WorldWideScience

Sample records for curved guide tubes

  1. Experimental study of curved guide tubes for pellet injection

    International Nuclear Information System (INIS)

    Combs, S.K.; Baylor, L.R.; Foust, C.R.; Gouge, M.J.; Jernigan, T.C.; Milora, S.L.

    1997-01-01

    The use of curved guide tubes for transporting frozen hydrogen pellets offers great flexibility for pellet injection into plasma devices. While this technique has been previously employed, an increased interest in its applicability has been generated with the recent ASDEX Upgrade experimental data for magnetic high-field side (HFS) pellet injection. In these innovative experiments, the pellet penetration appeared to be significantly deeper than for the standard magnetic low-field side injection scheme, along with corresponding greater fueling efficiencies. Thus, some of the major experimental fusion devices are planning experiments with HFS pellet injection. Because of the complex geometries of experimental fusion devices, installations with multiple curved guide tube sections will be required for HFS pellet injection. To more thoroughly understand and document the capability of curved guide tubes, an experimental study is under way at the Oak Ridge National Laboratory (ORNL). In particular, configurations and pellet parameters applicable for the DIII-D tokamak and the International Thermonuclear Experimental Reactor (ITER) were simulated in laboratory experiments. Initial test results with nominal 2.7- and 10-mm-diam deuterium pellets are presented and discussed

  2. Production and guide tube transmission of very cold neutrons from pulsed cold source

    International Nuclear Information System (INIS)

    Utsuro, Masahiko; Okumura, Kiyoshi

    1982-01-01

    The intensity and the energy spectra of Very Cold Neutrons (VCN) transmitted through a curved guide tube were measured by using the time-of-flight method of VCN. In the measurements, the curved guide tube having a characteristic neutron velocity of about 70 m/s is combined to a pulsed cold source of an electron linac in an internal target geometry. A space dependence of the VCN spectra was observed on the radial positions of a detector at the guide tube exit. A simple theoretical analysis on the transmission of VCN in the curved guide tube is also presented with taking into consideration about the effects of a finite size and a finite distance of the VCN-emitting source, and simple analytical formulas for the exit spectra of the guide tube are given. Comparisons between the experimental results and the theoretical calculations show good agreements, and the satisfactory performance of the present VCN guide tube assembly was ascertained. These results present also instructive features for understanding the structures and the space dependence of the exit spectra of a neutron guide tube. The VCN spectra at the guide tube exit can be divided into a few energy regions according to the transmission processes of VCN. Thus, the present study provides useful informations for the preparations of a VCN source with a curved guide tube. (author)

  3. Bottom nozzle to guide tube connection

    International Nuclear Information System (INIS)

    Bryan, W.J.

    1991-01-01

    This patent describes a nuclear fuel assembly which includes an upper end fitting and a lower end fitting spaced therefrom and connected thereto by elongated guide tubes of one alloy having an open upper end and a closed lower end with spaced fuel element retaining grids mounted on the guide tubes therebetween, the closed lower ends of the guide tubes including a threaded central passageway and the attachment of the guide tubes to the lower end fitting of another alloy. It comprises: an externally threaded bolt with a first end threadably received in the threaded central passageway of the lower end of the guide tube and a head at the other end of the side of the lower end fitting opposite the guide tube; an interruption in the external threads of the bolt which forms a groove which communicates the interior of the guide tube with the side of the lower end fitting opposite the guide tube and enhances its frictional engagement with the threaded central passageway, thereby to hold and attach the guide tube and lower end fitting firmly together, even through a series of temperature cycles

  4. Spontaneous rotation of the monorail-type guide extension support catheter during advancement of a curved guiding catheter: the potential hazard of twisting with the coronary guidewire.

    Science.gov (United States)

    Hashimoto, Sho; Takahashi, Akihiko; Yamada, Takeshi; Mizuguchi, Yukio; Taniguchi, Norimasa; Hata, Tetsuya; Nakajima, Shunsuke

    2017-11-20

    The extension support guiding catheter has been used to perform complex percutaneous coronary intervention to increase back-up support for the guiding catheter or to ensure deep intubation for device delivery. However, because of its monorail design, advancement of the stent into the distal extension tubing segment is sometimes problematic. Although this problem is considered due to simple collision of the stent, operators have observed tangling between a monorail extension catheter and coronary guidewire in some patients. To examine movement of the collar of the extension guide catheter during advancement of the guiding catheter, we set up an in vitro model in which the guiding catheter had two curves. Rotation of the extension guide catheter was examined by both fluoroscopic imaging and movement of the hub of the proximal end of the catheter. During advancement in the first curve, the collar moved toward the outer side of the curve of the guiding catheter as the operator pushed the shaft of the extension guiding catheter, which overrode the guidewire. After crossing the first curve, the collar moved again to the outer side of the second curve (the inner side of the first curve) of the mother catheter, and then, another clockwise rotation was observed in the proximal hub. Consequently, the collar and tubing portion of the extension guide catheter rotated 360° around the coronary guidewire, and the monorail extension catheter and guidewire became tangled. There is a potential risk of unintentional twisting with the guidewire during advancement into the curved guiding catheter because of its monorail design.

  5. Guide tube sleeve

    International Nuclear Information System (INIS)

    Attix, D.J.

    1983-01-01

    The invention increases the operating capacity of a nuclear reactor by causing a modification in the flow pattern of the coolant which enhances the coolant's effectiveness. The apparatus provides a thin-walled tubular sleeve closely surrounding but not attached to the exterior surface of a guide tube in a fuel assembly. The wall of the sleeve has tabs projecting outwardly into adjacent flow channels. The sleeve is attached to the wall of a cellular void through which passes the guide tube associated with said sleeve. The tabs increase the flow of water in the channel and thus increase the heat transfer

  6. Optimization of curved drift tubes for ultraviolet-ion mobility spectrometry

    Science.gov (United States)

    Ni, Kai; Ou, Guangli; Zhang, Xiaoguo; Yu, Zhou; Yu, Quan; Qian, Xiang; Wang, Xiaohao

    2015-08-01

    Ion mobility spectrometry (IMS) is a key trace detection technique for toxic pollutants and explosives in the atmosphere. Ultraviolet radiation photoionization source is widely used as an ionization source for IMS due to its advantages of high selectivity and non-radioactivity. However, UV-IMS bring problems that UV rays will be launched into the drift tube which will cause secondary ionization and lead to the photoelectric effect of the Faraday disk. So air is often used as working gas to reduce the effective distance of UV rays, but it will limit the application areas of UV-IMS. In this paper, we propose a new structure of curved drift tube, which can avoid abnormally incident UV rays. Furthermore, using curved drift tube may increase the length of drift tube and then improve the resolution of UV-IMS according to previous research. We studied the homogeneity of electric field in the curved drift tube, which determined the performance of UV-IMS. Numerical simulation of electric field in curved drift tube was conducted by SIMION in our study. In addition, modeling method and homogeneity standard for electric field were also presented. The influences of key parameters include radius of gyration, gap between electrode as well as inner diameter of curved drift tube, on the homogeneity of electric field were researched and some useful laws were summarized. Finally, an optimized curved drift tube is designed to achieve homogenous drift electric field. There is more than 98.75% of the region inside the curved drift tube where the fluctuation of the electric field strength along the radial direction is less than 0.2% of that along the axial direction.

  7. Improved guide tube bulge tool

    International Nuclear Information System (INIS)

    Vaill, R.E.; Phillips, W.D.

    1979-01-01

    A guide tube bulge tool for securing control rod guide tubes to a fuel assembly grid, includes a cylinder having several flexible tines each of which is equipped with a semispherical radially outwardly extending projection. A tapered ram fits into the cylinder so as to force the tines outwardly when the ram is pulled into the cylinder while supporting the other tines. (UK)

  8. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    OpenAIRE

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2016-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually...

  9. Control rod guide tube cleaning device

    International Nuclear Information System (INIS)

    Tsuji, Tadashi; Shiota, Yoshiaki.

    1990-01-01

    Since there was no exclusive device for cleaning control rods, no effective cleaning could not be conducted and there was a possibility that obstacles may not be recovered. Then, there are disposed a first pump for supplying pressurized water, a spray nozzle for forming a swirling flow in a control rod guide tube, a second pump for pressurizing water introduced by a sucking pipeline and a collecting device for recovering obstacles intruding to water from the second pump. The pressurized water supplied from the first pump is introduced to a head passing through a blowing pipe and jetted from the spray nozzle to the control rod guide tube. In this case, a swirling stream occurs and obstacles in the control guide tube are mixed into water. The water containing the obstacles passes from the sucking port through a pipeline, introduced to the second pump and recovered to the collecting device. Since there is no water staying portion upon cleaning operation, the obstacles accumulating over the entire region of the bottom of the guide tube can be recovered reliably and efficiently. (N.H.)

  10. Guided waves in magnetospheric tubes of enhanced density

    International Nuclear Information System (INIS)

    Maltsev, Yu.P.; Lyatsky, W.B.

    1981-01-01

    Properties of a guided MHD-wave propagating in a magnetic field tube with the plasma density differing from the ambient density are studied. Like the Alven wave this wave propagates along the magnetic field and is connected with the field-aligned currents flowing at the periphery of the oscillating tube. The guided wave is accompanied by the magnetic field compression, nevertheless the wave moves without attenuation. The guided wave velocity is between the Alven velocities inside and outside the oscillating tube. In a tube of elliptical cross-section the propagation velocity depends on the polarization of the wave. (author)

  11. Characteristics of the JRR-3M neutron guide tubes

    International Nuclear Information System (INIS)

    Suzuki, Masatoshi; Ichikawa, Hiroki; Kawabata, Yuji.

    1993-01-01

    Large scale neutron guide tubes have been installed in the upgraded JRR-3 (Japan Research Reactor No.3, JRR-3M). The total length of the guide tubes is 232m. The neutron fluxes and spectra were measured at the end of the neutron guide tubes. The neutron fluxes of thermal neutron guide tubes with characteristic wavelength of 2A are 1.2 x 10 8 n/cm 2 · s. The neutron fluxes of cold guide tubes are 1.4 x 10 8 n/cm 2 · s with characteristic wavelength of 4A and 2.0 x 10 8 n/cm 2 · s with 6A when the cold neutron source is operated. The neutron spectra measured by time-of-flight method agree well with their designed ones. (author)

  12. A Concentric Tube Continuum Robot with Piezoelectric Actuation for MRI-Guided Closed-Loop Targeting

    Science.gov (United States)

    Su, Hao; Li, Gang; Rucker, D. Caleb; Webster, Robert J.; Fischer, Gregory S.

    2017-01-01

    This paper presents the design, modeling and experimental evaluation of a magnetic resonance imaging (MRI)-compatible concentric tube continuum robotic system. This system enables MRI-guided deployment of a precurved and steerable concentric tube continuum mechanism, and is suitable for clinical applications where a curved trajectory is needed. This compact 6 degree-of-freedom (DOF) robotic system is piezoelectrically-actuated, and allows simultaneous robot motion and imaging with no visually observable image artifact. The targeting accuracy is evaluated with optical tracking system and gelatin phantom under live MRI-guidance with Root Mean Square (RMS) errors of 1.94 and 2.17 mm respectively. Furthermore, we demonstrate that the robot has kinematic redundancy to reach the same target through different paths. This was evaluated in both free space and MRI-guided gelatin phantom trails, with RMS errors of 0.48 and 0.59 mm respectively. As the first of its kind, MRI-guided targeted concentric tube needle placements with ex vivo porcine liver are demonstrated with 4.64 mm RMS error through closed-loop control of the piezoelectrically-actuated robot. PMID:26983842

  13. Control rod guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Suda, Yoshitaka; Ito, Kenji; Matsumoto, Kunio.

    1994-01-01

    Zr having a residual tensile stress of 3 to 10kg/mm 2 in a circumferential direction is used for the main ingredient of a control guide tube of a nuclear reactor. For this purpose, an appropriate correction method such as a roll-correction, tension-correction and press-correction method is applied to an existent Zr-base alloy tube with no substantial residual stress. If the residual tensile stress in the circumferential direction is smaller than 3kg/mm 2 , an effect sufficient to suppress irradiation growth is not obtainable, if it exceeds 10kg/mm 2 , dimensional changes, cracks or the like occurs locally since the wall thickness of the control rod guide tube is small and, accordingly, this often results in failed products as the control guide tube. (N.H.)

  14. Study on the transmission efficiency of curved neutron guide

    International Nuclear Information System (INIS)

    Wang Hongli; Zhang Li; Guo Liping; Yang Tonghua; Zhao Zhixiang

    2004-01-01

    Monte-Carlo simulation program NGT2002 is used to study the transmission efficiency of curved neutron guide from character wavelength, film reflectivity, film material, geometry adjustment error, gap between guides and guide fabricate error, the authors get the transmission efficiency curves of the Ni, supper mirror curved neutron guides, also we have a discuss of how to choose the curved neutron guide's character wavelength. By the simulation results, the authors determine the proper film reflectivity value, guide horizontal geometry adjustment error range, optimized gap value between guide elements and guide width fabricate geometry error range. (authors)

  15. Transmission efficiency of neutron guide tube with alignment errors

    International Nuclear Information System (INIS)

    Kawabata, Yuji; Suzuki, Masatoshi; Sakamoto, Masanobu; Harami, Taikan; Takahashi, Hidetake; Onishi, Nobuaki

    1990-01-01

    The experimental studies on the neutron transmission efficiencies of neutron guide tubes were carried out by using thermal neutrons from the JAERI electron linac. The neutron guide tube facility on a large scale have been planned on the reconstructed JRR-3 in JAERI. The neutron efficiencies of the 1/10 scale neutron guide tube, which is 2 mm width and 1.8 m length, with and without appreciable alignment errors were studied to evaluate the efficiencies of the planned ones. Calculated results by the Neutron Guide Tube Analysis Code 'NEUGT' were also assessed by these neutron experiments. The experimental results agree well with the calculated results by 'NEUGT' even with alignment errors. From this experimental study, the efficiency of the planned neutron guide tubes is estimated to be good enough for the neutron beam experiments. (author)

  16. Radiant absorption characteristics of corrugated curved tubes

    Directory of Open Access Journals (Sweden)

    Đorđević Milan Lj.

    2017-01-01

    Full Text Available The utilization of modern paraboloidal concentrators for conversion of solar radiation into heat energy requires the development and implementation of compact and efficient heat absorbers. Accurate estimation of geometry influence on absorption characteristics of receiver tubes is an important step in this process. This paper deals with absorption characteristics of heat absorber made of spirally coiled tubes with transverse circular corrugations. Detailed 3-D surface-to-surface Hemicube method was applied to compare radiation performances of corrugated and smooth curved tubes. The numerical results were obtained by varying the tube curvature ratio and incident radiant heat flux intensity. The details of absorption efficiency of corrugated tubes and the effect of curvature on absorption properties for both corrugated and smooth tubes were presented. The results may have significance to further analysis of highly efficient heat absorbers exposed to concentrated radiant heating. [Project of the Serbian Ministry of Education, Science and Technological Development, Grant no. 42006

  17. Eddy current testing device for metallic tubes at least locally curved

    International Nuclear Information System (INIS)

    Pigeon, Marcel; Vienot, Claude.

    1975-01-01

    Steam generators, condensers and heat exchangers generally consist of metallic tube bundles, the tubes having a complex geometry. The invention concerns an Eddy current testing device for metallic tubes at least locally curved, operating by translation of a probe inside the tubes [fr

  18. Fuel assembly guide tube

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    This invention is directed toward a nuclear fuel assembly guide tube arrangement which restrains spacer grid movement due to coolant flow and which offers secondary means for supporting a fuel assembly during handling and transfer operations

  19. Control rod guide tube assemblies

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1979-01-01

    A nuclear fuel assembly including sleeves telescoped over end portions of control rod guide tubes which bear against internal shoulders of the sleeves. Upper ends of the sleeves protrude beyond a control rod guide tube spider and are locked in place by means of a resilient cellular lattice or lock that is seated in mating grooves in the outer surfaces of the sleeves. A grapple is provided for disengaging the entire lock structure spider and associated washers, springs and a grill from the end of the fuel assembly in order to enable these components to be removed and subsequently replaced on the fuel assembly after inspection and repair. (UK)

  20. Control rod guide tube assembly

    International Nuclear Information System (INIS)

    Jabsen, F.S.

    1982-01-01

    An improved fuel assembly is described as consisting of a sleeve that engages one end of a control rod guide tube essentially fixing the guide tube to one of the fuel assembly end structures. The end of the sleeve protrudes above the surface of the end fitting. The outer surface of the sleeve has a peripheral groove that engages the resilient sides of a cellular grid or lattice shaped lock. This lock fixes the sleeve in position between the various elements that comprise the end fitting, thereby eliminating a profusion of costly and potentially troublesome nuts, threaded studs and the like that are frequently employed in the fuel assemblies that are presently in use

  1. Modifying the Heysham 2 and Torness guide tubes

    International Nuclear Information System (INIS)

    Salter, I.D.

    1988-01-01

    In 1986 the National Nuclear Corporation carried out the unfuelled engineering run on Torness Reactor One. Subsequent inspection revealed wear on the reactor control rods, following severe spinning caused by gas cross flow swirls at the guide tube castellated ring. The adopted solution was to machine 32 radial holes through the guide tube wall and blank off the existing castellated slots, however, man access to the guide tubes is extremely difficult. This paper describes how Taylor Hitec produced, in only 12 weeks, three remote drilling machines, together with associated debris collection systems, cleaning equipment and remote video/CCTV inspection systems, and then carried out the modifications to the reactors. (author)

  2. Tapered leaf support pin for operating plant guide tubes

    International Nuclear Information System (INIS)

    Land, J.T.; Hopkins, R.J.; Ford, D.E.

    1991-01-01

    This patent describes a mounting system for removably mounting the lower flange of a control rod guide tube over an opening in the upper core plate of a nuclear reactor comprising at least one elongated support pin mounted on the guide tube lower flange and resiliently receivable in a bore formed in the upper core plate. It comprises a support pin having a longitudinal axis and comprising a first pin portion mountable on the guide tube lower flange, and a second pin portion receivable within the upper core plate bore, the second pin portion including a solid body section adjacent the first pin portion and having an outer diameter which is accommodated by the bore by a close clearance fit; locking means mounted on the first pin portion of the support pin for retaining the guide tube lower flange between the solid body section of the second pin portion and the locking means; and a washer disposed around the first pin portion between the locking means and the control rod guide tube flange, the washer and the locking means including mutually engaging rounded surfaces for eliminating bending moments and stresses on the support pin during mounting of the locking means on the first pin portion of the support pin

  3. Guide tube insert assembly for use in a nuclear reactor

    International Nuclear Information System (INIS)

    Hopkins, R.J.; Land, J.T.

    1992-01-01

    This patent describes an internals assembly for a nuclear reactor of the type including an upper support plate and an upper core plate, each having apertures for conducting control rod assemblies into an out of fuel assemblies with the apertures of the upper support plate being aligned with the apertures of the upper core plate, a guide tube insert assembly comprising: an elongated tubular body extending between at least one of the aligned apertures formed in the upper support plate and the upper core plate; guide plates within the elongated tubular body, each of the guide plates having a planar surface extending substantially perpendicular to an axial direction of the tubular body; at least one interconnecting means for interconnecting the guide plates into a guide tube insert assembly such that the guide plates are simultaneously mountable within and removable from the elongated body, and the periphery of each of the guide plates is spaced apart from the inner walls of the elongated tubular body at every point when the insert assembly is mounted within the tubular body, and a stabilizing means for securing the lowermost guide plate of the guide tube insert assembly within the elongated tubular body to prevent rotational and lateral movement between the guide tube insert assembly and the tubular body

  4. Neutron gain for converging guide tubes

    International Nuclear Information System (INIS)

    Mildner, D.F.R.

    1982-01-01

    The method of acceptance diagrams is used to obtain analytical expressions for the neutron gain of a one-dimensional converging guide tube. It is found that the results are more easily expressed by analyzing the acceptance diagram at the exit of the funnel. The results are compared with those for the straight guide. When both guides have the same dimensions at the guide exit, the converging guide has higher transmitted intensity but with greater divergence of the beam. This analytical method is useful to assess the performance of a converging guide, though numerical computations may be required for detailed analysis of a guide system. (orig.)

  5. Curved-straight neutron guide system with uniform spatial intensity distribution

    International Nuclear Information System (INIS)

    Mildner, D.F.R.; Cook, J.C.

    2008-01-01

    The spatial intensity distribution of neutrons emerging from a curved guide is asymmetric, and straight guide sections are sometimes appended to curved guides to make the intensity distribution more nearly uniform. For idealized uniform illumination and in the perfect reflectivity approximation, the spatial-angular acceptance at the exit of the combination can be made exactly uniform for a range of long wavelengths by using a sufficiently long straight section, together with a curved guide whose outer wall coating has a critical angle slightly greater than those of the other guide walls. We refer to this as a 'phase space tailoring guide' where the coatings on the inner wall and straight section are used to define the required divergence at the end of the guide. Increasing the critical angle of the outer wall of the curved section reduces the characteristic wavelength of the curved guide as well as the wavelength at which ideal uniformity can be obtained. The outer wall coating need only be of sufficiently high critical angle to fill the transmittable phase space area of the straight guide uniformly to adequately short wavelength

  6. Effect of drag-reducing polymers on Tubing Performance Curve (TPC) in vertical gas-liquid flows

    NARCIS (Netherlands)

    Shoeibi Omrani, P.; Veltin, J.; Turkenburg, D.H.

    2014-01-01

    This paper discusses the effect of drag reducing polymers on the Tubing Performance Curve (TPC) of vertical air-water flows at near atmospheric conditions. The effect of polymer concentration, liquid and gas flow rates on the pressure drop curve (Tubing Performance Curve) was investigated

  7. Eliminating line of sight in elliptic guides using gravitational curving

    International Nuclear Information System (INIS)

    Kleno, Kaspar H.; Willendrup, Peter K.; Knudsen, Erik; Lefmann, Kim

    2011-01-01

    Eliminating fast neutrons (λ<0.5A) by removing direct line of sight between the source and the target sample is a well established technique. This can be done with little loss of transmission for a straight neutron guide by horizontal curving. With an elliptic guide shape, however, curving the guide would result in a breakdown of the geometrical focusing mechanism inherent to the elliptical shape, resulting in unwanted reflections and loss of transmission. We present a new and yet untried idea by curving a guide in such a way as to follow the ballistic curve of a neutron in the gravitational field, while still retaining the elliptic shape seen from the accelerated reference frame of the neutron. Analytical calculations and ray-tracing simulations show that this method is useful for cold neutrons at guide lengths in excess of 100 m. We will present some of the latest results for guide optimization relevant for instrument design at the ESS, in particular an off-backscattering spectrometer which utilizes the gravitational curving, for 6.66 A neutrons over a guide length of 300 m.

  8. Forming of Zr-4 alloy guide tube with varied diameters

    International Nuclear Information System (INIS)

    Wei Songyan; Tian Zhenye

    1989-10-01

    A new built-up mould method to manufacture Zr-4 alloy guide tubes with varied diameters at the middle of tube is introduced. The guide tube is used in nuclear power plants for guiding the control rods. This method has many advantages such as simple in forming, low cost of manufacturing, no need of special devices and favour of batch processing. The test results show that the accuracy of size, mechanical properties, resistance to corrosion, grain size and hydrogenate orientation of the end-products can meet the technical needs for nuclear reactor operation

  9. Destructive investigations of decommissioned guide tubes: characterization of wear

    International Nuclear Information System (INIS)

    Ambard, A.; Lina, A.; Bosselut, D.; Deforge, D.; Robinot, P.; Thebault, Y.; Paulhies, M.; Maingot, S.

    2011-01-01

    The wear of control rods has been a major maintenance concern for EDF since the nineties. Surface treatment of the rods (nitriding, chrome plating) were developed to deal with this issue. However, the question came to know whether the guiding tube in which those new control rods are inserted are also worn. EDF interest into guide tube wear has been renewed by the slow increase of the drop time in B06 position. EDF performed field examinations and some laboratory experiments to answer to this question. Two guide tubes were extracted from various cores. They were chosen due to their different positions within the core and the different nature of their counter bodies (different control rods surface treatment). Their continuous part were sliced to reduce their activity. Their dimensions were measured and compared to the nominal dimensions. Wear was evidenced with a low level. It is mainly concentrated around the notch. Some distinctions could be made depending on the guiding tube examined. Metallographic examinations were performed using SEM. The wear patterns of the guiding tubes appear similar from those of the control rods, which means that similar wear mechanisms must be involved. A tentative explanation of the increase of the rod drop time in position B06 is proposed. A tentative explanation of the low increase of rod drop time is presented. It could result from the conjunction of a larger pressing force in B06 position than in other position of the core as well as the conformal contact observed. The conformal contact in itself could results from the larger pressing force and the use of hardened rods. The findings of these field examinations have comforted EDF strategy concerning B06 guide tubes: they are changed before their drop time reaches a critical value. (authors)

  10. Optical effects on neutron guide tubes produced by collimation

    International Nuclear Information System (INIS)

    Margaca, F.M.A.; Falcao, A.N.; Sequeira, A.D.; Salgado, J.F.

    1991-01-01

    The collimation of a neutron beam carried by a guide tube is shown to procedure extensive regions of umbra and penumbra on the inner walls of the guide tube whenever a diaphragm is used at the exit. The region of umbra renders useless a certain length of the guide-tube end while in the region of penumbra the guide exhibits a faint luminosity. These optical effects are particularly important for stringent collimation. It is shown that these effects render impossible the implementation of the 'equal-flight-paths' design currently used for small-angle neutron scattering instruments, which use guide segments and a diaphragm in the collimation assembly. As a consequence, these operate most of the time in strongly unmatched configurations. It is shown that the optimized design formerly proposed by the authors, in which, whenever possible, the full luminous source area is used, not only avoids the optical effects mentioned but also guarantees the highest detector count rate. (orig.)

  11. Method and device for monitoring vibration of incore neutron detector guide tube

    International Nuclear Information System (INIS)

    Enomoto, Mitsuhiro; Naito, Norio; Oda, Akira.

    1978-01-01

    Purpose: To easily detect the vibration of an incore neutron detector guide tube and to prevent the occurrence of such accidents that the guide tube comes into contact with the fuel channel box arranged around the periphery thereof to break the channel box. Method: A neutron detector guide tube is disposed within a channel box, and the neutron detector is arranged at the center of the guide tube. Now, when the guide tube vibrates at an inherent number of vibration and a predetermined amplitude, the guide tube moves in the radial direction by the predetermined amplitude part to come into contact with the channel box. Upon this occasion, the detector similarity vibrates, and the output signal is varied by the predetermined neutron flux variation part. This output signal is sent to a comparator through an analyser, and compared with the output signal produced from a device wherein the result analysed at normal time, and the output signal is sent to an alarm device and an indicator, respectively. (Aizawa, K.)

  12. Manufacturing process optimization of nuclear fuel guide tube using HANA alloys

    International Nuclear Information System (INIS)

    Jeong, Yong Hwan; Park, S. Y.; Choi, B. K.; Park, J. Y.; Kim, H. G.; Jeong, Y. I.; Park, D. J.; Lim, J. K.

    2010-08-01

    From this project, the advanced manufacturing parameters which were contained of heat-treatment, reduction rate, and new process (2 step) were considered to increase the guide tube performance of HANA material. It was obtained that the strength and corrosion resistance of HANA material were improved by applying the improve manufacturing parameters when compared to the commercial guide tube material. · Manufacturing parameter study to increase mechanical property -Tensile strength increase of 30% by manufacturing parameter setup when compared to the guide tube specification · Manufacturing parameter study to decrease irradiation growth -Theoretical study of the texture effect on sample specimens related to the irradiation growth · Manufacturing parameter study to increase corrosion resistance -Corrosion resistance increase of 30% by manufacturing parameter setup when compared to the commercial guide tube

  13. Detection and mode identification of axial cracks in the steam generator tube of the nuclear power plant using ultrasonic guided wave

    International Nuclear Information System (INIS)

    Yoon, Byungsik; Yang, Seunghan; Lee, Heejong; Kim, Yongsik

    2010-01-01

    For those people who are involved in NDE, there is a growing concern regarding the significant traveling distance of a guided wave in a structure, which ensures the inspection of a large area of the structure from a single location. A significant number of studies on the guided wave have therefore been made to apply the foregoing to a nondestructive evaluation in many different industries and resulted in an increase in the efficiency of practical guided wave inspection. Unlike the previous studies based mainly on the detection of circumferential flaws, this study is focused on the axial flaw detection in the steam generator tubes of Korean standard nuclear power plants by generating the guided wave by changing frequency and selecting the applicable mode from the dispersion curve for the steam generator tube calculated in this study, where the dispersion-based short-time Fourier transform (D-STFT) algorithm is used to enhance mode identification. In conclusion, the L (0,1) mode at 2.25 MHz is found to be most sensitive in detecting axial flaws in a steam generator tube. (author)

  14. Signal characteristics of guided wave for condenser tube of NPP

    International Nuclear Information System (INIS)

    Min, Lee Dong; Hoon, Choi Sang; Yeong, Yang Tae

    2012-01-01

    A Condenser is a large heat exchanger of the shell and tube type. Cooling water enters through the water box, through the tubesheet and into the tubes(about 80,000 tubes/unit). The shell side of the condenser receives steam from the low pressure turbines exhaust. The steam is cooled to a liquid by passing over the tubes where the cooling water is circulated. Because seawater is used as a coolant, condenser tubes are easily damaged. For such a reason, nondestructive testing conducted periodically. But nondestructive testing takes a lot of manpower and time. Guided wave technique can overcome these shortcomings. In this study, we made an effort evaluating a guided wave defect signal

  15. Locking device of a guiding ring on a plate including an aperture; application to guide tube of nuclear reactor

    International Nuclear Information System (INIS)

    Cauquelin, C.; Poitrenaud, P.

    1987-01-01

    To make easy to take to pieces a guide tube, by a simple tool, this device includes a guide ring. This guide ring aligned with an aperture in a plate has a tubular support fixed to the plate and coaxial with the aperture and lock the guide tube by rotation [fr

  16. Electric arc apparatus for severing split-pin assemblies of guide tubes of nuclear reactors

    International Nuclear Information System (INIS)

    Burns, D.C.; Kauric, C.E.; Persang, J.C.

    1987-01-01

    This patent describes an apparatus for use in the replacement of an old split-pin assembly of a guide tube of a nuclear reactor by a new split-pin assembly, the old split-pin assembly including an old split pin and an old nut securing the old split pin to the guide tube, the old split-pin assembly and the guide tube being radioactive. The apparatus includes a metal disintegration machining tool, the tool having an electrode, means for mounting the tool submerged in a pool of water in engagement with the guide tube and with the old split-pin assembly secured to the guide tube, the tool being so mounted with the electrode in position to coact electrically with the last-named old split-pin assembly but not with the guide tube, and means, connected to the tool, for firing a disintegrating arc between the electrode and the assembly to disintegrate the assembly into readily removable fragments

  17. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments

    International Nuclear Information System (INIS)

    Schmitz-Rode, T.; Guenther, R.W.; Neulen, J.

    2004-01-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  18. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II

    International Nuclear Information System (INIS)

    2010-01-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  19. Ultimate guide to YouTube for business

    CERN Document Server

    2018-01-01

    Ultimate Guide to YouTube for Business helps small business owners create marketing videos to help promote their products, share their story, build a community around their brand without spending a fortune-all the while making money.

  20. Detailed design of neutron guide tubes at the upgraded JRR-3, (1)

    International Nuclear Information System (INIS)

    Harami, Taikan; Umemura, Mutsumi; Ebisawa, Tohru.

    1985-07-01

    JRR-3, currently a heavy water moderated and cooled 10 MW reactor, is to be upgraded to a light water moderated and cooled, heavy water reflected 20 MW reactor. Two guide tubes for thermal neutron and three for cold will be installed in the reactor to transport thermal and cold neutrons from the reactor hall to the experiment hall. This describes the neutron guide tube transmission analysis program, NEUGT, which was developed to assess the design of the neutron guide tubes. The input data plotting program, PLOPINE and the output data plotting program, NEUPLOT are presented in the appendix. The NEUGT program not only calculates a neutron transmission and neutron spectra, assuming the Maxwellian spectra at the entrance of a guide tube, but also analyses the effect of abutment errors. This reports the description and the input data manual of the program in the text. Examples of analysis are given in the appendixes. The program is written in the FORTRAN 77 language for FACOM 380. (author)

  1. Mechanical strength evaluation of the glass base material in the JRR-3 neutron guide tube

    Energy Technology Data Exchange (ETDEWEB)

    Kobayashi, Tetsuya [Japan Atomic Energy Research Inst., Tokai, Ibaraki (Japan). Tokai Research Establishment

    2003-02-01

    The lifetime of the thermal neutron guide tube installed JRR-3 was investigated after 6 years from their first installation. And it was confirmed that a crack had been piercing into the glass base material of the side plate of the neutron guide tube. The cause of the crack was estimated as a static fatigue of the guide tube where an inside of the tube had been evacuated and stressed as well as an embrittlement of the glass base material by gamma ray irradiation. In this report, we evaluate the mechanical strength of the glass base material and estimate the time when the base material gets fatigue fracture. Furthermore, we evaluate a lifetime of the neutron guide tube and confirm the validity of update timing in 2000 and 2001 when the thermal neutron guide tubes T1 and T2 were exchanged into those using the super mirror. (author)

  2. Computational fluid dynamic analysis of a guide tube in a PWR

    International Nuclear Information System (INIS)

    Hofmann, F.; Archambeau, F.; Chaize, C.

    2000-01-01

    Security in nuclear power plants demands severe limitations of the maximal drop time of rod cluster control assemblies. In February 1995, several assemblies of the Chinese plant in Daya Bay failed to comply with these requirements. Electricite De France undertook a research program to get a better insight of this problem since the plant has been built by French and also because the French new four-loops N4 reactor was equipped with the same guide tubes. This paper is limited to a numerical study of the influence of the pressure forces applied to control rods and due to flow circulation through the guide tubes. After a validation test case, a first calculation has been carried out on a simplified N4 guide tube. The sensitivity of the pressure forces to transverse flow and to modifications of the geometry has been determined. The program has been extended to guide tubes used in 1300-MW reactors and similar computations have been done. To make simulations more representative, a global computation of the flow in the whole upper internals plenum (UIP) will be achieved to provide accurate boundary conditions for local calculations with better resolution.

  3. Computational fluid dynamic analysis of a guide tube in a PWR

    International Nuclear Information System (INIS)

    Hofmann, F.; Archambeau, F.

    1997-01-01

    Security in nuclear power plants demands severe limitations of the maximal drop time of rod cluster control assemblies. In February 1995, several assemblies of the Chinese plant in DAYA BAY failed to comply with these requirements. Electricite de France undertook a research program to get a better insight of this problem since the plant has been built by French and also because the French new 4 loops N4 reactor was equipped with the same guide tubes. This paper is limited to a numerical study of the influence of the pressure forces applied to control rods and due to flow circulation through the guide tubes. After a validation test-case, a first calculation has been carried out on a simplified N4 guide tube. The sensitivity of the pressure forces to transverse flow and to modifications of the geometry has been determined. The program has been extended to guide tubes used in 1300 MW reactors and similar computations have been done. To make simulations more representative, a global computation of the flow in the whole upper internals plenum (UIP) will be achieved to provide accurate boundary conditions for local calculations with better resolution. (author)

  4. GTSP, automatic ultrasonic inspection of Guide Tube Support Pin in nuclear power plants

    International Nuclear Information System (INIS)

    2008-01-01

    1 - Description of program or function: GTSP Visitor is a program for automatic detection of known object's position in video frames. It is especially designed for automatic ultrasonic inspection of guide tube support pin (GTSP) in nuclear power plant. 2 - Methods: A GTSP and its position are detected by two-step matched filter algorithm. In first step, a video frame including GTSPs are transformed by DFT. DFTed image is multiplied by matched filter, made from a guide tube image, in frequency domain for estimate Guide Tube center position. Guide Tube areas around estimated center position are erased (pixel values of image are filled with zeros). In next step, image whose guide tube areas were erased is processed as described above but using a different matched filter made from a support pin?s image. Then the positions of two GTSPs are estimated and their orientation is estimated too. Finally its position and orientations are used for control the robot toward the desired position. 3 - Restrictions on the complexity of the problem: Robot control is out of the scope of this program. OpenCV and compatible camera are necessary

  5. Simulation and analysis of the transmission properties of curved-straight neutron guide systems

    International Nuclear Information System (INIS)

    Copley, J.R.D.; Mildner, D.F.R.

    1992-01-01

    This paper reports that the spatial intensity distribution of neutrons emerging from a curved guide is far from uniform, particularly at short wavelengths, and curved guides are sometimes followed by a straight section of guide to make the intensity distribution more uniform. The behavior of neutrons within curved-straight neutron guide systems is examined using both ray-tracing and analytical approaches to the problem. The intensity distribution within the straight guide tends to wash from one side of the guide to the other. The amplitude of this transverse wave decreases with increasing guide length, and the characteristic length of the wave decreases with increasing neutron wavelength

  6. Crack resistance curves determination of tube cladding material

    Energy Technology Data Exchange (ETDEWEB)

    Bertsch, J. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)]. E-mail: johannes.bertsch@psi.ch; Hoffelner, W. [Paul Scherrer Institut, CH-5232 Villigen PSI (Switzerland)

    2006-06-30

    Zirconium based alloys have been in use as fuel cladding material in light water reactors since many years. As claddings change their mechanical properties during service, it is essential for the assessment of mechanical integrity to provide parameters for potential rupture behaviour. Usually, fracture mechanics parameters like the fracture toughness K {sub IC} or, for high plastic strains, the J-integral based elastic-plastic fracture toughness J {sub IC} are employed. In claddings with a very small wall thickness the determination of toughness needs the extension of the J-concept beyond limits of standards. In the paper a new method based on the traditional J approach is presented. Crack resistance curves (J-R curves) were created for unirradiated thin walled Zircaloy-4 and aluminium cladding tube pieces at room temperature using the single sample method. The procedure of creating sharp fatigue starter cracks with respect to optical recording was optimized. It is shown that the chosen test method is appropriate for the determination of complete J-R curves including the values J {sub 0.2} (J at 0.2 mm crack length), J {sub m} (J corresponding to the maximum load) and the slope of the curve.

  7. Humidity Control System In The Neutron Detector Of Guide Tube

    International Nuclear Information System (INIS)

    Alibasya Harahap, Sentot

    2001-01-01

    The probable symptom neutron detector damage as cause decrease resistivity and corrosion in the electrical terminal, further more occasion to voltage failure and leak current in the isolation. The prevent of voltage failure in detector a needed humidity controller's with dry air supply to guide tube with 2 kg/cm exp.2 air pressure and 7 l/min, air flow as soon as continuity dryer process in the guide tube. Reactor shutdown and operation condition of diffusion rate is 0,476 cm exp.3/year and 6,46 cm exp.3/year

  8. Guiding effect of bent macroscopic quartz tube for high current electron beam

    International Nuclear Information System (INIS)

    Zhang Mingwu; Chen Jing; Wu Yehong; Yang Bian; Wang Wei; Xue Yingli; Yu Deyang; Cai Xiaohong

    2012-01-01

    By using an incident electron beam with the high current and high energy, the guiding effect of the bent macroscopic quartz tube for the electron beam has been investigated. The angular distributions of outgoing electrons depending on the current and energy of incident electrons were measured. The dependences of electron transmitted fraction on energy and current of incident electrons are also shown. As the incident electron energy increasing, the electron transmitted fraction increases, but it decreases while the incident electron current increasing. The results have been compared with the present data. This work presents, the process of guiding electrons is essentially different from that of guiding highly charged ions, the guiding electron beam was caused by both elastic and inelastic collisions between electrons and inner walls of quartz tube, rather than self-organized charging effect on the surface of inner wall of quartz tube. (authors)

  9. The Eclipse system for surveying the guide tubes of control rod clusters

    International Nuclear Information System (INIS)

    Pace, Y.M.

    2008-01-01

    Eclipse is a new system developed by Areva to assess the wear of the guide tubes of control rod clusters. This system is based on the projection of a shadow on a light plan in order to record the profile and the internal diameter of a hollow tube. This system allows us to quantify the wear and it can be included in a program dedicated to monitor the wear and master its kinetics. This system has been validated on the guide tubes from the Ringhals units. (A.C.)

  10. Pressure drop-flow rate curves for single-phase steam in Combustion Engineering type steam generator U-tubes during severe accidents

    Energy Technology Data Exchange (ETDEWEB)

    Fynan, Douglas A.; Ahn, Kwang-Il, E-mail: kiahn@kaeri.re.kr

    2016-12-15

    Highlights: • Pressure drop-flow rate curves for superheated steam in U-tubes were generated. • Forward flow of hot steam is favored in the longer and taller U-tubes. • Reverse flow of cold steam is favored in short U-tubes. • Steam generator U-tube bundle geometry and tube diameter are important. • Need for correlation development for natural convention heat transfer coefficient. - Abstract: Characteristic pressure drop-flow rate curves are generated for all row numbers of the OPR1000 steam generators (SGs), representative of Combustion Engineering (CE) type SGs featuring square bend U-tubes. The pressure drop-flow rate curves are applicable to severe accident natural circulations of single-phase superheated steam during high pressure station blackout sequences with failed auxiliary feedwater and dry secondary side which are closely related to the thermally induced steam generator tube rupture event. The pressure drop-flow rate curves which determine the recirculation rate through the SG tubes are dependent on the tube bundle geometry and hydraulic diameter of the tubes. The larger CE type SGs have greater variation of tube length and height as a function of row number with forward flow of steam favored in the longer and taller high row number tubes and reverse flow favored in the short low row number tubes. Friction loss, natural convection heat transfer coefficients, and temperature differentials from the primary to secondary side are dominant parameters affecting the recirculation rate. The need for correlation development for natural convection heat transfer coefficients for external flow over tube bundles currently not modeled in system codes is discussed.

  11. Nut tightening and bolt tension measuring apparatus for control guide tube with ultrasonic probe

    International Nuclear Information System (INIS)

    Lanzoni, M.

    1985-01-01

    Control rods are guided by elements set in the prolongation of the fuel assembly guide-tubes in which the control rods are introduced. These elements are inside guide-tubes fixed on the upper plate of the core by means of pins having a thread on which a nut is screwed bearing on the foot of the guide-tube. The pin is fixed inside the upper core plate by means of its lower part. An insufficient mechanical resistance and even failures have been observed with these pins. These failures have been involved by an unadequate screwing. The present invention proposes to control the pretension during the operation itself with an ultrasonic test [fr

  12. Feasibility study on the guided wave technique for condenser tube in NPP

    International Nuclear Information System (INIS)

    Choi, Sung Nam; Kim, Young Ho; Kim, Hyung Nam; Yoo, Hyun Joo; Hwang, W. G.

    2004-01-01

    The condenser tube is examined by the eddy current test (ECT) method to identify the integrity of the nuclear power plant. Because ECT probe is moved through the tube inside to identify flaws, the ECT probe should be exchanged periodically due to the wear of probe surface in order to remove the noise form the ECT signal. Moreover, it is impossible to examine the tube by ECT method because the ECT probe can not move through the inside due to the deformation such as dent. Recently, the theory of guided wave was established and the equipment applying the theory has been actively developed so as to overcome the limitation of ECT method for the tube inspection of heater exchanger in nuclear power plant. The object of this study is to know the feasibility of applying the guided wave technique to condenser tube in NPP

  13. Nasogastric tube placement with video-guided laryngoscope: A manikin simulator study.

    Science.gov (United States)

    Lee, Xiao-Lun; Yeh, Li-Chun; Jin, Yau-Dung; Chen, Chun-Chih; Lee, Ming-Ho; Huang, Ping-Wun

    2017-08-01

    This study aimed to investigate video-guided laryngoscopy for nasogastric tube placement. This was an observational comparative study performed in a hospital. The participants included volunteers from the medical staff (physicians and nurses) experienced with nasogastric intubation, and non-medical staff (medical students, pharmacists and emergent medical technicians) with knowledge of nasogastric intubation but lacking procedural experience. Medical and non-medical hospital staff performed manual, laryngoscope-assisted and video-guided laryngoscope nasogastric intubation both in the presence and in the absence of an endotracheal tube, using a manikin. Nasogastric intubation times were compared between groups and methods. Using the video-guided laryngoscope resulted in a significantly shorter intubation time compared to the other 2 methods, both with and without an endotracheal tube, for the medical and non-medical staff alike (all p guided laryngoscope without endotracheal intubation, direct laryngoscope with endotracheal intubation and video-guided laryngoscope with endotracheal intubation compared to manual intubation without endotracheal intubation (0.49, 0.63 and 0.72 vs. 5.63, respectively, p ≤ 0.008). For non-medical staff, nasogastric intubation time was significantly shorter using video-guided laryngoscope without endotracheal intubation, direct laryngoscope with endotracheal intubation and video-guided laryngoscope with endotracheal intubation compared to manual intubation without endotracheal intubation (1.67, 1.58 and 0.95 vs. 6.9, respectively, p ≤ 0.002). And mean nasogastric intubation time for video-guided laryngoscope endotracheal intubation was significantly shorter for medical staff than for non-medical staff (0.49 vs. 1.67 min, respectively, p = 0.041). Video-guided laryngoscope reduces nasogastric intubation time compared to manual and direct laryngoscope intubation, which promotes a consistent technique when performed by

  14. An experimental investigation of the propagation of a compact toroid along curved drift tubes

    International Nuclear Information System (INIS)

    Fukumoto, N.; Inoo, Y.; Nomura, M.; Nagata, M.; Uyama, T.; Ogawa, H.; Kimura, H.; Uehara, U.; Shibata, T.; Kashiwa, Y.; Suzuki, S.; Kasai, S.

    2004-01-01

    Compact toroid (CT) injection is a viable technology for fuelling large tokamak reactors in the future. Experimental demonstration of CT injection has thus far been conducted using horizontal injection in the midplane of tokamak devices. However, recent analyses indicate adverse effects of the toroidal magnetic field on CT injection. In order to avoid these adverse effects, the CT would need to be injectable in any direction. We have therefore devised a curved drift tube to change the direction of CT propagation and have experimentally demonstrated its efficacy. It has been observed that a CT can be transported smoothly through curved drift tubes with 45 deg. and 90 deg. bends without any appreciable change in the CT parameters. The magnetic field, electron density and speed of CTs transported through both 45 deg. and 90 deg. bends are similar to those observed in a linear drift tube. (author)

  15. Application of the Guided Wave Technique to the Heat Exchanger Tube in NPP

    International Nuclear Information System (INIS)

    Yang, Dong Soon; Kim, Hyung Nam; Yoo, Hyun Joo

    2005-01-01

    The heat exchanger tube is examined by the method of eddy current test(ECT) to identify the integrity of the nuclear power plant. Because ECT probe is moved through the tube inside to identify flaws, the ECT probe should be exchanged periodically due to the wear of probe surface in order to remove the noise form the ECT signal. Moreover, it is impossible to examine the tube by ECT method because the ECT probe can not move through the inside due to the deformation such as dent. Recently, the theory of guided wave was established and the equipment applying the theory has been actively developed so as to overcome the limitation of ECT method for the tube inspection of heater exchanger in nuclear power plant. The object of this study is to know the application of the guided wave technique to heat exchanger tube in NPP

  16. Eliminating line of sight in elliptic guides using gravitational curving

    DEFF Research Database (Denmark)

    Klenø, Kaspar H.; Willendrup, Peter Kjær; Bergbäck Knudsen, Erik

    2011-01-01

    result in a breakdown of the geometrical focusing mechanism inherent to the elliptical shape, resulting in unwanted reflections and loss of transmission. We present a new and yet untried idea by curving a guide in such a way as to follow the ballistic curve of a neutron in the gravitational field, while...

  17. Clinical evaluation of stethoscope-guided inflation of tracheal tube cuffs.

    Science.gov (United States)

    Kumar, R D C; Hirsch, N P

    2011-11-01

    Tracheal tube cuffs are commonly inflated to pressures exceeding the recommended upper limit of 30 cmH(2)O. We evaluated whether a stethoscope-guided method of cuff inflation results in pressures within the recommended range. Patients were randomly assigned to receive one of two methods of cuff inflation. In the standard 'just seal' group, air was introduced into the tracheal cuff until the audible leak at the mouth disappeared. In the stethoscope-guided group, air was introduced into the cuff until a change from harsh to soft breath sounds occurred, whilst listening with a stethoscope bell placed over the thyroid cartilage. Twenty-five patients were recruited to each group. The median (IQR [range]) cuff pressure in the 'just seal' group was 34 (28-40 [18-49]) cmH(2)O, and in the stethoscope-guided group was 20 (20-26 [16-28]) cmH(2)O, p stethoscope-guided method of tracheal tube cuff inflation is a novel, simple technique that reliably results in acceptable tracheal cuff pressures. © 2011 The Authors. Anaesthesia © 2011 The Association of Anaesthetists of Great Britain and Ireland.

  18. Cutting of Control Rod Guide Tubes and Jet Pumps at Wuergassen NPP/ Germany

    International Nuclear Information System (INIS)

    Ralf Loock

    2006-01-01

    KWW Nuclear Power Plant has been erected and put into operation in the time period 1968 to end of 1971. In 23 years of operation about 73 billions kWh electric power have been generated. The electric rated power was 670 MW. In May 1995 the decommission was started for economical reasons, since April 1997 the demolition is in progress. In autumn 2003 FANP has been called upon to cut the Control Rod Guide Tubes and Jet Pumps. After a 10 months preparatory phase, cutting of the Control Rod Guide Tubes and Jet Pumps was started in September 2004. For radiation protection reasons the Control Rod Guide Tubes and Jet Pumps were cut and packed remote controlled under water. The cutting process had been selected particularly under consideration of radiation protection aspects. A combination of the technologies band sawing and nibbling was assigned for cutting of the Control Rod Guide Tubes and Jet Pumps. The band saw consists of a substructure and of a feed system installed on it. The feed system can be equipped with one or two band saws optionally. A turntable is integrated in the substructure. It is used to support the CRGT respectively the residual piece of the CRGT and to move it out of the cut position after finishing the cutting. After getting the agreement to the specification, the equipment has been designed and manufactured according to the specification preferences. After finishing the internal testing, the factory acceptance test as well as acceptance and functional tests of every facility were carried out. After cold testing being performed successfully, the cutting equipment was installed in the NPP and checked for operational safety additionally. Cutting of the Control Rod Guide Tubes and Jet Pumps has been carried out on two working places inside the fuel element storage pool. During the total project duration on site the processing has been supervised by the radiation protection staff permanently. As a result 110 Control Rod Guide Tubes and 18 Jet Pumps were

  19. Parametric study of guided waves dispersion curves for composite plates

    Science.gov (United States)

    Predoi, Mihai Valentin; Petre, Cristian Cǎtǎlin; Kettani, Mounsif Ech Cherif El; Leduc, Damien

    2018-02-01

    Nondestructive testing of composite panels benefit from the relatively long range propagation of guided waves in sandwich structures. The guided waves are sensitive to delamination, air bubbles inclusions and cracks and can thus bring information about hidden defects in the composite panel. The preliminary data in all such inspections is represented by the dispersion curves, representing the dependency of the phase/group velocity on the frequency for the propagating modes. In fact, all modes are more or less attenuated, so it is even more important to compute the dispersion curves, which provide also the modal attenuation as function of frequency. Another important aspect is the sensitivity of the dispersion curves on each of the elastic constant of the composite, which are orthotropic in most cases. All these aspects are investigated in the present work, based on our specially developed finite element numerical model implemented in Comsol, which has several advantages over existing methods. The dispersion curves and modal displacements are computed for an example of composite plate. Comparison with literature data validates the accuracy of our results.

  20. Mode Identification of Guided Waves in a Curved Pipe

    International Nuclear Information System (INIS)

    Eom, Heung-Seop; Lim, Sa-Hoe; Kim, Jae-Hee

    2006-01-01

    Ultrasonic guided wave technique has been widely employed for the long range inspection of structures such as plates and pipes because it has the ability to propagate over long distances. In the nuclear power field, there recently appeared a need for on-line nondestructive monitoring which can be employed during the operation stage of power plants. As ultrasonic guided waves have shown promise for on-line monitoring of power plants, a lot of work has been done in the institutes and universities on this matter. In the case of detecting defects in simple straight pipes, the dispersion curves obtained from the modeling processes are closely akin to the experimental results. But the modeling of wave propagation in some structures, such as an elbow region of a pipe, is not practical due to elbow echo and unpredictable interface conditions. This paper presents an experimental approach to identify the most dominant modes of guided waves in a curved region of a pipe, which is a key factor in detecting flaws in a pipe

  1. Ion guiding in macro-size insulating capillaries: straight, tapered, and curved shapes

    Science.gov (United States)

    Kojima, Takao M.

    2018-02-01

    When keV energy ions are injected into a tilted insulating capillary, a certain fraction of the injected ions are transported through the tilt angle of the capillary. This ion guiding phenomenon is considered to be caused by a self-organizing charge distribution, where the inner wall of the capillary becomes charged by initial incoming ions. The charge distribution, which is formed, can guide following ions toward the exit of the capillary. Since the initial discovery of this effect, studies of ion guiding by insulating capillaries have been extended to various materials, and different sizes and shapes of capillaries. In recent years, some investigations of the guiding effect of macro-size curved capillaries have also been reported. In this review, relevant studies in a history of ion guiding in curved capillaries are discussed and future directions in this field are considered.

  2. On guided circumferential waves in soft electroactive tubes under radially inhomogeneous biasing fields

    Science.gov (United States)

    Wu, Bin; Su, Yipin; Chen, Weiqiu; Zhang, Chuanzeng

    2017-02-01

    Soft electroactive (EA) tube actuators and many other cylindrical devices have been proposed recently in literature, which show great advantages over those made from conventional hard solid materials. However, their practical applications may be limited because these soft EA devices are prone to various failure modes. In this paper, we present an analysis of the guided circumferential elastic waves in soft EA tube actuators, which has potential applications in the in-situ nondestructive evaluation (NDE) or online structural health monitoring (SHM) to detect structural defects or fatigue cracks in soft EA tube actuators and in the self-sensing of soft EA tube actuators based on the concept of guided circumferential elastic waves. Both circumferential SH and Lamb-type waves in an incompressible soft EA cylindrical tube under inhomogeneous biasing fields are considered. The biasing fields, induced by the application of an electric voltage difference to the electrodes on the inner and outer cylindrical surfaces of the EA tube in addition to an axial pre-stretch, are inhomogeneous in the radial direction. Dorfmann and Ogden's theory of nonlinear electroelasticity and the associated linear theory for small incremental motion constitute the basis of our analysis. By means of the state-space formalism for the incremental wave motion along with the approximate laminate technique, dispersion relations are derived in a particularly efficient way. For a neo-Hookean ideal dielectric model, the proposed approach is first validated numerically. Numerical examples are then given to show that the guided circumferential wave propagation characteristics are significantly affected by the inhomogeneous biasing fields and the geometrical parameters. Some particular phenomena such as the frequency veering and the nonlinear dependence of the phase velocity on the radial electric voltage are discussed. Our numerical findings demonstrate that it is feasible to use guided circumferential

  3. Fabrication of a pressurized water reactor fuel element prototype with Zy-control rod guide tubes

    International Nuclear Information System (INIS)

    Bezold, H.; Romeiser, H.J.

    1978-10-01

    A prototype fuel assembly with zircaloy guide was fabricated by mass production methods. The fastening of the Inconel spacer grids to the guide tubes and the transition joint for fixing the tubes to the stainless stell upper end-fitting of the assembly were investigated. Tools and welding devices were developed for the construction of the skeleton. (orig.) [de

  4. Improvement of the vibration of the test fuel(Type-B) with a guide tube under operational condition

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Dong Seung; Yim, Jeong Sik; Lim, I. C. [Korea Atomic Energy Research Institute, Taejon (Korea)

    1999-04-01

    The Type-B test fuel for the Hanaro has a flexible guide tube on top of the fuel to lead and guide the instrumentation wires. Depending on the flow condition in the reactor, the fuel is susceptible to vibration. During the test operation of the fuel, a fairly large amplitude vibration was observed and the possibility of flow tube contact with adjacent flow tubes, due to the excessive vibration of the fuel, and consequent wear or defect of the flow tubes were raised. Thus, to know the vibration characteristics as well as whether the flow tube contact each other, analyses of the Type-B fuel the dummy fuel were performed by BEVIRA and ANSYS. Besides the analyses, vibration tests using the dummy fuel in air and with Type-B fuel in the core at zero power under operational flow condition were executed. The results from the analyses were compared with those from tests to validate the analyses. From the deflection test of the dummy fuel in air to get the maximum displacement of the flow tube at the top, the flow tube were found to contact each other. For the prevention of the contact of the flow tubes caused by the excessive vibration of the guide tube, an additional support to the guide tube was proposed. With the additional support, analysis and in core vibration test under operational flow condition were conducted and there found to be no excessive vibration any more. 6 refs., 16 figs., 6 tabs. (Author)

  5. Advantages of Direct Insertion of a Straight Probe Without a Guide Tube During Anterior Odontoid Screw Fixation of Odontoid Fractures.

    Science.gov (United States)

    Park, Jin Hoon; Kang, Dong-Ho; Lee, Moon Kyu; Yoo, Byoungwoo; Jung, Sang Ku; Hwang, Soo-Hyun; Kim, Jeoung Hee; Oh, Sunkyu; Lee, Eun Jung; Jeon, Sang Ryong; Roh, Sung Woo; Rhim, Seung Chul

    2016-05-01

    A retrospective cohort study. The aim of this study was to compare the anterior odontoid screw fixation (AOSF) with a guide tube or with a straight probe. AOSF associates with several complications, including malpositioning, fixation loss, and screw breakage. Screw pull-out from the C2 body is the most common complication. All consecutive patients with type II or rostral shallow type III odontoid fractures who underwent AOSFs during the study period were enrolled retrospectively. The guide-tube AOSF method followed the standard published method except C3 body and C2-3 disc annulus rimming was omitted to prevent disc injury; instead, the guide tube was anchored at the anterior inferior C2 vertebra corner. After 2 screw pull-outs, the guide-tube cohort was analyzed to identify the cause of instrument failure. Thereafter, the straight-probe method was developed. A guide tube was not used. A small pilot hole was made on the most anterior side of the inferior endplate, followed by insertion of a 2.5 mm straight probe through the C2 body. Non-union and instrument failure rates and screw-direction angles of the guide-tube and straight-probe groups were recorded. The guide-tube group (n = 13) had 2 screw pull-outs and 1 non-union. The straight-probe group (n = 8) had no complications and significantly larger screw-direction angles than the guide-tube group (60.5 ± 4.63 vs. 54.8 ± 3.82 degrees; P = 0.047). Straight-probe AOSF yielded larger direction angles without injuring bone and disc. Complications were absent. The procedure was easier than guide-tube AOSF and assured sufficient engagement, even in horizontal fracture orientation cases. 3.

  6. Sprouting angiogenesis in human midterm uterus and fallopian tube is guided by endothelial tip cells.

    Science.gov (United States)

    Rusu, M C; Motoc, A G M; Pop, F; Folescu, R

    2013-01-01

    Five samples of human midterm fetal uterus and fallopian tube (four donor bodies) were used to assess whether or not processes of angiogenesis are guided by endothelial tip cells (ETCs), and if cytokine-receptors, such as CD117/c-kit and PDGFR-α, are expressed in the microenvironment of the endothelial tubes. CD34 labeled microvessels in the uterine wall (myometrium and endometrium) and in the wall of the uterine (fallopian) tube, and accurately identified ETCs in both organs. We conclude that sprouting angiogenesis in the developing human female tract is guided by ETCs. Moreover, CD117/c-kit antibodies labeled mural networks of pericytes, α-SMA-positive and desmin-negative, related to the endometrial (but not myometrial) microvessels, and similar labeling was identified in the wall of the uterine tube. PDGFR-α positive labeling, stromal and pericytary, was also found. Thus, sprouting angiogenesis in human fetal genital organs appears to be guided by tip cells and is influenced by tyrosine kinase receptor signaling.

  7. Evaluation of friction forces between control bars and guide tubes of CAREM fuel element

    International Nuclear Information System (INIS)

    Ghiselli, Alberto M.; Fiori, Jose M.; Yedros, Pablo A.

    2003-01-01

    The design of the MSAC (Mecanismo del Sistema de ajuste y control, Mechanism of the Adjustment and control system, MACS) for CAREM reactor shall consider all loads that the reactor shall support during its operation. Several charges are originated by friction forces produced on contact points of the control Bars/Guide tubes assembly against other components. A test facility was designed and manufactured for the determination of friction components and the damping characteristics of the assembly formed by guide tubes fuel element, the control bars and the guide of the bar of the MACS. In this work a description of the test performed and the results obtained is presented. (author)

  8. Balloon dilation of the eustachian tube in a cadaver model: technical considerations, learning curve, and potential barriers.

    Science.gov (United States)

    McCoul, Edward D; Singh, Ameet; Anand, Vijay K; Tabaee, Abtin

    2012-04-01

    The surgical management options for eustachian tube dysfunction have historically been limited. The goal of the current study was to evaluate the technical considerations, learning curve, and potential barriers for balloon dilation of the eustachian tube (BDET) as an alternative treatment modality. Prospective preclinical trial of BDET in a cadaver model. A novel balloon catheter device was used for eustachian tube dilation. Twenty-four BDET procedures were performed by three independent rhinologists with no prior experience with the procedure (eight procedures per surgeon). The duration and number of attempts of the individual steps and overall procedure were recorded. Endoscopic examination of the eustachian tube was performed after each procedure, and the surgeon was asked to rate the subjective difficulty on a five-point scale. Successful completion of the procedure occurred in each case. The overall mean duration of the procedure was 284 seconds, and a mean number of 1.15 attempts were necessary to perform the individual steps. The mean subjective procedure difficulty was noted as somewhat easy. Statistically shorter duration and subjectively easier procedure were noted in the second compared to the first half of the series, indicating a favorable learning curve. Linear fissuring within the eustachian tube lumen without submucosal disruption (nine procedures, 37%) and with submucosal disruption (five procedures, 21%) were noted. The significance of these physical findings is unclear. Preclinical testing of BDET is associated with favorable duration, learning curve, and overall ease of completion. Clinical trials are necessary to evaluate safety and efficacy. Copyright © 2012 The American Laryngological, Rhinological, and Otological Society, Inc.

  9. Influence of structure improvement of guide tubes and bundles in pressurized water reactor (PWR) on drop of control rods

    International Nuclear Information System (INIS)

    Shen Xiuzhong; Yu Pingan; Yang Guanyue

    1996-01-01

    In order to alleviate the cross hydraulic load on control rod guide tubes and bundles, some protective sleeves are added to those near the upper plenum outlet nozzles (4 symmetric bundles: 02-26, 03-25, 11-29, 12-28). In a 1/4 scale transparent model of the PWR upper plenum of Qinshan Nuclear Power Station, water was chosen as the fluid and hydraulic experiments with improved control rod guide tubes and bundles were carried out. The results were carefully compared with those of the experiments with unimproved control rod guide tubes and bundles. It is concluded that adding protective sleeves to the control rod guide tubes and bundles near the outlet nozzles will help to lighten the hydraulic load on them and make certain of the free movement and rapid dropping of control rods in the tubes and bundles in emergency by order

  10. Fluoroscopically guided fallopian tube recanalization with a simplified set of instruments; Durchleuchtungsgesteuerte Eileiter-Rekanalisation mit vereinfachtem Instrumentarium

    Energy Technology Data Exchange (ETDEWEB)

    Schmitz-Rode, T.; Guenther, R.W. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik; Neulen, J. [Technische Hochschule Aachen (Germany). Frauenklinik fuer gynaekologische Endokrinologie und Reproduktionsmedizin

    2004-10-01

    Purpose: Fluoroscopically guided transcervical fallopian tube recanalization is recognized as an important step in the workup of female infertility. In the present study, a simplified set of recanalization instruments was tested. Materials and Methods: Forty-two women with infertility and sonographically confirmed or suspected uni- or bilateral tubal occlusion were examined. After vaginal placement of a plastic speculum and fixation of a tenaculum, a 4F glide catheter with a 0.89 mm glidewire was advanced transcervically. After documentation of tubal occlusion by hysterosalpingography, the uterotubal junction was catheterized with the same instruments. Under fluoroscopic guidance, the glidewire was negotiated beyond the intramural portion of the tube. Selective salpingography documented the outcome of the recanalization. Results: Hysterosalpingography confirmed tubal occlusions in 26 of 42 patients (in 12 cases unilateral and in 14 cases bilateral). Fallopian tube recanalization was successful in 23 of 26 patients (technical success rate of 88%). The resulting fertility rate was 30% (7/23), without any ectopic pregnancy. Complications such as tubal perforation, infection, or bleeding did not occur. Tubal catheterization was straightforward and smooth in 17/23 cases. For a hyperflexed uterus (6/23), a curved tip of the catheter was helpful in tubal probing. (orig.)

