WorldWideScience

Sample records for current site operations

  1. List of currently classified documents relative to Hanford Production Facilities Operations originated on the Hanford Site between 1961 and 1972

    Energy Technology Data Exchange (ETDEWEB)

    1993-04-01

    The United States Department of Energy (DOE) has declared that all Hanford plutonium production- and operations-related information generated between 1944 and 1972 is declassified. Any documents found and deemed useful for meeting Hanford Environmental Dose Reconstruction (HEDR) objectives may be declassified with or without deletions in accordance with DOE guidance by Authorized Derivative Declassifiers. The September 1992, letter report, Declassifications Requested by the Technical Steering Panel of Hanford Documents Produced 1944--1960, (PNWD-2024 HEDR UC-707), provides an important milestone toward achieving a complete listing of documents that may be useful to the HEDR Project. The attached listing of approximately 7,000 currently classified Hanford-originated documents relative to Hanford Production Facilities Operations between 1961 and 1972 fulfills TSP Directive 89-3. This list does not include such titles as the Irradiation Processing Department, Chemical Processing Department, and Hanford Laboratory Operations monthly reports generated after 1960 which have been previously declassified with minor deletions and made publicly available. Also Kaiser Engineers Hanford (KEH) Document Control determined that no KEH documents generated between January 1, 1961 and December 31, 1972 are currently classified. Titles which address work for others have not been included because Hanford Site contractors currently having custodial responsibility for these documents do not have the authority to determine whether other than their own staff have on file an appropriate need-to-know. Furthermore, these documents do not normally contain information relative to Hanford Site operations.

  2. Drug Establishments Current Registration Site

    Data.gov (United States)

    U.S. Department of Health & Human Services — The Drug Establishments Current Registration Site (DECRS) is a database of current information submitted by drug firms to register establishments (facilities) which...

  3. Electric Vehicle Site Operator Program

    Energy Technology Data Exchange (ETDEWEB)

    1992-01-01

    Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy's Electric Vehicle Site Operator Program. Through participation is this program, Kansas State is demonstrating, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one (1) electric or hybrid van and four (4) electric cars during the first two years of this five year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two (2) Soleq 1992 Ford EVcort stationwagons.

  4. Hanford Site air operating permit application

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The Clean Air Act Amendments of 1990, which amended the Federal Clean Air Act of 1977, required that the US Environmental Protection Agency develop a national Air Operating Permit Program, which in turn would require each state to develop an Air Operating Permit Program to identify all sources of ``regulated`` pollutants. Regulated pollutants include ``criteria`` pollutants (oxides of nitrogen, sulfur oxides, total suspended particulates, carbon monoxide, particulate matter greater than 10 micron, lead) plus 189 other ``Hazardous`` Air Pollutants. The Hanford Site, owned by the US Government and operated by the US Department of Energy, Richland Operations Office, is located in southcentral Washington State and covers 560 square miles of semi-arid shrub and grasslands located just north of the confluence of the Snake and Yakima Rivers with the Columbia River. This land, with restricted public access, provides a buffer for the smaller areas historically used for the production of nuclear materials, waste storage, and waste disposal. About 6 percent of the land area has been disturbed and is actively used. The Hanford Site Air Operating Permit Application consists of more than 1,100 sources and in excess of 300 emission points. Before January 1995, the maintenance and operations contractor and the environmental restoration contractor for the US Department of Energy completed an air emission inventory on the Hanford Site. The inventory has been entered into a database so that the sources and emission points can be tracked and updated information readily can be retrieved. The Hanford Site Air Operating Permit Application contains information current as of April 19, 1995.

  5. Influence of Current Transformer Saturation on Operation of Current Protection

    Directory of Open Access Journals (Sweden)

    F. A. Romaniouk

    2010-01-01

    Full Text Available An analysis of the influence of instrument current transformer errors on operation of current protection of power supply diagram elements has been carried out in the paper. The paper shows the influence of an aperiodic component of transient current and secondary load on current  transformer errors.Peculiar operational features of measuring elements of electromechanical and microprocessor current protection with their joint operation with electromagnetic current transformers have been analyzed in the paper.

  6. Waste Sites - Municipal Waste Operations

    Data.gov (United States)

    NSGIC Education | GIS Inventory — A Municipal Waste Operation is a DEP primary facility type related to the Waste Management Municipal Waste Program. The sub-facility types related to Municipal Waste...

  7. Operations Management on The Construction Site

    DEFF Research Database (Denmark)

    Koch, Christian

    2004-01-01

    this as a refreshing renewal and improvement of practical operations management at the site. However this paper will present a first step of development of a new approach to operations management at the building site, which at the same time builds on, and criticize lean construction for missing the point...... of the knowledge economy. This endeavour is carried out in two ways. First by a reading of the operations management literature. Juxtaposing this with lean construction extentions and the critique developed by other scholars. And also drawing on human resource management approaches. Second through a series......” scheme. In both directions it is revealed that the human resource and knowledge element of building processes is largely left untouched by lean construction methods. It is suggested to introduce at least two more dimensions of operations management at the site than the ones offered in lean construction...

  8. Operations Management on The Construction Site

    DEFF Research Database (Denmark)

    Koch, Christian

    2004-01-01

    ; human resource issues (knowledge) and site management issues. The seven “healthy stream-s” focus on whether the human resources are available, but no not understand the competence and knowledge content. Moreover the empirical research revealed that site management themselves creating “stumbling stones......In these years lean construction approaches is flourishing in Danish building projects. The Koskela (2000) concepts such as the TFV-perspectives (Transformation, Flow, Value) and the last planner (Ballard 2000) are directly used in attempts to rationalize building processes. One can receive...... this as a refreshing renewal and improvement of practical operations management at the site. However this paper will present a first step of development of a new approach to operations management at the building site, which at the same time builds on, and criticize lean construction for missing the point...

  9. Current and Future Flight Operating Systems

    Science.gov (United States)

    Cudmore, Alan

    2007-01-01

    This viewgraph presentation reviews the current real time operating system (RTOS) type in use with current flight systems. A new RTOS model is described, i.e. the process model. Included is a review of the challenges of migrating from the classic RTOS to the Process Model type.

  10. A CMOS current-mode operational amplifier

    DEFF Research Database (Denmark)

    Kaulberg, Thomas

    1993-01-01

    A fully differential-input, differential-output, current-mode operational amplifier (COA) is described. The amplifier utilizes three second-generation current conveyors (CCIIs) as the basic building blocks. It can be configured to provide either a constant gain-bandwidth product in a fully balanced...... current-mode feedback amplifier or a constant bandwidth in a transimpedance feedback amplifier. The amplifier is found to have a gain-bandwidth product of 3 MHz, an offset current of 0.8 μA (signal range ±700 μA), and a (theoretically) unlimited slew rate. The amplifier is realized in a standard CMOS 2...

  11. CMOS Current-mode Operational Amplifier

    DEFF Research Database (Denmark)

    Kaulberg, Thomas

    1992-01-01

    A fully differential-input differential-output current-mode operational amplifier (COA) is described. The amplifier utilizes three second generation current-conveyors (CCII) as the basic building blocks. It can be configured to provide either a constant gain-bandwidth product in a fully balanced...... current-mode feedback amplifier or a constant bandwidth in a transimpedance feedback amplifier. The amplifier is found to have a gain bandwidth product of 8 MHz, an offset current of 0.8 ¿A (signal-range ±700¿A) and a (theoretically) unlimited slew-rate. The amplifier is realized in a standard CMOS 2...

  12. [Current possibilities to influence surgical site infection].

    Science.gov (United States)

    Bělina, F

    2017-01-01

    Infections associated with surgical procedures, also referred to as surgical site infections (SSIs), are the most common nosocomial infections (HAIs - Health Care-Associated Infections) in surgery departments. Although effectively preventable in most cases, they are still associated with significant morbidity and mortality, prolonged or repeated hospitalizations and increased treatment costs. Therefore, compliance with applicable procedures and guidelines is essential for SSI prevention, which was also shown in numerous EBM studies. Relevant procedures and clinical guidelines involve all phases of perioperative care, covering preoperative patient preparation, the course of the surgical procedure itself, as well as post-operative care. In order to effectively reduce the risk of postoperative infectious complications, these proven principles and procedures need to be implemented into daily practice with every single surgical patient. Continuous monitoring of compliance with these procedures, staff education, recording the incidence of SSI in individual departments with regular evaluation and presentation of results should form an integral part of these measures.Key words: surgical site infection - incidence - risk factors - prevention - guidelines.

  13. Current Research Status of KHNP for Site Risk

    Energy Technology Data Exchange (ETDEWEB)

    Oh, Kyemin; Jeon, Ho-Jun; Bahng, Ki-In; Na, Jang-Hwan [KHNP CRI, Daejeon (Korea, Republic of)

    2016-10-15

    In Korea, by the geographical characteristics, many Nuclear Power Plants (NPPs) have been constructed and operated at a single site. This is above average level or number of plants per site in the world. For this reason, the public concerns for the safety of nuclear facilities increased after Fukushima Daiichi accident. As a result, comprehensive risk assessment and management for the site which have multi-unit NPPs were strongly asked. Currently, to solve it, many researches and projects has carried out by various Korean companies, research centers, and regulatory authorities. In this paper, R and D plans of KHNP for multi-unit risk were summarized. Firstly, the needs of multi-unit PSA were reviewed. R and D activities and plans of KHNP were summarized in the last part. In this paper, we summarized the R and D plans of KHNP for assessing the multi-unit risk. Currently, multi-unit risk or multi-unit PSA are important and practical issues in both nuclear industry and national energy policy. After Fukushima accident, several countries stopped the construction and the operation of NPPs, other countries which is maintaining the NPPs are being strongly asked to assess the risk for multi-unit NPPs at the same site. Because of Korean geographical characteristics, the number of NPPs which are above average level or number of plants per site in the world is being constructed and operated at a single site. The population density nearby each site is considered to be higher than that of other countries.

  14. Lepton Collider Operation With Constant Currents

    Energy Technology Data Exchange (ETDEWEB)

    Wienands, U.; /SLAC

    2006-02-22

    Electron-positron colliders have been operating in a top-up-and-coast fashion with a cycle time depending on the beam life time, typically one or more hours. Each top-up involves ramping detector systems in addition to the actual filling time. The loss in accumulated luminosity may be 20-50%. During the last year, both B-Factories have commissioned a continuous-injection mode of operation in which beam is injected without ramping the detector, thus raising luminosity integration by always operating at peak luminosity. Constant beam currents also reduce thermal drift and trips caused by change in beam loading. To achieve this level of operation, special efforts were made to reduce the injection losses and also to implement gating procedures in the detectors, minimizing dead time. Beam collimation can reduce injection noise but also cause an increase in background rates. A challenge can be determining beam lifetime, important to maintain tuning of the beams.

  15. ISAC target operation with high proton currents

    CERN Document Server

    Dombsky, M; Schmor, P; Lane, M

    2003-01-01

    The TRIUMF-ISAC facility target stations were designed for ISOL target irradiations with up to 100 mu A proton beam currents. Since beginning operation in 1998, ISAC irradiation currents have progressively increased from initial values of approx 1 mu A to present levels of up to 40 mu A on refractory metal foil targets. In addition, refractory carbide targets have operated at currents of up to 15 mu A for extended periods. The 1-40 mu A operational regime is achieved by tailoring each target to the thermal requirements dictated by material properties such as beam power deposition, thermal conductivity and maximum operating temperature of the target material. The number of heat shields on each target can be varied in order to match the effective emissivity of the target surface for the required radiative power dissipation. Targets of different thickness, surface area and volume have been investigated to study the effect of diffusion and effusion delays on the yield of radioisotopes. For yields of short-lived p...

  16. Geographic and Operational Site Parameters List (GOSPL) for Hanford Assessments

    Energy Technology Data Exchange (ETDEWEB)

    Last, George V.; Nichols, William E.; Kincaid, Charles T.

    2006-06-01

    This data package was originally prepared to support a 2004 composite analysis (CA) of low-level waste disposal at the Hanford Site. The Technical Scope and Approach for the 2004 Composite Analysis of Low Level Waste Disposal at the Hanford Site (Kincaid et. al. 2004) identified the requirements for that analysis and served as the basis for initial preparation of this data package. Completion of the 2004 CA was later deferred, with the 2004 Annual Status Report for the Composite Analysis of Low-Level Waste Disposal in the Central Plateau at the Hanford Site (DOE 2005) indicating that a comprehensive update to the CA was in preparation and would be submitted in 2006. However, the U.S. Department of Energy (DOE) has recently decided to further defer the CA update and will use the cumulative assessment currently under preparation for the environmental impact statement (EIS) being prepared for tank closure and other site decisions as the updated CA. Submittal of the draft EIS is currently planned for FY 2008. This data package describes the facility-specific parameters (e.g. location, operational dates, etc.) used to numerically simulate contaminant flow and transport in large-scale Hanford assessments. Kincaid et al. (2004) indicated that the System Assessment Capability (SAC) (Kincaid et al. 2000; Bryce et al. 2002; Eslinger 2002a, 2002b) would be used to analyze over a thousand different waste sites. A master spreadsheet termed the Geographic and Operational Site Parameters List (GOSPL) was assembled to facilitate the generation of keyword input files containing general information on each waste site/facility, its operational/disposal history, and its environmental settings (past, current, and future). This report briefly describes each of the key data fields, including the source(s) of data, and provides the resulting inputs to be used for large-scale Hanford assessments.

  17. Lepton Collider Operation with Constant Currents

    CERN Document Server

    Wienands, Ulrich

    2005-01-01

    Traditionally, electron-positron colliders have been operating in a top-off-and-coast fashion with a cycle time depending on the beam life time, typically on the order of an hour. Each top-off involves ramping detector systems in addition to the actual filling time. The loss in accumulated luminosity is typically 20-50%. During the last year, both B-Factories have commissioned a continuous-injection mode of operation in which beam is injected without ramping the detector, thus raising luminosity integration by constant operation at peak luminosity. Constant beam currents reduce thermal drift and trips caused by change in beam loading. To achieve this level of operation, special efforts were made to reduce the injection losses and also to implement special gating procedures in the detectors, minimizing dead time. Bunch-injection control decides which bunch to inject into next while maintaining small charge variation between bunches. Beam collimation can reduce injection noise but also cause an increase in back...

  18. Quantum current operators; 3, Commutative quantum current operators semi-infinite construction and functional models

    CERN Document Server

    Ding, J; Ding, Jintai; Feigin, Boris

    1996-01-01

    We construct a commutative current operator $\\bar x^+(z)$ inside $U_q(\\hat{\\frak sl}(2))$. With this operator and the condition of quantum integrability on the quantum current of $U_q(\\hat{\\frak sl}(2))$, we derive the quantization of the semi-infinite construction of integrable modules of The quantization of the functional models for $\\hat{\\frak sl}(2)$ are also given.

  19. Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Potable Water System Operations Plan

    Energy Technology Data Exchange (ETDEWEB)

    Ocampo, Ruben P. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States); Bellah, Wendy [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-03-04

    The existing Lawrence Livermore National Laboratory (LLNL) Site 300 drinking water system operation schematic is shown in Figures 1 and 2 below. The sources of water are from two Site 300 wells (Well #18 and Well #20) and San Francisco Public Utilities Commission (SFPUC) Hetch-Hetchy water through the Thomas shaft pumping station. Currently, Well #20 with 300 gallons per minute (gpm) pump capacity is the primary source of well water used during the months of September through July, while Well #18 with 225 gpm pump capacity is the source of well water for the month of August. The well water is chlorinated using sodium hypochlorite to provide required residual chlorine throughout Site 300. Well water chlorination is covered in the Lawrence Livermore National Laboratory Experimental Test Site (Site 300) Chlorination Plan (“the Chlorination Plan”; LLNL-TR-642903; current version dated August 2013). The third source of water is the SFPUC Hetch-Hetchy Water System through the Thomas shaft facility with a 150 gpm pump capacity. At the Thomas shaft station the pumped water is treated through SFPUC-owned and operated ultraviolet (UV) reactor disinfection units on its way to Site 300. The Thomas Shaft Hetch- Hetchy water line is connected to the Site 300 water system through the line common to Well pumps #18 and #20 at valve box #1.

  20. GIS Operations at the U.S. Department of Energy’s Hanford Site: A Review of the Current Status and a Proposed Action to Ensure Long-Term Data Sustainability

    Energy Technology Data Exchange (ETDEWEB)

    Coleman, Andre M.; Webber, William D.

    2005-07-27

    This paper provides a current state of spatial data collections, use, management, and challenges at the Hanford Site through the use and development of a Spatial Data Infrastructure. Recommendations designed to ensure data quality, usability and sustainability now and into the future are presented.

  1. Current feedback operational amplifiers and their applications

    CERN Document Server

    Senani, Raj; Singh, A K; Singh, V K

    2013-01-01

    This book describes a variety of current feedback operational amplifier (CFOA) architectures and their applications in analog signal processing/generation. Coverage includes a comprehensive survey of commercially available, off-the-shelf integrated circuit CFOAs, as well as recent advances made on the design of CFOAs, including design innovations for bipolar and CMOS CFOAs.  This book serves as a single-source reference to the topic, as well as a catalog of over 200 application circuits which would be useful not only for students, educators and researchers in apprising them about the recent developments in the area but would also serve as a comprehensive repertoire of useful circuits for practicing engineers who might be interested in choosing an appropriate CFOA-based topology for use in a given application.

  2. UAVSAR Instrument: Current Operations and Planned Upgrades

    Science.gov (United States)

    Lou, Yunling; Hensley, Scott; Chao, Roger; Chapin, Elaine; Heavy, Brandon; Jones, Cathleen; Miller, Timothy; Naftel, Chris; Fratello, David

    2011-01-01

    The Uninhabited Aerial Vehicle Synthetic Aperture Radar (UAVSAR) instrument is a pod-based Lband polarimetric synthetic aperture radar (SAR), specifically designed to acquire airborne repeat track SAR data for differential interferometric measurements. This instrument is currently installed on the NASA Gulfstream- III (G-III) aircraft with precision real-time Global Positioning System (GPS) and a sensor-controlled flight management system for precision repeat-pass data acquisitions. UAVSAR has conducted engineering and preliminary science data flights since October 2007 on the G-III. We are porting the radar to the Global Hawk Unmanned Airborne Vehicle (UAV) to enable long duration/long range data campaigns. We plan to install two radar pods (each with its own active array antenna) under the wings of the Global Hawk to enable the generation of precision topographic maps and single pass polarimetric-interferometry (SPI) providing vertical structure of ice and vegetation. Global Hawk's range of 8000 nm will enable regional surveys with far fewer sorties as well as measurements of remote locations without the need for long and complicated deployments. We are also developing P-band polarimetry and Ka-band single-pass interferometry capabilities on UAVSAR by replacing the radar antenna and front-end electronics to operate at these

  3. Surveying the Commons: Current Implementation of Information Commons Web sites

    Science.gov (United States)

    Leeder, Christopher

    2009-01-01

    This study assessed the content of 72 academic library Information Commons (IC) Web sites using content analysis, quantitative assessment and qualitative surveys of site administrators to analyze current implementation by the academic library community. Results show that IC Web sites vary widely in content, design and functionality, with few…

  4. Operational Site Selection for Unmanned Aircraft

    Science.gov (United States)

    2011-06-01

    eliminate unsuitable areas, the Op Site Selection process must first consider landcover , terrain, and specifications for one or more UAS platforms...areas, the OSS process must first consider landcover , terrain, and specifi- cations for one or more UAS platforms. To select the most optimal sites, the...by landcover , ERDC/CERL TR-11-16 2 soil type, slope, and aspect. The individual terrain units are pre- determined and delineated by a separate

  5. The Current and Historical Distribution of Special Status Amphibians at the Livermore Site and Site 300

    Energy Technology Data Exchange (ETDEWEB)

    Hattem, M V; Paterson, L; Woollett, J

    2008-08-20

    65 surveys were completed in 2002 to assess the current distribution of special status amphibians at the Lawrence Livermore National Laboratory's (LLNL) Livermore Site and Site 300. Combined with historical information from previous years, the information presented herein illustrates the dynamic and probable risk that amphibian populations face at both sites. The Livermore Site is developed and in stark contrast to the mostly undeveloped Site 300. Yet both sites have significant issues threatening the long-term sustainability of their respective amphibian populations. Livermore Site amphibians are presented with a suite of challenges inherent of urban interfaces, most predictably the bullfrog (Rana catesbeiana), while Site 300's erosion issues and periodic feral pig (Sus scrofa) infestations reduce and threaten populations. The long-term sustainability of LLNL's special status amphibians will require active management and resource commitment to maintain and restore amphibian habitat at both sites.

  6. Automating ATLAS Computing Operations using the Site Status Board

    CERN Document Server

    Andreeva, J.; Campana, S.; Di Girolamo, A.; Dzhunov, I.; Espinal Curull, X.; Gayazov, S.; Magradze, E.; Nowotka, M.M.; Rinaldi, L.; Saiz, P.; Schovancova, J.; Stewart, G.A.; Wright, M.

    2012-01-01

    The automation of operations is essential to reduce manpower costs and improve the reliability of the system. The Site Status Board (SSB) is a framework which allows Virtual Organizations to monitor their computing activities at distributed sites and to evaluate site performance. The ATLAS experiment intensively uses SSB for the distributed computing shifts, for estimating data processing and data transfer efficiencies at a particular site, and for implementing automatic exclusion of sites from computing activities, in case of potential problems. ATLAS SSB provides a real-time aggregated monitoring view and keeps the history of the monitoring metrics. Based on this history, usability of a site from the perspective of ATLAS is calculated. The presentation will describe how SSB is integrated in the ATLAS operations and computing infrastructure and will cover implementation details of the ATLAS SSB sensors and alarm system, based on the information in SSB. It will demonstrate the positive impact of the use of SS...

  7. Automating ATLAS Computing Operations using the Site Status Board

    CERN Document Server

    Andreeva, J; The ATLAS collaboration; Campana, S; Di Girolamo, A; Espinal Curull, X; Gayazov, S; Magradze, E; Nowotka, MM; Rinaldi, L; Saiz, P; Schovancova, J; Stewart, GA; Wright, M

    2012-01-01

    The automation of operations is essential to reduce manpower costs and improve the reliability of the system. The Site Status Board (SSB) is a framework which allows Virtual Organizations to monitor their computing activities at distributed sites and to evaluate site performance. The ATLAS experiment intensively uses SSB for the distributed computing shifts, for estimating data processing and data transfer efficiencies at a particular site, and for implementing automatic exclusion of sites from computing activities, in case of potential problems. ATLAS SSB provides a real-time aggregated monitoring view and keeps the history of the monitoring metrics. Based on this history, usability of a site from the perspective of ATLAS is calculated. The presentation will describe how SSB is integrated in the ATLAS operations and computing infrastructure and will cover implementation details of the ATLAS SSB sensors and alarm system, based on the information in SSB. It will demonstrate the positive impact of the use of SS...

  8. Heating a chemical current source which operates at low temperature

    Energy Technology Data Exchange (ETDEWEB)

    Mitsumata, T.; Khosikhara, N.

    1983-02-14

    A chamber for catalytic ignition of hydrogen or gasoline is installed in a chemical current source. The isolated heat heats the chemical current source with a low temperature of the environment providing its optimal operational conditions. The fuel is fed into the chamber from a tank or chamber located in the body of the chemical current source.

  9. Human Mars Landing Site and Impacts on Mars Surface Operations

    Science.gov (United States)

    Hoffman, Stephen J.; Bussey, Ben

    2016-01-01

    This paper describes NASA's initial steps for identifying and evaluating candidate Exploration Zones (EZs) and Regions of Interests (ROIs) for the first human crews that will explore the surface of Mars. NASA's current effort to define the exploration of this planet by human crews, known as the Evolvable Mars Campaign (EMC), provides the context in which these EZs and ROIs are being considered. The EMC spans all aspects of a human Mars mission including launch from Earth, transit to and from Mars, and operations on the surface of Mars. An EZ is a collection of ROIs located within approximately 100 kilometers of a centralized landing site. ROIs are areas relevant for scientific investigation and/or development/maturation of capabilities and resources necessary for a sustainable human presence. The EZ also contains one or more landing sites and a habitation site that will be used by multiple human crews during missions to explore and utilize the ROIs within the EZ. With the EMC as a conceptual basis, the EZ model has been refined to a point where specific site selection criteria for scientific exploration and in situ resource utilization can be defined. In 2015 these criteria were distributed to the planetary sciences community and the in situ resource utilization and civil engineering communities as part of a call for EZ proposals. The resulting "First Landing Site/Exploration Zone Workshop for Human Missions to the Surface of Mars" was held in October 2015 during which 47 proposals for EZs and ROIs were presented and discussed. Proposed locations spanned all longitudes and all allowable latitudes (+/- 50 degrees). Proposed justification for selecting one of these EZs also spanned a significant portion of the scientific and resource criteria provided to the community. Several important findings resulted from this Workshop including: (a) a strong consensus that, at a scale of 100 km (radius), multiple places on Mars exist that have both sufficient scientific interest

  10. Difference equations of quantum current operators and quantum parafermion construction

    CERN Document Server

    Ding, J; Ding, Jintai; Feigin, Boris

    1996-01-01

    For the current realization of the affine quantum groups, a simple comultiplication for the quantum current operators was given by Drinfeld. With this comultiplication, we prove that, for the integrable modules of $U_q(\\hat x^\\pm(zq^{\\pm 2k})$ are vertex operators satisfying certain q-difference equations, and we derive the quantum parafermions of $U_q(\\hat {\\frak sl}(2))$.

  11. A Survey on the Image Retrieval via Site Operator

    Directory of Open Access Journals (Sweden)

    Saleh Rahimi

    2015-12-01

    Full Text Available The purpose of the present study is to investigate the Impact of Image Indexing on Optimizing Image Retrieval via site operator. Using quasi-experimental method 100 images, each image was uploaded 9 times with concept-based characteristics on iiproject.ir. Analysis consists of images which retrieved from the site operator. Number of images retrieved by the site operator is 151 images of 900 ones that are used in this study. The minimum number of retrieved images is related to "image titles" and the maximum ones to the criteria images which entitled with Q code. Chi-square statistics showed that the number of images retrieved in various codes was different. The best ranking is related to “image title” and the weakest one related to “image caption in Farsi”. Images average ranking retrieved in 9 groups were different.

  12. Surgical site infection prevention: the operating room environment.

    Science.gov (United States)

    Clyburn, Terry A; Evans, Richard P; Moucha, Calin S; Prokuski, Laura

    2011-01-01

    Surgical site infections can complicate orthopaedic procedures and contribute to morbidity, mortality, and health care costs. Extensive literature has been published on this topic; however, the quality of data using standards of evidence-based medicine is variable with a lack of well-controlled studies. A review of the literature concerning measures to prevent surgical site infections in the operating room environment may be helpful in preventing such infections.

  13. Overview of Low-Level Waste Disposal Operations at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    DOE/Navarro

    2007-02-01

    The U.S. Department of Energy, National Nuclear Security Administration Nevada Site Office Environmental Management Program is charged with the responsibility to carry out the disposal of on-site and off-site generated low-level radioactive waste at the Nevada Test Site. Core elements of this mission are ensuring that disposal take place in a manner that is safe and cost-effective while protecting workers, the public, and the environment. This paper focuses on giving an overview of the Nevada Test Site facilities regarding currant design of disposal. In addition, technical attributes of the facilities established through the site characterization process will be further described. An update on current waste disposal volumes and capabilities will also be provided. This discussion leads to anticipated volume projections and disposal site requirements as the Nevada Test Site disposal operations look towards the future.

  14. Current operators in relativistic few-body systems

    Energy Technology Data Exchange (ETDEWEB)

    Coester, F.; Klink, W.H.; Polyzou, W.N.

    1995-08-01

    The interpretation of experiments that explore hadron structure with electromagnetic probes requires both a nonperturbative representation of the hadron states and a compatible representation of the current-density operator. Intuitive interpretations depend strongly on the {open_quotes}impulse approximation{close_quotes}, that is, the use of one-body currents. One-body currents, however, cannot satisfy essentially the constraints imposed by the dynamics. In nonrelativistic quantum mechanics the problem of constructing dynamically required interaction currents is well understood and has been solved. Since Galilei transformations are kinematic, only time-translation covariance and current conservation impose dynamical constraints on current operators. These constraints can be satisfied by the well-known construction of so-called {open_quotes}minimal{close_quotes} or {open_quotes}model-independent{close_quotes} currents. Descriptions of hadron structure and of nuclear effects probed at high energies require a relativistic description. In relativistic few-body dynamics, one-body currents are covariant only under the kinematic subgroup of the Poincare group. Full Poincare covariance and current conservation implies dynamically determined interaction currents. The separation of the current operator into impulse current and interaction current depends on the {open_quotes}form of dynamics{close_quotes}, that is on the choice of the kinematic subgroup. The choice of the light-front kinematics has unique advantages not available with other forms of dynamics: (1) a relevant subgroup of the translations is kinematic, (2) initial and final states are related by kinematic Lorentz transformations, (3) the contributions of the individual constituents are related kinematically to the total current. These features were exploited successfully in calculations of deuteron form factors and quark-model form factors of hadrons.

  15. Electric and hybrid vehicle program; Site Operator Program

    Energy Technology Data Exchange (ETDEWEB)

    Warren, J.F.

    1992-05-01

    Activities during the second quarter included the second meeting of the Site Operators in Phoenix, AZ in late April. The meeting was held in conjunction with the Solar and Electric 500 Race activities. Delivery of vehicles ordered previously has begun, although two of the operators are experiencing some delays in receiving their vehicles. Public demonstration activities continue, with an apparent increasing level of awareness and interest being displayed by the public. Initial problems with the Site Operator Database have been corrected and revised copies of the program have been supplied to the Program participants. Operating and Maintenance data is being supplied and submitted to INEL on a monthly basis. Interest in the Site Operator Program is being reflected in requests for information from several organizations from across the country, representing a wide diversity of interests. These organizations have been referred to existing Site Operators with the explanation that the program will not be adding new participants, but that most of the existing organizations are willing to work with other groups. The exception to this was the addition of Potomac Electric Power Company (PEPCO) to the program. PEPCO has been awarded a subcontract to operate and maintain the DOE owned G-Van and Escort located in Washington, DC. They will provide data on these vehicles, as well as a Solectria Force which PEPCO has purchased. The Task Force intends to be actively involved in the infrastructure development in a wide range of areas. These include, among others, personnel development, safety, charging, and servicing. Work continues in these areas. York Technical College (YORK) has completed the draft outline for the EV Technician course. This is being circulated to organizations around the country for comments. Kansas State University (KSU) is working with a private sector company to develop a energy dispensing meter for opportunity charging in public areas.

  16. Electric and hybrid vehicle program; Site Operator Program

    Science.gov (United States)

    Warren, J. F.

    1992-05-01

    Activities during the second quarter included the second meeting of the Site Operators in Phoenix, AZ in late April. The meeting was held in conjunction with the Solar and Electric 500 Race activities. Delivery of vehicles ordered previously has begun, although two of the operators are experiencing some delays in receiving their vehicles. Public demonstration activities continue, with an apparent increasing level of awareness and interest being displayed by the public. Initial problems with the Site Operator Database have been corrected and revised copies of the program have been supplied to the program participants. Operating and Maintenance data is being supplied and submitted to INEL on a monthly basis. Interest in the Site Operator Program is being reflected in requests for information from several organizations from across the country, representing a wide diversity of interests. These organizations have been referred to existing Site Operators with the explanation that the program will not be adding new participants, but that most of the existing organizations are willing to work with other groups. The exception to this was the addition of Potomac Electric Power Company (PEPCO) to the program. PEPCO has been awarded a subcontract to operate and maintain the DOE owned G-Van and Escort located in Washington, DC. They will provide data on these vehicles, as well as a Solectria Force which PEPCO has purchased. The Task Force intends to be actively involved in the infrastructure development in a wide range of areas. These include, among others, personnel development, safety, charging, and servicing. Work continues in these areas. York Technical College (YORK) has completed the draft outline for the EV Technician course. This is being circulated to organizations around the country for comments. Kansas State University (KSU) is working with a private sector company to develop a energy dispensing meter for opportunity charging in public areas.

  17. Current Approaches for the Prevention of Surgical Site Infections

    Directory of Open Access Journals (Sweden)

    Sander Florman

    2007-01-01

    Full Text Available Surgical site infections (SSIs are the most common type of nosocomial infection among surgical patients and are commonly caused by the patients’ own microbial flora. The prevalence of SSI is a major concern because of the associated increase in the incidence of morbidity and mortality, length of hospitalization and cost of care for postoperative patients. Key factors that determine whether patients are at risk for developing SSI include the inherent potential contamination of the surgical site, the duration of the operation and the individual patient susceptibility. Preventive preoperative measures that can reduce the risk of SSIs include administration of antimicrobial prophylaxis, proper utilization of skin antiseptic agents for both the patient and the surgical team, proper patient preoperative hair removal and the policy of canceling elective procedures when remote skin, urinary or pulmonary infections occur. This paper will review the efficacy and safety of available antiseptic agents, as well as discuss patient-specific prevention strategies.

  18. Environmental analysis of the operation of Oak Ridge National Laboratory (X-10 site)

    Energy Technology Data Exchange (ETDEWEB)

    Boyle, J.W.; Blumberg, R.; Cotter, S.J.

    1982-11-01

    An environmental analysis of the operation of the Oak Ridge National Laboratory (ORNL) facilities in Bethel Valley and Melton Valley was conducted to present to the public information concerning the extent to which recognizable effects, or potential effects, on the environment may occur. The analysis addresses current operations of the ORNL X-10 site and completed operations that may continue to have residual effects. Solid wastes from ORNL operations at the Y-12 site which are transported to the X-10 site for burial (e.g., Biology Division animal wastes) are included as part of X-10 site operation. Socioeconomic effects are associated primarily with the communities where employees live and with the Knoxville Bureau of Economic Analysis economic area as a whole. Therefore, ORNL employees at both Y-12 and X-10 sites are included in the ORNL socioeconomic impact analysis. An extensive base of environmental data was accumulated for this report. Over 80 reports related to ORNL facilities and/or operations are cited as well as many open-literature citations. Environmental effects of the operation of ORNL result from operational discharges from the onsite facilities; construction and/or modification of facilities, transportation to and from the site of persons, goods and services; socioeconomic impacts to the local, regional, and general population; and accidental discharges if they should occur. Operational discharges to the environnment are constrained by federal, state, and local regulations and by criteria established by the US Department of Energy to minimize adverse impacts. It is the purpose of this document to evaluate the operation of the ORNL insofar as impacts beyond the site boundary may occur or have the potential for occurrence.

  19. Current activities handbook: formerly utilized sites remedial action program

    Energy Technology Data Exchange (ETDEWEB)

    None

    1981-02-27

    This volume is one of a series produced under contract with the DOE, by Politech Corporation to develop a legislative and regulatory data base to assist the FUSRAP management in addressing the institutional and socioeconomic issues involved in carrying out the Formerly Utilized Sites Remedial Action Program. This Information Handbook series contains information about all relevant government agencies at the Federal and state levels, the pertinent programs they administer, each affected state legislature, and current Federal and state legislative and regulatory initiatives. This volume is a compilation of information about the activities each of the thirteen state legislatures potentially affected by the Formerly Utilized Sites Remedial Action Program. It contains a description of the state legislative procedural rules and a schedule of each legislative session; a summary of pending relevant legislation; the name and telephone number of legislative and state agency contacts; and the full text of all bills identified.

  20. Electric and Hybrid Vehicle Program, Site Operator Program. Quarterly progress report, January--March 1996

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.E. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States); Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Briasco, S. [Los Angeles City Dept. of Water and Power, CA (United States)] [and others

    1996-08-01

    Goals of the site operator program include field evaluation of electric vehicles (EVs) in real-world applications and environments, advancement of electric vehicle technologies, development of infrastructure elements necessary to support significant EV use, and increasing the awareness and acceptance of EVs by the public. The site operator program currently consists of 11 participants under contract and two other organizations with data-sharing agreements with the program. The participants (electric utilities, academic institutions, Federal agencies) are geographically dispersed within US and their vehicles see a broad spectrum of service conditions. Current EV inventories of the site operators exceeds 250 vehicles. Several national organizations have joined DOE to further the introduction and awareness of EVs, including: (1) EVAmerica (a utility program) and DOE conduct performance and evaluation tests to support market development for EVs; (2) DOE, DOT, the Electric Transportation Coalition, and the Electric Vehicle Association of the Americas are conducting a series of workshops to encourage urban groups in Clean Cities (a DOE program) to initiate the policies and infrastructure development necessary to support large-scale demonstrations, and ultimately the mass market use, of EVs. Current focus of the program is collection and dissemination of EV operations and performance data to aid in the evaluation of real- world EV use. This report contains several sections with vehicle evaluation as a focus: EV testing results, energy economics of EVs, and site operators activities.

  1. Surgical site infections in paediatric otolaryngology operative procedures.

    Science.gov (United States)

    Ifeacho, S N; Bajaj, Y; Jephson, C G; Albert, D M

    2012-07-01

    An assessment of the rate of surgical site infections associated with elective paediatric otolaryngology surgical procedures. Prospective data was collected for a 3-week period for all children undergoing surgery where either mucosa or skin was breached. The parents of the children were requested to complete a questionnaire at 30 days after the operation. Data was collected on 80 consecutive cases. The majority of cases were admitted on the day of the procedure. The procedures included adenotonsillectomy (24), grommets (12), cochlear implantation (6), bone-anchored hearing aid (2), submandibular gland excision (1), branchial sinus excision (1), cystic hygroma excision (3), nasal glioma excision (1), microlaryngobronchoscopy (13), tracheostomy (3) and other procedures (14). Nearly half the cases had more than one operation done at the same time. 26/80 (32.5%) patients had a temporary or permanent implant inserted at the time of operation (grommet, bone-anchored hearing aid, cochlear implant). 25/80 (31%) operative fields were classed as clean and 55/80 (68.7%) as clean contaminated operations. The duration of the operation varied from 6 min to 142 min. Hospital antibiotic protocol was adhered to in 69/80 (86.3%) cases but not in 11/80 cases. In our series, 3/80 (3.7%) patients had an infection in the postoperative period. Surgical site infections do occur at an appreciable rate in paediatric otolaryngology. With the potential for serious consequences, reduction in the risk of surgical site infections is important. Copyright © 2012 Elsevier Ireland Ltd. All rights reserved.

  2. Quantization of edge currents for continuous magnetic operators

    CERN Document Server

    Kellendonk, J

    2003-01-01

    For a magnetic Hamiltonian on a half-plane given as the sum of the Landau operator with Dirichlet boundary conditions and a random potential, a quantization theorem for the edge currents is proven. This shows that the concept of edge channels also makes sense in presence of disorder. Moreover, gaussian bounds on the heat kernel and its covariant derivatives are obtained.

  3. Towards fully non-inductive current drive operation in JET

    Energy Technology Data Exchange (ETDEWEB)

    Litaudon, X. [Association Euratom-CEA Cadarache, Dept. de Recherches sur la Fusion Controlee, 13 - Saint-Paul-lez-Durance (France); Crisanti, F. [Association Euratom-ENEA sulla Fusione, Centro Ricerche Frascati (Italy); Alper, B. [Euratom-UKAEA Fusion Association, Culham Science Centre, Abingdon, Oxon (United Kingdom)] [and others

    2002-01-01

    Quasi steady operation has been achieved at JET in the high confinement regime with Internal Transport Barriers, ITBs. The ITBs' performances are maintained up to 11 s. This duration, much larger than the energy confinement time, is already approaching a current resistive time. The high performance phase is limited only by plant constraints. The radial profiles of the thermal electron and ion pressures have steep gradients typically at mid-plasma radius. A large fraction of non-inductive current (above 80%) is sustained throughout the high performance phase with a poloidal beta exceeding unity. The safety factor profile plays an important role in sustaining the ITB characteristics. In this regime where the self-generated bootstrap current (up to LOMA) represents 50% of the total current, the resistive evolution of the non-monotonic q-profile is slowed down by using off-axis lower hybrid current drive. (authors)

  4. Operator algebra of free conformal currents via twistors

    Energy Technology Data Exchange (ETDEWEB)

    Gelfond, O.A. [Institute of System Research of Russian Academy of Sciences, Nakhimovsky prospect 36-1, 117218 Moscow (Russian Federation); Vasiliev, M.A., E-mail: vasiliev@lpi.ru [I.E. Tamm Department of Theoretical Physics, Lebedev Physical Institute, Leninsky prospect 53, 119991 Moscow (Russian Federation)

    2013-11-21

    Operator algebra of (not necessarily free) higher-spin conformal conserved currents in generalized matrix spaces, that include 3d Minkowski space–time as a particular case, is shown to be determined by an associative algebra M of functions on the twistor space. For free conserved currents, M is the universal enveloping algebra of the higher-spin algebra. Proposed construction greatly simplifies computation and analysis of correlators of conserved currents. Generating function for n-point functions of 3d (super)currents of all spins, built from N free constituent massless scalars and spinors, is obtained in a concise form of certain determinant. Our results agree with and extend earlier bulk computations in the HS AdS{sub 4}/CFT{sub 3} framework. Generating function for n-point functions of 4d conformal currents is also presented.

  5. A Comprehensive Comparison of Current Operating Reserve Methodologies

    Energy Technology Data Exchange (ETDEWEB)

    Krad, Ibrahim; Ibanez, Eduardo; Gao, Wenzhong

    2016-05-05

    Electric power systems are currently experiencing a paradigm shift from a traditionally static system to a system that is becoming increasingly more dynamic and variable. Emerging technologies are forcing power system operators to adapt to their performance characteristics. These technologies, such as distributed generation and energy storage systems, have changed the traditional idea of a distribution system with power flowing in one direction into a distribution system with bidirectional flows. Variable generation, in the form of wind and solar generation, also increases the variability and uncertainty in the system. As such, power system operators are revisiting the ways in which they treat this evolving power system, namely by modifying their operating reserve methodologies. This paper intends to show an in-depth analysis on different operating reserve methodologies and investigate their impacts on power system reliability and economic efficiency.

  6. Operating theatre quality and prevention of surgical site infections.

    Science.gov (United States)

    Spagnolo, A M; Ottria, G; Amicizia, D; Perdelli, F; Cristina, M L

    2013-09-01

    Surgical site infections (SSI) account for 14% to 17% of all hospital-acquired infections and 38% of nosocomial infections in surgical patients. SSI remain a substantial cause of morbidity and death, possibly because of the larger numbers of elderly surgical patients or those with a variety of chronic and immunocompromising conditions, and emergence of antibiotic-resistant microorganisms. Factors causing surgical site infection are multifarious. Several studies have identified the main patient-related (endogenous risk factors) and procedure-related (external risk factors) factors that influence the risk of SSI. The rate of surgical wound infections is strongly influenced by operating theatre quality, too. A safe and salubrious operating theatre is an environment in which all sources of pollution and any micro-environmental alterations are kept strictly under control. This can be achieved only through careful planning, maintenance and periodic checks, as well as proper ongoing training for staff Many international scientific societies have produced guidelines regarding the environmental features of operating theatres (positive pressure, exchanges of filtered air per hour, air-conditioning systems with HEPA filters, etc.) and issued recommendations on healthcare-associated infection, including SSI, concerning surveillance methods, intervention to actively prevent SSI and approaches to monitoring the implementation of such strategies. Therefore, the prevention of SSI requires a multidisciplinary approach and the commitment of all concerned, including that of those who are responsible for the design, layout and functioning of operating theatres.

  7. Design Considerations for CMOS Current Mode Operational Amplifiers and Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    This dissertation is about CMOS current conveyors and current mode operational amplifiers (opamps). They are generic devices for continuous time signal processing in circuits and systems where signals are represented by currents.Substantial advancements are reported in the dissertation, both...... related to circuit implementations and system configurations and to an analysis of the fundamental limitations of the current mode technique.In the field of system configurations and circuit implementations different configurations of high gain current opamps are introduced and some of the first...... implementations of current mode opamps in CMOS technology are described. Also, current conveyor configurations with multiple outputs and flexible feedback connections from outputs to inputs are introduced. The dissertation includes several examples of circuit configurations ranging from simple class A and class...

  8. Nuclear electromagnetic charge and current operators in Chiral EFT

    Energy Technology Data Exchange (ETDEWEB)

    Girlanda, Luca [Università del Salento; Marcucci, Laura Elisa [Univ. Pisa; Pastore, Saori [Department of Physics and Astronomy, University of South Carolina, Columbia, SC; Piarulli, Maria [Department of Physics, Old Dominion University, Norfolk, VA; Schiavilla, Rocco [Old Dominion U., JLAB; Viviani, Michele

    2013-08-01

    We describe our method for deriving the nuclear electromagnetic charge and current operators in chiral perturbation theory, based on time-ordered perturbation theory. We then discuss possible strategies for fixing the relevant low-energy constants, from the magnetic moments of the deuteron and of the trinucleons, and from the radiative np capture cross sections, and identify a scheme which, partly relying on {Delta} resonance saturation, leads to a reasonable pattern of convergence of the chiral expansion.

  9. Design Considerations for CMOS Current Mode Operational Amplifiers and Current Conveyors

    DEFF Research Database (Denmark)

    Bruun, Erik

    This dissertation is about CMOS current conveyors and current mode operational amplifiers (opamps). They are generic devices for continuous time signal processing in circuits and systems where signals are represented by currents.Substantial advancements are reported in the dissertation, both...... implementations of current mode opamps in CMOS technology are described. Also, current conveyor configurations with multiple outputs and flexible feedback connections from outputs to inputs are introduced. The dissertation includes several examples of circuit configurations ranging from simple class A and class...... AB conveyor implementations to implementations based on purely digital circuit structures and on more complex analog subsystems such as a voltage mode opamp with feedback to provide a voltage follower action. An important by-product of the investigation of current mode structures is the definition...

  10. Gas Hydrate Research Site Selection and Operational Research Plans

    Science.gov (United States)

    Collett, T. S.; Boswell, R. M.

    2009-12-01

    In recent years it has become generally accepted that gas hydrates represent a potential important future energy resource, a significant drilling and production hazard, a potential contributor to global climate change, and a controlling factor in seafloor stability and landslides. Research drilling and coring programs carried out by the Ocean Drilling Program (ODP), the Integrated Ocean Drilling Program (IODP), government agencies, and several consortia have contributed greatly to our understanding of the geologic controls on the occurrence of gas hydrates in marine and permafrost environments. For the most part, each of these field projects were built on the lessons learned from the projects that have gone before them. One of the most important factors contributing to the success of some of the more notable gas hydrate field projects has been the close alignment of project goals with the processes used to select the drill sites and to develop the project’s operational research plans. For example, IODP Expedition 311 used a transect approach to successfully constrain the overall occurrence of gas hydrate within the range of geologic environments within a marine accretionary complex. Earlier gas hydrate research drilling, including IODP Leg 164, were designed primarily to assess the occurrence and nature of marine gas hydrate systems, and relied largely on the presence of anomalous seismic features, including bottom-simulating reflectors and “blanking zones”. While these projects were extremely successful, expeditions today are being increasingly mounted with the primary goal of prospecting for potential gas hydrate production targets, and site selection processes designed to specifically seek out anomalously high-concentrations of gas hydrate are needed. This approach was best demonstrated in a recently completed energy resource focused project, the Gulf of Mexico Gas Hydrate Joint Industry Project Leg II (GOM JIP Leg II), which featured the collection of a

  11. Two-loop current-current operator contribution to the non-leptonic QCD penguin amplitude

    CERN Document Server

    Bell, Guido; Huber, Tobias; Li, Xin-Qiang

    2015-01-01

    The computation of direct CP asymmetries in charmless B decays at next-to-next-to-leading order (NNLO) in QCD is of interest to ascertain the short-distance contribution. Here we compute the two-loop penguin contractions of the current-current operators Q_{1,2} and provide a first estimate of NNLO CP asymmetries in penguin-dominated b -> s transitions.

  12. Site Operator technical report. Final report (1992--1996)

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    The Southern California Edison Company (SCE) and the US Department of Energy (DOE) entered into cooperative agreement No. DE-FC07-91ID13077 on August 23, 1991, which expired on August 3, 1996. This cooperative agreement provided SCE with DOE cofunding for participation in the DOE`s Electric and Hybrid Vehicle Site Operator Program. In return, SCE provided the DOE with quarterly progress reports which include operating and maintenance data for the electric (EVs) vehicles in SCE`s fleet. Herein is SCE`s final report for the 1992 to 1996 agreement period. As of September 1, 1996 the SCE fleet had 65 electric vehicles in service. A total of 578,200 miles had been logged. During the agreement period, SCE sent the DOE a total of 19 technical reports (Appendix B). This report summarizes the technical achievements which took place during a long, productive and rewarding, relationship with the DOE.

  13. Operative Duration and Risk of Surgical Site Infection in Neurosurgery.

    Science.gov (United States)

    Bekelis, Kimon; Coy, Shannon; Simmons, Nathan

    2016-10-01

    The association of surgical duration with the risk of surgical site infection (SSI) has not been quantified in neurosurgery. We investigated the association of operative duration in neurosurgical procedures with the incidence of SSI. We performed a retrospective cohort study involving patients who underwent neurosurgical procedures from 2005 to 2012 and were registered in the American College of Surgeons National Quality Improvement Project registry. To control for confounding, we used multivariable regression models and propensity score conditioning. During the study period there were 94,744 patients who underwent a neurosurgical procedure and met the inclusion criteria. Of these patients, 4.1% developed a postoperative SSI within 30 days. Multivariable logistic regression showed an association between longer operative duration with higher incidence of SSI (odds ratio [OR], 1.18; 95% confidence interval [CI], 1.16-1.20). Compared with procedures of moderate duration (third quintile, 40th-60th percentile), patients undergoing the longest procedures (>80th percentile) had higher odds (OR, 2.07; 95% CI, 1.86-2.31) of developing SSI. The shortest procedures (surgical registry, longer operative duration was associated with increased incidence of SSI for neurosurgical procedures. These results can be used by neurosurgeons to inform operative management and to stratify patients with regard to SSI risk. Copyright © 2016 Elsevier Inc. All rights reserved.

  14. Shaft Siting and Configuration for Flexible Operating Mode

    Energy Technology Data Exchange (ETDEWEB)

    Robert Boutin

    2001-08-02

    The purpose of this document as stated in the ''Technical Work Plan for Subsurface Design Section FY 01 Work Activities'' (CRWMS M&O 2001a, pg. 14) is to review and evaluate the most current concepts for shaft siting and configuration. The locations of the shaft sites will be evaluated in reference to the overall subsurface ventilation layout shown in Figure 1. The scope will include discussions on pad size requirements, shaft construction components such as collars, shaft stations, sumps, ground support and linings, head frames, fan ducting and facility equipping. In addition to these, shaft excavation methodologies and integration with the overall subsurface construction schedule will be described. The Technical Work Plan (TWP), (CRWMS M&O 2001a), for this document has been prepared in accordance with AP-2.21Q, ''Quality Determinations and Planning for Scientific, Engineering and Regulatory Compliance Activities''. This document will be prepared in accordance with AP-3.10Q, ''Analysis and Models''. This document contributes to Site Recommendation (SR). The intended use of this document is to provide an analysis for shaft siting and configuration criteria for subsequent construction. This document identifies preliminary design concepts that should not be used for procurement, fabrication, or construction.

  15. The Phoenix Mission and its Current Landing Site options

    Science.gov (United States)

    Tamppari, LK; Smith, P.; Arvidson, RE; Phoenix Team

    2005-08-01

    Phoenix is the 2007 Mars Scout program mission that will send a lander and suite of instruments to study the north polar region on Mars. Central goals for the Phoenix mission are to study the recent history of water as written into the high latitude soils and to search for habitable zones. In order to do this, Phoenix carries a comprehensive suite of seven instruments. This suite includes 3 cameras, an optical microscope and an atomic-force microscope, allowing imaging at spatial scales ranging from kms, for large scale geomorphological studies, to microns, for examining single grain sizes and shapes. Phoenix also has a meteorology suite, which includes atmospheric temperature measurements at 3 levels, atmospheric pressure, and an upward-looking lidar, for dust and water-ice cloud detection. A robotic arm will dig a trench into the surface near the lander to collect and deliver samples to on-board chemistry and mineralogy experiments. These experiments will allow the detection of the mineral makeup of the soil as well as its water content, pH, salt content, and organic content. An important aspect of this exciting mission is the selection of the landing site, within the 65-72 deg N latitude band. Both science and safety concerns will play into this selection. Work is ongoing to determine the most favorable location, with consideration focusing on the best ice/soil ratio, the shallowest slopes and fewest large rocks. Current sites under consideration will be discussed. Selected in 2003, Phoenix was recently confirmed to proceed into Phase C/D of spacecraft development. This research was funded by a NASA Grant and carried out by the Jet Propulsion Laboratory, California Institute of Technology.

  16. Higher-spin current multiplets in operator-product expansions

    CERN Document Server

    Anselmi, D

    2000-01-01

    Various formulas for currents with arbitrary spin are worked out in general space-time dimension, in the free field limit and, at the bare level, in presence of interactions. As the n-dimensional generalization of the (conformal) vector field, the (n/2-1)-form is used. The two-point functions and the higher-spin central charges are evaluated at one loop. As an application, the higher-spin hierarchies generated by the stress-tensor operator-product expansion are computed in supersymmetric theories. The results exhibit an interesting universality.

  17. Design of current mirror integration ROIC for snapshot mode operation

    Science.gov (United States)

    Shanker Gupta, Hari; Kiran Kumar, A. S.; Shojaei Baghini, M.; Chakrabarti, Subhananda; Mehta, Sanjeev; Chowdhury, Arup Roy; Sharma, Dinesh K.

    2016-10-01

    Current mirror integration (CMI) read out integrated circuit (ROIC) topology provides a low input impedance to photo-detectors and provides large injection efficiency, large charge handling capacity and snapshot mode operation without in-pixel opamps. The ROIC described in this paper has been implemented with a modified current mirror circuit, with matched PMOS pairs for detector input stage and its biasing. The readout circuit has been designed for 30 × 30 μm2 pixel size, 4 × 4 array size, variable frame rate, 5 Mega pixel per second (Mpps). Experimental performance of the test chip has achieved 15 Me charge handling capacity, a high dynamic range of 83 dB, 99.8% linearity and 99.96% injection efficiency. The ROIC design has been fabricated in 3.3 V 1P6M UMC 180 nm CMOS process and tested up to 5 MHz pixel rate at room and at cryogenic temperature.

  18. Current practices for maintaining occupational exposures ALARA at low-level waste disposal sites

    Energy Technology Data Exchange (ETDEWEB)

    Hadlock, D.E.; Herrington, W.N.; Hooker, C.D.; Murphy, D.W.; Gilchrist, R.L.

    1983-12-01

    The United States Nuclear Regulatory Commission contracted with Pacific Northwest Laboratory (PNL) to provide technical assistance in establishing operational guidelines, with respect to radiation control programs and methods of minimizing occupational radiation exposure, at Low-Level Waste (LLW) disposal sites. The PNL, through site visits, evaluated operations at LLW disposal sites to determine the adequacy of current practices in maintaining occupational exposures as low as is reasonably achievable (ALARA). The data sought included the specifics of: ALARA programs, training programs, external exposure control, internal exposure control, respiratory protection, surveillance, radioactive waste management, facilities and equipment, and external dose analysis. The results of the study indicated the following: The Radiation Protection and ALARA programs at the three commercial LLW disposal sites were observed to be adequate in scope and content compared to similar programs at other types of nuclear facilities. However, it should be noted that there were many areas that could be improved upon to help ensure the health and safety of occupationally exposed individuals.

  19. [Robotic single site surgery: current practice and future developments].

    Science.gov (United States)

    Buchs, N C; Pugin, F; Volonté, F; Jung, M; Hagen, M E; Morel, P

    2012-06-20

    Robotic surgery has been gaining increasing acceptance for several years now, establishing itself with success in all the surgical fields. Besides, since the introduction of single site surgery, the interest for the robotic technology is more than obvious, offering technical possibilities to overcome the natural limitations of laparoscopy. This article reviews the different devices available and the indications of robotic single site surgery. Moreover, the future developments of this new technology are discussed as well.

  20. [Current operative techniques and strategies in endocrine surgery].

    Science.gov (United States)

    Gürtler, Thomas; Weber, Markus

    2011-06-01

    Technical advances and focusing on subsets modified endocrine surgery in the last ten years tremendously. There is on one side a clear trend towards minimal invasive approaches, first of all in the surgery of the adrenal glands, where the transperitoneal or retroperitoneal laparoscopic adrenalectomy has become the gold standard for tumors up to a size of 10 cm in diameter. But also in pancreatic endocrine surgery for small tumors localized in the pancreas tail and up to a certain extend in thyroid and parathyroid surgery, laparoscopic or video assisted techniques are used. On the other side more precise techniques allow a more complete and radical removal of endocrine tissue, especially in thyroid surgery. This article presents a summary of current operative techniques and strategies in endocrine surgery.

  1. 36 CFR 6.5 - Solid waste disposal sites in operation on September 1, 1984.

    Science.gov (United States)

    2010-07-01

    ... 36 Parks, Forests, and Public Property 1 2010-07-01 2010-07-01 false Solid waste disposal sites in..., DEPARTMENT OF THE INTERIOR SOLID WASTE DISPOSAL SITES IN UNITS OF THE NATIONAL PARK SYSTEM § 6.5 Solid waste disposal sites in operation on September 1, 1984. (a) The operator of a solid waste disposal site...

  2. Loch Linnhe `94: Test operations description and on-site analysis, US activities

    Energy Technology Data Exchange (ETDEWEB)

    Mantrom, D.D.

    1994-11-01

    A field experiment named Loch Linnhe `94 (LL94) is described. This experiment was conducted in upper Loch Linnhe, Scotland, in September 1994, as an exercise involving UK and US investigators, under the Joint UK/US Radar Ocean Imaging Program. This experiment involved a dual-frequency, dual-polarization hillside real aperture radar operated by the UK, Lawrence Livermore National Laboratory`s (LLNL) current meter array (CMA), in-water hydrodynamic sensors, and meteorological measurements. The primary measurements involved imaging ship-generated and ambient internal waves by the radar and the CMA. This report documents test operations from a US perspective and presents on-site analysis results derived by US investigators. The rationale underlying complementary radar and CMA measurements is described. Descriptions of the test site, platforms, and major US instrument systems are given. A summary of test operations and examples of radar, CMA, water column profile, and meteorological data are provided. A description of the rather extensive analysis of these data performed at the LL94 test site is presented. The products of this analysis are presented and some implications for further analysis and future experiments are discussed. All experimental objectives were either fully or partially met. Powerful on-site analysis capabilities generated many useful products and helped improve subsequent data collection. Significant further data analysis is planned.

  3. 75 FR 71464 - Metlife Technology, Operations, and Information Technology Groups Including On-Site Leased...

    Science.gov (United States)

    2010-11-23

    ... Employment and Training Administration Metlife Technology, Operations, and Information Technology Groups... Moosic, PA, Metlife Technology, Operations, and Information Technology Groups Including On-Site Leased... of MetLife, Technology, Operations, and Information Technology Groups, Moosic, Pennsylvania...

  4. Application for a Permit to Operate a Class III Solid Waste Disposal Site at the Nevada Test Site Area 5 Asbestiform Low-Level Solid Waste Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Programs

    2010-09-14

    -Level Waste Disposal Site in accordance with the U.S. Department of Energy, Nevada Operations Office (DOE/NV) 325, Nevada Test Site Waste Acceptance Criteria (NTSWAC, current revision). Approval will be given by NNSA/NSO to generators that have successfully demonstrated through process knowledge (PK) and/or sampling and analysis that the waste is low-level, contains asbestiform material, and does not contain prohibited waste materials. Each waste stream will be approved through the Radioactive Waste Acceptance Program (RWAP), which ensures that the waste meets acceptance requirements outlined in the NTS Class III Permit and the NTSWAC.

  5. Evaluation of Leakage Current Measurement for Site Pollution Severity Assessment

    Directory of Open Access Journals (Sweden)

    Mohammad Ali Shercat MASOUM

    2007-01-01

    Full Text Available Flashover of insulators in transmission and distribution systems may cause costly outages for power companies and their customers. Industrial and/or coastal pollution of external insulation is a major cause for such events at the normal power frequency voltage of the systems. The power companies are now facing increasing competition resulting in pressure to lower the cost and to increase the system reliability. Different methods have been applied in the past to overcome or reduce the problems with flashover on insulators. Methods which should provide reliable data under real physical conditions. In this paper several measuring methods to evaluate the pollution levels on outdoor insulators are described. According to this comparison, Leakage Current Measurement ‘LCM’ method is a reliable method for measurement leakage current in outdoor insulators and surge arresters.

  6. Site Selection of Ocean Current Power Generation from Drifter Measurements

    Science.gov (United States)

    2014-12-01

    Peter C. Chu2, Ruo-Shan Tseng3 4 5 1 Department of Marine Biotechnology and Resources, National Sun Yat-sen University, 6 Kaohsiung 80424, Taiwan...Besides 105 Kuroshio, there is a strong current with a velocity of 1.2 m s-1 in the South China Sea 106 along the coast of Vietnam. Fig. 4 shows the...more 128 than 500 m is also being developed for Kuroshio power plant near Taitung [9]. The sea 129 depth near Taitung is often more than 500 m. Thus

  7. Radiological Impact of 1993 Operations at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Simpkins, A.A.

    1994-10-28

    An offsite individual residing at the SRS boundary at the point of the maximum exposure (maximum individual) received a dose of 0.11 mrem from SRS atmospheric releases in 1993 (See Table 1 for a 5-yr history of doses). This dose was only 1.1% of the EPA public dose limit of 10 mrem/yr (DOE, 1990). Tritium oxide releases were responsible for 90% of the atmospheric dose. Ninety-nine percent of the atmospheric dose was accounted for with the inclusion of I-129, U-235, U-238, Pu-238 and Pu-239. The 50-mile population received a collective dose of 7.6 person-rem from 1993 atmospheric releases. Ninety-nine percent of this dose also resulted from the release of the same isotopes that dominated the maximum individual dose due to atmospheric releases. For both the individual and the population, atmospheric radiation dose was dominated by the inhalation and vegetation consumption pathways. The maximum dose received by an offsite individual as a result of SRS liquid releases in 1993 was 0.14 mrem (See Table 1 for a 5-yr history). This does was only 3.5% of the EPA limit for drinking water of 4 mrem/yr (DOE, 1990). This dose was dominated by Cs-137 accumulated in Savannah River fish and tritium in drinking water. More than 99% of the maximum individual dose from liquid releases resulted from tritium, Sr-90, Cs-137,and Pu-239. The population dose from liquid releases in 1993 was 1.5 person-rem. Again, tritium, Sr-90, Cs-137, and Pu-239 contributed more than 99% of this dose. The major exposure pathway to the population was drinking water. Radiation dose to the general public from operations at the Savannah River Site continued to be a very small fraction of the natural background dose. A resident of the CSRA receives about 300 mrem per year from background radiation. The population within 80 km of the SRS (620,000) and at the downstream water treatment facilities (65,000), therefore, received a natural background population dose of approximately 200,000 person-rem during 1993.

  8. Public transportation 1995: Current research in operations. Transportation research record

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    ;Contents: Metromover Extensions and Downtown Bus Service in Miami; Electric Bus Operation and Evaluation in California; Assessment of Alternative Structures for Privately Operated Bus Systems; Bus Priority at Traffic Signals in Portland: The Powell Boulevard Pilot Project; Transit Vehicle-Type Scheduling Problem; Optimal Mixed Bus Fleet for Urban Operations; Operational Characteristics of Paratransit in Developing Countries of Asia; Economics of Electric Trolley Coach Operation; Evaluation of Visual Impacts of Trolleybus Overhead Caternary System Intersections; Electric and Magnetic Fields and Electric Transit Systems; Diverting Automobile Users to Transit: Early Lessons from the Chicago Transit Authority`s Orange Line; Street-Running Rail Transit: A Historical Perspective; Diesel or Electric Power for Commuter Rail; It Depends; Generic Objectives for Evaluation of Intermodal Passenger Transfer Facilities; Airport Ground Access: Rail Transit Alternatives; Retrofit Techniques for Floating Slab Track; Calgary Light Rail Transit Surface Operations and Grade-Level Crossings; and Cost of Light Rail Collision Accidents.

  9. Current Electric Distribution Network Operation and Grid Tariffs

    DEFF Research Database (Denmark)

    Wu, Qiuwei

    2012-01-01

    The aim of EcoGridEU task 1.4 is to extend the real‐time price approach with an integrated optimization of the distribution system operation. This will be achieved by extending the basic real‐time market concept with local location‐dependant prices that reflect the grid operation, especially...

  10. 49 CFR 325.33 - Site characteristics; highway operations.

    Science.gov (United States)

    2010-10-01

    ... free of large sound-reflecting objects. However, the following objects may be within the test site... irregular tire, body, or chassis impact noise; and (2) Loose material, such as gravel or sand. (f)...

  11. Nuclear Waste Cross Site Transfer Pump Operational Resonance Resolution

    Energy Technology Data Exchange (ETDEWEB)

    HAUCK, F.M.

    1999-12-01

    Two single-volute, multi-stage centrifugal pumps are installed at a nuclear waste transfer station operated by the Department of Energy in Hanford, WA. The two parallel 100% pumps are Variable Frequency Drive operated and designed to transport waste etc.

  12. Borehole dilatometer installation, operation, and maintenance at sites in Hawaii

    Science.gov (United States)

    Myren, G.D.; Johnston, M.J.S.; Mueller, R.J.

    2006-01-01

    In response to concerns about the potential hazard of Mauna Loa volcano in Hawaii, the USGS began efforts in 1998 to add four high-resolution borehole sites. Located at these sites are; strainmeters, tiltmeters, seismometers, accelerometers and other instrumentation. These instruments are capable of providing continuous monitoring of the magma movement under Mauna Loa. Each site was planned to provide multi-parameter monitoring of volcanic activity. In June of 2000, a contract was let for the core drilling of three of these four sites. They are located at Hokukano (west side of Mauna Loa) above Captain Cook, Hawaii; at Mauna Loa Observatory (11,737 feet near the summit), and at Mauna Loa Strip Road (east side of Mauna Loa). Another site was chosen near Halema'uma u' and Kilauea's summit, in the Keller deep well. (See maps). The locations of these instruments are shown in Figure 1 with their latitude and longitude in Table 1. The purpose of this network is to monitor crustal deformation associated with volcanic intrusions and earthquakes on Mauna Loa and Kilauea volcanoes. This report describes the methods used to locate sites, install dilatometers, other instrumentation, and telemetry. We also provide a detailed description of the electronics used for signal amplification and telemetry, plus techniques used for instrument maintenance. Instrument sites were selected in regions of hard volcanic rock where the expected signals from magmatic activity were calculated to be a maximum and the probability of earthquakes with magnitude 4 or greater is large. At each location, an attempt was made to separate tectonic and volcanic signals from known noise sources for each instrument type.

