WorldWideScience

Sample records for current test system

  1. Eddy current testing system for bottom mounted instrumentation welds

    OpenAIRE

    Kobayashi Noriyasu; Ueno Souichi; Suganuma Naotaka; Oodake Tatsuya; Maehara Takeshi; Kasuya Takashi; Ichikawa Hiroya

    2015-01-01

    The capability of eddy current testing (ECT) for the bottom mounted instrumentation (BMI) weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on th...

  2. New eddy current testing system in steam generator tubes

    International Nuclear Information System (INIS)

    Nagata, Yasuyuki; Shimone, Junri; Maeda, Kotaro; Harada, Yutaka; Murakami, Ryuji

    2003-01-01

    Eddy Current Testing (ECT) technique is applied to PWR Steam Generator (SG) tubes during refueling outage inspection. Bobbin type probe is generally used for the inspection, but it cannot provide sufficient detectability for very tight cracks. NEL, R/D Tech (Canada) and AECL (Canada) jointly developed new ECT probe. The probe is transmit and receive type array probe. It has axial defect detection mode and circumferential defect detection mode. Its inspection speed is as fast as conventional bobbin probe, and detectability performance is same or better than performance of rotating pancake coil (RPC) probe, which is used for detailed inspection. As a tester of the new probe, we have developed new ECT tester TC7700. It is able to transmit composite wave from the 4 independent oscillators (simultaneous excitation system) compared with the conventional inspection system. As regarding for field inspection system, we have integrated Zetec (USA) probe positioner, probe pusher and R/D Tech TC7700. We are also developing new analysis software. The software has automated data screening function, which can deal with large amount of data compared with conventional bobbin probe. We plan to perform a large-scale field trial using the probe and new system in near future. (author)

  3. Eddy current testing system for bottom mounted instrumentation welds - 15206

    International Nuclear Information System (INIS)

    Kobayashi, N.; Ueno, S.; Suganuma, N.; Oodake, T.; Maehara, T.; Kasuya, T.; Ichikawa, H.

    2015-01-01

    We have demonstrated the scanning of eddy current testing (ECT) probe on the welds area including the nozzle, the J-welds and the buildup welds of the Bottom Mounted Instrumentation (BMI) mock-up using the developed ECT system and procedure. It is difficult to scan the probe on the BMI welds area because the area has a complex curved surface shape and narrow spaces. We made the space coordinates and the normal vectors on the scanning points as the scanning trajectory of probe on the welds area based on the measured results of welds surface shape on the mock-up. The multi-axis robot was used to scan the probe on the welds surface. Each motion axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. The BMI mock-up test was performed using the cross coil probe in the differential mode. The artificial stress corrosion cracking and the electrical discharge machining slits given on the mock-up surface were detected. The results show that the ECT can detect a defect of approximately 2.3 mm in length, 0.5 mm in depth and 0.2 mm in width for the BMI welds. From the output voltage of single coil, we estimated that the average and the maximum probe tilt angles on the mock-up surface under scanning were 2.6 degrees and 8.5 degrees, respectively

  4. Eddy current testing system for bottom mounted instrumentation welds

    Directory of Open Access Journals (Sweden)

    Kobayashi Noriyasu

    2015-01-01

    Full Text Available The capability of eddy current testing (ECT for the bottom mounted instrumentation (BMI weld area of reactor vessel in a pressurized water reactor was demonstrated by the developed ECT system and procedure. It is difficult to position and move the probe on the BMI weld area because the area has complexly curved surfaces. The space coordinates and the normal vectors at the scanning points were calculated as the scanning trajectory of probe based on the measured results of surface shape on the BMI mock-up. The multi-axis robot was used to move the probe on the mock-up. Each motion-axis position of the robot corresponding to each scanning point was calculated by the inverse kinematic algorithm. In the mock-up test, the probe was properly contacted with most of the weld surfaces. The artificial stress corrosion cracking of approximately 6 mm in length and the electrical-discharge machining slit of 0.5 mm in length, 1 mm in depth and 0.2 mm in width given on the weld surface were detected. From the probe output voltage, it was estimated that the average probe tilt angle on the surface under scanning was 2.6°.

  5. Current operations and experiments at the Tritium Systems Test Assembly

    International Nuclear Information System (INIS)

    Bartlit, J.R.; Anderson, J.L.

    1985-01-01

    The Tritium Systems Test Assembly (TSTA) has continued to move toward operation of a fully-integrated, full-sized, computer-controlled fusion fuel processing loop. Concurrent, nonloop experiments have answered important questions on new components and issues such as palladium diffusion membranes, ceramic electrolysis cells, regenerable tritium getters, laser Raman spectroscopy, unregenerable tritium inventory on molecular sieves, tritium contamination problems and decontamination methods, and operating data on reliability, emissions, doses, and wastes generated. 4 refs., 2 figs

  6. An automatic monitoring system of leak current for testing TGC detectors based on LabVIEW

    International Nuclear Information System (INIS)

    Feng Cunfeng; Lu Taiguo; Yan Zhen; Wang Suojie; Zhu Chengguang; Sun Yansheng; He Mao

    2005-01-01

    An automatic monitoring system of leak current for testing TGC detectors with high voltage was set up by using the graphic LabVIEW platform and NI 4351 data acquisition card. The leak current was automatically monitored and recorded with this system, the time and the value of the leak current were showed instantly. Good efficiency and precision of monitoring were obtained. (authors)

  7. Automated WWER steam generator eddy current testing and plugging control system

    International Nuclear Information System (INIS)

    Gorecan, I.; Gortan, K.; Grzalja, I.

    2004-01-01

    The structural architecture of the system contains three main components which are described as follows: Manipulator Guidance System; Eddy Current Testing System; Plugging System. The manipulator system has the task to position the end-effectors to the desired tube position. When the final position is reached, the Eddy Current testing system performs data acquisition. In case defects are found, the plugging system performs tube plug installment. Each system is composed of 3 layers. The first layer is the hardware layer consisting of motors driving the effectors along with sensors needed to obtain the positioning data, pusher motors used to push the test probes into tubes of the WWER steam generator, and plugging hardware tool. The second layer is the control box performing basic monitoring and control routines as an interconnection between first and third layer. The highest layer is the control software, running on the PC, which is used as a human-machine-interface.(author)

  8. Development and evaluation of an automated system for testing current meters

    Directory of Open Access Journals (Sweden)

    Ezequiel Saretta

    2016-02-01

    Full Text Available ABSTRACT Current meters are equipment widely used for estimating flow velocity in rivers and streams. Periodic calibrations of current meters are important to ensure the quality of measurements, but the required testing facilities are complex and only available in a few institutions. However, advances in electronics and automation may contribute to developing simple and reliable calibration systems. Thus, this study aimed to develop an automated system for testing current meters, which consisted of a trapezoidal channel, a step motor, a tow car and a management system, composed of a supervisory application and microprocessed modules to control the motor and the data acquisition. Evaluations of the displacement velocity showed that it matched the reference value up to 1.85 m s-1 for a vertical-axis current meter and 2.3 m s-1 for a horizontal-axis one. The developed system showed reliability during tests, for both current meter movement and data acquisition. The management of the system based on the developed modules and the supervisory application improved its user interface, turning all the procedure into a simple task.

  9. Design and Test of a Thermal Triggered Persistent Current System using High Temperature Superconducting Tapes

    Energy Technology Data Exchange (ETDEWEB)

    Park, Dong Keun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Kang, Hyoungku [Electro-Mechanical Research Institute, Hyundai Heavy Industries, Yongin (Korea, Republic of); Ahn, Min Cheol [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yang, Seong Eun [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Yoon, Yong Soo [Department of Electrical Engineering, Ansan College of Technology, 671 Choji-Dong, Danwon-Gu, Ansan, 425-792 (Korea, Republic of); Lee, Sang Jin [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of); Ko, Tae Kuk [Department of Electrical and Electronic Engineering, Yonsei University, Shinchon-Dong 134, Seodaemun-Gu, Seoul 120-749 (Korea, Republic of)

    2006-06-01

    A superconducting magnet which is operated in persistent current mode in SMES, NMR, MRI and MAGLEV has many advantages such as high uniformity of magnetic field and reduced thermal loss. A high temperature superconducting (HTS) persistent current switch (PCS) system was designed and tested in this research. The HTS PCS was optimally designed using two different HTS tapes, second generation coated conductor (CC) HTS tape and Bi-2223 HTS tape by the finite element method (FEM) in thermal quench characteristic view. The CC tape is more prospective applicable wire in these days for its high n value and critical current independency from external magnetic field than Bi-2223 tape. Also a prototype PCS system using Bi-2223 tape was manufactured and tested. The PCS system consists of a PCS part, a heater which induces the PCS to quench, and a superconducting magnet. The test was performed in various conditions of transport current. An initial current decay appeared when the superconducting magnet was energized in a PCS system was analyzed. This paper would be foundation of HTS PCS researches.

  10. Analyses and tests for the baking system of the RFX vacuum vessel by eddy currents

    International Nuclear Information System (INIS)

    Collarin, P.; Sonato, P.; Zaccaria, P.; Zollino, G.

    1995-01-01

    The electrical, thermal and mechanical analyses carried out for the design of a new baking system for RFX by eddy currents are presented. The results of an experimental test on RFX with low heating power are reported as well. They gave confidence in the numerical analyses so as the working conditions with the nominal heating power were computed. (orig.)

  11. Analyses and tests for the baking system of the RFX vacuum vessel by eddy currents

    Energy Technology Data Exchange (ETDEWEB)

    Collarin, P. [Gruppo di Padova per Ricerche sulla Fusione, Univ. di Padova (Italy); Sonato, P. [Gruppo di Padova per Ricerche sulla Fusione, Univ. di Padova (Italy); Zaccaria, P. [Gruppo di Padova per Ricerche sulla Fusione, Univ. di Padova (Italy); Zollino, G. [Gruppo di Padova per Ricerche sulla Fusione, Univ. di Padova (Italy)

    1995-12-31

    The electrical, thermal and mechanical analyses carried out for the design of a new baking system for RFX by eddy currents are presented. The results of an experimental test on RFX with low heating power are reported as well. They gave confidence in the numerical analyses so as the working conditions with the nominal heating power were computed. (orig.).

  12. Real time data acquisition system for the High Current Test Facility proton accelerator

    International Nuclear Information System (INIS)

    Langlais, C.E.; Erickson, P.D.; Caissie, L.P.

    1975-01-01

    A real time data acquisition system was developed to monitor and control the High Current Test Facility Proton Accelerator. It is a PDP-8/E computer system with virtual memory capability that is fully interrupt driven and operates under a real-time, multi-tasking executive. The application package includes mode selection to automatically modify programs and optimize operation under varying conditions. (U.S.)

  13. An integrated automatic system for the eddy-current testing of the steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Hee Gon; Choi, Seong Su [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1995-12-31

    This research project was focused on automation of steam generator tubes inspection for nuclear power plants. ECT (Eddy Current Testing) inspection process in nuclear power plants is classified into 3 subprocesses such as signal acquisition process, signal evaluation process, and inspection planning and data management process. Having been automated individually, these processes were effectively integrated into an automatic inspection system, which was implemented in HP workstation with expert system developed (author). 25 refs., 80 figs.

  14. An integrated automatic system for the eddy-current testing of the steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Woo, Hee Gon; Choi, Seong Su [Korea Electric Power Corp. (KEPCO), Taejon (Korea, Republic of). Research Center

    1996-12-31

    This research project was focused on automation of steam generator tubes inspection for nuclear power plants. ECT (Eddy Current Testing) inspection process in nuclear power plants is classified into 3 subprocesses such as signal acquisition process, signal evaluation process, and inspection planning and data management process. Having been automated individually, these processes were effectively integrated into an automatic inspection system, which was implemented in HP workstation with expert system developed (author). 25 refs., 80 figs.

  15. Design and initial tests of beam current monitoring systems for the APS transport lines

    International Nuclear Information System (INIS)

    Wang, Xucheng.

    1992-01-01

    The non-intercepting beam current monitoring systems suitable for a wide, range of beam parameters have been developed for the Advanced Photon Source (APS) low energy transport lines and high energy transport line. The positron or electron beam pulse in the transport lines wig have peak beam currents ranging from 8 mA to 29 A with pulse widths varying from 120 ps to 30 ns and pulse repetition rates from 2 Hz to 60 Hz. The peak beam current or total beam charge is measured with the fast or integrating current transformer, respectively, manufactured by Bergoz. In-house high speed beam signal processing electronics provide a DC level output proportional to the peak current or total charge for the digitizer input. The prototype systems were tested on the linacs which have beam pulse structures similar to that of the APS transport lines. This paper describes the design of beam signal processing electronics and grounding and shielding methods for current transformers. The results of the initial operations are presented. A short introduction on the preliminary design of current monitoring systems for the APS rings is also included

  16. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Queral, V., E-mail: vicentemanuel.queral@ciemat.es [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Urbon, J. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Garcia, A.; Cuarental, I.; Mota, F. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Micciche, G. [CR ENEA Brasimone, I-40035 Camugnano (BO) (Italy); Ibarra, A. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Rapisarda, D. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain); Instituto de Fusion Nuclear, Universidad Politecnica de Madrid, 28006 Madrid (Spain); Casal, N. [Laboratorio Nacional de Fusion, EURATOM-CIEMAT, 28040 Madrid (Spain)

    2011-10-15

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  17. Preliminary definition of the remote handling system for the current IFMIF Test Facilities

    International Nuclear Information System (INIS)

    Queral, V.; Urbon, J.; Garcia, A.; Cuarental, I.; Mota, F.; Micciche, G.; Ibarra, A.; Rapisarda, D.; Casal, N.

    2011-01-01

    A coherent design of the remote handling system with the design of the components to be manipulated is vital for reliable, safe and fast maintenance, having a decisive impact on availability, occupational exposures and operational cost of the facility. Highly activated components in the IFMIF facility are found at the Test Cell, a shielded pit where the samples are accurately located. The remote handling system for the Test Cell reference design was outlined in some past IFMIF studies. Currently a new preliminary design of the Test Cell in the IFMIF facility is being developed, introducing important modifications with respect to the reference one. This recent design separates the previous Vertical Test Assemblies in three functional components: Test Modules, shielding plugs and conduits. Therefore, it is necessary to adapt the previous design of the remote handling system to the new maintenance procedures and requirements. This paper summarises such modifications of the remote handling system, in particular the assessment of the feasibility of a modified commercial multirope crane for the handling of the weighty shielding plugs for the new Test Cell and a quasi-commercial grapple for the handling of the new Test Modules.

  18. Eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Song, Sung Jin; Lee, Hyang Beom; Kim, Young Hwan [Soongsil Univ., Seoul (Korea, Republic of); Shin, Young Kil [Kunsan Univ., Gunsan (Korea, Republic of)

    2004-02-15

    Eddy current testing has been widely used for non destructive testing of steam generator tubes. In order to retain reliability in ECT, the following subjects were carried out in this study: numerical modeling and analysis of defects by using BC and RPC probes in SG tube, preparation of absolute coil impedance plane diagram by FEM. Signal interpretation of the eddy current signals obtained from nuclear power plants.

  19. Eddy current testing

    International Nuclear Information System (INIS)

    Song, Sung Jin; Lee, Hyang Beom; Kim, Young Hwan; Shin, Young Kil

    2004-02-01

    Eddy current testing has been widely used for non destructive testing of steam generator tubes. In order to retain reliability in ECT, the following subjects were carried out in this study: numerical modeling and analysis of defects by using BC and RPC probes in SG tube, preparation of absolute coil impedance plane diagram by FEM. Signal interpretation of the eddy current signals obtained from nuclear power plants

  20. An Eddy Current Testing Platform System for Pipe Defect Inspection Based on an Optimized Eddy Current Technique Probe Design

    Science.gov (United States)

    Rifai, Damhuji; Abdalla, Ahmed N.; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A.

    2017-01-01

    The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient. PMID:28335399

  1. Eddy-current testing of nuclear fuel cladding tubes using tilted encircling coil system, 1

    International Nuclear Information System (INIS)

    Yin, Renzhong; Sekine, Kazuyoshi; Shimizu, Hisaji; Tsukui, Kazushige; Urata, Megumu.

    1989-01-01

    The eddy current testing method with external encircling-coils has been widely used as a standard technique for inspection of defects in irradiated zircaloy cladding tubes. In this inspection, the systematic procedure to reliably characterize defects is required. This paper describes the newly developed external tilted encircling-coil system, in which the coil axis is inclined by an angle α to the sample tube axis, for reliable determination of the sort, location and size of defects. As the results of experimental work concerning some kinds of artificial defects in zircaloy cladding tubes using newly designed tilted coil system, an adaptable general-procedure for characterization of defects has been proposed. Furthermore, it has been confirmed that in the case of smaller tilt angles of coil, the signal-to noise ratio for defect response in this coil system is approximately equal to that of ordinary encircling coil system. (author)

  2. Transmission line component testing for the ITER Ion Cyclotron Heating and Current Drive System

    Science.gov (United States)

    Goulding, Richard; Bell, G. L.; Deibele, C. E.; McCarthy, M. P.; Rasmussen, D. A.; Swain, D. W.; Barber, G. C.; Barbier, C. N.; Cambell, I. H.; Moon, R. L.; Pesavento, P. V.; Fredd, E.; Greenough, N.; Kung, C.

    2014-10-01

    High power RF testing is underway to evaluate transmission line components for the ITER Ion Cyclotron Heating and Current Drive System. The transmission line has a characteristic impedance Z0 = 50 Ω and a nominal outer diameter of 305 mm. It is specified to carry up to 6 MW at VSWR = 1.5 for 3600 s pulses, with transient voltages up to 40 kV. The transmission line is actively cooled, with turbulent gas flow (N2) used to transfer heat from the inner to outer conductor, which is water cooled. High voltage and high current testing of components has been performed using resonant lines generating steady state voltages of 35 kV and transient voltages up to 60 kV. A resonant ring, which has operated with circulating power of 6 MW for 1 hr pulses, is being used to test high power, low VSWR operation. Components tested to date include gas barriers, straight sections of various lengths, and 90 degree elbows. Designs tested include gas barriers fabricated from quartz and aluminum nitride, and transmission lines with quartz and alumina inner conductor supports. The latest results will be presented. This manuscript has been authored by UT-Battelle, LLC, under Contract No. DE-AC05-00OR22725 with the U.S. Department of Energy.

  3. Large fluctuations of the macroscopic current in diffusive systems: a numerical test of the additivity principle.

    Science.gov (United States)

    Hurtado, Pablo I; Garrido, Pedro L

    2010-04-01

    Most systems, when pushed out of equilibrium, respond by building up currents of locally conserved observables. Understanding how microscopic dynamics determines the averages and fluctuations of these currents is one of the main open problems in nonequilibrium statistical physics. The additivity principle is a theoretical proposal that allows to compute the current distribution in many one-dimensional nonequilibrium systems. Using simulations, we validate this conjecture in a simple and general model of energy transport, both in the presence of a temperature gradient and in canonical equilibrium. In particular, we show that the current distribution displays a Gaussian regime for small current fluctuations, as prescribed by the central limit theorem, and non-Gaussian (exponential) tails for large current deviations, obeying in all cases the Gallavotti-Cohen fluctuation theorem. In order to facilitate a given current fluctuation, the system adopts a well-defined temperature profile different from that of the steady state and in accordance with the additivity hypothesis predictions. System statistics during a large current fluctuation is independent of the sign of the current, which implies that the optimal profile (as well as higher-order profiles and spatial correlations) are invariant upon current inversion. We also demonstrate that finite-time joint fluctuations of the current and the profile are well described by the additivity functional. These results suggest the additivity hypothesis as a general and powerful tool to compute current distributions in many nonequilibrium systems.

  4. Testing Solutions of the Protection Systems Provided with Delay Maximum Current Relays

    Directory of Open Access Journals (Sweden)

    Horia BALAN

    2017-12-01

    Full Text Available Relay protection is one of the main forms of automation control of electro energy systems, having as primary aims fault detection and disconnection of the faulty element in order to avoid the extent of damages and the as fast as possible recovery to the normal operation regime for the rest of the system. Faults that occur in the electro energy system can be classified considering on one hand their causes and on the other their types, but in the vast majority of cases the causes of the faults are combined. Further, considering their nature, faults are classified in faults due to the insulation’s damage, in faults due to the destruction of the integrity of the circuits and faults determined by interruptions. With respect to their nature, faults are short circuits, earthing faults and phases interruptions. At the same time, considering their type, faults are divided in transversal and longitudinal ones. The paper presents a testing solution of the delayed maximal current relays using a T3000 ISA Test measuring equipment.

  5. Eddy current testing system with integrated fluxgate magnetometer; Wirbelstrompruefsystem mit integriertem Fluxgate-Magnetometer

    Energy Technology Data Exchange (ETDEWEB)

    Kreutzbruck, M. v.; Allweins, K.; Heiden, C. [Giessen Univ. (Germany)

    2000-07-01

    The eddy current testing system described uses Foerster probes for low-frequency magnetic field detection. The major objective is to detect deep flaws in specimens/materials with good conductivity, such as aluminum. Deep flaws could be reliably detected using low excitation frequencies of a few 100 Hz and an evaluation software and data acquisition hardware matching the high dynamics of the Foerster probe. (orig./CB) [German] Es wurde ein Wirbelstromsystem auf der Basis von Foerstersonden zur niederfrequenten Magnetfelddetektion aufgebaut. Das Hauptaugenmerk hierbei lag auf der Detektion von tiefliegenden Fehlerstrukturen in gut leitfaehigen Pruefteilen, wie Aluminiumstrukturen. In Kombination mit einer an den hohen Dynamik bereich einer Foerstersonde angepassten Auswerteelektronik und Datenaufnahme konnten mittels niedrigen Anregungsfrequenzen von wenigen 100 Hz tiefliegende Fehlerstrukturen zuverlaessig detektiert werden. (orig.)

  6. Validation Test Results for Orthogonal Probe Eddy Current Thruster Inspection System

    Science.gov (United States)

    Wincheski, Russell A.

    2007-01-01

    Recent nondestructive evaluation efforts within NASA have focused on an inspection system for the detection of intergranular cracking originating in the relief radius of Primary Reaction Control System (PCRS) Thrusters. Of particular concern is deep cracking in this area which could lead to combustion leakage in the event of through wall cracking from the relief radius into an acoustic cavity of the combustion chamber. In order to reliably detect such defects while ensuring minimal false positives during inspection, the Orthogonal Probe Eddy Current (OPEC) system has been developed and an extensive validation study performed. This report describes the validation procedure, sample set, and inspection results as well as comparing validation flaws with the response from naturally occuring damage.

  7. Development of intelligent Eddy Current Testing (ECT) system for PWR steam generator tube inspection

    International Nuclear Information System (INIS)

    Kawata, K.; Kawase, N.; Kurokawa, M.; Asada, Y.

    2005-01-01

    The intelligent ECT system was developed for the inspection of heat transfer tubes of the steam generator of the PWR plant. It consists of intelligent probe, data acquisition unit and data analysis system. The probe combines 24 channels inclined lay out drive coils and thin film pick-up coils with built-in electric circuits to provide high inspection capability equivalent to rotating coil ECT and high-speed inspection equivalent to conventional bobbin coil ECT. The advanced data analysis system that has filtering and automatic analysis functions is also developed to enable fast and precise analysis of large volume inspection data. The system was qualified by confirmation tests in FY 2003 to show thinned thickness sizing accuracy within ± 5%. (T. Tanaka)

  8. Expert system for eddy current signal analysis: non destructive testing of steam generator tubings

    International Nuclear Information System (INIS)

    Benoist, B.

    1991-01-01

    Automatic analysis, by computer, of defect signals in steam generator tubes, based on Eddy current multifrequency technique, is must often inefficient due to pilgrim noise. The first step is to use a method that allows us to eleminate the noise: the adaptative interpolation. Thanks to this method, which ensures reliable data on each channel, the analysis can be realised by taking into account the data corresponding to each basic or mixed channel. By correlating these diverse data, we can class the signals according to two types of defects: single defects (symmetrical), multiple defects (several in the same place). The second step is to use an expert system which allows a reliable diagnosis for whatever family the defect belongs to. According to this classification, analysis is continued and results in the characterization of the defect. The expert system has already been developed with the general purpose application expert system shell SUPER, which is briefly described. The knowledge base (SOCRATE) and the specific tools developed for this application are thoroughly described. The first results obtained with signals corresponding to real defects, that have been recorded in different places, are presented and discussed. The expert system is revealed efficient in all the studied cases, even with signals obtained in very noisy environments [fr

  9. Design Studies for a High Current Bunching System for CLIC Test Facility (CTF3) Drive Beam

    CERN Document Server

    Thiery, Y.; Le Duff, J.

    2000-01-01

    A bunching system is proposed for the initial stage of CTF3 which consists of one (two) 3 GHz prebunchers and one 3 GHz travelling wave (TW) buncher with variable phase velocities. The electron beam is emitted from a 140 KV DC gun. Since the macropulse beam current (3.5 A) at the exit of the TW buncher is rather high, inside the TW buncher one has to take the beam loading effect into consideration. By using PARMELA, it is shown numerically that the bunching system can provide the bunches whose properties satisfy the design requirement of CTF3. The 0.8 m long TW buncher working at 2pi/3 mode has two phase velocities, 0.75 and 1. The dimensions of the caities in the two phase velocity regions are proposed considering the beam loading effect. The transient beam loading effect and the multibunch transverse instabilities are studied numerically, and it is concluded that higher order mode couplers should be installed in the TW buncher with the loaded quality factor of the dipole mode lower than 80.

  10. Development of an on-site calibration method for a current transformer testing system and its application

    International Nuclear Information System (INIS)

    Jung, Jae Kap; Lee, Sang Hwa; Kwon, Sung Won; Park, Young Tae

    2008-01-01

    The ratio error and phase displacement of a current transformer (CT) are measured by using a CT testing system, which consists of a current source, a standard CT, a CT under test, a CT comparator and a CT burden. Methods for on-site calibration of the components in CT testing systems in industry have been developed recently, which do not require any component to be detached from the systems. The method utilizes several travelling transfer standards: standard CTs, non-reactive standard resistors, a calculable wide-ratio error CT and non-reactive shunt resistors. The travelling standard CT is used for absolute evaluation of a current source and a standard CT of industry. The non-reactive standard resistors and the calculable wide-ratio error CT are used to evaluate the linearity of the errors in the CT comparator. The shunt resistors are used to evaluate the CT burden of industry. The on-site calibration method using these travelling transfer standards has been successfully applied to calibration of CT testing systems in industries

  11. Recent developments at CNR-INSEAN on testing and modelling marine renewable energy systems for waves and currents

    International Nuclear Information System (INIS)

    Salvatore, Francesco; Di Felice, Fabio; Fabbri Luigi

    2015-01-01

    Hydrodynamic testing centers are nowadays challenged by a continuously increasing demand for studies aimed at the development, verification and assessment of marine renewable energy capturing systems. This paper describes the experience matured over the last years at CNR-INSEAN, the marine technology research Institute of the Italian National Research Council. Originally designed for hydrodynamics testing of marine vehicles, the Institute’s experimental facilities like wave and calm water tanks, circulating water channel, now host testing programs on wave energy converters, marine current turbines and hybrid systems, combining devices to extract energy from different marine sources like waves and winds. Selected case studies are described and main findings are discussed in the paper.

  12. Method for critical current testing

    International Nuclear Information System (INIS)

    Siddall, M.B.; Smathers, D.B.

    1989-01-01

    Superconducting critical current testing software was developed with four important features not feasible with analog test equipment. First, quasi-steady-state sample current conditions are achieved by incrementing sample current, followed by holding some milliseconds until the transient voltage decays before voltage sampling. Then the self-field correction from a helically wound sample is computed and subtracted from each sampled field reading. A copper wire inductively wound shunt which is used for quench protection has a constant measured resistance from which the shunt leakage current is computed and subtracted from the sample current by measuring the shunt voltage after each sample current reading. Finally, the critical current is recomputed from a least squares curve fit to the power law: E=A*In when the correlation coefficient for the fit is high enough to ensure a better result than the raw datum. Comparison with NBS Standard Reference Material (NbTi) and current round robin Nb/sub 3/Sn testing is examined

  13. Testing components of Rothbard’s theory with the current information system

    Directory of Open Access Journals (Sweden)

    Aurelian Virgil BĂLUŢĂ

    2016-03-01

    Full Text Available The concept of aggression against property rights of individuals generates a series of developments that allow solutions and options to problems and dilemmas of today's economy: the dynamics of the tax system, focusing attention on shaping the budget with macro-economic calculations, the protection of competition, and customs policy in the modern era. The confidence in theory in general, especially in economic theory, is based on the logical and methodological validation of scientific reasoning and moral aspects. Transforming the theory into a means of changing the society can only be made when a theory is experimentally validated. The economic theory needs confirmation from specialized disciplines such as statistics and accounting. It is possible and necessary for the advantages of radical liberal thinking to be reflected in every company’s bookkeeping and in public statistics. As an example, the paper presents the way some components of Rothbard's theory are reflect in the accounting and statistics information system.

  14. Eddy current testing, volume 1

    International Nuclear Information System (INIS)

    Cecco, V.S.; Van Drunen, G.; Sharp, F.L.

    1981-11-01

    This training and reference manual was assembled to provide those involved in eddy current testing with both the fundamental principles of the technique as well as the knowledge to deal with often complicated test results. A non-rigorous approach is used to simplify complex physical phenomena. Emphasis is placed on proper choice of test frequency and interpretation. Defect detection and diagnosis receive particular attention. Design and construction of probes are covered extensively since probes play a key role in eddy current testing. The advantages and limitations of various probe types are discussed. Electromagnetic theory, instrumentation, test methods and signal analysis are covered. Simplified derivations of probe response to test parameters are presented to develop a basic understanding of eddy current behaviour. Eddy current signals are presented on impedance plane diagrams throughout the manual since this is the most common display on modern, general purpose instruments. The use of 'phase leg' in signal analysis is covered in detail. To supplement theory, practical examples are presented to develop proficiency in performing inspections, and to illustrate how basic principles are applied to diagnose real signals

  15. Remote field eddy current testing

    International Nuclear Information System (INIS)

    Cheong, Y. M.; Jung, H. K.; Huh, H.; Lee, Y. S.; Shim, C. M.

    2001-03-01

    The state-of-art technology of the remote field eddy current, which is actively developed as an electromagnetic non-destructive testing tool for ferromagnetic tubes, is described. The historical background and recent R and D activities of remote-field eddy current technology are explained including the theoretical development of remote field eddy current, such as analytical and numerical approach, and the results of finite element analysis. The influencing factors for actual applications, such as the effect of frequency, magnetic permeability, receiving sensitivity, and difficulties of detection and classification of defects are also described. Finally, two examples of actual application, 1) the gap measurement between pressure tubes and calandria tube in CANDU reactor and, 2) the detection of defects in the ferromagnetic heat exchanger tubes, are described. The future research efforts are also included

  16. Improvement of a high current DC power supply system for testing the large scaled superconducting cables and magnets

    International Nuclear Information System (INIS)

    Yamada, Shuichi; Chikaraishi, Hirotaka; Tanahashi, Shugo

    1993-11-01

    A dc 75 kA power supply system was constructed to test the superconducting (SC) R and D cables and magnets for the Large Helical Device. It consists of three 25 kA unit banks. A unit bank has two double-star-rectifier connections with the inter-phase reactors. A digital feedback control method is applied to the automatic current regulation (ACR) in each unit bank. For shortening the dead time of the feedback process, a new algorithm of a digital phase controller for the ACR is investigated. A Bode diagram of the feedback process is directly measured. It is confirmed that the dead time of the feedback process is reduced to one sixth, and that the feedback gain of PID compensation is improved by a factor of two from the original method. (author)

  17. CURRENT TRANSFER SYSTEMS

    Science.gov (United States)

    Watt, D.A.

    1956-07-01

    A current transfer system is described for transferring current between a rotating member and a co-axial stationary member. The particular area of application for the invention is in connection with homopolar generators where a low voltage and high current are generated. The current tramsfer system of the invention comprises a rotor member and a co-axial stator member wherein one of the members is shaped to provide a circumferential surface concave in section and the other member is shaped to have a peripheral portion in close proximity to the surface, whereby a liquid metal can be stably supported between the two members when they are moving relative to one another to establish an electrical conducting path between the members.

  18. Stacouf: A new system for automatic processing of eddy current signal from steam generator testing of PWR power plants

    International Nuclear Information System (INIS)

    Ducreux, J.; Eyrolles, P.; Meylogan, T.

    1990-01-01

    A new system called STACOUF will be soon industrialized. The aim is to improve on-site signal processing for eddy testing of steam generators. Testing time, quality and productivity will be improved [fr

  19. Eddy current testing of heat exchangers tubes

    International Nuclear Information System (INIS)

    Gouez, J.F.; Rieusset, A.; Groix, F.

    An automatic system for Eddy Current testing of heat exchangers tubes of warships was developed. The advantages are an exposure of the controller limited at the time required to put in place the system and a reduced time of control [fr

  20. Current Status of Aerosol Generation and Measurement Facilities for the Verification Test of Containment Filtered Venting System in KAERI

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sung Il; An, Sang Mo; Ha, Kwang Soon; Kim, Hwan Yeol [KAERI, Daejeon (Korea, Republic of)

    2016-05-15

    In this study, the design of aerosol generation and measurement systems are explained and present circumstances are also described. In addition, the aerosol test plan is shown. Containment Filtered Venting System (FCVS) is one of the safety features to reduce the amount of released fission product into the environment by depressurizing the containment. Since Chernobyl accident, the regulatory agency in several countries in Europe such as France, Germany, Sweden, etc. have been demanded the installation of the CFVS. Moreover, the feasibility study on the CFVS was also performed in U.S. After the Fukushima accident, there is a need to improve a containment venting or installation of depressurizing facility in Korea. As a part of a Ministry of Trade, Industry and Energy (MOTIE) project, KAERI has been conducted the integrated performance verification test of CFVS. As a part of the test, aerosol generation system and measurement systems were designed to simulate the fission products behavior. To perform the integrated verification test of CFVS, aerosol generation and measurement system was designed and manufactured. The component operating condition is determined to consider the severe accident condition. The test will be performed in normal conditions at first, and will be conducted under severe condition, high pressure and high temperature. Undesirable difficulties which disturb the elaborate test are expected, such as thermophoresis on the pipe, vapor condensation on aerosol, etc.

  1. EDDY - a FORTRAN program to extract significant features from eddy-current test data - the basis of the CANSCAN system

    International Nuclear Information System (INIS)

    Jarvis, R.G.; Cranston, R.J.

    1982-09-01

    The FORTRAN program EDDY is designed to analyse data: from eddy-current scans of steam generator tubes. It is written in modular form, for future development, and it uses signal-recognition techniques that the authors developed in the profilometry of irradiated fuel elements. During a scan, significant signals are detected and extracted for immediate attention or more detailed analysis later. A version of the program was used in the CANSCAN system 'for automated eddy-current in-service inspection of nuclear steam generator tubing'

  2. Development of Multichannel Eddy Current Testing Instrument

    International Nuclear Information System (INIS)

    Lee, Hee Jong; Cho, Chan Hee; Nam, Min Woo; Yoon, Byung Sik; Yoo, Hyun Joo

    2010-01-01

    Four main techniques of electromagnetic testing are used for commercial applications: eddy current testing, alternating current field testing, magnetic flux leakage testing and remote field testing. Eddy current testing is a nondestructive evaluation method, which makes eddy current flow on a specimen by applying driving pulse to eddy current probe coil, by using eddy current testing device, and makes the change of eddy current which is dependently caused by flaws, material characteristics, testing condition, receiving through eddy current, and analyzes material properties, flaws, status on the specimen. Application of EC instrumentation varies widely in industry from the identification of metal heat treatment to the inspection of steam generator tubing in nuclear power plants. In this study, we have designed multichannel EC instrument which can be applicable to the NDE of the tube in heat exchanger for electric power facility, chemistry, and military industry, and finally confirmed the proper function of EC instrumentation

  3. Current limiter circuit system

    Science.gov (United States)

    Witcher, Joseph Brandon; Bredemann, Michael V.

    2017-09-05

    An apparatus comprising a steady state sensing circuit, a switching circuit, and a detection circuit. The steady state sensing circuit is connected to a first, a second and a third node. The first node is connected to a first device, the second node is connected to a second device, and the steady state sensing circuit causes a scaled current to flow at the third node. The scaled current is proportional to a voltage difference between the first and second node. The switching circuit limits an amount of current that flows between the first and second device. The detection circuit is connected to the third node and the switching circuit. The detection circuit monitors the scaled current at the third node and controls the switching circuit to limit the amount of the current that flows between the first and second device when the scaled current is greater than a desired level.

  4. Eddy current testing using digital technology

    International Nuclear Information System (INIS)

    Houseman, H.E.; Lamb, L.T.; Kitson, B.

    1985-01-01

    Eddy current inspection techniques have been used extensively in industry as an accepted method of non-destructive testing. The application of this technology has proven invaluable for both the control of product quality during the manufacturing process as well as the verification of material integrity throughout the life of a given component. One of the major areas in the power industry where eddy current techniques have been used is for the inspection of installed tubing in various heat exchangers including the steam generators of pressurized water reactor (PWR) nuclear steam supply systems. As increased emphasis is placed upon the operability and safety of these components, test instrumentation has been advanced to improve the efficiency and reliability of inservice inspections. At the same time, plant owners along with manufacturers and inspection service vendors are developing analytical tools for assessing the inspection results. One of the techniques that offers significant potential has been made possible by recent advances in digital technology. The application of digital techniques to the eddy current method offers not only a means to improve the test instrumentation but also an environment whereby other facets of the inservice inspection effort can be enchanced

  5. Eddy current testing of composite pressure vessels

    Science.gov (United States)

    Casperson, R.; Pohl, R.; Munzke, D.; Becker, B.; Pelkner, M.

    2018-04-01

    The use of composite pressure vessels instead of conventional vessels made of steel or aluminum grew strongly over the last decade. The reason for this trend is the tremendous weight saving in the case of composite vessels. However, the long-time behavior is not fully understood for filling and discharging cycles and creep strength and their influence on the CFRP coating (carbon fiber reinforced plastics) and the internal liner (steel, aluminum, or plastics). The CFRP ensures the pressure resistance while the inner liner is used as a container for liquid or gas. To overcome the missing knowledge of aging, BAM started an internal project to investigate degradation of these material systems. Therefore, applicable testing methods like eddy current testing are needed. Normally, high-frequency eddy current testing (HF-ET, f > 10 MHz) is deployed for CFRP due to its low conductivity of the fiber, which is in the order of 0.01 MS/s, and the capacitive coupling between the fibers. Nevertheless, in some cases conventional ET can be applied. We show a concise summary of studies on the application of conventional ET of composite pressure vessels.

  6. Measurement technology of RF interference current in high current system

    Science.gov (United States)

    Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei

    2018-06-01

    Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.

  7. Eddy current testing with high penetration

    International Nuclear Information System (INIS)

    Becker, R.; Kroening, M.

    1999-01-01

    The low-frequency eddy current testing method is used when penetration into very deep layers is required. The achievable penetration depth is determined among other parameters by the lowest testing frequency that can be realised together with the eddy current sensor. When using inductive sensors, the measuring effect declines proportional to the lowering frequency (induction effect). Further reduction of testing frequency requires other types of sensors, as e.g. the GMR (Giant Magnetic Resistance), which achieves a constant measuring sensitivity down to the steady field. The multi-frequency eddy current testing method MFEC 3 of IZFP described here can be operated using three different scanning frequencies at a time. Two variants of eddy current probes are used in this case. Both have an inductive winding at their emitters, of the type of a measuring probe. The receiver end is either also an inductive winding, or a magnetic field-responsive resistance (GMR). (orig./CB) [de

  8. Eddy current testing device using unbalance bridge

    International Nuclear Information System (INIS)

    Hoshikawa, H.; Koido, J.; Ishibashi, Y.

    1976-01-01

    An easily readjustable unbalance bridge has been invented and in utilizing the same, an eddy current testing equipment excellent in suppression of the lift-off effect and high in the detection sensitivity has been developed

  9. Recognizing limitations in eddy current testing

    International Nuclear Information System (INIS)

    Van Drunen, G.; Cecco, V.S.

    1981-11-01

    This paper addresses known limitations and constraints in eddy current nondestructive testing. Incomplete appreciation for eddy current limitations is believed to have contributed to both under-utilization and misapplication of the technique. Neither situation need arise if known limitations are recognized. Some, such as the skin depth effect, are inherent to electromagnetic test methods and define the role of eddy current testing. Others can be overcome with available technology such as surface probes to find circumferential cracks in tubes and magnetic saturation of ferromagnetic alloys to eliminate permeability effects. The variables responsible for limitations in eddy current testing are discussed and where alternative approaches exist, these are presented. Areas with potential for further research and development are also identified

  10. Small test SDHW systems

    DEFF Research Database (Denmark)

    Vejen, Niels Kristian

    1999-01-01

    Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different.......Three small test SDHW systems was tested in a laboratory test facility.The three SDHW systems where all based on the low flow principe and a mantle tank but the design of the systems where different....

  11. Electronic voltage and current transformers testing device.

    Science.gov (United States)

    Pan, Feng; Chen, Ruimin; Xiao, Yong; Sun, Weiming

    2012-01-01

    A method for testing electronic instrument transformers is described, including electronic voltage and current transformers (EVTs, ECTs) with both analog and digital outputs. A testing device prototype is developed. It is based on digital signal processing of the signals that are measured at the secondary outputs of the tested transformer and the reference transformer when the same excitation signal is fed to their primaries. The test that estimates the performance of the prototype has been carried out at the National Centre for High Voltage Measurement and the prototype is approved for testing transformers with precision class up to 0.2 at the industrial frequency (50 Hz or 60 Hz). The device is suitable for on-site testing due to its high accuracy, simple structure and low-cost hardware.

  12. Development of a system for monitoring and diagnosis of steam generator tubes using artificial intelligence techniques on Eddy Current Test signals

    International Nuclear Information System (INIS)

    Mesquita, Roberto Navarro de; Ting, Daniel Kao Sun; Lopez, Luis A. Negro M.; Upadhyaya, Belle R.

    2002-01-01

    New classification and feature extraction methods for steam generator tube defects are being developed by IPEN/CNEN-SP in cooperation with UTK to improve a monitoring and diagnosis system for classification and characterization of steam generator tube defects using Eddy Current Testing (ECT) signals. The first methodology being developed uses a set of feature extraction methods applied to different tube defect type ECT signals and each obtained feature vector is projected into a bi-dimensional map obtained by a Self-Organizing Map neural network. This methodology allows an optimal feature extraction method selection for the defect type classification. Other approach is being developed using tubes with different manufactured defect types which are tested using MIZ-17ET equipment with 4 sets of probes (two different diameter). A fuzzy inference system will be used to build a knowledge base for these defects. These methodology and algorithms will be integrated into an automated diagnosis system being developed with UTK, which is designed to read both on-line acquired data, as well as stored data files. These commercial software tools are the ones usually utilized in nuclear power plants. (author)

  13. Development of a system for monitoring and diagnosis of steam generator tubes using artificial intelligence techniques on Eddy Current Test signals

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Roberto Navarro de [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Centro de Monitoracao e Diagnostico]|[Sao Paulo Univ., SP (Brazil); Ting, Daniel Kao Sun [Instituto de Pesquisas Energeticas e Nucleares (IPEN), Sao Paulo, SP (Brazil). Centro de Monitoracao e Diagnostico; Cabral, Eduardo Lobo C. [Sao Paulo Univ., SP (Brazil); Lopez, Luis A. Negro M. [Faculdade de Engenharia Industrial, Sao Bernardo do Campo, SP (Brazil); Upadhyaya, Belle R. [Tennessee Univ., Knoxville, TN (United States)

    2002-07-01

    New classification and feature extraction methods for steam generator tube defects are being developed by IPEN/CNEN-SP in cooperation with UTK to improve a monitoring and diagnosis system for classification and characterization of steam generator tube defects using Eddy Current Testing (ECT) signals. The first methodology being developed uses a set of feature extraction methods applied to different tube defect type ECT signals and each obtained feature vector is projected into a bi-dimensional map obtained by a Self-Organizing Map neural network. This methodology allows an optimal feature extraction method selection for the defect type classification. Other approach is being developed using tubes with different manufactured defect types which are tested using MIZ-17ET equipment with 4 sets of probes (two different diameter). A fuzzy inference system will be used to build a knowledge base for these defects. These methodology and algorithms will be integrated into an automated diagnosis system being developed with UTK, which is designed to read both on-line acquired data, as well as stored data files. These commercial software tools are the ones usually utilized in nuclear power plants. (author)

  14. Thin tube testing by eddy currents

    International Nuclear Information System (INIS)

    David, Bernard; Pigeon, Michel

    1981-01-01

    It is often necessary to define test conditions in eddy current testing, in consequence rules and laws allowing a rapid choice of these conditions are welcome. The similarity law, given by Forster, using the reduced frequency f/fg, allows extrapolation of results from an object to one another, if these two objects are similar (i.e. all their dimensions are proportional). In a particular case, often met, a law going further is given to describe, in a sole way, eddy current behaviour using the reduced frequency in all thin tubes (internal to external diameter ratio between 0.85 to 1). For instance working at f/fe=2 defines the same verification leading to identical results, whatever the nature, the diameter or the thickness may be, if the tubes are thin. A diagram is given and a slide-rule, based on this principle, has been realized [fr

  15. Development and Testing of Infrared Water Current Meter | Ezenne ...

    African Journals Online (AJOL)

    Continuous monitoring of the river flow is essential for assessing water availability. River flow velocity is crucial to simulate discharge hydrographs of water in the hydrological system.This study developed a digital water current meter with infrared. The infrared current meter was tested using Ebonyi River at Obollo-Etiti and ...

  16. Non-Destructive Techniques Based on Eddy Current Testing

    Science.gov (United States)

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future. PMID:22163754

  17. Current status of accreditation for drug testing in hair.

    Science.gov (United States)

    Cooper, Gail; Moeller, Manfred; Kronstrand, Robert

    2008-03-21

    At the annual meeting of the Society of Hair Testing in Vadstena, Sweden in 2006, a committee was appointed to address the issue of guidelines for hair testing and to assess the current status of accreditation amongst laboratories offering drug testing in hair. A short questionnaire was circulated amongst the membership and interested parties. Fifty-two responses were received from hair testing laboratories providing details on the amount and type of hair tests they offered and the status of accreditation within their facilities. Although the vast majority of laboratories follow current guidelines (83%), only nine laboratories were accredited to ISO/IEC 17025 for hair testing. A significant number of laboratories reporting that they were in the process of developing quality systems with a view to accrediting their methods within 2-3 years. This study provides an insight into the status of accreditation in hair testing laboratories and supports the need for guidelines to encourage best practice.

  18. Surface inspection technique with an eddy current testing array probe

    International Nuclear Information System (INIS)

    Nishimizu, Akira; Endo, Hisashi; Tooma, Masahiro; Otani, Kenichi; Ouchi, Hirofumi; Yoshida, Isao; Nonaka, Yoshio

    2010-01-01

    An eddy current testing (ECT) system has been developed for inspecting weld surfaces of components in the reactor pressure vessel of nuclear plants. The system can be applied to curved surfaces with an ECT array probe, it can discriminate flaws from other signal factors by using a combination of arrayed coils signal-phase. The system is applied to a mock-up of core internal components and the signal discrimination using the signal-phase clearly separated flaw and noise signals. (author)

  19. Seismic proving test of ultimate piping strength (current status of preliminary tests)

    International Nuclear Information System (INIS)

    Suzuki, K.; Namita, Y.; Abe, H.; Ichihashi, I.; Suzuki, K.; Ishiwata, M.; Fujiwaka, T.; Yokota, H.

    2001-01-01

    In 1998 Fiscal Year, the 6 year program of piping tests was initiated with the following objectives: i) to clarify the elasto-plastic response and ultimate strength of nuclear piping, ii) to ascertain the seismic safety margin of the current seismic design code for piping, and iii) to assess new allowable stress rules. In order to resolve extensive technical issues before proceeding on to the seismic proving test of a large-scale piping system, a series of preliminary tests of materials, piping components and simplified piping systems is intended. In this paper, the current status of the material tests and the piping component tests is reported. (author)

  20. Testing and evaluation of high temperature superconductor current leads

    International Nuclear Information System (INIS)

    Yadav, Anand; Puntambekar, Avinash; Manekar, M.A.

    2009-01-01

    National Institute for Inter-disciplinary Science and Technology (NIIST), Council of Scientific and Industrial Research, Trivandrum (formerly Regional Research Laboratory) has accomplished a DAE-BRNS project with Raja Ramanna Centre for Advanced Technology (RRCAT) as principal collaborator for the development of high temperature superconductor (HTS) current leads. These HTS current leads have self-field critical currents (Ic) ranging from 50 A to 1000 A at liquid nitrogen (LN 2 ) temperature. These HTS are made out of silver sheathed Bismuth Strontium Calcium Copper Oxide (BSCCO-2223), for direct application in superconducting (SC) systems involving transportation of high electric currents from power sources at room temperature to superconducting devices at cryogenic temperatures. RRCAT has participated in this project by testing and evaluation of these HTS current leads and carried out actual load trials. In this paper, we will describe the HTS testing setup, tests performed with their testing procedure and the test results. The testing of these HTS has been done with joint effort of Materials Advanced Accelerator Science and Cryogenics Div. and Superconducting Technology Lab (SCT Lab), Advanced Accelerator Module Development Div., using the test facility available at the SCT Lab. (author)

  1. System Performance and Testing

    NARCIS (Netherlands)

    Frei, U.; Oversloot, H.

    2004-01-01

    This chapter compares and contrasts the system performance of two widely used solar thermal systems using testing and simulation programs. Solar thermal systems are used in many countries for heating domestically used water. In addition to the simple thermosiphon systems, better designed pumped

  2. ELECTROFORCE 3330 TEST SYSTEM

    Data.gov (United States)

    Federal Laboratory Consortium — The Bose Electroforce 3330 is a test system with an axial electromagnetic linear motor, a torsional motor, and an environmental chamber for high and low temperature...

  3. Automatic Test Systems Aquisition

    National Research Council Canada - National Science Library

    1994-01-01

    We are providing this final memorandum report for your information and use. This report discusses the efforts to achieve commonality in standards among the Military Departments as part of the DoD policy for automatic test systems (ATS...

  4. Current Research/Development in Language Testing.

    Science.gov (United States)

    Oller, John W., Jr.

    A discussion of language testing looks at the relationship between the processes of language learning and language testing, particularly from the point of view of pragmatics theory. It outlines some of the theory of Charles Sanders Pierce and its role in the evolution of linguistic theory, as well as the work of other theorists concerning the…

  5. [Current status of gene test market].

    Science.gov (United States)

    Ohtani, Shinichi

    2002-12-01

    The technological innovation of the gene analysis makes the adaptation range of the gene test in clinical diagnosis expand. Then, gene test has popularized increasingly around the infection disease for clinical inspection. Also in the field of clinical inspection, the increase of the importance of clinical application and the inspection item new year by year have appeared with the functional analysis of a gene. Moreover, the new test method and automation analysis equipment tend to be developed by progress of gene-analysis technology, and it is going to be introduced. The spread of gene test and development of a gene test market have an important possibility of activating the present clinical inspection field.

  6. Defense Waste Processing Facility Canister Closure Weld Current Validation Testing

    Energy Technology Data Exchange (ETDEWEB)

    Korinko, P. S. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Maxwell, D. N. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2018-01-29

    Two closure welds on filled Defense Waste Processing Facility (DWPF) canisters failed to be within the acceptance criteria in the DWPF operating procedure SW4-15.80-2.3 (1). In one case, the weld heat setting was inadvertently provided to the canister at the value used for test welds (i.e., 72%) and this oversight produced a weld at a current of nominally 210 kA compared to the operating procedure range (i.e., 82%) of 240 kA to 263 kA. The second weld appeared to experience an instrumentation and data acquisition upset. The current for this weld was reported as 191 kA. Review of the data from the Data Acquisition System (DAS) indicated that three of the four current legs were reading the expected values, approximately 62 kA each, and the fourth leg read zero current. Since there is no feasible way by further examination of the process data to ascertain if this weld was actually welded at either the target current or the lower current, a test plan was executed to provide assurance that these Nonconforming Welds (NCWs) meet the requirements for strength and leak tightness. Acceptance of the welds is based on evaluation of Test Nozzle Welds (TNW) made specifically for comparison. The TNW were nondestructively and destructively evaluated for plug height, heat tint, ultrasonic testing (UT) for bond length and ultrasonic volumetric examination for weld defects, burst pressure, fractography, and metallography. The testing was conducted in agreement with a Task Technical and Quality Assurance Plan (TTQAP) (2) and applicable procedures.