  11. Fluoroscopy-guided balloon dilation in patients with Eustachian tube dysfunction

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kun Yung; Tsauo, Jiaywei; Song, Ho-Young [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Park, Hong Ju; Kang, Woo Seok [University of Ulsan College of Medicine, Department of Otorhinolaryngology-Head and Neck Surgery, Asan Medical Center, Seoul (Korea, Republic of); Park, Jung-Hoon [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); University of Ulsan College of Medicine, Department of Biomedical Engineering Research Center, Asan Medical Center, Seoul (Korea, Republic of); Wang, Zhe [University of Ulsan College of Medicine, Department of Radiology and Research Institute of Radiology, Asan Medical Center, Seoul (Korea, Republic of); Tianjin Medical University General Hospital, Department of Radiology (China)

    2018-03-15

    To prospectively evaluate the technical feasibility and safety of fluoroscopy-guided balloon dilation in patients with Eustachian tube (ET) dysfunction. Patients who could not do a Valsalva manoeuvre for more than 6 months and diagnosed with chronic otitis media or ET dysfunction were prospectively enrolled. A 0.035-in. guide wire and 6-mm long balloon catheter with a diameter of 2 mm were used to dilate the cartilaginous portion of the ET under fluoroscopic guidance. The balloon was inflated by manual injection twice for 1 min each time. Clinical outcomes were assessed by the patient's ability to perform a Valsalva manoeuvre, and symptoms were assessed using the 7-item Eustachian Tube Dysfunction Questionnaire (ETDQ-7) score. Balloon dilation was attempted in a total of ten adult patients from October 2016 to March 2017. Technical success was achieved in all procedures (10/10). Ninety percent (9/10) of the balloons were fully dilated without waist deformity. There were no major complications. All patients were able to perform a Valsalva manoeuvre at the time of their last visit and/or improvement of at least one ETDQ-7 score. Fluoroscopy-guided balloon dilation seems to be technically feasible and safe in the treatment of ET dysfunction. (orig.)

  12. Remotely controlled device for tightening, the nuts on locating pins for guide tubes in pressurized water reactors

    International Nuclear Information System (INIS)

    Styskal, P.

    1991-01-01

    The device has a support having a horizontal guide radial to the guide tube with a trolley moving on the guide and mounted on it a tool carrier. The tightening tool it self consists of a motor and an assembly of reducing gears mounted on the tool carrier. The final gear wheel in the assembly turns about a vertical axis and has a ferrule on its face for tightening the nut of the guide tube locating pin. The force of reaction on the tool carrier may be measured thus allowing the torque applied by the tool to be regulated [fr

  13. High pressure thimble/guide tube seal fitting with built-in low pressure seal especially suitable for facilitated and more efficient nuclear reactor refueling service

    International Nuclear Information System (INIS)

    Bhatt, P.N.; Blaushield, R.M.

    1991-01-01

    This patent describes a HP/LP seal arrangement for an elongated guide tube and an elongated thimble disposed therein. The guide tube and thimble extending outwardly from the core of a nuclear reactor to a seal table where the guide tube is welded to the seal table to provide a high pressure seal relative thereto. It comprises: a tubular seal fitting disposed in alignment with the guide tube with the thimble extending therethrough on the low pressure side of the seal table; first high pressure sealing means coupling one end of the fitting to an end of the guide tube to prevent leakage from within the guide tube; inwardly facing thread means disposed adjacent the other and outer end of the seal fitting; a nut having an opening through which the thimble extends and further having outwardly facing threading in mating engagement with the fitting thread means; the fitting having a seal seat spaced longitudinally inwardly from the thread means and facing the fitting outer end and further disposed annularly about the inner surface of the fitting; deformable ring seal means; second releasable high pressure sealing means coupling the thimble to the outer end portion of the guide tube

  14. Calculation modelling of the RCCA movement through bowed FA guide tubes

    International Nuclear Information System (INIS)

    Razoumovsky, D.V.; Lihkachev, Yu.I.; Troyanov, V.M.

    2000-01-01

    Rod control cluster assembly movement through the bowed guide tubes is considered. The movement equation is presented with some of the assumptions and special attention is paid to the determination of the mechanical friction force. The numerical algorithm is described and some results of parametric studies are presented. (author)

  15. Heat exchanger tube tool

    International Nuclear Information System (INIS)

    Gugel, G.

    1976-01-01

    Certain types of heat-exchangers have tubes opening through a tube sheet to a manifold having an access opening offset from alignment with the tube ends. A tool for inserting a device, such as for inspection or repair, is provided for use in such instances. The tool is formed by a flexible guide tube insertable through the access opening and having an inner end provided with a connector for connection with the opening of the tube in which the device is to be inserted, and an outer end which remains outside of the chamber, the guide tube having adequate length for this arrangement. A flexible transport hose for internally transporting the device slides inside of the guide tube. This hose is long enough to slide through the guide tube, into the heat-exchanger tube, and through the latter to the extent required for the use of the device. The guide tube must be bent to reach the end of the heat-exchanger tube and the latter may be constructed with a bend, the hose carrying anit-friction elements at interspaced locations along its length to make it possible for the hose to negotiate such bends while sliding to the location where the use of the device is required

  16. Mode Selection for Axial Flaw Detection in Steam Generator Tube Using Ultrasonic Guided Wave

    International Nuclear Information System (INIS)

    Yoon, Byung Sik; Yang, Seung Han; Guon, Ki Il; Kim, Yong Sik

    2009-01-01

    The eddy current testing method is mainly used to inspect steam generator tube during in-service inspection period. But the general problem of assessing the structural integrity of the steam generator tube using eddy current inspection is rather complex due to the presence of noise and interference signal under various conditions. However, ultrasonic testing as a nondestructive testing tool has become quite popular and effective for the flaw detection and material characterization. Currently, ultrasonic guided wave is emerging technique in power industry because of its various merits. But most of previous studies are focused on detection of circumferential oriented flaws. In this study, the steam generator tube of nuclear power plant was selected to detect axially oriented flaws and investigate guided wave mode identification. The longitudinal wave mode is generated using piezoelectric transducer frequency from 0.5 MHz, 1.0 MHz, 2.25MHz and 5MHz. Dispersion based STFT algorithm is used as mode identification tool

  17. J-resistance curves for Inconel 690 and Incoloy 800 nuclear steam generators tubes at room temperature and at 300 °C

    Energy Technology Data Exchange (ETDEWEB)

    Bergant, Marcos A., E-mail: marcos.bergant@cab.cnea.gov.ar [Gerencia CAREM, Centro Atómico Bariloche (CNEA), Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Yawny, Alejandro A., E-mail: yawny@cab.cnea.gov.ar [División Física de Metales, Centro Atómico Bariloche (CNEA) / CONICET, Av. Bustillo 9500, San Carlos de Bariloche 8400 (Argentina); Perez Ipiña, Juan E., E-mail: juan.perezipina@fain.uncoma.edu.ar [Grupo Mecánica de Fractura, Universidad Nacional del Comahue / CONICET, Buenos Aires 1400, Neuquén 8300 (Argentina)

    2017-04-01

    The structural integrity of steam generator tubes is a relevant issue concerning nuclear plant safety. In the present work, J-resistance curves of Inconel 690 and Incoloy 800 nuclear steam generator tubes with circumferential and longitudinal through wall cracks were obtained at room temperature and 300 °C using recently developed non-standard specimens' geometries. It was found that Incoloy 800 tubes exhibited higher J-resistance curves than Inconel 690 for both crack orientations. For both materials, circumferential cracks resulted into higher fracture resistance than longitudinal cracks, indicating a certain degree of texture anisotropy introduced by the tube fabrication process. From a practical point of view, temperature effects have found to be negligible in all cases. The results obtained in the present work provide a general framework for further application to structural integrity assessments of cracked tubes in a variety of nuclear steam generator designs. - Highlights: •Non-standard fracture specimens were obtained from nuclear steam generator tubes. •Specimens with circumferential and longitudinal through-wall cracks were used. •Inconel 690 and Incoloy 800 steam generator tubes were tested at 24 and 300 °C. •Fracture toughness for circumferential cracks was higher than for longitudinal cracks. •Incoloy 800 showed higher fracture toughness than Inconel 690 steam generator tubes.

  18. Mapping Self-Guided Learners' Searches for Video Tutorials on YouTube

    Science.gov (United States)

    Garrett, Nathan

    2016-01-01

    While YouTube has a wealth of educational videos, how self-guided learners use these resources has not been fully described. An analysis of search engine queries for help with the use of Microsoft Excel shows that few users search for specific features or functions but instead use very general terms. Because the same videos are returned in…

  19. Plugger guide for aligning an end plug and a fuel rod tube end

    International Nuclear Information System (INIS)

    Klapper, K.K.; Boatwright, D.A.

    1987-01-01

    A pin driving tool is described for inserting or removing pins from teeth on a digging means, comprising: fuel rod tube toward an end plug for application of the end plug into the tube end, the apparatus comprising: (a) a guide housing having an elongated central longitudinal bore with one end for receiving the end plug and an opposite end for receiving the fuel rod tube end; (b) sets of rolling elements disposed in the housing at axially spaced positions along and about the bore thereof. The rolling elements in each set are positioned in fixed relation with respect to one another to receive the fuel rod tube end therebetween and align the tube end with the end plug as the tube end is moved through the bore and into engagement with the end plug; and (c) retaining means disposed adjacent to the open end of the housing bore for engaging the end plug so as to maintain it in a stationary seated position at the one end of the housing bore

  20. Coaxial guiding assembly for internal through-passing probe for eddy current testing of tubes

    International Nuclear Information System (INIS)

    Kubis, S.; Holec, P.

    1989-01-01

    The device features guiding cases mounted on springs provided on the peripheries with two rows of radial openings into which are wound flexible fibres parallel with the case axis. The advantage of the design is that active elements which provide the coaxial guiding of the probe are oriented in the direction of the probe movement. This significantly reduces friction between the probe and the internal wall of the tube and thereby also wear of the guide parts of the probe. (J.B.). 2 figs

  1. Heat transfer and pressure drop characteristics of the tube bank fin heat exchanger with fin punched with flow redistributors and curved triangular vortex generators

    Science.gov (United States)

    Liu, Song; Jin, Hua; Song, KeWei; Wang, LiangChen; Wu, Xiang; Wang, LiangBi

    2017-10-01

    The heat transfer performance of the tube bank fin heat exchanger is limited by the air-side thermal resistance. Thus, enhancing the air-side heat transfer is an effective method to improve the performance of the heat exchanger. A new fin pattern with flow redistributors and curved triangular vortex generators is experimentally studied in this paper. The effects of the flow redistributors located in front of the tube stagnation point and the curved vortex generators located around the tube on the characteristics of heat transfer and pressure drop are discussed in detail. A performance comparison is also carried out between the fins with and without flow redistributors. The experimental results show that the flow redistributors stamped out from the fin in front of the tube stagnation points can decrease the friction factor at the cost of decreasing the heat transfer performance. Whether the combination of the flow redistributors and the curved vortex generators will present a better heat transfer performance depends on the size of the curved vortex generators. As for the studied two sizes of vortex generators, the heat transfer performance is promoted by the flow redistributors for the fin with larger size of vortex generators and the performance is suppressed by the flow redistributors for the fin with smaller vortex generators.

  2. Dynamos driven by poloidal flows in untwisted, curved and flat Riemannian diffusive flux tubes

    International Nuclear Information System (INIS)

    De Andrade, L.C.G.

    2010-01-01

    Recently Vishik anti-fast dynamo theorem has been tested against non-stretching flux tubes (Phys. Plasmas, 15 (2008)). In this paper, another anti dynamo theorem, called Cowling's theorem, which states that axisymmetric magnetic fields cannot support dynamo action, is carefully tested against thick tubular and curved Riemannian untwisted flows, as well as thin flux tubes in diffusive and diffusion less media. In the non-diffusive media Cowling's theorem is not violated in thin Riemann-flat untwisted flux tubes, where the Frenet curvature is negative. Nevertheless the diffusion action in the thin flux tube leads to a dynamo action driven by poloidal flows as shown by Love and Gubbins (Geophysical Res., 23 (1996) 857) in the context of geo dynamos. Actually it is shown that a slow dynamo action is obtained. In this case the Frenet and Riemann curvature still vanishes. In the case of magnetic filaments in diffusive media dynamo action is obtained when the Frenet scalar curvature is negative. Since the Riemann curvature tensor can be expressed in terms of the Frenet curvature of the magnetic flux tube axis, this result can be analogous to a recent result obtained by Chicone, Latushkin and Smith, which states that geodesic curvature in compact Riemannian manifolds can drive dynamo action in the manifold. It is also shown that in the absence of diffusion, magnetic energy does not grow but magnetic toroidal magnetic field can be generated by the poloidal field, what is called a plasma dynamo.

  3. Evaluation of Two Passes Cold Pilgering Property for PLUS7TM Guide Thimble and Instrumentation Tubing

    Energy Technology Data Exchange (ETDEWEB)

    Park, Min Young; Park, Ki Bum; Kim, In Kyu; Lee, Young Hee; Kahng, Jong Yeol [KEPCO Nuclear Fuel Co., Daejeon (Korea, Republic of)

    2015-05-15

    The thermo-mechanical property of zirconium alloy tube is well known to be influenced by pilgering pass schedule and its tooling; thus the control of its microstructure and mechanical property in the final tube production stage for nuclear fuel applications is a major concern of tube manufacture. To fabricate final tube, the 3 passes pilgering is applied in general by using TREX(Tube Reduced EXtrusion), 63.5mm outer diameter(OD), in KEPCO NF and most of Zr tube manufacturing companies. They are also taking big efforts to reduce pilgering step for the sake of increasing the efficiency of production in the forming stage of tube. The objective of this study is to develop two passes of pilgering schedule from the conventional three passes of pilgering schedule for manufacturing the Guide Thimble and Instrumentation tube conforming to specification, which are newly developing component for the advanced nuclear fuel assembly in KEPCO NF. CSR, hydride orientation, and structural integrity are well conformed to the desired targets so it is expected that both die and mandrel were newly designed for the PLUS7TM guide thimble and instrumentation tube with higher Q factor for two passes of pilgering at 50LC and 25LC pilger machine, instead of three passes of pilgering, are able to be applicable to this design of fuel component. If developed two passes pilgering is applied to current manufacturing process, it would improve not only productivity but also yield rate by reducing 3 steps(pilgering, heat-treatment, pickiling and cleaning) of manufacturing process. But additional tests(including in-pile test) should be performed in order to evaluate integrity in reactor.

  4. Computed Tomographic Window Setting for Bronchial Measurement to Guide Double-Lumen Tube Size.

    Science.gov (United States)

    Seo, Jeong-Hwa; Bae, Jinyoung; Paik, Hyesun; Koo, Chang-Hoon; Bahk, Jae-Hyon

    2018-04-01

    The bronchial diameter measured on computed tomography (CT) can be used to guide double-lumen tube (DLT) sizes objectively. The bronchus is known to be measured most accurately in the so-called bronchial CT window. The authors investigated whether using the bronchial window results in the selection of more appropriately sized DLTs than using the other windows. CT image analysis and prospective randomized study. Tertiary hospital. Adults receiving left-sided DLTs. The authors simulated selection of DLT sizes based on the left bronchial diameters measured in the lung (width 1,500 Hounsfield unit [HU] and level -700 HU), bronchial (1,000 HU and -450 HU), and mediastinal (400 HU and 25 HU) CT windows. Furthermore, patients were randomly assigned to undergo imaging with either the bronchial or mediastinal window to guide DLT sizes. Using the underwater seal technique, the authors assessed whether the DLT was appropriately sized, undersized, or oversized for the patient. On 130 CT images, the bronchial diameter (9.9 ± 1.2 mm v 10.5 ± 1.3 mm v 11.7 ± 1.3 mm) and the selected DLT size were different in the lung, bronchial, and mediastinal windows, respectively (p study, oversized tubes were chosen less frequently in the bronchial window than in the mediastinal window (6/110 v 23/111; risk ratio 0.38; 95% CI 0.19-0.79; p = 0.003). No tubes were undersized after measurements in these two windows. The bronchial measurement in the bronchial window guided more appropriately sized DLTs compared with the lung or mediastinal windows. Copyright © 2017 Elsevier Inc. All rights reserved.

  5. Experimental and clinical trial of measuring urinary velocity with the pitot tube and a transrectal ultrasound guided video urodynamic system.

    Science.gov (United States)

    Tsujimoto, Yukio; Nose, Yorihito; Ohba, Kenkichi

    2003-01-01

    The pitot tube is a common device to measure flow velocity. If the pitot tube is used as an urodynamic catheter, urinary velocity and urethral pressure may be measured simultaneously. However, to our knowledge, urodynamic studies with the pitot tube have not been reported. We experimentally and clinically evaluated the feasibility of the pitot tube to measure urinary velocity with a transrectal ultrasound guided video urodynamic system. We carried out a basal experiment measuring flow velocity in model urethras of 4.5-8.0 mm in inner diameter with a 12-Fr pitot tube. In a clinical trial, 79 patients underwent transrectal ultrasound guided video urodynamic studies with the 12-Fr pitot tube. Urinary velocity was calculated from dynamic pressure (Pd) with the pitot tube formula and the correcting equation according to the results of the basal experiment. Velocity measured by the pitot tube was proportional to the average velocity in model urethras and the coefficients were determined by diameters of model urethras. We obtained a formula to calculate urinary velocity from the basal experiment. The urinary velocity could be obtained in 32 of 79 patients. Qmax was 8.1 +/- 4.3 mL/s (mean +/- SD; range, 18.4-1.3 mL/s), urethral diameter was 7.3 +/- 3.0 mm (mean +/- SD; range, 18.7-4.3 mm) and urinary velocity was 69.4 +/- 43.6 (mean +/- SD; range, 181.3-0 cm/s) at maximum flow rate. The correlation coefficient of Qmax measured by a flowmeter versus Qdv flow rate calculated with urethral diameter and velocity was 0.41 without significant difference. The use of the pitot tube as an urodynamic catheter to a transrectal ultrasound-guided video urodynamic system can measure urethral pressure, diameter and urinary velocity simultaneously. However, a thinner pitot tube and further clinical trials are needed to obtain more accurate results.

  6. Mathematical Model of Stress-Strain State of Curved Tube of Non-Circular Cross-Section with Account of Technological Wall Thickness Variation

    Science.gov (United States)

    Pirogov, S. P.; Ustinov, N. N.; Smolin, N. I.

    2018-05-01

    A mathematical model of the stress-strain state of a curved tube of a non-circular cross-section is presented, taking into account the technological wall thickness variation. On the basis of the semi-membrane shell theory, a system of linear differential equations describing the deformation of a tube under the effect of pressure is obtained. To solve the boundary value problem, the method of shooting is applied. The adequacy of the proposed mathematical model is verified by comparison with the experimental data and the results of the calculation of tubes by the energy method.

  7. Emergency transfer tube closure and process for sealing transfer tube under emergency conditions

    International Nuclear Information System (INIS)

    Hardin, R.T. Jr.; Marshall, J.R.

    1987-01-01

    In a nuclear fuel reactor well that includes a transfer tube projecting outwardly from wall thereof, the transfer tube is described having a first closure assembly. The transfer tube has a circumferential flange extending outwardly laterally therefrom, an emergency transfer tube closure therefor comprising; a pair of elongated, vertically-extending U-shaped guides, one U-shaped guide disposed laterally on each side of the transfer tube, each of the U-shaped guides comprising a base and laterally extending flanges thereon, the U-shaped guides having their open ends facing each other, a closure plate, having a surface facing the circumferential flange greater in area than the area circumscribed by the outer circumference of the circumferential flange, vertically disposed the U-shaped guides, the closure plate normally being disposed in a vertical plane just slightly in front of the vertical plane of the circumferential flange, two pairs of rollers, one pair of which is rotatably mounted on each side of the closure plate adjacent the U-shaped guides, riding on the inner portion of each of the flanges of each of the U-shaped guides. Each of the U-shaped guides is provided with a pair of spatially disposed openings on a flange thereof adjacent the wall of the nuclear fuel reactor well, each of the pairs of openings being disposed on each of the U-shaped guides a distance equal to the distance between the center lines of the corresponding pair of rollers riding within the U-shaped guides, each of the openings being sufficiently large to receive a corresponding roller of the pairs of rollers in the U-shaped guides. The openings is shaped on the flanges of the U-shaped guides so that when the pairs of rollers are disposed therein, the face of the closure plate will be in sealing engagement with the circumferential flange of the transfer tube

  8. Learning curves for ultrasound guided lung biopsy in the hands of respiratory physicians

    DEFF Research Database (Denmark)

    Laursen, Christian; Naur, Therese Maria Henriette; Bodtger, Uffe

    2016-01-01

    are depicted in figure 1. Six of the physicians had learning curves with a relatively downward or stable projection as a sign of developing competence. Three physicians, however, had learning curves with an upward projection indicating unacceptable competence in performing the procedure......Background: The aim of this study was to determine learning curves for ultrasound guided transthoracic needle biopsies (US-TTNB) performed by respiratory physicians after implementation at three different centers.Methods: During January 2012 to August 2014 patients were included if they had...... a registered US-TTNB procedure at any of the three centers. The US-TTNB was defined as being successful if the result was diagnostic and otherwise as being unsuccessful. Histology or cytology results and clinical follow-up were used as a reference tests. The learning curves for physicians having performed...

  9. Application of guideline for the maintenance of guide tubes

    International Nuclear Information System (INIS)

    Matsubara, Toru

    2009-01-01

    Control Rod Cluster Guide Tubes (GTs) in PWR nuclear plant have the possibility to be worn due to fluid induced vibration of Control Rod Clusters. The maintenance rules for GTs had been established after the discussion with experts, and GTs in Japanese PWR plants have been already maintained in accordance with these maintenance rules. In these rules, the inspection period is decided based on the wear data and the wear progressing prediction with the assumption of constant wear speed. This paper describes the validity of the concepts about maintenance period based on the wear progressing prediction, by using the consecutive inspection data of actual plants. (author)

  10. In the Way of Peacemaker Guide Curve between Water Supply and Flood Control for Short Term Reservoir Operation

    Science.gov (United States)

    Uysal, G.; Sensoy, A.; Yavuz, O.; Sorman, A. A.; Gezgin, T.

    2012-04-01

    Effective management of a controlled reservoir system where it involves multiple and sometimes conflicting objectives is a complex problem especially in real time operations. Yuvacık Dam Reservoir, located in the Marmara region of Turkey, is built to supply annual demand of 142 hm3 water for Kocaeli city requires such a complex management strategy since it has relatively small (51 hm3) effective capacity. On the other hand, the drainage basin is fed by both rainfall and snowmelt since the elevation ranges between 80 - 1548 m. Excessive water must be stored behind the radial gates between February and May in terms of sustainability especially for summer and autumn periods. Moreover, the downstream channel physical conditions constraint the spillway releases up to 100 m3/s although the spillway is large enough to handle major floods. Thus, this situation makes short term release decisions the challenging task. Long term water supply curves, based on historical inflows and annual water demand, are in conflict with flood regulation (control) levels, based on flood attenuation and routing curves, for this reservoir. A guide curve, that is generated using both water supply and flood control of downstream channel, generally corresponds to upper elevation of conservation pool for simulation of a reservoir. However, sometimes current operation necessitates exceeding this target elevation. Since guide curves can be developed as a function of external variables, the water potential of a basin can be an indicator to explain current conditions and decide on the further strategies. Besides, releases with respect to guide curve are managed and restricted by user-defined rules. Although the managers operate the reservoir due to several variable conditions and predictions, still the simulation model using variable guide curve is an urgent need to test alternatives quickly. To that end, using HEC-ResSim, the several variable guide curves are defined to meet the requirements by

  11. Pressure tube reactor

    International Nuclear Information System (INIS)

    Seki, Osamu; Kumasaka, Katsuyuki.

    1988-01-01

    Purpose: To remove the heat of reactor core using a great amount of moderators at the periphery of the reactor core as coolants. Constitution: Heat of a reactor core is removed by disposing a spontaneous recycling cooling device for cooling moderators in a moderator tank, without using additional power driven equipments. That is, a spontaneous recycling cooling device for cooling the moderators in the moderator tank is disposed. Further, the gap between the inner wall of a pressure tube guide pipe disposed through the vertical direction of a moderator tank and the outer wall of a pressure tube inserted through the guide pipe is made smaller than the rupture distortion caused by the thermal expansion upon overheating of the pressure tube and greater than the minimum gap required for heat shiels between the pressure tube and the pressure tube guide pipe during usual operation. In this way, even if such an accident as can not using a coolant cooling device comprising power driven equipment should occur in the pressure tube type reactor, the rise in the temperature of the reactor core can be retarded to obtain a margin with time. (Kamimura, M.)

  12. An Analysis of the Guided Wave Patterns in a Small-bore Titanium Tube by a Magnetostrictive Sensor Technique

    International Nuclear Information System (INIS)

    Cheong, Yong-Moo; Kim, Shin

    2007-01-01

    The presence of damage or defects in pipes or tubes is one of the major problems in nuclear power plants. However, in many cases, it is difficult to inspect all of them by the conventional ultrasonic methods, because of their geometrical complexity and inaccessibility. The magnetostrictive guided wave technique has several advantages for practical applications, such as a 100- percent volumetric coverage of a long segment of a structure, a reduced inspection time and its cost effectiveness, as well as its' relatively simple structure. One promising feature of the magnetostrictive sensor technique is that the wave patterns are relatively clear and simple compared to the conventional piezoelectric ultrasonic transducer. If we can characterize the evolution of the defect signals, it can be a promising tool for a structural health monitoring of pipes for a long period as well as the identification of flaws. An in-bore guided wave probe was developed for an application to small bore heat exchanger tubes. The magnetostrictive probe installed on the hollow cylindrical waveguide generates and detects torsional waves in the waveguide. This waveguide is expanded by the draw bar to create an intimate mechanical contact between the waveguide and the inside surface of the tube being tested. In this paper, we analyzed the wave patterns reflected from various artificial holes in a titanium tube, which is used in the condenser in a nuclear power plant. The torsional guided waves were generated and received by a coil and a DC magnetized nickel strip as well as an inbore guided wave probe. The wave patterns from various defects were compared with two different sensor techniques and a detectable limit of the defected was estimated

  13. Wear plates control rod guide tubes top internal reactor vessel C. N. VANDELLOS II; Desgaste placas tubos guia barras de control interno superior vasija del reactor C.N. Vandellos II

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The guide tubes for control rods forming part of the upper internals of the reactor vessel, its function is to guide the control rod to permit its insertion in the reactor core. These guide tubes are suspended from the upper support plate which are fixed by bolts and extending to the upper core plate which is fastened by clamping bolts (split pin) to prevent lateral displacement of the guide tubes, while allowing axial expansion.

  14. Primary water stress corrosion cracking resistance of alloy X-750 for guide tube support pins

    International Nuclear Information System (INIS)

    Yonezawa, T.; Onimura, K.; Yonehana, M.; Fujitani, T.

    1990-01-01

    The authors have developed the maintenance free guide tube support pins for PWR, and conducted the three kinds of long time stress corrosion cracking tests in high temperature water, in order to verify the reliability of the maintenance free guide tube support pins. This paper describes the features of our maintenance free support pins and the results of long time stress corrosion cracking test for the maintenance free support pins. After exposure at 320 0 C in the simulated primary water of PWR for about 35,000 hours or at 360 0 C in the same chemistry water as the primary water for about 24,900 hours, no abnormal indication such as cracks was observed in all test support pins exposed 320 0 C and 360 0 C primary water, by ultrasonic inspection, and liquid penetrate test. From the above, it seems that our maintenance free support pins are keepable the soundness up to the end of plant life, in PWR plants

  15. Initial Experience with Computed Tomography and Fluoroscopically Guided Placement of Push-Type Gastrostomy Tubes Using a Rupture-Free Balloon Catheter

    International Nuclear Information System (INIS)

    Fujita, Takeshi; Tanabe, Masahiro; Yamatogi, Shigenari; Shimizu, Kensaku; Matsunaga, Naofumi

    2011-01-01

    The purpose of this study was to evaluate the safety and feasibility of percutaneous radiologic gastrostomy placement of push-type gastrostomy tubes using a rupture-free balloon (RFB) catheter under computed tomography (CT) and fluoroscopic guidance. A total of 35 patients (23 men and 12 women; age range 57–93 years [mean 71.7]) underwent percutaneous CT and fluoroscopically guided gastrostomy placement of a push-type gastrostomy tube using an RFB catheter between April 2005 and July 2008. Technical success, procedure duration, and complications were analyzed. Percutaneous radiologic gastrostomy placement was considered technically successful in all patients. The median procedure time was 39 ± 13 (SD) min (range 24–78). The average follow-up time interval was 103 days (range 7–812). No major complications related to the procedure were encountered. No tubes failed because of blockage, and neither tube dislodgement nor intraperitoneal leakage occurred during the follow-up period. The investigators conclude that percutaneous CT and fluoroscopically guided gastrostomy placement with push-type tubes using an RFB catheter is a safe and effective means of gastric feeding when performed by radiologists.

  16. Fluoroscopically Guided Transcervical Fallopian Tube Recanalization of Post-Sterilization Reversal Mid-Tubal Obstructions

    International Nuclear Information System (INIS)

    Houston, J. Graeme; Anderson, David; Mills, John; Harrold, Anthony

    2000-01-01

    Purpose: To assess the technical success and early outcome of fluoroscopically guided transcervical fallopian tube recanalization (FTR) in mid-tubal occlusion following sterilization reversal surgery.Methods: From July 1995 to January 1998, patients with greater than 12 months secondary infertility underwent hysterosalpingography (HSG). FTR was performed in proximal or mid-tubal occlusion. Cases of FTR in mid-tubal occlusion were included in this study. Technical success (defined as complete tubal patency) using a standard guidewire and hydrophilic glidewire, the number of patients with at least one patent tube, and the intrauterine and ectopic pregnancy rates were determined.Results: Twenty-six infertile patients with previous sterilization reversal underwent HSG. Eight of 26 (31%) patients (mean age 32 years, range 23-37 years), had attempted FTR for mid-tubal occlusion at the site of surgical anastomosis. Fourteen tubes were attempted as there were two previous salpingectomies. Technical success was achieved in eight of 14 (57%) tubes attempted, resulting in five of eight (62%) patients having at least one patent tube. At follow-up (mean 18 months, range 12-28 months) in these five patients there was one intrauterine pregnancy. There were no ectopic pregnancies.Conclusions: FTR in mid-tubal obstruction in infertile patients following sterilization reversal surgery is technically feasible and may result in intrauterine pregnancy. In this small group there was a lower technical success rate and lower pregnancy rate than in unselected proximal tubal occlusion

  17. Experimental Observation of Cumulative Second-Harmonic Generation of Circumferential Guided Wave Propagation in a Circular Tube

    International Nuclear Information System (INIS)

    Deng Ming-Xi; Gao Guang-Jian; Li Ming-Liang

    2015-01-01

    The experimental observation of cumulative second-harmonic generation of the primary circumferential guided wave propagation is reported. A pair of wedge transducers is used to generate the primary circumferential guided wave desired and to detect its fundamental-frequency and second-harmonic amplitudes on the outside surface of the circular tube. The amplitudes of the fundamental waves and the second harmonics of the circumferential guided wave propagation are measured for different separations between the two wedge transducers. At the driving frequency where the primary and the double-frequency circumferential guided waves have the same linear phase velocities, the clear second-harmonic signals can be observed. The quantitative relationships between the second-harmonic amplitudes and circumferential angle are analyzed. It is experimentally verified that the second harmonics of primary circumferential guided waves do have a cumulative growth effect with the circumferential angle. (paper)

  18. The writhe of open and closed curves

    International Nuclear Information System (INIS)

    Berger, Mitchell A; Prior, Chris

    2006-01-01

    Twist and writhe measure basic geometric properties of a ribbon or tube. While these measures have applications in molecular biology, materials science, fluid mechanics and astrophysics, they are under-utilized because they are often considered difficult to compute. In addition, many applications involve curves with endpoints (open curves); but for these curves the definition of writhe can be ambiguous. This paper provides simple expressions for the writhe of closed curves, and provides a new definition of writhe for open curves. The open curve definition is especially appropriate when the curve is anchored at endpoints on a plane or stretches between two parallel planes. This definition can be especially useful for magnetic flux tubes in the solar atmosphere, and for isotropic rods with ends fixed to a plane

  19. Guide tube support pin experience at Ringhals plant, Sweden

    International Nuclear Information System (INIS)

    Ericsson, E.

    1984-01-01

    The intention with my presentation is to give an information about how we finally made the decision to make the replacement of Guide Tube Support Pin (GTSP) on unit 3 and how it was done. At the Ringhals Plant in Sweden, there are four units of which three are Westinghouse 3-loop PWR:s. One unit is an ASEA-ATOM BWR. Mainly due to climate reasons with a long and cold winter and switching to electrical heating in Swedish housing, a demand for highest possible availability of electrical power supply during the winter season has become a necessity. Therefore all refueling/maintenance outages for the nuclear units in Sweden are scheduled during the summer months, when also all recognized risks for disturbances during the following operation period have to be eliminated

  20. Engineering analysis of ITER In-Vessel Viewing System guide tube

    Energy Technology Data Exchange (ETDEWEB)

    Casal, Natalia, E-mail: natalia.casal@iter.org [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France); Bates, Philip [Fusion for Energy, Barcelona (Spain); Bede, Ottó [Oxford Technologies Ltd., Abingdon (United Kingdom); Damiani, Carlo; Dubus, Gregory [Fusion for Energy, Barcelona (Spain); Omran, Hassan [Oxford Technologies Ltd., Abingdon (United Kingdom); Palmer, Jim [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France); Puiu, Adrian [Fusion for Energy, Barcelona (Spain); Reichle, Roger; Suárez, Alejandro; Walker, Christopher; Walsh, Michael [ITER Organization, Route de Vinon sur Verdon, St Paul-lez-Durance (France)

    2015-10-15

    Highlights: • Conceptual design of IVVS Loads action on IVVS Dominant loads. • Seismic and baking conditions. • No active cooling needed for IVVS. • IVVS requires additional support points to avoid excessive deformation. - Abstract: The In Vessel Viewing System (IVVS) will be one of the essential machine diagnostic systems at ITER to provide information about the status of in-vessel and plasma facing components and to evaluate the dust inside the Vacuum Vessel. The current design consists of six scanning probes and their deployment systems, which are placed in dedicated ports at the divertor level. These units are located in resident guiding tubes 10 m long, which allow the IVVS probes to go from their storage location to the scanning position by means of a simple straight translation. Moreover, each resident tube is supported inside the corresponding Vacuum Vessel and Cryostat port extensions, which are part of the primary confinement barrier. As the Vacuum Vessel and the Cryostat will move with respect to each other during operation (especially during baking) and during incidents and accidents (disruptions, vertical displacement events, seismic events), the structural integrity of the resident tube and the surrounding vacuum boundaries would be compromised if the required flexibility and supports are not appropriately assured. This paper focuses on the integration of the present design of the IVVS into the Vacuum Vessel and Cryostat environment. It presents the adopted strategy to withstand all the main interfacing loads without damaging the confinement barriers and the corresponding analysis supporting it.

  1. Fluoroscopy-guided insertion of nasojejunal tubes in children - setting local diagnostic reference levels

    International Nuclear Information System (INIS)

    Vitta, Lavanya; Raghavan, Ashok; Sprigg, Alan; Morrell, Rachel

    2009-01-01

    Little is known about the radiation burden from fluoroscopy-guided insertions of nasojejunal tubes (NJTs) in children. There are no recommended or published standards of diagnostic reference levels (DRLs) available. To establish reference dose area product (DAP) levels for the fluoroscopy-guided insertion of nasojejunal tubes as a basis for setting DRLs for children. In addition, we wanted to assess our local practice and determine the success and complication rates associated with this procedure. Children who had NJT insertion procedures were identified retrospectively from the fluoroscopy database. The age of the child at the time of the procedure, DAP, screening time, outcome of the procedure, and any complications were recorded for each procedure. As the radiation dose depends on the size of the child, the children were assigned to three different age groups. The sample size, mean, median and third-quartile DAPs were calculated for each group. The third-quartile values were used to establish the DRLs. Of 186 procedures performed, 172 were successful on the first attempt. These were performed in a total of 43 children with 60% having multiple insertions over time. The third-quartile DAPs were as follows for each age group: 0-12 months, 2.6 cGy cm 2 ; 1-7 years, 2.45 cGy cm 2 ; >8 years, 14.6 cGy cm 2 . High DAP readings were obtained in the 0-12 months (n = 4) and >8 years (n = 2) age groups. No immediate complications were recorded. Fluoroscopy-guided insertion of NJTs is a highly successful procedure in a selected population of children and is associated with a low complication rate. The radiation dose per procedure is relatively low. (orig.)

  2. A method for the measurement of dispersion curves of circumferential guided waves radiating from curved shells: experimental validation and application to a femoral neck mimicking phantom

    Science.gov (United States)

    Nauleau, Pierre; Minonzio, Jean-Gabriel; Chekroun, Mathieu; Cassereau, Didier; Laugier, Pascal; Prada, Claire; Grimal, Quentin

    2016-07-01

    Our long-term goal is to develop an ultrasonic method to characterize the thickness, stiffness and porosity of the cortical shell of the femoral neck, which could enhance hip fracture risk prediction. To this purpose, we proposed to adapt a technique based on the measurement of guided waves. We previously evidenced the feasibility of measuring circumferential guided waves in a bone-mimicking phantom of a circular cross-section of even thickness. The goal of this study is to investigate the impact of the complex geometry of the femoral neck on the measurement of guided waves. Two phantoms of an elliptical cross-section and one phantom of a realistic cross-section were investigated. A 128-element array was used to record the inter-element response matrix of these waveguides. This experiment was simulated using a custom-made hybrid code. The response matrices were analyzed using a technique based on the physics of wave propagation. This method yields portions of dispersion curves of the waveguides which were compared to reference dispersion curves. For the elliptical phantoms, three portions of dispersion curves were determined with a good agreement between experiment, simulation and theory. The method was thus validated. The characteristic dimensions of the shell were found to influence the identification of the circumferential wave signals. The method was then applied to the signals backscattered by the superior half of constant thickness of the realistic phantom. A cut-off frequency and some portions of modes were measured, with a good agreement with the theoretical curves of a plate waveguide. We also observed that the method cannot be applied directly to the signals backscattered by the lower half of varying thicknesses of the phantom. The proposed approach could then be considered to evaluate the properties of the superior part of the femoral neck, which is known to be a clinically relevant site.

  3. Magnetization curves of sintered heavy tungsten alloys for applications in MRI-guided radiotherapy

    International Nuclear Information System (INIS)

    Kolling, Stefan; Oborn, Bradley M.; Keall, Paul J.; Horvat, Joseph

    2014-01-01

    Purpose: Due to the current interest in MRI-guided radiotherapy, the magnetic properties of the materials commonly used in radiotherapy are becoming increasingly important. In this paper, measurement results for the magnetization (BH) curves of a range of sintered heavy tungsten alloys used in radiation shielding and collimation are presented. Methods: Sintered heavy tungsten alloys typically contain >90 % tungsten and 0 and the BH curve derived. Results: The iron content of the alloys was found to play a dominant role, directly influencing the magnetizationM and thus the nonlinearity of the BH curve. Generally, the saturation magnetization increased with increasing iron content of the alloy. Furthermore, no measurable magnetization was found for all alloys without iron content, despite containing up to 6% of nickel. For two samples from different manufacturers but with identical quoted nominal elemental composition (95% W, 3.5% Ni, 1.5% Fe), a relative difference in the magnetization of 11%–16% was measured. Conclusions: The measured curves show that the magnetic properties of sintered heavy tungsten alloys strongly depend on the iron content, whereas the addition of nickel in the absence of iron led to no measurable effect. Since a difference in the BH curves for two samples with identical quoted nominal composition from different manufacturers was observed, measuring of the BH curve for each individual batch of heavy tungsten alloys is advisable whenever accurate knowledge of the magnetic properties is crucial. The obtained BH curves can be used in FEM simulations to predict the magnetic impact of sintered heavy tungsten alloys

  4. Monitoring of Soft Deposition Layers in Liquid-Filled Tubes with Guided Acoustic Waves Excited by Clamp-on Transducers.

    Science.gov (United States)

    Tietze, Sabrina; Singer, Ferdinand; Lasota, Sandra; Ebert, Sandra; Landskron, Johannes; Schwuchow, Katrin; Drese, Klaus Stefan; Lindner, Gerhard

    2018-02-09

    The monitoring of liquid-filled tubes with respect to the formation of soft deposition layers such as biofilms on the inner walls calls for non-invasive and long-term stable sensors, which can be attached to existing pipe structures. For this task a method is developed, which uses an ultrasonic clamp-on device. This method is based on the impact of such deposition layers on the propagation of circumferential guided waves on the pipe wall. Such waves are partly converted into longitudinal compressional waves in the liquid, which are back-converted to guided waves in a circular cross section of the pipe. Validating this approach, laboratory experiments with gelatin deposition layers on steel tubes exhibited a distinguishable sensitivity of both wave branches with respect to the thickness of such layers. This allows the monitoring of the layer growth.

  5. Development and Evaluation of a Novel Curved Biopsy Device for CT-Guided Biopsy of Lesions Unreachable Using Standard Straight Needle Trajectories

    Energy Technology Data Exchange (ETDEWEB)

    Schulze-Hagen, Maximilian Franz, E-mail: mschulze@ukaachen.de; Pfeffer, Jochen; Zimmermann, Markus; Liebl, Martin [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany); Stillfried, Saskia Freifrau von [University Hospital RWTH Aachen, Department of Pathology (Germany); Kuhl, Christiane; Bruners, Philipp; Isfort, Peter [University Hospital RWTH Aachen, Department of Diagnostic and Interventional Radiology (Germany)

    2017-06-15

    PurposeTo evaluate the feasibility of a novel curved CT-guided biopsy needle prototype with shape memory to access otherwise not accessible biopsy targets.Methods and MaterialsA biopsy needle curved by 90° with specific radius was designed. It was manufactured using nitinol to acquire shape memory, encased in a straight guiding trocar to be driven out for access of otherwise inaccessible targets. Fifty CT-guided punctures were conducted in a biopsy phantom and 10 CT-guided punctures in a swine corpse. Biposies from porcine liver and muscle tissue were separately gained using the biopsy device, and histological examination was performed subsequently.ResultsMean time for placement of the trocar and deployment of the inner biopsy needle was ~205 ± 69 and ~93 ± 58 s, respectively, with a mean of ~4.5 ± 1.3 steps to reach adequate biopsy position. Mean distance from the tip of the needle to the target was ~0.7 ± 0.8 mm. CT-guided punctures in the swine corpse took relatively longer and required more biopsy steps (~574 ± 107 and ~380 ± 148 s, 8 ± 2.6 steps). Histology demonstrated appropriate tissue samples in nine out of ten cases (90%).ConclusionsTargets that were otherwise inaccessible via standard straight needle trajectories could be successfully reached with the curved biopsy needle prototype. Shape memory and preformed size with specific radius of the curved needle simplify the target accessibility with a low risk of injuring adjacent structures.

  6. A Method to Establishing Tube Plugging Criterion for Heat Exchangers with Straight Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyungnam [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    The difference of thermal expansion coefficients between the shell and tube materials causes the stress in axial direction of tube. Because of the axial stress due to thermal load, the straight tubes are used for heat exchangers operated in low temperature such as CCW (Component Cooling Water) heat exchangers and condensers. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. A method to establish the tube plugging criteria of heat exchangers with straight tubes are introduced based on the USNRC Regulatory Guide 1.121. As an example, the tube plugging criterion for the CCW heat exchanger of a nuclear power plant is provided.

  7. Three-finger tracheal palpation to guide endotracheal tube depth in children.

    Science.gov (United States)

    Gamble, Jonathan J; McKay, William P; Wang, Andrew F; Yip, Kinsha A; O'Brien, Jennifer M; Plewes, Christopher E

    2014-10-01

    Accurate endotracheal tube (ETT) depth is critical, especially in children. The current tools used to guide appropriate ETT depth have significant limitations. To evaluate the utility of tracheal palpation in the neck to guide appropriate ETT placement in children. A prospective observational study with a convenience sample of 50 children was conducted. During intubation, an investigator palpated the trachea with three fingertips side-by-side extending upward from the suprasternal notch. The anesthesiologist advanced the ETT slowly until palpated at the sternal notch. The investigator stated ETT palpation certainty as 'strongly felt', 'weakly felt', or 'not felt.' Final ETT position was determined by bronchoscopy and categorized as 'ETT too shallow' (tip in proximal ¼ of trachea), 'ETT too deep' (tip in distal ¼ of trachea), or 'ETT placement satisfactory' (between those extremes). Thirty boys and 20 girls undergoing dental surgery with nasal intubation were recruited (median age 4.4 years; range 2.0-10.8). The ETT (all ≥4 mm ID) was palpable at the sternal notch in all patients: 46 of 50 strongly palpable and 4 of 50 weakly palpable. The experimental methods led to satisfactory ETT placement in 49 of 50 patients, too deep in 1 of 50 patients. Compared with the Pediatrics Advanced Life Support (PALS) predictive formula, satisfactory placement would have been 41 of 50 patients (P guide ETT placement has excellent clinical performance and better guides appropriate ETT depth than the PALS formula in our study population. © 2014 John Wiley & Sons Ltd.

  8. Flow mixing inside a control-rod guide tube – Experimental tests and CFD simulations

    International Nuclear Information System (INIS)

    Angele, Kristian; Odemark, Ylva; Cehlin, Mathias; Hemström, Bengt; Högström, Carl-Maikel; Henriksson, Mats; Tinoco, Hernan; Lindqvist, Hans

    2011-01-01

    This paper covers a combined experimental and computational effort carried out at Vattenfall Research and Development AB in order to study the thermal mixing in the annular region between a top tube and a control-rod stem. The low frequency thermal fluctuations in this region can result in problems with thermal fatigue and have caused cracks in the control-rod stems of several nuclear reactors (). The flow in the vertical annular region formed by the top tube and the control-rod stem is characterized by the mixing of hot bypass flow with cold crud-removal flow. The crud-removal flow is flowing upwards along the control-rod stem, and the warmer bypass flow is entering through eight horizontal holes positioned in the lower part of the guide tube and four holes in the upper part of the top tube, forming jets. Two full-scale models of a control rod, including the control-rod stem and the guide tube, were constructed. The first model, designed to work at atmospheric conditions, was made of Plexiglass, in order to be able to visualize the mixing process, whereas the second one was made of steel to allow for a higher temperature difference between the two flows, and the heating of the top tube. CFD simulations of the case at atmospheric conditions were also carried out. Both the experiments and the simulations showed that the mixing region between the cold crud-removal flow and the warm bypass flow is dominated by large flow structures coming from above. The process is characterized by low frequency, high amplitude temperature fluctuations. The process is basically hydrodynamic, caused by the downward transport of flow structures originated at the upper bypass inlets. The damping thermal effects through buoyancy is of secondary importance, as also the scaling analysis shows, however a slight damping of the temperature fluctuations can be seen due to natural convection due to a pre-heating of the cold crud-removal flow. The comparison between numerical and experimental

  9. Simulated experimental research on flow field near control rod guide tubes

    International Nuclear Information System (INIS)

    Yu Ping'an; Shen Xiuzhong; Yang Guanyue; He Fangzheng; Gao Weiguo; Zhang Zhiyi; Tian Ji'an

    1997-01-01

    The paper presents the velocity measurement in the 1/4 scale transparent model of PWR pressure vessel upper plenum of 300 MW nuclear power plant by employing dynamic resistance strain foil velocity measurement technology and laser Doppler velocity measurement technology which have no effect on the flow field. In the experiment water is chosen as the fluid. As a result of the measurement the hydraulic load on the control rods is clarified and the experimental basis is provided for the analysis of whether the control rods are moving upward and downward freely and drop rapidly in emergency case by order. Meantime it also provides the experimental basis for the optical design of the control rod guide tubes and bundles

  10. Development and Technology Transfer of the Syncro Blue Tube (Gabriel) Magnetically Guided Feeding Tube

    Science.gov (United States)

    2017-06-01

    suggestions for reducing this burden to Department of Defense, Washington Headquarters Services, Directorate for Information Operations and Reports (0704-0188...the tube to the 110 cm mark. At the 110 cm mark, secure the tube with medical tape and remove the stylet completely allowing enough tube slack ...and it provides slack that allows tube to advance distally by the effect of natural peristalsis on the bolus-sized balloon. Results: Most feeding

  11. Study of creep collapse of tubes subject to external pressure at elevated temperature

    International Nuclear Information System (INIS)

    Takikawa, N.

    1982-01-01

    Intermediate heat exchanger (IHX) tubes of VHTR form the boundary between the primary and secondary coolants of the reactor. The tubes are subject to external pressures at a postulated secondary coolant depressurization accident, which might lead to creep collapse. Therefore, it is necessary to ensure the integrity against creep collapse by analysis. The objective of this work is to study a simplified analytical method for predicting collapse time of a curved tube subjected to an external pressure. The study is made based on the comparison of experimental collapse time of curved and straight tubes. Creep collapse tests were conducted under an elevated temperature and an external pressure. Test results showed that curved tubes had longer collapse time than straight tubes with the same cross sectional ovality. The simplified analytical method for a curved tube is proposed in this report, which is to compute collapse time of a straight tube with the same ovality. And in this method the computed time is considered as collapse time of the curved tube. The above test results show that this simplified method gives the conservative collapse time. And it is confirmed by additional IHX tube tests that the method is applicable to creep collapse analysis of IHX tubes

  12. Nuclear reactor internals with control elements guides

    International Nuclear Information System (INIS)

    Baujat, J.; Chevereau, G.

    1991-01-01

    The internals have a lower plate, a superior plate, support columns and guide tubes for the control rods displacements. The lower section of the control rod guide tube have a base that fits into a bevelled seat in the lower plate. The guide tube is held into the seat by a spring, compressed between the base of the upper section of the tube and the lower plate

  13. Dealing with control rod guide tube support pin cracking in French PWRs

    International Nuclear Information System (INIS)

    Guicherd, L.

    1984-01-01

    Cracking and failure of control rod guide tube support pins has been encountered at a number of PWRs around the world. To deal with the problem, the French embarked on an extremely ambitious backfitting programme, involving the installation of replacement pins at all their operating 900MWe units. This highly successful programme, which will be completed in 1985, has been carried out with very low occupational doses and, in the last two years, has required no extensions to annual refuelling outage periods at the plants concerned. The French approach has involved a number of innovations, which should be of considerable interest to other PWR owners worldwide. (author)

  14. Changes in the design, fabrication and setting of guide tube support pins in alloy X750

    International Nuclear Information System (INIS)

    Benhamou, C.; Chambrin, J.L.; Todeschini, P.; Champredonde, J.; Lemaire, E.

    2004-01-01

    As a consequence of a problem of stress corrosion cracking (SCC) encountered on guide tube support pins (GTSP) of first generation (1982) and of second generation (1987), EDF and Framatome decided in mars 1988 to launch an important program involving a complete overhaul of the design, the material used, the fabrication and the setting in reactor of GTSP. This program has led to the implementation in 900 MWe and 1300 MWe PWR of a new tube guide support pin called NG89. This implementation began in 1989, now 15 years later, 40% of the operating GTSP in 900 MWe and 1300 MWe PWR are of NG89 type, the oldest ones cumulate 105000 hours in service without negative feedback experience. The main features of the NG89 is: - to be made from an alloy X-750 containing boron (from 25 to 45 ppm) - to have a SCC threshold set at 720 MPa - to be machined from metal bars completely treated, - to have a rolling of the fillets, and - to undergo a shot blasting on the zones of the surface the most acted upon. (A.C.)

  15. A Novel Device for Accurate Chest Tube Insertion

    DEFF Research Database (Denmark)

    Katballe, Niels; Moeller, Lars B; Olesen, Winnie H

    2016-01-01

    BACKGROUND: Optimal positioning of a large-bore chest tube is in the part of the pleural cavity that needs drainage. It is recommended that the chest tube be positioned apically in pneumothorax and basally for fluids. However, targeted chest tube positioning to a specific part of the pleural cavity...... can be a challenge. METHODS: A new medical device, the KatGuide, was developed for accurate guiding of a chest tube (28F) to an intended part of the pleural cavity. The primary end point of this randomized, controlled trial was optimal position of the chest tube. The optimal position in pneumothorax...

  16. Reactor scram device using fluid poison tubes

    International Nuclear Information System (INIS)

    Iwasaki, Toshio; Hasegawa, Koji.

    1979-01-01

    Purpose: To improve the response function in the reactor scram with no wide space by injecting poisons in soluble poison guide tubes to such a liquid level as giving no effect on usual reactor operation. Constitution: Soluble poison guide tubes in a reactor are connected at their upper ends to a buffer tank and at their lower ends to a pressurizer by way of a header and an injection valve. The header is connected by way of a valve with a level meter, one end of which is connected to the buffer tank. During reactor operation, the injection valve is closed and the soluble poisons in the pressurizer vessel is maintained at a pressurized state and, while on the other hand, soluble poisons are injected by way of the header to the lower end of the soluble poison guide tubes by the opening of a valve, which is thereafter closed. Upon scram, a valve is closed to protect the level meter and pressurized poisons are rapidly filled in the guide tubes by the release of the injection valve. (Kawakami, Y.)

  17. Status on the selection and development of an embrittlement trend curve to use in ASTM standard guide E900

    International Nuclear Information System (INIS)

    Kirk, M.; Brian Hall, J.; Server, W.; Lucon, E.; Erickson, M.; Stoller, R.

    2015-01-01

    ASTM E900-07, Standard Guide for Predicting Radiation-Induced Transition Temperature Shift in Reactor Vessel Materials, includes an embrittlement trend curve. The trend curve can be used to predict the effect of neutron irradiation on the embrittlement of ferritic pressure vessel steels, as quantified by the shift in the Charpy V-Notch transition curve at 41 Joules of absorbed energy (ΔT 41J ). The current E900 trend curve was first adopted in the 2002 revision. In 2011 ASTM Subcommittee E10.02 undertook an extensive effort to evaluate the adequacy of the E900 trend curve for continued use. This paper summarizes the current status of this effort, which has produced a trend curve calibrated using a database of over 1800 ΔT 41J values from the light water reactor surveillance programs in thirteen countries. (authors)

  18. Models for Automated Tube Performance Calculations

    International Nuclear Information System (INIS)

    Brunkhorst, C.

    2002-01-01

    High power radio-frequency systems, as typically used in fusion research devices, utilize vacuum tubes. Evaluation of vacuum tube performance involves data taken from tube operating curves. The acquisition of data from such graphical sources is a tedious process. A simple modeling method is presented that will provide values of tube currents for a given set of element voltages. These models may be used as subroutines in iterative solutions of amplifier operating conditions for a specific loading impedance

  19. Concentric Tube Robot Design and Optimization Based on Task and Anatomical Constraints

    Science.gov (United States)

    Bergeles, Christos; Gosline, Andrew H.; Vasilyev, Nikolay V.; Codd, Patrick J.; del Nido, Pedro J.; Dupont, Pierre E.

    2015-01-01

    Concentric tube robots are catheter-sized continuum robots that are well suited for minimally invasive surgery inside confined body cavities. These robots are constructed from sets of pre-curved superelastic tubes and are capable of assuming complex 3D curves. The family of 3D curves that the robot can assume depends on the number, curvatures, lengths and stiffnesses of the tubes in its tube set. The robot design problem involves solving for a tube set that will produce the family of curves necessary to perform a surgical procedure. At a minimum, these curves must enable the robot to smoothly extend into the body and to manipulate tools over the desired surgical workspace while respecting anatomical constraints. This paper introduces an optimization framework that utilizes procedureor patient-specific image-based anatomical models along with surgical workspace requirements to generate robot tube set designs. The algorithm searches for designs that minimize robot length and curvature and for which all paths required for the procedure consist of stable robot configurations. Two mechanics-based kinematic models are used. Initial designs are sought using a model assuming torsional rigidity. These designs are then refined using a torsionally-compliant model. The approach is illustrated with clinically relevant examples from neurosurgery and intracardiac surgery. PMID:26380575

  20. Guide device

    International Nuclear Information System (INIS)

    Brammer, C.M. Jr.

    1977-01-01

    Disclosed is a fuel handling guide tube centering device for use in nuclear reactors during fuel assembly handling operations. The device comprises an outer ring secured to the flange of a nuclear reactor pressure vessel, a rotatable table rotatably coupled to the outer ring, and a plurality of openings through the table. Truncated locating cones are positioned in each of the openings in the table, and the locating cones center the guide tube during fuel handling operations. The openings in the table are located such that each fuel assembly in the nuclear core may be aligned with one of the openings by a suitable rotation of the table. The locating cones thereby provide alignment between the fuel handling mechanism located in the guide tube and the individual fuel assemblies of the cone. The need for a device to provide alignment is especially critical for floating nuclear power plants, where wave motion may exist during fuel handling operations. 5 claims, 4 figures

  1. Focusing and guiding intense electron beams by a superconductor tube

    International Nuclear Information System (INIS)

    Roth, P.

    1996-01-01

    An intense electron beam travelling axially through the opening of a superconductor tube was studied. Model calculations showed that the beam is focused by the superconductor tube when the space-charge effect of the beam electrons is compensated. The tube functions as a lens for electrons injected parallel to the tube axis and also for electrons having a small initial radial velocity component. The electron trajectories were computed, and the focal length of the superconductor tube was estimated. (author). 2 figs., 6 refs

  2. Focusing and guiding intense electron beams by a superconductor tube

    Energy Technology Data Exchange (ETDEWEB)

    Roth, P

    1997-12-31

    An intense electron beam travelling axially through the opening of a superconductor tube was studied. Model calculations showed that the beam is focused by the superconductor tube when the space-charge effect of the beam electrons is compensated. The tube functions as a lens for electrons injected parallel to the tube axis and also for electrons having a small initial radial velocity component. The electron trajectories were computed, and the focal length of the superconductor tube was estimated. (author). 2 figs., 6 refs.

  3. Device for the selective positioning of a component on a tube plate

    International Nuclear Information System (INIS)

    1974-01-01

    The invention relates to a device for the selective positioning of a component on a tube plate. It particularly applies to the positioning of a guide tube head successively opposite all the tubes of the tube bundle of a nuclear reactor steam generator. The large number of tubes in the tube bundle of the steam generator in a pressure water nuclear power station must be checked periodically for any likely corrosion. This check is effected with a Foucault current probe which is inserted in each tube in turn and is connected to a probe signal processing unit. The probe is placed in a flexible guide tube brought in turn in front of each tube of the bundle to be checked. The invention concerns a device to move the opening of a tube guide for a Foucault current detector over the entire surface of the tube plate, thereby providing access to all the tubes whilst limiting the interventions to a single positioning and a single withdrawal of the apparatus for testing all the bundle. Between the two interventions at the beginning and end of the operation, all displacements are remote controlled from outside the dangerous radioacive area [fr

  4. PWR steam generator tubing sample library

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    In order to compile the tubing sample library, two approaches were employed: (a) tubing sample replication by either chemical or mechanical means, based on field tube data and metallography reports for tubes already destructively examined; and (b) acquisition of field tubes removed from operating or retired steam generators. In addition, a unique mercury modeling concept is in use to guide the selection of replica samples. A compendium was compiled that summarizes field observations and morphologies of steam generator tube degradation types based on available NDE, destructive examinations, and field reports. This compendium was used in selecting candidate degradation types that were manufactured for inclusion in the tube library

  5. Source Terms for HFIR Beam Tube Shielding Analyses, and a Complete Shielding Analysis of the HB-3 Tube

    International Nuclear Information System (INIS)

    Bucholz, J.A.

    2000-01-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory is in the midst of a massive upgrade program to enhance experimental facilities. The reactor presently has four horizontal experimental beam tubes, all of which will be replaced or redesigned. The HB-2 beam tube will be enlarged to support more guide tubes, while the HB-4 beam tube will soon include a cold neutron source

  6. Source Terms for HFIR Beam Tube Shielding Analyses, and a Complete Shielding Analysis of the HB-3 Tube

    Energy Technology Data Exchange (ETDEWEB)

    Bucholz, J.A.

    2000-07-01

    The High Flux Isotope Reactor (HFIR) at the Oak Ridge National Laboratory is in the midst of a massive upgrade program to enhance experimental facilities. The reactor presently has four horizontal experimental beam tubes, all of which will be replaced or redesigned. The HB-2 beam tube will be enlarged to support more guide tubes, while the HB-4 beam tube will soon include a cold neutron source.

  7. Fluoroscopic-guided primary single-step percutaneous gastrostomy. Initial results using the Freka {sup registered} GastroTube; Primaere einzeitige durchleuchtungsgesteuerte perkutane Gastrostomie (PG). Erste Ergebnisse mit dem Freka {sup registered} GastroTube

    Energy Technology Data Exchange (ETDEWEB)

    Hahne, J.D.; Schoennagel, B.P.; Arndt, C.; Bannas, P.; Koops, A.; Adam, G.; Habermann, C.R. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Herrmann, J. [Universitaetsklinikum Hamburg-Eppendorf (Germany). Zentrum fuer Radiologie; Universitaetsklinikum Hamburg-Eppendorf (Germany). Abt. Paediatrische Radiologie

    2011-07-15

    Purpose: To determine the practicability and outcome of fluoroscopic-guided primary one-step treatment of percutaneous gastrostomy (PG) with the system Freka {sup registered} Gastro Tube (Fresenius Kabi, Germany). Materials and Methods: In 39 patients (mean age 62.7 {+-} 12.0 years), primary PG was performed based on clinical indication from August 2009 to April 2010. The intervention was performed by an experienced radiologist under aseptic conditions by direct puncture with Freka {sup registered} Gastro Tube under fluoroscopic guidance. The clinical data and outcome as well as any complications originated from the electronic archive of the University Medical Center Hamburg-Eppendorf. Results: The intervention was technically successful in all 39 patients. Within the mean follow-up time of 155.3 {+-} 73.6 days, 29 patients (74.4 %) did not experience complications. 10 patients (25.6 %) had to be revised. Complications manifested after a mean of 135.6 {+-} 61.2 days and mainly corresponded to accidental dislocation (50 %). One patient had to be surgically revised under suspicion of a malpositioned tube and suspected intestinal perforation. Clinically relevant wound infections were not detected. The total costs per patient were 553.17 Euro for our single-step treatment (OPS 5 - 431.x) vs. 963.69 Euro (OPS 5 - 431.x and OPS 8 - 123.0) for the recommended two-step treatment. Conclusion: Fluoroscopic-guided primary single-step treatment with Freka {sup registered} Gastro Tube system is feasible and not associated with an increased complication rate when compared to published literature applying a two-step treatment approach. Material costs as well as human and time resources could be significantly reduced using the single-step treatment. (orig.)

  8. Control rod guide tube wear in operating reactors; operating experience report. Technical report December 1977-December 1979

    International Nuclear Information System (INIS)

    Riggs, R.

    1980-04-01

    Evidence of control rod guide tube wear has been observed in operating pressurized water reactors. The cause of this wear is identified as flow-induced vibration of the control rods. This report describes the measures being taken by both the industry and the NRC to deal with this matter. The staff also presents its technical positions and requirements to support continued operation of the plants as of December 1979 pending completion of this generic effort

  9. [Prehospital airway management of laryngeal tubes. Should the laryngeal tube S with gastric drain tube be preferred in emergency medicine?].

    Science.gov (United States)

    Dengler, V; Wilde, P; Byhahn, C; Mack, M G; Schalk, R

    2011-02-01

    Laryngeal tubes (LT) are increasingly being used for emergency airway management. This article reports on two patients in whom out-of-hospital intubation with a single-lumen LT was associated with massive pulmonary aspiration in one patient and gastric overinflation in the other. In both cases peak inspiratory pressures exceeded the LT leak pressure of approximately 35 mbar. This resulted in gastric inflation and decreased pulmonary compliance and increased inspiratory pressure further, thereby creating a vicious circle. It is therefore recommended that laryngeal tube suction (LTS) should be used in all cases of emergency airway management and a gastric drain tube be inserted through the dedicated second lumen. Apart from gastric overinflation, incorrect LT/LTS placement must be detected and immediately corrected, e.g. in cases of difficult or impossible gastric tube placement, permanent drainage of air from the gastric tube, decreasing minute ventilation or an ascending capnography curve.

  10. Boiling curve in high quality flow boiling

    International Nuclear Information System (INIS)

    Shiralkar, B.S.; Hein, R.A.; Yadigaroglu, G.