  13. Electrochemical Characterization of PEMECs Operating at Various Current Densities

    DEFF Research Database (Denmark)

    Elsøe, Katrine; G.-Madsen, Laila; Scherer, Guenther G.;

    2016-01-01

    This conference contribution touches upon electrochemical characterization of operating polymer electrolyte membrane electrolysis cells (PEMECs) by the application of electrochemical impedance spectroscopy (EIS). Analysis of differences in impedance spectra (ADIS) (Jensen et al., 2007) can...

  14. 78 FR 8587 - Thomson Reuters, Finance Operations & Technology Division, Including On-Site Leased Workers From...

    Science.gov (United States)

    2013-02-06

    ... Employment and Training Administration Thomson Reuters, Finance Operations & Technology Division, Including... Worker Adjustment Assistance on August 2, 2012, applicable to workers of Thomson Reuters, Finance... that workers of Thomson Reuters, Finance Operations & Technology Division, including on-site...

  15. Hazardous Material Storage Facilities and Sites - Commercial Hazardous Waste Operations

    Data.gov (United States)

    NSGIC GIS Inventory (aka Ramona) — A Commercial Hazardous Waste Operation is a DEP primary facility type related to the Waste Management Hazardous Waste Program. The sub-facility types related to...

  16. ARM Operations and Engineering Procedure Mobile Facility Site Startup

    Energy Technology Data Exchange (ETDEWEB)

    Voyles, Jimmy W

    2015-05-01

    This procedure exists to define the key milestones, necessary steps, and process rules required to commission and operate an Atmospheric Radiation Measurement (ARM) Mobile Facility (AMF), with a specific focus toward on-time product delivery to the ARM Data Archive. The overall objective is to have the physical infrastructure, networking and communications, and instrument calibration, grooming, and alignment (CG&A) completed with data products available from the ARM Data Archive by the Operational Start Date milestone.

  17. Rocketdyne Propulsion and Power DOE operations annual site environmental report 1996

    Energy Technology Data Exchange (ETDEWEB)

    Tuttle, R.J. [ed.

    1997-11-10

    Rocketdyne currently operates several facilities in the San Fernando Valley/Simi Valley area, for manufacturing, testing, and research and development (R and D). These operations include manufacturing liquid-fueled rocket engines, such as the Space Shuttle Main Engine (SSME) and engines used for expendable launch vehicles used to place artificial satellites into orbit. This work includes fabrication and testing of rocket engines, lasers, and heat-transfer systems; and R and D in a wide range of high-technology fields, such as the electrical power system for the Space Station. Previously, this work also included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials, under the Atomics International Division (AI). AI was merged into Rocketdyne in 1984 and many of the AI functions were transferred to existing Rocketdyne departments. This nuclear work was terminated in 1988, and subsequently, all radiological work has been directed toward decontamination and decommissioning (D and D) of the previously used nuclear facilities and associated site areas. The majority of this work is done for the Department of Energy (DOE). This Annual Site Environmental Report for 1996 concentrates on the environmental conditions related to DOE operations at Area IV of SSFL and at De Soto.

  18. Radiological impact of 2016 operations at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Minter, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jannik, G. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2017-06-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2016 Savannah River Site (SRS) air and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios, such as the consumption of wildlife or goat milk.

  19. An Analysis of Current Operational Contract Support Planning Doctrine

    Science.gov (United States)

    2015-09-01

    analysis of doctrine and planning assets . The activities include interviews with various contracting and logistics professionals. F. RESEARCH...doctrine typically neglects the tangible and intangible capabilities that using OCS in missions brings to the operational and combatant commander. While... measuring the maturity of a process in practice within an organization through the issuing of surveys and measuring the responses. The model used

  20. Effect of operating current dependent series resistance on the fill factor of a solar cell

    Energy Technology Data Exchange (ETDEWEB)

    Dadu, Meena; Kapoor, A.; Tripathi, K.N. [Department of Electronic Science, University of Delhi, South Campus, Benito Juarez road, -110 021 New Delhi (India)

    2002-02-01

    The fill factor of a solar cell depends upon the series resistance, reverse saturation current, diode quality factor, operating current and voltage. Since the series resistance itself depends upon the operating current (or voltage), it makes the evaluation of fill factor very complicated. In this paper, we have evaluated the fill factor of a solar cell, taking into account operating current dependence of the series resistance.

  1. Stratification of surgical site infection by operative factors and comparison of infection rates after hernia repair.

    Science.gov (United States)

    Olsen, Margaret A; Nickel, Katelin B; Wallace, Anna E; Mines, Daniel; Fraser, Victoria J; Warren, David K

    2015-03-01

    To investigate whether operative factors are associated with risk of surgical site infection (SSI) after hernia repair. Retrospective cohort study. Patients Commercially insured enrollees aged 6 months-64 years with International Classification of Diseases, Ninth Revision, Clinical Modification procedure or Current Procedural Terminology, fourth edition, codes for inguinal/femoral, umbilical, and incisional/ventral hernia repair procedures from January 1, 2004, through December 31, 2010. SSIs within 90 days after hernia repair were identified by diagnosis codes. The χ2 and Fisher exact tests were used to compare SSI incidence by operative factors. A total of 119,973 hernia repair procedures were analyzed. The incidence of SSI differed significantly by anatomic site, with rates of 0.45% (352/77,666) for inguinal/femoral, 1.16% (288/24,917) for umbilical, and 4.11% (715/17,390) for incisional/ventral hernia repair. Within anatomic sites, the incidence of SSI was significantly higher for open versus laparoscopic inguinal/femoral (0.48% [295/61,142] vs 0.34% [57/16,524], P=.020) and incisional/ventral (4.20% [701/16,699] vs 2.03% [14/691], P=.005) hernia repairs. The rate of SSI was higher following procedures with bowel obstruction/necrosis than procedures without obstruction/necrosis for open inguinal/femoral (0.89% [48/5,422] vs 0.44% [247/55,720], P<.001) and umbilical (1.57% [131/8,355] vs 0.95% [157/16,562], P<.001), but not incisional/ventral hernia repair (4.01% [224/5,585] vs 4.16% [491/11,805], P=.645). The incidence of SSI was highest after open procedures, incisional/ventral repairs, and hernia repairs with bowel obstruction/necrosis. Stratification of hernia repair SSI rates by some operative factors may facilitate accurate comparison of SSI rates between facilities.

  2. DISSS/PSDB - Personnel Security Database Modernization Project: Compilation of data gathered from DOE Operations Office`s site visits

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, R.; Sweeney, D.

    1995-03-15

    This document is a compilation of the information gathered from visits to the DOE Operations Offices. The purpose of these visits was to gather requirements for the modernization of the personnel security database. The initial phase of visits were to sites which had known local systems to augment CPCI. They were; Rocky Flats, Richland, Las Vegas, Savannah River, Oak Ridge, and Oakland. The second phase of site visits were to; Headquarters, Schenectady, Pittsburgh, Idaho Falls, Chicago, and Albuquerque. We also visited the NRC. At each site we reviewed the current clearance process in use at the field office. If the site had a local personnel security database (PSDB), we also reviewed the current PSDB processing. Each meeting was began with the a discussion on the purpose of the meeting and the background of the redesign effort.

  3. Inventory of managed aquifer recharge sites in Europe: historical development, current situation and perspectives

    Science.gov (United States)

    Sprenger, C.; Hartog, N.; Hernández, M.; Vilanova, E.; Grützmacher, G.; Scheibler, F.; Hannappel, S.

    2017-03-01

    Different types of managed aquifer recharge (MAR) schemes are widely distributed and applied on various scales and for various purposes in the European countries, but a systematic categorization and compilation of data has been missing up to now. The European MAR catalogue presented herein contains various key parameters collected from the available literature. The catalogue includes 224 currently active MAR sites found in 23 European countries. Large quantities of drinking water are produced by MAR sites in Hungary, Slovakia, the Netherlands, Germany, Finland, Poland, Switzerland and France. This inventory highlights that, for over a century, MAR has played an important role in the development of European water supply and contributes to drinking-water production substantially. This development has occurred autonomously, with "trial-and-error" within the full range of climatically and hydrogeologically diverse conditions of the European countries. For the future, MAR has the potential to facilitate optimal (re)use and storage of available water resources and to take advantage of the natural purification and low energy requirements during MAR operations. Particularly with respect to the re-use of wastewater treatment-plant effluent and stormwater, which is currently underdeveloped, the use of MAR can support the public acceptance of such water-resource efficient schemes. Particularly for the highly productive and urbanized coastal zones, where the pressure on freshwater supplies increases by growing water demand, salinization and increased agricultural needs for food production (such as along the Mediterranean and North Sea coasts), MAR is expected to be increasingly relied on in Europe.

  4. Inventory of managed aquifer recharge sites in Europe: historical development, current situation and perspectives

    Science.gov (United States)

    Sprenger, C.; Hartog, N.; Hernández, M.; Vilanova, E.; Grützmacher, G.; Scheibler, F.; Hannappel, S.

    2017-09-01

    Different types of managed aquifer recharge (MAR) schemes are widely distributed and applied on various scales and for various purposes in the European countries, but a systematic categorization and compilation of data has been missing up to now. The European MAR catalogue presented herein contains various key parameters collected from the available literature. The catalogue includes 224 currently active MAR sites found in 23 European countries. Large quantities of drinking water are produced by MAR sites in Hungary, Slovakia, the Netherlands, Germany, Finland, Poland, Switzerland and France. This inventory highlights that, for over a century, MAR has played an important role in the development of European water supply and contributes to drinking-water production substantially. This development has occurred autonomously, with "trial-and-error" within the full range of climatically and hydrogeologically diverse conditions of the European countries. For the future, MAR has the potential to facilitate optimal (re)use and storage of available water resources and to take advantage of the natural purification and low energy requirements during MAR operations. Particularly with respect to the re-use of wastewater treatment-plant effluent and stormwater, which is currently underdeveloped, the use of MAR can support the public acceptance of such water-resource efficient schemes. Particularly for the highly productive and urbanized coastal zones, where the pressure on freshwater supplies increases by growing water demand, salinization and increased agricultural needs for food production (such as along the Mediterranean and North Sea coasts), MAR is expected to be increasingly relied on in Europe.

  5. Tumescent mastectomy: the current indications and operative tips and tricks

    Directory of Open Access Journals (Sweden)

    Khater A

    2017-03-01

    Full Text Available Ashraf Khater,1 Alaa Mazy,2 Mona Gad,2 Ola Taha Abd Eldayem,2 Mohamed Hegazy1 1Department of Surgical Oncology, Mansoura Oncology Center (OCMU, 2Anesthesia and Surgical Intensive Care Department, Mansoura University Hospital, Faculty of Medicine, Mansoura University, Mansoura, Egypt Background: Tumescent mastectomy refers to usage of a mixture of lidocaine and epinephrine in a diluting saline solution that makes flaps firm and tense, thus minimizing systemic drugs toxicity and making surgery possible with minimal bleeding. This technique is very useful in elder women and those with American Society of Anesthesiologists; score III and IV. The objective was to establish an alternative safe technique to general anesthesia in some selected mastectomy patients.Patients and methods: Twenty candidate women for total mastectomy and axillary dissection were enrolled and consented to participate. After preparation, an anatomically directed infiltration was made under sedation, using a cocktail of lidocaine, bupivacaine, and epinephrine, followed after 20 minutes by the surgical incision and completion of mastectomy. All intraoperative and postoperative outcomes were recorded.Results: Although 7 cases required added analgesic medications, no conversion for general anesthesia was recorded. Mean operative time was 81±15.8 minutes. Mean blood loss was 95.8±47.5 mL. There was no recorded intraoperative hemodynamic instability. Postoperative visual analog score was not exceeding 4 till the end of the first 24 hours. Opioids were not required in any case, and the mean dosage of Ketorolac used was 30±8.75 mg. Drains output and the incidence of postoperative complications were acceptable.Conclusion: We can consider tumescent mastectomy in well-selected patients a safe alternative for performing mastectomy when general anesthesia is hazardous, with minimal blood loss and long lasting postoperative analgesia without an additive effect on the operative time

  6. Tumescent mastectomy: the current indications and operative tips and tricks

    Science.gov (United States)

    Khater, Ashraf; Mazy, Alaa; Gad, Mona; Taha Abd Eldayem, Ola; Hegazy, Mohamed

    2017-01-01

    Background Tumescent mastectomy refers to usage of a mixture of lidocaine and epinephrine in a diluting saline solution that makes flaps firm and tense, thus minimizing systemic drugs toxicity and making surgery possible with minimal bleeding. This technique is very useful in elder women and those with American Society of Anesthesiologists; score III and IV. The objective was to establish an alternative safe technique to general anesthesia in some selected mastectomy patients. Patients and methods Twenty candidate women for total mastectomy and axillary dissection were enrolled and consented to participate. After preparation, an anatomically directed infiltration was made under sedation, using a cocktail of lidocaine, bupivacaine, and epinephrine, followed after 20 minutes by the surgical incision and completion of mastectomy. All intraoperative and postoperative outcomes were recorded. Results Although 7 cases required added analgesic medications, no conversion for general anesthesia was recorded. Mean operative time was 81±15.8 minutes. Mean blood loss was 95.8±47.5 mL. There was no recorded intraoperative hemodynamic instability. Postoperative visual analog score was not exceeding 4 till the end of the first 24 hours. Opioids were not required in any case, and the mean dosage of Ketorolac used was 30±8.75 mg. Drains output and the incidence of postoperative complications were acceptable. Conclusion We can consider tumescent mastectomy in well-selected patients a safe alternative for performing mastectomy when general anesthesia is hazardous, with minimal blood loss and long lasting postoperative analgesia without an additive effect on the operative time, hospital stay, and intraoperative and postoperative complications. PMID:28408853

  7. Characteristics of operations at fish-landing sites managed by private owners in Thailand

    OpenAIRE

    Yoshimura, Mika; Okamoto, Junichiro; Yasuma, Hiroki; Kimura, Nobuo

    2016-01-01

    This study presents the results of a survey on the operation characteristics of landing sites managed by private owners in Thailand. The survey was conducted by interviewing private landing site owners, managers of fishery cooperatives, middlemen, and fishers. The results of interviews were summarized with respect to scale of business, fisheries, transaction, types of people associated with landing sites, location, and daily schedule. Landing sites were located along canals in coastal provinc...

  8. Installation and Operation of the SNO Neutral Current Detector Array

    Science.gov (United States)

    SNO Collaboration; McGee, S.; Rielage, K.

    2005-06-01

    An array of low background detectors designed to capture neutrons liberated by interactions with solar neutrinos was recently installed in the heavy water region of the SNO experiment. The neutral current detector (NCD) array consists of 36 proportional counters filled with 3He-CF4 gas and 4 proportional counters filled with 4He-CF4. Special hardware conforming to the high radiopurity requirements in SNO was used to assemble and deploy these counters. Neutron events detected by the NCD array are distinguished from various types of backgrounds on an event-by-event basis using the NCD data acquisition system (NCDDAQ), which employs a mixture of commercial and custom-built electronics equipment. The NCDDAQ is controlled by a custom-built Object-oriented Realtime Control and Acquisition (ORCA) software program, and is fully integrated into the SNO PMT data acquisition system to provide shared trigger information and a combined data stream.

  9. Installation and Operation of the SNO Neutral Current Detector Array

    Energy Technology Data Exchange (ETDEWEB)

    Heise, J. [Physics Division, Los Alamos National Laboratory, Los Alamos, NM, 87545 (United States); McGee, S. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA, 98195 (United States); Rielage, K. [Center for Experimental Nuclear Physics and Astrophysics, and Department of Physics, University of Washington, Seattle, WA, 98195 (United States)

    2005-06-15

    An array of low background detectors designed to capture neutrons liberated by interactions with solar neutrinos was recently installed in the heavy water region of the SNO experiment. The neutral current detector (NCD) array consists of 36 proportional counters filled with {sup 3}He-CF{sub 4} gas and 4 proportional counters filled with {sup 4}He-CF{sub 4}. Special hardware conforming to the high radiopurity requirements in SNO was used to assemble and deploy these counters. Neutron events detected by the NCD array are distinguished from various types of backgrounds on an event-by-event basis using the NCD data acquisition system (NCDDAQ), which employs a mixture of commercial and custom-built electronics equipment. The NCDDAQ is controlled by a custom-built Object-oriented Realtime Control and Acquisition (ORCA) software program, and is fully integrated into the SNO PMT data acquisition system to provide shared trigger information and a combined data stream.

  10. Operational advances in ring current modeling using RAM-SCB

    Energy Technology Data Exchange (ETDEWEB)

    Welling, Daniel T [Los Alamos National Laboratory; Jordanova, Vania K [Los Alamos National Laboratory; Zaharia, Sorin G [Los Alamos National Laboratory; Morley, Steven K [Los Alamos National Laboratory

    2010-12-03

    The Ring current Atmosphere interaction Model with Self-Consistently calculated 3D Magnetic field (RAM-SCB) combines a kinetic model of the ring current with a force-balanced model of the magnetospheric magnetic field to create an inner magnetospheric model that is magnetically self consistent. RAM-SCB produces a wealth of outputs that are valuable to space weather applications. For example, the anisotropic particle distribution of the KeV-energy population calculated by the code is key for predicting surface charging on spacecraft. Furthermore, radiation belt codes stand to benefit substantially from RAM-SCB calculated magnetic field values and plasma wave growth rates - both important for determining the evolution of relativistic electron populations. RAM-SCB is undergoing development to bring these benefits to the space weather community. Data-model validation efforts are underway to assess the performance of the system. 'Virtual Satellite' capability has been added to yield satellite-specific particle distribution and magnetic field output. The code's outer boundary is being expanded to 10 Earth Radii to encompass previously neglected geosynchronous orbits and allow the code to be driven completely by either empirical or first-principles based inputs. These advances are culminating towards a new, real-time version of the code, rtRAM-SCB, that can monitor the inner magnetosphere conditions on both a global and spacecraft-specific level. This paper summarizes these new features as well as the benefits they provide the space weather community.

  11. [Evoked potentials in intracranial operations: current status and our experiences].

    Science.gov (United States)

    Nau, H E; Hess, W; Pohlen, G; Marggraf, G; Rimpel, J

    1987-03-01

    Intraoperative neuromonitoring, especially evoked potential monitoring, has gained interest in recent years for both the anesthesiologist evaluating cerebral function and the neurosurgeon wishing to avoid neuronal lesions during intracranial operations. Before evoked potential monitoring can be introduced as a routine method of intraoperative management, experience with this method particularly in intensive care units, is imperative. We recorded evoked potentials with the Compact Four (Nicolet) and Basis 8000 (Schwarzer Picker International) computer systems. Preoperative derivations should be done with the same apparatus used intraoperatively and parameters of peri- and intraoperative derivations should not be changed. The patient's head must be fixed in a Mayfield clamp in order to avoid artefacts during trepanation. The possible artefacts due to apparatus, patient, or anesthesia are summarized in the tables. The derivations of evoked potentials should be supervised by a person who is not involved in the anesthesia or the surgical procedure; this condition may change in the future with full automatization of the recording technique and alarms. Good communication between surgeon, anesthesiologist, and neurophysiological assistant is a prerequisite. The modality is chosen in accordance with the affected neuronal system: visual-evoked potential (VEP) monitoring in the management of processes affecting the visual pathway, brain stem auditory-(BAER) and somatosensory-evoked potential (SSEP) monitoring in lesions affecting these pathways, in particular space-occupying lesions of the posterior fossa. VEP monitoring may be useful, but we observed alterations of the responses without changes in the level of anesthesia or manipulation of the visual pathways. In space-occupying processes of the cerebellopontine angle, BAER could not be developed in nearly all cases because the large underlying tumor had caused the disappearance of waves II-V. In these cases SSEP monitoring

  12. DAG telescope site studies and infrastructure for possible international co-operations

    Science.gov (United States)

    Yerli, Sinan K.; Yeşilyaprak, Cahit; Keskin, Onur; Alis, Sinan

    2016-07-01

    The selected site for the 4 m DAG (Eastern Anatolian Observatory in Turkish) telescope is at "Karakaya Ridge", at 3170 m altitude (3150 m after summit management). The telescope's optical design is performed by the DAG technical team to allow infrared observation at high angular resolution, with its adaptive optics system to be built in Turkey. In this paper; a brief introduction about DAG telescope design; planned instrumentation; the meteorological data collected from 2008, clear night counts, short-term DIMM observations; current infrastructure to hold auxiliary telescopes; auxiliary buildings to assist operations; the observatory design; and coating unit plans will be presented along with possible collaboration possibilities in terms of instrumentation and science programs.

  13. Edge Currents and Vertex Operators for Chern-Simons Gravity

    CERN Document Server

    Bimonte, G; Stern, A

    1993-01-01

    We apply elementary canonical methods for the quantization of 2+1 dimensional gravity, where the dynamics is given by E. Witten's $ISO(2,1)$ Chern-Simons action. As in a previous work, our approach does not involve choice of gauge or clever manipulations of functional integrals. Instead, we just require the Gauss law constraint for gravity to be first class and also to be everywhere differentiable. When the spatial slice is a disc, the gravitational fields can either be unconstrained or constrained at the boundary of the disc. The unconstrained fields correspond to edge currents which carry a representation of the $ISO(2,1)$ Kac-Moody algebra. Unitary representations for such an algebra have been found using the method of induced representations. In the case of constrained fields, we can classify all possible boundary conditions. For several different boundary conditions, the field content of the theory reduces precisely to that of 1+1 dimensional gravity theories. We extend the above formalism to include sou...

  14. Zeros and poles of quantum current operators and the condition of quantum integrability

    CERN Document Server

    Ding, J; Ding, Jintai; Miwa, Tetsuji

    1996-01-01

    For the current realization of the affine quantum groups, a simple comultiplication for the quantum current operators was given by Drinfeld. With this comultiplication, we study the zeros and poles of the quantum current operators and present a condition of integrability on the quantum current of $U_q\\left(\\hat{\\frak sl}(2)\\right)$, which is a deformation of the corresponding condition for $\\hat{\\frak sl}(2)$.

  15. Summary of operations and performance of the Murdock site restoration project in 2008.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2009-06-04

    This document summarizes the performance of the groundwater and surface water restoration systems installed by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) at the former CCC/USDA grain storage facility in Murdock, Nebraska, during the third full year of system operation, from January 1 through December 31, 2008. Performance in June 2005 through December 2007 was reported previously (Argonne 2007, 2008). In the Murdock project, several innovative technologies are being used to remove carbon tetrachloride contamination from a shallow aquifer underlying the town, as well as from water naturally discharged to the surface at the headwaters of a small creek (a tributary to Pawnee Creek) north of the town (Figure 1.1). The restoration activities at Murdock are being conducted by the CCC/USDA as a non-time-critical removal action under the regulatory authority and supervision of the U.S. Environmental Protection Agency (EPA), Region VII. Argonne National Laboratory assisted the CCC/USDA by providing technical oversight for the restoration effort and facilities during this review period. Included in this report are the results of all sampling and monitoring activities performed in accord with the EPA-approved Monitoring Plan for this site (Argonne 2006), as well as additional investigative activities conducted during the review period. The annual performance reports for the Murdock project assemble information that will become part of the five-year review and evaluation of the remediation effort. This review will occur in 2010. This document presents overviews of the treatment facilities (Section 2) and site operations and activities (Section 3), then describes the groundwater, surface water, vegetation, and atmospheric monitoring results (Section 4) and modifications and costs during the review period (Section 5). Section 6 summarizes the current period of operation. A gallery of photographs of the Murdock project is in Appendix A.

  16. Nuclear Operations Application to Environmental Restoration at Corrective Action Unit 547, Miscellaneous Contaminated Waste Sites, at the Nevada National Security Site

    Energy Technology Data Exchange (ETDEWEB)

    Kevin Cabble (NSO), Mark Krauss and Patrick Matthews (N-I)

    2011-03-03

    The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office has responsibility for environmental restoration at the Nevada National Security Site (formerly the Nevada Test Site). This includes remediation at locations where past testing activities have resulted in the release of plutonium to the environment. One of the current remediation efforts involves a site where an underground subcritical nuclear safety test was conducted in 1964. The underground test was vented through a steel pipe to the surface in a closed system where gas samples were obtained. The piping downstream of the gas-sampling apparatus was routed belowground to a location where it was allowed to vent into an existing radioactively contaminated borehole. The length of the pipe above the ground surface is approximately 200 meters. This pipe remained in place until remediation efforts began in 2007, at which time internal plutonium contamination was discovered. Following this discovery, an assessment was conducted to determine the quantity of plutonium present in the pipe. This site has been identified as Corrective Action Unit (CAU) 547, Miscellaneous Contaminated Waste Sites. The quantity of plutonium identified at CAU 547 exceeded the Hazard Category 3 threshold but was below the Hazard Category 2 threshold specified in DOE Standard DOE-STD-1027-92. This CAU, therefore, was initially categorized as a Hazard Category 3 environmental restoration site. A contaminated facility or site that is initially categorized as Hazard Category 3, however, may be downgraded to below Hazard Category 3 if it can be demonstrated through further analysis that the form of the material and the energy available for release support reducing the hazard category. This is an important consideration when performing hazard categorization of environmental restoration sites because energy sources available for release of material are generally fewer at an environmental restoration site

  17. Village operator feasibility framework: A recommended method for assessing the viability of village operator sites

    CSIR Research Space (South Africa)

    Von Staden, R

    2009-10-01

    Full Text Available their viability. This framework proposes that feasibility is assessed according to six dimensions – Operational, Market, Technical, Social, Management and Financial Feasibility. A theoretical overview is provided for each dimension, along with some practical...

  18. Application for Permit to Operate a Class III Solid Waste Disposal Site at the Nevada Test Site - U10c Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Programs

    2010-08-05

    The NTS is located approximately 105 km (65 mi) northwest of Las Vegas, Nevada. NNSA/NSO is the federal lands management authority for the NTS and NSTec is the Management & Operations contractor. Access on and off the NTS is tightly controlled, restricted, and guarded on a 24-hour basis. The NTS is posted with signs along its entire perimeter. NSTec is the operator of all solid waste disposal sites on the NTS. The U10C Disposal Site is located in the northwest corner of Area 9 at the NTS (Figure 1) and is located in a subsidence crater created by two underground nuclear events, one in October 1962 and another in April 1964. The disposal site opened in 1971 for the disposal of rubbish, refuse, pathological waste, asbestos-containing material, and industrial solid waste. A Notice of Intent form to operate the disposal site as a Class II site was submitted to the state of Nevada on January 26, 1994, and was acknowledged in a letter to the DOE on February 8, 1994. It operated as a state of Nevada Class II Solid Waste Disposal Site (SWDS) until it closed on October 5, 1995, for retrofit as a Class III SWDS. The retrofit consisted of the installation of a minimum four-foot compacted soil layer to segregate the different waste types and function as a liner to inhibit leachate and water flow into the lower waste zone. Five neutron monitoring tubes were installed in this layer to monitor possible leachate production and water activity. Upon acceptance of the installed barrier and approval of an Operating Plan by NDEP/BFF, the site reopened in January 1996 as a Class III SWDS for the disposal of industrial solid waste and other inert waste.

  19. Nuclear axial current operators to fourth order in chiral effective field theory

    CERN Document Server

    Krebs, H; Meißner, U -G

    2016-01-01

    We present the complete derivation of the nuclear axial charge and current operators as well as the pseudoscalar operators to fourth order in the chiral expansion relative to the dominant one-body contribution using the method of unitary transformation. We demonstrate that the unitary ambiguity in the resulting operators can be eliminated by the requirement of renormalizability and by matching of the pion-pole contributions to the nuclear forces. We give expressions for the renormalized single-, two- and three-nucleon contributions to the charge and current operators and pseudoscalar operators including the relevant relativistic corrections. We also verify explicitly the validity of the continuity equation.

  20. Lessons learned from an installation perspective for chemical demilitarization plant start-up at four operating incineration sites.

    Energy Technology Data Exchange (ETDEWEB)

    Motz, L.; Decision and Information Sciences

    2011-02-21

    This study presents the lessons learned by chemical storage installations as they prepared for the start of chemical demilitarization plant operations at the four current chemical incinerator sites in Alabama, Arkansas, Oregon, and Utah. The study included interviews with persons associated with the process and collection of available documents prepared at each site. The goal was to provide useful information for the chemical weapons storage sites in Colorado and Kentucky that will be going through plant start-up in the next few years. The study is not a compendium of what to do and what not to do. The information has been categorized into ten lessons learned; each is discussed individually. Documents that may be useful to the Colorado and Kentucky sites are included in the appendices. This study should be used as a basis for planning and training.

  1. Crystallization In High Level Waste (HLW) Glass Melters: Operational Experience From The Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M.

    2014-02-27

    processing strategy for the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The basis of this alternative approach is an empirical model predicting the crystal accumulation in the WTP glass discharge riser and melter bottom as a function of glass composition, time, and temperature. When coupled with an associated operating limit (e.g., the maximum tolerable thickness of an accumulated layer of crystals), this model could then be integrated into the process control algorithms to formulate crystal tolerant high level waste (HLW) glasses targeting higher waste loadings while still meeting process related limits and melter lifetime expectancies. This report provides a review of the scaled melter testing that was completed in support of the Defense Waste Processing Facility (DWPF) melter. Testing with scaled melters provided the data to define the DWPF operating limits to avoid bulk (volume) crystallization in the un-agitated DWPF melter and provided the data to distinguish between spinels generated by K-3 refractory corrosion versus spinels that precipitated from the HLW glass melt pool. This report includes a review of the crystallization observed with the scaled melters and the full scale DWPF melters (DWPF Melter 1 and DWPF Melter 2). Examples of actual DWPF melter attainment with Melter 2 are given. The intent is to provide an overview of lessons learned, including some example data, that can be used to advance the development and implementation of an empirical model and operating limit for crystal accumulation for WTP. Operation of the first and second (current) DWPF melters has demonstrated that the strategy of using a liquidus temperature predictive model combined with a 100 °C offset from the normal melter operating temperature of 1150 °C (i.e., the predicted liquidus temperature (TL) of the glass must be 1050 °C or less) has been successful in preventing any detrimental accumulation of spinel in the DWPF melt pool, and spinel has not been

  2. Electric and Hybrid Vehicle Program, Site Operator Program. Quarterly progress report for July through September 1994 (Fourth quarter of fiscal year 1994)

    Energy Technology Data Exchange (ETDEWEB)

    Kiser, D.M.; Brown, H.L.

    1995-03-01

    The Site Operator Program was initially established by the Department of Energy (DOE) to incorporate the electric vehicle activities dictated by the Electric and Hybrid Vehicle Research, Development and Demonstration Act of 1976. In the ensuing years, the Program has evolved in response to new legislation and interests. The Program currently includes twelve sites located in diverse geographic, metrologic, and metropolitan areas across the US. Information is shared reciprocally with a thirteenth site, not under Program contract. The vehicles are operator-owned, except for two Griffon vans. The Mission Statement of the Site Operator Program includes three major activities: advancement of electric vehicle technologies; development of infrastructure elements necessary to support significant electric vehicle use; and increasing the awareness and acceptance of electric vehicles (EVs) by the public. The current participants in the Site Operator Program are shown. The ultimate thrust of program activities varies among sites, reflecting not only the Operator`s business interests but also geographic and climate-related operating conditions. This fourth quarter report (FY-94) includes a summary of activities from the previous three quarters. The report section sequence has been revised to provide a more easily seen program overview, and specific operator activities are now found in Appendix A.

  3. Uncertainty analysis of the Operational Simplified Surface Energy Balance (SSEBop) model at multiple flux tower sites

    Science.gov (United States)

    Chen, Mingshi; Senay, Gabriel B.; Singh, Ramesh K.; Verdin, James P.

    2016-01-01

    Evapotranspiration (ET) is an important component of the water cycle – ET from the land surface returns approximately 60% of the global precipitation back to the atmosphere. ET also plays an important role in energy transport among the biosphere, atmosphere, and hydrosphere. Current regional to global and daily to annual ET estimation relies mainly on surface energy balance (SEB) ET models or statistical and empirical methods driven by remote sensing data and various climatological databases. These models have uncertainties due to inevitable input errors, poorly defined parameters, and inadequate model structures. The eddy covariance measurements on water, energy, and carbon fluxes at the AmeriFlux tower sites provide an opportunity to assess the ET modeling uncertainties. In this study, we focused on uncertainty analysis of the Operational Simplified Surface Energy Balance (SSEBop) model for ET estimation at multiple AmeriFlux tower sites with diverse land cover characteristics and climatic conditions. The 8-day composite 1-km MODerate resolution Imaging Spectroradiometer (MODIS) land surface temperature (LST) was used as input land surface temperature for the SSEBop algorithms. The other input data were taken from the AmeriFlux database. Results of statistical analysis indicated that the SSEBop model performed well in estimating ET with an R2 of 0.86 between estimated ET and eddy covariance measurements at 42 AmeriFlux tower sites during 2001–2007. It was encouraging to see that the best performance was observed for croplands, where R2 was 0.92 with a root mean square error of 13 mm/month. The uncertainties or random errors from input variables and parameters of the SSEBop model led to monthly ET estimates with relative errors less than 20% across multiple flux tower sites distributed across different biomes. This uncertainty of the SSEBop model lies within the error range of other SEB models, suggesting systematic error or bias of the SSEBop model is within

  4. Uncertainty analysis of the Operational Simplified Surface Energy Balance (SSEBop) model at multiple flux tower sites

    Science.gov (United States)

    Chen, Mingshi; Senay, Gabriel B.; Singh, Ramesh K.; Verdin, James P.

    2016-05-01

    Evapotranspiration (ET) is an important component of the water cycle - ET from the land surface returns approximately 60% of the global precipitation back to the atmosphere. ET also plays an important role in energy transport among the biosphere, atmosphere, and hydrosphere. Current regional to global and daily to annual ET estimation relies mainly on surface energy balance (SEB) ET models or statistical and empirical methods driven by remote sensing data and various climatological databases. These models have uncertainties due to inevitable input errors, poorly defined parameters, and inadequate model structures. The eddy covariance measurements on water, energy, and carbon fluxes at the AmeriFlux tower sites provide an opportunity to assess the ET modeling uncertainties. In this study, we focused on uncertainty analysis of the Operational Simplified Surface Energy Balance (SSEBop) model for ET estimation at multiple AmeriFlux tower sites with diverse land cover characteristics and climatic conditions. The 8-day composite 1-km MODerate resolution Imaging Spectroradiometer (MODIS) land surface temperature (LST) was used as input land surface temperature for the SSEBop algorithms. The other input data were taken from the AmeriFlux database. Results of statistical analysis indicated that the SSEBop model performed well in estimating ET with an R2 of 0.86 between estimated ET and eddy covariance measurements at 42 AmeriFlux tower sites during 2001-2007. It was encouraging to see that the best performance was observed for croplands, where R2 was 0.92 with a root mean square error of 13 mm/month. The uncertainties or random errors from input variables and parameters of the SSEBop model led to monthly ET estimates with relative errors less than 20% across multiple flux tower sites distributed across different biomes. This uncertainty of the SSEBop model lies within the error range of other SEB models, suggesting systematic error or bias of the SSEBop model is within the

  5. Robotic laparoendoscopic single-site surgery(R-LESS):current status in urology%Robotic laparoendoscopic single-site surgery(R-LESS) :current status in urology

    Institute of Scientific and Technical Information of China (English)

    Riccardo Autorino; YANG Bo; Jihad H. Kaouk

    2011-01-01

    Laparoendoscopic single-site surgery (LESS) is technically challenging; it can reduces instrument triangulation and robust retraction and is associated with a steep learning curve.The instruments of the daVinci(R) surgical system (Intuitive Surgical) are designed with seven degrees of motion mimicing the dexterity of the human hand and wrist.This inherent feature of the robotic arm provides superior ergonomics when performing LESS,especially for complex reconstructive surgery.This review analyzes the evidence supporting current and future application of robotic technology in the field of urologic LESS.

  6. Characterization ReportOperational Closure Covers for the Area 5 Radioactive Waste Management Site at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Bechtel Nevada Geotechnical Sciences

    2005-06-01

    Bechtel Nevada (BN) manages two low-level Radioactive Waste Management Sites (RWMSs) at the Nevada Test Site (NTS) for the U.S. Department of Energy (DOE) National Nuclear Security Administration Nevada Site Office (NNSA/NSO). The Area 3 RWMS is located in south-central Yucca Flat and the Area 5 RWMS is located about 15 miles south, in north-central Frenchman Flat. Though located in two separate topographically closed basins, they are similar in climate and hydrogeologic setting. The Area 5 RWMS uses engineered shallow-land burial cells to dispose of packaged waste, while the Area 3 RWMS uses subsidence craters formed from underground testing of nuclear weapons for the disposal of packaged and unpackaged bulk waste. Over the next several decades, most waste disposal units at both the Area 3 and Area 5 RWMSs are anticipated to be closed. Closure of the Area 3 and Area 5 RWMSs will proceed through three phases: operational closure, final closure, and institutional control. Many waste disposal units at the Area 5RWMS are operationally closed and final closure has been placed on one unit at the Area 3 RWMS (U-3ax/bl). Because of the similarities between the two sites (e.g., type of wastes, environmental factors, operational closure cover designs, etc.), many characterization studies and data collected at the Area 3 RWMS are relevant and applicable to the Area 5 RWMS. For this reason, data and closure strategies from the Area 3 RWMS are referred to as applicable. This document is an interim Characterization Report – Operational Closure Covers, for the Area 5 RWMS. The report briefly describes the Area 5 RWMS and the physical environment where it is located, identifies the regulatory requirements, reviews the approach and schedule for closing, summarizes the monitoring programs, summarizes characterization studies and results, and then presents conclusions and recommendations.

  7. Simulation of non-Abelian anyons using ribbon operators connected to a common base site

    Energy Technology Data Exchange (ETDEWEB)

    Luo Xiwang; Han Yongjian; Guo Guangcan; Zhou Xingxiang; Zhou Zhengwei [Key Laboratory of Quantum Information, University of Science and Technology of China, Hefei, Anhui 230026 (China)

    2011-11-15

    A convenient and effective way in the quantum double model to study anyons in a topological space with a tensor product structure is to create and braid anyons using ribbon operators connected to a common base site [A. Kitaev, Ann. Phys. (NY) 303, 2 (2003)]. We show how this scheme can be simulated in a physical system by constructing long ribbon operators connected to a base site that is placed far away. We describe how to move and braid anyons using these ribbon operators, and how to perform measurement on them. We also give the smallest scale of a system that is sufficient for proof-of-principle demonstration of our scheme.

  8. Analysis of potential impacts of Flaming Gorge Dam hydropower operations on archaeological sites

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, K.L.; Malinowski, L.M.; Hoffecker, J.F.

    1955-12-01

    An archaeological field study was conducted along the Green River in the areas of Little Hole and Browns Park in Utah and Colorado. The purpose of the study was to measure the potential for hydropower operations at Flaming Gorge Dam to directly or indirectly affect archaeological sites in the study area. Thirty-four known sites were relocated, and six new sites were recorded. Information was collected at each site regarding location, description, geomorphic setting, sedimentary context, vegetation, slope, distance from river, elevation above river level, and site condition. Matching the hydrologic projections of river level and sediment load with the geomorphic and sedimentary context at specific site locations indicated that eight sites were in areas with a high potential for erosion.

  9. A grid side converter current controller for accurate current injection under normal and fault ride through operation

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Blaabjerg, Frede

    2013-01-01

    requirements. In addition, the renewable energy systems require fault ride through capability in order to support the power grid under balanced or unbalanced low voltage grid faults. Therefore, the development of advanced current controller techniques is essential for the grid side power electronic converters...... in order to increase the renewable energy systems penetration and satisfy the grid codes. This paper proposes a current controller technique, which enables the appropriate operation of the grid side converter under unbalanced grid faults and harmonic distorted grid conditions. The proposed current......Modern grid codes for interconnection of distributed energy resources have become more restrictive due to the massive integration of renewable energy sources. The interconnected renewable energy sources must operate accurately under normal and abnormal grid conditions in order to meet the grid...

  10. Direct-current resistivity data from 94 sites in northeastern Palm Beach County, Florida

    Science.gov (United States)

    Peterson, Cathleen J.

    1988-01-01

    Direct-current resistivity data were collected from 94 vertical electric sounding profiles in northeastern Palm Beach County, Florida. Direct-current resistivity data, which may be used to determine the location and thicknesses of shallow, semipermeable marls or locate zones of high chloride concentration, are presented in this report. The resistivity data consist of field data, smoothed data, layer resistivity from smoothed data, and Cartesian graphs of resistivity in relation to depth for 94 sites located in northeastern Palm Beach County. (USGS)

  11. A high-speed CMOS current op amp for very low supply voltage operation

    DEFF Research Database (Denmark)

    Bruun, Erik

    1994-01-01

    A CMOS implementation of a high-gain current mode operational amplifier (op amp) with a single-ended input and a differential output is described. This configuration is the current mode counterpart of the traditional voltage mode op amp. In order to exploit the inherent potential for high speed......, low voltage operation normally associated with current mode analog signal processing, the op amp has been designed to operate off a supply voltage of 1.5 V, and the signal path has been confined to N-channel transistors. With this design, a gain of 94 dB and a gain-bandwidth product of 65 MHz has been...

  12. Site Environmental Report for Calendar Year 1999. DOE Operations at The Boeing Company, Rocketdyne

    Energy Technology Data Exchange (ETDEWEB)

    None

    2000-09-01

    OAK A271 Site Environmental Report for Calendar Year 1999. DOE Operations at The Boeing Company, Rocketdyne. This Annual Site Environmental Report (ASER) for 1999 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Rocketdyne Santa Susana Field Laboratory (SSFL). In the past, these operations included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials under the former Atomics International Division. Other activities included the operation of large-scale liquid metal facilities for testing of liquid metal fast breeder components at the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility within Area IV. All nuclear work was terminated in 1988, and subsequently, all radiological work has been directed toward decontamination and decommissioning (D&D) of the previously used nuclear facilities and associated site areas. Large-scale D&D activities of the sodium test facilities began in 1996. This Annual Site Environmental Report provides information showing that there are no indications of any potential impact on public health and safety due to the operations conducted at the SSFL. All measures and calculations of off-site conditions demonstrate compliance with applicable regulations, which provide for protection of human health and the environment.

  13. BIOTIC INTEGRITY OF STREAMS IN THE SAVANNAH RIVER SITE INTEGRATOR OPERABLE UNITS, 1996 TO 2003

    Energy Technology Data Exchange (ETDEWEB)

    Paller, M; Susan Dyer, S

    2004-11-08

    The Savannah River Site (SRS) has been divided into six Integrator Operable Units (IOUs) that correspond to the watersheds of the five major streams on the SRS (Upper Three Runs, Fourmile Branch, Pen Branch, Steel Creek, and Lower Three Runs) and the portions of the Savannah River and Savannah River Swamp associated with the SRS. The streams are the primary integrators within each IOU because they potentially receive, through surface or subsurface drainage, soluble contaminants from all waste sites within their watersheds. If these contaminants reach biologically significant levels, they would be expected to effect the numbers, types, and health of stream organisms. In this study, biological sampling was conducted within each IOU as a measure of the cumulative ecological effects of the waste sites within the IOUs. The use of information from biological sampling to assess environmental quality is often termed bioassessment. The IOU bioassessment program included 38 sites in SRS streams and nine sites in the Savannah River. Sampling was conducted in 1996 to 1998, 2000, and 2003. Four bioassessment methods were used to evaluate ecological conditions in the IOU streams: the Index of Biotic Integrity, the Fish Health Assessment Index, measurement of fish tissue contaminant levels, and two benthic macroinvertebrate indices. The Index of Biotic Integrity (IBI) is an EPA supported method based on comparison of ecologically important and sensitive fish assemblage variables between potentially disturbed and reference (i.e., undisturbed) sites. It is designed to assess the ability of a stream to support a self-sustaining biological community and ecological processes typical of undisturbed, natural conditions. Since many types of contaminants can bioaccumulate, fish tissue contaminant data were used to determine the types of chemicals fish were exposed to and their relative magnitudes among IOUs. The Fish Health Assessment Index (HAI) is an EPA supported method for assessing

  14. Summary of operations and performance of the Murdock site restoration project in 2007.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2008-06-03

    This document summarizes the performance of the groundwater and surface water restoration systems installed by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) at the former CCC/USDA grain storage facility in Murdock, Nebraska, during the second full year of system operation, from January 1 through December 31, 2007. Performance in June 2005 through December 2006 was reported previously (Argonne 2007). In the Murdock project, several innovative technologies are being used to remove carbon tetrachloride contamination from a shallow aquifer underlying the town, as well as from water naturally discharged to the surface at the headwaters of a small creek (a tributary to Pawnee Creek) north of the town (Figure 1.1). The restoration activities at Murdock are being conducted by the CCC/USDA as a non-time-critical removal action under the regulatory authority and supervision of the U.S. Environmental Protection Agency (EPA), Region VII. Argonne National Laboratory assisted the CCC/USDA by providing technical oversight for the restoration effort and facilities during this review period. Included in this report are the results of all sampling and monitoring activities performed in accord with the EPA-approved Monitoring Plan for this site (Argonne 2006), as well as additional investigative activities conducted during the review period. The annual performance reports for the Murdock project assemble information that will become part of the five-year review and evaluation of the remediation effort. This review will occur in 2010. This document presents overviews of the treatment facilities (Section 2) and site operations and activities (Section 3), then describes the groundwater, surface water, vegetation, and atmospheric monitoring results (Section 4) and modifications and costs during the review period (Section 5). Section 6 summarizes the current period of operation. A gallery of photographs of the Murdock project is in Appendix A. A brief

  15. An operational coupled wave-current forecasting system for the northern Adriatic Sea

    Science.gov (United States)

    Russo, A.; Coluccelli, A.; Deserti, M.; Valentini, A.; Benetazzo, A.; Carniel, S.

    2012-04-01

    Since 2005 an Adriatic implementation of the Regional Ocean Modeling System (AdriaROMS) is being producing operational short-term forecasts (72 hours) of some hydrodynamic properties (currents, sea level, temperature, salinity) of the Adriatic Sea at 2 km horizontal resolution and 20 vertical s-levels, on a daily basis. The main objective of AdriaROMS, which is managed by the Hydro-Meteo-Clima Service (SIMC) of ARPA Emilia Romagna, is to provide useful products for civil protection purposes (sea level forecasts, outputs to run other forecasting models as for saline wedge, oil spills and coastal erosion). In order to improve the forecasts in the coastal area, where most of the attention is focused, a higher resolution model (0.5 km, again with 20 vertical s-levels) has been implemented for the northern Adriatic domain. The new implementation is based on the Coupled-Ocean-Atmosphere-Wave-Sediment Transport Modeling System (COAWST)and adopts ROMS for the hydrodynamic and Simulating WAve Nearshore (SWAN) for the wave module, respectively. Air-sea fluxes are computed using forecasts produced by the COSMO-I7 operational atmospheric model. At the open boundary of the high resolution model, temperature, salinity and velocity fields are provided by AdriaROMS while the wave characteristics are provided by an operational SWAN implementation (also managed by SIMC). Main tidal components are imposed as well, derived from a tidal model. Work in progress is oriented now on the validation of model results by means of extensive comparisons with acquired hydrographic measurements (such as CTDs or XBTs from sea-truth campaigns), currents and waves acquired at observational sites (including those of SIMC, CNR-ISMAR network and its oceanographic tower, located off the Venice littoral) and satellite-derived wave-heights data. Preliminary results on the forecast waves denote how, especially during intense storms, the effect of coupling can lead to significant variations in the wave

  16. Overview of Nevada Test Site Radioactive and Mixed Waste Disposal Operations

    Energy Technology Data Exchange (ETDEWEB)

    J.T. Carilli; S.K. Krenzien; R.G. Geisinger; S.J. Gordon; B. Quinn

    2009-03-01

    The U.S. Department of Energy (DOE), National Nuclear Security Administration Nevada Site Office Environmental Management Program is responsible for carrying out the disposal of on-site and off-site generated low-level radioactive waste (LLW) and low-level radioactive mixed waste (MW) at the Nevada Test Site (NTS). Core elements of this mission are ensuring safe and cost-effective disposal while protecting workers, the public, and the environment. This paper focuses on the impacts of new policies, processes, and opportunities at the NTS related to LLW and MW. Covered topics include: the first year of direct funding for NTS waste disposal operations; zero tolerance policy for non-compliant packages; the suspension of mixed waste disposal; waste acceptance changes; DOE Consolidated Audit Program (DOECAP) auditing; the 92-Acre Area closure plan; new eligibility requirements for generators; and operational successes with unusual waste streams.

  17. Nuclear axial current operators to fourth order in chiral effective field theory

    OpenAIRE

    Krebs, H; Epelbaum, E.; Meißner, U.-G

    2016-01-01

    We present the complete derivation of the nuclear axial charge and current operators as well as the pseudoscalar operators to fourth order in the chiral expansion relative to the dominant one-body contribution using the method of unitary transformation. We demonstrate that the unitary ambiguity in the resulting operators can be eliminated by the requirement of renormalizability and by matching of the pion-pole contributions to the nuclear forces. We give expressions for the renormalized singl...

  18. Pre-operative and early post-operative factors associated with surgical site infection after laparoscopic sleeve gastrectomy.

    Science.gov (United States)

    Ruiz-Tovar, Jaime; Oller, Inmaculada; Llavero, Carolina; Arroyo, Antonio; Muñoz, Jose Luis; Calero, Alicia; Diez, María; Zubiaga, Lorea; Calpena, Rafael

    2013-08-01

    Surgical procedures on obese patients are expected to have a high incidence of surgical site infection (SSI). The identification of pre-operative or early post-operative risk factors for SSI may help the surgeon to identify subjects in risk and adequately optimize their status. We conducted a study of the association of comorbidities and pre- and post-operative analytical variables with SSI following laparoscopic sleeve gastrectomy for the treatment of morbid obesity. We performed a prospective study of all morbidly obese patients undergoing laparoscopic sleeve gastrectomy as a bariatric procedure between 2007 and 2011. An association of clinical and analytical variables with SSI was investigated. The study included 40 patients with a mean pre-operative body mass index (BMI) of 51.2±7.9 kg/m(2). Surgical site infections appeared in three patients (7.5%), of whom two had an intra-abdominal abscess located in the left hypochondrium and the third had a superficial incisional SSI. Pre-operatively, a BMI >45 kg/m(2) (OR 8.7; p=0.008), restrictive disorders identified by pulmonary function tests (OR 10.0; p=0.012), a serum total protein concentration 30 mcg/dL (OR 13.0; p=0.003), and a mean corpuscular volume (MCV) 128 mg/dL (OR 4.7; p=0.012) and hemoglobin <11g/dL (OR 7.5; p=0.002) were associated with SSI. The study supports the role of restrictive lung disorders and the values specified above for preoperative BMI, serum total protein and cortisol concentrations, and MCV, and of post-operative anemia and hyperglycemia as risk factors for SSI. In these situations, the surgeon must be aware of and seek to control these risk factors.

  19. Application for Permit to Operate a Class II Solid Waste Disposal Site at the Nevada Test Site - U10c Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Programs

    2010-03-31

    The Nevada Test Site (NTS) is located approximately 105 km (65 mi) northwest of Las Vegas, Nevada. National Nuclear Security Administration Nevada Site Office (NNSA/NSO) is the federal lands management authority for the NTS and National Security Technologies LLC (NSTec) is the Management and Operations contractor. Access on and off the NTS is tightly controlled, restricted, and guarded on a 24-hour basis. The NTS is posted with signs along its entire perimeter. NSTec is the operator of all solid waste disposal sites on the NTS. The site will be used for the disposal of refuse, rubbish, garbage, sewage sludge, pathological waste, Asbestos-Containing Material (ACM), industrial solid waste, hydrocarbon-burdened soil, hydrocarbon-burdened demolition and construction waste, and other inert waste (hereafter called permissible waste). Waste containing free liquids or regulated under Subtitle C of the Resource Conservation and Recovery Act (RCRA) will not be accepted for disposal at the site. Waste regulated under the Toxic Substance Control Act (TSCA), excluding Polychlorinated Biphenyl [PCB], Bulk Product Waste (see Section 6.2.5) and ACM (see Section 6.2.2.2) will not be accepted for disposal at the site. The disposal site will be used as the sole depository of permissible waste which is: (1) Generated by entities covered under the U.S. Environmental Protection Agency (EPA) Hazardous Waste Generator Identification Number for the NTS; (2) Generated at sites identified in the Federal Facilities Agreement and Consent Order (FFACO); (3) Sensitive records and media, including documents, vugraphs, computer disks, typewriter ribbons, magnetic tapes, etc., generated by NNSA/NSO or its contractors; (4) ACM generated by NNSA/NSO or its contractors according to Section 6.2.2.2, as necessary; (5) Hydrocarbon-burdened soil and solid waste from areas covered under the EPA Hazardous Waste Generator Identification Number for the NTS; (6) Other waste on a case-by-case concurrence by

  20. Formation of Marketing Activity on Organisation and Support of a Corporate Site of Companies That Operate in the Consumer Market

    Directory of Open Access Journals (Sweden)

    Yarym-Agayev Oleksandr M.

    2014-03-01

    Full Text Available The article considers main issues of organisation of Internet marketing at small and medium enterprises of Ukraine, shows a necessity of development and marketing support of the site and provides recommendations on development, implementation and maintenance of corporate sites for marketing and advertising managers. The article considers such directions of operation with the site as analysis of sites of competitors, development of a corporate site, information provision of the site, site indexation and its promotion in search engines, placing site links at information portals, creation of pages in social networks, work at forums, information mailings, operation with site analytics and ensuring feedback with the site visitors. The listed recommendations would allow increase the site image, attract new clients, organise efficient co-operation with specialists on development and promotion of the site and achieve the maximal effect from this source of advertisement and sales.

  1. The role of pre-operative and post-operative glucose control in surgical-site infections and mortality.

    Directory of Open Access Journals (Sweden)

    Christie Y Jeon

    Full Text Available BACKGROUND AND OBJECTIVE: The impact of glucose control on surgical-site infection (SSI and death remains unclear. We examined how pre- and post-operative glucose levels and their variability are associated with the risk of SSI or in-hospital death. METHODS: This retrospective cohort study employed data on 13,800 hospitalized patients who underwent a surgical procedure at a large referral hospital in New York between 2006 and 2008. Over 20 different sources of electronic data were used to analyze how thirty-day risk of SSI and in-hospital death varies by glucose levels and variability. Maximum pre- and post-operative glucose levels were determined for 72 hours before and after the operation and glucose variability was defined as the coefficient of variation of the glucose measurements. We employed logistic regression to model the risk of SSI or death against glucose variables and the following potential confounders: age, sex, body mass index, duration of operation, diabetes status, procedure classification, physical status, emergency status, and blood transfusion. RESULTS: While association of pre- and post-operative hyperglycemia with SSI were apparent in the crude analysis, multivariate results showed that SSI risk did not vary significantly with glucose levels. On the other hand, in-hospital deaths were associated with pre-operative hypoglycemia (OR = 5.09, 95% CI (1.80, 14.4 and glucose variability (OR = 1.14, 95% CI (1.03, 1.27 for 10% increase in coefficient of variation. CONCLUSION: In-hospital deaths occurred more often among those with pre-operative hypoglycemia and higher glucose variability. These findings warrant further investigation to determine whether stabilization of glucose and prevention of hypoglycemia could reduce post-operative deaths.

  2. Environmental assessment for the construction, operation, and decommissioning of the Waste Segregation Facility at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-01-01

    This Environmental Assessment (EA) has been prepared by the Department of Energy (DOE) to assess the potential environmental impacts associated with the construction, operation and decontamination and decommissioning (D&D) of the Waste Segregation Facility (WSF) for the sorting, shredding, and compaction of low-level radioactive waste (LLW) at the Savannah River Site (SRS) located near Aiken, South Carolina. The LLW to be processed consists of two waste streams: legacy waste which is currently stored in E-Area Vaults of SRS and new waste generated from continuing operations. The proposed action is to construct, operate, and D&D a facility to process low-activity job-control and equipment waste for volume reduction. The LLW would be processed to make more efficient use of low-level waste disposal capacity (E-Area Vaults) or to meet the waste acceptance criteria for treatment at the Consolidated Incineration Facility (CIF) at SRS.

  3. Site operator program final report for fiscal years 1992 through 1996

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J.E. [Lockheed Martin Idaho Technologies Co., Idaho Falls, ID (United States). Idaho National Engineering and Environmental Lab.; Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Birasco, S. [Los Angeles Dept. of Water and Power, CA (United States)] [and others

    1998-01-01

    The Site Operator Program was an electric vehicle testing and evaluation program sponsored by US Department of Energy and managed at the Idaho National Engineering and Environmental Laboratory. The Program`s goals included the field evaluation of electric vehicles in real-world applications and environments; the support of electric vehicle technology advancement; the development of infrastructure elements necessary to support significant electric vehicle use; and increasing the awareness and acceptance of electric vehicles. This report covers Program activities from 1992 to 1996. The Site Operator Program ended in September 1996, when it was superseded by the Field Operations Program. Electric vehicle testing included baseline performance testing, which was performed in conjunction with EV America. The baseline performance parameters included acceleration, braking, range, energy efficiency, and charging time. The Program collected fleet operations data on electric vehicles operated by the Program`s thirteen partners, comprising electric utilities, universities, and federal agencies. The Program`s partners had over 250 electric vehicles, from vehicle converters and original equipment manufacturers, in their operating fleets. Test results are available via the World Wide Web site at http://ev.inel.gov/sop.

  4. Pre-operative urinary tract infection: is it a risk factor for early surgical site infection with hip fracture surgery? A retrospective analysis.

    Science.gov (United States)

    Yassa, Rafik Rd; Khalfaoui, Mahdi Y; Veravalli, Karunakar; Evans, D Alun

    2017-03-01

    The aims of the current study were to determine whether pre-operative urinary tract infections in patients presenting acutely with neck of femur fractures resulted in a delay to surgery and whether such patients were at increased risk of developing post-operative surgical site infections. A retrospective review of all patients presenting with a neck of femur fracture, at a single centre over a one-year period. The hospital hip fracture database was used as the main source of data. UK University Teaching Hospital. All patients (n = 460) presenting across a single year study period with a confirmed hip fracture. The presence of pre-operative urinary tract infection, the timing of surgical intervention, the occurrence of post-operative surgical site infection and the pathogens identified. A total of 367 patients were operated upon within 24 hours of admission. Urinary infections were the least common cause of delay. A total of 99 patients (21.5%) had pre-operative urinary tract infection. Post-operatively, a total of 57 (12.4%) patients developed a surgical site infection. Among the latter, 31 (54.4%) did not have a pre-operative urinary infection, 23 (40.4%) patients had a pre-operative urinary tract infection, 2 had chronic leg ulcers and one patient had a pre-operative chest infection. Statistically, there was a strong relationship between pre-operative urinary tract infection and the development of post-operative surgical site infection (p-value: 0.0005). The results of our study indicate that pre-operative urinary tract infection has a high prevalence amongst those presenting with neck of femur fractures, and this is a risk factor for the later development of post-operative surgical site infection.

  5. A preliminary study for the development of indices and the current state of surgical site infections (SSIs) in Korea: the Korean Surgical Site Infection Surveillance (KOSSIS) program.

    Science.gov (United States)

    Park, Sun Jin; Lee, Kil Yeon; Park, Ji Won; Lee, Jae Gil; Choi, Hee Jung; Chun, Hee Kyung; Kang, Jung Gu

    2015-03-01

    We aimed to develop an effective system for surgical site infection (SSI) surveillance and examine the current domestic state of SSIs for common abdominal surgeries in Korea. The Korean Surgical Site Infection Surveillance (KOSSIS) program was developed as an SSI surveillance system. A prospective multicenter study in nine university-affiliated or general hospitals was conducted for patients who underwent gastrectomy, cholecystectomy, appendectomy, colectomy, or proctectomy between August 16 and September 30 in 2012. Patients were monitored for up to 30 days by combining direct observation and a postdischarge surgeon survey. Data on SSIs were prospectively collected with KOSSIS secretarial support according to a common protocol. Operation-specific SSI rates were stratified according to risk factors and compared with data from the Korean Nosocomial Infections Surveillance System (KONIS) and National Healthcare Safety Network. A focus group interview was conducted with participating hospitals for feedback. A total of 1,088 operations were monitored: 207 gastrectomies, 318 cholecystectomies, 270 appendectomies, 197 colectomies, and 96 proctectomies. Operation-specific SSI rates determined by the KOSSIS program were substantially higher than those found in KONIS (7.73% [95% confidence interval, 4.5%-12.3%] vs. 3.4% for gastrectomies, 10.15% [95% confidence interval, 6.1%-15.2%] vs. 4.0% for colectomy, and 13.5% [95% confidence interval, 7.4%-22.0%] vs. 4.2% for proctectomy). Despite a short surveillance period and heterogenous group of hospitals, our results suggest that KOSSIS could be a useful program to enhance SSI surveillance in Korea.

  6. Site Environmental Report for Calendar Year 2000. DOE Operations at The Boeing Company, Rocketdyne Propulsion & Power

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Samuels, Sandy [The Boeing Company, Canoga Park, CA (United States); Lee, Majelle [The Boeing Company, Canoga Park, CA (United States)

    2001-09-01

    This Annual Site Environmental Report (ASER) for 2000 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Rocketdyne Santa Susana Field Laboratory (SSFL). In the past, these operations included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials, under the former Atomics International (AI) Division. Other activities included the operation of large-scale liquid metal facilities for testing of liquid metal fast breeder components at the Energy Technology Engineering Center (ETEC), a government-owned company-operated, test facility within Area IV. All nuclear work was terminated in 1988, and subsequently, all radiological work has been directed toward decontamination and decommissioning (D&D) of the previously used nuclear facilities and associated site areas. Large-scale D&D activities of the sodium test facilities began in 1996. Results of the radiological monitoring program for the calendar year of 2000 continue to indicate no significant releases of radioactive material from Rocketdyne sites. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. All radioactive wastes are processed for disposal at DOE disposal sites and other sites approved by DOE and licensed for radioactive waste. Liquid radioactive wastes are not released into the environment and do not constitute an exposure pathway.

  7. Compliance with Operational Circular No. 2 on conditions of access to the fenced CERN sites

    CERN Multimedia

    Relations with the Host States Service

    2004-01-01

    The purpose of Operational Circular No. 2 is to contribute to the protection of people and property by defining the conditions of access to the Organization's fenced sites. However, recently, the services concerned have noted a significant increase in the instances of non-compliance with those conditions that cannot be tolerated, for example: use of CERN access cards by people, other than the cardholders themselves, in order to gain access to facilities without having attended the required safety course; speeding, particularly on Route Gregory and Route Weisskopf; driving in and out of the site on the wrong side of the road; parking on spaces set aside for the disabled; nuisance parking, especially in the proximity of the Restaurants; the dumping of wrecked vehicles. As the aforementioned instances of non-compliance can lead to dangerous situations, the Organization reserves the right to apply the penalties provided for under paragraph 26 of Operational Circular No. 2, namely to refuse access to the site...

  8. REMINDER - Compliance with Operational Circular No. 2 on conditions of access to the fenced CERN sites

    CERN Multimedia

    Relations with the Host States Service

    2004-01-01

    The purpose of Operational Circular No. 2 is to contribute to the protection of people and property by defining the conditions of access to the Organization's fenced sites. However, recently, the services concerned have noted a significant increase in the instances of non-compliance with those conditions that cannot be tolerated, for example: use of CERN access cards by people, other than the cardholders themselves, in order to gain access to facilities without having attended the required safety course; speeding, particularly on Route Gregory and Route Weisskopf; driving in and out of the site on the wrong side of the road; parking on spaces set aside for the disabled; nuisance parking, especially in the proximity of the Restaurants; the dumping of wrecked vehicles. As the aforementioned instances of non-compliance can lead to dangerous situations, the Organization reserves the right to apply the penalties provided for under paragraph 26 of Operational Circular No. 2, namely to refuse access to the site ...

  9. Advance pre-operative chlorhexidine reduces the incidence of surgical site infections in knee arthroplasty.

    Science.gov (United States)

    Zywiel, Michael G; Daley, Jacqueline A; Delanois, Ronald E; Naziri, Qais; Johnson, Aaron J; Mont, Michael A

    2011-07-01

    Surgical site infections following elective knee arthroplasties occur most commonly as a result of colonisation by the patient's native skin flora. The purpose of this study was to evaluate the incidence of deep surgical site infections in knee arthroplasty patients who used an advance cutaneous disinfection protocol and who were compared to patients who had peri-operative preparation only. All adult reconstruction surgeons at a single institution were approached to voluntarily provide patients with chlorhexidine gluconate-impregnated cloths and a printed sheet instructing their use the night before and morning of surgery. Records for all knee arthroplasties performed between January 2007 and December 2008 were reviewed to determine the incidence of deep incisional and periprosthetic surgical site infections. Overall, the advance pre-operative protocol was used in 136 of 912 total knee arthroplasties (15%). A lower incidence of surgical site infection was found in patients who used the advance cutaneous preparation protocol as compared to patients who used the in-hospital protocol alone. These findings were maintained when patients were stratified by surgical infection risk category. No surgical site infections occurred in the 136 patients who completed the protocol as compared to 21 infections in 711 procedures (3.0%) performed in patients who did not. Patient-directed skin disinfection using chlorhexidine gluconate-impregnated cloths the evening before, and the morning of, elective knee arthroplasty appeared to effectively reduce the incidence of surgical site infection when compared to patients who underwent in-hospital skin preparation only.

  10. Transient Inverse Calibration of Hanford Site-Wide Groundwater Model to Hanford Operational Impacts - 1943 to 1996

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Charles R.; Bergeron, Marcel P.; Wurstner, Signe K.; Thorne, Paul D.; Orr, Samuel; Mckinley, Mathew I.

    2001-05-31

    This report describes a new initiative to strengthen the technical defensibility of predictions made with the Hanford site-wide groundwater flow and transport model. The focus is on characterizing major uncertainties in the current model. PNNL will develop and implement a calibration approach and methodology that can be used to evaluate alternative conceptual models of the Hanford aquifer system. The calibration process will involve a three-dimensional transient inverse calibration of each numerical model to historical observations of hydraulic and water quality impacts to the unconfined aquifer system from Hanford operations since the mid-1940s.

  11. Transient Inverse Calibration of Hanford Site-Wide Groundwater Model to Hanford Operational Impacts - 1943 to 1996

    Energy Technology Data Exchange (ETDEWEB)

    Cole, Charles R.; Bergeron, Marcel P.; Wurstner, Signe K.; Thorne, Paul D.; Orr, Samuel; Mckinley, Mathew I.

    2001-05-31

    This report describes a new initiative to strengthen the technical defensibility of predictions made with the Hanford site-wide groundwater flow and transport model. The focus is on characterizing major uncertainties in the current model. PNNL will develop and implement a calibration approach and methodology that can be used to evaluate alternative conceptual models of the Hanford aquifer system. The calibration process will involve a three-dimensional transient inverse calibration of each numerical model to historical observations of hydraulic and water quality impacts to the unconfined aquifer system from Hanford operations since the mid-1940s.