  7. High field, low current operation of engineering test reactors

    International Nuclear Information System (INIS)

    Schwartz, J.; Cohn, D.R.; Bromberg, L.; Williams, J.E.C.

    1987-06-01

    Steady state engineering test reactors with high field, low current operation are investigated and compared to high current, lower field concepts. Illustrative high field ETR parameters are R = 3 m, α ∼ 0.5 m, B ∼ 10 T, β = 2.2% and I = 4 MA. For similar wall loading the fusion power of an illustrative high field, low current concept could be about 50% that of a lower field device like TIBER II. This reduction could lead to a 50% decrease in tritium consumption, resulting in a substantial decrease in operating cost. Furthermore, high field operation could lead to substantially reduced current drive requirements and cost. A reduction in current drive source power on the order of 40 to 50 MW may be attainable relative to a lower field, high current design like TIBER II implying a possible cost savings on the order of $200 M. If current drive is less efficient than assumed, the savings could be even greater. Through larger β/sub p/ and aspect ratio, greater prospects for bootstrap current operation also exist. Further savings would be obtained from the reduced size of the first wall/blanket/shield system. The effects of high fields on magnet costs are very dependent on technological assumptions. Further improvements in the future may lie with advances in superconducting and structural materials

  8. Multi-frequency eddy current testing method

    International Nuclear Information System (INIS)

    Levy, R.; Gallet, G.

    1980-01-01

    Monitoring by multi-frequency eddy currents has been used since 1975 in French nuclear stations; this method applies perfectly to examinations in non-irradiated surroundings. The restrictions connected with operations in controlled zones (radioactivity) have led to the development of a delayed analysis device which in no way changes the principle of the method, but allows greater flexibility of use by reducing the volume of equipment needed and by limiting the intervention of personnel to a strict minimum [fr

  9. Vehicle brake testing system

    Science.gov (United States)

    Stevens, Samuel S [Harriman, TN; Hodgson, Jeffrey W [Lenoir City, TN

    2002-11-19

    This invention relates to a force measuring system capable of measuring forces associated with vehicle braking and of evaluating braking performance. The disclosure concerns an invention which comprises a first row of linearly aligned plates, a force bearing surface extending beneath and beside the plates, vertically oriented links and horizontally oriented links connecting each plate to a force bearing surface, a force measuring device in each link, a transducer coupled to each force measuring device, and a computing device coupled to receive an output signal from the transducer indicative of measured force in each force measuring device. The present invention may be used for testing vehicle brake systems.

  10. Simulator testing system (STS)

    International Nuclear Information System (INIS)

    Miller, V.N.

    1990-01-01

    In recent years there has been a greater demand placed on the capabilities and time usage of real-time nuclear plant simulators due to NRC, INPO and utilities requirements. The requirements applied to certification, new simulators, upgrades, modifications, and maintenance of the simulators vary; however, they all require the capabilities of the simulator to be tested whether it is for NRC 10CFR55.45b requirements, ATP testing of new simulators, ATP testing of upgrades with or without panels, adding software/hardware due to plant modifications, or analyzing software/hardware problems on the simulator. This paper describes the Simulator Testing System (STS) which addresses each one of these requirements placed on simulators. Special attention will be given to ATP testing of upgrades without the use of control room panels. The capabilities and applications of the four parts of STS which are the Display Control Software (DCS), Procedure Control Software (PCS), Display Generator Software (DGS) and the Procedure Generator Software (PGS) will be reviewed

  11. Design of BEPCII bunch current monitor system

    International Nuclear Information System (INIS)

    Zhang Lei; Ma Huizhou; Yue Junhui; Lei Ge; Cao Jianshe; Ma Li

    2008-01-01

    BEPC II is an electron-positron collider designed to run under multi-bunches and high beam current condition. The accelerator consists of an electron ring, a positron ring and a linear injector. In order to achieve the target luminosity and implement the equal bunch charge injection, the Bunch Current Monitor (BCM) system is built on BEPC II. The BCM system consists of three parts: the front-end circuit, the bunch current acquisition system and the bucket selection system. The control software of BCM is based on VxWorks and EPICS. With the help of BCM system, the bunch current in each bucket can be monitored in the Central Control Room. The BEPC II timing system can also use the bunch current database to decide which bucket needs to refill to implement 'top-off' injection. (authors)

  12. Nightly Test system migration

    CERN Document Server

    Win-Lime, Kevin

    2013-01-01

    The summer student program allows students to participate to the Cern adventure. They can follow several interesting lectures about particle science and participate to the experiment work. As a summer student, I had worked for LHCb experiment. LHCb uses a lot of software to analyze its data. All this software is organized in packages and projects. They are built and tested during the night using an automated system and the results are displayed on a web interface. Actually, LHCb is changing this system. It is looking for a replacement candidate. So I was charged to unify some internal interfaces to permit a swift migration. In this document, I will describe shortly the system used by LHCb, then I will explain what I have done in detail.

  13. Current and Future Flight Operating Systems

    Science.gov (United States)

    Cudmore, Alan

    2007-01-01

    This viewgraph presentation reviews the current real time operating system (RTOS) type in use with current flight systems. A new RTOS model is described, i.e. the process model. Included is a review of the challenges of migrating from the classic RTOS to the Process Model type.

  14. Tritium Systems Test Facility

    International Nuclear Information System (INIS)

    Cafasso, F.A.; Maroni, V.A.; Smith, W.H.; Wilkes, W.R.; Wittenberg, L.J.

    1978-01-01

    This TSTF proposal has two principal objectives. The first objective is to provide by mid-FY 1981 a demonstration of the fuel cycle and tritium containment systems which could be used in a Tokamak Experimental Power Reactor for operation in the mid-1980's. The second objective is to provide a capability for further optimization of tritium fuel cycle and environmental control systems beyond that which is required for the EPR. The scale and flow rates in TSTF are close to those which have been projected for a prototype experimental power reactor (PEPR/ITR) and will permit reliable extrapolation to the conditions found in an EPR. The fuel concentrations will be the same as in an EPR. Demonstrations of individual components of the deuterium-tritium fuel cycle and of monitoring, accountability and containment systems and of a maintenance methodology will be achieved at various times in the FY 1979-80 time span. Subsequent to the individual component demonstrations--which will proceed from tests with hydrogen (and/or deuterium) through tracer levels of tritium to full operational concentrations--a complete test and demonstration of the integrated fuel processing and tritium containment facility will be performed. This will occur near the middle of FY 1981. Two options were considered for the TSTF: (1) The modification of an existing building and (2) the construction of a new facility

  15. Resonance test system

    Science.gov (United States)

    Musial, Walter [Boulder, CO; White, Darris [Superior, CO

    2011-05-31

    An apparatus (10) for applying at least one load to a specimen (12) according to one embodiment of the invention may comprise a mass (18). An actuator (20) mounted to the specimen (12) and operatively associated with the mass (18) moves the mass (18) along a linear displacement path (22) that is perpendicular to a longitudinal axis of the specimen (12). A control system (26) operatively associated with the actuator (20) operates the actuator (20) to reciprocate the mass (18) along the linear displacement path (22) at a reciprocating frequency, the reciprocating frequency being about equal to a resonance frequency of the specimen (12) in a test configuration.

  16. Defect detection in conducting materials using eddy current testing techniques

    Directory of Open Access Journals (Sweden)

    Brauer Hartmut

    2014-01-01

    Full Text Available Lorentz force eddy current testing (LET is a novel nondestructive testing technique which can be applied preferably to the identification of internal defects in nonmagnetic moving conductors. The LET is compared (similar testing conditions with the classical eddy current testing (ECT. Numerical FEM simulations have been performed to analyze the measurements as well as the identification of internal defects in nonmagnetic conductors. The results are compared with measurements to test the feasibility of defect identification. Finally, the use of LET measurements to estimate of the electrical conductors under test are described as well.

  17. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    DEFF Research Database (Denmark)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos

    2012-01-01

    The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in consecutiv...

  18. Current patch test results with the European baseline series and extensions to it from the 'European Surveillance System on Contact Allergy' network, 2007-2008

    NARCIS (Netherlands)

    Uter, Wolfgang; Aberer, Werner; Armario-Hita, José Carlos; Fernandez-Vozmediano, José M; Ayala, Fabio; Balato, Anna; Bauer, Andrea; Ballmer-Weber, Barbara; Beliauskiene, Aiste; Fortina, Anna Belloni; Bircher, Andreas; Brasch, Jochen; Chowdhury, Mahbub M U; Coenraads, Pieter-Jan; Schuttelaar, Marie-Louise; Cooper, Sue; Czarnecka-Operacz, Magda; Zmudzinska, Maria; Elsner, Peter; English, John S C; Frosch, Peter J; Fuchs, Thomas; García-Gavín, Juan; Fernández-Redondo, Virginia; Gawkrodger, David J; Giménez-Arnau, Ana; Green, Cathy M; Horne, Helen L; Johansen, Jeanne Duus; Jolanki, Riitta; Pesonen, Maria; King, Clodagh M; Krêcisz, Beata; Chomiczewska, Dorota; Kiec-Swierczynska, Marta; Larese, Francesca; Mahler, Vera; Ormerod, Anthony D; Peserico, Andrea; Rantanen, Tapio; Rustemeyer, Thomas; Sánchez-Pérez, Javier; Sansom, Jane E; Silvestre, Juan Fco; Simon, Dagmar; Spiewak, Radoslaw; Statham, Barry N; Stone, Natalie; Wilkinson, Mark; Schnuch, Axel

    BACKGROUND: The pattern of contact sensitization to the supposedly most important allergens assembled in the baseline series differs between countries, presumably at least partly because of exposure differences. Objectives. To describe the prevalence of contact sensitization to allergens tested in

  19. SPECTR System Operational Test Report

    International Nuclear Information System (INIS)

    Landman, W.H. Jr.

    2011-01-01

    This report overviews installation of the Small Pressure Cycling Test Rig (SPECTR) and documents the system operational testing performed to demonstrate that it meets the requirements for operations. The system operational testing involved operation of the furnace system to the design conditions and demonstration of the test article gas supply system using a simulated test article. The furnace and test article systems were demonstrated to meet the design requirements for the Next Generation Nuclear Plant. Therefore, the system is deemed acceptable and is ready for actual test article testing.

  20. Development and Testing of Embedded Gridding Within the Regional Ocean Modeling System: Interaction Between Near-Shore Off-Shore Currents and Material Properties

    National Research Council Canada - National Science Library

    McWilliams, James

    2003-01-01

    ...) continuing the development of the Regional Ocean Modeling System (ROMS) with respect to its hydrodynamic algorithms, physical transport parameterizations, and range of biogeochemical processes; (2...

  1. Spaceport Command and Control System Automation Testing

    Science.gov (United States)

    Hwang, Andrew

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administrations (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This large system requires high quality testing that will properly measure the capabilities of the system. Automating the test procedures would save the project time and money. Therefore, the Electrical Engineering Division at Kennedy Space Center (KSC) has recruited interns for the past two years to work alongside full-time engineers to develop these automated tests, as well as innovate upon the current automation process.

  2. Spaceport Command and Control System Automated Testing

    Science.gov (United States)

    Stein, Meriel

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administrations (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This large system requires high quality testing that will properly measure the capabilities of the system. Automating the test procedures would save the project time and money. Therefore, the Electrical Engineering Division at Kennedy Space Center (KSC) has recruited interns for the past two years to work alongside full-time engineers to develop these automated tests, as well as innovate upon the current automation process.

  3. Sizing Performance of the Newly Developed Eddy Current System

    Energy Technology Data Exchange (ETDEWEB)

    Cho, Chan Hee; Lee, Hee Jong; Yoo, Hyun Ju; Moon, Gyoon Young; Lee, Tae Hoon [Korea Hydro and Nuclear Power Co., Ltd., Daejeon (Korea, Republic of)

    2013-10-15

    This paper describes the comparison results of sizing performance for two systems. The KHNP developed a new eddy current testing system for the inspection of steam generator tubing in domestic nuclear power plants. The equivalency assessment of the newly developed system with the EPRI-qualified system was already carried out. In this paper, the comparisons of depth-sizing performance for the artificial flaws between two systems were performed. The results show that the newly developed system is in good agreement with the qualified system. Therefore, it is expected that the newly developed eddy current system can be used for the inspection of steam generator tubing in nuclear power plants. There are some non-destructive examination (NDE) methods for the inspection of components in nuclear power plants, such as ultrasonic, radiographic, eddy current testing, etc. The eddy current testing is widely used for the inspection of steam generator (SG) tubing because it offers a relatively low cost approach for high speed, large scale testing of metallic materials in high pressure and temperature engineering systems. The Korea Hydro and Nuclear Power Co., Ltd. (KHNP) developed an eddy current testing system for the inspection of steam generator tubing in nuclear power plants. This system includes not only hardware but software such as the frequency generator and data acquisition-analysis program. The foreign eddy current system developed by ZETEC is currently used for the inspection of steam generator tubing in domestic nuclear power plants. The equivalency assessment between two systems was already carried out in accordance with the EPRI steam generator examination guidelines.

  4. Reactor coolant pump testing using motor current signatures analysis

    Energy Technology Data Exchange (ETDEWEB)

    Burstein, N.; Bellamy, J.

    1996-12-01

    This paper describes reactor coolant pump motor testing carried out at Florida Power Corporation`s Crystal River plant using Framatome Technologies` new EMPATH (Electric Motor Performance Analysis and Trending Hardware) system. EMPATH{trademark} uses an improved form of Motor Current Signature Analysis (MCSA), technology, originally developed at Oak Ridge National Laboratories, for detecting deterioration in the rotors of AC induction motors. Motor Current Signature Analysis (MCSA) is a monitoring tool for motor driven equipment that provides a non-intrusive means for detecting the presence of mechanical and electrical abnormalities in the motor and the driven equipment. The base technology was developed at the Oak Ridge National Laboratory as a means for determining the affects of aging and service wear specifically on motor-operated valves used in nuclear power plant safety systems, but it is applicable to a broad range of electric machinery. MCSA is based on the recognition that an electric motor (ac or dc) driving a mechanical load acts as an efficient and permanently available transducer by sensing mechanical load variations, large and small, long-term and rapid, and converting them into variations in the induced current generated in the motor windings. The motor current variations, resulting from changes in load caused by gears, pulleys, friction, bearings, and other conditions that may change over the life of the motor, are carried by the electrical cables powering the motor and are extracted at any convenient location along the motor lead. These variations modulate the 60 Hz carrier frequency and appear as sidebands in the spectral plot.

  5. Energy Systems Test Area (ESTA). Power Systems Test Facilities

    Science.gov (United States)

    Situ, Cindy H.

    2010-01-01

    This viewgraph presentation provides a detailed description of the Johnson Space Center's Power Systems Facility located in the Energy Systems Test Area (ESTA). Facilities and the resources used to support power and battery systems testing are also shown. The contents include: 1) Power Testing; 2) Power Test Equipment Capabilities Summary; 3) Source/Load; 4) Battery Facilities; 5) Battery Test Equipment Capabilities Summary; 6) Battery Testing; 7) Performance Test Equipment; 8) Battery Test Environments; 9) Battery Abuse Chambers; 10) Battery Abuse Capabilities; and 11) Battery Test Area Resources.

  6. Sustained currents in coupled diffusive systems

    International Nuclear Information System (INIS)

    Larralde, Hernán; Sanders, David P

    2014-01-01

    Coupling two diffusive systems may give rise to a nonequilibrium stationary state (NESS) with a non-trivial persistent, circulating current. We study a simple example that is exactly soluble, consisting of random walkers with different biases towards a reflecting boundary, modelling, for example, Brownian particles with different charge states in an electric field. We obtain analytical expressions for the concentrations and currents in the NESS for this model, and exhibit the main features of the system by numerical simulation. (paper)

  7. Careful system design. Current interim results of the heat pump field test; Das Gesamtsystem sorgfaeltig auslegen. Aktuelle Zwischenergebnisse im Waermepumpen-Feldtest

    Energy Technology Data Exchange (ETDEWEB)

    Miara, Marek [Fraunhofer-Institut fuer Solare Energiesysteme ISE, Freiburg (Germany)

    2008-09-15

    How efficient are modern electric heat pumps for newly constructed single-family dwellings? This question is to be answered by the project ''Waermepumpen-Effizienz'' (heat pump efficiency), a scientific field test that started in the summer of 2006. The contribution presents first results, including the measured performance data. Further, factors were identified that interfere with the optimum operation of heat pumps. (orig.)

  8. Ship Systems Survivability Test Site

    Data.gov (United States)

    Federal Laboratory Consortium — Area for testing survivability of shipboard systems to include electrical, communications, and fire suppression. Multipurpose test range for supporting gun firing,...

  9. Automated System Tests High-Power MOSFET's

    Science.gov (United States)

    Huston, Steven W.; Wendt, Isabel O.

    1994-01-01

    Computer-controlled system tests metal-oxide/semiconductor field-effect transistors (MOSFET's) at high voltages and currents. Measures seven parameters characterizing performance of MOSFET, with view toward obtaining early indication MOSFET defective. Use of test system prior to installation of power MOSFET in high-power circuit saves time and money.

  10. Inspection system performance test procedure

    International Nuclear Information System (INIS)

    Jensen, C.E.

    1995-01-01

    This procedure establishes requirements to administer a performance demonstration test. The test is to demonstrate that the double-shell tank inspection system (DSTIS) supplied by the contractor performs in accordance with the WHC-S-4108, Double-Shell Tank Ultrasonic Inspection Performance Specification, Rev. 2-A, January, 1995. The inspection system is intended to provide ultrasonic (UT) and visual data to determine integrity of the Westinghouse Hanford Company (WHC) site underground waste tanks. The robotic inspection system consists of the following major sub-systems (modules) and components: Mobile control center; Deployment module; Cable management assembly; Robot mechanism; Ultrasonic testing system; Visual testing system; Pneumatic system; Electrical system; and Control system

  11. Automatic system for ionization chamber current measurements

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The present work describes an automatic system developed for current integration measurements at the Laboratorio de Metrologia Nuclear of Instituto de Pesquisas Energeticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design

  12. Electronic constant current and current pulse signal generator for nuclear instrumentation testing

    International Nuclear Information System (INIS)

    Brown, R.A.

    1994-01-01

    Circuitry is described for testing the ability of an intermediate range nuclear instrument to detect and measure a constant current and a periodic current pulse. The invention simulates the resistance and capacitance of the signal connection of a nuclear instrument ion chamber detector and interconnecting cable. An LED flasher/oscillator illuminates an LED at a periodic rate established by a timing capacitor and circuitry internal to the flasher/oscillator. When the LED is on, a periodic current pulse is applied to the instrument. When the LED is off, a constant current is applied. An inductor opposes battery current flow when the LED is on. 1 figures

  13. A Labview Based Leakage Current Monitoring System For HV Insulators

    Directory of Open Access Journals (Sweden)

    N. Mavrikakis

    2015-10-01

    Full Text Available In this paper, a Labview based leakage current monitoring system for High Voltage insulators is described. The system uses a general purpose DAQ system with the addition of different current sensors. The DAQ system consists of a chassis and hot-swappable modules. Through the proper design of current sensors, low cost modules operating with a suitable input range can be employed. Fully customizable software can be developed using Labview, allowing on-demand changes and incorporation of upgrades. Such a system provides a low cost alternative to specially designed equipment with the added advantage of maximum flexibility. Further, it can be modified to satisfy the specifications (technical and economical set under different scenarios. In fact, the system described in this paper has already been installed in the HV Lab of the TEI of Crete whereas a variation of it is currently in use in TALOS High Voltage Test Station.

  14. Testing of Mortar Systems

    Science.gov (United States)

    2010-03-11

    IEP /TDP) or Independent Assessment Plan (IAP), and the test item and the procedures as outlined in this TOP. The following must also be considered...Command DTIC = Defense Technical Information Center DTP = Detailed Test Plan IAP = Independent Assessment Plan IEP = Independent Evaluation Plan IPT

  15. Foucault current testing of ferritic steel fuel cans

    International Nuclear Information System (INIS)

    Stossel, A.

    1984-10-01

    The analysis of impedance involved by a Foucault current test of ferritic steel tubes, is quite different from the classical analysis which refers to non-magnetic tubes; more particularly, volume defects are considered as magnetic anomalies. Contrarily to current instructions which recommend to test the product in a satured magnetic state, it is very interesting to work with a continuous energizing field, comparatively low, corresponding to a sequenced magnetization, of which value is obtained according to the magnetic structure of the product. This analysis is useful when testing fast reactor fuel cans [fr

  16. AC over-current test results of YBCO conductor for YBCO power transformer with fault current limiting function

    International Nuclear Information System (INIS)

    Tomioka, A.; Otonari, T.; Ogata, T.; Iwakuma, M.; Okamoto, H.; Hayashi, H.; Iijima, Y.; Saito, T.; Gosho, Y.; Tanabe, K.; Izumi, T.; Shiohara, Y.

    2011-01-01

    The single-layer coils with a diameter of 250 mm and 12 turns were manufactured with YBCO tapes with a CuNi- or Cu-Tape. The AC over-current tests were carried out in subcooled liquid nitrogen at 66 K and 74 K to develop power transformers with current limiting function. The AC over-current was two to seven times larger than the I c of conductor and it was reduced to the same level of I c . The I c of model coils did not degrade. The test results showed the possibility of YBCO superconducting transformers with current limiting function. We are developing elemental technology for 66 kV/6.9 kV 20 MVA-class YBCO power transformer. The YBCO transformer is considered to have a possibility to stabilize the power system by improving function of fault current limiting. Current limiting behavior functions over critical current flows. There is a possibility that superconducting characteristic may be damaged due to increase in temperature of YBCO tapes. Therefore, we have taken a measure to combine YBCO tape with CuNi tape or Cu Tape. We manufactured model coils using these conductors and conducted the AC over-current tests. The test current was two to seven times larger than the I c of conductor and it was damped with time from its maximum value according to the generation of conductor resistance. We verified the effectiveness of current limiting characteristics. In these tests, the I c of model coil did not degrade. We consider this conductor to be able to withstand AC over-current with the function of current limiting.

  17. Direct current power delivery system and method

    Science.gov (United States)

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  18. Fermilab tevatron five refrigerator system tests

    International Nuclear Information System (INIS)

    Rode, C.; Ferry, R.; Leiniger, M.; Makara, J.; Misek, J.; Mizicko, D.; Richied, D.; Theilacker, J.

    1982-01-01

    The Fermilab Tevatron refrigeration system is described with the layout illustrated. The compressor control loops, the refrigerator control loops, and magnet control loops (two per refrigerator) are described and each illustrated. The mobile purifier is described. A five refrigerator test is presented, using two compressor buildings, satellite refrigerator concept test and the test current to the writing. The configuration of the five refrigerator test is diagramed

  19. Mobile leak testing system

    International Nuclear Information System (INIS)

    Ungr, F.

    The design and implementation are described of a mobile testing unit ULTRATEST M for helium leak tests. The equipment has been developed by Leybold-Heraeus GmbH in Cologne and is in-built in a Mercedes-Benz 208 van. The equipment is designed for the operative use in assembly and construction of nuclear power plants and its throughput is sufficient for checking the whole upper reactor block. It may also be used for removing defects of vacuum equipment requiring a high level of tightness or equally demanding equipment used in the chemical industry. Experience with the equipment is described. (B.S.)

  20. CAMAC system test module

    International Nuclear Information System (INIS)

    Dawson, W.K.; Gjovig, A.; Naivar, F.; Potter, J.; Smith, W.

    1981-01-01

    Since the CAMAC Branch Highway is used to both send information to and receive information from a CAMAC crate, faults in this highway can be difficult to recognize and diagnose. Similarly faults caused by a Crate Controller corrupting either instructions or data are difficult to distinguish from faults caused by the modules themselves. The CLIVIT (CAMAC Logic Integrity Via Interactive Testing) module is designed to largely eliminate such difficulties and ambiguities by allowing the verification of Branch Highway and Dataway transactions via an independent data communication path. The principle of operation of the CLIVIT is explained. Described are the prototype construction, testing and use

  1. Test system and method

    DEFF Research Database (Denmark)

    2012-01-01

    at a second distance from the centre, the second distance being larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged...... larger than the first distance, one or more sensors arranged at each fluid channel, wherein the sensors each comprise at least one optical detectable member, the test apparatus further comprising one or more optical sensing devices arranged for sensing the at least one optical detectable member...

  2. Medical Robots: Current Systems and Research Directions

    Directory of Open Access Journals (Sweden)

    Ryan A. Beasley

    2012-01-01

    Full Text Available First used medically in 1985, robots now make an impact in laparoscopy, neurosurgery, orthopedic surgery, emergency response, and various other medical disciplines. This paper provides a review of medical robot history and surveys the capabilities of current medical robot systems, primarily focusing on commercially available systems while covering a few prominent research projects. By examining robotic systems across time and disciplines, trends are discernible that imply future capabilities of medical robots, for example, increased usage of intraoperative images, improved robot arm design, and haptic feedback to guide the surgeon.

  3. Remote field eddy current testing of ferromagnetic tubes

    International Nuclear Information System (INIS)

    David, B.

    1990-01-01

    In order to test ferromagnetic tubes using internal probes, Intercontrole and the CEA have carried out theoretical and experimental works and developed a method to adapt the Remote Field Eddy Current technique which has been known and used for 30 years now. This document briefly recalls the basic principles of the Remote Field Eddy Current technique, the various steps of the works carried out and mainly describes examples of field inspection of ferromagnetic tubes and pipes [fr

  4. Current Hitachi knowledge engineering systems: an overview

    Energy Technology Data Exchange (ETDEWEB)

    Masui, S; Maeda, A; Masuishi, T [Hitachi, Ltd., Tokyo (Japan)

    1992-02-01

    In order to bring the knowledge engineering technology up to the practical phase, Hitachi has provided several knowledge engineering system products, including expert system building tools, knowledge acquisition tools, and many kinds of stand-alone and build-in expert systems in both the business and process control fields. In this review article, an overview of Hitachi{prime}s recent knowledge systems is described, which includes a trend analysis on recent market recognition. In addition, to introduce the Hitachi{prime}s current activities, a new product, a user interface building tool, and a new method of tuning fuzzy membership functions using a neuro-computing algorithm are also described. Furthermore, it is pointed out that not only practical tools and methodologies, but also a practical development team, including a planning section, a cooperating expert, a user section, and experienced knowledge engineers, is needed to achieve practical expert systems. 20 refs., 10 figs., 1 tab.

  5. Full Cryogenic Test of 600 A HTS Hybrid Current Leads for the LHC

    CERN Document Server

    Al-Mosawi, MK; Beduz, C; Ballarino, A; Yang, Y

    2007-01-01

    For full cryogenic test of CERN 600 A High Temperature Superconducting (HTS) current leads prior to integration into the Large Hadron Collider (LHC), a ded. facility has been designed, constructed and operated at the University of Southampton. The facility consists of purpose-built test cryostats, 20 K helium gas supply, helium gas flow and temperature control systems and quench protection system. Over 400 such leads have already been successfully tested and qualified for installation at CERN. This paper describes various design and operation aspects of the test facility and presents the detailed cryogenic test results of the CERN 600 A current leads, including steady state 20 K flow rates.

  6. Nuclear system test simulator

    International Nuclear Information System (INIS)

    Sawyer, S.D.; Hill, W.D.; Wilson, P.A.; Steiner, W.M.

    1987-01-01

    A transportable test simulator is described for a nuclear power plant. The nuclear power plant includes a control panel, a reactor having actuated rods for moving into and out of a reactor for causing the plant to operate, and a control rod network extending between the control panel and the reactor rods. The network serially transmits command words between the panel and rods, and has connecting interfaces at preselected points remote from the control panel between the control panel and rods. The test simulator comprises: a test simulator input for transport to and connection into the network at at least one interface for receiving the serial command words from the network. Each serial command includes an identifier portion and a command portion; means for processing interior of the simulator for the serial command words for identifying that portion of the power plant designated in the identifier portion and processing the word responsive to the command portion of the word after the identification; means for generating a response word responsive to the command portion; and output means for sending and transmitting the response word to the nuclear power plant at the interface whereby the control panel responds to the response word

  7. Review of Current Nuclear Vacuum System Technologies

    International Nuclear Information System (INIS)

    Carroll, M.; McCracken, J.; Shope, T.

    2003-01-01

    Nearly all industrial operations generate unwanted dust, particulate matter, and/or liquid wastes. Waste dust and particulates can be readily tracked to other work locations, and airborne particulates can be spread through ventilation systems to all locations within a building, and even vented outside the building - a serious concern for processes involving hazardous, radioactive, or nuclear materials. Several varieties of vacuum systems have been proposed and/or are commercially available for clean up of both solid and liquid hazardous and nuclear materials. A review of current technologies highlights both the advantages and disadvantages of the various systems, and demonstrates the need for a system designed to address issues specific to hazardous and nuclear material cleanup. A review of previous and current hazardous/nuclear material cleanup technologies is presented. From simple conventional vacuums modified for use in industrial operations, to systems specifically engineered for such purposes, the advantages and disadvantages are examined in light of the following criteria: minimal worker exposure; minimal secondary waste generation;reduced equipment maintenance and consumable parts; simplicity of design, yet fully compatible with all waste types; and ease of use. The work effort reviews past, existing and proposed technologies in light of such considerations. Accomplishments of selected systems are presented, including identified areas where technological improvements could be suggested

  8. Multifrequency eddy current testing of helical tubes of steam generators

    International Nuclear Information System (INIS)

    Pigeon, M.; David, B.

    1983-06-01

    In the event of a water-sodium reaction in a steam-generator of a fast breeder reactor, it is necessary to test the tubes close to the leak to evaluate the damage. In SUPERPHENIX, the tubes are about 100m long and are coiled on a dead body. This report describes the equipment and the technic to test such tubes with multifrequency eddy current technics [fr

  9. Eddy current testing probe optimization using a parallel genetic algorithm

    Directory of Open Access Journals (Sweden)

    Dolapchiev Ivaylo

    2008-01-01

    Full Text Available This paper uses the developed parallel version of Michalewicz's Genocop III Genetic Algorithm (GA searching technique to optimize the coil geometry of an eddy current non-destructive testing probe (ECTP. The electromagnetic field is computed using FEMM 2D finite element code. The aim of this optimization was to determine coil dimensions and positions that improve ECTP sensitivity to physical properties of the tested devices.

  10. Current Ground Test Options for Nuclear Thermal Propulsion (NTP)

    Science.gov (United States)

    Gerrish, Harold P., Jr.

    2014-01-01

    About 20 different NTP engines/ reactors were tested from 1959 to 1972 as part of the Rover and Nuclear Engine for Rocket Vehicle Application (NERVA) program. Most were tested in open air at test cell A or test cell C, at the Nevada Test Site (NTS). Even after serious engine breakdowns of the reactor (e.g., Phoebus 1A), the test cells were cleaned up for other engine tests. The engine test stand (ETS) was made for high altitude (approximately 1 psia) testing of an NTP engine with a flight configuration, but still had the exhaust released to open air. The Rover/NERVA program became aware of new environmental regulations which would prohibit the release of any significant quantity of radioactive particulates and noble gases into the open air. The nuclear furnace (NF-1) was the last reactor tested before the program was cancelled in 1973, but successfully demonstrated a scrubber concept on how to filter the NTP exhaust. The NF-1 was demonstrated in the summer of 1972. The NF-1 used a 44MW reactor and operated each run for approximately 90 minutes. The system cooled the hot hydrogen exhaust from the engine with a water spray before entering a particle filter. The exhaust then passed through a series of heat exchangers and water separators to help remove water from the exhaust and further reduce the exhaust temperatures. The exhaust was next prepared for the charcoal trap by passing through a dryer and effluent cooler to bring exhaust temperatures close to liquid nitrogen. At those low temperatures, most of the noble gases (e.g., Xe and Kr made from fission products) get captured in the charcoal trap. The filtered hydrogen is finally passed through a flare stack and released to the air. The concept was overall successful but did show a La plating on some surfaces and had multiple recommendations for improvement. The most recent detailed study on the NTP scrubber concept was performed by the ARES Corporation in 2006. The concept is based on a 50,000 lbf thrust engine

  11. Rip current monitoring using GPS buoy system

    Science.gov (United States)

    Song, DongSeob; Kim, InHo; Kang, DongSoo

    2014-05-01

    The occurrence of rip current in the Haeundae beach, which is one of the most famous beaches in South Korea, has been threatening beach-goers security in summer season annually. Many coastal scientists have been investigating rip currents by using field observations and measurements, laboratory measurements and wave tank experiments, and computer and numerical modeling. Rip current velocity is intermittent and may rapidly increase within minutes due to larger incoming wave groups or nearshore circulation instabilities. It is important to understand that changes in rip current velocity occur in response to changes in incoming wave height and period as well as changes in water level. GPS buoys have been used to acquire sea level change data, atmospheric parameters and other oceanic variables in sea for the purposes of vertical datum determination, tide correction, radar altimeter calibration, ocean environment and marine pollution monitoring. Therefore, we adopted GPS buoy system for an experiment which is to investigate rip current velocity; it is sporadic and may quickly upsurge within minutes due to larger arriving wave groups or nearshore flow uncertainties. In this study, for high accurate positioning of buy equipment, a Satellite Based Argumentation System DGPS data logger was deployed to investigate within floating object, and it can be acquired three-dimensional coordinate or geodetic position of buoy with continuous NMEA-0183 protocol during 24 hours. The wave height measured by in-situ hydrometer in a cross-shore array clearly increased before and after occurrence of rip current, and wave period also was lengthened around an event. These results show that wave height and period correlate reasonably well with long-shore current interaction in the Haeundae beach. Additionally, current meter data and GPS buoy data showed that rip current velocities, about 0.2 m/s, may become dangerously strong under specific conditions. Acknowledgement This research was

  12. Assessment Guide for Educators: A Content Comparison--2002 Series Test and the Current GED® Test

    Science.gov (United States)

    GED Testing Service, 2017

    2017-01-01

    This report provides a content comparison for the 2002 Series GED® test and the current GED® for the following test topic areas: (1) Mathematical Reasoning; (2) Reasoning through Language Arts; (3) Science; and (4) Social Studies.

  13. Portable Health Algorithms Test System

    Science.gov (United States)

    Melcher, Kevin J.; Wong, Edmond; Fulton, Christopher E.; Sowers, Thomas S.; Maul, William A.

    2010-01-01

    A document discusses the Portable Health Algorithms Test (PHALT) System, which has been designed as a means for evolving the maturity and credibility of algorithms developed to assess the health of aerospace systems. Comprising an integrated hardware-software environment, the PHALT system allows systems health management algorithms to be developed in a graphical programming environment, to be tested and refined using system simulation or test data playback, and to be evaluated in a real-time hardware-in-the-loop mode with a live test article. The integrated hardware and software development environment provides a seamless transition from algorithm development to real-time implementation. The portability of the hardware makes it quick and easy to transport between test facilities. This hard ware/software architecture is flexible enough to support a variety of diagnostic applications and test hardware, and the GUI-based rapid prototyping capability is sufficient to support development execution, and testing of custom diagnostic algorithms. The PHALT operating system supports execution of diagnostic algorithms under real-time constraints. PHALT can perform real-time capture and playback of test rig data with the ability to augment/ modify the data stream (e.g. inject simulated faults). It performs algorithm testing using a variety of data input sources, including real-time data acquisition, test data playback, and system simulations, and also provides system feedback to evaluate closed-loop diagnostic response and mitigation control.

  14. Modelling and simulation of eddy current non-destructive testing

    International Nuclear Information System (INIS)

    Mansir, H.; Burais, N.; Nicolas, A.

    1986-01-01

    This paper presents the practical configuration for detecting cracks in conducting materials by eddy current non destructive testing. An electromagnetic field formulation is proposed using Maxwell's relations. Geometrical and physical properties of the crack are taken into account by several models, particularly with a new finite element called ''crack element''. Modelisation is applied to sensor impedance calculation with classical numerical methods [fr

  15. [Current status and clinical application prospect of Akabane's test].

    Science.gov (United States)

    Wang, Wenjie; Du, Yanjun

    2016-06-12

    The Akabane's test is one of the meridian diagnostic methods. Compared with the current meridian diagnostic methods, it has the advantages of convenience and efficiency, but it also has several disadvantages such as the accuracy is difficult to control, the outcome interpretation is limited, etc. In this paper, the influence factors of Akabane's test were analyzed one by one, especially proposed personal opinion on outcome interpretation, which could ascertain the location and nature of disease, leading to disease syndrome. With accurate syndrome, the treatment plan could be established. The application prospect of Akabane's test was initially explored, and it was proposed that wearable automation equipment could be one of the development directions.

  16. Current trends and future development in pharmacologic stress testing

    International Nuclear Information System (INIS)

    Bae, Jin Ho; Lee, Jae Tae

    2005-01-01

    Pharmacologic stress testing for myocardial perfusion imaging is a widely used noninvasive method for the evaluation of known or suspected coronary artery disease. The use of exercise for cardiac stress has been practiced for over 60 years and clinicians are familiar with its using. However, there are inevitable situations in which exercise stress is inappropriate. A large number of patients with cardiac problems are unable to exercise to their full potential due to comorbidity such as osteoarthritis, vascular disease and pulmonary disease and a standard exercise stress test for myocardial perfusion imaging is suboptimal means for assessment of coronary artery disease. This problem has led to the development of the pharmacologic stress test and to a great increase in its popularity. All of the currently used pharmacologic agents have well-documented diagnostic value. This review deals the physiological actions, clinical protocols, safety, nuclear imaging applications of currently available stress agents and future development of new vasodilating agents

  17. Test System Impact on System Availability

    DEFF Research Database (Denmark)

    Pau, L. F.

    1987-01-01

    The specifications are presented for an imperfect automatic test system (ATS) (test frequency distribution, reliability, false alarm rate, nondetection rate) in order to account for the availability, readiness, mean time between unscheduled repairs (MTBUR), reliability, and maintenance of the sys......The specifications are presented for an imperfect automatic test system (ATS) (test frequency distribution, reliability, false alarm rate, nondetection rate) in order to account for the availability, readiness, mean time between unscheduled repairs (MTBUR), reliability, and maintenance...... of the system subject to monitoring and test. A time-dependent Markov model is presented, and applied in three cases, with examples of numerical results provided for preventive maintenance decisions, design of an automatic test system, buffer testing in computers, and data communications....

  18. Conserved vector current test/second class current search in the A = 8 isotriplet

    International Nuclear Information System (INIS)

    Snover, K.A.; Schagen, J.P.S. van; Storm, D.W.; Kelly, M.P.

    2002-01-01

    A new experiment is underway to make a precision determination of the isovector M1 and E2 decays of the 2 + isobaric analog resonance doublet in 8 Be for the purpose of an improved CVC/SCC test in the A = 8 isotriplet. Assuming CVC holds, our current sensitivity for SCC is at the level of 5% of weak magnetism. (author)

  19. Testing of full size high current superconductors in SULTAN III

    Science.gov (United States)

    Blau, B.; Rohleder, I.; Vecsey, G.; Pasotti, G.; Ricci, M. V.; Sacchetti, N.; Bruzzone, P.; Katheder, H.; Mitchell, N.; Bessette, D.

    1994-07-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 mu V/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb3Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb3Sn conductors in the 8 - 11 T range for temperatures between 4.5 K and 11 K. Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb3Sn conductors after heat treatment is reported, together with some measurements of the joint resistance.

  20. Testing of full size high current superconductors in SULTAN III

    International Nuclear Information System (INIS)

    Blau, B.; Rohleder, I.; Vecsey, G.

    1994-01-01

    The high field test facility SULTAN III in operation at PSI/Switzerland tests full size industrial prototype superconductors for fusion applications such as ITER. The facility provides a background field of up to 11 T over a length of 58 cm. A 50 kA superconducting transformer works as a very low noise current source which allows a criterion of 0.1 μV/cm to determine the superconducting to normal transition. Three 3.6 m long cable-in-conduit conductors based on both NbTi and Nb 3 Sn, developed by different manufacturers, suitable for the central solenoid and toroidal field coils of ITER, have been tested so far. This paper presents the results of extensive measurements of critical current and current sharing temperature of the Nb 3 Sn conductors in the 8--11 T range for temperatures between 4.5 K and 11 K Voltage versus current curves have been analyzed with respect to the n value. The manufacturing of a high quality joint between two Nb 3 Sn conductors after heat treatment is reported, together with some measurements of the joint resistance

  1. Eddy current test of fin tubes for a heat exchanger

    International Nuclear Information System (INIS)

    KIm, Young Joo; Lee, Se Kyung; Chung, Min Hwa

    1992-01-01

    Eddy current probes were designed for the test of fin tubes. Fin tubes, often used for heat exchangers, have uneven outer and inner surfaces to enhance the heat emission. The surface roughness make it difficult to detect flaws employing eddy current test(ECT). In order to overcome the difficulties we performed two types of works, one is the delopment of ECT probes, and the other is the signal processing including fast Fourier transform and digital filtering. In the development of ECT probes, we adopted empirical design method. Our ECT probes for fin tubes are inside diameter type. And we are specially concerned about geometric features such as the widths of the coils composing an ECT probe. We fabricated four probes with various coil widths. Eddy current test was performed using those ECT probes on specimens with artificial flaws. After analyzing the output signals, we found that, in order for the effective testing, the width of a coil should be determined considering the pitch of the fins of a tube. And we also learned that the frequency filtering could improve the s/n ratio.

  2. Fault tolerant system based on IDDQ testing

    Science.gov (United States)

    Guibane, Badi; Hamdi, Belgacem; Mtibaa, Abdellatif; Bensalem, Brahim

    2018-06-01

    Offline test is essential to ensure good manufacturing quality. However, for permanent or transient faults that occur during the use of the integrated circuit in an application, an online integrated test is needed as well. This procedure should ensure the detection and possibly the correction or the masking of these faults. This requirement of self-correction is sometimes necessary, especially in critical applications that require high security such as automotive, space or biomedical applications. We propose a fault-tolerant design for analogue and mixed-signal design complementary metal oxide (CMOS) circuits based on the quiescent current supply (IDDQ) testing. A defect can cause an increase in current consumption. IDDQ testing technique is based on the measurement of power supply current to distinguish between functional and failed circuits. The technique has been an effective testing method for detecting physical defects such as gate-oxide shorts, floating gates (open) and bridging defects in CMOS integrated circuits. An architecture called BICS (Built In Current Sensor) is used for monitoring the supply current (IDDQ) of the connected integrated circuit. If the measured current is not within the normal range, a defect is signalled and the system switches connection from the defective to a functional integrated circuit. The fault-tolerant technique is composed essentially by a double mirror built-in current sensor, allowing the detection of abnormal current consumption and blocks allowing the connection to redundant circuits, if a defect occurs. Spices simulations are performed to valid the proposed design.

  3. Device for ultrasonic and eddy current testing of bolts

    International Nuclear Information System (INIS)

    Hromek, J.; Kaspar, P.

    1989-01-01

    The device provides pivoting fitting of the bolt of a WWER reactor steam generator while ultrasonic and eddy current probes are brought near. The bolt under study is clamped between a drive funnel and a securing cone. The eddy current probes are adjusted using guide arms to the point requested and are fitted over the bolt such as for their thread segments to engage the bolt thread. The ultrasonic transducers are then adjusted to the required point. The device can be used for testing bolts of a thread size from M54x5 and a maximum length of 600 mm. (J.B.). 1 fig

  4. Electrical short circuit and current overload tests on aircraft wiring

    Science.gov (United States)

    Cahill, Patricia

    1995-01-01

    The findings of electrical short circuit and current overload tests performed on commercial aircraft wiring are presented. A series of bench-scale tests were conducted to evaluate circuit breaker response to overcurrent and to determine if the wire showed any visible signs of thermal degradation due to overcurrent. Three types of wire used in commercial aircraft were evaluated: MIL-W-22759/34 (150 C rated), MIL-W-81381/12 (200 C rated), and BMS 1360 (260 C rated). A second series of tests evaluated circuit breaker response to short circuits and ticking faults. These tests were also meant to determine if the three test wires behaved differently under these conditions and if a short circuit or ticking fault could start a fire. It is concluded that circuit breakers provided reliable overcurrent protection. Circuit breakers may not protect wire from ticking faults but can protect wire from direct shorts. These tests indicated that the appearance of a wire subjected to a current that totally degrades the insulation looks identical to a wire subjected to a fire; however the 'fire exposed' conductor was more brittle than the conductor degraded by overcurrent. Preliminary testing indicates that direct short circuits are not likely to start a fire. Preliminary testing indicated that direct short circuits do not erode insulation and conductor to the extent that ticking faults did. Circuit breakers may not safeguard against the ignition of flammable materials by ticking faults. The flammability of materials near ticking faults is far more important than the rating of the wire insulation material.

  5. Addressing Circuitous Currents MVDC Power Systems Protection

    Science.gov (United States)

    2017-12-31

    Addressing Circuitous Currents MVDC Power Systems Protection 5b. GRANT NUMBER N00014-16-1-3113 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR($) Sd. PROJECT NUMBER...efficiency. A challenge with DC distribution is electrical protection . Z-source DC breakers alt! an pti n b&i g cvr.sidcrcd and this w rk ~xplores...zonal distribution, electric ship 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT u u u uu 18. NUMBER

  6. FPGAs and wavelets on circuit testing based on current signal measurements

    International Nuclear Information System (INIS)

    Pouros, Sotirios; Vassios, Vassilios; Manolakis, Dimitrios; Bamnios, Georgios; Papakostas, Dimitrios K.; Hatzopoulos, Alkis A.; Hristov, Valentin

    2015-01-01

    The research team designed and implemented a prototype testing system using FPGAs, where test methods for analog and digital (mixed) electronics using wavelets can be incorporated. The prototype has been evaluated and the results are promising. Moreover, the usability and verification of the system’s functionality are presented. The current sensing unit is described in detail. The new automated fault testing system incorporates reconfigurability and parallel processing capabilities.

  7. Eddy Current Testing for Detecting Small Defects in Thin Films

    Science.gov (United States)

    Obeid, Simon; Tranjan, Farid M.; Dogaru, Teodor

    2007-03-01

    Presented here is a technique of using Eddy Current based Giant Magneto-Resistance sensor (GMR) to detect surface and sub-layered minute defects in thin films. For surface crack detection, a measurement was performed on a copper metallization of 5-10 microns thick. It was done by scanning the GMR sensor on the surface of the wafer that had two scratches of 0.2 mm, and 2.5 mm in length respectively. In another experiment, metal coatings were deposited over the layers containing five defects with known lengths such that the defects were invisible from the surface. The limit of detection (resolution), in terms of defect size, of the GMR high-resolution Eddy Current probe was studied using this sample. Applications of Eddy Current testing include detecting defects in thin film metallic layers, and quality control of metallization layers on silicon wafers for integrated circuits manufacturing.

  8. CMIF ECLS system test findings

    Science.gov (United States)

    Schunk, Richard G.; Carrasquillo, Robyn L.; Ogle, Kathyrn Y.; Wieland, Paul O.; Bagdigian, Robert M.

    1989-01-01

    During 1987 three Space Station integrated Environmental Control and Life Support System (ECLSS) tests were conducted at the Marshall Space Flight Center (MSFC) Core Module Integration Facility (CMIF) as part of the MSFC ECLSS Phase II test program. The three tests ranged in duration from 50 to 150 hours and were conducted inside of the CMIF module simulator. The Phase II partial integrated system test configuration consisted of four regenerative air revitalization subsystems and one regenerative water reclamation subsystem. This paper contains a discussion of results and lessons learned from the Phase II test program. The design of the Phase II test configuration and improvements made throughout the program are detailed. Future plans for the MSFC CMIF test program are provided, including an overview of planned improvements for the Phase III program.

  9. Current and prospective fuel test programmes in the MIR reactor

    Energy Technology Data Exchange (ETDEWEB)

    Izhutov, A.L.; Burukin, A.V.; Iljenko, S.A.; Ovchinnikov, V.A.; Shulimov, V.N.; Smirnov, V.P. [State Scientific Centre of Russia Research Institute of Atomic Reactors, Ulyanovsk region (Russian Federation)

    2007-07-01

    MIR reactor is a heterogeneous thermal reactor with a moderator and a reflector made of metal beryllium, it has a channel-type design and is placed in a water pool. MIR reactor is mainly designed for testing fragments of fuel elements and fuel assemblies (FA) of different nuclear power reactor types under normal (stationary and transient) operating conditions as well as emergency situations. At present six test loop facilities are being operated (2 PWR loops, 2 BWR loops and 2 steam coolant loops). The majority of current fuel tests is conducted for improving and upgrading the Russian PWR fuel, these tests involve issues such as: -) long term tests of short-size rods with different modifications of cladding materials and fuel pellets; -) further irradiation of power plant re-fabricated and full-size fuel rods up to achieving 80 MW*d/kg U; -) experiments with leaking fuel rods at different burnups and under transient conditions; -) continuation of the RAMP type experiments at high burnup of fuel; and -) in-pile tests with simulation of LOCA and RIA type accidents. Testing of the LEU (low enrichment uranium) research reactor fuel is conducted within the framework of the RERTR programme. Upgrading of the gas cooled and steam cooled loop facilities is scheduled for testing the HTGR fuel and sub-critical water-cooled reactor, correspondingly. The present paper describes the major programs of the WWER high burn-up fuel behavior study in the MIR reactor, capabilities of the applied techniques and some results of the performed irradiation tests. (authors)

  10. A New Current Drogue System for Remotely Monitoring Shelf Current Circulation

    Science.gov (United States)

    Klemas, V. (Principal Investigator); Davis, G.; Whelan, W.; Tornatore, G.

    1975-01-01

    The author has identified the following significant results. An ocean current drogue system was developed for use in the coastal zone and continental shelf region. The method features an extremely simple radiosonde device whose position is determined from a pair of cooperative shore stations. These ocean sondes follow the tradition of the atmospheric radiosonde in that they are economically disposable at the end of their mission. The system was successfully tested in a number of environments, including the North Atlantic in two winter coastal storms. Tracking to the edge of the Baltimore and Wilmington trenches was achieved. The drogue system is being used in conjunction with remote sensing aircraft and satellites to chart current circulation at ocean waste disposal sites 40 miles off Delaware's coast.

  11. Space Fission System Test Effectiveness

    International Nuclear Information System (INIS)

    Houts, Mike; Schmidt, Glen L.; Van Dyke, Melissa; Godfroy, Tom; Martin, James; Bragg-Sitton, Shannon; Dickens, Ricky; Salvail, Pat; Harper, Roger

    2004-01-01

    Space fission technology has the potential to enable rapid access to any point in the solar system. If fission propulsion systems are to be developed to their full potential, however, near-term customers need to be identified and initial fission systems successfully developed, launched, and utilized. One key to successful utilization is to develop reactor designs that are highly testable. Testable reactor designs have a much higher probability of being successfully converted from paper concepts to working space hardware than do designs which are difficult or impossible to realistically test. ''Test Effectiveness'' is one measure of the ability to realistically test a space reactor system. The objective of this paper is to discuss test effectiveness as applied to the design, development, flight qualification, and acceptance testing of space fission systems. The ability to perform highly effective testing would be particularly important to the success of any near-term mission, such as NASA's Jupiter Icy Moons Orbiter, the first mission under study within NASA's Project Prometheus, the Nuclear Systems Program

  12. Overview of Current Turbine Aerodynamic Analysis and Testing at MSFC

    Science.gov (United States)

    Griffin, Lisa W.; Hudson, Susan T.; Zoladz, Thomas F.