    1980-01-01

    The post dry-out heat transfer regime of the flow boiling curve was investigated experimentally for high pressure water at high qualities. The test section was a short round tube located downstream of a hot patch created by a temperature controlled segment of tubing. Results from the experiment showed that the distance from the dryout point has a significant effect on the downstream temperatures and there was no unique boiling curve. The heat transfer coefficients measured sufficiently downstream of the dryout point could be correlated using the Heineman correlation for superheated steam, indicating that the droplet deposition effects could be neglected in this region

  11. Design of a Kaplan turbine for a wide range of operating head -Curved draft tube design and model test verification-

    Science.gov (United States)

    KO, Pohan; MATSUMOTO, Kiyoshi; OHTAKE, Norio; DING, Hua

    2016-11-01

    As for turbomachine off-design performance improvement is challenging but critical for maximising the performing area. In this paper, a curved draft tube for a medium head Kaplan type hydro turbine is introduced and discussed for its significant effect on expanding operating head range. Without adding any extra structure and working fluid for swirl destruction and damping, a carefully designed outline shape of draft tube with the selected placement of center-piers successfully supresses the growth of turbulence eddy and the transport of the swirl to the outlet. Also, more kinetic energy is recovered and the head lost is improved. Finally, the model test results are also presented. The obvious performance improvement was found in the lower net head area, where the maximum efficiency improvement was measured up to 20% without compromising the best efficiency point. Additionally, this design results in a new draft tube more compact in size and so leads to better construction and manufacturing cost performance for prototype. The draft tube geometry parameter designing process was concerning the best efficiency point together with the off-design points covering various water net heads and discharges. The hydraulic performance and flow behavior was numerically previewed and visualized by solving Reynolds-Averaged Navier-Stokes equations with Shear Stress Transport turbulence model. The simulation was under the assumption of steady-state incompressible turbulence flow inside the flow passage, and the inlet boundary condition was the carefully simulated flow pattern from the runner outlet. For confirmation, the corresponding turbine efficiency performance of the entire operating area was verified by model test.

  12. Actions undertaken in order to solve the tube guide pins cracking

    International Nuclear Information System (INIS)

    Benhamou, C.; Briois, J.P.; Tuncer, T.; Drean, H.

    1985-01-01

    Short-term actions have been developed after the discovery of defects on the guide tube pins (upper internal rector components) of 21 units in France. The impact analysis of a pin failure on the safety by Framatome show that short-term consequences are not very important. Improvements in regard with the design and the stress corrosion resistance of the material, which can be applied to the pins, have been defined. Framatome and EDF developed tools and the mastery of replacement operations what led to limit considerably the unavailability of units; 17 units have been treated for two years and half; the four last ones will be treated in 1985. Parallel studies allow to estimate the available marge of in-service behavior of the replacement pins; this marge is increased in units which are built now by means of new developments concerning the design and the mounting conditions. A method and tools utilizing ultrasonic waves have been developed for on-site inspection of the pins [fr

  13. Verification of neutron pad and 17 x 7 guide tube designs by preoperational tests on the Trojan I power plant

    International Nuclear Information System (INIS)

    Bloyd, C.N.; Singleton, N.R.; Ciaramitaro, W.

    1976-05-01

    The internals vibration measurement program carried out on the Trojan-1 reactor during preoperational testing is described. The flow induced response of a 17 x 17 guide tube and the neutron pad core barrel were deduced from the plant test data and compared with the expected responses. The results showed good agreement with expected vibration levels

  14. Three dimensional numerical investigation of flow mixing in curved tubes and mass transfer in T-channel junction

    International Nuclear Information System (INIS)

    Pandey, Pradeep; Nayak, A.K.; Vijayan, P.K.

    2014-01-01

    Three dimensional flow patterns appearing in geometries such as curved pipes and T-channel junctions have important applications and are attractive for research. Unlike the flow in a straight tube, fluid motion in a curved tube is not parallel to the axis of bend, owing to the presence of centrifugal effects. It is characterized by a secondary flow in a cross-sectional plane normal to the main flow. Consequently, secondary flow separation near the inner wall is observed in the developing region. The strength of the secondary flow is greatly influenced by the curvature ratio and in turn, a non-dimensional parameter called the Dean Number. Secondary flow increases flow resistance, resulting in a larger pressure drop along the bend. The location of the maximum axial velocity gets shifted towards the outer wall. Flow in a T-channel junction is also a configuration of great significance. The simulations of the present work show that flow at low Reynolds numbers (Re ≤ 115) is steady and symmetric. For low Reynolds numbers, flow in the downstream channel remains highly segregated about the centerline. The appearance of vortices in the T-channel junction does little to redistribute concentration when flow remains symmetric. With increasing Reynolds number, transition takes place towards asymmetric flow. The incoming flow field gets redistributed at the center-plane and the dividing streamline becomes increasingly distorted. The flow field is characterized by thin elongated fluid interfaces across which momentum diffusion takes place. Flow at higher Reynolds numbers (Re ≥ 250) becomes unsteady in which unstable stagnation stream traces move periodically leftward and rightward at top and bottom walls. Trajectories of mass-less particles show greater dwelling in the junction as compared to those of finite mass particle. The numerical simulation is carried out in the present work using ANUPRAVAHA, a general purpose CFD solver developed at IIT Kanpur in collaboration with

  15. Apparatus for inspecting and repairing a pressurized-water reactor's steam generator heat exchanger tubes

    International Nuclear Information System (INIS)

    Mueller, O.; Roettger, H.; Kasti, H.; Hagen, H.G.

    1976-01-01

    Described is an apparatus provided for use with a pressurized-water reactor' steam generator having a manifold chamber enclosing the bottom side of a horizontal tube sheet having holes therethrough in which are mounted the tubes of a heat exchanger tube bundle. The manifold chamber has a manhole giving access to the tube's bottom side to permit internal inspection or repair of the tubes by registration of an end of a flexible guide conduit with the tube sheet holes and through which a flexible carrier can be guided for insertion via these holes in the tube sheet and through the tubes extending from the tube sheet's other side

  16. Fluoroscopically-guided transnasal insertion of ileus tube intestinal decompression in patients with inoperable malignant bowel obstruction

    International Nuclear Information System (INIS)

    Fang Shiming; Li Haili; Lin Qing; Mao Aiwu; Wu Shaoqiu; Jiang Haosheng; Cao Yan; Wang Zhenlei

    2011-01-01

    Objective: To assess the technical feasibility and effectiveness of fluoroscopically-guided transnasal insertion of ileus tube for intestinal decompression in the treatment of inoperable malignant bowel obstruction. Methods: A total of 211 patients with inoperable malignant bowel obstruction were enrolled in this study. The median KPS scale was 40 (ranged from 20 to 60). Under fluoroscopic guidance, transnasal insertion of ileus tube by using conventional technique or guidewire-catheter exchange technique was performed in all patients. The technical success rate, the clinical effective rate, the curative rate and adverse reactions as well as complications were documented. The correlation among the obstructive sites, obstruction causes and therapeutic effectiveness was analyzed. The ileus tube used in this study was a four-cavity and double-balloon catheter with a diameter of 16 F/18 f, which is produced by Cliny Company. Results: Transnasal drainage tube was successfully inserted into the proximal jejunum in all 211 patients with malignant bowel obstruction, and the total technical success rate was 100%. The initial technical success rate of the traditional technique and the catheter-guidewire exchange method was 85.5% (65/76) and 100% (135/135) respectively, the difference between the two was significant (P<0.05). After 24 hours, the clinical remission rate in the patients with high-level intestinal obstruction, lower-level intestinal obstruction and colorectal obstruction was 95.8% (46/48), 92.9% (117/126) and 83.8% (31/37), respectively. A follow-up of 4-245 days (mean 138 days) was conducted, and the total clinical cure rate was 27.5% (58/211). The clinical cure rate in small intestine obstruction and colorectal obstruction caused by primary tumor or recurrence was 12.7% (20/157) and 59.5% (22/37), respectively (P<0.05). The adverse reactions and complications included uncomfortable pharynx feeling or pain (99.1%, 199/221), the tube obstruction (23.2%, 49

  17. Corium Configuration and Penetration Tube Failure for Fukushima Daiichi Nuclear Power Plant

    International Nuclear Information System (INIS)

    An, Sang Mo; Lee, Jae Bong; Kim, Hwan Yeol; Song, Jin Ho

    2016-01-01

    For the LWRs (light water reactors), the penetration tubes at the reactor vessel lower head are regarded as the most vulnerable structures along with a global vessel failure during a severe accident because they can be seriously damaged by a corium melt or debris relocated into the lower plenum of the vessel. The research on the penetration tube failure is of higher importance in the BWRs, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. There are more than one hundred of penetration tubes in the Fukushima Daiichi NPPs (nuclear power plants), such as ICM-GTs (in-core monitoring guide tubes), CRGTs (control rod guide tubes) and drain tubes. The ICM-GTs include SRMs (source range monitors), IRMs (intermediate range monitors), LPRMs (local power range monitors) and TIPs (traversing in-core probes), which are much thinner than other tubes. The experimental researches to investigate the corium configuration and the penetration tube failure for the Fukushima Daiichi NPPs were introduced and some meaningful results were summarized. It was shown that the corium ingot was separated into two layers, of which the upper layer was metal-rich while the lower one was oxide-rich. It seemed that B 4 C would contribute to reducing the density of the metallic melt. The two-layered configuration will provide useful information to understand the core melt progression and post-recovery actions for the Fukushima Daiichi NPPs. In addition, we performed a large scale penetration tube failure experiment for the SRM/IRM guide tube, and showed high possibilities of large amount of corium discharge out of the reactor vessel lower head, which followed by the tube melting in a very short time. We are planning to perform the penetration tube failure experiments for another dry tube of ICM-GT (LPRM guide tube), and later for the wet tube (CRGT)

  18. Corium Configuration and Penetration Tube Failure for Fukushima Daiichi Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    An, Sang Mo; Lee, Jae Bong; Kim, Hwan Yeol; Song, Jin Ho [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    For the LWRs (light water reactors), the penetration tubes at the reactor vessel lower head are regarded as the most vulnerable structures along with a global vessel failure during a severe accident because they can be seriously damaged by a corium melt or debris relocated into the lower plenum of the vessel. The research on the penetration tube failure is of higher importance in the BWRs, as it could lead to melt discharge into the containment and subsequent release of radioactive materials to the environment due to the containment failure. There are more than one hundred of penetration tubes in the Fukushima Daiichi NPPs (nuclear power plants), such as ICM-GTs (in-core monitoring guide tubes), CRGTs (control rod guide tubes) and drain tubes. The ICM-GTs include SRMs (source range monitors), IRMs (intermediate range monitors), LPRMs (local power range monitors) and TIPs (traversing in-core probes), which are much thinner than other tubes. The experimental researches to investigate the corium configuration and the penetration tube failure for the Fukushima Daiichi NPPs were introduced and some meaningful results were summarized. It was shown that the corium ingot was separated into two layers, of which the upper layer was metal-rich while the lower one was oxide-rich. It seemed that B{sub 4}C would contribute to reducing the density of the metallic melt. The two-layered configuration will provide useful information to understand the core melt progression and post-recovery actions for the Fukushima Daiichi NPPs. In addition, we performed a large scale penetration tube failure experiment for the SRM/IRM guide tube, and showed high possibilities of large amount of corium discharge out of the reactor vessel lower head, which followed by the tube melting in a very short time. We are planning to perform the penetration tube failure experiments for another dry tube of ICM-GT (LPRM guide tube), and later for the wet tube (CRGT)

  19. Development of Evaluation Technology of the Integrity of HWR Pressure Tubes

    International Nuclear Information System (INIS)

    Kim, Y. S.; Jeong, Y. M.; Ahn, S. B.

    2005-03-01

    Major degradation of the feeder pipe is the thinning due to the flow accelerated corrosion and the cracking in the bent region due to the stress corrosion cracking. The feeder pipe in a PHWR is a pipe to supply the coolant to the pressure tube and the heated coolant to the steam generator for power generation. Approximately 380 pipes are installed on the inlet side and outlet side each with two bent regions in the 600 MW-class PHWR. After a leakage in the bent region of the feeder pipe, it is required to examine all the pipes in order to ensure the integrity of the pressure boundaries. It is not easy, however, to examine all the pipes with the conventional ultrasonic method, because of a high dose of radiation exposure and a limited accessibility to the pipe. In order to get rid of the limited accessibility, the ultrasonic guided wave method are developed for detection and evaluation of the cracks in the feeder pipe. The dispersion mode analysis was performed for the development of long-range guided wave inspection for the feeder pipe. An analytical approach for the straight pipe as well as numerical approach for the bent pipe with 2-D FFT were accomplished. A computer program for the calculation of the dispersion curves and wave structures was developed. Based on the dispersion curves and wave structure of the feeder pipe, candidates for the optimal parameters on the frequencies and vibration modes were selected. A time-frequency analysis methodology was developed for the mode identification of received ultrasonic signal. A high power tone-burst ultrasonic system has been setup for the generation of guided waves. Various artificial notches were fabricated on the bent feeder pipes for the experiment on the flaw detection. Considering the results of dispersion analysis and field condition, the torsional vibration mode, T(0,1) is selected for the first choice. An array of electromagnetic acoustic transducers (EMAT) was designed and fabricated for the generation of T

  20. Development of Evaluation Technology of the Integrity of HWR Pressure Tubes

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Y S; Jeong, Y M; Ahn, S B [and others

    2005-03-15

    Major degradation of the feeder pipe is the thinning due to the flow accelerated corrosion and the cracking in the bent region due to the stress corrosion cracking. The feeder pipe in a PHWR is a pipe to supply the coolant to the pressure tube and the heated coolant to the steam generator for power generation. Approximately 380 pipes are installed on the inlet side and outlet side each with two bent regions in the 600 MW-class PHWR. After a leakage in the bent region of the feeder pipe, it is required to examine all the pipes in order to ensure the integrity of the pressure boundaries. It is not easy, however, to examine all the pipes with the conventional ultrasonic method, because of a high dose of radiation exposure and a limited accessibility to the pipe. In order to get rid of the limited accessibility, the ultrasonic guided wave method are developed for detection and evaluation of the cracks in the feeder pipe. The dispersion mode analysis was performed for the development of long-range guided wave inspection for the feeder pipe. An analytical approach for the straight pipe as well as numerical approach for the bent pipe with 2-D FFT were accomplished. A computer program for the calculation of the dispersion curves and wave structures was developed. Based on the dispersion curves and wave structure of the feeder pipe, candidates for the optimal parameters on the frequencies and vibration modes were selected. A time-frequency analysis methodology was developed for the mode identification of received ultrasonic signal. A high power tone-burst ultrasonic system has been setup for the generation of guided waves. Various artificial notches were fabricated on the bent feeder pipes for the experiment on the flaw detection. Considering the results of dispersion analysis and field condition, the torsional vibration mode, T(0,1) is selected for the first choice. An array of electromagnetic acoustic transducers (EMAT) was designed and fabricated for the generation of T

  1. Tube to limit a bundle of penetrating rays

    International Nuclear Information System (INIS)

    Arauner, A.

    1980-01-01

    The tube of the X-ray therapy equipment, which is adjustable in width, guarantees the same dose rate in the edge zone for all tube widths which can be set. The tube for this purpose consists of wall segments, which can be individually moved via shafts at right angles to their own axis and the axis of symmetry of the tube. The inclination of the wall elements to the axis of symmetry is adjustable by levers running in a curve. (RW) [de

  2. Construction of calibration curve for accountancy tank

    International Nuclear Information System (INIS)

    Kato, Takayuki; Goto, Yoshiki; Nidaira, Kazuo

    2009-01-01

    Tanks are equipped in a reprocessing plant for accounting solution of nuclear material. The careful measurement of volume in tanks is very important to implement rigorous accounting of nuclear material. The calibration curve relating the volume and level of solution needs to be constructed, where the level is determined by differential pressure of dip tubes. Several calibration curves are usually employed, but it's not explicitly decided how many segment are used, where to select segment, or what should be the degree of polynomial curve. These parameters, i.e., segment and degree of polynomial curve are mutually interrelated to give the better performance of calibration curve. Here we present the construction technique of giving optimum calibration curves and their characteristics. (author)

  3. Validating eddy current array probes for inspecting steam generator tubes

    International Nuclear Information System (INIS)

    Sullivan, S.P.; Cecco, V.S.; Obrutsky, L.S.

    1997-01-01

    A CANDU nuclear reactor was shut down for over one year because steam generator (SG) tubes had failed with outer diameter stress-corrosion cracking (ODSCC) in the U-bend section. Novel, single-pass eddy current transmit-receive probes, denoted as C3, were successful in detecting all significant cracks so that the cracked tubes could be plugged and the unit restarted. Significant numbers of tubes with SCC were removed from a SG in order to validate the results of the new probe. Results from metallurgical examinations were used to obtain probability-of-detection (POD) and sizing accuracy plots to quantify the performance of this new inspection technique. Though effective, the above approach of relying on tubes removed from a reactor is expensive, in terms of both economic and radiation-exposure costs. This led to a search for more affordable methods to validate inspection techniques and procedures. Methods are presented for calculating POD curves based on signal-to-noise studies using field data. Results of eddy current scans of tubes with laboratory-induced ODSCC are presented with associated POD curves. These studies appear promising in predicting realistic POD curves for new inspection technologies. They are being used to qualify an improved eddy current array probe in preparation for field use. (author)

  4. Thermal isocreep curves obtained during multi-axial creep tests on recrystallized Zircaloy-4 and M5™ alloy

    International Nuclear Information System (INIS)

    Rautenberg, M.; Poquillon, D.; Pilvin, P.; Grosjean, C.; Cloué, J.M.; Feaugas, X.

    2014-01-01

    Zirconium alloys are widely used in the nuclear industry. Several components, such as cladding or guide tubes, undergo strong mechanical loading during and after their use inside the pressurized water reactors. The current requirements on higher fuel performances lead to the developing on new Zr based alloys exhibiting better mechanical properties. In this framework, creep behaviors of recrystallized Zircaloy-4 and M5™, have been investigated and then compared. In order to give a better understanding of the thermal creep anisotropy of Zr-based alloys, multi-axial creep tests have been carried out at 673 K. Using a specific device, creep conditions have been set using different values of β = σ zz /σ θθ , σ zz and σ θθ being respectively the axial and hoop creep stresses. Both axial and hoop strains are measured during each test which is carried out until stationary creep is stabilized. The steady-state strain rates are then used to build isocreep curves. Considering the isocreep curves, the M5™ alloy shows a largely improved creep resistance compared to the recrystallized Zircaloy-4, especially for tubes under high hoop loadings (0 < β < 1). The isocreep curves are then compared with simulations performed using two different mechanical models. Model 1 uses a von Mises yield criterion, the model 2 is based on a Hill yield criterion. For both models, a coefficient derived from Norton law is used to assess the stress dependence

  5. YouTube An Insider's Guide to Climbing the Charts

    CERN Document Server

    Lastufka, Alan

    2008-01-01

    If you want to make a splash on YouTube with your videos, this book shows you what it takes. It's written by two YouTube veterans who know how to make quality video art, and have the subscribers and millions of views to prove it. They'll take you through the basics, and will teach you how to write, shoot, edit, optimize, upload, and promote your work.

  6. A fast position estimation method for a control rod guide tube inspection robot with a single camera

    International Nuclear Information System (INIS)

    Lee, Jae C.; Seop, Jun H.; Choi, Yu R.; Kim, Jae H.

    2004-01-01

    One of the problems in the inspection of control rod guide tubes using a mobile robot is accurate estimation of the robot's position. The problem is usually explained by the question 'Where am I?'. We can solve this question by a method called dead reckoning using odometers. But it has some inherent drawbacks such that the position error grows without bound unless an independent reference is used periodically to reduce the errors. In this paper, we presented one method to overcome this drawback by using a vision sensor. Our method is based on the classical Lucas Kanade algorithm for on image tracking. In this algorithm, an optical flow must be calculated at every image frame, thus it has intensive computing load. In order to handle large motions, it is preferable to use a large integration window. But a small integration window is more preferable to keep the details contained in the images. We used the robot's movement information obtained from the dead reckoning as an input parameter for the feature tracking algorithm in order to restrict the position of an integration window. By means of this method, we could reduce the size of an integration window without any loss of its ability to handle large motions and could avoid the trade off in the accuracy. And we could estimate the position of our robot relatively fast without on intensive computing time and the inherent drawbacks mentioned above. We studied this algorithm for applying it to the control rod guide tubes inspection robot and tried an inspection without on operator's intervention

  7. Protective guide structure for reactor control rod

    International Nuclear Information System (INIS)

    Ban, Minoru; Umeda, Kenji; Kubo, Noboru; Ito, Tomohiro.

    1996-01-01

    The present invention provides an improved protective guide structure for control rods, which does not cause swirling of coolants and resonance even though a slit is formed on a protective tube which surrounds a control rod element in a PWR type reactor. Namely, a reactor control rod is constituted with elongated control elements collectively bundled in the form of a cluster. The protective guide structure protectively guides the collected constituent at the upper portion of a reactor container. The protective structure comprises a plurality of protective tubes each having a C-shaped cross section disposed in parallel for receiving control rod elements individually in which the corners of the opening of the cross section of the protective tube are chamfered to an appropriate configuration. With such a constitution, even if coolant flows in a circumferential direction along the protective tubes surrounding the control rod elements, no shearing stream is caused to the coolants flow since the corners of the cross sectional opening (slit) of the tube are chamfered. Accordingly, occurrence of swirlings can be suppressed. (I.S.)

  8. Experimental study of flow friction characteristics of integral pin-fin tubes

    International Nuclear Information System (INIS)

    Ding Ming; Yan Changqi; Sun Licheng

    2007-01-01

    Friction characteristics of integral pin-fin tubes, through which lubricating-oil flowed vertically, were studied experimentally. Effects of the pitch, the height of fins and the machining direction on friction coefficient were analyzed. The experimental results showed that the friction coefficient of the integral pin-fro tube was obviously lager than that of smooth tube. Compared with other influential factors, the effect of the height of fins was dominant. Because the three-dimensional pin fin could disturb and destroy the boundary layer, when the Reynolds Number reached 200-300, the friction coefficient curve began to bend, that was, a turning point was appeared in the friction coefficient curve. (authors)

  9. PEG tubes: dealing with complications.

    Science.gov (United States)

    Malhi, Hardip; Thompson, Rosie

    A percutaneous endoscopic gastronomy tube can be used to deliver nutrition, hydration and medicines directly into the patient's stomach. Patients will require a tube if they are unable to swallow safely, putting them at risk of aspiration of food, drink and medicines into their lungs. It is vital that nurses are aware of the complications that may arise when caring for a patient with a PEG tube. It is equally important that nurses know how to deal with these complications or from where tc seek advice. This article provides a quick troubleshooting guide to help nurses deal with complications that can arise with PEG feeding.

  10. Dashport construction for a nuclear reactor rod guide thimble

    International Nuclear Information System (INIS)

    John, C.D. Jr.; Sparrow, J.A.

    1991-01-01

    This patent describes a control rod guide thimble having a main hollow tube defining a substantial portion of the length of the guide thimble. It comprises: a lower tubular portion of the man hollow tube; and an auxiliary hollow tube having concentric exterior and interior surfaces, the auxiliary tube being inserted in the lower portion of the main hollow tube and having an outside diameter slightly less than an inside diameter of the main tube to permit a close fitting relationship between the exterior surface and the auxiliary tube and an interior surface of the main tube lower portion, the auxiliary tube having an upper end portion with an inside surface portion in axial cross-section flaring in inclined relation upwardly and outwardly to provide a tapered transition extending between and connecting the interior surface of the auxiliary tube with the exterior surface thereof; and an end plug attached to a lower end of the auxiliary tube

  11. Microvascular Anastomosis: Proposition of a Learning Curve.

    Science.gov (United States)

    Mokhtari, Pooneh; Tayebi Meybodi, Ali; Benet, Arnau; Lawton, Michael T

    2018-04-14

    Learning to perform a microvascular anastomosis is one of the most difficult tasks in cerebrovascular surgery. Previous studies offer little regarding the optimal protocols to maximize learning efficiency. This failure stems mainly from lack of knowledge about the learning curve of this task. To delineate this learning curve and provide information about its various features including acquisition, improvement, consistency, stability, and recall. Five neurosurgeons with an average surgical experience history of 5 yr and without any experience in bypass surgery performed microscopic anastomosis on progressively smaller-caliber silastic tubes (Biomet, Palm Beach Gardens, Florida) during 24 consecutive sessions. After a 1-, 2-, and 8-wk retention interval, they performed recall test on 0.7-mm silastic tubes. The anastomoses were rated based on anastomosis patency and presence of any leaks. Improvement rate was faster during initial sessions compared to the final practice sessions. Performance decline was observed in the first session of working on a smaller-caliber tube. However, this rapidly improved during the following sessions of practice. Temporary plateaus were seen in certain segments of the curve. The retention interval between the acquisition and recall phase did not cause a regression to the prepractice performance level. Learning the fine motor task of microvascular anastomosis adapts to the basic rules of learning such as the "power law of practice." Our results also support the improvement of performance during consecutive sessions of practice. The objective evidence provided may help in developing optimized learning protocols for microvascular anastomosis.

  12. Collapse of thin wall tubes small initial ovality

    International Nuclear Information System (INIS)

    Moreno, A.

    1977-01-01

    In this work a simple model of creep collapse of tubes based on the bending theory of curved beams, is developed. The model is compared with more complex models. The main result of this work is the definition of a new model of creep collapse of tubes with a minimum of limitative hypothesis. (Author) 6 refs

  13. Flexural Behavior of GFRP Tubes Filled with Magnetically Driven Concrete.

    Science.gov (United States)

    Xie, Fang; Chen, Ju; Dong, Xinlong; Feng, Bing

    2018-01-08

    Experimental investigation of GFRP (glass fiber reinforced polymer) tubes that were filled with magnetically driven concrete was carried out to study the flexural behavior of specimens under bending. Specimens having different cross section and lengths were tested. The test specimens were fabricated by filling magnetically driven concrete into the GFRP tubes and the concrete was vibrated using magnetic force. Specimens vibrated using vibrating tube were also tested for comparison. In addition, specimens having steel reinforcing bars and GFRP bars were both tested to study the effect of reinforcing bars on the magnetically driven concrete. The load-displacement curves, load-strain curves, failure mode, and ultimate strengths of test specimens were obtained. Design methods for the flexural stiffness of test specimens were also discussed in this study.

  14. Modern cryptography and elliptic curves a beginner's guide

    CERN Document Server

    Shemanske, Thomas R

    2017-01-01

    This book offers the beginning undergraduate student some of the vista of modern mathematics by developing and presenting the tools needed to gain an understanding of the arithmetic of elliptic curves over finite fields and their applications to modern cryptography. This gradual introduction also makes a significant effort to teach students how to produce or discover a proof by presenting mathematics as an exploration, and at the same time, it provides the necessary mathematical underpinnings to investigate the practical and implementation side of elliptic curve cryptography (ECC). Elements of abstract algebra, number theory, and affine and projective geometry are introduced and developed, and their interplay is exploited. Algebra and geometry combine to characterize congruent numbers via rational points on the unit circle, and group law for the set of points on an elliptic curve arises from geometric intuition provided by Bézout's theorem as well as the construction of projective space. The structure of the...

  15. Graphics and control of the guide tube assembly reinforcement manipulators at Sizewell 'A'

    International Nuclear Information System (INIS)

    Burden, C.

    1996-01-01

    A method was devised to reinforce the lower lug welds of the Guide Tube Assemblies (GTA's) at Sizewell 'A'. A six degree of freedom manipulator was designed to place a clamp around the lugs and tighten it. The manipulator was fitted with the three fixed cameras but required another surveillance manipulator positioned in an adjacent standpipe to provide additional views. The need to prepare two standpipes limited the rate at which reinforcements could be made. Therefore an articulated two arm camera manipulator, which could be used on the existing manipulator mast was designed and built. The two manipulators were driven from separate desks and were controlled by the same supervisory computer linked to online graphics. The camera arm joints were driven on preplanned routes using a single joystick because of the complex moves and tight spaces involved. A large number of GTA sites have now been reinforced including a dropped GTA which had to be raised to carry out clamping. (Author)

  16. Externally guided target for inertial fusion

    International Nuclear Information System (INIS)

    Martinez-Val, J.M.; Piera, M.

    1996-01-01

    A totally new concept is proposed to reach fusion conditions by externally guided inertial confinement. The acceleration and compression of the fuel is guided by a cannon-like external duct with a conical section ending in a small-size cavity around the central point of the tube. The fuel pellets coming from each cannon mouth collide in the central cavity where the implosion and final compression of the fuel take place. Both the tube material density and its areal density must be much higher than the initial density and areal density of the fuel. The external tube will explode into pieces as a consequence of the inner pressures achieved after the fuel central collision. If the collision is suitably driven, a fusion burst can take place before the tube disassembly. because of the features of the central collision needed to trigger ignition, this concept could be considered as tamped impact fusion. Both the fusion products and the debris from the guide tube are caught by a liquid-lithium curtain surrounding the target. Only two driving beams are necessary. The system can be applied to any type of driver and could use a solid pellet at room temperature as the initial target. 54 refs., 24 figs., 1 tab

  17. Collapse of thin wall tubes with small initial ovality

    International Nuclear Information System (INIS)

    Moreno, A.

    1977-01-01

    A simple model of creep collapse of tubes based on the bending theory of curved beams is developed. The model is compared with more complex models. The main result of this study is the definition of a new model of creep collapse of tubes with a minimum of limited hypothesis. (author) [es

  18. Crack resistance curve determination of zircaloy-4 cladding

    International Nuclear Information System (INIS)

    Bertsch, J.; Alam, A.; Zubler, R.

    2009-03-01

    Fracture mechanics properties of fuel claddings are of relevance with respect to fuel rod integrity. The integrity of a fuel rod, in turn, is important for the fuel performance, for the safe handling of fuel rods, for the prevention of leakages and subsequent dissemination of fuel, for the avoidance of unnecessary dose rates, and for safe operation. Different factors can strongly deteriorate the mechanical fuel rod properties: irradiation damage, thermo-mechanical impact, corrosion or hydrogen uptake. To investigate the mechanical properties of fuel rod claddings which are used in Swiss nuclear power plants, PSI has initiated a program for mechanical testing. A major issue was the interaction between specific loading devices and the tested cladding tube, e.g. in the form of bending or friction. Particular for Zircaloy is the hexagonal closed packed structure of the zirconium crystallographic lattice. This structure implies plastic deformation mechanisms with specific, preferred orientations. Further, the manufacturing procedure of Zircaloy claddings induces a specific texture which plays a salient role with respect to the embrittlement by irradiation or integration of hydrogen in the form of hydrides. Both, the induced microstructure as well as the plastic deformation behaviour play a role for the mechanical properties. At PSI, in a first step inactive thin walled Zircaloy tubes and, for comparison reasons, plates were tested. The validity of the mechanical testing of the non standard tube and plate geometries had to be verified. The used Zircaloy-4 cladding tube sections and small plates of the same wall thickness have been notched, fatigue pre-cracked and tensile tested to evaluate the fracture toughness properties at room temperature, 300 o C and 350 o C. The crack propagation has been determined optically. The test results of the plates have been further used to validate FEM calculations. For each sample a complete crack resistance (J-R) curve could be

  19. Crack resistance curve determination of zircaloy-4 cladding

    Energy Technology Data Exchange (ETDEWEB)

    Bertsch, J.; Alam, A.; Zubler, R

    2009-03-15

    Fracture mechanics properties of fuel claddings are of relevance with respect to fuel rod integrity. The integrity of a fuel rod, in turn, is important for the fuel performance, for the safe handling of fuel rods, for the prevention of leakages and subsequent dissemination of fuel, for the avoidance of unnecessary dose rates, and for safe operation. Different factors can strongly deteriorate the mechanical fuel rod properties: irradiation damage, thermo-mechanical impact, corrosion or hydrogen uptake. To investigate the mechanical properties of fuel rod claddings which are used in Swiss nuclear power plants, PSI has initiated a program for mechanical testing. A major issue was the interaction between specific loading devices and the tested cladding tube, e.g. in the form of bending or friction. Particular for Zircaloy is the hexagonal closed packed structure of the zirconium crystallographic lattice. This structure implies plastic deformation mechanisms with specific, preferred orientations. Further, the manufacturing procedure of Zircaloy claddings induces a specific texture which plays a salient role with respect to the embrittlement by irradiation or integration of hydrogen in the form of hydrides. Both, the induced microstructure as well as the plastic deformation behaviour play a role for the mechanical properties. At PSI, in a first step inactive thin walled Zircaloy tubes and, for comparison reasons, plates were tested. The validity of the mechanical testing of the non standard tube and plate geometries had to be verified. The used Zircaloy-4 cladding tube sections and small plates of the same wall thickness have been notched, fatigue pre-cracked and tensile tested to evaluate the fracture toughness properties at room temperature, 300 {sup o}C and 350 {sup o}C. The crack propagation has been determined optically. The test results of the plates have been further used to validate FEM calculations. For each sample a complete crack resistance (J-R) curve could

  20. Tube structural integrity evaluation of Palo Verde Unit 1 steam generators for axial upper-bundle cracking

    International Nuclear Information System (INIS)

    Woodman, B.W.; Begley, J.A.; Brown, S.D.; Sweeney, K.; Radspinner, M.; Melton, M.

    1995-01-01

    The analysis of the issue of upper bundle axial ODSCC as it apples to steam generator tube structural integrity in Unit 1 at the Palo Verde Nuclear generating Station is presented in this study. Based on past inspection results for Units 2 and 3 at Palo Verde, the detection of secondary side stress corrosion cracks in the upper bundle region of Unit 1 may occur at some future date. The following discussion provides a description and analysis of the probability of axial ODSCC in Unit 1 leading to the exceedance of Regulatory Guide 1.121 structural limits. The probabilities of structural limit exceedance are estimated as function of run time using a conservative approach. The chosen approach models the historical development of cracks, crack growth, detection of cracks and subsequent removal from service and the initiation and growth of new cracks during a given cycle of operation. Past performance of all Palo Verde Units as well as the historical performance of other steam generators was considered in the development of cracking statistics for application to Unit 1. Data in the literature and Unit 2 pulled tube examination results were used to construct probability of detection curves for the detection of axial IGSCC/IGA using an MRPC (multi-frequency rotating panake coil) eddy current probe. Crack growth rates were estimated from Unit 2 eddy current inspection data combined with pulled tube examination results and data in the literature. A Monte-Carlo probabilistic model is developed to provide an overall assessment of the risk of Regulatory Guide exceedance during plant operation

  1. The curve shortening problem

    CERN Document Server

    Chou, Kai-Seng

    2001-01-01

    Although research in curve shortening flow has been very active for nearly 20 years, the results of those efforts have remained scattered throughout the literature. For the first time, The Curve Shortening Problem collects and illuminates those results in a comprehensive, rigorous, and self-contained account of the fundamental results.The authors present a complete treatment of the Gage-Hamilton theorem, a clear, detailed exposition of Grayson''s convexity theorem, a systematic discussion of invariant solutions, applications to the existence of simple closed geodesics on a surface, and a new, almost convexity theorem for the generalized curve shortening problem.Many questions regarding curve shortening remain outstanding. With its careful exposition and complete guide to the literature, The Curve Shortening Problem provides not only an outstanding starting point for graduate students and new investigations, but a superb reference that presents intriguing new results for those already active in the field.

  2. Curves and surfaces for CAGD a practical guide

    CERN Document Server

    Farin, Gerald

    2002-01-01

    This fifth edition has been fully updated to cover the many advances made in CAGD and curve and surface theory since 1997, when the fourth edition appeared. Material has been restructured into theory and applications chapters. The theory material has been streamlined using the blossoming approach; the applications material includes least squares techniques in addition to the traditional interpolation methods. In all other respects, it is, thankfully, the same. This means you get the informal, friendly style and unique approach that has made Curves and Surfaces for CAGD: A Practical Gui

  3. Fracture toughness determination in steam generator tubes

    International Nuclear Information System (INIS)

    Bergant M; Yawny, A; Perez Ipina, J

    2012-01-01

    The assessment of the structural integrity of steam generator tubes in nuclear power plants deserved increasing attention in the last years due to the negative impact related to their failures. In this context, elastic plastic fracture mechanics (EPFM) methodology appears as a potential tool for the analysis. The application of EPFM requires, necessarily, knowledge of two aspects, i.e., the driving force estimation in terms of an elastic plastic toughness parameter (e.g., J) and the experimental measurement of the fracture toughness of the material (e.g., the material J-resistance curve). The present work describes the development of a non standardized experimental technique aimed to determine J-resistance curves for steam generator tubes with circumferential through wall cracks. The tubes were made of Incoloy 800 (Ni: 30.0-35.0; Cr: 19.0-23.0; Fe: 35.5 min, % in weight). Due to its austenitic microstructure, this alloy shows very high toughness and is widely used in applications where a good corrosion resistance in aqueous environment or an excellent oxidation resistance in high temperature environment is required. Finally, a procedure for the structural integrity analysis of steam generator tubes with crack-like defects, based on a FAD diagram (Failure Assessment Diagram), is briefly described (author)

  4. Modeling of second-harmonic generation of circumferential guided wave propagation in a composite circular tube

    Science.gov (United States)

    Li, Mingliang; Deng, Mingxi; Gao, Guangjian; Xiang, Yanxun

    2018-05-01

    This paper investigated modeling of second-harmonic generation (SHG) of circumferential guided wave (CGW) propagation in a composite circular tube, and then analyzed the influences of interfacial properties on the SHG effect of primary CGW. Here the effect of SHG of primary CGW propagation is treated as a second-order perturbation to its linear wave response. Due to the convective nonlinearity and the inherent elastic nonlinearity of material, there are second-order bulk driving forces and surface/interface driving stresses in the interior and at the surface/interface of a composite circular tube, when a primary CGW mode propagates along its circumference. Based on the approach of modal expansion analysis for waveguide excitation, the said second-order driving forces/stresses are regarded as the excitation sources to generate a series of double-frequency CGW modes that constitute the second-harmonic field of the primary CGW propagation. It is found that the modal expansion coefficient of each double-frequency CGW mode is closely related to the interfacial stiffness constants that are used to describe the interfacial properties between the inner and outer circular parts of the composite tube. Furthermore, changes in the interfacial stiffness constants essentially influence the dispersion relation of CGW propagation. This will remarkably affect the efficiency of cumulative SHG of primary CGW propagation. Some finite element simulations have been implemented of response characteristics of cumulative SHG to the interfacial properties. Both the theoretical analyses and numerical simulations indicate that the effect of cumulative SHG is found to be much more sensitive to changes in the interfacial properties than primary CGW propagation. The potential of using the effect of cumulative SHG by primary CGW propagation to characterize a minor change in the interfacial properties is considered.

  5. Ultrasonic measurement of gap between calandria tube and liquid injection shutdown system tube in PHWR

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Sohn, Seok Man; Lee, Jun Shin; Lee, Sun Ki; Lee, Jong Po

    2001-01-01

    Sag of CT or liquid injection shutdown system tubes in pressurized heavy water reactor is known to occur due to irradiation creep and growth during plant operation. When the sag of CT is big enough, the CT tube possibly comes in contact with liquid injection shutdown system tube (LIN) crossing beneath the CT, which subsequently may prevent the safe operation. It is therefore necessary to check the gap between the two tubes in order to confirm no contacts when using a proper measure periodically during the plant life. An ultrasonic gap measuring probe assembly which can be fed through viewing port installed on the calandria was developed and utilized to measure the sags of both tubes in a pressurized heavy water reactor in Korea. It was found that the centerlines of CT and LIN can be precisely detected by ultrasonic wave. The gaps between two tubes were easily obtained from the relative distance of the measured centerline elevations of the tubes. But the measured gap data observed at the viewing port were actually not the data at the crossing point of CT and LIN. To get the actual gap between two tubes, mathematical modeling for the deflection curves of two tubes was used. The sags of CT and LIN tubes were also obtained by comparison of the present centerlines with the initial elevations at the beginning of plant operation. The gaps between two tubes in the unmeasurable regions were calculated based on the measurement data and the channel power distribution

  6. Phased laser diode array permits selective excitation of ultrasonic guided waves in coated bone-mimicking tubes

    Science.gov (United States)

    Moilanen, Petro; Salmi, Ari; Kilappa, Vantte; Zhao, Zuomin; Timonen, Jussi; Hæggström, Edward

    2017-10-01

    This paper validates simulation predictions, which state that specific modes could be enhanced in quantitative ultrasonic bone testing. Tunable selection of ultrasonic guided wave excitation is useful in non-destructive testing since it permits the mediation of energy into diagnostically useful modes while reducing the energy mediated into disturbing contributions. For instance, it is often challenging to distinguish and extract the useful modes from ultrasound signals measured in bone covered by a soft tissue. We show that a laser diode array can selectively excite ultrasound in bone mimicking phantoms. A fiber-coupled diode array (4 elements) illuminated two solid tubes (2-3 mm wall thickness) embraced by an opaque soft-tissue mimicking elastomer coating (5 mm thick). A predetermined time delay matching the selected mode and frequency was employed between the outputs of the elements. The generated ultrasound was detected by a 215 kHz piezo receiver. Our results suggest that this array reduces the disturbances caused by the elastomer cover and so pave way to permit non-contacting in vivo guided wave ultrasound assessment of human bones. The implementation is small, inexpensive, and robust in comparison with the conventional pulsed lasers.

  7. Tubing misconnections: normalization of deviance.

    Science.gov (United States)

    Simmons, Debora; Symes, Lene; Guenter, Peggi; Graves, Krisanne

    2011-06-01

    Accidental connection of an enteral system to an intravenous (IV) system frequently results in the death of the patient. Misconnections are commonly attributed to the presence of universal connectors found in the majority of patient care tubing systems. Universal connectors allow for tubing misconnections between physiologically incompatible systems. The purpose of this review of case studies of tubing misconnections and of current expert recommendations for safe tubing connections was to answer the following questions: In tubing connections that have the potential for misconnections between enteral and IV tubing, what are the threats to safety? What are patient outcomes following misconnections between enteral and IV tubing? What are the current recommendations for preventing misconnections between enteral and IV tubing? Following an extensive literature search and guided by 2 models of threats and errors, the authors analyzed case studies and expert opinions to identify technical, organizational, and human errors; patient-related threats; patient outcomes; and recommendations. A total of 116 case studies were found in 34 publications. Each involved misconnections of tubes carrying feedings, intended for enteral routes, to IV lines. Overwhelmingly, the recommendations were for redesign to eliminate universal connectors and prevent misconnections. Other recommendations were made, but the analysis indicates they would not prevent all misconnections. This review of the published case studies and current expert recommendations supports a redesign of connectors to ensure incompatibility between enteral and IV systems. Despite the cumulative evidence, little progress has been made to safeguard patients from tubing misconnections.

  8. Fluoroscopy-Guided Removal of Pull-Type Gastrostomy Tubes

    International Nuclear Information System (INIS)

    Ahlers, Christopher M.; Schneider, Jens; Lachmann, Ricarda; Herber, Sascha; Dueber, Christoph; Pitton, Michael B.

    2008-01-01

    These case reports demonstrate a radiologic interventional technique for removal of pull-type gastrostomy tubes. This approach proved to be a safe and efficient procedure in two patients. The procedure may be applicable in situations where endoscopic attempts fail.

  9. Fabrication of seamless calandria tubes

    International Nuclear Information System (INIS)

    Saibaba, N.; Phanibabu, C.; Bhaskara Rao, C.V.; Kalidas, R.; Ganguly, C.

    2002-01-01

    Full text: Calandria tube is a large diameter, thin walled zircaloy-4 tube and is an important structural component of PHWR type of reactors. These tubes are lifetime components and remain during the full life of the reactor. Calandria tubes are classified as extremely thin walled tubes with a diameter to wall thickness ratio of around 96. Such thin walled tubes are conventionally produced by seam welded route comprising of extrusion of slabs followed by a series of hot and rolling passes, shaping into O-shape and eventual welding. An alternative and superior method of fabricating the calandria tubes, the seamless route, has been developed, which involves hot extrusion of mother blanks followed by three successive cold pilger reductions. Eccentricity correction of the extruded blanks is carried out on a special purpose grinding equipment to bring the wall thickness variation within permissible limits. Predominant wall thickness reductions are given during cold pilgering to ensure high Q-factor values. The texture in the finished tubes could be closely, controlled with an average f r value of 0.65. Pilgering parameters and tube guiding system have been specially designed to facilities rolling of thin walled tubes. Seamless calandria tubes have distinct advantages over welded tubes. In addition to the absence of weld, they are dimensionally more stable, lighter in weight and possess uniform grains with superior grain size. The cycle time from billet to finished product is substantially reduced and the product is amenable to high level of quality assurance. The most significant feature of the seamless route is its material recovery over welded route. Residual stresses measured in the tubes indicate that these are negligible and uniform along the length of the tube. In view of their superior quality, the first charge of seamless calandria tubes will be rolled into the first 500 MWe Pressurised Heavy Water Reactor at Tarapur

  10. Characterization of Friction Stir Welded Tubes by Means of Tube Bulge Test

    International Nuclear Information System (INIS)

    D'Urso, G.; Longo, M.; Giardini, C.

    2011-01-01

    Mechanical properties of friction stir welded joints are generally evaluated by means of conventional tensile test. This testing method might provide insufficient information because maximum strain obtained in tensile test before necking is small; moreover, the application of tensile test is limited when the joint path is not linear or even when the welds are executed on curved surfaces. Therefore, in some cases, it would be preferable to obtain the joints properties from other testing methods. Tube bulge test can be a valid solution for testing circumferential or longitudinal welds executed on tubular workpieces. The present work investigates the mechanical properties and the formability of friction stir welded tubes by means of tube bulge tests. The experimental campaign was performed on tubular specimens having a thickness of 3 mm and an external diameter of 40 mm, obtained starting from two semi-tubes longitudinally friction stir welded. The first step, regarding the fabrication of tubes, was performed combining a conventional forming process and friction stir welding. Sheets in Al-Mg-Si-Cu alloy AA6060 T6 were adopted for this purpose. Plates having a dimension of 225x60 mm were bent (with a bending axis parallel to the main dimension) in order to obtain semi-tubes. A particular care was devoted to the fabrication of forming devices (punch and die) in order to minimize the springback effects. Semi-tubes were then friction stir welded by means of a CNC machine tool. Some preliminary tests were carried out by varying the welding parameters, namely feed rate and rotational speed. A very simple tool having flat shoulder and cylindrical pin was used. The second step of the research was based on testing the welded tubes by means of tube bulge test. A specific equipment having axial actuators with a conical shape was adopted for this study. Some analyses were carried out on the tubes bulged up to a certain pressure level. In particular, the burst pressure and the

  11. Alternative method for predicting optimal insertion depth of the laryngeal tube in children.

    Science.gov (United States)

    Kim, J T; Jeon, S Y; Kim, C S; Kim, S D; Kim, H S

    2007-11-01

    Little information is available about the accuracy of the teeth mark on the laryngeal tube (LT) as a guide to correct placement in children. The aim of this crossover study was to evaluate three methods for optimal insertion depth of the size (#) 2 tube in children weighing 12-25 kg. In 24 children, the LT #2 was consecutively inserted by three different methods: (A) until the thick teeth mark on the tube was aligned with the upper incisors, (B) until resistance was felt, and (C) by inserting to a depth, previously measured, of the curved distance between the cricoid cartilage and the upper incisor. In each case, the depth of insertion, the degree of effective ventilation, the presence of leakage, and the fibreoptic view were assessed. Insertion based on the teeth mark led to a shorter insertion depth and a greater incidence of inadequate ventilation compared with the other two methods. There was no difference in the adequacy of ventilation between methods B and C. The vocal cords were more easily identified with methods B (62.5%) and C (75%) than with method A (12.5%). Insertion of the LT #2 aligned with the teeth mark can result in a shallow insertion depth and inadequate ventilation. The measured distance from the cricoid cartilage to the upper incisor offers alternative guidance for correct LT insertion.

  12. The learning curve for access creation in solo ultrasonography-guided percutaneous nephrolithotomy and the associated skills.

    Science.gov (United States)

    Yu, Weimin; Rao, Ting; Li, Xing; Ruan, Yuan; Yuan, Run; Li, Chenglong; Li, Haoyong; Cheng, Fan

    2017-03-01

    The aim of the current trial was to evaluate the learning curve of access creation through solo ultrasonography (US)-guided percutaneous nephrolithotomy (PCNL), and clarify the technical details of the procedure. We evaluated the first 240 solo US-guided PCNLs performed by one surgeon at our institution. The data including the puncture procedure, access characteristics, access-related complications and stone-free rates were assessed in four sequential groups. The puncture duration and number of times decreased from a mean of 4.4 min and 2.1 times for the first 60 patients to 1.3 min and 1.2 times for the last 60 patients. There was a significant decrease from 3.7 min and 1.8 times for the 61th-120th patients to 1.5 min and 1.3 times for the 121th-180th patients. All of the access-related severe bleeding appeared in the first 120 patients, while perforations only occurred in the first 60 patients. The stone-free rates were 68.3, 83.3, 90.0, and 93.3% for the four sequential groups. The increase in experience lead to an improvement in the puncture duration and times, which accompany with better stone-free rates and lower complications. We propose that 60 operations are sufficient to gain competency, and a cutoff point of 120 operations will allow the surgeon to achieve excellence in the solo US-guided PCNL.

  13. Association of peak factor VIII levels and area under the curve with bleeding in patients with haemophilia A on every third day pharmacokinetic-guided prophylaxis

    NARCIS (Netherlands)

    Valentino, L. A.; Pipe, S. W.; Collins, P. W.; Blanchette, V. S.; Berntorp, E.; Fischer, K.; Ewenstein, B. M.; Oh, M.; Spotts, G.

    2016-01-01

    Introduction: We previously showed that pharmacokinetic-guided prophylaxis (PKP) allows the dosing interval to be extended while maintaining a specific trough level. However, the associations of peak factor VIII (FVIII) levels and area under the curve (AUC) with breakthrough bleeding have not been

  14. Rod cluster control assemblies and rod cluster control guide tubes: wear and drop time

    International Nuclear Information System (INIS)

    Zbinden, M.

    1997-01-01

    The wear of RCCAs and of RCC guide tubes is due to two quite different mechanisms and the remedies to apply for each case might lead to contradictory solutions: - the impact/sliding wear for the seldom moving RCCAs, namely the shutdown RCCAs, under flow-induced vibrations, - the axial sliding wear for the control rods subjected to the stepping movements ordered by the acting load. In this case the hydraulic sticking forces are those which produce an evolution of the surface states that may increase the drop time. The introduction, an historical survey of the encountered difficulties, is followed by short description of the components and then the paper presents contributions of EDF in the R and D field, which take place in two successive multi-annual projects. Lastly, some information is given about the recent evolutions and new problems as well for impact/sliding wear as for drop time under normal or seismic conditions. (author)

  15. Neutron spectrum measurements from a neutron guide tube facility at the ETRR-1 reactor

    Energy Technology Data Exchange (ETDEWEB)

    Maayouf, R M.A.; El-Sayed, L A.A.; El-Kady, A S.I. [Reactor and Neutron Physics Dept., NRC, Atomic Energy Authority, Cairo (Egypt)

    1997-12-31

    The present work deals with measurements of the neutron spectrum emitted from a neutron guide tube (NGT) recently installed at one of the ETRR-1 reactor horizontal channels designed to deliver thermal neutrons, free from fast neutrons and gamma ray background, to a fourier reverse-time-of-flight (RTOF) diffractometer. The measurements were performed using a {sup 6} Li glass scintillation detector combined with a multichannel analyzer set at channel width 4 M sec and installed at 3.4 m from a disc Fermi chopper. Also a theoretical model was specially developed for the neutron spectrum calculations. According to the model developed, the spectrum calculated was found to be in good agreement with the measured one. It was found, both from measurements and calculations, that the spectrum emitted from the NGT covers, after transmission through a fourier chopper, neutron wavelengths from 1-4 A adequate for neutron diffraction measurements at D values between 0.71-2.9 A respectively. 6 FIGS.

  16. Planning of the energetic operation based on storage guide-curves; Planejamento da operacao energetica baseado em curvas-guias de armazenamento

    Energy Technology Data Exchange (ETDEWEB)

    Zambelli, Monica de S.; Cicogna, Marcelo A.; Soares, Secundino [Universidade Estadual de Campinas, SP (Brazil). Faculdade de Engenharia Eletrica

    2006-07-01

    The proposal of this work is to present a long term hydrothermal scheduling operating policy based on the concept of storage guide-curves. According to this policy, at each stage of the planning period the decision of the amount of water to be discharged by each hydrothermal unit must be such that keep its reservoir at levels pre-determined by curves obtained by an optimization method. The performance analysis for this operating policy is given by simulation with historical inflow data, considering a single hydrothermal system, constituted by a single hydro plant, and a composite system, constituted by hydro plants in cascade, adopting as performance criteria the minimization of the expected operating cost. The results demonstrate that, although simple and clear, this operating policy presents a competitive performance in the long term hydrothermal scheduling. (author)

  17. Draft tube flow phenomena across the bulb turbine hill chart

    International Nuclear Information System (INIS)

    Duquesne, P; Fraser, R; Maciel, Y; Aeschlimann, V; Deschênes, C

    2014-01-01

    In the framework of the BulbT project launched by the Consortium on Hydraulic Machines and the LAMH (Hydraulic Machine Laboratory of Laval University) in 2011, an intensive campaign to identify flow phenomena in the draft tube of a model bulb turbine has been done. A special focus was put on the draft tube component since it has a particular importance for recuperation in low head turbines. Particular operating points were chosen to analyse flow phenomena in this component. For each of these operating points, power, efficiency and pressure were measured following the IEC 60193 standard. Visualizations, unsteady wall pressure and efficiency measurements were performed in this component. The unsteady wall pressure was monitored at seven locations in the draft tube. The frequency content of each pressure signal was analyzed in order to characterize the flow phenomena across the efficiency hill chart. Visualizations were recorded with a high speed camera using tufts and cavitation bubbles as markers. The predominant detected phenomena were mapped and categorized in relation to the efficiency hill charts obtained for three runner blade openings. At partial load, the vortex rope was detected and characterized. An inflection in the partial load efficiency curves was found to be related to complex vortex rope instabilities. For overload conditions, the efficiency curves present a sharp drop after the best efficiency point, corresponding to an inflection on the power curves. This break off is more severe towards the highest blade openings. It is correlated to a flow separation at the wall of the draft tube. Also, due to the separation occurring in these conditions, a hysteresis effect was observed on the efficiency curves

  18. Reusable locking tube insertion and removal fixture and method in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a locking tube insertion and removal fixture for use with a reconstitutable fuel assembly. The process includes a top nozzle with an adapter plate having at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having a hollow locking tube insertable and removable into and from a locking position in the upper end portion of the guide thimble for releasably locking the upper end portion of the guide thimble within the passageway of the top nozzle and adapter plate

  19. Investigations of unsteady flow in the draft tube of the pump- turbine model using laser Doppler anemometry

    International Nuclear Information System (INIS)

    Kaznacheev, A; Kuznetsov, I

    2014-01-01

    The measurements and video observation of unsteady flow in the draft tube cone of the pump-turbine model were conducted in the Laboratory of Water Turbines, property of OJSC ''Power machines'' - ''LMZ''. The prototype head was about 250 m. The experiments were performed for the turbine mode of operation. Measurements were taken for the unit speed value n11 corresponding to rated head in the generating mode of operation, for a wide range of guide vanes openings at loads ranging from partial to maximum value. The researches of the velocity field in function of the Thoma number were carried out in some operating conditions. The mean values and RMS deviations of the velocity components were the results of laser measurements. The curves of the intensity of the vortex versus the guide vane opening and the Thoma number were plotted. The energy velocity spectra were presented for the points at which the most pronounced frequency precession of the helical axial vortex was observed. Video recording and laser Doppler anemometry were made in the operating conditions of the developed cavitation. Based on the results of video observations and energy spectra obtained via LDA, vortex frequencies were determined i.e. the frequencies of the vortex precession under the runner in the draft tube cone

  20. Guiding of short, intense laser pulses through solid guides and preformed plasma channels

    International Nuclear Information System (INIS)

    Borghesi, M.; Mackinnon, A.J.; Gaillard, R.; Malka, G.; Vickers, C.; Willi, O.; Blanchot, N.; Miquel, J.L.; Canaud, B.; Davies, J.R.; Malka, G.; Offenberger, A.A.

    2000-01-01

    In a series of experiments carried out at the Rutherford Appleton Laboratory, Chilton (UK) and at the Commissariat a l'Energie Atomique, Limeil (France), various techniques of guiding ultra-intense laser pulses over distances exceeding the natural diffraction length were investigated. Efficient guiding was demonstrated both through density channels formed in an underdense plasma by an intense prepulse and through solid guides (hollow capillary tubes). Indication of collimated fast electron propagation though solid targets has also been obtained. (authors)

  1. Repair boundary for parent tube indications within the upper joint zone of hybrid expansion joint (HEJ) sleeved tubes

    International Nuclear Information System (INIS)

    Cullen, W.K.; Keating, R.F.

    1997-01-01

    In the Spring and Fall of 1994, and the Spring of 1995, crack-like indications were found in the upper hybrid expansion joint (HEJ) region of Steam Generator (S/G) tubes which had been sleeved using Westinghouse HEJ sleeves. As a result of these findings, analytic and test evaluations were performed to assess the effect of the degradation on the structural, and leakage, integrity of the sleeve/tube joint relative to the requirements of the United States Nuclear Regulatory Commission's (NRC) draft Regulatory Guide (RG) 1.121. The results of these evaluations demonstrated that tubes with implied or known crack-like circumferential parent tube indications (PTIs) located 1.1 inches or farther below the bottom of the hardroll upper transition, have sufficient, and significant, integrity relative to the requirements of RG 1.121. Thus, the purpose of this report is to provide background information related to the justification of the modified tube repair boundary

  2. Parsimonious evaluation of concentric-tube continuum robot equilibrium conformation.

    Science.gov (United States)

    Rucker, Daniel Caleb; Webster Iii, Robert J

    2009-09-01

    Dexterous at small diameters, continuum robots consisting of precurved concentric tubes are well-suited for minimally invasive surgery. These active cannulas are actuated by relative translations and rotations applied at the tube bases, which create bending via elastic tube interaction. An accurate kinematic model of cannula shape is required for applications in surgical and other settings. Previous models are limited to circular tube precurvatures, and neglect torsional deformation in curved sections. Recent generalizations account for arbitrary tube preshaping and bending and torsion throughout the cannula, providing differential equations that define cannula shape. In this paper, we show how to simplify these equations using Frenet-Serret frames. An advantage of this approach is the interpretation of torsional components of the preset tube shapes as "forcing functions" on the cannula's differential equations. We also elucidate a process for numerically solving the differential equations, and use it to produce simulations illustrating the implications of torsional deformation and helical tube shapes.

  3. Practical experience in the determination of the tube voltage using the Ardran-Crooks cassette

    International Nuclear Information System (INIS)

    Ewen, K.; Roesner, W.

    1984-01-01

    Within the framework of quality control measures in X-ray diagnostics and therapy, it is desirable to employ for the determination of tube voltage (e.g. in diagnostic X-ray equipment) methods which are as economical as possible while saving time and being simple to apply in spite of the fact that they are as highly accurate as ever possible. The absorber method described here, represented by the Ardran-Crooks cassette, possesses the advantage of low price and easy application. However, if it is operated in such a way that time is saved (assessment by the eye), it is not so accurate, whereas in accurate operation (assessment via luxmeter) it does require a relatively large amount of time. After the film has been exposed, it is necessary to estimate or measure the agreement of blackenings on one and the same film in order to determine the tube voltage. This voltage is then read off by means of a calibration curve. The error in the determination of the tube voltage via the Ardran-Crooks cassette depends on the accuracy of the calibration curve, which, in turn, depends on the number of measurements performed when producing the curve, and on the correct voltage of the standard X-ray equipment used in producing the calibration curve. In addition, assessment by eye adds a total error of 2.3% to 8%, depending on the amount of tube voltage. If the luxmeter is used instead of the eye, this additional error is less than 1% in relation to the magnitude of the tube voltage. (orig./BWU) [de

  4. Survey of the spectral irradiance distribution of fluorescent tubes for solaria

    International Nuclear Information System (INIS)

    Johnsen, B.; Hannevik, M.

    1993-01-01

    The report describes a systematic mapping of the spectral irradiance distribution of typical fluorescent tubes, emitting ultraviolet radiation (UVR). The spectra were multiplied with biological action curves for assessing their potential for acute harmful effects. Comparing values of effective irradiance revealed a difference by a factor of ten between tubes for cosmetic UVR-treatment. Comparing spectra of the strongest cosmetic types with the spectrum of a typical tube for medical UVR-treatment revealed another factor of ten in effective irradiance. Spectra of typical cosmetic solarium tubes and natural sun at summer in Oslo are shown to be closely related in the UV-region, thereby justifying the term artificial sunlamps. Threshold limit values and action curves, as expressed in the former Norwegian solarium prescriptions from 1983 and the CENELEC standard for classifying UVR-emitting appliance, were compared. Calculations have shown that an adoption of the CENELEC threshold limit values will be more restrictive on the short-wave UV-region, while they generally will be similar, or a bit less restrictive on the longwave UV-region. 3 refs., 45 figs., 6 tabs

  5. Corrosion Potential Profile Simulation in a Tube under Cathodic Protection

    Directory of Open Access Journals (Sweden)

    Mauricio Ohanian

    2014-01-01

    Full Text Available The potential distribution in tubes of a heat exchanger is simulated when applying cathodic polarization to its extremes. The comparison of two methods to achieve this goal is presented: a numeric solution based on boundary elements carried out with the commercial software Beasy-GID and a semianalytical method developed by the authors. The mathematical model, the simplifications considered, and the problem solving are shown. Since both approaches use polarization curves as a boundary condition, experimental polarization curves (voltage versus current density were determined in the laboratory under flow conditions and cylindrical cell geometry. The results obtained suggest the impossibility of extending the protection along the whole tube length; therefore, other protection methods are considered.

  6. Dynamic energy conservation model REDUCE. Extension with experience curves, energy efficiency indicators and user's guide

    International Nuclear Information System (INIS)

    Uyterlinde, M.A.; Rijkers, F.A.M.

    1999-12-01

    The main objective of the energy conservation model REDUCE (Reduction of Energy Demand by Utilization of Conservation of Energy) is the evaluation of the effectiveness of economical, financial, institutional, and regulatory measures for improving the rational use of energy in end-use sectors. This report presents the results of additional model development activities, partly based on the first experiences in a previous project. Energy efficiency indicators have been added as an extra tool for output analysis in REDUCE. The methodology is described and some examples are given. The model has been extended with a method for modelling the effects of technical development on production costs, by means of an experience curve. Finally, the report provides a 'users guide', by describing in more detail the input data specification as well as all menus and buttons. 19 refs

  7. Replacement of a photomultiplier tube in a 2-inch thallium-doped sodium iodide gamma spectrometer with silicon photomultipliers and a light guide

    Directory of Open Access Journals (Sweden)

    Chankyu Kim

    2015-06-01

    Full Text Available The thallium-doped sodium iodide [NaI(Tl] scintillation detector is preferred as a gamma spectrometer in many fields because of its general advantages. A silicon photomultiplier (SiPM has recently been developed and its application area has been expanded as an alternative to photomultiplier tubes (PMTs. It has merits such as a low operating voltage, compact size, cheap production cost, and magnetic resonance compatibility. In this study, an array of SiPMs is used to develop an NaI(Tl gamma spectrometer. To maintain detection efficiency, a commercial NaI(Tl 2′ × 2′ scintillator is used, and a light guide is used for the transport and collection of generated photons from the scintillator to the SiPMs without loss. The test light guides were fabricated with polymethyl methacrylate and reflective materials. The gamma spectrometer systems were set up and included light guides. Through a series of measurements, the characteristics of the light guides and the proposed gamma spectrometer were evaluated. Simulation of the light collection was accomplished using the DETECT 97 code (A. Levin, E. Hoskinson, and C. Moison, University of Michigan, USA to analyze the measurement results. The system, which included SiPMs and the light guide, achieved 14.11% full width at half maximum energy resolution at 662 keV.

  8. Superelastic NiTi memory alloy micro-tube under tension - nucleation and propagation of martensite band

    International Nuclear Information System (INIS)

    Li, Z.Q.; Sun, Q.P.

    2000-01-01

    The superelastic behavior of polycrystalline NiTi shape memory alloy micro-tube under tension is studied experimentally. The nominal stress-strain curve of the micro-tube is recorded. By using a special surface coating it is found that the deformation of the tube is via the nucleation and propagation of stress-induced martensite band. The experiments show that the martensite nucleates in the form of a spiral lens-shaped narrow band that is inclined at 61 to the axis of loading when the stress reaches the peak of stress-strain curve. The width and the length of the band grew gradually with increase of loading and finally joined and merged into a single band. The subsequent deformation of the tube is realized by the propagation of this cylindrical martensite band. (orig.)

  9. Flame oscillations in tubes with nonslip at the walls

    Energy Technology Data Exchange (ETDEWEB)

    Akkerman, V' yacheslav; Bychkov, Vitaly; Petchenko, Arkady [Institute of Physics, Umeaa University, SE-901 87 Umeaa (Sweden); Eriksson, Lars-Erik [Department of Applied Mechanics, Chalmers University of Technology, 412 96 Goeteborg (Sweden)

    2006-06-15

    A laminar premixed flame front propagating in a two-dimensional tube is considered with nonslip at the walls and with both ends open. The problem of flame propagation is solved using direct numerical simulations of the complete set of hydrodynamic equations including thermal conduction, diffusion, viscosity, and chemical kinetics. As a result, it is shown that flame interaction with the walls leads to the oscillating regime of burning. The oscillations involve variations of the curved flame shape and the velocity of flame propagation. The oscillation parameters depend on the characteristic tube width, which controls the Reynolds number of the flow. In narrow tubes the oscillations are rather weak, while in wider tubes they become stronger with well-pronounced nonlinear effects. The period of oscillations increases for wider tubes, while the average flame length scaled by the tube diameter decreases only slightly with increasing tube width. The average flame length calculated in the present work is in agreement with that obtained in the experiments. Numerical results reduce the gap between the theory of turbulent flames and the experiments on turbulent combustion in tubes. (author)

  10. Gel spinning of silk tubes for tissue engineering

    Science.gov (United States)

    Lovett, Michael; Cannizzaro, Christopher; Vunjak-Novakovic, Gordana; Kaplan, David L.