  12. Operating Water Cherenkov Detectors in high altitude sites for the Large Aperture GRB Observatory

    CERN Document Server

    Allard, D; Asorey, H; Barros, H; Bertou, X; Castillo, M; Chirinos, J M; De Castro, A; Flores, S; González, J; Berisso, M Gomez; Grajales, J; Guada, C; Day, W R Guevara; Ishitsuka, J; López, J A; Martínez, O; Melfo, A; Meza, E; Loza, P Miranda; Barbosa, E Moreno; Murrugarra, C; Núñez, L A; Ormachea, L J Otiniano; Pérez, G; Perez, Y; Ponce, E; Quispe, J; Quintero, C; Rivera, H; Rosales, M; Rovero, A C; Saavedra, O; Salazar, H; Tello, J C; Peralda, R Ticona; Varela, E; Velarde, A; Villaseñor, L; Wahl, D; Zamalloa, M A

    2009-01-01

    Water Cherenkov Detectors (WCD) are efficient detectors for detecting GRBs in the 10 GeV - 1 TeV energy range using the single particle technique, given their sensitivity to low energy secondary photons produced by high energy photons when cascading in the atmosphere. The Large Aperture GRB Observatory (LAGO) operates arrays of WCD in high altitude sites (above 4500 m a.s.l.) in Bolivia, Mexico and Venezuela, with planned extension to Peru. Details on the operation and stability of these WCD in remote sites with high background rates of particles will be detailed, and compared to simulations. Specific issues due to operation at high altitude, atmospheric effects and solar activity, as well as possible hardware enhancements will also be presented.

  13. Effect of Age, Adernaline and Operation Site on Duration of Caudal Analgesia in Paediatric Patients

    Directory of Open Access Journals (Sweden)

    Kharirat Mohd., Yasir,G.A.Mir

    2003-04-01

    Full Text Available The effect ofage, operative site and addition of 1: 200,000 adrenaline to bupivacaine was evaluatedon the duration ofpost operative analgesia after caudal block in 200 children between the age groupof 1 year to 14 years. Anaesthesia was induced and maintained on Halothane/N20I02• After thiscaudal block was performed with 0.5 mllkg of0.25% bupivacaine in one group of 100 Children andwith 0.25% bupivacaine with adrenaline 1 : 200,000 in another 100 children. The duration of postoperative analgesia was noted to be significantly longer in young children, in children having penoscrotaloperations and when adrenaline was added to bupivacaine. Conclusion was drawn that durationofpost-operative analgesia depended upon age, site and addition of adrenaline to bupivacaine.

  14. The development of safe high current operation in JET-ILW

    Energy Technology Data Exchange (ETDEWEB)

    Rimini, Fernanda G., E-mail: fernanda.rimini@ccfe.ac.uk [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Alves, Diogo [Instituto de Plasmas e Fusão Nuclear, IST, Universidade de Lisboa (Portugal); Arnoux, Gilles [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Baruzzo, Matteo [Associazione EURATOM-ENEA sulla Fusione, Consorzio RFX Padova (Italy); Belonohy, Eva [Max-Planck-Institut für Plasmaphysik, 85748 Garching (Germany); Carvalho, Ivo [Instituto de Plasmas e Fusão Nuclear, IST, Universidade de Lisboa (Portugal); Felton, Robert [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Joffrin, Emmanuel [IRFM-CEA, Centre de Cadarache, 13108 Sant-Paul-lez-Durance (France); Lomas, Peter; McCullen, Paul [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Neto, Andre [Fusion for Energy, 08019 Barcelona (Spain); Nunes, Isabel [Instituto de Plasmas e Fusão Nuclear, IST, Universidade de Lisboa (Portugal); Reux, Cedric [IRFM-CEA, Centre de Cadarache, 13108 Sant-Paul-lez-Durance (France); Stephen, Adam; Valcarcel, Daniel [CCFE, Culham Science Centre, Abingdon, Oxon OX14 3DB (United Kingdom); Wiesen, Sven [IEK-4, Forschungszentrum Jüulich GmbH, Partner in the Trilateral Euregio Cluster, Juelich (Germany)

    2015-10-15

    Highlights: • JET is unique in its capability to operate in DT and at high plasma current. • Studies of high current H-mode are integral part of JET ITER-like Wall programme. • Focus is on safety wrt transient & steady-state heat loads on ILW components. • Early real-time detection of off-normal events and disruption effects mitigation. • This work successfully delivered H-mode scenario up to 4 MA. - Abstract: The JET tokamak is unique amongst present fusion devices in its capability to operate at high plasma current, providing the closest plasma parameters to ITER. The physics benefits of high current operation have to be balanced against the risks to the integrity of the machine due to high force disruptions. The installation of the ITER-Like Wall (ILW) has added risks due to the thermal characteristics of the metal Plasma Facing Components. This paper describes the operational aspects of the scientific development of high current H-mode plasmas with the ILW, focusing on disruption prediction, avoidance and amelioration. The development yielded baseline H-mode plasmas up to 4 MA/3.74 T, comparable to the maximum current achieved in JET in Carbon-Wall (CFC) conditions with similar divertor geometry.

  15. Crystallization In High Level Waste (HLW) Glass Melters: Operational Experience From The Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K. M.

    2014-02-27

    processing strategy for the Hanford Tank Waste Treatment and Immobilization Plant (WTP). The basis of this alternative approach is an empirical model predicting the crystal accumulation in the WTP glass discharge riser and melter bottom as a function of glass composition, time, and temperature. When coupled with an associated operating limit (e.g., the maximum tolerable thickness of an accumulated layer of crystals), this model could then be integrated into the process control algorithms to formulate crystal tolerant high level waste (HLW) glasses targeting higher waste loadings while still meeting process related limits and melter lifetime expectancies. This report provides a review of the scaled melter testing that was completed in support of the Defense Waste Processing Facility (DWPF) melter. Testing with scaled melters provided the data to define the DWPF operating limits to avoid bulk (volume) crystallization in the un-agitated DWPF melter and provided the data to distinguish between spinels generated by K-3 refractory corrosion versus spinels that precipitated from the HLW glass melt pool. This report includes a review of the crystallization observed with the scaled melters and the full scale DWPF melters (DWPF Melter 1 and DWPF Melter 2). Examples of actual DWPF melter attainment with Melter 2 are given. The intent is to provide an overview of lessons learned, including some example data, that can be used to advance the development and implementation of an empirical model and operating limit for crystal accumulation for WTP. Operation of the first and second (current) DWPF melters has demonstrated that the strategy of using a liquidus temperature predictive model combined with a 100 °C offset from the normal melter operating temperature of 1150 °C (i.e., the predicted liquidus temperature (TL) of the glass must be 1050 °C or less) has been successful in preventing any detrimental accumulation of spinel in the DWPF melt pool, and spinel has not been

  16. Prolonged Operative Duration Increases Risk of Surgical Site Infections: A Systematic Review.

    Science.gov (United States)

    Cheng, Hang; Chen, Brian Po-Han; Soleas, Ireena M; Ferko, Nicole C; Cameron, Chris G; Hinoul, Piet

    The incidence of surgical site infection (SSI) across surgical procedures, specialties, and conditions is reported to vary from 0.1% to 50%. Operative duration is often cited as an independent and potentially modifiable risk factor for SSI. The objective of this systematic review was to provide an in-depth understanding of the relation between operating time and SSI. This review included 81 prospective and retrospective studies. Along with study design, likelihood of SSI, mean operative times, time thresholds, effect measures, confidence intervals, and p values were extracted. Three meta-analyses were conducted, whereby odds ratios were pooled by hourly operative time thresholds, increments of increasing operative time, and surgical specialty. Pooled analyses demonstrated that the association between extended operative time and SSI typically remained statistically significant, with close to twice the likelihood of SSI observed across various time thresholds. The likelihood of SSI increased with increasing time increments; for example, a 13%, 17%, and 37% increased likelihood for every 15 min, 30 min, and 60 min of surgery, respectively. On average, across various procedures, the mean operative time was approximately 30 min longer in patients with SSIs compared with those patients without. Prolonged operative time can increase the risk of SSI. Given the importance of SSIs on patient outcomes and health care economics, hospitals should focus efforts to reduce operative time.

  17. The role and importance of UAV within the current theaters of operations

    Directory of Open Access Journals (Sweden)

    Niculae MARIN

    2010-06-01

    Full Text Available Current theaters of operations are not limited to battlefields, but they are much morediversified, including the fight against the international terrorism phenomenon, the social conflicts (ofreligious, political, economic and separatist nature within several countries, thus supplying somepolitical-military conflicts within different states and areas of the world. The armed interference mustbe done based on some highly accurate information that must be gathered without endangering thehuman lives. This is the role currently played by the unmanned air vehicles (UAVs; they can performseveral functions: surveillance, information gathering, data storage and their transmission to theground stations, including the function of interference, when needed. This paper presents, within theabove context, the status of the current theaters of operations and of the UAVs performing differentmissions within these theaters, together with their role and importance in warfare operations.

  18. Surgical site infections in dermatologic surgery: etiology, pathogenesis, and current preventative measures.

    Science.gov (United States)

    Saleh, Karim; Schmidtchen, Artur

    2015-05-01

    Surgical site infections (SSIs) after dermatologic surgery continue to represent undesirable complications that affect patients in several aspects. The etiology and pathogenesis of SSIs are not completely understood, and as a result, current preventative measures are debatable. To review and summarize the current available literature specific to SSIs in dermatologic surgery. The pathogenesis of SSIs, factors contributing to SSIs, current preventative guidelines, and evidence supporting their use are explored. A review of the medical literature. Most measures used to prevent SSIs in dermatologic surgery are based on studies of wounds in general surgery. Evidence specific to dermatologic surgery is scarce. More research related to the pathogenesis of SSIs is needed to establish effective preventative measures that are key to reducing incidences of SSIs.

  19. Results of Current Density Distribution Mapping in PEM Fuel Cells Dependent on Operation Parameters

    Directory of Open Access Journals (Sweden)

    Zbigniew A. Styczynski

    2013-07-01

    Full Text Available This paper presents in situ measurements of a newly developed current density measurement system for proton exchange membrane fuel cells (PEMFC. While the functional principle and technical evaluation of the measurement system were presented in a previous paper, this paper analyzes the influence of various operation parameters, including multiple start-stop operation, at the anode, cathode and cooling locations on the distribution and long-term development of the current density. The system was operated for 500 h over two years with long periods of inactivity between measurements. The measurement results are evaluated and provide additional information on how to optimize the operation modes of fuel cells, including the start and stop of such systems as well as the water balance.

  20. Operational prediction of rip currents using numerical model and nearshore bathymetry from video images

    Science.gov (United States)

    Sembiring, L.; Van Ormondt, M.; Van Dongeren, A. R.; Roelvink, J. A.

    2017-07-01

    Rip currents are one of the most dangerous coastal hazards for swimmers. In order to minimize the risk, a coastal operational-process based-model system can be utilized in order to provide forecast of nearshore waves and currents that may endanger beach goers. In this paper, an operational model for rip current prediction by utilizing nearshore bathymetry obtained from video image technique is demonstrated. For the nearshore scale model, XBeach1 is used with which tidal currents, wave induced currents (including the effect of the wave groups) can be simulated simultaneously. Up-to-date bathymetry will be obtained using video images technique, cBathy 2. The system will be tested for the Egmond aan Zee beach, located in the northern part of the Dutch coastline. This paper will test the applicability of bathymetry obtained from video technique to be used as input for the numerical modelling system by comparing simulation results using surveyed bathymetry and model results using video bathymetry. Results show that the video technique is able to produce bathymetry converging towards the ground truth observations. This bathymetry validation will be followed by an example of operational forecasting type of simulation on predicting rip currents. Rip currents flow fields simulated over measured and modeled bathymetries are compared in order to assess the performance of the proposed forecast system.

  1. Implementation of superconducting fault current limiter for flexible operation in the power substation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chong Suk, E-mail: chong_suk@korea.ac.kr [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of); Lee, Hansang [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Cho, Yoon-sung [Department of Electric and Energy Engineering, Catholic University of Daegu, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-702 (Korea, Republic of); Suh, Jaewan [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of)

    2014-09-15

    Highlights: • The power load concentrated in load centers results in high levels of fault current. • This paper introduces a fault current reduction scheme using SFCLs in substations. • The SFCL is connected in parallel to the bus tie between the two busbars. • The fault current mitigation using SFCLs is verified through PSS/e simulations. - Abstract: The concentration of large-scale power loads located in the metropolitan areas have resulted in high fault current levels during a fault thereby requiring the substation to operate in the double busbar configuration mode. However, the double busbar configuration mode results in deterioration of power system reliability and unbalanced power flow in the adjacent transmission lines which may result in issues such as overloading of lines. This paper proposes the implementation of the superconducting fault current limiter (SFCL) to be installed between the two substation busbars for a more efficient and flexible operation of the substation enabling both single and double busbar configurations depending on the system conditions for guaranteeing power system reliability as well as fault current limitations. Case studies are being performed for the effectiveness of the SFCL installation and results are compared for the cases where the substation is operating in single and double busbar mode and with and without the installation of the SFCL for fault current mitigation.

  2. Energy benchmarking in wastewater treatment plants: the importance of site operation and layout.

    Science.gov (United States)

    Belloir, C; Stanford, C; Soares, A

    2015-01-01

    Energy benchmarking is a powerful tool in the optimization of wastewater treatment plants (WWTPs) in helping to reduce costs and greenhouse gas emissions. Traditionally, energy benchmarking methods focused solely on reporting electricity consumption, however, recent developments in this area have led to the inclusion of other types of energy, including electrical, manual, chemical and mechanical consumptions that can be expressed in kWh/m3. In this study, two full-scale WWTPs were benchmarked, both incorporated preliminary, secondary (oxidation ditch) and tertiary treatment processes, Site 1 also had an additional primary treatment step. The results indicated that Site 1 required 2.32 kWh/m3 against 0.98 kWh/m3 for Site 2. Aeration presented the highest energy consumption for both sites with 2.08 kWh/m3 required for Site 1 and 0.91 kWh/m3 in Site 2. The mechanical energy represented the second biggest consumption for Site 1 (9%, 0.212 kWh/m3) and chemical input was significant in Site 2 (4.1%, 0.026 kWh/m3). The analysis of the results indicated that Site 2 could be optimized by constructing a primary settling tank that would reduce the biochemical oxygen demand, total suspended solids and NH4 loads to the oxidation ditch by 55%, 75% and 12%, respectively, and at the same time reduce the aeration requirements by 49%. This study demonstrated that the effectiveness of the energy benchmarking exercise in identifying the highest energy-consuming assets, nevertheless it points out the need to develop a holistic overview of the WWTP and the need to include parameters such as effluent quality, site operation and plant layout to allow adequate benchmarking.

  3. Site Environmental Report for Calendar Year 2001. DOE Operations at The Boeing Company, Rocketdyne Propulsion & Power

    Energy Technology Data Exchange (ETDEWEB)

    Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Samuels, Sandy [The Boeing Company, Canoga Park, CA (United States); Leee, Majelle [The Boeing Company, Canoga Park, CA (United States)

    2002-09-01

    This Annual Site Environmental Report (ASER) for 2001 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Boeing Rocketdyne Santa Susana Field Laboratory (SSFL). In the past, these operations included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials under the former Atomics International (AI) Division. Other activities included the operation of large-scale liquid metal facilities for testing of liquid metal fast breeder components at the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility within Area IV. All nuclear work was terminated in 1988, and subsequently, all radiological work has been directed toward decontamination and decommissioning (D&D) of the previously used nuclear facilities and associated site areas. Closure of the sodium test facilities began in 1996. Results of the radiological monitoring program for the calendar year of 2001 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. All radioactive wastes are processed for disposal at DOE disposal sites and other sites approved by DOE and licensed for radioactive waste. Liquid radioactive wastes are not released into the environment and do not constitute an exposure pathway. No structural debris from buildings, released for unrestricted use, was transferred to municipal landfills or recycled in 2001.

  4. Marine Benthic Habitats and Seabed Suitability Mapping for Potential Ocean Current Energy Siting Offshore Southeast Florida

    Directory of Open Access Journals (Sweden)

    Amanda Mulcan

    2015-05-01

    Full Text Available This study examines the legal framework for ocean current energy policy and regulation to develop a metric for assessing the biological and geological characteristics of a seabed area with respect to the siting of OCE devices, a framework of criteria by which to assess seabed suitability (seabed suitability framework that can facilitate the siting, and implementation of ocean current energy (OCE projects. Seafloor geology and benthic biological data were analyzed in conjunction with seafloor core sample geostatistical interpolation to locate suitable substrates for OCE anchoring. Existing submarine cable pathways were considered to determine pathways for power transmission cables that circumvent biologically sensitive areas. Suitability analysis indicates that areas east of the Miami Terrace and north of recently identified deep-sea coral mounds are the most appropriate for OCE siting due to abundance of sand/sediment substrate, existing underwater cable route access, and minimal biological presence (i.e., little to no benthic communities. Further reconnaissance requires higher resolution maps of geological substrate and benthic community locations to identify specific OCE development locations, classify benthic conditions, and minimize potentially negative OCE environmental impacts.

  5. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    OpenAIRE

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-01-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma def...

  6. Industrial hygiene support of underground operations at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Porter, P.F.

    1992-07-23

    The Industrial Hygiene Section of the Health Protection Department provides industrial hygiene support of underground operations at the Nevada Test Site. This report describes support operations and summarizes the industrial hygiene data collected from July 31, 1989 through June 30, 1991. Air quality data were collected by means of personnel sampling by active and passive techniques using various kinds of industrial hygiene instrumentation and through localized and general area monitoring. The data collected were used to evaluate underground air quality and quantity requirements; evaluate worker exposures to a variety of air contaminants; determine the applicability and effectiveness of personal protective equipment.

  7. Short Operative Duration and Surgical Site Infection Risk in Hip and Knee Arthroplasty Procedures.

    Science.gov (United States)

    Dicks, Kristen V; Baker, Arthur W; Durkin, Michael J; Anderson, Deverick J; Moehring, Rebekah W; Chen, Luke F; Sexton, Daniel J; Weber, David J; Lewis, Sarah S

    2015-12-01

    To determine the association (1) between shorter operative duration and surgical site infection (SSI) and (2) between surgeon median operative duration and SSI risk among first-time hip and knee arthroplasties. Retrospective cohort study A total of 43 community hospitals located in the southeastern United States. Adults who developed SSIs according to National Healthcare Safety Network criteria within 365 days of first-time knee or hip arthroplasties performed between January 1, 2008 and December 31, 2012. Log-binomial regression models estimated the association (1) between operative duration and SSI outcome and (2) between surgeon median operative duration and SSI outcome. Hip and knee arthroplasties were evaluated in separate models. Each model was adjusted for American Society of Anesthesiology score and patient age. A total of 25,531 hip arthroplasties and 42,187 knee arthroplasties were included in the study. The risk of SSI in knee arthroplasties with an operative duration shorter than the 25th percentile was 0.40 times the risk of SSI in knee arthroplasties with an operative duration between the 25th and 75th percentile (risk ratio [RR], 0.40; 95% confidence interval [CI], 0.38-0.56; P<.01). Short operative duration did not demonstrate significant association with SSI for hip arthroplasties (RR, 1.04; 95% CI, 0.79-1.37; P=.36). Knee arthroplasty surgeons with shorter median operative durations had a lower risk of SSI than surgeons with typical median operative durations (RR, 0.52; 95% CI, 0.43-0.64; P<.01). Short operative durations were not associated with a higher SSI risk for knee or hip arthroplasty procedures in our analysis.

  8. Heating, current drive and energetic particle studies on JET in preparation of ITER operation

    NARCIS (Netherlands)

    Noterdaeme, J. M.; Budny, R.; Cardinali, A.; Castaldo, C.; Cesario, R.; Crisanti, F.; DeGrassie, J.; D' Ippolito, D. A.; Durodie, F.; Ekedahl, A.; Figueiredo, A.; Ingesson, C.; Joffrin, E.; Hartmann, D.; Heikkinen, J.; Hellsten, T.; Jones, T.; Kiptily, V.; Lamalle, P.; Litaudon, X.; Nguyen, F.; Mailloux, J.; Mantsinen, M.; Mayoral, M.; Mazon, D.; Meo, F.; Monakhov, I.; Myra, J. R.; Pamela, J.; Pericoli, V.; Petrov, Y.; Sauter, O.; Sarazin, Y.; Sharapov, S. E.; Tuccillo, A. A.; Van Eester, D.

    2003-01-01

    This paper summarizes the recent work on JET in the three areas of heating, current drive and energetic particles. The achievements have extended the possibilities of JET, have a direct connection to ITER operation and provide new and interesting physics. Toroidal rotation profiles of plasmas heated

  9. Advanced Tokamak current density profiles for non-inductive Tore Supra operation

    Energy Technology Data Exchange (ETDEWEB)

    Kazarian-Vibert, F.; Litaudon, X.; Arslanbekov, R.; Bibet, P.; Froissard, P.; Goniche, M.; Hoang, G.T.; Joffrin, E.; Moreau, D.; Peysson, Y.; Rey, G. [Association Euratom-CEA, Centre d`Etudes de Cadarache, 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee

    1995-12-31

    This document deals with the advanced Tokamak concept concerning self consistent hollow current density profiles. Several Lower Hybrid experiments performed on Tore Supra are presented: the feasibility of the constant-flux operation mode is demonstrated and a new improved confinement regime with a reversed shear has been obtained. (TEC). 12 refs., 5 figs.

  10. Infirmity and injury complexity are risk factors for surgical-site infection after operative fracture care.

    Science.gov (United States)

    Bachoura, Abdo; Guitton, Thierry G; Smith, R Malcolm; Vrahas, Mark S; Zurakowski, David; Ring, David

    2011-09-01

    Orthopaedic surgical-site infections prolong hospital stays, double rehospitalization rates, and increase healthcare costs. Additionally, patients with orthopaedic surgical-site infections (SSI) have substantially greater physical limitations and reductions in their health-related quality of life. However, the risk factors for SSI after operative fracture care are unclear. We determined the incidence and quantified modifiable and nonmodifiable risk factors for SSIs in patients with orthopaedic trauma undergoing surgery. We retrospectively indentified, from our prospective trauma database and billing records, 1611 patients who underwent 1783 trauma-related procedures between 2006 and 2008. Medical records were reviewed and demographics, surgery-specific data, and whether the patients had an SSI were recorded. We determined which if any variables predicted SSI. Six factors independently predicted SSI: (1) the use of a drain, OR 2.3, 95% CI (1.3-3.8); (2) number of operations OR 3.4, 95% CI (2.0-6.0); (3) diabetes, OR 2.1, 95% CI (1.2-3.8); (4) congestive heart failure (CHF), OR 2.8, 95% CI (1.3-6.5); (5) site of injury tibial shaft/plateau, OR 2.3, 95% CI (1.3-4.2); and (6) site of injury, elbow, OR 2.2, 95% CI (1.1-4.7). The risk factors for SSIs after skeletal trauma are most strongly determined by nonmodifiable factors: patient infirmity (diabetes and heart failure) and injury complexity (site of injury, number of operations, use of a drain). Level II, prognostic study. See the Guideline for Authors for a complete description of levels of evidence.

  11. Three computer codes to read, plot and tabulate operational test-site recorded solar data

    Science.gov (United States)

    Stewart, S. D.; Sampson, R. S., Jr.; Stonemetz, R. E.; Rouse, S. L.

    1980-01-01

    Computer programs used to process data that will be used in the evaluation of collector efficiency and solar system performance are described. The program, TAPFIL, reads data from an IBM 360 tape containing information (insolation, flowrates, temperatures, etc.) from 48 operational solar heating and cooling test sites. Two other programs, CHPLOT and WRTCNL, plot and tabulate the data from the direct access, unformatted TAPFIL file. The methodology of the programs, their inputs, and their outputs are described.

  12. A current to voltage converter for cryogenics using a CMOS operational amplifier

    Science.gov (United States)

    Hayashi, K.; Saitoh, K.; Shibayama, Y.; Shirahama, K.

    2009-02-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 106 V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  13. Monticello Mill Tailings Site, Operable Unit lll, Annual Groundwater Report, May 2015 Through April 2016

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Jason [USDOE Office of Legacy Management (LM), Washington, DC (United States); Smith, Fred [Navarro Research and Engineering, Oak Ridge, TN (United States)

    2016-10-01

    This report provides the annual analysis of water quality restoration progress, cumulative through April 2016, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management (LM) Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site, Operable Unit I (OU I), and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. This effectively removed the primary source of groundwater contamination; however, contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern (COC). LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of

  14. Current density distribution mapping in PEM fuel cells as an instrument for operational measurements

    Energy Technology Data Exchange (ETDEWEB)

    Geske, M.; Heuer, M.; Heideck, G.; Styczynski, Z. A. [Otto-von-Guericke University Magdeburg, Chair Electric Power Networks and Renewable Energy Sources, Magdeburg (Germany)

    2010-07-01

    A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC). Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes. (author)

  15. Current Density Distribution Mapping in PEM Fuel Cells as An Instrument for Operational Measurements

    Directory of Open Access Journals (Sweden)

    Martin Geske

    2010-04-01

    Full Text Available A newly developed measurement system for current density distribution mapping has enabled a new approach for operational measurements in proton exchange membrane fuel cells (PEMFC. Taking into account previously constructed measurement systems, a method based on a multi layer printed circuit board was chosen for the development of the new system. This type of system consists of a sensor, a special electronic device and the control and visualization PC. For the acquisition of the current density distribution values, a sensor device was designed and installed within a multilayer printed circuit board with integrated shunt resistors. Varying shunt values can be taken into consideration with a newly developed and evaluated calibration method. The sensor device was integrated in a PEM fuel cell stack to prove the functionality of the whole measurement system. A software application was implemented to visualize and save the measurement values. Its functionality was verified by operational measurements within a PEMFC system. Measurement accuracy and possible negative reactions of the sensor device during PEMFC operation are discussed in detail in this paper. The developed system enables operational measurements for different operating phases of PEM fuel cells. Additionally, this can be seen as a basis for new opportunities of optimization for fuel cell design and operation modes.

  16. Rocketdyne Propulsion and Power DOE Operations annual site environmental report 1997

    Energy Technology Data Exchange (ETDEWEB)

    Robinson, K.S. [ed.

    1998-11-23

    This annual report discusses environmental monitoring at two manufacturing and test sites operated in the Los Angeles area by Rocketdyne Propulsion and Power of Boeing North American, Inc. These are identified as Area 4 of the SSFL and the De Soto site. These sites have been used for research and development (R and D), engineering, and testing in a broad range of technical fields primarily in energy research and nuclear reactor technology. The De Soto site had research and development laboratories involved with nuclear research. This work was terminated in 1995 and only D and D activities will have potential for impact on the environment. Since 1956, Area 4 has been used for work with nuclear materials, including fabricating nuclear reactor fuels, testing nuclear reactors, and dissembling used fuel elements. This work ended in 1988 and subsequent efforts have been directed toward decommissioning and decontamination of the former nuclear facilities. The primary purpose of this report is to present information on environmental and effluent monitoring of DOE-sponsored activities to the regulatory agencies responsible for oversight. Information presented here concentrates on Area 4 at SSFL, which is the only area at SSFL where DOE operations were performed.

  17. Limitations Of The Current State Space Modelling Approach In Multistage Machining Processes Due To Operation Variations

    Science.gov (United States)

    Abellán-Nebot, J. V.; Liu, J.; Romero, F.

    2009-11-01

    The State Space modelling approach has been recently proposed as an engineering-driven technique for part quality prediction in Multistage Machining Processes (MMP). Current State Space models incorporate fixture and datum variations in the multi-stage variation propagation, without explicitly considering common operation variations such as machine-tool thermal distortions, cutting-tool wear, cutting-tool deflections, etc. This paper shows the limitations of the current State Space model through an experimental case study where the effect of the spindle thermal expansion, cutting-tool flank wear and locator errors are introduced. The paper also discusses the extension of the current State Space model to include operation variations and its potential benefits.

  18. Microstructure characterisation of solid oxide electrolysis cells operated at high current density

    DEFF Research Database (Denmark)

    Bowen, Jacob R.; Bentzen, Janet Jonna; Chen, Ming;

    High temperature solid oxide cells can be operated either as fuel cells or electrolysis cells for efficient power generation or production of hydrogen from steam or synthesis gas (H2 + CO) from steam and CO2 respectively. When operated under harsh conditions, they often exhibit microstructural......, microstructure evolution of the Ni-yttria stabilized zirconia (YSZ) is followed as a function of galvanostatic steam electrolysis testing at current densities between -0.5 and -1.0 A cm-2 for periods of up to 750 hours at 800 °C. The volume fraction and size of the percolating Ni particles was statistically...... quantified using the mean linear intercept method as a function of current density and correlated to increases in serial resistance. The above structural changes are then compared in terms of electrode degradation observed during the co-electrolysis of steam and CO2 at current densities up to -1.5 A cm-2...

  19. Remedial investigation/feasibility study work plan for the 100-BC-2 operable unit, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    This work plan and attached supporting project plans establish the operable unit setting and the objectives, procedures, tasks, and schedule for conducting the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA) remedial investigation/feasibility study (RI/FS) for the 100-BC-2 operable unit in the 100 Area of the Hanford Site. The 100 Area is one of four areas at the Hanford Site that are on the US Environmental Protection Agency`s (EPA) National Priorities List under CERCLA. The 100-BC-2 operable unit is one of two source operable units in the 100-B/C Area (Figure ES-1). Source operable units are those that contain facilities and unplanned release sites that are potential sources of hazardous substance contamination. The 100-BC-2 source operable unit contains waste sites that were formerly in the 100-BC-2, 100-BC-3, and 100-BC-4 operable units. Because of their size and geographic location, the waste sites from these two operable units were added to 100-BC-2. This allows for a more efficient and effective investigation of the remaining 100-B/C Reactor area waste sites. The investigative approach to waste sites associated with the 100-BC-2 operable unit are listed in Table ES-1. The waste sites fall into three general categories: high priority liquid waste disposal sites, low priority liquid waste disposal sites, and solid waste burial grounds. Several sites have been identified as candidates for conducting an IRM. Two sites have been identified as warranting additional limited field sampling. The two sites are the 116-C-2A pluto crib, and the 116-C-2C sand filter.

  20. Environmental assessment for device assembly facility operations, Nevada Test Site, Nye County, Nevada. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    The U.S. Department of Energy, Nevada Operations Office (DOE/NV), has prepared an environmental assessment (EA), (DOE/EA-0971), to evaluate the impacts of consolidating all nuclear explosive operations at the newly constructed Device Assembly Facility (DAF) in Area 6 of the Nevada Test Site. These operations generally include assembly, disassembly or modification, staging, transportation, testing, maintenance, repair, retrofit, and surveillance. Such operations have previously been conducted at the Nevada Test Site in older facilities located in Area 27. The DAF will provide enhanced capabilities in a state-of-the-art facility for the safe, secure, and efficient handling of high explosives in combination with special nuclear materials (plutonium and highly enriched uranium). Based on the information and analyses in the EA, DOE has determined that the proposed action would not constitute a major federal action significantly affecting the quality of the human environment within the meaning of the National Environmental Policy Act of 1969 (42 U.S.C. 4321 et seq.). Therefore, an environmental impact statement is not required, and DOE is issuing this finding of no significant impact.

  1. NASA UAS Traffic Management National Campaign Operations across Six UAS Test Sites

    Science.gov (United States)

    Rios, Joseph; Mulfinger, Daniel; Homola, Jeff; Venkatesan, Priya

    2016-01-01

    NASA's Unmanned Aircraft Systems Traffic Management research aims to develop policies, procedures, requirements, and other artifacts to inform the implementation of a future system that enables small drones to access the low altitude airspace. In this endeavor, NASA conducted a geographically diverse flight test in conjunction with the FAA's six unmanned aircraft systems Test Sites. A control center at NASA Ames Research Center autonomously managed the airspace for all participants in eight states as they flew operations (both real and simulated). The system allowed for common situational awareness across all stakeholders, kept traffic procedurally separated, offered messages to inform the participants of activity relevant to their operations. Over the 3- hour test, 102 flight operations connected to the central research platform with 17 different vehicle types and 8 distinct software client implementations while seamlessly interacting with simulated traffic.

  2. US Department of Energy DOE Nevada Operations Office, Nevada Test Site: Underground safety and health standards

    Energy Technology Data Exchange (ETDEWEB)

    1993-05-01

    The Nevada Test Site Underground Safety and Health Standards Working Group was formed at the direction of John D. Stewart, Director, Nevada Test Site Office in April, 1990. The objective of the Working Group was to compile a safety and health standard from the California Tunnel Safety Orders and OSHA for the underground operations at the NTS, (excluding Yucca Mountain). These standards are called the NTS U/G Safety and Health Standards. The Working Group submits these standards as a RECOMMENDATION to the Director, NTSO. Although the Working Group considers these standards to be the most integrated and comprehensive standards that could be developed for NTS Underground Operations, the intent is not to supersede or replace any relevant DOE orders. Rather the intent is to collate the multiple safety and health references contained in DOE Order 5480.4 that have applicability to NTS Underground Operations into a single safety and heath standard to be used in the underground operations at the NTS. Each portion of the standard was included only after careful consideration by the Working Group and is judged to be both effective and appropriate. The specific methods and rationale used by the Working Group are outlined as follows: The letter from DOE/HQ, dated September 28, 1990 cited OSHA and the CTSO as the safety and health codes applicable to underground operations at the NTS. These mandated codes were each originally developed to be comprehensive, i.e., all underground operations of a particular type (e.g., tunnels in the case of the CTSO) were intended to be adequately regulated by the appropriate code. However, this is not true; the Working Group found extensive and confusing overlap in the codes in numerous areas. Other subjects and activities were addressed by the various codes in cursory fashion or not at all.

  3. Minimal invasive single-site surgery in colorectal procedures: Current state of the art

    Directory of Open Access Journals (Sweden)

    Diana Michele

    2011-01-01

    Full Text Available Background: Minimally invasive single-site (MISS surgery has recently been applied to colorectal surgery. We aimed to assess the current state of the art and the adequacy of preliminary oncological results. Methods: We performed a systematic review of the literature using Pubmed, Medline, SCOPUS and Web of Science databases. Keywords used were "Single Port" or "Single-Incision" or "LaparoEndoscopic Single Site" or "SILS™" and "Colon" or "Colorectal" and "Surgery". Results: Twenty-nine articles on colorectal MISS surgery have been published from July 2008 to July 2010, presenting data on 149 patients. One study reported analgesic requirement. The final incision length ranged from 2.5 to 8 cm. Only two studies reported fascial incision length. There were two port site hernias in a series of 13 patients (15.38%. Two "fully laparoscopic" MISS procedures with preparation and achievement of the anastomosis completely intracorporeally are reported. Future site of ileostomy was used as the sole access for the procedures in three studies. Lymph node harvesting, resection margins and length of specimen were sufficient in oncological cases. Conclusions: MISS colorectal surgery is a challenging procedure that seems to be safe and feasible, but the existing clinical evidence is limited. In selected cases, and especially when an ileostomy is planned, colorectal surgery may be an ideal indication for MISS surgery leading to a no-scar surgery. Despite preliminary oncological results showing the feasibility of MISS surgery, we want to stress the need to standardize the technique and carefully evaluate its application in oncosurgery under ethical committee control.

  4. Evaluation of current operating standards for chlorine dioxide in disinfection of dump tank and flume for fresh tomatoes.

    Science.gov (United States)

    Tomás-Callejas, Alejandro; López-Velasco, Gabriela; Valadez, Angela M; Sbodio, Adrian; Artés-Hernández, Francisco; Danyluk, Michelle D; Suslow, Trevor V

    2012-02-01

    Standard postharvest unit operations that rely on copious water contact, such as fruit unloading and washing, approach the criteria for a true critical control point in fresh tomato production. Performance data for approved sanitizers that reflect commercial systems are needed to set standards for audit compliance. This study was conducted to evaluate the efficacy of chlorine dioxide (ClO(2)) for water disinfection as an objective assessment of recent industry-adopted standards for dump tank and flume management in fresh tomato packing operations. On-site assessments were conducted during eight temporally distinct shifts in two Florida packinghouses and one California packinghouse. Microbiological analyses of incoming and washed fruit and dump and flume system water were evaluated. Water temperature, pH, turbidity, conductivity, and oxidation-reduction potential (ORP) were monitored. Reduction in populations of mesophilic and coliform bacteria on fruit was not significant, and populations were significantly higher (P dump tanks but consistently below the detection limit in flumes. Turbidity and conductivity increased with loads of incoming tomatoes. Water temperature varied during daily operations, but pH and ORP mostly remained constant. The industry standard positive temperature differential of 5.5°C between water and fruit pulp was not maintained in tanks during the full daily operation. ORP values were significantly higher in the flume than in the dump tank. A positive correlation was found between ORP and temperature, and negative correlations were found between ORP and turbidity, total mesophilic bacteria, and coliforms. This study provides in-plant data indicating that ClO(2) can be an effective sanitizer in flume and spray-wash systems, but current operational limitations restrict its performance in dump tanks. Under current conditions, ClO(2) alone is unlikely to allow the fresh tomato industry to meet its microbiological quality goals under typical

  5. The logical operator map identifies novel candidate markers for critical sites in patients with atrial fibrillation.

    Science.gov (United States)

    Ravelli, Flavia; Masè, Michela; Cristoforetti, Alessandro; Marini, Massimiliano; Disertori, Marcello

    2014-08-01

    The identification of suitable markers for critical patterns during atrial fibrillation (AF) may be crucial to guide an effective ablation treatment. Single parameter maps, based on dominant frequency and complex fractionated electrograms, have been proposed as a tool for electrogram-guided ablation, however the specificity of these markers is debated. Experimental studies suggest that AF critical patterns may be identified on the basis of specific rate and organization features, where rapid organized and rapid fragmented activities characterize respectively localized sources and critical substrates. In this paper we introduce the logical operator map, a novel mapping tool for a point-by-point identification and localization of AF critical sites. Based on advanced signal and image processing techniques, the approach combines in a single map electrogram-derived rate and organization features with tomographic anatomical detail. The construction of the anatomically-detailed logical operator map is based on the time-domain estimation of atrial rate and organization in terms of cycle length and wave-similarity, the logical combination of these indexes to obtain suitable markers of critical sites, and the multimodal integration of electrophysiological and anatomical information by segmentation and registration techniques. Logical operator maps were constructed in 14 patients with persistent AF, showing the capability of the combined rate and organization markers to identify with high selectivity the subset of electrograms associated with localized sources and critical substrates. The precise anatomical localization of these critical sites revealed the confinement of rapid organized sources in the left atrium with organization and rate gradients towards the surrounding tissue, and the presence of rapid fragmented electrograms in proximity of the sources. By merging in a single map the most relevant electrophysiological and anatomical features of the AF process, the

  6. Pre-operational environmental monitoring plan for the Device Assembly Facility at the Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Ferate, F.D.

    1995-01-01

    Nuclear explosives operations have been and may continue to be an important component of the DOE mission at the NTS. This mission has been to conduct the nation`s nuclear testing program in a safe, secure, and efficient manner while assuring full compliance with state and federal regulations, and DOE order`s and directives. These operations have generally included assembly, disassembly or modification, staging, transportation, and tesbng of nuclear explosive devices. They may also include maintenance, repair, retrofit, and surveillance. The Device Assembly Facility (DAF) was constructed to provide a dedicated facility in which to prepare nuclear explosives assemblies for their intended disposition. This facility will provide for combined operations (replacing two separate facilities) and incorporates state-of-the-art safety and security features while minimizing the risks of environmental impacts. The facility has been completed but not yet operated, so the impacts to be considered will b e based on normal operations and not on the impacts of construction activities. The impacts will arise from nuclear explosives operations that require the handling of high explosives in combination with special nuclear materials. Wastes from operation of the earlier device assembly facilities have included grams of epoxies, pints of solvents, and small quantities of waste explosives. These are hazardous (includes radioactive) wastes and are disposed of in accordance with state and federal regulations. Assuming similar operations at the DAF, non-hazardous (includes non-radioactive) solid waste would be transported to a permitted landfill. Waste explosives would be sent to the Area 11 Explosive Ordnance Disposal Unit. Other hazardous waste would be sent to the Area 5 Radioactive Waste.Management Site for shipment or burial.

  7. Elimination of zero sequence circulating current between parallel operating three-level inverters

    DEFF Research Database (Denmark)

    Li, Kai; Wang, Xiaodong; Dong, Zhenhua

    2016-01-01

    In order to suppress the zero sequence circulating currents (ZSCCs) between parallel operating three level voltage source inverters with common AC and DC buses, a common mode voltage reduction PWM (CMVR-PWM) technique and neural point potentials (NPPs) control based method is proposed in this paper...... strategies, ZSCCs between parallel inverters can be eliminated effectively. This strategy has the advantage of without carrier synchronization and can be utilized to parallel operating inverters with different types of filter. Simulation result validate the proposed ZSCC elimination schemes....

  8. New Voltage-Mode All-pass Filter Topology Employing Single Current Operational Amplifier

    Directory of Open Access Journals (Sweden)

    Hasan Çiçekli

    2016-02-01

    Full Text Available In this paper, a new voltage-mode all-pass filter topology based on single current operational amplifier (COA and the implementation of COA by using current conveyors are presented. The proposed topology employs three admittances and single active circuit element. COA implementation by using current conveyor blocks as sub-circuit contributes to workability of the COA employing circuits by using commercially available integrated circuits that can be employed as current conveyor. The validity of the proposed filter is verified by PSPICE simulation programme by using the MOSIS 0.35 micron CMOS process parameters. The simulation results agree well with the theoretical analysis and the circuit achieve a good total harmonic distortion (THD performance.

  9. Assessment of Electron-Cyclotron-Current-Drive-Assisted Operation in DEMO

    Directory of Open Access Journals (Sweden)

    Marushchenko N.B.

    2012-09-01

    Full Text Available The achievable efficiency for external current drive through electron-cyclotron (EC waves in a demonstration tokamak reactor is discussed. Two possible reactor designs, one for steady state and one for pulsed operation, are considered. It is found that for midplane injection the achievable current drive efficiency is limited by secondharmonic absorption at levels consistent with previous studies. Propagation through the second-harmonic region can be reduced by moving the launch position to the high-field side (this can be obtained by injecting the beam from an upper port in the vacuum vessel. In this case, beam tracing calculations deliver values for the EC current drive efficiency approaching those usually reported for neutral beam current drive.

  10. Current feedback operational amplifiers as fast charge sensitive preamplifiers for photomultiplier read out

    Energy Technology Data Exchange (ETDEWEB)

    Giachero, A; Gotti, C; Maino, M; Pessina, G, E-mail: claudio.gotti@mib.infn.it [INFN - Sezione di Milano-Bicocca, I-20126, Milano (Italy)

    2011-05-01

    Fast charge sensitive preamplifiers were built using commercial current feedback operational amplifiers for fast read out of charge pulses from a photomultiplier tube. Current feedback opamps prove to be particularly well suited for this application where the charge from the detector is large, of the order of one million electrons, and high timing resolution is required. A proper circuit arrangement allows very fast signals, with rise times down to one nanosecond, while keeping the amplifier stable. After a review of current feedback circuit topology and stability constraints, we provide a 'recipe' to build stable and very fast charge sensitive preamplifiers from any current feedback opamp by adding just a few external components. The noise performance of the circuit topology has been evaluated and is reported in terms of equivalent noise charge.

  11. Current feedback operational amplifiers as fast charge sensitive preamplifiers for photomultiplier read out

    Science.gov (United States)

    Giachero, A.; Gotti, C.; Maino, M.; Pessina, G.

    2011-05-01

    Fast charge sensitive preamplifiers were built using commercial current feedback operational amplifiers for fast read out of charge pulses from a photomultiplier tube. Current feedback opamps prove to be particularly well suited for this application where the charge from the detector is large, of the order of one million electrons, and high timing resolution is required. A proper circuit arrangement allows very fast signals, with rise times down to one nanosecond, while keeping the amplifier stable. After a review of current feedback circuit topology and stability constraints, we provide a "recipe" to build stable and very fast charge sensitive preamplifiers from any current feedback opamp by adding just a few external components. The noise performance of the circuit topology has been evaluated and is reported in terms of equivalent noise charge.

  12. Analytical studies on a new lattice hydrodynamic traffic flow model with consideration of traffic current cooperation among three consecutive sites

    Science.gov (United States)

    Li, Zhipeng; Zhong, Chenjie; Chen, Lizhu; Xu, Shangzhi; Qian, Yeqing

    2016-09-01

    In this paper, the original lattice hydrodynamic model of traffic flow is extended to take into account the traffic current cooperation among three consecutive sites. The basic idea of the new consideration is that the cooperative traffic current of the considered site is determined by the traffic currents of the site itself, the immediately preceding site and the immediately following one. The stability criterion of the extended model is obtained by applying the linear stability analysis. The result reveals the traffic current cooperation of the immediately preceding site is positive correlation with the stability of traffic system, while negative correlation is found between the traffic stability and the traffic current cooperation of the nearest follow site. To describe the phase transition, the modified KdV equation near the critical point is derived by using the reductive perturbation method, with obtaining the dependence of the propagation kink solution for traffic jams on the traffic current cooperation among three consecutive sites. The direct numerical are conducted to verify the results of theoretical analysis, and explore the effects of the traffic current cooperation on the traffic flux of the vehicle flow system.

  13. HUG sets up an emergency operations centre on the CERN site

    CERN Multimedia

    Antonella Del Rosso

    2015-01-01

    Discussions between CERN and the Hôpitaux universitaires de Genève (HUG), under the aegis of the Swiss authorities, have resulted in the setting-up of an emergency operations centre on the CERN site. This will be the operations base for an emergency doctor, a medical emergency vehicle and a driver. Located on the Swiss part of the Meyrin site, close to Building 57, it will be inaugurated on 20 May.   SMUR team based at CERN. CERN’s medical staff and fire-fighters dispense first aid but in medical emergencies they are obliged to call on outside services to treat and transfer patients to hospital. In the Canton of Geneva, this service is provided by HUG via the 144 emergency line. But HUG is based on the eastern side of Geneva, a long way from CERN, and response times can be substantial. In order to improve the safety of the growing number of people on the site, CERN asked Switzerland, as one of its Host States, to help it reduce the medical emergency response t...

  14. DOE/KEURP Site Operator Program year 5 first quarter report, July 1-- September 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy` s Electric Vehicle Site Operator Program. Through participation in this program, Kansas State is displaying, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU now has two electric cars. Both are electric conversion vehicles from Soleq Corporation out of Chicago. KSU in conjunction with KEURP also initiated procurement for the purchase of four (4) Chevy S-10 pickup trucks. Since the supplier, GE-Spartan, canceled its effort concerning the production of vehicles other appropriate sources were sought. Today, K-State and the Kansas Utilities are working with Troy Design and Manufacturing (TDM), Redford, Michigan. TDM is working with Ford Motor Company and expects to become the first certified electric vehicle Quality Vehicle Modifier (QVM). Kansas State has entered into an agreement to assist TDM in supporting the infrastructure and technical manual development for these vehicles. The Soleq EVcorts have not been signed to illustrate to the public that it is an electric vehicle. Magnetic signs have been made for special functions to ensure sponsor support is recognized and acknowledged. As soon as TDM`s Ford Ranger electric vehicles are delivered they will be used throughout the state by utility companies that are participating with K-State`s Site Operator Program.

  15. Site Environmental Report for Calendar Year 2003 DOE Operations at The Boeing Company, Rocketdyne Propulsion & Power

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (US). Rocketdyne Propulsion and Power; Rutherford, Phil [The Boeing Company, Canoga Park, CA (US). Rocketdyne Propulsion and Power; Samuels, Sandy [The Boeing Company, Canoga Park, CA (US). Rocketdyne Propulsion and Power; Lee, Majelle [The Boeing Company, Canoga Park, CA (US). Rocketdyne Propulsion and Power

    2004-09-30

    This Annual Site Environmental Report (ASER) for 2003 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing Rocketdyne’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations at ETEC included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities at ETEC involved the operation of large-scale liquid metal facilities that were used for testing liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2003 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  16. Summary of operations and performance of the Murdock site restoration project in June 2005-December 2006.

    Energy Technology Data Exchange (ETDEWEB)

    LaFreniere, L. M.; Environmental Science Division

    2007-05-31

    This document summarizes the performance of the groundwater and surface water restoration systems installed by the Commodity Credit Corporation of the U.S. Department of Agriculture (CCC/USDA) at the former CCC/USDA grain storage facility in Murdock, Nebraska, during the initial period of systems operation, from June 2005 through December 2006. In the Murdock project, several innovative technologies are being used to remove carbon tetrachloride contamination from a shallow aquifer underlying the town, as well as from water naturally discharged to the surface at the headwaters of a small creek (a tributary to Pawnee Creek) north of the town (Figure 1.1). The restoration activities at Murdock are being conducted by the CCC/USDA as a non-time-critical removal action under the regulatory authority and supervision of the U.S. Environmental Protection Agency (EPA), Region VII. Argonne National Laboratory assisted the CCC/USDA by providing technical oversight for the restoration effort and facilities during this review period. Included in this report are the results of all sampling and monitoring activities performed in accord with the EPA-approved Monitoring Plan for this site (Argonne 2006), as well as additional investigative activities conducted during the review period. This document presents overviews of the treatment facilities (Section 2) and site operations and activities (Section 3), then describes the groundwater, surface water, vegetation, and atmospheric monitoring results (Section 4) and modifications and costs during the review period (Section 5). Section 6 summarizes the initial period of operation.

  17. DOE/KEURP Site Operator Program year 5 first quarter report, July 1-- September 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy` s Electric Vehicle Site Operator Program. Through participation in this program, Kansas State is displaying, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU now has two electric cars. Both are electric conversion vehicles from Soleq Corporation out of Chicago. KSU in conjunction with KEURP also initiated procurement for the purchase of four (4) Chevy S-10 pickup trucks. Since the supplier, GE-Spartan, canceled its effort concerning the production of vehicles other appropriate sources were sought. Today, K-State and the Kansas Utilities are working with Troy Design and Manufacturing (TDM), Redford, Michigan. TDM is working with Ford Motor Company and expects to become the first certified electric vehicle Quality Vehicle Modifier (QVM). Kansas State has entered into an agreement to assist TDM in supporting the infrastructure and technical manual development for these vehicles. The Soleq EVcorts have not been signed to illustrate to the public that it is an electric vehicle. Magnetic signs have been made for special functions to ensure sponsor support is recognized and acknowledged. As soon as TDM`s Ford Ranger electric vehicles are delivered they will be used throughout the state by utility companies that are participating with K-State`s Site Operator Program.

  18. Department of Energy Site Operator Program. Final report, October 1, 1991--September 31, 1996

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-31

    York Technical College is a two-year public institution accredited by the Commission of Colleges of the Southern Association of Colleges and Schools. York Technical College has been involved with electric vehicles since the late 1980`s. The four major objectives of the Site Operator Program were (1) field test and evaluate electric and hybrid vehicles and related components; (2) define and develop a national infrastructure system including electric charging systems, service/training education programs, utility system impacts and safety standards; (3) increase public awareness regarding environmental benefits, reduced dependency on foreign oil, technology development, and economic impacts; (4) assist local, state and federal agencies and fleet operators in developing electric and hybrid vehicle programs. The primary thrusts of the electric vehicle program at York Technical College, supporting the objectives of the Site Operator program were: (1) public awareness, (2) public education, (3) EV maintenance curriculum development and maintenance training, (4) field data collection, (5) vehicle modification and upgrade, (6) establish electric vehicle partnerships.

  19. Power lateral pnp transistor operating with high current density in irradiated voltage regulator

    Directory of Open Access Journals (Sweden)

    Vukić Vladimir Đ.

    2013-01-01

    Full Text Available The operation of power lateral pnp transistors in gamma radiation field was examined by detection of the minimum dropout voltage on heavily loaded low-dropout voltage regulators LM2940CT5, clearly demonstrating their low radiation hardness, with unacceptably low values of output voltage and collector-emitter voltage volatility. In conjunction with previous results on base current and forward emitter current gain of serial transistors, it was possible to determine the positive influence of high load current on a slight improvement of voltage regulator LM2940CT5 radiation hardness. The high-current flow through the wide emitter aluminum contact of the serial transistor above the isolation oxide caused intensive annealing of the positive oxide-trapped charge, leading to decrease of the lateral pnp transistor's current gain, but also a more intensive recovery of the small-signal npn transistors in the control circuit. The high current density in the base area of the lateral pnp transistor immediately below the isolation oxide decreased the concentration of negative interface traps. Consequently, the positive influence of the reduced concentration of the oxide-trapped charge on the negative feedback reaction circuit, together with the favourable effect of reduced interface traps concentration, exceeded negative influence of the annealed oxide-trapped charge on the serial pnp transistor's forward emitter current gain.

  20. Analysis of 2016 Meteorological Data from the Knolls Atomic Power Laboratory and Kesselring Site Operations Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Aluzzi, F. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2017-03-16

    Both the Knolls Atomic Power Laboratory (KAPL) in Schenectady, N.Y. and the Kesselring Site Operations (KSO) facility near Ballston Spa, N.Y. are required to estimate the effects of hypothetical emissions of radiological material from their respective facilities by the U.S. Environmental Protection Agency (EPA), which regulates both sites. An atmospheric dispersion model known as CAP88, which was developed and approved by the EPA for such purposes, is used by KAPL and KSO to meet this requirement. CAP88 calculations over a given time period are based on statistical data on the meteorological conditions for that period. Both KAPL and KSO have on-site meteorological towers which take atmospheric measurements at a frequency ideal for EPA regulatory model input. However, an independent analysis and processing of the meteorological data from each tower is required to derive a data set appropriate for use in the CAP88 model. The National Atmospheric Release Advisory Center (NARAC) was contracted to process the meteorological tower data for the 2016 calendar year from both on-site meteorological towers.

  1. Analysis of 2015 Meteorological Data from the Knolls Atomic Power Laboratory and Kesselring Site Operations Facilities

    Energy Technology Data Exchange (ETDEWEB)

    Aluzzi, F. J. [Lawrence Livermore National Lab. (LLNL), Livermore, CA (United States)

    2016-02-19

    Both the Knolls Atomic Power Laboratory (KAPL) in Schenectady, N.Y. and the Kesselring Site Operations (KSO) facility near Ballston Spa, N.Y. are required to estimate the effects of hypothetical emissions of radiological material from their respective facilities by the U.S. Environmental Protection Agency (EPA), which regulates both sites. An atmospheric dispersion model known as CAP88, which was developed and approved by the EPA for such purposes, is used by KAPL and KSO to meet this requirement. CAP88 calculations over a given time period are based on statistical data on the meteorological conditions for that period. Both KAPL and KSO have on-site meteorological towers which take atmospheric measurements at a frequency ideal for EPA regulatory model input. However, an independent analysis and processing of the meteorological data from each tower is required to derive a data set appropriate for use in the CAP88 model. The National Atmospheric Release Advisory Center (NARAC) was contracted to process the meteorological tower data for the 2015 calendar year from both on-site meteorological towers.

  2. How to target inter-regional phase synchronization with dual-site Transcranial Alternating Current Stimulation

    DEFF Research Database (Denmark)

    Saturnino, Guilherme Bicalho; Madsen, Kristoffer Hougaard; Siebner, Hartwig Roman

    2017-01-01

    Large-scale synchronization of neural oscillations is a key mechanism for functional information exchange among brain areas. Dual-site Transcranial Alternating Current Stimulation (ds-TACS) has been recently introduced as non-invasive technique to manipulate the temporal phase relationship of local...... oscillations in two connected cortical areas. While the frequency of ds-TACS is matched, the phase of stimulation is either identical (in-phase stimulation) or opposite (anti-phase stimulation) in the two cortical target areas. In-phase stimulation is thought to synchronize the endogenous oscillations...... and hereby to improve behavioral performance. Conversely, anti-phase stimulation is thought to desynchronize neural oscillations in the two areas, which is expected to decrease performance. Critically, in- and anti-phase ds-TACS should only differ with respect to temporal phase, while all other stimulation...

  3. Inventory of chemicals used at Hanford Site production plants and support operations (1944-1980)

    Energy Technology Data Exchange (ETDEWEB)

    Klem, M. J.

    1990-04-01

    A complete list of chemicals used in the production facilities and support operations of the US Department of Energy Hanford Site is presented to aid development of plans for characterizing the radioactive liquid chemical wastes stored in the 149 single-shell tanks. The complete chemical list is compared to the list provided by the regulatory agencies to identify hazardous chemicals stored in the single-shell tanks. A reduced list has been developed by others and is used to identify the chemical constituents for analysis in the Waste Characterization Plan for the Hanford Site Single-Shell Tanks. The chemical list is based on chemical process flowsheets, essential material consumption records, letters, reports, and other historical data. 14 refs., 36 tabs.

  4. Current State of Off-Site Manufacturing in Australian and Chinese Residential Construction

    Directory of Open Access Journals (Sweden)

    Malik M. A. Khalfan

    2014-01-01

    Full Text Available Many techniques have been implemented to make construction industry more productive. The key focus is on reduction of total duration, reduction in construction cost, improvements in the quality, achieving more sustainable development, and safer construction sites. One of the techniques, which is emerging in the last two decades, is the use of off-site manufacturing (OSM within the construction industry. Several research projects and industry initiatives have reported the benefits and challenges of implementation of OSM. The focus of this paper is Australian and Chinese residential construction industry and the uptake of the OSM concepts. The paper presents a brief review of the current state of OSM in the last five to seven years with the context of the above-mentioned two countries. The paper concludes that the construction industry, both in Australia and China, needs to start walking the talk with regard to OSM adoption. The paper also highlights some of the research gaps in the OSM area, especially within the housing and residential sector.

  5. Assessment of current mass spectrometric workflows for the quantification of low abundant proteins and phosphorylation sites

    Directory of Open Access Journals (Sweden)

    Manuel Bauer

    2015-12-01

    Full Text Available The data described here provide a systematic performance evaluation of popular data-dependent (DDA and independent (DIA mass spectrometric (MS workflows currently used in quantitative proteomics. We assessed the limits of identification, quantification and detection for each method by analyzing a dilution series of 20 unmodified and 10 phosphorylated synthetic heavy labeled reference peptides, respectively, covering six orders of magnitude in peptide concentration with and without a complex human cell digest background. We found that all methods performed very similarly in the absence of background proteins, however, when analyzing whole cell lysates, targeted methods were at least 5–10 times more sensitive than directed or DDA methods. In particular, higher stage fragmentation (MS3 of the neutral loss peak using a linear ion trap increased dynamic quantification range of some phosphopeptides up to 100-fold. We illustrate the power of this targeted MS3 approach for phosphopeptide monitoring by successfully quantifying 9 phosphorylation sites of the kinetochore and spindle assembly checkpoint component Mad1 over different cell cycle states from non-enriched pull-down samples. The data are associated to the research article ‘Evaluation of data-dependent and data-independent mass spectrometric workflows for sensitive quantification of proteins and phosphorylation sites׳ (Bauer et al., 2014 [1]. The mass spectrometry and the analysis dataset have been deposited to the ProteomeXchange Consortium (http://proteomecentral.proteomexchange.org via the PRIDE partner repository with the dataset identifier PXD000964.

  6. DOE KSU EV Site Operator Program. Year 1, fourth quarter report, April 1--June 30, 1992

    Energy Technology Data Exchange (ETDEWEB)

    Hague, J.R.; Steinert, R.A.; Nissen-Pfrang, T.

    1992-08-01

    Kansas State University, with funding from federal, state, public, and private companies, is participating in the DOE Electric Vehicle Site Operator Program. Kansas State is demonstrating, testing, and evaluating electric of hybrid vehicle technology. This will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one (1) electric or hybrid van and four(4) electric cars during the first two years of this five-year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two (2) Soleq 1992 Ford EVcort station wagons. This quarter`s report describes ongoing public relations activities and meetings as well as presenting performance data for the electric vehicles. (GHH)

  7. Electric Vehicle Site Operator Program. Year 1 third quarter report, January 1, 1992--March 31, 1992

    Energy Technology Data Exchange (ETDEWEB)

    1992-06-01

    Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy`s Electric Vehicle Site Operator Program. Through participation is this program, Kansas State is demonstrating, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one (1) electric or hybrid van and four (4) electric cars during the first two years of this five year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two (2) Soleq 1992 Ford EVcort stationwagons.

  8. Results of operation and current safety performance of nuclear facilities located in the Russian Federation

    Science.gov (United States)

    Kuznetsov, V. M.; Khvostova, M. S.

    2016-12-01

    After the NPP radiation accidents in Russia and Japan, a safety statu of Russian nuclear power plants causes concern. A repeated life time extension of power unit reactor plants, designed at the dawn of the nuclear power engineering in the Soviet Union, power augmentation of the plants to 104-109%, operation of power units in a daily power mode in the range of 100-70-100%, the use of untypical for NPP remixed nuclear fuel without a careful study of the results of its application (at least after two operating periods of the research nuclear installations), the aging of operating personnel, and many other management actions of the State Corporation "Rosatom", should attract the attention of the Federal Service for Ecological, Technical and Atomic Supervision (RosTekhNadzor), but this doesn't happen. The paper considers safety issues of nuclear power plants operating in the Russian Federation. The authors collected statistical information on violations in NPP operation over the past 25 years, which shows that even after repeated relaxation over this period of time of safety regulation requirements in nuclear industry and highly expensive NPP modernization, the latter have not become more safe, and the statistics confirms this. At a lower utilization factor high-power pressure-tube reactors RBMK-1000, compared to light water reactors VVER-440 and 1000, have a greater number of violations and that after annual overhauls. A number of direct and root causes of NPP mulfunctions is still high and remains stable for decades. The paper reveals bottlenecks in ensuring nuclear and radiation safety of nuclear facilities. Main outstanding issues on the storage of spent nuclear fuel are defined. Information on emissions and discharges of radioactive substances, as well as fullness of storages of solid and liquid radioactive waste, located at the NPP sites are presented. Russian NPPs stress test results are submitted, as well as data on the coming removal from operation of NPP

  9. Concurrent operational modes and enhanced current sensitivity in heterostructure of magnetoelectric ring and piezoelectric transformer

    Science.gov (United States)

    Zhang, Shengyao; Ming Leung, Chung; Kuang, Wei; Wing Or, Siu; Ho, S. L.

    2013-05-01

    A heterostructure possessing two concurrent operational modes: current sensing (CS) mode and current transduction (CT) mode and an enhanced current sensitivity associated with the CT mode is proposed by combining a magnetoelectric ring (MER) with a piezoelectric transformer (PET). The MER is a ring-shaped magnetoelectric laminate having an axially polarized Pb(Zr, Ti)O3 (PZT) piezoelectric ceramic ring sandwiched between two circumferentially magnetized, inter-magnetically biased Tb0.3Dy0.7Fe1.92 (Terfenol-D) short-fiber/NdFeB magnet/epoxy three-phase magnetostrictive composite rings, while the PET is a Rosen-type PZT piezoelectric ceramic transformer. The current sensitivity (SI) and magnetoelectric voltage coefficient (αV) of the heterostructure in the two operational modes are evaluated theoretically and experimentally. The CS mode provides a large SI of ˜10 mV/A over a flat frequency range of 10 Hz-40 kHz with a high resonance SI of 157 mV/A at 62 kHz. The CT mode gives a 6.4-times enhancement in resonance SI, reaching 1000 mV/A at 62 kHz, as a result of the amplified vortex magnetoelectric effect caused by the vortex magnetoelectric effect in the MER, the matching of the resonance frequencies between the MER and the PET, and the resonance voltage step-up effect in the PET.

  10. Development of a high average current polarized electron source with long cathode operational lifetime

    Energy Technology Data Exchange (ETDEWEB)

    C. K. Sinclair; P. A. Adderley; B. M. Dunham; J. C. Hansknecht; P. Hartmann; M. Poelker; J. S. Price; P. M. Rutt; W. J. Schneider; M. Steigerwald

    2007-02-01

    Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2?105???C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  11. New active-only grounded inductance simulator employing current-mode approach suitable for wide band operation

    Science.gov (United States)

    Yamacli, Serhan; Ozcan, Sadri; Kuntman, Hakan

    2011-08-01

    In this paper, an active-only grounded lossless inductance simulator operating in current-mode is presented. The circuit uses only a current operational amplifier (COA) and an operational transconductance amplifier (OTA). The novelty of the proposed circuit is that it uses a COA instead of a voltage operational amplifier (VOA) to take the wider frequency operation advantage of the current-mode approach. The simulation results obtained through SPICE with 0.5 μm standard CMOS technology verify that the designed circuit can be operated up to 30 MHz, which is much higher than the operation frequency of previously reported inductance simulators utilising VOAs. The inductance value of the presented circuit can be adjusted electronically between 3.9 μH and 37 μH via the biasing current of the OTA. A parallel resonance circuit application is also given validating the operation of the proposed inductance simulator.

  12. Application for a Permit to Operate a Class III Solid Waste Disposal Site at the Nevada National Security Site Area 5 Asbestiform Low-Level Solid Waste Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Programs

    2010-10-04

    The Nevada National Security Site (NNSS) is located approximately 105 km (65 mi) northwest of Las Vegas, Nevada. The U.S. Department of Energy National Nuclear Security Administration Nevada Site Office (NNSA/NSO) is the federal lands management authority for the NNSS and National Security Technologies, LLC (NSTec) is the Management and Operations contractor. Access on and off the NNSS is tightly controlled, restricted, and guarded on a 24-hour basis. The NNSS is posted with signs along its entire perimeter. NSTec is the operator of all solid waste disposal sites on the NNSS. The Area 5 Radioactive Waste Management Site (RWMS) is the location of the permitted facility for the Solid Waste Disposal Site (SWDS). The Area 5 RWMS is located near the eastern edge of the NNSS (Figure 1), approximately 26 km (16 mi) north of Mercury, Nevada. The Area 5 RWMS is used for the disposal of low-level waste (LLW) and mixed low-level waste. Many areas surrounding the RWMS have been used in conducting nuclear tests. The site will be used for the disposal of regulated Asbestiform Low-Level Waste (ALLW), small quantities of low-level radioactive hydrocarbon-burdened (LLHB) media and debris, LLW, LLW that contains Polychlorinated Biphenyl (PCB) Bulk Product Waste greater than 50 ppm that leaches at a rate of less than 10 micrograms of PCB per liter of water, and small quantities of LLHB demolition and construction waste (hereafter called permissible waste). Waste containing free liquids, or waste that is regulated as hazardous waste under the Resource Conservation and Recovery Act (RCRA) or state-of-generation hazardous waste regulations, will not be accepted for disposal at the site. Waste regulated under the Toxic Substances Control Act (TSCA) that will be accepted at the disposal site is regulated asbestos-containing materials (RACM) and PCB Bulk Product Waste greater than 50 ppm that leaches at a rate of less than 10 micrograms of PCB per liter of water. The term asbestiform is

  13. Steady-state and non-steady state operation of counter-current chromatography devices.

    Science.gov (United States)

    Kostanyan, Artak E; Ignatova, Svetlana N; Sutherland, Ian A; Hewitson, Peter; Zakhodjaeva, Yulya A; Erastov, Andrey A

    2013-11-01

    Different variants of separation processes based on steady-state (continuous sample loading) and non-steady state (batch) operating modes of CCC columns have been analyzed and compared. The analysis is carried out on the basis of the modified equilibrium cell model, which takes into account both mechanisms of band broadening - interphase mass transfer and axial mixing. A full theoretical treatment of the intermittent counter-current chromatography with short sample loading time is performed. Analytical expressions are presented allowing the simulation of the intermittent counter-current chromatography separations for various experimental conditions. Chromatographic and extraction separations have been compared and advantages and disadvantages of the two methods have been evaluated. Further technical development of the CCC machines to implement counter-current extraction separations is considered.