    1999-01-01

    An overview of the current turbine aerodynamic analysis and testing activities at NASA/Marshall Space Flight Center (MSFC) is presented. The presentation is divided into three areas. The first area is the three-dimensional (3D), unsteady Computational Fluid Dynamics (CFD) analysis of the Fastrac turbine. Results from a coupled nozzle, blade, and exit guide vane analysis and from an uncoupled nozzle and coupled blade and exit guide vane will be presented. Unsteady pressure distributions, frequencies, and exit profiles from each analysis will be compared and contrasted. The second area is the testing and analysis of the Space Shuttle Main Engine (SSME) High Pressure Fuel Turbopump (HPFTP) turbine with instrumented first stage blades. The SSME HPFTP turbine was tested in air at the MSFC Turbine Test Equipment (TTE). Pressure transducers were mounted on the first stage blades. Unsteady, 3D CFD analysis was performed for this geometry and flow conditions. A sampling of the results will be shown. The third area is a status of the Turbine Performance Optimization task. The objective of this task is to improve the efficiency of a turbine for potential use on a next generation launch vehicle. This task includes global optimization for the preliminary design, detailed optimization for blade shapes and spacing, and application of advanced CFD analysis. The final design will be tested in the MSFC TTE.

  13. The use of eddy current testing for nuclear fuel rods cladding evaluation

    International Nuclear Information System (INIS)

    Silva Junior, Silverio F. da; Alencar, Donizete A.; Brito, Mucio Jose D. de

    2007-01-01

    Nuclear fuel rods cladding must be tested after their manufacture and during their operational life. This paper describes a study about the use of eddy current test method as a nondestructive tool for nuclear fuel rods cladding evaluation. The experiments were carried out using two different probes: an external probe and an internal probe. The main goal was to verify the sensitivity of the eddy current test system, to develop calibration and reference standards and to establish the main capabilities and limitations presented by this test method for this application. (author)

  14. Programmable automated transistor test system

    International Nuclear Information System (INIS)

    Truong, L.V.; Sundberg, G.R.

    1986-01-01

    The paper describes a programmable automated transistor test system (PATTS) and its utilization to evaluate bipolar transistors and Darlingtons, and such MOSFET and special types as can be accommodated with the PATTS base-drive. An application of a pulsed power technique at low duty cycles in a non-destructive test is used to examine the dynamic switching characteristic curves of power transistors. Data collection, manipulation, storage, and output are operator interactive but are guided and controlled by the system software. In addition a library of test data is established on disks, tapes, and hard copies for future reference

  15. Availability of periodically tested systems

    International Nuclear Information System (INIS)

    Signoret, J.P.

    1979-01-01

    There is at the present time a need in accurate models to asess the availability of periodically tested stand-by systems. This paper shows how to improve the well known 'saw-tooth curve' model in order to take into account various reliability parameters. A model is developed to assess the pointwise and the mean availabilities of periodically tested stand-by systems. Exact and approxination formulae are given. In addition, the model developed herein leads to optimize the test interval in order to minimize the mean unavailability. A safety diesel in a nuclear power plant is given as an example

  16. Surface flaw evaluation by vectorized eddy current testing image

    International Nuclear Information System (INIS)

    Endo, Hisashi; Takagi, Toshiyuki

    2006-01-01

    A method of eddy current testing (ECT) data mapping for surface breaking evaluation is studied. The multicoil ECT probe utilized in this paper consists of Transmit-Receive (TR) type sensors as array elements to obtain the information on crack directions. Switching two directional scans, U- and T- modes, gives two-dimensional vector mapping as ECT images. The ECT signals of the TR type sensor also give the information on crack directions from their variation displayed on the complex number plane. Extracting a complex number component of the signals makes it possible to visualize directions of numerically simulated proximate EDM slits. (author)

  17. Pathophysiology of recent advances in current thyroid function testing

    International Nuclear Information System (INIS)

    Hesch, R.D.

    1977-01-01

    In the first chapter I have discussed thyroid function and thyroid status which is determined by thyroid gland function in secreting T4 and peripheral biotransformation of T4. The accuracy of a current in-vitro diagnostic strategy allows high reliability in clinical routine. More recent test procedures for iodothyronines and immunological phenomena need further evaluation. In another chapter the biotransformation of T4 to bioactive and regulatory iodothyronines with respect to possible clinical implications is discussed. Finally, the role of TBG for interpration of T4 and T3 concentrations is determined and more attention directed to its functional heterogeneity. (orig.) [de

  18. Programmable, automated transistor test system

    Science.gov (United States)

    Truong, L. V.; Sundburg, G. R.

    1986-01-01

    A programmable, automated transistor test system was built to supply experimental data on new and advanced power semiconductors. The data will be used for analytical models and by engineers in designing space and aircraft electric power systems. A pulsed power technique was used at low duty cycles in a nondestructive test to examine the dynamic switching characteristic curves of power transistors in the 500 to 1000 V, 10 to 100 A range. Data collection, manipulation, storage, and output are operator interactive but are guided and controlled by the system software.

  19. Arrester Resistive Current Measuring System Based on Heterogeneous Network

    Science.gov (United States)

    Zhang, Yun Hua; Li, Zai Lin; Yuan, Feng; Hou Pan, Feng; Guo, Zhan Nan; Han, Yue

    2018-03-01

    Metal Oxide Arrester (MOA) suffers from aging and poor insulation due to long-term impulse voltage and environmental impact, and the value and variation tendency of resistive current can reflect the health conditions of MOA. The common wired MOA detection need to use long cables, which is complicated to operate, and that wireless measurement methods are facing the problems of poor data synchronization and instability. Therefore a novel synchronous measurement system of arrester current resistive based on heterogeneous network is proposed, which simplifies the calculation process and improves synchronization, accuracy and stability and of the measuring system. This system combines LoRa wireless network, high speed wireless personal area network and the process layer communication, and realizes the detection of arrester working condition. Field test data shows that the system has the characteristics of high accuracy, strong anti-interference ability and good synchronization, which plays an important role in ensuring the stable operation of the power grid.

  20. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  1. Development of Final Running Test System for Digital Systems

    International Nuclear Information System (INIS)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok

    2016-01-01

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed

  2. Development of Final Running Test System for Digital Systems

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Kwang-Dae; Lee, Eui-Jong; Lim, Hee-Taek; Kim, Min-Seok [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2016-10-15

    In nuclear industry, the newly designed systems to upgrade are qualified to meet IEEE standards and the regulatory guidelines for their functions, performance and reliability requirements. Failure Mode and Effect Analysis, Fault Tree Analysis, and Hazard Analysis have been used to improve the reliability of the control system. To ensure the completeness of the software, the verification and validation processes are carried out during the development process. In spite of the many efforts depending on the analysis and procedures, there are limitations to improve the reliability. The lessons learned from the currently installed system failures show the incompleteness of the final integration test. The current point-to-point and logic-to-logic separate test procedures manually performed by the engineers can cause some procedures missed and have effects on the critical functions. The design processes of the digital systems are met in accordance with the international standards and regulatory guidelines. The lessons learned from the failures of the running digital systems showed the limitations of the current verification and validation efforts. The various improvements and attempts have been considered including the expert review processes and the completeness of the test. In this paper, the Final Running Test Method evaluating the completeness of the digital system using the control patterns and the Test System Architecture are proposed.

  3. Predictability of the California Current System

    Science.gov (United States)

    Miller, Arthur J.; Chereskin, T.; Cornuelle, B. D.; Niiler, P. P.; Moisan, J. R.; Lindstrom, Eric (Technical Monitor)

    2001-01-01

    The physical and biological oceanography of the Southern California Bight (SCB), a highly productive subregion of the California Current System (CCS) that extends from Point Conception, California, south to Ensenada, Mexico, continues to be extensively studied. For example, the California Cooperative Oceanic Fisheries Investigations (CalCOFI) program has sampled this region for over 50 years, providing an unparalleled time series of physical and biological data. However, our understanding of what physical processes control the large-scale and mesoscale variations in these properties is incomplete. In particular, the non-synoptic and relatively coarse spatial sampling (70km) of the hydrographic grid does not completely resolve the mesoscale eddy field (Figure 1a). Moreover, these unresolved physical variations exert a dominant influence on the evolution of the ecosystem. In recent years, additional datasets that partially sample the SCB have become available. Acoustic Doppler Current Profiler (ADCP) measurements, which now sample upper-ocean velocity between stations, and sea level observations along TOPEX tracks give a more complete picture of the mesoscale variability. However, both TOPEX and ADCP are well-sampled only along the cruise or orbit tracks and coarsely sampled in time and between tracks. Surface Lagrangian drifters also sample the region, although irregularly in time and space. SeaWiFS provides estimates of upper-ocean chlorophyll-a (chl-alpha), usually giving nearly complete coverage for week-long intervals, depending on cloud coverage. Historical ocean color data from the Coastal Zone Color Scanner (CZCS) has been used extensively to determine phytoplankton patterns and variability, characterize the primary production across the SCB coastal fronts, and describe the seasonal and interannual variability in pigment concentrations. As in CalCOFI, these studies described much of the observed structures and their variability over relatively large space and

  4. Design Aspects and Test of an Inductive Fault Current Limiter

    Directory of Open Access Journals (Sweden)

    Arsénio Pedro

    2014-05-01

    Full Text Available Magnetic shielding inductive fault current limiters with high temperature superconducting tapes are considered as emerging devices that provide technology for the advent of modern power grids. The development of such limiters requires magnetic iron cores and leads to several design challenges regarding the constitutive parts of the limiter, namely the primary and secondary windings. Preliminary tests in a laboratory scale prototype have been carried out considering an assembly designed for simplicity in which the optimization of the magnetic coupling between the primary and secondary was not the main focus. This work addresses the design configuration of an inductive current limiter prototype regarding the assembly of the primary and secondary windings in the core. The prototype is based on a closed magnetic core wound by a primary, built from a normal electric conductor, and a short-circuited secondary, built from first generation superconducting tape. Four different design configurations are considered. Through experimental tests, the performance of such prototype is discussed and compared, in terms of normal and fault operation regimes. The results show that all the configurations assure effective magnetic shielding at normal operation regime, however, at fault operation regime, there are differences among configurations.

  5. The TS 600: automatic control system for eddy currents

    International Nuclear Information System (INIS)

    Poulet, J.P.

    1986-10-01

    In the scope of fabrication and in service inspection of the PWR steam generator tubing bendle, FRAMATOME developed an automatic Eddy Current testing system: TS600. Based on a mini-computer, TS600 allows to digitize, to store and to process data in various ways, so it is possible to perform several kinds of inspection: conventional inservice inspection, roll area profilometry...... TS600 can also be used to develop new methods of examination [fr

  6. Performance demonstration tests for eddy current inspection of steam generator tubing

    International Nuclear Information System (INIS)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given

  7. Performance demonstration tests for eddy current inspection of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kurtz, R.J.; Heasler, P.G.; Anderson, C.M.

    1996-05-01

    This report describes the methodology and results for development of performance demonstration tests for eddy current (ET) inspection of steam generator tubes. Statistical test design principles were used to develop the performance demonstration tests. Thresholds on ET system inspection performance were selected to ensure that field inspection systems would have a high probability of detecting and and correctly sizing tube degradation. The technical basis for the ET system performance thresholds is presented in detail. Statistical test design calculations for probability of detection and flaw sizing tests are described. A recommended performance demonstration test based on the design calculations is presented. A computer program for grading the probability of detection portion of the performance demonstration test is given.

  8. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald; Liever, Peter; Nielsen, Tanner

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test, conducted at Marshall Space Flight Center. The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  9. Space Launch System Scale Model Acoustic Test Ignition Overpressure Testing

    Science.gov (United States)

    Nance, Donald K.; Liever, Peter A.

    2015-01-01

    The overpressure phenomenon is a transient fluid dynamic event occurring during rocket propulsion system ignition. This phenomenon results from fluid compression of the accelerating plume gas, subsequent rarefaction, and subsequent propagation from the exhaust trench and duct holes. The high-amplitude unsteady fluid-dynamic perturbations can adversely affect the vehicle and surrounding structure. Commonly known as ignition overpressure (IOP), this is an important design-to environment for the Space Launch System (SLS) that NASA is currently developing. Subscale testing is useful in validating and verifying the IOP environment. This was one of the objectives of the Scale Model Acoustic Test (SMAT), conducted at Marshall Space Flight Center (MSFC). The test data quantifies the effectiveness of the SLS IOP suppression system and improves the analytical models used to predict the SLS IOP environments. The reduction and analysis of the data gathered during the SMAT IOP test series requires identification and characterization of multiple dynamic events and scaling of the event waveforms to provide the most accurate comparisons to determine the effectiveness of the IOP suppression systems. The identification and characterization of the overpressure events, the waveform scaling, the computation of the IOP suppression system knockdown factors, and preliminary comparisons to the analytical models are discussed.

  10. Experience of 12 kA / 16 V SMPS during the HTS Current Leads Test

    Science.gov (United States)

    Panchal, P.; Christian, D.; Panchal, R.; Sonara, D.; Purwar, G.; Garg, A.; Nimavat, H.; Singh, G.; Patel, J.; Tanna, V.; Pradhan, S.

    2017-04-01

    As a part of up gradation plans in SST-1 Tokamak, one pair of 3.3 kA rated prototype hybrid current leads were developed using Di-BSCCO as High Temperature Superconductors (HTS) and the copper heat exchanger. In order to validate the manufacturing procedure prior to go for series production of such current leads, it was recommended to test these current leads using dedicated and very reliable DC switch mode power supply (SMPS). As part of test facility, 12 kA, 16 VDC programmable SMPS was successfully installed, commissioned and tested. This power supply has special features such as modularity, N+1 redundancy, very low ripple voltage, precise current measurements with Direct Current Current Transformer, CC/CV modes with auto-crossover and auto-sequence programming. As a part of acceptance of this converter, A 5.8 mΩ water-cooled resistive dummy load and PLC based SCADA system is designed, developed for commissioning of power supply. The same power supply was used for the testing of the prototype HTS current leads. The paper describes the salient features and experience of state-of-art of power supply and results obtained from this converter during the HTS current leads test.

  11. Current-potential characteristics of electrochemical systems

    Energy Technology Data Exchange (ETDEWEB)

    Battaglia, Vincent S. [Univ. of California, Berkeley, CA (United States)

    1993-07-01

    This dissertation contains investigations in three distinct areas. Chapters 1 and 2 provide an analysis of the effects of electromagnetic phenomena during the initial stages of cell discharge. Chapter 1 includes the solution to Maxwell`s equations for the penetration of the axial component of an electric field into an infinitely long cylindrical conductor. Chapter 2 contains the analysis of the conductor included in a radial circuit. Chapter 3 provides a complete description of the equations that describe the growth of an oxide film. A finite difference program was written to solve the equations. The system investigated is the iron/iron oxide in a basic, aqueous solution. Chapters 4 and 5 include the experimental attempts for replacing formaldehyde with an innocuous reducing agent for electroless deposition. In chapter 4, current-versus-voltage curves are provided for a sodium thiosulfate bath in the presence of a copper disk electrode. Also provided are the cathodic polarization curves of a copper/EDTA bath in the presence of a copper electrode. Chapter 5 contains the experimental results of work done with sodium hypophosphite as a reducing agent. Mixed-potential-versus-time curves for solutions containing various combinations of copper sulfate, nickel chloride, and hypophosphite in the presence of a palladium disk electrode provide an indication of the reducing power of the solutions.

  12. Quality assurance testing of acoustic doppler current profiler transform matrices

    Science.gov (United States)

    Armstrong, Brandy; Fulford, Janice M.; Thibodeaux, Kirk G.

    2015-01-01

    The U.S. Geological Survey (USGS) Hydrologic Instrumentation Facility (HIF) is nationally responsible for the design, testing, evaluation, repair, calibration, warehousing, and distribution of hydrologic instrumentation in use within the USGS Water Mission Area (WMA). The HIF's Hydraulic Laboratory has begun routine quality assurance (QA) testing and documenting the performance of every USGS WMA acoustic Doppler current profiler (ADCP) used for making velocity and discharge measurements. All existing ADCPs are being registered and tracked in a database maintained by the HIF, and called for QA checks in the HIF's Hydraulic Laboratory on a 3- year cycle. All new ADCPs purchased directly from the manufacturer as well as ADCPs sent to the HIF or the manufacturer for repair are being registered and tracked in the database and QA checked in the laboratory before being placed into service. Meters failing the QA check are sent directly to the manufacturer for repairs and rechecked by HIF or removed from service. Although this QA program is specific to the SonTek1 and Teledyne RD Instruments1, ADCPs most commonly used within the WMA, it is the intent of the USGS Office of Surface Water and the HIF to expand this program to include all bottom tracking ADCPs as they become available and more widely used throughout the WMA. As part of the HIF QA process, instruments are inspected for physical damage, the instrument must pass the ADCP diagnostic self-check tests, the temperature probe must be within ± 2 degrees Celsius of a National Institute of Standards and Technology traceable reference thermometer and the distance made good over a fixed distance must meet the manufacturer's specifications (+/-0.25% or +/-1% difference). The transform matrix is tested by conducting distance-made-good (DMG) tests comparing the straight-line distance from bottom tracking to the measured tow-track distance. The DMG test is conducted on each instrument twice in the forward and reverse

  13. Non-destructive testing. The current state of standards and qualification and certification for leak testing

    International Nuclear Information System (INIS)

    Tamura, Yoshikazu

    2011-01-01

    Domestic standards of the leak testing are enacted as one of Japan Industrial Standards. The conformity is advanced between these domestic standards and ISO (International Organization for Standardization) standard. ISO9712 (Non-destructive testing-Qualification and certification of personnel) was revised to include the leak testing of qualification and certification in 2005. The preparation working group of qualification and certification for leak testing is planning start aiming at the system in one and a half years. (author)

  14. Detection of foreign objects using bobbin probe eddy current test

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Hee Sung; Kweon, Young Ho; Lee, Dong Ha; Shin, Wook Jo; Yim, Chan Ki [ECT Group, Sae-An Engineering Corporation, Seoul (Korea, Republic of)

    2016-08-15

    Residual foreign objects at the secondary side (top of the tubesheet and tube support plates) of a steam generator are likely to cause a leak by causing wear in the tube. The extent of wear is significantly affected by the material, shape, and size of the foreign object, and the corrosion properties of the tube. The presence of foreign objects at the top of the tubesheet and tube support plates has been identified using remote visual inspection methods such as the foreign object search and retrieval and eddy current test (ECT). The detection of the residual foreign object at the secondary side of a steam generator has limitations that depend on the material properties and the condition of contact with the tube. In this study, which is vertical and horizontal from the upper tubesheet, the corresponding bobbin ECT signals were collected and analyzed to measure its ability to detect foreign objects.

  15. Intense relativistic electron beam injector system for tokamak current drive

    International Nuclear Information System (INIS)

    Bailey, V.L.; Creedon, J.M.; Ecker, B.M.; Helava, H.I.

    1983-01-01

    We report experimental and theoretical studies of an intense relativistic electron beam (REB) injection system designed for tokamak current drive experiments. The injection system uses a standard high-voltage pulsed REB generator and a magnetically insulated transmission line (MITL) to drive an REB-accelerating diode in plasma. A series of preliminary experiments has been carried out to test the system by injecting REBs into a test chamber with preformed plasma and applied magnetic field. REBs were accelerated from two types of diodes: a conventional vacuum diode with foil anode, and a plasma diode, i.e., an REB cathode immersed in the plasma. REB current was in the range of 50 to 100 kA and REB particle energy ranged from 0.1 to 1.0 MeV. MITL power density exceeded 10 GW/cm 2 . Performance of the injection system and REB transport properties is documented for plasma densities from 5 x 10 12 to 2 x 10 14 cm -3 . Injection system data are compared with numerical calculations of the performance of the coupled system consisting of the generator, MITL, and diode

  16. TESTING CPT SYMMETRY WITH CURRENT AND FUTURE CMB MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Li, Si-Yu; Zhang, Xinmin [Theory Division, Institute of High Energy Physics, Chinese Academy of Science, P.O. Box 918-4, Beijing 100049 (China); Xia, Jun-Qing; Li, Hong [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Science, P.O. Box 918-3, Beijing 100049 (China); Li, Mingzhe, E-mail: xiajq@ihep.ac.cn [Interdisciplinary Center for Theoretical Study, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2015-02-01

    In this paper, we use the current and future cosmic microwave background (CMB) experiments to test the Charge-Parity-Time Reversal (CPT) symmetry. We consider a CPT-violating interaction in the photon sector L{sub cs}∼p{sub μ}A{sub ν} F-tilde {sup μν}, which gives rise to a rotation of the polarization vectors of the propagating CMB photons. By combining the 9 yr WMAP, BOOMERanG 2003, and BICEP1 observations, we obtain the current constraint on the isotropic rotation angle α-bar =−2.12±1.14 (1σ), indicating that the significance of the CPT violation is about 2σ. Here, we particularly take the systematic errors of CMB measurements into account. Then, we study the effects of the anisotropies of the rotation angle [Δα( n-hat )] on the CMB polarization power spectra in detail. Due to the small effects, the current CMB polarization data cannot constrain the related parameters very well. We obtain the 95% C.L. upper limit of the variance of the anisotropies of the rotation angle C {sup α}(0) < 0.035 from all of the CMB data sets. More interestingly, including the anisotropies of rotation angle could lower the best-fit value of r and relax the tension on the constraints of r between BICEP2 and Planck. Finally, we investigate the capabilities of future Planck polarization measurements on α-bar and Δα( n-hat ). Benefited from the high precision of Planck data, the constraints of the rotation angle can be significantly improved.

  17. Test report - caustic addition system operability test procedure

    International Nuclear Information System (INIS)

    Parazin, R.E.

    1995-01-01

    This Operability Test Report documents the test results of test procedure WHC-SD-WM-OTP-167 ''Caustic Addition System Operability Test Procedure''. The Objective of the test was to verify the operability of the 241-AN-107 Caustic Addition System. The objective of the test was met

  18. A prototype tap test imaging system: Initial field test results

    Science.gov (United States)

    Peters, J. J.; Barnard, D. J.; Hudelson, N. A.; Simpson, T. S.; Hsu, D. K.

    2000-05-01

    This paper describes a simple, field-worthy tap test imaging system that gives quantitative information about the size, shape, and severity of defects and damages. The system consists of an accelerometer, electronic circuits for conditioning the signal and measuring the impact duration, a laptop PC and data acquisition and processing software. The images are generated manually by tapping on a grid printed on a plastic sheet laid over the part's surface. A mechanized scanner is currently under development. The prototype has produced images for a variety of aircraft composite and metal honeycomb structures containing flaws, damages, and repairs. Images of the local contact stiffness, deduced from the impact duration using a spring model, revealed quantitatively the stiffness reduction due to flaws and damages, as well as the stiffness enhancement due to substructures. The system has been field tested on commercial and military aircraft as well as rotor blades and engine decks on helicopters. Field test results will be shown and the operation of the system will be demonstrated.—This material is based upon work supported by the Federal Aviation Administration under Contract #DTFA03-98-D-00008, Delivery Order No. IA016 and performed at Iowa State University's Center for NDE as part of the Center for Aviation Systems Reliability program.

  19. Current status of technology development on remote monitoring system

    International Nuclear Information System (INIS)

    Yoon, Wan Ki; Lee, Y. K.; Lee, Y. D.; Na, W. W.

    1997-03-01

    IAEA is planning to perform the remote monitoring system in nuclear facility in order to reinforce the economical and efficient inspection. National lab. in U.S. is developing the corresponding core technology and field trial will be done to test the remote monitoring system by considering the case that it replace the current safeguards system. U.S. setup the International Remote Monitoring Project to develop the technology. IAEA makes up remote monitoring team and setup the detail facility to apply remote monitoring system. Therefore, early participation in remote monitoring technology development will make contribution in international remote monitoring system and increase the transparency and confidence in domestic nuclear activities. (author). 12 refs., 20 figs

  20. Alternatives to animal testing: current status and future perspectives.

    Science.gov (United States)

    Liebsch, Manfred; Grune, Barbara; Seiler, Andrea; Butzke, Daniel; Oelgeschläger, Michael; Pirow, Ralph; Adler, Sarah; Riebeling, Christian; Luch, Andreas

    2011-08-01

    On the occasion of the 20th anniversary of the Center for Alternative Methods to Animal Experiments (ZEBET), an international symposium was held at the German Federal Institute for Risk Assessment (BfR) in Berlin. At the same time, this symposium was meant to celebrate the 50th anniversary of the publication of the book "The Principles of Humane Experimental Technique" by Russell and Burch in 1959 in which the 3Rs principle (that is, Replacement, Reduction, and Refinement) has been coined and introduced to foster the development of alternative methods to animal testing. Another topic addressed by the symposium was the new vision on "Toxicology in the twenty-first Century", as proposed by the US-National Research Council, which aims at using human cells and tissues for toxicity testing in vitro rather than live animals. An overview of the achievements and current tasks, as well as a vision of the future to be addressed by ZEBET@BfR in the years to come is outlined in the present paper.

  1. Error response test system and method using test mask variable

    Science.gov (United States)

    Gender, Thomas K. (Inventor)

    2006-01-01

    An error response test system and method with increased functionality and improved performance is provided. The error response test system provides the ability to inject errors into the application under test to test the error response of the application under test in an automated and efficient manner. The error response system injects errors into the application through a test mask variable. The test mask variable is added to the application under test. During normal operation, the test mask variable is set to allow the application under test to operate normally. During testing, the error response test system can change the test mask variable to introduce an error into the application under test. The error response system can then monitor the application under test to determine whether the application has the correct response to the error.

  2. Multiloop integral system test (MIST)

    International Nuclear Information System (INIS)

    Gloudemans, J.R.

    1989-07-01

    The multiloop integral system test (MIST) was part of a multiphase program started in 1983 to address small-break loss-of-coolant accidents (SBLOCAs) specific to Babcock and Wilcox-designed plants. MIST was sponsored by the US Nuclear Regulatory Commission, the Babcock and Wilcox Owners Group, the Electric Power Research Institute, and Babcock and Wilcox. The unique features of the Babcock and Wilcox design, specifically the hot leg U-bends and steam generators, prevented the use of existing integral system data or existing integral system facilities to address the thermal-hydraulic SBLOCA questions. MIST and two other supporting facilities were specifically designed and constructed for this program, and an existing facility -- the once-through integral system (OTIS) -- was also used. Data from MIST and the other facilities will be used to benchmark the adequacy of system codes, such as RELAP5 and TRAC, for predicting abnormal plant transients. The individual tests are described in detail in Volumes 2 through 8 and Volume 11, and are summarized in Volume 1. Inter-group comparisons are addressed in this document, Volume 9. These comparisons are grouped as follows: mapping versus SBLOCA transients, SBLOCA, pump effects, and the effects of noncondensible gases. Appendix A provides an index and description of the microfiched plots for each test, which are enclosed with the corresponding Volumes 2 through 8. 147 figs., 5 tabs

  3. Current Status and Performance Tests of Korea Heat Load Test Facility KoHLT-EB

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Sukkwon; Jin, Hyunggon; Shin, Kyuin; Choi, Boguen; Lee, Eohwak; Yoon, Jaesung; Lee, Dongwon [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Kim, Duckhoi; Cho, Seungyon [National Fusion Research Institute, Daejeon (Korea, Republic of)

    2013-05-15

    A commissioning test has been scheduled to establish the installation and preliminary performance experiments of the copper hypervapotron mockups. And a qualification test will be performed to evaluate the CuCrZr duct liner in the ITER neutral beam injection facility and the ITER first wall small-scale mockups of the semi-prototype, at up to 1.5 and 5 MW/m{sup 2} high heat flux. Also, this system will be used to test other PFCs for ITER and materials for tokamak reactors. Korean high heat flux test facility(KoHLT-EB; Korea Heat Load Test facility - Electron Beam) by using an electron beam system has been constructed in KAERI to perform the qualification test for ITER blanket FW semi-prototype mockups, hypervapotron cooling devices in fusion devices, and other ITER plasma facing components. The commissioning and performance tests with the supplier of e-gun system have been performed on November 2012. The high heat flux test for hypervapotron cooling device and calorimetry were performed to measure the surface heat flux, the temperature profile and cooling performance. Korean high heat flux test facility for the plasma facing components of nuclear fusion machines will be constructed to evaluate the performance of each component. This facility for the plasma facing materials will be equipped with an electron beam system with a 60 kV acceleration gun.

  4. Current limitations and recommendations to improve testing for the environmental assessment of endocrine active substances

    Science.gov (United States)

    Coady, Katherine K.; Biever, Ronald C.; Denslow, Nancy D.; Gross, Melanie; Guiney, Patrick D.; Holbech, Henrik; Karouna-Renier, Natalie K.; Katsiadaki, Ioanna; Krueger, Hank; Levine, Steven L.; Maack, Gerd; Williams, Mike; Wolf, Jeffrey C.; Ankley, Gerald T.

    2017-01-01

    In the present study, existing regulatory frameworks and test systems for assessing potential endocrine active chemicals are described, and associated challenges are discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across geographies, but all basically evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or to the environment. Current test systems include in silico, in vitro, and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect apical data to detect possible adverse effects. These test systems are currently designed to robustly assess endocrine activity and/or adverse effects in the estrogen, androgen, and thyroid hormone signaling pathways; however, there are some limitations of current test systems for evaluating endocrine hazard and risk. These limitations include a lack of certainty regarding: 1) adequately sensitive species and life stages; 2) mechanistic endpoints that are diagnostic for endocrine pathways of concern; and 3) the linkage between mechanistic responses and apical, adverse outcomes. Furthermore, some existing test methods are resource intensive with regard to time, cost, and use of animals. However, based on recent experiences, there are opportunities to improve approaches to and guidance for existing test methods and to reduce uncertainty. For example, in vitro high-throughput screening could be used to prioritize chemicals for testing and provide insights as to the most appropriate assays for characterizing hazard and risk. Other recommendations include adding endpoints for elucidating connections between mechanistic effects and adverse outcomes, identifying potentially sensitive taxa for which test methods currently do not exist, and addressing key endocrine pathways of possible concern in addition to those associated with estrogen, androgen, and thyroid

  5. Orion Ammonia Boiler System Preflight Test Preparations

    Science.gov (United States)

    Levitt, Julia L.

    2017-01-01

    The Environmental Controls and Life Support Systems (ECLSS) branch at Kennedy Space Center (KSC) is currently undergoing preparations for ground testing of the Orion Multi-Purpose Crew Vehicle (MPCV) to prepare its subsystems for EM-1 (Exploration Mission-1). EM-1, Orions second unmanned flight, is a three-week long lunar mission during which the vehicle will complete a 6-day retrograde lunar orbit before returning to Earth. This paper focuses on the work done during the authors 16-week internship with the Mechanical Engineering Branch of KSCs Engineering Directorate. The authors project involved assisting with the preparations for testing the Orion MPCVs ammonia boiler system. The purpose of the ammonia boiler system is to keep the spacecraft sufficiently cool during the reentry portion of its mission, from service module (SM) separation to post-landing. This system is critical for keeping both the spacecraft (avionics and electronics) and crew alive during reentry, thus a successful test of the system is essential to the success of EM-1. XXXX The author was able to draft a detailed outline of the procedure for the ammonia system functional test. More work will need to be done on the vehicle power-up and power-down portions of the procedure, but the ammonia system testing portion of the procedure is thorough and includes vehicle test configurations, vehicle commands, and GSE. The author was able to compile a substantial list of questions regarding the ammonia system functional test with the help of her mentors. A significant number of these questions were answered in the teleconferences with Lockheed Martin.

  6. Test Telemetry And Command System (TTACS)

    Science.gov (United States)

    Fogel, Alvin J.

    1994-01-01

    The Jet Propulsion Laboratory has developed a multimission Test Telemetry and Command System (TTACS) which provides a multimission telemetry and command data system in a spacecraft test environment. TTACS reuses, in the spacecraft test environment, components of the same data system used for flight operations; no new software is developed for the spacecraft test environment. Additionally, the TTACS is transportable to any spacecraft test site, including the launch site. The TTACS is currently operational in the Galileo spacecraft testbed; it is also being provided to support the Cassini and Mars Surveyor Program projects. Minimal personnel data system training is required in the transition from pre-launch spacecraft test to post-launch flight operations since test personnel are already familiar with the data system's operation. Additionally, data system components, e.g. data display, can be reused to support spacecraft software development; and the same data system components will again be reused during the spacecraft integration and system test phases. TTACS usage also results in early availability of spacecraft data to data system development and, as a result, early data system development feedback to spacecraft system developers. The TTACS consists of a multimission spacecraft support equipment interface and components of the multimission telemetry and command software adapted for a specific project. The TTACS interfaces to the spacecraft, e.g., Command Data System (CDS), support equipment. The TTACS telemetry interface to the CDS support equipment performs serial (RS-422)-to-ethernet conversion at rates between 1 bps and 1 mbps, telemetry data blocking and header generation, guaranteed data transmission to the telemetry data system, and graphical downlink routing summary and control. The TTACS command interface to the CDS support equipment is nominally a command file transferred in non-real-time via ethernet. The CDS support equipment is responsible for

  7. Routine testing on protective and safety systems and components

    International Nuclear Information System (INIS)

    Rysy, W.

    1977-01-01

    1) In-process inspection, tests during commissioning. 2) Tests during reactor operation. 2.1) Reactor protection system, for example: continuous auto-testing by a dynamic system, check of the output signals; 2.2) safety features: selected examples: functional tests on the ECCS, trial operation of the emergency diesels. 3) Tests during refuelling phase. 3.1) Containment: Leakage rate tests, leak testing; 3.2) coolant system: selected examples: inservice inspections of the pressure vessel, eddy current testing of the steam generator, functional tests of safety valves. (orig./HP) [de

  8. Inverse problems in eddy current testing using neural network

    Science.gov (United States)

    Yusa, N.; Cheng, W.; Miya, K.

    2000-05-01

    Reconstruction of crack in conductive material is one of the most important issues in the field of eddy current testing. Although many attempts to reconstruct cracks have been made, most of them deal with only artificial cracks machined with electro-discharge. However, in the case of natural cracks like stress corrosion cracking or inter-granular attack, there must be contact region and therefore their conductivity is not necessarily zero. In this study, an attempt to reconstruct natural cracks using neural network is presented. The neural network was trained through numerical simulated data obtained by the fast forward solver that calculated unflawed potential data a priori to save computational time. The solver is based on A-φ method discretized by using FEM-BEM A natural crack was modeled as an area whose conductivity was less than that of a specimen. The distribution of conductivity in that area was reconstructed as well. It took much time to train the network, but the speed of reconstruction was extremely fast after once it was trained. Well-trained network gave good reconstruction result.

  9. Regulation on control systems tests

    International Nuclear Information System (INIS)

    Grau, J.; Navarro, J.M.

    1978-01-01

    Requirements under regulation applicable to the testing of control systems and controlled equipments in the case of USA nuclear projects are examined. They are reviewed, in particular, the following standards and criteria: 10 Code of Federal Regulations 50, Appendix A, General Design Criteria 20 and 21; IEEE Standards 279 and 308; IEEE Standard 338; US Regulatory Guides 1.22 and 1.118.(J.E.de C.)

  10. Current problems regarding abortion, prenatal genetic testing and managing pregnancy

    Directory of Open Access Journals (Sweden)

    Klajn-Tatić Vesna

    2011-01-01

    Full Text Available Current ethical and legal issues with regard to abortion, prenatal genetic testing and managing pregnancy are discussed in this paper. These problems are considered from the legal theory point of view as well as from the standpoint of the Serbian Law, the European Convention for the Protection of Human Rights and Fundamental Freedoms, European Court of Human Rights, legal regulations of several EU countries, the USA, Japan, and their judicial practice. First, the pregnancy termination standards that exist in Serbia are introduced. Then the following issues are explained separately: the pro life and pro choice approaches to abortion; abortion according to the legal approach as a way of survival; the moral and legal status of the fetus; prenatal genetic testing, and finally matters regarding managing pregnancy today. Moral and legal principals of autonomy, namely freedom of choice of the individual, privacy and self-determination give women the right to terminate unwanted pregnancies. In addition, the basic question is whether the right of the woman to abortion clashes with the rights of others. Firstly, with the right of the "fetus to life". Secondly, with the right of the state to intervene in the interest of protecting "the life of the fetus". Third, with the rights of the woman’s partner. The fetus has the moral right to life, but less in relation to the same right of the woman as well as in relation to her right to control her life and her physical and moral integrity. On the other hand, the value of the life of the fetus increases morally and legally with the maturity of gestation; from the third trimester, the interest of the state prevails in the protection of the "life of the fetus" except when the life or health of the pregnant woman are at risk. As regards the rights of the woman’s partner, namely the husband’s opinion, there is no legal significance. The law does not request his participation in the decision on abortion because

  11. Eddy-current tests on operational evaluation of steam generator tubes in nuclear power plants

    International Nuclear Information System (INIS)

    Lopez, Luiz Antonio Negro Martin; Ting, Daniel Kao Sun

    2000-01-01

    This paper presents a worldwide research on the technical and economical impacts due to failure in tube bundles of nuclear power plant steam generators. An Eddy current non destructive test using Foucault currents for the inspection and failure detection on the tubes, and also the main type of defects. The paper also presents the signals generated by a Zetec MIZ-40 test equipment. This paper also presents a brief description of an automatic system for data analysis which is under development by using a fuzzy logic and artificial intelligence

  12. Current system of the solar wind: results of numerical calculation

    International Nuclear Information System (INIS)

    Pisanko, Yu.V.

    1985-01-01

    Results of numerical calculations of surface current in the interplanetary current layer and steady volume current in the solar wind for heliocentric distances (1-10)Rsub(s) (Rsub(s) is the Sun radius) are given. The strength of current dependence on spatial coordinates is considered. Stationary nondissipative magnetohydrodynamic corona expansion (SNMCE) in the reference system rotating with the Sun is studied. Calculations show that three-dimensional current system of nonaxial-symmetric and nonsymmetric relatively to helioequator plane of SNMCE is more complicated than the zonal ring current around the Sun, which is the only component of the current system in spatial symmetric case

  13. Current Trends in the Russian Financial System

    OpenAIRE

    Barisitz, Stephan; Bogetic, Zeljko; Fungacova, Zuzana; Solanko, Laura; Havlik, Peter; Invushin, Valery; Osakovsky, Vladimir V.; Revoltella, Debora; Lehmann, Alexander; Nowotny, Ewald; Pineau-Valencienne, Cyril; Sutela, Pekka

    2009-01-01

    The papers in the present SUERF Study is a selection of the papers presented at a SUERF Workshop and Special OeNB East Jour Fixe held at Oesterreichische Nationalbank in Vienna on 23 January 2009. In his opening remarks (chapter 2), Ewald Nowotny, Governor of the Oesterreichische Nationalbank referred to Austrian banks? engagement with neighbouring Central and Eastern European Countries. The current crisis should not make people forget the fact that Austrian banks? deep engagement with the ne...

  14. Tokamak plasma current disruption infrared control system

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ulrickson, M.

    1987-01-01

    This patent describes a device for magnetically confining a plasma driven by a plasma current and contained within a toroidal vacuum chamber, the device having an inner toroidal limiter on an inside wall of the vacuum chamber and an arrangement for the rapid prediction and control in real time of a major plasma disruption. The arrangement is described which includes: scanning means sensitive to infrared radiation emanating from within the vacuum chamber, the infrared radiation indicating the temperature along a vertical profile of the inner toroidal limiter. The scanning means is arranged to observe the infrared radiation and to produce in response thereto an electrical scanning output signal representative of a time scan of temperature along the vertical profile; detection means for analyzing the scanning output signal to detect a first peaked temperature excursion occurring along the profile of the inner toroidal limiter, and to produce a detection output signal in repsonse thereto, the detection output signal indicating a real time prediction of a subsequent major plasma disruption; and plasma current reduction means for reducing the plasma current driving the plasma, in response to the detection output signal and in anticipation of a subsequent major plasma disruption

  15. Systemic radiotherapy: current status and prospects

    International Nuclear Information System (INIS)

    Bogatyreva, T.I.

    1989-01-01

    Evolution of methods for whole-body irradiation and the range of its application is described. Data on clinical efficiency and endurance of main types of systemic radiotherapy are generalized. It is shown that systemic irradiation as successive half-body irradiation (HBI) is the effective method for palliative care of patients with cancer in advanced forms. Early radiation complications are studied and tolerance doses of single irradiation of critical organs are established. Combinaton of systemic irradiation with chemotherapy is perspective. It is shown the the main tendency is trausition of total irradiation and single successive HBI to fractionated irradiation, when the effect on tumor is strengthened to increase a integral dose

  16. The application of neural network for the advancement of the eddy current testing

    International Nuclear Information System (INIS)

    Sakai, T.; Soneda, N.

    1996-01-01

    All the steam generator (SG) tubes of Japanese pressurized water reactors (PWRs) are inspected by the eddy current testing (ECT) method in every annual scheduled inspection. Here, a neural network system to estimate the class and size of defects from signals obtained by the eddy current testing (ECT) method has been developed. A trajectory of ECT signal is characterized by four representative parameters, and totally eight parameters obtained from two trajectories by different AC current frequencies are used as input parameters for neutral networks. A probabilistic descent method is employed to minimize the error at the learning process of neural networks. It is indicated that using multiple neutral networks which are separately responsible to each class of defects is effective to the improvement of their estimation accuracy. And, it is demonstrated that the neural network system which the authors developed can estimate the class and size of defects from unlearned trajectories with high accuracy

  17. Current position on software for the automatic data acquisition system

    International Nuclear Information System (INIS)

    1988-01-01

    This report describes the current concepts for software to control the operation of the Automatic Data Acquisition System (ADAS) proposed for the Deaf Smith County, Texas, Exploratory Shaft Facility (ESF). The purpose of this report is to provide conceptual details of how the ADAS software will execute the data acquisition function, and how the software will make collected information available to the test personnel, the Data Management Group (DMG), and other authorized users. It is not intended that this report describe all of the ADAS functions in exact detail, but the concepts included herein will form the basis for the formal ADAS functional requirements definition document. 5 refs., 14 figs

  18. Eddy current testing for blade edge micro cracks of aircraft engine

    Science.gov (United States)

    Zhang, Wei-min; Xu, Min-dong; Gao, Xuan-yi; Jin, Xin; Qin, Feng

    2017-10-01

    Based on the problems of low detection efficiency in the micro cracks detection of aircraft engine blades, a differential excitation eddy current testing system was designed and developed. The function and the working principle of the system were described, the problems which contained the manufacture method of simulated cracks, signal generating, signal processing and the signal display method were described. The detection test was carried out by taking a certain model aircraft engine blade with simulated cracks as a tested specimen. The test data was processed by digital low-pass filter in the computer and the crack signals of time domain display and Lissajous figure display were acquired. By comparing the test results, it is verified that Lissajous figure display shows better performance compared to time domain display when the crack angle is small. The test results show that the eddy current testing system designed in this paper is feasible to detect the micro cracks on the aeroengine blade and can effectively improve the detection efficiency of micro cracks in the practical detection work.

  19. Current dental adhesives systems. A narrative review.

    Science.gov (United States)

    Milia, Egle; Cumbo, Enzo; Cardoso, Rielson Jose A; Gallina, Giuseppe

    2012-01-01

    Adhesive dentistry is based on the development of materials which establish an effective bond with the tooth tissues. In this context, adhesive systems have attracted considerable research interest in recent years. Successful adhesive bonding depends on the chemistry of the adhesive, on appropriate clinical handling of the material as well as on the knowledge of the morphological changes caused on dental tissue by different bonding procedures. This paper outlines the status of contemporary adhesive systems, with particular emphasis on chemical characteristics and mode of interaction of the adhesives with enamel and dentinal tissues. Dental adhesives are used for several clinical applications and they can be classified based on the clinical regimen in "etch-and-rinse adhesives" and "self-etch adhesives". Other important considerations concern the different anatomical characteristics of enamel and dentine which are involved in the bonding procedures that have also implications for the technique used as well as for the quality of the bond. Etch-and-rinse adhesive systems generally perform better on enamel than self-etching systems which may be more suitable for bonding to dentine. In order to avoid a possible loss of the restoration, secondary caries or pulp damage due to bacteria penetration or due to cytotoxicity effects of eluted adhesive components, careful consideration of several factors is essential in selecting the suitable bonding procedure and adhesive system for the individual patient situation.

  20. Current Limitations and Recommendations to Improve Testing for the Environmental Assessment of Endocrine Active Substances

    DEFF Research Database (Denmark)

    Coady, Katherine K; Biever, Ronald C; Denslow, Nancy D

    2017-01-01

    In this paper existing regulatory frameworks and test systems for assessing potential endocrine-active chemicals are described, and associated challenges discussed, along with proposed approaches to address these challenges. Regulatory frameworks vary somewhat across geographies, but all basically...... evaluate whether a chemical possesses endocrine activity and whether this activity can result in adverse outcomes either to humans or the environment. Current test systems include in silico, in vitro and in vivo techniques focused on detecting potential endocrine activity, and in vivo tests that collect...... methods currently do not exist, and addressing key endocrine pathways of possible concern in addition to those associated with estrogen, androgen and thyroid signaling. This article is protected by copyright. All rights reserved....

  1. Current trends on knowledge-based systems

    CERN Document Server

    Valencia-García, Rafael

    2017-01-01

    This book presents innovative and high-quality research on the implementation of conceptual frameworks, strategies, techniques, methodologies, informatics platforms and models for developing advanced knowledge-based systems and their application in different fields, including Agriculture, Education, Automotive, Electrical Industry, Business Services, Food Manufacturing, Energy Services, Medicine and others. Knowledge-based technologies employ artificial intelligence methods to heuristically address problems that cannot be solved by means of formal techniques. These technologies draw on standard and novel approaches from various disciplines within Computer Science, including Knowledge Engineering, Natural Language Processing, Decision Support Systems, Artificial Intelligence, Databases, Software Engineering, etc. As a combination of different fields of Artificial Intelligence, the area of Knowledge-Based Systems applies knowledge representation, case-based reasoning, neural networks, Semantic Web and TICs used...

  2. Electromagnetic Environmental Effects System Testing

    Science.gov (United States)

    2013-11-20

    localized ( spot ) illumination is adequate to evaluate potential responses by illuminating specific apertures, cables and subsystems. At these...the EMC testing. The Battlefield Functional Area Control System (BFACS), Force XXI Blue Force Tracker (BFT), routers, hubs, switches, etc, are... Laser Printer F1 F1 F1 G G G G G G G G G G G G G G G G G G G G G G G G G G Embedded Training Module F1 F1 F1 G G G G G G G G G G G G G G G G G G G G G

  3. Current use of pharmacogenetic testing: a national survey of thiopurine methyltransferase testing prior to azathioprine prescription.

    Science.gov (United States)

    Fargher, E A; Tricker, K; Newman, W; Elliott, R; Roberts, S A; Shaffer, J L; Bruce, I; Payne, K

    2007-04-01

    Azathioprine is an immunosuppressant prescribed for the treatment of inflammatory conditions and after organ transplantation. Risk of neutropaenia has limited the effective use of azathioprine (AZA) and driven requirements for careful monitoring and blood tests. Thiopurine methyltransferase (TPMT) is a genetically moderated key enzyme involved in the metabolism of AZA that can be used to stratify individuals into different levels of risk of developing neutropaenia. Two techniques can be used to measure TPMT status: enzyme-level testing (phenotype testing) and DNA based testing (genotype testing). To identify the current uptake of TPMT enzyme-level testing, TPMT genotype testing, and, the role of guidelines; to inform the prescribing and monitoring of AZA. A survey was mailed to a consultant dermatologist, gastroenterologist, and rheumatologist at every NHS Hospital Trust in England. The survey comprised mainly closed questions exploring: use of AZA and monitoring; use of TPMT enzyme-level testing and genotype testing; and, the role of guidelines to guide prescribing practice. A 70% (n=287) response rate was obtained. The majority of respondents reported prescribing AZA (99%, n=283). Prescribing and monitoring patterns differed between individual respondents and between the three disciplines. TPMT enzyme-level testing was reportedly used by 67% (n=189) of respondents, but this differed by discipline (dermatologists 94%, gastroenterologists 60%, rheumatologists 47%). In 91% of cases enzyme-level testing was carried out prior to prescribing AZA. Genotype testing is not typically available to NHS clinicians but 15 clinicians (six dermatologists, six gastroenterologists, three rheumatologists) reported using it. Most consultants (82%) reported using guidelines to inform their AZA prescribing and monitoring (dermatologists 81%, gastroenterologists 75%, rheumatologists 94%). Two-thirds of the consultants surveyed in England are using TPMT enzyme-level testing, prior to

  4. Current status of the TSensor systems roadmap

    NARCIS (Netherlands)

    Walsh, Steven Thomas; Bryzek, Janusz; Pisano, Albert P.

    2014-01-01

    We apply our work from the contemporary pharmaceutical industry to generate a third generation-style technology roadmap for TSensor Systems. First we identify drivers and consortia. We then identify relevant technology components, namely multiple root technologies, multiple unit cells, multiple

  5. Power Testing in Basketball: Current Practice and Future Recommendations.

    Science.gov (United States)

    Wen, Neal; Dalbo, Vincent J; Burgos, Bill; Pyne, David B; Scanlan, Aaron T

    2018-02-01

    Numerous foundational movements performed during basketball are predicated on underlying power-related attributes, including speed, change-of-direction, and jumping. Accordingly, fitness testing batteries for basketball have incorporated an assortment of linear speed tests, change-of-direction tests, and jump tests. However, due to the wide variety of testing options it is difficult for basketball practitioners to select appropriate testing protocols for the assessment of power-related attributes. As a result, there is a need to review the relevant literature to identify game-specific, power-related attributes important in basketball and the most appropriate tests available to assess power-related attributes for basketball practitioners. Therefore, the aims of this review were to: (1) identify essential power-related attributes important in basketball; (2) discuss the suitability of common and novel power-related tests; and (3) provide recommendations for future research and best practice approaches for basketball coaching staff. In this review, we propose a series of novel tests that are more targeted and specific to basketball movements including: (1) 5-m and 10-m linear sprints, (2) Modified Agility T-Test, (3) Change-of-Direction Deficit, (4) lateral bound, (5) Sargent jump, (6) one-step jump, and (7) isometric midthigh pull test. Improved testing of power-related attributes should enable basketball practitioners to develop targeted training plans for enhancing player performance.

  6. Current Mode Data Converters for Sensor Systems

    DEFF Research Database (Denmark)

    Jørgensen, Ivan Herald Holger

    .8 micron BiCMOS process. The performance of the first DAC presented is a SFDR of 43dB for a generated frequency of approximately 30MHz and at a sampling rate of 100MSamples/s. The SFDR is 50dB for a generated frequency of approximately 10MHz. The maximum conversion rate is 140MSamples/s. The second DAC......This thesis is mainly concerned with data conversion. Especially data conversion using current mode signal processing is treated.A tutorial chapter introducing D/A conversion is presented. In this chapter the effects that cause static and dynamic nonlinearities are discussed along with methods...... of noise in SI is presented which leads to a new optimization methodology for SI. The optimization methodology minimizes the power consumption for a given performance (SNR and THD). The optimization methodology also takes process variations into account.Six chips have been implemented based on the theory...

  7. Eddy-Current Testing of Welded Stainless Steel Storage Containers to Verify Integrity and Identity

    International Nuclear Information System (INIS)

    Tolk, Keith M.; Stoker, Gerald C.