    2011-01-01

    Tubular vessels for tissue engineering are typically fabricated using a molding, dipping, or electrospinning technique. While these techniques provide some control over inner and outer diameters of the tube, they lack the ability to align the polymers or fibers of interest throughout the tube. This is an important aspect of biomaterial composite structure and function for mechanical and biological impact of tissue outcomes. We present a novel aqueous process system to spin tubes from biopolymers and proteins such as silk fibroin. Using silk as an example, this method of winding an aqueous solution around a reciprocating rotating mandrel offers substantial improvement in the control of the tube properties, specifically with regard to winding pattern, tube porosity, and composite features. Silk tube properties are further controlled via different post-spinning processing mechanisms such as methanol-treatment, air-drying, and lyophilization. This approach to tubular scaffold manufacture offers numerous tissue engineering applications such as complex composite biomaterial matrices, blood vessel grafts and nerve guides, among others. PMID:18801570

  11. Retrograde Intubation in Temporomandibular Joint Ankylosis-A Double Guide Wire Technique

    Directory of Open Access Journals (Sweden)

    Vitha K Dhulkhed

    2008-01-01

    Full Text Available Intubating a patient with temporomandibular joint ankylosis is always a challenge particularly when fibreoptic laryngo-scope is not available. In a 20-year-old male patient we successfully carried out endotracheal intubation with 7 mm portex cuffed PVC tube with the help of two flexible J tipped guide wires. One guide wire was passed into the airway from cricothyroid puncture site and another from subcricoid site. Both were brought out through the nose. The first guide wire was used for retracting the epiglottis and the second as a guide for passing the endotracheal tube.

  12. Two-dimensional mapping of needle visibility with linear and curved array for ultrasound-guided interventional procedure

    Science.gov (United States)

    Susanti, Hesty; Suprijanto, Kurniadi, Deddy

    2018-02-01

    Needle visibility in ultrasound-guided technique has been a crucial factor for successful interventional procedure. It has been affected by several factors, i.e. puncture depth, insertion angle, needle size and material, and imaging technology. The influences of those factors made the needle not always well visible. 20 G needles of 15 cm length (Nano Line, facet) were inserted into water bath with variation of insertion angles and depths. Ultrasound measurements are performed with BK-Medical Flex Focus 800 using 12 MHz linear array and 5 MHz curved array in Ultrasound Guided Regional Anesthesia mode. We propose 3 criteria to evaluate needle visibility, i.e. maximum intensity, mean intensity, and the ratio between minimum and maximum intensity. Those criteria were then depicted into representative maps for practical purpose. The best criterion candidate for representing the needle visibility was criterion 1. Generally, the appearance pattern of the needle from this criterion was relatively consistent, i.e. for linear array, it was relatively poor visibility in the middle part of the shaft, while for curved array, it is relatively better visible toward the end of the shaft. With further investigations, for example with the use of tissue-mimicking phantom, the representative maps can be built for future practical purpose, i.e. as a tool for clinicians to ensure better needle placement in clinical application. It will help them to avoid the "dead" area where the needle is not well visible, so it can reduce the risks of vital structures traversing and the number of required insertion, resulting in less patient morbidity. Those simple criteria and representative maps can be utilized to evaluate general visibility patterns of the needle in vast range of needle types and sizes in different insertion media. This information is also important as an early investigation for future research of needle visibility improvement, i.e. the development of beamforming strategies and

  13. Improved drainage with active chest tube clearance.

    Science.gov (United States)

    Shiose, Akira; Takaseya, Tohru; Fumoto, Hideyuki; Arakawa, Yoko; Horai, Tetsuya; Boyle, Edward M; Gillinov, A Marc; Fukamachi, Kiyotaka

    2010-05-01

    This study was performed to evaluate the efficacy of a novel chest drainage system. This system employs guide wire-based active chest tube clearance to improve drainage and maintain patency. A 32 Fr chest tube was inserted into pleural cavities of five pigs. On the left, a tube was connected to the chest canister, and on the right, the new system was inserted between the chest tube and chest canister. Acute bleeding was mimicked by periodic infusion of blood. The amount of blood drained from each chest cavity was recorded every 15 min for 2 h. After completion of the procedure, all residual blood and clots in each chest cavity were assessed. The new system remained widely patent, and the amount of drainage achieved with this system (670+/-105 ml) was significantly (P=0.01) higher than that with the standard tube (239+/-131 ml). The amount of retained pleural blood and clots with this system (150+/-107 ml) was significantly (P=0.04) lower than that with the standard tube (571+/-248 ml). In conclusion, a novel chest drainage system with active tube clearance significantly improved drainage without tube manipulations. 2010 Published by European Association for Cardio-Thoracic Surgery. All rights reserved.

  14. Origami tubes with reconfigurable polygonal cross-sections.

    Science.gov (United States)

    Filipov, E T; Paulino, G H; Tachi, T

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings.

  15. Origami tubes with reconfigurable polygonal cross-sections

    Science.gov (United States)

    Filipov, E. T.; Paulino, G. H.; Tachi, T.

    2016-01-01

    Thin sheets can be assembled into origami tubes to create a variety of deployable, reconfigurable and mechanistically unique three-dimensional structures. We introduce and explore origami tubes with polygonal, translational symmetric cross-sections that can reconfigure into numerous geometries. The tubular structures satisfy the mathematical definitions for flat and rigid foldability, meaning that they can fully unfold from a flattened state with deformations occurring only at the fold lines. The tubes do not need to be straight and can be constructed to follow a non-linear curved line when deployed. The cross-section and kinematics of the tubular structures can be reprogrammed by changing the direction of folding at some folds. We discuss the variety of tubular structures that can be conceived and we show limitations that govern the geometric design. We quantify the global stiffness of the origami tubes through eigenvalue and structural analyses and highlight the mechanical characteristics of these systems. The two-scale nature of this work indicates that, from a local viewpoint, the cross-sections of the polygonal tubes are reconfigurable while, from a global viewpoint, deployable tubes of desired shapes are achieved. This class of tubes has potential applications ranging from pipes and micro-robotics to deployable architecture in buildings. PMID:26997894

  16. Fuel bundle to pressure tube fretting in Bruce and Darlington

    Energy Technology Data Exchange (ETDEWEB)

    Norsworthy, A G; Ditschun, A [Atomic Energy of Canada Ltd., Mississauga, ON (Canada)

    1996-12-31

    As the fuel channel elongates due to creep, the fuel string moves relative to the inlet until the fuel pads at the inboard end eventually separate from the spacer sleeve, and the fuel resides on the burnish mark of the pressure tube. The bundle is then supported in a fashion which contributes to increased levels of vibration. Those pads which (due to geometric variation) have contact loads with the pressure tube within a certain range, vibrate, and cause significant fretting on the burnish mark, and further along at the midplane of the bundle. Inspection of the pressure tubes in Bruce A, Bruce B, and Darlington has revealed fret damage up to 0.55 mm at the burnish mark and slightly lower than this at the inlet bundle midplane. To date, all fret marks have been dealt with successfully without the need for tube replacement, but a program of work has been initiated to understand the mechanism and reduce the fretting. Such understanding is necessary to guide future design changes to the fuel bundle, to guide future inspection programs, to guide maintenance programs, and for longer term strategic planning. This paper discusses how the understanding of fretting has evolved and outlines a current hypothesis for the mechanism of fretting. The role of bundle geometry, excitation forces, and reactor conditions are reviewed, along with options under consideration to mitigate damage. (author). 4 refs., 2 tabs., 13 figs.

  17. Fuel bundle to pressure tube fretting in Bruce and Darlington

    International Nuclear Information System (INIS)

    Norsworthy, A.G.; Ditschun, A.

    1995-01-01

    As the fuel channel elongates due to creep, the fuel string moves relative to the inlet until the fuel pads at the inboard end eventually separate from the spacer sleeve, and the fuel resides on the burnish mark of the pressure tube. The bundle is then supported in a fashion which contributes to increased levels of vibration. Those pads which (due to geometric variation) have contact loads with the pressure tube within a certain range, vibrate, and cause significant fretting on the burnish mark, and further along at the midplane of the bundle. Inspection of the pressure tubes in Bruce A, Bruce B, and Darlington has revealed fret damage up to 0.55 mm at the burnish mark and slightly lower than this at the inlet bundle midplane. To date, all fret marks have been dealt with successfully without the need for tube replacement, but a program of work has been initiated to understand the mechanism and reduce the fretting. Such understanding is necessary to guide future design changes to the fuel bundle, to guide future inspection programs, to guide maintenance programs, and for longer term strategic planning. This paper discusses how the understanding of fretting has evolved and outlines a current hypothesis for the mechanism of fretting. The role of bundle geometry, excitation forces, and reactor conditions are reviewed, along with options under consideration to mitigate damage. (author). 4 refs., 2 tabs., 13 figs

  18. Virtually fabricated guide for placement of the C-tube miniplate.

    Science.gov (United States)

    Paek, Janghyun; Jeong, Do-Min; Kim, Yong; Kim, Seong-Hun; Chung, Kyu-Rhim; Nelson, Gerald

    2014-05-01

    This paper introduces a virtually planned and stereolithographically fabricated guiding system that will allow the clinician to plan carefully for the best location of the device and to achieve an accurate position without complications. The scanned data from preoperative dental casts were edited to obtain preoperative 3-dimensional (3D) virtual models of the dentition. After the 3D virtual models were repositioned, the 3D virtual surgical guide was fabricated. A surgical guide was created onscreen, and then these virtual guides were materialized into real ones using the stereolithographic technique. Whereas the previously described guide required laboratory work to be performed by the orthodontist, our technique is more convenient because the laboratory work is done remotely by computer-aided design/computer-aided manufacturing technology. Because the miniplate is firmly held in place as the patient holds his or her mandibular teeth against the occlusal pad of the surgical guide, there is no risk that the miniscrews can slide on the bone surface during placement. The software program (2.5-dimensional software) in this study combines 2-dimensional cephalograms with 3D virtual dental models. This software is an effective and efficient alternative to 3D software when 3D computed tomography data are not available. To confidently and safely place a miniplate with screw fixation, a simple customized guide for an orthodontic miniplate was introduced. The use of a custom-made, rigid guide when placing miniplates will minimize complications such as vertical mislocation or slippage of the miniplate during placement. Copyright © 2014 American Association of Orthodontists. Published by Mosby, Inc. All rights reserved.

  19. Modeling plasma flow in straight and curved solenoids

    International Nuclear Information System (INIS)

    Boercker, D.B.; Sanders, D.M.; Storer, J.; Falabella, S.

    1991-01-01

    The ''flux-tube'' model originated by Morozov is a very simple and numerically efficient method for simulating ion motion in plasma filters. In order to test its utility as a design tool, we compare the predictions of the model to recent experimental measurements of plasma flow in both straight and curved solenoids

  20. Curved wall-jet burner for synthesizing titania and silica nanoparticles

    KAUST Repository

    Ismail, Mohamed; Memon, Nasir; Mansour, Morkous S.; Anjum, Dalaver H.; Chung, Suk-Ho

    2015-01-01

    A novel curved wall-jet (CWJ) burner was designed for flame synthesis, by injecting precursors through a center tube and by supplying fuel/air mixtures as an annular-inward jet for rapid mixing of the precursors in the reaction zone. Titanium

  1. Equilibrium Conformations of Concentric-tube Continuum Robots.

    Science.gov (United States)

    Rucker, D Caleb; Webster, Robert J; Chirikjian, Gregory S; Cowan, Noah J

    2010-09-01

    Robots consisting of several concentric, preshaped, elastic tubes can work dexterously in narrow, constrained, and/or winding spaces, as are commonly found in minimally invasive surgery. Previous models of these "active cannulas" assume piecewise constant precurvature of component tubes and neglect torsion in curved sections of the device. In this paper we develop a new coordinate-free energy formulation that accounts for general preshaping of an arbitrary number of component tubes, and which explicitly includes both bending and torsion throughout the device. We show that previously reported models are special cases of our formulation, and then explore in detail the implications of torsional flexibility for the special case of two tubes. Experiments demonstrate that this framework is more descriptive of physical prototype behavior than previous models; it reduces model prediction error by 82% over the calibrated bending-only model, and 17% over the calibrated transmissional torsion model in a set of experiments.

  2. Endoscopically placed guide wire assisted nasogastric tube insertion for palliation of absolute dysphagia in patients with incurable esophageal cancer

    Directory of Open Access Journals (Sweden)

    Purkayastha Joydeep

    2006-01-01

    Full Text Available Carcinoma of the esophagus is a dreadful disease because it causes a lot of distress to the patient due to its adverse effects on swallowing. Many patients present with large incurable disease or undergo disease progression and become incurable. Such patients are advised palliative and symptomatic care. The most distressing symptom that requires palliation in such patients is dysphagia. Many procedures are available for relief of dysphagia, but these are not readily available or are costly. We describe a simple, safe, cost effective and easy to do procedure for palliation of malignant dysphagia by insertion of Ryle′s tube over a endoscopically placed guide wire especially suitable for patients of the poor socio-economic strata.

  3. Calibration Curve of Neutron Moisture Meter for Sandy Soil under Drip Irrigation System

    International Nuclear Information System (INIS)

    Mohammad, Abd El- Moniem M.; Gendy, R. W.; Bedaiwy, M. N.

    2004-01-01

    The aim of this work is to construct a neutron calibration curve in order to be able to use the neutron probe in sandy soils under drip irrigation systems. The experimental work was conducted at the Soil and Water Department of the Nuclear Research Center, Atomic Energy Authority. Three replicates were used along the lateral lines of the drip irrigation system. For each dripper, ten neutron access tubes were installed to 100-cm depth at distances of 5, 15 and 25 cm from the dripper location around the drippers on the lateral line, as well as between lateral lines. The neutron calibrations were determined at 30, 45, and 60-cm depths. Determining coefficients as well as t-test in pairs were employed to detect the accuracy of the calibrations. Results indicated that in order for the neutron calibration curve to express the whole wet area around the emitter; three-access tubes must be installed at distances of 5, 15, and 25 cm from the emitter. This calibration curve will be correlating the average count ratio (CR) at the studied soil depth of the three locations (5, 15, and 25-cm distances from the emitter) to the average moisture content (θ) for this soil depth of the entire wetted area. This procedure should be repeated at different times in order to obtain different θ and C.R values, so that the regression equation of calibration curve at this soil depth can be obtained. To determine the soil moisture content, the average CR of the three locations must be taken and substituted into the regression equation representing the neutron calibration curve. Results taken from access tubes placed at distances of 15 cm from the emitter, showed good agreement with the average calibration curve both for the 45- and the 60-cm depths, suggesting that the 15-cm distance may provide a suitable substitute for the simultaneous use of the three different distances of 5, 15 and 25 cm. However, the obtained results show also that the neutron calibration curves of the 30-cm depth for

  4. Consequences of pressure tube rupture on in-core components

    International Nuclear Information System (INIS)

    Hill, P.G.; Hauptmann, E.G.; Lee, V.

    1982-12-01

    An investigation has been made of the consequences of pressure tube rupture in calandria vessels of heavy water cooled and moderated reactors. The study included a review of previous experimental and analytical work, as well as supplementary investigations carried out to examine the validity of previous assumptions and findings. The central questions considered were: the possibility of a propagating pressure tube failure; damage to the calandria vessel; and damage to the shut-off-rod guide tubes of the reactor shut-down system. The results of the investigation do not indicate mechanisms of sufficient strength to cause propagating failure in a well-designed, well-operated reactor following a tube burst under normal operating conditions. However, not all the details of the physical processes involved in a tube burst have been revealed by existing experimental and analytical work

  5. The application of ductile-fracture analysis to predictions of pressure-tube failure

    International Nuclear Information System (INIS)

    Simpson, L.A.

    1981-08-01

    Progress during the past six years towards establishing a method for predicting critical crack length in a reactor pressure tube, based on data from tests on small fracture-mechanics specimens, is reviewed. The disadvantages of relying on data from burst tests alone are described along with the benefits of a small-specimen method. It is clear from the work reviewed that only an approach that can account for the ability of the presssure tube material to increase its crack-growth resistance during stable crack extension is suitable for the prediction of critical crack length. A method that utilizes crack-growth resistance curves based on crack-opening displacement, or the J integral, is described, along with a large body of experimental data. It is concluded that the resistance curve approach provides a viable method for the analysis of fracture in pressure tubes that can greatly improve our understanding of the material's behaviour

  6. Handling of radiation emergency involving accidental detachment of 20 Ci iridium-192 source in a guide tube of a radiographic equipment in industrial radiography site

    International Nuclear Information System (INIS)

    Zaparde, S.P.; Murthy, B.K.S.; Vora, V.B.; Subramanian, G.

    1979-01-01

    The source capsule containing about 17.2 Ci of iridium-192 got accidently unscrewed in a guide tube of a gamma radiography equipment while carrying out the radiography of the spiral casing at construction site of a Hydroelectric Power Station. Immediately after the incident about 10 meter distance all around the spiral casing was cordoned off. The unscrewed capsule along with the source pellet was transferred to a lead container by raising the closed end of the guide tube of about 1/2 meters in length. The source pencil cable and cap of source capsule were separated from the source pellet. The source pellet was further shielded by a steel container and lead sheets. The source pellet was reloaded in the source capsule with limited facilities available at the work site. The source capsule cap was perfectly screwed by standing behind the L bench temporarily constructed out of lead sheets for the above jobs. During the above operation, the person received a whole body dose of 2000 mR and extrimety dose of 3000 mR. Handling of one more radiation emergency of similar type is described. A few appliances designed and fabricated for use in such emergencies are briefly described. (auth.)

  7. Thin-walled beam tubes for the SIS. Construction and manufacturing

    International Nuclear Information System (INIS)

    Malwitz, E.

    1985-06-01

    The vacuum system of the SIS consists essentially of torus-shaped vacuum chamber with an annulus-circumference of 216 m which is composed by several beam-tube and chamber elements. In order to reach the desired final pressure of -11 mbar (5 . 10 -9 Pa) a heating of the whole vacuum system to 300 0 C is required. The beam tubes within magnets have regularly an elliptic tube cross section. Within bending magnets the beam tubes are curved in a plane through the large ellipse axis with a bending radius of 10 m. During the development work for the beam tubes within magnets to construction variants were studied until construction maturity. Generally thin-walled beam tubes with elliptic tube cross section are fabricated similarly to spring bellows as corrugated tubes. In this report however beam tubes with elliptic tube cross section are discussed the tube walls of which are smooth and stabilized against the atmospheric pressure by hard-soldered ribs. The report reproduces mainly the most important know how respectively serves as instruction for new constructions. Such beam tubes are planned for the dipole magnets and the quadrupole group consisting of two long quadrupoles, a short quadrupole, and a sextupole. (orig./HSI) [de

  8. From curve fitting to machine learning an illustrative guide to scientific data analysis and computational intelligence

    CERN Document Server

    Zielesny, Achim

    2016-01-01

    This successful book provides in its second edition an interactive and illustrative guide from two-dimensional curve fitting to multidimensional clustering and machine learning with neural networks or support vector machines. Along the way topics like mathematical optimization or evolutionary algorithms are touched. All concepts and ideas are outlined in a clear cut manner with graphically depicted plausibility arguments and a little elementary mathematics. The major topics are extensively outlined with exploratory examples and applications. The primary goal is to be as illustrative as possible without hiding problems and pitfalls but to address them. The character of an illustrative cookbook is complemented with specific sections that address more fundamental questions like the relation between machine learning and human intelligence. All topics are completely demonstrated with the computing platform Mathematica and the Computational Intelligence Packages (CIP), a high-level function library developed with M...

  9. From Curve Fitting to Machine Learning

    CERN Document Server

    Zielesny, Achim

    2011-01-01

    The analysis of experimental data is at heart of science from its beginnings. But it was the advent of digital computers that allowed the execution of highly non-linear and increasingly complex data analysis procedures - methods that were completely unfeasible before. Non-linear curve fitting, clustering and machine learning belong to these modern techniques which are a further step towards computational intelligence. The goal of this book is to provide an interactive and illustrative guide to these topics. It concentrates on the road from two dimensional curve fitting to multidimensional clus

  10. Reflood Heat Transfer in SiC and Graphene Oxide Coated Tube

    International Nuclear Information System (INIS)

    Kim, Kyung Mo; Lee, Seung Won; Bang, In Cheol

    2013-01-01

    The reflood tests have been performed flowing water into bare tube and nanoparticles coated tube at constant flow rate (3 cm/s). The quenching curves have been obtained at atmospheric pressure. Finally, Scanning Electron Microscopy (SEM) images are acquired and contact angles are measured in order to observe the surface structures and wettability effect on cooling performance. The quenching time decreases and quenching velocity increases as the coating time of nanoparticles on the tube increases, because the nanoparticles deposited on the tube destabilize and rupture the vapor film early in the effect of increased Leidenfrost point temperature. The SiC nanoparticles coated tubes have better quenching performance than GO nanoparticles coated tubes. The SEM images and contact angle observations proved the enhanced wettability and rough surface due to deposition of SiC nanoparticles. And the wettability of GO nanoparticles coated tubes shows the increase at 600 s coating. But, the wettability decreases on GO nanoparticles tube coated for 900 s despite the enhanced quenching performance. Thus, the porous structure affects to the better cooling performance in case of GO nanoparticles coated tubes

  11. A Mobile Robotic System for the Inspection and Repair of SG Tubes in NPPs

    Directory of Open Access Journals (Sweden)

    Yong-Chil Seo

    2016-04-01

    Full Text Available The reliability and performance of a steam generator (SG is one of the serious concerns in the operation of pressurized water nuclear power plants. Because of high levels of radiation, robotic systems have been used to inspect and repair SG tubes. In this paper, we present a mobile robotic system that positions the inspection and repair tools while hanging down from the tube sheets where the tubes are fixed. All of the driving mechanisms of the mobile robot are actuated by electric motors to start its works, providing that the electric power is prepared without the additional need for an on-site air services. A special tube-holding mechanism with a high holding force has been developed to prevent falling from the tube sheets, even in the case of an electric power failure. We have also developed a quick installation guide device that guides the mobile robot to desired initial positions in the tube sheet exactly and quickly, which helps to reduce the radiation exposure of human workers during the installation work. This paper also provides on-site experimental results and lessons learned.

  12. Estimation of residual life of boiler tubes using steamside oxide scale thickness

    International Nuclear Information System (INIS)

    Vikrant, K.S.N.; Ramareddy, G.V.; Pavan, A.H.V.; Singh, Kulvir

    2013-01-01

    In thermal power plants, remaining-life-estimation of boiler tubes is required at regular intervals for a safer and a better functionality of boilers. In this paper, a new method is proposed for the residual life estimation of service exposed boiler tubes using Non-Destructive Ultrasonic Oxide scale thickness measurements, average metal temperature and creep master curve. While steady state conduction heat transfer equations are solved to calculate the average metal temperature, creep master curve is generated from short term stress rupture data of rupture life less than 5000 h on a virgin material. In the present study, the residual life of T22 (2.25Cr-1Mo) service exposed Platen Superheater tube is estimated using two master creep curves, i.e. Larson-Miller Parametric (LMP) method of standard ASME T22 creep data and Wilshire approach of short term stress rupture data of T22. As the residual life is calculated from fundamental conduction heat transfer theory and creep rupture data, the proposed method can be applied for different grades of boiler materials. -- Highlights: ► Residual life is calculated from non-destructive oxide scale thickness, creep master curve and average metal temperature. ► A new method is proposed for calculating residual life using above parameters and from conduction heat transfer principles. ► The method can be applied to different boiler grades for estimating residual life and hence the method is generic

  13. The temperature dependence of the tensile properties of thermally treated Alloy 690 tubing

    International Nuclear Information System (INIS)

    Harrod, D.L.; Gold, R.E.; Larsson, B.; Bjoerkman, G.

    1992-01-01

    Tensile tests were run in air on full tube cross-sections of 22.23 mm OD by 1.27 mm wall thickness Alloy 690 steam generator production tubes from ten (10) heats of material at eight (8) temperatures between room temperature and 760 degrees C. The tubing was manufactured to specification requirements consistent with the EPRI guidelines for Alloy 690 tubing. The room temperature stress-strain curves are described quite well by the Voce equation. Ductile fracture by dimpled rupture was observed at all test temperatures. The elevated temperature tensile properties are compared with design data given in the ASME Code

  14. Nondestructive characterization of hydrogen concentration in zircaloy cladding tubes with laser ultrasound technique

    International Nuclear Information System (INIS)

    Yang, Che Hua; Lai, Yu An

    2006-01-01

    This paper describes a laser ultrasound technique (LUT) for nondestructive characterization of hydrogen concentration (HC) in Zircaloy cladding tubes. With the LUT, guided ultrasonic waves are generated remotely and then propagate in the axial direction of Zircaloy tubes, and finally detected remotely by an optical probe. By measuring the dispersion spectra with the LUT, relations between the dispersion spectra and the HC of the Zircaloy tubes can be established. The LUT is non-contact, capable of remote inspection, and therefore suitable for nondestructive inspection of HC in Zircaloy cladding tubes used in nuclear power plant.

  15. Characterizing the active opening of the eustachian tube in a hypobaric/hyperbaric pressure chamber.

    Science.gov (United States)

    Mikolajczak, Stefanie; Meyer, Moritz Friedo; Hahn, Moritz; Korthäuer, Christine; Jumah, Masen Dirk; Hüttenbrink, Karl-Bernd; Grosheva, Maria; Luers, Jan Christoffer; Beutner, Dirk

    2015-01-01

    Active and passive opening of the Eustachian tube (ET) enables direct aeration of the middle ear and a pressure balance between middle ear and the ambient pressure. The aim of this study was to characterize standard values for the opening pressure (ETOP), the opening frequency (ETOF), and the opening duration (ETOD) for active tubal openings (Valsalva maneuver, swallowing) in healthy participants. In a hypobaric/hyperbaric pressure chamber, 30 healthy participants (19 women, 11 men; mean age, 25.57 ± 3.33 years) were exposed to a standardized profile of compression and decompression. The pressure values were recorded via continuous impedance measurement during the Valsalva maneuver and swallowing. Based on the data, standard curves were identified and the ETOP, ETOD, and ETOF were determined. Recurring patterns of the pressure curve during active tube opening for the Valsalva maneuver and for active swallowing were characterized. The mean value for the Valsalva maneuver for ETOP was 41.21 ± 17.38 mbar; for the ETOD, it was 2.65 ± 1.87 seconds. In the active pressure compensation by swallowing, the mean value for the ETOP was 29.91 ± 13.07 mbar; and for the ETOD, it was 0.82 ± 0.53 seconds. Standard values for the opening pressure of the tube and the tube opening duration for active tubal openings (Valsalva maneuver, swallowing) were described, and typical curve gradients for healthy subjects could be shown. This is another step toward analyzing the function of the tube in compression and decompression.

  16. CT-guided interventions in children

    International Nuclear Information System (INIS)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A.

    2007-01-01

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  17. Study on manufacturing technology of fuel guide tube using HANA alloys

    International Nuclear Information System (INIS)

    Kim, Hyungil; Jung, Yangil; Park, Dongjun; Park, Jeongyong; Kim, Ilhyun; Choi, Byungkwon; Jeong, Yonghwan; Park, Sangyoon

    2013-04-01

    This research was focused on the study for the manufacturing technology of HANA alloys to crease the corrosion resistance of 30% as well as the to improve the strength of 10% when compared to the commercial zirconium alloys. The new manufacturing concept having higher corrosion resistance and strength than commercial alloy performance can be obtained in this research. This result was transferred to the KNF and, that will be commercialized. This research result can be summarized like this; Ο Parameter study to increase formability of HANA alloy tube - Study on alloy element and heat-treatment effect - Study on texture development mechanism - Study on final annealing effect Ο Out-of-pile performance evaluation of HANA alloy tube - Corrosion performance evaluation of HANA alloy manufactured at KNF - Mechanical performance evaluation of HANA alloy manufactured at KNF - Recrystallization behavior evaluation of HANA alloy manufactured at KNF - Texture characterization of HANA alloy manufactured at KNF - Microstructure characterization of HANA alloy manufactured at KNF Ο Manufacturing guideline setup to increase formability of HANA alloy tube - Manufacturing guideline setup to decrease surface defect - Manufacturing guideline setup to increase strength and corrosion resistance - Manufacturing guideline setup to control texture

  18. Wave-guide type photo reactor for water purification

    International Nuclear Information System (INIS)

    Nobuaki, Negishi; Feng, He; Sadao, Matsuzawa; Koji, Takeuchi; Kayo, Ohno

    2006-01-01

    A wave-guide type photo-catalytic rod that is consisting of a glass tube with transparent TiO 2 (outside) and an optical wave-guide rod (inside) was designed and examined its performance. A model of polluted water, which contains 100 ppm of toluene or phenol, was taken in a 500 ml of beaker and the performance of this unit was evaluated by the removal rate of pollutants in water under photo-irradiation. Acrylic rod with 6-mm diameter was used as the wave-guide of light. One end of acrylic rod 50 mm had a frosted part or a screw thread for increasing seep out of the light. For the glass tube with transparent TiO 2 , four kinds with different film thickness were prepared by the dip-coating method. The wave-guide type photo-catalytic rods effectively eliminated toluene and phenol and the total amount of intermediates formation was low. (authors)

  19. Reusable locking tube in a reconstitutable fuel assembly

    International Nuclear Information System (INIS)

    Shallenberger, J.M.; Ferlan, S.J.

    1987-01-01

    This patent describes a reconstitutable fuel assembly including a top nozzle with an adapter plate having an interior wall forming at least one passageway, at least one guide thimble with an upper end portion, and an attaching structure having an outer socket formed by a circumferential groove defined in the adapter plate passageway wall and opening into the passageway and an inner socket formed by a circumferential bulge and at least one longitudinal slot defined in the upper end portion of the guide thimble. The circumferential bulge is capable of seating within the circumferential groove, an improved reusable tube for releasably locking the inner socket of the guide thimble upper end portion in locking engagement within the outer socket of the adapter plate passageway when the circumferential bulge is seated within the circumferential groove. The reusable tube comprises: (a) an elongated hollow tubular body capable of insertion within the adapter plate passageway and guide thimble upper end portion to a locking position therein such that the circumferential bulge of the inner socket is maintained seated in the locking engagement with the circumferential groove of the outer socket; and (b) at least a pair of dimples performed on the exterior of the tubular body prior to insertion of the body in the guide thimble upper end portion and to the locking position, the dimples being performed and configured to increase the thickness of the tubular body in relation to the remainder of the tubular body. The dimples are substantially resisting resilient yielding in relation to the remainder of the tubular body

  20. Pitot-tube turbine as wind power plant

    Energy Technology Data Exchange (ETDEWEB)

    Naake, L

    1978-10-19

    The use of the Pitot tube turbine as a wind power station is an application of the well known Pitot tube with the turbines built into jet engines. The novelty of this invention lies in the combined nozzle and turbine unit, where the wind is caught in the funnel opening, is accelerated in the narrow flow zone and then acts on the turbine blades. Due to the acceleration, a greater torque is exerted on the turbine than in free air flow. The Pitot tube turbine consists of a casing with a turbine inside, which is fixed by guide vane supports to the casing and which contains one or two stage turbine blades and electrical generators. The whole structure with the rotor is set on a sub-frame and rotation is contained by control surfaces. The subframe can be used as a building.

  1. Characteristics of Pilger Die Materials for Nuclear Zirconium Alloy Tubes

    International Nuclear Information System (INIS)

    Park, Ki Bum; Kim, In Kyu; Park, Min Young; Kahng, Jong Yeol; Kim, Sun Doo

    2011-01-01

    KEPCO Nuclear Fuel Company's (KEPCO NF) tube manufacturing facility, Techno Special Alloy (TSA) Plant, has started cold pilgering operation since 2008. It is obvious that the cold pilgering process is one of the key processes controlling the quality and the characteristics of the tubes manufactured, i.e. nuclear zirconium alloy tube in KEPCO NF. Cold pilgering is a rolling process for forming metal tubes in which diameter and wall thickness are reduced in a number of forming steps, using ring dies at outside of the tube and a curved mandrel at inside to reduce tube cross sections by up to 90 percent. The OD size of tube is reduced by a pair of dies, and ID size and wall thickness is controlled simultaneously by mandrel. During the cold pilgering process, both tools are the critical components for providing qualified tube. Development of pilger die and mandrel has been a significant importance in the zirconium tube manufacturing and a major goal of KEPCO NF. The objective of this study is to evaluate the life time of pilger die during pilgering. Therefore, a comparison of the heat treatment and mechanical properties of between AISI 52100 and AISI H13 materials was made in this study

  2. Surgeon Design Interface for Patient-Specific Concentric Tube Robots.

    Science.gov (United States)

    Morimoto, Tania K; Greer, Joseph D; Hsieh, Michael H; Okamura, Allison M

    2016-06-01

    Concentric tube robots have potential for use in a wide variety of surgical procedures due to their small size, dexterity, and ability to move in highly curved paths. Unlike most existing clinical robots, the design of these robots can be developed and manufactured on a patient- and procedure-specific basis. The design of concentric tube robots typically requires significant computation and optimization, and it remains unclear how the surgeon should be involved. We propose to use a virtual reality-based design environment for surgeons to easily and intuitively visualize and design a set of concentric tube robots for a specific patient and procedure. In this paper, we describe a novel patient-specific design process in the context of the virtual reality interface. We also show a resulting concentric tube robot design, created by a pediatric urologist to access a kidney stone in a pediatric patient.

  3. Fatigue testing on samples from Zircaloy-4 tubes type SEU-43

    International Nuclear Information System (INIS)

    Olaru, V.; Ionescu, V.; Nitu, A.; Ionescu, D.; Voicu, F.

    2016-01-01

    The paper presents the testing of samples worked from Zicaloy-4 tubes (as-received.. metallurgical state), utilized in the composition of the CANDU SEU-43 fuel bundle. These tests are intended to simulate their behaviour in a power cycling process inside the reactor. The testing process is of low cycle fatigue type, done outside of the reactor, on ''C-ring'' samples, cut along the transversal direction. These samples are tested at 1%, 2% and 3% amplitude deformation, at room temperature. The calibration curves for both types of tube (small and big diameter) are determined by using the finite element analyses with the ANSYS computer code. The cycling test results are in the form of a fatigue life curve (N-e) for zircaloy-4 used in the SEU-43 fuel bundle. The curve is determined by the experimental dependency between the number of cycles to fracture and the deformation amplitude. The low cycle fatigue mechanical tests done at room temperature together with electronic microscopy analyses have reflected the characteristic behaviour of the zircaloy-4 metal in the given environment conditions. (authors)

  4. A survey on the corrosion susceptibility of Alloy 800 CANDU steam generator tubing materials

    International Nuclear Information System (INIS)

    Lu, Y.C.; Dupuis, M.; Burns, D.

    2008-01-01

    To provide support for a proactive steam generator (SG) aging management strategy, a survey on the corrosion susceptibility of the archived Alloy 800 tubing from CANDU SGs under plausible crevice chemistry conditions was conducted to assess the potential material degradation issues in CANDU SGs. Archived Alloy 800 samples were collected from four CANDU utilities. High-temperature electrochemical analysis was carried out to assess the corrosion susceptibility of the archived SG tubing under simulated CANDU crevice chemistry conditions at both 150 o C and 300 o C. The potentiodynamic polarization results obtained from the archived CANDU SG tubes were compared to the data from ex-service tubes removed from Darlington Nuclear Generating Station (DNGS) SGs and a reference nuclear grade Alloy 800 tubing. It was found that the removed Darlington SG tubes, with signs of in-service degradation, were more susceptible to pitting corrosion than the reference nuclear grade Alloy 800 tubing. At 150 o C, under the same neutral crevice chemistry conditions, the potentiodynamic polarization curve of the ex-service Darlington SG tubing has an active peak, which is a sign of propensity to crevice/underdeposit corrosion. This active peak was not observed in any of the potentiodynamic polarization curves of all archived Alloy 800 CANDU SG tubing indicating that archived CANDU SG tubes are less susceptible to the underdeposit corrosion under SG startup conditions. The corrosion behaviour of the archived Alloy 800 tubes from CANDU SG was similar to that of the reference nuclear grade Alloy 800 tubing. The results of this survey suggest that the Alloy 800 tubing materials used in the existing CANDU utilities (other than ex-service DNGS tubing) will continue to have reliable performance under specified CANDU operating conditions. Ex-service SG tubing from DNGS, although showing lower than average corrosion resistance, still has a wide acceptable operating margin and the in

  5. Effect of cyclic loading on the viscoplastic behaviour of Zircaloy 4 cladding tubes

    International Nuclear Information System (INIS)

    Bouffioux, P.; Gabriel, B.; Soniak, A.; Mardon, J.P.

    1995-06-01

    Most of the electricity being generated by nuclear energy load follow and remote control have become normal operating modes in the French PWR. In addition, EDF is developing a strategy of fuel sub-assembly burnup extension. Those operating conditions will lead to cyclic straining of the Zircaloy cladding tube which could induce damages. Therefore, EDF, CEA, and FRAMATOME has started a joint R and D cooperative program in order to investigate the mechanical behaviour of Zircaloy cladding tubes under cyclic loading. This paper is dealing with the effect of a pre-cyclic loading on the plasticity properties of Zircaloy 4 cladding tubes. Load controlled cyclic tests were carried out at 350 deg. C and 0.5 Hz in both axial and hoop directions. The Woehler curves were determined. Sequential tests combining pre-cyclic loading to 50 and 75 % fraction life with tension were then performed. It has ben noticed that the pre-cycling loading does not change the plastic flow curve of the Zircaloy 4 cladding tubes and therefore does not induce observable macroscopic damage. It has been concluded that a linear cumulative damage rule like ΣΔN(σ)/N r(σ) is very conservative. (author)

  6. Section curve reconstruction and mean-camber curve extraction of a point-sampled blade surface.

    Directory of Open Access Journals (Sweden)

    Wen-long Li

    Full Text Available The blade is one of the most critical parts of an aviation engine, and a small change in the blade geometry may significantly affect the dynamics performance of the aviation engine. Rapid advancements in 3D scanning techniques have enabled the inspection of the blade shape using a dense and accurate point cloud. This paper proposes a new method to achieving two common tasks in blade inspection: section curve reconstruction and mean-camber curve extraction with the representation of a point cloud. The mathematical morphology is expanded and applied to restrain the effect of the measuring defects and generate an ordered sequence of 2D measured points in the section plane. Then, the energy and distance are minimized to iteratively smoothen the measured points, approximate the section curve and extract the mean-camber curve. In addition, a turbine blade is machined and scanned to observe the curvature variation, energy variation and approximation error, which demonstrates the availability of the proposed method. The proposed method is simple to implement and can be applied in aviation casting-blade finish inspection, large forging-blade allowance inspection and visual-guided robot grinding localization.

  7. A compact large-format streak tube for imaging lidar

    Science.gov (United States)

    Hui, Dandan; Luo, Duan; Tian, Liping; Lu, Yu; Chen, Ping; Wang, Junfeng; Sai, Xiaofeng; Wen, Wenlong; Wang, Xing; Xin, Liwei; Zhao, Wei; Tian, Jinshou

    2018-04-01

    The streak tubes with a large effective photocathode area, large effective phosphor screen area, and high photocathode radiant sensitivity are essential for improving the field of view, depth of field, and detectable range of the multiple-slit streak tube imaging lidar. In this paper, a high spatial resolution, large photocathode area, and compact meshless streak tube with a spherically curved cathode and screen is designed and tested. Its spatial resolution reaches 20 lp/mm over the entire Φ28 mm photocathode working area, and the simulated physical temporal resolution is better than 30 ps. The temporal distortion in our large-format streak tube, which is shown to be a non-negligible factor, has a minimum value as the radius of curvature of the photocathode varies. Furthermore, the photocathode radiant sensitivity and radiant power gain reach 41 mA/W and 18.4 at the wavelength of 550 nm, respectively. Most importantly, the external dimensions of our streak tube are no more than Φ60 mm × 110 mm.

  8. Gastrostomy Tube (G-Tube)

    Science.gov (United States)

    ... any of these problems: a dislodged tube a blocked or clogged tube any signs of infection (including redness, swelling, or warmth at the tube site; discharge that's yellow, green, or foul-smelling; fever) excessive bleeding or drainage from the tube site severe abdominal pain lasting ...

  9. THE CHANDRA VARIABLE GUIDE STAR CATALOG

    International Nuclear Information System (INIS)

    Nichols, Joy S.; Lauer, Jennifer L.; Morgan, Douglas L.; Sundheim, Beth A.; Henden, Arne A.; Huenemoerder, David P.; Martin, Eric

    2010-01-01

    Variable stars have been identified among the optical-wavelength light curves of guide stars used for pointing control of the Chandra X-ray Observatory. We present a catalog of these variable stars along with their light curves and ancillary data. Variability was detected to a lower limit of 0.02 mag amplitude in the 4000-10000 A range using the photometrically stable Aspect Camera on board the Chandra spacecraft. The Chandra Variable Guide Star Catalog (VGUIDE) contains 827 stars, of which 586 are classified as definitely variable and 241 are identified as possibly variable. Of the 586 definite variable stars, we believe 319 are new variable star identifications. Types of variables in the catalog include eclipsing binaries, pulsating stars, and rotating stars. The variability was detected during the course of normal verification of each Chandra pointing and results from analysis of over 75,000 guide star light curves from the Chandra mission. The VGUIDE catalog represents data from only about 9 years of the Chandra mission. Future releases of VGUIDE will include newly identified variable guide stars as the mission proceeds. An important advantage of the use of space data to identify and analyze variable stars is the relatively long observations that are available. The Chandra orbit allows for observations up to 2 days in length. Also, guide stars were often used multiple times for Chandra observations, so many of the stars in the VGUIDE catalog have multiple light curves available from various times in the mission. The catalog is presented as both online data associated with this paper and as a public Web interface. Light curves with data at the instrumental time resolution of about 2 s, overplotted with the data binned at 1 ks, can be viewed on the public Web interface and downloaded for further analysis. VGUIDE is a unique project using data collected during the mission that would otherwise be ignored. The stars available for use as Chandra guide stars are

  10. Probe-holding apparatus for holding a probe for checking steam generator tubes particularly in a nuclear reactor installation

    International Nuclear Information System (INIS)

    Adamowski, A.; Gagny; Gallet, G.; Lhermitte, J.; Monne, M.; Vautherot, G.

    1984-01-01

    Probe-holding apparatus for holding a probe for checking steam generator tubes particularly in a nuclear reactor installation. The apparatus comprises a telescopic arm supported via a ball and socket joint from a support mounted in or near an access aperture in a chamber at one end of the steam generator. A probe guide is carried by a carriage pivotally mounted at the other end of the telescopic arm. The carriage includes an endless belt having a series of spaced projections which engage into the ends of the tubes, the projections being spaced by a distance equal to the tube pitch or a multiple thereof. The belt is driven by a stepping motor in order to move the carriage and place the probe guide opposite different ones of the tubes

  11. A statistical approach to the prediction of pressure tube fracture toughness

    International Nuclear Information System (INIS)

    Pandey, M.D.; Radford, D.D.

    2008-01-01

    The fracture toughness of the zirconium alloy (Zr-2.5Nb) is an important parameter in determining the flaw tolerance for operation of pressure tubes in a nuclear reactor. Fracture toughness data have been generated by performing rising pressure burst tests on sections of pressure tubes removed from operating reactors. The test data were used to generate a lower-bound fracture toughness curve, which is used in defining the operational limits of pressure tubes. The paper presents a comprehensive statistical analysis of burst test data and develops a multivariate statistical model to relate toughness with material chemistry, mechanical properties, and operational history. The proposed model can be useful in predicting fracture toughness of specific in-service pressure tubes, thereby minimizing conservatism associated with a generic lower-bound approach

  12. Sensitivity of the magnetization curves of different austenitic stainless tube and pipe steels to mechanical fatigue

    International Nuclear Information System (INIS)

    Niffenegger, M.; Leber, H.J.

    2008-01-01

    In meta-stable austenitic stainless steels, fatigue is accompanied by a partial strain-induced transformation of paramagnetic austenite to ferromagnetic martensite [G.B. Olsen, M. Cohen, Kinetics of strain induced martensite nucleation, Metall. Trans. 6 (1975) 791-795]. The associated changes of magnetic properties as the eddy current impedance, magnetic permeability or the remanence field may serve as an indication for the degree of fatigue and therefore the remaining lifetime of a component, even though the exact causal relationship between martensite formation and fatigue is not fully understood. However, measuring these properties by magnetic methods may be limited by the low affinity for strain-induced martensite formation. Thus other methods have to be found which are able to detect very small changes of ferromagnetic contents. With this aim the influence of cyclic strain loading on the magnetization curves of the austenitic stainless tube and pipe steels TP 321, 347, 304L and 316L is analysed in the present paper. The measured characteristic magnetic properties, which are the saturation magnetization, residual magnetization, coercive field and the field dependent permeability (AC-magnetization), are sensitive to fatigue and the corresponding material changes (martensitic transformation). In particular, the AC-magnetization was found to be very sensitive to small changes of the amount of strain induced martensite and therefore also to the degree of fatigue. Hence we conclude that applying magnetic minor loops are promising for the non-destructive evaluation of fatigue in austenitic stainless steel, even if a very small amount of strain induced martensite is formed

  13. Tube in zirconium base alloy for nuclear fuel assembly and manufacturing process of such a tube

    International Nuclear Information System (INIS)

    Mardon, J.P.; Senevat, J.; Charquet, D.

    1996-01-01

    This patent concerns the description and manufacturing guidelines of a zirconium alloy tube for fuel cladding or fuel assembly guiding. The alloy contains (in weight) 0.4 to 0.6% of tin, 0.5 to 0.8% of iron, 0.35 to 0.50% of vanadium and 0.1 to 0.18% of oxygen. The carbon and silicon tenors range from 100 to 180 ppm and from 80 to 120 ppm, respectively. The alloy contains only zirconium, plus inevitable impurities, and is completely recrystallized. Corrosion resistance tests were performed on tubes made of this alloy and compared to corrosion tests performed on zircaloy 4 tubes. These tests show a better corrosion resistance and a lower corrosion kinetics for the new alloy, even in presence of lithium and iodine, and a lower hydridation rate. The mechanical resistance of this alloy is slightly lower than the one of zircaloy 4 but becomes equivalent or slightly better after two irradiation cycles. The ductility remains always equal or better than for zircaloy 4. (J.S.)

  14. CT fluoroscopy-guided vs. multislice CT biopsy mode-guided lung biopsies: Accuracy, complications and radiation dose

    International Nuclear Information System (INIS)

    Prosch, Helmut; Stadler, Alfred; Schilling, Matthias; Bürklin, Sandra; Eisenhuber, Edith; Schober, Ewald; Mostbeck, Gerhard

    2012-01-01

    Background: The aim of this retrospective study was to compare the diagnostic accuracy, the frequency of complications, the duration of the interventions and the radiation doses of CT fluoroscopy (CTF) guided biopsies of lung lesions with those of multislice CT (MS-CT) biopsy mode-guided biopsies. Methods: Data and images from 124 consecutive patients undergoing CTF-guided lung biopsy (group A) and 132 MS-CT-biopsy mode-guided lung biopsy (group B) were reviewed. CTF-guided biopsies were performed on a Siemens Emotion 6 CT scanner with intermittent or continuous CT-fluoroscopy, MS-CT biopsy mode-guided biopsies were performed on a Siemens Emotion 16 CT scanner. All biopsies were performed with a coaxial needle technique. Results: The two groups (A vs. B) did not differ significantly regarding sensitivity (95.5% vs. 95.9%), specificity (96.7% vs. 95.5%), negative predictive value (87.9% vs. 84%) or positive predictive value (98.8% vs. 98.9%). Pneumothorax was observed in 30.0% and 32.5% of the patients, respectively. Chest tube placement was necessary in 4% (group A) and 13% (group B) of the patients. The duration of the intervention was significantly longer in group A (median 37 min vs. 32 min, p = 0.04). The mean CT dose index (CTDI) was 422 in group A and 36.3 in group B (p < 0.001). Conclusion: Compared to CTF-guided biopsies, chest biopsies using the MS-CT biopsy mode show dramatically lower CTDI levels. Although the diagnostic yield of the procedures do not differ significantly, biopsies using the MS-CT-biopsy mode have a three-fold higher rate of chest tube placement.

  15. Use of the cumulative sum method (CUSUM) to assess the learning curves of ultrasound-guided continuous femoral nerve block.

    Science.gov (United States)

    Kollmann-Camaiora, A; Brogly, N; Alsina, E; Gilsanz, F

    2017-10-01

    Although ultrasound is a basic competence for anaesthesia residents (AR) there is few data available on the learning process. This prospective observational study aims to assess the learning process of ultrasound-guided continuous femoral nerve block and to determine the number of procedures that a resident would need to perform in order to reach proficiency using the cumulative sum (CUSUM) method. We recruited 19 AR without previous experience. Learning curves were constructed using the CUSUM method for ultrasound-guided continuous femoral nerve block considering 2 success criteria: a decrease of pain score>2 in a [0-10] scale after 15minutes, and time required to perform it. We analyse data from 17 AR for a total of 237 ultrasound-guided continuous femoral nerve blocks. 8/17 AR became proficient for pain relief, however all the AR who did more than 12 blocks (8/8) became proficient. As for time of performance 5/17 of AR achieved the objective of 12minutes, however all the AR who did more than 20 blocks (4/4) achieved it. The number of procedures needed to achieve proficiency seems to be 12, however it takes more procedures to reduce performance time. The CUSUM methodology could be useful in training programs to allow early interventions in case of repeated failures, and develop competence-based curriculum. Copyright © 2017 Sociedad Española de Anestesiología, Reanimación y Terapéutica del Dolor. Publicado por Elsevier España, S.L.U. All rights reserved.

  16. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose- effect curve)

    International Nuclear Information System (INIS)

    Al Achkar, W.

    2002-01-01

    In order to draw a dose-effect curve, blood from eight healthy people were studied. Samples were irradiated in tubes with 0.15-2.5 gray of gamma ray.Irradiated and control samples were incubated for cell cultures. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics+ rings and total numbers of breaks were drawn. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  17. A RVI/LAI-reference curve to detect N stress and guide N fertigation using combined information from spectral reflectance and leaf area measurements in potato

    DEFF Research Database (Denmark)

    Zhenjiang, Zhou; Plauborg, Finn; Thomsen, Anton Gårde

    2017-01-01

    More user-friendly methods are needed to detect crop N status/stress and guide the timing of in-season N application. In the current study, a reference curve method of detecting N stress was proposed to remedy practical problems of methods that require leaf sampling or maintaining a N sufficient...... was applied during the season. The total N ranged from 0 to180 kg N ha−1. RVI and LAI from the economically optimum 180 kg N ha−1 treatments were used to derive the reference curve. RVI and LAI from 180 kg N ha−1 treatment had a high (R2 = 0.97) correlation and were best fitted with a 2nd order polynomial...... function, which was independent of season. The treatments where N fertigation was stopped before reaching 180 kg N ha−1 started to deviate from the 95% confidence interval of the reference curve about 10 days after N-fertigation was stopped. This corresponded to 10–20 kg ha−1 difference in total plant N...

  18. A twisted flux-tube model for solar prominences. I. General properties

    International Nuclear Information System (INIS)

    Priest, E.R.; Hood, A.W.; Anzer, U.

    1989-01-01

    It is proposed that a solar prominence consists of cool plasma supported in a large-scale curved and twisted magnetic flux tube. As long as the flux tube is untwisted, its curvature is concave toward the solar surface, and so it cannot support dense plasma against gravity. However, when it is twisted sufficiently, individual field lines may acquire a convex curvature near their summits and so provide support. Cool plasma then naturally tends to accumulate in such field line dips either by injection from below or by thermal condensation. As the tube is twisted up further or reconnection takes place below the prominence, one finds a transition from normal to inverse polarity. When the flux tube becomes too long or is twisted too much, it loses stability and its true magnetic geometry as an erupting prominence is revealed more clearly. 56 refs

  19. Experimental Study of Concrete-filled Carbon Fiber Reinforced Polymer Tube with Internal Reinforcement under Axially Loading

    Directory of Open Access Journals (Sweden)

    Wenbin SUN

    2014-12-01

    Full Text Available Comparing with the circular concrete columns confined with fiber reinforced polymer (FRP wrap or tube, the rectilinear confined columns were reported much less. Due to the non-uniform distribution of confining pressure in the rectilinear confined columns, the FRP confinement effectiveness was significant reduced. This paper presents findings of an experimental program where nine prefabricated rectangular cross-section CFRP tubes with CFRP integrated crossties filled concrete to form concrete-filled FRP tube (CFFT short columns and three plain concrete control specimens were tested. All specimens were axially loaded until failure. The rest results showed that the stress-strain curves of CFFTs consisted of two distinct branches, an ascending branch before the concrete peak stress was reaches and a second branch that terminated when the tube ruptured, and that the CFFTs with integrated crossties experienced most uniform confinement pressure distribution. Test research also found that the stress-strain curves of CFFTs indicated an increase in ductility. These demonstrate that this confinement system can produce higher lateral confinement stiffness. DOI: http://dx.doi.org/10.5755/j01.ms.20.4.6035

  20. Aerodynamic calculational methods for curved-blade Darrieus VAWT WECS

    Science.gov (United States)

    Templin, R. J.

    1985-03-01

    Calculation of aerodynamic performance and load distributions for curved-blade wind turbines is discussed. Double multiple stream tube theory, and the uncertainties that remain in further developing adequate methods are considered. The lack of relevant airfoil data at high Reynolds numbers and high angles of attack, and doubts concerning the accuracy of models of dynamic stall are underlined. Wind tunnel tests of blade airbrake configurations are summarized.

  1. Estimation of optimal nasotracheal tube depth in adult patients.

    Science.gov (United States)

    Ji, Sung-Mi

    2017-12-01

    The aim of this study was to estimate the optimal depth of nasotracheal tube placement. We enrolled 110 patients scheduled to undergo oral and maxillofacial surgery, requiring nasotracheal intubation. After intubation, the depth of tube insertion was measured. The neck circumference and distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch were measured. To estimate optimal tube depth, correlation and regression analyses were performed using clinical and anthropometric parameters. The mean tube depth was 28.9 ± 1.3 cm in men (n = 62), and 26.6 ± 1.5 cm in women (n = 48). Tube depth significantly correlated with height (r = 0.735, P < 0.001). Distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch correlated with depth of the endotracheal tube (r = 0.363, r = 0.362, and r = 0.546, P < 0.05). The tube depth also correlated with the sum of these distances (r = 0.646, P < 0.001). We devised the following formula for estimating tube depth: 19.856 + 0.267 × sum of the three distances (R 2 = 0.432, P < 0.001). The optimal tube depth for nasotracheally intubated adult patients correlated with height and sum of the distances from nares to tragus, tragus to angle of the mandible, and angle of the mandible to sternal notch. The proposed equation would be a useful guide to determine optimal nasotracheal tube placement.

  2. Tube Bulge Process : Theoretical Analysis and Finite Element Simulations

    International Nuclear Information System (INIS)

    Velasco, Raphael; Boudeau, Nathalie

    2007-01-01

    This paper is focused on the determination of mechanics characteristics for tubular materials, using tube bulge process. A comparative study is made between two different models: theoretical model and finite element analysis. The theoretical model is completely developed, based first on a geometrical analysis of the tube profile during bulging, which is assumed to strain in arc of circles. Strain and stress analysis complete the theoretical model, which allows to evaluate tube thickness and state of stress, at any point of the free bulge region. Free bulging of a 304L stainless steel is simulated using Ls-Dyna 970. To validate FE simulations approach, a comparison between theoretical and finite elements models is led on several parameters such as: thickness variation at the free bulge region pole with bulge height, tube thickness variation with z axial coordinate, and von Mises stress variation with plastic strain. Finally, the influence of geometrical parameters deviations on flow stress curve is observed using analytical model: deviations of the tube outer diameter, its initial thickness and the bulge height measurement are taken into account to obtain a resulting error on plastic strain and von Mises stress

  3. Improvement of hydroforming processes using tailored semi-finished tubes

    Energy Technology Data Exchange (ETDEWEB)

    Goebel, R.; Chatti, S.; Homberg, W.; Kleiner, M.; Shankar, R. [Dortmund Univ. (Germany). Inst. of Forming Technology and Lightweight Construction

    2005-07-01

    The manufacturing of curved tubular workpieces with complex geometry by hydroforming is a well known process. The formability of workpieces is limited by the overall amount of expansion, which always has to start with the smallest perimeter. Especially workpieces with a high ratio between the smallest and widest diameter are critical with regard to their manufacture. To improve the capability the hydroforming process, a new concept using tailored semi-finished tubes with a variable cross-section has been developed. Instead of only expanding a tube with the smallest diameter, the diameter of a tube with middle-sized cross-section is reduced locally by a spinning process so that only the critical regions left have to be expanded. Due to the fact that usually the pre-form has to be bent to assure that it fits into the tool, an additional specialized tube-bending process has been developed to realize the bending of tubes with variable diameter. In this article, the investigation and optimization of this process chain is presented. The capabilities of the process have been improved regarding the behavior of the workpieces in the hydroforming process by manufacturing a complex structural part originating from automotive industry. (orig.)

  4. Storing of Extracts in Polypropylene Microcentrifuge Tubes Yields Contaminant Peak During Ultra-flow Liquid Chromatographic Analysis.

    Science.gov (United States)

    Kshirsagar, Parthraj R; Hegde, Harsha; Pai, Sandeep R

    2016-05-01

    This study was designed to understand the effect of storage in polypropylene microcentrifuge tubes and glass vials during ultra-flow liquid chromatographic (UFLC) analysis. One ml of methanol was placed in polypropylene microcentrifuge tubes (PP material, Autoclavable) and glass vials (Borosilicate) separately for 1, 2, 4, 8, 10, 20, 40, and 80 days intervals stored at -4°C. Contaminant peak was detected in methanol stored in polypropylene microcentrifuge tubes using UFLC analysis. The contaminant peak detected was prominent, sharp detectable at 9.176 ± 0.138 min on a Waters 250-4.6 mm, 4 μ, Nova-Pak C18 column with mobile phase consisting of methanol:water (70:30). It was evident from the study that long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peak. Further, this may mislead in future reporting an unnatural compound by researchers. Long-term storage of biological samples prepared using methanol in polypropylene microcentrifuge tubes produce contaminant peakContamination peak with higher area under the curve (609993) was obtained in ultra-flow liquid chromatographic run for methanol stored in PP microcentrifuge tubesContamination peak was detected at retention time 9.113 min with a lambda max of 220.38 nm and 300 mAU intensity on the given chromatographic conditionsGlass vials serve better option over PP microcentrifuge tubes for storing biological samples. Abbreviations used: UFLC: Ultra Flow Liquid Chromatography; LC: Liquid Chromatography; MS: Mass spectrometry; AUC: Area Under Curve.

  5. Mode Identification of Guided Ultrasonic Wave using Time- Frequency Algorithm

    International Nuclear Information System (INIS)

    Yoon, Byung Sik; Yang, Seung Han; Cho, Yong Sang; Kim, Yong Sik; Lee, Hee Jong

    2007-01-01

    The ultrasonic guided waves are waves whose propagation characteristics depend on structural thickness and shape such as those in plates, tubes, rods, and embedded layers. If the angle of incidence or the frequency of sound is adjusted properly, the reflected and refracted energy within the structure will constructively interfere, thereby launching the guided wave. Because these waves penetrate the entire thickness of the tube and propagate parallel to the surface, a large portion of the material can be examined from a single transducer location. The guided ultrasonic wave has various merits like above. But various kind of modes are propagating through the entire thickness, so we don't know the which mode is received. Most of applications are limited from mode selection and mode identification. So the mode identification is very important process for guided ultrasonic inspection application. In this study, various time-frequency analysis methodologies are developed and compared for mode identification tool of guided ultrasonic signal. For this study, a high power tone-burst ultrasonic system set up for the generation and receive of guided waves. And artificial notches were fabricated on the Aluminum plate for the experiment on the mode identification

  6. Predicting the mechanical behaviour of Kevlar/epoxy and carbon/epoxy filament-wound tubes

    Science.gov (United States)

    Cazeneuve, C.; Joguet, P.; Maile, J. C.; Oytana, C.

    1992-11-01

    The axial, hoop and shear moduli and failure conditions of carbon/epoxy and Kevlar/epoxy filament-wound tubes have been determined through respective applications of internal pressure, tension and torsion. The introduction in the laminated plate theory of a gradual reduction in individual moduli makes it possible to overcome the limitations of the theory and enables accurate predictions to be made of the linear and non-linear stress/strain curves of 90 deg +/- 0/90 deg tubes. The existence of a dominant layer in the failure of the multilayered tubes has been shown experimentally. When associated with a failure criterion applied to the dominant layer, the new model permits the prediction of tube failure. Agreement between calculated and experimental data is better than 5 percent.

  7. Luminous effectiveness of tubular light-guides in tropics

    Energy Technology Data Exchange (ETDEWEB)

    Darula, Stanislav; Kittler, Richard; Kocifaj, Miroslav [ICA, Slovak Academy of Sciences, 9, Dubravska Road, 845 03 Bratislava (Slovakia)

    2010-11-15

    Novel tubular light-guides with a transparent hemispherical cupola placed on an unobstructed flat roof collect all sunlight and skylight available at ground level year round. This advantage is heightened in the dry and sunny tropical regions where the sun rises to very high altitudes and often the hours of sunshine last throughout the whole day. Hollow light-guides with very high inner specular reflectances can transport sunbeams downward into the windowless building core very effectively. Due to the tube's diameter and length and multiple reflections, complex illuminance patterns are produced on the underside of the tube, i.e. on top of the glazed ceiling aperture that illuminates the interior space or its working plane. This paper discusses several daylight conditions in tropical interiors illuminated by tubular light-guides. The recently published HOLIGILM calculation program and the user-friendly tool HOLIGILM 4.2 have facilitated the production of this paper. (author)

  8. The EL-4 reactor. Changing of a pressure tube on a test loop

    International Nuclear Information System (INIS)

    Foulquier, H.; Clara, P.

    1964-01-01

    Right from the beginning of the EL-4 project, the research convected with the overall design of the reactor was guided by the various technical specifications resulting from a justifiable concern about the reliability. The external and internal tubes of each layer situated in the reactor block had in particular to be interchangeable. The research alone into the dismantling of the external tube, i.e in fact the pressure tube, justified a certain number of full-scale tests on a model. The tests carried out under relevant conditions on a non-irradiated structure made it possible to define a complete ranger of of positioning and un-positioning sequences at a distance for such a pressure tube. (authors) [fr

  9. Calculation of reverse flow in inverted U-Tubes of steam generator during natural circulation

    International Nuclear Information System (INIS)

    Yang Ruichang; Liu Jinggong; Liu Ruolei; Qin Shiwei; Huang Yanping

    2010-01-01

    The mechanism of reverse flow in inverted U-tubes of steam generators of pressurized water reactors during natural circulation is analyzed by using the full range characteristic curve of parallel U-tubes. A lumped-distributed model to calculate the reverse flow occurred in inverted U-tubes of real steam generators with a large number of U-tubes during natural circulation is developed. The model has the advantages of quick calculation and high accuracy for the analysis of reverse flow in inverted U-tubes of real steam generators with natural circulation. This model has been used to calculate the normal and reverse flows occurred in inverted U-tubes of a steam generator with natural circulation. The comparison of calculated results indicates a well agreement with that predicted by the model in which normal or reverse flow in each individual U-tube is analyzed, which verifies the reliability of the model developed in this paper. (authors)

  10. Long-range particle manipulation in a micro-capillary tube by using a flexural acoustic wave

    International Nuclear Information System (INIS)

    Kim, Eun-Sun; Kim, Nari; Kim, Young-Ho; Lee, Kwang-Jo; Hwang, In-Kag

    2010-01-01

    We report a one-dimensional manipulation of dry Ag particles in micro-capillary tube by using a flexural acoustic wave propagating along the tube. The capillary tube is used as a mechanical guide for both the particles and the acoustic wave, resulting in an effective interaction between them over a long range of 14 cm in length. Linear transport and local trapping of the particles are demonstrated by the excitation of traveling and standing acoustic waves, respectively. The mechanisms for the particle movements are qualitatively explained by frictional forces between the particles and the inner wall of the capillary tube.