  14. NASA's Beachside Corrosion Test Site and Current Environmentally Friendly Corrosion Control Initiatives

    Science.gov (United States)

    Russell, Richard W.; Calle, Luz Marina; Johnston, Frederick; Montgomery, Eliza L.; Curran, Jerome P.; Kolody, Mark R.

    2013-01-01

    NASA began corrosion studies at the Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term corrosion protective coatings for carbon steel. KSC's Beachside Corrosion Test Site (BCTS), which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring, environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acid ic exhaust from the solid rocket boosters. In the years that followed, numerous studies have identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosive environment at the launch pad. This paper presents a historical overview of over 45 years of corrosion and coating evaluation studies and a description of the BCTS's current capabilities. Additionally, current research and testing programs involving chromium free coatings, environmentally friendly corrosion preventative compounds, and alternates to nitric acid passivation will be discussed.

  15. Site Environmental Report for Calendar Year 2005. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    None

    2006-09-30

    This annual report describes the environmental monitoring programs related to the Department of Energy’s (DOE) activities at the Santa Susana Field Laboratory (SSFL) facility located in Ventura County, California during 2005. Part of the SSFL facility, known as Area IV, had been used for DOE’s activities since the 1950s. A broad range of energy related research and development (R&D) projects, including nuclear technologies projects, was conducted at the site. All the nuclear R&D operations in Area IV ceased in 1988. Current efforts are directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and closure of facilities used for liquid metal research.

  16. Residual magnetic field profiles and their current density profiles of coated conductors for fast and slow cut-off current operations

    Energy Technology Data Exchange (ETDEWEB)

    Sun, J.; Taillouli, M.; Hamabe, M.; Watanabe, H.; Chikumoto, N.; Yamaguchi, S. [Chubu University, Kasugai, Aichi (Japan); Shyshkin, O. [V. N. Karazin Kharkiv National University, Kharkov (Ukraine)

    2015-03-15

    Coated conductor is an important candidate for power cable applications due to its high current density. Even for DC power cable transmission, we must study the transport properties of HTS tapes after slow and fast discharge. In order to evaluate relation of the magnetic field with applied current we developed a scanning magnetic field measurements system by employing a Hall probe. This work presents the measurements of the magnetic fields above a coated conductor by varying applied current pattern. In the work, a transport current of 100 A, less than the critical current, is applied to YBCO coated conductor. We measured the residual magnetic field distributions after cut off the transport current with slow and fast operations. The results show differences of the magnetic field profiles and the corresponding current profiles by an inverse solution from the magnetic field measurement between these two operations because of the hysteresis of coated conductor excited by the transport current.

  17. Intra-operative multi-site stimulation: Expanding methodology for cortical brain mapping of language functions.

    Science.gov (United States)

    Gonen, Tal; Gazit, Tomer; Korn, Akiva; Kirschner, Adi; Perry, Daniella; Hendler, Talma; Ram, Zvi

    2017-01-01

    Direct cortical stimulation (DCS) is considered the gold-standard for functional cortical mapping during awake surgery for brain tumor resection. DCS is performed by stimulating one local cortical area at a time. We present a feasibility study using an intra-operative technique aimed at improving our ability to map brain functions which rely on activity in distributed cortical regions. Following standard DCS, Multi-Site Stimulation (MSS) was performed in 15 patients by applying simultaneous cortical stimulations at multiple locations. Language functioning was chosen as a case-cognitive domain due to its relatively well-known cortical organization. MSS, performed at sites that did not produce disruption when applied in a single stimulation point, revealed additional language dysfunction in 73% of the patients. Functional regions identified by this technique were presumed to be significant to language circuitry and were spared during surgery. No new neurological deficits were observed in any of the patients following surgery. Though the neuro-electrical effects of MSS need further investigation, this feasibility study may provide a first step towards sophistication of intra-operative cortical mapping.

  18. Rosetta lander Philae: Flight Dynamics analyses for landing site selection and post-landing operations

    Science.gov (United States)

    Jurado, Eric; Martin, Thierry; Canalias, Elisabet; Blazquez, Alejandro; Garmier, Romain; Ceolin, Thierry; Gaudon, Philippe; Delmas, Cedric; Biele, Jens; Ulamec, Stephan; Remetean, Emile; Torres, Alex; Laurent-Varin, Julien; Dolives, Benoit; Herique, Alain; Rogez, Yves; Kofman, Wlodek; Jorda, Laurent; Zakharov, Vladimir; Crifo, Jean-François; Rodionov, Alexander; Heinish, P.; Vincent, Jean-Baptiste

    2016-08-01

    On the 12th of November 2014, The Rosetta Lander Philae became the first spacecraft to softly land on a comet nucleus. Due to the double failure of the cold gas hold-down thruster and the anchoring harpoons that should have fixed Philae to the surface, it spent approximately two hours bouncing over the comet surface to finally come at rest one km away from its target site. Nevertheless it was operated during the 57 h of its First Science Sequence. The FSS, performed with the two batteries, should have been followed by the Long Term Science Sequence but Philae was in a place not well illuminated and fell into hibernation. Yet, thanks to reducing distance to the Sun and to seasonal effect, it woke up at end of April and on 13th of June it contacted Rosetta again. To achieve this successful landing, an intense preparation work had been carried out mainly between August and November 2014 to select the targeted landing site and define the final landing trajectory. After the landing, the data collected during on-comet operations have been used to assess the final position and orientation of Philae, and to prepare the wake-up. This paper addresses the Flight Dynamics studies done in the scope of this landing preparation from Lander side, in close cooperation with the team at ESA, responsible for Rosetta, as well as for the reconstruction of the bouncing trajectory and orientation of the Lander after touchdown.

  19. Operational Implementation of the MARSSIM Process at the Wayne Interim Storage Site

    Energy Technology Data Exchange (ETDEWEB)

    Hays, D. C. Jr.; Trujillo, P. A. IV.; Zoller, S. G.

    2002-02-27

    This paper describes the methodologies behind the operational implementation of the Multi Agency Radiation Site Survey and Investigation Manual (MARSSIM) process at the Wayne Interim Storage Site (WISS). The United States Army Corps of Engineers (USACE) and Environmental Chemical Corporation (ECC) have implemented the MARSSIM process using various surveys producing raw data. The final remedial status of a survey unit is derived through data reduction, while maintaining a high degree of efficiency in the construction aspects of the remedial action. Data reduction of field measurements is accomplished by merging the data outputs of a Digital Global Positioning System, an exposure rate meter, and laboratory analyses to produce maps which present exposure rates, elevations, survey unit boundaries, direct measurement locations, and sampling locations on a single map. The map serves as a data-posting plot and allows the project team to easily judge the survey unit's remedial status. The operational implementation of the MARSSIM process has been successful in determining the eligibility of survey units for final status surveys at the WISS and also in demonstrating final status radiological and chemical conditions while maintaining an efficient remedial action effort.

  20. A current to voltage converter for cryogenics using a CMOS operational amplifier

    Energy Technology Data Exchange (ETDEWEB)

    Hayashi, K; Saitoh, K; Shibayama, Y; Shirahama, K [Department of Physics, Keio University, Yokohama 223-8522 (Japan)], E-mail: khayashi@a2.keio.jp

    2009-02-01

    We have constructed a versatile current to voltage (I-V) converter operating at liquid helium temperature, using a commercially available all-CMOS OPamp. It is valuable for cryogenic measurements of electrical current of nano-pico amperes, for example, in scanning probe microscopy. The I-V converter is thermally linked to liquid helium bath and self-heated up to 10.7 K. We have confirmed its capability of a transimpedance gain of 10{sup 6} V/A and a bandwidth from DC to 200 kHz. In order to test the practical use for a frequency-modulation atomic force microscope, we have measured the resonance frequency shift of a quartz tuning fork at 32 kHz. In the operation of the I-V converter close to the sensor at liquid helium temperature, the signal-to-noise ratio has been improved to a factor of 13.6 compared to the operation at room temperature.

  1. Operational Experience and Consolidations for the Current Lead Control Valves of the Large Hadron Collider

    CERN Document Server

    Perin, A; Pirotte, O; Krieger, B; Widmer, A

    2012-01-01

    The Large Hadron Collider superconducting magnets are powered by more than 1400 gas cooled current leads ranging from 120 A to 13000 A. The gas flow required by the leads is controlled by solenoid proportional valves with dimensions from DN 1.8 mm to DN 10 mm. During the first months of operation, signs of premature wear were found in the active parts of the valves. This created major problems for the functioning of the current leads threatening the availability of the LHC. Following the detection of the problems, a series of measures were implemented to keep the LHC running, to launch a development program to solve the premature wear problem and to prepare for a global consolidation of the gas flow control system. This article describes first the difficulties encountered and the measures taken to ensure a continuous operation of the LHC during the first year of operation. The development of new friction free valves is then presented along with the consolidation program and the test equipment developed to val...

  2. MOSE: A Demonstrator for an Automatic Operational System for the Optical Turbulence Forecast for ESO Sites

    Science.gov (United States)

    Masciadri, Elena; Lascaux, F.; Turchi, A.; Fini, L.

    2017-09-01

    "Most of the observations performed with new-generation ground-based telescopes are employing the Service Mode. To optimize the flexible-scheduling of scientific programs and instruments, the optical turbulence (OT) forecast is a must, particularly when observations are supported by adaptive optics (AO) and Interferometry. Reliable OT forecast are crucial to optimize the usage of AO and interferometric facilities which is not possible when using only optical measurements. Numerical techniques are the best placed to achieve such a goal. The MOSE project (MOdeling ESO Sites), co-funded by ESO, aimed at proving the feasibility of the forecast of (1) all the classical atmospheric parameters (such as temperature, wind speed and direction, relative humidity) and (2) the optical turbulence i.e. the CN 2 profiles and all the main integrated astro-climatic parameters derived from the CN 2 (the seeing, the isoplanatic angle, the wavefront coherence time) above the two ESO sites of Cerro Paranal and Cerro Armazones. The proposed technique is based on the use of a non-hydrostatic atmospheric meso-scale model and a dedicated code for the optical turbulence. The final goal of the project aimed at implementing an automatic system for the operational forecasts of the aforementioned parameters to support the astronomical observations above the two sites. MOSE Phase A and B have been completed and a set of dedicated papers have been published on the topic. Model performances have been extensively quantified with several dedicated figures of merit and we proved that our tool is able to provide reliable forecasts of optical turbulence and atmospheric parameters with very satisfactory score of success. This should guarantee us to make a step ahead in the framework of the Service Mode of new generation telescopes. A conceptual design as well as an operational plan of the automatic system has been submitted to ESO as integral part of the feasibility study. We completed a negotiation with

  3. Atmospheric CO sub 2 concentrations derived from flask samples collected at USSR-operated sampling sites

    Energy Technology Data Exchange (ETDEWEB)

    Boden, T.A. (comp.) (Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center); Brounshtein, A.M.; Faber, E.V.; Shashkov, A.A. (Glavnaya Geofizicheskaya Observatoriya, St. Petersburg (USSR))

    1991-12-01

    This document presents daily atmospheric CO{sub 2} concentrations from four USSR-operated sampling sites (Teriberka Station, Ocean Station Charlie, Bering Island, and Kotelny Island). The period of record varies by station with the earliest measurements dating back to 1983 and recent estimates from early 1991. These CO{sub 2} concentrations are derived from air samples collected in 1.5-L stainless steel electropolished flasks and later analyzed at the Main Geophysical Observatory (St. Petersburg, USSR) using a nondispersive infrared gas analyzer. Measurements not meeting wind direction, wind speed, inter-flask agreement, and climate condition criteria were either discarded or flagged. All measurements have been corrected for drift biases introduced during flask storage. These atmospheric CO{sub 2} concentrations are considered indicative of regional background air conditions and are directly traceable to the World Meteorological Organization's primary CO{sub 2} standards. These measurements support the rising trend in atmospheric CO{sub 2} concentrations measured at other monitoring sites around the world and may be compared with similar measurements made by various monitoring programs at other northern latitude sites. The document presents the atmospheric CO{sub 2} concentrations in graphical and tabular form, describes the sampling methods, defines limitations and restrictions of the data, and describes the information on the magnetic media.

  4. Electromagnetic Structure of A=2 and 3 Nuclei and the Nuclear Current Operator

    Energy Technology Data Exchange (ETDEWEB)

    Rocco Schiavilla

    2005-02-01

    Different models for conserved two- and three-body electromagnetic currents are constructed from two- and three-nucleon interactions, using either meson-exchange mechanisms or minimal substitution in the momentum dependence of these interactions. The connection between these two different schemes is elucidated. A number of low-energy electronuclear observables, including (i) np radiative capture at thermal neutron energies and deuteron photodisintegration at low energies, (ii) nd and pd radiative capture reactions, and (iii) isoscalar and isovector magnetic form factors of {sup 3}H and {sup 3}He, are calculated in order to make a comparative study of these models for the current operator. The realistic Argonne v{sub 18} two-nucleon and Urbana IX or Tucson-Melbourne three-nucleon interactions are taken as a case study. For A=3 processes, the bound and continuum wave functions, both below and above deuteron breakup threshold, are obtained with the correlated hyperspherical-harmonics method. Three-body currents give small but significant contributions to some of the polarization observables in the {sup 2}H(p,{gamma}){sup 3}He process and the {sup 2}H(n,{gamma}){sup 3}H cross section at thermal neutron energies. It is shown that the use of a current which did not exactly satisfy current conservation with the two- and three-nucleon interactions in the Hamiltonian was responsible for some of the discrepancies reported in previous studies between the experimental and theoretical polarization observables in pd radiative capture.

  5. A HIGH PERFORMANCE FULLY DIFFERENTIAL PURE CURRENT MODE OPERATIONAL AMPLIFIER AND ITS APPLICATIONS

    Directory of Open Access Journals (Sweden)

    SEYED JAVAD AZHARI

    2012-08-01

    Full Text Available In this paper a novel high performance all current-mode fully-differential (FD Current mode Operational Amplifier (COA in BIPOLAR technology is presented. The unique true current mode simple structure grants the proposed COA the largest yet reported unity gain frequency while providing low voltage low power operation. Benefiting from some novel ideas, it also exhibits high gain, high common mode rejection ratio (CMRR, high power supply rejection ratio (PSRR, high output impedance, low input impedance and most importantly high current drive capability. Its most important parameters are derived and its performance is proved by PSPICE simulations using 0.8 μm BICMOS process parameters at supply voltage of ±1.2V indicating the values of 82.4 dB,52.3º, 31.5 Ω, 31.78 MΩ, 179.2 dB, 2 mW and 698 MHz for gain, phase margin, input impedance, output impedance, CMRR, power and unity gain frequency respectively. Its CMRR also shows very high frequency of 2.64 GHz at zero dB. Its very high PSRR+/PSRR- of 182 dB/196 dB makes the proposed COA a highly suitable block in Mixed-Mode (SOC chips. Most favourably it can deliver up to ±1.5 mA yielding a high current drive capability exceeding 25. To demonstrate the performance of the proposed COA, it is used to realize a constant bandwidth voltage amplifier and a high performance Rm amplifier.

  6. Current Conditions Risk Assessment for the 300-FF-5 Groundwater Operable Unit

    Energy Technology Data Exchange (ETDEWEB)

    Miley, Terri B.; Bunn, Amoret L.; Napier, Bruce A.; Peterson, Robert E.; Becker, James M.

    2007-11-01

    This report updates a baseline risk assessment for the 300 Area prepared in 1994. The update includes consideration of changes in contaminants of interest and in the environment that have occurred during the period of interim remedial action, i.e., 1996 to the present, as well as the sub-regions, for which no initial risk assessments have been conducted. In 1996, a record of decision (ROD) stipulated interim remedial action for groundwater affected by releases from 300 Area sources, as follows: (a) continued monitoring of groundwater that is contaminated above health-based levels to ensure that concentrations continue to decrease, and (b) institutional controls to ensure that groundwater use is restricted to prevent unacceptable exposure to groundwater contamination. In 2000, the groundwater beneath the two outlying sub-regions was added to the operable unit. In 2001, the first 5-year review of the ROD found that the interim remedy and remedial action objectives were still appropriate, although the review called for additional characterization activities. This report includes a current conditions baseline ecological and human health risk assessment using maximum concentrations in the environmental media of the 300-FF-5 Operable Unit and downstream conditions at the City of Richland, Washington. The scope for this assessment includes only current measured environmental concentrations and current use scenarios. Future environmental concentrations and future land uses are not considered in this assessment.

  7. Observation of self-magnetic field relaxations in Bi2223 and Y123 HTS tapes after over-current pulse and DC current operation

    Science.gov (United States)

    Tallouli, M.; Sun, J.; Chikumoto, N.; Otabe, E. S.; Shyshkin, O.; Charfi-Kaddour, S.; Yamaguchi, S.

    2016-07-01

    The development of power transmission lines based on long-length HTS tapes requires the production of high quality tapes. Due to fault conditions, technical mistakes and human errors during the operation of a DC power transmission line, an over-current pulse, several times larger than the rated current, could occur. To study the effect of such over-current pulses on the transport current density distribution in the HTS tapes, we simulated two start-up scenarios for one BSCCO and two YBCO tapes. The first start-up scenario is an initial over-current pulse during which the transport current was turned on rapidly, rising to 900 A during the first milliseconds, then reduced to a 100 A DC current. The second start-up scenario is normal operation, and involved increasing the transport current slowly from 0 A to 100 A at a rate of 1 A/s. For both scenarios, we then measured the vertical component of the self-magnetic field by means of a Hall probe above the tape, and afterward, by solving a linear equation of the inverse problem we obtain the current density profiles. We observe a change of the self-magnetic field above the edge of the BSCCO and YBCO tapes during 30 min after the 5 ms of over-current pulse and during the normal operation. The current density profiles are peaked in the centre for over-current pulse, and more peaked around the edge of the HTS tape for normal operation, which means that the limited time over-current pulse changes the current density profiles of the HTS tapes. We observe also a loop of current for YBCO tapes and we show the role of the HTS tape stabilizer.

  8. Biasing, operation and parasitic current limitation in single device equivalent to CMOS, and other semiconductor systems

    Science.gov (United States)

    Welch, James D.

    2003-09-23

    Disclosed are semiconductor devices including at least one junction which is rectifying whether the semiconductor is caused to be N or P-type, by the presence of applied gate voltage field induced carriers in essentially intrinsic, essentially homogeneously simultaneously containing both N and P-type metallurgical dopants at substantially equal doping levels, essentially homogeneously simultaneously containing both N and P-type metallurgical dopants at different doping levels, and containing a single metallurgical doping type, and functional combinations thereof. In particular, inverting and non-inverting gate voltage channel induced semiconductor single devices with operating characteristics similar to conventional multiple device CMOS systems, which can be operated as modulators, are disclosed as are a non-latching SCR and an approach to blocking parasitic currents utilizing material(s) which form rectifying junctions with both N and P-type semiconductor whether metallurigically or field induced.

  9. Environmental restoration and waste management site-specific plan for Richland Operations Office. [Contains glossary

    Energy Technology Data Exchange (ETDEWEB)

    1991-09-01

    This document was prepared to implement and support the US Department of Energy-Headquarters (DOE-HQ) national plan. The national plan, entitled Environmental Restoration and Waste Management Five-Year Plan (DOE 1990b) (hereinafter referred to as the DOE-HQ Five-Year Plan) is the cornerstone of the US Department of Energy's (DOE) long-term strategy in environmental restoration and waste management. The DOE-HQ Five-Year Plan addresses overall philosophy and environmental and waste-related activities under the responsibilities of the DOE Office of Environmental Restoration and Waste Management. The plan also reaffirms DOE-HQ goals to bring its nuclear sites into environmental compliance in cooperation with its regulators and the public, and to clean up and restore the environment by 2019 (the commitment for the Hanford Site is for one year sooner, or 2018). This document is part of the site-specific plan for the US Department of Energy-Richland Operations Office (DOE-RL). It is the first revision of the original plan, which was dated December 1989 (DOE-RL 1989a). This document is a companion document to the Overview of the Hanford Cleanup Five-Year Plan (DOE-RL 1989d) and The Hanford Site Environmental Restoration and Waste Management Five-Year Plan Activity Data Sheets (DOE-RL 1991). Although there are three documents that make up the complete DOE-RL plan, this detailed information volume was prepared so it could be used as a standalone document. 71 refs., 40 figs., 28 tabs.

  10. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode.

    Science.gov (United States)

    Poehlmann, Flavio R; Cappelli, Mark A; Rieker, Gregory B

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  11. Current distribution measurements inside an electromagnetic plasma gun operated in a gas-puff mode

    Science.gov (United States)

    Poehlmann, Flavio R.; Cappelli, Mark A.; Rieker, Gregory B.

    2010-12-01

    Measurements are presented of the time-dependent current distribution inside a coaxial electromagnetic plasma gun. The measurements are carried out using an array of six axially distributed dual-Rogowski coils in a balanced circuit configuration. The radial current distributions indicate that operation in the gas-puff mode, i.e., the mode in which the electrode voltage is applied before injection of the gas, results in a stationary ionization front consistent with the presence of a plasma deflagration. The effects of varying the bank capacitance, transmission line inductance, and applied electrode voltage were studied over the range from 14 to 112 μF, 50 to 200 nH, and 1 to 3 kV, respectively.

  12. Development of a high average current polarized electron source with long cathode operational lifetime

    Directory of Open Access Journals (Sweden)

    C. K. Sinclair

    2007-02-01

    Full Text Available Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2×10^{5}   C/cm^{2} and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  13. Field Measurements at River and Tidal Current Sites for Hydrokinetic Energy Development: Best Practices Manual

    Energy Technology Data Exchange (ETDEWEB)

    Neary, Vincent S [ORNL; Gunawan, Budi [Oak Ridge National Laboratory (ORNL)

    2011-09-01

    In this report, existing data collection techniques and protocols for characterizing open channel flows are reviewed and refined to further address the needs of the MHK industry. The report provides an overview of the hydrodynamics of river and tidal channels, and the working principles of modern acoustic instrumentation, including best practices in remote sensing methods that can be applied to hydrokinetic energy site characterization. Emphasis is placed upon acoustic Doppler velocimeter (ADV) and acoustic-Doppler current profiler (ADCP) instruments, as these represent the most practical and economical tools for use in the MHK industry. Incorporating the best practices as found in the literature, including the parameters to be measured, the instruments to be deployed, the instrument deployment strategy, and data post-processing techniques. The data collected from this procedure aims to inform the hydro-mechanical design of MHK systems with respect to energy generation and structural loading, as well as provide reference hydrodynamics for environmental impact studies. The standard metrics and protocols defined herein can be utilized to guide field experiments with MHK systems.

  14. Operation Tests for SN Transition Superconducting Fault Current Limiter in the Power System Simulator

    Science.gov (United States)

    Kameda, Hideyuki; Torii, Shinji; Kumano, Teruhisa; Sakaki, Hisayoshi; Kubota, Hiroshi; Yasuda, Kenji

    One of important problems to be solved in Japanese trunk transmission systems is the reduction of short circuit capacity. As this countermeasure, double buses are split into two buses in some substations. In recent years, dispersed generators are introduced in lower voltage classes due to the introduction of the electricity deregulation. In such a distribution system as many dispersed generators are introduced, it is a possibility that the fault current becomes beyond the breaking capacity at the occurrence of short circuit. Introduction of superconducting fault current limiters into a power system is very effective as one of the means to solve the above-mentioned problem, and we have studied on the effective introduction method of them and setting method of their parameters. This paper describes the results of the operation tests for SN transition type of a superconducting fault current limiter using 3 phases of FCL modules against various kinds of system faults or inrush current in the Power System Simulator installed at CRIEPI.

  15. Electric and hybrid vehicle program, site operator program quarterly progress report for April through June 1996 (third quarter of fiscal year 1996)

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States); Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Briasco, S. [Los Angeles Dept. of Water and Power, CA (United States)] [and others

    1997-01-01

    The US Department of Energy (DOE) Site Operator Program was initially established to meet the requirements of the Electric and Hybrid Vehicle Research, Development, and Demonstration Act of 1976. The Program has since evolved in response to new legislation and interests. The goals of the Site Operator Program include the field evaluation of electric vehicles (EVs) in real-world applications and environments; the advancement of electric vehicle technologies; the development of infrastructure elements necessary to support significant electric vehicle use; and increasing the awareness and acceptance of EVs by the public. The Site Operator Program currently consists of eleven participants under contract and two other organizations that have data-sharing agreements with the Program (Table ES-1). Several national organizations have joined DOE to further the introduction and awareness of electric vehicles, including: (1) EVAmerica (a utility program) and DOE conduct performance and evaluation tests to support market development for electric vehicles; and (2) DOE, the Department of Transportation, the Electric Transportation Coalition, and the Electric Vehicle Association of the Americas are conducting a series of workshops to encourage urban groups in Clean Cities (a DOE program) to initiate the policies and infrastructure development necessary to support large-scale demonstrations, and ultimately the mass market use, of electric vehicles. The current focus of the Program is the collection and dissemination of EV operations and performance data to aid in the evaluation of real-world EV use. This report contains several sections with vehicle evaluation as a focus.

  16. Electric and hybrid vehicle program, site operator program quarterly progress report for April through June 1996 (third quarter of fiscal year 1996)

    Energy Technology Data Exchange (ETDEWEB)

    Francfort, J. [Lockheed Idaho Technologies Co., Idaho Falls, ID (United States); Bassett, R.R. [Sandia National Labs., Albuquerque, NM (United States); Briasco, S. [Los Angeles Dept. of Water and Power, CA (United States)] [and others

    1997-01-01

    The US Department of Energy (DOE) Site Operator Program was initially established to meet the requirements of the Electric and Hybrid Vehicle Research, Development, and Demonstration Act of 1976. The Program has since evolved in response to new legislation and interests. The goals of the Site Operator Program include the field evaluation of electric vehicles (EVs) in real-world applications and environments; the advancement of electric vehicle technologies; the development of infrastructure elements necessary to support significant electric vehicle use; and increasing the awareness and acceptance of EVs by the public. The Site Operator Program currently consists of eleven participants under contract and two other organizations that have data-sharing agreements with the Program (Table ES-1). Several national organizations have joined DOE to further the introduction and awareness of electric vehicles, including: (1) EVAmerica (a utility program) and DOE conduct performance and evaluation tests to support market development for electric vehicles; and (2) DOE, the Department of Transportation, the Electric Transportation Coalition, and the Electric Vehicle Association of the Americas are conducting a series of workshops to encourage urban groups in Clean Cities (a DOE program) to initiate the policies and infrastructure development necessary to support large-scale demonstrations, and ultimately the mass market use, of electric vehicles. The current focus of the Program is the collection and dissemination of EV operations and performance data to aid in the evaluation of real-world EV use. This report contains several sections with vehicle evaluation as a focus.

  17. Memristive operation mode of a site-controlled quantum dot floating gate transistor

    Energy Technology Data Exchange (ETDEWEB)

    Maier, P., E-mail: patrick.maier@physik.uni-wuerzburg.de; Hartmann, F.; Mauder, T.; Emmerling, M.; Schneider, C.; Kamp, M.; Worschech, L. [Technische Physik, Physikalisches Institut, Wilhelm Conrad Röntgen Research Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); Höfling, S. [Technische Physik, Physikalisches Institut, Wilhelm Conrad Röntgen Research Center for Complex Material Systems, Universität Würzburg, Am Hubland, D-97074 Würzburg (Germany); SUPA, School of Physics and Astronomy, University of St Andrews, St Andrews KY16 9SS (United Kingdom)

    2015-05-18

    We have realized a floating gate transistor based on a GaAs/AlGaAs heterostructure with site-controlled InAs quantum dots. By short-circuiting the source contact with the lateral gates and performing closed voltage sweep cycles, we observe a memristive operation mode with pinched hysteresis loops and two clearly distinguishable conductive states. The conductance depends on the quantum dot charge which can be altered in a controllable manner by the voltage value and time interval spent in the charging region. The quantum dot memristor has the potential to realize artificial synapses in a state-of-the-art opto-electronic semiconductor platform by charge localization and Coulomb coupling.

  18. Operational experience in the use of 18 kA HTS current leads for Edipo

    Science.gov (United States)

    March, S.; Wesche, R.; Bruzzone, P.

    2014-05-01

    In spring 2013, the Edipo facility of CRPP was commissioned. The dipole is powered via two 18 kA HTS current leads, designed and manufactured at CRPP. As part of the Edipo commissioning framework, the operational parameters of the leads were implemented in the control system. The in-situ tests were found to be in good agreement with the tests performed without a background field in 2011. The leads consist of a conduction cooled HTS module, made of AgMgAu/Bi-2223 stacks, and a wire bundle heat exchanger. The heat exchanger is cooled by forced flow helium gas, the inlet temperature of which was measured to vary between 65 K and 85 K. During operation with field, the mass flow rate is a function of current (2.05 g/s per lead at full field, 12.35 T, 17.2 kA). Reduced cooling investigations showed that 0.31 g/s per lead is suitable for overnight standby and 0.2 g/s per lead for longer periods. For detection of and protection against quench in the HTS module, a threshold of 10 mV was found to be appropriate. The heat exchanger has a voltage protection threshold of 120 mV. The temperatures of the heat exchanger, the HTS, and the helium inlet temperature were monitored in order to provide a further layer of protection.

  19. Cost Effective, Ultra Sensitive Groundwater Monitoring for Site Remediation and Management: Standard Operating Procedures with QA/QC

    Science.gov (United States)

    2015-05-01

    GUIDANCE DOCUMENT Cost-Effective, Ultra-Sensitive Groundwater Monitoring for Site Remediation and Management: Standard Operating Procedures... Groundwater Monitoring for Site Remediation and Management 5b. GRANT NUMBER 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR(S) Halden, R.U., Roll, I.B. 5d...DEPLOYMENT WORK As with any groundwater sampling method, the decision to apply the IS2 technology is based on the site characteristics and the type

  20. US Department of Energy Nevada Operations Office annual site environmental report, 1992. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Latham, A.R.; Townsend, Y.E. [eds.

    1993-09-01

    This report contains the environmental monitoring and assessment results for the Nevada Test Site for 1992. Monitoring and surveillance on and around the NTS by DOE contractors and Site user organizations during 1992 indicated that underground nuclear testing operations were conducted in compliance with regulations, i.e., the dose the maximally exposed offsite individual could have received was less than 0.15 percent of the guideline for air exposure. All 1992 nuclear events took place during the first three quarters of the calendar year prior to the Congressional testing moratorium. All discharges of radioactive liquids remained onsite in containment ponds, and there was no indication of potential migration of radioactivity to the offsite area through groundwater. Surveillance around the NTS indicated that airborne radioactivity from test operations was not detectable offsite, and no measurable net exposure to members of the offsite population was detected through the offsite dosimetry program. Using the CAP88-PC model and NTS radionuclide emissions data, the calculated maximum effective dose equivalent offsite would have been 0.012 mrem. Any person receiving this dose was also exposed to 78 mrem from natural background radiation. There were no nonradiological releases to the offsite area. Hazardous wastes were shipped to EPA-approved disposal facilities. Compliance with the various regulations stemming from the National Environmental Policy Act is being achieved and, where mandated, permits for air and water discharges and waste management have been obtained from the appropriate agencies. Non-NTS support facilities complied with the requirements of air quality permits and state or local wastewater discharge and hazardous waste permits.

  1. GROUDWATER REMEDIATION AT THE 100-HR-3 OPERABLE UNIT HANFORD SITE WASHINGTON USA - 11507

    Energy Technology Data Exchange (ETDEWEB)

    SMOOT JL; BIEBESHEIMER FH; ELUSKIE JA; SPILIOTOPOULOS A; TONKIN MJ; SIMPKIN T

    2011-01-12

    The 100-HR-3 Groundwater Operable Unit (OU) at the Hanford Site underlies three former plutonium production reactors and the associated infrastructure at the 100-D and 100-H Areas. The primary contaminant of concern at the site is hexavalent chromium; the secondary contaminants are strontium-90, technetium-99, tritium, uranium, and nitrate. The hexavalent chromium plume is the largest plume of its type in the state of Washington, covering an area of approximately 7 km{sup 2} (2.7 mi{sup 2}) with concentrations greater than 20 {micro}g/L. Concentrations range from 60,000 {micro}g/L near the former dichromate transfer station in the 100-D Area to large areas of 20 to 100 {micro}g/L across much of the plume area. Pump-and-treat operations began in 1997 and continued into 2010 at a limited scale of approximately 200 gal/min. Remediation of groundwater has been fairly successful in reaching remedial action objectives (RAOs) of 20 {micro}g/L over a limited region at the 100-H, but less effective at 100-D. In 2000, an in situ, permeable reactive barrier was installed downgradient of the hotspot in 100-D as a second remedy. The RAOs are still being exceeded over a large portion of the area. The CH2M HILL Plateau Remediation Company was awarded the remediation contract for groundwater in 2008 and initiated a remedial process optimization study consisting of modeling and technical studies intended to enhance the remediation. As a result of the study, 1,400 gal/min of expanded treatment capacity are being implemented. These new systems are designed to meet 2012 and 2020 target milestones for protection of the Columbia River and cleanup of the groundwater plumes.

  2. TECHNICAL EVALUATION OF SOIL REMEDIATION ALTERNATIVES AT THE BUILDING 812 OPERABLE UNIT, LAWRENCE LIVERMORE NATIONAL LABORATORY SITE 300

    Energy Technology Data Exchange (ETDEWEB)

    Eddy-Dilek, C.; Miles, D.; Abitz, R.

    2009-08-14

    The Department of Energy Livermore Site Office requested a technical review of remedial alternatives proposed for the Building 812 Operable Unit, Site 300 at the Lawrence Livermore National Laboratory. The team visited the site and reviewed the alternatives proposed for soil remediation in the draft RI/FS and made the following observations and recommendations. Based on the current information available for the site, the team did not identify a single technology that would be cost effective and/or ecologically sound to remediate DU contamination at Building 812 to current remedial goals. Soil washing is not a viable alternative and should not be considered at the site unless final remediation levels can be negotiated to significantly higher levels. This recommendation is based on the results of soil washing treatability studies at Fernald and Ashtabula that suggest that the technology would only be effective to address final remediation levels higher than 50 pCi/g. The technical review team identified four areas of technical uncertainty that should be resolved before the final selection of a preferred remedial strategy is made. Areas of significant technical uncertainty that should be addressed include: (1) Better delineation of the spatial distribution of surface contamination and the vertical distribution of subsurface contamination in the area of the firing table and associated alluvial deposits; (2) Chemical and physical characterization of residual depleted uranium (DU) at the site; (3) Determination of actual contaminant concentrations in air particulates to support risk modeling; and (4) More realistic estimation of cost for remedial alternatives, including soil washing, that were derived primarily from vendor estimates. Instead of conducting the planned soil washing treatability study, the team recommends that the site consider a new phased approach that combines additional characterization approaches and technologies to address the technical uncertainty in

  3. ALTERNATIVE REMEDIATION TECHNOLOGY STUDY FOR GROUNDWATER TREATMENT AT 200-PO-1 OPERABLE UNIT AT HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    DADO MA

    2008-07-31

    This study focuses on the remediation methods and technologies applicable for use at 200-PO-I Groundwater Operable Unit (OU) at the Hanford Site. The 200-PO-I Groundwater au requires groundwater remediation because of the existence of contaminants of potential concern (COPC). A screening was conducted on alternative technologies and methods of remediation to determine which show the most potential for remediation of groundwater contaminants. The possible technologies were screened to determine which would be suggested for further study and which were not applicable for groundwater remediation. COPCs determined by the Hanford Site groundwater monitoring were grouped into categories based on properties linking them by remediation methods applicable to each COPC group. The screening considered the following criteria. (1) Determine if the suggested method or technology can be used for the specific contaminants found in groundwater and if the technology can be applied at the 200-PO-I Groundwater au, based on physical characteristics such as geology and depth to groundwater. (2) Evaluate screened technologies based on testing and development stages, effectiveness, implementability, cost, and time. This report documents the results of an intern research project conducted by Mathew Dado for Central Plateau Remediation in the Soil and Groundwater Remediation Project. The study was conducted under the technical supervision of Gloria Cummins and management supervision of Theresa Bergman and Becky Austin.

  4. DOE/KEURP site operator program. Year 3, Second Quarter Report, October 1--December 31, 1993

    Energy Technology Data Exchange (ETDEWEB)

    1993-12-31

    Kansas State University, with funding support from federal, state, public, and private companies, is participating in the Department of Energy`s Electric Vehicle Site Operator Program. Through participation in this program, Kansas State is displaying, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU has purchased several electric cars and proposes to purchase additional electric vehicles. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has procured two (2) Soleq 1993 Ford EVcort station wagons. During calendar year 1994, the Kansas` electric vehicle program expects to purchase a minimum of four and a maximum of eleven additional electric vehicles. The G-Van was signed in order for the public to be aware that it was an electric vehicle. Financial participants` names have been stenciled on the back door of the van. The Soleq EvCorts have not been signed. In order to demonstrate the technology as feasible, the EvCorts were deliberately not signed. The goal is to generate a public perception that this vehicle is no different from any similar internal combustion engine vehicle. Magnetic signs have been made for special functions to ensure sponsor support is recognized and acknowledged.

  5. Electric and hybrid vehicle site operators program: Thinking of the future

    Science.gov (United States)

    Kansas State University, with support from federal, state, public, and private companies, is participating in the Department of Energy's Electric Vehicle Site Operator Program. Through participation in this program, Kansas State is displaying, testing, and evaluating electric or hybrid vehicle technology. This participation will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one electric or hybrid van and two electric cars during the first two years of this five-year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two Soleq 1993 Ford EVcort station wagons. The G-Van has been signed in order for the public to be aware that this is an electric drive vehicle. Financial participants' names have been stenciled on the back door of the van. This vehicle is available for short term loan to interested utilities and companies. When other vehicles are obtained, the G-Van will be maintained on K-State's campus.

  6. Superconducting Super Collider site environmental report for calendar year 1991. Pre-operational

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-05-01

    This is the first annual SER prepared for the SSC project. It is a pre-operational report, intended primarily to describe the baseline characterization of the Ellis County, Texas site that has been developed subsequent to the Environmental Impact Statement (EIS) and the Supplemental Environmental impact Statement (SEIS). As such, the emphasis will be on environmental compliance efforts, including monitoring and mitigation programs. The SER also reports on the measures taken to meet the commitments made in the EIS and SEIS. These measures are detailed in the Mitigation Action Plan (MAP) (Department of Energy (DOE), 1991), which was prepared following the signing of the Record of Decision (ROD) to construct the SSC in Texas. The SER will continue to be preoperational until the first high-energy (20 trillion electron volt or TeV) protons collisions are observed, at which point the SSC will become operational. At that time, the SER will place more emphasis on the radiological monitoring program. This SER will report on actions taken in 1991 or earlier and briefly mention some of those planned for calendar year 1992. AU actions completed in 1992 will be addressed in the SER for calendar year 1992.

  7. The operator product expansion between the 16 lowest higher spin currents in the N=4 superspace

    Science.gov (United States)

    Ahn, Changhyun; Kim, Man Hea

    2016-07-01

    Some of the operator product expansions (OPEs) between the lowest 16 higher spin currents of spins (1, 3/2, 3/2, 3/2, 3/2, 2, 2, 2, 2, 2, 2, 5/2, 5/2, 5/2, 5/2, 3) in an extension of the large N=4 linear superconformal algebra were constructed in N=4 superconformal coset SU(5)/SU(3) theory previously. In this paper, by rewriting these OPEs in the N=4 superspace developed by Schoutens (and other groups), the remaining undetermined OPEs in which the corresponding singular terms possess the composite fields with spins s =7/2, 4, 9/2, 5 are completely determined. Furthermore, by introducing arbitrary coefficients in front of the composite fields on the right-hand sides of the above complete 136 OPEs, reexpressing them in the N=2 superspace, and using the N=2 OPEs Mathematica package by Krivonos and Thielemans, the complete structures of the above OPEs with fixed coefficient functions are obtained with the help of various Jacobi identities. We then obtain ten N=2 super OPEs between the four N=2 higher spin currents denoted by (1, 3/2, 3/2, 2), (3/2, 2, 2, 5/2), (3/2, 2, 2, 5/2), and (2, 5/2, 5/2, 3) (corresponding 136 OPEs in the component approach) in the N=4 superconformal coset SU(N+2)/SU(N) theory. Finally, we describe them as one single N=4 super OPE between the above 16 higher spin currents in the N=4 superspace. The fusion rule for this OPE contains the next 16 higher spin currents of spins of (2, 5/2, 5/2, 5/2, 5/2, 3, 3, 3, 3, 3, 3, 7/2, 7/2, 7/2, 7/2, 4) in addition to the quadratic N=4 lowest higher spin multiplet and the large N=4 linear superconformal family of the identity operator. The various structure constants (fixed coefficient functions) appearing on the right-hand side of this OPE depend on N and the level k of the bosonic spin-1 affine Kac-Moody current. For convenience, the above 136 OPEs in the component approach for generic ( N, k) with simplified notation are given.

  8. Prediction of Pollution Flashover Voltage Based on Leakage Current Under AC Operating Voltage

    Institute of Scientific and Technical Information of China (English)

    MEI Hongwei; WANG Liming; GUAN Zhicheng; MAO Yingke

    2012-01-01

    This paper presented a model to predict the AC flashover voltage of contaminated suspension insulators.The prediction method is based on the maximum leakage current under AC operating voltage.Three kinds of widely used suspension insulators were tested in various contamination states such as pollution layers with different equivalent salt deposit density(ESDD),different composition of the conductive components,different non-soluble deposit density(NSDD) and different pollution distribution states to simulate the contamination states in nature.The effective ESDD was proposed and calculated.Influences of contamination states to maximum leakage current and flashover voltage were studied.Then,the relationships between flashover voltage and leakage current in these states were presented.Finally,considering the difference of insulator profiles,a new parameter is defined and a model to estimate the flashover voltage based on this parameter is developed.The model could be used in all kinds of suspension insulators in different contamination states and was validated by the test results.

  9. Remedial investigation/feasibility study work plan for the 100-KR-4 operable unit, Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1992-09-01

    Four areas of the Hanford Site (the 100, 200, 300, and 1100 Areas) have been included on the US Environmental Protection Agency`s (EPA`s) National Priorities List (NPL) under the Comprehensive Environmental Response, Compensation, and Liability Act of 1980 (CERCLA). This work plan and the attached supporting project plans establish the operable unit setting and the objectives, procedures, tasks, and schedule for conducting the CERCLA remedial investigation/feasibility study (RI/FS) for the 100-KR-4 operable unit. The 100-K Area consists of the 100-KR-4 groundwater operable unit and three source operable units. The 100-KR-4 operable unit includes all contamination found in the aquifer soils and water beneath the 100-K Area. Source operable units include facilities and unplanned release sites that are potential sources of contamination.

  10. Development of a Multi-Site and Multi-Device Webgis-Based Tool for Tidal Current Energy Development

    Science.gov (United States)

    Ang, M. R. C. O.; Panganiban, I. K.; Mamador, C. C.; De Luna, O. D. G.; Bausas, M. D.; Cruz, J. P.

    2016-06-01

    A multi-site, multi-device and multi-criteria decision support tool designed to support the development of tidal current energy in the Philippines was developed. Its platform is based on Geographic Information Systems (GIS) which allows for the collection, storage, processing, analyses and display of geospatial data. Combining GIS tools with open source web development applications, it becomes a webGIS-based marine spatial planning tool. To date, the webGIS-based tool displays output maps and graphs of power and energy density, site suitability and site-device analysis. It enables stakeholders and the public easy access to the results of tidal current energy resource assessments and site suitability analyses. Results of the initial development showed that it is a promising decision support tool for ocean renewable energy project developments.

  11. Effect of Pre-Operative Use of Medications on the Risk of Surgical Site Infections in Patients Undergoing Cardiac Surgery.

    Science.gov (United States)

    Eton, Vic; Sinyavskaya, Liliya; Langlois, Yves; Morin, Jean François; Suissa, Samy; Brassard, Paul

    2016-10-01

    Median sternotomy, the most common means of accessing the heart for cardiac procedures, is associated with higher risk of surgical site infections (SSIs). A limited number of studies reporting the impact of medication use prior to cardiac surgery on the subsequent risk of SSIs usually focused on antibacterial prophylaxis. The objective of the current study was to evaluate the effect of medications prescribed commonly to cardiac patients on the risk of incident SSIs. The study analyzed data on consecutive cardiac surgery patients undergoing median sternotomy at a McGill University teaching hospital between April 1, 2011 and October 31, 2013. Exposure of interest was use of medications for heart disease and cardiovascular conditions in the seven days prior to surgery and those for comorbid conditions. The main outcome was SSIs occurring within 90 d after surgery. Univariate and multivariate logistic regression (adjusted odds ratio [AOR]) was used to evaluate the effect. The cohort included 1,077 cardiac surgery patients, 79 of whom experienced SSIs within 90 d of surgery. The rates for sternal site infections and harvest site infections were 5.8 (95% confidence interval [CI]: 4.4-7.3) and 2.5 (95% CI: 1.4-3.7) per 100 procedures, respectively. The risk of SSI was increased with the pre-operative use of immunosuppressors/steroids (AOR 3.47, 95% CI: 1.27-9.52) and α-blockers (AOR 3.74, 95% CI: 1.21-1.47). Our findings support the effect of immunosuppressors/steroids on the risk of SSIs and add evidence to the previously reported association between the use of anti-hypertensive medications and subsequent development of infection/sepsis.

  12. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    Energy Technology Data Exchange (ETDEWEB)

    Parsapour, Amir, E-mail: amirparsapour@gmail.com [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Dehkordi, Behzad Mirzaeian, E-mail: mirzaeian@eng.ui.ac.ir [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Moallem, Mehdi, E-mail: moallem@cc.iut.ac.ir [Department of Electrical Engineering, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2015-03-15

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated.

  13. ANALYSIS OF SUFFICIENCY OF THE BEARING CAPACITY OF BUILDING STRUCTURES OF OPERATING SITES OF MAIN BUILDINGS OF THERMAL POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Alekseeva Ekaterina Leonidovna

    2012-10-01

    Full Text Available Upon examination of eleven main buildings of power plants, analysis of defects and damages of building structures was performed. Thereafter, the damageability of principal bearing structures of main buildings of thermal plants was analyzed. It was identified that the fastest growing defects and damages were concentrated in the structures of operating sites. The research of the rate of development of the most frequent damages and defects made it possible to conclude that internal corrosion of the reinforcing steel was the most dangerous defect, as far as the reinforced concrete elements of operating sites were concerned. Methods of mathematical statistics were applied to identify the reinforcing steel development pattern inside reinforced concrete elements of floors of operating sites. It was identified that the probability of corrosion of reinforced concrete elements of operating sites was distributed in accordance with the demonstrative law. Based on these data, calculation of strength of reinforced concrete slabs and metal beams was performed in terms of their regular sections, given the natural loads and the realistic condition of structures. As a result, dependence between the bearing capacity reserve ratio and the corrosion development pattern was identified for reinforced concrete slabs and metal beams of operating sites. In order to analyze the sufficiency of the bearing capacity of building structures of operating sites in relation to their time in commission, equations were derived to identify the nature of dependence between the sufficiency of the bearing capacity of reinforced concrete slabs and metal beams of the operating sites and their time in commission.

  14. 75 FR 70688 - Actel Corporation, Currently Known as Microsemi Corporation, Including On-Site Leased Workers...

    Science.gov (United States)

    2010-11-18

    ... On-Site Leased Workers From ATR International, Accountants, Inc. and Accountant Temps Mountain View... International, Accountants, Inc., and Accountant Temps, Mountain View, California. The notice was published in... Microsemi Corporation, including on-site leased workers from ATE International, Accountants, Inc.,...

  15. A Review & Assessment of Current Operating Conditions Allowable Stresses in ASME Section III Subsection NH

    Energy Technology Data Exchange (ETDEWEB)

    R. W. Swindeman

    2009-12-14

    The current operating condition allowable stresses provided in ASME Section III, Subsection NH were reviewed for consistency with the criteria used to establish the stress allowables and with the allowable stresses provided in ASME Section II, Part D. It was found that the S{sub o} values in ASME III-NH were consistent with the S values in ASME IID for the five materials of interest. However, it was found that 0.80 S{sub r} was less than S{sub o} for some temperatures for four of the materials. Only values for alloy 800H appeared to be consistent with the criteria on which S{sub o} values are established. With the intent of undertaking a more detailed evaluation of issues related to the allowable stresses in ASME III-NH, the availabilities of databases for the five materials were reviewed and augmented databases were assembled.

  16. Fast pulsed operation of a small non-radioactive electron source with continuous emission current control.

    Science.gov (United States)

    Cochems, P; Kirk, A T; Bunert, E; Runge, M; Goncalves, P; Zimmermann, S

    2015-06-01

    Non-radioactive electron sources are of great interest in any application requiring the emission of electrons at atmospheric pressure, as they offer better control over emission parameters than radioactive electron sources and are not subject to legal restrictions. Recently, we published a simple electron source consisting only of a vacuum housing, a filament, and a single control grid. In this paper, we present improved control electronics that utilize this control grid in order to focus and defocus the electron beam, thus pulsing the electron emission at atmospheric pressure. This allows short emission pulses and excellent stability of the emitted electron current due to continuous control, both during pulsed and continuous operations. As an application example, this electron source is coupled to an ion mobility spectrometer. Here, the pulsed electron source allows experiments on gas phase ion chemistry (e.g., ion generation and recombination kinetics) and can even remove the need for a traditional ion shutter.

  17. Establishing Specifications for Low Enriched Uranium Fuel Operations Conducted Outside the High Flux Isotope Reactor Site

    Energy Technology Data Exchange (ETDEWEB)

    Pinkston, Daniel [ORNL; Primm, Trent [ORNL; Renfro, David G [ORNL; Sease, John D [ORNL

    2010-10-01

    The National Nuclear Security Administration (NNSA) has funded staff at Oak Ridge National Laboratory (ORNL) to study the conversion of the High Flux Isotope Reactor (HFIR) from the current, high enriched uranium fuel to low enriched uranium fuel. The LEU fuel form is a metal alloy that has never been used in HFIR or any HFIR-like reactor. This report provides documentation of a process for the creation of a fuel specification that will meet all applicable regulations and guidelines to which UT-Battelle, LLC (UTB) the operating contractor for ORNL - must adhere. This process will allow UTB to purchase LEU fuel for HFIR and be assured of the quality of the fuel being procured.

  18. Current and Future Impact Risks from Small Debris to Operational Satellites

    Science.gov (United States)

    Liou, Jer-Chyi; Kessler, Don

    2011-01-01

    The collision between Iridium 33 and Cosmos 2251 in 2009 signaled the potential onset of the collision cascade effect, commonly known as the "Kessler Syndrome", in the low Earth orbit (LEO) region. Recent numerical simulations have shown that the 10 cm and larger debris population in LEO will continue to increase even with a good implementation of the commonly-adopted mitigation measures. This increase is driven by collisions involving large and massive intacts, i.e., rocket bodies and spacecraft. Therefore, active debris removal (ADR) of large and massive intacts with high collision probabilities has been argued as a direct and effective means to remediate the environment in LEO. The major risk for operational satellites in the environment, however, comes from impacts with debris just above the threshold of the protection shields. In general, these are debris in the millimeter to centimeter size regime. Although impacts by these objects are insufficient to lead to catastrophic breakup of the entire vehicle, the damage is certainly severe enough to cause critical failure of the key instruments or the entire payload. The focus of this paper is to estimate the impact risks from 5 mm and 1 cm debris to active payloads in LEO (1) in the current environment and (2) in the future environment based on different projection scenarios, including ADR. The goal of the study is to quantify the benefits of ADR in reducing debris impact risks to operational satellites.

  19. Progress toward steady-state tokamak operation exploiting the high bootstrap current fraction regime

    Science.gov (United States)

    Ren, Q. L.; Garofalo, A. M.; Gong, X. Z.; Holcomb, C. T.; Lao, L. L.; McKee, G. R.; Meneghini, O.; Staebler, G. M.; Grierson, B. A.; Qian, J. P.; Solomon, W. M.; Turnbull, A. D.; Holland, C.; Guo, W. F.; Ding, S. Y.; Pan, C. K.; Xu, G. S.; Wan, B. N.

    2016-06-01

    Recent DIII-D experiments have increased the normalized fusion performance of the high bootstrap current fraction tokamak regime toward reactor-relevant steady state operation. The experiments, conducted by a joint team of researchers from the DIII-D and EAST tokamaks, developed a fully noninductive scenario that could be extended on EAST to a demonstration of long pulse steady-state tokamak operation. Improved understanding of scenario stability has led to the achievement of very high values of βp and βN , despite strong internal transport barriers. Good confinement has been achieved with reduced toroidal rotation. These high βp plasmas challenge the energy transport understanding, especially in the electron energy channel. A new turbulent transport model, named TGLF-SAT1, has been developed which improves the transport prediction. Experiments extending results to long pulse on EAST, based on the physics basis developed at DIII-D, have been conducted. More investigations will be carried out on EAST with more additional auxiliary power to come online in the near term.

  20. Ion properties in a Hall current thruster operating at high voltage

    Science.gov (United States)

    Garrigues, L.

    2016-04-01

    Operation of a 5 kW-class Hall current Thruster for various voltages from 400 V to 800 V and a xenon mass flow rate of 6 mg s-1 have been studied with a quasi-neutral hybrid model. In this model, anomalous electron transport is fitted from ion mean velocity measurements, and energy losses due to electron-wall interactions are used as a tuned parameter to match expected electron temperature strength for same class of thruster. Doubly charged ions production has been taken into account and detailed collisions between heavy species included. As the electron temperature increases, the main channel of Xe2+ ion production becomes stepwise ionization of Xe+ ions. For an applied voltage of 800 V, the mass utilization efficiency is in the range of 0.8-1.1, and the current fraction of doubly charged ions varies between 0.1 and 0.2. Results show that the region of ion production of each species is located at the same place inside the thruster channel. Because collision processes mean free path is larger than the acceleration region, each type of ions experiences same potential drop, and ion energy distributions of singly and doubly charged are very similar.

  1. An Initial Evaluation of Siting Considerations on Current and Future Wind Deployment

    Energy Technology Data Exchange (ETDEWEB)

    Tegen, Suzanne [National Renewable Energy Lab. (NREL), Golden, CO (United States); Lantz, Eric [National Renewable Energy Lab. (NREL), Golden, CO (United States); Mai, Trieu [National Renewable Energy Lab. (NREL), Golden, CO (United States); Heimiller, Donna [National Renewable Energy Lab. (NREL), Golden, CO (United States); Hand, Maureen [National Renewable Energy Lab. (NREL), Golden, CO (United States); Ibanez, Eduardo [GE Energy Consulting, Denver, CO (United States)

    2016-07-01

    This report provides a deeper understanding of the wind project development process, from desktop studies to a successful project in the ground. It examines three siting consideration categories that wind project sponsors must include in the development process: wildlife (species that live in, near, or migrate through the area where wind development is possible), radar (wind turbines can cause interference with radar signals), and public engagement (representing communities and stakeholders who live near wind power projects). The research shows that although this country's abundant wind resource provides numerous options for addressing siting considerations, actually siting individual projects is becoming more difficult because of regulatory and other uncertainties. Model results are based on the premise that developers will be able to site, permit, and build successful projects, which is not always the case in reality.

  2. 78 FR 12358 - UBS Financial Services, Inc., Wealth Management Americas Operations, Including On-Site Leased...

    Science.gov (United States)

    2013-02-22

    ... Employment and Training Administration UBS Financial Services, Inc., Wealth Management Americas Operations..., applicable to workers of UBS Financial Services, Inc., Wealth Management Americas Operations (UBS), Weehawken... Management Americas Operations (UBS), Weehawken, New Jersey, who were all adversely affected by the...

  3. A System-Wide Approach to Physician Efficiency and Utilization Rates for Non-Operating Room Anesthesia Sites.

    Science.gov (United States)

    Tsai, Mitchell H; Huynh, Tinh T; Breidenstein, Max W; O'Donnell, Stephen E; Ehrenfeld, Jesse M; Urman, Richard D

    2017-07-01

    There has been little in the development or application of operating room (OR) management metrics to non-operating room anesthesia (NORA) sites. This is in contrast to the well-developed management framework for the OR management. We hypothesized that by adopting the concept of physician efficiency, we could determine the applicability of this clinical productivity benchmark for physicians providing services for NORA cases at a tertiary care center. We conducted a retrospective data analysis of NORA sites at an academic, rural hospital, including both adult and pediatric patients. Using the time stamps from WiseOR® (Palo Alto, CA), we calculated site utilization and physician efficiency for each day. We defined scheduling efficiency (SE) as the number of staffed anesthesiologists divided by the number of staffed sites and stratified the data into three categories (SE 1). The mean physician efficiency was 0.293 (95% CI, [0.281, 0.305]), and the mean site utilization was 0.328 (95% CI, [0.314, 0.343]). When days were stratified by scheduling efficiency (SE 1), we found differences between physician efficiency and site utilization. On days where scheduling efficiency was less than 1, that is, there are more sites than physicians, mean physician efficiency (95% CI, [0.326, 0.402]) was higher than mean site utilization (95% CI, [0.250, 0.296]). We demonstrate that scheduling efficiency vis-à-vis physician efficiency as an OR management metric diverge when anesthesiologists travel between NORA sites. When the opportunity to scale operational efficiencies is limited, increasing scheduling efficiency by incorporating different NORA sites into a "block" allocation on any given day may be the only suitable tactical alternative.

  4. Correlational and Differential Influence of Historical Cost and Current Cost Profits on the Operating Capabilities of the Firm

    OpenAIRE

    S. A. Effiong; J. O. Udoayang; A. I. Asuquo

    2011-01-01

    The study investigated the correlation and differential influence of historical cost and current cost profits on the operating capabilities of the firm. The financial statements of thirty-one Nigerian Companies were surveyed and adjusted for effects of price changes using the Consumers¡¯ Price Index (CPI). Correlation influence between the historical cost profits on the operating ability of the firm was measured and established on one hand and that of current cost profit on the other hand. Di...

  5. ADVANTAGES AND DISADVANTAGES TO OPERATING AN ON-SITE LABORATORY AT THE SANDIA NATIONAL LABORATORIES CHEMICAL WASTE LANDFILL

    Energy Technology Data Exchange (ETDEWEB)

    Young, S.G.; Creech, M.N.

    2003-02-27

    During the excavation of the Sandia National Laboratories, New Mexico (SNL/NM) Chemical Waste Landfill (CWL), operations were realized by the presence of URS' (formerly known as United Research Services) On-site Mobile Laboratory (OSML) and the close proximity of the SNL/NM Environmental Restoration Chemical Laboratory (ERCL). The laboratory was located adjacent to the landfill in order to provide soil characterization, health and safety support, and waste management data. Although the cost of maintaining and operating an analytical laboratory can be higher than off-site analysis, there are many benefits to providing on site analytical services. This paper describes the synergies between the laboratory, as well as the advantages and disadvantages to having a laboratory on-site during the excavation of SNL/NM CWL.

  6. U.S. Department of Energy, Nevada Operations Office, environmental data report for the Nevada Test Site -- 1995

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Townsend, Y.E. [eds.; Kinnison, R.R.

    1997-10-01

    The US Department of Energy (DOE) Order 5400.1, ``General Environmental Protection Program,`` establishes environmental protection program requirements, authorities, and responsibilities for DOE operations. These mandates require compliance with applicable federal, state, and local environmental protection regulations. During calendar year (CY) 1995 environmental protection and monitoring programs were conducted at the Nevada Test Site (NTS) and other DOE Nevada Operations Office (DOE/NV) managed sites in Nevada and across the United States. A detailed discussion of these environmental protection and monitoring programs, and summary data and assessments for environmental monitoring results at these sites in CY 1995 are provided in the DOE/NV, Annual Site Environmental Report--1995, (ASER) DOE/NV/11718-037. A brief description of the scope of this environmental monitoring is provided below, categorized by ``on-NTS`` and ``off-NTS`` monitoring.

  7. Operational Circular No. 2 (Rev. 3) - Conditions of access to the fenced parts of the CERN site

    CERN Multimedia

    HR Department

    2015-01-01

    Operational Circular No. 2 (Rev. 3) entitled "Conditions of access to the fenced parts of the CERN site", approved by the Director-General following discussion in the Standing Concertation Committee meeting on 24 September 2015, is now available via this link.   This revised circular cancels and replaces Operational Circular No. 2 (Rev. 2) also entitled "Conditions of access to the fenced parts of the CERN site", of September 2014. The circular was revised predominantly in order to specify that access to the CERN site is granted to CERN Pension Fund beneficiaries only provided that they are actually in receipt of payments from the Fund; and to allow the Director-General to permit special types of vehicles on site, such as trailers. It also includes a certain number of text improvements and an updated version of the implementation measures, in particular with regard to vehicle identification, road traffic and parking.  

  8. Current status of multimodel superensemble and operational NWP forecast of the Indian summer monsoon

    Indian Academy of Sciences (India)

    Akhilesh Kumar Mishra; T N Krishnamurti

    2007-10-01

    In the last thirty years great strides have been made by large-scale operational numerical weather prediction models towards improving skills for the medium range time-scale of 7 days.This paper illustrates the use of these current forecasts towards the construction of a consensus multimodel forecast product called the superensemble.This procedure utilizes 120 of the recent-past forecasts from these models to arrive at the training phase statistics. These statistics are described by roughly 107 weights.Use of these weights provides the possibility for real-time medium range forecasts with the superensemble.We show the recent status of this procedure towards real-time forecasts for the Asian summer monsoon.The member models of our suite include ECMWF,NCEP/EMC, JMA,NOGAPS (US Navy),BMRC,RPN (Canada)and an FSU global spectral forecast model. We show in this paper the skill scores for day 1 through day 6 of forecasts from standard variables such as winds,temperature,500 hPa geopotential height,sea level pressure and precipitation.In all cases we noted that the superensemble carries a higher skill compared to each of the member models and their ensemble mean.The skill matrices we use include the RMS errors,the anomaly correlations and equitable threat scores.For many of these forecasts the improvements of skill for the superensemble over the best model was found to be quite substantial.This real-time product is being provided to many interested research groups.The FSU multimodel superensemble,in real- time,stands out for providing the least errors among all of the operational large scale models.

  9. Current and emerging techniques for contaminant mapping and data visualization at DNAPL sites

    DEFF Research Database (Denmark)

    Wealthall, Gary; Durant, Neal; Grosen, Bernt

    Recent advances in the development of contaminant specific site investigation tools has significantly enhanced our ability to characterize the spatial architecture of DNAPL source zones in both sedimentary and fractured bedrock environments. The application of innovative site characterization...... methods will be discussed in the context of contaminant delineation, remediation design, technology verification and regulatory acceptance. We present a range of site investigation tools, based on the principle of combined lines of evidence and the premise that a single technique is not available to fully...... delineate DNAPL distribution in the subsurface. Key to this strategy is the selection of technologies with multiple scales of measurement and data quality, of which there are two main categories. The first category provides qualitative, dense spatial data, often with higher detection limits over a preset...

  10. The Observatorio Astrofísico de Javalambre: current status, developments, operations, and strategies

    Science.gov (United States)

    Cenarro, A. J.; Moles, M.; Marín-Franch, A.; Cristóbal-Hornillos, D.; Yanes Díaz, A.; Ederoclite, A.; Varela, J.; Vázquez-Ramió, H.; Valdivielso, L.; Benítez, N.; Cepa, J.; Dupke, R.; Fernández-Soto, A.; Mendes de Oliveira, C.; Sodré, L.; Taylor, K.; Rueda-Teruel, S.; Rueda-Teruel, F.; Luis-Simoes, R.; Chueca, S.; Antón, J. L.; Bello, R.; Díaz-Martín, M. C.; Guillén-Civera, L.; Hernández-Fuertes, J.; Iglesias-Marzoa, R.; Jiménez-Mejías, D.; Lasso-Cabrera, N. M.; López-Alegre, G.; López-Sainz, A.; Rodríguez-Hernández, M. A. C.; Suárez, O.; Lamadrid, J. L.; Maícas, N.; Abril-Ibañez, J.; Tilve, V.; Rodríguez-Llano, S.

    2014-08-01

    fully operative. This paper aims to present a brief description and status of the OAJ main installations, telescopes and cameras. The current development and operation plan of the OAJ in terms of staffing organization, resources, observation scheduling, and data archiving, is also described.

  11. Torque harmonics of an asynchronous motor supplied by a voltage- or current-sourced inverter quasi-square operation

    Energy Technology Data Exchange (ETDEWEB)

    Kyyrae, J. [Helsinki University of Technology, Institute of Intelligent Power Electronics, Espoo (Finland)

    1997-12-31

    Voltage- and current-sourced dc-ac converters operating in quasi-square area are compared. Their characteristics are calculated with switching vector, which is space-vector of switching functions. When the load is an asynchronous motor various analytical equations, including torque, are calculated efficiently. Motor current and torque approximations are compared with the simulated ones. (orig.) 6 refs.

  12. Current State of Web Sites in Science Education--Focus on Atomic Structure.

    Science.gov (United States)

    Tuvi, Inbal; Nachmias, Rafi

    2001-01-01

    Explores to what extent the web's advanced graphical tools and computational power are implemented in science education. Focuses on the pedagogical and technological characteristics of web sites attempting to teach the subject of atomic structure. (Contains 33 references.) (Author/YDS)

  13. The Operator Product Expansion between the 16 Lowest Higher Spin Currents in the N=4 Superspace

    CERN Document Server

    Ahn, Changhyun

    2015-01-01

    Some of the operator product expansions (OPEs) between the lowest 16 higher spin currents of spins (1, 3/2, 3/2, 3/2, 3/2, 2, 2, 2, 2, 2, 2, 5/2, 5/2, 5/2, 5/2, 3) in an extension of the large N=4 linear superconformal algebra were constructed in the N=4 superconformal coset SU(5)/SU(3) theory previously. In this paper, by rewriting the above OPEs in the N=4 superspace developed by Schoutens (and other groups), the remaining undetermined OPEs where the corresponding singular terms possess the composite fields with spins s =7/2, 4, 9/2, 5 are completely determined. Furthermore, by introducing the arbitrary coefficients in front of the composite fields in the right hand sides of the above complete 136 OPEs, reexpressing them in the N=2 superspace and using the N=2 OPEs mathematica package by Krivonos and Thielemans, the complete structures of the above OPEs with fixed coefficient functions are obtained with the help of various Jacobi identities. Then one obtains ten N=2 super OPEs between the four N=2 higher sp...

  14. Current gaps in understanding and predicting space weather: An operations perspective

    Science.gov (United States)

    Murtagh, W. J.

