WorldWideScience

Sample records for current study measured

  1. Current measurement studies around the Cesme Peninsula (Turkey)

    International Nuclear Information System (INIS)

    Taspinar, N.

    1989-04-01

    In order to design coastal structures and marine vehicles safely, it is required to know current climate which shows the variation of the current characteristics with time. There are a wide variety of current meters designed to measure water flow today. Each current meter is capable of recording the influence of mooring arrangement. Here we describe sea water temperatures, salinities and current velocities at offshore of Akburun, Tatlicak Burnu, Kalem Burnu and Kizil Burun areas in Cesme Peninsula 27 August, 1986 to 19 November, 1986. At the end of the investigations, measured significant maximum and average current velocities have been routinely analysed with micro-computers and also the percentages of current velocity have been calculated. (author). 8 refs, 6 figs, 4 tabs

  2. Modulated Current Drive Measurements

    International Nuclear Information System (INIS)

    Petty, C.C.; Lohr, J.; Luce, T.C.; Prater, R.; Cox, W.A.; Forest, C.B.; Jayakumar, R.J.; Makowski, M.A.

    2005-01-01

    A new measurement approach is presented which directly determines the noninductive current profile from the periodic response of the motional Stark effect (MSE) signals to the slow modulation of the external current drive source. A Fourier transform of the poloidal magnetic flux diffusion equation is used to analyze the MSE data. An example of this measurement technique is shown using modulated electron cyclotron current drive (ECCD) discharges from the DIII-D tokamak

  3. Dispersion and current measurements

    International Nuclear Information System (INIS)

    Boelskifte, S.

    1986-04-01

    A model for the simulation of particle movements in water should incorporate the mutual distance dependent correlation. As long as reliable data are given accessible a model can be created of the dispersion in a given area from a statistical description of turbulence. Current measurements have been performed in an area north of the Swedish nuclear power plant Barsebaeck, and statistical time series analysis have made it possible to estimate multivariate autoregressive moving-average (ARMA) models for these data using the Box-Jenkins method. The correlation structure for the area has been investigated in detail. Transport and dispersion models for the marine environment are used in estimating doses to the population from the aquatic food chain. Some of these models are described with special emphasis on the time and length scales they cover. Furthermore, to illustrate the background of the simulation model, short introductuions are given to health physics, time series analysis, and turbulence theory. Analysis of the simulation model shows the relative importance of the different parameters. The model can be expanded to conditional simulation, where the current measurements are used directly to simulate the movement of one of the particles. Results from the model are also compared to results from a sampling of bioindicators (Fucus vesiculosus) along the Danish coast. The reliability of bioindicators in this kind of experiment is discussed. (author)

  4. Temperature sensitivity study of eddy current and digital gauge probes for nuclear fuel rod oxide measurement

    Science.gov (United States)

    Beck, Faith R.; Lind, R. Paul; Smith, James A.

    2018-04-01

    Novel fuels are part of the nationwide effort to reduce the enrichment of Uranium for energy production. Performance of such fuels is determined by irradiating their surfaces. To test irradiated samples, the instrumentation must operate remotely. The plate checker used in this experiment at Idaho National Lab (INL) performs non-destructive testing on fuel rod and plate geometries with two different types of sensors: eddy current and digital thickness gauges. The sensors measure oxide growth and total sample thickness on research fuels, respectively. Sensor measurement accuracy is crucial because even 10 microns of error is significant when determining the viability of an experimental fuel. One parameter known to affect the eddy current and thickness gauge sensors is temperature. Since both sensor accuracies depend on the ambient temperature of the system, the plate checker has been characterized for these sensitivities. The manufacturer of the digital gauge probes has noted a rather large coefficient of thermal expansion for their linear scale. It should also be noted that the accuracy of the digital gauge probes are specified at 20°C, which is approximately 7°C cooler than the average hot-cell temperature. In this work, the effect of temperature on the eddy current and digital gauge probes is studied, and thickness measurements are given as empirical functions of temperature.

  5. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  6. Current-ripple effect on superconductive dc critical current measurements

    International Nuclear Information System (INIS)

    Goodrich, L.F.; Bray, S.L.; Clark, A.F.

    1988-01-01

    The effect of sample-current power-supply ripple on dc critical current measurement in multifilamentary NbTi superconductors was evaluated. In general the ripple in a current supply became more significant above 500 A because effective filtering was hard to achieve. Ripple also caused noise at the input of the voltmeter used for the measurements. The quantitative effect of current ripple was studied using a battery current supply modified to allow the creation of ripple current with variable frequency and amplitude. Problems common to all large-conductor critical current measurements are discussed

  7. Current/temperature measurements near the Sigsbee Escarpment from the MMS Desoto Canyon Intrusion Study, 19990829 - 20010906 (NODC Accession 0002569)

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — During this study in-situ measurement of currents,temperature, conductivity were made on a series of tautline moorings near the base of and on the Sigsbee...

  8. MSE measurements for sawtooth and non-inductive current drive studies in KSTAR

    Science.gov (United States)

    Ko, J.; Park, H.; Bea, Y. S.; Chung, J.; Jeon, Y. M.

    2016-10-01

    Two major topics where the measurement of the magnetic-field-line rotational transform profiles in toroidal plasma systems include the long-standing issue of complete versus incomplete reconnection model of the sawtooth instability and the issue with future reactor-relevant tokamak devices in which non-inductive steady state current sustainment is essential. The motional Stark effect (MSE) diagnostic based on the photoelastic-modulator (PEM) approach is one of the most reliable means to measure the internal magnetic pitch, and thus the rotational transform, or its reciprocal (q), profiles. The MSE system has been commissioned for the Korea Superconducting Tokamak Advanced Research (KSTAR) along with the development of various techniques to minimize systematic offset errors such as Faraday rotation and mis-alignment of the bandpass filters. The diagnostic has revealed the central q is well correlated with the sawtooth oscillation, maintaining its value above unity during the MHD quiescent period and that the response of the q profile to external current drive such as electron cyclotron wave injection not only involves the local change of the pitch angle gradient but also a significant shift of the magnetic topology due to the wave energy transport. Work supported by the Ministry of Science, ICT and Future Planning, Korea.

  9. Measurement of current distribution in a proton exchange membrane fuel cell with various flow arrangements – A parametric study

    International Nuclear Information System (INIS)

    Alaefour, Ibrahim; Karimi, G.; Jiao, Kui; Li, X.

    2012-01-01

    Highlights: ► Spatial local current distributions in a single PEMFC are measured. ► Effects of key operating conditions on the local current density are investigated. ► Increasing air and hydrogen stoichiometries improves local current density distributions. ► Operating pressure and temperature have negligible impact on local current distribution. - Abstract: Understanding of current distributions in proton exchange membrane fuel cells (PEMFCs) is crucial for designing cell components such as the flow field plates and the membrane electrode assembly (MEA). In this study, the spatial current density distributions in a single PEMFC with three serpentine flow channels are measured using a segmented bipolar plate and printed circuit board technique. The effects of key operating conditions such as stoichiometry ratios, inlet humidity levels, cell pressure and temperature on the local current density distributions for co-, counter-, and cross-flow arrangements are examined. It is observed that the local current density distribution over the MEA is directly affected by the cell operating conditions along with the configuration of the flow arrangement. It is also found that among the different flow configurations tested under the various operating conditions, the counter flow arrangement provides the optimum average current density and the lowest variations in the local current densities along the flow channels.

  10. Current Research Studies

    Science.gov (United States)

    ... Success Home > Explore Research > Current Research Studies Current Research Studies Email Print + Share The Crohn’s & Colitis Foundation ... conducted online. Learn more about IBD Partners. Clinical Research Alliance The Clinical Research Alliance is a network ...

  11. Dark Current Measurements in GIF++

    CERN Document Server

    Al-Qahtani, Abdulaziz

    2017-01-01

    This project revolved around creating a code that treats experiment files in order to fetch dark current measurements done for the Cathode Strip Chambers (CSC) exposed to long-term irradiation at Gamma Irradiation Facility (GIF++) and plot the results as functions of the accumulated charge. This paper will discuss the Compact Muon Solenoid (CMS) experiment, the CSCs that we have looked at (specifically the muon detectors located at the CMS endcaps), longevity test at GIF++, and finally discuss the code and results obtained.

  12. Measurement-based harmonic current modeling of mobile storage for power quality study in the distribution system

    Directory of Open Access Journals (Sweden)

    Wenge Christoph

    2017-12-01

    Full Text Available Electric vehicles (EVs can be utilized as mobile storages in a power system. The use of battery chargers can cause current harmonics in the supplied AC system. In order to analyze the impact of different EVs with regardto their number and their emission of current harmonics, a generic harmonic current model of EV types was built and implemented in the power system simulation tool PSS®NETOMAC. Based on the measurement data for different types of EVs three standardized harmonic EV models were developed and parametrized. Further, the identified harmonic models are used by the computation of load flow in a modeled, German power distribution system. As a benchmark, a case scenario was studied regarding a high market penetration of EVs in the year 2030 for Germany. The impact of the EV charging on the power distribution system was analyzed and evaluated with valid power quality standards.

  13. Study on the dynamic behavior of a current in cable-in-conduit conductors by using self magnetic field measurements

    Energy Technology Data Exchange (ETDEWEB)

    Obana, Tetsuhiro, E-mail: obana.tetsuhiro@LHD.nifs.ac.jp [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Takahata, Kazuya; Hamaguchi, Shinji; Imagawa, Shinsaku; Mito, Toshiyuki [National Institute for Fusion Science, 322-6 Oroshi, Toki 509-5292, Gifu (Japan); Kizu, Kaname; Murakami, Haruyuki; Yoshida, Kiyoshi [Japan Atomic Energy Agency, Ibaraki (Japan)

    2011-10-15

    In order to understand the current behavior inside a cable-in-conduit conductor (CICC), self magnetic field measurements on the CICC were conducted. A prototype NbTi CICC, the configuration of which is a racket shape, for JT-60SA EF coil was used as a short conductor sample. By using Hall sensors arranged around the short conductor sample, the variation in the self magnetic field was measured. Taking into account the measurements, the current behavior inside the CICC was analyzed by using analytical models consisting of line currents. The analytical results indicate that the current distribution in the cross-section of the CICC would be non-uniform before a normal propagation, and the current distribution would be improved after the normal propagation.

  14. Comparison of Measured and Estimated CT Organ Doses for Modulated and Fixed Tube Current:: A Human Cadaver Study.

    Science.gov (United States)

    Padole, Atul; Deedar Ali Khawaja, Ranish; Otrakji, Alexi; Zhang, Da; Liu, Bob; Xu, X George; Kalra, Mannudeep K

    2016-05-01

    The aim of this study was to compare the directly measured and the estimated computed tomography (CT) organ doses obtained from commercial radiation dose-tracking (RDT) software for CT performed with modulated tube current or automatic exposure control (AEC) technique and fixed tube current (mAs). With the institutional review board (IRB) approval, the ionization chambers were surgically implanted in a human cadaver (88 years old, male, 68 kg) in six locations such as liver, stomach, colon, left kidney, small intestine, and urinary bladder. The cadaver was scanned with routine abdomen pelvis protocol on a 128-slice, dual-source multidetector computed tomography (MDCT) scanner using both AEC and fixed mAs. The effective and quality reference mAs of 100, 200, and 300 were used for AEC and fixed mAs, respectively. Scanning was repeated three times for each setting, and measured and estimated organ doses (from RDT software) were recorded (N = 3*3*2 = 18). Mean CTDIvol for AEC and fixed mAs were 4, 8, 13 mGy and 7, 14, 21 mGy, respectively. The most estimated organ doses were significantly greater (P < 0.01) than the measured organ doses for both AEC and fixed mAs. At AEC, the mean estimated organ doses (for six organs) were 14.7 mGy compared to mean measured organ doses of 12.3 mGy. Similarly, at fixed mAs, the mean estimated organ doses (for six organs) were 24 mGy compared to measured organ doses of 22.3 mGy. The differences among the measured and estimated organ doses were higher for AEC technique compared to the fixed mAs for most organs (P < 0.01). The most CT organ doses estimated from RDT software are greater compared to directly measured organ doses, particularly when AEC technique is used for CT scanning. Copyright © 2016 The Association of University Radiologists. Published by Elsevier Inc. All rights reserved.

  15. Eddy currents in pulsed field measurements

    International Nuclear Information System (INIS)

    Kuepferling, M.; Groessinger, R.; Wimmer, A.; Taraba, M.; Scholz, W.

    2002-01-01

    Full text: One problem of pulsed field magnetometry is an error in magnetization, which appears in measurements of conducting samples. This error is due to eddy currents induced by a time varying field. To allow predictions how eddy currents exert influence on the hysteresis loop, systematic experimental and theoretical studies of pulsed field measurements of metallic samples were performed. The theoretical studies include analytical calculations as well as numerical ones using a 2D finite element software. In the measurements three physical parameters have been varied: i) the conductivity of the sample by using two different materials, in this case technical Cu and Al ii) size and shape of the sample by using cylinders, spheres and cuboids iii) the pulse duration of the external field by changing the capacitor battery from 8mF ( =9.1ms) to 24mF ( =15.7ms). The time dependence of the external field corresponds with a pulsed damped harmonic oscillation with a maximum value of 5.2T. The samples were studied in the as cast state (after machining) as well as after heat treatment. Theoretical calculations showed not only good agreement with the absolute values of the measured eddy current m agnetization , they also gave an explanation of the shape of the eddy current hysteresis and the dependence of the eddy current 'magnetization' on parameters as pulse duration of the external field and conductivity of the sample. (author)

  16. Current adaptation measures and policies

    Science.gov (United States)

    Geoff Roberts; John A. Parrotta; Anita. Wreford

    2009-01-01

    As stated in earlier chapters, the possible impacts of climate change on forests and the forest sector are considerable, and many impacts have already been observed. As forest conditions change, there is an inherent need to change management and policy measures to minimise negative impacts and to exploit the benefits derived from climate change. This chapter highlights...

  17. Measurement technology of RF interference current in high current system

    Science.gov (United States)

    Zhao, Zhihua; Li, Jianxuan; Zhang, Xiangming; Zhang, Lei

    2018-06-01

    Current probe is a detection method commonly used in electromagnetic compatibility. With the development of power electronics technology, the power level of power conversion devices is constantly increasing, and the power current of the electric energy conversion device in the electromagnetic launch system can reach 10kA. Current probe conventionally used in EMC (electromagnetic compatibility) detection cannot meet the test requirements on high current system due to the magnetic saturation problem. The conventional high current sensor is also not suitable for the RF (Radio Frequency) interference current measurement in high current power device due to the high noise level in the output of active amplifier. In this paper, a passive flexible current probe based on Rogowski coil and matching resistance is proposed that can withstand high current and has low noise level, to solve the measurement problems of interference current in high current power converter. And both differential mode and common mode current detection can be easily carried out with the proposed probe because of the probe's flexible structure.

  18. Cryogenic current comparators for precise ion beam current measurements

    International Nuclear Information System (INIS)

    Kurian, Febin

    2015-01-01

    The planned Facility for Antiproton and Ion Research (FAIR) at GSI has to cope with a wide range of beam intensities in its high-energy beam transport systems and in the storage rings. To meet the requirements of a non-intercepting intensity measurement down to nA range, it is planned to install a number of Cryogenic Current Comparator (CCC) units at different locations in the FAIR beamlines. In this work, the first CCC system for intensity measurement of heavy ion beams, which was developed at GSI, was re-commissioned and upgraded to be used as a 'GSI - CCC prototype' for extensive optimization and development of an improved CCC for FAIR. After installation of a new SQUID sensor and related electronics, as well as implementation of improved data acquisition components, successful beam current measurements were performed at a SIS18 extraction line. The measured intensity values were compared with those of a Secondary Electron Monitor (SEM). Furthermore, the spill-structure of a slowly extracted beam was measured and analyzed, investigating its improvement due to bunching during the slow-extraction process. Due to the extreme sensitivity of the superconducting sensor, the determined intensity values as well as the adjustment of the system for optimal performance are strongly influenced by the numerous noise sources of the accelerators environment. For this reason, detailed studies of different effects caused by noise have been carried out, which are presented together with proposals to reduce them. Similarly, studies were performed to increase the dynamic range and overcome slew rate limitations, the results of which are illustrated and discussed as well. By combining the various optimizations and characterizations of the GSI CCC prototype with the experiences made during beam operation, criteria for a more efficient CCC System could be worked out, which are presented in this work. The details of this new design are worked out with respect to the

  19. High current density ion beam measurement techniques

    International Nuclear Information System (INIS)

    Ko, W.C.; Sawatzky, E.

    1976-01-01

    High ion beam current measurements are difficult due to the presence of the secondary particles and beam neutralization. For long Faraday cages, true current can be obtained only by negative bias on the target and by summing the cage wall and target currents; otherwise, the beam will be greatly distorted. For short Faraday cages, a combination of small magnetic field and the negative target bias results in correct beam current. Either component alone does not give true current

  20. Measuring Electrical Current: The Roads Not Taken

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2011-01-01

    Recently I wrote about the standard Weston meter movement, that is at the heart of all modern analogue current measurements. Now I will discuss other techniques used to measure electric current that, despite being based on valid physical principles, are largely lost in technological history.

  1. Fast measure proceeding of weak currents

    International Nuclear Information System (INIS)

    Taieb, J.

    1953-01-01

    The process of fast measure of the weak currents that we are going to describe briefly apply worthy of the provided currents by the sources to elevated value internal resistance, as it is the case for the ionization chamber, the photocells, mass spectroscopic tubes. The problem to measure weak currents is essentially a problem of amplifier and of input circuit. We intended to achieve a whole amplifier and input circuit with advanced performances, meaning that for a measured celerity we wanted to have an signal/noise ratio the most important as in the classic systems and for a same report signal/noise a more quickly done measure. (M.B.) [fr

  2. High-current railgap studies

    Energy Technology Data Exchange (ETDEWEB)

    Druce, R.; Gordon, L.; Hofer, W.; Wilson, M.

    1983-06-03

    Characteristics of a 40-kV, 750-kA, multichannel rail gap are presented. The gap is a three electrode, field-distortion-triggered design, with a total switch inductance of less than 10 nH. At maximum ratings, the gap typically switches 10 C per shot, at 700 kA, with a jitter of less than 2 ns. Image-converter streak photographs were used to study channel evolution and current division. Transient gas-pressure measurements were made to investigate the arc generated shocks and to detect single channel failure. Channel current sharing and simultaneity are described and their effects on the switch inductance and lifetime are discussed. Lifetime tests of the rail gap were performed. Degradation in the channel current-sharing and erosion measurements are discussed.

  3. High-current railgap studies

    Science.gov (United States)

    Druce, R.; Gordon, L.; Hofer, W.; Wilson, M.

    1983-06-01

    Characteristics of a 40-kV, 750-kA, multichannel rail gap are presented. The gap is a three electrode, field distortion triggered design, with a total switch inductance of less than 10 nH. At maximum ratings, the gap typically switches 10 C per shot, at 700 kA, with a jitter of less than 2 ns. Channel evolution and current division were studied on image converter streak photographs. Transient gas pressure measurements were made to investigate the arc generated shocks and to detect single channel failure. Channel current sharing and simultaneity are described and their effects on the switch inductance in the channel current sharing and erosion measurements are discussed.

  4. Local eddy current measurements in pulsed fields

    Energy Technology Data Exchange (ETDEWEB)

    Espina-Hernandez, J.H. [SEPI-Electronica, ESIME-IPN, UPALM Edif. ' Z' . Zacatenco, Mexico DF 07738 (Mexico)], E-mail: jhespina@gmail.com; Groessinger, R. [Institute of Solid State Physics, Vienna University of Technology, Wiedner Hauptstrasse 8-10, A-1040 Vienna (Austria); Hallen, J.M. [Departamento de Ingenieria Metalurgica, IPN-ESIQIE, UPALM Edif. 7, Zacatenco, Mexico DF 07738 (Mexico)

    2008-07-15

    This work presents new eddy current measurements in pulsed fields. A commercial point pick-up coil is used to detect the induction signal along the radius of Cu and Al samples with cylindrical shape and diameters between 5 and 35 mm. Local eddy current measurements were performed on the surface of conducting materials due to the small dimensions of the coil. A simple electrical circuit, used as a model, is proposed to describe the local eddy current effect in pulsed fields. The proposed model allows to calculate the phase shift angle between the signal proportional to eddy currents and the applied external field in a pulsed field magnetometer.

  5. Zero current measurements using the Rogowski coil

    International Nuclear Information System (INIS)

    Gregor, J.; Jakubova, I.; Kadlec, P.; Senk, J.; Vavra, Z.

    1997-01-01

    The zero current measurements using the Rogowski coil carried out on the model of the extinguishing chamber of hv SF 6 circuit breaker with self-flow generation are presented in the paper. The time course of the post-arc current obtained by numerical integration of the measured induced voltage of the Rogowski coil gives information not only about the value of the residual current after the successful interruption but also about the current changes connected with the dynamic behaviour of the arc during its quenching. (author)

  6. Are objective measures of tricuspid annular motion and velocity used as frequently as recommended by current guidelines? A pilot study

    Directory of Open Access Journals (Sweden)

    Angel López-Candales

    2018-03-01

    Full Text Available In this retrospective study 420 echocardiograms from a single center were reviewed showing that TAPSE was acquired in 66% while TA TDI s’ signals were recorded in 98% of all echocardiograms. Based on these results greater efforts are required to standardize acquisition and reporting of objective measurements of RV function. Keywords: Echocardiography, Right ventricular dysfunction, TAPSE, Tricuspid annulus, M-mode, Tissue doppler imaging

  7. Continuous measurement of an atomic current

    Science.gov (United States)

    Laflamme, C.; Yang, D.; Zoller, P.

    2017-04-01

    We are interested in dynamics of quantum many-body systems under continuous observation, and its physical realizations involving cold atoms in lattices. In the present work we focus on continuous measurement of atomic currents in lattice models, including the Hubbard model. We describe a Cavity QED setup, where measurement of a homodyne current provides a faithful representation of the atomic current as a function of time. We employ the quantum optical description in terms of a diffusive stochastic Schrödinger equation to follow the time evolution of the atomic system conditional to observing a given homodyne current trajectory, thus accounting for the competition between the Hamiltonian evolution and measurement back action. As an illustration, we discuss minimal models of atomic dynamics and continuous current measurement on rings with synthetic gauge fields, involving both real space and synthetic dimension lattices (represented by internal atomic states). Finally, by "not reading" the current measurements the time evolution of the atomic system is governed by a master equation, where—depending on the microscopic details of our CQED setups—we effectively engineer a current coupling of our system to a quantum reservoir. This provides interesting scenarios of dissipative dynamics generating "dark" pure quantum many-body states.

  8. Sensitive beam current measurement for FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Schwickert, Marcus; Kurian, Febin; Reeg, Hansjoerg [GSI Helmholtzzentrum fuer Schwerionenforschung GmbH, Darmstadt (Germany); Seidel, Paul; Neubert, Ralf [Friedrich-Schiller-Universitaet Jena (Germany); Geithner, Rene; Vodel, Wolfgang [Helmholtz-Institut Jena (Germany)

    2012-07-01

    Presently FAIR, the Facility for Antiproton and Ion Research, entered the final planning phase at GSI. The new accelerator facility requires precise devices for beam current measurements due to the large dynamics in beam intensities for the various synchrotrons, transport lines and storage rings. We report on the actual developments of beam diagnostic devices for the measurement of beam intensities ranging from 5 x 10{sup 11} uranium ions down to the detection of less than 10{sup 4} antiprotons. This contribution gives an overview of the planned instruments with a focus on non-intercepting beam current transformers, and summarizes the on-going development of a cryogenic current comparator.

  9. Automatic system for ionization chamber current measurements

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro S.; Koskinas, Marina F.

    2004-01-01

    The present work describes an automatic system developed for current integration measurements at the Laboratorio de Metrologia Nuclear of Instituto de Pesquisas Energeticas e Nucleares. This system includes software (graphic user interface and control) and a module connected to a microcomputer, by means of a commercial data acquisition card. Measurements were performed in order to check the performance and for validating the proposed design

  10. Current practice of usual clinic blood pressure measurement in people with and without diabetes: a survey and prospective 'mystery shopper' study in UK primary care.

    Science.gov (United States)

    Stevens, Sarah L; McManus, Richard J; Stevens, Richard John

    2018-04-12

    Hypertension trials and epidemiological studies use multiple clinic blood pressure (BP) measurements at each visit. Repeat measurement is also recommended in international guidance; however, little is known about how BP is measured routinely. This is important for individual patient management and because routinely recorded readings form part of research databases. We aimed to determine the current practice of BP measurement during routine general practice appointments. (1) An online cross-sectional survey and (2) a prospective 'mystery shopper' study where patients agreed to report how BP was measured during their next appointment. Primary care. Patient charity/involvement group members completing an online survey between July 2015 and January 2016. 334 participants completed the prospective study (51.5% male, mean age=59.3 years) of which 279 (83.5%) had diabetes. Proportion of patients having BP measured according to guidelines. 217 participants with (183) and without diabetes (34) had their BP measured at their last appointment. BP was measured in line with UK guidance in 63.7% and 60.0% of participants with and without diabetes, respectively. Initial pressures were significantly higher in those who had their BP measured more than once compared with only once (p=0.016/0.089 systolic and p<0.001/p=0.022 diastolic, in patients with/without diabetes, respectively). Current practice of routine BP measurement in UK primary care is often concordant with guidelines for repeat measurement. Further studies are required to confirm findings in broader populations, to confirm when a third repeat reading is obtained routinely and to assess adherence to other aspects of BP measurement guidance. © Article author(s) (or their employer(s) unless otherwise stated in the text of the article) 2018. All rights reserved. No commercial use is permitted unless otherwise expressly granted.

  11. Leakage current measurement in transformerless PV inverters

    DEFF Research Database (Denmark)

    Kerekes, Tamas; Sera, Dezso; Mathe, Laszlo

    2012-01-01

    Photovoltaic (PV) installations have seen a huge increase during the last couple of years. Transformerless PV inverters are gaining more share of the total inverter market, due to their high conversion efficiency, small weight and size. Nevertheless safety should have an important role in case...... of these tranformerless systems, due to the missing galvanic isolation. Leakage and fault current measurement is a key issue for these inverter topologies to be able to comply with the required safety standards. This article presents the test results of two different current measurement sensors that were suggested...

  12. Multichannel measuring instrument of small currents

    International Nuclear Information System (INIS)

    Kunetsov, A.N.; Kuznetsov, E.A.

    2009-01-01

    The device intended for display of a profile of an ion beam by measurement of currents of the co-ordinate wires is developed. Technical characteristics, basic electric and logic schemes, time diagrams, and also photos of the basic parts of the device are presented

  13. Concurrent Validity and Feasibility of Short Tests Currently Used to Measure Early Childhood Development in Large Scale Studies.

    Directory of Open Access Journals (Sweden)

    Marta Rubio-Codina

    Full Text Available In low- and middle-income countries (LIMCs, measuring early childhood development (ECD with standard tests in large scale surveys and evaluations of interventions is difficult and expensive. Multi-dimensional screeners and single-domain tests ('short tests' are frequently used as alternatives. However, their validity in these circumstances is unknown. We examined the feasibility, reliability, and concurrent validity of three multi-dimensional screeners (Ages and Stages Questionnaires (ASQ-3, Denver Developmental Screening Test (Denver-II, Battelle Developmental Inventory screener (BDI-2 and two single-domain tests (MacArthur-Bates Short-Forms (SFI and SFII, WHO Motor Milestones (WHO-Motor in 1,311 children 6-42 months in Bogota, Colombia. The scores were compared with those on the Bayley Scales of Infant and Toddler Development (Bayley-III, taken as the 'gold standard'. The Bayley-III was given at a center by psychologists; whereas the short tests were administered in the home by interviewers, as in a survey setting. Findings indicated good internal validity of all short tests except the ASQ-3. The BDI-2 took long to administer and was expensive, while the single-domain tests were quickest and cheapest and the Denver-II and ASQ-3 were intermediate. Concurrent validity of the multi-dimensional tests' cognitive, language, and fine motor scales with the corresponding Bayley-III scale was low below 19 months. However, it increased with age, becoming moderate-to-high over 30 months. In contrast, gross motor scales' concurrence was high under 19 months and then decreased. Of the single-domain tests, the WHO-Motor had high validity with gross motor under 16 months, and the SFI and SFII expressive scales showed moderate correlations with language under 30 months. Overall, the Denver-II was the most feasible and valid multi-dimensional test and the ASQ-3 performed poorly under 31 months. By domain, gross motor development had the highest concurrence

  14. A quality assurance study on the accuracy of measuring physical function under current conditions for use of clinical video telehealth.

    Science.gov (United States)

    Hoenig, Helen; Tate, Latoya; Dumbleton, Sarina; Montgomery, Christy; Morgan, Michelle; Landerman, Lawrence R; Caves, Kevin

    2013-05-01

    To determine whether conditions for use of clinical video telehealth technology might affect the accuracy of measures of physical function. Repeated measures. Veterans Administration Medical Center. Three healthy adult volunteers for a sample size of n=30 independent trials for each of 3 physical function tasks. None. Three tasks capturing differing aspects of physical function: fine-motor coordination (number of finger taps in 30s), gross-motor coordination (number of gait deviations in 10ft [3.05m]), and clinical spatial relations (identifying the proper height for a cane randomly preset ±0-2in [5.1cm] from optimal), with performance simultaneously assessed in person and video recorded. Interrater reliability and criterion validity were determined for the measurement of these 3 tasks scored according to 5 methods: (1) in person (community standard), (2) slow motion review of the video recording (criterion standard), and (3-5) full speed review at 3 Internet bandwidths (64kps, 384kps, and 768kps). Fine-motor coordination-Interrater reliability was variable (r=.43-.81) and criterion validity was poor at 64kps and 384kps, but both were acceptable at 768kps (reliability r=.74, validity β=.81). Gross-motor coordination-Interreliability was variable (range r=.53-.75) and criterion validity was poor at all bandwidths (β=.28-.47). Motionless spatial relations-Excellent reliability (r=.92-.97) and good criterion validity (β=.84-.89) at all the tested bandwidths. Internet bandwidth had differing effects on measurement validity and reliability for the fine-motor task, the gross-motor task, and spatial relations, with results for some tasks at some transmission speeds well below acceptable quality standards and community standards. Copyright © 2013 American Congress of Rehabilitation Medicine. Published by Elsevier Inc. All rights reserved.

  15. Logarithmic current-measuring transistor circuits

    DEFF Research Database (Denmark)

    Højberg, Kristian Søe

    1967-01-01

    Describes two transistorized circuits for the logarithmic measurement of small currents suitable for nuclear reactor instrumentation. The logarithmic element is applied in the feedback path of an amplifier, and only one dual transistor is used as logarithmic diode and temperature compensating...... transistor. A simple one-amplifier circuit is compared with a two-amplifier system. The circuits presented have been developed in connexion with an amplifier using a dual m.o.s. transistor input stage with diode-protected gates....

  16. Microstructure cantilever beam for current measurement

    Directory of Open Access Journals (Sweden)

    M.T.E. Khan

    2010-01-01

    Full Text Available Most microelectromechanical systems (MEMS sensors are based on the microcantilever technology, which uses a broad range of design materials and structures. The benefit ofMEMStechnology is in developing devices with a lower cost, lower power consumption, higher performance and greater integration. A free-end cantilever beam with a magnetic material mass has been designed using MEMS software tools. The magnetic material was used to improve the sensitivity of the cantilever beam to an externally-applied magnetic field. The cantilever was designed to form a capacitance transducer, which consisted of variable capacitance where electrical and mechanical energies were exchanged. The aim of this paper was to analyse the system design of the microcantilever when subjected to a magnetic field produced by a current-carrying conductor. When the signal, a sinusoidal current with a constant frequency, was applied, the cantilever beam exhibited a vibration motion along the vertical axis when placed closer to the line current. This motion created corresponding capacitance changes and generated a voltage output proportional to the capacitive change in the signal-processing circuitry attached to the microcantilever. The equivalent massspring system theory was used to describe and analyse the effect of the natural frequency of the system vibrations and motion due to the applied magnetic field, in a single-degree of freedom. The main application of this microcantilever is in current measurements to develop a non-contact current sensor mote.

  17. A study of the rebound effect on China's current energy conservation and emissions reduction: Measures and policy choices

    International Nuclear Information System (INIS)

    Lin, Boqiang; Yang, Fang; Liu, Xia

    2013-01-01

    Energy efficiency improvement leads to a reduction in the real cost of energy services per unit, thus bringing about an increase in the demand for energy services. Therefore, the potential energy savings and emission reduction from efficiency improvements might be offset, which is known as “the rebound effect”. This study disaggregates the effect into the direct and indirect effects based on the Slutsky Equation and finds that the rebound effect of Chinese urban households is approximately 22%. It is found that the indirect effect is stronger than the direct effect. These findings prove that the initial goals of the government on energy conservation and emission reduction could not be achieved by improving energy efficiency alone, but need to be supplemented with relevant energy pricing reforms. - Highlights: • This study disaggregates the effect into the direct and indirect effects. • The rebound effect of Chinese urban households is approximately 22%. • The indirect effect is stronger than the direct effect. • Energy pricing reform is needed to mitigate the rebound effect

  18. SQUID based cryogenic current comparator for measurements of the dark current of superconducting cavities

    Energy Technology Data Exchange (ETDEWEB)

    Vodel, W.; Nietzsche, S.; Neubert, R.; Nawrodt, R. [Friedrich Schiller Univ. Jena (Germany); Peters, A. [GSI Darmstadt (Germany); Knaack, K.; Wendt, M.; Wittenburg, K. [DESY Hamburg (Germany)

    2005-07-01

    The linear accelerator technology, based on super-conducting L-band (1.3 GHz) is currently under study at DESY (Hamburg, Germany). The two 10 km long main Linacs will be equipped with a total of nearly 20.000 cavities. The dark current due to the emission of electrons in these high gradient field super-conducting cavities is an unwanted particle source. A newly high performance SQUID based measurement system for detecting dark currents is proposed. It makes use of the Cryogenic Current Comparator principle and senses dark currents in the pA range with a measurement bandwidth of up to 70 kHz. The use of a cryogenic current comparator as dark current sensor has some important advantages: -) the measurement of the absolute value of the dark current, -) the non-dependence on the electron trajectories, -) the accurate absolute calibration with an additional wire loop, and -) extremely high resolution.

  19. Fluxgate Magnetic Sensor and Its Application for Current Measurement

    International Nuclear Information System (INIS)

    Mitra-Djamal

    2007-01-01

    Conventionally electric current can be measured by connecting the instrument serially on the circuit. This method has disadvantage because its disturb the measured current flow. By using a magnetic sensor, current can be measured without disturbing the current flow, because it just measures the magnetic field of the measured current. This paper shows the use of fluxgate magnetic sensor for current measurement. It is shown that the sensor can measure widely range of current with resolution ≤ 2 %. (author)

  20. Experimental study of neoclassical currents

    International Nuclear Information System (INIS)

    Zarnstorff, M.C.; Prager, S.C.

    1985-05-01

    A detailed experimental study is presented of the bootstrap and Pfirsch-Schlueter currents that are predicted by neoclassical transport theory. In a toroidal octupole, on magnetic surfaces within the separatrix, the observed parallel plasma currents are in excellent quantitative agreement with neoclassical theory with regard to the spatial structure (along a magnetic surface), collisionality dependence and toroidal magnetic field dependence. On magnetic surfaces outside the separatrix, the ion portion of the parallel current is in agreement with neoclassical theory but the electron parallel current is observed to obtain a unidirectional component which deviates from and exceeds the theoretical prediction

  1. A comprehensive study of charge trapping in organic field-effect devices with promising semiconductors and different contact metals by displacement current measurements

    International Nuclear Information System (INIS)

    Bisoyi, Sibani; Tiwari, Shree Prakash; Rödel, Reinhold; Zschieschang, Ute; Klauk, Hagen; Kang, Myeong Jin; Takimiya, Kazuo

    2016-01-01

    A systematic and comprehensive study on the charge-carrier injection and trapping behavior was performed using displacement current measurements in long-channel capacitors based on four promising small-molecule organic semiconductors (pentacene, DNTT, C 10 -DNTT and DPh-DNTT). In thin-film transistors, these semiconductors showed charge-carrier mobilities ranging from 1.0 to 7.8 cm 2 V −1 s −1 . The number of charges injected into and extracted from the semiconductor and the density of charges trapped in the device during each measurement were calculated from the displacement current characteristics and it was found that the density of trapped charges is very similar in all devices and of the order 10 12 cm −2 , despite the fact that the four semiconductors show significantly different charge-carrier mobilities. The choice of the contact metal (Au, Ag, Cu, Pd) was also found to have no significant effect on the trapping behavior. (paper)

  2. Current Measurements and Overwash Monitoring Using Tilt Current Meters in Three Coastal Environments

    Science.gov (United States)

    Lowell, N. S.; Sherwood, C. R.; Decarlo, T. M.; Grant, J. R.

    2014-12-01

    Tilt Current Meters (TCMs) provide accurate, cost effective measurements of near-bottom current velocities. Many studies in coastal environments require current measurements, which are frequently made with Acoustic Doppler Profilers (ADPs). ADPs are expensive, however, and may not be suitable for locations where there is significant risk of damage, loss, or theft or where a large spatial array of measurements is required. TCMs, by contrast, are smaller, less expensive, and easier to deploy. This study tested TCMs in three sites to determine their suitability for use in research applications. TCMs are based on the drag-tilt principle, where the instrument tilts in response to current. The meter consists of a buoyant float with an onboard accelerometer, three-axis tilt sensor, three-axis magnetometer (compass), and a data logger. Current measurements are derived by post processing the tilt and compass values and converting them to velocity using empirical calibration data. Large data-storage capacity (4 GB) and low power requirements allow long deployments (many months) at high sample rates (16 Hz). We demonstrate the utility of TCM current measurements on a reef at Dongsha Atoll in the South China Sea, and in Vineyard Sound off Cape Cod, where the TCM performance was evaluated against ADP measurements. We have also used the TCM to record waves during an overwash event on a Cape Cod barrier beach during a winter storm. The TCM recorded waves as they came through the overwash channel, and the data were in agreement with the water-level record used as a reference. These tests demonstrate that TCMs may be used in a variety of near shore environments and have the potential to significantly increase the density of meters in future studies were current measurements are required.

  3. Current wheeze, asthma, respiratory infections, and rhinitis among adults in relation to inspection data and indoor measurements in single-family houses in Sweden-The BETSI study.

    Science.gov (United States)

    Wang, J; Engvall, K; Smedje, G; Nilsson, H; Norbäck, D

    2017-07-01

    In the Swedish Building Energy, Technical Status and Indoor environment study, a total of 1160 adults from 605 single-family houses answered a questionnaire on respiratory health. Building inspectors investigated the homes and measured temperature, air humidity, air exchange rate, and wood moisture content (in attic and crawl space). Moisture load was calculated as the difference between indoor and outdoor absolute humidity. Totally, 7.3% were smokers, 8.7% had doctor' diagnosed asthma, 11.2% current wheeze, and 9.5% current asthma symptoms. Totally, 50.3% had respiratory infections and 26.0% rhinitis. The mean air exchange rate was 0.36/h, and the mean moisture load 1.70 g/m 3 . Damp foundation (OR=1.79, 95% CI 1.16-2.78) was positively associated while floor constructions with crawl space (OR=0.49, 95% CI 0.29-0.84) was negatively associated with wheeze. Concrete slabs with overlying insulation (OR=2.21, 95% CI 1.24-3.92) and brick façade (OR=1.71, 95% CI 1.07-2.73) were associated with rhinitis. Moisture load was associated with respiratory infections (OR=1.21 per 1 g/m 3 , 95% CI 1.04-1.40) and rhinitis (OR=1.36 per 1 g/m 3 , 95% CI 1.02-1.83). Air exchange rate was associated with current asthma symptoms (OR=0.85 per 0.1/h, 95% CI 0.73-0.99). Living in homes with damp foundation, concrete slabs with overlying insulation, brick façade, low ventilation flow, and high moisture load are risk factors for asthma, rhinitis, and respiratory infections. © 2016 John Wiley & Sons A/S. Published by John Wiley & Sons Ltd.

  4. Development of a six channel Fabry-Perot interferometer for continuous measurement of electron temperature of Tokamak plasma. Application to current diffusion study

    International Nuclear Information System (INIS)

    Talvard, M.

    1984-10-01

    It is shown how the properties of the electron cyclotron emission of a tokamak plasma can be used to measure the electron temperature. The design of a six channel Fabry-Perot interferometer is then described. This interferometer allows the measurement of the time evolution of the electron temperature profile of the plasma in the TFR tokamak. Using this technique interesting results have been obtained concerning the current penetration during the start up phase of a tokamak discharge [fr

  5. Anodal Transcranial Direct Current Stimulation Shows Minimal, Measure-Specific Effects on Dynamic Postural Control in Young and Older Adults: A Double Blind, Sham-Controlled Study.

    Science.gov (United States)

    Craig, Chesney E; Doumas, Michail

    2017-01-01

    We investigated whether stimulating the cerebellum and primary motor cortex (M1) using transcranial direct current stimulation (tDCS) could affect postural control in young and older adults. tDCS was employed using a double-blind, sham-controlled design, in which young (aged 18-35) and older adults (aged 65+) were assessed over three sessions, one for each stimulatory condition-M1, cerebellar and sham. The effect of tDCS on postural control was assessed using a sway-referencing paradigm, which induced platform rotations in proportion to the participant's body sway, thus assessing sensory reweighting processes. Task difficulty was manipulated so that young adults experienced a support surface that was twice as compliant as that of older adults, in order to minimise baseline age differences in postural sway. Effects of tDCS on postural control were assessed during, immediately after and 30 minutes after tDCS. Additionally, the effect of tDCS on corticospinal excitability was measured by evaluating motor evoked potentials using transcranial magnetic stimulation immediately after and 30 minutes after tDCS. Minimal effects of tDCS on postural control were found in the eyes open condition only, and this was dependent on the measure assessed and age group. For young adults, stimulation had only offline effects, as cerebellar stimulation showed higher mean power frequency (MPF) of sway 30 minutes after stimulation. For older adults, both stimulation conditions delayed the increase in sway amplitude witnessed between blocks one and two until stimulation was no longer active. In conclusion, despite tDCS' growing popularity, we would caution researchers to consider carefully the type of measures assessed and the groups targeted in tDCS studies of postural control.

  6. Circuit for current measures from ionization chambers

    International Nuclear Information System (INIS)

    Mello, F.L.V. de; Oliveira, A.H. de; Rezende, R.S.

    1992-01-01

    The design and the specifications of an ammeters of low cost for small current, IOE-14 Ampere, from ionization chambers or others transducers used in nuclear instrumentation are described. Special attention is given to the integrated electronic components, available in the brazilian market. (C.G.C.)

  7. Study of longshore current equations for currents in Visakhapatnam beach

    Digital Repository Service at National Institute of Oceanography (India)

    Chandramohan, P.; Rao, T.V.N.

    Longshore currents were measured along the Visakhapatnam Beach, Andhra Pradesh, India at weekly intervals from March 1978 to March 1979. Visual observations on breaker characteristics were also made during this period. Using modified Longuet...

  8. Wave measurement in severe ocean currents

    Digital Repository Service at National Institute of Oceanography (India)

    Diwan, S.G.; Suryavanshi, A.K.; Nayak, B.U.

    The measurement of ocean waves has been of particular interest, as wave data and understanding of wave phenomena are essential to ocean engineering, coastal engineering and to many marine operations. The National Institute of Oceanography, Goa...

  9. Digital DC beam current measurement on SSRF storage ring

    International Nuclear Information System (INIS)

    Xiong Liang; Yin Chongxian; Liu Ming; Chen Jianfeng

    2011-01-01

    Both DC current transformer (DCCT) and integrating current transformer (ICT) can be used in DC beam current measurement. The ICT has strong capability of resisting electromagnetic interference, but its measurement accuracy cannot satisfy the DC beam current measurement requirement when using traditional high speed A/D. With high resolution A/D and equivalent sampling system, DC beam current measuring system based on ICT can reach high accuracy compared with DCCT system. In this paper, the ICT-based DC beam current measurement, equivalent sampling method and testing results at Shanghai Synchrotron Radiation Facility(SSRF) is described. (authors)

  10. Current measurement method for characterization of fast switching power semiconductors with Silicon Steel Current Transformer

    DEFF Research Database (Denmark)

    Li, Helong; Beczkowski, Szymon; Munk-Nielsen, Stig

    2015-01-01

    This paper proposes a novel current measurement method with Silicon Steel Current Transformer (SSCT) for the characterization of fast switching power semiconductors. First, the existing current sensors for characterization of fast switching power semiconductors are experimentally evaluated...

  11. Study of complex resistivity measurement using current and potential waveform data; Denryu to den`i hakei data wo riyoshita fukusohi teiko sokutei no kento

    Energy Technology Data Exchange (ETDEWEB)

    Shima, H; Sakurai, K; Yamashita, Y [OYO Corp., Tokyo (Japan)

    1997-10-22

    This paper proposes a measurement method for complex resistivity using both current and potential waveforms. This method was applied to actual data. Especially, chargeability was discussed among complex resistivities. A method was proposed for determining the complex resistivity. At first, digital measurements of both current and potential waveforms were conducted. For the potential waveform, zero-order self-potential was canceled. Then, the FFT technique was applied to both current and potential waveforms, to determine both current and potential in the frequency domain. Hereafter, complex resistivity was determined through simple division. Since the inductive coupling was observed at higher frequencies, it was difficult to apply Cole-Cole model, simply. However, the inductive coupling could be removed using proper sampling frequency. Thus, a proper Cole-Cole dispersion curve could be obtained. Using this Cole-Cole dispersion curve, new chargeability could be defined. A linear relation between this chargeability and the ordinary time domain chargeability was made clear. 4 refs., 10 figs.

  12. Study of critical current density from ac susceptibility measurements in (La1-xYx)2Ba2CaCu5O2 superconductors

    International Nuclear Information System (INIS)

    Nayak, P.K.; Ravi, S. . sravi@iitg.ernet.in

    2008-01-01

    We have prepared a series of compounds (La 1-x Y x ) 2 Ba 2 CaCu 5 O 2 for x = 0 to 0.5 by adding a CaCuO 2 layer to the parent compound La 2 Ba 2 Cu 4 O 2 and by doping Y in place of La. These materials are also prepared by adding 5 wt% of Ag to enhance the intergranular coupling and critical current density. X-ray diffraction measurements show that all the samples are essentially in single phase form and the patterns could be refined using P4/mmm space group in tetragonal cell. The typical lattice parameters are found to be a = b 3.856 A, c = 11.576 A for x = 0.5 sample. Temperature variations of dc electrical resistivity measured on the above samples show that they exhibit superconductivity with T c ranging from 60 to 75 K. Temperature and ac field amplitude variation of ac susceptibility have been measured on the above samples. The field variation of ac susceptibility data has been analyzed by using Bean critical state model. Using both temperature and field variations of ac susceptibility data, the material dependent parameters, such as critical current density as a function of temperature and effective volume fraction grains have been estimated. The Ag doped samples show relatively large critical current density compared to pure samples due to improved intergranular coupling. (author)

  13. Determining Confounding Sensitivities In Eddy Current Thin Film Measurements

    Energy Technology Data Exchange (ETDEWEB)

    Gros, Ethan; Udpa, Lalita; Smith, James A.; Wachs, Katelyn

    2016-07-01

    Determining Confounding Sensitivities In Eddy Current Thin Film Measurements Ethan Gros, Lalita Udpa, Electrical Engineering, Michigan State University, East Lansing MI 48824 James A. Smith, Experiment Analysis, Idaho National Laboratory, Idaho Falls ID 83415 Eddy current (EC) techniques are widely used in industry to measure the thickness of non-conductive films on a metal substrate. This is done using a system whereby a coil carrying a high-frequency alternating current is used to create an alternating magnetic field at the surface of the instrument's probe. When the probe is brought near a conductive surface, the alternating magnetic field will induce ECs in the conductor. The substrate characteristics and the distance of the probe from the substrate (the coating thickness) affect the magnitude of the ECs. The induced currents load the probe coil affecting the terminal impedance of the coil. The measured probe impedance is related to the lift off between coil and conductor as well as conductivity of the test sample. For a known conductivity sample, the probe impedance can be converted into an equivalent film thickness value. The EC measurement can be confounded by a number of measurement parameters. It is the goal of this research to determine which physical properties of the measurement set-up and sample can adversely affect the thickness measurement. The eddy current testing is performed using a commercially available, hand held eddy current probe (ETA3.3H spring loaded eddy probe running at 8 MHz) that comes with a stand to hold the probe. The stand holds the probe and adjusts the probe on the z-axis to help position the probe in the correct area as well as make precise measurements. The signal from the probe is sent to a hand held readout, where the results are recorded directly in terms of liftoff or film thickness. Understanding the effect of certain factors on the measurements of film thickness, will help to evaluate how accurate the ETA3.3H spring

  14. Eddy Current Flow Measurements in the FFTF

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Deborah L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Polzin, David L. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Omberg, Ronald P. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Makenas, Bruce J. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2017-02-02

    The Fast Flux Test Facility (FFTF) is the most recent liquid metal reactor (LMR) to be designed, constructed, and operated by the U.S. Department of Energy (DOE). The 400-MWt sodium-cooled, fast-neutron flux reactor plant was designed for irradiation testing of nuclear reactor fuels and materials for liquid metal fast breeder reactors. Following shut down of the Clinch River Breeder Reactor Plant (CRBRP) project in 1983, FFTF continued to play a key role in providing a test bed for demonstrating performance of advanced fuel designs and demonstrating operation, maintenance, and safety of advanced liquid metal reactors. The FFTF Program provides valuable information for potential follow-on reactor projects in the areas of plant system and component design, component fabrication, fuel design and performance, prototype testing, site construction, and reactor control and operations. This report provides HEDL-TC-1344, “ECFM Flow Measurements in the FFTF Using Phase-Sensitive Detectors”, March 1979.

  15. Measurement of MOS current mismatch in the weak inversion region

    International Nuclear Information System (INIS)

    Forti, F.; Wright, M.E.

    1994-01-01

    The MOS transistor matching properties in the weak inversion region have not received, in the past, the attention that the mismatch in the strong inversion region has. The importance of weak inversion biased transistors in low power CMOS analog systems calls for more extensive data on the mismatch in this region of operation. The study presented in this paper was motivated by the need of controlling the threshold matching in a low power, low noise amplifier discriminator circuit used in a silicon radiation detector read-out, where both the transistor dimensions and the currents had to be kept to a minimum. The authors have measured the current matching properties of MOS transistors operated in the weak inversion region. They measured a total of about 1,400 PMOS and NMOS transistors produced in four different processes and report here the results in terms of mismatch dependence on current density, device dimensions, and substrate voltage, without using any specific model for the transistor

  16. Compensation and trapping in CdZnTe radiation detectors studied by thermoelectric emission spectroscopy, thermally stimulated conductivity, and current-voltage measurements

    International Nuclear Information System (INIS)

    James, Ralph B.

    2000-01-01

    In today's commercially available counter-select-grade CdZnTe crystals for radiation detector applications, the thermal ionization energies of the traps and their types, whether electron or hole traps, were measured. The measurements were successfully done using thermoelectric emission spectroscopy (TEES) and thermally stimulated conductivity (TSC). For reliability, the electrical contacts to the sample were found to be very important and, instead of Au Schottky contacts, In Ohmic contacts had to be used. For the filling of the traps, photoexcitation was done at zero bias, at 20K and at wavelengths which gave the maximum bulk photoexcitation for the sample. Between the temperature range from 20 to 400 K, the TSC current was found to be on the order of ∼ 10,000 times or even larger than the TEES current, in agreement with theory, but only TEES could resolve the trap type and was sensitive to the deep traps. Large concentration of hole traps at 0.1 and 0.6 eV were observed and smaller contraction of electron traps at 0.4 eV was seen. These deep traps cause compensation in the material and also cause trapping that degrades the radiation detection measurement

  17. Optical sensors for the measurement of electric current and voltage

    Energy Technology Data Exchange (ETDEWEB)

    Rutgers, W R; Hulshof, H J.M.; Laurensse, I J; van der Wey, A H

    1987-01-01

    Optical sensors for the measurement of electrical current and voltage were developed for application in electric power systems. The current sensor, based on the Faraday effect in a monomode glass fiber, and the voltage sensor, based on the transverse Pockels effect in a crystal, are demonstrated in wide-band (10 MHz) interference-free measurements of pulsed currents and impulse voltages.

  18. BEAM-BASED MEASUREMENTS OF PERSISTENT CURRENT DECAY IN RHIC

    International Nuclear Information System (INIS)

    FISCHER, W.; JAIN, A.; TEPIKIAN, S.

    2001-01-01

    The two RHIC rings are equipped with superconducting dipole magnets. At injection, induced persistent currents in these magnets lead to a sextupole component. As the persistent currents decay with time, the horizontal and vertical chromaticities change. From magnet measurements of persistent current decays, chromaticity changes in the machine are estimated and compared with chromaticity measurements

  19. Time structure measurement of the ATLAS RPC gap current

    CERN Document Server

    Aielli, G; The ATLAS collaboration

    2010-01-01

    The current absorbed by an RPC represents the sum of the charge delivered in the gas by the ionizing events interesting the gap, integrated by the electrodes time constant. This is typically of the order of tens of ms thus dominating the gas discharge time scale and characterizing the granular structure observed in the current signal. In most cases this structure is considered as noise to be further integrated to observe the average gap current, used often as a detector monitoring parameter or to precisely measure the uncorrelated background rate effects. A remarkable case is given if a large number of particles is passing trough the detector within an integration time constant producing a current peak clearly detectable above the average noise. The ATLAS RPC system is equipped with a dedicated current monitoring based on an ADC capable of reading out the average value as well as the transient peaks of the currents above a given threshold. A study on such data was used to spot the gap HV noise, to monitor the...

  20. Method for measuring the resistive transition and critical current in superconductors using pulsed current

    International Nuclear Information System (INIS)

    McGinnis, W.C.; Jones, T.E.

    1993-01-01

    A method is described for measuring the intragranular critical current of a granular superconductive material, comprising the steps of: conducting a substantially rectangular electronic pulse through said material so as to conduct a current through said material such that when said intragranular critical current of said material is exceeded, any grains present in said material are in a superconducting state when said current is less than said intragranular critical current, said material having a critical temperature; measuring said current through said material while conducting said pulse; measuring a voltage difference across said material while conducting said pulse; and determining said intragranular critical current through said material by varying said current to discern a current level at which an electrical resistance of said material increases to that of a non-superconducting state as the grains of said material transition from said superconducting to said non-superconducting state

  1. Plasma position from ring current measurements in Extrap T1

    International Nuclear Information System (INIS)

    Brunsell, P.; Jin Li.

    1989-11-01

    The inductive coupling between the plasma and the four octupole field coils in the Extrap T1 device is utilized as a means of estimating the plasma position. The current in each octupole ring as well as the plasma current is measured by a Rogowski coil and the ring - plasma mutual inductance is then computed assuming axisymmetric plasma displacements. The obtained position is in agreement with internal magnetic probe measurements. The time - evolution of the plasma position for different external vertical and toroidal field strengths is studied. For the present discharge parameter a vertical field of about .008 T is found to give an almost radially stationary plasma. The results are compared with a simple equilibrium model

  2. Are CH2O measurements in the marine boundary layer suitable for testing the current understanding of CH4 photooxidation?: A model study

    Science.gov (United States)

    Wagner, V.; von Glasow, R.; Fischer, H.; Crutzen, P. J.

    2002-02-01

    On the basis of a data set collected during the Indian Ocean Experiment (INDOEX) campaign 1999, we investigated the formaldehyde (CH2O) budget in the southern Indian Ocean (SIO). With a photochemical box model we simulated the contribution of methane and nonmethane volatile organic compounds to the CH2O budget. To identify the reactions and model constraints that introduce the largest uncertainties in the modeled CH2O concentration, we carried out a local sensitivity analysis. Furthermore, a Monte Carlo method was used to assess the global error of the model predictions. According to this analysis the 2σ uncertainty in the modeled CH2O concentration is 49%. The deviation between observed (200 +/- 70 parts per trillion by volume (pptv) (2σ)) and modeled (224 +/- 110 pptv (2σ)) daily mean CH2O concentration is 12%. However, the combined errors of model and measurement are such that deviations as large as 65% are not significant at the 2σ level. Beyond the ``standard'' photochemistry we analyzed the impact of halogen and aerosol chemistry on the CH2O concentration and investigated the vertical distribution of CH2O in the marine boundary layer (MBL). Calculations with the Model of Chemistry Considering Aerosols indicate that, based on the current understanding, halogen chemistry and aerosol chemistry have no significant impact on the CH2O concentration under conditions encountered in the SIO. However, a detailed investigation including meteorological effects such as precipitation scavenging and convection reveals an uncertainty in state-of-the-art model predictions for CH2O in the MBL that is too large for a meaningful test of the current understanding of CH4 photooxidation.

  3. Basic properties of the current-current correlation measure for random Schroedinger operators

    International Nuclear Information System (INIS)

    Hislop, Peter D.; Lenoble, Olivier

    2006-01-01

    The current-current correlation measure plays a crucial role in the theory of conductivity for disordered systems. We prove a Pastur-Shubin-type formula for the current-current correlation measure expressing it as a thermodynamic limit for random Schroedinger operators on the lattice and the continuum. We prove that the limit is independent of the self-adjoint boundary conditions and independent of a large family of expanding regions. We relate this finite-volume definition to the definition obtained by using the infinite-volume operators and the trace-per-unit volume

  4. Measurement of toroidal plasma current in RF heated helical plasmas

    International Nuclear Information System (INIS)

    Besshou, Sakae

    1993-01-01

    This report describes the measurement of toroidal plasma current by a semiflexible Rogowski coil in a helical vacuum chamber. A Rogowski coil measures the toroidal plasma current with a resolution of 0.1 kA, frequency range of up to 1 kHz and sensitivity of 6.5 x 10 -9 V · s/A. We measured the spontaneous toroidal plasma current (from -1.2 to +1.2 kA) under electron cyclotron resonance heating at 0.94 T toroidal field in the Heliotron-E device. We found that the measured direction of toroidal plasma current changes its sign as in the predicted behavior of a neoclassical diffusion-driven bootstrap current, depending on the horizontal position of the plasma column. We explain the observed plasma currents in terms of the compound phenomenon of an ohmic current and a neoclassical diffusion-driven current. The magnitude of the neoclassical current component is smaller than the value predicted by a collisionless neoclassical theory. (author)

  5. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  6. Measurement of Neutrino Induced, Charged Current, Charged Pion Production

    Energy Technology Data Exchange (ETDEWEB)

    Wilking, Michael Joseph [Univ. of Colorado, Boulder, CO (United States)

    2009-05-01

    Neutrinos are among the least understood particles in the standard model of particle physics. At neutrino energies in the 1 GeV range, neutrino properties are typically determined by observing the outgoing charged lepton produced in a charged current quasi-elastic interactions. The largest charged current background to these measurements comes from charged current pion production interactions, for which there is very little available data.

  7. Hall probe for measuring high currents in superconducting coils

    International Nuclear Information System (INIS)

    Ferendeci, A.M.

    1986-01-01

    Constructional details of a compact Hall probe for measuring high currents in superconducting coils are given. The Hall probe is easy to assemble and can be inserted or removed from the system without breaking the superconducting loop. Upper current limit of the probe can be increased by using larger magnetic core material. Shielding becomes necessary if the probe holder is to be placed near large current dependent magnetic fields

  8. Converter for Measurement of non-sinusoidal current peak value

    DEFF Research Database (Denmark)

    Butvin, P.; Nielsen, Otto V; Brauer, Peter

    1997-01-01

    A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current.......A linear-response toroid with core wound of rapidly quenched soft magnetic metallic ribbon and fitted with two windings is used to enable correct measurement of mean peak value of non-sinusoidal and not noise-free alternating current....

  9. A Fiber-Optic Aircraft Lightning Current Measurement Sensor

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.

    2013-01-01

    A fiber-optic current sensor based on the Faraday Effect is developed for aircraft installations. It can measure total lightning current amplitudes and waveforms, including continuing current. Additional benefits include being small, lightweight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate in presence of magnetic field in the direction of light propagation. Measuring the total induced light polarization change yields the total current enclosed. The system operates at 1310nm laser wavelength and can measure approximately 300 A - 300 kA, a 60 dB range. A reflective polarimetric scheme is used, where the light polarization change is measured after a round-trip propagation through the fiber. A two-detector setup measures the two orthogonal polarizations for noise subtraction and improved dynamic range. The current response curve is non-linear and requires a simple spline-fit correction. Effects of high current were achieved in laboratory using combinations of multiple fiber and wire loops. Good result comparisons against reference sensors were achieved up to 300 kA. Accurate measurements on a simulated aircraft fuselage and an internal structure illustrate capabilities that maybe difficult with traditional sensors. Also tested at a commercial lightning test facility from 20 kA to 200 kA, accuracy within 3-10% was achieved even with non-optimum setups.

  10. Measurements of current penetration during PDX discharge start-up

    International Nuclear Information System (INIS)

    Meyerhofer, D.D.; Goldston, R.J.; Kaita, R.; Cavallo, A.; Grek, B.; Johnson, D.; McCune, D.C.; McGuire, K.; White, R.B.

    1984-11-01

    The current penetration phase of PDX discharges is examined. The Fast Ion Diagnostic Experiment has been used to measure the temporal evolution of the central q (r/a < 0.4), and to show the effect of magnetic perturbations on fast ions. During plasma current penetration, a series of magnetic perturbations was observed in the plasma. If the current was rising rapidly, the perturbations were accompanied by increases in β/sub theta/ + l/sub i//2 and decreases in the loop voltage, suggesting a rapid penetration of the plasma current. When the plasma current was rising slowly, a series of minor disruptions occurred. These were accompanied by decreases in β/sub theta/ + l/sub i//2 and the loop voltage, and increases in the plasma current. During this phase, current penetration may be enhanced by the change in the resistivity profile which accompanies the disruption

  11. TESTING CPT SYMMETRY WITH CURRENT AND FUTURE CMB MEASUREMENTS

    Energy Technology Data Exchange (ETDEWEB)

    Li, Si-Yu; Zhang, Xinmin [Theory Division, Institute of High Energy Physics, Chinese Academy of Science, P.O. Box 918-4, Beijing 100049 (China); Xia, Jun-Qing; Li, Hong [Key Laboratory of Particle Astrophysics, Institute of High Energy Physics, Chinese Academy of Science, P.O. Box 918-3, Beijing 100049 (China); Li, Mingzhe, E-mail: xiajq@ihep.ac.cn [Interdisciplinary Center for Theoretical Study, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2015-02-01

    In this paper, we use the current and future cosmic microwave background (CMB) experiments to test the Charge-Parity-Time Reversal (CPT) symmetry. We consider a CPT-violating interaction in the photon sector L{sub cs}∼p{sub μ}A{sub ν} F-tilde {sup μν}, which gives rise to a rotation of the polarization vectors of the propagating CMB photons. By combining the 9 yr WMAP, BOOMERanG 2003, and BICEP1 observations, we obtain the current constraint on the isotropic rotation angle α-bar =−2.12±1.14 (1σ), indicating that the significance of the CPT violation is about 2σ. Here, we particularly take the systematic errors of CMB measurements into account. Then, we study the effects of the anisotropies of the rotation angle [Δα( n-hat )] on the CMB polarization power spectra in detail. Due to the small effects, the current CMB polarization data cannot constrain the related parameters very well. We obtain the 95% C.L. upper limit of the variance of the anisotropies of the rotation angle C {sup α}(0) < 0.035 from all of the CMB data sets. More interestingly, including the anisotropies of rotation angle could lower the best-fit value of r and relax the tension on the constraints of r between BICEP2 and Planck. Finally, we investigate the capabilities of future Planck polarization measurements on α-bar and Δα( n-hat ). Benefited from the high precision of Planck data, the constraints of the rotation angle can be significantly improved.

  12. Fiber-Optic Sensor for Aircraft Lightning Current Measurement

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George G.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.

    2012-01-01

    An electric current sensor based on Faraday rotation effect in optical fiber was developed for measuring aircraft lightning current. Compared to traditional sensors, the design has many advantages including the ability to measure total current and to conform to structure geometries. The sensor is also small, light weight, non-conducting, safe from interference, and free of hysteresis and saturation. Potential applications include characterization of lightning current waveforms, parameters and paths, and providing environmental data for aircraft certifications. In an optical fiber as the sensing medium, light polarization rotates when exposed to a magnetic field in the direction of light propagation. By forming closed fiber loops around a conductor and applying Ampere s law, measuring the total light rotation yields the enclosed current. A reflective polarimetric scheme is used, where polarization change is measured after the polarized light travels round-trip through the sensing fiber. The sensor system was evaluated measuring rocket-triggered lightning over the 2011 summer. Early results compared very well against a reference current shunt resistor, demonstrating the sensor s accuracy and feasibility in a lightning environment. While later comparisons show gradually increasing amplitude deviations for an undetermined cause, the overall waveforms still compared very well.

  13. Online junction temperature measurement using peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    A new method for junction temperature measurement of MOS-gated power semiconductor switches is presented. The measurement method involves detecting the peak voltage over the external gate resistor of an IGBT or MOSFET during turn-on. This voltage is directly proportional to the peak gate current...

  14. Development of an external Faraday cup for beam current measurements

    International Nuclear Information System (INIS)

    Kim, Kye-Ryung; Jung, Myung-Hwan; Ra, Se-Jin; Lee, Seok-Ki

    2010-01-01

    In general, beam current measurements are very important for many kinds of experiments using highly energetic particle beams at accelerators, such as cyclotrons, linacs, etc. The Faraday cup is known to be one of the most popular beam current measurement tools. We developed an external Faraday cup to measure the beam current at a dedicated beam line for low-flux experiments installed at the MC-50 cyclotron of Korea Institute of Radiological and Medical Sciences (KIRAMS). It was designed for external beam current measurements and is composed of a vacuum chamber, an entrance window, a collimator, a electrostatic suppressor ring, and a cup. The window is made of 75-um-thick Kapton film, and the diameter of the collimator is 10 mm or 20 mm. The ring and the cup has 5-cm inner diameters, and the thickness of the bottom of the cup is 2 cm, which is enough to absorb the total proton energy up to 45 MeV. Using this external Faraday cup, we measured the beam current from the cyclotron, and we compared measured flux to the results from film dosimetry using GAF films.

  15. Resistance and sheet resistance measurements using electron beam induced current

    International Nuclear Information System (INIS)

    Czerwinski, A.; Pluska, M.; Ratajczak, J.; Szerling, A.; KaPtcki, J.