  11. Numerical and experimental research on pentagonal cross-section of the averaging Pitot tube

    Science.gov (United States)

    Zhang, Jili; Li, Wei; Liang, Ruobing; Zhao, Tianyi; Liu, Yacheng; Liu, Mingsheng

    2017-07-01

    Averaging Pitot tubes have been widely used in many fields because of their simple structure and stable performance. This paper introduces a new shape of the cross-section of an averaging Pitot tube. Firstly, the structure of the averaging Pitot tube and the distribution of pressure taps are given. Then, a mathematical model of the airflow around it is formulated. After that, a series of numerical simulations are carried out to optimize the geometry of the tube. The distribution of the streamline and pressures around the tube are given. To test its performance, a test platform was constructed in accordance with the relevant national standards and is described in this paper. Curves are provided, linking the values of flow coefficient with the values of Reynolds number. With a maximum deviation of only  ±3%, the results of the flow coefficient obtained from the numerical simulations were in agreement with those obtained from experimental methods. The proposed tube has a stable flow coefficient and favorable metrological characteristics.

  12. Stress corrosion cracking susceptibility of steam generator tubing on secondary side in restricted flow areas

    International Nuclear Information System (INIS)

    Fulger, M.; Lucan, D.; Radulescu, M.; Velciu, L.

    2003-01-01

    Nuclear steam generator tubes operate in high temperature water and on the secondary side in restricted flow areas many nonvolatile impurities accidentally introduced into circuit tend to concentrate. The concentration process leads to the formation of highly aggressive alkaline or acid solutions in crevices, and these solutions can cause stress corrosion cracking (SCC) on stressed tube materials. Even though alloy 800 has shown to be highly resistant to general corrosion in high temperature water, it has been found that the steam generator tubes may crack during service from the primary and/or secondary side. Stress corrosion cracking is still a serious problem occurring on outside tubes in operating steam generators. The purpose of this study was to evaluate the environmental factors affecting the stress corrosion cracking of steam generators tubing. The main test method was the exposure for 1000 hours into static autoclaves of plastically stressed C-rings of Incoloy 800 in caustic solutions (10% NaOH) and acidic chloride solutions because such environments may sometimes form accidentally in crevices on secondary side of tubes. Because the kinetics of corrosion of metals is indicated by anodic polarization curves, in this study, some stressed specimens were anodically polarized in caustic solutions in electrochemical cell, and other in chloride acidic solutions. The results presented as micrographs, potentiokinetic curves, and electrochemical parameters have been compared to establish the SCC behavior of Incoloy 800 in such concentrated environments. (authors)

  13. Compact TXRF system using doubly curved crystal optics

    International Nuclear Information System (INIS)

    Chen, Z.W.

    2000-01-01

    Doubly curved crystal optics can provide large collection solid angle from a small x-ray source but were difficult to be fabricated in the past. The recent innovative doubly curved crystal optic technology provides accurate bending figure of thin crystal and produces high performance doubly curved crystal optics. The high quality doubly curved crystal can increase the intensity of the primary beam significantly for total reflection x-ray fluorescence application based on a low power x-ray source. In this report, toroidal Si(220) crystals are used to focused Cu Kα and Mo Kα x-rays from low power compact x-ray tubes that have maximum power setting at 50 kV and 1 mA. With a slit aperture to control the convergent angle, a fan Cu Kα1 beam with 15 degree x 0.2 degree convergent angles is obtained for TXRF excitation. Similarly, a fan Mo Kα1 beam with 6 degree x 0.1 degree convergent angles is used for high energy excitation. Si wafer based TXRF samples will be prepared and measured using this technique and the experimental data. (author)

  14. In Vitro Evaluation of Evacuated Blood Collection Tubes as a Closed-Suction Surgical Drain Reservoir.

    Science.gov (United States)

    Heiser, Brian; Okrasinski, E B; Murray, Rebecca; McCord, Kelly

    The initial negative pressures of evacuated blood collection tubes (EBCT) and their in vitro performance as a rigid closed-suction surgical drain (CSSD) reservoir has not been evaluated in the scientific literature despite being described in both human and veterinary texts and journals. The initial negative pressures of EBCT sized 3, 6, 10, and 15 mL were measured and the stability of the system monitored. The pressure-to-volume curve as either air or water was added and maximal filling volumes were measured. Evacuated blood collection tubes beyond the manufacture's expiration date were evaluated for initial negative pressures and maximal filling volumes. Initial negative pressure ranged from -214 mm Hg to -528 mm Hg for EBCT within the manufacturer's expiration date. Different pressure-to-volume curves were found for air versus water. Optimal negative pressures of CSSD are debated in the literature. Drain purpose and type of exudates are factors that should be considered when deciding which EBCT size to implement. Evacuated blood collection tubes have a range of negative pressures and pressure-to-volume curves similar to previously evaluated CSSD rigid reservoirs. Proper drain management and using EBCT within labeled expiration date are important to ensure that expected negative pressures are generated.

  15. Reduction of lateral forces between the railway vehicle and the track in small-radius curves by means of active elements

    Directory of Open Access Journals (Sweden)

    Michálek T.

    2011-12-01

    Full Text Available This paper deals with a possibility of reduction of guiding forces magnitude in small-radius curves by means of active elements. These guiding forces characterize the lateral force interaction between the rail vehicle and the track and influence the wear of wheels and rails in curves. Their magnitudes are assessed in the framework of vehicle authorization process. However, in case of new railway vehicles with axleload of approximately 20t and more it is problematic to meet the condition of maximum value of the quasistatic guiding force which acts on the outer wheel of the 1st wheelset in small-radius curves. One of the possible ways how to reduce these forces is using the system of active yaw dampers. By means of computer simulations of guiding behaviour of a new electric locomotive, comparison of reached values of the quasistatic guiding forces in case of locomotive equipped with active yaw dampers and without them was performed. Influences of magnitude of force generated by the active yaw dampers, friction coefficient in wheel/rail contact and curve radius were analysed in this work, as well.

  16. Verification of Kaplan turbine cam curves realization accuracy at power plant

    Directory of Open Access Journals (Sweden)

    Džepčeski Dane

    2016-01-01

    Full Text Available Sustainability of approximately constant value of Kaplan turbine efficiency, for relatively large net head changes, is a result of turbine runner variable geometry. Dependence of runner blades position change on guide vane opening represents the turbine cam curve. The cam curve realization accuracy is of great importance for the efficient and proper exploitation of turbines and consequently complete units. Due to the reasons mentioned above, special attention has been given to the tests designed for cam curves verification. The goal of this paper is to provide the description of the methodology and the results of the tests performed in the process of Kaplan turbine cam curves verification.

  17. The nature of the essential spectrum in curved quantum waveguides

    International Nuclear Information System (INIS)

    Krejcirik, David; Aldecoa, Rafael Tiedra de

    2004-01-01

    We study the nature of the essential spectrum of the Dirichlet Laplacian in tubes about infinite curves embedded in Euclidean spaces. Under suitable assumptions about the decay of curvatures at infinity, we prove the absence of singular continuous spectrum and state properties of possible embedded eigenvalues. The argument is based on the Mourre conjugate operator method developed for acoustic multistratified domains by Benbernou (1998 J. Math. Anal. Appl. 225 440-60) and Dermenjian et al (1998 Commun. Partial Differ. Equ. 23 141-69). As a technical preliminary, we carry out a spectral analysis for Schroedinger-type operators in straight Dirichlet tubes. We also apply the result to the strips embedded in abstract surfaces

  18. Pleural fluid drainage: Percutaneous catheter drainage versus surgical chest tube drainage

    International Nuclear Information System (INIS)

    Illescas, F.F.; Reinhold, C.; Atri, M.; Bret, P.M.

    1987-01-01

    Over the past 4 years, 55 cases (one transudate, 28 exudates, and 26 empymas) were drained. Surgical chest tubes alone were used in 35 drainages, percutaneous catheters alone in five drainages, and both types in 15 drainages. Percutaneous catheter drainage was successful in 12 of 20 drainages (60%). Surgical tube drainage was successful in 18 of 50 drainages (36%). The success rate for the nonempyema group was 45% with both types of drainage. For the empyema group, the success rate for percutaneous catheter drainage was 66% vs 23% for surgical tube drainage. Seven major complications occurred with surgical tube drainage, but only one major complication occurred with percutaneous catheter drainage. Radiologically guided percutaneous catheter drainage should be the procedure of choice for pleural fluid drainage. It has a higher success rate for empyemas and is associated with less complications

  19. Methods for predicting isochronous stress-strain curves

    International Nuclear Information System (INIS)

    Kiyoshige, Masanori; Shimizu, Shigeki; Satoh, Keisuke.

    1976-01-01

    Isochronous stress-strain curves show the relation between stress and total strain at a certain temperature with time as a parameter, and they are drawn up from the creep test results at various stress levels at a definite temperature. The concept regarding the isochronous stress-strain curves was proposed by McVetty in 1930s, and has been used for the design of aero-engines. Recently the high temperature characteristics of materials are shown as the isochronous stress-strain curves in the design guide for the nuclear energy equipments and structures used in high temperature creep region. It is prescribed that these curves are used as the criteria for determining design stress intensity or the data for analyzing the superposed effects of creep and fatigue. In case of the isochronous stress-strain curves used for the design of nuclear energy equipments with very long service life, it is impractical to determine the curves directly from the results of long time creep test, accordingly the method of predicting long time stress-strain curves from short time creep test results must be established. The method proposed by the authors, for which the creep constitution equations taking the first and second creep stages into account are used, and the method using Larson-Miller parameter were studied, and it was found that both methods were reliable for the prediction. (Kako, I.)

  20. Preliminary research on eddy current bobbin quantitative test for heat exchange tube in nuclear power plant

    Science.gov (United States)

    Qi, Pan; Shao, Wenbin; Liao, Shusheng

    2016-02-01

    For quantitative defects detection research on heat transfer tube in nuclear power plants (NPP), two parts of work are carried out based on the crack as the main research objects. (1) Production optimization of calibration tube. Firstly, ASME, RSEM and homemade crack calibration tubes are applied to quantitatively analyze the defects depth on other designed crack test tubes, and then the judgment with quantitative results under crack calibration tube with more accuracy is given. Base on that, weight analysis of influence factors for crack depth quantitative test such as crack orientation, length, volume and so on can be undertaken, which will optimize manufacture technology of calibration tubes. (2) Quantitative optimization of crack depth. Neural network model with multi-calibration curve adopted to optimize natural crack test depth generated in in-service tubes shows preliminary ability to improve quantitative accuracy.

  1. Current microbiology of percutaneous endoscopic gastrostomy tube (PEG tube) insertion site infections in patients with cancer.

    Science.gov (United States)

    Rolston, Kenneth V I; Mihu, Coralia; Tarrand, Jeffrey J

    2011-08-01

    Percutaneous endoscopic gastrostomy (PEG) is frequently used to provide enteral access in cancer patients who are unable to swallow. Infection is an important complication in this setting. Current microbiological data are needed to guide infection prevention and treatment strategies. The microbiological records of our institution (a 550-bed comprehensive cancer center) were retrospectively reviewed over an 8-month study period in order to identify patients who developed PEG tube insertion site infections, and review their microbiological details and susceptibility/resistance data. Fifty-eight episodes of PEG tube insertion site infections were identified. Of these, 31 (53%) were monomicrobial, and the rest were polymicrobial. The most common organisms isolated were Candida species, Staphylococcus aureus, and Pseudomonas aeruginosa. All infections were local (cellulitis, complicated skin, and skin structure infections including abdominal wall abscess) with no cases of concomitant bacteremia being documented. Most of the organisms isolated were susceptible to commonly used antimicrobial agents, although some quinolone-resistant and some multidrug-resistant organisms were isolated. This retrospective study provides descriptive data regarding PEG tube insertion site infections. These data have helped us update institutional guidelines for infection prevention and treatment as part of our focus on antimicrobial stewardship.

  2. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film.

    Science.gov (United States)

    De Melo, Daniela Pita; Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-04-01

    To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494-0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images.

  3. Effect of Different Tube Potential Settings on Caries Detection using PSP Plate and Conventional Film

    Science.gov (United States)

    Cruz, Adriana Dibo; Melo, Saulo Leonardo Sousa; De Farias, Julyanna Filgueiras GonçAlves; Haiter-Neto, Francisco; De Almeida, Solange Maria

    2015-01-01

    Purpose To compare intraoral Phosphor Stimulable Plate digital system and intraoral film using different tube settings on incipient proximal caries detection. Materials and Methods Five blocks, with five teeth each, were radiographically examined using phosphor plates and F-speed films. The images were acquired in 07 different tube potentials from 50-80 kV. The films were digitized. Three oral radiologists scored the images for the presence of caries using a 5-point rating scale. The areas under ROC curve were calculated. The influence of tube kilovoltage was verified by ANOVA and pair wise comparisons performed using Tukey test. Results Mean ROC curve areas varied from 0.446-0.628 for digital images and 0.494–0.559 for conventional images. The tube setting of 70 kV presented the best result both for digital and conventional images. Considering the image type separately, 70 kV scored highest followed by 75 and 65 kV for digital images (p=0.084). For conventional image modality, even though 70 kV presented the best result, it did not differ significantly from 80 kV, not differing from 60 and 55 kV, which did not differ from 75, 65 and 50 kV (p=0.53). Conclusion Phosphor plate digital images seem to be more susceptible to tube setting potential variations then digitized film images. PMID:26023645

  4. Usefulness of normal saline for sealing the needle track after CT-guided lung biopsy

    International Nuclear Information System (INIS)

    Li, Y.; Du, Y.; Luo, T.Y.; Yang, H.F.; Yu, J.H.; Xu, X.X.; Zheng, H.J.; Li, B.

    2015-01-01

    Aim: To determine whether the use of normal saline for sealing the needle track can reduce the incidence of pneumothorax and chest tube placement after computed tomography (CT)-guided lung biopsy. Materials and methods: A prospective, randomised, controlled trial enrolling 322 patients was conducted. All patients were randomly assigned to one of two groups: those in whom the needle track was not sealed with normal saline (n=161, Group A) and those who did receive normal saline (n=161, Group B). CT-guided biopsy was performed with coaxial technique. Normal saline, which ranged from 1–3 ml, was injected while the trocar needle was being withdrawn. Patient characteristics, lesion, and procedure variables were analysed as potential risk variables for occurrence of pneumothorax and chest tube placement. Results: The incidence of pneumothorax was 26.1% in Group A and 6.2% in Group B (p<0.001). Nine patients in Group A and one patient in Group B required chest tube placement (p=0.010). Using multiple logistic regression analysis, smaller lesion size, greater needle–pleural angle, longer lesion–pleural distance, presence of emphysema, and no sealing the needle track with normal saline were significantly associated with an increased risk of pneumothorax, and that the latter three factors were also associated with an increased risk of pneumothorax requiring chest tube placement. Conlusion: Normal saline for sealing the needle track significantly reduces the incidence of pneumothorax and prevents subsequent chest tube placement after CT-guided lung biopsy. - Highlights: • Normal saline is an effective sealant for use in lung biopsy. • This technique reduced the incidence of pneumothorax and chest tube placement. • This technique should be recommended for CT-guided lung biopsy.

  5. The study on nondestructive evaluation for a tubular structure by the lamb-type guided wave wedge

    International Nuclear Information System (INIS)

    Cho, Yun Ho; Park, Jung Chul

    1998-01-01

    The study on the cylindrical guided wave was carried out to investigate its feasibility for nondestructive evaluation of tubular structures such as heat exchanger tubings of power industries and various pipings of chemical plants. The concept of wedge design and incident angle selection to optimize guided wave generation is presented based on the dispersion theory and the snell's law for the cylindrical guided wave. The brass tubes with artificial defects in the circumferential or axial direction were used for detect defection experiments. It was found that guided wave sensitivity for detecting an axial defect can be remarkably improved by using non-axisymmetrically launched guided waves. Through this study, it is expected that the guided wave can be successfully applied to tubular structure inspections as an more advanced and efficient NDE technique than a conventional point-by-point technique.

  6. X-ray tube monitor apparatus

    International Nuclear Information System (INIS)

    Holland, W.P.; Pellergrino, A.

    1981-01-01

    An x-ray tube with a rotating anode target is provided with a detector of x-rays located outside a port of a housing of the tube and positioned at or near a tangent line to the radiating surface for observing variations in the radiation intensity due to rotation of the target, the variations being pronounced due to the heel effect of the radiation pattern. The x-ray detector can employ a scintillation material and be coupled by a light guide to a photodetector which is removed from the path of the radiation and detects scintillations of the x-ray detector. Alternatively, the photodetector and light pipe may be replaced by a detector of germanium, silicon or an ion chamber which converts x-ray photons directly to an electric current. An electronic unit determines the speed of rotation from the electric signal and can also, by fourier transform and signature analysis techniques, monitor the state of the radiating surface. (author)

  7. A new method to determine in situ the transmission of a neutron-guide system at a reactor source

    CERN Document Server

    Haan, V O D; Gommers, R M; Labohm, F; Well, A A V; De Leege, P F A; Schebetov, A; Pusenkov, V

    2002-01-01

    In this paper, a description of a new method to determine the transmission of neutron guides after they are installed in a beam-tube at a reactor source is given. The method is based on activation measurements of gold foils at the entrance of the beam-tube and at the exit of the neutron guides compared to Monte-Carlo calculations. In this method, a quality factor is defined as the ratio between the actual transmission and the theoretical maximum attainable transmission. This method is used to determine the quality of an optimised neutron-guide system developed for beam-tube R2 of the HOR. The HOR is a pool-type nuclear research reactor at the Interfaculty Reactor Institute of the Delft University of Technology. It is shown that the quality factors of the newly installed neutron guides are between 0.49 and 0.63.

  8. A new method to determine in situ the transmission of a neutron-guide system at a reactor source

    International Nuclear Information System (INIS)

    Haan, V.O. de; Gibcus, H.P.M.; Gommers, R.M.; Labohm, F.; Well, A.A. van; Leege, P.F.A. de; Schebetov, A.; Pusenkov, V.

    2002-01-01

    In this paper, a description of a new method to determine the transmission of neutron guides after they are installed in a beam-tube at a reactor source is given. The method is based on activation measurements of gold foils at the entrance of the beam-tube and at the exit of the neutron guides compared to Monte-Carlo calculations. In this method, a quality factor is defined as the ratio between the actual transmission and the theoretical maximum attainable transmission. This method is used to determine the quality of an optimised neutron-guide system developed for beam-tube R2 of the HOR. The HOR is a pool-type nuclear research reactor at the Interfaculty Reactor Institute of the Delft University of Technology. It is shown that the quality factors of the newly installed neutron guides are between 0.49 and 0.63

  9. Monte Carlo modelling for neutron guide losses

    International Nuclear Information System (INIS)

    Cser, L.; Rosta, L.; Toeroek, Gy.

    1989-09-01

    In modern research reactors, neutron guides are commonly used for beam conducting. The neutron guide is a well polished or equivalently smooth glass tube covered inside by sputtered or evaporated film of natural Ni or 58 Ni isotope where the neutrons are totally reflected. A Monte Carlo calculation was carried out to establish the real efficiency and the spectral as well as spatial distribution of the neutron beam at the end of a glass mirror guide. The losses caused by mechanical inaccuracy and mirror quality were considered and the effects due to the geometrical arrangement were analyzed. (author) 2 refs.; 2 figs

  10. PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyeon Ji; Ji, Ho Seong; Kim, Kyung Chun [Pusan Nat’l Univ., Busan (Korea, Republic of)

    2016-08-15

    Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent 10° from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

  11. PIV Measurement of Pulsatile Flows in 3D Curved Tubes Using Refractive Index Matching Method

    International Nuclear Information System (INIS)

    Hong, Hyeon Ji; Ji, Ho Seong; Kim, Kyung Chun

    2016-01-01

    Three-dimensional models of stenosis blood vessels were prepared using a 3D printer. The models included a straight pipe with axisymmetric stenosis and a pipe that was bent 10° from the center of stenosis. A refractive index matching method was utilized to measure accurate velocity fields inside the 3D tubes. Three different pulsatile flows were generated and controlled by changing the rotational speed frequency of the peristaltic pump. Unsteady velocity fields were measured by a time-resolved particle image velocimetry method. Periodic shedding of vortices occurred and moves depended on the maximum velocity region. The sizes and the positions of the vortices and symmetry are influenced by mean Reynolds number and tube geometry. In the case of the bent pipe, a recirculation zone observed at the post-stenosis could explain the possibility of blood clot formation and blood clot adhesion in view of hemodynamics.

  12. Development of guide thimble stress peaking factor calculation methodology

    International Nuclear Information System (INIS)

    Lee, Seong Ki; Jeon, Sang Youn; Kim, Jae Ik; Jeon, Kyeong Lak; Kim, Kyu Tae

    2004-01-01

    The Nuclear Fuel Assembly for light water reactor which provides for 236 fuel rods consists of guide tubes, spacer grids, top/bottom nozzles. The guide tubes form the main structural components in conjunction with the grids, act as the main load carrying members of fuel assembly and serve as a support structure and a guide path for the control element, neutron sources and incore instruments after they are secured to upper and lower end areas. Top/bottom nozzles make the end parts of fuel assembly. And the spacer girds maintain the fuel rod array by providing positive lateral restraint to the fuel rod to the fuel rod but only frictional restraint to axial fuel rod motion. When the fuel assembly is in reactor, the tensional and compressional forces are applied to guide thimble through the top nozzle. The stresses vary with the location of guide thimble on the top nozzle plate since the different flow plate thickness between center and outer areas causes a different flexibility. The relative stress shall be considered during designing this kind of structure. And it is useful to know a coefficient to represent this relative stress difference and this value is called stress peaking factor

  13. Framatome experience and programs in relation to guide tube support pin cracking

    International Nuclear Information System (INIS)

    Benhamou, C.; Poitrenaud, P.

    1989-01-01

    Guide tube support pins installed in the upper internals of pressurized water reactors (PWR) have failed by stress corrosion cracking (SCC). Typical pin crack locations are in the first thread area, shank-to-shoulder transition, and at the end of the leaves. The support pins were made of Inconel X-750 with a solution treatment between 885 degree C (1625 degree F) and 1150 degree C (2100 degree F), followed by a single or double aging, depending on the material supplier. EDF and Framatome initiated an extensive program to address the concern for the potential of support pin cracking in 21 operating units. Short-term actions identified the cause of cracking as a combination of inherent high design stress and a material susceptible to stress corrosion cracking. Long-range objectives are to determine the relation between metallurgy and SCC resistance and to decrease the operating stress. Second-generation design improvements to increase SCC resistance included a revised heat treatment of solution annealing at 1093 degree C (2000 degree F) followed by aging at 704 degree C (1300 degree F), and use of a parabolic radius in the shank/shoulder area, and decreasing the installation torque. Third generation changes included an improved torquing procedure, polishing of crack-sensitive areas, and tighter dimensional control. Fourth-generation pin modifications required the use of Inconel X-750 water quenched from the solution-annealing temperature to improve resistance to SCC with thread rolling after aging. Stress corrosion cracking tests of Inconel X-750, 718, and A286 in a PWR environment were performed. Smooth tensile data on Inconel X-750 with the second-generation heat treatment allowed a life prediction of 80,000 hours or 11 years for a stress level about yield strength. The effect of grain size, grain boundary phases, and precipitate morphology on resistance to stress corrosion cracking were also evaluated

  14. A simulation of the optical attenuation of TPB coated light-guide detectors

    International Nuclear Information System (INIS)

    Jones, B J P

    2013-01-01

    This note is provided as a supplementary section to accompany the paper [1] which has been included in these proceedings. It describes some simple simulations which were performed in order to understand the attenuation behaviors of acrylic light-guides operated in air and argon, which were characterized in [2]. Whilst these simulations are only at the level of sophistication of a toy model, they illustrate interesting non-exponential light attenuation effects and the differences between operating light-guide based detectors in argon and air environments. We investigate the effects of surface absorption, surface roughness and wavelength dependence, and use a model tuned on the light-guide attenuation curve measured in air to make a prediction of the light-guide attenuation curve in argon. This curve is compared with data from a liquid argon test stand, and an improvement over a simple exponential model is observed

  15. Settling time of dental x-ray tube head after positioning

    International Nuclear Information System (INIS)

    Yun, Suk Ja; Kang, Byung Cheol; Wang, Se Myung; Koh, Chang Sung

    2002-01-01

    The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X-axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 11 seconds for the mobile-types. Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after xray tube head positioning for better radiographic resolution.

  16. Settling time of dental x-ray tube head after positioning

    Energy Technology Data Exchange (ETDEWEB)

    Yun, Suk Ja; Kang, Byung Cheol [Department of Oral and Maxillofacial Radiology, Chonnam National University, Gwangju (Korea, Republic of); Wang, Se Myung; Koh, Chang Sung [Department of Mechatronics, Kwangju Institute of Science and Technology, Gwangju (Korea, Republic of)

    2002-09-15

    The aim of this study was to introduce a method of obtaining the oscillation graphs of the dental x-ray tube heads relative to time using an accelerometer. An Accelerometer, Piezotron type 8704B25 (Kistler Instrument Co., Amherst, NY, USA) was utilized to measure the horizontal oscillation of the x-ray tube head immediately after positioning the tube head for an intraoral radiograph. The signal from the sensor was transferred to a dynamic signal analyzer, which displayed the magnitude of the acceleration on the Y-axis and time lapse on the X-axis. The horizontal oscillation of the tube head was measured relative to time, and the settling time was also determined on the basis of the acceleration graphs for 6 wall type, 5 floor-fixed type, and 4 mobile type dental x-ray machines. The oscillation graphs showed that tube head movement decreased rapidly over time. The settling time varied with x-ray machine types. Wall-type x-ray machines had a settling time of up to 6 seconds, 5 seconds for fixed floor-types, and 11 seconds for the mobile-types. Using an accelerometer, we obtained the oscillation graphs of the dental x-ray tube head relative to time. The oscillation graph with time can guide the operator to decide upon the optimum exposure moment after xray tube head positioning for better radiographic resolution.

  17. Machining of the nuclear tube sheet with small hole diameter

    International Nuclear Information System (INIS)

    Lin Lifeng

    2010-01-01

    Regarding the tube sheet for the heat exchanger of Qinshan Phase II extension project, its material is 00Cr19Ni10 forgings, the tube sheet thickness is 125 mm, requiring 178-φ10.35 0 +0.05 hole, the tube array shall take the shape of equilateral triangle, the center distance is 15 mm, and the tube hole roughness is Ra 3.2. The guide sleeve shall be adopted for positioning prior to machining of the high precision small hole of the thick tube sheet, and the gun drill and BTA drill shall be adopted for testing, finally BTA drilling with internal chip removal shall be adopted, this method shall overcome the disadvantage factor of BTA drilling and shall be the new approach for drilling. The diameter of BTA drill is φ10.34 mm. The machined hole diameter shall be φ10.375-φ10.355 mm. The ellipticity of the tube hole shall be less than 0.01 mm, the pipe bridge dimension shall be 4.6 mm, conforming to the requirement of the drawing. The paper presents the precautions during machining so as to provide the reference for the similar pipe hole machining in the future. (author)

  18. Effects of draft tube on the hydraulic performance of a Francis turbine

    International Nuclear Information System (INIS)

    Jeon, J H; Byeon, S S; Kim, Y J

    2013-01-01

    The draft tube is an important component of a Francis turbine which influences the hydraulic performance. It is located just under the runner and allowed to decelerate the flow velocity exiting the runner, thereby converting the excess of kinetic energy into static pressure. In this study, we have numerically investigated the hydraulic performance of a Francis turbine on the 15MW hydropower generation with various design parameters (three types of draft tube, thickness of guide vane) through a three-dimensional numerical method with the SST turbulent model. The vortex rope characteristics of the draft tube were confirmed. The results of the vortex flow fields and flow characteristics were graphically depicted with different design parameters and operating conditions

  19. Tensile and fracture toughness characteristics of Zr-2.5Nb pressure tube

    International Nuclear Information System (INIS)

    Jung, H. C.; Kim, Y. S.; Ahn, S. B.; Kim, S. S.; Im, K. S.

    2004-01-01

    The object of this study is to evaluate the characteristics of tensile and fracture toughness of Zr-2.5Nb pressure tube. The transverse tensile tests were performed at various temperatures and the fracture toughness tests were carried out at room temperature using the CCT (curved compact tension) specimen. These specimens were directly machined from the pressure tube retaining original curvatures. Also, the fracture toughness of two sets of Zr-2.5Nb manufactured at different time was compared. The chemical analysis and the Vicker's hardness tests were performed at two sets of Zr-2.5Nb pressure tube. The Vicker's hardness value of SET-2 containing more oxygen and carbon relatively was higher about 11 than that of SET-1

  20. Numerical and experimental research on pentagonal cross-section of the averaging Pitot tube

    International Nuclear Information System (INIS)

    Zhang, Jili; Li, Wei; Liang, Ruobing; Zhao, Tianyi; Liu, Yacheng; Liu, Mingsheng

    2017-01-01

    Averaging Pitot tubes have been widely used in many fields because of their simple structure and stable performance. This paper introduces a new shape of the cross-section of an averaging Pitot tube. Firstly, the structure of the averaging Pitot tube and the distribution of pressure taps are given. Then, a mathematical model of the airflow around it is formulated. After that, a series of numerical simulations are carried out to optimize the geometry of the tube. The distribution of the streamline and pressures around the tube are given. To test its performance, a test platform was constructed in accordance with the relevant national standards and is described in this paper. Curves are provided, linking the values of flow coefficient with the values of Reynolds number. With a maximum deviation of only  ±3%, the results of the flow coefficient obtained from the numerical simulations were in agreement with those obtained from experimental methods. The proposed tube has a stable flow coefficient and favorable metrological characteristics. (paper)

  1. Collapse of thin wall tubes small initial ovality; Colapso de tubos de pared delgada con pequena ovalidad inicial

    Energy Technology Data Exchange (ETDEWEB)

    Moreno, A

    1977-07-01

    In this work a simple model of creep collapse of tubes based on the bending theory of curved beams, is developed. The model is compared with more complex models. The main result of this work is the definition of a new model of creep collapse of tubes with a minimum of limitative hypothesis. (Author) 6 refs.

  2. Electro-optical design of a long slit streak tube

    Science.gov (United States)

    Tian, Liping; Tian, Jinshou; Wen, Wenlong; Chen, Ping; Wang, Xing; Hui, Dandan; Wang, Junfeng

    2017-11-01

    A small size and long slit streak tube with high spatial resolution was designed and optimized. Curved photocathode and screen were adopted to increase the photocathode working area and spatial resolution. High physical temporal resolution obtained by using a slit accelerating electrode. Deflection sensitivity of the streak tube was improved by adopting two-folded deflection plates. The simulations indicate that the photocathode effective working area can reach 30mm × 5mm. The static spatial resolution is higher than 40lp/mm and 12lp/mm along scanning and slit directions respectively while the physical temporal resolution is higher than 60ps. The magnification is 0.75 and 0.77 in scanning and slit directions. And also, the deflection sensitivity is as high as 37mm/kV. The external dimension of the streak tube are only ∅74mm×231mm. Thus, it can be applied to laser imaging radar system for large field of view and high range precision detection.

  3. Efficacy of ultrasound-guided thoracentesis catheter drainage for pleural effusion

    Science.gov (United States)

    Cao, Weitian; Wang, Yi; Zhou, Ningming; Xu, Bing

    2016-01-01

    The factors influencing the efficacy of ultrasound-guided thoracentesis catheter drainage were investigated in the present study. A retrospective analysis of clinical data from 435 patients who presented with a pleural effusion was performed. Patients were divided into a control group and an intervention group. Thirty-seven patients in the control group were given standard care using pleural puncture to draw the excess fluid. The 398 patients in the intervention group were treated using ultrasound-guided thoracentesis catheter drainage. The rate of successful drainage of a pleural effusion was significantly higher (Ppleural effusion. The efficacy of the procedure is related to the separation of pleural effusion, drainage tube type and tube diameter. PMID:28105155

  4. Atom Skimmers and Atom Lasers Utilizing Them

    Science.gov (United States)

    Hulet, Randall; Tollett, Jeff; Franke, Kurt; Moss, Steve; Sackett, Charles; Gerton, Jordan; Ghaffari, Bita; McAlexander, W.; Strecker, K.; Homan, D.

    2005-01-01

    Atom skimmers are devices that act as low-pass velocity filters for atoms in thermal atomic beams. An atom skimmer operating in conjunction with a suitable thermal atomic-beam source (e.g., an oven in which cesium is heated) can serve as a source of slow atoms for a magneto-optical trap or other apparatus in an atomic-physics experiment. Phenomena that are studied in such apparatuses include Bose-Einstein condensation of atomic gases, spectra of trapped atoms, and collisions of slowly moving atoms. An atom skimmer includes a curved, low-thermal-conduction tube that leads from the outlet of a thermal atomic-beam source to the inlet of a magneto-optical trap or other device in which the selected low-velocity atoms are to be used. Permanent rare-earth magnets are placed around the tube in a yoke of high-magnetic-permeability material to establish a quadrupole or octupole magnetic field leading from the source to the trap. The atoms are attracted to the locus of minimum magnetic-field intensity in the middle of the tube, and the gradient of the magnetic field provides centripetal force that guides the atoms around the curve along the axis of the tube. The threshold velocity for guiding is dictated by the gradient of the magnetic field and the radius of curvature of the tube. Atoms moving at lesser velocities are successfully guided; faster atoms strike the tube wall and are lost from the beam.

  5. Fuel buyers guide: company data

    International Nuclear Information System (INIS)

    Anon.

    1991-01-01

    Four major listings relating to nuclear fuel services are provided. 1. A fuel buyer's guide listing companies under alphabetical order of country and giving addresses and an indication of the services offered. 2. A fuel buyers guide classifying companies in alphabetical order of the services offered. 3. A fuel and front end facility listing subdivided into companies involved in: uranium ore processing; uranium refining and conversion; enrichment; fuel fabrication; heavy water production; zirconium metal production; and zirconium tube production. 4. A fuel and front end facilities listing giving operators' addresses under alphabetical order of country. (UK)

  6. EPRI's pumped storage planning and evaluation guide

    International Nuclear Information System (INIS)

    Chen, H.H.

    1991-01-01

    EPRI's Hydropower Pumped Storage Planning and Evaluation Guide was published in 1990. The Guide provides step-by-step procedures to: evaluate pumped-storage operation in a utility system, establish site development concept, estimate capital cost, and conduct economic analysis. The Guide provides a floppy diskette containing a production costing model simulating the chronologic operation of pumped storage in a generating system. It provides a series of estimating curves for the preparation of capital cost estimates. The paper presents how the Guide was organized and prepared, and highlights its contents

  7. Numerical Simulation of Liquid Nitrogen Chilldown of a Vertical Tube

    Science.gov (United States)

    Darr, Samuel; Hu, Hong; Schaeffer, Reid; Chung, Jacob; Hartwig, Jason; Majumdar, Alok

    2015-01-01

    This paper presents the results of a one-dimensional numerical simulation of the transient chilldown of a vertical stainless steel tube with liquid nitrogen. The direction of flow is downward (with gravity) through the tube. Heat transfer correlations for film, transition, and nucleate boiling, as well as critical heat flux, rewetting temperature, and the temperature at the onset of nucleate boiling were used to model the convection to the tube wall. Chilldown curves from the simulations were compared with data from 55 recent liquid nitrogen chilldown experiments. With these new correlations the simulation is able to predict the time to rewetting temperature and time to onset of nucleate boiling to within 25% for mass fluxes ranging from 61.2 to 1150 kg/(sq m s), inlet pressures from 175 to 817 kPa, and subcooled inlet temperatures from 0 to 14 K below the saturation temperature.

  8. The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography

    International Nuclear Information System (INIS)

    Santos, Joana; Paulo, Graciano; Foley, Shane; Rainford, Louise; McEntee, Mark F.

    2015-01-01

    The volume of CT examinations has increased with resultant increases in collective dose values over the last decade. To analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations. Head CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed. Pediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693). Pediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings. (orig.)

  9. The impact of pediatric-specific dose modulation curves on radiation dose and image quality in head computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Santos, Joana; Paulo, Graciano [Instituto Politecnico de Coimbra, ESTESC, DMIR, Coimbra (Portugal); Foley, Shane; Rainford, Louise [University College Dublin, School of Medicine and Medical Science, Health Science Centre, Dublin 4 (Ireland); McEntee, Mark F. [The University of Sydney, Faculty of Health Sciences, Cumberland Campus, Sydney (Australia)

    2015-11-15

    The volume of CT examinations has increased with resultant increases in collective dose values over the last decade. To analyze the impact of the tube current and voltage modulation for dose values and image quality of pediatric head CT examinations. Head CT examinations were performed on anthropomorphic phantoms and four pediatric age categories before and after the introduction of dedicated pediatric curves for tube voltage and current modulation. Local diagnostic reference levels were calculated. Visual grading characteristic image quality evaluation was performed by four pediatric neuroradiologists and image noise comparisons were performed. Pediatric-specific modulation curves demonstrated a 49% decrease in mean radiation dose for phantom examinations. The local diagnostic reference levels (CTDIvol) for clinical examinations decreased by 52%, 41%, 46% and 40% for newborn, 5-, 10- and 15-year-old patients, respectively. Visual grading characteristic image quality was maintained for the majority of age categorizations (area under the curve = 0.5) and image noise measurements did not change (P = 0.693). Pediatric-specific dose modulation curves resulted in an overall mean dose reduction of 45% with no significant differences in subjective or objective image quality findings. (orig.)

  10. Experimental Investigation of Average Heat-Transfer and Friction Coefficients for Air Flowing in Circular Tubes Having Square-Thread-Type Roughness

    Science.gov (United States)

    Sams, E. W.

    1952-01-01

    An investigation of forced-convection heat transfer and associated pressure drops was conducted with air flowing through electrically heated Inconel tubes having various degrees of square-thread-type roughness, an inside diameter of 1/2 inch, and a length of 24 inches. were obtained for tubes having conventional roughness ratios (height of thread/radius of tube) of 0 (smooth tube), 0.016, 0.025, and 0.037 over ranges of bulk Reynolds numbers up to 350,000, average inside-tube-wall temperatures up to 1950deg R, and heat-flux densities up to 115,000 Btu per hour per square foot. Data The experimental data showed that both heat transfer and friction increased with increase in surface roughness, becoming more pronounced with increase in Reynolds number; for a given roughness, both heat transfer and friction were also influenced by the tube wall-to-bulk temperature ratio. Good correlation of the heat-transfer data for all the tubes investigated was obtained by use of a modification of the conventional Nusselt correlation parameters wherein the mass velocity in the Reynolds number was replaced by the product of air density evaluated at the average film temperature and the so-called friction velocity; in addition, the physical properties of air were evaluated at the average film temperature. The isothermal friction data for the rough tubes, when plotted in the conventional manner, resulted in curves similar to those obtained by other investigators; that is, the curve for a given roughness breaks away from the Blasius line (representing turbulent flow in smooth tubes) at some value of Reynolds number, which decreases with increase in surface roughness, and then becomes a horizontal line (friction coefficient independent of Reynolds number). A comparison of the friction data for the rough tubes used herein indicated that the conventional roughness ratio is not an adequate measure of relative roughness for tubes having a square-thread-type element. The present data, as well

  11. Influence of upstream disturbance on the draft-tube flow of Francis turbine under part-load conditions

    Science.gov (United States)

    Chen, Ting; Zheng, Xianghao; Zhang, Yu-ning; Li, Shengcai

    2018-02-01

    Owing to the part-load operations for the enhancement of grid flexibility, the Francis turbine often suffers from severe low-frequency and large-amplitude hydraulic instability, which is mostly pertinent to the highly unsteady swirling vortex rope in the draft tube. The influence of disturbances in the upstream (e.g., large-scale vortex structures in the spiral casing) on the draft-tube vortex flow is not well understood yet. In the present paper, the influence of the upstream disturbances on the vortical flow in the draft tube is studied based on the vortex identification method and the analysis of several important parameters (e.g., the swirl number and the velocity profile). For a small guide vane opening (representing the part-load condition), the vortices triggered in the spiral casing propagate downstream and significantly affect the swirling vortex-rope precession in the draft tube, leading to the changes of the intensity and the processional frequency of the swirling vortex rope. When the guide vane opening approaches the optimum one (representing the full-load condition), the upstream disturbance becomes weaker and thus its influences on the downstream flow are very limited.

  12. Guide design study for the high-resolution backscattering spectrometer FIRES

    Energy Technology Data Exchange (ETDEWEB)

    Pelley, C; Kargl, F; Sakai, V Garcia; Telling, M T F; Fernandez-Alonso, F; Demmel, F, E-mail: franz.demmel@stfc.ac.uk

    2010-11-01

    Different options are considered to transport cold neutrons along 90 m for the proposed new spectrometer FIRES at the ISIS facility. Monte Carlo simulations using the McStas programme package are used to assess the performance of various guide designs from the biological shield to the sample position. By employing a curved geometry, to avoid the direct line of sight, a hybrid design which combines a curved ballistic guide and an elliptic focusing section appears to be the best solution.

  13. The effective Hamiltonian in curved quantum waveguides under mild regularity assumptions

    Czech Academy of Sciences Publication Activity Database

    Krejčiřík, David; Šediváková, Helena

    2012-01-01

    Roč. 24, č. 7 (2012), 1250018/1-1250018/39 ISSN 0129-055X R&D Projects: GA MŠk LC06002; GA ČR GAP203/11/0701 Institutional support: RVO:61389005 Keywords : quantum waveguides * thin-width limit * effective Hamiltonian * twisting versus bending * norm-resolvent convergence * Dirichlet Laplacian * curved tubes * relatively parallel frame * Steklov approximation Subject RIV: BE - Theoretical Physics Impact factor: 1.092, year: 2012

  14. Numerical investigation of heat transfer characteristic of fixed planar elastic tube bundles

    International Nuclear Information System (INIS)

    Duan, Derong; Ge, Peiqi; Bi, Wenbo

    2015-01-01

    Highlights: • Both tube-side and shell-side of planar elastic tube bundles were investigated. • Heat transfer and fluid flow were studied from the local analysis perspective. • Secondary flow varies depending on the fluid flow state and the geometry of tube. • Curvature plays a role on the external flow field. • The heat transfer of the two intermediate tube bundles is augmented. - Abstract: Planar elastic tube bundles are a novel approach to enhance heat transfer by using flow-induced vibration. This paper studied the heat transfer characteristic and fluid flow in both tube-side and shell-side using numerical simulation. Two temperature difference formulas were used to calculate convective heat transfer coefficient and the results were verified by theoretical analysis and experimental correlations. The effect of Reynolds number on overall convective heat transfer coefficient and pressure drop in tube-side and shell-side were studied. The comparison of the secondary flow in planar elastic tube bundles and conical spiral tube bundles were conducted. The external flow field and local convective heat transfer around the periphery of fixed planar elastic tube bundles subjected to the cross fluid flow were also analyzed. The results show that the energy consumption efficiency should be taken into account in the forced heat transfer process conducted by adjusting the fluid flow. The secondary flow varies depending on the fluid flow state and the geometry of tube. Hence, it is deduced that the heat transfer enhancement is obtained because the thermal boundary layer in the deformed planar elastic tube bundles caused by flow-induced vibration is damaged by the disordered secondary flow. In addition, the convective heat transfer capability of outside the two intermediate tube bundles is enhanced because of the effect of irregular and complex fluid flow affected by the role of curved tubes on both sides

  15. Antimicrobial Activity of Single-Walled Carbon Nano tubes Suspended in Different Surfactants

    International Nuclear Information System (INIS)

    Dong, L.; Alex Henderson, A.; Field, Ch.

    2012-01-01

    We investigated the antibacterial activity of single-walled carbon nano tubes (SWCNTs) dispersed in surfactant solutions of sodium cholate, sodium dodecylbenzene sulfonate, and sodium dodecyl sulfate. Among the three surfactants, sodium cholate demonstrated the weakest antibacterial activity against Salmonella enterica, Escherichia coli, and Enterococcus faecium and thereby was used to disperse bundled SWCNTs in order to study nano tube antibiotic activity. SWCNTs exhibited antibacterial characteristics for both S. enterica and E. coli. With the increase of nano tube concentrations from 0.3 mg/mL to 1.5 mg/mL, the growth curves had plateaus at lower absorbance values whereas the absorbance value was not obviously affected by the incubation ranging from 5?min to 2 h. Our findings indicate that carbon nano tubes could become an effective alternative to antibiotics in dealing with drug-resistant and multidrug-resistant bacterial strains because of the physical mode of bactericidal action that SWCNTs display

  16. Development of automated lance systems for removing deposited sludge around heat transfer tubes with a trianglar pattern in a steam

    International Nuclear Information System (INIS)

    Hwang, K. S.; Sung, H. J.; Jeong, W. T.; Hong, S. Y.; Park, Y. S.

    2003-01-01

    Automated lance systems have been developed to remove sludge deposits filed up around the heat transfer tubes of a triangular pattern in a steam generator. The accessible ways of the lance systems inside the steam generator are the annulus region which occupies the space between the outermost tubes and the inner wall of the steam generator, and the Blowdown Lane region (BdL) without tubes along the centerline of the steam generator. The lance system along the annulus employes a slidable guide support rail and a lance body. The guide support rail, which is composed of two parallel circular rods with a vertical distance, is tightly fixed inside the hand holes. The guide support rail extends from a hand hole at 0 degree to the other hand hole at 180 degree. The lance body is slideably held on the guide support rail by means of supporting holders which are attached on both the bottom and the upper plates of the lance body. The lance body is comprised of a nozzle block with a nozzle cylinder and a first drive means which makes sweeping motion of the nozzle cylinder, a second drive means which aligns the direction of nozzle jets from the nozzle cylinder toward the desired tube lanes by rotating the nozzle block in the horizontal plane, and two side wall supporting wheel assemblies attached to the outer surface of the lance body, rolling along the inner wall of the steam generator. For the transportation of the lance, two control cables which extend outward through the hand holes are attached to both ends of the lance body and are driven by a drive means with a powered drum. The lance system along the blowdown lane adopts a horizontal guide support rail and a lance body which can convey three nozzle blocks for emitting high pressure water in the 30, 90 and 150 degree directions. By utilizing the above two lance systems, the shadow zones around the tubes where the high pressure water does not reach are highly reduced

  17. Apparatus and method for applying an end plug to a fuel rod tube end

    International Nuclear Information System (INIS)

    Rieben, S.L.; Wylie, M.E.

    1987-01-01

    An apparatus is described for applying an end plug to a hollow end of a nuclear fuel rod tube, comprising: support means mounted for reciprocal movement between remote and adjacent positions relative to a nuclear fuel rod tube end to which an end plug is to be applied; guide means supported on the support means for movement; and drive means coupled to the support means and being actuatable for movement between retracted and extended positions for reciprocally moving the support means between its respective remote and adjacent positions. A method for applying an end plug to a hollow end of a nuclear fuel rod tube is also described

  18. Pick up screens for x-ray image intensifier tubes employing evaporated activated scintillator layer

    International Nuclear Information System (INIS)

    Spicer, W.E.

    1976-01-01

    The present invention relates in general to methods for making pick-up screens for x-ray image intensifier tubes and, more particularly, to an improved method wherein the x-ray fluorescent phosphor screen element is formed by evaporation of an alkali metal halide material in vacuum and condensing the evaporated material on an x-ray transparent portion of the x-ray intensifier tube, whereby a curved x-ray image pick-up screen is formed which has improved quantum efficiency and resolution. Such improved x-ray image intensifier tubes are especially useful for, but not limited in use to x-ray systems and for intensifying gamma ray images obtained in applications of nuclear medicine. 7 claims, 5 drawing figures

  19. In-pile Creep Tests of Zircaloy Tubing in the Studsvik R2 Reactor. Final Report

    International Nuclear Information System (INIS)

    Tomani, Hans; Lindeloew, Ulf

    2000-12-01

    In this report are presented the findings of a prototype creep test on Zr4 guide tube specimens exposed in-pile and out-of-pile and stressed by constant bending moments. The calculated initial deflection curvature caused by the applied bending moment agrees very well with the measured initial values. Furthermore, the measurement results show excellent consistency. The dominant impact of neutron irradiation is clearly demonstrated. After 3 cycles (∼1300 hours) the irradiation creep is 4 times as large as the thermal creep. This is the case at least when fresh tube material is used. Irradiation creep progresses steadily, but the creep rate is not quite constant during the 3 irradiation cycles. The thermal creep, on the other hand, quickly saturates and there is hardly any further deflection after the second cycle for the specimen situated above the core. A limitation with the rig has been that the tube deflection became limited by the rig carrier body of the rig in the neutron flux (core) that disqualified the results of a fourth irradiation cycle actually performed in the fall of 1998. The test method appears to be suitable for testing the bending creep of different guide tube materials or designs under PWR conditions

  20. Quantifying and Reducing Curve-Fitting Uncertainty in Isc

    Energy Technology Data Exchange (ETDEWEB)

    Campanelli, Mark; Duck, Benjamin; Emery, Keith

    2015-06-14

    Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data points can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.

  1. Matter-wave scattering and guiding by atomic arrays

    International Nuclear Information System (INIS)

    Vaishnav, J. Y.; Walls, J. D.; Apratim, M.; Heller, E. J.

    2007-01-01

    We investigate the possibility that linear arrays of atoms can guide matter waves, much as fiber optics guide light. We model the atomic line as a quasi-one-dimensional array of s-wave point scatterers embedded in two-dimensions. Our theoretical study reveals how matter-wave guiding arises from the interplay of scattering phenomena with bands and conduction along the array. We discuss the conditions under which a straight or curved array of atoms can guide a beam focused at one end of the array

  2. Effect of pore size on performance of monolithic tube chromatography of large biomolecules.

    Science.gov (United States)

    Podgornik, Ales; Hamachi, Masataka; Isakari, Yu; Yoshimoto, Noriko; Yamamoto, Shuichi

    2017-11-01

    Effect of pore size on the performance of ion-exchange monolith tube chromatography of large biomolecules was investigated. Radial flow 1 mL polymer based monolith tubes of different pore sizes (1.5, 2, and 6 μm) were tested with model samples such as 20 mer poly T-DNA, basic proteins, and acidic proteins (molecular weight 14 000-670 000). Pressure drop, pH transient, the number of binding site, dynamic binding capacity, and peak width were examined. Pressure drop-flow rate curves and dynamic binding capacity values were well correlated with the nominal pore size. While duration of the pH transient curves depends on the pore size, it was found that pH duration normalized on estimated surface area was constant, indicating that the ligand density is the same. This was also confirmed by the constant number of binding site values being independent of pore size. The peak width values were similar to those for axial flow monolith chromatography. These results showed that it is easy to scale up axial flow monolith chromatography to radial flow monolith tube chromatography by choosing the right pore size in terms of the pressure drop and capacity. © 2017 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  3. Guided flows in coronal magnetic flux tubes

    Science.gov (United States)

    Petralia, A.; Reale, F.; Testa, P.

    2018-01-01

    Context. There is evidence that coronal plasma flows break down into fragments and become laminar. Aims: We investigate this effect by modelling flows confined along magnetic channels. Methods: We consider a full magnetohydrodynamic (MHD) model of a solar atmosphere box with a dipole magnetic field. We compare the propagation of a cylindrical flow perfectly aligned with the field to that of another flow with a slight misalignment. We assume a flow speed of 200 km s-1 and an ambient magnetic field of 30 G. Results: We find that although the aligned flow maintains its cylindrical symmetry while it travels along the magnetic tube, the misaligned one is rapidly squashed on one side, becoming laminar and eventually fragmented because of the interaction and back-reaction of the magnetic field. This model could explain an observation made by the Atmospheric Imaging Assembly on board the Solar Dynamics Observatory of erupted fragments that fall back onto the solar surface as thin and elongated strands and end up in a hedge-like configuration. Conclusions: The initial alignment of plasma flow plays an important role in determining the possible laminar structure and fragmentation of flows while they travel along magnetic channels. Movies are available in electronic form at http://www.aanda.org

  4. Multistage Coupling of Laser-Wakefield Accelerators with Curved Plasma Channels

    Science.gov (United States)

    Luo, J.; Chen, M.; Wu, W. Y.; Weng, S. M.; Sheng, Z. M.; Schroeder, C. B.; Jaroszynski, D. A.; Esarey, E.; Leemans, W. P.; Mori, W. B.; Zhang, J.

    2018-04-01

    Multistage coupling of laser-wakefield accelerators is essential to overcome laser energy depletion for high-energy applications such as TeV-level electron-positron colliders. Current staging schemes feed subsequent laser pulses into stages using plasma mirrors while controlling electron beam focusing with plasma lenses. Here a more compact and efficient scheme is proposed to realize the simultaneous coupling of the electron beam and the laser pulse into a second stage. A partly curved channel, integrating a straight acceleration stage with a curved transition segment, is used to guide a fresh laser pulse into a subsequent straight channel, while the electrons continue straight. This scheme benefits from a shorter coupling distance and continuous guiding of the electrons in plasma while suppressing transverse beam dispersion. Particle-in-cell simulations demonstrate that the electron beam from a previous stage can be efficiently injected into a subsequent stage for further acceleration while maintaining high capture efficiency, stability, and beam quality.

  5. Family Experiences With Feeding Tubes in Neurologic Impairment: A Systematic Review.

    Science.gov (United States)

    Nelson, Katherine E; Lacombe-Duncan, Ashley; Cohen, Eyal; Nicholas, David B; Rosella, Laura C; Guttmann, Astrid; Mahant, Sanjay

    2015-07-01

    Gastrostomy tubes (G-tubes) are frequently used to provide enteral nutrition for children who have neurologic impairment. Understanding the impact of G-tubes from the family's perspective will inform decision-making and improve support from health care providers. This study explored the experiences of families after G-tube placement in children with neurologic impairment. We conducted a systematic review of English-language qualitative primary research studies describing family experiences after G-tube placement. Six electronic databases were searched from inception to June 2014. Two authors independently screened and identified relevant studies, evaluated quality of reporting by using the Consolidated Criteria for Reporting Qualitative Research tool, and extracted data. Overarching concepts were developed by using thematic analysis. From 2674 screened abstracts, 84 texts were reviewed, and 13 studies met the inclusion criteria. G-tubes affect the lives of children, parents, and the family unit in many ways, both positive and negative. Improvements and challenges were described for children's health and happiness, for parental caregiving and stress, and for logistics and bonding within the family. G-tube feeding also changed relationships within the family, between the family and the medical system, and between the family and the outside world. Furthermore, experiences varied, with different families framing similar concepts as positive and negative. G-tube placement has diverse effects on daily life for children with neurologic impairment and their families. Clinicians may use the themes identified in this study to guide conversations with families about their values, experiences, and expectations before and after G-tube placement. Copyright © 2015 by the American Academy of Pediatrics.

  6. The maximum contraceptive prevalence 'demand curve': guiding discussions on programmatic investments.

    Science.gov (United States)

    Weinberger, Michelle; Sonneveldt, Emily; Stover, John

    2017-12-22

    Most frameworks for family planning include both access and demand interventions. Understanding how these two are linked and when each should be prioritized is difficult. The maximum contraceptive prevalence 'demand curve' was created based on a relationship between the modern contraceptive prevalence rate (mCPR) and mean ideal number of children to allow for a quantitative assessment of the balance between access and demand interventions. The curve represents the maximum mCPR that is likely to be seen given fertility intentions and related norms and constructs that influence contraceptive use. The gap between a country's mCPR and this maximum is referred to as the 'potential use gap.' This concept can be used by countries to prioritize access investments where the gap is large, and discuss implications for future contraceptive use where the gap is small. It is also used within the FP Goals model to ensure mCPR growth from access interventions does not exceed available demand.

  7. A combined experimental and FE analysis procedure to evaluate tensile behavior of zircaloy pressure tubes

    International Nuclear Information System (INIS)

    Samal, M.K.; Vaze, K.K.; Balakrishnan, K.S.; Anantharaman, S.

    2012-01-01

    Determination of transverse mechanical properties from the ring type of specimens directly machined from the nuclear reactor pressure tubes is not straightforward because of the presence of combined membrane as well as bending stresses arising in the loaded condition. In this work, we have performed ring-tensile tests on the un-irradiated ring tensile specimen using two split semi-cylindrical mandrels as the loading device. A 3-D finite element (FE) analysis was performed in order to determine the material true stress-strain curve by comparing experimental load-displacement data with those predicted by FE analysis. In order to validate the methodology, miniaturized tensile specimens were machined from these tubes and tested. It was observed that the stress-strain data as obtained from ring tensile specimen could describe the load displacement curve of the miniaturized flat tensile specimen very well. (author)

  8. Wave propagation in plasma-filled wave-guide

    International Nuclear Information System (INIS)

    Leprince, Philippe

    1966-01-01

    This research thesis reports the study of wave propagation along a plasma column without external magnetic field. The author first present and comment various theoretical results, and dispersion curves plotted for the main modes (particularly, the bipolar mode). He tries to define fundamental magnitudes which characterise a plasma-filled wave-guide. He reports the comparison of some experimental results with the previous theoretical results. Based on the study of the bipolar mode, the author develops a method of measurement of plasma column density. In the last part, the author reports the study of the resonance of a plasma-containing cavity. Several resonances are highlighted and new dispersion curves are plotted by using a varying length cavity. He also addresses the coupling of plasma modes with guide modes, and thus indicates the shape of Brillouin diagrams for a plasma-filled wave-guide. Moreover, some phenomena highlighted during plasma column density measurements by using the cavity method could then be explained [fr

  9. Dosimetry of a gamma beam - 650 60Co irradiator. 3. Mapping of the isodose curves in the internal cavity

    International Nuclear Information System (INIS)

    Escobedo, J.F.; Nascimento Filho, V.F. do; Ferraz, E.S.B.

    1981-01-01

    The Gammabeam-650 60 Co irradiator, containing 29,080 curies (April 1 sup(st), 1974), made by Atomic Energy of Canada Limited and in operation at CENA - Piracicaba, Sao Paulo, Brazil, basically has a block of lead for storage and shielding of the radioactive capsules and 12 vertical pneumatic tubes to maintain them in exposure position. These tubes form a cylindrical internal cavity with varying diameter between 10 and 84 cm. The isodose curves were determined for the geometries of 3, 6 and 12 actives tubes and 42 and 84 cm of diameter using the Fricke's chemical dosimeter. (Author) [pt

  10. Ultrasonic guided waves in eccentric annular pipes

    International Nuclear Information System (INIS)

    Pattanayak, Roson Kumar; Balasubramaniam, Krishnan; Rajagopal, Prabhu

    2014-01-01

    This paper studies the feasibility of using ultrasonic guided waves to rapidly inspect tubes and pipes for possible eccentricity. While guided waves are well established in the long range inspection of structures such as pipes and plates, studies for more complex cross sections are limited and analytical solutions are often difficult to obtain. Recent developments have made the Semi Analytical Finite Element (SAFE) method widely accessible for researchers to study guided wave properties in complex structures. Here the SAFE method is used to study the effect of eccentricity on the modal structures and velocities of lower order guided wave modes in thin pipes of diameters typically of interest to the industry. Results are validated using experiments. The paper demonstrates that even a small eccentricity in the pipe can strongly affect guided wave mode structures and velocities and hence shows potential for pipe eccentricity inspection

  11. Modeling of three-dimensional diffusible resistors with the one-dimensional tube multiplexing method

    International Nuclear Information System (INIS)

    Gillet, Jean-Numa; Degorce, Jean-Yves; Meunier, Michel

    2009-01-01

    Electronic-behavior modeling of three-dimensional (3D) p + -π-p + and n + -ν-n + semiconducting diffusible devices with highly accurate resistances for the design of analog resistors, which are compatible with the CMOS (complementary-metal-oxide-semiconductor) technologies, is performed in three dimensions with the fast tube multiplexing method (TMM). The current–voltage (I–V) curve of a silicon device is usually computed with traditional device simulators of technology computer-aided design (TCAD) based on the finite-element method (FEM). However, for the design of 3D p + -π-p + and n + -ν-n + diffusible resistors, they show a high computational cost and convergence that may fail with fully non-separable 3D dopant concentration profiles as observed in many diffusible resistors resulting from laser trimming. These problems are avoided with the proposed TMM, which divides the 3D resistor into one-dimensional (1D) thin tubes with longitudinal axes following the main orientation of the average electrical field in the tubes. The I–V curve is rapidly obtained for a device with a realistic 3D dopant profile, since a system of three first-order ordinary differential equations has to be solved for each 1D multiplexed tube with the TMM instead of three second-order partial differential equations in the traditional TCADs. Simulations with the TMM are successfully compared to experimental results from silicon-based 3D resistors fabricated by laser-induced dopant diffusion in the gaps of MOSFETs (metal-oxide-semiconductor field-effect transistors) without initial gate. Using thin tubes with other shapes than parallelepipeds as ring segments with toroidal lateral surfaces, the TMM can be generalized to electronic devices with other types of 3D diffusible microstructures

  12. 21 CFR 868.5800 - Tracheostomy tube and tube cuff.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheostomy tube and tube cuff. 868.5800 Section... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Therapeutic Devices § 868.5800 Tracheostomy tube and tube cuff. (a) Identification. A tracheostomy tube and tube cuff is a device intended to be placed into a...

  13. Tube plug

    International Nuclear Information System (INIS)

    Zafred, P. R.

    1985-01-01

    The tube plug comprises a one piece mechanical plug having one open end and one closed end which is capable of being inserted in a heat exchange tube and internally expanded into contact with the inside surface of the heat exchange tube for preventing flow of a coolant through the heat exchange tube. The tube plug also comprises a groove extending around the outside circumference thereof which has an elastomeric material disposed in the groove for enhancing the seal between the tube plug and the tube

  14. Numerical Investigation of the Flow Structure in a Kaplan Draft Tube at Part Load

    Science.gov (United States)

    Maddahian, R.; Cervantes, M. J.; Sotoudeh, N.

    2016-11-01

    This research presents numerical simulation of the unsteady flow field inside the draft tube of a Kaplan turbine at part load condition. Due to curvature of streamlines, the ordinary two-equations turbulence models fail to predict the flow features. Therefore, a modification of the Shear Stress Transport (SST-SAS) model is utilized to approximate the turbulent stresses. A guide vane, complete runner and draft tube are considered to insure the real boundary conditions at the draft tube inlet. The outlet boundary is assumed to discharge into the atmosphere. The obtained pressure fluctuations inside the draft tube are in good agreement with available experimental data. In order to further investigate the RVR formation and its movement, the λ2 criterion, relating the position of the vortex core and strength to the second largest Eigen value of the velocity gradient tensor, is employed. The method used for vortex identification shows the flow structure and vortex motion inside the draft tube accurately.

  15. Ultrasonic inspection of tube to tube plate welds

    International Nuclear Information System (INIS)

    Telford, D.W.; Peat, T.S.

    1985-01-01

    To monitor the deterioration of a weld between a tube and tube plate which has been repaired by a repair sleeve inside the tube and brazed at one end to the tube, ultrasound from a crystal at the end of a rod is launched, in the form of Lamb-type waves, into the tube through the braze and allowed to travel along the tube to the weld and be reflected back along the tube. The technique may also be used for the type of heat exchanger in which, during construction, the tubes are welded to the tube plate via external sleeves in which case the ultrasound is used in a similar manner to inspect the sleeve/tube plate weld. an electromagnetic transducer may be used to generate the ultrasound. The ultrasonic head comprising the crystal and an acoustic baffle is mounted on a Perspex (RTM) rod which may be rotated by a stepping motor. Echo signals from the region of deterioration may be isolated by use of a time gate in the receiver. The device primarily detects circumferentially orientated cracks, and may be used in heat exchangers in nuclear power plants. (author)

  16. Laced permanent magnet quadrupole drift tube magnets

    International Nuclear Information System (INIS)

    Feinberg, B.; Behrsing, G.U.; Halbach, K.; Marks, J.S.; Morrison, M.E.; Nelson, D.H.

    1988-10-01

    A laced permanent magnet quadrupole drift tube magnet has been constructed for a proof-of-principle test. The magnet is a conventional tape-wound quadrupole electromagnet, using iron pole- pieces, with the addition of permanent magnet material (neodymium iron) between the poles to reduce the effects of saturation. The iron is preloaded with magnetic flux generated by the permanent magnet material, resulting in an asymmetrical saturation curve. Since the polarity of the quadrupole magnets in a drift tube linac is not reversed we can take advantage of this asymmetrical saturation to provide greater focusing strength. The magnet configuration has been optimized and the vanadium permendur poles needed in a conventional quadrupole have been replaced with iron poles. The use of permanent magnet material has allowed us to increase the focusing strength of the magnet by about 20% over that of a conventional tape-wound quadrupole. Comparisons will be made between this magnet and the conventional tape-wound quadrupole. 3 refs., 5 figs

  17. Adaptation, testing and application of the two-dimensional FE computer program system for steam generator tube testing

    International Nuclear Information System (INIS)

    Betzold, K.

