomas and chordosarcomas, as well as childhood neoplasms, are considered to be the classic indications for proton therapy. Clinical trials are currently conducted to investigate the usefulness of proton beam in therapy of non-small cell lung cancer, prostate cancer, head and neck tumors, primary liver and oesophageal cancer Carbon-ion radiotherapy is presumed to be more advantageous than proton therapy because of its higher relative biological effectiveness (RBE) and possibility of real-time control of the irradiated volume under PET visualization. The basic indications for carbon-ion therapy are salivary glands neoplasms, selected types of soft tissue and bone sarcomas, skull base chordomas and chordosarcomas, paranasal sinus neoplasms, primary liver cancers and inoperable rectal adenocarcinoma recurrences. (authors)

  11. Cushing's disease: a single centre's experience using the linear accelerator (LINAC) for stereotactic radiosurgery and fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Wilson, P J; Williams, J R; Smee, R I

    2014-01-01

    Cushing's disease is hypercortisolaemia secondary to an adrenocorticotrophic hormone secreting pituitary adenoma. Primary management is almost always surgical, with limited effective medical interventions available. Adjuvant therapy in the form of radiation is gaining popularity, with the bulk of the literature related to the Gamma Knife. We present the results from our own institution using the linear accelerator (LINAC) since 1990. Thirty-six patients who underwent stereotactic radiosurgery (SRS), one patient who underwent fractionated stereotactic radiotherapy (FSRT) and for the purposes of comparison, 13 patients who had undergone conventional radiotherapy prior to 1990, were included in the analysis. Serum cortisol levels improved in nine of 36 (25%) SRS patients and 24 hour urinary free cortisol levels improved in 13 of 36 patients (36.1%). Tumour volume control was excellent in the SRS group with deterioration in only one patient (3%). The patient who underwent FSRT had a highly aggressive tumour refractory to radiation. Published by Elsevier Ltd.

  12. Stereotactic body radiotherapy for renal cell cancer and pancreatic cancer. Literature review and practice recommendations of the DEGRO Working Group on Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Panje, Cedric; Andratschke, Nikolaus; Guckenberger, Matthias; Brunner, Thomas B.; Niyazi, Maximilian

    2016-01-01

    This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a literature review and practice recommendations for stereotactic body radiotherapy (SBRT) of primary renal cell cancer and primary pancreatic cancer. A literature search on SBRT for both renal cancer and pancreatic cancer was performed with focus on prospective trials and technical aspects for clinical implementation. Data on renal and pancreatic SBRT are limited, but show promising rates of local control for both treatment sites. For pancreatic cancer, fractionated SBRT should be preferred to single-dose treatment to reduce the risk of gastrointestinal toxicity. Motion-compensation strategies and image guidance are paramount for safe SBRT delivery in both tumor entities. SBRT for renal cancer and pancreatic cancer have been successfully evaluated in phase I and phase II trials. Pancreatic SBRT should be practiced carefully and only within prospective protocols due to the risk of severe gastrointestinal toxicity. SBRT for primary renal cell cancer appears a viable option for medically inoperable patients but future research needs to better define patient selection criteria and the detailed practice of SBRT. (orig.) [de

  13. Stereotactic radiotherapy and radiosurgery in pediatric patients: analysis of indications and outcome

    DEFF Research Database (Denmark)

    Mirza, Bilal; Mønsted, Anne; Jensen, Josephine Harding

    2010-01-01

    We describe indications, outcomes, and risk profiles of fractionated stereotactic radiotherapy (SRT) and single fraction "radiosurgery" (SRS) in pediatric patients compared to the adult population and evaluate the causal role of SRS and SRT in inducing new neurological complications....

  14. Stereotactic radiotherapy in oligometastatic cancer.

    Science.gov (United States)

    Kennedy, Thomas A C; Corkum, Mark T; Louie, Alexander V

    2017-09-01

    Oligometastatic cancer describes a disease state somewhere between localized and metastatic cancer. Proposed definitions of oligometastatic disease have typically used a cut-off of five or fewer sites of disease. Treatment of oligometastatic disease should have the goal of long-term local control, and in selected cases, disease remission. While several retrospective cohorts argue for surgical excision of limited metastases (metastasectomy) as the preferred treatment option for several clinical indications, limited randomized data exists for treating oligometastases. Alternatively, stereotactic ablative radiotherapy (SABR) is a radiotherapy technique that combines high radiation doses per fraction with precision targeting with the goal of achieving long-term local control of treated sites. Published cohort studies of SABR have demonstrated excellent local control rates of 70-90% in oligometastatic disease, with long-term survival in some series approaching 20-40%. A recent randomized phase 2 clinical trial by Gomez et al. demonstrated significantly improved progression free survival with aggressive consolidative therapy (surgery, radiotherapy ± chemotherapy or SABR) in oli-gometastatic non-small cell lung cancer (NSCLC). As additional randomized controlled trials are ongoing to determine the efficacy of SABR in oligometastatic disease, SABR is increasingly being used within routine clinical practice. This review article aims to sum-marize the history and current paradigm of the oligometastatic state, review recently pub-lished literature of SABR in oligometastatic cancer and discuss ongoing trials and future directions in this context.

  15. CyberKnife Boost for Patients with Cervical Cancer Unable to Undergo Brachytherapy

    International Nuclear Information System (INIS)

    Haas, Jonathan Andrew; Witten, Matthew R.; Clancey, Owen; Episcopia, Karen; Accordino, Diane; Chalas, Eva

    2012-01-01

    Standard radiation therapy for patients undergoing primary chemosensitized radiation for carcinomas of the cervix usually consists of external beam radiation followed by an intracavitary brachytherapy boost. On occasion, the brachytherapy boost cannot be performed due to unfavorable anatomy or because of coexisting medical conditions. We examined the safety and efficacy of using CyberKnife stereotactic body radiotherapy (SBRT) as a boost to the cervix after external beam radiation in those patients unable to have brachytherapy to give a more effective dose to the cervix than with conventional external beam radiation alone. Six consecutive patients with anatomic or medical conditions precluding a tandem and ovoid boost were treated with combined external beam radiation and CyberKnife boost to the cervix. Five patients received 45 Gy to the pelvis with serial intensity-modulated radiation therapy boost to the uterus and cervix to a dose of 61.2 Gy. These five patients received an SBRT boost to the cervix to a dose of 20 Gy in five fractions of 4 Gy each. One patient was treated to the pelvis to a dose of 45 Gy with an external beam boost to the uterus and cervix to a dose of 50.4 Gy. This patient received an SBRT boost to the cervix to a dose of 19.5 Gy in three fractions of 6.5 Gy. Five percent volumes of the bladder and rectum were kept to ≤75 Gy in all patients (i.e., V75 Gy ≤ 5%). All of the patients remain locally controlled with no evidence of disease following treatment. Grade 1 diarrhea occurred in 4/6 patients during the conventional external beam radiation. There has been no grade 3 or 4 rectal or bladder toxicity. There were no toxicities observed following SBRT boost. At a median follow-up of 14 months, CyberKnife radiosurgical boost is well tolerated and efficacious in providing a boost to patients with cervix cancer who are unable to undergo brachytherapy boost. Further follow-up is required to see if these results remain durable.

  16. Stereotactic radiotherapy for non-small cell lung cancer: From concept to clinical reality. 2011 update; Radiotherapie stereotaxique des cancers broncho-pulmonaires non a petites cellules: d'un concept a une realite clinique. Actualites en 2011

    Energy Technology Data Exchange (ETDEWEB)

    Girard, N. [Service de pneumologie, hopital Louis-Pradel, hospices civils de Lyon, 28, avenue du Doyen-Jean-Lepine, 69500 Bron (France); UMR 754, universite Claude-Bernard Lyon 1, 43, boulevard du 11-Novembre-1918, 69622 Villeurbanne cedex (France); Mornex, F. [Departement de radiotherapie oncologie, centre hospitalier Lyon-Sud, 165, chemin du Grand-Revoyet, 69495 Pierre-Benite cedex (France); EA 37-38, universite Claude-Bernard Lyon 1, 43, boulevard du 11-Novembre-1918, 69622 Villeurbanne cedex (France)

    2011-10-15

    Only 60% of patients with early-stage non-small cell lung cancer (NSCLC), a priori bearing a favorable prognosis, undergo radical resection because of the very frequent co-morbidities occurring in smokers, precluding surgery to be safely performed. Stereotactic radiotherapy consists of the use of multiple radiation micro-beams, allowing high doses of radiation to be delivered to the tumour (ranging from 7.5 to 20 Gy per fraction) in a small number of fractions (one to eight on average). Several studies with long-term follow-up are now available, showing the effectiveness of stereotactic radiotherapy to control stage I/II non-small cell lung cancer in medically inoperable patients. Local control rates are consistently reported to be above 95% with a median survival of 34 to 45 months. Because of these excellent results, stereotactic radiation therapy is now being evaluated in operable patients in several randomized trials with a surgical arm. Ultimately, the efficacy of stereotactic radiotherapy in early-stage tumours leads to hypothesize that it may represent an opportunity for locally-advanced tumors. The specific toxicities of stereotactic radiotherapy mostly correspond to radiation-induced chest wall side effects, especially for peripheral tumours. The use of adapted fractionation schemes has made feasible the use of stereotactic radiotherapy to treat proximal tumours. Overall, from a technical concept to the availability of specific treatment devices and the publication of clinical results, stereotactic radiotherapy represents a model of implementation in thoracic oncology. (authors)

  17. Direct tumor in vivo dosimetry in highly-conformal radiotherapy: A feasibility study of implantable MOSFETs for hypofractionated extracranial treatments using the Cyberknife system

    International Nuclear Information System (INIS)

    Scalchi, Paolo; Righetto, Roberto; Cavedon, Carlo; Francescon, Paolo; Colombo, Federico

    2010-01-01

    Purpose: In highly-conformal radiotherapy, due to the complexity of both beam configurations and dose distributions, traditional in vivo dosimetry is unpractical or even impossible. The ideal dosimeter would be implanted inside the planning treatment volume so that it can directly measure the total delivered dose during each fraction with no additional uncertainty due to calculation models. The aim of this work is to verify if implantable metal oxide semiconductors field effect transistors (MOSFETs) can achieve a sufficient degree of dosimetric accuracy when used inside extracranial targets undergoing radiotherapy treatments using the Cyberknife system. Methods: Based on the preliminary findings of this study, new prototypes for high dose fractionations were developed to reduce the time dependence for long treatment delivery times. These dosimeters were recently cleared and are marketed as DVS-HFT. Multiple measurements were performed using both Virtual Water and water phantoms to characterize implantable MOSFETs under the Cyberknife beams, and included the reference-dosimetry consistency, the dependence of the response on the collimator size, on the daily delivered dose, and the time irradiation modality. Finally a Cyberknife prostate treatment simulation using a body phantom was conducted, and both MOSFET and ionization readings were compared to Monte Carlo calculations. The feasibility analysis was conducted based on the ratios of the absorbed dose divided by the dose reading, named as ''further calibration factor'' (FCF). Results: The average FCFs resulted to be 0.98 for the collimator dependence test, and about 1.00 for the reference-dosimetry test, the dose-dependence test, and the time-dependence test. The average FCF of the prostate treatment simulation test was 0.99. Conclusions: The obtained results are well within DVS specifications, that is, the factory calibration is still valid for such kind of treatments using the Cyberknife system, with no need of

  18. Optimization of the primary collimator settings for fractionated IMRT stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tobler, Matt; Leavitt, Dennis D.; Watson, Gordon

    2004-01-01

    Advances in field-shaping techniques for stereotactic radiosurgery/radiotherapy have allowed dynamic adjustment of field shape with gantry rotation (dynamic conformal arc) in an effort to minimize dose to critical structures. Recent work evaluated the potential for increased sparing of dose to normal tissues when the primary collimator setting is optimized to only the size necessary to cover the largest shape of the dynamic micro multi leaf field. Intensity-modulated radiotherapy (IMRT) is now a treatment option for patients receiving stereotactic radiotherapy treatments. This multisegmentation of the dose delivered through multiple fixed treatment fields provides for delivery of uniform dose to the tumor volume while allowing sparing of critical structures, particularly for patients whose tumor volumes are less suited for rotational treatment. For these segmented fields, the total number of monitor units (MUs) delivered may be much greater than the number of MUs required if dose delivery occurred through an unmodulated treatment field. As a result, undesired dose delivered, as leakage through the leaves to tissues outside the area of interest, will be proportionally increased. This work will evaluate the role of optimization of the primary collimator setting for these IMRT treatment fields, and compare these results to treatment fields where the primary collimator settings have not been optimized

  19. Optimization of Stereotactic Radiotherapy Treatment Delivery Technique for Base-Of-Skull Meningiomas

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Candish, Charles; Vollans, Emily; Gete, Ermias; Lee, Richard; Martin, Monty; Ma, Roy; McKenzie, Michael

    2008-01-01

    This study compares static conformal field (CF), intensity modulated radiotherapy (IMRT), and dynamic arcs (DA) for the stereotactic radiotherapy of base-of-skull meningiomas. Twenty-one cases of base-of-skull meningioma (median planning target volume [PTV] = 21.3 cm 3 ) previously treated with stereotactic radiotherapy were replanned with each technique. The plans were compared for Radiation Therapy Oncology Group conformity index (CI) and homogeneity index (HI), and doses to normal structures at 6 dose values from 50.4 Gy to 5.6 Gy. The mean CI was 1.75 (CF), 1.75 (DA), and 1.66 (IMRT) (p 3 , the CI (IMRT) was always superior to CI (DA) and CI (CF). At PTV sizes below 25 cm 3 , there was no significant difference in CI between each technique. There was no significant difference in HI between plans. The total volume of normal tissue receiving 50.4, 44.8, and 5.6 Gy was significantly lower when comparing IMRT to CF and DA plans (p 3 , due to improved conformity and normal tissue sparing, in particular for the brain stem and ipsilateral temporal lobe

  20. Stereotactic radiotherapy for patients with metallic implants on vertebral body: A dosimetric comparison

    OpenAIRE

    Guzle Adas, Yasemin; Yazici, Omer; Kekilli, Esra; Kiran, Ferat

    2018-01-01

    Objective: Metallic implants have impacts on dose distribution of radiotherapy. Our purpose is evaluating impact of metallic implants with different dose calculation algorithms on dose distribution. Material and Methods: Two patients with metallic implants on vertebral body were included in this study. They were treated with stereotactic radiotherapy. The data of the patients were retrospectively re-calculated with different TPSs and calculation algorithms. Ray-Tracing (Ry-Tc), Mont...

  1. Fractionated stereotactic radiotherapy for craniopharyngiomas

    International Nuclear Information System (INIS)

    Schulz-Ertner, Daniela; Frank, Claudia; Herfarth, Klaus K.; Rhein, Bernhard; Wannenmacher, Michael; Debus, Juergen

    2002-01-01

    Purpose: To investigate outcome and toxicity after fractionated stereotactic radiation therapy (FSRT) in patients with craniopharyngiomas. Methods and Materials: Twenty-six patients with craniopharyngiomas were treated with FSRT between May 1989 and February 2001. Median age was 33.5 years (range: 5-57 years). Nine patients received FSRT after surgery as primary treatment, and 17 patients were irradiated for recurrent tumor or progressive growth after initial surgery. Median target dose was 52.2 Gy (range: 50.0-57.6 Gy) with conventional fractionation. Follow-up included MRI and neurologic, ophthalmologic, and endocrinologic examinations. Results: The median follow-up was 43 months (range: 7-143 months). The actuarial local control rate and actuarial overall survival rates were 100% and 100%, respectively, at 5 years and 100% and 83%, respectively, at 10 years. Four patients showed complete response, 14 patients showed partial response, and 8 patients remained stable. In 5 patients, vision improved after radiation therapy. Acute toxicity was mild. One patient required cyst drainage 3 months after radiotherapy. Late toxicity after radiotherapy included impairment of hormone function in 3 out of 18 patients at risk. We did not observe any vision impairment, radionecrosis, or secondary malignancies. Conclusions: FSRT is effective and safe in the treatment of cystic craniopharyngiomas. Toxicity is extremely low using this conformal technique

  2. Phase II study on stereotactic body radiotherapy of colorectal metastases

    DEFF Research Database (Denmark)

    Høyer, Morten; Roed, Henrik; Traberg Hansen, Anders

    2006-01-01

    Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT) in the tre......Surgical resection provides long term survival in approximately 30% of patients with colorectal carcinoma (CRC) liver metastases. However, only a limited number of patients with CRC-metastases are amendable for surgery. We have tested the effect of stereotactic body radiotherapy (SBRT......) in the treatment of inoperable patients with CRC-metastases. Sixty-four patients with a total number of 141 CRC-metastases in the liver (n = 44), lung (n = 12), lymph nodes (n = 3), suprarenal gland (n = 1) or two organs (n = 4) were treated with SBRT with a central dose of 15 Gy x 3 within 5-8 days. Median follow...... due to hepatic failure, one patient was operated for a colonic perforation and two patients were conservatively treated for duodenal ulcerations. Beside these, only moderate toxicities such as nausea, diarrhoea and skin reactions were observed. SBRT in patients with inoperable CRC-metastases resulted...

  3. Extracranial stereotactic radiotherapy: Evaluation of PTV coverage and dose conformity

    International Nuclear Information System (INIS)

    Haedinger, U.; Thiele, W.; Wulf, J.

    2002-01-01

    During the past few years the concept of cranial sterotactic radiotherapy has been successfully extended to extracranial tumoral targets. In our department, hypofractionated treatment of tumours in lung, liver, abdomen, and pelvis is performed in the Stereotactic Body Frame (ELEKTA Instrument AB) since 1997. We present the evaluation of 63 consecutively treated targets (22 lung, 21 liver, 20 abdomen/pelvis) in 58 patients with respect to dose coverage of the planning target volume (PTV) as well as conformity of the dose distribution. The mean PTV coverage was found to be 96.3%±2.3% (lung), 95.0%±4.5% (liver), and 92.1%±5.2% (abdomen/pelvis). For the so-called conformation number we obtained values of 0.73±0.09 (lung), 0.77±0.10 (liver), and 0.70±0.08 (abdomen/pelvis). The results show that highly conformal treatment techniques can be applied also in extracranial stereotactic radiotherapy. This is primarily due to the relatively simple geometrical shape of most of the targets. Especially lung and liver targets turned out to be approximately spherically/cylindrically shaped, so that the dose distribution can be easily tailored by rotational fields. (orig.) [de

  4. Dose profile measurements during respiratory-gated lung stereotactic radiotherapy: A phantom study

    International Nuclear Information System (INIS)

    Jong, W L; Ung, N M; Wong, J H D; Ng, K H

    2016-01-01

    During stereotactic body radiotherapy, high radiation dose (∼60 Gy) is delivered to the tumour in small fractionation regime. In this study, the dosimetric characteristics were studied using radiochromic film during respiratory-gated and non-gated lung stereotactic body radiotherapy (SBRT). Specifically, the effect of respiratory cycle and amplitude, as well as gating window on the dosimetry were studied. In this study, the dose profiles along the irradiated area were measured. The dose profiles for respiratory-gated radiation delivery with different respiratory or tumour motion amplitudes, gating windows and respiratory time per cycle were in agreement with static radiation delivery. The respiratory gating system was able to deliver the radiation dose accurately (±1.05 mm) in the longitudinal direction. Although the treatment time for respiratory-gated SBRT was prolonged, this approach can potentially reduce the margin for internal tumour volume without compromising the tumour coverage. In addition, the normal tissue sparing effect can be improved. (paper)

  5. Patient reported outcomes following stereotactic ablative radiotherapy or surgery for stage IA non-small-cell lung cancer : Results from the ROSEL multicenter randomized trial

    NARCIS (Netherlands)

    Louie, Alexander V.; van Werkhoven, Erik; Chen, Hanbo; Smit, Egbert F.; Paul, Marinus A.; Widder, Joachim; Groen, Harry J. M.; van den Borne, Ben E. E. M.; De Jaeger, Katrien; Slotman, Ben J.; Senan, Suresh

    2015-01-01

    We report quality of life and indirect costs from patient reported outcomes from the ROSEL randomized control trial comparing stereotactic ablative radiotherapy (SABR, also known as stereotactic body radiotherapy or SBRT) versus surgical resection for medically operable stage IA non-small cell lung

  6. Treatment of Sarcoma Lung Metastases with Stereotactic Body Radiotherapy

    Directory of Open Access Journals (Sweden)

    Adam D. Lindsay

    2018-01-01

    Full Text Available Background. The most common site of sarcoma metastasis is the lung. Surgical resection of pulmonary metastases and chemotherapy are treatment options that have been employed, but many patients are poor candidates for these treatments for multiple host or tumor-related reasons. In this group of patients, radiation might provide a less morbid treatment alternative. We sought to evaluate the efficacy of radiotherapy in the treatment of metastatic sarcoma to the lung. Methods. Stereotactic body radiotherapy (SBRT was used to treat 117 pulmonary metastases in 44 patients. Patients were followed with serial computed tomography imaging of the chest. The primary endpoint was failure of control of a pulmonary lesion as measured by continued growth. Radiation-associated complications were recorded. Results. The majority of patients (84% received a total dose of 50 Gy per metastatic nodule utilizing an image-guided SBRT technique. The median interval follow-up was 14.2 months (range 1.6–98.6 months. Overall survival was 82% at two years and 50% at five years. Of 117 metastatic nodules treated, six nodules showed failure of treatment (95% control rate. Twenty patients (27% developed new metastatic lesions and underwent further SBRT. The side effects of SBRT included transient radiation pneumonitis n=6, cough n=2, rib fracture n=1, chronic pain n=1, dermatitis n=1, and dyspnea n=1. Conclusion. Stereotactic body radiotherapy is an effective and safe treatment for the ablation of pulmonary metastasis from sarcoma. Further work is needed to evaluate the optimal role of SBRT relative to surgery or chemotherapy for treatment of metastatic sarcoma.

  7. Analysis of Electronic Densities and Integrated Doses in Multiform Glioblastomas Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Baron-Aznar, C.; Moreno-Jimenez, S.; Celis, M. A.; Ballesteros-Zebadua, P.; Larraga-Gutierrez, J. M.

    2008-01-01

    Integrated dose is the total energy delivered in a radiotherapy target. This physical parameter could be a predictor for complications such as brain edema and radionecrosis after stereotactic radiotherapy treatments for brain tumors. Integrated Dose depends on the tissue density and volume. Using CT patients images from the National Institute of Neurology and Neurosurgery and BrainScan(c) software, this work presents the mean density of 21 multiform glioblastomas, comparative results for normal tissue and estimated integrated dose for each case. The relationship between integrated dose and the probability of complications is discussed

  8. 4D imaging for target definition in stereotactic radiotherapy for lung cancer.

    Science.gov (United States)

    Slotman, Ben J; Lagerwaard, Frank J; Senan, Suresh

    2006-01-01

    Stereotactic radiotherapy of Stage I lung tumors has been reported to result in high local control rates that are far superior to those obtained with conventional radiotherapy techniques, and which approach those achieved with primary surgery. Breathing-induced motion of tumor and target tissues is an important issue in this technique and careful attention should be paid to the contouring and the generation of individualized margins. We describe our experience with the use of 4DCT scanning for this group of patients, the use of post-processing tools and the potential benefits of respiratory gating.

  9. Stereotactic imaging for radiotherapy: accuracy of CT, MRI, PET and SPECT

    International Nuclear Information System (INIS)

    Karger, Christian P; Hipp, Peter; Henze, Marcus; Echner, Gernot; Hoess, Angelika; Schad, Lothar; Hartmann, Guenther H

    2003-01-01

    CT, MRI, PET and SPECT provide complementary information for treatment planning in stereotactic radiotherapy. Stereotactic correlation of these images requires commissioning tests to confirm the localization accuracy of each modality. A phantom was developed to measure the accuracy of stereotactic localization for CT, MRI, PET and SPECT in the head and neck region. To this end, the stereotactically measured coordinates of structures within the phantom were compared with their mechanically defined coordinates. For MRI, PET and SPECT, measurements were performed using two different devices. For MRI, T1- and T2-weighted imaging sequences were applied. For each measurement, the mean radial deviation in space between the stereotactically measured and mechanically defined position of target points was determined. For CT, the mean radial deviation was 0.4 ± 0.2 mm. For MRI, the mean deviations ranged between 0.7 ± 0.2 mm and 1.4 ± 0.5 mm, depending on the MRI device and the imaging sequence. For PET, mean deviations of 1.1 ± 0.5 mm and 2.4 ± 0.3 mm were obtained. The mean deviations for SPECT were 1.6 ± 0.5 mm and 2.0 ± 0.6 mm. The phantom is well suited to determine the accuracy of stereotactic localization with CT, MRI, PET and SPECT in the head and neck region. The obtained accuracy is well below the physical resolution for CT, PET and SPECT, and of comparable magnitude for MRI. Since the localization accuracy may be device dependent, results obtained at one device cannot be generalized to others

  10. Re-irradiation: Outcome, cumulative dose and toxicity in patients retreated with stereotactic radiotherapy in the abdominal or pelvic region

    NARCIS (Netherlands)

    H. Abusaris (Huda); M.S. Hoogeman (Mischa); J.J.M.E. Nuyttens (Joost)

    2012-01-01

    textabstractThe purpose of the present study was to explore the outcome, cumulative dose in tumor and organs at risk and toxicity after extra-cranial stereotactic re-irradiation. Twenty-seven patients were evaluated who had been re-irradiated with stereotactic body radiotherapy (SBRT) after

  11. Accuracy of out-of-field dose calculation of tomotherapy and Cyberknife treatment planning systems. A dosimetric study

    International Nuclear Information System (INIS)

    Schneider, Uwe; Hirslanden Medical Center, Aarau; Haelg, Roger A.; Hartmann, Matthias; Mack, Andreas; Storelli, Fabrizio; Besserer, Juergen; Joosten, Andreas; Moeckli, Raphael

    2014-01-01

    Purpose: Late toxicities such as second cancer induction become more important as treatment outcome improves. Often the dose distribution calculated with a commercial treatment planning system (TPS) is used to estimate radiation carcinogenesis for the radiotherapy patient. However, for locations beyond the treatment field borders, the accuracy is not well known. The aim of this study was to perform detailed out-of-field-measurements for a typical radiotherapy treatment plan administered with a Cyberknife and a Tomotherapy machine and to compare the measurements to the predictions of the TPS. Materials and methods: Individually calibrated thermoluminescent dosimeters were used to measure absorbed dose in an anthropomorphic phantom at 184 locations. The measured dose distributions from 6 MV intensity-modulated treatment beams for CyberKnife and TomoTherapy machines were compared to the dose calculations from the TPS. Results: The TPS are underestimating the dose far away from the target volume. Quantitatively the Cyberknife underestimates the dose at 40 cm from the PTV border by a factor of 60, the Tomotherapy TPS by a factor of two. If a 50% dose uncertainty is accepted, the Cyberknife TPS can predict doses down to approximately 10 mGy/treatment Gy, the Tomotherapy-TPS down to 0.75 mGy/treatment Gy. The Cyberknife TPS can then be used up to 10 cm from the PTV border the Tomotherapy up to 35 cm. Conclusions: We determined that the Cyberknife and Tomotherapy TPS underestimate substantially the doses far away from the treated volume. It is recommended not to use out-of-field doses from the Cyberknife TPS for applications like modeling of second cancer induction. The Tomotherapy TPS can be used up to 35 cm from the PTV border (for a 390 cm 3 large PTV). (orig.)

  12. Stereotactic Body Radiotherapy for Centrally Located Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yuming WAN

    2018-05-01

    Full Text Available A few study has proven that about 90% of local control rates might be benefit from stereotactic body radiotherapy (SBRT for patients with medically inoperable stage I non-small cell lung cancer (NSCLC, it is reported SBRT associated overall survival and tumor specific survival is comparable with those treated with surgery. SBRT has been accepted as the first line treatment for inoperable patients with peripheral located stage I NSCLC. However, the role of SBRT in centrally located lesions is controversial for potential toxic effects from the adjacent anatomical structure. This paper will review the definition, indication, dose regimens, dose-volume constraints for organs at risk, radiation technology, treatment side effect of centrally located NSCLC treated with SBRT and stereotactic body proton therapy.

  13. Inter- and intrafractional movement of the tumour in extracranial stereotactic radiotherapy of NSCLC

    DEFF Research Database (Denmark)

    Jensen, Henrik R; Hansen, Olfred; Hjelm-Hansen, Mogens

    2008-01-01

    where given a stereotactic treatment. The patients were scanned with normal and uncoached respiration without use of abdominal compression. Each patient had CT-scans performed at four occasions throughout the treatment: As part of the CT-simulation and before the three radiotherapy treatments. At every...... frame were LR: 1.5 mm, AP: 1.1 mm and CC: 1.7 mm (1 SD). DISCUSSION AND CONCLUSIONS: Consecutive CT scans can be used to evaluate the respiration induced tumour movement. For patients immobilized in a stereotactic body frame, large movements of the tumour are rarely seen within the lung...

  14. Endocrine and visual function after fractionated stereotactic radiotherapy of perioptic tumors

    Energy Technology Data Exchange (ETDEWEB)

    Kocher, M.; Semrau, R.; Mueller, R.P. [Universitaetsklinikum Koeln (Germany). Klinik und Poliklinik fuer Strahlentherapie; Treuer, H.; Hoevels, M.; Sturm, V. [Koeln Univ. (Germany). Dept. of Stereotaxy and Functional Neurosurgery

    2013-02-15

    Purpose: To find out whether the use of stereotactic techniques for fractionated radiotherapy reduces toxicity to the endocrine and visual system in patients with benign perioptic tumors. Patients and methods: From 1993 to 2009, 29 patients were treated with fractionated stereotactic radiotherapy. The most frequent tumor types were grade I meningioma (n = 11) and pituitary adenoma (n = 10, 7 nonfunctioning, 3 growth hormone-producing). Patients were immobilized with the GTC frame (Radionics, USA) and the planning target volume (PTV; median 24.7, 4.6-58.6 ml) was irradiated with a total dose of 52.2 Gy (range, 45.0-55.8 Gy) in 1.8-Gy fractions using a linear accelerator (6 MeV photons) equipped with a micro-multileaf collimator. Maximum doses to the optic system and pituitary gland were 53.4 Gy (range, 11.5-57.6 Gy) and 53.6 Gy (range, 12.0-57.9 Gy). Results: Median follow-up was 45 months (range, 10-105 months). Local control was achieved in all but 1 patient (actuarial rate 92% at 5 years and 10 years). In 9 of 29 patients (31%), partial remission was observed (actuarial response rate 40% at 5 years and 10 years). In 4 of 26 patients (15%) with at least partial pituitary function, new hormonal deficits developed (actuarial rate 21% at 5 years and 10 years). This rate was significantly higher in patients treated for a larger PTV ( 25 ml: 0% vs. 42% at 5 years and 10 years, p = 0.028). Visual function improved in 4 of 15 patients (27%) who had prior impairment. None of the patients developed treatment-related optic neuropathy, but 2 patients experienced new disease-related visual deficits. Conclusion: Fractionated stereotactic radiotherapy for benign tumors of the perioptic and sellar region results in satisfactory response and local control rates and does not affect the visual system. The assumption that patients can be spared hypophyseal insufficiency only holds for small tumors. (orig.)

  15. Endocrine and visual function after fractionated stereotactic radiotherapy of perioptic tumors

    International Nuclear Information System (INIS)

    Kocher, M.; Semrau, R.; Mueller, R.P.; Treuer, H.; Hoevels, M.; Sturm, V.

    2013-01-01

    Purpose: To find out whether the use of stereotactic techniques for fractionated radiotherapy reduces toxicity to the endocrine and visual system in patients with benign perioptic tumors. Patients and methods: From 1993 to 2009, 29 patients were treated with fractionated stereotactic radiotherapy. The most frequent tumor types were grade I meningioma (n = 11) and pituitary adenoma (n = 10, 7 nonfunctioning, 3 growth hormone-producing). Patients were immobilized with the GTC frame (Radionics, USA) and the planning target volume (PTV; median 24.7, 4.6-58.6 ml) was irradiated with a total dose of 52.2 Gy (range, 45.0-55.8 Gy) in 1.8-Gy fractions using a linear accelerator (6 MeV photons) equipped with a micro-multileaf collimator. Maximum doses to the optic system and pituitary gland were 53.4 Gy (range, 11.5-57.6 Gy) and 53.6 Gy (range, 12.0-57.9 Gy). Results: Median follow-up was 45 months (range, 10-105 months). Local control was achieved in all but 1 patient (actuarial rate 92% at 5 years and 10 years). In 9 of 29 patients (31%), partial remission was observed (actuarial response rate 40% at 5 years and 10 years). In 4 of 26 patients (15%) with at least partial pituitary function, new hormonal deficits developed (actuarial rate 21% at 5 years and 10 years). This rate was significantly higher in patients treated for a larger PTV ( 25 ml: 0% vs. 42% at 5 years and 10 years, p = 0.028). Visual function improved in 4 of 15 patients (27%) who had prior impairment. None of the patients developed treatment-related optic neuropathy, but 2 patients experienced new disease-related visual deficits. Conclusion: Fractionated stereotactic radiotherapy for benign tumors of the perioptic and sellar region results in satisfactory response and local control rates and does not affect the visual system. The assumption that patients can be spared hypophyseal insufficiency only holds for small tumors. (orig.)

  16. Stereotactic body radiotherapy: current strategies and future development

    Science.gov (United States)

    2016-01-01

    Stereotactic body radiotherapy (SBRT) has emerged as the standard treatment for medically inoperable early-staged non-small cell lung cancer (NSCLC). The local control rate after SBRT is over 90%. Some forms of tumour motion management and image-guided radiation delivery techniques are the prerequisites for fulfilment of its goal to deliver a high radiation dose to the tumour target without overdosing surrounding normal tissues. In this review, the current strategies of tumour motion management will be discussed, followed by an overview of various image-guided radiotherapy (RT) systems and devices available for clinical practice. Besides medically inoperable stage I NSCLC, SBRT has also been widely adopted for treatment of oligometastasis involving the lungs. Its possible applications in various other cancer illnesses are under extensive exploration. The progress of SBRT is critically technology-dependent. With advancement of technology, the ideal of personalised, effective and yet safe SBRT is already on the horizon. PMID:27606082

  17. Value of stereotactic radiosurgery in patients with multiple brain metastases

    International Nuclear Information System (INIS)

    Chen Jie; Lin Zhiguo; Li Qingguo; Shen Hong

    2002-01-01

    Objective: To analyze the prognostic factors and evaluate the effect of stereotactic radiosurgery for patients with multiple brain metastases. Methods: Comparison was made in 53 such patients treated by stereotactic radiosurgery plus radiotherapy and 53 treated by radiotherapy alone. Patients were matched-paired according to the following criteria: age, Karnofsky performance scale (KPS) before treatment, extent of systemic cancer and number of brain metastasis. Forty patients had stereotactic radiosurgery, 13 patients stereotactic fractionated radiosurgery. In the stereotactic radiosurgery group, the patients were given a mean marginal dose of 20 Gy. Methods of stereotactic fractionated radiosurgery was 4-12 Gy per fraction , twice a week to a total dose of 15-30 Gy. Whole brain radiotherapy was given immediately after stereotactic radiosurgery. For patients treated by radiotherapy alone, the entire brain was treated by 30-40 Gy in 3-4 weeks. Results: The median survival was 11.6 months in stereotactic radiosurgery plus radiotherapy and 6.7 months in radiotherapy alone. The one year survival rate and one year local control rate were 44.3%, 17.1% and 50.9%, 13. 2%. Those with KPS increased after treatment gave 1-year survivals of 69.8% and 30.2%, respectively. The validity rates in CT or MRI three months after treatment were 82.0% and 55.0%. The difference in the two groups was found to be statistically significant (P < 0.01). 23.3% of death in the stereotactic radiosurgery plus radiotherapy group was due to brain metastasis vs 51.0% in the radiotherapy alone group (P < 0.05). Complication of the two groups was similar. Conclusion: Stereotactic radiosurgery plus radiotherapy is superior to radiotherapy alone for multiple brain metastases in improving the local control and ultimate outcome

  18. Robust frameless stereotactic localization in extra-cranial radiotherapy

    International Nuclear Information System (INIS)

    Riboldi, Marco; Baroni, Guido; Spadea, Maria Francesca; Bassanini, Fabio; Tagaste, Barbara; Garibaldi, Cristina; Orecchia, Roberto; Pedotti, Antonio

    2006-01-01

    In the field of extra-cranial radiotherapy, several inaccuracies can make the application of frameless stereotactic localization techniques error-prone. When optical tracking systems based on surface fiducials are used, inter- and intra-fractional uncertainties in marker three-dimensional (3D) detection may lead to inexact tumor position estimation, resulting in erroneous patient setup. This is due to the fact that external fiducials misdetection results in deformation effects that are poorly handled in a rigid-body approach. In this work, the performance of two frameless stereotactic localization algorithms for 3D tumor position reconstruction in extra-cranial radiotherapy has been specifically tested. Two strategies, unweighted versus weighted, for stereotactic tumor localization were examined by exploiting data coming from 46 patients treated for extra-cranial lesions. Measured isocenter displacements and rotations were combined to define isocentric procedures, featuring 6 degrees of freedom, for correcting patient alignment (isocentric positioning correction). The sensitivity of the algorithms to uncertainties in the 3D localization of fiducials was investigated by means of 184 numerical simulations. The performance of the implemented isocentric positioning correction was compared to conventional point-based registration. The isocentric positioning correction algorithm was tested on a clinical dataset of inter-fractional and intra-fractional setup errors, which was collected by means of an optical tracker on the same group of patients. The weighted strategy exhibited a lower sensitivity to fiducial localization errors in simulated misalignments than those of the unweighted strategy. Isocenter 3D displacements provided by the weighted strategy were consistently smaller than those featured by the unweighted strategy. The peak decrease in median and quartile values of isocenter 3D displacements were 1.4 and 2.7 mm, respectively. Concerning clinical data, the

  19. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients

    DEFF Research Database (Denmark)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben

    2017-01-01

    OBJECTIVE: Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) ... to patients treated with fractionated stereotactic radiotherapy. RESULTS: No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were...... included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45...

  20. Fractionated Stereotactic Radiotherapy in the Treatment of Vestibular Schwannoma (Acoustic Neuroma): Predicting the Risk of Hydrocephalus

    International Nuclear Information System (INIS)

    Powell, Ceri; Micallef, Caroline; Gonsalves, Adam; Wharram, Bev; Ashley, Sue; Brada, Michael

    2011-01-01

    Purpose: To determine the incidence and predictive factors for the development of hydrocephalus in patients with acoustic neuromas (AN) treated with fractionated stereotactic radiotherapy. Patients and Methods: Seventy-two patients with AN were treated with fractionated stereotactic radiotherapy between 1998 and 2007 (45-50 Gy in 25-30 fractions over 5 to 6 weeks). The pretreatment MRI scan was assessed for tumor characteristics and anatomic distortion independently of subsequent outcome and correlated with the risk of hydrocephalus. Results: At a median follow-up of 49 months (range, 1-120 months), 5-year event-free survival was 95%. Eight patients (11%) developed hydrocephalus within 19 months of radiotherapy, which was successfully treated. On univariate analysis, pretreatment factors predictive of hydrocephalus were maximum diameter (p = 0.005), proximity to midline (p = 0.009), displacement of the fourth ventricle (p = 0.02), partial effacement of the fourth ventricle (p < 0.001), contact with the medulla (p = 0.005), and more brainstem structures (p = 0.004). On multivariate analysis, after adjusting for fourth ventricular effacement, no other variables remained independently associated with hydrocephalus formation. Conclusions: Fractionated stereotactic radiotherapy results in excellent tumor control of AN, albeit with a risk of developing hydrocephalus. Patients at high risk, identified as those with larger tumors with partial effacement of the fourth ventricle before treatment, should be monitored more closely during follow-up. It would also be preferable to offer treatment to patients with progressive AN while the risk of hydrocephalus is low, before the development of marked distortion of fourth ventricle before tumor diameter significantly exceeds 2 cm.

  1. Patient-reported quality of life after stereotactic ablative radiotherapy for early-stage lung cancer

    NARCIS (Netherlands)

    Lagerwaard, F.J.; Aaronson, N.K.; Gundy, C.M.; Haasbeek, C.J.A.; Slotman, B.J.; Senan, S.

    2012-01-01

    Background: Deterioration in health-related quality of life (HRQOL) is frequently observed after surgery for stage I non-small-cell lung cancer. As stereotactic ablative radiotherapy (SABR) can result in local control percentages exceeding 90%, we studied baseline and post-treatment HRQOL in SABR

  2. Emerging technologies in stereotactic body radiotherapy.

    Science.gov (United States)

    Ma, Lijun; Wang, Lei; Tseng, Chia-Lin; Sahgal, Arjun

    2017-09-01

    Stereotactic body radiation therapy (SBRT) stems from the initial developments of intra-cranial stereotactic radiosurgery (SRS). Despite similarity in their names and clinical goals of delivering a sufficiently high tumoricidal dose, maximal sparing of the surrounding normal tissues and a short treatment course, SBRT technologies have transformed from the early days of body frame-based treatments with X-ray verification to primarily image-guided procedures with cone-beam CT or stereoscopic X-ray systems and non-rigid body immo-bilization. As a result of the incorporation of image-guidance systems and multi-leaf col-limators into mainstream linac systems, and treatment planning systems that have also evolved to allow for routine dose calculations to permit intensity modulated radiotherapy and volumetric modulated arc therapy (VMAT), SBRT has disseminated rapidly in the community to manage many disease sites that include oligometastases, spine lesions, lung, prostate, liver, renal cell, pelvic tumors, and head and neck tumors etc. In this article, we review the physical principles and paradigms that led to the widespread adoption of SBRT practice as well as technical caveats specific to individual SBRT technologies. From the perspective of treatment delivery, we categorically described (I) C-arm linac-based SBRT technologies; (II) robotically manipulated X-band CyberKnife® technology; and (III) emerging specialized systems for SBRT that include integrated MRI-linear accelerators and the imaged-guided Gamma Knife Perfexion Icon system with expanded multi-isocenter treatments of skull-based tumors, head-and-neck and cervical-spine lesions.

  3. Clinical observation on the therapeutic efficacy of CyberKnife for primary or metastatic retroperitoneal tumors

    International Nuclear Information System (INIS)

    Zhuang Hongqing; Yuan Zhiyong; Wang Ping

    2012-01-01

    Objective: To evaluate the early response rate and radiation toxicity of CyberKnife in the treatment of primary or metastatic retroperitoneal tumors. Methods: Twenty-eight patients with retroperitoneal tumors were treated with CyberKnife. The total doses were 2000-6000 cGy (median 4500 cGy) and biological effective doses were 3750-10080 cGy (median 7680 cGy) in 2-10 fractions (median 5). Of all patients, 3 received three dimensional conformal radiotherapy (3DCRT) or intensity modulated radiotherapy (IMRT) boost, 1 was treated as second-course radiotherapy, and others were treated with CyberKnife only. The survival rates were calculated by Kaplan-Meier method and compared with Logrank test. Results: The complete response, stable disease and progression disease rates were 43% (12/28), 6% (10/28), 18% (5/28), 4%, (1/28), respectively. The overall response rate was 96%. The number of patients who were followed up more than 1, 2, 3 years were 17, 9, 7, respectively. The 1-, 2- and 3-year local control rates were 92%, 86%, and 86%, respectively. The 1-, 2- and 3-year overall survival rates were 60%, 49% and 49%, respectively. The difference between local progression-free survival and overall survival was not significant (median 9.5 and 12.0 months, χ 2 =0.17, P=0.680), Moreover, if the patients did not have metastasis elsewhere and local treatment was effective, there was no significant difference between local progression-free survival and progression free survival (median 17 and 11 months, χ 2 =0.13, P=0.720), Acute radiation-induced side effects (≥ 2 grade) such as fatigue, anorexia, nausea, vomiting and epigastric discomfort occurred in 9, 9, 7, 7 and 2 patients, respectively. Intestinal stenosis of 1 grade occurred in 1 patients. Conclusions: Radiotherapy for retroperitoneal tumors with CyberKnife has provided a high response rate with minimal side effects. It is a safe and effective local treatment method for retroperitoneal tumors. (authors)

  4. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    International Nuclear Information System (INIS)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok

    2013-01-01

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  5. A New Cancer Radiotherapy System Using Multi Robotic Manipulators

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Seung Ho; Lee, Nam Ho; Lee, Byung Chul; Jeung, Kyung Min; Lee, Seong Uk; Bae, Yeong Geol; Na, Hyun Seok [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2013-10-15

    The CyberKnife system is state-of-the-art cancer treatment equipment that combines an image tracking technique, artificial intelligence software, robot technology, accelerator technology, and treatment simulation technology. The current CyberKnife System has significant shortcomings. The biggest problem is that it takes a longer time to treat a tumor. A long treatment time gives stress to patients. Furthermore it makes the patients uncomfortable with radiation and thus it is difficult to measure the exact radiation dose rate to the tumor in the processing. Linear accelerators for radiation treatment are dependent on imports, and demand high maintenance cost. This also makes the treatment cost higher and prevents the popularization of radiation. To solve the disadvantages of the existing CyberKnife, a radiation treatment robot system applied to several articulated robots is suggested. Essential element techniques for new radiotherapy robot system are investigated and some problems of similar existing systems are analyzed. This paper presents a general configuration of a new radiation robot treatment system including with a quantitative goal of the requirement techniques. This paper described a new radiotherapy robot system to track the tumor using multiple articulated robots in real time. The existing CyberKnife system using a single robot arm has disadvantages of a long radiotherapy time, high medical fee, and inaccurate measurement of the radiotherapy dose. So a new radiotherapy robot system for tumors has been proposed to solve the above problems of conventional CyberKnife systems. Necessary technologies to configure new the radiotherapy robot system have been identified. Quantitative targets of each technology have been established. Multiple robot arms are adopted to decrease the radiotherapy time. The results of this research are provided as a requisite technology for a domestic radiotherapy system and are expected to be the foundation of new technology. The

  6. Definition of stereotactic body radiotherapy. Principles and practice for the treatment of stage I non-small cell lung cancer

    International Nuclear Information System (INIS)

    Guckenberger, M.; Sauer, O.; Andratschke, N.; Alheit, H.; Holy, R.; Moustakis, C.; Nestle, U.

    2014-01-01

    This report from the Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (Deutschen Gesellschaft fuer Radioonkologie, DEGRO) provides a definition of stereotactic body radiotherapy (SBRT) that agrees with that of other international societies. SBRT is defined as a method of external beam radiotherapy (EBRT) that accurately delivers a high irradiation dose to an extracranial target in one or few treatment fractions. Detailed recommendations concerning the principles and practice of SBRT for early stage non-small cell lung cancer (NSCLC) are given. These cover the entire treatment process; from patient selection, staging, treatment planning and delivery to follow-up. SBRT was identified as the method of choice when compared to best supportive care (BSC), conventionally fractionated radiotherapy and radiofrequency ablation. Based on current evidence, SBRT appears to be on a par with sublobar resection and is an effective treatment option in operable patients who refuse lobectomy. (orig.) [de

  7. Stereotactic radiosurgery versus stereotactic radiotherapy for patients with vestibular schwannoma: a Leksell Gamma Knife Society 2000 debate.

    Science.gov (United States)

    Linskey, Mark E

    2013-12-01

    By definition, the term "radiosurgery" refers to the delivery of a therapeutic radiation dose in a single fraction, not simply the use of stereotaxy. Multiple-fraction delivery is better termed "stereotactic radiotherapy." There are compelling radiobiological principles supporting the biological superiority of single-fraction radiation for achieving an optimal therapeutic response for the slowly proliferating, late-responding, tissue of a schwannoma. It is axiomatic that complication avoidance requires precise three-dimensional conformality between treatment and tumor volumes. This degree of conformality can only be achieved through complex multiisocenter planning. Alternative radiosurgery devices are generally limited to delivering one to four isocenters in a single treatment session. Although they can reproduce dose plans similar in conformality to early gamma knife dose plans by using a similar number of isocenters, they cannot reproduce the conformality of modern gamma knife plans based on magnetic resonance image--targeted localization and five to 30 isocenters. A disturbing trend is developing in which institutions without nongamma knife radiosurgery (GKS) centers are championing and/or shifting to hypofractionated stereotactic radiotherapy for vestibular schwannomas. This trend appears to be driven by a desire to reduce complication rates to compete with modern GKS results by using complex multiisocenter planning. Aggressive advertising and marketing from some of these centers even paradoxically suggests biological superiority of hypofractionation approaches over single-dose radiosurgery for vestibular schwannomas. At the same time these centers continue to use the term radiosurgery to describe their hypofractionated radiotherapy approach in an apparent effort to benefit from a GKS "halo effect." It must be reemphasized that as neurosurgeons our primary duty is to achieve permanent tumor control for our patients and not to eliminate complications at the

  8. Geometric accuracy of field alignment in fractionated stereotactic conformal radiotherapy of brain tumors

    International Nuclear Information System (INIS)

    Kortmann, Rolf D.; Becker, Gerd; Perelmouter, Jury; Buchgeister, Markus; Meisner, Christoph; Bamberg, Michael

    1999-01-01

    Purpose: To assess the accuracy of field alignment in patients undergoing three-dimensional (3D) conformal radiotherapy of brain tumors, and to evaluate the impact on the definition of planning target volume and control procedures. Methods and Materials: Geometric accuracy was analyzed in 20 patients undergoing fractionated stereotactic conformal radiotherapy for brain tumors. Rigid head fixation was achieved by using cast material. Transfer of stereotactic coordinates was performed by an external positioning device. The accuracy during treatment planning was quantitatively assessed by using repeated computed tomography (CT) examinations in treatment position (reproducibility of isocenter). Linear discrepancies were measured between treatment plan and CT examination. In addition, for each patient, a series of 20 verifications were taken in orthogonal projections. Linear discrepancies were measured between first and all subsequent verifications (accuracy during treatment delivery). Results: For the total group of patients, the distribution of deviations during treatment setup showed mean values between -0.3-1.2 mm, with standard deviations (SD) of 1.3-2.0 mm. During treatment delivery, the distribution of deviations revealed mean values between 0.7-0.8 mm, with SDs of 0.5-0.6 mm, respectively. For all patients, deviations for the transition to the treatment machine were similar to deviations during subsequent treatment delivery, with 95% of all absolute deviations between less than 2.8 and 4.6 mm. Conclusion: Random fluctuations of field displacements during treatment planning and delivery prevail. Therefore, our quantitative data should be considered when prescribing the safety margins of the planning target volume. Repeated CT examination are useful to detect operator errors and large random or systematic deviations before start of treatment. Control procedures during treatment delivery appear to be of limited importance. In addition, our findings should help to

  9. The safety and efficacy of robotic image-guided radiosurgery system treatment for intra- and extracranial lesions: A systematic review of the literature

    International Nuclear Information System (INIS)

    Calcerrada Diaz-Santos, Nieves; Blasco Amaro, Juan Antonio; Cardiel, Gloria Ariza; Andradas Aragones, Elena

    2008-01-01

    Background: The CyberKnife is a new, frameless stereotactic radiosurgery system. This work reviews its safety and efficacy in the treatment of intra- and extracranial lesions. Methods: A literature search was made of the Medline, Embase, Pascal Biomed, CINAHL and Cancerlit databases. Health technology assessment reports on stereotactic radiosurgery systems were also consulted. All searches were made in June 2007. Data on efficacy and safety were extracted and then synthesized into the present review. Results: Thirty five clinical studies were identified, the majority of which included no patient comparison group. These studies assessed the use of the CyberKnife mainly in the treatment of primary and metastatic intracranial and spinal tumours. Conclusions: The CyberKnife system allows to carry out standard radiosurgical and fractionated stereotactic radiotherapy procedures. The use of this system offers an alternative for the treatment of inoperable tumours, and of lesions located close to critical structures that cannot be treated using other types of stereotactic radiosurgery system. Unfortunately, the quality of the reviewed papers still does not allow definite conclusions to be drawn regarding the safety and efficacy of these treatments

  10. Fiducial-free CyberKnife stereotactic body radiation therapy (SBRT) for single vertebral body metastases: acceptable local control and normal tissue tolerance with 5 fraction approach

    Energy Technology Data Exchange (ETDEWEB)

    Gill, Beant; Oermann, Eric; Ju, Andrew; Suy, Simeng; Yu, Xia; Rabin, Jennifer [Department of Radiation Medicine, Georgetown University Hospital,, Washington, DC (United States); Kalhorn, Christopher; Nair, Mani N.; Voyadzis, Jean-Marc [Department of Neurosurgery, Georgetown University Hospital,, Washington, DC (United States); Unger, Keith; Collins, Sean P.; Harter, K. W.; Collins, Brian T., E-mail: collinsb@gunet.georgetown.edu [Department of Radiation Medicine, Georgetown University Hospital,, Washington, DC (United States)

    2012-04-26

    This retrospective analysis examines the local control and toxicity of five-fraction fiducial-free CyberKnife stereotactic body radiation therapy (SBRT) for single vertebral body (VB) metastases. All patients had favorable performance status (ECOG 0–1), oligometastatic disease, and no prior spine irradiation. A prescribed dose of 30–35 Gy was delivered in five fractions to the planning target volume (PTV) using the CyberKnife with X-sight spine tracking. Suggested maximum spinal cord and esophagus point doses were 30 and 40 Gy, respectively. A median 30 Gy (IQR, 30–35 Gy) dose was delivered to a median prescription isodose line of 70% (IQR, 65–77%) to 20 patients. At 34 months median follow-up (IQR, 25–40 months) for surviving patients, the 1- and 2-year Kaplan–Meier local control estimates were 80 and 73%, respectively. Two of the five local failures were infield in patients who had received irradiation to the gross tumor volume and three were paravertebral failures just outside the PTV in patients with prior corpectomy. No local failures occurred in patients who completed VB radiation alone. The 1- and 2-year Kaplan–Meier overall survival estimates were 80 and 57%, respectively. Most deaths were attributed to metastatic disease; one death was attributed to local recurrence. The mean maximum point doses were 26.4 Gy (SD, 5.1 Gy) to the spinal cord and 29.1 Gy (SD, 8.9 Gy) to the esophagus. Patients receiving maximum esophagus point doses greater than 35 Gy experienced acute dysphagia (Grade I/II). No spinal cord toxicity was documented. Five-fraction fiducial-free CyberKnife SBRT is an acceptable treatment option for newly diagnosed VB metastases with promising local control rates and minimal toxicity despite the close proximity of such tumors to the spinal cord and esophagus. A prospective study aimed at further enhancing local control by targeting the intact VB and escalating the total dose is planned.

  11. Quality of Life After Stereotactic Radiotherapy for Stage I Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Voort van Zyp, Noelle C. van der; Prevost, Jean-Briac; Holt, Bronno van der; Braat, Cora; Klaveren, Robertus J. van; Pattynama, Peter M.; Levendag, Peter C.; Nuyttens, Joost J.

    2010-01-01

    Purpose: To determine the impact of stereotactic radiotherapy on the quality of life of patients with inoperable early-stage non-small-cell lung cancer (NSCLC). Overall survival, local tumor control, and toxicity were also evaluated in this prospective study. Methods and Materials: From January 2006 to February 2008, quality of life, overall survival, and local tumor control were assessed in 39 patients with pathologically confirmed T1 to 2N0M0 NSCLC. These patients were treated with stereotactic radiotherapy. The European Organization for Research and Treatment of Cancer Quality of Life Questionnaire (EORTC QLQ) C30 and the QLQ LC13 lung cancer-specific questionnaire were used to investigate changes in quality of life. Assessments were done before treatment, at 3 weeks, and at 2, 4, 6, 9, and 12 months after treatment, until death or progressive disease. Toxicity was evaluated using common terminology criteria for adverse events version 3.0. Results: Emotional functioning improved significantly after treatment. Other function scores and QLQ C30 and QLQ LC13 lung symptoms (such as dyspnea and coughing) showed no significant changes. The overall 2-year survival rate was 62%. After a median follow-up of 17 months, 1 patient had a local recurrence (3%). No grade 4 or 5 treatment-related toxicity occurred. Grade 3 toxicity consisted of thoracic pain, which occurred in 1 patient within 4 months of treatment, while it occurred thereafter in 2 patients. Conclusions: Quality of life was maintained, and emotional functioning improved significantly after stereotactic radiotherapy for stage I NSCLC, while survival was acceptable, local tumor control was high, and toxicity was low.

  12. Stereotactic body radiotherapy for lung cancer: how much does it really cost?

    Science.gov (United States)

    Lievens, Yolande; Obyn, Caroline; Mertens, Anne-Sophie; Van Halewyck, Dries; Hulstaert, Frank

    2015-03-01

    Despite the lack of randomized evidence, stereotactic body radiotherapy (SBRT) is being accepted as superior to conventional radiotherapy for patients with T1-2N0 non-small-cell lung cancer in the periphery of the lung and unfit or unwilling to undergo surgery. To introduce SBRT in a system of coverage with evidence development, a correct financing had to be determined. A time-driven activity-based costing model for radiotherapy was developed. Resource cost calculation of all radiotherapy treatments, standard and innovative, was conducted in 10 Belgian radiotherapy centers in the second half of 2012. The average cost of lung SBRT across the 10 centers (6221&OV0556;) is in the range of the average costs of standard fractionated 3D-conformal radiotherapy (5919&OV0556;) and intensity-modulated radiotherapy (7379&OV0556;) for lung cancer. Hypofractionated 3D-conformal radiotherapy and intensity-modulated radiotherapy schemes are less costly (3993&OV0556; respectively 4730&OV0556;). The SBRT cost increases with the number of fractions and is highly dependent of personnel and equipment use. SBRT cost varies more by centre than conventional radiotherapy cost, reflecting different technologies, stages in the learning curve and a lack of clear guidance in this field. Time-driven activity-based costing of radiotherapy is feasible in a multicentre setup, resulting in real-life resource costs that can form the basis for correct reimbursement schemes, supporting an early yet controlled introduction of innovative radiotherapy techniques in clinical practice.

  13. Measurement of the absorbed dose in the very small size photon beams used in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Derreumaux, S.; Huet, C.; Robbes, I.; Trompier, F.; Boisserie, G.; Brunet, G.; Buchheit, I.; Sarrazin, T.; Chea, M.

    2008-01-01

    After the radiotherapy accident in Toulouse, the French authority of nuclear safety and the French agency of health products safety have asked the IR.S.N. to establish, together with experts from the French society of medical physics and the French society of radiotherapy and oncology, a national protocol on dose calibration for the very small beams used in stereotactic radiotherapy. The research and reflexions of the working group 'GT minifaisceaux ' set up by the I.R.S.N. are presented in this final report. A review of the international literature has been performed. A national survey has been done to know the present practices in the dosimetry of small fields. A campaign of measurements of the data needed to characterize the small beams for the different stereotactic systems has started, using different types of detectors acquired by the I.R.S.N.. In this report are presented a deep synthesis on the problems related to the dosimetry of small fields, the results of the national survey, the first results of the campaign of measurements and the recommendations of the GT. (authors)

  14. Management of acoustic neuromas with fractionated stereotactic radiotherapy (FSRT): Long-term results in 106 patients treated in a single institution

    International Nuclear Information System (INIS)

    Combs, Stephanie E.; Volk, Sigrid; Schulz-Ertner, Daniela; Huber, Peter E.; Thilmann, Christoph; Debus, Juergen

    2005-01-01

    Purpose: To assess the long-term outcome and toxicity of fractionated stereotactic radiotherapy for acoustic neuromas in 106 patients treated in a single institution. Patients and Methods: Between October 1989 and January 2004, fractionated stereotactic radiotherapy (FSRT) was performed in 106 patients with acoustic neuroma (AN). The median total dose applied was 57.6 Gy in median single fractions of 1.8 Gy in five fractions per week. The median irradiated tumor volume was 3.9 mL (range, 2.7-30.7 mL). The median follow-up time was 48.5 months (range, 3-172 months). Results: Fractionated stereotactic radiotherapy was well tolerated in all patients. Actuarial local tumor control rates at 3- and 5- years after FSRT were 94.3% and 93%, respectively. Actuarial useful hearing preservation was 94% at 5 years. The presence of neurofibromatosis (NF-2) significantly adversely influenced hearing preservation in patients that presented with useful hearing at the initiation of RT (p = 0.00062). Actuarial hearing preservation without the diagnosis of NF-2 was 98%. In cases with NF-2, the hearing preservation rate was 64%. Cranial nerve toxicity other than hearing impairment was rare. The rate of radiation induced toxicity to the trigeminal and facial nerve was 3.4% and 2.3%, respectively. Conclusion: Fractionated stereotactic radiotherapy is safe and efficacious for the treatment of AN, with mild toxicity with regard to hearing loss and cranial nerve function. FSRT might be considered as an equieffective treatment modality compared to neurosurgery and therefore represents an interesting alternative therapy for patients with AN

  15. Target migration from re-inflation of adjacent atelectasis during lung stereotactic body radiotherapy.

    Science.gov (United States)

    Mao, Bijing; Verma, Vivek; Zheng, Dandan; Zhu, Xiaofeng; Bennion, Nathan R; Bhirud, Abhijeet R; Poole, Maria A; Zhen, Weining

    2017-06-10

    Stereotactic body radiotherapy (SBRT) is a widely accepted option for the treatment of medically inoperable early-stage non-small cell lung cancer (NSCLC). Herein, we highlight the importance of interfraction image guidance during SBRT. We describe a case of early-stage NSCLC associated with segmental atelectasis that translocated 15 mm anteroinferiorly due to re-expansion of the adjacent segmental atelectasis following the first fraction. The case exemplifies the importance of cross-sectional image-guided radiotherapy that shows the intended target, as opposed to aligning based on rigid anatomy alone, especially in cases associated with potentially "volatile" anatomic areas.

  16. Radiogenic Side Effects After Hypofractionated Stereotactic Photon Radiotherapy of Choroidal Melanoma in 212 Patients Treated Between 1997 and 2007

    Energy Technology Data Exchange (ETDEWEB)

    Dunavoelgyi, Roman [Department of Ophthalmology, Medical University of Vienna, Vienna (Austria); Dieckmann, Karin [Department of Radiology, Medical University of Vienna, Vienna (Austria); Gleiss, Andreas [Section of Clinical Biometrics, Medical University of Vienna, Vienna (Austria); Sacu, Stefan; Kircher, Karl; Georgopoulos, Michael [Department of Ophthalmology, Medical University of Vienna, Vienna (Austria); Georg, Dietmar [Department of Radiology, Medical University of Vienna, Vienna (Austria); Zehetmayer, Martin [Department of Ophthalmology, Medical University of Vienna, Vienna (Austria); Poetter, Richard [Department of Radiology, Medical University of Vienna, Vienna (Austria)

    2012-05-01

    Purpose: To evaluate side effects of hypofractionated stereotactic photon radiotherapy for patients with choroidal melanoma. Patients and Methods: Two hundred and twelve patients with choroidal melanoma unsuitable for ruthenium-106 brachytherapy or local resection were treated stereotactically at the Medical University of Vienna between 1997 and 2007 with a Linac with 6-MV photon beams in five fractions with 10, 12, or 14 Gy per fraction. Examinations for radiogenic side effects were performed at baseline and every 3 months in the first 2 years, then every 6 months until 5 years and then once a year thereafter until 10 years after radiotherapy. Adverse side effects were assessed using slit-lamp examination, funduscopy, gonioscopy, tonometry, and, if necessary, fundus photography and fluorescein angiography. Evaluations of incidence of side effects are based on an actuarial analysis. Results: One hundred and eighty-nine (89.2%) and 168 (79.2%) of the tumors were within 3 mm of the macula and the optic disc, respectively. The five most common radiotherapy side effects were retinopathy and optic neuropathy (114 cases and 107 cases, respectively), cataract development (87 cases), neovascular glaucoma (46 cases), and corneal epithelium defects (41 cases). In total, 33.6%, 38.5%, 51.2%, 75.5%, and 77.6% of the patients were free of any radiation retinopathy, optic neuropathy, cataract, neovascular glaucoma, or corneal epithelium defects 5 years after radiotherapy, respectively. Conclusion: In centrally located choroidal melanoma hypofractionated stereotactic photon radiotherapy shows a low to moderate rate of adverse long-term side effects comparable with those after proton beam radiotherapy. Future fractionation schemes should seek to further reduce adverse side effects rate while maintaining excellent local tumor control.

  17. Radiogenic Side Effects After Hypofractionated Stereotactic Photon Radiotherapy of Choroidal Melanoma in 212 Patients Treated Between 1997 and 2007

    International Nuclear Information System (INIS)

    Dunavoelgyi, Roman; Dieckmann, Karin; Gleiss, Andreas; Sacu, Stefan; Kircher, Karl; Georgopoulos, Michael; Georg, Dietmar; Zehetmayer, Martin; Poetter, Richard

    2012-01-01

    Purpose: To evaluate side effects of hypofractionated stereotactic photon radiotherapy for patients with choroidal melanoma. Patients and Methods: Two hundred and twelve patients with choroidal melanoma unsuitable for ruthenium-106 brachytherapy or local resection were treated stereotactically at the Medical University of Vienna between 1997 and 2007 with a Linac with 6-MV photon beams in five fractions with 10, 12, or 14 Gy per fraction. Examinations for radiogenic side effects were performed at baseline and every 3 months in the first 2 years, then every 6 months until 5 years and then once a year thereafter until 10 years after radiotherapy. Adverse side effects were assessed using slit-lamp examination, funduscopy, gonioscopy, tonometry, and, if necessary, fundus photography and fluorescein angiography. Evaluations of incidence of side effects are based on an actuarial analysis. Results: One hundred and eighty-nine (89.2%) and 168 (79.2%) of the tumors were within 3 mm of the macula and the optic disc, respectively. The five most common radiotherapy side effects were retinopathy and optic neuropathy (114 cases and 107 cases, respectively), cataract development (87 cases), neovascular glaucoma (46 cases), and corneal epithelium defects (41 cases). In total, 33.6%, 38.5%, 51.2%, 75.5%, and 77.6% of the patients were free of any radiation retinopathy, optic neuropathy, cataract, neovascular glaucoma, or corneal epithelium defects 5 years after radiotherapy, respectively. Conclusion: In centrally located choroidal melanoma hypofractionated stereotactic photon radiotherapy shows a low to moderate rate of adverse long-term side effects comparable with those after proton beam radiotherapy. Future fractionation schemes should seek to further reduce adverse side effects rate while maintaining excellent local tumor control.

  18. EORTC 22972-26991/MRC BR10 trial: Fractionated stereotactic boost following conventional radiotherapy of high grade gliomas

    International Nuclear Information System (INIS)

    Baumert, Brigitta G.; Brada, Michael; Bernier, Jacques; Kortmann, Rolf D.; Dehing-Oberije, Cary; Collette, Laurence; Davis, J. Bernard

    2008-01-01

    Background and purpose: The EORTC trial No. 22972 investigated the role of an additional fractionated stereotactic boost (fSRT) to conventional radiotherapy for patients with high grade gliomas. A quality-assurance (QA) programme was run in conjunction with the study and was the first within the EORTC addressing the quality of a supposedly highly accurate treatment technique such as stereotactic radiotherapy. A second aim was to investigate a possible relation between the clinical results of the stereotactic boost arm and the results of the QA. Materials and methods: The trial was closed in 2001 due to low accrual. In total, 25 patients were randomized: 14 into the experimental arm and 11 into the control arm. Six centres randomized patients, 8 centres had completed the dummy run (DR) for the stereotactic boost part. All participating centres (9) were asked to complete a quality-assurance questionnaire. The DR consisted of treatment planning according to the guidelines of the protocol on 3 different tumour volumes drawn on CT images of a humanized phantom. The SRT technique to be used was evaluated by the questionnaire. Clinical data from patients recruited to the boost arm from 6 participating centres were analysed. Results: There was a full compliance to the protocol requirements for 5 centres. Major and minor deviations in conformality were observed for 2 and 3 centres, respectively. Of the 8 centres which completed the DR, one centre did not comply with the requirements of stereotactic radiotherapy concerning accuracy, dosimetry and planning. Median follow-up and median overall survival were 39.2 and 21.4 months, respectively. Acute and late toxicities of the stereotactic boost were low. One radiation necrosis was seen for a patient who has not received the SRT boost. Three reported serious adverse events were all seizures and probably therapy-related. Conclusions: Overall compliance was good but not ideal from the point of view of this highly precise radiation

  19. Treatment and technical intervention time analysis of a robotic stereotactic radiotherapy system.

    Science.gov (United States)

    Crop, F; Lacornerie, T; Szymczak, H; Felin, A; Bailleux, C; Mirabel, X; Lartigau, E

    2014-02-01

    The purpose of this study is to obtain a better operational knowledge of Stereotactic Body Radiotherapy (SBRT) treatments with CyberKnife(r). An analysis of both In-room Times (IRT) and technical interventions of 5 years of treatments was performed, during which more than 1600 patients were treated for various indications, including liver (21%), lung (29%), intracranial (13%), head and neck (11%) and prostate (7%). Technical interventions were recorded along with the time of the failure, time to the intervention, and the complexity and duration of the repair. Analyses of Time Between Failures (TBF) and Service Disrupting TBF(disr) were performed. Treatment time data and variability per indication and following different system upgrades were evaluated. Large variations of IRTs were found between indications, but also large variations for each indication. The combination of the time reduction Tool (using Iris(r)) and Improved Stop Handling was of major impact to shortening of treatment times. The first implementation of the Iris collimator alone did not lead to significantly shorter IRTs for us except during prostate treatments. This was mostly due to the addition at the same time of larger rotational compensation for prostate treatments (58 instead of 1.58). Significant differences of duration between the first fraction and following fractions of a treatment, representing the necessity of defining imaging parameters and explanation to patients, were found for liver (12 min) and lung treatments using Xsight(r) Spine (5 min). Liver and lung treatments represent the longest IRT's and involve the largest variability's in IRT. The malfunction rate of the system followed a Weibull distribution with the shape and scale parameters of 0.8 and 39.7. Mean TBF(disr) was 68 work hours. 60 to 80% of the service disrupting interventions were resolved within 30-60 min, 5% required external intervention and 30% occurred in the morning. The presented results can be applied in the

  20. Recommendations for implementing stereotactic radiotherapy in peripheral stage IA non-small cell lung cancer: report from the Quality Assurance Working Party of the randomised phase III ROSEL study

    International Nuclear Information System (INIS)

    Hurkmans, Coen W; Cuijpers, Johan P; Lagerwaard, Frank J; Widder, Joachim; Heide, Uulke A van der; Schuring, Danny; Senan, Suresh

    2009-01-01

    A phase III multi-centre randomised trial (ROSEL) has been initiated to establish the role of stereotactic radiotherapy in patients with operable stage IA lung cancer. Due to rapid changes in radiotherapy technology and evolving techniques for image-guided delivery, guidelines had to be developed in order to ensure uniformity in implementation of stereotactic radiotherapy in this multi-centre study. A Quality Assurance Working Party was formed by radiation oncologists and clinical physicists from both academic as well as non-academic hospitals that had already implemented stereotactic radiotherapy for lung cancer. A literature survey was conducted and consensus meetings were held in which both the knowledge from the literature and clinical experience were pooled. In addition, a planning study was performed in 26 stage I patients, of which 22 were stage 1A, in order to develop and evaluate the planning guidelines. Plans were optimised according to parameters adopted from RTOG trials using both an algorithm with a simple homogeneity correction (Type A) and a more advanced algorithm (Type B). Dose conformity requirements were then formulated based on these results. Based on current literature and expert experience, guidelines were formulated for this phase III study of stereotactic radiotherapy versus surgery. These guidelines can serve to facilitate the design of future multi-centre clinical trials of stereotactic radiotherapy in other patient groups and aid a more uniform implementation of this technique outside clinical trials

  1. The integral biologically effective dose to predict brain stem toxicity of hypofractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Clark, Brenda G.; Souhami, Luis; Pla, Conrado; Al-Amro, Abdullah S.; Bahary, Jean-Paul; Villemure, Jean-Guy; Caron, Jean-Louis; Olivier, Andre; Podgorsak, Ervin B.

    1998-01-01

    Purpose: The aim of this work was to develop a parameter for use during fractionated stereotactic radiotherapy treatment planning to aid in the determination of the appropriate treatment volume and fractionation regimen that will minimize risk of late damage to normal tissue. Materials and Methods: We have used the linear quadratic model to assess the biologically effective dose at the periphery of stereotactic radiotherapy treatment volumes that impinge on the brain stem. This paper reports a retrospective study of 77 patients with malignant and benign intracranial lesions, treated between 1987 and 1995, with the dynamic rotation technique in 6 fractions over a period of 2 weeks, to a total dose of 42 Gy prescribed at the 90% isodose surface. From differential dose-volume histograms, we evaluated biologically effective dose-volume histograms and obtained an integral biologically-effective dose (IBED) in each case. Results: Of the 77 patients in the study, 36 had target volumes positioned so that the brain stem received more than 1% of the prescribed dose, and 4 of these, all treated for meningioma, developed serious late damage involving the brain stem. Other than type of lesion, the only significant variable was the volume of brain stem exposed. An analysis of the IBEDs received by these 36 patients shows evidence of a threshold value for late damage to the brain stem consistent with similar thresholds that have been determined for external beam radiotherapy. Conclusions: We have introduced a new parameter, the IBED, that may be used to represent the fractional effective dose to structures such as the brain stem that are partially irradiated with stereotactic dose distributions. The IBED is easily calculated prior to treatment and may be used to determine appropriate treatment volumes and fractionation regimens minimizing possible toxicity to normal tissue

  2. Re-irradiation of recurrent anaplastic ependymoma using radiosurgery or fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Murai, Taro; Sato, Kengo; Iwabuchi, Michio; Manabe, Yoshihiko; Ogino, Hiroyuki; Iwata, Hiromitsu; Tatewaki, Koshi; Yokota, Naoki; Ohta, Seiji; Shibamoto, Yuta

    2016-03-01

    Recurrent ependymomas were retreated with stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT). The efficacy, toxicities, and differences between SRS and FSRT were analyzed. Eight patients with recurrent ependymomas fulfilling the criteria described below were evaluated. Inclusion criteria were: (1) the patient had previously undergone surgery and conventional radiotherapy as first-line treatment; (2) targets were located in or adjacent to the eloquent area or were deep-seated; and (3) the previously irradiated volume overlapped the target lesion. FSRT was delivered to 18 lesions, SRS to 20 lesions. A median follow-up period was 23 months. The local control rate was 76 % at 3 years. No significant differences in local control were observed due to tumor size or fractionation schedule. Lesions receiving >25 Gy/5 fr or 21 Gy/3 fr did not recur within 1 year, whereas no dose-response relationship was observed in those treated with SRS. No grade ≥2 toxicity was observed. Our treatment protocol provided an acceptable LC rate and minimal toxicities. Because local recurrence of tumors may result in patient death, a minimum dose of 21 Gy/3 fr or 25 Gy/5 fr or higher may be most suitable for treatment of these cases.

  3. Respiratory gating during stereotactic body radiotherapy for lung cancer reduces tumor position variability.

    Science.gov (United States)

    Saito, Tetsuo; Matsuyama, Tomohiko; Toya, Ryo; Fukugawa, Yoshiyuki; Toyofuku, Takamasa; Semba, Akiko; Oya, Natsuo

    2014-01-01

    We evaluated the effects of respiratory gating on treatment accuracy in lung cancer patients undergoing lung stereotactic body radiotherapy by using electronic portal imaging device (EPID) images. Our study population consisted of 30 lung cancer patients treated with stereotactic body radiotherapy (48 Gy/4 fractions/4 to 9 days). Of these, 14 were treated with- (group A) and 16 without gating (group B); typically the patients whose tumors showed three-dimensional respiratory motion ≧5 mm were selected for gating. Tumor respiratory motion was estimated using four-dimensional computed tomography images acquired during treatment simulation. Tumor position variability during all treatment sessions was assessed by measuring the standard deviation (SD) and range of tumor displacement on EPID images. The two groups were compared for tumor respiratory motion and position variability using the Mann-Whitney U test. The median three-dimensional tumor motion during simulation was greater in group A than group B (9 mm, range 3-30 mm vs. 2 mm, range 0-4 mm; psimulation, tumor position variability in the EPID images was low and comparable to patients treated without gating. This demonstrates the benefit of respiratory gating.

  4. Fractionated stereotactic radiotherapy for skull base tumors: analysis of treatment accuracy using a stereotactic mask fixation system

    Directory of Open Access Journals (Sweden)

    Montagnoli Roberto

    2010-01-01

    Full Text Available Abstract Background To assess the accuracy of fractionated stereotactic radiotherapy (FSRT using a stereotactic mask fixation system. Patients and Methods Sixteen patients treated with FSRT were involved in the study. A commercial stereotactic mask fixation system (BrainLAB AG was used for patient immobilization. Serial CT scans obtained before and during FSRT were used to assess the accuracy of patient immobilization by comparing the isocenter position. Daily portal imaging were acquired to establish day to day patient position variation. Displacement errors along the different directions were calculated as combination of systematic and random errors. Results The mean isocenter displacements based on localization and verification CT imaging were 0.1 mm (SD 0.3 mm in the lateral direction, 0.1 mm (SD 0.4 mm in the anteroposterior, and 0.3 mm (SD 0.4 mm in craniocaudal direction. The mean 3D displacement was 0.5 mm (SD 0.4 mm, being maximum 1.4 mm. No significant differences were found during the treatment (P = 0.4. The overall isocenter displacement as calculated by 456 anterior and lateral portal images were 0.3 mm (SD 0.9 mm in the mediolateral direction, -0.2 mm (SD 1 mm in the anteroposterior direction, and 0.2 mm (SD 1.1 mm in the craniocaudal direction. The largest displacement of 2.7 mm was seen in the cranio-caudal direction, with 95% of displacements Conclusions The results indicate that the setup error of the presented mask system evaluated by CT verification scans and portal imaging are minimal. Reproducibility of the isocenter position is in the best range of positioning reproducibility reported for other stereotactic systems.