    2006-01-01

    A method for measurement of spatially uniform or nonuniform resistance in layers and strips, based on electron beam induced current (EBIC) technique, is described. High electron beam currents are used so that the overall resistance of the measurement circuit affects the EBIC signal. During the evaluation, the electron beam is scanned along the measured object, whose load resistance varies with the distance. The variation is compensated by an adjustable resistance within an external circuit. The method has been experimentally deployed for sheet resistance determination of buried regions of lateral confinements in semiconductor laser heterostructures manufactured by molecular beam epitaxy

  16. The current state of knowledge on operational sanitation measures to lower risk of Phytophthora ramorum spread and the need for further study

    Science.gov (United States)

    Yana Valachovic; Dave Rizzo; Brendan Twieg

    2013-01-01

    We are working to evaluate risks associated with human spread of the sudden oak death (SOD) pathogen, Phytophthora ramorum, to currently uninfested areas in California. Port-Orford-cedar (Chamaecyparis lawsoniana (A. Murray) Parl.) root disease (POC RD), caused by Phytophthora lateralis, has brought...

  17. Measurement in Marketing: Current Scenario, Recommendations and Challenges

    Directory of Open Access Journals (Sweden)

    Felipe Zambaldi

    2014-05-01

    Full Text Available The purpose of this article is to discuss about construct measurement in Marketing by summarizing the main considerations about the subject. First, it discusses the origins of the debates about the theme since the 1970s and describes its main consolidated models (the classical Churchill’s model, the COARSE model and the formative measurement model. Then it presents current concerns about the classical approach with relevant recommendations (particularly regarding multi-item measurement, single-item measurement, rating scales and cross-cultural aspects. At the end, it presents considerations about measurement trends in Marketing with emphasis on the Item Response Theory (IRT, Bayesian estimators and Partial Least Squares (PLS. The article updates the debate on the theme and contributes to Marketing experts and researchers who demand a current view about measurement and recommendations for research development. 

  18. A measurement of perpendicular current density in an aurora

    International Nuclear Information System (INIS)

    Bering, E.A.; Mozer, F.S.

    1975-01-01

    A Nike Tomahawk sounding rocket was launched into a 400-γ auroral substorm on February 7, 1972, from Esrange, Kiruna, Sweden. The rocket instrumentation included a split Langmuir probe plasma velocity detector and a double-probe electric field detector. Above 140-km altitude the electric field deduced from the ion flow velocity measurement and the electric field measured by the double probe agree to an accuracy within the uncertainties of the two measurements. The difference between the two measurements at altitudes below 140 km provides an in situ measurement of current density and conductivity. Alternatively, if values for the conductivity are assumed, the neutral wind velocity can be deduced. The height-integrated current was 0.11 A/m flowing at an azimuth of 276degree. The neutral winds were strong, exhibited substantial altitude variation in the east-west component, and were predominantly southward

  19. Current measurements by Faraday rotation in single mode optical fibers

    International Nuclear Information System (INIS)

    Chandler, G.I.; Jahoda, F.C.

    1984-01-01

    Development of techniques for measuring magnetic fields and currents by Faraday rotation in single-mode optical fibers has continued. We summarize the results of attempts to measure the toroidal plasma current in the ZT-40 Reversed-Field-Pinch using multi-turn fiber coils. The fiber response is reproducible and in accord with theory, but the amount and distribution of the stress-induced birefringence in this case are such that prediction of the sensor response at low currents is difficult if not impossible. The low-current difficulty can be overcome by twisting the fiber to induce a circular birefringence bias. We report the results of auxiliary experiments with a fiber that has been twisted with 15 turns per meter and then re-coated to lock the twist in place

  20. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  1. Lightning Current Measurement with Fiber-Optic Sensor

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.

    2014-01-01

    A fiber-optic current sensor is successfully developed with many potential applications for electric current measurement. Originally developed for in-flight lightning measurement, the sensor utilizes Faraday Effect in an optical fiber. The Faraday Effect causes linear light polarization in a fiber to rotate when the fiber is exposed to a magnetic field. The polarization change is detected using a reflective polarimetric scheme. Forming fiber loops and applying Ampere's law, measuring the total light rotation results in the determination of the total current enclosed. The sensor is conformable to complex structure geometry. It is also non-conductive and immune to electromagnetic interference, saturation or hysteresis. Installation is non-intrusive, and the sensor can be safely routed through flammable areas. Two similar sensor systems are described in this paper. The first system operates at 1310nm laser wavelength and is capable of measuring approximately 300 A - 300 kA, a 60 dB range. Laboratory validation results of aircraft lighting direct and in-direct effect current amplitudes are reported for this sensor. The second system operates at 1550nm wavelength and can measure about 400 A - 400 kA. Triggered-lightning measurement data are presented for this system. Good results are achieved in all cases.

  2. Proton current measurements using the prompt gamma ray diagnostic technique

    International Nuclear Information System (INIS)

    Leeper, R.J.; Burns, E.J.T.; Johnson, D.J.; McMurtry, W.M.

    1981-01-01

    Prompt gamma ray signals from the nuclear reaction 7 Li(p,γ) 8 Be have been used to make time resolved proton current measurements. In these measurements, the proton beam was allowed to strike cylindrical thick lithium metal targets. The time integrated proton current was measured using gamma activation of copper via the reaction 63 Cu(γ,n) 62 Cu(β+). The positron activity of the copper sample was easily measured using coincidence counting techniques. The number of 62 Cu atoms produced per proton incident on a thick Li metal target was determined with separate calibration runs performed on the Sandia 2.5 MeV Van de Graaff accelerator. The time history of the prompt gamma production was measured using six EGG NPM-54 scintillator photomultiplier combinations shielded by 96.5 cm of concrete and 5.1 cm of Pb. The use of six scintillator photomultiplier combinations was necessary to increase the statistical precision of the data. The normalization of the prompt gamma time history data with the total time integrated proton-current measurement yielded the absolute time resolved proton current on target. Data from runs performed on the Sandia Proto I accelerator will be presented

  3. Measurement of fast risetime megampere currents by quartz gauge

    International Nuclear Information System (INIS)

    Williams, R.R.; McDaniel, D.H.; Stinnett, R.W.

    1980-01-01

    Quartz gauges have been used on the Sandia National Laboratories Proto II accelerator to measure current in the magnetically insulated transmission line at the 11 TW power level. The accelerator delivers 3.5 MA at 2 x 10 14 A/s in a 40 ns pulse to a 0.0127 m diameter aluminum liner to produce a high density plasma. At this radius and dI/dt levels, the B-dot monitors no longer function for the measurement of load current because the monitor suffers electrical breakdown. Quartz pressure gauges mounted at a radius of 0.0086 m have successfully measured the magnetic pressure due to the load current with nanosecond temporal resolution

  4. Simulation of vibration-induced effect on plasma current measurement using a fiber optic current sensor.

    Science.gov (United States)

    Descamps, Frédéric; Aerssens, Matthieu; Gusarov, Andrei; Mégret, Patrice; Massaut, Vincent; Wuilpart, Marc

    2014-06-16

    An accurate measurement of the plasma current is of paramount importance for controlling the plasma magnetic equilibrium in tokamaks. Fiber optic current sensor (FOCS) technology is expected to be implemented to perform this task in ITER. However, during ITER operation, the vessel and the sensing fiber will be subject to vibrations and thus to time-dependent parasitic birefringence, which may significantly compromise the FOCS performance. In this paper we investigate the effects of vibrations on the plasma current measurement accuracy under ITER-relevant conditions. The simulation results show that in the case of a FOCS reflection scheme including a spun fiber and a Faraday mirror, the error induced by the vibrations is acceptable regarding the ITER current diagnostics requirements.

  5. Current Consumption Measurements with a Carrier Aggregation Smartphone

    DEFF Research Database (Denmark)

    Sanchez-Mejias, Rafael; Guo, Yu; Lauridsen, Mads

    2014-01-01

    on this topic. Currently there are only theoretical expansions of LTE release 8 power models available, but this article presents the first publicly available current consumption measurements on a commercial CA-capable UE. In this work it is examined how the activation and use of CA (10 + 10 MHz) affects the UE......Carrier Aggregation (CA) is introduced in LTE release 10 to improve data rates by allowing the User Equipment (UE) to receive data on more than one LTE carrier. The related increased complexity is expected to affect the UE current consumption, but yet no empirical evaluation has been published...

  6. Measuring electric conductivity in liquid metals by eddy current method

    International Nuclear Information System (INIS)

    Zhuravlev, S.P.; Ostrovskij, O.I.; Grigoryan, V.A.

    1982-01-01

    Technique permitting to apply the method of vertiginous currents for investigation of electric conductivity of metal melts in the high temperature range is presented. Interferences affecting accuracy of measurements are specified and ways of their removing are pointed out. Scheme of measuring and design of the facility are described. Results of measuring electric resistance of liquid Fe, Co, Ni obtained for the first time by this method are presented. The data obtained agree with the results of measurements conducted by the method of the rotating magnetic field. Difference in absolute values of electric resistance in parallel experiments for each metal does not exceed 4%

  7. Cryogenic Current Comparator for Absolute Measurement of the Dark Current of the Superconducting Cavities for Tesla

    CERN Document Server

    Knaack, K; Wittenburg, K

    2003-01-01

    A newly high performance SQUID based measurement system for detecting dark currents, generated by superconducting cavities for TESLA is proposed. It makes use of the Cryogenic Current Comparator principle and senses dark currents in the nA range with a small signal bandwidth of 70 kHz. To reach the maximum possible energy in the TESLA project is a strong motivation to push the gradients of the superconducting cavities closer to the physical limit of 50 MV/m. The field emission of electrons (the so called dark current) of the superconducting cavities at strong fields may limit the maximum gradient. The absolute measurement of the dark current in correlation with the gradient will give a proper value to compare and classify the cavities. This contribution describes a Cryogenic Current Comparator (CCC) as an excellent and useful tool for this purpose. The most important component of the CCC is a high performance DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the extracted ...

  8. History and current safety measures at Laguna Palcacocha, Huaraz, Peru

    Science.gov (United States)

    Salazar Checa, César; Cochachin, Alejo; Frey, Holger; Huggel, Christian; Portocarrero, César

    2017-04-01

    Laguna Palcacocha is a large glacier lake in the Cordillera Blanca, Peru, located in the Quillcay catchment, above the city of Huaraz, the local capital. On 13 December 1941, the moraine dam lake collapsed, probably after having been impacted by a large ice avalanche, and triggered a major outburst flood. This GLOF destroyed about a third of the city of Huaraz, causing about 2,000 casualties and is therefore one of the deadliest glacier lake outbursts known in history. In 1974, the Glaciology Unit of Peru, responsible for the studying, monitoring and mitigation works related to glacier hazards installed a reinforcement of the natural moraine dam of the newly filled Laguna Palcacocha, with an artificial drainage channel at 7 m below the crest of the reinforced dam. At that time, the lake had an area of 66,800 m2 and a volume of 0.5 x 106 m3. During the past decades, in the course of continued glacier retreat, Laguna Palcacocha has undergone an extreme growth. In February 2016, the lake had an area of 514,000 m2 (7.7 times the area of 1974) and a volume of more than 17 x 106 m3 (more than 34 times the volume of 1974). At the same time, the city of Huaraz, located 20 km downstream of the lake, grew significantly after its almost complete destruction by the 1970 earthquake. Today, about 120,000 people are living in the city. Due to the persisting possibility for large ice avalanches directly above the Palcacocha lake, this constitutes a high-risk situation, requiring new hazard and risk mitigation measures. As an immediate temporal measure, in order to bridge the time until the realization of a more permanent measure, a syphoning system has been installed in 2011, using about ten 700-m pipes with a 10-inch (25.4 cm) diameter. The aim of this syphoning attempt is to lower the lake level by about 7 m, and therefore reduce the lake volume on the one hand, and also reach a higher dam freeboard. However, the system is less effective than assumed, currently the lake level

  9. A fiber-optic current sensor for lightning measurement applications

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.

    2015-05-01

    An optical-fiber sensor based on Faraday Effect is developed for measuring total lightning electric current. It has many unique capabilities not possible with traditional current sensors. Designed for aircraft installation, the sensor is lightweight, non-conducting, structure-conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can also be used on windmills, lightning towers, and can help validate lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. The broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with about 60 dB dynamic range. Three sensor systems were built with different sensitivities from different laser wavelengths. Operating at 850nm, the first system uses twisted single-mode fiber and has a 150 A - 150 KA range. The second system operates at 1550nm, uses spun polarization maintaining fiber, and can measure 400 A - 400 KA. Both systems were validated with rocket-triggered lightning measurements and achieved excellent results when compared to a resistive shunt. The third system operates at 1310nm, uses spun polarization maintaining fiber, and can measure approximately 300 A - 300 KA. High current measurements up to 200 KA were demonstrated at a commercial lightning test facility. The system was recently installed on an aircraft and flown near icing weather conditions.

  10. A Fiber-Optic Current Sensor for Lightning Measurement Applications

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.

    2015-01-01

    An optical-fiber sensor based on Faraday Effect is developed for measuring total lightning electric current. It has many unique capabilities not possible with traditional current sensors. Designed for aircraft installation, the sensor is lightweight, non-conducting, structure-conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can also be used on windmills, lightning towers, and can help validate lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. The broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with about 60 dB dynamic range. Three sensor systems were built with different sensitivities from different laser wavelengths. Operating at 850nm, the first system uses twisted single-mode fiber and has a 150 A - 150 KA range. The second system operates at 1550nm, uses spun polarization maintaining fiber, and can measure 400 A - 400 KA. Both systems were validated with rocket-triggered lightning measurements and achieved excellent results when compared to a resistive shunt. The third system operates at 1310nm, uses spun polarization maintaining fiber, and can measure approximately 300 A - 300 KA. High current measurements up to 200 KA were demonstrated at a commercial lightning test facility. The system was recently installed on an aircraft and flown near icing weather conditions.

  11. Current trends in outcome studies for children with hearing loss and the need to establish a comprehensive framework of measuring outcomes in children with hearing loss in China

    Directory of Open Access Journals (Sweden)

    Xueman Liu

    2016-06-01

    Full Text Available Since the 1970s, outcome studies for children with hearing loss expanded from focusing on assessing auditory awareness and speech perception skills to evaluating language and speech development. Since the early 2000s, the multi-center large scale research systematically studied outcomes in the areas of auditory awareness, speech-perception, language development, speech development, educational achievements, cognitive development, and psychosocial development. These studies advocated the establishment of baseline and regular follow-up evaluations with a comprehensive framework centered on language development. Recent research interests also include understanding the vast differences in outcomes for children with hearing loss, understanding the relationships between neurocognitive development and language acquisition in children with hearing loss, and using outcome studies to guide evidence-based clinical practice. After the establishment of standardized Mandarin language assessments, outcomes research in Mainland China has the potential to expand beyond auditory awareness and speech perception studies.

  12. Surface Current Measurements In Terra Nova Bay By Hf Radar

    Science.gov (United States)

    Flocco, D.; Falco, P.; Wadhams, P.; Spezie, G.

    We present the preliminary results of a field experiment carried out within frame- work of the CLIMA project of the Italian National Programme for Antarctic Research (PNRA) and in cooperation with the Scott Polar Research Institute of Cambridge. Dur- ing the second period (02/12/1999-23/01/2000) of the XV Italian expedition a coastal radar was used to characterize the current field in the area of Terra Nova Bay (TNB). One of the aims of the CLIMA (Climatic Long-term Interactions for the Mass balance in Antarctica) project is to determine the role of the polynya in the sea ice mass bal- ance, water structure and local climate. The OSCR-II experiment was planned in order to provide surface current measurements in the area of TNB polynya, one of the most important coastal polynya of the Ross Sea. OSCR (Ocean Surface Current Radar) is a shore based, remote sensing system designed to measure sea surface currents in coastal waters. Two radar sites (a master and a slave) provide with radial current mea- surements; data combined from both sites yield the total current vector. Unfortunately the master and slave stations did not work together throughout the whole period of the experiment. A description of the experiment and a discussion of the results, will be proposed.

  13. Fiber-Optic Current Sensor Validation with Triggered Lightning Measurements

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel G.; Snyder, Gary P.

    2013-01-01

    A fiber optic current sensor based on the Faraday Effect is developed that is highly suitable for aircraft installation and can measure total current enclosed in a fiber loop down to DC. Other attributes include being small, light-weight, non-conducting, safe from electromagnetic interference, and free of hysteresis and saturation. The Faraday Effect causes light polarization to rotate when exposed to a magnetic field in the direction of light propagation. Measuring the induced light polarization rotation in fiber loops yields the total current enclosed. Two sensor systems were constructed and installed at Camp Blanding, Florida, measuring rocket-triggered lightning. The systems were similar in design but with different laser wavelengths, sensitivities and ranges. Results are compared to a shunt resistor as reference. The 850nm wavelength system tested in summer 2011 showed good result comparison early. However, later results showed gradual amplitude increase with time, attributed to corroded connections affecting the 50-ohm output termination. The 1550nm system also yielded good results in the summer 2012. The successful measurements demonstrate the fiber optic sensor's accuracies in capturing real lightning currents, and represent an important step toward future aircraft installation.

  14. SQUID Based Cryogenic Current Comparator for Measurements of the Dark Current of Superconducting Cavities

    CERN Document Server

    Vodel, W; Neubert, R; Nietzsche, S

    2005-01-01

    This contribution presents a LTS-SQUID based Cryogenic Current Comparator (CCC) for detecting dark currents, generated e.g. by superconducting cavities for the upcoming X-FEL project at DESY. To achieve the maximum possible energy the gradients of the superconducting RF cavities should be pushed close to the physical limit of 50 MV/m. The measurement of the undesired field emission of electrons (the so-called dark current) in correlation with the gradient will give a proper value to compare and classify the cavities. The main component of the CCC is a high performance LTS-DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the extracted dark current. For this reason the input coil of the SQUID is connected across a special designed toroidal niobium pick-up coil (inner diameter: about 100 mm) for the passing electron beam. A noise limited current resolution of nearly 2 pA/√(Hz) with a measurement bandwidth of up to 70 kHz was achieved without the pick-up coil. Now, ...

  15. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    Science.gov (United States)

    Sutanto, E.; Chandra, F.; Dinata, R.

    2017-05-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA.

  16. An accurate low current measurement circuit for heavy iron beam current monitor

    International Nuclear Information System (INIS)

    Zhou Chaoyang; Su Hong; Mao Ruishi; Dong Chengfu; Qian Yi; Kong Jie

    2012-01-01

    Heavy-ion beams at 10 6 particles per second have been applied to the treatment of deep-seated inoperable tumors in the therapy terminal of the Heavy Ion Research Facility in Lanzhou (HIRFL) which is located at the Institute of Modern Physics, Chinese Academy of Sciences (IMP, CAS). An accurate low current measurement circuit following a Faraday cup was developed to monitor the beam current at pA range. The circuit consisted of a picoammeter with a bandwidth of 1 kHz and a gated integrator (GI). A low input bias current precision amplifier and new guarding and shielding techniques were used in the picoammeter circuit which allowed as to measure current less than 1 pA with a current gain of 0.22 V/pA and noise less than 10 fA. This paper will also describe a novel compensation approach which reduced the charge injection from switches in the GI to 10 −18 C, and a T-switch configuration which was used to eliminate leakage current in the reset switch.

  17. Simulation of leakage current measurement on medical devices using helmholtz coil configuration with different current flow

    International Nuclear Information System (INIS)

    Sutanto, E; Chandra, F; Dinata, R

    2017-01-01

    Leakage current measurement which can follow IEC standard for medical device is one of many challenges to be answered. The IEC 60601-1 has defined that the limit for a leakage current for Medical Device can be as low as 10 µA and as high as 500 µA, depending on which type of contact (applied part) connected to the patient. Most people are using ELCB (Earth-leakage circuit breaker) for safety purpose as this is the most common and available safety device in market. One type of ELCB devices is RCD (Residual Current Device) and this RCD type can measure the leakage current directly. This work will show the possibility on how Helmholtz Coil Configuration can be made to be like the RCD. The possibility is explored by comparing the magnetic field formula from each device, then it proceeds with a simulation using software EJS (Easy Java Simulation). The simulation will make sure the concept of magnetic field current cancellation follows the RCD concept. Finally, the possibility of increasing the measurement’s sensitivity is also analyzed. The sensitivity is needed to see the possibility on reaching the minimum leakage current limit defined by IEC, 0.01mA. (paper)

  18. Arrester Resistive Current Measuring System Based on Heterogeneous Network

    Science.gov (United States)

    Zhang, Yun Hua; Li, Zai Lin; Yuan, Feng; Hou Pan, Feng; Guo, Zhan Nan; Han, Yue

    2018-03-01

    Metal Oxide Arrester (MOA) suffers from aging and poor insulation due to long-term impulse voltage and environmental impact, and the value and variation tendency of resistive current can reflect the health conditions of MOA. The common wired MOA detection need to use long cables, which is complicated to operate, and that wireless measurement methods are facing the problems of poor data synchronization and instability. Therefore a novel synchronous measurement system of arrester current resistive based on heterogeneous network is proposed, which simplifies the calculation process and improves synchronization, accuracy and stability and of the measuring system. This system combines LoRa wireless network, high speed wireless personal area network and the process layer communication, and realizes the detection of arrester working condition. Field test data shows that the system has the characteristics of high accuracy, strong anti-interference ability and good synchronization, which plays an important role in ensuring the stable operation of the power grid.

  19. Four-point probe measurements using current probes with voltage feedback to measure electric potentials

    Science.gov (United States)

    Lüpke, Felix; Cuma, David; Korte, Stefan; Cherepanov, Vasily; Voigtländer, Bert

    2018-02-01

    We present a four-point probe resistance measurement technique which uses four equivalent current measuring units, resulting in minimal hardware requirements and corresponding sources of noise. Local sample potentials are measured by a software feedback loop which adjusts the corresponding tip voltage such that no current flows to the sample. The resulting tip voltage is then equivalent to the sample potential at the tip position. We implement this measurement method into a multi-tip scanning tunneling microscope setup such that potentials can also be measured in tunneling contact, allowing in principle truly non-invasive four-probe measurements. The resulting measurement capabilities are demonstrated for \

  20. Resistivity measurements using a direct current induction method (1963)

    International Nuclear Information System (INIS)

    Delaplace, J.; Hillairet, J.

    1964-01-01

    The conventional methods for measuring electrical resistivities necessitate the fixing of electrical contacts on the sample either mechanically or by soldering. Furthermore it is also necessary to carry,out the measurements on low cross-section samples which are not always easy to obtain. Our direct-current induction method on the other hand requires no contacts and can easily be applied to samples of large cross-section. The sample is placed in a uniform magnetic field; at the moment when the current is cut, eddy currents appear in the sample which tend to oppose the disappearance of the field. The way in which the magnetic flux decreases in the sample makes it possible to determine the resistivity of the material. This method has been applied to samples having diameters of between 1 and 30 mm in the case of metals which are good conductors. It gives a value for the local resistivity and makes it possible to detect any variation along a sample. The measurements can be carried out at all temperature from a few degrees absolute to 500 deg. C. We have used the induction method to follow the purification of beryllium by zone-melting; it is in effect possible to estimate the purity of a material by resistivity measurements. We have measured the resistivity along each bar treated by the zone-melting technique and have thus, localised the purest section. High temperature measurements have been carried out on uranium carbide and on iron-aluminium alloys. This method constitutes an interesting means of investigation the resistivity of solid materials. Its accuracy and rapidity make it particularly adapted both to fundamental research and to production control. (authors) [fr

  1. Music-Evoked Emotions—Current Studies

    Science.gov (United States)

    Schaefer, Hans-Eckhardt

    2017-01-01

    The present study is focused on a review of the current state of investigating music-evoked emotions experimentally, theoretically and with respect to their therapeutic potentials. After a concise historical overview and a schematic of the hearing mechanisms, experimental studies on music listeners and on music performers are discussed, starting with the presentation of characteristic musical stimuli and the basic features of tomographic imaging of emotional activation in the brain, such as functional magnetic resonance imaging (fMRI) and positron emission tomography (PET), which offer high spatial resolution in the millimeter range. The progress in correlating activation imaging in the brain to the psychological understanding of music-evoked emotion is demonstrated and some prospects for future research are outlined. Research in psychoneuroendocrinology and molecular markers is reviewed in the context of music-evoked emotions and the results indicate that the research in this area should be intensified. An assessment of studies involving measuring techniques with high temporal resolution down to the 10 ms range, as, e.g., electroencephalography (EEG), event-related brain potentials (ERP), magnetoencephalography (MEG), skin conductance response (SCR), finger temperature, and goose bump development (piloerection) can yield information on the dynamics and kinetics of emotion. Genetic investigations reviewed suggest the heredity transmission of a predilection for music. Theoretical approaches to musical emotion are directed to a unified model for experimental neurological evidence and aesthetic judgment. Finally, the reports on musical therapy are briefly outlined. The study concludes with an outlook on emerging technologies and future research fields. PMID:29225563

  2. Quantifying short-lived events in multistate ionic current measurements.

    Science.gov (United States)

    Balijepalli, Arvind; Ettedgui, Jessica; Cornio, Andrew T; Robertson, Joseph W F; Cheung, Kin P; Kasianowicz, John J; Vaz, Canute

    2014-02-25

    We developed a generalized technique to characterize polymer-nanopore interactions via single channel ionic current measurements. Physical interactions between analytes, such as DNA, proteins, or synthetic polymers, and a nanopore cause multiple discrete states in the current. We modeled the transitions of the current to individual states with an equivalent electrical circuit, which allowed us to describe the system response. This enabled the estimation of short-lived states that are presently not characterized by existing analysis techniques. Our approach considerably improves the range and resolution of single-molecule characterization with nanopores. For example, we characterized the residence times of synthetic polymers that are three times shorter than those estimated with existing algorithms. Because the molecule's residence time follows an exponential distribution, we recover nearly 20-fold more events per unit time that can be used for analysis. Furthermore, the measurement range was extended from 11 monomers to as few as 8. Finally, we applied this technique to recover a known sequence of single-stranded DNA from previously published ion channel recordings, identifying discrete current states with subpicoampere resolution.

  3. AN INDUCTION SENSOR FOR MEASURING CURRENTS OF NANOSECOND RANGE

    Directory of Open Access Journals (Sweden)

    S. P. Shalamov

    2016-11-01

    Full Text Available Purpose. A current meter based on the principle of electromagnetic induction is designed to register the current flowing in the rod lightning. The aim of the article is to describe the way of increasing the sensitivity of the converter by means of their serial communication. Methodology. The recorded current is in the nanosecond range. If compared with other methods, meters based on the principle of electromagnetic induction have several advantages, such as simplicity of construction, reliability, low cost, no need in a power source, relatively high sensitivity. Creation of such a meter is necessary, because in some cases there is no possibility to use a shunt. Transient properties of a meter are determined by the number of turns and the constant of integration. Sensitivity is determined by measuring the number of turns, the coil sectional area, the core material and the integration constant. For measuring the magnetic field pulses with a rise time of 5 ns to 50 ns a meter has turns from 5 to 15. The sensitivity of such a meter is low. When the number of turns is increased, the output signal and the front increase. Earlier described dependencies were used to select the main parameters of the converter. It was based on generally accepted and widely known equivalent circuit. The experience of created earlier pulse magnetic field meters was considered both for measuring the magnetic fields, and large pulse current. Originality. Series connection of converters has the property of a long line. The level of the transient response of the meter is calculated. The influence of parasitic parameters on the type of meter transient response is examined. The shown construction was not previously described. Practical value. The results of meter implementation are given. The design peculiarities of the given measuring instruments are shown.

  4. Leakage current measurements on pixelated CdZnTe detectors

    International Nuclear Information System (INIS)

    Dirks, B.P.F.; Blondel, C.; Daly, F.; Gevin, O.; Limousin, O.; Lugiez, F.

    2006-01-01

    In the field of the R and D of a new generation hard X-ray cameras for space applications we focus on the use of pixelated CdTe or CdZnTe semiconductor detectors. They are covered with 64 (0.9x0.9 mm 2 ) or 256 (0.5x0.5 mm 2 ) pixels, surrounded by a guard ring and operate in the energy ranging from several keV to 1 MeV, at temperatures between -20 and +20 o C. A critical parameter in the characterisation of these detectors is the leakage current per pixel under polarisation (∼50-500 V/mm). In operation mode each pixel will be read-out by an integrated spectroscopy channel of the multi-channel IDeF-X ASIC currently developed in our lab. The design and functionality of the ASIC depends directly on the direction and value of the current. A dedicated and highly insulating electronics circuit is designed to automatically measure the current in each individual pixel, which is in the order of tens of pico-amperes. Leakage current maps of different CdZnTe detectors of 2 and 6 mm thick and at various temperatures are presented and discussed. Defect density diagnostics have been performed by calculation of the activation energy of the material

  5. Measurement of neoclassically predicted edge current density at ASDEX Upgrade

    Science.gov (United States)

    Dunne, M. G.; McCarthy, P. J.; Wolfrum, E.; Fischer, R.; Giannone, L.; Burckhart, A.; the ASDEX Upgrade Team

    2012-12-01

    Experimental confirmation of neoclassically predicted edge current density in an ELMy H-mode plasma is presented. Current density analysis using the CLISTE equilibrium code is outlined and the rationale for accuracy of the reconstructions is explained. Sample profiles and time traces from analysis of data at ASDEX Upgrade are presented. A high time resolution is possible due to the use of an ELM-synchronization technique. Additionally, the flux-surface-averaged current density is calculated using a neoclassical approach. Results from these two separate methods are then compared and are found to validate the theoretical formula. Finally, several discharges are compared as part of a fuelling study, showing that the size and width of the edge current density peak at the low-field side can be explained by the electron density and temperature drives and their respective collisionality modifications.

  6. Measurement of neoclassically predicted edge current density at ASDEX Upgrade

    International Nuclear Information System (INIS)

    Dunne, M.G.; McCarthy, P.J.; Wolfrum, E.; Fischer, R.; Giannone, L.; Burckhart, A.

    2012-01-01

    Experimental confirmation of neoclassically predicted edge current density in an ELMy H-mode plasma is presented. Current density analysis using the CLISTE equilibrium code is outlined and the rationale for accuracy of the reconstructions is explained. Sample profiles and time traces from analysis of data at ASDEX Upgrade are presented. A high time resolution is possible due to the use of an ELM-synchronization technique. Additionally, the flux-surface-averaged current density is calculated using a neoclassical approach. Results from these two separate methods are then compared and are found to validate the theoretical formula. Finally, several discharges are compared as part of a fuelling study, showing that the size and width of the edge current density peak at the low-field side can be explained by the electron density and temperature drives and their respective collisionality modifications. (paper)

  7. Current measurement system utilizing cryogenic techniques for the absolute measurement of the magnetic flux quantum

    International Nuclear Information System (INIS)

    Endo, T.; Murayama, Y.; Sakamoto, Y.; Sakuraba, T.; Shiota, F.

    1989-01-01

    A series of systems composed of cryogenic devices such as a Josephson potentiometer and a cryogenic current comparator has been proposed and developed to precisely measure a current with any value up to 1 A. These systems will be used to measure the injected electrical energy with an uncertainty of the order of 0.01 ppm or less in the absolute measurement of the magnetic flux quantum by superconducting magnetic levitation. Some preliminary experiments are described

  8. Direct-current proton-beam measurements at Los Alamos

    International Nuclear Information System (INIS)

    Sherman, J.; Stevens, R.R.; Schneider, J.D.; Zaugg, T.

    1994-01-01

    Recently, a CW proton accelerator complex was moved from Chalk River Laboratories (CRL) to Los Alamos National Laboratory. This includes a 50-keV dc proton injector with a single-solenoid low-energy beam transport system (LEBT) and a CW 1.25-MeV, 267-MHz radiofrequency quadrupole (RFQ). The move was completed after CRL had achieved 55-mA CW operation at 1.25 MeV using 250-kW klystrode tubes to power the RFQ. These accelerator components are prototypes for the front end of a CW linac required for an accelerator-driven transmutation linac, and they provide early confirmation of some CW accelerator components. The injector (ion source and LEBT) and emittance measuring unit are installed and operational at Los Alamos. The dc microwave ion source has been operated routinely at 50-keV, 75-mA hydrogen-ion current. This ion source has demonstrated very good discharge and H 2 gas efficiencies, and sufficient reliability to complete CW RFQ measurements at CRL. Proton fraction of 75% has been measured with 550-W discharge power. This high proton fraction removes the need for an analyzing magnet. Proton LEBT emittance measurements completed at Los Alamos suggest that improved transmission through the RFQ may be achieved by increasing the solenoid focusing current. Status of the final CW RFQ operation at CRL and the installation of the RFQ at Los Alamos is given

  9. Measurements of the reverse current of highly irradiated silicon sensors to determine the effective energy and current related damage rate

    Science.gov (United States)

    Wiehe, Moritz; Wonsak, S.; Kuehn, S.; Parzefall, U.; Casse, G.

    2018-01-01

    The reverse current of irradiated silicon sensors leads to self heating of the sensor and degrades the signal to noise ratio of a detector. Precise knowledge of the expected reverse current during detector operation is crucial for planning and running experiments in High Energy Physics. The dependence of the reverse current on sensor temperature and irradiation fluence is parametrized by the effective energy and the current related damage rate, respectively. In this study 18 n-in-p mini silicon strip sensors from companies Hamamatsu Photonics and Micron Semiconductor Ltd. were deployed. Measurements of the reverse current for different bias voltages were performed at temperatures of -32 ° C, -27 ° C and -23 ° C. The sensors were irradiated with reactor neutrons in Ljubljana to fluences ranging from 2 × 1014neq /cm2 to 2 × 1016neq /cm2. The measurements were performed directly after irradiation and after 10 and 30 days of room temperature annealing. The aim of the study presented in this paper is to investigate the reverse current of silicon sensors for high fluences of up to 2 × 1016neq /cm2 and compare the measurements to the parametrization models.

  10. First current density measurements in the ring current region using simultaneous multi-spacecraft CLUSTER-FGM data

    Directory of Open Access Journals (Sweden)

    C. Vallat

    2005-07-01

    Full Text Available The inner magnetosphere's current mapping is one of the key elements for current loop closure inside the entire magnetosphere. A method for directly computing the current is the multi-spacecraft curlometer technique, which is based on the application of Maxwell-Ampère's law. This requires the use of four-point magnetic field high resolution measurements. The FGM experiment on board the four Cluster spacecraft allows, for the first time, an instantaneous calculation of the magnetic field gradients and thus a measurement of the local current density. This technique requires, however, a careful study concerning all the factors that can affect the accuracy of the J estimate, such as the tetrahedral geometry of the four spacecraft, or the size and orientation of the current structure sampled. The first part of this paper is thus providing a detailed analysis of the method accuracy, and points out the limitations of this technique in the region of interest. The second part is an analysis of the ring current region, which reveals, for the first time, the large latitudinal extent of the ring current, for all magnetic activity levels, as well as the latitudinal evolution of the perpendicular (and parallel components of the current along the diffuse auroral zone. Our analysis also points out the sharp transition between two distinct plasma regions, with the existence of high diamagnetic currents at the interface, as well as the filamentation of the current inside the inner plasma sheet. A statistical study over multiple perigee passes of Cluster (at about 4 RE from the Earth reveals the azimuthal extent of the partial ring current. It also reveals that, at these distances and all along the evening sector, there isn't necessarily a strong dependence of the local current density value on the magnetic activity level. This is a direct consequence of the ring current morphology evolution, as well as the relative

  11. Poloidal polarimeter for current density measurements in ITER

    International Nuclear Information System (INIS)

    Donne, A.J.H.; Graswinckel, M.F.; Cavinato, M.; Giudicotti, L.; Zilli, E.; Gil, C.; Koslowski, H.R.; McCarthy, P.; Nyhan, C.; Prunty, S.; Spillane, M.; Walker, C.

    2004-01-01

    One of the systems envisaged for measuring the current density profile in the ITER is a 118 μm poloidal polarimeter system. The proposed system has two independent views: one fan of chords observes the plasma via an equatorial port and a second fan views down from an upper port. This article will present the status of the on-going work and will address issues as sensitivity and accuracy, refraction, Gaussian beam ray-tracing, alignment, and calibration as well as some specific design details

  12. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  13. The ENIQ pilot study: current status

    Energy Technology Data Exchange (ETDEWEB)

    Lemaitre, P; Eriksen, B; Crutzen, S [European Commission, DG Joint Research Centre, Petten (Netherlands); Hansch, M [Preussische Elektrizitaets-AG (Preussenelektra), Hannover (Germany); Whittle, J [AEA Technology, Warrington (United Kingdom)

    1998-11-01

    A pilot study is currently being carried out by ENIQ (European Network for Inspection Qualification) in order to explore the issues involved in inspection qualification applied along the general principles of the European methodology. The components selected for the pilot study are austenitic pipe to pipe and pipe to elbows welds typical of those in BWR recirculation loops. A range of defect parameters has been defined. A suitable inspection procedure designed to find the designated defects will be applied to geometrically representative test pieces. The procedure/equipment will be qualified through open trials and technical justification. The personnel qualification will be done in a blind way. Once all features of the inspection system will have been qualified an in-service inspection will be simulated in order to test the feasibility of the qualification approach followed. In this paper the current status of this pilot study is discussed. (orig.)

  14. Experimental studies of coaxial plasma gun current

    International Nuclear Information System (INIS)

    Price, D.W.

    1988-01-01

    In this investigation of a coaxial plasma gun, plasma sheath currents and related behavior are examined. Plasma behavior in the gun affects gun characteristics. Plasma gun applications are determined by the plasma behavior. The AFWL PUFF capacitor bank (72 μF, 29 nH, 120 kV) drives the plasma gun using a deuterium fill gas. The gas breakdown site is isolated from the dielectric/vacuum interface in the AFWL system. Two gas values deliver gas in the system. The first delivers gas from the gun breech and the second optional valve delivers gas to the gun muzzle. Currents and voltages are measured by Rogowski coils, B probes and capacitive voltage probes. A O-D slug model is used to predict the current, inductance, gun voltage and plasma sheath velocity. The slug model assumes the sheath transits the gun with all mass in the sheath. In the snowplow mode, the plasma sheath is thin with a sharp current rise and drop. Our system operated in a transition mode between the snowplow and deflagration modes with early snowplow behavior and late deflagration behavior. Neutrons are produced in a plasma pinch at the gun muzzle, indicating snowplow behavior. The slug theory models overall gun behavior to experimental accuracy. Experimental results are compared to four theories for plasma sheath velocities: the Alfven collisionally limited model, the Rosenbluth model, the Fishbine saturated model and a single particle drift model. Experimental velocities vary from 10 5 to 10 6 m/s. Only the single particle drift and the slug model calculations are of the right magnitude (8 x 10 5 m/s). The Fishbine and the Rosenbluth models predict slower velocities (2 x 10 5 m/s). The Alfven model is not applicable to this system

  15. Multiscale Study of Currents Affected by Topography

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Multiscale Study of Currents Affected by Topography ...the effects of topography on the ocean general and regional circulation with a focus on the wide range of scales of interactions. The small-scale...details of the topography and the waves, eddies, drag, and turbulence it generates (at spatial scales ranging from meters to mesoscale) interact in the

  16. Measurement of charm in charged current at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Zimmermann, Tobias

    2008-12-15

    A measurement of charm production in charged current (CC) polarized electron-proton deep inelastic scattering processes with data from the H1 detector at the HERA collider is presented. This process in principle allows access to the strange quark density in the proton. In total 5460 CC candidate events in e{sup +}p and 6253 in e{sup -}p data are selected in the kinematic range Q{sup 2}>223 GeV{sup 2} and 0.03measured CC cross sections are {sigma}{sub CC}=(28.9{+-} 1.4)+P{sub e}.(28.6{+-}4.7) pb for e{sup +}p and {sigma}{sub CC}=(49.2{+-}2.3)-P{sub e}.(42.5 {+-}6.8) pb for e{sup -}p, where P{sub e} is the lepton beam polarization. While the measured cross section for e{sup +}p data is in agreement with the theoretical prediction, the cross section for e{sup -}p data shows a weaker dependence on P{sub e} than predicted. The charm fractions in the selected CC candidate event samples are extracted using the muon charge asymmetry. Muons originating from charmed hadron decays in CC events at HERA always have the same charge as the beam lepton. The extracted charm fractions in the selected CC candidate event samples are F{sub c}=9.5{+-}8.9{+-}3.0 % for e{sup +}p and F{sub c}=4.4{+-}6.9{+-}2.6 % for e{sup -}p. Due to the large statistical errors of the measured charm fractions, the strange quark density in the proton has not been extracted. (orig.)

  17. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  18. Critical current studies of a HTS rectangular coil

    Energy Technology Data Exchange (ETDEWEB)

    Zhong, Z. [Department of Engineering, University of Cambridge (United Kingdom); Chudy, M., E-mail: Michal.chudy@stuba.sk [Graduate School of Technology Management, University of Pretoria (South Africa); Institute of Power and Applied Electrical Engineering, Slovak University of Technology in Bratislava (Slovakia); Ruiz, H.S. [Department of Engineering, University of Leicester, Leicester LE1 7RH (United Kingdom); Zhang, X.; Coombs, T. [Department of Engineering, University of Cambridge (United Kingdom)

    2017-05-15

    Highlights: • Unique square pancake coil was manufactured. • Measurements in relatively high magnetic field were performed. • Different sections of the coil were characterized. • Parts of the coil which are limiting critical current were identified. - Abstract: Nowadays, superconducting high field magnets are used in numerous applications due to their superior properties. High temperature superconductors (HTS) are usually used for production of circular pancake or racetrack coils. However different geometries of HTS coils might be required for some specific applications. In this study, the HTS coil wound on a rectangular frame was fully characterized in homogeneous DC background field. The study contains measurements of critical current angular dependencies. The critical current of the entire coil and two selected strands under different magnitudes and orientations of external magnetic fields are measured. The critical regions of the coil in different angular regimes are determined. This study brings better understanding of the in- field performance of HTS coils wound on frames with right-angles.

  19. Measurement of charm in charged current at HERA

    International Nuclear Information System (INIS)

    Zimmermann, Tobias

    2008-12-01

    A measurement of charm production in charged current (CC) polarized electron-proton deep inelastic scattering processes with data from the H1 detector at the HERA collider is presented. This process in principle allows access to the strange quark density in the proton. In total 5460 CC candidate events in e + p and 6253 in e - p data are selected in the kinematic range Q 2 >223 GeV 2 and 0.03 CC =(28.9± 1.4)+P e .(28.6±4.7) pb for e + p and σ CC =(49.2±2.3)-P e .(42.5 ±6.8) pb for e - p, where P e is the lepton beam polarization. While the measured cross section for e + p data is in agreement with the theoretical prediction, the cross section for e - p data shows a weaker dependence on P e than predicted. The charm fractions in the selected CC candidate event samples are extracted using the muon charge asymmetry. Muons originating from charmed hadron decays in CC events at HERA always have the same charge as the beam lepton. The extracted charm fractions in the selected CC candidate event samples are F c =9.5±8.9±3.0 % for e + p and F c =4.4±6.9±2.6 % for e - p. Due to the large statistical errors of the measured charm fractions, the strange quark density in the proton has not been extracted. (orig.)

  20. Feedwater flow measurements: challenges, current solutions, and 'soft' developments

    International Nuclear Information System (INIS)

    Ruan, D.; Roverso, D.; Fantoni, P.F.; Sanabrias, J.I.; Carrasco, J.A.; Fernandez, L.

    2002-07-01

    This report presents an early progress of a feasibility study of a computational intelligence approach to the enhancement of the accuracy of feedwater flow measurements in the framework of an ongoing cooperation between Tecnatom s.a. in Madrid and the OECD Halden Reactor Project (HRP) in Halden. The aim of this research project is to contribute to the development and validation of a flow sensor in a nuclear power plant (NPP). The basic idea is to combine the use of applied computational intelligence approaches (noise analysis, neural networks, fuzzy systems, wavelets etc.) with existing traditional flow measurements, and in particular with cross correlation flow meter concepts. In this report, Section 2 outlines relevant aspects of thermal power calculations on electrical power plants. Section 3 reviews from the available literature possible approaches and solutions for feedwater flow measurement, including ultrasonic flow meters, cross-correlation flow meters, and 'Virtural' flow meters with artificial neural networks. Section 4 reports typical experimental measurements at the Tecnatom's facility. Section 5 presents an integration approach and preliminary experimental tests. Section 6 discusses the role of soft computing techniques in the context of feedwater flow measurements related nuclear fields, and Section 7 highlights the future research direction. (Author)

  1. Measuring physical inactivity: do current measures provide an accurate view of "sedentary" video game time?

    Science.gov (United States)

    Fullerton, Simon; Taylor, Anne W; Dal Grande, Eleonora; Berry, Narelle

    2014-01-01

    Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames) can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n = 2026) were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children's video game time. A substantial proportion of time that would usually be classified as "sedentary" may actually be spent participating in light to moderate physical activity.

  2. Electron and current density measurements on tokamak plasmas

    International Nuclear Information System (INIS)

    Lammeren, A.C.A.P. van.

    1991-01-01

    The first part of this thesis describes the Thomson-scattering diagnostic as it was present at the TORTUR tokamak. For the first time with this diagnostic a complete tangential scattering spectrum was recorded during one single laser pulse. From this scattering spectrum the local current density was derived. Small deviations from the expected gaussian scattering spectrum were observed indicating the non-Maxwellian character of the electron-velocity distribution. The second part of this thesis describes the multi-channel interferometer/ polarimeter diagnostic which was constructed, build and operated on the Rijnhuizen Tokamak Project (RTP) tokamak. The diagnostic was operated routinely, yielding the development of the density profiles for every discharge. When ECRH (Electron Cyclotron Resonance Heating) is switched on the density profile broadens, the central density decreases and the total density increases, the opposite takes place when ECRH is switched off. The influence of MHD (magnetohydrodynamics) activity on the density was clearly observable. In the central region of the plasma it was measured that in hydrogen discharges the so-called sawtooth collapse is preceded by an m=1 instability which grows rapidly. An increase in radius of this m=1 mode of 1.5 cm just before the crash is observed. In hydrogen discharges the sawtooth induced density pulse shows an asymmetry for the high- and low-field side propagation. This asymmetry disappeared for helium discharges. From the location of the maximum density variations during an m=2 mode the position of the q=2 surface is derived. The density profiles are measured during the energy quench phase of a plasma disruption. A fast flattening and broadening of the density profile is observed. (author). 95 refs.; 66 figs.; 7 tabs

  3. Current measurements over the western continental shelf of India

    Digital Repository Service at National Institute of Oceanography (India)

    Shenoi, S.S.C.; Antony, M.K.

    south during May and March and towards north during November. The spectral analysis indicates that the inertial and semidiurnal frequency motions are the major contributors to the current structure. The inertial currents were concentrated near...

  4. Depletion region surface effects in electron beam induced current measurements

    Energy Technology Data Exchange (ETDEWEB)

    Haney, Paul M.; Zhitenev, Nikolai B. [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Yoon, Heayoung P. [Department of Electrical and Computer Engineering, University of Utah, Salt Lake City, Utah 84112 (United States); Gaury, Benoit [Center for Nanoscale Science and Technology, National Institute of Standards and Technology, Gaithersburg, Maryland 20899 (United States); Maryland NanoCenter, University of Maryland, College Park, Maryland 20742 (United States)

    2016-09-07

    Electron beam induced current (EBIC) is a powerful characterization technique which offers the high spatial resolution needed to study polycrystalline solar cells. Current models of EBIC assume that excitations in the p-n junction depletion region result in perfect charge collection efficiency. However, we find that in CdTe and Si samples prepared by focused ion beam (FIB) milling, there is a reduced and nonuniform EBIC lineshape for excitations in the depletion region. Motivated by this, we present a model of the EBIC response for excitations in the depletion region which includes the effects of surface recombination from both charge-neutral and charged surfaces. For neutral surfaces, we present a simple analytical formula which describes the numerical data well, while the charged surface response depends qualitatively on the location of the surface Fermi level relative to the bulk Fermi level. We find that the experimental data on FIB-prepared Si solar cells are most consistent with a charged surface and discuss the implications for EBIC experiments on polycrystalline materials.

  5. Study of the Weak Charged Hadronic Current in b Decays

    CERN Document Server

    Acciarri, M; Aguilar-Benítez, M; Ahlen, S P; Alpat, B; Alcaraz, J; Alemanni, G; Allaby, James V; Aloisio, A; Alverson, G; Alviggi, M G; Ambrosi, G; Anderhub, H; Andreev, V P; Angelescu, T; Anselmo, F; Antreasyan, D; Arefev, A; Azemoon, T; Aziz, T; Bagnaia, P; Baksay, L; Ball, R C; Banerjee, S; Banicz, K; Barillère, R; Barone, L; Bartalini, P; Baschirotto, A; Basile, M; Battiston, R; Bay, A; Becattini, F; Becker, U; Behner, F; Berdugo, J; Berges, P; Bertucci, B; Betev, B L; Bhattacharya, S; Biasini, M; Biland, A; Bilei, G M; Blaising, J J; Blyth, S C; Bobbink, Gerjan J; Böck, R K; Böhm, A; Borgia, B; Boucham, A; Bourilkov, D; Bourquin, Maurice; Boutigny, D; Branson, J G; Brigljevic, V; Brock, I C; Buffini, A; Buijs, A; Burger, J D; Burger, W J; Busenitz, J K; Buytenhuijs, A O; Cai, X D; Campanelli, M; Capell, M; Cara Romeo, G; Caria, M; Carlino, G; Cartacci, A M; Casaus, J; Castellini, G; Cavallari, F; Cavallo, N; Cecchi, C; Cerrada-Canales, M; Cesaroni, F; Chamizo-Llatas, M; Chan, A; Chang, Y H; Chaturvedi, U K; Chemarin, M; Chen, A; Chen, G; Chen, G M; Chen, H F; Chen, H S; Chen, M; Chiefari, G; Chien, C Y; Choi, M T; Cifarelli, Luisa; Cindolo, F; Civinini, C; Clare, I; Clare, R; Cohn, H O; Coignet, G; Colijn, A P; Colino, N; Commichau, V; Costantini, S; Cotorobai, F; de la Cruz, B; Csilling, Akos; Dai, T S; D'Alessandro, R; De Asmundis, R; De Boeck, H; Degré, A; Deiters, K; Denes, P; De Notaristefani, F; DiBitonto, Daryl; Diemoz, M; Van Dierendonck, D N; Di Lodovico, F; Dionisi, C; Dittmar, Michael; Dominguez, A; Doria, A; Dorne, I; Dova, M T; Drago, E; Duchesneau, D; Duinker, P; Durán, I; Dutta, S; Easo, S; Efremenko, Yu V; El-Mamouni, H; Engler, A; Eppling, F J; Erné, F C; Ernenwein, J P; Extermann, Pierre; Fabre, M; Faccini, R; Falciano, S; Favara, A; Fay, J; Fedin, O; Felcini, Marta; Fenyi, B; Ferguson, T; Fernández, D; Ferroni, F; Fesefeldt, H S; Fiandrini, E; Field, J H; Filthaut, Frank; Fisher, P H; Forconi, G; Fredj, L; Freudenreich, Klaus; Furetta, C; Galaktionov, Yu; Ganguli, S N; García-Abia, P; Gau, S S; Gentile, S; Gerald, J; Gheordanescu, N; Giagu, S; Goldfarb, S; Goldstein, J; Gong, Z F; Gougas, Andreas; Gratta, Giorgio; Grünewald, M W; Gupta, V K; Gurtu, A; Gutay, L J; Hartmann, B; Hasan, A; Hatzifotiadou, D; Hebbeker, T; Hervé, A; Van Hoek, W C; Hofer, H; Hoorani, H; Hou, S R; Hu, G; Innocente, Vincenzo; Janssen, H; Jenkes, K; Jin, B N; Jones, L W; de Jong, P; Josa-Mutuberria, I; Kasser, A; Khan, R A; Kamrad, D; Kamyshkov, Yu A; Kapustinsky, J S; Karyotakis, Yu; Kaur, M; Kienzle-Focacci, M N; Kim, D; Kim, J K; Kim, S C; Kim, Y G; Kinnison, W W; Kirkby, A; Kirkby, D; Kirkby, Jasper; Kiss, D; Kittel, E W; Klimentov, A; König, A C; Korolko, I; Koutsenko, V F; Krämer, R W; Krenz, W; Kuijten, H; Kunin, A; Ladrón de Guevara, P; Landi, G; Lapoint, C; Lassila-Perini, K M; Laurikainen, P; Lebeau, M; Lebedev, A; Lebrun, P; Lecomte, P; Lecoq, P; Le Coultre, P; Lee Jae Sik; Lee, K Y; Leggett, C; Le Goff, J M; Leiste, R; Leonardi, E; Levchenko, P M; Li Chuan; Lieb, E H; Lin, W T; Linde, Frank L; Lista, L; Liu, Z A; Lohmann, W; Longo, E; Lu, W; Lü, Y S; Lübelsmeyer, K; Luci, C; Luckey, D; Luminari, L; Lustermann, W; Ma Wen Gan; Maity, M; Majumder, G; Malgeri, L; Malinin, A; Maña, C; Mangla, S; Marchesini, P A; Marin, A; Martin, J P; Marzano, F; Massaro, G G G; McNally, D; Mele, S; Merola, L; Meschini, M; Metzger, W J; Von der Mey, M; Mi, Y; Mihul, A; Van Mil, A J W; Mirabelli, G; Mnich, J; Molnár, P; Monteleoni, B; Moore, R; Morganti, S; Moulik, T; Mount, R; Müller, S; Muheim, F; Nagy, E; Nahn, S; Napolitano, M; Nessi-Tedaldi, F; Newman, H; Nippe, A; Nisati, A; Nowak, H; Opitz, H; Organtini, G; Ostonen, R; Pandoulas, D; Paoletti, S; Paolucci, P; Park, H K; Pascale, G; Passaleva, G; Patricelli, S; Paul, T; Pauluzzi, M; Paus, C; Pauss, Felicitas; Peach, D; Pei, Y J; Pensotti, S; Perret-Gallix, D; Petrak, S; Pevsner, A; Piccolo, D; Pieri, M; Pinto, J C; Piroué, P A; Pistolesi, E; Plyaskin, V; Pohl, M; Pozhidaev, V; Postema, H; Produit, N; Prokofev, D; Prokofiev, D O; Rahal-Callot, G; Rancoita, P G; Rattaggi, M; Raven, G; Razis, P A; Read, K; Ren, D; Rescigno, M; Reucroft, S; Van Rhee, T; Riemann, S; Riemers, B C; Riles, K; Rind, O; Ro, S; Robohm, A; Rodin, J; Rodríguez-Calonge, F J; Roe, B P; Romero, L; Rosier-Lees, S; Rosselet, P; Van Rossum, W; Roth, S; Rubio, Juan Antonio; Rykaczewski, H; Salicio, J; Sánchez, E; Santocchia, A; Sarakinos, M E; Sarkar, S; Sassowsky, M; Sauvage, G; Schäfer, C; Shchegelskii, V; Schmidt-Kärst, S; Schmitz, D; Schmitz, P; Schneegans, M; Scholz, N; Schopper, Herwig Franz; Schotanus, D J; Schwenke, J; Schwering, G; Sciacca, C; Sciarrino, D; Sens, Johannes C; Servoli, L; Shevchenko, S; Shivarov, N; Shoutko, V; Shukla, J; Shumilov, E; Shvorob, A V; Siedenburg, T; Son, D; Sopczak, André; Soulimov, V; Smith, B; Spillantini, P; Steuer, M; Stickland, D P; Stone, H; Stoyanov, B; Strässner, A; Strauch, K; Sudhakar, K; Sultanov, G G; Sun, L Z; Susinno, G F; Suter, H; Swain, J D; Tang, X W; Tauscher, Ludwig; Taylor, L; Ting, Samuel C C; Ting, S M; Tonutti, M; Tonwar, S C; Tóth, J; Tully, C; Tuchscherer, H; Tung, K L; Uchida, Y; Ulbricht, J; Uwer, U; Valente, E; Van de Walle, R T; Vesztergombi, G; Vetlitskii, I; Viertel, Gert M; Vivargent, M; Völkert, R; Vogel, H; Vogt, H; Vorobev, I; Vorobyov, A A; Vorvolakos, A; Wadhwa, M; Wallraff, W; Wang, J C; Wang, X L; Wang, Z M; Weber, A; Wittgenstein, F; Wu, S X; Wynhoff, S; Xu, J; Xu, Z Z; Yang, B Z; Yang, C G; Yao, X Y; Ye, J B; Yeh, S C; You, J M; Zalite, A; Zalite, Yu; Zemp, P; Zeng, Y; Zhang, Z; Zhang, Z P; Zhou, B; Zhou, Y; Zhu, G Y; Zhu, R Y; Zichichi, Antonino; Ziegler, F

    1997-01-01

    Charged and neutral particle multiplicities of jets associated with identified semileptonic and hadronic b decays are studied. The observed differences between these jets are used to determine the inclusive properties of the weak charged hadronic current. The average charged particle multiplicity of the weak charged hadronic current in b decays is measured for the first time to be 2.69$\\pm$0.07(stat.)$\\pm$0.14(syst.). This result is in good agreement with the JETSET hadronization model of the weak charged hadronic current if 40$\\pm$17\\% of the produced mesons are light--flavored tensor (L=1) mesons. This level of tensor meson production is consistent with the measurement of the $\\pi^0$ multiplicity in the weak charged hadronic current in b decays. \\end{abstract}

  6. Determining the near-surface current profile from measurements of the wave dispersion relation

    Science.gov (United States)

    Smeltzer, Benjamin; Maxwell, Peter; Aesøy, Eirik; Ellingsen, Simen

    2017-11-01

    The current-induced Doppler shifts of waves can yield information about the background mean flow, providing an attractive method of inferring the current profile in the upper layer of the ocean. We present measurements of waves propagating on shear currents in a laboratory water channel, as well as theoretical investigations of inversion techniques for determining the vertical current structure. Spatial and temporal measurements of the free surface profile obtained using a synthetic Schlieren method are analyzed to determine the wave dispersion relation and Doppler shifts as a function of wavelength. The vertical current profile can then be inferred from the Doppler shifts using an inversion algorithm. Most existing algorithms rely on a priori assumptions of the shape of the current profile, and developing a method that uses less stringent assumptions is a focus of this study, allowing for measurement of more general current profiles. The accuracy of current inversion algorithms are evaluated by comparison to measurements of the mean flow profile from particle image velocimetry (PIV), and a discussion of the sensitivity to errors in the Doppler shifts is presented.

  7. MEASUREMENTS AND MODELING OF EDDY CURRENT EFFECTS IN BNL'S AGS BOOSTER

    International Nuclear Information System (INIS)

    BROWN, K.A.; AHRENS, L.; GARDNER, C.; GLENN, J.W.; HARVEY, M.; MENG, W.; ZENO, K.

    2006-01-01

    Recent beam experiments at BNL's AGS Booster have enabled us to study in more detail the effects of eddy currents on the lattice structure and our control over the betatron tune. The Booster is capable of operating at ramp rates as high as 9 T/sec. At these ramp rates eddy currents in the vacuum chambers significantly alter the fields and gradients seen by the beam as it is accelerated. The Booster was designed with these effects in mind and to help control the field uniformity and linearity in the Booster Dipoles special vacuum chambers were designed with current windings to negate the affect of the induced eddy currents. In this report results from betatron tune measurements and eddy current simulations will be presented. We will then present results from modeling the accelerator using the results of the magnetic field simulations and compare these to the measurements

  8. Current status of decay heat measurements, evaluations, and needs

    International Nuclear Information System (INIS)

    Dickens, J.K.

    1986-01-01

    Over a decade ago serious concern over possible consequences of a loss-of-coolant accident in a commercial light-water reactor prompted support of several experiments designed specifically to measure the latent energy of beta-ray and gamma-ray emanations from fission products for thermal reactors. This latent energy was termed Decay Heat. At about the same time the American Nuclear Society convened a working group to develop a standard for use in computing decay heat in real reactor environs primarily for regulatory requirements. This working group combined the new experimental results and best evaluated data into a standard which was approved by the ANS and by the ANSI. The primary work since then has been (a) on improvements to computational efforts and (b) experimental measurements for fast reactors. In addition, the need for decay-heat data has been extended well beyond the time regime of a loss-of-coolant accident; new concerns involve, for example, away-from-reactor shipments and storage. The efficacy of the ANS standard for these longer time regimes has been a subject of study with generally positive results. However, a specific problem, namely, the consequences of fission-product neutron capture, remains contentious. Satisfactory resolution of this problem merits a high priority. 31 refs

  9. Short Report: New use of current technology to measure rectal ...

    African Journals Online (AJOL)

    South African Journal of Sports Medicine. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 17, No 1 (2005) >. Log in or Register to get access to full text downloads.

  10. Radon measurement studies in Kazakhstan

    International Nuclear Information System (INIS)

    Sevost'yanov, V.N.

    2003-01-01

    Today, one has to admit that despite the important role and certain achievements in providing the radiation control in Kazakhstan, radon measurements still present some problems related to clear definition of physical quantities applied, correct use of methods, and application of adequate measuring devices to meet requirements of regulatory documents currently in effect, such as NRB-99. The paper provides some data on radon measurements, describes the problem status in Kazakhstan and proposes ways to solve it. (author)

  11. ADCP measurements of gravity currents in the Chicago River, Illinois

    Science.gov (United States)

    Garcia, C.M.; Oberg, K.; Garcia, M.H.

    2007-01-01

    A unique set of observations of stratified flow phenomena in the Chicago River was made using an upward-looking acoustic Doppler current profiler (ADCP) during the period November 20, 2003 to February 1, 2004. Water density differences between the Chicago River and its North Branch (NB) seem to be responsible for the development of gravity currents. With the objective of characterizing the occurrence, frequency, and evolution of such currents, the ADCP was configured to continuously collect high-resolution water velocity and echo intensity profiles in the Chicago River at Columbus Drive. During the observation period, 28 gravity current events were identified, lasting a total of 77% of the time. Sixteen of these events were generated by underflows from the NB and 12 of these events were generated by overflows from the NB. On average, the duration of the underflow and overflow events was 52.3 and 42.1 h, respectively. A detailed analysis of one underflow event, which started on January 7, 2004, and lasted about 65h, was performed. This is the first time that ADCP technology has been used to continuously monitor gravity currents in a river. ?? 2007 ASCE.

  12. Interlaboratory comparison on high-temperature superconductor critical-current measurements

    International Nuclear Information System (INIS)

    Wiejaczka, J.A.; Goodrich, L.F.

    1997-01-01

    An extensive interlaboratory comparison was conducted on high temperature superconductor (HTS) critical-current measurements. This study was part of an international cooperative effort through the Versailles Project on Advanced Materials and Standards (VAMAS). The study involved six US laboratories that are recognized leaders in the field of HTS. This paper includes the complete results from this comparison of critical-current measurements on Ag-sheathed Bi 2 Sr 2 Ca 2 Cu 3 O 10-x (2223) tapes. The effects of sample characteristics, specimen mounting, measurement technique, and specimen damage were studied. The future development of a standard HTS measurement method is also discussed. Most of the evolution of this emerging technology has occurred in improvement of the performance of the conductors. The successful completion of this interlaboratory comparison is an important milestone in the evolution of HTS technology and marks a level of maturity that the technology has reached

  13. Study of the space-time structure of the leptonic weak charged current by measurement of the muon polarization from the reaction anti νsub(μ)+Fe->X+μ+

    International Nuclear Information System (INIS)

    Metz, E.

    1982-01-01

    An experiment for the measurement of the longitudinal polarization of muons was performed which were produced in the deep inelastic anti ν-nucleon scattering in an irontarget (CDHS detector). The muon decay was applied as indicator of the muon polarization. As polarimeter served a marmor-scintillator calorimeter (CHARM detector). The experiment was performed in the broad-band beam of the CERN SPS. Measured was the longitudinal polarization P = 0.82 +- 0.07 (stat.) +- 0.12 (syst.). That means that the weak charged current possesses a dominant vector and/or axial-vector structure. Regarding the measuring errors of the muon polarization an upper limit for possible S-, P-, and T- contributions to the weak charged current can be stated: sigmasub(S,P,T)/sigmasub(TOT) 0.5) relatively to the muon polarization for small y (y 0.5) = 1.10 +- 0.24 (stat.). The systematic error vanishes in this relative measurement. Measured value and error lead to an upper limit for S- and/or P-contributions: sigmasub(S,P):sigmasub(TOT) 2 approx.= 4 (GeV/c) 2 ) a vector and/or axial-vector structure. (orig./HSI) [de

  14. On the Current Measurement Practices in Agile Software Development

    OpenAIRE

    Javdani, Taghi; Zulzalil, Hazura; Ghani, Abdul Azim Abd; Sultan, Abu Bakar Md; Parizi, Reza Meimandi

    2013-01-01

    Agile software development (ASD) methods were introduced as a reaction to traditional software development methods. Principles of these methods are different from traditional methods and so there are some different processes and activities in agile methods comparing to traditional methods. Thus ASD methods require different measurement practices comparing to traditional methods. Agile teams often do their projects in the simplest and most effective way so, measurement practices in agile metho...

  15. TID-dependent current measurements of IBL readout chips

    Energy Technology Data Exchange (ETDEWEB)

    Dette, Karola [TU Dortmund, Experimentelle Physik IV (Germany); CERN (Switzerland); Collaboration: ATLAS Pixel-Collaboration

    2016-07-01

    The ATLAS detector consists of several subsystems with a hybrid pixel detector as the innermost component of the tracking system. The pixel detector has been composed of three layers of silicon sensor assemblies during the first data taking run of the LHC and has been upgraded with a new 4th layer, the so-called Insertable B-Layer (IBL), in summer 2014. Each silicon sensor of the IBL is connected to a Front End readout chip (FE-I4) via bump bonds. During the first year of data taking an increase of the LV current produced by the readout chips was observed. This increase could be traced back to radiation damage inside the silicon. The dependence of the current on the Total Ionizing Dose (TID) and temperature has been tested with X-ray irradiations and will be presented in this talk.

  16. Measurement of direct currents of under 10-10 ampere and of resistances of 1012 Ω for a direct current

    International Nuclear Information System (INIS)

    Vagner, J.