    2016-12-01

    The NOAA Space Weather Prediction Center (SWPC), one of the nine National Weather Service (NWS) National Centers for Environmental Prediction, is the Nation's official source for space weather alerts and warnings. Space weather effects the technology that forms the backbone of global economic vitality and national security, including satellite and airline operations, communications networks, and the electric power grid. Many of SWPC's over 48,000 subscribers rely on space weather forecasts for critical decision making. But extraordinary gaps still exist in our ability to meet customer needs for accurate and timely space weather forecasts and warnings. The 2015 National Space Weather Strategy recognizes that it is imperative that we improve the fundamental understanding of space weather and increase the accuracy, reliability, and timeliness of space-weather observations and forecasts in support of the growing demands. In this talk we provide a broad perspective of the key challenges that currently limit the forecaster's ability to better understand and predict space weather. We also examine the impact of these limitations on the end-user community.

  15. Simplified Modeling, Analysis and Simulation of Permanent Magnet Brushless Direct Current Motors for Sensorless Operation

    Directory of Open Access Journals (Sweden)

    E. Kaliappan

    2012-01-01

    Full Text Available Problem statement: In this study, a simplified modeling and experimental analysis of Permanent Magnet Brushless DC (PMBLDC motors for Sensorless operation using MATLAB/SIMULINK. This model provides a mechanism for monitoring and controlling the voltage, current, speed and torque response. Approach: BLDC motor is modeled as sub-blocks. The inverter and switching function are implemented as S-function builder block. The Sensorless scheme employs direct back emf based zero crossing detection technique. Results: The proposed model with Sensorless control technique with back emf zero crossing detection is tested in the BLDC Motor and the performance was evaluated. The simulated and experimental results show that the proposed modeling works quite well during starting and running conditions. Conclusion/Recommendation: The developed model consists of several independent sub-blocks, that can be used in the modeling of Permanent Magnet Sinusoidal Motor and induction motor. Hence the developed simulation model is a design tool to study the dynamic behavior of Sensorless Controlled Brushless DC Motor.

  16. High-Current Bus Splice Resistances and Implications for the Operating Energy of the LHC

    CERN Document Server

    Koratzinos, M; Charifoulline, Z; Dahlerup-Petersen, K; Denz, R; Flora, R H; Pfeffer, H; Scheuerlein, C; Schmidt, R; Siemko, A; Strait, J; Verweij, A

    2010-01-01

    At each interconnection between LHC main magnets a low-resistance solder joint must be made between superconducting cables in order to provide a continuous current path through the superconductor and also to the surrounding copper stabilizer in case the cable quenches [1]. About 10,000 such joints exist in the LHC. An extensive campaign has been undertaken to characterize and map the resistances of these joints. All of the superconducting cable splices were measured at 1.9 K and no splices were found with a resistance larger than 3 nW. Non-invasive measurements of the stabilizer joints were made at 300 K in 5 of the 8 sectors, and at 80 K in 3 sectors. More precise local measurements were made on suspect interconnects that were opened up, and poor joints were repaired. However, it is likely that additional imperfect stabilizer joints still exist in the LHC. A statistical analysis is used to place bounds on the remaining worst-case resistances. This sets limits on the maximum operating energy of the LHC, prior...

  17. High-Precision Multi-Wave Rectifier Circuit Operating in Low Voltage + 1.5 Volt Current Mode

    Directory of Open Access Journals (Sweden)

    Bancha Burapattanasiri

    2009-12-01

    Full Text Available This article is present high-precision multi-wave rectifier circuit operating in low voltage +/- 1.5 Volt current modes by CMOS technology 0.5 μm, receive input and give output in current mode, respond at high frequency period. The structure compound with high-speed current comparator circuit, current mirror circuit, and CMOS inverter circuit. PSpice program used for confirmation the performance of testing. The PSpice program shows operating of circuit is able to working at maximum input current 400 μAp-p, maximum frequency responding 200 MHz, high precision and low power losses, and non-precision zero crossing output signal.Keywords-component; rectifier circuit; high-precision; low voltage; current mode;

  18. US Department of Energy Nevada Operations Office annual site environmental report: 1993. Volume 1

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Glines, W.M.; Townsend, Y.E. [eds.

    1994-09-01

    Monitoring and surveillance on and around the Nevada Test Site (NTS) by DOE contractors and NTS user organizations during 1993 indicated that operations on the NTS were conducted in compliance with applicable federal and DOE guidelines, i.e., the dose the maximally exposed offsite individual could have received was less than 0.04 percent of the 10 mrem per year guide for air exposure. No nuclear tests were conducted due to the moratorium. All discharges of radioactive liquids remained onsite in containment ponds, and there was no indication of potential migration of radioactivity to the offsite area through groundwater. Surveillance around the NTS indicated that airborne radioactivity from diffusion, evaporation of effluents, or resuspension was not detectable offsite, and no measurable net exposure to members of the offsite population was detected through the offsite dosimetry program. Using the CAP88-PC model and NTS radionuclide emissions data, the calculated effective dose equivalent to the maximally exposed individual offsite would have been 0.004 mrem. Any person receiving this dose would also have received 97 mrem from natural background radiation. There were no nonradiological releases to the offsite area. Hazardous wastes were shipped offsite to approved disposal facilities. Compliance with the various regulations stemming from the National Environmental Policy Act is being achieved and, where mandated, permits for air and water discharges and waste management have been obtained from the appropriate agencies. Support facilities at off-NTS locations compiled with the requirements of air quality permits and state or local wastewater discharge and hazardous waste permits.

  19. Adaptive Hybrid Fuzzy-Proportional Plus Crisp-Integral Current Control Algorithm for Shunt Active Power Filter Operation

    Directory of Open Access Journals (Sweden)

    Nor Farahaida Abdul Rahman

    2016-09-01

    Full Text Available An adaptive hybrid fuzzy-proportional plus crisp-integral current control algorithm (CCA for regulating supply current and enhancing the operation of a shunt active power filter (SAPF is presented. It introduces a unique integration of fuzzy-proportional (Fuzzy-P and crisp-integral (Crisp-I current controllers. The Fuzzy-P current controller is developed to perform gain tuning procedure and proportional control action. This controller inherits the simplest configuration; it is constructed using a single-input single-output fuzzy rule configuration. Thus, an execution of few fuzzy rules is sufficient for the controller’s operation. Furthermore, the fuzzy rule is developed using the relationship of currents only. Hence, it simplifies the controller development. Meanwhile, the Crisp-I current controller is developed to perform integral control action using a controllable gain value; to improve the steady-state control mechanism. The gain value is modified and controlled using the Fuzzy-P current controller’s output variable. Therefore, the gain value will continuously be adjusted at every sample period (or throughout the SAPF operation. The effectiveness of the proposed CCA in regulating supply current is validated in both simulation and experimental work. All results have proven that the SAPF using the proposed CCA is capable to regulate supply current during steady-state and dynamic-state operations. At the same time, the SAPF is able to enhance its operation in compensating harmonic currents and reactive power. Furthermore, the implementation of the proposed CCA has resulted more stable dc-link voltage waveform.

  20. Current Aeromedical Issues in Rotary Wing Operations. (Problemes actuels de medecine aeronautique poses par les operations utilisant des voilures tournantes)

    Science.gov (United States)

    1999-08-01

    accident, the other had early ankylosing malformation (eg spondylolisthesis) and previous spinal spondylitis . surgery. The current locations of all...Caldwell, K.A. Roberts and H.D. Jones The Effects of Exercise Versus Napping on Alertness and Mood in Sleep-Deprived Aviators 28 by P.A. LeDuc, J.A...for aircrew and passengers involved of Zolpiden and exercise on the performance of in mishaps. It was made by an analysis of sleep deprived pilots

  1. 76 FR 66328 - Callaway Golf Ball Operations, Inc., Including On-Site Leased Workers From Reliable Temp Services...

    Science.gov (United States)

    2011-10-26

    ... From Reliable Temp Services, Inc., Johnson & Hill Staffing and Apollo Security, Chicopee, MA; Amended... from Reliable Temp Services, Inc., and Johnson and Hill Staffing, Chicopee, Massachusetts. The workers... Operations, Inc., including on-site leased workers from Reliable Temp Services, Inc., Johnson & Hill Staffing...

  2. Site Environmental Report for Calendar Year 2007. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Rutherford, Phil [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Lenox, Art [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Blair, Lori [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Amar, Ravnesh [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Costa, Paul [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Galvez, Lydia [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Jameson, Blythe [Santa Susana Field Laboratory, CA (United States). The Boeing Company; Galvez, Lydia [Santa Susana Field Laboratory, CA (United States). The Boeing Company

    2008-09-30

    This Annual Site Environmental Report (ASER) for 2007 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended until DOE completes the SSFL Area IV Environmental Impact Statement (EIS). The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2007 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. All radioactive wastes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for radioactive waste disposal. No liquid radioactive wastes were released into the environment in 2007.

  3. Smooth Operator - Mobile Information Technology for Improved Flow at the Construction Site

    DEFF Research Database (Denmark)

    Tambo, Torben

    2010-01-01

    and industry for an updated and forward looking comprehension, and view of tendencies, of the roles and potentials of mobile IT at the construction site including potential for further research. Qualitative and interpretive methodology inspired by information systems and sociology of research and construction...... and micro mobility (the site); additionally systems designed for the construction site are used in increasingly adjacent industries: Architects, engineers, facility management, insurance, etc. The ambiguousness of mobile IT on the construction site strongly supports further research within this field using...

  4. The current status of procedural sedation for pediatric patients in out-of-operating room locations.

    Science.gov (United States)

    Havidich, Jeana E; Cravero, Joseph P

    2012-08-01

    To illustrate the changes that are occurring in the rapidly growing field of pediatric sedation. In the USA and throughout the world, children receive sedation from a multitude of specialists with varying levels of training. The current pediatric sedation literature reflects a growing body of sedation literature by medical specialists other than anesthesiologists. This article will review the controversial use of propofol by nonanesthesiologists and the manner in which this varied group of providers along with government entities, regulatory agencies, and national organizations contribute to the continuing evolution of sedation practices. The number of diagnostic and therapeutic procedures performed on children outside of the operating room continues to increase. The growing body of pediatric sedation literature suggests anesthesiologists are no longer at the forefront of pediatric sedation training, education, and research. Articles published by nonanesthesiologists describe pediatric sedation services, safety, and quality initiatives, drugs, and original sedation research. Medications that were considered under the realm of anesthesiologists are utilized by nonanesthesiologists to provide sedation to children. Regulating and government agencies, including the Joint Commission and the Center for Medicaid and Medicare Services have recently issued statements on the oversight and practice of sedation. The direction of pediatric sedation is no longer solely under the leadership of anesthesiologists. The use of anesthetic agents, including propofol, have been administered by nonanesthesiologists and reported as safe and effective agents. Nonanesthesiologists and governmental and regulatory agencies influence the delivery of sedation services. The future direction of pediatric sedation will ultimately depend upon the ability of anesthesiologists to collaborate with specialists, hospital administrators, credentialing committees, and oversight agencies in order to

  5. INCREASE THE RESOURCE OF CURRENT COLLECTOR ELEMENTS OF THE ELECTRIFIED HIGH-SPEED TRANSPORT IN OPERATING CONDITIONS

    Directory of Open Access Journals (Sweden)

    Y. L. Bolshakov

    2015-07-01

    Full Text Available Purpose. The paper is aimed to determinate the main ways of increasing resource efficiency and exploitation of coal current collector surface inserts of speed electric rolling stock. Methodology. The research is based on the technique relies on the use of theory regulations of technical systems reliability, electromechanical processes, theory of statistics. Findings. The existing approaches to the production of current collector surface inserts in Europe and Ukraine were considered, a number of information sources was analyzed. The most effective ways of increasing current carrying capacity and wear resistance of current collector elements were determined. It has been established that the existing system for determining the quality of manufacturing of current collector elements have a number of drawbacks that make it difficult to control the input and makes diagnosing current collecting elements in operation impossible. On the basis of the facts, for the needs of the locomotive depot, we propose a new booth allowing avoiding the existing difficulties with diagnosing of current collector elements. During the study were established pervasive transgressions of technological standards of service pantographs. Originality. Based on the results of operational research carried out on the basis of the locomotive depot, obtained depending, based on which, it is proposed to introduce an operative diagnosing system of the current collector elements state during operation. In the course of a comparative analysis of existing and perspective development directions of current collector elements with high load current carrying capacity and durability, were definited constructive conditions for the optimal ratio is inserts. It was established that a significant proportion of failures occur due to imperfect maintenance system for which, on the basis of operational data, recommendations were developed. Practical value. Obtained results of the information sources

  6. Prolonged time course of glutamate-operated single channel currents in neuromuscular preparations of small crayfish and a membrane current triggered by glutamate channel gating.

    Science.gov (United States)

    Finger, W; Martin, C; Pareto, A

    1988-08-31

    Single channel currents activated by glutamate were recorded by means of the patch-clamp technique in the abdominal superficial extensor muscle and the claw opener muscle of small (1-3 months old) and large (greater than 16 months old) crayfish. It was found that in small crayfish the time course of glutamate-operated single channel currents was prolonged by a factor of about 4 in these two preparations. In the abdominal superficial extensor muscle, single channel currents activated by 5 mmol/l glutamate had a mean burst length of tau = 2-3 ms in large crayfish and a mean burst length of tau = 8-9 ms in small crayfish. In the claw opener, for large crayfish tau congruent to 0.5 ms and for small crayfish tau = 1.5-2.5 ms resulted (500 mumol/l glutamate). Moreover, single channel currents with long time courses often slowly increased their amplitudes during the open time of the channel and current amplitudes did not decline completely to the baseline after channel closing. In addition, single channel currents with relatively constant amplitude were often followed by a small increasing and decreasing membrane current. The latter results suggest that glutamate channel gating might trigger a membrane current.

  7. Current Practices in Global/International Advanced Pharmacy Practice Experiences: Home/Host Country or Site/Institution Considerations

    OpenAIRE

    Alsharif, Naser Z.; Dakkuri, Adnan; Abrons, Jeanine P.; Williams, Dennis; Ombengi, David N.; Zheng, HaiAn; Al-Dahir, Sara; Tofade, Toyin; Gim, Suzanna; O’Connell, Mary Beth; Ratka, Anna; Dornblaser, Emily

    2016-01-01

    International outreach by schools and colleges of pharmacy is increasing. In this paper, we provide current practice guidelines to establish and maintain successful global/international advanced pharmacy practice experiences (G/I APPEs) with specific recommendations for home/host country and host site/institution. The paper is based on a literature review (2000-2014) in databases and Internet searches with specific keywords or terms. Educational documents such as syllabi and memoranda of unde...

  8. Current Practices in Global/International Advanced Pharmacy Practice Experiences: Home/Host Country or Site/Institution Considerations

    OpenAIRE

    Alsharif, Naser Z.; Dakkuri, Adnan; Abrons, Jeanine P.; Williams, Dennis; Ombengi, David N.; Zheng, HaiAn; Al-Dahir, Sara; Tofade, Toyin; Gim, Suzanna; O’Connell, Mary Beth; Ratka, Anna; Dornblaser, Emily

    2016-01-01

    International outreach by schools and colleges of pharmacy is increasing. In this paper, we provide current practice guidelines to establish and maintain successful global/international advanced pharmacy practice experiences (G/I APPEs) with specific recommendations for home/host country and host site/institution. The paper is based on a literature review (2000-2014) in databases and Internet searches with specific keywords or terms. Educational documents such as syllabi and memoranda of unde...

  9. Influence of Peri-Operative Hypothermia on Surgical Site Infection in Prolonged Gastroenterological Surgery.

    Science.gov (United States)

    Tsuchida, Toshie; Takesue, Yoshio; Ichiki, Kaoru; Uede, Takashi; Nakajima, Kazuhiko; Ikeuchi, Hiroki; Uchino, Motoi

    2016-10-01

    There have been several recent studies on the correlation between intra-operative hypothermia and the occurrence of surgical site infection (SSI). Differences in the depth and timing of hypothermia and the surgical procedure may have led to conflicting results. Patients undergoing gastroenterologic surgery with a duration of >3 h were analyzed. Hypothermia was defined as a core temperature <36°C and was classified as mild (35.5-35.9°C), moderate (35.0-35.4°C), or severe (<35.0°C). Hypothermia also was classified as early-nadir (<36°C within two h of anesthesia induction) and late-nadir (after that time). Risk factors for SSIs were analyzed according to these classifications. Among 1,409 patients, 528 (37.5%) had hypothermia, which was classified as mild in 358, moderate in 137, and severe in 33. Early-nadir and late-nadir hypothermia was found in 23.7% and 13.8%, respectively. There was no significant difference in the incidence of SSIs between patients with and without hypothermia (relative risk 1.00; 95% confidence interval [CI] 0.80-1.25; p = 0.997). However, there was a significantly greater incidence of SSIs in patients with severe hypothermia (33.3%) than in those with normothermia (19.2%; p = 0.045) or mild hypothermia (17.0%; p = 0.021). The incidence of SSIs also was significantly greater in patients with late-nadir than in those with early-nadir hypothermia (23.7% vs. 16.5%; p = 0.041). The incidence of organ/space SSIs was significantly greater in patients with late-nadir hypothermia (19.6%) than in patients with normothermia (12.7%; p = 0.012). In multivariable analysis, neither severe hypothermia (odds ratio 1.24; 95% CI 0.56-2.77] nor late-nadir hypothermia (OR 0.71; 95% CI 0.46-1.01) was an independent risk factor for SSIs. Severe and late-nadir hypothermia were associated with a greater incidence of SSIs and organ/space SSIs. However, neither of these patterns was identified as an independent risk factor for SSIs, possibly

  10. [Pre-operative smoking cessation does not always reduce the incidence of surgical site infection after gastrointestinal surgery].

    Science.gov (United States)

    Kuri, Michioki; Yamada, Terumasa; Nakagawa, Masashi; Tanigami, Hironobu; Kishi, Yoshihiko

    2011-02-01

    Centers for Disease Control (CDC) recommend pre-operative smoking cessation to reduce the risk of surgical site infection (SSI). However, whether pre-operative smoking cessation reduces the incidence of SSI for gastrointestinal surgery is unclear. We investigated whether pre-operative smoking cessation reduces the incidence of SSI among patients undergoing gastrointestinal surgery. The study subjects were 512 consecutive patients undergoing gastrointestinal surgery at Osaka Medical Center for Cancer and Cardiovascular Diseases. SSI occurrence was determined by the hospital SSI surveillance team. Pre-operative smoking status was obtained by interview, and the patients were divided into four groups. Information on age, sex, operation time, operational organ, American Society of Anesthesiologists physical status (ASA-PS), elective or emergency surgery, co-existing procedures, use of scopes, ileo-colostomy, properties of drain tube, use of floss, and wound contamination was obtained from the medical records. The relationship between smoking status and incidence of SSI, and risk factors associated with the incidence of SSI were investigated. SSI occurred in 83 patients. Pre-operative smoking status had no relation with the incidence of SSI. Operation time, gallbladder and pancreatic surgery, colon surgery, emergency surgery, co-existing procedures, ilea-colostomy, closed drain, usage of floss, and wound contamination were related significantly with SSI. Pre-operative smoking cessation does not reduce the incidence of SSI. However, since continuation of smoking has no benefits for the safety of surgery, anesthesiologists must advice patients to quit smoking before surgery.

  11. Smooth Operator - Mobile Information Technology for Improved Flow at the Construction Site

    DEFF Research Database (Denmark)

    Tambo, Torben

    2010-01-01

    and industry for an updated and forward looking comprehension, and view of tendencies, of the roles and potentials of mobile IT at the construction site including potential for further research. Qualitative and interpretive methodology inspired by information systems and sociology of research and construction......Mobile information technology (IT) seems an ideal innovation to promote effectiveness of the construction process, particularly at the construction site; research has over the last 15 years focused on solutions, potentials and barriers with this field. This paper aim at the duality between research...... and micro mobility (the site); additionally systems designed for the construction site are used in increasingly adjacent industries: Architects, engineers, facility management, insurance, etc. The ambiguousness of mobile IT on the construction site strongly supports further research within this field using...

  12. Application for Permit to Operate a Class III Solid Waste Disposal Site at the Nevada Test Site Area 5 Asbestiform Low-Level Solid Waste Disposal Site

    Energy Technology Data Exchange (ETDEWEB)

    NSTec Environmental Management

    2007-11-01

    The NTS is located approximately 105 kilometers (km) (65 miles [mi]) northwest of Las Vegas, Nevada (Figure 1). The U.S. Department of Energy (DOE) is the federal lands management authority for the NTS, and NSTec is the Management and Operations contractor. Access on and off the NTS is tightly controlled, restricted, and guarded on a 24-hour basis. The NTS has signs posted along its entire perimeter.

  13. Current Sharing inside a High Power IGBT Module at the Negative Temperature Coefficient Operating Region

    CERN Document Server

    Asimakopoulos, Panagiotis; Bongiorno, M; Thiringer, T

    2016-01-01

    This work investigates the current sharing effect of a high power Soft Punch Through IGBT module in the Negative Temperature Coefficient region. The unbalanced current sharing between two of the substrates is demonstrated for different current and temperature levels and its impact on the thermal stressing of the device is evaluated. The results indicate that the current asymmetry does not lead to a significant thermal stressing unbalance between the substrates.

  14. Social Site Characterisation for CO2 storage operations to inform public engagement in Poland and Scotland

    Energy Technology Data Exchange (ETDEWEB)

    Brunsting, S.; Pol, M.; Mastop, J. [Energy research Centre of the Netherlands ECN, Policy Studies, Petten (Netherlands); Kaiser, M.; Zimmer, R. [UfU - Independent Institute for Environmental Issues, Berlin (Germany); Shackley, S.; Mabon, L.; Howell, R. [The University of Edinburgh - School of Geosciences, Edinburgh, Scotland (United Kingdom); Hepplewhite, F.; Loveridge, R. [Scottish Government, Edinburgh, Scotland (United Kingdom); Mazurowski, M. [PGNiG - Polskie Gornictwo Naftowe i Gazownictwo SA, Warszawa (Poland); Rybicki, C. [AGH - University of Science and Technology, Krakow (Poland)

    2013-05-01

    Public support has proven crucial to the implementation of CO2 capture and storage (CCS) demonstration projects. Whereas no method exists to guarantee local public acceptability of any project, a constructive stakeholder engagement process does increase the likelihood thereof. Social site characterisation can be used as an instrument to plan and evaluate an approach for actively engaging local stakeholders. Social site characterisation is the process of repeatedly investigating local public awareness and opinions of a specific CCS project, changes therein over time, and underlying factors shaping public opinion as a parallel activity to technical site characterization. This paper presents results from the EU FP7 SiteChar project in which social site characterisation (a.o. surveys) and public participation activities (focus conferences) were conducted by a multidisciplinary team at two prospective CCS sites in in Poland (onshore) and Scotland (offshore). Results demonstrate that social site characterization and focus conferences are powerful tools to raise public awareness about complex issues such as CCS and to initiate local discussion and planning processes with the appropriate type of information, through appropriate media, and involving all relevant stakeholders. Application and the duration of effects in real-life project settings will be discussed.

  15. Site environmental report for calendar year 2002. DOE operations at the Boeing Company, Rocketdyne Propulsion and Power

    Energy Technology Data Exchange (ETDEWEB)

    None

    2003-09-30

    This Annual Site Environmental Report (ASER) for 2002 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing' s Santa Susana Field Laboratory (SSFL)). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations at ETEC included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities at ETEC involved the operation of large-scale liquid metal facilities that were used for testing liquid metal fast breeder components. All nuclear work was terminated in 1988, and, subsequently, all radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2002 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property ( land, structures, waste), and recycling. All radioactive w astes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for radioactive waste disposal. No liquid radioactive wastes are released into the environment, and no structural debris from buildings w as transferred to municipal landfills or recycled in 2002.

  16. Environmental assessment for the expansion and operation of the Central Shops Borrow Pit at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-03-01

    The Department of Energy (DOE) prepared this Environmental Assessment (EA) to assess the potential environmental impacts of the proposed expansion and operation of an existing borrow pit at the Savannah River Site (SRS), located near Aiken, South Carolina. A borrow pit is defined as an excavated area where material has been dug for use as fill at another location. The proposed action would entail the areal enlargement, continued operation, and eventual close-out of the established facility known as the Central Shops Borrow Pit. Operations at SRS supporting waste site closure and the construction and maintenance of site facilities and infrastructure require readily available suitable soil for use as fill material. With the recent depletion of the other existing on-site sources for such material, DOE proposes to expand the existing facility. The National Environmental Policy Act requires the assessment of environmental consequences of Federal actions that may affect the quality of the human environment. Based on the potential for impacts described herein, DOE will either publish a Finding of No Significant Impact or prepare an Environmental Impact Statement (EIS).

  17. Marines in the Boxer Rebellion as a Model for Current Marine Corps Operations

    Science.gov (United States)

    2016-06-10

    Security Group ....................................................................... 45 Marine Corps Operations during the Cold War ...47 vii Post- Cold War Operations...naval gun crews in most of the major naval battles of the war .17 After the Civil War , the Marine Corps returned to Asia in support of national

  18. Elastic electron-deuteron scattering and two-body current operators in the Light-Front Hamiltonian Dynamics

    CERN Document Server

    Frederico, Tobias; Pace, Emanuele; Salme`, Giovanni

    2010-01-01

    The electromagnetic properties of the deuteron are investigated within a Light-Front Hamiltonian Dynamics framework, with a current operator that contains both one-body and two-body contributions. In this work, we are considering new two-body contributions, with a dynamical nature generated within a Yukawa model and a structure inspired by a recent analysis of the current operator, that acts on the three-dimensional valence component and fulfills the Ward-Takahashi identity. Preliminary results for the magnetic moment are shown.

  19. An Inferential System for Determination of Candidate Crash Sites for Search and Rescue Operations Project

    Data.gov (United States)

    National Aeronautics and Space Administration — We propose to develop, test, and prove the feasibility of a methodology for an inferential system for the generation of crash site likelihood maps. These maps will...

  20. Site Environmental Report for Calendar Year 2013. DOE Operations at The Boeing Company, Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    None

    2014-06-30

    This Annual Site Environmental Report (ASER) for 2013 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of the Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2013 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling. Due to the suspension of D&D activities in Area IV, no effluents were released into the atmosphere during 2013. Therefore, the potential radiation dose to the general public through airborne release was zero. Similarly, the radiation dose to an offsite member of the public (maximally exposed individual) due to direct radiation from SSFL is indistinguishable from background. All radioactive wastes are processed for disposal at DOE disposal sites and/or other licensed sites approved by DOE for radioactive waste

  1. Dependence of a railgun operation on a current rise time; Railgun dosa no kudo denryu tachiagari izonsei

    Energy Technology Data Exchange (ETDEWEB)

    Katsuki, S.; Sueda, T.; Akiyama, H. [Kumamoto University, Kumamoto (Japan). Faculty of Engineering

    1997-08-20

    Railguns are facilities to accelerate projectiles up to several km/s by the electromagnetic force due to a driving current. A variety of current waveforms are used for railguns developed in the world. This paper describes the dependence of a railgun operation on a rising rate of the driving current. The use of the exploding wire as an opening switch enables to change the rise time of the driving current. A secondary arc is likely to appear and the erosion on a rail surface is more severe when the current with a short rise time is used. According to the non-dimensional railgun plasma simulation, the current with a short rise time heats up the plasma so fast that plenty of particles ablated from the bore surface, which seem to be the cause of the secondary arc, increase rapidly in the early phase of acceleration. 18 refs., 14 figs.

  2. (Unsupported Current Tourism Development in UNESCO Protected Site: The Case of Old City of Dubrovnik

    Directory of Open Access Journals (Sweden)

    Ivana Pavlić

    2017-03-01

    Full Text Available The main purpose of this paper is to explore and determine perceptions of residents living in the United Nations Educational, Scientific and Cultural Organization (UNESCO protected site Old City of Dubrovnik (OCD towards tourism development. Uncontrolled tourism expansion has impact on local residents’ life and on their (unsupport for specific form of tourism development. Comprehension of residents’ perceptions is crucial for realization of adequate tourism development and for mutual satisfaction of tourism demand and supply. Therefore, the aim is to test the model of residents’ perceptions of economic, socio-cultural and environmental impacts of tourism on their (unsupport for specific form of tourism development. To realize the purpose of this research, Cronbach alpha, explorative (EFC and confirmatory (CFA factor analysis, and structural equation modeling (SEM were applied. The findings indicate that there is a direct relationship between residents who perceive positive and negative economic, socio-cultural and environmental impacts of tourism and their (unsupport for tourism development. This paper points out the role and significance of the permanent residents’ perceptions research concerning the issues that are related to the quality tourism development due to the high interaction between local residents, tourists and local tourism development especially in the areas under the protection of UNESCO.

  3. Site Environmental Report For Calendar Year 2012. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Dassler, David [The Boeing Company, Canoga Park, CA (United States)

    2013-09-01

    This Annual Site Environmental Report (ASER) for 2012 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2012 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  4. Site Environmental Report for Calendar Year 2011. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Dassler, David [The Boeing Company, Canoga Park, CA (United States)

    2012-09-01

    This Annual Site Environmental Report (ASER) for 2011 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2011 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  5. Industrial hygiene support of underground operations at the Nevada Test Site. Progress report, July 1, 1989--June 30, 1991

    Energy Technology Data Exchange (ETDEWEB)

    Porter, P.F.

    1992-07-23

    The Industrial Hygiene Section of the Health Protection Department provides industrial hygiene support of underground operations at the Nevada Test Site. This report describes support operations and summarizes the industrial hygiene data collected from July 31, 1989 through June 30, 1991. Air quality data were collected by means of personnel sampling by active and passive techniques using various kinds of industrial hygiene instrumentation and through localized and general area monitoring. The data collected were used to evaluate underground air quality and quantity requirements; evaluate worker exposures to a variety of air contaminants; determine the applicability and effectiveness of personal protective equipment.

  6. Additive Manufacturing (AM) in Expeditionary Operations: Current Needs, Technical Challenges, and Opportunities

    Science.gov (United States)

    2016-06-01

    It is also in the digital space that many of the issues and opportunities surrounding AM exist. Cyber security , the digital safeguarding of models and...Any discussion involving the digital space needs to include a discussion of security and operating in a hostile environment like the cyber world is...need to prepare for those operations by building and testing multiple iterations of draft 3D model repositories. Cyber - security will have to be woven

  7. One-loop renormalization of fermionic currents with the overlap-Dirac operator

    CERN Document Server

    Alexandrou, C; Panagopoulos, H; Vicari, E

    2000-01-01

    We compute the one-loop lattice renormalization of the two-quark operators$\\bar{\\psi} \\Gamma \\psi$, where $\\Gamma$ denotes the generic Dirac matrix, forthe lattice formulation of QCD using the overlap-Dirac operator. We also study the renormalization of quark bilinears which are more extendedand have better chiral properties. Finally, we present improved estimates of these renormalization constants,coming from cactus resummation and from mean field perturbation theory.

  8. Current implementation of site-specific technologies in U.S. cotton production

    Science.gov (United States)

    Barnes, Edward M.

    2004-11-01

    The initial adoption of site-specific management for cotton production was slower than by commodities grown in the mid-west. Part of the delayed adoption can be explained by the lack of functional cotton yield monitors. Now that yield monitors are commercially available, cotton producers are beginning to find many applications for geospatial technologies. The emphasis of this paper is on applications that are being implemented at some level on commercial farms. Traditional grid-based soil sampling has found some use for pre-plant application of fertilizer, and soil conductivity mapping has been used to apply variable rate soil amendments in the west. During the growing season, vegetation indices such as the normalized difference vegetation index (NDVI) have been used as a tool to direct scouting for insect infestations. The scouting information and NDVI are combined to create variable rate insecticide application maps. A catalyst to this approach has been the recent development of aerial variable rate application technology. In some production regions, it is necessary to control cotton's vegetative development rate with plant growth regulators (PGRs). Vegetation indices are very useful for defining areas of the field where PGRs are needed. Research is also being conducted on the use of imagery for the development of defoliation application maps before harvest. In the short-term, simple vegetation indices can meet many of management information needs for cotton when combined with directed scouting of the field. However, to be ultimately successful, dependable and frequent sources of imagery will be required. Near-real time delivery is essential, as a majority of the management decisions are often made on a daily basis. Most producer-based applications of these data have been from airborne platforms managed by local image providers where flexible image acquisition schedules are possible.

  9. The Use of Dexamethasone in Support of High-Altitude Ground Operations: Review of the Literature & Current Training of U.S. Special Operations Medical Members

    Science.gov (United States)

    2013-03-14

    8) 8 mg twice daily starting the day before the ascent to 4,559 m throughout the 2-day study Dexamethasone improved VO2 - max (pɘ.05) and...4,559 m Dexamethasone improved VO2 - max (p=0.025); no significant difference existed in arterial O2 saturation during maximal exercise...AFRL-SA-WP-SR-2013-0006 The Use of Dexamethasone in Support of High-Altitude Ground Operations: Review of the Literature & Current

  10. Transcriptional pausing at the translation start site operates as a critical checkpoint for riboswitch regulation

    Science.gov (United States)

    Chauvier, Adrien; Picard-Jean, Frédéric; Berger-Dancause, Jean-Christophe; Bastet, Laurène; Naghdi, Mohammad Reza; Dubé, Audrey; Turcotte, Pierre; Perreault, Jonathan; Lafontaine, Daniel A.

    2017-01-01

    On the basis of nascent transcript sequencing, it has been postulated but never demonstrated that transcriptional pausing at translation start sites is important for gene regulation. Here we show that the Escherichia coli thiamin pyrophosphate (TPP) thiC riboswitch contains a regulatory pause site in the translation initiation region that acts as a checkpoint for thiC expression. By biochemically probing nascent transcription complexes halted at defined positions, we find a narrow transcriptional window for metabolite binding, in which the downstream boundary is delimited by the checkpoint. We show that transcription complexes at the regulatory pause site favour the formation of a riboswitch intramolecular lock that strongly prevents TPP binding. In contrast, cotranscriptional metabolite binding increases RNA polymerase pausing and induces Rho-dependent transcription termination at the checkpoint. Early transcriptional pausing may provide a general mechanism, whereby transient transcriptional windows directly coordinate the sensing of environmental cues and bacterial mRNA regulation. PMID:28071751

  11. Operational Circular No.2 (Rev. 2) - Conditions of access to the fenced parts of the CERN site

    CERN Multimedia

    2014-01-01

    Operational Circular No. 2 (Rev. 2) entitled “Conditions of access to the fenced parts of the CERN site” and its “implementation measures”, approved by the Director-General following discussion at the Standing Concertation Committee meeting on 20 May 2014 and entering into force on 1 September 2014, are available on the intranet site of the Human Resources Department (see here).   This circular is applicable to members of the personnel and other persons concerned. It cancels and replaces Operational Circular No. 2 (Rev. 1) entitled “Conditions of access to the fenced parts of the CERN site”, of April 1998. In particular, the revised circular provides for the possibility of mandating a person responsible for the proper implementation of the circular, specifies the rules relating to vehicles allowed on the site and the respective responsibilities of their owners, and relaxes certain administrative formalities in case of loss, theft or di...

  12. Pre-operative patient preparation in the prevention of surgical site infections.

    Science.gov (United States)

    McBride, Tara; Beamer, Jennifer

    2007-12-01

    In 1999 the Ontario Ministry of Health and Long-Term Care granted funding to St. Mary's General Hospital for a Regional Cardiac Care Center. In July 2003 the cardiac surgery program opened. During the program-planning phase, protocols and procedures related to patient preparation for cardiac surgery were developed. To share policies, protocols and patient teaching tools developed from research driven, evidenced based standards of practice. To complete a one-year review (January to December 2004) and assess the compliance rates with pre-operative patient preparation procedures on all Coronary Artery Bypass Graft (CABG) cardiac surgery patients. Retrospective chart review. 191 bed community-based Regional Cardiac Care Centre. All adult patients undergoing Coronary Artery Bypass Graft (CABG) surgery from January 1st 2004 to December 31st 2004. Compliance rate following patient education related to pre-operative washes, assessing completion of pre-operative washes, and location of clipping relative to the Cardiovascular Operating Room (CVOR). A team of Registered Nurses was able to effectively implement policies and protocols within a cardiac surgery program that meet the recommended standards of care of the Centers for Disease Control and Prevention (CDC), Operating Room Nurses Association of Canada (ORNAC) and Safer Health Care Now! Initiative. A retrospective chart review has demonstrated that staff consistently apply and document care in accordance with the developed pre-operative wash and hair clipping protocols.

  13. Direct Experimental Evidence for Current-Transfer Mode Operation of Nested Tungsten Wire Arrays at 16 19 MA

    Science.gov (United States)

    Cuneo, M. E.; Sinars, D. B.; Bliss, D. E.; Waisman, E. M.; Porter, J. L.; Stygar, W. A.; Lebedev, S. V.; Chittenden, J. P.; Sarkisov, G. S.; Afeyan, B. B.

    2005-06-01

    Nested tungsten wire arrays (20-mm on 12-mm diam.) are shown for the first time to operate in a current-transfer mode at 16 19 MA, even for azimuthal interwire gaps of 0.2 mm that are the smallest typically used for any array experiment. After current transfer, the inner wire array shows discrete wire ablation and implosion characteristics identical to that of a single array, such as axially nonuniform ablation, delayed acceleration, and trailing mass and current. The presence of trailing mass from the outer and the inner arrays may play a role in determining nested array performance.

  14. Current status of natural orifice trans-endoscopic surgery (NOTES and laparoendoscopic single site surgery (LESS in urologic surgery

    Directory of Open Access Journals (Sweden)

    Rafael E. Sanchez-Salas

    2010-08-01

    Full Text Available Laparoendoscopic single site surgery (LESS and natural orifice transluminal endoscopic surgery (NOTES represent novel approaches in urological surgery. To perform a review of the literature in order describe the current status of LESS and NOTES in Urology. References for this manuscript were obtained by performing a review of the available literature in PubMed from 01-01-02 to 15-05-09. Search terms included single port, single site, NOTES, LESS and single incision. A total of 412 manuscripts were initially identified. Out of these, 64 manuscripts were selected based in their urological content. The manuscript features subheadings for experimental and clinical studies, as NOTES-LESS is a new surgical technique and its future evolution will probably rely in initial verified feasibility. A subheading for reviews presents information regarding common language and consensus for the techniques. The issue of complications published in clinical series and the future needs of NOTES-LESS, are also presented.

  15. How to open & operate a financially successful web site design business

    CERN Document Server

    Evans, Charlotte

    2009-01-01

    The Pricing & Ethical Guidelines Handbook published by the Graphic Arts Guild reports that the average cost of designing a Web site for a small corporation can range from 7,750 to 15,000. It is incredibly easy to see the enormous profit potential. Web design businesses can be run part- or full-time and can easily be started in your own home. As such, they are one of the fastest growing segments of the Internet economy. Here is the manual you need to cash in on this highly profitable segment of the industry. This book is a comprehensive and detailed study of the business side of Web site des

  16. Defense Logistics: Actions Needed to Improve the Availability of Critical Items during Current and Future Operations

    Science.gov (United States)

    2005-04-01

    and aluminium oxide. The tile is backed by multiple layers of polyethylene fiber. 2 Additional attachments include throat and groin protectors...20548 To order by Phone: Voice: (202) 512-6000 TDD: (202) 512-2537 Fax: (202) 512- 6061 Contact: Web site: www.gao.gov/fraudnet/fraudnet.htm E

  17. Role of recipient-site preparation techniques and post-operative wound dressing in the surgical management of vitiligo

    Directory of Open Access Journals (Sweden)

    Nour Al-Hadidi

    2015-01-01

    Full Text Available Vitiligo is an acquired skin disorder characterized by the destruction of melanocytes resulting in achromic macules and patches involving the affected skin. Multiple methods of treatments have emerged to manage vitiligo, including medical and surgical techniques. Among the surgical techniques described in the management of vitiligo are minipunch grafting, split-thickness skin grafting, hair follicle transplantation, suction blister grafting, and cultured and non-cultured autologous melanocyte transplantation. However, prior to grafting optimal recipient-site preparation is needed for graft survival and successful repigmentation outcomes. Similarly, post-operative care of the recipient site is vital to yielding a viable graft irrespective of the transplantation technique employed. This article reviews the multiple methods employed to prepare the recipient site in vitiligo surgeries and the post-surgical conditions which optimize graft viability. A pubmed search was conducted utilizing the key words listed below.

  18. Full Life Cycle Research at the Ketzin Pilot Site, Germany - From Safe and Successful CO2 Injection Operation to Post-Injection Monitoring and Site Closure

    Science.gov (United States)

    Liebscher, A. H.

    2016-12-01

    The Ketzin pilot site near Berlin, Germany, was initiated in 2004 as the first European onshore storage project for research and development on geological CO2 storage. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into a saline aquifer (Upper Triassic sandstone) at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section; full abandonment of this well finished in 2015 after roughly 2 years of well closure monitoring. Abandonment of the remaining 4 wells will be finished by 2017 and hand-over of liability to the competent authority is planned for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the pilot capture facility "Schwarze Pumpe" (oxyfuel power plant CO2 with purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40 - 45°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and temporal in-reservoir behaviour of the injected CO2 even for small quantities. After the cessation of CO2 injection, post-injection monitoring continued and two additional

  19. 36 CFR 6.4 - Solid waste disposal sites not in operation on September 1, 1984.

    Science.gov (United States)

    2010-07-01

    ... treatment plant, septic system waste, or domestic sewage; (vii) Petroleum, including used crankcase oil from... Places, or a road designated as open to public travel; (11) The site will receive less than 5 tons per...; (2) The name and legal addresses of the following: (i) Owners of record of the land; and (ii) Any...

  20. Review of Current Data Exchange Practices: Providing Descriptive Data to Assist with Building Operations Decisions

    Energy Technology Data Exchange (ETDEWEB)

    Livingood, W.; Stein, J.; Considine, T.; Sloup, C.

    2011-05-01

    Retailers who participate in the U.S. Department of Energy Commercial Building Energy Alliances (CBEA) identified the need to enhance communication standards. The means are available to collect massive numbers of buildings operational data, but CBEA members have difficulty transforming the data into usable information and energy-saving actions. Implementing algorithms for automated fault detection and diagnostics and linking building operational data to computerized maintenance management systems are important steps in the right direction, but have limited scalability for large building portfolios because the algorithms must be configured for each building.

  1. Groundwater science in water-utility operations: global reflections on current status and future needs

    Science.gov (United States)

    Foster, Stephen; Sage, Rob

    2017-08-01

    The relevance of groundwater science to water-utility operations is analysed from a broad international perspective, identifying key concerns and specific opportunities for the future. The strategic importance worldwide of water utilities assuming the role of lead stakeholders for integrated groundwater resource management, recognizing their often considerable technical know-how and highly significant data holdings, is emphasized. Concurrently, the utilities themselves will need an ever-closer appreciation of groundwater-system behaviour if they are to manage efficiently their water-supply and wastewater operations.

  2. The balanced scorecard advantage: Driving strategic change into Canada's nuclear laboratory site operations

    Energy Technology Data Exchange (ETDEWEB)

    Lafreniere, P. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Weeks, D. [Haggarty' s Cove Ventures (2001 Ltd.) St. Stephen, New Brunswick (Canada)

    2001-07-01

    The challenges presented by the size, diversity, complexity and history of the Facilities and Nuclear Operations (FNO) Group at AECL's Chalk River Laboratories (CRL) required a change to the traditional management approach. As a result, a strategy was adopted that focused on integrating contemporary business practices such as process mapping, activity based management and use of the Balanced Scorecard methodology into the operational culture at CRL. In addition, revitalization of the performance management methods process was undertaken to provide a tool for assessment of business and individual performance. performance. (author)

  3. Site Environmental Report for Calendar Year 2009. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Amar, Ravnesh [The Boeing Company, Canoga Park, CA (United States)

    2010-09-01

    This Annual Site Environmental Report (ASER) for 2009 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2009 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  4. Site Environmental Report for Calendar Year 2010. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Amar, Ravnesh [The Boeing Company, Canoga Park, CA (United States)

    2011-09-01

    This Annual Site Environmental Report (ASER) for 2010 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program for the calendar year 2010 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  5. Site Environmental Report for Calendar Year 2008. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Amar, Ravnesh [The Boeing Company, Canoga Park, CA (United States)

    2009-09-01

    This Annual Site Environmental Report (ASER) for 2008 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). The Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. In May 2007, the D&D operations in Area IV were suspended by the DOE. The environmental monitoring programs were continued throughout the year. Results of the radiological monitoring program for the calendar year 2008 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  6. Current status and science operations plan of BepiColombo MMO

    Science.gov (United States)

    Murakami, G.; Fujimoto, M.

    2016-12-01

    BepiColombo is an ESA-JAXA joint mission to Mercury with the aim to understand the process of planetary formation and evolution as well as to understand similarities and differences between the magnetospheres of Mercury and Earth. The baseline mission consists of two spacecraft, i.e. the Mercury Planetary Orbiter (MPO) and the Mercury Magnetospheric Orbiter (MMO). The two orbiters will be launched in 2018 by an Ariane-5 and arrive at Mercury in 2024. Being a spin-stabilized spacecraft, MMO has much less constraint for plasma observations and is expected to extract essential elements of space plasma physics that become visible in the Hermean environment. JAXA is responsible for the development and operations of MMO, and it's almost ready for launch. Therefore, now we can concentrate on preparing the science operations plans. MMO has large constraints on science operations, such as thermal issue and limited telemetry rate. Due to the thermal issue each science instrument cannot always be turned on. In addition, due to the low telemetry rate in average, only a part ( 20-30%) of science mission data with high resolution can be downlinked. Therefore, in order to maximize the scientific results and outcomes to be achieved by MMO, we must optimize the science observation and downlink plans in detail. In this paper, we introduce the science objectives, operations strategies and plans of MMO.

  7. Kansas State University DOE/KEURP Site Operator User Task Force

    Science.gov (United States)

    Hague, J.

    1994-06-01

    This program relates to demonstration use of electric-powered vehicles. KSU has two electric cars (conversion vehicles) from Soleq. Corp., and is purchasing 4 Chevy trucks for conversion. This document discusses the participating groups, program plan, events, vehicles and components, operations, and procurement.

  8. An Overview of Current Capabilities and Research Activities in the Airspace Operations Laboratory at NASA Ames Research Center

    Science.gov (United States)

    Prevot, Thomas; Smith, Nancy M.; Palmer, Everett; Callantine, Todd; Lee, Paul; Mercer, Joey; Homola, Jeff; Martin, Lynne; Brasil, Connie; Cabrall, Christopher

    2014-01-01

    The Airspace Operations Laboratory at NASA Ames conducts research to provide a better understanding of roles, responsibilities, and requirements for human operators and automation in future air traffic management (ATM) systems. The research encompasses developing, evaluating, and integrating operational concepts and technologies for near-, mid-, and far-term air traffic operations. Current research threads include efficient arrival operations, function allocation in separation assurance and efficient airspace and trajectory management. The AOL has developed powerful air traffic simulation capabilities, most notably the Multi Aircraft Control System (MACS) that is used for many air traffic control simulations at NASA and its partners in government, academia and industry. Several additional NASA technologies have been integrated with the AOL's primary simulation capabilities where appropriate. Using this environment, large and small-scale system-level evaluations can be conducted to help make near-term improvements and transition NASA technologies to the FAA, such as the technologies developed under NASA's Air Traffic Management Demonstration-1 (ATD-1). The AOL's rapid prototyping and flexible simulation capabilities have proven a highly effective environment to progress the initiation of trajectory-based operations and support the mid-term implementation of NextGen. Fundamental questions about accuracy requirements have been investigated as well as realworld problems on how to improve operations in some of the most complex airspaces in the US. This includes using advanced trajectory-based operations and prototype tools for coordinating arrivals to converging runways at Newark airport and coordinating departures and arrivals in the San Francisco and the New York metro areas. Looking beyond NextGen, the AOL has started exploring hybrid human/automation control strategies as well as highly autonomous operations in the air traffic control domain. Initial results

  9. Environmental Assessment for Operations, Upgrades, and Consolidation at the Western Command Site, New Mexico

    Science.gov (United States)

    2014-09-01

    the use of the proposed Western Secure Transportation Center would improve the health and safety of OST personnel, resulting in long-term, beneficial...and fall within the permitted maximum. The construction and use of the proposed Western Secure Transportation Center would improve the health and...munitions. All agents that are not on mission status would train at the PT/IUF building at least 3 hours daily rather than use an off-site gym . No Action

  10. Good Seeing: Best Practices for Sustainable Operations at the Air Force Maui Optical and Supercomputing Site

    Science.gov (United States)

    2016-01-01

    instrument switching capabilities, a steady stream of telemetry must be supplied by detectors and actuators situated at all points of possible failure...remote staff must have constant access to this telemetry . The telescope must be able to be opened and closed remotely, and weather changes must be...and narrow-field facilities rarely occupy the same site, so this dual capacity is part of AMOS’s unique value proposition. 3 Since AFRL took over

  11. Yearlong moored bioluminescence and current data at KM3NeT neutrino telescope sites in the deep Ionian Sea

    Science.gov (United States)

    van Haren, Hans; de Jong, Maarten; Kooijman, Paul

    2015-07-01

    Yearlong observations are presented using stand-alone small optical sensors and current meters in the deep Ionian Sea, E-Mediterranean. At two future neutrino telescope sites, off Sicily (I) and off Peloponessos (Gr), we deployed 2500-3000 m long mooring lines with oceanographic instrumentation. At about 150 m above the sea-floor, a glass sphere was mounted to each line holding two 3″-diameter photo-multiplier-tubes 'PMTs' in opposing directions for a first deep-sea test. Due to technical problems the background optical count rate could not be well established. Here, the focus is on the variations with time of bioluminescence bursts and their correlation with currents. Spectral analysis demonstrates that the PMT data best resemble those of horizontal currents (kinetic energy), significantly peaking at near-inertial, sub-inertial mesoscale and (Gr only) at tidal frequencies. Out-of-phase differences between signals from opposing PMTs in the same optical unit indicate impacts of bioluminescent organisms as a function of current direction, rather than a bacterial glow constant with time.

  12. High or low-side solid state relay with current limiting and operational testing

    Science.gov (United States)

    Dolland, C. R.

    1984-07-01

    The switch comprises a circuit from a first output terminal via parallel MOS devices in series with current-sensing resistance to a second output terminal, with alternative high-side and low-side configurations having a load between the second terminal and ground, or the first terminal and the DC supply voltage. An input terminal for a digital control signal is coupled via an input diode and two Schmitt Trigger CMOS inverters to a control lead for the gates of the switch. A current overload or short circuit protection circuit coupled between the current-sensor and the input diode comprises two transistors coupled by a diode. A built-in test circuit for indicating the switch condition (on, off, shorted or open) comprises MOS transistors having their gates connected to voltage dividers at the two output terminals, and their drains connected to discrete indication terminals.

  13. Current Practices in Global/International Advanced Pharmacy Practice Experiences: Home/Host Country or Site/Institution Considerations.

    Science.gov (United States)

    Alsharif, Naser Z; Dakkuri, Adnan; Abrons, Jeanine P; Williams, Dennis; Ombengi, David N; Zheng, HaiAn; Al-Dahir, Sara; Tofade, Toyin; Gim, Suzanna; O'Connell, Mary Beth; Ratka, Anna; Dornblaser, Emily

    2016-04-25

    International outreach by schools and colleges of pharmacy is increasing. In this paper, we provide current practice guidelines to establish and maintain successful global/international advanced pharmacy practice experiences (G/I APPEs) with specific recommendations for home/host country and host site/institution. The paper is based on a literature review (2000-2014) in databases and Internet searches with specific keywords or terms. Educational documents such as syllabi and memoranda of understanding (MoUs) from pharmacy programs were also examined. In addition, a preliminary draft was developed and the findings and recommendations were reviewed in a 90-minute roundtable discussion at the 2014 American Association of Colleges of Pharmacy Annual Meeting. Recommendations for the host country include travel considerations (eg, passport, visa, air travel), safety, housing, transportation, travel alerts and warnings, health issues, and financial considerations. For the home country, considerations for establishment of G/I APPE site (eg, vetting process, MoU, site expectations) are described. The paper is a resource for development of new G/I APPEs and provides guidance for continuous quality improvement of partnerships focusing on G/I pharmacy education.

  14. Baseline risk assessment for the quarry residuals operable unit of the Weldon Spring Site, Weldon Spring, Missouri

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-02-01

    The U.S. Department of Energy (DOE) is conducting cleanup activities at the Weldon Spring site, located in St. Charles County, Missouri, about 48 km (30 mi) west of St. Louis. Cleanup of the site consists of several integrated components. The quarry residuals operable unit (QROU), consisting of the Weldon Spring quarry and its surrounding area, is one of four operable units being evaluated. In accordance with requirements of the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), as amended, DOE is conducting a remedial investigation/feasibility study (RI/FS) to determine the proper response to address various contaminated media that constitute the QROU. Specifically, the operable unit consists of the following areas and media: the residual material remaining at the Weldon Spring quarry after removal of the pond water and the bulk waste; groundwater underlying the quarry and surrounding area; and other media located in the surrounding vicinity of the quarry, including surface water and sediment at Femme Osage Slough, Little Femme Osage Creek, and Femme Osage Creek. An initial evaluation of conditions at the quarry area identified remaining data requirements needed to support the conceptual site exposure and hydrogeological models. These data requirements are discussed in the RI/FS work plan issued in January 1994. Soil contamination located at a property adjacent to the quarry, referred to as Vicinity Property 9 (VP9), was originally part of the scope of the QROU, as discussed in the work plan. However, a decision was subsequently made to remediate this vicinity property as part of cleanup activities for the chemical plant operable unit, as provided for in the Record of Decision (ROD). Remediation of VP9 was completed in early 1996. Hence, this baseline risk assessment (BRA) does not address VP9.

  15. The role of historical operations information for supporting remedial investigation work at the former Harshaw Chemical Site - 8279.

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, R.; Peterson, J.; Picel, K.; Kolhoff, A.; Devaughn, J.; Environmental Science Division; U. S.Army Corps of Engineers, Buffalo District; Science Applications International Corp.

    2008-01-01

    potential COI associated with recycled uranium and contaminant locations that were inconsistent with the original CSM. As part of an RI Addendum effort, the USACE reconsidered its understanding of HCS historical activities. This effort included an intensive review of available historical aerial photography, an in-depth Potentially Responsible Parties (PRP) investigation, additional analysis of the production processes in place at HCS, and targeted supplemental data collection. The result of this effort was a revised CSM that included a number of previously unidentified potential COI and a much clearer understanding of the processes and resulting waste streams potentially associated with environmental contamination. Because of their complex and often poorly documented operational histories, unexpected discoveries will always be a part of investigating sites such as HCS. Taking advantage of available resources and expending funds for thorough historical research early in the life of a project will help to reduce the chances for expensive field remobilizations and significant schedule delays. A complete and accurate site history also allows for more efficient long-term technical and budgetary planning, thus eliminating many obstacles associated with the ultimate disposition of HTRW sites.

  16. Feasibility study for remedial action for the Quarry Residuals Operable Unit at the Weldon Spring Site, Weldon Spring, Missouri

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-03-01

    The U.S. Department of Energy (DOE) is conducting cleanup activities at the Weldon Spring site, which is located in St. Charles County, Missouri, about 48 km (30 mi) west of St. Louis (Figure 1.1). Cleanup of the Weldon Spring site consists of several integrated components. The quarry residuals operable unit (QROU) is one of four operable units being evaluated. In accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), as amended, a remedial investigation/feasibility study (RI/FS) is being conducted to evaluate conditions and potential responses for the following areas and/or media that constitute the QROU: (1) the residual material (soil and sediment) remaining at the Weldon Spring quarry after removal of the bulk waste (about 11 million L [3 million gal] of uranium-contaminated ponded water was also addressed previous to bulk waste removal); (2) other media located in the surrounding vicinity of the quarry, including adjacent soil, surface water, and sediment in Femme Osage Slough and several creeks; and (3) quarry groundwater located primarily north of Femme Osage Slough. Potential impacts to the St. Charles County well field downgradient of the quarry area are also being addressed as part of QROU RI/FS evaluations. For remedial action sites, it is DOE policy to integrate values associated with the National Environmental Policy Act (NEPA) into the CERCLA decision-making process. The analyses contained herein address NEPA values as appropriate to the actions being considered for the QROU. A work plan summarizing initial site conditions and providing conceptual site hydrogeological and exposure models was published in January 1994. The RI and baseline risk assessment (BRA) reports have been completed. The RI discusses in detail the nature and extent and the fate and transport of contamination at the quarry area.

  17. Killing of a King: The Increasing Marginalization of the Field Artillery Branch in Current Counterinsurgency Operations

    Science.gov (United States)

    2010-06-11

    Unfortunately, today this is still the case , high operational deployment and training cycles prevent the FA officers and Soldiers from mastering...an axe to grind or a hidden agenda behind this thesis, but that is not the case . Identifying and studying problems is exactly what makes the FA branch...Readiness Training Center, LTC Daniel A. Pinnell and LTC Robert Morschauser some of the same observations that were pointed out in the white paper were

  18. Current and Planned High Proton Flux Operations at the FNAL Booster

    CERN Document Server

    Garcia, F G

    2014-01-01

    The Fermilab Proton Source machines, constituted by Pre-Injector, conventional Linac and Booster synchrotron, at Fermi National Accelerator Laboratory (Fermilab) had have a long history of successful beam operations. Built in late '60s, the Fermilab Proton Source began operations early in the '70s and since then it has successful provided protons to support the laboratory physics experiments. During the past decade, Booster performance reached unprecedented proton flux delivery of the order of 1.0-1.1E17 protons per hour, corresponding to 40 kW of beam power while maintained an allowed upper limit of 525 W of beam loss in the tunnel. In order to achieve this historical performance, major hardware upgrades were made in the machine combined with improvements in beam orbit control and operational awareness. Once again, the Proton Source has been charged to double their beam throughput, while maintaining the present residual activation levels, to meet the laboratory Intensity Frontier program goals until new mach...

  19. Degradation of Solid Oxide Electrolysis Cells Operated at High Current Densities

    DEFF Research Database (Denmark)

    Tao, Youkun; Ebbesen, Sune Dalgaard; Mogensen, Mogens Bjerg

    2014-01-01

    In this work the durability of solid oxide cells for co-electrolysis of steam and carbon dioxide (45 % H2O + 45 % CO2 + 10 % H2) at high current densities was investigated. The tested cells are Ni-YSZ electrode supported, with a YSZ electrolyte and either a LSM-YSZ or LSCF-CGO oxygen electrode...

  20. The British Colonial Experience in Waziristan and Its Applicability to Current Operations

    Science.gov (United States)

    2007-11-02

    fall 2004, the Paksitani government used the same carrots and sticks that the British government used in the tribal areas from 1849-1947. The...limited and precise. (3) The U.S. and Pakistani cannot employ a cookie cutter solution to the current situation in Waziristan. Due to the complex and

  1. Operation of the DC current transformer intensity monitors at FNAL during run II

    Energy Technology Data Exchange (ETDEWEB)

    Crisp, J.; Fellenz, B.; Heikkinen, D.; Ibrahim, M.A.; Meyer, T.; Vogel, G.; /Fermilab

    2012-01-01

    Circulating beam intensity measurements at FNAL are provided by five DC current transformers (DCCT), one per machine. With the exception of the DCCT in the Recycler, all DCCT systems were designed and built at FNAL. This paper presents an overview of both DCCT systems, including the sensor, the electronics, and the front-end instrumentation software, as well as their performance during Run II.

  2. Plasma Shape and Current Density Profile Control in Advanced Tokamak Operating Scenarios

    Science.gov (United States)

    Shi, Wenyu

    The need for new sources of energy is expected to become a critical problem within the next few decades. Nuclear fusion has sufficient energy density to potentially supply the world population with its increasing energy demands. The tokamak is a magnetic confinement device used to achieve controlled fusion reactions. Experimental fusion technology has now reached a level where tokamaks are able to produce about as much energy as is expended in heating the fusion fuel. The next step towards the realization of a nuclear fusion tokamak power plant is ITER, which will be capable of exploring advanced tokamak (AT) modes, characterized by a high fusion gain and plasma stability. The extreme requirements of the advanced modes motivates researchers to improve the modeling of the plasma response as well as the design of feedback controllers. This dissertation focuses on several magnetic and kinetic control problems, including the plasma current, position and shape control, and data-driven and first-principles-driven modeling and control of plasma current density profile and the normalized plasma pressure ratio betaN. The plasma is confined within the vacuum vessel by an external electromagnetic field, produced primarily by toroidal and poloidal field coils. The outermost closed plasma surface or plasma boundary is referred to as the shape of the plasma. A central characteristic of AT plasma regimes is an extreme elongated shape. The equilibrium among the electromagnetic forces acting on an elongated plasma is unstable. Moreover, the tokamak performance is improved if the plasma is located in close proximity to the torus wall, which guarantees an efficient use of available volume. As a consequence, feedback control of the plasma position and shape is necessary. In this dissertation, an Hinfinity-based, multi-input-multi-output (MIMO) controller for the National Spherical Torus Experiment (NSTX) is developed, which is used to control the plasma position, shape, and X

  3. An operational amplifier B1404UD1A-1 in the patch-clamp current-to-voltage converter.

    Science.gov (United States)

    Korzun, A M; Rozinov, S V; Abashin, G I

    1997-01-01

    The applicability of the home-made operational amplifier B1404UD1A-1 in a patch-clamp current-to-voltage converter was analyzed. Its parameters (background noise, input bias current, and gain-bandwidth product) were estimated. Schematic solutions and practical recommendations for the use of this amplifier in a current-to-voltage converter were given. Based on the background noise and frequency parameters of the converter, we found that this device can be used for measuring ion channel currents with a high sensitivity and within a broad frequency range (0.055 pA, to 1 kHz; 0.4 pA, to 10 kHz). An example of the converter application in experiments is given.

  4. Crystallization in high level waste (HLW) glass melters: Savannah River Site operational experience

    Energy Technology Data Exchange (ETDEWEB)

    Fox, Kevin M. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Peeler, David K. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Kruger, Albert A. [USDOE Office of River Protection, Richland, WA (United States)

    2015-06-12

    This paper provides a review of the scaled melter testing that was completed for design input to the Defense Waste Processing Facility (DWPF) melter. Testing with prototype melters provided the data to define the DWPF operating limits to avoid bulk (volume) crystallization in the un-agitated DWPF melter and provided the data to distinguish between spinels generated by refractory corrosion versus spinels that precipitated from the HLW glass melt pool. A review of the crystallization observed with the prototype melters and the full-scale DWPF melters (DWPF Melter 1 and DWPF Melter 2) is included. Examples of actual DWPF melter attainment with Melter 2 are given. The intent is to provide an overview of lessons learned, including some example data, that can be used to advance the development and implementation of an empirical model and operating limit for crystal accumulation for a waste treatment and immobilization plant.

  5. Crystallization in high level waste (HLW) glass melters: Savannah River Site operational experience

    Energy Technology Data Exchange (ETDEWEB)

    Fox, K.

    2015-06-12

    This paper provides a review of the scaled melter testing that was completed for design input to the Defense Waste Processing Facility (DWPF) melter. Testing with prototype melters provided the data to define the DWPF operating limits to avoid bulk (volume) crystallization in the un-agitated DWPF melter and provided the data to distinguish between spinels generated by refractory corrosion versus spinels that precipitated from the HLW glass melt pool. A review of the crystallization observed with the prototype melters and the full scale DWPF melters (DWPF Melter 1 and DWPF Melter 2) is included. Examples of actual DWPF melter attainment with Melter 2 are given. The intent is to provide an overview of lessons learned, including some example data, that can be used to advance the development and implementation of an empirical model and operating limit for crystal accumulation for a waste treatment and immobilization plant.

  6. Physical activity in relation to all-site and lung cancer incidence and mortality in current and former smokers.

    Science.gov (United States)

    Alfano, Catherine M; Klesges, Robert C; Murray, David M; Bowen, Deborah J; McTiernan, Anne; Vander Weg, Mark W; Robinson, Leslie A; Cartmel, Brenda; Thornquist, Mark D; Barnett, Matt; Goodman, Gary E; Omenn, Gilbert S

    2004-12-01

    Increased physical activity has been associated with a reduction in the incidence and mortality from all-site cancer and some site-specific cancers in samples of primarily nonsmoking individuals; however, little is known about whether physical activity is associated with similar risk reductions among smokers and ex-smokers. This study examined physical activity in relation to all-site cancer and lung cancer incidence and mortality in a sample of current and former smokers (n = 7,045; 59% male; 95% Caucasian; mean age, 63 years) drawn from the beta-Carotene and Retinol Efficacy Trial, a lung cancer chemoprevention trial. Hazard rate ratios and 95% confidence intervals associated with a 1 SD increase in physical activity were 0.86 (0.80-0.94) for all-site cancer only among men, 0.84 (0.69-1.03) for lung cancer only for younger participants, 0.75 (0.59-0.94) for cancer mortality among younger participants and 0.68 (0.53-0.89) among women, and 0.69 (0.53-0.90) for lung cancer mortality only among women. These results suggest that incidence may be more attenuated by physical activity for men and mortality more attenuated for women. Effects may be more pronounced for younger people and may differ inconsistently by pack-years of smoking. Physical activity may play a role in reducing cancer risk and mortality among those with significant tobacco exposure. Prospective studies using more sophisticated measures of physical activity assessed at multiple time points during follow-up are needed to corroborate these associations.

  7. Annual report, August 1976--July 1977 Radiation dose to construction workers at operating nuclear power plant sites.

    Energy Technology Data Exchange (ETDEWEB)

    Endres, G.W.R.

    1978-01-01

    Radiation exposures received by most construction workers at nuclear power plant sites have not been measured routinely because field surveys have indicated exposure levels below the point for which monitoring is required. As a consequence, the dose to individuals and groups of workers is not known to the degree desired for adequate environmental impact assessment. This study was developed to measure and evaluate radiation exposure and exposure rates received by construction workers at various reactor sites where one or more reactors are operating while construction is proceeding on one or more additional reactors. This study is providing a data base from which a realistic assessment of radiological impact can be made for the construction workers of proposed multiunit nuclear power plants and to help arrive at a decision as to whether increased control of the radiation exposure of these workers is warranted. Four nuclear sites were included in this study after receiving approval of the operating utilities. Data from thermoluminescent personnel dosimeters and environmental dosimeters showed that the construction workers receive very little exposure above background.

  8. The Association Between Operating Room Personnel and Turnover With Surgical Site Infection in More Than 12 000 Neurosurgical Cases.