    1999-01-01

    An eddy-current scanning system is being developed to allow the International Atomic Energy Agency (IAEA) to verify the integrity of nuclear material storage containers. Such a system is necessary to detect attempts to remove material from the containers in facilities where continuous surveillance of the containers is not practical. Initial tests have shown that the eddy-current system is also capable of verifying the identity of each container using the electromagnetic signature of its welds. The DOE-3013 containers proposed for use in some US facilities are made of an austenitic stainless steel alloy, which is nonmagnetic in its normal condition. When the material is cold worked by forming or by local stresses experienced in welding, it loses its austenitic grain structure and its magnetic permeability increases. This change in magnetic permeability can be measured using an eddy-current probe specifically designed for this purpose. Initial tests have shown that variations of magnetic permeability and material conductivity in and around welds can be detected, and form a pattern unique to the container. The changes in conductivity that are present around a mechanically inserted plug can also be detected. Further development of the system is currently underway to adapt the system to verifying the integrity and identity of sealable, tamper-indicating enclosures designed to prevent unauthorized access to measurement equipment used to verify international agreements

  8. Intraoral scanning systems - a current overview.

    Science.gov (United States)

    Zimmermann, M; Mehl, A; Mörmann, W H; Reich, S

    2015-01-01

    There is no doubt today about the possibilities and potential of digital impression-taking with the aid of intraoral optical impression systems, and the past few years have seen a considerable increase in the range of optical intraoral scanners available on the market. On the strength of numerous innovations and a wider range of indications in orthodontics and implantology, intraoral scanning systems appear to be a highly promising development for the future. Digital impression-taking with intraoral scanners has already shown itself in some respects to be clearly superior to conventional impression- taking. Particularly worthy of mention is the versatile integration of digital impressions into diagnostic and treatment concepts to provide a customizable healthcare solution for the patient. It remains exciting to look forward to future developments that will allow us to observe digital impression-taking--as with other digital applications already established in everyday life--becoming firmly established in the routine of dentistry and dental technology. This article presents an overview of the benefits and limitations of digital impression-taking using intraoral scanning systems, and includes a summary of all the relevant intraoral scanners available on the market at present.

  9. NADIR: A Flexible Archiving System Current Development

    Science.gov (United States)

    Knapic, C.; De Marco, M.; Smareglia, R.; Molinaro, M.

    2014-05-01

    The New Archiving Distributed InfrastructuRe (NADIR) is under development at the Italian center for Astronomical Archives (IA2) to increase the performances of the current archival software tools at the data center. Traditional softwares usually offer simple and robust solutions to perform data archive and distribution but are awkward to adapt and reuse in projects that have different purposes. Data evolution in terms of data model, format, publication policy, version, and meta-data content are the main threats to re-usage. NADIR, using stable and mature framework features, answers those very challenging issues. Its main characteristics are a configuration database, a multi threading and multi language environment (C++, Java, Python), special features to guarantee high scalability, modularity, robustness, error tracking, and tools to monitor with confidence the status of each project at each archiving site. In this contribution, the development of the core components is presented, commenting also on some performance and innovative features (multi-cast and publisher-subscriber paradigms). NADIR is planned to be developed as simply as possible with default configurations for every project, first of all for LBT and other IA2 projects.

  10. Eddy current testing probe with dual half-cylindrical coils

    Science.gov (United States)

    Bae, Byung-Hoon; Choi, Jung-Mi; Kim, Soo-Yong

    2000-02-01

    We have developed a new eddy current probe composed of a dual half-cylindrical (2HC) coil as an exciting coil and a sensing coil that is placed in the small gap of the 2HC coil. The 2HC coil induces a linear eddy current on the narrow region within the target medium. The magnitude of eddy current has a maximum peak with the narrow width, underneath the center of the exciting 2HC coil. Because of the linear eddy current, the probe can be used to detect not only the existence of a crack but also its direction in conducting materials. Using specimen with a machined crack, and varying the exciting frequency from 0.5 to 100 kHz, we investigated the relationships between the direction of crack and the output voltage of the sensing coil.

  11. Test of right-handed currents in baryon semileptonic decays

    International Nuclear Information System (INIS)

    Garcia, A.; Huerta, R.; Maya, M.; Perez Marcial, R.

    1985-01-01

    The effect of a right-handed boson on baryon semileptonic decay is considered. The analysis of polarized and unpolarized decays is carried out and it is shown that the best place to look for a right-handed current (RHC) signature is in polarized baryon decay. However, our results are useful for high statistics experiments. In order to see the contribution of the right-handed currents in the case of unpolarized hyperon decay, the Cabibbo theory should be assumed. (orig.)

  12. Current trends in microsponge drug delivery system.

    Science.gov (United States)

    Gangadharappa, H V; Gupta, N Vishal; Prasad M, Sarat Chandra; Shivakumar, H G

    2013-08-01

    Microsponge is a microscopic sphere capable of absorbing skin secretions, therefore reducing the oiliness of the skin. Microsponge having particle size of 10-25 microns in diameter, have wide range of entrapment of various ingredients in a single microsponges system and release them at desired rates. Conventional topical preparations have various disadvantages due to irritancy, odour, greasiness and patient compliance. In many topical dosage forms fail to reach the systemic circulation in sufficient amounts in few cases. These problems overcome by the usage of formulation as microsponge in the areas of research. Drug release in microsponge is done by the external stimuli like pH, temperature and rubbing. It has several advantageous over the other topical preparations in being non-allergenic, non-toxic, non-irritant and non- mutagenic. These microsponges are used in the sun screens, creams, ointments, over-the-counter skin care preparations, recently nanosponge were reported in literature used in delivery of drug by the use of cyclodextrins to enhance the solubility of poorly water soluble drugs, which are meant for topical application.

  13. Automation of eddy current system for in-service inspection of turbine and generator rotor bores

    International Nuclear Information System (INIS)

    Anon.

    1987-01-01

    The current project (EPRI-RP-1975-5) is a continuation of activities that began several years ago. Those results (EPRI-RP-1957-1) indicated that eddy current testing shows promise for in-service inspection. The current project investigates the degree to which eddy current testing can be used to replace bore magnetic particle testing. For this purpose, correlation studies between eddy current and magnetic particle tests are being undertaken on laboratory rotor sections and field test pieces of rotors. The eddy current data are to be gathered automatically by a combination of the Nortec-25L Eddyscope (to provide the analog eddy current signals) and the General Electric DATAQ/sup TM/ (a registered trademark of the General Electric Co.) System (to perform the automatic data acquisition). This paper describes some test results on a flaked laboratory rotor section

  14. Role of Urine Drug Testing in the Current Opioid Epidemic.

    Science.gov (United States)

    Mahajan, Gagan

    2017-12-01

    While the evidence for urine drug testing for patients on chronic opioid therapy is weak, the guidelines created by numerous medical societies and state and federal regulatory agencies recommend that it be included as one of the tools used to monitor patients for compliance with chronic opioid therapy. To get the most comprehensive results, clinicians should order both an immunoassay screen and confirmatory urine drug test. The immunoassay screen, which can be performed as an in-office point-of-care test or as a laboratory-based test, is a cheap and convenient study to order. Limitations of an immunoassay screen, however, include having a high threshold of detectability and only providing qualitative information about a select number of drug classes. Because of these restrictions, clinicians should understand that immunoassay screens have high false-positive and false-negative rates. Despite these limitations, though, the results can assist the clinician with making preliminary treatment decisions. In comparison, a confirmatory urine drug test, which can only be performed as a laboratory-based test, has a lower threshold of detectability and provides both qualitative and quantitative information. A urine drug test's greater degree of specificity allows for a relatively low false-negative and false-positive rate in contrast to an immunoassay screen. Like any other diagnostic test, an immunoassay screen and a confirmatory urine drug test both possess limitations. Clinicians must keep this in mind when interpreting an unexpected test result and consult with their laboratory when in doubt about the meaning of the test result to avoid making erroneous decisions that negatively impact both the patient and clinician.

  15. Current status of nephrogenic systemic fibrosis

    International Nuclear Information System (INIS)

    Daftari Besheli, L.; Aran, S.; Shaqdan, K.; Kay, J.; Abujudeh, H.

    2014-01-01

    Nephrogenic systemic fibrosis (NSF) occurs in patients with advanced chronic kidney disease (CKD) or acute renal failure, most commonly following exposure to gadolinium-based contrast agents (GBCAs). NSF can be debilitating and associated with increased mortality. The putative association of NSF with GBCAs prompted the development of guidelines to limit the use of these contrast agents in at-risk patients. Indeed, the incidence of NSF has decreased dramatically following application of these guidelines, which appears to be the only effective means of decreasing NSF incidence. Thus, increasing clinician awareness of these updated guidelines is important. The present review introduces and compares updated guidelines for GBCA use and discusses the latest advances in the understanding of the pathogenic mechanisms and treatment of NSF

  16. Evaluation of Defects of Thermal Barrier Coatings by Thermal Shock Test Using Eddy Current Testing

    Energy Technology Data Exchange (ETDEWEB)

    Heo, Tae Hoon; Cho, Youn Ho; Lee, Joon Hyun [Pusan National University, Busan (Korea, Republic of); Oh, Jeong Seok; Lee, Koo Hyun [KIMM, Daejeon (Korea, Republic of)

    2009-10-15

    Periodical thermal shock can introduce defects in thermal barrier coating made by layers of CoNiCrAlY bond coating(BC) and ZrO{sub 2}-8wt%Y{sub 2}O{sub 3} ceramic top coating(TC) on Inconel-738 substrate using plasma spraying. Thermal shock test is performed by severe condition that is to heat until 1000 .deg. C and cool until 20 .deg. C. As the number of cycle is increased, the fatigue by thermal shock is also increased. After test, the micro-structures and mechanical characteristics of thermal barrier coating were investigated by SEM, XRD. The TGO layer of is Al{sub 2}O{sub 3} formed between BC and TC by periodical thermal shock test, and its change in thickness is inspected by eddy current test(ECT). By ECT test, it is shown that TGO and micro-crack can be detected and it is possible to predict the life of thermal barrier coating

  17. Tunneling Current Probe for Noncontract Wafer-Level Photodiode Array Testing

    National Research Council Canada - National Science Library

    Verdun, Horacio

    1999-01-01

    The Tunneling Current Probe (TCP) is an automated picometer-sensitive proximity sensor and current measurement system which measures the current through a photodiode detector array element by establishing a tunneling current...

  18. Launch Control System Software Development System Automation Testing

    Science.gov (United States)

    Hwang, Andrew

    2017-01-01

    The Spaceport Command and Control System (SCCS) is the National Aeronautics and Space Administration's (NASA) launch control system for the Orion capsule and Space Launch System, the next generation manned rocket currently in development. This system requires high quality testing that will measure and test the capabilities of the system. For the past two years, the Exploration and Operations Division at Kennedy Space Center (KSC) has assigned a group including interns and full-time engineers to develop automated tests to save the project time and money. The team worked on automating the testing process for the SCCS GUI that would use streamed simulated data from the testing servers to produce data, plots, statuses, etc. to the GUI. The software used to develop automated tests included an automated testing framework and an automation library. The automated testing framework has a tabular-style syntax, which means the functionality of a line of code must have the appropriate number of tabs for the line to function as intended. The header section contains either paths to custom resources or the names of libraries being used. The automation library contains functionality to automate anything that appears on a desired screen with the use of image recognition software to detect and control GUI components. The data section contains any data values strictly created for the current testing file. The body section holds the tests that are being run. The function section can include any number of functions that may be used by the current testing file or any other file that resources it. The resources and body section are required for all test files; the data and function sections can be left empty if the data values and functions being used are from a resourced library or another file. To help equip the automation team with better tools, the Project Lead of the Automated Testing Team, Jason Kapusta, assigned the task to install and train an optical character recognition (OCR

  19. Comprehensive Nuclear-Test-Ban Treaty: Background and Current Developments

    Science.gov (United States)

    2013-06-10

    response, Japan, the United Kingdom, and the United States warned of consequences if North Korea conducted a test; South Korea expressed “deep regret and... Unicorn ,” was conducted in a “down-hole” or vertical shaft configuration similar to an underground nuclear test...26; 2003: Piano, September 19; 2004: Armando, May 25; 2006: Krakatau (jointly with UK), February 23; Unicorn , August 30; 2010: Bacchus, September 15

  20. Industrial-Strength Model-Based Testing - State of the Art and Current Challenges

    Directory of Open Access Journals (Sweden)

    Jan Peleska

    2013-03-01

    Full Text Available As of today, model-based testing (MBT is considered as leading-edge technology in industry. We sketch the different MBT variants that - according to our experience - are currently applied in practice, with special emphasis on the avionic, railway and automotive domains. The key factors for successful industrial-scale application of MBT are described, both from a scientific and a managerial point of view. With respect to the former view, we describe the techniques for automated test case, test data and test procedure generation for concurrent reactive real-time systems which are considered as the most important enablers for MBT in practice. With respect to the latter view, our experience with introducing MBT approaches in testing teams are sketched. Finally, the most challenging open scientific problems whose solutions are bound to improve the acceptance and effectiveness of MBT in industry are discussed.

  1. High power tests of beryllium oxide windows to the lower hybrid current drive launcher in JET

    International Nuclear Information System (INIS)

    Ekedahl, A.; Brandon, M.; Finburg, P.

    1999-01-01

    The vacuum windows to the 3.70 GHz Lower Hybrid Current Drive (LHCD) system in JET were originally designed to withstand 350 kW for 20 s with VSWR ≤ 1.8. High power RF tests of the windows have been carried out in the LHCD test facility at JET. All windows that were tested could operate at 500 kW for 10 s in a matched load. Two windows passed an endurance test at 250 kW for 20 s with the windows terminated in a short circuit. One window also passed this endurance test without active cooling. The results show that this type of window can be used in a new advanced launcher, as proposed for ITER, in which the output power from each klystron (P ≤ 500 kW) will be transmitted through one waveguide and one vacuum window. (author)

  2. Performance testing SPECT systems: Recent developments

    International Nuclear Information System (INIS)

    Todd-Pokropek, A.

    1985-01-01

    A protocol is used to test as many currently available systems as possible, including both rotating gamma camera systems from GE, Siemens, Toshiba, Technicare, Elscint, Philips, Picker, etc, and single/multi slice system such as the Medimatic. This paper indicates changes that have occurred with respect to preliminary results previously published. Reconstructions were performed in a standard manner, using a Ramp filter and without attenuation correction, in order to reduce the effect of differences in software. The Jaszczak phantom was used to assess overall image quality. Tests were performed using the different collimators available. Image quality improved with better spatial resolution, even at the expense of sensitivity. Non-circular orbits, where available, were tested, and resolution was comparing for various positions and directions. With double headed systems, the results obtained were compared to those using a single head alone. Some gain in image quality seems to have been achieved by better uniformity resulting from improved correction circuitry, by the use of non-circular orbits, and from scatter correction. Potential still exists to improve collimator design

  3. Differential current measurement in the BNL energy recovery linac test facility

    International Nuclear Information System (INIS)

    Cameron, Peter

    2006-01-01

    An energy recovery linac (ERL) test facility is presently under construction at BNL [V.N. Litvinenko, et al., High current energy recovery linac at BNL, PAC, 2005; I. Ben-Zvi, et al., Extremely high current, high brightness energy recovery linac, PAC, 2005]. The goal of this test facility is to demonstrate CW operation with an average beam current greater than 100mA, and with greater than 99.95% efficiency of current recovery. This facility will serve as a test bed for the novel high current CW photo-cathode [A. Burrill, et al., Multi-alkali photocathode development at BNL, PAC, 2005; A. Murray, et al., State-of-the-art electron guns and injector designs for energy recovery linacs, PAC, 2005], the superconducting RF cavity with HOM dampers [R. Calaga, et al., High current superconducting cavities at RHIC, EPAC, 2004; R. Calaga, et al., in: Proceedings of the 11th workshop on RF superconductivity, Lubeck, Germany, 2003], and the lattice [D. Kayran, V. Litvinenko, Novel method of emittance preservation in ERL merging system in presence of strong space charge forces, PAC, 2005; D. Kayran, et al., Optics for high brightness and high current ERL project at BNL, PAC, 2005] and feedback systems needed to insure the specified beam parameters. It is an important stepping stone for electron cooling in RHIC [I. Ben-Zvi, et al., Electron cooling of RHIC, PAC, 2005], and essential to meet the luminosity specifications of RHICII [T. Hallman, et al., RHICII/eRHIC white paper, available at http://www.bnl.gov/henp/docs/NSAC_RHICII-eRHIC_2-15-03.pdf]. The expertise and experience gained in this effort might also extend forward into a 10-20GeV ERL for the electron-ion collider eRHIC [http://www.agsrhichome.bnl.gov/eRHIC/, Appendix A, The linac-ring option, 2005]. We report here on the use of a technique of differential current measurement to monitor the efficiency of current recovery in the test facility, and investigate the possibility of using such a monitor in the machine

  4. Numeric signal analysis process, with particular application to eddy current testing

    International Nuclear Information System (INIS)

    Combes, J.Y.; Ledinghen, E. de; Lionti, F.

    1996-01-01

    Eddy current testing uses analogic demodulation process, and then analog or digital phase shift measurement. These techniques are efficient, but not always versatile enough to apply to different configurations, in particular when a change of operating frequency is requested. This method performs an entirely digital conditioning. Excitation is simultaneously performed at N different frequencies (typically N=4). By sampling at a much higher frequency, 2N equation are obtained, allowing the resolution of the linear equations system. (D.L.)

  5. Internet of Things: Current Challenges in the Quality Assurance and Testing Methods

    OpenAIRE

    Bures, Miroslav; Cerny, Tomas; Ahmed, Bestoun S.

    2018-01-01

    Contemporary development of the Internet of Things (IoT) technology brings a number of challenges in the Quality Assurance area. Current issues related to security, user's privacy, the reliability of the service, interoperability, and integration are discussed. All these create a demand for specific Quality Assurance methodology for the IoT solutions. In the paper, we present the state of the art of this domain and we discuss particular areas of system testing discipline, which is not covered...

  6. Investigating discrimination model of the signals obtained by eddy current testing

    International Nuclear Information System (INIS)

    Wache, G.; Rivenez, J.

    1986-01-01

    A software using an eddy current system controlled by a desk computer has been developed in order to separate a characteristic physical value among several parts. The numerical process involved uses multiparameter measurements done previously on significant parts belonging to the same class. The analysis presented deals with hardness testing of steel bolts in relation with heat-treatment, but other applications dealing with either micro structure check or defect investigation, could be done in the future by using a similar method

  7. Test results of HTTR control system

    International Nuclear Information System (INIS)

    Motegi, Toshihiro; Iigaki, Kazuhiko; Saito, Kenji; Sawahata, Hiroaki; Hirato, Yoji; Kondo, Makoto; Shibutani, Hideki; Ogawa, Satoru; Shinozaki, Masayuki; Mizushima, Toshihiko; Kawasaki, Kozo

    2006-06-01

    The plant control performance of the IHX helium flow rate control system, the PPWC helium flow rate control system, the secondary helium flow rate control system, the inlet temperature control system, the reactor power control system and the outlet temperature control system of the HTTR are obtained through function tests and power-up tests. As the test results, the control systems show stable control response under transient condition. Both of inlet temperature control system and reactor power control system shows stable operation from 30% to 100%, respectively. This report describes the outline of control systems and test results. (author)

  8. System Testing of Desktop and Web Applications

    Science.gov (United States)

    Slack, James M.

    2011-01-01

    We want our students to experience system testing of both desktop and web applications, but the cost of professional system-testing tools is far too high. We evaluate several free tools and find that AutoIt makes an ideal educational system-testing tool. We show several examples of desktop and web testing with AutoIt, starting with simple…

  9. Testing of a Microanalysis System

    NARCIS (Netherlands)

    Kerkhoff, Hans G.

    2001-01-01

    During the testing of microsystems, one has to cope with many problems resulting from inaccessibility, different technologies, and nonelectrical failure modes. A number of mixed-signal test techniques have been applied to test a new advanced microsystem. The choices on testing are directly dependent

  10. Current status and burning issues in immunotoxicity testing of drugs

    International Nuclear Information System (INIS)

    Laan, Jan Willem van der; Loveren, Henk van

    2005-01-01

    Besides pathology endpoints, additional immune function endpoints have been included in the Note for Guidance on Repeated Dose Toxicity by the European Union (July 2001), which concern the analysis of antibody responses to a T-cell-dependent antigen. Guidance papers of other regulatory authorities are published as well. The main issue is the need for functional immunotoxicity testing to detect unintended immunosuppression. The International Conference on Harmonization (ICH) has surveyed studies from the files of the pharmaceutical industry to find the proportion of compounds that can be detected by additional immunotoxicity testing. Preliminary analysis shows that 10-15% of the compounds in the survey only react positively to the additional tests. More data are requested from the pharmaceutical industry. The Expert Working Group of the ICH has decided to choose a cause-for-concern approach to immmunotoxicity rather than a routine-screening approach. The causes for concern are to be defined during ICH negotiations

  11. Testing of nuclear air-cleaning systems

    International Nuclear Information System (INIS)

    Anon.

    1975-01-01

    A standard is presented which describes methods for field-testing nuclear power plant air cleaning systems. Included are specifications for visual inspection; duct and housing leak test; mounting frame pressure leak test; airflow capacity, distribution, and residence time tests; air-aerosol mixing uniformity test; in place leak test of HEPA filter banks; multiple sampling technique; in-place leak test of adsorber stage; laboratory testing of adsorbent; and duct heater performance test

  12. Fatigue tests of dowel-socket systems

    International Nuclear Information System (INIS)

    Chiang, D.D.

    1976-01-01

    A test program was conducted to determine the fatigue behavior of LHTGR fuel element dowel/socket systems. Two dowel/socket systems, namely, a four-dowel system and a five-dowel system, were tested to failure under shear loads applied through a fatigue test apparatus to simulate repetitive loading during a seismic event

  13. Test cases for interface tracking methods: methodology and current status

    International Nuclear Information System (INIS)

    Lebaigue, O.; Jamet, D.; Lemonnier, E.

    2004-01-01

    Full text of publication follows:In the past decade, a large number of new methods have been developed to deal with interfaces in the numerical simulation of two-phase flows. We have collected a set of 36 test cases, which can be seen as a tool to help engineers and researchers selecting the most appropriate method(s) for their specific fields of application. This set can be use: - To perform an initial evaluation of the capabilities of available methods with regard to the specificity of the final application and the most important features to be recovered from the simulation. - To measure the maximum mesh size to be used for a given physical problem in order to obtain an accurate enough solution. - To assess and quantify the performances of a selected method equipped with its set of physical models. The computation of a well-documented test case allows estimating the error due to the numerical technique by comparison with reference solutions. This process is compulsory to gain confidence and credibility on the prediction capabilities of a numerical method and its physical models. - To broaden the capabilities of a given numerical technique. The test cases may be used to identify the need for improvement of the overall numerical scheme or to determine the physical part of the model, which is responsible for the observed limitations. Each test case falls within one of the following categories: - Analytical solutions of well-known sets of equations corresponding to simple geometrical situations. - Reference numerical solutions of moderately complex problems, produced by accurate methods (e.g., boundary Fitted coordinate method) on refined meshes. - Separate effects analytical experiments. The presentation will suggest how to use the test cases for assessing the physical models and the numerical methods. The expected fallout of using test cases is indeed on the one hand to identify the merits of existing methods and on the other hand to orient further research towards

  14. Microcomputer based test system for charge coupled devices

    International Nuclear Information System (INIS)

    Sidman, S.

    1981-02-01

    A microcomputer based system for testing analog charge coupled integrated circuits has been developed. It measures device performance for three parameters: dynamic range, baseline shift due to leakage current, and transfer efficiency. A companion board tester has also been developed. The software consists of a collection of BASIC and assembly language routines developed on the test system microcomputer

  15. Development of an automatized device for eddy current testing

    International Nuclear Information System (INIS)

    David, B.; Benoist, B.; Champonnois, F.; Viard, J.

    1990-01-01

    To improve performances in eddy current studies, several tools were developed in the Saclay Laboratory: - ELEFANT is a very flexible software which allows a rapid creation of new NDT applications, preserving anytime a full compatibility between computers, applications, data... used under the same ELEFANT controlkey. - Modulo'STA is a modular hardware designed to be the flexible interface between the probe and the computer, driving the measurement, the probe movement... - rotating EC probes with local rotation facilities allow the control of very long steam generator tubes, even bent [fr

  16. Energy Systems Test Area (ESTA) Electrical Power Systems Test Operations: User Test Planning Guide

    Science.gov (United States)

    Salinas, Michael J.

    2012-01-01

    Test process, milestones and inputs are unknowns to first-time users of the ESTA Electrical Power Systems Test Laboratory. The User Test Planning Guide aids in establishing expectations for both NASA and non-NASA facility customers. The potential audience for this guide includes both internal and commercial spaceflight hardware/software developers. It is intended to assist their test engineering personnel in test planning and execution. Material covered includes a roadmap of the test process, roles and responsibilities of facility and user, major milestones, facility capabilities, and inputs required by the facility. Samples of deliverables, test article interfaces, and inputs necessary to define test scope, cost, and schedule are included as an appendix to the guide.

  17. Current control system for superconducting coils of LHD

    International Nuclear Information System (INIS)

    Chikaraishi, H.; Yamada, S.; Inoue, T.

    1996-01-01

    This paper introduce a coil current control system of the LHD. The main part of this system consists of two VME based real time computers and a risc based work station which are connected by optical fiber link. In this computer system, a coil current controller for steady state operation of LHD which based on a state variable control theory is installed. Also advanced current control scheme, which are now developing for dynamic current control in phase II operation of LHD, are introduced. (author)

  18. ANTIFUNGAL SUSCEPTIBILITY TESTING: CURRENT ROLE FROM THE CLINICAL LABORATORY PERSPECTIVE

    Directory of Open Access Journals (Sweden)

    Brunella Posteraro

    2014-04-01

    Full Text Available Despite availability of many antifungal agents, antifungal clinical resistance occurs, perhaps as a result of an infecting organism found to be resistant in vitro to one or more antifungals tested. Thus, antifungal susceptibility testing (AFST results, if timely generated by the clinical microbiology and communicated to clinicians, can aid them in the therapeutic decision making, especially for difficult-to-treat invasive candidiasis and aspergillosis. Although recently refined AFST methods are commercially available to allow a close antifungal resistance surveillance in many clinical setting, novel assays, relying on short-time antifungal drug exposure of fungal isolates, are upcoming tools for AFST. Based on emerging technologies such as flow cytometry, MALDI-TOF mass spectrometry, and isothermal microcalorimetry, these assays could provide a reliable means for quicker and sensitive assessment of AFST.

  19. Current Hypersonic and Space Vehicle Flight Test and Instrumentation

    Science.gov (United States)

    2015-06-22

    ground station hardware and software. B. Space- based Platforms There are already in place several satellite based options to collecting and... Transceive data over very long range at low to very high altitudes DARPA: XS-1 Ground Based Aircraft Based Space Based Future Data...412TW-PA-15264 AIR FORCE TEST CENTER EDWARDS AIR FORCE BASE , CALIFORNIA AIR FORCE MATERIEL COMMAND UNITED STATES AIR FORCE REPORT

  20. Current clinical trials testing combinations of immunotherapy and radiation.

    Science.gov (United States)

    Crittenden, Marka; Kohrt, Holbrook; Levy, Ronald; Jones, Jennifer; Camphausen, Kevin; Dicker, Adam; Demaria, Sandra; Formenti, Silvia

    2015-01-01

    Preclinical evidence of successful combinations of ionizing radiation with immunotherapy has inspired testing the translation of these results to the clinic. Interestingly, the preclinical work has consistently predicted the responses encountered in clinical trials. The first example came from a proof-of-principle trial started in 2001 that tested the concept that growth factors acting on antigen-presenting cells improve presentation of tumor antigens released by radiation and induce an abscopal effect. Granulocyte-macrophage colony-stimulating factor was administered during radiotherapy to a metastatic site in patients with metastatic solid tumors to translate evidence obtained in a murine model of syngeneic mammary carcinoma treated with cytokine FLT-3L and radiation. Subsequent clinical availability of vaccines and immune checkpoint inhibitors has triggered a wave of enthusiasm for testing them in combination with radiotherapy. Examples of ongoing clinical trials are described in this report. Importantly, most of these trials include careful immune monitoring of the patients enrolled and will generate important data about the proimmunogenic effects of radiation in combination with a variety of immune modulators, in different disease settings. Results of these studies are building a platform of evidence for radiotherapy as an adjuvant to immunotherapy and encourage the growth of this novel field of radiation oncology. Copyright © 2015 Elsevier Inc. All rights reserved.

  1. Partnership Opportunities with AFRC for Wireless Systems Flight Testing

    Science.gov (United States)

    Hang, Richard

    2015-01-01

    The presentation will overview the flight test capabilities at NASA Armstrong Flight Research Center (AFRC), to open up partnership collaboration opportunities for Wireless Community to conduct flight testing of aerospace wireless technologies. Also, it will brief the current activities on wireless sensor system at AFRC through SBIR (Small Business Innovation Research) proposals, and it will show the current areas of interest on wireless technologies that AFRC would like collaborate with Wireless Community to further and testing.

  2. Toward Intelligence Systems for Testing.

    Science.gov (United States)

    1987-03-01

    corresponding to [3]. The question posed to the student will end up being, 𔄁s the current at Meter A higher, lower, or the same as the current at Meter B1 " The...List [Pittsburgh/Lesgold] NR 4422539 Dr. Diane Damos ERIC Facility-Acquisitions Arizona State University 4833 Rugby Avenue Department of Psychology

  3. Testing lifting systems in nuclear facilities

    International Nuclear Information System (INIS)

    Kling, H.; Laug, R.

    1984-01-01

    Lifting systems in nuclear facilities must be inspected at regular intervals after having undergone their first acceptance test. These inspections are frequently carried out by service firms which not only employ the skilled personnel required for such jobs but also make available the necessary test equipment. The inspections in particular include a number of sophisticated load tests for which test load systems have been developed to allow lifting systems to be tested so that reactor specific boundary conditions are taken into account. In view of the large number of facilities to be inspected, the test load system is a modular system. (orig.) [de

  4. Increase of energy efficiency of testing of traction electric machines of direct and pulsating current

    Directory of Open Access Journals (Sweden)

    A.M. Afanasov

    2015-03-01

    Full Text Available The results of the analysis of the effect of the load current of traction electric machines when tested for heating on the total electricity consumption for the test are presented. It is shown that increase of load current at the heating test permits to significantly reduce the consumption of electrical energy, and reduce the testing time without reducing its quality.

  5. Theoretical and practical program in the non-destructive testing by eddy currents - the first level

    International Nuclear Information System (INIS)

    Shaaban, H.I.; Addarwish, J.M.A.

    2014-11-01

    The testing using eddy currents is one of the non-destructive tests that use electromagnetic property as a basis for testing procedures, and there are many other ways to use this principle, including Remote Field Testing and the Magnetic Flux Leakage test. Eddy currents are electrical currents moving in a circular path, and took the name eddy of eddies that form when a liquid or gas is moving in a circular path because of objection obstacles to its track. They are generated in the material using a variable magnetic field. Non-destructive testing by eddy currents is a technique used for the detection of defects and interruptions in a material and it is a process that relies on the generation of small eddy currents in the material of the part to be examined, provided that this part is of an electrically conducting material. This technique and its scientific basis are explained in this book. Also the devices used in this technique and how to use these devices in details are explained. The book contains Twelve chapters: Introduction to non destructive testing - Engineering materials and its mechanical characteristics - Electrical and magnetic characteristics of engineering materials - Introduction to testing by eddy currents - Factors affecting eddy currents - Basis of electrical circuits used in eddy currents testing devices - Probes of eddy currents testing - Eddy currents testing devices (Theoretical) - Analysis of the examination results of testing by eddy currents: techniques and applications - Applications of testing by eddy currents - Eddy currents testing devices (Application) - Practical lessons for the first level in testing by eddy currents.

  6. Current evidence for universal molecular testing for colorectal cancer patients

    Directory of Open Access Journals (Sweden)

    Fábio Guilherme Campos

    2017-07-01

    Full Text Available Background: Risk assessment for Lynch Syndrome may be a complex and challenging task. Demonstration of germline mutations has the benefits of confirming Lynch Syndrome diagnosis and may also provide screening and surgical orientation for affected members and relief for non-affected relatives. Objective: The present paper aimed to critically review the criteria to diagnose Lynch Syndrome, focusing the attention on the new perspective of adopting universal screening for patients diagnosed with colorectal cancer. Methods: We performed a literature review about the rationale and preliminary results of universal testing for Lynch Syndrome. Results: The use of selective eligibility criteria to determine who should undergo Lynch Syndrome testing may fail in a substantial proportion of cases. Moreover, universal strategy is feasible, cost-effective and more sensitive than previous methods. However, there still exist problems regarding clinical practice implementation and compliance either by medical doctors and patients. Conclusions: Standard guidelines for colorectal cancer screening are not ideal to provide early detection of Lynch Syndrome patients. And although universal screening has been associated with an increased identification of Lynch Syndrome patients, a successful implementation of this approach is still limited by the lack of clinical expertise among physicians, and also requires standardization of the existing protocols for routine genetic screening. Resumo: Introdução: A avaliação de risco para síndrome de Lynch (SL pode ser tarefa complexa e desafiadora. A demonstração de mutações na linha germinal resulta em benefícios, como a confirmação do diagnóstico de SL e também pode proporcionar orientações para a triagem e procedimentos cirúrgicos para os membros afetados, além de trazer alívio para os parentes não afetados. Objetivo: Este artigo teve por objetivo oferecer uma revisão crítica dos critérios para o diagn

  7. Control systems for ITER diagnostics, heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Simrock, Stefan, E-mail: stefan.simrock@iter.org

    2016-11-15

    The ITER Diagnostic, Heating and Current Drive systems might appear, on the face of it, to have very different control requirements. There are approximately 45 diagnostic systems, including magnetic sensors for plasma position and shape determination, imaging systems in the IR and visible, Thompson scattering for electron temperature and density, neutron detectors and collective scattering for alpha particle density and energy distribution. The H&CD systems encompass Electron Cyclotron Heating, using 24 1MW, 170 GHz gyrotrons and 5 steerable launchers to deliver 20 MW to the plasma, Ion Cyclotron Heating, using 8 3MW, 40–55 MHz sources and two multi-element launchers to deliver 20 MW to the plasma, and 2 Negative Ion Neutral Beam Injectors, each of which can deliver up to 16.5 MW of 1 MeV beams to the plasma. Although there are substantial differences in the needs for protection, when handling multi-MW heating systems, and in data throughput for many diagnostics, the formal processes needed to translate system requirements into Instrumentation and Control are identical. Due to the distributed procurement of ITER sub-systems and the need to integrate as painlessly as possible to CODAC, the formal processes, together with a substantial degree of standardization, are even more than usually essential. Starting from the technical, safety and protection, integration and operation requirements, a loop of functional analysis and signal listing is used to generate the controller configuration and the conceptual architecture. These elements in their turn lead to the physical and software design. The paper will describe the formal processes of control system design and the methods used by the ITER project to achieve the standardization of systems engineering practices. These have been applied to several use-cases covering all operation relevant phases such as plasma operation, maintenance, testing and conditioning. There are a number of running contracts that are developing

  8. Evaluation of advanced and current leak detection systems

    International Nuclear Information System (INIS)

    Kupperman, D.S.

    1988-01-01

    U.S. Nuclear Regulatory Commission Guide 1.45 recommends the use of at least three different detection methods in reactors to detect leakage. Monitoring of both sump-flow and airborne particulate radioactivity is mandatory. A third method can involve either monitoring of condensate flow rate from air coolers or monitoring of airborne gaseous radioactivity. Although the methods currently used for leak detection reflect the state of the art, other techniques may be developed and used. Since the recommendations of Regulatory Guide 1.45 are not mandatory, Licensee Event Report Compilations have been reviewed to help establish actual capabilities for leak detection. The review of event reports, which had previously covered the period of June 1985 to August 1986 has been extended, and now covers events to June 1987. The total number of significant events is now 83. These reports have provided documented, sometimes detailed, summaries of reactor leaks. They have helped establish the capabilities of existing systems to detect and locate leaks. Differences between PWRs and BWRs with regard to leak detection have now been analyzed. With regard to detection methods, the greatest differences between reactor types are as follows: (a) The sump pump is reported as the detection method more frequently in BWRs than in PWRs (64% vs. 35%). (b) The radiation monitor is reported as the detection method (excluding false alarms) more frequently in PWRs. Current efforts at Argonne National Laboratory (ANL) to evaluate advanced acoustic leak detection methods are directed toward the generation and analysis of acoustic data from large (0.5 to 10 gal/min) leaks and modification of the software of the GARD/ANL advanced acoustic leak detection system. In order to reach the goal of 10 gal/min leaks, the Steam Generator Test Facility at ANL has been modified to carry out the leak testing. Tests were carried out with water at 525 deg. F and 1100 psi leaking through a fatigue crack in a 4-in

  9. System for evaluating weld quality using eddy currents

    Science.gov (United States)

    Todorov, Evgueni I.; Hay, Jacob

    2017-12-12

    Electromagnetic and eddy current techniques for fast automated real-time and near real-time inspection and monitoring systems for high production rate joining processes. An eddy current system, array and method for the fast examination of welds to detect anomalies such as missed seam (MS) and lack of penetration (LOP) the system, array and methods capable of detecting and sizing surface and slightly subsurface flaws at various orientations in connection with at least the first and second weld pass.

  10. Application of numerical analysis techniques to eddy current testing for steam generator tubes

    International Nuclear Information System (INIS)

    Morimoto, Kazuo; Satake, Koji; Araki, Yasui; Morimura, Koichi; Tanaka, Michio; Shimizu, Naoya; Iwahashi, Yoichi

    1994-01-01

    This paper describes the application of numerical analysis to eddy current testing (ECT) for steam generator tubes. A symmetrical and three-dimensional sinusoidal steady state eddy current analysis code was developed. This code is formulated by future element method-boundary element method coupling techniques, in order not to regenerate the mesh data in the tube domain at every movement of the probe. The calculations were carried out under various conditions including those for various probe types, defect orientations and so on. Compared with the experimental data, it was shown that it is feasible to apply this code to actual use. Furthermore, we have developed a total eddy current analysis system which consists of an ECT calculation code, an automatic mesh generator for analysis, a database and display software for calculated results. ((orig.))

  11. Permanent spin currents in cavity-qubit systems

    Science.gov (United States)

    Kulkarni, Manas; Hein, Sven M.; Kapit, Eliot; Aron, Camille

    2018-02-01

    In a recent experiment [P. Roushan et al., Nat. Phys. 13, 146 (2017), 10.1038/nphys3930], a spin current in an architecture of three superconducting qubits was produced during a few microseconds by creating synthetic magnetic fields. The lifetime of the current was set by the typical dissipative mechanisms that occur in those systems. We propose a scheme for the generation of permanent currents, even in the presence of such imperfections, and scalable to larger system sizes. It relies on striking a subtle balance between multiple nonequilibrium drives and the dissipation mechanisms, in order to engineer and stimulate chiral excited states which can carry current.

  12. TMACS Test Procedure TP007: System administration

    International Nuclear Information System (INIS)

    Scanlan, P.; Washburn, S.; Seghers, R.

    1994-01-01

    The TMACS Software Project Test Procedures translate the project's acceptance criteria into test steps. Software releases are certified when the affected Test Procedures are successfully performed and the customers authorize installation of these changes. This Test Procedure tests the TMACS System Administration functions

  13. Tritium systems test assembly stabilization

    International Nuclear Information System (INIS)

    Jasen, William G.; Michelotti, Roy A.; Anast, Kurt R.; Tesch, Charles

    2004-01-01

    The Tritium Systems Test Assembly (TSTA) was a facility dedicated to tritium technology Research and Development (R and D) primarily for future fusion power reactors. The facility was conceived in mid 1970's, operations commenced in early 1980's, stabilization and deactivation began in 2000 and were completed in 2003. The facility will remain in a Surveillance and Maintenance (S and M) mode until the Department of Energy (DOE) funds demolition of the facility, tentatively in 2009. A safe and stable end state was achieved by the TSTA Facility Stabilization Project (TFSP) in anticipation of long term S and M. At the start of the stabilization project, with an inventory of approximately 140 grams of tritium, the facility was designated a Hazard Category (HC) 2 Non-Reactor Nuclear facility as defined by US Department of Energy standard DOE-STD-1027-92 (1997). The TSTA facility comprises a laboratory area, supporting rooms, offices and associated laboratory space that included more than 20 major tritium handling systems. The project's focus was to reduce the tritium inventory by removing bulk tritium, tritiated water wastes, and tritium-contaminated high-inventory components. Any equipment that remained in the facility was stabilized in place. All of the gloveboxes and piping were rendered inoperative and vented to atmosphere. All equipment, and inventoried tritium contamination, remaining in the facility was left in a safe-and-stable state. The project used the End Points process as defined by the DOE Office of Environmental Management (web page http://www.em.doe.- gov/deact/epman.htmtlo) document and define the end state required for the stabilization of TSTA Facility. The End Points process added structure that was beneficial through virtually all phases of the project. At completion of the facility stabilization project the residual tritium inventory was approximately 3,000 curies, considerably less than the 1.6-gram threshold for a HC 3 facility. TSTA is now

  14. Current development of UAV sense and avoid system

    Science.gov (United States)

    Zhahir, A.; Razali, A.; Mohd Ajir, M. R.

    2016-10-01

    As unmanned aerial vehicles (UAVs) are now gaining high interests from civil and commercialised market, the automatic sense and avoid (SAA) system is currently one of the essential features in research spotlight of UAV. Several sensor types employed in current SAA research and technology of sensor fusion that offers a great opportunity in improving detection and tracking system are presented here. The purpose of this paper is to provide an overview of SAA system development in general, as well as the current challenges facing UAV researchers and designers.

  15. Testing Digital Electronic Protection Systems

    CERN Document Server

    Gabourin, S

    2011-01-01

    This paper outlines the core concepts and realisation of the Safe Machine Parameters Controller (SMPC) testbench, based on a VME crate and LabVIEW program. Its main goal is to ensure the correct function of the SMPC for the protection of the CERN accelerator complex. To achieve this, the tester has been built to replicate the machine environment and operation, in order to ensure that the chassis under test is completely exercised. The complexity of the task increases with the number of input combinations. This paper also outlines the benefits and weaknesses of developing a test suite independently of the hardware being tested, using the “V” approach.

  16. Preoperational test report, primary ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  17. Preoperational test report, primary ventilation system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Primary Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space filtered venting of tanks AY101, AY102, AZ101, AZ102. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  18. Preoperational test report, vent building ventilation system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Vent Building Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides Heating, Ventilation, and Air Conditioning (HVAC) for the W-030 Ventilation Building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  19. Peculiarities of the risk management system organization in current conditions

    OpenAIRE

    MIKHIN P.O.

    2014-01-01

    Risk-management system organization problem is topical nowadays. The innovation activity is defined as an activity vulnerable to risk and needs more attention. The basic approaches and elements of organization structure development in risk-management system are considered to find out the best structure for business modelling usage. Balance and combination of risk-management system types are required in current conditions.

  20. A Short-Current Control Method for Constant Frequency Current-Fed Wireless Power Transfer Systems

    Directory of Open Access Journals (Sweden)

    Yanling Li

    2017-04-01

    Full Text Available Frequency drift is a serious problem in Current-Fed Wireless Power Transfer (WPT systems. When the operating frequency is drifting from the inherent Zero Voltage Switching (ZVS frequency of resonant network, large short currents will appear and damage the switches. In this paper, an inductance-dampening method is proposed to inhibit short currents and achieve constant-frequency operation. By adding a small auxiliary series inductance in the primary resonant network, short currents are greatly attenuated to a safe level. The operation principle and steady-state analysis of the system are provided. An overlapping time self-regulating circuit is designed to guarantee ZVS running. The range of auxiliary inductances is discussed and its critical value is calculated exactly. The design methodology is described and a design example is presented. Finally, a prototype is built and the experimental results verify the proposed method.

  1. Qualification and testing of CT systems

    DEFF Research Database (Denmark)

    Bartscher, Markus; Neuschaefer-Rube, Ulrich; Illemann, Jens

    2018-01-01

    This chapter focuses on system verification and conformance to specifications. System qualification is carried out to ensure that the system and itscomponents achieve the best performance—usually corresponding to the specificationsmade by the manufacturer. Acceptance and reverification testing ar...

  2. Electromagnetic Environmental Effects System Testing

    Science.gov (United States)

    2009-09-02

    Frequency List for Ground Systems. Frequency (MHz) Polarization (POL) Modulation (MOD) Electric Field Intensity V/m 3.03 V AM 50 4 V AM 50...21 September 2009 B-6 Table B-2. Sample External RF EME Frequency List for Ground Systems. Frequency (MHz) Polarization (POL) Modulation...438 V/H AM/FM/PM 50 TOP 1-2-511 21 September 2009 B-7 Table B-2. Sample External RF EME Frequency List for Ground Systems. Frequency (MHz

  3. Energy Systems High-Pressure Test Laboratory | Energy Systems Integration

    Science.gov (United States)

    Facility | NREL Energy Systems High-Pressure Test Laboratory Energy Systems High-Pressure Test Laboratory In the Energy Systems Integration Facility's High-Pressure Test Laboratory, researchers can safely test high-pressure hydrogen components. Photo of researchers running an experiment with a hydrogen fuel

  4. The study of human bodies' impedance networks in testing leakage currents of electrical equipments

    Science.gov (United States)

    Zhang, Zhaohui; Wang, Xiaofei

    2006-11-01

    In the testing of electrical equipments' leakage currents, impedance networks of human bodies are used to simulate the current's effect on human bodies, and they are key to the preciseness of the testing result. This paper analyses and calculates three human bodies' impedance networks of measuring electric burn current, perception or reaction current, let-go current in IEC60990, by using Matlab, compares the research result of current effect thresholds' change with sine wave's frequency published in IEC479-2, and amends parameters of measuring networks. It also analyses the change of perception or reaction current with waveform by Multisim.

  5. Comparative study on current trading system and online trading: the ...

    African Journals Online (AJOL)

    Comparative study on current trading system and online trading: the case of ... of online trading and factors affecting its feasibility of implementation in ECX. ... The study found that there is significant capacity problem with major skills gap with ...

  6. Minicomputer controlled test system for process control and monitoring systems

    International Nuclear Information System (INIS)

    Worster, L.D.

    A minicomputer controlled test system for testing process control and monitoring systems is described. This system, in service for over one year, has demonstrated that computerized control of such testing has a real potential for expanding the scope of the testing, improving accuracy of testing, and significantly reducing the time required to do the testing. The test system is built around a 16-bit minicomputer with 12K of memory. The system programming language is BASIC with the addition of assembly level routines for communication with the peripheral devices. The peripheral devices include a 100 channel scanner, analog-to-digital converter, visual display, and strip printer. (auth)

  7. Testing Infrastructure for Operating System Kernel Development

    DEFF Research Database (Denmark)

    Walter, Maxwell; Karlsson, Sven

    2014-01-01

    Testing is an important part of system development, and to test effectively we require knowledge of the internal state of the system under test. Testing an operating system kernel is a challenge as it is the operating system that typically provides access to this internal state information. Multi......-core kernels pose an even greater challenge due to concurrency and their shared kernel state. In this paper, we present a testing framework that addresses these challenges by running the operating system in a virtual machine, and using virtual machine introspection to both communicate with the kernel...... and obtain information about the system. We have also developed an in-kernel testing API that we can use to develop a suite of unit tests in the kernel. We are using our framework for for the development of our own multi-core research kernel....

  8. Test software for BESIII MDC electronics system

    International Nuclear Information System (INIS)

    Zhang Hongyu; Sheng Huayi; Zhu Haitao; Ji Xiaolu; Zhao Dongxu

    2006-01-01

    This paper presents the design of Test System Software for BESIII MDC Electronics. Two kinds of test systems, SBS VP7 based and PowerPC based systems, and their corresponding test software are introduced. The software is developed in LabVIEW 7.1 and Microsoft Visual C++ 6.0, some test functions of the software, as well as their user interfaces, are described in detail. The software has been applied in hardware debugging, performance test and long term stability test. (authors)

  9. Testing cooperative systems with the MARS simulator

    NARCIS (Netherlands)

    Netten, B.D.; Wedemeijer, H.

    2010-01-01

    The complexity of cooperative systems makes the use of high fidelity simulation essential in the development and testing of cooperative applications and their interactions with other cooperative systems. In SAFESPOT a simulator test bench is setup to test the safety margin applications running on

  10. Operational test report integrated system test (ventilation upgrade)

    Energy Technology Data Exchange (ETDEWEB)

    HARTY, W.M.

    1999-10-05

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, Ay102, AZ101, AZ102.

  11. Operational test report, integrated system test (ventilation upgrade)

    International Nuclear Information System (INIS)

    HARTY, W.M.

    1999-01-01

    Operational Final Test Report for Integrated Systems, Project W-030 (Phase 2 test, RECIRC and HIGH-HEAT Modes). Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks, including upgraded vapor space cooling and filtered venting of tanks AY101, AY102, AZ101, AZ102

  12. TTCN-3 for distributed testing embedded systems

    NARCIS (Netherlands)

    Blom, S.C.C.; Deiß, T.; Ioustinova, N.; Kontio, A.; Pol, van de J.C.; Rennoch, A.; Sidorova, N.; Virbitskaite, I.; Voronkov, A.

    2007-01-01

    Abstract. TTCN-3 is a standardized language for specifying and executing test suites that is particularly popular for testing embedded systems. Prior to testing embedded software in a target environment, the software is usually tested in the host environment. Executing in the host environment often

  13. Railcar waste transfer system hydrostatic test report

    International Nuclear Information System (INIS)

    Ellingson, S.D.

    1997-01-01

    This Acceptance Test Report (ATR) documents for record purposes the field results, acceptance, and approvals of the completed acceptance test per HNF-SD-W417-ATP-001, ''Rail car Waste Transfer System Hydrostatic Test''. The test was completed and approved without any problems or exceptions

  14. Simulating lightning tests to radar system

    NARCIS (Netherlands)

    Blaj, M.A.; Buesink, Frederik Johannes Karel; Leferink, Frank Bernardus Johannes

    2010-01-01

    The risk of destruction due to lightning makes simulating the effects of lightning strikes a necessity. We modeled a radar enclosure and simulated the effect of a lightning strike. The results have been validated using full threat lightning current tests.

  15. The current situation and development of medical device testing institutes in China.

    Science.gov (United States)

    Yang, Xiaofang; Mu, Ruihong; Fan, Yubo; Wang, Chunren; Li, Deyu

    2017-04-01

    This article analyses the current situation and development of Chinese medical device testing institutes from the perspectives of the two most important functions - testing functions and medical device standardization functions. Areas Covered: The objective of the Chinese government regulations for medical device industry is to ensure the safety and effectiveness of medical devices for Chinese patients. To support the regulation system, the Chinese government has established medical device testing institutes at different levels for example, the national, provincial, and municipal levels. These testing institutes also play an important role in technical support during medical device premarket registration and post market surveillance, they are also the vital practitioners of Chinese medical device standardization. Expert Commentary: Chinese medical device testing institutes are technical departments established by government, and serve the regulatory functions of government agency. In recent years, with the rapid development of medical device industry as well as constantly increasing international and domestic medical device market, the importance of medical device testing institute is more prominent, However, there are still some problems unsolved, such as their overall capacity remains to be improved, construction of standardization is to be strengthened, etc.

  16. Cooperative Testing of Uncontrollable Timed Systems

    DEFF Research Database (Denmark)

    David, Alexandre; Larsen, Kim Guldstrand; Li, Shuhao

    2008-01-01

    the SUT against the test purpose as long as the SUT reacts to our moves in a cooperative style. We present an operational framework of cooperative winning strategy generation, test case derivation and execution. The test method is proved to be sound and complete. Preliminary experimental results indicate......Abstract. This paper deals with targeted testing of timed systems with uncontrollable behavior. The testing activity is viewed as a game between the tester and the system under test (SUT) towards a given test purpose. The SUT is modeled as Timed Game Automaton and the test purpose is specified...... in Timed CTL formula. We can employ a timed game solver UPPAAL-TIGA to check if the test purpose is ture w.r.t. the model, and if yes, to generate a winning strategy and use it for black-box conformance testing. Specifically, we show that in case the checking yields a negative result, we can still test...

  17. Vitrification Facility integrated system performance testing report

    International Nuclear Information System (INIS)

    Elliott, D.