    1965-01-01

    Measurement of weak direct currents by Townsend's method using a vibrating condenser electrometer. Development of a current generator giving a pico-ampere independently of the resistance of the circuit used. Development of generators giving currents which may be adjusted continuously and exactly (0.1 to 1 pico-ampere, 1 to 10 pico-amperes, 10 to 100 pico-amperes). Measurement of very high resistances (10 12 Ω) by three different methods. Graphs are made by plotting the value of the resistance against the potential difference applied across it (from 50 milli-volts to 50 volts). Two methods use adjustable current generators and the third is applicable to the measurement of resistances of between 10 7 and 10 13 Ω using a series of condensers ranging from 50 pico-farads to 10 micro-farads. The accuracy of the measurements is between 0. 5 and 1 per cent. (author) [fr

  17. The Current Canon in British Romantics Studies.

    Science.gov (United States)

    Linkin, Harriet Kramer

    1991-01-01

    Describes and reports on a survey of 164 U.S. universities to ascertain what is taught as the current canon of British Romantic literature. Asserts that the canon may now include Mary Shelley with the former standard six major male Romantic poets, indicating a significant emergence of a feminist perspective on British Romanticism in the classroom.…

  18. Measuring child exposure to violence and mental health reactions in epidemiological studies: challenges and current issues Criança, violência e saúde: desafios e questões atuais

    Directory of Open Access Journals (Sweden)

    Cristiane Seixas Duarte

    2009-04-01

    Full Text Available This paper examines challenges and current issues involved in measuring exposure to different types of violence which are associated mental health problems in children and adolescents. Standardized measures suitable for epidemiological studies, selected based on their relevance in the current literature, are briefly described and commented. The assessment of child's exposure to violence may focus on a specific event (e.g., kidnapping, a specific context (e.g., war or even of a certain type of exposure (e.g., intrafamilial physical violence. The assessment of child mental health after exposure to violence has traditionally focused on posttraumatic stress disorder (PTSD - most frequently measured through non-diagnostic scales. However, other mental health reactions may be present and screening as well as diagnostic instruments which may be used to assess these reactions are also described. Two issues of emerging importance - the assessment of impairment and of traumatic grief in children - are also presented. Availability of culturally appropriate instruments is a crucial step towards proper identification of child mental health problems after exposure to violence.Este artigo examina os desafios e perspectivas atuais envolvidos na mensuração da exposição a diferentes tipos de violência e problemas de saúde mental em crianças e adolescentes. Instrumentos padronizados apropriados para estudos epidemiológicos, selecionados com base em sua relevância na literatura, são brevemente descritos e comentados. A avaliação de exposição à violência em crianças pode dizer respeito a um evento específico (como sequestro ou um contexto específico (como guerra ou mesmo um determinado tipo de exposição (como violência física intrafamiliar. A avaliação da saúde mental infantil após a exposição à violência tradicionalmente concentrou-se na avaliação do transtorno de estresse pós-traumático (TEPT - freqüentemente avaliado atrav

  19. Measurements of monopolar and bipolar current spreads using forward-masking with a fixed probe.

    Science.gov (United States)

    Bingabr, Mohamed G; Espinoza-Varas, Blas; Sigdel, Saroj

    2014-05-01

    This research employed a forward-masking paradigm to estimate the current spread of monopolar (MP) and bipolar (BP) maskers, with current amplitudes adjusted to elicit the same loudness. Since the spatial separation between active and return electrodes is smaller in BP than in MP configurations, the BP current spread is more localized and presumably superior in terms of speech intelligibility. Because matching the loudness requires higher current in BP than in MP stimulation, previous forward-masking studies show that BP current spread is not consistently narrower across subjects or electrodes within a subject. The present forward-masking measures of current spread differ from those of previous studies by using the same BP probe electrode configuration for both MP and BP masker configurations, and adjusting the current levels of the MP and BP maskers so as to match them in loudness. With this method, the estimate of masker current spread would not be contaminated by differences in probe current spread. Forward masking was studied in four cochlear implant patients, two females and two males, with speech recognition scores higher than 50%; that is, their auditory-nerve survival status was more than adequate to carry out the experiments. The data showed that MP and BP masker configurations produce equivalent masking patterns (and current spreads) in three participants. A fourth participant displayed asymmetrical patterns with enhancement rather than masking in some cases, especially when the probe and masker were at the same location. This study showed equivalent masking patterns for MP and BP maskers when the BP masker current amplitude was increased to match the loudness of the MP masker, and the same BP probe configuration is used with both maskers. This finding could help to explain why cochlear implant users often fail to accrue higher speech intelligibility benefit from BP stimulation.

  20. 'Leak Current' correction for critical current measurement of no-insulation HTS coil

    Energy Technology Data Exchange (ETDEWEB)

    Song, Jung Bin [Laboratoire National des Champs Magnétiques Intenses, CNRS, Grenoble (France); Hahn, Seung Yong [Dept. of Electrical and Computer Engineering, Seoul National University, Seoul (Korea, Republic of)

    2017-06-15

    Discrepancy between a power supply current and an actual “spiral” coil current makes the conventional 4-probe measurement of a critical current (I{sub c}) of a no-insulation (NI) high temperature superconductor (HTS) coil inaccurate and time-consuming. This paper presents a fast and accurate approach for I{sub c} measurement of NI HTS coils. With an NI HTS coil energized at a constant ramping rate, a complete analytic expression for the spiral coil current was obtained from a first-order partial differential equation that derived from an equivalent circuit model of the NI coil. From the analytic solution, both spiral coil current and radial leak current can be obtained simultaneously, which enables fast and accurate measurement of the NI coil I{sub c}. To verify the proposed approach, an NI double-pancake (DP) coil, wound with GdBCO tapes of 6 mm × 0.1 mm, was constructed and its Ic was repeatedly measured with various ramping rates in a bath of liquid nitrogen at 77 K. The measured results agreed well with the calculated ones, which validates the proposed approach to measure I{sub c} of an NI HTS coil.

  1. Surfzone currents at Candolim and Miramar beaches of Goa, India: measurements and comparisons

    Digital Repository Service at National Institute of Oceanography (India)

    Yadhunath, E.M.; JayaKumar, S.; Jishad, M.; Gowthaman, R.; Rajasekaran, C.; Pednekar, P.S.

    Measurements in the surfzone current are often carried out using Acoustic Doppler Velocimeters, Electromagnetic current meters, as well as visual observations based on floats A simple approach is used to install an Aanderaa current meter in water...

  2. Measurement of the depth of narrow slotted sections in eddy current reference standards

    Science.gov (United States)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  3. Current CTR-related tritium handling studies at ORNL

    International Nuclear Information System (INIS)

    Watson, J.S.; Bell, J.T.; Clinton, S.D.; Fisher, P.W.; Redman, J.D.; Smith, F.J.; Talbot, J.B.; Tung, C.P.

    1976-01-01

    The Oak Ridge National Laboratory has a comprehensive program concerned with plasma fuel recycle, tritium recovery from blankets, and tritium containment in fusion reactors. Two studies of most current interest are investigations of cryosorption pumping of hydrogen isotopes and measurements of tritium permeation rates through steam generator materials. Cryosorption pumping speeds have been measured for hydrogen, deuterium, and helium at pressures from 10 -8 torr to 3 x 10 -3 torr. Permeation rates through Incoloy 800 have been shown to be drastically reduced when the low pressure side of permeation tubes are exposed to steam. These results will be important considerations in the design of fusion reactor steam generators

  4. Measuring surface current velocities in the Agulhas region with ASAR

    CSIR Research Space (South Africa)

    Rouault, MJ

    2010-01-01

    Full Text Available is known to perform well. Although radial velocities derived from ASAR are on occasion able to represent the measured flow with incredible accuracy, the overall performance of the ASAR radial velocity product is negatively impacted by a few very large...

  5. Comparison of current tonometry techniques in measurement of intraocular pressure

    Directory of Open Access Journals (Sweden)

    Behrooz Kouchaki

    2017-06-01

    Conclusion: Although the mean difference of measured IOP by NCT, DCT, and ORA with GAT was less than 2 mmHg, the limit of agreement was relatively large. CCT and CRF were important influencing factors in the four types of tonometers.

  6. Measuring Plasma Formation Field Strength and Current Loss in Pulsed Power Diodes

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Patel, Sonal G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Falcon, Ross Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cartwright, Keith [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Kiefer, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cuneo, Michael E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Maron, Yitzhak [Weizmann Inst. of Science, Rehovot (Israel)

    2017-11-01

    This LDRD investigated plasma formation, field strength, and current loss in pulsed power diodes. In particular the Self-Magnetic Pinch (SMP) e-beam diode was studied on the RITS-6 accelerator. Magnetic fields of a few Tesla and electric fields of several MV/cm were measured using visible spectroscopy techniques. The magnetic field measurements were then used to determine the current distribution in the diode. This distribution showed that significant beam current extends radially beyond the few millimeter x-ray focal spot diameter. Additionally, shielding of the magnetic field due to dense electrode surface plasmas was observed, quantified, and found to be consistent with the calculated Spitzer resistivity. In addition to the work on RITS, measurements were also made on the Z-machine looking to quantify plasmas within the power flow regions. Measurements were taken in the post-hole convolute and final feed gap regions on Z. Dopants were applied to power flow surfaces and measured spectroscopically. These measurements gave species and density/temperature estimates. Preliminary B-field measurements in the load region were attempted as well. Finally, simulation work using the EMPHASIS, electromagnetic particle in cell code, was conducted using the Z MITL conditions. The purpose of these simulations was to investigate several surface plasma generations models under Z conditions for comparison with experimental data.

  7. Infectious bronchitis virus variants ? History, current situation and control measures

    OpenAIRE

    2011-01-01

    Abstract Infectious bronchitis virus (IBV) is ubiquitous in most parts of the world where poultry are reared and is able to spread very rapidly in non-protected birds. It is shed via both the respiratory tract and the faeces and can persist in the birds and the intestinal tract for several weeks or months. Outdoors, survival of IBV for 56 days in litter has been reported. Although strict biosecurity and working with a one-age system are essential control measures, normally vaccinat...

  8. Measuring current emission and work functions of large thermionic cathodes

    International Nuclear Information System (INIS)

    Fortgang, C.M.

    2001-01-01

    As one component of the nations Stockpile Stewardship program, Los Alamos National Laboratory is constructing a 20 MeV, 2 kA (with a 4 kA upgrade capability), 3ps induction linac for doing x-ray radiography of explosive devices. The linac is one leg of a facility called the Dual-Axis Radiography Hydrodynamic Test Facility (DARHT). The electron gun is designed to operate at 3.2 MV. The gun is a Pierce type design and uses a 6.5' cathode for 2 kA operation and an 8' cathode for 4 kA operation. We have constructed a small facility called the Cathode Test Stand (CTS) to investigate engineering and physics issues regarding large thermionic dispenser-cathodes. In particular, we have looked at the issues of temperature uniformity on the cathode surface and cathode quality as measured by its work function. We have done thermal imaging of both 8' and 6.5' cathodes. Here we report on measurements of the cathode work function, both the average value and how it vanes across the face of the cathode.

  9. An optimized Faraday cage design for electron beam current measurements

    International Nuclear Information System (INIS)

    Turner, J.N.; Hausner, G.G.; Parsons, D.F.

    1975-01-01

    A Faraday cage detector is described for measuring electron beam intensity for use with energies up to 1.2 Mev, with the present data taken at 100 keV. The design features a readily changeable limiting aperture and detector cup geometry, and a secondary electron suppression grid. The detection efficiency of the cage is shown to be limited only by primary backscatter through the detector solid angle of escape, which is optimized with respect to primary backscattered electrons and secondary electron escape. The geometry and stopping material of the detection cup are varied, and the results show that for maximum detection efficiency with carbon as the stopping mateiral, the solid angle of escape must be equal to or less than 0.05πsr. The experimental results are consistent within the +-2% accuracy of the detection electronics, and are not limited by the Faraday cage detection efficiency. (author)

  10. Contactless measurement of alternating current conductance in quantum Hall structures

    Energy Technology Data Exchange (ETDEWEB)

    Drichko, I. L.; Diakonov, A. M.; Malysh, V. A.; Smirnov, I. Yu.; Ilyinskaya, N. D.; Usikova, A. A. [A. F. Ioffe Physical-Technical Institute of the Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Galperin, Y. M. [Department of Physics, University of Oslo, P.O. Box 1048 Blindern, 0316 Oslo (Norway); A. F. Ioffe Physical-Technical Institute of the Russian Academy of Sciences, 194021 St. Petersburg (Russian Federation); Kummer, M.; Känel, H. von [Laboratorium für Festkörperphysik ETH Zürich, CH-8093 Zürich (Switzerland)

    2014-10-21

    We report a procedure to determine the frequency-dependent conductance of quantum Hall structures in a broad frequency domain. The procedure is based on the combination of two known probeless methods—acoustic spectroscopy and microwave spectroscopy. By using the acoustic spectroscopy, we study the low-frequency attenuation and phase shift of a surface acoustic wave in a piezoelectric crystal in the vicinity of the electron (hole) layer. The electronic contribution is resolved using its dependence on a transverse magnetic field. At high frequencies, we study the attenuation of an electromagnetic wave in a coplanar waveguide. To quantitatively calibrate these data, we use the fact that in the quantum-Hall-effect regime the conductance at the maxima of its magnetic field dependence is determined by extended states. Therefore, it should be frequency independent in a broad frequency domain. The procedure is verified by studies of a well-characterized p-SiGe/Ge/SiGe heterostructure.

  11. Relation of field-aligned currents measured by AMPERE project to solar wind and substorms

    Science.gov (United States)

    McPherron, R. L.; Anderson, B. J.; Chu, X.

    2016-12-01

    Magnetic perturbations measured in the Active Magnetosphere and Planetary Electrodynamics Response Experiment (AMPERE) by the Iridium constellation of spacecraft have been processed to obtain the time history of field-aligned currents (FAC) connecting the magnetosphere to the ionosphere. We find that the strength of these currents is closely related to the strength of the solar wind driver defined as a running average of the previous three hours of the optimum AL (auroral lower) coupling function. The relation is well represented by a saturation model I = A*S*Ss/(S+Ss) with I the current strength in mega Amps, S the driver strength in mV/m, Ss the saturation value of 7.78 mV/m, and A = 2.55 scales the relation to units of current. We also find that in general the upward current on the nightside increases with each substorm expansion onset defined by a combination of the SuperMag SML (SuperMag AL) and midlatitude positive bay (MPB) onset lists. A superposed epoch analysis using 700 onsets in 2010 shows the following: solar wind coupling peaks at expansion onset; dayside outward current starts to increase one hour before onset while nightside outward current starts suddenly at onset; nightside outward current reaches a peak at 28 minutes as do SML and MPB indices; FAC, SML, and MPB respectively take 1, 2, and 3 hours to decay to background. The data indicate that the substorm current wedge is superposed on a pre-existing field-aligned current system and that the location and properties of the current wedge can be studied with the AMPERE data.

  12. Direct Reconstruction of Two-Dimensional Currents in Thin Films from Magnetic-Field Measurements

    Science.gov (United States)

    Meltzer, Alexander Y.; Levin, Eitan; Zeldov, Eli

    2017-12-01

    An accurate determination of microscopic transport and magnetization currents is of central importance for the study of the electric properties of low-dimensional materials and interfaces, of superconducting thin films, and of electronic devices. Current distribution is usually derived from the measurement of the perpendicular component of the magnetic field above the surface of the sample, followed by numerical inversion of the Biot-Savart law. The inversion is commonly obtained by deriving the current stream function g , which is then differentiated in order to obtain the current distribution. However, this two-step procedure requires filtering at each step and, as a result, oversmooths the solution. To avoid this oversmoothing, we develop a direct procedure for inversion of the magnetic field that avoids use of the stream function. This approach provides enhanced accuracy of current reconstruction over a wide range of noise levels. We further introduce a reflection procedure that allows for the reconstruction of currents that cross the boundaries of the measurement window. The effectiveness of our approach is demonstrated by several numerical examples.

  13. A precision analogue integrator system for heavy current measurement in MFDC resistance spot welding

    International Nuclear Information System (INIS)

    Xia, Yu-Jun; Zhang, Zhong-Dian; Xia, Zhen-Xin; Zhu, Shi-Liang; Zhang, Rui

    2016-01-01

    In order to control and monitor the quality of middle frequency direct current (MFDC) resistance spot welding (RSW), precision measurement of the welding current up to 100 kA is required, for which Rogowski coils are the only viable current transducers at present. Thus, a highly accurate analogue integrator is the key to restoring the converted signals collected from the Rogowski coils. Previous studies emphasised that the integration drift is a major factor that influences the performance of analogue integrators, but capacitive leakage error also has a significant impact on the result, especially in long-time pulse integration. In this article, new methods of measuring and compensating capacitive leakage error are proposed to fabricate a precision analogue integrator system for MFDC RSW. A voltage holding test is carried out to measure the integration error caused by capacitive leakage, and an original integrator with a feedback adder is designed to compensate capacitive leakage error in real time. The experimental results and statistical analysis show that the new analogue integrator system could constrain both drift and capacitive leakage error, of which the effect is robust to different voltage levels of output signals. The total integration error is limited within  ±0.09 mV s −1 0.005% s −1 or full scale at a 95% confidence level, which makes it possible to achieve the precision measurement of the welding current of MFDC RSW with Rogowski coils of 0.1% accuracy class. (paper)

  14. Magnetically filtered Faraday probe for measuring the ion current density profile of a Hall thruster

    International Nuclear Information System (INIS)

    Rovey, Joshua L.; Walker, Mitchell L.R.; Gallimore, Alec D.; Peterson, Peter Y.

    2006-01-01

    The ability of a magnetically filtered Faraday probe (MFFP) to obtain the ion current density profile of a Hall thruster is investigated. The MFFP is designed to eliminate the collection of low-energy, charge-exchange (CEX) ions by using a variable magnetic field as an ion filter. In this study, a MFFP, Faraday probe with a reduced acceptance angle (BFP), and nude Faraday probe are used to measure the ion current density profile of a 5 kW Hall thruster operating over the range of 300-500 V and 5-10 mg/s. The probes are evaluated on a xenon propellant Hall thruster in the University of Michigan Large Vacuum Test Facility at operating pressures within the range of 4.4x10 -4 Pa Xe (3.3x10 -6 Torr Xe) to 1.1x10 -3 Pa Xe (8.4x10 -6 Torr Xe) in order to study the ability of the Faraday probe designs to filter out CEX ions. Detailed examination of the results shows that the nude probe measures a greater ion current density profile than both the MFFP and BFP over the range of angular positions investigated for each operating condition. The differences between the current density profiles obtained by each probe are attributed to the ion filtering systems employed. Analysis of the results shows that the MFFP, operating at a +5 A solenoid current, provides the best agreement with flight-test data and across operating pressures

  15. Neutron radiography characterization of an operating proton exchange membrane fuel cell with localized current distribution measurements

    International Nuclear Information System (INIS)

    Gagliardo, J.J.; Owejan, J.P.; Trabold, T.A.; Tighe, T.W.

    2009-01-01

    Neutron radiography has proven to be a powerful tool to study and understand the effects of liquid water in an operating fuel cell. In the present work, this experimental method is coupled with locally resolved current and ohmic resistance measurements, giving additional insight into water management and fuel cell performance under a variety of conditions. The effects of varying the inlet humidification level and the current density of the 50 cm 2 cell are studied by simultaneously monitoring electrochemical performance with a 10x10 matrix of current sensors, and liquid water volumes are measured using the National Institute of Standards and Technology (NIST) neutron imaging facility. A counter flow, straight channel proton exchange membrane (PEM) fuel cell is used to demonstrate localized performance loss corresponds to water-filled channels that impede gas transport to the catalyst layer, thereby creating an area that has low current density. Furthermore, certain operating conditions causing excess water accumulation in the channels can result in localized proton resistance increase, a result that can only be accurately observed with combined radiography and distributed electrochemical measurements.

  16. Current algebras, measures quasi-invariant under diffeomorphism groups, and infinite quantum systems with accumulation points

    Science.gov (United States)

    Sakuraba, Takao

    The approach to quantum physics via current algebra and unitary representations of the diffeomorphism group is established. This thesis studies possible infinite Bose gas systems using this approach. Systems of locally finite configurations and systems of configurations with accumulation points are considered, with the main emphasis on the latter. In Chapter 2, canonical quantization, quantization via current algebra and unitary representations of the diffeomorphism group are reviewed. In Chapter 3, a new definition of the space of configurations is proposed and an axiom for general configuration spaces is abstracted. Various subsets of the configuration space, including those specifying the number of points in a Borel set and those specifying the number of accumulation points in a Borel set are proved to be measurable using this axiom. In Chapter 4, known results on the space of locally finite configurations and Poisson measure are reviewed in the light of the approach developed in Chapter 3, including the approach to current algebra in the Poisson space by Albeverio, Kondratiev, and Rockner. Goldin and Moschella considered unitary representations of the group of diffeomorphisms of the line based on self-similar random processes, which may describe infinite quantum gas systems with clusters. In Chapter 5, the Goldin-Moschella theory is developed further. Their construction of measures quasi-invariant under diffeomorphisms is reviewed, and a rigorous proof of their conjectures is given. It is proved that their measures with distinct correlation parameters are mutually singular. A quasi-invariant measure constructed by Ismagilov on the space of configurations with accumulation points on the circle is proved to be singular with respect to the Goldin-Moschella measures. Finally a generalization of the Goldin-Moschella measures to the higher-dimensional case is studied, where the notion of covariance matrix and the notion of condition number play important roles. A

  17. Simultaneous rocket and radar measurements of currents in an auroral arc

    International Nuclear Information System (INIS)

    Robinson, R.M.; Bering, E.A.; Vondrak, R.R.; Anderson, H.R.; Cloutier, P.A.

    1981-01-01

    A detailed study of electric field, current and conductivities associated with an auroral arc was made in a coordinated rocket and radar experiment in Alaska on March 9, 1978. The payload, designated 29.007 UE, was launched at 1013 p.m. local time. It penetrated the diffuse aurora on the upleg and at apogee traversed field lines connected to a stable auroral arc of 40 kR intensity. Among the instruments carried by the payload were a vector magnetometer, a set of electrostatic double probes and a set of electron and proton spectrometers. Simultaneous electron density and line-of-sight velocity measurements were made by Chatanika radar operating in an elevation scan mode in the magnetic meridian plane. Both the radar and rocket measurements indicated that the zonal electric field was westward and approximately constant across the arc with a magnitude of about 7 mV/m. Small differences between the rocket and radar zonal electric field measurements indicated the presence of upward drifting ions in the region of the arc. The meridional field was large and northward equatorward of the arc, but negligible within the arc. Conductivities computed from measured fluxes of energetic electrons agreed well with the conductivities derived from the radar measureements of electron density. The electric field and conductivity measurements indicated that the zonal currents were eastward equatorward of the arc and westward within the arc. These electrojet currents agreed well with those inferred from the rocket magnetometer data. Better agreement was obtained when a westward neutral wind was added. The westward wind was also consistent with differences between the rocket and radar meridional electric fields. The meridional currents computed from the electric field measurements were northward over the entire region

  18. Study, design and manufacture eddy current probes for industry applications

    International Nuclear Information System (INIS)

    Nguyen Phuc; Nguyen Van Thuy; Vuong Binh Duong; Do Minh Duc; Trinh Dinh Truong; Tran Trong Duc; Do Tung Khanh; Dang Quang Trung

    2016-01-01

    This study is based on the studying, designing and manufacturing of eddy current probes for industry applications. The main tasks of this study include: i) Describes the overview and classification of eddy current probes (which can be classified into three categories based on the mode of operation: absolute eddy current probe, differential eddy current probe and reflect eddy current probe); ii) Describes the three methods of probe designing and manufacturing (including experimental, analytical and numerical designs); iii) Describes the designing and manufacturing of eddy current probes for industry applications, which based on experimental and analytical methods. Based on this study, we have successfully manufactured some current probes (including absolute eddy current probe, differential eddy current probe and reflect eddy current probe) for surface and tube inspections. (author)

  19. Measurement of current density fluctuations and ambipolar particle flux due to magnetic fluctuations in MST

    International Nuclear Information System (INIS)

    Shen, Weimin.

    1992-08-01

    Studies of magnetic fluctuation induced particle transport on Reversed Field Pinch plasmas were done on the Madison Symmetric Torus. Plasma current density and current density fluctuations were measured using a multi-coil magnetic probes. The low frequency (f parallel B r >. The result of zero net charged particle loss was obtained, meaning the flux is ambipolar. The ambipolarity of low frequency global tearing modes is satisfied through the phase relations determined by tearing instabilities. The ambipolarity of high frequency localized modes could be partially explained by the simple model of Waltz based on the radial average of small scale turbulence

  20. Nb/sub 3/Sn critical-current measurements using tubular fiberglass-epoxy mandrels

    International Nuclear Information System (INIS)

    Goodrich, L.F.; Bray, S.L.; Stauffer, T.C.

    1989-01-01

    A systematic study of the effect of sample mounting techniques on the superconducting critical-current measurement was made in conjunction with the VAMAS (Versailles Agreement on Advanced Materials and Standards) interlaboratory comparison (round robin) measurements. A seemingly small change in mandrel geometry can result in a 40% change in the measured critical current of a Nb/sub 3/Sn sample at 12 T. This is a result of a change in the conductor pre-strain at 4 K caused by variation in thermal contraction between thick- and thin-walled fiberglass-epoxy composite (G-10) tubes. An approximate measure of the variations in thermal contraction (from room to liquid nitrogen temperature) indicate a 0.2% greater contraction for the thick-walled tube. This difference, combined with strain sensitivity measurements, is consistent with the observed decrease in critical current. Previous publications on thermal contraction of G-10 have addressed the plate geometry, but not the tube geometry. The contraction of a G-10 plate is highly anisotropic. The radial contraction of a tube is different than the contraction of a plate, however, because the circumferential fiberglass is put into hoop compression by the epoxy, and the resulting contraction is a competition between the two structural components. This appears to be the source of the variation in thermal contraction with tube wall thickness

  1. Feasibility of ultrasonic and eddy current methods for measurement of residual stress in shot peened metals

    International Nuclear Information System (INIS)

    Lavrentyev, Anton I.; Stucky, Paul A.; Veronesi, William A.

    2000-01-01

    Shot peening is a well-known method for extending the fatigue life of metal components by introducing compressive residual stresses near their surfaces. The capability to nondestructively evaluate the near surface residual stress would greatly aid the assurance of proper fatigue life in shot-peened components. This paper presents preliminary results from a feasibility study examining the use of ultrasonic and eddy current NDE methods for residual stress measurement in components where the stress has been introduced by shot peening. With an ultrasonic method, a variation of ultrasonic surface wave speed with shot peening intensity was measured. Near surface conductivity was measured by eddy current methods. Since the effective penetration depth of both methods employed is inversely related to the excitation frequency, by making measurements at different frequencies, each method has the potential to provide the stress-depth profile. Experiments were conducted on aluminum specimens (alloy 7075-T7351) peened within the Almen peening intensity range of 4C to 16C. The experimental results obtained demonstrate a correlation between peening intensity and Rayleigh wave velocity and between peening intensity and conductivity. The data suggests either of the methods may be suitable, with limitations, for detecting unsatisfactory levels of shot peening. Several factors were found to contribute to the measured responses: surface roughness, near surface plastic deformation (cold work) and residual stress. The contribution of each factor was studied experimentally. The feasibility of residual stress determination from the measured data is discussed

  2. Development of an instrument for direct ozone production rate measurements: measurement reliability and current limitations

    Science.gov (United States)

    Sklaveniti, Sofia; Locoge, Nadine; Stevens, Philip S.; Wood, Ezra; Kundu, Shuvashish; Dusanter, Sébastien

    2018-02-01

    Ground-level ozone (O3) is an important pollutant that affects both global climate change and regional air quality, with the latter linked to detrimental effects on both human health and ecosystems. Ozone is not directly emitted in the atmosphere but is formed from chemical reactions involving volatile organic compounds (VOCs), nitrogen oxides (NOx = NO + NO2) and sunlight. The photochemical nature of ozone makes the implementation of reduction strategies challenging and a good understanding of its formation chemistry is fundamental in order to develop efficient strategies of ozone reduction from mitigation measures of primary VOCs and NOx emissions. An instrument for direct measurements of ozone production rates (OPRs) was developed and deployed in the field as part of the IRRONIC (Indiana Radical, Reactivity and Ozone Production Intercomparison) field campaign. The OPR instrument is based on the principle of the previously published MOPS instrument (Measurement of Ozone Production Sensor) but using a different sampling design made of quartz flow tubes and a different Ox (O3 and NO2) conversion-detection scheme composed of an O3-to-NO2 conversion unit and a cavity attenuated phase shift spectroscopy (CAPS) NO2 monitor. Tests performed in the laboratory and in the field, together with model simulations of the radical chemistry occurring inside the flow tubes, were used to assess (i) the reliability of the measurement principle and (ii) potential biases associated with OPR measurements. This publication reports the first field measurements made using this instrument to illustrate its performance. The results showed that a photo-enhanced loss of ozone inside the sampling flow tubes disturbs the measurements. This issue needs to be solved to be able to perform accurate ambient measurements of ozone production rates with the instrument described in this study. However, an attempt was made to investigate the OPR sensitivity to NOx by adding NO inside the instrument

  3. Beam-based measurements of persistent current decay in the Relativistic Heavy Ion Collider

    Directory of Open Access Journals (Sweden)

    W. Fischer

    2001-04-01

    Full Text Available The two rings of the Relativistic Heavy Ion Collider are equipped with superconducting dipole magnets. At injection, induced persistent currents in these magnets lead to a sextupole component. As the persistent currents decay with time, the horizontal and vertical chromaticities change. From magnet measurements of persistent current decays, chromaticity changes in the machine are estimated and compared with chromaticity measurements.

  4. Current-zero measurements of vacuum circuit breakers interrupting short-line faults

    NARCIS (Netherlands)

    Smeets, R.P.P.; Linden, van der W.A.

    2003-01-01

    Current zero measurements are performed during short-line fault interruption tests of vacuum circuit breakers. This switching cycle is characterized by a very steep transient recovery voltage. High-resolution measurements of near current-zero arc current and voltage were carried out. Various

  5. Lake Titicaca: History and current studies

    International Nuclear Information System (INIS)

    Paredes Riveros, M.A.; Gonfiantini, R.

    1999-01-01

    This article summarizes results of Titicaca lake water balance studies including the findings of the IAEA Technical Cooperation Project RLA/08/022. Direct precipitation over the lake accounts for about 55% of the water inflow and rivers and streams provide about 45% of the water inflow. Diffuse groundwater leakage into the lake from coastal aquifers is believed to represent a negligible term of water balance. Evaporation from the lake is strong and accounts for more than 95% of the water losses. The isotopic and chemical composition data obtained within the frameworks of the IAEA Technical Cooperation Project RLA/08/022 are discussed

  6. Lake Titicaca: History and current studies

    Energy Technology Data Exchange (ETDEWEB)

    Paredes Riveros, M A [PELT, Puno (Peru); Gonfiantini, R [Istituto di Geocronologia e Geochimica Isotopica del CNR, Pisa (Italy)

    1999-12-01

    This article summarizes results of Titicaca lake water balance studies including the findings of the IAEA Technical Cooperation Project RLA/08/022. Direct precipitation over the lake accounts for about 55% of the water inflow and rivers and streams provide about 45% of the water inflow. Diffuse groundwater leakage into the lake from coastal aquifers is believed to represent a negligible term of water balance. Evaporation from the lake is strong and accounts for more than 95% of the water losses. The isotopic and chemical composition data obtained within the frameworks of the IAEA Technical Cooperation Project RLA/08/022 are discussed.

  7. Advanced electrical current measurements of microdischarges: evidence of sub-critical pulses and ion currents in barrier discharge in air

    Science.gov (United States)

    Synek, Petr; Zemánek, Miroslav; Kudrle, Vít; Hoder, Tomáš

    2018-04-01

    Electrical current measurements in corona or barrier microdischarges are a challenge as they require both high temporal resolution and a large dynamic range of the current probe used. In this article, we apply a simple self-assembled current probe and compare it to commercial ones. An analysis in the time and frequency domain is carried out. Moreover, an improved methodology is presented, enabling both temporal resolution in sub-nanosecond times and current sensitivity in the order of tens of micro-amperes. Combining this methodology with a high-tech oscilloscope and self-developed software, a unique statistical analysis of currents in volume barrier discharge driven in atmospheric-pressure air is made for over 80 consecutive periods of a 15 kHz applied voltage. We reveal the presence of repetitive sub-critical current pulses and conclude that these can be identified with the discharging of surface charge microdomains. Moreover, extremely low, long-lasting microsecond currents were detected which are caused by ion flow, and are analysed in detail. The statistical behaviour presented gives deeper insight into the discharge physics of these usually undetectable current signals.

  8. Current Conceptual Challenges in the Study of Rhythm Processing Deficits

    Directory of Open Access Journals (Sweden)

    Pauline eTranchant

    2015-06-01

    Full Text Available Interest in the study of rhythm processing deficits (RPD is currently growing in the cognitive neuroscience community, as this type of investigation constitutes a powerful tool for the understanding of normal rhythm processing. Because this field is in its infancy, it still lacks a common conceptual vocabulary to facilitate effective communication between different researchers and research groups. In this commentary, we provide a brief review of recent reports of RPD through the lens of one important empirical issue: the method by which beat perception is measured, and the consequences of method selection for the researcher’s ability to specify which mechanisms are impaired in RPD. This critical reading advocates for the importance of matching measurement tools to the putative neurocognitive mechanisms under study, and reveals the need for effective and specific assessments of the different aspects of rhythm perception and synchronization.

  9. Chiral measurements with the Fixed-Point Dirac operator and construction of chiral currents

    International Nuclear Information System (INIS)

    Hasenfratz, P.; Hauswirth, S.; Holland, K.; Joerg, T.; Niedermayer, F.

    2002-01-01

    In this preliminary study, we examine the chiral properties of the parametrized Fixed-Point Dirac operator D FP , see how to improve its chirality via the Overlap construction, measure the renormalized quark condensate Σ-circumflex and the topological susceptibility χ t , and investigate local chirality of near zero modes of the Dirac operator. We also give a general construction of chiral currents and densities for chiral lattice actions

  10. Highly Sensitive Measurements of the Dark Current of Superconducting Cavities for TESLA Using a SQUID Based Cryogenic Current Comparator

    CERN Document Server

    Vodel, W; Nietzsche, S

    2004-01-01

    This contribution presents a Cryogenic Current Comparator (CCC) as an excellent tool for detecting dark currents generated, e.g. by superconducting cavities for the upcoming TESLA project (X-FEL) at DESY. To achieve the maximum possible energy the gradient of the superconducting RF cavities should be pushed close to the physical limit of 50 MV/m. The undesired field emission of electrons (so-called dark current) of the superconducting RF cavities at strong fields may limit the maximum gradient. The absolute measurement of the dark current in correlation with the gradient will give a proper value to compare and classify the cavities. The main component of the CCC is a highly sensitive LTS-DC SQUID system which is able to measure extremely low magnetic fields, e.g. caused by the dark current. For this reason the input coil of the SQUID is connected across a special designed toroidal niobium pick-up coil for the passing electron beam. A noise limited current resolution of nearly 2 pA/√(Hz) with a measu...

  11. Current status of studies on nodular corrosion

    International Nuclear Information System (INIS)

    Yasuda, Takayoshi; Kawasaki, Satoru; Echigoya, Hironori; Kinoshita, Yutaka; Kubota, Hiroyuki; Konishi, Takao; Yamanaka, Tuneyasu.

    1993-01-01

    The studies on nodular corrosion formed on the outer surface of BWR fuel cladding tubes were reviewed. Main factors affecting the corrosion behavior were material and environmental conditions and combined effect. The effects of such material conditions as fabrication process, alloy elements, texture and surface treatment and environmental factors as neutron irradiation, thermo-hydrodynamic, water chemistry, purity of the coolant and contact with foreign metals on the corrosion phenomena were surveyed. Out-of-reactor corrosion test methods and models for the corrosion mechanism were also reviewed. Suppression of the accumulated annealing temperature during tube reduction process improved the nodular corrosion resistance of Zircaloys. Improved resistance for the nodular corrosion was reported for the unirradiated Zircaloys with some additives. Detailed irradiation test under the BWR conditions is needed to confirm the trend. Concerning the environmental factors, boiling on the cladding surface due to heat flux reduces the nodular corrosion susceptibility, while oxidizing radical generated from dissolved oxygen accelerates the corrosion. Concerning corrosion mechanisms, importance of such phenomena as the depleted zone of alloying elements in zirconium matrix, reduction of H + to H 2 in oxide layer, electrochemical property of precipitates, crystallographic anisotropy of oxidation rates were revealed. (author) 59 refs

  12. Comparison of acoustic doppler current profiler and Price AA mechanical current meter measurements made during the 2011 Mississippi River Flood

    Science.gov (United States)

    O'Brien, Patrick; Mueller, David; Pratt, Thad

    2012-01-01

    The Mississippi River and Tributaries project performed as designed during the historic 2011 Mississippi River flood, with many of the operational decisions based on discharge targets as opposed to stage. Measurement of discharge at the Tarbert Landing, Mississippi range provides critical information used in operational decisions for the floodways located in Louisiana. Historically, discharge measurements have been made using a Price AA current meter and the mid-section method, and a long record exists based on these types of measurements, including historical peak discharges. Discharge measurements made using an acoustic Doppler current profiler from a moving boat have been incorporated into the record since the mid 1990's, and are used along with the Price AA mid-section measurements. During the 2011 flood event, both methods were used and appeared to provide different results at times. The apparent differences between the measurement techniques are due to complex hydrodynamics at this location that created large spatial and temporal fluctuations in the flow. The data and analysis presented herein show the difference between the two methods to be within the expected accuracy of the measurements when the measurements are made concurrently. The observed fluctuations prevent valid comparisons of data collected sequentially or even with different observation durations.

  13. Evaluation of uncertainties in femtoampere current measurement for the number concentration standard of aerosol nanoparticles

    International Nuclear Information System (INIS)

    Sakurai, Hiromu; Ehara, Kensei

    2011-01-01

    We evaluated uncertainties in current measurement by the electrometer at the current level on the order of femtoamperes. The electrometer was the one used in the Faraday-cup aerosol electrometer of the Japanese national standard for number concentration of aerosol nanoparticles in which the accuracy of the absolute current is not required, but the net current which is obtained as the difference in currents under two different conditions must be measured accurately. The evaluation was done experimentally at the current level of 20 fA, which was much smaller than the intervals between the electrometer's calibration points at +1, +0.5, −0.5 and −1 pA. The slope of the response curve for the relationship between the 'true' and measured current, which is crucial in the above measurement, was evaluated locally at many different points within the ±1 pA range for deviation from the slope determined by a linear regression of the calibration data. The sum of the current induced by a flow of charged particles and a bias current from a current-source instrument was measured by the electrometer while the particle current was toggled on and off. The net particle current was obtained as the difference in the measured currents between the toggling, while at the same time the current was estimated from the particle concentration read by a condensation particle counter. The local slope was calculated as the ratio of the measured to estimated currents at each bias current setting. The standard deviation of the local slope values observed at varied bias currents was about 0.003, which was calculated by analysis of variance (ANOVA) for the treatment of the bias current. The combined standard uncertainty of the slope, which was calculated from the uncertainty of the slope by linear regression and the variability of the slope, was calculated to be about 0.004

  14. Simulated wind-generated inertial oscillations compared to current measurements in the northern North Sea

    Science.gov (United States)

    Bruserud, Kjersti; Haver, Sverre; Myrhaug, Dag

    2018-04-01

    Measured current speed data show that episodes of wind-generated inertial oscillations dominate the current conditions in parts of the northern North Sea. In order to acquire current data of sufficient duration for robust estimation of joint metocean design conditions, such as wind, waves, and currents, a simple model for episodes of wind-generated inertial oscillations is adapted for the northern North Sea. The model is validated with and compared against measured current data at one location in the northern North Sea and found to reproduce the measured maximum current speed in each episode with considerable accuracy. The comparison is further improved when a small general background current is added to the simulated maximum current speeds. Extreme values of measured and simulated current speed are estimated and found to compare well. To assess the robustness of the model and the sensitivity of current conditions from location to location, the validated model is applied at three other locations in the northern North Sea. In general, the simulated maximum current speeds are smaller than the measured, suggesting that wind-generated inertial oscillations are not as prominent at these locations and that other current conditions may be governing. Further analysis of the simulated current speed and joint distribution of wind, waves, and currents for design of offshore structures will be presented in a separate paper.

  15. Oceanography of Wadge bank - current measurements over a tidal cycle off the south coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    RamaRaju, V.S.; RameshBabu, V.; Anto, A.F.

    Direct current measurements made during the onset and termination of SW monsoon indicate wide fluctuations in space and time. The nearshore current decreases in magnitude from the onset to the termination of the monsoon. The resultant surface...

  16. Simultaneous specimen current and time-dependent cathodoluminescence measurements on gallium nitride

    Energy Technology Data Exchange (ETDEWEB)

    Campo, E. M., E-mail: e.campo@bangor.ac.uk; Hopkins, L. [School of Electronic Engineering, Bangor University, Gwynedd LL57 1UT (United Kingdom); Pophristic, M. [Department of Chemistry and Biochemistry, University of the Science, Philadelphia, Pennsylvania 19104 (United States); Ferguson, I. T. [Department of Electrical and Computer Engineering, Missouri University of Science and Technology, Rolla, Missouri 65409 (United States)

    2016-06-28

    Time-dependent cathodoluminescence (CL) and specimen current (SC) are monitored to evaluate trapping behavior and evolution of charge storage. Examination of CL and SC suggests that the near band edge emission in GaN is reduced primarily by the activation of traps upon irradiation, and Gallium vacancies are prime candidates. At the steady state, measurement of the stored charge by empiric-analytical methods suggests that all available traps within the interaction volume have been filled, and that additional charge is being stored interstitially, necessarily beyond the interaction volume. Once established, the space charge region is responsible for the steady state CL emission and, prior to build up, it is responsible for the generation of diffusion currents. Since the non-recombination effects resulting from diffusion currents that develop early on are analogous to those leading to device failure upon aging, this study is fundamental toward a holistic insight into optical properties in GaN.

  17. Weak measurement from the electron displacement current: new path for applications

    International Nuclear Information System (INIS)

    Marian, D; Colomés, E; Oriols, X; Zanghì, N

    2015-01-01

    The interest on weak measurements is rapidly growing during the last years as a unique tool to better understand and predict new quantum phenomena. Up to now many theoretical and experimental weak-measurement techniques deal with (relativistic) photons or cold atoms, but there is much less investigation on (non-relativistic) electrons in up-to-date electronics technologies. We propose a way to perform weak measurements in nanoelectronic devices through the measurement of the total current (particle plus displacement component) in such devices. We study the interaction between an electron in the active region of a electron device with a metal surface working as a sensing electrode by means of the (Bohmian) conditional wave function. We perform numerical (Monte Carlo) simulations to reconstruct the Bohmian trajectories in the iconic double slit experiment. This work opens new paths for understanding the quantum properties of an electronic system as well as for exploring new quantum engineering applications in solid state physics. (paper)

  18. Diagnostic colonoscopy: performance measurement study.

    Science.gov (United States)

    Kuznets, Naomi

    2002-07-01

    This is the fifth of a series of best practices studies undertaken by the Performance Measurement Initiative (PMI), the centerpiece of the Institute for Quality Improvement (IQI), a not-for-profit quality improvement subsidiary of the Accreditation Association for Ambulatory Health Care (AAAHC) (Performance Measurement Initiative, 1999a, 1999b, 2000a, 2000b). The IQI was created to offer clinical performance measurement and improvement opportunities to ambulatory health care organizations and others interested in quality patient care. The purpose of the study was to provide opportunities to initiate clinical performance measurement on key processes and outcomes for this procedure and use this information for clinical quality improvement. This article provides performance measurement information on how organizations that have demonstrated and validated differences in clinical practice can have similar outcomes, but at a dramatically lower cost. The intent of the article is to provide organizations with alternatives in practice to provide a better value to their patients.

  19. Dynamic response of thermal neutron measurements in electrochemically produced cold fusion subject to pulsed current

    International Nuclear Information System (INIS)

    Granada, Jose; Converti, Jose; Mayer, Roberto; Guido, German; Florido, Pablo; Patino, Nestor; Sobehart, Leonardo; Gomez, Silvia; Larreteguy, Axel

    1988-01-01

    The present work shows the results of measurements performed on electrolytic cells using a high efficiency (22%) neutron detection system in combination with a procedure involving a non-stationary current through the cell's circuit. Cold fusion was produced in electrolytic cells containing LiH dissolved in heavy water with a palladium cathode. The dynamic response to low frequency current pulses was measured. Characteristic patterns showing one or two bumps were obtained in a repeatable fashion. These patterns are strongly dependent on the previous charging history of the cathode. The technique employed seems to be very convenient as a research tool for a systematic study of the different variables governing the phenomenon. (Author)

  20. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    Science.gov (United States)

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  1. Current situation and prospect of market on the latest radiation measuring instrument

    International Nuclear Information System (INIS)

    Ha, Chang Ho; Kim, Wang Geum; Cho, Gyu Seong

    2009-12-01

    This book deals with current situation and prospect of market on the latest radiation measuring instrument. The contents of this book are basic of technology on radiation measuring instrument with basic principle of various measuring instrument, current situation of technology and prospect of radiation measuring instrument, effect of spreading and application field of radiation measuring instrument, facility for making and research and development of radiation measuring instrument, prospect of market about radiation measuring instrument, strategy for market entry with the latest radiation measuring instrument and general prospect for the future.

  2. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Perevalov, Denis [Univ. of Alabama, Tuscaloosa, AL (United States)

    2009-12-01

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for vμ → ve neutrino oscillations at Δm2 ~ 1 eV2 using an intense neutrino flux with an average energy Ev ~ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0 x 1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semiinclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current π0, charged current quasi-elastic (CCQE), charged current π+, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (vN → vN) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Δs, this however requires a separation of NCE proton (vp → vp) from NCE neutron (vn → vn) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Δs measurement. In this thesis

  3. Neutrino-nucleus neutral current elastic interactions measurement in MiniBooNE

    Science.gov (United States)

    Perevalov, Denis

    The MiniBooNE experiment at the Fermi National Accelerator Laboratory (Fermilab) was designed to search for numu → nu e neutrino oscillations at Deltam 2 ˜ 1 eV2 using an intense neutrino flux with an average energy Enu ˜ 700 MeV. From 2002 to 2009 MiniBooNE has accumulated more than 1.0x1021 protons on target (POT) in both neutrino and antineutrino modes. MiniBooNE provides a perfect platform for detailed measurements of exclusive and semi-inclusive neutrino cross-sections, for which MiniBooNE has the largest samples of events up to date, such as neutral current elastic (NCE), neutral current pi 0, charged current quasi-elastic (CCQE), charged current pi +, and other channels. These measured cross-sections, in turn, allow to improve the knowledge of nucleon structure. This thesis is devoted to the study of NCE interactions. Neutrino-nucleus neutral current elastic scattering (nuN → nu N) accounts for about 18% of all neutrino interactions in MiniBooNE. Using a high-statistics, high purity sample of NCE interactions in MiniBooNE, the flux-averaged NCE differential cross-section has been measured and is being reported here. Further study of the NCE cross-section allowed for probing the structure of nuclei. The main interest in the NCE cross-section is that it may be sensitive to the strange quark contribution to the nucleon spin, Deltas, this however requires a separation of NCE proton (nup → nu p) from NCE neutron (nun → nun ) events, which in general is a challenging task. MiniBooNE uses a Cherenkov detector, which imposes restrictions on the measured nucleon kinematic variables, mainly due to the impossibility to reconstruct the nucleon direction below the Cherenkov threshold. However, at kinetic energies above this threshold MiniBooNE is able to identify NCE proton events that do not experience final state interactions (FSI). These events were used for the Deltas measurement. In this thesis MiniBooNE reports the NCE (n+p) cross-section, the measurement

  4. Field measurement on longshore current variation between Ratnagiri and Mangalore, west coast of India

    Digital Repository Service at National Institute of Oceanography (India)

    Chandramohan, P.; Nayak, B.U.; Anand, N.M.; SanilKumar, V.

    The daily measurements on longshore current velocity and direction were carried out at selected 12 stations along the coast between Ratnagiri and Mangalore, India. The directional wave data measured at Karwar were used to theoretically estimate...

  5. Vehicle charging and return current measurements during electron-beam emission experiments from the Shuttle Orbiter

    International Nuclear Information System (INIS)

    Hawkins, J.G.

    1988-01-01

    The prime objective of this research was to investigate the electro-dynamic response of the Shuttle Orbiter during electron beam emission from the payload bay. This investigation has been conducted by examining data collected by the Vehicle Charging And Potential (VCAP) Experiment. The VCAP experiment has flown on two Shuttle missions with a Fast Pulse Electron Generator (FPEG) capable of emitting a 100 mA beam of 1 keV electrons. Diagnostics of the charging and return current during beam emission were provided by a combined Charge and Current Probe (CCP) located in the payload bay of the Orbiter. The CCP measurements were used to conduct a parametric study of the vehicle charging and return current as a function of vehicle attitude, ambient plasma parameters, and emitted beam current. In particular, the CCP measurements were found to depend strongly on the ambient plasma density. The vehicle charging during a 100 mA beam emission was small when the predicted ambient plasma density was greater than 3 x 10 5 cm -3 , but appreciable charging occurred when the density was less than this value. These observations indicated that the effective current-collecting area of the Orbiter is approximately 42 m 2 , consistent with estimates for the effective area of the Orbiter's engine nozzles. The operation of the Orbiter's Reaction Control System thrusters can create perturbations in the Orbiter's neutral and plasma environment that affect the CCP measurements. The CCP signatures of thruster firings are quite complex, but in general they are consistent with the depletion of plasma density in the ram direction and the enhancement of plasma density in the Orbiter's wake

  6. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  7. Determination of current and rotational transform profiles in a current-carrying stellarator using soft x-ray emissivity measurements

    Science.gov (United States)

    Ma, X.; Cianciosa, M. R.; Ennis, D. A.; Hanson, J. D.; Hartwell, G. J.; Herfindal, J. L.; Howell, E. C.; Knowlton, S. F.; Maurer, D. A.; Traverso, P. J.

    2018-01-01

    Collimated soft X-ray (SXR) emissivity measurements from multi-channel cameras on the Compact Toroidal Hybrid (CTH) tokamak/torsatron device are incorporated in the 3D equilibrium reconstruction code V3FIT to reconstruct the shape of flux surfaces and infer the current distribution within the plasma. Equilibrium reconstructions of sawtoothing plasmas that use data from both SXR and external magnetic diagnostics show the central safety factor to be near unity under the assumption that SXR iso-emissivity contours lie on magnetic flux surfaces. The reconstruction results are consistent with those using the external magnetic data and a constraint on the location of q = 1 surfaces determined from the sawtooth inversion surface extracted from SXR brightness profiles. The agreement justifies the use of approximating SXR emission as a flux function in CTH, at least within the core of the plasma, subject to the spatial resolution of the SXR diagnostics. This improved reconstruction of the central current density indicates that the current profile peakedness decreases with increasing external transform and that the internal inductance is not a relevant measure of how peaked the current profile is in hybrid discharges.

  8. Experiences on current national income measures with reference to environmental and natural resources

    International Nuclear Information System (INIS)

    Franzese, R.; Gaudioso, D.

    1995-06-01

    The environment provides both a source of goods and services and a 'sink' for residues of the production and consumption processes. This is not reflected into conventional estimate of GDP (gross domestic product), the most commonly used measure of aggregate income. The purpose of this paper is to explore whether environmentally-adjusted national income measure can be derived. In the first part, the authors discuss both the shortcomings of the current national income measures, with reference to environmental and natural resources, and the debate on this issues; then they analyse the existing experiences to provide environmentally-adjusted indicators of national accounts. In the second part, the authors present an evaluation of the costs of environmental degradation in Italy in the period 1988-1990, based on the methodologies adopted in a pilot study carried out by UNSO (United Nations Statistical Office) and the World Bank for Mexico

  9. Quantitative estimation of defects from measurement obtained by remote field eddy current inspection

    International Nuclear Information System (INIS)

    Davoust, M.E.; Fleury, G.

    1999-01-01

    Remote field eddy current technique is used for dimensioning grooves that may occurs in ferromagnetic pipes. This paper proposes a method to estimate the depth and the length of corrosion grooves from measurement of a pick-up coil signal phase at different positions close to the defect. Grooves dimensioning needs the knowledge of the physical relation between measurements and defect dimensions. So, finite element calculations are performed to obtain a parametric algebraic function of the physical phenomena. By means of this model and a previously defined general approach, an estimate of groove size may be given. In this approach, algebraic function parameters and groove dimensions are linked through a polynomial function. In order to validate this estimation procedure, a statistical study has been performed. The approach is proved to be suitable for real measurements. (authors)

  10. Measurement and interpretation of current transmission in a crossed-field diode below cutoff

    International Nuclear Information System (INIS)

    Vanderberg, B.H.; Eninger, J.E.

    1997-01-01

    Measurements on the current-voltage-magnetic field characteristics of a space-charge-limited cylindrical cross-field diode below cutoff are presented. The measured current is found to be lower than predicted by simple cold-fluid theory. This reduction combined with observed oscillations in the current can be explained by secondary electron emission from the anode, leading to an increase of space charge in the diode. copyright 1997 American Institute of Physics

  11. Variability in measured current structure on the southwest continental shelf of India

    Digital Repository Service at National Institute of Oceanography (India)

    DineshKumar, P.K.; Srinivas, K.

    -1 Variability in Measured Current Structure on the Southwest Continental Shelf of India P.K. Dinesh Kumar and K. Srinivas National Institute of Oceanography, Regional Centre P.O.Box 1913, Cochin - 682018,India Email: dineshku@niokochi.org ABSTRACT... WORDS: Direct current measurements, tidal currents, southwest coast of India. INTRODUCTION The circulation pattern of the eastern Arabian Sea over the southwest continental shelf of India (inferred...

  12. Measurement of the absolute tunneling current density in field emission from tungsten(110)

    International Nuclear Information System (INIS)

    Ehrlich, C.D.; Plummer, E.W.

    1978-01-01

    The phenomenon of quantum-mechanical tunneling of an electron through a barrier in the potential energy has been well established in a variety of experiments. The quantity which is usually measured in these experiments is the rate of change of tunneling current and not the absolute current density. This paper reports on a direct measurement of the tunneling current density, which is found to be in good agreement with free-electron theory for W

  13. Induced electric currents in the Alaska oil pipeline measured by gradient, fluxgate, and SQUID magnetometers

    Science.gov (United States)

    Campbell, W. H.; Zimmerman, J. E.

    1979-01-01

    The field gradient method for observing the electric currents in the Alaska pipeline provided consistent values for both the fluxgate and SQUID method of observation. These currents were linearly related to the regularly measured electric and magnetic field changes. Determinations of pipeline current were consistent with values obtained by a direct connection, current shunt technique at a pipeline site about 9.6 km away. The gradient method has the distinct advantage of portability and buried- pipe capability. Field gradients due to the pipe magnetization, geological features, or ionospheric source currents do not seem to contribute a measurable error to such pipe current determination. The SQUID gradiometer is inherently sensitive enough to detect very small currents in a linear conductor at 10 meters, or conversely, to detect small currents of one amphere or more at relatively great distances. It is fairly straightforward to achieve imbalance less than one part in ten thousand, and with extreme care, one part in one million or better.

  14. Resource Assessment of Tidal Current Energy in Hangzhou Bay Based on Long Term Measurement

    Science.gov (United States)

    Zhang, Feng; Dai, Chun-Ni; Xu, Xue-Feng; Wang, Chuan-Kun; Ye, Qin

    2017-05-01

    Compared with other marine renewable energy, tidal current energy benefits a lot in high energy density and good predictability. Based on the measured tidal current data in Hangzhou Bay from Nov 2012 to Oct 2012, this paper analysed temporal and spatial changes of tidal current energy in the site. It is the first time measured data of such long time been taken in tidal current energy analysis. Occurrence frequency and duration of the current of different speed are given out in the paper. According to the analysis results, monthly average power density changed a lot in different month, and installation orientation of tidal current turbine significantly affected energy acquisition. Finally, the annual average power density of tidal current energy with coefficient Cp in the site was calculated, and final output of a tidal current plant was also estimated.

  15. Measurement and evaluation of EDM bearing currents by the normalized Joule integral

    International Nuclear Information System (INIS)

    Vidmar, Gregor; Miljavec, Damijan; Agrež, Dušan

    2014-01-01

    Apparent current density is the most common criterion used in literature to estimate bearing endangerment due to bearing currents. In the paper, a new criterion called the normalized Joule integral is proposed as a more reliable and accurate one. This approach is more general and gives good correlation between current in the bypass bridge and bearing current. Furthermore, it considers the whole current that causes bearing damage, not just its peak value. The choice of the normalized Joule integral is theoretically explained and supported by measurements and simulations. The levels of bearing endangerment related to the normalized Joule integral of bearing currents are estimated. (paper)

  16. Measurement of obesity prevention in childcare settings: A systematic review of current instruments.

    Science.gov (United States)

    Stanhope, Kaitlyn K; Kay, Christi; Stevenson, Beth; Gazmararian, Julie A

    The incidence of childhood obesity is highest among children entering kindergarten. Overweight and obesity in early childhood track through adulthood. Programs increasingly target children in early life for obesity prevention. However, the published literature lacks a review on tools available for measuring behaviour and environmental level change in child care. The objective is to describe measurement tools currently in use in evaluating obesity-prevention in preschool-aged children. Literature searches were conducted in PubMed using the keywords "early childhood obesity," "early childhood measurement," "early childhood nutrition" and "early childhood physical activity." Inclusion criteria included a discussion of: (1) obesity prevention, risk assessment or treatment in children ages 1-5 years; and (2) measurement of nutrition or physical activity. One hundred thirty-four publications were selected for analysis. Data on measurement tools, population and outcomes were abstracted into tables. Tables are divided by individual and environmental level measures and further divided into physical activity, diet and physical health outcomes. Recommendations are made for weighing advantages and disadvantages of tools. Despite rising numbers of interventions targeting obesity-prevention and treatment in preschool-aged children, there is no consensus for which tools represent a gold standard or threshold of accuracy. Copyright © 2016 Asia Oceania Association for the Study of Obesity. Published by Elsevier Ltd. All rights reserved.

  17. Current measurement in high-performance frequency converters; Strommessung in Hochleistungsumrichtern

    Energy Technology Data Exchange (ETDEWEB)

    Marien, Jan; Hetzler, Ullrich [Isabellenhuette Heusler GmbH und Co. KG, Dillenburg (Germany); Hornung, Hans-Georg; Zwinger, Stefan [Sensor-Technik Wiedemann GmbH, Kaufbeuren (Germany)

    2011-04-15

    The load cycles (raising, lowering, accelerating, braking) of cranes, lift trucks and other off-road vehicles are ideally suited for the efficient deployment of hybrid or full electrical drive technology. Current measurement is a key technology for advancing electrification. Sensor Technik Wiedemann places by her frequency converters on a shunt-based current measurement module from Isabellenhuette Heusler which permits highly accurate measurements. (orig.)

  18. Experimental evaluation of IGBT junction temperature measurement via peak gate current

    DEFF Research Database (Denmark)

    Baker, Nick; Munk-Nielsen, Stig; Iannuzzo, Francesco

    2015-01-01

    Temperature sensitive electrical parameters allow junction temperature measurements on power semiconductors without modification to module packaging. The peak gate current has recently been proposed for IGBT junction temperature measurement and relies on the temperature dependent resistance...... of the gate pad. Consequently, a consideration of chip geometry and location of the gate pad is required before interpreting temperature data from this method. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current....

  19. Measurements of Neutrino Charged Current Interactions at SciBooNE

    Energy Technology Data Exchange (ETDEWEB)

    Nakajima, Yasuhiro [Department of Physics, Kyoto University, Kyoto 606-8502 (Japan)], E-mail: nakajima@scphys.kyoto-u.ac.jp

    2009-08-15

    The SciBooNE experiment (FNAL-E954) is designed to measure neutrino-nucleous cross sections in the one GeV region. Additionally, SciBooNE serves as a near detector for MiniBooNE by measuring the neutrino flux. In this paper, we describe two analyses using neutrino charged current interactions at SciBooNE: a neutrino spectrum measurement and a search for charged current coherent pion production.

  20. Study of uranium plating measurement

    International Nuclear Information System (INIS)

    Lin Jufang; Wen Zhongwei; Wang Mei; Wang Dalun; Liu Rong; Jiang Li; Lu Xinxin

    2007-06-01

    In neutron physics experiments, the measurement for plate-thickness of uranium can directly affect uncertainties of experiment results. To measure the plate-thickness of transform target (enriched uranium plating and depleted uranium plating), the back to back ionization chamber, small solid angle device and Au-Si surface barrier semi-conductor, were used in the experiment study. Also, the uncertainties in the experiment were analyzed. Because the inhomo-geneous of uranium lay of plate can quantitively affect the result, the homogeneity of uranium lay is checked, the experiment result reflects the homogeneity of uranium lay is good. (authors)

  1. Thermal neutron measurements on electrolytic cells with deuterated palladium cathodes subjected to a pulsed current

    International Nuclear Information System (INIS)

    Granada, J.R.; Mayer, R.E.; Guido, G.; Florido, P.C.; Larreteguy, A.; Gillette, V.H.; Patino, N.E.; Converti, J.; Gomez, S.E.

    1990-01-01

    The present work describes the design of a high efficiency thermal neutron detection system and the measurements performed with it on electrolytic cells containing LiH dissolved in D 2 O with palladium cathodes. A procedure involving the use of a non-stationary (pulsed) current through the cell caused a correlated neutron production to be observed in a repeatable manner. These patterns are strongly dependent on the previous charging history of the cathodes. The technique employed seems to be very useful as a research tool for a systematic study of the different variables governing the phenomenon. (author)

  2. Classification of methods for measuring current-voltage characteristics of semiconductor devices

    Directory of Open Access Journals (Sweden)

    Iermolenko Ia. O.

    2014-06-01

    Full Text Available It is shown that computer systems for measuring current-voltage characteristics are very important for semiconductor devices production. The main criteria of efficiency of such systems are defined. It is shown that efficiency of such systems significantly depends on the methods for measuring current-voltage characteristics of semiconductor devices. The aim of this work is to analyze existing methods for measuring current-voltage characteristics of semiconductor devices and to create the classification of these methods in order to specify the most effective solutions in terms of defined criteria. To achieve this aim, the most common classifications of methods for measuring current-voltage characteristics of semiconductor devices and their main disadvantages are considered. Automated and manual, continuous, pulse, mixed, isothermal and isodynamic methods for measuring current-voltage characteristics are analyzed. As a result of the analysis and generalization of existing methods the next classification criteria are defined: the level of automation, the form of measurement signals, the condition of semiconductor device during the measurements, and the use of mathematical processing of the measurement results. With the use of these criteria the classification scheme of methods for measuring current-voltage characteristics of semiconductor devices is composed and the most effective methods are specified.

  3. Measurement of the ratios of neutral-current to charged current cross sections of neutrino and antineutrino interactions in Ne

    Science.gov (United States)

    Bosetti, P. C.; Fritze, P.; Grässler, H.; Hasert, F. J.; Schulte, R.; Schultze, K.; Geich-Gimbel, C.; Nellen, B.; Pech, R.; Wünsch, B.; Grant, A.; Hulth, P. O.; Klein, H.; Morrison, D. R. O.; Pape, L.; Wachsmuth, H.; Vayaki, A.; Barnham, K. W. J.; Beuselinck, R.; Clayton, E. F.; Miller, D. B.; Mobayyen, M. M.; Petrides, A.; Albajar, C.; Myatt, G.; Saitta, B.; Wells, J.; Bolognese, T.; Vignaud, D.; Aachen-Bonn-CERN-Democritos-Imperial College, London-Oxford-Saclay Collaboration

    1983-05-01

    The ratios of neutral current to charged current cross sections of neutrino and antineutrino interactions in heavy Ne/H 2 mixture have been measured in BEBC. The beam was the CERN SPS 200 GeV/ c narrow band beam. The ratios were obtained using a cut in the transverse momentum of the hadronic system. In the standard Glashow-Salam-Weinberg model, our results correspond to the value of sin 2θw = 0.182 ± 0.020 ± 0.012. By combining this experiment with data from a hydrogen target the coupling constants uL2 and L2 are found to be 0.15 ± 0.04 and 0.19 ± 0.05, respectively.

  4. Measurement of the ratios of neutral-current to charged current cross sections of neutrino and antineutrino interactions in Ne

    International Nuclear Information System (INIS)

    Bosetti, P.C.; Fritze, P.; Graessler, H.; Hasert, F.J.; Schulte, R.; Schultze, K.; Vayaki, A.; Barnham, K.W.J.; Beuselinck, R.; Clayton, E.F.; Miller, D.B.; Mobayyen, M.M.; Petrides, A.; Albajar, C.; Myatt, G.; Saitta, B.; Wells, J.

    1983-01-01

    The ratios of neutral current to charged current cross sections of neutrino and antineutrino interactions in heavy Ne/H 2 mixture have been measured in BEBC. The beam was the CERN SPS 200 GeV/c narrow band beam. The ratios were obtained using a cut in the transverse momentum of the hadronic system. In the standard Glashow-Salam-Weinberg model, our results correspond to the value of sin 2 THETAsub(w)=0.182+-0.020+-0.012. By combining this experiment with data from a hydrogen target the coupling constants usub(L) 2 and dsub(L) 2 are found to be 0.15+-0.04 and 0.19+-0.05, respectively. (orig.)

  5. On Leakage Current Measured at High Cell Voltages in Lithium-Ion Batteries

    Energy Technology Data Exchange (ETDEWEB)

    Vadivel, Nicole R.; Ha, Seungbum; He, Meinan; Dees, Dennis; Trask, Steve; Polzin, Bryant; Gallagher, Kevin G.

    2017-01-01

    In this study, parasitic side reactions in lithium-ion batteries were examined experimentally using a potentiostatic hold at high cell voltage. The experimental leakage current measured during the potentiostatic hold was compared to the Tafel expression and showed poor agreement with the expected transfer coefficient values, indicating that a more complicated expression could be needed to accurately capture the physics of this side reaction. Here we show that cross-talk between the electrodes is the primary contribution to the observed leakage current after the relaxation of concentration gradients has ceased. This cross-talk was confirmed with experiments using a lithium-ion conducting glass ceramic (LICGC) separator, which has high conductance only for lithium cations. The cells with LICGC separators showed significantly less leakage current during the potentiostatic hold test compared to cells with standard microporous separators where cross-talk is present. In addition, direct-current pulse power tests show an impedance rise for cells held at high potentials and for cells held at high temperatures, which could be attributed to film formation from the parasitic side reaction. Based on the experimental findings, a phenomenological mechanism is proposed for the parasitic side reaction which accounts for cross-talk and mass transport of the decomposition products across the separator.

  6. An Intrinsic Fiber-Optic Sensor for Structure Lightning Current Measurement

    Science.gov (United States)

    Nguyen, Truong X.; Ely, Jay J.; Szatkowski, George N.; Mata, Carlos T.; Mata, Angel. G.; Snyder, Gary P.

    2014-01-01

    An intrinsic optical-fiber sensor based on Faraday Effect is developed that is highly suitable for measuring lightning current on aircraft, towers and complex structures. Originally developed specifically for aircraft installations, it is light-weight, non-conducting, structure conforming, and is immune to electromagnetic interference, hysteresis and saturation. It can measure total current down to DC. When used on lightning towers, the sensor can help validate other sensors and lightning detection network measurements. Faraday Effect causes light polarization to rotate when the fiber is exposed to a magnetic field in the direction of light propagation. Thus, the magnetic field strength can be determined from the light polarization change. By forming closed fiber loops and applying Ampere's law, measuring the total light rotation yields the total current enclosed. A broadband, dual-detector, reflective polarimetric scheme allows measurement of both DC component and AC waveforms with a 60 dB dynamic range. Two systems were built that are similar in design but with slightly different sensitivities. The 1310nm laser system can measure 300 A - 300 kA, and has a 15m long sensing fiber. It was used in laboratory testing, including measuring current on an aluminum structure simulating an aircraft fuselage or a lightning tower. High current capabilities were demonstrated up to 200 kA at a lightning test facility. The 1550nm laser system can measure 400 A - 400 kA and has a 25m fiber length. Used in field measurements, excellent results were achieved in the summer of 2012 measuring rocket-triggered lightning at the International Center for Lightning Research and Testing (ICLRT), Camp Blanding, Florida. In both systems increased sensitivity can be achieved with multiple fiber loops. The fiber optic sensor provides many unique capabilities not currently possible with traditional sensors. It represents an important new tool for lightning current measurement where low weight

  7. Measurements of picosecond pulses of a high-current electron accelerator

    International Nuclear Information System (INIS)

    Zheltov, K.A.; Petrenko, A.N.; Turundaevskaya, I.G.; Shalimanov, V.F.

