WorldWideScience

Sample records for current reference sources

  1. Reference Sources in Chemistry

    OpenAIRE

    Sthapit, Dilip Man

    1995-01-01

    Information plays an important role in the development of every field. Therefore a brief knowledge regarding information sources is necessary to function in any field. There are many information sources about scientific and technical subjects. In this context there are many reference sources in Chemistry too. Chemistry is one important part of the science which deals with the study of the composition of substances and the chemical changes that they undergo. The purpose of this report is...

  2. Source Reference File

    Data.gov (United States)

    Social Security Administration — This file contains a national set of names and contact information for doctors, hospitals, clinics, and other facilities (known collectively as sources) from which...

  3. High current ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-06-01

    The concept of high current ion source is both relative and evolutionary. Within the domain of one particular kind of ion source technology a current of microamperers might be 'high', while in another area a current of 10 Amperes could 'low'. Even within the domain of a single ion source type, what is considered high current performance today is routinely eclipsed by better performance and higher current output within a short period of time. Within their fields of application, there is a large number of kinds of ion sources that can justifiably be called high current. Thus, as a very limited example only, PIGs, Freemen sources, ECR sources, duoplasmatrons, field emission sources, and a great many more all have their high current variants. High current ion beams of gaseous and metallic species can be generated in a number of different ways. Ion sources of the kind developed at various laboratories around the world for the production of intense neutral beams for controlled fusion experiments are used to form large area proton deuteron beams of may tens of Amperes, and this technology can be used for other applications also. There has been significant progress in recent years in the use of microwave ion sources for high current ion beam generation, and this method is likely to find wide application in various different field application. Finally, high current beams of metal ions can be produced using metal vapor vacuum arc ion source technology. After a brief consideration of high current ion source design concepts, these three particular methods are reviewed in this paper

  4. Modulation of Current Source Inverter

    Directory of Open Access Journals (Sweden)

    Golam Reza Arab Markadeh

    2011-04-01

    Full Text Available Direct torque control with Current Source Inverter (CSI instead of voltage source inverter is so appropriate because of determining the torque of induction motor with machine current and air gap flux. In addition, Space-Vector Modulation (SVM is a more proper method for CSI because of low order harmonics reduction, lower switching frequency and easier implementation. This paper introduces the SVM method for CSI and uses the proposed inverter for vector control of an induction motor. The simulation results illustrate fast dynamic response and desirable torque and speed output. Fast and accurate response to changes of speed and load torque reference completely proves the prominence of this method.

  5. The Spallation Neutron Source RF Reference System

    CERN Document Server

    Piller, Maurice; Crofford, Mark; Doolittle, Lawrence; Ma, Hengjie

    2005-01-01

    The Spallation Neutron Source (SNS) RF Reference System includes the master oscillator (MO), local oscillator(LO) distribution, and Reference RF distribution systems. Coherent low noise Reference RF signals provide the ability to control the phase relationships between the fields in the front-end and linear accelerator (linac) RF cavity structures. The SNS RF Reference System requirements, implementation details, and performance are discussed.

  6. Current status of ion source development

    International Nuclear Information System (INIS)

    Ishikawa, Junzo

    2001-01-01

    In this report, the current status of ion source development will be discussed. In September 2001, the 9th International Conference on Ion Sources (ICIS01) was held in Oakland, U.S.A. Referring the talks presented at ICIS01, recent topics in the ion source research fields will be described. (author)

  7. Reference Sources: Little Known to Basic

    Science.gov (United States)

    RQ, 1970

    1970-01-01

    This article lists seventy-eight reference sources, and is divided into the following four sections: (1) Useful But Little-Known Reference Tools by John Fetros, (2) The Statesman's Year-Book by James Becker, (3) Single Volume Scientific Encyclopedias by Jack Clarke and (4) Ten Basic Sources of Business and Economic Statistics by James Woy. (MF)

  8. High current density ion source

    International Nuclear Information System (INIS)

    King, H.J.

    1977-01-01

    A high-current-density ion source with high total current is achieved by individually directing the beamlets from an electron bombardment ion source through screen and accelerator electrodes. The openings in these screen and accelerator electrodes are oriented and positioned to direct the individual beamlets substantially toward a focus point. 3 figures, 1 table

  9. Archaeology: A Guide to Reference Sources.

    Science.gov (United States)

    Morrison, Doreen, Comp.

    This bibliographic guide lists reference sources available at McGill University for research in prehistory and non-classical archaeology. No exclusively biographical sources have been included, but many of the encyclopedias and handbooks contain biographical information and are annotated accordingly. Titles are listed in the following categories:…

  10. Canadian Reference Sources 1980--A Selection.

    Science.gov (United States)

    Ryder, Dorothy E.

    1981-01-01

    Provides a bibliography of 52 reference sources and 24 new editions and supplements, excluding annuals. Topics include science and technology, art, history, university courses, regional information, native languages, museums, law, geography, Canadian culture, dissertations, sports, antiques, botany, and a variety of directories. (CHC)

  11. High current polarized electron source

    Science.gov (United States)

    Suleiman, R.; Adderley, P.; Grames, J.; Hansknecht, J.; Poelker, M.; Stutzman, M.

    2018-05-01

    Jefferson Lab operates two DC high voltage GaAs photoguns with compact inverted insulators. One photogun provides the polarized electron beam at the Continuous Electron Beam Accelerator Facility (CEBAF) up to 200 µA. The other gun is used for high average current photocathode lifetime studies at a dedicated test facility up to 4 mA of polarized beam and 10 mA of un-polarized beam. GaAs-based photoguns used at accelerators with extensive user programs must exhibit long photocathode operating lifetime. Achieving this goal represents a significant challenge for proposed facilities that must operate in excess of tens of mA of polarized average current. This contribution describes techniques to maintain good vacuum while delivering high beam currents, and techniques that minimize damage due to ion bombardment, the dominant mechanism that reduces photocathode yield. Advantages of higher DC voltage include reduced space-charge emittance growth and the potential for better photocathode lifetime. Highlights of R&D to improve the performance of polarized electron sources and prolong the lifetime of strained-superlattice GaAs are presented.

  12. Awareness and perception of reference sources and services by ...

    African Journals Online (AJOL)

    ... e-mail, telephone and social media (e.g. facebook). It was also revealed that 228 (70.45%) have good knowledge of what reference source are; 192 (59.08%) have good understanding of what reference services are, and 241 (74.15%) make use of reference sources in the Federal University of Technology, Owerri library.

  13. A Hybrid, Current-Source/Voltage-Source Power Inverter Circuit

    DEFF Research Database (Denmark)

    Trzynadlowski, Andrzej M.; Patriciu, Niculina; Blaabjerg, Frede

    2001-01-01

    A combination of a large current-source inverter and a small voltage-source inverter circuits is analyzed. The resultant hybrid inverter inherits certain operating advantages from both the constituent converters. In comparison with the popular voltage-source inverter, these advantages include...... reduced switching losses, improved quality of output current waveforms, and faster dynamic response to current control commands. Description of operating principles and characteristics of the hybrid inverter is illustrated with results of experimental investigation of a laboratory model....

  14. Arkansas Reference Sources. Bibliographic Series No. 26.

    Science.gov (United States)

    Ahrens, Joan; Roberts, Joan

    Varied sources for information on Arkansas held by the Arkansas University library are listed. Bibliographies and indexes of Arkansas publications are included, as well as materials dealing with the state's folklore and literature, arts and humanities, government and law, business and economics, social conditions, labor, history and biography,…

  15. Simple, high current, antimony ion source

    International Nuclear Information System (INIS)

    Sugiura, H.

    1979-01-01

    A simple metal ion source capable of producing a continuous, uncontaminated, high current beam of Sb ions is presented. It produced a total ion current of 200 μA at 1 kV extraction voltage. A discharge occurred in the source at a pressure of 6 x 10 -4 Torr. The ion current extracted from the source increased with the 3/2 power of the extraction voltage. The perveance of the source and ion density in the plasma were 8 x 10 -9 and 1.8 x 10 11 cm -3 , respectively

  16. Zotero : a free and open-source reference manager

    DEFF Research Database (Denmark)

    Courraud, Julie

    2014-01-01

    Zotero is a free, open-source reference management program compatible with Linux®, Mac®, and Windows® operating systems. Libraries are backed up online allowing sharing between computers and even multiple users. Zotero makes it easy to keep your reference library organised and ‘clean’. Reference...

  17. Inverse source problems for eddy current equations

    International Nuclear Information System (INIS)

    Rodríguez, Ana Alonso; Valli, Alberto; Camaño, Jessika

    2012-01-01

    We study the inverse source problem for the eddy current approximation of Maxwell equations. As for the full system of Maxwell equations, we show that a volume current source cannot be uniquely identified by knowledge of the tangential components of the electromagnetic fields on the boundary, and we characterize the space of non-radiating sources. On the other hand, we prove that the inverse source problem has a unique solution if the source is supported on the boundary of a subdomain or if it is the sum of a finite number of dipoles. We address the applicability of this result for the localization of brain activity from electroencephalography and magnetoencephalography measurements. (paper)

  18. Forget the Desk Job: Current Roles and Responsibilities in Entry-Level Reference Job Advertisements

    Science.gov (United States)

    Detmering, Robert; Sproles, Claudene

    2012-01-01

    This study examines the evolving roles and responsibilities of entry-level academic reference positions, as stated in recent job advertisements posted on the American Library Association's JobLIST Web site and other sources. Findings from a content analysis of these advertisements indicate that current entry-level reference positions in academic…

  19. Stability analysis of direct current control in current source rectifier

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Current source rectifier with high switching frequency has a great potential for improving the power efficiency and power density in ac-dc power conversion. This paper analyzes the stability of direct current control based on the time delay effect. Small signal model including dynamic behaviors...

  20. High current ion source development at Frankfurt

    Energy Technology Data Exchange (ETDEWEB)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M. [Frankfurt Univ. (Germany). Inst. fuer Angewandte Physik

    1995-11-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H{sup -}-sources each delivering a 70 mA H{sup -}-beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs.

  1. High current ion source development at Frankfurt

    International Nuclear Information System (INIS)

    Volk, K.; Klein, H.; Lakatos, A.; Maaser, A.; Weber, M.

    1995-01-01

    The development of high current positive and negative ion sources is an essential issue for the next generation of high current linear accelerators. Especially, the design of the European Spallation Source facility (ESS) and the International Fusion Material Irradiation Test Facility (IFMIF) have increased the significance of high brightness hydrogen and deuterium sources. As an example, for the ESS facility, two H - -sources each delivering a 70 mA H - -beam in 1.45 ms pulses at a repetition rate of 50 Hz are necessary. A low emittance is another important prerequisite. The source must operate, while meeting the performance requirements, with a constancy and reliability over an acceptable period of time. The present paper summarizes the progress achieved in ion sources development of intense, single charge, positive and negative ion beams. (author) 16 figs., 7 refs

  2. Programmable, very low noise current source

    Science.gov (United States)

    Scandurra, G.; Cannatà, G.; Giusi, G.; Ciofi, C.

    2014-12-01

    We propose a new approach for the realization of very low noise programmable current sources mainly intended for application in the field of low frequency noise measurements. The design is based on a low noise Junction Field Effect Transistor (JFET) acting as a high impedance current source and programmability is obtained by resorting to a low noise, programmable floating voltage source that allows to set the sourced current at the desired value. The floating voltage source is obtained by exploiting the properties of a standard photovoltaic MOSFET driver. Proper filtering and a control network employing super-capacitors allow to reduce the low frequency output noise to that due to the low noise JFET down to frequencies as low as 100 mHz while allowing, at the same time, to set the desired current by means of a standard DA converter with an accuracy better than 1%. A prototype of the system capable of supplying currents from a few hundreds of μA up to a few mA demonstrates the effectiveness of the approach we propose. When delivering a DC current of about 2 mA, the power spectral density of the current fluctuations at the output is found to be less than 25 pA/√Hz at 100 mHz and less than 6 pA/√Hz for f > 1 Hz, resulting in an RMS noise in the bandwidth from 0.1 to 10 Hz of less than 14 pA.

  3. Low Noise Bias Current/Voltage References Based on Floating-Gate MOS Transistors

    DEFF Research Database (Denmark)

    Igor, Mucha

    1997-01-01

    The exploitation of floating-gate MOS transistors as reference current and voltage sources is investigated. Test structures of common source and common drain floating-gate devices have been implemented in a commercially available 0.8 micron double-poly CMOS process. The measurements performed...

  4. Surface ionization ion source with high current

    International Nuclear Information System (INIS)

    Fang Jinqing; Lin Zhizhou; Yu Lihua; Zhan Rongan; Huang Guojun; Wu Jianhua

    1986-04-01

    The working principle and structure of a surface ionization ion source with high current is described systematically. Some technological keypoints of the ion source are given in more detail, mainly including: choosing and shaping of the material of the surface ionizer, heating of the ionizer, distributing of working vapour on the ionizer surface, the flow control, the cooling problem at the non-ionization surface and the ion optics, etc. This ion source has been used since 1972 in the electromagnetic isotope separator with 180 deg angle. It is suitable for separating isotopes of alkali metals and rare earth metals. For instance, in the case of separating Rubidium, the maximum ion current of Rbsup(+) extracted from the ion source is about 120 mA, the maximum ion current accepted by the receiver is about 66 mA, the average ion current is more than 25 mA. The results show that our ion source have advantages of high ion current, good characteristics of focusing ion beam, working stability and structure reliability etc. It may be extended to other fields. Finally, some interesting phenomena in the experiment are disccused briefly. Some problems which should be investigated are further pointed out

  5. Musicking Online: Organizing Reference Sources in the Digital Age

    Science.gov (United States)

    Szeto, Kimmy

    2012-01-01

    Online music research resources took center stage at the second plenary session "Wrangling the Information Universe: Moving From Institutional Portals to a Shared Resource for Online Music Sources" held on Friday, February 17, 2012, at the Music Library Association (MLA) 2012 Annual Meeting in Dallas, Texas. The Reference Sources…

  6. High Flux Isotope Reactor cold neutron source reference design concept

    International Nuclear Information System (INIS)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R.

    1998-05-01

    In February 1995, Oak Ridge National Laboratory's (ORNL's) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH 2 ) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH 2 cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept

  7. High Flux Isotope Reactor cold neutron source reference design concept

    Energy Technology Data Exchange (ETDEWEB)

    Selby, D.L.; Lucas, A.T.; Hyman, C.R. [and others

    1998-05-01

    In February 1995, Oak Ridge National Laboratory`s (ORNL`s) deputy director formed a group to examine the need for upgrades to the High Flux Isotope Reactor (HFIR) system in light of the cancellation of the Advanced neutron Source Project. One of the major findings of this study was that there was an immediate need for the installation of a cold neutron source facility in the HFIR complex. In May 1995, a team was formed to examine the feasibility of retrofitting a liquid hydrogen (LH{sub 2}) cold source facility into an existing HFIR beam tube. The results of this feasibility study indicated that the most practical location for such a cold source was the HB-4 beam tube. This location provides a potential flux environment higher than the Institut Laue-Langevin (ILL) vertical cold source and maximizes the space available for a future cold neutron guide hall expansion. It was determined that this cold neutron beam would be comparable, in cold neutron brightness, to the best facilities in the world, and a decision was made to complete a preconceptual design study with the intention of proceeding with an activity to install a working LH{sub 2} cold source in the HFIR HB-4 beam tube. During the development of the reference design the liquid hydrogen concept was changed to a supercritical hydrogen system for a number of reasons. This report documents the reference supercritical hydrogen design and its performance. The cold source project has been divided into four phases: (1) preconceptual, (2) conceptual design and testing, (3) detailed design and procurement, and (4) installation and operation. This report marks the conclusion of the conceptual design phase and establishes the baseline reference concept.

  8. Current Source Density Estimation for Single Neurons

    Directory of Open Access Journals (Sweden)

    Dorottya Cserpán

    2014-03-01

    Full Text Available Recent developments of multielectrode technology made it possible to measure the extracellular potential generated in the neural tissue with spatial precision on the order of tens of micrometers and on submillisecond time scale. Combining such measurements with imaging of single neurons within the studied tissue opens up new experimental possibilities for estimating distribution of current sources along a dendritic tree. In this work we show that if we are able to relate part of the recording of extracellular potential to a specific cell of known morphology we can estimate the spatiotemporal distribution of transmembrane currents along it. We present here an extension of the kernel CSD method (Potworowski et al., 2012 applicable in such case. We test it on several model neurons of progressively complicated morphologies from ball-and-stick to realistic, up to analysis of simulated neuron activity embedded in a substantial working network (Traub et al, 2005. We discuss the caveats and possibilities of this new approach.

  9. Cost Analysis Sources and Documents Data Base Reference Manual (Update)

    Science.gov (United States)

    1989-06-01

    M: Refcrence Manual PRICE H: Training Course Workbook 11. Use in Cost Analysis. Important source of cost estimates for electronic and mechanical...Nature of Data. Contains many microeconomic time series by month or quarter. 5. Level of Detail. Very detailed. 6. Normalization Processes Required...Reference Manual. Moorestown, N.J,: GE Corporation, September 1986. 64. PRICE Training Course Workbook . Moorestown, N.J.: GE Corporation, February 1986

  10. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    Energy Technology Data Exchange (ETDEWEB)

    Haffner, D.R.; Villelgas, A.J. [Pacific Northwest Lab., Richland, WA (United States)

    1996-01-01

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities.

  11. Technology, safety, and costs of decommissioning a reference large irradiator and reference sealed sources

    International Nuclear Information System (INIS)

    Haffner, D.R.; Villelgas, A.J.

    1996-01-01

    This report contains the results of a study sponsored by the US Nuclear Regulatory Commission (NRC) to examine the decommissioning of large radioactive irradiators and their respective facilities, and a broad spectrum of sealed radioactive sources and their respective devices. Conceptual decommissioning activities are identified, and the technology, safety, and costs (in early 1993 dollars) associated with decommissioning the reference large irradiator and sealed source facilities are evaluated. The study provides bases and background data for possible future NRC rulemaking regarding decommissioning, for evaluation of the reasonableness of planned decommissioning actions, and for determining if adequate funds are reserved by the licensees for decommissioning of their large irradiator or sealed source facilities. Another purpose of this study is to provide background and information to assist licensees in planning and carrying out the decommissioning of their sealed radioactive sources and respective facilities

  12. Reference volumetric samples of gamma-spectroscopic sources

    International Nuclear Information System (INIS)

    Taskaev, E.; Taskaeva, M.; Grigorov, T.

    1993-01-01

    The purpose of this investigation is to determine the requirements for matrices of reference volumetric radiation sources necessary for detector calibration. The first stage of this determination consists in analysing some available organic and nonorganic materials. Different sorts of food, grass, plastics, minerals and building materials have been considered, taking into account the various procedures of their processing (grinding, screening, homogenizing) and their properties (hygroscopy, storage life, resistance to oxidation during gamma sterilization). The procedures of source processing, sample preparation, matrix irradiation and homogenization have been determined. A rotation homogenizing device has been elaborated enabling to homogenize the matrix activity irrespective of the vessel geometry. 33 standard volumetric radioactive sources have been prepared: 14 - on organic matrix and 19 - on nonorganic matrix. (author)

  13. Anterior point of reference: Current knowledge and perspectives in prosthodontics

    Directory of Open Access Journals (Sweden)

    Prince Kumar

    2012-01-01

    Full Text Available The opening and closing mandibular axis is not a purely theoretical postulation, but an absolutely demonstrable biomechanical entity. It is very crucial to accurately record and transfer to articulators for the purpose of maxillofacial rehabilitation. Following the Face bow record and transfer of the mandibular axis to an anatomic articulator, we can then mount the casts so that they open and close on the articulator in the same fashion as the patient′s jaws. For this reason one of the fixed factors presented by the patient is taken into the consideration, which if properly considered, can be of inestimable value in all phases of dental treatment. This paper has sought to review the current concepts and practical implications regarding anterior point of reference in prosthodontics.

  14. Diode-Assisted Buck-Boost Current Source Inverters

    DEFF Research Database (Denmark)

    Gao, F.; Cai, Liang; Loh, P.C.

    2007-01-01

    This paper presents a couple of novel current source inverters (CSIs) with the enhanced current buckboost capability. With the unique diode-inductor network added between current source inverter circuitry and current boost elements, the proposed buck-boost current source inverters demonstrate...... uninfluenced. Lastly, all theoretical findings were verified experimentally using constructed laboratory prototypes....

  15. Reference sources for radionuclide calibrations in nuclear programmes

    International Nuclear Information System (INIS)

    Almeida, M.C.M. de; Delgado, J.U.; Poledna, R.; Silva, R.L. da; Oliveira, E.M. de; Di Prinzio, M.A.R.

    2009-01-01

    The radionuclide metrology laboratories aim to provide radioactive standards for detector calibrations in nuclear safety areas. To produce the reference sources to be furnished to users the following standards of 57 Co, 60 Co, 133 Ba, 241 Am, 152 Eu and 166 Ho are commonly used. In this work was made a verifying of the uncertainties obtained for the two methods: comparative (sample-standards) and efficiency curve. The total uncertainties obtained by sample-standard method varied from 0.4 to 1.2% (k = 1). The results using efficiency curve method to the same radioisotopes and same conditions are between 0.9 to 2.2% (k = 1). (author)

  16. Current status of digital reference services in academic libraries in ...

    African Journals Online (AJOL)

    This paper investigates the extent of the application of digital reference services in academic libraries in Nigeria, highlighting the emerging formats and models of digital reference services, to include email and web forms, Ask A librarian services, online chat reference, video conferencing, digital robots, and collaborative ...

  17. Development of Reference Source Terms for EU-APR1400

    Energy Technology Data Exchange (ETDEWEB)

    Kim, ByungIl; Lee, Chonghui; Lee, Dongsu; Ko, Heejin; Kang, Sangho [KEPCO Engineering and Construction Co. Inc., Yongin (Korea, Republic of)

    2014-05-15

    These source terms are developed for the typical U. S. NPP and do not reflect the design characteristics of EU-APR1400 (1,400 MWe PWR) which will be applied for the EUR certification in European countries. The process of developing the RST for EU-APR1400 is to undergo a similar process that NUREG-1465 had gone through when it came out with its proposed source terms. The purpose of this study is to develop the EU-APR1400 design-specific RST complied with the EUR. The Large LOCA is the reference equence used in the NUREG-1465 evaluation, whereas the EUAPR1400 risk-significant sequences are dominated by small LOCA and non-LOCA sequences. Moreover, when considering the EU-APR1400 has many design features to mitigate the consequences of severe accident phenomena, it is not surprising that the aspects of both release fractions and durations are distinctly different from NUREG-1465. This RST will be continuously updated to reflect to the design features of EU-APR1400, and then, be used as the reference for design purposes such as criteria satisfaction of radioactivity releases, equipment survivability, control room habitability for severe accident, and so on.

  18. High-Current Plasma Electron Sources

    International Nuclear Information System (INIS)

    Gushenets, J.Z.; Krokhmal, V.A.; Krasik, Ya. E.; Felsteiner, J.; Gushenets, V.

    2002-01-01

    In this report we present the design, electrical schemes and preliminary results of a test of 4 different electron plasma cathodes operating under Kg h-voltage pulses in a vacuum diode. The first plasma cathode consists of 6 azimuthally symmetrically distributed arc guns and a hollow anode having an output window covered by a metal grid. Plasma formation is initiated by a surface discharge over a ceramic washer placed between a W-made cathode and an intermediate electrode. Further plasma expansion leads to a redistribution of the discharge between the W-cathode and the hollow anode. An accelerating pulse applied between the output anode grid and the collector extracts electrons from this plasma. The operation of another plasma cathode design is based on Penning discharge for preliminary plasma formation. The main glow discharge occurs between an intermediate electrode of the Penning gun and the hollow anode. To keep the background pressure in the accelerating gap at P S 2.5x10 4 Torr either differential pumping or a pulsed gas puff valve were used. The operation of the latter electron plasma source is based on a hollow cathode discharge. To achieve a sharp pressure gradient between the cathode cavity and the accelerating gap a pulsed gas puff valve was used. A specially designed ferroelectric plasma cathode initiated plasma formation inside the hollow cathode. This type of the hollow cathode discharge ignition allowed to achieve a discharge current of 1.2 kA at a background pressure of 2x10 4 Torr. All these cathodes were developed and initially tested inside a planar diode with a background pressure S 2x10 4 Torr under the same conditions: accelerating voltage 180 - 300 kV, pulse duration 200 - 400 ns, electron beam current - 1 - 1.5 kA, and cross-sectional area of the extracted electron beam 113 cm 2

  19. Adaptive Sliding Mode Control of MEMS AC Voltage Reference Source

    Directory of Open Access Journals (Sweden)

    Ehsan Ranjbar

    2017-01-01

    Full Text Available The accuracy of physical parameters of a tunable MEMS capacitor, as the major part of MEMS AC voltage reference, is of great importance to achieve an accurate output voltage free of the malfunctioning noise and disturbance. Even though strenuous endeavors are made to fabricate MEMS tunable capacitors with desiderated accurate physical characteristics and ameliorate exactness of physical parameters’ values, parametric uncertainties ineluctably emerge in fabrication process attributable to imperfections in micromachining process. First off, this paper considers applying an adaptive sliding mode controller design in the MEMS AC voltage reference source so that it is capable of giving off a well-regulated output voltage in defiance of jumbling parametric uncertainties in the plant dynamics and also aggravating external disturbance imposed on the system. Secondly, it puts an investigatory comparison with the designed model reference adaptive controller and the pole-placement state feedback one into one’s prospective. Not only does the tuned adaptive sliding mode controller show remarkable robustness against slow parameter variation and external disturbance being compared to the pole-placement state feedback one, but also it immensely gets robust against the external disturbance in comparison with the conventional adaptive controller. The simulation results are promising.

  20. Magnesium-aerial primary current source

    Directory of Open Access Journals (Sweden)

    Barba I. N.

    2007-12-01

    Full Text Available Novel metal-air chemical power sources (CPS 3,0-ВМБ-7,5 have been developed. They have an unlimited shelf life and, even after decades of storage, give almost 100% of the designed capacity. These sources are water-activated. An aqueous salt solution is used as an electrolyte. Such sources are designed for single continuous or discontinuous discharge. The paper presents electrochemical reactions at the electrodes during CPS discharge. Comparison of electrical characteristics of the developed power source and various types of "dry cells" has shown that the developed sources have higher energy characteristics.

  1. Reference sources for radionuclide calibrations in nuclear programmes

    Energy Technology Data Exchange (ETDEWEB)

    Almeida, M.C.M. de; Delgado, J.U.; Poledna, R.; Silva, R.L. da; Oliveira, E.M. de; Di Prinzio, M.A.R., E-mail: marcandida@yahoo.com.b [Instituto de Radioprotecao e Dosimetria (IRD/CNEN-RJ), Rio de Janeiro, RJ (Brazil). Lab. Nacional de Metrologia das Radiacoes Ionizantes (LNMRI)

    2009-07-01

    The radionuclide metrology laboratories aim to provide radioactive standards for detector calibrations in nuclear safety areas. To produce the reference sources to be furnished to users the following standards of {sup 57}Co, {sup 60}Co, {sup 133}Ba, {sup 241}Am, {sup 152}Eu and {sup 166}Ho are commonly used. In this work was made a verifying of the uncertainties obtained for the two methods: comparative (sample-standards) and efficiency curve. The total uncertainties obtained by sample-standard method varied from 0.4 to 1.2% (k = 1). The results using efficiency curve method to the same radioisotopes and same conditions are between 0.9 to 2.2% (k = 1). (author)

  2. Tri-State Current Source Inverter With Improved Dynamic Performance

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Wong, Chow Pang

    2008-01-01

    Traditional dc-ac current source inverter (CSI) has a right-half-plane (RHP) zero in its control-to-output transfer function. This RHP zero causes the inverter output to fall before rising when a step increase in command reference is required (commonly known as non-minimum-phase effect). To achieve...... a better dynamic response, this paper proposes the design of a tri-state CSI using only an additional semiconductor switch for introducing unique freewheeling states to the traditional six active and three null states of a CSI. With the freewheeling states inserted appropriately within the inverter state...... sequence, the inductive boosting and discharging intervals can be decoupled, allowing the RHP zero to be eliminated with only minor circuit modifications (high level control schemes like predictive and multiloop voltage/current control remain unchanged). The designed inverter can be controlled using...

  3. Current Highlights on ESA's Planetary Technology Reference Studies

    Science.gov (United States)

    Falkner, P.

    The concept of Technology Reference Studies has been introduced already at EGU05, where the Venus Entry Probe (VEP), the Jupiter Minisat Explorer (JME), the Deimos Sample Return (DSR) and the Interstellar Heliopause Probe (IHP) have been presented in detail. At the EGU06 the new studies in reaction to the Cosmic Vision exercise have been introduced. The formulation of themes and mapping into potential future missions has been taken as basis in the planning of additional new and adaptation of existing TRS's to cover areas, which have not yet been addressed by any TRS. These new ongoing studies are progressing well and current highlights will be presented in the paper in further detail as well as an overview on supporting technology studies and Concurrent Design Facility (CDF) sessions. The Jupiter System Explorer (JSE) study investigates mission concepts with up to two Magnetospheric Orbiters placed in a highly elliptical Jovian orbit and the possibility to deploy a Jovian Entry Probe. The mission profile is based on a solar powered concept launched on a Soyuz-Fregat launcher. Mission analysis and the application of a new Jovian radiation model are supporting the study activities. The Near-Earth Asteroid Sample Return (NEA-SR) concept explores the possibilities of sample return or in-situ mission profiles with visits to up to two NEA targets. Due to the assumed low cost cap a trade between a sample return and remote/in-situ exploration concept has a high attention in the study. The Cross Scale TRS (CS-TRS) is intended to simultaneously investigate magnetospheric and plasma processes in three spatial scales with a formation flight of up to 12 spacecraft, orbiting on deep elliptical orbits around Earth. One of the major challenges is the launch of that number of spacecraft on a single launcher and the collisionless deployment of the formation at the target orbit. The scope if the GeoSail TRS is to demonstrate deployment, attitude control and navigation concepts for a

  4. The Supercontinuum Laser Source Fundamentals with Updated References

    CERN Document Server

    Alfano, Robert R

    2006-01-01

    Photonics and nonlinear optics are important areas of science, engineering and technology. One of the most important ultrafast nonlinear optical processes is the supercontinuum (SC) – the production of intense white light pulses covering: uv, visible, NIR, MIR, and IR. It is produced using ultrashort laser pulses (ps/fs) to produce the ultrabroad band of frequencies. This book covers the fundamental principles and surveys research of current thinkers and experts in the field with updated references of the key breakthroughs over the past decade and a half. The application of SC are time-resolved pump-SC probe absorption and excitation spectroscopy for chemistry, biology and physics fundamental processes; optical coherence tomography; ultrashort pulse generation in femtosecond and attosecond regions; frequency clocks; phase stabilization; optical communication; atmospheric science; lightning control; optical medical imaging; biological cell imaging; and metrology standards.