    1997-01-01

    This report provides a summary of component and system performance testing associated with the Vitrification Facility (VF) following construction turnover. The VF at the West Valley Demonstration Project (WVDP) was designed to convert stored radioactive waste into a stable glass form for eventual disposal in a federal repository. Following an initial Functional and Checkout Testing of Systems (FACTS) Program and subsequent conversion of test stand equipment into the final VF, a testing program was executed to demonstrate successful performance of the components, subsystems, and systems that make up the vitrification process. Systems were started up and brought on line as construction was completed, until integrated system operation could be demonstrated to produce borosilicate glass using nonradioactive waste simulant. Integrated system testing and operation culminated with a successful Operational Readiness Review (ORR) and Department of Energy (DOE) approval to initiate vitrification of high-level waste (HLW) on June 19, 1996. Performance and integrated operational test runs conducted during the test program provided a means for critical examination, observation, and evaluation of the vitrification system. Test data taken for each Test Instruction Procedure (TIP) was used to evaluate component performance against system design and acceptance criteria, while test observations were used to correct, modify, or improve system operation. This process was critical in establishing operating conditions for the entire vitrification process

  18. Caustic addition system operability test procedure

    Energy Technology Data Exchange (ETDEWEB)

    Parazin, R.E.

    1994-11-01

    This test procedure provides instructions for performing operational testing of the major components of the 241-AN-107 Caustic Addition System by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E).

  19. Caustic addition system operability test procedure

    International Nuclear Information System (INIS)

    Parazin, R.E.

    1994-11-01

    This test procedure provides instructions for performing operational testing of the major components of the 241-AN-107 Caustic Addition System by WHC and Kaiser personnel at the Rotating Equipment Shop run-in pit (Bldg. 272E)

  20. Active control system upgrade design for lower hybrid current drive system on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Kanojia, A.D., E-mail: akanojia@mit.edu [Massachusetts Institute of Technology Plasma Science and Fusion Center, Cambridge, MA (United States); Wallace, G.M.; Terry, D.R.; Stillerman, J.A.; Burke, W.M.; MacGibbon, P.A.; Johnson, D.K. [Massachusetts Institute of Technology Plasma Science and Fusion Center, Cambridge, MA (United States)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Initial tests of the Hittite microwave components show good or better control of phase and amplitude when compared to the vector modulators used in the current system. Black-Right-Pointing-Pointer With an analog based control component system the system complexity is dramatically reduced. Black-Right-Pointing-Pointer Historically, D-tAcq hardware/software has performed more reliably on DPCS and FFT controllers than the current lower hybrid control system Black-Right-Pointing-Pointer Cost and lead time of the Hittite microwave components is significantly small compared to vector modulators. - Abstract: As a part of the scheduled expansion of the Alcator C-Mod lower hybrid current drive (LHCD) system from 12 to 16 klystrons to accommodate installation of a second LH antenna, the active control system (ACS) is being redesigned to accommodate the additional klystrons. Digitizers and output modules will be cPCI modules provided by D-tAcq Solutions. The real-time application will run on a standard PC server running Linux. Initially, the new ACS system will be designed to control 8 klystrons on the second LH antenna and the existing ACS will control the remaining 8 klystrons on the existing LH antenna. Experience gained operating the existing LHCD system has given us insight into the design of a more robust, compact, efficient and simple system for the new ACS. The design upgrade will be patterned on the digital plasma control system (DPCS [1]) in use on C-Mod.

  1. High Power Alternator Test Unit (ATU) Electrical System Test

    Science.gov (United States)

    Birchenough, Arthur; Hervol, David

    2007-01-01

    The Alternator Test Unit (ATU) in the Lunar Power System Facility (LPSF) located at the NASA Glenn Research Center (GRC) in Cleveland, OH was used to simulate the operating conditions and evaluate the performance of the ATU and it s interaction with various LPSF components in accordance with the JIMO AC Power System Requirements. The testing was carried out at the breadboard development level. Results of these tests will be used for the development and validation of analytical models for performance and lifetime prediction.

  2. Eddy current testing on structures of nuclear-grade IG-110 graphite for acceptance test in HTTR

    International Nuclear Information System (INIS)

    Ishihara, Masahiro; Saikusa, Akio; Iyoku, Tatsuo

    1993-09-01

    Core and core support graphite structures in the HTTR are mainly made of IG-110 graphite which is fine-grained isotropic and nuclear-grade. Nondestructive inspection with eddy current testing is planned to be applied to these graphite structures. Eddy current testing is widely applied to metallic structures and its testing method has been already established. On the other hand, the characteristics of graphite are quite different in micro-structure from these of metals. Therefore, the eddy current testing method provided for metallic structures can not be applied directly to graphite structures. Thus the eddy current testing method and condition were established for the graphite structures made of IG-110 graphite. (author)

  3. Polymer systems testing: Final report

    International Nuclear Information System (INIS)

    1993-01-01

    Los Alamos National Laboratory (LANL) is in the process of decontaminating lead shielding material. The procedure involves abrasive surface etching of the shielding to remove the outer layer of lead that contains the majority of the radioactive contaminants. This procedure generates a small volume of mixed waste in the form of a wet residue containing lead, abrasive grit (Al 2 O 3 ), uranium and water. IC Technologies, Inc. (ICT) has developed several processes for the treatment of mixed wastes involving stabilizing/encapsulating the waste in a polymer monolith. The objective of the test program was to verify the applicability of ICT's technology to this specific waste stream and provide LANL baseline data on the performance of polymer encapsulation techniques. Polymer microencapsulation of lead shielding/blasting grit (surrogate) mixed waste was evaluated. Two polymers, melamine formaldehyde and polyester xylene, were used to examine the effect of waste loading on Toxicity Characteristic Leaching Procedure (TCLP) extract Pb concentration. Six levels of waste loading were evaluated by eleven tests. Significant reduction in Pb solubility during TCLP was achieved. Additional optimization to the single-stage microencapsulation technique utilized will be necessary to mitigate the toxic (RCRA) characteristic of the waste

  4. System for testing optical fibers

    Science.gov (United States)

    Golob, John E. [Olathe, KS; Looney, Larry D. [Los Alamos, NM; Lyons, Peter B. [Los Alamos, NM; Nelson, Melvin A. [Santa Barbara, CA; Davies, Terence J. [Santa Barbara, CA

    1980-07-15

    A system for measuring a combination of optical transmission properties of fiber optic waveguides. A polarized light pulse probe is injected into one end of the optical fiber. Reflections from discontinuities within the fiber are unpolarized whereas reflections of the probe pulse incident to its injection remain polarized. The polarized reflections are prevented from reaching a light detector whereas reflections from the discontinuities reaches the detector.

  5. Chemical sensing underclothing system for testing PPE

    International Nuclear Information System (INIS)

    Slabotinsky, J.; Kralik, L.; Bradka, S.; Castulik, P.

    2009-01-01

    Personal protective equipment (PPE) when worn is subjected to pressure differentials across the garment due to ambient wind flow, by body movement and breathing creating the bellows effect, which may force hazardous chemicals vapor or aerosol through the closures, joints, outlet valves and/or clothing protective fabric. Thus the design, fit, size or improper donning of the protective garment will influence chemical-agent penetration. In order to determine penetration of chemical-protective garments by chemical vapor or aerosol, it is necessary to test the entire suit system, including seams, closures, outlet valves and areas of transition with other protective equipment, that is, at the ankles, waist, wrists, neck etc. In order to identify penetration of chemical vapor or aerosol through protective assembly, the Man-in-Simulant Test (MIST) with passive adsorptive devices (PADs) is used, when adsorbed challenging agent (simulant) is desorbed from the PAD and quantified. The current MIST method is failing in complexity of leak detection, due to limited number of passive collection points fixed on human body or a mannequin and very labor extensive work associated with allocation of 20-40 PADs and quantification of adsorbed agent. The Czech approach to detect and quantify penetration/permeation of chemical agent is based on chemical sensing underclothing enable to change the color when exposed with simulant or even with real CW agent. Color intensity and shape of stains on sensing fabric are processed with Laboratory Universal Computer Image Analysis (LUCIA) allowing determining the quantity and the allocation of the penetrating noxious agent(s). This method allows for example calculate individual doses of exposure, the breakthrough coefficient of protective garment as whole and uniquely precise allocation of penetration/permeation shortfalls. Presentation is providing detailed description of imaging system with nickname 'LUCY' in combination with testing mannequin

  6. A listening test system for automative audio

    DEFF Research Database (Denmark)

    Bech, Søren; Gulbol, Mehmet-Ali; Martin, Geoff

    2005-01-01

    This paper describes two listening tests that were performed to provide initial validation of an auralisation system (see Part 1) to mimic the acoustics of a car interior. The validation is based on a comparison of results from an in-car listening test and another test using the auralisation system...... and recordings of the stimuli used for the in-car test. The music samples for the test were chosen from a database of various CODEC examples from a previous extensive ITU test to validate the ITU-R BS.1387-1 standard....

  7. Bow Shock Generator Current Systems: MMS Observations of Possible Current Closure

    Science.gov (United States)

    Hamrin, M.; Gunell, H.; Lindkvist, J.; Lindqvist, P.-A.; Ergun, R. E.; Giles, B. L.

    2018-01-01

    We use data from the first two dayside seasons of the Magnetospheric Multiscale (MMS) mission to study current systems associated with quasi-perpendicular bow shocks of generator type. We have analyzed 154 MMS bow shock crossings near the equatorial plane. We compute the current density during the crossings and conclude that the component perpendicular to the shock normal (J⊥) is consistent with a pileup of the interplanetary magnetic field (IMF) inside the magnetosheath. For predominantly southward IMF, we observe a component Jn parallel (antiparallel) to the normal for GSM Y > 0 (MMS probing region. For IMF clock angles near 90∘, we find indications of the current system being tilted toward the north-south direction, obtaining a significant Jz component, and we suggest that the current closes off the equatorial plane at higher latitudes where the spacecraft are not probing. The observations are complicated for several reasons. For example, variations in the solar wind and the magnetospheric currents and loads affect the closure, and Jn is distributed over large regions, making it difficult to resolve inside the magnetosheath proper.

  8. A study on the chemical cleaning process and its qualification test by eddy current testing

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Ki Seok; Cheon, Keun Young; Nam, Min Woo [KHNP Central Research Institute, Daejeon (Korea, Republic of); Min, Kyoung Mahn [UMI Inc., Daejeon (Korea, Republic of)

    2013-12-15

    Steam Generator (SG) tube, as a barrier isolating the primary coolant system from the secondary side of nuclear power plants (NPP), must maintain the structural integrity for the public safety and their efficient power generation. So, SG tubes are subject to the periodic examination and the repairs if needed so that any defective tubes are not in service. Recently, corrosion related degradations were detected in the tubes of the domestic OPR-1000 NPP, as a form of axially oriented outer diameter stress corrosion cracking (ODSCC). According to the studies on the factors causing the heat fouling as well as developing corrosion cracking, densely scaled deposits on the secondary side of the SG tubes are mainly known to be problematic causing the adverse impacts against the soundness of the SG tubes. Therefore, the processes of various cleaning methods efficiently to dissolve and remove the deposits have been applied as well as it is imperative to maintain the structural integrity of the tubes after exposing to the cleaning agent. So qualification test (QT) should be carried out to assess the perfection of the chemical cleaning and QT is to apply the processes and to do ECT. In this paper, the chemical cleaning processes to dissolve and remove the scaled deposits are introduced and results of ECT on the artificial crack specimens to determine the effectiveness of those processes are represented.

  9. Test result communication in primary care: a survey of current practice.

    Science.gov (United States)

    Litchfield, Ian; Bentham, Louise; Lilford, Richard; McManus, Richard J; Hill, Ann; Greenfield, Sheila

    2015-11-01

    The number of blood tests ordered in primary care continues to increase and the timely and appropriate communication of results remains essential. However, the testing and result communication process includes a number of participants in a variety of settings and is both complicated to manage and vulnerable to human error. In the UK, guidelines for the process are absent and research in this area is surprisingly scarce; so before we can begin to address potential areas of weakness there is a need to more precisely understand the strengths and weaknesses of current systems used by general practices and testing facilities. We conducted a telephone survey of practices across England to determine the methods of managing the testing and result communication process. In order to gain insight into the perspectives from staff at a large hospital laboratory we conducted paired interviews with senior managers, which we used to inform a service blueprint demonstrating the interaction between practices and laboratories and identifying potential sources of delay and failure. Staff at 80% of practices reported that the default method for communicating normal results required patients to telephone the practice and 40% of practices required that patients also call for abnormal results. Over 80% had no fail-safe system for ensuring that results had been returned to the practice from laboratories; practices would otherwise only be aware that results were missing or delayed when patients requested results. Persistent sources of missing results were identified by laboratory staff and included sample handling, misidentification of samples and the inefficient system for collating and resending misdirected results. The success of the current system relies on patients both to retrieve results and in so doing alert staff to missing and delayed results. Practices appear slow to adopt available technological solutions despite their potential for reducing the impact of recurring errors in the

  10. Introducing an ophthalmic testing system

    Directory of Open Access Journals (Sweden)

    Jian-Zhuo Chen

    2013-07-01

    Full Text Available AIM: To integrate the individual and various items of refractive examination to one software, and made it applicated conveniently.METHODS: On the basis of every examination system, the computer software was designed and developed, the modules were established and maintained.RESULTS: The computer software could fulfill the examinations of visual acuity, strabismus(Hess screen, color vision, stereopsis.CONCLUSION: After 10 years' application, the effect is significant. It can nearly replace the items using projector of integrated refractometer, stereopsis exam and color blind exam.

  11. Gas characterization system software acceptance test procedure

    International Nuclear Information System (INIS)

    Vo, C.V.

    1996-01-01

    This document details the Software Acceptance Testing of gas characterization systems. The gas characterization systems will be used to monitor the vapor spaces of waste tanks known to contain measurable concentrations of flammable gases

  12. Gas characterization system software acceptance test report

    International Nuclear Information System (INIS)

    Vo, C.V.

    1996-01-01

    This document details the results of software acceptance testing of gas characterization systems. The gas characterization systems will be used to monitor the vapor spaces of waste tanks known to contain measurable concentrations of flammable gases

  13. Safety testing for LHC access system

    CERN Document Server

    Valentini, F; Ninin, P; Scibile, S

    2008-01-01

    In the domain of Safety Real-Time Systems the problem of testing represents always a big effort in terms of time, costs and efficiency to guarantee an adequate coverage degree. Exhaustive tests may, in fact, not be practicable for large and distributed systems. This paper describes the testing process followed during the validation of the CERN's LHC Access System [1], responsible for monitoring and preventing physical risks for the personnel accessing the underground areas. In the paper we also present a novel strategy for the testing problem, intended to drastically reduce the time for the test patterns generation and execution. In particular, we propose a methodology for blackbox testing that relies on the application of Model Checking techniques. Model Checking is a formal method from computer science, commonly adopted to prove correctness of system’s models through an automatic system’s state space exploration against some property formulas.

  14. LHCb : Full Experiment System Test

    CERN Multimedia

    Cattaneo, M

    2009-01-01

    LHCb had been planning to commission its High Level Trigger software and Data Quality monitoring procedures using real collisions data from the LHC pilot run. Following the LHC incident on 19th September 2008, it was decided to commission the system using simulated data. This “Full Experiment System Test” consists of: - Injection of simulated minimum bias events into the full HLT farm, after selection by a simulated Level 0 trigger. - Processing in the HLT farm to achieve the output rate expected for nominal LHC luminosity running, sustained over the typical duration of an LHC fill. - Real time Data Quality validation of the HLT output, validation of calibration and alignment parameters for use in the reconstruction. - Transmission of the event data, calibration data and book-keeping information to Tier1 sites and full reconstruction of the event data. - Data Quality validation of the reconstruction output. We will report on the preparations and results of FEST09, and on the status of commissioning for no...

  15. Excitation system testing in HPP 'Uvac'

    Directory of Open Access Journals (Sweden)

    Milojčić Nemanja

    2011-01-01

    Full Text Available The excitation system of hydro unit in HPP 'Uvac' and results of testings of excitation system performed for achieving of unit's mathematical model are presented in this paper. Description of excitation system equipment, parameters of regulators and results obtained after testings are presented. The presented results showed that the regulators are properly adjusted and that the excitation system is completely functional and reliable.

  16. A Review of Material Properties Estimation Using Eddy Current Testing and Capacitor Imaging

    Directory of Open Access Journals (Sweden)

    Mohd. Amri Yunus

    2009-01-01

    Full Text Available he non destructive testing applications based on inductive (eddy current testing and capacitive sensors are widely used for imaging of material properties. The simple structure, safe to use, low cost, non contact application, good response at medium range frequency of the sensors make them preferable to be used in the industries. The aim of this study is to talk about the material properties estimation applications using eddy current testing and capacitive sensing. The basic operations of eddy current testing and capacitive sensing with example of application in the non destructive testing are discussed. Next, the recent advancements of eddy current testing and capacitive testing in imaging technique are presented in this paper.

  17. Automation of eddy current system for in-service inspection of turbine and generator bores

    International Nuclear Information System (INIS)

    Viertl, J.R.M.

    1988-01-01

    The most commonly applied inspection method for ferromagnetic turbine and generator rotor bores is the magnetic particle test technique. This method is subjective, depends on the test operator's skill and diligence in identifying test indications, and suffers from poor repeatability, especially for small indications. Automation would improve repeatability. However, magnetic particle tests are not easily automated, because the data are in the form of sketches, photographs, and written and oral descriptions of the indications. Eddy current inspection has obvious potential to replace magnetic particle methods in this application. Eddy current tests can be readily automated, as the data are in the form of voltages that can be recorded, digitized, and manipulated by a computer. The current project continues the investigation of the correlation between eddy current and magnetic particle inspection. Two systems have been combined to acquire eddy current data automatically. This combination of systems consists of the Nortec-25L Eddyscope (to provide the analog eddy current signals) and the General Electric DATAQ (TM) System (to perform the automatic data acquisition). The automation of the system is discussed

  18. A/T test system for production line; Seisan line yo A/T test system

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-10

    This paper introduces an A/T test system for production line made by Meidensha, Inc. Rates and technology of mounting auto-transmissions (A/T) in recent automobiles are improving year after year. A/T production line testers were fabricated and supplied, including those for European countries. This system has the following features: the system employs low inertia AC motor, and is capable of performing tests in close conditions to actual cars; an insulated gate bipolar transistor (IGBT) inverter was employed to achieve control accuracy improvement and noise reduction; high-velocity transient measurement is possible by using a computer system based on the WindowsNT; a solenoid current slant control was employed to respond to electronically controlled A/T; and noise and vibration shift feeling instrumentation can also be used on option. Number of supply is four sets of front engine/front wheel drive (FF) car A/T testers for overseas countries, and two sets of FF A/T tests for use in Japan. (NEDO)

  19. Phase 1 space fission propulsion system testing and development progress

    International Nuclear Information System (INIS)

    Van Dyke, Melissa; Houts, Mike; Godfroy, Tom; Dickens, Ricky; Poston, David; Kapernick, Rick; Reid, Bob; Salvail, Pat; Ring, Peter

    2002-01-01

    Successful development of space fission systems requires an extensive program of affordable and realistic testing. In addition to tests related to design/development of the fission system, realistic testing of the actual flight unit must also be performed. If the system is designed to operate within established radiation damage and fuel burn up limits while simultaneously being designed to allow close simulation of heat from fission using resistance heaters, high confidence in fission system performance and lifetime can be attained through a series of non-nuclear tests. The Safe Affordable Fission Engine (SAFE) test series, whose ultimate goal is the demonstration of a 300 kW flight configuration system, has demonstrated that realistic testing can be performed using non-nuclear methods. This test series, carried out in collaboration with other NASA centers, other government agencies, industry, and universities, successfully completed a testing program with a 30 kWt core. Stirling engine, and ion engine configuration. Additionally, a 100 kWt core is in fabrication and appropriate test facilities are being reconfigured. This paper describes the current SAFE non-nuclear tests, which includes test article descriptions, test results and conclusions, and future test plans

  20. Preliminary analysis of accident in SST-1 current feeder system

    International Nuclear Information System (INIS)

    Roy, Swati; Kanabar, Deven; Garg, Atul; Singh, Amit; Tanna, Vipul; Prasad, Upendra; Srinivasan, R.

    2017-01-01

    Steady-state Tokamak-1 (SST-1) has 16 superconducting Toroidal field (TF) and 9 superconducting poloidal field (PF) coils rated for 10kA DC. All the TF are connected in series and are operated in DC condition whereas PF coils are individually operated in pulse mode during SST-1 campaigns. SST-1 current feeder system (CFS) houses 9 pairs of PF current leads and 1 pair of TF current leads. During past SST-1 campaign, there were arcing incidents within SST-1 CFS chamber which caused significant damage to PF superconducting current leads as well as its Helium cooling lines of the current leads. This paper brings out the preliminary analysis of the mentioned arcing incident, possible reasons and its investigation thereby laying out the sequence of events. From this analysis and observations, various measures to avoid such arcing incidents have also been proposed. (author)

  1. Scheduling system for test automation framework

    NARCIS (Netherlands)

    Wahyudi, Djohan

    2014-01-01

    An Interventional X-ray (iXR) system provides real time X-ray imaging with high image clarity and low X-ray dose. After several years of development, the iXR System has become complex. In order to verify the correct operation of the system, the system integration and test group performs extensive

  2. Systemic Immunotherapy for Urothelial Cancer: Current Trends and Future Directions

    Directory of Open Access Journals (Sweden)

    Shilpa Gupta

    2017-01-01

    Full Text Available Urothelial cancer of the bladder, renal pelvis, ureter, and other urinary organs is the fifth most common cancer in the United States, and systemic platinum-based chemotherapy remains the standard of care for first-line treatment of advanced/metastatic urothelial carcinoma (UC. Until recently, there were very limited options for patients who are refractory to chemotherapy, or do not tolerate chemotherapy due to toxicities and overall outcomes have remained very poor. While the role of immunotherapy was first established in non-muscle invasive bladder cancer in the 1970s, no systemic immunotherapy was approved for advanced disease until the recent approval of a programmed death ligand-1 (PD-L1 inhibitor, atezolizumab, in patients with advanced/metastatic UC who have progressed on platinum-containing regimens. This represents a significant milestone in this disease after a void of over 30 years. In addition to atezolizumab, a variety of checkpoint inhibitors have shown a significant activity in advanced/metastatic urothelial carcinoma and are expected to gain Food and Drug Administration (FDA approval in the near future. The introduction of novel immunotherapy agents has led to rapid changes in the field of urothelial carcinoma. Numerous checkpoint inhibitors are being tested alone or in combination in the first and subsequent-line therapies of metastatic disease, as well as neoadjuvant and adjuvant settings. They are also being studied in combination with radiation therapy and for non-muscle invasive bladder cancer refractory to BCG. Furthermore, immunotherapy is being utilized for those ineligible for firstline platinum-based chemotherapy. This review outlines the novel immunotherapy agents which have either been approved, or are currently being investigated in clinical trials in UC.

  3. Giant Magnetoresistance Sensors: A Review on Structures and Non-Destructive Eddy Current Testing Applications

    Directory of Open Access Journals (Sweden)

    Damhuji Rifai

    2016-02-01

    Full Text Available Non-destructive eddy current testing (ECT is widely used to examine structural defects in ferromagnetic pipe in the oil and gas industry. Implementation of giant magnetoresistance (GMR sensors as magnetic field sensors to detect the changes of magnetic field continuity have increased the sensitivity of eddy current techniques in detecting the material defect profile. However, not many researchers have described in detail the structure and issues of GMR sensors and their application in eddy current techniques for nondestructive testing. This paper will describe the implementation of GMR sensors in non-destructive testing eddy current testing. The first part of this paper will describe the structure and principles of GMR sensors. The second part outlines the principles and types of eddy current testing probe that have been studied and developed by previous researchers. The influence of various parameters on the GMR measurement and a factor affecting in eddy current testing will be described in detail in the third part of this paper. Finally, this paper will discuss the limitations of coil probe and compensation techniques that researchers have applied in eddy current testing probes. A comprehensive review of previous studies on the application of GMR sensors in non-destructive eddy current testing also be given at the end of this paper.

  4. Giant Magnetoresistance Sensors: A Review on Structures and Non-Destructive Eddy Current Testing Applications

    Science.gov (United States)

    Rifai, Damhuji; Abdalla, Ahmed N.; Ali, Kharudin; Razali, Ramdan

    2016-01-01

    Non-destructive eddy current testing (ECT) is widely used to examine structural defects in ferromagnetic pipe in the oil and gas industry. Implementation of giant magnetoresistance (GMR) sensors as magnetic field sensors to detect the changes of magnetic field continuity have increased the sensitivity of eddy current techniques in detecting the material defect profile. However, not many researchers have described in detail the structure and issues of GMR sensors and their application in eddy current techniques for nondestructive testing. This paper will describe the implementation of GMR sensors in non-destructive testing eddy current testing. The first part of this paper will describe the structure and principles of GMR sensors. The second part outlines the principles and types of eddy current testing probe that have been studied and developed by previous researchers. The influence of various parameters on the GMR measurement and a factor affecting in eddy current testing will be described in detail in the third part of this paper. Finally, this paper will discuss the limitations of coil probe and compensation techniques that researchers have applied in eddy current testing probes. A comprehensive review of previous studies on the application of GMR sensors in non-destructive eddy current testing also be given at the end of this paper. PMID:26927123

  5. Nonequilibrium Microscopic Distribution of Thermal Current in Particle Systems

    KAUST Repository

    Yukawa, Satoshi

    2009-02-15

    A nonequilibrium distribution function of microscopic thermal current is studied by a direct numerical simulation in a thermal conducting steady state of particle systems. Two characteristic temperatures of the thermal current are investigated on the basis of the distribution. It is confirmed that the temperature depends on the current direction; Parallel temperature to the heat-flux is higher than antiparallel one. The difference between the parallel temperature and the antiparallel one is proportional to a macroscopic temperature gradient. ©2009 The Physical Society of Japan.

  6. Nonequilibrium Microscopic Distribution of Thermal Current in Particle Systems

    KAUST Repository

    Yukawa, Satoshi; Shimada, Takashi; Ogushi, Fumiko; Ito, Nobuyasu

    2009-01-01

    A nonequilibrium distribution function of microscopic thermal current is studied by a direct numerical simulation in a thermal conducting steady state of particle systems. Two characteristic temperatures of the thermal current are investigated on the basis of the distribution. It is confirmed that the temperature depends on the current direction; Parallel temperature to the heat-flux is higher than antiparallel one. The difference between the parallel temperature and the antiparallel one is proportional to a macroscopic temperature gradient. ©2009 The Physical Society of Japan.

  7. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    Energy Technology Data Exchange (ETDEWEB)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein [Center of Excellence for Power System Automation and Operation, Electrical Engineering Department, Iran University of Science and Technology (IUST), Tehran (Iran, Islamic Republic of)], E-mail: heydari@iust.ac.ir, E-mail: faramarz_faghihi@ee.iust.ac.ir, E-mail: reza_sharifi@ee.iust.ac.ir, E-mail: amirhosseinp@ee.iust.ac.ir

    2008-09-15

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  8. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    Science.gov (United States)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-09-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT.

  9. Superconducting technology for overcurrent limiting in a 25 kA current injection system

    International Nuclear Information System (INIS)

    Heydari, Hossein; Faghihi, Faramarz; Sharifi, Reza; Poursoltanmohammadi, Amir Hossein

    2008-01-01

    Current injection transformer (CIT) systems are within the major group of the standard type test of high current equipment in the electrical industry, so their performance becomes very important. When designing high current systems, there are many factors to be considered from which their overcurrent protection must be ensured. The output of a CIT is wholly dependent on the impedance of the equipment under test (EUT). Therefore current flow beyond the allowable limit can occur. The present state of the art provides an important guide to developing current limiters not only for the grid application but also in industrial equipment. This paper reports the state of the art in the technology available that could be developed into an application of superconductivity for high current equipment (CIT) protection with no test disruption. This will result in a greater market choice and lower costs for equipment protection solutions, reduced costs and improved system reliability. The paper will also push the state of the art by using two distinctive circuits, closed-core and open-core, for overcurrent protection of a 25 kA CIT system, based on a flux-lock-type superconducting fault current limiter (SFCL) and magnetic properties of high temperature superconducting (HTS) elements. An appropriate location of the HTS element will enhance the rate of limitation with the help of the magnetic field generated by the CIT output busbars. The calculation of the HTS parameters for overcurrent limiting is also performed to suit the required current levels of the CIT

  10. Output Current Ripple Reduction Algorithms for Home Energy Storage Systems

    Directory of Open Access Journals (Sweden)

    Jin-Hyuk Park

    2013-10-01

    Full Text Available This paper proposes an output current ripple reduction algorithm using a proportional-integral (PI controller for an energy storage system (ESS. In single-phase systems, the DC/AC inverter has a second-order harmonic at twice the grid frequency of a DC-link voltage caused by pulsation of the DC-link voltage. The output current of a DC/DC converter has a ripple component because of the ripple of the DC-link voltage. The second-order harmonic adversely affects the battery lifetime. The proposed algorithm has an advantage of reducing the second-order harmonic of the output current in the variable frequency system. The proposed algorithm is verified from the PSIM simulation and experiment with the 3 kW ESS model.

  11. The jet 10-MW lower hybrid current drive system

    International Nuclear Information System (INIS)

    Gormezano, C.; Bosia, G.; Brinkschulte, H.; David, C.; Dobbing, J.A.; Kaye, A.S.; Jacquinot, J.; Lloyd, B.; Knowlton, S.; Moreau, D.

    1987-01-01

    A Lower Hybrid system to control the plasma current profile is being prepared so that a higher central electron temperature can be obtained. The proposed system is designed to launch 10 MW of power at f = 3.7 GHz through a single port in JET, producing between 1 and 2 MA of RF driven current at an average density of 5 x 10 19 m -3 . Current drive efficiency is maximized by using a low value of the parallel wave number spectrum (N// - 1.3 - 2.3). The final launcher will be made of 48 multijunctions fed by 24 klystrons with the proper phasing. Dynamic matching of the launcher will be optimized by moving the launcher in real time during the pulse. A first stage (2 MW) is presently under construction. The full system is being designed to be in operation in 1990

  12. EIA systems in Nigeria: evolution, current practice and shortcomings

    International Nuclear Information System (INIS)

    Ogunba, Olusegun A.

    2004-01-01

    Amidst mounting criticism of Environmental Impact Assessments (EIAs) carried out in Nigeria under the three independent EIA systems--the EIA Decree 86 (1992), the Town and Country Planning Decree 88 (1992) and the Petroleum Act (1969)--the paper traces the evolution of Nigeria's systems and appraises current practice and shortcomings. The path of development of the systems was traced within the framework of Gibson's model of EIA evolution [Impact Assess. Proj. Apprais., 20 (3) 2002, 151-159], while current practice and shortcomings were explored in random interview surveys of consultant firms, approval authorities and the academia. It was seen that Gibson's four-stage model is not exactly representative of the Nigerian situation, and a more appropriate six-stage model was developed. It was also established that the current practices of the three EIA systems were at different stages of evolution: one of the EIA schemes (the Town and Country Planning Decree) has not evolved satisfactorily, while the other two EIA systems have produced intricate legislations and guidelines, but fall short of first-rate practice. The other discovery was that the simultaneous use of three independent systems creates unnecessary duplication of EIA preparation with considerable time and money costs. The paper advises that Nigeria can make substantial progress along the evolutionary path through a correction of observed system shortcomings and a merger of the three systems

  13. Cascade Distiller System Performance Testing Interim Results

    Science.gov (United States)

    Callahan, Michael R.; Pensinger, Stuart; Sargusingh, Miriam J.

    2014-01-01

    The Cascade Distillation System (CDS) is a rotary distillation system with potential for greater reliability and lower energy costs than existing distillation systems. Based upon the results of the 2009 distillation comparison test (DCT) and recommendations of the expert panel, the Advanced Exploration Systems (AES) Water Recovery Project (WRP) project advanced the technology by increasing reliability of the system through redesign of bearing assemblies and improved rotor dynamics. In addition, the project improved the CDS power efficiency by optimizing the thermoelectric heat pump (TeHP) and heat exchanger design. Testing at the NASA-JSC Advanced Exploration System Water Laboratory (AES Water Lab) using a prototype Cascade Distillation Subsystem (CDS) wastewater processor (Honeywell d International, Torrance, Calif.) with test support equipment and control system developed by Johnson Space Center was performed to evaluate performance of the system with the upgrades as compared to previous system performance. The system was challenged with Solution 1 from the NASA Exploration Life Support (ELS) distillation comparison testing performed in 2009. Solution 1 consisted of a mixed stream containing human-generated urine and humidity condensate. A secondary objective of this testing is to evaluate the performance of the CDS as compared to the state of the art Distillation Assembly (DA) used in the ISS Urine Processor Assembly (UPA). This was done by challenging the system with ISS analog waste streams. This paper details the results of the AES WRP CDS performance testing.

  14. Automatic test system of the photomultipliers

    International Nuclear Information System (INIS)

    Shiino, Kazuo; Kono, Koji; Ishii, Takanobu; Kasai, Seiji; Yamada, Sakue; Kitamura, Shoichi.

    1990-03-01

    A test system of R580 photomultipliers (PMTs) was constructed for the ZEUS experiment HERA. In this report, we will describe the general feature of the test system, each component of the setup, the procedure of the measurements, the data analyses and the results of the first 800 PMT measurements. (author)

  15. Test procedure for boxed waste assay system

    International Nuclear Information System (INIS)

    Wachter, J.

    1994-01-01

    This document, prepared by Los Alamos National Laboratory's NMT-4 group, details the test methodology and requirements for Acceptance/Qualification testing of a Boxed Waste Assay System (BWAS) designed and constructed by Pajarito Scientific Corporation. Testing of the BWAS at the Plutonium Facility (TA55) at Los Alamos National Laboratory will be performed to ascertain system adherence to procurement specification requirements. The test program shall include demonstration of conveyor handling capabilities, gamma ray energy analysis, and imaging passive/active neutron accuracy and sensitivity. Integral to these functions is the system's embedded operating and data reduction software

  16. BMFT-UPTF densitometer system test report

    International Nuclear Information System (INIS)

    Menkhaus, D.E.

    1985-11-01

    This report documents acceptance test results performed on the five Upper Plenum Test Facility (UPTF) three-beam densitometer systems and spare parts. The five densitometer systems are used on the UPTF four hot legs and broken cold leg to measure average chordal-beam densities. The primary objectives of the tests performed were: to verify all assemblies fit as designed (mechanical fitup); to ensure radiation levels met the criteria (<2.5 mR/h); to verify that design accuracy requirements were met (performance tests); and to verify proper operation of the densitometer systems (functional checks). 15 figs., 11 tabs

  17. Testing Real-Time Systems Using UPPAAL

    DEFF Research Database (Denmark)

    Hessel, Anders; Larsen, Kim Guldstrand; Mikucionis, Marius

    2008-01-01

    This chapter presents principles and techniques for model-based black-box conformance testing of real-time systems using the Uppaal model-checking tool-suite. The basis for testing is given as a network of concurrent timed automata specified by the test engineer. Relativized input...

  18. Unit Testing for Command and Control Systems

    Science.gov (United States)

    Alexander, Joshua

    2018-01-01

    Unit tests were created to evaluate the functionality of a Data Generation and Publication tool for a command and control system. These unit tests are developed to constantly evaluate the tool and ensure it functions properly as the command and control system grows in size and scope. Unit tests are a crucial part of testing any software project and are especially instrumental in the development of a command and control system. They save resources, time and costs associated with testing, and catch issues before they become increasingly difficult and costly. The unit tests produced for the Data Generation and Publication tool to be used in a command and control system assure the users and stakeholders of its functionality and offer assurances which are vital in the launching of spacecraft safely.

  19. Preoperational test report, primary ventilation condensate system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-01-29

    Preoperational test report for Primary Ventilation Condensate System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides a collection point for condensate generated by the W-030 primary vent offgas cooling system serving tanks AYIOI, AY102, AZIOI, AZI02. The system is located inside a shielded ventilation equipment cell and consists of a condensate seal pot, sampling features, a drain line to existing Catch Tank 241-AZ-151, and a cell sump jet pump. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  20. Energy Current Cumulants in One-Dimensional Systems in Equilibrium

    Science.gov (United States)

    Dhar, Abhishek; Saito, Keiji; Roy, Anjan

    2018-06-01

    A recent theory based on fluctuating hydrodynamics predicts that one-dimensional interacting systems with particle, momentum, and energy conservation exhibit anomalous transport that falls into two main universality classes. The classification is based on behavior of equilibrium dynamical correlations of the conserved quantities. One class is characterized by sound modes with Kardar-Parisi-Zhang scaling, while the second class has diffusive sound modes. The heat mode follows Lévy statistics, with different exponents for the two classes. Here we consider heat current fluctuations in two specific systems, which are expected to be in the above two universality classes, namely, a hard particle gas with Hamiltonian dynamics and a harmonic chain with momentum conserving stochastic dynamics. Numerical simulations show completely different system-size dependence of current cumulants in these two systems. We explain this numerical observation using a phenomenological model of Lévy walkers with inputs from fluctuating hydrodynamics. This consistently explains the system-size dependence of heat current fluctuations. For the latter system, we derive the cumulant-generating function from a more microscopic theory, which also gives the same system-size dependence of cumulants.

  1. Water electrolysis system refurbishment and testing

    Science.gov (United States)

    Greenough, B. M.

    1972-01-01

    The electrolytic oxygen generator for the back-up water electrolysis system in a 90-day manned test was refurbished, improved and subjected to a 182-day bench test. The performance of the system during the test demonstrated the soundness of the basic electrolysis concept, the high development status of the automatic controls which allowed completely hands-off operation, and the capability for orbital operation. Some design improvements are indicated.

  2. PFN tool test and calibration system

    International Nuclear Information System (INIS)

    Stephenson, W.A.

    1981-12-01

    A system has been developed for the functional testing and neutron output calibration of the PFN (Prompt Fission Neutron) Uranium Logging Tool. The system was designed primarily for field work and consists of a special vehicle as well as test apparatus. Only the pertinent instrumentation is described. This document will serve as an Instruction and Test Equipment service manual for those involved with calibration of the neutron output of the PFN tool

  3. PETA: Methodology of Information Systems Security Penetration Testing

    Directory of Open Access Journals (Sweden)

    Tomáš Klíma

    2016-12-01

    Full Text Available Current methodologies of information systems penetration testing focuses mainly on a high level and technical description of the testing process. Unfortunately, there is no methodology focused primarily on the management of these tests. It often results in a situation when the tests are badly planned, managed and the vulnerabilities found are unsystematically remediated. The goal of this article is to present new methodology called PETA which is focused mainly on the management of penetration tests. Development of this methodology was based on the comparative analysis of current methodologies. New methodology incorporates current best practices of IT governance and project management represented by COBIT and PRINCE2 principles. Presented methodology has been quantitatively evaluated.

  4. Coliform Bacteria Monitoring in Fish Systems: Current Practices in Public Aquaria.

    Science.gov (United States)

    Culpepper, Erin E; Clayton, Leigh A; Hadfield, Catherine A; Arnold, Jill E; Bourbon, Holly M

    2016-06-01

    Public aquaria evaluate coliform indicator bacteria levels in fish systems, but the purpose of testing, testing methods, and management responses are not standardized, unlike with the coliform bacteria testing for marine mammal enclosures required by the U.S. Department of Agriculture. An online survey was sent to selected aquaria to document current testing and management practices in fish systems without marine mammals. The information collected included indicator bacteria species, the size and type of systems monitored, the primary purpose of testing, sampling frequency, test methods, the criteria for interpreting results, corrective actions, and management changes to limit human exposure. Of the 25 institutions to which surveys were sent, 19 (76%) responded. Fourteen reported testing for fecal indicator bacteria in fish systems. The most commonly tested indicator species were total (86%) and fecal (79%) coliform bacteria, which were detected by means of the membrane filtration method (64%). Multiple types and sizes of systems were tested, and the guidelines for testing and corrective actions were highly variable. Only three institutions performed additional tests to confirm the identification of indicator organisms. The results from this study can be used to compare bacterial monitoring practices and protocols in fish systems, as an aid to discussions relating to the accuracy and reliability of test results, and to help implement appropriate management responses. Received August 23, 2015; accepted December 29, 2015.

  5. Space Telecommunications Radio System (STRS) Compliance Testing

    Science.gov (United States)

    Handler, Louis M.

    2011-01-01

    The Space Telecommunications Radio System (STRS) defines an open architecture for software defined radios. This document describes the testing methodology to aid in determining the degree of compliance to the STRS architecture. Non-compliances are reported to the software and hardware developers as well as the NASA project manager so that any non-compliances may be fixed or waivers issued. Since the software developers may be divided into those that provide the operating environment including the operating system and STRS infrastructure (OE) and those that supply the waveform applications, the tests are divided accordingly. The static tests are also divided by the availability of an automated tool that determines whether the source code and configuration files contain the appropriate items. Thus, there are six separate step-by-step test procedures described as well as the corresponding requirements that they test. The six types of STRS compliance tests are: STRS application automated testing, STRS infrastructure automated testing, STRS infrastructure testing by compiling WFCCN with the infrastructure, STRS configuration file testing, STRS application manual code testing, and STRS infrastructure manual code testing. Examples of the input and output of the scripts are shown in the appendices as well as more specific information about what to configure and test in WFCCN for non-compliance. In addition, each STRS requirement is listed and the type of testing briefly described. Attached is also a set of guidelines on what to look for in addition to the requirements to aid in the document review process.

  6. A Neuron Model Based Ultralow Current Sensor System for Bioapplications

    Directory of Open Access Journals (Sweden)

    A. K. M. Arifuzzman

    2016-01-01

    Full Text Available An ultralow current sensor system based on the Izhikevich neuron model is presented in this paper. The Izhikevich neuron model has been used for its superior computational efficiency and greater biological plausibility over other well-known neuron spiking models. Of the many biological neuron spiking features, regular spiking, chattering, and neostriatal spiny projection spiking have been reproduced by adjusting the parameters associated with the model at hand. This paper also presents a modified interpretation of the regular spiking feature in which the firing pattern is similar to that of the regular spiking but with improved dynamic range offering. The sensor current ranges between 2 pA and 8 nA and exhibits linearity in the range of 0.9665 to 0.9989 for different spiking features. The efficacy of the sensor system in detecting low amount of current along with its high linearity attribute makes it very suitable for biomedical applications.

  7. A partial Hamiltonian approach for current value Hamiltonian systems

    Science.gov (United States)

    Naz, R.; Mahomed, F. M.; Chaudhry, Azam

    2014-10-01

    We develop a partial Hamiltonian framework to obtain reductions and closed-form solutions via first integrals of current value Hamiltonian systems of ordinary differential equations (ODEs). The approach is algorithmic and applies to many state and costate variables of the current value Hamiltonian. However, we apply the method to models with one control, one state and one costate variable to illustrate its effectiveness. The current value Hamiltonian systems arise in economic growth theory and other economic models. We explain our approach with the help of a simple illustrative example and then apply it to two widely used economic growth models: the Ramsey model with a constant relative risk aversion (CRRA) utility function and Cobb Douglas technology and a one-sector AK model of endogenous growth are considered. We show that our newly developed systematic approach can be used to deduce results given in the literature and also to find new solutions.

  8. High beam current shut-off systems in the APS linac and low energy transfer line

    International Nuclear Information System (INIS)

    Wang, X.; Knott, M.; Lumpkin, A.

    1994-01-01

    Two independent high beam current shut-off current monitoring systems (BESOCM) have been installed in the APS linac and the low energy transport line to provide personnel safety protection in the event of acceleration of excessive beam currents. Beam current is monitored by a fast current transformer (FCT) and fully redundant supervisory circuits connected to the Access Control Interlock System (ACIS) for beam intensity related shutdowns of the linac. One FCT is located at the end of the positron linac and the other in the low energy transport line, which directs beam to the positron accumulator ring (PAR). To ensure a high degree of reliability, both systems employ a continuous self-checking function, which injects a test pulse to a single-turn test winding after each ''real'' beam pulse to verify that the system is fully functional. The system is designed to be fail-safe for all possible system faults, such as loss of power, open or shorted signal or test cables, loss of external trigger, malfunction of gated integrator, etc. The system has been successfully commissioned and is now a reliable part of the total ACIS

  9. Current Strategic Business Plan for the Implementation of Digital Systems.

    Science.gov (United States)

    Library of Congress, Washington, DC. National Library Service for the Blind and Physically Handicapped.

    This document presents a current strategic business plan for the implementation of digital systems and services for the free national library program operated by the National Library Service for the Blind and Physically Handicapped, Library of Congress, its network of cooperating regional and local libraries, and the United States Postal Service.…

  10. LLNL current meter array--concept and system description

    Energy Technology Data Exchange (ETDEWEB)

    Mantrom, D.D. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    A measurement capability using a horizontal array of 10 S4 current meters mounted on a stiff floating structure with 35 m aperture has been developed to support interpretation of radar imaging of surface effects associated with internal waves. This system has been fielded three times and most recently, has collected data alongside the sea-surface footprint of a land-fixed radar imaging ship-generated internal waves. The underlying need for this measurement capability is described. The specifications resulting from this need are presented and the engineering design and deployment procedures of the platform and systems that resulted are described The current meter data are multiplexed along with meteorological and system status data on board the floating platform and are telemetered to a shore station and on to a data acquisition system. The raw data are recorded, and are then processed to form space-time images of current and strain rate (a spatial derivative of the current field). Examples of raw and processed data associated with ship-generated internal waves are presented.

  11. Velocity of small-scale auroral ionospheric current systems over ...

    Indian Academy of Sciences (India)

    At the latter times, triangulation with 3 uxgate magnetometers located at the vertices of a suitable triangle provides a means of monitoring mobile auroral ionospheric current systems over Maitri. The spacing between the magnetometers is typically kept at 75-200 km, keeping in mind the scale-sizes of ∼100 km for these ...

  12. Research on Current Trends and Developments in Library Automation Systems.

    Science.gov (United States)

    Clyde, Laurel A.

    A research project was undertaken in 1992 in order to identify, describe, and analyze current trends and developments in library automation systems and library software. The starting point is work conducted in 1988/1989 that formed the foundation of the book "Computer Software for School Libraries: A Directory." A 1992 survey of software…

  13. Study on pulsed current cathodic protection in a simulated system

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Milin; Li, Helin [Xi' an Jiao Tong Universitiy (China)]|[Tubular Goods Research Center of China National Petroleum Corp. (China); Qiu, Yubing; Guo, Xingpeng [Hua Zhong University of Science and Techonology (China)

    2004-07-01

    The pulsed current cathodic protection (PCCP) is a new cathodic protection (CP) technology and shows more advantages over the conventional DC cathodic protection (DCCP) in oil well casing system. However, little information about PCCP is reported. In this research, a simulated CP system was set up in a pool of 3.5 m x 2.0 m x 3.0 m size, in which the effects of the square wave pulsed current (SWPC) parameters (amplitude: IA, frequency: f, duty cycle: P), auxiliary anode distance (d) and media conductivity ({mu}) on the cathodic potential (E) distribution were studied, and the protection effects of PCCP and DCCP were compared. The results show that with increase of the square wave parameters (IA, f, P), the E distribution becomes more negative and the effects of each current parameter are relate closely to the cathode polarizing state. Only with suitable square wave parameters can the whole cathode be effectively protected. With increase of d and {mu}, the E distribution becomes more uniform. Compared with DCCP system, PCCP system has much more uniform E distribution, costs less average current, and gains much better protection effects. Further, the mechanism of PCCP was analyzed. (authors)

  14. Preoperational test report, recirculation ventilation systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  15. Preoperational test report, recirculation ventilation systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-11

    This represents a preoperational test report for Recirculation Ventilation Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system provides vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102 and supports the ability to exhaust air from each tank. Each system consists of a valved piping loop, a fan, condenser, and moisture separator; equipment is located inside each respective tank farm in its own hardened building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  16. Test results of the 18 kA EDIPO HTS current leads

    International Nuclear Information System (INIS)

    Wesche, Rainer; Bagnasco, Maurizio; Bruzzone, Pierluigi; Felder, Roland; Guetg, Marc; Holenstein, Manuel; Jenni, Markus; March, Stephen; Roth, Felix; Vogel, Martin

    2011-01-01

    For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

  17. Test results of the 18 kA EDIPO HTS current leads

    Energy Technology Data Exchange (ETDEWEB)

    Wesche, Rainer, E-mail: rainer.wesche@psi.ch [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland); Bagnasco, Maurizio; Bruzzone, Pierluigi; Felder, Roland; Guetg, Marc; Holenstein, Manuel; Jenni, Markus; March, Stephen; Roth, Felix; Vogel, Martin [Ecole Polytechnique Federale de Lausanne (EPFL), Centre de Recherches en Physique des Plasmas (CRPP), Association Euratom - Confederation Suisse, 5232 Villigen PSI (Switzerland)

    2011-10-15

    For the new test facility EDIPO (European DIPOle), to be hosted by CRPP, two 18 kA HTS current leads were manufactured and successfully tested. The HTS module, made of AgMgAu/Bi-2223 tapes, is cooled only by heat conduction to the cold end, while the copper part is cooled by forced flow helium gas. The current leads were tested at low voltage up to the maximum current of 18 kA. The helium mass flow rates required for stable operation at various currents were determined. In addition to the steady state operation, the transient behavior in the case of a loss of flow was studied experimentally. The test results provide an estimate of the operational limits of the EDIPO HTS current leads.

  18. Adaptation of eddy current methods to the multiple problems of reactor testing

    International Nuclear Information System (INIS)

    Stumm, W.

    1975-01-01

    In reactor testing, the eddy current method is mainly used for the testing of surface regions inside the pressure vessel, on welds and joints, and for the testing of thin-walled pipes, e.g. the heat exchanger pipes. (RW/AK) [de

  19. Eddy Current, Magnetic Particle and Hardness Testing, Aviation Quality Control (Advanced): 9227.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This unit of instruction includes the principles of eddy current, magnetic particle and hardness testing; standards used for analyzing test results; techniques of operating equipment; interpretation of indications; advantages and limitations of these methods of testing; care and calibration of equipment; and safety and work precautions. Motion…

  20. The International English Language Testing System (IELTS): The Speaking Test.

    Science.gov (United States)

    Ingram, D. E.

    1991-01-01

    The International English Language Testing System (IELTS) assesses proficiency in English both generally and for special purposes of non-native English speakers studying, training, or learning English in English-speaking countries. The Speaking subtest of the IELTS measures a candidate's general proficiency in speaking in everyday situations via a…

  1. Seismic fragility test of a 6-inch diameter pipe system

    International Nuclear Information System (INIS)

    Chen, W.P.; Onesto, A.T.; DeVita, V.

    1987-02-01

    This report contains the test results and assessments of seismic fragility tests performed on a 6-inch diameter piping system. The test was funded by the US Nuclear Regulatory Commission (NRC) and conducted by ETEC. The objective of the test was to investigate the ability of a representative nuclear piping system to withstand high level dynamic seismic and other loadings. Levels of loadings achieved during seismic testing were 20 to 30 times larger than normal elastic design evaluations to ASME Level D limits would permit. Based on failure data obtained during seismic and other dynamic testing, it was concluded that nuclear piping systems are inherently able to withstand much larger dynamic seismic loadings than permitted by current design practice criteria or predicted by the probabilistic risk assessment (PRA) methods and several proposed nonlinear methods of failure analysis

  2. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-05-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  3. Electrical performance characteristics of the SSC Accelerator System String Test

    International Nuclear Information System (INIS)

    Robinson, W.; Burgett, W.; Dombeck, T.; Gannon, J.; Kraushaar, P.; McInturff, A.; Savord, T.; Tool, G.