    1997-01-01

    The duration of a picosecond high-current accelerator electron beam pulse duration is measured and its shape is determined using a measuring line, comprising a Faraday cup, a radiofrequency cable of minor length and a wide-band SRG-7 oscillograph. The procedure of data reconstruction according to regularization method is applied to determine the actual shape of the pulse measured

  8. The adequacy of measures of gender roles attitudes: a review of current measures in omnibus surveys.

    Science.gov (United States)

    Walter, Jessica Gabriele

    2018-01-01

    The measures of attitudes toward gender roles included in many representative international and national omnibus surveys were developed mostly in the 1970s and 1980s with a focus on the male breadwinner model. This article deals with the issue of whether the measures provided in these omnibus surveys need to be adjusted to specific social changes. A review of these measures has found that adjustments have occurred in a limited way that focused on the role of women and disregarded the role of men. Furthermore, most of these measures only examined the traditional roles of men and women. More egalitarian role models have not been considered sufficiently. In addition, most items that have been measured are phrased in a general form and, for example, do not specify parents' employment or the ages of children. A specification of these aspects of measurement would help to clarify the conceptual meaning of the results and increase the possibility of more accurately analyzing gender role attitudes over time.

  9. Comparative study on current trading system and online trading: the ...

    African Journals Online (AJOL)

    Comparative study on current trading system and online trading: the case of ... of online trading and factors affecting its feasibility of implementation in ECX. ... The study found that there is significant capacity problem with major skills gap with ...

  10. Vessel Eddy Current Measurement for the National Spherical Torus Experiment (NSTX)

    International Nuclear Information System (INIS)

    Gates, D.A.; Menard, J.; Marsala, R.

    2004-01-01

    A simple analog circuit that measures the NSTX axisymmetric eddy current distribution has been designed and constructed. It is based on simple circuit model of the NSTX vacuum vessel that was calibrated using a special axisymmetric eddy current code which was written so that accuracy was maintained in the vicinity of the current filaments. The measurement and the model have been benchmarked against data from numerous vacuum shots and they are in excellent agreement. This is an important measurement that helps give more accurate equilibrium reconstructions

  11. Measurement of weak magnetic field of corrosion current of isolated corrosion center

    Directory of Open Access Journals (Sweden)

    I. V. Bardin

    2015-01-01

    Full Text Available A very small magnetic field of corrosion current, of the order of 10−4 Oe, generated by isolated zinc inclusion in a copper platelet placed in electrolyte has been measured for the first time with a highly sensitive giant magneto-impedance magnetometer. The total corrosion current of the inclusion is estimated comparing the measured magnetic field distribution with corresponding theoretical calculation. The estimated value of the total corrosion current turns out to be in reasonable agreement with that one obtained in the standard gravimetric measurement.

  12. Kiloampere, Variable-Temperature, Critical-Current Measurements of High-Field Superconductors.

    Science.gov (United States)

    Goodrich, L F; Cheggour, N; Stauffer, T C; Filla, B J; Lu, X F

    2013-01-01

    K to those measured on the same specimen in flowing helium gas ("gas" or I c gas) at the same temperature. These comparisons indicate the temperature control is effective over the superconducting wire length between the voltage taps, and this condition is valid for all types of sample investigated, including Nb-Ti, Nb3Sn, and MgB2 wires. The liquid/gas comparisons are used to study the variable-temperature measurement protocol that was necessary to obtain the "correct" critical current, which was assumed to be the I c liq. We also calibrated the magnetoresistance effect of resistive thermometers for temperatures from 4 K to 35 K and magnetic fields from 0 T to 16 T. This calibration reduces systematic errors in the variable-temperature data, but it does not affect the liquid/gas comparison since the same thermometers are used in both cases.

  13. Studies on fast wave current drive in the JAERI tokamaks

    International Nuclear Information System (INIS)

    Kimura, H.; Yamamoto, T.; Fujii, T.; Kawashima, H.; Tamai, H.; Saigusa, M.; Imai, T.; Hamamatsu, K.; Fukuyama, A.

    1991-01-01

    Fast wave electron heating experiment (FWEH) on JFT-2M and JT-60 and analysis of fast wave current drive (FWCD) ability on JT-60U are presented. In the JFT-2M, absorption of fast waves have been investigated by using a phased four-loop antenna array. The absorption of the fast waves has been studied for various plasma parameters by using combination of other additional heating methods such as electron cyclotron heating (ECH) and ion cyclotron heating. It is shown that the absorption efficiency estimated from various methods well correlates with one calculated theoretically in single pass damping. Interaction of the fast waves with fast electrons in combination with ECH has been examined through the measurement of non-thermal electron cyclotron emission (ECE). The observed ECE during FWEH is well explained by the theoretical model, which indicates generation of the appreciable energetic fast electrons by the fast waves. New four-loop array antennas have been employed to improve the absorption of unidirectionally-propagating waves. Characteristics of antenna loading resistance can be reproduced by a coupling calculation code. In JT-60, FWEH experiment in combination with lower hybrid current drive was performed. Power absorption efficiency of fast wave is substantially improved in combination with LHCD of relatively low power for both phasing modes. Bulk electron heating is observed with high-k // mode and coupling with fast electron is confirmed in hard X-ray emission with low-k // mode. The results are consistent with theoretical prediction based on 1.D full wave code. Synergetic effects between FWEH and LHCD are found. Coupling calculation indicates that eight-loop antenna is favourable for keeping high directivity in the required N // -range. Current drive efficiency is calculated with 1-D full wave code including trapped particle effects and higher harmonic ion cyclotron damping

  14. Measurement of azimuthal asymmetries in neutral current deep inelastic scattering at HERA

    Energy Technology Data Exchange (ETDEWEB)

    Chekanov, S.; Derrick, M.; Magill, S. [Argonne National Laboratory, Argonne, IL (US)] (and others)

    2006-08-15

    The distribution of the azimuthal angle of charged and neutral hadrons relative to the lepton plane has been studied for neutral current deep inelastic ep scattering using an integrated luminosity of 45 pb{sup -1} taken with the ZEUS detector at HERA. The measurements were made in the hadronic centre-of-mass system. The analysis exploits the energy-flow method, which allows the measurement to be made over a larger range of pseudorapidity compared to previous results. The dependence of the moments of the azimuthal distributions on the pseudorapidity and minimum transverse energy of the final-state hadrons are presented. Although the predictions from next-to-leading-order QCD describe the data better than do the Monte Carlo models incorporating leading-logarithm parton showers, they still fail to describe the magnitude of the asymmetries. This suggests that higher-order calculations may be necessary to describe these data. (Orig.)

  15. Measurement of azimuthal asymmetries in neutral current deep inelastic scattering at HERA

    International Nuclear Information System (INIS)

    Chekanov, S.; Derrick, M.; Magill, S.

    2006-08-01

    The distribution of the azimuthal angle of charged and neutral hadrons relative to the lepton plane has been studied for neutral current deep inelastic ep scattering using an integrated luminosity of 45 pb -1 taken with the ZEUS detector at HERA. The measurements were made in the hadronic centre-of-mass system. The analysis exploits the energy-flow method, which allows the measurement to be made over a larger range of pseudorapidity compared to previous results. The dependence of the moments of the azimuthal distributions on the pseudorapidity and minimum transverse energy of the final-state hadrons are presented. Although the predictions from next-to-leading-order QCD describe the data better than do the Monte Carlo models incorporating leading-logarithm parton showers, they still fail to describe the magnitude of the asymmetries. This suggests that higher-order calculations may be necessary to describe these data. (Orig.)

  16. A Method for Eddy Current Field Measurement in Permanent Magnet Magnetic Resonance Imaging Systems

    Directory of Open Access Journals (Sweden)

    SONG Rui

    2018-03-01

    Full Text Available Magnetic resonance imaging (MRI is a widely used medical imaging technique. In MRI system, gradient magnetic fields are used to code spatial information. However, the fast-switching electric currents in the gradients coils used to generate gradient fields also induce vortex electric field, often referred as eddy current, in the surrounding metal conductors. In this paper, a method for eddy current field measurement was proposed. Based on the Faraday law of electromagnetic induction, an eddy current field measuring device was designed. Combining hardware acquisition and software processing, the eddy current field was obtained by subtracting the ideal gradient field from the magnetic field measured experimentally, whose waveform could be displayed in real time. The proposed method was verified by experimental results.

  17. Sunlight effects on the 3D polar current system determined from low Earth orbit measurements

    DEFF Research Database (Denmark)

    Laundal, Karl M.; Finlay, Chris; Olsen, Nils

    2016-01-01

    Interaction between the solar wind and the Earth’s magnetosphere is associated with large-scale currents in the ionosphere at polar latitudes that flow along magnetic field lines (Birkeland currents) and horizontally. These current systems are tightly linked, but their global behaviors are rarely...... analyzed together. In this paper, we present estimates of the average global Birkeland currents and horizontal ionospheric currents from the same set of magnetic field measurements. The magnetic field measurements, from the low Earth orbiting Swarm and CHAMP satellites, are used to co-estimate poloidal...... and toroidal parts of the magnetic disturbance field, represented in magnetic apex coordinates. The use of apex coordinates reduces effects of longitudinal and hemispheric variations in the Earth’s main field. We present global currents from both hemispheres during different sunlight conditions. The results...

  18. A study of inclusive charged current neutrino interactions in deuterium

    International Nuclear Information System (INIS)

    Visser, C.P.

    1986-01-01

    In this thesis the results of an analysis of inclusive neutrino and antineutrino interaction on deuterium nuclei are presented. The use of deuterium as a target provides a mean to study proton and neutron scattering separately. The presently accepted theory of electro-weak interactions is reviewed. Applications of the quark-parton model in the context of deep-inelastic neutrino interactions on nucleons are summarized. The concept of scaling and its consequences are treated, together with some sources of violation of scaling. The properties of the CERN wide-band neutrino beam and an overview of the elements of this beam are given. The method to determine the energy distribution and the composition of the neutrino and antineutrino beam is described. The technique employed to separate neutrino interactions on protons and neutrons is discussed. Results of the measurement of the total nucleon charged-current cross-sections and differential cross-sections are presented. The relative contributions of quarks and antiquarks to the neutrino cross-sections are deduced from y-distributions and compared to those obtained from the total cross-section measurements. Finally, the analysis of the structure functions is given. (Auth.)

  19. WISM - A Wideband Instrument for Snow Measurement: Past Accomplishments, Current Status, and Path Forward

    Science.gov (United States)

    Bonds, Quenton; Racette, Paul; Durham, Tim (Principal Investigator)

    2016-01-01

    Presented are the prior accomplishments, current status and path forward for GSFC's Wideband Instrument for Snow Measurement (WISM). This work is a high level overview of the project, presented via Webinar to the IEEE young professionals.

  20. Electronic system for the automation of current measurements produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco; Dias, Mauro da Silva

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology in the determination of radionuclide activity. For this purpose measurements of very low ionization currents, in the range of 10 -8 to 10 -14 A, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. In the present work, an automation system, developed for current integration measurements at the Laboratorio de Metrologia Nuclear (LMN) of Instituto de Pesquisas Energeticas e Nucleares (IPEN), is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card CAD12/32 (LYNX Tecnologia Eletronica Ltda.). Measurements, using an electrometer Keithley 616 (Keithley Instruments, Inc) and an ionization chamber IG12/A20 (20 th Century Electronics Ltd.), were performed in order to check the system and for validating the project. (author)

  1. First Measurement of Charged Current Cross Sections at HERA with Longitudinally Polarised Positrons

    CERN Document Server

    Aktas, A.; Anthonis, T.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Babaev, A.; Backovic, S.; Bahr, J.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Baudrand, S.; Baumgartner, S.; Becker, J.; Beckingham, M.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, Ch.; Berger, N.; Bizot, J.C.; Boenig, M.-O.; Boudry, V.; Bracinik, J.; Brandt, G.; Brisson, V.; Bruncko, D.; Busser, F.W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Contreras, J.G.; Coughlan, J.A.; Cox, B.E.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Dau, W.D.; Daum, K.; de Boer, Y.; Delcourt, B.; Del Degan, M.; De Roeck, A.; Desch, K.; De Wolf, E.A.; Diaconu, C.; Dodonov, V.; Dubak, A.; Eckerlin, Guenter; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Elsen, E.; Erdmann, W.; Essenov, S.; Falkewicz, A.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Fleischmann, P.; Flucke, G.; Fomenko, A.; Foresti, I.; Franke, G.; Frisson, T.; Gabathuler, E.; Garutti, E.; Gayler, J.; Gerlich, C.; Ghazaryan, Samvel; Ginzburgskaya, S.; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gorbounov, S.; Goyon, C.; Grab, C.; Greenshaw, T.; Gregori, M.; Grell, B.R.; Grindhammer, Guenter; Gwilliam, C.; Haidt, D.; Hajduk, L.; Hansson, M.; Heinzelmann, G.; Henderson, R.C.W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K.H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Hussain, S.; Ibbotson, M.; Ismail, M.; Jacquet, M.; Janauschek, L.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, D.P.; Jung, Andreas Werner; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I.R.; Kiesling, Christian M.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knies, G.; Knutsson, A.; Korbel, V.; Kostka, P.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Kruger, K.; Kuckens, J.; Landon, M.P.J.; Lange, W.; Lastovicka, T.; Lastovicka-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Lindfeld, L.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Lobodzinska, E.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.-I.; Lueders, H.; Luke, D.; Lux, T.; Lytkin, L.; Makankine, A.; Malden, N.; Malinovski, E.; Mangano, S.; Marage, P.; Marshall, R.; Martisikova, M.; Martyn, H.-U.; Maxfield, S.J.; Meer, D.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Milstead, D.; Mladenov, D.; Mohamed, A.; Moreau, F.; Morozov, A.; Morris, J.V.; Mozer, Matthias Ulrich; Muller, K.; Murin, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, Paul R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nozicka, M.; Oganezov, R.; Olivier, B.; Olsson, J.E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Papadopoulou, T.; Pascaud, C.; Patel, G.D.; Peng, H.; Perez, E.; Perez-Astudillo, D.; Perieanu, A.; Petrukhin, A.; Pitzl, D.; Placakyte, R.; Portheault, B.; Povh, B.; Prideaux, P.; Rahmat, A.J.; Raicevic, N.; Reisert, B.; Reimer, P.; Rimmer, A.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Salvaire, F.; Sankey, D.P.C.; Sauvan, E.; Schatzel, S.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schoning, A.; Schultz-Coulon, H.-C.; Sedlak, K.; Sefkow, F.; Shaw-West, R.N.; Sheviakov, I.; Shtarkov, L.N.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, Arnd E.; Steder, M.; Stella, B.; Stiewe, J.; Strauch, I.; Straumann, U.; Sunar, D.; Tchoulakov, V.; Thompson, Graham; Thompson, P.D.; Tomasz, F.; Traynor, D.; Truoel, Peter; Tsakov, I.; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Usik, A.; Utkin, D.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Veelken, C.; Vinokurova, S.; Volchinski, V.; Wacker, K.; Wagner, J.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Wessels, M.; Wessling, B.; Wigmore, C.; Wissing, Ch.; Wolf, R.; Wunsch, E.; Xella, S.; Yan, W.; Yeganov, V.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y.C.; Zimmermann, J.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2006-01-01

    Data taken with positrons of different longitudinal polarisation states in collision with unpolarised protons at HERA are used to measure the total cross sections of the charged current process, e^+ p \\to \\bar{\

  2. Terrestrial ring current - from in situ measurements to global images using energetic neutral atoms

    International Nuclear Information System (INIS)

    Roelof, E.C.; Williams, D.J.

    1988-01-01

    Electrical currents flowing in the equatorial magnetosphere, first inferred from ground-based magnetic disturbances, are carried by trapped energetic ions. Spacecraft measurements have determined the spectrum and composition of those currents, and the newly developed technique of energetic-neutral-atom imaging allows the global dynamics of that entire ion population to be viewed from a single spacecraft. 71 references

  3. Measurement of the neutral-current interactions of high-energy neutrinos and antineutrinos

    International Nuclear Information System (INIS)

    Wanderer, P.; Benvenuti, A.; Cline, D.; Imlay, R.; Reeder, D.D.; Stefanski, R.; Rubbia, C.; Sulak, L.; Messing, F.; Ford, W.T.; Ling, T.Y.; Mann, A.K.

    1978-01-01

    Measurements of the ν and nu-bar weak hadronic neutral-current total cross sections and hadron energy distributions are consistent with a V - A form for this current. They are three standard deviations from pure V, pure A, or a pure T form and unambiguously exclude V + A and any linear combination of S and P

  4. Research of Measurement Circuits for High Voltage Current Transformer Based on Rogowski Coils

    Directory of Open Access Journals (Sweden)

    Yan Bing

    2014-02-01

    Full Text Available The electronic current transformer plays an irreplaceable position in the field of relay protection and current measurement of the power system. Rogowski coils are used as sensor parts, and in order to improve the measurement accuracy and reliability, the circuits at the high voltage system are introduced and improved in this paper, including the analog integral element, the filtering circuit and the phase shift circuit. Simulations results proved the reliability and accuracy of the improved circuits.

  5. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    OpenAIRE

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma def...

  6. Use of Direct Current Resistivity Measurements to Assess AISI 304 Austenitic Stainless Steel Sensitization

    OpenAIRE

    Mesquita, Ramaiany Carneiro; Mecury, José Manoel Rivas; Tanaka, Auro Atsumi; Sousa, Regina Célia de

    2015-01-01

    This paper describes the feasibility of using direct current electrical resistivity measurements to evaluate AISI 304 austenitic stainless steel sensitization. ASTM A262 – Practice A and double loop electrochemical potentiodynamic reactivation (DL-EPR) tests were performed to assess the degree of sensitization (DoS) qualitatively and quantitatively, and electrical resistivity (ER) was measured by the four-point direct-current potential drop method. The results indicate that the DoS incr...

  7. Method of measuring the current density distribution and emittance of pulsed electron beams

    International Nuclear Information System (INIS)

    Schilling, H.B.

    1979-07-01

    This method of current density measurement employs an array of many Faraday cups, each cup being terminated by an integrating capacitor. The voltages of the capacitors are subsequently displayed on a scope, thus giving the complete current density distribution with one shot. In the case of emittance measurements, a moveable small-diameter aperture is inserted at some distance in front of the cup array. Typical results with a two-cathode, two-energy electron source are presented. (orig.)

  8. MEASURING RESULTS NUMERAL TREATMENT OF IMPULSIVE CURRENTS BY MEANS OF ROGOVSKY BELT APPLICATION

    Directory of Open Access Journals (Sweden)

    U. Batygin

    2009-01-01

    Full Text Available The technique of numerical processing of measurement results of pulse currents by means of Rogovsky belt application is offered in the given work. It is shown that at measurement of signals by digital oscillographs and further numerical transformation of target signals, the possibilities of Rogovsky belt without the application of additional devices that in turn allows to define parameters of pulse currents with any peak-time characteristics essentially expand.

  9. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  10. Circular Array of Magnetic Sensors for Current Measurement: Analysis for Error Caused by Position of Conductor.

    Science.gov (United States)

    Yu, Hao; Qian, Zheng; Liu, Huayi; Qu, Jiaqi

    2018-02-14

    This paper analyzes the measurement error, caused by the position of the current-carrying conductor, of a circular array of magnetic sensors for current measurement. The circular array of magnetic sensors is an effective approach for AC or DC non-contact measurement, as it is low-cost, light-weight, has a large linear range, wide bandwidth, and low noise. Especially, it has been claimed that such structure has excellent reduction ability for errors caused by the position of the current-carrying conductor, crosstalk current interference, shape of the conduction cross-section, and the Earth's magnetic field. However, the positions of the current-carrying conductor-including un-centeredness and un-perpendicularity-have not been analyzed in detail until now. In this paper, for the purpose of having minimum measurement error, a theoretical analysis has been proposed based on vector inner and exterior product. In the presented mathematical model of relative error, the un-center offset distance, the un-perpendicular angle, the radius of the circle, and the number of magnetic sensors are expressed in one equation. The comparison of the relative error caused by the position of the current-carrying conductor between four and eight sensors is conducted. Tunnel magnetoresistance (TMR) sensors are used in the experimental prototype to verify the mathematical model. The analysis results can be the reference to design the details of the circular array of magnetic sensors for current measurement in practical situations.

  11. Post-tensioning tendon force loss detection using low power pulsed eddy current measurement

    Science.gov (United States)

    Kim, Ji-Min; Lee, Jun; Sohn, Hoon

    2018-04-01

    In the field of bridge engineering, pre-fabrication of a bridge member and its construction in site have been issued and studied, which achieves improved quality and rapid construction. For integration of those pre-fabricated segments into a structural member (i.e., a concrete slab, girder and pier), post-tensioning (PT) technique is adopted utilizing a high-strength steel tendon, and an effective investigation of the remaining PT tendon force is essential to assure an overall structural integrity. This study proposes a pulsed eddy current based tendon force loss detection system. A compact eddy current sensor is designed to be installed on the surface of an anchor holding a steel PT tendon. The intensity of the induced eddy current varies with PT tendon force alteration due to the magnetostriction effect of a ferromagnetic material. The advantages of the proposed system are as follows: (1) low power consumption, (2) rapid inspection, and (3) simple installation. Its performance was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter mono-tendon that was tensioned using a universal testing machine. Tendon force was controlled from 20 to 180 kN with 20 kN interval, and eddy current responses were measured and analyzed at each force condition. The proposed damage index and the amount of force loss of PT tendon were monotonically related, and an excessive loss as much as 30 % of an initially-introduced tendon force was successfully predicted.

  12. Measured current drainage through holes in various dielectrics up to 2 kilovolts in a dilute plasma

    Science.gov (United States)

    Grier, N. T.; Mckinzie, D. J., Jr.

    1972-01-01

    The electron current drained from a plasma through approximately 0.05 cm diameter holes in eight possible space applicable dielectrics placed on a probe biased at voltages up to 2000 V dc have been determined both theoretically and experimentally. The dielectrics tested were Parylene C and N, Teflon FEP type C, Teflon TFE, Nomex, quartz 7940 Corning Glass, Mylar A, and Kapton H polymide film. A Laplace field was used to predict an upper limit for the drainage current. The measured current was less than the computed current for quartz, Teflon FEP, and the 0.0123 cm thick sample of Parylene N for all voltages tested. The drainage current through the other dielectrics became equal to or greater than the computed current at a voltage below 2000 V. The magnitudes of the currents were between 0.1 and 10 microamperes for most of the dielectrics.

  13. Capacitance measurement of Josephson tunnel junctions with microwave-induced dc quasiparticle tunneling currents

    International Nuclear Information System (INIS)

    Hamasaki, K.; Yoshida, K.; Irie, F.; Enpuku, K.

    1982-01-01

    The microwave response of the dc quasiparticle tunneling current in Josephson tunnel junctions, where the Josephson current is suppressed by an external magnetic field, has been studied quantitatively in order to clarify its characteristics as a probe for the measurement of the junction capacitance. Extensive experiments for both small and long junctions are carried out for distinguishing between microwave behaviors of lumped and distributed constant junctions. It is shown that the observed voltage dependence of the dc quasiparticle tunneling current modified by an applied rf field is in good agreement with a theoretical result which takes into account the influence of the microwave circuit connected to the junction. The comparison between theory and experiment gives the magnitude of the internal rf field in the junction. Together with the applied rf field, this internal rf field leads to the junction rf impedance which is dominated by the junction capacitance in our experimental condition. In the case of lumped junctions, this experimental rf impedance is in reasonable agreement with the theoretical one with the junction capacitance estimated from the Fiske step of the distributed junction fabricated on the same substrate; the obtained ratio of the experimental impedance to the theoretical one is approximately 0.6--1.7. In the case of distributed junctions, however, experimental values of their characteristic impedances are approximately 0.2--0.3 of theoretical values calculated by assuming the one-dimensional junction model and taking account of the standing-wave effect in the junction

  14. Measurement of Drug Craving in Persian Speaking Subjects; a Review on Current Experiences and Future Perspectives

    Directory of Open Access Journals (Sweden)

    Masoomeh Maarefvand

    2012-09-01

    Full Text Available Background: Drug craving is considered as one of the main cores of drug dependency and addiction. Multidimensionality of drug craving, its cultural-bounded features and its intra individual rapidly changing nature makes it difficult to be measured. Nowadays, regarding different psychometric approaches, there are various instruments available for measurement of different aspects of drug craving but mainly for Latin-based languages in North America and European countries. High prevalence and special conditions, and unique subcultures in substance abuse and addiction in many countries, like Iran, make the design of culturally validated instruments for drug craving assessment priority. Materials and Methods: Comprehensive review on drug craving measurement instruments for Persian speaking subjects have been performed by searching in databases (ELSEVIER, Science Direct and Scientific Information Database (SID and investigating of related documents on regional experiences. Results: In this article seven main categories of drug craving instruments have been reviewed focusing on validated versions in Persian language including: self-reports, reinforcement “proxies”, drug self administration, psycho physiological responding, neurobiological responding, cognitive processing and expressive methods. Conclusion: Reviewing on weak and strength points of each instrument group and national and regional experiences shows that designing and validating a new series of ecologically-validated instruments for multidimensional measurement of drug craving in different addiction subcultures should be prioritized to cover current methodological gaps in substance abuse studies in Iran.

  15. Ion current prediction model considering columnar recombination in alpha radioactivity measurement using ionized air transportation

    International Nuclear Information System (INIS)

    Naito, Susumu; Hirata, Yosuke; Izumi, Mikio; Sano, Akira; Miyamoto, Yasuaki; Aoyama, Yoshio; Yamaguchi, Hiromi

    2007-01-01

    We present a reinforced ion current prediction model in alpha radioactivity measurement using ionized air transportation. Although our previous model explained the qualitative trend of the measured ion current values, the absolute values of the theoretical curves were about two times as large as the measured values. In order to accurately predict the measured values, we reinforced our model by considering columnar recombination and turbulent diffusion, which affects columnar recombination. Our new model explained the considerable ion loss in the early stage of ion diffusion and narrowed the gap between the theoretical and measured values. The model also predicted suppression of ion loss due to columnar recombination by spraying a high-speed air flow near a contaminated surface. This suppression was experimentally investigated and confirmed. In conclusion, we quantitatively clarified the theoretical relation between alpha radioactivity and ion current in laminar flow and turbulent pipe flow. (author)

  16. Comparison between voltage by turn measured on different tokamaks operating in hybrid wave current drive regime

    International Nuclear Information System (INIS)

    Briffod, G.; Hoang, G.T.

    1987-06-01

    On a tokamak in a current drive operation with a hybrid wave, the R.F. current is estimated from the voltage drop by plasma turn generated by R.F. power application. This estimated current is not proportional to the injected power. There still exists in the plasma an electric field corresponding to the current part produced by induction. The role evaluation of this parameter on the current drive efficiency is important. In this report the relation voltage-R.F. current is studied on Petula and results on the voltage evolution by turn on different machines are compared [fr

  17. Model for an irreversible bias current in the superconducting qubit measurement process

    International Nuclear Information System (INIS)

    Hutchinson, G. D.; Williams, D. A.; Holmes, C. A.; Stace, T. M.; Spiller, T. P.; Barrett, S. D.; Milburn, G. J.; Hasko, D. G.

    2006-01-01

    The superconducting charge-phase ''quantronium'' qubit is considered in order to develop a model for the measurement process used in the experiment of Vion et al. [Science 296, 886 (2002)]. For this model we propose a method for including the bias current in the readout process in a fundamentally irreversible way, which to first order is approximated by the Josephson junction tilted-washboard potential phenomenology. The decohering bias current is introduced in the form of a Lindblad operator and the Wigner function for the current-biased readout Josephson junction is derived and analyzed. During the readout current pulse used in the quantronium experiment we find that the coherence of the qubit initially prepared in a symmetric superposition state is lost at a time of 0.2 ns after the bias current pulse has been applied, a time scale that is much shorter than the experimental readout time. Additionally we look at the effect of Johnson-Nyquist noise with zero mean from the current source during the qubit manipulation and show that the decoherence due to the irreversible bias current description is an order of magnitude smaller than that found through adding noise to the reversible tilted-washboard potential model. Our irreversible bias current model is also applicable to persistent-current-based qubits where the state is measured according to its flux via a small-inductance direct-current superconducting quantum interference device

  18. Study on UPF Harmonic Current Detection Method Based on DSP

    Energy Technology Data Exchange (ETDEWEB)

    Zhao, H J [Northwestern Polytechnical University, Xi' an 710072 (China); Pang, Y F [Xi' an University of Technology, Xi' an 710048 (China); Qiu, Z M [Xi' an University of Technology, Xi' an 710048 (China); Chen, M [Northwestern Polytechnical University, Xi' an 710072 (China)

    2006-10-15

    Unity power factor (UPF) harmonic current detection method applied to active power filter (APF) is presented in this paper. The intention of this method is to make nonlinear loads and active power filter in parallel to be an equivalent resistance. So after compensation, source current is sinusoidal, and has the same shape of source voltage. Meanwhile, there is no harmonic in source current, and the power factor becomes one. The mathematic model of proposed method and the optimum project for equivalent low pass filter in measurement are presented. Finally, the proposed detection method applied to a shunt active power filter experimental prototype based on DSP TMS320F2812 is developed. Simulation and experiment results indicate the method is simple and easy to implement, and can obtain the real-time calculation of harmonic current exactly.

  19. Measuring Zonal Transport Variability of the Antarctic Circumpolar Current Using GRACE Ocean Bottom Pressure

    Science.gov (United States)

    Makowski, J.; Chambers, D. P.; Bonin, J. A.

    2012-12-01

    Previous studies have suggested that ocean bottom pressure (OBP) can be used to measure the transport variability of the Antarctic Circumpolar Current (ACC). Using OBP data from the JPL ECCO model and the Gravity Recovery and Climate Experiment (GRACE), we examine the zonal transport variability of the ACC integrated between the major fronts between 2003-2010. The JPL ECCO data are used to determine average front positions for the time period studies, as well as where transport is mainly zonal. Statistical analysis will be conducted to determine the uncertainty of the GRACE observations using a simulated data set. We will also begin looking at low frequency changes and how coherent transport variability is from region to region of the ACC. Correlations with bottom pressure south of the ACC and the average basin transports will also be calculated to determine the probability of using bottom pressure south of the ACC as a means for describing the ACC dynamics and transport.

  20. Prospect for Charge Current Neutrino Interactions Measurements at the CERN-PS

    CERN Document Server

    Bernardini, P; Bozza, C; Brugnera, R; Cecchetti, A; Cecchini, S; Collazuol, G; Corso, F Dal; De Mitri, I; De Serio, M; Di Ferdinando, D; Dore, U; Dusini, S; Fabbricatore, P; Fanin, C; Fini, R A; Garfagnini, A; Grella, G; Kose, U; Laveder, M; Loverre, P; Longhin, A; Marsella, G; Mancarella, G; Mandrioli, G; Mauri, N; Medinaceli, E; Mezzetto, M; Muciaccia, M T; Orecchini, D; Paoloni, A; Pastore, A; Patrizii, L; Pozzato, M; Rescigno, R; Rosa, G; Simone, S; Sioli, M; Sirri, G; Spurio, M; Stanco, L; Stellacci, S; Surdo, A; Tenti, M; Togo, V

    2011-01-01

    Tensions in several phenomenological models grew with experimental results on neutrino/antineutrino oscillations at Short-Baseline (SBL) and with the recent, carefully recomputed, antineutrino fluxes from nuclear reactors. At a refurbished SBL CERN-PS facility an experiment aimed to address the open issues has been proposed [1], based on the technology of imaging in ultra-pure cryogenic Liquid Argon (LAr). Motivated by this scenario a detailed study of the physics case was performed. We tackled specific physics models and we optimized the neutrino beam through a full simulation. Experimental aspects not fully covered by the LAr detection, i.e. the measurements of the lepton charge on event-by-event basis and their energy over a wide range, were also investigated. Indeed the muon leptons from Charged Current (CC) (anti-)neutrino interactions play an important role in disentangling different phenomenological scenarios provided their charge state is determined. Also, the study of muon appearance/disappearance ca...

  1. Combined local current distribution measurements and high resolution neutron radiography of operating direct methanol fuel cells

    Energy Technology Data Exchange (ETDEWEB)

    Schroeder, Alexander; Wippermann, Klaus [Forschungszentrum Juelich GmbH (Germany). Inst. of Energy Research, IEF-3: Fuel Cells; Sanders, Tilman [RWTH Aachen (DE). Inst. for Power Electronics and Electrical Drives (ISEA); Arlt, Tobias [Helmholtz Centre Berlin (Germany). Inst. for Applied Materials

    2010-07-01

    Neutron radiography allows the investigation of the local fluid distribution in direct methanol fuel cells (DMFCs) under operating conditions. Spatial resolutions in the order of some tens of micrometers at the full test cell area are achieved. This offers the possibility to study practice-oriented, large stack cells with an active area of several hundred cm{sup 2} as well as specially designed, small test cells with an area of some cm{sup 2}. Combined studies of high resolution neutron radiography and segmented cell measurements are especially valuable, because they enable a correlation of local fluid distribution and local performance [1, 2]. The knowledge of this interdependency is essential to optimise the water management and performance respecting a homogeneous fluid, current and temperature distribution and to achieve high performance and durability of DMFCs. (orig.)

  2. Anthropometric measurements of tibial plateau and correlation with the current tibial implants.

    Science.gov (United States)

    Erkocak, Omer Faruk; Kucukdurmaz, Fatih; Sayar, Safak; Erdil, Mehmet Emin; Ceylan, Hasan Huseyin; Tuncay, Ibrahim

    2016-09-01

    The aim of the study was to make an anthropometric analysis at the resected surfaces of the proximal tibia in the Turkish population and to compare the data with the dimensions of tibial components in current use. We hypothesized that tibial components currently available on the market do not fulfil the requirements of this population and a new tibial component design may be required, especially for female patients with small stature. Anthropometric data from the proximal tibia of 226 knees in 226 Turkish subjects were measured using magnetic resonance imaging. We measured the mediolateral, middle anteroposterior, medial and lateral anteroposterior dimensions and the aspect ratio of the resected proximal tibial surface. All morphological data were compared with the dimensions of five contemporary tibial implants, including asymmetric and symmetric design types. The dimensions of the tibial plateau of Turkish knees demonstrated significant differences according to gender (P < 0.05). Among the different tibial implants reviewed, neither asymmetric nor symmetric designs exhibited a perfect conformity to proximal tibial morphology in size and shape. The vast majority of tibial implants involved in this study tend to overhang anteroposteriorly, and a statistically significant number of women (21 %, P < 0.05) had tibial anteroposterior diameters smaller than the smallest available tibial component. Tibial components designed according to anthropometric measurements of Western populations do not perfectly meet the requirements of Turkish population. These data could provide the basis for designing the optimal and smaller tibial component for this population, especially for women, is required for best fit. II.

  3. Glow-to-arc transition events in H2-Ar direct current pulsed plasma: Automated measurement of current and voltage

    International Nuclear Information System (INIS)

    Mendes, Luciano A.; Rodrigues, Jhonatam C.; Mafra, Marcio

    2012-01-01

    The glow-to-arc transition phenomena (arcing) observed in plasma reactors used in materials processing was studied through the arcs characteristic current and voltage waveforms. In order to capture these arcs signals, a LABVIEW based automated instrumentation system (ARCVIEW) was developed, including the integration of an oscilloscope equipped with proper current and voltage probes. The system also allows capturing the process parameters at the arc occurrence moments, which were used to map the arcs events conditions. Experiments in H 2 -Ar DC pulsed plasma returned signals data from 215 arcs events, which were analyzed through software routines. According to the results, an anti-arcing system should react in the time order of few microseconds to prevent most of the damage caused by the undesired arcing phenomena.

  4. Measurement of the current in water discharge using magneto-optical Faraday effect

    International Nuclear Information System (INIS)

    Sarkisov, G.S.; Woodworth, J.R.

    2006-01-01

    The observation of magnetooptical Faraday effects in water in experiments with electrical breakdown is presented. After high-voltage breakdown, the ionized channel with ∼4 kA current was generated. The magnetic field from the current channel induces a circular birefringence which results in rotation of the polarization plane of a probing laser (200 ps, 532 nm). In spite of fast opposite radius drop of the magnetic field in radial direction, the Faraday rotation effect drops very slowly. The rotation of the polarization plane was ∼0.65 deg. ±5%. The optical measurements are in good agreement within ∼7% with the electrical measurements of the current

  5. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    Science.gov (United States)

    Krauter, N.; Stefani, F.

    2017-10-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation.

  6. Design and construction of a faraday cup for measuring small electron currents

    International Nuclear Information System (INIS)

    Veyssiere, A.

    1967-01-01

    This paper describes the design of a device for measuring and integrating very small currents generated by the impact of a charged particle beam upon a Faraday cup. Part one considers the detector as such. The main component is a graphite bloc capable of stopping practically all the incident charges. Part two describes the associated electrode apparatus required to measure better than 10 -13 ampere with a precision- of 1 per cent: Integration of such weak currents over periods of several hours, in the presence of a strong background current, is also discussed. (author) [fr

  7. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    International Nuclear Information System (INIS)

    Krauter, N; Stefani, F

    2017-01-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation. (paper)

  8. Measurements of high-current electron beams from X pinches and wire array Z pinches

    International Nuclear Information System (INIS)

    Shelkovenko, T. A.; Pikuz, S. A.; Blesener, I. C.; McBride, R. D.; Bell, K. S.; Hammer, D. A.; Agafonov, A. V.; Romanova, V. M.; Mingaleev, A. R.

    2008-01-01

    Some issues concerning high-current electron beam transport from the X pinch cross point to the diagnostic system and measurements of the beam current by Faraday cups are discussed. Results of computer simulation of electron beam propagation from the pinch to the Faraday cup give limits for the measured current for beams having different energy spreads. The beam is partially neutralized as it propagates from the X pinch to a diagnostic system, but within a Faraday cup diagnostic, space charge effects can be very important. Experimental results show evidence of such effects.

  9. Solar cycle in current reanalyses: (non)linear attribution study

    Science.gov (United States)

    Kuchar, A.; Sacha, P.; Miksovsky, J.; Pisoft, P.

    2014-12-01

    This study focusses on the variability of temperature, ozone and circulation characteristics in the stratosphere and lower mesosphere with regard to the influence of the 11 year solar cycle. It is based on attribution analysis using multiple nonlinear techniques (Support Vector Regression, Neural Networks) besides the traditional linear approach. The analysis was applied to several current reanalysis datasets for the 1979-2013 period, including MERRA, ERA-Interim and JRA-55, with the aim to compare how this type of data resolves especially the double-peaked solar response in temperature and ozone variables and the consequent changes induced by these anomalies. Equatorial temperature signals in the lower and upper stratosphere were found to be sufficiently robust and in qualitative agreement with previous observational studies. The analysis also pointed to the solar signal in the ozone datasets (i.e. MERRA and ERA-Interim) not being consistent with the observed double-peaked ozone anomaly extracted from satellite measurements. Consequently the results obtained by linear regression were confirmed by the nonlinear approach through all datasets, suggesting that linear regression is a relevant tool to sufficiently resolve the solar signal in the middle atmosphere. Furthermore, the seasonal dependence of the solar response was also discussed, mainly as a source of dynamical causalities in the wave propagation characteristics in the zonal wind and the induced meridional circulation in the winter hemispheres. The hypothetical mechanism of a weaker Brewer Dobson circulation was reviewed together with discussion of polar vortex stability.

  10. Rocket-based measurement of Birkeland currents in an active post-midnight aurora

    International Nuclear Information System (INIS)

    Coley, W.R.

    1979-01-01

    At 10:45 U.T. on March 1, 1976, an instrumented payload was launched by a Nike-Tomahawk rocket from Poker Flat, Alaska. The payload passed over auroral breakup activity that had a visual intensity of about 150 kR. An electron detector covering the 8 to 10 keV energy range observed electron precipitation while a cesium vapor vector magnetometer measured magnetic perturbations along the vehicle trajectory. From the magnetic measurements a current system consisting of horizontal electrojets and two pairs of oppositely directed field-aligned current sheets was inferred. The total current density carried by these sheets is much larger than that carried by the energetic electrons alone; hence, other particles are the primary current carriers. Data provided by the Chatanika radar facility are used along with other ground-based data to obtain electric fields conductivity estimates, and current densities, which are compared to the currents measured by the flight magnetometer. Results indicate that the ionosphere acts as an electrical load, providing the closing current for Birkeland current flow being generated out in the magnetosphere

  11. Instrumentation for Gate Current Noise Measurements on sub-100 nm MOS Transistors

    CERN Document Server

    Gaioni, L; Ratti, L; Re, V; Speziali, V; Traversi, G

    2008-01-01

    This work describes a measuring system that was developed to characterize the gate current noise performances of CMOS devices with minimum feature size in the 100 nm span. These devices play an essential role in the design of present daymixedsignal integrated circuits, because of the advantages associated with the scaling process. The reduction in the gate oxide thickness brought about by CMOS technology downscaling leads to a non-negligible gate current due to direct tunneling phenomena; this current represents a noise source which requires an accurate characterization for optimum analog design. In this paper, two instruments able to perform measurements in two different ranges of gate current values will be discussed. Some of the results of gate current noise characterization will also be presented.

  12. Technique of Critical Current Density Measurement of Bulk Superconductor with Linear Extrapolation Method

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, Engkir; Winatapura, Didin S.

    2000-01-01

    Technique of critical current density measurement (Jc) of HTc bulk ceramic superconductor has been performed by using linear extrapolation with four-point probes method. The measurement of critical current density HTc bulk ceramic superconductor usually causes damage in contact resistance. In order to decrease this damage factor, we introduce extrapolation method. The extrapolating data show that the critical current density Jc for YBCO (123) and BSCCO (2212) at 77 K are 10,85(6) Amp.cm - 2 and 14,46(6) Amp.cm - 2, respectively. This technique is easier, simpler, and the use of the current flow is low, so it will not damage the contact resistance of the sample. We expect that the method can give a better solution for bulk superconductor application. Key words. : superconductor, critical temperature, and critical current density

  13. Measurement of plasma current in Tokamaks using an optical fibre reflectometry technique

    Directory of Open Access Journals (Sweden)

    Wuilpart Marc

    2018-01-01

    Full Text Available An optical time-domain reflectometer sensitive to the polarization of light is proposed for the measurement of plasma current in the Tore Supra fusion reactor. The measurement principle relies on the Faraday effect i.e. on the generation of a circular birefringence along an optical fiber subject to an axial magnetic field. The circular birefringence induces a polarization rotation that can be mapped along the fiber thanks to an opticaltime domain reflectometer followed by an linear polarizer. A proper fitting of the measurement trace then allows determining the applied plasma current. The sensor has been experimentally validated on the Tore Supra tokamak fusion reactor for a plasma current range going from 0.6 to 1.5 MA. A maximum error of 13.50% has been observed for the lowest current.

  14. PDF sensitivity studies from ATLAS measurements

    CERN Document Server

    Hanna, Remie; The ATLAS collaboration

    2015-01-01

    Several measurements performed by the ATLAS collaboration are either useful to constrain the proton structure or are affected by its associated uncertainties. The strange-quark density is rather poorly known at low x. Measurements of the W+c production and the inclusive W and Z differential cross sections are found to constrain the strange-quark density. Drell-Yan cross section measurements performed above and below the Z peak region have a different sensitivity to parton flavour, parton momentum fraction x and scale Q compared to measurements on the Z peak and can also be used to constrain the photon content of the proton. Measurements of the inclusive jet and photon cross sections are standard candles and can be useful to constrain the medium and high x gluon densities. Precision electroweak studies performed by ATLAS can be limited by the current knowledge on the proton structure. Among those are the measurement of the effective weak mixing angle and the mass of the W boson. Dedicated PDF studies were perf...

  15. Entrainment and mixing in lock-exchange gravity currents using simultaneous velocity-density measurements

    Science.gov (United States)

    Balasubramanian, Sridhar; Zhong, Qiang

    2018-05-01

    Gravity currents modify their flow characteristics by entraining ambient fluid, which depends on a variety of governing parameters such as the initial density, Δρ, the total initial height of the fluid, H, and the slope of the terrain, α, from where it is released. It is imperative to study the entrainment dynamics of a gravity current in order to have a clear understanding of mixing transitions that govern the flow physics, the velocity mixing layer thickness, δu, and the density mixing layer thickness, δρ. Experiments were conducted in a lock-exchange facility in which the dense fluid was separated from the ambient lighter fluid using a gate. As the gate is released instantaneously, an energy conserving gravity current is formed, for which the only governing parameter is the Reynolds number defined as R e =U/h ν , where U is the front velocity of the gravity current and h is the height of the current. In our study, the bulk Richardson number (inverse of Froude number, Fr), Rib = g/'H Ub2 = 1, takes a constant value for all the experiments, with Ub being the bulk velocity of the current defined as Ub = √{g'H }. Simultaneous particle image velocimetry and planar laser induced fluorescence measurement techniques are employed to get the velocity and density statistics. Using the buoyancy conservation equation, a new flux-based method was formulated for calculating the entrainment coefficient, EF, near the front and head of the propagating gravity current for a Reynolds number range of Re ≈ 485-12 270 used in our experiments. At the head of the current, the results show a mixing transition at Re ≈ 2700 that is attributed to the flow transitioning from weak Holmboe waves to Kelvin-Helmholtz instabilities, in the form of Kelvin-Helmholtz vortex rolls. Following this mixing transition, the entrainment coefficient continued to increase with increasing Reynolds number owing to the occurrence of three-dimensional Kelvin-Helmholtz billows that promote further

  16. Measurement of 3-Axis Magnetic Fields Induced by Current Wires Using a Smartphone in Magnetostatics Experiments

    Science.gov (United States)

    Setiawan, B.; Septianto, R. D.; Suhendra, D.; Iskandar, F.

    2017-01-01

    This paper describes the use of an inexpensive smartphone's magnetic sensor to measure magnetic field components (B[subscript x], B[subscript y] and B[subscript z]) induced by current wires in magnetostatic experiments. The variable parameters used to measure the magnetic sensor's capabilities were: the geometrical shapes of the wire, current…

  17. Particle image velocimetry measurements and numerical modeling of a saline density current

    CSIR Research Space (South Africa)

    Gerber, G

    2011-03-01

    Full Text Available Particle image velocimetry scalar measurements were carried out on the body of a stably stratified density current with an inlet Reynolds number of 2,300 and bulk Richardson number of 0.1. These measurements allowed the mass and momentum transport...

  18. Measuring Physical Inactivity: Do Current Measures Provide an Accurate View of “Sedentary” Video Game Time?

    Directory of Open Access Journals (Sweden)

    Simon Fullerton

    2014-01-01

    Full Text Available Background. Measures of screen time are often used to assess sedentary behaviour. Participation in activity-based video games (exergames can contribute to estimates of screen time, as current practices of measuring it do not consider the growing evidence that playing exergames can provide light to moderate levels of physical activity. This study aimed to determine what proportion of time spent playing video games was actually spent playing exergames. Methods. Data were collected via a cross-sectional telephone survey in South Australia. Participants aged 18 years and above (n=2026 were asked about their video game habits, as well as demographic and socioeconomic factors. In cases where children were in the household, the video game habits of a randomly selected child were also questioned. Results. Overall, 31.3% of adults and 79.9% of children spend at least some time playing video games. Of these, 24.1% of adults and 42.1% of children play exergames, with these types of games accounting for a third of all time that adults spend playing video games and nearly 20% of children’s video game time. Conclusions. A substantial proportion of time that would usually be classified as “sedentary” may actually be spent participating in light to moderate physical activity.

  19. Thermal conductivity measurement of HTS tapes and stacks for current lead applications

    International Nuclear Information System (INIS)

    Schwarz, Michael; Weiss, Klaus-Peter; Heller, Reinhard; Fietz, Walter H.

    2009-01-01

    The use of high-temperature-superconductors (HTS) within current leads offers a high potential to save cooling-power. The principle of HTS current leads is well established, e.g. for particle accelerators (LHC-CERN) but also on the commercial sector, which offer HTS current leads ready for use in small scale magnets and magnets systems. Future fusion machines currently under construction like ITER, W7-X or JT-60SA also will use HTS current leads. At the moment the standard material for HTS current leads is a Bi 2 Sr 2 Ca 2 Cu 3 O x (BSCCO)-AgAu composite tape. The common way to receive high current capacity current leads is to form stacks by sintering or soldering these tapes together. The solder changes the thermal conductivity of the stacks compared to the single tape in the temperature range from 4 K to 60 K. To estimate the heat flux from the warm environment to the cold application the measurement of the thermal conductivity of the soldered stack is mandatory. Therefore the thermal conductivity of stacks with different number of tapes is investigated. To measure the thermal conduction in the current flow direction, the axial heat flow method is used. Combining these results with FEM simulations gives the possibility to estimate the thermal conductivity normal to the flat tape plane. The resulting anisotropic thermal conductivity can be used to model the behaviour of the HTS tape under thermal disturbances more accurately.

  20. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.; Seidman, D.N.

    1977-01-01

    A novel Faraday cup is described which allows the simultaneous observation and measurement of ion-beam currents. The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA), which serves as the basis of an internal image intensification system (a gain of >10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion current which is measured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30-keV Ar + ion beam is presented as an illustrative example. We have also employed this Faraday cup to observe and measure 30-keV Cr + , Mo + , or W + , and 18-keV Au + ion beams employed for the in situ irradiation of field-ion microscope specimens

  1. Direct-reading inhalable dust monitoring--an assessment of current measurement methods.

    Science.gov (United States)

    Thorpe, Andrew; Walsh, Peter T

    2013-08-01

    Direct-reading dust monitors designed specifically to measure the inhalable fraction of airborne dust are not widely available. Current practice therefore often involves comparing the response of photometer-type dust monitors with the concentration measured with a reference gravimetric inhalable sampler, which is used to adjust the dust monitor measurement. However, changes in airborne particle size can result in significant errors in the estimation of inhalable concentration by this method. The main aim of this study was to assess how these dust monitors behave when challenged with airborne dust containing particles in the inhalable size range and also to investigate alternative dust monitors whose response might not be as prone to variations in particle size or that could be adapted to measure inhalable dust concentration. Several photometer-type dust monitors and a Respicon TM, tapered element oscillating microbalance (TEOM) personal dust monitor (PDM) 3600, TEOM 1400, and Dustrak DRX were assessed for the measurement of airborne inhalable dust during laboratory and field trials. The PDM was modified to allow it to sample and measure larger particles in the inhalable size range. During the laboratory tests, the dust monitors and reference gravimetric samplers were challenged inside a large dust tunnel with aerosols of industrial dusts known to present an inhalable hazard and aluminium oxide powders with a range of discrete particle sizes. A constant concentration of each dust type was generated and peak concentrations of larger particles were periodically introduced to investigate the effects of sudden changes in particle size on monitor calibration. The PDM, Respicon, and DataRam photometer were also assessed during field trials at a bakery, joinery, and a grain mill. Laboratory results showed that the Respicon, modified PDM, and TEOM 1400 observed good linearity for all types of dust when compared with measurements made with a reference IOM sampler; the

  2. Comparison between morphometric measurements os current herd Mangalarga Marchador males and breed champions

    Directory of Open Access Journals (Sweden)

    Juliano Martins Santiago

    2013-01-01

    Full Text Available Equines morphometric analysis is an important method of selection related to functionality of the species. Mangalarga Marchador is the most important horse Brazilian breed and its evolution can be observed in specialized exhibition where owners expase their herd with the breed exponents, adopting them as selection parameters. In this context the study aimed to compare the morphometric measures of Mangalarga Marchador males herd with the champions of breed, using as parameters breed standards and Eclectic System of Proportions for saddle horse. Experimental design was completely randomized and treatments were the Mangalarga Marchador male herd, represented by all horses registered from 2000 to 2012, wich had measurements stored in Associação Brasileira de Criadores do Cavalo Mangalarga Marchador (ABCCMM service studbook database, totaling 15,482 animals, and the champions of breed, represented by 222 horses champions who participated of the 29th, 30th or 31th Exposição Nacional do Cavalo Mangalarga Marchador. Variables evaluated were height at withers and at rump, length of the head, neck, dorse, rump, shoulder and body, width of head and of rump, thoracic perimeter and cannon perimeter. Average linear measurements were related to length of head, according to Eclectic System of Proportions for saddle horse. Results were submitted to variance analysis and averages were compared by Fisher test (p<0.05. Regarding the current herd of males Mangalarga Marchador, the champions of the race showed greater length of neck, dorse, rump and body, height at withers and at rump, width of rump, cannon perimeter and shorter length of the shoulder. It was concluded that although larger, the champions horses Mangalarga Marchador are proportionally similar to current herd. Mangalarga Marchador horses have not yet reached the height considered ideal by breed standard and their proportions are different from those recommended by Eclectic System of Proportions for

  3. A CO2 laser polarimeter for measurement of plasma current profile in Alcator C-Mod

    International Nuclear Information System (INIS)

    Ma, C.H.; Hutchinson, D.P.; Richards, R.K.; Irby, J.; Luke, T.

    1994-01-01

    A multichannel infrared polarimeter system for measurement of the plasma current profile in Alcator C-Mod has been designed, constructed, and tested. The system utilizes a cw CO 2 , laser at a wavelength of 10.6 μm. An electro-optic polarization-modulation technique has been used to achieve the high sensitivity required for the measurement. The recent results of the measurements as well as the feasibility of its application on ITER are presented

  4. Study of runaway current generation following disruptions in KSTAR

    International Nuclear Information System (INIS)

    Chen, Z Y; Kim, W C; Yu, Y W; England, A C; Yoo, J W; Hahn, S H; Yoon, S W; Lee, K D; Oh, Y K; Kwak, J G; Kwon, M

    2013-01-01

    The high fraction of runaway current conversion following disruptions has an important effect on the first wall for next-generation tokamaks. Because of the potentially severe consequences of a large full current runaway beam on the first wall in an unmitigated disruption, runaway suppression is given a high priority. The behavior of runaway currents both in spontaneous disruptions and in D 2 massive gas injection (MGI) shutdown experiments is investigated in the KSTAR tokamak. The experiments in KSTAR show that the toroidal magnetic field threshold, B T >2 T, for runaway generation is not absolute. A high fraction of runaway current conversion following spontaneous disruptions is observed at a much lower toroidal magnetic field of B T = 1.3 T. A dedicated fast valve for high-pressure gas injection with 39.7 bar is developed for the study of disruptions. A study of runaway current parameters shows that the conversion efficiency of pre-disruptive plasma currents into runaway current can reach over 80% both in spontaneous disruptions and in D 2 MGI shutdown experiments in KSTAR. (paper)

  5. Uncertainty estimates of purity measurements based on current information: toward a "live validation" of purity methods.

    Science.gov (United States)

    Apostol, Izydor; Kelner, Drew; Jiang, Xinzhao Grace; Huang, Gang; Wypych, Jette; Zhang, Xin; Gastwirt, Jessica; Chen, Kenneth; Fodor, Szilan; Hapuarachchi, Suminda; Meriage, Dave; Ye, Frank; Poppe, Leszek; Szpankowski, Wojciech

    2012-12-01

    To predict precision and other performance characteristics of chromatographic purity methods, which represent the most widely used form of analysis in the biopharmaceutical industry. We have conducted a comprehensive survey of purity methods, and show that all performance characteristics fall within narrow measurement ranges. This observation was used to develop a model called Uncertainty Based on Current Information (UBCI), which expresses these performance characteristics as a function of the signal and noise levels, hardware specifications, and software settings. We applied the UCBI model to assess the uncertainty of purity measurements, and compared the results to those from conventional qualification. We demonstrated that the UBCI model is suitable to dynamically assess method performance characteristics, based on information extracted from individual chromatograms. The model provides an opportunity for streamlining qualification and validation studies by implementing a "live validation" of test results utilizing UBCI as a concurrent assessment of measurement uncertainty. Therefore, UBCI can potentially mitigate the challenges associated with laborious conventional method validation and facilitates the introduction of more advanced analytical technologies during the method lifecycle.

  6. Measuring retrograde autobiographical amnesia following electroconvulsive therapy: historical perspective and current issues.

    Science.gov (United States)

    Semkovska, Maria; McLoughlin, Declan M

    2013-06-01

    Retrograde amnesia following electroconvulsive therapy (ECT) is a major concern for both patients and clinicians. In contemporary ECT research, retrograde autobiographical amnesia (RAA) is commonly measured with instruments assessing autobiographical memory (AM) consistency over time. However, normal AM recall loses in consistency with the passage of time, and time has a differential effect on stability of personal memories. In addition, experiencing depression is associated with a decreased ability to recall specific AMs, and this difficulty may persist in the euthymic phase of recurrent depression. Despite these scientific facts, relatively few attempts have been made to accurately measure the specific effect of ECT on AM independent of both normal and mood-associated forgetting over time. This major gap in our knowledge prevents us at present from objectively quantifying the nature and extent of RAA associated with ECT. In turn, this hinders our identifying and implementing strategies for prevention or remediation of AM deficits. The present article aims to provide an up-to-date review and historical perspective of this major methodological conundrum for ECT research, highlight current issues in retrograde amnesia assessment following ECT, and propose directions for future studies. In conclusion, we suggest methods to reliably and specifically measure the extent and progression over time of ECT-associated RAA independently from persistent depressive symptoms' contribution and normal loss in AM consistency over time.

  7. Anodal transcranial direct current stimulation reduces psychophysically measured surround suppression in the human visual cortex.

    Directory of Open Access Journals (Sweden)

    Daniel P Spiegel

    Full Text Available Transcranial direct current stimulation (tDCS is a safe, non-invasive technique for transiently modulating the balance of excitation and inhibition within the human brain. It has been reported that anodal tDCS can reduce both GABA mediated inhibition and GABA concentration within the human motor cortex. As GABA mediated inhibition is thought to be a key modulator of plasticity within the adult brain, these findings have broad implications for the future use of tDCS. It is important, therefore, to establish whether tDCS can exert similar effects within non-motor brain areas. The aim of this study was to assess whether anodal tDCS could reduce inhibitory interactions within the human visual cortex. Psychophysical measures of surround suppression were used as an index of inhibition within V1. Overlay suppression, which is thought to originate within the lateral geniculate nucleus (LGN, was also measured as a control. Anodal stimulation of the occipital poles significantly reduced psychophysical surround suppression, but had no effect on overlay suppression. This effect was specific to anodal stimulation as cathodal stimulation had no effect on either measure. These psychophysical results provide the first evidence for tDCS-induced reductions of intracortical inhibition within the human visual cortex.

  8. Comparison of HF radar measurements with Eulerian and Lagrangian surface currents

    Science.gov (United States)

    Röhrs, Johannes; Sperrevik, Ann Kristin; Christensen, Kai Håkon; Broström, Göran; Breivik, Øyvind

    2015-05-01

    High-frequency (HF) radar-derived ocean currents are compared with in situ measurements to conclude if the radar observations include effects of surface waves that are of second order in the wave amplitude. Eulerian current measurements from a high-resolution acoustic Doppler current profiler and Lagrangian measurements from surface drifters are used as references. Directional wave spectra are obtained from a combination of pressure sensor data and a wave model. Our analysis shows that the wave-induced Stokes drift is not included in the HF radar-derived currents, that is, HF radars measure the Eulerian current. A disputed nonlinear correction to the phase velocity of surface gravity waves, which may affect HF radar signals, has a magnitude of about half the Stokes drift at the surface. In our case, this contribution by nonlinear dispersion would be smaller than the accuracy of the HF radar currents, hence no conclusion can be made. Finally, the analysis confirms that the HF radar data represent an exponentially weighted vertical average where the decay scale is proportional to the wavelength of the transmitted signal.

  9. Internal magnetic probe measurements of MHD activity and current profiles in a tokamak

    International Nuclear Information System (INIS)

    Giannone, L.; Cross, R.C.

    1987-01-01

    Mirnov oscillations and plasma disruptions in the TORTUS tokamak have been studied by using both internal and external magnetic probe arrays. The internal probe was also used to measure the plasma current distribution so that results could be compared with resistive tearing mode calculations. The growth of m = 3, 4 and 5 modes was found to be consistent with linear tearing mode theory before a disruption but not after it. The observed mode amplitudes, typically b θ /B θ ∼ 5%, were much larger than theoretical estimates based on the magnetic energy available to drive the modes. Despite the presence of large islands near the limiter, most of the disruptions observed were associated with rapid growth of internal modes. (author). 23 refs, 14 figs

  10. Internal magnetic probe measurements of MHD activity and current profiles in a tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Giannone, L.; Cross, R C; Hutchinson, I H

    1987-01-01

    Mirnov oscillations and plasma disruptions in the TORTUS tokamak have been studied by using both internal and external magnetic probe arrays. The internal probe was also used to measure the plasma current distribution so that results could be compared with resistive tearing mode calculations. The growth of m = 3, 4 and 5 modes was found to be consistent with linear tearing mode theory before a disruption but not after it. The observed mode amplitudes, typically b/sub theta//B/sub theta/ approx. 5%, were much larger than theoretical estimates based on the magnetic energy available to drive the modes. Despite the presence of large islands near the limiter, most of the disruptions observed were associated with rapid growth of internal modes. (author). 23 refs, 14 figs.

  11. Field mapping measurements to determine spatial and field dependence of critical current density in YBCO tapes

    International Nuclear Information System (INIS)

    Leclerc, J.; Berger, K.; Douine, B.; Lévêque, J.

    2013-01-01

    Highlights: • A method for characterizing superconducting tapes from field mapping is presented. • A new and efficient field mapping apparatus has been setup. • This method allows the spatial characterization of superconducting tapes. • The critical current density is obtained as a function of the flux density. • This method has been experimentally tested on an YBCO tape. -- Abstract: In this paper a measurement method that allows the determination of the critical current density of superconducting tape from field mapping measurements is presented. This contact-free method allows obtaining characteristics of the superconductor as a function of the position and of the applied flux density. With some modifications, this technique can be used for reel-to-reel measurements. The determination of the critical current density is based on an inverse calculation. This involves calculating the current distribution in the tape from magnetic measurements. An YBaCuO tape has been characterized at 77 K. A defect in this superconductor has been identified. Various tests were carried out to check the efficiency of the method. The inverse calculation was tested theoretically and experimentally. Comparison with a transport current measurement was also performed

  12. Technical Note: Influence of Compton currents on profile measurements in small-volume ion chambers

    Energy Technology Data Exchange (ETDEWEB)

    Tanny, Sean; Sperling, Nicholas; Parsai, E. Ishmael, E-mail: e.parsai@utoledo.edu [Department of Radiation Oncology, University of Toledo Medical Center, 1325 Conference Drive, Toledo, Ohio 43614 (United States); Holmes, Shannon [Standard Imaging, 3120 Deming Way, Middleton, Wisconsin 53562 (United States)

    2015-10-15

    Purpose: This work is to evaluate the effects of Compton current generation in three small-volume ionization chambers on measured beam characteristics for electron fields. Methods: Beam scans were performed using Exradin A16, A26, and PTW 31014 microchambers. Scans with varying chamber components shielded were performed. Static point measurements, output factors, and cable only irradiations were performed to determine the contribution of Compton currents to various components of the chamber. Monte Carlo simulations were performed to evaluate why one microchamber showed a significant reduction in Compton current generation. Results: Beam profiles demonstrated significant distortion for two of the three chambers when scanned parallel to the chamber axis, produced by electron deposition within the wire. Measurements of ionization produced within the cable identified Compton current generation as the cause of these distortions. The size of the central collecting wire was found to have the greatest influence on the magnitude of Compton current generation. Conclusions: Microchambers can demonstrate significant (>5%) deviations from properties as measured with larger volume chambers (0.125 cm{sup 3} and above). These deviations can be substantially reduced by averaging measurements conducted at opposite polarities.

  13. Ocean currents and acoustic backscatter data from shipboard ADCP measurements at three North Atlantic seamounts between 2004 and 2015

    OpenAIRE

    Mohn, Christian; Denda, Anneke; Christiansen, Svenja; Kaufmann, Manfred; Peine, Florian; Springer, Barbara; Turnewitsch, Robert; Christiansen, Bernd

    2018-01-01

    Seamounts are amongst the most common physiographic structures of the deep-ocean landscape, but remoteness and geographic complexity have limited the systematic collection of integrated and multidisciplinary data in the past. Consequently, important aspects of seamount ecology and dynamics remain poorly studied. We present a data collection of ocean currents and raw acoustic backscatter from shipboard Acoustic Doppler Current Profiler (ADCP) measurements during six cruises between 2004 and 20...

  14. Suspended sediment dynamics in a large-scale turbidity current: Direct measurements from the deep-water Congo Canyon

    Science.gov (United States)

    Simmons, S.; Azpiroz, M.; Cartigny, M.; Clare, M. A.; Parsons, D. R.; Sumner, E.; Talling, P. J.

    2016-12-01

    Turbidity currents that transport sediment to the deep ocean deposit a greater volume of sediment than any other process on Earth. To date, only a handful of studies have directly measured turbidity currents, with flow durations ranging from a few minutes to a few hours. Our understanding of turbidity current dynamics is therefore largely derived from scaled laboratory experiments and numerical modelling. Recent years have seen the first field-scale measurements of depth-resolved velocity profiles, but sediment concentration (a key parameter for turbidity currents) remains elusive. Here, we present high resolution measurements of deep-water turbidity currents from the Congo Canyon; one of the world's largest submarine canyons. Direct measurements using acoustic Doppler current profilers (ADCPs) show that flows can last for many days, rather than hours as seen elsewhere, and provide the first quantification of concentration and grain size within deep-water turbidity currents.Velocity and backscatter were measured at 5 second intervals by an ADCP suspended 80 m above the canyon floor, at 2000 m water depth. A novel inversion method using multiple ADCP frequencies enabled quantification of sediment concentration and grain size within the flows. We identify high concentrations of coarse sediment within a thin frontal cell, which outruns a thicker, trailing body. Thus, the flows grow in length while propagating down-canyon. This is distinct from classical models and other field-scale measurements of turbidity currents. The slow-moving body is dominated by suspended fine-grained sediment. The body mixes with the surrounding fluid leaving diffuse clouds of sediment that persist for days after initial entrainment. Ambient tidal flow also controls the mixing within the body and the surrounding fluid. Our results provide a new quantification of suspended sediment within flows and the interaction with the surrounding fluid.