  5. Stereotactic Fractionated Radiotherapy in the Treatment of Juxtapapillary Choroidal Melanoma: The McGill University Experience

    Energy Technology Data Exchange (ETDEWEB)

    Al-Wassia, Rolina; Dal Pra, Alan; Shun, Kitty; Shaban, Ahmed [Department of Oncology, Division of Radiation Oncology, Montreal General Hospital, McGill University Health Centre, Montreal, Quebec (Canada); Corriveau, Christine [Department of Ophthalmology, Notre Dame Hospital, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Edelstein, Chaim; Deschenes, Jean [Department of Ophthalmology, McGill University Health Centre, Montreal, Quebec (Canada); Ruo, Russel; Patrocinio, Horacio [Department of Medical Physics, Montreal General Hospital, McGill University Health Centre, Montreal, Quebec (Canada); Cury, Fabio L.B. [Department of Oncology, Division of Radiation Oncology, Montreal General Hospital, McGill University Health Centre, Montreal, Quebec (Canada); DeBlois, Francois [Department of Medical Physics, Jewish General Hospital, McGill University, Montreal, Quebec (Canada); Shenouda, George, E-mail: george.shenouda@muhc.mcgill.ca [Department of Oncology, Division of Radiation Oncology, Montreal General Hospital, McGill University Health Centre, Montreal, Quebec (Canada)

    2011-11-15

    Purpose: To report our experience with linear accelerator-based stereotactic fractionated radiotherapy in the treatment of juxtapapillary choroidal melanoma. Methods and Materials: We performed a retrospective review of 50 consecutive patients diagnosed with juxtapapillary choroidal melanoma and treated with linear accelerator-based stereotactic fractionated radiotherapy between April 2003 and December 2009. Patients with small to medium sized lesions (Collaborative Ocular Melanoma Study classification) located within 2 mm of the optic disc were included. The prescribed radiation dose was 60 Gy in 10 fractions. The primary endpoints included local control, enucleation-free survival, and complication rates. Results: The median follow-up was 29 months (range, 1-77 months). There were 31 males and 29 females, with a median age of 69 years (range, 30-92 years). Eighty-four percent of the patients had medium sized lesions, and 16% of patients had small sized lesions. There were four cases of local progression (8%) and three enucleations (6%). Actuarial local control rates at 2 and 5 years were 93% and 86%, respectively. Actuarial enucleation-free survival rates at 2 and 5 years were 94% and 84%, respectively. Actuarial complication rates at 2 and 5 years were 33% and 88%, respectively, for radiation-induced retinopathy; 9.3% and 46.9%, respectively, for dry eye; 12% and 53%, respectively, for cataract; 30% and 90%, respectively, for visual loss [Snellen acuity (decimal equivalent), <0.1]; 11% and 54%, respectively, for optic neuropathy; and 18% and 38%, respectively, for neovascular glaucoma. Conclusions: Linear accelerator-based stereotactic fractionated radiotherapy using 60 Gy in 10 fractions is safe and has an acceptable toxicity profile. It has been shown to be an effective noninvasive treatment for juxtapapillary choroidal melanomas.

  6. Dose delivery verification and accuracy assessment of stereotaxy in stereotactic radiotherapy and radiosurgery

    International Nuclear Information System (INIS)

    Pelagade, S.M.; Bopche, T.T.; Namitha, K.; Munshi, M.; Bhola, S.; Sharma, H.; Patel, B.K.; Vyas, R.K.

    2008-01-01

    The outcome of stereotactic radiotherapy (SRT) and stereotactic radiosurgery (SRS) in both benign and malignant tumors within the cranial region highly depends on precision in dosimetry, dose delivery and the accuracy assessment of stereotaxy associated with the unit. The frames BRW (Brown-Roberts-Wells) and GTC (Gill- Thomas-Cosman) can facilitate accurate patient positioning as well as precise targeting of tumours. The implementation of this technique may result in a significant benefit as compared to conventional therapy. As the target localization accuracy is improved, the demand for treatment planning accuracy of a TPS is also increased. The accuracy of stereotactic X Knife treatment planning system has two components to verify: (i) the dose delivery verification and the accuracy assessment of stereotaxy; (ii) to ensure that the Cartesian coordinate system associated is well established within the TPS for accurate determination of a target position. Both dose delivery verification and target positional accuracy affect dose delivery accuracy to a defined target. Hence there is a need to verify these two components in quality assurance protocol. The main intention of this paper is to present our dose delivery verification procedure using cylindrical wax phantom and accuracy assessment (target position) of stereotaxy using Geometric Phantom on Elekta's Precise linear accelerator for stereotactic installation

  7. Stereotactic radiotherapy in the liver hilum. Basis for future studies

    International Nuclear Information System (INIS)

    Zamboglou, C.; Messmer, M.B.; Momm, F.; Becker, G.

    2012-01-01

    A basis for future trials with stereotactic body radiotherapy (SBRT) for tumors of the liver hilum should be established. Thus, dosage concepts, planning processes, and dose constraints as well as technical innovations are summarized in this contribution. Methods On the background of our own data, the current literature was reviewed. The use of SBRT in the most common tumors of the liver hilum (pancreatic cancer and Klatskin tumors) was investigated. Dose constraints were calculated in 2 Gy standard fractionation doses. Results A total of 8 pilot or phase I/II studies about SBRT in the liver hilum were identified. In recent years, the SBRT technique has developed very quickly from classical stereotactic body frame radiotherapy to IGRT techniques including gating and tracking systems. In the studies using classical body frame technique, patients experienced considerable toxicities (duodenal ulcer/perforation) as compared to tolerable side effects in IGRT studies (<10% grade 3 and 4 toxicities). Dose constraints for duodenum, liver, kidneys, colon, and spinal cord were derived from the investigated studies. Survival and local tumor control data are very heterogeneous: median survival in these patients with locally advanced pancreatic or Klatskin tumors ranges between 5 and 32 months. Excellent local tumor control rates of about 80% over 24 months were achieved using SBRT. Conclusion Despite a few negative results, SBRT seems to be a promising technique in the treatment of tumors of the liver hilum. Highest precision in diagnostics, positioning, and irradiation as well as strict dose constraints should be applied to keep target volumes as small as possible and side effects tolerable. (orig.)

  8. Stereotactic radiosurgery versus whole-brain radiotherapy after intracranial metastasis resection : A systematic review and meta-analysis

    NARCIS (Netherlands)

    Lamba, Nayan; Muskens, Ivo S; DiRisio, Aislyn C; Meijer, Louise; Briceno, Vanessa; Edrees, Heba; Aslam, Bilal; Minhas, Sadia; Verhoeff, Joost J.C.; Kleynen, Catharina E.; Smith, Timothy R; Mekary, Rania A; Broekman, Marike L.

    2017-01-01

    Background: In patients with one to three brain metastases who undergo resection, options for post-operative treatments include whole-brain radiotherapy (WBRT) or stereotactic radiosurgery (SRS) of the resection cavity. In this meta-analysis, we sought to compare the efficacy of each post-operative

  9. The history of stereotactic radiosurgery and radiotherapy.

    Science.gov (United States)

    Lasak, John M; Gorecki, John P

    2009-08-01

    Stereotactic neurosurgery originated from the pioneering work of Horsley and Clarke, who developed a stereotactic apparatus to study the monkey brain in 1908. Spiegel and Wycis applied this technology to the human brain in 1947, which ultimately lead to the development of multiple stereotactic neurosurgical devices during the 1950s. It was Lars Leksell of Sweden, however, who envisioned stereotactic radiosurgery. Leksell developed the gamma knife to treat intracranial lesions in a noninvasive fashion. His work stimulated worldwide interest and created the field of stereotactic radiosurgery.

  10. Salvage surgery for local failures after stereotactic ablative radiotherapy for early stage non-small cell lung cancer

    NARCIS (Netherlands)

    N. Verstegen (Naomi); A.W.P.M. Maat (Alex); F.J. Lagerwaard (Frank); M.A. Paul (Marinus); M. Versteegh (Michel); J.J. Joosten (Joris); W. Lastdrager (Willem); E.F. Smit (Egbert); B.J. Slotman (Ben); J.J.M.E. Nuyttens (Joost); S. Senan (Suresh)

    2016-01-01

    markdownabstract__Introduction:__ The literature on surgical salvage, i.e. lung resections in patients who develop a local recurrence following stereotactic ablative radiotherapy (SABR), is limited. We describe our experience with salvage surgery in nine patients who developed a local recurrence

  11. Stereotactic body radiotherapy for renal cell cancer and pancreatic cancer. Literature review and practice recommendations of the DEGRO Working Group on Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Panje, Cedric; Andratschke, Nikolaus; Guckenberger, Matthias [Zurich University Hospital, Department of Radiation Oncology, Zurich (Switzerland); Brunner, Thomas B. [Freiburg University Hospital, Department of Radiation Oncology, Freiburg (Germany); Niyazi, Maximilian [University of Munich, Department of Radiation Oncology, Munich (Germany)

    2016-12-15

    This report of the Working Group on Stereotactic Radiotherapy of the German Society of Radiation Oncology (DEGRO) aims to provide a literature review and practice recommendations for stereotactic body radiotherapy (SBRT) of primary renal cell cancer and primary pancreatic cancer. A literature search on SBRT for both renal cancer and pancreatic cancer was performed with focus on prospective trials and technical aspects for clinical implementation. Data on renal and pancreatic SBRT are limited, but show promising rates of local control for both treatment sites. For pancreatic cancer, fractionated SBRT should be preferred to single-dose treatment to reduce the risk of gastrointestinal toxicity. Motion-compensation strategies and image guidance are paramount for safe SBRT delivery in both tumor entities. SBRT for renal cancer and pancreatic cancer have been successfully evaluated in phase I and phase II trials. Pancreatic SBRT should be practiced carefully and only within prospective protocols due to the risk of severe gastrointestinal toxicity. SBRT for primary renal cell cancer appears a viable option for medically inoperable patients but future research needs to better define patient selection criteria and the detailed practice of SBRT. (orig.) [German] Die Arbeitsgruppe ''Stereotaktische Radiotherapie'' der Deutschen Gesellschaft fuer Radioonkologie (DEGRO) legt eine Zusammenfassung der aktuellen Literatur und daraus resultierende Empfehlungen zur Durchfuehrung der stereotaktischen Strahlentherapie (SBRT) beim Nierenzellkarzinom und beim Pankreaskarzinom vor. Es erfolgte eine Literaturrecherche zur Evidenz der SBRT beim Nierenzell- und Pankreaskarzinom, wobei der Schwerpunkt auf prospektive Studien und technische Aspekte fuer die klinische Umsetzung gelegt wurde. Fuer die SBRT beim Pankreaskarzinom und Nierenzellkarzinom sind bisher nur wenige Studien veroeffentlicht worden, die jedoch konsistent eine hohe Rate an lokaler Tumorkontrolle

  12. Stereotactic Fractionated Radiotherapy in the Treatment of Juxtapapillary Choroidal Melanoma: The McGill University Experience

    International Nuclear Information System (INIS)

    Al-Wassia, Rolina; Dal Pra, Alan; Shun, Kitty; Shaban, Ahmed; Corriveau, Christine; Edelstein, Chaim; Deschenes, Jean; Ruo, Russel; Patrocinio, Horacio; Cury, Fabio L.B.; DeBlois, François; Shenouda, George

    2011-01-01

    Purpose: To report our experience with linear accelerator-based stereotactic fractionated radiotherapy in the treatment of juxtapapillary choroidal melanoma. Methods and Materials: We performed a retrospective review of 50 consecutive patients diagnosed with juxtapapillary choroidal melanoma and treated with linear accelerator-based stereotactic fractionated radiotherapy between April 2003 and December 2009. Patients with small to medium sized lesions (Collaborative Ocular Melanoma Study classification) located within 2 mm of the optic disc were included. The prescribed radiation dose was 60 Gy in 10 fractions. The primary endpoints included local control, enucleation-free survival, and complication rates. Results: The median follow-up was 29 months (range, 1–77 months). There were 31 males and 29 females, with a median age of 69 years (range, 30–92 years). Eighty-four percent of the patients had medium sized lesions, and 16% of patients had small sized lesions. There were four cases of local progression (8%) and three enucleations (6%). Actuarial local control rates at 2 and 5 years were 93% and 86%, respectively. Actuarial enucleation-free survival rates at 2 and 5 years were 94% and 84%, respectively. Actuarial complication rates at 2 and 5 years were 33% and 88%, respectively, for radiation-induced retinopathy; 9.3% and 46.9%, respectively, for dry eye; 12% and 53%, respectively, for cataract; 30% and 90%, respectively, for visual loss [Snellen acuity (decimal equivalent), <0.1]; 11% and 54%, respectively, for optic neuropathy; and 18% and 38%, respectively, for neovascular glaucoma. Conclusions: Linear accelerator-based stereotactic fractionated radiotherapy using 60 Gy in 10 fractions is safe and has an acceptable toxicity profile. It has been shown to be an effective noninvasive treatment for juxtapapillary choroidal melanomas.

  13. Clinical outcomes of a phase I/II study of 48 Gy of stereotactic body radiotherapy in 4 fractions for primary lung cancer using a stereotactic body frame

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Takayama, Kenji; Matsuo, Yukinori; Norihisa, Yoshiki; Mizowaki, Takashi; Sakamoto, Takashi; Sakamoto, Masato; Mitsumori, Michihide; Shibuya, Keiko; Araki, Norio; Yano, Shinsuke; Hiraoka, Masahiro

    2005-01-01

    Purpose: To evaluate the clinical outcomes of 48 Gy of three-dimensional stereotactic radiotherapy in four fractions for treating Stage I lung cancer using a stereotactic body frame. Methods and Materials: Forty-five patients who were treated between September 1998 and February 2004 were included in this study. Thirty-two patients had Stage IA lung cancer, and the other 13 had Stage IB lung cancer where tumor size was less than 4 cm in diameter. Three-dimensional treatment planning using 6-10 noncoplanar beams was performed to maintain the target dose homogeneity and to decrease the irradiated lung volume >20 Gy. All patients were irradiated using a stereotactic body frame and received four single 12 Gy high doses of radiation at the isocenter over 5-13 (median = 12) days. Results: Seven tumors (16%) completely disappeared after treatment (CR) and 38 tumors (84%) decreased in size by 30% or more (PR). Therefore, all tumors showed local response. During the follow-up of 6-71 (median = 30) months, no pulmonary complications greater than an National Cancer Institute-Common Toxicity Criteria of Grade 3 were noted. No other vascular, cardiac, esophageal, or neurologic toxicities were encountered. Forty-four (98%) of 45 tumors were locally controlled during the follow-up period. However, regional recurrences and distant metastases occurred in 3 and 5 of T1 patients and zero and 4 of T2 patients, respectively. For Stage IA lung cancer, the disease-free survival and overall survival rates after 1 and 3 years were 80% and 72%, and 92% and 83%, respectively, whereas for Stage IB lung cancer, the disease-free survival and overall survival rates were 92% and 71%, and 82% and 72%, respectively. Conclusion: Forty-eight Gy of 3D stereotactic radiotherapy in 4 fractions using a stereotactic body frame is useful for the treatment of Stage I lung tumors

  14. CyberKnife Radiosurgery in the Multimodal Management of Patients with Cushing Disease.

    Science.gov (United States)

    Moore, Justin M; Sala, Elisa; Amorin, Alvaro; Martinez, Hector; Bhowmik, Aprotim C; Chang, Steven D; Soltys, Scott G; Harsh, Griffith R; Katznelson, Laurence

    2018-04-01

    Surgery is the primary treatment for Cushing disease. When surgery is unsuccessful in normalizing hypercortisolism, adjuvant radiation, such as stereotactic radiosurgery, may be useful to improve biochemical control. This retrospective study included a cohort of consecutive patients treated with CyberKnife (CK) radiosurgery for active Cushing disease at Stanford Hospital and Clinics. As first-line treatment, all patients underwent transsphenoidal surgery with histologic demonstration of an adrenocorticotropic hormone-producing pituitary adenoma. CK was performed as adjuvant therapy for persistent or recurrent disease. The median time between surgery and CK was 14 ± 34 months. Before CK, median maximal diameter of tumors was 9 mm (range, 7-32 mm), with cavernous sinus invasion in all patients (100%) and abutment of the optic chiasm in 1 patient (14.2%). With an average follow-up of 55.4 months, normalization of hypercortisolism was achieved in 4 patients (57.1%): 2 patients (28.5%) achieved normalization of the hypothalamic-pituitary-adrenal axis without glucocorticoid replacement, and 2 patients developed hypoadrenalism (28.5%). The median time to biochemical remission was 12.5 months. Hypopituitarism occurred in only 1 patient (14.2%), and no patients had visual complications. Time between surgery and radiotherapy of Cushing disease, we demonstrate that CK is an effective treatment with rare complications. Copyright © 2018 Elsevier Inc. All rights reserved.

  15. Analysis of the factors affecting the safety of robotic stereotactic body radiation therapy for hepatocellular carcinoma patients

    Directory of Open Access Journals (Sweden)

    Liu XJ

    2017-11-01

    Full Text Available Xiaojie Liu,1,* Yongchun Song,1,* Ping Liang,2 Tingshi Su,2 Huojun Zhang,3 Xianzhi Zhao,3 Zhiyong Yuan,1 Ping Wang1 1Department of Radiotherapy,Tianjin Medical University Cancer Institute and Hospital, National Clinical Research Center for Cancer, Key Laboratory of Cancer Prevention and Therapy, Tianjin’s Clinical Research Center for Cancer, Tianjin, 2Cyberknife Center, Ruikang Hospital, Guangxi Traditional Chinese Medical University, Nanning, 3Department of Radiotherapy, Shanghai Changhai Hospital, Second Military Medical University, Shanghai, People’s Republic of China *These authors contributed equally to this work Objective: The objective of this study was to investigate the safety of robotic stereotactic body radiation therapy (SBRT for hepatocellular carcinoma (HCC patients and its related factors.Methods: A total of 74 HCC patients with Child–Turcotte–Pugh (CTP Class A were included in a multi-institutional, single-arm Phase II trial (NCT 02363218 between February 2013 and August 2016. All patients received SBRT treatment at a dose of 45 Gy/3f. The liver function was compared before and after SBRT treatment by the analysis of adverse hepatic reactions and changes in CTP classification.Results: After SBRT treatment, eight patients presented with decreases in CTP classification and 13 patients presented with ≥ grade 2 hepatic adverse reactions. For patients presenting with ≥ grade 2 hepatic adverse reactions, the total liver volume of ≤1,162 mL and a normal liver volume (total liver volume – gross tumor volume [GTV] of ≤1,148 mL were found to be independent risk factors and statistically significant (P<0.05.Conclusion: The total liver volume and normal liver volume are associated with the occurrence of ≥ grade 2 hepatic adverse reactions after SBRT treatment on HCC patients. Therefore, if the fractionated scheme of 45 Gy/3f is applied in SBRT for HCC patients, a total liver volume >1,162 mL and a normal liver

  16. Stereotactic Robotic Body Radiotherapy for Patients With Unresectable Hepatic Oligorecurrence.

    Science.gov (United States)

    Berkovic, Patrick; Gulyban, Akos; Nguyen, Paul Viet; Dechambre, David; Martinive, Philippe; Jansen, Nicolas; Lakosi, Ferenc; Janvary, Levente; Coucke, Philippe A

    2017-12-01

    The purpose of this study was to analyze local control (LC), liver progression-free survival (PFS), and distant PFS (DFS), overall survival (OS), and toxicity in a cohort of patients treated with stereotactic body radiotherapy (SBRT) with fiducial tracking for oligorecurrent liver lesions; and to evaluate the potential influence of lesion size, systemic treatment, physical and biologically effective dose (BED), treatment calculation algorithms and other parameters on the obtained results. Unoperable patients with sufficient liver function had [18F]-fluorodeoxyglucose-positron emission tomography-computed tomography and liver magnetic resonance imaging to confirm the oligorecurrent nature of the disease and to further delineate the gross tumor volume (GTV). An intended dose of 45 Gy in 3 fractions was prescribed on the 80% isodose and adapted if risk-related. Treatment was executed with the CyberKnife system (Accuray Inc) platform using fiducials tracking. Initial plans were recalculated using the Monte Carlo algorithm. Patient and treatment data were processed using the Kaplan-Meier method and log rank test for survival analysis. Between 2010 and 2015, 42 patients (55 lesions) were irradiated. The mean GTV and planning target volume (PTV) were 30.5 cc and 96.8 cc, respectively. Treatments were delivered 3 times per week in a median of 3 fractions to a PTV median dose of 54.6 Gy. The mean GTV and PTV D98% were 51.6 Gy and 51.2 Gy, respectively. Heterogeneity corrections did not influence dose parameters. After a median follow-up of 18.9 months, the 1- and 2-year LC/liver PFS/DFS/OS were 81.3%/55%/62.4%/86.9%, and 76.3%/42.3%/52%/78.3%, respectively. Performance status and histology had a significant effect on LC, whereas age (older than 65 years) marginally influenced liver PFS. Clinical target volume physical dose V45 Gy > 95%, generalized equivalent uniform dose (a = -30) > 45 Gy and a BED (α/β = 10) V105 Gy > 96% showed statistically significant effect on

  17. Stereotactic Ablative Radiotherapy for Oligometastatic Disease in Liver

    Directory of Open Access Journals (Sweden)

    Myungsoo Kim

    2014-01-01

    Full Text Available Liver metastasis in solid tumors, including colorectal cancer, is the most frequent and lethal complication. The development of systemic therapy has led to prolonged survival. However, in selected patients with a finite number of discrete lesions in liver, defined as oligometastatic state, additional local therapies such as surgical resection, radiofrequency ablation, cryotherapy, and radiotherapy can lead to permanent local disease control and improve survival. Among these, an advance in radiation therapy made it possible to deliver high dose radiation to the tumor more accurately, without impairing the liver function. In recent years, the introduction of stereotactic ablative radiotherapy (SABR has offered even more intensive tumor dose escalation in a few fractions with reduced dose to the adjacent normal liver. Many studies have shown that SABR for oligometastases is effective and safe, with local control rates widely ranging from 50% to 100% at one or two years. And actuarial survival at one and two years has been reported ranging from 72% to 94% and from 30% to 62%, respectively, without severe toxicities. In this paper, we described the definition and technical aspects of SABR, clinical outcomes including efficacy and toxicity, and related parameters after SABR in liver oligometastases from colorectal cancer.

  18. CBCT-Guided Rapid Arc for stereotactic ablative radiotherapy (SABR) in lung tumors

    Energy Technology Data Exchange (ETDEWEB)

    Fandino, J. M.; Silva, M. C.; Izquierdo, P.; Candal, A.; Diaz, I.; Fernandez, C.; Gesto, C.; Poncet, M.; Soto, M.; Triana, G.; Losada, C.; Marino, A.

    2013-07-01

    Stereotactic ablative radiotherapy has emerged as a standard treatment option for stage I non-small cell lung cancer in patients unfit for surgery, or who refuse surgery. An increasing number of prospective phase I/II trials, as well as large single and multicenter studies have reported local control rates to be in excess of 85% for early stage non-small cell lung cancer. Volumetric arc therapy RapidArc with tumor-based image guidance technique will be presented as well as our preliminary observations. (Author)

  19. Stability of percutaneously implanted markers for lung stereotactic radiotherapy

    DEFF Research Database (Denmark)

    Persson, Gitte Bjørnsen Fredberg; Josipovic, Mirjana; Von Der Recke, Peter

    2013-01-01

    The purpose of this study was to evaluate the stability of complex markers implanted into lung tumors throughout a course of stereotactic body radiotherapy (SBRT). Fifteen patients referred for lung SBRT were prospectively included. Radio-opaque markers were implanted percutaneously, guided...... mm in one or more registrations throughout the SBRT course. This is the first study to evaluate stability of complex markers implanted percutaneously into lung tumors for image guidance in SBRT. We conclude that the observed stability of marker position within the tumor indicates that complex markers...... can be used as surrogates for tumor position during a short course of SBRT as long as the uncertainties related to their position within the tumor are incorporated into the planning target volume....

  20. Complications from Stereotactic Body Radiotherapy for Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Kylie H. [School of Medicine, Case Western Reserve University, Cleveland, OH 44106 (United States); Okoye, Christian C.; Patel, Ravi B. [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106 (United States); Siva, Shankar [Division of Radiation Oncology and Cancer Imaging, Peter MacCallum Cancer Centre, East Melbourne, Victoria 3002 (Australia); Biswas, Tithi; Ellis, Rodney J.; Yao, Min; Machtay, Mitchell; Lo, Simon S., E-mail: Simon.Lo@uhhospitals.org [Department of Radiation Oncology, University Hospitals Seidman Cancer Center, Case Comprehensive Cancer Center, Case Western Reserve University, Cleveland, OH 44106 (United States)

    2015-06-15

    Stereotactic body radiotherapy (SBRT) has become a standard treatment option for early stage, node negative non-small cell lung cancer (NSCLC) in patients who are either medically inoperable or refuse surgical resection. SBRT has high local control rates and a favorable toxicity profile relative to other surgical and non-surgical approaches. Given the excellent tumor control rates and increasing utilization of SBRT, recent efforts have focused on limiting toxicity while expanding treatment to increasingly complex patients. We review toxicities from SBRT for lung cancer, including central airway, esophageal, vascular (e.g., aorta), lung parenchyma (e.g., radiation pneumonitis), and chest wall toxicities, as well as radiation-induced neuropathies (e.g., brachial plexus, vagus nerve and recurrent laryngeal nerve). We summarize patient-related, tumor-related, dosimetric characteristics of these toxicities, review published dose constraints, and propose strategies to reduce such complications.

  1. Complications from Stereotactic Body Radiotherapy for Lung Cancer

    Directory of Open Access Journals (Sweden)

    Kylie H. Kang

    2015-06-01

    Full Text Available Stereotactic body radiotherapy (SBRT has become a standard treatment option for early stage, node negative non-small cell lung cancer (NSCLC in patients who are either medically inoperable or refuse surgical resection. SBRT has high local control rates and a favorable toxicity profile relative to other surgical and non-surgical approaches. Given the excellent tumor control rates and increasing utilization of SBRT, recent efforts have focused on limiting toxicity while expanding treatment to increasingly complex patients. We review toxicities from SBRT for lung cancer, including central airway, esophageal, vascular (e.g., aorta, lung parenchyma (e.g., radiation pneumonitis, and chest wall toxicities, as well as radiation-induced neuropathies (e.g., brachial plexus, vagus nerve and recurrent laryngeal nerve. We summarize patient-related, tumor-related, dosimetric characteristics of these toxicities, review published dose constraints, and propose strategies to reduce such complications.

  2. Tumor shrinkage assessed by volumetric MRI in the long-term follow-up after stereotactic radiotherapy of meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Astner, Sabrina T.; Theodorou, Marilena; Dobrei-Ciuchendea, Mihaela; Kopp, Christine; Molls, Michael [Dept. of Radiotherapy and Radiooncology, Klinikum rechts der Isar, Technical Univ. of Munich (Germany); Auer, Florian [Dept. of Neuroradiology, Klinikum rechts der Isar, Technical Univ. of Munich (Germany); Grosu, Anca-Ligia [Dept. of Radiotherapy, Univ. Hospital Freiburg (Germany)

    2010-08-15

    Purpose: To evaluate tumor volume reduction in the follow-up of meningiomas after fractionated stereotactic radiotherapy (FSRT) or linac radiosurgery (RS) by using magnetic resonance imaging (MRI). Patients and Methods: In 59 patients with skull base meningiomas, gross tumor volume (GTV) was outlined on contrast-en-hanced MRI before and median 50 months (range 11-92 months) after stereotactic radiotherapy. MRI was performed as an axial three-dimensional gradient-echo T1-weighted sequence at 1.6 mm slice thickness without gap (3D-MRI). Results were compared to the reports of diagnostic findings. Results: Mean tumor size of all 59 meningiomas was 13.9 ml (0.8-62.9 ml) before treatment. There was shrinkage of the treated meningiomas in all but one patient. Within a median volumetric follow-up of 50 months (11-95 months), an absolute mean volume reduction of 4 ml (0-18 ml) was seen. The mean relative size reduction compared to the volume before radiotherapy was 27% (0-73%). Shrinkage measured by 3D-MRI was greater at longer time intervals after radiotherapy. The mean size reduction was 17%, 23%, and 30% (at < 24 months, 24-48 months, and 48-72 months). Conclusion: By using 3D-MRI in almost all patients undergoing radiotherapy of a meningioma, tumor shrinkage is detected. The data presented here demonstrate that volumetric assessment from 3D-MRI provides additional information to routinely used radiologic response measurements. After FSRT or RS, a mean size reduction of 25-45% can be expected within 4 years. (orig.)

  3. Radiotherapy in stereotactic conditions with CyberKnife of primitive or secondary hepatic lesions: lessons learnt by the Alexis-Vautrin Centre

    International Nuclear Information System (INIS)

    Taste-George, H.; Peiffert, D.

    2010-01-01

    The author report the experience gained on patients treated by irradiation in stereotactic conditions for primitive or secondary hepatic lesions. Thirty three patients have been treated, 22 suffering from secondary lesions and 11 from primitive lesions. The treatment technique is not much constraining for the patient, is not much toxic, and provides a high local tumour control. Short communication

  4. Successful treatment of tumor-induced osteomalacia due to an intracranial tumor by fractionated stereotactic radiotherapy.

    Science.gov (United States)

    Tarasova, Valentina D; Trepp-Carrasco, Alejandro G; Thompson, Robert; Recker, Robert R; Chong, William H; Collins, Michael T; Armas, Laura A G

    2013-11-01

    Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome, characterized by tumor secretion of fibroblast growth factor-23 (FGF23) causing hypophosphatemia due to renal phosphate wasting. TIO is usually caused by small, benign, difficult-to-localize, mesenchymal tumors. Although surgery with wide excision of tumor borders is considered the "gold standard" for definitive therapy, it can be associated with considerable morbidity depending on the location. To date, radiation therapy has not been considered as an effective treatment modality in TIO. A 67-year-old female presented with multiple nontraumatic fractures, progressive bone pain, and muscle weakness for 4 years. She was found to have biochemical evidence of urinary phosphate wasting with low serum phosphorus, low-normal serum calcium, normal 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D, and high serum FGF23 levels. TIO was diagnosed. Selective venous sampling for FGF23 confirmed that a 1.7-cm left frontal mass, radiographically similar to a meningioma, was the causative tumor. She declined surgery due to fear of complications and instead underwent fractionated stereotactic radiotherapy for 6 weeks. In less than 4 years after radiation therapy, she was successfully weaned off phosphorus and calcitriol, starting from 2 g of oral phosphorus daily and 1 μg of calcitriol daily. Her symptoms have resolved, and she has not had any new fractures. Stereotactic radiotherapy was an effective treatment modality for TIO in our patient. Fractionated stereotactic radiation therapy represents an alternative to surgery for patients with TIO who are not surgical candidates or who decline surgery.

  5. Successful Treatment of Tumor-Induced Osteomalacia due to an Intracranial Tumor by Fractionated Stereotactic Radiotherapy

    Science.gov (United States)

    Trepp-Carrasco, Alejandro G.; Thompson, Robert; Recker, Robert R.; Chong, William H.; Collins, Michael T.

    2013-01-01

    Context: Tumor-induced osteomalacia (TIO) is a rare paraneoplastic syndrome, characterized by tumor secretion of fibroblast growth factor-23 (FGF23) causing hypophosphatemia due to renal phosphate wasting. TIO is usually caused by small, benign, difficult-to-localize, mesenchymal tumors. Although surgery with wide excision of tumor borders is considered the “gold standard” for definitive therapy, it can be associated with considerable morbidity depending on the location. To date, radiation therapy has not been considered as an effective treatment modality in TIO. Objective: A 67-year-old female presented with multiple nontraumatic fractures, progressive bone pain, and muscle weakness for 4 years. She was found to have biochemical evidence of urinary phosphate wasting with low serum phosphorus, low-normal serum calcium, normal 25-hydroxyvitamin D and 1,25-dihydroxyvitamin D, and high serum FGF23 levels. TIO was diagnosed. Selective venous sampling for FGF23 confirmed that a 1.7-cm left frontal mass, radiographically similar to a meningioma, was the causative tumor. She declined surgery due to fear of complications and instead underwent fractionated stereotactic radiotherapy for 6 weeks. Results: In less than 4 years after radiation therapy, she was successfully weaned off phosphorus and calcitriol, starting from 2 g of oral phosphorus daily and 1 μg of calcitriol daily. Her symptoms have resolved, and she has not had any new fractures. Conclusions: Stereotactic radiotherapy was an effective treatment modality for TIO in our patient. Fractionated stereotactic radiation therapy represents an alternative to surgery for patients with TIO who are not surgical candidates or who decline surgery. PMID:24014621

  6. Development of re-locatable head frame system using hydraulic arms for fractionated stereotactic radiotherapy and CT evaluation of repositioning accuracy

    International Nuclear Information System (INIS)

    Kitamura, Masayuki; Kunieda, Etsuo; Kawaguchi, Osamu; Ando, Yutaka; Shigematsu, Naoyuki; Shiba, Toshiyuki; Kubo, Atsushi

    2002-01-01

    The purpose of this study was to develop a novel re-locatable head frame system consisting of a dental cast and hydraulic arms as an immobilization device for fractionated stereotactic radiotherapy and to evaluate the repositioning accuracy by measurement of landmark coordinates in repeated computed tomography (CT) examinations. The acrylic dental casts were customized for each patient. First the dental cast was attached to the upper jaw of the patient, then the dental cast was connected to a Leksell stereotactic frame, which was finally secured by two hydraulic arms. Since this system is compatible with the Leksell frame, stereotactic indicators could be used to obtain coordinates of anatomical landmarks of the head. Seven patients treated by fractionated stereotactic radiotherapy underwent repeated quality-assurance CTs during their treatment courses. We evaluated the coordinates of the short process of incus and the top of crista galli as reference points for evaluation of variation in a total of 26 repeat CT data sets, and then x, y, and z fluctuations relative to their positions in the treatment-planning CTs. The distances among the reference points of both processes of incus and the top of crista galli were calculated to evaluate the feasibility of the method. The distances were less than 0.5 mm on averages and less than 1 mm in the standard deviations. The respective fluctuations in the x, y and z directions were less than 1 mm in mean values and less than 2 mm in standard deviations. The fluctuations in distance were less than 2 mm on average and in standard deviations. The fluctuation of the center of three reference points was 0.7 mm on average and the rotation of the cranium was 1.0 degree in average. We concluded that our evaluation method is feasible and the reproducibility of the fixation system is acceptable for its routine use in stereotactic radiotherapy. (author)

  7. Stereotactic treatment. Definitions and literature overview

    International Nuclear Information System (INIS)

    Fontenla, D.P.

    2008-01-01

    The topics discussed include, among others, the following: Radiosurgery definitions; Stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT); Available uncertainties in SRS; Gamma knife; Linac-based SRS; Components of a radiosurgery system; Stereotactic hardware (brain lab); m3 linac attachment; Radiosurgery - clinical procedure; Cancer management; Rationale for SRT; Role of radiosurgery in the management of intracranial tumors; Indications for stereotactic SRS/SRT; Physical components required for SRS/SRT; Stereotactic patient set-up; Stereotactic CT scan for SRS; Physical components required for SRT: Relocatable head frame (GTC); Patient immobilization; Treatment planning system; Basic requirements for SRS dosimetry (Linac based); Stereotactic set-up QA (Linac); Stereotactic frames and QA; Beam dose measurements; Dose evaluation tools; Phantoms. (P.A.)

  8. Stereotactic radiotherapy of meningiomas. Symptomatology, acute and late toxicity

    Energy Technology Data Exchange (ETDEWEB)

    Henzel, M.; Gross, M.W.; Failing, T.; Strassmann, G.; Engenhart-Cabillic, R. [Dept. of Radiation Oncology, Univ. of Gisssen (Germany); Dept. of Radiation Oncology, Marburg Univ. (Germany); Hamm, K.; Surber, G.; Kleinert, G. [Dept. of Stereotactic Neurosurgery and Radiosurgery, Helios Klinikum Erfurt (Germany)

    2006-07-15

    Background and purpose: stereotactic radiosurgery (SRS) is well established in the treatment of skull base meningiomas, but this therapy approach is limited to small tumors only. The fractionated stereotactic radiotherapy (SRT) offers an alternative treatment option. This study aims at local control, symptomatology, and toxicity. Patients and methods: between 1997-2003, 224 patients were treated with SRT (n= 183), hypofractionated SRT (n = 30), and SRS (n = 11). 95/224 were treated with SRT/SRS alone. 129/224 patients underwent previous operations. Freedom from progression and overall survival, toxicity, and symptomatology were evaluated systematically. Additionally, tumor volume (TV) shrinkage was analyzed three-dimensionally within the planning system. Results: the median follow-up was 36 months (range, 12-100 months). Overall survival and freedom from progression for 5 years were 92.9% and 96.9%. Quantitative TV reduction was 26.2% and 30.3% 12 and 18 months after SRT/SRS (p < 0.0001). 95.9% of the patients improved their symptoms or were stable. Clinically significant acute toxicity (CTC III ) was rarely seen (2.5%). Clinically significant late morbidity (III -IV ) or new cranial nerve palsies did not occur. Conclusion: SRT offers an additional treatment option of high efficacy with only few side effects. In the case of large tumor size (> 4 ml) and adjacent critical structures (< 2 mm), SRT is highly recommended. (orig.)

  9. Multifractionated image-guided and stereotactic intensity-modulated radiotherapy of paraspinal tumors: A preliminary report

    International Nuclear Information System (INIS)

    Yamada, Yoshiya; Lovelock, D. Michael; Yenice, Kamil M.; Bilsky, Mark H.; Hunt, Margaret A.; Zatcky, Joan; Leibel, Steven A.

    2005-01-01

    Purpose: The use of image-guided and stereotactic intensity-modulated radiotherapy (IMRT) techniques have made the delivery of high-dose radiation to lesions within close proximity to the spinal cord feasible. This report presents clinical and physical data regarding the use of IMRT coupled with noninvasive body frames (stereotactic and image-guided) for multifractionated radiotherapy. Methods and Materials: The Memorial Sloan-Kettering Cancer Center (Memorial) stereotactic body frame (MSBF) and Memorial body cradle (MBC) have been developed as noninvasive immobilizing devices for paraspinal IMRT using stereotactic (MSBF) and image-guided (MBC) techniques. Patients were either previously irradiated or prescribed doses beyond spinal cord tolerance (54 Gy in standard fractionation) and had unresectable gross disease involving the spinal canal. The planning target volume (PTV) was the gross tumor volume with a 1 cm margin. The PTV was not allowed to include the spinal cord contour. All treatment planning was performed using software developed within the institution. Isocenter verification was performed with an in-room computed tomography scan (MSBF) or electronic portal imaging devices, or both. Patients were followed up with serial magnetic resonance imaging every 3-4 months, and no patients were lost to follow-up. Kaplan-Meier statistics were used for analysis of clinical data. Results: Both the MSBF and MBC were able to provide setup accuracy within 2 mm. With a median follow-up of 11 months, 35 patients (14 primary and 21 secondary malignancies) underwent treatment. The median dose previously received was 3000 cGy in 10 fractions. The median dose prescribed for these patients was 2000 cGy/5 fractions (2000-3000 cGy), which provided a median PTV V100 of 88%. In previously unirradiated patients, the median prescribed dose was 7000 cGy (5940-7000 cGy) with a median PTV V100 of 90%. The median Dmax to the cord was 34% and 68% for previously irradiated and never

  10. Clinical accuracy of ExacTrac intracranial frameless stereotactic system

    International Nuclear Information System (INIS)

    Ackerly, T.; Lancaster, C. M.; Geso, M.; Roxby, K. J.

    2011-01-01

    Purpose: In this paper, the authors assess the accuracy of the Brainlab ExacTrac system for frameless intracranial stereotactic treatments in clinical practice. Methods: They recorded couch angle and image fusion results (comprising lateral, longitudinal, and vertical shifts, and rotation corrections about these axes) for 109 stereotactic radiosurgery and 166 stereotactic radiotherapy patient treatments. Frameless stereotactic treatments involve iterative 6D image fusion corrections applied until the results conform to customizable pass criteria, theirs being 0.7 mm and 0.5 deg. for each axis. The planning CT slice thickness was 1.25 mm. It has been reported in the literature that the CT slices' thickness impacts the accuracy of localization to bony anatomy. The principle of invariance with respect to patient orientation was used to determine spatial accuracy. Results: The data for radiosurgery comprised 927 image pairs, of which 532 passed (pass ratio of 57.4%). The data for radiotherapy comprised 15983 image pairs, of which 10 050 passed (pass ratio of 62.9%). For stereotactic radiotherapy, the combined uncertainty of ExacTrac calibration, image fusion, and intrafraction motion was (95% confidence interval) 0.290-0.302 and 0.306-0.319 mm in the longitudinal and lateral axes, respectively. The combined uncertainty of image fusion and intrafraction motion in the anterior-posterior coordinates was 0.174-0.182 mm. For stereotactic radiosurgery, the equivalent ranges are 0.323-0.393, 0.337-0.409, and 0.231-0.281 mm. The overall spatial accuracy was 1.24 mm for stereotactic radiotherapy (SRT) and 1.35 mm for stereotactic radiosurgery (SRS). Conclusions: The ExacTrac intracranial frameless stereotactic system spatial accuracy is adequate for clinical practice, and with the same pass criteria, SRT is more accurate than SRS. They now use frameless stereotaxy exclusively at their center.

  11. Stereotactic ablative radiotherapy after concomitant chemoradiotherapy in non-small cell lung cancer: A TITE-CRM phase 1 trial.

    Science.gov (United States)

    Doyen, Jérôme; Poudenx, Michel; Gal, Jocelyn; Otto, Josiane; Guerder, Caroline; Naghavi, Arash O; Gérard, Anais; Leysalle, Axel; Cohen, Charlotte; Padovani, Bernard; Ianessi, Antoine; Schiappa, Renaud; Chamorey, Emmanuel; Bondiau, Pierre-Yves

    2018-05-01

    Platinum based chemoradiotherapy is the standard of care for inoperable non-small cell lung cancer (NSCLC). With evidence that NSCLC can have a dose dependent response with stereotactic ablative radiotherapy (SABR), we hypothesize that a SABR boost on residual tumor treated with chemoradiotherapy could increase treatment efficacy. The purpose of this study was to determine feasibility of such an approach. A prospective phase I trial was performed including 26 patients. Time-to-event continual reassessment method (TITE-CRM) was used for dose escalation which ranged from 3 × 7 to 3 × 12 Gy for the stereotactic boost, after 46 Gy (2 Gy per day) of chemoradiotherapy. Median follow-up was of 37.1 months (1.7-60.7), and 3, 4, 3, 3, 9 and 4 patients were included at the dose levels 1, 2, 3, 4, 5 and 6, respectively. During chemoradiotherapy, 9 patients experienced grade 3 toxicity. After stereotactic radiotherapy, 1 patient experienced an esophageal fistula (with local relapse) at the 3 × 11 Gy level, and 1 patient died from hemoptysis at the 3 × 12 Gy level. The 2-year rate of local control, locoregional free survival, metastasis-free survival, and overall survival was 70.3%, 55.5%, 44.5% and 50.8%, respectively. In the treatment of NSCLC with chemoradiotherapy followed by a stereotactic boost, the safe recommended dose in our protocol was a boost dose of 3 × 11 Gy. Copyright © 2018 Elsevier B.V. All rights reserved.

  12. (18)F-FDG PET during stereotactic body radiotherapy for stage I lung tumours cannot predict outcome : a pilot study

    NARCIS (Netherlands)

    Wiegman, Erwin M.; Pruim, Jan; Ubbels, Jan F.; Groen, Harry J. M.; Langendijk, Johannes A.; Widder, Joachim

    (18)F-Fluorodeoxyglucose positron emission tomography (FDG PET) has been used to assess metabolic response several months after stereotactic body radiotherapy (SBRT) for early-stage non-small cell lung cancer. However, whether a metabolic response can be observed already during treatment and thus

  13. A treatment planning comparison between a novel rotating gamma system and robotic linear accelerator based intracranial stereotactic radiosurgery/radiotherapy

    Science.gov (United States)

    Fareed, Muhammad M.; Eldib, Ahmed; Weiss, Stephanie E.; Hayes, Shelly B.; Li, Jinsheng; C-M Ma, Charlie

    2018-02-01

    To compare the dosimetric parameters of a novel rotating gamma ray system (RGS) with well-established CyberKnife system (CK) for treating malignant brain lesions. RGS has a treatment head of 16 cobalt-60 sources focused to the isocenter, which can rotate 360° on the ring gantry and swing 35° in the superior direction. We compared several dosimetric parameters in 10 patients undergoing brain stereotactic radiosurgery including plan normalization, number of beams and nodes for CK and shots for RGS, collimators used, estimated treatment time, D 2 cm and conformity index (CI) among two modalities. The median plan normalization for RGS was 56.7% versus 68.5% (p  =  0.002) for CK plans. The median number of shots from RGS was 7.5 whereas the median number of beams and nodes for CK was 79.5 and 46. The median collimator’s diameter used was 3.5 mm for RGS as compared to 5 mm for CK (p  =  0.26). Mean D 2 cm was 5.57 Gy for CyberKnife whereas it was 3.11 Gy for RGS (p  =  0.99). For RGS plans, the median CI was 1.4 compared to 1.3 for the CK treatment plans (p  =  0.98). The average minimum and maximum doses to optic chiasm were 21 and 93 cGy for RGS as compared to 32 and 209 cGy for CK whereas these were 0.5 and 364 cGy by RGS and 18 and 399 cGy by CK to brainstem. The mean V12 Gy for brain predicting for radionecrosis with RGS was 3.75 cm3 as compared to 4.09 cm3 with the CK (p  =  0.41). The dosimetric parameters of a novel RGS with a ring type gantry are comparable with CyberKnife, allowing its use for intracranial lesions and is worth exploring in a clinical setting.

  14. Linear accelerator based stereotactic radiosurgery with micro multi-leaf collimator : technological advancement in precision radiotherapy

    International Nuclear Information System (INIS)

    Dayananda, S.; Kinhikar, R.A.; Saju, Sherley; Deshpande, D.D.; Jalali, R.; Sarin, R.; Shrivastava, S.K.; Dinshaw, K.A.

    2003-01-01

    Stereotactic Radiosurgery (SRS) is an advancement on precision radiotherapy, in which stereo tactically guided localized high dose is delivered to the lesion (target) in a single fraction, while sparing the surrounding normal tissue. Radiosurgery has been used to treat variety of benign and malignant lesions as well as functional disorders in brain such as arteriovenous malformation (AVM), acoustic neuroma, solitary primary brain tumor, single metastasis, pituitary adenoma etc

  15. Prostate-specific antigen kinetics after primary stereotactic body radiation therapy using CyberKnife for localized prostate cancer

    Directory of Open Access Journals (Sweden)

    Yong Hyun Park

    2015-03-01

    Conclusions: PSA decline occurred rapidly in the first month, and then the rate of PSA decline fell off steadily over time throughout 2 years after treatment. Also, SBRT using CyberKnife leads to long-term favorable BCR-free survival in localized prostate cancer.

  16. Participating in an International Stereotactic Radiotherapy Patient Registry: The Establishment of Data Collection Pathways.

    Science.gov (United States)

    Yahya, Aylin; Arneric, Eva; Kernutt, Elizabeth; Baldacchino, Fiona; Haworth, Claire; Kedda, Mary-Anne; Tang, Colin; Bydder, Sean; Corica, Tammy

    2017-06-29

    Aim To describe data collection pathways and practical challenges experienced by an academic comprehensive cancer centre aiming to record clinical data for patients being treated with a novel radiotherapy treatment modality. Methods Various options to capture data from all patients treated with the CyberKnife Robotic Radiosurgery System at Sir Charles Gairdner Hospital (SCGH) in Western Australia were explored. An international multicenter web-based secure database established and maintained by the Radiosurgery Society the RSSearch® Patient Registry was selected. Data were collected and entered over four contiguous phases, with either opt-in or opt-out consent and the completion of Patient Reported Outcome questionnaires for specific sub-groups. Results Between April 2014 and June 2016, 461 patients at Sir Charles Gairdner Hospital were enrolled in the RSSearch® Patient Registry with the collection of over 17,500 data items. From 461 patients enrolled, 447 patients were treated with the CyberKnife Robotic Radiosurgery System. The majority of patients were treated for either a malignant primary (43.2%) or metastatic disease (39.4%). The establishment of matrix organisational processes for data collection led to the development of improved workflow patterns and data collection pathways. Conclusions This article describes the processes developed by a single centre to establish an efficient system for data collection and participation in an international registry. The opt-out approach was more efficient in terms of patient recruitment compared to the informed-consent method used in earlier phases. The experience of this single centre may help inform other institutions considering data collection options for assessments of new or novel treatments.

  17. Case report of a near medical event in stereotactic radiotherapy due to improper units of measure from a treatment planning system

    International Nuclear Information System (INIS)

    Gladstone, D. J.; Li, S.; Jarvis, L. A.; Hartford, A. C.

    2011-01-01

    Purpose: The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. Methods: Using pretreatment imaging, the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. Results: Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. Conclusions: The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.

  18. Case report of a near medical event in stereotactic radiotherapy due to improper units of measure from a treatment planning system

    Energy Technology Data Exchange (ETDEWEB)

    Gladstone, D. J.; Li, S.; Jarvis, L. A.; Hartford, A. C. [Division of Radiation Oncology, Department of Medicine, Dartmouth-Hitchcock Medical Center, Norris Cotton Cancer Center, Lebanon, New Hampshire 03756 (United States); Division of Radiation Oncology, Department of Medicine, Dartmouth-Hitchcock Medical Center, Norris Cotton Cancer Center, Lebanon, New Hampshire 03756 and Department of Radiation Oncology, Temple University Hospital, Philadelphia, Pennsylvania 19104 (United States); Division of Radiation Oncology, Department of Medicine, Dartmouth-Hitchcock Medical Center, Norris Cotton Cancer Center, Lebanon, New Hampshire 03756 (United States)

    2011-07-15

    Purpose: The authors hereby notify the Radiation Oncology community of a potentially lethal error due to improper implementation of linear units of measure in a treatment planning system. The authors report an incident in which a patient was nearly mistreated during a stereotactic radiotherapy procedure due to inappropriate reporting of stereotactic coordinates by the radiation therapy treatment planning system in units of centimeter rather than in millimeter. The authors suggest a method to detect such errors during treatment planning so they are caught and corrected prior to the patient positioning for treatment on the treatment machine. Methods: Using pretreatment imaging, the authors found that stereotactic coordinates are reported with improper linear units by a treatment planning system. The authors have implemented a redundant, independent method of stereotactic coordinate calculation. Results: Implementation of a double check of stereotactic coordinates via redundant, independent calculation is simple and accurate. Use of this technique will avoid any future error in stereotactic treatment coordinates due to improper linear units, transcription, or other similar errors. Conclusions: The authors recommend an independent double check of stereotactic treatment coordinates during the treatment planning process in order to avoid potential mistreatment of patients.

  19. Extracranial doses during stereotactic radiosurgery and fractionated stereotactic radiotherapy measured with thermoluminescent dosimeter in vivo

    Energy Technology Data Exchange (ETDEWEB)

    Kim, I.H.; Lim, D.H.; Kim, S.; Hong, S.; Kim, B.K.; Kang, W-S.; Wu, H.G.; Ha, S.W.; Park, C.I. [Seoul National University College of Medicine, Department of Therapeutic Radiology (Korea)

    2000-05-01

    Recently the usage of 3-dimensional non-coplanar radiotherapy technique is increasing. We measured the extracranial dose and its distribution g the above medical procedures to estimate effect of exit doses of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (FSRT) of the intracranial target lesions using a linac system developed in our hospital. Among over hundred patients who were treated with SRS or FSRT from 1995 to 1998, radiation dosimetry data of 15 cases with SRS and 20 cases with FSRT were analyzed. All patients were adults. Of SRS cases, 11 were male and 4 were female. Vascular malformation cases were 9, benign tumors were 3, and malignant tumors were 3. Of FSRT cases, males were 12 and females were 8. Primary malignant brain tumors were 5, benign tumors were 6, and metastatic brain tumors were 10. Doses were measured with lithium fluoride TLD chips (7.5% Li-6 and 92.5% Li-7; TLD-100, Harshaw/Filtrol, USA). The chips were attached patient's skin at the various extracranial locations during SRS or FSRT. For SRS, 14-25 Gy were delivered with 1-2 isocenters using 12-38 mm circular tertiary collimators with reference to 50-80% isodose line conforming at the periphery of the target lesions. For FSRT, 5-28 fractions were used to deliver 9-56 Gy to periphery with dose maximum of 10-66 Gy. Both procedures used 6 MV X-ray generated from Clinac-18 (Varian, USA). For SRS procedures, extracranial surface doses (relative doses) were 8.07{+-}4.27 Gy (0.31{+-}0.16% Mean{+-}S.D.) at the upper eyelids, 6.13{+-}4.32 Gy (0.24{+-}0.16%) at the submental jaw, 7.80{+-}5.44 Gy (0.33{+-}0.26%) at thyroid, 1.78{+-}0.64 Gy (0.07{+-}0.02%) at breast, 0.75{+-}0.38 Gy (0.03{+-}0.02%) at umbilicus, 0.40{+-}0.07 Gy (0.02{+-}0.01%) at perineum, and 0.46{+-}0.39 Gy (0.02{+-}0.01%) at scrotum. Thus the farther the distance from the brain, the less the dose to the location. In overall the doses were less than 0.3% and thus less detrimental. For FSRT procedures

  20. Initial clinical results of linac stereotactic radiosurgery (SRS) and stereotactic radiotherapy (SRT) for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; McL Black, Peter; Loeffler, Jay S.

    1997-01-01

    Purpose: To evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor control and toxicity of the treatment, thus evaluate the feasibility of these technique for the treatment of pituitary adenomas. Subjects and Methods: 48 patients with either inoperable, recurrent or residual pituitary adenoma who underwent either SRS or SRT at the Brigham and Women's Hospital between 9/89 and 9/95 were analyzed. Of these, 18 received treatment with SRS, and 30 received SRT. SRS was contraindicated for the patients in whom the minimal distance of the target and optic chiasm or optic nerve was less than 5 mm. Patient characteristics were similar in the two groups, with the exception of tumor volume and previous irradiation. Median tumor volumes were 1.8 cm 3 and 7.7 cm 3 for SRS and SRT, respectively. Three of the SRS and none of the SRT patients had a history of previous external radiation therapy. Both SRS and SRT were performed by the use of dedicated stereotactic 6-MV linear accelerator with a treatment plan designed using a dedicated software. Doses were prescribed to the isodose distribution that covered the identified target. Dose and normalization used for SRS varied from 1000 cGy at 85 % isodose line to 1800 cGy at 80 % isodose line. For SRT patients, total dose of 4500 cGy was normalized at 90 or 95 % isodose line and this was delivered in 25 fractions of 180 cGy daily dose. Results: Local control: There was 1 case of local failure in each of SRS and SRT series (median follow up 42.5 months and 22 month, respectively). CNS adverse effects: There were 3 SRS cases in whom a ring enhancement in the temporal lobe was observed in follow-up MRI. (median follow up 32 months). Of these, one resolved spontaneously, whereas the other 2 lesion persisted and considered to be radiation necrosis. None of them required surgical intervention to date. These were observed in the

  1. Cine Computed Tomography Without Respiratory Surrogate in Planning Stereotactic Radiotherapy for Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Riegel, Adam C. B.A.; Chang, Joe Y.; Vedam, Sastry S.; Johnson, Valen; Chi, Pai-Chun Melinda; Pan, Tinsu

    2009-01-01

    Purpose: To determine whether cine computed tomography (CT) can serve as an alternative to four-dimensional (4D)-CT by providing tumor motion information and producing equivalent target volumes when used to contour in radiotherapy planning without a respiratory surrogate. Methods and Materials: Cine CT images from a commercial CT scanner were used to form maximum intensity projection and respiratory-averaged CT image sets. These image sets then were used together to define the targets for radiotherapy. Phantoms oscillating under irregular motion were used to assess the differences between contouring using cine CT and 4D-CT. We also retrospectively reviewed the image sets for 26 patients (27 lesions) at our institution who had undergone stereotactic radiotherapy for Stage I non-small-cell lung cancer. The patients were included if the tumor motion was >1 cm. The lesions were first contoured using maximum intensity projection and respiratory-averaged CT image sets processed from cine CT and then with 4D-CT maximum intensity projection and 10-phase image sets. The mean ratios of the volume magnitude were compared with intraobserver variation, the mean centroid shifts were calculated, and the volume overlap was assessed with the normalized Dice similarity coefficient index. Results: The phantom studies demonstrated that cine CT captured a greater extent of irregular tumor motion than did 4D-CT, producing a larger tumor volume. The patient studies demonstrated that the gross tumor defined using cine CT imaging was similar to, or slightly larger than, that defined using 4D-CT. Conclusion: The results of our study have shown that cine CT is a promising alternative to 4D-CT for stereotactic radiotherapy planning

  2. A new non-invasive and relocatable immobilization frame for fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Theodorou, K.; Kappas, C.; Tsokas, C.

    1998-01-01

    Purpose: A newly developed non-invasive immobilization frame for stereotactic radiotherapy is presented, which is intended to be used for both imaging (computed tomography (CT) and angiography) and radiotherapeutic procedures. Materials and methods: The frame is made of duraluminium so as to be stable and light and it has an elliptical shape. The immobilization is achieved using three stable locations on the patient's head, i.e. the upper dentition, the nose and the back of the neck. The fixation on the three locations ensures complete immobilization in all directions. Results: The immobilization frame can be fitted as many times as is needed to most heads. In order to assess the accuracy of relocation, repeated fittings on two volunteers and on 22 patients undergoing stereotactic treatment were performed (more than 200 mountings in total), which showed maximum anterior-posterior, inferior-superior and lateral reproducibility in positioning of less than 1 mm in all cases. Conclusions and discussion: The in-house-constructed stereotactic frame is simple to use, easily made, non-invasive, relocatable and well tolerated by the patients, providing the possibility of multiple fractions. The major advantage of using such a non-invasive stereotactic frame is the flexibility in timing the different diagnostic procedures (CT and angiography) as well as providing the possibility to extend the use to large brain lesions (treatment without an additional collimator) where a high precision is also required. It also offers significant labour and cost saving over the invasive frames and the majority of the non-invasive frames. To date, 22 patients with ages varying between 12 and 70 years have been treated using this method. (Copyright (c) 1998 Elsevier Science B.V., Amsterdam. All rights reserved.)

  3. Current Status of Stereotactic Ablative Radiotherapy (SABR for Early-stage 
Non-small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Anhui SHI

    2016-06-01

    Full Text Available High level evidence from randomized studies comparing stereotactic ablative radiotherapy (SABR to surgery is lacking. Although the results of pooled analysis of two randomized trials for STARS and ROSEL showed that SABR is better tolerated and might lead to better overall survival than surgery for operable clinical stage I non-small cell lung cancer (NSCLC, SABR, however, is only recommended as a preferred treatment option for early stage NSCLC patients who cannot or will not undergo surgery. We, therefore, are waiting for the results of the ongoing randomized studies [Veterans affairs lung cancer surgery or stereotactic radiotherapy in the US (VALOR and the SABRTooth study in the United Kingdom (SABRTooths]. Many retrospective and case control studies showed that SABR is safe and effective (local control rate higher than 90%, 5 years survival rate reached 70%, but there are considerable variations in the definitions and staging of lung cancer, operability determination, and surgical approaches to operable lung cancer (open vs video-assisted. Therefore, it is difficult to compare the superiority of radiotherapy and surgery in the treatment of early staged lung cancer. Most studies demonstrated that the efficacy of the two modalities for early staged lung cancer is equivalent; however, due to the limited data, the conclusions from those studies are difficult to be evidence based. Therefore, the controversies will be focusing on the safety and invasiveness of the two treatment modalities. This article will review the ongoing debate in light of these goals.

  4. Available evidence on re-irradiation with stereotactic ablative radiotherapy following high-dose previous thoracic radiotherapy for lung malignancies.

    Science.gov (United States)

    De Bari, Berardino; Filippi, Andrea Riccardo; Mazzola, Rosario; Bonomo, Pierluigi; Trovò, Marco; Livi, Lorenzo; Alongi, Filippo

    2015-06-01

    Patients affected with intra-thoracic recurrences of primary or secondary lung malignancies after a first course of definitive radiotherapy have limited therapeutic options, and they are often treated with a palliative intent. Re-irradiation with stereotactic ablative radiotherapy (SABR) represents an appealing approach, due to the optimized dose distribution that allows for high-dose delivery with better sparing of organs at risk. This strategy has the goal of long-term control and even cure. Aim of this review is to report and discuss published data on re-irradiation with SABR in terms of efficacy and toxicity. Results indicate that thoracic re-irradiation may offer satisfactory disease control, however the data on outcome and toxicity are derived from low quality retrospective studies, and results should be cautiously interpreted. As SABR may be associated with serious toxicity, attention should be paid for an accurate patients' selection. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Superior target delineation for stereotactic body radiotherapy of bone metastases from renal cell carcinoma on MRI compared to CT

    NARCIS (Netherlands)

    Prins, Fieke M.; Van Der Velden, Joanne M.; Gerlich, Anne S.; Kotte, Alexis N.T.J.; Eppinga, Wietse S.C.; Kasperts, Nicolien; Verlaan, Jorrit J.; Pameijer, Frank A.; Kerkmeijer, Linda G.W.

    2017-01-01

    Background: In metastatic renal cell carcinoma (mRCC) there has been a treatment shift towards targeted therapy, which has resulted in improved overall survival. Therefore, there is a need for better local control of the tumor and its metastases. Image-guided stereotactic body radiotherapy (SBRT) in

  6. Quality assurance in fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Warrington, A.P.; Laing, R.W.; Brada, M.

    1994-01-01

    The recent development of fractionated stereotactic radiotherapy (SRT), which utilises the relocatable Gill-Thomas-Cosman frame (GTC 'repeat localiser'), requires comprehensive quality assurance (QA). This paper focuses on those QA procedures particularly relevant to fractionated SRT treatments, and which have been derived from the technique used at the Royal Marsden Hospital. They primarily relate to the following: (i) GTC frame fitting, initially in the mould room, and then at each imaging session and treatment fraction; (ii) checking of the linear accelerator beam geometry and alignment lasers; and (iii) setting up of the patient for each fraction of treatment. The precision of the fractionated technique therefore depends on monitoring the GTC frame relocation at each fitting, checking the accuracy of the radiation isocentre of the treatment unit, its coincidence with the patient alignment lasers and the adjustments required to set the patient up accurately. The results of our quality control checks show that setting up to a mean radiation isocentre using precisely set-up alignment lasers can be achievable to within 1 mm accuracy. When this is combined with a mean GTC frame relocatability of 1 mm on the patient, a 2-mm allowance between the prescribed isodose surface and the defined target volume is a realistic safety margin for this technique

  7. Results of fractionated stereotactic radiotherapy with linear accelerator

    Energy Technology Data Exchange (ETDEWEB)

    Aoki, Masahiko; Watanabe, Sadao [Aomori Prefectural Central Hospital (Japan); Mariya, Yasushi [and others

    1997-03-01

    A lot of clinical data about stereotactic radiotherapy (SRT) were reported, however, standard fractionated schedules were not shown. In this paper, our clinical results of SRT, 3 fractions of 10 Gy, are reported. Between February 1992 and March 1995, we treated 41 patients with 7 arteriovenous malformations and 41 intracranial tumors using a stereotactic technique implemented by a standard 10MV X-ray linear accelerator. Average age was 47.4 years (range 3-80 years) and average follow-up time was 16.7 months (range 3.5-46.1 months). The patients received 3 fractions of 10 Gy for 3 days delivered by multiple arc narrow beams under 3 cm in width and length. A three-pieces handmade shell was used for head fixation without any anesthetic procedures. Three-dimensional treatment planning system (Focus) was applied for the dose calculation. All patients have received at least one follow-up radiographic study and one clinical examination. In four of the 7 patients with AVM the nidus has become smaller, 9 of the 21 patients with benign intracranial tumors and 9 of the 13 patients with intracranial malignant tumors have shown complete or partial response to the therapy. In 14 patients, diseases were stable or unevaluable due to the short follow-up time. In 5 patients (3 with astrocytoma, 1 each with meningioma and craniopharyngioma), diseases were progressive. Only 1 patient with falx meningioma had minor complication due to the symptomatic brain edema around the tumor. Although, further evaluation of target control (i.e. tumor and nidus) and late normal tissue damage is needed, preliminary clinical results indicate that SRT with our methods is safe and effective. (author)

  8. Single-fraction stereotactic radiotherapy: a dose-response analysis of arteriovenous malformation obliteration

    International Nuclear Information System (INIS)

    Touboul, Emmanuel; Al Halabi, Assem; Buffat, Laurent; Merienne, Louis; Huart, Judith; Schlienger, Michel; Lefkopoulos, Dimitrios; Mammar, Hamid; Missir, Odile; Meder, Jean-Francois; Laurent, Alex; Housset, Martin

    1998-01-01

    Purpose: Stereotactic radiotherapy delivered in a high-dose single fraction is an effective technique to obliterate intracranial arteriovenous malformations (AVM). To attempt to analyze the relationships between dose, volume, and obliteration rates, we studied a group of patients treated using single-isocenter treatment plans. Methods and Materials: From May 1986 to December 1989, 100 consecutive patients with angiographically proven AVM had stereotactic radiotherapy delivered as a high-dose single fraction using a single-isocenter technique. Distribution according to Spetzler-Martin grade was as follows: 79 grade 1-3, three grade 4, 0 grade 5, and 18 grade 6. The target volume was spheroid in 74 cases, ellipsoid in 11, and large and irregular in 15. The targeted volume of the nidus was estimated using two-dimensional stereotactic angiographic data and, calculated as an ovoid-shaped lesion, was 1900 ± 230 mm 3 (median 968 mm 3 ; range 62-11, 250 mm 3 ). The mean minimum target dose (D min ) was 19 ± 0.6 Gy (median 20 Gy; range: 3-31.5). The mean volume within the isodose which corresponded to the minimum target dose was 2500 ± 300 mm 3 (median 1200 mm 3 ; range 75-14 900 mm 3 ). The mean maximum dose (D max ) was 34.5 ± 0.5 Gy (median 35 Gy; range 15-45). The mean angiographic follow-up was 42 ± 2.3 months (median 37.5; range 7-117). Results: The absolute obliteration rate was 51%. The 5-year actuarial obliteration rate was 62.5 ± 7%. After univariate analysis, AVM obliteration was influenced by previous surgery (p = 0.0007), D min by steps of 5 Gy (p = 0.005), targeted volume of the nidus (≤968 mm 3 vs. >968 mm 3 ; p = 0.015), and grade according to Spetzler-Martin (grade 1-3 vs. grade 4-6; p = 0.011). After multivariate analysis, the independent factors influencing AVM obliteration were the D min [relative risk (RR) 1.9; 95% confidence interval (CI) 1.4-2.5; p min but does not seem to be influenced by D max and the targeted volume of the nidus

  9. A computer-controlled high resolution micro-multi-leaf collimator for stereotactic conformal radio-therapy

    International Nuclear Information System (INIS)

    Schlegel, Wolfgang; Pastyr, Otto; Kubesch, Rudolf; Diemer, Torsten; Kuester, Gunnilla; Rhein, Bernhard; Hoever, Karl-Heinz

    1997-01-01

    Purpose/Objective In stereotactic conformal radiotherapy of irregularly shaped lesions, either multi-isocentric convergent beam treatment techniques with circular collimators or irregular shaped beams are being used. While the treatment technique with multiple isocenters has the disadvantage of producing inhomogeneous dose distributions, the use of irregular shaped fields is not yet satisfying from a technical point of view: Cerrobend blocking or the use of static micro MLCs need a long preparation time and only allow static treatment techniques, MLC collimators which are commercially available in connection with modern LINACs have leaf-thickness of at least 1 cm which is too coarse for stereotactic radiotherapy of lesions in the brain and head and neck area. For this reason, we developed a computer controlled micro-MLC with technical specifications matched to the needs of stereotactic radiotherapy and radiosurgery. Materials and Methods The mechanical specifications of the computer controlled micro-MLC were derived from our experience with stereotactic treatment techniques, from the requirement that the MLC has to be attachable as an external device to the accessory holders of standard LINACs, including cost considerations, dosimetric measurements as well as Monte Carlo calculations. The Micro-MLC is controlled by an electronic equipment consisting of a standard PC under Windows 95, an interface board, 14 Micro-controller boards, a verification system and 80 driving units equipped with DC motors and potentiometers. The control program has calibrating, operating, visualizing and test options. Irregular field data are transferred from the treatment planning computer to the control PC and distributed to the micro-controllers, which in parallel are driving three leaves each. Beside the special control unit, we are currently investigating whether the electronics of commercially available integrated large field MLCs can also be used for operating the Micro-MLC. Results

  10. Optimization of total arc degree for stereotactic radiotherapy by using integral biologically effective dose and irradiated volume

    International Nuclear Information System (INIS)

    Lim, Do Hoon; Kim, Dae Yong; Lee, Myung Za; Chun, Ha Chung

    2001-01-01

    To find the optimal values of total arc degree to protect the normal brain tissue from high dose radiation in stereotactic radiotherapy planning. With Xknife-3 planning system and 4 MV linear accelerator, the authors planned under various values of parameters. One isocenter, 12, 20, 30, 40, 50, and 60 mm of collimator diameters, 100 deg, 200 deg, 300 deg, 400 deg, 500 deg, 600 deg, of total arc degrees, and 30 deg or 45 deg of arc intervals were used. After the completion of planning, the plans were compared each other using V 50 (the volume of normal brain that is delivered high dose radiation) and integral biologically effective dose. At 30 deg of arc interval, the values of V 50 had the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval, up to 400 deg of total arc degree, the values of V 50 decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. At 30 deg of arc interval, integral biologically effective dose showed the decreased pattern with the increase of total arc degree in any collimator diameter. At 45 deg arc interval with less than 40 mm collimator diameter, the integral biologically effective dose decreased with the increase of total arc degree, but with 50 and 60 mm of collimator diameters, up to 400 deg of total arc degree, integral biologically effective dose decreased with the increase of total arc degree, but at 500 deg and 600 deg of total arc degrees, the values increased. In the stereotactic radiotherapy planning for brain lesions, planning with 400 deg of total arc degree is optimal. Especially, when the larger collimator more than 50 mm diameter should be used, the uses of 500 deg and 600 deg of total arc degrees make the increase of V 50 and integral biologically effective dose, Therefore stereotactic radiotherapy planning using 400 deg of total arc degree can increase the therapeutic ratio and produce the effective outcome

  11. Image guidance quality assurance of a G4 CyberKnife robotic stereotactic radiosurgery system

    International Nuclear Information System (INIS)

    Pantelis, E; Antypas, C; Petrokokkinos, L

    2009-01-01

    The image guidance of a CyberKnife robotic radiosurgery system was quality controlled, including the overall performance of the target locating subsystem and the performance of the x-ray generators and flat panel digital cameras subcomponents. Accuracy and precision of the kV and exposure time settings of the x-ray generators, linearity of the x-ray output, spatial resolution and geometrical distortion of the acquired x-ray images were measured. Total accuracy and precision of the target locating subsystem in defining the position of an anthropomorphic head and neck phantom placed on treatment couch was also measured. Accuracy and precision of the kV as well as exposure time settings and linearity of the x-ray output were found within the acceptance limits suggested in diagnostic radiology. The acquired x-ray images were found to depict the shapes of the imaging objects without any geometrical distortion, being able to resolve differences in the features of imaging objects with critical frequency of 1.3 lp/mm and 1.5 lp/mm for camera A and B, respectively. Total target locating system accuracy was found within 0.2 mm and 0.2 deg. in translations and rotations, respectively. Corresponding precision was found lower than 0.5%. These findings render the target locating subsystem of the CyberKnife capable of accurately registering the patient to treatment position and monitoring patient's movement during treatment delivery.

  12. Stereotactic body radiotherapy for primary renal cell carcinoma and adrenal metastases.

    Science.gov (United States)

    Kothari, Gargi; Louie, Alexander V; Pryor, David; Vela, Ian; Lo, Simon S; Teh, Bin S; Siva, Shankar

    2017-09-01

    The incidence of renal cell carcinoma (RCC) and metastatic adrenal lesions continues to rise and present evolving complexities in terms of management. Technical challenges in treatment delivery are compounded by the setting of an ageing patient population with multiple medical co-morbidities. While the standard of care treatment for both primary RCC and oligometastatic adrenal lesions has typically been surgery, a number of patients may be medically or surgically inoperable, and for whom alternative options require consideration. Additionally, in metastatic disease, surgery presents an invasive option, sometimes with unacceptable risks of perioperative morbidity and therefore is considered a less desirable option to some. Stereotactic body radiotherapy (SBRT) is an established radiotherapy technique that is rapidly being incorporated into many radiotherapy departments, particu-larly with the increasing availability and capabilities of modern linear accelerators to deliver precise image guided treatment. There are considerable advantages of SBRT including its ability to provide a non-invasive ablative treatment with very few treatment sessions, with emerging evidence showing promising rates of local control (LC) and low associated mor-bidity. This review details the use of SBRT for primary RCC as well as adrenal metastases, focusing on issues including patient selection, technical considerations, and patient out-comes. Furthermore, this review explores some recent insights into the radiobiology of RCC, the immunomodulatory effects of SBRT, and the use of systemic agents with SBRT.

  13. Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non-Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?

    Energy Technology Data Exchange (ETDEWEB)

    Onishi, Hiroshi, E-mail: honishi@yamanashi.ac.jp [School of Medicine, Yamanashi University, Yamanashi (Japan); Shirato, Hiroki [School of Medicine, Hokkaido University, Sapporo (Japan); Nagata, Yasushi [School of Medicine, Hiroshima University, Hiroshima (Japan); Hiraoka, Masahiro [School of Medicine, Kyoto University, Kyoto (Japan); Fujino, Masaharu [School of Medicine, Hokkaido University, Sapporo (Japan); School of Medicine, Yamanashi University, Yamanashi (Japan); Gomi, Kotaro [Cancer Institute Suwa Red-Cross Hospital, Suwa (Japan); Karasawa, Katsuyuki [Tokyo Metropolitan Komagome Hospital, Tokyo (Japan); Hayakawa, Kazushige; Niibe, Yuzuru [Kitasato University, Kanagawa (Japan); Takai, Yoshihiro [School of Medicine, Hirosaki University, Hirosaki (Japan); Kimura, Tomoki [School of Medicine, Kagawa University, Hiroshima (Japan); Takeda, Atsuya [Ofuna Chuo Hospital, Kanagawa (Japan); Ouchi, Atsushi [Keijinkai Hospital, Sapporo (Japan); Hareyama, Masato [Sapporo Medical University, Sapporo (Japan); Kokubo, Masaki [Institute of Biomedical Research and Innovation, Kobe (Japan); Kozuka, Takuyo [School of Cancer Institute Ariake Hospital, Tokyo (Japan); Arimoto, Takuro [Kitami Red Cross Hospital, Kitami (Japan); Hara, Ryusuke [National Institute of Radiological Science, Chiba (Japan); Itami, Jun [National Cancer Center, Tokyo (Japan); Araki, Tsutomu [School of Medicine, Yamanashi University, Yamanashi (Japan)

    2011-12-01

    Purpose: To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non-small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Patients and Methods: Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n = 65; T2N0M0, n = 22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45-72.5 Gy at the isocenter, administered in 3-10 fractions. Median calculated biological effective dose was 116 Gy (range, 100-141 Gy). Data were collected and analyzed retrospectively. Results: During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Conclusion: Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.

  14. Stereotactic Body Radiotherapy (SBRT) for Operable Stage I Non–Small-Cell Lung Cancer: Can SBRT Be Comparable to Surgery?

    International Nuclear Information System (INIS)

    Onishi, Hiroshi; Shirato, Hiroki; Nagata, Yasushi; Hiraoka, Masahiro; Fujino, Masaharu; Gomi, Kotaro; Karasawa, Katsuyuki; Hayakawa, Kazushige; Niibe, Yuzuru; Takai, Yoshihiro; Kimura, Tomoki; Takeda, Atsuya; Ouchi, Atsushi; Hareyama, Masato; Kokubo, Masaki; Kozuka, Takuyo; Arimoto, Takuro; Hara, Ryusuke; Itami, Jun; Araki, Tsutomu

    2011-01-01

    Purpose: To review treatment outcomes for stereotactic body radiotherapy (SBRT) in medically operable patients with Stage I non–small-cell lung cancer (NSCLC), using a Japanese multi-institutional database. Patients and Methods: Between 1995 and 2004, a total of 87 patients with Stage I NSCLC (median age, 74 years; T1N0M0, n = 65; T2N0M0, n = 22) who were medically operable but refused surgery were treated using SBRT alone in 14 institutions. Stereotactic three-dimensional treatment was performed using noncoplanar dynamic arcs or multiple static ports. Total dose was 45–72.5 Gy at the isocenter, administered in 3–10 fractions. Median calculated biological effective dose was 116 Gy (range, 100–141 Gy). Data were collected and analyzed retrospectively. Results: During follow-up (median, 55 months), cumulative local control rates for T1 and T2 tumors at 5 years after SBRT were 92% and 73%, respectively. Pulmonary complications above Grade 2 arose in 1 patient (1.1%). Five-year overall survival rates for Stage IA and IB subgroups were 72% and 62%, respectively. One patient who developed local recurrences safely underwent salvage surgery. Conclusion: Stereotactic body radiotherapy is safe and promising as a radical treatment for operable Stage I NSCLC. The survival rate for SBRT is potentially comparable to that for surgery.