    1993-01-01

    The string test facility was constructed to provide a development test bed for the arc regions of the Superconducting Super Collider (SSC). Significant effort has been devoted to the development and testing of superconducting magnets, spools, and accelerator control systems required for the SSC. The string test facility provides the necessary environment required to evaluate the operational performance of these components as they are configured as an accelerator lens in the collider. This discussion will review the results of high current testing of the string conducted to evaluate magnet element uniformity and compatibility, the splice resistance used to connect the magnets, and system response to various quench conditions. Performance results of the spools, energy bypass systems, energy dump, and the power supply system are also discussed

  4. SIMS Prototype System 4: performance test report

    Energy Technology Data Exchange (ETDEWEB)

    1978-10-09

    The results obtained during testing of a self-contained, preassembled air type solar system, designed for installation remote from the dwelling, to provide space heating and hot water are presented. Data analysis is included which documents the system performance and verifies the suitability of SIMS Prototype System 4 for field installation.

  5. Internal testing of pipe systems with IRIS inspection system

    International Nuclear Information System (INIS)

    1986-01-01

    The internal piping inspection system IRIS allows inside testing of pipes with an internal diameter of NW 70 as a minimum, and of any horizontal or vertical layout of the piping system. Visual testing is done by means of an integrated CCD video system with high resolution power. Technical data are given and examples of applications, in the German and English language. (DG) [de

  6. Data Link Test and Analysis System/ATCRBS Transponder Test System Technical Reference

    Science.gov (United States)

    1990-05-01

    This document references material for personnel using or making software changes : to the Data Link Test and Analysis System (DATAS) for Air Traffic Control Radar : Beacon System (ATCRBS) transponder testing and data collection. This is one of : a se...

  7. PUREX exhaust ventilation system installation test report

    International Nuclear Information System (INIS)

    Blackaby, W.B.

    1997-01-01

    This Acceptance Test Report validates the testing performed, the exceptions logged and resolved and certifies this portion of the SAMCONS has met all design and test criteria to perform as an operational system. The proper installation of the PUREX exhaust ventilation system components and wiring was systematically evaluated by performance of this procedure. Proper operation of PUREX exhaust fan inlet, outlet, and vortex damper actuators and limit switches were verified, using special test equipment, to be correct and installed wiring connections were verified by operation of this equipment

  8. Model-based testing for embedded systems

    CERN Document Server

    Zander, Justyna; Mosterman, Pieter J

    2011-01-01

    What the experts have to say about Model-Based Testing for Embedded Systems: "This book is exactly what is needed at the exact right time in this fast-growing area. From its beginnings over 10 years ago of deriving tests from UML statecharts, model-based testing has matured into a topic with both breadth and depth. Testing embedded systems is a natural application of MBT, and this book hits the nail exactly on the head. Numerous topics are presented clearly, thoroughly, and concisely in this cutting-edge book. The authors are world-class leading experts in this area and teach us well-used

  9. Current Monitoring System for ITER Like ICRH Antenna

    International Nuclear Information System (INIS)

    Argouarch, A.

    2006-01-01

    On TS antennas, the power transfer optimization from ICRH antenna to Plasma load is performed using feedback internal matching system. Experimental handling is required to mach the reactive impedance accordingly to the fluctuant plasma loading. As part of the development of the new ICRH prototype antenna, an additional measurement system based on Rogowski coils was developed to monitor the current distribution in antenna straps. The objective is to control module and phase of the antenna current straps with measurement provided by the coil system. Matching capacitors values, generators power and phase can also be controlled using the output of the devices, improving the real time matching control of the array. This paper details the new measurement layout, the Rogowski coil, and the whole system connected on each strap design for RF currents measurement between 40 MHz - 60 MHz for maximum amplitude of 1 kA. On the new ICRH prototype antenna, the measurement coils are coupled to the point where the strap currents are short circuited to the frame. The module and phase measurements are performed with the coils by direct magnetic induction in a vacuum and high temperature environment. Also, the Rogowski coils were characterized at low level power with vector network analyzer and the design adapted in order to obtain a controlled and reproducible gain in the desire bandwidth. The transconductive function is established with an experimental gain near -80 dB between primary circuit and inductive signal generated by the Rogowski coil. In a second step, the system with its associated electronic was qualified under high RF power. First results with high RF current (closed to 500 A at 57 MHz) match the desire Rogowski coil response. Compromises with electrical response at low power level and the coil under thermal/RF stresses were the most challenging part of the development. The overall response of the system and the current module/phase measurements are promising. A proper

  10. Test results of six-month test of two water electrolysis systems

    Science.gov (United States)

    Mills, E. S.; Wells, G. W.

    1972-01-01

    The two water electrolysis systems used in the NASA space station simulation 90-day manned test of a regenerative life support system were refurbished as required and subjected to 26-weeks of testing. The two electrolysis units are both promising systems for oxygen and hydrogen generation and both needed extensive long-term testing to evaluate the performance of the respective cell design and provide guidance for further development. Testing was conducted to evaluate performance in terms of current, pressure, variable oxygen demands, and orbital simulation. An automatic monitoring system was used to record, monitor and printout performance data at one minute, ten minute or one-hour intervals. Performance data is presented for each day of system operation for each module used during the day. Failures are analyzed, remedial action taken to eliminate problems is discussed and recommendations for redesign for future space applications are stated.

  11. Survey of Digital Feedback Systems in High Current Storage Rings

    International Nuclear Information System (INIS)

    Teytelman, Dmitry

    2003-01-01

    In the last decade demand for brightness in synchrotron light sources and luminosity in circular colliders led to construction of multiple high current storage rings. Many of these new machines require feedback systems to achieve design stored beam currents. In the same time frame the rapid advances in the technology of digital signal processing allowed the implementation of these complex feedback systems. In this paper I concentrate on three applications of feedback to storage rings: orbit control in light sources, coupled-bunch instability control, and low-level RF control. Each of these applications is challenging in areas of processing bandwidth, algorithm complexity, and control of time-varying beam and system dynamics. I will review existing implementations as well as comment on promising future directions

  12. Experience of superconducting current feeders system of SST-1

    International Nuclear Information System (INIS)

    Gupta, N.C.; Garg, A.; Sonara, D.

    2014-01-01

    The superconducting current feeder system for SST-1 which has been installed and commissioned recently along with SST-1, felicitates to energize the SST-1. The CFS consists of ten pairs of 10,000 Ampere (A) rating helium vapor cooled conventional current leads, interconnecting Cu-SC joints, three numbers of cryo-compatible SC feeders ducts, current leads assembly chamber, hydraulic network and three numbers of joint boxes operated at different current rating to charge Toroidal Field and Poloidal Field coils separately. During the last three campaigns, it was possible to achieve a controlled cool down up to 4 K and showed its rated operational performance. Actively cooled liquid nitrogen shield showed temperature profile in the temperature range of 80-85K and the whole system was evacuated up to 6x10 -6 mbar. The measured LHe consumption rates from TF VCCL were 0.3 g/s and 0.35 g/s at zero current and 1 kA respectively. (author)

  13. Is Current Account of Turkey Sustainable ? Evidence from Nonlinear Unit Root Tests

    Directory of Open Access Journals (Sweden)

    Serkan Taştan

    2015-09-01

    Full Text Available In this paper, current account sustainability of Turkey is analyzed in a nonlinear framework. Various nonlinear unit root tests have been used to test for structural break, sign and size nonlinearity. We have tested structural break and size nonlinearity separately and structural break-sign and size-sign nonlinearities simultaneously. Only considering the size nonlinearity, we have found that the current account of Turkey is sustainable. Thus, the size nonlinearity, in other words the speed of reversion to equilibrium, is essential for the current account sustainability of Turkey. We have also found that the speed of adjustment towards equilibrium is symmetric, while considering size and sign nonlinearities simultaneously.

  14. Application of wavelet analysis to signal processing methods for eddy-current test

    International Nuclear Information System (INIS)

    Chen, G.; Yoneyama, H.; Yamaguchi, A.; Uesugi, N.

    1998-01-01

    This study deals with the application of wavelet analysis to detection and characterization of defects from eddy-current and ultrasonic testing signals of a low signal-to-noise ratio. Presented in this paper are the methods for processing eddy-current testing signals of heat exchanger tubes of a steam generator in a nuclear power plant. The results of processing eddy-current testing signals of tube testpieces with artificial flaws show that the flaw signals corrupted by noise and/or non-defect signals can be effectively detected and characterized by using the wavelet methods. (author)

  15. Are Current Accounts of Asian Economies Mean-reverting?: Nonlinear Unit Root Test Approach

    Directory of Open Access Journals (Sweden)

    Bonghan Kim

    2005-12-01

    Full Text Available This paper tests the mean reverting property of current account in the financial crisis-affected 5 counties of southeast Asia using nonlinear unit root tests of Park and shintani(2004. Our approach is based on the idea that a conventional unit root test has lower power in detecting the nonlinear mean reverting behavior if the current account follows a nonlinear mean reversion process. We obtained following empirical results. First, for the pre-crisis period (1981Q1-1996Q4, the current accounts of Indonesia, Malaysia and Philippines are mean-reverting but those of Korea and Thailand are not mean-reverting. Second, for the full sample period (1981Q1-2003Q4, the ADF test fails to reject the unit root of the current account in all countries except Philippines. However, unit root is rejected in favor of nonlinear mean reversion except Thailand. This nonlinear unit root test result implies that crisis-affected Asian countries except Thailand have sustainable paths of current accounts. Third, when the current accounts of East Asian countries are nonlinear mean-reverting, the mean reverting process can be well described by the ESTAR model, instead of the DTAR or DLSTAR model. The nonlinear unit root test results imply smooth nonlinear mean-reversion behaviors of East Asian current accounts. Finally, the shape of estimated impulse response functions becomes steeper as the size of shock increases, which is the very characteristic of the nonlinear process.

  16. QUASI-RANDOM TESTING OF COMPUTER SYSTEMS

    Directory of Open Access Journals (Sweden)

    S. V. Yarmolik

    2013-01-01

    Full Text Available Various modified random testing approaches have been proposed for computer system testing in the black box environment. Their effectiveness has been evaluated on the typical failure patterns by employing three measures, namely, P-measure, E-measure and F-measure. A quasi-random testing, being a modified version of the random testing, has been proposed and analyzed. The quasi-random Sobol sequences and modified Sobol sequences are used as the test patterns. Some new methods for Sobol sequence generation have been proposed and analyzed.

  17. Testing system for a fuel cells stack

    International Nuclear Information System (INIS)

    Culcer, Mihai; Iliescu, Mariana; Stefanescu, Ioan; Raceanu, Mircea; Enache, Adrian; Lazar, Roxana Elena

    2006-01-01

    Hydrogen and electricity together represent one of the most promising ways to realize sustainable energy, whilst fuel cells provide the most efficient conversion devices for converting hydrogen and possibly other fuels into electricity. Thus, the development of fuel cell technology is currently being actively pursued worldwide. Due to its simple operation and other fair characteristics, the Proton Exchange Membrane Fuel Cell (PEMFC) is especially suitable as a replacement for the internal combustion engine. The PEMFC is also being developed for decentralized electricity and heat generation in buildings and mobile applications. Starting with 2001 the Institute of Research - Development for Cryogenics and Isotopic Technologies - ICIT - Rm. Valcea developed research activities supported by the Romanian Ministry of Education and Research within the National Research Program in order to bridge the gap to European competencies in the area of hydrogen and fuel cells. The paper deals with the testing system designed and developed in ICIT Rm. Valcea as a flexible and versatile tool allowing a large scale of parameter settings and measurements on a single cell or on a fuel cells stack onto a wind range of output power values. (authors)

  18. Development and Testing of a Transmission Voltage SuperLimiter™ Fault Current Limiter

    Energy Technology Data Exchange (ETDEWEB)

    Romanosky, Walter [American Superconductor Corporation, Devens, MA (United States)

    2012-09-01

    This report summarizes work by American Superconductor (AMSC), Los Alamos National Laboratory (LANL), Nexans, Siemens and Southern California Edison on a 138kV resistive type high temperature superconductor (HTS) fault current limiter (FCL) under a cooperative agreement with the U.S. Department of Energy (DOE). Phase 1A encompassed core technology development and system design and was previously reported (see summary that follows in Section 1.1 of the Introduction). This report primarily discusses work performed during Phase 1B, and addresses the fabrication and test of a single-phase prototype FCL. The results are presented along with a discussion of requirements/specifications and lessons learned to aid future development and product commercialization.

  19. Tutoring system for nondestructive testing using computer

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Jin Koo; Koh, Sung Nam [Joong Ang Inspection Co.,Ltd., Seoul (Korea, Republic of); Shim, Yun Ju; Kim, Min Koo [Dept. of Computer Engineering, Aju University, Suwon (Korea, Republic of)

    1997-10-15

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing.

  20. Tutoring system for nondestructive testing using computer

    International Nuclear Information System (INIS)

    Kim, Jin Koo; Koh, Sung Nam; Shim, Yun Ju; Kim, Min Koo

    1997-01-01

    This paper is written to introduce a multimedia tutoring system for nondestructive testing using personal computer. Nondestructive testing, one of the chief methods for inspecting welds and many other components, is very difficult for the NDT inspectors to understand its technical basis without a wide experience. And it is necessary for considerable repeated education and training for keeping their knowledge. The tutoring system that can simulate NDT works is suggested to solve the above problem based on reasonable condition. The tutoring system shows basic theories of nondestructive testing in a book-style with video images and hyper-links, and it offers practices, in which users can simulate the testing equipment. The book-style and simulation practices provide effective and individual environments for learning nondestructive testing.

  1. Radioactive waste incineration system cold demonstration test

    Energy Technology Data Exchange (ETDEWEB)

    Hozumi, Masahiro; Takaoku, Yoshinobu; Koyama, Shigeru; Nagae, Madoka; Seike, Yasuhiko; Yamanaka, Yasuhiro; Shibata, Kenji; Manabe, Kyoichi

    1984-12-01

    To demonstrate Waste Incineration System (WIS) which our company has been licensed by Combustion Engineering Inc., USA we installed a demonstration test plant in our Hiratsuka Research Laboratory and started the demonstration test on January 1984. One of the characteristics of this system is to be able to process many kinds of wastes with only one system, and to get high volume reduction factors. In our test plant, we processed paper, cloth, wood, polyethylene sheets as the samples of solid combustible wastes and spent ion exchange resins with incineration and processed condensed liquid wastes with spray drying. We have got good performances and enough Decontamination Factor (DF) data for the dust control equipment. In this paper, we introduce this demonstration test plant and report the test results up to date. (author).

  2. A computer-controlled automated test system for fatigue and fracture testing

    International Nuclear Information System (INIS)

    Nanstad, R.K.; Alexander, D.J.; Swain, R.L.; Hutton, J.T.; Thomas, D.L.

    1989-01-01

    A computer-controlled system consisting of a servohydraulic test machine, an in-house designed test controller, and a desktop computer has been developed for performing automated fracture toughness and fatigue crack growth testing both in the laboratory and in hot cells for remote testing of irradiated specimens. Both unloading compliance and dc-potential drop can be used to monitor crack growth. The test controller includes a dc-current supply programmer, a function generator for driving the servohydraulic test machine to required test outputs, five measurement channels (each consisting of low-pass filter, track/hold amplifier, and 16-bit analog-to-digital converter), and digital logic for various control and data multiplexing functions. The test controller connects to the computer via a 16-bit wide photo-isolated bidirectional bus. The computer, a Hewlett-Packard series 200/300, inputs specimen and test parameters from the operator, configures the test controller, stores test data from the test controller in memory, does preliminary analysis during the test, and records sensor calibrations, specimen and test parameters, and test data on flexible diskette for later recall and analysis with measured initial and final crack length information. During the test, the operator can change test parameters as necessary. 24 refs., 6 figs

  3. Preoperational test report, raw water system

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-10-29

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  4. Preoperational test report, raw water system

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents the preoperational test report for the Raw Water System, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The system supplies makeup water to the W-030 recirculation evaporative cooling towers for tanks AY1O1, AY102, AZ1O1, AZ102. The Raw Water pipe riser and associated strainer and valving is located in the W-030 diesel generator building. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  5. AUTOMATED MEASURING COMPLEX FOR ACCEPTANCE TESTING OF DC AND UNDULATED-CURRENT TRACTION MOTORS

    Directory of Open Access Journals (Sweden)

    A. Yu. Drubetskyi

    2016-12-01

    Full Text Available Purpose. In the paper it is necessary: 1 to familiarize the reader with the modern classification of measurement and diagnostics, familiarize with problems of automating the measurement of basic parameters during program execution of qualification tests of traction motors; 2 to make recommendations to improve the measurement ac-curacy, reduce labor intensity of work for carrying out measurements, and reduce the requirements for the qualification of the staff; 3 to provide practical implementation of measurement system, built on the basis of the practical recommendations contained in the article. Methodology. The work presents the classification of measurement and diagnostic tools. The author considered a list of equipment that can be used in measurement systems, as well as third-party options for measuring complex and measuring complex using stand management system. Their functional schemes were proposed. The author compared the advantages and disadvantages of these schemes to make recommendations on areas of their optimal use. Findings. Having analyzed the functional scheme of measuring systems, it was found that the use of the control system microcontroller as a measuring complex is expedient if the measurements have largely a test process control function. The use of a third-party measuring complex is more appropriate in cases when it is required: to eliminate dependence on the stand management system, to provide high mobility and reduce the requirements for the qualification of the staff. Originality. The work presents a brief over-view of the measurement means. The author developed the functional schemes of measuring systems using stand management system and third-party measuring complex, proposed the criteria for evaluating their optimal use. Practical value. Based on the proposed functional diagram, the measuring system on National Instruments hard-ware and software basis was set up. The sensors by LEM Company were used as primary

  6. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportio......This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional......-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions....... First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results...

  7. Multisignal detecting system of pile integrity testing

    Science.gov (United States)

    Liu, Zuting; Luo, Ying; Yu, Shihai

    2002-05-01

    The low strain reflection wave method plays a principal rule in the integrating detection of base piles. However, there are some deficiencies with this method. For example, there is a blind area of detection on top of the tested pile; it is difficult to recognize the defects at deep-seated parts of the pile; there is still the planar of 3D domino effect, etc. It is very difficult to solve these problems only with the single-transducer pile integrity testing system. A new multi-signal piles integrity testing system is proposed in this paper, which is able to impulse and collect signals on multiple points on top of the pile. By using the multiple superposition data processing method, the detecting system can effectively restrain the interference and elevate the precision and SNR of pile integrity testing. The system can also be applied to the evaluation of engineering structure health.

  8. Exemplar PV system for test and development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    This report describes the construction of Reference Photovoltaic System for Test and Development at University of Southampton between April 1995 and June 2000, which subsequently became known as the STaR Facility. (author)

  9. New current control based MPPT technique for single stage grid connected PV systems

    International Nuclear Information System (INIS)

    Jain, Sachin; Agarwal, Vivek

    2007-01-01

    This paper presents a new maximum power point tracking algorithm based on current control for a single stage grid connected photovoltaic system. The main advantage of this algorithm comes from its ability to predict the approximate amplitude of the reference current waveform or power that can be derived from the PV array with the help of an intermediate variable β. A variable step size for the change in reference amplitude during initial tracking helps in fast tracking. It is observed that if the reference current amplitude is greater than the array capacity, the system gets unstable (i.e. moves into the positive slope region of the p-v characteristics of the array). The proposed algorithm prevents the PV system from entering the positive slope region of the p-v characteristics. It is also capable of restoring stability if the system goes unstable due to a sudden environmental change. The proposed algorithm has been tested on a new single stage grid connected PV configuration recently developed by the authors to feed sinusoidal current into the grid. The system is operated in a continuous conduction mode to realize advantages such as low device current stress, high efficiency and low EMI. A fast MPPT tracker with single stage inverter topology operating in CCM makes the overall system highly efficient. Specific cases of the system, operating in just discontinuous current mode and discontinuous current mode and their relative merits and demerits are also discussed

  10. Defect detectability of eddy current testing for underwater laser beam welding

    International Nuclear Information System (INIS)

    Ueno, Souichi; Kobayashi, Noriyasu; Ochiai, Makoto; Kasuya, Takashi; Yuguchi, Yasuhiro

    2011-01-01

    We clarified defect detectability of eddy current testing (ECT) as a surface inspection technique for underwater laser beam welding works of dissimilar metal welding (DMW) of reactor vessel nozzle. The underwater laser beam welding procedure includes groove caving as a preparation, laser beam welding in the grooves and welded surface grinding as a post treatment. Therefore groove and welded surface inspections are required in the underwater condition. The ECT is a major candidate as this inspection technique because a penetrant testing is difficult to perform in the underwater condition. Several kinds of experiments were curried out using a cross coil an ECT probe and ECT data acquisition system in order to demonstrate the ECT defect detectability. We used specimens, simulating groove and DMW materials at an RV nozzle, with electro-discharge machining (EDM) slits over it. Additionally, we performed a detection test for artificial stress corrosion cracking (SCC) defects. From these experimental results, we confirmed that an ECT was possible to detect EDM slits 0.3 mm or more in depth and artificial SCC defects 0.02 mm to 0.48 mm in depth on machined surface. Furthermore, the underwater ECT defect detectability is equivalent to that in air. We clarified an ECT is sufficiently usable as a surface inspection technique for underwater laser beam welding works. (author)

  11. Artificial intelligence and expert systems in-flight software testing

    Science.gov (United States)

    Demasie, M. P.; Muratore, J. F.

    1991-01-01

    The authors discuss the introduction of advanced information systems technologies such as artificial intelligence, expert systems, and advanced human-computer interfaces directly into Space Shuttle software engineering. The reconfiguration automation project (RAP) was initiated to coordinate this move towards 1990s software technology. The idea behind RAP is to automate several phases of the flight software testing procedure and to introduce AI and ES into space shuttle flight software testing. In the first phase of RAP, conventional tools to automate regression testing have already been developed or acquired. There are currently three tools in use.

  12. Prototype Engineered Barrier System Field Tests

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Beatty, J.; Buscheck, T.A.

    1989-01-01

    This paper presents selected preliminary results obtained during the first 54 days of the Prototype Engineered Barrier System Field Tests (PEBSFT) that are being performed in G-Tunnel within the Nevada Test Site. The test described is a precursor to the Engineered Barrier Systems Field Tests (EBSFT). The EBSFT will consist of in situ tests of the geohydrologic and geochemical environment in the near field (within a few meters) of heaters emplaced in welded tuff to simulate the thermal effects of waste packages. The PEBSFTs are being conducted to evaluate the applicability of measurement techniques, numerical models, and procedures for future investigations that will be conducted in the Exploratory Shaft Facilities of the Yucca Mountain Project (YMP). The paper discusses the evolution of hydrothermal behavior during the prototype test, including rock temperatures, changes in rock moisture content, air permeability of fractures, gas pressures, and rock mass gas-phase humidity. 10 refs., 12 figs

  13. Orion Boiler Plate Airdrop Test System

    Science.gov (United States)

    Machin, Ricardo A.; Evans, Carol T.

    2013-01-01

    On the 29th of February 2012 the Orion Capsule Parachute Assembly System (CPAS) project attempted to perform an airdrop test of a boilerplate test article for the second time. The first attempt (Cluster Development Test 2, July 2008) to deliver a similar boilerplate from a C-17 using the Low Velocity Air Drop (LVAD) technique resulted in the programmer parachute failing to properly inflate, the test article failing to achieve the desired test initiation conditions, and the test article a total loss. This paper will pick up where the CDT-2 failure investigation left off, describing the test technique that was adopted, and outline the modeling that was performed to gain confidence that the second attempt would be successful. The second boiler plate test (Cluster Development Test 3-3) was indeed a complete success and has subsequently been repeated several times, allowing the CPAS project to proceed with the full scale system level development testing required to integrate the hardware to the first Entry Flight Test vehicle as well as go into the Critical Design Review with minimum risk and a mature design.

  14. Stress Testing of Transactional Database Systems

    OpenAIRE

    Meira , Jorge Augusto; Cunha De Almeida , Eduardo; Sunyé , Gerson; Le Traon , Yves; Valduriez , Patrick

    2013-01-01

    International audience; Transactional database management systems (DBMS) have been successful at supporting traditional transaction processing workloads. However, web-based applications that tend to generate huge numbers of concurrent business operations are pushing DBMS performance over their limits, thus threatening overall system availability. Then, a crucial question is how to test DBMS performance under heavy workload conditions. Answering this question requires a testing methodology to ...

  15. The Regional Test Center Data Transfer System

    Energy Technology Data Exchange (ETDEWEB)

    Riley, Daniel M. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Dept.; Stein, Joshua S. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Photovoltaic and Distributed Systems Dept.

    2016-09-01

    The Regional Test Centers are a group of several sites around the US for testing photovoltaic systems and components related to photovoltaic systems. The RTCs are managed by Sandia National Laboratories. The data collected by the RTCs must be transmitted to Sandia for storage, analysis, and reporting. This document describes the methods that transfer the data between remote sites and Sandia as well as data movement within Sandia’s network. The methods described are in force as of September, 2016.

  16. Development of autonomous vehicles’ testing system

    Science.gov (United States)

    Ivanov, A. M.; Shadrin, S. S.

    2018-02-01

    This article describes overview of automated and, in perspective, autonomous vehicles’ (AV) implementation risks. Set of activities, actual before the use of AVs on public roads, minimizing negative technical and social problems of AVs’ implementation is presented. Classification of vehicle’s automated control systems operating conditions is formulated. Groups of tests for AVs are developed and justified, sequence of AVs’ testing system formation is proposed.

  17. Current Status on the Korean Test Blanket Module Development for testing in the ITER

    International Nuclear Information System (INIS)

    Lee, Dong Won; Kim, Suk Kwon; Bae, Young Dug; Yoon, Jae Sung; Jung, Ki Sok

    2010-01-01

    Korea has proposed and designed a Helium Cooled Molten Lithium (HCML) Test Blanket Module (TBM) to be tested in the International Thermonuclear Experimental Reactor (ITER). Ferrite Martensitic (FM) steel is used as the structural material and helium (He) is used as a coolant to cool the first wall (FW) and breeding zone. Liquid lithium (Li) is circulated for a tritium breeding, not for a cooling purpose. Main purpose for developing the TBM is to develop the design technology for DEMO and fusion reactor and it should be proved through the experiment in the ITER with TBM. Therefore, we have developed the design scheme and related codes including the safety analysis for obtain the license to be tested in the ITER. In order to develop and install at the ITER, several technologies were developed in parallel; fabrication, breeder, He cooling, tritium extraction and so on. Figure 1 shows the overall TBM development scheme. In Korea, official strategy for developing the TBM is to participate to other parties' concept such as US and EU ones, in which PbLi (lead lithium eutectic), He, and FM steel were used for liquid breeder, coolant, and structural material, respectively

  18. Stability properties of cold blanket systems for current driven modes

    International Nuclear Information System (INIS)

    Ohlsson, D.

    1977-12-01

    The stability problem of the boundary regions of cold blanket systems with induced currents parallel to the lines of force is formulated. Particular interest is focused on two types of modes: first electrostatic modes driven by the combined effects of a transverse resistivity gradient due to a spatially non-uniform electron temperature and a longitudinal current, second electromagnetic kink like modes driven by the torque arising from a transverse current density gradient and magnetic field perturbations. It is found that the combination of various dissipative and neutral gas effects introduces strong stabilizing effects within specific parameter ranges. For particular steady-state models investigated it is shown that these effects become of importance in laboratory plasmas at relatively high densities, low temperatures and moderate magnetic field strengths. Stability diagrams based on specific steady-state cold plasma blanket models will be presented

  19. Railcar waste transfer system hydrostatic test

    International Nuclear Information System (INIS)

    Ellingson, S.D.

    1997-01-01

    Recent modifications have been performed on the T-Plant Railcar Waste Transfer System, This Acceptance Test Procedure (ATP) has been prepared to demonstrate that identified piping welds and mechanical connections incorporated during the modification are of high integrity and are acceptable for service. This will be achieved by implementation of a hydrostatic leak test

  20. Acceptance test report: Backup power system

    International Nuclear Information System (INIS)

    Cole, D.B.

    1996-01-01

    Acceptance Test Report for construction functional testing of Project W-030 Backup Power System. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. Backup power includes a single 125 KW diesel generator, three 10-kva uninterruptible power supply units, and all necessary control

  1. Resistance temperature sensor aging degradation identification using LCSR (Loop Current Step Response) test

    International Nuclear Information System (INIS)

    Santos, Roberto Carlos dos; Goncalves, Iraci Martine Pereira

    2013-01-01

    Most critical process temperatures in nuclear power plants are measured using RTD (Resistance Temperature Detector) and thermocouples. In a PWR (Pressure Water Reactor) plant, the primary coolant temperature and feedwater temperature are measured using RTDs, and the temperature of the water that exits the reactor core is measured using thermocouples. These thermocouples are mainly used for temperature monitoring purposes and are therefore not generally subject to very stringent requirements for accuracy and response-time performance. In contrast, primary coolant RTDs typically feed the plant's control and safety systems and must, therefore, be very accurate and have good dynamic performance. The response time of RTDs and thermocouples has been characterized by a single parameter called the Plunge Time Constant. This is defined as the time it takes the sensor output to achieve 63.2 percent of its final value after a step change in temperature is impressed on its surface. This step change is typically achieved by suddenly immersing the sensor in a rotating tank of water, called Plunge Test. In nuclear reactors, however, plunge testing is inconvenient because the sensor must be removed from the reactor coolant piping and taken to a laboratory for testing. Nuclear reactor service conditions of 150 bar and 300°C are difficult to reproduce in the laboratory. Therefore, all laboratory tests are performed at much milder conditions, and the results are extrapolated to service conditions. This leads to significant errors in the measurement of sensor response times and an insitu test method called LCSR - Loop Current Step Response test was developed in the mid-1970s to measure remotely the response time of RTDs. In the LCSR method, the sensing element is heated by an electric current; the current causes Joule heating in the sensor and results in a temperature transient inside the sensor. The temperature transient in the element is recorded, and from this transient, the

  2. 242A Distributed Control System Year 2000 Acceptance Test Report

    Energy Technology Data Exchange (ETDEWEB)

    TEATS, M.C.

    1999-08-31

    This report documents acceptance test results for the 242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. This report documents the test results obtained by acceptance testing as directed by procedure HNF-2695. This verification procedure will document the initial testing and evaluation of the potential 242-A Distributed Control System (DCS) operating difficulties across the year 2000 boundary and the calendar adjustments needed for the leap year. Baseline system performance data will be recorded using current, as-is operating system software. Data will also be collected for operating system software that has been modified to correct year 2000 problems. This verification procedure is intended to be generic such that it may be performed on any D/3{trademark} (GSE Process Solutions, Inc.) distributed control system that runs with the VMSTM (Digital Equipment Corporation) operating system. This test may be run on simulation or production systems depending upon facility status. On production systems, DCS outages will occur nine times throughout performance of the test. These outages are expected to last about 10 minutes each.

  3. 242A Distributed Control System Year 2000 Acceptance Test Report

    International Nuclear Information System (INIS)

    TEATS, M.C.

    1999-01-01

    This report documents acceptance test results for the 242-A Evaporator distributive control system upgrade to D/3 version 9.0-2 for year 2000 compliance. This report documents the test results obtained by acceptance testing as directed by procedure HNF-2695. This verification procedure will document the initial testing and evaluation of the potential 242-A Distributed Control System (DCS) operating difficulties across the year 2000 boundary and the calendar adjustments needed for the leap year. Baseline system performance data will be recorded using current, as-is operating system software. Data will also be collected for operating system software that has been modified to correct year 2000 problems. This verification procedure is intended to be generic such that it may be performed on any D/3(trademark) (GSE Process Solutions, Inc.) distributed control system that runs with the VMSTM (Digital Equipment Corporation) operating system. This test may be run on simulation or production systems depending upon facility status. On production systems, DCS outages will occur nine times throughout performance of the test. These outages are expected to last about 10 minutes each

  4. Current technological trends in development of NPP systems

    International Nuclear Information System (INIS)

    Florescu, Gheorghe; Panaitescu, Valeriu

    2010-01-01

    The recent nuclear research issues look for new technologies and continuous progress in finding different and efficient solutions for sustained and upraising energy demand. The trend of increasing energy consumption and occurring of new and large consumers, especially from Asian countries, imposes finding of new means for clean, large scale and sustained energy production. NPPs availability was continuously monitored and improved; at the same time the safety of the nuclear energy production was under surveillance. The present development of the new technologies, the discoveries of new materials and development of efficient technological processes offer the opportunities for their appropriate implementation and use in the NPP system configurations and functioning/operation. The new technologies and scientific discoveries, and also the international cooperation, offer the opportunities to mitigate the actual barriers in order to cumulate and use advanced energy production, to find new energy sources and to build improved, reliable and safe power plants. The monitoring systems, intelligent sensors and SSCs, nanotechnologies and new/intelligent materials constitute the main ways for improvement of the NPP systems configuration and processes. The paper presents: - The state of the art in the level of the currently applied technologies for nuclear power systems development; - The actual technological limits that need to be over passed for improving the NPP systems ; - The main systems that need improvement and reconfiguration for development of currently operating NPPs as well as raising the operation efficiency, availability and total safety; - The actual energy production issues; - The key arguments in sustaining the R and D new NPP systems development; - Future trends in NPP development; - The limitations in industrial processes knowledge and use. Appropriate R and D in the field of NPP systems have specific characteristics that were considered in paper completion

  5. Elements of a system for verifying a Comprehensive Test Ban

    International Nuclear Information System (INIS)

    Hannon, W.J.

    1987-01-01

    The paper discusses the goals of a monitoring system for a CTB, its functions, the challenges to verification, discrimination techniques, and some recent developments. It is concluded technical, military and political efforts are required to establish and verify test ban treaties which will contribute to stability in the long term. It currently appears there will be a significant number of unidentified events

  6. 'I think it will eventually be done away with': Attitudes among healthcare professionals towards the current system of animal experimentation.

    Science.gov (United States)

    Dignon, Andrée

    2016-08-01

    This article describes a study of attitudes to the current system of animal experimentation (for the production of health interventions) among 52 UK healthcare professionals. These healthcare professionals participated in three separate focus groups (of 18, 17 and 17 participants) and were invited to respond to the question 'what is your opinion about the current system of animal testing?' The study focused specifically on their views of the current system (rather than their views of animal testing in general). The healthcare professionals were critical of the current system, particularly with regard to regulation, secrecy, validity, unnecessary suffering and welfare. © The Author(s) 2014.

  7. Smart wearable systems: current status and future challenges.

    Science.gov (United States)

    Chan, Marie; Estève, Daniel; Fourniols, Jean-Yves; Escriba, Christophe; Campo, Eric

    2012-11-01

    Extensive efforts have been made in both academia and industry in the research and development of smart wearable systems (SWS) for health monitoring (HM). Primarily influenced by skyrocketing healthcare costs and supported by recent technological advances in micro- and nanotechnologies, miniaturisation of sensors, and smart fabrics, the continuous advances in SWS will progressively change the landscape of healthcare by allowing individual management and continuous monitoring of a patient's health status. Consisting of various components and devices, ranging from sensors and actuators to multimedia devices, these systems support complex healthcare applications and enable low-cost wearable, non-invasive alternatives for continuous 24-h monitoring of health, activity, mobility, and mental status, both indoors and outdoors. Our objective has been to examine the current research in wearable to serve as references for researchers and provide perspectives for future research. Herein, we review the current research and development of and the challenges facing SWS for HM, focusing on multi-parameter physiological sensor systems and activity and mobility measurement system designs that reliably measure mobility or vital signs and integrate real-time decision support processing for disease prevention, symptom detection, and diagnosis. For this literature review, we have chosen specific selection criteria to include papers in which wearable systems or devices are covered. We describe the state of the art in SWS and provide a survey of recent implementations of wearable health-care systems. We describe current issues, challenges, and prospects of SWS. We conclude by identifying the future challenges facing SWS for HM. Copyright © 2012 Elsevier B.V. All rights reserved.

  8. Built-in current sensor for ΔIDDQ testing of deep submicron digital CMOS ICs

    NARCIS (Netherlands)

    Vazquez, J.R.; Pineda de Gyvez, J.

    2004-01-01

    This paper presents the implementation of a built-in current sensor that includes two recently reported new techniques for IDDQ testing to take into account the increased background current of defect-free circuits and its increased variance due to process variations. These techniques are the

  9. Current status of quality assurance of treatment planning systems

    International Nuclear Information System (INIS)

    Mijnheer, B.J.

    1997-01-01

    A review is given of the current status of quality assurance of treatment planning systems. At this moment only one comprehensive report is available. In order to review national activities a questionnaire has been distributed amongst national societies of medical physicists. From the 23 responding countries, 8 indicated that only limited efforts are underway, 8 answered that a working group is evaluating their specific national requirements while in 5 countries a document is drafted. The highlights of these reports have been summarized. (author)

  10. Design of electronic measurement and quench detection equipment for the Current Lead Test facility Karlsruhe (CuLTKa)

    International Nuclear Information System (INIS)

    Hollik, Markus; Fietz, Walter H.; Fink, Stefan; Gehrlein, Mirko; Heller, Reinhard; Lange, Christian; Möhring, Tobias

    2013-01-01

    The Current Lead Test facility Karlsruhe (CuLTKa) is under construction at the Karlsruhe Institute of Technology (KIT) to perform acceptance tests of high temperature superconductor (HTS) current leads (CL). CuLTKa is in progress and present planning expects the completion in 2013. The data acquisition system is based on a modular design with electronic measurement and monitoring equipment covering a test voltage of 50 kV DC against ground. It provides plug-in units which enable temperature and voltage measurement at high voltage potential and in addition quench detection units which detect a loss of superconductivity reliably and quickly to avoid damage of the superconducting device under test. Prototype units for quench detection, temperature and voltage measurement have been successfully tested. Six temperature measurement units are already in use in the KIT test facility TOSKA and operated reliably during the acceptance tests of the HTS current leads for Wendelstein 7-X (W7-X) in 2011/2012. CuLTKa will be used first for 26 current leads which will be built in KIT for the fusion experiment JT-60SA. The present paper gives an overview of the design of the electronic measurement and quench detection equipment

  11. Electric machine and current source inverter drive system

    Science.gov (United States)

    Hsu, John S

    2014-06-24

    A drive system includes an electric machine and a current source inverter (CSI). This integration of an electric machine and an inverter uses the machine's field excitation coil for not only flux generation in the machine but also for the CSI inductor. This integration of the two technologies, namely the U machine motor and the CSI, opens a new chapter for the component function integration instead of the traditional integration by simply placing separate machine and inverter components in the same housing. Elimination of the CSI inductor adds to the CSI volumetric reduction of the capacitors and the elimination of PMs for the motor further improve the drive system cost, weight, and volume.

  12. Neoclassical current and plasma rotation in helical systems

    International Nuclear Information System (INIS)

    Nakajima, N.; Okamoto, M.

    1991-01-01

    In order to clarify geometrical effects of the magnetic field on the neoclassical theory in general toroidal systems, the neoclassical parallel particle flow, heat flux, current and plasma rotation of a multispecies plasma are examined using the moment approach on the basis of the original papers under the assumptions of no fluctuations, no external sources and losses except for a fast ion beam and an external inductive electric field, steady state, and |u a | Ta where u a and v Ta are the macro and thermal velocity of species a, respectively. Hence, we might have a point of view of unifying understanding the neoclassical theory in general toroidal systems. Three collisionality regimes, i.e., the 1/ν (in non-axisymmetric toroidal systems) or banana (in axisymmetric toroidal systems), plateau, and Pfirsch-Schlueter collisionality regimes are examined separately. (author) 8 refs

  13. Methodology for simulation of geomagnetically induced currents in power systems

    Directory of Open Access Journals (Sweden)

    Boteler David

    2014-07-01

    Full Text Available To assess the geomagnetic hazard to power systems it is useful to be able to simulate the geomagnetically induced currents (GIC that are produced during major geomagnetic disturbances. This paper examines the methodology used in power system analysis and shows how it can be applied to modelling GIC. Electric fields in the area of the power network are used to determine the voltage sources or equivalent current sources in the transmission lines. The power network can be described by a mesh impedance matrix which is combined with the voltage sources to calculate the GIC in each loop. Alternatively the power network can be described by a nodal admittance matrix which is combined with the sum of current sources into each node to calculate the nodal voltages which are then used to calculate the GIC in the transmission lines and GIC flowing to ground at each substation. Practical calculations can be made by superposition of results calculated separately for northward and eastward electric fields. This can be done using magnetic data from a single observatory to calculate an electric field that is a uniform approximation of the field over the area of the power system. It is also shown how the superposition of results can be extended to use data from two observatories: approximating the electric field by a linear variation between the two observatory locations. These calculations provide an efficient method for simulating the GIC that would be produced by historically significant geomagnetic storm events.

  14. Current Status of the Beam Position Monitoring System at TLS

    Science.gov (United States)

    Kuo, C. H.; Hu, K. H.; Chen, Jenny; Lee, Demi; Wang, C. J.; Hsu, S. Y.; Hsu, K. T.

    2006-11-01

    The beam position monitoring system is an important part of a synchrotron light source that supports its routine operation and studies of beam physics. The Taiwan light source is equipped with 59 BPMs. Highly precise closed orbits are measured by multiplexing BPMs. Data are acquired using multi-channel 16-bit ADC modules. Orbit data are sampled every millisecond. Fast orbit data are shared in a reflective memory network to support fast orbit feedback. Averaged data were updated to control database at a rate of 10 Hz. A few new generation digital BPMs were tested to evaluate their performance and functionality. This report summarizes the system structure, the software environment and the preliminary beam test of the BPM system.

  15. RHIC sextant test: Accelerator systems and performance

    Energy Technology Data Exchange (ETDEWEB)

    Pilat, F.; Trbojevic, D.; Ahrens, L. [and others

    1997-08-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning.

  16. RHIC sextant test: Accelerator systems and performance

    International Nuclear Information System (INIS)

    Pilat, F.; Trbojevic, D.; Ahrens, L.

    1997-01-01

    One sextant of the RHIC Collider was commissioned in early 1997 with beam. We describe here the performance of the accelerator systems, instrumentation subsystems and application software. We also describe a ramping test without beam that took place after the commissioning with beam. Finally, we analyze the implications of accelerator systems performance and their impact on the planning for RHIC installation and commissioning

  17. The BNL Accelerator Test Facility control system

    International Nuclear Information System (INIS)

    Malone, R.; Bottke, I.; Fernow, R.; Ben-Zvi, I.

    1993-01-01

    Described is the VAX/CAMAC-based control system for Brookhaven National Laboratory's Accelerator Test Facility, a laser/linac research complex. Details of hardware and software configurations are presented along with experiences of using Vsystem, a commercial control system package

  18. Medical telerobotic systems: current status and future trends.

    Science.gov (United States)

    Avgousti, Sotiris; Christoforou, Eftychios G; Panayides, Andreas S; Voskarides, Sotos; Novales, Cyril; Nouaille, Laurence; Pattichis, Constantinos S; Vieyres, Pierre

    2016-08-12

    Teleoperated medical robotic systems allow procedures such as surgeries, treatments, and diagnoses to be conducted across short or long distances while utilizing wired and/or wireless communication networks. This study presents a systematic review of the relevant literature between the years 2004 and 2015, focusing on medical teleoperated robotic systems which have witnessed tremendous growth over the examined period. A thorough insight of telerobotics systems discussing design concepts, enabling technologies (namely robotic manipulation, telecommunications, and vision systems), and potential applications in clinical practice is provided, while existing limitations and future trends are also highlighted. A representative paradigm of the short-distance case is the da Vinci Surgical System which is described in order to highlight relevant issues. The long-distance telerobotics concept is exemplified through a case study on diagnostic ultrasound scanning. Moreover, the present review provides a classification into short- and long-distance telerobotic systems, depending on the distance from which they are operated. Telerobotic systems are further categorized with respect to their application field. For the reviewed systems are also examined their engineering characteristics and the employed robotics technology. The current status of the field, its significance, the potential, as well as the challenges that lie ahead are thoroughly discussed.

  19. Rocket Testing and Integrated System Health Management

    Science.gov (United States)

    Figueroa, Fernando; Schmalzel, John

    2005-01-01

    Integrated System Health Management (ISHM) describes a set of system capabilities that in aggregate perform: determination of condition for each system element, detection of anomalies, diagnosis of causes for anomalies, and prognostics for future anomalies and system behavior. The ISHM should also provide operators with situational awareness of the system by integrating contextual and timely data, information, and knowledge (DIaK) as needed. ISHM capabilities can be implemented using a variety of technologies and tools. This chapter provides an overview of ISHM contributing technologies and describes in further detail a novel implementation architecture along with associated taxonomy, ontology, and standards. The operational ISHM testbed is based on a subsystem of a rocket engine test stand. Such test stands contain many elements that are common to manufacturing systems, and thereby serve to illustrate the potential benefits and methodologies of the ISHM approach for intelligent manufacturing.

  20. Test plan for qualification testing of the 241-SY-101 Flexible Receiver System

    International Nuclear Information System (INIS)

    Ritter, G.A.

    1994-01-01

    A mixer pump was installed in tank 241-SY-101 on July 3, 1993, to support hydrogen mitigation testing. This test mixer pump has proven to be very successful in mitigating the large gas releases, or ''burps,'' from the tank waste. Therefore, a decision has been made to fabricate a spare pump that will be installed upon failure of the existing test pump. Before replacement activities can be initiated, equipment must be available to remove the existing pump. A pump removal system is currently being designed and fabricated that will support the retrieval, transportation and disposal of the existing pump. The Equipment Removal System consists of six major components: the flexible receiver system (FRS), the equipment storage container, the container strongback system, the container transport trailer, the support cranes, and the pump washdown system

  1. Standardization of penetrating radiation testing system

    International Nuclear Information System (INIS)

    Wiley, P.A.; Aronson, H.L.

    1979-01-01

    Standardization is provided to control system gain of a penetrating radiation testing system by periodically inspecting a reference object in the same manner as the product samples so as to generate a stabilization signal which is compared to a reference signal. The difference, if any, between the stabilization signal and the reference signal is integrated and the integrated signal is used to correct the gain of the system

  2. Test-driven modeling of embedded systems

    DEFF Research Database (Denmark)

    Munck, Allan; Madsen, Jan

    2015-01-01

    To benefit maximally from model-based systems engineering (MBSE) trustworthy high quality models are required. From the software disciplines it is known that test-driven development (TDD) can significantly increase the quality of the products. Using a test-driven approach with MBSE may have...... a similar positive effect on the quality of the system models and the resulting products and may therefore be desirable. To define a test-driven model-based systems engineering (TD-MBSE) approach, we must define this approach for numerous sub disciplines such as modeling of requirements, use cases...... suggest that our method provides a sound foundation for rapid development of high quality system models....

  3. Assessment of Current Practice for Tank Testing of Small Marine Energy Devices

    DEFF Research Database (Denmark)

    Kofoed, Jens Peter; Frigaard, Peter

    Discussion Report. Equitable Testing and Evaluation of Marine Energy Extraction Devices in terms of Performance, Cost and Environmental Impact. The report is a contribution by Aalborg University (AAU) to the deliverable on Assessment of current practice for tank testing of small marine energy...

  4. Alternative methods for skin irritation testing: the current status : ECVAM skin irritation task force report 1

    NARCIS (Netherlands)

    Botham, P.A.; Earl, L.K.; Fentem, J.H.; Roguet, R.; Sandt, J.J.M.

    1998-01-01

    The ECVAM Skin Irritation Task Force was established in November 1996, primarily to prepare a report on the current status of the development and validation of alternative tests for skin irritation and corrosion and, in particular, to identify any appropriate non-animal tests for predicting human

  5. Current trauma care system and trauma care training in China

    Directory of Open Access Journals (Sweden)

    Lian-Yang Zhang

    2018-04-01

    Full Text Available Trauma is a life-threatening “modern disease”. The outcomes could only be optimized by cost-efficient and prompt trauma care, which embarks on the improvement of essential capacities and conceptual revolution in addition to the disruptive innovation of the trauma care system. According to experiences from the developed countries, systematic trauma care training is the cornerstone of the generalization and the improvement on the trauma care, such as the Advance Trauma Life Support (ATLS. Currently, the pre-hospital emergency medical services (EMS has been one of the essential elements of infrastructure of health services in China, which is also fundamental to the trauma care system. Hereby, the China Trauma Care Training (CTCT with independent intellectual property rights has been initiated and launched by the Chinese Trauma Surgeon Association to extend the up-to-date concepts and techniques in the field of trauma care as well to reinforce the generally well-accepted standardized protocols in the practices. This article reviews the current status of the trauma care system as well as the trauma care training. Keywords: Trauma care system, Trauma care training, China

  6. The current situation of treatment systems for alcoholism in Korea.

    Science.gov (United States)

    Kim, Jee Wook; Lee, Boung Chul; Kang, Tae-Cheon; Choi, Ihn-Geun

    2013-02-01

    Alcoholism is becoming one of the most serious issues in Korea. The purpose of this review article was to understand the present status of the treatment system for alcoholism in Korea compared to the United States and to suggest its developmental direction in Korea. Current modalities of alcoholism treatment in Korea including withdrawal treatment, pharmacotherapy, and psychosocial treatment are available according to Korean evidence-based treatment guidelines. Benzodiazepines and supportive care including vitamin and nutritional support are mainly used to treat alcohol withdrawal in Korea. Naltrexone and acamprosate are the drugs of first choice to treat chronic alcoholism. Psychosocial treatment methods such as individual psychotherapy, group psychotherapy, family therapy, cognitive behavior therapy, cue exposure therapy, 12-step facilitation therapy, self-help group therapy, and community-based treatment have been carried out to treat chronic alcoholism in Korea. However, current alcohol treatment system in Korea is not integrative compared to that in the United States. To establish the treatment system, it is important to set up an independent governmental administration on alcohol abuse, to secure experts on alcoholism, and to conduct outpatient alcoholism treatment programs and facilities in an open system including some form of continuing care.

  7. A Low Heat Inleak Cryogenic Station for Testing HTS Current Leads for the Large Hadron Collider

    CERN Document Server

    Ballarino, A; Gomes, P; Métral, L; Serio, L; Suraci, A

    1999-01-01

    The LHC will be equipped with about 8000 superconducting magnets of all types. The total current to be transported into the cryogenic enclosure amounts to some 3360 kA. In order to reduce the heat load into the liquid helium, CERN intends to use High Temperature Superconducting (HTS) material for leads having current ratings up to 13 kA. The resistive part of the leads is cooled by forced flow of gaseous helium between 20 K and 300 K. The HTS part of the lead is immersed in a 4.5 K liquid helium bath, operates in self cooling conditions and is hydraulically separated from the resistive part. A cryogenic test station has been designed and built in order to assess the thermal and electrical performances of 13 kA prototype current leads. We report on the design, commissioning and operation of the cryogenic test station and illustrate its performance by typical test results of HTS current leads.

  8. Test results of fault current limiter using YBCO tapes with shunt protection

    Energy Technology Data Exchange (ETDEWEB)

    Baldan, Carlos A; Lamas, Jerika S; Shigue, Carlos Y [Escola de Engenharia de Lorena, EEL USP, Lorena - SP (Brazil); Filho, Ernesto Ruppert, E-mail: cabaldan@gmail.co [Faculdade de Engenharia Eletrica, FEEC Unicamp, Campinas - SP (Brazil)

    2010-06-01

    A Fault Current Limiter (FCL) based on high temperature superconducting elements with four tapes in parallel were designed and tested in 220 V line for a fault current peak between 1 kA to 4 kA. The elements employed second generation (2G) HTS tapes of YBCO coated conductor with stainless steel reinforcement. The tapes were electrically connected in parallel with effective length of 0.4 m per element (16 elements connected in series) constituting a single-phase unit. The FCL performance was evaluated through over-current tests and its recovery characteristics under load current were analyzed using optimized value of the shunt protection. The projected limiting ratio achieved a factor higher than 4 during fault of 5 cycles without degradation. Construction details and further test results will be shown in the paper.