  15. Theoretical derivation of anodizing current and comparison between fitted curves and measured curves under different conditions

    Science.gov (United States)

    Chong, Bin; Yu, Dongliang; Jin, Rong; Wang, Yang; Li, Dongdong; Song, Ye; Gao, Mingqi; Zhu, Xufei

    2015-04-01

    Anodic TiO2 nanotubes have been studied extensively for many years. However, the growth kinetics still remains unclear. The systematic study of the current transient under constant anodizing voltage has not been mentioned in the original literature. Here, a derivation and its corresponding theoretical formula are proposed to overcome this challenge. In this paper, the theoretical expressions for the time dependent ionic current and electronic current are derived to explore the anodizing process of Ti. The anodizing current-time curves under different anodizing voltages and different temperatures are experimentally investigated in the anodization of Ti. Furthermore, the quantitative relationship between the thickness of the barrier layer and anodizing time, and the relationships between the ionic/electronic current and temperatures are proposed in this paper. All of the current-transient plots can be fitted consistently by the proposed theoretical expressions. Additionally, it is the first time that the coefficient A of the exponential relationship (ionic current jion = A exp(BE)) has been determined under various temperatures and voltages. And the results indicate that as temperature and voltage increase, ionic current and electronic current both increase. The temperature has a larger effect on electronic current than ionic current. These results can promote the research of kinetics from a qualitative to quantitative level.

  16. Theoretical derivation of anodizing current and comparison between fitted curves and measured curves under different conditions.

    Science.gov (United States)

    Chong, Bin; Yu, Dongliang; Jin, Rong; Wang, Yang; Li, Dongdong; Song, Ye; Gao, Mingqi; Zhu, Xufei

    2015-04-10

    Anodic TiO2 nanotubes have been studied extensively for many years. However, the growth kinetics still remains unclear. The systematic study of the current transient under constant anodizing voltage has not been mentioned in the original literature. Here, a derivation and its corresponding theoretical formula are proposed to overcome this challenge. In this paper, the theoretical expressions for the time dependent ionic current and electronic current are derived to explore the anodizing process of Ti. The anodizing current-time curves under different anodizing voltages and different temperatures are experimentally investigated in the anodization of Ti. Furthermore, the quantitative relationship between the thickness of the barrier layer and anodizing time, and the relationships between the ionic/electronic current and temperatures are proposed in this paper. All of the current-transient plots can be fitted consistently by the proposed theoretical expressions. Additionally, it is the first time that the coefficient A of the exponential relationship (ionic current j(ion) = A exp(BE)) has been determined under various temperatures and voltages. And the results indicate that as temperature and voltage increase, ionic current and electronic current both increase. The temperature has a larger effect on electronic current than ionic current. These results can promote the research of kinetics from a qualitative to quantitative level.

  17. Near-surface current meter array measurements of internal gravity waves

    Energy Technology Data Exchange (ETDEWEB)

    Jones, H.B.E. [Lawrence Livermore National Lab., CA (United States)

    1994-11-15

    We have developed various processing algorithms used to estimate the wave forms produced by hydrodynamic Internal Waves. Furthermore, the estimated Internal Waves are used to calculate the Modulation Transfer Function (MTF) which relates the current and strain rate subsurface fields to surface scattering phenomenon imaged by radar. Following a brief discussion of LLNL`s measurement platform (a 10 sensor current meter array) we described the generation of representative current and strain rate space-time images from measured or simulated data. Then, we present how our simulation capability highlighted limitations in estimating strain rate. These limitations spurred the application of beamforming techniques to enhance our estimates, albeit at the expense of collapsing our space-time images to 1-D estimates. Finally, we discuss progress with regard to processing the current meter array data captured during the recent Loch Linnhe field trials.

  18. Spin correlation and entanglement detection in Cooper pair splitters by current measurements using magnetic detectors

    Science.gov (United States)

    Busz, Piotr; Tomaszewski, Damian; Martinek, Jan

    2017-08-01

    We analyze a model of a double quantum dot Cooper pair splitter coupled to two ferromagnetic detectors and demonstrate the possibility of determination of spin correlation by current measurements. We use perturbation theory, taking account of the exchange interaction with the detectors, which leads to complex spin dynamics in the dots. This affects the measured spin and restricts the use of ferromagnetic detectors to the nonlinear current-voltage characteristic regime at the current plateau, where the relevant spin projection is conserved, in contrast to the linear current-voltage characteristic regime, in which the spin information is distorted. Moreover, we show that for separable states the spin correlation can only be determined in a limited parameter regime, much more restricted than in the case of entangled states. We propose an entanglement test based on the Bell inequality.

  19. Current status of studies on temperature fluctuation phenomena in LMFRs

    International Nuclear Information System (INIS)

    Ohshima, H.; Muramatsu, T.; Kobayashi, J.; Yamaguchi, A.

    1994-01-01

    This paper describes the current status of studies being performed in PNC on temperature fluctuation phenomena occurring in fast reactors. The studies concentrate on four problems: thermal stratification, thermal striping, core-plenum interaction and free surface sloshing. Both experimental and analytical approaches to reveal these phenomena and to establish design and safety evaluation methods are presented together with future works. (author)

  20. Current Highlights on ESA's Planetary Technology Reference Studies

    Science.gov (United States)

    Falkner, P.

    The concept of Technology Reference Studies has been introduced already at EGU05, where the Venus Entry Probe (VEP), the Jupiter Minisat Explorer (JME), the Deimos Sample Return (DSR) and the Interstellar Heliopause Probe (IHP) have been presented in detail. At the EGU06 the new studies in reaction to the Cosmic Vision exercise have been introduced. The formulation of themes and mapping into potential future missions has been taken as basis in the planning of additional new and adaptation of existing TRS's to cover areas, which have not yet been addressed by any TRS. These new ongoing studies are progressing well and current highlights will be presented in the paper in further detail as well as an overview on supporting technology studies and Concurrent Design Facility (CDF) sessions. The Jupiter System Explorer (JSE) study investigates mission concepts with up to two Magnetospheric Orbiters placed in a highly elliptical Jovian orbit and the possibility to deploy a Jovian Entry Probe. The mission profile is based on a solar powered concept launched on a Soyuz-Fregat launcher. Mission analysis and the application of a new Jovian radiation model are supporting the study activities. The Near-Earth Asteroid Sample Return (NEA-SR) concept explores the possibilities of sample return or in-situ mission profiles with visits to up to two NEA targets. Due to the assumed low cost cap a trade between a sample return and remote/in-situ exploration concept has a high attention in the study. The Cross Scale TRS (CS-TRS) is intended to simultaneously investigate magnetospheric and plasma processes in three spatial scales with a formation flight of up to 12 spacecraft, orbiting on deep elliptical orbits around Earth. One of the major challenges is the launch of that number of spacecraft on a single launcher and the collisionless deployment of the formation at the target orbit. The scope if the GeoSail TRS is to demonstrate deployment, attitude control and navigation concepts for a

  1. The artificial object detection and current velocity measurement using SAR ocean surface images

    Science.gov (United States)

    Alpatov, Boris; Strotov, Valery; Ershov, Maksim; Muraviev, Vadim; Feldman, Alexander; Smirnov, Sergey

    2017-10-01

    Due to the fact that water surface covers wide areas, remote sensing is the most appropriate way of getting information about ocean environment for vessel tracking, security purposes, ecological studies and others. Processing of synthetic aperture radar (SAR) images is extensively used for control and monitoring of the ocean surface. Image data can be acquired from Earth observation satellites, such as TerraSAR-X, ERS, and COSMO-SkyMed. Thus, SAR image processing can be used to solve many problems arising in this field of research. This paper discusses some of them including ship detection, oil pollution control and ocean currents mapping. Due to complexity of the problem several specialized algorithm are necessary to develop. The oil spill detection algorithm consists of the following main steps: image preprocessing, detection of dark areas, parameter extraction and classification. The ship detection algorithm consists of the following main steps: prescreening, land masking, image segmentation combined with parameter measurement, ship orientation estimation and object discrimination. The proposed approach to ocean currents mapping is based on Doppler's law. The results of computer modeling on real SAR images are presented. Based on these results it is concluded that the proposed approaches can be used in maritime applications.

  2. Numerical study of gravity currents in a channel

    International Nuclear Information System (INIS)

    Wang, D.

    1985-01-01

    A three-dimensional, primitive-equation model was used to study gravity currents produced by instantaneous releases of a buoyant fluid in a rectangular channel. Without rotation, the gravity current passes through two distinct phases: an initial adjustment phase in which the front speed is constant, and an eventual self-similar phase in which the front speed decreases with time. With rotation, the gravity current is confined to the right-hand wall, forming a coastal jet. The initial front-speed is constant; however, the front speed decreases rapidly due to strong mixing at the horizontal edge of the gravity current. Also, with rotation, part of the buoyant fluid is trapped near the source region, forming an anticyclonic vortex

  3. Inductive current measurements in an oriented grained YBa2Cu3Ox superconductor

    International Nuclear Information System (INIS)

    Kupfer, H.; Keller, C.; Salama, K.; Selvamanickam, V.

    1989-01-01

    The critical current of grain aligned YBa 2 Cu 3 O x bulk material was investigated by inductive flux profile and ac susceptibility measurements. The induced current was directed perpendicular to the a-b plane oriented grains where high values of the transport current, have been previously reported. In spite of the unfavorable geometry of the investigated shielding current, no features of granularity were observed. The results yield a uniform bulk critical current density j c of 3x10 4 A/cm 2 at zero field and 77 K. Field and temperature dependences of this j c are discussed and compared with those in a granular Y-Ba-Cu-O material

  4. Measurement of current drive profile using electron cyclotron wave attenuation near the O-mode cutoff

    International Nuclear Information System (INIS)

    Fidone, I.; Meyer, R.L.; Caron, X.

    1992-01-01

    A method for determining the radial profile of the lower-hybrid current drive in tokamaks using electron cyclotron attenuation of the O mode for frequencies ω near the cutoff frequency is discussed. The basic idea is that, for a given wave frequency, the cutoff plays the role of a spatial filter selecting a variable portion of the noninductive current. It is shown that the incremental attenuation resulting from a small increase of ω displays specific features related to the current density near the cutoff point. Using the relation between the wave damping and the current density, it is possible to determine the radial profile of the current drive from the wave attenuation measurements. A numerical application is also presented for plasma parameters in the reactor regime

  5. Critical current measurement in superconducting rings using an automatic inductive technique

    International Nuclear Information System (INIS)

    Gonzalez-Jorge, H.; Linares, B.; Quelle, I.; Carballo, E.; Romani, L.; Domarco, G.

    2007-01-01

    A measurement technique was developed to identify the critical current of superconducting rings. It is based on the detection of the voltage on a secondary coil when the current induced in the superconductor by a primary one go beyond to the critical value. The technique uses a DC power supply to control the AC current circulating by the primary circuit. Such circuit mainly consists on an AC power supply which gives a constant AC voltage, a primary inducting coil and a control coil with iron core. The AC current circulating by this circuit is modified with the change in the impedance of the control coil due to the fact of the DC current supplied by the power supply in parallel with it

  6. A self-discharge model of Lithium-Sulfur batteries based on direct shuttle current measurement

    DEFF Research Database (Denmark)

    Knap, Vaclav; Stroe, Daniel Loan; Swierczynski, Maciej Jozef

    2016-01-01

    . A simple but comprehensive mathematical model of the Li-S battery cell self-discharge based on the shuttle current was developed and is presented. The shuttle current values for the model parameterization were obtained from the direct shuttle current measurements. Furthermore, the battery cell depth......-of-discharge values were recomputed in order to account for the influence of the self-discharge and provide a higher accuracy of the model. Finally, the derived model was successfully validated against laboratory experiments at various conditions....

  7. Detecting Single-Nucleotides by Tunneling Current Measurements at Sub-MHz Temporal Resolution.

    Science.gov (United States)

    Morikawa, Takanori; Yokota, Kazumichi; Tanimoto, Sachie; Tsutsui, Makusu; Taniguchi, Masateru

    2017-04-18

    Label-free detection of single-nucleotides was performed by fast tunneling current measurements in a polar solvent at 1 MHz sampling rate using SiO₂-protected Au nanoprobes. Short current spikes were observed, suggestive of trapping/detrapping of individual nucleotides between the nanoelectrodes. The fall and rise features of the electrical signatures indicated signal retardation by capacitance effects with a time constant of about 10 microseconds. The high temporal resolution revealed current fluctuations, reflecting the molecular conformation degrees of freedom in the electrode gap. The method presented in this work may enable direct characterizations of dynamic changes in single-molecule conformations in an electrode gap in liquid.

  8. Relationship between PC index and magnetospheric field-aligned currents measured by Swarm satellites

    DEFF Research Database (Denmark)

    Troshichev, О.; Sormakov, D.; Behlke, R.

    2018-01-01

    Abstract The relationship between the magnetospheric field-aligned currents (FAC) monitored by the Swarm satellites and the magnetic activity PC index (which is a proxy of the solar wind energy incoming into the magnetosphere) is examined. It is shown that current intensities measured in the R1...... between the PC index and the intensity of field-aligned currents in the R1 dawn and dusk layers: increase of FAC intensity in the course of substorm development is accompanied by increasing the PC index values. Correlation between PC and FAC intensities in the R2 dawn and dusk layers is also observed...

  9. Eddy-current flow rate meter for measuring sodium flow rates

    International Nuclear Information System (INIS)

    Knaak, J.

    1976-01-01

    For safety reasons flow rate meters for monitoring coolant flow rates are inserted in the core of sodium-cooled fast breeder reactors. These are so-called eddy-current flow rate meters which can be mounted directly above the fuel elements. In the present contribution the principle of measurement, the mechanical construction and the circuit design of the flow rate measuring device are described. Special problems and their solution on developing the measuring system are pointed out. Finally, results of measurement and experience with the apparatus in several experiments are reported, where also further possibilities of application were tested. (orig./TK) [de

  10. The current status of eye lens dose measurement in interventional cardiology personnel in Thailand.

    Science.gov (United States)

    Krisanachinda, Anchali; Srimahachota, Suphot; Matsubara, Kosuke

    2017-06-01

    Workers involved in interventional cardiology procedures receive high eye lens doses if radiation protection tools are not properly utilized. Currently, there is no suitable method for routine measurement of eye dose. In Thailand, the eye lens equivalent doses in terms of Hp(3) of the interventional cardiologists, nurses, and radiographers participating in interventional cardiology procedures have been measured at 12 centers since 2015 in the pilot study. The optically stimulated luminescence (OSL) dosimeter was used for measurement of the occupational exposure and the eye lens dose of 42 interventional cardiology personnel at King Chulalongkorn Memorial Hospital as one of the pilot centers. For all personnel, it is recommended that a first In Light OSL badge is placed at waist level and under the lead apron for determination of Hp(10); a second badge is placed at the collar for determination of Hp(0.07) and estimation of Hp(3). Nano Dots OSL dosimeter has been used as an eye lens dosimeter for 16 interventional cardiology personnel, both with and without lead-glass eyewear. The mean effective dose at the body, equivalent dose at the collar, and estimated eye lens dose were 0.801, 5.88, and 5.70 mSv per year, respectively. The mean eye lens dose measured by the Nano Dots dosimeter was 8.059 mSv per year on the left eye and 3.552 mSv per year on the right eye. Two of 16 interventional cardiologists received annual eye lens doses on the left side without lead glass that were higher than 20 mSv per year, the new eye lens dose limit as recommended by ICRP with the risk of eye lens opacity and cataract.

  11. Method and apparatus for remote tube crevice detection by current and voltage probe resistance measurement

    Science.gov (United States)

    Kikta, Thomas J.; Mitchell, Ronald D.

    1992-01-01

    A method and apparatus for determining the extent of contact between an electrically conducting tube and an electrically conductive tubesheet surrounding the tube, based upon the electrical resistance of the tube and tubesheet. A constant current source is applied to the interior of the electrically conducting tube by probes and a voltmeter is connected between other probes to measure the voltage at the point of current injection, which is inversely proportional to the amount of contact between the tube and tubesheet. Namely, the higher the voltage measured by the voltmeter, the less contact between the tube and tubesheet.

  12. Design, Fabrication and Temperature Sensitivity Testing of a Miniature Piezoelectric-Based Sensor for Current Measurements

    Directory of Open Access Journals (Sweden)

    Steven B. Lao

    2014-07-01

    Full Text Available Grid capacity, reliability, and efficient distribution of power have been major challenges for traditional power grids in the past few years. Reliable and efficient distribution within these power grids will continue to depend on the development of lighter and more efficient sensing units with lower costs in order to measure current and detect failures across the grid. The objective of this paper is to present the development of a miniature piezoelectric-based sensor for AC current measurements in single conductors, which are used in power transmission lines. Additionally presented in this paper are the thermal testing results for the sensor to assess its robustness for various operating temperatures.

  13. Evaluation of the Kinetic Property of Single-Molecule Junctions by Tunneling Current Measurements.

    Science.gov (United States)

    Harashima, Takanori; Hasegawa, Yusuke; Kiguchi, Manabu; Nishino, Tomoaki

    2018-01-01

    We investigated the formation and breaking of single-molecule junctions of two kinds of dithiol molecules by time-resolved tunneling current measurements in a metal nanogap. The resulting current trajectory was statistically analyzed to determine the single-molecule conductance and, more importantly, to reveal the kinetic property of the single-molecular junction. These results suggested that combining a measurement of the single-molecule conductance and statistical analysis is a promising method to uncover the kinetic properties of the single-molecule junction.

  14. First measurement of charged current cross sections at HERA with longitudinally polarised positrons

    Science.gov (United States)

    H1 Collaboration; Aktas, A.; Andreev, V.; Anthonis, T.; Antunovic, B.; Aplin, S.; Asmone, A.; Astvatsatourov, A.; Babaev, A.; Backovic, S.; Bähr, J.; Baghdasaryan, A.; Baranov, P.; Barrelet, E.; Bartel, W.; Baudrand, S.; Baumgartner, S.; Becker, J.; Beckingham, M.; Behnke, O.; Behrendt, O.; Belousov, A.; Berger, Ch.; Berger, N.; Bizot, J. C.; Boenig, M.-O.; Boudry, V.; Bracinik, J.; Brandt, G.; Brisson, V.; Bruncko, D.; Büsser, F. W.; Bunyatyan, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A. J.; Cassol-Brunner, F.; Cerny, K.; Cerny, V.; Chekelian, V.; Contreras, J. G.; Coughlan, J. A.; Cox, B. E.; Cozzika, G.; Cvach, J.; Dainton, J. B.; Dau, W. D.; Daum, K.; de Boer, Y.; Delcourt, B.; Del Degan, M.; de Roeck, A.; Desch, K.; de Wolf, E. A.; Diaconu, C.; Dodonov, V.; Dubak, A.; Eckerlin, G.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Elsen, E.; Erdmann, W.; Essenov, S.; Falkewicz, A.; Faulkner, P. J. W.; Favart, L.; Fedotov, A.; Feltesse, J.; Ferencei, J.; Finke, L.; Fleischer, M.; Fleischmann, P.; Flucke, G.; Fomenko, A.; Foresti, I.; Franke, G.; Frisson, T.; Gabathuler, E.; Garutti, E.; Gayler, J.; Gerlich, C.; Ghazaryan, S.; Ginzburgskaya, S.; Glazov, A.; Glushkov, I.; Goerlich, L.; Goettlich, M.; Gogitidze, N.; Gorbounov, S.; Goyon, C.; Grab, C.; Greenshaw, T.; Gregori, M.; Grell, B. R.; Grindhammer, G.; Gwilliam, C.; Haidt, D.; Hajduk, L.; Hansson, M.; Heinzelmann, G.; Henderson, R. C. W.; Henschel, H.; Herrera, G.; Hildebrandt, M.; Hiller, K. H.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Hreus, T.; Hussain, S.; Ibbotson, M.; Ismail, M.; Jacquet, M.; Janauschek, L.; Janssen, X.; Jemanov, V.; Jönsson, L.; Johnson, D. P.; Jung, A. W.; Jung, H.; Kapichine, M.; Katzy, J.; Kenyon, I. R.; Kiesling, C.; Klein, M.; Kleinwort, C.; Klimkovich, T.; Kluge, T.; Knies, G.; Knutsson, A.; Korbel, V.; Kostka, P.; Krastev, K.; Kretzschmar, J.; Kropivnitskaya, A.; Krüger, K.; Kückens, J.; Landon, M. P. J.; Lange, W.; Laštovička, T.; Laštovička-Medin, G.; Laycock, P.; Lebedev, A.; Leibenguth, G.; Lendermann, V.; Levonian, S.; Lindfeld, L.; Lipka, K.; Liptaj, A.; List, B.; List, J.; Lobodzinska, E.; Loktionova, N.; Lopez-Fernandez, R.; Lubimov, V.; Lucaci-Timoce, A.-I.; Lueders, H.; Lüke, D.; Lux, T.; Lytkin, L.; Makankine, A.; Malden, N.; Malinovski, E.; Mangano, S.; Marage, P.; Marshall, R.; Martisikova, M.; Martyn, H.-U.; Maxfield, S. J.; Meer, D.; Mehta, A.; Meier, K.; Meyer, A. B.; Meyer, H.; Meyer, J.; Michels, V.; Mikocki, S.; Milcewicz-Mika, I.; Milstead, D.; Mladenov, D.; Mohamed, A.; Moreau, F.; Morozov, A.; Morris, J. V.; Mozer, M. U.; Müller, K.; Murín, P.; Nankov, K.; Naroska, B.; Naumann, Th.; Newman, P. R.; Niebuhr, C.; Nikiforov, A.; Nowak, G.; Nozicka, M.; Oganezov, R.; Olivier, B.; Olsson, J. E.; Osman, S.; Ozerov, D.; Palichik, V.; Panagoulias, I.; Papadopoulou, T.; Pascaud, C.; Patel, G. D.; Peng, H.; Perez, E.; Perez-Astudillo, D.; Perieanu, A.; Petrukhin, A.; Pitzl, D.; Plačakytė, R.; Portheault, B.; Povh, B.; Prideaux, P.; Rahmat, A. J.; Raicevic, N.; Reimer, P.; Reisert, B.; Rimmer, A.; Risler, C.; Rizvi, E.; Robmann, P.; Roland, B.; Roosen, R.; Rostovtsev, A.; Rurikova, Z.; Rusakov, S.; Salvaire, F.; Sankey, D. P. C.; Sauvan, E.; Schätzel, S.; Schmidt, S.; Schmitt, S.; Schmitz, C.; Schoeffel, L.; Schöning, A.; Schultz-Coulon, H.-C.; Sedlák, K.; Sefkow, F.; Shaw-West, R. N.; Sheviakov, I.; Shtarkov, L. N.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, A.; Steder, M.; Stella, B.; Stiewe, J.; Strauch, I.; Straumann, U.; Sunar, D.; Tchoulakov, V.; Thompson, G.; Thompson, P. D.; Tomasz, F.; Traynor, D.; Truöl, P.; Tsakov, I.; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Tzamariudaki, E.; Urban, K.; Urban, M.; Usik, A.; Utkin, D.; Valkárová, A.; Vallée, C.; van Mechelen, P.; Vargas Trevino, A.; Vazdik, Y.; Veelken, C.; Vinokurova, S.; Volchinski, V.; Wacker, K.; Wagner, J.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Wessels, M.; Wessling, B.; Wigmore, C.; Wissing, Ch.; Wolf, R.; Wünsch, E.; Xella, S.; Yan, W.; Yeganov, V.; Žáček, J.; Zálešák, J.; Zhang, Z.; Zhelezov, A.; Zhokin, A.; Zhu, Y. C.; Zimmermann, J.; Zimmermann, T.; Zohrabyan, H.; Zomer, F.

    2006-03-01

    Data taken with positrons of different longitudinal polarisation states in collision with unpolarised protons at HERA are used to measure the total cross sections of the charged current process, ep→ν¯X, for negative four-momentum transfer squared Q>400 GeV and inelasticity y<0.9. Together with the corresponding cross section obtained from the previously published unpolarised data, the polarisation dependence of the charged current cross section is measured for the first time at high Q and found to be in agreement with the Standard Model prediction.

  15. Measuring currents, ice drift, and waves from space: the Sea surface KInematics Multiscale monitoring (SKIM) concept

    Science.gov (United States)

    Ardhuin, Fabrice; Aksenov, Yevgueny; Benetazzo, Alvise; Bertino, Laurent; Brandt, Peter; Caubet, Eric; Chapron, Bertrand; Collard, Fabrice; Cravatte, Sophie; Delouis, Jean-Marc; Dias, Frederic; Dibarboure, Gérald; Gaultier, Lucile; Johannessen, Johnny; Korosov, Anton; Manucharyan, Georgy; Menemenlis, Dimitris; Menendez, Melisa; Monnier, Goulven; Mouche, Alexis; Nouguier, Frédéric; Nurser, George; Rampal, Pierre; Reniers, Ad; Rodriguez, Ernesto; Stopa, Justin; Tison, Céline; Ubelmann, Clément; van Sebille, Erik; Xie, Jiping

    2018-05-01

    We propose a satellite mission that uses a near-nadir Ka-band Doppler radar to measure surface currents, ice drift and ocean waves at spatial scales of 40 km and more, with snapshots at least every day for latitudes 75 to 82°, and every few days for other latitudes. The use of incidence angles of 6 and 12° allows for measurement of the directional wave spectrum, which yields accurate corrections of the wave-induced bias in the current measurements. The instrument's design, an algorithm for current vector retrieval and the expected mission performance are presented here. The instrument proposed can reveal features of tropical ocean and marginal ice zone (MIZ) dynamics that are inaccessible to other measurement systems, and providing global monitoring of the ocean mesoscale that surpasses the capability of today's nadir altimeters. Measuring ocean wave properties has many applications, including examining wave-current interactions, air-sea fluxes, the transport and convergence of marine plastic debris and assessment of marine and coastal hazards.

  16. Measuring currents, ice drift, and waves from space: the Sea surface KInematics Multiscale monitoring (SKIM concept

    Directory of Open Access Journals (Sweden)

    F. Ardhuin

    2018-05-01

    Full Text Available We propose a satellite mission that uses a near-nadir Ka-band Doppler radar to measure surface currents, ice drift and ocean waves at spatial scales of 40 km and more, with snapshots at least every day for latitudes 75 to 82°, and every few days for other latitudes. The use of incidence angles of 6 and 12° allows for measurement of the directional wave spectrum, which yields accurate corrections of the wave-induced bias in the current measurements. The instrument's design, an algorithm for current vector retrieval and the expected mission performance are presented here. The instrument proposed can reveal features of tropical ocean and marginal ice zone (MIZ dynamics that are inaccessible to other measurement systems, and providing global monitoring of the ocean mesoscale that surpasses the capability of today's nadir altimeters. Measuring ocean wave properties has many applications, including examining wave–current interactions, air–sea fluxes, the transport and convergence of marine plastic debris and assessment of marine and coastal hazards.

  17. Study of Grants, new Mexico, uranium miners: current status

    International Nuclear Information System (INIS)

    Samet, J.M.; Morgan, M.V.; Buechley, R.W.; Key, C.R.; Valdivia, A.A.

    1981-01-01

    The Uranium Epidemiology Study at the University of New Mexico was initiated in 1977 with the objective of assessing health effects of uranium mining in the Grants, New Mexico, area. The planned approach was a cohort study of mortality that would capitalize on the availability of health records at the Grants Clinic. The first year's work confirmed the study's feasibility (Buechley, 1979). Subsequent efforts have focused on the health and exposure data base and comprehensive follow-up. A retrospective cohort study of early miners is in progress; a prospective cohort study of miners who began working under the current federal standard is planned. This report will summarize the current status of the Uranium Epidemiology Study

  18. Measuring discharge with acoustic Doppler current profilers from a moving boat

    Science.gov (United States)

    Mueller, David S.; Wagner, Chad R.; Rehmel, Michael S.; Oberg, Kevin A.; Rainville, Francois

    2013-01-01

    The use of acoustic Doppler current profilers (ADCPs) from a moving boat is now a commonly used method for measuring streamflow. The technology and methods for making ADCP-based discharge measurements are different from the technology and methods used to make traditional discharge measurements with mechanical meters. Although the ADCP is a valuable tool for measuring streamflow, it is only accurate when used with appropriate techniques. This report presents guidance on the use of ADCPs for measuring streamflow; this guidance is based on the experience of U.S. Geological Survey employees and published reports, papers, and memorandums of the U.S. Geological Survey. The guidance is presented in a logical progression, from predeployment planning, to field data collection, and finally to post processing of the collected data. Acoustic Doppler technology and the instruments currently (2013) available also are discussed to highlight the advantages and limitations of the technology. More in-depth, technical explanations of how an ADCP measures streamflow and what to do when measuring in moving-bed conditions are presented in the appendixes. ADCP users need to know the proper procedures for measuring discharge from a moving boat and why those procedures are required, so that when the user encounters unusual field conditions, the procedures can be adapted without sacrificing the accuracy of the streamflow-measurement data.

  19. Liner velocity, current, and symmetry measurements on the 32 MA flux compression generator experiment ALT-1

    CERN Document Server

    Clark, D A; Rodríguez, G; Tabaka, L J

    2001-01-01

    Summary form only given, as follows. A flux compression generator based pulse power system, designed, built, and fielded by a Russian team at the All Russian Scientific Research Institute of Experimental Physics (VNIIEF), was used to successfully drive an aluminum liner to velocities greater than 10 km/sec. The experiment objective was to demonstrate performance of a precision liner implosion at Atlas current of 30 MA or greater. Diagnostics to measure liner performance were an essential part of the experiment. An experimental team from Los Alamos National Laboratory (LANL) provided a suite of diagnostics to measure liner performance. Three diagnostics were fielded. 1. a velocity interferometer (VISAR) to continuously measure the liner inner surface velocity from throughout the entire range of travel. 2. Two Faraday rotation devices to measure liner current during the implosion. 3. Sixteen fiber optic impact pins to record liner impact time and provide axial and azimuthal symmetry information. All diagnostics...

  20. Simulation of the transient eddy current measurement for the characterization of depth and conductivity of a plate

    International Nuclear Information System (INIS)

    Cheng, Weiying; Komura, Ichiro

    2008-01-01

    A transient eddy current measurement method is presented to determine the thickness and conductivity of a conductive plate. The conductive plate is induced by an air-cored coil, the magnetic flux density along the axial is measured and the various signals corresponding to plates with different thickness and conductivity are calculated using a 3D transient eddy current simulator. Characteristic features are obtained from the transient response. A similarity-based modeling method is utilized in this study to estimate the thickness and conductivity of the conductive plate. (author)

  1. Critical current measurements of high Tc superconductors in a scanning low temperature cryostat

    International Nuclear Information System (INIS)

    Telschow, K.L.; O'Brien, T.K.

    1991-01-01

    Maintaining uniformity of properties over long distances is one of the fabrication problems encountered with the new high T c superconductors. Uniform properties are crucial in long tapes or wires with high critical current since local nonuniformities can limit the current carrying capacity of the whole piece. Transport critical currents in high T c superconductors are conventionally measured with the contact 4-point probe DC current-voltage technique. This technique requires contact with the sample and and spatially averages over the region between the two voltage contacts. Two techniques have been used to infer the critical state model. The first uses the net magnetization of a suitably shaped sample in an external magnetic field. The second combines a DC magnetic field with AC induced currents to infer spatial flux profiles. The AC magnetization technique offers an advantage in that it is noncontacting; however, it also averages the measurement over a large area and requires that the sample be shaped and positioned such that it exhibits zero demagnetizing factor. This paper describes a measurement technique and a scanning cryostat assembly that are capable of determining local critical current in a tape or wire with high resolution and without any direct sample electrical contact. A small compensated coil was used to induce AC currents in slab-shaped samples. The coil was situated near the surface on one side of the slab. With this method, the AC probe can be used as a noncontacting dissipation probe, replacing the voltage probe in the 4-point contact method, when an externally driven transport current is used, or by itself as a local critical state generator and dissipation detector. The results are shown to be meaningful even when the internal magnetic field is not uniform due to shape demagnetizing effects. 10 refs., 5 figs

  2. Measurement of azimuthal asymmetries in neutral current deep inelastic scattering at HERA

    International Nuclear Information System (INIS)

    Chekanov, S.; Derrick, M.; Magill, S.

    2007-01-01

    The distribution of the azimuthal angle of charged and neutral hadrons relative to the lepton plane has been studied for neutral current deep inelastic ep scattering using an integrated luminosity of 45 pb -1 taken with the ZEUS detector. The kinematic range is 100 2 2 , 0.2 2 is the virtuality of the exchanged boson, y is the inelasticity and x is the Bjorken variable. The measurements were made in the hadronic centre-of-mass system. The analysis exploits the energy-flow method, which allows the measurement to be made over a larger range of pseudorapidity compared to previous results. The dependence of the moments of the azimuthal distributions on the pseudorapidity and minimum transverse energy of the final-state hadrons are presented. Although the predictions from next-to-leading-order QCD describe the data better than do the Monte Carlo models incorporating leading-logarithm parton showers, they still fail to describe the magnitude of the asymmetries. This suggests that higher-order calculations may be necessary to describe these data. (orig.)

  3. High-resolution disruption halo current measurements using Langmuir probes in Alcator C-Mod

    Science.gov (United States)

    Tinguely, R. A.; Granetz, R. S.; Berg, A.; Kuang, A. Q.; Brunner, D.; LaBombard, B.

    2018-01-01

    Halo currents generated during disruptions on Alcator C-Mod have been measured with Langmuir ‘rail’ probes. These rail probes are embedded in a lower outboard divertor module in a closely-spaced vertical (poloidal) array. The dense array provides detailed resolution of the spatial dependence (~1 cm spacing) of the halo current distribution in the plasma scrape-off region with high time resolution (400 kHz digitization rate). As the plasma limits on the outboard divertor plate, the contact point is clearly discernible in the halo current data (as an inversion of current) and moves vertically down the divertor plate on many disruptions. These data are consistent with filament reconstructions of the plasma boundary, from which the edge safety factor of the disrupting plasma can be calculated. Additionally, the halo current ‘footprint’ on the divertor plate is obtained and related to the halo flux width. The voltage driving halo current and the effective resistance of the plasma region through which the halo current flows to reach the probes are also investigated. Estimations of the sheath resistance and halo region resistivity and temperature are given. This information could prove useful for modeling halo current dynamics.

  4. Detecting aberrant opioid behavior in the emergency department: a prospective study using the screener and Opioid Assessment for Patients with Pain-Revised (SOAPP®-R), Current Opioid Misuse Measure (COMM)™, and provider gestalt.

    Science.gov (United States)

    Varney, Shawn M; Perez, Crystal A; Araña, Allyson A; Carey, Katherine R; Ganem, Victoria J; Zarzabal, Lee A; Ramos, Rosemarie G; Bebarta, Vikhyat S

    2018-03-03

    Emergency department (ED) providers have limited time to evaluate patients at risk for opioid misuse. A validated tool to assess the risk for aberrant opioid behavior may mitigate adverse sequelae associated with prescription opioid misuse. We sought to determine if SOAPP-R, COMM, and provider gestalt were able to identify patients at risk for prescription opioid misuse as determined by pharmacy records at 12 months. We conducted a prospective observational study of adult patients in a high volume US ED. Patients completed the SOAPP-R and COMM, and treating EM providers evaluated patients' opioid misuse risk. We performed variable-centered, person-centered, and hierarchical cluster analyses to determine whether provider gestalt, SOAPP-R, or COMM, or a combination, predicted higher misuse risk. The primary outcome was the number of opioid prescriptions at 12 months according to pharmacy records. For 169 patients (mean age 43 years, 51% female, 73% white), correlation analysis showed a strong relationship between SOAPP-R and COMM with predicting the number of opioid prescriptions dispensed at 12 months. Provider scores estimating opioid misuse were not related to SOAPP-R and only weakly associated with COMM. In our adjusted regression models, provider gestalt and SOAPP-R uniquely predicted opioid prescriptions at 6 and 12 months. Using designated cutoff scores, only SOAPP-R detected a difference in the number of opioid prescriptions. Cluster analysis revealed that provider gestalt, SOAPP-R, and COMM scores jointly predicted opioid prescriptions. Provider gestalt and self-report instruments uniquely predicted the number of opioid prescriptions in ED patients. A combination of gestalt and self-assessment scores can be used to identify at-risk patients who otherwise miss the cutoff scores for SOAPP-R and COMM.

  5. Modeling, measurement, and 3-D equilibrium reconstruction of the bootstrap current in the Helically Symmetric Experiment

    Energy Technology Data Exchange (ETDEWEB)

    Schmitt, J. C.; Talmadge, J. N.; Anderson, D. T. [Department of Electrical and Computer Engineering, University of Wisconsin-Madison, Madison, Wisconsin 53706 (United States); Hanson, J. D. [Department of Physics, Auburn University, Auburn, Alabama 36849 (United States)

    2014-09-15

    The bootstrap current for three electron cyclotron resonance heated plasma scenarios in a quasihelically symmetric stellarator (the Helically Symmetric Experiment) are analyzed and compared to a neoclassical transport code PENTA. The three conditions correspond to 50 kW input power with a resonance that is off-axis, 50 kW on-axis heating and 100 kW on-axis heating. When the heating location was moved from off-axis to on-axis with 50 kW heating power, the stored energy and the extrapolated steady-state current were both observed to increase. When the on-axis heating power was increased from 50 kW to 100 kW, the stored energy continued to increase while the bootstrap current slightly decreased. This trend is qualitatively in agreement with the calculations which indicate that a large positive electric field for the 100 kW case was driving the current negative in a small region close to the magnetic axis and accounting for the decrease in the total integrated current. This trend in the calculations is only observed to occur when momentum conservation between particle species is included. Without momentum conservation, the calculated bootstrap current increases monotonically. We show that the magnitude of the bootstrap current as calculated by PENTA agrees better with the experiment when momentum conservation between plasma species is included in the calculation. The total current was observed in all cases to flow in a direction to unwind the transform, unlike in a tokamak in which the bootstrap current adds to the transform. The 3-D inductive response of the plasma is simulated to predict the evolution of the current profile during the discharge. The 3-D equilibrium reconstruction code V3FIT is used to reconstruct profiles of the plasma pressure and current constrained by measurements with a set of magnetic diagnostics. The reconstructed profiles are consistent with the measured plasma pressure profile and the simulated current profile when the

  6. A Measurement of Coherent Neutral Pion Production in Neutrino Neutral Current Interactions in NOMAD experiment

    CERN Document Server

    Kullenberg, C T

    2009-01-01

    We present a study of exclusive neutral pion production in neutrino-nucleus Neutral Current interactions using data from the NOMAD experiment at the CERN SPS. The data correspond to $1.44 \\times 10^6$ muon-neutrino Charged Current interactions in the energy range $2.5 \\leq E_{\

  7. Measurement of electron- and ion beam energies and currents in a plasma focus discharge

    International Nuclear Information System (INIS)

    Yamamoto, Toshikazu; Kondoh, Yoshiomi; Shimoda, Katsuji; Hirano, Katsumi

    1982-01-01

    Measurements of energetic particle beams in a plsma focus with a Mather type device are presented. Rogowski coils are used for time-resolved measurement, and solid-state nuclear track detectors for time-integrated measurement of the beams. In the upstream direction with respect to the discharge current, only the electron beam with the maximum current of several kA was detected, which was approximately one percent of the discharge current. The electron energies of the beam were spread from 0.1 to 1 MeV. In the downstream direction, two successive emissions of ions were observed. The first emission had an extremely high energy of the order of some MeV and a low beam current of less than 10 A. The second emission, the main part of the ion beam, with energies of 100 - 800 keV, followed the first one with a time lag of several tens of nanoseconds, and the beam current reached several tens of amperes. (author)

  8. Plasma bullet current measurements in a free-stream helium capillary jet

    Science.gov (United States)

    Oh, Jun-Seok; Walsh, James L.; Bradley, James W.

    2012-06-01

    A commercial current monitor has been used to measure the current associated with plasma bullets created in both the positive and negative half cycles of the sinusoidal driving voltage sustaining a plasma jet. The maximum values of the positive bullet current are typically ˜750 µA and persist for 10 µs, while the peaks in the negative current of several hundred μA are broad, persisting for about 40 µs. From the time delay of the current peaks with increasing distance from the jet nozzle, an average bullet propagation speed has been measured; the positive and negative bullets travel at 17.5 km s-1 and 3.9 km s-1 respectively. The net space charge associated with the bullet(s) has also been calculated; the positive and negative bullets contain a similar net charge of the order of 10-9 C measured at all monitor positions, with estimated charged particle densities nb of ˜1010-1011 cm-3 in the bullet.

  9. Plasma bullet current measurements in a free-stream helium capillary jet

    International Nuclear Information System (INIS)

    Oh, Jun-Seok; Walsh, James L; Bradley, James W

    2012-01-01

    A commercial current monitor has been used to measure the current associated with plasma bullets created in both the positive and negative half cycles of the sinusoidal driving voltage sustaining a plasma jet. The maximum values of the positive bullet current are typically ∼750 µA and persist for 10 µs, while the peaks in the negative current of several hundred μA are broad, persisting for about 40 µs. From the time delay of the current peaks with increasing distance from the jet nozzle, an average bullet propagation speed has been measured; the positive and negative bullets travel at 17.5 km s −1 and 3.9 km s −1 respectively. The net space charge associated with the bullet(s) has also been calculated; the positive and negative bullets contain a similar net charge of the order of 10 −9 C measured at all monitor positions, with estimated charged particle densities n b of ∼10 10 –10 11 cm −3 in the bullet. (special)

  10. Study program for constant current capacitor charging method

    Energy Technology Data Exchange (ETDEWEB)

    Pugh, C.

    1978-10-04

    The objective of the study program was to determine the best method of charging 20,000 to 132,000 microfarads of capacitance to 22 kVdc in 14 to 15 sec. Component costs, sizes, weights, line current graphs, copies of calculations and manufacturer's data are included.

  11. Current research projects on traffic conflicts technique studies.

    NARCIS (Netherlands)

    Hondel, M. van den & and Kraay, J.H.

    1979-01-01

    A review of current research concerning the development, evaluation and use of the traffic conflicts technique is presented. The 32 studies, selected from the IRRD data base, are listed alphabetically by names of countries and under countries by names of research organizations. The IRRD descriptions

  12. Subminiature eddy current transducers for studying boride coatings

    Science.gov (United States)

    Dmitriev, S. F.; Ishkov, A. V.; Malikov, V. N.; Sagalakov, A. M.

    2016-07-01

    Strengthening of parts and units of machines, increased reliability and longer service life is an important task of modern mechanical engineering. The main objects of study in the work were selected steel 65G and 50HGA, wear-resistant boride coatings ternary system Fe-B-Fe n B which were investigated by scanning electron microscopy and eddy-current nondestructive methods.

  13. Current density distribution mapping in PEM fuel cells as an instrument for operational measurements

    Energy Technology Data Exchange (ETDEWEB)

    Geske, M.; Heuer, M.; Heideck, G.; Styczynski, Z. A. [Otto-von-Guericke University Magdeburg, Chair Electric Power Networks and Renewable Energy Sources, Magdeburg (Germany)

    2010-07-01

    A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC). Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes. (author)

  14. Current Density Distribution Mapping in PEM Fuel Cells as An Instrument for Operational Measurements

    Directory of Open Access Journals (Sweden)

    Martin Geske

    2010-04-01

    Full Text Available A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC. Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes.

  15. Measurement by eddy currents of tube-antivibratory bar gap steam generators of PWR power plants

    International Nuclear Information System (INIS)

    Savin, E.; Bieth, M.; Floze, J.C.

    1990-01-01

    In steam generators tubes are maintained by AVB to limit vibrations amplitude induced by secondary fluid flow. After some years wear sometimes occurs. For gap measurement between tubes and AVB Framatome developed a method based on eddy current and using a probe rotating inside the tube [fr

  16. Lightning current distribution and hard radiation in aircraft, measured in-flight

    NARCIS (Netherlands)

    van Deursen, A.P.J.; Kochkin, P.; de Boer, A.; Bardet, M.; Allasia, C.; Boissin, J.F.; Flourens, F.

    2017-01-01

    The In-flight Lightning Damage Assessment System ILDAS has been presented in EMC Europe in 2012. ILDAS can determine the lightning current distribution on an aircraft with high resolution in time and amplitude. Later the system was extended and included two x-ray detectors to measure the high-energy

  17. Local Magnetic Measurements of Trapped Flux Through a Permanent Current Path in Graphite

    Science.gov (United States)

    Stiller, Markus; Esquinazi, Pablo D.; Quiquia, José Barzola; Precker, Christian E.

    2018-04-01

    Temperature- and field-dependent measurements of the electrical resistance of different natural graphite samples suggest the existence of superconductivity at room temperature in some regions of the samples. To verify whether dissipationless electrical currents are responsible for the trapped magnetic flux inferred from electrical resistance measurements, we localized them using magnetic force microscopy on a natural graphite sample in remanent state after applying a magnetic field. The obtained evidence indicates that at room temperature a permanent current flows at the border of the trapped flux region. The current path vanishes at the same transition temperature T_c≈ 370 K as the one obtained from electrical resistance measurements on the same sample. This sudden decrease in the phase is different from what is expected for a ferromagnetic material. Time-dependent measurements of the signal show the typical behavior of flux creep of a permanent current flowing in a superconductor. The overall results support the existence of room-temperature superconductivity at certain regions in the graphite structure and indicate that magnetic force microscopy is suitable to localize them. Magnetic coupling is excluded as origin of the observed phase signal.

  18. Electrooptic Methods for Measurement of Small DC Currents at High Voltage Level

    DEFF Research Database (Denmark)

    Tønnesen, Ole; Beatty, Neville; Skilbreid, Asbjørn Ottar

    1989-01-01

    collectors are connected via resistors RA and RB to the protective side of the voltage to be measured and the emitters to the negative side. The currents flowing in to the bases of the transistors are independently controlled by the light levels following on the two photodiodes PDA, PDB....

  19. Critical report of current fisheries management measures implemented for the North Sea mixed demersal fisheries

    DEFF Research Database (Denmark)

    Nielsen, J. Rasmus; Ulrich, Clara; Hegland, Troels J.

    The present report is an EU-FP7-SOCIOEC Report giving an overview and critical evaluation of the current management measures implemented for the North Sea mixed demersal fisheries and the fish stocks involved in this. Also, this involves review and critical evaluation of the scientific advice...

  20. Continuous measurements of discharge from a horizontal acoustic Doppler current profiler in a tidal river

    NARCIS (Netherlands)

    Hoitink, A.J.F.; Buschman, F.A.; Vermeulen, B.

    2009-01-01

    Acoustic Doppler current profilers (ADCPs) can be mounted horizontally at a river bank, yielding single-depth horizontal array observations of velocity across the river. This paper presents a semideterministic, semistochastic method to obtain continuous measurements of discharge from horizontal ADCP

  1. Limit on flavor-changing neutral currents from a measurement of neutrino-electron elastic scattering

    International Nuclear Information System (INIS)

    Krakauer, D.A.; Talaga, R.L.; Allen, R.C.; Chen, H.H.; Hausammann, R.; Lee, W.P.; Lu, X.; Mahler, H.J.; Wang, K.C.; Bowles, T.J.; Burman, R.L.; Carlini, R.D.; Cochran, D.R.F.; Doe, P.J.; Frank, J.S.; Potter, M.E.; Sandberg, V.D.; Piasetzky, E.

    1992-01-01

    From a measurement of the absolute cross section in ν ee - elastic scattering we have set a limit on flavor-changing neutral currents in the neutrino sector. We find that an off-diagonal, flavor-changing coupling is limited to 1-f ee <0.35 (90% C.L.)

  2. A review of the current literature on aetiology and measurement methods of halitosis.

    NARCIS (Netherlands)

    Broek, A.M. van den; Feenstra, L.; Baat, C. de

    2007-01-01

    OBJECTIVES: This work reviews the current knowledge of aetiology and measurement methods of halitosis. DATA: Halitosis is an unpleasant or offensive odour emanating from the breath. The condition is multifactorial and may involve both oral and non-oral conditions. SOURCES: A private, monthly with

  3. Transport measurements in superconductors: critical current of granular high TC ceramic superconductor samples

    International Nuclear Information System (INIS)

    Passos, W.A.C.

    2016-01-01

    This work presents a method to obtain critical current of granular superconductors. We have carried out transport measurements (ρxT curves and VxI curves) in a YBa_2Cu_3O_7_-_δ sample to determine critical current density of it. Some specimens reveal a 'semiconductor-like' behavior (electrical resistivity decreases with increasing temperatures above critical temperature T_c of material) competing with superconductor behavior. Due to high granular fraction of the sample, these competition is clearly noted in ρxT curves. Measurements carried out from 0 to 8500 Oe of applied field show the same behavior, and the critical current density of the samples is shown. (author)

  4. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    International Nuclear Information System (INIS)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan; Yang, Xinsheng; Zhao, Yong

    2015-01-01

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  5. Calibration of Hall sensor array for critical current measurement of YBCO tape with ferromagnetic substrate

    Energy Technology Data Exchange (ETDEWEB)

    Zhu, Yunpeng; Wang, Gang; Liu, Liyuan [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Yang, Xinsheng, E-mail: xsyang@swjtu.edu.cn [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Zhao, Yong [Key laboratory of Magnetic levitation Technologies and Maglev Trains (Ministry of Education), Superconductor and New Energy R& D Center, Mail Stop 165#, Southwest Jiaotong University, Chengdu, 610031 (China); Superconductivity Research Group, School of Materials Science and Engineering, University of New South Wale, Sydney 2052, NSW (Australia)

    2015-12-15

    Abstract : HAS (Hall sensor array) is a powerful tool to detect the uniformity of HTS (high temperature superconductor) tape through mapping the distribution of remanent or shielding field along the surface of the tape. However, measurement of HTS tape with ferromagnetic parts by HSA is still an issue because the ferromagnetic substrate has influence on the magnetic field around the HTS layer. In this work, a continuous HSA system has been designed to measure the critical current of the YBCO tape with ferromagnetic substrate. The relationship between the remanent field and critical current was calibrated by the finite element method. The result showed that the HSA is an effective method for evaluating the critical current of the HTS tape with ferromagnetic substrate. - Highlight: • A continuous Hall sensor array system has been designed. • The inhomogeneity of YBCO tape with ferromagnetic substrate can be detected by HAS. • Finite element method is an effective method for calibrating the remanent field.

  6. Application of thermally stimulated current measurement to the polymorphic characterization of drug substances

    International Nuclear Information System (INIS)

    Ikeda, Y.; Hirayama, T.; Terada, K.

    2005-01-01

    The thermal stimulated current measurement was used as an innovative analytical equipment to evaluate the polymorphic properties of terfenadine and Compound A, being developed by Takeda Pharmaceutical Company, Limited. At first, terfenadine, which is known to have polymorphs, was used as a model sample for thermally stimulated current (TSC) analyses. The TSC curves of amorphous and two polymorphs were distinctly different from each other. Therefore, it was considered that TSC measurement could be a useful technique to evaluate the crystalline properties of drug substances. The polymorphs of compound A were difficult to distinguish the characteristics of polymorphs from conventional powder X-ray diffractometry and also differential scanning calorimetry. Forms A and B of compound A were clearly differentiated by the thermal stimulated current properties that were adequate to characterize each form. Thus, it was shown that TSC was extremely useful and powerful tool for identification of complicated polymorphs, which were not distinguished by conventional methods

  7. A cryogenic current-measuring device with nano-ampere resolution at the storage ring TARN II

    International Nuclear Information System (INIS)

    Tanabe, T.; Chida, K.; Shinada, K.

    1999-01-01

    In cooler-ring experiments, an accurate and non-destructive current measurement is essential for determining the reaction cross sections. The lowest current which can be measured by the DC current transformer commonly used so far is some μA. In order to measure a low-beam current from nA to μA, we made a cryogenic current-measuring device using a superconducting quantum interference devices (SQUID), and measured the circulating ion current at the cooler ring TARN II. This paper gives the design and performance of the device

  8. Tube-AVB gap measurements using an eddy current rotating probe

    International Nuclear Information System (INIS)

    Badson, F.; Chiron, D.; Trumpff, B.

    1988-01-01

    The wears of tubes due to flow induced vibrations have been observed after a few years of operating PWR steam generators (SG). The vibration and wear are intimately related to the gap between tubes and anti-vibration bars (AVB's) located in the bundle. The authors report the development of an eddy current (EC) method for the measurement of this gap. The method is based on using an EC probe rotating in the tube. Since for each measurement zone the tube is interacting with two AVB's the use of a rotating EC probe is necessary to perform separate and accurate measurements of each tube-AVB gap

  9. Studies of current-perpendicular-to-plane magnetoresistance (CPP-MR) and current-induced magnetization switching (CIMS)

    Science.gov (United States)

    Kurt, Huseyin

    2005-08-01

    We present two CPP-MR studies of spin-valves based upon ferromagnetic/nonmagnetic/ferromagnetic (F/N/F) trilayers. We measure the spin-diffusion lengths of N = Pd, Pt, and Au at 4.2K, and both the specific resistances (sample area A times resistance R) and spin-memory-loss of N/Cu interfaces. Pd, Pt and Au are of special device interest because they give perpendicular anisotropy when sandwiching very thin Co layers. Comparing our spin-memory-loss data at Pd/Cu and Pt/Cu interfaces with older data for Nb/Cu and W/Cu gives insight into the importance of spin-orbit coupling in producing such loss. We reproduce and extend prior studies by Eid of 'magnetic activity' at the interface of Co and N-metals (or combinations of N-metals), when the other side of the N-metal contacts a superconductor (S). Our data suggest that magnetic activity may require strong spin-flipping at the N/S interface. We present five studies of a new phenomenon, CIMS, in F1/N/F2 trilayers, with F1 a thick 'polarizing' layer and F2 a thin 'switching' layer. In all prior studies of CIMS, positive current caused the magnetization of F2 to switch from parallel (P) to anti-parallel (AP) to that of F1- 'normal' switching. By judicious addition of impurities to F-metals, we are able to controllably produce both 'normal' and 'inverse' switching- where positive current switches the magnetization of F2 from AP to P to that of F1. In the samples studied, whether the switching is normal or inverse is set by the 'net polarization' produced by F1 and is independent of the properties of F2. As scattering in the bulk of F1 and F2 is essential to producing our results, these results cannot be described by ballistic models, which allow scattering only at interfaces. Most CIMS experiments use Cu as the N-layer due to its low resistivity and long spin-diffusion length. We show that Ag and Au have low enough resistivities and long enough spin-diffusion lengths to be useful alternatives to Cu for some devices. While

  10. Surface current dynamics under sea breeze conditions observed by simultaneous HF radar, ADCP and drifter measurements

    Science.gov (United States)

    Sentchev, Alexei; Forget, Philippe; Fraunié, Philippe

    2017-04-01

    Ocean surface boundary layer dynamics off the southern coast of France in the NW Mediterranean is investigated by using velocity observations by high-frequency (HF) radars, surface drifting buoys and a downward-looking drifting acoustic Doppler current profiler (ADCP). The analysis confirms that velocities measured by HF radars correspond to those observed by an ADCP at the effective depth z f = k -1, where k is wavenumber of the radio wave emitted by the radar. The radials provided by the radars were in a very good agreement with in situ measurements, with the relative errors of 1 and 9 % and root mean square (RMS) differences of 0.02 and 0.04 m/s for monostatic and bistatic radar, respectively. The total radar-based velocities appeared to be slightly underestimated in magnitude and somewhat biased in direction. At the end of the survey period, the difference in the surface current direction, based on HF radar and ADCP data, attained 10°. It was demonstrated that the surface boundary layer dynamics cannot be reconstructed successfully without taking into the account velocity variation with depth. A significant misalignment of ˜30° caused by the sea breeze was documented between the HF radar (HFR-derived) surface current and the background current. It was also found that the ocean response to a moderate wind forcing was confined to the 4-m-thick upper layer. The respective Ekman current attained the maximum value of 0.15 m/s, and the current rotation was found to be lagging the wind by approximately 40 min, with the current vector direction being 15-20° to the left of the wind. The range of velocity variability due to wind forcing was found comparable with the magnitude of the background current variability.

  11. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  12. Ionising radiation dosimetry by measuring thermally excited currents (TEC) in irradiated highpolymers

    International Nuclear Information System (INIS)

    Shtol'ts, V.; Petermann, V.; Nigot, V.

    1976-01-01

    The first results are presented in measuring thermally excited currents (TEC) in 60 Co - gamma irradiated polyethylene and teflon. The design of measuring instruments is described. The maximum background currents in nonirradiated samples reached 10 -13 A. The TEC curves are presented which have obtained under irradiation up to 0.1-1000 rad followed by heating in the temperature range from 20 to 250 deg C. The curves exhibited maxima at about 90 deg C for polyethylene and about 200 deg C for teflon. The TEC dose range has been determined to be 0.1-1000 rad and 5-1000 rad for polyethylene and teflon, respectively. The fading at room temperature after 100 hrs has appeared to be 50% for polyethylene and 60% for teflon. The main merit of the technique is assumed to be the simplicity of the measuring instruments [ru

  13. A population-based study of associations between current posttraumatic stress symptoms and current fatigue.

    Science.gov (United States)

    Lerdal, Anners; Lee, Kathryn A; Rokne, Berit; Knudsen, Øistein; Wahl, Astrid K; Dahl, Alv A

    2010-10-01

    This study explores current experience with posttraumatic stress disorder (PTSD) symptoms and other variables (sociodemographic, mental distress, somatic morbidity, self-rated health, and quality of life [QoL]) in relation to fatigue. A representative sample of the Norwegian population (N = 3,944) was invited to participate in a mailed survey, and 1,857 (47%) returned valid responses on the questionnaire that included the Fatigue Severity Scale and the Posttraumatic Symptom Scale-10. Posttraumatic stress disorder symptoms showed a strong association with fatigue in univariate (β = .41) and multivariate analyses (β = .33). Associations between psychosocial health variables, QoL, and fatigue were confirmed. However, PTSD symptoms showed the strongest association with fatigue in the analyses. Findings need to be replicated in other population samples and in clinical samples with PTSD and fatigue.

  14. Current Mode Neutron Noise Measurements in the Zero Power Reactor CROCUS

    Science.gov (United States)

    Pakari, O.; Lamirand, V.; Perret, G.; Braun, L.; Frajtag, P.; Pautz, A.

    2018-01-01

    The present article is an overview of developments and results regarding neutron noise measurements in current mode at the CROCUS zero power facility. Neutron noise measurements offer a non-invasive method to determine kinetic reactor parameters such as the prompt decay constant at criticality α = βeff / λ, the effective delayed neutron fraction βeff, and the mean generation time λ for code validation efforts. At higher detection rates, i.e. above 2×104 cps in the used configuration at 0.1 W, the previously employed pulse charge amplification electronics with BF3 detectors yielded erroneous results due to dead time effects. Future experimental needs call for higher sensitivity in detectors, higher detection rates or higher reactor powers, and thus a generally more versatile measurement system. We, therefore, explored detectors operated with current mode acquisition electronics to accommodate the need. We approached the matter in two ways: 1) By using the two compensated 10B-coated ionization chambers available in CROCUS as operational monitors. The compensated current signal of these chambers was extracted from coremonitoring output channels. 2) By developing a new current mode amplification station to be used with other available detectors in core. Characteristics and first noise measurements of the new current system are presented. We implemented post-processing of the current signals from 1)and 2) with the APSD/CPSD method to determine α. At two critical states (0.5 and 1.5 W), using the 10B ionization chambers and their CPSD estimate, the prompt decay constant was measured after 1.5 hours to be α=(156.9 ± 4.3) s-1 (1σ). This result is within 1σ of statistical uncertainties of previous experiments and MCNPv5-1.6 predictions using the ENDF/B-7.1 library. The newsystem connected to a CFUL01 fission chamber using the APSDestimate at 100 mW after 33 min yielded α = (160.8 ± 6.3) s-1, also within 1σ agreement. The improvements to previous neutron noise

  15. Study on current limiting characteristics of SFCL with two trigger current levels

    International Nuclear Information System (INIS)

    Lim, S.H.

    2010-01-01

    In this paper, the superconducting fault current limiter (SFCL) with two trigger current levels was suggested and its effectiveness through the analysis on the current limiting characteristics was described. The proposed SFCL, which consists of the triggering and the limiting components, can limit the fault current by generating the limiting impedance through two steps according to the amplitude of the initial fault current. In case that the fault happens, the lower initial fault current causes the only superconducting element of the triggering component to be quenched. On the other hand, the higher initial fault current makes both the superconducting elements comprising the triggering and the limiting components of the SFCL to be quenched, which contributes to the higher impedance of the SFCL. Therefore, the effective fault current limiting operation of the SFCL can be performed by generating the SFCL's impedance in proportion to the amplitude of the initial fault current. To confirm the current limiting operation of the proposed SFCL, the short-circuit tests of the SFCL according to the fault angle were carried out and its effective fault current limiting operations could be discussed.

  16. Charge Exchange Contribution to the Decay of the Ring Current, Measured by Energetic Neutral Atoms (ENAs)

    Science.gov (United States)

    Jorgensen, A. M.; Henderson, M. G.; Roelof, E. C.; Reeves, G. D.; Spence, H. E.

    2001-01-01

    In this paper we calculate the contribution of charge exchange to the decay of the ring current. Past works have suggested that charge exchange of ring current protons is primarily responsible for the decay of the ring current during the late recovery phase, but there is still much debate about the fast decay of the early recovery phase. We use energetic neutral atom (ENA) measurements from Polar to calculate the total ENA energy escape. To get the total ENA escape we apply a forward modeling technique, and to estimate the total ring current energy escape we use the Dessler-Parker-Sckopke relationship. We find that during the late recovery phase of the March 10, 1998 storm ENAs with energies greater than 17.5 keV can account for 75% of the estimated energy loss from the ring current. During the fast recovery the measured ENAs can only account for a small portion of the total energy loss. We also find that the lifetime of the trapped ions is significantly shorter during the fast recovery phase than during the late recovery phase, suggesting that different processes are operating during the two phases.

  17. Measurement of the Muon Neutrino Inclusive Charged Current Cross Section on Iron using the MINOS Detector

    Energy Technology Data Exchange (ETDEWEB)

    Loiacono, Laura Jean [Univ. of Texas, Austin, TX (United States)

    2010-05-01

    The Neutrinos at the Main Injector (NuMI) facility at Fermi National Accelerator Laboratory (FNAL) produces an intense muon neutrino beam used by the Main Injector Neutrino Oscillation Search (MINOS), a neutrino oscillation experiment, and the Main INjector ExpeRiment v-A, (MINERv A), a neutrino interaction experiment. Absolute neutrino cross sections are determined via σv = N vv , where the numerator is the measured number of neutrino interactions in the MINOS Detector and the denominator is the flux of incident neutrinos. Many past neutrino experiments have measured relative cross sections due to a lack of precise measurements of the incident neutrino flux, normalizing to better established reaction processes, such as quasielastic neutrino-nucleon scattering. But recent measurements of neutrino interactions on nuclear targets have brought to light questions about our understanding of nuclear effects in neutrino interactions. In this thesis the vμ inclusive charged current cross section on iron is measured using the MINOS Detector. The MINOS detector consists of alternating planes of steel and scintillator. The MINOS detector is optimized to measure muons produced in charged current vμ interactions. Along with muons, these interactions produce hadronic showers. The neutrino energy is measured from the total energy the particles deposit in the detector. The incident neutrino flux is measured using the muons produced alongside the neutrinos in meson decay. Three ionization chamber monitors located in the downstream portion of the NuMI beamline are used to measure the muon flux and thereby infer the neutrino flux by relation to the underlying pion and kaon meson flux. This thesis describes the muon flux instrumentation in the NuMI beam, its operation over the two year duration of this measurement, and the techniques used to derive the neutrino flux.

  18. Analysis of strain distribution and critical current of superconductors based on a strain-critical current measurement system

    International Nuclear Information System (INIS)

    Liu Fang; Wu Yu; Long Feng

    2010-01-01

    Based on Pacman device which is widely used to investigate the axial strain dependence of the critical current in superconductors, the finite element analysis method is employed to carry out the force analysis of the spring and the superconducting strand, thereby the axial and lateral strain distributions of the superconducting strand are obtained. According to the two extreme assumptions(low inter-filament resistance and high inter-filament resistance), the effects of the strain homogeneity at the cross section of the superconductor on the critical current is analyzed combined with the Nb 3 Sn deviatoric strain-critical current scaling law. (authors)

  19. Edge effects in four-point direct current potential drop measurements on metal plates

    International Nuclear Information System (INIS)

    Lu, Y; Bowler, N; Bowler, J R; Huang, Y

    2009-01-01

    Four-point direct current potential drop (DCPD) measurements are commonly used to measure the conductivity (or resistivity) of semiconductors and ferrous or non-ferrous metals. The measured electrical potential difference is often interpreted in terms of analytic expressions developed for large plates that are either 'thin' or 'thick' relative to the probe length. It is well known that the presence of the back surface of a plate leads to a solution expressed in terms of an infinite series representing the current source and its images. This approach can be generalized to account for multiple surfaces in order to obtain a solution for a finite plate, but convergence of the series is poor when the plate dimensions are similar to or smaller than the separation of the current injection and extraction points. Here, Fourier series representations of the infinite sums are obtained. It is shown that the Fourier series converge with many fewer terms than the series obtained from image theory, for plates with dimensions similar to or smaller than the separation of the current injection and extraction points. Comparing calculated results for the potential drop obtained by a four-point probe centred on finite plates of varying dimension, with those for a probe in contact with a large (laterally infinite) plate, estimates are given of the uncertainty due to edge effects in measurements on small plates interpreted using analytic formulae developed for large plates. It is also shown that these uncertainties due to edge effects are reduced, for a given plate size, if the probe pick-up points are moved closer to the current injection points, rather than adopting the common arrangement in which the four probe points are equally spaced. Calculated values of DCPD are compared with experimental data taken on aluminium and spring-steel plates of various sizes and excellent agreement is obtained.

  20. Edge effects in four-point direct current potential drop measurements on metal plates

    Science.gov (United States)

    Lu, Y.; Bowler, N.; Bowler, J. R.; Huang, Y.

    2009-07-01

    Four-point direct current potential drop (DCPD) measurements are commonly used to measure the conductivity (or resistivity) of semiconductors and ferrous or non-ferrous metals. The measured electrical potential difference is often interpreted in terms of analytic expressions developed for large plates that are either 'thin' or 'thick' relative to the probe length. It is well known that the presence of the back surface of a plate leads to a solution expressed in terms of an infinite series representing the current source and its images. This approach can be generalized to account for multiple surfaces in order to obtain a solution for a finite plate, but convergence of the series is poor when the plate dimensions are similar to or smaller than the separation of the current injection and extraction points. Here, Fourier series representations of the infinite sums are obtained. It is shown that the Fourier series converge with many fewer terms than the series obtained from image theory, for plates with dimensions similar to or smaller than the separation of the current injection and extraction points. Comparing calculated results for the potential drop obtained by a four-point probe centred on finite plates of varying dimension, with those for a probe in contact with a large (laterally infinite) plate, estimates are given of the uncertainty due to edge effects in measurements on small plates interpreted using analytic formulae developed for large plates. It is also shown that these uncertainties due to edge effects are reduced, for a given plate size, if the probe pick-up points are moved closer to the current injection points, rather than adopting the common arrangement in which the four probe points are equally spaced. Calculated values of DCPD are compared with experimental data taken on aluminium and spring-steel plates of various sizes and excellent agreement is obtained.