    Science.gov (United States)

    Wathen, Connor; Kshettry, Varun R; Krishnaney, Ajit; Gordon, Steven M; Fraser, Thomas; Benzel, Edward C; Modic, Michael T; Butler, Sam; Machado, Andre G

    2016-12-01

    Surgical site infection (SSI) contributes significantly to postoperative morbidity and mortality and greatly increases the cost of care. To identify the impact of workflow and personnel-related risk factors contributing to the incidence of SSIs in a large sample of neurological surgeries. Data were obtained using an enterprisewide electronic health record system, operating room, and anesthesia records for neurological procedures conducted between January 1, 2009, and November 30, 2012. SSI data were obtained from prospective surveillance by infection preventionists using Centers for Disease Control and Prevention definitions. A multivariate model was constructed and refined using backward elimination logistic regression methods. The analysis included 12 528 procedures. Most cases were elective (94.5%), and the average procedure length was 4.8 hours. The average number of people present in the operating room at any time during the procedure was 10.0. The overall infection rate was 2.3%. Patient body mass index (odds ratio, 1.03; 95% confidence interval [CI], 1.01-1.04) and sex (odds ratio, 1.36; 95% CI, 1.07-1.72) as well as procedure length (odds ratio, 1.19 per additional hour; 95% CI, 1.15-1.23) and nursing staff turnovers (odds ratio, 1.095 per additional turnover; 95% CI, 1.02-1.21) were significantly correlated with the risk of SSI. This study found that patient body mass index and male sex were associated with an increased risk of SSI. Operating room personnel turnover, a modifiable, work flow-related factor, was an independent variable positively correlated with SSI. This study suggests that efforts to reduce operating room turnover may be effective in preventing SSI. OR, operating roomSSI, surgical site infection.

  9. Operation of an efficient site-specific recombination system of Zygosaccharomyces rouxii in tobacco cells.

    Science.gov (United States)

    Onouchi, H; Yokoi, K; Machida, C; Matsuzaki, H; Oshima, Y; Matsuoka, K; Nakamura, K; Machida, Y

    1991-12-11

    Recombinase encoded by the R gene of pSR1 of Zygosaccharomyces rouxii mediates reciprocal recombination between two specific recombination sites (RSs) to induce excision or inversion of the DNA segment that is flanked by the RSs. We report here that site-specific recombination mediated by this system takes place effeciently in tobacco cells. To monitor the recombination events in tobacco cells, we have constructed two types of cryptic beta-glucuronidase reporter gene in such a way that recombination such as inversion of the construct or excision of the intervening sequence results in their expression. When these cryptic reporter constructs were transiently introduced together with the R gene by electroporation into protoplasts of tobacco cells, beta-glucuronidase activity was detected. The cryptic reporter genes, when stably resident in the chromosome of tobacco cells, were also activated by the R gene. Structural analyses of the genomic DNA isolated from these tobacco cells showed that the R protein did in fact catalyze precise recombination between two copies of RSs in tobacco cells, with resultant activation of the cryptic reporter genes. This observation provides the basis for development of a DNA technology whereby large regions of DNA can be manipulated in plant chromosomes. Potential uses of this recombination system are discussed.

  10. Fiscal year 1996 U.S. Department of Energy, Richland Operations Office Site summary baseline

    Energy Technology Data Exchange (ETDEWEB)

    Johndro-Collins, A.

    1995-10-01

    The technical baseline is a hierarchical description of the Hanford Site cleanup mission. This technical baseline does not address the science, technology, or economic transition missions. It begins with a definition of the existing conditions at the Hanford Site, provides a description of the end product or mission accomplishments at completion, presents a statement of the major requirements and constraints that must be observed during the performance of the mission, and provides a statement of the top-level strategic approach to accomplish the mission. Mission-level interfaces are also described. This information is further defined hierarchically in increasing levels of detail. This definition is composed of the following major elements: functions that are key task descriptions; requirements that are the measurable standards to which the functions must be performed; architectures which are specific engineering solutions or systems that perform the functions described earlier; and verification ensuring the system satisfies the requirements and fulfills the functions. The above information is supplemented with the following: interface data; risk analyses and watch lists; assumptions; and required analyses.

  11. Environmental Protection Department Operations and Regulatory Affairs Division Contingency Plan for Site 300 Waste Accumulation Area(s)

    Energy Technology Data Exchange (ETDEWEB)

    Levy, R

    2005-07-14

    This Contingency Plan identifies personnel responsibilities, emergency equipment, and required actions necessary to mitigate potential incidents at the Waste Accumulation Area(s) (WAA)(s) located at the Lawrence Livermore National Laboratory (LLNL) Experimental Test Site 300 (Site 300) as shown in Figure 1. This Plan is designed to prepare personnel to minimize hazards to human health and the environment from fires, explosions, or any sudden or nonsudden release of hazardous, radioactive, or mixed waste constituents to the air, ground surface, or water from waste stored in the WAA(s). The LLNL Site 300 currently has one WAA. The location of the WAA is shown in Figure 2 and identified in Table 1. As programmatic needs change, it may become necessary to establish additional WAAs at Site 300. The WAA is a small, regularly monitored storage area where waste can be accumulated and stored temporarily. Hazardous and mixed waste can be stored or accumulated in a WAA for up to 90 days, after which it must be transferred to a Department of Toxic Substances Control (DTSC) authorized onsite treatment or storage facility or an authorized offsite treatment, storage, or disposal facility (TSDF). The onsite TSDFs authorized by DTSC are managed by the Radioactive and Hazardous Waste Management (RHWM) Division and by the Chemistry and Materials Science Directorate (CMS) at Site 300. Hazardous, radioactive, or mixed waste is referred to as ''waste'' in this document. Radioactive waste has been included in this Plan as a ''Best Management Practice'' to aid in response, where appropriate. However, radioactive waste is not regulated by DTSC under this Plan. This Contingency Plan is divided into two parts: (1) The first part, referred to as the ''General Plan'', is general information that is applicable to the existing and any subsequent WAAs. The General Plan includes Sections 1-7 and Appendices A-C. (2) The second part

  12. Site Environmental Report for Calendar Year 2004. DOE Operations at The Boeing Company Santa Susana Field Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States); Lee, Majelle [The Boeing Company, Canoga Park, CA (United States)

    2005-09-01

    This Annual Site Environmental Report (ASER) for 2004 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2004 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  13. Site Environmental Report for Calendar Year 2006. DOE Operations at The Boeing Company Santa Susana Field Laboratory, Area IV

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Ning [The Boeing Company, Canoga Park, CA (United States); Rutherford, Phil [The Boeing Company, Canoga Park, CA (United States)

    2007-09-01

    This Annual Site Environmental Report (ASER) for 2006 describes the environmental conditions related to work performed for the Department of Energy (DOE) at Area IV of Boeing’s Santa Susana Field Laboratory (SSFL). In the past, the Energy Technology Engineering Center (ETEC), a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder components. All nuclear work was terminated in 1988; all subsequent radiological work has been directed toward decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Closure of the liquid metal test facilities began in 1996. Results of the radiological monitoring program for the calendar year 2006 continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  14. Renormalization of domain-wall bilinear operators with short-distance current correlators

    CERN Document Server

    Tomii, M; Fahy, B; Fukaya, H; Hashimoto, S; Kaneko, T; Noaki, J

    2016-01-01

    We determine the renormalization constants for flavor non-singlet fermion bilinear operators of M\\"obius domain-wall fermions. The renormalization condition is imposed on the correlation functions in the coordinate space, such that the non-perturbative lattice calculation reproduces the perturbatively calculated counterpart at short distances. The perturbative expansion is precise as the coefficients are available up to $O(\\alpha_s^4)$. We employ $2+1$-flavor lattice ensembles at three lattice spacings in the range 0.044--0.080~fm.

  15. Civil & Military Operations: Evolutionary Prep Steps to Pass Smart Power Current Limitations

    Science.gov (United States)

    2011-06-01

    for learning what you needed to know to evaluate baseball players and baseball games .” (p. 68) – to look for new knowledge on the subject being...of his Ender Series of warfare and future of humanity. “The route of war might succeed for a time – and the operative word in “might,” since...unfair game . W.W. Norton & Company, Inc., New York:NY, 2003. (Mehta, 2011) – Mehta, Seema, Giffords’ surgeon trained on the battlefield. Los Angeles

  16. Dissociation of the store-operated calcium current ICRAC and the Mg-nucleotide-regulated metal ion current MagNuM

    Science.gov (United States)

    Hermosura, Meredith C; Monteilh-Zoller, Mahealani K; Scharenberg, Andrew M; Penner, Reinhold; Fleig, Andrea

    2002-01-01

    Rat basophilic leukaemia cells (RBL-2H3-M1) were used to study the characteristics of the store-operated Ca2+ release-activated Ca2+ current (ICRAC) and the magnesium-nucleotide-regulated metal cation current (MagNuM) (which is conducted by the LTRPC7 channel). Pipette solutions containing 10 mm BAPTA and no added ATP induced both currents in the same cell, but the time to half-maximal activation for MagNuM was about two to three times slower than that of ICRAC. Differential suppression of ICRAC was achieved by buffering free [Ca2+]i to 90 nm and selective inhibition of MagNuM was accomplished by intracellular solutions containing 6 mm Mg.ATP, 1.2 mm free [Mg2+]i or 100 μm GTP-γ-S, allowing investigations on these currents in relative isolation. Removal of extracellular Ca2+ and Mg2+ caused both currents to be carried significantly by monovalent ions. In the absence or presence of free [Mg2+]i, ICRAC carried by monovalent ions inactivated more rapidly and more completely than MagNuM carried by monovalent ions. Since several studies have used divalent-free solutions on either side of the membrane to study selectivity and single-channel behaviour of ICRAC, these experimental conditions would have favoured the contribution of MagNuM to monovalent conductance and call for caution in interpreting results where both ICRAC and MagNuM are activated. PMID:11882677

  17. A power conversion system for PMSG-based WECS operating with fully-controlled current-source converters

    Institute of Scientific and Technical Information of China (English)

    Jian-yu BAO; Wei-bing BAO; Yu-ling LI

    2014-01-01

    We propose a new power conversion system for a permanent magnet synchronous generator (PMSG) based grid-connected wind energy conversion system (WECS) operating with fully-controlled back-to-back current-source converters. On the generator side, two independent current-source rectifiers (CSRs) with space-vector pulse width modulation (SVPWM) are employed to regulate and stabilize DC-link currents. Between DC-link and the electrical grid, a direct-type three-phase five-level current-source inverter (CSI) is inserted as a buffer to regulate real and reactive power fed to the grid and thus adjusts the grid side power-factor. We also present a current-based maximum power point tracking (MPPT) scheme, which helps the generator extract the maximum power through closed-loop regulation of the generator speed. By applying the multilevel modulation and control strategies to the grid-side five-level CSI, a multilevel output current waveform with less distortion is produced, and the bulk requirement of the output capacitor filter to eliminate the harmonic current is reduced. All the proposed concepts are verified by simulation models built in a PSIM environment.

  18. Draft environmental impact statement siting, construction, and operation of New Production Reactor capacity. Volume 4, Appendices D-R

    Energy Technology Data Exchange (ETDEWEB)

    None

    1991-04-01

    This Environmental Impact Statement (EIS) assesses the potential environmental impacts, both on a broad programmatic level and on a project-specific level, concerning a proposed action to provide new tritium production capacity to meet the nation`s nuclear defense requirements well into the 21st century. A capacity equivalent to that of about a 3,000-megawatt (thermal) heavy-water reactor was assumed as a reference basis for analysis in this EIS; this is the approximate capacity of the existing production reactors at DOE`s Savannah River Site near Aiken, South Carolina. The EIS programmatic alternatives address Departmental decisions to be made on whether to build new production facilities, whether to build one or more complexes, what size production capacity to provide, and when to provide this capacity. Project-specific impacts for siting, constructing, and operating new production reactor capacity are assessed for three alternative sites: the Hanford Site near Richland, Washington; the Idaho National Engineering Laboratory near Idaho Falls, Idaho; and the Savannah River Site. For each site, the impacts of three reactor technologies (and supporting facilities) are assessed: a heavy-water reactor, a light-water reactor, and a modular high-temperature gas-cooled reactor. Impacts of the no-action alternative also are assessed. The EIS evaluates impacts related to air quality; noise levels; surface water, groundwater, and wetlands; land use; recreation; visual environment; biotic resources; historical, archaeological, and cultural resources; socioeconomics; transportation; waste management; and human health and safety. The EIS describes in detail the potential radioactive releases from new production reactors and support facilities and assesses the potential doses to workers and the general public. This volume contains 15 appendices.

  19. Tethered Balloon Operations at ARM AMF3 Site at Oliktok Point, AK

    Science.gov (United States)

    Dexheimer, D.; Lucero, D. A.; Helsel, F.; Hardesty, J.; Ivey, M.

    2015-12-01

    Oliktok Point has been the home of the Atmospheric Radiation Measurement Program's (ARM) third ARM Mobile Facility, or AMF3, since October 2013. The AMF3 is operated through Sandia National Laboratories and hosts instrumentation collecting continuous measurements of clouds, aerosols, precipitation, energy, and other meteorological variables. The Arctic region is warming more quickly than any other region due to climate change and Arctic sea ice is declining to record lows. Sparsity of atmospheric data from the Arctic leads to uncertainty in process comprehension, and atmospheric general circulation models (AGCM) are understood to underestimate low cloud presence in the Arctic. Increased vertical resolution of meteorological properties and cloud measurements will improve process understanding and help AGCMs better characterize Arctic clouds. SNL is developing a tethered balloon system capable of regular operation at AMF3 in order to provide increased vertical resolution atmospheric data. The tethered balloon can be operated within clouds at altitudes up to 7,000' AGL within DOE's R-2204 restricted area. Pressure, relative humidity, temperature, wind speed, and wind direction are recorded at multiple altitudes along the tether. These data were validated against stationary met tower data in Albuquerque, NM. The altitudes of the sensors were determined by GPS and calculated using a line counter and clinometer and compared. Wireless wetness sensors and supercooled liquid water content sensors have also been deployed and their data has been compared with other sensors. This presentation will provide an overview of the balloons, sensors, and test flights flown, and will provide a preliminary look at data from sensor validation campaigns and test flights.

  20. Discussion of Planning and Operating of Chongming Qianwei Village's Nongjiale tourism site

    Science.gov (United States)

    Guo, Qingqing; Liu, Min

    According to the sufficient market research the paper put forward the Construction and operation of Chongming Qianwei village Nongjiale tour website completed the Building program of this Business Website. Through needs analysis and feasibility analysis, this paper proposed business model for the target system, transaction mode, revenue model and competitive edge. Opening of the bridge which contact Shanghai and Chongming, coming of the shanghai expo; will bring the growth of passenger traffic of chongming's tourism industry. This article is based on this background, discussing the exploitation and plan of tour website of ChongMing, Enhancing the Popularity and Competitiveness of Chongming's Tourism.

  1. Monticello Mill Tailings Site Operable Unit III Annual Groundwater Report May 2014 Through April 2015, October 2015

    Energy Technology Data Exchange (ETDEWEB)

    Nguyen, Jason [USDOE Office of Legacy Management, Washington, DC (United States); Smith, Fred [Navarro Research and Engineering, Inc., Oak Ridge, TN (United States)

    2015-10-01

    This report provides the annual analysis of water quality restoration progress, cumulative through April 2015, for Operable Unit (OU) III, surface water and groundwater, of the U.S. Department of Energy (DOE) Office of Legacy Management Monticello Mill Tailings Site (MMTS). The MMTS is a Comprehensive Environmental Response, Compensation, and Liability Act National Priorities List site located in and near the city of Monticello, San Juan County, Utah. MMTS comprises the 110-acre site of a former uranium- and vanadium-ore-processing mill (mill site) and 1,700 acres of surrounding private and municipal property. Milling operations generated 2.5 million cubic yards of waste (tailings) from 1942 to 1960. The tailings were impounded at four locations on the mill site. Inorganic constituents in the tailings drained from the impoundments to contaminate local surface water (Montezuma Creek) and groundwater in the underlying alluvial aquifer. Mill tailings dispersed by wind and water also contaminated properties surrounding and downstream of the mill site. Remedial actions to remove and isolate radiologically contaminated soil, sediment, and debris from the former mill site (OU I) and surrounding properties (OU II) were completed in 1999 with the encapsulation of the wastes in an engineered repository located on DOE property 1 mile south of the former mill site. Contamination of groundwater and surface water remains within OU III at levels that exceed water quality protection standards. Uranium is the primary contaminant of concern. LM implemented monitored natural attenuation with institutional controls as the OU III remedy in 2004. Because groundwater restoration proceeded more slowly than expected and did not meet performance criteria established in the OU III Record of Decision (June 2004), LM implemented a contingency action in 2009 by an Explanation of Significant Difference to include a pump-and-treat system using a single extraction well and treatment by zero

  2. US Department of Energy Nevada Operations Office annual site environmental report: 1993. Volume 2: Appendices

    Energy Technology Data Exchange (ETDEWEB)

    Black, S.C.; Glines, W.M.; Townsend, Y.E.

    1994-09-01

    This report is comprised of appendices which support monitoring and surveillance on and around the Nevada Test Site (NTS) during 1993. Appendix A contains onsite Pu-238, gross beta, and gamma-emitting radionuclides in air. Appendix B contains onsite tritium in air. Appendix C contains onsite Pu-238, Sr-90, gross alpha and beta, gamma-emitting radionuclides, Ra-226, Ra-228 and tritium in water. A summary of 1993 results of offsite radiological monitoring is included in Appendix D. Appendix E contains radioactive noble gases in air onsite. Appendix F contains onsite thermoluminescent dosimeter data. Historical trends in onsite thermoluminescent dosimeter data are contained in Appendix G. Appendix H summarizes 1993 compliance at the DOE/NV NTS and non-NTS facilities. Appendix I summarizes the 1993 results of non radiological monitoring.

  3. Voltage- and current-activated metal–insulator transition in VO2-based electrical switches: a lifetime operation analysis

    Directory of Open Access Journals (Sweden)

    Aurelian Crunteanu, Julien Givernaud, Jonathan Leroy, David Mardivirin, Corinne Champeaux, Jean-Christophe Orlianges, Alain Catherinot and Pierre Blondy

    2010-01-01

    Full Text Available Vanadium dioxide is an intensively studied material that undergoes a temperature-induced metal–insulator phase transition accompanied by a large change in electrical resistivity. Electrical switches based on this material show promising properties in terms of speed and broadband operation. The exploration of the failure behavior and reliability of such devices is very important in view of their integration in practical electronic circuits. We performed systematic lifetime investigations of two-terminal switches based on the electrical activation of the metal–insulator transition in VO2 thin films. The devices were integrated in coplanar microwave waveguides (CPWs in series configuration. We detected the evolution of a 10 GHz microwave signal transmitted through the CPW, modulated by the activation of the VO2 switches in both voltage- and current-controlled modes. We demonstrated enhanced lifetime operation of current-controlled VO2-based switching (more than 260 million cycles without failure compared with the voltage-activated mode (breakdown at around 16 million activation cycles. The evolution of the electrical self-oscillations of a VO2-based switch induced in the current-operated mode is a subtle indicator of the material properties modification and can be used to monitor its behavior under various external stresses in sensor applications.

  4. Ionizing radiation exposure in interventional cardiology: current radiation protection practice of invasive cardiology operators in Lithuania.

    Science.gov (United States)

    Valuckiene, Zivile; Jurenas, Martynas; Cibulskaite, Inga

    2016-09-01

    Ionizing radiation management is among the most important safety issues in interventional cardiology. Multiple radiation protection measures allow the minimization of x-ray exposure during interventional procedures. Our purpose was to assess the utilization and effectiveness of radiation protection and optimization techniques among interventional cardiologists in Lithuania. Interventional cardiologists of five cardiac centres were interviewed by anonymized questionnaire, addressing personal use of protective garments, shielding, table/detector positioning, frame rate (FR), resolution, field of view adjustment and collimation. Effective patient doses were compared between operators who work with and without x-ray optimization. Thirty one (68.9%) out of 45 Lithuanian interventional cardiologists participated in the survey. Protective aprons were universally used, but not the thyroid collars; 35.5% (n  =  11) operators use protective eyewear and 12.9% (n  =  4) wear radio-protective caps; 83.9% (n  =  26) use overhanging shields, 58.1% (n  =  18)-portable barriers; 12.9% (n  =  4)-abdominal patient's shielding; 35.5% (n  =  11) work at a high table position; 87.1% (n  =  27) keep an image intensifier/receiver close to the patient; 58.1% (n  =  18) reduce the fluoroscopy FR; 6.5% (n  =  2) reduce the fluoro image detail resolution; 83.9% (n  =  26) use a 'store fluoro' option; 41.9% (N  =  13) reduce magnification for catheter transit; 51.6% (n  =  16) limit image magnification; and 35.5% (n  =  11) use image collimation. Median effective patient doses were significantly lower with x-ray optimization techniques in both diagnostic and therapeutic interventions. Many of the ionizing radiation exposure reduction tools and techniques are underused by a considerable proportion of interventional cardiology operators. The application of basic radiation protection tools and

  5. Water Level and Current Simulation for LOTS Operations - Persian Gulf and Gulf of Oman

    Science.gov (United States)

    1994-07-01

    equations are solved by a finite element approach. However the equations are reformulated mathematically to a form with much improved numerical solution...longer than the tidal cycle, since tidal ebb and flood currents tend to cancel each other. 23Chqpwr 3 Ceibraga wnd Vedication 30 25 (Z 20 M2 "W 15 0 10Q...circulation in the Arabian Gulf," Applied Mathematical Modeling, 14, 410-419. Bogdanov, K. T. (1987). "T’idal wave propagation and tidal level oscillations

  6. Derivation of armature displacement and movement disturbances from current and voltage measurements on solenoid operated valves

    Energy Technology Data Exchange (ETDEWEB)

    Louati, Iskander Alexandre [AREVA NP GmbH (Germany). Service Sector Germany

    2009-07-01

    As part of the electric drive mechanisms of the safety system in nuclear power plants safety related solenoid operated valves (SOVs) are subject to design control, commissioning tests and periodical in-service inspections. AREVA has developed and qualified many methods and tools that have been embedded into as software tools called DAM for diagnosis and evaluation of the valve performance according to the KTA requirements. In the special case of COVs tracing the electric measurements with ADAM helps to detect anomalies at the SOVs and esp. those related to disturbances of the armature moved. The disturbances to be tested are divided into electrical and mechanical disturbances: voltage insufficiency, switch chattering; degradation of spring load, friction collaterally to armature displacement, partial or total obstruction of the armature.

  7. False Operation of Static Random Access Memory Cells under Alternating Current Power Supply Voltage Variation

    Science.gov (United States)

    Sawada, Takuya; Takata, Hidehiro; Nii, Koji; Nagata, Makoto

    2013-04-01

    Static random access memory (SRAM) cores exhibit susceptibility against power supply voltage variation. False operation is investigated among SRAM cells under sinusoidal voltage variation on power lines introduced by direct RF power injection. A standard SRAM core of 16 kbyte in a 90 nm 1.5 V technology is diagnosed with built-in self test and on-die noise monitor techniques. The sensitivity of bit error rate is shown to be high against the frequency of injected voltage variation, while it is not greatly influenced by the difference in frequency and phase against SRAM clocking. It is also observed that the distribution of false bits is substantially random in a cell array.

  8. DOE KSU EV Site Operator Program. [United States Department of Energy (DOE) Kansas State University (KSU) Electric Vehicle (EV)

    Energy Technology Data Exchange (ETDEWEB)

    Hague, J.R.; Steinert, R.A.; Nissen-Pfrang, T.

    1992-01-01

    Kansas State University, with funding from federal, state, public, and private companies, is participating in the DOE Electric Vehicle Site Operator Program. Kansas State is demonstrating, testing, and evaluating electric of hybrid vehicle technology. This will provide organizations the opportunity to examine the latest EHV prototypes under actual operating conditions. KSU proposes to purchase one (1) electric or hybrid van and four(4) electric cars during the first two years of this five-year program. KSU has purchased one G-Van built by Conceptor Industries, Toronto, Canada and has initiated a procurement order to purchase two (2) Soleq 1992 Ford EVcort station wagons. This quarter's report describes ongoing public relations activities and meetings as well as presenting performance data for the electric vehicles. (GHH)

  9. Installation and first operation of the International Fusion Materials Irradiation Facility injector at the Rokkasho site

    Energy Technology Data Exchange (ETDEWEB)

    Gobin, Raphael, E-mail: rjgobin@cea.fr; Bogard, Daniel; Bolzon, Benoit; Bourdelle, Gilles; Chauvin, Nicolas; Chel, Stéphane; Girardot, Patrick; Gomes, Adelino; Guiho, Patrice; Harrault, Francis; Loiseau, Denis; Lussignol, Yves; Misiara, Nicolas; Roger, Arnaud; Senée, Franck; Valette, Matthieu [Commissariat à l’Energie Atomique et aux Energies Alternatives, CEA/Saclay, DSM/IRFU, 91191 Gif/Yvette (France); Cara, Philippe; Duglué, Daniel; Gex, Dominique [Fusion for Energy, BFD Department, Garching (Germany); Okumura, Yoshikazu [IFMIF/EVEDA Project Team, Obuchi-Omotedate, 2-166, Rokkasho, Aomori (Japan); and others

    2016-02-15

    The International Fusion Materials Irradiation Facility (IFMIF) linear IFMIF prototype accelerator injector dedicated to high intensity deuteron beam production has been designed, built, and tested at CEA/Saclay between 2008 and 2012. After the completion of the acceptance tests at Saclay, the injector has been fully sent to Japan. The re-assembly of the injector has been performed between March and May 2014. Then after the check-out phase, the production of the first proton beam occurred in November 2014. Hydrogen and deuteron beam commissioning is now in progress after having proceeded with the final tests on the entire injector equipment including high power diagnostics. This article reports the different phases of the injector installation pointing out the safety and security needs, as well as the first beam production results in Japan and chopper tests. Detailed operation and commissioning results (with H{sup +} and D{sup +} 100 keV beams) are reported in a second article.

  10. Cathode performance during two beam operation of the high current high polarization electron gun for eRHIC

    Energy Technology Data Exchange (ETDEWEB)

    Rahman, O. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ben-Zvi, I. [Brookhaven National Lab. (BNL), Upton, NY (United States); Degen, C. [Brookhaven National Lab. (BNL), Upton, NY (United States); Gassner, D. M. [Brookhaven National Lab. (BNL), Upton, NY (United States); Lambiase, R. [Brookhaven National Lab. (BNL), Upton, NY (United States); Meng, W. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pikin, A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Rao, T. [Brookhaven National Lab. (BNL), Upton, NY (United States); Sheehy, B. [Brookhaven National Lab. (BNL), Upton, NY (United States); Skaritka, J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Wang, E. [Brookhaven National Lab. (BNL), Upton, NY (United States); Pietz, J. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Ackeret, M. [Transfer Engineering and Manufacturing, Inc., Fremont, CA (United States); Yeckel, C. [Stangenes Industries, Palo Alto, CA (United States); Miller, R. [Stangenes Industries, Palo Alto, CA (United States); Dobrin, E. [Stangenes Industries, Palo Alto, CA (United States); Thompson, K. [Stangenes Industries, Palo Alto, CA (United States)

    2015-05-03

    Two electron beams from two activated bulk GaAs photocathodes were successfully combined during the recent beam test of the High Current High Polarization Electron gun for eRHIC. The beam test took place in Stangenes Industries in Palo Alto, CA, where the cathodes were placed in diagonally opposite locations inside the high voltage shroud. No significant cross talking between the cathodes was found for the pertinent vacuum and low average current operation, which is very promising towards combining multiple beams for higher average current. This paper describes the cathode preparation, transport and cathode performance in the gun for the combining test, including the QE and lifetimes of the photocathodes at various steps of the experiment.

  11. Safety analysis--200 Area Savannah River Site: Separations Area operations Building 211-H Outside Facilities. Supplement 11, Revision 1

    Energy Technology Data Exchange (ETDEWEB)

    1993-01-01

    The H-Area Outside Facilities are located in the 200-H Separations Area and are comprised of a number of processes, utilities, and services that support the separations function. Included are enriched uranium loadout, bulk chemical storage, water handling, acid recovery, general purpose evaporation, and segregated solvent facilities. In addition, services for water, electricity, and steam are provided. This Safety Analysis Report (SAR) documents an analysis of the H-Area Outside Facilities and is one of a series of documents for the Separations Area as specified in the SR Implementation Plan for DOE order 5481.1A. The primary purpose of the analysis was to demonstrate that the facility can be operated without undue risk to onsite or offsite populations, to the environment, and to operating personnel. In this report, risks are defined as the expected frequencies of accidents, multiplied by the resulting radiological consequences in person-rem. Following the summary description of facility and operations is the site evaluation including the unique features of the H-Area Outside Facilities. The facility and process design are described in Chapter 3.0 and a description of operations and their impact is given in Chapter 4.0. The accident analysis in Chapter 5.0 is followed by a list of safety related structures and systems (Chapter 6.0) and a description of the Quality Assurance program (Chapter 7.0). The accident analysis in this report focuses on estimating the risk from accidents as a result of operation of the facilities. The operations were evaluated on the basis of three considerations: potential radiological hazards, potential chemical toxicity hazards, and potential conditions uniquely different from normal industrial practice.

  12. Surgical site infections following craniotomy focusing on possible post-operative acquisition of infection: prospective cohort study.

    Science.gov (United States)

    Sneh-Arbib, O; Shiferstein, A; Dagan, N; Fein, S; Telem, L; Muchtar, E; Eliakim-Raz, N; Rubinovitch, B; Rubin, G; Rappaport, Z H; Paul, M

    2013-12-01

    Neurosurgery is characterized by a prolonged risk period for surgical site infection (SSI), mainly related to the presence of cerebrospinal fluid (CSF) drains. We aimed to examine factors associated with post-neurosurgical SSIs, focusing on post-operative factors. A prospective cohort study was conducted in a single center over a period of 18 months in Israel. Included were adult patients undergoing clean or clean-contaminated craniotomy, including craniotomies with external CSF drainage or shunts. SSIs were defined by the Centers for Disease Control and Prevention (CDC) criteria for healthcare-associated infections. All patients were followed up for 90 days and those with foreign body insertion for 1 year. We compared patients with and without SSI. A multivariable regression analysis for SSI was conducted including uncorrelated variables significantly associated with SSI. A total of 502 patients were included, with 138 (27.5%) undergoing emergent or urgent craniotomy. The overall SSI rate was 5.6% (28 patients), of which 3.2% (16 patients) were intracerebral. Non-elective surgery, external CSF drainage/monitoring devices, re-operation, and post-operative respiratory failure were independently associated with subsequent SSI. External CSF devices was the only significant risk factor for intracerebral SSIs (p infection acquisition through external CSF devices. Standard operating procedures for their maintenance are necessary.

  13. Compact teleoperated laparoendoscopic single-site robotic surgical system: Kinematics, control, and operation.

    Science.gov (United States)

    Isaac-Lowry, Oran Jacob; Okamoto, Steele; Pedram, Sahba Aghajani; Woo, Russell; Berkelman, Peter

    2017-03-27

    To date a variety of teleoperated surgical robotic systems have been developed to improve a surgeon's ability to perform demanding single-port procedures. However typical large systems are bulky, expensive, and afford limited angular motion, while smaller designs suffer complications arising from limited motion range, speed, and force generation. This work was to develop and validate a simple, compact, low cost single site teleoperated laparoendoscopic surgical robotic system, with demonstrated capability to carry out basic surgical procedures. This system builds upon previous work done at the University of Hawaii at Manoa and includes instrument and endoscope manipulators as well as compact articulated instruments designed to overcome single incision geometry complications. A robotic endoscope holder was used for the base, with an added support frame for teleoperated manipulators and instruments fabricated mostly from 3D printed parts. Kinematics and control methods were formulated for the novel manipulator configuration. Trajectory following results from an optical motion tracker and sample task performance results are presented. Results indicate that the system has successfully met the goal of basic surgical functionality while minimizing physical size, complexity, and cost. Copyright © 2017 John Wiley & Sons, Ltd.

  14. Adherence to surgical care improvement project measures and post-operative surgical site infections.

    Science.gov (United States)

    Awad, Samir S

    2012-08-01

    Surgical site infection (SSI) is unequivocally morbid and costly. The estimated 300,000 SSIs annually in the United States represent the second most common infection among surgical patients, prolong hospitalization by 7-10 days, and have an estimated annual incremental cost of $1 billion. The mortality rate associated with SSI is 3%, with about three quarters of deaths being attributable directly to the infection. Prevention is possible for the most part, and concerted effort has been made to limit these infections, arguably to little effect. Review of pertinent English-language literature. Numerous risk factors for SSI and tactics for prevention have been described, but efforts to bundle these tactics into an effective, comprehensive prevention program have been disappointing. Numerous studies now demonstrate that the Surgical Care Improvement Program (SCIP), which focused on process improvement rather than outcomes, has been ineffective despite governmental support, financial penalties for non-compliance, and consequent widespread implementation. Required reporting has increased awareness of the problem of SSI, but just as the complexity of SSI risk, pathogenesis, and preventions reflects the complexity of the disease, many other factors must be taken into account, including the skill and knowledge of the surgical team and promulgation of a culture of quality and safety in surgical patient care.

  15. Staff Perspectives on Juvenile Drug Court Operations: A Multi-Site Qualitative Study.

    Science.gov (United States)

    Mericle, Amy A; Belenko, Steven; Festinger, David; Fairfax-Columbo, Jaymes; McCart, Michael R

    2014-09-01

    Substance use is pervasive among youth, particularly among those involved in the juvenile justice system. Juvenile drug courts (JDCs) are a promising approach for delinquent youth with substance abuse issues. However, research regarding JDCs has shown inconsistent effects, and little is known about the specific components associated with positive outcomes. The current study examines data from interviews of JDC judges and team member focus groups in six JDCs from two contiguous southeastern states to identify stakeholders' perceptions about what places youth at risk for involvement in JDC and the factors that may contribute to successful outcomes. In addition, we examine these stakeholders' perceptions of the strengths and challenges facing their JDCs. Our findings highlight the importance of parents and specific strategies implemented by JDCs in influencing the outcomes of youth in JDCs and the importance of interagency collaboration and access to treatment and community resources for the overall success of JDCs.

  16. Key processes shaping the current role and operation of higher education institutions in society

    Directory of Open Access Journals (Sweden)

    Piróg Danuta

    2016-03-01

    Full Text Available The concurrent processes of globalisation, computerisation, and integration shape and constantly modify developmental factors and generate multidirectional social changes. Among social life fields, one of them has been particularly sensitive to the impact of those processes and has remained in clear feedback relationship with them is education, including university-level education. This article aims to present some reflections on the key processes which influence the environment of higher education institutions’ activity and on what their impact specifically is. The factors taken into account include: the transformation of the political and economic system, integration with the European higher education area, the market shift of education, evolving social demands towards higher education institutions and society’s attitude towards work. As knowledge has become an asset largely affecting the quality of life of people and society, universities have changed their focus from searching for and exploring truth, good and beauty in the world towards becoming innovation centres, transferring knowledge as offering their educational services. In this article, those trends have been exemplified in relation to geography degree programmes, and shown through an evolution of the model of the university. Based on a review of the literature, it seems that the processes discussed also concern geography degree programmes, and the future operation of these programmes closely depends on whether they can maintain their care for high quality education coupled with genuine efforts to ensure the smooth transition of graduates into the labour market.

  17. Site Operations Reporting System Based on the Network Separator%基于网络隔离器的现场作业日报告系统

    Institute of Scientific and Technical Information of China (English)

    杨莉; 赵薇; 沈映泉; 王森; 段嘉杰; 杨政; 邓飞

    2015-01-01

    在电力现场作业过程中,工作记录的易用性、规范化和可追溯性对于现场作业精益化管理非常重要。本文研究通用的网络隔离器的工作原理和基础硬件组成,分析总结目前常用的现场作业日报告方法的特征与优缺点,再结合电力企业现阶段的实际情况,如电力内网制度、信息安全规定和电力现场作业标准等,实现基于网络隔离器的实时通信且支持多平台跨网络安全访问的现场作业日报告系统。系统主要包括身份验证、提交现场作业日报告、在ERP中使用现场作业日报告、界面动态显示功能和现场作业日报管理制度等功能模块,解决了电力现场作业无日志记录、跨网络安全、跨平台应用等问题。%In the process of electricity operation,ease of use,standardization and traceability of work records are very important for the lean management of field operations.This paper studied the works and infrastructure hardware components of general network separator,analyzed and summarized the characteristics,advantages and disadvantages of currently used methods of reporting day field operations.Then combined with the actual situation of the power companies at this stage, such as the power grid system,regulations of information safety and standards of operation in the field of electricity,this pa-per achieved a site operation reporting system which supported real-time communication,multi-platform and accessible across the network security based on network separator.The system included authentication,log record of field operations submitted,log record of field operations used in the ERP,the interface dynamically displayed and daily field operations man-agement system and other functional modules to solve the electricity field operations without logging across the network se-curity,cross-platform applications and other issues.

  18. Balancing Energy, Food Security, and Critical Ecosystems: Dam Siting, Design and Operations in the Mekong River Basin

    Science.gov (United States)

    Wild, T. B.; Reed, P. M.; Loucks, D.

    2016-12-01

    The Mekong River basin in Southeast Asia is one of several river basins with exceptionally high biodiversity value where intensive hydropower dam development is anticipated. In the Mekong basin, over 100 dams are planned to be constructed in the next 20-30 years. As planned, these dams will alter the river's natural water, sediment and nutrient flows, and will fragment fish migration pathways. In doing so, they will degrade one of the world's most productive freshwater fish habitats, upon which some 60 million people depend for food and income security. For those dams that have not yet been constructed, there still exist opportunities to modify their siting, design and operation (SDO) to achieve a more balanced set of tradeoffs among hydropower production, sediment/nutrient passage and adult fish/larvae passage. We present a successful case study wherein we explored such alternative SDO opportunities in partnership with the Government of Cambodia for Sambor Dam, planned to be built on the main stem of the Mekong. Sambor would be one of the world's longest dams, spanning 18 km across the river just upstream of (1) Tonle Sap Lake, which supplies 70% of Cambodians' protein, and (2) the Mekong Delta in Vietnam, responsible for 50% of Vietnam's rice production. We will describe key dam siting and design modifications required to mitigate ecological impacts. We will then focus on the most promising alternative dam siting/design concept, exploring the reservoir operations space to demonstrate that a complex set of tradeoffs exist among a diverse set of energy and ecosystem objectives. Results indicate that even for a hydrologically small reservoir, a wide array of potential reservoir operating policies exist that have vastly different food-energy implications. While some policies would significantly mitigate ecological impacts, many policies exist that would pose a severe threat to the sustainability of the fishery. Failure to sample the reservoir operations space at

  19. Atmospheric CO{sub 2} concentrations derived from flask samples collected at USSR-operated sampling sites

    Energy Technology Data Exchange (ETDEWEB)

    Boden, T.A. [comp.] [Oak Ridge National Lab., TN (United States). Carbon Dioxide Information Analysis Center; Brounshtein, A.M.; Faber, E.V.; Shashkov, A.A. [Glavnaya Geofizicheskaya Observatoriya, St. Petersburg (USSR)

    1991-12-01

    This document presents daily atmospheric CO{sub 2} concentrations from four USSR-operated sampling sites (Teriberka Station, Ocean Station Charlie, Bering Island, and Kotelny Island). The period of record varies by station with the earliest measurements dating back to 1983 and recent estimates from early 1991. These CO{sub 2} concentrations are derived from air samples collected in 1.5-L stainless steel electropolished flasks and later analyzed at the Main Geophysical Observatory (St. Petersburg, USSR) using a nondispersive infrared gas analyzer. Measurements not meeting wind direction, wind speed, inter-flask agreement, and climate condition criteria were either discarded or flagged. All measurements have been corrected for drift biases introduced during flask storage. These atmospheric CO{sub 2} concentrations are considered indicative of regional background air conditions and are directly traceable to the World Meteorological Organization`s primary CO{sub 2} standards. These measurements support the rising trend in atmospheric CO{sub 2} concentrations measured at other monitoring sites around the world and may be compared with similar measurements made by various monitoring programs at other northern latitude sites. The document presents the atmospheric CO{sub 2} concentrations in graphical and tabular form, describes the sampling methods, defines limitations and restrictions of the data, and describes the information on the magnetic media.

  20. 农村宅基地抵押试点运行机制研究%Operation Mechanism for Experimental Mortgage of House Sites in the Countryside

    Institute of Scientific and Technical Information of China (English)

    朱凌珂

    2014-01-01

    现行农村宅基地使用权抵押试点分别以财产流转性收益和农村金融市场扩展为抵押主题,采取农民房屋所有权并附属宅基地使用权间接抵押和宅基地使用权直接抵押两种模式,多种类型。试点宅基地使用权抵押融资存在抵押权合法性、抵押物处置效力的法律风险。宅基地使用权抵押应遵循适合我国土地政策和农民利益需求的合理途径,完善抵押登记制度;宅基地使用权转让应适度市场化运作,其受让后的宅基地使用权期限界定为30年为宜。%Currently , there are two themes of experimental mortgage of right to use house sites in the cou-ntryside , one is income of transferring property , and the other expanding rural financial market .There are two experimental models and several types , one is indirect mortgage of ownership of farmers ’ house and affiliated right to use house sites , and the other direct mortgage of right to use house sites .Experimental mortgage finan-cing of right to use house sites may take such legal risks as mortgage legitimacy and the disposal of the mort -gaged property .Mortgage of right to use house sites should follow the reasonable ways that fit land policies in our country and the interest of the farmers .Improve the system of mortgage registration , and abide by market-oriented operation on transferring right to use house sites .It is suggested that the time for transferee ’ s right to use house sites shall be 30 years advisably .

  1. Current applications and future directions for the CDISC Operational Data Model standard: A methodological review.

    Science.gov (United States)

    Hume, Sam; Aerts, Jozef; Sarnikar, Surendra; Huser, Vojtech

    2016-04-01

    In order to further advance research and development on the Clinical Data Interchange Standards Consortium (CDISC) Operational Data Model (ODM) standard, the existing research must be well understood. This paper presents a methodological review of the ODM literature. Specifically, it develops a classification schema to categorize the ODM literature according to how the standard has been applied within the clinical research data lifecycle. This paper suggests areas for future research and development that address ODM's limitations and capitalize on its strengths to support new trends in clinical research informatics. A systematic scan of the following databases was performed: (1) ABI/Inform, (2) ACM Digital, (3) AIS eLibrary, (4) Europe Central PubMed, (5) Google Scholar, (5) IEEE Xplore, (7) PubMed, and (8) ScienceDirect. A Web of Science citation analysis was also performed. The search term used on all databases was "CDISC ODM." The two primary inclusion criteria were: (1) the research must examine the use of ODM as an information system solution component, or (2) the research must critically evaluate ODM against a stated solution usage scenario. Out of 2686 articles identified, 266 were included in a title level review, resulting in 183 articles. An abstract review followed, resulting in 121 remaining articles; and after a full text scan 69 articles met the inclusion criteria. As the demand for interoperability has increased, ODM has shown remarkable flexibility and has been extended to cover a broad range of data and metadata requirements that reach well beyond ODM's original use cases. This flexibility has yielded research literature that covers a diverse array of topic areas. A classification schema reflecting the use of ODM within the clinical research data lifecycle was created to provide a categorized and consolidated view of the ODM literature. The elements of the framework include: (1) EDC (Electronic Data Capture) and EHR (Electronic Health Record

  2. Structural basis of operator sites recognition and effector binding in the TetR family transcription regulator FadR.

    Science.gov (United States)

    Yeo, Hyun Ku; Park, Young Woo; Lee, Jae Young

    2017-04-20

    FadR is a fatty acyl-CoA dependent transcription factor that regulates genes encoding proteins involved in fatty-acid degradation and synthesis pathways. In this study, the crystal structures of Bacillus halodurans FadR, which belong to the TetR family, have been determined in three different forms: ligand-bound, ligand-free and DNA-bound at resolutions of 1.75, 2.05 and 2.80 Å, respectively. Structural and functional data showed that B. halodurans FadR was bound to its operator site without fatty acyl-CoAs. Structural comparisons among the three different forms of B. halodurans FadR revealed that the movement of DNA binding domains toward the operator DNA was blocked upon binding of ligand molecules. These findings suggest that the TetR family FadR negatively regulates the genes involved in fatty acid metabolism by binding cooperatively to the operator DNA as a dimer of dimers. © The Author(s) 2017. Published by Oxford University Press on behalf of Nucleic Acids Research.

  3. Grassland and shrubland birds of Gettysburg National Military Park and Eisenhower National Historic Site: Current status and management recommendations

    Science.gov (United States)

    Peterjohn, Bruce G.

    2007-01-01

    Gettysburg National Military Park (NMP) and Eisenhower National Historic Site (NHS) were surveyed for grassland birds during the 2005 breeding season. These parks currently maintain a total of approximately 1,220 ha (3,015 ac) of grassland habitats within a mosaic of cultivated fields and woodlands. The grasslands are hayfields managed through agricultural leases and fields maintained by the National Park Service (NPS). Most grasslands are composed of introduced cool-season grasses, but Gettysburg NMP maintains a few fields dominated by switchgrass (Panicum virgatum) and is creating additional warm-season grasslands. Hayfields managed through agricultural leases support few grassland birds. The most numerous grassland bird communities are found between Seminary and Cemetery ridges in fields managed by the NPS. The parks discourage hay harvesting before July in all fields in an effort to improve the reproductive success of grassland birds.Shrub-dominated habitats were scarce in both parks. A few areas that were harvested recently for timber supported early successional communities in Gettysburg NMP. Other shrublands were limited to narrow corridors (sparrows (Ammodramus savannarum) were locally distributed in Conservation Reserve Program fields and other grasslands with more open vegetation. Savannah sparrows (Passervulus sandwichensis) were limited to one disturbed area undergoing conversion to warm-season grasses. When compared with other cultural parks in this region, the Gettysburg-Eisenhower complex supports a relatively abundant grassland bird community. This community is restricted to a portion of existing grassland habitats, but the potential exists to support a more diverse and abundant grassland avifauna.The following recommendations provide the most immediate benefits for breeding grassland birds in these parks under the current habitat conditions and management strategies. These recommendations are based on the assumption that the current policy of

  4. Environmental Assessment for the construction and operation of the Three Rivers Solid Waste Authority regional waste management center at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-01

    This Environmental Assessment (EA) has been prepared by the US Department of Energy (DOE) to assess the potential environmental impacts associated with the construction and operation of a landfill and technology center for regionally-generated municipal solid waste at the Savannah River Site (SRS) near Aiken, South Carolina. The facility would serve the municipal solid waste disposal needs for SRS and at least nine of the surrounding counties who currently comprise the Three Rivers Solid Waste Authority (TRSWA). Additional counties could become included in the proposed action at some future date. Current Federal and state requirements do not afford individual counties and municipalities within the region encompassing SRS the ability to efficiently or economically operate modern waste management facilities. In addition, consolidation of regional municipal solid waste at one location would have the benefit of reducing the duplicity of environmental consequences associated with the construction and operation of county-level facilities. The option to seek a combined disposal and technology development facility based on a regionally-cooperative effort was selected as a viable alternative to the existing individual SRS or county disposal activities. This document was prepared in compliance with the National Environmental Policy Act (NEPA) of 1969, as amended, the requirements of the Council on Environmental Quality Regulations for Implementing NEPA (40 CFR Part 1021). NEPA requires the assessment of environmental consequences of Federal actions that may affect the quality of the human environment. Based on the potential for impacts described for impacts described herein, DOE will either publish a Finding of No Significant Impact or prepare an environmental impact statement (EIS).

  5. Analysis of operations and cyber security policies for a system of cooperating Flexible Alternating Current Transmission System (FACTS) devices.

    Energy Technology Data Exchange (ETDEWEB)

    Phillips, Laurence R.; Tejani, Bankim; Margulies, Jonathan; Hills, Jason L.; Richardson, Bryan T.; Baca, Micheal J.; Weiland, Laura

    2005-12-01

    Flexible Alternating Current Transmission Systems (FACTS) devices are installed on electric power transmission lines to stabilize and regulate power flow. Power lines protected by FACTS devices can increase power flow and better respond to contingencies. The University of Missouri Rolla (UMR) is currently working on a multi-year project to examine the potential use of multiple FACTS devices distributed over a large power system region in a cooperative arrangement in which the FACTS devices work together to optimize and stabilize the regional power system. The report describes operational and security challenges that need to be addressed to employ FACTS devices in this way and recommends references, processes, technologies, and policies to address these challenges.

  6. Low-Cost Digital Implementation of Proportional-Resonant Current Controllers for PV Inverter Applications Using Delta Operator

    DEFF Research Database (Denmark)

    Será, Dezsö; Kerekes, Tamas; Lungeanu, Marian

    2005-01-01

    of the P+Resonant controller with selective harmonic compensation on a low-cost fixed-point DSP. The resonant part of the P+R has been implemented as a second order filter based on Delta operator. The current controller, together with harmonic compensation for the 3rd, 5th, and 7th harmonics has been......The performances of the P+Resonant controller in case of current control for a single phase grid connected inverter have been proved to be superior to the PI controller, since it is able to remove the phase error of the control at the fundamental frequency of the grid. It offers also...... the possibility of selective harmonic compensation. However, in case of digital implementation on a low-cost fixedpoint DSP, the limited computational power and the limited numerical representation precision can restrict the utilization of it. The present paper proposes a different way of digital implementation...

  7. From Site Characterization through Safe and Successful CO2 Injection Operation to Post-injection Monitoring and Site Closure - Closing the Full Life Cycle Research at the Ketzin Pilot Site, Germany

    Science.gov (United States)

    Liebscher, Axel

    2017-04-01

    Initiated in 2004, the Ketzin pilot site near Berlin, Germany, was the first European onshore storage project for research and development on geological CO2 storage. After comprehensive site characterization the site infrastructure was build comprising three deep wells and the injection facility including pumps and storage tanks. The operational CO2 injection period started in June 2008 and ended in August 2013 when the site entered the post-injection closure period. During these five years, a total amount of 67 kt of CO2 was safely injected into an Upper Triassic saline sandstone aquifer at a depth of 630 m - 650 m. In fall 2013, the first observation well was partially plugged in the reservoir section with CO2 resistant cement; full abandonment of this well finished in 2015 after roughly 2 years of cement plug monitoring. Abandonment of the remaining wells will be finished by summer 2017 and hand-over of liability to the competent authority is scheduled for end of 2017. The CO2 injected was mainly of food grade quality (purity > 99.9%). In addition, 1.5 kt of CO2 from the oxyfuel pilot capture facility "Schwarze Pumpe" (purity > 99.7%) was injected in 2011. The injection period terminated with a CO2-N2 co-injection experiment of 650 t of a 95% CO2/5% N2 mixture in summer 2013 to study the effects of impurities in the CO2 stream on the injection operation. During regular operation, the CO2 was pre-heated on-site to 40°C prior to injection to ensure a single-phase injection process and avoid any phase transition or transient states within the injection facility or the reservoir. Between March and July 2013, just prior to the CO2-N2 co-injection experiment, the injection temperature was stepwise decreased down to 10°C within a "cold-injection" experiment to study the effects of two-phase injection conditions. During injection operation, the combination of different geochemical and geophysical monitoring methods enabled detection and mapping of the spatial and

  8. LITERATURE SURVEY FOR GROUNDWATER TREATMENT OPTIONS FOR NITRATE IODINE-129 AND URANIUM 200-ZP-1 OPERABLE UNIT HANFORD SITE

    Energy Technology Data Exchange (ETDEWEB)

    BYRNES ME

    2008-06-05

    This literature review presents treatment options for nitrate, iodine-129, and uranium, which are present in groundwater at the 200-ZP-I Groundwater Operable Unit (OU) within the 200 West Area of the Hanford Site. The objective of this review is to determine available methods to treat or sequester these contaminants in place (i.e., in situ) or to pump-and-treat the groundwater aboveground (i.e., ex situ). This review has been conducted with emphasis on commercially available or field-tested technologies, but theoretical studies have, in some cases, been considered when no published field data exist. The initial scope of this literature review included only nitrate and iodine-I 29, but it was later expanded to include uranium. The focus of the literature review was weighted toward researching methods for treatment of nitrate and iodine-129 over uranium because of the relatively greater impact of those compounds identified at the 200-ZP-I OU.

  9. Evaluation and Screening of Remedial Technologies for Uranium at the 300-FF-5 Operable Unit, Hanford Site, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Nimmons, Michael J.

    2007-08-01

    Pacific Northwest National Laboratory (PNNL) is presently conducting a re-evaluation of remedies addressing persistent dissolved uranium concentrations in the upper aquifer under the 300 Area of the Hanford Site in southeastern Washington State. This work is being conducted as a Phase III feasibility study for the 300-FF-5 Operable Unit on behalf of the U.S. Department of Energy. As part of the feasibility study process, a comprehensive inventory of candidate remedial technologies was conducted by PNNL. This report documents the identification and screening of candidate technologies. The screening evaluation was conducted in accordance with guidance and processes specified by U.S. Environmental Protection Agency regulations associated with implementation of the Comprehensive Environmental Response, Compensation, and Liability Act process.

  10. Drain Current Model for Double Gate (DG) p-n-i-n TFET: Accumulation to Inversion Region of Operation

    Science.gov (United States)

    Upasana; Narang, Rakhi; Saxena, Manoj; Gupta, Mridula

    2017-04-01

    In this paper, drain current model has been formulated for Double Gate (DG) p-n-i-n Tunnel FET (TFET) using Lambert-W function. The model includes the impact of mobile charges, gate dielectric thickness (tox) and channel thickness (tsi) on quasi fermi level, gate threshold voltage (VTG), onset voltage (VGonset) and Tunneling Barrier Width (TBW) over the entire operating range i.e. accumulation to inversion state. Important electrostatic and electrical parameters such as the effective potential (φeffective) at the center of the channel, 2-D channel potential, electric field, energy band profile and Tunneling Barrier Width (TBW) dependent drain current have been modeled. Moreover, gate and drain bias controllability in different operating regimes has also been investigated by varying oxide thickness (tox), channel thickness (tsi), intrinsic channel length (Lint) and at different temperatures. Important FOMs required for analog circuit performance such as transconductance (gm), drain conductance (gd), output resistance (Rout), early voltage (VEA) have also been evaluated and verified using ATLAS device simulation software.

  11. Mitochondrial uncoupler FCCP activates proton conductance but does not block store-operated Ca(2+) current in liver cells.

    Science.gov (United States)

    To, Minh-Son; Aromataris, Edoardo C; Castro, Joel; Roberts, Michael L; Barritt, Greg J; Rychkov, Grigori Y

    2010-03-15

    Uncouplers of mitochondrial oxidative phosphorylation, including carbonilcyanide p-triflouromethoxyphenylhydrazone (FCCP) and carbonilcyanide m-cholorophenylhydrazone (CCCP), are widely used in experimental research to investigate the role of mitochondria in cellular function. Unfortunately, it is very difficult to interpret the results obtained in intact cells using FCCP and CCCP, as these agents not only inhibit mitochondrial potential, but may also affect membrane potential and cell volume. Here we show by whole-cell patch clamping that in primary rat hepatocytes and H4IIE liver cells, FCCP induced large proton currents across the plasma membrane, but did not activate any other observable conductance. In intact hepatocytes FCCP inhibits thapsigargin-activated store-operated Ca(2+) entry, but in patch clamping under the conditions of strong Ca(2+) buffering it has no effect on store-operated Ca(2+) current (I(SOC)). These results indicate that there is no direct connection between mitochondria and activation of I(SOC) in liver cells and support the notion of indirect regulation of I(SOC) by mitochondrial Ca(2+) buffering.

  12. Unreviewed Disposal Question Evaluation: Impact of New Information since 2008 PA on Current Low-Level Solid Waste Operations

    Energy Technology Data Exchange (ETDEWEB)

    Flach, G.; Smith, F.; Hamm, L.; Butcher, T.

    2014-10-06

    Solid low-level waste disposal operations are controlled in part by an E-Area Low-Level Waste Facility (ELLWF) Performance Assessment (PA) that was completed by the Savannah River National Laboratory (SRNL) in 2008 (WSRC 2008). Since this baseline analysis, new information pertinent to disposal operations has been identified as a natural outcome of ongoing PA maintenance activities and continuous improvement in model simulation techniques (Flach 2013). An Unreviewed Disposal Question (UDQ) Screening (Attachment 1) has been initiated regarding the continued ability of the ELLWF to meet Department of Energy (DOE) Order 435.1 performance objectives in light of new PA items and data identified since completion of the original UDQ Evaluation (UDQE). The present UDQE assesses the ability of Solid Waste (SW) to meet performance objectives by estimating the influence of new information items on a recent sum-of-fractions (SOF) snapshot for each currently active E-Area low-level waste disposal unit. A final SOF, as impacted by this new information, is projected based on the assumptions that the current disposal limits, Waste Information Tracking System (WITS) administrative controls, and waste stream composition remain unchanged through disposal unit operational closure (Year 2025). Revision 1 of this UDQE addresses the following new PA items and data identified since completion of the original UDQE report in 2013: New Kd values for iodine, radium and uranium; Elimination of cellulose degradation product (CDP) factors; Updated radionuclide data; Changes in transport behavior of mobile radionuclides; Potential delay in interim closure beyond 2025; and Component-in-grout (CIG) plume interaction correction. Consideration of new information relative to the 2008 PA baseline generally indicates greater confidence that PA performance objectives will be met than indicated by current SOF metrics. For SLIT9, the previous prohibition of non-crushable containers in revision 0

  13. Federal environmental standards of potential importance to operations and activities at US Department of Energy sites. Draft

    Energy Technology Data Exchange (ETDEWEB)

    Fowler, K.M.; Bilyard, G.R.; Davidson, S.A.; Jonas, R.J.; Joseph, J.

    1993-06-01

    The US Department of Energy (DOE) is now engaged in a program of environmental restoration nationwide across its 45 sites. It is also bringing its facilities into compliance with environmental regulations, decontaminating and decommissioning unwanted facilities, and constructing new waste management facilities. One of the most difficult questions that DOE must face in successfully remediating its inactive waste sites, decontaminating and decommissioning its inactive facilities, and operating its waste management facilities is: ``What criteria and standards should be met?`` Acceptable standards or procedures for determining standards will assist DOE in its conduct of ongoing waste management and pending cleanup activities by helping to ensure that those activities are conducted in compliance with applicable laws and regulations and are accepted by the regulatory community and the public. This document reports on the second of three baseline activities that are being conducted as prerequisites to either the development of quantitative standards that could be used by DOE, or consistent procedures for developing such standards. The first and third baseline activities are also briefly discussed in conjunction with the second of the three activities.

  14. Reporting surgical site infections following total hip and knee arthroplasty: impact of limiting surveillance to the operative hospital.

    Science.gov (United States)

    Yokoe, Deborah S; Avery, Taliser R; Platt, Richard; Huang, Susan S

    2013-11-01

    Public reporting of surgical site infections (SSIs) by hospitals is largely limited to infections detected during surgical hospitalizations or readmissions to the same facility. SSI rates may be underestimated if patients with SSIs are readmitted to other hospitals. We assessed the impact of readmissions to other facilities on hospitals' SSI rates following primary total hip arthroplasty (THA) or total knee arthroplasty (TKA). This was a retrospective cohort study of all patients who underwent primary THA or TKA at California hospitals between 1 January 2006 and 31 December 2009. SSIs were identified using ICD-9-CM diagnosis codes predictive of SSI assigned at any California hospital within 365 days of surgery using a statewide repository of hospital data that allowed tracking of patients between facilities. We used statewide data to estimate the fraction of each hospital's THA and TKA SSIs identified at the operative hospital versus other hospitals. A total of 91 121 THA and 121 640 TKA procedures were identified. Based on diagnosis codes, SSIs developed following 2214 (2.3%) THAs and 2465 (2.0%) TKAs. Seventeen percent of SSIs would have been missed by operative hospital surveillance alone. The proportion of hospitals' SSIs detected at nonoperative hospitals ranged from 0% to 100%. Including SSIs detected at nonoperative hospitals resulted in better relative ranking for 61% of THA hospitals and 61% of TKA hospitals. Limiting SSI surveillance to the operative hospital caused varying degrees of SSI underestimation and substantially impacted hospitals' relative rankings, suggesting that alternative methods for comprehensive postdischarge surveillance are needed for accurate benchmarking.

  15. Continuous glucose monitoring system in the operating room and intensive care unit: any difference according to measurement sites?

    Science.gov (United States)

    Song, In-Kyung; Lee, Ji-Hyun; Kang, Joo-Eun; Park, Yang-Hyo; Kim, Hee-Soo; Kim, Jin-Tae

    2017-02-01

    Given the benefit of glucose control in the perioperative period, we evaluated the accuracy and performance of the continuous glucose monitoring system (CGMS) depending on different measurement sites in the operating room (OR) and in the intensive care unit (ICU). Patients over 18 years of age scheduled for elective surgery and ICU admission were enrolled prospectively. Two CGMS sensors were inserted into the subcutaneous tissue of the proximal lateral thigh and the lateral abdomen. The rate of successful measurements from thigh and abdomen in the OR and in the ICU were calculated separately. Each CGMS values were compared with the time-matched arterial blood glucose measurements. CGMS values from both measurement sites were also compared. A total of 22 patients undergoing cardiac surgeries were studied. The rate of successful measurements was higher in the ICU (73.2 %) than in the OR (66.0 %) (P = 0.01); however, that from thigh (72.9 %) and from abdomen (58.7 %) showed statistically significant difference only in the OR (P = 0.04). The Pearson correlation coefficient of thigh and abdomen versus arterial values was 0.67 and 0.60, respectively (P < 0.001). In Clarke error grid analysis, 94.6 % (89.3 % in the OR and 96.1 % in the ICU) of values from thigh fell into clinically acceptable zones compared to 93.7 % (89.0 % in the OR and 95.4 % in the ICU) from abdomen. There were no statistically significant differences in the accuracy according to measurement sites. The CGMS showed high measurement failure rate, especially in the OR. In the OR, the rate of successful measurement was higher from thigh than from abdomen. The CGMS showed low accuracy compared to arterial reference values. Nevertheless, there was no difference in the accuracy of the CGMS between two measurement sites. Perioperative performance of the CGMS still needs to be improved considering relatively low successful measurement rates.

  16. Final environmental assessment for off-site transportation of low-level waste from four California sites under the management of the U.S. Department of Energy Oakland Operations Office

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1997-10-01

    The Department of Energy Oakland Operations Office (DOE/OAK) manages sites within California that generate Low Level Waste (LLW) in the course or routine site operations. It is the preference of the DOE to dispose of LLW at federally owned and DOE-operated disposal facilities; however, in some circumstances DOE Headquarters has determined that disposal at commercial facilities is appropriate, as long as the facility meets all regulatory requirements for the acceptance and disposal of LLW, including the passage of a DOE audit to determine the adequacy of the disposal site. The DOE would like to ship LLW from four DOE/OAK sites in California which generate LLW, to NRC-licensed commercial nuclear waste disposal facilities such as Envirocare in Clive, Utah and Chem Nuclear in Barnwell, South Carolina. Transportation impacts for shipment of LLW and MLLW from DOE Oakland sites to other DOE sites was included in the impacts identified in the Department`s Waste Management Programmatic Environmental Impact Statement (WM-PEIS), published in May, 1997, and determined to be low. The low impacts for shipment to commercial sites identified herein is consistent with the WM-PEIS results.

  17. Directed evolution of Tau class glutathione transferases reveals a site that regulates catalytic efficiency and masks co-operativity.

    Science.gov (United States)

    Axarli, Irine; Muleta, Abdi W; Vlachakis, Dimitrios; Kossida, Sophia; Kotzia, Georgia; Maltezos, Anastasios; Dhavala, Prathusha; Papageorgiou, Anastassios C; Labrou, Nikolaos E

    2016-03-01

    A library of Tau class GSTs (glutathione transferases) was constructed by DNA shuffling using the DNA encoding the Glycine max GSTs GmGSTU2-2, GmGSTU4-4 and GmGSTU10-10. The parental GSTs are >88% identical at the sequence level; however, their specificity varies towards different substrates. The DNA library contained chimaeric structures of alternated segments of the parental sequences and point mutations. Chimaeric GST sequences were expressed in Escherichia coli and their enzymatic activities towards CDNB (1-chloro-2,4-dinitrobenzene) and the herbicide fluorodifen (4-nitrophenyl α,α,α-trifluoro-2-nitro-p-tolyl ether) were determined. A chimaeric clone (Sh14) with enhanced CDNB- and fluorodifen-detoxifying activities, and unusual co-operative kinetics towards CDNB and fluorodifen, but not towards GSH, was identified. The structure of Sh14 was determined at 1.75 Å (1 Å=0.1 nm) resolution in complex with S-(p-nitrobenzyl)-glutathione. Analysis of the Sh14 structure showed that a W114C point mutation is responsible for the altered kinetic properties. This was confirmed by the kinetic properties of the Sh14 C114W mutant. It is suggested that the replacement of the bulky tryptophan residue by a smaller amino acid (cysteine) results in conformational changes of the active-site cavity, leading to enhanced catalytic activity of Sh14. Moreover, the structural changes allow the strengthening of the two salt bridges between Glu(66) and Lys(104) at the dimer interface that triggers an allosteric effect and the communication between the hydrophobic sites.

  18. 75 FR 69470 - Tele Atlas North America, Inc., Currently Doing Business as Tom Tom Including Off-Site Workers...

    Science.gov (United States)

    2010-11-12

    ... Employment and Training Administration Tele Atlas North America, Inc., Currently Doing Business as Tom Tom... Doing Business as Tom Tom, Concord, MA; Tele Atlas North America, Inc. Currently Doing Business as Tom Tom, Detroit, MI; Tele Atlas North America, Inc. Currently Doing Business as Tom Tom, Redwood, CA...

  19. Next Generation Nuclear Plant Project Evaluation of Siting a HTGR Co-generation Plant on an Operating Commercial Nuclear Power Plant Site

    Energy Technology Data Exchange (ETDEWEB)

    L.E. Demick

    2011-10-01

    This paper summarizes an evaluation by the Idaho National Laboratory (INL) Next Generation Nuclear Plant (NGNP) Project of siting a High Temperature Gas-cooled Reactor (HTGR) plant on an existing nuclear plant site that is located in an area of significant industrial activity. This is a co-generation application in which the HTGR Plant will be supplying steam and electricity to one or more of the nearby industrial plants.

  20. Highly enantioselective cross-aldol reactions of acetaldehyde mediated by a dual catalytic system operating under site isolation.