    1987-01-01

    The 2d-FE computing program system, taken over by EPRI, is used for the improvement of the eddy current test of steam generator heating tubes. The investigations focus on test tasks in the area of the tube plate and the scrap mark; among them: accumulation of mud in the cracking area and above the tube plate; circulating slots with and without accumulation of mud. The interaction of the factors of influence given by the test object and the parameters selectable by the tester as for example coil length and base space for absolute coils and differential coils as well as test frequencies are calculated and the form of the signal locus curves and the dynamic curves are listed in a sample catalogue. It is demonstrated with selected examples that the sample catalogue contributes to the test-specific design of the coil and to the choice of the test frequencies; interpretation of measured signals; deepening of the knowledge of the physical processe in eddy current tests. (orig./HP) [de

  18. Water experiments on thermal striping in reactor vessel of advanced sodium-cooled fast reactor. Influence of flow collector of backup CR guide tube

    International Nuclear Information System (INIS)

    Kobayashi, Jun; Ezure, Toshiki; Tanaka, Masaaki; Kamide, Hideki

    2016-01-01

    Design study of an advanced large-scale sodium-cooled fast reactor (SFR) has been conducted in JAEA. In the region between the bottom of the Upper Internal Structure (UIS) and the core outlet, the hot sodium from the fuel subassembly mixes with the cold sodium from the neighbor control rod (CR) channel. Therefore, temperature fluctuation due to mixing fluids at different temperatures may cause high cycle thermal fatigue at the bottom of the UIS. In the advanced design, installation of a flow guide structure named Flow-Collector (FC) to the backup control rod (BCR) guide tube is considered to enhance reliable operation of self-actuated shutdown system (SASS) and to ensure reactor shutdown operation. Previously, water experiments without the FC model had been examined in JAEA to investigate effective countermeasures to the significant temperature fluctuation generation at the bottom of the UIS. Since the FC may affect the thermal mixing behavior at the bottom of the UIS, influence of the FC on characteristics of the temperature fluctuation around the BCR channels was investigated using a water experimental facility with structure model of the FC. Through the experiment, small influence of the FC on the temperature fluctuation distribution at the bottom of the UIS was indicated. (author)

  19. Genetic relationship between lactation curve traits of dairy cattle in ...

    African Journals Online (AJOL)

    Wasike Chrislukovian

    2014-08-23

    Aug 23, 2014 ... Lactation milk yield is an important trait in selection of dairy cattle all ... affect functional traits such as fertility, somatic cell count and mastitis, ... explain physiological issues reported in Kenyan herds and guide future selection decisions. The correlation between milk yield and lactation curve traits has not ...

  20. Criticality guide. I - Introduction to criticality. II - Practical rules. III - Curves; Guide de criticite. I - Introduction a la criticite. II - Regles pratiques. III - Courbes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1967-07-01

    Somme elements of neutronics are presented in a simple and often intuitive way; the 'K infinite' and 'K effective' formulae are derived and discussed. The limiting solid angle method is explained and some simple formulae proposed for evaluating the interaction between 'fissile units'. The general principles used in studying the safety of nuclear installations using fissile matter are given. Practical rules, critical mass and critical geometry curves as well as all the numerical values required for normal criticality calculations are given for plutonium and uranium at various degrees of enrichment. This guide is not intended to produce experts in criticality and cannot replace the advice which can be given by specialists of a science which is still expanding rapidly. It should however simplify the task of these specialists by familiarising with these problems both the engineers and scientists in charge of the design of installations using fissile matter, and the persons in charge of their operation. (author) [French] Des elements de neutronique sont exposes d'une fapon simple et souvent intuitive les formules du 'K infini' et du 'K effectif' sont etablies et commentees. La 'methode de l'angle solide limite' est expliquee et des formules simples proposees pour evaluer l'interaction entre des 'unites fissiles'. Les principes generaux utilises dans les etudes de surete nucleaire d'installation, mettant en ceuvre des matieres fissiles, sont donnes. Des regles pratiques, des courbes de masse et geometrie critiques ainsi que toutes les valeurs numeriques necessaires aux calculs usuels de criticite sont fournies pour du plutonium et de l'uranium a divers enrichissements. Ce guide n'a pas la pretention de former des experts en criticite et ne doit pas dispenser de s'entourer de l'avis de specialistes dans une science encore en pleine evolution. II doit simplement faciliter la tache de ceux-ci, en familiarisant avec ces problemes les ingenieurs charges de la conception des

  1. Experimental creep behaviour determination of cladding tube materials under multi-axial loadings

    International Nuclear Information System (INIS)

    Grosjean, Catherine; Poquillon, Dominique; Salabura, Jean-Claude; Cloue, Jean-Marc

    2009-01-01

    Cladding tubes are structural parts of nuclear plants, submitted to complex thermomechanical loadings. Thus, it is necessary to know and predict their behaviour to preserve their integrity and to enhance their lifetime. Therefore, a new experimental device has been developed to control the load path under multi-axial load conditions. The apparatus is designed to determine the thermomechanical behaviour of zirconium alloys used for cladding tubes. First results are presented. Creep tests with different biaxial loadings were performed. Results are analysed in terms of thermal expansion and of creep strain. The anisotropy of the material is revealed and iso-creep strain curves are given.

  2. Heat Exchanger Tube to Tube Sheet Joints Corrosion Behavior

    Directory of Open Access Journals (Sweden)

    M. Iancu

    2013-03-01

    Full Text Available Paper presents the studies made by the authors above the tube to tube sheet fittings of heat exchanger with fixed covers from hydrofining oil reforming unit. Tube fittings are critical zones for heat exchangers failures. On a device made from material tube and tube sheet at real joints dimensions were establish axial compression force and traction force at which tube is extracted from expanded joint. Were used two shapes joints with two types of fittings surfaces, one with smooth hole of tube sheet and other in which on boring surface we made a groove. From extracted expanded tube zones were made samples for corrosion tests in order to establish the corrosion rate, corrosion potential and corrosion current in working mediums such as hydrofining oil and industrial water at different temperatures. The corrosion rate values and the temperature influence are important to evaluate joints durability and also the results obtained shows that the boring tube sheet shape with a groove on hole tube shape presents a better corrosion behavior then the shape with smooth hole tube sheet.

  3. Flow in curved ducts of varying cross-section

    Science.gov (United States)

    Sotiropoulos, F.; Patel, V. C.

    1992-07-01

    Two numerical methods for solving the incompressible Navier-Stokes equations are compared with each other by applying them to calculate laminar and turbulent flows through curved ducts of regular cross-section. Detailed comparisons, between the computed solutions and experimental data, are carried out in order to validate the two methods and to identify their relative merits and disadvantages. Based on the conclusions of this comparative study a numerical method is developed for simulating viscous flows through curved ducts of varying cross-sections. The proposed method is capable of simulating the near-wall turbulence using fine computational meshes across the sublayer in conjunction with a two-layer k-epsilon model. Numerical solutions are obtained for: (1) a straight transition duct geometry, and (2) a hydroturbine draft-tube configuration at model scale Reynolds number for various inlet swirl intensities. The report also provides a detailed literature survey that summarizes all the experimental and computational work in the area of duct flows.

  4. Ground states, magnetization plateaus and bipartite entanglement of frustrated spin-1/2 Ising-Heisenberg and Heisenberg triangular tubes

    International Nuclear Information System (INIS)

    Alécio, Raphael C.; Lyra, Marcelo L.; Strečka, Jozef

    2016-01-01

    The ground-state phase diagram, magnetization process and bipartite entanglement of the frustrated spin-1/2 Ising-Heisenberg and Heisenberg triangular tube (three-leg ladder) are investigated in a non-zero external magnetic field. The exact ground-state phase diagram of the spin-1/2 Ising-Heisenberg tube with Heisenberg intra-rung and Ising inter-rung couplings consists of six distinct gapped phases, which manifest themselves in a magnetization curve as intermediate plateaus at zero, one-third and two-thirds of the saturation magnetization. Four out of six available ground states exhibit quantum entanglement between two spins from the same triangular unit evidenced by a non-zero concurrence. Density-matrix renormalization group calculations are used in order to construct the ground-state phase diagram of the analogous but purely quantum spin-1/2 Heisenberg tube with Heisenberg intra- and inter-rung couplings, which consists of four gapped and three gapless phases. The Heisenberg tube shows a continuous change of the magnetization instead of a plateau at zero magnetization, while the intermediate one-third and two-thirds plateaus may be present or not in the zero-temperature magnetization curve. - Highlights: • Ground-state properties of Ising-Heisenberg and full Heisenberg spin tubes are studied. • Phases with 1/3 and 2/3 magnetization plateaus are present in both models. • We unveil the region in the parameter space on which inter-rung quantum fluctuations are relevant. • The full Heisenberg tube exhibits quantum bipartite entanglement between intra- as well as inter-rung spins.

  5. Tube spacer grid for a heat-exchanger tube bundle

    International Nuclear Information System (INIS)

    Scheidl, H.

    1976-01-01

    A tube spacer grid for a heat-exchanger tube bundle is formed by an annular grid frame having a groove formed in its inner surface in which the interspaced grid bars have their ends positioned and held in interspaced relationship by short sections of tubes passed through holes axially formed in the grid frame so that the tubes are positioned between the ends of the grid bars in the grooves. The tube sections may be cut from the same tubes used to form the tube bundle. 5 claims, 3 drawing figures

  6. Savannah River reactor process water heat exchanger tube structural integrity margin Task Number 92-005-1

    International Nuclear Information System (INIS)

    Mertz, G.E.; Barnes, D.M.; Sindelar, R.L.

    1992-02-01

    Twelve process water heat exchangers are designed to remove heat generated in the reactor tank. Each heat exchanger has approximately 9000, 1/2 inch diameter x 0.049 inches thick tubes. Minimum structural tubing requirements and the leak rate through postulated tubing defects are developed in this report A comparison of the structural requirements and the defect size calculated to produce leak rates of 0.5 lbs./day demonstrate adequate structural margins against gross tube rupture. Commercial nuclear experience with pressurized water reactor (PWR) steam generator plugging criteria are used for guidance in performing this analysis. It is important to note that the SRS reactors are low energy systems with normal operating pressures of 203 psig at 130 degree F while the PWR is a high energy system with operating pressures near 2200 psig at 600 degree F. Clearly the PVM steam generator has loadings which are more severe than the SRS heat exchangers. Consistent with the Regulatory Guide 1.121 criteria both wastage (wall thinning) and cracking are addressed. Structural limits on wall thinning and crack size are developed to preclude gross rupture. ASME Section XI criteria, with the factors of safety recommended by Regulatory Guide 1.121 are used to develop the allowable crack size criteria. Normal operating conditions (pressure, dead weight, and hydraulic drag) are considered with seismic and water hammer accident conditions. Both the wall thinning and crack size criteria are developed for the end-of-evaluation period. Allowances for corrosion, wear, or crack growth have not been included in this analysis Structurally, the tubing is over designed and can tolerate large defects with adequate margins against gross rupture. The structural margins of heat exchanger tubing are evident by contrasting the tubing's structural capacity, per the ASME Code, with its operating conditions/configuration

  7. CT-guided interventions in children; Computertomografisch gesteuerte Interventionen bei Kindern

    Energy Technology Data Exchange (ETDEWEB)

    Honnef, D.; Wildberger, J.E.; Schubert, H.; Hohl, C.; Guenther, R.W.; Mahnken, A. [Technische Hochschule Aachen (Germany). Klinik fuer Radiologische Diagnostik

    2007-06-15

    In pediatric CT-guided interventions specific features have to be taken into account. Due to a lack of cooperation or limited ability to cooperate, procedures are often performed using analgosedation or general anesthesia. To provide radiation protection, justified indication for CT-guided intervention is necessary and sonography and MRI are to be preferred whenever possible. CT examinations also need to be dose-adapted with sequential scanning and a tube voltage and tube current reduction compared to pediatric diagnostic CT studies must be ensured. Gonad shields are recommended for male patients. Biopsy device selection depends on the assumed tumor entity since histology and also immunohistochemical, molecular pathological and cytogenetical analysis are necessary to differentiate pediatric tumors (small, round, blue cell tumors). In addition to diagnostic procedures, therapeutic interventions (drainage, injection therapies, neurolysis, and radiofrequency ablation) can also be used in children and can provide an alternative to surgery in selected cases. With justified indications and precise performance, CT-guided interventions can be successful in pediatric patients with limited risks. (orig.)

  8. Analysis of reverse flow in inverted U-tubes of steam generator under natural circulation condition

    International Nuclear Information System (INIS)

    Yang Ruichang; Liu Ruolei; Liu Jinggong; Qin Shiwei

    2008-01-01

    In this paper, we report on the analysis of reverse flow in inverted U-tubes of a steam generator under natural circulation condition. The mechanism of reverse flow in inverted U-tubes of the steam generator with natural circulation is graphically analyzed by using the full-range characteristic curve of parallel U-tubes. The mathematical model and numerical calculation method for analyzing the reverse flow in inverted U-tubes of the steam generator with natural circulation have been developed. The reverse flow in an inverted U-tube steam generator of a simulated pressurized water reactor with natural circulation in analyzed. Through the calculation, the mass flow rates of normal and reverse flows in individual U-tubes are obtained. The predicted sharp drop of the fluid temperature in the inlet plenum of the steam generator due to reverse flow agrees very well with the experimental data. This indicates that the developed mathematical model and solution method can be used to correctly predict the reverse flow in the inverted U-tubes of the steam generator with natural circulation. The obtained results also show that in the analysis of natural circulation flow in the primary circuit, the reverse flow in the inverted U-tubes of the steam generator must be taken into account. (author)

  9. On the evaluation of lifetime of evaporative tubes of once-through steam generators at steam-generating surface temperature oscillations in the burnout region

    International Nuclear Information System (INIS)

    Vorob'ev, V.A.; Loshchinin, V.M.; Remizov, O.V.

    1978-01-01

    Suggested is a method for evaluation of a stressed state of evaporation tubes of once-through steam generators at temperature oscillations in the burnout region. Calculated is the amplitude of steam-generating surface temperature oscillations in the burnout region depending on the frequency of a liquid-steam boundary transfer and on this basis determined are thermal stresses in a tube wall. Knowing a fatigue curve gives the possibility to evaluate a heat transfer tube lifetime

  10. Environmentally assisted fatigue evaluation model of alloy 690 steam generator tube in high temperature water

    International Nuclear Information System (INIS)

    Tan Jibo; Wu Xinqiang; Han Enhou; Wang Xiang; Liu Xiaoqiang; Xu Xuelian

    2015-01-01

    Nickel-based alloy 690 has been widely used as steam generator tube in light water reactor (LWR) nuclear power plants, which may suffer from corrosion fatigue during long-term service. Many researches and operating experience indicated that the effect of LWR environment could significantly reduce the fatigue life of structural materials. However. such an environmental degradation effect was not fully addressed in the current ASME code design fatigue curves. Therefore, the Regulatory Guide 1.207 issued by US NRC required a new NPP have to incorporate the environment effects into fatigue analyses. In the last few decades, researchers in USA and Japan systematically investigated the corrosion fatigue behavior of nuclear-grade structural materials in LWR environment. Then, ANL model and JSME model were proposed, which incorporated environmental effects, including temperature, dissolved oxygen (DO) and strain rate for the nickel-based alloys. Due to lack of experiment data on domestic materials, there is no related environmental fatigue design model in China. In the present work, based on the corrosion fatigue tests of a kind of boat-shaped specimen in borated and lithiated high temperature water, the corrosion fatigue behavior and environmentally assisted cracking mechanism of domestic Alloy 690 steam generator tube have been investigate. An IMR model for the nickel-based alloy was proposed. The environmental fatigue life correction factor (F en ) was established, which addressed the environmental factors, including temperature, strain rate and dissolved oxygen. The method to evaluate environmental fatigue damage of structural materials in NPPs was proposed. (authors)

  11. Design and implementation of a simple on-line time-activity curve detector for [O-15] water PET studies

    International Nuclear Information System (INIS)

    Wollenweber, S.D.; Hichwa, R.D.; Ponto, L.L.B.

    1996-01-01

    A simple, automated on-line detector system has been fabricated and implemented to detect the arterial time-activity curve (TAC) for water PET studies. This system offers two significant improvements over existing systems: a pump mechanism is not required to control arterial blood flow through the detector and dispersion correction of the time-activity curve is unnecessary. The positrons emanating from a thin-walled, 0.134 cm inner-diameter plastic tube are detected by a 0.5 cm wide by 1.0 cm long by 0.1 cm thick plastic scintillator mounted to a miniature PMT. Photon background is shielded by a 2.0 cm thick cylindrical lead shield. Mean cerebral blood flow (mCBF) calculated from the TAC determined by 1-second automated sampling was compared to that calculated from every 5-second integrated manual samples. Improvements in timing resolution (1-sec vs. 5-sec) cause small but significant differences between the two sampling methods. Dispersion is minimized due to small tubing diameters, short lengths of tubing between the radial arterial sampling site and the detector and the presence of a 3-way valve 10 cm proximal to the detector

  12. Quantifying and Reducing Curve-Fitting Uncertainty in Isc: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Campanelli, Mark; Duck, Benjamin; Emery, Keith

    2015-09-28

    Current-voltage (I-V) curve measurements of photovoltaic (PV) devices are used to determine performance parameters and to establish traceable calibration chains. Measurement standards specify localized curve fitting methods, e.g., straight-line interpolation/extrapolation of the I-V curve points near short-circuit current, Isc. By considering such fits as statistical linear regressions, uncertainties in the performance parameters are readily quantified. However, the legitimacy of such a computed uncertainty requires that the model be a valid (local) representation of the I-V curve and that the noise be sufficiently well characterized. Using more data points often has the advantage of lowering the uncertainty. However, more data points can make the uncertainty in the fit arbitrarily small, and this fit uncertainty misses the dominant residual uncertainty due to so-called model discrepancy. Using objective Bayesian linear regression for straight-line fits for Isc, we investigate an evidence-based method to automatically choose data windows of I-V points with reduced model discrepancy. We also investigate noise effects. Uncertainties, aligned with the Guide to the Expression of Uncertainty in Measurement (GUM), are quantified throughout.

  13. Evaluation of sampling schemes for in-service inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Hanlen, R.C.

    1990-03-01

    This report is a follow-on of work initially sponsored by the US Nuclear Regulatory Commission (Bowen et al. 1989). The work presented here is funded by EPRI and is jointly sponsored by the Electric Power Research Institute (EPRI) and the US Nuclear Regulatory Commission (NRC). The goal of this research was to evaluate fourteen sampling schemes or plans. The main criterion used for evaluating plan performance was the effectiveness for sampling, detecting and plugging defective tubes. The performance criterion was evaluated across several choices of distributions of degraded/defective tubes, probability of detection (POD) curves and eddy-current sizing models. Conclusions from this study are dependent upon the tube defect distributions, sample size, and expansion rules considered. As degraded/defective tubes form ''clusters'' (i.e., maps 6A, 8A and 13A), the smaller sample sizes provide a capability of detecting and sizing defective tubes that approaches 100% inspection. When there is little or no clustering (i.e., maps 1A, 20 and 21), sample efficiency is approximately equal to the initial sample size taken. Thee is an indication (though not statistically significant) that the systematic sampling plans are better than the random sampling plans for equivalent initial sample size. There was no indication of an effect due to modifying the threshold value for the second stage expansion. The lack of an indication is likely due to the specific tube flaw sizes considered for the six tube maps. 1 ref., 11 figs., 19 tabs

  14. Principal-Generated YouTube Video as a Method of Improving Parental Involvement

    Science.gov (United States)

    Richards, Joey

    2013-01-01

    The purpose of this study was to evaluate the involvement level of parents and reveal whether principal-generated YouTube videos for regular communication would enhance levels of parental involvement at one North Texas Christian Middle School (pseudonym). The following questions guided this study: 1. What is the beginning level of parental…

  15. Deformation behavior of Zircaloy-4 cladding tubes under inert gas conditions in the temperature range from 600 to 12000C

    International Nuclear Information System (INIS)

    Hofmann, P.; Raff, S.; Gausmann, G.

    1981-07-01

    Within the temperature range from 600 0 to 1200 0 isothermal, isobaric creep rupture experiments were performed under inert gas with short Zircaloy-4 tube specimens in order to obtain experimental data supporting the development of the NORA cladding tube deformation model. The values of the tube inner pressure were so selected that the time-to-failure values varied between 2 and 2000 s. The corresponding creep rupture curves are indicated. Besides the temperature and the burst pressure the development of deformation over time of the tube specimens was measured. This allowed to draw diagrams of stress, strain rate and strain. On account of the type of specimen heating applied (radiation heating) the temperature difference at the cladding tube circumference is very small ( [de

  16. Assessment of CCFL model of RELAP5/MOD3 against simple vertical tubes and rod bundle tests

    International Nuclear Information System (INIS)

    Cho, Sung Jae; Arne, Nam Sung; Chung, Bub Dong; Kim, Hho Jung

    1991-01-01

    The CCFL model used in RELAP5/MOD3 version 5m5 has been assessed against simple vertical tubes and rod bundle tests performed at a facility of Korea Atomic Energy Research Institute. The effect of changes in tube diameter and nodalization of tube section were investigated. The roles of interfacial drags on the flooding characteristics are discussed. Difference between the calculation and the experiment are also discussed. A comparison between model assessment results and the test data showed that the calculated value lay well on the experimental flooding curve specified by user, but the pressure jump before onset of flooding was not calculated

  17. Device for guiding a subthermal neutron beam and focussing device made of micro-neutron guides

    International Nuclear Information System (INIS)

    Marx, D.

    1977-01-01

    The invention concerns a device for guiding, in particular for diverting, a subthermal neutron beam with curved boundary surfaces at least in one level, whose sides towards the neutron beam are covered with at least one coating which reflects the subthermal neutrons completely. (orig./RW) [de

  18. Proper Orthogonal Decomposition of Pressure Fields in a Draft Tube Cone of the Francis (Tokke) Turbine Model

    International Nuclear Information System (INIS)

    Stefan, D; Rudolf, P

    2015-01-01

    The simulations of high head Francis turbine model (Tokke) are performed for three operating conditions - Part Load, Best Efficiency Point (BEP) and Full Load using software Ansys Fluent R15 and alternatively OpenFOAM 2.2.2. For both solvers the simulations employ Realizable k-e turbulence model. The unsteady pressure pulsations of pressure signal from two monitoring points situated in the draft tube cone and one behind the guide vanes are evaluated for all three operating conditions in order to compare frequencies and amplitudes with the experimental results. The computed velocity fields are compared with the experimental ones using LDA measurements in two locations situated in the draft tube cone. The proper orthogonal decomposition (POD) is applied on a longitudinal slice through the draft tube cone. The unsteady static pressure fields are decomposed and a spatio-temporal behavior of modes is correlated with amplitude-frequency results obtained from the pressure signal in monitoring points. The main application of POD is to describe which modes are related to an interaction between rotor (turbine runner) and stator (spiral casing and guide vanes) and cause dynamic flow behavior in the draft tube. The numerically computed efficiency is correlated with the experimental one in order to verify the simulation accuracy

  19. Establishing Decision Trees for Predicting Successful Postpyloric Nasoenteric Tube Placement in Critically Ill Patients.

    Science.gov (United States)

    Chen, Weisheng; Sun, Cheng; Wei, Ru; Zhang, Yanlin; Ye, Heng; Chi, Ruibin; Zhang, Yichen; Hu, Bei; Lv, Bo; Chen, Lifang; Zhang, Xiunong; Lan, Huilan; Chen, Chunbo

    2018-01-01

    Despite the use of prokinetic agents, the overall success rate for postpyloric placement via a self-propelled spiral nasoenteric tube is quite low. This retrospective study was conducted in the intensive care units of 11 university hospitals from 2006 to 2016 among adult patients who underwent self-propelled spiral nasoenteric tube insertion. Success was defined as postpyloric nasoenteric tube placement confirmed by abdominal x-ray scan 24 hours after tube insertion. Chi-square automatic interaction detection (CHAID), simple classification and regression trees (SimpleCart), and J48 methodologies were used to develop decision tree models, and multiple logistic regression (LR) methodology was used to develop an LR model for predicting successful postpyloric nasoenteric tube placement. The area under the receiver operating characteristic curve (AUC) was used to evaluate the performance of these models. Successful postpyloric nasoenteric tube placement was confirmed in 427 of 939 patients enrolled. For predicting successful postpyloric nasoenteric tube placement, the performance of the 3 decision trees was similar in terms of the AUCs: 0.715 for the CHAID model, 0.682 for the SimpleCart model, and 0.671 for the J48 model. The AUC of the LR model was 0.729, which outperformed the J48 model. Both the CHAID and LR models achieved an acceptable discrimination for predicting successful postpyloric nasoenteric tube placement and were useful for intensivists in the setting of self-propelled spiral nasoenteric tube insertion. © 2016 American Society for Parenteral and Enteral Nutrition.

  20. Fracture Toughness Round Robin Test International in pressure tube materials

    International Nuclear Information System (INIS)

    Villagarcia, M.P.; Liendo, M.F.

    1993-01-01

    Part of the pressure tubes surveillance program of CANDU type reactors is to determine the fracture toughness using a special fracture specimen and test procedure. Atomic Energy of Canada Limited decided to hold a Round Robin Test International and 9 laboratories participated worldwide in which several pressure tube materials were selected: Zircaloy-2, Zr-2.5%Nb cold worked and Zr-2.5%Nb heat treated. The small specimens used held back the thickness and curvature of the tube. J-R curves at room temperature were obtained and the crack extension values were determined by electrical potential drop techniques. These values were compared with results generated from other laboratories and a bid scatter was founded. It could be due to slight variations in the test method or inhomogeneity of the materials and a statistical study must be done to see if there is any pattern. The next step for the Round Robin Test would be to make some modifications in the test method in order to reduce the scatter. (Author)

  1. Solar updraft power generator with radial and curved vanes

    Science.gov (United States)

    Hafizh, Hadyan; Hamsan, Raziff; Zamri, Aidil Azlan Ahmad; Keprawi, Mohamad Fairuz Mohamad; Shirato, Hiromichi

    2018-02-01

    Solar radiation is the largest source of energy available on earth and the solar updraft power generator (SUPG) is a renewable energy facility capable of harnessing its abundant power. Unlike the conventional wind turbines that harness natural wind in the atmosphere and often encounter with the intermittent issue or even complete cut-off from airflow, the SUPG creates artificial wind as a result of solar-induced convective flows. However, the SUPG has an inherent low total efficiency due to the conversion of thermal energy into pressure energy. Acknowledging the low efficiency and considering its potential as a renewable energy facility, the current work aims to increase the total efficiency by installing a series of guide walls inside the collector. Two types of guide walls were used i.e. radial and curved vanes. The result with curved vanes showed that the updraft velocity is higher compare to those without vanes. About 18% and 64% improvement of updraft velocity and mechanical power were attained respectively. Furthermore, it was observed that the role of radial vanes configuration was more to produce a smooth updraft velocity profile rather than increasing the total efficiency.

  2. Sensitive technique for detecting outer defect on tube with remote field eddy current testing

    International Nuclear Information System (INIS)

    Kobayashi, Noriyasu; Nagai, Satoshi; Ochiai, Makoto; Jimbo, Noboru; Komai, Masafumi

    2008-01-01

    In the remote field eddy current testing, we proposed the method of enhancing the magnetic flux density in the vicinity of an exciter coil by controlling the magnetic flux direction for increasing the sensitivity of detecting outer defects on a tube and used the flux guide made of a magnetic material for the method. The optimum structural shape of the flux guide was designed by the magnetic field analysis. On the experiment with the application of the flux guide, the magnetic flux density increased by 59% and the artificial defect detection signal became clear. We confirmed the proposed method was effective in a high sensitivity. (author)

  3. Ultrasound-guided genitourinary interventions: principles and techniques

    Directory of Open Access Journals (Sweden)

    Byung Kwan Park

    2017-10-01

    Full Text Available Ultrasound (US is often used to guide various interventional procedures in the genitourinary (GU tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  4. Ultrasound-guided genitourinary interventions: principles and techniques

    Energy Technology Data Exchange (ETDEWEB)

    Park, Byung Kwan [Dept. of Radiology, Samsung Medical Center, Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of)

    2017-10-15

    Ultrasound (US) is often used to guide various interventional procedures in the genitourinary (GU) tract because it can provide real-time imaging without any radiation hazard. Moreover, US can clearly visualize the pathway of an aspiration or biopsy needle to ensure the safety of the intervention. US guidance also helps clinicians to access lesions via the transabdominal, transhepatic, transvaginal, transrectal, and transperineal routes. Hence, US-guided procedures are useful for radiologists who wish to perform GU interventions. However, US-guided procedures and interventions are difficult for beginners because they involve a steep initial learning curve. The purpose of this review is to describe the basic principles and techniques of US-guided GU interventions.

  5. Measure of the attenuation curve of a beam of X-rays with TLD-100 dosimeters of LiF

    International Nuclear Information System (INIS)

    Bonzi, E. V.; Mainardi, R. T.; Germanier, A.; Delgado, V.

    2011-10-01

    The attenuation curve of a beam of X-rays represents the beam intensity in function of the attenuator thickness interposed between the source and the detector. To know with the major possible precision the attenuation curve is indispensable in procedures of spectral reconstruction. Their periodic measuring also offers valuable information on the correct operation of a tube of X-rays, diagnostic or therapy, when not have a specific detector for that activity. In this work was measured the attenuation curve of a tube of X-rays operated to 50 kV and 0.5 ma, using existent elements in any diagnostic or therapy laboratory with radiations. In the measures commercial aluminum foil was used, bent until 24 times and thermoluminescent dosimeters TLD 100 - LiF. Also, for comparison, was measured this attenuation curve with an ionization chamber brand Capintec model 192. Was determined by X-rays fluorescence the composition of the aluminium foil, since the present elements in the alloy can to affect the form of the attenuation curve. It is interesting to observe that these elements are in very low proportion (ppm) that they do not alter the attenuation capacity of the pure aluminium. Finally in a precision balance we weigh a big piece (30 cm x 100 cm) of aluminium foil and we obtained the thickness in g/c m2. It is possible to obtain attenuation curves of a beam of X-rays, with a high precision procedure and reproducibility. The use of TLD-100 dosimeters of LiF or similar makes that this activity was also quick and simple. (Author)

  6. Evaluation of sampling plans for in-service inspection of steam generator tubes

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Baird, D.B.

    1994-02-01

    This report summarizes the results of three previous studies to evaluate and compare the effectiveness of sampling plans for steam generator tube inspections. An analytical evaluation and Monte Carlo simulation techniques were the methods used to evaluate sampling plan performance. To test the performance of candidate sampling plans under a variety of conditions, ranges of inspection system reliability were considered along with different distributions of tube degradation. Results from the eddy current reliability studies performed with the retired-from-service Surry 2A steam generator were utilized to guide the selection of appropriate probability of detection and flaw sizing models for use in the analysis. Different distributions of tube degradation were selected to span the range of conditions that might exist in operating steam generators. The principal means of evaluating sampling performance was to determine the effectiveness of the sampling plan for detecting and plugging defective tubes. A summary of key results from the eddy current reliability studies is presented. The analytical and Monte Carlo simulation analyses are discussed along with a synopsis of key results and conclusions

  7. Design of airborne imaging spectrometer based on curved prism

    Science.gov (United States)

    Nie, Yunfeng; Xiangli, Bin; Zhou, Jinsong; Wei, Xiaoxiao

    2011-11-01

    A novel moderate-resolution imaging spectrometer spreading from visible wavelength to near infrared wavelength range with a spectral resolution of 10 nm, which combines curved prisms with the Offner configuration, is introduced. Compared to conventional imaging spectrometers based on dispersive prism or diffractive grating, this design possesses characteristics of small size, compact structure, low mass as well as little spectral line curve (smile) and spectral band curve (keystone or frown). Besides, the usage of compound curved prisms with two or more different materials can greatly reduce the nonlinearity inevitably brought by prismatic dispersion. The utilization ratio of light radiation is much higher than imaging spectrometer of the same type based on combination of diffractive grating and concentric optics. In this paper, the Seidel aberration theory of curved prism and the optical principles of Offner configuration are illuminated firstly. Then the optical design layout of the spectrometer is presented, and the performance evaluation of this design, including spot diagram and MTF, is analyzed. To step further, several types of telescope matching this system are provided. This work provides an innovational perspective upon optical system design of airborne spectral imagers; therefore, it can offer theoretic guide for imaging spectrometer of the same kind.

  8. Tube holding system

    International Nuclear Information System (INIS)

    Cunningham, R.C.

    1978-01-01

    A tube holding rig is described for the lateral support of tubes arranged in tight parcels in a heat exchanger. This tube holding rig includes not less than two tube supporting assemblies, with a space between them, located crosswise with respect to the tubes, each supporting assembly comprising a first set of parallel components in contact with the tubes, whilst a second set of components is also in contact with the tubes. These two sets of parts together define apertures through which the tubes pass [fr

  9. HF electronic tubes. Technologies, grid tubes and klystrons

    International Nuclear Information System (INIS)

    Lemoine, Th.

    2009-01-01

    This article gives an overview of the basic technologies of electronic tubes: cathodes, electronic optics, vacuum and high voltage. Then the grid tubes, klystrons and inductive output tubes (IOT) are introduced. Content: 1 - context and classification; 2 - electronic tube technologies: cathodes, electronic optics, magnetic confinement (linear tubes), periodic permanent magnet (PPM) focussing, collectors, depressed collectors; 3 - vacuum technologies: vacuum quality, surface effects and interaction with electrostatic and RF fields, secondary emission, multipactor effect, thermo-electronic emission; 4 - grid tubes: operation of a triode, tetrodes, dynamic operation and classes of use, 'common grid' and 'common cathode' operation, ranges of utilisation and limitations, operation of a tetrode on unadjusted load, lifetime of a tetrode, uses of grid tubes; 5 - klystrons: operation, impact of space charge, multi-cavity klystrons, interaction efficiency, extended interaction klystrons, relation between interaction efficiency, perveance and efficiency, ranges of utilization and power limitations, multi-beam klystrons and sheet beam klystrons, operation on unadjusted load, klystron band pass and lifetime, uses; 6 - IOT: principle of operation, ranges of utilisation and limitations, interaction efficiency and depressed collector IOT, IOT lifetime and uses. (J.S.)

  10. Numerical calculation for flow field of servo-tube guided hydraulic control rod driving system

    International Nuclear Information System (INIS)

    He Keyu; Han Weishi

    2010-01-01

    A new-style hydraulic control rod driving mechanism was put forward by using servo-tube control elements for the design of control rod driving mechanism. The results of numerical simulation by CFD program Fluent for flow field of hydraulic driving cylinder indicate that the bigger the outer diameter of servo-tube, the smaller the resistance coefficient of variable throttle orifice. The zero position gap of variable throttle orifice could be determined on 0.2 mm in the design. The pressure difference between the upper and nether surfaces of piston was mainly created by the throttle function of fixed throttle orifice. It can be effectively controlled by changing the gap of variable throttle orifice. And the lift force of driving cylinder is able to meet the requirement on the design load. (authors)

  11. Guide for preparing annual reports on radiation-safety testing of electronic products (general)

    International Nuclear Information System (INIS)

    1987-10-01

    For manufacturers of electronic products other than those for which a specific guide has been issued, the guide replaces the Guide for the Filing of Annual Reports (21 CFR Subchapter J, Section 1002.11), HHS Publication FDA 82-8127. The electronic product (general) annual reporting guide is applicable to the following products: products intended to produce x radiation (accelerators, analytical devices, therapy x-ray machines); microwave diathermy machines; cold-cathode discharge tubes; and vacuum switches and tubes operating at or above 15,000 volts. To carry out its responsibilities under Public Law 90-602, the Food and Drug Administration's Center for Devices and Radiological Health (CDRH) has issued a series of regulations contained in Title 21 of the Code of Federal Regulations (CFR). Part 1002 of 21 CFR deals with records and reports. Section 1002.61 categorizes electronic products into Groups A through C. Section 1002.30 requires manufacturers of products in Groups B and C to establish and maintain certain records, while Section 1002.11 requires such manufacturers to submit an Annual Report summarizing the contents of the required records. Section 1002.7 requires that reports conform to reporting guides issued by CDRH unless an acceptable justification for an alternate format is provided

  12. Friction stir welding of F/M ODS steel plug and F/M steel tube

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Suk Hoon, E-mail: shkang77@kaeri.re.kr [Nuclear Materials Division, Korea Atomic Energy Research Institute (Korea, Republic of); Vasudevan, M. [Materials Technology Division, Indira Gandhi Centre for Atomic Research, Kalpakkam (India); Noh, Sanghoon; Jin, Hyun Ju; Jang, Jinsung; Kim, Tae Kyu [Nuclear Materials Division, Korea Atomic Energy Research Institute (Korea, Republic of)

    2016-11-01

    Highlights: • Friction stir welding (FSW) was used for joining of oxide dispersion strengthened (ODS) steel plug and F/M steel tube. • The curvature and smaller thickness of tube was the major limitation for applying FSW method, it was solved using specially designed jig. • Considerable hardening occurs in the joint because the cooling rate was sufficient to reproduce a martensitic microstructure. • The measured hoop strength of the FSWed joint was 70–90 MPa, the value was at around 70% of the tube. - Abstract: Friction stir welding (FSW) was used for joining of oxide dispersion strengthened (ODS) steel plug and F/M steel tube. The dimensions of the tube included outer diameter of 7 mm, wall thickness of 0.5 mm. The objective was to find suitable process variables for gaining enough frictional heat from those thin and curved pieces. A specially designed jig was used for stabilization and slow rotation of tube during FSW. Additionally, the plug was designed to overlap the tube. Inconel 718 was used as FSW tool, the diameter was 3.5 mm. The adequate rotation speed of the tool and jig were 1200 rpm and 1.5 rpm, respectively. The joining was successfully accomplished using above combination, showing a good possibility. The hoop stress tests of joint were conducted by blowing Ar gas into the tube, the flow rate of gas was 10 MPa/min. The measured hoop stress was 70–90 MPa, the value was at around 70% of the tube.

  13. Friction stir welding of F/M ODS steel plug and F/M steel tube

    International Nuclear Information System (INIS)

    Kang, Suk Hoon; Vasudevan, M.; Noh, Sanghoon; Jin, Hyun Ju; Jang, Jinsung; Kim, Tae Kyu

    2016-01-01

    Highlights: • Friction stir welding (FSW) was used for joining of oxide dispersion strengthened (ODS) steel plug and F/M steel tube. • The curvature and smaller thickness of tube was the major limitation for applying FSW method, it was solved using specially designed jig. • Considerable hardening occurs in the joint because the cooling rate was sufficient to reproduce a martensitic microstructure. • The measured hoop strength of the FSWed joint was 70–90 MPa, the value was at around 70% of the tube. - Abstract: Friction stir welding (FSW) was used for joining of oxide dispersion strengthened (ODS) steel plug and F/M steel tube. The dimensions of the tube included outer diameter of 7 mm, wall thickness of 0.5 mm. The objective was to find suitable process variables for gaining enough frictional heat from those thin and curved pieces. A specially designed jig was used for stabilization and slow rotation of tube during FSW. Additionally, the plug was designed to overlap the tube. Inconel 718 was used as FSW tool, the diameter was 3.5 mm. The adequate rotation speed of the tool and jig were 1200 rpm and 1.5 rpm, respectively. The joining was successfully accomplished using above combination, showing a good possibility. The hoop stress tests of joint were conducted by blowing Ar gas into the tube, the flow rate of gas was 10 MPa/min. The measured hoop stress was 70–90 MPa, the value was at around 70% of the tube.

  14. Equilibrium depth of scour at straight guide banks

    Science.gov (United States)

    Gjunsburgs, B.; Bulankina, V.

    2017-10-01

    The equilibrium stage of scour at the head of straight guide banks with a uniform and stratified bed conditions have been studied. The contraction of the river by bridge crossing with straight guide banks considerably alters the flow pattern. The streamlines become curve and the concentration of streamlines, longitudinal and transverse slopes of the water surface, a local increase in velocity, vortex and eddy structures, and the origin of a flow separation zone between the extreme streamlines and the guide bank are observed and local scour is developing at the head of the straight guide banks. New formulae for calculation of equilibrium depth of scour at straight guide banks at uniform and stratified river bed is elaborated and confirmed by tests and computer modelling results.

  15. Apparatus for unloading more particularly for nuclear fuel pellets, and to fill tubes with these pellets

    International Nuclear Information System (INIS)

    Fort, C.; Masson, S.

    1985-01-01

    The device allows to discharge the nuclear fuel pellets arranged in trays, and to introduce them to form stacks of pellets of determined length in storage tubes of associated diameter. It comprises a carriage to make the pellets slip from each tray on a guide vibrating bowl to a shute and then on a conveyor which loads the pellets into an intermediate tube to form a stack of the said length. A lift moves the intermediate tube transversally to its length between a loading position and a transfer position. Means allow to move a storage tube bundle to put each tube in its turn face to the transfer position. The stack of pellets contained in the intermediate tube which is in the transfer position is thus sent back to the storage tube facing it. The invention applies to pellets which have been sintered in the trays in inert atmosphere. These pellets have to be stored before several examinations and grinding, and finally loading into the cans to constitute fuel rods. These sintered pellets have a cylindrical shape and the invention spares them hard handling which would damage them [fr

  16. Properties of an irradiated heat-treated Zr-2.5Nb pressure tube removed from the NPD reactor

    Energy Technology Data Exchange (ETDEWEB)

    Chow, C.K. [Atomic Energy of Canada Limited, Pinawa, Manitoba (Canada); Coleman, C.E. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Koike, M.H. [Power Reactor and Nuclear Fuel Development Corp., O-Arai Engineering Centre, O-Arai (Japan); Causey, A.R.; Ells, C.E.; Hosbons, R.R.; Sagat, S.; Urbanic, V.F.; Rodgers, D.K

    1997-07-01

    Some pressure tubes in reactors moderated by heavy water have been made from heat-treated (HT) Zr-2.5Nb. One such tube was removed from the NPD nuclear reactor after 20 years of operation. An extensive program was carried out jointly by AECL and PNC to evaluate the condition and properties of this pressure tube. The investigations include irradiation creep, tensile, corrosion, delayed hydride cracking (DHC), fatigue, and fracture properties. Results show that: (I) the in-reactor elongation rate is much lower and the transverse strain rates are slightly larger than in cold-worked (CW) Zr-2.5Nb tubes; (2) the tensile properties, hydrogen pickup, threshold stress intensity factor for DHC initiation, DHC velocity, and fatigue crack growth rates were similar to those of the CW Zr-2.5Nb material; (3) the fracture toughness of this tube, as measured by curved compact toughness specimens and burst tests, is slightly higher than the CW tubes. The results were also compared with other heat-treated Zr-2.5Nb materials irradiated in the Fugen reactor. The tube was in excellent condition when removed from the reactor and would have been satisfactory for further service. (author)

  17. Tube to tube excursive instability - sensitivities and transients

    International Nuclear Information System (INIS)

    Brown, M.; Layland, M.W.

    1980-01-01

    A simple basic analysis of excursive instability in a boiler tube shows how it depends upon operating conditions and physical properties. A detailed mathematical model of an AGR boiler is used to conduct a steady state parameter sensitivity survey. It is possible from this basis to anticipate the effects of changes in operating conditions and changes in design parameters upon tube to tube stability. Dynamic responses of tubes operating near the stability threshold are examined using a mathematical model. Simulated excursions are triggered by imparting small abrupt pressure changes on the boiler inlet pressure. The influences of the magnitude of the pressure change, waterside friction factor and gas side coupling between tubes are examined. (author)

  18. Tube-support response to tube-denting evaluation. Volume 1. Final report

    International Nuclear Information System (INIS)

    Anderson, P.L.; Hall, J.F.; Shah, P.K.; Wills, R.L.

    1983-05-01

    The response of the tube supports is one of the important considerations of tube denting in a steam generator. Investigations have indicated that damaged tube supports have the potential to distort and damage tubes. This investigation considers the response to tube denting of the Combustion Engineering type tube supports. Drilled support plates and eggcrate tube supports are tested in a model steam generator in which tube denting is induced. The experimental data is used to verify and refine analytical predictor models developed using finite element techniques. It was found that analytical models underpredicted the deformations of the tube supports and appropriate modifications to enhance the predictive capability are identified. Non-destructive examination methods are evaluated for application to operating steam generators. It was found that the standard eddy current and profilometry techniques are acceptable methods for determining tube deformations, but these techniques are not adequate to assess tube support damage. Radiography is judged to be the best available means of determining the extent and progression of damage in tube supports

  19. Lagrangian Curves on Spectral Curves of Monopoles

    International Nuclear Information System (INIS)

    Guilfoyle, Brendan; Khalid, Madeeha; Ramon Mari, Jose J.

    2010-01-01

    We study Lagrangian points on smooth holomorphic curves in TP 1 equipped with a natural neutral Kaehler structure, and prove that they must form real curves. By virtue of the identification of TP 1 with the space LE 3 of oriented affine lines in Euclidean 3-space, these Lagrangian curves give rise to ruled surfaces in E 3 , which we prove have zero Gauss curvature. Each ruled surface is shown to be the tangent lines to a curve in E 3 , called the edge of regression of the ruled surface. We give an alternative characterization of these curves as the points in E 3 where the number of oriented lines in the complex curve Σ that pass through the point is less than the degree of Σ. We then apply these results to the spectral curves of certain monopoles and construct the ruled surfaces and edges of regression generated by the Lagrangian curves.

  20. Condenser tube buckling within tube-tubesheet joints

    International Nuclear Information System (INIS)

    Willertz, L.E.; Kalnins, A.; Updike, D.P.

    1991-01-01

    The problem of the appearance of protrusions, or bumps, in the interior of roller-expanded tubes within a tubesheet is addressed. Such bumps have been observed in condensers of power plants. A brief history of the reported occurrences of the bumps is given. The hypothesis is advanced that the mechanics of the formation of the bumps is similar to a buckling problem that has 'bifurcation at infinity'. Following this hypothesis, a two-dimensional physical model is developed, and the application of this model to study a three-dimensional bump is proposed. It is proposed in this paper that an initial deviation from the circular shape of the tube required to produce a bump. It is shown that without such a deviation the tubes cannot buckle. An experiment with short tube segments has been performed that verifies some of the features of the observed condenser tube bumps. Exactly what force produced the initial deviation for the observed bumps is still unknown. Available evidence implicates the hydro-laser jet that is used in the cleaning of tubes and tubesheets. A scenario of how a bump could have been produced by the hydro-laser jet is proposed. (author)

  1. Effects of curved midline and varying width on the description of the effective diffusivity of Brownian particles

    Science.gov (United States)

    Chávez, Yoshua; Chacón-Acosta, Guillermo; Dagdug, Leonardo

    2018-05-01

    Axial diffusion in channels and tubes of smoothly-varying geometry can be approximately described as one-dimensional diffusion in the entropy potential with a position-dependent effective diffusion coefficient, by means of the modified Fick–Jacobs equation. In this work, we derive analytical expressions for the position-dependent effective diffusivity for two-dimensional asymmetric varying-width channels, and for three-dimensional curved midline tubes, formed by straight walls. To this end, we use a recently developed theoretical framework using the Frenet–Serret moving frame as the coordinate system (2016 J. Chem. Phys. 145 074105). For narrow tubes and channels, an effective one-dimensional description reducing the diffusion equation to a Fick–Jacobs-like equation in general coordinates is used. From this last equation, one can calculate the effective diffusion coefficient applying Neumann boundary conditions.

  2. Steam Generator tube integrity -- US Nuclear Regulatory Commission perspective

    International Nuclear Information System (INIS)

    Murphy, E.L.; Sullivan, E.J.

    1997-01-01

    In the US, the current regulatory framework was developed in the 1970s when general wall thinning was the dominant degradation mechanism; and, as a result of changes in the forms of degradation being observed and improvements in inspection and tube repair technology, the regulatory framework needs to be updated. Operating experience indicates that the current U.S. requirements should be more stringent in some areas, while in other areas they are overly conservative. To date, this situation has been dealt with on a plant-specific basis in the US. However, the NRC staff is now developing a proposed steam generator rule as a generic framework for ensuring that the steam generator tubes are capable of performing their intended safety functions. This paper discusses the current U.S. regulatory framework for assuring steam generator (SG) tube integrity, the need to update this regulatory framework, the objectives of the new proposed rule, the US Nuclear Regulatory Commission (NRC) regulatory guide (RG) that will accompany the rule, how risk considerations affect the development of the new rule, and some outstanding issues relating to the rule that the NRC is still dealing with

  3. The Fast Intelligent Tracking (F!T) tube: A CRT without a shadow mask

    NARCIS (Netherlands)

    Bergman, A.H.; Brink, van den H.B.; Budzelaar, F.P.M.; Engelaar, P.J.; Holtslag, A.H.M.; IJzerman, W.L.; Krijn, M.P.C.M.; Lieshout, van P.J.G.; Notari, A.; Willemsen, O.H.

    2003-01-01

    The F!T tube is a new type of CRT without a shadow mask. The primary function of the mask, color selection, is taken over by an electronic control system that guides the electron beams over the correct phosphor lines. The position of the beams is detected by means of dedicated structures on the

  4. Cone-Beam Computed Tomography-Guided Percutaneous Radiologic Gastrostomy

    International Nuclear Information System (INIS)

    Moehlenbruch, Markus; Nelles, Michael; Thomas, Daniel; Willinek, Winfried; Gerstner, Andreas; Schild, Hans H.; Wilhelm, Kai

    2010-01-01

    The purpose of this study was to investigate the feasibility of a flat-detector C-arm-guided radiographic technique (cone-beam computed tomography [CBCT]) for percutaneous radiologic gastrostomy (PRG) insertion. Eighteen patients (13 men and 5 women; mean age 62 years) in whom percutaneous endoscopic gastrostomy (PEG) had failed underwent CBCT-guided PRG insertion. PEG failure or unsuitability was caused by upper gastrointestinal tract obstruction in all cases. Indications for gastrostomy were esophageal and head and neck malignancies, respectively. Before the PRG procedure, initial C-arm CBCT scans were acquired. Three- and 2-dimensional soft-tissue reconstructions of the epigastrium region were generated on a dedicated workstation. Subsequently, gastropexy was performed with T-fasteners after CBCT-guided puncture of the stomach bubble, followed by insertion of an 14F balloon-retained catheter through a peel-away introducer. Puncture of the stomach bubble and PRG insertion was technically successful in all patients without alteration of the epigastric region. There was no malpositioning of the tube or other major periprocedural complications. In 2 patients, minor complications occurred during the first 30 days of follow-up (PRG malfunction: n = 1; slight infection: n = 1). Late complications, which were mainly tube disturbances, were observed in 2 patients. The mean follow-up time was 212 days. CBCT-guided PRG is a safe, well-tolerated, and successful method of gastrostomy insertion in patients in whom endoscopic gastrostomy is not feasible. CBCT provides detailed imaging of the soft tissue and surrounding structures of the epigastric region in one diagnostic tour and thus significantly improves the planning of PRG procedures.

  5. Using an indwelled test tube as a good "navigator" during enterostomy closure.

    Science.gov (United States)

    Hirose, Ryuichiro; Tojigamori, Manabu; Obata, Satoshi; Tatsuta, Kyosuke; Kawakubo, Naonori; Arima, Toru

    2012-11-01

    Surgeons often have difficulty in identifying a suitable incision line to enter the peritoneal cavity for stoma mobilization during enterostomy closure. A mini-size test tube that is preoperatively placed into the stoma can act as an efficient guide in finding a free area to enter the peritoneal cavity, by supplying efficient counter traction and a palpable marker of the intestinal wall.

  6. Male-female crosstalk during pollen germination, tube growth and guidance, and double fertilization.

    Science.gov (United States)

    Dresselhaus, Thomas; Franklin-Tong, Noni

    2013-07-01

    Sperm cells of flowering plants are non-motile and thus require transportation to the egg apparatus via the pollen tube to execute double fertilization. During its journey, the pollen tube interacts with various sporophytic cell types that support its growth and guide it towards the surface of the ovule. The final steps of tube guidance and sperm delivery are controlled by the cells of the female gametophyte. During fertilization, cell-cell communication events take place to achieve and maximize reproductive success. Additional layers of crosstalk exist, including self-recognition and specialized processes to prevent self-fertilization and consequent inbreeding. In this review, we focus on intercellular communication between the pollen grain/pollen tube including the sperm cells with the various sporophytic maternal tissues and the cells of the female gametophyte. Polymorphic-secreted peptides and small proteins, especially those belonging to various subclasses of small cysteine-rich proteins (CRPs), reactive oxygen species (ROS)/NO signaling, and the second messenger Ca(2+), play center stage in most of these processes.

  7. A multi-modular helical magnetic millirobot navigating in curved tubular environments

    Directory of Open Access Journals (Sweden)

    Seungmun Jeon

    2017-05-01

    Full Text Available This paper proposes a novel multi-modular helical magnetic millirobot (MHMM able to navigate in curved tubular environments. The proposed MHMM is basically composed of head, middle, and tail modules serially connected by a universal joint, and can employ more modules if necessary. The head module is a helical body with a magnetic rotary tip attached to the front end. Thus, once located in a curved tube filled with a fluid, the MHMM can effectively generate navigating or unclogging motions simply actuated by an external rotating magnetic field. This paper also examines the dynamic characteristics of the MHMM under various working conditions to manipulate the MHMM in a stable and safe manner. Then, it demonstrates various controlled motions of the MHMM in an in-vitro pulsatile flow environment to show the validity of the proposed structure and method.

  8. Elliptic Tales Curves, Counting, and Number Theory

    CERN Document Server

    Ash, Avner

    2012-01-01

    Elliptic Tales describes the latest developments in number theory by looking at one of the most exciting unsolved problems in contemporary mathematics--the Birch and Swinnerton-Dyer Conjecture. The Clay Mathematics Institute is offering a prize of 1 million to anyone who can discover a general solution to the problem. In this book, Avner Ash and Robert Gross guide readers through the mathematics they need to understand this captivating problem. The key to the conjecture lies in elliptic curves, which are cubic equations in two variables. These equations may appear simple, yet they arise from

  9. Core design of super LWR with double tube water rods

    International Nuclear Information System (INIS)

    Wu, Jianhui; Oka, Yoshiaki

    2014-01-01

    Highlights: • Supercritical light water cooled and moderated reactor with double tube water rods is developed. • Double-row fuel rod assembly and out-in fuel loading pattern are applied. • Separation plates in peripheral assemblies increase average outlet temperature. • Neutronic and thermal design criteria are satisfied during the cycle. - Abstract: Double tube water rods are employed in core design of super LWR to simplify the upper core structure and refueling procedure. The light water moderator flows up in the inner tube from the bottom of the core, then, changes the flow direction at the top of the core into the outer tube and flows out at the bottom of the core. It eliminates the moderator guide/distribution tubes into the single tube water rods from the top dome of the reactor pressure vessel of the previous super LWR design. Two rows of fuel rods are filled between the water rods in the fuel assembly. Out-in refueling pattern is adopted to flatten radial power distribution. The peripheral fuel assemblies of the core are divided into four flow zones by separation plates for increasing the average core outlet temperature. Three enrichment zones are used for axial power flattening. The equilibrium core is analyzed based on neutronic/thermal-hydraulic coupled model. The results show that, by applying the separation plates in peripheral fuel assemblies and low gadolinia enrichment, the maximum cladding surface temperature (MCST) is limited to 653 °C with the average outlet temperature of 500 °C. The inherent safety is satisfied by the negative void reactivity effects and sufficient shutdown margin

  10. Transfer of a cold atmospheric pressure plasma jet through a long flexible plastic tube

    International Nuclear Information System (INIS)

    Kostov, Konstantin G; Prysiazhnyi, Vadym; Honda, Roberto Y; Machida, Munemasa

    2015-01-01

    This work proposes an experimental configuration for the generation of a cold atmospheric pressure plasma jet at the downstream end of a long flexible plastic tube. The device consists of a cylindrical dielectric chamber where an insulated metal rod that serves as high-voltage electrode is inserted. The chamber is connected to a long (up to 4 m) commercial flexible plastic tube, equipped with a thin floating Cu wire. The wire penetrates a few mm inside the discharge chamber, passes freely (with no special support) along the plastic tube and terminates a few millimeters before the tube end. The system is flushed with Ar and the dielectric barrier discharge (DBD) is ignited inside the dielectric chamber by a low frequency ac power supply. The gas flow is guided by the plastic tube while the metal wire, when in contact with the plasma inside the DBD reactor, acquires plasma potential. There is no discharge inside the plastic tube, however an Ar plasma jet can be extracted from the downstream tube end. The jet obtained by this method is cold enough to be put in direct contact with human skin without an electric shock. Therefore, by using this approach an Ar plasma jet can be generated at the tip of a long plastic tube far from the high-voltage discharge region, which provides the safe operation conditions and device flexibility required for medical treatment. (paper)

  11. Feasibility of intermittent pneumatic compression for venous thromboembolism prophylaxis during magnetic resonance imaging-guided interventions

    Energy Technology Data Exchange (ETDEWEB)

    Maybody, Majid, E-mail: maybodym@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Taslakian, Bedros, E-mail: bt05@aub.edu.lb [Department of Diagnostic Radiology, American University of Beirut Medical Center, Riad El-Solh, 1107 2020 Beirut (Lebanon); Durack, Jeremy C., E-mail: durackj@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Kaye, Elena A., E-mail: kayee@mskcc.org [Department of Medical Physics, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Erinjeri, Joseph P., E-mail: erinjerj@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Srimathveeravalli, Govindarajan, E-mail: srimaths@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States); Solomon, Stephen B., E-mail: solomons@mskcc.org [Department of Radiology, Memorial Sloan Kettering Cancer Center, 1275 York Avenue, New York, NY 10065 (United States)

    2015-04-15

    Highlights: •The controller of a standard SCD is labeled as an “MR-unsafe”. •No commercially available “MR-safe” SCDs. •Standard SCDs can be used in iMRI by placing the device outside the MRI scanner room. •Using serial extension tubing did not cause device failure. -- Abstract: Purpose: Venous thromboembolism (VTE) is a common cause of morbidity and mortality in hospitalized and surgical patients. To reduce risk, perioperative VTE prophylaxis is recommended for cancer patients undergoing surgical or interventional procedures. Magnetic resonance imaging (MRI) is increasingly used in interventional oncology when alternative imaging modalities do not adequately delineate malignancies. Extended periods of immobilization during MRI-guided interventions necessitate an MR compatible sequential compression device (SCD) for intra-procedural mechanical VTE prophylaxis. Such devices are not commercially available. Materials and methods: A standard SCD routinely used at our institution for VTE prophylaxis during interventional procedures was used. To satisfy MR safety requirements, the SCD controller was placed in the MR control room and connected to the compression sleeves in the magnet room through the wave guide using tubing extensions. The controller pressure sensor was used to monitor adequate pressure delivery and detect ineffective low or abnormal high pressure delivery. VTE prophylaxis was provided using the above mentioned device for 38 patients undergoing MR-guided ablations. Results: There was no evidence of device failure due to loss of pressure in the extension tubing assembly. No interference with the anesthesia or interventional procedures was documented. Conclusion: Although the controller of a standard SCD is labeled as “MR-unsafe”, the SCD can be used in interventional MR settings by placing the device outside the MR scanner room. Using serial tubing extensions did not cause device failure. The described method can be used to provide

  12. High negative pressure subcutaneous suction drain for managing debilitating subcutaneous emphysema secondary to tube thoracostomy for an iatrogenic post computed tomography guided transthoracic needle biopsy pneumothorax: Case report and review of literature.

    Science.gov (United States)

    Ahmed, Zeeshan; Patel, Pinakin; Singh, Suresh; Sharma, Raj Govind; Somani, Pankaj; Gouri, Abdul Rauf; Singh, Shiv

    2016-01-01

    Subcutaneous emphysema is a common complication of tube thoracostomy. Though self-limiting, it should be treated when it causes palpebral closure, dyspnea, dysphagia or undue disfigurement resulting in anxiety and distress to the patient. A 72year old man who was a known case of COPD on bronchodilators developed a large pneumothorax and respiratory distress after a CT guided transthoracic lung biopsy done for a lung opacity (approx. 3×3cm) at the right hilar region on Chest X-ray. Within 24h of an urgent tube thoracostomy, patient developed intractable subcutaneous emphysema with closure of palpebral fissure and dyspnea unresponsive to increasing suction on chest tube. A subcutaneous fenestrated drain was placed mid-way between the nipple and clavicle in the mid-clavicular line bilaterally. Continuous negative suction (-150mmHg) resulted in immediate, sustained relief and complete resolution within 5days. Extensive and debilitating SE (subcutaneous emphysema) has to be treated promptly to relieve patient discomfort, dysphagia or imminent respiratory compromise. A variety of treatment have been tried including infraclavicular blow-hole incisions, subcutaneous drains +/- negative pressure suction, fenestrated angiocatheters, Vacuum assisted dressings and increasing suction on a pre-existing chest tube. We describe a high negative pressure subcutaneous suction drain which provides immediate and sustained relief in debilitating SE. Debilitating subcutaneous emphysema which causes distress, anxiety, palpebral closure, dyspnoea or dysphagia requires intervention. High negative pressure subcutaneous suction drain provides immediate and sustained relief in extensive and debilitating SE. Copyright © 2016 The Authors. Published by Elsevier Ltd.. All rights reserved.

  13. Guiding Properties of Silica/Air Hollow-Core Bragg Fibers

    DEFF Research Database (Denmark)

    Foroni, Matteo; Passaro, Davide; Poli, Federica

    2008-01-01

    The guiding properties of realistic silica/air hollow-core Bragg fibers have been investigated by calculating the dispersion curves, the confinement loss spectrum and the field distribution of the guided modes through a full-vector modal solver based on the finite element method. In particular, t...... the different possible applications, the feasibility of a DNA bio-sensor based on a hollow-core Bragg fiber has been demonstrated....

  14. Magneto-transport studies on curved two-dimensional electron gases in InGaAs-microscrolls

    International Nuclear Information System (INIS)

    Schumacher, O.

    2007-01-01

    In this thesis magneto-resistance studies on evenly curved two-dimensional electron systems in cylindric geometry are presented and discussed. A principle first introduced by Prinz and co-workers in 1998 enables us to roll up thin semiconductor layer systems by taking advantage of internal elastic strain. The radius of such a semiconductor tube can be adjusted ranging from a few nanometers up to several micrometers. The tubes' shape and place on the substrate can be defined by lithographic methods which are presented in this work. Furthermore, we show rolled-up structures containing a two-dimensional electron system in the tube wall. With a special lithographic procedure we are able to structure, to contact and to roll up these 2D-electron-gases in Hall geometry. As a result, a cylindric two-dimensional electron system is produced, which experiences a modulation of the perpendicular magnetic field component. The radius of curvature of our structures is about 10 μm, the carrier mobility is optimized to values up to 125,000 cm 2 /Vs. In transport experiments on curved Hall bars containing two dimensional electron systems two Hall bar orientations, with respect to the curvature, may be distinguished. In this work both orientations, i.e. with a Hall bar along the tube curvature as well as a Hall bar along the tube axis, are presented and discussed. Measurements on Hall bars along the curvature show signatures in the longitudinal resistance, which can be understood with the help of the Landauer-Buettiker-formalism and the model of magnetic barriers. For Hall bars oriented along the tube axis the perpendicular magnetic field component averaged over the width of the bar defines the minimum position of the Shubnikov-de Haas-oscillations as well as the slope of the Hall resistance. Furthermore, measurements on so-called van the Pauw-lamellas are presented. In this geometry the magneto-resistance shows a slope which refers to highly mobile conditions at the zero crossing of

  15. Chest tube insertion

    Science.gov (United States)

    Chest drainage tube insertion; Insertion of tube into chest; Tube thoracostomy; Pericardial drain ... Be careful there are no kinks in your tube. The drainage system should always sit upright and be placed ...

  16. Vibro-impact responses of a tube with tube--baffle interaction

    International Nuclear Information System (INIS)

    Shin, Y.S.; Sass, D.E.; Jendrzejczyk, J.A.

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments

  17. A Study On Critical Thinning In Thin-walled Tube Bending Of Al-Alloy 5052O Via Coupled Ductile Fracture Criteria

    International Nuclear Information System (INIS)

    Li Heng; Yang He; Zhan Mei

    2010-01-01

    Thin-walled tube bending(TWTB) method of Al-alloy tube has attracted wide applications in aerospace, aviation and automobile,etc. While, under in-plane double tensile stress states at the extrados of bending tube, the over-thinning induced ductile fracture is one dominant defect in Al-alloy tube bending. The main objective of this study is to predict the critical wall-thinning of Al-alloy tube bending by coupling two ductile fracture criteria(DFCs) into FE simulation. The DFCs include Continuum Damage Mechanics(CDM)-based model and GTN porous model. Through the uniaxial tensile test of the curved specimen, the basic material properties of the Al-alloy 5052O tube is obtained; via the inverse problem solution, the damage parameters of both the two fracture criteria are interatively determined. Thus the application study of the above DFCs in the TWTB is performed, and the more reasonable one is selected to obtain the critical thinning of Al-alloy tube in bending. The virtual damage initiation and evolution (when and where the ductile fracture occurs) in TWTB are investigated, and the fracture mechanisms of the voided Al-alloy tube in tube bending are consequently discussed.