  15. A Bayesian network meta-analysis of whole brain radiotherapy and stereotactic radiotherapy for brain metastasis.

    Science.gov (United States)

    Yuan, Xi; Liu, Wen-Jie; Li, Bing; Shen, Ze-Tian; Shen, Jun-Shu; Zhu, Xi-Xu

    2017-08-01

    This study was conducted to compare the effects of whole brain radiotherapy (WBRT) and stereotactic radiotherapy (SRS) in treatment of brain metastasis.A systematical retrieval in PubMed and Embase databases was performed for relative literatures on the effects of WBRT and SRS in treatment of brain metastasis. A Bayesian network meta-analysis was performed by using the ADDIS software. The effect sizes included odds ratio (OR) and 95% confidence interval (CI). A random effects model was used for the pooled analysis for all the outcome measures, including 1-year distant control rate, 1-year local control rate, 1-year survival rate, and complication. The consistency was tested by using node-splitting analysis and inconsistency standard deviation. The convergence was estimated according to the Brooks-Gelman-Rubin method.A total of 12 literatures were included in this meta-analysis. WBRT + SRS showed higher 1-year distant control rate than SRS. WBRT + SRS was better for the 1-year local control rate than WBRT. SRS and WBRT + SRS had higher 1-year survival rate than the WBRT. In addition, there was no difference in complication among the three therapies.Comprehensively, WBRT + SRS might be the choice of treatment for brain metastasis.

  16. About the case of a bronchi carcinoma tumor treated by Cyberknife

    International Nuclear Information System (INIS)

    Delourme, J.; Prevost, B.; Lacornerie, T.; Dansin, E.; Lartigau, E.

    2009-01-01

    The carcinoid tumors represent less than 2% of bronchi cancers. The best treatment of resectable tumors is surgery. The chemotherapy is inefficient. the part of radiotherapy is currently controverted, these tumors being generally considered as little radiosensitive with classical techniques. We report the case of a sixty three years patients treated by stereotactic irradiation for a recurrence of a carcinoid bronchi tumor. As conclusion: the typical or atypical character of the tumor is important to consider. The atypical carcinoid tumors have a reserved prognosis because of the frequent existence of ganglions metastases and a recurrence rate higher than the typical carcinoid tumors. The stereotactic and hypo fractionated radiotherapy can constitute an interesting therapy option in case of unresectable tumor or incomplete surgical resection, because of an increased equivalent biological dose. (N.C.)

  17. Fractionated stereotactically guided radiotherapy and radiosurgery in the treatment of functional and nonfunctional adenomas of the pituitary gland

    International Nuclear Information System (INIS)

    Milker-Zabel, Stefanie; Debus, Juergen; Thilmann, Christoph; Schlegel, Wolfgang; Wannenmacher, Michael

    2001-01-01

    Purpose: We evaluated survival rates and side effects after fractionated stereotactically guided radiotherapy (SCRT) and radiosurgery in patients with pituitary adenoma. Methods and Materials: Between 1989 and 1998, 68 patients were treated with FSRT (n=63) or radiosurgery (n=5) for pituitary adenomas. Twenty-six had functional and 42 had nonfunctional adenomas. Follow-up included CT/MRI, endocrinologic, and ophthalmologic examinations. Mean follow-up was 38.7 months. Seven patients received radiotherapy as primary treatment and 39 patients received it postoperatively for residual disease. Twenty-two patients were treated for recurrent disease after surgery. Mean total dose was 52.2 Gy for SCRT, and 15 Gy for radiosurgery. Results: Overall local tumor control was 93% (60/65 patients). Forty-three patients had stable disease based on CT/MRI, while 15 had a reduction of tumor volume. After FSRT, 26% with a functional adenoma had a complete remission and 19% had a reduction of hormonal overproduction after 34 months' mean. Two patients with STH-secreting adenomas had an endocrinologic recurrence, one with an ACTH-secreting adenoma radiologic recurrence, within 54 months. Reduction of visual acuity was seen in 4 patients and partial hypopituitarism in 3 patients. None of the patients developed brain radionecrosis or radiation-induced gliomas. Conclusion: Stereotactically guided radiotherapy is effective and safe in the treatment of pituitary adenomas to improve local control and reduce hormonal overproduction

  18. Under-reported dosimetry errors due to interplay effects during VMAT dose delivery in extreme hypofractionated stereotactic radiotherapy.

    Science.gov (United States)

    Gauer, Tobias; Sothmann, Thilo; Blanck, Oliver; Petersen, Cordula; Werner, René

    2018-06-01

    Radiotherapy of extracranial metastases changed from normofractioned 3D CRT to extreme hypofractionated stereotactic treatment using VMAT beam techniques. Random interaction between tumour motion and dynamically changing beam parameters might result in underdosage of the CTV even for an appropriately dimensioned ITV (interplay effect). This study presents a clinical scenario of extreme hypofractionated stereotactic treatment and analyses the impact of interplay effects on CTV dose coverage. For a thoracic/abdominal phantom with an integrated high-resolution detector array placed on a 4D motion platform, dual-arc treatment plans with homogenous target coverage were created using a common VMAT technique and delivered in a single fraction. CTV underdosage through interplay effects was investigated by comparing dose measurements with and without tumour motion during plan delivery. Our study agrees with previous works that pointed out insignificant interplay effects on target coverage for very regular tumour motion patterns like simple sinusoidal motion. However, we identified and illustrated scenarios that are likely to result in a clinically relevant CTV underdosage. For tumour motion with abnormal variability, target coverage quantified by the CTV area receiving more than 98% of the prescribed dose decreased to 78% compared to 100% at static dose measurement. This study is further proof of considerable influence of interplay effects on VMAT dose delivery in stereotactic radiotherapy. For selected conditions of an exemplary scenario, interplay effects and related motion-induced target underdosage primarily occurred in tumour motion pattern with increased motion variability and VMAT plan delivery using complex MLC dose modulation.

  19. Fractionated stereotactic conformal radiotherapy following conservative surgery in the control of craniopharyngiomas

    International Nuclear Information System (INIS)

    Minniti, Giuseppe; Saran, Frank; Traish, Daphne; Soomal, Rubin; Sardell, Susan; Gonsalves, Adam; Ashley, Susan; Warrington, Jim; Burke, Kevin; Mosleh-Shirazi, Amin; Brada, Michael

    2007-01-01

    Purpose: To describe the technique and results of stereotactically guided conformal radiotherapy (SCRT) in patients with craniopharyngioma after conservative surgery. Methods and materials: Thirty-nine patients with craniopharyngioma aged 3-68 years (median age 18 years) were treated with SCRT between June 1994 and January 2003. All patients were referred for radiotherapy after undergoing one or more surgical procedures. Treatment was delivered in 30-33 daily fractions over 6-6.5 weeks to a total dose of 50 Gy using 6 MV photons. Outcome was assessed prospectively. Results: At a median follow-up of 40 months (range 3-88 months) the 3- and 5-year progression-free survival (PFS) was 97% and 92%, and 3- and 5-year survival 100%. Two patients required further debulking surgery for progressive disease 8 and 41 months after radiotherapy. Twelve patients (30%) had acute clinical deterioration due to cystic enlargement of craniopharyngioma following SCRT and required cyst aspiration. One patient with severe visual impairment prior to radiotherapy had visual deterioration following SCRT. Seven out of 10 patients with a normal pituitary function before SCRT had no endocrine deficits following treatment. Conclusion: SCRT as a high-precision technique of localized RT is suitable for the treatment of incompletely excised craniopharyngioma. The local control, toxicity and survival outcomes are comparable to results reported following conventional external beam RT. Longer follow-up is required to assess long-term efficacy and toxicity, particularly in terms of potential reduction in treatment related late toxicity

  20. An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration

    International Nuclear Information System (INIS)

    Seo, Jung Min; Lee, Chang Yeol; Huh, Hyun Do; Kim, Wan Sun

    2015-01-01

    Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. If the target

  1. An accuracy analysis of Cyberknife tumor tracking radiotherapy according to unpredictable change of respiration

    Energy Technology Data Exchange (ETDEWEB)

    Seo, Jung Min; Lee, Chang Yeol; Huh, Hyun Do; Kim, Wan Sun [Dept. of Radiation Oncology, Inha university hospital, Incheon (Korea, Republic of)

    2015-12-15

    Cyber-Knife tumor tracking system, based on the correlation relationship between the position of a tumor which moves in response to the real time respiratory cycle signal and respiration was obtained by the LED marker attached to the outside of the patient, the location of the tumor to predict in advance, the movement of the tumor in synchronization with the therapeutic device to track real-time tumor, is a system for treating. The purpose of this study, in the cyber knife tumor tracking radiation therapy, trying to evaluate the accuracy of tumor tracking radiation therapy system due to the change in the form of unpredictable sudden breathing due to cough and sleep. Materials and Methods : Breathing Log files that were used in the study, based on the Respiratory gating radiotherapy and Cyber-knife tracking radiosurgery breathing Log files of patients who received herein, measured using the Log files in the form of a Sinusoidal pattern and Sudden change pattern. it has been reconstituted as possible. Enter the reconstructed respiratory Log file cyber knife dynamic chest Phantom, so that it is possible to implement a motion due to respiration, add manufacturing the driving apparatus of the existing dynamic chest Phantom, Phantom the form of respiration we have developed a program that can be applied to. Movement of the phantom inside the target (Ball cube target) was driven by the displacement of three sizes of according to the size of the respiratory vertical (Superior-Inferior) direction to the 5 mm, 10 mm, 20 mm. Insert crosses two EBT3 films in phantom inside the target in response to changes in the target movement, the End-to-End (E2E) test provided in Cyber-Knife manufacturer depending on the form of the breathing five times each. It was determined by carrying. Accuracy of tumor tracking system is indicated by the target error by analyzing the inserted film, additional E2E test is analyzed by measuring the correlation error while being advanced. If the target

  2. Stereotactic ablative radiotherapy versus lobectomy for operable stage I non-small-cell lung cancer : a pooled analysis of two randomised trials

    NARCIS (Netherlands)

    Chang, Joe Y.; Senan, Suresh; Paul, Marinus A.; Mehran, Reza J.; Louie, Alexander V.; Balter, Peter; Groen, Harry; McRae, Stephen E.; Widder, Joachim; Feng, Lei; van den Borne, Ben E. E. M.; Munsell, Mark F.; Hurkmans, Coen; Berry, Donald A.; van Werkhoven, Erik; Kresl, John J.; Dingemans, Anne-Marie; Dawood, Omar; Haasbeek, Cornelis J. A.; Carpenter, Larry S.; De Jaeger, Katrien; Komaki, Ritsuko; Slotman, Ben J.; Smit, Egbert F.; Roth, Jack A.

    Background The standard of care for operable, stage I, non-small-cell lung cancer (NSCLC) is lobectomy with mediastinal lymph node dissection or sampling. Stereotactic ablative radiotherapy (SABR) for inoperable stage I NSCLC has shown promising results, but two independent, randomised, phase 3

  3. Stereotactic body radiotherapy: a promising treatment option for the boost of oropharyngeal cancers not suitable for brachytherapy: a single-institutional experience.

    NARCIS (Netherlands)

    Al-Mamgani, A.; Tans, L.; Teguh, D.N.; Rooij, P. van; Zwijnenburg, E.M.; Levendag, P.C.

    2012-01-01

    PURPOSE: To prospectively assess the outcome and toxicity of frameless stereotactic body radiotherapy (SBRT) as a treatment option for boosting primary oropharyngeal cancers (OPC) in patients who not suitable for the standard brachytherapy boost (BTB). METHODS AND MATERIALS: Between 2005 and 2010,

  4. SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

    International Nuclear Information System (INIS)

    Sanli, E; Mabhouti, H; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H

    2016-01-01

    Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose

  5. SU-F-SPS-10: The Dosimetric Comparison of GammaKnife and Cyberknife Treatment Plans for Brain SRS Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Sanli, E; Mabhouti, H; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: Brain stereotactic radiosurgery (SRS) involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of GammaKnife perfection and Cyberknife M6 treatment plans were made. Methods: Treatment plannings were done for GammaKnife perfection unit using Gammaplan treatment planning system (TPS) on the CT scan of head and neck randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using TMR 10 algorithm. The treatment planning for the same target were also done for Cyberknife M6 machine using Multiplan (TPS) with Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife treatment plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For gammaknife treatment plans, the gamma analysis passing rates were 98.9% and 93.2% for target and peripheral region of target respectively. Conclusion: The study shows that dosimetrically comparable plans are achievable with Cyberknife and GammaKnife. Although TMR 10 algorithm predicts the target dose.

  6. Comparison of static conformal field with multiple noncoplanar arc techniques for stereotactic radiosurgery or stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Hamilton, Russell J.; Kuchnir, Franca T.; Sweeney, Patrick; Rubin, Steven J.; Dujovny, Manuel; Pelizzari, Charles A.; Chen, George T. Y.

    1995-01-01

    Purpose: Compare the use of static conformal fields with the use of multiple noncoplanar arcs for stereotactic radiosurgery or stereotactic radiotherapy treatment of intracranial lesions. Evaluate the efficacy of these treatment techniques to deliver dose distributions comparable to those considered acceptable in current radiotherapy practice. Methods and Materials: A previously treated radiosurgery case of a patient presenting with an irregularly shaped intracranial lesion was selected. Using a three-dimensional (3D) treatment-planning system, treatment plans using a single isocenter multiple noncoplanar arc technique and multiple noncoplanar conformal static fields were generated. Isodose distributions and dose volume histograms (DVHs) were computed for each treatment plan. We required that the 80% (of maximum dose) isodose surface enclose the target volume for all treatment plans. The prescription isodose was set equal to the minimum target isodose. The DVHs were analyzed to evaluate and compare the different treatment plans. Results: The dose distribution in the target volume becomes more uniform as the number of conformal fields increases. The volume of normal tissue receiving low doses (> 10% of prescription isodose) increases as the number of static fields increases. The single isocenter multiple arc plan treats the greatest volume of normal tissue to low doses, approximately 1.6 times more volume than that treated by four static fields. The volume of normal tissue receiving high (> 90% of prescription isodose) and intermediate (> 50% of prescription isodose) doses decreases by 29 and 22%, respectively, as the number of static fields is increased from four to eight. Increasing the number of static fields to 12 only further reduces the high and intermediate dose volumes by 10 and 6%, respectively. The volume receiving the prescription dose is more than 3.5 times larger than the target volume for all treatment plans. Conclusions: Use of a multiple noncoplanar

  7. Stereotactic body radiation therapy (SBRT) in the treatment of liver metastases: State of the art; Radiotherapie en conditions stereotaxiques des metastases hepatiques

    Energy Technology Data Exchange (ETDEWEB)

    De Bari, B.; Guillet, M.; Mornex, F. [Departement de radiotherapie oncologie, centre hospitalier Lyon-Sud, chemin du Grand-Revoyet, 69310 Pierre-Benite (France); EA3738, domaine Rockefeller, universite Claude-Bernard, 8, avenue Rockefeller, 69373 Lyon cedex 08 (France)

    2011-02-15

    Liver metastases are frequently found in oncologic patients. Chemotherapy is the standard treatment in pluri-metastatic patients, with the possibility to obtain a clear improvement of their prognosis. Local treatment (surgery, radiofrequency, cryo-therapy, radiotherapy, etc.) could be proposed for oligo-metastatic patients, particularly for those with a good prognosis. Historically, radiation therapy has had a limited role in the treatment of liver metastases because of its toxicity when whole liver irradiation was delivered. Improvements in the knowledge of liver radiobiology and radio-pathology as well as technical innovations in delivering radiation therapy are the basis of the modern partial liver irradiation concept. In this historical and therapeutic landscape, extracranial stereotactic radiation therapy is particularly interesting for the treatment of liver metastases. This review summarises published data on stereotactic radiotherapy for the treatment of liver metastases. (authors)

  8. Initial results of CyberKnife treatment for recurrent previously irradiated head and neck cancer

    International Nuclear Information System (INIS)

    Himei, Kengo; Katsui, Kuniaki; Yoshida, Atsushi

    2003-01-01

    The purpose of this study was to evaluate the efficacy of CyberKnife for recurrent previously irradiated head and neck cancer. Thirty-one patients with recurrent previously irradiated head and neck cancer were treated with a CyberKnife from July 1999 to March 2002 at Okayama Kyokuto Hospital were retrospectively studied. The accumulated dose was 28-80 Gy (median 60 Gy). The interval between CyberKnife treatment and previous radiotherapy was 0.4-429.5 months (median 16.3 months). Primary lesions were nasopharynx: 7, maxillary sinus: 6, tongue: 5, ethmoid sinus: 3, and others: 1. The pathology was squamous cell carcinoma: 25, adenoid cystic carcinoma: 4, and others: 2. Symptoms were pain: 8, and nasal bleeding: 2. The prescribed dose was 15.0-40.3 Gy (median 32.3 Gy) as for the marginal dose. The response rate (complete response (CR)+partial response (PR)) and local control rate (CR+PR+no change (NC)) was 74% and 94% respectively. Pain disappeared for 4 cases, relief was obtained for 4 cases and no change for 2 cases and nasal bleeding disappeared for 2 cases for an improvement of symptoms. An adverse effects were observed as mucositis in 5 cases and neck swelling in one case. Prognosis of recurrent previously irradiated head and neck cancer was estimated as poor. Our early experience shows that CyberKnife is expected to be feasible treatment for recurrent previously irradiated head and neck cancer, and for the reduction adverse effects and maintenance of useful quality of life (QOL) for patients. (author)

  9. Long term results after fractionated stereotactic radiotherapy (FSRT) in patients with craniopharyngioma: maximal tumor control with minimal side effects.

    Science.gov (United States)

    Harrabi, Semi B; Adeberg, Sebastian; Welzel, Thomas; Rieken, Stefan; Habermehl, Daniel; Debus, Jürgen; Combs, Stephanie E

    2014-09-16

    There are already numerous reports about high local control rates in patients with craniopharyngioma but there are only few studies with follow up times of more than 10 years. This study is an analysis of long term control, tumor response and side effects after fractionated stereotactic radiotherapy (FSRT) for patients with craniopharyngioma. 55 patients who were treated with FSRT for craniopharyngioma were analyzed. Median age was 37 years (range 6-70 years), among them eight children craniopharyngioma. Overall treatment was tolerated well with almost no severe acute or chronic side effects. One patient developed complete anosmia, another one's initially impaired vision deteriorated further. In 83.6% of the cases with radiological follow up a regression of irradiated tumor residues was monitored, in 7 cases complete response was achieved. 44 patients presented themselves initially with endocrinologic dysfunction none of them showed signs of further deterioration during follow up. No secondary malignancies were observed. Long term results for patients with craniopharyngioma after stereotactic radiotherapy are with respect to low treatment related side effects as well as to local control and overall survival excellent.

  10. Extracranial stereotactic radiotherapy for primary and metastatic renal cell carcinoma

    International Nuclear Information System (INIS)

    Wersaell, Peter J.; Blomgren, Henric; Lax, Ingmar; Kaelkner, Karl-Mikael; Linder, Christina; Lundell, Goeran; Nilsson, Bo; Nilsson, Sten; Naeslund, Ingemar; Pisa, Pavel; Svedman, Christer

    2005-01-01

    Background and purpose: We investigated the results of using stereotactic radiotherapy (SRT) for 58 patients with renal cell carcinomas (RCC) who were evaluated restrospectively for response rates, local control rates and side effects. Patients and methods: From October 1997 to January 2003, 50 patients suffering from metastatic RCC and eight patients with inoperable primary RCC received high-dose fraction SRT while placed in a stereotactic body-frame. The most common dose/fractionation schedules used were 8 Gyx4, 10 Gyx4 and 15 Gyx3 during approximately 1 week. Results: SRT-treated tumor lesions regressed totally in 30% of the patients at 3-36 months, whereas 60% of the patients had a partial volume reduction or no change after a median follow-up of 37 months (SD 17.4) for censored and 13 months (SD 12.9) for uncensored patients. Side effects were generally mild. Of 162 treated tumors, only three recurred, yielding a local control rate of 90-98%, considering the 8% non-evaluable sites as defined here. For patients with one to three metastases, the time to new spread was 9 months. Conclusions: Our use of SRT for patients with primary and metastatic RCC yielded a high local control rate with low toxicity. Patients with one to three metastases, local recurrences after nephrectomy or inoperable primary tumors benefited the most, i.e. had fewer distant recurrences (13/23) and longer survival times compared to patients with >3 metastases (24/27 recurrences)

  11. Poster — Thur Eve — 23: Dose and Position Quality Assurance using the RADPOS System for 4D Radiotherapy with CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Marants, R [Department of Medical Physics, Carleton University (Canada); Vandervoort, E [Department of Medical Physics, The Ottawa Hospital Cancer Centre (Canada); Cygler, J E [Department of Medical Physics, Carleton University, Department of Medical Physics, The Ottawa Hospital Cancer Centre (Canada)

    2014-08-15

    Introduction: RADPOS 4D dosimetry system consists of a microMOSFET dosimeter combined with an electromagnetic positioning sensor, which allows for performing real-time dose and position measurements simultaneously. In this report the use of RADPOS as an independent quality assurance (QA) tool during CyberKnife 4D radiotherapy treatment is described. In addition to RADPOS, GAFCHROMIC® films were used for simultaneous dose measurement. Methods: RADPOS and films were calibrated in a Solid Water® phantom at 1.5 cm depth, SAD= 80 cm, using 60 mm cone. CT based treatment plan was created for a Solid Water® breast phantom containing metal fiducials and RADPOS probe. Dose calculations were performed using iPlan pencil beam algorithm. Before the treatment delivery, GAFCHROMIC® film was inserted inside the breast phantom, next to the RADPOS probe. Then the phantom was positioned on the chest platform of the QUASAR, to which Synchrony LED optical markers were also attached. Position logging began for RADPOS and the Synchrony tracking system, the QUASAR motion was initiated and the treatment was delivered. Results: RADPOS position measurements very closely matched the LED marker positions recorded by the Synchrony camera tracking system. The RADPOS measured dose was 2.5% higher than the average film measured dose, which is within the experimental uncertainties. Treatment plan calculated dose was 4.1 and 1.6% lower than measured by RADPOS and film, respectively. This is most likely due to the inferior nature of the dose calculation algorithm. Conclusions: Our study demonstrates that RADPOS system is a useful tool for independent QA of CyberKnife treatments.

  12. Stereotactic Body Radiotherapy for Localized Ureter Transitional Cell Carcinoma: Three Case Reports

    Directory of Open Access Journals (Sweden)

    Yoshiyasu Maehata

    2015-01-01

    Full Text Available The gold standard management for ureter transitional cell carcinoma (UTCC is radical nephroureterectomy with excision of the bladder cuff. However, some patients cannot undergo this procedure for several reasons. In the case reports described herein, we performed stereotactic body radiotherapy (SBRT on three patients with inoperable or surgery-rejected localized UTCC. Two out of the three patients did not develop local recurrence or distant metastasis during the observation period. However, recurrence was detected in the bladder of one patient 22 months after the treatment. No acute or late adverse events occurred in any of the three patients. SBRT may become one of the treatment options for inoperable or surgery-rejected UTCC patients.

  13. SU-E-T-282: Dose Measurements with An End-To-End Audit Phantom for Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Jones, R; Artschan, R [Calvary Mater Newcastle, Newcastle, NSW (Australia); Thwaites, D [University of Sydney, Sydney, NSW (Australia); Lehmann, J [Calvary Mater Newcastle, Newcastle, NSW (Australia); University of Sydney, Sydney, NSW (Australia)

    2015-06-15

    Purpose: Report on dose measurements as part of an end-to-end test for stereotactic radiotherapy, using a new audit tool, which allows audits to be performed efficiently either by an onsite team or as a postal audit. Methods: Film measurements have been performed with a new Stereotactic Cube Phantom. The phantom has been designed to perform Winston Lutz type position verification measurements and dose measurements in one setup. It comprises a plastic cube with a high density ball in its centre (used for MV imaging with film or EPID) and low density markers in the periphery (used for Cone Beam Computed Tomography, CBCT imaging). It also features strategically placed gold markers near the posterior and right surfaces, which can be used to calculate phantom rotations on MV images. Slit-like openings allow insertion of film or other detectors.The phantom was scanned and small field treatment plans were created. The fields do not traverse any inhomogeneities of the phantom on their paths to the measurement location. The phantom was setup at the delivery system using CBCT imaging. The calculated treatment fields were delivered, each with a piece of radiochromic film (EBT3) placed in the anterior film holder of the phantom. MU had been selected in planning to achieve similar exposures on all films. Calibration films were exposed in solid water for dose levels around the expected doses. Films were scanned and analysed following established procedures. Results: Setup of the cube showed excellent suitability for CBCT 3D alignment. MV imaging with EPID allowed for clear identification of all markers. Film based dose measurements showed good agreement for MLC created fields down to 0.5 mm × 0.5 mm. Conclusion: An end-to-end audit phantom for stereotactic radiotherapy has been developed and tested.

  14. The accuracy of dose calculations by anisotropic analytical algorithms for stereotactic radiotherapy in nasopharyngeal carcinoma

    International Nuclear Information System (INIS)

    Kan, M W K; Cheung, J Y C; Leung, L H T; Lau, B M F; Yu, P K N

    2011-01-01

    Nasopharyngeal tumors are commonly treated with intensity-modulated radiotherapy techniques. For photon dose calculations, problems related to loss of lateral electronic equilibrium exist when small fields are used. The anisotropic analytical algorithm (AAA) implemented in Varian Eclipse was developed to replace the pencil beam convolution (PBC) algorithm for more accurate dose prediction in an inhomogeneous medium. The purpose of this study was to investigate the accuracy of the AAA for predicting interface doses for intensity-modulated stereotactic radiotherapy boost of nasopharyngeal tumors. The central axis depth dose data and dose profiles of phantoms with rectangular air cavities for small fields were measured using a 6 MV beam. In addition, the air-tissue interface doses from six different intensity-modulated stereotactic radiotherapy plans were measured in an anthropomorphic phantom. The nasopharyngeal region of the phantom was especially modified to simulate the air cavities of a typical patient. The measured data were compared to the data calculated by both the AAA and the PBC algorithm. When using single small fields in rectangular air cavity phantoms, both AAA and PBC overestimated the central axis dose at and beyond the first few millimeters of the air-water interface. Although the AAA performs better than the PBC algorithm, its calculated interface dose could still be more than three times that of the measured dose when a 2 x 2 cm 2 field was used. Testing of the algorithms using the anthropomorphic phantom showed that the maximum overestimation by the PBC algorithm was 20.7%, while that by the AAA was 8.3%. When multiple fields were used in a patient geometry, the dose prediction errors of the AAA would be substantially reduced compared with those from a single field. However, overestimation of more than 3% could still be found at some points at the air-tissue interface.

  15. Enable dosimetric of the Stereotactic Body Frame from Elekta in treatment planning systems for Radiotherapy

    International Nuclear Information System (INIS)

    Gonzalez Perez, Y.; Caballero Pinelo, R.; Alfonso Laguardia, R.

    2015-01-01

    The purpose of this study is to evaluate the commissioning of a stereotactic body frame (SBF ® , Elekta) professional treatment planning systems (TPS) model Elekta's PrecisePlan ® and ERGO++®, for highly foxused delivery of megavoltage photon beams intended for treating tumors located in the thorax and abdominal region. For this purpose we applicated a dedicate stereotactic body frame (SBF ® , Elekta) intended for high precision radiotherapy in extra-cranial located tumors was studied. Issues associated with their implementation in the TPSs were evaluated comparing the dose calculations in two studies of CT under different conditions. an anthropomorphic thorax phantom, model CIRS Thorax IMRT ® , was used in designing several test cases. Ion chamber measurement was permormed in selected points in the phantom, for comparison purposes with dose calculated by the treatment planning systems. The commissioning of the stereotactic body frame (SBF ® , Elekta) and the stereotactic localization was verified, including the dose calculation verification in presence the SBF. The attenuation factors measured for the SBF were obtained and corrected in the TPS PrecisePlan ® , the biggest discrepancies obtained were ∼5% for the oblique sectors (inferior corners), because the minimum permissible value for the software is 0.95 while the real value measured was 0.898. It was studied the SBF, their components and their interference in depth with the photon beams and their implementation in the TPS. The introduction of the correction factors demonstrated to be effective to reduce the eventual errors of dose calculation in the TPS . (Author)

  16. Progression-free Survival Following Stereotactic Body Radiotherapy for Oligometastatic Prostate Cancer Treatment-naive Recurrence: A Multi-institutional Analysis.

    Science.gov (United States)

    Ost, Piet; Jereczek-Fossa, Barbara Alicja; As, Nicholas Van; Zilli, Thomas; Muacevic, Alexander; Olivier, Kenneth; Henderson, Daniel; Casamassima, Franco; Orecchia, Roberto; Surgo, Alessia; Brown, Lindsay; Tree, Alison; Miralbell, Raymond; De Meerleer, Gert

    2016-01-01

    The literature on metastasis-directed therapy for oligometastatic prostate cancer (PCa) recurrence consists of small heterogeneous studies. This study aimed to reduce the heterogeneity by pooling individual patient data from different institutions treating oligometastatic PCa recurrence with stereotactic body radiotherapy (SBRT). We focussed on patients who were treatment naive, with the aim of determining if SBRT could delay disease progression. We included patients with three or fewer metastases. The Kaplan-Meier method was used to estimate distant progression-free survival (DPFS) and local progression-free survival (LPFS). Toxicity was scored using the Common Terminology Criteria for Adverse Events. In total, 163 metastases were treated in 119 patients. The median DPFS was 21 mo (95% confidence interval, 15-26 mo). A lower radiotherapy dose predicted a higher local recurrence rate with a 3-yr LPFS of 79% for patients treated with a biologically effective dose ≤100Gy versus 99% for patients treated with >100Gy (p=0.01). Seventeen patients (14%) developed toxicity classified as grade 1, and three patients (3%) developed grade 2 toxicity. No grade ≥3 toxicity occurred. These results should serve as a benchmark for future prospective trials. This multi-institutional study pools all of the available data on the use of stereotactic body radiotherapy for limited prostate cancer metastases. We concluded that this approach is safe and associated with a prolonged treatment progression-free survival. Copyright © 2015. Published by Elsevier B.V.

  17. Long-Term Outcomes of Vestibular Schwannomas Treated With Fractionated Stereotactic Radiotherapy: An Institutional Experience

    International Nuclear Information System (INIS)

    Kapoor, Sumit; Batra, Sachin; Carson, Kathryn; Shuck, John; Kharkar, Siddharth; Gandhi, Rahul; Jackson, Juan; Wemmer, Jan; Terezakis, Stephanie; Shokek, Ori; Kleinberg, Lawrence; Rigamonti, Daniele

    2011-01-01

    Purpose: We assessed clinical outcome and long-term tumor control after fractionated stereotactic radiotherapy (FSRT) for unilateral schwannoma. Methods and Materials: Between 1995 and 2007, 496 patients were treated with fractionated stereotactic radiotherapy at Johns Hopkins Hospital (Baltimore, MD); 385 patients had radiologic follow-up that met the inclusion criteria. The primary endpoint was treatment failure. Secondary endpoints were radiologic progression and clinical outcome. Logistic regression analysis assessed the association of age, race, tumor side, sex, and pretreatment symptoms. Results: In 11 patients (3%) treatment failed, and they required salvage (microsurgical) treatment. Radiologic progression was observed in 116 patients (30.0%), including 35 patients (9%) in whom the treatment volume more than doubled during the follow-up period, although none required surgical resection. Tumors with baseline volumes of less than 1 cm 3 were 18.02 times more likely to progress than those with tumor volumes of 1 cm 3 or greater (odds ratio, 18.02; 95% confidence interval, 4.25-76.32). Treatment-induced neurologic morbidity included 8 patients (1.6%) with new facial weakness, 12 patients (2.8%) with new trigeminal paresthesias, 4 patients (0.9%) with hydrocephalus (1 communicating and 3 obstructive), and 2 patients (0.5%) with possibly radiation-induced neoplasia. Conclusions: Although the rate of treatment failure is low (3%), careful follow-up shows that radiologic progression occurs frequently. When reporting outcome, the 'no salvage surgery needed' and 'no additional treatment needed' criteria for treatment success need to be complemented by the radiologic data.

  18. Definition of stereotactic body radiotherapy. Principles and practice for the treatment of stage I non-small cell lung cancer

    Energy Technology Data Exchange (ETDEWEB)

    Guckenberger, M.; Sauer, O. [University of Wuerzburg, Department of Radiation Oncology, Wuerzburg (Germany); Andratschke, N. [University of Rostock, Department of Radiotherapy and Radiation Oncology, Rostock (Germany); Alheit, H. [Distler Radiation Oncology, Bautzen/Pirna (Germany); Holy, R. [RWTH Aachen University, Department of Radiation Oncology, Aachen (Germany); Moustakis, C. [University of Muenster, Department of Radiation Oncology, Muenster (Germany); Nestle, U. [University of Freiburg, Department of Radiation Oncology, Freiburg (Germany)

    2014-01-15

    This report from the Stereotactic Radiotherapy Working Group of the German Society of Radiation Oncology (Deutschen Gesellschaft fuer Radioonkologie, DEGRO) provides a definition of stereotactic body radiotherapy (SBRT) that agrees with that of other international societies. SBRT is defined as a method of external beam radiotherapy (EBRT) that accurately delivers a high irradiation dose to an extracranial target in one or few treatment fractions. Detailed recommendations concerning the principles and practice of SBRT for early stage non-small cell lung cancer (NSCLC) are given. These cover the entire treatment process; from patient selection, staging, treatment planning and delivery to follow-up. SBRT was identified as the method of choice when compared to best supportive care (BSC), conventionally fractionated radiotherapy and radiofrequency ablation. Based on current evidence, SBRT appears to be on a par with sublobar resection and is an effective treatment option in operable patients who refuse lobectomy. (orig.) [German] Die Arbeitsgruppe ''Stereotaktische Radiotherapie'' der Deutschen Gesellschaft fuer Radioonkologie (DEGRO) erarbeitete eine Definition der Koerperstereotaxie (SBRT), die sich an vorhandene internationale Definitionen anlehnt: Die SBRT ist eine Form der perkutanen Strahlentherapie, die mit hoher Praezision eine hohe Bestrahlungsdosis in einer oder wenigen Bestrahlungsfraktionen in einem extrakraniellen Zielvolumen appliziert. Zur Praxis der SBRT beim nichtkleinzelligen Bronchialkarzinom (NSCLC) im fruehen Stadium werden detaillierte Empfehlungen gegeben, die den gesamten Ablauf der Behandlung von der Indikationsstellung, Staging, Behandlungsplanung und Applikation sowie Nachsorge umfassen. Die Koerperstereotaxie wurde als Methode der Wahl im Vergleich zu Best Supportive Care, zur konventionell fraktionierten Strahlentherapie sowie zur Radiofrequenzablation identifiziert. Die Ergebnisse nach SBRT und sublobaerer Resektion

  19. Translational and rotational intra- and inter-fractional errors in patient and target position during a short course of frameless stereotactic body radiotherapy

    DEFF Research Database (Denmark)

    Josipovic, Mirjana; Persson, Gitte Fredberg; Logadottir, Ashildur

    2012-01-01

    Implementation of cone beam computed tomography (CBCT) in frameless stereotactic body radiotherapy (SBRT) of lung tumours enables setup correction based on tumour position. The aim of this study was to compare setup accuracy with daily soft tissue matching to bony anatomy matching and evaluate...

  20. A verification methodology for in vivo dosimetry in stereotactic radiotherapy; Uma metodologia para verificacao dosimetrica in vivo em radioterapia estereotaxica

    Energy Technology Data Exchange (ETDEWEB)

    Amaral, Leonardo L.; Oliveira, Harley F.; Fairbanks, Leandro R., E-mail: leonardo.fis@usp.br [Universidade de Sao Paulo (HCFMRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina. Hospital das Clinicas; Nicolucci, Patricia; Netto, Thomaz G. [Universidade de Sao Paulo (FFCLRP/USP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras. Departamento de Fisica

    2012-12-15

    Radiotherapy of brain lesions near critical structures requires a high accuracy in the location and dose. The high precision is achieved by the location of the stereotactic apparatus. The accuracy in dose delivery should be accompanied by an accurate quality control in devices that involve the practice, however, still does not guarantee the dose at the time of therapy. The large number of fields and the small size of these conventional methods difficult dosimetry during treatment. The objective of this work was to develop a verification methodology in vivo dosimetry in stereotactic radiotherapy with the aid of the film radiochromic Linear Accelerator with multi leaf collimators Moduleaf. The technique uses film segments radiochromic Gafchromic EBT2, with dimensions of 1x1 cm{sup 2} in area outside the coupled micro-multileaf Moduleaf Siemens. These films were inserted in the region of the central axis of the beam. The films were irradiated and calibrated to obtain the factors that determine the size dependence of the dosimetric field. With these data, we designed a computer program which calculates the density of a film must acquire when subjected to an exposure in this setting. This study evaluated five non-coplanar plans, the first with 15 fields and the other with 25 fields. Before starting the procedure, the film segment is coupled to the device, and after the treatment, the relative density is evaluated and compared with the calculated. The average value of the verification at the time of radiation dosimetry compared with the calculated by the sheet was 1.5%. The data collected in this study showed a satisfactory agreement between measured and calculated by the program in the densitometer. Thus, a methodology was developed to verify in vivo dosimetry in radiotherapy and stereotactic linear accelerator collimators Moduleaf. (author)

  1. [Transient enlargement of craniopharyngioma cysts after stereotactic radiotherapy and radiosurgery].

    Science.gov (United States)

    Mazerkina, N A; Savateev, A N; Gorelyshev, S K; Konovalov, A N; Trunin, Yu Yu; Golanov, A V; Medvedeva, O A; Kalinin, P L; Kutin, M A; Astafieva, L I; Krasnova, T S; Ozerova, V I; Serova, N K; Butenko, E I; Strunina, Yu V

    Stereotactic radiotherapy/radiosurgery (RT/ES) is an effective technique for treating craniopharyngiomas (CPs). However, enlargement of the cystic part of the tumor occurs in some cases after irradiation. The enlargement may be transient and not require treatment or be a true relapse requiring treatment. In this study, we performed a retrospective analysis of 79 pediatric patients who underwent stereotactic RT or RS after resection of craniopharyngioma. Five-year relapse-free survival after complex treatment of CP was 86%. In the early period after irradiation, 3.5 months (2.7-9.4) on average, enlargement of the cystic component of the tumor was detected in 10 (12.7%) patients; in 9 (11.4%) of them, the enlargement was transient and did not require treatment; in one case, the patient underwent surgery due to reduced visual acuity. In 8 (10.1%) patients, an increase in the residual tumor (a solid component of the tumor in 2 cases and a cystic component of the tumor in 6 cases) occurred in the long-term period after irradiation - after 26.3 months (16.6-48.9) and did not decrease during follow-up in none of the cases, i.e. continued growth of the tumor was diagnosed. A statistical analysis revealed that differences in the terms of transient enlargement and true continued growth were statistically significant (pcraniopharyngioma cyst in the early period (up to 1 year) after RT/RS is usually transient and does not require surgical treatment (except cases where worsening of neurological symptoms occurs, or occlusive hydrocephalus develops).

  2. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    Energy Technology Data Exchange (ETDEWEB)

    Yazici, Gozde [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Kiratli, Hayyam [Department of Ophthalmology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Tarlan, Bercin [Bascom Palmer Eye Institute, Miami, Florida (United States); Mocan, Burce Ozgen [Department of Radiology, Faculty of Medicine, Hacettepe University, Ankara (Turkey); Zorlu, Faruk, E-mail: fzorlu@hacettepe.edu.tr [Department of Radiation Oncology, Faculty of Medicine, Hacettepe University, Ankara (Turkey)

    2017-05-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  3. Stereotactic Radiosurgery and Fractionated Stereotactic Radiation Therapy for the Treatment of Uveal Melanoma

    International Nuclear Information System (INIS)

    Yazici, Gozde; Kiratli, Hayyam; Ozyigit, Gokhan; Sari, Sezin Yuce; Cengiz, Mustafa; Tarlan, Bercin; Mocan, Burce Ozgen; Zorlu, Faruk

    2017-01-01

    Purpose: To evaluate treatment results of stereotactic radiosurgery or fractionated stereotactic radiation therapy (SRS/FSRT) for uveal melanoma. Methods and Materials: We retrospectively evaluated 181 patients with 182 uveal melanomas receiving SRS/FSRT between 2007 and 2013. Treatment was administered with CyberKnife. Results: According to Collaborative Ocular Melanoma Study criteria, tumor size was small in 1%, medium in 49.5%, and large in 49.5% of the patients. Seventy-one tumors received <45 Gy, and 111 received ≥45 Gy. Median follow-up time was 24 months. Complete and partial response was observed in 8 and 104 eyes, respectively. The rate of 5-year overall survival was 98%, disease-free survival 57%, local recurrence-free survival 73%, distant metastasis-free survival 69%, and enucleation-free survival 73%. There was a significant correlation between tumor size and disease-free survival, SRS/FSRT dose and enucleation-free survival; and both were prognostic for local recurrence-free survival. Enucleation was performed in 41 eyes owing to progression in 26 and complications in 11. Conclusions: The radiation therapy dose is of great importance for local control and eye retention; the best treatment outcome was achieved using ≥45 Gy in 3 fractions.

  4. 3D quantitative assessment of response to fractionated stereotactic radiotherapy and single-session stereotactic radiosurgery of vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Schneider, T. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States); University Medical Center Hamburg-Eppendorf, Department of Diagnostic and Interventional Neuroradiology, Hamburg (Germany); Chapiro, J. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Lin, M. [Philips Research North America, Ultrasound Imaging and Interventions (UII), Briarcliff Manor, NY (United States); Geschwind, J.F. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Interventional Radiology, Baltimore, MD (United States); Yale University School of Medicine, Department of Radiology and Imaging Science, New Haven, CT (United States); Kleinberg, L. [The Johns Hopkins University School of Medicine, Department of Radiation Oncology and Molecular Radiation Sciences, Sidney Kimmel Comprehensive Cancer Center, Baltimore, MD (United States); Rigamonti, D.; Jusue-Torres, I.; Marciscano, A.E. [The Johns Hopkins University School of Medicine, Department of Neurological Surgery, Baltimore, MD (United States); Yousem, D.M. [The Johns Hopkins Hospital School of Medicine, Russell H. Morgan Department of Radiology and Radiological Sciences, Division of Neuroradiology, Baltimore, MD (United States)

    2016-03-15

    To determine clinical outcome of patients with vestibular schwannoma (VS) after treatment with fractionated stereotactic radiotherapy (FSRT) and single-session stereotactic radiosurgery (SRS) by using 3D quantitative response assessment on MRI. This retrospective analysis included 162 patients who underwent radiation therapy for sporadic VS. Measurements on T1-weighted contrast-enhanced MRI (in 2-year post-therapy intervals: 0-2, 2-4, 4-6, 6-8, 8-10, 10-12 years) were taken for total tumour volume (TTV) and enhancing tumour volume (ETV) based on a semi-automated technique. Patients were considered non-responders (NRs) if they required subsequent microsurgical resection or developed radiological progression and tumour-related symptoms. Median follow-up was 4.1 years (range: 0.4-12.0). TTV and ETV decreased for both the FSRT and SRS groups. However, only the FSRT group achieved significant tumour shrinkage (p < 0.015 for TTV, p < 0.005 for ETV over time). The 11 NRs showed proportionally greater TTV (median TTV pre-treatment: 0.61 cm{sup 3}, 8-10 years after: 1.77 cm{sup 3}) and ETV despite radiation therapy compared to responders (median TTV pre-treatment: 1.06 cm{sup 3}; 10-12 years after: 0.81 cm{sup 3}; p = 0.001). 3D quantification of VS showed a significant decrease in TTV and ETV on FSRT-treated patients only. NR had significantly greater TTV and ETV over time. (orig.)

  5. Treat high cervical spinal arteriovenous malformation with Cyberknife radiosurgery

    Directory of Open Access Journals (Sweden)

    Yu-Fen Huang

    2014-01-01

    Full Text Available This paper describes the use of CyberKnife radiosurgery in the treatment of accidentally found cervical spinal arteriovenous malformation (AVM. We present the case of a patient with cervical spinal AVM, who developed progressive neck pain, gait disturbance, urine and stool incontinence 2 weeks after the fell down accident. The patient underwent CyberKnife radiosurgery. After CyberKnife radiosurgery for 2 years, the patient′s neck pain diminished and was able to keep the walk without any assistance. The management of cervical spinal AVM varies. This patient demonstrated a successful treatment of cervical spinal AVM with CyberKnife radiosurgery.

  6. Stereotactic body radiotherapy (SBRT): Technological innovation and application in gynecologic oncology.

    Science.gov (United States)

    Higginson, Daniel S; Morris, David E; Jones, Ellen L; Clarke-Pearson, Daniel; Varia, Mahesh A

    2011-03-01

    Stereotactic body radiotherapy (SBRT) is a novel form of noninvasive, highly conformal radiation treatment that delivers a high dose to tumor. The advantage of the technique resides in its ability to provide a high dose to tumor but spare normal tissues to an extent not previously possible. In this paper we will provide an introduction and review of this technology with regard to its use in gynecologic malignancies. Preliminary results from our experience are presented for the purpose of illustrating the range of SBRT applications in gynecologic oncology. A comprehensive literature review was conducted and our experience from the past three years was reviewed. Six case series are published that report results of SBRT for gynecologic malignancies. Sixteen gynecologic patients have been treated with SBRT at our institution. Treatment sites include pelvic and periaortic nodes (9 patients), oligometastatic disease (2), and cervical or endometrial primary tumors when other conventional external radiation or brachytherapy techniques were unsuitable (5). Preliminary follow-up at a median of 11 months (range, 0.3-33 months) demonstrates 79% locoregional control, 43% distant failure, and 50% overall survival. SBRT boosts to macroscopic periaortic node recurrences and other sites seem to provide local control and a possibility of long-term disease-free survival in carefully selected patients. Previously this had been difficult to achieve with conventional radiotherapy because of the proximity of periaortic nodes to small bowel. SBRT also offers a novel approach for minimally invasive treatment in the management of gynecological cancer where current surgical and radiotherapy techniques are unsuitable. Copyright © 2010 Elsevier Inc. All rights reserved.

  7. A simple method for 3D lesion reconstruction from two projected angiographic images: implementation to a stereotactic radiotherapy treatment planning system

    International Nuclear Information System (INIS)

    Theodorou, K.; Kappas, C.; Gaboriaud, G.; Mazal, A.D.; Petrascu, O.; Rosenwald, J.C.

    1997-01-01

    Introduction: The most used imaging modality for diagnosis and localisation of arteriovenous malformations (AVMs) treated with stereotactic radiotherapy is angiography. The fact that the angiographic images are projected images imposes the need of the 3D reconstruction of the lesion. This, together with the 3D head anatomy from CT images could provide all the necessary information for stereotactic treatment planning. We have developed a method to combine the complementary information provided by angiography and 2D computerized tomography, matching the reconstructed AVM structure with the reconstructed head of the patient. Materials and methods: The ISIS treatment planning system, developed at Institute Curie, has been used for image acquisition, stereotactic localisation and 3D visualisation. A series of CT slices are introduced in the system as well as two orthogonal angiographic projected images of the lesion. A simple computer program has been developed for the 3D reconstruction of the lesion and for the superposition of the target contour on the CT slices of the head. Results and conclusions: In our approach we consider that the reconstruction can be made if the AVM is approximated with a number of adjacent ellipses. We assessed the method comparing the values of the reconstructed and the actual volumes of the target using linear regression analysis. For treatment planning purposes we overlapped the reconstructed AVM on the CT slices of the head. The above feature is to our knowledge a feature that the majority of the commercial stereotactic radiotherapy treatment planning system could not provide. The implementation of the method into ISIS TPS shows that we can reliably approximate and visualize the target volume

  8. A pencil beam dose calculation model for CyberKnife system

    Energy Technology Data Exchange (ETDEWEB)

    Liang, Bin; Li, Yongbao; Liu, Bo; Zhou, Fugen [Image Processing Center, Beihang University, Beijing 100191 (China); Xu, Shouping [Department of Radiation Oncology, PLA General Hospital, Beijing 100853 (China); Wu, Qiuwen, E-mail: Qiuwen.Wu@Duke.edu [Department of Radiation Oncology, Duke University Medical Center, Durham, North Carolina 27710 (United States)

    2016-10-15

    Purpose: CyberKnife system is initially equipped with fixed circular cones for stereotactic radiosurgery. Two dose calculation algorithms, Ray-Tracing and Monte Carlo, are available in the supplied treatment planning system. A multileaf collimator system was recently introduced in the latest generation of system, capable of arbitrarily shaped treatment field. The purpose of this study is to develop a model based dose calculation algorithm to better handle the lateral scatter in an irregularly shaped small field for the CyberKnife system. Methods: A pencil beam dose calculation algorithm widely used in linac based treatment planning system was modified. The kernel parameters and intensity profile were systematically determined by fitting to the commissioning data. The model was tuned using only a subset of measured data (4 out of 12 cones) and applied to all fixed circular cones for evaluation. The root mean square (RMS) of the difference between the measured and calculated tissue-phantom-ratios (TPRs) and off-center-ratio (OCR) was compared. Three cone size correction techniques were developed to better fit the OCRs at the penumbra region, which are further evaluated by the output factors (OFs). The pencil beam model was further validated against measurement data on the variable dodecagon-shaped Iris collimators and a half-beam blocked field. Comparison with Ray-Tracing and Monte Carlo methods was also performed on a lung SBRT case. Results: The RMS between the measured and calculated TPRs is 0.7% averaged for all cones, with the descending region at 0.5%. The RMSs of OCR at infield and outfield regions are both at 0.5%. The distance to agreement (DTA) at the OCR penumbra region is 0.2 mm. All three cone size correction models achieve the same improvement in OCR agreement, with the effective source shift model (SSM) preferred, due to their ability to predict more accurately the OF variations with the source to axis distance (SAD). In noncircular field validation

  9. Management of Spinal Metastases From Renal Cell Carcinoma Using Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Nguyen, Quynh-Nhu; Shiu, Almon S.; Rhines, Laurence D.; Wang He; Allen, Pamela K.; Wang, Xin Shelley; Chang, Eric L.

    2010-01-01

    Purpose: To evaluate the outcomes associated with stereotactic body radiotherapy (SBRT) in the management of spinal metastases from renal cell carcinoma (RCC). Methods and Materials: SBRT was used in the treatment of patients with spinal metastases from RCC. Patients received either 24 Gy in a single fraction, 27 Gy in three fractions, or 30 Gy delivered in five fractions. Effectiveness of SBRT with respect to tumor control and palliation of pain was assessed using patient-reported outcomes. Results: A total of 48 patients with 55 spinal metastases were treated with SBRT with a median follow-up time of 13.1 months (range, 3.3-54.5 months). The actuarial 1-year spine tumor progression free survival was 82.1%. At pretreatment baseline, 23% patients were pain free; at 1 month and 12 months post-SBRT, 44% and 52% patients were pain free, respectively. No Grade 3-4 neurologic toxicity was observed. Conclusions: The data support SBRT as a safe and effective treatment modality that can be used to achieve good tumor control and palliation of pain associated with RCC spinal metastases. Further evaluation with randomized trials comparing SBRT to conventional radiotherapy may be warranted.

  10. Initial clinical results of linac-based stereotactic radiosurgery and stereotactic radiotherapy for pituitary adenomas

    International Nuclear Information System (INIS)

    Mitsumori, Michihide; Shrieve, Dennis C.; Alexander, Eben; Kaiser, Ursula B.; Richardson, Gary E.; Black, Peter McL.; Loeffler, Jay S.

    1998-01-01

    Purpose: To retrospectively evaluate the initial clinical results of stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (SRT) for pituitary adenomas with regard to tumor and hormonal control and adverse effects of the treatment. Subjects and Methods: Forty-eight patients with pituitary adenoma who underwent SRS or SRT between September 1989 and September 1995 were analyzed. Of these, 18 received SRS and 30 received SRT. The median tumor volumes were 1.9 cm 3 for SRS and 5.7 cm 3 for SRT. Eleven of the SRS and 18 of the SRT patients were hormonally active at the time of the initial diagnosis. Four of the SRS and none of the SRT patients had a history of prior radiation therapy. Both SRS and SRT were performed using a dedicated stereotactic 6-MV linear accelerator (LINAC). The dose and normalization used for the SRS varied from 1000 cGy at 85% of the isodose line to 1500 cGy at 65% of the isodose line. For SRT patients, a total dose of 4500 cGy at 90% or 95% of the isodose line was delivered in 25 fractions of 180 cGy daily doses. Results: Disease control--The three year tumor control rate was 91.1% (100% for SRS and 85.3% for SRT). Normalization of the hormonal abnormality was achieved in 47% of the 48 patients (33% for SRS and 54% for SRT). The average time required for normalization was 8.5 months for SRS and 18 months for SRT. Adverse effects--The 3-year rate of freedom from central nervous system adverse effects was 89.7% (72.2% for SRS and 100% for SRT). Three patients who received SRS for a tumor in the cavernous sinus developed a ring enhancement in the temporal lobe as shown by follow-up magnetic resonance imaging. Two of these cases were irreversible and were considered to be radiation necrosis. None of the 48 patients developed new neurocognitive or visual disorders attributable to the irradiation. The incidence of endocrinological adverse effects were similar in the two groups, resulting in 3-year rates of freedom from newly

  11. Reirradiation of recurrent node-positive non-small cell lung cancer after previous stereotactic radiotherapy for stage I disease. A multi-institutional treatment recommendation

    International Nuclear Information System (INIS)

    Nieder, Carsten; Ruysscher, Dirk de; Gaspar, Laurie E.; Guckenberger, Matthias; Mehta, Minesh P.; Cheung, Patrick; Sahgal, Arjun

    2017-01-01

    Practice guidelines have been developed for early-stage and locally advanced non-small cell lung cancer (NSCLC). However, many common clinical scenarios still require individualized decision making. This is true for locoregional relapse after initial stereotactic radiotherapy (stereotactic body radiation therapy or stereotactic ablative radiotherapy; SBRT or SABR), an increasingly utilized curative treatment option for stage I NSCLC. A consortium of expert radiation oncologists was established with the aim of providing treatment recommendations. In this scenario, a case was distributed to six radiation oncologists who provided their institutions' treatment recommendations. In this case, a patient developed local and mediastinal relapse after SABR (45 Gy, 3 fractions), comparable to the tumor burden in de novo stage IIIA NSCLC. Treatment recommendations were tabulated and a consensus conclusion was developed. Three institutions recommended evaluation for surgery. If the patient was not a surgical candidate, and/or refused surgery, definitive chemoradiation was recommended, including retreating the primary to full dose. European participants were more in favor of a non-surgical approach. None of the participants were reluctant to prescribe reirradiation, but two institutions prescribed doses lower than 60 Gy. Platinum-based doublets together with intensity-modulated radiotherapy were preferred. The institutional recommendations reflect the questions and uncertainties discussed in current stage III guidelines. All institutions agreed that previous SABR is not a contraindication for salvage chemoradiation. In the absence of high-quality prospective trials for recurrent NSCLC, all treatment options recommended in current guidelines for stage III disease can be considered in clinical scenarios such as this. (orig.) [de

  12. Fractionated Stereotactic Radiotherapy of Vestibular Schwannomas Accelerates Hearing Loss

    Energy Technology Data Exchange (ETDEWEB)

    Rasmussen, Rune, E-mail: rune333@gmail.com [Department of Neurosurgery, Rigshospitalet, Copenhagen (Denmark); Claesson, Magnus [Department of Neurosurgery, Rigshospitalet, Copenhagen (Denmark); Stangerup, Sven-Eric [Ear, Nose, and Throat Department, Rigshospitalet, Copenhagen (Denmark); Roed, Henrik [Department of Radiation Oncology, Rigshospitalet, Copenhagen (Denmark); Christensen, Ib Jarle [Finsen Laboratory, Rigshospitalet, Copenhagen (Denmark); Caye-Thomasen, Per [Ear, Nose, and Throat Department, Rigshospitalet, Copenhagen (Denmark); Juhler, Marianne [Department of Neurosurgery, Rigshospitalet, Copenhagen (Denmark)

    2012-08-01

    Objective: To evaluate long-term tumor control and hearing preservation rates in patients with vestibular schwannoma treated with fractionated stereotactic radiotherapy (FSRT), comparing hearing preservation rates to an untreated control group. The relationship between radiation dose to the cochlea and hearing preservation was also investigated. Methods and Materials: Forty-two patients receiving FSRT between 1997 and 2008 with a minimum follow-up of 2 years were included. All patients received 54 Gy in 27-30 fractions during 5.5-6.0 weeks. Clinical and audiometry data were collected prospectively. From a 'wait-and-scan' group, 409 patients were selected as control subjects, matched by initial audiometric parameters. Radiation dose to the cochlea was measured using the original treatment plan and then related to changes in acoustic parameters. Results: Actuarial 2-, 4-, and 10-year tumor control rates were 100%, 91.5%, and 85.0%, respectively. Twenty-one patients had serviceable hearing before FSRT, 8 of whom (38%) retained serviceable hearing at 2 years after FSRT. No patients retained serviceable hearing after 10 years. At 2 years, hearing preservation rates in the control group were 1.8 times higher compared with the group receiving FSRT (P=.007). Radiation dose to the cochlea was significantly correlated to deterioration of the speech reception threshold (P=.03) but not to discrimination loss. Conclusion: FSRT accelerates the naturally occurring hearing loss in patients with vestibular schwannoma. Our findings, using fractionation of radiotherapy, parallel results using single-dose radiation. The radiation dose to the cochlea is correlated to hearing loss measured as the speech reception threshold.

  13. Fractionated Stereotactic Radiotherapy of Vestibular Schwannomas Accelerates Hearing Loss

    International Nuclear Information System (INIS)

    Rasmussen, Rune; Claesson, Magnus; Stangerup, Sven-Eric; Roed, Henrik; Christensen, Ib Jarle; Cayé-Thomasen, Per; Juhler, Marianne

    2012-01-01

    Objective: To evaluate long-term tumor control and hearing preservation rates in patients with vestibular schwannoma treated with fractionated stereotactic radiotherapy (FSRT), comparing hearing preservation rates to an untreated control group. The relationship between radiation dose to the cochlea and hearing preservation was also investigated. Methods and Materials: Forty-two patients receiving FSRT between 1997 and 2008 with a minimum follow-up of 2 years were included. All patients received 54 Gy in 27-30 fractions during 5.5-6.0 weeks. Clinical and audiometry data were collected prospectively. From a “wait-and-scan” group, 409 patients were selected as control subjects, matched by initial audiometric parameters. Radiation dose to the cochlea was measured using the original treatment plan and then related to changes in acoustic parameters. Results: Actuarial 2-, 4-, and 10-year tumor control rates were 100%, 91.5%, and 85.0%, respectively. Twenty-one patients had serviceable hearing before FSRT, 8 of whom (38%) retained serviceable hearing at 2 years after FSRT. No patients retained serviceable hearing after 10 years. At 2 years, hearing preservation rates in the control group were 1.8 times higher compared with the group receiving FSRT (P=.007). Radiation dose to the cochlea was significantly correlated to deterioration of the speech reception threshold (P=.03) but not to discrimination loss. Conclusion: FSRT accelerates the naturally occurring hearing loss in patients with vestibular schwannoma. Our findings, using fractionation of radiotherapy, parallel results using single-dose radiation. The radiation dose to the cochlea is correlated to hearing loss measured as the speech reception threshold.

  14. Preliminary experience of extra-skull radiotherapy in stereotaxic conditions by Cyberknife at the Alexis-Vautrin Centre; Experience preliminaire de radiotherapie en conditions stereoxaques extracranienne par Cyberknife au centre Alexis-Vautrin

    Energy Technology Data Exchange (ETDEWEB)

    Peiffert, D.; Beckendorf, V.; Marchesi, V.; Noel, A. [Centre Alexis Vautrin, 54 - Vandoeuvre les Nancy (France); Noel, G. [Centre Paul Strauss, 67 -Strasbourg (France); Maingon, P. [Centre Georges Francois Leclerc, 21 - Dijon (France); Bosset, J.F. [Centre Hospitalier Universitaire, 25 - Besancon (France); Unterreiner, M. [Centre Francois Baclesse, 14 - Caen (France)

    2007-11-15

    The objective of this study is to evaluate the feasibility of the Cyberknife use for extra cerebral tumors by dint of' x.sight' osseous location for para-spinous lesions and 'tracking synchrony' for mobile targets. In conclusion, a training curve is necessary for the patients selection and the treatment implementation. The implantation and follow-up of the pellets need a trained team. A good cooperation of the patient is necessary; the carcinological follow-up will be analyzed ulteriorly. (N.C.)

  15. Residual F-18-FDG-PET Uptake 12 Weeks After Stereotactic Ablative Radiotherapy for Stage I Non-Small-Cell Lung Cancer Predicts Local Control

    NARCIS (Netherlands)

    Bollineni, Vikram Rao; Widder, Joachim; Pruim, Jan; Langendijk, Johannes A.; Wiegman, Erwin M.

    2012-01-01

    Purpose: To investigate the prognostic value of [F-18]fluorodeoxyglucose positron emission tomography (FDG-PET) uptake at 12 weeks after stereotactic ablative radiotherapy (SABR) for stage I non-small-cell lung cancer (NSCLC). Methods and Materials: From November 2006 to February 2010, 132 medically

  16. Nonrandom Intrafraction Target Motions and General Strategy for Correction of Spine Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Ma Lijun; Sahgal, Arjun; Hossain, Sabbir; Chuang, Cynthia; Descovich, Martina; Huang, Kim; Gottschalk, Alex; Larson, David A.

    2009-01-01

    Purpose: To characterize nonrandom intrafraction target motions for spine stereotactic body radiotherapy and to develop a method of correction via image guidance. The dependence of target motions, as well as the effectiveness of the correction strategy for lesions of different locations within the spine, was analyzed. Methods and Materials: Intrafraction target motions for 64 targets in 64 patients treated with a total of 233 fractions were analyzed. Based on the target location, the cases were divided into three groups, i.e., cervical (n = 20 patients), thoracic (n = 20 patients), or lumbar-sacrum (n = 24 patients) lesions. For each case, time-lag autocorrelation analysis was performed for each degree of freedom of motion that included both translations (x, y, and z shifts) and rotations (roll, yaw, and pitch). A general correction strategy based on periodic interventions was derived to determine the time interval required between two adjacent interventions, to overcome the patient-specific target motions. Results: Nonrandom target motions were detected for 100% of cases regardless of target locations. Cervical spine targets were found to possess the highest incidence of nonrandom target motion compared with thoracic and lumbar-sacral lesions (p < 0.001). The average time needed to maintain the target motion to within 1 mm of translation or 1 deg. of rotational deviation was 5.5 min, 5.9 min, and 7.1 min for cervical, thoracic, and lumbar-sacrum locations, respectively (at 95% confidence level). Conclusions: A high incidence of nonrandom intrafraction target motions was found for spine stereotactic body radiotherapy treatments. Periodic interventions at approximately every 5 minutes or less were needed to overcome such motions.

  17. Improved patient repositioning accuracy by integrating an additional jaw fixation into a high precision face mask system in stereotactic radiotherapy of the head

    International Nuclear Information System (INIS)

    Lopatta, E.; Liesenfeld, S.M.; Bank, P.; Guenther, R.; Wiezorek, T.; Wendt, T.G.; Wurm, R.

    2003-01-01

    Background: For high precision radiotherapy of the neurocranium a precise, reproducible positioning technique is the basic pre-requisite. The aim of this study was to assess the influence of a modification of the commercially available stereotactical BrainLab trademark -head mask system on accuracy in patient positioning during fractionated radiotherapy. Material and Methods: 29 patients were treated with stereotactic radiotherapy of the head. Immobilization was provided by a two layer thermoplastic mask system (BrainLab trademark). 18 of these patients received an additional custom made fixation either of the upper jaw (OKF) or of the mandibula (UKF). The positioning accuracy was assessed by measurements of the shifting of anatomical landmarks in relation to therigid mask system on biplanar simulator films using a digital imaging system. Before each measurement a fine adjustment of the simulator to an optical ring system was performed. The reference radiographs were done just before CT-planning. During a 2-7 weeks lasting course of radiotherapy displacement measurements in relation to the reference images for all three dimensions (z, y and x) were done once a week. In 29 patients 844 measurements were analyzed. Results: An additional jaw fixation improves the reproducibility of patient positioning significantly in all three spatial dimensions. The standard deviation in lateral direction (x) was 0.6 mm with jaw fixation vs. 0.7 mm without jaw fixation (p [de

  18. LINAC based stereotactic radiotherapy of uveal melanoma: 4 years clinical experience

    International Nuclear Information System (INIS)

    Dieckmann, Karin; Georg, Dietmar; Zehetmayer, Martin; Bogner, Joachim; Georgopoulos, Michael; Poetter, Richard

    2003-01-01

    Purpose: To study local tumor control and radiogenic side effects after fractionated LINAC based stereotactic radiotherapy for selected uveal melanoma. Patients and methods: Between June 1997 and March 2001, 90 patients suffering from uveal melanoma were treated at a LINAC with 6 MV. The head was immobilized with a modified stereotactic frame system (BrainLAB). For stabilization of the eye position a light source was integrated into the mask system in front of the healthy or the diseased eye. A mini-video camera was used for on-line eye movement control. Tumors included in the study were either located unfavorably with respect to macula and optical disc ( 7 mm. Median tumor volume was 305±234 mm 3 (range 70-1430 mm 3 ), and mean tumor height was 5.4±2.3 mm (range 2.7-15.9 mm). Total doses of 70 (single dose 14 Gy at 80% isodose) or 60 Gy (single dose 12 Gy at 80% isodose) were applied in five fractions within 10 days. The first fractionation results in total dose (TD) (2 Gy) of 175 Gy for tumor and 238 Gy for normal tissue, corresponding values for the second fractionation schedule are 135 and 180 Gy, respectively. Results: After a median follow-up of 20 months (range 1-48 months) local control was achieved in 98% (n=88). The mean relative tumor reductions were 24, 27, and 37% after 12, 24 and 36 months. Three patients (3.3%) developed metastases. Secondary enucleation was performed in seven patients (7.7%). Long term side effects were retinopathy (25.5%), cataract (18.9%), optic neuropathy (20%), and secondary neovascular glaucoma (8.8%). Conclusion: Fractionated LINAC based stereotactic photon beam therapy in conjunction with a dedicated eye movement control system is a highly effective method to treat unfavorably located uveal melanoma. Total doses of 60 Gy (single dose 12 Gy) are considered to be sufficient to achieve good local tumor control

  19. Stereotactic Body Radiotherapy for Recurrent or Oligometastatic Uterine Cervix Cancer: A Cooperative Study of the Korean Radiation Oncology Group (KROG 14-11).

    Science.gov (United States)

    Park, Hae Jin; Chang, Ah Ram; Seo, Youngseok; Cho, Chul Koo; Jang, Won-Il; Kim, Mi Sook; Choi, Chulwon

    2015-09-01

    To evaluate local control and patient survival for recurrent or oligometastatic uterine cervical cancer treated with stereotactic body radiotherapy (SBRT) using CyberKnife, and to demonstrate the safety of SBRT. Between 2002 and 2013, 100 recurrent or oligometastatic lesions in 85 patients were treated with SBRT at three Institutions. SBRT sites were within the previous RT field in 59 and partially overlapped in nine. SBRT sites included three local recurrences, 89 lymph node metastases, and eight distant metastases. Patients were treated with a median dose of 39 Gy in three fractions, which was equivalent to a biologically effective dose (BED) of 90 Gy. The median follow-up period was 20.4 months. Local failure occurred in 17 out of 100 SBRT-treated sites. The 2-year and 5-year local progression-free survival rates were 82.5% and 78.8%, respectively. Eleven local failures occurred within the previous RT field. The 2-year and 5-year overall survival rates were 57.5% and 32.9%, respectively. BED >90 Gy (p=0.072) and >69 Gy (p=0.059) and longer disease-free interval (p=0.065) predicted marginally superior local control. Re-irradiation appeared to be related to inferior local control (p<0.001), but the SBRT BED in this group was much lower than the dose in the other group (median BED, 79 Gy vs. 90 Gy). Chronic toxicities of grade 3 or more occurred in five cases. SBRT for recurrent or oligometastatic cervical cancer resulted in excellent local control, especially with a long disease-free interval and high BED treatment, with acceptable toxicities. Therefore, SBRT can be considered a therapeutic option for these patients. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  20. Stereotactic Body Radiotherapy for Oligometastatic Lung Tumors

    International Nuclear Information System (INIS)

    Norihisa, Yoshiki; Nagata, Yasushi; Takayama, Kenji; Matsuo, Yukinori; Sakamoto, Takashi; Sakamoto, Masato; Mizowaki, Takashi; Yano, Shinsuke; Hiraoka, Masahiro

    2008-01-01

    Purpose: Since 1998, we have treated primary and oligometastatic lung tumors with stereotactic body radiotherapy (SBRT). The term 'oligometastasis' is used to indicate a small number of metastases limited to an organ. We evaluated our clinical experience of SBRT for oligometastatic lung tumors. Methods and Materials: A total of 34 patients with oligometastatic lung tumors were included in this study. The primary involved organs were the lung (n = 15), colorectum (n = 9), head and neck (n = 5), kidney (n = 3), breast (n = 1), and bone (n = 1). Five to seven, noncoplanar, static 6-MV photon beams were used to deliver 48 Gy (n = 18) or 60 Gy (n = 16) at the isocenter, with 12 Gy/fraction within 4-18 days (median, 12 days). Results: The overall survival rate, local relapse-free rate, and progression-free rate at 2 years was 84.3%, 90.0%, and 34.8%, respectively. No local progression was observed in tumors irradiated with 60 Gy. SBRT-related pulmonary toxicities were observed in 4 (12%) Grade 2 cases and 1 (3%) Grade 3 case. Patients with a longer disease-free interval had a greater overall survival rate. Conclusion: The clinical result of SBRT for oligometastatic lung tumors in our institute was comparable to that after surgical metastasectomy; thus, SBRT could be an effective treatment of pulmonary oligometastases

  1. SU-F-T-633: Cyberknife Boost Versus Conventional Tandem and Ovoid Treatment for Cervical Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Santoro, J; Witten, M; Haas, J [Winthrop University Hospital, Lynbrook, NY (United States)

    2016-06-15

    Purpose: Brachytherapy has been the standard of care for cervical cancer for 100 years. The treatment can be administered using an HDR (high dose rate) remote afterloader with a {sup 192}Ir source in an outpatient setting, a PDR afterloader with a {sup 192}Ir source, or with LDR manually loaded or a remote afterloader utilizing {sup 192}Ir or {sup 137}Cs sources in an inpatient setting. The procedure involves the placement of a tandem and ovoid, tandem and ring, or tandem and cylinder applicator in an operating room setting with the patient under general anesthesia. Inaccuracies introduced into the process occurring between placement of the applicator and actual delivery can introduce uncertainty into the actual dose delivered to the tumor and critical organs. In this study we seek to investigate the dosimetric difference between an SBRT-based radiotherapy boost and conventional Brachytherapy in treating cervical cancer. Methods: Five HDR tandem and ovoid patients were planned using the Brachyvision treatment planning system and treated in four fractions using the Varian Varisource afterloader (Varian Medical Systems). For the same cohort, the patient planning CTs were imported into Multiplan (Accuray Inc) and a dose/fractionation-equivalent CyberKnife SBRT plan was retrospectively generated. Dosimetric quantities such as target/CTV D90, V90, D2cc for rectum, bladder, and bowel were measured and compared between the two modalities. Results: The CTV D90 for the tandem and ovoid was 2540cGy (90.7%) and 3009cGy (107.5%) for the CyberKnife plan. The D2cc for the rectum, bladder, and bowel were 1576cGy, 1641cGy, and 996cGy for the tandem and ovoid and 1374cGy, 1564cGy, and 1547cGy for CyberKnife. Conclusion: The D2cc doses to critical structures are comparable in both modalities. The CTV coverage is far superior for the CyberKnife plan. The dose distribution for CyberKnife has the advantage of increased conformality and lower maximum CTV dose.