    Science.gov (United States)

    Fan, Xinyuan; Rodríguez-Escrich, Carles; Wang, Shoulei; Sayalero, Sonia; Pericàs, Miquel A

    2014-10-06

    Polystyrene-supported (PS) diarylprolinol catalysts 1 a (Ar = phenyl) and 1 b (Ar = 3,5-bis(trifluoromethyl)phenyl) have been developed. Operating under site-isolation conditions, PS-1 a/1 b worked compatibly with PS-bound sulfonic acid catalyst 2 to promote deoligomerization of paraldehyde and subsequent cross-aldol reactions of the resulting acetaldehyde in one pot, affording aldol products in high yields with excellent enantioselectivities. The effect of water on the performance of the catalytic system has been studied and its optimal amount (0.5 equiv) has been determined. The dual catalytic system (1/2) allows repeated recycling and reuse (10 cycles). The potential of this methodology is demonstrated by a two-step synthesis of a phenoperidine analogue (68% overall yield; 98% ee) and by the preparation of highly enantioenriched 1,3-diols 4 and 3-methylamino-1-arylpropanols 5, key intermediates in the synthesis of a variety of druglike structures. © 2014 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  1. Post-Closure Monitoring Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Effluent Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    K. B. Campbell

    2002-09-01

    The Area 12 Fleet Operations Steam Cleaning Effluent site is located in the southeastern portion of the Area 12 Camp at the Nevada Test Site. This site is identified in the Federal Facility Agreement and Consent Order (1996) as Corrective Action Site (CAS) 12-19-01 and is the only CAS assigned to Corrective Action Unit (CAU) 339. Post-closure sampling and inspection of the site were completed on March 27, 2002. Post-closure monitoring activities were scheduled biennially (every two years) in the Post-Closure Monitoring Plan provided in the Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Effluent, Nevada Test Site (U.S. Department of Energy, Nevada Operations Office [DOEN], 1997). A baseline for the site was established by sampling in 1997. Based on the recommendations from the 1999 post-closure monitoring report (DOE/NV, 1999), samples were collected in 2000, earlier than originally proposed, because the 1999 sample results did not provide the expected decrease in total petroleum hydrocarbon (TPH) concentrations at the site. Sampling results from 2000 (DOE/NV, 2000) and 2001 (DOE/NV, 2001) revealed favorable conditions for natural degradation at the CAU 339 site, but because of differing sample methods and heterogeneity of the soil, data results from 2000 and later were not directly correlated with previous results. Post-closure monitoring activities for 2002 consisted of the following: (1) Soil sample collection from three undisturbed plots (Plots A, B, and C, Figure 2). (2) Sample analysis for TPH as oil and bio-characterization parameters (Comparative Enumeration Assay [CEA] and Standard Nutrient Panel [SNP]). (3) Site inspection to evaluate the condition of the fencing and signs. (4) Preparation and submittal of the Post-Closure Monitoring Report.

  2. Fission product iodine during early Hanford-Site operations: Its production and behavior during fuel processing, off-gas treatment and release to the atmosphere

    Energy Technology Data Exchange (ETDEWEB)

    Burger, L.L.

    1991-05-01

    The Hanford Environmental Dose Reconstruction (HEDR) Project was established to estimate the radiological dose impact that Hanford Site operations may have made on the local and regional population. This impact is estimated by examining operations involving radioactive materials that were conducted at the Hanford Site from the startup of the first reactor in 1944 to the present. HEDR Project work is divided among several technical tasks. One of these tasks, Source Terms, is designed to develop quantitative estimates of all significant emissions of radionuclides by Hanford Site operations since 1944. Radiation doses can be estimated from these emissions by accounting for specific radionuclide transport conditions and population demography. This document provides technical information to assist in the evaluation of iodine releases. 115 refs., 5 figs., 3 tabs.

  3. The Bipolar Field-Effect Transistor:Ⅶ. The Unipolar Current Mode for Analog-RF Operation(Two-MOS-Gates on Pure-Base

    Institute of Scientific and Technical Information of China (English)

    Jie Binbin; Sah Chih-Tang

    2009-01-01

    This paper reports the DC steady-state current-voltage and conductance-voltage characteristics of a Bipolar Field-Effect Transistor (BiFET) under the unipolar (electron) current mode of operation, with bipolar (elec-tron and hole) charge distributions considered. The model BiFET example presented has two MOS-gates on the two surfaces of a thin pure silicon base layer with electron and hole contacts on both edges of the thin base. The hole contacts on both edges of the thin pure base layer are grounded to give zero hole current. This 1-transistor analog-RF Basic Building Block nMOS amplifier circuit, operated in the unipolar current mode, complements the 1-transistor digital Basic Build Block CMOS voltage inverter circuit, operated in the bipolar-current mode just presented by us.

  4. Post-Closure Monitoring Report for Corrective Action Unit 339: Area 12 Fleet Operations Steam Cleaning Discharge Area Nevada Test Site, Nevada

    Energy Technology Data Exchange (ETDEWEB)

    A. T. Urbon

    2001-08-01

    The Area 12 Fleet Operations Steam Cleaning site is located in the southeast portion of the Area 12 Camp at the Nevada Test Site (Figure 1). This site is identified in the Federal Facility Agreement and Consent Order (FFACO, 1996) as Corrective Action Site (CAS) 12-19-01 and is the only CAS assigned to Corrective Action Unit (CAU) 339. Post-closure sampling and inspection of the site were completed on March 23, 2001. Because of questionable representativeness and precision of the results, the site was resampled on June 12, 2001. Post-closure monitoring activities were scheduled biennially (every two years) in the Post-Closure Monitoring Plan provided in the December 1997 Closure Report for CAU 339: Area 12 Fleet Operations Steam Cleaning Discharge Area, Nevada Test Site (U.S. Department of Energy, Nevada Operations Office [DOE/NV], 1997). If after six years the rate of degradation appears to be so slow that the greatest concentration of total petroleum hydrocarbons (TPH) present at the site would not decay within 30 years of the site closure, the site will be reevaluated with consideration to enriching the impacted soil at the site to enhance the degradation process. A baseline for the site was established by sampling in 1997. Based on the recommendations from the 1999 post-closure monitoring report, samples were collected in 2000, earlier than originally proposed, because the 1999 sample results did not provide the expected decrease in TPH concentrations at the site. Sampling results from 2000 revealed favorable conditions for natural degradation at the CAU 339 site, but because of differing sample methods and heterogeneity of the soil, the data results from 2000 were not directly correlated with previous results. Post-closure monitoring activities for 2001 consisted of the following: Soil sample collection from three undisturbed plots (Plots A, B, and C, Figure 2); Sample analysis for TPH as oil and bio-characterization parameters (Comparative Enumeration Assay

  5. The effect of applied control strategy on the current-voltage correlation of a solid oxide fuel cell stack during dynamic operation

    Directory of Open Access Journals (Sweden)

    Szmyd Janusz S.

    2014-09-01

    Full Text Available This paper discusses the transient characteristics of the planar type SOFC cell stack, of which the standard output is 300 W. The transient response of the voltage to the manipulation of an electric current was investigated. The effects of the response and of the operating condition determined by the operating temperature of the stack were studied by mapping a current-voltage (I-V correlation. The current-based fuel control (CBFC was adopted for keeping the fuel utilization factor at constant while the value of the electric current was ramped at the constant rate. The present experimental study shows that the transient characteristics of the cell voltage are determined by primarily the operating temperature caused by the manipulation of the current. Particularly, the slope of the I-V curve and the overshoot found on the voltage was remarkably influenced by the operating temperature. The different values of the fuel utilization factor influence the height of the settled voltages. The CBFC has significance in determining the slope of the I-V characteristic, but the different values ofthe fuel utilization factor does not affect the slope as the operating temperature does. The CBFC essentially does not alter the amplitude of the overshoot on the voltage response, since this is dominated by the operating temperature and its change is caused by manipulating the current.

  6. The Legal Implications of Student Use of Social Networking Sites in the UK and US: Current Concerns and Lessons for the Future

    Science.gov (United States)

    Davies, Mark R.; Lee, Barbara A.

    2008-01-01

    This paper provides a comparative snapshot of the current state of the law in the US and UK with respect to potential liability of university and college students for use (and misuse) of social networking sites. It reviews the limited case law on this topic, highlights the differences in the two nations' laws of defamation and the various possible…

  7. [Current status of operations in community general support centers and the correlation of personal traits, work environment and occupational stress].

    Science.gov (United States)

    Yamaguchi, Yoshie

    2010-01-01

    The purpose of this study was to identify the current status of operations at community general support centers which provide coordination for elderly care and the correlation of personal traits, work environment and the occupational stress of the staff. Subjects of the study were 251 staff members of community general support centers. The current status of operations at the community general support centers and the personal traits, work environment, effort-remuneration imbalance model (ERI) and general health questionnaire (GHQ) were surveyed. The initial analysis involved a comparison by a chi-square test on: The effort-remuneration ratio (E/R ratio) of personal traits and work environment, risk of over-commitment (OC), and GHQ score. To explore the correlation between the E/R ratio of the three GHQ groups (low, middle and high score groups) and the OC value, one-way analysis of variance was performed. Out of the four basic functions of the community general support centers, 22.0% of the respondents noted that "establishment of a regional, comprehensive/multi-tiered service network" was functioning, and 50.4% of respondents noted that "comprehensive and continuous care management" was functioning. The average effort score was 15.5 +/- 5.3, approximately double the average value of preceding studies. Significant differences found in GHQ scores were related to working hours (pworking hours of 50 h or more" (OR: 10.38, 95% CI: 2.52-42.70), "Unstable employment" (OR: 2.75, 95% CI: 1.22-6.21) and "Anxiety related to task content" (OR: 17.04, 95% CI: 3.57-81.24). Items observed to have significant correlation with OC value risk factors were: "Weekly working hours of 50 h or more" (OR: 8.04, 95% CI: 1.99-32.41) and "Anxiety related to task content" (OR: 4.60, 95% CI: 2.04-10.37). We conclude that the basic functions of the community general support centers are not presently very functional. The stress levels of the community general support center staff are high and

  8. Proposal for the award of an industrial service contract for stores operations and relatedlogistics, in-house mail distribution and transport services on the CERN site

    CERN Document Server

    2006-01-01

    This document concerns the award of an industrial support contract for stores operations and related logistics, in-house mail distribution and transport services on the CERN site. The Finance Committee is invited to agree to the negotiation of a contract with the consortium ISS (CH) - ISS (ES), for stores operations and related logistics, in-house mail distribution and transport services on the CERN site for a period of three years for a total amount not exceeding 10 312 028 Swiss francs not subject to revision. The contract will include options for two one-year extensions beyond the initial three-year period.

  9. SWEIS Yearbook-2012 Comparison of 2012 Data to Projections of the 2008 Site-Wide Environmental Impact Statement for Continued Operation of Los Alamos National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Mahowald, Hallie B. [Los Alamos National Lab. (LANL), Los Alamos, NM (United States); Wright, Marjorie Alys [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2014-01-16

    Los Alamos National Laboratory (LANL or the Laboratory) operations data for Calendar Year (CY) 2012 mostly fell within the 2008 Site-Wide Environmental Impact Statement (SWEIS) projections. Operation levels for one LANL facility exceeded the 2008 SWEIS capability projections—Radiochemistry Facility; however, none of the capability increases caused exceedances in radioactive air emissions, waste generation, or National Pollutant Discharge Elimination System (NPDES) discharge. Several facilities exceeded the2008 SWEIS levels for waste generation quantities; however, all were one-time, non-routine events that do not reflect the day-to-day operations of the Laboratory. In addition, total site-wide waste generation quantities were below SWEIS projections for all waste types, reflecting the overall levels of operations at both the Key and Non-Key Facilities. Although gas and electricity consumption have remained within the 2008 SWEIS limits for utilities, water consumption exceeded the 2008 SWEIS projections by 27 million gallons in CY 2012.

  10. Air-sea exchange of CO2 at a Northern California coastal site along the California Current upwelling system

    Directory of Open Access Journals (Sweden)

    W. C. Oechel

    2012-12-01

    Full Text Available Uncertainty in the air-sea CO2 exchange (CO2 flux in coastal upwelling zones is attributed to high temporal variability, which is caused by changes in ocean currents. Upwelling transports heterotrophic, CO2 enriched water to the surface and releases CO2 to the atmosphere, whereas the presence of nutrient-rich water at the surface supports high primary production and atmospheric CO2 uptake. To quantify the effects of upwelling on CO2 fluxes, we measured CO2 flux at a coastal upwelling site off of Bodega Bay, California, during the summer of 2007 and the fall of 2008 using the eddy covariance technique and the bulk method with pCO2 measurements from November 2010 to July 2011. Variations in sea surface temperatures (SST and alongshore wind speeds suggest that the measurement period in 2007 coincided with a typical early-summer upwelling period and the measurement period in 2008 was during a typical fall relaxation period. A strong source of CO2 (~1.5 ± 7 SD (standard deviation g C m−2 day−1 from the ocean to the atmosphere during the upwelling period was concurrent with high salinity, low SST, and low chlorophyll density. In contrast, a weak source of CO2 flux (~0.2 ± 3 SD g C m−2 day−1 was observed with low salinity, high SST and high chlorophyll density during the relaxation period. Similarly, the sink and source balance of CO2flux was highly related to salinity and SST during the pCO2 measurement periods; high salinity and low SST corresponded to high pCO2, and vice versa. We estimated that the coastal area off Bodega Bay was likely a source of CO2 to the atmosphere based on the following conclusions: (1 the overall CO2 flux estimated from both eddy covariance and pCO2 measurements showed a source of CO2; (2 although the relaxation period during the 2008 measurements were favorable to CO2 uptake, CO2 flux during this period was still a slight source, (3 salinity and SST were found to be good predictors of the CO2 flux for both eddy

  11. HANFORD SITE AIR OPERATING PERMIT SEMIANNUAL REPORT FOR THE PERIOD 07/01/2004 THRU 12/31/2004

    Energy Technology Data Exchange (ETDEWEB)

    GREEN, W.E.

    2005-01-19

    The Hanford Site Air Operating Permit (AOP), Number 00-05-006, became effective on July 2, 2001. One condition contained in the AOP, ''Standard Terms and Conditions'', Section 4.3.3, is the requirement to submit semiannual reports by March 15th and September 15th each year, which are certified for truth, accuracy, and completeness by a Responsible Official. This semiannual report contains information from July 1, 2004 through December 31, 2004. Copies of semiannual reports are transmitted to the Washington State Department of Ecology (Ecology). the Washington State Department of Health (WDOH), the Benton Clean Air Authority (BCAA), and the US Environmental Protection Agency (EPA), Region 10. For the applicable reporting period, AOP, ''Standard Terms and Conditions'', Section 4.3.3, as amended in August 2002 and December 2002, identifies the following. (1) Each semiannual report will provide a reference to deviation reports submitted to the regulatory agencies as required by Section 4.5. ''Permit Deviation Reporting''. (2) Each semiannual report will consist of reports of any required monitoring not submitted previously to the agencies or a reference to reports of required monitoring submitted during the reporting period. (3) Each semiannual report will contain a summary of any substantiated air emission complaint investigation(s) required in Table 1.2 of AOP, Attachment 1, and issued during the reporting period. (4) For all minor radioactive emission points (potential to emit <0.1 mrem to the maximally exposed individual) listed in AOP, Attachment 2. Tables 1.2. 1.3, and 2.1, each semiannual report will confirm that any required monitoring was conducted to verify low emissions during the reporting period. Data derived from that monitoring will be reported in the Annual National Emission Standards for Hazardous Air Pollutants (NESHAP) Report (AOP, ''Standard Terms and Conditions

  12. Use of reconnaissance level information for environmental assessment. [Information available from existing sources that satisfies information needs of siting and operational aspects of NPP

    Energy Technology Data Exchange (ETDEWEB)

    Foster, R.F.; Rickard, W.H.; Strand, J.A.; Warner, M.L.

    1979-11-01

    Reconnaissance level information (RLI) sufficient for comparing the environmental and socio-economic features of candidate sites for nuclear power stations and for guiding plant design, baseline surveys, and operational practices is usually available from published reports, public records, and knowledgeable individuals. Environmental concerns of special importance for site evaluation include: aquatic ecology, terrestrial ecology, land and water use, socio-economics, and institutional constraints. A scheme is suggested for using RLI to assign classifications to candidate sites based on the potential level of concern associated with the different environmental features.

  13. Operational waste volume projection

    Energy Technology Data Exchange (ETDEWEB)

    Koreski, G.M.

    1996-09-20

    Waste receipts to the double-shell tank system are analyzed and wastes through the year 2015 are projected based on generation trends of the past 12 months. A computer simulation of site operations is performed, which results in projections of tank fill schedules, tank transfers, evaporator operations, tank retrieval, and aging waste tank usage. This projection incorporates current budget planning and the clean-up schedule of the Tri-Party Agreement. Assumptions were current as of June 1996.

  14. History of the 185-/189-D thermal hydraulics laboratory and its effects on reactor operations at the Hanford Site

    Energy Technology Data Exchange (ETDEWEB)

    Gerber, M.S.

    1994-09-01

    The 185-D deaeration building and the 189-D refrigeration building were constructed at Hanford during 1943 and 1944. Both buildings were constructed as part of the influent water cooling system for D reactor. The CMS studies eliminated the need for 185-D function. Early gains in knowledge ended the original function of the 189-D building mission. In 1951, 185-D and 189-D were converted to a thermal-hydraulic laboratory. The experiments held in the thermal-hydraulic lab lead to historic changes in Hanford reactor operations. In late 1951, the exponential physics experiments were moved to the 189-D building. In 1958, new production reactor experiments were begun in 185/189-D. In 1959, Plutonium Recycle Test Reactor experiments were added to the 185/189-D facility. By 1960, the 185/189-D thermal hydraulics laboratory was one of the few full service facilities of its type in the nation. During the years 1961--1963 tests continued in the facility in support of existing reactors, new production reactors, and the Plutonium Recycle Test Reactor. In 1969, Fast Flux Test Facility developmental testings began in the facility. Simulations in 185/189-D building aided in the N Reactor repairs in the 1980`s. In 1994 the facility was nominated to the National Register of Historic Places, because of its pioneering role over many years in thermal hydraulics, flow studies, heat transfer, and other reactor coolant support work. During 1994 and 1995 it was demolished in the largest decontamination and decommissioning project thus far in Hanford Site history.

  15. MX Siting Investigation. Preliminary Biological and Cultural Resources Inventory and Environmental Evaluation of the Proposed Operational Base Sites in Coyote Spring Valley and the Milford-Beryl Area.

    Science.gov (United States)

    1981-03-20

    Stanleya pinriata (desert prince- plume) Stanleya sp. X CACTACEAE Echinocereus engelmannii (Engel- X X X X X X mann echinocereus) Ferocactus acanthodes...TABLE 3-3 (Cont.) Site Number Species 1 2 3 4 5 6 7 8 9 CACTACEAE (Cont.) Ferocactus sp X X X X *Neolloydia sp. X *-Opuntia basilaris (beavertail X X

  16. Current regulators for I/SUP 2/L circuits to be operated from low-voltage power supplies

    DEFF Research Database (Denmark)

    Bruun, Erik; Hansen, Ole

    1980-01-01

    A new bandgap current reference is described which can be used to control the injector current of I/SUP 2/L circuits for supply voltages down to about 1 V. For small currents the total injector current is obtained as a mirror of the reference current. For large injector currents the current control...... is performed by a series regulator which compares the injector current of one I/SUP 2/L gate to the reference current. The described reference current can be adjusted to give a variation with temperature of about 60 ppm/°C over the temperature range -10 to +70°C. However, in some applications a nonzero......, but well controlled temperature coefficient is desired. It is shown how a temperature stable ring oscillator with I/SUP 2/L gates can be constructed by tailoring the temperature dependence of the supply current appropriately....

  17. New method for estimating current and future transport aircraft operating economics. Contractor report, Jan 1976--Oct 1977

    Energy Technology Data Exchange (ETDEWEB)

    1978-01-01

    A methodology was developed by which the operating cost associated with variations in aircraft design and technology characteristics can be assessed. This methodology addresses aircraft related operating cost elements and is based on an in-depth examination of airline operating experiences and relevant operating data. The assessment method produces a base line estimate of the operating cost elements relating to such design specification features as seat capacity, avionic equipment, design range, and design definition features such as maximum takeoff gross weight, and number of engines. Means for determining the deviations from this base line of the design or technological difference at the specific ATA System level are provided. The methodology was applied to assess the operating cost of one potential future advanced technology transport aircraft. An analysis was included to show the relative sensitivity of the operating cost to design parameters. Areas of potential future research on operating cost related technologies are identified.

  18. Electric and hybrid vehicle program; Site Operator Program. Quarterly progress report, January--March 1992 (Second quarter of fiscal year 1992)

    Energy Technology Data Exchange (ETDEWEB)

    Warren, J.F.

    1992-05-01

    Activities during the second quarter included the second meeting of the Site Operators in Phoenix, AZ in late April. The meeting was held in conjunction with the Solar and Electric 500 Race activities. Delivery of vehicles ordered previously has begun, although two of the operators are experiencing some delays in receiving their vehicles. Public demonstration activities continue, with an apparent increasing level of awareness and interest being displayed by the public. Initial problems with the Site Operator Database have been corrected and revised copies of the program have been supplied to the Program participants. Operating and Maintenance data is being supplied and submitted to INEL on a monthly basis. Interest in the Site Operator Program is being reflected in requests for information from several organizations from across the country, representing a wide diversity of interests. These organizations have been referred to existing Site Operators with the explanation that the program will not be adding new participants, but that most of the existing organizations are willing to work with other groups. The exception to this was the addition of Potomac Electric Power Company (PEPCO) to the program. PEPCO has been awarded a subcontract to operate and maintain the DOE owned G-Van and Escort located in Washington, DC. They will provide data on these vehicles, as well as a Solectria Force which PEPCO has purchased. The Task Force intends to be actively involved in the infrastructure development in a wide range of areas. These include, among others, personnel development, safety, charging, and servicing. Work continues in these areas. York Technical College (YORK) has completed the draft outline for the EV Technician course. This is being circulated to organizations around the country for comments. Kansas State University (KSU) is working with a private sector company to develop a energy dispensing meter for opportunity charging in public areas.

  19. Current Practices in Global/International Advanced Pharmacy Practice Experiences: Home/Host Country or Site/Institution Considerations

    National Research Council Canada - National Science Library

    Naser Z Alsharif; Adnan Dakkuri; Jeanine P Abrons; Dennis Williams; David N Ombengi; HaiAn Zheng; Sara Al-Dahir; Toyin Tofade; Suzanna Gim; Mary Beth O'Connell; Anna Ratka; Emily Dornblaser

    2016-01-01

      International outreach by schools and colleges of pharmacy is increasing. In this paper, we provide current practice guidelines to establish and maintain successful global/international advanced pharmacy practice experiences (G/I APPEs...

  20. Development and Use of a Web Site with Multimedia Contents as a Complement to Traditional Unit Operations Courses

    Science.gov (United States)

    Tapia, Cristian; Muller, Mauricio; Sapag-Hagar, Jaime; Valenzuela, Fernando; Basualto, Carlos; Abugoch, Lilian

    2005-01-01

    The Unit Operations Laboratory offers 2 courses in unit operations. One is a 2-semester course for chemistry and food engineering students that is more demanding because it considers more unit operations and places more emphasis on solving exercises. The other is a 1-semester course for chemistry and pharmacy students that considers fewer unit…

  1. 77 FR 67399 - Trim Systems Operating Corp., a Subsidiary of Commercial Vehicle Group, Inc., Including On-Site...

    Science.gov (United States)

    2012-11-09

    ... Employment and Training Administration Trim Systems Operating Corp., a Subsidiary of Commercial Vehicle Group... of Trim Systems Operating Corp., a subsidiary of Commercial Vehicle Group, Inc., Statesville, North... applicable to TA-W-81,393 is hereby issued as follows: All workers of Trim Systems Operating Corp.,...

  2. Operational Definition of Active and Healthy Aging (AHA) : The European Innovation Partnership (EIP) on AHA Reference Site Questionnaire: Montpellier October 20-21, 2014, Lisbon July 2, 2015

    NARCIS (Netherlands)

    Bousquet, Jean; Malva, Joao; Nogues, Michel; Mañas, Leocadio Rodriguez; Vellas, Bruno; Farrell, John; Smit, HA

    2015-01-01

    A core operational definition of active and healthy aging (AHA) is needed to conduct comparisons. A conceptual AHA framework proposed by the European Innovation Partnership on Active and Healthy Ageing Reference Site Network includes several items such as functioning (individual capability and

  3. Sampling and analysis plan for the site characterization of the waste area Grouping 1 groundwater operable unit at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1994-11-01

    Waste Area Grouping (WAG) 1 at Oak Ridge National Laboratory (ORNL) includes all of the former ORNL radioisotope research, production, and maintenance facilities; former waste management areas; and some former administrative buildings. Site operations have contaminated groundwater, principally with radiological contamination. An extensive network of underground pipelines and utilities have contributed to the dispersal of contaminants to a known extent. In addition, karst geology, numerous spills, and pipeline leaks, together with the long and varied history of activities at specific facilities at ORNL, complicate contaminant migration-pathway analysis and source identification. To evaluate the extent of contamination, site characterization activity will include semiannual and annual groundwater sampling, as well as monthly water level measurements (both manual and continuous) at WAG 1. This sampling and analysis plan provides the methods and procedures to conduct site characterization for the Phase 1 Remedial Investigation of the WAG 1 Groundwater Operable Unit.

  4. Survey of historical and current site selection techniques for the placement of small wind energy conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Katzenberg, Rick; Pierson, Chris; Fry, Sheldon; Drees, Herman; Drees, Carolyn; Wolff, Ben; Blake, Steve; Saylor, John; Park, Jack; Park, Helen

    1977-12-01

    Individuals and groups who purchase and install wind energy conversion systems (WECS) for either generation of electricity or pumping water have to go through a process by which a specific location is selected for each WECS. The purpose of this study was to identify and document methods and practices used in siting of WECS. The study covers the period from the early 1900s to the present day. 174 references.

  5. Survey of historical and current site selection techniques for the placement of small wind energy conversion systems

    Energy Technology Data Exchange (ETDEWEB)

    Katzenberg, Rick; Pierson, Chris; Fry, Sheldon; Drees, Herman; Drees, Carolyn; Wolff, Ben; Blake, Steve; Saylor, John; Park, Jack; Park, Helen

    1977-12-01

    Individuals and groups who purchase and install wind energy conversion systems (WECS) for either generation of electricity or pumping water have to go through a process by which a specific location is selected for each WECS. The purpose of this study was to identify and document methods and practices used in siting of WECS. The study covers the period from the early 1900s to the present day. 174 references.

  6. (Un)supported Current Tourism Development in UNESCO Protected Site: The Case of Old City of Dubrovnik

    OpenAIRE

    Ivana Pavlić; Ana Portolan; Barbara Puh

    2017-01-01

    The main purpose of this paper is to explore and determine perceptions of residents living in the United Nations Educational, Scientific and Cultural Organization (UNESCO) protected site Old City of Dubrovnik (OCD) towards tourism development. Uncontrolled tourism expansion has impact on local residents’ life and on their (un)support for specific form of tourism development. Comprehension of residents’ perceptions is crucial for realization of adequate tourism development and for mutual satis...

  7. Environmental Assessment for Leasing Land for the Siting, Construction and Operation of a Commercial AM Radio Antenna at Los Alamos National Laboratory, Los Alamos, NM

    Energy Technology Data Exchange (ETDEWEB)

    N/A

    2000-02-16

    The United States (U.S.) Department of Energy (DOE) proposes to lease approximately 3 acres of land at the Los Alamos National Laboratory (LANL) on the southeast tip of Technical Area (TA) 54 for the siting, construction and operation of an AM radio broadcasting antenna. This Environmental Assessment (EA) has been developed in order to assess the environmental effects of the Proposed Action and No Action alternative. The Proposed Action includes the lease of land for the siting, construction and operation of an AM radio broadcasting antenna in TA-54, just north of Pajarito Road and State Highway 4. The No Action Alternative was also considered. Under the No Action Alternative, DOE would not lease land on LANL property for the siting and operation of an AM radio broadcasting antenna; the DOE would not have a local station for emergency response use; and the land would continue to be covered in native vegetation and serve as a health and safety buffer zone for TA-54 waste management activities. Other potential sites on LANL property were evaluated but dismissed for reasons such as interference with sensitive laboratory experiments. Potential visual, health, and environmental effects are anticipated to be minimal for the Proposed Action. The radio broadcasting antenna would be visible against the skyline from some public areas, but would be consistent with other man-made objects in the vicinity that partially obstruct viewsheds (e.g. meteorological tower, power lines). Therefore, the net result would be a modest change of the existing view. Electromagnetic field (EMF) emissions from the antenna would be orders or magnitude less than permissible limits. The proposed antenna construction would not affect known cultural sites, but is located in close proximity to two archaeological sites. Construction would be monitored to ensure that the associated road and utility corridor would avoid cultural sites.

  8. Hanford Site Air Operating Permit Semiannual Report for the period July 21 2001 Thru December 31 2001

    Energy Technology Data Exchange (ETDEWEB)

    GREEN, W.E.

    2002-02-01

    The Hanford Site Air Operating Permit (AOP), Number 00-05-006, became effective on July 2, 2001. One condition contained in the AOP, ''Standard Terms and Conditions'', Section 4.3.3, is the requirement to submit semiannual reports by March 15th and August 15th each year, which are certified for truth and accuracy by a Responsible Official. This first semiannual report contains information for the period from July 2, 2001 through December 31, 2001. Hereafter, the March 15th semiannual report will contain information for the period from July 1 through December 31. The semiannual report submitted by August 15th will contain information for the period from January 1 through June 30. Copies of the semiannual reports are transmitted to the Washington State Department of Ecology (Ecology), the Washington State Department of Health (WDOH), the Benton Clean Air Authority (BCAA), and the U.S. Environmental Protection Agency (EPA), Region 10. For the applicable reporting period, AOP, ''Standard Terms and Conditions'', Section 4.3.3, identifies the following: (1) Each semiannual report will provide a reference to deviation reports submitted to the regulatory agencies as required by Section 4.5, ''Permit Deviation Reporting''. (2) Each semiannual report will consist of reports of any required monitoring not submitted previously to the agencies or a reference to reports of required monitoring that were submitted during the reporting period. (3) Each semiannual report will contain a summary of any substantiated air emission complaint investigation(s) required in Table 1.2 of AOP, Attachment 1, and issued during the reporting period (4) For all minor radioactive emission points (potential to emit <0.1 mrem to the maximally exposed individual) listed in AOP, Attachment 2. Tables 1.2, 1.3 and 2.1. each semiannual report will confirm that any required monitoring was conducted to verify low emissions during the reporting

  9. U.S. Department of Energy electric and hybrid vehicle Site Operator Program at Platte River Power Authority. Final report, July 3, 1991--August 31, 1996

    Energy Technology Data Exchange (ETDEWEB)

    Emmert, R.A.

    1996-12-31

    The Platte River Power Authority (Platte River) is a political subdivision of the state of Colorado, owned by the four municipalities of Fort Collins, Loveland, Longmont and Estes Park, Colorado. Platte River is a non-profit, publicly owned, joint-action agency formed to construct, operate and maintain generating plants, transmission systems and related facilities for the purpose of delivering to the four municipalities electric energy for distribution and resale. Platte River, as a participant in the US Department of Energy (DOE) Site Operator Program, worked to accomplish the Site Operator Program goals and objectives to field test and evaluate electric and electric-hybrid vehicles and electric vehicle systems in a real world application/environment. This report presents results of Platte River`s program (Program) during the five-years Platte River participated in the DOE Site Operator Program. Platte River participated in DOE Site Operator Program from July 3, 1991 through August 31, 1996. During its Program, Platte River conducted vehicle tests and evaluations, and electric vehicle demonstrations in the Front Range region of Northern Colorado. Platte River also investigated electric vehicle infrastructure issues and tested infrastructure components. Platte River`s Program objectives were as follows: evaluate the year round performance, operational costs, reliability, and life cycle costs of electric vehicles in the Front Range region of Northern Colorado; evaluate an electric vehicle`s usability and acceptability as a pool vehicle; test any design improvements or technological improvements on a component level that may be made available to PRPA and which can be retrofit into vehicles; and develop, test and evaluate, and demonstrate components to be used in charging electric vehicles.

  10. Drilling in Current-Controlled Sedimentary Environments on the Southeast African Margin - The SAFARI Pre-Site Survey Challenges on the Madagascar, Mozambique and the South African Margin

    Science.gov (United States)

    Spiess, V.; Preu, B.; Schwenk, T.; Palamenghi, L.; Schneider, R.; Zahn, R.; Hall, I.

    2009-04-01

    As part of the global conveyer belt circulation, the Agulhas, Mozambique and Madagascar Currents are guided southward along the Southeast African margin as strong contour currents, affecting local sediment mobilization, redistribution and deposition. To gain a better understanding of their evolution through time, a transect of drill sites ranging from the southern tip of Africa to Madagascar was proposed by Zahn et al. (SAFARI, IODP proposal 702). As contour currents become erosive in their vicinity, deposition may be inhibited and incoming sediment will be redistributed. To find suitable drill sites, they must be positioned strategically to provide continuous depositional records on the one hand by not not being located in the core of the current, and to record variations in current activity and strength, which requires a certain proximity to the mean current position. Furthermore, sources of sediment and their spatial and temporal variability play a role for the interpretation of accumulation rates, provenance of particles, reconstruction of current velocities and terrestrial input, which can be compared as climate indicators with marine geochemical tracers. Six different working areas, West of Capetown, Natal Valley, Limpopo Cone, Zambezi margin, Davie Ridge and N-Madagascar margin, were visited during R/V Meteor Cruises M63/1 (2005) and M75/3 (2008) to gain an understanding of sediment deposition and to select sites for the drilling proposal. Main observations of both cruises were, in contrast to the expectation of margins being predominantly shaped by fan deposition and mass wasting processes, the widespread occurrences of large scales contourite bodies, which were situated between 100 and 1500 m water depth. They appear to be independent of the mechanisms and volume of sediment input, revealing a close relationship to the acting contour currents. Accordingly, the drift bodies appear to be suitable deposits which record the activity of the currents by

  11. The 1996-2009 borehole dilatometer installations, operation, and maintenance at sites in Long Valley Caldera, CA

    Science.gov (United States)

    Myren, Glenn; Johnston, Malcolm; Mueller, Robert

    2011-01-01

    High seismicity levels with accelerating uplift (under the resurgent dome) in Long Valley caldera in the eastern Sierra Nevada from 1989 to 1997, triggered upgrades to dilational strainmeters and other instrumentation installed in the early 1980's following a series of magnitude 6 earthquakes. This included two additional high-resolution borehole strainmeters and replacement of the failed strainmeter at Devil's Postpile. The purpose of the borehole-monitoring network is to monitor crustal deformation and other geophysical parameters associated with volcanic intrusions and earthquakes in the Long Valley Caldera. Additional instrumentation was added at these sites to improve the capability of providing continuous monitoring of the magma source under the resurgent dome. Sites were selected in regions of hard crystalline rock, where the expected signals from magmatic activity were calculated to be a maximum and the probability of an earthquake of magnitude 4 or greater is large. For the most part, the dilatometers were installed near existing arrays of surface tiltmeters, seismometers, level line, and GPS arrays. At each site, attempts are made to separate tectonic and volcanic signals from known noise sources in each instrument type. Each of these sites was planned to be a multi-parameter monitoring site, which included measurements of 3-component seismic velocity and acceleration, borehole strain, tilt, pore pressure and magnetic field. Using seismicity, geophysical knowledge, geologic and topographic maps, and geologists recommendations, lists of preliminary sites were chosen. Additional requirements were access, and telemetry constraints. When the final site choice was made, a permit was obtained from the U.S. Forest Service. Following this selection process, two new borehole sites were installed on the north and south side of the Long Valley Caldera in June of 1999. One site was located near Big Spring Campground to the east of Crestview. The second site was

  12. Distribution of methicillin-resistant coagulase-positive staphylococci (MRCoPS) in a surgical unit and cystotomy operation sites in a veterinary teaching hospital.

    Science.gov (United States)

    Fungwithaya, Punpichaya; Brikshavana, Pasakorn; Chanchaithong, Pattrarat; Prapasarakul, Nuvee

    2017-02-28

    This study aimed to investigate the spread of methicillin-resistant coagulase-positive staphylococci (MRCoPS) among veterinary staff, hand-touch sites and surgical tissue during cystotomy operations on cats and dogs that were patients, and to analyze the genetic relatedness and antimicrobial resistance profiles of the isolates. Human and environmental samples were obtained from the nasal passageways of 12 surgeons and veterinary assistants and from 29 hand-touch sites of instruments in operative units and subjected to bacterial isolation and enumeration. Swab samples were collected in triplicate from 29 dogs and three cats at the site of incision, from the incision area, from the peritoneum during surgery and from the peritoneum before suture. MRCoPS were identified by mecA gene detection and characterized by their antibiogram profile, SCCmec type and pulsed-field gel electrophoresis. Twenty-four staphylococci were isolated, derived from one veterinary assistant, 12 operating room floor areas and hand-touch sites, three dogs and one cat. Methicillin-resistant S. pseudintermedius (MRSP) was found on an electric clipper and rebreathing circuits in the operating room. Three dogs were positive for MRSP during surgery, and one methicillin-resistant S. aureus (MRSA) was detected in a cat. All MRCoPS were resistant to doxycycline, erythromycin, clindamycin and enrofloxacin, but no patients developed surgical site infections. According to their genotypic patterns, the clones obtained from the environment and human sources differed from the animal clones. Despite intensive hygienic management, a variety of MRCoPS clones were present within the surgical unit and during surgery.

  13. Amendment to the Record of Decision for the On-Post Operable Unit, Rocky Mountain Arsenal Federal Facility Site

    Data.gov (United States)

    US Fish and Wildlife Service, Department of the Interior — This decision document amends the remedy decision for the Hex Pit project of the Rocky Mountain Arsenal (RMA) Federal Facility Site. The RMA is located in southern...

  14. OPERATIONAL CIRCULAR NO2 (REV. 1) - APRIL 1998 'CONDITIONS OF ACCESS TO THE FENCED PARTS OF THE CERN SITE'

    CERN Multimedia

    Human Resources Division

    2001-01-01

    Subsidiary document 'Implementation Measures' (Rev. 2) - April 2001 The subsidiary document has been amended. Copies are available from Divisional Secretariats and at CERN card issue points. Note : Administrative and operational circulars, as well as the lists of those in force, are available for consultation on WWW : ADMINISTRATIVE CIRCULARS OPERATIONAL CIRCULARS

  15. Analysis on installation and operation of leakage current protector in rural areas%农村漏电保护器安装运行分析

    Institute of Scientific and Technical Information of China (English)

    程夏蕾; 祝明娟; 郭行干

    2012-01-01

    In the paper, the existing problems are analyzed concerning installation and operation of leakage current protector for rural distribution network in China, inclusive of the influence on graded protections caused by transformer grounding mode, three-phase unbalanced load current and the capacitive current. The measures and suggestions for correct installation and operation of leakage current protector are therefore proposed.%分析了我国农村配电网漏电保护器安装运行中存在的问题,包括农村配电台区接地方式、三相不平衡负荷与容性电流对分级保护的影响等,并提出了正确安装使用漏电保护器的措施和建议。

  16. Site Development, Operations, and Closure Plan Topical Report 5 An Assessment of Geologic Carbon Sequestration Options in the Illinois Basin. Phase III

    Energy Technology Data Exchange (ETDEWEB)

    Finley, Robert [Univ. of Illinois, Champaign, IL (United States); Payne, William [Schlumberger Carbon Services, Houston, TX (United States); Kirksey, Jim [Univ. of Illinois, Champaign, IL (United States)

    2015-06-01

    The Midwest Geological Sequestration Consortium (MGSC) has partnered with Archer Daniels Midland Company (ADM) and Schlumberger Carbon Services to conduct a large-volume, saline reservoir storage project at ADM’s agricultural products processing complex in Decatur, Illinois. The Development Phase project, named the Illinois Basin Decatur Project (IBDP) involves the injection of 1 million tonnes of carbon dioxide (CO2) into a deep saline formation of the Illinois Basin over a three-year period. This report focuses on objectives, execution, and lessons learned/unanticipated results from the site development (relating specifically to surface equipment), operations, and the site closure plan.

  17. Role of Pre-Operative Blood Transfusion and Subcutaneous Fat Thickness as Risk Factors for Surgical Site Infection after Posterior Thoracic Spine Stabilization.

    Science.gov (United States)

    Osterhoff, Georg; Burla, Laurin; Werner, Clément M L; Jentzsch, Thorsten; Wanner, Guido A; Simmen, Hans-Peter; Sprengel, Kai

    2015-06-01

    Surgical site infections (SSIs) increase morbidity and mortality rates and generate additional cost for the healthcare system. Pre-operative blood transfusion and the subcutaneous fat thickness (SFT) have been described as risk factors for SSI in other surgical areas. The purpose of this study was to assess the impact of pre-operative blood transfusion and the SFT on the occurrence of SSI in posterior thoracic spine surgery. In total, 244 patients (median age 55 y; 97 female) who underwent posterior thoracic spine fusions from 2008 to 2012 were reviewed retrospectively. Patient-specific characteristics, pre-operative hemoglobin concentration/hematocrit values, the amount of blood transfused, and the occurrence of a post-operative SSI were documented. The SFT was measured on pre-operative computed tomography scans. Surgical site infection was observed in 26 patients (11%). The SFT was 13 mm in patients without SSI and 14 mm in those with infection (p=0.195). The odds ratio for patients with pre-operative blood transfusion to present with SSI was 3.1 (confidence interval [CI] 1.4-7.2) and 2.7 (CI 1.1-6.4) when adjusted for age. There was no difference between the groups with regard to pre-operative hemoglobin concentration (p=0.519) or hematocrit (p=0.908). The SFT did not differ in the two groups. Allogeneic red blood cell transfusion within 48 h prior to surgery was an independent risk factor for SSI after posterior fusion for the fixation of thoracic spine instabilities. Pre-operative blood transfusion tripled the risk, whereas SFT had no influence on the occurrence of SSI.

  18. Final environmental assessment for the U.S. Department of Energy, Oak Ridge Operations receipt and storage of uranium materials from the Fernald Environmental Management Project site

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-06-01

    Through a series of material transfers and sales agreements over the past 6 to 8 years, the Fernald Environmental Management Project (FEMP) has reduced its nuclear material inventory from 14,500 to approximately 6,800 metric tons of uranium (MTU). This effort is part of the US Department of energy`s (DOE`s) decision to change the mission of the FEMP site; it is currently shut down and the site is being remediated. This EA focuses on the receipt and storage of uranium materials at various DOE-ORO sites. The packaging and transportation of FEMP uranium material has been evaluated in previous NEPA and other environmental evaluations. A summary of these evaluation efforts is included as Appendix A. The material would be packaged in US Department of Transportation-approved shipping containers and removed from the FEMP site and transported to another site for storage. The Ohio Field Office will assume responsibility for environmental analyses and documentation for packaging and transport of the material as part of the remediation of the site, and ORO is preparing this EA for receipt and storage at one or more sites.

  19. Annual Site Environmental Report, Department of Energy Operations at the Energy Technology Engineering Center – Area IV, Santa Susana Field Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Frazee, Brad [North Wind, Inc., Idaho Falls, ID (United States); Hay, Scott [North Wind, Inc., Idaho Falls, ID (United States); Wondolleck, John [North Wind, Inc., Idaho Falls, ID (United States); Sorrels, Earl [North Wind, Inc., Idaho Falls, ID (United States); Rutherford, Phil [North Wind, Inc., Idaho Falls, ID (United States); Dassler, David [North Wind, Inc., Idaho Falls, ID (United States); Jones, John [North Wind, Inc., Idaho Falls, ID (United States)

    2015-05-01

    This Annual Site Environmental Report (ASER) for 2014 describes the environmental conditions related to work performed for the DOE at Area IV of the Santa Susana Field Laboratory (SSFL). The ETEC, a government-owned, company-operated test facility, was located in Area IV. The operations in Area IV included development, fabrication, operation and disassembly of nuclear reactors, reactor fuel, and other radioactive materials. Other activities in the area involved the operation of large-scale liquid metal facilities that were used for testing non-nuclear liquid metal fast breeder reactor components. All nuclear work was terminated in 1988, and all subsequent radiological work has been directed toward environmental restoration and decontamination and decommissioning (D&D) of the former nuclear facilities and their associated sites. Liquid metal research and development ended in 2002. Since May 2007, the D&D operations in Area IV have been suspended by the DOE, but the environmental monitoring and characterization programs have continued. Results of the radiological monitoring program continue to indicate that there are no significant releases of radioactive material from Area IV of SSFL. All potential exposure pathways are sampled and/or monitored, including air, soil, surface water, groundwater, direct radiation, transfer of property (land, structures, waste), and recycling.

  20. Ozone monitoring in the UK (United Kingdom): A review of 1978/8. Data from monitoring sites operated by Warren Spring Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Bower, J.S.; Broughton, G.F.; Dando, M.T.

    1988-01-01

    A new national air-quality monitoring network has been established for the Department of the Environment. Its purpose is to determine rural baseline concentrations of ozone and other pollutants throughout the United Kingdom. The report describes the background to the establishment of the network, together with its present structure and instrumentation. A series of data analyses are presented and discussed, with the intention of providing a broad and preliminary overview of ozone observations at WSL-operated monitoring sites throughout the first full year of network operation. Average and peak levels of ozone during 1987/8 are quantified, seasonal and diurnal variations are determined, and high pollution periods are examined.

  1. Cubozoan Sting-Site Seawater Rinse, Scraping, and Ice Can Increase Venom Load: Upending Current First Aid Recommendations.

    Science.gov (United States)

    Yanagihara, Angel Anne; Wilcox, Christie L

    2017-03-15

    Cnidarian envenomations are the leading cause of severe and lethal human sting injuries from marine life. The total amount of venom discharged into sting-site tissues, sometimes referred to as "venom load", has been previously shown to correlate with tentacle contact length and sequelae severity. Since scraping increased venom load as measured in a direct functional assay of venom activity (hemolysis). Scraping significantly increased hemolysis by increasing cnidae discharge. For Alatina alata, increases did not occur if the tentacles were first doused with vinegar or if heat was applied. However, in Chironex fleckeri, vinegar dousing and heat treatment were less effective, and the best outcomes occurred with the use of venom-inhibiting technologies (Sting No More(®) products). Seawater rinsing, considered a "no-harm" alternative, significantly increased venom load. The application of ice severely exacerbated A. alata stings, but had a less pronounced effect on C. fleckeri stings, while heat application markedly reduced hemolysis for both species. Our results do not support scraping or seawater rinsing to remove adherent tentacles.

  2. Role of culture of postoperative drainage fluid in the prediction of infection of the surgical site after major oncological operations of the head and neck.

    Science.gov (United States)

    Candau-Alvarez, A; Linares-Sicilia, M J; Dean-Ferrer, A; Pérez-Navero, J L

    2015-02-01

    Infection of the surgical site after major oncological operations of the head and neck increases mortality and morbidity. The aim of this prospective pilot study was to assess the efficacy of culturing the exudate from the drain after cervical neck dissection to see if it predicted such infection. We studied 40/112 patients with squamous cell cancer of the head and neck who were treated during the last two years and met our inclusion criteria. Six patients developed infections (15%). Reconstruction with pedicled rather than local or microvascular flaps, duration of operation of over 7 hours, the presence of a tracheostomy, and bilateral neck dissection were considered risk factors (p=0.01). Culture of drainage fluid on postoperative day 3 that grew no pathogens predicted that the site would not become infected, with a negative predictive value of 96%. Copyright © 2014 The British Association of Oral and Maxillofacial Surgeons. Published by Elsevier Ltd. All rights reserved.

  3. Dredging Operations Technical Support Program. Evaluation of the 1980 Capping Operations at the Experimental Mud Dump Site, New York Bight Apex.

    Science.gov (United States)

    1983-10-01

    Report to U.S. Army Engineers. Neo York Distract. "’-’-" .’ 31. Fulk, R., D. Gruber and R. Wullschleger. 1975. Laboratory Study • "-" of the Release...Aug. 27, 1980 I. 1. al. d" v of Drndge *mateal Dup 730 52,w site W2215 25.? Ag. 27, 980 130 5o,,j 1. WPpIg at. WO002211 29.3 Jon . 2, 3981 To 3 m1...25 18.0 30.1 6.45 10/3 17.5 28.7 4.5 o -" 2l/6 12.o 27.52 73 92/6 -1.0 29.02 10.5 .3110 3.0 27.57 5.5 . /8 12.5 27.31 6.6 7/9 20.0 - - ( Jon s Be,&* C

  4. Optimization of operating parameters to maximize the current density without flooding at the cathode membrane interface of a PEM fuel cell using Taguchi method and genetic algorithm

    Directory of Open Access Journals (Sweden)

    S.S.L. Rao, A. Shaija, S. Jayaraj

    2014-01-01

    Full Text Available A mathematical model was developed to investigate water accumulation at the cathode membrane interface by varying different operating parameters like fuel cell operating temperature and pressure, cathode and anode humidification temperatures and cathode stoichiometry. Taguchi optimization methodology is then combined with this model to determine the optimal combination of the operating parameters to maximize current density without flooding. Results of analysis of variance (ANOVA show that fuel cell operating temperature and cathode humidification temperature are the two most significant parameters in the ratio of 56.07% and 27.89% respectively and also that higher fuel cell temperature and lower cathode humidification temperature are favourable to get the maximum current draw without flooding at the cathode membrane interface. The global optimum value of the operating parameters to maximize the current density without flooding was obtained by formulating as an optimization problem using genetic algorithm (GA. These results were compared with the results obtained using Taguchi method and it was found to be similar and slightly better.

  5. A safety assessment for proposed pump mixing operations to mitigate episodic gas releases in tank 241-SY-101: Hanford Site,Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Lentsch, J.W.

    1996-07-01

    This safety assessment addresses each of the elements required for the proposed action to remove a slurry distributor and to install, operate, and remove a mixing pump in Tank 241-SY-101,which is located within the Hanford Site, Richland, Washington.The proposed action is required as part of an ongoing evaluation of various mitigation concepts developed to eliminate episodic gas releases that result in hydrogen concentrations in the tank dome space that exceed the lower flammability limit.

  6. Safety assessment for proposed pump mixing operations to mitigate episodic gas releases in tank 241-101-SY: Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Lentsch, J.W., Westinghouse Hanford

    1996-05-16

    This safety assessment addresses each of the elements required for the proposed action to remove a slurry distributor and to install, operate, and remove a mixing pump in Tank 241-SY-101, which is located within the Hanford Site, Richland, Washington. The proposed action is required as part of an ongoing evaluation of various mitigation concepts developed to eliminate episodic gas releases that result in hydrogen concentrations in the tank dome space that exceed the lower flammability limit.

  7. Resistance switching memory operation using the bistability in current-voltage characteristics of GaN/AlN resonant tunneling diodes

    Science.gov (United States)

    Nagase, Masanori; Takahashi, Tokio; Shimizu, Mitsuaki

    2016-10-01

    Resistance switching memory operations using the bistability in the current-voltage (I-V) characteristics of GaN/AlN resonant tunneling diodes (RTDs) were investigated to realize an ultrafast nonvolatile memory operating at a picosecond time scale. Resistance switching memory operations based on electron accumulation due to intersubband transitions and electron release due to tunneling current were demonstrated with high reproducibility at room temperature when the leakage of electrons accumulating in the quantum well from the deep level in the AlN barrier was suppressed. A nonvolatile memory for the processor core in a normally off computing system is expected to be realized using the bistability in the I-V characteristics of GaN/AlN RTDs.

  8. Estimating current and future streamflow characteristics at ungaged sites, central and eastern Montana, with application to evaluating effects of climate change on fish populations

    Science.gov (United States)

    Sando, Roy; Chase, Katherine J.

    2017-03-23

    A common statistical procedure for estimating streamflow statistics at ungaged locations is to develop a relational model between streamflow and drainage basin characteristics at gaged locations using least squares regression analysis; however, least squares regression methods are parametric and make constraining assumptions about the data distribution. The random forest regression method provides an alternative nonparametric method for estimating streamflow characteristics at ungaged sites and requires that the data meet fewer statistical conditions than least squares regression methods.Random forest regression analysis was used to develop predictive models for 89 streamflow characteristics using Precipitation-Runoff Modeling System simulated streamflow data and drainage basin characteristics at 179 sites in central and eastern Montana. The predictive models were developed from streamflow data simulated for current (baseline, water years 1982–99) conditions and three future periods (water years 2021–38, 2046–63, and 2071–88) under three different climate-change scenarios. These predictive models were then used to predict streamflow characteristics for baseline conditions and three future periods at 1,707 fish sampling sites in central and eastern Montana. The average root mean square error for all predictive models was about 50 percent. When streamflow predictions at 23 fish sampling sites were compared to nearby locations with simulated data, the mean relative percent difference was about 43 percent. When predictions were compared to streamflow data recorded at 21 U.S. Geological Survey streamflow-gaging stations outside of the calibration basins, the average mean absolute percent error was about 73 percent.

  9. The operation of cost-effective on-site process for the bio-treatment of mixed municipal solid waste in rural areas.

    Science.gov (United States)

    Wu, Duo; Zhang, Chunyan; Lü, Fan; Shao, Liming; He, Pinjing

    2014-06-01

    The application of on-site waste treatment significantly reduces the need for expensive waste collection and transportation in rural areas; hence, it is considered of fundamental importance in developing countries. In this study, the effects of in-field operation of two types of mini-scale on-site solid waste treatment facilities on de-centralized communities, one using mesophilic two-phase anaerobic digestion combined with composting (TPAD, 50 kg/d) and another using decentralized composting (DC, 0.6-2 t/d), were investigated. Source-separated collection was applied to provide organic waste for combined process, in which the amount of waste showed significant seasonal variation. The highest collection amount was 0.18 kg/capital day and 0.6 kg/household day. Both sites showed good performance after operating for more than 6 months, with peak waste reduction rates of 53.5% in TPAD process and 63.2% in DC process. Additionally, the windrow temperature exceeded 55 °C for >5 days, indicating that the composting products from both facilities were safe. These results were supported by 4 days aerobic static respiration rate tests. The emissions were low enough to avoid any impact on nearby communities (distance <100 m). Partial energy could be recovered by the combined process but with complicated operation. Hence, the choice of process must be considered in case separately.

  10. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the Savannah River Site

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, G. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  11. Radiological environmental dose assessment methods and compliance dose results for 2015 operations at the savannah river site

    Energy Technology Data Exchange (ETDEWEB)

    Jannik, G. T. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Dixon, K. L. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2016-09-01

    This report presents the environmental dose assessment methods and the estimated potential doses to the offsite public from 2015 Savannah River Site (SRS) atmospheric and liquid radioactive releases. Also documented are potential doses from special-case exposure scenarios - such as the consumption of deer meat, fish, and goat milk.

  12. 75 FR 20391 - Agrium U.S., Inc., Kenai Nitrogen Operation, Including On-Site Leased Workers From NMS (Nana...

    Science.gov (United States)

    2010-04-19

    ... Workers From NMS (Nana Management Systems) and Heat & Frost Insulation, Inc., Kenai, AK; Amended Notice of... October 22, 2008 to include on- site leased workers from NMS (Nana Management Systems). The notice was... leased workers from NMS (Nana Management Systems) and Heat & Frost Insulation, Inc., Kenai, Alaska,...

  13. 78 FR 42805 - HarperCollins Publishers Distribution Operations Including On-Site Leased Workers From Action...

    Science.gov (United States)

    2013-07-17

    ..., Canteen, Bulldog Maintenance Company, Inc., Action Lift, and Krayer Detective Agency Including Off-Site... workers leased from Canteen, Bulldog Maintenance Company, Inc., Action Lift, and Krayer Detective Agency... Department is amending this certification to include workers leased from Canteen, Bulldog Maintenance...

  14. Data Collection for Current U.S. Wind Energy Projects: Component Costs, Financing, Operations, and Maintenance; January 2011 - September 2011

    Energy Technology Data Exchange (ETDEWEB)

    Martin-Tretton, M.; Reha, M.; Drunsic, M.; Keim, M.

    2012-01-01

    DNV Renewables (USA) Inc. (DNV) used an Operations and Maintenance (O&M) Cost Model to evaluate ten distinct cost scenarios encountered under variations in wind turbine component failure rates. The analysis considers: (1) a Reference Scenario using the default part failure rates within the O&M Cost Model, (2) High Failure Rate Scenarios that increase the failure rates of three major components (blades, gearboxes, and generators) individually, (3) 100% Replacement Scenarios that model full replacement of these components over a 20 year operating life, and (4) Serial Failure Scenarios that model full replacement of blades, gearboxes, and generators in years 4 to 6 of the wind project. DNV selected these scenarios to represent a broad range of possible operational experiences. Also in this report, DNV summarizes the predominant financing arrangements used to develop wind energy projects over the past several years and provides summary data on various financial metrics describing those arrangements.

  15. GENERAL: Mode shift and stability control of a current mode controlled buck-boost converter operating in discontinuous conduction mode with ramp compensation

    Science.gov (United States)

    Bao, Bo-Cheng; Xu, Jian-Ping; Liu, Zhong

    2009-11-01

    By establishing the discrete iterative mapping model of a current mode controlled buck-boost converter, this paper studies the mechanism of mode shift and stability control of the buck-boost converter operating in discontinuous conduction mode with a ramp compensation current. With the bifurcation diagram, Lyapunov exponent spectrum, time-domain waveform and parameter space map, the performance of the buck-boost converter circuit utilizing a compensating ramp current has been analysed. The obtained results indicate that the system trajectory is weakly chaotic and strongly intermittent under discontinuous conduction mode. By using ramp compensation, the buck-boost converter can shift from discontinuous conduction mode to continuous conduction mode, and effectively operates in the stable period-one region.

  16. Mode shift and stability control of a current mode controlled buck-boost converter operating in discontinuous conduction mode with ramp compensation

    Institute of Scientific and Technical Information of China (English)

    Bao Bo-Cheng; Xu Jian-Ping; Liu Zhong

    2009-01-01

    By establishing the discrete iterative mapping model of a current mode controlled buck-boost converter, this paper studies the mechanism of mode shift and stability control of the buck-boost converter operating in discontinuous conduction mode with a ramp compensation current. With the bifurcation diagram, Lyapunov exponent spectrum, timedomain waveform and parameter space map, the performance of the buck-boost converter circuit utilizing a compensating ramp current has been analysed. The obtained results indicate that the system trajectory is weakly chaotic and strongly intermittent under discontinuous conduction mode. By using ramp compensation, the buck-boost converter can shift from discontinuous conduction mode to continuous conduction mode, and effectively operates in the stable period-one region.

  17. Neutral-beam current-driven high-poloidal-beta operation of the DIII-D tokamak

    Science.gov (United States)

    Simonen, T. C.; Matsuoka, M.; Bhadra, D. K.; Burrell, K. H.; Callis, R. W.; Chance, M. S.; Chu, M. S.; Greene, J. M.; Groebner, R. J.; Harvey, R. W.; Hill, D. N.; Kim, J.; Lao, L.; Petersen, P. I.; Porter, G. D.; St. John, H.; Stallard, B. W.; Stambaugh, R. D.; Strait, E. J.; Taylor, T. S.

    1988-10-01

    Neutral-beam current-drive experiments in the DIII-D tokamak with a single null poloidal divertor are described. A plasma current of 0.34 MA has been sustained by neutral beams alone, and the energy confinement is of H-mode quality. Poloidal β values reach 3.5 without disruption or coherent magnetic activity suggesting that these plasmas may be entering the second stability regime.

  18. Operating characteristics of superconducting fault current limiter using 24kV vacuum interrupter driven by electromagnetic repulsion switch

    Energy Technology Data Exchange (ETDEWEB)

    Endo, M; Hori, T; Koyama, K; Kaiho, K; Yanabu, S [Tokyo Denki University, 2-2 Kandanishiki-chou Chiyoda-ku Tokyo 101-8457 (Japan); Yamaguchi, I; Arai, K [National Institute of Advanced Industrial Science and Technology(AIST), 1-1-1 Umezono, Tsukuba-shi, Ibaraki 305-8565 (Japan)], E-mail: yanabu@e.dendai.ac.jp

    2008-02-01

    Using a high temperature superconductor, we constructed and tested a model Superconducting Fault Current Limiter (SFCL). SFCL which has a vacuum interrupter with electromagnetic repulsion mechanism. We set out to construct high voltage class SFCL. We produced the electromagnetic repulsion switch equipped with a 24kV vacuum interrupter(VI). There are problems that opening speed becomes late. Because the larger vacuum interrupter the heavier weight of its contact. For this reason, the current which flows in a superconductor may be unable to be interrupted within a half cycles of current. In order to solve this problem, it is necessary to change the design of the coil connected in parallel and to strengthen the electromagnetic repulsion force at the time of opening the vacuum interrupter. Then, the design of the coil was changed, and in order to examine whether the problem is solvable, the current limiting test was conducted. We examined current limiting test using 4 series and 2 parallel-connected YBCO thin films. We used 12-centimeter-long YBCO thin film. The parallel resistance (0.1{omega}) is connected with each YBCO thin film. As a result, we succeed in interrupting the current of superconductor within a half cycle of it. Furthermore, series and parallel-connected YBCO thin film could limit without failure.

  19. Survey of large circular and octagonal tanks operated at Norwegian commercial smolt and post-smolt sites

    Science.gov (United States)

    A survey was conducted to determine the geometry, operating parameters, and other key features of large circular or octagonal culture tanks used to produce Atlantic salmon smolt and post-smolt at six major Norwegian Atlantic salmon production companies. A total of 55 large tanks were reported at sev...

  20. Expected load spectra of prototype Francis turbines in low-load operation using numerical simulations and site measurements

    Science.gov (United States)

    Eichhorn, M.; Taruffi, A.; Bauer, C.

    2017-04-01

    The operators of hydropower plants are forced to extend the existing operating ranges of their hydraulic machines to remain competitive on the energy market due to the rising amount of wind and solar power. Faster response times and a higher flexibility towards part- and low-load conditions enable a better electric grid control and assure therefore an economic operation of the power plant. The occurring disadvantage is a higher dynamic excitation of affected machine components, especially Francis turbine runners, due to pressure pulsations induced by unsteady flow phenomena (e.g. draft tube vortex ropes). Therefore, fatigue analysis becomes more important even in the design phase of the hydraulic machines to evaluate the static and dynamic load in different operating conditions and to reduce maintenance costs. An approach including a one-way coupled fluid-structure interaction has been already developed using unsteady CFD simulations and transient FEM computations. This is now applied on two Francis turbines with different specific speeds and power ranges, to obtain the load spectra of both machines. The results are compared to strain gauge measurements on the according Francis turbines to validate the overall procedure.

  1. Biological assessment of the effects of construction and operation of adepleted uranium hexafluoride conversion facility at the Portsmouth, Ohio,site.

    Energy Technology Data Exchange (ETDEWEB)

    Van Lonkhuyzen, R.

    2005-09-09

    The U.S. Department of Energy (DOE) Depleted Uranium Hexafluoride (DUF{sub 6}) Management Program evaluated alternatives for managing its inventory of DUF{sub 6} and issued the ''Programmatic Environmental Impact Statement for Alternative Strategies for the Long-Term Management and Use of Depleted Uranium Hexafluoride'' (DUF{sub 6} PEIS) in April 1999 (DOE 1999). The DUF{sub 6} inventory is stored in cylinders at three DOE sites: Paducah, Kentucky; Portsmouth, Ohio; and East Tennessee Technology Park (ETTP), near Oak Ridge, Tennessee. In the Record of Decision for the DUF{sub 6} PEIS, DOE stated its decision to promptly convert the DUF{sub 6} inventory to a more stable chemical form. Subsequently, the U.S. Congress passed, and the President signed, the ''2002 Supplemental Appropriations Act for Further Recovery from and Response to Terrorist Attacks on the United States'' (Public Law No. 107-206). This law stipulated in part that, within 30 days of enactment, DOE must award a contract for the design, construction, and operation of a DUF{sub 6} conversion plant at the Department's Paducah, Kentucky, and Portsmouth, Ohio, sites, and for the shipment of DUF{sub 6} cylinders stored at ETTP to the Portsmouth site for conversion. This biological assessment (BA) has been prepared by DOE, pursuant to the National Environmental Policy Act of 1969 and the Endangered Species Act of 1974, to evaluate potential impacts to federally listed species from the construction and operation of a conversion facility at the DOE Portsmouth site. The Indiana bat is known to occur in the area of the Portsmouth site and may potentially occur on the site during spring or summer. Evaluations of the Portsmouth site indicated that most of the site was found to have poor summer habitat for the Indiana bat because of the small size, isolation, and insufficient maturity of the few woodlands on the site. Potential summer habitat for the Indiana bat was

  2. Identification of the Zn2+ binding site and mode of operation of a mammalian Zn2+ transporter.

    Science.gov (United States)

    Ohana, Ehud; Hoch, Eitan; Keasar, Chen; Kambe, Taiho; Yifrach, Ofer; Hershfinkel, Michal; Sekler, Israel

    2009-06-26

    Vesicular zinc transporters (ZnTs) play a critical role in regulating Zn2+ homeostasis in various cellular compartments and are linked to major diseases ranging from Alzheimer disease to diabetes. Despite their importance, the intracellular localization of ZnTs poses a major challenge for establishing the mechanisms by which they function and the identity of their ion binding sites. Here, we combine fluorescence-based functional analysis and structural modeling aimed at elucidating these functional aspects. Expression of ZnT5 was followed by both accelerated removal of Zn2+ from the cytoplasm and its increased vesicular sequestration. Further, activity of this zinc transport was coupled to alkalinization of the trans-Golgi network. Finally, structural modeling of ZnT5, based on the x-ray structure of the bacterial metal transporter YiiP, identified four residues that can potentially form the zinc binding site on ZnT5. Consistent with this model, replacement of these residues, Asp599 and His451, with alanine was sufficient to block Zn2+ transport. These findings indicate, for the first time, that Zn2+ transport mediated by a mammalian ZnT is catalyzed by H+/Zn2+ exchange and identify the zinc binding site of ZnT proteins essential for zinc transport.

  3. Draft environmental impact statement for the siting, construction, and operation of New Production Reactor capacity. Volume 2, Sections 1-6

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    This (EIS) assesses the potential environmental impacts, both on a broad programmatic level and on a project-specific level, concerning a proposed action to provide new tritium production capacity to meet the nation`s nuclear defense requirements well into the 21st century. A capacity equivalent to that of about a 3,000-megawatt (thermal) heavy-water reactor was assumed as a reference basis for analysis in this EIS; this is the approximate capacity of the existing production reactors at DOE`s Savannah River Site. The EIS programmatic alternatives address Departmental decisions to be made on whether to build new production facilities, whether to build one or more complexes, what size production capacity to provide, and when to provide this capacity. Project-specific impacts for siting, constructing, and operating new production reactor capacity are assessed for three alternative sites: the Hanford Site near Richland, Washington; the Idaho National Engineering Laboratory near Idaho Falls, Idaho; and the Savannah River Site. For each site, the impacts of three reactor technologies (and supporting facilities) are assessed: a heavy-water reactor, a light-water reactor, and a modular high-temperature gas-cooled reactor. Impacts of the no-action alternative also are assessed. The EIS evaluates impacts related to air quality; noise levels; surface water, groundwater, and wetlands; land use; recreation; visual environment; biotic resources; historical, archaeological, and cultural resources; socioeconomics; transportation; waste management; and human health and safety. The EIS describes in detail the potential radioactive releases from new production reactors and support facilities and assesses the potential doses to workers and the general public. This volume contains the analysis of programmatic alternatives, project alternatives, affected environment of alternative sites, environmental consequences, and environmental regulations and permit requirements.