  9. Coupling method of magnetic memory and eddy current nondestructive testing for retired crankshafts

    Energy Technology Data Exchange (ETDEWEB)

    Ni, Chen; Hua, Lin; Wang, Xiaokai; Wang, Zhou; Qin, Xunpeng; Fang, Zhou [Wuhan University of Technology, Wuhan (Korea, Republic of)

    2016-07-15

    To verify the validity of the Coupling method of magnetic memory and eddy current (CMMEC) testing for crankshafts, we use this technique to test a 12-cylinder V-design diesel crankshaft. First, the stress distribution in the crankshaft was obtained under 12 working conditions using a Finite element (FE) model that complied with the commercial FE code ABAQUS. Second, Magnetic memory testing (MMT) and Eddy current testing (ECT) were adopted to detect the regions of stress concentration in the crankshaft and the specific location of cracks based on simulation results. Lastly, magnetic particle testing was conducted to detect and display the corresponding crack to verify the CMMEC testing results. The MMT and ECT results can provide basis and guidance for the remanufacture and life evaluation of retired crankshafts.

  10. Coupling method of magnetic memory and eddy current nondestructive testing for retired crankshafts

    International Nuclear Information System (INIS)

    Ni, Chen; Hua, Lin; Wang, Xiaokai; Wang, Zhou; Qin, Xunpeng; Fang, Zhou

    2016-01-01

    To verify the validity of the Coupling method of magnetic memory and eddy current (CMMEC) testing for crankshafts, we use this technique to test a 12-cylinder V-design diesel crankshaft. First, the stress distribution in the crankshaft was obtained under 12 working conditions using a Finite element (FE) model that complied with the commercial FE code ABAQUS. Second, Magnetic memory testing (MMT) and Eddy current testing (ECT) were adopted to detect the regions of stress concentration in the crankshaft and the specific location of cracks based on simulation results. Lastly, magnetic particle testing was conducted to detect and display the corresponding crack to verify the CMMEC testing results. The MMT and ECT results can provide basis and guidance for the remanufacture and life evaluation of retired crankshafts.

  11. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Yan, W.; Henry, G.

    1999-01-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  12. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, B.R.; Yan, W. [Tennessee Univ., Knoxville, TN (United States). Dept. of Nuclear Engineering; Behravesh, M.M. [Electric Power Research Institute, Palo Alto, CA (United States); Henry, G. [EPRI NDE Center, Charlotte, NC (United States)

    1999-09-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  13. Fenestration System Performance Research, Testing, and Evaluation

    Energy Technology Data Exchange (ETDEWEB)

    Jim Benney

    2009-11-30

    The US DOE was and is instrumental to NFRC's beginning and its continued success. The 2005 to 2009 funding enables NFRC to continue expanding and create new, improved ratings procedures. Research funded by the US DOE enables increased fenestration energy rating accuracy. International harmonization efforts supported by the US DOE allow the US to be the global leader in fenestration energy ratings. Many other governments are working with the NFRC to share its experience and knowledge toward development of their own national fenestration rating process similar to the NFRC's. The broad and diverse membership composition of NFRC allows anyone with a fenestration interest to come forward with an idea or improvement to the entire fenestration community for consideration. The NFRC looks forward to the next several years of growth while remaining the nation's resource for fair, accurate, and credible fenestration product energy ratings. NFRC continues to improve its rating system by considering new research, methodologies, and expanding to include new fenestration products. Currently, NFRC is working towards attachment energy ratings. Attachments are blinds, shades, awnings, and overhangs. Attachments may enable a building to achieve significant energy savings. An NFRC rating will enable fair competition, a basis for code references, and a new ENERGY STAR product category. NFRC also is developing rating methods to consider non specular glazing such as fritted glass. Commercial applications frequently use fritted glazing, but no rating method exists. NFRC is testing new software that may enable this new rating and contribute further to energy conservation. Around the world, many nations are seeking new energy conservation methods and NFRC is poised to harmonize its rating system assisting these nations to better manage and conserve energy in buildings by using NFRC rated and labeled fenestration products. As this report has shown, much more work needs to be

  14. Basic research into eddy current testing of austenetic weld joints and surface claddings

    International Nuclear Information System (INIS)

    Meier, W.

    1976-01-01

    The result of research work has shown that the eddy-current testing method can be used for austenetic steel up to 10 mm thick to detect cracks in the material. An exception to this are laminations if they are parallel to the surface. Cracks in the various geometrical positions in the test specimen produce different results in the x-y plot. They are influenced by the direction of the material cracks. Research into the influence the geometric parameters have on the indications shows that the eddy-current method provides clearer interpretations of material cracks than any other non-destructive test method known. (orig.) [de

  15. Real time control of EC heating & current drive systems on TCV

    NARCIS (Netherlands)

    Paley, J.I.; Felici, F.; Curchod, L.; Coda, S.; Goodman, T.P.

    2009-01-01

    The ability to control, in real time, the electron cyclotron heating & current drive systems for the control of MHD instabilities is particularly important for large tokamaks operating at high performance. Several algorithms have been developed and tested on TCV to explore possible control

  16. Development of high current beam ns pulsed system

    CERN Document Server

    Shen Guan Ren; Gao Fu; Guan Xia Ling; LiuNaiYi

    2001-01-01

    The development of high current beam ns pulsed system of CPNG and its characteristic, main technological performance and application are introduced. Firstly, important parameters of the system are calculated using theoretical model, the design requirements of some important parts are understood. Some mistakes in physics conception are corrected. Second, the chopper is designed for parallel plate deflector, chopping aperture and sine wave voltage sweeping device. It is emphasized that the conception of parallel plate load impedance is the capacitance load, but not the 50 ohm load impedance. The dynamic capacitance value has been measured. The output emphasizes the output voltage amplitude, but not the output power for sweeping device. The display system of output sweeping voltage was set up and it is sure that the maximum output voltage(V-V) is >=4000 V. The klystron buncher are re-designed. It is emphasized to overcome difficulty of support high voltage electrode in the klystron and insulator of input sine wa...

  17. Current understanding of interactions between nanoparticles and the immune system.

    Science.gov (United States)

    Dobrovolskaia, Marina A; Shurin, Michael; Shvedova, Anna A

    2016-05-15

    The delivery of drugs, antigens, and imaging agents benefits from using nanotechnology-based carriers. The successful translation of nanoformulations to the clinic involves thorough assessment of their safety profiles, which, among other end-points, includes evaluation of immunotoxicity. The past decade of research focusing on nanoparticle interaction with the immune system has been fruitful in terms of understanding the basics of nanoparticle immunocompatibility, developing a bioanalytical infrastructure to screen for nanoparticle-mediated immune reactions, beginning to uncover the mechanisms of nanoparticle immunotoxicity, and utilizing current knowledge about the structure-activity relationship between nanoparticles' physicochemical properties and their effects on the immune system to guide safe drug delivery. In the present review, we focus on the most prominent pieces of the nanoparticle-immune system puzzle and discuss the achievements, disappointments, and lessons learned over the past 15years of research on the immunotoxicity of engineered nanomaterials. Copyright © 2016 Elsevier Inc. All rights reserved.

  18. Patterns and processes in the California Current System

    Science.gov (United States)

    Checkley, David M., Jr.; Barth, John A.

    2009-12-01

    The California Current System (CCS) is forced by the distribution of atmospheric pressure and associated winds in relation to the west coast of North America. In this paper, we begin with a simplified case of winds and a linear coast, then consider variability characteristic of the CCS, and conclude by considering future change. The CCS extends from the North Pacific Current (∼50°N) to off Baja California, Mexico (∼15-25°N) with a major discontinuity at Point Conception (34.5°N). Variation in atmospheric pressure affects winds and thus upwelling. Coastal, wind-driven upwelling results in nutrification and biological production and a southward coastal jet. Offshore, curl-driven upwelling results in a spatially large, productive habitat. The California Current flows equatorward and derives from the North Pacific Current and the coastal jet. Dominant modes of spatial and temporal variability in physical processes and biological responses are discussed. High surface production results in deep and bottom waters depleted in oxygen and enriched in carbon dioxide. Fishing has depleted demersal stocks more than pelagic stocks, and marine mammals, including whales, are recovering. Krill, squid, and micronekton are poorly known and merit study. Future climate change will differ from past change and thus prediction of the CCS requires an understanding of its dynamics. Of particular concern are changes in winds, stratification, and ocean chemistry.

  19. Eddy Current Thermography: System Development and Its Application in NDT

    International Nuclear Information System (INIS)

    Nurliyana Shamimie Rusli; Ilham Mukriz Zainal Abidin; Sidek, H.A.A.

    2015-01-01

    Eddy Current Thermography (ECT) is an integrative technique which combines eddy current and thermographic NDT in order to provide an efficient method for defect detection. The technique is applicable to electrically conductive material and has the ability to detect surface and subsurface defect. ECT is a non-contact technique; has the ability to provide instantaneous response and high scanning speed that makes it reliable for defect detection and assessment. The technique combines electromagnetic excitation of the work-piece via a coil carrying current, heating of the material by induction and inspection by transient infrared thermography. In this paper, the development of ECT system is detailed, including coil design for global and local heating of samples, and optimisation of excitation parameters (frequency, power, heating duration etc). Results from 3D FEM simulation and experimental investigations are also presented to provide the overview of underlying phenomena and application of ECT. The work demonstrates the effectiveness of the developed ECT system and technique in defect detection and assessment. (author)

  20. Modeling and control of the output current of a Reformed Methanol Fuel Cell system

    DEFF Research Database (Denmark)

    Justesen, Kristian Kjær; Andreasen, Søren Juhl; Pasupathi, Sivakumar

    2015-01-01

    In this work, a dynamic Matlab SIMULINK model of the relationship between the fuel cell current set point of a Reformed Methanol Fuel Cell system and the output current of the system is developed. The model contains an estimated fuel cell model, based on a polarization curve and assumed first order...... dynamics, as well as a battery model based on an equivalent circuit model and a balance of plant power consumption model. The models are tuned with experimental data and verified using a verification data set. The model is used to develop an output current controller which can control the charge current...... of the battery. The controller is a PI controller with feedforward and anti-windup. The performance of the controller is tested and verified on the physical system....

  1. Realisation and instrumentation of high current power station for superconducting cables testing

    International Nuclear Information System (INIS)

    Regnaud, S.

    2000-05-01

    This report deals with the designing of a high current station able to test electric properties of superconductors. This test station will be used for testing the superconducting wires of large hadron collider detectors in CERN. The high current test station will have to generate high intensity continuous current in a magnetic field of 0 to 5 tesla and in temperature conditions of 4.2 K. The length of wire samples submitted to the uniform magnetic field is 300 mm and the installation is fitted with equipment able to measure the magnetic field perpendicular to either faces of the wire. The peculiarity of this station is to use a superconducting transformer in order to generate the high current. The first part of this work recalls important notions concerning superconductivity. The second part presents the high current station by describing the superconducting transformer and the sample-holder. We have studied the designing of a transformer able to yield a secondary current whose intensity reaches 100 kA, such intensity generates powerful electromagnetic forces (566 kN/m) in case of defect, so the sample-holder has to be carefully design to bear them. The third part presents the cryogenic component of the station, the instrumentation of the sample-holder and the method used to measure secondary currents. In the last part we present the performance of a prototype transformer, this prototype is able to deliver a 22 kA secondary current for a 160 A primary current, the uncertainty on the measured value of the secondary current is about 3%

  2. Preoperational test report, recirculation condenser cooling systems

    International Nuclear Information System (INIS)

    Clifton, F.T.

    1997-01-01

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System

  3. Preoperational test report, recirculation condenser cooling systems

    Energy Technology Data Exchange (ETDEWEB)

    Clifton, F.T.

    1997-11-04

    This represents a preoperational test report for Recirculation Condenser Systems, Project W-030. Project W-030 provides a ventilation upgrade for the four Aging Waste Facility tanks. The four system provide condenser cooling water for vapor space cooling of tanks AY1O1, AY102, AZ1O1, AZ102. Each system consists of a valved piping loop, a pair of redundant recirculation pumps, a closed-loop evaporative cooling tower, and supporting instrumentation; equipment is located outside the farm on concrete slabs. Piping is routed to the each ventilation condenser inside the farm via below-grade concrete trenches. The tests verify correct system operation and correct indications displayed by the central Monitor and Control System.

  4. GES [Ground Engineering System] test site preparation

    International Nuclear Information System (INIS)

    Cox, C.M.; Mahaffey, M.K.; Miller, W.C.; Schade, A.R.; Toyoda, K.G.

    1987-10-01

    Activities are under way at Hanford to convert the 309 containment building and its associated service wing to a nuclear test facility for the Ground Engineering System (GES) test. Conceptual design is about 80% complete, encompassing facility modifications, a secondary heat transport system, a large vacuum system, a test article cell and handing system, control and data handling systems, and safety andl auxiliary systems. The design makes extensive use of existing equipment to minimize technical risk and cost. Refurbishment of this equipment is 25% complete. Cleanout of some 1000 m 3 of equipment from the earlier reactor test in the facility is 85% complete. An Environmental Assessment was prepared and revised to incorporate Department of Energy (DOE) comments. It is now in the DOE approval chain, where a Finding of No Significant Impact is expected. During the next year, definite design will be well advanced, long-lead procurements will be initiated, construction planning will be completed, an operator training plan will be prepared, and the site (preliminary) safety analysis report will be drafted

  5. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  6. Seismic proving test of BWR primary loop recirculation system

    International Nuclear Information System (INIS)

    Sato, H.; Shigeta, M.; Karasawa, Y.

    1987-01-01

    The seismic proving test of BWR Primary Loop Recirculation system is the second test to use the large-scale, high-performance vibration table of Tadotsu Engineering Laboratory. The purpose of this test is to prove the seismic reliability of the primary loop recirculation system (PLR), one of the most important safety components in the BWR nuclear plants, and also to confirm the adequacy of seismic analysis method used in the current seismic design. To achieve the purpose, the test was conducted under conditions and scale as near as possible to actual systems. The strength proving test was carried out with the test model mounted on the vibration table in consideration of basic design earthquake ground motions and other conditions to confirm the soundness of structure and the strength against earthquakes. Detailed analysis and analytic evaluation of the data obtained from the test was conducted to confirm the adequacy of the seismic analysis method and earthquake response analysis method used in the current seismic design. Then, on the basis of the results obtained, the seismic safety and reliability of BWR primary loop recirculation of the actual plants was fully evaluated

  7. Acquisition system testing with superfluid helium

    International Nuclear Information System (INIS)

    Anderson, J.E.; Fester, D.A.; DiPirro, M.J.

    1988-01-01

    NASA is evaluating both a thermomechanical pump and centrifugal pump for the SHOOT experiment using capillary fluid acquisition systems. Tests were conducted for these systems with superfluid helium under adverse operating conditions. Minus one-g outflow tests were run in conjunction with the thermomechanical pump. Both fine mesh screen and porous sponges were tested. A screen acquisition device was also tested with the low-NPSH centrifugal pump. Results to date show that the screen and sponge are capable of supplying superfluid helium to the thermomechanical pump inlet against a one-g head up to four cm. This is more than sufficient for the SHOOT application. Results with the sponge were reproducible while those with the screen could not always be repeated

  8. Considerations on an automatic computed tomography tube current modulation system

    International Nuclear Information System (INIS)

    Moro, L.; Panizza, D.; D'Ambrosio, D.; Carne, I.

    2013-01-01

    The scope of this study was to evaluate the effects on radiation output and image noise varying the acquisition parameters with an automatic tube current modulation (ATCM) system in computed tomography (CT). Chest CT examinations of an anthropomorphic phantom were acquired using a GE LightSpeed VCT 64-slice tomograph. Acquisitions were performed using different pitch, slice thickness and noise index (NI) values and varying the orientation of the scanned projection radiograph (SPR). The radiation output was determined by the CT dose index (CTDI vol ). Image noise was evaluated measuring the standard deviation of CT numbers in several regions of interest. The radiation output was lower if the SPR was acquired in the anterior-posterior projection. The radiation dose with the posterior-anterior SPR was higher, because the divergence of the X-ray beam magnifies the anatomical structures closest to the tube, especially the spinal column, and this leads the ATCM system to estimate higher patient attenuation values and, therefore, to select higher tube current values. The NI was inversely proportional to the square root of the CTDI vol and, with fixed NI, the CTDI vol increased as the slice thickness decreased. This study suggests some important issues to use the GE ATCM system efficiently. (authors)

  9. System design description for the whole element furnace testing system

    International Nuclear Information System (INIS)

    Ritter, G.A.; Marschman, S.C.; MacFarlan, P.J.; King, D.A.

    1998-05-01

    This document provides a detailed description of the Hanford Spent Nuclear Fuel (SNF) Whole Element Furnace Testing System located in the Postirradiation Testing Laboratory G-Cell (327 Building). Equipment specifications, system schematics, general operating modes, maintenance and calibration requirements, and other supporting information are provided in this document. This system was developed for performing cold vacuum drying and hot vacuum drying testing of whole N-Reactor fuel elements, which were sampled from the 105-K East and K West Basins. The proposed drying processes are intended to allow dry storage of the SNF for long periods of time. The furnace testing system is used to evaluate these processes by simulating drying sequences with a single fuel element and measuring key system parameters such as internal pressures, temperatures, moisture levels, and off-gas composition

  10. Study on signal processing in Eddy current testing for defects in spline gear

    International Nuclear Information System (INIS)

    Lee, Jae Ho; Park, Tae Sug; Park, Ik Keun

    2016-01-01

    Eddy current testing (ECT) is commonly applied for the inspection of automated production lines of metallic products, because it has a high inspection speed and a reasonable price. When ECT is applied for the inspection of a metallic object having an uneven target surface, such as the spline gear of a spline shaft, it is difficult to distinguish between the original signal obtained from the sensor and the signal generated by a defect because of the relatively large surface signals having similar frequency distributions. To facilitate the detection of defect signals from the spline gear, implementation of high-order filters is essential, so that the fault signals can be distinguished from the surrounding noise signals, and simultaneously, the pass-band of the filter can be adjusted according to the status of each production line and the object to be inspected. We will examine the infinite impulse filters (IIR filters) available for implementing an advanced filter for ECT, and attempt to detect the flaw signals through optimization of system design parameters for detecting the signals at the system level

  11. Current configuration and performance of the TFTR computer system

    International Nuclear Information System (INIS)

    Sauthoff, N.R.; Barnes, D.J.; Daniels, R.; Davis, S.; Reid, A.; Snyder, T.; Oliaro, G.; Stark, W.; Thompson, J.R. Jr.

    1986-01-01

    Developments in the TFTR (Tokamak Fusion Test Reactor) computer support system since its startup phases are described. Early emphasis on tokamak process control have been augmented by improved physics data handling, both on-line and off-line. Data acquisition volume and rate have been increased, and data is transmitted automatically to a new VAX-based off-line data reduction system. The number of interface points has increased dramatically, as has the number of man-machine interfaces. The graphics system performance has been accelerated by the introduction of parallelism, and new features such as shadowing and device independence have been added. To support multicycle operation for neutral beam conditioning and independence, the program control system has been generalized. A status and alarm system, including calculated variables, is in the installation phase. System reliability has been enhanced by both the redesign of weaker components and installation of a system status monitor. Development productivity has been enhanced by the addition of tools

  12. Seasonality of the Mindanao Current/Undercurrent System

    Science.gov (United States)

    Ren, Qiuping; Li, Yuanlong; Wang, Fan; Song, Lina; Liu, Chuanyu; Zhai, Fangguo

    2018-02-01

    Seasonality of the Mindanao Current (MC)/Undercurrent (MUC) system is investigated using moored acoustic Doppler current profiler (ADCP) measurements off Mindanao (8°N, 127.05°E) and ocean model simulations. The mooring observation during December 2010 to August 2014 revealed that the surface-layer MC between 50-150 m is dominated by annual-period variation and tends to be stronger in spring (boreal) and weaker in fall. Prominent semiannual variations were detected below 150 m. The lower MC between 150 and 400 m is stronger in spring and fall and weaker in summer and winter, while the northward MUC below 400 m emerges in summer and winter and disappears in spring and fall. In-phase and out-of-phase current anomalies above and below 150 m were observed alternatively. These variations are faithfully reproduced by an eddy-resolving ocean model simulation (OFES). Further analysis demonstrates that seasonal variation of the MC is a component of large-scale upper-ocean circulation gyre, while current variations in the MUC layer are confined near the western boundary and featured by shorter-scale (200-400 km) structures. Most of the MC variations and approximately half of the MUC variations can be explained by the first and second baroclinic modes and caused by local wind forcing of the western Pacific. Semiannual surface wind variability and superimposition of the two baroclinic modes jointly give rise to the enhanced subsurface semiannual variations. The pronounced mesoscale eddy variability in the MUC layer may also contribute to the seasonality of the MUC through eddy-current interaction.

  13. Light-emitting device test systems

    Science.gov (United States)

    McCord, Mark; Brodie, Alan; George, James; Guan, Yu; Nyffenegger, Ralph

    2018-01-23

    Light-emitting devices, such as LEDs, are tested using a photometric unit. The photometric unit, which may be an integrating sphere, can measure flux, color, or other properties of the devices. The photometric unit may have a single port or both an inlet and outlet. Light loss through the port, inlet, or outlet can be reduced or calibrated for. These testing systems can provide increased reliability, improved throughput, and/or improved measurement accuracy.

  14. Current ethical and legal issues in health-related direct-to-consumer genetic testing.

    Science.gov (United States)

    Niemiec, Emilia; Kalokairinou, Louiza; Howard, Heidi Carmen

    2017-09-01

    A variety of health-related genetic testing is currently advertized directly to consumers. This article provides a timely overview of direct-to-consumer genetic testing (DTC GT) and salient ethical issues, as well as an analysis of the impact of the recently adopted regulation on in vitro diagnostic medical devices on DTC GT. DTC GT companies currently employ new testing approaches, report on a wide spectrum of conditions and target new groups of consumers. Such activities raise ethical issues including the questionable analytic and clinical validity of tests, the adequacy of informed consent, potentially misleading advertizing, testing in children, research uses and commercialization of genomic data. The recently adopted regulation on in vitro diagnostic medical devices may limit the offers of predisposition DTC GT in the EU market.

  15. Neurovirulence safety testing of mumps vaccines--historical perspective and current status.

    Science.gov (United States)

    Rubin, S A; Afzal, M A

    2011-04-05

    Many live, attenuated viral vaccines are derived from wild type viruses with known neurovirulent properties. To assure the absence of residual neurotoxicity, pre-clinical neurovirulence safety testing of candidate vaccines is performed. For mumps virus, a highly neurotropic virus, neurovirulence safety testing is performed in monkeys. However, laboratory studies suggest an inability of this test to correctly discern among virus strains of varying neurovirulence potential in man, and, further, some vaccines found to be neuroattenuated in monkeys were later found to be neurovirulent in humans when administered in large numbers. Over the past decade, concerted efforts have been made to replace monkey-based neurovirulence safety testing with more informative, alternative methods. This review summarizes the current status of mumps vaccine neurovirulence safety testing and insights into models currently approved and those under development. Published by Elsevier Ltd.

  16. Tritium Systems Test Assembly: design for major device fabrication review

    International Nuclear Information System (INIS)

    Anderson, J.L.; Sherman, R.H.

    1977-06-01

    This document has been prepared for the Major Device Fabrication Review for the Tritium Systems Test Assembly (TSTA). The TSTA is dedicated to the development, demonstration, and interfacing of technologies related to the deuterium-tritium fuel cycle for fusion reactor systems. The principal objectives for TSTA are: (a) demonstrate the fuel cycle for fusion reactor systems; (b) develop test and qualify equipment for tritium service in the fusion program; (c) develop and test environmental and personnel protective systems; (d) evaluate long-term reliability of components; (e) demonstrate long-term safe handling of tritium with no major releases or incidents; and (f) investigate and evaluate the response of the fuel cycle and environmental packages to normal, off-normal, and emergency situations. This document presents the current status of a conceptual design and cost estimate for TSTA. The total cost to design, construct, and operate TSTA through FY-1981 is estimated to be approximately $12.2 M

  17. DOE LeRC photovoltaic systems test facility

    Science.gov (United States)

    Cull, R. C.; Forestieri, A. F.

    1978-01-01

    The facility was designed and built and is being operated as a national facility to serve the needs of the entire DOE National Photovoltaic Program. The object of the facility is to provide a place where photovoltaic systems may be assembled and electrically configured, without specific physical configuration, for operation and testing to evaluate their performance and characteristics. The facility as a breadboard system allows investigation of operational characteristics and checkout of components, subsystems and systems before they are mounted in field experiments or demonstrations. The facility as currently configured consist of 10 kW of solar arrays built from modules, two inverter test stations, a battery storage system, interface with local load and the utility grid, and instrumentation and control necessary to make a flexible operating facility. Expansion to 30 kW is planned for 1978. Test results and operating experience are summaried to show the variety of work that can be done with this facility.

  18. An evaluation of current EIA system in Pakistan

    International Nuclear Information System (INIS)

    Shah, I.A.; Romano, R.R.

    2004-01-01

    The challenge of reducing poverty and increasing economic growth has often led Pakistan to overlook environmental sustainability. Consequently, Pakistan, is suffering from severe environmental problems. This has spurred an increasing demand for and effective Environmental Impact Assessment (EIA) System with environmental management tools and techniques that can help the country to adequately diagnose their risks and suggest mitigation options. In the past few years Pakistan has begun implementing EIA' s as a preventive tool. However, given the judiciary, institutional and structural predicament, the outcome of the EIA process has resulted in great disparities. Given the growing regional environmental problems it is now a priority to seek an effective EIA systems, principles, and procedures in the country. This paper seeks to distinguish the Pakistan EIA strengths and weaknesses; it also focuses on identifying common positive and negative characteristics of the Pakistan EIA system. Furthermore, differences between the interested parties of the EIA system in the country were evaluated via a survey to ensure a good understanding of the factors of a comprehensive and effective EIA system. Analytical comparisons were made among the different interested parties of the EIA system in Pakistan. Statistical methods were used to analyze the data received and recommendations were made based on the outcome of the data results. These results will assist: (i) Pakistan to improve its EIA system (ii) other South Asian countries which may have a similar EIA systems in developing policy, planning and reforms and (iii) International organizations that work or invest in the region to enhance the attainment of environ- mental protection objectives on a broader, more cost effective, and realistic scale than current practices. (author)

  19. Eddy current system for inspection of train hollow axles

    Energy Technology Data Exchange (ETDEWEB)

    Chady, Tomasz; Psuj, Grzegorz; Sikora, Ryszard; Kowalczyk, Jacek; Spychalski, Ireneusz [Department of Electrical and Computer Engineering, Faculty of Electrical Engineering, West Pomeranian University of Technology, Szczecin (Poland)

    2014-02-18

    The structural integrity of wheelsets used in rolling stock is of great importance to the safety. In this paper, electromagnetic system with an eddy current transducer suitable for the inspection of hollow axles have been presented. The transducer was developed to detect surface braking defects having depth not smaller than 0.5 mm. Ultrasound technique can be utilized to inspect the whole axle, but it is not sufficiently sensitive to shallow defects located close to the surface. Therefore, the electromagnetic technique is proposed to detect surface breaking cracks that cannot be detected by ultrasonic technique.

  20. Current approach for urinary system stone disease in pregnant women

    Directory of Open Access Journals (Sweden)

    Orcun Celik

    2016-01-01

    Full Text Available Urinary system stones can be classified according to size, location, X-ray characteristics, aetiology of formation, composition, and risk of recurrence. Especially urolithiasis during pregnancy is a diagnostic and therapeutic challenge. In most cases, it becomes symptomatic in the second or third trimester. Diagnostic options in pregnant women are limited due to the possible teratogenic, carcinogenic, and mutagenic risk of foetal radiation exposure. Clinical management of a pregnant urolithiasis patient is complex and demands close collaboration between patient, obstetrician and urologist. We would like to review current diagnosis and treatment modalities of stone disease of pregnant woman.

  1. W-026, acceptance test report manipulator system

    International Nuclear Information System (INIS)

    Watson, T.L.

    1997-01-01

    The purpose of the WRAP Manipulator System Acceptance Test Plan (ATP) is to verify that the 4 glovebox sets of WRAP manipulator components, including rail/carriage, slave arm, master controller and auxiliary equipment, meets the requirements of the functional segments of 14590 specification. The demonstration of performance elements of the ATP are performed as a part of the Assembly specifications. Manipulator integration is integrated in the performance testing of the gloveboxes. Each requirement of the Assembly specification will be carried out in conjunction with glovebox performance tests

  2. Spaceport Command and Control System Automation Testing

    Science.gov (United States)

    Plano, Tom

    2017-01-01

    The goal of automated testing is to create and maintain a cohesive infrastructure of robust tests that could be run independently on a software package in its entirety. To that end, the Spaceport Command and Control System (SCCS) project at the National Aeronautics and Space Administration's (NASA) Kennedy Space Center (KSC) has brought in a large group of interns to work side-by-side with full time employees to do just this work. Thus, our job is to implement the tests that will put SCCS through its paces.

  3. Alternative (non-animal) methods for cosmetics testing: current status and future prospects-2010.

    Science.gov (United States)

    Adler, Sarah; Basketter, David; Creton, Stuart; Pelkonen, Olavi; van Benthem, Jan; Zuang, Valérie; Andersen, Klaus Ejner; Angers-Loustau, Alexandre; Aptula, Aynur; Bal-Price, Anna; Benfenati, Emilio; Bernauer, Ulrike; Bessems, Jos; Bois, Frederic Y; Boobis, Alan; Brandon, Esther; Bremer, Susanne; Broschard, Thomas; Casati, Silvia; Coecke, Sandra; Corvi, Raffaella; Cronin, Mark; Daston, George; Dekant, Wolfgang; Felter, Susan; Grignard, Elise; Gundert-Remy, Ursula; Heinonen, Tuula; Kimber, Ian; Kleinjans, Jos; Komulainen, Hannu; Kreiling, Reinhard; Kreysa, Joachim; Leite, Sofia Batista; Loizou, George; Maxwell, Gavin; Mazzatorta, Paolo; Munn, Sharon; Pfuhler, Stefan; Phrakonkham, Pascal; Piersma, Aldert; Poth, Albrecht; Prieto, Pilar; Repetto, Guillermo; Rogiers, Vera; Schoeters, Greet; Schwarz, Michael; Serafimova, Rositsa; Tähti, Hanna; Testai, Emanuela; van Delft, Joost; van Loveren, Henk; Vinken, Mathieu; Worth, Andrew; Zaldivar, José-Manuel

    2011-05-01

    The 7th amendment to the EU Cosmetics Directive prohibits to put animal-tested cosmetics on the market in Europe after 2013. In that context, the European Commission invited stakeholder bodies (industry, non-governmental organisations, EU Member States, and the Commission's Scientific Committee on Consumer Safety) to identify scientific experts in five toxicological areas, i.e. toxicokinetics, repeated dose toxicity, carcinogenicity, skin sensitisation, and reproductive toxicity for which the Directive foresees that the 2013 deadline could be further extended in case alternative and validated methods would not be available in time. The selected experts were asked to analyse the status and prospects of alternative methods and to provide a scientifically sound estimate of the time necessary to achieve full replacement of animal testing. In summary, the experts confirmed that it will take at least another 7-9 years for the replacement of the current in vivo animal tests used for the safety assessment of cosmetic ingredients for skin sensitisation. However, the experts were also of the opinion that alternative methods may be able to give hazard information, i.e. to differentiate between sensitisers and non-sensitisers, ahead of 2017. This would, however, not provide the complete picture of what is a safe exposure because the relative potency of a sensitiser would not be known. For toxicokinetics, the timeframe was 5-7 years to develop the models still lacking to predict lung absorption and renal/biliary excretion, and even longer to integrate the methods to fully replace the animal toxicokinetic models. For the systemic toxicological endpoints of repeated dose toxicity, carcinogenicity and reproductive toxicity, the time horizon for full replacement could not be estimated.

  4. Comments on Current Space Systems Observing the Climate

    Science.gov (United States)

    Fisk, L. A.

    2016-07-01

    The Global Climate Observing System (GCOS), which was established in 1992, has been effective in specifying the observations needed for climate studies, and advocating that these observations be made. As a result, there are essential climate variables being observed, particularly from space, and these have formed the basis for our ever-improving models of how the Earth system functions and the human impact on it. We cannot conclude, however, that the current observing system in space is adequate. Climate change is accelerating, and we need to ensure that our observations capture, with completeness and with proper resolution and cadence, the most important changes. Perhaps of most significance, we need to use observations from space to guide the mitigation and adaptation strategies on which at last our civilization seems prepared to embark. And we need to use our observations to educate particularly policy makers on the reality of climate change, so that none deny the need to act. COSPAR is determined to play its part in highlighting the need to strengthen the climate observing system and notably its research component. This is being accomplished through events like the present roundtable, through the work of its Scientific Commission A, its Task Group on GEO (where COSPAR is serving as a member of its Program Board), and by promoting among space agencies and policy-makers the recently released scientific roadmap on Integrated Earth System Science for the period 2016-2025.

  5. Mini Solar and Sea Current Power Generation System

    Science.gov (United States)

    Almenhali, Abdulrahman; Alshamsi, Hatem; Aljunaibi, Yaser; Almussabi, Dheyab; Alshehhi, Ahmed; Hilal, Hassan Bu

    2017-07-01

    The power demand in United Arab Emirates is increased so that there is a consistent power cut in our region. This is because of high power consumption by factories and also due to less availability of conventional energy resources. Electricity is most needed facility for the human being. All the conventional energy resources are depleting day by day. So we have to shift from conventional to non-conventional energy resources. In this the combination of two energy resources is takes place i.e. wind and solar energy. This process reviles the sustainable energy resources without damaging the nature. We can give uninterrupted power by using hybrid energy system. Basically this system involves the integration of two energy system that will give continuous power. Solar panels are used for converting solar energy and wind turbines are used for converting wind energy into electricity. This electrical power can utilize for various purpose. Generation of electricity will be takes place at affordable cost. This paper deals with the generation of electricity by using two sources combine which leads to generate electricity with affordable cost without damaging the nature balance. The purpose of this project was to design a portable and low cost power system that combines both sea current electric turbine and solar electric technologies. This system will be designed in efforts to develop a power solution for remote locations or use it as another source of green power.

  6. Development and Testing of High Current Hollow Cathodes for High Power Hall Thrusters

    Science.gov (United States)

    Kamhawi, Hani; Van Noord, Jonathan

    2012-01-01

    NASA's Office of the Chief Technologist In-Space Propulsion project is sponsoring the testing and development of high power Hall thrusters for implementation in NASA missions. As part of the project, NASA Glenn Research Center is developing and testing new high current hollow cathode assemblies that can meet and exceed the required discharge current and life-time requirements of high power Hall thrusters. This paper presents test results of three high current hollow cathode configurations. Test results indicated that two novel emitter configurations were able to attain lower peak emitter temperatures compared to state-of-the-art emitter configurations. One hollow cathode configuration attained a cathode orifice plate tip temperature of 1132 degC at a discharge current of 100 A. More specifically, test and analysis results indicated that a novel emitter configuration had minimal temperature gradient along its length. Future work will include cathode wear tests, and internal emitter temperature and plasma properties measurements along with detailed physics based modeling.

  7. EDDYMULT: a computing system for solving eddy current problems in a multi-torus system

    International Nuclear Information System (INIS)

    Nakamura, Yukiharu; Ozeki, Takahisa

    1989-03-01

    A new computing system EDDYMULT based on the finite element circuit method has been developed to solve actual eddy current problems in a multi-torus system, which consists of many torus-conductors and various kinds of axisymmetric poloidal field coils. The EDDYMULT computing system can deal three-dimensionally with the modal decomposition of eddy current in a multi-torus system, the transient phenomena of eddy current distributions and the resultant magnetic field. Therefore, users can apply the computing system to the solution of the eddy current problems in a tokamak fusion device, such as the design of poloidal field coil power supplies, the mechanical stress design of the intensive electromagnetic loading on device components and the control analysis of plasma position. The present report gives a detailed description of the EDDYMULT system as an user's manual: 1) theory, 2) structure of the code system, 3) input description, 4) problem restrictions, 5) description of the subroutines, etc. (author)

  8. Data acquisition and test system software

    International Nuclear Information System (INIS)

    Bourgeois, N.A. Jr.

    1979-03-01

    Sandia Laboratories has been assigned the task by the Base and Installation Security Systems (BISS) Program Office to develop various aspects of perimeter security systems. One part of this effort involves the development of advanced signal processing techniques to reduce the false and nuisance alarms from sensor systems while improving the probability of intrusion detection. The need existed for both data acquisition hardware and software. Also, the hardware is used to implement and test the signal processing algorithms in real time. The hardware developed for this signal processing task is the Data Acquisition and Test System (DATS). The programs developed for use on DATS are described. The descriptions are taken directly from the documentation included within the source programs themselves

  9. Results from the STAR TPC system test

    International Nuclear Information System (INIS)

    Betts, W.

    1996-01-01

    A system test of various components of the Solenoidal Tracker at RHIC (STAR) detector, operating in concern, has recently come on-line. Communication between a major sub-detector, a sector of the Time Projection Chamber (TPC), and the trigger, data acquisition and slow controls systems has been established, enabling data from cosmic ray muons to be collected. First results from an analysis of the TPC data are presented. These include measurements of system noise, electronic parameters such as amplifier gains and pedestal values, and tracking resolution for cosmic ray muons and laser induced ionization tracks. A discussion on the experience gained in integrating the different components for the system test is also given

  10. A new on-line leakage current monitoring system of ZnO surge arresters

    International Nuclear Information System (INIS)

    Lee, Bok-Hee; Kang, Sung-Man

    2005-01-01

    This paper presents a new on-line leakage current monitoring system of zinc oxide (ZnO) surge arresters. To effectively diagnose the deterioration of ZnO surge arresters, a new algorithm and on-line leakage current detection device, which uses the time-delay addition method, for discriminating the resistive and capacitive currents was developed to use in the aging test and durability evaluation for ZnO arrester blocks. A computer-based measurement system of the resistive leakage current, the on-line monitoring device can detect accurately the leakage currents flowing through ZnO surge arresters for power frequency ac applied voltages. The proposed on-line leakage current monitoring device of ZnO surge arresters is more highly sensitive and gives more linear response than the existing devices using the detection method of the third harmonic leakage currents. Therefore, the proposed leakage current monitoring device can be useful for predicting the defects and performance deterioration of ZnO surge arresters in power system applications

  11. Food reward system: current perspectives and future research needs.

    Science.gov (United States)

    Alonso-Alonso, Miguel; Woods, Stephen C; Pelchat, Marcia; Grigson, Patricia Sue; Stice, Eric; Farooqi, Sadaf; Khoo, Chor San; Mattes, Richard D; Beauchamp, Gary K

    2015-05-01

    This article reviews current research and cross-disciplinary perspectives on the neuroscience of food reward in animals and humans, examines the scientific hypothesis of food addiction, discusses methodological and terminology challenges, and identifies knowledge gaps and future research needs. Topics addressed herein include the role of reward and hedonic aspects in the regulation of food intake, neuroanatomy and neurobiology of the reward system in animals and humans, responsivity of the brain reward system to palatable foods and drugs, translation of craving versus addiction, and cognitive control of food reward. The content is based on a workshop held in 2013 by the North American Branch of the International Life Sciences Institute. © The Author(s) 2015. Published by Oxford University Press on behalf of the International Life Sciences Institute.

  12. Strengths and Weaknesses of the Current Dental Hygiene Educational System.

    Science.gov (United States)

    Theile, Cheryl Westphal

    2017-09-01

    The state of the dental hygiene educational system in the United States is evolving. The numbers of programs, extent of curricula, and diversity of students, faculty, and practice settings vary significantly across the country. New trends in workforce utilization and delivery models are challenging current educational foundations and mandating an interprofessional approach to both the education and practice of dental hygienists. This article presents an overview of the current state of dental hygiene education to create a baseline for discussion of desired educational models for 2040. The strengths and weaknesses are defined to motivate change. Limitations of the current two-year associate degree are emphasized, along with the need to add expanded content and development of new skills. The developing non-traditional practice settings bring both a challenge to dental hygiene education and a promise of increasing potential in primary care interprofessional settings for the 21 st century. This article was written as part of the project "Advancing Dental Education in the 21 st Century."

  13. Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test

    Science.gov (United States)

    Huang, Wensheng; Kamhawi, Hani; Shastry, Rohit

    2012-01-01

    There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.

  14. Advisory expert system for test rig operator

    International Nuclear Information System (INIS)

    Zielczynski, P.

    1994-01-01

    The advisory expert system MAESTRO (Modular Advisory Expert System for Test Rig Operator) has been designed to guide the operator of large experimental installation during start-up, steady state and shut down. The installation is located in the research reactor MARIA in the Institute of Atomic Energy in Swierk, Poland. The system acquires and analyses on line signals from installation and performs two tasks in real time: leading the operator and monitoring of the installation (including signal validation). Systems tasks, architecture and knowledge representation concepts are described. The system is based on expert systems techniques what makes in phases of continuous change of process parameters and it has been achieved by special knowledge representation allowing its dynamical modification. (author). 147 refs, 42 figs, 5 tab

  15. Prototype Engineered Barrier System Field Test (PEBSFT)

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Buscheck, T.; Carlson, R.; Daily, W.; Lee, K.; Lin, Wunan; Mao, Nai-hsien; Ueng, Tzou-Shin; Wang, H.; Watwood, D.

    1991-08-01

    This final report represents a summary of data and interpretations obtained from the Prototype Engineered Barrier System Field Test (PEBSFT) performed in G-Tunnel within the Nevada Test Site. The PEBSFT was conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for future field tests that will be conducted in the Exploratory Studies Facilities (ESF) at Yucca Mountain. The primary objective of the test was to provide a basis for determining whether tests planned for the ESF have the potential to be successful. Chapter 1 on high frequency electromagnetic tomography discusses the rock mass electromagnetic permittivity and attenuation rate changes that were measured to characterize the water distribution in the near field of a simulated waste container. The data are used to obtain quantitative estimates of how the moisture content in the rock mass changes during heating and to infer properties of the spatial variability of water distribution, leading to conclusions about the role of fractures in the system. Chapter 2 discusses the changes in rock moisture content detected by the neutron logging probe. Chapter 3 permeability tests discusses the characterization of the in-situ permeability of the fractured tuff around the borehole. The air permeability testing apparatus, the testing procedures, and the data analysis are presented. Chapter 4 describes the moisture collection system installed in the heater borehole to trap and measure the moisture volumes. Chapter 5 describes relative humidity measurements made with the thermocouple psychrometer and capacitance sensors. Chapter 6 discusses gas pressure measurements in the G-Tunnel, addressing the calibration and installation of piezoresistive-gaged transducers. Chapter 7 describes the calibration and installation of thermocouples for temperature measurements. Chapter 8 discusses the results of the PEBSFT

  16. High temperature superconducting current lead test facility with heat pipe intercepts

    International Nuclear Information System (INIS)

    Blumenfeld, P.E.; Prenger, C.; Roth, E.W.; Stewart, J.A.

    1998-01-01

    A high temperature superconducting (HTS) current lead test facility using heat pipe thermal intercepts is under development at the Superconducting Technology Center at Los Alamos National Laboratory. The facility can be configured for tests at currents up to 1,000 A. Mechanical cryocoolers provide refrigeration to the leads. Electrical isolation is maintained by intercepting thermal energy from the leads through cryogenic heat pipes. HST lead warm end temperature is variable from 65 K to over 90 K by controlling heat pipe evaporator temperature. Cold end temperature is variable up to 30 K. Performance predictions in terms of heat pipe evaporator temperature as a function of lead current are presented for the initial facility configuration, which supports testing up to 200 A. Measurements are to include temperature and voltage gradient in the conventional and HTS lead sections, temperature and heat transfer rate in the heat pipes. as well as optimum and off-optimum performance of the conventional lead sections

  17. Tritium Systems Test Facility. Volume I

    International Nuclear Information System (INIS)

    Anderson, G.W.; Battleson, K.W.; Bauer, W.

    1976-10-01

    Sandia Laboratories proposes to build and operate a Tritium Systems Test Facility (TSTF) in its newly completed Tritium Research Laboratory at Livermore, California (see frontispiece). The facility will demonstrate at a scale factor of 1:200 the tritium fuel cycle systems for an Experimental Power Reactor (EPR). This scale for each of the TSTF subsystems--torus, pumping system, fuel purifier, isotope separator, and tritium store--will allow confident extrapolation to EPR dimensions. Coolant loop and reactor hall cleanup facilities are also reproduced, but to different scales. It is believed that all critical details of an EPR tritium system will be simulated correctly in the facility. Tritium systems necessary for interim devices such as the Ignition Test Reactor (ITR) or The Next Step (TNS) can also be simulated in TSTF at other scale values. The active tritium system will be completely enclosed in an inert atmosphere glove box which will be connected to the existing Gas Purification System (GPS) of the Tritium Research Laboratory. In effect, the GPS will become the scaled environmental control system which otherwise would have to be built especially for the TSTF

  18. Supernatant treatment system design through testing

    International Nuclear Information System (INIS)

    Ploetz, D.K.; Leonard, I.M.

    1988-12-01

    The main purpose of the Supernatant Treatment System (STS) is to remove more than 99.9 percent of the radioactive cesium (Cs-137) from the high-level waste stored in tank 8D-2. Cesium removal is accomplished in the STS by processing the supernatant (liquid) portion of the high-level waste through three or four ion exchange columns filled with zeolite. After treatment in the STS, the decontaminated supernatant is processed as low-level waste and finally encapsulated in cement for eventual disposal. The Cs-137 removed from the waste and absorbed onto zeolite ion exchange material is temporarily stored in tank 8D-1 until it can be encapsulated in glass and disposed of as high-level waste. This report discusses construction and testing of the STS. Design of the STS was started in 1982 in parallel with the selection of the ion exchange material. The construction of this system was accomplished in five phase in parallel with completion of design to allow for faster completion of the project. The existing high-level waste storage tanks -- 8D-1, 8D-2, and 8D-3 -- required major renovations to permit transfer of the high-level waste from tank 8D-2 to tank 8D-1, to house the components that comprise the STS in tank 8D-1, and to store decontaminated wastes in tank 8D-3. Testing in the STS started before construction was complete and was accomplished by first testing components individually. Then the system was retested using simulated supernatant. Integrated testing of the whole Integrated Radwaste Treatment System (IRTS), which includes the STS, Liquid Waste Treatment System (LWTS), Cement Solidification System (CSS), and the Drum Cell, was also performed using simulated supernatant. Finally, slightly radioactive condensate water from tank 8D-1 was processed. After successfully completing this testing, the STS started operations with radioactive supernatant on May 23, 1988. 21 refs., 33 figs., 21 tabs

  19. Mediterranea Forecasting System: a focus on wave-current coupling

    Science.gov (United States)

    Clementi, Emanuela; Delrosso, Damiano; Pistoia, Jenny; Drudi, Massimiliano; Fratianni, Claudia; Grandi, Alessandro; Pinardi, Nadia; Oddo, Paolo; Tonani, Marina

    2016-04-01

    The Mediterranean Forecasting System (MFS) is a numerical ocean prediction system that produces analyses, reanalyses and short term forecasts for the entire Mediterranean Sea and its Atlantic Ocean adjacent areas. MFS became operational in the late 90's and has been developed and continuously improved in the framework of a series of EU and National funded programs and is now part of the Copernicus Marine Service. The MFS is composed by the hydrodynamic model NEMO (Nucleus for European Modelling of the Ocean) 2-way coupled with the third generation wave model WW3 (WaveWatchIII) implemented in the Mediterranean Sea with 1/16 horizontal resolution and forced by ECMWF atmospheric fields. The model solutions are corrected by the data assimilation system (3D variational scheme adapted to the oceanic assimilation problem) with a daily assimilation cycle, using a background error correlation matrix varying seasonally and in different sub-regions of the Mediterranean Sea. The focus of this work is to present the latest modelling system upgrades and the related achieved improvements. In order to evaluate the performance of the coupled system a set of experiments has been built by coupling the wave and circulation models that hourly exchange the following fields: the sea surface currents and air-sea temperature difference are transferred from NEMO model to WW3 model modifying respectively the mean momentum transfer of waves and the wind speed stability parameter; while the neutral drag coefficient computed by WW3 model is passed to NEMO that computes the turbulent component. In order to validate the modelling system, numerical results have been compared with in-situ and remote sensing data. This work suggests that a coupled model might be capable of a better description of wave-current interactions, in particular feedback from the ocean to the waves might assess an improvement on the prediction capability of wave characteristics, while suggests to proceed toward a fully

  20. Development of RF-linac and storage ring system for high-current experiments at GSI

    International Nuclear Information System (INIS)

    Hofmann, I.

    1986-08-01

    The heavy ion facility under construction at GSI is suitable for the generation of high-current beams. It consists of a new high-current injector into the Unilac and a synchrotron and storage ring. We discuss the capability of this system to produce short pulses of heavy ions with a specific energy of the order of 0.1 MJ/g. Under these conditions the system allows to perform a first generation of heavy ion driven target experiments and to test most of the critical issues of a large scale heavy ion fusion driver facility. (orig.)

  1. Method and system for a gas tube-based current source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  2. Automatic appraisal of defects in irradiated pins by eddy current testing

    International Nuclear Information System (INIS)

    Marsol, R.; Cornu, B.

    1986-10-01

    Eddy current testing is very efficient to inspect the sheaths of spent fuel elements. Automation of the process is developed to replace visual examination of recorded eddy current signals. The method is applied to austenitic steel fuel cans for fast neutron reactors to detect cracks, voids, inclusions... The different types of defects and experimental processes are recalled then automatic detection and the method for defect qualification are presented [fr

  3. The MDSplus data acquisition system, current status and future directions

    International Nuclear Information System (INIS)

    Stillerman, J.; Fredian, T.W.

    1999-01-01

    The MDSplus data acquisition system was developed in collaboration with the ZTH group at Los Alamos National Laboratory and the RFX group at CNR in Padua, Italy and is currently in use at MIT, RFX in Padua, and TCV at EPFL in Lausanne. MDSplus is based on a hierarchical experiment description which completely describes the data acquisition and analysis tasks and contains the results from these operations. It also includes a set of X/motif based tools for data acquisition and display, as well as diagnostic configuration and management. These tools were designed to operate in a distributed, client/server environment with multiple concurrent readers and writers to the data store. An interface to a relational database is provided for storage and management of processed data. A commercially available package called IDL is used as the primary data analysis and visualization tool. The current projects include a new interface to the electronic logbook, tools for remote collaborators and WWW access, and a port of the system to UNIX and Windows-NT/95. (orig.)

  4. Eddy properties in the Southern California Current System

    Science.gov (United States)

    Chenillat, Fanny; Franks, Peter J. S.; Capet, Xavier; Rivière, Pascal; Grima, Nicolas; Blanke, Bruno; Combes, Vincent

    2018-05-01

    The California Current System (CCS) is an eastern boundary upwelling system characterized by strong eddies that are often generated at the coast. These eddies contribute to intense, long-distance cross-shelf transport of upwelled water with enhanced biological activity. However, the mechanisms of formation of such coastal eddies, and more importantly their capacity to trap and transport tracers, are poorly understood. Their unpredictability and strong dynamics leave us with an incomplete picture of the physical and biological processes at work, their effects on coastal export, lateral water exchange among eddies and their surrounding waters, and how long and how far these eddies remain coherent structures. Focusing our analysis on the southern part of the CCS, we find a predominance of cyclonic eddies, with a 25-km radius and a SSH amplitude of 6 cm. They are formed near shore and travel slightly northwest offshore for 190 days at 2 km day-1. We then study one particular, representative cyclonic eddy using a combined Lagrangian and Eulerian numerical approach to characterize its kinematics. Formed near shore, this eddy trapped a core made up of 67% California Current waters and 33% California Undercurrent waters. This core was surrounded by other waters while the eddy detached from the coast, leaving the oldest waters at the eddy's core and the younger waters toward the edge. The eddy traveled several months as a coherent structure, with only limited lateral exchange within the eddy.