  2. Dosimetric and motion analysis of margin-intensive therapy by stereotactic ablative radiotherapy for resectable pancreatic cancer

    Directory of Open Access Journals (Sweden)

    Heinzerling John H

    2011-10-01

    Full Text Available Abstract Background The retroperitoneal margin is a common site of positive surgical margins in patients with resectable pancreatic cancer. Preoperative margin-intensive therapy (MIT involves delivery of a single high dose of ablative radiotherapy (30 Gy focused on this surgically inaccessible margin, utilizing stereotactic techniques in an effort to reduce local failure following surgery. In this study, we investigated the motion of regional organs at risk (OAR utilizing 4DCT, evaluated the dosimetric effects of abdominal compression (AC to reduce regional motion, and compared various planning techniques to optimize MIT. Methods 10 patients were evaluated with 4DCT scans. All 10 patients had scans using AC and seven of the 10 patients had scans both with and without AC. The peak respiratory abdominal organ and major vessel centroid excursion was measured. A "sub-GTV" region was defined by a radiation oncologist and surgical oncologist encompassing the retroperitoneal margin typically lateral and posterior to the superior mesenteric artery (SMA, and a 3-5 mm margin was added to constitute the PTV. Identical 3D non-coplanar SABR (3DSABR plans were designed for the average compression and non-compression scans. Compression scans were planned with 3DSABR, coplanar IMRT (IMRT, and Cyberknife (CK planning techniques. Dose volume analysis was undertaken for various endpoints, comparing OAR doses with and without AC and for different planning methods. Results The mean PTV size was 20.2 cm3. Regional vessel motion of the SMA, celiac trunk, and renal vessels was small ( 5 mm, so AC has been used in all patients enrolled thus far. AC did not significantly increase OAR dose including the stomach and traverse colon. There were several statistically significant differences in the doses to OARs as a function of the type of planning modality used. Conclusions AC does not significantly reduce the limited motion of structures in close proximity to the MIT target

  3. Dosimetric and geometric evaluation of a novel stereotactic radiotherapy device for breast cancer: The GammaPod Trade-Mark-Sign

    Energy Technology Data Exchange (ETDEWEB)

    Mutaf, Yildirim D.; Yi, Byong Yong; Prado, Karl; D' Souza, Warren D.; Regine, William F.; Feigenberg, Steven J. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 (United States); Zhang Jin [Xcision Medical Systems, Columbia, Maryland 21045 (United States); Yu, Cedric X. [Department of Radiation Oncology, University of Maryland School of Medicine, Baltimore, Maryland 21201 and Xcision Medical Systems, Columbia, Maryland 21045 (United States)

    2013-04-15

    Purpose: A dedicated stereotactic gamma irradiation device, the GammaPod Trade-Mark-Sign from Xcision Medical Systems, was developed specifically to treat small breast cancers. This study presents the first evaluation of dosimetric and geometric characteristics from the initial prototype installed at University of Maryland Radiation Oncology Department. Methods: The GammaPod Trade-Mark-Sign stereotactic radiotherapy device is an assembly of a hemi-spherical source carrier containing 36 {sup 60}Co sources, a tungsten collimator, a dynamically controlled patient support table, and the breast immobilization system which also functions as a stereotactic frame. The source carrier contains the sources in six columns spaced longitudinally at 60 Degree-Sign intervals and it rotates together with the variable-size collimator to form 36 noncoplanar, concentric arcs focused at the isocenter. The patient support table enables motion in three dimensions to position the patient tumor at the focal point of the irradiation. The table moves continuously in three cardinal dimensions during treatment to provide dynamic shaping of the dose distribution. The breast is immobilized using a breast cup applying a small negative pressure, where the immobilization cup is embedded with fiducials also functioning as the stereotactic frame for the breast. Geometric and dosimetric evaluations of the system as well as a protocol for absorbed dose calibration are provided. Dosimetric verifications of dynamically delivered patient plans are performed for seven patients using radiochromic films in hypothetical preop, postop, and target-in-target treatment scenarios. Results: Loaded with 36 {sup 60}Co sources with cumulative activity of 4320 Ci, the prototype GammaPod Trade-Mark-Sign unit delivers 5.31 Gy/min at the isocenter using the largest 2.5 cm diameter collimator. Due to the noncoplanar beam arrangement and dynamic dose shaping features, the GammaPod Trade-Mark-Sign device is found to deliver

  4. Influence of rotational setup error on tumor shift in bony anatomy matching measured with pulmonary point registration in stereotactic body radiotherapy for early lung cancer

    International Nuclear Information System (INIS)

    Suzuki, Osamu; Nishiyama, Kinji; Ueda, Yoshihiro; Miyazaki, Masayoshi; Tsujii, Katsutomo

    2012-01-01

    The objective of this study was to examine the correlation between the patient rotational error measured with pulmonary point registration and tumor shift after bony anatomy matching in stereotactic body radiotherapy for lung cancer. Twenty-six patients with lung cancer who underwent stereotactic body radiotherapy were the subjects. On 104 cone-beam computed tomography measurements performed prior to radiation delivery, rotational setup errors were measured with point registration using pulmonary structures. Translational registration using bony anatomy matching was done and the three-dimensional vector of tumor displacement was measured retrospectively. Correlation among the three-dimensional vector and rotational error and vertebra-tumor distance was investigated quantitatively. The median and maximum rotational errors of the roll, pitch and yaw were 0.8, 0.9 and 0.5, and 6.0, 4.5 and 2.5, respectively. Bony anatomy matching resulted in a 0.2-1.6 cm three-dimensional vector of tumor shift. The shift became larger as the vertebra-tumor distance increased. Multiple regression analysis for the three-dimensional vector indicated that in the case of bony anatomy matching, tumor shifts of 5 and 10 mm were expected for vertebra-tumor distances of 4.46 and 14.1 cm, respectively. Using pulmonary point registration, it was found that the rotational setup error influences the tumor shift. Bony anatomy matching is not appropriate for hypofractionated stereotactic body radiotherapy with a tight margin. (author)

  5. Fractionated stereotactically guided radiotherapy for pharmacoresistant epilepsy; Fraktionierte, stereotaktisch gefuehrte Radiotherapie der pharmakoresistenten Epilepsie

    Energy Technology Data Exchange (ETDEWEB)

    Grabenbauer, G.G.; Reinhold, C.; Lambrecht, U.; Sauer, R. [Klinik und Poliklinik fuer Strahlentherapie, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Kerling, F.; Pauli, E.; Stefan, H. [Neurologische Klinik, Abt. Epileptologie, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Mueller, R.G. [Inst. fuer Medizinische Physik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany); Ganslandt, O. [Neurochirurgische Klinik, Friedrich-Alexander-Univ. Erlangen-Nuernberg, Erlangen (Germany)

    2003-01-01

    Aim: This prospective study evaluated the efficiency of fractionated stereotactically guided radiotherapy as a treatment of pharmacoresistant temporal lobe epilepsy. Patients and Methods: Inclusion criteria were patients aged between 17 and 65 years with one-sided temporally located focus, without sufficient epilepsy control by, antiepileptic drugs or neurosurgery. Between 1997 and 1999, two groups of six patients each were treated with 21 Gy (7 times 3 Gy) and 30 Gy (15 times 2 Gy). Study end points were seizure frequency, intensity, seizure length and neuropsychological parameters. Results: All patients experienced a marked reduction in seizure frequency. The mean reduction of seizures was 37% (range 9-77%, i.e. seizures reduced from a monthly mean number of 11.75 to 7.52) at 18 months following radiation treatment and 46% (23-94%, i.e. 0.2-23 seizures per month) during the whole follow-up time. Seizure length was reduced in five out of eleven patients and intensity of seizures in seven out of eleven patients. Conclusion: Radiotherapy was identified as safe and effective for pharmacoresistant epilepsy since a very good reduction of seizure frequency was observed. It is no substitute for regular use of antiepileptic drugs, but means an appropriate alternative for patients with contraindication against neurosurgery or insufficient seizure reduction after neurosurgery. (orig.) [German] Ziel: Diese prospektive Studie untersuchte die Effizienz einer fraktionierten stereotaktischen Radiotherapie (RT) bei therapieresistenter Temporallappenepilepsie. Patienten und Methoden: Einschlusskriterien waren Patienten im Alter von 17 bis 65 Jahren, die weder medikamentoes noch epilepsiechirurgisch anfallsfrei wurden und einen einseitigen Fokus aufwiesen. Zwei Patientenkohorten zu je sechs Patienten wurden zwischen 1997 und 1999 einer fraktionierten, stereotaktisch gefuehrten Radiotherapie mit 21 Gy (7 x 3 Gy) bzw. 30 Gy (15 x 2 Gy) unterzogen. Endpunkte der Untersuchung waren

  6. Cardiac embolization of an implanted fiducial marker for hepatic stereotactic body radiotherapy: a case report

    Directory of Open Access Journals (Sweden)

    Hennessey Hooman

    2009-11-01

    Full Text Available Abstract Introduction In liver stereotactic body radiotherapy, reduction of normal tissue irradiation requires daily image guidance. This is typically accomplished by imaging a surrogate to the tumor. The surrogate is often an implanted metal fiducial marker. There are few reports addressing the specific risks of hepatic fiducial marker implantation. These risks are assumed to be similar to percutaneous liver biopsies which are associated with a 1-4% complication rate - almost always pain or bleeding. To the best of our knowledge, we present the first case of such a fiducial marker migrating to the heart. Case presentation An 81-year-old Caucasian man (5 years post-gastrectomy for a gastric adenocarcinoma was referred post-second line palliative chemotherapy for radiotherapy of an isolated liver metastasis. It was decided to proceed with treatment and platinum fiducials were chosen for radiation targeting. Under local anesthesia, three Nester embolization coils (Cook Medical Inc., Bloomington, IN, USA were implanted under computed tomography guidance. Before the placement of each coil, the location of the tip of the delivery needle was confirmed by computed tomography imaging. During the procedure, the third coil unexpectedly migrated through the hepatic vein to the inferior vena cava and lodged at the junction of the vena cava and the right atrium. The patient remained asymptomatic. He was immediately referred to angiography for extraction of the coil. Using fluoroscopic guidance, an EN Snare Retrieval System (Hatch Medical L.L.C., Snellville, GA, USA was introduced through a jugular catheter; it successfully grasped the coil and the coil was removed. The patient was kept overnight for observation and no immediate or delayed complications were encountered due to the migration or retrieval of the coil. He subsequently went on to be treated using the remaining fiducials. Conclusion Implanted fiducial markers are increasingly used for stereotactic

  7. Treatment accuracy of fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Kumar, Shaleen; Burke, Kevin; Nalder, Colin; Jarrett, Paula; Mubata, Cephas; A'Hern, Roger; Humphreys, Mandy; Bidmead, Margaret; Brada, Michael

    2005-01-01

    Background and purpose: To assess the geometric accuracy of the delivery of fractionated stereotactic radiotherapy (FSRT) for brain tumours using the Gill-Thomas-Cosman (GTC) relocatable frame. Accuracy of treatment delivery was measured via portal images acquired with an amorphous silicon based electronic portal imager (EPI). Results were used to assess the existing verification process and to review the current margins used for the expansion of clinical target volume (CTV) to planning target volume (PTV). Patients and methods: Patients were immobilized in a GTC frame. Target volume definition was performed on localization CT and MRI scans and a CTV to PTV margin of 5 mm (based on initial experience) was introduced in 3D. A Brown-Roberts-Wells (BRW) fiducial system was used for stereotactic coordinate definition. The existing verification process consisted of an intercomparison of the coordinates of the isocentres and anatomy between the localization and verification CT scans. Treatment was delivered with 6 MV photons using four fixed non-coplanar conformal fields using a multi-leaf collimator. Portal imaging verification consisted of the acquisition of orthogonal images centred through the treatment isocentre. Digitally reconstructed radiographs (DRRs) created from the CT localization scans were used as reference images. Semi-automated matching software was used to quantify set up deviations (displacements and rotations) between reference and portal images. Results: One hundred and twenty six anterior and 123 lateral portal images were available for analysis for set up deviations. For displacements, the total errors in the cranial/caudal direction were shown to have the largest SD's of 1.2 mm, while systematic and random errors reached SD's of 1.0 and 0.7 mm, respectively, in the cranial/caudal direction. The corresponding data for rotational errors (the largest deviation was found in the sagittal plane) was 0.7 deg. SD (total error), 0.5 deg. (systematic) and 0

  8. A new strategy of CyberKnife treatment system based radiosurgery followed by early use of adjuvant bevacizumab treatment for brain metastasis with extensive cerebral edema.

    Science.gov (United States)

    Wang, Yang; Wang, Enmin; Pan, Li; Dai, Jiazhong; Zhang, Nan; Wang, Xin; Liu, Xiaoxia; Mei, Guanghai; Sheng, Xiaofang

    2014-09-01

    Bevacizumab blocks the effects of vascular endothelial growth factor in leakage-prone capillaries and has been suggested as a new treatment for cerebral radiation edema and necrosis. CyberKnife is a new, frameless stereotactic radiosurgery system. This work investigated the safety and efficacy of CyberKnife followed by early bevacizumab treatment for brain metastasis with extensive cerebral edema. The eligibility criteria of the patients selected for radiosurgery followed by early use of adjuvant bevacizumab treatment were: (1) brain tumors from metastasis with one solitary brain lesion and symptomatic extensive cerebral edema; (2) >18 years of age; (3) the patient refused surgery due to the physical conditions and the risk of surgery; (4) no contraindications for bevacizumab. (5) bevacizumab was applied for a minimum of 2 injections and a maximum of 6 injections with a 2-week interval between treatments, beginning within 2 weeks of the CyberKnife therapy; (6) Karnofsky performance status (KPS) ≥30. Tumor size and edema were monitored by magnetic resonance imaging (MRI). Dexamethasone dosage, KPS, adverse event occurrence and associated clinical outcomes were also recorded. Eight patients were accrued for this new treatment. Radiation dose ranged from 20 to 33 Gy in one to five sessions, prescribed to the 61-71 % isodose line. Bevacizumab therapy was administered 3-10 days after completion of CyberKnife treatment for a minimum of two cycles (5 mg/kg, at 2-week intervals). MRI revealed average reductions of 55.8 % (post-gadolinium) and 63.4 % (T2/FLAIR). Seven patients showed significant clinical neurological improvements. Dexamethasone was reduced in all patients, with five successfully discontinuing dexamethasone treatment 4 weeks after bevacizumab initiation. Hypertension, a bevacizumab-related adverse event, occurred in one patient. After 3-8 months, all patients studied were alive and primary brain metastases were under control, 2 developed new brain

  9. Small-field fractionated radiotherapy with or without stereotactic boost for vestibular schwannoma

    International Nuclear Information System (INIS)

    Kagei, K.; Shirato, H.; Suzuki, K.; Isu, T.; Sawamura, Y.; Sakamoto, T.; Fukuda, S.; Nishioka, T.; Hashimoto, S.; Miyasaka, K.

    1999-01-01

    Purpose: To assess the efficacy and toxicity of small-field fractionated radiotherapy with or without stereotactic boost (SB) for vestibular schwannomas.Methods and materials: Thirty-nine patients with vestibular schwannoma were treated with irradiation between March 1991 and February 1996. Extra-meatal tumor diameters were under 30 mm. Thirty-three patients received small-field fractionated radiotherapy followed by SB. Basic dose schedule was 44 Gy in 22 fractions over 5 1/2 weeks plus 4 Gy in one session. Six patients received small-field fractionated radiotherapy only (40-44 Gy in 20-22 fractions over 5-5 1/2 weeks or 36 Gy in 20 fractions over 5 weeks).< Results: Follow-up ranged from 6 to 69 months (median, 24 months). Tumors decreased in size in 13 cases (33%), were unchanged in 25 (64%), and increased in one (3%). The actuarial 2-year tumor control rate was 97%. Fifteen patients had useful hearing (Gardner-Robertson class 1-2) and 25 patients had testable hearing (class 1-4) before irradiation. The 2-year actuarial rates of useful hearing preservation (free of deterioration from class 1-2 to class 3-5) were 78%. The 2-year actuarial rates of any testable hearing preservation (free of deterioration from class 1-4 to class 5) were 96%. No permanent facial and trigeminal neuropathy developed after irradiation. The 2-year actuarial incidences of facial and trigeminal neuropathies were 8% and 16%, respectively.Conclusions: Small-field fractionated radiotherapy with or without SB provides excellent short-term local control and a relatively low incidence of complications for vestibular schwannoma, although further follow-up is necessary to evaluate the long-term results. (Copyright (c) 1999 Elsevier Science B.V., Amsterdam. All rights reserved.)

  10. Adaptive fractionated stereotactic Gamma Knife radiotherapy of meningioma using integrated stereotactic cone-beam-CT and adaptive re-planning (a-gkFSRT)

    International Nuclear Information System (INIS)

    Stieler, F.; Wenz, F.; Abo-Madyan, Y.; Schweizer, B.; Polednik, M.; Herskind, C.; Giordano, F.A.; Mai, S.

    2016-01-01

    The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49 /0.18 ± 0.20 /0.05 ± 0.36 and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT. (orig.) [de

  11. Stereotactic Body Radiotherapy for Metastatic and Recurrent Ewing Sarcoma and Osteosarcoma

    Directory of Open Access Journals (Sweden)

    Lindsay C. Brown

    2014-01-01

    Full Text Available Background. Radiotherapy has been utilized for metastatic and recurrent osteosarcoma and Ewing sarcoma (ES, in order to provide palliation and possibly prolong overall or progression-free survival. Stereotactic body radiotherapy (SBRT is convenient for patients and offers the possibility of increased efficacy. We report our early institutional experience using SBRT for recurrent and metastatic osteosarcoma and Ewing sarcoma. Methods. We reviewed all cases of osteosarcoma or ES treated with SBRT between 2008 and 2012. Results. We identified 14 patients with a total of 27 lesions from osteosarcoma (n=19 or ES (n=8. The median total curative/definitive SBRT dose delivered was 40 Gy in 5 fractions (range, 30–60 Gy in 3–10 fractions. The median total palliative SBRT dose delivered was 40 Gy in 5 fractions (range, 16–50 Gy in 1–10 fractions. Two grade 2 and 1 grade 3 late toxicities occurred, consisting of myonecrosis, avascular necrosis with pathologic fracture, and sacral plexopathy. Toxicity was seen in the settings of concurrent chemotherapy and reirradiation. Conclusions. This descriptive report suggests that SBRT may be a feasible local treatment option for patients with osteosarcoma and ES. However, significant toxicity can result, and thus systematic study is warranted to clarify efficacy and characterize long-term toxicity.

  12. Emerging radiotherapy technology in a developing country: A single Brazilian institution assessment of stereotactic body radiotherapy application

    Energy Technology Data Exchange (ETDEWEB)

    Moraes, Fabio Ynoe; Bonifacio, Lorine Arias; Neves-Junior, Wellington Pimenta; Hanna, Samir Abdallah; Abreu, Carlos Eduardo Cintra Vita; Arruda, Fernando Freire; Silva, Joao Luis Fernandes; Carvalho, Heloisa Andrade, E-mail: fymoraes@gmail.com [Hospital Sirio-Libanes, Sao Paulo, SP(Brazil)

    2016-11-15

    Objective: To provide a quantitative profile of the indications and use of stereotactic body radiotherapy (SBRT) in a developing country oncology-based institution. In addition, to describe the patient and treatment characteristics, and to provide a temporal analysis. Method: SBRT patients treated from 2007 to 2015 were retrospectively evaluated by two independently investigators. Data were stratified and compared in two periods: first experience (FE) (May 2007 to April 2011), and following experience (FollowE) (May 2011 to April 2015). The following parameters were compared between the groups: total number of treated patients and lesions, treatment site, additional image fusion used, formal protocol adoption, and SBRT planning technique. Results: One hundred and seventy-six (176) patients with 191 lesions were treated: 34 (18%) lesions in the FE and 157 (82%) lesions in FollowE. The majority of lesions were metastases (60.3%), and lung (60.2%) was the most common treatment site, followed by spine (31%), and others (8.8%). An average of 1.4 (±0.6) additional imaging exams for delineation was performed. Conformal 3D radiotherapy planning technique was used in 64.4%, and intensity modulated radiotherapy (IMRT) or volumetric-modulated arc therapy (VMAT) in the remaining 35.6% (p=0.0001). Higher rates of curative treatments were observed in FE, as well as more lung lesions, patients ≥ 70 years, 3D conformal, number of additional images and ECOG 0, and all presented p<0.05. The global rate of protocol statement was 79%, lung treatment being the most stated. Conclusion: SBRT application is rapidly increasing in our setting. Treatment sites and planning techniques are becoming more diversified and complex. (author)

  13. Radiotherapy management of brain metastases using conventional linear accelerator.

    Science.gov (United States)

    Matzenauer, Marcel; Vrana, David; Vlachova, Zuzana; Cwiertka, Karel; Kalita, Ondrej; Melichar, Bohuslav

    2016-09-01

    As treatments for primary cancers continue to improve life expectancy, unfortunately, brain metastases also appear to be constantly increasing and life expectancy for patients with brain metastases is low. Longer survival and improved quality of life may be achieved using localised radiological and surgical approaches in addition to low dose corticosteroids. Stereotactic brain radiotherapy is one rapidly evolving localized radiation treatment. This article describes our experience with stereotactic radiotherapy using a linear accelerator. We reviewed patients treated with stereotactic radiotherapy, from the time of its introduction into daily practice in our Department of Oncology in 2014. We collected the data on patient treatment and predicted survival based on prognostic indices and actual patient outcome. A total of 10 patients were treated by stereotactic radiotherapy, in one case in combination with whole brain radiotherapy and hippocampal sparing. There was no significant treatment related toxicity during the treatment or follow-up and due to the small number of fractions, the overall tolerance of the treatment was excellent. The patient intrafractional movement in all cases was under 1 mm suggesting that 1 mm margin around the CTV to create the PTV is sufficient and also that patient immobilization using the thermoplastic mask compared with invasive techniques, is feasible. We also found that prognostic indices such as the Graded Prognostic Assessment provide accurate predictions of patient survival. Based on our current evidence, patients with brain metastases fit enough, should be considered for stereotactic radiotherapy treatment.

  14. WE-E-BRE-02: BEST IN PHYSICS (THERAPY) - Stereotactic Radiotherapy for Renal Sympathetic Ablation for the Treatment of Refractory Hypertension

    Energy Technology Data Exchange (ETDEWEB)

    Maxim, P; Wheeler, M; Loo, B [Stanford University, Stanford, CA (United States); Maguire, P [Cyberheart, Inc., Sunnyvale, CA (United States)

    2014-06-15

    Purpose: To determine the safety and efficacy of stereotactic radiotherapy as a novel treatment for patients with refractory hypertension in a swine model. Uncontrolled hypertension is a significant contributor to morbidity and mortality, substantially increasing the risk of ischemic stroke, ischemic heart disease, and kidney failure. Methods: High-resolution computed tomography (CT) images of anesthetized pigs were acquired and treatment plans for each renal artery and nerve were developed using our clinically implemented treatment planning system. Stereotactic radiotherapy, 40Gy in single fraction was delivered bilaterally to the renal nerves using a state-of-the-art medical linear accelerator under image guidance utilizing dynamic conformal arcs. Dose to nearby critical organs was evaluated by dosevolume histogram analysis and correlated to toxicity data obtained through follow up pathology analysis. The animals were observed for six months with serial measurements of blood pressure, urine analysis, serum laboratories, and overall clinical and behavioral status. Results: All animals survived to the follow-up point without evidence of renal dysfunction (stable serum creatinine), skin changes, or behavioral changes that might suggest animal discomfort. Plasma norepinephrine levels (ng/ml) were followed monthly for 6 months. The average reduction observed was 63%, with the median reduction at 73.5%. Microscopic evaluation 4–6 weeks after treatment showed evidence of damage to the nerves around treated renal arteries. Considerable attenuation in pan neurofilament expression by immunohistochemistry was observed with some vacuolar changes indicative of injury. There was no histological or immunohistochemical evidence of damage to nearby spinal cord or spinal nerve root structures. Conclusion: Our preclinical studies have shown stereotactic radiotherapy to the renal sympathetic plexus to be safe and effective in reducing blood pressure, thus this approach holds great

  15. WE-E-BRE-02: BEST IN PHYSICS (THERAPY) - Stereotactic Radiotherapy for Renal Sympathetic Ablation for the Treatment of Refractory Hypertension

    International Nuclear Information System (INIS)

    Maxim, P; Wheeler, M; Loo, B; Maguire, P

    2014-01-01

    Purpose: To determine the safety and efficacy of stereotactic radiotherapy as a novel treatment for patients with refractory hypertension in a swine model. Uncontrolled hypertension is a significant contributor to morbidity and mortality, substantially increasing the risk of ischemic stroke, ischemic heart disease, and kidney failure. Methods: High-resolution computed tomography (CT) images of anesthetized pigs were acquired and treatment plans for each renal artery and nerve were developed using our clinically implemented treatment planning system. Stereotactic radiotherapy, 40Gy in single fraction was delivered bilaterally to the renal nerves using a state-of-the-art medical linear accelerator under image guidance utilizing dynamic conformal arcs. Dose to nearby critical organs was evaluated by dosevolume histogram analysis and correlated to toxicity data obtained through follow up pathology analysis. The animals were observed for six months with serial measurements of blood pressure, urine analysis, serum laboratories, and overall clinical and behavioral status. Results: All animals survived to the follow-up point without evidence of renal dysfunction (stable serum creatinine), skin changes, or behavioral changes that might suggest animal discomfort. Plasma norepinephrine levels (ng/ml) were followed monthly for 6 months. The average reduction observed was 63%, with the median reduction at 73.5%. Microscopic evaluation 4–6 weeks after treatment showed evidence of damage to the nerves around treated renal arteries. Considerable attenuation in pan neurofilament expression by immunohistochemistry was observed with some vacuolar changes indicative of injury. There was no histological or immunohistochemical evidence of damage to nearby spinal cord or spinal nerve root structures. Conclusion: Our preclinical studies have shown stereotactic radiotherapy to the renal sympathetic plexus to be safe and effective in reducing blood pressure, thus this approach holds great

  16. Neural stem cell sparing by linac based intensity modulated stereotactic radiotherapy in intracranial tumors

    International Nuclear Information System (INIS)

    Oehler, Julia; Brachwitz, Tim; Wendt, Thomas G; Banz, Nico; Walther, Mario; Wiezorek, Tilo

    2013-01-01

    Neurocognitive decline observed after radiotherapy (RT) for brain tumors in long time survivors is attributed to radiation exposure of the hippocampus and the subventricular zone (SVZ). The potential of sparing capabilities for both structures by optimized intensity modulated stereotactic radiotherapy (IMSRT) is investigated. Brain tumors were irradiated by stereotactic 3D conformal RT or IMSRT using m3 collimator optimized for PTV and for sparing of the conventional OARs (lens, retina, optic nerve, chiasm, cochlea, brain stem and the medulla oblongata). Retrospectively both hippocampi and SVZ were added to the list of OAR and their dose volume histograms were compared to those from two newly generated IMSRT plans using 7 or 14 beamlets (IMSRT-7, IMSRT-14) dedicated for optimized additional sparing of these structures. Conventional OAR constraints were kept constant. Impact of plan complexity and planning target volume (PTV) topography on sparing of both hippocampi and SVZ, conformity index (CI), the homogeneity index (HI) and quality of coverage (QoC) were analyzed. Limits of agreement were used to compare sparing of stem cell niches with either IMSRT-7 or IMSRT-14. The influence of treatment technique related to the topography ratio between PTV and OARs, realized in group A-D, was assessed by a mixed model. In 47 patients CI (p ≤ 0.003) and HI (p < 0.001) improved by IMSRT-7, IMSRT-14, QoC remained stable (p ≥ 0.50) indicating no compromise in radiotherapy. 90% of normal brain was exposed to a significantly higher dose using IMSRT. IMSRT-7 plans resulted in significantly lower biologically effective doses at all four neural stem cell structures, while contralateral neural stem cells are better spared compared to ipsilateral. A further increase of the number of beamlets (IMSRT-14) did not improve sparing significantly, so IMSRT-7 and IMSRT-14 can be used interchangeable. Patients with tumors contacting neither the subventricular zone nor the cortex benefit

  17. Target coverage in image-guided stereotactic body radiotherapy of liver tumors.

    Science.gov (United States)

    Wunderink, Wouter; Méndez Romero, Alejandra; Vásquez Osorio, Eliana M; de Boer, Hans C J; Brandwijk, René P; Levendag, Peter C; Heijmen, Ben J M

    2007-05-01

    To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV(+)) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV(+), derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (> or = 99%) ITV(+) coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (design, patient stability in the SBF should be verified with portal imaging.

  18. Results of patient specific quality assurance for patients undergoing stereotactic ablative radiotherapy for lung lesions

    International Nuclear Information System (INIS)

    Hardcastle, Nicholas; Clements, Natalie; Cramb, Jim; Wanigaratne, Derrick M.; Chesson, Brent; Aarons, Yolanda; Siva, Shankar; Ball, David; Kron, Tomas

    2014-01-01

    Hypofractionated image guided radiotherapy of extracranial targets has become increasingly popular as a treatment modality for inoperable patients with one or more small lesions, often referred to as stereotactic ablative body radiotherapy (SABR). This report details the results of the physical quality assurance (QA) program used for the first 33 lung cancer SABR radiotherapy 3D conformal treatment plans in our centre. SABR involves one or few fractions of high radiation dose delivered in many small fields or arcs with tight margins to mobile targets often delivered through heterogeneous media with non-coplanar beams. We have conducted patient-specific QA similar to the more common intensity modulated radiotherapy QA with particular reference to motion management. Individual patient QA was performed in a Perspex phantom using point dose verification with an ionisation chamber and radiochromic film for verification of the dose distribution both with static and moving detectors to verify motion management strategies. While individual beams could vary by up to 7 %, the total dose in the target was found to be within ±2 % of the prescribed dose for all 33 plans. Film measurements showed qualitative and quantitative agreement between planned and measured isodose line shapes and dimensions. The QA process highlighted the need to account for couch transmission and demonstrated that the ITV construction was appropriate for the treatment technique used. QA is essential for complex radiotherapy deliveries such as SABR. We found individual patient QA helpful in setting up the technique and understanding potential weaknesses in SABR workflow, thus providing confidence in SABR delivery.

  19. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    International Nuclear Information System (INIS)

    Nambu, Atsushi; Tominaga, Lichto; Maehata, Yoshiyasu; Sawada, Eiichi; Araki, Tsutomu; Onishi, Hiroshi; Aoki, Shinichi; Koshiishi, Tsuyota; Kuriyama, Kengo; Komiyama, Takafumi; Marino, Kan; Araya, Masayuki; Saito, Ryo

    2011-01-01

    Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present

  20. Prospective study on stereotactic radiotherapy of limited-stage non-small-cell lung cancer

    DEFF Research Database (Denmark)

    Høyer, Morten; Roed, Henrik; Hansen, Anders Traberg

    2006-01-01

    Purpose: To test the effect of stereotactic body radiotherapy (SBRT) in       the treatment of medically inoperable patients with limited-stage       non-small-cell lung cancer (NSCLC) in a Phase II trial. Methods and       Materials: Forty patients with Stage I NSCLC were treated with SBRT...... resulted in a high       probability of local control and a promising survival rate. The toxicity       after SBRT of lung tumors was moderate. However, deterioration in       performance status, respiratory insufficiency, and other side effects were       observed...

  1. SU-F-T-576: Characterization of Two Dimensional Liquid Filled Detector Array(SRS 1000) in High Precision Cyberknife Robotic Radiosurgery System

    International Nuclear Information System (INIS)

    Muthukumaran, M; Manigandan, D; Murali, V; Chitra, S; Ganapathy, K; Vikraman, S

    2016-01-01

    Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000’s MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.

  2. SU-F-T-576: Characterization of Two Dimensional Liquid Filled Detector Array(SRS 1000) in High Precision Cyberknife Robotic Radiosurgery System

    Energy Technology Data Exchange (ETDEWEB)

    Muthukumaran, M [Apollo Speciality Hospitals, Chennai, Tamil Nadu (India); Manigandan, D [Fortis Cancer Institute, Mohali, Punjab (India); Murali, V; Chitra, S; Ganapathy, K [Apollo Speciality Hospital, Chennai, Tamil Nadu (India); Vikraman, S [Jaypee Hospital – Radiation Onology, Noida, UTTAR PRADESH (India)

    2016-06-15

    Purpose: The aim of the study is to characterize a two dimensional liquid filled detector array SRS 1000 for routine QA in Cyberknife Robotic Radiosurgery system. Methods: SRS 1000 consists of 977 liquid filled ionization chambers and is designed to be used in small field SRS/SBRT techniques. The detector array has got two different spacial resolutions. Till field size of 5.5×5.5 cm the spacial resolution is 2.5mm (center to center) and after that till field size of 11 × 11 cm the spacial resolution is 5mm. The size of the detector is 2.3 × 2.3 0.5 mm with a volume of .003 cc. The CyberKnife Robotic Radiosurgery System is a frameless stereotactic radiosurgery system in which a LINAC is mounted on a robotic manipulator to deliver beams with a high sub millimeter accuracy. The SRS 1000’s MU linearity, stability, reproducibility in Cyberknife Robotic Radiosurgery system was measured and investigated. The output factors for fixed and IRIS collimators for all available collimators (5mm till 60 mm) was measured and compared with the measurement done with PTW pin-point ionization chamber. Results: The MU linearity was measured from 2 MU till 1000 MU for doserates in the range of 700cGy/min – 780 cGy/min and compared with the measurement done with pin point chamber The MU linearity was with in 3%. The detector arrays stability and reproducibility was excellent and was withinin 0.5% The measured output factors showed an agreement of better than 2% when compared with the measurements with pinpoint chamber for both fixed and IRIS collimators with all available field sizes. Conclusion: We have characterised PTW 1000 SRS as a precise and accurate measurement tool for routine QA of Cyberknife Robotic radiosurgery system.

  3. Radiotherapy for Vestibular Schwannomas: A Critical Review

    International Nuclear Information System (INIS)

    Murphy, Erin S.; Suh, John H.

    2011-01-01

    Vestibular schwannomas are slow-growing tumors of the myelin-forming cells that cover cranial nerve VIII. The treatment options for patients with vestibular schwannoma include active observation, surgical management, and radiotherapy. However, the optimal treatment choice remains controversial. We have reviewed the available data and summarized the radiotherapeutic options, including single-session stereotactic radiosurgery, fractionated conventional radiotherapy, fractionated stereotactic radiotherapy, and proton beam therapy. The comparisons of the various radiotherapy modalities have been based on single-institution experiences, which have shown excellent tumor control rates of 91-100%. Both stereotactic radiosurgery and fractionated stereotactic radiotherapy have successfully improved cranial nerve V and VII preservation to >95%. The mixed data regarding the ideal hearing preservation therapy, inherent biases in patient selection, and differences in outcome analysis have made the comparison across radiotherapeutic modalities difficult. Early experience using proton therapy for vestibular schwannoma treatment demonstrated local control rates of 84-100% but disappointing hearing preservation rates of 33-42%. Efforts to improve radiotherapy delivery will focus on refined dosimetry with the goal of reducing the dose to the critical structures. As future randomized trials are unlikely, we suggest regimented pre- and post-treatment assessments, including validated evaluations of cranial nerves V, VII, and VIII, and quality of life assessments with long-term prospective follow-up. The results from such trials will enhance the understanding of therapy outcomes and improve our ability to inform patients.

  4. Continuous versus step-by-step scanning mode of a novel 3D scanner for CyberKnife measurements

    International Nuclear Information System (INIS)

    Al Kafi, M Abdullah; Mwidu, Umar; Moftah, Belal

    2015-01-01

    The purpose of the study is to investigate the continuous versus step-by-step scanning mode of a commercial circular 3D scanner for commissioning measurements of a robotic stereotactic radiosurgery system. The 3D scanner was used for profile measurements in step-by-step and continuous modes with the intent of comparing the two scanning modes for consistency. The profile measurements of in-plane, cross-plane, 15 degree, and 105 degree were performed for both fixed cones and Iris collimators at depth of maximum dose and at 10 cm depth. For CyberKnife field size, penumbra, flatness and symmetry analysis, it was observed that the measurements with continuous mode, which can be up to 6 times faster than step-by-step mode, are comparable and produce scans nearly identical to step-by-step mode. When compared with centered step-by-step mode data, a fully processed continuous mode data gives rise to maximum of 0.50% and 0.60% symmetry and flatness difference respectfully for all the fixed cones and Iris collimators studied. - Highlights: • D scanner for CyberKnife beam data measurements. • Beam data analysis for continuous and step-by-step scan modes. • Faster continuous scanning data are comparable to step-by-step mode scan data.

  5. Radiobiological mechanisms of stereotactic body radiation therapy and stereotactic radiation surgery

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Mi Sook; Kim, Won Woo; Park, In Hwan; Kim, Hee Jong; Lee, Eun Jin; Jung, Jae Hoon [Research Center for Radiotherapy, Korea Institute of Radiological and Medical Sciences, Seoul (Korea, Republic of); Cho, Lawrence Chin Soo; Song, Chang W. [Dept. of Radiation Oncology, University of Minnesota Medical School, Minneapolis (United States)

    2015-12-15

    Despite the increasing use of stereotactic body radiation therapy (SBRT) and stereotactic radiation surgery (SRS) in recent years, the biological base of these high-dose hypo-fractionated radiotherapy modalities has been elusive. Given that most human tumors contain radioresistant hypoxic tumor cells, the radiobiological principles for the conventional multiple-fractionated radiotherapy cannot account for the high efficacy of SBRT and SRS. Recent emerging evidence strongly indicates that SBRT and SRS not only directly kill tumor cells, but also destroy the tumor vascular beds, thereby deteriorating intratumor microenvironment leading to indirect tumor cell death. Furthermore, indications are that the massive release of tumor antigens from the tumor cells directly and indirectly killed by SBRT and SRS stimulate anti-tumor immunity, thereby suppressing recurrence and metastatic tumor growth. The reoxygenation, repair, repopulation, and redistribution, which are important components in the response of tumors to conventional fractionated radiotherapy, play relatively little role in SBRT and SRS. The linear-quadratic model, which accounts for only direct cell death has been suggested to overestimate the cell death by high dose per fraction irradiation. However, the model may in some clinical cases incidentally do not overestimate total cell death because high-dose irradiation causes additional cell death through indirect mechanisms. For the improvement of the efficacy of SBRT and SRS, further investigation is warranted to gain detailed insights into the mechanisms underlying the SBRT and SRS.

  6. Development of real-time tumor tracking system for stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Yamanaka, Seiji; Sasagawa, Tsuyoshi; Uno, Yukimichi

    2011-01-01

    We are now developing the real-time tumor tracking system for stereotactic radiotherapy (SRT) to provide precise information on the location of a tumor and to reduce the irradiation to healthy tissue in a patient. The system has the following features: A motion tracking and processing unit recognizes a gold marker inserted in or near a tumor in real time by the pattern matching of a predetermined template image and acquired X-ray fluoroscopic images. When the gold marker is within a planned area, that is to say, when a tumor enters a target irradiation area, a gate signal is sent to a linear accelerator. A railway unit is equipped with two X-ray tubes and two detectors, which are controlled separately with their own drive mechanism. They travel with high accuracy and reproducibility to the best position for monitoring the gold marker. A synchronization controller controls the timing for X-ray fluoroscopy and the gate signals to the linear accelerator. The controller works for two types of detectors: a color X-ray detector and a flat panel detector (FPD). (author)

  7. Preliminary result in patients with primary hepatoma treated by stereotactic radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Ki Mun; Choi, Ihl Bohng; Kim, In Ah; Choi, Byung Ock; Kang, Young Nam; Han, Sung Tae; Chung, Gyu Won [College of Medicine, Catholic Univ., Seoul (Korea, Republic of); Chai, Gyu Young [College of Medicine, Gyeongsang National Univ., Chinju (Korea, Republic of)

    2001-03-01

    It is not common to evaluate the response of the fractionated stereotactic radiotherapy (SRT) to primary hepatoma as compared with conventional radiotherapy. The purpose of the study was to take the preliminary result on the clinical trial of primary hepatoma by SRT. From July 1999 to March 2000, thirty three patients were hospitalized in the St. Mary's Hospital, and treated with SRT for extracranial tumors. Among them, 13 patients were diagnosed to primary hepatoma and then applied by frameless SRT using 6 MV linac accelerator. There were 12 male and 1 female patients. They had the age of 44-66 year old (median: 59) and the tumor size of 10-825 cc (median: 185 cc). SRT was given to them 3-5 fractions a week (5 Gy/fraction, 90% isodose line) for 2-3 weeks. Median dose of SRT was 50 Gy and the range was 30-50 Gy. Follow-up period ranged from 3 months to 13 months with median of 8 months. After treating SRT to thirteen patients with primary hepatoma, the response of the tumor was examined by abdominal CT: they are classified by 1 complete regression (7.7%), 7 partial regression (53.8%), 4 minimal regression (30.8%), 1 stable disease (7.7%). The positive responses more than partial remission were 8 patients (61.5%) after the treatment. The level of serum alpha-fetoprotein (AFP) after the treatment as compared with pretreatment had been 92.3% decreased. There was no severe complication except dyspepsia 84.6%, mild nausea 69.2%, transient decreased of hepatic function 15.4% and fever 7.7%. SRT to the patients with primary hepatoma was potentially suggested to become the safe and more effective tool than the conventional radiotherapy even though there were relatively short duration of follow-up and small numbers to be tested.

  8. Radiochromic film for individual patient QA in extracranial stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Kron, T.; Clements, N.; Aarons, Y.; Dunn, L.; Chesson, B.; Miller, J.; Roozen, K.; Ball, D.

    2011-01-01

    Introduction: Modern radiotherapy is characterised by increasingly complex radiation delivery such as Intensity Modulated Radiation Therapy (IMRT) or extracranial stereotactic radiotherapy (ESR). It has become common practice to verify the delivery for each patient in IMRT, however, no such methods have been defined to date for ESR. It was the aim of the present work to develop a method to verify the dose distribution for ESR in a moving phantom using radiochromic film. Methods: Radiochromic film (ISP EBT2) was used in a cylindrical film cassette fitted into a QUASAR phantom (Modus Medical). The cassette can be moved forwards and backwards with motion patterns that can mimic the breathing of individual patients. The radiotherapy treatment plans of four patients were re-planned for the phantom. Between 8 and 10 radiation fields of 6 MV photons from a Varian Trilogy linear accelerator were used to deliver target doses between 18 and 26 Gy per fraction. In order to allow for measurements with EBT2 film all monitor units were divided by 3 or 4 resulting in maximum doses not exceeding 10 Gy. The film was evaluated using a transmission scan on an Epson Perfection V700 scanner with 50 dpi spatial resolution (3 colors, 48bit). A calibration curve was used to convert either the red or green component of the scan to dose. Results: Qualitative film analysis found no discernible discrepancies from planned isodose distributions in the stationary images. The dose distribution in the moving phantom was used successfully to confirm the appropriateness of the ITV construction in the planning process. Conclusions: We have developed a QA procedure that accounts for breathing patterns of individual patients in ESR for lung cancer. Radiochromic film was found to be easy to adapt to this process.

  9. Dosimetric impact of a frame-based strategy in stereotactic radiotherapy of lung tumors

    International Nuclear Information System (INIS)

    Waldeland, Einar; Ramberg, Christina; Arnesen, Marius Roethe; Helland, Aaslaug; Brustugun, Odd Terje; Malinen, Eirik

    2012-01-01

    Introduction. Technological innovations have taken stereotactic body radiotherapy (SBRT) from frame-based strategies to image-guided strategies. In this study, cone beam computed tomography (CBCT) images acquired prior to SBRT of patients with lung tumors was used to study the dosimetric impact of a pure frame-based strategy. Material and methods. Thirty patients with inoperable lung tumors were retrospectively analyzed. All patients had received CBCT-guided SBRT with 3 fractions of 15 Gy to the planning target volume (PTV) margin including immobilization in a stereotactic body frame (SBF). Using the set-up corrections from the co-registration of the CBCT with the planning CT, all individual dose plans were recalculated with an isocenter position equal to the initial set-up position. Dose Volume Histogram (DVH) parameters of the recalculated dose plans were then analyzed. Results. The simulated plans showed that 88% of all fractions resulted in minimum 14.5 Gy to the internal target volume (ITV). For the simulated summed treatment (3 fractions per patient), 83% of the patients would minimum receive the prescription dose (45 Gy) to 100% of the ITV and all except one would receive the prescription dose to more than 90% of the ITV. Conclusions. SBRT including SBF, but without image guidance, results in appropriate dose coverage in most cases, using the current margins. With image guidance, margins for SBRT of lung tumors could possibly be reduced

  10. Stereotactic radiosurgery for treatment of brain metastases. A report of the DEGRO Working Group on Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Kocher, Martin; Wittig, Andrea; Piroth, Marc Dieter; Treuer, Harald; Ruge, Maximilian; Seegenschmiedt, Heinrich; Grosu, Anca-Ligia; Guckenberger, Matthias

    2014-01-01

    This report from the Working Group on Stereotaktische Radiotherapie of the German Society of Radiation Oncology (Deutsche Gesellschaft fuer Radioonkologie, DEGRO) provides recommendations for the use of stereotactic radiosurgery (SRS) on patients with brain metastases. It considers existing international guidelines and details them where appropriate. The main recommendations are: Patients with solid tumors except germ cell tumors and small-cell lung cancer with a life expectancy of more than 3 months suffering from a single brain metastasis of less than 3 cm in diameter should be considered for SRS. Especially when metastases are not amenable to surgery, are located in the brain stem, and have no mass effect, SRS should be offered to the patient. For multiple (two to four) metastases - all less than 2.5 cm in diameter - in patients with a life expectancy of more than 3 months, SRS should be used rather than whole-brain radiotherapy (WBRT). Adjuvant WBRT after SRS for both single and multiple (two to four) metastases increases local control and reduces the frequency of distant brain metastases, but does not prolong survival when compared with SRS and salvage treatment. As WBRT carries the risk of inducing neurocognitive damage, it seems reasonable to withhold WBRT for as long as possible. A single (marginal) dose of 20 Gy is a reasonable choice that balances the effect on the treated lesion (local control, partial remission) against the risk of late side effects (radionecrosis). Higher doses (22-25 Gy) may be used for smaller ( [de

  11. Image-guided stereotactic radiotherapy for patients with vestibular schwannoma. A clinical study

    Energy Technology Data Exchange (ETDEWEB)

    Badakhshi, H.; Muellner, S.; Budach, V. [Charite School of Medicine and University Hospital of Berlin, Departments for Radiation Oncology, Berlin (Germany); Wiener, E. [School of Medicine and University Hospital of Berlin, Institute for Neuroradiology, Berlin (Germany)

    2014-06-15

    Local tumor control and functional outcome after linac-based stereotactic radiosurgery (SRS) and fractionated stereotactic radiotherapy (FSRT) for vestibular schwannoma (VS) were assessed. In all, 250 patients with VS were treated: 190 patients with tumors < 2 cm diameter underwent SRS and 60 patients with tumors >2 to 3.5 cm underwent FSRT. Dose prescription for all cases with SRS (n = 190, 76 %) was 13.5 Gy. For FSRT, mainly two hypofractionated schedules (n = 60, 24 %) with either 7 fractions of 5 Gy (total dose: 35 Gy; n = 35) or 11 fractions of 3.8 Gy (total dose: 41.8 Gy; n = 16) were used. The primary endpoint was local tumor control. Secondary endpoints were symptomatic control and morbidity. The median follow-up was 33.8 months. The 3-year local tumor control was 88.9 %. Local control for SRS and FSRT was 88 and 92 %, respectively. For FSRT with 35 and 41.8 Gy, local control was 90 and 100 %, respectively. There were no acute reactions exceeding grade I. In 61 cases (24.4 % of the entire cohort), trigeminal neuralgia was reported prior to treatment. At last follow-up, 16.3 % (10/61) of those patients reported relief of pain. Regarding facial nerve dysfunction, 45 patients (18 %) presented with symptoms prior to RT. At the last follow-up, 13.3% (6/45) of those patients reported a relief of dysesthesia. Using SRS to treat small VS results in good local control rates. FSRT for larger lesions also seems effective. Severe treatment-related complications are not frequent. Therefore, image-guided stereotactic radiotherapy is an appropriate alternative to microsurgery for patients with VS. (orig.) [German] Wir analysierten die lokale Kontrolle und die funktionellen Verlaeufe bei Patienten mit einem Vestibularisschwannom (VS), die sich einer linacbasierten stereotaktischen Radiochirurgie (SRS) oder einer fraktionierten stereotaktischen Radiotherapie (FSRT) unterzogen. Zwischen 1998 und 2008 wurden 250 Patienten mit einem VS behandelt. In dieser Kohorte wurden 190

  12. Dosimetry for synchrotron stereotactic radiotherapy: from a macroscopic approach to microscopic energy deposits consideration

    International Nuclear Information System (INIS)

    Edouard, M.

    2010-01-01

    Numerous therapeutic strategies are currently being evaluated to find a curative treatment for high grade glioma. Among them, radiation therapy is partially effective but limited by the insufficient differential effect that can be reached between the dose delivered to the tumor compared to the one received by the healthy tissues. Synchrotron stereotactic radiotherapy aims at increasing this differential effect with a localized dose boost obtained by low energy x-rays stereotactic irradiations (≤ 100 keV) in presence of heavy elements restricted to the target area. This PhD work takes place in the general context of the future clinical trials foreseen at the European Synchrotron Radiation Facility. The first objective was to optimize the dose delivery to the target, at a macroscopic scale. We have demonstrated in particular that an even number of weighted beams was required to homogenize the tumor dose distribution. Microdosimetry studies were then performed to evaluate the dose delivered at the cellular level, taking into account the fine high-Z element distribution. These theoretical results have been compared to in vitro studies. Cell survival studies were performed using either a 3D glioma model (spheroids) or cells irradiated in suspension in an iodinated medium. (author) [fr

  13. Stereotactic radiotherapy of vestibular schwannoma. Hearing preservation, vestibular function, and local control following primary and salvage radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Putz, Florian; Mueller, Jan; Wimmer, Caterina; Goerig, Nicole; Knippen, Stefan; Semrau, Sabine; Fietkau, Rainer; Lettmaier, Sebastian [Friedrich-Alexander-University Erlangen-Nuremberg, Department of Radiation Oncology, Erlangen (Germany); Iro, Heinrich; Grundtner, Philipp [Friedrich-Alexander-University Erlangen-Nuremberg, Department of Otorhinolaryngology - Head and Neck Surgery, Erlangen (Germany); Eyuepoglu, Ilker; Roessler, Karl [Friedrich-Alexander-University Erlangen-Nuremberg, Department of Neurosurgery, Erlangen (Germany)

    2017-03-15

    The aim of this publication is to present long-term data on functional outcomes and tumor control in a cohort of 107 patients treated with stereotactic radiotherapy (RT) for vestibular schwannoma. Included were 107 patients with vestibular schwannoma (primary or recurrent following resection) treated with stereotactic RT (either fractioned or single-dose radiosurgery) between October 2002 and December 2013. Local control and functional outcomes were determined. Analysis of hearing preservation was limited to a subgroup of patients with complete audiometric data collected before treatment and during follow-up. Vestibular function test (FVT) results could be analyzed in a subset of patients and were compared to patient-reported dizziness. After a mean follow-up of 46.3 months, actuarial local control for the whole cohort was 100% after 2, 97.6% after 5, and 94.1% after 10 years. In patients with primary RT, serviceable hearing was preserved in 72%. Predictors for preservation of serviceable hearing in multivariate analysis were time of follow-up (odds ratio, OR = 0.93 per month; p = 0.021) and pre-RT tumor size (Koos stage I-IIa vs. IIb-IV; OR = 0.15; p = 0.031). Worsening of FVT results was recorded in 17.6% (N = 3). Profound discrepancy of patient-reported dizziness and FVT results was observed after RT. In patients with primary RT, worsening of facial nerve function occurred in 1.7% (N = 1). Stereotactic RT of vestibular schwannoma provides good functional outcomes and high control rates. Dependence of hearing preservation on time of follow-up and initial tumor stage has to be considered. (orig.) [German] Praesentation von Langzeitdaten zu funktionellen Ergebnissen und Tumorkontrolle nach stereotaktischer Radiotherapie (RT) in einer Kohorte von 107 Patienten mit Akustikusneurinom. Zwischen Oktober 2002 und Dezember 2013 wurden 107 Patienten mit Akustikusneurinom (primaer oder rezidiviert nach vorangegangener Resektion) mittels stereotaktischer RT behandelt

  14. Stereotactic irradiation for metastatic brain tumor

    International Nuclear Information System (INIS)

    Nomura, Ryutaro

    2017-01-01

    First, this paper reviewed the latest findings of stereotactic irradiation (STI) for metastatic brain tumors. Then, it described the results of randomized controlled trials for single or a few (2-4) metastasis in the following comparison tests: (1) comparison between whole brain radiotherapy (WBRT) alone group and (WBRT + STI) group, (2) comparison between STI alone group and (STI + WBRT) group, (3) comparison between STI alone group and (tumorectomy + WBRT) group, (4) comparison between (STI + WBRT) group and (tumorectomy + WBRT) group, and (5) between (tumorectomy + WBRT) group and (tumorectomy + STI) group. Among these, STI alone without WBRT has obtained a certain consensus. Against multiple metastatic brain tumors of 5 or more, when considering cognitive impairment and QOL loss by adding WBRT, it is general consensus that STI alone may be sufficient. At the authors' institution, cyber knife (CK) was introduced in 2008 and nearly 300 stereotactic radiotherapy for metastatic brain tumors have been performed annually. By adopting a robot arm and development of a lesion tracking system, the positional correction against the deviation of the bone margin of the skull is guaranteed in real time to ensure accuracy during irradiation, and hypofractionated stereotactic irradiation becomes easier. (A.O.)

  15. Treatment of Early Stage Non-Small Cell Lung Cancer: Surgery or Stereotactic Ablative Radiotherapy?

    Directory of Open Access Journals (Sweden)

    Esengül Koçak Uzel

    2015-03-01

    Full Text Available The management of early-stage Non-small Cell Lung Cancer (NSCLC has improved recently due to advances in surgical and radiation modalities. Minimally-invasive procedures like Video-assisted thoracoscopic surgery (VATS lobectomy decreases the morbidity of surgery, while the numerous methods of staging the mediastinum such as endobronchial and endoscopic ultrasound-guided biopsies are helping to achieve the objectives much more effectively. Stereotactic Ablative Radiotherapy (SABR has become the frontrunner as the standard of care in medically inoperable early stage NSCLC patients, and has also been branded as tolerable and highly effective. Ongoing researches using SABR are continuously validating the optimal dosing and fractionation schemes, while at the same time instituting its role for both inoperable and operable patients.

  16. Hypofractionated stereotactic radiotherapy in five daily fractions for post-operative surgical cavities in brain metastases patients with and without prior whole brain radiation.

    Science.gov (United States)

    Al-Omair, Ameen; Soliman, Hany; Xu, Wei; Karotki, Aliaksandr; Mainprize, Todd; Phan, Nicolas; Das, Sunit; Keith, Julia; Yeung, Robert; Perry, James; Tsao, May; Sahgal, Arjun

    2013-12-01

    Our purpose was to report efficacy of hypofractionated cavity stereotactic radiotherapy (HCSRT) in patients with and without prior whole brain radiotherapy (WBRT). 32 surgical cavities in 30 patients (20 patients/21 cavities had no prior WBRT and 10 patients/11 cavities had prior WBRT) were treated with image-guided linac stereotactic radiotherapy. 7 of the 10 prior WBRT patients had "resistant" local disease given prior surgery, post-operative WBRT and a re-operation, followed by salvage HCSRT. The clinical target volume was the post-surgical cavity, and a 2-mm margin applied as planning target volume. The median total dose was 30 Gy (range: 25-37.5 Gy) in 5 fractions. In the no prior and prior WBRT cohorts, the median follow-up was 9.7 months (range: 3.0-23.6) and 15.3 months (range: 2.9-39.7), the median survival was 23.6 months and 39.7 months, and the 1-year cavity local recurrence progression- free survival (LRFS) was 79 and 100%, respectively. At 18 months the LRFS dropped to 29% in the prior WBRT cohort. Grade 3 radiation necrosis occurred in 3 prior WBRT patients. We report favorable outcomes with HCSRT, and well selected patients with prior WBRT and "resistant" disease may have an extended survival favoring aggressive salvage HCSRT at a moderate risk of radiation necrosis.

  17. Polymer gel dosimetry for synchrotron stereotactic radiotherapy and iodine dose-enhancement measurements

    International Nuclear Information System (INIS)

    Boudou, C; Tropres, I; Rousseau, J; Lamalle, L; Adam, J F; Esteve, F; Elleaume, H

    2007-01-01

    Synchrotron stereotactic radiotherapy (SSR) is a radiotherapy technique that makes use of the interactions of monochromatic low energy x-rays with high atomic number (Z) elements. An important dose-enhancement can be obtained if the target volume has been loaded with a sufficient amount of a high-Z element, such as iodine. In this study, we compare experimental dose measurements, obtained with normoxic polymer gel (nPAG), with Monte Carlo computations. Gels were irradiated within an anthropomorphic head phantom and were read out by magnetic resonance imaging. The dose-enhancement due to the presence of iodine in the gel (iodine concentration: 5 and 10 mg ml -1 ) was measured at two radiation energies (35 and 80 keV) and was compared to the calculated factors. nPAG dosimetry was shown to be efficient for measuring the sharp dose gradients produced by SSR. The agreement between 3D gel dosimetry and calculated dose distributions was found to be within 4% of the dose difference criterion and a distance to agreement of 2.1 mm for 80% of the voxels. Polymer gel doped with iodine exhibited higher sensitivity, in good agreement with the calculated iodine-dose enhancement. We demonstrate in this preliminary study that iodine-doped nPAG could be used for measuring in situ dose distributions for iodine-enhanced SSR treatment

  18. Doses to organs at cerebral risks: optimization by robotized stereotaxic radiotherapy and automatic segmentation atlas versus three dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Bondiau, P.Y.; Thariat, J.; Benezery, K.; Herault, J.; Dalmasso, C.; Marcie, S.; Malandain, G.

    2007-01-01

    The stereotaxic radiotherapy robotized by 'Cyberknife fourth generation' allows a dosimetric optimization with a high conformity index on the tumor and radiation doses limited on organs at risk. A cerebral automatic anatomic segmentation atlas of organs at risk are used in routine in three dimensions. This study evaluated the superiority of the stereotaxic radiotherapy in comparison with the three dimensional conformal radiotherapy on the preservation of organs at risk in regard of the delivered dose to tumors justifying an accelerated hypo fractionation and a dose escalation. This automatic segmentation atlas should allow to establish correlations between anatomy and cerebral dosimetry; This atlas allows to underline the dosimetry optimization by stereotaxic radiotherapy robotized for organs at risk. (N.C.)

  19. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Directory of Open Access Journals (Sweden)

    Saito Ryo

    2011-10-01

    Full Text Available Abstract Background Chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT, appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%. Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months. Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%, of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present.

  20. Rib fracture after stereotactic radiotherapy on follow-up thin-section computed tomography in 177 primary lung cancer patients

    Science.gov (United States)

    2011-01-01

    Background Chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer has recently been reported. However, its detailed imaging findings are not clarified. So this study aimed to fully characterize the findings on computed tomography (CT), appearance time and frequency of chest wall injury after stereotactic radiotherapy (SRT) for primary lung cancer Materials and methods A total of 177 patients who had undergone SRT were prospectively evaluated for periodical follow-up thin-section CT with special attention to chest wall injury. The time at which CT findings of chest wall injury appeared was assessed. Related clinical symptoms were also evaluated. Results Rib fracture was identified on follow-up CT in 41 patients (23.2%). Rib fractures appeared at a mean of 21.2 months after the completion of SRT (range, 4 -58 months). Chest wall edema, thinning of the cortex and osteosclerosis were findings frequently associated with, and tending to precede rib fractures. No patients with rib fracture showed tumors > 16 mm from the adjacent chest wall. Chest wall pain was seen in 18 of 177 patients (10.2%), of whom 14 patients developed rib fracture. No patients complained of Grade 3 or more symptoms. Conclusion Rib fracture is frequently seen after SRT for lung cancer on CT, and is often associated with chest wall edema, thinning of the cortex and osteosclerosis. However, related chest wall pain is less frequent and is generally mild if present. PMID:21995807

  1. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy.

    Science.gov (United States)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-02-27

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  2. Accelerated partial breast irradiation using robotic radiotherapy: a dosimetric comparison with tomotherapy and three-dimensional conformal radiotherapy

    International Nuclear Information System (INIS)

    Rault, Erwann; Lacornerie, Thomas; Dang, Hong-Phuong; Crop, Frederik; Lartigau, Eric; Reynaert, Nick; Pasquier, David

    2016-01-01

    Accelerated partial breast irradiation (APBI) is a new breast treatment modality aiming to reduce treatment time using hypo fractionation. Compared to conventional whole breast irradiation that takes 5 to 6 weeks, APBI is reported to induce worse cosmetic outcomes both when using three-dimensional conformal radiotherapy (3D-CRT) and intensity-modulated radiotherapy (IMRT). These late normal tissue effects may be attributed to the dose volume effect because a large portion of the non-target breast tissue volume (NTBTV) receives a high dose. In the context of APBI, non-coplanar beams could spare the NTBTV more efficiently. This study evaluates the dosimetric benefit of using the Cyberknife (CK) for APBI in comparison to IMRT (Tomotherapy) and three dimensional conformal radiotherapy (3D-CRT). The possibility of using surgical clips, implanted during surgery, to track target movements is investigated first. A phantom of a female thorax was designed in-house using the measurements of 20 patients. Surgical clips of different sizes were inserted inside the breast. A treatment plan was delivered to the mobile and immobile phantom. The motion compensation accuracy was evaluated using three radiochromic films inserted inside the breast. Three dimensional conformal radiotherapy (3D-CRT), Tomotherapy (TOMO) and CK treatment plans were calculated for 10 consecutive patients who received APBI in Lille. To ensure a fair comparison of the three techniques, margins applied to the CTV were set to 10 mm. However, a second CK plan was prepared using 3 mm margins to evaluate the benefits of motion compensation. Only the larger clips (VITALITEC Medium-Large) could be tracked inside the larger breast (all gamma indices below 1 for 1 % of the maximum dose and 1 mm). All techniques meet the guidelines defined in the NSABP/RTOG and SHARE protocols. As the applied dose volume constraints are very strong, insignificant dosimetric differences exist between techniques regarding the PTV

  3. Adaptive fractionated stereotactic Gamma Knife radiotherapy of meningioma using integrated stereotactic cone-beam-CT and adaptive re-planning (a-gkFSRT).

    Science.gov (United States)

    Stieler, F; Wenz, F; Abo-Madyan, Y; Schweizer, B; Polednik, M; Herskind, C; Giordano, F A; Mai, S

    2016-11-01

    The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49°/0.18 ± 0.20°/0.05 ± 0.36° and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT.

  4. Effect of stereotactic body radiotherapy versus intensity-modulated radiotherapy in primary liver cancer patients with secondary malignant tumor of vertebra

    Directory of Open Access Journals (Sweden)

    SUN Jing

    2016-06-01

    Full Text Available ObjectiveTo investigate the effect of stereotactic body radiotherapy (SBRT versus intensity-modulated radiotherapy (IMRT in primary liver cancer (PLC patients with secondary malignant tumor of vertebra. MethodsA total of 49 PLC patients with secondary metastatic tumor of vertebra, who were treated in our hospital from December 2011 to January 2014, were enrolled and divided into group A (20 patients treated with SBRT and group B (29 patients treated with IMRT. The prescribed dose was 35 Gy in 5 fractions in group A and 35 Gy in 10 fractions in group B. The time to pain relief, imaging findings, and survival analysis were used to evaluate pain-relieving effect, the condition of lesions, and survival time. The t-test was used to compare continuous data between groups, and the chi-square test was used to compare categorical data between groups. The K-M method was used to plot survival curves for both groups, and the log-rank test was used for survival difference analysis. ResultsThe proportion of patients who achieved complete or partial remission and stable disease shown by radiological examination after radiotherapy showed no significant difference between group A and group B (P=0.873. The pain relief rate also showed no significant difference between group A and group B (P=0.908. The time of pain relief showed a significant difference between group A and group B (t=-3.353, P<0.01. The overall survival showed no significant difference between the two groups (P=0.346. ConclusionRadiotherapy has a definite therapeutic effect in PLC patients with secondary malignant tumor of vertebra. SBRT and IMRT have similar pain-relieving effects. However, with the same prescribed dose, SBRT has a short time to pain relief and does not lead to serious intolerable acute or late toxic and side effects in surrounding fast-response tissues.

  5. Maximizing Benefits from Maintenance Pemetrexed with Stereotactic Ablative Radiotherapy in Oligoprogressive Non-Squamous Non-Small Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Shao-Lun Lu

    2016-08-01

    Full Text Available Maintenance pemetrexed offers survival benefit with well-tolerated toxicities for advanced non-squamous non-small cell lung cancer (NSCLC. We present 3 consecutively enrolled patients with advanced non-squamous NSCLC, receiving stereotactic ablative radiotherapy (SABR for oligoprogressive disease during maintenance pemetrexed. All of them had sustained local control of thoracic oligoprogression after the SABR, while maintenance pemetrexed were kept for additionally long progression-free interval. SABR targeting oligoprogression with continued pemetrexed is an effective and safe approach to extend exposure of maintenance pemetrexed, thus maximizing the benefit from it.

  6. Stereotactic Body Radiotherapy Reirradiation for Recurrent Epidural Spinal Metastases

    International Nuclear Information System (INIS)

    Mahadevan, Anand; Floyd, Scott; Wong, Eric; Jeyapalan, Suriya; Groff, Michael; Kasper, Ekkehard

    2011-01-01

    Purpose: When patients show progression after conventional fractionated radiation for spine metastasis, further radiation and surgery may not be options. Stereotactic body radiotherapy (SBRT) has been successfully used in treatment of the spine and may be applicable in these cases. We report the use of SBRT for 60 consecutive patients (81 lesions) who had radiological progressive spine metastasis with epidural involvement after previous radiation for spine metastasis. Methods and Materials: SBRT was used with fiducial and vertebral anatomy-based targeting. The radiation dose was prescribed based on the extent of spinal canal involvement; the dose was 8 Gy × 3 = 24 Gy when the tumor did not touch the spinal cord and 5 to 6 Gy x 5 = 25 to 30 Gy when the tumor abutted the cord. The cord surface received up to the prescription dose with no hot spots in the cord. Results: The median overall survival was 11 months, and the median progression-free survival was 9 months. Overall, 93% of patients had stable or improved disease while 7% of patients showed disease progression; 65% of patients had pain relief. There was no significant toxicity other than fatigue. Conclusions: SBRT is feasible and appears to be an effective treatment modality for reirradiation after conventional palliative radiation fails for spine metastasis patients.

  7. Stereotactic Body Radiotherapy Reirradiation for Recurrent Epidural Spinal Metastases

    Energy Technology Data Exchange (ETDEWEB)

    Mahadevan, Anand, E-mail: amahadev@bidmc.harvard.edu [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts and Harvard Medical School (Israel); Floyd, Scott [Department of Radiation Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts and Harvard Medical School (Israel); Wong, Eric; Jeyapalan, Suriya [Department of Neuro-Oncology, Beth Israel Deaconess Medical Center, Boston, Massachusetts and Harvard Medical School (Israel); Groff, Michael; Kasper, Ekkehard [Department of Neurosurgery, Beth Israel Deaconess Medical Center, Boston, Massachusetts and Harvard Medical School (Israel)

    2011-12-01

    Purpose: When patients show progression after conventional fractionated radiation for spine metastasis, further radiation and surgery may not be options. Stereotactic body radiotherapy (SBRT) has been successfully used in treatment of the spine and may be applicable in these cases. We report the use of SBRT for 60 consecutive patients (81 lesions) who had radiological progressive spine metastasis with epidural involvement after previous radiation for spine metastasis. Methods and Materials: SBRT was used with fiducial and vertebral anatomy-based targeting. The radiation dose was prescribed based on the extent of spinal canal involvement; the dose was 8 Gy Multiplication-Sign 3 = 24 Gy when the tumor did not touch the spinal cord and 5 to 6 Gy x 5 = 25 to 30 Gy when the tumor abutted the cord. The cord surface received up to the prescription dose with no hot spots in the cord. Results: The median overall survival was 11 months, and the median progression-free survival was 9 months. Overall, 93% of patients had stable or improved disease while 7% of patients showed disease progression; 65% of patients had pain relief. There was no significant toxicity other than fatigue. Conclusions: SBRT is feasible and appears to be an effective treatment modality for reirradiation after conventional palliative radiation fails for spine metastasis patients.

  8. Stereotactic body radiotherapy reirradiation for recurrent epidural spinal metastases.

    Science.gov (United States)

    Mahadevan, Anand; Floyd, Scott; Wong, Eric; Jeyapalan, Suriya; Groff, Michael; Kasper, Ekkehard

    2011-12-01

    When patients show progression after conventional fractionated radiation for spine metastasis, further radiation and surgery may not be options. Stereotactic body radiotherapy (SBRT) has been successfully used in treatment of the spine and may be applicable in these cases. We report the use of SBRT for 60 consecutive patients (81 lesions) who had radiological progressive spine metastasis with epidural involvement after previous radiation for spine metastasis. SBRT was used with fiducial and vertebral anatomy-based targeting. The radiation dose was prescribed based on the extent of spinal canal involvement; the dose was 8 Gy×3=24 Gy when the tumor did not touch the spinal cord and 5 to 6 Gyx5=25 to 30 Gy when the tumor abutted the cord. The cord surface received up to the prescription dose with no hot spots in the cord. The median overall survival was 11 months, and the median progression-free survival was 9 months. Overall, 93% of patients had stable or improved disease while 7% of patients showed disease progression; 65% of patients had pain relief. There was no significant toxicity other than fatigue. SBRT is feasible and appears to be an effective treatment modality for reirradiation after conventional palliative radiation fails for spine metastasis patients. Copyright © 2011 Elsevier Inc. All rights reserved.

  9. Stereotactic body radiotherapy for localized prostate cancer: disease control and quality of life at 6 years

    International Nuclear Information System (INIS)

    Katz, Alan J; Santoro, Michael; Diblasio, Fred; Ashley, Richard

    2013-01-01

    Stereotactic body radiotherapy (SBRT) may yield disease control for prostate cancer in a brief, hypofractionated treatment regimen without increasing treatment toxicity. Our report presents a 6-year update from 304 low- (n = 211), intermediate- (n = 81), and high-risk (n = 12) prostate cancer patients who received CyberKnife SBRT. The median PSA at presentation was 5.8 ng/ml. Fifty-seven patients received neoadjuvant hormonal therapy for up to one year. The first 50 patients received a total dose of 35 Gy in 5 fractions of 7 Gy. The subsequent 254 patients received a total dose of 36.25 Gy in 5 fractions of 7.25 Gy. Toxicity was assessed with the Expanded Prostate Cancer Index Composite questionnaire and the Radiation Therapy Oncology Group urinary and rectal toxicity scale. Biochemical failure was assessed using the nadir + 2 definition. No patients experienced Grade III or IV acute complications. Fewer than 5% of patients experienced any acute Grade II urinary or rectal toxicities. Late urinary Grade II complications were observed in 4% of patients treated to 35 Gy and 9% of patients treated to 36.25 Gy. Five (2%) late Grade III urinary toxicities occurred in patients who were treated with 36.25 Gy. Late Grade II rectal complications were observed in 2% of patients treated to 35 Gy and 5% of patients treated to 36.25 Gy. Bowel and urinary quality of life (QOL) scores initially decreased, but later returned to baseline values. An overall decrease of 20% in the sexual QOL score was observed. QOL in each domain was not differentially affected by dose. For patients that were potent prior to treatment, 75% stated that they remained sexually potent. Actuarial 5-year biochemical recurrence-free survival was 97% for low-risk, 90.7% for intermediate-risk, and 74.1% for high-risk patients. PSA fell to a median of 0.12 ng/ml at 5 years; dose did not influence median PSA levels. In this large series with long-term follow-up, we found excellent biochemical control rates and

  10. Proton-Based Stereotactic Ablative Radiotherapy in Early-Stage Non-Small-Cell Lung Cancer

    Directory of Open Access Journals (Sweden)

    Jonathan D. Grant

    2014-01-01

    Full Text Available Stereotactic ablative radiotherapy (SABR, a recent implementation in the practice of radiation oncology, has been shown to confer high rates of local control in the treatment of early stage non-small-cell lung cancer (NSCLC. This technique, which involves limited invasive procedures and reduced treatment intervals, offers definitive treatment for patients unable or unwilling to undergo an operation. The use of protons in SABR delivery confers the added physical advantage of normal tissue sparing due to the absence of collateral radiation dose delivered to regions distal to the target. This may translate into clinical benefit and a decreased risk of clinical toxicity in patients with nearby critical structures or limited pulmonary reserve. In this review, we present the rationale for proton-based SABR, principles relating to the delivery and planning of this modality, and a summary of published clinical studies.

  11. Prognostic indices in stereotactic radiotherapy of brain metastases of non-small cell lung cancer.

    Science.gov (United States)

    Kaul, David; Angelidis, Alexander; Budach, Volker; Ghadjar, Pirus; Kufeld, Markus; Badakhshi, Harun

    2015-11-26

    Our purpose was to analyze the long-term clinical outcome and to identify prognostic factors after Linac-based stereotactic radiosurgery (SRS) or fractionated stereotactic radiotherapy (FSRT) on patients with brain metastases (BM) from non-small cell lung cancer (NSCLC). We performed a retrospective analysis of survival on 90 patients who underwent SRS or FSRT of intracranial NSCLC metastases between 04/2004 and 05/2014 that had not undergone prior surgery or whole brain radiotherapy (WBRT) for BM. Follow-up data was analyzed until May 2015. Potential prognostic factors were examined in univariable and multivariable analyses. The Golden Grading System (GGS), the disease-specific graded prognostic assessment (DS-GPA), the RADES II prognostic index as well as the NSCLC-specific index proposed by Rades et al. in 2013 (NSCLC-RADES) were calculated and their predictive values were tested in univariable analysis. The median follow-up time of the surviving patients was 14 months. The overall survival (OS) rate was 51 % after 6 months and 29.9 % after 12 months. Statistically significant factors of better OS after univariable analysis were lower International Union Against Cancer (UICC) stage at first diagnosis, histology of adenocarcinoma, prior surgery of the primary tumor and lower total BM volume. After multivariable analysis adenocarcinoma histology remained a significant factor; higher Karnofsky Performance Score (KPS) and the presence of extracranial metastases (ECM) were also significant. The RADES II and the NSCLC-RADES indices were significant predictors of OS. However, the NSCLC-RADES failed to differentiate between intermediate- and low-risk patients. The DS-GPA and GGS were not statistically significant predictors of survival in univariable analysis. The ideal prognostic index has not been defined yet. We believe that more specific indices will be developed in the future. Our results indicate that the histologic subtype of NSCLC could add to the prognostic

  12. Fractionated stereotactic radiotherapy for acoustic neuromas: A prospective monocenter study of about 158 cases

    International Nuclear Information System (INIS)

    Litre, Fabien; Rousseaux, Pascal; Jovenin, Nicolas; Bazin, Arnaud; Peruzzi, Philippe; Wdowczyk, Didier; Colin, Philippe

    2013-01-01

    Purpose: To evaluate long-term outcomes and efficacy of fractionated stereotactic radiotherapy in the treatment of acoustic neuromas. Material and methods: Between January 1996 and December 2009, 158 acoustic neuromas were treated by FSR in 155 patients. They received a dose of 50.4 Gy, with a safety margin of 1–2 mm with a median tumor volume at 2.45 mL (range: 0.17–12.5 mL) and a median follow-up duration at 60 months (range: 24–192). Results: FSR was well tolerated in all patients with mild sequelae consisting in radiation-induced trigeminal nerve impairments (3.2%), Grade 2 facial neuropathies (2.5%), new or aggravated tinnitus (2.1%) and VP shunting (2.5%). The treatment failed in four patients (2.5%) who had subsequent surgery respectively at 20, 38, 45 and 84 months post-FSR. The local tumor control rates were respectively 99.3%, 97.5% and 95.2% at 3, 5 and >7-year of follow-up. For initial Gardner–Robertson Grade 1 and 2 ANs, the preservation of useful hearing was possible in 54% of the cases; only Grade 1 ANs had stabilized during the course of the follow-up with 71% >7 years. However, hearing preservation was not correlated to the initial Koos Stage and to the radiation dose delivered to the cochlea. Tinnitus (70%), vertigo (59%), imbalance (46%) and ear mastoid pain (43%) had greatly improved post-FRS in most patients. Tumor control, hearing preservation and FRS toxicity were quite similar in patients with NF2, cystic acoustic neuroma, prior surgical resection and Koos Stage 4 AN. No secondary tumors were observed. Conclusion: FSR is a safe and effective therapeutic for acoustic neuromas and could be an alternative to microsurgery. Compared to radiosurgery, there are no contraindications for fractioned doses of stereotactic radiotherapy especially for Stage-4 tumors and patients at high risk of hearing loss

  13. Fractionated stereotactic radiotherapy for acoustic neuromas: A prospective monocenter study of about 158 cases

    Energy Technology Data Exchange (ETDEWEB)

    Litre, Fabien [Hôpital Maison Blanche, Reims Cedex (France); Rousseaux, Pascal [Hôpital Maison Blanche, Reims Cedex (France); Jovenin, Nicolas [Institut Jean Godinot, Reims Cedex (France); Bazin, Arnaud; Peruzzi, Philippe [Hôpital Maison Blanche, Reims Cedex (France); Wdowczyk, Didier; Colin, Philippe [Institut du Cancer Reims Courlancy, Reims (France)

    2013-02-15

    Purpose: To evaluate long-term outcomes and efficacy of fractionated stereotactic radiotherapy in the treatment of acoustic neuromas. Material and methods: Between January 1996 and December 2009, 158 acoustic neuromas were treated by FSR in 155 patients. They received a dose of 50.4 Gy, with a safety margin of 1–2 mm with a median tumor volume at 2.45 mL (range: 0.17–12.5 mL) and a median follow-up duration at 60 months (range: 24–192). Results: FSR was well tolerated in all patients with mild sequelae consisting in radiation-induced trigeminal nerve impairments (3.2%), Grade 2 facial neuropathies (2.5%), new or aggravated tinnitus (2.1%) and VP shunting (2.5%). The treatment failed in four patients (2.5%) who had subsequent surgery respectively at 20, 38, 45 and 84 months post-FSR. The local tumor control rates were respectively 99.3%, 97.5% and 95.2% at 3, 5 and >7-year of follow-up. For initial Gardner–Robertson Grade 1 and 2 ANs, the preservation of useful hearing was possible in 54% of the cases; only Grade 1 ANs had stabilized during the course of the follow-up with 71% >7 years. However, hearing preservation was not correlated to the initial Koos Stage and to the radiation dose delivered to the cochlea. Tinnitus (70%), vertigo (59%), imbalance (46%) and ear mastoid pain (43%) had greatly improved post-FRS in most patients. Tumor control, hearing preservation and FRS toxicity were quite similar in patients with NF2, cystic acoustic neuroma, prior surgical resection and Koos Stage 4 AN. No secondary tumors were observed. Conclusion: FSR is a safe and effective therapeutic for acoustic neuromas and could be an alternative to microsurgery. Compared to radiosurgery, there are no contraindications for fractioned doses of stereotactic radiotherapy especially for Stage-4 tumors and patients at high risk of hearing loss.

  14. Role of stereotactic body radiotherapy for oligometastasis from colorectal cancer.

    Science.gov (United States)

    Takeda, Atsuya; Sanuki, Naoko; Kunieda, Etsuo

    2014-04-21

    Systemic chemotherapy has enabled prolongation of survival in patients with stage IV colorectal cancer. This has subsequently increased the relative significance of local therapy for patients with oligometastases because they can be cured by removal of oligometastatic lesions. One of the most frequently reported tumor histologies for oligometastases is colorectal cancer. Resection is the standard therapy in most settings of oligometastases. Recently, studies have shown that stereotactic body radiotherapy (SBRT) may become a treatment option that provides high local control with minimal morbidity. Two-year local control rates following SBRT for hepatic and pulmonary oligometastases are almost over 80% and are even higher for patients treated with high-dose regimens. The indications of SBRT for other metastatic sites or conditions include isolated lymph nodes, spinal and adrenal metastasis, and post-surgical pelvic recurrence. Many retrospective studies have indicated that SBRT for various lesions results in good outcomes with low morbidity, both in the curative and palliative setting. However, few reports with a high level of evidence have indicated the efficacy of SBRT compared to standard therapy. Hereafter, the optimal indication of SBRT needs to be prospectively investigated to obtain convincing evidence.