  4. On the physical processes ruling an atmospheric pressure air glow discharge operating in an intermediate current regime

    Energy Technology Data Exchange (ETDEWEB)

    Prevosto, L., E-mail: prevosto@waycom.com.ar; Mancinelli, B.; Chamorro, J. C.; Cejas, E. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600), Santa Fe (Argentina); Kelly, H. [Grupo de Descargas Eléctricas, Departamento Ing. Electromecánica, Facultad Regional Venado Tuerto (UTN), Laprida 651, Venado Tuerto (2600), Santa Fe (Argentina); Instituto de Física del Plasma (CONICET), Facultad de Ciencias Exactas y Naturales (UBA) Ciudad Universitaria Pab. I, 1428, Buenos Aires (Argentina)

    2015-02-15

    Low-frequency (100 Hz), intermediate-current (50 to 200 mA) glow discharges were experimentally investigated in atmospheric pressure air between blunt copper electrodes. Voltage–current characteristics and images of the discharge for different inter-electrode distances are reported. A cathode-fall voltage close to 360 V and a current density at the cathode surface of about 11 A/cm{sup 2}, both independent of the discharge current, were found. The visible emissive structure of the discharge resembles to that of a typical low-pressure glow, thus suggesting a glow-like electric field distribution in the discharge. A kinetic model for the discharge ionization processes is also presented with the aim of identifying the main physical processes ruling the discharge behavior. The numerical results indicate the presence of a non-equilibrium plasma with rather high gas temperature (above 4000 K) leading to the production of components such as NO, O, and N which are usually absent in low-current glows. Hence, the ionization by electron-impact is replaced by associative ionization, which is independent of the reduced electric field. This leads to a negative current-voltage characteristic curve, in spite of the glow-like features of the discharge. On the other hand, several estimations show that the discharge seems to be stabilized by heat conduction; being thermally stable due to its reduced size. All the quoted results indicate that although this discharge regime might be considered to be close to an arc, it is still a glow discharge as demonstrated by its overall properties, supported also by the presence of thermal non-equilibrium.

  5. Hanford Site Air Operating Permit Application Supplemental Information [Sec 1 Thru 5] Vol 1 Thru 3 Appendices A Thru C

    Energy Technology Data Exchange (ETDEWEB)

    CURN, B.L.

    2000-05-01

    This report documents radionuclide air emissions from the Hanford Site in 1998 and the resulting effective dose equivalent to the maximally exposed individual (MEI) member of the public. The report has been prepared in accordance with the Code of Federal Regulations, Title 40, Protection of the Environment, Part 61, National Emission Standards for Hazardous Air Pollutants (40 CFR 61), Subpart H: ''National Emission Standards for Emissions of Radionuclides Other than Radon from Department of Energy Facilities,'' and with the Washington Administrative Code Chapter 246247, Radiation Protection - Air Emissions. The federal regulations in 40 CFR 61, Subpart H, require the measurement and reporting of radionuclides emitted from Department of Energy facilities and the resulting offsite dose from those emissions. A standard of 10 mrem/yr effective dose equivalent (EDE) is imposed on them. The EDE to the MEI due to routine emissions in 1998 from Hanford Site point sources was 1.3 E-02 mrem (1.3 E-04 mSv). which is 0.13 percent of the federal standard. Chapter 246-247 of the Washington Administrative Code (WAC) requires the reporting of radionuclide emissions from all Department of Energy Hanford Site sources. The state has adopted into these regulations the 40 CFR 61 standard of 10 mrem/yr EDE. The EDE to the MEI attributable to diffuse and fugitive radionuclide air emissions from the Hanford Site in 1998 was 2.5 E-02 mrem (2.S E-04 mSv). This dose added to the dose from point sources gives a total for all sources of 3.8 E-02 mrem/yr (3.8 E-04 mSv) EDE. which is 0.38 percent of the 10 mrem/yr standard. An unplanned release on August 26, 1998, in the 300 Area of the Hanford Site resulted in a potential dose of 4.1 E-02 mrem to a hypothetical individual at the nearest point of public access to that area. This hypothetical individual was not the MEI since the wind direction on the day of the release was away from the MEI residence. The potential dose from

  6. Dark current and light illumination effects on grating formation during periodic long-term operation in photorefractive polymers

    Energy Technology Data Exchange (ETDEWEB)

    Fujihara, T. [Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Mamiya, J. [Chemical Resources Laboratory, Tokyo Institute of Technology, R1-12, 4259 Nagatsuta, Midori-ku, Yokohama 226-8503 (Japan); Kawamoto, M. [Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Nano Medical Engineering Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Sassa, T., E-mail: tsassa@riken.jp [Center for Emergent Matter Science (CEMS), RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan); Advanced Device Laboratory, RIKEN, 2-1 Hirosawa, Wako, Saitama 351-0198 (Japan)

    2014-01-14

    Photorefractive grating formation dynamics in long-timescale writing and the effects of periodic writing through the control of writing beam irradiation or electric field application were investigated using typical photorefractive polymers. Both dark current and writing beam irradiation affected grating formation dynamics. Dark current in polymers changed the effective trap density over time through deep trap filling and/or detrapping and thus affected grating formation considerably. The writing beam irradiation also affected grating development in the presence of an electric field owing to the accumulation of filled deep traps. However, grating development recovered after the elimination of the electric field freed up the filled deep traps.

  7. Lattice QCD with the Overlap-Dirac Operator Its $\\Lambda$ Parameter, and One-Loop Renormalization of Fermionic Currents

    CERN Document Server

    Alexandrou, C; Panagopoulos, H; Vicari, E

    2000-01-01

    We compute the ratio between the scale $\\Lambda_L$ associated with a lattice formulation of QCD using the overlap-Dirac operator, and $\\Lambda_{MS-bar}$. To this end, the one-loop relation between the lattice coupling $g_0$ and the coupling renormalized in the MS-bar scheme is calculated, using the lattice background field technique. We also compute the one-loop renormalization $Z_\\Gamma$ of the two-quark operators $\\bar{\\psi} \\Gamma \\psi$, where $\\Gamma$ denotes a generic Dirac matrix. Furthermore, we study the renormalization of quark bilinears which are more extended and have better chiral properties. Finally, we present improved estimates of $Z_\\Gamma$, coming from cactus resummation and from mean field perturbation theory.

  8. Patterns in current anaesthesiological peri-operative practice for colonic resections: a survey in five northern-European countries

    DEFF Research Database (Denmark)

    Hannemann, P; Lassen, K; Hausel, J

    2006-01-01

    BACKGROUND: For colorectal surgery, evidence suggests that optimal management includes: no pre-operative fasting, a thoracic epidural analgesia continued for 2 days post-operatively, and avoidance of fluid overload. In addition, no long-acting benzodiazepines on the day of surgery and use of short...... clear liquids were permitted until 2-3 h before anaesthesia. Solid food was permitted up to 6-8 h prior to anaesthesia. In all countries more than 85% of the responders indicated that epidural anaesthesia was routinely used. Except for Denmark, long-acting benzodiazepines were still widely used. Short......-acting anaesthetics were used in all countries except Scotland where isoflurane is the anaesthetic of choice. With the exception of Denmark, intravenous fluids were used unrestrictedly. CONCLUSION: In northern Europe, most anaesthesiologists adhere to evidence-based optimal management strategies on pre...

  9. Kansas State University: DOE/KEURP Site Operator Program. Year 4, fourth quarterly report, April 1, 1995--June 30, 1995

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-08-01

    Kansas State University, in support of a DOE and Kansas Electric Utilities Research Program subject contract, continues to test, evaluate, demonstrate, and develop electric vehicle and infrastructure technology. K-State is operating two Soleq EVcort vehicles. During this reporting period both vehicles were brought back to full operational status after warranty service was completed by Soleq. Vehicle failures occurred due to three unrelated battery cable failures in addition to the replacement of one battery. Both vehicles are being operated on a routine basis. K-State, along with York Technical College, has established a relationship with Troy Design and Manufacturing (TDM) Redford, Michigan. K-State has ordered no less than four Ford Ranger electric trucks from TDM. K-State is involved in the steering committee that is monitoring and refining information to direct the design and testing of these new technology vehicles. TDM should become the first automotive manufacturer certified by one of the Big Three under their Quality Vehicle Manufacturer program. Kansas State University and the Kansas Electric Utility Research Program look forward to working with TDM on their new EV program.

  10. Waste dumping sites as a potential source of POPs and associated health risks in perspective of current waste management practices in Lahore city, Pakistan

    Energy Technology Data Exchange (ETDEWEB)

    Hafeez, Saba [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Faculty of Biological Sciences, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Mahmood, Adeel [Department of Biosciences, COMSATS Institute of Information Technology, Islamabad PO: 45550 (Pakistan); State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Syed, Jabir Hussain; Li, Jun [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China); Ali, Usman [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Faculty of Biological Sciences, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Malik, Riffat Naseem, E-mail: r_n_malik2000@yahoo.co.uk [Environmental Biology and Ecotoxicology Laboratory, Department of Environmental Sciences, Faculty of Biological Sciences, Quaid-i-Azam University, Islamabad 45320 (Pakistan); Zhang, Gan [State Key Laboratory of Organic Geochemistry, Guangzhou Institute of Geochemistry, Chinese Academy of Sciences, Guangzhou 510640 (China)

    2016-08-15

    Persistent organic pollutants (POPs) including polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and dechloran plus (DP) were analyzed in air, dust, soil and water samples from waste dump site, Lahore, Pakistan. It was revealed that PCB levels were detected higher in all matrices than PBDEs and DPs. Principal Component Analysis (PCA) showed higher usage of BDE-47, -99 and di-CBs, tri-CBs, tetra-CBs and penta-CBs. Health risk assessment of PCBs and PBDEs from soil and dust indicated low to moderate risk to the local population via different exposure pathways. It is recommended to improve current waste management practices in order to avoid emissions of contaminants and open dumping grounds should be modified into sanitary landfill. - Highlights: • The pioneer study provides the baseline data from waste dumping site from Lahore. • Dump site of Lahore is the potential source of PCBs, PBDEs and DPs in nearby environment. • Fugacity fractions indicated air to soil deposition of PCBs and PBDEs.

  11. Environmental assessment for the resiting, construction, and operation of the Environmental and Molecular Sciences Laboratory at the Hanford Site, Richland, Washington

    Energy Technology Data Exchange (ETDEWEB)

    1994-07-01

    This environmental assessment (EA) presents estimated environmental impacts from the resiting, construction, and operation of the US Department of Energy`s (DOE`s) Environmental and Molecular Sciences Laboratory (EMSL), which is proposed to be constructed and operated on land near the south boundary of the Hanford Site near Richland, Washington. The EMSL, if constructed, would be a modern research facility in which experimental, theoretical, and computational techniques can be focused on environmental restoration problems, such as the chemical and transport behavior of complex mixtures of contaminants in the environment. The EMSL design includes approximately 18,500 square meters (200,000 square feet) of floor space on a 12-hectare (30-acre) site. The proposed new site is located within the city limits of Richland in north Richland, at the south end of DOE`s 300 Area, on land to be deeded to the US by the Battelle Memorial Institute. Approximately 200 persons are expected to be employed in the EMSL and approximately 60 visiting scientists may be working in the EMSL at any given time. State-of-the-art equipment is expected to be installed and used in the EMSL. Small amounts of hazardous substances (chemicals and radionuclides) are expected to be used in experimental work in the EMSL.

  12. Work plan for the remedial investigation/feasibility study-environmental assessment for the quarry residuals operable unit at the Weldon Spring Site

    Energy Technology Data Exchange (ETDEWEB)

    1994-01-01

    The US Department of Energy (DOE) is conducting cleanup activities at the Weldon Spring site, which is located in St. Charles County, Missouri, about 48 km (30 mi) west of St. Louis. The Weldon Spring site consists of two noncontiguous areas -- the chemical plant area, which includes four raffinate pits, and the quarry. Cleanup activities at the Weldon Spring site are conducted in accordance with the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA), as amended, incorporating the values of the National Environmental Policy Act (NEPA). The contents of the documents prepared for the project are not intended to represent a statement regarding the legal applicability of NEPA to remedial actions conducted under CERCLA. In accordance with the integrated CERCLA/NEPA approach, a remedial investigation/feasibility study-environmental assessment (RI/FS-EA) is being conducted to evaluate conditions and potential responses for the quarry residuals operable unit (QROU). This operable unit consists of the following areas and/or media: the residual material remaining at the Weldon Spring quarry after removal of the pond water and bulk waste; underlying groundwater; and other media located in the surrounding vicinity of the quarry, including adjacent soil, surface water, and sediment in Femme Osage Slough. This work plan identifies the activities within the RI/FS-EA process that are being proposed to address contamination remaining at the quarry area.

  13. RDX Binds to the GABAA Receptor–Convulsant Site and Blocks GABAA Receptor–Mediated Currents in the Amygdala: A Mechanism for RDX-Induced Seizures

    Science.gov (United States)

    Williams, Larry R.; Aroniadou-Anderjaska, Vassiliki; Qashu, Felicia; Finne, Huckelberry; Pidoplichko, Volodymyr; Bannon, Desmond I.; Braga, Maria F. M.

    2011-01-01

    Background Hexahydro-1,3,5-trinitro-1,3,5-triazine (RDX) is a high-energy, trinitrated cyclic compound that has been used worldwide since World War II as an explosive in both military and civilian applications. RDX can be released in the environment by way of waste streams generated during the manufacture, use, and disposal of RDX-containing munitions and can leach into groundwater from unexploded munitions found on training ranges. For > 60 years, it has been known that exposure to high doses of RDX causes generalized seizures, but the mechanism has remained unknown. Objective We investigated the mechanism by which RDX induces seizures. Methods and results By screening the affinity of RDX for a number of neurotransmitter receptors, we found that RDX binds exclusively to the picrotoxin convulsant site of the γ-aminobutyric acid type A (GABAA) ionophore. Whole-cell in vitro recordings in the rat basolateral amygdala (BLA) showed that RDX reduces the frequency and amplitude of spontaneous GABAA receptor–mediated inhibitory postsynaptic currents and the amplitude of GABA-evoked postsynaptic currents. In extracellular field recordings from the BLA, RDX induced prolonged, seizure-like neuronal discharges. Conclusions These results suggest that binding to the GABAA receptor convulsant site is the primary mechanism of seizure induction by RDX and that reduction of GABAergic inhibitory transmission in the amygdala is involved in the generation of RDX-induced seizures. Knowledge of the molecular site and the mechanism of RDX action with respect to seizure induction can guide therapeutic strategies, allow more accurate development of safe thresholds for exposures, and help prevent the development of new explosives or other munitions that could pose similar health risks. PMID:21362589

  14. Investigation of the influence of image reconstruction filter and scan parameters on operation of automatic tube current modulation systems for different CT scanners.

    Science.gov (United States)

    Sookpeng, Supawitoo; Martin, Colin J; Gentle, David J

    2015-03-01

    Variation in the user selected CT scanning parameters under automatic tube current modulation (ATCM) between hospitals has a substantial influence on the radiation doses and image quality for patients. The aim of this study was to investigate the effect of changing image reconstruction filter and scan parameter settings on tube current, dose and image quality for various CT scanners operating under ATCM. The scan parameters varied were pitch factor, rotation time, collimator configuration, kVp, image thickness and image filter convolution (FC) used for reconstruction. The Toshiba scanner varies the tube current to achieve a set target noise. Changes in the FC setting and image thickness for the first reconstruction were the major factors affecting patient dose. A two-step change in FC from smoother to sharper filters doubles the dose, but is counterbalanced by an improvement in spatial resolution. In contrast, Philips and Siemens scanners maintained tube current values similar to those for a reference image and patient, and the tube current only varied slightly for changes in individual CT scan parameters. The selection of a sharp filter increased the image noise, while use of iDose iterative reconstruction reduced the noise. Since the principles used by CT manufacturers for ATCM vary, it is important that parameters which affect patient dose and image quality for each scanner are made clear to operator to aid in optimisation.

  15. Scale-up of counter-current chromatography: demonstration of predictable isocratic and quasi-continuous operating modes from the test tube to pilot/process scale.

    Science.gov (United States)

    Sutherland, Ian; Hewitson, Peter; Ignatova, Svetlana

    2009-12-11

    Predictable scale-up from test tube derived distribution ratios and analytical-scale sample loading optimisation is demonstrated using a model sample system of benzyl alcohol and p-cresol in a heptane:ethyl acetate:methanol:water phase system with the new 18 L Maxi counter-current chromatography centrifuge. The versatility of having a liquid stationary phase with its high loading capacity and flexible operating modes is demonstrated at two different scales by separating and concentrating target compounds using a mixture of caffeine, vanillin, naringenin and carvone using a quasi-continuous technique called intermittent counter-current extraction.

  16. Stack optimization of oxide-based RRAM for fast write speed (<1 μs) at low operating current (<10 μA)

    Science.gov (United States)

    Chen, C. Y.; Goux, L.; Fantini, A.; Degraeve, R.; Redolfi, A.; Groeseneken, G.; Jurczak, M.

    2016-11-01

    In this paper we engineer a TiN ⧹ Al2O3 ⧹ (Hf,Al)O2 ⧹ Ta2O5 ⧹ Hf Oxide Resistive Random Access Memory (OxRRAM) device for fast switching at low operation current without sacrificing the retention and endurance properties. The integrated 40 nm × 40 nm cell switches at 10 μA using write pulses shorter than 100 ns (resp. 1 μs) for Reset (resp. Set) and with amplitude speed by more than 1 decade compared to state-of-the-art OxRRAM stacks at same current level.

  17. Review Team Focused Modeling Analysis of Radial Collector Well Operation on the Hypersaline Groundwater Plume beneath the Turkey Point Site near Homestead, Florida

    Energy Technology Data Exchange (ETDEWEB)

    Oostrom, Martinus [Pacific Northwest National Lab. (PNNL), Richland, WA (United States); Vail, Lance W. [Pacific Northwest National Lab. (PNNL), Richland, WA (United States)

    2016-08-01

    Researchers at Pacific Northwest National Laboratory served as members of a U.S. Nuclear Regulatory Commission review team for the Florida Power & Light Company’s application for two combined construction permits and operating licenses (combined licenses or COLs) for two proposed new reactor units—Turkey Point Units 6 and 7. The review team evaluated the environmental impacts of the proposed action based on the October 29, 2014 revision of the COL application, including the Environmental Report, responses to requests for additional information, and supplemental information. As part of this effort, team members tasked with assessing the environmental effects of proposed construction and operation of Units 6 and 7 at the Turkey Point site reviewed two separate modeling studies that analyzed the interaction between surface water and groundwater that would be altered by the operation of radial collector wells (RCWs) at the site. To further confirm their understanding of the groundwater hydrodynamics and to consider whether certain actions, proposed after the two earlier modeling studies were completed, would alter the earlier conclusions documented by the review team in their draft environmental impact statement (EIS; NRC 2015), a third modeling analysis was performed. The third modeling analysis is discussed in this report.

  18. Behavioral Responses Of Fish To A Current-Based Hydrokinetic Turbine Under Mutlipe Operational Conditions: Final Report

    Energy Technology Data Exchange (ETDEWEB)

    Grippo, Mark A. [Argonne National Lab. (ANL), Argonne, IL (United States); Shen, Haixue [Univ. of Maine, Orono, ME (United States); Zydlewski, Gayle [Univ. of Maine, Orono, ME (United States); Rao, Shivanesh [Univ. of Maine, Orono, ME (United States); Goodwin, Andy [United States Army Engineer R & D Center, Vicksburg, MI (United States)

    2017-02-01

    There is significant interest in the interaction of aquatic organisms with current-based marine and hydrokinetic (MHK) technologies. Determining the potential impacts of MHK devices on fish behavior is critical to addressing the environmental concerns that could act as barriers to the permitting and deployment of MHK devices. To address these concerns, we use field monitoring and fish behavior models to characterize the behavioral responses of fish to MHK turbines and infer potential stimuli that may have elicited the observed behavioral changes.

  19. Patterns in current anaesthesiological peri-operative practice for colonic resections: a survey in five northern-European countries

    DEFF Research Database (Denmark)

    Hannemann, P; Lassen, K; Hausel, J;

    2006-01-01

    clear liquids were permitted until 2-3 h before anaesthesia. Solid food was permitted up to 6-8 h prior to anaesthesia. In all countries more than 85% of the responders indicated that epidural anaesthesia was routinely used. Except for Denmark, long-acting benzodiazepines were still widely used. Short......-operative fasting, thoracic epidurals and short-acting anaesthetics. However, premedication with longer-acting agents is still common. Avoidance of fluid overload has not yet found its way into daily practice. This may leave patients undergoing elective colonic surgery at risk of oversedation and excessive fluid...

  20. Draft environmental impact statement for the siting, construction, and operation of New Production Reactor capacity. Volume 3, Sections 7-12, Appendices A-C

    Energy Technology Data Exchange (ETDEWEB)

    1991-04-01

    This Environmental Impact Statement (EIS) assesses the potential environmental impacts, both on a broad programmatic level and on a project-specific level, concerning a proposed action to provide new tritium production capacity to meet the nation`s nuclear defense requirements well into the 21st century. A capacity equivalent to that of about a 3,000-megawatt (thermal) heavy-water reactor was assumed as a reference basis for analysis in this EIS; this is the approximate capacity of the existing production reactors at DOE`s Savannah River Site near Aiken, South Carolina. The EIS programmatic alternatives address Departmental decisions to be made on whether to build new production facilities, whether to build one or more complexes, what size production capacity to provide, and when to provide this capacity. Project-specific impacts for siting, constructing, and operating new production reactor capacity are assessed for three alternative sites: the Hanford Site near Richland, Washington; the Idaho National Engineering Laboratory near Idaho Falls, Idaho; and the Savannah River Site. For each site, the impacts of three reactor technologies (and supporting facilities) are assessed: a heavy-water reactor, a light-water reactor, and a modular high-temperature gas-cooled reactor. Impacts of the no-action alternative also are assessed. The EIS evaluates impacts related to air quality; noise levels; surface water, groundwater, and wetlands; land use; recreation; visual environment; biotic resources; historical, archaeological, and cultural resources; socioeconomics; transportation; waste management; and human health and safety. The EIS describes in detail the potential radioactive releases from new production reactors and support facilities and assesses the potential doses to workers and the general public. This volume contains references; a list of preparers and recipients; acronyms, abbreviations, and units of measure; a glossary; an index and three appendices.

  1. Dopaminergic modulation of sodium current in hippocampal neurons via cAMP-dependent phosphorylation of specific sites in the sodium channel alpha subunit.

    Science.gov (United States)

    Cantrell, A R; Smith, R D; Goldin, A L; Scheuer, T; Catterall, W A

    1997-10-01

    Phosphorylation of brain Na+ channel alpha subunits by cAMP-dependent protein kinase (PKA) decreases peak Na+ current in cultured brain neurons and in mammalian cells and Xenopus oocytes expressing cloned brain Na+ channels. We have studied PKA regulation of Na+ channel function by activation of D1-like dopamine receptors in acutely isolated hippocampal neurons using whole-cell voltage-clamp recording techniques. The D1 agonist SKF 81297 reversibly reduced peak Na+ current in a concentration-dependent manner. No changes in the voltage dependence or kinetics of activation or inactivation were observed. This effect was mediated by PKA, as it was mimicked by application of the PKA activator Sp-5, 6-dichloro-1-beta-D-ribofuranosylbenzimidazole-3', 5'-monophosphorothioate(cBIMPS) and was inhibited by the specific PKA inhibitor peptide PKAI5-24. cBIMPS had similar effects on type IIA brain Na+ channel alpha subunits expressed in tsA-201 cells, but no effect was observed on a mutant Na+ channel alpha subunit in which serine residues in five PKA phosphorylation sites in the intracellular loop connecting domains I and II (LI-II) had been replaced by alanine. A single mutation, S573A, similarly eliminated cBIMPS modulation. Thus, activation of D1-like dopamine receptors results in PKA-dependent phosphorylation of specific sites in LI-II of the Na+ channel alpha subunit, causing a reduction in Na+ current. Such modulation is expected to exert a profound influence on overall neuronal excitability. Dopaminergic input to the hippocampus from the mesocorticolimbic system may exert this influence in vivo.

  2. An Investigation on the Current Status of the Operation Recovery Rooms in Yazd Hospitals in 2010-2011

    Directory of Open Access Journals (Sweden)

    MR Khajeh Aminian

    2012-08-01

    Full Text Available Introduction: The recovery ward is a vital unit to care patients awaking from anesthesia and is a standard requirement for the operating room. Recovery ward is located adjacent to the operation room and is easily accessible to trained and skilled individuals. The unit must have adequate equipment for surveillance and monitoring of patients and required medication should also be provided. Methods: This study is a cross-sectional conducted in one phase through referring to hospital facilities and equipment. Physical space, personnel and their skill levels and other factors that are involved in the care of patients in the recovery have been investigated. The instruments used in this study were a check list and observe sheet which were completed by the researchers. Data analysis was conducted by SPSS software. Results: The results showed that the standards of buildings and physical space in the researched areas were mostly nonstandard. Equipment standards were to some extent in line with the criteria set by American Association of Anesthesia. Besides, some equipment was blow standard levels. Personnel standards regarding the number of nurses toward the number of recovery beds did not meet the standard criteria in most of the cases. Conclusion: The research shows that building standards in most cases are not in line with mentioned references. Undertaking equipment standards in the hospital recovery wards needs reviewing and providing controlling equipment for preventing the complications of recovery phase of anesthesia in recovery wards.

  3. Optimising the remediation of sites contaminated by the Wismut uranium mining operations using performance and risk assessment

    Energy Technology Data Exchange (ETDEWEB)

    Pelz, F.; Jakubick, A.Th.; Kahnt, R. [Wismut GmbH, Chemnitz (Germany)

    2003-07-01

    The cost and risk assessment at Wismut GmbH is performed for optimising the remediation of sites contaminated by uranium mining and milling. An iterative either probabilistic or deterministic 'top-down' model of the remediation project as an integrated system is used. Initially all relevant processes are captured in a rather abstract and simplistic way. In the course of the model development those variables and processes to which results have been shown to be sensitive are described in more detail. This approach is useful for identifying any gaps in the knowledge base that have to be filled in the course of the multi-attributive decision making. The requirement for optimisation, also with respect to socio-economic impacts, is met by including other variables in addition to costs and health risks. (authors)

  4. Recovery Efficiency Test Project: Phase 1, Activity report. Volume 1: Site selection, drill plan preparation, drilling, logging, and coring operations

    Energy Technology Data Exchange (ETDEWEB)

    Overbey, W.K. Jr.; Carden, R.S.; Kirr, J.N.

    1987-04-01

    The recovery Efficiency Test well project addressed a number of technical issues. The primary objective was to determine the increased efficiency gas recovery of a long horizontal wellbore over that of a vertical wellbore and, more specifically, what improvements can be expected from inducing multiple hydraulic fractures from such a wellbore. BDM corporation located, planned, and drilled a long radius turn horizontal well in the Devonian shale Lower Huron section in Wayne County, West Virginia, demonstrating that state-of-the-art technology is capable of drilling such wells. BDM successfully tested drilling, coring, and logging in a horizontal well using air as the circulating medium; conducted reservoir modeling studies to protect flow rates and reserves in advance of drilling operations; observed two phase flow conditions in the wellbore not observed previously; cored a fracture zone which produced gas; observed that fractures in the core and the wellbore were not systematically spaced (varied from 5 to 68 feet in different parts of the wellbore); observed that highest gas show rates reported by the mud logger corresponded to zone with lowest fracture spacing (five feet) or high fracture frequency. Four and one-half inch casting was successfully installed in the borehole and was equipped to isolate the horizontal section into eight (8) zones for future testing and stimulation operations. 6 refs., 48 figs., 10 tabs.

  5. Conditioning of BPM pickup signals for operations of the Duke storage ring with a wide range of single-bunch current

    CERN Document Server

    Wei, Xu; Sen-Lin, Huang; Wu, W Z; Hao, H; Wang, P; Wu, Y K

    2013-01-01

    The Duke storage ring is a dedicated driver for the storage ring based oscillator free-electron lasers (FELs), and the High Intensity Gamma-ray Source (HIGS). It is operated with a beam current ranging from about 1 mA to 100 mA per bunch for various operations and accelerator physics studies. High performance operations of the FEL and gamma-ray source require a stable electron beam orbit, which has been realized by the global orbit feedback system. As a critical part of the orbit feedback system, the electron beam position monitors (BPMs) are required to be able to precisely measure the electron beam orbit in a wide range of the single-bunch current. However, the high peak voltage of the BPM pickups associated with high single-bunch current degrades the performance of the BPM electronics, and can potentially damage the BPM electronics. A signal conditioning method using low pass filters is developed to reduce the peak voltage to protect the BPM electronics, and to make the BPMs capable of working with a wide ...

  6. Mitochondria sustain store-operated currents in colon cancer cells but not in normal colonic cells: reversal by non-steroidal anti-inflammatory drugs.

    Science.gov (United States)

    Hernández-Morales, Miriam; Sobradillo, Diego; Valero, Ruth A; Muñoz, Eva; Ubierna, Daniel; Moyer, Mary P; Núñez, Lucía; Villalobos, Carlos

    2017-08-15

    Tumor cells undergo a critical remodeling of intracellular Ca(2+) homeostasis that contribute to important cancer hallmarks. Store-operated Ca(2+) entry (SOCE), a Ca(2+) entry pathway modulated by mitochondria, is dramatically enhanced in colon cancer cells. In addition, most cancer cells display the Warburg effect, a metabolic switch from mitochondrial metabolism to glycolysis that provides survival advantages. Accordingly, we investigated mitochondria control of store-operated currents (SOCs) in two cell lines previously selected for representing human normal colonic cells and colon cancer cells. We found that, in normal cells, mitochondria are important for SOCs activity but they are unable to prevent current inactivation. In contrast, in colon cancer cells, mitochondria are dispensable for SOCs activation but are able to prevent the slow, Ca(2+)-dependent inactivation of SOCs. This effect is associated to increased ability of tumor cell mitochondria to take up Ca(2+) due to increased mitochondrial potential (ΔΨ) linked to the Warburg effect. Consistently with this view, selected non-steroidal anti-inflammatory drugs (NSAIDs) depolarize mitochondria, inhibit mitochondrial Ca(2+) uptake and promote SOC inactivation, leading to inhibition of both SOCE and cancer cell proliferation. Thus, mitochondria sustain store-operated currents in colon cancer cells but not in normal colonic cells and this effect is counteracted by selected NSAIDs providing a mechanism for cancer chemoprevention.

  7. Efficacy of 48-hour post-operative antibiotics prophylaxis for patients undergoing percutaneous endoscopic gastrostomy tube in preventing site infection.

    Science.gov (United States)

    Agha, Adnan; Alsaudi, Dib; Furnari, Manuele; Abdulhadi Ali, Mamdouh M; Al-Majadah, Saeed Salim Abdullah; Savarino, Vincenzo; Inferrera, Simona; Giannini, Edoardo G

    2011-06-01

    Percutaneous Endoscopic Gastrostomy (PEG) is an endoscopic procedure for placing a feeding tube into the stomach through the skin, primarily to avoid malnutrition. Malnutrition can increase the risk of wound infection, whose incidence can be decreased by using antibiotic prophylaxis. The purpose of our study was to evaluate the efficacy of a new antibiotic regimen in preventing acute post-PEG procedure complications. Ninety-seven consecutive patients were put on combined antibiotic therapy of clindamycin 600 mg and cefotaxime 1,000 mg every eight hours, starting with the insertion of the PEG tube and maintained for 48 hours. Pain/tenderness, leakage/drainage, bleeding fever, maximum white blood cells (WBC) count, pus/discharge, and PEG tube function were evaluated within 48 hours and 1 week from PEG insertion. Infection at the site of PEG insertion occurred in 3 cases (3.1%) within 48 hours and in 1 case (1.0%) within 7 days. Within 48 hours from the procedure, incidence of fever and increased WBC count was 10.3% and 9.3%, respectively, though at 7 days all were resolved. Pain, leak, and bleeding at the site of PEG placement were prevalently mild within 48 hours (74.2%, 12.4%,13.4% of patients, respectively) and subsided within 7 days (2.1%, 0%, 0%). One case (1.0%) of minor antibiotic side effect occurred. Two patients died due to complications not related to the procedure. The combined use of short-term cefotaxime and clindamycin seems to be effective in reducing incidence of acute complications due to PEG placement without increasing side-effects.

  8. Effect of pre-operative octenidine nasal ointment and showering on surgical site infections in patients undergoing cardiac surgery.

    Science.gov (United States)

    Reiser, M; Scherag, A; Forstner, C; Brunkhorst, F M; Harbarth, S; Doenst, T; Pletz, M W; Hagel, S

    2017-02-01

    To evaluate the effect of pre-operative octenidine (OCT) decolonization on surgical site infection (SSI) rates. Before-and-after cohort study. Patients undergoing an elective isolated coronary artery bypass graft (CABG) procedure: control group (1(st) January to 31(st) December 2013), N=475; intervention group (1(st) January to 31(st) December 2014), N=428. The intervention consisted of nasal application of OCT ointment three times daily, beginning on the day before surgery, and showering the night before and on the day of surgery with OCT soap. A median sternotomy was performed in 805 (89.1%) patients and a minimally invasive direct coronary artery bypass procedure was performed in 98 (10.9%) patients. Overall, there was no difference in SSI rates between the control and intervention groups (15.4% vs 13.3%, P=0.39). The rate of harvest site SSIs was significantly lower in patients in the intervention group (2.5% vs 0.5%, P=0.01). Patients who had undergone a median sternotomy in the intervention group had a significantly lower rate of organ/space sternal SSIs (1.9% vs 0.3%, P=0.04). However, there was a trend towards an increased rate of deep incisional sternal SSIs (1.2% vs 2.9%, P=0.08). Multi-variate analysis did not identify a significant protective effect of the intervention (odds ratio 0.79, 95% confidence interval 0.53-1.15, P=0.27). Pre-operative decolonization with OCT did not reduce overall SSI rates in patients undergoing an elective isolated CABG procedure, but significantly decreased harvest site and organ/space sternal SSIs. Randomized controlled trials, including controlled patient adherence to the intervention, are required to confirm these observations and to determine the clinical utility of OCT in pre-operative decolonization. Copyright © 2016 The Healthcare Infection Society. Published by Elsevier Ltd. All rights reserved.

  9. The Molecular Switch of Telomere Phages: High Binding Specificity of the PY54 Cro Lytic Repressor to a Single Operator Site

    Directory of Open Access Journals (Sweden)

    Jens Andre Hammerl

    2015-06-01

    Full Text Available Temperate bacteriophages possess a molecular switch, which regulates the lytic and lysogenic growth. The genomes of the temperate telomere phages N15, PY54 and ɸKO2 harbor a primary immunity region (immB comprising genes for the prophage repressor, the lytic repressor and a putative antiterminator. The roles of these products are thought to be similar to those of the lambda proteins CI, Cro and Q, respectively. Moreover, the gene order and the location of several operator sites in the prototype telomere phage N15 and in ɸKO2 are also reminiscent of lambda-like phages. By contrast, in silico analyses revealed the presence of only one operator (O\\(_{\\rm{R}}\\3 in PY54. The purified PY54 Cro protein was used for EMSA studies demonstrating that it exclusively binds to a 16-bp palindromic site (O\\(_{\\rm{R}}\\3 upstream of the prophage repressor gene. The O\\(_{\\rm{R}}\\3 operator sequences of PY54 and ɸKO2/N15 only differ by their peripheral base pairs, which are responsible for Cro specificity. PY54 cI and cro transcription is regulated by highly active promoters initiating the synthesis of a homogenious species of leaderless mRNA. The location of the PY54 Cro binding site and of the identified promoters suggests that the lytic repressor suppresses cI transcription but not its own synthesis. The results indicate an unexpected diversity of the growth regulation mechanisms in lambda-related phages.

  10. Biological assessment of the effects of construction and operation of a depleted uranium hexafluoride conversion facility at the Paducah, Kentucky, site.

    Energy Technology Data Exchange (ETDEWEB)

    Van Lonkhuyzen, R.

    2005-09-09

    The U.S. Department of Energy (DOE) Depleted Uranium Hexafluoride (DUF{sub 6}) Management Program evaluated alternatives for managing its inventory of DUF{sub 6} and issued the ''Programmatic Environmental Impact Statement for Alternative Strategies for the Long-Term Management and Use of Depleted Uranium Hexafluoride'' (DUF{sub 6} PEIS) in April 1999 (DOE 1999). The DUF{sub 6} inventory is stored in cylinders at three DOE sites: Paducah, Kentucky; Portsmouth, Ohio; and East Tennessee Technology Park (ETTP), near Oak Ridge, Tennessee. In the Record of Decision for the DUF{sub 6} PEIS, DOE stated its decision to promptly convert the DUF6 inventory to a more stable chemical form. Subsequently, the U.S. Congress passed, and the President signed, the ''2002 Supplemental Appropriations Act for Further Recovery from and Response to Terrorist Attacks on the United States'' (Public Law No. 107-206). This law stipulated in part that, within 30 days of enactment, DOE must award a contract for the design, construction, and operation of a DUF{sub 6} conversion plant at the Department's Paducah, Kentucky, and Portsmouth, Ohio, sites, and for the shipment of DUF{sub 6} cylinders stored at ETTP to the Portsmouth site for conversion. This biological assessment (BA) has been prepared by DOE, pursuant to the National Environmental Policy Act of 1969 (NEPA) and the Endangered Species Act of 1974, to evaluate potential impacts to federally listed species from the construction and operation of a conversion facility at the DOE Paducah site.

  11. Electric and hybrid vehicle program: Site operator program. Quarterly progress report, April--June, 1994 (3rd quarter of FY-1994)

    Energy Technology Data Exchange (ETDEWEB)

    Kiser, D.M.; Brown, H.L.

    1994-10-01

    The DOE Site Operator Program was initially established to meet the requirements of the Electric and Hybrid Vehicle Research, Development, and Demonstration Act of 1976. The Program has since evolved in response to new legislation and interests. Its mission now includes three major activity categories; advancement of Electric Vehicle (EV) technologies, development of infrastructure elements needed to support significant EV use, and increasing public awareness and acceptance of EVs. The 13 Program participants, their geographic locations, and the principal thrusts of their efforts are identified. The EV inventories of each participant are summarized. This third quarter report (FY-94) will include a summary of activities from the previous three quarters. The report section sequence has been revised to provide a more easily seen program overview, and specific operator activities are now included.

  12. 1994 Site environmental report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-07-01

    The Fernald site is a Department of Energy (DOE)-owned facility that produced high-quality uranium metals for military defense for nearly 40 years. DOE suspended production at the site in 1989 and formally ended production in 1991. Although production activities have ceased, the site continues to examine the air and liquid pathways as possible routes through which pollutants from past operations and current remedial activities may leave the site. The Site Environmental Report (SER) is prepared annually in accordance with DOE Order 5400.1, General Environmental Protection Program. This 1994 SER provides the general public as well as scientists and engineers with the results from the site`s ongoing Environmental Monitoring Program. Also included in this report is information concerning the site`s progress toward achieving full compliance with requirements set forth by DOE, U.S. Environmental Protection Agency (USEPA), and Ohio EPA (OEPA). For some readers, the highlights provided in this Executive Summary may provide sufficient information. Many readers, however, may wish to read more detailed descriptions of the information than those which are presented here. All information presented in this summary is discussed more fully in the main body of this report.

  13. Limited Field Investigation Report for Uranium Contamination in the 300 Area, 300-FF-5 Operable Unit, Hanford Site, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Bruce A.; Brown, Christopher F.; Um, Wooyong; Nimmons, Michael J.; Peterson, Robert E.; Bjornstad, Bruce N.; Lanigan, David C.; Serne, R. Jeffrey; Spane, Frank A.; Rockhold, Mark L.

    2007-11-01

    Four new CERCLA groundwater monitoring wells were installed in the 300-FF-5 Operable Unit in FY 2006 to fulfill commitments for well installations proposed in the Hanford Federal Facility Agreement and Consent Order Milestone M-24-57. Wells were installed to collect data to determine the distribution of process uranium and other contaminants of potential concern in groundwater. These data will also support uranium contaminant transport simulations and the wells will supplement the water quality monitoring network for the 300-FF-5 OU. This report supplies the information obtained during drilling, characterization, and installation of the new groundwater monitoring wells. This document also provides a compilation of hydrogeologic, geochemical, and well construction information obtained during drilling, well development, and sample collection/analysis activities.

  14. Borehole Data Package for Nine CY 2006 Polyphosphate Treatability Testing Wells, 300-FF-5 Operable Unit, Hanford Site, Washington

    Energy Technology Data Exchange (ETDEWEB)

    Williams, Bruce A.

    2007-04-12

    Nine new CERCLA groundwater monitoring wells were installed in the 300-FF-5 Operable Unit in calendar year 2006 to fulfill commitments for the EM-20 funded polyphosphate treatability test. Nine new performance monitoring wells were drilled into the uppermost unconfined aquifer, to the Hanford formation - Ringold Formation contact boundary, and completed within the permeable Hanford fm. unit 1 gravel-dominated sequence. The overall objective of the polyphosphate treatability test is to evaluate the efficacy of using polyphosphate injections to treat 300 Area uranium contaminated groundwater in situ. The objective of this work was to install the performance monitoring network surrounding the existing treatability injection well C5000 (399-1-23) in support of the implementation of a field scale demonstration of the polyphosphate technology.

  15. Dark current studies on a normal-conducting high-brightness very-high-frequency electron gun operating in continuous wave mode

    Directory of Open Access Journals (Sweden)

    R. Huang

    2015-01-01

    Full Text Available We report on measurements and analysis of a field-emitted electron current in the very-high-frequency (VHF gun, a room temperature rf gun operating at high field and continuous wave (CW mode at the Lawrence Berkeley National Laboratory (LBNL. The VHF gun is the core of the Advanced Photo-injector Experiment (APEX at LBNL, geared toward the development of an injector for driving the next generation of high average power x-ray free electron lasers. High accelerating fields at the cathode are necessary for the high-brightness performance of an electron gun. When coupled with CW operation, such fields can generate a significant amount of field-emitted electrons that can be transported downstream the accelerator forming the so-called “dark current.” Elevated levels of a dark current can cause radiation damage, increase the heat load in the downstream cryogenic systems, and ultimately limit the overall performance and reliability of the facility. We performed systematic measurements that allowed us to characterize the field emission from the VHF gun, determine the location of the main emitters, and define an effective strategy to reduce and control the level of dark current at APEX. Furthermore, the energy spectra of isolated sources have been measured. A simple model for energy data analysis was developed that allows one to extract information on the emitter from a single energy distribution measurement.

  16. Charge based, continuous compact model for the channel current in organic thin-film transistors for all regions of operation

    Science.gov (United States)

    Hain, Franziska; Graef, Michael; Iñíguez, Benjamín; Kloes, Alexander

    2017-07-01

    In general most modeling approaches for organic field-effect transistors (OFETs) are based on the typical MOSFET equations. The threshold voltage is usually a fitting parameter without relation to physical parameters hence the impact of their variability on the threshold voltage is not clear. The presented modeling approach is charge based with a continuous equation for the channel current in organic field-effect transistors from below to above threshold. The model provides a physics based parameter set related to trap states, and a compatible parameter set from a circuit designer's perspective. An expression for the threshold voltage is derived depending on the density of trap states. The model considers a power-law mobility model, parasitic contact resistances and channel length modulation effects and is verified with measurements on OFETs fabricated with small molecules.

  17. Photo-degradation and stabilization effects in operating organic photovoltaic devices by joint photo-current and morphological monitoring

    Energy Technology Data Exchange (ETDEWEB)

    Paci, B.; Generosi, A.; Rossi Albertini, V.; Perfetti, P. [ISM-C.N.R., Area di Ricerca di Tor Vergata, Via del Fosso del Cavaliere 100, 00133 Roma (Italy); de Bettignies, R. [Laboratoire Composants Solaires, CEA INES-RDI, Savoie Technolac, BP 332, 50 avenue du lac Leman, 73377 Le Bourget du Lac (France); Sentein, C. [CEA Saclay, DRT-LITEN-DSEN-GENEC-L2C, F91191 Gif-sur-Yvette (France)

    2008-07-15

    We report on a joint morphological/photoelectrical study of polymer-based photovoltaic (PV) cells in working conditions. The bulk heterojunction devices investigated are based on an active layer of poly(3-hexyl thiophene) blended with methano-fullerene, combining good PV performances with promising stability. The set-up adopted allowed the electrical properties of the device to be directly correlated to the modification of the electrode morphological parameters (thickness and roughness), which were obtained by in situ energy dispersive X-ray reflectometry (EDXR). The results of this joint time-dependent characterization demonstrated how the observed photo-induced oxidation process, limited to the buried electrode interface, is responsible for a fast decrease in the photo-current. The time-resolved measurements allowed to rule out the dynamics of the morphological changes and showed that the interface morphology may be stabilized by annealing treatments, with a significant improvement of the cell efficiency. (author)

  18. Standard Guide for On-Site Inspection and Verification of Operation of Solar Domestic Hot Water Systems

    CERN Document Server

    American Society for Testing and Materials. Philadelphia

    1987-01-01

    1.1 This guide covers procedures and test methods for conducting an on-site inspection and acceptance test of an installed domestic hot water system (DHW) using flat plate, concentrating-type collectors or tank absorber systems. 1.2 It is intended as a simple and economical acceptance test to be performed by the system installer or an independent tester to verify that critical components of the system are functioning and to acquire baseline data reflecting overall short term system heat output. 1.3 This guide is not intended to generate accurate measurements of system performance (see ASHRAE standard 95-1981 for a laboratory test) or thermal efficiency. 1.4 The values stated in SI units are to be regarded as the standard. The values given in parentheses are for information only. 1.5 This standard does not purport to address all of the safety concerns, if any, associated with its use. It is the responsibility of the user of this standard to establish appropriate safety and health practices and determine th...

  19. Human Health and Ecological Risk Assessment for the Operation of the Explosives Waste Treatment Facility at Site 300 of the Lawrence Livermore National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Gallegos, G; Daniels, J; Wegrecki, A

    2007-10-01

    This document contains the human health and ecological risk assessment for the Resource Recovery and Conservation Act (RCRA) permit renewal for the Explosives Waste Treatment Facility (EWTF). Volume 1 is the text of the risk assessment, and Volume 2 (provided on a compact disc) is the supporting modeling data. The EWTF is operated by the Lawrence Livermore National Laboratory (LLNL) at Site 300, which is located in the foothills between the cities of Livermore and Tracy, approximately 17 miles east of Livermore and 8 miles southwest of Tracy. Figure 1 is a map of the San Francisco Bay Area, showing the location of Site 300 and other points of reference. One of the principal activities of Site 300 is to test what are known as 'high explosives' for nuclear weapons. These are the highly energetic materials that provide the force to drive fissionable material to criticality. LLNL scientists develop and test the explosives and the integrated non-nuclear components in support of the United States nuclear stockpile stewardship program as well as in support of conventional weapons and the aircraft, mining, oil exploration, and construction industries. Many Site 300 facilities are used in support of high explosives research. Some facilities are used in the chemical formulation of explosives; others are locations where explosive charges are mechanically pressed; others are locations where the materials are inspected radiographically for such defects as cracks and voids. Finally, some facilities are locations where the machined charges are assembled before they are sent to the onsite test firing facilities, and additional facilities are locations where materials are stored. Wastes generated from high-explosives research are treated by open burning (OB) and open detonation (OD). OB and OD treatments are necessary because they are the safest methods for treating explosives wastes generated at these facilities, and they eliminate the requirement for further handling

  20. A new method to characterize power quality disturbances resulting from expulsion and current-limiting fuse operation

    Directory of Open Access Journals (Sweden)

    Neil A. Ortiz-Silva

    2015-01-01

    Full Text Available Este trabajo presenta un nuevo método para la caracterización y el diagnóstico de perturbaciones eléctricas causas por la oper ación de fusibles en los sistemas de distr ibución de energí a eléctrica. Se propone un conjunto de descriptores con el propósito de cuan tificar las características propias de las distorsiones originadas por la o peración de fusibles de expulsión y limitadores de corriente. Para seleccionar los descriptores con los mejore s perfiles clasificatorios se re aliza un análisis estadístico multivariable y a través de algor itmos de aprendizaje automático se seleccionan los umbrales de decisión óptimos para los mismos. A partir de la simulación en ATP-EMTP se obtienen señales de tensión y corriente de la ope ración de fusibles, así como al gunos registros de eventos reale s, para en conjunto ser utiliza dos en la validación del nuevo algoritmo pr opuesto, obteniéndose un ópti mo desempeño y eficacia en los resultados. El algoritmo fue imp lementado en Matlab y los requerimientos computacionales son mínimos.

  1. Initial operation and current status of the Fermilab DZero VMEbus-based hardware control and monitor system

    Energy Technology Data Exchange (ETDEWEB)

    Goodwin, R.; Florian, R.; Johnson, M.; Jones, A.; Shea, M.

    1989-11-01

    DZero is a large colliding beams detector at Fermilab. The control system for this detector includes twenty-five VMEbus-based 68020 computers interconnected using the IEEE-802.5 Token Ring local area network. In operation, the system will monitor about fifteen thousand analog channels and several thousand digital status bits, interfaced to the 68020 computers by the MIL-1553 multiplexed data bus. In addition, the VMEbus control system uses a memory-mapped multi-VMEbus interconnect to download parameters to more than one hundred VMEbus data crates in the experiment. Remote host computers can then read and set memory in the detector crates over the network by accessing memory in the control crates. This is an extremely useful feature during the construction phase, because low level diagnostics and testing of all the detector electronics can be done over the Token Ring network using either IBM-PC compatible computers or the laboratory-wide VAX system. The VMEbus control system hardware is now being installed in the DZero movable counting house. Installation is expected to be complete later this year. 4 refs., 2 figs.

  2. Waste dumping sites as a potential source of POPs and associated health risks in perspective of current waste management practices in Lahore city, Pakistan.

    Science.gov (United States)

    Hafeez, Saba; Mahmood, Adeel; Syed, Jabir Hussain; Li, Jun; Ali, Usman; Malik, Riffat Naseem; Zhang, Gan

    2016-08-15

    Persistent organic pollutants (POPs) including polychlorinated biphenyls (PCBs), polybrominated diphenyl ethers (PBDEs) and dechloran plus (DP) were analyzed in air, dust, soil and water samples from waste dump site, Lahore, Pakistan. It was revealed that PCB levels were detected higher in all matrices than PBDEs and DPs. Principal Component Analysis (PCA) showed higher usage of BDE-47, -99 and di-CBs, tri-CBs, tetra-CBs and penta-CBs. Health risk assessment of PCBs and PBDEs from soil and dust indicated low to moderate risk to the local population via different exposure pathways. It is recommended to improve current waste management practices in order to avoid emissions of contaminants and open dumping grounds should be modified into sanitary landfill.

  3. First Dark Matter Search Results from a 4-kg CF$_3$I Bubble Chamber Operated in a Deep Underground Site

    Energy Technology Data Exchange (ETDEWEB)

    Behnke, E.; /Indiana U., South Bend; Behnke, J.; /Indiana U., South Bend; Brice, S.J.; /Fermilab; Broemmelsiek, D.; /Fermilab; Collar, J.I.; /Chicago U., EFI; Conner, A.; /Indiana U., South Bend; Cooper, P.S.; /Fermilab; Crisler, M.; /Fermilab; Dahl, C.E.; /Chicago U., EFI; Fustin, D.; /Chicago U., EFI; Grace, E.; /Indiana U., South Bend /Fermilab

    2012-04-01

    New data are reported from the operation of a 4.0 kg CF{sub 3}I bubble chamber in the 6800 foot deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha decay background events from single nuclear recoils has been confirmed, with a lower bound of >99.3% rejection of alpha decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses >20 GeV/c{sup 2} and demonstrates significant sensitivity for spin-independent interactions.

  4. First Dark Matter Search Results from a 4-kg CF$_3$I Bubble Chamber Operated in a Deep Underground Site

    CERN Document Server

    Behnke, E; Brice, S J; Broemmelsiek, D; Collar, J I; Conner, A; Cooper, P S; Crisler, M; Dahl, C E; Fustin, D; Grace, E; Hall, J; Hu, M; Levine, I; Lippincott, W H; Moan, T; Nania, T; Ramberg, E; Robinson, A E; Sonnenschein, A; Szydagis, M; Vázquez-Jáuregui, E

    2012-01-01

    New data are reported from the operation of a 4.0 kg CF$_{3}$I bubble chamber in the 6800 foot deep SNOLAB underground laboratory. The effectiveness of ultrasound analysis in discriminating alpha decay background events from single nuclear recoils has been confirmed, with a lower bound of $>$99.3% rejection of alpha decay events. Twenty single nuclear recoil event candidates and three multiple bubble events were observed during a total exposure of 553 kg-days distributed over three different bubble nucleation thresholds. The effective exposure for single bubble recoil-like events was 437.4 kg-days. A neutron background internal to the apparatus, of known origin, is estimated to account for five single nuclear recoil events and is consistent with the observed rate of multiple bubble events. This observation provides world best direct detection constraints on WIMP-proton spin-dependent scattering for WIMP masses $>$20 GeV/c$^{2}$ and demonstrates significant sensitivity for spin-independent interactions.

  5. Kansas State University DOE/KEURP Site Operator Program. Year 3, Third quarter report, January 1, 1994--March 31, 1994

    Energy Technology Data Exchange (ETDEWEB)

    Hague, J.R.

    1994-05-01

    Formed on July 15, 1981, the goal of this program is to undertake applied research and development projects that may enhance reliability and minimize the cost of electric service in Kansas. The Kansas Electric Utilities Research Program (KEURP) is a contractual joint venture between six major electric utilities that serve the residents of the State of Kansas. The establishment of KEURP was made possible by the Kansas Corporation Commission (KCC). The KCC allowed Kansas electric utilities to include research and development (R & D) costs in their operating expenses, including dues to the Electric Power Research Institute (EPRI). Kansas universities play a unique role in KEURP with representation on the executive, technical and advisory committees of the program. The universities receive significant direct and indirect support from KEURP through direct funded projects as well as KEURP/EPRI co-funded projects. KEURP is working with EPRI researchers on projects to develop or expand Kansans knowledge and expertise in the fields of high technology and economic development. KEURP is a major source of funding in the electric/hybrid vehicle demonstration program.

  6. Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities at surface monitoring sites

    Directory of Open Access Journals (Sweden)

    Y. Matsumi

    2010-04-01

    Full Text Available Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities were developed in two independent systems: one utilizing a grating-based desktop optical spectrum analyzer (OSA with a resolution enough to resolve rotational lines of CO2 and CH4 in the region of 1565–1585 and 1674–1682 nm, respectively; the other is an application of an optical fiber Fabry-Perot interferometer (FFPI to the CO2 column density. Direct sunlight was collimated via a small telescope installed on a portable sun tracker and then transmitted through an optical fiber into the OSA or the FFPI for optical analysis. The near infrared spectra of the OSA were retrieved by a least squares spectral fitting algorithm. The CO2 and CH4 column densities deduced were in excellent agreement with those measured by a Fourier transform spectrometer with high resolution. The rovibronic lines in the wavelength region of 1570–1575 nm were analyzed by the FFPI. The I0 and I values in the Beer-Lambert law equation to obtain CO2 column density were deduced by modulating temperature of the FFPI, which offered column CO2 with the statistical error less than 0.2% for six hours measurement.

  7. Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities at surface monitoring sites

    Directory of Open Access Journals (Sweden)

    I. Morino

    2010-08-01

    Full Text Available Remotely operable compact instruments for measuring atmospheric CO2 and CH4 column densities were developed in two independent systems: one utilizing a grating-based desktop optical spectrum analyzer (OSA with a resolution enough to resolve rotational lines of CO2 and CH4 in the regions of 1565–1585 and 1674–1682 nm, respectively; the other is an application of an optical fiber Fabry-Perot interferometer (FFPI to obtain the CO2 column density. Direct sunlight was collimated via a small telescope installed on a portable sun tracker and then transmitted through an optical fiber into the OSA or the FFPI for optical analysis. The near infrared spectra of the OSA were retrieved by a least squares spectral fitting algorithm. The CO2 and CH4 column densities deduced were in excellent agreement with those measured by a Fourier transform spectrometer with high resolution. The rovibronic lines in the wavelength region of 1570–1575 nm were analyzed by the FFPI. The I0 and I values in the Beer-Lambert law equation to obtain CO2 column density were deduced by modulating temperature of the FFPI, which offered column CO2 with the statistical error less than 0.2% for six hours measurement.

  8. The first Italian Superconducting Fault Current Limiter: Results of the field testing experience after one year operation

    Science.gov (United States)

    Martini, L.; Bocchi, M.; Ascade, M.; Valzasina, A.; Rossi, V.; Ravetta, C.; Angeli, G.

    2014-05-01

    Ricerca sul Sistema Energetico S.p.A. (RSE) has been gaining a relevant experience in the simulation, design and installation of resistive-type Superconducting Fault Current Limiter (SFCL) devices for more than five years in the framework of a R&D national project funded by the Ricerca di Sistema (RdS). The most recent outcome of this research activity is the installation of a resistive-type BSCCO-based 9 kV / 3.4 MVA SFCL device in a single feeder branch of the Medium Voltage (MV) distribution network managed by A2A Reti Elettriche S.p.A (A2A) in the Milano area. This installation represents the first SFCL successfully installed in Italy. In this paper, we report on the main outcomes after a more than 1-year long steady-state field testing activity. The design of an upgraded device to be installed in the same substation has already been initiated: the new SFCL will allow to protect four different feeders, therefore implying a device upgrade up to 15.6 MVA.

  9. Major operations and activities

    Energy Technology Data Exchange (ETDEWEB)

    Black, D.G.

    1995-06-01

    This section of the 1994 Hanford Site Environmental Report summarizes the major operations and activities on the site. These operations and activities include site management, waste management, environmental restoration and corrective actions, and research and technology development.

  10. Use of New Commercial, Off-the-Shelf, High-Definition Structure Scanning Fathometer/Depth Finder For Coastal Current Survey Operations

    Science.gov (United States)

    Roggenstein, E. B.; Gray, G.

    2013-12-01

    The National Oceanic and Atmospheric Administration (NOAA) National Ocean Service (NOS) Center for Operational Oceanographic Products and Services (COOPS) manages three national observing system programs. These are the National Water level Observation Network (NWLON) (210 stations), the 23 NOAA/Physical Oceanographic Real-Time Systems (PORTS), and National Currents Observing Program (NCOP) (approximately 70 deployments/year). In support of its mission COOPS operates and maintains a number of small boats. During vessel operations, side-scan sonar data are at times needed to provide information about bottom structure for future work in the area. For example, potential hazards, obstructions, or bottom morphology features that have not been identified on localized charts for a given area could be used to inform decisions on planned installations. Side-scan sonar capability is also important when attempting to reacquire bottom mounts that fail to surface at the conclusion of a current meter survey. Structure mapping and side-scan capabilities have been added to recent consumer-level, commercial, off-the-shelf fathometers, generally intended for recreational, commercial fishing, and diving applications. We are proposing to investigate these systems' viability for meeting survey requirements. We assess their ability to provide a flexible alternative to research/commercial oceanographic level side-scan system at a significant cost savings. Such systems could provide important information to support scientific missions that require qualitative seafloor imagery.

  11. Determining best practices in reconnoitering sites for habitability potential on Mars using a semi-autonomous rover: A GeoHeuristic Operational Strategies Test

    Science.gov (United States)

    Yingst, R. A.; Berger, J.; Cohen, B. A.; Hynek, B.; Schmidt, M. E.

    2017-03-01

    We tested science operations strategies developed for use in remote mobile spacecraft missions, to determine whether reconnoitering a site of potential habitability prior to in-depth study (a walkabout-first strategy) can be a more efficient use of time and resources than the linear approach commonly used by planetary rover missions. Two field teams studied a sedimentary sequence in Utah to assess habitability potential. At each site one team commanded a human "rover" to execute observations and conducted data analysis and made follow-on decisions based solely on those observations. Another team followed the same traverse using traditional terrestrial field methods, and the results of the two teams were compared. Test results indicate that for a mission with goals similar to our field case, the walkabout-first strategy may save time and other mission resources, while improving science return. The approach enabled more informed choices and higher team confidence in choosing where to spend time and other consumable resources. The walkabout strategy may prove most efficient when many close sites must be triaged to a smaller subset for detailed study or sampling. This situation would arise when mission goals include finding, identifying, characterizing or sampling a specific material, feature or type of environment within a certain area.

  12. Data management implementation plan for the site characterization of the Waste Area Grouping 1 Groundwater Operable Unit at Oak Ridge National Laboratory

    Energy Technology Data Exchange (ETDEWEB)

    Ball, T.S.; Nickle, E.B.

    1994-10-01

    The Waste Area Grouping (WAG) 1 Groundwater Operable Unit (OU) at Oak Ridge National Laboratory (ORNL) in Oak Ridge, Tennessee, is undergoing a site characterization. This project is not mandated by the Comprehensive Environmental Response, Compensation, and Liability Act (CERCLA); therefore, no formalized meetings for data quality objective (DQO) development were held. Internally, DQOs were generated by the project team based on the end uses of the data to be collected. The 150-acre WAG 1 is contained within the ORNL security area. It includes all of the former ORNL radioisotope research, production, and maintenance facilities; former waste management areas; and some former administrative facilities. The goal of the WAG 1 Groundwater Site Characterization is to provide the necessary data on the nature and extent of groundwater contamination with an acceptable level of uncertainty to support the selection of remedial alternatives and to identify additional data needs for future actions. Primary objectives for the site characterization are: (1) To identify and characterize contaminant migration pathways based on the collection of groundwater data; (2) to identify sources of groundwater contamination and evaluate remedial actions which could be implemented to control or eliminate these sources; and (3) To conduct groundwater monitoring in support of other OUs in WAG 1 and the ORNL Groundwater OU.

  13. Brief Introduction of Operation and Management of Evacuation Site after Earthquake%地震后应急避难场所的运行管理

    Institute of Scientific and Technical Information of China (English)

    王海鹰; 买莹; 董赟; 杨国宾

    2014-01-01

    Based on operation and management of evacuation site of M 7. 1 earthquake in Yushu in 2010, M 5. 7 and 5. 6 earthquakes in Yiliang in 2012, M 7. 0 earthquake in Lushan in 2013 and M 6. 6 earthquake in Minxian and Zhangxian in 2013, this article compares the differences between commanding and coordination of evacuation site, management of evacuees, providing of emergency materials, temporary accommodation of evacuees, medical treatment, sanitation and convenience service for public in four cases, then summarizes several experiences and lessons, so that it can provide references on operation and management of evacuation site in earthquake emergency phase in the future.%在对2010年青海玉树7.1级地震、2012年云南彝良5.7、5.6级地震、2013年四川芦山7.0级地震和甘肃岷县漳县6.6级地震应急避难和灾民安置工作进行现场调查和访谈的基础上,从避难场所指挥管理、避难人员管理、应急物资发放、灾民临时住宿、避难场所医疗防疫、卫生和便民服务等方面进行了对比研究,总结经验教训,为未来可能发生的地震应急避难和避难场所的运行管理工作提供参考和借鉴。

  14. Current distribution, habitat, and status of Category 2 candidate plant species on and near the U.S. Department of Energy's Nevada Test Site

    Energy Technology Data Exchange (ETDEWEB)

    Blomquist, Kevin W. [EG& G Energy Measurements, Gaithersburg, MD (United States); Lindemann, Tim A. [EG& G Energy Measurements, Gaithersburg, MD (United States); Lyon, Glen E. [EG& G Energy Measurements, Gaithersburg, MD (United States); Steen, Dan C. [EG& G Energy Measurements, Gaithersburg, MD (United States); Wills, Cathy A. [EG& G Energy Measurements, Gaithersburg, MD (United States); Flick, Sarah A. [EG& G Energy Measurements, Gaithersburg, MD (United States); Ostler, W. Kent [EG& G Energy Measurements, Gaithersburg, MD (United States)

    1995-12-31

    Results of surveys conducted between 1991 and 1995 were used to document the distribution and habitat of 11 Category 2 candidate plant species known to occur on or near the Nevada Test Site (NTS). Approximately 200 areas encompassing about 13,000 ha were surveyed. Distributions of all species except Frasera-pahutensis and Phaceliaparishii were increased, and the ranges of Camissonia megalantha, Galium hilendiae ssp. kingstonense, Penstemon albomarginatus, and Penstemon pahutensis were expanded. The status of each species was assessed based on current distribution population trends, and potential threats. Recommendations were made to reclassi& the following five species to Category 3C: Arctomecon merriamii, F. pahutensis, P. pahutensis, Phacelia beatleyae, and Phaceliaparishii. Two species, C. megalantha and Cymopterus ripIeyi var. saniculoides, were recommended for reclassification to Category 3B status. No recommendation was made to reclassify Astragalus funereus, G. hilendiae ssp. kingstonense, P. albomarginatus, or Penstemon fruticiformis var. amargosae from their current Category 2 status. Populations of these four species are not threatened on NTS, but the NTS populations represent only a.small portion of each species’ range and the potential threats of mining or grazing activities off NTS on these species was notassessed. Conservation measures recommended included the development of an NTS ecosystem conservation plan, continued conduct of preactivity and plant surveys on NTS, and protection of plant type localities on NTS.

  15. Quaternary clay mineralogy in the northern South China Sea (ODP Site 1146)--Implications for oceanic current transport and East Asian monsoon evolution

    Institute of Scientific and Technical Information of China (English)

    LIU Zhifei(刘志飞); Alain Trentesaux; Steven C. Clemens; WANG Pinxian(汪品先)

    2003-01-01

    Measurement of clay mineralogy at ODP Site 1146 in the northern South China Sea (SCS) indicates that illite, chlorite, and kaolinite contents increased during glacials and smectite content increased during interglacials. The smectite/(illite+chlorite) ratio and the smectite abundance were determined as mineralogical indicators for the East Asian monsoon evolution. At a 10 ka timescale, prevailing southeasterly surface oceanic currents during interglacials transported more smectite from the south and east areas to the north, showing a strengthened summer monsoon circulation, whereas dominated counter-clockwise surface currents during glacials carried more illite and chlorite from Taiwan as well as from the Yangtze River via the Luzon Strait to the northern SCS, indicating a strongly intensified winter monsoon. Based on a 100 ka timescale, a linear correlation between the smectite/(illite+chlorite) ratio and the sedimentation rate reflects that the winter monsoon has prevailed in the northern SCS in the intervals 2000-1200 ka and 400-0 ka and the summer monsoon did the same in the interval 1200-400 ka. The evolution of the summer monsoon provides an almost linear response to the summer insolation of Northern Hemisphere, implying an astronomical forcing of the East Asian monsoon evolution.

  16. Using of explosive technologies for development of a compact current-limiting device for operation on 110 kV class systems

    Science.gov (United States)

    Shurupov, A. V.; Shurupov, M. A.; Kozlov, A. A.; Kotov, A. V.

    2016-11-01

    This paper considers the possibility of creating on new physical principles a highspeed current-limiting device (CLD) for the networks with voltage of 110 kV, namely, on the basis of the explosive switching elements. The device is designed to limit the steady short-circuit current to acceptable values for the time does not exceed 3 ms at electric power facilities. The paper presents an analysis of the electrical circuit of CLD. The main features of the scheme are: a new high-speed switching element with high regenerating voltage; fusible switching element that enables to limit the overvoltage after sudden breakage of network of the explosive switch; non-inductive resistor with a high heat capacity and a special reactor with operating time less than 1 s. We analyzed t