  5. Sources and performance criteria of uncertainty of reference measurement procedures.

    Science.gov (United States)

    Mosca, Andrea; Paleari, Renata

    2018-05-29

    This article wants to focus on the today available Reference Measurement Procedures (RMPs) for the determination of various analytes in Laboratory Medicine and the possible tools to evaluate their performance in the laboratories who are currently using them. A brief review on the RMPs has been performed by investigating the Joint Committee for Traceability in Laboratory Medicine (JCTLM) database. In order to evaluate their performances, we have checked the organization of three international ring trials, i.e. those regularly performed by the IFCC External Quality assessment scheme for Reference Laboratories in Laboratory Medicine (RELA), by the Center for Disease Control and Prevention (CDC) cholesterol network and by the IFCC Network for HbA 1c . Several RMPs are available through the JCTLM database, but the best way to collect information about the RMPs and their uncertainties is to look at the reference measurement service providers (RMS). This part of the database and the background on how to listed in the database is very helpful for the assessment of expanded uncertainty (MU) and performance in general of RMPs. Worldwide, 17 RMS are listed in the database, and for most of the measurands more than one RMS is able to run the relative RMPs, with similar expanded uncertainties. As an example, for a-amylase, 4 SP offer their services with MU between 1.6 and 3.3%. In other cases (such as total cholesterol, the U may span over a broader range, i.e. from 0.02 to 3.6%). With regard to the performance evaluation, the approach is often heterogenous, and it is difficult to compare the performance of laboratories running the same RMP for the same measurand if involved in more than one EQAS. The reference measurement services have been created to help laboratory professionals and manufacturers to implement the correct metrological traceability, and the JCTLM database is the only correct way to retrieve all the necessary important information to this end. Copyright © 2018

  6. Evaluation of the uniformity of wide circular reference source and application of correction factors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Sordi, G.A.A.; Potiens, M.P.A.

    2017-01-01

    In this work the uniformity of wide circular reference sources is evaluated. This kind of reference source is still widely used in Brazil. In previous works wide rectangular reference sources were analyzed and it was shown the importance of the application of correction factors in calibration procedures of radiation monitors. Now a transposition of the methods used formerly is performed, evaluating the uniformities of circular reference sources and calculating the associated correction factors. (author)

  7. Programmable current source for diode lasers stabilized optical fiber

    International Nuclear Information System (INIS)

    Gomez, J.; Camas, J.; Garcia, L.

    2012-01-01

    In this paper, we present the electronic design of a programmable stabilized current source. User can access to the source through a password, which, it has a database with the current and voltage operating points. This source was successfully used as current source in laser diode in optical fiber sensors. Variations in the laser current were carried out by a monitoring system and a control of the Direct Current (DC), which flowing through a How land source with amplifier. The laser current can be stabilized with an error percent of ± 1 μA from the threshold current (Ith) to its maximum operation current (Imax) in DC mode. The proposed design is reliable, cheap, and its output signal of stabilized current has high quality. (Author)

  8. A Modified Droop Control Method for Parallel-Connected Current Source Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    In this paper, a novel control method was proposed for current source inverters under the grid-connected working mode. The control scheme is based on a modified droop control method, with an additional current reference signal that will be generated instead of the voltage reference. Hence......, there is only a current control loop with droop control in the whole control scheme without voltage control loop. So it is very suitable for grid-connected current source inverter which will simplify the design of the control scheme and combine the advantage of droop control. The parallel configuration...... is widely used to acquire high power demand, but the circulating current problem is a key issue that should be considered. In this paper, a simulation based on parallel current source inverters using the proposed control scheme is provided. Simulation results showed that a good circulating current...

  9. Reference-Frame-Independent and Measurement-Device-Independent Quantum Key Distribution Using One Single Source

    Science.gov (United States)

    Li, Qian; Zhu, Changhua; Ma, Shuquan; Wei, Kejin; Pei, Changxing

    2018-04-01

    Measurement-device-independent quantum key distribution (MDI-QKD) is immune to all detector side-channel attacks. However, practical implementations of MDI-QKD, which require two-photon interferences from separated independent single-photon sources and a nontrivial reference alignment procedure, are still challenging with current technologies. Here, we propose a scheme that significantly reduces the experimental complexity of two-photon interferences and eliminates reference frame alignment by the combination of plug-and-play and reference frame independent MDI-QKD. Simulation results show that the secure communication distance can be up to 219 km in the finite-data case and the scheme has good potential for practical MDI-QKD systems.

  10. Reference materials for molecular diagnostics: Current achievements and future strategies.

    Science.gov (United States)

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  11. Simulation of wind wave growth with reference source functions

    Science.gov (United States)

    Badulin, Sergei I.; Zakharov, Vladimir E.; Pushkarev, Andrei N.

    2013-04-01

    We present results of extensive simulations of wind wave growth with the so-called reference source function in the right-hand side of the Hasselmann equation written as follows First, we use Webb's algorithm [8] for calculating the exact nonlinear transfer function Snl. Second, we consider a family of wind input functions in accordance with recent consideration [9] ( )s S = ?(k)N , ?(k) = ? ? ?- f (?). in k 0 ?0 in (2) Function fin(?) describes dependence on angle ?. Parameters in (2) are tunable and determine magnitude (parameters ?0, ?0) and wave growth rate s [9]. Exponent s plays a key role in this study being responsible for reference scenarios of wave growth: s = 4-3 gives linear growth of wave momentum, s = 2 - linear growth of wave energy and s = 8-3 - constant rate of wave action growth. Note, the values are close to ones of conventional parameterizations of wave growth rates (e.g. s = 1 for [7] and s = 2 for [5]). Dissipation function Sdiss is chosen as one providing the Phillips spectrum E(?) ~ ?5 at high frequency range [3] (parameter ?diss fixes a dissipation scale of wind waves) Sdiss = Cdissμ4w?N (k)θ(? - ?diss) (3) Here frequency-dependent wave steepness μ2w = E(?,?)?5-g2 makes this function to be heavily nonlinear and provides a remarkable property of stationary solutions at high frequencies: the dissipation coefficient Cdiss should keep certain value to provide the observed power-law tails close to the Phillips spectrum E(?) ~ ?-5. Our recent estimates [3] give Cdiss ? 2.0. The Hasselmann equation (1) with the new functions Sin, Sdiss (2,3) has a family of self-similar solutions of the same form as previously studied models [1,3,9] and proposes a solid basis for further theoretical and numerical study of wave evolution under action of all the physical mechanisms: wind input, wave dissipation and nonlinear transfer. Simulations of duration- and fetch-limited wind wave growth have been carried out within the above model setup to check its

  12. Identification of radioactive sources and devices. Reference manual

    International Nuclear Information System (INIS)

    2007-01-01

    This publication is intended to be a basic guide and not a comprehensive tool kit to identify and provide detailed emergency handling instructions for radioactive sources, devices and transport containers. In addition, this publication helps to identify sources and highlight the risks they present, and provides information on appropriate action. It is a small but significant step in the international community's continuing efforts to strengthen control of radioactive sources and nuclear material, increase safety and security, and thereby make the benefits of radioactive sources ever more broadly accessible. This publication was partly funded through the Nuclear Security Fund established under the Nuclear Security Plan

  13. Low noise constant current source for bias dependent noise measurements

    International Nuclear Information System (INIS)

    Talukdar, D.; Bose, Suvendu; Bardhan, K. K.; Chakraborty, R. K.

    2011-01-01

    A low noise constant current source used for measuring the 1/f noise in disordered systems in ohmic as well as nonohmic regime is described. The source can supply low noise constant current starting from as low as 1 μA to a few tens of milliampere with a high voltage compliance limit of around 20 V. The constant current source has several stages, which can work in a standalone manner or together to supply the desired value of load current. The noise contributed by the current source is very low in the entire current range. The fabrication of a low noise voltage preamplifier modified for bias dependent noise measurements and based on the existing design available in the MAT04 data sheet is also described.

  14. Numeric data services and sources for the general reference librarian

    CERN Document Server

    Kellam, Lynda

    2011-01-01

    The proliferation of online access to social science statistical and numeric data sources, such as the U.S. Census Bureau's American Fact Finder, has lead to an increased interest in supporting these sources in academic libraries. Many large libraries have been able to devote staff to data services for years, and recently smaller academic libraries have recognized the need to provide numeric data services and support. This guidebook serves as a primer to developing and supporting social science statistical and numerical data sources in the academic library. It provides strategies for the estab

  15. Sources of inspiration? Making sense of scientific references in patents

    NARCIS (Netherlands)

    Callaert, Julie; Pellens, Maikel; van Looy, Bart

    2013-01-01

    Scientific references in patent documents can be used as indicators signaling science-technology interactions. Whether they reflect a direct ‘knowledge flow’ from science to technology is subject of debate. Based on 33 interviews with inventors at Belgian firms and knowledge-generating institutes

  16. Shakespeare: A Student's Guide to Basic Reference Sources.

    Science.gov (United States)

    Claener, Anne, Comp.

    Basic and standard reference materials dealing with William Shakespeare are listed in this bibliography. Annotated entries are grouped under the following headings: concordances, dictionaries, encyclopedias and handbooks, and bibliographies. The section on bibliographies is further divided into lists of editions of Shakespeare's work, general…

  17. The Web as a Reference Tool: Comparisons with Traditional Sources.

    Science.gov (United States)

    Janes, Joseph; McClure, Charles R.

    1999-01-01

    This preliminary study suggests that the same level of timeliness and accuracy can be obtained for answers to reference questions using resources in freely available World Wide Web sites as with traditional print-based resources. Discusses implications for library collection development, new models of consortia, training needs, and costing and…

  18. 5 CFR 2502.4 - Public reference facilities and current index.

    Science.gov (United States)

    2010-01-01

    ... 5 Administrative Personnel 3 2010-01-01 2010-01-01 false Public reference facilities and current index. 2502.4 Section 2502.4 Administrative Personnel OFFICE OF ADMINISTRATION, EXECUTIVE OFFICE OF THE..., 5 U.S.C. 552 § 2502.4 Public reference facilities and current index. (a) The Office maintains a...

  19. Design and implementation of predictive filtering system for current reference generation of active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tomislav; Milun, Stanko; Petrovic, Goran [FESB University of Split, Faculty of Electrical Engineering, Machine Engineering and Naval Architecture, R. Boskovica bb, 21000, Split (Croatia)

    2007-02-15

    The shunt active power filters are used to attenuate the harmonic currents in power systems by injecting equal but opposite compensating currents. Successful control of the active filters requires an accurate current reference. In this paper the current reference determination based on predictive filtering structure is presented. Current reference was obtained by taking the difference of load current and its fundamental harmonic. For fundamental harmonic determination with no time delay a combination of digital predictive filter and low pass filter is used. The proposed method was implemented on a laboratory prototype of a three-phase active power filter. The algorithm for current reference determination was adapted and implemented on DSP controller. Simulation and experimental results show that the active power filter with implemented predictive filtering structure gives satisfactory performance in power system harmonic attenuation. (author)

  20. Experiences on current national income measures with reference to environmental and natural resources

    International Nuclear Information System (INIS)

    Franzese, R.; Gaudioso, D.

    1995-06-01

    The environment provides both a source of goods and services and a 'sink' for residues of the production and consumption processes. This is not reflected into conventional estimate of GDP (gross domestic product), the most commonly used measure of aggregate income. The purpose of this paper is to explore whether environmentally-adjusted national income measure can be derived. In the first part, the authors discuss both the shortcomings of the current national income measures, with reference to environmental and natural resources, and the debate on this issues; then they analyse the existing experiences to provide environmentally-adjusted indicators of national accounts. In the second part, the authors present an evaluation of the costs of environmental degradation in Italy in the period 1988-1990, based on the methodologies adopted in a pilot study carried out by UNSO (United Nations Statistical Office) and the World Bank for Mexico

  1. Process of magnetic reconnection as a source of longitudinal currents

    International Nuclear Information System (INIS)

    Sidneva, M.V.; Semenov, V.S.

    1987-01-01

    Variations in magnetic field and current system as applied to conditions in the Earth magnetospheric tail are calculated so as to show that three-dimensional reconnection leads inevitably to the appearance of a system of longitudinal currents. With reference to current layer of the magnetospheric tail the longitudinal currents appearing in the process of reconnection are directed to the Earth on the morning side and from Earth - on the evening side. The results presented suggest that magnetic reconnection can serve as a sourse of the Birkeland current loop of a substorm

  2. Timing reference generators and chopper controllers for neutron sources

    International Nuclear Information System (INIS)

    Nelson, R.; Merl, R.; Rose, C.

    2001-01-01

    Due to AC-power-grid frequency fluctuations, the designers for accelerator-based spallation-neutron facilities have worked to optimize the competing and contrasting demands of accelerator and neutron chopper performance. Powerful new simulation techniques have enabled the modeling of the timing systems that integrate chopper controllers and chopper hardware. For the first time, we are able to quantitatively access the tradeoffs between these two constraints and design or upgrade a facility to optimize total system performance. Thus, at LANSCE, we now operate multiple chopper systems and the accelerator as simple slaves to a single master-timing-reference generator. For the SNS we recommend a similar system that is somewhat less tightly coupled to the power grid. (author)

  3. The US EPA reference dose for methylmercury: sources of uncertainty

    International Nuclear Information System (INIS)

    Rice, D.C.

    2004-01-01

    The US Environmental Protection Agency (EPA) derived a reference dose for methylmercury in 2001, based on an extensive analysis by the National Research Council (NRC) of the National Academy of Sciences. The NRC performed benchmark dose analysis on a number of endpoints from three longitudinal prospective studies: the Seychelles Islands, the Faroe Islands, and the New Zealand studies. Adverse effects were reported in the latter two studies, but not in the Seychelles study. The NRC also performed an integrative analysis of all three studies. Dose conversion from cord blood or maternal hair mercury concentration was performed by EPA using a one-compartment pharmacokinetic model. A total uncertainty factor of 10 was applied for intrahuman pharmacokinetic and pharmacodynamic variability. There are numerous decisions made by the NRC/EPA that could greatly affect the value of the reference dose (RfD). Some of these include the choice of a linear model for the relationship between mercury body burden and neuropsychological performance, the choice of values of P 0 and the benchmark response, the use of the 'critical study/critical endpoint' approach in the interpretation of the maternal body burden that corresponds to the RfD, the use of central tendencies in a one-compartment pharmacokinetic model rather than the inclusion of the distributions of variables for the population of reproductive-age women, the assumption of unity for the ratio of fetal cord blood to maternal blood methylmercury concentrations, the choice of a total of 10 as an uncertainty factor, and the lack of dose-response analysis for other health effects such as cardiovascular disease. In addition, it may be argued that derivation of a RfD for methylmercury is inappropriate, given that there does not appear to be a threshold for adverse neuropsychological effects based on available data

  4. High current vacuum arc ion source for heavy ion fusion

    International Nuclear Information System (INIS)

    Qi, N.; Schein, J.; Gensler, S.; Prasad, R.R.; Krishnan, M.; Brown, I.

    1999-01-01

    Heavy Ion fusion (HIF) is one of the approaches for the controlled thermonuclear power production. A source of heavy ions with charge states 1+ to 2+, in ∼0.5 A current beams with ∼20 micros pulse widths and ∼10 Hz repetition rates are required. Thermionic sources have been the workhorse for the HIF program to date, but suffer from sloe turn-on, heating problems for large areas, are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states, in short and long pulse bursts, with low emittance and high beam currents. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications is investigated. An existing ion source at LBNL was modified to produce ∼0.5 A, ∼60 keV Gd (A∼158) ion beams. The experimental effort concentrated on beam noise reduction, pulse-to-pulse reproducibility and achieving low beam emittance at 0.5 A ion current level. Details of the source development will be reported

  5. SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KVp Electronic Brachytherapy Source

    International Nuclear Information System (INIS)

    Hiatt, JR; Rivard, MJ

    2014-01-01

    Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10 10 histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source

  6. Application Research of Horn Array Multi-Beam Antenna in Reference Source System for Satellite Interference Location

    Science.gov (United States)

    Zhou, Ping; Lin, Hui; Zhang, Qi

    2018-01-01

    The reference source system is a key factor to ensure the successful location of the satellite interference source. Currently, the traditional system used a mechanical rotating antenna which leaded to the disadvantages of slow rotation and high failure-rate, which seriously restricted the system’s positioning-timeliness and became its obvious weaknesses. In this paper, a multi-beam antenna scheme based on the horn array was proposed as a reference source for the satellite interference location, which was used as an alternative to the traditional reference source antenna. The new scheme has designed a small circularly polarized horn antenna as an element and proposed a multi-beamforming algorithm based on planar array. Moreover, the simulation analysis of horn antenna pattern, multi-beam forming algorithm and simulated satellite link cross-ambiguity calculation have been carried out respectively. Finally, cross-ambiguity calculation of the traditional reference source system has also been tested. The comparison between the results of computer simulation and the actual test results shows that the scheme is scientific and feasible, obviously superior to the traditional reference source system.

  7. High-current pulsed ion source for metallic ions

    International Nuclear Information System (INIS)

    Gavin, B.; Abbott, S.; MacGill, R.; Sorensen, R.; Staples, J.; Thatcher, R.

    1981-03-01

    A new sputter-ion PIG source and magnet system, optimized for intermediate charge states, q/A of 0.02 to 0.03, is described. This source will be used with the new Wideroe-based injector for the SuperHILAC. Pulsed electrical currents of several emA of heavy metal ions have been produced in a normalized emittance area of .05π cm-mr. The source system is comprised of two electrically separate anode chambers, one in operation and one spare, which can be selected by remote control. The entire source head is small and quickly removable

  8. Drive Current Enhancement in TFET by Dual Source Region

    Directory of Open Access Journals (Sweden)

    Zhi Jiang

    2015-01-01

    Full Text Available This paper presents tunneling field-effect transistor (TFET with dual source regions. It explores the physics of drive current enhancement. The novel approach of dual source provides an effective technique for enhancing the drive current. It is found that this structure can offer four tunneling junctions by increasing a source region. Meanwhile, the dual source structure does not influence the excellent features of threshold slope (SS of TFET. The number of the electrons and holes would be doubled by going through the tunneling junctions on the original basis. The overlap length of gate-source is also studied. The dependence of gate-drain capacitance Cgd and gate-source capacitance Cgs on gate-to-source voltage Vgs and drain-to-source voltage Vds was further investigated. There are simulation setups and methodology used for the dual source TFET (DS-TFET assessment, including delay time, total energy per operation, and energy-delay product. It is confirmed that the proposed TFET has strong potentials for VLSI.

  9. Five-Level Current-Source Inverters With Buck–Boost and Inductive-Current Balancing Capabilities

    DEFF Research Database (Denmark)

    Gao, Feng; Loh, Poh Chiang; Blaabjerg, Frede

    2010-01-01

    This paper presents new five-level current-source inverters (CSIs) with voltage/current buck–boost capability, unlike existing five-level CSIs where only voltage–boost operation is supported. The proposed inverters attain self-inductive-currentbalancing per switching cycle at their dc front ends...... without having to include additional balancing hardware or complex control manipulation. The inverters can conveniently be controlled by using the well-established phase-shifted carrier modulation scheme with only two additional linear references and a mapping logic table needed. Existing modulators can...

  10. Current control of PMSM based on maximum torque control reference frame

    Science.gov (United States)

    Ohnuma, Takumi

    2017-07-01

    This study presents a new method of current controls of PMSMs (Permanent Magnet Synchronous Motors) based on a maximum torque control reference frame, which is suitable for high-performance controls of the PMSMs. As the issues of environment and energy increase seriously, PMSMs, one of the AC motors, are becoming popular because of their high-efficiency and high-torque density in various applications, such as electric vehicles, trains, industrial machines, and home appliances. To use the PMSMs efficiently, a proper current control of the PMSMs is necessary. In general, a rotational coordinate system synchronizing with the rotor is used for the current control of PMSMs. In the rotating reference frame, the current control is easier because the currents on the rotating reference frame can be expressed as a direct current in the controller. On the other hand, the torque characteristics of PMSMs are non-linear and complex; the PMSMs are efficient and high-density though. Therefore, a complicated control system is required to involve the relation between the torque and the current, even though the rotating reference frame is adopted. The maximum torque control reference frame provides a simpler way to control efficiently the currents taking the torque characteristics of the PMSMs into consideration.

  11. Some high-current ion sources for materials modification

    International Nuclear Information System (INIS)

    Taylor, T.

    1989-01-01

    Ion sources for materials modification have evolved through three distinct generations. The first generation was adopted from research accelerators. These cold-cathode plasma-discharge devices generate beam currents of less than 100 μA. The hot-cathode plasma-discharge ion sources, originally developed for isotope separation, comprise the second generation. They produce between 100 μA and 10 mA of beam current. The third generation ion sources give beam currents in excess of 10 mA. This technology, transferred from industrial accelerators, has already made SIMOX (Separation by IMplanted OXygen) into a commercially viable semiconductor process and promises to do the same for ion implantation of metals and insulators. The author focuses on the third generation technology that will play a key role in the future of ion implantation. 10 refs.; 5 figs.; 2 tabs

  12. Performance evaluation of wideband bio-impedance spectroscopy using constant voltage source and constant current source

    International Nuclear Information System (INIS)

    Mohamadou, Youssoufa; Oh, Tong In; Wi, Hun; Sohal, Harsh; Farooq, Adnan; Woo, Eung Je; McEwan, Alistair Lee

    2012-01-01

    Current sources are widely used in bio-impedance spectroscopy (BIS) measurement systems to maximize current injection for increased signal to noise while keeping within medical safety specifications. High-performance current sources based on the Howland current pump with optimized impedance converters are able to minimize stray capacitance of the cables and setup. This approach is limited at high frequencies primarily due to the deteriorated output impedance of the constant current source when situated in a real measurement system. For this reason, voltage sources have been suggested, but they require a current sensing resistor, and the SNR reduces at low impedance loads due to the lower current required to maintain constant voltage. In this paper, we compare the performance of a current source-based BIS and a voltage source-based BIS, which use common components. The current source BIS is based on a Howland current pump and generalized impedance converters to maintain a high output impedance of more than 1 MΩ at 2 MHz. The voltage source BIS is based on voltage division between an internal current sensing resistor (R s ) and an external sample. To maintain high SNR, R s is varied so that the source voltage is divided more or less equally. In order to calibrate the systems, we measured the transfer function of the BIS systems with several known resistor and capacitor loads. From this we may estimate the resistance and capacitance of biological tissues using the least-squares method to minimize error between the measured transimpedance excluding the system transfer function and that from an impedance model. When tested on realistic loads including discrete resistors and capacitors, and saline and agar phantoms, the voltage source-based BIS system had a wider bandwidth of 10 Hz to 2.2 MHz with less than 1% deviation from the expected spectra compared to more than 10% with the current source. The voltage source also showed an SNR of at least 60 dB up to 2.2 MHz

  13. Cardiac magnetic source imaging based on current multipole model

    International Nuclear Information System (INIS)

    Tang Fa-Kuan; Wang Qian; Hua Ning; Lu Hong; Tang Xue-Zheng; Ma Ping

    2011-01-01

    It is widely accepted that the heart current source can be reduced into a current multipole. By adopting three linear inverse methods, the cardiac magnetic imaging is achieved in this article based on the current multipole model expanded to the first order terms. This magnetic imaging is realized in a reconstruction plane in the centre of human heart, where the current dipole array is employed to represent realistic cardiac current distribution. The current multipole as testing source generates magnetic fields in the measuring plane, serving as inputs of cardiac magnetic inverse problem. In the heart-torso model constructed by boundary element method, the current multipole magnetic field distribution is compared with that in the homogeneous infinite space, and also with the single current dipole magnetic field distribution. Then the minimum-norm least-squares (MNLS) method, the optimal weighted pseudoinverse method (OWPIM), and the optimal constrained linear inverse method (OCLIM) are selected as the algorithms for inverse computation based on current multipole model innovatively, and the imaging effects of these three inverse methods are compared. Besides, two reconstructing parameters, residual and mean residual, are also discussed, and their trends under MNLS, OWPIM and OCLIM each as a function of SNR are obtained and compared. (general)

  14. Characteristics of a high current ion source operated with lithium

    International Nuclear Information System (INIS)

    Bay, H.L.; Dullni, E.; Leismann, P.

    1986-05-01

    A low pressure arc ion source has been tested for operation with lithium. Currents up to 120 mA could be extracted through a multiple aperture extraction system at energies of 30 keV. The ion beam was neutralized up to 70% in a charge exchange cell filled with lithium vapour. The beam divergence ranged from 20 to 25 mrad full angle deduced from the spatial distribution of the collision induced Li I resonance line. Current densities from 2 to 3 mA/m 2 at a distance of 1.9 m from the source were measured either by laser induced fluorescence or with a Faraday cup. (orig.)

  15. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  16. Pulsed negative hydrogen source for currents up to one ampere

    International Nuclear Information System (INIS)

    Prelec, K.; Sluyters, T.

    1975-01-01

    During the 2nd Symposium on Ion Sources and Formation of Ion Beams, the development of a Mk II pulsed double slit magnetron source for the production of negative hydrogen ions was discussed. The source was capable of yielding beam currents up to 125 milliamperes, corresponding to current densities of 1.25 A/cm 2 . In order to increase negative hydrogen beam intensities by an order of magnitude (this would be quite useful for initial high energy neutral injector systems on Tokamaks), a larger, Mk III magnetron has been constructed, with the number of slits increased up to six. The idea was to utilize in a more efficient way the plasma width. In addition, such a source geometry will be more adaptable for beam formation and acceleration than single slit structures. With three extraction slits, a negative hydrogen yield of 300 mA was obtained with current densities of 1.2 A/cm 2 ; preliminary results with six extraction slits showed beam currents in excess of half an ampere with averaged current densities in excess of 0.75 A/cm 2 . (U.S.)

  17. Current-type flipped-Γ-source inverters

    DEFF Research Database (Denmark)

    Loh, Poh Chiang; Li, Ding; Blaabjerg, Frede

    2012-01-01

    are of interest since they use lesser components. Their winding turns might however become too excessive for higher demanded gains. Avoiding this usual trend, a new family of current-type flipped-Γ-source inverters are proposed, whose common gain is raised by lowering, and not increasing, the winding turns...

  18. Evaluation of a new 10 mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Power, F

    2002-01-01

    A new DC current reference standard has been developed as a component in a Current calibration hierarchy in the LHC project at CERN. The standard provides 10 mA DC current with an accuracy less than 0.5 ppm, drift less than 2 ppm/year and compliance error less than 0.1 ppm for 0-10 V. The paper gives the results from two years evaluation of a series of 5 units.

  19. Laser Lights or Dim Bulbs? Evaluating Reference Librarians' Use of Electronic Sources.

    Science.gov (United States)

    Welch, Jeanie M.

    1999-01-01

    Discusses the evaluation of academic library reference librarians' effectiveness in providing services to patrons using electronic sources based on experiences at the University of North Carolina at Charlotte. Topics include core technical competencies for subject specialists and reference desk service; the Internet; and methods of evaluation.…

  20. Evaluation of the homogeneity of reference flat sources used in calibration of surface contamination monitors

    International Nuclear Information System (INIS)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Potiens, M.P.A.

    2014-01-01

    The aim of this study was to re-evaluate the uniformity of the wide area reference sources of the Calibration Laboratory of Instruments (LCI-IPEN) used in the calibration of surface contamination monitors, according the recommendations of the ISO 8769 standard and the NRPB. In this work used six wide area reference sources of 150 cm 2 of 241 Am, 14 C, 36 Cl, 137 Cs, 90 Sr+ 90 Y and 99 Tc with reference dates between 1996 and 1997 and three sources of 100 cm 2 of 14 C, 137 Cs and 60 Co were used with reference dates 2007. Measurements were performed with a radiation monitor of the Thermo, model FH40GX with a pancake probe, model FHZ732GM. We also made several models on paper with the objective of define each measurement position and an aluminum plate with a square hole (6.25 cm 2 ) in its center, allowing the passage of the radiation only through the hole. Each wide area reference source was positioned in setup and measurements were performed in order to cover the entire surface of the source. The values of the uniformity obtained partially confirm previous data obtained in another study conducted by LCI-IPEN, showing that some wide area reference sources 150 cm 2 in disagree with ISO 8769. In the former work, just the source of 241 Am (7.3%) was within the range specified by the standard, now have sources of 241 Am (5.7%), 137 Cs (8.8%), 90 Sr+ 9 '0Y (8, 8%) and 99 Tc (9.2%) with values within the specified uniformity. The sources of 14 C (53.3%) and 36 Cl (16.6%) were outside the specified. The wide area reference sources of 100 cm 2 , show disagreement in values of uniformity of the sources 14 C (46.7%) and 60 Co (10.4%). The values of the uniformity of the wide area reference sources show that some fonts can not be used in calibrations, because not in accordance with the value of uniformity specified in ISO 8769:2010, this is a conditions to believe a laboratory according to ISO 17025, show the laboratory performs its services with a high quality. The

  1. Reference values of fractional excretion of exhaled nitric oxide among non-smokers and current smokers.

    Science.gov (United States)

    Torén, Kjell; Murgia, Nicola; Schiöler, Linus; Bake, Björn; Olin, Anna-Carin

    2017-08-25

    Fractional exhaled nitric oxide (FE NO ) is used to assess of airway inflammation; diagnose asthma and monitor adherence to advised therapy. Reliable and accurate reference values for FE NO are needed for both non-smoking and current smoking adults in the clinical setting. The present study was performed to establish reference adult FE NO values among never-smokers, former smokers and current smokers. FE NO was measured in 5265 subjects aged 25-75 years in a general-population study, using a chemiluminescence (Niox ™) analyser according to the guidelines of the American Thoracic Society and the European Respiratory Society. Atopy was based on the presence of immunoglobulin E (IgE) antibodies to common inhalant allergens (measured using Phadiatop® test). Spirometry without bronchodilation was performed and forced vital capacity (FVC), forced expired volume in 1 s (FEV 1 ) and the ratio of FEV 1 to FVC values were obtained. After excluding subjects with asthma, chronic bronchitis, spirometric airway obstruction and current cold, 3378 subjects remained. Equations for predictions of FE NO values were modelled using nonparametric regression models. FE NO levels were similar in never-smokers and former smokers, and these two groups were therefore merged into a group termed "non-smokers". Reference equations, including the 5th and 95th percentiles, were generated for female and male non-smokers, based on age, height and atopy. Regression models for current smokers were unstable. Hence, the proposed reference values for current smokers are based on the univariate distribution of FE NO and fixed cut-off limits. Reference values for FE NO among respiratory healthy non-smokers should be outlined stratified for gender using individual reference values. For current smokers separate cut-off limits are proposed.

  2. Efficient Location of Research Reference Sources in the Field of Dance.

    Science.gov (United States)

    Kissinger, Pat; Jay, Danielle

    More than 45 basic dance reference research sources that would be useful to students, scholars, teachers, historians, and therapists are discussed in this bibliographic essay. Aspects of dance covered include choreography, criticism, teaching principles, aesthetic theory, dance therapy, and history. Sources are grouped by type: dictionaries and…

  3. 78 FR 21008 - Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference...

    Science.gov (United States)

    2013-04-08

    ... products) for calendar year 2012. DATES: The 2012 inflation adjustment factor, nonconventional source fuel... DEPARTMENT OF THE TREASURY Internal Revenue Service Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference Price for Calendar Year 2012 AGENCY: Internal Revenue Service...

  4. 76 FR 19524 - Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference...

    Science.gov (United States)

    2011-04-07

    ... products) for calendar year 2010. DATES: The 2010 inflation adjustment factor, nonconventional source fuel... DEPARTMENT OF THE TREASURY Internal Revenue Service Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference Price for Calendar Year 2010 AGENCY: Internal Revenue Service...

  5. 77 FR 22067 - Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference...

    Science.gov (United States)

    2012-04-12

    ... calendar year 2011. DATES: The 2011 inflation adjustment factor and nonconventional source fuel credit... DEPARTMENT OF THE TREASURY Internal Revenue Service Publication of Inflation Adjustment Factor, Nonconventional Source Fuel Credit, and Reference Price for Calendar Year 2011 AGENCY: Internal Revenue Service...

  6. Passivity enhancement by series LC filtered active damper with zero current reference

    DEFF Research Database (Denmark)

    Bai, Haofeng; Wang, Xiongfei; Blaabjerg, Frede

    2016-01-01

    can be improved by enhancing the passivity of the total admittance seen by the grid, which allows for a zero current reference and a much simpler current controller for the active damper. To show the performance of the active damper with zero reference, this paper first carries out the impedance based...... stability analysis of grid converters in the weak grid. Based on the impedance model of the series LC filtered active damper, the real part of its output admittance is investigated and shown to be able to enhance the passivity of the admittance of the converters seen by the grid. Finally, simulation...