  15. Long term results after fractionated stereotactic radiotherapy (FSRT) in patients with craniopharyngioma: maximal tumor control with minimal side effects

    International Nuclear Information System (INIS)

    Harrabi, Semi B; Adeberg, Sebastian; Welzel, Thomas; Rieken, Stefan; Habermehl, Daniel; Debus, Jürgen; Combs, Stephanie E

    2014-01-01

    There are already numerous reports about high local control rates in patients with craniopharyngioma but there are only few studies with follow up times of more than 10 years. This study is an analysis of long term control, tumor response and side effects after fractionated stereotactic radiotherapy (FSRT) for patients with craniopharyngioma. 55 patients who were treated with FSRT for craniopharyngioma were analyzed. Median age was 37 years (range 6–70 years), among them eight children < 18 years. Radiotherapy (RT) was indicated for progressive disease after neurosurgical resection or postoperatively after repeated resection or partial resection. A median dose of 52.2 Gy (50 – 57.6 Gy) was applied with typical dose per fraction of 1.8 Gy five times per week. The regular follow up examinations comprised in addition to contrast enhanced MRI scans thorough physical examinations and clinical evaluation. During median follow up of 128 months (2 – 276 months) local control rate was 95.3% after 5 years, 92.1% after 10 years and 88.1% after 20 years. Overall survival after 10 years was 83.3% and after 20 years 67.8% whereby none of the deaths were directly attributed to craniopharyngioma. Overall treatment was tolerated well with almost no severe acute or chronic side effects. One patient developed complete anosmia, another one’s initially impaired vision deteriorated further. In 83.6% of the cases with radiological follow up a regression of irradiated tumor residues was monitored, in 7 cases complete response was achieved. 44 patients presented themselves initially with endocrinologic dysfunction none of them showed signs of further deterioration during follow up. No secondary malignancies were observed. Long term results for patients with craniopharyngioma after stereotactic radiotherapy are with respect to low treatment related side effects as well as to local control and overall survival excellent

  16. EF5 PET of Tumor Hypoxia: A Predictive Imaging Biomarker of Response to Stereotactic Ablative Radiotherapy (SABR) for Early Lung Cancer

    Science.gov (United States)

    2017-11-01

    SABR) for Early Lung Cancer PRINCIPAL INVESTIGATOR: Billy W Loo Jr, MD PhD CONTRACTING ORGANIZATION: The Leland Stanford Junior University...Response to Stereotactic Ablative Radiotherapy (SABR) for Early Lung Cancer 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Billy W Loo Jr, MD...for early stage lung cancer in patients who are not candidates for surgery because of excessive surgical risk, and will be an important treatment option

  17. Predictors of Radiotherapy Induced Bone Injury (RIBI) after stereotactic lung radiotherapy

    International Nuclear Information System (INIS)

    Taremi, Mojgan; Hope, Andrew; Lindsay, Patricia; Dahele, Max; Fung, Sharon; Purdie, Thomas G; Jaffray, David; Dawson, Laura; Bezjak, Andrea

    2012-01-01

    The purpose of this study was to identify clinical and dosimetric factors associated with radiotherapy induced bone injury (RIBI) following stereotactic lung radiotherapy. Inoperable patients with early stage non-small cell lung cancer, treated with SBRT, who received 54 or 60 Gy in 3 fractions, and had a minimum of 6 months follow up were reviewed. Archived treatment plans were retrieved, ribs delineated individually and treatment plans re-computed using heterogeneity correction. Clinical and dosimetric factors were evaluated for their association with rib fracture using logistic regression analysis; a dose-event curve and nomogram were created. 46 consecutive patients treated between Oct 2004 and Dec 2008 with median follow-up 25 months (m) (range 6 – 51 m) were eligible. 41 fractured ribs were detected in 17 patients; median time to fracture was 21 m (range 7 – 40 m). The mean maximum point dose in non-fractured ribs (n = 1054) was 10.5 Gy ± 10.2 Gy, this was higher in fractured ribs (n = 41) 48.5 Gy ± 24.3 Gy (p < 0.0001). On univariate analysis, age, dose to 0.5 cc of the ribs (D 0.5 ), and the volume of the rib receiving at least 25 Gy (V 25 ), were significantly associated with RIBI. As D 0.5 and V 25 were cross-correlated (Spearman correlation coefficient: 0.57, p < 0.001), we selected D 0.5 as a representative dose parameter. On multivariate analysis, age (odds ratio: 1.121, 95% CI: 1.04 – 1.21, p = 0.003), female gender (odds ratio: 4.43, 95% CI: 1.68 – 11.68, p = 0.003), and rib D 0.5 (odds ratio: 1.0009, 95% CI: 1.0007 – 1.001, p < 0.0001) were significantly associated with rib fracture. Using D 0.5, a dose-event curve was constructed estimating risk of fracture from dose at the median follow up of 25 months after treatment. In our cohort, a 50% risk of rib fracture was associated with a D 0.5 of 60 Gy. Dosimetric and clinical factors contribute to risk of RIBI and both should be included when modeling risk of toxicity. A nomogram is

  18. Predictors of Radiotherapy Induced Bone Injury (RIBI after stereotactic lung radiotherapy

    Directory of Open Access Journals (Sweden)

    Taremi Mojgan

    2012-09-01

    Full Text Available Abstract Background The purpose of this study was to identify clinical and dosimetric factors associated with radiotherapy induced bone injury (RIBI following stereotactic lung radiotherapy. Methods Inoperable patients with early stage non-small cell lung cancer, treated with SBRT, who received 54 or 60 Gy in 3 fractions, and had a minimum of 6 months follow up were reviewed. Archived treatment plans were retrieved, ribs delineated individually and treatment plans re-computed using heterogeneity correction. Clinical and dosimetric factors were evaluated for their association with rib fracture using logistic regression analysis; a dose-event curve and nomogram were created. Results 46 consecutive patients treated between Oct 2004 and Dec 2008 with median follow-up 25 months (m (range 6 – 51 m were eligible. 41 fractured ribs were detected in 17 patients; median time to fracture was 21 m (range 7 – 40 m. The mean maximum point dose in non-fractured ribs (n = 1054 was 10.5 Gy ± 10.2 Gy, this was higher in fractured ribs (n = 41 48.5 Gy ± 24.3 Gy (p 0.5, and the volume of the rib receiving at least 25 Gy (V25, were significantly associated with RIBI. As D0.5 and V25 were cross-correlated (Spearman correlation coefficient: 0.57, p 0.5 as a representative dose parameter. On multivariate analysis, age (odds ratio: 1.121, 95% CI: 1.04 – 1.21, p = 0.003, female gender (odds ratio: 4.43, 95% CI: 1.68 – 11.68, p = 0.003, and rib D0.5 (odds ratio: 1.0009, 95% CI: 1.0007 – 1.001, p  Using D0.5, a dose-event curve was constructed estimating risk of fracture from dose at the median follow up of 25 months after treatment. In our cohort, a 50% risk of rib fracture was associated with a D0.5 of 60 Gy. Conclusions Dosimetric and clinical factors contribute to risk of RIBI and both should be included when modeling risk of toxicity. A nomogram is presented using D0.5, age, and female gender to

  19. Radiobiology of hypofractionated stereotactic radiotherapy: what are the optimal fractionation schedules?

    International Nuclear Information System (INIS)

    Shibamoto, Yuta; Miyakawa, Akifumi; Otsuka, Shinya; Iwata, Hiromitsu

    2016-01-01

    In hypofractionated stereotactic radiotherapy (SRT), high doses per fraction are usually used and the dose delivery pattern is different from that of conventional radiation. The daily dose is usually given intermittently over a longer time compared with conventional radiotherapy. During prolonged radiation delivery, sublethal damage repair takes place, leading to the decreased effect of radiation. In in vivo tumors, however, this decrease in effect may be counterbalanced by rapid reoxygenation. Another issue related to hypofractionated SRT is the mathematical model for dose evaluation and conversion. The linear–quadratic (LQ) model and biologically effective dose (BED) have been suggested to be incorrect when used for hypofractionation. The LQ model overestimates the effect of high fractional doses of radiation. BED is particularly incorrect when used for tumor responses in vivo, since it does not take reoxygenation into account. Correction of the errors, estimated at 5–20%, associated with the use of BED is necessary when it is used for SRT. High fractional doses have been reported to exhibit effects against tumor vasculature and enhance host immunity, leading to increased antitumor effects. This may be an interesting topic that should be further investigated. Radioresistance of hypoxic tumor cells is more problematic in hypofractionated SRT, so trials of hypoxia-targeted agents are encouraged in the future. In this review, the radiobiological characteristics of hypofractionated SRT are summarized, and based on the considerations, we would like to recommend 60 Gy in eight fractions delivered three times a week for lung tumors larger than 2 cm in diameter

  20. Phase-II study on stereotactic radiotherapy of locally advanced pancreatic carcinoma

    International Nuclear Information System (INIS)

    Hoyer, Morten; Roed, Henrik; Sengelov, Lisa; Traberg, Anders; Ohlhuis, Lars; Pedersen, Jorgen; Nellemann, Hanne; Kiil Berthelsen, Anne; Eberholst, Frey; Engelholm, Svend Aage; Maase, Hans von der

    2005-01-01

    Background and purpose: The majority of patients with pancreatic cancer have advanced disease at the time of diagnosis and are not amenable for surgery. Stereotactic radiotherapy (SRT) may be an alternative treatment for patients with locally advanced disease. The effect of SRT was investigated in the present phase-II trial. Patients and methods: Twenty-two patients with locally advanced and surgically non-resectable, histological proven pancreatic carcinoma were included into the trial. The patients were immobilized by the Elekta stereotactic body frame (SBF) or a custom made body frame. SRT was given on standard LINAC with standard multi-leaf collimator. Central dose was 15 Gyx3 within 5-10 days. Results: Evaluation of response was found to be very difficult due to radiation and tumour related tissue reaction. Only two patients (9%) were found to have a partial response (PR), the remaining had no change (NC) or progression (PD) after treatment. Six patients had local tumour progression, but only one patient had an isolated local failure without simultaneous distant metastasis. Median time to local or distant progression was 4.8 months. Median survival time was 5.7 months and only 5% were alive 1 year after treatment. Acute toxicity reported 14 days after treatment was pronounced. There was a significant deterioration of performance status (P=0.008), more nausea (P=0.001) and more pain (P=0.008) after 14 days compared with base-line. However, 8 of 12 patients (66%) improved in performance status, scored less nausea, pain, or needed less analgesic drugs at 3 months after treatment. Four patients suffered from severe mucositis or ulceration of the stomach or duodenum and one of the patients had a non-fatal ulcer perforation of the stomach. Conclusions: SRT was associated with poor outcome, unacceptable toxicity and questionable palliative effect and cannot be recommended for patients with advanced pancreatic carcinoma

  1. Target Coverage in Image-Guided Stereotactic Body Radiotherapy of Liver Tumors

    International Nuclear Information System (INIS)

    Wunderink, Wouter; Romero, Alejandra Mendez; Osorio, Eliana M. Vasquez; Boer, Hans C.J. de; Brandwijk, Rene P.; Levendag, Peter C.; Heijmen, Ben

    2007-01-01

    Purpose: To determine the effect of image-guided procedures (with computed tomography [CT] and electronic portal images before each treatment fraction) on target coverage in stereotactic body radiotherapy for liver patients using a stereotactic body frame (SBF) and abdominal compression. CT guidance was used to correct for day-to-day variations in the tumor's mean position in the SBF. Methods and Materials: By retrospectively evaluating 57 treatment sessions, tumor coverage, as obtained with the clinically applied CT-guided protocol, was compared with that of alternative procedures. The internal target volume-plus (ITV + ) was introduced to explicitly include uncertainties in tumor delineations resulting from CT-imaging artifacts caused by residual respiratory motion. Tumor coverage was defined as the volume overlap of the ITV + , derived from a tumor delineated in a treatment CT scan, and the planning target volume. Patient stability in the SBF, after acquisition of the treatment CT scan, was evaluated by measuring the displacement of the bony anatomy in the electronic portal images relative to CT. Results: Application of our clinical protocol (with setup corrections following from manual measurements of the distances between the contours of the planning target volume and the daily clinical target volume in three orthogonal planes, multiple two-dimensional) increased the frequency of nearly full (≥99%) ITV + coverage to 77% compared with 63% without setup correction. An automated three-dimensional method further improved the frequency to 96%. Patient displacements in the SBF were generally small (≤2 mm, 1 standard deviation), but large craniocaudal displacements (maximal 7.2 mm) were occasionally observed. Conclusion: Daily, CT-assisted patient setup may substantially improve tumor coverage, especially with the automated three-dimensional procedure. In the present treatment design, patient stability in the SBF should be verified with portal imaging

  2. Nomogram based overall survival prediction in stereotactic body radiotherapy for oligo-metastatic lung disease

    DEFF Research Database (Denmark)

    Tanadini-Lang, S; Rieber, J; Filippi, A R

    2017-01-01

    BACKGROUND: Radical local treatment of pulmonary metastases is practiced with increasing frequency due to acknowledgment and better understanding of oligo-metastatic disease. This study aimed to develop a nomogram predicting overall survival (OS) after stereotactic body radiotherapy (SBRT......) for pulmonary metastases. PATIENTS AND METHODS: A multi-institutional database of 670 patients treated with SBRT for pulmonary metastases was used as training cohort. Cox regression analysis with bidirectional variable elimination was performed to identify factors to be included into the nomogram model...... to predict 2-year OS. The calibration rate of the nomogram was assessed by plotting the actual Kaplan-Meier 2-year OS against the nomogram predicted survival. The nomogram was externally validated using two separate monocentric databases of 145 and 92 patients treated with SBRT for pulmonary metastases...

  3. Potential impact of 68Ga-DOTATOC PET/CT on stereotactic radiotherapy planning of meningiomas

    International Nuclear Information System (INIS)

    Nyuyki, Fonyuy; Plotkin, Michail; Michel, Roger; Steffen, Ingo; Fahdt, Daniel; Brenner, Winfried; Graf, Reinhold; Denecke, Timm; Geworski, Lilli; Wurm, Reinhard

    2010-01-01

    Since meningiomas show a high expression of somatostatin receptor subtype 2, PET with 68 Ga-DOTATOC was proposed as an additional imaging modality beside CT and MRI for planning radiotherapy. We investigated the input of 68 Ga-DOTATOC-PET/CT on the definition of the ''gross tumour volume'' (GTV) in meningiomas, in order to assess the potential value of this method. Prior to radiotherapy, 42 patients with meningiomas (26 f, 16 m, mean age 55) underwent MRI and 68 Ga-DOTATOC-PET/CT examinations. History: operated n = 24, radiotherapy n = 1, operation and radiotherapy n = 8, no treatment n = 9. PET/CT and MRI data were co-registered using a BrainLAB workstation. For comparison, the GTV was defined first under consideration of CT and MRI data, then using PET data. 3/42 patients were excluded from the analysis (two with negative PET results, one with an extensive tumour, not precisely delineable by MRI or PET/CT). The average GTV CT/MRI was 22(±19)cm 3 ; GTV PET was 23(±20)cm 3 . Additional GTV, obtained as a result of PET was 9(±10)cm 3 and was observed in patients with osseous infiltration. In some pre-treated patients there were intratumoural areas (as identified in CT/MRI) without SR-expression (7(±11)cm 3 ). Common GTV as obtained by both CT/MRI and PET was 15(±14)cm 3 . The mean bi-directional difference between the GTV CT/MRI and GTV PET accounted to 16(±15)cm 3 (93%, p 68 Ga-DOTATOC-PET enables delineation of SR-positive meningiomas and delivers additional information to both CT and MRI regarding the planning of stereotactic radiotherapy. The acquisition on a PET/CT scanner helps to estimate the relation of PET findings to anatomical structures and is especially useful for detection of osseous infiltration. 68 Ga-DOTATOC-PET also allows detection of additional lesions in patients with multiple meningiomas. (orig.)

  4. IMRT with Stereotactic Body Radiotherapy Boost for High Risk Malignant Salivary Gland Malignancies : A Case Series

    Directory of Open Access Journals (Sweden)

    Sana D Karam

    2014-10-01

    Full Text Available Patients with high risk salivary gland malignancies are at increased risk of local failure. We present our institutional experience with dose escalation using hypofractionated Stereotactic Body Radiotherapy (SBRT in a subset of this rare disease. Over the course of 9 years, 10 patients presenting with skull base invasion, gross disease with one or more adverse features, or those treated with adjuvant radiation with three or more pathologic features were treated with intensity modulated radiation therapy followed by hypofractionated SBRT boost. Patients presented with variable tumor histologies, and in all but one, the tumors were classified as poorly differentiated high grade. Four patients had gross disease, 3 had gross residual disease, 3 had skull base invasion, and 2 patients had rapidly recurrent disease (≤ 6 months that had been previously treated with surgical resection. The median Stereotactic Radiosurgery boost dose was 17.5 Gy (range 10-30 Gy given in a median of 5 fractions (range 3-6 fractions for a total median cumulative dose of 81.2 Gy (range 73.2-95.6 Gy. The majority of the patients received platinum based concurrent chemotherapy with their radiation. At a median follow-up of 32 months (range 12-120 for all patients and 43 months for surviving patients (range 12-120, actuarial 3-year locoregional control, distant control, progression free survival, and overall survival were 88%, 81%, 68%, and 79%, respectively. Only one patient failed locally and two failed distantly. Serious late toxicity included graft ulceration in 1 patient and osteoradionecrosis in another patient, both of which underwent surgical reconstruction. Six patients developed fibrosis. In a subset of patients with salivary gland malignancies with skull base invasion, gross disease, or those treated adjuvantly with three or more adverse pathologic features, hypofractionated SBRT boost to Intensity Modulated Radiotherapy yields good local control rates and

  5. CyberKnife with Tumor Tracking: An Effective Treatment for High-Risk Surgical Patients with Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Chen, Viola J.; Oermann, Eric [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Vahdat, Saloomeh [Department of Pathology, Georgetown University Hospital, Washington, DC (United States); Rabin, Jennifer; Suy, Simeng; Yu, Xia; Collins, Sean P. [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States); Subramaniam, Deepa [Division of Hematology and Oncology, Georgetown University Hospital, Washington, DC (United States); Banovac, Filip [Department of Radiology, Georgetown University Hospital, Washington, DC (United States); Anderson, Eric [Division of Pulmonary, Critical Care and Sleep Medicine, Georgetown University Hospital, Washington, DC (United States); Collins, Brian T., E-mail: collinsb@gunet.georgetown.edu [Department of Radiation Medicine, Georgetown University Hospital, Washington, DC (United States)

    2012-02-01

    Published data suggests that wedge resection for stage I non-small cell lung cancer (NSCLC) is associated with improved overall survival compared to stereotactic body radiation therapy. We report CyberKnife outcomes for high-risk surgical patients with biopsy-proven stage I NSCLC. PET/CT imaging was completed for staging. Three-to-five gold fiducial markers were implanted in or near tumors to serve as targeting references. Gross tumor volumes (GTVs) were contoured using lung windows; the margins were expanded by 5 mm to establish the planning treatment volume (PTV). Treatment plans were designed using a mean of 156 pencil beams. Doses delivered to the PTV ranged from 42 to 60 Gy in three fractions. The 30 Gy isodose contour extended at least 1 cm from the GTV to eradicate microscopic disease. Treatments were delivered using the CyberKnife system with tumor tracking. Examination and PET/CT imaging occurred at 3 month follow-up intervals. Forty patients (median age 76) with a median maximum tumor diameter of 2.6 cm (range, 1.4–5.0 cm) and a mean post-bronchodilator percent predicted forced expiratory volume in 1 s (FEV1) of 57% (range, 21–111%) were treated. A median dose of 48 Gy was delivered to the PTV over 3–13 days (median, 7 days). The 30 Gy isodose contour extended a mean 1.9 cm from the GTV. At a median 44 months (range, 12–72 months) follow-up, the 3 year Kaplan–Meier locoregional control and overall survival estimates compare favorably with contemporary wedge resection outcomes at 91 and 75%, respectively. CyberKnife is an effective treatment approach for stage I NSCLC that is similar to wedge resection, eradicating tumors with 1–2 cm margins in order to preserve lung function. Prospective randomized trials comparing CyberKnife with wedge resection are necessary to confirm equivalence.

  6. CyberKnife with tumor tracking: An effective alternative to wedge resection for high-risk surgical patients with stage I non-small cell lung cancer (NSCLC

    Directory of Open Access Journals (Sweden)

    Sean eCollins

    2012-02-01

    Full Text Available Published data suggests that wedge resection for stage I NSCLC results in improved overall survival compared to stereotactic body radiation therapy (SBRT. We report CyberKnife outcomes for high-risk surgical patients with biopsy-proven stage I NSCLC. PET/CT imaging was completed for staging. Three-to-five gold fiducial markers were implanted in or near tumors to serve as targeting references. Gross tumor volumes (GTVs were contoured using lung windows; the margins were expanded by 5 mm to establish the planning treatment volume (PTV. Treatment plans were designed using hundreds of pencil beams. Doses delivered to the PTV ranged from 42-60 Gy in 3 fractions. The 30-Gy isodose contour extended at least 1cm from the GTV to eradicate microscopic disease. Treatments were delivered using the CyberKnife system with tumor tracking. Examination and PET/CT imaging occurred at 3-month follow-up intervals. Forty patients (median age 76 with a median maximum tumor diameter of 2.6 cm (range, 1.4-5.0 cm and a mean post-bronchodilator percent predicted forced expiratory volume in 1 second (FEV1 of 57% (range, 21 - 111% were treated. A mean dose of 50 Gy was delivered to the PTV over 3 to 13 days (median, 7 days. The 30-Gy isodose contour extended a mean 1.9 cm from the GTV. At a median 44 months (range, 12 -72 months follow-up, the 3-year Kaplan-Meier locoregional control and overall survival estimates compare favorably with contemporary wedge resection outcomes at 91% and 75% , respectively. CyberKnife is an effective treatment approach for stage I NSCLC that is similar to wedge resection, eradicating tumors with 1 to 2 cm margins in order to preserve lung function. Prospective randomized trials comparing CyberKnife with wedge resection are necessary to confirm equivalence.

  7. Effects of fractionated stereotactic radiotherapy for primary hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Choi, Byeong Ock; Jang, Hong Seok; Kang, Young Nam; Choi, Ihl Bhong; Kang, Ki Mun; Chai, Gyu Young; Lee, Sang Wook

    2005-01-01

    Reports on the outcome of curative radiotherapy for the primary hepatocellular carcinoma (HCC) are rarely encountered in the literature. In this study, we report our experience of a clinical trial where fractionated stereotactic radiotherapy (SRT) was used in treating a primary HCC. A retrospective analysis was performed on 20 patients who had been histologically diagnosed as HCC and treated by fractionated SRT. The long diameter of tumor measured by CT was 2 ∼ 6.5 cm (average: 3.8 cm). A single dose of radiation used in fractionated SRT was 5 or 10 Gy; each dose was prescribed based on the planning target volume and normalized to 85 ∼ 99% isocenter dose. Patients were treated 3 ∼ 5 times per week for 2 weeks, with each receiving a total dose of 50 Gy (the median dose: 50 Gy). The follow up period was 3 ∼ 55 months (the median follow up period: 23 months). The response rate was 60% (12 patients), with 4 patients showing complete response (20%), 8 patients showing partial response (40%), and 8 patients showing stable disease (40%). The 1-year and 2-year survival rates were 70.0% and 43.1%, respectively,and the median survival time was 20 months. The 1-year and 2-year disease free survival rates were 65% and 32.5%, respectively, and the median disease-free survival rate was 19 months. Some acute complications of the treatment were noted as follows: dyspepsia in 12 patients (60%), nausea/emesis in 8 patients (40%), and transient liver function impairment in 6 patients (30%). However, there was no treatment related death. The study indicates that fractionated SRT is a relatively safe and effective method for treating primary HCC. Thus, fractionated SRT may be suggested as a local treatment for HCC of small lesion and containing a single lesion, when the patients are inoperable or operation is refused by the patients. We thought that fractionated SRT is a challenging treatment modality for the HCC

  8. Fractionated stereotactic radiotherapy in the treatment of pituitary adenomas

    International Nuclear Information System (INIS)

    Kopp, C.; Theodorou, M.; Poullos, N.; Astner, S.T.; Geinitz, H.; Molls, M.; Stalla, G.K.; Meyer, B.; Nieder, C.; Tromsoe Univ.; Grosu, A.L

    2013-01-01

    Purpose: The purpose of this work was to evaluate tumor control and side effects associated with fractionated stereotactic radiotherapy (FSRT) in the management of residual or recurrent pituitary adenomas. Patients and methods: We report on 37 consecutive patients with pituitary adenomas treated with FSRT at our department. All patients had previously undergone surgery. Twenty-nine patients had nonfunctioning, 8 had hormone-producing adenoma. The mean total dose delivered by a linear accelerator was 49.4 Gy (range 45-52.2 Gy), 5 x 1.8 Gy weekly. The mean PTV was 22.8 ccm (range 2.0-78.3 ccm). Evaluation included serial imaging tests, endocrinologic and ophthalmologic examination. Results: Tumor control was 91.9 % for a median follow-up time of 57 months (range 2-111 months). Before FSRT partial hypopituitarism was present in 41 % of patients, while 35 % had anterior panhypopituitarism. After FSRT pituitary function remained normal in 22 %, 43 % had partial pituitary dysfunction, and 35 % had anterior panhypopituitarism. Visual acuity was stable in 76 % of patients, improved in 19 %, and deteriorated in 5 %. Visual fields remained stable in 35 patients (95 %), improved in one and worsened in 1 patient (2.7 %). Conclusion: FSRT is an effective and safe treatment for recurrent or residual pituitary adenoma. Good local tumor control and preservation of adjacent structures can be reached, even for large tumors. (orig.)

  9. Fractionated stereotactic radiotherapy in the treatment of pituitary adenomas

    Energy Technology Data Exchange (ETDEWEB)

    Kopp, C.; Theodorou, M.; Poullos, N.; Astner, S.T.; Geinitz, H.; Molls, M. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie; Stalla, G.K. [Max-Planck-Institut fuer Psychiatrie, Muenchen (Germany). Klinische Neuroendokrinologie; Meyer, B. [Technische Univ. Muenchen, Klinikum rechts der Isar (Germany). Neurochirurgische Klinik und Poliklinik; Nieder, C. [Nordland Hospital, Bodoe (Norway). Dept. of Oncology and Palliative Medicine; Tromsoe Univ. (Norway). Inst. of Clinical Medicine; Grosu, A.L [Freiburg Univ. (Germany). Klinik fuer Strahlenheilkunde

    2013-11-15

    Purpose: The purpose of this work was to evaluate tumor control and side effects associated with fractionated stereotactic radiotherapy (FSRT) in the management of residual or recurrent pituitary adenomas. Patients and methods: We report on 37 consecutive patients with pituitary adenomas treated with FSRT at our department. All patients had previously undergone surgery. Twenty-nine patients had nonfunctioning, 8 had hormone-producing adenoma. The mean total dose delivered by a linear accelerator was 49.4 Gy (range 45-52.2 Gy), 5 x 1.8 Gy weekly. The mean PTV was 22.8 ccm (range 2.0-78.3 ccm). Evaluation included serial imaging tests, endocrinologic and ophthalmologic examination. Results: Tumor control was 91.9 % for a median follow-up time of 57 months (range 2-111 months). Before FSRT partial hypopituitarism was present in 41 % of patients, while 35 % had anterior panhypopituitarism. After FSRT pituitary function remained normal in 22 %, 43 % had partial pituitary dysfunction, and 35 % had anterior panhypopituitarism. Visual acuity was stable in 76 % of patients, improved in 19 %, and deteriorated in 5 %. Visual fields remained stable in 35 patients (95 %), improved in one and worsened in 1 patient (2.7 %). Conclusion: FSRT is an effective and safe treatment for recurrent or residual pituitary adenoma. Good local tumor control and preservation of adjacent structures can be reached, even for large tumors. (orig.)

  10. Clinical Experiences With Onboard Imager KV Images for Linear Accelerator-Based Stereotactic Radiosurgery and Radiotherapy Setup

    International Nuclear Information System (INIS)

    Hong, Linda X.; Chen, Chin C.; Garg, Madhur; Yaparpalvi, Ravindra; Mah, Dennis

    2009-01-01

    Purpose: To report our clinical experiences with on-board imager (OBI) kV image verification for cranial stereotactic radiosurgery (SRS) and radiotherapy (SRT) treatments. Methods and Materials: Between January 2007 and May 2008, 42 patients (57 lesions) were treated with SRS with head frame immobilization and 13 patients (14 lesions) were treated with SRT with face mask immobilization at our institution. No margin was added to the gross tumor for SRS patients, and a 3-mm three-dimensional margin was added to the gross tumor to create the planning target volume for SRT patients. After localizing the patient with stereotactic target positioner (TaPo), orthogonal kV images using OBI were taken and fused to planning digital reconstructed radiographs. Suggested couch shifts in vertical, longitudinal, and lateral directions were recorded. kV images were also taken immediately after treatment for 21 SRS patients and on a weekly basis for 6 SRT patients to assess any intrafraction changes. Results: For SRS patients, 57 pretreatment kV images were evaluated and the suggested shifts were all within 1 mm in any direction (i.e., within the accuracy of image fusion). For SRT patients, the suggested shifts were out of the 3-mm tolerance for 31 of 309 setups. Intrafraction motions were detected in 3 SRT patients. Conclusions: kV imaging provided a useful tool for SRS or SRT setups. For SRS setup with head frame, it provides radiographic confirmation of localization using the stereotactic target positioner. For SRT with mask, a 3-mm margin is adequate and feasible for routine setup when TaPo is combined with kV imaging

  11. Fractionated stereotactic radiotherapy of glomus jugulare tumors. Local control, toxicity, symptomatology, and quality of life

    International Nuclear Information System (INIS)

    Henzel, M.; Gross, M.W.; Failing, T.; Strassmann, G.; Engenhart-Cabillic, R.; Hamm, K.; Surber, G.; Kleinert, G.; Sitter, H.

    2007-01-01

    Background and Purpose: For glomus jugulare tumors, the goal of treatment is microsurgical excision. To minimize postoperative neurologic deficits, stereotactic radiosurgery (SRS) was performed as an alternative treatment option. Stereotactic fractionated radiotherapy (SRT) could be a further alternative. This study aims at the assessment of local control, side effects, and quality of life (QoL). Patients and Methods: Between 1999-2005, 17 patients were treated with SRT. 11/17 underwent previous operations. 6/17 received primary SRT. Treatment was delivered by a linear accelerator with 6-MV photons. Median cumulative dose was 57.0 Gy. Local control, radiologic regression, toxicity, and symptomatology were evaluated half-yearly by clinical examination and MRI scans. QoL was assessed by Short Form-36 (SF-36). Results: Median follow-up was 40 months. Freedom from progression and overall survival for 5 years were 100% and 93.8%. Radiologic regression was seen in 5/16 cases, 11/16 patients were stable. Median tumor shrinkage was 17.9% (p = 0.14). Severe acute toxicity (grade 3-4) or any late toxicity was never seen. Main symptoms improved in 9/16 patients, 7/16 were stable. QoL was not affected in patients receiving primary SRT. Conclusion: SRT offers an additional treatment option of high efficacy with less side effects, especially in cases of large tumors, morbidity, or recurrences after incomplete resections. (orig.)

  12. An ill-conditioning conformal radiotherapy analysis based on singular values decomposition

    International Nuclear Information System (INIS)

    Lefkopoulos, D.; Grandjean, P.; Bendada, S.; Dominique, C.; Platoni, K.; Schlienger, M.

    1995-01-01

    Clinical experience in stereotactic radiotherapy of irregular complex lesions had shown that optimization algorithms were necessary to improve the dose distribution. We have developed a general optimization procedure which can be applied to different conformal irradiation techniques. In this presentation this procedure is tested on the stereotactic radiotherapy modality of complex cerebral lesions treated with multi-isocentric technique based on the 'associated targets methodology'. In this inverse procedure we use the singular value decomposition (SVD) analysis which proposes several optimal solutions for the narrow beams weights of each isocentre. The SVD analysis quantifies the ill-conditioning of the dosimetric calculation of the stereotactic irradiation, using the condition number which is the ratio of the bigger to smaller singular values. Our dose distribution optimization approach consists on the study of the irradiation parameters influence on the stereotactic radiotherapy inverse problem. The adjustment of the different irradiation parameters into the 'SVD optimizer' procedure is realized taking into account the ratio of the quality reconstruction to the time calculation. It will permit a more efficient use of the 'SVD optimizer' in clinical applications for real 3D lesions. The evaluation criteria for the choice of satisfactory solutions are based on the dose-volume histograms and clinical considerations. We will present the efficiency of ''SVD optimizer'' to analyze and predict the ill-conditioning in stereotactic radiotherapy and to recognize the topography of the different beams in order to create optimal reconstructed weighting vector. The planification of stereotactic treatments using the ''SVD optimizer'' is examined for mono-isocentrically and complex dual-isocentrically treated lesions. The application of the SVD optimization technique provides conformal dose distribution for complex intracranial lesions. It is a general optimization procedure

  13. Toxicity after reirradiation of pulmonary tumours with stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Peulen, Heike; Karlsson, Kristin; Lindberg, Karin; Tullgren, Owe; Baumann, Pia; Lax, Ingmar; Lewensohn, Rolf; Wersäll, Peter

    2011-01-01

    Purpose: To assess toxicity and feasibility of reirradiation with stereotactic body radiotherapy (SBRT) after prior lung SBRT for primary lung cancer or lung metastases. Patients and materials: Twenty-nine patients reirradiated with SBRT on 32 lung lesions (11 central, 21 peripheral) were retrospectively reviewed. Median follow-up time was 12 months (range 1–97). The primary endpoint was toxicity, secondary endpoints were local control and overall survival time. Toxicity was scored according to the NCI-CTCAE version 3. Results: Grade 3–4 toxicity was scored 14 times in eight patients. Three patients died because of massive bleeding (grade 5). Larger clinical target volumes (CTV) and central tumour localization were associated with more severe toxicity. There was no correlation between mean lung dose (MLD) and lung toxicity. Local control at 5 months after reirradiation was 52%, as assessed by CT-scan (n = 12) or X-thorax (n = 3). A larger CTV was associated with poorer local control. Kaplan–Meier estimated 1- and 2-year survival rates were 59% and 43%, respectively. Conclusions: Reirradiation with SBRT is feasible although increased risk of toxicity was reported in centrally located tumours. Further research is warranted for more accurate selection of patients suitable for reirradiation with SBRT.

  14. Stereotactic Radiotherapy for Locally Recurrent Nasopharyngeal Carcinoma

    International Nuclear Information System (INIS)

    Leung, T.-W.; Wong, Victy Y.W.; Tung, Stewart Y.

    2009-01-01

    Purpose: To study the treatment outcome in patients with locally recurrent nasopharyngeal carcinoma (NPC) who were treated with stereotactic radiotherapy (SRT). Methods and Materials: Thirty patients with non-metastatic, locally recurrent NPC who were treated with curative intent between 1998 and 2002 were retrospectively analyzed. The International Union Against Cancer T-stage distribution at recurrence (rT) was as follows: rT1-14, rT2-7, rT3-3, and rT4-6. All patients were treated with SRT with a daily fractional dose of 2.5-4.5 Gy (median, 3 Gy) in 8-22 fractions (median, 18 fractions). Total equivalent dose (TED) was calculated by the linear-quadratic formula without a time factor correction. Results: The 5-year actuarial overall survival rate, disease-specific survival rate, and local failure-free survival (LFFS) rate for the whole group were 40%, 41.4%, and 56.8%, respectively. The 3-year LFFS rates of rT1-2 and rT3-4 diseases were 65% and 66.7%, respectively. Seven of nine patients who received a TED <55 Gy recurred locally compared with 4 of 21 patients who received ≥55 Gy. Their corresponding 5-year LFFS rates were 22.2% and 75.8% (p = 0.005). The TED was the only factor significant in affecting the local control on univariate analyses. Conclusion: SRT is an effective treatment for locally recurrent NPC. TED ≥55 Gy should be given to secure a higher local control rate. The late complication rates were acceptable for patients with rT1-2 disease. For patients with rT3-4 disease, more works need to be done to further decrease the late complications.

  15. Hypofractionated stereotactic body radiotherapy (SBRT) for liver metastases. A retrospective analysis of 74 patients treated in the Klinikum rechts der Isar Munich

    International Nuclear Information System (INIS)

    Heppt, Franz Johannes

    2013-01-01

    Purpose of this study was to evaluate the outcome of stereotactic body radiotherapy (SBRT) of liver metastases and prognostic factors for local control and overall survival. From 2000 to 2009 74 patients with 91 metastases were treated at the Department for Radiation Therapy and Oncology (TU Muenchen). With an observed local control rate of 75% after 1 year, SBRT proved as an effective local treatment option. Unfortunately, systemic tumor progression still dominates long term survival in many patients.

  16. Volumetric modulated arc therapy for delivery of hypofractionated stereotactic lung radiotherapy: A dosimetric and treatment efficiency analysis

    International Nuclear Information System (INIS)

    McGrath, Samuel D.; Matuszak, Martha M.; Yan Di; Kestin, Larry L.; Martinez, Alvaro A.; Grills, Inga S.

    2010-01-01

    Purpose/objective(s): Volumetric modulated arc therapy (VMAT) allows for intensity-modulated radiation delivery during gantry rotation with dynamic MLC motion, variable dose rates and gantry speed modulation. We compared VMAT plans with 3D-CRT for hypofractionated lung radiotherapy. Materials/methods: Twenty-one 3D-CRT plans for Stage IA lung cancer previously treated stereotactically were selected. VMAT plans were generated by optimizing machine aperture shape and radiation intensity at 10 deg. intervals. A partial arc range of 180 deg. was manually selected to coincide with tumor location. The arc was resampled down to 5 deg. intervals to ensure dose calculation accuracy. Identical planning objectives were used for VMAT/3D-CRT. Parameters assessed included dose to PTV and organs-at-risk (OAR), monitor units, and multiple conformity and homogeneity indices. Plans were delivered to a phantom for time comparison. Results: Lung V 20/12.5/10/5 were less with VMAT (relative reduction 4.5%, p = .02; 3.2%, p = .01; 2.6%, p = .01; 4.2%, p = .03, respectively). Mean/maximum-doses to PTV, dose to additional OARs, 95% isodose line conformity, and target volume homogeneity were equivalent. VMAT improved conformity at both the 80% (1.87 vs. 1.93, p = .08) and 50% isodose lines (5.19 vs. 5.65, p = .01). Treatment times were reduced significantly with VMAT (mean 6.1 vs. 11.9 min, p < .01). Conclusions: Single arc VMAT planning achieves highly conformal dose distributions while controlling dose to critical structures, including significant reduction in lung dose volume parameters. Employing a VMAT technique decreases treatment times by 37-63%, reducing the chance of error introduced by intrafraction variation. The quality and efficiency of VMAT is ideally suited for stereotactic lung radiotherapy delivery.

  17. Stereotactic ablative body radiotherapy for non-small-cell lung cancer: setup reproducibility with novel arms-down immobilization.

    Science.gov (United States)

    Moore, Karen; Paterson, Claire; Hicks, Jonathan; Harrow, Stephen; McJury, Mark

    2016-12-01

    A clinical evaluation of the intrafraction and interfraction setup accuracy of a novel thermoplastic mould immobilization device and patient position in early-stage lung cancer being treated with stereotactic radiotherapy at the Beatson West of Scotland Cancer Centre, Glasgow, UK. 35 patients were immobilized in a novel, arms-down position, with a four-point Klarity ™ (Klarity Medical Products, Ohio, US) clear thermoplastic mould fixed to a SinMed (CIVCO Medical solutions, lowa, US) head and neck board. A knee support was also used for patient comfort and support. Pre- and post-treatment kilovoltage cone beam CT (CBCT) images were fused with the planning CT scan to determine intra- and interfraction motion. A total of 175 CBCT scans were analysed in the longitudinal, vertical and lateral directions. The mean intrafraction errors were 0.05 ± 0.77 mm (lateral), 0.44 ± 1.2 mm (superior-inferior) and -1.44 ± 1.35 mm (anteroposterior), respectively. Mean composite three-dimensional displacement vector was 2.14 ± 1.2 mm. Interfraction errors were -0.66 ± 2.35 mm (lateral), -0.13 ± 3.11 mm (superior-inferior) and 0.00 ± 2.94 mm (anteroposterior), with three-dimensional vector 4.08 ± 2.73 mm. Setup accuracy for lung image-guided stereotactic ablative radiotherapy using a unique immobilization device, where patients have arms by their sides, has been shown to be safe and favourably comparable to other published setup data where more complex and cumbersome devices were utilised. There was no arm toxicity reported and low arm doses. Advances in knowledge: We report on the accuracy of a novel patient immobilization device.

  18. Inter- and Intrafraction Variability in Liver Position in Non-Breath-Hold Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Case, Robert B.; Sonke, Jan-Jakob; Moseley, Douglas J.; Kim, John; Brock, Kristy K.; Dawson, Laura A.

    2009-01-01

    Purpose: The inter- and intrafraction variability of liver position was assessed in patients with liver cancer treated with kilovoltage cone-beam computed tomography (CBCT)-guided stereotactic body radiotherapy. Methods and Materials: A total of 314 CBCT scans obtained in the treatment position immediately before and after each fraction were evaluated from 29 patients undergoing six-fraction, non-breath-hold stereotactic body radiotherapy for unresectable liver cancer. Off-line, the CBCT scans were sorted into 10 bins, according to the phase of respiration. The liver position (relative to the vertebral bodies) was measured using rigid alignment of the exhale CBCT liver with the exhale planning CT liver, following the alignment of the vertebrae. The interfraction liver position change was measured by comparing the pretreatment CBCT scans, and the intrafraction change was measured from the CBCT scans obtained immediately before and after each fraction. Results: The mean amplitude of liver motion for all patients was 1.8 mm (range, 0.1-5.7), 8.0 mm (range, 0.1-18.8), and 4.3 mm (range 0.1-12.1) in the medial-lateral (ML), craniocaudal (CC), and anteroposterior (AP) directions, respectively. The mean absolute ML, CC, and AP interfraction changes in liver position were 2.0 mm (90th percentile, 4.2), 3.5 mm (90th percentile, 7.3), and 2.3 mm (90th percentile, 4.7). The mean absolute intrafraction ML, CC, and AP changes were 1.3 mm (90th percentile, 2.9), 1.6 mm (90th percentile, 3.6), and 1.5 mm (90th percentile, 3.1), respectively. The interfraction changes were significantly larger than the intrafraction changes, with a CC systematic error of 2.9 and 1.1 mm, respectively. The intraobserver reproducibility (σ, n = 29 fractions) was 1.3 mm in the ML, 1.4 mm in the CC, and 1.6 mm in the AP direction. Conclusion: Interfraction liver position changes relative to the vertebral bodies are an important source of geometric uncertainty, providing a rationale for prefraction

  19. A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

    International Nuclear Information System (INIS)

    Sapkaroski, Daniel; Osborne, Catherine; Knight, Kellie A

    2015-01-01

    Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) may potentially mitigate these disadvantages. This review aims to assess the feasibility of emerging VMAT and IMRT-based SBRT treatment techniques and qualify which offers the best outcome for patients, whilst identifying any emerging and advantageous SBRT planning trends. A review and synthesis of data from current literature up to September 2013 was conducted on EMBASE, Medline, PubMed, Science Direct, Proquest central, Google Scholar and the Cochrane Database of Systematic reviews. Only full text papers comparing VMAT and or IMRT and or Static SBRT were included. Ten papers were identified that evaluated the results of VMAT/IMRT SBRT. Five related to medically inoperable stage 1 and 2 non-small-cell lung cancer (NSCLC), three to spinal metastasis, one related to abdominal lymph node malignancies, with the final one looking at pancreatic adenocarcinoma. Overall treatment times with VMAT were reduced by 66–70% for lung, 46–58% for spine, 42% and 21% for lymph node and pancreatic metastasis respectively, planning constraints were met with several studies showing improved organs at risk sparing with IMRT/VMAT to static SBRT. Both IMRT and VMAT were able to meet all planning constraints in the studies reviewed, with VMAT offering the greatest treatment efficiency. Early clinical outcomes with VMAT and IMRT SBRT have demonstrated excellent local control and favourable survival outcomes

  20. A review of stereotactic body radiotherapy – is volumetric modulated arc therapy the answer?

    Energy Technology Data Exchange (ETDEWEB)

    Sapkaroski, Daniel, E-mail: daniel.sapkaroski@gmail.com; Osborne, Catherine; Knight, Kellie A [Department of Medical Imaging and Radiation Sciences, Faculty of Medicine, Nursing and Health Sciences, School of Biomedical Sciences, Monash University, Clayton, Vic. (Australia)

    2015-06-15

    Stereotactic body radiotherapy (SBRT) is a high precision radiotherapy technique used for the treatment of small to moderate extra-cranial tumours. Early studies utilising SBRT have shown favourable outcomes. However, major disadvantages of static field SBRT include long treatment times and toxicity complications. Volumetric modulated arc therapy (VMAT) and intensity modulated radiotherapy (IMRT) may potentially mitigate these disadvantages. This review aims to assess the feasibility of emerging VMAT and IMRT-based SBRT treatment techniques and qualify which offers the best outcome for patients, whilst identifying any emerging and advantageous SBRT planning trends. A review and synthesis of data from current literature up to September 2013 was conducted on EMBASE, Medline, PubMed, Science Direct, Proquest central, Google Scholar and the Cochrane Database of Systematic reviews. Only full text papers comparing VMAT and or IMRT and or Static SBRT were included. Ten papers were identified that evaluated the results of VMAT/IMRT SBRT. Five related to medically inoperable stage 1 and 2 non-small-cell lung cancer (NSCLC), three to spinal metastasis, one related to abdominal lymph node malignancies, with the final one looking at pancreatic adenocarcinoma. Overall treatment times with VMAT were reduced by 66–70% for lung, 46–58% for spine, 42% and 21% for lymph node and pancreatic metastasis respectively, planning constraints were met with several studies showing improved organs at risk sparing with IMRT/VMAT to static SBRT. Both IMRT and VMAT were able to meet all planning constraints in the studies reviewed, with VMAT offering the greatest treatment efficiency. Early clinical outcomes with VMAT and IMRT SBRT have demonstrated excellent local control and favourable survival outcomes.

  1. Comparative analysis of thermoplastic masks versus vacuum cushions in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Navarro-Martin, Arturo; Cacicedo, Jon; Leaman, Olwen; Sancho, Ismael; García, Elvira; Navarro, Valentin; Guedea, Ferran

    2015-01-01

    To compare thermoplastic masks (TMP) and vacuum cushion system (VCS) to assess differences in interfraction set up accuracy in patients treated with stereotactic radiotherapy (SBRT) for oligometastatic lung cancer. Secondarily, to survey radiotherapy technologists to assess their satisfaction with the two systems. Retrospective study of patients treated with lung SBRT between 2008 to 2012 at our institution. Immobilization was performed for 73 treatment sessions (VCS = 40; TMP = 33). A total of 246 cone-beams were analysed. Patients considered ineligible for surgery with a life expectancy ≥6 months and performance status > 1 were included. Target lesion location was verified by cone beam computed tomography (CBCT) prior to each session, with displacements assessed by CBCT simulation prior to each treatment session. Couch shifts were registered prospectively in vertical, longitudinal, and latero-lateral directions to obtain Kernel coordinates (3D representation). Technologists were surveyed to assess their satisfaction with indexing, positioning, and learning curve of the two systems. Setup displacements were obtained in all patients for each treatment plan and for each session. To assess differences between the immobilization systems, a t-test (Welch) was performed. Mean displacements for the TMP and VC systems, respectively, were as follows: session one, 0.64 cm vs 1.05 cm (p = 0.0002); session two, 0.49 cm vs 1.02 cm (p < 0.0001), and session three, 0.56 vs 0.97 cm (p = 0.0011). TMP resulted in significantly smaller shifts vs. VCS in all three treatment sessions. Technologists rated the learning curve, set up, and positioning more highly for TMP versus VCS. Due to the high doses and steep gradients in lung SBRT, accurate and reproducible inter-fraction set up is essential. We found that thermoplastic masks offers better reproducibility with significantly less interfractional set up displacement than vacuum cushions. Moreover, radiotherapy technologists rated

  2. A Phase 1 Trial of an Immune Checkpoint Inhibitor plus Stereotactic Ablative Radiotherapy in Patients with Inoperable Stage I Non-Small Cell Lung Cancer

    Science.gov (United States)

    2017-10-01

    with Inoperable Stage I Non-Small Cell Lung Cancer PRINCIPAL INVESTIGATOR: Karen Kelly, MD CONTRACTING ORGANIZATION: University of California...Inhibitor plus Stereotactic Ablative Radiotherapy in Patients with Inoperable Stage I Non-Small Cell Lung Cancer 5b. GRANT NUMBER W81XWH-15-2-0063...immune checkpoint inhibitor MPDL3280A (atezolizumab) in early stage inoperable non-small cell lung cancer . The trial is comprised of a traditional 3 + 3

  3. Beam shaping for conformal fractionated stereotactic radiotherapy: a modeling study

    International Nuclear Information System (INIS)

    Hacker, Fred L.; Kooy, Hanne M.; Bellerive, Marc R.; Killoran, Joseph H.; Leber, Zachary H.; Shrieve, Dennis C.; Tarbell, Nancy J.; Loeffler, Jay S.

    1997-01-01

    Purpose: The patient population treated with fractionated stereotactic radiotherapy (SRT) is significantly different than that treated with stereotactic radiosurgery (SRS). Generally, lesions treated with SRT are larger, less spherical, and located within critical regions of the central nervous system; hence, they offer new challenges to the treatment planner. Here a simple, cost effective, beam shaping system has been evaluated relative to both circular collimators and an ideal dynamically conforming system for effectiveness in providing conformal therapy for these lesions. Methods and Materials: We have modeled a simple system for conformal arc therapy using four independent jaws. The jaw positions and collimator angle are changed between arcs but held fixed for the duration of each arc. Eleven previously treated SRT cases have been replanned using this system. The rectangular jaw plans were then compared to the original treatment plans which used circular collimators. The plans were evaluated with respect to tissue sparing at 100%, 80%, 50%, and 20% of the prescription dose. A plan was also done for each tumor in which the beam aperture was continuously conformed to the beams eye view projection of the tumor. This was used as an ideal standard for conformal therapy in the absence of fluence modulation. Results: For tumors with a maximum extent of over 3.5 cm the rectangular jaw plans reduced the mean volume of healthy tissue involved at the prescription dose by 57% relative to the circular collimator plans. The ideal conformal plans offered no significant further improvement at the prescription dose. The relative advantage of the rectangular jaw plans decreased at lower isodoses so that at 20% of the prescription dose tissue involvement for the rectangular jaw plans was equivalent to that for the circular collimator plans. At these isodoses the ideal conformal plans gave substantially better tissue sparing. Conclusion: A simple and economical field shaping

  4. SU-F-SPS-11: The Dosimetric Comparison of Truebeam 2.0 and Cyberknife M6 Treatment Plans for Brain SRS Treatment

    Energy Technology Data Exchange (ETDEWEB)

    Mabhouti, H; Sanli, E; Cebe, M; Codel, G; Pacaci, P; Serin, E; Kucuk, N; Kucukmorkoc, E; Doyuran, M; Canoglu, D; Altinok, A; Acar, H; Caglar Ozkok, H [Medipol University, Istanbul, Istanbul (Turkey)

    2016-06-15

    Purpose: Brain stereotactic radiosurgery involves the use of precisely directed, single session radiation to create a desired radiobiologic response within the brain target with acceptable minimal effects on surrounding structures or tissues. In this study, the dosimetric comparison of Truebeam 2.0 and Cyberknife M6 treatment plans were made. Methods: For Truebeam 2.0 machine, treatment planning were done using 2 full arc VMAT technique with 6 FFF beam on the CT scan of Randophantom simulating the treatment of sterotactic treatments for one brain metastasis. The dose distribution were calculated using Eclipse treatment planning system with Acuros XB algorithm. The treatment planning of the same target were also done for Cyberknife M6 machine with Multiplan treatment planning system using Monte Carlo algorithm. Using the same film batch, the net OD to dose calibration curve was obtained using both machine by delivering 0- 800 cGy. Films were scanned 48 hours after irradiation using an Epson 1000XL flatbed scanner. Dose distribution were measured using EBT3 film dosimeter. The measured and calculated doses were compared. Results: The dose distribution in the target and 2 cm beyond the target edge were calculated on TPSs and measured using EBT3 film. For cyberknife plans, the gamma analysis passing rates between measured and calculated dose distributions were 99.2% and 96.7% for target and peripheral region of target respectively. For Truebeam plans, the gamma analysis passing rates were 99.1% and 95.5% for target and peripheral region of target respectively. Conclusion: Although, target dose distribution calculated accurately by Acuros XB and Monte Carlo algorithms, Monte carlo calculation algorithm predicts dose distribution around the peripheral region of target more accurately than Acuros algorithm.

  5. Hypofractionated stereotactic radiotherapy combined with topotecan in recurrent malignant glioma

    International Nuclear Information System (INIS)

    Wurm, Reinhard E.; Kuczer, David A.; Schlenger, Lorenz; Matnjani, Gesa; Scheffler, Dirk; Cosgrove, Vivian P.; Ahlswede, Julia; Woiciechowsky, Christian; Budach, Volker

    2006-01-01

    Purpose: To assess hypofractionated stereotactic radiotherapy (H-SRT) with concurrent topotecan in patients with recurrent malignant glioma. Methods and Materials: Between February 1998 and December 2001, 25 patients with recurrent malignant glioma were treated in a phase I-II study (8 females and 17 males; median age, 45 years; range, 11-66 years; median Karnofsky performance status, 80%, range, 50-100%; median Mini Mental Standard Examination score, 25 points; range, 10-30 points). Of the 25 patients, 20% had World Health Organization Grade III and 80% World Health Organization Grade IV glioma. All patients had been treated previously by external beam radiotherapy with 54.4 Gy in 34 fractions twice daily, at least 6 h apart, within 3.5 weeks or 60 Gy in 30 fractions within 6 weeks. In addition, 84% had already received at least one chemotherapy regimen for recurrence. The median H-SRT dose at the 80% isodose was 25 Gy, and the maximal dose was 30 Gy delivered in five to six fractions on consecutive days. Topotecan (1.1 mg/m 2 /d) was given as a continuous i.v. infusion during H-SRT. Depending on the toxicity and compliance, patients received an additional 48 topotecan courses. Results: For all patients, the actuarial median progression-free survival was 10.5 months (range, 1.4-47.8 months), the median functional survival was 12.6 months (range, 1.6-49.5 months), and the median overall survival was 14.5 months (range, 3-56.4 months). Twelve percent of patients developed presumed adverse radiation effects (Radiation Therapy Oncology Group Grade 2). According to the Common Toxicity Criteria, version 2.0, no topotecan-related Grade 4 toxicity was noted. Grade 3 neutropenia was documented after 14 and Grade 3 thrombopenia after 12 courses. Conclusion: H-SRT with topotecan is feasible and well-tolerated in patients with recurrent high-grade glioma and results in similar survival compared with other repeat treatment modalities

  6. Present status and future aspects of highly precise radiotherapy

    International Nuclear Information System (INIS)

    Oita, Masataka; Takegawa, Yoshihiro; Maezawa, Hiroshi; Ikushima, Hitoshi; Osaki, Kyosuke; Nishitani, Hiromu

    2006-01-01

    This review describes about therapeutic equipments, irradiation technology, actual practice of highly precise radiotherapy (RT) and its tasks in future. Development of radiation equipments has made the therapy highly precise. At present, there are reportedly 836 linacs and 23 microtrons in Japan (March, 2005), most of which are computerized, new generation equipments. Image-guided RT, CT-linac system, real-time tumor-tracking RT (RTRT), tomotherapy and cyberknife are introduced owing to development of concerned devices and equipments. In addition, there are 7 facilities with proton and/or heavy ion beams. In parallel with the machine development above, irradiation has become to that from 2D to 3D by multi-gate technique with use of multi-leaf collimator and intensity-modulated RT is introduced. RTRT is an example of 4D RT. Practically, stereotactic irradiation (STI) to brain tumor has resulted in 1-year cumulative survival rate of 58% in 16 cases (23 foci, median size 1.2 cm and volume 0.57 ml) with median dose of 21.0 Gy in authors' hospital. STI in the early stage lung cancers is also practically conducted without severe adverse effects. Future tasks involve the further development of irradiation techniques and RT planning, QA/QC system, and raising of experts in related fields, which is a national problem. (T.I.)

  7. Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design.

    Science.gov (United States)

    Theelen, A; Martens, J; Bosmans, G; Houben, R; Jager, J J; Rutten, I; Lambin, P; Minken, A W; Baumert, B G

    2012-01-01

    The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB® mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB® frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted.

  8. Relocatable fixation systems in intracranial stereotactic radiotherapy. Accuracy of serial CT scans and patient acceptance in a randomized design

    International Nuclear Information System (INIS)

    Theelen, A.; Martens, J.; Bosmans, G.; Houben, R.; Jager, J.J.; Rutten, I.; Lambin, P.; Baumert, B.G.; Minken, A.W.; Radiotherapeutic Inst. RISO, Deventer

    2012-01-01

    The goal was to provide a quantitative evaluation of the accuracy of three different fixation systems for stereotactic radiotherapy and to evaluate patients' acceptance for all fixations. Methods A total of 16 consecutive patients with brain tumours undergoing fractionated stereotactic radiotherapy (SCRT) were enrolled after informed consent (Clinical trials.gov: NCT00181350). Fixation systems evaluated were the BrainLAB registered mask, with and without custom made bite-block (fixations S and A) and a homemade neck support with bite-block (fixation B) based on the BrainLAB registered frame. The sequence of measurements was evaluated in a randomized manner with a cross-over design and patients' acceptance by a questionnaire. Results The mean three-dimensional (3D) displacement and standard deviations were 1.16 ± 0.68 mm for fixation S, 1.92 ± 1.28 and 1.70 ± 0.83 mm for fixations A and B, respectively. There was a significant improvement of the overall alignment (3D vector) when using the standard fixation instead of fixation A or B in the craniocaudal direction (p = 0.037). Rotational deviations were significantly less for the standard fixation S in relation to fixations A (p = 0.005) and B (p = 0.03). EPI imaging with off-line correction further improved reproducibility. Five out of 8 patients preferred the neck support with the bite-block. Conclusion The mask fixation system in conjunction with a bite-block is the most accurate fixation for SCRT reducing craniocaudal and rotational movements. Patients favoured the more comfortable but less accurate neck support. To optimize the accuracy of SCRT, additional regular portal imaging is warranted. (orig.)

  9. Hypofractionated stereotactic radiation therapy in three to five fractions for vestibular schwannoma

    International Nuclear Information System (INIS)

    Morimoto, Masahiro; Yoshioka, Yasuo; Kotsuma, Tadayuki

    2013-01-01

    The objective of this study was to retrospectively examine the outcomes of hypofractionated stereotactic radiation therapy in three to five fractions for vestibular schwannomas. Twenty-five patients with 26 vestibular schwannomas were treated with hypofractionated stereotactic radiation therapy using a CyberKnife. The vestibular schwannomas of 5 patients were associated with type II neurofibromatosis. The median follow-up time was 80 months (range: 6-167); the median planning target volume was 2.6 cm 3 (0.3-15.4); and the median prescribed dose (≥D90) was 21 Gy in three fractions (18-25 Gy in three to five fractions). Progression was defined as ≥2 mm 3-dimensional post-treatment tumor enlargement excluding transient expansion. Progression or any death was counted as an event in progression-free survival rates, whereas only progression was counted in progression-free rates. The 7-year progression-free survival and progression-free rates were 78 and 95%, respectively. Late adverse events (≥3 months) with grades based on Common Terminology Criteria for Adverse Events, v4.03 were observed in 6 patients: Grade 3 hydrocephalus in one patient, Grade 2 facial nerve disorders in two and Grade 1-2 tinnitus in three. In total, 12 out of 25 patients maintained pure tone averages ≤50 dB before hypofractionated stereotactic radiation therapy, and 6 of these 12 patients (50%) maintained pure tone averages at this level at the final audiometric follow-up after hypofractionated stereotactic radiation therapy. However, gradient deterioration of pure tone average was observed in 11 of these 12 patients. The mean pure tone averages before hypofractionated stereotactic radiation therapy and at the final follow-up for the aforementioned 12 patients were 29.8 and 57.1 dB, respectively. Treating vestibular schwannomas with hypofractionated stereotactic radiation therapy in three to five fractions may prevent tumor progression with tolerable toxicity. However, gradient

  10. Hypofractionated stereotactic radiation therapy in three to five fractions for vestibular schwannoma

    Energy Technology Data Exchange (ETDEWEB)

    Morimoto, Masahiro; Yoshioka, Yasuo [Osaka Univ., Graduate School of Medicine, Suita, Osaka (Japan); Kotsuma, Tadayuki [Kinki-chuo Chest Medical Center, Sakai, Osaka (Japan); others, and

    2013-08-15

    The objective of this study was to retrospectively examine the outcomes of hypofractionated stereotactic radiation therapy in three to five fractions for vestibular schwannomas. Twenty-five patients with 26 vestibular schwannomas were treated with hypofractionated stereotactic radiation therapy using a CyberKnife. The vestibular schwannomas of 5 patients were associated with type II neurofibromatosis. The median follow-up time was 80 months (range: 6-167); the median planning target volume was 2.6 cm{sup 3} (0.3-15.4); and the median prescribed dose ({>=}D90) was 21 Gy in three fractions (18-25 Gy in three to five fractions). Progression was defined as {>=}2 mm 3-dimensional post-treatment tumor enlargement excluding transient expansion. Progression or any death was counted as an event in progression-free survival rates, whereas only progression was counted in progression-free rates. The 7-year progression-free survival and progression-free rates were 78 and 95%, respectively. Late adverse events ({>=}3 months) with grades based on Common Terminology Criteria for Adverse Events, v4.03 were observed in 6 patients: Grade 3 hydrocephalus in one patient, Grade 2 facial nerve disorders in two and Grade 1-2 tinnitus in three. In total, 12 out of 25 patients maintained pure tone averages {<=}50 dB before hypofractionated stereotactic radiation therapy, and 6 of these 12 patients (50%) maintained pure tone averages at this level at the final audiometric follow-up after hypofractionated stereotactic radiation therapy. However, gradient deterioration of pure tone average was observed in 11 of these 12 patients. The mean pure tone averages before hypofractionated stereotactic radiation therapy and at the final follow-up for the aforementioned 12 patients were 29.8 and 57.1 dB, respectively. Treating vestibular schwannomas with hypofractionated stereotactic radiation therapy in three to five fractions may prevent tumor progression with tolerable toxicity. However, gradient

  11. Stereotactic radiosurgery and fractionated stereotactic radiotherapy for the treatment of acoustic schwannomas: comparative observations of 125 patients treated at one institution

    International Nuclear Information System (INIS)

    Andrews, David W.; Suarez, Oscar; Goldman, H. Warren; Downes, M. Beverly; Bednarz, Greg; Corn, Benjamin W.; Werner-Wasik, Maria; Rosenstock, Jeffrey; Curran, Walter J.

    2001-01-01

    Background: Stereotactic radiosurgery (SRS) and, more recently, fractionated stereotactic radiotherapy (SRT) have been recognized as noninvasive alternatives to surgery for the treatment of acoustic schwannomas. We review our experience of acoustic tumor treatments at one institution using a gamma knife for SRS and the first commercial world installation of a dedicated linac for SRT. Methods: Patients were treated with SRS on the gamma knife or SRT on the linac from October 1994 through August 2000. Gamma knife technique involved a fixed-frame multiple shot/high conformality single treatment, whereas linac technique involved daily conventional fraction treatments involving a relocatable frame, fewer isocenters, and high conformality established by noncoplanar arc beam shaping and differential beam weighting. Results: Sixty-nine patients were treated on the gamma knife, and 56 patients were treated on the linac, with 1 NF-2 patient common to both units. Three patients were lost to follow-up, and in the remaining 122 patients, mean follow-up was 119±67 weeks for SRS patients and 115±96 weeks for SRT patients. Tumor control rates were high (≥97%) for sporadic tumors in both groups but lower for NF-2 tumors in the SRT group. Cranial nerve morbidities were comparably low in both groups, with the exception of functional hearing preservation, which was 2.5-fold higher in patients who received conventional fraction SRT. Conclusion: SRS and SRT represent comparable noninvasive treatments for acoustic schwannomas in both sporadic and NF-2 patient groups. At 1-year follow-up, a significantly higher rate of serviceable hearing preservation was achieved in SRT sporadic tumor patients and may therefore be preferable to alternatives including surgery, SRS, or possibly observation in patients with serviceable hearing

  12. Treatment of pituitary adenomas by fractionated stereotactic radiotherapy: A prospective study of 110 patients

    International Nuclear Information System (INIS)

    Colin, Philippe; Jovenin, Nicolas; Delemer, Brigitte; Caron, Jean; Grulet, Herve; Hecart, Annie-Claude; Lukas, Celine; Bazin, Arnaud; Bernard, Mary-Helene; Scherpereel, Bernard; Peruzzi, Philippe; Nakib, Iab; Redon, Charles; Rousseaux, Pascal

    2005-01-01

    Purpose: To optimize and reduce the toxicity of pituitary adenoma irradiation by assessing the feasibility and effectiveness of fractionated stereotactic radiotherapy (FSR). Methods and Materials: Between 1990 and 1999, 110 consecutive patients, 47 with a functioning adenoma, were treated according to a strategy of either early surgery and FSR (n = 89) or FSR only (n = 21). Of the 110 patients, 75 had persistent macroscopic tumor and 47 persistent hormonal secretions; 15 were treated in the prophylactic setting. The linear accelerator-delivered dose was 50.4 Gy (5 x 1.8 Gy weekly), with a 2-mm safety margin. Results: After a minimal follow-up of 48 months, only 1 patient had developed progression. Of the 110 patients, 27 (36%) had a complete tumor response, 67 (89.3%) had an objective tumor response, 20 (42%) had a hormonal complete response, and 47 (100%) had a hormonal objective tumor response. The proportion of patients without a complete tumor response, objective tumor response, complete hormonal response, and objective hormonal response was 85.1%, 62%, 83%, and 59.3% at 4 years and 49.3%, 9%, 59.3%, and 10.6% at 8 years, respectively. The sole unfavorable predictive factor was preoperative SSE >20 mm for tumor response (p = 0.01) and growth hormone adenoma for the hormonal response (p <0.001). No late complications, except for pituitary deficiency, were reported, with a probability of requiring hormonal replacement of 28.5% and 35% at 4 and 8 years, respectively. Nonfunctioning status was the sole unfavorable factor (p = 0.0016). Conclusions: Surgery plus FSR is safe and effective. FSR focused to the target volume seems more suitable than standard radiotherapy, and standard fractionation reduces the risk of optic neuropathy sometimes observed after single-dose radiosurgery. Therefore, FSR allows us to consider combined transrhinoseptal surgery and early radiotherapy, with a curative goal without patient selection

  13. Pelvic re-irradiation using stereotactic ablative radiotherapy (SABR): A systematic review.

    Science.gov (United States)

    Murray, Louise Janet; Lilley, John; Hawkins, Maria A; Henry, Ann M; Dickinson, Peter; Sebag-Montefiore, David

    2017-11-01

    To perform a systematic review regarding the use of stereotactic ablative radiotherapy (SABR) for the re-irradiation of recurrent malignant disease within the pelvis, to guide the clinical implementation of this technique. A systematic search strategy was adopted using the MEDLINE, EMBASE and Cochrane Library databases. 195 articles were identified, of which 17 were appropriate for inclusion. Studies were small and data largely retrospective. In total, 205 patients are reported to have received pelvic SABR re-irradiation. Dose and fractionation schedules and re-irradiated volumes are highly variable. Little information is provided regarding organ at risk constraints adopted in the re-irradiation setting. Treatment appears well-tolerated overall, with nine grade 3 and six grade 4 toxicities amongst thirteen re-irradiated patients. Local control at one year ranged from 51% to 100%. Symptomatic improvements were also noted. For previously irradiated patients with recurrent pelvic disease, SABR re-irradiation could be a feasible intervention for those who otherwise have limited options. Evidence to support this technique is limited but shows initial promise. Based on the available literature, suggestions for a more formal SABR re-irradiation pathway are proposed. Prospective studies and a multidisciplinary approach are required to optimise future treatment. Copyright © 2017 Elsevier B.V. All rights reserved.

  14. Outcome of four-dimensional stereotactic radiotherapy for centrally located lung tumors

    International Nuclear Information System (INIS)

    Nuyttens, Joost J.; Voort van Zyp, Noelle C. van der; Praag, John; Aluwini, Shafak; Klaveren, Rob J. van; Verhoef, Cornelis; Pattynama, Peter M.; Hoogeman, Mischa S.

    2012-01-01

    Purpose: To assess local control, overall survival, and toxicity of four-dimensional, risk-adapted stereotactic body radiotherapy (SBRT) delivered while tracking respiratory motion in patients with primary and metastatic lung cancer located in the central chest. Methods: Fifty-eight central lesions of 56 patients (39 with primary, 17 with metastatic tumors) were treated. Fifteen tumors located near the esophagus were treated with 6 fractions of 8 Gy. Other tumors were treated according to the following dose escalation scheme: 5 fractions of 9 Gy (n = 6), then 5 fractions of 10 Gy (n = 15), and finally 5 fractions of 12 Gy (n = 22). Results: Dose constraints for critical structures were generally achieved; in 21 patients the coverage of the PTV was reduced below 95% to protect adjacent organs at risk. At a median follow-up of 23 months, the actuarial 2-years local tumor control was 85% for tumors treated with a BED >100 Gy compared to 60% for tumors treated with a BED ⩽100 Gy. No grade 4 or 5 toxicity was observed. Acute grade 1–2 esophagitis was observed in 11% of patients. Conclusion: SBRT of central lung lesions can be safely delivered, with promising early tumor control in patients many of whom have severe comorbid conditions.

  15. Preliminary Results of Fractionated Stereotactic Radiotherapy After Cyst Drainage for Craniopharyngioma in Adults

    International Nuclear Information System (INIS)

    Kanesaka, Naoto; Mikami, Ryuji; Nakayama, Hidetsugu; Nogi, Sachika; Tajima, Yu; Nakajima, Nobuyuki; Wada, Jun; Miki, Tamotsu; Haraoka, Jou; Okubo, Mitsuru; Sugahara, Shinji; Tokuuye, Koichi

    2012-01-01

    Purpose: To retrospectively evaluate the effectiveness of fractionated stereotactic radiotherapy (FSRT) for craniopharyngioma. Methods and Materials: Between 1999 and 2005, 16 patients with craniopharyngioma were referred to Tokyo Medical University Hospital. They received FSRT alone after histologic confirmation by needle biopsy and underwent cyst drainage via endoscopy. The median prescription dose fraction was 30 Gy in six fractions. All patients except 1 were followed up until December 2009 or death. Results: The median follow-up period was 52 months (range, 4–117 months). Of the 17 patients, 3 experienced recurrence 4 to 71 months after FSRT. The 3-year local control rate was 82.4%. One patient died of thyroid cancer, and the 3-year survival rate was 94.1%. Eight patients had improved visual fields at a median of 2.5 months after FSRT, but hormonal functions did not improve in any patient. Conclusions: FSRT after cyst drainage seems to be safe and effective for patients with craniopharyngiomas, and it may be a safe alternative to surgery.

  16. Preliminary Results of Fractionated Stereotactic Radiotherapy After Cyst Drainage for Craniopharyngioma in Adults

    Energy Technology Data Exchange (ETDEWEB)

    Kanesaka, Naoto, E-mail: kaneka@tokyo-med.ac.jp [Department of Radiology, Tokyo Medical University Hospital, Tokyo (Japan); Mikami, Ryuji; Nakayama, Hidetsugu; Nogi, Sachika; Tajima, Yu [Department of Radiology, Tokyo Medical University Hospital, Tokyo (Japan); Nakajima, Nobuyuki; Wada, Jun; Miki, Tamotsu; Haraoka, Jou [Department of Neurosurgery, Tokyo Medical University Hospital, Tokyo (Japan); Okubo, Mitsuru [Department of Radiology, Tokyo Medical University Hachioji Medical Center, Tokyo (Japan); Sugahara, Shinji [Department of Radiology, Tokyo Medical University Ibaraki Medical Center, Tokyo (Japan); Tokuuye, Koichi [Department of Radiology, Tokyo Medical University Hospital, Tokyo (Japan)

    2012-03-15

    Purpose: To retrospectively evaluate the effectiveness of fractionated stereotactic radiotherapy (FSRT) for craniopharyngioma. Methods and Materials: Between 1999 and 2005, 16 patients with craniopharyngioma were referred to Tokyo Medical University Hospital. They received FSRT alone after histologic confirmation by needle biopsy and underwent cyst drainage via endoscopy. The median prescription dose fraction was 30 Gy in six fractions. All patients except 1 were followed up until December 2009 or death. Results: The median follow-up period was 52 months (range, 4-117 months). Of the 17 patients, 3 experienced recurrence 4 to 71 months after FSRT. The 3-year local control rate was 82.4%. One patient died of thyroid cancer, and the 3-year survival rate was 94.1%. Eight patients had improved visual fields at a median of 2.5 months after FSRT, but hormonal functions did not improve in any patient. Conclusions: FSRT after cyst drainage seems to be safe and effective for patients with craniopharyngiomas, and it may be a safe alternative to surgery.

  17. Stereotactic Body Radiotherapy for Oligometastasis: Opportunities for Biology to Guide Clinical Management.

    Science.gov (United States)

    Correa, Rohann J M; Salama, Joseph K; Milano, Michael T; Palma, David A

    2016-01-01

    Oligometastasis refers to a state of limited metastatic disease burden, in which surgical or ablative treatment to all known visible metastases holds promise to extend survival or even effect cure. Stereotactic body radiotherapy is a form of radiation treatment capable of delivering a high biologically effective dose of radiation in a highly conformal manner, with a favorable toxicity profile. Enthusiasm for oligometastasis ablation, however, should be counterbalanced against the limited supporting evidence. It remains unknown to what extent (if any) ablation influences survival or quality of life. Rising clinical equipoise necessitates the completion of randomized controlled trials to assess this, several of which are underway. However, a lack of clear identification criteria or biomarkers to define the oligometastatic state hampers optimal patient selection.This narrative review explores the evolutionary origins of oligometastasis, the steps of the metastatic process at which oligometastases may arise, and the biomolecular mediators of this state. It discusses clinical outcomes with treatment of oligometastases, ongoing trials, and areas of basic and translational research that may lead to novel biomarkers. These efforts should provide a clearer, biomolecular definition of oligometastatic disease and aid in the accurate selection of patients for ablative therapies.