  1. Simplified tools for measuring retention in care in antiretroviral treatment program in Ethiopia: cohort and current retention in care.

    Science.gov (United States)

    Assefa, Yibeltal; Worku, Alemayehu; Wouters, Edwin; Koole, Olivier; Haile Mariam, Damen; Van Damme, Wim

    2012-01-01

    Patient retention in care is a critical challenge for antiretroviral treatment programs. This is mainly because retention in care is related to adherence to treatment and patient survival. It is therefore imperative that health facilities and programs measure patient retention in care. However, the currently available tools, such as Kaplan Meier, for measuring retention in care have a lot of practical limitations. The objective of this study was to develop simplified tools for measuring retention in care. Retrospective cohort data were collected from patient registers in nine health facilities in Ethiopia. Retention in care was the primary outcome for the study. Tools were developed to measure "current retention" in care during a specific period of time for a specific "ART-age group" and "cohort retention" in care among patients who were followed for the last "Y" number of years on ART. "Probability of retention" based on the tool for "cohort retention" in care was compared with "probability of retention" based on Kaplan Meier. We found that the new tools enable to measure "current retention" and "cohort retention" in care. We also found that the tools were easy to use and did not require advanced statistical skills. Both "current retention" and "cohort retention" are lower among patients in the first two "ART-age groups" and "ART-age cohorts" than in subsequent "ART-age groups" and "ART-age cohorts". The "probability of retention" based on the new tools were found to be similar to the "probability of retention" based on Kaplan Meier. The simplified tools for "current retention" and "cohort retention" will enable practitioners and program managers to measure and monitor rates of retention in care easily and appropriately. We therefore recommend that health facilities and programs start to use these tools in their efforts to improve retention in care and patient outcomes.

  2. Simplified tools for measuring retention in care in antiretroviral treatment program in Ethiopia: cohort and current retention in care.

    Directory of Open Access Journals (Sweden)

    Yibeltal Assefa

    Full Text Available INTRODUCTION: Patient retention in care is a critical challenge for antiretroviral treatment programs. This is mainly because retention in care is related to adherence to treatment and patient survival. It is therefore imperative that health facilities and programs measure patient retention in care. However, the currently available tools, such as Kaplan Meier, for measuring retention in care have a lot of practical limitations. The objective of this study was to develop simplified tools for measuring retention in care. METHODS: Retrospective cohort data were collected from patient registers in nine health facilities in Ethiopia. Retention in care was the primary outcome for the study. Tools were developed to measure "current retention" in care during a specific period of time for a specific "ART-age group" and "cohort retention" in care among patients who were followed for the last "Y" number of years on ART. "Probability of retention" based on the tool for "cohort retention" in care was compared with "probability of retention" based on Kaplan Meier. RESULTS: We found that the new tools enable to measure "current retention" and "cohort retention" in care. We also found that the tools were easy to use and did not require advanced statistical skills. Both "current retention" and "cohort retention" are lower among patients in the first two "ART-age groups" and "ART-age cohorts" than in subsequent "ART-age groups" and "ART-age cohorts". The "probability of retention" based on the new tools were found to be similar to the "probability of retention" based on Kaplan Meier. CONCLUSION: The simplified tools for "current retention" and "cohort retention" will enable practitioners and program managers to measure and monitor rates of retention in care easily and appropriately. We therefore recommend that health facilities and programs start to use these tools in their efforts to improve retention in care and patient outcomes.

  3. Studies of non-inductive current drive in the CDX-U tokamak

    International Nuclear Information System (INIS)

    Hwang, Y.S.

    1993-01-01

    Two types of novel, non-inductive current drive concepts for starting-up and maintaining tokamak discharges, dc-helicity injection and internally-generated pressure-driven currents, have been developed on the CDX-U tokamak. To study the equilibrium and transport of these plasmas, a full set of magnetic diagnostics was installed. By applying a finite element method and a least squares error fitting technique, internal plasma current distributions are reconstructed from the measurements. Electron density distributions were obtained from 2 mm interferometer measurements by a similar least squares error technique utilizing magnetic flux configurations obtained by the magnetic analysis. Neoclassical pressure-driven currents in ECH plasmas are modeled with the reconstructed magnetic structure, using the electron density distribution and the electron temperature profile measured by a Langmuir probe. In the dc-helicity injection scheme, the need to increase injection current and maintain plasma equilibrium restricts possible arrangements. Several injection configurations were investigated, with the best found to be outside injection with a single divertor configuration, where the cathode is placed at the low field side of the x-point. Both pressure-driven and dc-helicity injected tokamaks show the importance of plasma equilibrium in obtaining high plasma current. Programmed vertical field operation has proven to be very important in achieving high plasma current. These non-inductive current drive techniques show great potential as efficient current drive methods for future steady-state and/or long-pulse fusion reactors

  4. Critical current density measurement of thin films by AC susceptibility based on the penetration parameter h

    DEFF Research Database (Denmark)

    Li, Xiao-Fen; Grivel, Jean-Claude; Abrahamsen, Asger B.

    2012-01-01

    We have numerically proved that the dependence of AC susceptibility χ of a E(J) power law superconducting thin disc on many parameters can be reduced to one penetration parameter h, with E the electric field and J the current density. Based on this result, we propose a way of measuring the critical...... current density Jc of superconducting thin films by AC susceptibility. Compared with the normally used method based on the peak of the imaginary part, our method uses a much larger range of the AC susceptibility curve, thus allowing determination of the temperature (T) dependence of Jc from a normally...

  5. Automated Studies of Continuing Current in Lightning Flashes

    Science.gov (United States)

    Martinez-Claros, Jose

    Continuing current (CC) is a continuous luminosity in the lightning channel that lasts longer than 10 ms following a lightning return stroke to ground. Lightning flashes following CC are associated with direct damage to power lines and are thought to be responsible for causing lightning-induced forest fires. The development of an algorithm that automates continuing current detection by combining NLDN (National Lightning Detection Network) and LEFA (Langmuir Electric Field Array) datasets for CG flashes will be discussed. The algorithm was applied to thousands of cloud-to-ground (CG) flashes within 40 km of Langmuir Lab, New Mexico measured during the 2013 monsoon season. It counts the number of flashes in a single minute of data and the number of return strokes of an individual lightning flash; records the time and location of each return stroke; performs peak analysis on E-field data, and uses the slope of interstroke interval (ISI) E-field data fits to recognize whether continuing current (CC) exists within the interval. Following CC detection, duration and magnitude are measured. The longest observed C in 5588 flashes was 631 ms. The performance of the algorithm (vs. human judgement) was checked on 100 flashes. At best, the reported algorithm is "correct" 80% of the time, where correct means that multiple stations agree with each other and with a human on both the presence and duration of CC. Of the 100 flashes that were validated against human judgement, 62% were hybrid. Automated analysis detects the first but misses the second return stroke in many cases where the second return stroke is followed by long CC. This problem is also present in human interpretation of field change records.

  6. Fast measure proceeding of weak currents; Un procede de mesure rapide des courants faibles

    Energy Technology Data Exchange (ETDEWEB)

    Taieb, J [Commissariat a l' Energie Atomique, Siege (France). Centre d' Etudes Nucleaires

    1953-07-01

    The process of fast measure of the weak currents that we are going to describe briefly apply worthy of the provided currents by the sources to elevated value internal resistance, as it is the case for the ionization chamber, the photocells, mass spectroscopic tubes. The problem to measure weak currents is essentially a problem of amplifier and of input circuit. We intended to achieve a whole amplifier and input circuit with advanced performances, meaning that for a measured celerity we wanted to have an signal/noise ratio the most important as in the classic systems and for a same report signal/noise a more quickly done measure. (M.B.) [French] Le procede de mesure rapide des courants faibles que nous allons brievement decrire s'applique a la mesure des courants fournis par les sources a resistance interne de valeur elevee, comme c'est le cas pour les chambres d'ionisation, les photocellules, les tubes de spectrographe de masse. Le probleme de mesure de courants faibles est essentiellement un probleme d'amplificateur et de circuit d'entree. Nous nous sommes proposes de realiser un ensemble amplificateur et circuit d'entree a performances poussees, c'est a dire que pour une meme rapidite de mesure nous desirions avoir un rapport signal/bruit plus important que dans les systemes classiques et pour un meme rapport signal/bruit une mesure effectuee plus rapidement. (M.B.)

  7. Study of noninductive current generation in a plasma

    International Nuclear Information System (INIS)

    Rax, J.M.

    1987-01-01

    Three aspects of noninductive current generation are treated: (1) The kinetic problem, i.e., coupling between current-carrying energetic electrons on the one hand, and the electromagnetic wave and thermal particles on the other. (2). The electromagnetic problem, i.e., calculation of the wave structure produced by the antennas. (3) The study of nonthermal radiation and electrical responses. Green's functions are used to solve the kinetic problem. The electron distribution function is calculated. For the electromagnetic problem of wave structure at different wave numbers, the Green's function of the Maxwell equations in an inhomogeneous, anisotropic medium which is spatially and temporally scattered was calculated. Perturbation of propagation by diffusion and conversion was studied. The calculation of nonthermal radiation and of transfer of electromagnetic wave energy into magnetic energy is derived from the two preceding problems. A method to produce fusion power quasi-continuously using two inductively and thermally coupled tokamaks is proposed [fr

  8. A Long-term Ring Current Measure Created by Using the VMO MANGO Service Package

    Science.gov (United States)

    Bargatze, L. F.; King, T. A.

    2008-12-01

    A set of computational routines called MANGO (Magnetogram Analysis for the Network of Geomagnetic Observatories) is utilized to calculate a new measure of magnetic storm activity for the years 1932 to the near present. The MANGO routines are part of an effort to enhance data services available to users of the Heliophysics VxOs, specifically for the Virtual Magnetospheric Observatory (VMO). The community can utilize MANGO to derive value-added data products and images suitable for publication via the VMO web site. MANGO routines will be demonstrated through their application to study magnetic storms, a field of research that began in 1828 when von Humboldt launched an investigation of observations taken simultaneously from magnetic field stations spread around the Earth. The defining signature of magnetic storms is a worldwide decrease of the horizontal component of the magnetic field caused by fluctuations in the strength of the ring current. In the 1940's, Bartel pushed for deriving an index to measure the strength of magnetic storms. Progress intensified during the International Geophysical Year leading to the definition of the Dst index. The definitive Dst index is calculated at WDC-C2 for Geomagnetism in Kyoto by using a derivation scheme certified by Division V of IAGA. The Dst index time series spans the years 1957 to present with a cadence equal to 1-hr. The new data set we will present is a magnetic storm measure that is similar to the Dst index though it is calculated by using MANGO and a method that differs slightly from the official scheme. The MANGO data service package is based on a set of IDL routines that decompose ground magnetic field observations to isolate secular, diurnal, and disturbance variations of the magnetic field station-by-station. Each MANGO subroutine has been written in modular fashion to allow "plug and play"- style flexibility and each has been designed to account for failure modes and noisy data so that the programs will run to

  9. Study and Evaluation of Current and Future Aircraft Loaders

    Science.gov (United States)

    1986-08-01

    detonation intense Electromagnetic Pulse Eergy (DIP) is gene - rated which could seriously affect the electronic equipment. 2-105 The intense...speciality efforts, such as integrated logistics support (ILS), human factors engineering ( HFE ), and reliability, availability and m aintainability...task analyiis is outlined in detail in Appendix C: Human Fac- tors Enqineering Study and Evaluation of Current and Future Aircraft Loaders. The HFE

  10. AUTOMATED MEASURING COMPLEX FOR ACCEPTANCE TESTING OF DC AND UNDULATED-CURRENT TRACTION MOTORS

    Directory of Open Access Journals (Sweden)

    A. Yu. Drubetskyi

    2016-12-01

    transducers for the measurement of currents and voltages. Thanks to chassis compact size, it was united in one body with the power supply for sensors. Thus, it was possible to reduce the size of the entire complex, simplify and speed up its preparations for the measurements.

  11. Study on pulsed current cathodic protection in a simulated system

    Energy Technology Data Exchange (ETDEWEB)

    Yan, Milin; Li, Helin [Xi' an Jiao Tong Universitiy (China)]|[Tubular Goods Research Center of China National Petroleum Corp. (China); Qiu, Yubing; Guo, Xingpeng [Hua Zhong University of Science and Techonology (China)

    2004-07-01

    The pulsed current cathodic protection (PCCP) is a new cathodic protection (CP) technology and shows more advantages over the conventional DC cathodic protection (DCCP) in oil well casing system. However, little information about PCCP is reported. In this research, a simulated CP system was set up in a pool of 3.5 m x 2.0 m x 3.0 m size, in which the effects of the square wave pulsed current (SWPC) parameters (amplitude: IA, frequency: f, duty cycle: P), auxiliary anode distance (d) and media conductivity ({mu}) on the cathodic potential (E) distribution were studied, and the protection effects of PCCP and DCCP were compared. The results show that with increase of the square wave parameters (IA, f, P), the E distribution becomes more negative and the effects of each current parameter are relate closely to the cathode polarizing state. Only with suitable square wave parameters can the whole cathode be effectively protected. With increase of d and {mu}, the E distribution becomes more uniform. Compared with DCCP system, PCCP system has much more uniform E distribution, costs less average current, and gains much better protection effects. Further, the mechanism of PCCP was analyzed. (authors)

  12. Field Measurements at River and Tidal Current Sites for Hydrokinetic Energy Development: Best Practices Manual

    Energy Technology Data Exchange (ETDEWEB)

    Neary, Vincent S [ORNL; Gunawan, Budi [Oak Ridge National Laboratory (ORNL)

    2011-09-01

    In this report, existing data collection techniques and protocols for characterizing open channel flows are reviewed and refined to further address the needs of the MHK industry. The report provides an overview of the hydrodynamics of river and tidal channels, and the working principles of modern acoustic instrumentation, including best practices in remote sensing methods that can be applied to hydrokinetic energy site characterization. Emphasis is placed upon acoustic Doppler velocimeter (ADV) and acoustic-Doppler current profiler (ADCP) instruments, as these represent the most practical and economical tools for use in the MHK industry. Incorporating the best practices as found in the literature, including the parameters to be measured, the instruments to be deployed, the instrument deployment strategy, and data post-processing techniques. The data collected from this procedure aims to inform the hydro-mechanical design of MHK systems with respect to energy generation and structural loading, as well as provide reference hydrodynamics for environmental impact studies. The standard metrics and protocols defined herein can be utilized to guide field experiments with MHK systems.

  13. Current situation and control measures of groundwater pollution in gas station

    Science.gov (United States)

    Wu, Qiong; Zhang, Xiaofeng; Zhang, Qianjin

    2017-11-01

    In recent years, pollution accidents caused by gas station leakage has occurred worldwide which can be persistent in groundwater. Numerous studies have demonstrated that the contaminated groundwater is threatening the ecological environment and human health. In this article, current status and sources of groundwater pollution by gas station are analyzed, and experience of how to prevent groundwater pollution from gas stations are summarized. It is demonstrated that installation of secondary containment measures for the oil storage of the oil tank system, such as installation of double-layer oil tanks or construction of impermeable ponds, is a preferable method to prevent gas stations from groundwater pollution. Regarding to the problems of groundwater pollution caused by gas station, it is proposed that it is urgent to investigate the leakage status of gas station. Relevant precise implementation regulations shall be issued and carried out, and supervision management of gas stations would need to be strengthened. Then single-layer steel oil tanks shall be replaced by double-layer tanks, and the impermeable ponds should be constructed according to the risk ranking. From the control methodology, the groundwater environment monitoring systems, supervision level, laws and regulations as well as pollution remediation should also be carried out and strengthened.

  14. [Current state of measures to deal with natural disasters at public universities].

    Science.gov (United States)

    Hirouchi, Tomoko; Tanka, Mamoru; Shimada, Ikuko; Yoshimoto, Yoshinobu; Sato, Atsushi

    2012-03-01

    The responsibility of a university after a large-scale, natural disaster is to secure the safety of students' and local residents' lives. The present study investigated the current state of measures at public universities to deal with natural disasters in coordination with the local community. A survey was administered at 77 public universities in Japan from March 25 to May 10, 2011. The survey included questions on the existence of local disaster evacuation sites, a disaster manual, disaster equipment storage, emergency drinking water, and food storage. A total of 51% of universities had designated local evacuation sites. Based on responses for the remaining questions, universities with and without the designated disaster response solutions accounted for 42% and 57%, respectively, for disaster manuals; 55% and 33%, respectively, for disaster equipment; 32% and 13%, respectively, for disaster drinking water storage; and 26% and 7%, respectively, for emergency food storage. A majority of public universities have not created disaster manuals, regardless of whether they have a local evacuation site. The survey results also indicated that most universities have no storage of disaster equipment or emergency supplies.

  15. Measurements of charged- and neutral-current cross sections by the CFRR collaboration

    International Nuclear Information System (INIS)

    Blair, R.; Barish, B.; Chu, Y.

    1981-07-01

    We present results on normalized charged and neutral current cross sections. The charged current results can be parameterized by a linearly rising cross section with sigma/sub ν//E = 0.719 +- 0.006 +- 0.036 x 10 -38 cm 2 /GeV and sigma/sub ν/-/E = 0.371 +- 0.004 +- 0.019 x 10 -38 cm 2 /GeV. These results are approx. 15% higher than previous measurements. Preliminary structure functions at low Q 2 are also presented. The neutral current was analyzed using the Paschos-Wolfenstein technique and yields sin 2 sigma/sub w/ = 0.243 +- 0.016

  16. Measuring ac losses in superconducting cables using a resonant circuit:Resonant current experiment (RESCUE)

    DEFF Research Database (Denmark)

    Däumling, Manfred; Olsen, Søren Krüger; Rasmussen, Carsten

    1998-01-01

    be recorded using, for example, a digital oscilloscope. The amplitude decay of the periodic voltage or current accurately reflects the power loss in the system. It consists of two components-an ohmic purely exponential one (from leads, contacts, etc.), and a nonexponential component originating from......A simple way to obtain true ac losses with a resonant circuit containing a superconductor, using the decay of the circuit current, is described. For the measurement a capacitor is short circuited with a superconducting cable. Energy in the circuit is provided by either charging up the capacitors...... with a certain voltage, or letting a de flow in the superconductor. When the oscillations are started-either by opening a switch in case a de is flowing or by closing a switch to connect the charged capacitors with the superconductor-the current (via a Rogowski coil) or the voltage on the capacitor can...

  17. Analyses on the measurement of leakage currents in CdZnTe radiation detectors

    International Nuclear Information System (INIS)

    Mescher, M.J.; Hoburg, J.F.; Schlesinger, T.E.; James, R.B.

    1999-01-01

    Models that place design constraints on devices which are used to measure the leakage currents in high-resistivity semiconductor materials are presented. If these design constraints are met, these models can then be used to quantitatively predict the surface sheet resistance of devices which are dominated by surface leakage currents. As a result, a means is provided to directly compare passivation techniques which are developed to decrease surface leakage currents. Furthermore, these models illustrate the necessity for inclusion of relevant geometrical data on sample size and shape and electrode configuration when reporting results of surface passivation techniques. These models specifically examine the case where a dc potential is applied across two electrodes on the surface of a semiconductor substrate which has a surface layer with lower resistivity than the bulk material. The authors describe several of the more common configurations used in analyzing passivation techniques for compounds of Cd 1-x Zn x Te (CZT) used for room-temperature radiation detection

  18. Development of system for automatic measurement of transient photocurrent and thermally stimulated current

    Directory of Open Access Journals (Sweden)

    Asdrubal Antonio Ramirez Botero

    2017-01-01

    Full Text Available This paper presents details of the design and implementation of a system for measuring of thermally stimulated current (TSC and transient photocurrent (Iph, developed using the Virtual Instrumentation concept. For that we have used National Instrument hardware and the LabView® package as software. The system is controlled by a virtual instrument (VI which includes facilities to perform measurements of photocurrent keeping the temperature of the sample and the pressure of the chamber of measurement controlled as well as  real time display of the Iph vs t and TSC vs T curves. The system was tested by performing transient photocurrent and TSC measurements on CH3NH3PbI3 thin films that are generally used as absorbent layer of solar cells. This type of characterization is very useful to get information of the  trapping and recombination processes that affect the transport properties of the devices.

  19. Charge Transport in Spiro-OMeTAD Investigated through Space-Charge-Limited Current Measurements

    Science.gov (United States)

    Röhr, Jason A.; Shi, Xingyuan; Haque, Saif A.; Kirchartz, Thomas; Nelson, Jenny

    2018-04-01

    Extracting charge-carrier mobilities for organic semiconductors from space-charge-limited conduction measurements is complicated in practice by nonideal factors such as trapping in defects and injection barriers. Here, we show that by allowing the bandlike charge-carrier mobility, trap characteristics, injection barrier heights, and the shunt resistance to vary in a multiple-trapping drift-diffusion model, a numerical fit can be obtained to the entire current density-voltage curve from experimental space-charge-limited current measurements on both symmetric and asymmetric 2 ,2',7 ,7' -tetrakis(N ,N -di-4-methoxyphenylamine)-9 ,9' -spirobifluorene (spiro-OMeTAD) single-carrier devices. This approach yields a bandlike mobility that is more than an order of magnitude higher than the effective mobility obtained using analytical approximations, such as the Mott-Gurney law and the moving-electrode equation. It is also shown that where these analytical approximations require a temperature-dependent effective mobility to achieve fits, the numerical model can yield a temperature-, electric-field-, and charge-carrier-density-independent mobility. Finally, we present an analytical model describing trap-limited current flow through a semiconductor in a symmetric single-carrier device. We compare the obtained charge-carrier mobility and trap characteristics from this analytical model to the results from the numerical model, showing excellent agreement. This work shows the importance of accounting for traps and injection barriers explicitly when analyzing current density-voltage curves from space-charge-limited current measurements.

  20. Collectivism and coping: current theories, evidence, and measurements of collective coping.

    Science.gov (United States)

    Kuo, Ben C H

    2013-01-01

    A burgeoning body of cultural coping research has begun to identify the prevalence and the functional importance of collective coping behaviors among culturally diverse populations in North America and internationally. These emerging findings are highly significant as they evidence culture's impacts on the stress-coping process via collectivistic values and orientation. They provide a critical counterpoint to the prevailing Western, individualistic stress and coping paradigm. However, current research and understanding about collective coping appear to be piecemeal and not well integrated. To address this issue, this review attempts to comprehensively survey, summarize, and evaluate existing research related to collective coping and its implications for coping research with culturally diverse populations from multiple domains. Specifically, this paper reviews relevant research and knowledge on collective coping in terms of: (a) operational definitions; (b) theories; (c) empirical evidence based on studies of specific cultural groups and broad cultural values/dimensions; (d) measurements; and (e) implications for future cultural coping research. Overall, collective coping behaviors are conceived as a product of the communal/relational norms and values of a cultural group across studies. They also encompass a wide array of stress responses ranging from value-driven to interpersonally based to culturally conditioned emotional/cognitive to religion- and spirituality-grounded coping strategies. In addition, this review highlights: (a) the relevance and the potential of cultural coping theories to guide future collective coping research; (b) growing evidence for the prominence of collective coping behaviors particularly among Asian nationals, Asian Americans/Canadians and African Americans/Canadians; (c) preference for collective coping behaviors as a function of collectivism and interdependent cultural value and orientation; and (d) six cultural coping scales. This

  1. Experimental measurements of the eddy current signal due to a flawed, conducting half space

    International Nuclear Information System (INIS)

    Long, S.A.; Toomsawasdi, S.; Zaman, A.J.M.

    1984-01-01

    This chapter reports on an experimental investigation in which the change in impedance of a practical multi-turn eddy current coil near a conducting half space is measured as a function of the conductivity and the lift-off distance. The results are compared in a qualitative fashion with the analytical results for a single-turn coil. Measurements are also made of the change in impedance due to a small void in the conducting half space as a function of both its depth and radial position. The results indicate that, at least in a qualitative fashion, the precisely derived analytical solutions adequately predict the general behavior of the change in complex impedance of an eddy current coil above a conducting ground plane as a function of lift-off distance. It is determined that the effect of a sub-surface void on the change in inductance of the test coil correlates well with theoretical calculations

  2. First Measurement of the Muon Neutrino Charged Current Quasielastic Double Differential Cross Section

    Energy Technology Data Exchange (ETDEWEB)

    Aguilar-Arevalo, A.A.; /Mexico U., CEN; Anderson, C.E.; /Yale U.; Bazarko, A.O.; /Princeton U.; Brice, S.J.; /Fermilab; Brown, B.C.; /Fermilab; Bugel, L.; /Columbia U.; Cao, J.; /Michigan U.; Coney, L.; /Columbia U.; Conrad, J.M.; /MIT; Cox, D.C.; /Indiana U.; Curioni, A.; /Yale U. /Columbia U.

    2010-02-01

    A high-statistics sample of charged-current muon neutrino scattering events collected with the MiniBooNE experiment is analyzed to extract the first measurement of the double differential cross section (d{sup 2}{sigma}/dT{sub {mu}}d cos {theta}{sub {mu}}) for charged-current quasielastic (CCQE) scattering on carbon. This result features minimal model dependence and provides the most complete information on this process to date. With the assumption of CCQE scattering, the absolute cross section as a function of neutrino energy ({sigma}[E{sub {nu}}]) and the single differential cross section (d{sigma}/dQ{sup 2}) are extracted to facilitate comparison with previous measurements. These quantities may be used to characterize an effective axial-vector form factor of the nucleon and to improve the modeling of low-energy neutrino interactions on nuclear targets. The results are relevant for experiments searching for neutrino oscillations.

  3. Drift chamber electronics with multi-hit capability for time and current division measurements

    Energy Technology Data Exchange (ETDEWEB)

    Manarin, A; Pregernig, L; Rabany, M; Saban, R; Vismara, G

    1983-11-15

    Drift chambers have been installed for luminosity measurements in intersection 5 of the SPS accelerator working in panti p colliding mode. The required electronics is described. The system is able to process up to 16 hits per wire with a double pulse resolution of 40 ns; drift time and current division, with 1.25 ns and 1.6% resolution respectively, are recorded. Transconductance preamplifiers and discriminators are directly mounted on the chamber; 160 m of twisted-apir cable bring the signals to the digitizer unit. Coarse time is measured using RAM techniques, while fine time is obtained by means of a microstrip delay associated with a 100 K ECL priority encoder. Current division used a single 50 MHz Flash ADC which alows 26 dB dynamic range with 6 bit resolution. First operational results are reported.

  4. Development of an Optical Sensor Head for Current and Temperature Measurements in Power Systems

    Directory of Open Access Journals (Sweden)

    Fábio V. B. de Nazaré

    2013-01-01

    Full Text Available The development of a current and temperature monitoring optical device intended to be used in high-voltage environments, particularly transmission lines, is presented. The system is intended to offer not only measurement reliability, but to be also practical and light weighted. Fiber Bragg gratings (FBGs are employed in the measurement of both physical parameters: the current will be acquired using a hybrid sensor head setup—an FBG fixed on a magnetostrictive rod—while a single-point temperature information is provided by a dedicated grating. An inexpensive and outdoor-suitable demodulation method, such as the fixed filter technique, should be used in order to improve the instrumentation robustness, avoiding expensive and complex auxiliary electronics. The preliminary results for laboratory tests are also discussed.

  5. Current and capacitance measurements as a fast diagnostic tool for evaluation of semiconductor parameters

    CERN Document Server

    Kemmer, J; Krause, N; Krieglmeyer, C; Yang Yi

    2000-01-01

    A fast qualitative method is described for evaluation of semiconductor parameters by analyzing both the capacitance/voltage (C/V) and current/voltage (I/V) characteristics of pn- or Schottky-diodes, which are fabricated on the material under investigation. The method is applied for measurement of recombination and generation lifetimes of minority charge carriers and for determination of doping profiles and distribution of active generation/recombination (G/R) centers after irradiation with Am-alpha particles and deep phosphorus implantation. Measurements on epitaxial silicon result in doping profiles and distributions of active impurities within the epi-layer.

  6. Passive measurement of flux nucleation in the current-induced resistive state of type I superconductors

    International Nuclear Information System (INIS)

    Selig, K.P.; Chimenti, D.E.; Huebener, R.P.

    1978-01-01

    Flux-tube nucleation rates have been measured in the current-induced resistive state of type I superconducting In films between 1.5 and 2.0 K by a completely passive technique. Indication of periodic nucleation is observed only in narrow regions of sample voltage drop, whose position is a sensitive function of temperature. Frequency bandwidth measurements of the nucleation rate yield a spectral purity of one part in 10 4 within the narrow regions where an experimental signal can be detected. (orig.) [de

  7. The effect of different solar simulators on the measurement of short-circuit current temperature coefficients

    Science.gov (United States)

    Curtis, H. B.; Hart, R. E., Jr.

    1982-01-01

    Gallium arsenide solar cells are considered for several high temperature missions in space. Both near-Sun and concentrator missions could involve cell temperatures on the order of 200 C. Performance measurements of cells at elevated temperatures are usually made using simulated sunlight and a matched reference cell. Due to the change in bandgap with increasing temperature at portions of the spectrum where considerable simulated irradiance is present, there are significant differences in measured short circuit current at elevated temperatures among different simulators. To illustrate this, both experimental and theoretical data are presented for gallium arsenide cells.

  8. Variations in the electrical short-circuit current decay for recombination lifetime and velocity measurements

    Science.gov (United States)

    Jung, Tae-Won; Lindholm, Fredrik A.; Neugroschel, Arnost

    1987-01-01

    An improved measurement system for electrical short-circuit current decay is presented that extends applicability of the method to silicon solar cells having an effective lifetime as low as 1 microsec. The system uses metal/oxide/semiconductor transistors as voltage-controlled switches. Advances in theory developed here increase precision and sensitivity in the determination of the minority-carrier recombination lifetime and recombination velocity. A variation of the method, which exploits measurements made on related back-surface field and back-ohmic contact devices, further improves precision and sensitivity. The improvements are illustrated by application to 15 different silicon solar cells.

  9. IR Camera Validation of IGBT Junction Temperature Measurement via Peak Gate Current

    DEFF Research Database (Denmark)

    Baker, Nick; Dupont, Laurent; Munk-Nielsen, Stig

    2017-01-01

    partial bond-wire lift-off. Results are also compared with a traditional electrical temperature measurement method: the voltage drop under low current (VCE(low)). In all cases, the IGPeak method is found to provide a temperature slightly overestimating the temperature of the gate pad. Consequently, both...... the gate pad position and chip temperature distribution influence whether the measurement is representative of the mean junction temperature. These results remain consistent after chips are degraded through bondwire lift-off. In a paralleled IGBT configuration with non-negligible temperature disequilibrium...

  10. Validation of a Residual Stress Measurement Method by Swept High-Frequency Eddy Currents

    International Nuclear Information System (INIS)

    Lee, C.; Shen, Y.; Lo, C. C. H.; Nakagawa, N.

    2007-01-01

    This paper reports on a swept high-frequency eddy current (SHFEC) measurement method developed for electromagnetic nondestructive characterization of residual stresses in shot peened aerospace materials. In this approach, we regard shot-peened surfaces as modified surface layers of varying conductivity, and determine the conductivity deviation profile by inversion of the SHFEC data. The SHFEC measurement system consists of a pair of closely matched printed-circuit-board coils driven by laboratory instrument under software control. This provides improved sensitivity and high frequency performance compared to conventional coils, so that swept frequency EC measurements up to 50 MHz can be made to achieve the smallest skin depth of 80 μm for nickel-based superalloys. We devised a conductivity profile inversion procedure based on the laterally uniform multi-layer theory of Cheng, Dodd and Deeds. The main contribution of this paper is the methodology validation. Namely, the forward and inverse models were validated against measurements on artificial layer specimens consisting of metal films with different conductivities placed on a metallic substrate. The inversion determined the film conductivities which were found to agree with those measured using the direct current potential drop (DCPD) method

  11. Validation of a Residual Stress Measurement Method by Swept High-Frequency Eddy Currents

    Science.gov (United States)

    Lee, C.; Shen, Y.; Lo, C. C. H.; Nakagawa, N.

    2007-03-01

    This paper reports on a swept high-frequency eddy current (SHFEC) measurement method developed for electromagnetic nondestructive characterization of residual stresses in shot peened aerospace materials. In this approach, we regard shot-peened surfaces as modified surface layers of varying conductivity, and determine the conductivity deviation profile by inversion of the SHFEC data. The SHFEC measurement system consists of a pair of closely matched printed-circuit-board coils driven by laboratory instrument under software control. This provides improved sensitivity and high frequency performance compared to conventional coils, so that swept frequency EC measurements up to 50 MHz can be made to achieve the smallest skin depth of 80 μm for nickel-based superalloys. We devised a conductivity profile inversion procedure based on the laterally uniform multi-layer theory of Cheng, Dodd and Deeds. The main contribution of this paper is the methodology validation. Namely, the forward and inverse models were validated against measurements on artificial layer specimens consisting of metal films with different conductivities placed on a metallic substrate. The inversion determined the film conductivities which were found to agree with those measured using the direct current potential drop (DCPD) method.

  12. Model based optimization of driver-pickup separation for eddy current measurement of gap

    Science.gov (United States)

    Klein, G.; Morelli, J.; Krause, T. W.

    2018-04-01

    The fuel channels in CANDU® (CANada Deuterium Uranium) nuclear reactors consist of a pressure tube (PT) contained within a larger diameter calandria tube (CT). The separation between the tubes, known as the PT-CT gap, ensures PT hydride blisters, which could lead to potential cracking of the PT, do not develop. Therefore, accurate measurements are required to confirm that contact between PT and CT is not imminent. Gap measurement uses an eddy current probe. However this probe is sensitive to lift-off variations, which can adversely affect estimated gap. A validated analytical flat plate model of eddy current response to gap was used to examine the effect of driver-pickup spacing on lift-off and response to gap at a frequency of 4 kHz, which is used for in-reactor measurements. This model was compared against, and shown to have good agreement with, a COMSOL® finite element method (FEM) model. The optimum coil separation, which included the constraint of coil size, was found to be 11 mm, resulting in a phase response between lift-off and response to change in gap of 66°. This work demonstrates the advantages of using analytical models for optimizing coil designs for measurement of parameters that may negatively influence the outcome of an inspection measurement.

  13. Neutrino and antineutrino inclusive charged-current cross section measurement with the MINOS near detector

    International Nuclear Information System (INIS)

    Bhattacharya, Debdatta

    2009-01-01

    This thesis presents the measurement of energy dependence of the neutrino-nucleon inclusive charged current cross section on an isoscalar target in the range 3-50 GeV for neutrinos and 5-50 GeV energy range for antineutrinos. The data set was collected with the MINOS Near Detector using the wide band NuMI beam at Fermilab. The size of the charged current sample is 1.94 x 10 6 neutrino events and 1.60 x 10 5 antineutrino events. The flux has been extracted using a low hadronic energy sub-sample of the charged current events. The energy dependence of the cross section is obtained by dividing the charged current sample with the extracted flux. The neutrino and antineutrino cross section exhibits a linear dependence on energy at high energy but shows deviations from linear behavior at low energy. We also present a measurement of the ratio of antineutrino to neutrino inclusive cross section

  14. Neutrino and antineutrino inclusive charged-current cross section measurement with the MINOS near detector

    Energy Technology Data Exchange (ETDEWEB)

    Bhattacharya, Debdatta [Univ. of Pittsburgh, PA (United States)

    2009-01-01

    This thesis presents the measurement of energy dependence of the neutrino-nucleon inclusive charged current cross section on an isoscalar target in the range 3-50 GeV for neutrinos and 5-50 GeV energy range for antineutrinos. The data set was collected with the MINOS Near Detector using the wide band NuMI beam at Fermilab. The size of the charged current sample is 1.94 x 106 neutrino events and 1.60 x 105 antineutrino events. The flux has been extracted using a low hadronic energy sub-sample of the charged current events. The energy dependence of the cross section is obtained by dividing the charged current sample with the extracted flux. The neutrino and antineutrino cross section exhibits a linear dependence on energy at high energy but shows deviations from linear behavior at low energy. We also present a measurement of the ratio of antineutrino to neutrino inclusive cross section.

  15. Discharge current measurements on Venera 13 & 14 - Evidence for charged aerosols in the Venus lower atmosphere?

    Science.gov (United States)

    Lorenz, Ralph D.

    2018-06-01

    Measurements of discharge currents on the Venera 13 and 14 landers during their descent in the lowest 35 km of the Venus atmosphere are interpreted as driven either by an ambient electric field, or by deposition of charge from aerosols. The latter hypothesis is favored (`triboelectric charging' in aeronautical parlance), and would entail an aerosol opacity and charge density somewhat higher than that observed in Saharan dust transported over long distances on Earth.

  16. Neutron measurements in deuterated palladium cathodes subjected to pulsed electrolytic currents

    International Nuclear Information System (INIS)

    Granada, J.R.; Mayer, R.E.; Guido, G.; Florido, P.C.; Patino, N.E.; Gillette, V.H.; Sobehart, L.; Gomez, S.; Larreteguy, A.; Universidad Nacional de Cuyo, San Carlos de Bariloche

    1989-01-01

    We report on neutron measurements performed on electrolytic cells using a high efficiency (22%) detection system in combination with a procedure involving a non-stationary current through the cell's circuit. Under these conditions, neutron production was observed in cells containing LiH dissolved in heavy water with a Palladium cathode. Characteristic patterns showing one or two bumps were obtained in a repeatable fashion, depending on the previous charging history of the cathode. (orig.)

  17. Measurements of current density distribution in shaped e-beam writers

    Czech Academy of Sciences Publication Activity Database

    Bok, Jan; Horáček, Miroslav; Kolařík, Vladimír; Urbánek, Michal; Matějka, Milan; Krzyžánek, Vladislav

    2016-01-01

    Roč. 149, JAN 5 (2016), s. 117-124 ISSN 0167-9317 R&D Projects: GA ČR(CZ) GA14-20012S; GA MŠk(CZ) LO1212; GA MŠk ED0017/01/01 Institutional support: RVO:68081731 Keywords : shaped e-beam writer * electron beam * current density Subject RIV: JB - Sensors, Measurment, Regulation Impact factor: 1.806, year: 2016

  18. Eddy current proximity measurement of perpendicular tubes from within pressure tubes in CANDU nuclear reactors

    Science.gov (United States)

    Bennett, P. F. D.; Underhill, P. R.; Morelli, J.; Krause, T. W.

    2018-04-01

    Fuel channels in CANDU® (CANada Deuterium Uranium) nuclear reactors consist of two non-concentric tubes; an inner pressure tube (PT) and a larger diameter calandria tube (CT). Up to 400 horizontally mounted fuel channels are contained within a calandria vessel, which also holds the heavy water moderator. Certain fuel channels pass perpendicularly over horizontally oriented tubes (nozzles) that are part of the reactor's liquid injection shutdown system (LISS). Due to sag, these fuel channels are at risk of coming into contact with the LISS nozzles. In the event of contact between the LISS nozzle and CT, flow-induced vibrations from within the moderator could lead to fretting and deformation of the CT. LISS nozzle proximity to CTs is currently measured optically from within the calandria vessel, but from outside the fuel channels. Measurement by an independent means would provide confidence in optical results and supplement cases where optical observations are not possible. Separation of PT and CT, known as gap, is monitored from within the PT using a transmit-receive eddy current probe. Investigation of the eddy current based gap probe as a tool to also measure proximity of LISS nozzles was carried out experimentally in this work. Eddy current response as a function of LISS-PT proximity was recorded. When PT-CT gap, PT wall thickness, PT resistivity and probe lift-off variations were not present this dependence could be used to determine the LISS-PT proximity. This method has the potential to provide LISS-CT proximity using existing gap measurement data. Obtaining LISS nozzle proximity at multiple inspection intervals could be used to provide an estimate of the time to LISS-CT contact, and thereby provide a means of optimizing maintenance schedules.

  19. Measurement and calculation of magnetic fields associated with rail-gun currents

    International Nuclear Information System (INIS)

    Kerrisk, J.F.; Fowler, C.M.; Peterson, D.R.

    1983-01-01

    The magnetic field associated with current flow in the rails of a rail gun has been measured. The test used a magnetic flux-compression generator and a 1.2-m-long rail gun to accelerate a 4.2-g arc-driven projectile to 3.5 km/s; peak current was 900 kA. Magnetic field probes, consisting of two-turn coils 6.4 mm in diam, were located at two axial locations along the rails. Probe 3, at 0.60 m from the breech, was 28 mm from the center of the bore, and Probe 4, at 0.85 m from the breech, was 19 mm from the center of the bore. Two-dimensional calculations of the field at the probe locations were done assuming that when current starts to flow at an axial location, it is distributed on the rail surface as in the high-frequency limit. When the projectile and arc are two to three times the transverse probe separation beyond the probe, the measured field should be approximately two-dimensional. Probe signals indicate that the projectile was traveling at 3.2 km/s when it passed Probe 4. At this velocity, the projectile should be three transferse probe separations (about 60 mm) from the axial probe location in about 20 μS. Allowing for a 40-mm arc length adds about 15 μS. With these assumptions, the measured field should approach the two-dimensional limit in about 35 μS. However, about 100 μS were required. The results from Probe 3 are similar. The cause of this delay is uncertain at this time; two possibilities that are being investigated are that the arc is much longer than expected or that current flow in the rails at these axial locations is less than that measured at the breech because of spurious arcs

  20. High-precision measurement of tidal current structures using coastal acoustic tomography

    Science.gov (United States)

    Zhang, Chuanzheng; Zhu, Xiao-Hua; Zhu, Ze-Nan; Liu, Wenhu; Zhang, Zhongzhe; Fan, Xiaopeng; Zhao, Ruixiang; Dong, Menghong; Wang, Min

    2017-07-01

    A high-precision coastal acoustic tomography (CAT) experiment for reconstructing the current variation in Dalian Bay (DLB) was successfully conducted by 11 coastal acoustic tomography systems during March 7-8, 2015. The horizontal distributions of tidal currents and residual currents were mapped well by the inverse method, which used reciprocal travel time data along 51 successful sound transmission rays. The semi-diurnal tide is dominant in DLB, with a maximum speed of 0.69 m s-1 at the eastern and southwestern parts near the bay mouth that gradually decreases toward the inner bay with an average velocity of 0.31 m s-1. The residual current enters the observational domain from the two flanks of the bay mouth and flows out in the inner bay. One anticyclone and one cyclone were noted inside DLB as was one cyclone at the bay mouth. The maximum residual current in the observational domain reached 0.11 m s-1, with a mean residual current of 0.03 m s-1. The upper 15-m depth-averaged inverse velocities were in excellent agreement with the moored Acoustic Doppler Current Profiler (ADCP) at the center of the bay, with a root-mean-square difference (RMSD) of 0.04 m s-1 for the eastward and northward components. The precision of the present tomography measurements was the highest thus far owing to the largest number of transmission rays ever recorded. Sensitivity experiments showed that the RMSD between CAT and moored-ADCP increased from 0.04 m s-1 to 0.08 m s-1 for both the eastward and northward velocities when reducing the number of transmission rays from 51 to 11. The observational accuracy was determined by the spatial resolution of acoustic ray in the CAT measurements. The cost-optimal scheme consisted of 29 transmission rays with a spatial resolution of acoustic ray of 2.03 √{ km2 / ray numbers } . Moreover, a dynamic analysis of the residual currents showed that the horizontal pressure gradient of residual sea level and Coriolis force contribute 38.3% and 36

  1. Measurement and QCD Analysis of Neutral and Charged Current Cross Sections at HERA

    CERN Document Server

    Adloff, C.; Andrieu, B.; Anthonis, T.; Astvatsatourov, A.; Babaev, A.; Bahr, J.; Baranov, P.; Barrelet, E.; Bartel, W.; Baumgartner, S.; Becker, J.; Beckingham, M.; Beglarian, A.; Behnke, O.; Belousov, A.; Berger, C.; Berndt, T.; Bizot, J.C.; Bohme, J.; Boudry, V.; Braunschweig, W.; Brisson, V.; Broker, H.B.; Brown, D.P.; Bruncko, D.; Busser, F.W.; Bunyatyan, A.; Burrage, A.; Buschhorn, G.; Bystritskaya, L.; Campbell, A.J.; Cao, Jun; Caron, S.; Cassol-Brunner, F.; Chekelian, V.; Clarke, D.; Collard, C.; Contreras, J.G.; Coppens, Y.R.; Coughlan, J.A.; Cousinou, M.C.; Cox, B.E.; Cozzika, G.; Cvach, J.; Dainton, J.B.; Dau, W.D.; Daum, K.; Davidsson, M.; Delcourt, B.; Delerue, N.; Demirchyan, R.; De Roeck, A.; De Wolf, E.A.; Diaconu, C.; Dingfelder, J.; Dixon, P.; Dodonov, V.; Dowell, J.D.; Dubak, A.; Duprel, C.; Eckerlin, Guenter; Eckstein, D.; Efremenko, V.; Egli, S.; Eichler, R.; Eisele, F.; Eisenhandler, E.; Ellerbrock, M.; Elsen, E.; Erdmann, M.; Erdmann, W.; Faulkner, P.J.W.; Favart, L.; Fedotov, A.; Felst, R.; Ferencei, J.; Ferron, S.; Fleischer, M.; Fleischmann, P.; Fleming, Y.H.; Flucke, G.; Flugge, G.; Fomenko, A.; Foresti, I.; Formanek, J.; Franke, G.; Frising, G.; Gabathuler, E.; Gabathuler, K.; Garvey, J.; Gassner, J.; Gayler, Joerg; Gerhards, R.; Gerlich, C.; Ghazaryan, Samvel; Goerlich, L.; Gogitidze, N.; Grab, C.; Grabski, V.; Grassler, H.; Greenshaw, T.; Grindhammer, Guenter; Haidt, D.; Hajduk, L.; Haller, J.; Heinemann, B.; Heinzelmann, G.; Henderson, R.C.W.; Hengstmann, S.; Henschel, H.; Henshaw, O.; Heremans, R.; Herrera, G.; Herynek, I.; Hildebrandt, M.; Hilgers, M.; Hiller, K.H.; Hladky, J.; Hoting, P.; Hoffmann, D.; Horisberger, R.; Hovhannisyan, A.; Ibbotson, M.; Issever, C .; Jacquet, M.; Jaffre, M.; Janauschek, L.; Janssen, X.; Jemanov, V.; Jonsson, L.; Johnson, C.; Johnson, D.P.; Jones, M.A.S.; Jung, H.; Kant, D.; Kapichine, M.; Karlsson, M.; Karschnick, O.; Katzy, J.; Keil, F.; Keller, N.; Kennedy, J.; Kenyon, I.R.; Kiesling, Christian M.; Kjellberg, P.; Klein, M.; Kleinwort, C.; Kluge, T.; Knies, G.; Koblitz, B.; Kolya, S.D.; Korbel, V.; Kostka, P.; Koutouev, R.; Koutov, A.; Kroseberg, J.; Kruger, K.; Kuhr, T.; Lamb, D.; Landon, M.P.J.; Lange, W.; Lastovicka, T.; Laycock, P.; Lebailly, E.; Lebedev, A.; Leissner, B.; Lemrani, R.; Lendermann, V.; Levonian, S.; List, B.; Lobodzinska, E.; Lobodzinski, B.; Loginov, A.; Loktionova, N.; Lubimov, V.; Luders, S.; Luke, D.; Lytkin, L.; Malden, N.; Malinovski, E.; Mangano, S.; Marage, P.; Marks, J.; Marshall, R.; Martyn, H.U.; Martyniak, J.; Maxfield, S.J.; Meer, D.; Mehta, A.; Meier, K.; Meyer, A.B.; Meyer, H.; Meyer, J.; Michine, S.; Mikocki, S.; Milstead, D.; Mohrdieck, S.; Mondragon, M.N.; Moreau, F.; Morozov, A.; Morris, J.V.; Muller, K.; Murin, P.; Nagovizin, V.; Naroska, B.; Naumann, J.; Naumann, T.; Newman, Paul R.; Niebergall, F.; Niebuhr, C.; Nix, O.; Nowak, G.; Nozicka, M.; Olivier, B.; Olsson, J.E.; Ozerov, D.; Panassik, V.; Pascaud, C.; Patel, G.D.; Peez, M.; Perez, E.; Petrukhin, A.; Phillips, J.P.; Pitzl, D.; Portheault, B.; Poschl, R.; Potachnikova, I.; Povh, B.; Rauschenberger, J.; Reimer, P.; Reisert, B.; Risler, C.; Rizvi, E.; Robmann, P.; Roosen, R.; Rostovtsev, A.; Rusakov, S.; Rybicki, K.; Sankey, D.P.C.; Sauvan, E.; Schatzel, S.; Scheins, J.; Schilling, F.P.; Schleper, P.; Schmidt, D.; Schmidt, S.; Schmitt, S.; Schneider, M.; Schoeffel, L.; Schoning, A.; Schoerner-Sadenius, Thomas; Schroder, V.; Schultz-Coulon, H.C.; Schwanenberger, C.; Sedlak, K.; Sefkow, F.; Sheviakov, I.; Shtarkov, L.N.; Sirois, Y.; Sloan, T.; Smirnov, P.; Soloviev, Y.; South, D.; Spaskov, V.; Specka, Arnd E.; Spitzer, H.; Stamen, R.; Stella, B.; Stiewe, J.; Strauch, I.; Straumann, U.; Tchetchelnitski, S.; Thompson, Graham; Thompson, P.D.; Tomasz, F.; Traynor, D.; Truoel, Peter; Tsipolitis, G.; Tsurin, I.; Turnau, J.; Turney, J.E.; Tzamariudaki, E.; Uraev, A.; Urban, Marcel; Usik, A.; Valkar, S.; Valkarova, A.; Vallee, C.; Van Mechelen, P.; Vargas Trevino, A.; Vassiliev, S.; Vazdik, Y.; Veelken, C.; Vest, A.; Vichnevski, A.; Volchinski, V.; Wacker, K.; Wagner, J.; Wallny, R.; Waugh, B.; Weber, G.; Weber, R.; Wegener, D.; Werner, C.; Werner, N.; Wessels, M.; Wiesand, S.; Winde, M.; Winter, G.G.; Wissing, C.; Wobisch, M.; Woehrling, E.E.; Wunsch, E.; Wyatt, A.C.; Zacek, J.; Zalesak, J.; Zhang, Z.; Zhokin, A.; Zomer, F.; zur Nedden, M.

    2003-01-01

    The inclusive e^+ p single and double differential cross sections for neutral and charged current processes are measured with the H1 detector at HERA. The data were taken in 1999 and 2000 at a centre-of-mass energy of \\sqrt{s} = 319 GeV and correspond to an integrated luminosity of 65.2 pb^-1. The cross sections are measured in the range of four-momentum transfer squared Q^2 between 100 and 30000 GeV^2 and Bjorken x between 0.0013 and 0.65. The neutral current analysis for the new e^+ p data and the earlier e^- p data taken in 1998 and 1999 is extended to small energies of the scattered electron and therefore to higher values of inelasticity y, allowing a determination of the longitudinal structure function F_L at high Q^2 (110 - 700 GeV^2). A new measurement of the structure function x F_3 is obtained using the new e^+ p and previously published e^\\pm p neutral current cross section data at high Q^2. These data together with H1 low Q^2 precision data are further used to perform new next-to-leading order QCD ...

  2. Effects of synchronous irradiance monitoring and correction of current-voltage curves on the outdoor performance measurements of photovoltaic modules

    Science.gov (United States)

    Hishikawa, Yoshihiro; Doi, Takuya; Higa, Michiya; Ohshima, Hironori; Takenouchi, Takakazu; Yamagoe, Kengo

    2017-08-01

    Precise outdoor measurement of the current-voltage (I-V) curves of photovoltaic (PV) modules is desired for many applications such as low-cost onsite performance measurement, monitoring, and diagnosis. Conventional outdoor measurement technologies have a problem in that their precision is low when the solar irradiance is unstable, hence, limiting the opportunity of precise measurement only on clear sunny days. The purpose of this study is to investigate an outdoor measurement procedure, that can improve both the measurement opportunity and precision. Fast I-V curve measurements within 0.2 s and synchronous measurement of irradiance using a PV module irradiance sensor very effectively improved the precision. A small standard deviation (σ) of the module’s maximum output power (P max) in the range of 0.7-0.9% is demonstrated, based on the basis of a 6 month experiment, that mainly includes partly sunny days and cloudy days, during which the solar irradiance is unstable. The σ was further improved to 0.3-0.5% by correcting the curves for the small variation of irradiance. This indicates that the procedure of this study enables much more reproducible I-V curve measurements than a conventional usual procedure under various climatic conditions. Factors that affect measurement results are discussed, to further improve the precision.

  3. Validation of streamflow measurements made with M9 and RiverRay acoustic Doppler current profilers

    Science.gov (United States)

    Boldt, Justin A.; Oberg, Kevin A.

    2015-01-01

    The U.S. Geological Survey (USGS) Office of Surface Water (OSW) previously validated the use of Teledyne RD Instruments (TRDI) Rio Grande (in 2007), StreamPro (in 2006), and Broadband (in 1996) acoustic Doppler current profilers (ADCPs) for streamflow (discharge) measurements made by the USGS. Two new ADCPs, the SonTek M9 and the TRDI RiverRay, were first used in the USGS Water Mission Area programs in 2009. Since 2009, the OSW and USGS Water Science Centers (WSCs) have been conducting field measurements as part of their stream-gaging program using these ADCPs. The purpose of this paper is to document the results of USGS OSW analyses for validation of M9 and RiverRay ADCP streamflow measurements. The OSW required each participating WSC to make comparison measurements over the range of operating conditions in which the instruments were used until sufficient measurements were available. The performance of these ADCPs was evaluated for validation and to identify any present and potential problems. Statistical analyses of streamflow measurements indicate that measurements made with the SonTek M9 ADCP using firmware 2.00–3.00 or the TRDI RiverRay ADCP using firmware 44.12–44.15 are unbiased, and therefore, can continue to be used to make streamflow measurements in the USGS stream-gaging program. However, for the M9 ADCP, there are some important issues to be considered in making future measurements. Possible future work may include additional validation of streamflow measurements made with these instruments from other locations in the United States and measurement validation using updated firmware and software.

  4. The Perceived Invalidation of Emotion Scale (PIES): Development and psychometric properties of a novel measure of current emotion invalidation.

    Science.gov (United States)

    Zielinski, Melissa J; Veilleux, Jennifer C

    2018-05-24

    Emotion invalidation is theoretically and empirically associated with mental and physical health problems. However, existing measures of invalidation focus on past (e.g., childhood) invalidation and/or do not specifically emphasize invalidation of emotion. In this article, the authors articulate a clarified operational definition of emotion invalidation and use that definition as the foundation for development of a new measure of current perceived emotion invalidation across a series of five studies. Study 1 was a qualitative investigation of people's experiences with emotional invalidation from which we generated items. An initial item pool was vetted by expert reviewers in Study 2 and examined via exploratory factor analysis in Study 3 within both college student and online samples. The scale was reduced to 10 items via confirmatory factor analysis in Study 4, resulting in a brief but psychometrically promising measure, the Perceived Invalidation of Emotion Scale (PIES). A short-term longitudinal investigation (Study 5) revealed that PIES scores had strong test-retest reliability, and that greater perceived emotion invalidation was associated with greater emotion dysregulation, borderline features and symptoms of emotional distress. In addition, the PIES predicted changes in relational health and psychological health over a 1-month period. The current set of studies thus presents a psychometrically promising and practical measure of perceived emotion invalidation that can provide a foundation for future research in this burgeoning area. (PsycINFO Database Record (c) 2018 APA, all rights reserved).

  5. Competition in health insurance markets: limitations of current measures for policy analysis.

    Science.gov (United States)

    Scanlon, Dennis P; Chernew, Michael; Swaminathan, Shailender; Lee, Woolton

    2006-12-01

    Health care reform proposals often rely on increased competition in health insurance markets to drive improved performance in health care costs, access, and quality. We examine a range of data issues related to the measures of health insurance competition used in empirical studies published from 1994-2004. The literature relies exclusively on market structure and penetration variables to measure competition. While these measures are correlated, the degree of correlation is modest, suggesting that choice of measure could influence empirical results. Moreover, certain measurement issues such as the lack of data on PPO enrollment, the treatment of small firms, and omitted market characteristics also could affect the conclusions in empirical studies. Importantly, other types of measures related to competition (e.g., the availability of information on price and outcomes, degree of entry barriers, etc.) are important from both a theoretical and policy perspective, but their impact on market outcomes has not been widely studied.

  6. Study of rare earth separation by counter current electromigration

    International Nuclear Information System (INIS)

    Correa, Sergio Machado

    1995-08-01

    The counter current electromigration (CCEM) is an electrophoretic technique where the charged species migrate on an electrical field toward an electrolytic flux. Usually this electrolyte is a complexing agent and is necessary to increase the small differences between the species mobilities. A new column was developed, all made of acrylic, in a cylindrical shape. A set of experiments was carried out with the species Na + /K + , K + /Sm +3 , K + /Eu +3 and K + /Sm +3 /Eu +3 using the α-hydrox i-isobutyric acid o,01 M as the counter current electrolytic flux. From a synthetic mixture of 90% of samarium and 10% of europium was obtained the samarium ion in a purity better than 99,9% where the concentration of Eu was determined by the polarography technique. The potassium ion was used as a leading electrolyte. It was also measured the mobilities of the involved species in the α-HIBA medium. Two models are proposed, a stationary model and a dynamic one. A simulator of a simplified stationary model, prepared in FORTRAN language, was developed and tested toward experimental results. (author)

  7. Non-intercepting beam intensity measurements towards pico-ampere. Cryogenic current comparators for FAIR

    Energy Technology Data Exchange (ETDEWEB)

    Kurian, Febin [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Goethe University, Frankfurt am Main (Germany); Helmholtz Institute Jena (Germany); Schwickert, Marcus; Sieber, Thomas; Kowina, Piotr; Reeg, Hansjoerg [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Geithner, Rene; Neubert, Ralf; Seidel, Paul; Golm, Jessica [Friedrich-Schiller-Universitaet Jena (Germany); Stoehlker, Thomas [GSI Helmholtzzentrum fuer Schwerionenforschung (Germany); Helmholtz Institute Jena (Germany); Friedrich-Schiller-Universitaet Jena (Germany)

    2016-07-01

    To satisfy the requirement of non-interceptive measurement of beam intensity down to nA range foreseen in the upcoming FAIR accelerator facility, several Cryogenic Current Comparator (CCC) systems are planned to be installed in its beam transfer lines and storage rings. As a test bench for the development of advanced CCC systems for these installations, the existing CCC system at GSI has been recommissioned and upgraded with advanced sensor components. Successful beam intensity measurements using this upgraded CCC system will be reported in this contribution. Apart from the beam measurements, several operational aspects of the CCC system were investigated, such as the baseline drifts and various noise influences. Combining the operational experiences and boundary conditions given at various installation locations in the FAIR facility, an advanced CCC system is currently under development and is planned to be installed at the Cryring facility at GSI for test measurements. Details on the development of this advanced CCC system will also be presented in this contribution.

  8. Measurement of the Current Related Damage Rate at {-}50(°) C and Consequences on Macropixel Detector Operation in Space Experiments

    Science.gov (United States)

    Segneri, Gabriele; Brown, Craig; Carpenter, James-D.; Kuhnle, Bernd; Lauf, Thomas; Lechner, Peter; Lutz, Gerhard; Rummel, Stefan; Struder, Lothar; Treis, Johannes; Whitford, Chris

    2009-12-01

    A diode irradiation with 10-MeV protons was performed to measure the silicon current related damage rate at a temperature of -50°C. This measurement was fundamental to predict the performance of the detectors which will be used in the X-ray spectrometers of the Simbol-X and BepiColombo space missions. These detectors consist of arrays of large area silicon drift chambers with integrated depleted p-channel field effect transistors. The leakage current increase due to radiation damage and its consequent energy resolution degradation can be critical for these missions, specially for BepiColombo. These effects cannot be predicted because, during the whole missions, the sensors will be kept at temperatures below -40°C, and the existing models are based on measurements on structures which underwent annealing at higher temperatures. An irradiation experiment was performed to measure the current related damage rate at - 50°C, and the obtained value was (11.1 ± 0.2) X 10-17 A/cm. This result implies that it will be possible to achieve the Simbol-X energy resolution, whereas some annealing strategies will be needed for the BepiColombo mission. The annealing behaviour at 60°C was studied as well and the results are in agreement with the already available measurements.

  9. Experimental study of anti-tumor activity of direct current

    International Nuclear Information System (INIS)

    Ito, Hisao; Hashimoto, Shozo

    1989-01-01

    The anti-tumor activity of direct current combined with radiation was studied. The experiments were performed with fibrosarcomas (FSA, NFSA) syngenetic to C3H mice. Direct current (0.6mA, 120min) alone was effective to reduce the tumor sizes, but could not cure the tumors. When the direct current therapy (DC therapy) was combined with radiation the DC therapy following radiation was more effective than that before radiation. Using TCD 50 assay, the DC therapy enhanced the effect of a single dose of radiation with the dose-modifying factor of 1.2. However, tumor control rates by the combination therapy were more improved at the smaller doses of radiation than at the larger ones. When the single DC therapy (0.6mA, 120min) was applied immediately after the first radiation of fractionated one the combination therapy still showed the enhanced effect. However, both DC therapy and the radiation therapy were divided in three fractions, and the DC therapy (0.6mA, 40min) was applied after each radiation. Tumor growth retardation by the combination therapy was no different from that by radiation alone. This result suggests that there might be a minimum required dose of coulombs to show the effect of the combination therapy. (author)

  10. Direct Measurement of Nuclear Dependence of Charged Current Quasielasticlike Neutrino Interactions Using MINERvA

    Science.gov (United States)

    Betancourt, M.; Ghosh, A.; Walton, T.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Bodek, A.; Bravar, A.; Cai, T.; Martinez Caicedo, D. A.; Carneiro, M. F.; Dytman, S. A.; Díaz, G. A.; Felix, J.; Fields, L.; Fine, R.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Harris, D. A.; Higuera, A.; Hurtado, K.; Kiveni, M.; Kleykamp, J.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Marshall, C. M.; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman, Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schellman, H.; Sobczyk, J. T.; Solano Salinas, C. J.; Sánchez Falero, S.; Valencia, E.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; Minerva Collaboration

    2017-08-01

    Charged-current νμ interactions on carbon, iron, and lead with a final state hadronic system of one or more protons with zero mesons are used to investigate the influence of the nuclear environment on quasielasticlike interactions. The transferred four-momentum squared to the target nucleus, Q2, is reconstructed based on the kinematics of the leading proton, and differential cross sections versus Q2 and the cross-section ratios of iron, lead, and carbon to scintillator are measured for the first time in a single experiment. The measurements show a dependence on the atomic number. While the quasielasticlike scattering on carbon is compatible with predictions, the trends exhibited by scattering on iron and lead favor a prediction with intranuclear rescattering of hadrons accounted for by a conventional particle cascade treatment. These measurements help discriminate between different models of both initial state nucleons and final state interactions used in the neutrino oscillation experiments.

  11. Review of current capabilities for the measurement of stress, displacement, and in situ deformation modulus

    International Nuclear Information System (INIS)

    Schrauf, T.W.; Pratt, H.R.

    1979-12-01

    Current capabilities for the measurement of stress, displacement, and in situ deformation modulus in rock masses are reviewed as to their accuracy, sensitivity, advantages, and limitations. Consideration is given to both the instruments themselves and the measurement technique. Recommendations concerning adaptation of existing measurement techniques to repository monitoring are also discussed. These recommendations include: (1) development of a modified borehole deformation gage with improved long-term stability and reliability and reduced thermal sensitivity; (2) development of a downhole transducer type of extensometer; (3) development of a rigid inclusion type gage; (4) development of an improved vibrating wire stressmeter with greater accuracy and simplified calibration and installation requirements; and (5) modification of standard rod extensometers to improve their sensitivity

  12. Soft x-ray camera for internal shape and current density measurements on a noncircular tokamak

    International Nuclear Information System (INIS)

    Fonck, R.J.; Jaehnig, K.P.; Powell, E.T.; Reusch, M.; Roney, P.; Simon, M.P.

    1988-05-01

    Soft x-ray measurements of the internal plasma flux surface shaped in principle allow a determination of the plasma current density distribution, and provide a necessary monitor of the degree of internal elongation of tokamak plasmas with a noncircular cross section. A two-dimensional, tangentially viewing, soft x-ray pinhole camera has been fabricated to provide internal shape measurements on the PBX-M tokamak. It consists of a scintillator at the focal plane of a foil-filtered pinhole camera, which is, in turn, fiber optically coupled to an intensified framing video camera (/DELTA/t />=/ 3 msec). Automated data acquisition is performed on a stand-alone image-processing system, and data archiving and retrieval takes place on an optical disk video recorder. The entire diagnostic is controlled via a PDP-11/73 microcomputer. The derivation of the polodial emission distribution from the measured image is done by fitting to model profiles. 10 refs., 4 figs

  13. Use of an Acoustic Doppler Current Profiler (ADCP) to Measure Hypersaline Bidirectional Discharge

    Science.gov (United States)

    Johnson, K.K.; Loving, B.L.; ,

    2002-01-01

    The U.S. Geological Survey measures the exchange of flow between the north and south parts of Great Salt Lake, Utah, as part of a monitoring program. Turbidity and bidirectional flow through the breach in the causeway that divides the lake into two parts makes it difficult to measure discharge with conventional streamflow techniques. An acoustic Doppler current profiler (ADCP) can be used to more accurately define the angles of flow and the location of the interface between the layers of flow. Because of the high salinity levels measured in Great Salt Lake (60-280 parts per thousand), special methods had to be developed to adjust ADCP-computed discharges for the increased speed of sound in hypersaline waters and for water entrained at the interface between flow layers.

  14. Simultaneous measurements of ion and electron currents using a novel compact electrostatic end-loss-current detector

    Science.gov (United States)

    Hirata, M.; Miyake, Y.; Cho, T.; Kohagura, J.; Numakura, T.; Shimizu, K.; Ito, M.; Kiminami, S.; Morimoto, N.; Hirai, K.; Yamagishi, T.; Miyata, Y.; Nakashima, Y.; Miyoshi, S.; Ogura, K.; Kondoh, T.; Kariya, T.

    2006-10-01

    For the purpose of end-loss-ion and -electron analyses in open-field plasmas, a compact-sized electrostatic end-loss-current detector is proposed on the basis of a self-collection principle for suppressing the effects of secondary-electron emission from a metal collector. For employing this specific method, it is worth noting that no further additional magnetic systems except the ambient open-ended magnetic fields are required in the detector operation. This characteristic property provides a compactness of the total detection system and availability for its use in plasma confinement devices without disturbing plasma-confining magnetic fields. The detector consists of a set of parallel metal plates with respect to lines of ambient magnetic forces of a plasma device for analyzing incident ion currents along with a grid for shielding the collector against strays due to the metal-plate biasing. The characterization experiments are carried out by the use of a test-ion-beam line along with an additional use of a Helmholtz coil system for the formation of open magnetic fields similar to those in the GAMMA 10 end region. The applications of the developed end-loss-current detector in the GAMMA 10 plasma experiments are demonstrated under the conditions with simultaneous incidence of energetic electrons produced by electron-cyclotron heatings for end-loss-plugging potential formation.