  7. New digital reference current generation for shunt active power filter under distorted voltage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Abdusalam, Mohamed; Karimi, Shahram; Saadate, Shahrokh [Groupe de Recherche en Electrotechnique et Electronique de Nancy (GREEN), CNRS UMR 7037 (France); Poure, Philippe [Laboratoire d' Instrumentation Electronique de Nancy (LIEN), EA 3440, Universite Henri Poincare - Nancy Universite, B.P. 239, 54506 Vandoeuvre les Nancy Cedex (France)

    2009-05-15

    In this paper, a new reference current computation method suitable for shunt active power filter control under distorted voltage conditions is proposed. The active power filter control is based on the use of self-tuning filters (STF) for the reference current generation and on a modulated hysteresis current controller. This active filter is intended for harmonic compensation of a diode rectifier feeding a RL load under distorted voltage conditions. The study of the active filter control is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents and is experimentally implemented in a DS1104 card of a DSPACE prototyping system. The second part focuses on the generation of the switching pattern of the inverter by using a modulated hysteresis current controller, implemented in an analogue card. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the {alpha}-{beta} axis without phase locked loop (PLL). The performances are good even under distorted voltage conditions. First, the effectiveness of the new proposed method is mathematically studied and verified by computer simulation. Then, experimental results are presented using a DSPACE system associated with the analogue current controller for a real shunt active power filter. (author)

  8. Design and evaluation of a 10-mA DC current reference standard

    CERN Document Server

    Fernqvist, G; Pickering, J; Power, F

    2003-01-01

    A new DC current reference standard has been developed for high- current power converter calibration in the large hadron collider (LHC) project at the European Organization for Nuclear Research (CERN). This standard provides a near ideal 10-mA DC current with long-term drift of one part in 10/sup 6/ per year. The paper describes the requirements and the detailed design and evaluation of the unit. Since similar 10-V standards are commercially available, the paper concentrates on the unique current output capability of this device. (4 refs).

  9. Optical Spectra of Candidate International Celestial Reference Frame (ICRF) Flat-spectrum Radio Sources. III

    Energy Technology Data Exchange (ETDEWEB)

    Titov, O.; Stanford, Laura M. [Geoscience Australia, P.O. Box 378, Canberra, ACT 2601 (Australia); Pursimo, T. [Nordic Optical Telescope, Nordic Optical Telescope Apartado 474E-38700 Santa Cruz de La Palma, Santa Cruz de Tenerife (Spain); Johnston, Helen M.; Hunstead, Richard W. [Sydney Institute for Astronomy, School of Physics, University of Sydney, NSW 2006 (Australia); Jauncey, David L. [CSIRO Astronomy and Space Science, ATNF and Mount Stromlo Observatory, Cotter Road, Weston, ACT 2611 (Australia); Zenere, Katrina A., E-mail: oleg.titov@ga.gov.au [School of Physics, University of Sydney, NSW 2006 (Australia)

    2017-04-01

    In extending our spectroscopic program, which targets sources drawn from the International Celestial Reference Frame (ICRF) Catalog, we have obtained spectra for ∼160 compact, flat-spectrum radio sources and determined redshifts for 112 quasars and radio galaxies. A further 14 sources with featureless spectra have been classified as BL Lac objects. Spectra were obtained at three telescopes: the 3.58 m European Southern Observatory New Technology Telescope, and the two 8.2 m Gemini telescopes in Hawaii and Chile. While most of the sources are powerful quasars, a significant fraction of radio galaxies is also included from the list of non-defining ICRF radio sources.

  10. Development of high current low energy H+ ion source

    International Nuclear Information System (INIS)

    Forrester, A.T.; Crow, J.T.; Goebel, D.M.

    1978-01-01

    The ultimate goal of this work is the development of an ion source suitable for double charge exchange of D + ions to D - ions in cesium or other vapor. Since the fraction of the D + which changes to D - may be as high as 0.35 in the energy below one keV, the process appears very favorable. What is desired is a source of several hundred cm 2 area, with a D + current density greater than, say 0.2A/cm 2 . Small angular spread is essential with up to about 0.1 radian being acceptable. A simple approach to this problem appears to be through fine mesh extraction electrodes. In this system a single grid facing the ion source plasma constitutes the entire extraction electrode system. If the potential difference between the grid and the source plasma is large compared to the ion energy at the plasma boundary, then the distance s 0 is just the Child-Langmuir distance corresponding to the ion current density J and the potential difference V 0 between the plasma and the grid

  11. Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    . In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters......, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating...

  12. Applying inversion techniques to derive source currents and geoelectric fields for geomagnetically induced current calculations

    Directory of Open Access Journals (Sweden)

    J. S. de Villiers

    2014-10-01

    Full Text Available This research focuses on the inversion of geomagnetic variation field measurement to obtain source currents in the ionosphere. During a geomagnetic disturbance, the ionospheric currents create magnetic field variations that induce geoelectric fields, which drive geomagnetically induced currents (GIC in power systems. These GIC may disturb the operation of power systems and cause damage to grounded power transformers. The geoelectric fields at any location of interest can be determined from the source currents in the ionosphere through a solution of the forward problem. Line currents running east–west along given surface position are postulated to exist at a certain height above the Earth's surface. This physical arrangement results in the fields on the ground having the magnetic north and down components, and the electric east component. Ionospheric currents are modelled by inverting Fourier integrals (over the wavenumber of elementary geomagnetic fields using the Levenberg–Marquardt technique. The output parameters of the inversion model are the current strength, height and surface position of the ionospheric current system. A ground conductivity structure with five layers from Quebec, Canada, based on the Layered-Earth model is used to obtain the complex skin depth at a given angular frequency. This paper presents preliminary and inversion results based on these structures and simulated geomagnetic fields. The results show some interesting features in the frequency domain. Model parameters obtained through inversion are within 2% of simulated values. This technique has applications for modelling the currents of electrojets at the equator and auroral regions, as well as currents in the magnetosphere.

  13. DC feedback for wide band frequency fixed current source

    Directory of Open Access Journals (Sweden)

    Aoday Hashim Mohamad Al-Rawi

    2013-03-01

    Full Text Available Alternating current sources are mainly used in bioelectrical impedance devices. Nowadays 50 – 100 kHz bioelectrical impedance devices are commonly used for body composition analysis. High frequency bioelectrical impedance analysis devices are mostly used in bioimpedance tomography and blood analysis. High speed op-amps and voltage comparators are used in this circuit. Direct current feedback is used to prevent delay. An N-Channel J-FET transistor was used to establish the voltage controlled gain amplifier (VCG. A sine wave signal has been applied as input voltage. The value of this signal should be constant in 170 mV rms to keep the output current in about 1 mA rms. Four frequencies; 100 kHz, 1 MHz, 2 MHz and 3.2 MHz were applied to the circuit and the current was measured for different load resistances. The results showed that the current was stable for changes in the resistor load, bouncing around an average point as a result of bouncing DC feedback.

  14. Renewable energy sources in Bulgaria: Current state and trends

    Science.gov (United States)

    Kolev, K.

    The over-dependency of Bulgaria on imported fuel stressed the importance of developing a new energy strategy based on energy saving which includes also using renewable energy sources (RES). The target is the substitution of at least 2 percent of the real primary energy consumption with RES by 2010. The author gives a generalized analysis of the available RES in Bulgaria -solar, wind, geothermal, biomass and mini-hydraulic. The potentialities of each source for its usage as a suitable energy supply are pointed out, as well as the current status of research and implementation work, problems connected with legislation, financing and production of particular facilities. The governmental policy concerning RES is considered briefly. A description is given to the project 'Technical and Economical Assessment of Possibilities for Expansion of the RES-part in the Energy Balance of the Country' developed and started in 1994 in the framework of the PHARE program.

  15. High-current negative-ion sources for pulsed spallation neutron sources: LBNL workshop, October 1994

    International Nuclear Information System (INIS)

    Alonso, J.R.

    1995-09-01

    The neutron scattering community has endorsed the need for a high-power (1 to 5 MW) accelerator-driven source of neutrons for materials research. Properly configured, the accelerator could produce very short (sub-microsecond) bursts of cold neutrons, said time structure offering advantages over the continuous flux from a reactor. The recent cancellation of the ANS reactor project has increased the urgency to develop a comprehensive strategy based on the best technological scenarios. Studies to date have built on the experience from ISIS (the 160 kW source in the UK), and call for a high-current (approx. 100 mA peak) H- source-linac combination injecting into one or more accumulator rings in which beam may be further accelerated. The I to 5 GeV proton beam is extracted in a single turn and brought to the target-moderator stations. The high current, high duty-factor, high brightness and high reliability required of the ion source present a very large challenge to the ion source community. The Workshop reported on here, held in Berkeley in October 1994, analyzed in detail the source requirements for proposed accelerator scenarios, the present performance capabilities of different H- source technologies, and identified necessary R ampersand D efforts to bridge the gap

  16. Accelerator driven neutron sources in Korea. Current and future

    International Nuclear Information System (INIS)

    Lee, Young-Ouk; Oh, Byung-Hoon; Hong, Bong-Geun; Chang, Jonghwa; Chang, Moon-Hee; Kim, Guinyun; Kim, Gi-Donng; Choi, Byung-Ho

    2008-01-01

    The Pohang Neutron Facility, based on a 65 MeV electron linear accelerator, has a neutron-gamma separation circuit, water-moderated tantalum target and 12 m TOF. It produces pulsed photonuclear neutrons with ≅2 μs width, 50 mA peak current and 15 Hz repetition, mainly for the neutron nuclear data production in up to keV energies. The Tandem Van de Graff at Korea Institute of Geoscience and Mineral Resources (KIGAM) is dedicated to measure MeV energy neutron capture and total cross section using TOF and prompt gamma ray detection system. The facility pulsed ≅10 8 mono-energetic neutrons/sec from 3 H(p,n) reaction with 1-2 ns width and 125 ns period. Korea Institute of Radiological and Medical Sciences (KIRAMS) has the MC50 medical cyclotron which accelerates protons up to an energy of 45 MeV and has several beam ports for proton or neutron irradiations. Beam current can be controlled from a few nano amperes to 50 uA. Korea Atomic Energy Research Institute (KAERI) has a plan to develop a neutron source by using 20 MeV electron accelerator. This photo-neutron source will be mainly used for nuclear data measurements based on time-of-flight experiments. A high intensity fast neutron source is also proposed to respond growing demands of fast neutrons, especially for the fusion material test. Throughput will be as high as several 10 13 neutrons/sec from D-T reaction powered by a high current (200 mA) ion source, a drive-in target and cooling systems, and closed circuit tritium ventilation/recovery systems. The Proton Engineering Frontier Project (PEFP) is developing a 100 MeV, 20 mA pulsed proton linear accelerator equipped with 5 target rooms, one of which is dedicated to produce neutrons using tungsten target. PEFP also proposes the 1-2 GeV rapid cycling synchrotron accelerator as an extension of the PEFP linac, which can be used for nuclear and high energy physics experiment, spallation neutron source, radioisotope, medical research, etc. (author)

  17. Lithium current sources with an electrolyte based on aprotonic solvents

    Energy Technology Data Exchange (ETDEWEB)

    Shembel, Ye.M.; Ksenzhek, O.S.; Litvinova, V.I.; Martynenko, T.L.; Raykhelson, L.B.; Sokolov, L.A.; Strizhko, A.S.

    1984-01-01

    Lithium current sources with an electrolyte based on aprotonic solvents are examined. The effect of the composition of the electrolyte solution on the solubility of SO2 and the excess pressure of the gas above the electrolyte solution is established. The temperature characteristics of the electrolyte are studied from the standpoint of salt solubility, the association between the discharge conditions, the macrostructure of the porous inert cathode and the degree of usage of the active cathode substance of the SO2 as the necessary aspects for solving the problems of optimizing a lithium and SO2 system.

  18. Electric machine and current source inverter drive system

    Science.gov (United States)

    Hsu, John S

    2014-06-24

    A drive system includes an electric machine and a current source inverter (CSI). This integration of an electric machine and an inverter uses the machine's field excitation coil for not only flux generation in the machine but also for the CSI inductor. This integration of the two technologies, namely the U machine motor and the CSI, opens a new chapter for the component function integration instead of the traditional integration by simply placing separate machine and inverter components in the same housing. Elimination of the CSI inductor adds to the CSI volumetric reduction of the capacitors and the elimination of PMs for the motor further improve the drive system cost, weight, and volume.

  19. A 6.13MeV gamma reference source, measurement of the emission rate

    International Nuclear Information System (INIS)

    Robert, Andre; Blondel, Maurice; Morel, Jean; Thomas, Claude.

    1977-08-01

    A 6.13MeV γ reference source has been produced by using 13 C(α, nγ) 16 O reaction occurring in an intimate 13 C and 238 Pu mixture. With two walls made leak proof this standard source is easy handled and convenient to the calibration of detectors. The 6.13MeV gamma ray is emitted without Doeppler effect, is measured with an uncertainty of 6% by three independent methods [fr

  20. Measurement of the depth of narrow slotted sections in eddy current reference standards

    Science.gov (United States)

    Kim, Young-Joo; Kim, Young-gil; Ahn, Bongyoung; Yoon, Dong-Jin

    2007-02-01

    The dimensions of the slots in eddy current (EC) reference standards are too narrow to be measured by general depth measurement methods such as the optical (laser) or stylus methods. However, measurement of the dimensions of the machined slots is a prerequisite to using the blocks as references. The present paper suggests a measurement method for the slotted section using an ultrasonic test. The width and depth of the slots measured in our study are roughly 0.1 mm and 0.5 mm, respectively. The time of flight (TOF) of the ultrasonic wave was measured precisely. The ultrasonic velocity in the material of the EC reference standard was calculated with the measured values of the TOF and its thickness. Reflected waves from the tip of the slot and the bottom surface of the EC standard were successfully classified. Using this method we have successfully determined the depth of the slotted section.

  1. High current DC negative ion source for cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Etoh, H., E-mail: Hrh-Etoh@shi.co.jp; Aoki, Y.; Mitsubori, H.; Arakawa, Y.; Sakuraba, J.; Kato, T.; Mitsumoto, T.; Hiasa, T.; Yajima, S. [Sumitomo Heavy Industries, Ltd., Tokyo 141-6025 (Japan); Onai, M.; Hatayama, A. [Graduate School of Science and Technology, Keio University, Kanagawa 223-8522 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Ibaraki 305-0801 (Japan); Okumura, Y. [Fusion Research and Development Directorate, Japan Atomic Energy Agency, Aomori 039-3212 (Japan)

    2016-02-15

    A filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In Cs-free operation, continuous H{sup −} beam of 10 mA and D{sup −} beam of 3.3 mA were obtained stably at an arc-discharge power of 3 kW and 2.4 kW, respectively. In Cs-seeded operation, H{sup −} beam current reached 22 mA at a lower arc power of 2.6 kW with less co-extracted electron current. The optimum gas flow rate, which gives the highest H{sup −} current, was 15 sccm in the Cs-free operation, while it decreased to 4 sccm in the Cs-seeded operation. The relationship between H{sup −} production and the design/operating parameters has been also investigated by a numerical study with KEIO-MARC code, which gives a reasonable explanation to the experimental results of the H{sup −} current dependence on the arc power.

  2. A high-current pulsed cathodic vacuum arc plasma source

    International Nuclear Information System (INIS)

    Oates, T.W.H.; Pigott, J.; Mckenzie, D.R.; Bilek, M.M.M.

    2003-01-01

    Cathodic vacuum arcs (CVAs) are well established as a method for producing metal plasmas for thin film deposition and as a source of metal ions. Fundamental differences exist between direct current (dc) and pulsed CVAs. We present here results of our investigations into the design and construction of a high-current center-triggered pulsed CVA. Power supply design based on electrolytic capacitors is discussed and optimized based on obtaining the most effective utilization of the cathode material. Anode configuration is also discussed with respect to the optimization of the electron collection capability. Type I and II cathode spots are observed and discussed with respect to cathode surface contamination. An unfiltered deposition rate of 1.7 nm per pulse, at a distance of 100 mm from the source, has been demonstrated. Instantaneous plasma densities in excess of 1x10 19 m -3 are observed after magnetic filtering. Time averaged densities an order of magnitude greater than common dc arc densities have been demonstrated, limited by pulse repetition rate and filter efficiency

  3. A simple and effective method to achieve the successful start-up of a current reference

    International Nuclear Information System (INIS)

    Han Lei; Zhang Xiaoxing; Dai Yujie; Lü Yingjie; Wang Yujun

    2012-01-01

    Start-up design is a critical issue in current reference as it is very closely related to production yield. However, its function is difficult to predict using normal transaction simulations before the device is put into diffusion. In this paper, we discuss a simple and effective simulation approach which ensures a successful start-up process in a self-biased temperature independent current reference. The circuit is implemented in a class-D power amplifier with a 0.35 μm BiCMOS process and the experimental result validates that, by using this method, the start-up success rate can be greatly improved to 100%. (semiconductor integrated circuits)

  4. A ns-pulsed high-current electron beam source

    International Nuclear Information System (INIS)

    Guan, Gexin; Li, Youzhi; Pan, Yuli

    1988-01-01

    The behaviour of a pulse electron beam source which is composed of a gun and pulse system depends on not only the time characteristics of the gun and the pulser, but also their combination. This point become apparent if effects of the electron tansit-time between electrodes are studied. A ferrite transmission line (FTL) pulser is used as a grid driver in this source. It has advantages of providing fast risetime, large peak power output and good loading characteristics. It is these advantages of the pulser that compensates the absence of some technological conditions of manufacturing gun and makes the source better. Our testing showed that the cooperation of both the gun and the pulser produced peak currents in the range of 1 to 9 amps with widths of 2 to 2.5 ns (FWHM) at cathode-to-anode potential of 60 to 82 kv, while the grid drives are about in the range of 1 to 3 kv. In addition, the results of the testing instructed that effects of electron transit-time cannot be ignored when the pulses with widths of several nanoseconds are used as a grid drive. Based on the results, electron transit-time effects on the design of the gun and the beam performances are briefly descussed in this paper. (author)

  5. Design and construction of constant voltage and current regulated source with proper characteristics to be used in electronics laboratory designs

    International Nuclear Information System (INIS)

    Peon A, R.

    1978-01-01

    A regulated direct current feeding source was designed for the Nuclear Energy National Institute Electronics Labortory, with the following characteristics: a) voltage input 105-130V a.c. 50-60 Hz; b) voltage output 0.40 V d.c.; c) output current 0-2 Amp d.c.; d) load regulation 0.001%; e) line regulation 0.001%; f) ripple and noise 200 μ Vpp; g) temperature interval 3-60 0 C; h) stability 0.5%; i) output impedance as voltage source 0.01 ohms; j) transient response 50 μ seg. Besides of operating normally, that is as voltage source or current-source through the front controls, the source can be used and interconnected with one or other compatible sources (autoseries, autoparallel and programmed reference). The source will cost 70,000 pesos approximately. (author)

  6. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    Energy Technology Data Exchange (ETDEWEB)

    Burns, R.E. Jr.; O`Brien, J.M. Jr. [Atlan-Tech, Rosewll, GA (United States)

    1993-12-31

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison.

  7. Factors affecting quality for beta dose rate measurements using ISO 6980 series I reference sources

    International Nuclear Information System (INIS)

    Burns, R.E. Jr.; O'Brien, J.M. Jr.

    1993-01-01

    Atlan-Tech, Inc. has performed several calibrations of ISO 6980 Series 1 reference beta sources over the past two to three years. There were many problems encountered in attempting to compare the results of these calibrations with those from other laboratories, indicating the need for more standardization in the methodology employed for the measurement of the absorbed dose rate from ISO 6980 Series 1 reference beta sources. This document describes some of the problems encountered in attempting to intercompare results of beta dose-rate measurements. It proposes some solutions in an attempt to open a dialogue among facilities using reference beta standards for the purpose of promoting better measurement quality assurance through data intercomparison

  8. Thermoelectric properties of currently available Au/Pt thermocouples related to the valid reference function

    Directory of Open Access Journals (Sweden)

    Edler F.

    2015-01-01

    Full Text Available Au/Pt thermocouples are considered to be an alternative to High Temperature Standard Platinum Resistance Thermometers (HTSPRTs for realizing temperatures according to the International Temperature Scale of 1990 (ITS-90 in the temperature range between aluminium (660.323 °C and silver (961.78 °C. The original aim of this work was to develop and to validate a new reference function for Au/Pt thermocouples which reflects the properties of presently commercially available Au and Pt wires. The thermoelectric properties of 16 Au/Pt thermocouples constructed at different National Metrological Institutes by using wires from different suppliers and 4 commercially available Au/Pt thermocouples were investigated. Most of them exhibit significant deviations from the current reference function of Au/Pt thermocouples caused by the poor performance of the Au-wires available. Thermoelectric homogeneity was investigated by measuring immersion profiles during freezes at the freezing point of silver and in liquid baths. The thermoelectric inhomogeneities were found to be one order of magnitude larger than those of Au/Pt thermocouples of the Standard Reference Material® (SRM® 1749. The improvement of the annealing procedure of the gold wires is a key process to achieve thermoelectric homogeneities in the order of only about (2–3 mK, sufficient to replace the impracticable HTSPRTs as interpolation instruments of the ITS-90. Comparison measurements of some of the Au/Pt thermocouples against a HTSPRT and an absolutely calibrated radiation thermometer were performed and exhibit agreements within the expanded measurement uncertainties. It has been found that the current reference function of Au/Pt thermocouples reflects adequately the thermoelectric properties of currently available Au/Pt thermocouples.

  9. PV source based high voltage gain current fed converter

    Science.gov (United States)

    Saha, Soumya; Poddar, Sahityika; Chimonyo, Kudzai B.; Arunkumar, G.; Elangovan, D.

    2017-11-01

    This work involves designing and simulation of a PV source based high voltage gain, current fed converter. It deals with an isolated DC-DC converter which utilizes boost converter topology. The proposed converter is capable of high voltage gain and above all have very high efficiency levels as proved by the simulation results. The project intends to produce an output of 800 V dc from a 48 V dc input. The simulation results obtained from PSIM application interface were used to analyze the performance of the proposed converter. Transformer used in the circuit steps up the voltage as well as to provide electrical isolation between the low voltage and high voltage side. Since the converter involves high switching frequency of 100 kHz, ultrafast recovery diodes are employed in the circuitry. The major application of the project is for future modeling of solar powered electric hybrid cars.

  10. Current sources of carbon tetrachloride (CCl4) in our atmosphere

    Science.gov (United States)

    Sherry, David; McCulloch, Archie; Liang, Qing; Reimann, Stefan; Newman, Paul A.

    2018-02-01

    Carbon tetrachloride (CCl4 or CTC) is an ozone-depleting substance whose emissive uses are controlled and practically banned by the Montreal Protocol (MP). Nevertheless, previous work estimated ongoing emissions of 35 Gg year-1 of CCl4 into the atmosphere from observation-based methods, in stark contrast to emissions estimates of 3 (0-8) Gg year-1 from reported numbers to UNEP under the MP. Here we combine information on sources from industrial production processes and legacy emissions from contaminated sites to provide an updated bottom-up estimate on current CTC global emissions of 15-25 Gg year-1. We now propose 13 Gg year-1 of global emissions from unreported non-feedstock emissions from chloromethane and perchloroethylene plants as the most significant CCl4 source. Additionally, 2 Gg year-1 are estimated as fugitive emissions from the usage of CTC as feedstock and possibly up to 10 Gg year-1 from legacy emissions and chlor-alkali plants.

  11. A stationary reference frame current control for a multi-level H-bridge power converter for universal and flexible power management in future electricity network

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Iov, Florin; Zanchetta, Pericle

    2008-01-01

    converters for grid connection of renewable sources will be needed. These power converters must be able to provide intelligent power management as well as ancillary services. This paper assesses a control method based on the stationary reference frame with Proportional-Resonant current controllers...

  12. Alternative current source based Schottky contact with additional electric field

    Science.gov (United States)

    Mamedov, R. K.; Aslanova, A. R.

    2017-07-01

    Additional electric field (AEF) in the Schottky contacts (SC) that covered the peripheral contact region wide and the complete contact region narrow (as TMBS diode) SC. Under the influence of AEF is a redistribution of free electrons produced at certain temperatures of the semiconductor, and is formed the space charge region (SCR). As a result of the superposition of the electric fields SCR and AEF occurs the resulting electric field (REF). The REF is distributed along a straight line perpendicular to the contact surface, so that its intensity (and potential) has a minimum value on the metal surface and the maximum value at a great distance from the metal surface deep into the SCR. Under the influence of AEF as a sided force the metal becomes negative pole and semiconductor - positive pole, therefore, SC with AEF becomes an alternative current source (ACS). The Ni-nSi SC with different diameters (20-1000 μm) under the influence of the AEF as sided force have become ACS with electromotive force in the order of 0.1-1.0 mV, which are generated the electric current in the range of 10-9-10-7 A, flowing through the external resistance 1000 Ohm.

  13. OPTICAL SPECTRA OF CANDIDATE INTERNATIONAL CELESTIAL REFERENCE FRAME (ICRF) FLAT-SPECTRUM RADIO SOURCES

    Energy Technology Data Exchange (ETDEWEB)

    Titov, O.; Stanford, Laura M. [Geoscience Australia, P.O. Box 378, Canberra, ACT 2601 (Australia); Johnston, Helen M.; Hunstead, Richard W. [Sydney Institute for Astronomy, School of Physics, University of Sydney, NSW 2006 (Australia); Pursimo, T. [Nordic Optical Telescope, Nordic Optical Telescope Apartado 474E-38700 Santa Cruz de La Palma, Santa Cruz de Tenerife (Spain); Jauncey, David L. [CSIRO Astronomy and Space Science, ATNF and Research School of Astronomy and Astrophysics, Australian National University, Canberra, ACT 2611 (Australia); Maslennikov, K. [Central Astronomical Observatory at Pulkovo, Pulkovskoye Shosse, 65/1, 196140, St. Petersburg (Russian Federation); Boldycheva, A., E-mail: oleg.titov@ga.gov.au [Ioffe Physical Technical Institute, 26 Polytekhnicheskaya, St. Petersburg, 194021 (Russian Federation)

    2013-07-01

    Continuing our program of spectroscopic observations of International Celestial Reference Frame (ICRF) sources, we present redshifts for 120 quasars and radio galaxies. Data were obtained with five telescopes: the 3.58 m European Southern Observatory New Technology Telescope, the two 8.2 m Gemini telescopes, the 2.5 m Nordic Optical Telescope (NOT), and the 6.0 m Big Azimuthal Telescope of the Special Astrophysical Observatory in Russia. The targets were selected from the International VLBI Service for Geodesy and Astrometry candidate International Celestial Reference Catalog which forms part of an observational very long baseline interferometry (VLBI) program to strengthen the celestial reference frame. We obtained spectra of the potential optical counterparts of more than 150 compact flat-spectrum radio sources, and measured redshifts of 120 emission-line objects, together with 19 BL Lac objects. These identifications add significantly to the precise radio-optical frame tie to be undertaken by Gaia, due to be launched in 2013, and to the existing data available for analyzing source proper motions over the celestial sphere. We show that the distribution of redshifts for ICRF sources is consistent with the much larger sample drawn from Faint Images of the Radio Sky at Twenty cm (FIRST) and Sloan Digital Sky Survey, implying that the ultra-compact VLBI sources are not distinguished from the overall radio-loud quasar population. In addition, we obtained NOT spectra for five radio sources from the FIRST and NRAO VLA Sky Survey catalogs, selected on the basis of their red colors, which yielded three quasars with z > 4.

  14. Comparison between two methodologies for uniformity correction of extensive reference sources

    International Nuclear Information System (INIS)

    Junior, Iremar Alves S.; Siqueira, Paulo de T.D.; Vivolo, Vitor; Potiens, Maria da Penha A.; Nascimento, Eduardo

    2016-01-01

    This article presents the procedures to obtain the uniformity correction factors for extensive reference sources proposed by two different methodologies. The first methodology is presented by the Good Practice Guide of Nº 14 of the NPL, which provides a numerical correction. The second one uses the radiation transport code, MCNP5, to obtain the correction factor. Both methods retrieve very similar corrections factor values, with a maximum deviation of 0.24%. (author)

  15. Comparison of the Equine Reference Sequence with Its Sanger Source Data and New Illumina Reads.

    Directory of Open Access Journals (Sweden)

    Jovan Rebolledo-Mendez

    Full Text Available The reference assembly for the domestic horse, EquCab2, published in 2009, was built using approximately 30 million Sanger reads from a Thoroughbred mare named Twilight. Contiguity in the assembly was facilitated using nearly 315 thousand BAC end sequences from Twilight's half brother Bravo. Since then, it has served as the foundation for many genome-wide analyses that include not only the modern horse, but ancient horses and other equid species as well. As data mapped to this reference has accumulated, consistent variation between mapped datasets and the reference, in terms of regions with no read coverage, single nucleotide variants, and small insertions/deletions have become apparent. In many cases, it is not clear whether these differences are the result of true sequence variation between the research subjects' and Twilight's genome or due to errors in the reference. EquCab2 is regarded as "The Twilight Assembly." The objective of this study was to identify inconsistencies between the EquCab2 assembly and the source Twilight Sanger data used to build it. To that end, the original Sanger and BAC end reads have been mapped back to this equine reference and assessed with the addition of approximately 40X coverage of new Illumina Paired-End sequence data. The resulting mapped datasets identify those regions with low Sanger read coverage, as well as variation in genomic content that is not consistent with either the original Twilight Sanger data or the new genomic sequence data generated from Twilight on the Illumina platform. As the haploid EquCab2 reference assembly was created using Sanger reads derived largely from a single individual, the vast majority of variation detected in a mapped dataset comprised of those same Sanger reads should be heterozygous. In contrast, homozygous variations would represent either errors in the reference or contributions from Bravo's BAC end sequences. Our analysis identifies 720,843 homozygous discrepancies

  16. Current state of renewable energies performances in the European Union: A new reference framework

    International Nuclear Information System (INIS)

    D’Adamo, Idiano; Rosa, Paolo

    2016-01-01

    Highlights: • A common mathematic model, based on historical values, defines future trends. • Luxembourg, Ireland and Netherlands do not reach their 2020 national targets. • The selected indexes significantly influences the ranking of European countries. • Sweden, Finland, Austria and Latvia have a dominant position. • Ten countries have a value greater than the EU 28 average for each index analysed. - Abstract: Initially pushed by the European Union (EU) through the Europe 2020 strategy, the development of renewable energies is a strategic action aiming to limit climate changes and cut greenhouse gas emissions. National subsidies favored the diffusion of this new kind of energy sources, even if there are interesting economic opportunities also in non-subsidized markets. Renewable energy (RE) is a sustainable choice, but its management requires a proper analysis, both from political and operational levels. The aim of this paper is the assessment of European renewable energy source (RES) trajectory towards 2020, starting from historical values and through common scientific methods. In addition, a new reference framework is proposed, in order to evaluate RESs performances in Europe. The framework is based on three indicators: (i) share of energy from RESs in gross final energy consumption, (ii) REs primary production per capita and (iii) gross final consumption of REs per capita. Results could have practical implications for the decision makers involved in the management of energy sources throughout Europe and could be used for the comparison on a global scale.

  17. A high current, short pulse electron source for wakefield accelerators

    International Nuclear Information System (INIS)

    Ho, Ching-Hung.