  18. Preliminary shielding calculation for the system of CyberKnife robotic radiosurgery; Calculo de blindagem preliminar para o sistema de radiocirurgia robotica CyberKnife

    Energy Technology Data Exchange (ETDEWEB)

    Toreti, Dalila; Xavier, Clarice; Moura, Fabio, E-mail: clarice.xavier@rem.ind.b, E-mail: fabio.moura@rem.ind.b [REM Industria e Comercio Ltda., Sao Paulo, SP (Brazil)

    2011-10-26

    The CyberKnife robotic system uses a manipulator with six grade of freedom for positioning a 6 MV Linac accelerator for treatment of lesions. This paper presents calculations for a standard room, with 200 cm of thickness walls primary, build for a CyberKnife system, and calculations for a room originally designed for a Linac conventional (with gantry), with secondary barriers of 107 cm thickness. After the realization of shielding for both rooms, the results shown that walls of standard room with 200 cm thickness are adequate for the secondary shield, and for a room with a conventional Linac, from all six evaluated points, two would require additional shielding of nine cm and four cm of concrete with 2.4 g/cubic cm. This shows that the CyberKnife system can be installed in a originally designed room for a conventional Linac with neither restrict nor any shielding, since no incidence of beams on the secondary barriers is existent

  19. Neuropsychological outcome after fractionated stereotactic radiotherapy (FSRT) for base of skull meningiomas: a prospective 1-year follow-up

    International Nuclear Information System (INIS)

    Steinvorth, Sarah; Welzel, Grit; Fuss, Martin; Debus, Juergen; Wildermuth, Susanne; Wannenmacher, Michael; Wenz, Frederik

    2003-01-01

    Purpose: The purpose of this study was to evaluate the cognitive outcome after fractionated stereotactic radiotherapy (FSRT) in patients with base of skull meningiomas. Methods and material: A total of 40 patients with base of skull meningiomas were neuro psychologically evaluated before, after the first fraction (1.8 Gy), at the end of FSRT (n=37), 6 weeks (n=24), 6 (n=18) and 12 months (n=14) after FSRT. A comprehensive test battery including assessment of general intelligence, attention and memory functions was used. Alternate forms were used and current mood state was controlled. Results: After the first fraction a transient decline in memory function and simultaneous improvements in attention functions were observed. No cognitive deteriorations were seen during further follow-up, but increases in attention and memory functions were observed. Mood state improved after the first fraction, at the end of radiotherapy and 6 weeks after radiotherapy. Conclusion: The present data support the conclusion that the probability for the development of permanent cognitive dysfunctions appears to be very low after FSRT. The transient memory impairments on day 1 are interpreted as most likely related to an increase of a preexisting peritumoral edema, whereas the significant acute improvements in attention functions are interpreted as practice effects. An analysis of localization specific effects of radiation failed to show clear hemisphere specific cognitive changes

  20. Potential impact of {sup 68}Ga-DOTATOC PET/CT on stereotactic radiotherapy planning of meningiomas

    Energy Technology Data Exchange (ETDEWEB)

    Nyuyki, Fonyuy; Plotkin, Michail; Michel, Roger; Steffen, Ingo; Fahdt, Daniel; Brenner, Winfried [Charite-Universitaetsmedizin Berlin, Department for Nuclear Medicine, Berlin (Germany); Graf, Reinhold [Charite-Universitaetsmedizin Berlin, Department for Radiation Therapy, Campus Virchow, Berlin (Germany); Denecke, Timm [Charite-Universitaetsmedizin Berlin, Department for Radiology, Campus Virchow, Berlin (Germany); Geworski, Lilli [Charite-Universitaetsmedizin Berlin, Department for Nuclear Medicine, Berlin (Germany); Medizinische Hochschule Hannover, Department for Radiation Safety and Medical Physics, Hannover (Germany); Wurm, Reinhard [Charite-Universitaetsmedizin Berlin, Department for Radiation Therapy, Campus Virchow, Berlin (Germany); Klinikum Frankfurt (Oder), Department for Radiation Therapy and Radiooncology, Frankfurt (Germany)

    2010-02-15

    Since meningiomas show a high expression of somatostatin receptor subtype 2, PET with {sup 68}Ga-DOTATOC was proposed as an additional imaging modality beside CT and MRI for planning radiotherapy. We investigated the input of {sup 68}Ga-DOTATOC-PET/CT on the definition of the ''gross tumour volume'' (GTV) in meningiomas, in order to assess the potential value of this method. Prior to radiotherapy, 42 patients with meningiomas (26 f, 16 m, mean age 55) underwent MRI and {sup 68}Ga-DOTATOC-PET/CT examinations. History: operated n = 24, radiotherapy n = 1, operation and radiotherapy n = 8, no treatment n = 9. PET/CT and MRI data were co-registered using a BrainLAB workstation. For comparison, the GTV was defined first under consideration of CT and MRI data, then using PET data. 3/42 patients were excluded from the analysis (two with negative PET results, one with an extensive tumour, not precisely delineable by MRI or PET/CT). The average GTV{sub CT/MRI} was 22({+-}19)cm{sup 3}; GTV{sub PET} was 23({+-}20)cm{sup 3}. Additional GTV, obtained as a result of PET was 9({+-}10)cm{sup 3} and was observed in patients with osseous infiltration. In some pre-treated patients there were intratumoural areas (as identified in CT/MRI) without SR-expression (7({+-}11)cm{sup 3}). Common GTV as obtained by both CT/MRI and PET was 15({+-}14)cm{sup 3}. The mean bi-directional difference between the GTV{sub CT/MRI} and GTV{sub PET} accounted to 16({+-}15)cm{sup 3} (93%, p < 0.001). In a subgroup of seven patients with multiple meningiomas, PET showed a total of 19 lesions; nine of them were not recognizable by CT or MRI. {sup 68}Ga-DOTATOC-PET enables delineation of SR-positive meningiomas and delivers additional information to both CT and MRI regarding the planning of stereotactic radiotherapy. The acquisition on a PET/CT scanner helps to estimate the relation of PET findings to anatomical structures and is especially useful for detection of osseous infiltration

  1. A high-precision system for conformal intracranial radiotherapy

    International Nuclear Information System (INIS)

    Tome, Wolfgang A.; Meeks, Sanford L.; Buatti, John M.; Bova, Francis J.; Friedman, William A.; Li Zuofeng

    2000-01-01

    Purpose: Currently, optimally precise delivery of intracranial radiotherapy is possible with stereotactic radiosurgery and fractionated stereotactic radiotherapy. We report on an optimally precise optically guided system for three-dimensional (3D) conformal radiotherapy using multiple noncoplanar fixed fields. Methods and Materials: The optically guided system detects infrared light emitting diodes (IRLEDs) attached to a custom bite plate linked to the patient's maxillary dentition. The IRLEDs are monitored by a commercially available stereo camera system, which is interfaced to a personal computer. An IRLED reference is established with the patient at the selected stereotactic isocenter, and the computer reports the patient's current position based on the location of the IRLEDs relative to this reference position. Using this readout from the computer, the patient may be dialed directly to the desired position in stereotactic space. The patient is localized on the first day and a reference file is established for 5 different couch positions. The patient's image data are then imported into a commercial convolution-based 3D radiotherapy planning system. The previously established isocenter and couch positions are then used as a template upon which to design a conformal 3D plan with maximum beam separation. Results: The use of the optically guided system in conjunction with noncoplanar radiotherapy treatment planning using fixed fields allows the generation of highly conformal treatment plans that exhibit a high degree of dose homogeneity and a steep dose gradient. To date, this approach has been used to treat 28 patients. Conclusion: Because IRLED technology improves the accuracy of patient localization relative to the linac isocenter and allows real-time monitoring of patient position, one can choose treatment-field margins that only account for beam penumbra and image resolution without adding margin to account for larger and poorly defined setup uncertainty. This

  2. Vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis

    International Nuclear Information System (INIS)

    Liu, Eva Sau Fan; Wu, Vincent Wing Cheung; Harris, Benjamin; Foote, Matthew; Lehman, Margot; Chan, Lawrence Wing Chi

    2017-01-01

    Long planning time in volumetric-modulated arc stereotactic radiotherapy (VMA-SRT) cases can limit its clinical efficiency and use. A vector model could retrieve previously successful radiotherapy cases that share various common anatomic features with the current case. The prsent study aimed to develop a vector model that could reduce planning time by applying the optimization parameters from those retrieved reference cases. Thirty-six VMA-SRT cases of brain metastasis (gender, male [n = 23], female [n = 13]; age range, 32 to 81 years old) were collected and used as a reference database. Another 10 VMA-SRT cases were planned with both conventional optimization and vector-model-supported optimization, following the oncologists' clinical dose prescriptions. Planning time and plan quality measures were compared using the 2-sided paired Wilcoxon signed rank test with a significance level of 0.05, with positive false discovery rate (pFDR) of less than 0.05. With vector-model-supported optimization, there was a significant reduction in the median planning time, a 40% reduction from 3.7 to 2.2 hours (p = 0.002, pFDR = 0.032), and for the number of iterations, a 30% reduction from 8.5 to 6.0 (p = 0.006, pFDR = 0.047). The quality of plans from both approaches was comparable. From these preliminary results, vector-model-supported optimization can expedite the optimization of VMA-SRT for brain metastasis while maintaining plan quality.

  3. Vector-model-supported optimization in volumetric-modulated arc stereotactic radiotherapy planning for brain metastasis

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Eva Sau Fan [Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane (Australia); Department of Health Technology and Informatics, The Hong Kong Polytechnic University (Hong Kong); Wu, Vincent Wing Cheung [Department of Health Technology and Informatics, The Hong Kong Polytechnic University (Hong Kong); Harris, Benjamin [Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane (Australia); Foote, Matthew; Lehman, Margot [Department of Radiation Oncology, Princess Alexandra Hospital, Brisbane (Australia); School of Medicine, University of Queensland (Australia); Chan, Lawrence Wing Chi, E-mail: wing.chi.chan@polyu.edu.hk [Department of Health Technology and Informatics, The Hong Kong Polytechnic University (Hong Kong)

    2017-07-01

    Long planning time in volumetric-modulated arc stereotactic radiotherapy (VMA-SRT) cases can limit its clinical efficiency and use. A vector model could retrieve previously successful radiotherapy cases that share various common anatomic features with the current case. The prsent study aimed to develop a vector model that could reduce planning time by applying the optimization parameters from those retrieved reference cases. Thirty-six VMA-SRT cases of brain metastasis (gender, male [n = 23], female [n = 13]; age range, 32 to 81 years old) were collected and used as a reference database. Another 10 VMA-SRT cases were planned with both conventional optimization and vector-model-supported optimization, following the oncologists' clinical dose prescriptions. Planning time and plan quality measures were compared using the 2-sided paired Wilcoxon signed rank test with a significance level of 0.05, with positive false discovery rate (pFDR) of less than 0.05. With vector-model-supported optimization, there was a significant reduction in the median planning time, a 40% reduction from 3.7 to 2.2 hours (p = 0.002, pFDR = 0.032), and for the number of iterations, a 30% reduction from 8.5 to 6.0 (p = 0.006, pFDR = 0.047). The quality of plans from both approaches was comparable. From these preliminary results, vector-model-supported optimization can expedite the optimization of VMA-SRT for brain metastasis while maintaining plan quality.

  4. Pain relief by Cyberknife radiosurgery for spinal metastasis.

    Science.gov (United States)

    Lee, Sunyoung; Chun, Mison

    2012-01-01

    To report pain relief effect in patients with spinal metastases treated with Cyberknife® and to analyze the factors associated with pain relapse after initial pain relief. We retrospectively analyzed patients with spinal metastasis treated with stereotactic body radiosurgery between April 2007 and June 2009. A total of 57 patients with 73 lesions were available for analysis with a median follow-up of 6.8 months (range, 1-30). Pain was assessed by a verbal/visual analogue scale at each visit: from 0 to 10. Pain relief was defined as a decrease of at least three levels of the pain score without an increase in analgesic use. Complete relief was defined as no analgesics or a score 0 or 1. Pain relief was achieved in 88% of the lesions, with complete relief in 51% within 7 days from the start of radiosurgery. The median duration of pain relief was 3.2 months (range, 1-30). Pain reappeared in 16 patients (27%). Spinal cord compression (P = 0.001) and performance status (P = 0.01) were predictive of pain relapse by multivariate Cox analysis. All 6 patients treated with solitary spinal metastasis experienced pain relief; 5 of them were alive without evidence of disease at a median of 16 months (range, 7-30). As previous studies have shown, our study confirms that pain relief with spinal radiosurgery is around 90%. In particular, long-term pain relief and disease control was observed in patients with solitary spinal metastasis.

  5. Conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas

    International Nuclear Information System (INIS)

    Fuss, Martin; Debus, Juergen; Lohr, Frank; Huber, Peter; Rhein, Bernhard; Engenhart-Cabillic, Rita; Wannenmacher, Michael

    2000-01-01

    Purpose: Analysis of local tumor control and functional outcome following conventionally fractionated stereotactic radiotherapy (FSRT) for acoustic neuromas. Patients and Methods: From 11/1989 to 9/1999 51 patients with acoustic neuromas have been treated by FSRT. Mean total dose was 57.6 ± 2.5 Gy. Forty-two patients have been followed for at least 12 months and were subject of an outcome analysis. Mean follow-up was 42 months. We analyzed local control, hearing preservation, and facial and trigeminal nerve functional preservation. We evaluated influences of tumor size, age, and association with neurofibromatosis Type 2 (NF2) on outcome and treatment related toxicity. Results: Actuarial 2- and 5-year tumor control rates were 100% and 97.7%, respectively. Actuarial useful hearing preservation rate was 85% at 2 and 5 years. New hearing loss was diagnosed in 4 NF2 patients. Pretreatment normal facial nerve function was preserved in all cases. Two cases of new or impaired trigeminal nerve dysesthesia required medication. No other cranial nerve deficit was observed. In Patients without NF2 tumor size or age had no influence on tumor control and cranial nerve toxicity. Diagnosis of NF2 was associated with higher risk of hearing impairment (p 0.0002), the hearing preservation rate in this subgroup was 60%. Conclusion: FSRT has been shown to be an effective means of local tumor control. Excellent hearing preservation rates and 5th and 7th nerve functional preservation rates were achieved. The results support the conclusion that FSRT can be recommended to patients with acoustic neuromas where special attention has to be taken to preserve useful hearing and normal cranial nerve function. For NF2 patients, FSRT may be the treatment of choice with superior functional outcome compared to treatment alternatives.

  6. Setup uncertainties: consequences for multi-isocentre stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Ebert, M.A.; Harper, C.S.

    2000-01-01

    Full text: Beam data for use in dose calculations by planning systems is generally measured under static and controlled conditions. Yet, patient motion and setup uncertainties will effectively blur the resulting dose distributions leading to a discrepancy between planned and delivered dose distributions. This is particularly so for stereotactic radiotherapy where small well-defined fields are used. When multiple isocentres are used (possibly for larger irregular lesions), relative motion of isocentres due to setup variations may have deleterious effects on the intended radiation delivery. The influence of setup uncertainties was examined by performing a three-dimensional convolution of measured off-axis ratio (OAR) data with a Maxwellian distribution, with standard deviations representing several feasible levels of inaccuracy in patient setup. A sample of patient plans (predominantly multi-isocentre plans) were then considered using original (measured) OAR data, and then modified data in order to observe the resulting effect. The effect of systematic localisation error was also considered by examining resulting DVHs as isocentres were shifted by fixed amounts. In all cases considered, the maximum dose varied quite minimally with increase in setup error with the variation decreasing with increasing high-dose volume. The minimum dose however varied more significantly, and this has serious consequences for dose prescription as the minimum dose can be the controlling factor in treatment efficacy. For multi-isocentre plans, the degree of non-uniformity generated by setup error was not as significant as originally expected. This is in part due to the non-uniformity already present in such plans to begin with. Through incorporation of the effect of setup error into planning data, the influence of setup variations on dose distributions for multi-isocentre treatments has been determined. This influence should be considered when creating plans based on the level of spatial

  7. Adaptive fractionated stereotactic Gamma Knife radiotherapy of meningioma using integrated stereotactic cone-beam-CT and adaptive re-planning (a-gkFSRT)

    Energy Technology Data Exchange (ETDEWEB)

    Stieler, F.; Wenz, F.; Abo-Madyan, Y.; Schweizer, B.; Polednik, M.; Herskind, C.; Giordano, F.A.; Mai, S. [University of Heidelberg, Department of Radiation Oncology, University Medical Center Mannheim, Mannheim (Germany)

    2016-11-15

    The Gamma Knife Icon (Elekta AB, Stockholm, Sweden) allows frameless stereotactic treatment using a combination of cone beam computer tomography (CBCT), a thermoplastic mask system, and an infrared-based high-definition motion management (HDMM) camera system for patient tracking during treatment. We report on the first patient with meningioma at the left petrous bone treated with adaptive fractionated stereotactic radiotherapy (a-gkFSRT). The first patient treated with Gamma Knife Icon at our institute received MR imaging for preplanning before treatment. For each treatment fraction, a daily CBCT was performed to verify the actual scull/tumor position. The system automatically adapted the planned shot positions to the daily position and recalculated the dose distribution (online adaptive planning). During treatment, the HDMM system recorded the intrafractional patient motion. Furthermore, the required times were recorded to define a clinical treatment slot. Total treatment time was around 20 min. Patient positioning needed 0.8 min, CBCT positioning plus acquisition 1.65 min, CT data processing and adaptive planning 2.66 min, and treatment 15.6 min. The differences for the five daily CBCTs compared to the reference are for rotation: -0.59 ± 0.49 /0.18 ± 0.20 /0.05 ± 0.36 and for translation: 0.94 ± 0.52 mm/-0.08 ± 0.08 mm/-1.13 ± 0.89 mm. Over all fractions, an intrafractional movement of 0.13 ± 0.04 mm was observed. The Gamma Knife Icon allows combining the accuracy of the stereotactic Gamma Knife system with the flexibility of fractionated treatment with the mask system and CBCT. Furthermore, the Icon system introduces a new online patient tracking system to the clinical routine. The interfractional accuracy of patient positioning was controlled with a thermoplastic mask and CBCT. (orig.) [German] Das Gamma Knife Icon (Elekta AB, Stockholm, Schweden) ermoeglicht die stereotaktische Behandlung von Patienten mittels Cone-beam-Computertomographie (CBCT

  8. Multi-dimensional dosimetric verification of stereotactic radiotherapy for uveal melanoma using radiochromic EBT film

    International Nuclear Information System (INIS)

    Sturtewagen, E.; Fuss, M.; Georg, D.; Paelinck, L.; Wagter, C. de

    2008-01-01

    Since 1997, linac based stereotactic radiotherapy (SRT) of uveal melanoma has been continuously developed at the Department of Radiotherapy, Medical University Vienna. The aim of the present study was (i) to test a new type of radiochromic film (Gafchromic EBT) for dosimetric verification of class solutions for these treatments and (ii) to verify treatment plan acceptance criteria, which are based on gamma values statisitcs. An EPSON Expression 1680 Pro flat bed scanner was utilized for film reading. To establish a calibration curve, films were cut in squares of 2 x 2 cm 2 , positioned at 5 cm depth in a solid water phantom and were irradiated with different dose levels (0.5 and 5 Gy) in a 5 x 5 cm 2 field at 6 MV. A previously developed solid phantom (polystyrene) was used with overall dimensions corresponding to an average human head. EBT films were placed at four different depths (10, 20, 25 and 30 mm) and all films were irradiated simultaneously. Four different treatment plans were verified that resemble typical clinical situations. These plans differed in irradiation technique (conformal mMLC or circular arc SRT) and in tumour size (PTV of 1 or 2.5 cm 3 ). In-house developed software was applied to calculate gamma (γ) index values and to perform several statistical operations (e.g. γ-area histograms). At depths of 10 mm γ 1% (γ-value where 1% of the points have an equal or higher value in the region of interest) were between 1-3 and maximum γ > 1 (% of γ-values > 1 in the region of interest) areas were almost 30%. At larger depths, i.e. more close to the isocenter, γ 1% was > 1 areas were mostly < 5%. Average γ values were about 0.5. Besides the compromised accuracy in the buildup region, previously defined IMRT acceptance criteria [Stock et al., Phys. Med. Biol. 50 (2005) 399-411] could be applied as well to SRT. Radiochromic EBT films, in combination with a flat-bed scanner, were found to be an ideal multidimensional dosimetric tool for treatment

  9. Factors Influencing Neurocognitive Outcomes in Young Patients With Benign and Low-Grade Brain Tumors Treated With Stereotactic Conformal Radiotherapy

    International Nuclear Information System (INIS)

    Jalali, Rakesh; Mallick, Indranil; Dutta, Debnarayan

    2010-01-01

    Purpose: To present the effect of radiotherapy doses to different volumes of normal structures on neurocognitive outcomes in young patients with benign and low-grade brain tumors treated prospectively with stereotactic conformal radiotherapy (SCRT). Methods and Materials: Twenty-eight patients (median age, 13 years) with residual/progressive brain tumors (10 craniopharyngioma, 8 cerebellar astrocytoma, 6 optic pathway glioma and 4 cerebral low-grade glioma) were treated with SCRT to a dose of 54 Gy in 30 fractions over 6 weeks. Prospective neuropsychological assessments were done at baseline before RT and at subsequent follow-up examinations. The change in intelligence quotient (IQ) scores was correlated with various factors, including dose-volume to normal structures. Results: Although the overall mean full-scale IQ (FSIQ) at baseline before RT remained unchanged at 2-year follow-up after SCRT, one third of patients did show a >10% decline in FSIQ as compared with baseline. Logistic regression analysis demonstrated that patients aged 10% drop in FSIQ than older patients (53% vs. 10%, p = 0.03). Dosimetric comparison in patients showing a >10% decline vs. patients showing a 43.2 Gy to >13% of volume of the left temporal lobe were the ones to show a significant drop in FSIQ (p = 0.048). Radiotherapy doses to other normal structures, including supratentorial brain, right temporal lobe, and frontal lobes, did not reveal any significant correlation. Conclusion: Our prospectively collected dosimetric data show younger age and radiotherapy doses to left temporal lobe to be predictors of neurocognitive decline, and may well be used as possible dose constraints for high-precision radiotherapy planning.

  10. Potential of image-guidance, gating and real-time tracking to improve accuracy in pulmonary stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Krieger, Thomas; Richter, Anne; Baier, Kurt; Wilbert, Juergen; Sweeney, Reinhart A.; Flentje, Michael

    2009-01-01

    Purpose: To evaluate the potential of image-guidance, gating and real-time tumor tracking to improve accuracy in pulmonary stereotactic body radiotherapy (SBRT). Materials and methods: Safety margins for compensation of inter- and intra-fractional uncertainties of the target position were calculated based on SBRT treatments of 43 patients with pre- and post-treatment cone-beam CT imaging. Safety margins for compensation of breathing motion were evaluated for 17 pulmonary tumors using respiratory correlated CT, model-based segmentation of 4D-CT images and voxel-based dose accumulation; the target in the mid-ventilation position was the reference. Results: Because of large inter-fractional base-line shifts of the tumor, stereotactic patient positioning and image-guidance based on the bony anatomy required safety margins of 12 mm and 9 mm, respectively. Four-dimensional image-guidance targeting the tumor itself and intra-fractional tumor tracking reduced margins to <5 mm and <3 mm, respectively. Additional safety margins are required to compensate for breathing motion. A quadratic relationship between tumor motion and margins for motion compensation was observed: safety margins of 2.4 mm and 6 mm were calculated for compensation of 10 mm and 20 mm motion amplitudes in cranio-caudal direction, respectively. Conclusion: Four-dimensional image-guidance with pre-treatment verification of the target position and online correction of errors reduced safety margins most effectively in pulmonary SBRT.

  11. [The need for a paradigm shift in radiotherapy].

    Science.gov (United States)

    Mayer, Árpád; Katona, Csilla; Farkas, Róbert; Póti, Zsuzsa

    2015-11-01

    The status and indications of radiotherapy have significantly changed in the past decade because novel techniques, radiobiological research and major advances in informatics have made better local control possible. Using supplemented marking of the target volume with computer tomography based other image-making methods adapted made it possible to define the tumor and intact surrounding tissues more precisely. With novel radiotherapy techniques the dosage of the homogenity and the covering in the target volume can be raised optimally, especially with intensity modulated arc radiotherapy (volumetric modulated arc therapy) without causing radiation injury or damage to intact surrounding tissues. Furthermore, with novel techniques and target volume marking, new indications have appeared in clinical practice and besides stereotactic radiotherapy for intracranial metastases, the extracranial so-called oligometastic conditions can be maintained close to a curative state (or in remission) for many years. Among these, perhaps the most striking is the stereotactic radiotherapy treatment of liver, lung and spinal cord metastases in one or more fractions, for which the indispensable condition is the image or respiratory guided technique.

  12. Clinical outcome of stereotactic body radiotherapy of 54 Gy in nine fractions for patients with localized lung tumor using a custom-made immobilization system

    International Nuclear Information System (INIS)

    Aoki, Masahiko; Abe, Yoshinao; Kondo, Hidehiro

    2007-01-01

    The aim of this study was to investigate the clinical outcome of stereotactic body radiotherapy (SBRT) of 54 Gy in nine fractions for patients with localized lung tumor using a custom-made immobilization system. The subjects were 19 patients who had localized lung tumor (11 primaries, 8 metastases) between May 2003 and October 2005. Treatment was conducted on 19 lung tumors by fixed multiple noncoplanar conformal beams with a standard linear accelerator. The isocentric dose was 54 Gy in nine fractions. The median overall treatment time was 15 days (range 11-22 days). All patients were immobilized by a thermo-shell and a custom-made headrest during the treatment. The crude local tumor control rate was 95% during the follow-up of 9.4-39.5 (median 17.7) months. In-field recurrence was noted in only one patient at the last follow-up. The Kaplan-Meier overall survival rate at 2 years was 89.5%. Grade 1 radiation pneumonia and grade 1 radiation fibrosis were observed in 12 of the 19 patients. Treatment-related severe early and late complications were not observed in this series. The stereotactic body radiotherapy of 54 Gy in nine fractions achieved acceptable tumor control without any severe complications. The results suggest that SBRT can be one of the alternatives for patients with localized lung tumors. (author)

  13. Chest Wall Volume Receiving >30 Gy Predicts Risk of Severe Pain and/or Rib Fracture After Lung Stereotactic Body Radiotherapy

    International Nuclear Information System (INIS)

    Dunlap, Neal E.; Cai, Jing; Biedermann, Gregory B.; Yang, Wensha; Benedict, Stanley H.; Sheng Ke; Schefter, Tracey E.; Kavanagh, Brian D.; Larner, James M.

    2010-01-01

    Purpose: To identify the dose-volume parameters that predict the risk of chest wall (CW) pain and/or rib fracture after lung stereotactic body radiotherapy. Methods and Materials: From a combined, larger multi-institution experience, 60 consecutive patients treated with three to five fractions of stereotactic body radiotherapy for primary or metastatic peripheral lung lesions were reviewed. CW pain was assessed using the Common Toxicity Criteria for pain. Peripheral lung lesions were defined as those located within 2.5 cm of the CW. A minimal point dose of 20 Gy to the CW was required. The CW volume receiving ≥20, ≥30, ≥40, ≥50, and ≥60 Gy was determined and related to the risk of CW toxicity. Results: Of the 60 patients, 17 experienced Grade 3 CW pain and five rib fractures. The median interval to the onset of severe pain and/or fracture was 7.1 months. The risk of CW toxicity was fitted to the median effective concentration dose-response model. The CW volume receiving 30 Gy best predicted the risk of severe CW pain and/or rib fracture (R 2 = 0.9552). A volume threshold of 30 cm 3 was observed before severe pain and/or rib fracture was reported. A 30% risk of developing severe CW toxicity correlated with a CW volume of 35 cm 3 receiving 30 Gy. Conclusion: The development of CW toxicity is clinically relevant, and the CW should be considered an organ at risk in treatment planning. The CW volume receiving 30 Gy in three to five fractions should be limited to 3 , if possible, to reduce the risk of toxicity without compromising tumor coverage.

  14. Extracranial Facial Nerve Schwannoma Treated by Hypo-fractionated CyberKnife Radiosurgery.

    Science.gov (United States)

    Sasaki, Ayaka; Miyazaki, Shinichiro; Hori, Tomokatsu

    2016-09-21

    Facial nerve schwannoma is a rare intracranial tumor. Treatment for this benign tumor has been controversial. Here, we report a case of extracranial facial nerve schwannoma treated successfully by hypo-fractionated CyberKnife (Accuray, Sunnyvale, CA) radiosurgery and discuss the efficacy of this treatment. A 34-year-old female noticed a swelling in her right mastoid process. The lesion enlarged over a seven-month period, and she experienced facial spasm on the right side. She was diagnosed with a facial schwannoma via a magnetic resonance imaging (MRI) scan of the head and neck and was told to wait until the facial nerve palsy subsides. She was referred to our hospital for radiation therapy. We planned a fractionated CyberKnife radiosurgery for three consecutive days. After CyberKnife radiosurgery, the mass in the right parotid gradually decreased in size, and the facial nerve palsy disappeared. At her eight-month follow-up, her facial spasm had completely disappeared. There has been no recurrence and the facial nerve function has been normal. We successfully demonstrated the efficacy of CyberKnife radiosurgery as an alternative treatment that also preserves neurofunction for facial nerve schwannomas.

  15. Stereotactic Radiotherapy of Primary Lung Cancer and Other Targets: Results of Consultant Meeting of the International Atomic Energy Agency

    International Nuclear Information System (INIS)

    Nagata, Yasushi; Wulf, Joern; Lax, Ingmar; Timmerman, Robert; Zimmermann, Frank; Stojkovski, Igor; Jeremic, Branislav

    2011-01-01

    To evaluate the current status of stereotactic body radiotherapy (SBRT) and identify both advantages and disadvantages of its use in developing countries, a meeting composed of consultants of the International Atomic Energy Agency was held in Vienna in November 2006. Owing to continuous developments in the field, the meeting was extended by subsequent discussions and correspondence (2007-2010), which led to the summary presented here. The advantages and disadvantages of SBRT expected to be encountered in developing countries were identified. The definitions, typical treatment courses, and clinical results were presented. Thereafter, minimal methodology/technology requirements for SBRT were evaluated. Finally, characteristics of SBRT for developing countries were recommended. Patients for SBRT should be carefully selected, because single high-dose radiotherapy may cause serious complications in some serial organs at risk. Clinical experiences have been reported in some populations of lung cancer, lung oligometastases, liver cancer, pancreas cancer, and kidney cancer. Despite the disadvantages expected to be experienced in developing countries, SBRT using fewer fractions may be useful in selected patients with various extracranial cancers with favorable outcome and low toxicity.

  16. Radiotherapy

    International Nuclear Information System (INIS)

    Wannenmacher, M.; Debus, J.; Wenz, F.

    2006-01-01

    The book is focussed on the actual knowledge on the clinical radiotherapy and radio-oncology. Besides fundamental and general contributions specific organ systems are treated in detail. The book contains the following contributions: Basic principles, radiobiological fundamentals, physical background, radiation pathology, basics and technique of brachytherapy, methodology and technique of the stereotactic radiosurgery, whole-body irradiation, operative radiotherapy, hadron therapy, hpyerthermia, combined radio-chemo-therapy, biometric clinical studies, intensity modulated radiotherapy, side effects, oncological diagnostics; central nervous system and sense organs, head-neck carcinomas, breast cancer, thorax organs, esophagus carcinoma, stomach carcinoma, pancreas carcinoma, heptabiliary cancer and liver metastases, rectal carcinomas, kidney and urinary tract, prostate carcinoma, testicular carcinoma, female pelvis, lymphatic system carcinomas, soft tissue carcinoma, skin cancer, bone metastases, pediatric tumors, nonmalignant diseases, emergency in radio-oncology, supporting therapy, palliative therapy

  17. Quality assurance procedure for assessing mechanical accuracy of a radiation field center in stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Tatsumi, Daisaku; Ienaga, Akinori; Nakada, Ryosei; Yomoda, Akane; Inoue, Makoto; Ichida, Takao; Hosono, Masako

    2012-01-01

    Stereotactic radiotherapy requires a quality assurance (QA) program that ensures the mechanical accuracy of a radiation field center. We have proposed a QA method for achieving the above requirement by conducting the Winston Lutz test using an electronic portal image device (EPID). An action limit was defined as three times the standard deviation. Then, the action limits for mean deviations of the radiation field center during collimator rotation, gantry rotation, and couch rotation in clockwise and counterclockwise resulted in 0.11 mm, 0.52 mm, 0.37 mm, and 0.41 mm respectively. Two years after the QA program was launched, the mean deviation of the radiation field center during gantry rotation exceeded the above action limit. Consequently, a mechanical adjustment for the gantry was performed, thereby restoring the accuracy of the radiation field center. A field center shift of 0.5 mm was also observed after a micro multi-leaf collimator was unmounted. (author)

  18. Role of external radiotherapy when taking into care hepatic metastases; Place de la radiotherapie externe dans la prise en charge des metastases hepatiques

    Energy Technology Data Exchange (ETDEWEB)

    Dietmann, A.S.; Taste-Geroge, H.; Peiffert, D. [Centre Alexis-Vautrin, 54 - Nancy (France)

    2010-10-15

    After having indicated the various origins of hepatic metastases, the authors outline that surgery and local treatment are applicable for 20 per cent of patients. But some of these local treatments may have contra-indications or may entail complications. Radiotherapy techniques used to have possible severe late effects on the liver, but new external radiotherapy apparatus, like the Cyberknife, can now be used. With its ballistic technique and its tracking system, it allows healthy tissues to be protected. It is also well tolerated by the patients. A comparative study with other local treatment techniques (radio-frequency, alcoolization, chemoembolisation) is still to be done. Short communication

  19. Performance of a Novel Repositioning Head Frame for Gamma Knife Perfexion and Image-Guided Linac-Based Intracranial Stereotactic Radiotherapy

    International Nuclear Information System (INIS)

    Ruschin, Mark; Nayebi, Nazanin; Carlsson, Per; Brown, Kevin

    2010-01-01

    Purpose: To evaluate the geometric positioning and immobilization performance of a vacuum bite-block repositioning head frame (RHF) system for Perfexion (PFX-SRT) and linac-based intracranial image-guided stereotactic radiotherapy (SRT). Methods and Materials: Patients with intracranial tumors received linac-based image-guided SRT using the RHF for setup and immobilization. Three hundred thirty-three fractions of radiation were delivered in 12 patients. The accuracy of the RHF was estimated for linac-based SRT with online cone-beam CT (CBCT) and for PFX-SRT with a repositioning check tool (RCT) and offline CBCT. The RCT's ability to act as a surrogate for anatomic position was estimated through comparison to CBCT image matching. Immobilization performance was evaluated daily with pre- and postdose delivery CBCT scans and RCT measurements. Results: The correlation coefficient between RCT- and CBCT-reported displacements was 0.59, 0.75, 0.79 (Right, Superior, and Anterior, respectively). For image-guided linac-based SRT, the mean three-dimensional (3D) setup error was 0.8 mm with interpatient (Σ) and interfraction (σ) variations of 0.1 and 0.4 mm, respectively. For PFX-SRT, the initial, uncorrected mean 3D positioning displacement in stereotactic coordinates was 2.0 mm, with Σ = 1.1 mm and σ = 0.8 mm. Considering only RCT setups o in pitch. The mean 3D intrafraction motion was 0.4 ± 0.3 mm. Conclusion: The RHF provides excellent immobilization for intracranial SRT and PFX-SRT. Some small systematic uncertainties in stereotactic positioning exist and must be considered when generating PFX-SRT treatment plans. The RCT provides reasonable surrogacy for internal anatomic displacement.

  20. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    International Nuclear Information System (INIS)

    Jung, Jinhong; Song, Si Yeol; Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun; Choi, Wonsik; Jeong, Seong-Yun; Choi, Eun Kyung; Cho, Byungchul

    2015-01-01

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors

  1. Verification of Accuracy of CyberKnife Tumor-tracking Radiation Therapy Using Patient-specific Lung Phantoms

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Jinhong [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Department of Radiation Oncology, Kyung Hee University Medical Center, Kyung Hee University School of Medicine, Seoul (Korea, Republic of); Song, Si Yeol, E-mail: coocoori@gmail.com [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Yoon, Sang Min; Kwak, Jungwon; Yoon, KyoungJun [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Wonsik [Department of Radiation Oncology, Gangneung Asan Hospital, University of Ulsan College of Medicine, Gangneung (Korea, Republic of); Jeong, Seong-Yun [Asan Institute for Life Science, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of); Choi, Eun Kyung; Cho, Byungchul [Department of Radiation Oncology, Asan Medical Center, University of Ulsan College of Medicine, Seoul (Korea, Republic of)

    2015-07-15

    Purpose: To investigate the accuracy of the CyberKnife Xsight Lung Tracking System (XLTS) compared with that of a fiducial-based target tracking system (FTTS) using patient-specific lung phantoms. Methods and Materials: Three-dimensional printing technology was used to make individualized lung phantoms that closely mimicked the lung anatomy of actual patients. Based on planning computed tomographic data from 6 lung cancer patients who underwent stereotactic ablative radiation therapy using the CyberKnife, the volume above a certain Hounsfield unit (HU) was assigned as the structure to be filled uniformly with polylactic acid material by a 3-dimensional printer (3D Edison, Lokit, Korea). We evaluated the discrepancies between the measured and modeled target positions, representing the total tracking error, using 3 log files that were generated during each treatment for both the FTTS and the XLTS. We also analyzed the γ index between the film dose measured under the FTTS and XLTS. Results: The overall mean values and standard deviations of total tracking errors for the FTTS were 0.36 ± 0.39 mm, 0.15 ± 0.64 mm, and 0.15 ± 0.62 mm for the craniocaudal (CC), left–right (LR), and anteroposterior (AP) components, respectively. Those for the XLTS were 0.38 ± 0.54 mm, 0.13 ± 0.18 mm, and 0.14 ± 0.37 mm for the CC, LR, and AP components, respectively. The average of γ passing rates was 100% for the criteria of 3%, 3 mm; 99.6% for the criteria of 2%, 2 mm; and 86.8% for the criteria of 1%, 1 mm. Conclusions: The XLTS has segmentation accuracy comparable with that of the FTTS and small total tracking errors.

  2. Hypofractionated stereotactic photon radiotherapy of posteriorly located choroidal melanoma with five fractions at ten Gy – Clinical results after six years of experience

    International Nuclear Information System (INIS)

    Dunavoelgyi, Roman; Zehetmayer, Martin; Gleiss, Andreas; Geitzenauer, Wolfgang; Kircher, Karl; Georg, Dietmar; Schmidt-Erfurth, Ursula; Poetter, Richard; Dieckmann, Karin

    2013-01-01

    Purpose: To evaluate long-term safety and efficacy of hypofractionated stereotactic photon radiotherapy with 5 five fractions at 10 Gy each in patients with centrally located choroidal melanoma. Materials and Methods: Ninety-one patients with centrally located choroidal melanoma were treated stereotactically at a linear accelerator with 6 MV photon beams with 5 fractions at 10 Gy each. Examinations were performed at baseline and every 3 months in the first 2 years, then every 6 months until 5 years and yearly thereafter. Median follow-up was 37.8 months (IQR 19.2–49.9). They included visual acuity assessment, routine ophthalmological examinations with fundoscopy, echography for measurement of tumor dimensions, medical examinations and, if necessary, fluorescein angiography. Results: Initial tumor base diameters, height and volume were 11.20 mm (IQR 9.10–13.70), 9.80 mm (IQR 7.80–11.70), 4.53 mm (IQR 3.33–6.43) and 253.8 mm 3 (IQR 127.5–477.0). Local tumor control and eye retention rates were 97.7% and 86.4% after 5 years, respectively. Eight patients developed metastatic disease and 3 of them died due to metastatic disease during the follow-up period. Median visual acuity decreased from 0.67 initially to 0.05 at the last individual follow-up (p < 0.001). The most common toxicities (any grade) were radiation retinopathy (n = 39), optic neuropathy (n = 32), radiogenic cataract (n = 21), neovascular glaucoma (n = 15) and dry eye syndrome (n = 10). The 5 year probabilities to remain free of these side effects (any grade) were 26.0%, 45.4%, 55.4%, 72.6% and 80.5%, respectively. The most important prognostic factors for toxicities were the largest tumor base diameter, tumor height and tumor distance to the optic disk. Conclusion: Hypofractionated stereotactic photon radiotherapy with a total dose of 50 Gy delivered in 5 fractions is a highly effective treatment option in patients with centrally located choroidal melanoma and has a moderate toxicity profile

  3. Severe Chest Wall Toxicity From Cryoablation in the Setting of Prior Stereotactic Ablative Radiotherapy.

    Science.gov (United States)

    Chaudhuri, Aadel A; Binkley, Michael S; Aggarwal, Sonya; Qian, Yushen; Carter, Justin N; Shah, Rajesh; Loo, Billy W

    2016-02-02

    We present the case of a 42-year-old woman with metastatic synovial sarcoma of parotid origin, treated definitively with chemoradiation, who subsequently developed oligometastatic disease limited to the lungs. She underwent multiple left and right lung wedge resections and left lower lobectomy, followed by right lower lobe stereotactic ablative radiotherapy (SABR), 54 Gy in three fractions to a right lower lobe lesion abutting the chest wall. Two years later, she was treated with cryoablation for a separate right upper lobe nodule abutting the chest wall. Two months later, she presented with acute shortness of breath, pleuritic chest pain, decreased peripheral blood O2 saturation, and productive cough. A computed tomography (CT) scan demonstrated severe chest wall necrosis in the area of recent cryoablation that, in retrospect, also received a significant radiation dose from her prior SABR. This case demonstrates that clinicians should exercise caution in using cryoablation when treating lung tumors abutting a previously irradiated chest wall. Note: Drs. Loo and Shah contributed equally as co-senior authors.

  4. Stereotactic Radiotherapy in the Treatment of Lung Metastases from Bone and Soft-tissue Sarcomas.

    Science.gov (United States)

    Frakulli, Rezarta; Salvi, Fabrizio; Balestrini, Damiano; Parisi, Alessandro; Palombarini, Marcella; Cammelli, Silvia; Rocca, Michele; Salone, Mariacristina; Longhi, Alessandra; Ferrari, Stefano; Morganti, Alessio G; Frezza, Giovanni

    2015-10-01

    The purpose of this study was to evaluate local control and toxicity in a group of patients treated with stereotactic body radiotherapy (SBRT) for lung metastases (LM) from bone and soft tissue sarcomas. From October 2010 to July 2014, patients with LM from sarcomas not suitable for surgery were treated with daily cone-beam computed tomography-guided SBRT. The dose administered ranged from 30 to 60 Gy in 3-8 fractions. Acute and late toxicity were scored according to Common Terminology Criteria for Adverse Events version 4.0. A total of 24 patients with 68 LM from sarcomas were treated with SBRT. The median follow-up after SBRT was 17 months (range=11-51 months). Two-year actuarial lesion local control and overall survival were 85.9% and 66.4%, respectively. No G3 or greater acute and late toxicities were observed. SBRT is a safe and effective treatment for LM from sarcoma and might be used as an alternative option in patients unfit for surgery. Copyright© 2015 International Institute of Anticancer Research (Dr. John G. Delinassios), All rights reserved.

  5. Peripheral dose measurement for CyberKnife radiosurgery with upgraded linac shielding

    International Nuclear Information System (INIS)

    Chuang, Cynthia F.; Larson, David A.; Zytkovicz, Andrea; Smith, Vernon; Petti, Paula L.

    2008-01-01

    The authors investigated the peripheral dose reduction for CyberKnife radiosurgery treatments after the installation of a linac shielding upgrade. As in a previous investigation, the authors considered two treatment plans, one for a hypothetical target in the brain and another for a target in the thorax, delivered to an anthropomorphic phantom. The results of the prior investigation showed that the CyberKnife delivered significantly higher peripheral doses than comparable model C Gamma Knife or IMRT treatments. Current measurements, after the linac shielding upgrade, demonstrate that the additional shielding decreased the peripheral dose, expressed as a percentage of the delivered monitor units (MU), by a maximum of 59%. The dose reduction was greatest for cranial-caudal distances from the field edge less than 30 cm, and at these distances, the CyberKnife peripheral dose, expressed as a percentage of the delivered MU, is now comparable to that measured for the other treatment modalities in our previous investigation. For distances between 30 and 70 cm from the field edge, the additional shielding reduced the peripheral dose by between 20% and 55%. At these distances, the CyberKnife peripheral dose remains higher than doses measured in our previous study for the model C Gamma Knife and IMRT

  6. Clinical characteristics and outcome of pneumothorax after stereotactic body radiotherapy for lung tumors.

    Science.gov (United States)

    Asai, Kaori; Nakamura, Katsumasa; Shioyama, Yoshiyuki; Sasaki, Tomonari; Matsuo, Yoshio; Ohga, Saiji; Yoshitake, Tadamasa; Terashima, Kotaro; Shinoto, Makoto; Matsumoto, Keiji; Hirata, Hidenari; Honda, Hiroshi

    2015-12-01

    We retrospectively investigated the clinical characteristics and outcome of pneumothorax after stereotactic body radiotherapy (SBRT) for lung tumors. Between April 2003 and July 2012, 473 patients with lung tumors were treated with SBRT. We identified 12 patients (2.5 %) with pneumothorax caused by SBRT, and evaluated the clinical features of pneumothorax. All of the tumors were primary lung cancers. The severity of radiation pneumonitis was grade 1 in 10 patients and grade 2 in two patients. Nine patients had emphysema. The planning target volume and pleura overlapped in 11 patients, and the tumors were attached to the pleura in 7 patients. Rib fractures were observed in three patients before or at the same time as the diagnosis of pneumothorax. The median time to onset of pneumothorax after SBRT was 18.5 months (4-84 months). The severity of pneumothorax was grade 1 in 11 patients and grade 3 in one patient. Although pneumothorax was a relatively rare late adverse effect after SBRT, some patients demonstrated pneumothorax after SBRT for peripheral lung tumors. Although most pneumothorax was generally tolerable and self-limiting, careful follow-up is needed.

  7. SU-F-T-566: Absolute Film Dosimetry for Stereotactic Radiosurgery and Stereotactic Body Radiotherapy Quality Assurance Using Gafchromic EBT3 Films

    Energy Technology Data Exchange (ETDEWEB)

    Wen, N; Lu, S; Qin, Y; Huang, Y; Zhao, B; Liu, C; Chetty, I [Henry Ford Health System, Detroit, MI (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric uncertainty associated with Gafchromic (EBT3) films and establish an absolute dosimetry protocol for Stereotactic Radiosurgery (SRS) and Stereotactic Body Radiotherapy (SBRT). Methods: EBT3 films were irradiated at each of seven different dose levels between 1 and 15 Gy with open fields, and standard deviations of dose maps were calculated at each color channel for evaluation. A scanner non-uniform response correction map was built by registering and comparing film doses to the reference diode array-based dose map delivered with the same doses. To determine the temporal dependence of EBT3 films, the average correction factors of different dose levels as a function of time were evaluated up to four days after irradiation. An integrated film dosimetry protocol was developed for dose calibration, calibration curve fitting, dose mapping, and profile/gamma analysis. Patient specific quality assurance (PSQA) was performed for 93 SRS/SBRT treatment plans. Results: The scanner response varied within 1% for the field sizes less than 5 × 5 cm{sup 2}, and up to 5% for the field sizes of 10 × 10 cm{sup 2}. The scanner correction method was able to remove visually evident, irregular detector responses found for larger field sizes. The dose response of the film changed rapidly (∼10%) in the first two hours and plateaued afterwards, ∼3% change between 2 and 24 hours. The mean uncertainties (mean of the standard deviations) were <0.5% over the dose range 1∼15Gy for all color channels for the OD response curves. The percentage of points passing the 3%/1mm gamma criteria based on absolute dose analysis, averaged over all tests, was 95.0 ± 4.2. Conclusion: We have developed an absolute film dose dosimetry protocol using EBT3 films. The overall uncertainty has been established to be approximately 1% for SRS and SBRT PSQA. The work was supported by a Research Scholar Grant, RSG-15-137-01-CCE from the American Cancer Society.

  8. Neuropsychological status in children and young adults with benign and low-grade brain tumors treated prospectively with focal stereotactic conformal radiotherapy

    International Nuclear Information System (INIS)

    Jalali, Rakesh; Goswami, Savita; Sarin, Rajiv; More, Niteen; Siddha, Manish; Kamble, Rashmi

    2006-01-01

    Purpose: To present prospective neuropsychological data at baseline and follow-up in children and young adults with benign and low-grade gliomas treated with focal stereotactic conformal radiotherapy (SCRT). Methods and Materials: A total of 22 patients (age 4-25 years) with residual/progressive benign and low-grade brain tumors considered suitable for SCRT underwent detailed and in-depth neuropsychological and cognitive testing at baseline before SCRT. The test battery included measurement of age-adjusted intelligence quotients (IQs) and cognitive parameters of visual, spatial, visuomotor, and attention concentrations. Anxiety was measured using the State-Trait Anxiety Inventory for Children and Hamilton Anxiety Rating Scale for patients >16 years old. Patients were treated with high-precision conformal radiotherapy under stereotactic guidance to a dose of 54 Gy in 30 fractions. All neuropsychological assessments were repeated at 6 and 24 months after SCRT completion and compared with the baseline values. Results: The baseline mean full-scale IQ before starting RT for patients 16 years, the corresponding value was 72 (range, 64-129). Of 20 evaluable patients, 14 (70%) had less than average IQs at baseline, even before starting radiotherapy. The verbal IQ, performance IQ, and full-scale IQ, as well as other cognitive scores, did not change significantly at the 6- and 24-month follow-up assessments for all patients. The memory quotient in older children and young adults was maintained at 6 and 24 months after SCRT, with a mean value of 93 and 100, respectively, compared with a mean baseline value of 81 before RT. The mean anxiety score in children measured by the C1 and C2 components of the State-Trait Anxiety Inventory for Children (STAIC) was 48 and 40, respectively, which improved significantly to mean values of 30 and 26, respectively, at the 24-month follow-up assessment (p = 0.005). The mean depression score in patients >16 years old was 23 at baseline and had

  9. Randomised phase I/II study to evaluate carbon ion radiotherapy versus fractionated stereotactic radiotherapy in patients with recurrent or progressive gliomas: The CINDERELLA trial

    International Nuclear Information System (INIS)

    Combs, Stephanie E; Wick, Wolfgang; Debus, Jürgen; Burkholder, Iris; Edler, Lutz; Rieken, Stefan; Habermehl, Daniel; Jäkel, Oliver; Haberer, Thomas; Haselmann, Renate; Unterberg, Andreas

    2010-01-01

    Treatment of patients with recurrent glioma includes neurosurgical resection, chemotherapy, or radiation therapy. In most cases, a full course of radiotherapy has been applied after primary diagnosis, therefore application of re-irradiation has to be applied cauteously. With modern precision photon techniques such as fractionated stereotactic radiotherapy (FSRT), a second course of radiotherapy is safe and effective and leads to survival times of 22, 16 and 8 months for recurrent WHO grade II, III and IV gliomas. Carbon ions offer physical and biological characteristics. Due to their inverted dose profile and the high local dose deposition within the Bragg peak precise dose application and sparing of normal tissue is possible. Moreover, in comparison to photons, carbon ions offer an increased relative biological effectiveness (RBE), which can be calculated between 2 and 5 depending on the GBM cell line as well as the endpoint analyzed. Protons, however, offer an RBE which is comparable to photons. First Japanese Data on the evaluation of carbon ion radiation therapy for the treatment of primary high-grade gliomas showed promising results in a small and heterogeneous patient collective. In the current Phase I/II-CINDERELLA-trial re-irradiation using carbon ions will be compared to FSRT applied to the area of contrast enhancement representing high-grade tumor areas in patients with recurrent gliomas. Within the Phase I Part of the trial, the Recommended Dose (RD) of carbon ion radiotherapy will be determined in a dose escalation scheme. In the subsequent randomized Phase II part, the RD will be evaluated in the experimental arm, compared to the standard arm, FSRT with a total dose of 36 Gy in single doses of 2 Gy. Primary endpoint of the Phase I part is toxicity. Primary endpoint of the randomized part II is survival after re-irradiation at 12 months, secondary endpoint is progression-free survival. The Cinderella trial is the first study to evaluate carbon ion

  10. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    International Nuclear Information System (INIS)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K

    2015-01-01

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003

  11. SU-E-T-767: Treatment Planning Study of Prostate Cancer by CyberKnife with Respect to the Urethral Dose

    Energy Technology Data Exchange (ETDEWEB)

    Mizuno, H; Mizuno, H; Sumida, I; Otani, Y; Yagi, M; Takashina, M; Suzuki, O; Yoshioka, Y; Koizumi, M; Ogawa, K [Osaka University, Suita, Osaka (Japan)

    2015-06-15

    Purpose: Hypo-fractionated stereotactic body radiation therapy (SBRT) with intensity modulated radiation therapy (IMRT) is nowadays one of the treatment strategies for prostate cancer. There are few reports on planning study of prostate cancer by CyberKnife with respect to the urethral dose because of the invisibility in CT. We have investigated a planning method using fixed collimators with considering dose homogeneity, conformity and urethral dose. Methods: Radiotherapy treatment planning of prostate cancer were under a clinical trial approved by the institutional review board. The prescription dose of 35 Gy were delivered to the PTV in five fractions with the urethral catheter. Urethra position was identified by pretreatment CT and catheter, which was inserted before treatment planning CT and released after the treatment. All plans agreed to the criteria as shown in table 1, and the following constraints were recommended as well: the prescribed iso-dose line should be from 70% to 90%; the total MU should be below 50,000 MU; the minimum MU per beam should be larger than 15 MU; the estimated delivery time (excluding patient setup time) by Multiplan with image time interval of 60 s should be less than 35 min. Collimator size and position were decided as shown in figure 1. Fixed collimator of 15 mm was positioned around urethra and PTV for avoiding high dose of urethra and achieving conformity, and fixed collimator of 30 or 40 were positioned around PTV for achieving dose homogeneity. Results: With this method, all constraints were achieved. (Table 1, Figure 2) Max dose of urethra was ranging from 103.9% to 114.2%, because urethra position was identified by pretreatment CT and urethral catheter. Conclusion: Hypo-fractionated SBRT with IMRT utilizing urethral catheter could be a promising new treatment option for prostate cancer. This work was supported by JSPS Core-to-Core program Number 23003.

  12. Stereotactic radiotherapy of meningiomas compressing optical pathways

    International Nuclear Information System (INIS)

    Hamm, Klaus-Detlef; Henzel, Martin; Gross, Markus W.; Surber, Gunnar; Kleinert, Gabriele; Engenhart-Cabillic, Rita

    2006-01-01

    Purpose: Microsurgical resection is usually the treatment of choice for meningiomas, especially for those that compress the optical pathways. However, in many cases of skull-base meningiomas a high risk of neurological deficits and recurrences exist in cases where the complete tumor removal was not possible. In such cases (fractionated) stereotactic radiotherapy (SRT) can offer an alternative treatment option. We evaluated the local control rate, symptomatology, and toxicity. Patients and Methods: Between 1997 and 2003, 183 patients with skull-base meningiomas were treated with SRT, among them were 65 patients with meningiomas that compressed optical pathways (64 benign, 1 atypical). Of these 65 cases, 20 were treated with SRT only, 27 were subtotally resected before SRT, and 18 underwent multiple tumor resections before SRT. We investigated the results until 2005, with a median follow-up of 45 months (range, 22-83 months). The tumor volume (TV = gross tumor volume) ranged from 0.61 to 90.20 cc (mean, 18.9 cc). Because of the risk of new visual disturbances, the dose per fraction was either 2 or 1.8 Gy for all patients, to a total dose of 50 to 60 Gy. Results: The overall survival and the progression-free survival rates for 5 years were assessed to 100% in this patient group. To date, no progression for these meningiomas have been observed. Quantitatively, tumor shrinkage of more than 20%, or more than 2 mm in diameter, was proved in 35 of the 65 cases after SRT. In 29 of the 65 patients, at least 1 of the symptoms improved. On application of the Common Toxicity Criteria (CTC), acute toxicity (Grade 3) was seen in 1 case (worsening of conjunctivitis). Another 2 patients developed late toxicity by LENT-SOMA score, 1 x Grade 1 and 1 x Grade 3 (field of vision loss). Conclusion: As a low-risk and effective treatment option for tumor control, SRT with 1.8 to 2.0 Gy per fraction can also be recommended in case of meningiomas that compress optical pathways. An

  13. SU-F-T-650: The Comparison of Robotic Partial Breast Stereotactic Irradiation Using MLC Vs. Iris Cone

    Energy Technology Data Exchange (ETDEWEB)

    Ding, C; Timmerman, R; Jiang, S; Rahimi, A [UT Southwestern Medical Center, Dallas, TX (United States)

    2016-06-15

    Purpose: To evaluate the dosimetric impact on treatment planning for partial breast stereotactic irradiation using Cyberknife with MLC versus Iris Cone. Methods: Ten patients whom underwent lumpectomy for DCIS or stage I invasive non-lobular epithelial breast cancer were included in this study. All patients were previously treated on the Cyberknife using Iris cone with the prescription dose of 37.5Gy in 5 fractions covering at least 95% of PTV on our phase I SBRT 5 fraction partial breast irradiation trial. Retrospectively, treatment planning was performed and compared using the new Cyberknife M6 MLC system for each patient. Using the same contours and critical organ constraints for both MLC and Iris cone plans, the dose on target and critical organs were analyzed accordingly. Results: Dose to critical organs such as ipsilateral lung, contralateral lung, heart, skin, ipsilateral breast, and rib were analyzed, as well as conformity index and high dose spillage of the target area. In 9 of 10 patients, the MLC plans had less total ipsilateral breast volume encompassing the 50% prescription isodose (mean:22.3±8.2% MLC vs. 31.6±8.0 Iris, p=0.00014) .The MLC plans mean estimated treatment delivery time was significantly less than the Iris plans (51±3.9min vs. 56.2±9min, p=0.03) Both MLC and Iris cone plans were able to meet all dose constraints and there was no statistical difference between those dose constraints. Conclusion: Both MLC and Iris Cone can deliver conformal dose to a partial breast target and satisfy the dose constraints of critical organs. The new Cyberknife with MLC can deliver a more conformal dose in the lower dose region and spare more ipsilateral breast tissue to the 50% prescription isodose. The treatment time for partial breast SBRT plans was also reduced using MLC. Project receives research support from Accuray Inc.

  14. A new treatment method for brain diseases. Stereotactic radiosurgery

    International Nuclear Information System (INIS)

    Shirato, Hiroki

    1994-01-01

    This paper deals with stereotactic radiosurgery, a novel medical treatment technique for brain diseases. It is the most sophisticated modality that allows the functional preservation. Recently, CT scan and MRI scan have dramatically changed the diagnostic accuracy of tumor localization in the brain. A device named stereotactic head fixation system makes it possible to localize deep-seated brain diseases with an accuracy of 1-1.5 mm. Using multiple convergent narrow beams of high-energy X-ray, a stereotactic head frame, and a three dimensional computer graphics of CT images, patients with deep-seated nidus can be treated without any complications. Normal tissues would not receive large doses but the center of the nidus is irradiated heavily because of the convergence of X-ray beams. Thus stereotactic radiosurgery is more accurate, effective, and less toxic than conventional radiotherapy and is safer and more effective than surgery for many brain diseases. Small arteriovenous malformation in the brain, which is a fetal disease, and small acoustic neurinomas, in which surgery often causes facial nerve palsy and hearing loss, are presented as good candidates for radiosurgery. For metastatic brain tumors, stereotactic radiosurgery makes such patients free from neurological symptoms, such as difficulty in walking and speaking, in a few days. (N.K.)

  15. The situation of radiotherapy in 2011

    International Nuclear Information System (INIS)

    2012-06-01

    Published within the frame of the French 2009-2013 cancer plan, this report proposes an analysis of the situation of radiotherapy in France. More particularly, it analyses the French offer in terms of radiotherapy treatments and the French position in Europe. A second part analyses equipment (accelerators and other equipment) and techniques aimed at radiotherapy treatment preparation and delivery. The following techniques are addressed: three-dimensional conformational, intensity modulation, intracranial and extracranial stereotactic, image-guided, total body irradiation, hadron-therapy, and peri-operative radiotherapy. The last parts analyse the activity of radiotherapy centres in terms of treated patients, of patient age structure, of sessions and preparations, and of treated pathologies, the medical and paramedical personnel in charge of radiotherapy, and financial and cost aspects

  16. Extracranial radiotherapy in stereotaxic conditions

    International Nuclear Information System (INIS)

    Noel, Georges; Moty-Monnereau, Celine; Meyer, Aurelia; David, Pauline; Pages, Frederique; Muller, Felix; Lee-Robin, Sun Hae; David, Denis Jean

    2006-12-01

    This document reports a literature survey and the discussion of an expert group with the objective to assess the use of extracranial radiotherapy devices in stereotaxic conditions. After a brief overview of the technological context, the authors proposes a technical description of radiotherapy in stereotaxic conditions, of the CyberKnife, of others radiotherapy techniques in stereotaxic conditions for extracranial indications, and of alternate techniques. They give an overview of concerned pathologies: skeleton, hepatic, bronchopulmonary, pancreas, prostate, kidney, and paediatric tumours. They describe the present care condition in France in terms of classification of medial acts, and of patient homogeneous groups. They provide the identification of this practice in foreign nomenclature. In the next part, they report the assessment, first through a critical analysis of published data and information in terms of act feasibility, efficiency and safety, of act role in the therapeutic strategy, of conditions of execution, and of impact on public health, and secondly through a statement of opinion of the working group in terms of terminology, indications, safety, and conditions of execution

  17. Radiotherapy; Strahlentherapie

    Energy Technology Data Exchange (ETDEWEB)

    Wannenmacher, M. [Heidelberg Univ., Mannheim (Germany). Abt. fuer Klinische Radiologie; Debus, J. [Univ. Heidelberg (Germany). Abt. Radioonkologie und Strahlentherapie; Wenz, F. (eds.) [Universitaetsklinikum Mannheim (Germany). Klinik fuer Strahlentherapie und Radioonkologie

    2006-07-01

    The book is focussed on the actual knowledge on the clinical radiotherapy and radio-oncology. Besides fundamental and general contributions specific organ systems are treated in detail. The book contains the following contributions: Basic principles, radiobiological fundamentals, physical background, radiation pathology, basics and technique of brachytherapy, methodology and technique of the stereotactic radiosurgery, whole-body irradiation, operative radiotherapy, hadron therapy, hpyerthermia, combined radio-chemo-therapy, biometric clinical studies, intensity modulated radiotherapy, side effects, oncological diagnostics; central nervous system and sense organs, head-neck carcinomas, breast cancer, thorax organs, esophagus carcinoma, stomach carcinoma, pancreas carcinoma, heptabiliary cancer and liver metastases, rectal carcinomas, kidney and urinary tract, prostate carcinoma, testicular carcinoma, female pelvis, lymphatic system carcinomas, soft tissue carcinoma, skin cancer, bone metastases, pediatric tumors, nonmalignant diseases, emergency in radio-oncology, supporting therapy, palliative therapy.

  18. Digital linear accelerator: The advantages for radiotherapy

    International Nuclear Information System (INIS)

    Andric, S.; Maksimovic, M.; Dekic, M.; Clark, T.

    1998-01-01

    Technical performances of Digital Linear Accelerator were presented to point out its advantages for clinical radiotherapy treatment. The accelerator installation is earned out at Military Medical Academy, Radiotherapy Department, by Medes and Elekta companies. The unit offers many technical advantages with possibility of introduction new conformal treatment techniques as stereotactic radiosurgery, total body and total skin irradiation. In the paper are underlined advantages in relation to running conventional accelerator units at Yugoslav radiotherapy departments, both from technical and medical point of view. (author)

  19. Impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans

    International Nuclear Information System (INIS)

    Kubo, H. Dale; Wilder, Richard B.; Pappas, Conrad T.E.

    1999-01-01

    Purpose: The authors undertook a study to analyze the impact of collimator leaf width on stereotactic radiosurgery and 3D conformal radiotherapy treatment plans. Methods and Materials: Twelve cases involving primary brain tumors, metastases, or arteriovenous malformations that had been planned with BrainLAB's conventional circular collimator-based radiosurgery system were re-planned using a β-version of BrainLAB's treatment planning software that is compatible with MRC Systems' and BrainLAB's micro-multileaf collimators. These collimators have a minimum leaf width of 1.7 mm and 3.0 mm, respectively, at isocenter. The clinical target volumes ranged from 2.7-26.1 cc and the number of static fields ranged from 3-5. In addition, for 4 prostate cancer cases, 2 separate clinical target volumes were planned using MRC Systems' and BrainLAB's micro-multileaf collimators and Varian's multileaf collimator: the smaller clinical target volume consisted of the prostate gland and the larger clinical target volume consisted of the prostate and seminal vesicles. For the prostate cancer cases, treatment plans were generated using either 6 or 7 static fields. A 'PITV ratio', which the Radiation Therapy Oncology Group defines as the volume encompassed by the prescription isodose surface divided by the clinical target volume, was used as a measure of the quality of treatment plans (a PITV ratio of 1.0-2.0 is desirable). Bladder and rectal volumes encompassed by the prescription isodose surface, isodose distributions and dose volume histograms were also analyzed for the prostate cancer patients. Results: In 75% of the cases treated with radiosurgery, a PITV ratio between 1.0-2.0 could be achieved using a micro-multileaf collimator with a leaf width of 1.7-3.0 mm at isocenter and 3-5 static fields. When the clinical target volume consisted of the prostate gland, the micro-multileaf collimator with a minimum leaf width of 3.0 mm allowed one to decrease the median volume of bladder and

  20. Characteristics of Philips SL-20 linear accelerator used for stereotactic radiosurgery/radiotherapy

    International Nuclear Information System (INIS)

    D'Souza, Harold; Ganesh, T.; Joshi, R.C.; Julka, P.K.; Rath, G.K.; Chander, Subhash; Pant, G.S.

    2002-01-01

    Commissioning of a stereotactic radiosurgery/stereotactic radiotherapy (SRS/SRT) facility on a modified linear accelerator requires validation of mechanical parameters and establishment of parameters, such as tissue maximum ratio (TMR), relative output factors (OF), and off axis ratios (OAR). The mechanical and beam characteristics of Philips SL-20 linear accelerator modified for SRS/SRT were evaluated and presented. The SRS/SRT procedure carried on Philips SL-20 linear accelerator with Brown-Robert-Wells (BRW) and relocatable Gill-Thomas-Cosman (GTC) head frames along with the Radionics planning system was evaluated. The tertiary collimator consists of the actual treatment cones and their sizes vary from 12.5 mm to 40 mm diameter. The alignment of the auxillary collimator axis with mechanical axes and stability of the isocenter of Philips SL-20 machine was evaluated using Iso-Align device and mechanical isocenter standard (MIS). All the mechanical errors of the linear accelerator were within 1 mm, except the stability of the isocenter while rotating the couch. Alignment of auxiliary collimator axis with the central axis, gantry and couch axes were achieved. The TMR, OF and OAR for 6 MV x-rays from Philips SL-20 linear accelerator for different cone sizes were deduced using a Multidata water phantom with 0.015 cc ion chamber. The difference between 50% width of profiles in two major axes (x and y) were within ± 0.4 mm. The cone dimensions were accurate up to 0.7 mm. The penumbra width for different cones varies from 3.1 mm to 3.5 mm. Dose linearity of the monitoring system was ≤ 1% above 5 MU. The mechanical and beam characteristics including dose linearity of the SL-20 machine are presented. The beam characteristics of this machine are comparable with the other modified linear accelerators for SRS/SRT. The shift of isocenter during rotation of couch can be nullified by fine adjusting laser target localizing frame to the laser position using micrometer screws

  1. Interpreting survival data from clinical trials of surgery versus stereotactic body radiation therapy in operable Stage I non-small cell lung cancer patients.

    Science.gov (United States)

    Samson, Pamela; Keogan, Kathleen; Crabtree, Traves; Colditz, Graham; Broderick, Stephen; Puri, Varun; Meyers, Bryan

    2017-01-01

    To identify the variability of short- and long-term survival outcomes among closed Phase III randomized controlled trials with small sample sizes comparing SBRT (stereotactic body radiation therapy) and surgical resection in operable clinical Stage I non-small cell lung cancer (NSCLC) patients. Clinical Stage I NSCLC patients who underwent surgery at our institution meeting the inclusion/exclusion criteria for STARS (Randomized Study to Compare CyberKnife to Surgical Resection in Stage I Non-small Cell Lung Cancer), ROSEL (Trial of Either Surgery or Stereotactic Radiotherapy for Early Stage (IA) Lung Cancer), or both were identified. Bootstrapping analysis provided 10,000 iterations to depict 30-day mortality and three-year overall survival (OS) in cohorts of 16 patients (to simulate the STARS surgical arm), 27 patients (to simulate the pooled surgical arms of STARS and ROSEL), and 515 (to simulate the goal accrual for the surgical arm of STARS). From 2000 to 2012, 749/873 (86%) of clinical Stage I NSCLC patients who underwent resection were eligible for STARS only, ROSEL only, or both studies. When patients eligible for STARS only were repeatedly sampled with a cohort size of 16, the 3-year OS rates ranged from 27 to 100%, and 30-day mortality varied from 0 to 25%. When patients eligible for ROSEL or for both STARS and ROSEL underwent bootstrapping with n=27, the 3-year OS ranged from 46 to 100%, while 30-day mortality varied from 0 to 15%. Finally, when patients eligible for STARS were repeatedly sampled in groups of 515, 3-year OS narrowed to 70-85%, with 30-day mortality varying from 0 to 4%. Short- and long-term survival outcomes from trials with small sample sizes are extremely variable and unreliable for extrapolation. Copyright © 2016 Elsevier Ireland Ltd. All rights reserved.

  2. Preliminary shielding calculation for the system of CyberKnife robotic radiosurgery

    International Nuclear Information System (INIS)

    Toreti, Dalila; Xavier, Clarice; Moura, Fabio

    2011-01-01

    The CyberKnife robotic system uses a manipulator with six grade of freedom for positioning a 6 MV Linac accelerator for treatment of lesions. This paper presents calculations for a standard room, with 200 cm of thickness walls primary, build for a CyberKnife system, and calculations for a room originally designed for a Linac conventional (with gantry), with secondary barriers of 107 cm thickness. After the realization of shielding for both rooms, the results shown that walls of standard room with 200 cm thickness are adequate for the secondary shield, and for a room with a conventional Linac, from all six evaluated points, two would require additional shielding of nine cm and four cm of concrete with 2.4 g/cubic cm. This shows that the CyberKnife system can be installed in a originally designed room for a conventional Linac with neither restrict nor any shielding, since no incidence of beams on the secondary barriers is existent

  3. Dose–response of critical structures in the posterior eye segment to hypofractioned stereotactic photon radiotherapy of choroidal melanoma

    International Nuclear Information System (INIS)

    Dunavoelgyi, Roman; Georg, Dietmar; Zehetmayer, Martin; Schmidt-Erfurth, Ursula; Pötter, Richard; Dörr, Wolfgang; Dieckmann, Karin

    2013-01-01

    Purpose: To identify modifying factors and dose–/volume–response relationships for the retina and optic nerve related to highly conformal hypofractionated radiotherapy. Patients and methods: Seventy-three patients undergoing hypofractionated stereotactic photon radiotherapy of choroidal melanoma were included in this retrospective study. The volumes of the optic nerve receiving doses of more than 7.5 or 12 Gy, respectively, were defined. Optic nerve circumference included in the 30%, 40%, 50%, or 80% isodose (ON % ) and retina included in 30% or 40% were determined as quantal effects. Univariate and multivariate analyses were performed for clinical variables as well as probit analysis to define EDx (doses where a positive response is expected in x% of the cases). Results: Median follow-up was 90.0 (interquartile range 69.0–98.0) months. Fifty-two (71%) and 49 (67%) patients developed radiation retinopathy and optic neuropathy (any grade). Age, length of follow-up and diabetes were significant parameters regarding retinopathy. Optic neuropathy was significantly influenced by age, length of follow-up, and ON 30 . The probability of optic neuropathy (any grade and grade ⩾2) significantly increases with the dose (p ranges from 0.0126 to 0.0211). Conclusion: Treatment planning should aim at minimizing encompassing isodoses particularly in the low dose region, without compromising PTV coverage

  4. The Early Result of Whole Pelvic Radiotherapy and Stereotactic Body Radiotherapy Boost for High Risk Localized Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Yu-Wei eLin

    2014-10-01

    Full Text Available PurposeThe rationale for hypofractionated radiotherapy in the treatment of prostate cancer is based on the modern understanding of radiobiology and advances in stereotactic body radiotherapy (SBRT techniques. Whole-pelvis irradiation combined with SBRT boost for high-risk prostate cancer might escalate biologically effective dose without increasing toxicity. Here, we report our 4-year results of SBRT boost for high-risk localized prostate cancer.Methods and MaterialsFrom October 2009 to August 2012, 41 patients of newly diagnosed, high-risk or very high-risk (NCCN definition localized prostate cancer patients were treated with whole-pelvis irradiation and SBRT boost. The whole pelvis dose was 45Gy (25 fractions of 1.8Gy. The SBRT boost dose was 21 Gy (three fractions of 7 Gy. Ninety percent of these patients received hormone therapy. The toxicities of gastrointestinal (GI and genitourinary (GU tracts were scored by Common Toxicity Criteria Adverse Effect (CTCAE v3.0. Biochemical failure was defined by Phoenix definition.ResultsMedian follow-up was 42 months. Mean PSA before treatment was 44.18 ng/ml. Mean PSA level at 3, 6, 12, 18, and 24 months was 0.94, 0.44, 0.13, 0.12, and 0.05 ng/ml, respectively. The estimated 4-year biochemical failure-free survival was 91.9%. Three biochemical failures were observed. GI and GU tract toxicities were minimal. No grade 3 acute GU or GI toxicity was noted. During radiation therapy, 27% of the patient had grade 2 acute GU toxicity and 12% had grade 2 acute GI toxicity. At 3 months, most toxicity scores had returned to baseline. At the last follow up, there was no grade 3 late GU or GI toxicity.ConclusionsWhole-pelvis irradiation combined with SBRT boost for high-risk localized prostate cancer is feasible with minimal toxicity and encouraging biochemical failure-free survival. Continued accrual and follow-up would be necessary to confirm the biochemical control rate and the toxicity profiles.

  5. SU-E-QI-21: Iodinated Contrast Agent Time Course In Human Brain Metastasis: A Study For Stereotactic Synchrotron Radiotherapy Clinical Trials

    Energy Technology Data Exchange (ETDEWEB)

    Obeid, L; Esteve, F; Adam, J [Grenoble Institut des Neurosciences, La Tronche, Isere (France); Tessier, A; Balosso, J [Centre Hospitalier Universitaire, La Tronche, Isere (France)

    2014-06-15

    Purpose: Synchrotron stereotactic radiotherapy (SSRT) is an innovative treatment combining the selective accumulation of heavy elements in tumors with stereotactic irradiations using monochromatic medium energy x-rays from a synchrotron source. Phase I/II clinical trials on brain metastasis are underway using venous infusion of iodinated contrast agents. The radiation dose enhancement depends on the amount of iodine in the tumor and its time course. In the present study, the reproducibility of iodine concentrations between the CT planning scan day (Day 0) and the treatment day (Day 10) was assessed in order to predict dose errors. Methods: For each of days 0 and 10, three patients received a biphasic intravenous injection of iodinated contrast agent (40 ml, 4 ml/s, followed by 160 ml, 0.5 ml/s) in order to ensure stable intra-tumoral amounts of iodine during the treatment. Two volumetric CT scans (before and after iodine injection) and a multi-slice dynamic CT of the brain were performed using conventional radiotherapy CT (Day 0) or quantitative synchrotron radiation CT (Day 10). A 3D rigid registration was processed between images. The absolute and relative differences of absolute iodine concentrations and their corresponding dose errors were evaluated in the GTV and PTV used for treatment planning. Results: The differences in iodine concentrations remained within the standard deviation limits. The 3D absolute differences followed a normal distribution centered at zero mg/ml with a variance (∼1 mg/ml) which is related to the image noise. Conclusion: The results suggest that dose errors depend only on the image noise. This study shows that stable amounts of iodine are achievable in brain metastasis for SSRT treatment in a 10 days interval.

  6. Stereotactic radiosurgery vs. fractionated radiotherapy for tumor control in vestibular schwannoma patients: a systematic review.

    Science.gov (United States)

    Persson, Oscar; Bartek, Jiri; Shalom, Netanel Ben; Wangerid, Theresa; Jakola, Asgeir Store; Förander, Petter

    2017-06-01

    Repeated controlled studies have revealed that stereotactic radiosurgery is better than microsurgery for patients with vestibular schwannoma (VS) 18 years) patients with unilateral VS, followed for a median of >5 years, were eligible for inclusion. After screening titles and abstracts of the 1094 identified articles and systematically reviewing 98 of these articles, 19 were included. Patients with unilateral VS treated with radiosurgery were compared to patients treated with fractionated stereotactic radiotherapy. No randomized controlled trial (RCT) was identified. None of the identified controlled studies comparing SRS with FSRT were eligible according to the inclusion criteria. Nineteen case series on SRS (n = 17) and FSRT (n = 2) were included in the systematic review. Loss of tumor control necessitating a new VS-targeted intervention was found in an average of 5.0% of the patients treated with SRS and in 4.8% treated with FSRT. Mean deterioration ratio for patients with serviceable hearing before treatment was 49% for SRS and 45% for FSRT, respectively. The risk for facial nerve deterioration was 3.6% for SRS and 11.2% for FSRT and for trigeminal nerve deterioration 6.0% for SRS and 8.4% for FSRT. Since these results were obtained from case series, a regular meta-analysis was not attempted. SRS and FSRT are both noninvasive treatment alternatives for patients with VS with low rates of treatment failure in need of rescue therapy. In this selection of patients, the progression-free survival rates were on the order of 92-100% for both treatment options. There is a lack of high-quality studies comparing radiation therapy alternatives for patients with VS. Finally, 19 articles reported long-term tumor control after SRS, while only 2 articles reported long-term FSRT results, making effect estimates more uncertain for FSRT.

  7. Single Fraction Versus Fractionated Linac-Based Stereotactic Radiotherapy for Vestibular Schwannoma: A Single-Institution Experience

    Energy Technology Data Exchange (ETDEWEB)

    Collen, Christine, E-mail: ccollen@uzbrussel.be [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Ampe, Ben [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Gevaert, Thierry [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Moens, Maarten [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Linthout, Nadine; De Ridder, Mark; Verellen, Dirk [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); D' Haens, Jean [Department of Neurosurgery, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium); Storme, Guy [Department of Radiation Oncology, UZ Brussel, Vrije Universiteit Brussel (VUB), Laarbeeklaan 101, 1090 Brussels (Belgium)

    2011-11-15

    Purpose: To evaluate and compare outcomes for patients with vestibular schwannoma (VS) treated in a single institution with linac-based stereotactic radiosurgery (SRS) or by fractionated stereotactic radiotherapy (SRT). Methods and Materials: One hundred and nineteen patients (SRS = 78, SRT = 41) were treated. For both SRS and SRT, beam shaping is performed by a mini-multileaf collimator. For SRS, a median single dose of 12.5 Gy (range, 11-14 Gy), prescribed to the 80% isodose line encompassing the target, was applied. Of the 42 SRT treatments, 32 treatments consisted of 10 fractions of 3-4 Gy, and 10 patients received 25 sessions of 2 Gy, prescribed to the 100% with the 95% isodose line encompassing the planning target volume. Mean largest tumor diameter was 16.6 mm in the SRS and 24.6 mm in the SRT group. Local tumor control, cranial nerve toxicity, and preservation of useful hearing were recorded. Any new treatment-induced cranial nerve neuropathy was scored as a complication. Results: Median follow-up was 62 months (range, 6-136 months), 5 patients progressed, resulting in an overall 5-year local tumor control of 95%. The overall 5-year facial nerve preservation probability was 88% and facial nerve neuropathy was statistically significantly higher after SRS, after prior surgery, for larger tumors, and in Koos Grade {>=}3. The overall 5-year trigeminal nerve preservation probability was 96%, not significantly influenced by any of the risk factors. The overall 4-year probability of preservation of useful hearing (Gardner-Robertson score 1 or 2) was 68%, not significantly different between SRS or SRT (59% vs. 82%, p = 0.089, log rank). Conclusion: Linac-based RT results in good local control and acceptable clinical outcome in small to medium-sized vestibular schwannomas (VSs). Radiosurgery for large VSs (Koos Grade {>=}3) remains a challenge because of increased facial nerve neuropathy.