  18. Tube Plugging Criterion for the TPCCW Heat Exchanger of Yonggwang NPP 1 and 2

    International Nuclear Information System (INIS)

    Kim, Hyung Nam; Yoo, Hyun Ju; Choi, Sung Nam; Song, Seok Yoon

    2009-01-01

    The turbine plant component cooling water(TPCCW) system circulates the cooling water to cool the components in the turbine building and discharges the heat from the components through the TPCCW heat exchanger. Recently, Yonggwang NPP 1 and 2 replaced the TPCCW heat exchanger because of tube degradation. The tubing material of new TPCCW heat exchanger of Yonggwang NPP 1 and 2 is titanium. If the tube wall cannot withstand the pressure, the cooling water with the chemicals flows into the tube side and it is discharged to the open water. The chemicals can pollute the open water. Therefore, the tubes of the TPCCW heat exchanger should be inspected and degraded tubes should be plugged. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. However, tubes have experienced leaks and failures and plugged based upon eddy current testing (ET) results. There are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. For this reason, the criteria for the tube wall thickness are addressed in order to operate the heat exchangers in nuclear power plant without trouble during the cycle. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. This method relies on the similar plugging criteria used in the steam generator

  19. Tube Plugging Criterion for the TPCCW Heat Exchanger of Yonggwang NPP 1 and 2

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hyung Nam; Yoo, Hyun Ju; Choi, Sung Nam; Song, Seok Yoon [Korea Electric Power Research Institute, Daejeon (Korea, Republic of)

    2009-05-15

    The turbine plant component cooling water(TPCCW) system circulates the cooling water to cool the components in the turbine building and discharges the heat from the components through the TPCCW heat exchanger. Recently, Yonggwang NPP 1 and 2 replaced the TPCCW heat exchanger because of tube degradation. The tubing material of new TPCCW heat exchanger of Yonggwang NPP 1 and 2 is titanium. If the tube wall cannot withstand the pressure, the cooling water with the chemicals flows into the tube side and it is discharged to the open water. The chemicals can pollute the open water. Therefore, the tubes of the TPCCW heat exchanger should be inspected and degraded tubes should be plugged. It is inevitable for the materials of the components to be degraded as the power plants become older. The degradation accompanies increasing maintenance cost as well as creating safety issues. The materials and wall thickness of heat exchanger tubes in nuclear power plants are selected to withstand system temperature, pressure, and corrosion. However, tubes have experienced leaks and failures and plugged based upon eddy current testing (ET) results. There are some problems for plugging the heat exchanger tubes since the criterion and its basis are not clearly described. For this reason, the criteria for the tube wall thickness are addressed in order to operate the heat exchangers in nuclear power plant without trouble during the cycle. There are many codes and standards to be referred for calculating the minimum thickness of the heat exchanger tube in the designing stage. However, the codes and standards related to show the tube plugging criteria may not exist currently. In this paper, a method to establish the tube plugging criteria of BOP heat exchangers, which is based on the USNRC Regulatory Guide 1.121, is introduced and the tube plugging criteria for the TPCCW heat exchanger of Yonggwang NPP No. 1 and 2. This method relies on the similar plugging criteria used in the steam generator

  20. Common Visual Preference for Curved Contours in Humans and Great Apes.

    Science.gov (United States)

    Munar, Enric; Gómez-Puerto, Gerardo; Call, Josep; Nadal, Marcos

    2015-01-01

    Among the visual preferences that guide many everyday activities and decisions, from consumer choices to social judgment, preference for curved over sharp-angled contours is commonly thought to have played an adaptive role throughout human evolution, favoring the avoidance of potentially harmful objects. However, because nonhuman primates also exhibit preferences for certain visual qualities, it is conceivable that humans' preference for curved contours is grounded on perceptual and cognitive mechanisms shared with extant nonhuman primate species. Here we aimed to determine whether nonhuman great apes and humans share a visual preference for curved over sharp-angled contours using a 2-alternative forced choice experimental paradigm under comparable conditions. Our results revealed that the human group and the great ape group indeed share a common preference for curved over sharp-angled contours, but that they differ in the manner and magnitude with which this preference is expressed behaviorally. These results suggest that humans' visual preference for curved objects evolved from earlier primate species' visual preferences, and that during this process it became stronger, but also more susceptible to the influence of higher cognitive processes and preference for other visual features.

  1. The creep and stress-rupture behaviour under internal pressure of tubes made from austenitic stainless steel X8 CrNiMoNb 1616 (Material No. 1.4981)

    International Nuclear Information System (INIS)

    Schaefer, L.; Polifka, F.; Kempe, H.

    1979-05-01

    Creep and stress rupture tests have been performed at 600, 650, 700 and 750 0 C on tubes made from three different heats from the austenitic stainless steel X8 CrNiMoNb 1616 (Material No. 1.4981). The tubes were loaded by internal pressure and the tangential (hoop) creep strain was measured continuously. The results are presented in form of creep curves, stress-time to rupture curves and curves for a creep limit. The average and minimum creep rates as a function of the applied stress have been evaluated and are described with a creep law analogous to Norton's creep law. An interpolation and extrapolation of the stress-rupture-strength and the creep strength are possible using the time-temperature-parameter-plot after Larson and Miller. (orig.) [de

  2. Three-dimensional numerical modeling of turbulent single-phase and two-phase flow in curved pipes

    International Nuclear Information System (INIS)

    Xin, R.C.; Dong, Z.F.; Ebadian, M.A.

    1996-01-01

    In this study, three-dimensional single-phase and two-phase flows in curved pipes have been investigated numerically. Two different pipe configurations were computed. When the results of the single-phase flow simulation were compared with the experimental data, a fairly good agreement was achieved. A flow-developing process has been suggested in single-phase flow, in which the turbulence is stronger near the outer tube wall than near the inner tube wall. For two-phase flow, the Eulerian multiphase model was used to simulate the phase distribution of a three-dimensional gas-liquid bubble flow in curved pipe. The RNG/κ-ε turbulence model was used to determine the turbulence field. An inlet gas void fraction of 5 percent was simulated. The gas phase effects on the liquid phase flow velocity have been examined by comparing the results of single-phase flow and two-phase flow. The findings show that for the downward flow in the U bend, the gas concentrates at the inner portion of the cross section at φ = π/18 - π/6 in most cases. The results of the phase distribution simulation are compared to experimental observations qualitatively and topologically

  3. Welding qualification procedure for fuel rods tubes of Zr-Sn alloys by the TIG automatic process

    International Nuclear Information System (INIS)

    1984-11-01

    It is presented the requirements to be used in the Welding qualification procedure for tubes of Zr-Sn alloys, specified in the ASTM B353 regulatory guide, used in the fabrication of fuel rods PWR reactors by the automatic TIG process. (E.G.) [pt

  4. The placement of naso-jejunal feeding tube under DSA guidance: its technology and skills

    International Nuclear Information System (INIS)

    Song Laichang; Wang Wenhui; Li Fenqiang; Su Dongjun; Li Bo

    2009-01-01

    Objective: To retrospectively analyze and summarize the manipulation and skills of the placement of naso-jejunal feeding tube under DSA guidance. Methods: After performing the spraying anesthesia of nasopharynx, the naso-jejunal feeding tube, with the help of guide wire and under DSA guidance, was placed into the proximal jejunum by passing it through the nose, pharynx, esophagus, stomach, pylorus and duodenum in order. The procedure was employed in 441 cases. Results: The mean time for performing the procedure was within five minutes. The procedure was successfully accomplished in all 441 cases and no complications occurred in this series. Conclusion: Under DSA guidance the placement of naso- jejunal feeding tube can be safely and quickly carried out with high successful rate and less sufferings to patient. It is worth popularizing this technique in clinical practice. (authors)

  5. Mechanical design of ceramic beam tube braze joints for NOvA kicker magnets

    Energy Technology Data Exchange (ETDEWEB)

    Ader, C.R.; Reilly, R.E.; Wilson, J.H.; /Fermilab

    2010-05-01

    The NO?A Experiment will construct a detector optimized for electron neutrino detection in the existing NuMI neutrino beam. The NuMI beam line is capable of operating at 400 kW of primary beam power and the upgrade will allow up to 700 kW. Ceramic beam tubes are utilized in numerous kicker magnets in different accelerator rings at Fermi National Accelerator Laboratory. Kovar flanges are brazed onto each beam tube end, since kovar and high alumina ceramic have similar expansion curves. The tube, kovar flange, end piece, and braze foil alloy brazing material are stacked in the furnace and then brazed. The most challenging aspect of fabricating kicker magnets in recent years have been making hermetic vacuum seals on the braze joints between the ceramic and flange. Numerous process variables can influence the robustness of conventional metal/ceramic brazing processes. The ceramic-filler metal interface is normally the weak layer when failure does not occur within the ceramic. Differences between active brazing filler metal and the moly-manganese process will be discussed along with the applicable results of these techniques used for Fermilab production kicker tubes.

  6. Detection of Babesia canis vogeli and Hepatozoon canis in canine blood by a single-tube real-time fluorescence resonance energy transfer polymerase chain reaction assay and melting curve analysis.

    Science.gov (United States)

    Kongklieng, Amornmas; Intapan, Pewpan M; Boonmars, Thidarut; Thanchomnang, Tongjit; Janwan, Penchom; Sanpool, Oranuch; Lulitanond, Viraphong; Taweethavonsawat, Piyanan; Chungpivat, Sudchit; Maleewong, Wanchai

    2015-03-01

    A real-time fluorescence resonance energy transfer polymerase chain reaction (qFRET PCR) coupled with melting curve analysis was developed for detection of Babesia canis vogeli and Hepatozoon canis infections in canine blood samples in a single tube assay. The target of the assay was a region within the 18S ribosomal RNA gene amplified in either species by a single pair of primers. Following amplification from the DNA of infected dog blood, a fluorescence melting curve analysis was done. The 2 species, B. canis vogeli and H. canis, could be detected and differentiated in infected dog blood samples (n = 37) with high sensitivity (100%). The detection limit for B. canis vogeli was 15 copies of a positive control plasmid, and for H. canis, it was 150 copies of a positive control plasmid. The assay could simultaneously distinguish the DNA of both parasites from the DNA of controls. Blood samples from 5 noninfected dogs were negative, indicating high specificity. Several samples can be run at the same time. The assay can reduce misdiagnosis and the time associated with microscopic examination, and is not prone to the carryover contamination associated with the agarose gel electrophoresis step of conventional PCR. In addition, this qFRET PCR method would be useful to accurately determine the range of endemic areas or to discover those areas where the 2 parasites co-circulate. © 2015 The Author(s).

  7. Pressure tube reactor

    International Nuclear Information System (INIS)

    Susuki, Akira; Murata, Shigeto; Minato, Akihiko.

    1993-01-01

    In a pressure tube reactor, a reactor core is constituted by arranging more than two units of a minimum unit combination of a moderator sealing pipe containing a calandria tube having moderators there between and a calandria tube and moderators. The upper header and a lower header of the calandria tank containing moderators are communicated by way of the moderator sealing tube. Further, a gravitationally dropping mechanism is disposed for injecting neutron absorbing liquid to a calandria gas injection portion. A ratio between a moderator volume and a fuel volume is defined as a function of the inner diameter of the moderator sealing tube, the outer diameter of the calandria tube and the diameter of fuel pellets, and has no influence to intervals of a pressure tube lattice. The interval of the pressure tube lattice is enlarged without increasing the size of the pressure tube, to improve production efficiency of the reactor and set a coolant void coefficient more negative, thereby enabling to improve self controllability and safety. Further, the reactor scram can be conducted by injecting neutron absorbing liquid. (N.H.)

  8. CFD Analysis of The Hydraulic Turbine Draft Tube to Improve System Efficiency

    Directory of Open Access Journals (Sweden)

    Chakrabarty Spandan

    2016-01-01

    Full Text Available Demand of the power is increasing day by day with the development of the science and technology. Development of the renewable energy sector has become essential issue at the present situation due to the limited source of the non-renewable energy. Hydro energy power generation sector is superior over the other renewable sector due to the high efficiency, ability to continuous generation and low generation cost. In India a great amount of the power generation is taken care by the hydro power system but still some more potential have unexplored. The efficiency improvement of the hydro turbine system can be done for the new installation or installed system by the improvement in component level. The system can be installed by the state of the art equipment, like modern inlet guide vane (IGV control system, improved design of the runner, IGV system, draft tube, penstock to reduce the loss, hence improve the efficiency. The energy recovery in the draft tube depends on the design of draft tube. In the present work the optimized design of the draft tube shape through computational fluid dynamics (CFD simulation has been carried out in ANSYS FLUENT platform. The design objective of the draft tube is to reduce the flow loss and improve the energy recovery, hence to improve the efficiency.

  9. Vertical steam generator with slab-type tube-plate with even tube bundle washing

    International Nuclear Information System (INIS)

    Manek, O.; Masek, V.; Motejl, V.; Quitta, R.

    1980-01-01

    A shielding plate supporting the tubes attached to the tube plate of a vertical steam generator is mounted above the tube plate. Tube sleeves are designed with a dimensional tolerance relative to the heat transfer tubes and the sleeve end and the tube plate end. A separate space is thus formed above the tube plate in which circulation or feed water is introduced to flow between the branch and the heat transfer tube. This provides intensive washing of heat transfer tubes at a critical point and prevents deposit formation, thus excluding heat transfer tube failures. (J.B.)

  10. Curves and surfaces for computer-aided geometric design a practical guide

    CERN Document Server

    Farin, Gerald

    1992-01-01

    A leading expert in CAGD, Gerald Farin covers the representation, manipulation, and evaluation of geometric shapes in this the Third Edition of Curves and Surfaces for Computer Aided Geometric Design. The book offers an introduction to the field that emphasizes Bernstein-Bezier methods and presents subjects in an informal, readable style, making this an ideal text for an introductory course at the advanced undergraduate or graduate level.The Third Edition includes a new chapter on Topology, offers new exercises and sections within most chapters, combines the material on Geometric Continuity i

  11. Use of CATHENA to model calandria-tube/moderator heat transfer after pressure-tube/calandria-tube ballooning contact

    International Nuclear Information System (INIS)

    Fan, H.Z.; Bilanovic, Z.; Nitheanandan, T.

    2004-01-01

    A study was performed to assess the effect of the calandria-tube/moderator heat transfer after pressure-tube/calandria tube ballooning contact using CATHENA. Results of this study indicated that the analytical tool, CATHENA, can be applied for pool boiling heat transfer on the external surface of a large diameter tube, such as the calandria tube used in CANDU reactors. The methodology in such CANDU-generic study can be used to simulate the tube surface with multiple boiling regimes and to assess the benefits of closely coupling thermalhydraulics modelling and fuel/fuel channel behaviour modelling. CATHENA (Canadian Algorithm for THErmalhydraulic Network Analysis) is a one-dimensional, two-fluid thermalhydraulic simulation code designed by AECL to analyse two-phase flow and heat transfer in piping networks. The detailed heat transfer package in CATHENA allows a connection to be established from the multiple solid surfaces of tubes to the surrounding large amount of moderator water, which acts as a heat sink during a postulated loss of coolant event. The generalized heat transfer package within CATHENA allows the tube walls to be divided into several layers in the radial direction and several sectors in the circumferential direction, to account for heat transfer conditions in these two directions. The CATHENA code with the generalized heat transfer package is capable of capturing key pool-boiling phenomena such as nucleate, transition and film boiling heat transfer as well as an ability to model the rewet phenomenon to some extent. A CATHENA input model was generated and used in simulations of selected contact boiling experiment test cases. The transient wall temperatures have been calculated in different portions of the calandria tube. By using this model an adequate agreement was achieved between CATHENA calculation and experimental measurement The CATHENA code enables one to investigate the transient and local thermal-mechanical behaviour of the calandria tube

  12. A Study on the Development of Nonglass Solar Vacuum Tube Collector

    International Nuclear Information System (INIS)

    Oh, Seung Jin

    2008-02-01

    Nature has been providing us energy from the beginning of the world. However human has hardly used it wisely. Solar energy is a kind of renewable energy from the nature. This study has been carried out to study the use of solar energy as it is harnessed in the form of thermal energy. Solar energy is one of the most promising energy resources such as hydrogen, biomass, wind and geothermal energy, because it is clean and inexhaustible. Space heating in buildings can be provided from solar energy by systems that are similar in many respects to water heater systems. By tapping into solar energy, we can not only solve the problem of energy shortage, but also can protect the environment and benefit the human beings. There are currently two types of evacuated tube; a single glass tube and a double glass tube. The former consists of a single glass tube which contains a flat or curved aluminium plate attached to a copper heat pipe or water flow pipe. The latter consists of rows of parallel transparent glass tubes, each of which contains an absorber tube. Evacuated tube collectors introduced above, however, pose some problems as they break rather easily under mechanical stresses. This paper introduces some preliminary results in design and fabrication of a non-glass solar vacuum tube collector in which the thermosyphon(heat pipe)made of copper is used as a heat transfer device. A series of tests have been performed to assess the ability of a non-glass solar vacuum tube collector. The series of experiments are as follows: 1)Vacuum level inside a vacuum tube. 2)Effects of the air remaining inside a vacuum tube on the temperature on the absorber plate. 3)Comparison of a non-glass vacuum solar collector with a single glass evacuated tube(SEIDO 5). Different vacuum levels inside non-glass vacuum tubes were applied to check any leakage or unexpected physical or chemical developments with time. The vacuum level changed from 10 -2 torr to 5torr in 5 days due to air infiltration from

  13. Efficacy of percutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts under CT guidance

    International Nuclear Information System (INIS)

    Huang Xiaoming; Huang Yongbin; Geng Lei; Zhang Haitao

    2008-01-01

    Objective: To evaluate the safety and efficacy of percutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts under CT guidance. Methods: Seventeen cases of giant hepatic and renal cyst were percutaneously implanted with 7 F pig tail drainage tube under CT guidance, together with daily injection of dehydrated ethanol or acetic acid. The drainage tube should be clamped after injection of sclerosing agent for cystic fluid 500 ml, immediate reopening of the drainage tube should be taken sright after the sclerotherapy. The withdrawal of drainage tube should be taken after resclerotherapy for all patients with < 10 ml of 24 h. drainage volume, including average of 40 d for hepatic cyst and 10 d for renal cyst. Results: 6 months after scletotherapy, all patients showed under US examination and 'healed' for all 17 cases, with successful rate up to 100%. No complication of bleeding, infection and cardioencephalovascular events occurred. Conclusion: CT guided pereutaneous sclerotherapy through pig tail drainage tube for giant hepatic and renal cysts is simple, safe and satisfactory efficacy. (authors)

  14. Thermal CFD Analysis of Tubular Light Guides

    Directory of Open Access Journals (Sweden)

    Ondřej Šikula

    2013-12-01

    Full Text Available Tubular light guides are applicable for daylighting of windowless areas in buildings. Despite their many positive indoor climate aspects they can also present some problems with heat losses and condensation. A computer CFD model focused on the evaluation of temperature distribution and air flow inside tubular light guides of different dimensions was studied. The physical model of the tested light guides of lengths more than 0.60 m proves shows that Rayleigh numbers are adequate for a turbulent air flow. The turbulent model was applied despite the small heat flux differences between the turbulent and laminar model. The CFD simulations resulted into conclusions that the growing ratio of length/diameter increases the heat transmission loss/linear transmittance as much as by 50 percent. Tubular light guides of smaller diameters have lower heat transmission losses compared to the wider ones of the same lengths with the same outdoor temperature being taken into account. The simulation results confirmed the thermal bridge effect of the tubular light guide tube inside the insulated flat roof details. The thermal transmittance of the studied light guides in the whole roof area was substituted with the point thermal bridges. This substitution gives possibility for simple thermal evaluation of the tubular light pipes in roof constructions.

  15. Improvement of pump tubes for gas guns and shock tube drivers

    Science.gov (United States)

    Bogdanoff, D. W.

    1990-01-01

    In a pump tube, a gas is mechanically compressed, producing very high pressures and sound speeds. The intensely heated gas produced in such a tube can be used to drive light gas guns and shock tubes. Three concepts are presented that have the potential to allow substantial reductions in the size and mass of the pump tube to be achieved. The first concept involves the use of one or more diaphragms in the pump tube, thus replacing a single compression process by multiple, successive compressions. The second concept involves a radical reduction in the length-to-diameter ratio of the pump tube and the pump tube piston. The third concept involves shock heating of the working gas by high explosives in a cyclindrical geometry reusable device. Preliminary design analyses are performed on all three concepts and they appear to be quite feasible. Reductions in the length and mass of the pump tube by factors up to about 11 and about 7, respectively, are predicted, relative to a benchmark conventional pump tube.

  16. Stapling and Section of the Nasogastric Tube during Sleeve Gastrectomy: How to Prevent and Recover

    Directory of Open Access Journals (Sweden)

    A. Péquignot

    2011-07-01

    Full Text Available Bariatric surgery has become an integral part of morbid obesity treatment with well-defined indications. Some complications, specific or not, due to laparoscopic sleeve gastrectomy (LSG procedure have recently been described. We report a rare complication unpublished to date: a nasogastric section during great gastric curve stapling. A 44-year-old woman suffered of severe obesity (BMI 36.6 kg/m2 with failure of medical treatments for years. According to already published technique, a LSG was performed. Six hours postoperatively, a nurse removed the nasogastric tube according to the local protocol and the nasogastric tube was abnormally short, with staples at its extremity. Surgery was performed with peroperative endoscopy. In conclusion, this is the first publication of a nasogastric section during LSG. Therefore we report this case and propose a solution to prevent its occurrence. To avoid this kind of accident, we now systematically insert the nasogastric tube by mouth through a Guedel cannula. Then, to insert the calibrating bougie, we entirely withdraw the nasogastric tube.

  17. Inspection qualification as a tool to risk based ET ISI of VVER type SG tubes

    International Nuclear Information System (INIS)

    Horacek, L.

    2002-01-01

    A Pilot study on Eddy current inspection qualification of VVER 440 steam generator tubes, discussed in this paper, followed the ENIQ methodology principles and covered briefly the assumed scope of ET qualification, relevant elaborated qualification documents, known ISI limitations and a review of input information on component and defects determined for Eddy current inspection qualification of VVER 440 steam generator tubes. The information includes the fabrication of the test blocks with SG tube segments provided by intended defect simulations of realistic SCC type and basic data on the realistic SCC type defects manufacturing technology. Lessons learned from the development of manufacturing technology of SSC type of defects, regional blind tests, elaboration of the preliminary technical justification for Eddy current automated inspections, potential optimisation of inspection procedures, laboratory and practical open trials are summarised in the paper. The results of the Pilot study also especially in relation to POD curve being determined seem to be useful for practical operational ISI programme and Risk informed ISI decisions and the establishment of plugging criteria of VVER 440 and VVER 1000 type steam generator tubes. (orig.)

  18. Peripheral nerve regeneration through P(DLLA-epsilon-CL) nerve guides

    NARCIS (Netherlands)

    Den Dunnen, WFA; Meek, MF; Robinson, PH; Schakernraad, JM

    1998-01-01

    P(DLLA-epsilon-CL) nerve guides can be used perfectly for short nerve gaps in rats, and are even better than short autologous nerve grafts. The tube dimensions, such as the internal diameter and wall thickness, are very important for the final outcome of peripheral nerve regeneration, as well as the

  19. Research and development on the hydraulic design system of the guide vanes of multistage centrifugal pumps

    International Nuclear Information System (INIS)

    Zhang, Q H; Xu, Y; Shi, W D; Lu, W G

    2012-01-01

    To improve the hydraulic design accuracy and efficiency of the guide vanes of the multistage centrifugal pumps, four different-structured guide vanes are investigated, and the design processes of those systems are established. The secondary development platforms of the ObjectArx2000 and the UG/NX OPEN are utilized to develop the hydraulic design systems of the guide vanes. The error triangle method is adopted to calculate the coordinates of the vanes, the profiles of the vanes are constructed by Bezier curves, and then the curves of the flow areas along the flow-path are calculated. Two-dimensional and three-dimensional hydraulic models can be developed by this system.

  20. TU-EF-204-07: Add Tube Current Modulation to a Low Dose Simulation Tool for CT Systems

    International Nuclear Information System (INIS)

    Ding, Y.; Wen, G.; Brown, K.; Klahr, P.; Dhanantwari, A.

    2015-01-01

    Purpose: We extended the capabilities of a low dose simulation tool to model Tube-Current Modulation (TCM). TCM is widely used in clinical practice to reduce radiation dose in CT scans. We expect the tool to be valuable for various clinical applications (e.g., optimize protocols, compare reconstruction techniques and evaluate TCM methods). Methods: The tube current is input as a function of z location, instead of a fixed value. Starting from the line integrals of a scan, a new Poisson noise realization at a lower dose is generated for each view. To validate the new functionality, we compared simulated scans with real scans in image space. Results: First we assessed noise in the difference between the low-dose simulations and the original high-dose scan. When the simulated tube current is a step function of z location, the noise at each segment matches the noise of 3 separate constant-tube-current-simulations. Secondly, with a phantom that forces TCM, we compared a low-dose simulation with an equivalent real low-dose scan. The mean CT number of the simulated scan and the real low-dose scan were 137.7±0.6 and 137.8±0.5 respectively. Furthermore, with 240 ROIs, the noise of the simulated scan and the real low-dose scan were 24.03±0.45 and 23.99±0.43 respectively, and they were not statistically different (2-sample t-test, p-value=0.28). The facts that the noise reflected the trend of the TCM curve, and that the absolute noise measurements were not statistically different validated the TCM function. Conclusion: We successfully added tube-current modulation functionality in an existing low dose simulation tool. We demonstrated that the noise reflected an input tube-current modulation curve. In addition, we verified that the noise and mean CT number of our simulation agreed with a real low dose scan. The authors are all employees of Philips. Yijun Ding is also supported by NIBIB P41EB002035 and NIBIB R01EB000803

  1. Vibro-impact responses of a tube with tube--baffle interaction. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Y S; Sass, D E; Jendrzejczyk, J A

    1978-01-01

    The relatively small, inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the vibrational characteristics and the response of the tube. Numerical studies were made to predict the vibro-impact response of a tube with tube-baffle interaction. The finite element method has been employed with a non-linear elastic contact spring-dashpot to model the effect of the relative approach between the tube and the baffle plate. The coupled equations of motion are directly integrated with a proportional system damping represented by a linear combination of mass and stiffness. Lumped mass approach with explicit time integration scheme was found to be a suitable choice for tube-baffle impacting analysis. Fourier analyses indicate that the higher mode contributions to the tube response are significant for strong tube-baffle impacting. The contact damping forces are negligible compared with the contact spring forces. The numerical analysis results are in reasonably good agreement with those of the experiments.

  2. Introduction to curved rotary tomographic apparatus 'TOMOREX'

    International Nuclear Information System (INIS)

    Kubota, Kazuo; Shinojima, Masayasu; Kohirasawa, Hideo; Tokui, Mitsuru

    1980-01-01

    In recent years, panorama X-ray photographic method is widely used for the X-ray diagnosis of teeth, jawbones and faces. One type based on the principle of tomography is curved surface rotary tomographic method utilizing fine-gap X-ray beam. With the synchronous rotation of an X-ray tube and a photographic film around a face, describing a U-shaped tomographic plane along a dental arch, an upper or lower jawbone is photographed. In the ''TOMOREX'' belonging to this type, is different tomographic planes are available, so that by selecting any position in advance, the part can be photographed. Furthermore, patients can be subjected to examination as laid on a stretcher. The mechanism and equipment, and the photographic method for eye sockets, cheekbones, upper jaw cavities and stereoscopic images are described. (J.P.N.)

  3. Heat transfer coefficient in pool boiling for an electrically heated tube at various inclinations

    International Nuclear Information System (INIS)

    Fahmy, A.S.A.; Mariy, A.H.; Mahmoud, S.I.; Ibrahim, N.A.

    1987-01-01

    An experimental investigation is carried out study the behaviour of heat transfer in pool boiling from a vertical and inclined heated tube at atmospheric pressure. An imperial correlation joining the different parameters affecting the heat transfer coefficient in pool boiling for an electrically heated tube at various inclinations is developed. Two test sections (zircaloy-4 and stainless steel) of 16 n n outer diameter and 120 nm length are investigated. Four levels of heat flux are used for heating the two lest sections (e.g. 381, 518, 721 and 929 k.watt/n 2). The maximum surface temperature achieved is 146.5 degree c for both materials, and the maximum bulk temperature is 95 degree C. It is found that the average heat transfer coefficient is inversely proportional with heated length l, where it reaches a constant value in the horizontal position. The heat transfer coefficient curves at various inclinations with respect to the heated tube length pass around one point which is defined as limit length

  4. Bender/Coiler for Tubing

    Science.gov (United States)

    Stoltzfus, J. M.

    1983-01-01

    Easy-to-use tool makes coils of tubing. Tubing to be bend clamped with stop post. Die positioned snugly against tubing. Operator turns handle to slide die along tubing, pushing tubing into spiral groove on mandrel.

  5. Stability study of MMC tubes and advanced assemblies for telescope structures

    Science.gov (United States)

    Nivet-Lutz, Martine; Pommatau, Gilles

    2017-11-01

    This paper presents new advances concerning the development of an Aluminum Matrix Composite for dimensionally stable satellite structures. Feasibility of thermally stable thin-walled tubes have been acquired through microstructure observation and Coefficient of Thermal Expansion measurement. In order to fit the thermo-mechanical stability domain of tubes on specifications, 3 thermal cycles have been tested, regarding to relaxation of internal stress and changes in macroscopic thermo-mechanical properties. Experimental expansion curves and microstructure observation show that thermal treatments permitts such a good fitting. For a better understanding of physical internal phenomena, internal stress has been measured by neutron diffraction on tube samples after each thermal treatment. Results show a significant decrease of stress due to cycling in cold temperature. In order to decrease the absolute value of CTE of assemblies, a new concept of thermo-mechanical stable linkage has been developped, which consists in a common alumlinum infiltration of superposed carbon preforms. Structural bonding, which usually affects stability properties and impose surface treatments and polymerization, can so be avoided. The study has been achieved through CNES (Centre National d'Etudes Spatiales) and French Ministry of Defense (DGA) supports.

  6. Sensitivity of the probability of failure to probability of detection curve regions

    International Nuclear Information System (INIS)

    Garza, J.; Millwater, H.

    2016-01-01

    Non-destructive inspection (NDI) techniques have been shown to play a vital role in fracture control plans, structural health monitoring, and ensuring availability and reliability of piping, pressure vessels, mechanical and aerospace equipment. Probabilistic fatigue simulations are often used in order to determine the efficacy of an inspection procedure with the NDI method modeled as a probability of detection (POD) curve. These simulations can be used to determine the most advantageous NDI method for a given application. As an aid to this process, a first order sensitivity method of the probability-of-failure (POF) with respect to regions of the POD curve (lower tail, middle region, right tail) is developed and presented here. The sensitivity method computes the partial derivative of the POF with respect to a change in each region of a POD or multiple POD curves. The sensitivities are computed at no cost by reusing the samples from an existing Monte Carlo (MC) analysis. A numerical example is presented considering single and multiple inspections. - Highlights: • Sensitivities of probability-of-failure to a region of probability-of-detection curve. • The sensitivities are computed with negligible cost. • Sensitivities identify the important region of a POD curve. • Sensitivities can be used as a guide to selecting the optimal POD curve.

  7. Radiation-resistant device with tubes for the introduction of a liquid, e.g., blood into a container holding a radioactive source

    International Nuclear Information System (INIS)

    Rasmussen, I.

    1978-01-01

    The invention concerns a radiation-resistant device with tubing for the introduction/removal of a liquid (e.g. blood to and from a patient) via an at least partly curved channel into and out of a container holding a radioactive source. A break is made with the idea that it is necessary to use a circular-cylindrical tube as introduction device for the material to be irradiated. If made of materials suitable for the purpose, such tubing is safe and compressible in the longitudinal direction. The disadvantages and limitations of earlier constructions can be ascribed to this circumstance. A characteristic of the present invention is an elongated, pressure-resistant insertion ''cage'', flexible in at least one direction, used for the introduction of a minimum of one tubing into the container through the channel. The tubing enters and leaves at the same end of the insert cage. (BP)

  8. Steam generator tube extraction

    International Nuclear Information System (INIS)

    Delorme, H.

    1985-05-01

    To enable tube examination on steam generators in service, Framatome has now developed a process for removing sections of steam generator tubes. Tube sections can be removed without being damaged for treating the tube section expanded in the tube sheet

  9. Modelling of time delay of electrical breakdown for nitrogen-filled tubes at pressures of 6.6 and 13.3 mbar in the increase region of the memory curve

    International Nuclear Information System (INIS)

    Nesic, N T; Ristic, G S; Pejovic, M M; Karamarkovic, J P

    2008-01-01

    Experimentally measured electrical breakdown time delay data versus the afterglow period (representing 'memory curves') for nitrogen-filled tubes at pressures of 6.6 and 13.3 mbar have been shown. The influence of N( 4 S) nitrogen atoms on secondary electron emission from the cathode (the SEE process) in late afterglow has been discussed. N( 4 S) atom concentration decay over relaxation time τ, N( 4 S)(τ), has been analysed by a numerical model and two analytical models. N( 4 S) decay analytical models are combined with different yield models that describe the SEE process by N( 4 S) and these combinations are employed to fit the experimental data. It has been shown that in late afterglow solving of very simple analytical equations instead of numerical solving of partial differential equations for N( 4 S)(τ) fitting can be used and that the combination of the first and the second order of the SEE process by N( 4 S) in yield modelling should be used in the case of 13.3 mbar pressure.

  10. Flood damage curves for consistent global risk assessments

    Science.gov (United States)

    de Moel, Hans; Huizinga, Jan; Szewczyk, Wojtek

    2016-04-01

    Assessing potential damage of flood events is an important component in flood risk management. Determining direct flood damage is commonly done using depth-damage curves, which denote the flood damage that would occur at specific water depths per asset or land-use class. Many countries around the world have developed flood damage models using such curves which are based on analysis of past flood events and/or on expert judgement. However, such damage curves are not available for all regions, which hampers damage assessments in those regions. Moreover, due to different methodologies employed for various damage models in different countries, damage assessments cannot be directly compared with each other, obstructing also supra-national flood damage assessments. To address these problems, a globally consistent dataset of depth-damage curves has been developed. This dataset contains damage curves depicting percent of damage as a function of water depth as well as maximum damage values for a variety of assets and land use classes (i.e. residential, commercial, agriculture). Based on an extensive literature survey concave damage curves have been developed for each continent, while differentiation in flood damage between countries is established by determining maximum damage values at the country scale. These maximum damage values are based on construction cost surveys from multinational construction companies, which provide a coherent set of detailed building cost data across dozens of countries. A consistent set of maximum flood damage values for all countries was computed using statistical regressions with socio-economic World Development Indicators from the World Bank. Further, based on insights from the literature survey, guidance is also given on how the damage curves and maximum damage values can be adjusted for specific local circumstances, such as urban vs. rural locations, use of specific building material, etc. This dataset can be used for consistent supra

  11. Seismic performance of recycled concrete-filled square steel tube columns

    Science.gov (United States)

    Chen, Zongping; Jing, Chenggui; Xu, Jinjun; Zhang, Xianggang

    2017-01-01

    An experimental study on the seismic performance of recycled concrete-filled square steel tube (RCFST) columns is carried out. Six specimens were designed and tested under constant axial compression and cyclic lateral loading. Two parameters, replacement percentage of recycled coarse aggregate (RCA) and axial compression level, were considered in the test. Based on the experimental data, the hysteretic loops, skeleton curves, ductility, energy dissipation capacity and stiffness degradation of RCFST columns were analyzed. The test results indicate that the failure modes of RCFST columns are the local buckling of the steel tube at the bottom of the columns, and the hysteretic loops are full and their shapes are similar to normal CFST columns. Furthermore, the ductility coefficient of all specimens are close to 3.0, and the equivalent viscous damping coefficient corresponding to the ultimate lateral load ranges from 0.323 to 0.360, which demonstrates that RCFST columns exhibit remarkable seismic performance.

  12. Content Analysis of Select YouTube Postings: Comparisons of Reactions to the Sandy Hook and Aurora Shootings and Hurricane Sandy.

    Science.gov (United States)

    Miller, Eric D

    2015-11-01

    This study details an innovative and methodical content analysis of 2,207 YouTube comments from four different YouTube videos (e.g., breaking news or memorials) related to the 2012 Sandy Hook Elementary School and Aurora theater mass shootings and the catastrophic Hurricane Sandy. As expected, YouTube comments associated with the Sandy Hook shootings (particularly those from a memorial video) were especially likely to feature compassion and grief with lessened hostility. This study highlights differing online contexts by which individuals show grief and related emotions following man-made and natural calamities and how-even in an online environment-powerful situational contexts greatly guide behavior.

  13. Use of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement

    International Nuclear Information System (INIS)

    Bae, Jae-Ik; Shin, Ji Hoon; Song, Ho-Young; Yoon, Chang Jin; Nam, Deok Ho; Choi, Won-Chan; Lim, Jin-Oh

    2005-01-01

    Our purpose was to assess the safety and usefulness of guiding sheaths in peroral fluoroscopic gastroduodenal stent placement. Two types of guiding sheath were made from straight polytetrafluoroethylene tubes. Type A was 80 cm in length, 4 mm in outer diameter and 3 mm in inner diameter. Type B was 70 cm in length, 6 mm in outer diameter and 5 mm in inner diameter. The type A sheath was used in 18 patients in whom a catheter-guide wire combination failed to pass through a stricture. The type B sheath was used in 22 patients in whom a stent delivery system failed to pass through the stricture due to loop formation within the gastric lumen. The overall success rate for guiding a catheter-guide wire through a stricture after using the type A sheath was 89%. The overall success rate for passing a stent delivery system through a stricture after using the type B sheath was 100%. All procedures were tolerated by the patients without any significant complications. The guiding sheaths were safe and useful in peroral fluoroscopic gastroduodenal stent placement. (orig.)

  14. Magnesium 1993 Maternal-Fetal Toxicology. A Clinician's Guide ...

    African Journals Online (AJOL)

    I S I G I 0 I M I. Maternal-Fetal Toxicology. A Clinician's. Guide. 2nd edition. Ed. by Gideon Koren. Pp. 824 ... analysis is presented, and survival curve ideas for effects over time. Final chapters ... SPSS-PC+, SAS and Nanostat. Several important.

  15. Effects of Dihedral Angle on Pool Boiling Heat Transfer from Two Tubes in Vertical Alignment

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Myeong-Gie [Andong National University, Andong (Korea, Republic of)

    2014-10-15

    One of the major issues in pool boiling heat transfer is a tube arrangement. The upper tube is affected by the lower tube and the enhancement of the heat transfer on the upper tube is estimated by the bundle effect ( h{sub r} ). It is defined as the ratio of the heat transfer coefficient ( h{sub b} ) for an upper tube in a bundle with lower tubes activated to that for the same tube activated alone in the bundle. Since heat transfer is related with the conditions of a tube surface, bundle geometries, and a liquid type, lots of studies have been carried out for the combinations of those parameters. The most effective parameter must be the tube pitch. Many researchers have been investigated its effect on heat transfer enhancement for the tube bundles and the tandem tubes. The heat transfer on the upper tube of the tubes is enhanced compared with the single tube. The upper tube within a tube bundle can significantly increase nucleate boiling heat transfer compared to the lower tubes at moderate heat fluxes. At high heat fluxes these influences disappear and the data merge onto the pool boiling curve of a single tube. It was explained that the major influential factor is the convective effects due to the fluid velocity and the rising bubbles. They used microstructure-R134a or FC-3184 combinations and identified that the increase in the heat flux of the lower tube decreased the superheat ( ∆T{sub sat} ) of the upper tube. The passive condensers adopted in SWR1000 and APR+ has U-type tubes. Those tubes are slightly inclined from the horizontal to prevent the occurrence of the water hammer. Since the pitch between the upper and lower tubes is varying along the tube length, the results for the fixed pitch are not applicable to the analysis of these condensers. Although there are lots of studies introducing results for the effects of inclination angle on pool boiling heat transfer, no results are treating the angle between two tubes. Therefore, the present study is aimed

  16. Chest Tube Drainage of the Pleural Space: A Concise Review for Pulmonologists.

    Science.gov (United States)

    Porcel, José M

    2018-04-01

    Chest tube insertion is a common procedure usually done for the purpose of draining accumulated air or fluid in the pleural cavity. Small-bore chest tubes (≤14F) are generally recommended as the first-line therapy for spontaneous pneumothorax in non-ventilated patients and pleural effusions in general, with the possible exception of hemothoraces and malignant effusions (for which an immediate pleurodesis is planned). Large-bore chest drains may be useful for very large air leaks, as well as post-ineffective trial with small-bore drains. Chest tube insertion should be guided by imaging, either bedside ultrasonography or, less commonly, computed tomography. The so-called trocar technique must be avoided. Instead, blunt dissection (for tubes >24F) or the Seldinger technique should be used. All chest tubes are connected to a drainage system device: flutter valve, underwater seal, electronic systems or, for indwelling pleural catheters (IPC), vacuum bottles. The classic, three-bottle drainage system requires either (external) wall suction or gravity ("water seal") drainage (the former not being routinely recommended unless the latter is not effective). The optimal timing for tube removal is still a matter of controversy; however, the use of digital drainage systems facilitates informed and prudent decision-making in that area. A drain-clamping test before tube withdrawal is generally not advocated. Pain, drain blockage and accidental dislodgment are common complications of small-bore drains; the most dreaded complications include organ injury, hemothorax, infections, and re-expansion pulmonary edema. IPC represent a first-line palliative therapy of malignant pleural effusions in many centers. The optimal frequency of drainage, for IPC, has not been formally agreed upon or otherwise officially established. Copyright©2018. The Korean Academy of Tuberculosis and Respiratory Diseases.

  17. Feeding tube - infants

    Science.gov (United States)

    ... this page: //medlineplus.gov/ency/article/007235.htm Feeding tube - infants To use the sharing features on this page, please enable JavaScript. A feeding tube is a small, soft, plastic tube placed ...

  18. Radiologically guided percutaneous pleurodesis of malignant pleural effusion

    International Nuclear Information System (INIS)

    Morrison, M.C.; Mueller, P.R.; Saini, S.; Hahn, P.F.; Lee, M.J.; Cortell, E.; Girard, M.; Goldberg, M.; Simeone, J.F.

    1990-01-01

    This paper reports that in patients with symptomatic malignant pleural effusion. US-guided placement of small-bore catheters for pleurodesis presents an alternative to traditional surgical management. Catheters ranging in size from 7-F to 16-F (n = 17), or greater than 16-F (n = 5), were placed intrapleurally under US guidance in 22 patients with symptomatic malignant pleural effusion. Pleur-E-Vac suction was applied until tube drainage was less than 100 mL/d. Tetracycline (1--2 g/100 mL of normal saline solution) or bleomycin (45--100 U/50 mL of 5% dextrose) was then instilled and left in the pleural space for 1--3 hours. The chest tube was removed when output was less than 20 mL/d

  19. X-Ray Flare Oscillations Track Plasma Sloshing along Star-disk Magnetic Tubes in the Orion Star-forming Region

    Science.gov (United States)

    Reale, Fabio; Lopez-Santiago, Javier; Flaccomio, Ettore; Petralia, Antonino; Sciortino, Salvatore

    2018-03-01

    Pulsing X-ray emission tracks the plasma “echo” traveling in an extremely long magnetic tube that flares in an Orion pre-main sequence (PMS) star. On the Sun, flares last from minutes to a few hours and the longest-lasting ones typically involve arcades of closed magnetic tubes. Long-lasting X-ray flares are observed in PMS stars. Large-amplitude (∼20%), long-period (∼3 hr) pulsations are detected in the light curve of day-long flares observed by the Advanced CCD Imaging Spectrometer on-board Chandra from PMS stars in the Orion cluster. Detailed hydrodynamic modeling of two flares observed on V772 Ori and OW Ori shows that these pulsations may track the sloshing of plasma along a single long magnetic tube, triggered by a sufficiently short (∼1 hr) heat pulse. These magnetic tubes are ≥20 solar radii long, enough to connect the star with the surrounding disk.

  20. Guide to Using Onionskin Analysis Code (U)

    Energy Technology Data Exchange (ETDEWEB)

    Fugate, Michael Lynn [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Statistical Sciences Group; Morzinski, Jerome Arthur [Los Alamos National Lab. (LANL), Los Alamos, NM (United States). Statistical Sciences Group

    2016-09-15

    This document is a guide to using R-code written for the purpose of analyzing onionskin experiments. We expect the user to be very familiar with statistical methods and the R programming language. For more details about onionskin experiments and the statistical methods mentioned in this document see Storlie, Fugate, et al. (2013). Engineers at LANL experiment with detonators and high explosives to assess performance. The experimental unit, called an onionskin, is a hemisphere consisting of a detonator and a booster pellet surrounded by explosive material. When the detonator explodes, a streak camera mounted above the pole of the hemisphere records when the shock wave arrives at the surface. The output from the camera is a two-dimensional image that is transformed into a curve that shows the arrival time as a function of polar angle. The statistical challenge is to characterize a baseline population of arrival time curves and to compare the baseline curves to curves from a new, so-called, test series. The hope is that the new test series of curves is statistically similar to the baseline population.

  1. Approach to the HTGR core outlet temperature measurements in the United States

    International Nuclear Information System (INIS)

    Franklin, R.; Rodriguez, C.

    1982-06-01

    The High Temperature Gas-Cooled Reactor (HTGR) constructed at Fort St. Vrain Colorado (330 MWe) used Geminol thermocouples to measure the primary coolant temperature at the core outlet. The primary coolant (helium) is heated by the graphite core to temperatures in the range of 700 deg. to 750 deg. C. The combination of the high temperature, high flow rate and radiation at the core outlet area makes it difficult to obtain accurate temperature measurements. The Geminol thermocouples installed in the Fort St. Vrain reactor have provided accurate data for several years of power operation without any failures. The indicated temperature of the core outlet thermocouples agrees with a ''traversing'' thermocouple measurement to within +-2 deg. C. The Geminol thermocouple wire was provided by the Driver-Harris Company and is similar to the chromel versus alumel thermocouple. Geminol wire is no longer distributed and on future designs, chromel versus alumel wire will be used. The next large HTGR design, which is being performed with funding support from the United States Department of Energy, will incorporate replaceable thermocouples. The thermocouples used in the Fort St. Vrain reactor were permanently installed and large in diameter (6.35 mm) to insure good reliability. The replaceable thermocouples to be used in the next large reactor will be smaller in diameter (3.18 mm). These replaceable thermocouples will be inserted into the core outlet area through long curved guide tubes that are permanently installed. These guide tubes are as long as 18 meters and must be curved to reach the core outlet regions. Tests were conducted to prove that the thermocouples could be inserted and removed through the long curved guide tubes. (author)

  2. Magnetic properties of multisegmented cylindrical nanoparticles with alternating magnetic wire and tube segments

    Energy Technology Data Exchange (ETDEWEB)

    Salazar-Aravena, D.; Corona, R.M. [Departamento de Física, Universidad de Santiago de Chile (USACH), Avda. Ecuador 3493, 917-0124 Santiago (Chile); Goerlitz, D.; Nielsch, K. [Institute of Applied Physics, University of Hamburg, Jungiusstrasse 11, D-20355 Hamburg (Germany); Escrig, J., E-mail: jescrigm@gmail.com [Departamento de Física, Universidad de Santiago de Chile (USACH), Avda. Ecuador 3493, 917-0124 Santiago (Chile); Center for the Development of Nanoscience and Nanotechnology (CEDENNA), Avda. Ecuador 3493, 917-0124 Santiago (Chile)

    2013-11-15

    The magnetic properties in multisegmented cylindrical nanostructures comprised of nanowire and nanotube segments are investigated numerically as a function of their geometry. In this work we report systematic changes in the coercivity and remanence in these systems. Besides, we have found the ideal conditions for a magnetic configuration with two antiparallel domains that could be used to help to stabilize magnetic nanoparticles inside ferromagnetic multisegmented cylindrical nanoparticles. This magnetic behavior is due to the fact that the tube segment reverses its magnetization before the wire segment, allowing the control of the magnetic domain walls motion between two segments. In this way, these magnetic nanoobjects can be an alternative to store information or even perform logic functions. - Highlights: • Magnetic states of wire/tube were investigated as a function of their geometry. • Multisegmented systems present two well-defined jumps in the hysteresis curve. • It is possible to prepare an antiparallel magnetic configuration. • The step width for the optimum condition reaches 60 mT. • The tube segments reverse their magnetization first than the wire segments.

  3. An intermetallic powder-in-tube approach to increased flux-pinning in Nb3Sn by internal oxidation of Zr

    Science.gov (United States)

    Motowidlo, L. R.; Lee, P. J.; Tarantini, C.; Balachandran, S.; Ghosh, A. K.; Larbalestier, D. C.

    2018-01-01

    We report on the development of multifilamentary Nb3Sn superconductors by a versatile powder-in-tube technique (PIT) that demonstrates a simple pathway to a strand with a higher density of flux-pinning sites that has the potential to increase critical current density beyond present levels. The approach uses internal oxidation of Zr-alloyed Nb tubes to produce Zr oxide particles within the Nb3Sn layer that act as a dispersion of artificial pinning centres (APCs). In this design, SnO2 powder is mixed with Cu5Sn4 powder within the PIT core that supplies the Sn for the A15 reaction with Nb1Zr filament tubes. Initial results show an average grain size of ˜38 nm in the A15 layer, compared to the 90-130 nm of typical APC-free high-J c strands made by conventional PIT or Internal Sn processing. There is a shift in the peak of the pinning force curve from H/H irr of ˜0.2 to ˜0.3 and the pinning force curves can be deconvoluted into grain boundary and point-pinning components, the point-pinning contribution dominating for the APC Nb-1wt%Zr strands.

  4. Development of a guidance guide for dosimetry in computed tomography

    International Nuclear Information System (INIS)

    Fontes, Ladyjane Pereira

    2016-01-01

    Due to frequent questions from users of ionization chambers pencil type calibrated in the Instrument Calibration Laboratory of the Institute of Energy and Nuclear Research (LCI - IPEN), on how to properly apply the factors indicated in their calibration certificates, a guide was prepared guidance for dosimetry in computed tomography. The guide includes guidance prior knowledge of half value layer (HVL), as it is necessary to know the effective beam energy for application quality for correction factor (kq). The evaluation of HVL in TC scanners becomes a difficult task due to system geometry and therefore a survey was conducted of existing methodologies for the determination of HVL in clinical beams Computed Tomography, taking into account technical, practical and economic factors. In this work it was decided to test a Tandem System consists of absorbing covers made in the workshop of IPEN, based on preliminary studies due to low cost and good response. The Tandem system consists of five cylindrical absorbing layers of 1mm, 3mm, 5mm, 7mm and 10mm aluminum and 3 cylindrical absorbing covers 15mm, 25mm and acrylic 35mm (PMMA) coupled to the ionization chamber of commercial pencil type widely used in quality control tests in dosimetry in clinical beams Computed tomography. Through Tandem curves it was possible to assess HVL values and from the standard curve pencil-type ionization chamber, Kq find the appropriate beam. The elaborate Guide provides information on how to build the calibration curve on the basis of CSR, to find the Kq and information for construction Tandem curve, to find values close to CSR. (author)

  5. Accurate pre-surgical determination for self-drilling miniscrew implant placement using surgical guides and cone-beam computed tomography.

    Science.gov (United States)

    Miyazawa, Ken; Kawaguchi, Misuzu; Tabuchi, Masako; Goto, Shigemi

    2010-12-01

    Miniscrew implants have proven to be effective in providing absolute orthodontic anchorage. However, as self-drilling miniscrew implants have become more popular, a problem has emerged, i.e. root contact, which can lead to perforation and other root injuries. To avoid possible root damage, a surgical guide was fabricated and cone-beam computed tomography (CBCT) was used to incorporate guide tubes drilled in accordance with the planned direction of the implants. Eighteen patients (5 males and 13 females; mean age 23.8 years; minimum 10.7, maximum 45.5) were included in the study. Forty-four self-drilling miniscrew implants (diameter 1.6, and length 8 mm) were placed in interradicular bone using a surgical guide procedure, the majority in the maxillary molar area. To determine the success rates, statistical analysis was undertaken using Fisher's exact probability test. CBCT images of post-surgical self-drilling miniscrew implant placement showed no root contact (0/44). However, based on CBCT evaluation, it was necessary to change the location or angle of 52.3 per cent (23/44) of the guide tubes prior to surgery in order to obtain optimal placement. If orthodontic force could be applied to the screw until completion of orthodontic treatment, screw anchorage was recorded as successful. The total success rate of all miniscrews was 90.9 per cent (40/44). Orthodontic self-drilling miniscrew implants must be inserted carefully, particularly in the case of blind placement, since even guide tubes made on casts frequently require repositioning to avoid the roots of the teeth. The use of surgical guides, fabricated using CBCT images, appears to be a promising technique for placement of orthodontic self-drilling miniscrew implants adjacent to the dental roots and maxillary sinuses.

  6. Percolation theory and its application for interpretation of soil water retention curves

    International Nuclear Information System (INIS)

    Kodesova, R.

    2004-01-01

    The soil porous system has traditionally been deduced from the soil-water retention curve with the assumption of homogeneity and free accessibility of pores, defined as capillary tubes, from the sink/source of water. But real soil fabric is mostly characterized by aggregates. In this case, the soil porous system cannot be modeled as a homogeneous one. To examine the differences between homogeneous and heterogeneous soil porous systems, we studied two types of soils: sandy soil and coarse sandy soil. We applied image processing filters and the ARC/INFO Grid module to analyze pore sizes in both soils from their electron microscope images taken at two different magnifications. We used the resulting pore-size distribution data to generate 3-D porous media consisting of pores and throats. The homogeneous pore structure was created as a mono-modal pore-throat network with one pore-size distribution. The heterogeneous pore structure was designed as a bi-modal pore-throat network with two pore-size distributions, where the pore sizes were hierarchically arranged in the nodes of the network. We applied the percolation model to simulate water and air displacement in these networks. The distribution of water in the nodes of the networks was studied increasing/decreasing steps of pressure head and the drainage and wetting branches of the retention curves were evaluated. The soil-water retention curves modeled for the mono-modal and bi-modal porous systems had different characters. The simulated shape of the retention curve in the mono-modal case was close to the step-like form of a retention curve characteristic of unstructured soil. The shape of the simulated retention curve in the bi-modal case was smoother, more gradual, and closer to the shape of the retention curve of a real, structured soil. (author)

  7. Effect of tube potential and image receptor on the detection of natural proximal caries in primary teeth.

    Science.gov (United States)

    Sogur, Elif; Baksı, B Güniz; Orhan, Kaan; Paksoy, S Candan; Dogan, Salih; Erdal, Yılmaz S; Mert, Ali

    2011-12-01

    The aim of this study was to assess the detection of proximal caries in primary teeth at three different tube potentials using Ektaspeed films, storage phosphor plates (SPPs), and a charge-coupled device (CCD). Fifty-three extracted human primary molars with natural proximal caries were radiographed with three different imaging modalities--Digora Optime SPP system, RVGui CCD system, and Ektaspeed films--at 50-, 65-, and 70-kV tube potentials. Three observers scored the resultant images for the presence or absence of caries. The definitive diagnosis was determined by stereomicroscopic assessment. The diagnostic accuracy for each imaging modality was expressed as the area under the receiver operating characteristic curves (A(z)). Differences among the A(z) values were assessed using two-way ANOVA and t tests. Kappa was used to measure inter- and intra-observer agreement. Higher accuracy was found for SPPs compared to film and CCD images at all tube potentials. Accuracy was significantly different only at 50-kV tube setting in favor of SPPs (p tube potential for the diagnosis of proximal caries since further advantages include the elimination of chemical processing, image enhancement, and a better low-contrast detectability performance.

  8. Biological radiation dose estimation by chromosomal aberrations analysis in human peripheral blood (dose-effect curve)

    International Nuclear Information System (INIS)

    Al-Achkar, W.

    2001-09-01

    In order to draw a dose-effect curve, experimentally gamma ray induced chromosomal aberrations in human peripheral lymphocytes from eight healthy people were studied. Samples from 4 males and 4 females were irradiated in tubes with 0.15, 0.25, 0.5, 1, 1.5, 2, 2.5 gray of gamma ray (Co 60 at dose rate 0.3 Gy/min). Irradiated and control samples were incubated in 37 centigrade for 48 hours cell cultures. Cell cultures then were stopped and metaphases spread, Giemsa stained to score the induced chromosomal aberrations. Chromosomal aberrations from 67888 metaphases were scored. Curves from the total number of dicentrics, dicentrics + rings and total numbers of breaks in cell for each individual or for all people were drawn. An increase of all chromosomal aberrations types with the elevation of the doses was observed. The yield of chromosome aberrations is related to the dose used. These curves give a quick useful estimation of the accidentally radiation exposure. (author)

  9. Preliminary design of high-power wave-guide/transmission system for multimegawatt CW requirements of 100 MeV proton Linac

    International Nuclear Information System (INIS)

    Shrivastava, Purushottam; Wanmode, Y.D.; Hannurkar, P.R.

    2002-01-01

    Development of a 100 MeV CW proton Linac has been planned at CAT. This Linac will be needing CW rf power in the frequency ranges of 350 MHz and 700 MHz for its RFQ and DTL/CCDTL/SFDTL structures respectively. The power to the accelerating structures will be produced by either 1 MW CW or 250 kW CW klystron/inductive output tubes (HOM IOTs). The power needed by respective feed points in the structure is max. 250 kW which will be powered by splitting the power from 1 MW klystron/klystrode into four channels by using a wave-guide system. In case of using 250 kW tubes the power to the structures will be provided directly from each tube. Two types of wave-guide transmission system have been considered, viz WR 2300 for 350 MHz rf needs and WR 1500 for 700 MHz rf needs. The typical wave-guide system has been designed using the 1 MW CW klystron followed by wave-guide filter, dual directional coupler, high-power circulator, three 3 dB magic TEE power dividers to split the main channel into four equal channels of 250 kW each. Each individual channel has dual directional couplers, flexible wave-guide sections and high power ceramic vacuum window. The circulator and each power divider is terminated into the isolated ports by high power CW loads. Out of the four channels three channels have phase shifters. Present paper describes the technological aspects and design specifications-considerations for these stringent requirements. (author)

  10. Eustachian tube patency

    Science.gov (United States)

    Eustachian tube patency refers to how much the eustachian tube is open. The eustachian tube runs between the middle ear and the throat. It controls the pressure behind the eardrum and middle ear space. This helps keep ...

  11. Effect of tube-support interaction on the dynamic responses of heat exchanger tubes

    International Nuclear Information System (INIS)

    Shin, Y.S.; Jendrzejczyk, J.A.; Wambsganss, M.W.

    1977-01-01

    Operating heat exchangers have experienced tube damages due to excessive flow-induced vibration. The relatively small inherent tube-to-baffle hole clearances associated with manufacturing tolerances in heat exchangers affect the tube vibrational characteristics. In attempting a theoretical analysis, questions arise as to the effects of tube-baffle impacting on dynamic responses. Experiments were performed to determine the effects of tube-baffle impacting in vertical/horizontal tube orientation, and in air/water medium on the vibrational characteristics (resonant frequencies, mode shapes, and damping) and displacement response amplitudes of a seven-span tube model. The tube and support conditions were prototypic, and overall length approximately one-third that of a straight tube segment of the steam generator designed for the CRBR. The test results were compared with the analytical results based on the multispan beam with ''knife-edge'' supports

  12. Standard guide for mutual inductance bridge applications for wall thickness determinations in boiler tubing

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2010-01-01

    1.1 This guide describes a procedure for obtaining relative wall thickness indications in ferromagnetic and non-ferromagnetic steels using the mutual inductance bridge method. The procedure is intended for use with instruments capable of inducing two substantially identical magnetic fields and noting the change in inductance resulting from differing amounts of steel. It is used to distinguish acceptable wall thickness conditions from those which could place tubular vessels or piping at risk of bursting under high temperature and pressure conditions. 1.2 This guide is intended to satisfy two general needs for users of industrial Mutual Inductance Bridge (MIB) equipment: (1) the need for a tutorial guide addressing the general principles of Mutual Inductance Bridges as they apply to industrial piping; and (2) the need for a consistent set of MIB performance parameter definitions, including how these performance parameters relate to MIB system specifications. Potential users and buyers, as well as experienced M...

  13. Fracture toughness behaviour using small CCT specimen of Zr-2.5Nb pressure tube materials

    International Nuclear Information System (INIS)

    Oh, Dong Joon; Kim, Young Suk; Ahn, Sang Bok; Im, Kyung Soo; Kwon, Sang Chul; Cheong, Yong Mu

    2001-03-01

    Fracture toughness of Zr-2.5Nb pressure tube is the essential data to estimate the CCL(critical crack length) for the concept of LBB(Leak-Before-Break) in PHWR. Zr-2.5Nb pressure tubes could be degraded due to the absorption of hydrogen from coolant and the irradiation. To investigate the fracture toughness behaviour such as J-resistance curves, dJ/da, and CCL of some Zr-alloys (CANDU-double, -quad, CW-E125, TMT-E125, E-635), the transverse tensile test and the fracture toughness test of small CCT (Curved Compact Tension) specimen with 17 mm width were carried out with the variation of testing temperature at different testing condition. To define the fracture mechanism of degradation, the fractographic comparison of fracture surface was performed using the stereoscope and SEM. In addition, the effect of non-uniformed pre-fatigue crack was also studied. In conclusion, CANDU double-melted was less tougher than CANDU quad-melted and the hydrogen embrittlement was found at room temperature. Finally, while the effect of non-uniformed pre-fatigue crack was considerable at room temperature, this effect was disappeared at 250-300 .deg. C

  14. Annular gap measurement between pressure tube and calandria tube by eddy current technique

    International Nuclear Information System (INIS)

    Bhole, V.M.; Rastogi, P.K.; Kulkarni, P.G.

    1992-01-01

    In pressurised heavy water reactor (PHWR) major distinguishing feature is that there are number of identical fuel channels in the reactor core. Each channel consists of pressure tube of Zr-2.5 Nb or zircaloy-2 through which high temperature, high pressure primary coolant is passing. The pressure tube contains fuel. Surrounding the pressure tube there is low pressure, cool heavy water (moderator). The moderator is thermally separated from coolant by the tube which is nominally concentric with pressure tube called calandria tube. There are four garter springs in the annular gap between pressure tube and calandria tube. During the life of the reactor there are number of factors by which the pressure tube sags, most important factors are irradiation creep, thermal creep, fuel load etc. Because of the sag of pressure tube it can touch the calandria tube resulting in formation of cold spot. This leads to hydrogen concentration at that spot by which the material at that place becomes brittle and can lead to catastrophic failure of pressure tube. There is no useful access for measurement of annular gap either through the gas annular space or from exterior of calandria tube. So the annular gap was measured from inside surface of pressure tube which is accessible. Eddy current technique was used for finding the gap. The paper describe the details of split coil design of bobbin probe, selection of operating point on normalised impedance diagram by choosing frequency. Experimental results on full scale mock up, and actual gap measurement in reactor channel, are also given. (author). 7 figs

  15. Categorising YouTube

    DEFF Research Database (Denmark)

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube......’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a user-driven bottom-up folksonomy and a hierarchical browsing system that emphasises a culture of competition...... and which favours the already popular content of YouTube. With this taxonomic approach, the UGC videos are registered and analysed in terms of empirically based observations. The article identifies various UGC categories and their principal characteristics. Furthermore, general tendencies of the UGC within...

  16. Theoretical and computational analysis of IFR beam transport on curved channels

    International Nuclear Information System (INIS)

    Rienstra, W.W.

    1987-01-01

    With the successful demonstration at Sandia National Laboratory and at Lawrence Livermore Laboratory of ion focused regime (IFR) electron beam guiding in accelerators there has developed interest in using IFR channels to steer beams along curved paths. The authors report the calculations of the expected emittance growth from such channels and the results of the TRACKER code simulations of IFR steering with the assistance of strong focus sector magnets

  17. Determination of the fracture thoughness curve within the ductile brittle transition region in ferritic steel AISI4140

    International Nuclear Information System (INIS)

    Hernandez, R.; Orozco, E.

    1996-01-01

    The aim of this work is to show the validity in the employment of small test tubes (1/2 T) in order to determine the fracture thoughness in ferritic steels that experience the beginning of cracking by cleavage, to elastic instability, and/or elasto-plastic. It was calculated the change of fracture thoughness in the ductile brittle transition region like function of the temperature employing statistic methods for steel to the annealed carbon of the type AISI4140. The testings were carried out within an interval of temperatures, where the cracking by cleavage and/or pop-in occurs. The thoughness curve of the cracking in the transition region was determined, in small test tubes 1/2 T, and in standard test tubes, 1T. It was calculated the beginning of instability of the integral J, J IC , and was converted to its equivalent in K JC units based in the ASTM Standard rev. 6-12-95 (ref. 6). (Author)

  18. Head losses prediction and analysis in a bulb turbine draft tube under different operating conditions using unsteady simulations

    Science.gov (United States)

    Wilhelm, S.; Balarac, G.; Métais, O.; Ségoufin, C.