    1992-01-01

    Design studies for the generation of a high current, short pulse electron source for the Argonne Wakefield Accelerator are presented. An L-band laser photocathode rf gun cavity is designed using the computer code URMEL to maximize the electric field on the cathode surface for fixed frequency and rf input power. A new technique using a curved incoming laser wavefront to minimize the space charge effect near the photocathode is studied. A preaccelerator with large iris to minimize wakefield effects is used to boost the drive beam to a useful energy of around 20 MeV for wakefield acceleration experiments. Focusing in the photocathode gun and the preaccelerator is accomplished with solenoids. Beam dynamics simulations throughout the preaccelerator are performed using particle simulation codes TBCI-SF and PARMELA. An example providing a useful set of operation parameters for the Argonne Wakefield Accelerator is given. The effects of the sagitta of the curved beam and laser amplitude and timing jitter effects are discussed. Measurement results of low rf power level bench tests and a high power test for the gun cavity are presented and discussed

  18. Evaluation of Skin Surface as an Alternative Source of Reference DNA Samples: A Pilot Study.

    Science.gov (United States)

    Albujja, Mohammed H; Bin Dukhyil, Abdul Aziz; Chaudhary, Abdul Rauf; Kassab, Ahmed Ch; Refaat, Ahmed M; Babu, Saranya Ramesh; Okla, Mohammad K; Kumar, Sachil

    2018-01-01

    An acceptable area for collecting DNA reference sample is a part of the forensic DNA analysis development. The aim of this study was to evaluate skin surface cells (SSC) as an alternate source of reference DNA sample. From each volunteer (n = 10), six samples from skin surface areas (forearm and fingertips) and two traditional samples (blood and buccal cells) were collected. Genomic DNA was extracted and quantified then genotyped using standard techniques. The highest DNA concentration of SSC samples was collected using the tape/forearm method of collection (2.1 ng/μL). Cotton swabs moistened with ethanol yielded higher quantities of DNA than swabs moistened with salicylic acid, and it gave the highest percentage of full STR profiles (97%). This study supports the use of SSC as a noninvasive sampling technique and as a extremely useful source of DNA reference samples among certain cultures where the use of buccal swabs can be considered socially unacceptable. © 2017 American Academy of Forensic Sciences.

  19. SU-E-T-284: Revisiting Reference Dosimetry for the Model S700 Axxent 50 KV{sub p} Electronic Brachytherapy Source

    Energy Technology Data Exchange (ETDEWEB)

    Hiatt, JR [Rhode Island Hospital, Providence, RI (United States); Rivard, MJ [Tufts University School of Medicine, Boston, MA (United States)

    2014-06-01

    Purpose: The model S700 Axxent electronic brachytherapy source by Xoft was characterized in 2006 by Rivard et al. The source design was modified in 2006 to include a plastic centering insert at the source tip to more accurately position the anode. The objectives of the current study were to establish an accurate Monte Carlo source model for simulation purposes, to dosimetrically characterize the new source and obtain its TG-43 brachytherapy dosimetry parameters, and to determine dose differences between the source with and without the centering insert. Methods: Design information from dissected sources and vendor-supplied CAD drawings were used to devise the source model for radiation transport simulations of dose distributions in a water phantom. Collision kerma was estimated as a function of radial distance, r, and polar angle, θ, for determination of reference TG-43 dosimetry parameters. Simulations were run for 10{sup 10} histories, resulting in statistical uncertainties on the transverse plane of 0.03% at r=1 cm and 0.08% at r=10 cm. Results: The dose rate distribution the transverse plane did not change beyond 2% between the 2006 model and the current study. While differences exceeding 15% were observed near the source distal tip, these diminished to within 2% for r>1.5 cm. Differences exceeding a factor of two were observed near θ=150° and in contact with the source, but diminished to within 20% at r=10 cm. Conclusions: Changes in source design influenced the overall dose rate and distribution by more than 2% over a third of the available solid angle external from the source. For clinical applications using balloons or applicators with tissue located within 5 cm from the source, dose differences exceeding 2% were observed only for θ>110°. This study carefully examined the current source geometry and presents a modern reference TG-43 dosimetry dataset for the model S700 source.

  20. A Circulating Current Suppression Method for Parallel Connected Voltage-Source-Inverters (VSI) with Common DC and AC Buses

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    This paper describes a theoretical with experiment study on a control strategy for the parallel operation of threephase voltage source inverters (VSI), to be applied to uninterruptible power systems (UPS). A circulating current suppression strategy for parallel VSIs is proposed in this paper based...... on circulating current control loops used to modify the reference currents by compensating the error currents among parallel inverters. Both of the cross and zero-sequence circulating currents are considered. The proposed method is coordinated together with droop and virtual impedance control. In this paper......, droop control is used to generate the reference voltage of each inverter, and the virtual impedance is used to fix the output impedance of the inverters. In addition, a secondary control is used in order to recover the voltage deviation caused by the virtual impedance. And the auxiliary current control...

  1. Sealed radionuclide sources - new technical specifications and current practice

    Energy Technology Data Exchange (ETDEWEB)

    Brabec, D

    1987-03-01

    Basic technical specifications are discussed valid in Czechoslovakia for sealed radionuclide sources, based on international ISO and CMEA standards. Described are the standardization of terminology, relationships of tests, testing methods, types of sealed sources and their applications, relations to Czechoslovak regulations on radiation protection and to IAEA specifications for radioactive material shipment, etc. Practical impact is shown of the introduction of the new standards governing sealed sources on the national economy, and the purpose is explained of various documents issued with sealed sources. (author). 2 figs., 45 refs.

  2. Inverter for Interchangeable Use as Current Source Inverter and Voltage Source Inverter for Interconnecting to Grid

    Science.gov (United States)

    Teruya, Daisuke; Masukawa, Shigeo; Iida, Shoji

    We propose a novel inverter that can be operated either as a Current Source Inverter (CSI) or as a Voltage Source Inverter (VSI) by changing only the control signals. It is proper to apply it to the interconnecting system with renewal energy, such as photovoltaic cells or wind generation systems, to a grid. This inverter is usually operated as the CSI connected to the grid. Even if the energy source has a lower voltage than the grid, the energy can be supplied to the grid through the proposed inverter. The power factor can be briefly maintained at almost unity. When power supply from the grid is interrupted, the proposed circuit should be operated as the VSI in the stand-alone operation mode. In this way, the circuit can maintain a constant output voltage to the loads. In this paper, the proposed circuit configuration and the control schemes for both the CSI and the VSI are described. Further, the circuit characteristics for both are discussed experimentally.

  3. Matrix pencil method-based reference current generation for shunt active power filters

    DEFF Research Database (Denmark)

    Terriche, Yacine; Golestan, Saeed; Guerrero, Josep M.

    2018-01-01

    response and works well under distorted and unbalanced voltage. Moreover, the proposed method can estimate the voltage phase accurately; this property enables the algorithm to compensate for both power factor and current unbalance. The effectiveness of the proposed method is verified using simulation...... are using the discrete Fourier transform (DFT) in the frequency domain or the instantaneous p–q theory and the synchronous reference frame in the time domain. The DFT, however, suffers from the picket-fence effect and spectral leakage. On the other hand, the DFT takes at least one cycle of the nominal...... frequency. The time-domain methods show a weakness under voltage distortion, which requires prior filtering techniques. The aim of this study is to present a fast yet effective method for generating the RCC for SAPFs. The proposed method, which is based on the matrix pencil method, has a fast dynamic...

  4. Fourier transform holography with extended references using a coherent ultra-broadband light source.

    Science.gov (United States)

    Tenner, Vasco T; Eikema, Kjeld S E; Witte, Stefan

    2014-10-20

    We demonstrate a technique that enables lensless holographic imaging with extended reference structures, using ultra-broadband radiation sources for illumination. We show that this 'two-pulse imaging' approach works with one- and two-dimensional HERALDO reference structures, and demonstrate that the obtained spectrally resolved data can be used to improve the signal-to-noise ratio in the final image. Intensity stitching of multiple exposures is applied to increase the detected dynamic range, leading to an improved image reconstruction. Furthermore, we show that a combination of holography and iterative phase retrieval can be used to obtain high-quality images quickly and reliably, by using the HERALDO reconstruction as the initial support constraint in the iterative phase retrieval algorithm. A signal-to-noise improvement of two orders of magnitude is achieved compared to the basic HERALDO result.

  5. Current-voltage model of LED light sources

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Munk-Nielsen, Stig

    2012-01-01

    Amplitude modulation is rarely used for dimming light-emitting diodes in polychromatic luminaires due to big color shifts caused by varying magnitude of LED driving current and nonlinear relationship between intensity of a diode and driving current. Current-voltage empirical model of light...

  6. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    International Nuclear Information System (INIS)

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda

    2013-01-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m 3 of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m 3 of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both a local

  7. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda [Australian Nuclear Science and Technology Organisation, Kirrawee DC (Australia)

    2013-07-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m{sup 3} of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m{sup 3} of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both

  8. Current schemes for National Synchrotron Light Source UV beamlines

    International Nuclear Information System (INIS)

    Williams, G.P.; Howells, M.R.; McKinney, W.R.

    1979-01-01

    We describe in some detail four beamlines proposed for the National Synchrotron Light Source uv ring at Brookhaven National Laboratory. Three grazing-incidence instruments, one of the plane grating Mijake type and two with toroidal gratings at grazing angles of 2-1/2 0 and 15 0 are described. Two normal incidence instruments, one using the source as entrance slit and accepting 75 milliradians horizontally are also discussed. In each case we have estimated the output fluxes expected from such beamlines

  9. DEPRECIATION AS THE SOURCE OF REPLENISHMENT OF ENTERPRISE CURRENT ASSETS

    Directory of Open Access Journals (Sweden)

    KAFKA Sofiіa

    2017-06-01

    Full Text Available Along with the classical approach to understanding the meaning of such economic category as depreciation, we have considered the issues if the amortization is the source of the fixed assets renewal. For the purposes of the study we used methods of analysis and synthesis, systematic approach - to study the processes of working capital enterprises, logical method and simulation - to systematize information security of these processes. Results of investigations to determine the characteristics of the economic substance of depreciation established: depreciation is a compensation of working capital, which at one time was removed from circulation for the purchase of fixed assets, so you cannot treat depreciation as a source of investment in fixed assets. The source of the formation of the working capital of own funds is certainly profits and depreciation - only if profitable economic activity. So when it comes to sources of funding something, including the acquisition (creation of fixed assets, only the working capital can be the source that’s why it is important to use them efficiently and the conditions of the limited resources. The practical significance is to develop scientifically based recommendations on formation and sources of working capital enterprises and reproduction of fixed assets, which provide methodological support to forming the depreciation policy of enterprises

  10. Application of optical emission spectroscopy to high current proton sources

    International Nuclear Information System (INIS)

    Castro, G; Mazzaglia, M; Nicolosi, D; Mascali, D; Reitano, R; Celona, L; Leonardi, O; Leone, F; Naselli, E; Neri, L; Torrisi, G; Gammino, S; Zaniol, B

    2017-01-01

    Optical Emission Spectroscopy (OES) represents a very reliable technique to carry out non-invasive measurements of plasma density and plasma temperature in the range of tens of eV. With respect to other diagnostics, it also can characterize the different populations of neutrals and ionized particles constituting the plasma. At INFN-LNS, OES techniques have been developed and applied to characterize the plasma generated by the Flexible Plasma Trap, an ion source used as 'testbench' of the proton source built for European Spallation Source. This work presents the characterization of the parameters of a hydrogen plasma in different conditions of neutral pressure, microwave power and magnetic field profile, along with perspectives for further upgrades of the OES diagnostics system. (paper)

  11. National greenhouse gas accounts: Current anthropogenic sources and sinks

    International Nuclear Information System (INIS)

    Subak, S.; Raskin, P.; Hippel, David von

    1992-01-01

    This study provides spatially disaggregated estimates of greenhouse gas emissions from the major anthropogenic sources for 145 countries. The data compilation is comprehensive in approach, including emissions from CO, CH 4 , N 2 O and ten halocarbons, in addition to CO 2 . The sources include emissions from fossil fuel production and use, cement production, halocarbons, landfills, land use changes, biomass burning, rice and livestock production and fertilizer consumption. The approach used to derive these estimates corresponds closely with the simple methodologies proposed by the Greenhouse Gas Emissions Task Force of the Intergovernmental Panel on Climate Change. The inventory includes a new estimate of greenhouse gas emissions from fossil fuel combustion based principally on data from the International Energy Agency. The research methodologies for estimating emissions from all sources is briefly described and compared with other recent studies in the literature. (112 refs.)

  12. Electrode cooling for long pulse high current ion sources

    International Nuclear Information System (INIS)

    McKenzie-Wilson, R.B.

    1979-01-01

    The need for cooling of electrode surface in ion sources for neutral beam line applications is summarized. The properties of possible cooling fluids are discussed and the decision to use water as a cooling fluid of choice is explained. The influence of source geometry on the design of a cooling canal is examined and two possible designs are presented. The need for model testing and the results of the tests on a model cathode are also discussed. Some remarks are also made on a method of predicting burnout failure of a cooled electrode

  13. Current status of CHESS - the Cornell High Energy Synchrotron Source

    International Nuclear Information System (INIS)

    Mills, D.; Cornell Univ., Ithaca, NY

    1982-01-01

    This paper reviews the status of CHESS through its three-year construction period, which ends in the fall of 1981. Included are a brief description of beam lines, monochromators, station instrumentations and support facilities. Our experiences with source size and stability over the last year are reported, along with planned fall revisions and running schedule. (orig.)

  14. Pulsed high-current electron source: Final report

    International Nuclear Information System (INIS)

    Spindt, C.A.

    1988-10-01

    The objective of this investigation was to investigate ways to realize the cathode's potential as a source for high power pulse operation. The questions that needed to be studied were those of large area coverage, maximum emission that the cathode arrays are capable of producing practically, uniformity of emission over large areas, and the ability to operate with high voltage anodes. 9 figs

  15. Hydrogen from renewable sources. Current and future constraints

    International Nuclear Information System (INIS)

    Falchetta, M.; Galli, S.

    2001-01-01

    Using renewable energy sources to produce hydrogen as an energy vector could assure a fully sustainable renewable energy system with zero emissions. Many conversion technologies (in particular water electrolysis) are already available and proven, but are still far from being economically competitive [it

  16. Current status of ground-source heat pumps in China

    International Nuclear Information System (INIS)

    Yang Wei; Zhou Jin; Xu Wei; Zhang Guoqiang

    2010-01-01

    As a renewable energy technology, the ground-source heat pump (GSHP) technologies have increasingly attracted world-wide attention due to their advantages of energy efficiency and environmental friendliness. This paper presents Chinese research and application on GSHP followed by descriptions of patents. The policies related to GSHP are also introduced and analyzed. With the support of Chinese government, several new heat transfer models and two new GSHP systems (named pumping and recharging well (PRW) and integrated soil cold storage and ground-source heat pump (ISCS and GSHP) system) have been developed by Chinese researchers. The applications of GSHP systems have been growing rapidly since the beginning of the 21st century with financial incentives and supportive government policies. However, there are still several challenges for the application of GSHP systems in large scale. This paper raises relevant suggestions for overcoming the existing and potential obstacles. In addition, the developing and applying prospects of GSHP systems in China are also discussed.

  17. DEPRECIATION AS THE SOURCE OF REPLENISHMENT OF ENTERPRISE CURRENT ASSETS

    OpenAIRE

    KAFKA Sofiіa

    2017-01-01

    Along with the classical approach to understanding the meaning of such economic category as depreciation, we have considered the issues if the amortization is the source of the fixed assets renewal. For the purposes of the study we used methods of analysis and synthesis, systematic approach - to study the processes of working capital enterprises, logical method and simulation - to systematize information security of these processes. Results of investigations to determine the characteristic...

  18. Comparing Sources of Storm-Time Ring Current O+

    Science.gov (United States)

    Kistler, L. M.

    2015-12-01

    The first observations of the storm-time ring current composition using AMPTE/CCE data showed that the O+ contribution to the ring current increases significantly during storms. The ring current is predominantly formed from inward transport of the near-earth plasma sheet. Thus the increase of O+ in the ring current implies that the ionospheric contribution to the plasma sheet has increased. The ionospheric plasma that reaches the plasma sheet can come from both the cusp and the nightside aurora. The cusp outflow moves through the lobe and enters the plasma sheet through reconnection at the near-earth neutral line. The nightside auroral outflow has direct access to nightside plasma sheet. Using data from Cluster and the Van Allen Probes spacecraft, we compare the development of storms in cases where there is a clear input of nightside auroral outflow, and in cases where there is a significant cusp input. We find that the cusp input, which enters the tail at ~15-20 Re becomes isotropized when it crosses the neutral sheet, and becomes part of the hot (>1 keV) plasma sheet population as it convects inward. The auroral outflow, which enters the plasma sheet closer to the earth, where the radius of curvature of the field line is larger, does not isotropize or become significantly energized, but remains a predominantly field aligned low energy population in the inner magnetosphere. It is the hot plasma sheet population that gets accelerated to high enough energies in the inner magnetosphere to contribute strongly to the ring current pressure. Thus it appears that O+ that enters the plasma sheet further down the tail has a greater impact on the storm-time ring current than ions that enter closer to the earth.

  19. Cannibalism in Latin-Greek sources: its references in mythology and ancient philosophy

    Directory of Open Access Journals (Sweden)

    Domingo F. Sanz

    2013-06-01

    Full Text Available This article tries to analyze and comment on the greater amount of references regarding the phenomenon of cannibalism that there exists in Greek and Latin literary tradition. After reviewing many of the sources, it is possible to distinguish the different ways in which this tradition approached such phenomenon and to discover a common intention: starting from the mythology or the Homeric epic, going through the different philosophical trends and schools of thought, we will begin to realize and conclude that in many occasions there is a use of the concept of cannibalism to negatively define «the other», the outcast or foreigner, opening thus a topic that still survives nowadays.

  20. Current status for TRR-II Cold Neutron Source

    International Nuclear Information System (INIS)

    Lee, C.H.; Guung, T.C.; Lan, K.C.; Wang, C.H.; Chan, Y.K.; Shieh, D.J.

    2001-01-01

    The Taiwan Research Reactor (TRR) project (TRR-II) is carrying out at Institute of Nuclear Energy Research (INER) from October 1998 to December 2006. The purpose of Cold Neutron Source (CNS) project is to build entire CNS facility to generate cold neutrons within TRR-II reactor. The objective of CNS design is to install CNS facility with a competitive brightness of cold neutron beam to other facilities in the world. Based on the TRR-II CNS project schedule, the conceptual design for TRR-II CNS facility has been completed and the mock-up test facility for full-scale hydrogen loop has been designed. (author)

  1. CURRENT STUDY ON THE FUNDING SOURCES COVERAGE OF CURRENT ASSETS TO COMPANIES LISTED ON THE BUCHAREST STOCK EXCHANGE

    Directory of Open Access Journals (Sweden)

    Teodor HADA

    2014-06-01

    Full Text Available This paper presents issues about the coverage with financing sources of current assets for 64 companies listed on the Bucharest Stock Exchange. The aim of the study is to see how to calculate indicators specific to current assets and the general framework offered as whole analysis of the financing sources of current assets. The introduction of the paper presents the objective, the research methodology and the novelties brought by this study. Further on, this study shows the various views of the authors about the concept of "current assets", financing sources of current assets, the calculation of net working capital, setting the limits of the normal working capital and determining the speed of rotation. After that was done, based on the theory, a case study was performed, for companies covered in this study. Conclusions focused on determining the final data about what was detailed in the previous paragraphs.

  2. High-current Standing Wave Linac With Gyrocon Power Source

    CERN Document Server

    Karliner, M M; Makarov, I G; Nezhevenko, O A; Ostreiko, G N; Persov, B Z; Serdobintsev, G V

    2004-01-01

    A gyrocon together with high-voltage 1.5 MeV accelerator ELIT-3A represents a power generator at 430 MHz serving for linear electron accelerator pulse driving. The facility description and results of calorimetric measurements of ELIT-3A electron beam power and accelerated beam at the end of accelerator are presented in the paper. 2.2 amps of pulsed current have been obtained at electron energy of 20 MeV. The achieved energy conversion efficiency is about 55%.

  3. Sources and sinks of Earth's ring current populations

    Science.gov (United States)

    Mauk, B.

    2017-12-01

    Processes that modify and transport current-carrying particles into and out of Earth's ring current regions are overviewed and discussed here with a focus on outstanding mysteries and uncertainties. Examples of such mysteries include the following. Some modeling and observational approaches point to a need for storm-time enhancements in the global electric field configuration to help bring magnetotail populations into the inner magnetosphere. And yet, electric field measurements from several missions, most recently the Van Allen Probes, suggest that only highly transient enhancements occur in critical regions that connect the outer and inner regions. Global enhancements appear to be internally generated rather than necessarily being driven from the outside. Another sample mystery involves the processes that give rise to the sometimes initial prompt recovery of the magnetic storm indice DST, given that loss processes traditionally invoked are likely too slow. Wave losses, such as those engendered by Electromagnetic Ion Cyclotron (EMIC) waves, may be responsible, but observational support for such a solution is lacking. These and other uncertainties are discussed with a goal of addressing how they might be addressed with the present great constellation of Earth-orbiting spacecraft, most recently joined by MMS and Arase (ERG).

  4. Current Practices of Measuring and Reference Range Reporting of Free and Total Testosterone in the United States.

    Science.gov (United States)

    Le, Margaret; Flores, David; May, Danica; Gourley, Eric; Nangia, Ajay K

    2016-05-01

    The evaluation and management of male hypogonadism should be based on symptoms and on serum testosterone levels. Diagnostically this relies on accurate testing and reference values. Our objective was to define the distribution of reference values and assays for free and total testosterone by clinical laboratories in the United States. Upper and lower reference values, assay methodology and source of published reference ranges were obtained from laboratories across the country. A standardized survey was reviewed with laboratory staff via telephone. Descriptive statistics were used to tabulate results. We surveyed a total of 120 laboratories in 47 states. Total testosterone was measured in house at 73% of laboratories. At the remaining laboratories studies were sent to larger centralized reference facilities. The mean ± SD lower reference value of total testosterone was 231 ± 46 ng/dl (range 160 to 300) and the mean upper limit was 850 ± 141 ng/dl (range 726 to 1,130). Only 9% of laboratories where in-house total testosterone testing was performed created a reference range unique to their region. Others validated the instrument recommended reference values in a small number of internal test samples. For free testosterone 82% of laboratories sent testing to larger centralized reference laboratories where equilibrium dialysis and/or liquid chromatography with mass spectrometry was done. The remaining laboratories used published algorithms to calculate serum free testosterone. Reference ranges for testosterone assays vary significantly among laboratories. The ranges are predominantly defined by limited population studies of men with unknown medical and reproductive histories. These poorly defined and variable reference values, especially the lower limit, affect how clinicians determine treatment. Copyright © 2016 American Urological Association Education and Research, Inc. Published by Elsevier Inc. All rights reserved.

  5. Characteristics of a High Current Helicon Ion Source With High Monatomic Fraction

    International Nuclear Information System (INIS)

    Jung, Hwa-Dong; Chung, Kyoung-Jae; Hwang, Yong-Seok

    2006-01-01

    Applications of neutron need compact and high yield neutron sources as well as very intense neutron sources from giant devices such as accelerators. Ion source based neutron sources using nuclear fusion reactions such as D(d, 3He)n, D(t, 4He)n can meet the requirements. This type of neutron generators can be simply composed of an ion source and a target. High-performance neutron generators with high yield require ion sources with high beam current, high monatomic fraction and long lifetime. Helicon ion source can meet these requirements. To make high current ion source, characteristics of helicon plasma such as high plasma density can be utilized. Moreover, efficient plasma heating with RF power lead high fraction of monatomic ion beam. Here, Characteristics of helicon plasma sources are described. Design and its performances of a helicon ion source are presented

  6. A global multicenter study on reference values: 2. Exploration of sources of variation across the countries.

    Science.gov (United States)

    Ichihara, Kiyoshi; Ozarda, Yesim; Barth, Julian H; Klee, George; Shimizu, Yoshihisa; Xia, Liangyu; Hoffmann, Mariza; Shah, Swarup; Matsha, Tandi; Wassung, Janette; Smit, Francois; Ruzhanskaya, Anna; Straseski, Joely; Bustos, Daniel N; Kimura, Shogo; Takahashi, Aki

    2017-04-01

    The intent of this study, based on a global multicenter study of reference values (RVs) for serum analytes was to explore biological sources of variation (SVs) of the RVs among 12 countries around the world. As described in the first part of this paper, RVs of 50 major serum analytes from 13,396 healthy individuals living in 12 countries were obtained. Analyzed in this study were 23 clinical chemistry analytes and 8 analytes measured by immunoturbidimetry. Multiple regression analysis was performed for each gender, country by country, analyte by analyte, by setting four major SVs (age, BMI, and levels of drinking and smoking) as a fixed set of explanatory variables. For analytes with skewed distributions, log-transformation was applied. The association of each source of variation with RVs was expressed as the partial correlation coefficient (r p ). Obvious gender and age-related changes in the RVs were observed in many analytes, almost consistently between countries. Compilation of age-related variations of RVs after adjusting for between-country differences revealed peculiar patterns specific to each analyte. Judged fromthe r p , BMI related changes were observed for many nutritional and inflammatory markers in almost all countries. However, the slope of linear regression of BMI vs. RV differed greatly among countries for some analytes. Alcohol and smoking-related changes were observed less conspicuously in a limited number of analytes. The features of sex, age, alcohol, and smoking-related changes in RVs of the analytes were largely comparable worldwide. The finding of differences in BMI-related changes among countries in some analytes is quite relevant to understanding ethnic differences in susceptibility to nutritionally related diseases. Copyright © 2016 The Authors. Published by Elsevier B.V. All rights reserved.

  7. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...

  8. A radio/optical reference frame. 5: Additional source positions in the mid-latitude southern hemisphere

    Science.gov (United States)

    Russell, J. L.; Reynolds, J. E.; Jauncey, D. L.; de Vegt, C.; Zacharias, N.; Ma, C.; Fey, A. L.; Johnston, K. J.; Hindsley, R.; Hughes, J. A.; Malin, D. F.; White, G. L.; Kawaguchi, N.; Takahashi, Y.

    1994-01-01

    We report new accurate radio position measurements for 30 sources, preliminary positions for two sources, improved radio postions for nine additional sources which had limited previous observations, and optical positions and optical-radio differences for six of the radio sources. The Very Long Baseline Interferometry (VLBI) observations are part of the continuing effort to establish a global radio reference frame of about 400 compact, flat spectrum sources, which are evenly distributed across the sky. The observations were made using Mark III data format in four separate sessions in 1988-89 with radio telescopes at Tidbinbilla, Australia, Kauai, USA, and Kashima, Japan. We observed a total of 54 sources, including ten calibrators and three which were undetected. The 32 new source positions bring the total number in the radio reference frame catalog to 319 (172 northern and 147 southern) and fill in the zone -25 deg greater than delta greater than -45 deg which, prior to this list, had the lowest source density. The VLBI positions have an average formal precision of less than 1 mas, although unknown radio structure effects of about 1-2 mas may be present. The six new optical postion measurements are part of the program to obtain positions of the optical counterparts of the radio reference frame source and to map accurately the optical on to the radio reference frames. The optical measurements were obtained from United States Naval Observatory (USNO) Black Birch astrograph plates and source plates from the AAT, and Kitt Peak National Observatory (KPNO) 4 m, and the European Southern Observatory (ESO) Schmidt. The optical positions have an average precision of 0.07 sec, mostly due to the zero point error when adjusted to the FK5 optical frame using the IRS catalog. To date we have measured optical positions for 46 sources.

  9. The moon as a radiometric reference source for on-orbit sensor stability calibration

    Science.gov (United States)

    Stone, T.C.

    2009-01-01

    The wealth of data generated by the world's Earth-observing satellites, now spanning decades, allows the construction of long-term climate records. A key consideration for detecting climate trends is precise quantification of temporal changes in sensor calibration on-orbit. For radiometer instruments in the solar reflectance wavelength range (near-UV to shortwave-IR), the Moon can be viewed as a solar diffuser with exceptional stability properties. A model for the lunar spectral irradiance that predicts the geometric variations in the Moon's brightness with ???1% precision has been developed at the U.S. Geological Survey in Flagstaff, AZ. Lunar model results corresponding to a series of Moon observations taken by an instrument can be used to stabilize sensor calibration with sub-percent per year precision, as demonstrated by the Sea-viewing Wide Field-of-view Sensor (SeaWiFS). The inherent stability of the Moon and the operational model to utilize the lunar irradiance quantity provide the Moon as a reference source for monitoring radiometric calibration in orbit. This represents an important capability for detecting terrestrial climate change from space-based radiometric measurements.

  10. Development of a Reference Dose for Perchlorate: Current Issues and Status

    Science.gov (United States)

    Pleus, R. C.; Goodman, G.; Mattie, D. R.

    2000-01-01

    The perchlorate anion (ClO4) is typically manufactured as the ammonium salt. The most common use of ammonium perchlorate is in the aerospace program as a component of solid rocket fuel. The perchlorate anion is exceedingly stable under environmental conditions and has been found in ground and surface waters in CA, NV, UT, AZ, TX, AK, NY, MD, WV and FL. The National Center for Environmental Assessment (NCEA) of the U.S. Environmental Protection Agency (US EPA) is in the process of developing an oral reference dose (RfD) for perchlorate. An oral RfD is a body-weight-adjusted dose that can be consumed daily over an entire lifetime with the expectation of no adverse health effects. Once developed, the new RfD will be used by US EPA as the basis of a safe-drinking-water level (SDWL) guideline. US EPA and regional regulatory agencies will then jointly or separately propose clean-up action levels for ground and surface waters at contaminated sites. The toxicological database on CIO4- as of March 1997 was determined by an expert peer-review panel to be inadequate for the purpose of deriving an oral RfD. For example, little or no experimental data existed on the subchronic, reproductive, or developmental toxicity of perchlorate. To fill gaps in the toxicological database, eight animal studies were designed by a government-industry consortium that included US EPA and AFRL. These studies were performed in 1997-1998. It has been known for many years that in the thyroid, high doses of perchlorate block the function of iodide by competing for iodide binding sites. Perchlorate was used in the 1950s-60s as a treatment for Graves' disease (a hyperthyroid condition). Because of what was already known about the pharmacological mode of action of perchlorate, specific concerns addressed in the design of the recent animal studies included the potential for developmental toxicity, notably neurological development. Upon review of complete study reports from four of the studies and

  11. Balanced Current Control Strategy for Current Source Rectifier Stage of Indirect Matrix Converter under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yeongsu Bak

    2016-12-01

    Full Text Available This paper proposes a balanced current control strategy for the current source rectifier (CSR stage of an indirect matrix converter (IMC under unbalanced grid voltage conditions. If the three-phase grid connected to the voltage source inverter (VSI of the IMC has unbalanced voltage conditions, it affects the currents of the CSR stage and VSI stage, and the currents are distorted. Above all, the distorted currents of the CSR stage cause instability in the overall system, which can affect the life span of the system. Therefore, in this paper, a control strategy for balanced currents in the CSR stage is proposed. To achieve balanced currents in the CSR stage, the VSI stage should receive DC power without ripple components from the CSR stage. This is implemented by controlling the currents in the VSI stage. Therefore, the proposed control strategy decouples the positive and negative phase-sequence components existing in the unbalanced voltages and currents of the VSI stage. Using the proposed control strategy under unbalanced grid voltage conditions, the stability and life span of the overall system can be improved. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

  12. Design of the LC+trap filter for a current source rectifier

    DEFF Research Database (Denmark)

    Min, Huang; Wang, Xiongfei; Loh, Poh Chiang

    2015-01-01

    This paper investigates an LC + trap filter for current source converters to improve the switching harmonic attenuation. The resonant frequency characteristics of the filter of current source rectifier are analyzed. A filter design procedure is proposed based on the input power factor, filter...