  15. Model-independent study of light cone current commutators

    International Nuclear Information System (INIS)

    Gautam, S.R.; Dicus, D.A.

    1974-01-01

    An attempt is made to extract information on the nature of light cone current commutators (L. C. C.) in a model independent manner. Using simple assumptions on the validity of the DGS representation for the structure functions of deep inelastic scattering and using the Bjorken--Johnston--Low theorem it is shown that in principle the L. C. C. may be constructed knowing the experimental electron--proton scattering data. On the other hand the scaling behavior of the structure functions is utilized to study the consistency of a vanishing value for various L. C. C. under mild assumptions on the behavior of the DGS spectral moments. (U.S.)

  16. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  17. Differential current measurement in the BNL energy recovery linac test facility

    International Nuclear Information System (INIS)

    Cameron, Peter

    2006-01-01

    An energy recovery linac (ERL) test facility is presently under construction at BNL [V.N. Litvinenko, et al., High current energy recovery linac at BNL, PAC, 2005; I. Ben-Zvi, et al., Extremely high current, high brightness energy recovery linac, PAC, 2005]. The goal of this test facility is to demonstrate CW operation with an average beam current greater than 100mA, and with greater than 99.95% efficiency of current recovery. This facility will serve as a test bed for the novel high current CW photo-cathode [A. Burrill, et al., Multi-alkali photocathode development at BNL, PAC, 2005; A. Murray, et al., State-of-the-art electron guns and injector designs for energy recovery linacs, PAC, 2005], the superconducting RF cavity with HOM dampers [R. Calaga, et al., High current superconducting cavities at RHIC, EPAC, 2004; R. Calaga, et al., in: Proceedings of the 11th workshop on RF superconductivity, Lubeck, Germany, 2003], and the lattice [D. Kayran, V. Litvinenko, Novel method of emittance preservation in ERL merging system in presence of strong space charge forces, PAC, 2005; D. Kayran, et al., Optics for high brightness and high current ERL project at BNL, PAC, 2005] and feedback systems needed to insure the specified beam parameters. It is an important stepping stone for electron cooling in RHIC [I. Ben-Zvi, et al., Electron cooling of RHIC, PAC, 2005], and essential to meet the luminosity specifications of RHICII [T. Hallman, et al., RHICII/eRHIC white paper, available at http://www.bnl.gov/henp/docs/NSAC_RHICII-eRHIC_2-15-03.pdf]. The expertise and experience gained in this effort might also extend forward into a 10-20GeV ERL for the electron-ion collider eRHIC [http://www.agsrhichome.bnl.gov/eRHIC/, Appendix A, The linac-ring option, 2005]. We report here on the use of a technique of differential current measurement to monitor the efficiency of current recovery in the test facility, and investigate the possibility of using such a monitor in the machine

  18. First Measurement of one Pion Production in Charged Current Neutrino and Antineutrino events on Argon

    Energy Technology Data Exchange (ETDEWEB)

    Scanavini, Scanavini,Giacomo [Yale U.

    2017-01-01

    This thesis presents a work done in the context of the Fermilab Neutrino Intensity Frontier. In this analysis, the cross section of single charged pion production in charged-current neutrino and antineutrino interactions with the argon nucleus target are measured. These measurements are performed using the Argon Neutrino Test (ArgoNeuT) detector exposed to the Fermilab Neutrino From The Main Injector (NuMI) beam operating in the low energy antineutrino mode. The signal is a charged-current μ interaction in the detector, with exactly one charged pion exiting the target nucleus, with momentum above 100 MeV/c. There shouldn’t be any 0 or kaons in the final state. There is no restriction on other mesons or nucleons. Total and differential cross section measurements are presented. The results are reported in terms of outgoing muon angle and momentum, outgoing pion angle and angle between outgoing pion and muon. The total cross sections, averaged over the flux, are found to be 8.2 ± 0.9 (stat) +0.9 -1.1 (syst) × 10-38 cm2 per argon nuclei and 2.5 ± 0.4 (stat) ± 0.5 (syst) × 10-37 cm2 per argon nuclei for antineutrino and neutrino respectively at a mean neutrino energy of 3.6 GeV (antineutrinos) and 9.6 GeV (neutrinos). This is the first time the single pion production in charged-current interactions cross section is measured on argon nuclei.

  19. Role of turbulence fluctuations on uncertainties of acoutic Doppler current profiler discharge measurements

    Science.gov (United States)

    Tarrab, Leticia; Garcia, Carlos M.; Cantero, Mariano I.; Oberg, Kevin

    2012-01-01

    This work presents a systematic analysis quantifying the role of the presence of turbulence fluctuations on uncertainties (random errors) of acoustic Doppler current profiler (ADCP) discharge measurements from moving platforms. Data sets of three-dimensional flow velocities with high temporal and spatial resolution were generated from direct numerical simulation (DNS) of turbulent open channel flow. Dimensionless functions relating parameters quantifying the uncertainty in discharge measurements due to flow turbulence (relative variance and relative maximum random error) to sampling configuration were developed from the DNS simulations and then validated with field-scale discharge measurements. The validated functions were used to evaluate the role of the presence of flow turbulence fluctuations on uncertainties in ADCP discharge measurements. The results of this work indicate that random errors due to the flow turbulence are significant when: (a) a low number of transects is used for a discharge measurement, and (b) measurements are made in shallow rivers using high boat velocity (short time for the boat to cross a flow turbulence structure).

  20. Design and test of voltage and current probes for EAST ICRF antenna impedance measurement

    Science.gov (United States)

    Jianhua, WANG; Gen, CHEN; Yanping, ZHAO; Yuzhou, MAO; Shuai, YUAN; Xinjun, ZHANG; Hua, YANG; Chengming, QIN; Yan, CHENG; Yuqing, YANG; Guillaume, URBANCZYK; Lunan, LIU; Jian, CHENG

    2018-04-01

    On the experimental advanced superconducting tokamak (EAST), a pair of voltage and current probes (V/I probes) is installed on the ion cyclotron radio frequency transmission lines to measure the antenna input impedance, and supplement the conventional measurement technique based on voltage probe arrays. The coupling coefficients of V/I probes are sensitive to their sizes and installing locations, thus they should be determined properly to match the measurement range of data acquisition card. The V/I probes are tested in a testing platform at low power with various artificial loads. The testing results show that the deviation of coupling resistance is small for loads R L > 2.5 Ω, while the resistance deviations appear large for loads R L phase measurement error is the more significant factor leads to deleterious results rather than the amplitude measurement error. To exclude the possible ingredients that may lead to phase measurement error, the phase detector can be calibrated in steady L-mode scenario and then use the calibrated data for calculation under H-mode cases in EAST experiments.

  1. Autophagy in Drosophila: From Historical Studies to Current Knowledge

    Science.gov (United States)

    Mulakkal, Nitha C.; Nagy, Peter; Takats, Szabolcs; Tusco, Radu; Juhász, Gábor; Nezis, Ioannis P.

    2014-01-01

    The discovery of evolutionarily conserved Atg genes required for autophagy in yeast truly revolutionized this research field and made it possible to carry out functional studies on model organisms. Insects including Drosophila are classical and still popular models to study autophagy, starting from the 1960s. This review aims to summarize past achievements and our current knowledge about the role and regulation of autophagy in Drosophila, with an outlook to yeast and mammals. The basic mechanisms of autophagy in fruit fly cells appear to be quite similar to other eukaryotes, and the role that this lysosomal self-degradation process plays in Drosophila models of various diseases already made it possible to recognize certain aspects of human pathologies. Future studies in this complete animal hold great promise for the better understanding of such processes and may also help finding new research avenues for the treatment of disorders with misregulated autophagy. PMID:24949430

  2. Autophagy in Drosophila: From Historical Studies to Current Knowledge

    Directory of Open Access Journals (Sweden)

    Nitha C. Mulakkal

    2014-01-01

    Full Text Available The discovery of evolutionarily conserved Atg genes required for autophagy in yeast truly revolutionized this research field and made it possible to carry out functional studies on model organisms. Insects including Drosophila are classical and still popular models to study autophagy, starting from the 1960s. This review aims to summarize past achievements and our current knowledge about the role and regulation of autophagy in Drosophila, with an outlook to yeast and mammals. The basic mechanisms of autophagy in fruit fly cells appear to be quite similar to other eukaryotes, and the role that this lysosomal self-degradation process plays in Drosophila models of various diseases already made it possible to recognize certain aspects of human pathologies. Future studies in this complete animal hold great promise for the better understanding of such processes and may also help finding new research avenues for the treatment of disorders with misregulated autophagy.

  3. Current management of bronchiectasis: review and 3 case studies.

    Science.gov (United States)

    Silverman, Enid; Ebright, Linda; Kwiatkowski, Marianne; Cullina, Joanne

    2003-01-01

    Bronchiectasis is the abnormal, irreversible dilatation of diseased bronchi. Permanently dilated airways, usually in the medium-sized bronchi, are inflamed and often obstructed with thick, purulent secretions. Known causative factors include postinfection bronchial damage, postinhalation injury, hypersensitivity reactions, and congenital airway obstructive disorders. Typical symptoms include sputum overproduction, fever, pleurisy, dyspnea, and chronic cough. Diagnosis involves radiographic studies and pulmonary function testing. Treatment includes oral, aerosolized, or intravenous antibiotic therapy according to the severity of the exacerbation, and mucus clearance by means of bronchial hygiene assistive devices, chest physiotherapy, postural drainage, and high-frequency chest compression. We present a review of bronchiectasis and offer 3 case studies illustrating current management of different presentations, including use of aerosolized antibiotics for patients infected with Pseudomonas aeruginosa. Although an adjunctive program of pulmonary rehabilitation may be useful for patients with bronchiectasis, no confirming studies have been performed to date, and additional research in this area is warranted.

  4. Current Mathematical Methods Used in QSAR/QSPR Studies

    Directory of Open Access Journals (Sweden)

    Peixun Liu

    2009-04-01

    Full Text Available This paper gives an overview of the mathematical methods currently used in quantitative structure-activity/property relationship (QASR/QSPR studies. Recently, the mathematical methods applied to the regression of QASR/QSPR models are developing very fast, and new methods, such as Gene Expression Programming (GEP, Project Pursuit Regression (PPR and Local Lazy Regression (LLR have appeared on the QASR/QSPR stage. At the same time, the earlier methods, including Multiple Linear Regression (MLR, Partial Least Squares (PLS, Neural Networks (NN, Support Vector Machine (SVM and so on, are being upgraded to improve their performance in QASR/QSPR studies. These new and upgraded methods and algorithms are described in detail, and their advantages and disadvantages are evaluated and discussed, to show their application potential in QASR/QSPR studies in the future.

  5. Measurement of multiplicity and momentum spectra in the current fragmentation region of the Breit frame at HERA

    International Nuclear Information System (INIS)

    Derrick, M.; Krakauer, D.; Magill, S.

    1995-01-01

    Charged particle production has been measured in Deep Inelastic Scattering (DIS) events using the ZEUS detector over a large range of Q 2 from 10 to 1280 GeV 2 . The evolution with Q of the charged multiplicity and scaled momentum has been investigated in the current fragmentation region of the Breit frame. The data are used to study QCD coherence effects in DIS and are compared with corresponding e + e - data in order to test the universality of quark fragmentation. (orig.)

  6. Current Profile and Magnetic Structure Measurements through Tangential Soft X-Ray Imaging in Compact Tori

    International Nuclear Information System (INIS)

    Fonck, Raymond J.

    2004-01-01

    This report describes the fabrication and tests of a tangentially imaging soft X-ray (SXR) camera diagnostic for fusion energy plasma research. It can be used for the determination of the current distribution in strongly shaped toroidal magnetically confined plasmas, such as those found in spherical tori or advanced tokamaks. It included the development of both an appropriate imaging SXR camera and image analysis techniques necessary to deduce the plasma shape and current distribution. The basic camera concept consists of a tangentially viewing pinhole imaging system with thin-film SXR filters, a scintillator screen to provide SXR to visible conversion, a fast shuttering system, and an sensitive visible camera imaging device. The analysis approach consists of integrating the 2-D SXR image data into a Grad-Shafranov toroidal equilibrium solver code to provide strong constraints on the deduced plasma current and pressure profiles. Acceptable sensitivity in the deduced current profile can be obtained if the relative noise in the measured image can be kept in the range of 1% or less. Tests on the Pegasus Toroidal Experiment indicate very flat safety factor profiles in the plasma interior

  7. Comparison of Measured Dark Current Distributions with Calculated Damage Energy Distributions in HgCdTe

    Science.gov (United States)

    Marshall, C. J.; Marshall, P. W.; Howe, C. L.; Reed, R. A.; Weller, R. A.; Mendenhall, M.; Waczynski, A.; Ladbury, R.; Jordan, T. M.

    2007-01-01

    This paper presents a combined Monte Carlo and analytic approach to the calculation of the pixel-to-pixel distribution of proton-induced damage in a HgCdTe sensor array and compares the results to measured dark current distributions after damage by 63 MeV protons. The moments of the Coulombic, nuclear elastic and nuclear inelastic damage distributions were extracted from Monte Carlo simulations and combined to form a damage distribution using the analytic techniques first described in [1]. The calculations show that the high energy recoils from the nuclear inelastic reactions (calculated using the Monte Carlo code MCNPX [2]) produce a pronounced skewing of the damage energy distribution. While the nuclear elastic component (also calculated using the MCNPX) contributes only a small fraction of the total nonionizing damage energy, its inclusion in the shape of the damage across the array is significant. The Coulombic contribution was calculated using MRED [3-5], a Geant4 [4,6] application. The comparison with the dark current distribution strongly suggests that mechanisms which are not linearly correlated with nonionizing damage produced according to collision kinematics are responsible for the observed dark current increases. This has important implications for the process of predicting the on-orbit dark current response of the HgCdTe sensor array.

  8. Current tritium chemical studies at Oak Ridge National Laboratory

    International Nuclear Information System (INIS)

    Smith, F.J.; Redman, J.D.; Strehlow, R.A.; Bell, J.T.

    1975-01-01

    The equilibrium pressures of hydrogen isotopes in the Li-LiH-H 2 , Li-LiD-D 2 and Li-LiT-T 2 systems are being measured. The solubility of hydrogen in lithium was studied and the data are in reasonable agreement with the literature values. The Li-LiD-D 2 system is now being studied. The first experimental measurements of the equilibrium pressures of tritium between 700 and 1000 0 C as a function of the LiT concentration in the Li-LiT-T 2 system have also been completed. The permeation of tritium through clean metals and through metals under simulated steam generator conditions is being investigated. Measurements of tritium permeation through clean nickel at temperatures between 636 and 910 0 K were made using a mixed isotope technique. The tritium permeability, DK/sub s/', as a function of temperature was determined to be ln DK/sub s/' [cc(NTP).mm.min -1 .torr/sup -1/2/.cm -2 ] = -0.906 - 6360/T( 0 K). The measured permeation activation energy was 12.6 +- 0.4 kcal/mole. (MOW)

  9. Measurement of K+ production in charged-current νμ interactions

    Science.gov (United States)

    Marshall, C. M.; Aliaga, L.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Budd, H.; Cai, T.; Carneiro, M. F.; Chvojka, J.; da Motta, H.; Devan, J.; Dytman, S. A.; Díaz, G. A.; Eberly, B.; Endress, E.; Felix, J.; Fields, L.; Filkins, A.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Griswold, S.; Harris, D. A.; Higuera, A.; Hurtado, K.; Kiveni, M.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Majoros, I.; Manly, S.; Mann, W. A.; Martinez Caicedo, D. A.; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman, Osta, J.; Paolone, V.; Park, J.; Patrick, C. E.; Perdue, G. N.; Rakotondravohitra, L.; Ramirez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Rosenberg, M.; Ruterbories, D.; Schellman, H.; Schmitz, D. W.; Shadler, L. A.; Simon, C.; Solano Salinas, C. J.; Sánchez, S. F.; Tice, B. G.; Valencia, E.; Walton, T.; Wang, Z.; Watkins, P.; Wiley, K.; Wolcott, J.; Wospakrik, M.; Zhang, D.; Minerva Collaboration

    2016-07-01

    Production of K+ mesons in charged-current νμ interactions on plastic scintillator (CH) is measured using MINERvA exposed to the low-energy NuMI beam at Fermilab. Timing information is used to isolate a sample of 885 charged-current events containing a stopping K+ which decays at rest. The differential cross section in K+ kinetic energy, d σ /d TK, is observed to be relatively flat between 0 and 500 MeV. Its shape is in good agreement with the prediction by the genie neutrino event generator when final-state interactions are included, however the data rate is lower than the prediction by 15%.

  10. Measurement of the $Z/A$ dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topaksu, A; Van Dantzig, R; De Jong, M; Konijn, J; Melzer, O; Oldeman, R G C; Pesen, E; Van der Poel, C A F J; Spada, F R; Visschers, J L; Güler, M; Serin-Zeyrek, M; Kama, S; Sever, R; Tolun, P; Zeyrek, M T; Armenise, N; Catanesi, M G; De Serio, M; Ieva, M; Muciaccia, M T; Radicioni, E; Simone, S; Bülte, A; Winter, Klaus; El-Aidi, R; Van de Vyver, B; Vilian, P; Wilquet, G; Saitta, B; Di Capua, E; Ogawa, S; Shibuya, H; Artamonov, A V; Brunner, J; Chizhov, M; Cussans, D G; Doucet, M; Fabre, Jean-Paul; Hristova, I R; Kawamura, T; Kolev, D; Litmaath, M; Meinhard, H; Panman, J; Papadopoulos, I M; Ricciardi, S; Rozanov, A; Saltzberg, D; Tsenov, R V; Uiterwijk, J W E; Zucchelli, P; Goldberg, J; Chikawa, M; Arik, E; Song, J S; Yoon, C S; Kodama, K; Ushida, N; Aoki, S; Hara, T; Delbar, T; Favart, D; Grégoire, G; Kalinin, S; Makhlyoueva, I V; Gorbunov, P; Khovanskii, V D; Shamanov, V V; Tsukerman, I; Bruski, N; Frekers, D; Rondeshagen, D; Wolff, T; Hoshino, K; Kawada, J; Komatsu, M; Miyanishi, M; Nakamura, M; Nakano, T; Narita, K; Niu, K; Niwa, K; Nonaka, N; Sato, O; Toshito, T; Buontempo, S; Cocco, A G; D'Ambrosio, N; De Lellis, G; De Rosa, G; Di Capua, F; Ereditato, A; Fiorillo, G; Marotta, A; Messina, M; Migliozzi, P; Pistillo, C; Santorelli, R; Scotto-Lavina, L; Strolin, P; Tioukov, V; Nakamura, K; Okusawa, T; Dore, U; Loverre, P F; Ludovici, L; Maslennikov, A L; Righini, P; Rosa, G; Santacesaria, R; Satta, A; Barbuto, E; Bozza, C; Grella, G; Romano, G; Sirignano, C; Sorrentino, S; Sato, Y; Tezuka, I

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu_mu + N -> mu^- + X. The targets, passive blocks of ~100kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematics effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio.

  11. Measurement of the Z/A dependence of neutrino charged-current total cross-sections

    CERN Document Server

    Kayis-Topasku, A; Dantzig, R V

    2003-01-01

    A relative measurement of total cross-sections is reported for polyethylene, marble, iron, and lead targets for the inclusive charged-current reaction nu submu + N -> mu sup - + X. The targets, passive blocks of propor to 100 kg each, were exposed simultaneously to the CERN SPS wide-band muon-neutrino beam over a period of 18 weeks. Systematic effects due to differences in the neutrino flux and detector efficiency for the different target locations were minimised by changing the position of the four targets on their support about every two weeks. The relative neutrino fluxes on the targets were monitored within the same experiment using charged-current interactions in the calorimeter positioned directly downstream of the four targets. From a fit to the Z/A dependence of the total cross-sections a value is deduced for the effective neutron-to-proton cross-section ratio. (orig.)

  12. Current status of programmes to measure and reduce radon exposure in Irish workplaces

    International Nuclear Information System (INIS)

    Colgan, P A; Madden, J S; Synnott, H; Fennell, S; Pollard, D; Fenton, D

    2004-01-01

    National legislation, which implements European Council Directive 96/29/EURATOM in Ireland, sets a reference level of 400 Bq m -3 averaged over any 3 month period for radon exposure in the workplace and also empowers the Radiological Protection Institute of Ireland to direct employers to have radon measurements carried out. This legislation came into effect in May 2000. Radon measurements have already been completed in show caves and other underground workplaces. Between 1998 and 2001, over 33 800 individual radon measurements were carried out in all ground floor offices and classrooms in 3444 schools nationwide as part of a programme undertaken jointly with the Department of Education and Science. Where the average indoor radon concentration in one or more rooms exceeded 200 Bq m -3 , remedial measures were implemented. For concentrations up to 400 Bq m -3 this involved increased ventilation while for higher concentrations an active sump was normally installed. The results of the survey, as well as the effectiveness of the different remedial strategies, are discussed. In the case of other above ground workplaces, different approaches have been adopted. As a first step, workplaces in two known high radon areas were directed to have radon measurements carried out. This programme had limited success because of problems in obtaining accurate workplace databases and a general lack of awareness on the part of employers of the issues involved. From a sample of 2610 employers directed to measure radon, only 408 actually completed measurements and 37 workplaces were identified as having average 3 month average radon concentrations above 400 Bq m -3 . A total of 1356 employers ignored all correspondence, some of which was sent by registered post and signed for on receipt. Current initiatives are focused on the provision of information and include newspaper advertising as well as publications aimed specifically at both employer and employee representative groups. The ability

  13. A Measurement of the Charged-Current Interaction Cross Section of the Tau Neutrino

    Energy Technology Data Exchange (ETDEWEB)

    Maher, Emily O' Connor [Univ. of Minnesota, Minneapolis, MN (United States)

    2007-02-01

    The Fermilab experiment E872 (DONUT) was designed to make the first observation of the tau neutrino charged-current interaction. Using a hybrid emulsion-spectrometer detector, the tau lepton was identified by its single-prong or trident decay. Six interactions were observed, of which five were in the deep inelastic scattering region. These five interaction were used to measure the charged-current cross section of the tau neutrino. To minimize uncertainties, the tau neutrino cross section was measured relative to the electron neutrino cross section. The result σντNconstνeNconst = 0.77 ± 0.39 is consistent with 1.0, which is predicted by lepton universality. The tau neutrino cross section was also measured for 115 GeV neutrinos, which was the average energy of the interacted tau neutrinos. The result σντNexp = 45 ± 21 x 10-38 cm2 is consistent with the standard model prediction calculated in this thesis, σντNSM = 48 ± 5 x 10-38 cm2.

  14. Policy responses to problematic video game use: A systematic review of current measures and future possibilities.

    Science.gov (United States)

    Király, Orsolya; Griffiths, Mark D; King, Daniel L; Lee, Hae-Kook; Lee, Seung-Yup; Bányai, Fanni; Zsila, Ágnes; Takacs, Zsofia K; Demetrovics, Zsolt

    2017-09-01

    Background and aims Empirical research into problematic video game playing suggests that overuse might cause functional and psychological impairments for a minority of gamers. Therefore, the need for regulation in the case of video games (whether governmental or self-imposed) has arisen but has only been implemented in a few countries around the world, and predominantly in Asia. This paper provides a systematic review of current and potential policies addressing problematic gaming. Methods After conducting a systematic search in the areas of prevention, treatment, and policy measures relating to problematic Internet and video game use, papers were selected that targeted problematic gaming policies (N = 12; six in English and six in Korean). These papers served as the basis of this review. Results Policies were classified into three major groups: (i) policy measures limiting availability of video games (e.g., shutdown policy, fatigue system, and parental controls), (ii) measures aiming to reduce risk and harm (e.g., warning messages), and (iii) measures taken to provide help services for gamers. Beyond the attempt to classify the current and potential policy measures, the authors also tried to evaluate their efficiency theoretically and (if data were available) empirically. Discussion and conclusions Overall, it appears that although several steps have been taken to address problematic video game playing, most of these steps were not as effective as expected, or had not been evaluated empirically for efficacy. The reason for this may lie in the fact that the policies outlined only addressed or influenced specific aspects of the problem instead of using a more integrative approach.

  15. Precision neutral current asymmetry parameter measurements from the Tau polarization at LEP

    International Nuclear Information System (INIS)

    Abbiendi, G.; Aakesson, P.F.

    2001-01-01

    Measurements of the τ lepton polarization and forward-backward polarization asymmetry near the Z 0 resonance using the OPAL detector are described. The measurements are based on analyses of τ→ν e ν τ , τ→μν μ ν τ , τ→πν τ , τ→ρν τ and τ→ 1 ν τ decays from a sample of 144,810 e + e - →τ + τ - candidates corresponding to an integrated luminosity of 151 pb -1 . Assuming that the τ lepton decays according to V-A theory, we measure the average τ polarization near √(s) =M Z to be left angle P τ right angle = (-14.10 ±0.73 ±0.55)% and the τ polarization forward-backward asymmetry to be A pol FB = (-10.55 ±0.76 ±0.25)%, where the first error is statistical and the second systematic. Taking into account the small effects of the photon propagator, photon-Z 0 interference and photonic radiative corrections, these results can be expressed in terms of the lepton neutral current asymmetry parameters: A τ =0.1456±0.0076±0.0057, A e =0.1454±0.0108±0.0036. These measurements are consistent with the hypothesis of lepton universality and combine to give A l = 0.1455 ±0.0073. Within the context of the Standard Model this combined result corresponds to =0.23172 ±0.00092. Combing these results with those from the other OPAL neutral current measurements yields a value of =0.23211 ±0.00068. (orig.)

  16. Evaluation and comparison of current fetal ultrasound image segmentation methods for biometric measurements: a grand challenge.

    Science.gov (United States)

    Rueda, Sylvia; Fathima, Sana; Knight, Caroline L; Yaqub, Mohammad; Papageorghiou, Aris T; Rahmatullah, Bahbibi; Foi, Alessandro; Maggioni, Matteo; Pepe, Antonietta; Tohka, Jussi; Stebbing, Richard V; McManigle, John E; Ciurte, Anca; Bresson, Xavier; Cuadra, Meritxell Bach; Sun, Changming; Ponomarev, Gennady V; Gelfand, Mikhail S; Kazanov, Marat D; Wang, Ching-Wei; Chen, Hsiang-Chou; Peng, Chun-Wei; Hung, Chu-Mei; Noble, J Alison

    2014-04-01

    This paper presents the evaluation results of the methods submitted to Challenge US: Biometric Measurements from Fetal Ultrasound Images, a segmentation challenge held at the IEEE International Symposium on Biomedical Imaging 2012. The challenge was set to compare and evaluate current fetal ultrasound image segmentation methods. It consisted of automatically segmenting fetal anatomical structures to measure standard obstetric biometric parameters, from 2D fetal ultrasound images taken on fetuses at different gestational ages (21 weeks, 28 weeks, and 33 weeks) and with varying image quality to reflect data encountered in real clinical environments. Four independent sub-challenges were proposed, according to the objects of interest measured in clinical practice: abdomen, head, femur, and whole fetus. Five teams participated in the head sub-challenge and two teams in the femur sub-challenge, including one team who tackled both. Nobody attempted the abdomen and whole fetus sub-challenges. The challenge goals were two-fold and the participants were asked to submit the segmentation results as well as the measurements derived from the segmented objects. Extensive quantitative (region-based, distance-based, and Bland-Altman measurements) and qualitative evaluation was performed to compare the results from a representative selection of current methods submitted to the challenge. Several experts (three for the head sub-challenge and two for the femur sub-challenge), with different degrees of expertise, manually delineated the objects of interest to define the ground truth used within the evaluation framework. For the head sub-challenge, several groups produced results that could be potentially used in clinical settings, with comparable performance to manual delineations. The femur sub-challenge had inferior performance to the head sub-challenge due to the fact that it is a harder segmentation problem and that the techniques presented relied more on the femur's appearance.

  17. Simultaneous measurement of current and temperature distributions in a proton exchange membrane fuel cell during cold start processes

    International Nuclear Information System (INIS)

    Jiao Kui; Alaefour, Ibrahim E.; Karimi, Gholamreza; Li Xianguo

    2011-01-01

    Cold start is critical to the commercialization of proton exchange membrane fuel cell (PEMFC) in automotive applications. Dynamic distributions of current and temperature in PEMFC during various cold start processes determine the cold start characteristics, and are required for the optimization of design and operational strategy. This study focuses on an investigation of the cold start characteristics of a PEMFC through the simultaneous measurements of current and temperature distributions. An analytical model for quick estimate of purging duration is also developed. During the failed cold start process, the highest current density is initially near the inlet region of the flow channels, then it moves downstream, reaching the outlet region eventually. Almost half of the cell current is produced in the inlet region before the cell current peaks, and the region around the middle of the cell has the best survivability. These two regions are therefore more important than other regions for successful cold start through design and operational strategy, such as reducing the ice formation and enhancing the heat generation in these two regions. The evolution of the overall current density distribution over time remains similar during the successful cold start process; the current density is the highest near the flow channel inlets and generally decreases along the flow direction. For both the failed and the successful cold start processes, the highest temperature is initially in the flow channel inlet region, and is then around the middle of the cell after the overall peak current density is reached. The ice melting and liquid formation during the successful cold start process have negligible influence on the general current and temperature distributions.

  18. Measuring situation awareness in complex systems: Comparison of measures study

    OpenAIRE

    Salmon, PM; Stanton, NA; Walker, GH; Jenkins, DP; Ladva, D; Rafferty, L; Young, MS

    2008-01-01

    Situation Awareness (SA) is a distinct critical commodity for teams working in complex industrial systems and its measurement is a key provision in system, procedural and training design efforts. This article describes a study that was undertaken in order to compare three different SA measures (a freeze probe recall approach, a post trial subjective rating approach and a critical incident interview technique) when used to assess participant SA during a military planning task. The results indi...

  19. An induced current method for measuring zeta potential of electrolyte solution-air interface.

    Science.gov (United States)

    Song, Yongxin; Zhao, Kai; Wang, Junsheng; Wu, Xudong; Pan, Xinxiang; Sun, Yeqing; Li, Dongqing

    2014-02-15

    This paper reports a novel and very simple method for measuring the zeta potential of electrolyte solution-air interface. When a measuring electrode contacts the electrolyte solution-air interface, an electrical current will be generated due to the potential difference between the electrode-air surface and the electrolyte solution-air interface. The amplitude of the measured electric signal is linearly proportional to this potential difference; and depends only on the zeta potential at the electrolyte solution-air interface, regardless of the types and concentrations of the electrolyte. A correlation between the zeta potential and the measured voltage signal is obtained based on the experimental data. Using this equation, the zeta potential of any electrolyte solution-air interface can be evaluated quickly and easily by inserting an electrode through the electrolyte solution-air interface and measuring the electrical signal amplitude. This method was verified by comparing the obtained results of NaCl, MgCl2 and CaCl2 solutions of different pH values and concentrations with the zeta potential data reported in the published journal papers. Copyright © 2013 Elsevier Inc. All rights reserved.

  20. Farfield Ion Current Density Measurements before and after the NASA HiVHAc EDU2 Vibration Test

    Science.gov (United States)

    Huang, Wensheng; Kamhawi, Hani; Shastry, Rohit

    2012-01-01

    There is an increasing need to characterize the plasma plume of the NASA HiVHAc thruster in order to better understand the plasma physics and to obtain data for spacecraft interaction studies. To address this need, the HiVHAc research team is in the process of developing a number of plume diagnostic systems. This paper presents the initial results of the farfield current density probe diagnostic system. Farfield current density measurements were carried out before and after a vibration test of the HiVHAc engineering development unit 2 that simulate typical launch conditions. The main purposes of the current density measurements were to evaluate the thruster plume divergence and to investigate any changes in the plasma plume that may occur as a result of the vibration test. Radial sweeps, as opposed to the traditional polar sweeps, were performed during these tests. The charged-weighted divergence angles were found to vary from 16 to 28 degrees. Charge density profiles measured pre- and post-vibration-test were found to be in excellent agreement. This result, alongside thrust measurements reported in a companion paper, confirm that the operation of the HiVHAc engineering development unit 2 were not altered by full-level/random vibration testing.

  1. Determination of the energy gap in photoconducting insulators through current noise measurements

    International Nuclear Information System (INIS)

    Carbone, A.; Demichelis, F.; Mazzetti, P.

    1989-01-01

    Measurements of the current noise power spectrum of the photoconducting insulators CdS and CdSe irradiated with monochromatic light of different wavelength λ are reported. It is shown that there is an abrupt change of about one order of magnitude in the low frequency power density of the noise when λ crosses the photoconductor gap value λ and the photocurrent and the device conductance are kept constant by varying the light intensity. The effect is explained in terms of an abrupt increase of the carrier recombination rate when the photon energy becomes larger than the energy gap of the photoconductor. Possible applications of these results are briefly discussed

  2. Determination of deep levels in semi-insulating cadmium telluride by thermally stimulated current measurements

    International Nuclear Information System (INIS)

    Scharager, C.; Muller, J.C.; Stuck, R.; Siffert, P.

    1975-01-01

    Thermally stimulated current (TSC) measurements have been performed in high resistivity (rho approximately 10 7 ohms.cm) CdTe γ-ray detectors between 35 and 300K. The TSC curves have been analyzed by different methods, including those taking into account the retrapping of the carriers. The trap characteristics have been determined; especially three levels located at E(v)+0.13eV, E(v)+0.30eV and E(c)-0.55eV have been investigated [fr

  3. Ocean current surface measurement using dynamic elevations obtained by the GEOS-3 radar altimeter

    Science.gov (United States)

    Leitao, C. D.; Huang, N. E.; Parra, C. G.

    1977-01-01

    Remote Sensing of the ocean surface from the GEOS-3 satellite using radar altimeter data has confirmed that the altimeter can detect the dynamic ocean topographic elevations relative to an equipotential surface, thus resulting in a reliable direct measurement of the ocean surface. Maps of the ocean dynamic topography calculated over a one month period and with 20 cm contour interval are prepared for the last half of 1975. The Gulf Stream is observed by the rapid slope change shown by the crowding of contours. Cold eddies associated with the current are seen as roughly circular depressions.

  4. Pulse measurement of the hot spot current in a NbTiN superconducting filament

    Science.gov (United States)

    Harrabi, K.; Mekki, A.; Kunwar, S.; Maneval, J. P.

    2018-02-01

    We have studied the voltage response of superconducting NbTiN filaments to a step-pulse of over-critical current I > Ic. The current induces the destruction of the Cooper pairs and initiates different mechanisms of dissipation depending on the bath temperature T. For the sample investigated, and for T above a certain T*, not far from Tc, the resistance manifests itself in the form of a phase-slip center, which turns into a normal hot spot (HS) as the step-pulse is given larger amplitudes. However, at all temperatures below T*, the destruction of superconductivity still occurs at Ic(T), but leads directly to an ever-growing HS. By lowering the current amplitude during the pulse, one can produce a steady HS and thus define a threshold HS current Ih(T). That is achieved by combining two levels of current, the first and larger one to initiate an HS, the second one to search for constant voltage response. The double diagram of the functions Ic(T) and Ih(T) was plotted in the T-range Tc/2 < T < Tc, and their crossing found at T* = (8.07 ± 0.07) K.

  5. Measurements of the neutral current e{sup {+-}}p cross sections using longitudinally polarised lepton beams at HERA II

    Energy Technology Data Exchange (ETDEWEB)

    Nikiforov, A.

    2007-01-18

    This thesis presents inclusive e{sup {+-}}p single and double differential cross sections for neutral current deep inelastic scattering measured as functions of the four-momentum transfer squared Q{sup 2} and the Bjorken variable x in interactions of longitudinally polarised leptons with unpolarised protons using the H1 detector at HERA II. An overview of the phenomenology of deep inelastic scattering is given and the experimental apparatus as well as the measurement and analysis procedures are described. The analysis is based on e{sup +}p data taken in 2003-04 and e{sup -}p data taken in 2005 at a centre-of-mass energy of {radical}(s)=318 GeV, with integrated luminosities of 47.6 pb{sup -1} and 98.4 pb{sup -1} for the e{sup +}p and e{sup -}p samples, respectively. The cross sections are measured in the range of 200measurements are used to study polarisation e ects in neutral current interactions and to determine the structure function xF{sub 3}. The new HERA II data are combined together with previously published data from HERA I to determine the structure function xF{sub 3} with improved precision. Furthermore, this measurement is combined with the corresponding ZEUS measurement to provide the most accurate measurement of the interference structure function xF{sup {gamma}}{sup Z}{sub 3}, which is sensitive to the valence quark distributions down to low values of x. The data on polarised cross section asymmetries A{sup {+-}} are also combined with the ZEUS data. This leads to the first observation of parity violation in neutral current e{sup {+-}}p scattering at distances down to 10{sup -18} m. The data are well described by the Standard Model predictions. (orig.)

  6. Current 2-μm dial measurements of atmospheric CO2 and expected results from space using new MCT APDS

    Science.gov (United States)

    Dumas, A.; Gibert, F.; Rothman, J.; Édouart, D.; Le Mounier, F.; Cénac, C.

    2017-11-01

    In the framework of CO2 monitoring in the Atmospheric Boundary Layer (ABL), a ground-based 2-μm Differential Absorption Lidar (DIAL) has been developed at the Laboratoire de Météorologie Dynamique (LMD) in Palaiseau. In order to derive flux information, this system has been set up with coherent detection, which allows to combine CO2 density measurements with wind velocity measurements. On the other hand, new advances in the field of Mercury Cadmium Tellure (MCT) Avalanche Photodiodes (APDs) open the way for high-precision measurements in direct detection ultimately from space. In this study, we first report on state of the art measurements obtained with the current coherent DIAL system before presenting expected results for a similar laser transmitter equipped with MCT APDs. For this latter part, we use a numerical model which relies on APDs performance data provided by the Laboratoire d'Électronique et de Technologie de l'Information (LETI).

  7. Current distribution evaluation of dye-sensitized solar cell using HTS-SQUID-based magnetic measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Sakai, Kenji, E-mail: Sakai-k@okayama-u.ac.jp; Tanaka, Kohei; Kiwa, Toshihiko; Tsukada, Keiji

    2016-11-15

    Highlights: • Current distribution and direction of dye-sensitized solar cell (DSSC) was measured. • Electrical current flowing in the indium tin oxide (ITO) glass substrate was uniform. • The distribution of electrical current depended on I–V characteristic. • Current direction changed when the performance of DSSC is low. - Abstract: The current flowing inside a dye-sensitized solar cell (DSSC) was measured using a high-temperature superconductor superconducting quantum interference device (HTS-SQUID)-based magnetic measurement system. Further, a new evaluation method of the DSSC, which is difficult to measure using the conventional method, was investigated to improve the characteristics of the DSSC. The tangential components of the magnetic field generated from the DSSC were measured using two HTS-SQUIDs, and the intensity and direction related to the electrical current were obtained by the measured magnetic field. The DSSCs prepared with different dyes and catalytic substances showed different current-intensity mapping. The current direction was different for the DSSC with low performance. In addition, the current flowing in the ITO layer of the ITO glass substrate was also measured and the results confirmed that it had uniform distribution. These results show that the current mapping and the direction of the electrical current depend on the internal factors of the DSSC, and the detection of the magnetic field distribution generated from it is expected to lead to its new evaluation method.

  8. Novel Faraday cup for the simultaneous observation and measurement of ion-beam currents

    International Nuclear Information System (INIS)

    Wei, C.Y.; Seidman, D.N.

    1977-07-01

    The Faraday cup is constructed around a Galileo channel electron multiplier array (CEMA) which serves as the basis of an internal image intensification system (a gain of greater than 10 4 ) for the observation of the ion beam; the CEMA also acts as a collector for the ion cured by a Keithley 602 electrometer. The ion current is integrated by a simple and inexpensive dosimeter; the electronic circuit for the dosimeter is described. The application of the Faraday cup to the observation and measurement of a 30 keV Ar + ion beam is presented as an illustrative example. This Faraday cup was also employed to observe and measure 30 keV Cr + , Mo + or W + and 18 keV Au + ion beams employed for the in-situ irradiation of field-ion microscope specimens

  9. Four-point probe measurements of a direct current potential drop on layered conductive cylinders

    International Nuclear Information System (INIS)

    Lu, Yi; Bowler, John R

    2012-01-01

    We have determined the steady state electric field due to direct current flowing via point contacts at the cylindrical surface of a uniformly layered conductive rod of finite length. The solution allows one to use four-point probe potential drop measurements to estimate the conductivity or thickness of the layer assuming that the other parameters are known. The electrical potential in the rod has a zero radial derivative at its surface except at the injection and extractions points. This means that the required solution can be expressed in terms of a Green’s function satisfying a Neumann boundary condition. Four-point measurements have been made to demonstrate the validity of theoretical results. (paper)

  10. Four-point probe measurements of a direct current potential drop on layered conductive cylinders

    Science.gov (United States)

    Lu, Yi; Bowler, John R.

    2012-11-01

    We have determined the steady state electric field due to direct current flowing via point contacts at the cylindrical surface of a uniformly layered conductive rod of finite length. The solution allows one to use four-point probe potential drop measurements to estimate the conductivity or thickness of the layer assuming that the other parameters are known. The electrical potential in the rod has a zero radial derivative at its surface except at the injection and extractions points. This means that the required solution can be expressed in terms of a Green’s function satisfying a Neumann boundary condition. Four-point measurements have been made to demonstrate the validity of theoretical results.

  11. Measurement of the spectral functions of vector current hadronic $\\tau$ decays

    CERN Document Server

    Barate, R; Décamp, D; Ghez, P; Goy, C; Lees, J P; Lucotte, A; Minard, M N; Nief, J Y; Pietrzyk, B; Casado, M P; Chmeissani, M; Comas, P; Crespo, J M; Delfino, M C; Fernández, E; Fernández-Bosman, M; Garrido, L; Juste, A; Martínez, M; Miquel, R; Mir, L M; Orteu, S; Padilla, C; Park, I C; Pascual, A; Perlas, J A; Riu, I; Sánchez, F; Teubert, F; Colaleo, A; Creanza, D; De Palma, M; Gelao, G; Iaselli, Giuseppe; Maggi, G; Maggi, M; Marinelli, N; Nuzzo, S; Ranieri, A; Raso, G; Ruggieri, F; Selvaggi, G; Silvestris, L; Tempesta, P; Tricomi, A; Zito, G; Huang, X; Lin, J; Ouyang, Q; Wang, T; Xie, Y; Xu, R; Xue, S; Zhang, J; Zhang, L; Zhao, W; Abbaneo, D; Alemany, R; Becker, U; Bazarko, A O; Bright-Thomas, P G; Cattaneo, M; Cerutti, F; Drevermann, H; Forty, Roger W; Frank, M; Hagelberg, R; Harvey, J; Janot, P; Jost, B; Kneringer, E; Knobloch, J; Lehraus, Ivan; Lutters, G; Mato, P; Minten, Adolf G; Moneta, L; Pacheco, A; Pusztaszeri, J F; Ranjard, F; Rensing, P E; Rizzo, G; Rolandi, Luigi; Schlatter, W D; Schmitt, M; Schneider, O; Tejessy, W; Tomalin, I R; Wachsmuth, H W; Wagner, A; Ajaltouni, Ziad J; Barrès, A; Boyer, C; Falvard, A; Ferdi, C; Gay, P; Guicheney, C; Henrard, P; Jousset, J; Michel, B; Monteil, S; Montret, J C; Pallin, D; Perret, P; Podlyski, F; Proriol, J; Rosnet, P; Rossignol, J M; Fearnley, Tom; Hansen, J B; Hansen, J D; Hansen, J R; Hansen, P H; Nilsson, B S; Rensch, B; Wäänänen, A; Daskalakis, G; Kyriakis, A; Markou, C; Simopoulou, Errietta; Siotis, I; Vayaki, Anna; Blondel, A; Bonneaud, G R; Brient, J C; Bourdon, P; Rougé, A; Rumpf, M; Valassi, Andrea; Verderi, M; Videau, H L; Candlin, D J; Parsons, M I; Focardi, E; Parrini, G; Zachariadou, K; Corden, M; Georgiopoulos, C H; Jaffe, D E; Antonelli, A; Bencivenni, G; Bologna, G; Bossi, F; Campana, P; Capon, G; Casper, David William; Chiarella, V; Felici, G; Laurelli, P; Mannocchi, G; Murtas, F; Murtas, G P; Passalacqua, L; Pepé-Altarelli, M; Curtis, L; Dorris, S J; Halley, A W; Knowles, I G; Lynch, J G; O'Shea, V; Raine, C; Scarr, J M; Smith, K; Teixeira-Dias, P; Thompson, A S; Thomson, E; Thomson, F; Turnbull, R M; Geweniger, C; Graefe, G; Hanke, P; Hansper, G; Hepp, V; Kluge, E E; Putzer, A; Schmidt, M; Sommer, J; Tittel, K; Werner, S; Wunsch, M; Beuselinck, R; Binnie, David M; Cameron, W; Dornan, Peter J; Girone, M; Goodsir, S M; Martin, E B; Moutoussi, A; Nash, J; Sedgbeer, J K; Stacey, A M; Williams, M D; Dissertori, G; Girtler, P; Kuhn, D; Rudolph, G; Betteridge, A P; Bowdery, C K; Colrain, P; Crawford, G; Finch, A J; Foster, F; Hughes, G; Sloan, Terence; Williams, M I; Galla, A; Giehl, I; Greene, A M; Hoffmann, C; Jakobs, K; Kleinknecht, K; Quast, G; Renk, B; Rohne, E; Sander, H G; Van Gemmeren, P; Zeitnitz, C; Aubert, Jean-Jacques; Benchouk, C; Bonissent, A; Bujosa, G; Calvet, D; Carr, J; Coyle, P; Diaconu, C A; Etienne, F; Konstantinidis, N P; Leroy, O; Motsch, F; Payre, P; Rousseau, D; Talby, M; Sadouki, A; Thulasidas, M; Trabelsi, K; Aleppo, M; Ragusa, F; Berlich, R; Blum, Walter; Büscher, V; Dietl, H; Dydak, Friedrich; Ganis, G; Gotzhein, C; Kroha, H; Lütjens, G; Lutz, Gerhard; Männer, W; Moser, H G; Richter, R H; Rosado-Schlosser, A; Schael, S; Settles, Ronald; Seywerd, H C J; Saint-Denis, R; Stenzel, H; Wiedenmann, W; Wolf, G; Boucrot, J; Callot, O; Chen, S; Choi, Y; Cordier, A; Davier, M; Duflot, L; Grivaz, J F; Heusse, P; Höcker, A; Jacholkowska, A; Jacquet, M; Kim, D W; Le Diberder, F R; Lefrançois, J; Lutz, A M; Nikolic, I A; Schune, M H; Simion, S; Tournefier, E; Veillet, J J; Videau, I; Zerwas, D; Azzurri, P; Bagliesi, G; Batignani, G; Bettarini, S; Bozzi, C; Calderini, G; Carpinelli, M; Ciocci, M A; Ciulli, V; Dell'Orso, R; Fantechi, R; Ferrante, I; Foà, L; Forti, F; Giassi, A; Giorgi, M A; Gregorio, A; Ligabue, F; Lusiani, A; Marrocchesi, P S; Messineo, A; Palla, Fabrizio; Sanguinetti, G; Sciabà, A; Spagnolo, P; Steinberger, Jack; Tenchini, Roberto; Tonelli, G; Vannini, C; Venturi, A; Verdini, P G; Blair, G A; Bryant, L M; Chambers, J T; Gao, Y; Green, M G; Medcalf, T; Perrodo, P; Strong, J A; Von Wimmersperg-Töller, J H; Botterill, David R; Clifft, R W; Edgecock, T R; Haywood, S; Maley, P; Norton, P R; Thompson, J C; Wright, A E; Bloch-Devaux, B; Colas, P; Emery, S; Kozanecki, Witold; Lançon, E; Lemaire, M C; Locci, E; Pérez, P; Rander, J; Renardy, J F; Roussarie, A; Schuller, J P; Schwindling, J; Trabelsi, A; Vallage, B; Black, S N; Dann, J H; Johnson, R P; Kim, H Y; Litke, A M; McNeil, M A; Taylor, G; Booth, C N; Boswell, R; Brew, C A J; Cartwright, S L; Combley, F; Kelly, M S; Lehto, M H; Newton, W M; Reeve, J; Thompson, L F; Böhrer, A; Brandt, S; Cowan, G D; Grupen, Claus; Saraiva, P; Smolik, L; Stephan, F; Apollonio, M; Bosisio, L; Della Marina, R; Giannini, G; Gobbo, B; Musolino, G; Rothberg, J E; Wasserbaech, S R; Armstrong, S R; Charles, E; Elmer, P; Ferguson, D P S; Gao, Y S; González, S; Greening, T C; Hayes, O J; Hu, H; Jin, S; McNamara, P A; Nachtman, J M; Nielsen, J; Orejudos, W; Pan, Y B; Saadi, Y; Scott, I J; Walsh, J; Wu Sau Lan; Wu, X; Yamartino, J M; Zobernig, G

    1997-01-01

    A measurement of the spectral functions of non-strange tau vector current final states is presented, using 124,358 tau pairs recorded by the ALEPH detector at LEP during the years 1991 to 1994. The spectral functions of the dominant two- and four-pion tau decay channels are compared to published results of e+e- annihilation experiments via isospin rotation. A combined fit of the pion form factor from tau decays and e+e- data is performed using different parametrizations. The mass and the width of the charged and the neutral rho(770) are separately determined in order to extract possible isospin violating effects. The mass and width differences are measured to be M(rho^+/-(770)) - M(rho^0(770)) = (0.0 +/- 1.0) MeV/c^2 and Gamma(rho^+/-(770)) - Gamma(rho^0(770)) = (0.1 +/- 1.9) MeV/c^2.

  12. Ocean currents and acoustic backscatter data from shipboard ADCP measurements at three North Atlantic seamounts between 2004 and 2015.

    Science.gov (United States)

    Mohn, Christian; Denda, Anneke; Christiansen, Svenja; Kaufmann, Manfred; Peine, Florian; Springer, Barbara; Turnewitsch, Robert; Christiansen, Bernd

    2018-04-01

    Seamounts are amongst the most common physiographic structures of the deep-ocean landscape, but remoteness and geographic complexity have limited the systematic collection of integrated and multidisciplinary data in the past. Consequently, important aspects of seamount ecology and dynamics remain poorly studied. We present a data collection of ocean currents and raw acoustic backscatter from shipboard Acoustic Doppler Current Profiler (ADCP) measurements during six cruises between 2004 and 2015 in the tropical and subtropical Northeast Atlantic to narrow this gap. Measurements were conducted at seamount locations between the island of Madeira and the Portuguese mainland (Ampère, Seine Seamount), as well as east of the Cape Verde archipelago (Senghor Seamount). The dataset includes two-minute ensemble averaged continuous velocity and backscatter profiles, supplemented by spatially gridded maps for each velocity component, error velocity and local bathymetry. The dataset is freely available from the digital data library PANGAEA at https://doi.pangaea.de/10.1594/PANGAEA.883193.

  13. Study of transient current induced by heavy-ion microbeams in Si and GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Hirao, Toshio; Nashiyama, Isamu; Kamiya, Tomihiro; Suda, Tamotu [Japan Atomic Energy Research Inst., Takasaki, Gunma (Japan). Takasaki Radiation Chemistry Research Establishment

    1997-03-01

    Heavy-ion microbeams were applied to the study of mechanism of single event upset (SEU). Transient current induced in p{sup +}n junction diodes by strike of heavy ion microbeam were measured by using a high-speed digitizing sampling system. (author)

  14. Experimental study of blockage of monochromatic waves by counter currents

    NARCIS (Netherlands)

    Suastika, I.K.

    1999-01-01

    Blockage of waves by a current can occur if waves are propagating on a spatially varying opposing current in which the velocity is increasing in the wave propagation direction. The ongoing waves become shorter and steeper while they are propagating against the current. Blocking occurs at the

  15. Reconstruction of the ion plasma parameters from the current measurements: mathematical tool

    Directory of Open Access Journals (Sweden)

    E. Séran

    Full Text Available Instrument d’Analyse du Plasma (IAP is one of the instruments of the newly prepared ionospheric mission Demeter. This analyser was developed to measure flows of thermal ions at the altitude of ~ 750 km and consists of two parts: (i retarding potential analyser (APR, which is utilised to measure the energy distribution of the ion plasma along the sensor look direction, and (ii velocity direction analyser (ADV, which is used to measure the arrival angle of the ion flow with respect to the analyser axis. The necessity to obtain quick and precise estimates of the ion plasma parameters has prompted us to revise the existing mathematical tool and to investigate different instrumental limitations, such as (i finite angular aperture, (ii grid transparency, (iii potential depression in the space between the grid wires, (iv losses of ions during their passage between the entrance diaphragm and the collector. Simple analytical expressions are found to fit the currents, which are measured by the APR and ADV collectors, and show a very good agreement with the numerical solutions. It was proven that the fitting of the current with the model functions gives a possibility to properly resolve even minor ion concentrations and to find the arrival angles of the ion flow in the multi-species plasma. The discussion is illustrated by an analysis of the instrument response in the ionospheric conditions which are predicted by the International Reference Ionosphere (IRI model.

    Key words. Ionosphere (plasma convection; instruments and techniques – Space plasma physics (experimental and mathematical techniques

  16. Reconstruction of the ion plasma parameters from the current measurements: mathematical tool

    Directory of Open Access Journals (Sweden)

    E. Séran

    2003-05-01

    Full Text Available Instrument d’Analyse du Plasma (IAP is one of the instruments of the newly prepared ionospheric mission Demeter. This analyser was developed to measure flows of thermal ions at the altitude of ~ 750 km and consists of two parts: (i retarding potential analyser (APR, which is utilised to measure the energy distribution of the ion plasma along the sensor look direction, and (ii velocity direction analyser (ADV, which is used to measure the arrival angle of the ion flow with respect to the analyser axis. The necessity to obtain quick and precise estimates of the ion plasma parameters has prompted us to revise the existing mathematical tool and to investigate different instrumental limitations, such as (i finite angular aperture, (ii grid transparency, (iii potential depression in the space between the grid wires, (iv losses of ions during their passage between the entrance diaphragm and the collector. Simple analytical expressions are found to fit the currents, which are measured by the APR and ADV collectors, and show a very good agreement with the numerical solutions. It was proven that the fitting of the current with the model functions gives a possibility to properly resolve even minor ion concentrations and to find the arrival angles of the ion flow in the multi-species plasma. The discussion is illustrated by an analysis of the instrument response in the ionospheric conditions which are predicted by the International Reference Ionosphere (IRI model.Key words. Ionosphere (plasma convection; instruments and techniques – Space plasma physics (experimental and mathematical techniques

  17. Contamination of current-clamp measurement of neuron capacitance by voltage-dependent phenomena

    Science.gov (United States)

    White, William E.

    2013-01-01

    Measuring neuron capacitance is important for morphological description, conductance characterization, and neuron modeling. One method to estimate capacitance is to inject current pulses into a neuron and fit the resulting changes in membrane potential with multiple exponentials; if the neuron is purely passive, the amplitude and time constant of the slowest exponential give neuron capacitance (Major G, Evans JD, Jack JJ. Biophys J 65: 423–449, 1993). Golowasch et al. (Golowasch J, Thomas G, Taylor AL, Patel A, Pineda A, Khalil C, Nadim F. J Neurophysiol 102: 2161–2175, 2009) have shown that this is the best method for measuring the capacitance of nonisopotential (i.e., most) neurons. However, prior work has not tested for, or examined how much error would be introduced by, slow voltage-dependent phenomena possibly present at the membrane potentials typically used in such work. We investigated this issue in lobster (Panulirus interruptus) stomatogastric neurons by performing current clamp-based capacitance measurements at multiple membrane potentials. A slow, voltage-dependent phenomenon consistent with residual voltage-dependent conductances was present at all tested membrane potentials (−95 to −35 mV). This phenomenon was the slowest component of the neuron's voltage response, and failure to recognize and exclude it would lead to capacitance overestimates of several hundredfold. Most methods of estimating capacitance depend on the absence of voltage-dependent phenomena. Our demonstration that such phenomena make nonnegligible contributions to neuron responses even at well-hyperpolarized membrane potentials highlights the critical importance of checking for such phenomena in all work measuring neuron capacitance. We show here how to identify such phenomena and minimize their contaminating influence. PMID:23576698

  18. CURRENT STUDY ON THE FUNDING SOURCES COVERAGE OF CURRENT ASSETS TO COMPANIES LISTED ON THE BUCHAREST STOCK EXCHANGE

    Directory of Open Access Journals (Sweden)

    Teodor HADA

    2014-06-01

    Full Text Available This paper presents issues about the coverage with financing sources of current assets for 64 companies listed on the Bucharest Stock Exchange. The aim of the study is to see how to calculate indicators specific to current assets and the general framework offered as whole analysis of the financing sources of current assets. The introduction of the paper presents the objective, the research methodology and the novelties brought by this study. Further on, this study shows the various views of the authors about the concept of "current assets", financing sources of current assets, the calculation of net working capital, setting the limits of the normal working capital and determining the speed of rotation. After that was done, based on the theory, a case study was performed, for companies covered in this study. Conclusions focused on determining the final data about what was detailed in the previous paragraphs.

  19. Measuring quality of life in cleft lip and palate patients: currently available patient-reported outcomes measures.

    Science.gov (United States)

    Eckstein, Donna A; Wu, Rebecca L; Akinbiyi, Takintope; Silver, Lester; Taub, Peter J

    2011-11-01

    Patient-reported outcomes in cleft lip and palate treatment are critical for patient care. Traditional surgical outcomes focused on objective measures, such as photographs, anatomic measurements, morbidity, and mortality. Although these remain important, they leave many questions unanswered. Surveys that include aesthetics, speech, functionality, self-image, and quality of life provide more thorough outcomes assessment. It is vital that reliable, valid, and comprehensive questionnaires are available to craniofacial surgeons. The authors performed a literature review to identify questionnaires validated in cleft lip and palate patients. Qualifying instruments were assessed for adherence to guidelines for development and validation by the scientific advisory committee and for content. The authors identified 44 measures used in cleft lip and palate studies. After 15 ad hoc questionnaires, eight generic instruments, 11 psychiatric instruments, and one non-English language questionnaire were excluded, nine measures remained. Of these, four were never validated in the cleft population. Analysis revealed one craniofacial-specific measure (Youth Quality of Life-Facial Differences), two voice-related measures (Patient Voice-Related Quality of Life and Cleft Audit Protocol for Speech-Augmented), and two oral health-related measures (Child Oral Health Impact Profile and Child Oral Health Quality of Life). The Youth Quality of Life-Facial Differences, Child Oral Health Impact Profile, and Child Oral Health Quality of Life questionnaires were sufficiently validated. None was created specifically for clefts, resulting in content limitations. There is a lack of comprehensive, valid, and reliable questionnaires for cleft lip and palate surgery. For thorough assessment of satisfaction, further research to develop and validate cleft lip and palate surgery-specific instruments is needed.

  20. Current status of thermoluminescence studies on minerals and rocks

    International Nuclear Information System (INIS)

    Sankaran, A.V.; Nambi, K.S.V.; Sunta, C.M.

    1982-01-01

    The usefulness of thermoluminescence (TL) in geological studies is being increasingly recognized, as may be judged from the considerable volume of literature accumulated over the past couple of decades; besides, a number of seminars, conferences and specialists' meetings have also been held on the subject of applied TL. However, these publications lie scattered over several periodicals and conference proceedings and an interested worker finds it difficult to obtain the gist of the contributions in one place. The present authors felt a need for this and have, therefore, attempted to bring together in this Report the current status of TL research about different minerals; applications in the fields of geochronology, ore-prospecting, stratigraphic correlation, geothermometry and other useful areas are also included. (author)

  1. Measurement of Neutral-Current K+ Production by Neutrinos using MINERvA

    Science.gov (United States)

    Marshall, C. M.; Aliaga, L.; Altinok, O.; Bellantoni, L.; Bercellie, A.; Betancourt, M.; Bodek, A.; Bravar, A.; Cai, T.; Carneiro, M. F.; da Motta, H.; Dytman, S. A.; Díaz, G. A.; Dunkman, M.; Eberly, B.; Endress, E.; Felix, J.; Fields, L.; Fine, R.; Gago, A. M.; Galindo, R.; Gallagher, H.; Ghosh, A.; Golan, T.; Gran, R.; Harris, D. A.; Higuera, A.; Hurtado, K.; Kleykamp, J.; Kordosky, M.; Le, T.; Maher, E.; Manly, S.; Mann, W. A.; Caicedo, D. A. Martinez; McFarland, K. S.; McGivern, C. L.; McGowan, A. M.; Messerly, B.; Miller, J.; Mislivec, A.; Morfín, J. G.; Mousseau, J.; Naples, D.; Nelson, J. K.; Norrick, A.; Nuruzzaman; Paolone, V.; Patrick, C. E.; Perdue, G. N.; Ramírez, M. A.; Ransome, R. D.; Ray, H.; Ren, L.; Rimal, D.; Rodrigues, P. A.; Ruterbories, D.; Schmitz, D. W.; Solano Salinas, C. J.; Sultana, M.; Sánchez Falero, S.; Valencia, E.; Walton, T.; Wolcott, J.; Wospakrik, M.; Yaeggy, B.; Zhang, D.; Minerva Collaboration

    2017-07-01

    Neutral-current production of K+ by atmospheric neutrinos is a background in searches for the proton decay p →K+ν ¯. Reactions such as ν p →ν K+Λ are indistinguishable from proton decays when the decay products of the Λ are below detection threshold. Events with K+ are identified in MINERvA by reconstructing the timing signature of a K+ decay at rest. A sample of 201 neutrino-induced neutral-current K+ events is used to measure differential cross sections with respect to the K+ kinetic energy, and the non-K+ hadronic visible energy. An excess of events at low hadronic visible energy is observed relative to the prediction of the neut event generator. Good agreement is observed with the cross section prediction of the genie generator. A search for photons from π0 decay, which would veto a neutral-current K+ event in a proton decay search, is performed, and a 2 σ deficit of detached photons is observed relative to the genie prediction.

  2. Temperature and current dependent electroluminescence measurements on colour-coded multiple quantum well light emitting diodes

    Energy Technology Data Exchange (ETDEWEB)

    Bergbauer, Werner [OSRAM Opto Semiconductors GmbH, Regensburg (Germany); FH Deggendorf (Germany); Laubsch, Ansgar; Peter, Matthias; Mayer, Tobias; Bader, Stefan; Oberschmid, Raimund; Hahn, Berthold [OSRAM Opto Semiconductors GmbH, Regensburg (Germany); Benstetter, Guenther [FH Deggendorf (Germany)

    2008-07-01

    As the efficiency and the luminous flux have been increased enormously in the last few years, today Light Emitting Diodes (LEDs) are even pushed to applications like general lighting and Home Cinema Projection. Still, InGaN/GaN heterostructure based LEDs suffer from loss-mechanisms like non-radiative defect and Auger recombination, carrier leakage and piezo-field induced carrier separation. To optimize the high current efficiency we evaluated the benefit of Multiple Quantum Well (MQW) compared to Single Quantum Well (SQW) LEDs. Temperature dependent electroluminescence of colour-coded structures with different Indium content in certain Quantum Wells was measured. The experiments demonstrated a strong temperature and current dependence of the MQW operation. The comparison between different LED structures showed effectively the increased LED performance of those structures which operate with a well adjusted MQW active area. Due to the enhanced carrier distribution in the high current range, these LEDs show a higher light output and additionally a reduced wavelength shift.

  3. Temperature and current dependent electroluminescence measurements on colour-coded multiple quantum well light emitting diodes

    International Nuclear Information System (INIS)

    Bergbauer, Werner; Laubsch, Ansgar; Peter, Matthias; Mayer, Tobias; Bader, Stefan; Oberschmid, Raimund; Hahn, Berthold; Benstetter, Guenther

    2008-01-01

    As the efficiency and the luminous flux have been increased enormously in the last few years, today Light Emitting Diodes (LEDs) are even pushed to applications like general lighting and Home Cinema Projection. Still, InGaN/GaN heterostructure based LEDs suffer from loss-mechanisms like non-radiative defect and Auger recombination, carrier leakage and piezo-field induced carrier separation. To optimize the high current efficiency we evaluated the benefit of Multiple Quantum Well (MQW) compared to Single Quantum Well (SQW) LEDs. Temperature dependent electroluminescence of colour-coded structures with different Indium content in certain Quantum Wells was measured. The experiments demonstrated a strong temperature and current dependence of the MQW operation. The comparison between different LED structures showed effectively the increased LED performance of those structures which operate with a well adjusted MQW active area. Due to the enhanced carrier distribution in the high current range, these LEDs show a higher light output and additionally a reduced wavelength shift

  4. Calorimetric method for current sharing temperature measurements in ITER conductor samples in SULTAN

    International Nuclear Information System (INIS)

    Bagnasco, M.

    2009-01-01

    Several Toroidal Field Conductor short samples with slight layout variations have been assembled and tested in the SULTAN facility at CRPP. The measurement campaigns started in 2007 and are still ongoing. The performance of every conductor is expressed in terms of current sharing temperature (T cs ), i.e. the temperature at which a defined electric field, 10 μV/m, is detected in the cable due to the incipient superconducting-to-normal state transition. The T cs at specific operating conditions is the key design parameter for the ITER conductors and is the main object of the qualification tests. Typically, the average electric field is measured with voltage tap pairs attached on the jacket along the conductor. The inability however to explain observed premature voltage developments opened the discussion about possible alternative measuring methods. The He flow calorimetric method is based on the measurement of the resistive power generation in the conductor. It relies on the detection of very small temperature increases along the conductor in steady state operation. The accuracy and the reliability of the calorimetric method in SULTAN are critically discussed, with particular emphasis on the instrumentation requirements and test procedures. The application of the calorimetric method to the recent SULTAN test campaigns is described with its merits and limits. For future tests of ITER conductors in SULTAN, the calorimetric method for T cs test is proposed as a routine procedure.