    2016-11-01

    Flow prediction in a bulb turbine draft tube is conducted for two operating points using Unsteady RANS (URANS) simulations and Large Eddy Simulations (LES). The inlet boundary condition of the draft tube calculation is a rotating two dimensional velocity profile exported from a RANS guide vane- runner calculation. Numerical results are compared with experimental data in order to validate the flow field and head losses prediction. Velocity profiles prediction is improved with LES in the center of the draft tube compared to URANS results. Moreover, more complex flow structures are obtained with LES. A local analysis of the predicted flow field using the energy balance in the draft tube is then introduced in order to detect the hydrodynamic instabilities responsible for head losses in the draft tube. In particular, the production of turbulent kinetic energy next to the draft tube wall and in the central vortex structure is found to be responsible for a large part of the mean kinetic energy dissipation in the draft tube and thus for head losses. This analysis is used in order to understand the differences in head losses for different operating points. The numerical methodology could then be improved thanks to an in-depth understanding of the local flow topology.

  19. Pressure tube type reactors

    International Nuclear Information System (INIS)

    Komada, Masaoki.

    1981-01-01

    Purpose: To increase the safety of pressure tube type reactors by providing an additional ECCS system to an ordinary ECCS system and injecting heavy water in the reactor core tank into pressure tubes upon fractures of the tubes. Constitution: Upon fractures of pressure tubes, reduction of the pressure in the fractured tubes to the atmospheric pressure in confirmed and the electromagnetic valve is operated to completely isolate the pressure tubes from the fractured portion. Then, the heavy water in the reactor core tank flows into and spontaneously recycles through the pressure tubes to cool the fuels in the tube to prevent their meltdown. By additionally providing the separate ECCS system to the ordinary ECCS system, fuels can be cooled upon loss of coolant accidents to improve the safety of the reactors. (Moriyama, K.)

  20. Tube-in-shell heat exchangers

    International Nuclear Information System (INIS)

    Richardson, J.

    1976-01-01

    Tube-in-shell heat exchangers normally comprise a bundle of parallel tubes within a shell container, with a fluid arranged to flow through the tubes in heat exchange with a second fluid flowing through the shell. The tubes are usually end supported by the tube plates that separate the two fluids, and in use the tube attachments to the tube plates and the tube plates can be subject to severe stress by thermal shock and frequent inspection and servicing are required. Where the heat exchangers are immersed in a coolant such as liquid Na such inspection is difficult. In the arrangement described a longitudinally extending central tube is provided incorporating axially spaced cylindrical tube plates to which the opposite ends of the tubes are attached. Within this tube there is a tubular baffle that slidably seals against the wall of the tube between the cylindrical tube plates to define two co-axial flow ducts. These ducts are interconnected at the closed end of the tube by the heat exchange tubes and the baffle comprises inner and outer spaced walls with the interspace containing Ar. The baffle is easily removable and can be withdrawn to enable insertion of equipment for inspecting the wall of the tube and tube attachments and to facilitate plugging of defective tubes. Cylindrical tube plates are believed to be superior for carrying pressure loads and resisting the effects of thermal shock. Some protection against thermal shock can be effected by arranging that the secondary heat exchange fluid is on the tube side, and by providing a thermal baffle to prevent direct impingement of hot primary fluid on to the cylindrical tube plates. The inner wall of the tubular baffle may have flexible expansible region. Some nuclear reactor constructions incorporating such an arrangement are described, including liquid metal reactors. (U.K.)

  1. Observation of "YouTube" Language Learning Videos ("YouTube" LLVS)

    Science.gov (United States)

    Alhamami, Munassir

    2013-01-01

    This paper navigates into the "YouTube" website as one of the most usable online tools to learn languages these days. The paper focuses on two issues in creating "YouTube" language learning videos: pedagogy and technology. After observing the existing "YouTube" LLVs, the study presents a novel rubric that is directed…

  2. Modelling of creep curves of Ni3Ge single crystals

    Science.gov (United States)

    Starenchenko, V. A.; Starenchenko, S. V.; Pantyukhova, O. D.; Solov'eva, Yu V.

    2015-01-01

    In this paper the creep model of alloys with L12 superstructure is presented. The creep model is based on the idea of the mechanisms superposition connected with the different elementary deformation processes. Some of them are incident to the ordered structure L12 (anomalous mechanisms), others are typical to pure metals with the fcc structure (normal mechanisms): the accumulation of thermal APBs by means of the intersection of moving dislocations; the formation of APB tubes; the multiplication of superdislocations; the movement of single dislocations; the accumulation of point defects, such as vacancies and interstitial atoms; the accumulation APBs at the climb of edge dislocations. This model takes into account the experimental facts of the wetting antiphase boundaries and emergence of the disordered phase within the ordered phase. The calculations of the creep curves are performed under different conditions. This model describes different kinds of the creep curves and demonstrates the important meaning of the deformation superlocalisation leading to the inverse creep. The experimental and theoretical results coincide rather well.

  3. Angular detector of defects in a metallic tube by eddy currents

    International Nuclear Information System (INIS)

    Broudeur, R.

    1990-01-01

    The angular detector of defects in a metallic tube has two centering pieces for the clad positioning on both sides of a backing ring of the measuring coil. The inner diameter of the backing ring and the diameter of the centering pieces are in the ratio 4/3±0.6/3 and their axis are eccentric. This setting over associated at the guiding piece of the sheath in rotation gives at the measuring coil a functioning as a ponctual probe [fr

  4. Dynamics of spheromak-like compact toroids in a drift tube

    International Nuclear Information System (INIS)

    Suzuki, Y.; Kishimoto, Y.; Hayashi, T.

    2001-01-01

    In order to supply plasma fuel confined in spheromak-like compact toroids (SCTs) to a fusion device, the SCTs must be successfully guided through a drift tube region, in which they might be influenced by the magnetic field leaking from the fusion device. To reveal the SCT dynamics in a drift tube, MHD numerical simulations, where the SCTs are accelerated in a co-axial perfectly conducting cylinder with an external magnetic field, are carried out. In addition, the effect of an extended central electrode is examined by changing the length of the inner conducting cylinder. It is revealed that the SCT penetration depth is shorter than that estimated from the conventional conducting sphere model and that the SCTs are further decelerated by extending the inner conducting cylinder. These results are consistent with the results of the compact toroid injection experiment performed on the TEXT Upgrade tokamak. Finally, the deceleration mechanism of the SCTs is discussed by comparing the simulation result with the proposed theoretical model. (author)

  5. The role of experience curves for setting MEPS for appliances

    International Nuclear Information System (INIS)

    Siderius, Hans-Paul

    2013-01-01

    Minimum efficiency performance standards (MEPS) are an important policy instrument to raise the efficiency of products. In most schemes the concept of life cycle costs (LCC) is used to guide setting the MEPS levels. Although a large body of literature shows that product cost is decreasing with increasing cumulative production, the experience curve, this is currently not used for setting MEPS. This article shows how to integrate the concept of the experience curve into LCC calculations for setting MEPS in the European Union and applies this to household laundry driers, refrigerator-freezers and televisions. The results indicate that for driers and refrigerator-freezers at least twice the energy savings compared to the current approach can be achieved. These products also show that energy label classes can successfully be used for setting MEPS. For televisions an experience curve is provided, showing a learning rate of 29%. However, television prices do not show a relation with energy efficiency but are to a large extent determined by the time the product is placed on the market. This suggests to policy makers that for televisions and other products with a short (re)design and market cycle timing is more important than the MEPS levels itself. - Highlights: • We integrate experience curves into life cycle cost calculations for MEPS. • For driers and refrigerators this results in at least twice the energy savings. • For flat panel televisions an experience curve is provided

  6. The axial crushes behaviour on foam-filled round Jute/Polyester composite tubes

    Science.gov (United States)

    Othman, A.; Ismail, A. E.

    2018-04-01

    The present paper investigates the effect of axial loading compression on jute fibre reinforced polyester composite round tubes. The specimen of composite tube was fabricated by hand lay-up method of 120 mm length with fix 50.8 mm inner diameter to determine the behaviour of energy absorption on number of layers of 450 angle fibre and internally reinforced with and without foam filler material. The foam filler material used in this studies were polyurethane (PU) and polystyrene (PE) with average of 40 and 45 kg/m3 densities on the axial crushing load against displacement relations and on the failure modes. The number of layers of on this study were two; three and four were selected to calculate the crush force efficiency (CFE) and the specific energy absorption (SEA) of the composite tubes. Result indicated that the four layers’ jute/polyester show significant value in term of crushing load compared to 2 and 3 layers higher 60% for 2 layer and 3% compared to 3 layers. It has been found that the specific energy absorption of the jute/polyester tubes with polystyrene foam-filled is found higher respectively 10% to 12% than empty and polyurethane (PU) foam tubes. The increase in the number of layers from two to four increases the mean axial load from 1.01 KN to 3.60 KN for empty jute/polyester and from 2.11 KN to 4.26 KN for the polyurethane (PU) foam-filled jute/polyester tubes as well as for 3.60 KN to 5.58 KN for the polystyrene (PE) foam-filled jute/polyester. The author’s found that the failure of mechanism influence the characteristic of curve load against displacement obtained and conclude that an increasing number of layers and introduce filler material enhance the capability of specific absorbed energy.

  7. Development of safety evaluation technique of steam generator tubes for the next generation

    Energy Technology Data Exchange (ETDEWEB)

    Kwon, Hyuk Sang; Kim, I. S.; Ann, Se Jin; Lee, S. J.; Seo, M. S.; Lee, Y. H.; Kim, J. H.; Hong, J. G. [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    2000-02-15

    Subject 1 - a technique for predicting the SCC susceptibility of steam generator tube material based on the repassivation kinetics was developed and the effects of Pb in the repassivation rate and SCC susceptibility rate of tube material was investigated with this technique. An alloy with a higher slope value of log i(t) vs. q(t) plot based on the current transient curve obtained by scratch test and a lower slope value log i(t) vs. l/q(t) plot (cBV) is repassivated faster with a more protective passive film and it can be predicted that it will show higher resistance to SCC. With PbO addition in all solution studied (pH 4, pH 10, Cl- containing pH 4), alloy 690TT showed decreased repassivation rate. So it can be predict that PbO addition lower the resistance of SCC of steam generator tune material. Subject 2 - SG wear testing of tube and support materials has been conducted at various load and sliding amplitude in air environment. The results showed effect of normal load and sliding amplitude on SG tube wear damage. It was also shown that, for predominantly sliding motion, the SG wear coefficient of work-rate model is lower for Inconel 690TT compared with inconel 600MA. SG tube wear data show that, for work-rates ranging from 4 to 25mW, average tube wear coefficient of 43.76{approx}54.05 X 10{sup 15} Pa{sup -1} for Inconel 600MA and 26.88{approx}33.94 X 10{sup -15} Pa{sup 1} for Inconel 690TT against 405 and 409 stainless steels.

  8. Collaborative Random Faces-Guided Encoders for Pose-Invariant Face Representation Learning.

    Science.gov (United States)

    Shao, Ming; Zhang, Yizhe; Fu, Yun

    2018-04-01

    Learning discriminant face representation for pose-invariant face recognition has been identified as a critical issue in visual learning systems. The challenge lies in the drastic changes of facial appearances between the test face and the registered face. To that end, we propose a high-level feature learning framework called "collaborative random faces (RFs)-guided encoders" toward this problem. The contributions of this paper are three fold. First, we propose a novel supervised autoencoder that is able to capture the high-level identity feature despite of pose variations. Second, we enrich the identity features by replacing the target values of conventional autoencoders with random signals (RFs in this paper), which are unique for each subject under different poses. Third, we further improve the performance of the framework by incorporating deep convolutional neural network facial descriptors and linking discriminative identity features from different RFs for the augmented identity features. Finally, we conduct face identification experiments on Multi-PIE database, and face verification experiments on labeled faces in the wild and YouTube Face databases, where face recognition rate and verification accuracy with Receiver Operating Characteristic curves are rendered. In addition, discussions of model parameters and connections with the existing methods are provided. These experiments demonstrate that our learning system works fairly well on handling pose variations.

  9. Numerical study of effects of the beam tube on laser fields with a three-dimensional simulation code using the finite element method

    CERN Document Server

    Sobajima, M; Yamazaki, T; Yoshikawa, K; Ohnishi, M; Toku, H; Masuda, K; Kitagaki, J; Nakamura, T

    1999-01-01

    In January 1997, the Beijing FEL observed large laser amplification at 8-18 mu m. However, through the collaborative work, it was found from both experiments and numerical simulations that the laser loss on the beam tube wall was not negligible, and that the saturation was not seen in the relatively long wavelength range because of this loss. This calls for further investigation on the effects of the beam tube of finite size. In order to include such effects self-consistently, we have developed a new three-dimensional code that can solve equations with the boundary conditions of the beam tube by using the Finite Element Method. Results show that the beam tube effects are dominant in deriving higher laser modes in the tube, compared with the optical guiding effects, and consequently reduced gain especially in the longer wavelength range, where the beam tube effects are greatly emphasized. It is also found that TEM sub 0 sub 2 mode is the most dominant higher mode in the beam tube, and is also the main cause of...

  10. Helically coiled tube heat exchanger

    International Nuclear Information System (INIS)

    Harris, A.M.

    1981-01-01

    In a heat exchanger such as a steam generator for a nuclear reactor, two or more bundles of helically coiled tubes are arranged in series with the tubes in each bundle integrally continuing through the tube bundles arranged in series therewith. Pitch values for the tubing in any pair of tube bundles, taken transverse to the path of the reactor coolant flow about the tubes, are selected as a ratio of two unequal integers to permit efficient operation of each tube bundle while maintaining the various tube bundles of the heat exchanger within a compact envelope. Preferably, the helix angle and tube pitch parallel to the path of coolant flow are constant for all tubes in a single bundle so that the tubes are of approximately the same length within each bundle

  11. Categorising YouTube

    OpenAIRE

    Simonsen, Thomas Mosebo

    2011-01-01

    This article provides a genre analytical approach to creating a typology of the User Generated Content (UGC) of YouTube. The article investigates the construction of navigation processes on the YouTube website. It suggests a pragmatic genre approach that is expanded through a focus on YouTube’s technological affordances. Through an analysis of the different pragmatic contexts of YouTube, it is argued that a taxonomic understanding of YouTube must be analysed in regards to the vacillation of a...

  12. Experimental and statistical study on fracture boundary of non-irradiated Zircaloy-4 cladding tube under LOCA conditions

    Science.gov (United States)

    Narukawa, Takafumi; Yamaguchi, Akira; Jang, Sunghyon; Amaya, Masaki

    2018-02-01

    For estimating fracture probability of fuel cladding tube under loss-of-coolant accident conditions of light-water-reactors, laboratory-scale integral thermal shock tests were conducted on non-irradiated Zircaloy-4 cladding tube specimens. Then, the obtained binary data with respect to fracture or non-fracture of the cladding tube specimen were analyzed statistically. A method to obtain the fracture probability curve as a function of equivalent cladding reacted (ECR) was proposed using Bayesian inference for generalized linear models: probit, logit, and log-probit models. Then, model selection was performed in terms of physical characteristics and information criteria, a widely applicable information criterion and a widely applicable Bayesian information criterion. As a result, it was clarified that the log-probit model was the best among the three models to estimate the fracture probability in terms of the degree of prediction accuracy for both next data to be obtained and the true model. Using the log-probit model, it was shown that 20% ECR corresponded to a 5% probability level with a 95% confidence of fracture of the cladding tube specimens.

  13. NEI You Tube Videos: Amblyopia

    Medline Plus

    Full Text Available ... YouTube Videos » NEI YouTube Videos: Amblyopia Listen NEI YouTube Videos YouTube Videos Home Age-Related Macular Degeneration ... Retinopathy of Prematurity Science Spanish Videos Webinars NEI YouTube Videos: Amblyopia Embedded video for NEI YouTube Videos: ...

  14. Effect of Tube Pitch on Pool Boiling Heat Transfer of Vertical Tube Bundle

    International Nuclear Information System (INIS)

    Kang, Myeong Gie

    2016-01-01

    Summarizing the previous results it can be stated that heat transfer coefficients are highly dependent on the tube pitch and the heat flux of the relevant tube. The published results are mostly about the horizontal tubes. However, there are many heat exchangers consisting of vertical tubes like AP600. Therefore, the focus of the present study is an identification of the effects of a tube pitch as well as the heat flux of a relevant tube on the heat transfer of a tube bundle installed vertically. When the heat flux is increased many bubbles are generating due to the increase of the nucleation sites. The bubbles become coalescing with the nearby bubbles and generates big bunches of bubbles on the tube surface. This prevents the access of the liquid to the surface and deteriorates heat transfer. The bubble coalescence is competing with the mechanisms enhancing heat transfer. The pitch was varied from 28.5 mm to 95 mm and the heat flux of the nearby tube was changed from 0 to 90kW/m"2. The enhancement of the heat transfer is clearly observed when the heat flux of the nearby tube becomes larger and the heat flux of the upper tube is less than 40kW/m"2. The effect of the tube pitch on heat transfer is negligible as the value of DP/ is increased more than 4.

  15. Effect of heat treatment and composition on stress corrosion cracking of steam generation tubing materials

    International Nuclear Information System (INIS)

    Kim, H. P.; Hwang, S. S.; Kuk, I. H.; Kim, J. S.; Oh, C. Y.

    1998-01-01

    Effects of heat treatment and alloy composition on stress corrosion cracking (SCC) of steam generator tubing materials have been studied in 40% NaOH at 315.deg.C at potential of +200mV above corrosion potential using C-ring specimen and reverse U bend specimen. The tubing materials used were commercial Alloy 600, Alloy 690 and laboratory alloys, Ni-χCr-10Fe. Commercial Alloy 600, Alloy 690 were mill annealed or thermally treated.Laboratory alloy Ni-χCr-10Fe, and some of Alloy 600 and Alloy 690 were solution annealed. Polarization curves were measured to find out any relationship between SCC susceptibility and electrochemical behaviour. The variation in thermal treatment of Alloy 600 and Alloy 690 had no effect on polarization behaviour probably due to small area fraction of carbide and Cr depletion zone near grain boundary. In anodic polarization curves, the first and second anodic peaks at about 170mV and about at 260mV, respectively, above corrosion potential were independent of Cr content, whereas the third peak at 750mV above corrosion potential and passive current density in-creased with Cr content. SCC susceptibility decreased with Cr content and thermal treatment producing semicontinuous grain boundary decoration. Examination of cross sectional area of C-ring specimen showed deep SCC cracks for the alloys with less than 17%Cr and many shallow attacks for alloy 690. The role of Cr content in steam generator tubing materials and grain boundary carbide on SCC were discussed

  16. Optimizing Tube Precurvature to Enhance Elastic Stability of Concentric Tube Robots.

    Science.gov (United States)

    Ha, Junhyoung; Park, Frank C; Dupont, Pierre E

    2017-02-01

    Robotic instruments based on concentric tube technology are well suited to minimally invasive surgery since they are slender, can navigate inside small cavities and can reach around sensitive tissues by taking on shapes of varying curvature. Elastic instabilities can arise, however, when rotating one precurved tube inside another. In contrast to prior work that considered only tubes of piecewise constant precurvature, we allow precurvature to vary along the tube's arc length. Stability conditions for a planar tube pair are derived and used to formulate an optimal design problem. An analytic formulation of the optimal precurvature function is derived that achieves a desired tip orientation range while maximizing stability and respecting bending strain limits. This formulation also includes straight transmission segments at the proximal ends of the tubes. The result, confirmed by both numerical and physical experiment, enables designs with enhanced stability in comparison to designs of constant precurvature.

  17. Assessment of thin-walled cladding tube mechanical properties by segmented expanding Mandrel test

    International Nuclear Information System (INIS)

    Nilsson, Karl-Fredrik

    2015-01-01

    This paper presents the principles of the segmented expanding mandrel test for thin-walled cladding tubes, which can be used as a basic material characterisation test to determine stress-strain curves and ductility or as a test to simulate mechanical pellet-cladding interaction. The paper discusses the strengths and weaknesses of the test method and it illustrates how the test can be used to simulate hydride reorientations in zirconium claddings and quantify how hydride reorientation affects ductility. (authors)

  18. Influence of a glide path on apical extrusion of debris during canal preparation using single-file systems in curved canals.

    Science.gov (United States)

    Topçuoğlu, H S; Düzgün, S; Akpek, F; Topçuoğlu, G; Aktı, A

    2016-06-01

    To evaluate the effect of a glide path on the amount of apically extruded debris during canal preparation using single-file systems in curved canals. Ninety extracted mandibular molar teeth were randomly assigned to six groups (n = 15 for each group) for canal instrumentation. Endodontic access cavities were prepared in each tooth. In three of the six groups, a glide path was not created whereas a glide path was created using PathFile instruments on the mesial canals of all teeth in the remaining three groups. The mesial canals of the teeth were then instrumented with the following single-file instrument systems: WaveOne, Reciproc and OneShape. Debris extruded apically during instrumentation was collected into pre-weighed Eppendorf tubes. The tubes were then stored in an incubator at 70 °C for 5 days. The weight of the dry extruded debris was established by subtracting the pre-instrumentation and post-instrumentation weight of the Eppendorf tubes for each group. The data obtained were analysed using one-way analysis of variance (anova) and Tukey's post hoc tests. The OneShape file was associated with less debris extrusion than the Reciproc and WaveOne files when canal instrumentation was performed without a glide path (P files (P > 0.05). There was no significant difference amongst the OneShape, Reciproc and WaveOne files when a glide path was created before canal preparation in curved root canals (P > 0.05). All systems extruded significantly less debris in groups with a glide path than in groups without a glide path (P < 0.05). All instruments were associated with apical extrusion of debris. Creating a glide path prior to canal instrumentation reduced the amount of apically extruded debris in curved canals. © 2015 International Endodontic Journal. Published by John Wiley & Sons Ltd.

  19. Ageing management of AG3NET beam tubes in ORPHEE Research

    International Nuclear Information System (INIS)

    Florence, Gupta; Maud, Corbel

    2013-01-01

    The materials used in research reactors come from the best compromise between research needs and safety issues such as integrity of equipment during their whole life. For example, aluminium alloys such as AG3NET are interesting for research reactors dedicated to the production of neutron flux since they are transparent to neutrons but they become fragile under irradiation. Therefore the evolution of material's mechanical properties under irradiation is a topic of interest for research reactors safety and operators must implement an ageing management program of equipment subject to irradiation. This kind of aluminium alloys compound is used in many French research reactors like the Jules Horowitz reactor (JHR) and ORPHEE reactor operated by the Atomic Energy and Alternative Energies Commission (CEA) or the high flux reactor (HFR) operated by the Laue-Langevin Institute (ILL). Particularly, in the ORPHEE reactor, AG3NET is used for beam tubes, located in the heavy water tank surrounding the core, which guide neutrons towards experimental stations. The failure of a beam tube in ORPHEE reactor can lead to a reactivity insertion in the core, whose effects can be managed by the control rods system. Nevertheless, to control the effects of ageing on such equipment, the operator plans to replace the beam tubes on the basis of a criterion he defined. For the ORPHEE's second periodic safety review, the operator has re-evaluated the situation of the beam tubes with regard of this criterion and has established a beam tube replacement schedule. The 'Institut de Radioprotection et de Surete Nucleaire' (IRSN), as a technical support of the French nuclear safety authority, assessed the elements presented by the CEA for this periodic safety review and concluded that the replacement criterion used for these equipment lead to reach a fragile behaviour of the materials. Thus, the breaking of several beam tubes can't be excluded but this situation can leads to severe consequences on the

  20. Plasma wave amplitude measurement created by guided laser wakefield

    International Nuclear Information System (INIS)

    Wojda, Franck

    2010-01-01

    The interaction of an intense laser pulse of short duration with a plasma produces a plasma wave with large amplitude in its wake, which is associated with a longitudinal electric field. It can be used to accelerate relativistic electrons injected into the wave to energies in the GeV range over distances of the order of a few centimeters, short compared to acceleration lengths in conventional accelerators. The control of the electron beam characteristics during the acceleration process is fundamental for achieving a usable laser-plasma acceleration stage. The main result of this thesis is the creation and characterization of a plasma wave in a weakly nonlinear regime over a length of several centimeters. Capillary tubes are used to guide the laser beam over these distances, while maintaining a large enough intensity (∼ 10 17 W/cm 2 ). The guided laser beam ionizes the gas in the tube and creates the plasma wave. A diagnostic based on the modification of the laser pulse spectrum was used to determine the amplitude of the plasma wave along the tube. The amplitude of the plasma wave was studied as a function of gas filling pressure, length of the capillary and laser energy. Experimental results are compared; they are in excellent agreement with analytical results and modeling. They show that the electric field associated with the plasma wave is between 1 and 10 GV/m over a length of up to 8 cm. This work has demonstrated the ability to create a controlled plasma wave in a weakly nonlinear regime. (author)

  1. CT-guided stereotactic evacuation of hypertensive intracerebral hematomas

    International Nuclear Information System (INIS)

    Hondo, Hideki

    1983-01-01

    Computerized tomography (CT) is now effective not only for definite diagnosis and location of intracerebral hematomas but also for coordination of the center of a hematoma. CT-guided stereotactic evacuation of hypertensive intracerebral hematoma was performed in 51 cases: 34 of basal ganglionic hematoma with or without ventricular perforation, 11 of subcortical hematoma, 3 of thalamic hematoma and 3 of cerebellar hematoma. Three dimensional CT images or biplane CT images were taken to determine the coordinates of the target point, which was the center of the hematoma. Then, a silicon tube (O.D. 3.5 phi, I.D. 2.1 phi) was inserted into the center of the hematoma through a burr-hole under local anesthesia, and the liquid or solid hematoma was aspirated as completely as possible with a syringe. Urokinase (6,000 I.U./5 ml saline) was administered through this silicon tube every 6 or 12 hours for several days until the hematoma had drained out competely. The silicon tube was taken out when repeated CT scanning revealed no hematoma. The results of clinical follow-ups indicated that this procedure is as good as, or rather better than conventional microsurgery with evacuation of hematoma under direct vision. Moreover this CT-guided stereotactic approach for evacuation of the hematoma has the following advantages: 1) the procedure is simple and safe, 2) operation can be performed under local anesthesia, and 3) the hematoma is drained out completely with the aid of urokinase. This surgery seems indicated as an emergency treatment for high-age or high risk patients and also as a routine surgery for intracerebral hematomas in patients showing no herination signs. (author)

  2. Automation in tube finishing bay

    International Nuclear Information System (INIS)

    Bhatnagar, Prateek; Satyadev, B.; Raghuraman, S.; Syama Sundara Rao, B.

    1997-01-01

    Automation concept in tube finishing bay, introduced after the final pass annealing of PHWR tubes resulted in integration of number of sub-systems in synchronisation with each other to produce final cut fuel tubes of specified length, tube finish etc. The tube finishing bay which was physically segregated into four distinct areas: 1. tube spreader and stacking area, 2. I.D. sand blasting area, 3. end conditioning, wad blowing, end capping and O.D. wet grinding area, 4. tube inspection, tube cutting and stacking area has been studied

  3. CRL X-ray tube

    International Nuclear Information System (INIS)

    Kolchevsky, N.N.; Petrov, P.V.

    2015-01-01

    A novel types of X-ray tubes with refractive lenses are proposed. CRL-R X-ray tube consists of Compound Refractive Lens- CRL and Reflection X-ray tube. CRL acts as X-ray window. CRL-T X-ray consists of CRL and Transmission X-ray tube. CRL acts as target for electron beam. CRL refractive lens acts as filter, collimator, waveguide and focusing lens. Properties and construction of the CRL X-ray tube are discussed. (authors)

  4. A flow test for calibrating 177 core tubes of 1/5-scale reactor flow model for Yonggwang nuclear units 3 and 4

    International Nuclear Information System (INIS)

    Lee, Byung Jin; Jang, Ho Cheol; Cheong, Jong Sik; Kuh, Jung Eui

    1990-01-01

    A flow test was performed to find out the hydraulic characteristics of every one of 177 core tubes, representing a fuel assembly respectively, as a preparatory step of 1/5 scale reactor flow model test for Yonggwang Nuclear Units (hereafter YGN) 3 and 4. The axial hydraulic resistance of the fuel assembly was simulated in the square core tube with six orifice plates positioned along the tube length; core support structure below each fuel assembly was done in the core upstream geometry section of the test loop. For each core tube the pressure differentials across the inlet, exit orifice plate and overall tube length were measured, along with the flow rates and temperatures of the test fluid. The measured pressure drops were converted to pressure loss or flow metering coefficients. The metering coefficient of the inlet orifice plate was sensitive to the configuration and location of the upstream geometry. The hydraulic resistance of the core tubes were reasonably coincided with a target value and consistent. The polynomial curve fits of the calibrated coefficients for the 177 core tubes were obtained with reasonable data scatters

  5. Pediatric cuffed endotracheal tubes

    Directory of Open Access Journals (Sweden)

    Neerja Bhardwaj

    2013-01-01

    Full Text Available Endotracheal intubation in children is usually performed utilizing uncuffed endotracheal tubes for conduct of anesthesia as well as for prolonged ventilation in critical care units. However, uncuffed tubes may require multiple changes to avoid excessive air leak, with subsequent environmental pollution making the technique uneconomical. In addition, monitoring of ventilatory parameters, exhaled volumes, and end-expiratory gases may be unreliable. All these problems can be avoided by use of cuffed endotracheal tubes. Besides, cuffed endotracheal tubes may be of advantage in special situations like laparoscopic surgery and in surgical conditions at risk of aspiration. Magnetic resonance imaging (MRI scans in children have found the narrowest portion of larynx at rima glottides. Cuffed endotracheal tubes, therefore, will form a complete seal with low cuff pressure of <15 cm H 2 O without any increase in airway complications. Till recently, the use of cuffed endotracheal tubes was limited by variations in the tube design marketed by different manufacturers. The introduction of a new cuffed endotracheal tube in the market with improved tracheal sealing characteristics may encourage increased safe use of these tubes in clinical practice. A literature search using search words "cuffed endotracheal tube" and "children" from 1980 to January 2012 in PUBMED was conducted. Based on the search, the advantages and potential benefits of cuffed ETT are reviewed in this article.

  6. Theory of the development of curved barbs and their effects on feather morphology.

    Science.gov (United States)

    Feo, Teresa J; Simon, Emma; Prum, Richard O

    2016-08-01

    Feathers exhibit an extraordinary diversity of shapes, which are used by birds to accomplish a diverse set of functions. Pennaceous feathers have a double branched morphology that develops from a tube of epidermis, and variation in branch geometry determines feather shape. Feather development is both complex (i.e., a simple developmental modification can have multiple effects on mature feather shape), and redundant (i.e., different developmental modifications can create the same shape). Due to this, it is not readily apparent how different feather shapes develop. In many feathers, barbs are not straight, but instead curve in toward, or away, from the feather tip. Barb curvature can affect the shape of mature feathers but the development of curved barbs is unknown. Previous research has hypothesized that barb curvature could develop either during the helical growth of barb ridges in the tubular feather germ, or during barb angle expansion as the feather unfurls from the sheath. To better understand the development of curved barbs and their effects on mature feathers we present a theoretical model of curved barb development and test the model with empirical investigations of feathers. We find that curved barbs affect many aspects of feather morphology including vane width, barb length, and barb spacing. In real feathers, curved barbs can develop both during helical barb ridge growth and during barb angle expansion, with most of the observed curvature due to barb angle expansion. Our results demonstrate that barb angle expansion as a feather unfurls from the sheath is a complex and dynamic process that plays an important role in determining the shape and structure of mature feathers. Curved barbs create heterogeneity in barb geometry within the feather vane, which could have important implications for aerodynamic function and the development of within feather pigmentation patterns. J. Morphol. 277:995-1013, 2016. © 2016 Wiley Periodicals, Inc. © 2016 Wiley

  7. Panel 2: Anatomy (Eustachian Tube, Middle Ear, and Mastoid-Anatomy, Physiology, Pathophysiology, and Pathogenesis).

    Science.gov (United States)

    Alper, Cuneyt M; Luntz, Michal; Takahashi, Haruo; Ghadiali, Samir N; Swarts, J Douglas; Teixeira, Miriam S; Csákányi, Zsuzsanna; Yehudai, Noam; Kania, Romain; Poe, Dennis S

    2017-04-01

    Objective In this report, we review the recent literature (ie, past 4 years) to identify advances in our understanding of the middle ear-mastoid-eustachian tube system. We use this review to determine whether the short-term goals elaborated in the last report were achieved, and we propose updated goals to guide future otitis media research. Data Sources PubMed, Web of Science, Medline. Review Methods The panel topic was subdivided, and each contributor performed a literature search within the given time frame. The keywords searched included middle ear, eustachian tube, and mastoid for their intersection with anatomy, physiology, pathophysiology, and pathology. Preliminary reports from each panel member were consolidated and discussed when the panel met on June 11, 2015. At that meeting, the progress was evaluated and new short-term goals proposed. Conclusions Progress was made on 13 of the 20 short-term goals proposed in 2011. Significant advances were made in the characterization of middle ear gas exchange pathways, modeling eustachian tube function, and preliminary testing of treatments for eustachian tube dysfunction. Implications for Practice In the future, imaging technologies should be developed to noninvasively assess middle ear/eustachian tube structure and physiology with respect to their role in otitis media pathogenesis. The new data derived from these structure/function experiments should be integrated into computational models that can then be used to develop specific hypotheses concerning otitis media pathogenesis and persistence. Finally, rigorous studies on medical or surgical treatments for eustachian tube dysfunction should be undertaken.

  8. Pressure tube type research reactor

    International Nuclear Information System (INIS)

    Ueda, Hiroshi.

    1976-01-01

    Object: To prevent excessive heat generation due to radiation of a pressure tube vessel. Structure: A pressure tube encasing therein a core comprises a dual construction comprising inner and outer tubes coaxially disposed. High speed cooling water is passed through the inner tube for cooling. In addition, in the outer periphery of said outer tube there is provided a forced cooling tube disposed coaxially thereto, into which cooling fluid, for example, such as moderator or reflector is forcibly passed. This forced cooling tube has its outer periphery surrounded by the vessel into which moderator or reflector is fed. By the provision of the dual construction of the pressure tube and the forced cooling tube, the vessel may be prevented from heat generation. (Ikeda, J.)

  9. Deep Convolutional Neural Networks for Endotracheal Tube Position and X-ray Image Classification: Challenges and Opportunities.

    Science.gov (United States)

    Lakhani, Paras

    2017-08-01

    The goal of this study is to evaluate the efficacy of deep convolutional neural networks (DCNNs) in differentiating subtle, intermediate, and more obvious image differences in radiography. Three different datasets were created, which included presence/absence of the endotracheal (ET) tube (n = 300), low/normal position of the ET tube (n = 300), and chest/abdominal radiographs (n = 120). The datasets were split into training, validation, and test. Both untrained and pre-trained deep neural networks were employed, including AlexNet and GoogLeNet classifiers, using the Caffe framework. Data augmentation was performed for the presence/absence and low/normal ET tube datasets. Receiver operating characteristic (ROC), area under the curves (AUC), and 95% confidence intervals were calculated. Statistical differences of the AUCs were determined using a non-parametric approach. The pre-trained AlexNet and GoogLeNet classifiers had perfect accuracy (AUC 1.00) in differentiating chest vs. abdominal radiographs, using only 45 training cases. For more difficult datasets, including the presence/absence and low/normal position endotracheal tubes, more training cases, pre-trained networks, and data-augmentation approaches were helpful to increase accuracy. The best-performing network for classifying presence vs. absence of an ET tube was still very accurate with an AUC of 0.99. However, for the most difficult dataset, such as low vs. normal position of the endotracheal tube, DCNNs did not perform as well, but achieved a reasonable AUC of 0.81.

  10. Flash photolysis-shock tube studies

    Energy Technology Data Exchange (ETDEWEB)

    Michael, J.V. [Argonne National Laboratory, IL (United States)

    1993-12-01

    Even though this project in the past has concentrated on the measurement of thermal bimolecular reactions of atomic species with stable molecules by the flash or laser photolysis-shock tube (FP- or LP-ST) method using atomic resonance absorption spectrometry (ARAS) as the diagnostic technique, during the past year the authors have concentrated on studies of the thermal decompositions of selected chlorocarbon molecules. These studies are necessary if the degradation of chlorine containing organic molecules by incineration are to be understood at the molecular level. Clearly, destruction of these molecules will not only involve abstraction reactions, when possible, but also thermal decomposition followed by secondary reactions of the initially formed atoms and radicals. Studies on the thermal decomposition of CH{sub 3}Cl are complete, and the curve-of-growth for Cl-atom atomic resonance absorption has been determined. The new thermal decomposition studies are similar to those already reported for CH{sub 3}Cl.

  11. Streak tube development

    International Nuclear Information System (INIS)

    Hinrichs, C.K.; Estrella, R.M.

    1979-01-01

    A research program for the development of a high-speed, high-resolution streak image tube is described. This is one task in the development of a streak camera system with digital electronic readout, whose primary application is for diagnostics in underground nuclear testing. This program is concerned with the development of a high-resolution streak image tube compatible with x-ray input and electronic digital output. The tube must be capable of time resolution down to 100 psec and spatial resolution to provide greater than 1000 resolution elements across the cathode (much greater than presently available). Another objective is to develop the capability to make design changes in tube configurations to meet different experimental requirements. A demountable prototype streak tube was constructed, mounted on an optical bench, and placed in a vacuum system. Initial measurements of the tube resolution with an undeflected image show a resolution of 32 line pairs per millimeter over a cathode diameter of one inch, which is consistent with the predictions of the computer simulations. With the initial set of unoptmized deflection plates, the resolution pattern appeared to remain unchanged for static deflections of +- 1/2-inch, a total streak length of one inch, also consistent with the computer simulations. A passively mode-locked frequency-doubled dye laser is being developed as an ultraviolet pulsed light source to measure dynamic tube resolution during streaking. A sweep circuit to provide the deflection voltage in the prototype tube has been designed and constructed and provides a relatively linear ramp voltage with ramp durations adjustable between 10 and 1000 nsec

  12. Technique employed to seal a tube leaking in a heat exchanger of the tube type by explosives with supporting means for the adjacent tubes

    International Nuclear Information System (INIS)

    Larson, G.C.

    1978-01-01

    This invention concerns the technique employed to seal a tube leaking in a heat exchanger of the tube and tube plate type by detonating metal plugs activated by an explosive and inserted in both ends of the tube. It refers in particular to an apparatus and process in which the deformation or distortion of the adjacent tubes and tube plate ties under the effect of the explosive forces is significantly reduced [fr

  13. Assessment of the French and US embrittlement trend curves applied to RPV materials irradiated in the BR2 materials test reactor

    International Nuclear Information System (INIS)

    Chaouadi, R.; Gerard, R.; Boagaerts, A.S.

    2011-01-01

    The irradiation embrittlement of reactor pressure vessels (RPVs) in monitored through the surveillance programs associated with predictive formulas, the so-called embrittlement trend curves. These formulas are generally empirically derived and contain the major embrittlement-inducing elements such as copper, nickel and phosphorus. There are a number of such trend curves used in various regulatory guides used in the US, France, Germany, Russia and Japan. These trend curves are often supported by surveillance data and regularly assessed in view of updated surveillance databases. With the recent worldwide move towards life extension of existing reactors above their initially-scheduled lifetime of 40 years, adequate and accurate modeling of irradiation embrittlement becomes a concern for long term operation. The aim of this work is to assess the performance of the embrittlement trend curves used in a regulatory perspective. The work presented here is limited to US and French trend curves because the reactor pressure vessels of the Belgian nuclear power plants are either Westinghouse or Framatome design. The chemical composition of the Belgian RPVs being very close to the one of the French 900 MW units, the French trend curve is used except for the Doel 1-2 units for which these curves are not applicable due to the higher copper content of the welds. In this case, the U.S. trend curves are used. The aim of this work is to evaluate the performance of the embrittlement trend curves used in a regulatory perspective to represent the experimental data obtained in the BR2 reactor. In particular, the French (FIM, FIS) and the US (Reg. Guide 1.99 Rev. 2, ASTM E900-02, EWO and EONY) formulas are of prime interest. The results obtained clearly show that the French trend curves tend to over-estimate the actual irradiation hardening while the US curves under-estimate it. Within the long term operation perspective, both over- and under-estimating are undesirable and therefore the

  14. Numerical study of pressure fluctuations in different guide vanes' opening angle in pump mode of a pump turbine

    International Nuclear Information System (INIS)

    Sun, Y K; Zuo, Z G; Liu, S H; Wu, Y L; Liu, J T

    2012-01-01

    A numerical model based on a pumped storage power station was built to develop the numerical simulation, to analyze the pressure fluctuations in a pump turbine in different guide vanes' opening angle. The different guide vanes' opening angles were simulated using the SST k-ω turbulence model and SIMPLEC Pressure-Velocity coupling scheme. The pressure sensor were placed in mainly three positions, they are: bottom ring between runner and the wicket gates, downstream and left side in the draft tube cone below the runner. All the peak to peak values of pressure fluctuation meet signal probability of 97%. The frequency is gained by Fast Fourier Transform. The pressure fluctuations in different positions of the model in pump condition were showed when the guide vanes' opening angels were different. The simulation results confirmed the results gained in model tests. The results show that pressure fluctuations in design opening angle were much lower than those in off design opening angle. The main source of pressure fluctuations between runner and guide vanes is rotor stator interaction. While a lower frequency is the main frequency of the pressure fluctuation in draft tube.

  15. Effect of Localizer Radiography Projection on Organ Dose at Chest CT with Automatic Tube Current Modulation.

    Science.gov (United States)

    Saltybaeva, Natalia; Krauss, Andreas; Alkadhi, Hatem

    2017-03-01

    Purpose To calculate the effect of localizer radiography projections to the total radiation dose, including both the dose from localizer radiography and that from subsequent chest computed tomography (CT) with tube current modulation (TCM). Materials and Methods An anthropomorphic phantom was scanned with 192-section CT without and with differently sized breast attachments. Chest CT with TCM was performed after one localizer radiographic examination with anteroposterior (AP) or posteroanterior (PA) projections. Dose distributions were obtained by means of Monte Carlo simulations based on acquired CT data. For Monte Carlo simulations of localizer radiography, the tube position was fixed at 0° and 180°; for chest CT, a spiral trajectory with TCM was used. The effect of tube start angles on dose distribution was investigated with Monte Carlo simulations by using TCM curves with fixed start angles (0°, 90°, and 180°). Total doses for lungs, heart, and breast were calculated as the sum of the dose from localizer radiography and CT. Image noise was defined as the standard deviation of attenuation measured in 14 circular regions of interest. The Wilcoxon signed rank test, paired t test, and Friedman analysis of variance were conducted to evaluate differences in noise, TCM curves, and organ doses, respectively. Results Organ doses from localizer radiography were lower when using a PA instead of an AP projection (P = .005). The use of a PA projection resulted in higher TCM values for chest CT (P chest CT. © RSNA, 2016 Online supplemental material is available for this article.

  16. Steam generator tube performance

    International Nuclear Information System (INIS)

    Tatone, O.S.; Pathania, R.S.

    1983-08-01

    A review of the performance of steam generator tubes in 110 water-cooled nuclear power reactors showed that tubes were plugged at 46 (42 percent) of the reactors. The number of tubes removed from service increased from 1900 (0.14 percent) in 1980 to 4692 (0.30 percent) in 1981. The leading causes of tube failures were stress corrosion cracking from the primary side, stress corrosion cracking (or intergranular attack) from the secondary side and pitting corrosion. The lowest incidence of corrosion-induced defects from the secondary side occurred in reactors that used all-volatile treatment since start-up. At one reactor a large number of degraded tubes were repaired by sleeving which is expected to become an important method of tube repair in the future

  17. Study on antioxidant experiment on forged steel tube sheet and tube hole for steam generator

    International Nuclear Information System (INIS)

    Zong Hai; Wang Detai; Ding Yang

    2012-01-01

    Antioxidant experiment on forged steel tube sheet and tube hole for steam generator was studied and the influence of different simulated heat treatments on the antioxidant performance of tube sheet and tube hole was made. The influence of different antioxidant methods on the size of tube hole was drawn. Furthermore, the change of size and weight of 18MnD5 forged steel tube sheet on the condition of different simulated heat treatments was also studied. The analytical results have proved reference information for the use of 18MnD5 material and for key processes of processing tube hole and wearing and expanding U-style tube. (authors)

  18. Ultrasound-Guided Bipolar Umbilical Cord Occlusion in Complicated Monochorionic Pregnancies

    DEFF Research Database (Denmark)

    Schou, Katrine V; Jensen, Lisa N; Jørgensen, Connie

    2017-01-01

    INTRODUCTION: Ultrasound-guided bipolar umbilical cord occlusion (UCO) is used in complicated monochorionic multiple pregnancies in Denmark. The aim of this study was to assess a learning curve in the procedure of UCO. MATERIALS AND METHODS: One hundred and two monochorionic pregnancies treated...

  19. Probe train including a flaw detector and a radiation responsive recording means with alignment means having a natural curved cast

    International Nuclear Information System (INIS)

    Stone, R.M.

    1975-01-01

    An inspection system for a multitube steam generator comprising a probe train for insertion in a tube to be inspected is described. The probe train includes, in series, directional probe means, such as an eddy current probe, for indicating the longitudinal and angular location of an irregularity at or in the wall of the tube, and radiation responsive recording means nonrotatable relative to the eddy current probe during operation and in substantially close longitudinal relationship thereto for receiving an image of the irregularity when laterally adjacent thereto; elongated alignment means joined to at least one end of the probe train against rotation relative thereto and insertable in the tube for controlling or determining the angular orientation of the probe train within the tube; means for propelling the probe train longitudinally within the tube; and a source of radiation insertable in another tube of the steam generator to a position therealong laterally adjacent the indicated irregularity for irradiation of the irregularity to project said image on the recording means. The directional probe means may preferably be an eddy current probe and the radiation responsive recording means may preferably be a film bearing cassette probe. The alignment means may be provided by a resilient naturally curved plastic cable, which cable might also be used to propel the probe train. (auth)

  20. Heat exchanger with layers of helical tubes provided with improved tube supports

    International Nuclear Information System (INIS)

    Carnoy, M.; Mathieu, B.; Renaux, C.

    1986-01-01

    The present heat exchanger comprises coaxial layers of helically wound tubes; these tubes are supported by support plates, each comprising a row of perforations through which the tubes of a same layer pass. Truncated sleeves are in compression around the tubes within the perforations and mounted on the support plates. Pins fix the plates of different layers together against transverse movement but allowing radial movement. The present invention finds an application with nuclear reactor steam generators [fr

  1. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    International Nuclear Information System (INIS)

    Welch, B. T.; Eiken, P. W.; Atwell, T. D.; Peikert, T.; Yi, E. S.; Nichols, F.; Schmit, G. D.

    2017-01-01

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  2. A Single-Institution Experience in Percutaneous Image-Guided Biopsy of Malignant Pleural Mesothelioma

    Energy Technology Data Exchange (ETDEWEB)

    Welch, B. T., E-mail: Welch.brian@mayo.edu; Eiken, P. W.; Atwell, T. D. [Mayo Clinic, Department of Radiology (United States); Peikert, T. [Mayo Clinic, Department of Pulmonary and Critical Care Medicine (United States); Yi, E. S. [Mayo Clinic, Department of Pathology (United States); Nichols, F. [Mayo Clinic, Department of Thoracic Surgery (United States); Schmit, G. D. [Mayo Clinic, Department of Radiology (United States)

    2017-06-15

    PurposeMesothelioma has been considered a difficult pathologic diagnosis to achieve via image-guided core needle biopsy. The purpose of this study was to assess the diagnostic sensitivity of percutaneous image-guided biopsy for diagnosis of pleural mesothelioma.Materials and MethodsRetrospective review was performed to identify patients with a confirmed diagnosis of pleural mesothelioma and who underwent image-guided needle biopsy between January 1, 2002, and January 1, 2016. Thirty-two patients with pleural mesothelioma were identified and included for analysis in 33 image-guided biopsy procedures. Patient, procedural, and pathologic characteristics were recorded. Complications were characterized via standardized nomenclature [Common Terminology for Clinically Adverse Events (CTCAE)].ResultsPercutaneous image-guided biopsy was associated with an overall sensitivity of 81%. No CTCAE clinically significant complications were observed. No image-guided procedures were complicated by pneumothorax or necessitated chest tube placement. No patients had tumor seeding of the biopsy tract.ConclusionPercutaneous image-guided biopsy can achieve high sensitivity for pathologic diagnosis of pleural mesothelioma with a low procedural complication rate, potentially obviating need for surgical biopsy.

  3. An in-tube radar for detecting cracks in metal tubing

    International Nuclear Information System (INIS)

    Caffey, Thurlow W. H.; Nassersharif, Bahram; Garcia, Gabe V.; Smith, Phillip R.; Jedlicka, Russell P.; Hensel, Edward C.

    2000-01-01

    A major cause of failures in heat exchangers and steam generators in nuclear power plants is degradation of the tubes within them. The tube failure is often caused by the development of cracks that begin on the outer surface of the tube and propagate both inwards and laterally. A new technique will be described for detection of defects using a continuous-wave radar device within metal tubing. The technique is 100% volumetric, and may find smaller defects, find them more rapidly, and find them less expensively than present methods. Because this project was started only recently, there is no demonstrated performance to report so far. However, the basic engineering concepts will be presented together with a description of the milestone tasks and dates

  4. Literature review on risky driving videos on YouTube: Unknown effects and areas for concern?

    Science.gov (United States)

    Vingilis, Evelyn; Yıldırım-Yenier, Zümrüt; Vingilis-Jaremko, Larissa; Wickens, Christine; Seeley, Jane; Fleiter, Judy; Grushka, Daniel H

    2017-08-18

    Entry of terms reflective of extreme risky driving behaviors into the YouTube website yields millions of videos. The majority of the top 20 highly subscribed automotive YouTube websites are focused on high-performance vehicles, high speed, and often risky driving. Moreover, young men are the heaviest users of online video sharing sites, overall streaming more videos, and watching them longer than any other group. The purpose of this article is to review the literature on YouTube videos and risky driving. A systematic search was performed using the following specialized database sources-Scopus, PubMed, Web of Science, ERIC, and Google Scholar-for the years 2005-2015 for articles in the English language. Search words included "YouTube AND driving," "YouTube AND speeding," "YouTube AND racing." No published research was found on the content of risky driving videos or on the effects of these videos on viewers. This literature review presents the current state of our published knowledge on the topic, which includes a review of the effects of mass media on risky driving cognitions; attitudes and behavior; similarities and differences between mass and social media; information on the YouTube platform; psychological theories that could support YouTube's potential effects on driving behavior; and 2 examples of risky driving behaviors ("sidewalk skiing" and "ghost riding the whip") suggestive of varying levels of modeling behavior in subsequent YouTube videos. Every month about 1 billion individuals are reported to view YouTube videos (ebizMBA Guide 2015 ) and young men are the heaviest users, overall streaming more YouTube videos and watching them longer than women and other age groups (Nielsen 2011 ). This group is also the most dangerous group in traffic, engaging in more per capita violations and experiencing more per capita injuries and fatalities (e.g., Parker et al. 1995 ; Reason et al. 1990 ; Transport Canada 2015 ; World Health Organization 2015 ). YouTube also

  5. Expansion lyre-shaped tube

    International Nuclear Information System (INIS)

    Andro, Jean.

    1973-01-01

    The invention relates the expansion lyre-shaped tube portions formed in dudgeoned tubular bundles between two bottom plates. An expansion lyre comprises at least two sets of tubes of unequal lengths coplanar and symmetrical with respect to the main tube axis, with connecting portions between the tubes forming said sets. The invention applies to apparatus such as heat exchangers, heaters, superheaters or breeders [fr

  6. Evaluation of Morphological and Functional Nerve Recovery of Rat Sciatic Nerve with a Hyaff11-Based Nerve Guide

    Directory of Open Access Journals (Sweden)

    K. Jansen

    2006-01-01

    Full Text Available Application of a Hyaff11-based nerve guide was studied in rats. Functional tests were performed to study motor nerve recovery. A withdrawal reflex test was performed to test sensory recovery. Morphology was studied by means of histology on explanted tissue samples. Motor nerve recovery was established within 7 weeks. Hereafter, some behavioral parameters like alternating steps showed an increase in occurence, while others remained stable. Sensory function was observed within the 7 weeks time frame. Nerve tissue had bridged the 10-mm gap within 7 weeks. The average nerve fiber surface area increased significantly in time. In situ degradation of the nerve conduit was fully going on at week 7 and tubes had collapsed by then. At weeks 15 and 21, the knitted tube wall structure was completely surrounded by macrophages and giant cells, and matrix was penetrating the tube wall. We conclude that a Hyaff11-based nerve guide can be used to bridge short peripheral nerve defects in rat. However, adaptations need to be made.

  7. Steam generator tube failures

    International Nuclear Information System (INIS)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service

  8. Prospects for stronger calandria tubes

    International Nuclear Information System (INIS)

    Ells, C.E.; Coleman, C.E.; Hosbons, R.R.; Ibrahim, E.F.; Doubt, G.L.

    1990-12-01

    The CANDU calandria tubes, made of seam welded and annealed Zircaloy-2, have given exemplary service in-reactor. Although not designed as a system pressure containment, calandria tubes may remain intact even in the face of pressure tube rupture. One such incident at Pickering Unit 2 demonstrated the economic advantage of such an outcome, and a case can be made for increasing the probability that other calandria tubes would perform in a similar fashion. Various methods of obtaining stronger calandria tubes are available, and reviewed here. When the tubes are internally pressurized, the weld is the weak section of the tube. Increasing the oxygen concentration in the starting sheet, and thickening the weld, are promising routes to a stronger tube

  9. Fiber Bragg gratings-based sensing for real-time needle tracking during MR-guided brachytherapy

    NARCIS (Netherlands)

    Borot, Maxence; Denis de Senneville, Baudouin; Maenhout, Metha; Lagendijk, JJW; van Vulpen, Marco; Hautvast, Gilion; Binnekamp, Dirk; Moerland, Rien

    2016-01-01

    PURPOSE: The development of MR-guided high dose rate (HDR) brachytherapy is under investigation due to the excellent tumor and organs at risk visualization of MRI. However, MR-based localization of needles (including catheters or tubes) has inherently a low update rate and the required image

  10. Pressure tube reactor

    International Nuclear Information System (INIS)

    Kanazawa, Nobuhiro; Kaneto, Kunikazu.

    1979-01-01

    Purpose: To attain uniform fluid poison distribution in a calandria tank by downwardly projecting, at an equal distance to the reactor core, a spacer wall from the periphery of an anti-vibration plate in the vicinity of a heavy water flow passage in the periphery of the anti-vibration plate, thereby decrease the amount of heavy water flowing into the heavy water flow passage. Constitution: A projecting wall concentrical with a calandria tank is suspended vertically from the boundary side at the peripheral portion of an anti-vibration plate to a water heavy flow passage in the periphery of the anti-vibration plate. The projecting wall has such a vertical length as about equal to the width of the heavy water flow passage, prevents heavy water flowing through apertures of a control rod guide tube from entering into the heavy water passage and increases the ratio of heavy water that flows through the heavy water flow passage in the anti-vibration plate. Consequently, if the liquid poison density in heavy water is varied, the ununiform poison density in the calandria tank can be prevented. (Seki, T.)

  11. Method for shaping polyethylene tubing

    Science.gov (United States)

    Kramer, R. C.

    1981-01-01

    Method forms polyethylene plastic tubing into configurations previously only possible with metal tubing. By using polyethylene in place of copper or stain less steel tubing inlow pressure systems, fabrication costs are significantly reduced. Polyethylene tubing can be used whenever low pressure tubing is needed in oil operations, aircraft and space applications, powerplants, and testing laboratories.

  12. Spring/dimple instrument tube restraint

    International Nuclear Information System (INIS)

    DeMario, E.E.; Lawson, C.N.

    1993-01-01

    A nuclear fuel assembly for a pressurized water nuclear reactor has a spring and dimple structure formed in a non-radioactive insert tube placed in the top of a sensor receiving instrumentation tube thimble disposed in the fuel assembly and attached at a top nozzle, a bottom nozzle, and intermediate grids. The instrumentation tube thimble is open at the top, where the sensor or its connection extends through the cooling water for coupling to a sensor signal processor. The spring and dimple insert tube is mounted within the instrumentation tube thimble and extends downwardly adjacent the top. The springs and dimples restrain the sensor and its connections against lateral displacement causing impact with the instrumentation tube thimble due to the strong axial flow of cooling water. The instrumentation tube has a stainless steel outer sleeve and a zirconium alloy inner sleeve below the insert tube adjacent the top. The insert tube is relatively non-radioactivated inconel alloy. The opposed springs and dimples are formed on diametrically opposite inner walls of the insert tube, the springs being formed as spaced axial cuts in the insert tube, with a web of the insert tube between the cuts bowed radially inwardly for forming the spring, and the dimples being formed as radially inward protrusions opposed to the springs. 7 figures

  13. Illumination of interior spaces by bended hollow light guides: Application of the theoretical light propagation method

    Energy Technology Data Exchange (ETDEWEB)

    Darula, Stanislav; Kocifaj, Miroslav; Kittler, Richard [ICA, Slovak Academy of Sciences, Bratislava (Slovakia); Kundracik, Frantisek [Department of Experimental Physics, FMPI, Comenius University, Bratislava (Slovakia)

    2010-12-15

    To ensure comfort and healthy conditions in interior spaces the thermal, acoustics and daylight factors of the environment have to be considered in the building design. Due to effective energy performance in buildings the new technology and applications also in daylight engineering are sought such as tubular light guides. These allow the transport of natural light into the building core reducing energy consumption. A lot of installations with various geometrical and optical properties can be applied in real buildings. The simplest set of tubular light guide consists of a transparent cupola, direct tube with high reflected inner surface and a ceiling cover or diffuser redistributing light into the interior. Such vertical tubular guide is often used on flat roofs. When the roof construction is inclined a bend in the light guide system has to be installed. In this case the cupola is set on the sloped roof which collects sunlight and skylight from the seen part of the sky hemisphere as well as that reflected from the ground and opposite facades. In comparison with the vertical tube some additional light losses and distortions of the propagated light have to be expected in bended tubular light guides. Recently the theoretical model of light propagation was already published and its applications are presented in this study solving illuminance distributions on the ceiling cover interface and further illuminance distribution on the working plane in the interior. (author)

  14. Intercostal drainage tube or intracardiac drainage tube?

    Science.gov (United States)

    Anitha, N; Kamath, S Ganesh; Khymdeit, Edison; Prabhu, Manjunath

    2016-01-01

    Although insertion of chest drain tubes is a common medical practice, there are risks associated with this procedure, especially when inexperienced physicians perform it. Wrong insertion of the tube has been known to cause morbidity and occasional mortality. We report a case where the left ventricle was accidentally punctured leading to near-exsanguination. This report is to highlight the need for experienced physicians to supervise the procedure and train the younger physician in the safe performance of the procedure.

  15. Demonstration and evaluation of solid state photomultiplier tube for uranium exploration instrumentation. National uranium resources evaluation. Final report

    International Nuclear Information System (INIS)

    Polichar, R.M.

    1982-06-01

    The purpose of this program has been to evaluate the recently developed solid state photomultiplier tube (SSPMT) technology as a potential improvment to future uranium exploration instrumentation. To this end, six SSPMTs have been constructed and evaluated in a manner similar to that of conventional phototubes. Special regard has been placed on the measurement of pulse height resolution and the factors that affect it in tube design and manufacture. The tubes were subjected to a number of tests similar to those performed on conventional photomultiplier tubes. The results indicate that good, high-resolution spectra can be obtained from the tubes and that they behave generally in a predictable manner. They exhibited a linear gain increase with applied potential. They show only slight dependence of performance with applied potential. Their sensitivity is, for the most part, uniform and predictable. However, several characteristics were found that were not predictable. These include a general drop in measured quantum efficiency, a worsening resolution with operation, and a bump in the sensitivity curve corresponding to the shape of the projected dimension of the anode. The SSPMT remains an attractive new technology in gamma-ray spectroscopy, and promises to make significant improvements in the area of uranium exploration instrumentation. 16 figures, 5 tables

  16. Pneumatic tube-transported blood samples in lithium heparinate gel separator tubes may be more susceptible to haemolysis than blood samples in serum tubes.

    Science.gov (United States)

    Böckel-Frohnhöfer, Nicole; Hübner, Ulrich; Hummel, Björn; Geisel, Jürgen

    2014-10-01

    Pneumatic tube systems are widely used in hospitals. Advantages are high speed and rapid availability of the samples. However, the transportation by pneumatic tube promotes haemolysis. Haemolysis interferes with many spectrophotometric assays and is a common problem in clinical laboratories. The haemolysis index (HI) as a semi-quantitative representation of the level of haemolysis was compared in unpaired tube-transported and hand-delivered routine lithium heparinate plasma samples (n = 1368 and n = 837, respectively). Additionally, the HI distribution was measured in lithium heparinate plasma samples with a HI above the threshold value of 20 and in paired serum samples after transportation by pneumatic tube system. HI values above 20 can interfere with the selected assays: Creatine kinase (CK), creatine kinase-MB (CK-MB) and alanine aminotransferase (ALT) activities. These parameters were determined to demonstrate how haemolysis affects the results. 17.5% of the tube-transported plasma samples and 2.6% of the hand-delivered plasma samples had a HI above 20. The median HI in pneumatic tube-transported lithium heparinate plasma was 85 and 33 in the paired serum samples. The median HI difference between paired plasma and serum was 46. Blood samples in lithium heparinate tubes may be substantially more susceptible to haemolysis by pneumatic tube transportation than serum tube samples. Although our results cannot be universally applied to laboratories with different pneumatic tube systems, it is recommended that each laboratory evaluate carefully the degree of haemolysis after the transportation by the own pneumatic tube system and in terms of the sample type.

  17. New techniques for stenting severely strictured or occluded ureters

    Energy Technology Data Exchange (ETDEWEB)

    Mygind, T; Dorph, S; Nielsen, H; Nielsen, L

    1985-11-01

    Percutaneous stenting of the severely strictured ureter is facilitated by catheterization through a rigid curved tube leading through the kidney. Alternatively, bidirectional traction tensioning of a guide wire pulled through the entire urinary tract permits antegrade dilatation and stent drainage. Complete occlusion near the ureteric orifice may be bypassed by transureteral puncture of the bladder followed by stent insertion.

  18. Computerized Italian criticality guide, description and validation

    International Nuclear Information System (INIS)

    Carotenuto, M.; Landeyro, P.A.

    1988-10-01

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  19. Computerized Italian criticality guide, description and validation

    Energy Technology Data Exchange (ETDEWEB)

    Carotenuto, M; Landeyro, P A [ENEA - Dipartimento Ciclo del Combustibile, Centro Ricerche Energia, Casaccia (Italy)

    1988-10-15

    Our group is developing an 'expert system' for collecting engineering know-how on back-end nuclear plant design. An expert system is the most suitable software tool for our problem. During the analysis, the design process was divided into different branches. At each branch of the design process the Expert System relates a computerized design procedure. Any design procedure is composed of a set of design methods, together with their condition of application and reliability limits. In the framework of this expert system, the nuclear criticality safety analysis procedure was developed, in the form of a computerized criticality guide, attempting to reproduce the designer's normal 'reasoning' process. The criticality guide is composed of two parts: A computerized text, including theory, a description of the accidents occurred in the past and a description of the italian design experience; An interactive computer aided calculation module, containing a graphical facility for critical parameter curves. In the present report are presented the criticality guide (computerized Italian Criticality Guide) and its validation test. (author)

  20. SCC analysis of Alloy 600 tubes from a retired steam generator

    Science.gov (United States)

    Hwang, Seong Sik; Kim, Hong Pyo

    2013-09-01

    Steam generators (SG) equipped with Alloy 600 tubes of a Korean nuclear power plants were replaced with a new one having Alloy 690 tubes in 1998 after 20 years of operation. To set up a guide line for an examination of the other SG tubes, a metallographic examination of the defected tubes was carried out. A destructive analysis on 71 tubes was addressed, and a relation among the stress corrosion crack (SCC) defect location, defect depth, and location of the sludge pile was obtained. Tubes extracted from the retired SG were transferred to a hot laboratory. Detailed nondestructive analysis examinations were taken again at the laboratory, and the tubes were then destructively examined. The types and sizes of the cracks were characterized. The location and depth of the SCC were evaluated in terms of the location and height of the sludge. Most axial cracks were in the sludge pile, whereas the circumferential ones were around the top of the tube sheet (TTS) or below the TTS. Average defect depth of the axial cracks was deeper than that of the circumferential ones. Axial cracks at tube support plate (TSP) seem to be related with corrosion/sludge in crevice like at the TTS region. Circumferential cracks at TSP seem to be caused by tube denting at the upper part of the TSP. Tubes not having clear ECT signals for quantifying an ECT data-base. Tubes having no ECT signal. Tubes with a large ECT signal. Tubes with various types and sizes of flaws (primary water stress corrosion cracking (PWSCC), outside diameter stress corrosion cracking (ODSCC), Pit). Tubes with distinct PWSCC or ODSCC. Tubes were extracted from the RSG based on the field ECT with the criteria, and transferred to a hot laboratory at the Korea Atomic Energy Research Institute (KAERI) for destructive examination. A comprehensive ECT inspection was performed again at the hot laboratory to confirm the location of the cracks obtained from a field inspection. These exact locations of the defects were marked on the