  13. Solar quiet day ionospheric source current in the West African region.

    Science.gov (United States)

    Obiekezie, Theresa N; Okeke, Francisca N

    2013-05-01

    The Solar Quiet (Sq) day source current were calculated using the magnetic data obtained from a chain of 10 magnetotelluric stations installed in the African sector during the French participation in the International Equatorial Electrojet Year (IEEY) experiment in Africa. The components of geomagnetic field recorded at the stations from January-December in 1993 during the experiment were separated into the source and (induced) components of Sq using Spherical Harmonics Analysis (SHA) method. The range of the source current was calculated and this enabled the viewing of a full year's change in the source current system of Sq.

  14. Solar quiet day ionospheric source current in the West African region

    Directory of Open Access Journals (Sweden)

    Theresa N. Obiekezie

    2013-05-01

    Full Text Available The Solar Quiet (Sq day source current were calculated using the magnetic data obtained from a chain of 10 magnetotelluric stations installed in the African sector during the French participation in the International Equatorial Electrojet Year (IEEY experiment in Africa. The components of geomagnetic field recorded at the stations from January–December in 1993 during the experiment were separated into the source and (induced components of Sq using Spherical Harmonics Analysis (SHA method. The range of the source current was calculated and this enabled the viewing of a full year’s change in the source current system of Sq.

  15. Hall Current Plasma Source Having a Center-Mounted or a Surface-Mounted Cathode

    Science.gov (United States)

    Martinez, Rafael A. (Inventor); Williams, John D. (Inventor); Moritz, Jr., Joel A. (Inventor); Farnell, Casey C. (Inventor)

    2018-01-01

    A miniature Hall current plasma source apparatus having magnetic shielding of the walls from ionized plasma, an integrated discharge channel and gas distributor, an instant-start hollow cathode mounted to the plasma source, and an externally mounted keeper, is described. The apparatus offers advantages over other Hall current plasma sources having similar power levels, including: lower mass, longer lifetime, lower part count including fewer power supplies, and the ability to be continuously adjustable to lower average power levels using pulsed operation and adjustment of the pulse duty cycle. The Hall current plasma source can provide propulsion for small spacecraft that either do not have sufficient power to accommodate a propulsion system or do not have available volume to incorporate the larger propulsion systems currently available. The present low-power Hall current plasma source can be used to provide energetic ions to assist the deposition of thin films in plasma processing applications.

  16. Analysis of Peak-to-Peak Current Ripple Amplitude in Seven-Phase PWM Voltage Source Inverters

    Directory of Open Access Journals (Sweden)

    Gabriele Grandi

    2013-08-01

    Full Text Available Multiphase systems are nowadays considered for various industrial applications. Numerous pulse width modulation (PWM schemes for multiphase voltage source inverters with sinusoidal outputs have been developed, but no detailed analysis of the impact of these modulation schemes on the output peak-to-peak current ripple amplitude has been reported. Determination of current ripple in multiphase PWM voltage source inverters is important for both design and control purposes. This paper gives the complete analysis of the peak-to-peak current ripple distribution over a fundamental period for multiphase inverters, with particular reference to seven-phase VSIs. In particular, peak-to-peak current ripple amplitude is analytically determined as a function of the modulation index, and a simplified expression to get its maximum value is carried out. Although reference is made to the centered symmetrical PWM, being the most simple and effective solution to maximize the DC bus utilization, leading to a nearly-optimal modulation to minimize the RMS of the current ripple, the analysis can be readily extended to either discontinuous or asymmetrical modulations, both carrier-based and space vector PWM. A similar approach can be usefully applied to any phase number. The analytical developments for all different sub-cases are verified by numerical simulations.

  17. Organic Production: Recent Publications and Current Information Sources. Special Reference Briefs: SRB 95-01.

    Science.gov (United States)

    National Agricultural Library, Beltsville, MD.

    The activities of the National Organic Standards Board, coupled with the movement towards "sustainable systems" and continued consumer support for organic foods, have made farming organically an increasingly viable alternative for many U.S. farmers. This list of resources is provided to accommodate increasing requests for information on…

  18. Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    -sequence current components is becoming necessary for achieving new capabilities like the reactive power injection during a grid fault. This paper deals with a fundamental issue in this topic, i.e., the performance of the current controller. Classical dq controllers, which are extensively used in industrial...

  19. Beam Current Increase and Cathode Lifetime Improvement of KOTRON-13 Ion Source

    International Nuclear Information System (INIS)

    Lee, W. K.; Chae, S. K.; Song, J. Y.; Im, G. S.; Cho, B. O.

    2010-01-01

    Technology of cyclotron has been actively developed to meet the increasing requirement output of medical radioactive isotopes for PET. KOTRON-13 is produced with low negative hydrogen ion beam current owing to the low efficiency of proton beam current compared with foreign cyclotron. In the defect there from, the lifetime of cathode is around 5,000min, which requires frequent maintenance period, and the target beam current is maximum 50uA at a poor efficiency compared with the inflow quantity of hydrogen gas and that of inflicting arc current. Considering above affairs, we have to improve the PIG ion source extraction efficiency of KOTRON-13 in order to lift beam current. Mostly the ion source of cyclotron less than 30Mev comes from the use of PIG ion source mainly with the method of cold cathode or hot cathode. However, the cyclotron of 30Mev grade of EBCO or IBA uses the external ion source and uses ion source with cusp type of good withdrawal efficiency. This type requires high voltage, and transports ion from ion source to cyclotron, which requires precise transportation equipment. And entering cyclotron requires a high quality of inflictor with a high defect rate, but high current cyclotron has no choice but to use ion source of such a method. But the cyclotron using PET with the beam current less than 100uA uses PIG ion source of KOTRON-13 with a reasonable maintenance cost

  20. Determination of the reference air kerma rate for 192Ir brachytherapy sources and the related uncertainty

    International Nuclear Information System (INIS)

    Dijk, Eduard van; Kolkman-Deurloo, Inger-Karine K.; Damen, Patricia M. G.

    2004-01-01

    Different methods exist to determine the air kerma calibration factor of an ionization chamber for the spectrum of a 192 Ir high-dose-rate (HDR) or pulsed-dose-rate (PDR) source. An analysis of two methods to obtain such a calibration factor was performed: (i) the method recommended by [Goetsch et al., Med. Phys. 18, 462-467 (1991)] and (ii) the method employed by the Dutch national standards institute NMi [Petersen et al., Report S-EI-94.01 (NMi, Delft, The Netherlands, 1994)]. This analysis showed a systematic difference on the order of 1% in the determination of the strength of 192 Ir HDR and PDR sources depending on the method used for determining the air kerma calibration factor. The definitive significance of the difference between these methods can only be addressed after performing an accurate analysis of the associated uncertainties. For an NE 2561 (or equivalent) ionization chamber and an in-air jig, a typical uncertainty budget of 0.94% was found with the NMi method. The largest contribution in the type-B uncertainty is the uncertainty in the air kerma calibration factor for isotope i, N k i , as determined by the primary or secondary standards laboratories. This uncertainty is dominated by the uncertainties in the physical constants for the average mass-energy absorption coefficient ratio and the stopping power ratios. This means that it is not foreseeable that the standards laboratories can decrease the uncertainty in the air kerma calibration factors for ionization chambers in the short term. When the results of the determination of the 192 Ir reference air kerma rates in, e.g., different institutes are compared, the uncertainties in the physical constants are the same. To compare the applied techniques, the ratio of the results can be judged by leaving out the uncertainties due to these physical constants. In that case an uncertainty budget of 0.40% (coverage factor=2) should be taken into account. Due to the differences in approach between the

  1. The Poisson alignment reference system implementation at the Advanced Photon Source

    International Nuclear Information System (INIS)

    Feier, I.

    1998-01-01

    The Poisson spot was established using a collimated laser beam from a 3-mW diode laser. It was monitored on a quadrant detector and found to be very sensitive to vibration and air disturbances. Therefore, for future work we strongly recommend a sealed vacuum tube in which the Poisson line may be propagated. A digital single-axis feedback system was employed to generate an straight line reference (SLR) on the X axis. Pointing accuracy was better than 8 ± 2 microns at a distance of 5 m. The digital system was found to be quite slow with a maximum bandwidth of 47 ± 9 Hz. Slow drifts were easily corrected but any vibration over 5 Hz was not. We recommend an analog proportional-integral-derivative (PID) controller for high bandwidth and smooth operation of the kinematic mirror. Although the Poisson alignment system (PAS) at the Advanced Photon Source is still in its infancy, it already shows great promise as a possible alignment system for the low-energy undulator test line (LEUTL). Since components such as wigglers and quadruples will initially be aligned with respect to each other using conventional means and mounted on some kind of rigid rail, the goal would be to align six to ten such rails over a distance of about 30 m. The PAS could be used to align these rails by mounting a sphere at the joint between two rails. These spheres would need to be in a vacuum pipe to eliminate the refractive effects of air. Each sphere would not be attached to either rail but instead to a flange connecting the vacuum pipes of each rail. Thus the whole line would be made up of straight, rigid segments that could be aligned by moving the joints. Each sphere would have its own detector, allowing the operators to actively monitor the position of each joint and therefore the overall alignment of the system

  2. A Review on Current Reference Calculation of Three-Phase Grid-Connected PV Converters under Grid Faults

    DEFF Research Database (Denmark)

    Afshari, Ehsan; Moradi, Gholam Reza; Yang, Yongheng

    2017-01-01

    Unbalanced grid voltage dips may lead to unbalanced non-sinusoidal current injections, dc-link voltage oscillations, and active and/or reactive power oscillations with twice the grid fundamental frequency in three-phase grid-connected Photovoltaic (PV) systems. Double grid frequency oscillations...... of the most important issues that should be coped with for a reliable operation of grid-connected converters under unbalanced grid faults. Accordingly, this paper reviews the existing CRC methods and presents a current reference generation method, which can have 16 unique modes. Issues are also investigated...... at the dc-link of the conventional two-stage PV inverters can further deteriorate the dc-link capacitor, which is one of the most life-limiting components in the system. Proper controls of these converters may efficiently address this problem. In those solutions, Current Reference Calculation (CRC) is one...

  3. Influence of current limitation on voltage stability with voltage sourced converter HVDC

    DEFF Research Database (Denmark)

    Zeni, Lorenzo; Jóhannsson, Hjörtur; Hansen, Anca Daniela

    2013-01-01

    A first study of voltage stability with relevant amount of Voltage Sourced Converter based High Voltage Direct Current (VSC-HVDC) transmission is presented, with particular focus on the converters’ behaviour when reaching their rated current. The detrimental effect of entering the current...

  4. Turbulent structures in cylindrical density currents in a rotating frame of reference

    Science.gov (United States)

    Salinas, Jorge S.; Cantero, Mariano I.; Dari, Enzo A.; Bonometti, Thomas

    2018-06-01

    Gravity currents are flows generated by the action of gravity on fluids with different densities. In some geophysical applications, modeling such flows makes it necessary to account for rotating effects, modifying the dynamics of the flow. While previous works on rotating stratified flows focused on currents of large Coriolis number, the present work focuses on flows with small Coriolis numbers (i.e. moderate-to-large Rossby numbers). In this work, cylindrical rotating gravity currents are investigated by means of highly resolved simulations. A brief analysis of the mean flow evolution to the final state is presented to provide a complete picture of the flow dynamics. The numerical results, showing the well-known oscillatory behavior of the flow (inertial waves) and a final state lens shape (geostrophic adjustment), are in good agreement with experimental observations and theoretical models. The turbulent structures in the flow are visualized and described using, among others, a stereoscopic visualization and videos as supplementary material. In particular, the structure of the lobes and clefts at the front of the current is presented in association to local turbulent structures. In rotating gravity currents, the vortices observed at the lobes front are not of hairpin type but are rather of Kelvin-Helmholtz type.

  5. Recent results with a high-current, heavy-ion source system

    International Nuclear Information System (INIS)

    Keller, R.; Spaedtke, P.; Emig, H.

    1986-01-01

    In the last conference of this series, an improved high-current ion source for gases, CORDIS was presented. This source has been further developed to allow the processing of substances which are not volatile at room temperature. One of these modifications, HORDIS, incorporates an oven whereas the third version works at rather moderate temperatures and can be fed through a slightly heated external bottle. With this source system, high-current ion beams in the 100 mA range can be produced for a considerable part of the periodic table. Operation parameters and experiences with the sources are discussed, and the most recent results for all versions are given. (author)

  6. A Circulating-Current Suppression Method for Parallel-Connected Voltage-Source Inverters With Common DC and AC Buses

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    This paper presents a theoretical study with experimental validation of a circulating-current suppression method for parallel operation of three-phase voltage source inverters (VSI), which may be suitable for modular parallel uninterruptible power supply systems or hybrid AC/DC microgrid applicat......This paper presents a theoretical study with experimental validation of a circulating-current suppression method for parallel operation of three-phase voltage source inverters (VSI), which may be suitable for modular parallel uninterruptible power supply systems or hybrid AC/DC microgrid......, and added into the conventional droop plus virtual impedance control. In the control architecture, the reference voltages of the inverters are generated by the primary control loop which consists of a droop control and a virtual impedance. The secondary control is used to compensate the voltage drop...

  7. Time-Dependent Selection of an Optimal Set of Sources to Define a Stable Celestial Reference Frame

    Science.gov (United States)

    Le Bail, Karine; Gordon, David

    2010-01-01

    Temporal statistical position stability is required for VLBI sources to define a stable Celestial Reference Frame (CRF) and has been studied in many recent papers. This study analyzes the sources from the latest realization of the International Celestial Reference Frame (ICRF2) with the Allan variance, in addition to taking into account the apparent linear motions of the sources. Focusing on the 295 defining sources shows how they are a good compromise of different criteria, such as statistical stability and sky distribution, as well as having a sufficient number of sources, despite the fact that the most stable sources of the entire ICRF2 are mostly in the Northern Hemisphere. Nevertheless, the selection of a stable set is not unique: studying different solutions (GSF005a and AUG24 from GSFC and OPA from the Paris Observatory) over different time periods (1989.5 to 2009.5 and 1999.5 to 2009.5) leads to selections that can differ in up to 20% of the sources. Observing, recording, and network improvement are some of the causes, showing better stability for the CRF over the last decade than the last twenty years. But this may also be explained by the assumption of stationarity that is not necessarily right for some sources.

  8. Voltage-regulating constant-current sources in a linear induction accelerator

    International Nuclear Information System (INIS)

    Zhao Juan; Cao Kefeng; Deng Jianjun; Zhu Lijun; Yang Jia; Ye Chao; Huang Bin; Cao Ningxiang; Dong Jinxuan; Zhang Jichang; Yu Zhiguo; Chen Min

    2002-01-01

    Constant-current Sources are one of key units in a linear induction accelerator. The requirements for the sources are to supply stable direct current of high power for the induction coil, be easy to computer-control and highly stable and reliable. Applying the technique of linear current source regulating in series, the primary voltage of the power transformer is regulated through an MJYS-JL-350A type three-phase alterative voltage-regulating module. The output current variation is 300-500 A when the load variation is 0.06-0.1 Ω and the voltage drop of the regulator tube is controlled within 8 V±2V when the variation of mains voltage is in ±10%. Both the current ripple and stability meet the technical requirements. The constant-current sources are controlled through an industrial controller. For each of the constant-current sources has a smallest system comprised of 8051 which is communication-controlled through a RS-485 interface, the sources can be controlled remotely

  9. Letter Report on 500 nA Pulsed Current from Field Ionization Source

    International Nuclear Information System (INIS)

    Ellsworth, Jennifer L.

    2013-01-01

    We recently produced a milestone 500 nA of pulsed current using 40 Ir field ionizer electrodes in our ion source. In conclusion, we have produced the milestone pulsed current of 500 nA using 40 electrochemically etched iridium tips in a field ionization source. The pulsed current output is repeatable and scales as expected with gas fill pressure and bias voltage. We expect these current will be sufficient to produce neutral yields of 1 · 10 7 DT n/s.

  10. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

    Science.gov (United States)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M.

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method. PMID:28192436

  11. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions.

    Science.gov (United States)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz; Miveh, Mohammad Reza; Guerrero, Josep M

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions. It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed to control the active and reactive power and harmonic current compensation, and it also corrects the system unbalance. The proposed control method features the synchronous reference frame (SRF) method. Simulation results are presented to demonstrate the effective performance of the proposed method.

  12. High-current negative hydrogen ion beam production in a cesium-injected multicusp source

    International Nuclear Information System (INIS)

    Takeiri, Y.; Tsumori, K.; Kaneko, O.

    1997-01-01

    A high-current negative hydrogen ion source has been developed, where 16.2 A of the H - current was obtained with a current density of 31 mA/cm 2 . The ion source is a multicusp source with a magnetic filter for negative ion production, and cesium vapor is injected into the arc chamber, leading to enhancement of the negative ion yields. The cesium-injection effects are discussed, based on the experimental observations. Although the surface production of the negative ions on the cesium-covered plasma grid is thought to be a dominant mechanism of the H - current enhancement, the cesium effects in the plasma volume, such as the cesium ionization and the electron cooling, are observed, and could contribute to the improved operation of the negative ion source. (author)

  13. Method and system for a gas tube-based current source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Bray, James William; Sommerer, Timothy John; Zhou, Rui; Zhang, Di

    2017-08-29

    A high-voltage direct-current (HVDC) transmission system includes an alternating current (AC) electrical source and a power converter channel that includes an AC-DC converter electrically coupled to the electrical source and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and the DC-AC inverter each include a plurality of legs that includes at least one switching device. The power converter channel further includes a commutating circuit communicatively coupled to one or more switching devices. The commutating circuit is configured to "switch on" one of the switching devices during a first portion of a cycle of the H-bridge switching circuits and "switch off" the switching device during a second portion of the cycle of the first and second H-bridge switching circuits.

  14. Development of the High Current Ion Source for Neutral Beam Injection

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Hun Ju; Kim, S. H.; Jang, D. H. [Jae Ju University, Jaeju (Korea, Republic of)

    1997-08-01

    The scope of the 1st year research is to design an 140keV deuterium ion source which has a beam current of 30-40A. According to the collected data, the model of an ion source for NBI of KSTAR was established. The negative ion source, which has good neutralization effecting in high energy, was selected. To generate a plasma, the thoriated tungsten filament was adopted. To increase the efficiency of plasma, the multi cusp type magnetic field was attached. The magnetic field was calculated by POISSON code. The extraction structure was designed with EGUN code, to extract the high quality ion beam. The design of a high current ion source for NBI was carried out. To develop the high current ion source with the high operational stability and the long lifetime, the parameters including an arc current, gas pressure and extraction voltage should be optimized. If designed ion source would be fabricated, its parameters could be optimized experimentally. Through the optimization of the ion source parameter, the core technology for NBI is established and the experiment of current drive in the fusion device can be performed. This technology also can be applied to the synthesis of new material and semiconductor industry. 18 refs., 11 tabs., 19 figs. (author)

  15. the effect of current and relevant information sources on the use

    African Journals Online (AJOL)

    Admin

    reported similar findings at Yaba College of. Technology, Lagos. However, in a ... values. In other words, current information sources resulted in the use of the library. Jam (1992) identified lack of relevant information sources to be one of the problems facing library users and has ... Bachelor's degree holders. That those with.

  16. Current source enhancements in Electrical Impedance Spectroscopy (EIS) to cancel unwanted capacitive effects

    Science.gov (United States)

    Zarafshani, Ali; Bach, Thomas; Chatwin, Chris; Xiang, Liangzhong; Zheng, Bin

    2017-03-01

    Electrical Impedance Spectroscopy (EIS) has emerged as a non-invasive imaging modality to detect and quantify functional or electrical properties related to the suspicious tumors in cancer screening, diagnosis and prognosis assessment. A constraint on EIS systems is that the current excitation system suffers from the effects of stray capacitance having a major impact on the hardware subsystem as the EIS is an ill-posed inverse problem which depends on the noise level in EIS measured data and regularization parameter in the reconstruction algorithm. There is high complexity in the design of stable current sources, with stray capacitance reducing the output impedance and bandwidth of the system. To confront this, we have designed an EIS current source which eliminates the effect of stray capacitance and other impacts of the capacitance via a variable inductance. In this paper, we present a combination of operational CCII based on a generalized impedance converter (OCCII-GIC) with a current source. The aim of this study is to use the EIS system as a biomedical imaging technique, which is effective in the early detection of breast cancer. This article begins with the theoretical description of the EIS structure, current source topologies and proposes a current conveyor in application of a Gyrator to eliminate the current source limitations and its development followed by simulation and experimental results. We demonstrated that the new design could achieve a high output impedance over a 3MHz frequency bandwidth when compared to other types of GIC circuits combined with an improved Howland topology.

  17. Current knowledge of US metal and nonmetal miner health: Current and potential data sources for analysis of miner health status

    Science.gov (United States)

    Yeoman, K. M.; Halldin, C. N.; Wood, J.; Storey, E.; Johns, D.; Laney, A. S.

    2016-01-01

    ABSTRACT Little is known about the current health status of US metal and nonmetal (MNM) miners, in part because no health surveillance systems exist for this population. The National Institute for Occupational Safety and Health (NIOSH) is developing a program to characterize burden of disease among MNM miners. This report discusses current knowledge and potential data sources of MNM miner health. Recent national surveys were analyzed, and literature specific to MNM miner health status was reviewed. No robust estimates of disease prevalence were identified, and national surveys did not provide information specific to MNM miners. Because substantial gaps exist in the understanding of MNM miners' current health status, NIOSH plans to develop a health surveillance program for this population to guide intervention efforts to reduce occupational and personal risks for chronic illness. PMID:25658684

  18. Current prescription status of antihypertensive drugs with special reference to the use of diuretics in Japan.

    Science.gov (United States)

    Ibaraki, Ai; Goto, Wataru; Iura, Rie; Tominaga, Mitsuhiro; Tsuchihashi, Takuya

    2017-02-01

    The guidelines for the management of hypertension recommend the inclusion of diuretics, especially when three or more antihypertensive drugs are used. The present study investigated the current prescription status of antihypertensive drugs with a particular focus on the use of diuretics in a local district in Japan. Prescriptions, including antihypertensive drugs, were collected from a dispensing pharmacy of the Yahata Pharmacist Association, located in Kitakyushu City, in October 2014. Of the 10 585 prescriptions, calcium channel blockers (CCBs) were prescribed in 73.5%, followed by angiotensin II receptor blockers (ARB, 62.7%), diuretics (16.5%) and β-blockers (13.6%). The average number of drugs used was 1.80. The rates of prescription of diuretics for patients with one, two, three and four drugs were 0.6%, 13.1%, 55.2% and 82.6%, respectively. Diuretics were more frequently prescribed in elderly patients, and the prescription rate of doctors in hospitals was significantly higher than that of general practitioners (19.1% vs. 15.7%, Pdiuretics were prescribed combination tablets of hydrochlorothiazide with ARB, whereas trichlormethiazide (34.9%) and indapamide (19.8%) were used in other patients. Based on these findings, the use of diuretics remains limited, even among patients taking multiple antihypertensive drugs.

  19. Systematical and statistical errors in using reference light sources to calibrate TLD readers

    International Nuclear Information System (INIS)

    Burgkhardt, B.; Piesch, E.

    1981-01-01

    Three light sources, namely an NaI(Tl) scintillator + Ra, an NaI(Tl) scintillator + 14 C and a plastic scintillator + 14 C, were used during a period of 24 months for a daily check of two TLD readers: the Harshaw 2000 A + B and the Toledo 651. On the basis of light source measurements long-term changes and day-to-day fluctuations of the reader response were investigated. Systematical changes of the Toledo reader response of up to 6% during a working week are explained by nitrogen effects in the plastic scintillator light source. It was found that the temperature coefficient of the light source intensity was -0.05%/ 0 C for the plastic scintillator and -0.3%/ 0 C for the NaI(Tl) scintillator. The 210 Pb content in the Ra activated NaI(Tl) scintillator caused a time-dependent decrease in light source intensity of 3%/yr for the light source in the Harshaw reader. The internal light sources revealed a relative standard deviation of 0.5% for the Toledo reader and the Harshaw reader after respective reading times of 0.45 and 100 sec. (author)

  20. A current-mode voltage regulator with an embedded sub-threshold reference for a passive UHF RFID transponder

    International Nuclear Information System (INIS)

    Liu Zhongqi; Zhang Chun; Li Yongming; Wang Zhihua

    2010-01-01

    This paper presents a current-mode voltage regulator for a passive UHF RFID transponder. The passive tag power is extracted from RF energy through the RF-to-DC rectifier. Due to huge variations of the incoming RF power, the rectifier output voltage should be regulated to achieve a stable power supply. By accurately controlling the current flowing into the load with an embedded sub-threshold reference, the regulated voltage varies in a range of 1-1.3 V from -20 to 80 0 C, and a bandwidth of about 100 kHz is achieved for a fast power recovery. The circuit is fabricated in UMC 0.18 μm mixed-mode CMOS technology, and the current consumption is only 1 μA. (semiconductor integrated circuits)

  1. A current-mode voltage regulator with an embedded sub-threshold reference for a passive UHF RFID transponder

    Energy Technology Data Exchange (ETDEWEB)

    Liu Zhongqi [Department of Electronic Engineering, Tsinghua University, Beijing 100084 (China); Zhang Chun; Li Yongming; Wang Zhihua, E-mail: liu-zq04@mails.tsinghua.edu.c [Institute of Microelectronics, Tsinghua University, Beijing 100084 (China)

    2010-06-15

    This paper presents a current-mode voltage regulator for a passive UHF RFID transponder. The passive tag power is extracted from RF energy through the RF-to-DC rectifier. Due to huge variations of the incoming RF power, the rectifier output voltage should be regulated to achieve a stable power supply. By accurately controlling the current flowing into the load with an embedded sub-threshold reference, the regulated voltage varies in a range of 1-1.3 V from -20 to 80 {sup 0}C, and a bandwidth of about 100 kHz is achieved for a fast power recovery. The circuit is fabricated in UMC 0.18 {mu}m mixed-mode CMOS technology, and the current consumption is only 1 {mu}A. (semiconductor integrated circuits)

  2. Development of a high brightness, high current SRF photo-electron source for ERL applications

    Energy Technology Data Exchange (ETDEWEB)

    Neumann, Axel [Helmholtz-Zentrum Berlin (Germany); Collaboration: bERLinPro Team

    2016-07-01

    Energy recovery linacs (ERL) offer the potential to combine major beam properties of the two main domains of particle accelerators: The low emittance of linear accelerators and the high average beam current of storage rings, while also allowing to compress to short bunches below the ps regime. This makes among other applications ERLs an ideal candidate for future light sources. The beam properties of the ERL are given by the performance of the injection section and hence of the beam source. Helmholtz-Zentrum Berlin is currently designing and building a high average current all superconducting CW driven ERL as a prototype to demonstrate low normalized beam emittance of 1 mm*mrad at 100 mA and short pulses of about 2 ps. In this contribution we discuss the development of this class of a high brightness, high current SRF photo-electron source and present recent commissioning results. Also, alternative approaches at other laboratories are shortly reviewed.

  3. Hardware and Software of a Bipolar Current Source Controlled by PC

    Directory of Open Access Journals (Sweden)

    Mirjana Rajčić-Vujasinović

    2008-03-01

    Full Text Available This paper describes a realization of a bipolar current source developed by the paper's authors. The source is intended for use in galvanic and other industrial plants, where a pulse-reverse current supply (with the desired shape in time is required. A prototype of the device, which provides the outcome current intensity up to ± 50 A, has been constructed. The hardware of the source consists of a Pentium IV PC, a commercial ADDA converter, an interface of authors’ original construction as well as a current regulator. The application software is developed using a commercial packet LabView as the basis.

  4. The Role of Virtual Reference in Library Web Site Design: A Qualitative Source for Usage Data

    Science.gov (United States)

    Powers, Amanda Clay; Shedd, Julie; Hill, Clay

    2011-01-01

    Gathering qualitative information about usage behavior of library Web sites is a time-consuming process requiring the active participation of patron communities. Libraries that collect virtual reference transcripts, however, hold valuable data regarding how the library Web site is used that could benefit Web designers. An analysis of virtual…

  5. Motion Pictures: An Update Survey of Reference Sources, 1982-1988.

    Science.gov (United States)

    Block, Eleanor S.

    1989-01-01

    Surveys motion picture reference materials published since 1982. Materials are presented in the following categories: encyclopedic works about films, filmmakers and the industry; film criticism; people on the screen and behind it; horror, science fiction and Westerns; literature on film; catalogs and filmographies; and special collections. (70…

  6. The differential Howland current source with high signal to noise ratio for bioimpedance measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Liu, Jinzhen; Li, Gang; Lin, Ling, E-mail: linling@tju.edu.cn [State Key Laboratory of Precision Measurement Technology and Instruments, Tianjin University, Tianjin, People' s Republic of China, and Tianjin Key Laboratory of Biomedical Detecting Techniques and Instruments, Tianjin University, Tianjin (China); Qiao, Xiaoyan [College of Physics and Electronic Engineering, Shanxi University, Shanxi (China); Wang, Mengjun [School of Information Engineering, Hebei University of Technology, Tianjin (China); Zhang, Weibo [Institute of Acupuncture and Moxibustion China Academy of Chinese Medical Sciences, Beijing (China)

    2014-05-15

    The stability and signal to noise ratio (SNR) of the current source circuit are the important factors contributing to enhance the accuracy and sensitivity in bioimpedance measurement system. In this paper we propose a new differential Howland topology current source and evaluate its output characters by simulation and actual measurement. The results include (1) the output current and impedance in high frequencies are stabilized after compensation methods. And the stability of output current in the differential current source circuit (DCSC) is 0.2%. (2) The output impedance of two current circuits below the frequency of 200 KHz is above 1 MΩ, and below 1 MHz the output impedance can arrive to 200 KΩ. Then in total the output impedance of the DCSC is higher than that of the Howland current source circuit (HCSC). (3) The SNR of the DCSC are 85.64 dB and 65 dB in the simulation and actual measurement with 10 KHz, which illustrates that the DCSC effectively eliminates the common mode interference. (4) The maximum load in the DCSC is twice as much as that of the HCSC. Lastly a two-dimensional phantom electrical impedance tomography is well reconstructed with the proposed HCSC. Therefore, the measured performance shows that the DCSC can significantly improve the output impedance, the stability, the maximum load, and the SNR of the measurement system.

  7. Generator localization by current source density (CSD): Implications of volume conduction and field closure at intracranial and scalp resolutions

    Science.gov (United States)

    Tenke, Craig E.; Kayser, Jürgen

    2012-01-01

    The topographic ambiguity and reference-dependency that has plagued EEG/ERP research throughout its history are largely attributable to volume conduction, which may be concisely described by a vector form of Ohm’s Law. This biophysical relationship is common to popular algorithms that infer neuronal generators via inverse solutions. It may be further simplified as Poisson’s source equation, which identifies underlying current generators from estimates of the second spatial derivative of the field potential (Laplacian transformation). Intracranial current source density (CSD) studies have dissected the “cortical dipole” into intracortical sources and sinks, corresponding to physiologically-meaningful patterns of neuronal activity at a sublaminar resolution, much of which is locally cancelled (i.e., closed field). By virtue of the macroscopic scale of the scalp-recorded EEG, a surface Laplacian reflects the radial projections of these underlying currents, representing a unique, unambiguous measure of neuronal activity at scalp. Although the surface Laplacian requires minimal assumptions compared to complex, model-sensitive inverses, the resulting waveform topographies faithfully summarize and simplify essential constraints that must be placed on putative generators of a scalp potential topography, even if they arise from deep or partially-closed fields. CSD methods thereby provide a global empirical and biophysical context for generator localization, spanning scales from intracortical to scalp recordings. PMID:22796039

  8. Early effect of NEURAPAS® balance on current source density (CSD of human EEG

    Directory of Open Access Journals (Sweden)

    Koch Klaus

    2011-08-01

    Full Text Available Abstract Psychiatric patients often suffer from stress, anxiety and depression. Various plant extracts are known to fight stress (valerian, anxiety (passion flower or depression (St. John's wort. NEURAPAS® balance is a mixture of these three extracts and has been designed to cover this complex of psychiatric conditions. The study was initiated to quantitatively assess the effect of this combination on brain electric activity. Method Quantitative electroencephalogram (EEG current source density (CSD recording from 16 healthy male and female human volunteers (average age 49 years was used in a randomized, placebo-controlled cross over study. Recordings were performed 0. 5, 1. 5, 3 and 4 hours after administration of the preparations under the conditions of 6 min eyes open and 5 min d2 concentration test, mathematical calculation test and memory test, respectively. All variables (electric power within 6 frequency ranges at 17 electrode positions were fed into a linear discriminant analysis (eyes open condition. In the presence of mental load these variables were used to construct brain maps of frequency changes. Results Under the condition of mental load, centro-parietal spectral power remained statistically significantly lower within alpha1, alpha2 and beta1 frequencies in the presence of verum in comparison to placebo. Discriminant analysis revealed a difference to placebo 3 and 4 hours after intake of 6 tablets of NEURAPAS® balance. Data location within the polydimensional space was projected into the area of the effects of sedative and anti-depressive reference drugs tested earlier under identical conditions. Results appeared closer to the effects of fluoxetine than to St. John's wort. Conclusions Analysis of the neurophysiological changes following the intake of NEURAPAS® balance revealed a similarity of frequency changes to those of calming and anti-depressive drugs on the EEG without impairment of cognition. Trial registration Clinical

  9. Pulse width modulated buck-boost five-level current source inverters

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Gao, F.; Loh, P.C.