  5. Maximum power point tracking for PV systems under partial shading conditions using current sweeping

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2015-01-01

    Highlights: • A novel approach for tracking the maximum power point of photovoltaic systems. • Able to handle both the uniform insolation and partial shading conditions. • Maximum power point tracking based on current sweeping. - Abstract: Partial shading on photovoltaic (PV) arrays causes multiple peaks on the output power–voltage characteristic curve and local searching technique such as perturb and observe (P&O) method could easily fail in searching for the global maximum. Moreover, existing global searching techniques are still not very satisfactory in terms of speed and implementation complexity. In this paper, a fast global maximum power point (MPPT) tracking method which is using current sweeping for photovoltaic arrays under partial shading conditions is proposed. Unlike conventional approach, the proposed method is current based rather than voltage based. The initial maximum power point will be derived based on a current sweeping test and the maximum power point can be enhanced by a finer local search. The speed of the global search is mainly governed by the apparent time constant of the PV array and the generation of a fast current sweeping test. The fast current sweeping test can easily be realized by a DC/DC boost converter with a very fast current control loop. Experimental results are included to demonstrate the effectiveness of the proposed global searching scheme

  6. Laboratory results of the AOF system testing

    Science.gov (United States)

    Kolb, Johann; Madec, Pierre-Yves; Arsenault, Robin; Oberti, Sylvain; Paufique, Jérôme; La Penna, Paolo; Ströbele, Stefan; Donaldson, Robert; Soenke, Christian; Suárez Valles, Marcos; Kiekebusch, Mario; Argomedo, Javier; Le Louarn, Miska; Vernet, Elise; Haguenauer, Pierre; Duhoux, Philippe; Aller-Carpentier, Emmanuel; Valenzuela, Jose Javier; Guerra, Juan Carlos

    2016-07-01

    For two years starting in February 2014, the AO modules GRAAL for HAWK-I and GALACSI for MUSE of the Adaptive Optics Facility project have undergone System Testing at ESO's Headquarters. They offer four different modes: NGS SCAO, LGS GLAO in the IR, LGS GLAO and LTAO in the visible. A detailed characterization of those modes was made possible by the existence of ASSIST, a test bench emulating an adaptive VLT including the Deformable Secondary Mirror, a star simulator and turbulence generator and a VLT focal plane re-imager. This phase aimed at validating all the possible components and loops of the AO modules before installation at the actual VLT that comprises the added complexity of real LGSs, a harsher non-reproducible environment and the adaptive telescope control. In this paper we present some of the major results obtained and challenges encountered during the phase of System Tests, like the preparation of the Acquisition sequence, the testing of the Jitter loop, the performance optimization in GLAO and the offload of low-order modes from the DSM to the telescope (restricted to the M2 hexapod). The System Tests concluded with the successful acceptance, shipping, installation and first commissioning of GRAAL in 2015 as well as the acceptance and shipping of GALACSI, ready for installation and commissioning early 2017.

  7. Testing on air cleaning systems: Testing of the components in-place tests

    International Nuclear Information System (INIS)

    Billard, F.; Brion, J.

    1967-01-01

    The reliability of air cleaning systems is dependent on testing they are submitted to. Although in-place tests are the most important as they act as final tests upon achieved plants, component tests are necessary too. They allow detection of defective units before they are installed, partition of unit defects from mounting defects and they are more sensitive. For similar reasons, material teats are most useful. The various tests are described, about aerosol filters for one part, iodine trap for the other. The checked features are: materials nature, units sizes, efficiency, air resistance, flammability, humidity resistance, temperature resistance, adsorbent friability, etc... On iodine trapping systems, small check traps, working by-pass with the main trap are periodically subjected to efficiency test. This control allow to cut down the in-place tests frequency, particularly when poisoning from organic vapours is to be feared. (authors) [fr

  8. Developing a solar panel testing system

    Directory of Open Access Journals (Sweden)

    Árpád Rácz

    2009-10-01

    Full Text Available Solar energy is increasingly used togenerate electricity for individual households. There isa wide variety of solar panel technologies, whichshould be tested at an individual level during theirlifetime. In this paper, the development of a testingstation at the University of Debrecen is presented. Thetesting system can be used for research andeducational purposes and for in field applicationsequally well.

  9. Modeling, Simulation, and Experiment of Switched Reluctance Ocean Current Generator System

    Directory of Open Access Journals (Sweden)

    Hao Chen

    2013-01-01

    Full Text Available This paper presents nonlinear simulation model of switched reluctance (SR ocean current generator system on MATLAB/SIMULINK with describing the structure of generator system. The developed model is made up of main model, rotor position calculation module, controller module, gate module, power converter module, phase windings module, flux-linkage module, torque module, and power calculation module. The magnetization curves obtained by two-dimensional finite-element electromagnetic field calculation and the conjugated magnetic energy graphics obtained from the three-dimensional graphics of flux linkage are stored in the “Lookup Table” modules on MATLAB/SIMULINK. The hardware of the developed three-phase 12/8 structure SR ocean current generator system prototype with the experimental platform is presented. The simulation of the prototype is performed by the developed models, and the experiments have been carried out under the same condition with different output power, turn-off angle, and rotor speed. The simulated phase current waveforms agree well with the tested phase current waveforms experimentally. The simulated output voltage curves agree well with the tested output voltage curves experimentally. It is shown that the developed nonlinear simulation model of the three-phase 12/8 structure SR ocean current generator system is valid.

  10. Virtualization of System of Systems Test and Evaluation

    Science.gov (United States)

    2012-06-04

    computers and is the primary enabler for virtualization. 2. Virtualization System Elements Parmalee, Peterson , Tillman, & Hatfield (1972) outlined the...The work of Abu-Taieh and El Sheikh, based on the work of Balci (1994, 1995), and Balci et al. ( 1996 ), seeks to organize types of tests and to...and testing. In A. Dasso & A. Funes (Eds.), Verification, validation, and testing in software engineering (pp. 155–184). Hershey , PA: Idea Group

  11. Tritium system test assembly control system cost estimate

    International Nuclear Information System (INIS)

    Stutz, R.A.

    1979-01-01

    The principal objectives of the Tritium Systems Test Assembly (TSTA), which includes the development, demonstration and interfacing of technologies related to the deuterium--tritium fuel cycle for fusion reactor systems, are concisely stated. The various integrated subsystems comprising TSTA and their functions are discussed. Each of the four major subdivisions of TSTA, including the main process system, the environmental and safety systems, supporting systems and the physical plant are briefly discussed. An overview of the Master Data Acquisition and Control System, which will control all functional operation of TSTA, is provided

  12. Testing of quality of welded joints using heavy-current pulse X-ray apparatuses

    International Nuclear Information System (INIS)

    Gusev, E.A.; Firstov, V.G.

    1988-01-01

    The possibilities of carrying out of radiographic and electroradiographic testing of quality of welded joints using heavy-current pulse X-ray apparatuses under the mode of single pulses are shown. Basic quantitative characteristics of radiographic testing permitting to detect the focus distance, sensitivity behaviour and optical density of image are presented. Peculiarities of electroradiographic image formation under the mode of single pulses of nanosecond range are analysed. The outlook of heavy-current pulse X-ray apparatus application under the mode of single pulses in industry is estimated

  13. Design of Jet lower hybrid current drive generator and operation of high power test bed

    International Nuclear Information System (INIS)

    Dobbing, J.A.; Bosia, G.; Brandon, M.; Gammelin, M.; Gormezano, C.; Jacquinot, J.; Jessop, G.; Lennholm, M.; Pain, M.; Sibley, A.

    1989-01-01

    The JET Lower Hybrid Current Drive (LHCD) generator consists of 24 klystrons each rated for 650 KW operating at 3.7 GHz, giving a nominal generator power of 15.6 MW for 10 seconds or 12 MW for 20 seconds. This power will be transmitted through 24 waveguides to a phased array launcher on one of the main ports of the JET machine. In addition, two klystrons are currently being operated on a high power test bed to establish reliable operation of the generators components and test high power microwave components prior to their installation

  14. Mars Science Laboratory Rover System Thermal Test

    Science.gov (United States)

    Novak, Keith S.; Kempenaar, Joshua E.; Liu, Yuanming; Bhandari, Pradeep; Dudik, Brenda A.

    2012-01-01

    On November 26, 2011, NASA launched a large (900 kg) rover as part of the Mars Science Laboratory (MSL) mission to Mars. The MSL rover is scheduled to land on Mars on August 5, 2012. Prior to launch, the Rover was successfully operated in simulated mission extreme environments during a 16-day long Rover System Thermal Test (STT). This paper describes the MSL Rover STT, test planning, test execution, test results, thermal model correlation and flight predictions. The rover was tested in the JPL 25-Foot Diameter Space Simulator Facility at the Jet Propulsion Laboratory (JPL). The Rover operated in simulated Cruise (vacuum) and Mars Surface environments (8 Torr nitrogen gas) with mission extreme hot and cold boundary conditions. A Xenon lamp solar simulator was used to impose simulated solar loads on the rover during a bounding hot case and during a simulated Mars diurnal test case. All thermal hardware was exercised and performed nominally. The Rover Heat Rejection System, a liquid-phase fluid loop used to transport heat in and out of the electronics boxes inside the rover chassis, performed better than predicted. Steady state and transient data were collected to allow correlation of analytical thermal models. These thermal models were subsequently used to predict rover thermal performance for the MSL Gale Crater landing site. Models predict that critical hardware temperatures will be maintained within allowable flight limits over the entire 669 Sol surface mission.

  15. LEDA RF distribution system design and component test results

    International Nuclear Information System (INIS)

    Roybal, W.T.; Rees, D.E.; Borchert, H.L.; McCarthy, M.; Toole, L.

    1998-01-01

    The 350 MHz and 700 MHz RF distribution systems for the Low Energy Demonstration Accelerator (LEDA) have been designed and are currently being installed at Los Alamos National Laboratory. Since 350 MHz is a familiar frequency used at other accelerator facilities, most of the major high-power components were available. The 700 MHz, 1.0 MW, CW RF delivery system designed for LEDA is a new development. Therefore, high-power circulators, waterloads, phase shifters, switches, and harmonic filters had to be designed and built for this applications. The final Accelerator Production of Tritium (APT) RF distribution systems design will be based on much of the same technology as the LEDA systems and will have many of the RF components tested for LEDA incorporated into the design. Low power and high-power tests performed on various components of these LEDA systems and their results are presented here

  16. Quantitative Sensory Testing and Current Perception Threshold Testing in Patients With Chronic Pain Following Lower Extremity Fracture.

    Science.gov (United States)

    Griffioen, Mari A; Greenspan, Joel D; Johantgen, Meg; Von Rueden, Kathryn; O'Toole, Robert V; Dorsey, Susan G; Renn, Cynthia L

    2018-01-01

    Chronic pain is a significant problem for patients with lower extremity injuries. While pain hypersensitivity has been identified in many chronic pain conditions, it is not known whether patients with chronic pain following lower extremity fracture report pain hypersensitivity in the injured leg. To quantify and compare peripheral somatosensory function and sensory nerve activation thresholds in persons with chronic pain following lower extremity fractures with a cohort of persons with no history of lower extremity fractures. This was a cross-sectional study where quantitative sensory testing and current perception threshold testing were conducted on the injured and noninjured legs of cases and both legs of controls. A total of 14 cases and 28 controls participated in the study. Mean time since injury at the time of testing for cases was 22.3 (standard deviation = 12.1) months. The warmth detection threshold ( p = .024) and nerve activation thresholds at 2,000 Hz ( p sensory nerve function at the site of injury in patients with chronic pain following lower extremity fractures using quantitative sensory testing and current perception threshold testing.

  17. DC current distribution mapping system of the solar panels using a HTS-SQUID gradiometer

    International Nuclear Information System (INIS)

    Miyazaki, Shingo; Kasuya, Syohei; Saari, Mohd Mawardi; Sakai, Kenji; Kiwa, Toshihiko; Tsukada, Keiji; Tsukamoto, Akira; Adachi, Seiji; Tanabe, Keiichi

    2014-01-01

    Solar panels are expected to play a major role as a source of sustainable energy. In order to evaluate solar panels, non-destructive tests, such as defect inspections and response property evaluations, are necessary. We developed a DC current distribution mapping system of the solar panels using a High Critical Temperature Superconductor Superconducting Quantum Interference Device (HTS-SQUID) gradiometer with ramp edge type Josephson junctions. Two independent components of the magnetic fields perpendicular to the panel surface (∂Bz/∂x, ∂Bz/∂y) were detected. The direct current of the solar panel is visualized by calculating the composition of the two signal components, the phase angle, and mapping the DC current vector. The developed system can evaluate the uniformity of DC current distributions precisely and may be applicable for defect detection of solar panels.

  18. Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.

    Science.gov (United States)

    Mégraud, F

    1996-01-01

    Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.

  19. Prototype Engineered Barrier System Field Tests (PEBSFT)

    International Nuclear Information System (INIS)

    Ramirez, A.L.; Wilder, D.G.

    1991-02-01

    This progress report presents the interpretation of data obtained (up to November 1, 1988) from the Prototype Engineered Barrier System Field Tests (PEBSFT) that are being performed for the Yucca Mountain Project (YMP) in G-Tunnel within the Nevada Test site. The PEBSFTs are being conducted to evaluate the applicability of measurement techniques, numerical models, and procedures developed for the field tests for future investigations that will be conducted in the Exploratory Shaft Facilities, at a potential high-level radioactive waste repository site in Yucca Mountain. The primary objective of the tests is to provide the basis for determining whether tests planned for Yucca Mountain have the potential to be successful. Thirteen chapters discuss the following: mapping the electromagnetic permittivity and attenuation rate of the rock mass; changes in moisture content detected by the neutron logging probe; characterization of the in-situ permeability of the fractured tuff around the heater borehole; electrical resistance heater installed in a 30-cm borehole; relative humidity measurements; the operation, design, construction, calibration, and installation of a microwave circuit that might provide partial pressure information at temperatures in excess of 200 degree C (392 degree F); pressure and temperature measurements in the G-Tunnel; the moisture collection system, which attempts to collect steam that migrates into the heater borehole; The borehole television and borescope surveys that were performed to map the location, orientation, and aperture of the fractures intersecting the boreholes; preliminary scoping calculations of the hydrothermal conditions expected for this prototype test; the Data Acquisition System; and the results of the PEBSFT, preliminary interpretations of these results, and plans for the remainder of the test. Chapters have been indexed separately for inclusion on the data base

  20. Design and simulations for RFPI system test jig

    International Nuclear Information System (INIS)

    Keshwani, Rajesh; Khole, Shailesh; Sujo, C.I.; Shukla, Hitesh; Afaash, M.; Bharade, Sandeep; Joshi, Gopal

    2015-01-01

    RFPI system for condition monitoring and protection of RF systems of LEHIPA has been designed. The intention of this system is to protect and monitor different high power RF components. The system consists of variety of analog and digital cards to process, acquire and monitor signals from RF sensors, photo multiplier tubes (PMT), field emission probes, photo sensors, etc. The system can also accept and process digital inputs or contacts and analog input signals from other subsystems, indicating their status. It comprises of analog signal processing electronics, condition monitoring, data acquisition and fault reporting features. Since RFPI system should process and take action within prescribed time limit, the testing of system is critical issue. In order to carry out stand-alone field testing of such elaborate electronic system, variety of carefully designed electronic test circuit with suitable rangeability is required. These include fast current sources, fast amplifiers, fast rectifiers, etc. This paper elaborates on specifications, design approach, circuit design and simulations for various circuits used in test jig

  1. INEL test plan for evaluating waste assay systems

    International Nuclear Information System (INIS)

    Mandler, J.W.; Becker, G.K.; Harker, Y.D.; Menkhaus, D.E.; Clements, T.L. Jr.

    1996-09-01

    A test bed is being established at the Idaho National Engineering Laboratory (INEL) Radioactive Waste Management Complex (RWMC). These tests are currently focused on mobile or portable radioassay systems. Prior to disposal of TRU waste at the Waste Isolation Pilot Plant (WIPP), radioassay measurements must meet the quality assurance objectives of the TRU Waste Characterization Quality Assurance Program Plan. This test plan provides technology holders with the opportunity to assess radioassay system performance through a three-tiered test program that consists of: (a) evaluations using non-interfering matrices, (b) surrogate drums with contents that resemble the attributes of INEL-specific waste forms, and (c) real waste tests. Qualified sources containing a known mixture and range of radionuclides will be used for the non-interfering and surrogate waste tests. The results of these tests will provide technology holders with information concerning radioassay system performance and provide the INEL with data useful for making decisions concerning alternative or improved radioassay systems that could support disposal of waste at WIPP

  2. INEL test plan for evaluating waste assay systems

    Energy Technology Data Exchange (ETDEWEB)

    Mandler, J.W.; Becker, G.K.; Harker, Y.D.; Menkhaus, D.E.; Clements, T.L. Jr.

    1996-09-01

    A test bed is being established at the Idaho National Engineering Laboratory (INEL) Radioactive Waste Management Complex (RWMC). These tests are currently focused on mobile or portable radioassay systems. Prior to disposal of TRU waste at the Waste Isolation Pilot Plant (WIPP), radioassay measurements must meet the quality assurance objectives of the TRU Waste Characterization Quality Assurance Program Plan. This test plan provides technology holders with the opportunity to assess radioassay system performance through a three-tiered test program that consists of: (a) evaluations using non-interfering matrices, (b) surrogate drums with contents that resemble the attributes of INEL-specific waste forms, and (c) real waste tests. Qualified sources containing a known mixture and range of radionuclides will be used for the non-interfering and surrogate waste tests. The results of these tests will provide technology holders with information concerning radioassay system performance and provide the INEL with data useful for making decisions concerning alternative or improved radioassay systems that could support disposal of waste at WIPP.

  3. System Quality Management in Software Testing Laboratory that Chooses Accreditation

    Directory of Open Access Journals (Sweden)

    Yanet Brito R.

    2013-12-01

    Full Text Available The evaluation of software products will reach full maturity when executed by the scheme and provides third party certification. For the validity of the certification, the independent laboratory must be accredited for that function, using internationally recognized standards. This brings with it a challenge for the Industrial Laboratory Testing Software (LIPS, responsible for testing the products developed in Cuban Software Industry, define strategies that will permit it to offer services with a high level of quality. Therefore it is necessary to establish a system of quality management according to NC-ISO/IEC 17025: 2006 to continuously improve the operational capacity and technical competence of the laboratory, with a view to future accreditation of tests performed. This article discusses the process defined in the LIPS for the implementation of a Management System of Quality, from the current standards and trends, as a necessary step to opt for the accreditation of the tests performed.

  4. Real time Aanderaa current meter data collection system

    Digital Repository Service at National Institute of Oceanography (India)

    AshokKumar, K.; Diwan, S.G.

    Aanderaa current meters are widely used for recording the current speed and such other 4 parameters by deploying them over extended period of time. Normally data are recorded on magnetic tape and after recovery of current meters, data are read...

  5. Evolution of a test article handling system for the SP-100 ground engineering system test

    International Nuclear Information System (INIS)

    Shen, E.J.; Schweiger, L.J.; Miller, W.C.; Gluck, R.; Devies, S.M.

    1987-04-01

    A simulated space environment test of a flight prototypic SP-100 reactor, control system, and flight shield will be conducted at the Hanford Engineering Development Laboratory (HEDL). The flight prototypic components and the supporting primary heat removal system are collectively known as the Nuclear Assembly Test Article (TA). The unique configuration and materials of fabrication for the Test Article require a specialized handling facility to support installation, maintenance, and final disposal operations. Westinghouse Hanford Company, the Test Site Operator, working in conjunction with General Electric Company, the Test Article supplier, developed and evaluated several handling concepts resulting in the selection of a reference Test Article Handling System. The development of the reference concept for the handling system is presented

  6. Determination of plasma spot current and arc discharge plasma current on the system of plasma cathode electron sources using Rogowski coil technique

    International Nuclear Information System (INIS)

    Wirjoadi; Bambang Siswanto; Lely Susita RM; Agus Purwadi; Sudjatmoko

    2015-01-01

    It has been done the function test experiments of ignitor electrode system and the plasma generator electrode system to determine the current spot plasma and arc discharge plasma current with Rogowski coil technique. Ignitor electrode system that gets power supply from IDPS system can generate the plasma spot current of 11.68 ampere to the pulse width of about 33 μs, this value is greater than the design probably because of electronic components used in the IDPS system was not as planned. For the plasma generator electrode system that gets power from ADPS system capable of producing an arc discharge plasma current around 103.15 amperes with a pulse width of about 96 μs, and this value as planned. Based on the value of the arc discharge plasma current can be determined plasma electron density, which is about 10.12 10"1"9 electrons/m"3, and with this electron density value, an ignitor electrode system and a plasma generator system is quite good if used as a plasma cathode electron source system. (author)

  7. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    Energy Technology Data Exchange (ETDEWEB)

    Lu, D.F.; Fan, C.; Ruan, J.Z. [Midwest Superconductivity Inc., Lawrence, KS (United States)] [and others

    1994-12-31

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology.

  8. Non-destructive testing (NDT) of metal cracks using a high Tc rf-SQUID and eddy current method

    International Nuclear Information System (INIS)

    Lu, D.F.; Fan, C.; Ruan, J.Z.

    1994-01-01

    A SQUID is the most sensitive device to detect change in magnetic field. A non-destructive testing (NDT) device using high temperature SQUIDs and eddy current method will be much more sensitive than those currently used eddy current systems, yet much cheaper than one with low temperature SQUIDs. In this paper, we present our study of such a NDT device using a high temperature superconducting rf-SQUID as a gradiometer sensor. The result clearly demonstrates the expected sensitivity of the system, and indicates the feasibility of building a portable HTS SQUID NDT device with the help from cryocooler industry. Such a NDT device will have a significant impact on metal corrosion or crack detection technology

  9. Integrated System Health Management (ISHM) Implementation in Rocket Engine Testing

    Science.gov (United States)

    Figueroa, Fernando; Morris, Jon; Turowski, Mark; Franzl, Richard; Walker, Mark; Kapadia, Ravi; Venkatesh, Meera

    2010-01-01

    A pilot operational ISHM capability has been implemented for the E-2 Rocket Engine Test Stand (RETS) and a Chemical Steam Generator (CSG) test article at NASA Stennis Space Center. The implementation currently includes an ISHM computer and a large display in the control room. The paper will address the overall approach, tools, and requirements. It will also address the infrastructure and architecture. Specific anomaly detection algorithms will be discussed regarding leak detection and diagnostics, valve validation, and sensor validation. It will also describe development and use of a Health Assessment Database System (HADS) as a repository for measurements, health, configuration, and knowledge related to a system with ISHM capability. It will conclude with a discussion of user interfaces, and a description of the operation of the ISHM system prior, during, and after testing.

  10. CRISPR technologies for bacterial systems: Current achievements and future directions.

    Science.gov (United States)

    Choi, Kyeong Rok; Lee, Sang Yup

    2016-11-15

    Throughout the decades of its history, the advances in bacteria-based bio-industries have coincided with great leaps in strain engineering technologies. Recently unveiled clustered regularly interspaced short palindromic repeats (CRISPR)/CRISPR-associated proteins (Cas) systems are now revolutionizing biotechnology as well as biology. Diverse technologies have been derived from CRISPR/Cas systems in bacteria, yet the applications unfortunately have not been actively employed in bacteria as extensively as in eukaryotic organisms. A recent trend of engineering less explored strains in industrial microbiology-metabolic engineering, synthetic biology, and other related disciplines-is demanding facile yet robust tools, and various CRISPR technologies have potential to cater to the demands. Here, we briefly review the science in CRISPR/Cas systems and the milestone inventions that enabled numerous CRISPR technologies. Next, we describe CRISPR/Cas-derived technologies for bacterial strain development, including genome editing and gene expression regulation applications. Then, other CRISPR technologies possessing great potential for industrial applications are described, including typing and tracking of bacterial strains, virome identification, vaccination of bacteria, and advanced antimicrobial approaches. For each application, we note our suggestions for additional improvements as well. In the same context, replication of CRISPR/Cas-based chromosome imaging technologies developed originally in eukaryotic systems is introduced with its potential impact on studying bacterial chromosomal dynamics. Also, the current patent status of CRISPR technologies is reviewed. Finally, we provide some insights to the future of CRISPR technologies for bacterial systems by proposing complementary techniques to be developed for the use of CRISPR technologies in even wider range of applications. Copyright © 2016. Published by Elsevier Inc.

  11. Thermionic system evaluated test (TSET) facility description

    Science.gov (United States)

    Fairchild, Jerry F.; Koonmen, James P.; Thome, Frank V.

    1992-01-01

    A consortium of US agencies are involved in the Thermionic System Evaluation Test (TSET) which is being supported by the Strategic Defense Initiative Organization (SDIO). The project is a ground test of an unfueled Soviet TOPAZ-II in-core thermionic space reactor powered by electrical heat. It is part of the United States' national thermionic space nuclear power program. It will be tested in Albuquerque, New Mexico at the New Mexico Engineering Research Institute complex by the Phillips Laboratoty, Sandia National Laboratories, Los Alamos National Laboratory, and the University of New Mexico. One of TSET's many objectives is to demonstrate that the US can operate and test a complete space nuclear power system, in the electrical heater configuration, at a low cost. Great efforts have been made to help reduce facility costs during the first phase of this project. These costs include structural, mechanical, and electrical modifications to the existing facility as well as the installation of additional emergency systems to mitigate the effects of utility power losses and alkali metal fires.

  12. Current understanding of interactions between nanoparticles and the immune system

    International Nuclear Information System (INIS)

    Dobrovolskaia, Marina A.; Shurin, Michael; Shvedova, Anna A.

    2016-01-01

    The delivery of drugs, antigens, and imaging agents benefits from using nanotechnology-based carriers. The successful translation of nanoformulations to the clinic involves thorough assessment of their safety profiles, which, among other end-points, includes evaluation of immunotoxicity. The past decade of research focusing on nanoparticle interaction with the immune system has been fruitful in terms of understanding the basics of nanoparticle immunocompatibility, developing a bioanalytical infrastructure to screen for nanoparticle-mediated immune reactions, beginning to uncover the mechanisms of nanoparticle immunotoxicity, and utilizing current knowledge about the structure–activity relationship between nanoparticles' physicochemical properties and their effects on the immune system to guide safe drug delivery. In the present review, we focus on the most prominent pieces of the nanoparticle–immune system puzzle and discuss the achievements, disappointments, and lessons learned over the past 15 years of research on the immunotoxicity of engineered nanomaterials. - Graphical abstract: API — active pharmaceutical ingredient; NP — nanoparticles; PCP — physicochemical properties, CARPA — complement activation-related pseudoallergy, ICH — International Conference on Harmonization. Display Omitted - Highlights: • Achievements, disappointments and lessons learned over past decade are reviewed. • Areas in focus include characterization, immunotoxicity and utility in drug delivery. • Future direction focusing on mechanistic immunotoxicity studies is proposed.

  13. The Cuban health care system and factors currently undermining it.

    Science.gov (United States)

    Nayeri, K

    1995-08-01

    This paper explores the dynamics of health and health care in Cuba during a period of severe crisis by placing it within its economic, social, and political context using a comparative historical approach. It outlines Cuban achievements in health care as a consequence of the socialist transformations since 1959, noting the full commitment by the Cuban state, the planned economy, mass participation, and a self-critical, working class perspective as crucial factors. The roles of two external factors, the U.S. economic embargo and the Council of Mutual Economic Cooperation (CMEA), are explored in shaping the Cuban society and economy, including its health care system. It is argued that the former has hindered health efforts in Cuba. The role of the latter is more complex. While the CMEA was an important source for economic growth, Cuban relations with the Soviet bloc had a damaging effect on the development of socialism in Cuba. The adoption of the Soviet model of economic development fostered bureaucracy and demoralization of Cuban workers. As such, it contributed to two internal factors that have undermined further social progress including in health care: low productivity of labor and the growth of bureaucracy. While the health care system is still consistently supported by public policy and its structure is sound, economic crisis undermines its material and moral foundations and threatens its achievements. The future of the current Cuban health care system is intertwined with the potentials for its socialist development.

  14. Review on the current trends in tongue diagnosis systems

    Directory of Open Access Journals (Sweden)

    Chang Jin Jung

    2012-12-01

    Full Text Available Tongue diagnosis is an essential process to noninvasively assess the condition of a patient's internal organs in traditional medicine. To obtain quantitative and objective diagnostic results, image acquisition and analysis devices called tongue diagnosis systems (TDSs are required. These systems consist of hardware including cameras, light sources, and a ColorChecker, and software for color correction, segmentation of tongue region, and tongue classification. To improve the performance of TDSs, various types TDSs have been developed. Hyperspectral imaging TDSs have been suggested to acquire more information than a two-dimensional (2D image with visible light waves, as it allows collection of data from multiple bands. Three-dimensional (3D imaging TDSs have been suggested to provide 3D geometry. In the near future, mobile devices like the smart phone will offer applications for assessment of health condition using tongue images. Various technologies for the TDS have respective unique advantages and specificities according to the application and diagnostic environment, but this variation may cause inconsistent diagnoses in practical clinical applications. In this manuscript, we reviewed the current trends in TDSs for the standardization of systems. In conclusion, the standardization of TDSs can supply the general public and oriental medical doctors with convenient, prompt, and accurate information with diagnostic results for assessing the health condition.

  15. Current understanding of interactions between nanoparticles and the immune system

    Energy Technology Data Exchange (ETDEWEB)

    Dobrovolskaia, Marina A., E-mail: marina@mail.nih.gov [Nanotechnology Characterization Laboratory, Cancer Research Technology Program, Leidos Biomedical Research Inc., Frederick National Laboratory for Cancer Research, NCI at Frederick, Frederick, MD 21702 (United States); Shurin, Michael [Department of Pathology, University of Pittsburgh Medical Center, Pittsburgh, PA 15213 (United States); Department of Immunology, University of Pittsburgh Medical Center, Pittsburgh, PA 15213 (United States); Shvedova, Anna A., E-mail: ats1@cdc.gov [Health Effects Laboratory Division, National Institute of Occupational Safety and Health, Centers for Disease Control and Prevention, Morgantown, WV 26505 (United States); Department of Physiology and Pharmacology, West Virginia University, Morgantown, WV 26506 (United States)

    2016-05-15

    The delivery of drugs, antigens, and imaging agents benefits from using nanotechnology-based carriers. The successful translation of nanoformulations to the clinic involves thorough assessment of their safety profiles, which, among other end-points, includes evaluation of immunotoxicity. The past decade of research focusing on nanoparticle interaction with the immune system has been fruitful in terms of understanding the basics of nanoparticle immunocompatibility, developing a bioanalytical infrastructure to screen for nanoparticle-mediated immune reactions, beginning to uncover the mechanisms of nanoparticle immunotoxicity, and utilizing current knowledge about the structure–activity relationship between nanoparticles' physicochemical properties and their effects on the immune system to guide safe drug delivery. In the present review, we focus on the most prominent pieces of the nanoparticle–immune system puzzle and discuss the achievements, disappointments, and lessons learned over the past 15 years of research on the immunotoxicity of engineered nanomaterials. - Graphical abstract: API — active pharmaceutical ingredient; NP — nanoparticles; PCP — physicochemical properties, CARPA — complement activation-related pseudoallergy, ICH — International Conference on Harmonization. Display Omitted - Highlights: • Achievements, disappointments and lessons learned over past decade are reviewed. • Areas in focus include characterization, immunotoxicity and utility in drug delivery. • Future direction focusing on mechanistic immunotoxicity studies is proposed.

  16. Discrete changes of current statistics in periodically driven stochastic systems

    International Nuclear Information System (INIS)

    Chernyak, Vladimir Y; Sinitsyn, N A

    2010-01-01

    We demonstrate that the counting statistics of currents in periodically driven ergodic stochastic systems can show sharp changes of some of its properties in response to continuous changes of the driving protocol. To describe this effect, we introduce a new topological phase factor in the evolution of the moment generating function which is akin to the topological geometric phase in the evolution of a periodically driven quantum mechanical system with time-reversal symmetry. This phase leads to the prediction of a sign change for the difference of the probabilities to find even and odd numbers of particles transferred in a stochastic system in response to cyclic evolution of control parameters. The driving protocols that lead to this sign change should enclose specific degeneracy points in the space of control parameters. The relation between the topology of the paths in the control parameter space and the sign changes can be described in terms of the first Stiefel–Whitney class of topological invariants. (letter)

  17. Review on the current trends in tongue diagnosis systems.

    Science.gov (United States)

    Jung, Chang Jin; Jeon, Young Ju; Kim, Jong Yeol; Kim, Keun Ho

    2012-12-01

    Tongue diagnosis is an essential process to noninvasively assess the condition of a patient's internal organs in traditional medicine. To obtain quantitative and objective diagnostic results, image acquisition and analysis devices called tongue diagnosis systems (TDSs) are required. These systems consist of hardware including cameras, light sources, and a ColorChecker, and software for color correction, segmentation of tongue region, and tongue classification. To improve the performance of TDSs, various types TDSs have been developed. Hyperspectral imaging TDSs have been suggested to acquire more information than a two-dimensional (2D) image with visible light waves, as it allows collection of data from multiple bands. Three-dimensional (3D) imaging TDSs have been suggested to provide 3D geometry. In the near future, mobile devices like the smart phone will offer applications for assessment of health condition using tongue images. Various technologies for the TDS have respective unique advantages and specificities according to the application and diagnostic environment, but this variation may cause inconsistent diagnoses in practical clinical applications. In this manuscript, we reviewed the current trends in TDSs for the standardization of systems. In conclusion, the standardization of TDSs can supply the general public and oriental medical doctors with convenient, prompt, and accurate information with diagnostic results for assessing the health condition.

  18. Integration Tests of the Muon System

    CERN Multimedia

    Cerutti, F; Palestini, S

    A complex large-size prototype of the Muon system is installed in the test area H8B in Prévessin; the set-up includes chambers belonging to the three layers of the Barrel Spectrometer (on the right in Figure 1), and chambers belonging to one octant of the End Cap Spectrometer (center and left side of Figure 1). Figure 1: Set-up of the Muon spectrometer integration test. The installation accurately reproduces the geometry of regions of the ATLAS Muon Spectrometer, with the H8 beam-line crossing the detectors at positions/angles corresponding to particles with polar angle of 75 ± 4 and 15 ± 4 degrees, respectively for the Barrel and the End Cap. A comprehensive test program is being carried out with this set-up, ranging from tests of support frames (octant of the MDT BigWheel and of the SmallWheel) and of handling/installation of tracking chambers, to real-size tests of the alignment systems, together with accurate studies of performance and calibration of the precision chambers, and with develo...

  19. Tritium systems test assembly quality assurance program

    International Nuclear Information System (INIS)

    Kerstiens, F.L.; Wilhelm, R.C.

    1986-07-01

    A quality assurance program should establish the planned and systematic actions necessary to provide adequate confidence that fusion facilities and their subsystems will perform satisfactorily in service. The Tritium Systems Test Assembly (TSTA) Quality Assurance Program has been designed to assure that the designs, tests, data, and interpretive reports developed at TSTA are valid, accurate, and consistent with formally specified procedures and reviews. The quality consideration in all TSTA activities is directed toward the early detection of quality problems, coupled with timely and positive disposition and corrective action

  20. Eddy current testing device for metallic tubes at least locally curved

    International Nuclear Information System (INIS)

    Pigeon, Marcel; Vienot, Claude.

    1975-01-01

    Steam generators, condensers and heat exchangers generally consist of metallic tube bundles, the tubes having a complex geometry. The invention concerns an Eddy current testing device for metallic tubes at least locally curved, operating by translation of a probe inside the tubes [fr

  1. NDE reliability gains from combining eddy-current and ultrasonic testing

    International Nuclear Information System (INIS)

    Horn, D.; Mayo, W.R.

    1999-01-01

    We investigate statistical methods for combining the results of two complementary inspection techniques, eddy-current and ultrasonic testing. The reliability of rejection/acceptance decisions based on combined information is compared with that based on each inspection technique individually. The measured reliability increases with the amount of information incorporated in the decision. (author)

  2. The high current test facility injector operation to 40 mA dc

    International Nuclear Information System (INIS)

    Ungrin, J.; Ormrod, J.H.; Michel, W.L.

    1976-01-01

    The high current test facility injector is a 750 keV proton accelerator designed to investigate the problems involved in the acceleration of intense dc proton beams. The performance of the injector and the experience gained in operation with dc beams up to 40 mA are described. (author)

  3. A method for crack profiles identification in eddy current testing by the multi-directional scan

    International Nuclear Information System (INIS)

    Kojima, Fumio; Ikeda, Takuya; Nguyen, Doung

    2006-01-01

    This paper is concerned with a method for identification of crack shape in conducting materials. Multi-directional scanning strategies using Eddy Current Testing is performed for sizing complex natural crackings. Two dimensional measurements by means of multi-directional scan are used in a output least square identifications. (author)

  4. Tests of μ-e universality for weak neutral currents at PEP

    International Nuclear Information System (INIS)

    Cline, D.B.; Resvanis, L.K.

    1988-01-01

    Two techniques are proposed to test the universality of the μ/minus/e weak neutral current interaction of large Q 2 . Both techniques require large statistics and some degree of longitudinal e + ,e/sup minus/ polarization but are otherwise feasible at PEP

  5. Influence of residual stresses during eddy current testing of zircaloy bar material

    International Nuclear Information System (INIS)

    Saibaba, N.; Das, G.; Pratap, Y.; Acharya, S.; Chaube, R.K.; Jayaraj, R.N.

    2009-01-01

    Full text: Zirconium alloy bar is the input material for making end plugs required for encapsulating the fuel tubes after loading of uranium di-oxide pellets. These bars are manufactured through extrusion followed by multi-pass swaging and intermediate vacuum annealing. The bar is subjected to 100% Ultrasonic testing to ensure that defect free material is used for making the end plugs. The elements thus welded are subjected to helium leak testing for checking the weld integrity. However, stray cases of helium leakage from fuel elements were observed on few occasions. On investigation, it was found that the leakage was from small porosity present in the plugs. In order to isolate such an eventuality, stricter ultrasonic standards were adopted and additionally eddy current testing was introduced. It was observed that a number of eddy current signals equal to the defect standard were noticed and the reasons for these indications could not be identified. This led to a significant fall in the material recovery. An in-depth study with various heat treatment cycles and process steps was carried out. It was finally concluded that the indications observed in eddy current testing were due to the residual stresses on the periphery of the bar material caused due by improper straightening being carried out at the final stage of the bar manufacture. This paper presents the systematic studies carried out and correlation established between the eddy current signals and the residual stresses

  6. Operational test report - Project W-320 cathodic protection systems

    International Nuclear Information System (INIS)

    Bowman, T.J.

    1998-01-01

    Washington Administrative Code (WAC) 173-303-640 specifies that corrosion protection must be designed into tank systems that treat or store dangerous wastes. Project W-320, Waste Retrieval Sluicing System (WRSS), utilizes underground encased waste transfer piping between tanks 241-C-106 and 241-AY-102. Corrosion protection is afforded to the encasements of the WRSS waste transfer piping through the application of earthen ionic currents onto the surface of the piping encasements. Cathodic protection is used in conjunction with the protective coatings that are applied upon the WRSS encasement piping. WRSS installed two new two rectifier systems (46 and 47) and modified one rectifier system (31). WAC 173-303-640 specifies that the proper operation of cathodic protection systems must be confirmed within six months after initial installation. The WRSS cathodic protection systems were energized to begin continuous operation on 5/5/98. Sixteen days after the initial steady-state start-up of the WRSS rectifier systems, the operational testing was accomplished with procedure OTP-320-006 Rev/Mod A-0. This operational test report documents the OTP-320-006 results and documents the results of configuration testing of integrated piping and rectifier systems associated with the W-320 cathodic protection systems

  7. Testing The Enhanced Data Authentication System (EDAS)

    International Nuclear Information System (INIS)

    Thomas, M.; Baldwin, G.; Hymel, R.; Goncalves, J.G.M.; Dechamp, L.; ); Johnson, S.; Smejkal, A.; Linnebach, R.; Rue, M.

    2015-01-01

    The Enhanced Data Authentication System (EDAS) is a secure branching concept that provides a safeguards inspectorate a copy of measurement data from operator instrumentation. Both safeguards inspector and facility operator requirements for secure branching have been established in previous work. These dictated the design and development of EDAS hardware and software. This paper presents the test plan for the EDAS prototypes, which need to demonstrate performance against the identified requirements. Sandia National Laboratories (SNL), Directorate-General for Energy (DG-Energy) in Luxembourg, and the Joint Research Centre (JRC) in Ispra will each perform different tests on the EDAS prototypes. Sandia, the developer, will perform comprehensive testing of functionality, robustness, and reliability. The JRC, as an independent technical organization, will evaluate electrical safety and other environmental factors important to facility operator acceptance. The JRC is also able to simulate field trial conditions using equipment similar to what will be used in the field trial. DG-Energy will confirm the Sandia tests and also test the interface of the EDAS prototype to the RADAR data acquisition and analysis system used by the Euratom inspectorate. The EDAS prototypes will be tested in a comprehensive field trial at the Westinghouse Springfields facility in a collaboration between Euratom inspectors and the facility operator. The field trial will support barcode and weight measurements taken related to the movements of nuclear material items entering and exiting the facility. One EDAS prototype will branch barcode scanner data, while the other will branch facility weight scale data. The branched data will be sent securely to an inspector computer, accessible to a Euratom inspector for data analysis. The field trial will test operational factors and environmental conditions. A critical outcome will be to ascertain whether the inspectorate gains an accurate picture of the

  8. Current state and trend of radiation regulation system in Japan

    International Nuclear Information System (INIS)

    Yonehara, Hidenori

    2004-01-01

    Japanese regulation system for safety against radiation essentially started from 'Atomic Energy Basic Law' enacted in 1955 and 'Law Concerning Prevention of Radiation Hazards due to Radioisotopes, etc' enacted in 1957, has been regarded as a central rule for radiation protection and safety. Related laws and regulations have been enacted together with their revision. Radiation Council, established in the Science and Technology Agency in 1962 and now belonging to the Ministry of Education, Culture, Sports, Science and Technology, has deliberated basically on International Commission of Radiological Protection (ICRP) statements for legal revision and has set up working groups for current problems. Activities of the groups have concerned ICRP Publication 60 (1990) and later related publications for incorporating the principle into laws as to concepts of dose limits, effective dose, and then of exemption and exclusion. International status of the Japanese regulation, problems and tasks in the regulation are also commented. (N.I.)

  9. Impact of uniform electrode current distribution on ETF. [Engineering Test Facility MHD generator

    Science.gov (United States)

    Bents, D. J.

    1982-01-01

    A basic reason for the complexity and sheer volume of electrode consolidation hardware in the MHD ETF Powertrain system is the channel electrode current distribution, which is non-uniform. If the channel design is altered to provide uniform electrode current distribution, the amount of hardware required decreases considerably, but at the possible expense of degraded channel performance. This paper explains the design impacts on the ETF electrode consolidation network associated with uniform channel electrode current distribution, and presents the alternate consolidation designs which occur. They are compared to the baseline (non-uniform current) design with respect to performance, and hardware requirements. A rational basis is presented for comparing the requirements for the different designs and the savings that result from uniform current distribution. Performance and cost impacts upon the combined cycle plant are discussed.

  10. Molten Salt Test Loop (MSTL) system customer interface document.

    Energy Technology Data Exchange (ETDEWEB)

    Gill, David Dennis; Kolb, William J.; Briggs, Ronald D.

    2013-09-01

    The National Solar Thermal Test Facility at Sandia National Laboratories has a unique test capability called the Molten Salt Test Loop (MSTL) system. MSTL is a test capability that allows customers and researchers to test components in flowing, molten nitrate salt. The components tested can range from materials samples, to individual components such as flex hoses, ball joints, and valves, up to full solar collecting systems such as central receiver panels, parabolic troughs, or linear Fresnel systems. MSTL provides realistic conditions similar to a portion of a concentrating solar power facility. The facility currently uses 60/40 nitrate %E2%80%9Csolar salt%E2%80%9D and can circulate the salt at pressure up to 40 bar (600psi), temperature to 585%C2%B0C, and flow rate of 44-50kg/s(400-600GPM) depending on temperature. The purpose of this document is to provide a basis for customers to evaluate the applicability to their testing needs, and to provide an outline of expectations for conducting testing on MSTL. The document can serve as the basis for testing agreements including Work for Others (WFO) and Cooperative Research and Development Agreements (CRADA). While this document provides the basis for these agreements and describes some of the requirements for testing using MSTL and on the site at Sandia, the document is not sufficient by itself as a test agreement. The document, however, does provide customers with a uniform set of information to begin the test planning process.

  11. Development of high electrical resistance persistent current switch for high speed energization system

    International Nuclear Information System (INIS)

    Jizo, Y.; Furuta, Y.; Nakashima, H.

    1986-01-01

    Japanese National Railways is now developing a superconducting magnetically-levitated train system. A persistent current switch is incorporated in the super-conducting magnet used in the magnetically-levitated train. In recent years, the switch has been required to have higher electrical resistance during its off-state in order to realize the high speed energization/de-energization system of the superconducting magnets. The system aims to decrease evaporation volume of liquid helium during the energization/de-energization of the magnet, by means of energizing the superconducting magnet with high current increasing/decreasing rate. Consequently, it would be possible to decrease the dependence of the on-board magnet system upon the ground cooling system. Through the development of a stable superconductive wire material and a coil structure for the persistent current switch using many small model switches which were produced in order to improve their current carrying capacities, the authors have succeeded in manufacturing the high electrical resistance persistent current switch whose electrical resistance was 5 ohms. The switch, of cylindrical shape, has a diameter of about 100mm, a length of about 100mm. These 5 ohm PCSs are now functioning in stable conditions being incorporated in the superconducting magnets of No.2 vehicle of MLU001 at the JNR's Miyazaki test track. Further, the authors are now developing the PCS of still higher resistance values, such as 50 ohms, through studies for stabilization in structural aspects of the winding and obtaining results therefrom

  12. Double Retort System for Materials Compatibility Testing

    International Nuclear Information System (INIS)

    V. Munne; EV Carelli

    2006-01-01

    With Naval Reactors (NR) approval of the Naval Reactors Prime Contractor Team (NRPCT) recommendation to develop a gas cooled reactor directly coupled to a Brayton power conversion system as the Space Nuclear Power Plant (SNPP) for Project Prometheus (References a and b) there was a need to investigate compatibility between the various materials to be used throughout the SNPP. Of particular interest was the transport of interstitial impurities from the nickel-base superalloys, which were leading candidates for most of the piping and turbine components to the refractory metal alloys planned for use in the reactor core. This kind of contamination has the potential to affect the lifetime of the core materials. This letter provides technical information regarding the assembly and operation of a double retort materials compatibility testing system and initial experimental results. The use of a double retort system to test materials compatibility through the transfer of impurities from a source to a sink material is described here. The system has independent temperature control for both materials and is far less complex than closed loops. The system is described in detail and the results of three experiments are presented

  13. A method for crack sizing using Bayesian inference arising in eddy current testing

    International Nuclear Information System (INIS)

    Kojima, Fumio; Kikuchi, Mitsuhiro

    2008-01-01

    This paper is concerned with a sizing methodology of crack using Bayesian inference arising in eddy current testing. There is often uncertainty about data through quantitative measurements of nondestructive testing and this can yield misleading inference of crack sizing at on-site monitoring. In this paper, we propose optimal strategies of measurements in eddy current testing using Bayesian prior-to-posteriori analysis. First our likelihood functional is given by Gaussian distribution with the measurement model based on the hybrid use of finite and boundary element methods. Secondly, given a priori distributions of crack sizing, we propose a method for estimating the region of interest for sizing cracks. Finally an optimal sensing method is demonstrated using our idea. (author)

  14. Testing relativity with solar system dynamics

    Science.gov (United States)

    Hellings, R. W.

    1984-01-01

    A major breakthrough is described in the accuracy of Solar System dynamical tests of relativistic gravity. The breakthrough was achieved by factoring in ranging data from Viking Landers 1 and 2 from the surface of Mars. Other key data sources included optical transit circle observations, lunar laser ranging, planetary radar, and spacecraft (Mariner 9 to Mars and Mariner 10 to Mercury). The Solar System model which is used to fit the data and the process by which such fits are performed are explained and results are discussed. The results are fully consistent with the predictions of General Relativity.

  15. Waste retrieval sluicing system data acquisition system acceptance test report

    International Nuclear Information System (INIS)

    Bevins, R.R.

    1998-01-01

    This document describes the test procedure for the Project W-320 Tank C-106 Sluicing Data Acquisition System (W-320 DAS). The Software Test portion will test items identified in the WRSS DAS System Description (SD), HNF-2115. Traceability to HNF-2115 will be via a reference that follows in parenthesis, after the test section title. The Field Test portion will test sensor operability, analog to digital conversion, and alarm setpoints for field instrumentation. The W-320 DAS supplies data to assist thermal modeling of tanks 241-C-106 and 241-AY-102. It is designed to be a central repository for information from sources that would otherwise have to be read, recorded, and integrated manually. Thus, completion of the DAS requires communication with several different data collection devices and output to a usable PC data formats. This test procedure will demonstrate that the DAS functions as required by the project requirements stated in Section 3 of the W-320 DAS System Description, HNF-2115

  16. Influence of stabilizer thickness on over-current test of YBCO-coated conductors

    International Nuclear Information System (INIS)

    Kwon, N Y; Kim, H S; Kim, K L; Lee, H G; Yim, S W; Kim, H-R; Hyun, O-B; Kim, H M

    2009-01-01

    The increased use of distributed power generation has led to increasingly high fault current levels. A superconducting fault current limiter (SFCL) is a potential solution to prevent the problem of short-circuit currents. YBCO-coated conductors (CCs) are one of the most promising superconducting materials for SFCLs. Most YBCO CCs have stabilizers, which play a significant role in limiting the fault current in the SFCL. Therefore, the selection of the appropriate material and the thickness of the stabilizer of the CC used for the SFCL may affect its quench/recovery characteristics. In this paper, the quench/recovery characteristics of YBCO CC tapes having stabilizers with various thicknesses were investigated. The quench/recovery test results showed that, as the thickness of the stabilizer decreased, both the final approach temperature and the recovery time decreased.

  17. Tridimensional numerical modelling of an eddy current non destructive testing process

    International Nuclear Information System (INIS)

    Bonnin, O.; Chavant, C.; Giordano, P.

    1993-01-01

    This paper presents the numerical modelling of a new eddy current inspection process. The originality of the process, developed jointly by IFREMER and the CEA, lies in the mode of inducing the currents in the component to be tested. The TRIFOU eddy current calculation code is used for the modelling, which is in 3D. It is shown that a crack in the component inspected will cause localized disturbance of the currents induced. If we then focus on this disturbance, assuming the electrical behaviour of the materials to be linear, the resulting problem can be set for a limited geometrical area, leading to an appreciable saving in machine time. It is also shown that the computed and experimental results are quantitatively similar. (authors). 2 figs., 6 refs

  18. An advanced system for automated ultrasonic testing

    International Nuclear Information System (INIS)

    Dressler, K.

    1989-01-01

    As the main component of the AUP system, an ALOK ultrasonic unit has been chosen as it allows for testing of large component areas both search for defects and description of defect geometries. All data required for fault analysis can be obtained by one measuring run. For inspection of primary circuit components in nuclear power stations, the manipulator control and the ultrasonic probe are installed behind the first sufficient shielding. (orig./HP) [de

  19. Laboratory testing & measurement on optical imaging systems

    CSIR Research Space (South Africa)

    Theron, B

    2013-04-01

    Full Text Available on Optical Imaging Systems Bertus Theron 27 April 2013 presented at SIECPC 2013, Riyadh, Saudi Arabia Overview of Workshop Part 1. Introduction & Context  Some history of Arabic Optics  Context: Global vs Local optical testing... of Arabic Optics 1 See [4]  Arabic records of study of geometrical optics  Traced to Hellenistic (Greek) optics  Translated to Arabic  9th century  Arabic contribution to geometric optics  Not just translation to Arabic  Innovative research...

  20. New system for wiggler fabrication and testing

    International Nuclear Information System (INIS)

    Warren, R.W.; Elliott, C.J.

    1988-01-01

    A system approach is taken for fabrication and testing of wigglers for free-electron lasers. Emphasis is placed on convenient, practical, assembly procedures that produce wigglers with high fields, two-plane focusing, and facilities for in-place adjustments. Equal emphasis is placed on rapid and precise techniques for measuring field errors, both before final assembly and afterward, during wiggler operation. (author). 10 refs, 12 figs