  8. Hypofractionated Stereotactic Radiosurgery in a Large Bilateral Thalamic and Basal Ganglia Arteriovenous Malformation

    Directory of Open Access Journals (Sweden)

    Janet Lee

    2013-01-01

    Full Text Available Purpose. Arteriovenous malformations (AVMs in the basal ganglia and thalamus have a more aggressive natural history with a higher morbidity and mortality than AVMs in other locations. Optimal treatment—complete obliteration without new neurological deficits—is often challenging. We present a patient with a large bilateral basal ganglia and thalamic AVM successfully treated with hypofractionated stereotactic radiosurgery (HFSRS with intensity modulated radiotherapy (IMRT. Methods. The patient was treated with hypofractionated stereotactic radiosurgery to 30 Gy at margin in 5 fractions of 9 static fields with a minimultileaf collimator and intensity modulated radiotherapy. Results. At 10 months following treatment, digital subtraction angiography showed complete obliteration of the AVM. Conclusions. Large bilateral thalamic and basal ganglia AVMs can be successfully treated with complete obliteration by HFSRS with IMRT with relatively limited toxicity. Appropriate caution is recommended.

  9. A phase-I trial of pre‐operative, margin intensive, stereotactic body radiation therapy for pancreatic cancer: the ‘SPARC’ trial protocol

    International Nuclear Information System (INIS)

    Holyoake, Daniel L. P.; Ward, Elizabeth; Grose, Derek; McIntosh, David; Sebag-Montefiore, David; Radhakrishna, Ganesh; Patel, Neel; Silva, Michael; Mukherjee, Somnath; Strauss, Victoria Y.; Odondi, Lang’o; Fokas, Emmanouil; Melcher, Alan; Hawkins, Maria A.

    2016-01-01

    Standard therapy for borderline-resectable pancreatic cancer in the UK is surgery with adjuvant chemotherapy, but rates of resection with clear margins are unsatisfactory and overall survival remains poor. Meta-analysis of single-arm studies shows the potential of neo-adjuvant chemo-radiotherapy but the relative radio-resistance of pancreatic cancer means the efficacy of conventional dose schedules is limited. Stereotactic radiotherapy achieves sufficient accuracy and precision to enable pre-operative margin-intensive dose escalation with the goal of increasing rates of clear resection margins and local disease control. SPARC is a “rolling-six” design single-arm study to establish the maximum tolerated dose for margin-intensive stereotactic radiotherapy before resection of pancreatic cancer at high risk of positive resection margins. Eligible patients will have histologically or cytologically proven pancreatic cancer defined as borderline-resectable per National Comprehensive Cancer Network criteria or operable tumour in contact with vessels increasing the risk of positive margin. Up to 24 patients will be recruited from up to 5 treating centres and a ‘rolling-six’ design is utilised to minimise delays and facilitate ongoing recruitment during dose-escalation. Radiotherapy will be delivered in 5 daily fractions and surgery, if appropriate, will take place 5–6 weeks after radiotherapy. The margin-intense radiotherapy concept includes a systematic method to define the target volume for a simultaneous integrated boost in the region of tumour-vessel infiltration, and up to 4 radiotherapy dose levels will be investigated. Maximum tolerated dose is defined as the highest dose at which no more than 1 of 6 patients or 0 of 3 patients experience a dose limiting toxicity. Secondary endpoints include resection rate, resection margin status, response rate, overall survival and progression free survival at 12 and 24 months. Translational work will involve exploratory

  10. A new stereotactic apparatus guided by computed tomography

    International Nuclear Information System (INIS)

    Huk, W.J.

    1981-01-01

    The accurate information provided by computer tomography about existence, shape, and localization of intracranial neoplasms in an early phase and in inaccessible regions have improved the diagnostics greatly, so that these lie far ahead of the therapeutic possibilities for brain tumors. To reduce this wide margin we have developed a new targeting device which makes a stereotactic approach to central lesions under sight-control by computed tomography within the computed tomography-scanner possible. With the help of this simple device we are now able to perform stereotactic procedures for tumor biopsy guided by computed tomography, needling and drainage of abscesses and cysts, and finally for the implantation of radioactive material for the interstitial radiotherapy of inoperable cysts and tumors. (orig.) [de

  11. Immune Responses following Stereotactic Body Radiotherapy for Stage I Primary Lung Cancer

    Directory of Open Access Journals (Sweden)

    Yoshiyasu Maehata

    2013-01-01

    Full Text Available Purpose. Immune responses following stereotactic body radiotherapy (SBRT for stage I non-small cell lung cancer (NSCLC were examined from the point of view of lymphocyte subset counts and natural killer cell activity (NKA. Patients and Methods. Peripheral blood samples were collected from 62 patients at 4 time points between pretreatment and 4 weeks post-treatment for analysis of the change of total lymphocyte counts (TLC and lymphocyte subset counts of CD3+, CD4+, CD8+, CD19+, CD56+, and NKA. In addition, the changes of lymphocyte subset counts were compared between patients with or without relapse. Further, the correlations between SBRT-related parameters and immune response were analyzed for the purpose of revealing the mechanisms of the immune response. Results. All lymphocyte subset counts and NKA at post-treatment and 1 week post-treatment were significantly lower than pre-treatment (P<0.01. No significant differences in the changes of lymphocyte subset counts were observed among patients with or without relapse. The volume of the vertebral body receiving radiation doses of 3 Gy or more (VV3 significantly correlated with the changes of nearly all lymphocyte subset counts. Conclusions. SBRT for stage I NSCLC induced significant immune suppression, and the decrease of lymphocyte subset counts may be associated with exposure of the vertebral bone marrow.

  12. Dosimetric benefit of adaptive re-planning in pancreatic cancer stereotactic body radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Li, Yongbao [Department of Engineering Physics, Tsinghua University, Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing (China); Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Hoisak, Jeremy D.P.; Li, Nan; Jiang, Carrie [Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of California San Diego, La Jolla, CA (United States); Tian, Zhen [Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX (United States); Gautier, Quentin; Zarepisheh, Masoud [Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of California San Diego, La Jolla, CA (United States); Wu, Zhaoxia; Liu, Yaqiang [Department of Engineering Physics, Tsinghua University, Key Laboratory of Particle & Radiation Imaging (Tsinghua University), Ministry of Education, Beijing (China); Jia, Xun [Center for Advanced Radiotherapy Technologies University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of California San Diego, La Jolla, CA (United States); Department of Radiation Oncology, University of Texas Southwestern Medical Center, Dallas, TX (United States); and others

    2015-01-01

    Stereotactic body radiotherapy (SBRT) shows promise in unresectable pancreatic cancer, though this treatment modality has high rates of normal tissue toxicity. This study explores the dosimetric utility of daily adaptive re-planning with pancreas SBRT. We used a previously developed supercomputing online re-planning environment (SCORE) to re-plan 10 patients with pancreas SBRT. Tumor and normal tissue contours were deformed from treatment planning computed tomographies (CTs) and transferred to daily cone-beam CT (CBCT) scans before re-optimizing each daily treatment plan. We compared the intended radiation dose, the actual radiation dose, and the optimized radiation dose for the pancreas tumor planning target volume (PTV) and the duodenum. Treatment re-optimization improved coverage of the PTV and reduced dose to the duodenum. Within the PTV, the actual hot spot (volume receiving 110% of the prescription dose) decreased from 4.5% to 0.5% after daily adaptive re-planning. Within the duodenum, the volume receiving the prescription dose decreased from 0.9% to 0.3% after re-planning. It is noteworthy that variation in the amount of air within a patient's stomach substantially changed dose to the PTV. Adaptive re-planning with pancreas SBRT has the ability to improve dose to the tumor and decrease dose to the nearby duodenum, thereby reducing the risk of toxicity.

  13. Stereotactic body radiotherapy for centrally located stage I NSCLC. A multicenter analysis

    Energy Technology Data Exchange (ETDEWEB)

    Schanne, Daniel H.; Nestle, Ursula; Grosu, Anca L. [Universitaetsklinik Freiburg, Klinik fuer Strahlenheilkunde, Freiburg (Germany); Allgaeuer, Michael [Barmherzige Brueder, Klinik fuer Strahlentherapie, Regensburg (Germany); Andratschke, Nicolaus; Molls, Michael [TU Muenchen, Klinik und Poliklinik fuer Strahlentherapie und Radiologische Onkologie, Muenchen (Germany); Appold, Steffen [Universitaetsklinikum Dresden, Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie, Dresden (Germany); Dieckmann, Ute [Allgemeines Krankenhaus Wien, Univ. Klinik fuer Strahlentherapie, Wien (Austria); Ernst, Iris [Universitaetsklinikum Muenster, Klinik fuer Strahlentherapie, Muenster (Germany); Ganswindt, Ute [LMU Muenchen, Klinik und Poliklinik fuer Strahlentherapie und Radioonkologie, Muenchen (Germany); Holy, Richard [Universitaetsklinikum Aachen, Klinik fuer Strahlentherapie, Aachen (Germany); Nevinny-Stickel, Meinhard [Medizinischen Universitaet Innsbruck, Univ. Klinik fuer Strahlentherapie und Radioonkologie, Innsbruck (Austria); Semrau, Sabine [Universitaetsklinikum Erlangen, Strahlenklinik Erlangen, Erlangen (Germany); Sterzing, Florian [Universitaetsklinikum Heidelberg, Klinik fuer Radioonkologie und Strahlentherapie, Heidelberg (Germany); Wittig, Andrea [Philipps-Universitaet Marburg, Klinik fuer Strahlentherapie und Radioonkologie, Marburg (Germany); Guckenberger, Matthias [Universitaet Wuerzburg, Klinik und Poliklinik fuer Strahlentherapie, Wuerzburg (Germany)

    2014-08-27

    The purpose of this work is to analyze patterns of care and outcome after stereotactic body radiotherapy (SBRT) for centrally located, early-stage, non-small cell lung cancer (NSCLC) and to address the question of potential risk for increased toxicity in this entity. A total of 90 patients with centrally located NSCLC were identified among 613 cases in a database of 13 German and Austrian academic radiotherapy centers. The outcome of centrally located NSCLC was compared to that of cases with peripheral tumor location from the same database. Patients with central tumors most commonly presented with UICC stage IB (50 %), while the majority of peripheral lesions were stage IA (56 %). Average tumor diameters were 3.3 cm (central) and 2.8 cm (peripheral). Staging PET/CT was available for 73 and 74 % of peripheral and central tumors, respectively. Biopsy was performed in 84 % (peripheral) and 88 % (central) of cases. Doses varied significantly between central and peripheral lesions with a median BED{sub 10} of 72 Gy and 84 Gy, respectively (p < 0.001). Fractionation differed as well with medians of 5 (central) and 3 (peripheral) fractions (p < 0.001). In the Kaplan-Meier analysis, 3-year actuarial overall survival was 29 % (central) and 51 % (peripheral; p = 0.004) and freedom from local progression was 52 % (central) and 84 % (peripheral; p < 0.001). Toxicity after treatment of central tumors was low with no grade III/IV and one grade V event. Mortality rates were 0 and 1 % after 30 and 60 days, respectively. Local tumor control in patients treated with SBRT for centrally located, early-stage NSCLC was favorable, provided ablative radiation doses were prescribed. This was, however, not the case in the majority of patients, possibly due to concerns about treatment-related toxicity. Reported toxicity was low, but prospective trials are needed to resolve the existing uncertainties and to establish safe high-dose regimens for this cohort of patients. (orig.) [German] Ziel

  14. Evaluation of a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Imae, Toshikazu; Takenaka, Shigeharu; Saotome, Naoya

    2016-01-01

    The purpose of this study was to evaluate a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT). VMAT is capable of acquiring respiratory signals derived from projection images and machine parameters based on machine logs during VMAT delivery. Dose distributions were reconstructed from the respiratory signals and machine parameters in the condition where respiratory signals were without division, divided into 4 and 10 phases. The dose distribution of each respiratory phase was calculated on the planned four-dimensional CT (4DCT). Summation of the dose distributions was carried out using deformable image registration (DIR), and cumulative dose distributions were compared with those of the corresponding plans. Without division, dose differences between cumulative distribution and plan were not significant. In the condition Where respiratory signals were divided, dose differences were observed over dose in cranial region and under dose in caudal region of planning target volume (PTV). Differences between 4 and 10 phases were not significant. The present method Was feasible for evaluating cumulative dose distribution in VMAT-SBRT using 4DCT and DIR. (author)

  15. SU-E-T-91: Accuracy of Dose Calculation Algorithms for Patients Undergoing Stereotactic Ablative Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Tajaldeen, A [RMIT university, Docklands, Vic (Australia); Ramachandran, P [Peter MacCallum Cancer Centre, Bendigo (Australia); Geso, M [RMIT University, Bundoora, Melbourne (Australia)

    2015-06-15

    Purpose: The purpose of this study was to investigate and quantify the variation in dose distributions in small field lung cancer radiotherapy using seven different dose calculation algorithms. Methods: The study was performed in 21 lung cancer patients who underwent Stereotactic Ablative Body Radiotherapy (SABR). Two different methods (i) Same dose coverage to the target volume (named as same dose method) (ii) Same monitor units in all algorithms (named as same monitor units) were used for studying the performance of seven different dose calculation algorithms in XiO and Eclipse treatment planning systems. The seven dose calculation algorithms include Superposition, Fast superposition, Fast Fourier Transform ( FFT) Convolution, Clarkson, Anisotropic Analytic Algorithm (AAA), Acurous XB and pencil beam (PB) algorithms. Prior to this, a phantom study was performed to assess the accuracy of these algorithms. Superposition algorithm was used as a reference algorithm in this study. The treatment plans were compared using different dosimetric parameters including conformity, heterogeneity and dose fall off index. In addition to this, the dose to critical structures like lungs, heart, oesophagus and spinal cord were also studied. Statistical analysis was performed using Prism software. Results: The mean±stdev with conformity index for Superposition, Fast superposition, Clarkson and FFT convolution algorithms were 1.29±0.13, 1.31±0.16, 2.2±0.7 and 2.17±0.59 respectively whereas for AAA, pencil beam and Acurous XB were 1.4±0.27, 1.66±0.27 and 1.35±0.24 respectively. Conclusion: Our study showed significant variations among the seven different algorithms. Superposition and AcurosXB algorithms showed similar values for most of the dosimetric parameters. Clarkson, FFT convolution and pencil beam algorithms showed large differences as compared to superposition algorithms. Based on our study, we recommend Superposition and AcurosXB algorithms as the first choice of

  16. SU-E-T-91: Accuracy of Dose Calculation Algorithms for Patients Undergoing Stereotactic Ablative Radiotherapy

    International Nuclear Information System (INIS)

    Tajaldeen, A; Ramachandran, P; Geso, M

    2015-01-01

    Purpose: The purpose of this study was to investigate and quantify the variation in dose distributions in small field lung cancer radiotherapy using seven different dose calculation algorithms. Methods: The study was performed in 21 lung cancer patients who underwent Stereotactic Ablative Body Radiotherapy (SABR). Two different methods (i) Same dose coverage to the target volume (named as same dose method) (ii) Same monitor units in all algorithms (named as same monitor units) were used for studying the performance of seven different dose calculation algorithms in XiO and Eclipse treatment planning systems. The seven dose calculation algorithms include Superposition, Fast superposition, Fast Fourier Transform ( FFT) Convolution, Clarkson, Anisotropic Analytic Algorithm (AAA), Acurous XB and pencil beam (PB) algorithms. Prior to this, a phantom study was performed to assess the accuracy of these algorithms. Superposition algorithm was used as a reference algorithm in this study. The treatment plans were compared using different dosimetric parameters including conformity, heterogeneity and dose fall off index. In addition to this, the dose to critical structures like lungs, heart, oesophagus and spinal cord were also studied. Statistical analysis was performed using Prism software. Results: The mean±stdev with conformity index for Superposition, Fast superposition, Clarkson and FFT convolution algorithms were 1.29±0.13, 1.31±0.16, 2.2±0.7 and 2.17±0.59 respectively whereas for AAA, pencil beam and Acurous XB were 1.4±0.27, 1.66±0.27 and 1.35±0.24 respectively. Conclusion: Our study showed significant variations among the seven different algorithms. Superposition and AcurosXB algorithms showed similar values for most of the dosimetric parameters. Clarkson, FFT convolution and pencil beam algorithms showed large differences as compared to superposition algorithms. Based on our study, we recommend Superposition and AcurosXB algorithms as the first choice of

  17. SU-E-T-630: Predictive Modeling of Mortality, Tumor Control, and Normal Tissue Complications After Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer

    International Nuclear Information System (INIS)

    Lindsay, WD; Berlind, CG; Gee, JC; Simone, CB

    2015-01-01

    Purpose: While rates of local control have been well characterized after stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC), less data are available characterizing survival and normal tissue toxicities, and no validated models exist assessing these parameters after SBRT. We evaluate the reliability of various machine learning techniques when applied to radiation oncology datasets to create predictive models of mortality, tumor control, and normal tissue complications. Methods: A dataset of 204 consecutive patients with stage I non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT) at the University of Pennsylvania between 2009 and 2013 was used to create predictive models of tumor control, normal tissue complications, and mortality in this IRB-approved study. Nearly 200 data fields of detailed patient- and tumor-specific information, radiotherapy dosimetric measurements, and clinical outcomes data were collected. Predictive models were created for local tumor control, 1- and 3-year overall survival, and nodal failure using 60% of the data (leaving the remainder as a test set). After applying feature selection and dimensionality reduction, nonlinear support vector classification was applied to the resulting features. Models were evaluated for accuracy and area under ROC curve on the 81-patient test set. Results: Models for common events in the dataset (such as mortality at one year) had the highest predictive power (AUC = .67, p < 0.05). For rare occurrences such as radiation pneumonitis and local failure (each occurring in less than 10% of patients), too few events were present to create reliable models. Conclusion: Although this study demonstrates the validity of predictive analytics using information extracted from patient medical records and can most reliably predict for survival after SBRT, larger sample sizes are needed to develop predictive models for normal tissue toxicities and more advanced

  18. SU-E-T-630: Predictive Modeling of Mortality, Tumor Control, and Normal Tissue Complications After Stereotactic Body Radiotherapy for Stage I Non-Small Cell Lung Cancer

    Energy Technology Data Exchange (ETDEWEB)

    Lindsay, WD [University of Pennsylvania, Philadelphia, PA (United States); Oncora Medical, LLC, Philadelphia, PA (United States); Berlind, CG [Georgia Institute of Technology, Atlanta, GA (Georgia); Oncora Medical, LLC, Philadelphia, PA (United States); Gee, JC; Simone, CB [University of Pennsylvania, Philadelphia, PA (United States)

    2015-06-15

    Purpose: While rates of local control have been well characterized after stereotactic body radiotherapy (SBRT) for stage I non-small cell lung cancer (NSCLC), less data are available characterizing survival and normal tissue toxicities, and no validated models exist assessing these parameters after SBRT. We evaluate the reliability of various machine learning techniques when applied to radiation oncology datasets to create predictive models of mortality, tumor control, and normal tissue complications. Methods: A dataset of 204 consecutive patients with stage I non-small cell lung cancer (NSCLC) treated with stereotactic body radiotherapy (SBRT) at the University of Pennsylvania between 2009 and 2013 was used to create predictive models of tumor control, normal tissue complications, and mortality in this IRB-approved study. Nearly 200 data fields of detailed patient- and tumor-specific information, radiotherapy dosimetric measurements, and clinical outcomes data were collected. Predictive models were created for local tumor control, 1- and 3-year overall survival, and nodal failure using 60% of the data (leaving the remainder as a test set). After applying feature selection and dimensionality reduction, nonlinear support vector classification was applied to the resulting features. Models were evaluated for accuracy and area under ROC curve on the 81-patient test set. Results: Models for common events in the dataset (such as mortality at one year) had the highest predictive power (AUC = .67, p < 0.05). For rare occurrences such as radiation pneumonitis and local failure (each occurring in less than 10% of patients), too few events were present to create reliable models. Conclusion: Although this study demonstrates the validity of predictive analytics using information extracted from patient medical records and can most reliably predict for survival after SBRT, larger sample sizes are needed to develop predictive models for normal tissue toxicities and more advanced

  19. Planning benchmark study for SBRT of early stage NSCLC. Results of the DEGRO Working Group Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Moustakis, Christos [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Blanck, Oliver [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Saphir Radiosurgery Center, Guestrow and Frankfurt, Frankfurt (Germany); Ebrahimi Tazehmahalleh, Fatemeh [University Muenster, Department of Radiation Oncology, Muenster (Germany); City Hospital Dessau, Dessau (Germany); Chan, Mark ka heng [UKSH Universitaetsklinikum Schleswig Holstein, Department of Radiation Oncology, Kiel (Germany); Ernst, Iris; Haverkamp, Uwe; Eich, Hans Theodor [University Muenster, Department of Radiation Oncology, Muenster (Germany); German CyberKnife Center, Soest (Germany); Krieger, Thomas [University of Wuerzburg, Department of Radiation Oncology, Wuerzburg (Germany); Duma, Marciana-Nona; Oechsner, Markus [Technical University of Munich, Department of Radiation Oncology, Klinikum rechts der Isar, Munich (Germany); Ganswindt, Ute; Heinz, Christian [Ludwig-Maximilians-University, Department of Radiation Oncology, Munich (Germany); Alheit, Horst; Blank, Hilbert [Radiationtherapy Distler, Bautzen (Germany); Nestle, Ursula; Wiehle, Rolf [University Medical Center Freiburg, Department of Radiation Oncology, Freiburg (Germany); Kornhuber, Christine; Ostheimer, Christian [University Halle, Department of Radiation Oncology, Halle (Germany); Petersen, Cordula [University Hospital Hamburg-Eppendorf, Hamburg (Germany); Pollul, Gerhard [University Mainz, Department of Radiation Oncology, Mainz (Germany); Baus, Wolfgang; Altenstein, Georg [University Hospital of Cologne, Cologne (Germany); Beckers, Eric; Jurianz, Katrin [Gamma Knife Center Krefeld, Krefeld (Germany); Sterzing, Florian [University Hospital Heidelberg, Heidelberg (Germany); Kretschmer, Matthias [Radiologische Allianz Hamburg, Hamburg (Germany); Seegenschmiedt, Heinrich; Maass, Torsten [Radiationtherapy and Cyberknife Center Hamburg, Hamburg (Germany); Droege, Stefan [Lung Clinic Hemer, Hemer (Germany); Wolf, Ulrich [University Leipzig, Department of Radiation Oncology, Leipzig (Germany); Schoeffler, Juergen [Radiationtherapy Department Boeblingen, Boeblingen (Germany); Guckenberger, Matthias [University Zurich, Department of Radiation Oncology, Zurich (Switzerland)

    2017-10-15

    The aim was to evaluate stereotactic body radiation therapy (SBRT) treatment planning variability for early stage nonsmall cell lung cancer (NSCLC) with respect to the published guidelines of the Stereotactic Radiotherapy Working Group of the German Society for Radiation Oncology (DEGRO). Planning computed tomography (CT) scan and the structure sets (planning target volume, PTV; organs at risk, OARs) of 3 patients with early stage NSCLC were sent to 22 radiotherapy departments with SBRT experience: each department was asked to prepare a treatment plan according to the DEGRO guidelines. The prescription dose was 3 fractions of 15 Gy to the 65% isodose. In all, 87 plans were generated: 36 used intensity-modulated arc therapy (IMAT), 21 used three-dimensional conformal radiation therapy (3DCRT), 6 used static field intensity-modulated radiation therapy (SF-IMRT), 9 used helical radiotherapy and 15 used robotic radiosurgery. PTV dose coverage and simultaneously kept OARs doses were within the clinical limits published in the DEGRO guidelines. However, mean PTV dose (mean 58.0 Gy, range 52.8-66.4 Gy) and dose conformity indices (mean 0.75, range 0.60-1.00) varied between institutions and techniques (p ≤ 0.02). OARs doses varied substantially between institutions, but appeared to be technique independent (p = 0.21). All studied treatment techniques are well suited for SBRT of early stage NSCLC according to the DEGRO guidelines. Homogenization of SBRT practice in Germany is possible through the guidelines; however, detailed treatment plan characteristics varied between techniques and institutions and further homogenization is warranted in future studies and recommendations. Optimized treatment planning should always follow the ALARA (as low as reasonably achievable) principle. (orig.) [German] Ziel war die Untersuchung der Variabilitaet der Bestrahlungsplanung der stereotaktischen Strahlentherapie (SBRT) fuer das nicht-kleinzellige Bronchialkarzinom (NSCLC) im

  20. Optical Tracking Technology in Stereotactic Radiation Therapy

    International Nuclear Information System (INIS)

    Wagner, Thomas H.; Meeks, Sanford L.; Bova, Frank J.; Friedman, William A.; Willoughby, Twyla R.; Kupelian, Patrick A.; Tome, Wolfgang

    2007-01-01

    The last decade has seen the introduction of advanced technologies that have enabled much more precise application of therapeutic radiation. These relatively new technologies include multileaf collimators, 3-dimensional conformal radiotherapy planning, and intensity modulated radiotherapy in radiotherapy. Therapeutic dose distributions have become more conformal to volumes of disease, sometimes utilizing sharp dose gradients to deliver high doses to target volumes while sparing nearby radiosensitive structures. Thus, accurate patient positioning has become even more important, so that the treatment delivered to the patient matches the virtual treatment plan in the computer treatment planning system. Optical and image-guided radiation therapy systems offer the potential to improve the precision of patient treatment by providing a more robust fiducial system than is typically used in conventional radiotherapy. The ability to accurately position internal targets relative to the linac isocenter and to provide real-time patient tracking theoretically enables significant reductions in the amount of normal tissue irradiated. This report reviews the concepts, technology, and clinical applications of optical tracking systems currently in use for stereotactic radiation therapy. Applications of radiotherapy optical tracking technology to respiratory gating and the monitoring of implanted fiducial markers are also discussed

  1. Effectiveness of fractionated stereotactic radiotherapy for uveal melanoma

    International Nuclear Information System (INIS)

    Muller, Karin; Nowak, Peter; Pan, Connie de; Marijnissen, Johannes P.; Paridaens, Dion A.; Levendag, Peter; Luyten, Gre P.M.

    2005-01-01

    Purpose: To study the effectiveness and acute side effects of fractionated stereotactic radiation therapy (fSRT) for uveal melanoma. Methods and Materials: Between 1999 and 2003, 38 patients (21 male, 17 female) were included in a prospective, nonrandomized clinical trial (mean follow-up of 25 months). A total dose of 50 Gy was given in 5 consecutive days. A blinking light and a camera (to monitor the position of the diseased eye) were fixed to a noninvasive relocatable stereotactic frame. Primary end points were local control, best corrected visual acuity, and toxicity at 3, 6, 12, and 24 months, respectively. Results: After 3 months (38 patients), the local control was 100%; after 12 months (32 patients) and 24 months (15 patients), no recurrences were seen. The best corrected visual acuity declined from a mean of 0.21 at diagnosis to 0.06 2 years after therapy. The acute side effects after 3 months were as follows: conjunctival symptoms (10), loss of lashes or hair (6), visual symptoms (5), fatigue (5), dry eye (1), cataract (1), and pain (4). One eye was enucleated at 2 months after fSRT. Conclusions: Preliminary results demonstrate that fSRT is an effective and safe treatment modality for uveal melanoma with an excellent local control and mild acute side effects. The follow-up should be prolonged to study both long-term local control and late toxicity

  2. Quality assurance for an image-guided frameless radiosurgery system using radiochromic film

    International Nuclear Information System (INIS)

    Shiomi, Hiroya; Inoue, Takehiro; Nakamura, Satoaki; Inoue, Toshihiko

    2000-01-01

    The CyberKnife, a new type of machine for stereotactic irradiation, is composed of a combination of a robot (manipulator) and a linear accelerator. We measured the total pointing error of the therapy beam, aiming at improvement in the accuracy of the CyberKnife. The CyberKnife keeps a number of coordinate systems such as the patient's coordinates, robotic coordinates, and IPS (image processing system) coordinates. Precise irradiation is possible if these coordinate systems are matched accurately. We always calculate the overall irradiation error using GAF MD-55 radiochromic film before irradiation treatment of the patient, and we have attempted to improve the accuracy of irradiation with the CyberKnife by feeding back the errors. The median of the error immediately after introducing the CyberKnife was 1.2 mm, and as a result of correction, we succeeded in reducing the error to 0.7 mm (median). Total pointing error after correction was significantly lower than that before correction (p=0.0023). This approach allowed us to reduce errors and establish a method for providing patients with highly accurate stereotactic irradiation. We believe these results endorse the validity of the method presented in this paper. (author)

  3. Monte Carlo simulations for stereotactic radiotherapy system with various kilo-voltage x-ray energy

    International Nuclear Information System (INIS)

    Deloar, H.M.; Kunieda, E.; Kawase, T.; Kubo, Atsushi; Saitoh, H.; Myojoyama, A.; Ozaki, M.; Fujisaki, T.; Saito, K.

    2005-01-01

    Stereotactic radiotherapy (SRT) of lung tumors with a narrow and precise medium energy x-ray beam where the homogeneous high dose area will be confined within the tumors are desirable. A conventional x-ray CT with medium energy x-ray has been modified to develop a radiotherapy system for lung SRT. A cylindrical collimator (0.3 cm φ) made of tungsten was introduced to collimate the X-ray beam. The system was simulated with BEAMnrc(EGS4) Monte Carlo code and various x-ray energy spectra were generated to investigate the dose distributions with our kilo-voltage SRT system. Experiments were performed to acquire the energy spectra of 100, 120 and 135 kVp (kilo-voltage peak) from CT measurements and those results were compared with the spectra obtained from Monte Carlo simulations. Verifications of percentage of dose depth (PDD) for 120 and 147.5 kVp were investigated in a water phantom with experiments and Monte Carlo simulations. Finally dose distributions of 120, 135, 147.5, 200, 250, 300, 350, 400, 500 kVp spectra were investigated with lung phantom and human lung. The Percentage of Depth Dose (PDD) in the water phantom calculated from the experimental and simulated spectra of 120 and 147.5 kVp show good agreement with each other. The PDD of 147.5 and 120 kVp spectra at 9 cm depth was approximately 10% and 9%, respectively. Dose distributions around the lung tumor in the phantom and human for all x-ray energies were almost uniform but in the case of the human lung absorptions of dose at ribs for the energy lower than 135 kVp was more than 35% and those absorptions for the energy spectra of 147.5 kVp and above was less than 30%. This absorption gradually decreases with increasing x-ray energies. Uniform dose distributions in the lung region of human and thorax phantom demonstrated the possibility of SRT system with medium energy X-ray. A detail performance of this system as a kilo-voltage conformal radiotherapy is under investigations. (author)

  4. Stereotactic radiation therapy: a second gold standard in the treatment of early-stage lung cancer?

    International Nuclear Information System (INIS)

    Santini B, Alejandro; Valdez C, Cristian; Sepulveda A, Veronica; Baeza L, Ricardo; Bustos, Sergio

    2016-01-01

    Lung cancer is still the leading cause of cancer death in the world. Although in Chile this is not the case, the northern regions of the country show higher incidence and mortality rates than the other Chilean regions. In recent years screening guides for lung cancer with low-dose scanner have begun to be established, and most of the medical societies involved in this subject have already settled the selection criteria. At the same time new techniques of treatment for these patients have developed, with highly sophisticated radiotherapy such as SBRT (Stereotactic Body Radiotherapy) and SBART (Stereotactic ablative body radiation therapy) that are revealing extremely encouraging results and augur significant changes in the coming years. In the present review we analyze the current work, their results, and the future of this treatment modality

  5. WE-G-BRD-03: Development of a Real-Time Optical Tracking Goggle System (OTGS) for Intracranial Stereotactic Radiotherapy

    Energy Technology Data Exchange (ETDEWEB)

    Mittauer, K; Yan, G; Lu, B; Barraclough, B; Li, J; Liu, C [University of Florida, Gainesville, FL (United States)

    2014-06-15

    Purpose: Optical tracking systems (OTS) are an acceptable alternative to frame-based stereotactic radiotherapy (SRT). However, current surface-based OTS lack the ability to target exclusively rigid/bony anatomical features. We propose a novel marker-based optical tracking goggle system (OTGS) that provides real-time guidance based on the nose/facial bony anatomy. This ongoing study involves the development and characterization of the OTGS for clinical implementation in intracranial stereotactic radiotherapy. Methods: The OTGS consists of eye goggles, a custom thermoplastic nosepiece, and 6 infrared markers pre-attached to the goggles. A phantom and four healthy volunteers were used to evaluate the calibration/registration accuracy, intrafraction accuracy, interfraction reproducibility, and end-to-end accuracy of the OTGS. The performance of the OTGS was compared with that of the frameless SonArray system and cone-beam computed tomography (CBCT) for volunteer and phantom cases, respectively. The performance of the OTGS with commercial immobilization devices and under treatment conditions (i.e., couch rotation and translation range) was also evaluated. Results: The difference in the calibration/registration accuracy of 24 translations or rotation combinations between CBCT and in-house OTS software was within 0.5 mm/0.4°. The mean intrafraction and interfraction accuracy among the volunteers was 0.004+/−0.4mm with −0.09+/−0.5° (n=6,170) and −0.26+/−0.8mm with 0.15+/0.8° (n=11), respectively. The difference in end-to-end accuracy between the OTGS and CBCT was within 1.3 mm/1.1°. The predetermined marker pattern (1) minimized marker occlusions, (2) allowed for continuous tracking for couch angles +/− 90°, (3) and eliminated individual marker misplacement. The device was feasible with open and half masks for immobilization. Conclusion: Bony anatomical localization eliminated potential errors due to facial hair changes and/or soft tissue deformation. The

  6. Role of Radiotherapy in Metastatic Non-small Cell Lung Cancer (NSCLC

    Directory of Open Access Journals (Sweden)

    Sergio L. Faria

    2014-10-01

    Full Text Available Radiotherapy has had important role in the palliation of NSCLC. Randomized trials tend to suggest that, in general, short regimens give similar palliation and toxicity compared to longer regimens. The benefit of combining chemotherapy to radiosensitize the palliative radiation treatment is an open question, but so far it has not been proved to be very useful in NSCLC. The addition of molecular targeted drugs to radiotherapy outside of approved regimens or clinical trials warrants careful consideration for every single case and probably should not be used as a routine management.Stereotactic radiosurgery (SRS and stereotactic body radiation therapy (SBRT are modern techniques being used each time more frequently in the treatment of single or oligometastases. In general, they offer good tumour control with little toxicity (with a more expensive cost compared to the traditionally fractionated radiotherapy regimens.

  7. Stereotactic radiation therapy for large vestibular schwannomas

    International Nuclear Information System (INIS)

    Mandl, Ellen S.; Meijer, Otto W.M.; Slotman, Ben J.; Vandertop, W. Peter; Peerdeman, Saskia M.

    2010-01-01

    Background and purpose: To evaluate the morbidity and tumor-control rate in the treatment of large vestibular schwannomas (VS) after stereotactic radiation therapy in our institution. Material and methods: Twenty-five consecutive patients (17 men, 8 women) with large VS (diameter 3.0 cm or larger), treated with stereotactic radiotherapy (SRT) or stereotactic radiosurgery (SRS) between 1992 and 2007, were retrospectively studied after a mean follow-up period of three years with respect to tumor-control rate and complications. Results: Actuarial 5-year maintenance of pre-treatment hearing level probability of 30% was achieved. Five of 17 patients suffered permanent new facial nerve dysfunction. The actuarial 5-year facial nerve preservation probability was 80%. Permanent new trigeminal nerve neuropathy occurred in two of 15 patients, resulting in an actuarial 5-year trigeminal nerve preservation probability of 85%. Tumor progression occurred in four of 25 (16%) patients. The overall 5-year tumor control probability was 82%. Conclusion: Increased morbidity rates were found in patients with large VS treated with SRT or SRS compared to the published series on regular sized VS and other smaller retrospective studies on large VS.

  8. Volume Changes After Stereotactic LINAC Radiotherapy in Vestibular Schwannoma: Control Rate and Growth Patterns

    International Nuclear Information System (INIS)

    Langenberg, Rick van de; Dohmen, Amy J.C.; Bondt, Bert J. de; Nelemans, Patty J.; Baumert, Brigitta G.; Stokroos, Robert J.

    2012-01-01

    Purpose: The purpose of this study was to evaluate the control rate of vestibular schwannomas (VS) after treatment with linear accelerator (LINAC)-based stereotactic radiosurgery (SRS) or radiotherapy (SRT) by using a validated volumetric measuring tool. Volume-based studies on prognosis after LINAC-based SRS or SRT for VS are reported scarcely. In addition, growth patterns and risk factors predicting treatment failure were analyzed. Materials and Methods: Retrospectively, 37 VS patients treated with LINAC based SRS or SRT were analyzed. Baseline and follow-up magnetic resonance imaging scans were analyzed with volume measurements on contrast enhanced T1-weighted magnetic resonance imaging. Absence of intervention after radiotherapy was defined as “no additional intervention group, ” absence of radiological growth was defined as “radiological control group. ” Significant growth was defined as a volume change of 19.7% or more, as calculated in a previous study. Results: The cumulative 4-year probability of no additional intervention was 96.4% ± 0.03; the 4-year radiological control probability was 85.4% ± 0.1). The median follow-up was 40 months. Overall, shrinkage was seen in 65%, stable VS in 22%, and growth in 13%. In 54% of all patients, transient swelling was observed. No prognostic factors were found regarding VS growth. Previous treatment and SRS were associated with transient swelling significantly. Conclusions: Good control rates are reported for LINAC based SRS or SRT in VS, in which the lower rate of radiological growth control is attributed to the use of the more sensitive volume measurements. Transient swelling after radiosurgery is a common phenomenon and should not be mistaken for treatment failure. Previous treatment and SRS were significantly associated with transient swelling.

  9. Characteristics of a dedicated linear accelerator-based stereotactic radiosurgery-radiotherapy unit

    International Nuclear Information System (INIS)

    Das, Indra J.; Downes, M. Beverly; Corn, Benjamin W.; Curran, Walter J.; Werner-Wasik, M.; Andrews, David W.

    1996-01-01

    A stereotactic radiosurgery and radiotherapy (SRS/SRT) system on a dedicated Varian Clinac-600SR linear accelerator with Brown-Roberts-Wells and Gill-Thomas-Cosman relocatable frames along with the Radionics (RSA) planning system is evaluated. The Clinac-600SR has a single 6-MV beam with the same beam characteristics as that of the mother unit, the Clinac-600C. The primary collimator is a fixed cone projecting to a 10-cm diameter at isocenter. The secondary collimator is a heavily shielded cylindrical collimator attached to the face plate of the primary collimator. The tertiary collimation consists of the actual treatment cones. The cone sizes vary from 12.5 to 40.0 mm diameter. The mechanical stability of the entire system was verified. The variations in isocenter position with table, gantry, and collimator rotation were found to be <0.5 mm with a compounded accuracy of ≤ 1.0 mm. The radiation leakage under the cones was < 1% measured at a depth of 5 cm in a phantom. The beam profiles of all cones in the x and y directions were within ±0.5 mm and match with the physical size of the cone. The dosimetric data such as tissue maximum ratio, off-axis ratio, and cone factor were taken using film, diamond detector, and ion chambers. The mechanical and dosimetric characteristics including dose linearity of this unit are presented and found to be suitable for SRS/SRT. The difficulty in absolute dose measurement for small cone is discussed

  10. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    Energy Technology Data Exchange (ETDEWEB)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Chapman, Christopher [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of Michigan School of Medicine, Ann Arbor, MI (United States); Rao, Aarti [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Davis, School of Medicine, Davis, CA (United States); Shen, John [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); University of California, Irvine, School of Medicine, Irvine, CA (United States); Quinlan-Davidson, Sean [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Department of Radiation Oncology, McMaster University, Juravinski Cancer Centre, Hamilton, Ontario (Canada); Filion, Edith J. [Department of Radiation Oncology, Stanford University School of Medicine, Stanford, CA (United States); Departement de Medecine, Service de Radio-Oncologie, Centre Hospitalier de l' Universite de Montreal, Montreal, Quebec (Canada); Wakelee, Heather A.; Colevas, A. Dimitrios [Department of Medicine, Division of Oncology, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); Whyte, Richard I. [Department of Cardiothoracic Surgery, Division of General Thoracic Surgery, Stanford University School of Medicine, Stanford, CA (United States); Stanford Cancer Institute, Stanford University School of Medicine, Stanford, CA (United States); and others

    2012-09-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18-25 Gy) (Group 1), and larger tumors (gross tumor volume {>=}12 mL) received multifraction regimens with BED {>=}100 Gy (total dose, 50-60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  11. Effectiveness of stereotactic body radiotherapy for hepatocellular carcinoma with portal vein and/or inferior vena cava tumor thrombosis.

    Directory of Open Access Journals (Sweden)

    Mian Xi

    Full Text Available BACKGROUND: To report the feasibility, efficacy, and toxicity of stereotactic body radiotherapy (SBRT for the treatment of portal vein tumor thrombosis (PVTT and/or inferior vena cava tumor thrombosis (IVCTT in patients with advanced hepatocellular carcinoma (HCC. MATERIALS AND METHODS: Forty-one patients treated with SBRT using volumetric modulated arc therapy (VMAT for HCC with PVTT/IVCTT between July 2010 and May 2012 were analyzed. Of these, 33 had PVTT and 8 had IVCTT. SBRT was designed to target the tumor thrombosis and deliver a median total dose of 36 Gy (range, 30-48 Gy in six fractions during two weeks. RESULTS: The median follow-up was 10.0 months. At the time of analysis, 15 (36.6% achieved complete response, 16 (39.0% achieved partial response, 7 (17.1% patients were stable, and three (7.3% patients showed progressive disease. No treatment-related Grade 4/5 toxicity was seen within three months after SBRT. One patient had Grade 3 elevation of bilirubin. The one-year overall survival rate was 50.3%, with a median survival of 13.0 months. The only independent predictive factor associated with better survival was response to radiotherapy. CONCLUSIONS: VMAT-based SBRT is a safe and effective treatment option for PVTT/IVCTT in HCC. Prospective randomized controlled trials are warranted to validate the role of SBRT in these patients.

  12. Stereotactic Fractionated Radiotherapy and LINAC Radiosurgery in the Treatment of Vestibular Schwannoma-Report About Both Stereotactic Methods From a Single Institution

    International Nuclear Information System (INIS)

    Kopp, Christine; Fauser, Claudius; Mueller, Axel; Astner, Sabrina T.; Jacob, Vesna; Lumenta, Christianto; Meyer, Bernhard; Tonn, Joerg-Christian; Molls, Michael; Grosu, Anca-Ligia

    2011-01-01

    Purpose: To evaluate tumor control and side effects associated with radiosurgery (RS) and stereotactic fractionated radiotherapy (SFR) for vestibular schwannomas (VSs) in a group of patients treated at the same institution. Methods and Materials: Between May 1997 and June 2007, 115 consecutive cases of VS were treated in our department. The SFR group (47 patients), including larger tumors (maximum diameter >1.5 cm), received a total dose of 54 Gy at 1.8 Gy per fraction. The RS group (68 patients, maximum diameter <1.5 cm) received a total dose of 12 Gy at the 100% isodose. Evaluation included serial imaging tests (magnetic resonance imaging) and neurologic and functional hearing examinations. Results: The tumor control rate was 97.9% in the SFR group for a mean follow-up time of 32.1 months and 98.5% in the RS group for a mean follow-up time of 30.1 months. Hearing function was preserved after RS in 85% of the patients and after SFR in 79%. Facial and trigeminal nerve function remained mostly unaffected after SFR. After RS, new trigeminal neuropathy occurred in 9 of 68 patients (13%). Conclusions: A high tumor control rate and low number of side effects are registered after SFR and RS of VS. These results confirm that considering tumor diameter, both RS and SFR are good treatment modalities for VS.

  13. Aftereffect of radiotherapy of upper aero-digestive tracts in odontological care

    International Nuclear Information System (INIS)

    Schiochet, Luc

    2010-01-01

    In its first part, this thesis proposes a detailed presentation of the upper aero-digestive tract cancer. The author defines the cancerous process, describes anatomic aspects, and discusses epidemiological aspects (occurrence, mortality, survival, and epidemiological data in different countries). In the second part, the author discusses the role of radiotherapy and of dental surgery in taking a cancerous patient into care (general principles of radiotherapy, therapeutic options and choices, association of radiotherapy, chemotherapy and surgery). Principles of radiotherapy are then more precisely addressed: physical principles (X rays, gamma rays, electrons, neutrons, and protons), radioactivity doses, radiotherapy effect, main equipment, radiotherapy techniques (conformational or intensity-modulated radiotherapy, computed tomography, Cyberknife, external radiotherapy, brachytherapy). The third part addresses early oral-facial complications induced by radiotherapy: factors favouring these complications, nervous effects, effects on the blood system and on the skin, hyposialia and xerostomia, radio-induced mucositis of upper aero-digestive tracts. The next part addresses late effects: late cutaneous after-effects, late radio-mucositis, limitation of mouth opening, tooth decays, osteoradionecrosis. The last part addresses the role of the dental surgeon in taking into care a patient whose head and neck have been irradiated: role before irradiation, during irradiation, and after irradiation [fr

  14. [Doses to organs at risk in conformational and stereotactic body radiation therapy: Liver].

    Science.gov (United States)

    Debbi, K; Janoray, G; Scher, N; Deutsch, É; Mornex, F

    2017-10-01

    The liver is an essential organ that ensures many vital functions such as metabolism of bilirubin, glucose, lipids, synthesis of coagulation factors, destruction of many toxins, etc. The hepatic parenchyma can be irradiated during the management of digestive tumors, right basithoracic, esophagus, abdomen in toto or TBI. In addition, radiotherapy of the hepatic area, which is mainly stereotactic, now occupies a central place in the management of primary or secondary hepatic tumors. Irradiation of the whole liver, or part of it, may be complicated by radiation-induced hepatitis. It is therefore necessary to respect strict dosimetric constraints both in stereotactic and in conformational irradiation in order to limit the undesired irradiation of the hepatic parenchyma which may vary according to the treatment techniques, the basic hepatic function or the lesion size. The liver is an organ with a parallel architecture, so the average tolerable dose in the whole liver should be considered rather than the maximum tolerable dose at one point. The purpose of this article is to propose a development of dose recommendations during conformation or stereotactic radiotherapy of the liver. Copyright © 2017 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  15. Reirradiation of recurrent node-positive non-small cell lung cancer after previous stereotactic radiotherapy for stage I disease. A multi-institutional treatment recommendation

    Energy Technology Data Exchange (ETDEWEB)

    Nieder, Carsten [Nordland Hospital, Department of Oncology and Palliative Medicine, Bodoe (Norway); University of Tromsoe, Institute of Clinical Medicine, Faculty of Health Sciences, Tromsoe (Norway); Ruysscher, Dirk de [MAASTRO Clinic, Department of Radiation Oncology, Maastricht (Netherlands); Gaspar, Laurie E. [University of Colorado School of Medicine, Department of Radiation Oncology, Aurora, CO (United States); Guckenberger, Matthias [University Hospital Zurich, Department of Radiation Oncology, Zurich (Switzerland); Mehta, Minesh P. [Miami Cancer Institute, Department of Radiation Oncology, Miami, FL (United States); Cheung, Patrick; Sahgal, Arjun [Sunnybrook Health Sciences Centre and University of Toronto, Department of Radiation Oncology, Toronto (Canada)

    2017-07-15

    Practice guidelines have been developed for early-stage and locally advanced non-small cell lung cancer (NSCLC). However, many common clinical scenarios still require individualized decision making. This is true for locoregional relapse after initial stereotactic radiotherapy (stereotactic body radiation therapy or stereotactic ablative radiotherapy; SBRT or SABR), an increasingly utilized curative treatment option for stage I NSCLC. A consortium of expert radiation oncologists was established with the aim of providing treatment recommendations. In this scenario, a case was distributed to six radiation oncologists who provided their institutions' treatment recommendations. In this case, a patient developed local and mediastinal relapse after SABR (45 Gy, 3 fractions), comparable to the tumor burden in de novo stage IIIA NSCLC. Treatment recommendations were tabulated and a consensus conclusion was developed. Three institutions recommended evaluation for surgery. If the patient was not a surgical candidate, and/or refused surgery, definitive chemoradiation was recommended, including retreating the primary to full dose. European participants were more in favor of a non-surgical approach. None of the participants were reluctant to prescribe reirradiation, but two institutions prescribed doses lower than 60 Gy. Platinum-based doublets together with intensity-modulated radiotherapy were preferred. The institutional recommendations reflect the questions and uncertainties discussed in current stage III guidelines. All institutions agreed that previous SABR is not a contraindication for salvage chemoradiation. In the absence of high-quality prospective trials for recurrent NSCLC, all treatment options recommended in current guidelines for stage III disease can be considered in clinical scenarios such as this. (orig.) [German] Fuer fruehe und lokal fortgeschrittene Stadien des nicht-kleinzelligen Bronchialkarzinoms (NSCLC) wurden Behandlungsleitlinien publiziert

  16. The role of stereotactic radiation therapy and whole-brain radiotherapy in the treatment of multiple brain metastases

    International Nuclear Information System (INIS)

    Chen Xiujun; Xiao Jianping; Li Xiangpan; Jiang Xuesong; Zhang Ye; Xu Yingjie; Dai Jianrong; Li Yexiong

    2012-01-01

    Objective: To summarize the results of stereotactic radiation therapy (SRT) with or without whole-brain radiotherapy (WBRT) in the treatment of multiple brain metastasis. Methods: From May 1995 to April 2010, totally 98 newly diagnosed multiple (2 - 13 lesions) brain metastases patients were treated in our centre. Forty-four patients were treated with SRT alone and 54 with SRT + WBRT. Dose fractionation schemes were 15 -26 Gy in 1 fraction or 24.0 -52.5 Gy in 2 - 15 fractions with 3.5 - 12.0 Gy per fraction, depending on the tumor volume, location, and history of prior irradiation. Kaplan-Meier and Cox proportional hazards regression analyses were used for survival analysis. The median age of the whole group was 55 years. The survival time was calculated from the date of radiation treatment to the day of death by any cause. Results: The median follow-up time for the whole group was 12 months, and the follow-up rate was 100%. The median overall survival time was 13.5 months for the whole group, there was no difference between SRT alone group and SRT + WBRT group (13.0 months vs. 13.5 months, χ 2 =0.31, P =0.578). The Karnofsky Performance Score (KPS) at the time of treatment (χ 2 =6.25, P =0.012), the interval between the diagnosis of the primary tumor and brain metastases (χ 2 =7.34, P =0.025) and the status of extracranial metastases (χ 2 =4.20, P =0.040) were independent prognosis factors for survival in multivariate analyses. Conclusions: Stereotactic radiation therapy is an effective and alternative treatment choice for multiple brain metastases. (authors)

  17. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver.

    Science.gov (United States)

    Wulf, Jörn; Hädinger, Ulrich; Oppitz, Ulrich; Thiele, Wibke; Flentje, Michael

    2003-02-01

    Previous analyses of target reproducibility in extracranial stereotactic radiotherapy have revealed standard security margins for planning target volume (PTV) definition of 5mm in axial and 5-10mm in longitudinal direction. In this study the reproducibility of the clinical target volume (CTV) of lung and liver tumors within the PTV over the complete course of hypofractionated treatment is evaluated. The impact of target mobility on dose to the CTV is assessed by dose-volume histograms (DVH). Twenty-two pulmonary and 21 hepatic targets were treated with three stereotactic fractions of 10 Gy to the PTV-enclosing 100%-isodose with normalization to 150% at the isocenter. A conformal dose distribution was related to the PTV, which was defined by margins of 5-10mm added to the CTV. Prior to each fraction a computed tomography (CT)-simulation over the complete target volume was performed resulting in a total of 60 CT-simulations for lung and 58 CT-simulations for hepatic targets. The CTV from each CT-simulation was segmented and matched with the CT-study used for treatment planning. A DVH of the simulated CTV was calculated for each fraction. The target coverage (TC) of dose to the simulated CTV was defined as the proportion of the CTV receiving at least the reference dose (100%). A decrease of TC to or=95% at each fraction of treatment. Pulmonary targets with increased breathing mobility and liver tumors >100 cm(3) are at risk for target deviation exceeding the standard security margins for PTV-definition at least for one fraction and require individual evaluation of sufficient margins.

  18. Robotic radiosurgery. Treating tumors that move with respiration

    International Nuclear Information System (INIS)

    Urschel, Harold C. Jr.; Kresl, John J.; Luketich, James D.; Papiez, Lech; Timmerman, Robert D.; Schulz, Raymond A.

    2007-01-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife registered Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife using a

  19. Robotic radiosurgery. Treating tumors that move with respiration

    Energy Technology Data Exchange (ETDEWEB)

    Urschel, Harold C. Jr. [Baylor University Medical Center, Dallas, TX (United States). Chair of Cardiovascular and Thoracic Surgical Research, Education and Clinical Excellence; Kresl, John J. [Arizona Oncology Services at St. Joseph' s Hospital and Medical Center, Phoenix, AZ (United States). Dept. of Radiation Oncology; Luketich, James D. [University of Pittsburgh Medical Center PUH, Pittsburgh, PA (United States). The Heart, Lung and Esophageal Surgery Inst.; Papiez, Lech; Timmerman, Robert D. [University of Texas Southwestern Medical Center, Dallas, TX (United States). Dept. of Radiation Oncology; Schulz, Raymond A. (eds.)

    2007-07-01

    Addresses in detail all aspects of the use of robotic radiosurgery to treat tumors of the lung, liver, and pancreas Includes full consideration of tumor tracking techniques, dosimetry, radiobiology, and fiducial placement strategies Written by leading experts Includes many high quality illustrations Stereotactic radiosurgery continues to evolve in ways that allow this powerful technology to reach and treat more tumors in more patients. This volume in the Robotic Radiosurgery series is devoted to theory and practice in the emerging field of stereotactic radiosurgery (also called stereotactic body radiation therapy) for extracranial tumors, particularly those that move as patients breathe. The book is divided into six sections. The first three sections address tumor motion due to respiration and tumor tracking techniques; dosimetry, radiobiology, and imaging; and fiducial placement systems. The fourth and fifth sections then discuss in depth the use of robotic radiosurgery to treat lung and abdominal tumors, respectively, and a final section explains emerging concepts and techniques. Within this framework, detailed information is provided on the technology and methodology for delivery of high doses of radiation to moving targets, radiobiological and radiological principles, and the challenges faced by clinicians performing extracranial stereotactic radiosurgery. Furthermore, there are thorough reviews of the general clinical literature on stereotactic radiation treatment of tumors of the lungs, liver, and pancreas, and the latest clinical data from clinicians conducting clinical studies using the CyberKnife {sup registered} Robotic Radiosurgery System. Special attention is given to the frameless robotic radiosurgery device known as the CyberKnife, the only image-guided radiosurgery system that utilizes intelligent robotics to track, detect, and correct for changes in tumor position during treatments. Tumors that move with respiration are treated with the CyberKnife

  20. Fractionated Stereotactic Radiotherapy in Patients With Optic Nerve Sheath Meningioma

    Energy Technology Data Exchange (ETDEWEB)

    Paulsen, Frank, E-mail: frank.paulsen@med.uni-tuebingen.de [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Doerr, Stefan [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Wilhelm, Helmut [Department of Ophthalmology, University of Tuebingen, Tuebingen (Germany); Becker, Gerd [Department of Radiation Oncology, Klinik am Eichert, Goeppingen (Germany); Bamberg, Michael [Department of Radiation Oncology, University of Tuebingen, Tuebingen (Germany); Classen, Johannes [Department of Radiation Oncology, St. Vincentius-Kliniken, Karlsruhe (Germany)

    2012-02-01

    Purpose: To evaluate the effectiveness of fractionated stereotactic radiotherapy (SFRT) in the treatment of optic nerve sheath meningioma (ONSM). Methods and Materials: Between 1993 and 2005, 109 patients (113 eyes) with primary (n = 37) or secondary (n = 76) ONSM were treated according to a prospective protocol with SFRT to a median dose of 54 Gy. All patients underwent radiographic, ophthalmologic, and endocrine analysis before and after SFRT. Radiographic response, visual control, and late side effects were endpoints of the analysis. Results: Median time to last clinical, radiographic, and ophthalmologic follow up was 30.2 months (n = 113), 42.7 months (n = 108), and 53.7 months (n = 91), respectively. Regression of the tumor was observed in 5 eyes and progression in 4 eyes, whereas 104 remained stable. Visual acuity improved in 12, deteriorated in 11, and remained stable in 68 eyes. Mean visual field defects reduced from 33.6% (n = 90) to 17.8% (n = 56) in ipsilateral and from 10% (n = 94) to 6.7% (n = 62) in contralateral eyes. Ocular motility improved in 23, remained stable in 65, and deteriorated in 3 eyes. Radiographic tumor control was 100% at 3 years and 98% at 5 years. Visual acuity was preserved in 94.8% after 3 years and in 90.9% after 5 years. Endocrine function was normal in 90.8% after 3 years and in 81.3% after 5 years. Conclusions: SFRT represents a highly effective treatment for ONSM. Interdisciplinary counseling of the patients is recommended. Because of the high rate of preservation of visual acuity we consider SFRT the standard approach for the treatment of ONSM. Prolonged observation is warranted to more accurately assess late visual impairment. Moderate de-escalation of the radiation dose might improve the preservation of visual acuity and pituitary gland function.

  1. Pattern of Progression after Stereotactic Body Radiotherapy for Oligometastatic Prostate Cancer Nodal Recurrences.

    Science.gov (United States)

    Ost, P; Jereczek-Fossa, B A; Van As, N; Zilli, T; Tree, A; Henderson, D; Orecchia, R; Casamassima, F; Surgo, A; Miralbell, R; De Meerleer, G

    2016-09-01

    To report the relapse pattern of stereotactic body radiotherapy (SBRT) for oligorecurrent nodal prostate cancer (PCa). PCa patients with ≤3 lymph nodes (N1/M1a) at the time of recurrence were treated with SBRT. SBRT was defined as a radiotherapy dose of at least 5 Gy per fraction to a biological effective dose of at least 80 Gy to all metastatic sites. Distant progression-free survival was defined as the time interval between the first day of SBRT and appearance of new metastatic lesions, outside the high-dose region. Relapses after SBRT were recorded and compared with the initially treated site. Secondary end points were local control, time to palliative androgen deprivation therapy and toxicity scored using the Common Terminology Criteria for Adverse Events v4.0. Overall, 89 metastases were treated in 72 patients. The median distant progression-free survival was 21 months (95% confidence interval 16-25 months) with 88% of patients having ≤3 metastases at the time of progression. The median time from first SBRT to the start of palliative androgen deprivation therapy was 44 months (95% confidence interval 17-70 months). Most relapses (68%) occurred in nodal regions. Relapses after pelvic nodal SBRT (n = 36) were located in the pelvis (n = 14), retroperitoneum (n = 1), pelvis and retroperitoneum (n = 8) or in non-nodal regions (n = 13). Relapses after SBRT for extrapelvic nodes (n = 5) were located in the pelvis (n = 1) or the pelvis and retroperitoneum (n = 4). Late grade 1 and 2 toxicity was observed in 17% (n = 12) and 4% of patients (n = 3). SBRT for oligometastatic PCa nodal recurrences is safe. Most subsequent relapses are again nodal and oligometastatic. Copyright © 2016 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  2. Dose variations caused by setup errors in intracranial stereotactic radiotherapy: A PRESAGE study

    International Nuclear Information System (INIS)

    Teng, Kieyin; Gagliardi, Frank; Alqathami, Mamdooh; Ackerly, Trevor; Geso, Moshi

    2014-01-01

    Stereotactic radiotherapy (SRT) requires tight margins around the tumor, thus producing a steep dose gradient between the tumor and the surrounding healthy tissue. Any setup errors might become clinically significant. To date, no study has been performed to evaluate the dosimetric variations caused by setup errors with a 3-dimensional dosimeter, the PRESAGE. This research aimed to evaluate the potential effect that setup errors have on the dose distribution of intracranial SRT. Computed tomography (CT) simulation of a CIRS radiosurgery head phantom was performed with 1.25-mm slice thickness. An ideal treatment plan was generated using Brainlab iPlan. A PRESAGE was made for every treatment with and without errors. A prescan using the optical CT scanner was carried out. Before treatment, the phantom was imaged using Brainlab ExacTrac. Actual radiotherapy treatments with and without errors were carried out with the Novalis treatment machine. Postscan was performed with an optical CT scanner to analyze the dose irradiation. The dose variation between treatments with and without errors was determined using a 3-dimensional gamma analysis. Errors are clinically insignificant when the passing ratio of the gamma analysis is 95% and above. Errors were clinically significant when the setup errors exceeded a 0.7-mm translation and a 0.5° rotation. The results showed that a 3-mm translation shift in the superior-inferior (SI), right-left (RL), and anterior-posterior (AP) directions and 2° couch rotation produced a passing ratio of 53.1%. Translational and rotational errors of 1.5 mm and 1°, respectively, generated a passing ratio of 62.2%. Translation shift of 0.7 mm in the directions of SI, RL, and AP and a 0.5° couch rotation produced a passing ratio of 96.2%. Preventing the occurrences of setup errors in intracranial SRT treatment is extremely important as errors greater than 0.7 mm and 0.5° alter the dose distribution. The geometrical displacements affect dose delivery

  3. Stereotactic body radiation therapy (SBRT) in the treatment of liver metastases: State of the art

    International Nuclear Information System (INIS)

    De Bari, B.; Guillet, M.; Mornex, F.

    2011-01-01

    Liver metastases are frequently found in oncologic patients. Chemotherapy is the standard treatment in pluri-metastatic patients, with the possibility to obtain a clear improvement of their prognosis. Local treatment (surgery, radiofrequency, cryo-therapy, radiotherapy, etc.) could be proposed for oligo-metastatic patients, particularly for those with a good prognosis. Historically, radiation therapy has had a limited role in the treatment of liver metastases because of its toxicity when whole liver irradiation was delivered. Improvements in the knowledge of liver radiobiology and radio-pathology as well as technical innovations in delivering radiation therapy are the basis of the modern partial liver irradiation concept. In this historical and therapeutic landscape, extracranial stereotactic radiation therapy is particularly interesting for the treatment of liver metastases. This review summarises published data on stereotactic radiotherapy for the treatment of liver metastases. (authors)

  4. Single Fraction Stereotactic Ablative Body Radiotherapy for Oligometastasis: Outcomes from 132 Consecutive Patients.

    Science.gov (United States)

    Gandhidasan, S; Ball, D; Kron, T; Bressel, M; Shaw, M; Chu, J; Chander, S; Wheeler, G; Plumridge, N; Chesson, B; David, S; Siva, S

    2018-03-01

    Stereotactic ablative body radiotherapy (SABR) is currently used to treat oligometastases, but the optimum dose/fractionation schedule is unknown. In this study, we evaluated outcomes after single fraction SABR in patients with oligometastatic disease. Single institutional retrospective review of patients treated with single fraction SABR for one to three oligometastases between 2010 and 2015. The primary outcome was freedom from widespread disease defined as distant recurrence not amenable to surgery or SABR; or recurrence with four or more metastases. In total, 186 treatments were delivered in 132 patients. The two most common target sites were lung (51%) and bone (40%). The most frequent single fraction prescription dose was 26 Gy (47%). The most common primary malignancy was genitourinary (n = 46 patients). Freedom from widespread disease was 75% at 1 year (95% confidence interval 67-83%) and 52% at 2 years (95% confidence interval 42-63%). Freedom from local progression at 1 year was 90% (95% confidence interval 85-95%) and at 2 years was 84% (95% confidence interval 77-91%). A compression fracture of the lumbar vertebra was the only grade 3+ treatment-related toxicity. Single fraction SABR is associated with a high rate of freedom from widespread disease, favourable local control and low toxicity comparable with historic multi-fraction SABR reports. Copyright © 2017 The Royal College of Radiologists. Published by Elsevier Ltd. All rights reserved.

  5. Clinical experience with image-guided robotic radiosurgery (the Cyberknife) in the treatment of brain and spinal cord tumors

    International Nuclear Information System (INIS)

    Chang, S.D.; Murphy, M.; Geis, P.; Martin, D.P.; Hancock, S.L.; Doty, J.R.; Adler, J.R. Jr.

    1998-01-01

    The Cyberknife is an image-guided ''frameless'' dedicated radiosurgical device. This instrument has several distinct advantages over frame-based systems, including improved patient comfort, increased treatment degrees of freedom, and the potential to target extracranial lesions. Clinical results thus far with respect to the treatment of malignant intracranial tumors has been promising. Additionally, the Cyberknife will likely revolutionize the application of radiosurgery to extracranial sites. A description of the components, treatment planning, and clinical results of the Cyberknife will be reviewed. (author)

  6. Stereotactic radiosurgery planning with ictal SPECT images

    International Nuclear Information System (INIS)

    Ackerly, T.; RMIT University, Bundoora, VIC; Geso, M.; O'Keefe, G.; Smith, R.

    2004-01-01

    This paper is motivated by a clinical requirement to utilise ictal SPECT images for target localisation in stereotactic radiosurgery treatment planning using the xknife system which only supports CT and MRI images. To achieve this, the SPECT images were converted from raw (pixel data only) format into a part 10 compliant DICOM CT fileset. The minimum requirements for the recasting of a raw format image as DICOM CT or MRI data set are described in detail. The method can be applied to the importation of raw format images into any radiotherapy treatment planning system that supports CT or MRI import. It is demonstrated that the combination of the low spatial resolution SPECT images, depicting functional information, with high spatial resolution MRI images, which show the structural information, is suitable for stereotactic radiosurgery treatment planning. Copyright (2004) Australasian College of Physical Scientists and Engineers in Medicine

  7. Postoperative modified stereotactic radiotherapy using a micro-multileaf collimator in patients with malignant glioma.

    Science.gov (United States)

    Isaka, Toshihiko; Nishiyama, Kinji; Nakagawa, Hidemitsu; Suzuki, Tsuyoshi; Wada, Kouichi

    2002-06-01

    To achieve local control of malignant glioma, we designed a postoperative stereotactic radiotherapy using a micro-multileaf collimator (micro-MLC). The purpose of this study was to clarify the feasibility of this treatment. The treatment was performed in six patients who met the following eligibility criteria: (1) supratentorial tumor, (2) residual tumor volume or = 70. The three planning target volumes (PTVs), which consisted of restricted PTV (RPTV), intermediate PTV (IPTV), and extended PTV (EPTV), defined as the residual tumor plus a 1 cm, 2 cm, and 3 cm margins, respectively, and total dose delivery of 60-68 Gy, 52-60 Gy, and 44-52 Gy to the isocenters of RPTV, IPTV, and EPTV, respectively, in 4 Gy per fraction at five fractions per week, were established. The beam arrangement and the conformal blockade with a micro-MLC for the optimal treatment plan were designed. The treatment plans showed the high dose conformation to EPTV, the appropriate dose gradients in the three PTVs with the high dose homogeneity to RPTV, and the tolerated dose to critical structures. Following the plans, treatment was performed. The clinical findings more than 12 months after the treatment supported its possible use. We conclude that this treatment is feasible at least in selected patients.

  8. Frameless stereotactic radiosurgery of a solitary liver metastasis using active breathing control and stereotactic ultrasound

    International Nuclear Information System (INIS)

    Boda-Heggemann, J.; Walter, C.; Mai, S.; Dobler, B.; Wenz, F.; Lohr, F.; Dinter, D.

    2006-01-01

    Background and purpose: radiosurgery of liver metastases is effective but a technical challenge due to respiration-induced movement. The authors report on the initial experience of the combination of active breathing control (ABC registered ) with stereotactic ultrasound (B-mode acquisition and targeting [BAT registered ]) for frameless radiosurgery. Patient and methods: a patient with a solitary, inoperable liver metastasis from cholangiocellular carcinoma is presented. ABC registered was used for tumor/liver immobilization. Tumor/liver position was controlled and corrected using ultrasound (BAT registered ). The tumor was irradiated with a single dose of 24 Gy. Results: using ABC registered , the motion of the tumor was significantly reduced and the overall positioning error was registered allowed a rapid localization of the lesion during breath hold which could be performed without difficulties for 20 s. Overall treatment time was acceptable (30 min). Conclusion: frameless stereotactic radiotherapy with the combination of ABC registered and BAT registered allows the delivery of high single doses to targets accessible to ultrasound with high precision comparable to a frame-based approach. (orig.)

  9. Fractionated vs. single-fraction stereotactic radiotherapy in patients with vestibular schwannoma. Hearing preservation and patients' self-reported outcome based on an established questionnaire

    International Nuclear Information System (INIS)

    Kessel, Kerstin A.; Fischer, Hanna; Vogel, Marco M.E.; Combs, Stephanie E.; Oechsner, Markus; Bier, Henning; Meyer, Bernhard

    2017-01-01

    Stereotactic radiotherapy (RT) has been established as a valid treatment alternative in patients with vestibular schwannoma (VS). There is ongoing controversy regarding the optimal fractionation. Hearing preservation may be the primary goal for patients with VS, followed by maintenance of quality of life (QoL). From 2002 to 2015, 184 patients with VS were treated with radiosurgery (RS) or fractionated stereotactic radiotherapy (FSRT). A survey on current symptoms and QoL was conducted between February and June 2016. Median follow-up after RT was 7.5 years (range 0-14.4 years). Mean overall survival (OS) after RT was 31.1 years, with 94 and 87% survival at 5 and 10 years, respectively. Mean progression-free survival (PFS) was 13.3 years, with 5- and 10-year PFS of 92%. Hearing could be preserved in RS patients for a median of 36.3 months (range 2.3-13.7 years). Hearing worsened in 17 (30%) cases. Median hearing preservation for FSRT was 48.7 months (range 0.0-13.8 years); 29 (23%) showed hearing deterioration. The difference in hearing preservation was not significant between RS and FSRT (p = 0.3). A total of 123/162 patients participated in the patient survey (return rate 76%). The results correlate well with the information documented in the patient files for tinnitus and facial and trigeminal nerve toxicity. Significant differences appeared regarding hearing impairment, gait uncertainty, and imbalance. These data confirm that RS and FSRT are comparable in terms of local control for VS. RS should be reserved for smaller lesions, while FSRT can be offered independently of tumor size. Patient self-reported outcome during follow-up is of high value. The established questionnaire could be validated in the independent cohort. (orig.) [de

  10. A Multidisciplinary Evaluation of a Web-based eLearning Training Programme for SAFRON II (TROG 13.01): a Multicentre Randomised Study of Stereotactic Radiotherapy for Lung Metastases.

    Science.gov (United States)

    Pham, D; Hardcastle, N; Foroudi, F; Kron, T; Bressel, M; Hilder, B; Chesson, B; Oates, R; Montgomery, R; Ball, D; Siva, S

    2016-09-01

    In technically advanced multicentre clinical trials, participating centres can benefit from a credentialing programme before participating in the trial. Education of staff in participating centres is an important aspect of a successful clinical trial. In the multicentre study of fractionated versus single fraction stereotactic ablative body radiotherapy in lung oligometastases (TROG 13.01), knowledge transfer of stereotactic ablative body radiotherapy techniques to the local multidisciplinary team is intended as part of the credentialing process. In this study, a web-based learning platform was developed to provide education and training for the multidisciplinary trial teams at geographically distinct sites. A web-based platform using eLearning software consisting of seven training modules was developed. These modules were based on extracranial stereotactic theory covering the following discrete modules: Clinical background; Planning technique and evaluation; Planning optimisation; Four-dimensional computed tomography simulation; Patient-specific quality assurance; Cone beam computed tomography and image guidance; Contouring organs at risk. Radiation oncologists, medical physicists and radiation therapists from hospitals in Australia and New Zealand were invited to participate in this study. Each discipline was enrolled into a subset of modules (core modules) and was evaluated before and after completing each module. The effectiveness of the eLearning training will be evaluated based on (i) knowledge retention after participation in the web-based training and (ii) confidence evaluation after participation in the training. Evaluation consisted of a knowledge test and confidence evaluation using a Likert scale. In total, 130 participants were enrolled into the eLearning programme: 81 radiation therapists (62.3%), 27 medical physicists (20.8%) and 22 radiation oncologists (16.9%). There was an average absolute improvement of 14% in test score (P 4 weeks) after

  11. Situation of radiotherapy in 2010 - context and methods, data for 2003/2010, synthesis

    International Nuclear Information System (INIS)

    2011-03-01

    Illustrated by data tables and figures, this report first gives an overview of the status and situation of European and French radiotherapy centres, and of care activity authorizations regarding external radiotherapy. It gives an overview of equipment used for treatments and for treatment preparation and delivery, and of the different treatment techniques (three dimensional conformational, intensity-modulated conformational, stereotactic, whole body radiotherapy, proton-therapy). It comments the activity of radiotherapy centres: patients (age, sessions, and treated pathologies), comments data regarding medical and paramedical personnel involved in radiotherapy, and financial data regarding radiotherapy in 2009

  12. Computed Tomography Assessment of Ablation Zone Enhancement in Patients With Early-Stage Lung Cancer After Stereotactic Ablative Radiotherapy.

    Science.gov (United States)

    Moore, William; Chaya, Yair; Chaudhry, Ammar; Depasquale, Britney; Glass, Samantha; Lee, Susan; Shin, James; Mikhail, George; Bhattacharji, Priya; Kim, Bong; Bilfinger, Thomas

    2015-01-01

    Stereotactic ablative radiotherapy (SABR) offers a curative treatment for lung cancer in patients who are marginal surgical candidates. However, unlike traditional surgery the lung cancer remains in place after treatment. Thus, imaging follow-up for evaluation of recurrence is of paramount importance. In this retrospective designed Institutional Review Board-approved study, follow-up contrast-enhanced computed tomography (CT) exams were performed on sixty one patients to evaluate enhancement pattern in the ablation zone at 1, 3, 6, and 12 months after SABR. Eleven patients had recurrence within the ablation zone after SABR. The postcontrast enhancement in the recurrence group showed a washin and washout phenomenon, whereas the radiation-induced lung injury group showed continuous enhancement suggesting an inflammatory process. The textural feature of the ablation zone of enhancement and perfusion as demonstrated in computed tomography nodule enhancement may allow early differentiation of recurrence from radiation-induced lung injury in patients' status after SABR or primary lung cancer.

  13. Integral Dose and Radiation-Induced Secondary Malignancies: Comparison between Stereotactic Body Radiation Therapy and Three-Dimensional Conformal Radiotherapy

    Directory of Open Access Journals (Sweden)

    Stefano G. Masciullo

    2012-11-01

    Full Text Available The aim of the present paper is to compare the integral dose received by non-tumor tissue (NTID in stereotactic body radiation therapy (SBRT with modified LINAC with that received by three-dimensional conformal radiotherapy (3D-CRT, estimating possible correlations between NTID and radiation-induced secondary malignancy risk. Eight patients with intrathoracic lesions were treated with SBRT, 23 Gy × 1 fraction. All patients were then replanned for 3D-CRT, maintaining the same target coverage and applying a dose scheme of 2 Gy × 32 fractions. The dose equivalence between the different treatment modalities was achieved assuming α/β = 10Gy for tumor tissue and imposing the same biological effective dose (BED on the target (BED = 76Gy10. Total NTIDs for both techniques was calculated considering α/β = 3Gy for healthy tissue. Excess absolute cancer risk (EAR was calculated for various organs using a mechanistic model that includes fractionation effects. A paired two-tailed Student t-test was performed to determine statistically significant differences between the data (p ≤ 0.05. Our study indicates that despite the fact that for all patients integral dose is higher for SBRT treatments than 3D-CRT (p = 0.002, secondary cancer risk associated to SBRT patients is significantly smaller than that calculated for 3D-CRT (p = 0.001. This suggests that integral dose is not a good estimator for quantifying cancer induction. Indeed, for the model and parameters used, hypofractionated radiotherapy has the potential for secondary cancer reduction. The development of reliable secondary cancer risk models seems to be a key issue in fractionated radiotherapy. Further assessments of integral doses received with 3D-CRT and other special techniques are also strongly encouraged.