    2008-01-01

    , resulting in the natural balance of input current. For maintaining the normalized volt-sec average unchanged, the alternative phase opposition disposition (APOD) modulation scheme with typical gating signal mapping technique from voltage source inverter (VSI) to CSI can be assumed to control the five......This paper presents new five-level current source inverters (CSIs) with voltage/current buck-boost capability. Being different from the existing multilevel CSI, the proposed CSIs were first designed to regulate the flowing path of dc input current by controlling two additional active switches......-level buck-boost CSIs. Next by observing the hidden current charging path during inductive charging interval under APOD modulation, it is noted that the buck-boost five-level CSI can then be further modified with lesser active component without degrading output performance. To verify the theoretical findings...

  10. Design of current source for multi-frequency simultaneous electrical impedance tomography

    Science.gov (United States)

    Han, Bing; Xu, Yanbin; Dong, Feng

    2017-09-01

    Multi-frequency electrical impedance tomography has been evolving from the frequency-sweep approach to the multi-frequency simultaneous measurement technique which can reduce measuring time and will be increasingly attractive for time-varying biological applications. The accuracy and stability of the current source are the key factors determining the quality of the image reconstruction. This article presents a field programmable gate array-based current source for a multi-frequency simultaneous electrical impedance tomography system. A novel current source circuit was realized by combining the classic current mirror based on the feedback amplifier AD844 with a differential topology. The optimal phase offsets of harmonic sinusoids were obtained through the crest factor analysis. The output characteristics of this current source were evaluated by simulation and actual measurement. The results include the following: (1) the output impedance was compared with one of the Howland pump circuit in simulation, showing comparable performance at low frequencies. However, the proposed current source makes lower demands for resistor tolerance but performs even better at high frequencies. (2) The output impedance in actual measurement below 200 kHz is above 1.3 MΩ and can reach 250 KΩ up to 1 MHz. (3) An experiment based on a biological RC model has been implemented. The mean error for the demodulated impedance amplitude and phase are 0.192% and 0.139°, respectively. Therefore, the proposed current source is wideband, biocompatible, and high precision, which demonstrates great potential to work as a sub-system in the multi-frequency electrical impedance tomography system.

  11. Comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, S.

    2009-07-01

    During the past two decades, active power filters have increasingly grown their popularity as a viable method for improving electric power quality. The main reasons for this have been the advent of fast self-commutating solid-state devices, the progression of digital technology and the improved sensor technology. Four-wire active power filters provide an efficient solution for improving the quality of supply in grounded three-phase systems or three-phase systems with neutral conductors, which are commonly used for powering residential, office and public buildings. Four-wire active power filters are applicable in compensating current harmonics, reactive power, neutral current and load phase imbalance.This thesis presents a comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters. The study includes two voltage source topologies and a current source topology with two different dc-link energy storage structures, which are compared on the basis of their filtering properties, filtering performance and efficiency. The obtained results are used for determining the suitability of current source technology for four-wire active power filtering and finding the most viable four-wire shunt active power filter topology. One commonly recognized disadvantage of the current source active power filter has always been the bulky dc-link inductor. To reduce the size of the dc-link inductor, an alternative dc-link structure for current source active power filters was introduced in the late 80's. The hybrid energy storage consists of both inductive and capacitive energy storage elements, two diodes and two controllable semiconductor switching devices. Since the capacitive element is used as a main storage unit, the inductance of the dc-link inductor can be considerably reduced. However, the original dc current control method proposed is not able to utilize the full potential of the hybrid energy storage and the inductance

  12. Temperature dependence of the current in Schottky-barrier source-gated transistors

    Science.gov (United States)

    Sporea, R. A.; Overy, M.; Shannon, J. M.; Silva, S. R. P.

    2015-05-01

    The temperature dependence of the drain current is an important parameter in thin-film transistors. In this paper, we propose that in source-gated transistors (SGTs), this temperature dependence can be controlled and tuned by varying the length of the source electrode. SGTs comprise a reverse biased potential barrier at the source which controls the current. As a result, a large activation energy for the drain current may be present which, although useful in specific temperature sensing applications, is in general deleterious in many circuit functions. With support from numerical simulations with Silvaco Atlas, we describe how increasing the length of the source electrode can be used to reduce the activation energy of SGT drain current, while maintaining the defining characteristics of SGTs: low saturation voltage, high output impedance in saturation, and tolerance to geometry variations. In this study, we apply the dual current injection modes to obtain drain currents with high and low activation energies and propose mechanisms for their exploitation in future large-area integrated circuit designs.

  13. Evaluation of Resonant Damping Techniques for Z-Source Current-Type Inverter

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Loh, Poh Chiang; Gajanayake, C.J.

    2008-01-01

    For the renewable energy sources whose outputs vary continuously, a Z-source current-type inverter has been proposed as a possible buck-boost alternative for grid-interfacing. With a unique X-shaped LC network connected between its dc power source and inverter topology, Z-source current......-type inverter is however expected to suffer from compounded resonant complications in addition to those associated with its second-order output filter. To improve its damping performance, this paper proposes the careful integration of Posicast or three-step compensators before the inverter pulse-width modulator...... for damping triggered resonant oscillations. In total, two compensators are needed for wave-shaping the inverter boost factor and modulation ratio, and they can conveniently be implemented using first-in first-out stacks and embedded timers of modern digital signal processors widely used in motion control...

  14. The high peak current polarized electron source of the Stanford Linear Collider

    International Nuclear Information System (INIS)

    Schultz, D.; Alley, R.; Aoyagi, H.; Clendenin, J.; Frisch, J.; Garden, C.; Hoyt, E.; Kirby, R.; Klaisner, L.; Kulikov, A.; Mulhollan, G.; Prescott, C.; Saez, P.; Tang, H.; Turner, J.; Woods, M.; Yeremian, D.; Zolotorev, M.

    1994-01-01

    The Stanford Linear Collider injector requires two 2 ns pulses of 4.5-5.5 x 10 10 electrons, separated by 61 ns at 120 Hz, from its source. Since 1992, these currents have been provided by a polarized electron source based on GaAs photocathodes. A beam polarization of 76±4% has been measured at the end of the 50 GeV linac. At low photocathode quantum efficiencies, and for excitation near threshold, the maximum current delivered by the source is constrained, not by the space charge limit of the gun, but by a ''charge limit'' of the photocathode. The charge limited current is proportional to the photocathode quantum efficiency, but the proportionality varies for different photocathode types. Experience with high polarization strained GaAs photocathodes on a test beamline and on the SLC is presented. (orig.)

  15. On the source material of magmas - with special reference to Nd isotopic ratios of igneous rocks

    International Nuclear Information System (INIS)

    Shuto, Kenji

    1980-01-01

    In 1973, the Sm-Nd method was first used for the measurement of the absolute age of igneous rocks and meteorites. Subsequently in the following years, the research works by means of the Nd isotopic ratio in igneous rocks have been made strenuously in order to reveal the chemistry of the source materials of magma giving rise to the igneous rocks and further the evolution process of mantle and earth's crust. The fundamental items for the Sm-Nd method are explained. Then, the research results more important in the above connection are given. Finally, the ideas by the author concerning the source materials of magma are presented from the data available on the Nd isotopes in meteorites and igneous rocks. The following matters are described: the fundamentals of Sm-Nd method, the Nd content in seawater, the negative correlation between Nd and Sr isotopic ratios in igneous rocks, magma source materials and Nd isotopes, and considerations on magma source materials. (J.P.N.)

  16. Inverted end-Hall-type low-energy high-current gaseous ion source

    International Nuclear Information System (INIS)

    Oks, E. M.; Vizir, A. V.; Shandrikov, M. V.; Yushkov, G. Yu.; Grishin, D. M.; Anders, A.; Baldwin, D. A.

    2008-01-01

    A novel approach to low-energy, high-current, gaseous ion beam generation was explored and an ion source based on this technique has been developed. The source utilizes a dc high-current (up to 20 A) gaseous discharge with electron injection into the region of ion generation. Compared to the conventional end-Hall ion source, the locations of the discharge anode and cathode are inverted: the cathode is placed inside the source and the anode outside, and correspondingly, the discharge current is in the opposite direction. The discharge operates in a diverging axial magnetic field, similar to the end-Hall source. Electron generation and injection is accomplished by using an additional arc discharge with a ''cold'' (filamentless) hollow cathode. Low plasma contamination is achieved by using a low discharge voltage (avoidance of sputtering), as well as by a special geometric configuration of the emitter discharge electrodes, thereby filtering (removing) the erosion products stemming from the emitter cathode. The device produces a dc ion flow with energy below 20 eV and current up to 2.5 A onto a collector of 500 cm 2 at 25 cm from the source edge, at a pressure ≥0.02 Pa and gas flow rate ≥14 SCCM. The ion energy spread is 2 to 3 eV (rms). The source is characterized by high reliability, low maintenance, and long lifetime. The beam contains less than 0.1% of metallic ions. The specific electric energy consumption is 400 eV per ion registered at the collector. The source operates with noble gases, nitrogen, oxygen, and hydrocarbons. Utilizing biasing, it can be used for plasma sputtering, etching, and other ion technologies

  17. Solar quiet day ionospheric source current in the West African region

    OpenAIRE

    Obiekezie, Theresa N.; Okeke, Francisca N.

    2012-01-01

    The Solar Quiet (Sq) day source current were calculated using the magnetic data obtained from a chain of 10 magnetotelluric stations installed in the African sector during the French participation in the International Equatorial Electrojet Year (IEEY) experiment in Africa. The components of geomagnetic field recorded at the stations from January–December in 1993 during the experiment were separated into the source and (induced) components of Sq using Spherical Harmonics Analysis (SHA) method....

  18. Polyatomic ions from a high current ion implanter driven by a liquid metal ion source

    Science.gov (United States)

    Pilz, W.; Laufer, P.; Tajmar, M.; Böttger, R.; Bischoff, L.

    2017-12-01

    High current liquid metal ion sources are well known and found their first application as field emission electric propulsion thrusters in space technology. The aim of this work is the adaption of such kind of sources in broad ion beam technology. Surface patterning based on self-organized nano-structures on, e.g., semiconductor materials formed by heavy mono- or polyatomic ion irradiation from liquid metal (alloy) ion sources (LMAISs) is a very promising technique. LMAISs are nearly the only type of sources delivering polyatomic ions from about half of the periodic table elements. To overcome the lack of only very small treated areas by applying a focused ion beam equipped with such sources, the technology taken from space propulsion systems was transferred into a large single-end ion implanter. The main component is an ion beam injector based on high current LMAISs combined with suited ion optics allocating ion currents in the μA range in a nearly parallel beam of a few mm in diameter. Different types of LMAIS (needle, porous emitter, and capillary) are presented and characterized. The ion beam injector design is specified as well as the implementation of this module into a 200 kV high current ion implanter operating at the HZDR Ion Beam Center. Finally, the obtained results of large area surface modification of Ge using polyatomic Bi2+ ions at room temperature from a GaBi capillary LMAIS will be presented and discussed.

  19. Hydrate studies of northern Cascadia margin off Vancouver Island : a reference source

    Energy Technology Data Exchange (ETDEWEB)

    Hyndman, R. [Natural Resources Canada, Sidney, BC (Canada). Geological Survey of Canada, Pacific Geoscience Centre]|[Victoria Univ., BC (Canada). School of Earth and Ocean Sciences; Riedel, M. [McGill Univ., Montreal, PQ (Canada). Dept. of Earth and Planetary Sciences; Spence, G.D. [Victoria Univ., BC (Canada). School of Earth and Ocean Sciences

    2008-07-01

    Extensive geophysical studies have been conducted to determine the occurrence, distribution, and concentration of gas hydrate in the Cascadia subduction zone off western Canada. In this paper, the authors compiled a comprehensive reference list of studies involving marine natural gas hydrate surveys and studies on the northern Cascadia margin. The reference categories included general reviews; regional tectonic framework for northern Cascadia hydrate; prism sediment thickening, fluid expulsion and hydrate formation; and, seismic surveys. This paper first addressed the local tectonics and the sedimentary accretionary prism in which the hydrate forms, followed by a description of the geophysical and geological surveys that have been conducted. The surveys included a wide range of seismic surveys such as multichannel, ocean-bottom, high-resolution single channel and very high resolution deep towed surveys. Heat flow, electrical sounding, seafloor compliance, sediment coring, and mapping gas plumes from the seafloor were among the other geophysical studies listed in this paper. The conclusions that have resulted from this work in terms of distribution, concentrations and amounts of hydrate were presented along with a discussion on the process of hydrate formation and dissociation. 96 refs., 3 figs.

  20. Current status of securing Category 1 and 2 radioactive sources in Taiwan

    Energy Technology Data Exchange (ETDEWEB)

    Cheng, Y-F.; Tsai, C-H. [Atomic Energy Council of Executive Yuan of Taiwan (China)

    2014-07-01

    For enhancing safe and secure management of Category 1 and 2 radioactive sources against theft or unauthorized removal, AEC (Atomic Energy Council) of Taiwan have been regulating the import/export of the sources ever since 2005, in compliance with the IAEA's (International Atomic Energy Agency) 'Guidance on the Import and Export of Radioactive Sources'. Furthermore in consulting the IAEA Nuclear Security Series No.11 report, administrative regulations on the program of securing the sources have been embodied into AECL's regulatory system since 2012, for the purpose of enforcing medical and non-medical licensees and industrial radiographers to establish their own radioactive source security programs. Regulations require that security functions such as access control, detection, delay, response and communication and security management measures are to be implemented within the programs. This paper is to introduce the current status in implementing the security control measures in Taiwan. (author)

  1. Identification of radiation induced dark current sources in pinned photodiode CMOS image sensors

    International Nuclear Information System (INIS)

    Goiffon, V.; Virmontois, C.; Magnan, P.; Cervantes, P.; Place, S.; Estribeau, M.; Martin-Gonthier, P.; Gaillardin, M.; Girard, S.; Paillet, P.

    2012-01-01

    This paper presents an investigation of Total Ionizing Dose (TID) induced dark current sources in Pinned Photodiodes (PPD) CMOS Image Sensors based on pixel design variations. The influence of several layout parameters is studied. Only one parameter is changed at a time enabling the direct evaluation of its contribution to the observed device degradation. By this approach, the origin of radiation induced dark current in PPD is localized on the pixel layout. The PPD peripheral shallow trench isolation does not seem to play a role in the degradation. The PPD area and a transfer gate contribution independent of the pixel dimensions appear to be the main sources of the TID induced dark current increase. This study also demonstrates that applying a negative voltage on the transfer gate during integration strongly reduces the radiation induced dark current. (authors)

  2. Current Harmonics Compensation in Microgrids Exploiting the Power Electronics Interfaces of Renewable Energy Sources

    Directory of Open Access Journals (Sweden)

    Ioannis Bouloumpasis

    2015-03-01

    Full Text Available This work presents a method of current harmonic reduction in a distorted distribution system. In order to evaluate the proposed method a grid with high-order current harmonics is assumed. The reduction of current distortion is feasible due to the pulse modulation of an active filter, which consists of a buck-boost converter connected back-to-back to a polarity swapping inverter. For a practical application, this system would be the power electronic interface of a Renewable Energy Source (RES and therefore it changes a source of harmonics to a damping harmonics system. Using the proposed method, the current Total Harmonic Distortion (THD of the grid is reduced below the acceptable limits and thus the general power quality of the system is improved. Simulations in the MATLAB/SIMULINK platform and experiments have been performed in order to verify the effectiveness of the proposed method.

  3. Recent advances in high current vacuum arc ion sources for heavy ion fusion

    CERN Document Server

    Qi Nian Sheng; Prasad, R R; Krishnan, M S; Anders, A; Kwan, J; Brown, I

    2001-01-01

    For a heavy ion fusion induction linac driver, a source of heavy ions with charge states 1+-3+, approx 0.5 A current beams, approx 20 mu s pulse widths and approx 10 Hz repetition rates is required. Thermionic sources have been the workhorse for the Heavy Ion Fusion (HIF) program to date, but suffer from heating problems for large areas and contamination. They are limited to low (contact) ionization potential elements and offer relatively low ion fluxes with a charge state limited to 1+. Gas injection sources suffer from partial ionization and deleterious neutral gas effects. The above shortcomings of the thermionic ion sources can be overcome by a vacuum arc ion source. The vacuum arc ion source is a good candidate for HIF applications. It is capable of providing ions of various elements and different charge states in short and long pulse bursts and high beam current density. Under a Phase-I STTR from DOE, the feasibility of the vacuum arc ion source for the HIF applications was investigated. We have modifie...

  4. Estimation of parameters for the electrostatic discharge current equation with real human discharge events reference using genetic algorithms

    International Nuclear Information System (INIS)

    Katsivelis, P S; Gonos, I F; Stathopulos, I A

    2010-01-01

    Thorough study of the electrostatic discharge (ESD) current equation shows that it may be different from the equation proposed in the IEC 61000-4-2 Standard. This problem is dealt with in this paper. Using a 2.5 GHz digital oscilloscope and a 50 Ω Pellegrini target as the measuring system, and a dc power supply to provide a charging voltage of 2 kVdc, a series of measurements were performed, so real human-to-metal ESD current waveforms were recorded. Treating the average waveform as a reference, a genetic algorithm (GA) was applied to the equation of the IEC 61000-4-2 Standard for the ESD current, in order to achieve its best fitting to the data set. Four different error norms were used for the GA applications. The best result of the applications of each of them was saved and compared to the others. Thus, a very satisfactory modification of the Standard's equation is presented, which is closer to the real ESD current waveform

  5. Studies in High Current Density Ion Sources for Heavy Ion Fusion Applications

    International Nuclear Information System (INIS)

    Chacon-Golcher, E.

    2002-01-01

    This dissertation develops diverse research on small (diameter ∼ few mm), high current density (J ∼ several tens of mA/cm 2 ) heavy ion sources. The research has been developed in the context of a programmatic interest within the Heavy Ion Fusion (HIF) Program to explore alternative architectures in the beam injection systems that use the merging of small, bright beams. An ion gun was designed and built for these experiments. Results of average current density yield ( ) at different operating conditions are presented for K + and Cs + contact ionization sources and potassium aluminum silicate sources. Maximum values for a K + beam of ∼90 mA/cm 2 were observed in 2.3 (micro)s pulses. Measurements of beam intensity profiles and emittances are included. Measurements of neutral particle desorption are presented at different operating conditions which lead to a better understanding of the underlying atomic diffusion processes that determine the lifetime of the emitter. Estimates of diffusion times consistent with measurements are presented, as well as estimates of maximum repetition rates achievable. Diverse studies performed on the composition and preparation of alkali aluminosilicate ion sources are also presented. In addition, this work includes preliminary work carried out exploring the viability of an argon plasma ion source and a bismuth metal vapor vacuum arc (MEVVA) ion source. For the former ion source, fast rise-times (∼ 1 (micro)s), high current densities (∼ 100 mA/cm 2 ) and low operating pressures ( e psilon) n (le) 0.006 π mm · mrad) although measured currents differed from the desired ones (I ∼ 5mA) by about a factor of 10

  6. Studies in High Current Density Ion Sources for Heavy Ion Fusion Applications

    Energy Technology Data Exchange (ETDEWEB)

    Chacon-Golcher, Edwin [Univ. of California, Berkeley, CA (United States)

    2002-06-01

    This dissertation develops diverse research on small (diameter ~ few mm), high current density (J ~ several tens of mA/cm2) heavy ion sources. The research has been developed in the context of a programmatic interest within the Heavy Ion Fusion (HIF) Program to explore alternative architectures in the beam injection systems that use the merging of small, bright beams. An ion gun was designed and built for these experiments. Results of average current density yield () at different operating conditions are presented for K+ and Cs+ contact ionization sources and potassium aluminum silicate sources. Maximum values for a K+ beam of ~90 mA/cm2 were observed in 2.3 μs pulses. Measurements of beam intensity profiles and emittances are included. Measurements of neutral particle desorption are presented at different operating conditions which lead to a better understanding of the underlying atomic diffusion processes that determine the lifetime of the emitter. Estimates of diffusion times consistent with measurements are presented, as well as estimates of maximum repetition rates achievable. Diverse studies performed on the composition and preparation of alkali aluminosilicate ion sources are also presented. In addition, this work includes preliminary work carried out exploring the viability of an argon plasma ion source and a bismuth metal vapor vacuum arc (MEVVA) ion source. For the former ion source, fast rise-times (~ 1 μs), high current densities (~ 100 mA/cm+) and low operating pressures (< 2 mtorr) were verified. For the latter, high but acceptable levels of beam emittance were measured (εn ≤ 0.006 π· mm · mrad) although measured currents differed from the desired ones (I ~ 5mA) by about a factor of 10.

  7. NAVAIR Portable Source Initiative (NPSI) Standard for Material Properties Reference Database (MPRD) V2.2

    Science.gov (United States)

    2012-09-26

    of a material to conduct electricity . p-electrical_resisitivity electrical resistivity electrical ohm-m The property of a material...that resists the flow of electrical current. p-magnetic_susceptibility magnetic susceptibility electrical The degree to which a...enumeration Zr enumeration Nb enumeration Mo enumeration Tc enumeration Ru enumeration Rh enumeration Pd enumeration Ag enumeration

  8. Stator Current Harmonic Reduction in a Novel Half Quasi-Z-Source Wind Power Generation System

    Directory of Open Access Journals (Sweden)

    Shoudao Huang

    2016-09-01

    Full Text Available The generator stator current gets distorted with unacceptable levels of total harmonic distortion (THD because impedance-source wind power generation systems use three-phase diode rectifiers. The stator current harmonics will cause increasing losses and torque ripple, which reduce the efficiency and stability of the system. This paper proposes a novel half quasi-Z-source inverter (H-qZSI for grid-connected wind power generation systems, which can reduce the generator stator current harmonics a great deal. When H-qZSI operates in the shoot-through zero state, the derivative of the generator stator current is only determined by the instantaneous value of the generator stator voltage, so the nonlinear relationship between generator stator current and stator voltage is improved compared with the traditional impedance-source inverter. Theoretically, it is indicated that the stator current harmonics can be reduced effectively by means of the proposed H-qZSI. Finally, simulation and experimental results are given to verify the theoretical analysis.

  9. Variability of extragalactic sources: its contribution to the link between ICRF and the future Gaia Celestial Reference Frame

    Science.gov (United States)

    Taris, F.; Damljanovic, G.; Andrei, A.; Souchay, J.; Klotz, A.; Vachier, F.

    2018-03-01

    Context. The first release of the Gaia catalog is available since 14 September 2016. It is a first step in the realization of the future Gaia reference frame. This reference frame will be materialized by the optical positions of the sources and will be compared with and linked to the International Celestial Reference Frame, materialized by the radio position of extragalactic sources. Aim. As in the radio domain, it can be reasonably postulated that quasar optical flux variations can alert us to potential changes in the source structure. These changes could have important implications for the position of the target photocenters (together with the evolution in time of these centers) and in parallel have consequences for the link of the reference systems. Methods: A set of nine optical telescopes was used to monitor the magnitude variations, often at the same time as Gaia, thanks to the Gaia Observation Forecast Tool. The Allan variances, which are statistical tools widely used in the atomic time and frequency community, are introduced. Results: This work describes the magnitude variations of 47 targets that are suitable for the link between reference systems. We also report on some implications for the Gaia catalog. For 95% of the observed targets, new information about their variability is reported. In the case of some targets that are well observed by the TAROT telescopes, the Allan time variance shows that the longest averaging period of the magnitudes is in the range 20-70 d. The observation period by Gaia for a single target largely exceeds these values, which might be a problem when the magnitude variations exhibit flicker or random walk noises. Preliminary computations show that if the coordinates of the targets studied in this paper were affected by a white-phase noise with a formal uncertainty of about 1 mas (due to astrophysical processes that are put in evidence by the magnitude variations of the sources), it would affect the precision of the link at the

  10. Experiences on current national income measures with reference to environmental and natural resources; Esperienze e proposte relative alla correzione in senso ambientale delle misure del reddito nazionale

    Energy Technology Data Exchange (ETDEWEB)

    Franzese, R; Gaudioso, D [ENEA, Casaccia (Italy). Dipt. Ambiente

    1995-06-01

    The environment provides both a source of goods and services and a `sink` for residues of the production and consumption processes. This is not reflected into conventional estimate of GDP (gross domestic product), the most commonly used measure of aggregate income. The purpose of this paper is to explore whether environmentally-adjusted national income measure can be derived. In the first part, the authors discuss both the shortcomings of the current national income measures, with reference to environmental and natural resources, and the debate on this issues; then they analyse the existing experiences to provide environmentally-adjusted indicators of national accounts. In the second part, the authors present an evaluation of the costs of environmental degradation in Italy in the period 1988-1990, based on the methodologies adopted in a pilot study carried out by UNSO (United Nations Statistical Office) and the World Bank for Mexico.

  11. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  12. Current Status of Cadaver Sources in Turkey and a Wake-Up Call for Turkish Anatomists

    Science.gov (United States)

    Gürses, Ilke Ali; Coskun, Osman; Öztürk, Adnan

    2018-01-01

    Persisting difficulties in body procurement in Turkey led to the acquisition of donated, unclaimed, autopsied, and imported bodies regulated under current legislature. Yet, no study had investigated the extent of the on-going cadaver problem. This study was aimed to outline cadaver sources in anatomy departments and their effectiveness by means of…

  13. LED deep UV source for charge management of gravitational reference sensors

    International Nuclear Information System (INIS)

    Sun Kexun; Allard, Brett; Buchman, Saps; Williams, Scott; Byer, Robert L

    2006-01-01

    Proof mass electrical charge management is an important functionality for the ST-7-LTP technology demonstration flight and for LISA. Photoemission for charge control is accomplished by using deep ultraviolet (UV) light to excite photoelectron emission from an Au alloy. The conventional UV source is a mercury vapour lamp. We propose and demonstrate charge management using a deep UV light emitting diode (LED) source. We have acquired selected AlGaN UV LEDs, characterized their performance and successfully used them to realize charge management. The UV LEDs emit at a 257 nm central wavelength with a bandwidth of ∼12 nm. The UV power for a free-space LED is ∼120 μW, and after fibre coupling is ∼16 μW, more than sufficient for LISA applications. We have directly observed the LED UV light-induced photocurrent response from an Au photocathode and an Au-coated GRS/ST-7 proof mass. We demonstrated fast switching of UV LEDs and associated fast changes in photocurrent. This allows modulation and continuous discharge to meet stringent LISA disturbance reduction requirements. We propose and demonstrate AC charge management outside the gravitational wave signal band. Further, the megahertz bandwidth for UV LED switching allows for up to six orders of magnitude dynamic power range and a number of novel modes of operations. The UV LED based charge management system offers the advantages of small-size, lightweight, fibre-coupled operation with very low power consumption

  14. Design and validation of an open-source library of dynamic reference frames for research and education in optical tracking.

    Science.gov (United States)

    Brown, Alisa; Uneri, Ali; Silva, Tharindu De; Manbachi, Amir; Siewerdsen, Jeffrey H

    2018-04-01

    Dynamic reference frames (DRFs) are a common component of modern surgical tracking systems; however, the limited number of commercially available DRFs poses a constraint in developing systems, especially for research and education. This work presents the design and validation of a large, open-source library of DRFs compatible with passive, single-face tracking systems, such as Polaris stereoscopic infrared trackers (NDI, Waterloo, Ontario). An algorithm was developed to create new DRF designs consistent with intra- and intertool design constraints and convert to computer-aided design (CAD) files suitable for three-dimensional printing. A library of 10 such groups, each with 6 to 10 DRFs, was produced and tracking performance was validated in comparison to a standard commercially available reference, including pivot calibration, fiducial registration error (FRE), and target registration error (TRE). Pivot tests showed calibration error [Formula: see text], indistinguishable from the reference. FRE was [Formula: see text], and TRE in a CT head phantom was [Formula: see text], both equivalent to the reference. The library of DRFs offers a useful resource for surgical navigation research and could be extended to other tracking systems and alternative design constraints.

  15. Current State and Future Perspectives of Energy Sources for Totally Implantable Cardiac Devices.

    Science.gov (United States)

    Bleszynski, Peter A; Luc, Jessica G Y; Schade, Peter; PhilLips, Steven J; Tchantchaleishvili, Vakhtang

    There is a large population of patients with end-stage congestive heart failure who cannot be treated by means of conventional cardiac surgery, cardiac transplantation, or chronic catecholamine infusions. Implantable cardiac devices, many designated as destination therapy, have revolutionized patient care and outcomes, although infection and complications related to external power sources or routine battery exchange remain a substantial risk. Complications from repeat battery replacement, power failure, and infections ultimately endanger the original objectives of implantable biomedical device therapy - eliminating the intended patient autonomy, affecting patient quality of life and survival. We sought to review the limitations of current cardiac biomedical device energy sources and discuss the current state and trends of future potential energy sources in pursuit of a lifelong fully implantable biomedical device.

  16. Current source converter based D-STATCOM for voltage sag mitigation

    Directory of Open Access Journals (Sweden)

    Singh Moirangthem Deben

    2015-01-01

    Full Text Available This paper presents a novel method of realizing one of the custom power controllers, the distribution static synchronous compensator (D-STATCOM using current source converter (CSC topology. Almost all the custom power controllers such as dynamic voltage restorer (DVR, unified power quality conditioner (UPQC including D-STATCOM are generally designed and implemented by using voltage source converters (VSC and not much research publications with CSC based approach has been reported over the last one decade. Since the D-STATCOM is a current injection device, its performance can be improved when realized by a current-source converter which can generate a controllable current directly at its output terminals and offers many advantageous features. In this paper, an attempt has been made to study the performance of a CSC based D-STATCOM suitable for use in the power distribution system in order to mitigate voltage sag and improve power quality. The proposed model uses a three leg CSC whose switching strategy is based on sinusoidal pulse width modulation (SPWM. The model has been simulated in the Matlab/Simulink environment. The results of the simulation runs under steady state and dynamic load perturbation provide excellent voltage and current waveforms that support the justification of the proposed model.