  5. A Linear Birefringence Measurement Method for an Optical Fiber Current Sensor.

    Science.gov (United States)

    Xu, Shaoyi; Shao, Haiming; Li, Chuansheng; Xing, Fangfang; Wang, Yuqiao; Li, Wei

    2017-07-03

    In this work, a linear birefringence measurement method is proposed for an optical fiber current sensor (OFCS). First, the optical configuration of the measurement system is presented. Then, the elimination method of the effect of the azimuth angles between the sensing fiber and the two polarizers is demonstrated. Moreover, the relationship of the linear birefringence, the Faraday rotation angle and the final output is determined. On these bases, the multi-valued problem on the linear birefringence is simulated and its solution is illustrated when the linear birefringence is unknown. Finally, the experiments are conducted to prove the feasibility of the proposed method. When the numbers of turns of the sensing fiber in the OFCS are about 15, 19, 23, 27, 31, 35, and 39, the measured linear birefringence obtained by the proposed method are about 1.3577, 1.8425, 2.0983, 2.5914, 2.7891, 3.2003 and 3.5198 rad. Two typical methods provide the references for the proposed method. The proposed method is proven to be suitable for the linear birefringence measurement in the full range without the limitation that the linear birefringence must be smaller than π/2.

  6. Methods for Specific Electrode Resistance Measurement during Transcranial Direct Current Stimulation

    Science.gov (United States)

    Khadka, Niranjan; Rahman, Asif; Sarantos, Chris; Truong, Dennis Q.; Bikson, Marom

    2014-01-01

    Background Transcranial Direct Current Stimulation (tDCS) is investigated to treat a wide range of neuropsychiatric disorders, for rehabilitation, and for enhancing cognitive performance. The monitoring of electrode resistance before and during tDCS is considered important for tolerability and safety, where an unusually high resistance is indicative of undesired electrode or poor skin contact conditions. Conventional resistance measurement methods do not isolate individual electrode resistance but rather measures overall voltage. Moreover, for HD-tDCS devices, cross talk across electrodes makes concurrent resistance monitoring unreliable. Objective We propose a novel method for monitoring of the individual electrode resistance during tDCS, using a super-position of direct current with a test-signal (low-intensity and low-frequency sinusoids with electrode– specific frequencies) and a single sentinel electrode (not used for DC). Methods To validate this methodology, we developed lumped-parameter models of two and multi-electrode tDCS. Approaches with and without a sentinel electrode were solved and underlying assumptions identified. Assumptions were tested and parameterized in healthy participants using forearm stimulation combining tDCS (2 mA) and sinusoidal test-signals (38 μA and 76 μA peak to peak at 1 Hz, 10 Hz, and 100 Hz) and an in vitro test (where varied electrode failure modes were created). DC and AC component voltages across the electrodes were compared and participants were asked to rate subjective pain. Results A sentinel electrode is required to isolate electrode resistance in a two-electrode tDCS system. For multi-electrode resistance tracking, cross talk was aggravated with electrode proximity and current/resistance mismatches, but could be corrected using proposed approaches. Average voltage and average pain scores were not significantly different across test current intensities and frequencies (two-way repeated measures ANOVA) indicating the

  7. In situ beam angle measurement in a multi-wafer high current ion implanter

    International Nuclear Information System (INIS)

    Freer, B.S.; Reece, R.N.; Graf, M.A.; Parrill, T.; Polner, D.

    2005-01-01

    Direct, in situ measurement of the average angle and angular content of an ion beam in a multi-wafer ion implanter is reported for the first time. A new type of structure and method are described. The structures are located on the spinning disk, allowing precise angular alignment to the wafers. Current that passes through the structures is known to be within a range of angles and is detected behind the disk. By varying the angle of the disk around two axes, beam current versus angle is mapped and the average angle and angular spread are calculated. The average angle measured in this way is found to be consistent with that obtained by other techniques, including beam centroid offset and wafer channeling methods. Average angle of low energy beams, for which it is difficult to use other direct methods, is explored. A 'pencil beam' system is shown to give average angle repeatability of 0.13 deg. (1σ) or less, for two low energy beams under normal tuning variations, even though no effort was made to control the angle

  8. Measurement of fatigue crack growth using low-profile eddy-current sensors

    International Nuclear Information System (INIS)

    Ditchburn, R.J.; Ibrahim, M.E.; Burke, S.K.

    2011-01-01

    Conformable spiral coils show promise as permanently mounted eddy-current sensors for the detection and monitoring of surface-breaking cracks in electrically conductive structures. Flexibility and a low profile (typically less than 0.5 mm) are key advantages that allow the sensors to be unobtrusively mounted on curved surfaces and beneath surface coatings. Furthermore, these sensors can be permanently mounted in areas that would otherwise be difficult or impossible to reach without significant disassembly. The sensors can be activated and interrogated using the same well-established electromagnetic measurement principles in eddy-current nondestructive inspection. A material test machine was used to grow through-thickness fatigue crack in a compact-tension specimen made from the aerospace-grade aluminium alloy AA2014. The growth of the crack was examined by measuring the small impedance changes of planar spiral-coil sensors attached to the specimen. The results indicate that permanently attached conformable spiral coils can be used to detect a deep crack once it has grown beneath the sensor, and then to monitor subsequent crack growth.

  9. Characterization of transient discharges under atmospheric-pressure conditions applying nitrogen photoemission and current measurements

    International Nuclear Information System (INIS)

    Keller, Sandra; Rajasekaran, Priyadarshini; Bibinov, Nikita; Awakowicz, Peter

    2012-01-01

    The plasma parameters such as electron distribution function and electron density of three atmospheric-pressure transient discharges namely filamentary and homogeneous dielectric barrier discharges in air, and the spark discharge of an argon plasma coagulation (APC) system are determined. A combination of numerical simulation as well as diagnostic methods including current measurement and optical emission spectroscopy (OES) based on nitrogen emissions is used. The applied methods supplement each other and resolve problems, which arise when these methods are used individually. Nitrogen is used as a sensor gas and is admixed in low amount to argon for characterizing the APC discharge. Both direct and stepwise electron-impact excitation of nitrogen emissions are included in the plasma-chemical model applied for characterization of these transient discharges using OES where ambiguity arises in the determination of plasma parameters under specific discharge conditions. It is shown that the measured current solves this problem by providing additional information useful for the determination of discharge-specific plasma parameters. (paper)

  10. Studies of micromorphology and current efficiency of zinc electrodeposited from flowing chloride electrolytes

    Energy Technology Data Exchange (ETDEWEB)

    Mc Vay, Laura [Univ. of California, Berkeley, CA (United States); Muller, Rolf H. [Univ. of California, Berkeley, CA (United States); Tobias, Charles W. [Univ. of California, Berkeley, CA (United States)

    1986-05-01

    Results of a study of the micromorphology and current efficiency of zinc electrodeposited from flowing, acidic chloride solutions are reported. The effects of six variables were examined: flow rate, current density, zinc and hydrogen ion concentration, concentrations of nickel, iron and cadmium impurity ions, and the nature of the substrate. The development of micromorphology was studied in-situ by means of videomicrography and ex-situ by means of scanning electron microscopy. This investigation focused on the formation of grooved deposits, which are found under a wide range of deposition conditions. The major conclusions of this study are: the most important variable determining whether grooved deposits form is the interfacial concentration; large protrusions orient themselves parallel to the flow direction with the orientation starting upstream and progressing downstream; large protrusions become ridges due to growth of the highest current density portions of the electrode under mass transport control. The current efficiency was measured using EDTA titration and weight measurements. The fraction of the current taken by zinc deposition increased with zinc concentration, ranging up to 100%, and decreased with pH. The efficiency of zinc deposition was affected by the flow rate and the substrate employed. Impurities lowered the current efficiency.

  11. Current use and barriers and facilitators for implementation of standardised measures in physical therapy in the Netherlands

    Directory of Open Access Journals (Sweden)

    Wittink Harriet

    2011-05-01

    Full Text Available Abstract Background In many countries, the need for physical therapists to use standardised measures has been recognised and is recommended in clinical practice guidelines. Research has shown a lack of clinimetric knowledge and clinical application of measurement instruments in daily practice may hamper implementation of these guidelines. Objectives The aims of our study were a to investigate the current use of measurement instruments by Dutch physical therapists; b to investigate the facilitators and barriers in using measurement instruments. Methods To get a complete and valid overview of relevant barriers and facilitators, different methods of data collection were used. We conducted a literature search, semi-structured interviews with 20 physical therapists and an online survey. Results Facilitators are the fact that most therapists indicated a positive attitude and were convinced of the advantages of the use of measurement instruments. The most important barriers to the use of measurement instruments included physical therapists' competence and problems in changing behaviour, practice organisation (no room; no time and the unavailability and feasibility of measurement instruments. Furthermore, physical therapists indicated the need to have a core set of measurement instruments with a short user's instruction on application, scoring and interpretation. Conclusions The main barriers are on the level of the physical therapist (lack of knowledge; not focusing on the use of outcome measures and organisation (lack of time; availability; lack of management support. There seems to be a disparity between what physical therapists say and what they do. The majority of participating physical therapists indicated a positive attitude and were convinced of the advantages of the use of measurement instruments. However, the main problem for physical therapists is when to use which instrument for what patient (lack of knowledge. Furthermore, physical

  12. A method for measuring the inductive electric field profile and noninductive current profiles on DIII-D

    International Nuclear Information System (INIS)

    Forest, C.B.; Luce, T.C.; Politzer, P.A.; Lao, L.L.; Kupfer, K.; Wroblewski, D.

    1994-07-01

    A new technique for determining the parallel electric field profile and noninductive current profile in tokamak plasmas has been developed and applied to two DIII-D tokamak discharges. Central to this technique is the determination of the current density profile, J(ρ), and poloidal flux, ψ(ρ), from equilibrium reconstructions. From time sequences of the reconstructions, the flux surface averaged, parallel electric field can be estimated from appropriate derivatives of the poloidal flux. With a model for the conductivity and measurements of T e and Z eff , the noninductive fraction of the current can be determined. Such a technique gives the possibility of measuring directly the bootstrap current profile and the noninductively driven current from auxiliary heating such as neutral beam injection or fast wave current drive. Furthermore, if the noninductively driven current is small or if the noninductive current profile is assumed to be known, this measurement provides a local test of the conductivity model under various conditions

  13. The current status of glass leaching studies in France

    International Nuclear Information System (INIS)

    Laude, F.

    1983-11-01

    Glass has been selected in France as the material used to confine the activity of fission product solutions, and a continuous vitrification process has been developed at the Marcoule Vitrification Facility (AVM), the first industrial plant. Borosilicate glass was chosen in various compositions for its properties: it is a homogeneous, non-porous material that incorporates appreciable quantities of most of the fission product oxides, and is only alterable at the surface interface layer. Glass thus constitutes the primary radioactivity containment barrier, and it is essential to determine its long-term behavior. Water constitutes the principal hazard during temporary or definitive storage of the glass blocks. Two types of inherent material properties are studied from the standpoint of glass stability under leaching conditions: - chemical durability; - radioactive containability with regard to the various radionuclides, fission products and especially the actinides. Durability tests are carried out in SOXHLET devices and the alteration rates are measured by the weight loss. The containability is measured by the leach rate, i.e. by the rate of activity loss into the water. Leaching tests are conducted for several major objectives: - selection of glass compositions (leach rates); - leaching mechanism studies (hydrolyzed layer characteristics, effects of temperature, pressure, pH, etc.); - long-term behavior studies (glass specimens doped with alpha-emitters); - simulation of geological repository environments [fr

  14. Measuring University Students' Approaches to Learning Statistics: An Invariance Study

    Science.gov (United States)

    Chiesi, Francesca; Primi, Caterina; Bilgin, Ayse Aysin; Lopez, Maria Virginia; del Carmen Fabrizio, Maria; Gozlu, Sitki; Tuan, Nguyen Minh

    2016-01-01

    The aim of the current study was to provide evidence that an abbreviated version of the Approaches and Study Skills Inventory for Students (ASSIST) was invariant across different languages and educational contexts in measuring university students' learning approaches to statistics. Data were collected on samples of university students attending…

  15. Wind-Forced Modeling Studies of Currents, Meanders, Eddies, and Filaments of the Canary Current System

    Science.gov (United States)

    1997-06-01

    infra-red images from NOAA7 and NOAA9 and numerous in- situ measurements reveal the existence of a surface poleward flow off the northern coast of...dinamica das Aguas costeiras de Portugal. Dissertacao apresentada a Universidade de Lisboa para obtencao do grau de Doutor em Fisica, especializacao

  16. Dark Current And Voltage Measurements Of Metal-Organic-Semiconductor (M-Or-S) Diode

    International Nuclear Information System (INIS)

    Adianto

    1996-01-01

    . Some Metal-Organic-Semiconductor (M-Or-S) thin film diodes, constructed with an organic polymer (polymerized toluene) as an active component has been successfully fabricated. The thin film M-Or-S diodes were fabricated on an n-type silicon with resistivity of 250-500 Ocm and p type silicon with resistivity of 10-20 Ocm as a substrate with polymerized toluene used as insulator. When deposited on silicon wafers with electrode of evaporated Ni on the n-type silicon and evaporated Au as the electrode on the polymerized toluene film, the electronic devices of Metal-Organic- Semiconductor (M-Or-S) type can be produced with one of its characteristics is that their light sensitivity. A plasma ion deposition system was constructed and used to deposit organic monomeric substance (toluene) that functioned as an isolator between semiconductor and the evaporated metal electrodes. The current-voltage measurements for different configurations of M-Or-S devices were carried out to determine the current-voltage (1-V) characteristics for M-Or-S devices with different materials and thicknesses. In addition to the 1-V measurement mentioned before, 1-V measurements of the devices were also carried out by using a curve tracer oscilloscope, and the picture of the effective parameters of each of the device could be taken by using a polaroid camera. Since the devices are very sensitive to light, the devices were all tested in a black-box which was covered by a black cloth to make sure that there was no light coming through. The experimental results for p- and n-type silicon substrates showed that an M-Or-S diode with n-type gave a higher breakdown voltage than that p- type silicon. In addition, the reverse bias breakdown voltage increased as the thickness of the thin film increased in the range of 50 -2500 V/μm

  17. Amplifier spurious input current components in electrode-electrolyte interface impedance measurements

    Directory of Open Access Journals (Sweden)

    Madrid Rossana E

    2005-03-01

    Full Text Available Abstract Background In Impedance Microbiology, the time during which the measuring equipment is connected to the bipolar cells is rather long, usually between 6 to 24 hrs for microorganisms with duplication times in the order of less than one hour and concentrations ranging from 101 to 107 [CFU/ml]. Under these conditions, the electrode-electrolyte interface impedance may show a slow drift of about 2%/hr. By and large, growth curves superimposed on such drift do not stabilize, are less reproducible, and keep on distorting all over the measurement of the temporal reactive or resistive records due to interface changes, in turn originated in bacterial activity. This problem has been found when growth curves were obtained by means of impedance analyzers or with impedance bridges using different types of operational amplifiers. Methods Suspecting that the input circuitry was the culprit of the deleterious effect, we used for that matter (a ultra-low bias current amplifiers, (b isolating relays for the selection of cells, and (c a shorter connection time, so that the relays were maintained opened after the readings, to bring down such spurious drift to a negligible value. Bacterial growth curves were obtained in order to test their quality. Results It was demonstrated that the drift decreases ten fold when the circuit remained connected to the cell for a short time between measurements, so that the distortion became truly negligible. Improvement due to better-input amplifiers was not as good as by reducing the connection time. Moreover, temperature effects were insignificant with a regulation of ± 0.2 [°C]. Frequency did not influence either. Conclusion The drift originated either at the dc input bias offset current (Ios of the integrated circuits, or in discrete transistors connected directly to the electrodes immersed in the cells, depending on the particular circuit arrangement. Reduction of the connection time was the best countermeasure.

  18. Current status of crushed rock and whole rock column studies

    International Nuclear Information System (INIS)

    Vine, E.N.; Daniels, W.R.; Rundberg, R.S.; Thompson, J.L.

    1980-01-01

    Measurements on a large number of crushed rock columns of tuff, granite, and argillite are discussed. The isotopes 85 Sr, 137 Cs, 133 Ba, 141 Ce, 152 Eu, /sup 95m/Tc, and 233 U were used. Flow rates were varied from approx. 30 to approx. 30000 m/y. Other parameters studied include isotope concentration and atmosphere. The sorption ratios calculated were compared with batch sorption ratios on the same samples. Methods of studying the movement of radionuclides through whole rock cores are described. The problems associated with sealing the cores to prevent leaking along the exterior surface and one possible solution are discussed. The strontium sorption ratio obtained by elution of one solid tuff core is compared with the batch and crushed rock column sorption ratios

  19. Measurement of Charged Current Coherent Pion Production by Neutrinos on Carbon at MINER$\

    Energy Technology Data Exchange (ETDEWEB)

    Mislivec, Aaron Robert [Univ. of Rochester, NY (United States)

    2017-01-01

    Neutrino-nucleus coherent pion production is a rare neutrino scattering process where the squared four-momentum transferred to the nucleus is small, a lepton and pion are produced in the forward direction, and the nucleus remains in its initial state. This process is an important background in neutrino oscillation experiments. Measurements of coherent pion production are needed to constrain models which are used to predict coherent pion production in oscillation experiments. This thesis reports measurements of νµ and νµ charged current coherent pion production on carbon for neutrino energies in the range 2 < Eν < 20 GeV. The measurements were made using data from MINERνA, which is a dedicated neutrino-nucleus scattering experiment that uses a fi scintillator tracking detector in the high-intensity NuMI neutrino beam at Fermilab. Coherent interactions were isolated from the data using only model-independent signatures of the reaction, which are a forward muon and pion, no evidence of nuclear breakup, and small four-momentum transfer to the nucleus. The measurements were compared to the coherent pion production model used by oscillation experiments. The data and model agree in the total interaction rate and are similar in the dependence of the interaction rate on the squared four- momentum transferred from the neutrino. The data and model disagree significantly in the pion kinematics. The measured νµ and νµ interaction rates are consistent, which supports model predictions that the neutrino and antineutrino interaction rates are equal.

  20. Current status of programmes to measure and reduce radon exposure in Irish workplaces

    Energy Technology Data Exchange (ETDEWEB)

    Colgan, P A; Madden, J S; Synnott, H; Fennell, S; Pollard, D; Fenton, D [Radiological Protection Institute of Ireland, 3 Clonskeagh Square, Dublin 14(Ireland)

    2004-06-01

    National legislation, which implements European Council Directive 96/29/EURATOM in Ireland, sets a reference level of 400 Bq m{sup -3} averaged over any 3 month period for radon exposure in the workplace and also empowers the Radiological Protection Institute of Ireland to direct employers to have radon measurements carried out. This legislation came into effect in May 2000. Radon measurements have already been completed in show caves and other underground workplaces. Between 1998 and 2001, over 33 800 individual radon measurements were carried out in all ground floor offices and classrooms in 3444 schools nationwide as part of a programme undertaken jointly with the Department of Education and Science. Where the average indoor radon concentration in one or more rooms exceeded 200 Bq m{sup -3}, remedial measures were implemented. For concentrations up to 400 Bq m{sup -3} this involved increased ventilation while for higher concentrations an active sump was normally installed. The results of the survey, as well as the effectiveness of the different remedial strategies, are discussed. In the case of other above ground workplaces, different approaches have been adopted. As a first step, workplaces in two known high radon areas were directed to have radon measurements carried out. This programme had limited success because of problems in obtaining accurate workplace databases and a general lack of awareness on the part of employers of the issues involved. From a sample of 2610 employers directed to measure radon, only 408 actually completed measurements and 37 workplaces were identified as having average 3 month average radon concentrations above 400 Bq m{sup -3}. A total of 1356 employers ignored all correspondence, some of which was sent by registered post and signed for on receipt. Current initiatives are focused on the provision of information and include newspaper advertising as well as publications aimed specifically at both employer and employee representative

  1. Characterization of Platinum Electrodes and In-situ Cell Confluency Measurement Based on Current Changes of Cell-Electrodes

    Directory of Open Access Journals (Sweden)

    Chin Fhong SOON

    2015-04-01

    Full Text Available This study aimed at the development of a biosensor to examine the growth confluency of human derived keratinocytes (HaCaT cell lines in-situ. The biosensor consists of a sputter- coated glass substrate with platinum patterns. Cells were grown on the conductive substrates and the confluency of the cells were monitored in-situ based on the conductivity changes of the substrates. Characterization of the cell proliferation and confluency were interrogated using electrical cell-substrate impedance sensing (ECIS techniques and current change of cells using a pico-ammeter. The investigation was followed by the electrical characterization of the platinum electrode (PE using a two probe I-V measurement system. The surface morphology of platinum electrodes were studied using an atomic force microscopy (AFM and the HaCaT cell morphology was studied using Field-Emission Scanning Electron Microscopy (FE-SEM. The microscopy results showed that the cells coupled and proliferated on the platinum electrodes. For monitoring the conductivity and impedance changes of the cell-electrode in-situ, the cover of a Petri dish was inserted with pogo pins to be in contact with the platinum electrodes. The impedance was sampled using the ECIS technique at a twenty-four hour interval. In our findings, the cell proliferation rate can be measured by observing the changes in capacitance or impedance measured at low ac frequencies ranged from 10 - 1 kHz. In good agreement, the current measured at micro-ampere range by the biosensor decreased as the cell coverage area increased over the time. Thus, the percent of cell confluence was shown inversely proportional to the current changes.

  2. Rationing critical care medicine: recent studies and current trends.

    Science.gov (United States)

    Ward, Nicholas S

    2005-12-01

    This paper reviews the literature on the rationing of critical care resources. Although much has been written about the concept of rationing, there have been few scientific studies as to its prevalence. A recent meta-analysis reviewed all previously published studies on rationing access to intensive care units but little is known about practices within the intensive care unit. Much literature in the past few years has focused on the growing use of critical care resources and projections for the future. Several authors suggest there may be a crisis in financial or personnel resources if some rationing does not take place. Other papers have argued that the methods of rationing critical care previously proposed, such as limiting the care of dying patients or using cost-effectiveness analysis to determine care, may not be effective or viewed as ethical by some. Finally, several recent papers review how critical care is practiced and allocated in India and Asian countries that already practice open rationing in their health care systems. There is currently no published evidence that overt rationing is taking place in critical care medicine. There is growing evidence that in the future, the need for critical care may outstrip financial resources unless some form of rationing takes place. It is also clear from the literature that choosing how to ration critical care will be a difficult task.

  3. A Measurement of Neutrino-Induced Charged-Current Neutral Pion Production

    Energy Technology Data Exchange (ETDEWEB)

    Nelson, Robert H. [Univ. of Colorado, Boulder, CO (United States)

    2010-01-01

    This work presents the first comprehensive measurement of neutrino-induced charged-current neutral pion production (CCπ0) off a nuclear target. The Mini Booster Neutrino Experiment (MiniBooNE) and Booster Neutrino Beam (BNB) are discussed in detail. MiniBooNE is a high-statistics (~ 1, 000, 000 interactions) low-energy (Evϵ 2 0.5 - 2.0 GeV) neutrino experiment located at Fermilab. The method for selecting and reconstructing CCπ0 events is presented. The π0 and μ- are fully reconstructed in the final state allowing for the measurement of, among other things, the neutrino energy. The total observable CCπ0 cross-section is presented as a function of neutrino energy, along with five differential cross-sections in terms of the final state kinematics and Q2. The results are combined to yield a flux-averaged total cross-section of <σ>Φ = (9.2 ± 0.3stat. ± 1.5syst.) × 10-39 cm2/CH2 at energy 965 MeV. These measurements will aid future neutrino experiments with the prediction of their neutrino interaction rates.

  4. Measurement of high-Q2 neutral current cross-sections with longitudinally polarised positrons with the ZEUS detector

    International Nuclear Information System (INIS)

    Stewart, Trevor P.

    2012-07-01

    The cross sections for neutral current (NC) deep inelastic scattering (DIS) in e + p collisions with a longitudinally polarised positron beam are measured at high momentum transfer squared (Q 2 >185 GeV 2 ) at the ZEUS detector at HERA. The HERA accelerator provides e ± p collisions at a centre-of-mass energy of 318 GeV, which allows the weak contribution to the NC process to be studied at high Q 2 . The measurements are based on a data sample with an integrated luminosity of 135.5 pb -1 collected with the ZEUS detector in 2006 and 2007. The single differential NC cross sections dσ/dQ 2 , dσ/dx and dσ/dy and the reduced cross section σ are measured. The structure function xF 3 is determined by combining the e + p NC reduced cross sections with the previously measured e - p measurements. The interference structure function xF 3 γZ is extracted at Q 2 =1500 GeV 2 . The cross-section asymmetry between the positive and negative polarisation of the positron beam is measured and the parity violation effects of the electroweak interaction are observed. The predictions of the Standard Model of particle physics agree well with the measurements. (orig.)

  5. Measurement of high-Q{sup 2} neutral current cross-sections with longitudinally polarised positrons with the ZEUS detector

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Trevor P.

    2012-07-15

    The cross sections for neutral current (NC) deep inelastic scattering (DIS) in e{sup +}p collisions with a longitudinally polarised positron beam are measured at high momentum transfer squared (Q{sup 2}>185 GeV{sup 2}) at the ZEUS detector at HERA. The HERA accelerator provides e{sup {+-}}p collisions at a centre-of-mass energy of 318 GeV, which allows the weak contribution to the NC process to be studied at high Q{sup 2}. The measurements are based on a data sample with an integrated luminosity of 135.5 pb{sup -1} collected with the ZEUS detector in 2006 and 2007. The single differential NC cross sections d{sigma}/dQ{sup 2}, d{sigma}/dx and d{sigma}/dy and the reduced cross section {sigma} are measured. The structure function xF{sub 3} is determined by combining the e{sup +}p NC reduced cross sections with the previously measured e{sup -}p measurements. The interference structure function xF{sub 3}{sup {gamma}Z} is extracted at Q{sup 2}=1500 GeV{sup 2}. The cross-section asymmetry between the positive and negative polarisation of the positron beam is measured and the parity violation effects of the electroweak interaction are observed. The predictions of the Standard Model of particle physics agree well with the measurements. (orig.)

  6. Magnetic levitation by induced eddy currents in non-magnetic conductors and conductivity measurements

    International Nuclear Information System (INIS)

    Iniguez, J; Raposo, V; Flores, A G; Zazo, M; Hernandez-Lopez, A

    2005-01-01

    We report a study on magnetic levitation by induced ac currents in non-magnetic conductors at low frequencies. Our discussion, based on Faraday's induction law, allows us to distinguish the two components of the current responsible for levitation and heating, respectively. The experimental evaluation of the levitation force in a copper ring revealed the accuracy of our analysis, clearly illustrating its asymptotic behaviour versus frequency, and validating it for the qualitative analysis of magnetic levitation and heating in conductors of different shapes such as tubes and discs, composed of collections of conductive loops. The analysis of the results allows precise values of its electrical conductivity to be found. With the help of a simulation technique, this work also reveals the progressive deformation undergone by magnetic induction lines due to magnetic screening when frequency increases

  7. Magnetic levitation by induced eddy currents in non-magnetic conductors and conductivity measurements

    Energy Technology Data Exchange (ETDEWEB)

    Iniguez, J; Raposo, V; Flores, A G; Zazo, M; Hernandez-Lopez, A [Departamento de Fisica Aplicada, Universidad de Salamanca, E-37071, Salamanca (Spain)

    2005-11-01

    We report a study on magnetic levitation by induced ac currents in non-magnetic conductors at low frequencies. Our discussion, based on Faraday's induction law, allows us to distinguish the two components of the current responsible for levitation and heating, respectively. The experimental evaluation of the levitation force in a copper ring revealed the accuracy of our analysis, clearly illustrating its asymptotic behaviour versus frequency, and validating it for the qualitative analysis of magnetic levitation and heating in conductors of different shapes such as tubes and discs, composed of collections of conductive loops. The analysis of the results allows precise values of its electrical conductivity to be found. With the help of a simulation technique, this work also reveals the progressive deformation undergone by magnetic induction lines due to magnetic screening when frequency increases.

  8. Descriptive currents in philosophy of religion for Hebrew Bible studies

    African Journals Online (AJOL)

    2010-09-30

    Sep 30, 2010 ... problematic currents in the English-speaking world and that we find ourselves in the context of developing postmodern, post-analytic and post-empiricist approaches. Even so, analytic philosophy of religion is still the most representative current in the discipline within the English-speaking world.

  9. Study of current instabilities in high resistivity gallium arsenide

    International Nuclear Information System (INIS)

    Barraud, A.

    1968-01-01

    We have shown the existence and made a study of the current oscillations produced in high-resistivity gallium arsenide by a strong electric field. The oscillations are associated with the slow travelling of a region of high electrical field across the whole sample. An experimental study of the properties of these instabilities has made it possible for us to distinguish this phenomenon from the Gunn effect, from acoustic-electric effects and from contact effects. In order to account for this type of instability, a differential trapping mechanism involving repulsive impurities is proposed; this mechanism can reduce the concentration of charge carriers in the conduction band at strong electrical fields and can lead to the production of a high-field domain. By developing this model qualitatively we have been able to account for all the properties of high-resistance gallium arsenide crystals subjected to a strong electrical field: increase of the Hall constant, existence of a voltage threshold for these oscillations, production of domains of high field, low rate of propagation of these domains, and finally the possibility of inverting the direction of the propagation of the domain without destroying the latter. A quantitative development of the model makes it possible to calculate the various characteristic parameters of these instabilities. Comparison with experiment shows that there is a good agreement, the small deviations coming especially from the lack of knowledge concerning transport properties in gallium arsenide subjected to high fields. From a study of this model, it appears that the instability phenomenon can occur over a wide range of repulsive centre concentrations, and also for a large range of resistivities. This is the reason why it appears systematically in gallium arsenide of medium and high resistivity. (authors) [fr

  10. A STUDY ON QUALITY ANALYSIS MEASURING PROCESS

    OpenAIRE

    Liliana LUCA

    2016-01-01

    The paper presents the results of a study concerning the use of the Ishikawa diagram in analyzing the causes that determine errors in the measuring the sizes of the pieces of machine construction field. The studied problem was "errors in the measurement process” and this constitutes the head of the Ishikawa diagram skeleton.All the possible, main and secondary causes that could generate the studied problem were identified. The paper shows the potential causes of the studied proble...

  11. Korean Clinic Based Outcome Measure Studies

    OpenAIRE

    Jongbae Park

    2003-01-01

    Background: Evidence based medicine has become main tools for medical practice. However, conducting a highly ranked in the evidence hierarchy pyramid is not easy or feasible at all times and places. There remains a room for descriptive clinical outcome measure studies with admitting the limit of the intepretation. Aims: Presents three Korean clinic based outcome measure studies with a view to encouraging Korean clinicians to conduct similar studies. Methods: Three studies are presented...

  12. Multiday Transcranial Direct Current Stimulation Causes Clinically Insignificant Changes in Childhood Dystonia: A Pilot Study.

    Science.gov (United States)

    Bhanpuri, Nasir H; Bertucco, Matteo; Young, Scott J; Lee, Annie A; Sanger, Terence D

    2015-10-01

    Abnormal motor cortex activity is common in dystonia. Cathodal transcranial direct current stimulation may alter cortical activity by decreasing excitability while anodal stimulation may increase motor learning. Previous results showed that a single session of cathodal transcranial direct current stimulation can improve symptoms in childhood dystonia. Here we performed a 5-day, sham-controlled, double-blind, crossover study, where we measured tracking and muscle overflow in a myocontrol-based task. We applied cathodal and anodal transcranial direct current stimulation (2 mA, 9 minutes per day). For cathodal transcranial direct current stimulation (7 participants), 3 subjects showed improvements whereas 2 showed worsening in overflow or tracking error. The effect size was small (about 1% of maximum voluntary contraction) and not clinically meaningful. For anodal transcranial direct current stimulation (6 participants), none showed improvement, whereas 5 showed worsening. Thus, multiday cathodal transcranial direct current stimulation reduced symptoms in some children but not to a clinically meaningful extent, whereas anodal transcranial direct current stimulation worsened symptoms. Our results do not support transcranial direct current stimulation as clinically viable for treating childhood dystonia. © The Author(s) 2015.

  13. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Waldmann, Ole; Ludewigt, Bernhard [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2011-11-15

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm{sup 2} have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material.

  14. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source.

    Science.gov (United States)

    Waldmann, Ole; Ludewigt, Bernhard

    2011-11-01

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm(2) have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material. © 2011 American Institute of Physics

  15. Application possibility of the direct current conduction method for nondestructive crack measurement

    International Nuclear Information System (INIS)

    Riedl, R.

    1982-01-01

    An important value to determine the danger of cracks is the determination of crack depths. The crack depth can be determined quite accurate by means of the direct current conduction method, if one holds onto certain rules. Often complicated experimental set-ups are applied. However, portable commercial devices can be obtained that can be used for partial fluxation, that yield good results. By means of two examples: crack conduction samples in which the built-up of a constant-cracking is persued up to a certain depth, as well as the persuasion of an continuing crack in a bearing cylinder, shall be demonstrated that is very well possible to record accurate profiles with commercial devices and to avoid expensive measurement devices. (orig.) [de

  16. Standard practice for examination of welds using the alternating current field measurement technique

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    2007-01-01

    1.1 This practice describes procedures to be followed during alternating current field measurement examination of welds for baseline and service-induced surface breaking discontinuities. 1.2 This practice is intended for use on welds in any metallic material. 1.3 This practice does not establish weld acceptance criteria. 1.4 The values stated in either inch-pound units or SI units are to be regarded separately as standard. The values stated in each system might not be exact equivalents; therefore, each system shall be used independently of the other. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine the applicability of regulatory limitations prior to use.

  17. Parameter Estimation of Inverter and Motor Model at Standstill using Measured Currents Only

    DEFF Research Database (Denmark)

    Rasmussen, Henrik; Knudsen, Morten; Tønnes, M.

    1996-01-01

    Methods for estimation of the parameters in the electrical equivalent diagram for the induction motor, based on special designed experiments, are given. In all experriments two of the three phases are given the same potential, i.e., no net torque is generatedand the motor is at standstill. Input...... and 3) the referred rotor rotor resistance and magnetizing inductance. The method developed in the two last experiments is independent of the inverter nonlinearity. New methods for system identification concerning saturation of the magnetic flux are given and a reference value for the flux level...... to the system is the reference values for the stator voltages given as duty cycles for the Pulse With Modulated power device. The system output is the measured stator currents. Three experiments are describedgiving respectively 1) the stator resistance and inverter parameters, 2) the stator transient inductance...

  18. Transverse emittance measurement of high-current single pulse beams using pepper-pot method

    International Nuclear Information System (INIS)

    Ke Jianlin; Zhou Changgeng; Qiu Rui

    2013-01-01

    A pepper pot-imaging plate system has been developed and used to measure the 4-D transverse emittance of a vacuum arc ion source. Single beam pulses of tens to hundreds milliamperes were extracted from the plasma with 64 kV high voltage. An imaging plate was laid after the pepper pot to visualize the ion beamlets passing though the holes on the pepper pot. An application program was developed to show the phase-space distribution and calculate the ellipse and RMS emittances. The normalized RMS emittances are about 6.41 π·mm·mrad in x-direction and 4.61 π·mm·mrad in y-direction. It is shown that the emittance of the vacuum arc ion source is much larger than that of other types of ion sources, which is mainly attributed to the high current and the convex meniscus of this source. (authors)

  19. Muon track induced current measurements in semi-insulating GaAs

    Energy Technology Data Exchange (ETDEWEB)

    Eshchenko, D.G., E-mail: dimitry.eshchenko@psi.c [Physik-Institut der Universitaet Zuerich, CH-8057 Zuerich (Switzerland); Laboratory for Muon Spin Spectroscopy, Paul Scherrer Institute, CH-5232 Villigen (Switzerland); Storchak, V.G. [Russian Research Centre ' Kurchatov Institute' , Kurchatov Sq. 1, Moscow 123182 (Russian Federation); Cottrell, S.P. [ISIS Facility, Rutherford Appleton Laboratory, Oxfordshire OX11 OQX (United Kingdom)

    2009-04-15

    We report on preliminary muon-track-induced current measurements in semi-insulating (SI-) GaAs. At T=70K, after simultaneous treatment of the sample by muon irradiation and a strong electric field (a square wave with |E|>10kV/cm and the polarity changed every 1/(50) s) for approximately 2 h, the sample is transferred to a metastable-like state which is characterized by increased life-times for non-equilibrium electrons and holes. The sample can be returned to the original state by heating up to 250 K. Our results for SI-GaAs suggest a muon-track-induced electric-field-assisted neutralization process for the deep traps.

  20. Tijeras Arroyo Groundwater Current Conceptual Model and Corrective Measures Evaluation Report - December 2016.

    Energy Technology Data Exchange (ETDEWEB)

    Copland, John R. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States)

    2017-03-01

    This Tijeras Arroyo Groundwater Current Conceptual Model and Corrective Measures Evaluation Report (CCM/CME Report) has been prepared by the U.S. Department of Energy (DOE) and Sandia Corporation (Sandia) to meet requirements under the Sandia National Laboratories-New Mexico (SNL/NM) Compliance Order on Consent (the Consent Order). The Consent Order, entered into by the New Mexico Environment Department (NMED), DOE, and Sandia, became effective on April 29, 2004. The Consent Order identified the Tijeras Arroyo Groundwater (TAG) Area of Concern (AOC) as an area of groundwater contamination requiring further characterization and corrective action. This report presents an updated Conceptual Site Model (CSM) of the TAG AOC that describes the contaminant release sites, the geological and hydrogeological setting, and the distribution and migration of contaminants in the subsurface. The dataset used for this report includes the analytical results from groundwater samples collected through December 2015.

  1. Current redistribution effects on superconducting d.c, and microwave measurements

    International Nuclear Information System (INIS)

    Barra, M; Cassinese, A; Vaglio, R

    2006-01-01

    In the last two decades, non conventional behavior of the d.c. transport properties of superconductors, with the appearance of anomalous peaks at the transition, have been investigated and interpreted in different ways. In several cases it was recognized that the behavior can be due to current redistribution effects related to the non-homogeneous nature of the measured superconducting sample. In this paper we will briefly review and discuss these effects and, referring to simple concentrated constant equivalent circuits, we will show that sample non-homogeneity can produce the observed features. Then, in the same framework, by performing specific simulations on planar resonators, we will show that anomalous peaks in temperature dependence of the resonant frequency and of the extracted surface reactance can occur at the transition temperature of minority, lower Tc, superconducting phases

  2. Measurement of Muon Neutrino Charged Current Single $\\pi^0$ Production on Hydrocarbon using MINERvA

    Energy Technology Data Exchange (ETDEWEB)

    Altinok, Ozgur [Tufts Univ., Medford, MA (United States)

    2017-01-01

    A sample of charged-current single pion production events for the semi- exclusive channel νµ + CH → µ-π0 + nucleon(s) has been obtained using neutrino exposures of the MINERvA detector. Differential cross sections for muon momentum, muon production angle, pion momentum, pion production angle, and four-momentum transfer square Q2 are reported and are compared to a GENIE-based simulation. The cross section versus neutrino energy is also re- ported. The effects of pion final-state interactions on these cross sections are investigated. The effect of baryon resonance suppression at low Q2 is examined and an event re-weight used by two previous experiments is shown to improve the data versus simulation agreement. The differential cross sections for Q2 for Eν < 4.0 GeV and Eν ≥ 4.0 GeV are examined and the shapes of these distributions are compared to those from the experiment’s $\\bar{v}$µ-CC (π0) measurement. The polarization of the pπ0 system is measured and compared to the simulation predictions. The hadronic invariant mass W distribution is examined for evidence of resonance content, and a search is reported for evidence of a two-particle two-hole (2p2h) contribution. All of the differential cross-section measurements of this Thesis are compared with published MINERvA measurements for νµ-CC (π+) and \\bar{v}$µ-CC (π0) processes.

  3. Unpolarized neutral current e{sup {+-}}p cross section measurements at the H1 experiment, HERA

    Energy Technology Data Exchange (ETDEWEB)

    Habib, Shiraz Z.

    2009-11-15

    Measurements of the unpolarized inclusive neutral current reduced cross section in e{sup {+-}}p scattering at a center of mass energy {radical}(s) {approx_equal} 319 GeV are presented. The data was collected by the H1 detector during the HERA II running phase, after the 2000 luminosity upgrade, and corresponds to an integrated luminosity of 145 pb{sup -1} and 167 pb{sup -1} for the e{sup -}p and e{sup +}p periods respectively. The cross section measurements were made for the negative four-momentum transfer squared range 65{<=} Q{sup 2}{<=}30000 GeV{sup 2} and Bjorken-x range 0.00085{<=}x{<=}0.65. Dedicated measurements at inelasticity y=0.75 and Q{sup 2}{<=}800 GeV{sup 2} are also made. The details of the analysis are presented here. The cross section measurements presented here are found to agree with previously published data as well as predictions determined from various NLO QCD fits. Scaling violation of the F{sub 2} structure function as well differences between the e{sup -} and e{sup +} cross sections at high Q{sup 2} due to the xF{sub 3} structure function have been observed. The cross sections in the range Q{sup 2}{<=}800 GeV{sup 2} at inelasticity y=0.75 suggest non-zero values of the longitudinal structure function F{sub L}. (orig.)

  4. Detection and evaluation of weld defects in stainless steel using alternating current field measurement

    Science.gov (United States)

    Wei-Li, Ma, Weiping; Pan-Qi, Wen-jiao, Dou; Yuan, Xin'an; Yin, Xiaokang

    2018-04-01

    Stainless steel is widely used in nuclear power plants, such as various high-radioactive pool, tools storage and fuel transportation channel, and serves as an important barrier to stop the leakage of high-radioactive material. NonDestructive Evaluation (NDE) methods, eddy current testing (ET), ultrasonic examination (UT), penetration testing (PT) and hybrid detection method, etc., have been introduced into the inspection of a nuclear plant. In this paper, the Alternating Current Field Measurement (ACFM) was fully applied to detect and evaluate the defects in the welds of the stainless steel. Simulations were carried out on different defect types, crack lengths, and orientation to reveal the relationship between the signals and dimensions to determine whether methods could be validated by the experiment. A 3-axis ACFM probe was developed and three plates including 16 defects, which served in nuclear plant before, were examined by automatic detection equipment. The result shows that the minimum detectable crack length on the surface is 2mm and ACFM shows excellent inspection results for a weld in stainless steel and gives an encouraging prospect of broader application.

  5. A general centroid determination methodology, with application to multilayer dielectric structures and thermally stimulated current measurements

    International Nuclear Information System (INIS)

    Miller, S.L.; Fleetwood, D.M.; McWhorter, P.J.; Reber, R.A. Jr.; Murray, J.R.

    1993-01-01

    A general methodology is developed to experimentally characterize the spatial distribution of occupied traps in dielectric films on a semiconductor. The effects of parasitics such as leakage, charge transport through more than one interface, and interface trap charge are quantitatively addressed. Charge transport with contributions from multiple charge species is rigorously treated. The methodology is independent of the charge transport mechanism(s), and is directly applicable to multilayer dielectric structures. The centroid capacitance, rather than the centroid itself, is introduced as the fundamental quantity that permits the generic analysis of multilayer structures. In particular, the form of many equations describing stacked dielectric structures becomes independent of the number of layers comprising the stack if they are expressed in terms of the centroid capacitance and/or the flatband voltage. The experimental methodology is illustrated with an application using thermally stimulated current (TSC) measurements. The centroid of changes (via thermal emission) in the amount of trapped charge was determined for two different samples of a triple-layer dielectric structure. A direct consequence of the TSC analyses is the rigorous proof that changes in interface trap charge can contribute, though typically not significantly, to thermally stimulated current

  6. Ka-band Doppler Scatterometer for Measurements of Ocean Vector Winds and Surface Currents

    Data.gov (United States)

    National Aeronautics and Space Administration — Ocean surface currents impact heat transport, surface momentum and gas fluxes, ocean productivity and marine biological communities. Ocean currents also have social...

  7. Study of efficiency and current use of respiratory protective devices

    International Nuclear Information System (INIS)

    Linauskas, S.H.; Kalos, F.

    1984-12-01

    The efficiency of a helmet-type powered air-purifying respirator was studied in the work environment of an underground uranium mine. Workplace protection factors (WPF) were measured, using approximately 30-minute air sampling periods and repeated sampling throughout the work shifts for six miners during three shifts each. The WPF of the modified Racal AH-5 helmet was 17.8 (geometric mean) with new filters in the respirator; the WPF dropped to 5.3 when four-day-old filters were used. The WPF results were lognormally distributed. The test population appeared to be a homogeneous set: there was no significant difference in the mean WPFs of individual test subjects. The study could not resolve any effect of elapsed time within the work shift or of ambient Working Level on the WPF. The actual use levels and the problems associated with respirator use were studied at the same time, principally via a user survey. The respirators have a high level of acceptance among the user population of underground uranium miners and 72.5 percent of the 207 survey respondents stated six or more hours use with the visor in the correct 'down' position per shift

  8. Study of plasma equilibrium during the AC current reversal phase in STOR-M

    International Nuclear Information System (INIS)

    Xiao, C.

    2002-01-01

    Alternating current (AC) tokamak operation and equilibrium studies have been performed on the STOR-M tokamak. The recent experiments have achieved consistent smooth current reversal through the implementation of a hybrid digital-analog position controller and by careful density control. In order to study the plasma equilibrium during the current reversal phase with negligible rotational transform, a segmented limiter with four isolated conducting plates has been installed. The plates can be connected outside the vacuum vessel, which allows measurements of currents flowing between limiter plates. When the current reversal is smooth with zero dwell time, the hydrogen line emission level and electron density remain finite, indicating a finite particle confinement. The current from the top to the bottom limiter plate is also finite and its direction is consistent with that of the grad-B drift. The observation suggests that the limiter and other conducting structures surrounding the plasmas plays the role, during the current reversal phase of AC tokamak operation, to short out the charge separation arising from the grad-B drift and to maintain a finite particle confinement. (author)

  9. Study of non inductive current generation in a plasma

    International Nuclear Information System (INIS)

    Rax, J.M.

    1987-01-01

    The problem of non-thermal bremsstrahlung during lower hybrid current drive is considered. The proposed method shows the role of the Compton effects at low frequencies and allows us to establish the link between the emitted power and the absorbed power at high frequency. The non-thermal emission is considered as a kinematical mode conversion between the absorbed radio-frequency mode and the emitted X ray photons. The fast electrons diagnostics and the ways to reach the wave structure are shown. Kinetic and electromagnetic problems concerning current generation are described. The plasma properties and diagnostics in the case of a non inductive current generation are discussed [fr

  10. Using a 1200 kHz workhorse ADCP with mode 12 to measure near bottom mean currents

    Science.gov (United States)

    Martini, M.; ,

    2003-01-01

    Using high frequency Acoustic Doppler Current (ADCP) profiling technology, it is possible to make high-resolution measurements of mean current profiles within a few meters of the seabed. In coastal applications, mean current speeds may be 10 cm/s or less, and oscillatory wave currents may exceed 100 cm/s during storm events. To resolve mean flows of 10 cm/s or less under these conditions, accuracies of 1 cm/s or better are desirable.

  11. Theoretical study of a flat eddy current probe

    International Nuclear Information System (INIS)

    Bouchard, A.; Dumont-Fillon, J.; Labbe, G.

    1976-01-01

    A mathematical model for the computation of the impedance of an eddy current probe has been determined in the case of flat product testing. Various applications are discussed with particular emphasis on ferromagnetic materials [fr

  12. Measurement of fragmentation properties of charmed particle production in charged-current neutrino interactions

    CERN Document Server

    Onengüt, G; De Jong, M; Konijn, J; Melzer, O; Oldeman, R G C; Pesen, E; Van der Poel, C A F J; Visschers, J L; Güler, M; Köse, U; Serin-Zeyrek, M; Kama, S; Sever, R; Tolun,, P; Zeyrek, M T; Catanesi, M G; De Serio, M; Ieva, M; Muciaccia, M T; Radicioni, E; Simone, S; Bülte, A; Winter, Klaus; Van de Vyver, B; Vilain, P; Wilquet, G; Saitta, B; Di Capua, E; Ogawa, S; Shibuya, H; Artamonov, A V; Brunner, J; Chizhov, M; Cussans, D G; Doucet, M; Fabre, Jean-Paul; Hristova, I R; Kawamura, T; Kolev, D; Litmaath, M; Meinhard, H; Panman, J; Papadopoulos, I M; Ricciardi, S; Rozanov, A; Saltzberg, D; Tsenov, R V; Uiterwijk, J W E; Zucchelli, P; Goldberg, J; Chikawa, M; Arik, E; Song, J S; Yoon, C S; Kodama, K; Ushida, N; Aoki, S; Hara, T; Delbar, T; Favart, D; Grégoire, G; Kalinin, S; Makhlyoueva, I V; Gorbunov, P; Khovanskii, V D; Shamanov, V V; Tsukerman, I; Bruski, N; Frekers, D; Rondeshagen, D; Wolff, T; Hoshino, K; Kawada, J; Komatsu, M; Miyanishi, M; Nakamura, M; Nakano, T; Narita, K; Niu, K; Niwa, K; Nonaka, N; Sato, O; Toshito, T; Buontempo, S; Cocco, A G; D'Ambrosio, N; De Lellis, G; De Rosa, G; Di Capua, F; Ereditato, A; Fiorillo, G; Marotta, A; Messina, M; Migliozzi, P; Pistillo, C; Santorelli, R; Scotto-Lavina, L; Strolin, P; Tioukov, V; Nakamura, K; Okusawa, T; Dore, U; FLoverre, P; Ludovici, L; Maslennikov, A L; Righini, P; Rosa, G; Santacesaria, R; Satta, A; Spada, F R; Barbuto, E; Bozza, C; Grella, G; Romano, G; Sirignano, C; Sorrentino, S; Sato, Y; Tezuka, I

    2004-01-01

    During the years 1994-97, the emulsion target of the CHORUS detector was exposed to the wideband neutrino beam of the CERN SPS. In total about 100 000 charged-current neutrino interactions were located in the nuclear emulsion target and fully reconstructed. From this sample of events which was based on the data acquired by new automatic scanning systems, 1048 D0 events were selected by a pattern recognition program. They were confirmed as neutral-particle decays through visual inspection. Fragmentation properties of deep-inelastic charm production were measured using these events. Distributions of the D0 momentum, Feynman x(x_F), z and tan thetaôut, the transverse angle out of the leptonic plane defined by the muon and the neutrino, are presented. The mean value of z was measured to be (z) = 0.63 +- 0.03(stat) +- 0.01(syst). From fits to the z distribution, values for the Peterson parameter epsilon_p = 0.108 +- 0.017(stat) +- 0.013(syst) and the Collins-Spiller parameter epsilon_CS = 0.21^+0.05_-0.04(stat) +...

  13. Scale Thickness Measurement of Steam Generator Tubing Using Eddy Current Signal of Bobbin Coil

    International Nuclear Information System (INIS)

    Kim, Chang Soo; Um, Ki Soo; Kim, Jae Dong

    2012-01-01

    Steam generator is one of the major components of nuclear power plant and steam generator tubes are the pressure boundary between primary and secondary side, which makes them critical for nuclear safety. As the operating time of nuclear power plant increases, not only damage mechanisms but also scaled deposits on steam generator tubes are known to be problematic causing tube support flow hole blockage and heat fouling. The ability to assess the extent and location of scaled deposits on tubes became essential for management and maintenance of steam generator and eddy current bobbin data can be utilized to measure thickness of scale on tubes. In this paper, tube reference standards with various thickness of scaled deposit has been set up to provide information about the overall deposit condition of steam generator tubes, providing essential tool for steam generator management and maintenance to predict and prevent future damages. Also, methodology to automatically measure scale thickness on tubes has been developed and applied to field data to estimate overall scale amount.

  14. Establishment of a semi-biological phantom model for the study of the effect of dose reducing measures on radiation-induced DNA double strand breaks in CT using the example of risk organ based tube current modulation; Etablierung eines semibiologischen Phantommodells zur Untersuchung des Effekts dosisreduzierender Massnahmen auf strahleninduzierte DNA-Doppelstrangbrueche in der CT am Beispiel der risikoorganbasierten Roehrenstrommodulation

    Energy Technology Data Exchange (ETDEWEB)

    Sommer, Matthias

    2013-12-12

    The number of computed tomography (CT) examinations has been rising during the last decades. Therefore techniques for dose reduction receive increasing attention. Risk organ-based tube current modulation (RCM) in CT is a new approach and works by lowering the tube current, while the tube is in front of the patient's body. Therefore it should lead to a dose reduction for radiosensitive organs like the female breast, the eye lenses and the thyroid gland. Biological radiation effects cannot be estimated by physical-based dose measurements. γ-H2AX is a sensitive marker for the determination of x-ray induced DNA double-strand breaks (DSB). Hence the aim of this study was to establish a biological phantom model based on the γ-H2AX immunofluorescence microscopy method and to investigate the effect of RCM on radiation induced DNA damages. The γ-H2AX method is based on the phosphorylation of the histone variant H2AX. The phosphorylated histone γ-H2AX can be visualised using antibodies and is specific for radiation induced DSB. Blood lymphocytes from healthy volunteers, skin fibroblasts (LN) and mammary epithelial cells (HMEpC-p) were placed in different positions of an Alderson-phantom and exposed to x-rays using a 128-slice dual-source CT scanner. Standard head, neck and chest-CT scan protocols either with or without risk-organ based tube current modulation were used. RCM reduces the tube current to 20 percent at an angle of 130 degree anterior to the body, whereas tube current is increased at an angle of 230 degree posterior to the body. Afterwards cells were isolated, fixed on slides und stained with specific primary γ-H2AX antibodies and fluorescent secondary antibodies. Tiny green dots (named foci) can be detected and quantified with a fluorescence microscope and represent distinct DSB. Non-irradiated samples served as controls and CT-induced DSB were calculated by subtraction of pre- from post-exposure values. In this study a semibiological phantom model

  15. Measurement of Neutral-Current Four-Fermion Production at LEP2

    CERN Document Server

    Abbiendi, G.; Akesson, P.F.; Alexander, G.; Allison, John; Amaral, P.; Anagnostou, G.; Anderson, K.J.; Arcelli, S.; Asai, S.; Axen, D.; Azuelos, G.; Bailey, I.; Barberio, E.; Barlow, R.J.; Batley, R.J.; Bechtle, P.; Behnke, T.; Bell, Kenneth Watson; Bell, P.J.; Bella, G.; Bellerive, A.; Benelli, G.; Bethke, S.; Biebel, O.; Bloodworth, I.J.; Boeriu, O.; Bock, P.; Bonacorsi, D.; Boutemeur, M.; Braibant, S.; Brigliadori, L.; Brown, Robert M.; Buesser, K.; Burckhart, H.J.; Campana, S.; Carnegie, R.K.; Caron, B.; Carter, A.A.; Carter, J.R.; Chang, C.Y.; Charlton, David G.; Csilling, A.; Cuffiani, M.; Dado, S.; Dallavalle, G.Marco; Dallison, S.; De Roeck, A.; De Wolf, E.A.; Desch, K.; Dienes, B.; Donkers, M.; Dubbert, J.; Duchovni, E.; Duckeck, G.; Duerdoth, I.P.; Elfgren, E.; Etzion, E.; Fabbri, F.; Feld, L.; Ferrari, P.; Fiedler, F.; Fleck, I.; Ford, M.; Frey, A.; Furtjes, A.; Gagnon, P.; Gary, John William; Gaycken, G.; Geich-Gimbel, C.; Giacomelli, G.; Giacomelli, P.; Giunta, Marina; Goldberg, J.; Gross, E.; Grunhaus, J.; Gruwe, M.; Gunther, P.O.; Gupta, A.; Hajdu, C.; Hamann, M.; Hanson, G.G.; Harder, K.; Harel, A.; Harin-Dirac, M.; Hauschild, M.; Hauschildt, J.; Hawkes, C.M.; Hawkings, R.; Hemingway, R.J.; Hensel, C.; Herten, G.; Heuer, R.D.; Hill, J.C.; Hoffman, Kara Dion; Homer, R.J.; Horvath, D.; Howard, R.; Huntemeyer, P.; Igo-Kemenes, P.; Ishii, K.; Jeremie, H.; Jovanovic, P.; Junk, T.R.; Kanaya, N.; Kanzaki, J.; Karapetian, G.; Karlen, D.; Kartvelishvili, V.; Kawagoe, K.; Kawamoto, T.; Keeler, R.K.; Kellogg, R.G.; Kennedy, B.W.; Kim, D.H.; Klein, K.; Klier, A.; Kluth, S.; Kobayashi, T.; Kobel, M.; Komamiya, S.; Kormos, Laura L.; Kowalewski, Robert V.; Kramer, T.; Kress, T.; Krieger, P.; von Krogh, J.; Krop, D.; Kruger, K.; Kupper, M.; Lafferty, G.D.; Landsman, H.; Lanske, D.; Layter, J.G.; Leins, A.; Lellouch, D.; Letts, J.; Levinson, L.; Lillich, J.; Lloyd, S.L.; Loebinger, F.K.; Lu, J.; Ludwig, J.; Macpherson, A.; Mader, W.; Marcellini, S.; Marchant, T.E.; Martin, A.J.; Martin, J.P.; Masetti, G.; Mashimo, T.; Mattig, Peter; McDonald, W.J.; McKenna, J.; McMahon, T.J.; McPherson, R.A.; Meijers, F.; Mendez-Lorenzo, P.; Menges, W.; Merritt, F.S.; Mes, H.; Michelini, A.; Mihara, S.; Mikenberg, G.; Miller, D.J.; Moed, S.; Mohr, W.; Mori, T.; Mutter, A.; Nagai, K.; Nakamura, I.; Neal, H.A.; Nisius, R.; O'Neale, S.W.; Oh, A.; Okpara, A.; Oreglia, M.J.; Orito, S.; Pahl, C.; Pasztor, G.; Pater, J.R.; Patrick, G.N.; Pilcher, J.E.; Pinfold, J.; Plane, David E.; Poli, B.; Polok, J.; Pooth, O.; Przybycien, M.; Quadt, A.; Rabbertz, K.; Rembser, C.; Renkel, P.; Rick, H.; Roney, J.M.; Rosati, S.; Rozen, Y.; Runge, K.; Sachs, K.; Saeki, T.; Sahr, O.; Sarkisyan, E.K.G.; Schaile, A.D.; Schaile, O.; Scharff-Hansen, P.; Schieck, J.; Schoerner-Sadenius, Thomas; Schroder, Matthias; Schumacher, M.; Schwick, C.; Scott, W.G.; Seuster, R.; Shears, T.G.; Shen, B.C.; Shepherd-Themistocleous, C.H.; Sherwood, P.; Siroli, G.; Skuja, A.; Smith, A.M.; Sobie, R.; Soldner-Rembold, S.; Spagnolo, S.; Spano, F.; Stahl, A.; Stephens, K.; Strom, David M.; Strohmer, R.; Tarem, S.; Tasevsky, M.; Taylor, R.J.; Teuscher, R.; Thomson, M.A.; Torrence, E.; Toya, D.; Tran, P.; Trefzger, T.; Tricoli, A.; Trigger, I.; Trocsanyi, Z.; Tsur, E.; Turner-Watson, M.F.; Ueda, I.; Ujvari, B.; Vachon, B.; Vollmer, C.F.; Vannerem, P.; Verzocchi, M.; Voss, H.; Vossebeld, J.; Waller, D.; Ward, C.P.; Ward, D.R.; Watkins, P.M.; Watson, A.T.; Watson, N.K.; Wells, P.S.; Wengler, T.; Wermes, N.; Wetterling, D.; Wilson, G.W.; Wilson, J.A.; Wolf, G.; Wyatt, T.R.; Yamashita, S.; Zer-Zion, D.; Zivkovic, Lidija

    2002-01-01

    Four-fermion final states qqbar e+e- and qqbar mu+mu- from neutral-current interactions in e+e- collisions are studied in the OPAL detector at LEP at centre-of-mass energies from 183 GeV to 209 GeV. The data analysed correspond to a total integrated luminosity of about 650 pb-1 recorded from 1997 to 2000. Corresponding to the acceptance of the OPAL detector, a signal definition is applied requiring both leptons to have a scattering angle satisfying cos0 qqbar e+e- and e+e- qqbar mu+mu- are consistent with the expectations from the Standard Model.

  16. Thermographic Phosphors for High Temperature Measurements: Principles, Current State of the Art and Recent Applications

    Directory of Open Access Journals (Sweden)

    Konstantinos Kontis

    2008-09-01

    Full Text Available This paper reviews the state of phosphor thermometry, focusing on developments in the past 15 years. The fundamental principles and theory are presented, and the various spectral and temporal modes, including the lifetime decay, rise time and intensity ratio, are discussed. The entire phosphor measurement system, including relative advantages to conventional methods, choice of phosphors, bonding techniques, excitation sources and emission detection, is reviewed. Special attention is given to issues that may arise at high temperatures. A number of recent developments and applications are surveyed, with examples including: measurements in engines, hypersonic wind tunnel experiments, pyrolysis studies and droplet/spray/gas temperature determination. They show the technique is flexible and successful in measuring temperatures where conventional methods may prove to be unsuitable.

  17. The nitrogen fate beyond the current nutrient mitigation measures: sustainability of an integrated agriculture

    Science.gov (United States)

    Thieu, V.; Billen, G. F.; Garnier, J.; Lancelot, C.; Gypens, N.

    2010-12-01

    Located in the North-Western Europe the terrestrial continuum that includes the Seine, Somme, and Scheldt River basins offers an interesting example of a transborder territory (France, Belgium, and Netherlands) with high-intensity anthropogenic pressures. It well-illustrates the rapid development of modern agriculture in industrialised countries and the resulting severe alteration of water resources and jeopardising the capacity of rural territories to produce drinking water. The corresponding nutrient loads delivered then into the Southern Bight of the North Sea, strongly affect the ecological functioning of the coastal zone. An integrated ‘river-ocean’ assessment, coupling two deterministic models - the SENEQUE RIVESTRAHLER model simulating nutrient dynamic in the drainage network and the MIRO model describing the ecological functioning coastal ecosystem - points out the relevance of current policy based measures (improvement of waste water treatment) to mitigate phosphorous emissions, while the nitrogen pollution related to agriculture will remain critical despite the implementation of classical management measure (good agricultural practices). Therefore and irrespectively of the current political agenda, a more radical alternative is established, consisting of a generalised shift to an integrated agriculture of all agricultural areas in the three basins, excluding the use of synthetically compounded fertilisers and the importation of livestock feed. Such scenario aims at evaluating whether agriculture, by essence, can conciliate (i) the demand for food and feed by local populations, (ii) a good ecological functioning of aquatic ecosystems and (iii) a balanced nutrient status for the adjacent coastal area. This scenario involves an increased livestock density in the Seine and Somme and a decrease in livestock in the Scheldt basin. It leads to a significant reduction of agricultural production that finally brings the three basins closer to autotrophy

  18. Study of lower hybrid current drive for the demonstration reactor

    Energy Technology Data Exchange (ETDEWEB)

    Molavi-Choobini, Ali Asghar [Dept. of Physics, Faculty of Engineering, Islamic Azad University, Shahr-e-kord Branch, Shahr-e-kord (Iran, Islamic Republic of); Naghidokht, Ahmed [Dept. of Physics, Urmia University, Urmia (Iran, Islamic Republic of); Karami, Zahra [Dept. of Engineering, Islamic Azad University, Zanjan Branch, Zanjan (Iran, Islamic Republic of)

    2016-06-15

    Steady-state operation of a fusion power plant requires external current drive to minimize the power requirements, and a high fraction of bootstrap current is required. One of the external sources for current drive is lower hybrid current drive, which has been widely applied in many tokamaks. Here, using lower hybrid simulation code, we calculate electron distribution function, electron currents and phase velocity changes for two options of demonstration reactor at the launched lower hybrid wave frequency 5 GHz. Two plasma scenarios pertaining to two different demonstration reactor options, known as pulsed (Option 1) and steady-state (Option 2) models, have been analyzed. We perceive that electron currents have major peaks near the edge of plasma for both options but with higher efficiency for Option 1, although we have access to wider, more peripheral regions for Option 2. Regarding the electron distribution function, major perturbations are at positive velocities for both options for flux surface 16 and at negative velocities for both options for flux surface 64.

  19. General and Specific Approaches to Media Parenting: A Systematic Review of Current Measures, Associations with Screen-Viewing, and Measurement Implications

    Science.gov (United States)

    Edwards, Mark J.; Urbanski, Carly R.; Sebire, Simon J.

    2013-01-01

    Abstract Background Parent-focused interventions may help to reduce youth screen-viewing (SV). This review synthesized current information on the links between parenting styles, parenting practices, and youth SV with a focus on measurement. Methods A systematic review of electronic databases was conducted. Results In all, 29 of 1189 studies met the inclusion criteria. Parenting practices were divided into rule and nonrule-based practices. Seven rules: (1) Limits on total time (n studies=23); (2) limits on time of day (n=7); (3) content restriction (n=11); (4) mealtime rules (n=2); (5) parental supervision (n=3); (6) contingent screentime (n=3); and (7) no-TV policy (n=1) were reported. Two nonrule-based practices were reported: Co-viewing (n=6) and encouragement to view (n=2). Three studies (10.3%) provided information on parenting styles. Only 12 studies (41.4%) provided information on the reliability/validity of the outcome measure, 15 (51.7%) studies provided information on the reliability/validity of the parenting measure, and 6 (20.7%) provided information on the reliability/validity of both outcome and exposure measures. Conclusions There is mixed evidence that parenting styles and media-related parenting practices are associated with youth SV. The assessment of parental influence of youth media use is hampered by the diversity of measures that have been used. There is a need for new measures that assess a range of media parenting practices that are relevant to multiple forms of SV. PMID:23944925

  20. Trend of environmental radiation protection and its current related studies

    International Nuclear Information System (INIS)

    Yoshida, Satoshi

    2011-01-01

    Reviewed are the international trend of environmental radiation protection (ERP), Japanese studies of radiation effects on environmental livings from aspects of ecosystem to molecular level, and the future view. ERP is particularly closed up toward promotion after its first involvement in the general global conference, UN Conference on Environment and Development (1992). International Commission of Radiological Protection (ICRP) has conducted such actions for the environment as establishing protection essentials for non-human species (2003), organizing Committee 5 (2005), and defining Reference Animals and Plants (2008) where Derived Consideration Reference Levels of 0.1-100 mGy/d are proposed, together with cooperative actions by United Nations Scientific Committee on the Effects of Atomic Radiation (UNSCEAR), International Atomic Energy Agency (IAEA), The Organization for Economic Co-operation and Development (OECD)/Nuclear Energy Agency (NEA) and European projects. Japanese NIRS is now enrolled in the project of Environmental Modeling for Radiation Safety-II (IAEA). Major Japanese studies of radiation effects on environmental livings have utilized killifish (medaka: Oryzias latipes), springtail, earthworm, nematode, cultured plant cell (cedar), poplar, etc. Studies of the radiation effect on microcosm consisting of 3 livings have led to establishing a model for mathematical analysis and of 8 livings, have defined 50% affect dose of 5600 Gy gamma-ray. Irradiation of gamma-ray at 1 Gy/d for 5-10 days to the soil has been shown to result in alteration of the composition of natural earth bacterial population by denaturant gradient gel electrophoresis, which being a promising tool for evaluating the alteration of soil composition and function. At molecular levels, transcriptome analysis of various cells from yeast to man, is performed after irradiation of gamma-ray, neutron, heavy particles and others to reveal radiation-induced gene expression; and Hi-CEP (high