  14. A linac-based stereotactic irradiation technique of uveal melanoma

    International Nuclear Information System (INIS)

    Dieckmann, Karin; Bogner, Joachim; Georg, Dietmar; Zehetmayer, Martin; Kren, Gerhard; Poetter, Richard

    2001-01-01

    Purpose: To describe a stereotactic irradiation technique for uveal melanomas performed at a linac, based on a non-invasive eye fixation and eye monitoring system. Methods: For eye immobilization a light source system is integrated in a standard stereotactic mask system in front of the healthy eye: During treatment preparation (computed tomography/magnetic resonance imaging) as well as for treatment delivery, patients are instructed to gaze at the fixation light source. A mini-video camera monitors the pupil center position of the diseased eye. For treatment planning and beam delivery standard stereotactic radiotherapy equipment is used. If the pupil center deviation from a predefined 'zero-position' exceeds 1 mm (for more than 2 s), treatment delivery is interrupted. Between 1996 and 1999 60 patients with uveal melanomas, where (i) tumor height exceeded 7 mm, or (ii) tumor height was more than 3 mm, and the central tumor distance to the optic disc and/or the macula was less than 3 mm, have been treated. A total dose of 60 or 70 Gy has been given in 5 fractions within 10 days. Results: The repositioning accuracy in the mask system is 0.47±0.36 mm in rostral-occipital direction, 0.75±0.52 mm laterally, and 1.12±0.96 mm in vertical direction. An eye movement analysis performed for 23 patients shows a pupil center deviation from the 'zero' position<1 mm in 91% of all cases investigated. In a theoretical analysis, pupil center deviations are correlated with GTV 'movements'. For a pupil center deviation of 1 mm (rotation of the globe of 5 degree sign ) the GTV is still encompassed by the 80% isodose in 94%. Conclusion: For treatments of uveal melanomas, linac-based stereotactic radiotherapy combined with a non-invasive eye immobilization and monitoring system represents a feasible, accurate and reproducible method. Besides considerable technical requirements, the complexity of the treatment technique demands an interdisciplinary team continuously dedicated to this

  15. Stereotactic ablative radiotherapy for comprehensive treatment of oligometastatic tumors (SABR-COMET): Study protocol for a randomized phase II trial

    International Nuclear Information System (INIS)

    Palma, David A; Griffioen, GwendolynHMJ; Gaede, Stewart; Slotman, Ben; Senan, Suresh; Haasbeek, Cornelis J A; Rodrigues, George B; Dahele, Max; Lock, Michael; Yaremko, Brian; Olson, Robert; Liu, Mitchell; Panarotto, Jason

    2012-01-01

    Stereotactic ablative radiotherapy (SABR) has emerged as a new treatment option for patients with oligometastatic disease. SABR delivers precise, high-dose, hypofractionated radiotherapy, and achieves excellent rates of local control. Survival outcomes for patients with oligometastatic disease treated with SABR appear promising, but conclusions are limited by patient selection, and the lack of adequate controls in most studies. The goal of this multicenter randomized phase II trial is to assess the impact of a comprehensive oligometastatic SABR treatment program on overall survival and quality of life in patients with up to 5 metastatic cancer lesions, compared to patients who receive standard of care treatment alone. After stratification by the number of metastases (1-3 vs. 4-5), patients will be randomized between Arm 1: current standard of care treatment, and Arm 2: standard of care treatment + SABR to all sites of known disease. Patients will be randomized in a 1:2 ratio to Arm 1:Arm 2, respectively. For patients receiving SABR, radiotherapy dose and fractionation depends on the site of metastasis and the proximity to critical normal structures. This study aims to accrue a total of 99 patients within four years. The primary endpoint is overall survival, and secondary endpoints include quality of life, toxicity, progression-free survival, lesion control rate, and number of cycles of further chemotherapy/systemic therapy. This study will provide an assessment of the impact of SABR on clinical outcomes and quality of life, to determine if long-term survival can be achieved for selected patients with oligometastatic disease, and will inform the design of a possible phase III study. Clinicaltrials.gov identifier: NCT01446744

  16. Enhanced intrinsic radiosensitivity after treatment with stereotactic radiosurgery for an acoustic neuroma

    International Nuclear Information System (INIS)

    Adams, Gerard; Martin, Olga A.; Roos, Daniel E.; Lobachevsky, Pavel N.; Potter, Andrew E.; Zacest, Andrew C.; Bezak, Eva; Bonner, William M.; Martin, Roger F.; Leong, Trevor

    2012-01-01

    Enhanced radiosensitivity is an uncommon phenomenon attributable to deficient DNA repair after radiotherapy which can be assessed with the γ-H2AX assay. Reports of radiosensitivity after stereotactic radiosurgery (SRS) are uncommon. We describe a case where the clinical, radiological and laboratory findings suggest enhanced radiosensitivity after SRS for an acoustic neuroma.

  17. Determination of small field synthetic single-crystal diamond detector correction factors for CyberKnife, Leksell Gamma Knife Perfexion and linear accelerator.

    Science.gov (United States)

    Veselsky, T; Novotny, J; Pastykova, V; Koniarova, I

    2017-12-01

    The aim of this study was to determine small field correction factors for a synthetic single-crystal diamond detector (PTW microDiamond) for routine use in clinical dosimetric measurements. Correction factors following small field Alfonso formalism were calculated by comparison of PTW microDiamond measured ratio M Qclin fclin /M Qmsr fmsr with Monte Carlo (MC) based field output factors Ω Qclin,Qmsr fclin,fmsr determined using Dosimetry Diode E or with MC simulation itself. Diode measurements were used for the CyberKnife and Varian Clinac 2100C/D linear accelerator. PTW microDiamond correction factors for Leksell Gamma Knife (LGK) were derived using MC simulated reference values from the manufacturer. PTW microDiamond correction factors for CyberKnife field sizes 25-5 mm were mostly smaller than 1% (except for 2.9% for 5 mm Iris field and 1.4% for 7.5 mm fixed cone field). The correction of 0.1% and 2.0% for 8 mm and 4 mm collimators, respectively, needed to be applied to PTW microDiamond measurements for LGK Perfexion. Finally, PTW microDiamond M Qclin fclin /M Qmsr fmsr for the linear accelerator varied from MC corrected Dosimetry Diode data by less than 0.5% (except for 1 × 1 cm 2 field size with 1.3% deviation). Regarding low resulting correction factor values, the PTW microDiamond detector may be considered an almost ideal tool for relative small field dosimetry in a large variety of stereotactic and radiosurgery treatment devices. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  18. Definitive Upfront Stereotactic Ablative Radiotherapy Combined with Image-Guided, Intensity Modulated Radiotherapy (IG-IMRT or IG-IMRT Alone for Locally Advanced Non-Small Cell Lung Cancer.

    Directory of Open Access Journals (Sweden)

    Alexander Chi

    Full Text Available Image-guided (IG intensity-modulated radiotherapy (IMRT enables maximal tumor margin reduction for the sparing of organs at risk (OARs when used to treat locally advanced non-small cell lung cancer (NSCLC with definitive chemo-radiation. It also allows for the incorporation of stereotactic ablative radiotherapy (SABR into the treatment regimen. Here, we describe our initial experience in combining definitive upfront SABR to the primary lesion with chemo-radiation delivered with conventionally fractionated IG-IMRT to the remaining regional disease; along with clinical outcome following chemo-radiation with conventionally fractionated IG-IMRT alone in the treatment of locally advanced NSCLC.The clinical outcome of 29 patients with locally advanced NSCLC who underwent conventionally fractionated IG-IMRT, or definitive upfront SABR followed by IG-IMRT combined with chemotherapy (induction, concurrent, or both was retrospectively reviewed.After a median follow up of 23.7 months, the median overall survival (OS and progression-free survival (PFS were 19.8 and 11.3 months, respectively. The 2 year local, regional, and distant control was 60%, 62%, and 38%, respectively. No local failure was observed in 3 patients following SABR + IG-IMRT while 6/26 patients failed locally following IG-IMRT alone. SABR + IG-IMRT was well tolerated. No ≥ grade 3 radiation-related toxicity was observed.Definitive upfront SABR followed by IG-IMRT in selected patients with locally advanced NSCLC warrants further investigation in future clinical trials, while chemo-radiation with IG-IMRT alone was well tolerated.

  19. Tumor Volume-Adapted Dosing in Stereotactic Ablative Radiotherapy of Lung Tumors

    International Nuclear Information System (INIS)

    Trakul, Nicholas; Chang, Christine N.; Harris, Jeremy; Chapman, Christopher; Rao, Aarti; Shen, John; Quinlan-Davidson, Sean; Filion, Edith J.; Wakelee, Heather A.; Colevas, A. Dimitrios; Whyte, Richard I.

    2012-01-01

    Purpose: Current stereotactic ablative radiotherapy (SABR) protocols for lung tumors prescribe a uniform dose regimen irrespective of tumor size. We report the outcomes of a lung tumor volume-adapted SABR dosing strategy. Methods and Materials: We retrospectively reviewed the outcomes in 111 patients with a total of 138 primary or metastatic lung tumors treated by SABR, including local control, regional control, distant metastasis, overall survival, and treatment toxicity. We also performed subset analysis on 83 patients with 97 tumors treated with a volume-adapted dosing strategy in which small tumors (gross tumor volume <12 mL) received single-fraction regimens with biologically effective doses (BED) <100 Gy (total dose, 18–25 Gy) (Group 1), and larger tumors (gross tumor volume ≥12 mL) received multifraction regimens with BED ≥100 Gy (total dose, 50–60 Gy in three to four fractions) (Group 2). Results: The median follow-up time was 13.5 months. Local control for Groups 1 and 2 was 91.4% and 92.5%, respectively (p = 0.24) at 12 months. For primary lung tumors only (excluding metastases), local control was 92.6% and 91.7%, respectively (p = 0.58). Regional control, freedom from distant metastasis, and overall survival did not differ significantly between Groups 1 and 2. Rates of radiation pneumonitis, chest wall toxicity, and esophagitis were low in both groups, but all Grade 3 toxicities developed in Group 2 (p = 0.02). Conclusion: A volume-adapted dosing approach for SABR of lung tumors seems to provide excellent local control for both small- and large-volume tumors and may reduce toxicity.

  20. Synchrony - Cyberknife Respiratory Compensation Technology

    International Nuclear Information System (INIS)

    Ozhasoglu, Cihat; Saw, Cheng B.; Chen Hungcheng; Burton, Steven; Komanduri, Krishna; Yue, Ning J.; Huq, Saiful M.; Heron, Dwight E.

    2008-01-01

    Studies of organs in the thorax and abdomen have shown that these organs can move as much as 40 mm due to respiratory motion. Without compensation for this motion during the course of external beam radiation therapy, the dose coverage to target may be compromised. On the other hand, if compensation of this motion is by expansion of the margin around the target, a significant volume of normal tissue may be unnecessarily irradiated. In hypofractionated regimens, the issue of respiratory compensation becomes an important factor and is critical in single-fraction extracranial radiosurgery applications. CyberKnife is an image-guided radiosurgery system that consists of a 6-MV LINAC mounted to a robotic arm coupled through a control loop to a digital diagnostic x-ray imaging system. The robotic arm can point the beam anywhere in space with 6 degrees of freedom, without being constrained to a conventional isocenter. The CyberKnife has been recently upgraded with a real-time respiratory tracking and compensation system called Synchrony. Using external markers in conjunction with diagnostic x-ray images, Synchrony helps guide the robotic arm to move the radiation beam in real time such that the beam always remains aligned with the target. With the aid of Synchrony, the tumor motion can be tracked in three-dimensional space, and the motion-induced dosimetric change to target can be minimized with a limited margin. The working principles, advantages, limitations, and our clinical experience with this new technology will be discussed

  1. Outcomes of Risk-Adapted Fractionated Stereotactic Radiotherapy for Stage I Non-Small-Cell Lung Cancer

    International Nuclear Information System (INIS)

    Lagerwaard, Frank J.; Haasbeek, Cornelis J.A.; Smit, Egbert F.; Slotman, Ben J.; Senan, S.

    2008-01-01

    Purpose: High local control rates can be achieved using stereotactic radiotherapy in Stage I non-small-cell lung cancer (NSCLC), but reports have suggested that toxicity may be of concern. We evaluated early clinical outcomes of 'risk-adapted' fractionation schemes in patients treated in a single institution. Methods and Materials: Of 206 patients with Stage I NSCLC, 81% were unfit to undergo surgery and the rest refused surgery. Pathologic confirmation of malignancy was obtained in 31% of patients. All other patients had new or growing 18F-fluorodeoxyglucose positron emission tomography positive lesions with radiologic characteristics of malignancy. Planning four-dimensional computed tomography scans were performed and fractionation schemes used (3 x 20 Gy, 5 x 12 Gy, and 8 x 7.5 Gy) were determined by T stage and risk of normal tissue toxicity. Results: Median overall survival was 34 months, with 1- and 2-year survivals of 81% and 64%, respectively. Disease-free survival (DFS) at 1 and 2 years was 83% and 68%, respectively, and DFS correlated with T stage (p = 0.002). Local failure was observed in 7 patients (3%). The crude regional failure rate was 9%; isolated regional recurrence was observed in 4%. The distant progression-free survival at 1 and 2 years was 85% and 77%, respectively. SRT was well tolerated and severe late toxicity was observed in less than 3% of patients. Conclusions: SRT is well tolerated in patients with extensive comorbidity with high local control rates and minimal toxicity. Early outcomes are not inferior to those reported for conventional radiotherapy. In view of patient convenience, such risk-adapted SRT schedules should be considered treatment of choice in patients presenting with medically inoperable Stage I NSCLC

  2. Normal liver tissue sparing by intensity-modulated proton stereotactic body radiotherapy for solitary liver tumours

    International Nuclear Information System (INIS)

    Petersen, Joergen B. B.; Hansen, Anders T.; Lassen, Yasmin; Grau, Cai; Hoeyer, Morten; Muren, Ludvig P.

    2011-01-01

    Background. Stereotactic body radiotherapy (SBRT) is often the preferred treatment for the advanced liver tumours which owing to tumour distribution, size and multi-focality are out of range of surgical resection or radiofrequency ablation. However, only a minority of patients with liver tumours may be candidates for conventional SBRT because of the limited radiation tolerance of normal liver, intestine and other normal tissues. Due to the favourable depth-dose characteristics of protons, intensity-modulated proton therapy (IMPT) may be a superior alternative to photon-based SBRT. The purpose of this treatment planning study was therefore to investigate the potential sparing of normal liver by IMPT compared to photon-based intensity-modulated radiotherapy (IMRT) for solitary liver tumours. Material and methods. Ten patients with solitary liver metastasis treated at our institution with multi-field SBRT were retrospectively re-planned with IMRT and proton pencil beam scanning techniques. For the proton plans, two to three coplanar fields were used in contrast to five to six coplanar and non-coplanar photon fields. The same planning objectives were used for both techniques. A risk adapted dose prescription to the PTV surface of 12.5-16.75 Gy x 3 was used. Results. The spared liver volume for IMPT was higher compared to IMRT in all 10 patients. At the highest prescription dose level, the median liver volume receiving less than 15 Gy was 1411 cm 3 for IMPT and 955 cm 3 for IMRT (p D 15 Gy > 700 cm 3 constraint. For the D mean = 15 Gy constraint, nine of 10 cases could be treated at the highest dose level using IMPT whereas with IMRT, only two cases met this constraint at the highest dose level and six at the lowest dose level. Conclusion. A considerable sparing of normal liver tissue can be obtained using proton-based SBRT for solitary liver tumours

  3. Accuracy of image guidance using free-breathing cone-beam computed tomography for stereotactic lung radiotherapy.

    Science.gov (United States)

    Kamomae, Takeshi; Monzen, Hajime; Nakayama, Shinichi; Mizote, Rika; Oonishi, Yuuichi; Kaneshige, Soichiro; Sakamoto, Takashi

    2015-01-01

    Movement of the target object during cone-beam computed tomography (CBCT) leads to motion blurring artifacts. The accuracy of manual image matching in image-guided radiotherapy depends on the image quality. We aimed to assess the accuracy of target position localization using free-breathing CBCT during stereotactic lung radiotherapy. The Vero4DRT linear accelerator device was used for the examinations. Reference point discrepancies between the MV X-ray beam and the CBCT system were calculated using a phantom device with a centrally mounted steel ball. The precision of manual image matching between the CBCT and the averaged intensity (AI) images restructured from four-dimensional CT (4DCT) was estimated with a respiratory motion phantom, as determined in evaluations by five independent operators. Reference point discrepancies between the MV X-ray beam and the CBCT image-guidance systems, categorized as left-right (LR), anterior-posterior (AP), and superior-inferior (SI), were 0.33 ± 0.09, 0.16 ± 0.07, and 0.05 ± 0.04 mm, respectively. The LR, AP, and SI values for residual errors from manual image matching were -0.03 ± 0.22, 0.07 ± 0.25, and -0.79 ± 0.68 mm, respectively. The accuracy of target position localization using the Vero4DRT system in our center was 1.07 ± 1.23 mm (2 SD). This study experimentally demonstrated the sufficient level of geometric accuracy using the free-breathing CBCT and the image-guidance system mounted on the Vero4DRT. However, the inter-observer variation and systematic localization error of image matching substantially affected the overall geometric accuracy. Therefore, when using the free-breathing CBCT images, careful consideration of image matching is especially important.

  4. Patient-reported quality of life progression in men with prostate cancer following primary cryotherapy, cyberknife, or active holistic surveillance.

    Science.gov (United States)

    Werneburg, Glenn T; Kongnyuy, Michael; Halpern, Daniel M; Salcedo, Jose M; Kosinski, Kaitlin E; Haas, Jonathan A; Schiff, Jeffrey T; Corcoran, Anthony T; Katz, Aaron E

    2017-12-07

    Technological advancements have led to the success of minimally invasive treatment modalities for prostate cancer such as CyberKnife and Cryotherapy. Here, we investigate patient-reported urinary function, bowel habits, and sexual function in patients following CyberKnife (CK) or Cryotherapy treatment, and compare them with active holistic surveillance (AHS) patients. An IRB-approved institutional database was retrospectively reviewed for patients who underwent CK, Cryotherapy, or AHS. Quality of life (QoL) survey responses were collected every three months and the mean function scores were analyzed in yearly intervals over the 4 years post-treatment. 279 patients (767 survey sets) were included in the study. There was no difference among groups in urinary function scores. The CyberKnife group had significantly lower bowel habit scores in the early years following treatment (year 2 mean difference: -5.4, P treatment. A history of hormonal therapy was associated with a lower sexual function scores relative to those patients who did not receive hormones in both CyberKnife (-18.45, P < 0.01) and Cryotherapy patients (-14.6, P < 0.05). After initial lower bowel habits and sexual function scores, CyberKnife or Cryotherapy-treated patients had no significant difference in QoL relative to AHS patients. These results highlight the benefit of CyberKnife and Cryotherapy in the management of organ-confined prostate cancer.

  5. SU-F-T-620: Development of a Convolution/Superposition Dose Engine for CyberKnife System

    Energy Technology Data Exchange (ETDEWEB)

    Li, Y; Liu, B; Liang, B; Xu, X; Guo, B; Wei, R; Zhou, F [Beihang University, Beijing, Beijing (China); Song, T [Southern Medical University, Guangzhou, Guangdong (China); Xu, S [PLA General Hospital, Beijing, Beijing (China); Piao, J [302 Military Hospital, Beijing, Beijing (China)

    2016-06-15

    Purpose: Current CyberKnife treatment planning system (TPS) provided two dose calculation algorithms: Ray-tracing and Monte Carlo. Ray-tracing algorithm is fast, but less accurate, and also can’t handle irregular fields since a multi-leaf collimator system was recently introduced to CyberKnife M6 system. Monte Carlo method has well-known accuracy, but the current version still takes a long time to finish dose calculations. The purpose of this paper is to develop a GPU-based fast C/S dose engine for CyberKnife system to achieve both accuracy and efficiency. Methods: The TERMA distribution from a poly-energetic source was calculated based on beam’s eye view coordinate system, which is GPU friendly and has linear complexity. The dose distribution was then computed by inversely collecting the energy depositions from all TERMA points along 192 collapsed-cone directions. EGSnrc user code was used to pre-calculate energy deposition kernels (EDKs) for a series of mono-energy photons The energy spectrum was reconstructed based on measured tissue maximum ratio (TMR) curve, the TERMA averaged cumulative kernels was then calculated. Beam hardening parameters and intensity profiles were optimized based on measurement data from CyberKnife system. Results: The difference between measured and calculated TMR are less than 1% for all collimators except in the build-up regions. The calculated profiles also showed good agreements with the measured doses within 1% except in the penumbra regions. The developed C/S dose engine was also used to evaluate four clinical CyberKnife treatment plans, the results showed a better dose calculation accuracy than Ray-tracing algorithm compared with Monte Carlo method for heterogeneous cases. For the dose calculation time, it takes about several seconds for one beam depends on collimator size and dose calculation grids. Conclusion: A GPU-based C/S dose engine has been developed for CyberKnife system, which was proven to be efficient and accurate

  6. Impact of target reproducibility on tumor dose in stereotactic radiotherapy of targets in the lung and liver

    International Nuclear Information System (INIS)

    Wulf, Joern; Haedinger, Ulrich; Oppitz, Ulrich; Thiele, Wibke; Flentje, Michael

    2003-01-01

    Background and purpose: Previous analyses of target reproducibility in extracranial stereotactic radiotherapy have revealed standard security margins for planning target volume (PTV) definition of 5 mm in axial and 5-10 mm in longitudinal direction. In this study the reproducibility of the clinical target volume (CTV) of lung and liver tumors within the PTV over the complete course of hypofractionated treatment is evaluated. The impact of target mobility on dose to the CTV is assessed by dose-volume histograms (DVH). Materials and methods: Twenty-two pulmonary and 21 hepatic targets were treated with three stereotactic fractions of 10 Gy to the PTV-enclosing 100%-isodose with normalization to 150% at the isocenter. A conformal dose distribution was related to the PTV, which was defined by margins of 5-10 mm added to the CTV. Prior to each fraction a computed tomography (CT)-simulation over the complete target volume was performed resulting in a total of 60 CT-simulations for lung and 58 CT-simulations for hepatic targets. The CTV from each CT-simulation was segmented and matched with the CT-study used for treatment planning. A DVH of the simulated CTV was calculated for each fraction. The target coverage (TC) of dose to the simulated CTV was defined as the proportion of the CTV receiving at least the reference dose (100%). Results: A decrease of TC to 3 . Conclusions: Target reproducibility was precise within the reference isodose in 91% of lung and 81% of liver tumors with a TC of the complete CTV ≥95% at each fraction of treatment. Pulmonary targets with increased breathing mobility and liver tumors >100 cm 3 are at risk for target deviation exceeding the standard security margins for PTV-definition at least for one fraction and require individual evaluation of sufficient margins

  7. Stereotactic radiosurgery with an upper partial denture

    International Nuclear Information System (INIS)

    Tayama, Shusaku; Kunieda, Etsuo; Takeda, Atsushi; Takeda, Toshiaki; Oku, Yohei

    2009-01-01

    A 54-year-old male with partial denture underwent stereotactic radiosurgery with an infrared camera-guided system for a metastatic brain tumor arising from lung cancer. Although this method utilizes a biteplate mounted on the upper jaw to detect head movement, the patient only had four teeth in his upper jaw. In order to stabilize the biteplate, the maxillary denture was fixed to the biteplate with an autopolymerizing resin. In addition, the rest-occlusal position of the lower jaw was impressed on the inferior surface of the biteplate with an autopolymerizing resin. To assess reproducibility and stability, the distance between the left and right incus and left and right markers was measured during pre-planning, as well as before and after stereotactic irradiation. Wearing the biteplate ensures the accuracy of radiotherapy planning for the implementation of radiosurgery in patients who have many maxillary teeth missing. However, a large degree of error was observed when the biteplate was removed. (author)

  8. SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

    Energy Technology Data Exchange (ETDEWEB)

    Sheth, N; Tabibian, A; Rose, J; Alvelo, M; Perel, C; Laiken, K; Kim, A [Bayonne Medical Center, Bayonne, NJ (United States)

    2016-06-15

    Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

  9. SU-F-T-604: Dosimetric Evaluation of Intracranial Stereotactic Radiotherapy Plans On a LINAC

    International Nuclear Information System (INIS)

    Sheth, N; Tabibian, A; Rose, J; Alvelo, M; Perel, C; Laiken, K; Kim, A

    2016-01-01

    Purpose: To evaluate the dosimetry of cranial stereotactic radiotherapy (SRT) plans of varying techniques on linac that meets appropriate TG-142 tolerances using 1 cm leaf width multileaf collimator (MLC). Methods: Seventeen spherical targets were generated in the center of a head phantom with diameters ranging 8 mm to 40 mm. SRT plans used 100° non-coplanar arcs and 5 couch angles with 35° spacing. The field size was target plus 1 mm margin. Four plans were created for each target: symmetrical jaws blocking for 5 arcs with 0° collimator (J1C), symmetrical jaws blocking with 5 clockwise arcs with 0° collimator and 5 counter-clockwise arcs with 45° collimator (J2C), MLC blocking for 5 dynamic conformal arcs with 0° collimator (M1C), and MLC blocking for 5 clockwise dynamic conformal arcs with 0° collimators and 5 counter-clockwise dynamic conformal arcs with 45° collimator (M2C).Conformity was evaluated using a ratio of Rx to target volume (PITV). Heterogeneity was determined using a ratio of maximum dose to Rx dose. Falloff was scored using CGIg: difference of effective radii of spheres equal to half and full Rx volumes. Results: All plans met RTOG SRS criteria for conformity and heterogeneity. The mean PITV was 1.52±0.07, 1.49±0.08, 1.39±0.05, and 1.37±0.04 for J1C, J2C, M1C, and M2C plans respectively. The mean CGIg was 75.35±15.79, 74.19±16.66, 77.14±15.12, and 76.28±15.78 for J1C, J2C, M1C, and M2C plans respectively. The mean MDPD was 1.25±0.00 for all techniques. Conclusion: Clinically acceptable SRT plans for spherical targets were created on a linac with 1 cm MLC. Adding two collimator angles and MLC to arcs each improved conformity. The MLC improved the dose falloff while two collimator angles degraded it. This technique can expand the availability of SRT to patients especially to those who cannot travel to a facility with a dedicated stereotactic radiosurgery machine.

  10. Stereotactic radiotherapy of the prostate: fractionation and utilization in the United States

    International Nuclear Information System (INIS)

    Weiner, Josph P.; Schwartz, David; Shao, Meng; Osborn, Virginia; Schreiber, David; Choi, Kwang

    2017-01-01

    To analyze the utilization and fractionation of extreme hypofractionation via stereotactic body radiotherapy (SBRT) in the treatment of prostate cancer. Data was analyzed on men diagnosed with localized prostate cancer between 2004–2012 and treated with definitive-intent radiation therapy, as captured in the National Cancer Database. This database is a hospital-based registry that collects an estimated 70% of all diagnosed malignancies in the United States. There were 299,186 patients identified, of which 4,962 (1.7%) were identified as receiving SBRT as primary treatment. Of those men, 2,082 had low risk disease (42.0%), 2,201 had intermediate risk disease (44.4%), and 679 had high risk disease (13.7%). The relative utilization of SBRT increased from 0.1% in 2004 to 4.0% in 2012. Initially SBRT was more commonly used in academic programs, though as time progressed there was a shift to favor an increased absolute number of men treated in the community setting. Delivery of five separate treatments was the most commonly utilized fractionation pattern, with 4,635 patients (91.3%) receiving this number of treatments. The most common dosing pattern was 725 cGy × 5 fractions (49.6%) followed by 700 cGy × 5 fractions (21.3%). Extreme hypofractionation via SBRT is slowly increasing acceptance. Currently 700-725 cGy × 5 fractions appears to be the most commonly employed scheme. As further long-term data regarding the safety and efficacy emerges, the relative utilization of this modality is expected to continue to increase

  11. Stereotactic radiotherapy of the prostate: fractionation and utilization in the United States

    Energy Technology Data Exchange (ETDEWEB)

    Weiner, Josph P.; Schwartz, David; Shao, Meng; Osborn, Virginia; Schreiber, David [Dept. of Radiation Oncology, Veterans Affairs New York Harbor Healthcare System, Brooklyn (United States); Choi, Kwang [Dept. of Radiation Oncology, SUNY Downstate Medical Center, Brooklyn (United States)

    2017-06-15

    To analyze the utilization and fractionation of extreme hypofractionation via stereotactic body radiotherapy (SBRT) in the treatment of prostate cancer. Data was analyzed on men diagnosed with localized prostate cancer between 2004–2012 and treated with definitive-intent radiation therapy, as captured in the National Cancer Database. This database is a hospital-based registry that collects an estimated 70% of all diagnosed malignancies in the United States. There were 299,186 patients identified, of which 4,962 (1.7%) were identified as receiving SBRT as primary treatment. Of those men, 2,082 had low risk disease (42.0%), 2,201 had intermediate risk disease (44.4%), and 679 had high risk disease (13.7%). The relative utilization of SBRT increased from 0.1% in 2004 to 4.0% in 2012. Initially SBRT was more commonly used in academic programs, though as time progressed there was a shift to favor an increased absolute number of men treated in the community setting. Delivery of five separate treatments was the most commonly utilized fractionation pattern, with 4,635 patients (91.3%) receiving this number of treatments. The most common dosing pattern was 725 cGy × 5 fractions (49.6%) followed by 700 cGy × 5 fractions (21.3%). Extreme hypofractionation via SBRT is slowly increasing acceptance. Currently 700-725 cGy × 5 fractions appears to be the most commonly employed scheme. As further long-term data regarding the safety and efficacy emerges, the relative utilization of this modality is expected to continue to increase.

  12. TH-AB-201-01: A Feasibility Study of Independent Dose Verification for CyberKnife

    International Nuclear Information System (INIS)

    Sato, A; Noda, T; Keduka, Y; Kawajiri, T; Itano, M; Yamazaki, T; Tachibana, H

    2016-01-01

    Purpose: CyberKnife irradiation is composed of tiny-size, multiple and intensity-modulated beams compared to conventional linacs. Few of the publications for Independent dose calculation verification for CyberKnife have been reported. In this study, we evaluated the feasibility of independent dose verification for CyberKnife treatment as Secondary check. Methods: The followings were measured: test plans using some static and single beams, clinical plans in a phantom and using patient’s CT. 75 patient plans were collected from several treatment sites of brain, lung, liver and bone. In the test plans and the phantom plans, a pinpoint ion-chamber measurement was performed to assess dose deviation for a treatment planning system (TPS) and an independent verification program of Simple MU Analysis (SMU). In the clinical plans, dose deviation between the SMU and the TPS was performed. Results: In test plan, the dose deviations were 3.3±4.5%, and 4.1±4.4% for the TPS and the SMU, respectively. In the phantom measurements for the clinical plans, the dose deviations were −0.2±3.6% for the TPS and −2.3±4.8% for the SMU. In the clinical plans using the patient’s CT, the dose deviations were −3.0±2.1% (Mean±1SD). The systematic difference was partially derived from inverse square law and penumbra calculation. Conclusion: The independent dose calculation for CyberKnife shows −3.0±4.2% (Mean±2SD) and our study, the confidence limit was achieved within 5% of the tolerance level from AAPM task group 114 for non-IMRT treatment. Thus, it may be feasible to use independent dose calculation verification for CyberKnife treatment as the secondary check. This research is partially supported by Japan Agency for Medical Research and Development (AMED)

  13. Analysis of the impact of chest wall constraints on eligibility for a randomized trial of stereotactic body radiotherapy of peripheral stage 1 non-small cell lung cancer

    International Nuclear Information System (INIS)

    Siva, Shankar; Shaw, Mark; Gill, Suki; David, Ball; Chesson, Brent

    2012-01-01

    Chest wall toxicities are recognized complications of stereotactic radiotherapy (SBRT) in non-small cell lung cancer. To minimize toxicity, the Trans-Tasman Radiation Oncology Group (TROG) 09.02 ‘CHISEL’ study protocol excluded patients with tumours within 1cm of the chest wall. The purpose of this study is to evaluate the implication of chest wall proximity constraints on patient eligibility, toxicity and potential accrual. Exclusion zones of 1cm beyond the mediastinum and 2cm beyond the bifurcation of the lobar bronchi were incorporated into the CHISEL credentialing CT dataset. Volumes of lung within which tumours varying from 1cm to 5cm in diameter may occupy and remain eligible for the CHISEL study were calculated. These volumes were compared to a hypothetical model in which the 1cm chest wall proximity restriction was removed. The percentage of lung area in which a tumour mass can occupy and be suitable for CHISEL in the left and right lung were 54% and 60% respectively. Removing the constraint increased the percentage of available lung to 83% and 87% respectively. Considering a 2cm spherical tumour, only 21% and 31% of tumours in the left and right lung would be eligible with the chest wall constraint, whilst 39% and 50% respectively would be eligible without the constraint. The exclusion of tumours less than 1cm to chest wall significantly reduces the proportion of patients eligible for the CHISEL protocol. A review of the literature pertaining to chest wall toxicity after stereotactic radiotherapy supports a change in chest wall exclusion criteria for the CHISEL study.

  14. Acute exacerbation of subclinical idiopathic pulmonary fibrosis triggered by hypofractionated stereotactic body radiotherapy in a patient with primary lung cancer and slightly focal honeycombing

    International Nuclear Information System (INIS)

    Takeda, Atsuya; Sanuki, Naoko; Enomoto, Tatsuji; Takeda, Toshiaki; Kunieda, Etsuo; Nakajima, Takeshi; Sayama, Koichi

    2008-01-01

    Hypofractionated stereotactic body radiotherapy (SBRT) for pulmonary lesions provides a high local control rate, allows completely painless ambulatory treatment, and is not associated with adverse reactions in most cases. Here we report a 70-year-old lung cancer patient with slight focal pulmonary honeycombing in whom subclinical idiopathic pulmonary fibrosis was exacerbated by SBRT. This experience has important implications for the development of selection criteria prior to SBRT for pulmonary lesions. For SBRT candidates with lung tumors, attention must be paid to the presence of co-morbid interstitial pneumonia even if findings are minimal. Such patients must be informed of potential risks, and careful decision-making must take place when SBRT is being considered. (author)

  15. Emotional state of patients in radiotherapy and how they deal with their disorder

    Energy Technology Data Exchange (ETDEWEB)

    Voigtmann, Kristina [Dept. of Psychosomatics and Psychotherapy, Univ. Hospital Carl Gustav Carus, Technical Univ. of Dresden (Germany); Neurology Dept., Hospital and Clinic for Internal Medicine, NAEL - Norra Aelvsborg Laenssjukhus, Trollhaettan (Sweden); Koellner, Volker [Dept. of Psychoanalysis, Psychotherapy, and Psychosomatic Medicine, Saarland Univ. Hospital, Homburg/Saar (Germany); Dept. of Psychosomatic Medicine, Mediclin Bliestal Clinic, Blieskastel (Germany); Einsle, Franziska; Joraschky, Peter [Dept. of Psychosomatics and Psychotherapy, Univ. Hospital Carl Gustav Carus, Technical Univ. of Dresden (Germany); Alheit, Horst; Herrmann, Thomas [Dept. of Radiotherapy and Radiation Oncology, Univ. Hospital Carl Gustav Carus, Technical Univ. of Dresden (Germany)

    2010-04-15

    Purpose: The aim of the study was to record patients' symptoms of anxiety, depression and post-traumatic stress, as well as their subjective experience of illness, with different forms of radiotherapy and for different indications. The question is to be answered of whether more invasive techniques such as stereotactic radiotherapy involve greater stress or whether the psychological stress instead tends to be caused by the underlying disorder itself. Patients and methods: Questionnaires were given to 240 patients after conventional radiotherapy for a malignant underlying disorder, to 80 with a benign disorder, and to 67 patients following stereotactic radiotherapy. The German version of the Hospital Anxiety and Depression Scale (HADS-D) was used to measure anxiety and depression; the Post-Traumatic Symptom Scale (PTSS-10) was used to measure symptoms related to post-traumatic stress disorder (PTSD), and there were questions about patients' subjective experience of radiotherapy. Results: 28% of all patients scored in the pathologic or borderline anxiety range; 26% were in the pathologic or borderline depression range. 22% of patients were above the diagnostic cutoff for the PTSS-10. No differences were evident between the three groups in terms of anxiety and stress-related symptoms. Women were significantly (p = 0.001) more severely affected by symptoms of PTSD and anxiety than men. No gender differences could be proven in terms of depression. In the HADS-D, patients with a benign underlying disorder had significantly (p < 0.05) lower depression values than the two other groups studied. Conclusion: Patients who had undergone stereotactic radiotherapy did not demonstrate higher values for anxiety, depression or PTS symptoms than patients treated with conventional radiotherapy. From the results submitted here it cannot be assumed that this form of treatment leads to an increased incidence of traumatic stress or even post-traumatic stress disorder (PTSD). All

  16. Emotional state of patients in radiotherapy and how they deal with their disorder

    International Nuclear Information System (INIS)

    Voigtmann, Kristina; Koellner, Volker; Einsle, Franziska; Joraschky, Peter; Alheit, Horst; Herrmann, Thomas

    2010-01-01

    Purpose: The aim of the study was to record patients' symptoms of anxiety, depression and post-traumatic stress, as well as their subjective experience of illness, with different forms of radiotherapy and for different indications. The question is to be answered of whether more invasive techniques such as stereotactic radiotherapy involve greater stress or whether the psychological stress instead tends to be caused by the underlying disorder itself. Patients and methods: Questionnaires were given to 240 patients after conventional radiotherapy for a malignant underlying disorder, to 80 with a benign disorder, and to 67 patients following stereotactic radiotherapy. The German version of the Hospital Anxiety and Depression Scale (HADS-D) was used to measure anxiety and depression; the Post-Traumatic Symptom Scale (PTSS-10) was used to measure symptoms related to post-traumatic stress disorder (PTSD), and there were questions about patients' subjective experience of radiotherapy. Results: 28% of all patients scored in the pathologic or borderline anxiety range; 26% were in the pathologic or borderline depression range. 22% of patients were above the diagnostic cutoff for the PTSS-10. No differences were evident between the three groups in terms of anxiety and stress-related symptoms. Women were significantly (p = 0.001) more severely affected by symptoms of PTSD and anxiety than men. No gender differences could be proven in terms of depression. In the HADS-D, patients with a benign underlying disorder had significantly (p < 0.05) lower depression values than the two other groups studied. Conclusion: Patients who had undergone stereotactic radiotherapy did not demonstrate higher values for anxiety, depression or PTS symptoms than patients treated with conventional radiotherapy. From the results submitted here it cannot be assumed that this form of treatment leads to an increased incidence of traumatic stress or even post-traumatic stress disorder (PTSD). All in all, it

  17. Outcomes following definitive stereotactic body radiotherapy for patients with Child-Pugh B or C hepatocellular carcinoma

    International Nuclear Information System (INIS)

    Culleton, Shaelyn; Jiang, Haiyan; Haddad, Carol R.; Kim, John; Brierley, Jim; Brade, Anthony; Ringash, Jolie; Dawson, Laura A.

    2014-01-01

    Purpose: To report outcomes in patients with Child-Pugh B or C (CP B/C) hepatocellular carcinoma (HCC) treated with stereotactic body radiotherapy (SBRT). Methods and materials: A prospective study of SBRT was developed for patients with CP B7 or B8 unresectable HCC, <10 cm. Selected ineligible patients (e.g. CP > B8, >10 cm) treated off-study from 2004 to July 2012 were also reviewed. Patients were excluded if they were treated as a bridge-to-liver-transplant. Results: 29 patients with CP B/C HCC were treated with SBRT (median dose 30 Gy in 6 fractions) from 2004 to December 2012. The majority had CP B7 liver function (69%) and portal vein tumor thrombosis (76%). The median survival was 7.9 months (95% CI: 2.8–15.1). Survival was significantly better in patients with CP = B7 and AFP ⩽ 4491 ng/mL. Of 16 evaluable patients, 63% had a decline in CP score by ⩾2 points at 3 months. Conclusion: SBRT is a treatment option for selected HCC patients with small HCCs and modestly impaired (CP B7) liver function

  18. Outcomes of Stereotactic Body Radiotherapy (SBRT) treatment of multiple synchronous and recurrent lung nodules

    International Nuclear Information System (INIS)

    Owen, Dawn; Olivier, Kenneth R; Mayo, Charles S; Miller, Robert C; Nelson, Kathryn; Bauer, Heather; Brown, Paul D; Park, Sean S; Ma, Daniel J; Garces, Yolanda I

    2015-01-01

    Stereotactic body radiotherapy (SBRT) is evolving into a standard of care for unresectable lung nodules. Local control has been shown to be in excess of 90% at 3 years. However, some patients present with synchronous lung nodules in the ipsilateral or contralateral lobe or metasynchronous disease. In these cases, patients may receive multiple courses of lung SBRT or a single course for synchronous nodules. The toxicity of such treatment is currently unknown. Between 2006 and 2012, 63 subjects with 128 metasynchronous and synchronous lung nodules were treated at the Mayo Clinic with SBRT. Demographic patient data and dosimetric data regarding SBRT treatments were collected. Acute toxicity (defined as toxicity < 90 days) and late toxicity (defined as toxicity > = 90 days) were reported and graded as per standardized CTCAE 4.0 criteria. Local control, progression free survival and overall survival were also described. The median age of patients treated was 73 years. Sixty five percent were primary or recurrent lung cancers with the remainder metastatic lung nodules of varying histologies. Of 63 patients, 18 had prior high dose external beam radiation to the mediastinum or chest. Dose and fractionation varied but the most common prescriptions were 48 Gy/4 fractions, 54 Gy/3 fractions, and 50 Gy/5 fractions. Only 6 patients demonstrated local recurrence. With a median follow up of 12.6 months, median SBRT specific overall survival and progression free survival were 35.7 months and 10.7 months respectively. Fifty one percent (32/63 patients) experienced acute toxicity, predominantly grade 1 and 2 fatigue. One patient developed acute grade 3 radiation pneumonitis at 75 days. Forty six percent (29/63 patients) developed late effects. Most were grade 1 dyspnea. There was one patient with grade 5 pneumonitis. Multiple courses of SBRT and SBRT delivery after external beam radiotherapy appear to be feasible and safe. Most toxicity was grade 1 and 2 but the risk was

  19. Quality level of a treatment by Cyberknife with Synchrony; Niveau de qualite d'un traitement par le CyberKnife avec Synchrony

    Energy Technology Data Exchange (ETDEWEB)

    Khawaja, M.S.A.; Noel, A. [CRAN UMR 7039, CNRS, 54 - Vandoeuvre-les-Nancy (France); Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Nancy-1 Univ., 54 (France); Marchesi, V. [Centre Alexis-Vautrin, 54 - Vandoeuvre-les-Nancy (France); Wolf, D. [INPL CRAN UMR 7039, CNRS, 54 - Vandoeuvre-les-Nancy (France)

    2009-10-15

    The Cyberknife and its Synchrony associated subsystem represent a very reliable mean to treat the tumors of soft tissues moving with respiration. It allows to guarantee a high quality of treatment because of sub-millimetric accuracy whatever be the complexity degree of the patient respiration cycle. (N.C.)

  20. Radiographic and metabolic response rates following image-guided stereotactic radiotherapy for lung tumors

    International Nuclear Information System (INIS)

    Mohammed, Nasiruddin; Grills, Inga S.; Wong, Ching-Yee Oliver; Galerani, Ana Paula; Chao, Kenneth; Welsh, Robert; Chmielewski, Gary; Yan Di; Kestin, Larry L.

    2011-01-01

    Purpose: To evaluate radiographic and metabolic response after stereotactic body radiotherapy (SBRT) for early lung tumors. Materials and methods: Thirty-nine tumors were treated prospectively with SBRT (dose = 48-60 Gy, 4-5 Fx). Thirty-six cases were primary NSCLC (T1N0 = 67%; T2N0 = 25%); three cases were solitary metastases. Patients were followed using CT and PET at 6, 16, and 52 weeks post-SBRT, with CT follow-up thereafter. RECIST and EORTC criteria were used to evaluate CT and PET responses. Results: At median follow-up of 9 months (0.4-26), RECIST complete response (CR), partial response (PR), and stable disease (SD) rates were 3%, 43%, 54% at 6 weeks; 15%, 38%, 46% at 16 weeks; 27%, 64%, 9% at 52 weeks. Mean baseline tumor volume was reduced by 46%, 70%, 87%, and 96%, respectively at 6, 16, 52, and 72 weeks. Mean baseline maximum standardized uptake value (SUV) was 8.3 (1.1-20.3) and reduced to 3.4, 3.0, and 3.7 at 6, 16, and 52 weeks after SBRT. EORTC metabolic CR/PR, SD, and progressive disease rates were 67%, 22%, 11% at 6 weeks; 86%, 10%, 3% at 16 weeks; 95%, 5%, 0% at 52 weeks. Conclusions: SBRT yields excellent RECIST and EORTC based response. Metabolic response is rapid however radiographic response occurs even after 1-year post treatment.

  1. Stereotactic radiotherapy using Novalis for skull base metastases developing with cranial nerve symptoms.

    Science.gov (United States)

    Mori, Yoshimasa; Hashizume, Chisa; Kobayashi, Tatsuya; Shibamoto, Yuta; Kosaki, Katsura; Nagai, Aiko

    2010-06-01

    Skull base metastases are challenging situations because they often involve critical structures such as cranial nerves. We evaluated the role of stereotactic radiotherapy (SRT) which can give high doses to the tumors sparing normal structures. We treated 11 cases of skull base metastases from other visceral carcinomas. They had neurological symptoms due to cranial nerve involvement including optic nerve (3 patients), oculomotor (3), trigeminal (6), abducens (1), facial (4), acoustic (1), and lower cranial nerves (1). The interval between the onset of cranial nerve symptoms and Novalis SRT was 1 week to 7 months. Eleven tumors of 8-112 ml in volume were treated by Novalis SRT with 30-50 Gy in 10-14 fractions. The tumors were covered by 90-95% isodose. Imaging and clinical follow-up has been obtained in all 11 patients for 5-36 months after SRT. Seven patients among 11 died from primary carcinoma or other visceral metastases 9-36 months after Novalis SRT. All 11 metastatic tumors were locally controlled until the end of the follow-up time or patient death, though retreatment for re-growth was done in 1 patient. In 10 of 11 patients, cranial nerve deficits were improved completely or partially. In some patients, the cranial nerve symptoms were relieved even during the period of fractionated SRT. Novalis SRT is thought to be safe and effective treatment for skull base metastases with involvement of cranial nerves and it may improve cranial nerve symptoms quickly.

  2. Dosimetric and patient correlates of quality of life after prostate stereotactic ablative radiotherapy

    International Nuclear Information System (INIS)

    Elias, Evelyn; Helou, Joelle; Zhang, Liying; Cheung, Patrick; Deabreu, Andrea; D’Alimonte, Laura; Sethukavalan, Perakaa; Mamedov, Alexandre; Cardoso, Marlene; Loblaw, Andrew

    2014-01-01

    Background and purpose: Initial results of Stereotactic Ablative Body Radiotherapy (SABR) in the treatment of localized prostate cancer appear promising however long-term quality of life (QOL) outcomes and dosimetric correlates are necessary. Material and methods: A phase I/II study was performed where low risk prostate cancer patients received SABR 35 Gy in 5 fractions, once weekly. Patient self-reported QOL was measured using the Expanded Prostate Cancer Index Composite (EPIC) at baseline and q6 month up to 5 years. Urinary, bowel and sexual domains were analyzed. A minimally clinical important change (MCIC) was defined as 0.5 ∗ standard deviation of the baseline. Univariate and multivariate logistic regression were used to identify dosimetric predictors of MCIC. Results: 84 patients were included. The median follow-up was 50.8 months (interquartile range [IQR], 44.7–56.3). 17.9%, 26.2% and 37.5% of patients reported worse QOL on follow up in the urinary, bowel and sexual domains respectively. On univariate analysis Rectal V31.8 > 10%, D1cc > 35 Gy were associated with bowel MCIC, penile bulb (PB) V35 > 4%, V20 > 40% with sexual MCIC. Of these factors only rectal D1cc and PB V35 were predictors of worse QOL on multivariate analysis. Conclusions: Long-term single-institution QOL outcomes are encouraging. Rigorous dosimetric constraints are needed to keep bothersome side effects low

  3. Real-time 3D-surface-guided head refixation useful for fractionated stereotactic radiotherapy

    International Nuclear Information System (INIS)

    Li Shidong; Liu Dezhi; Yin Gongjie; Zhuang Ping; Geng, Jason

    2006-01-01

    Accurate and precise head refixation in fractionated stereotactic radiotherapy has been achieved through alignment of real-time 3D-surface images with a reference surface image. The reference surface image is either a 3D optical surface image taken at simulation with the desired treatment position, or a CT/MRI-surface rendering in the treatment plan with corrections for patient motion during CT/MRI scans and partial volume effects. The real-time 3D surface images are rapidly captured by using a 3D video camera mounted on the ceiling of the treatment vault. Any facial expression such as mouth opening that affects surface shape and location can be avoided using a new facial monitoring technique. The image artifacts on the real-time surface can generally be removed by setting a threshold of jumps at the neighboring points while preserving detailed features of the surface of interest. Such a real-time surface image, registered in the treatment machine coordinate system, provides a reliable representation of the patient head position during the treatment. A fast automatic alignment between the real-time surface and the reference surface using a modified iterative-closest-point method leads to an efficient and robust surface-guided target refixation. Experimental and clinical results demonstrate the excellent efficacy of <2 min set-up time, the desired accuracy and precision of <1 mm in isocenter shifts, and <1 deg. in rotation

  4. Reliability of the Bony Anatomy in Image-Guided Stereotactic Radiotherapy of Brain Metastases

    International Nuclear Information System (INIS)

    Guckenberger, Matthias; Baier, Kurt; Guenther, Iris; Richter, Anne; Wilbert, Juergen; Sauer, Otto; Vordermark, Dirk; Flentje, Michael

    2007-01-01

    Purpose: To evaluate whether the position of brain metastases remains stable between planning and treatment in cranial stereotactic radiotherapy (SRT). Methods and Materials: Eighteen patients with 20 brain metastases were treated with single-fraction (17 lesions) or hypofractionated (3 lesions) image-guided SRT. Median time interval between planning and treatment was 8 days. Before treatment a cone-beam CT (CBCT) and a conventional CT after application of i.v. contrast were acquired. Setup errors using automatic bone registration (CBCT) and manual soft-tissue registration of the brain metastases (conventional CT) were compared. Results: Tumor size was not significantly different between planning and treatment. The three-dimensional setup error (mean ± SD) was 4.0 ± 2.1 mm and 3.5 ± 2.2 mm according to the bony anatomy and the lesion itself, respectively. A highly significant correlation between automatic bone match and soft-tissue registration was seen in all three directions (r ≥ 0.88). The three-dimensional distance between the isocenter according to bone match and soft-tissue registration was 1.7 ± 0.7 mm, maximum 2.8 mm. Treatment of intracranial pressure with steroids did not influence the position of the lesion relative to the bony anatomy. Conclusion: With a time interval of approximately 1 week between planning and treatment, the bony anatomy of the skull proved to be an excellent surrogate for the target position in image-guided SRT

  5. Comparison of dose evaluation index by pencil beam convolution and anisotropic analytical algorithm in stereotactic radiotherapy for lung cancer

    International Nuclear Information System (INIS)

    Tachibana, Masayuki; Noguchi, Yoshitaka; Fukunaga, Jyunichi; Hirano, Naomi; Yoshidome, Satoshi; Hirose, Takaaki

    2009-01-01

    We previously studied dose distributions of stereotactic radiotherapy (SRT) for lung cancer. Our aim is to compare in combination pencil beam convolution with the inhomogeneity correction algorithm of Batho power low [PBC (BPL)] to the anisotropic analytical algorithm (AAA) by using the dose evaluation indexes. There were significant differences in D95, planning target volume (PTV) mean dose, homogeneity index, and conformity index, V10, and V5. The dose distributions inside the PTV calculated by PBC (BPL) were more uniform than those of AAA. There were no significant differences in V20 and mean dose of total lung. There was no large difference for the whole lung. However, the surrounding high-dose region of PTV became smaller in AAA. The difference in dose evaluation indexes extended between PBC (BPL) and AAA that as many as low CT value of lung. When the dose calculation algorithm is changed, it is necessary to consider difference dose distributions compared with those of established practice. (author)

  6. Similar-Case-Based Optimization of Beam Arrangements in Stereotactic Body Radiotherapy for Assisting Treatment Planners

    Directory of Open Access Journals (Sweden)

    Taiki Magome

    2013-01-01

    Full Text Available Objective. To develop a similar-case-based optimization method for beam arrangements in lung stereotactic body radiotherapy (SBRT to assist treatment planners. Methods. First, cases that are similar to an objective case were automatically selected based on geometrical features related to a planning target volume (PTV location, PTV shape, lung size, and spinal cord position. Second, initial beam arrangements were determined by registration of similar cases with the objective case using a linear registration technique. Finally, beam directions of the objective case were locally optimized based on the cost function, which takes into account the radiation absorption in normal tissues and organs at risk. The proposed method was evaluated with 10 test cases and a treatment planning database including 81 cases, by using 11 planning evaluation indices such as tumor control probability and normal tissue complication probability (NTCP. Results. The procedure for the local optimization of beam arrangements improved the quality of treatment plans with significant differences (P<0.05 in the homogeneity index and conformity index for the PTV, V10, V20, mean dose, and NTCP for the lung. Conclusion. The proposed method could be usable as a computer-aided treatment planning tool for the determination of beam arrangements in SBRT.

  7. Stereotactic Body Radiotherapy for Metastatic Lung Cancer as Oligo-Recurrence: An Analysis of 42 Cases

    Directory of Open Access Journals (Sweden)

    Wataru Takahashi

    2012-01-01

    Full Text Available Purpose. To investigate the outcome and toxicity of stereotactic body radiotherapy (SBRT in patients with oligo-recurrence cancer in the lung (ORCL. Methods and Materials. A retrospective review of 42 patients with ORCL who underwent SBRT in our two hospitals was conducted. We evaluated the outcome and adverse effects after SBRT for ORCL. Results. All patients finished their SBRT course without interruptions of toxicity reasons. The median follow-up period was 20 months (range, 1–90 months. The 2-year local control rate and overall survival were 87% (95% CI, 75–99% and 65% (95% CI, 48–82%. As for prognostic factor, the OS of patients with a short disease-free interval (DFI months, between the initial therapy and SBRT for ORCL, was significantly worse than the OS of long DFI months (. The most commonly observed late effect was radiation pneumonitis. One patient had grade 4 gastrointestinal toxicity (perforation of gastric tube. No other ≧ grade 3 acute and late adverse events occurred. There were no treatment-related deaths during this study. Conclusions. In patients with ORCL, radical treatment with SBRT is safe and provides a chance for long-term survival by offering favorable local control.

  8. Postoperative re-irradiation using stereotactic body radiotherapy for metastatic epidural spinal cord compression.

    Science.gov (United States)

    Ito, Kei; Nihei, Keiji; Shimizuguchi, Takuya; Ogawa, Hiroaki; Furuya, Tomohisa; Sugita, Shurei; Hozumi, Takahiro; Keisuke Sasai; Karasawa, Katsuyuki

    2018-06-15

    OBJECTIVE This study aimed to clarify the outcomes of postoperative re-irradiation using stereotactic body radiotherapy (SBRT) for metastatic epidural spinal cord compression (MESCC) in the authors' institution and to identify factors correlated with local control. METHODS Cases in which patients with previously irradiated MESCC underwent decompression surgery followed by spine SBRT as re-irradiation between April 2013 and May 2017 were retrospectively reviewed. The surgical procedures were mainly performed by the posterior approach and included decompression and fixation. The prescribed dose for spine SBRT was 24 Gy in 2 fractions. The primary outcome was local control, which was defined as elimination, shrinkage, or no change of the tumor on CT or MRI obtained approximately every 3 months after SBRT. In addition, various patient-, treatment-, and tumor-specific factors were evaluated to determine their predictive value for local control. RESULTS Twenty-eight cases were identified in the authors' institutional databases as meeting the inclusion criteria. The histology of the primary disease was thyroid cancer in 7 cases, lung cancer in 6, renal cancer in 3, colorectal cancer in 3, and other cancers in 9. The most common previous radiation dose was 30 Gy in 10 fractions (15 cases). The mean interval since the most recent irradiation was 16 months (range 5-132 months). The median duration of follow-up after SBRT was 13 months (range 4-38 months). The 1-year local control rate was 70%. In the analysis of factors related to local control, Bilsky grade, number of vertebral levels in the treatment target, the interval between the latest radiotherapy and SBRT, recursive partitioning analysis (RPA), the prognostic index for spinal metastases (PRISM), and the revised Tokuhashi score were not significantly correlated with local control. The favorable group classified by the Rades prognostic score achieved a significantly higher 1-year local control rate than the unfavorable

  9. Stereotactic hypofractionated accurate radiotherapy of the prostate (SHARP), 33.5 Gy in five fractions for localized disease: First clinical trial results

    International Nuclear Information System (INIS)

    Madsen, Berit L.; Hsi, R. Alex; Pham, Huong T.; Fowler, Jack F.; Esagui, Laura C.; Corman, John

    2007-01-01

    Purpose: To evaluate the feasibility and toxicity of stereotactic hypofractionated accurate radiotherapy (SHARP) for localized prostate cancer. Methods and Materials: A Phase I/II trial of SHARP performed for localized prostate cancer using 33.5 Gy in 5 fractions, calculated to be biologically equivalent to 78 Gy in 2 Gy fractions (α/β ratio of 1.5 Gy). Noncoplanar conformal fields and daily stereotactic localization of implanted fiducials were used for treatment. Genitourinary (GU) and gastrointestinal (GI) toxicity were evaluated by American Urologic Association (AUA) score and Common Toxicity Criteria (CTC). Prostate-specific antigen (PSA) values and self-reported sexual function were recorded at specified follow-up intervals. Results: The study includes 40 patients. The median follow-up is 41 months (range, 21-60 months). Acute toxicity Grade 1-2 was 48.5% (GU) and 39% (GI); 1 acute Grade 3 GU toxicity. Late Grade 1-2 toxicity was 45% (GU) and 37% (GI). No late Grade 3 or higher toxicity was reported. Twenty-six patients reported potency before therapy; 6 (23%) have developed impotence. Median time to PSA nadir was 18 months with the majority of nadirs less than 1.0 ng/mL. The actuarial 48-month biochemical freedom from relapse is 70% for the American Society for Therapeutic Radiology and Oncology definition and 90% by the alternative nadir + 2 ng/mL failure definition. Conclusions: SHARP for localized prostate cancer is feasible with minimal acute or late toxicity. Dose escalation should be possible

  10. Fractionated stereotactic radiotherapy boost for gynecologic tumors: An alternative to brachytherapy?

    International Nuclear Information System (INIS)

    Molla, Meritxell; Escude, Lluis D.; Nouet, Philippe; Popowski, Youri D.Sc.; Hidalgo, Alberto; Rouzaud, Michel; Linero, Dolores; Miralbell, Raymond

    2005-01-01

    Purpose: A brachytherapy (BT) boost to the vaginal vault is considered standard treatment for many endometrial or cervical cancers. We aimed to challenge this treatment standard by using stereotactic radiotherapy (SRT) with a linac-based micromultileaf collimator technique. Methods and Materials: Since January 2002, 16 patients with either endometrial (9) or cervical (7) cancer have been treated with a final boost to the areas at higher risk for relapse. In 14 patients, the target volume included the vaginal vault, the upper vagina, the parametria, or (if not operated) the uterus (clinical target volume [CTV]). In 2 patients with local relapse, the CTV was the tumor in the vaginal stump. Margins of 6-10 mm were added to the CTV to define the planning target volume (PTV). Hypofractionated dynamic-arc or intensity-modulated radiotherapy techniques were used. Postoperative treatment was delivered in 12 patients (2 x 7 Gy to the PTV with a 4-7-day interval between fractions). In the 4 nonoperated patients, a dose of 4 Gy/fraction in 5 fractions with 2 to 3 days' interval was delivered. Patients were immobilized in a customized vacuum body cast and optimally repositioned with an infrared-guided system developed for extracranial SRT. To further optimize daily repositioning and target immobilization, an inflated rectal balloon was used during each treatment fraction. In 10 patients, CT resimulation was performed before the last boost fraction to assess for repositioning reproducibility via CT-to-CT registration and to estimate PTV safety margins around the CTV. Finally, a comparative treatment planning study between BT and SRT was performed in 2 patients with an operated endometrial Stage I cancer. Results: No patient developed severe acute urinary or low-intestinal toxicity. No patient developed urinary late effects (>6 months). One patient with a vaginal relapse previously irradiated to the pelvic region presented with Grade 3 rectal bleeding 18 months after retreatment

  11. Intrafraction Variation of Mean Tumor Position During Image-Guided Hypofractionated Stereotactic Body Radiotherapy for Lung Cancer

    International Nuclear Information System (INIS)

    Shah, Chirag; Grills, Inga S.; Kestin, Larry L.; McGrath, Samuel; Ye Hong; Martin, Shannon K.; Yan Di

    2012-01-01

    Purpose: Prolonged delivery times during daily cone-beam computed tomography (CBCT)-guided lung stereotactic body radiotherapy (SBRT) introduce concerns regarding intrafraction variation (IFV) of the mean target position (MTP). The purpose of this study was to evaluate the magnitude of the IFV-MTP and to assess target margins required to compensate for IFV and postonline CBCT correction residuals. Patient, treatment, and tumor characteristics were analyzed with respect to their impact on IFV-MTP. Methods and Materials: A total of 126 patients with 140 tumors underwent 659 fractions of lung SBRT. Dose prescribed was 48 or 60 Gy in 12 Gy fractions. Translational target position correction of the MTP was performed via onboard CBCT. IFV-MTP was measured as the difference in MTP between the postcorrection CBCT and the posttreatment CBCT excluding residual error. Results: IFV-MTP was 0.2 ± 1.8 mm, 0.1 ± 1.9 mm, and 0.01 ± 1.5 mm in the craniocaudal, anteroposterior, and mediolateral dimensions and the IFV-MTP vector was 2.3 ± 2.1 mm. Treatment time and excursion were found to be significant predictors of IFV-MTP. An IFV-MTP vector greater than 2 and 5 mm was seen in 40.8% and 7.2% of fractions, respectively. IFV-MTP greater than 2 mm was seen in heavier patients with larger excursions and longer treatment times. Significant differences in IFV-MTP were seen between immobilization devices. The stereotactic frame immobilization device was found to be significantly less likely to have an IFV-MTP vector greater than 2 mm compared with the alpha cradle, BodyFIX, and hybrid immobilization devices. Conclusions: Treatment time and respiratory excursion are significantly associated with IFV-MTP. Significant differences in IFV-MTP were found between immobilization devices. Target margins for IFV-MTP plus post-correction residuals are dependent on immobilization device with 5-mm uniform margins being acceptable for the frame immobilization device.

  12. Pulmonary Function Testing After Stereotactic Body Radiotherapy to the Lung

    International Nuclear Information System (INIS)

    Bishawi, Muath; Kim, Bong; Moore, William H.; Bilfinger, Thomas V.

    2012-01-01

    Purpose: Surgical resection remains the standard of care for operable early-stage non–small-cell lung cancer (NSCLC). However, some patients are not fit for surgery because of comorbidites such as chronic obstructive pulmonary disease (COPD) and other medical conditions. We aimed to evaluate pulmonary function and tumor volume before and after stereotactic body radiotherapy (SBRT) for patients with and without COPD in early-stage lung cancer. Methods and Materials: A review of prospectively collected data of Stage I and II lung cancers, all treated with SBRT, was performed. The total SBRT treatment was 60 Gy administered in three 20 Gy fractions. The patients were analyzed based on their COPD status, using their pretreatment pulmonary function test cutoffs as established by the American Thoracic Society guidelines (forced expiratory volume [FEV]% ≤50% predicted, FEV%/forced vital capacity [FVC]% ≤70%). Changes in tumor volume were also assessed by computed tomography. Results: Of a total of 30 patients with Stage I and II lung cancer, there were 7 patients in the COPD group (4 men, 3 women), and 23 in t he No-COPD group (9 men, 14 women). At a mean follow-up time of 4 months, for the COPD and No-COPD patients, pretreatment and posttreatment FEV% was similar: 39 ± 5 vs. 40 ± 9 (p = 0.4) and 77 ± 0.5 vs. 73 ± 24 (p = 0.9), respectively. The diffusing capacity of the lungs for carbon monoxide (DL CO ) did significantly increase for the No-COPD group after SBRT treatment: 60 ± 24 vs. 69 ± 22 (p = 0.022); however, DL CO was unchanged for the COPD group: 49 ± 13 vs. 50 ± 14 (p = 0.8). Although pretreatment tumor volume was comparable for both groups, tumor volume significantly shrank in the No-COPD group from 19 ± 24 to 9 ± 16 (p 1 and FVC, but it shrank tumor volume and improved DL CO for patients without COPD.

  13. Cyberknife Stereotactic Body Radiation Therapy for Nonresectable Tumors of the Liver: Preliminary Results

    Directory of Open Access Journals (Sweden)

    K. Goyal

    2010-01-01

    Full Text Available Purpose. Stereotactic body radiation therapy (SBRT has emerged as a treatment option for local tumor control of primary and secondary malignancies of the liver. We report on our updated experience with SBRT in patients with non-resectable tumors of the liver. Methods. Our first 17 consecutive patients (mean age 58.1 years receiving SBRT for HCC (=6, IHC (=3, and LM (=8 are presented. Mean radiation dose was 34Gy delivered over 1–3 fractions. Results. Treated patients had a mean decrease in maximum pretreatment tumor diameter from 6.9±4.6 cm to 5.0±2.1 cm at three months after treatment (<.05. The mean total tumor volume reduction was 44% at six months (<.05. 82% of all patients (14/17 achieved local control with a median follow-up of 8 months. 100% of patients with HCC (=6 achieved local control. Patients with surgically placed fiducial markers had no complications related to marker placement. Conclusion. Our preliminary results showed that SBRT is a safe and effective local treatment modality in selected patients with liver malignancies with minimal adverse events. Further studies are needed to define its role in the management of these malignancies.

  14. EPID-based in vivo dosimetry for stereotactic body radiotherapy of non-small cell lung tumors: Initial clinical experience.

    Science.gov (United States)

    Consorti, R; Fidanzio, A; Brainovich, V; Mangiacotti, F; De Spirito, M; Mirri, M A; Petrucci, A

    2017-10-01

    EPID-based in vivo dosimetry (IVD) has been implemented for stereotactic body radiotherapy treatments of non-small cell lung cancer to check both isocenter dose and the treatment reproducibility comparing EPID portal images. 15 patients with lung tumors of small dimensions and treated with volumetric modulated arc therapy were enrolled for this initial experience. IVD tests supplied ratios R between in vivo reconstructed and planned isocenter doses. Moreover a γ-like analysis between daily EPID portal images and a reference one, in terms of percentage of points with γ-value smaller than 1, P γlevels of 5% for R ratio, P γlevel, and an average P γ90%. Paradigmatic discrepancies were observed in three patients: a set-up error and a patient morphological change were identified thanks to CBCT image analysis whereas the third discrepancy was not fully justified. This procedure can provide improved patient safety as well as a first step to integrate IVD and CBCT dose recalculation. Copyright © 2017 Associazione Italiana di Fisica Medica. Published by Elsevier Ltd. All rights reserved.

  15. Lung Density Changes After Stereotactic Radiotherapy: A Quantitative Analysis in 50 Patients

    Energy Technology Data Exchange (ETDEWEB)

    Palma, David A., E-mail: david.palma@uwo.ca [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Soernsen de Koste, John van; Verbakel, Wilko F.A.R. [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands); Vincent, Andrew [Department of Biometrics, Netherlands Cancer Institute, Amsterdam (Netherlands); Senan, Suresh [Department of Radiation Oncology, VU University Medical Center, Amsterdam (Netherlands)

    2011-11-15

    Purpose: Radiologic lung density changes are observed in more than 50% of patients after stereotactic body radiotherapy (SBRT) for lung cancer. We studied the relationship between SBRT dose and posttreatment computed tomography (CT) density changes, a surrogate for lung injury. Methods and Materials: The SBRT fractionation schemes used to treat Stage I lung cancer with RapidArc were three fractions of 18 Gy, five fractions of 11 Gy, or eight fractions of 7.5 Gy, prescribed at the 80% isodose. Follow-up CT scans performed at less than 6 months (n = 50) and between 6 and 9 months (n = 30) after SBRT were reviewed. Posttreatment scans were coregistered with baseline scans using a B-spline deformable registration algorithm. Voxel-Hounsfield unit histograms were created for doses between 0.5 and 50 Gy. Linear mixed effects models were used to assess the effects of SBRT dose on CT density, and the influence of possible confounders was tested. Results: Increased CT density was associated with higher dose, increasing planning target volume size, and increasing time after SBRT (all p < 0.0001). Density increases were apparent in areas receiving >6 Gy, were most prominent in areas receiving >20 Gy, and seemed to plateau above 40 Gy. In regions receiving >36 Gy, the reduction in air-filled fraction of lung after treatment was up to 18%. No increase in CT density was observed in the contralateral lung receiving {>=}3 Gy. Conclusions: A dose-response relationship exists for quantitative CT density changes after SBRT. A threshold of effect is seen at low doses, and a plateau at highest doses.

  16. Stereotactic body radiotherapy (sbrt) in lung oligometastatic patients: role of local treatments

    International Nuclear Information System (INIS)

    Navarria, Pierina; Tozzi, Angelo; Reggiori, Giacomo; Fogliata, Antonella; Scorsetti, Marta; Ascolese, Anna Maria; Tomatis, Stefano; Cozzi, Luca; De Rose, Fiorenza; Mancosu, Pietro; Alongi, Filippo; Clerici, Elena; Lobefalo, Francesca

    2014-01-01

    Data in the literature suggest the existence of oligometastatic disease, a state in which metastases are limited in number and site. Different kinds of local therapies have been used for the treatment of limited metastases and in the recent years reports on the use of Stereotactic Ablative radiotherapy (SABR) are emerging and the early results on local control are promising. From October 2010 to February 2012, 76 consecutive patients for 118 lung lesions were treated. SABR was performed in case of controlled primary tumor, long-term of progression disease, exclusion of surgery, and number of metastatic sites ≤ 5. Different kinds of primary tumors were treated, the most common were lung and colon-rectal cancer. The total dose prescribed varied according to tumor site and maximum diameter. Dose prescription was 48 Gy in 4 fractions for peripheral lesions, 60 Gy in 8 fractions for central lesions and 60 Gy in 3 fractions for peripheral lesions with diameter ≤ 2 cm. Dosimetric planning objectives were met for the cohort of patients with in particular V98% = 98.1 ± 3.4% for the CTV and mean lung dose of 3.7 ± 3.8 Gy. Radiological response was obtained in the vast majority of patients. The local control at 1, 2 and 3 years was 95%, 89% and 89% respectively. No major pulmonary toxicity, chest pain or rib fracture occurred. The median follow up was 20 months (range 6–45 months). Overall Survival (OS) at 1, 2 and 3 years was 84.1%, 73% and 73% respectively. SABR is feasible with limited morbidity and promising results in terms of local contro, survival and toxicity

  17. WE-H-BRC-03: Failure Mode and Effects Analysis in the First Clinical Implementation of a Novel Stereotactic Breast Radiotherapy Device: GammaPod™

    Energy Technology Data Exchange (ETDEWEB)

    Mossahebi, S; Feigenberg, S; Nichols, E; Becker, S; Prado, K; Yi, B; Mutaf, Y [University of Maryland School of Medicine, Baltimore, MD (United States); Niu, Y [Xcision Medical Systems, Rockville, MD (United States); Yu, C [University of Maryland School of Medicine, Baltimore, MD (United States); Xcision Medical Systems, Rockville, MD (United States)

    2016-06-15

    Purpose: GammaPod™, the first stereotactic radiotherapy device for early stage breast cancer treatment, has been recently installed and commissioned at our institution. A multidisciplinary working group applied the failure mode and effects analysis (FMEA) approach to perform a risk analysis. Methods: FMEA was applied to the GammaPod™ treatment process by: 1) generating process maps for each stage of treatment; 2) identifying potential failure modes and outlining their causes and effects; 3) scoring the potential failure modes using the risk priority number (RPN) system based on the product of severity, frequency of occurrence, and detectability (ranging 1–10). An RPN of higher than 150 was set as the threshold for minimal concern of risk. For these high-risk failure modes, potential quality assurance procedures and risk control techniques have been proposed. A new set of severity, occurrence, and detectability values were re-assessed in presence of the suggested mitigation strategies. Results: In the single-day image-and-treat workflow, 19, 22, and 27 sub-processes were identified for the stages of simulation, treatment planning, and delivery processes, respectively. During the simulation stage, 38 potential failure modes were found and scored, in terms of RPN, in the range of 9-392. 34 potential failure modes were analyzed in treatment planning with a score range of 16-200. For the treatment delivery stage, 47 potential failure modes were found with an RPN score range of 16-392. The most critical failure modes consisted of breast-cup pressure loss and incorrect target localization due to patient upper-body alignment inaccuracies. The final RPN score of these failure modes based on recommended actions were assessed to be below 150. Conclusion: FMEA risk analysis technique was applied to the treatment process of GammaPod™, a new stereotactic radiotherapy technology. Application of systematic risk analysis methods is projected to lead to improved quality of

  18. Independent Monte-Carlo dose calculation for MLC based CyberKnife radiotherapy

    Science.gov (United States)

    Mackeprang, P.-H.; Vuong, D.; Volken, W.; Henzen, D.; Schmidhalter, D.; Malthaner, M.; Mueller, S.; Frei, D.; Stampanoni, M. F. M.; Dal Pra, A.; Aebersold, D. M.; Fix, M. K.; Manser, P.

    2018-01-01

    This work aims to develop, implement and validate a Monte Carlo (MC)-based independent dose calculation (IDC) framework to perform patient-specific quality assurance (QA) for multi-leaf collimator (MLC)-based CyberKnife® (Accuray Inc., Sunnyvale, CA) treatment plans. The IDC framework uses an XML-format treatment plan as exported from the treatment planning system (TPS) and DICOM format patient CT data, an MC beam model using phase spaces, CyberKnife MLC beam modifier transport using the EGS++ class library, a beam sampling and coordinate transformation engine and dose scoring using DOSXYZnrc. The framework is validated against dose profiles and depth dose curves of single beams with varying field sizes in a water tank in units of cGy/Monitor Unit and against a 2D dose distribution of a full prostate treatment plan measured with Gafchromic EBT3 (Ashland Advanced Materials, Bridgewater, NJ) film in a homogeneous water-equivalent slab phantom. The film measurement is compared to IDC results by gamma analysis using 2% (global)/2 mm criteria. Further, the dose distribution of the clinical treatment plan in the patient CT is compared to TPS calculation by gamma analysis using the same criteria. Dose profiles from IDC calculation in a homogeneous water phantom agree within 2.3% of the global max dose or 1 mm distance to agreement to measurements for all except the smallest field size. Comparing the film measurement to calculated dose, 99.9% of all voxels pass gamma analysis, comparing dose calculated by the IDC framework to TPS calculated dose for the clinical prostate plan shows 99.0% passing rate. IDC calculated dose is found to be up to 5.6% lower than dose calculated by the TPS in this case near metal fiducial markers. An MC-based modular IDC framework was successfully developed, implemented and validated against measurements and is now available to perform patient-specific QA by IDC.

  19. [Stereotactic body radiation therapy for spinal metastases].

    Science.gov (United States)

    Pasquier, D; Martinage, G; Mirabel, X; Lacornerie, T; Makhloufi, S; Faivre, J-C; Thureau, S; Lartigau, É

    2016-10-01

    After the liver and lungs, bones are the third most common sites of cancer metastasis. Palliative radiotherapy for secondary bone tumours helps relieve pain, improve the quality of life and reduce the risk of fractures. Stereotactic body radiotherapy can deliver high radiation doses with very tight margins, which has significant advantages when treating tumours close to the spinal cord. Strict quality control is essential as dose gradient at the edge of the spinal cord is important. Optimal schedule is not defined. A range of dose-fractionation schedules have been used. Pain relief and local control are seen in over 80%. Toxicity rates are low, although vertebral fracture may occur. Ongoing prospective studies will help clarify its role in the management of oligometastatic patients. Copyright © 2016 Société française de radiothérapie oncologique (SFRO). Published by Elsevier SAS. All rights reserved.

  20. Volumetric Modulated Arc-Based Hypofractionated Stereotactic Radiotherapy for the Treatment of Selected Intracranial Arteriovenous Malformations: Dosimetric Report and Early Clinical Experience

    Energy Technology Data Exchange (ETDEWEB)

    Subramanian, Sai; Srinivas, Chilukuri; Ramalingam, K.; Babaiah, M.; Swamy, S. Thirumalai; Arun, G.; Kathirvel, M.; Ashok, S. [Yashoda Super Specialty Hospital, Hyderabad (India); Clivio, Alessandro [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Fogliata, Antonella, E-mail: antonella.fogliata-cozzi@eoc.ch [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Nicolini, Giorgia [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland); Rao, K. Srinivasa; Reddy, T. Pratap; Amit, Jotwani [Yashoda Super Specialty Hospital, Hyderabad (India); Vanetti, Eugenio; Cozzi, Luca [Oncology Institute of Southern Switzerland, Bellinzona (Switzerland)

    2012-03-01

    Purpose: To evaluate, with a dosimetric and clinical feasibility study, RapidArc (a volumetric modulated arc technique) for hypofractionated stereotactic radiotherapy treatment of large arteriovenous malformations (AVMs). Methods and Materials: Nine patients were subject to multimodality imaging (magnetic resonance, computed tomography, and digital subtraction angiography) to determine nidus and target volumes, as well as involved organs at risk (optical structures, inner ear, brain stem). Plans for multiple intensity-modulated arcs with a single isocenter were optimized for a fractionation of 25 Gy in 5 fractions. All plans were optimized for 6-MV photon beams. Dose-volume histograms were analyzed to assess plan quality. Delivery parameters were reported to appraise technical features of RapidArc, and pretreatment quality assurance measurements were carried out to report on quality of delivery. Results: Average size of AVM nidus was 26.2 cm{sup 3}, and RapidArc plans provided complete target coverage with minimal overdosage (V{sub 100%} = 100% and V{sub 110%} < 1%) and excellent homogeneity (<6%). Organs at risk were highly spared. The D{sub 1%} to chiasm, eyes, lenses, optic nerves, and brainstem (mean {+-} SD) was 6.4 {+-} 8.3, 1.9 {+-} 3.8, 2.3 {+-} 2.2, 0.7 {+-} 0.9, 4.4 {+-} 7.2, 12.2 {+-} 9.6 Gy, respectively. Conformity index (CI{sub 95%}) was 2.2 {+-} 0.1. The number of monitor units per gray was 277 {+-} 45, total beam-on time was 2.5 {+-} 0.3 min. Planning vs. delivery {gamma} pass rate was 98.3% {+-} 0.9%. None of the patients developed acute toxicity. With a median follow-up of 9 months, 3 patients presented with deterioration of symptoms and were found to have postradiation changes but responded symptomatically to steroids. These patients continue to do well on follow-up. One patient developed headache and seizures, which was attributed to intracranial bleed, confirmed on imaging. Conclusion: Hypofractionated stereotactic radiotherapy can be