  17. An image-based skeletal dosimetry model for the ICRP reference newborn-internal electron sources

    International Nuclear Information System (INIS)

    Pafundi, Deanna; Lee, Choonsik; Bolch, Wesley; Rajon, Didier; Jokisch, Derek

    2010-01-01

    In this study, a comprehensive electron dosimetry model of newborn skeletal tissues is presented. The model is constructed using the University of Florida newborn hybrid phantom of Lee et al (2007 Phys. Med. Biol. 52 3309-33), the newborn skeletal tissue model of Pafundi et al (2009 Phys. Med. Biol. 54 4497-531) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow (surrogate tissue for hematopoietic stem cells), shallow marrow (surrogate tissue for osteoprogenitor cells) and unossified cartilage (surrogate tissue for chondrocytes). Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following source tissues: active marrow, trabecular bone (surfaces and volumes), cortical bone (surfaces and volumes) and cartilage. Transport results are reported as specific absorbed fractions according to the MIRD schema and are given as skeletal-averaged values in the paper with bone-specific values reported in both tabular and graphic format as electronic annexes (supplementary data). The method utilized in this work uniquely includes (1) explicit accounting for the finite size and shape of newborn ossification centers (spongiosa regions), (2) explicit accounting for active and shallow marrow dose from electron emissions in cortical bone as well as sites of unossified cartilage, (3) proper accounting of the distribution of trabecular and cortical volumes and surfaces in the newborn skeleton when considering mineral bone sources and (4) explicit consideration of the marrow cellularity changes for active marrow self-irradiation as applicable to radionuclide therapy of diseased marrow in the newborn child.

  18. An image-based skeletal dosimetry model for the ICRP reference newborn-internal electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Pafundi, Deanna; Lee, Choonsik; Bolch, Wesley [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL (United States); Rajon, Didier [Department of Neurosurgery, University of Florida, Gainesville, FL (United States); Jokisch, Derek [Department of Physics and Astronomy, Francis Marion University, Florence, SC (United States)], E-mail: wbolch@ufl.edu

    2010-04-07

    In this study, a comprehensive electron dosimetry model of newborn skeletal tissues is presented. The model is constructed using the University of Florida newborn hybrid phantom of Lee et al (2007 Phys. Med. Biol. 52 3309-33), the newborn skeletal tissue model of Pafundi et al (2009 Phys. Med. Biol. 54 4497-531) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow (surrogate tissue for hematopoietic stem cells), shallow marrow (surrogate tissue for osteoprogenitor cells) and unossified cartilage (surrogate tissue for chondrocytes). Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following source tissues: active marrow, trabecular bone (surfaces and volumes), cortical bone (surfaces and volumes) and cartilage. Transport results are reported as specific absorbed fractions according to the MIRD schema and are given as skeletal-averaged values in the paper with bone-specific values reported in both tabular and graphic format as electronic annexes (supplementary data). The method utilized in this work uniquely includes (1) explicit accounting for the finite size and shape of newborn ossification centers (spongiosa regions), (2) explicit accounting for active and shallow marrow dose from electron emissions in cortical bone as well as sites of unossified cartilage, (3) proper accounting of the distribution of trabecular and cortical volumes and surfaces in the newborn skeleton when considering mineral bone sources and (4) explicit consideration of the marrow cellularity changes for active marrow self-irradiation as applicable to radionuclide therapy of diseased marrow in the newborn child.

  19. Quasi-steady state, low current behaviour of a magnetized coaxial plasma source

    International Nuclear Information System (INIS)

    Gray, Travis K; Mayo, Robert M; Bourham, Mohamed A

    2005-01-01

    The Coaxial Plasma Source-1 facility (Mayo R M et al 1995 Plasma Sources Sci. Technol. 4 47) was modified from a short pulse, high current (SPHC) pulse forming network (PFN) with very low inductance (∼200 nH) to a large inductance ladder circuit. This modification allows for a longer, flat top gun current pulse that eliminates the under-damped, sinusoidal behaviour of the gun current with consequent interruptions in plasma parameters. The new PFN was designed to produce a current waveform for a much longer period (∼1 ms). As a consequence of increasing the pulse length, the magnitude of the gun current was reduced as no additional energy storage was added to the PFN. The characterization of the electrical and plasma behaviour of the experiment operated with the long pulse, low current (LPLC) PFN is presented. The gun currents produced by the LPLC PFN are approximately one-fifth in magnitude of the gun currents produced by the SPHC PFN. Axial plasma parameters were measured near the muzzle of the plasma source, and electron densities were found to range from 1 x 10 19 m -3 to 7 x 10 19 m -3 depending upon the axial location. These values are approximately 1-2 orders of magnitude less than the electron densities produced by the SPHC PFN at the same locations. Electron temperatures range from 30 to 60 eV at these locations and are very similar to those produced by the SPHC PFN. A resistive MHD model was applied as an order estimate of the plasma resistivity and demonstrates reasonable agreement with measured values of the magnetized coaxial gun resistance

  20. Quasi-steady state, low current behaviour of a magnetized coaxial plasma source

    Energy Technology Data Exchange (ETDEWEB)

    Gray, Travis K; Mayo, Robert M; Bourham, Mohamed A [Department of Nuclear Engineering, North Carolina State University, Raleigh, NC 27695-7909 (United States)

    2005-11-15

    The Coaxial Plasma Source-1 facility (Mayo R M et al 1995 Plasma Sources Sci. Technol. 4 47) was modified from a short pulse, high current (SPHC) pulse forming network (PFN) with very low inductance ({approx}200 nH) to a large inductance ladder circuit. This modification allows for a longer, flat top gun current pulse that eliminates the under-damped, sinusoidal behaviour of the gun current with consequent interruptions in plasma parameters. The new PFN was designed to produce a current waveform for a much longer period ({approx}1 ms). As a consequence of increasing the pulse length, the magnitude of the gun current was reduced as no additional energy storage was added to the PFN. The characterization of the electrical and plasma behaviour of the experiment operated with the long pulse, low current (LPLC) PFN is presented. The gun currents produced by the LPLC PFN are approximately one-fifth in magnitude of the gun currents produced by the SPHC PFN. Axial plasma parameters were measured near the muzzle of the plasma source, and electron densities were found to range from 1 x 10{sup 19} m{sup -3} to 7 x 10{sup 19} m{sup -3} depending upon the axial location. These values are approximately 1-2 orders of magnitude less than the electron densities produced by the SPHC PFN at the same locations. Electron temperatures range from 30 to 60 eV at these locations and are very similar to those produced by the SPHC PFN. A resistive MHD model was applied as an order estimate of the plasma resistivity and demonstrates reasonable agreement with measured values of the magnetized coaxial gun resistance.

  1. Transcranial direct current stimulation over the parietal cortex alters bias in item and source memory tasks.

    Science.gov (United States)

    Pergolizzi, Denise; Chua, Elizabeth F

    2016-10-01

    Neuroimaging data have shown that activity in the lateral posterior parietal cortex (PPC) correlates with item recognition and source recollection, but there is considerable debate about its specific contributions. Performance on both item and source memory tasks were compared between participants who were given bilateral transcranial direct current stimulation (tDCS) over the parietal cortex to those given prefrontal or sham tDCS. The parietal tDCS group, but not the prefrontal group, showed decreased false recognition, and less bias in item and source discrimination tasks compared to sham stimulation. These results are consistent with a causal role of the PPC in item and source memory retrieval, likely based on attentional and decision-making biases. Copyright © 2016 Elsevier Inc. All rights reserved.

  2. Experimental research on specific activity of 24Na using Chinese reference man phantom irradiated by 252Cf neutrons source

    International Nuclear Information System (INIS)

    Wang Yuexing; Yang Yifang; Lu Yongjie; Zhang Jianguo; Xing Hongchuan

    2011-01-01

    Objective: To investigate the specific activity of '2 4 Na per unit neutron fluence, A B/Φ ,in blood produced for Chinese reference man irradiated by 252 Cf neutron source,and to analyze the effects of scattering neutrons from ground,wall,and ceiling in irradiation site on it.Methods: A 252 Cf neutron source of 3×10 8 n/s and the anthropomorphic phantom were used for experiments. The phantom was made from 4 mm thick of outer covering by perspex and the liquid tissue-equivalent substitute in it. The data of phantom dimensions fit into Chinese reference man.The weight ratios of H, N, O and C in substitute equal from source to long axis of phantom were 1.1, 2.1, 3.1 and 4.1 m, respectively. Both the neutron source and the position of xiphisternum of the phantom were 1.6 m above the floor. Results: The average specific activity of 24 Na per unit neutron fluence was related to the irradiation-distances, d, and its maximum value, A B/ΦM , deduced by experimental data was about 1.85×10 -7 Bq·cm 2 ·g -1 . Conclusions: The A B/ΦM corresponds to that of phantom irradiated by plane-parallel beams, and the value is about more 3% than that by BOMAB phantom reported in literature. It has shown that floor-(wall-)scattered neutrons in irradiation site have significant contribution to the specific activity of 24 Na, but they contributed relatively little to the induced neutron doses. Consequently,using the specific activity of 24 Na for assessing accidental neutron doses received by an individual, the contribution of scattered neutrons in accident site will lead dose to be overestimated, and need to be correct. (authors)

  3. Neutron generator for BNCT based on high current ECR ion source with gyrotron plasma heating.

    Science.gov (United States)

    Skalyga, V; Izotov, I; Golubev, S; Razin, S; Sidorov, A; Maslennikova, A; Volovecky, A; Kalvas, T; Koivisto, H; Tarvainen, O

    2015-12-01

    BNCT development nowadays is constrained by a progress in neutron sources design. Creation of a cheap and compact intense neutron source would significantly simplify trial treatments avoiding use of expensive and complicated nuclear reactors and accelerators. D-D or D-T neutron generator is one of alternative types of such sources for. A so-called high current quasi-gasdynamic ECR ion source with plasma heating by millimeter wave gyrotron radiation is suggested to be used in a scheme of D-D neutron generator in the present work. Ion source of that type was developed in the Institute of Applied Physics of Russian Academy of Sciences (Nizhny Novgorod, Russia). It can produce deuteron ion beams with current density up to 700-800 mA/cm(2). Generation of the neutron flux with density at the level of 7-8·10(10) s(-1) cm(-2) at the target surface could be obtained in case of TiD2 target bombardment with deuteron beam accelerated to 100 keV. Estimations show that it is enough for formation of epithermal neutron flux with density higher than 10(9) s(-1) cm(-2) suitable for BNCT. Important advantage of described approach is absence of Tritium in the scheme. First experiments performed in pulsed regime with 300 mA, 45 kV deuteron beam directed to D2O target demonstrated 10(9) s(-1) neutron flux. This value corresponds to theoretical estimations and proofs prospects of neutron generator development based on high current quasi-gasdynamic ECR ion source. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Impurities, temperature, and density in a miniature electrostatic plasma and current source

    International Nuclear Information System (INIS)

    Den Hartog, D.J.; Craig, D.J.; Fiksel, G.; Sarff, J.S.

    1996-10-01

    We have spectroscopically investigated the Sterling Scientific miniature electrostatic plasma source-a plasma gun. This gun is a clean source of high density (10 19 - 10 20 m -3 ), low temperature (5 - 15 eV) plasma. A key result of our investigation is that molybdenum from the gun electrodes is largely trapped in the internal gun discharge; only a small amount escapes in the plasma flowing out of the gun. In addition, the gun plasma parameters actually improve (even lower impurity contamination and higher ion temperature) when up to 1 kA of electron current is extracted from the gun via the application of an external bias. This improvement occurs because the internal gun anode no longer acts as the current return for the internal gun discharge. The gun plasma is a virtual plasma electrode capable of sourcing an electron emission current density of 1 kA/cm 2 . The high emission current, small size (3 - 4 cm diameter), and low impurity generation make this gun attractive for a variety of fusion and plasma technology applications

  5. A high current metal vapour vacuum arc ion source for ion implantation studies

    International Nuclear Information System (INIS)

    Evans, P.J.; Noorman, J.T.; Watt, G.C.; Cohen, D.D.; Bailey, G.M.

    1989-01-01

    The main features of the metal vapour vacuum arc(MEVA) as an ion source are presented. The technology utilizes the plasma production capabilities of a vacuum arc cathode. Some of the ions produced in this discharge flow through the anode and the 3 extraction grids to form an extracted ion beam. The high beam current and the potential for generating broad beams, make this technology suitable for implantation of large surface areas. The composition of the vacuum arc cathode determines the particular ions obtained from the MEVA source. 3 refs., 1 tab., 2 figs

  6. A simplified approach to estimating reference source terms for LWR designs

    International Nuclear Information System (INIS)

    1999-12-01

    systems. The publication of this IAEA technical document represents the conclusion of a task, initiated in 1996, devoted to the estimation of the radioactive source term in nuclear reactors. It focuses mainly on light water reactors (LWRs)

  7. Development of the neutron reference calibration field using a {sup 252}Cf standard source surrounded with PMMA moderators

    Energy Technology Data Exchange (ETDEWEB)

    Yoshida, T.; Kanai, K.; Tsujimura, N. [Japan Nuclear Cycle Development Institute, Ibaraki-ken (Japan)

    2002-07-01

    The authors developed the neutron reference calibration fields using a {sup 252} Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the {sup 252} Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO{sub 2}-UO{sub 2} mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments.

  8. Development of the neutron reference calibration field using a 252Cf standard source surrounded with PMMA moderators

    International Nuclear Information System (INIS)

    Yoshida, T.; Kanai, K.; Tsujimura, N.

    2002-01-01

    The authors developed the neutron reference calibration fields using a 252 Cf standard source surrounded with PMMA moderators at the Japan Nuclear Cycle Development (JNC), Tokai Works. The moderators are co-axial, hollow cylinders made of lead-contained PMMA with a thickness of 13.5, 35.0, 59.5 and 77.0mm, and the 252 Cf source is guided to the geometric center of moderators by the pneumatic system. These fields can provide the moderated neutron spectra very similar to those encountered around the globe-boxes of the fabrication process of MOX (PuO 2 -UO 2 mixed oxide) fuel. The neutron energy spectrum at the reference calibration point was evaluated from the calculations by MCNP4B and the measurements by the INS-type Bonner multi-sphere spectrometer and the hydrogen-filled proportional counters. The calculated neutron spectra were in good agreements with the measured ones. These fields were characterized in terms of the neutron fluence rate, spectral composition and ambient dose equivalent rate, and have served for the response-characterization of various neutron survey instruments

  9. Partitioning and transmutation. Current developments - 2007. A report from the Swedish reference group on P-T-research

    International Nuclear Information System (INIS)

    Ahlstroem, Per-Eric; Blomgren, Jan; Eriksson, Marcus; Seltborg, Per; Wallenius, Jan; Westlen, Daniel

    2007-06-01

    This report is written on behalf of the Swedish reference group for research on partitioning and transmutation. The reference group has been assembled by SKB and its members represent the teams that are active in this field at Swedish universities. The present report summarises the progress in the field through the years 2004-2006. A prerequisite for transmutation by irradiation with neutrons is that the nuclides to be transmuted are separated (partitioned) from the other nuclides in the spent fuel. In particular the remaining uranium must be taken away unless you want to produce more plutonium and other transuranium elements. Separation of the various elements can at least in principle be achieved by mechanical and chemical processes. Currently there exist some large scale facilities for separation of uranium and plutonium from the spent fuel-reprocessing plants. These can, however, not separate the minor actinides - neptunium, americium and curium - from the high level waste that goes to a repository. Plutonium constitutes about 90% of the transuranium elements in fuel from light water reactors. The objective of current research on partitioning is to find and develop processes suitable for separation of the heavier actinides (and possibly some long-lived fission products) on an industrial scale. The objective of current research on transmutation is to define, investigate and develop facilities that may be suitable for transmutation of the aforementioned long-lived radionuclides. The research on partitioning has made important progress in recent years. In some cases one has succeeded to separate americium and curium. Many challenges remain however. Within hydrochemistry one has achieved sufficiently good distribution and separation factors. The focus turns now towards development of an operating process. The search for ligands that give sufficiently good extraction and separation will continue but with less intensity. The emphasis will rather be on improving

  10. Partitioning and transmutation. Current developments - 2007. A report from the Swedish reference group on P-T-research

    Energy Technology Data Exchange (ETDEWEB)

    Ahlstroem, Per-Eric (ed.) [Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden); Blomgren, Jan [Uppsala Univ. (Sweden). Dept. of Neutron Research; Ekberg, Christian; Englund, Sofie; Fermvik, Anna; Liljenzin, Jan-Olov; Retegan, Teodora; Skarnemark, Gunnar [Chalmers Univ. of Technology, Goeteborg (Sweden); Eriksson, Marcus; Seltborg, Per; Wallenius, Jan; Westlen, Daniel [Royal Inst. of Technology, Stockholm (Sweden)

    2007-06-15

    This report is written on behalf of the Swedish reference group for research on partitioning and transmutation. The reference group has been assembled by SKB and its members represent the teams that are active in this field at Swedish universities. The present report summarises the progress in the field through the years 2004-2006. A prerequisite for transmutation by irradiation with neutrons is that the nuclides to be transmuted are separated (partitioned) from the other nuclides in the spent fuel. In particular the remaining uranium must be taken away unless you want to produce more plutonium and other transuranium elements. Separation of the various elements can at least in principle be achieved by mechanical and chemical processes. Currently there exist some large scale facilities for separation of uranium and plutonium from the spent fuel-reprocessing plants. These can, however, not separate the minor actinides - neptunium, americium and curium - from the high level waste that goes to a repository. Plutonium constitutes about 90% of the transuranium elements in fuel from light water reactors. The objective of current research on partitioning is to find and develop processes suitable for separation of the heavier actinides (and possibly some long-lived fission products) on an industrial scale. The objective of current research on transmutation is to define, investigate and develop facilities that may be suitable for transmutation of the aforementioned long-lived radionuclides. The research on partitioning has made important progress in recent years. In some cases one has succeeded to separate americium and curium. Many challenges remain however. Within hydrochemistry one has achieved sufficiently good distribution and separation factors. The focus turns now towards development of an operating process. The search for ligands that give sufficiently good extraction and separation will continue but with less intensity. The emphasis will rather be on improving

  11. HIGH-FIDELITY RADIO ASTRONOMICAL POLARIMETRY USING A MILLISECOND PULSAR AS A POLARIZED REFERENCE SOURCE

    Energy Technology Data Exchange (ETDEWEB)

    Van Straten, W., E-mail: vanstraten.willem@gmail.com [Centre for Astrophysics and Supercomputing, Swinburne University of Technology, Hawthorn, VIC 3122 (Australia)

    2013-01-15

    A new method of polarimetric calibration is presented in which the instrumental response is derived from regular observations of PSR J0437-4715 based on the assumption that the mean polarized emission from this millisecond pulsar remains constant over time. The technique is applicable to any experiment in which high-fidelity polarimetry is required over long timescales; it is demonstrated by calibrating 7.2 years of high-precision timing observations of PSR J1022+1001 made at the Parkes Observatory. Application of the new technique followed by arrival time estimation using matrix template matching yields post-fit residuals with an uncertainty-weighted standard deviation of 880 ns, two times smaller than that of arrival time residuals obtained via conventional methods of calibration and arrival time estimation. The precision achieved by this experiment yields the first significant measurements of the secular variation of the projected semimajor axis, the precession of periastron, and the Shapiro delay; it also places PSR J1022+1001 among the 10 best pulsars regularly observed as part of the Parkes Pulsar Timing Array (PPTA) project. It is shown that the timing accuracy of a large fraction of the pulsars in the PPTA is currently limited by the systematic timing error due to instrumental polarization artifacts. More importantly, long-term variations of systematic error are correlated between different pulsars, which adversely affects the primary objectives of any pulsar timing array experiment. These limitations may be overcome by adopting the techniques presented in this work, which relax the demand for instrumental polarization purity and thereby have the potential to reduce the development cost of next-generation telescopes such as the Square Kilometre Array.

  12. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2013-01-01

    Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops and the mat......Power electronics based MicroGrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of parallel connected three-phase VSIs are derived. The proposed voltage and current inner control loops...... control restores the frequency and amplitude deviations produced by the primary control. Also, a synchronization algorithm is presented in order to connect the MicroGrid to the grid. Experimental results are provided to validate the performance and robustness of the parallel VSI system control...

  13. Development of long lifetime-high current plasma cathode ion source

    International Nuclear Information System (INIS)

    Yabe, Eiji; Takayama, Kazuo; Fukui, Ryota.

    1987-01-01

    A long lifetime ion source with plasma cathode has been developed for use in ion implantation. In this ion source, a plasma of a nonreactive working gas serves as a cathode in place of a thermionic tungsten filament used in the Freeman ion source. In an applied magnetic field, the plasma cathode is convergent, i.e. filament-like; in zero magnetic field, it turns divergent and spray-like. In the latter case, the plasma exhibits a remarkable ability when the working gas has an ionization potential larger than the feed gas. By any combination of a working gas of either argon or neon and a feed gas of AsF 5 or PF 5 , the lifetime of this ion source was found to be more than 90 hours with an extraction voltage of 40 kV and the corresponding ion current density 20 mA/cm 2 . Mass spectrometry results show that this ion source has an ability of generating a considerable amount of As + and P + ions from AsF 5 and PF 5 , and hence will be useful for realizing a fully cryopumped ion implanter system. This ion source is eminently suitable for use in oxygen ion production. (author)

  14. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source

    Energy Technology Data Exchange (ETDEWEB)

    Waldmann, Ole; Ludewigt, Bernhard [Lawrence Berkeley National Laboratory, 1 Cyclotron Road, Berkeley, California 94720 (United States)

    2011-11-15

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm{sup 2} have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material.

  15. Measurements of beam current density and proton fraction of a permanent-magnet microwave ion source.

    Science.gov (United States)

    Waldmann, Ole; Ludewigt, Bernhard

    2011-11-01

    A permanent-magnet microwave ion source has been built for use in a high-yield, compact neutron generator. The source has been designed to produce up to 100 mA of deuterium and tritium ions. The electron-cyclotron resonance condition is met at a microwave frequency of 2.45 GHz and a magnetic field strength of 87.5 mT. The source operates at a low hydrogen gas pressure of about 0.15 Pa. Hydrogen beams with a current density of 40 mA/cm(2) have been extracted at a microwave power of 450 W. The dependence of the extracted proton beam fraction on wall materials and operating parameters was measured and found to vary from 45% for steel to 95% for boron nitride as a wall liner material. © 2011 American Institute of Physics

  16. Design of Programmable LED Controller with a Variable Current Source for 3D Image Display

    Directory of Open Access Journals (Sweden)

    Kyung-Ryang Lee

    2014-12-01

    Full Text Available Conventional fluorescent light sources, as well as incandescent light sources are gradually being replaced by Light Emitting Diodes (LEDs for reducing power consumption in the image display area for multimedia application. An LED light source requires a controller with a low-power operation. In this paper, a low-power technique using adiabatic operation is applied for the implementation of LED controller with a stable constant-current, a low-power and low-heat function. From the simulation result, the power consumption of the proposed LED controller using adiabatic operation was reduced to about 87% in comparison with conventional operation with a constant VDD. The proposed circuit is expected to be an alternative LED controller which is sensitive to external conditions such as heat.

  17. Microwave proton source development for a high-current linac injector

    International Nuclear Information System (INIS)

    Sherman, J.; Bolme, G.; Geisik, C.

    1995-01-01

    Powerful CW proton linear accelerators (100-mA at 0.5--1.0 GeV) are being proposed for spallation neutron-source applications. A 75-keV, 110-mA dc proton injector using a microwave ion source is being tested for these applications. It has achieved 80-keV, 110-mA hydrogen-ion-beam operation. Video and dc beam-current toroid diagnostics are operational, and an EPICS control system is also operational on the 75-keV injector. A technical base development program has also been carried out on a 50-keV injector obtained from Chalk River Laboratories, and it includes low-energy beam transport studies, ion source lifetime tests, and proton-fraction enhancement studies. Technical base results and the present status of the 75-keV injector will be presented

  18. Removal of Direct Current Link Harmonic Ripple in Single Phase Voltage Source Inverter Systems Using Supercapacitors

    Science.gov (United States)

    2016-09-01

    Khaligh, “Optimization of sizing and battery cycle life in battery/ultracapacitor hybrid energy storage systems for electric vehicle applications...depth cycling operation in photovoltaic system ,” in 22nd International Conference “Mixed Design of Integrated Circuits and Systems ,” Toruń, Poland...CURRENT LINK HARMONIC RIPPLE IN SINGLE-PHASE VOLTAGE SOURCE INVERTER SYSTEMS USING SUPERCAPACITORS by Gabriel D. Hernandez September 2016

  19. Current developments with TRIUMF’s titanium-sapphire laser based resonance ionization laser ion source

    Energy Technology Data Exchange (ETDEWEB)

    Lassen, J., E-mail: LASSEN@triumf.ca; Li, R. [TRIUMF (Canada); Raeder, S. [GSI Helmholtzzentrum für Schwerionenforschung GmbH (Germany); Zhao, X.; Dekker, T. [TRIUMF (Canada); Heggen, H. [GSI Helmholtzzentrum für Schwerionenforschung GmbH (Germany); Kunz, P.; Levy, C. D. P.; Mostanmand, M.; Teigelhöfer, A.; Ames, F. [TRIUMF (Canada)

    2017-11-15

    Developments at TRIUMF’s isotope separator and accelerator (ISAC) resonance ionization laser ion source (RILIS) in the past years have concentrated on increased reliability for on-line beam delivery of radioactive isotopes to experiments, as well as increasing the number of elements available through resonance ionization and searching for ionization schemes with improved efficiency. The current status of these developments is given with a list of two step laser ionization schemes implemented recently.

  20. An open source, 3D printed preclinical MRI phantom for repeated measures of contrast agents and reference standards.

    Science.gov (United States)

    Cox, B L; Ludwig, K D; Adamson, E B; Eliceiri, K W; Fain, S B

    2018-03-01

    In medical imaging, clinicians, researchers and technicians have begun to use 3D printing to create specialized phantoms to replace commercial ones due to their customizable and iterative nature. Presented here is the design of a 3D printed open source, reusable magnetic resonance imaging (MRI) phantom, capable of flood-filling, with removable samples for measurements of contrast agent solutions and reference standards, and for use in evaluating acquisition techniques and image reconstruction performance. The phantom was designed using SolidWorks, a computer-aided design software package. The phantom consists of custom and off-the-shelf parts and incorporates an air hole and Luer Lock system to aid in flood filling, a marker for orientation of samples in the filled mode and bolt and tube holes for assembly. The cost of construction for all materials is under $90. All design files are open-source and available for download. To demonstrate utility, B 0 field mapping was performed using a series of gadolinium concentrations in both the unfilled and flood-filled mode. An excellent linear agreement (R 2 >0.998) was observed between measured relaxation rates (R 1 /R 2 ) and gadolinium concentration. The phantom provides a reliable setup to test data acquisition and reconstruction methods and verify physical alignment in alternative nuclei MRI techniques (e.g. carbon-13 and fluorine-19 MRI). A cost-effective, open-source MRI phantom design for repeated quantitative measurement of contrast agents and reference standards in preclinical research is presented. Specifically, the work is an example of how the emerging technology of 3D printing improves flexibility and access for custom phantom design.

  1. Energization of the Ring Current through Convection of Substorm Enhancements of the Plasma Sheet Source.

    Science.gov (United States)

    Menz, A.; Kistler, L. M.; Mouikis, C.; Spence, H. E.; Henderson, M. G.; Matsui, H.

    2017-12-01

    It has been shown that electric field strength and night-side plasma sheet density are the two best predictors of the adiabatic energy gain of the ring current during geomagnetic storms (Liemohn and Khazanov, 2005). While H+ dominates the ring current during quiet times, O+ can contribute substantially during geomagnetic storms. Substorm activity provides a mechanism to enhance the energy density of O+ in the plasma sheet during geomagnetic storms, which is then convected adiabatically into the inner-magnetosphere. Using the Van Allen Probes data in the the plasma sheet source region (defined as L>5.5 during storms) and the inner magnetosphere, along with LANL-GEO data to identify substorm injection times, we show that adiabatic convection of O+ enhancements in the source region can explain the observed enhancements in the inner magnetosphere. We use the UNH-IMEF electric field model to calculate drift times from the source region to the inner magnetosphere to test whether enhancements in the inner-magnetosphere can be explained by dipolarization driven enhancements in the plasma sheet source hours before.

  2. Applying geochemical signatures of atmospheric dust to distinguish current mine emissions from legacy sources

    Science.gov (United States)

    Dong, Chenyin; Taylor, Mark Patrick

    2017-07-01

    Resolving the source of environmental contamination is the critical first step in remediation and exposure prevention. Australia's oldest silver-zinc-lead mine at Broken Hill (>130 years old) has generated a legacy of contamination and is associated with persistent elevated childhood blood lead (Pb) levels. However, the source of environmental Pb remains in dispute: current mine emissions; remobilized mine-legacy lead in soils and dusts; and natural lead from geological weathering of the gossan ore body. Multiple lines of evidence used to resolve this conundrum at Broken Hill include spatial and temporal variations in dust Pb concentrations and bioaccessibility, Pb isotopic compositions, particle morphology and mineralogy. Total dust Pb loading (mean 255 μg/m2/day) and its bioaccessibility (mean 75% of total Pb) is greatest adjacent to the active mining operations. Unweathered galena (PbS) found in contemporary dust deposits contrast markedly to Pb-bearing particles from mine-tailings and weathered gossan samples. Contemporary dust particles were more angular, had higher sulfur content and had little or no iron and manganese. Dust adjacent to the mine has Pb isotopic compositions (208Pb/207Pb: 2.3197; 206Pb/207Pb: 1.0406) that are a close match (99%) to the ore body with values slightly lower (94%) at the edge of the city. The weight of evidence supports the conclusion that contemporary dust Pb contamination in Broken Hill is sourced primarily from current mining activities and not from weathering or legacy sources.

  3. Galvanically Decoupled Current Source Modules for Multi-Channel Bioimpedance Measurement Systems

    Directory of Open Access Journals (Sweden)

    Roman Kusche

    2017-10-01

    Full Text Available Bioimpedance measurements have become a useful technique in the past several years in biomedical engineering. Especially, multi-channel measurements facilitate new imaging and patient monitoring techniques. While most instrumentation research has focused on signal acquisition and signal processing, this work proposes the design of an excitation current source module that can be easily implemented in existing or upcoming bioimpedance measurement systems. It is galvanically isolated to enable simultaneous multi-channel bioimpedance measurements with a very low channel-coupling. The system is based on a microcontroller in combination with a voltage-controlled current source circuit. It generates selectable sinusoidal excitation signals between 0.12 and 1.5 mA in a frequency range from 12 to 250 kHz, whereas the voltage compliance range is ±3.2 V. The coupling factor between two current sources, experimentally galvanically connected with each other, is measured to be less than −48 dB over the entire intended frequency range. Finally, suggestions for developments in the future are made.

  4. Prototype high current, high duty factor negative hydrogen ion source for LAMPF

    International Nuclear Information System (INIS)

    Lawrence, G.P.; Hayward, T.D.; Jackson, J.A.

    1975-01-01

    Present plans for the high current proton storage ring at LAMPF incorporate charge changing (stripping) injection of H - ions in all modes of operation. Achievable stored current levels in this device will be strongly dependent on the maximum H - beam intensity which can be accelerated by the linac, consistent with acceptable beam spill. This requirement has stimulated a program to develop an H - ion source capable of providing a suitably high peak current (up to 25 mA) at high duty factor (up to 12 percent), with a normalized x,x' or y,y' emittance acceptable to the accelerating system. There are presently two main approaches which could lead to H - ion sources providing this kind of performance. These are (a) the charge exchange method, in which an intense proton beam is fractionally converted to H - beam in a suitable charge adding medium, and (b) the direct extraction method, in which H - ions are obtained by a surface emission process associated with a gas discharge plasma. While both approaches may eventually find optimum application in different situations, it is not obvious, at present, which scheme will turn out to be the most satisfactory for LAMPF. A prototype charge exchange H - ion source has been constructed as a first step in the development program and is presently being evaluated. Work on surface emission direct extraction techniques is in the planning stages. (U.S.)

  5. Extracting functional components of neural dynamics with Independent Component Analysis and inverse Current Source Density.

    Science.gov (United States)

    Lęski, Szymon; Kublik, Ewa; Swiejkowski, Daniel A; Wróbel, Andrzej; Wójcik, Daniel K

    2010-12-01

    Local field potentials have good temporal resolution but are blurred due to the slow spatial decay of the electric field. For simultaneous recordings on regular grids one can reconstruct efficiently the current sources (CSD) using the inverse Current Source Density method (iCSD). It is possible to decompose the resultant spatiotemporal information about the current dynamics into functional components using Independent Component Analysis (ICA). We show on test data modeling recordings of evoked potentials on a grid of 4 × 5 × 7 points that meaningful results are obtained with spatial ICA decomposition of reconstructed CSD. The components obtained through decomposition of CSD are better defined and allow easier physiological interpretation than the results of similar analysis of corresponding evoked potentials in the thalamus. We show that spatiotemporal ICA decompositions can perform better for certain types of sources but it does not seem to be the case for the experimental data studied. Having found the appropriate approach to decomposing neural dynamics into functional components we use the technique to study the somatosensory evoked potentials recorded on a grid spanning a large part of the forebrain. We discuss two example components associated with the first waves of activation of the somatosensory thalamus. We show that the proposed method brings up new, more detailed information on the time and spatial location of specific activity conveyed through various parts of the somatosensory thalamus in the rat.

  6. Source brightness and useful beam current of carbon nanotubes and other very small emitters

    International Nuclear Information System (INIS)

    Kruit, P.; Bezuijen, M.; Barth, J.E.

    2006-01-01

    The potential application of carbon nanotubes as electron sources in electron microscopes is analyzed. The resolution and probe current that can be obtained from a carbon nanotube emitter in a low-voltage scanning electron microscope are calculated and compared to the state of the art using Schottky electron sources. Many analytical equations for probe-size versus probe-current relations in different parameter regimes are obtained. It is shown that for most carbon nanotube emitters, the gun lens aberrations are larger than the emitters' virtual source size and thus restrict the microscope's performance. The result is that the advantages of the higher brightness of nanotube emitters are limited unless the angular emission current is increased over present day values or the gun lens aberrations are decreased. For some nanotubes with a closed cap, it is known that the emitted electron beam is coherent over the full emission cone. We argue that for such emitters the parameter ''brightness'' becomes meaningless. The influence of phase variations in the electron wave front emitted from such a nanotube emitter on the focusing of the electron beam is analyzed

  7. Adiabatic energization in the ring current and its relation to other source and loss terms

    Science.gov (United States)

    Liemohn, M. W.; Kozyra, J. U.; Clauer, C. R.; Khazanov, G. V.; Thomsen, M. F.

    2002-04-01

    The influence of adiabatic energization and deenergization effects, caused by particle drift in radial distance, on ring current growth rates and loss lifetimes is investigated. Growth and loss rates from simulation results of four storms (5 June 1991, 15 May 1997, 19 October 1998, and 25 September 1998) are examined and compared against the y component of the solar wind electric field (Ey,sw). Energy change rates with and without the inclusion of adiabatic energy changes are considered to isolate the influence of this mechanism in governing changes of ring current strength. It is found that the influence of adiabatic drift effects on the energy change rates is very large when energization and deenergization are considered separately as gain and loss mechanisms, often about an order of magnitude larger than all other source or loss terms combined. This is true not only during storm times, when the open drift path configuration of the hot ions dominates the physics of the ring current, but also during quiet times, when the small oscillation in L of the closed trajectories creates a large source and loss of energy each drift orbit. However, the net energy change from adiabatic drift is often smaller than other source and loss processes, especially during quiet times. Energization from adiabatic drift dominates ring current growth only during portions of the main phase of storms. Furthermore, the net-adiabatic energization is often positive, because some particles are lost in the inner magnetosphere before they can adiabatically deenergize. It is shown that the inclusion of only this net-adiabatic drift effect in the total source rate or loss lifetime (depending on the sign of the net-adiabatic energization) best matches the observed source and loss values from empirical Dst predictor methods (that is, for consistency, these values should be compared between the calculation methods). While adiabatic deenergization dominates the loss timescales for all Ey,sw values

  8. Development of a high average current polarized electron source with long cathode operational lifetime

    Energy Technology Data Exchange (ETDEWEB)

    C. K. Sinclair; P. A. Adderley; B. M. Dunham; J. C. Hansknecht; P. Hartmann; M. Poelker; J. S. Price; P. M. Rutt; W. J. Schneider; M. Steigerwald

    2007-02-01

    Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory) require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2?105???C/cm2 and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  9. Design and simulation of a nanoelectronic DG MOSFET current source using artificial neural networks

    International Nuclear Information System (INIS)

    Djeffal, F.; Dibi, Z.; Hafiane, M.L.; Arar, D.

    2007-01-01

    The double gate (DG) MOSFET has received great attention in recent years owing to the inherent suppression of short channel effects (SCEs), excellent subthreshold slope (S), improved drive current (I ds ) and transconductance (gm), volume inversion for symmetric devices and excellent scalability. Therefore, simulation tools which can be applied to design nanoscale transistors in the future require new theory and modeling techniques that capture the physics of quantum transport accurately and efficiently. In this sense, this work presents the applicability of the artificial neural networks (ANN) for the design and simulation of a nanoelectronic DG MOSFET current source. The latter is based on the 2D numerical Non-Equilibrium Green's Function (NEGF) simulation of the current-voltage characteristics of an undoped symmetric DG MOSFET. Our results are discussed in order to obtain some new and useful information about the ULSI technology

  10. Evaluation of local electric fields generated by transcranial direct current stimulation with an extracephalic reference electrode based on realistic 3D body modeling

    Science.gov (United States)

    Im, Chang-Hwan; Park, Ji-Hye; Shim, Miseon; Chang, Won Hyuk; Kim, Yun-Hee

    2012-04-01

    In this study, local electric field distributions generated by transcranial direct current stimulation (tDCS) with an extracephalic reference electrode were evaluated to address extracephalic tDCS safety issues. To this aim, we generated a numerical model of an adult male human upper body and applied the 3D finite element method to electric current conduction analysis. In our simulations, the active electrode was placed over the left primary motor cortex (M1) and the reference electrode was placed at six different locations: over the right temporal lobe, on the right supraorbital region, on the right deltoid, on the left deltoid, under the chin, and on the right buccinator muscle. The maximum current density and electric field intensity values in the brainstem generated by the extracephalic reference electrodes were comparable to, or even less than, those generated by the cephalic reference electrodes. These results suggest that extracephalic reference electrodes do not lead to unwanted modulation of the brainstem cardio-respiratory and autonomic centers, as indicated by recent experimental studies. The volume energy density was concentrated at the neck area by the use of deltoid reference electrodes, but was still smaller than that around the active electrode locations. In addition, the distributions of elicited cortical electric fields demonstrated that the use of extracephalic reference electrodes might allow for the robust prediction of cortical modulations with little dependence on the reference electrode locations.

  11. Sources

    International Nuclear Information System (INIS)

    Duffy, L.P.

    1991-01-01

    This paper discusses the sources of radiation in the narrow perspective of radioactivity and the even narrow perspective of those sources that concern environmental management and restoration activities at DOE facilities, as well as a few related sources. Sources of irritation, Sources of inflammatory jingoism, and Sources of information. First, the sources of irritation fall into three categories: No reliable scientific ombudsman to speak without bias and prejudice for the public good, Technical jargon with unclear definitions exists within the radioactive nomenclature, and Scientific community keeps a low-profile with regard to public information. The next area of personal concern are the sources of inflammation. This include such things as: Plutonium being described as the most dangerous substance known to man, The amount of plutonium required to make a bomb, Talk of transuranic waste containing plutonium and its health affects, TMI-2 and Chernobyl being described as Siamese twins, Inadequate information on low-level disposal sites and current regulatory requirements under 10 CFR 61, Enhanced engineered waste disposal not being presented to the public accurately. Numerous sources of disinformation regarding low level radiation high-level radiation, Elusive nature of the scientific community, The Federal and State Health Agencies resources to address comparative risk, and Regulatory agencies speaking out without the support of the scientific community

  12. Variable speed wind turbine generator system with current controlled voltage source inverter

    International Nuclear Information System (INIS)

    Muyeen, S.M.; Al-Durra, Ahmed; Tamura, J.

    2011-01-01

    highlights: → Current controlled voltage source inverter scheme for wind power application. → Low voltage ride through of wind farm. → Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  13. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  14. Modelling and simulation of current fed dc to dc converter for PHEV applications using renewable source

    Science.gov (United States)

    Milind Metha, Manish; Tutki, Sanjay; Rajan, Aju; Elangovan, D.; Arunkumar, G.

    2017-11-01

    With the current rate of depletion of the fossil fuel the need to switch on to the renewable energy sources is the need of the hour. Thus the need for new and efficient converters arises so as to replace the existing less efficient diesel and petroleum IC engines with renewable energy sources. The PHEVs, which have been launched in the market, and Upcoming PHEVs have converters around 380V to 400V generated with a power range between 2KW to 2.8KW. The fundamental target of this paper is to plan a productive converter keeping in mind cost and size restriction. In this paper, a two-stage dc-dc converter is proposed. The proposed converter is utilized to venture up a voltage from 24V (photovoltaic source) to a yield voltage of 400V to take care of a power demand of 2.4kW for a plug-in hybrid electric vehicle (PHEV) application considering the real time scenario of PHEV. This paper talks about in detail why the current fed converter is utilized alongside a voltage doubler thus minimizing the transformer turns thereby reducing the overall size of the final product. Simulation results along with calculation for the duty cycle of the firing sequence for different value of transformer turns are presented for a prototype unit.

  15. Reference masses for precision mass spectrometry design and implementation of a Pierce geometry to the cluster Ion source at ISOLTRAP

    CERN Document Server

    Lommen, Jonathan

    At the mass spectrometer ISOLTRAP carbon clusters ($^{12}$Cn, 1$\\leqslant$n$\\leqslant$25) are provided as reference masses, which are of particular importance in higher mass ranges (m $\\geqslant$ 200u). In this mass range the measurlment uncertainty is increasingly dominated by the difference of the reference mass and the mass of the ion of interest. Using carbon clusters instead of the common $^{133}$Cs ions, this difference decreases. The carbon clusters are produced in a laser ion source which has been improved in the frame of this thesis. The fluctuations of the count rate have been investigated as a function of the laser energy. Furthermore, the energy density at the target has been increased by implementation of a telescope into the laser beam line, which leads to a more narrow energy distribution of the ions. Through the exact adjustment of timing and length of a pulsed cavity an energy range with constant count rate could be selected. In order to provide ideal starting conditions during and after the ...

  16. Assessing harmonic current source modelling and power definitions in balanced and unbalanced networks

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson-Hope, Gary; Stemmet, W.C. [Cape Peninsula University of Technology, Cape Town Campus, Cape Town (South Africa)

    2006-07-01

    The purpose of this paper is to assess the DlgSILENT PowerFactory software power definitions (indices) in terms of phase and sequence components for balanced and unbalanced networks when harmonic distortion is present and to compare its results to hand calculations done, following recommendation made by the IEEE Working Group on this topic. This paper also includes the development of a flowchart for calculating power indices in balanced and unbalanced three-phase networks when non-sinusoidal voltages and currents are present. A further purpose is to determine how two industrial grade harmonic analysis software packages (DlgSILENT and ERACS) model three-phase harmonic sources used for current penetration studies and to compare their results when applied to a network. From the investigations, another objective was to develop a methodology for modelling harmonic current sources based on a spectrum obtained from measurements. Three case studies were conducted and the assessment and developed methodologies were shown to be effective. (Author)

  17. An Improved Current-Doubler Rectifier for the Marine Controlled Source Electromagnetic Transmitter

    Directory of Open Access Journals (Sweden)

    Hongxi Song

    2018-01-01

    Full Text Available High power marine controlled source electromagnetic transmitters have gained interest with applications in marine geological survey and mineral resources exploration. The direct current to direct current (DC-DC converter that is typically used in marine transmitters has some issues, as the insulated-gate bipolar transistor (IGBT tube cannot achieve zero-voltage switching (ZVS. In particular, lagging-leg switching cannot easily achieve ZVS. The conversion efficiency of the heat converter requires improvement. This paper proposes an improved current-doubler rectifier for the marine controlled source electromagnetic transmitter (ICDR-MCSET. Resonant inductance is increased and a blocking capacitor is added to the converter (DC-DC circuit, where the converter can achieve ZVS in a wide load range. This results in the effective decrease of the heating temperature and the improvement of transformation efficiency. Saber software simulation and a 20 KW electromagnetic transmitter are used to verify the results, which show that the method is feasible and effective.

  18. External heating and current drive source requirements towards steady-state operation in ITER

    Science.gov (United States)

    Poli, F. M.; Kessel, C. E.; Bonoli, P. T.; Batchelor, D. B.; Harvey, R. W.; Snyder, P. B.

    2014-07-01

    Steady state scenarios envisaged for ITER aim at optimizing the bootstrap current, while maintaining sufficient confinement and stability to provide the necessary fusion yield. Non-inductive scenarios will need to operate with internal transport barriers (ITBs) in order to reach adequate fusion gain at typical currents of 9 MA. However, the large pressure gradients associated with ITBs in regions of weak or negative magnetic shear can be conducive to ideal MHD instabilities, reducing the no-wall limit. The E × B flow shear from toroidal plasma rotation is expected to be low in ITER, with a major role in the ITB dynamics being played by magnetic geometry. Combinations of heating and current drive (H/CD) sources that sustain reversed magnetic shear profiles throughout the discharge are the focus of this work. Time-dependent transport simulations indicate that a combination of electron cyclotron (EC) and lower hybrid (LH) waves is a promising route towards steady state operation in ITER. The LH forms and sustains expanded barriers and the EC deposition at mid-radius freezes the bootstrap current profile stabilizing the barrier and leading to confinement levels 50% higher than typical H-mode energy confinement times. Using LH spectra with spectrum centred on parallel refractive index of 1.75-1.85, the performance of these plasma scenarios is close to the ITER target of 9 MA non-inductive current, global confinement gain H98 = 1.6 and fusion gain Q = 5.

  19. LORETA current source density for duration mismatch negativity and neuropsychological assessment in early schizophrenia.

    Directory of Open Access Journals (Sweden)

    Tomohiro Miyanishi

    Full Text Available INTRODUCTION: Patients with schizophrenia elicit cognitive decline from the early phase of the illness. Mismatch negativity (MMN has been shown to be associated with cognitive function. We investigated the current source density of duration mismatch negativity (dMMN, by using low-resolution brain electromagnetic tomography (LORETA, and neuropsychological performance in subjects with early schizophrenia. METHODS: Data were obtained from 20 patients meeting DSM-IV criteria for schizophrenia or schizophreniform disorder, and 20 healthy control (HC subjects. An auditory odd-ball paradigm was used to measure dMMN. Neuropsychological performance was evaluated by the brief assessment of cognition in schizophrenia Japanese version (BACS-J. RESULTS: Patients showed smaller dMMN amplitudes than those in the HC subjects. LORETA current density for dMMN was significantly lower in patients compared to HC subjects, especially in the temporal lobes. dMMN current density in the frontal lobe was positively correlated with working memory performance in patients. CONCLUSIONS: This is the first study to identify brain regions showing smaller dMMN current density in early schizophrenia. Further, poor working memory was associated with decreased dMMN current density in patients. These results are likely to help understand the neural basis for cognitive impairment of schizophrenia.

  20. Autonomous Energy Sources in the North of the Far East: Current State and Directions of Diversification

    Directory of Open Access Journals (Sweden)

    Boris Grigorievich Saneev

    2018-03-01

    Full Text Available The paper presents the current state of autonomous energy sources in the north of the Far East. Consideration is given to the capacity structures with a focus on industrial and residential autonomous energy sources. One of the main problems facing power supply to residential consumers in the north of the Far East is the insufficiently developed transport infrastructure, which causes complicated fuel delivery patterns, fuel price rise, and hence high electricity generation cost. The changes in the installed capacity of renewable energy sources (RES in the north of the Far East are demonstrated for the period between 2011 and 2015. The research shows the main directions of power production diversification in the north of the Far East. The directions include the use of local fuel types, the development of cogeneration, the involvement of renewable energy sources and small-scale nuclear power plants. The paper presents a forecast for the renewable energy development in the north of the Far East up to 2035, made by the authors. The priority RES projects in the off-grid power supply in the north of the Far East are wind and solar power plants

  1. Modeling, analysis, and design of stationary reference frame droop controlled parallel three-phase voltage source inverters

    DEFF Research Database (Denmark)

    Vasquez, Juan Carlos; Guerrero, Josep M.; Savaghebi, Mehdi

    2011-01-01

    and discussed. Experimental results are provided to validate the performance and robustness of the VSIs functionality during Islanded and grid-connected operations, allowing a seamless transition between these modes through control hierarchies by regulating frequency and voltage, main-grid interactivity......Power electronics based microgrids consist of a number of voltage source inverters (VSIs) operating in parallel. In this paper, the modeling, control design, and stability analysis of three-phase VSIs are derived. The proposed voltage and current inner control loops and the mathematical models...

  2. A method for making an inert porous electrode for a chemical current source

    Energy Technology Data Exchange (ETDEWEB)

    Ksenzhek, O.S.; Litvinova, V.I.; Martynenko, T.L.; Raykhelson, L.B.; Shembel, Ye.M.; Sokolov, L.A.

    1983-01-01

    A method is proposed for making an inert, porous electrode for chemical current sources (KhIT) with a nonaqueous electrolyte on the basis of aprotonic solvents and an active cathode substance which is dissolved in the electrolyte. The method includes preparing an electrode mass from the starting material and subsequent formation of the electrode. To increase the energy capacity, after formation, the electrode is subjected to electrochemical anode polarization to potentials which correspond to the potential of electrochemical breakdown of the background electrolyte.

  3. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  4. A Single Rod Multi-modality Multi-interface Level Sensor Using an AC Current Source

    Directory of Open Access Journals (Sweden)

    Abdulgader Hwili

    2008-05-01

    Full Text Available Crude oil separation is an important process in the oil industry. To make efficient use of the separators, it is important to know their internal behaviour, and to measure the levels of multi-interfaces between different materials, such as gas-foam, foam-oil, oil-emulsion, emulsion-water and water-solids. A single-rod multi-modality multi-interface level sensor is presented, which has a current source, and electromagnetic modalities. Some key issues have been addressed, including the effect of salt content and temperature i.e. conductivity on the measurement.

  5. Numerical studies of the flux-to-current ratio method in the KIPT neutron source facility

    International Nuclear Information System (INIS)

    Cao, Y.; Gohar, Y.; Zhong, Z.

    2013-01-01

    The reactivity of a subcritical assembly has to be monitored continuously in order to assure its safe operation. In this paper, the flux-to-current ratio method has been studied as an approach to provide the on-line reactivity measurement of the subcritical system. Monte Carlo numerical simulations have been performed using the KIPT neutron source facility model. It is found that the reactivity obtained from the flux-to-current ratio method is sensitive to the detector position in the subcritical assembly. However, if multiple detectors are located about 12 cm above the graphite reflector and 54 cm radially, the technique is shown to be very accurate in determining the k eff this facility in the range of 0.75 to 0.975. (authors)

  6. Changes of cerebral current source by audiovisual erotic stimuli in premature ejaculation patients.

    Science.gov (United States)

    Hyun, Jae-Seog; Kam, Sung-Chul; Kwon, Oh-Young

    2008-06-01

    Premature ejaculation (PE) is one of the most common forms of male sexual dysfunction. The mechanisms of PE remain poorly understood, despite its high prevalence. To investigate the pathophysiology and causes of PE in the central nervous system, we tried to observe the changes in brain current source distribution by audiovisual induction of sexual arousal. Electroencephalograpies were recorded in patients with PE (45.0 +/- 10.3 years old, N = 18) and in controls (45.6 +/- 9.8 years old, N = 18) during four 10-minute segments of resting, watching a music video excerpt, resting, and watching an erotic video excerpt. Five artifact-free 5-second segments were used to obtain cross-spectral low-resolution brain electromagnetic tomography (LORETA) images. Statistical nonparametric maps (SnPM) were obtained to detect the current density changes of six frequency bands between the erotic video session and the music video session in each group. Comparisons were also made between the two groups in the erotic video session. In the SnPM of each spectrum in patients with PE, the current source density of the alpha band was significantly reduced in the right precentral gyrus, the right insula, and both superior parietal lobules (P erotic video session, the current densities of the beta-2 and -3 bands in the PE group were significantly decreased in the right parahippocampal gyrus and left middle temporal gyrus (P < 0.01). Neuronal activity in the right precental gyrus, the right insula, both the superior parietal lobule, the right parahippocampal gyrus, and the left middle temporal gyrus may be decreased in PE patients upon sexual arousal. Further studies are needed to evaluate the meaning of decreased neuronal activities in PE patients.

  7. Development of a high average current polarized electron source with long cathode operational lifetime

    Directory of Open Access Journals (Sweden)

    C. K. Sinclair

    2007-02-01

    Full Text Available Substantially more than half of the electromagnetic nuclear physics experiments conducted at the Continuous Electron Beam Accelerator Facility of the Thomas Jefferson National Accelerator Facility (Jefferson Laboratory require highly polarized electron beams, often at high average current. Spin-polarized electrons are produced by photoemission from various GaAs-based semiconductor photocathodes, using circularly polarized laser light with photon energy slightly larger than the semiconductor band gap. The photocathodes are prepared by activation of the clean semiconductor surface to negative electron affinity using cesium and oxidation. Historically, in many laboratories worldwide, these photocathodes have had short operational lifetimes at high average current, and have often deteriorated fairly quickly in ultrahigh vacuum even without electron beam delivery. At Jefferson Lab, we have developed a polarized electron source in which the photocathodes degrade exceptionally slowly without electron emission, and in which ion back bombardment is the predominant mechanism limiting the operational lifetime of the cathodes during electron emission. We have reproducibly obtained cathode 1/e dark lifetimes over two years, and 1/e charge density and charge lifetimes during electron beam delivery of over 2×10^{5}   C/cm^{2} and 200 C, respectively. This source is able to support uninterrupted high average current polarized beam delivery to three experimental halls simultaneously for many months at a time. Many of the techniques we report here are directly applicable to the development of GaAs photoemission electron guns to deliver high average current, high brightness unpolarized beams.

  8. Study of the nonequilibrium state of superconductors by large quasiparticle injection from an external current source

    International Nuclear Information System (INIS)

    Iguchi, I.

    1977-01-01

    We have studied the nonequilibrium state of superconductors by injecting large numbers of quasiparticles from an external current source into a superconducting film of a tunnel junction with low tunnel resistance (typically 0.1--1 Ω for junction area approx. = 10 -4 cm 2 ). It was observed that there was a critical tunnel current density at which a voltage appeared locally in the part of a superconducting film confined to the junction area. Its values ranged from 10 2 to 10 3 A/cm 2 for bath temperatures well below T/sub c/. Followed by this voltage onset, a transition region corresponding to the nonequilibrium intermediate resistive state was also observed. For further increase of the tunnel current, the local film resistance developed beyond the value of its normal resistance, suggesting that the nonequilibrium state extends far beyond the voltage onset point. A theory based on the modified Rothwarf-Taylor equations and Parker's T* model is presented to compare with the experimental results. The calculated critical current density yielded almost the same order of magnitude as those found experimentally. The detailed behavior, however, deviates from the theoretical predictions although the film makes a second-order transition in the broad range of temperatures. It is also shown using four-terminal analysis that our observations and those by Wong, Yeh, and Langenberg are essentially the same

  9. Use of ultrasound radiation for extraction of bioactive compounds from natural sources. Current events and perspectives

    International Nuclear Information System (INIS)

    Rodriguez Riera, Zalua; Robaina Mesa, Malvis; Jauregui Haza, Ulises

    2014-01-01

    In recent years, clean technologies have been developed for high efficiency extracting of isolation of biologically active compounds from natural sources, without the loss of biological activity, with good yield and high purity. Ultrasound-assisted extraction has low instrumental requirements and their implementation is very appropriate where the stability of the active component to be removed is affected by the high temperatures of conventional processes. In this paper it is evaluated the state of the art of ultrasound-assisted extraction of bioactive compounds from various natural sources, its mechanism, the parameters governing its use and research perspectives in this field. Ultrasonic cavitation phenomenon promotes cell wall rupture, reduction of particle size and tissue permeability, which facilitates the diffusion of the solvent into the inert part of the plant material and increasing the mass transferred through membranes. This mechanism explains the high efficiency of ultrasound-assisted extraction as it allows to reduce the time, temperature and amounts of solvent extraction process with high yields and high purity of the extracted product. Currently there is a great demand for the use of ultrasound to industrial and current research lead to the development of larger scale reactors and the theoretical modeling of the parameters that determine efficient extraction

  10. Novel sources of Flavor Changed Neutral Currents in the 331RHN model

    International Nuclear Information System (INIS)

    Cogollo, D.; Vital de Andrade, A.; Queiroz, F.S.; Teles, P.R.

    2012-01-01

    Sources of Flavor Changed Neutral Currents (FCNC) emerge naturally from a well motivated framework called 3-3-1 with right-handed neutrinos model, 331 RHN for short, mediated by an extra neutral gauge boson Z '. Following previous work we calculate these sources and in addition we derive new ones coming from CP-even and -odd neutral scalars which appear due to their non-diagonal interactions with the physical standard quarks. Furthermore, by using 4 texture zeros for the quark mass matrices, we derive the mass difference terms for the neutral mesons systems K 0 - anti K 0 , D 0 - anti D 0 and B 0 - anti B 0 and show that, though one can discern that the Z' contribution is the most relevant one for mesons oscillations purposes, scalar contributions play a role also in this processes and hence it is worthwhile to investigate them and derive new bounds on space of parameters. In particular, studying the B 0 - anti B 0 system we set the bounds M Z' >or similar 4.2 TeV and M S 2 ,M I 3 >or similar 7.5 TeV in order to be consistent with the current measurements. (orig.)

  11. Municipal solid waste (MSW) as a renewable source of energy: current and future practices in China.

    Science.gov (United States)

    Cheng, Hefa; Hu, Yuanan

    2010-06-01

    With rapid economic growth and massive urbanization, China faces the problem of municipal solid waste (MSW) disposal and the pressing need for development of alternative energy. Waste-to-energy (WTE) incineration, which recovers energy from discarded MSW and produces electricity and/or steam for heating, is recognized as a renewable source of energy and is playing an increasingly important role in MSW management in China. This article provides an overview of the WTE industry, discusses the major challenges in expanding WTE incineration in China, namely, high capital and operational costs, equipment corrosion, air pollutant emissions, and fly ash disposal. A perspective on MSW as a renewable energy source in China is also presented. Currently, only approximately 13% of MSW generated in China is disposed in WTE facilities. With the significant benefits of environmental quality, the reduction of greenhouse gas (GHG) emissions, and government policies and financial incentives as a renewable energy source, WTE incineration industry is expected to experience significant growth in the coming decade and make greater contribution to supplying renewable energy in China. Copyright 2010 Elsevier Ltd. All rights reserved.

  12. Design and implementation of current fed DC-DC converter for PHEV application using renewable source

    Science.gov (United States)

    Milind Metha, Manish; Tutki, Sanjay; Rajan, Aju; Elangovan, D.; Arunkumar, G.

    2017-11-01

    As the fossil fuels are depleting day by day, the use of renewable energy sources came into existence and they evolved a lot lately. To increase efficiency and productivity in the hybrid vehicles, the existence less efficient petroleum and diesel IC engines need to be replaced with the new and efficient converters with renewable energy sources. This has to be done in such a way that impacts three factors mainly: cost, efficiency and reliability. The PHEVs that have been launched and the upcoming PHEVs using converters with voltage range around 380V to 400V generated with power ranges between 2.4KW to 2.8KW. The basic motto of this paper is to design a prolific converter while considering the factor such as cost and size. In this paper, a two stage DC-DC converter is proposed and the proposed DC-DC converter is utilized to endeavour voltage from 24V (photovoltaic source) to a yield voltage of 400V and to meet the power demand of 250W, since only one panel is being used for this proposed paper. This paper discuss in detail about why and how the current fed DC-DC converter is utilized along with a voltage doubler, thus reducing transformer turns and thereby reducing overall size of the product. Simulation and hardware results have been presented along with calculations for duty cycle required for firing sequence for different values of transformer turns.

  13. Current use of imaging and electromagnetic source localization procedures in epilepsy surgery centers across Europe.

    Science.gov (United States)

    Mouthaan, Brian E; Rados, Matea; Barsi, Péter; Boon, Paul; Carmichael, David W; Carrette, Evelien; Craiu, Dana; Cross, J Helen; Diehl, Beate; Dimova, Petia; Fabo, Daniel; Francione, Stefano; Gaskin, Vladislav; Gil-Nagel, Antonio; Grigoreva, Elena; Guekht, Alla; Hirsch, Edouard; Hecimovic, Hrvoje; Helmstaedter, Christoph; Jung, Julien; Kalviainen, Reetta; Kelemen, Anna; Kimiskidis, Vasilios; Kobulashvili, Teia; Krsek, Pavel; Kuchukhidze, Giorgi; Larsson, Pål G; Leitinger, Markus; Lossius, Morten I; Luzin, Roman; Malmgren, Kristina; Mameniskiene, Ruta; Marusic, Petr; Metin, Baris; Özkara, Cigdem; Pecina, Hrvoje; Quesada, Carlos M; Rugg-Gunn, Fergus; Rydenhag, Bertil; Ryvlin, Philippe; Scholly, Julia; Seeck, Margitta; Staack, Anke M; Steinhoff, Bernhard J; Stepanov, Valentin; Tarta-Arsene, Oana; Trinka, Eugen; Uzan, Mustafa; Vogt, Viola L; Vos, Sjoerd B; Vulliémoz, Serge; Huiskamp, Geertjan; Leijten, Frans S S; Van Eijsden, Pieter; Braun, Kees P J

    2016-05-01

    In 2014 the European Union-funded E-PILEPSY project was launched to improve awareness of, and accessibility to, epilepsy surgery across Europe. We aimed to investigate the current use of neuroimaging, electromagnetic source localization, and imaging postprocessing procedures in participating centers. A survey on the clinical use of imaging, electromagnetic source localization, and postprocessing methods in epilepsy surgery candidates was distributed among the 25 centers of the consortium. A descriptive analysis was performed, and results were compared to existing guidelines and recommendations. Response rate was 96%. Standard epilepsy magnetic resonance imaging (MRI) protocols are acquired at 3 Tesla by 15 centers and at 1.5 Tesla by 9 centers. Three centers perform 3T MRI only if indicated. Twenty-six different MRI sequences were reported. Six centers follow all guideline-recommended MRI sequences with the proposed slice orientation and slice thickness or voxel size. Additional sequences are used by 22 centers. MRI postprocessing methods are used in 16 centers. Interictal positron emission tomography (PET) is available in 22 centers; all using 18F-fluorodeoxyglucose (FDG). Seventeen centers perform PET postprocessing. Single-photon emission computed tomography (SPECT) is used by 19 centers, of which 15 perform postprocessing. Four centers perform neither PET nor SPECT in children. Seven centers apply magnetoencephalography (MEG) source localization, and nine apply electroencephalography (EEG) source localization. Fourteen combinations of inverse methods and volume conduction models are used. We report a large variation in the presurgical diagnostic workup among epilepsy surgery centers across Europe. This diversity underscores the need for high-quality systematic reviews, evidence-based recommendations, and harmonization of available diagnostic presurgical methods. Wiley Periodicals, Inc. © 2016 International League Against Epilepsy.

  14. Status Epilepticus Induced Spontaneous Dentate Gyrus Spikes: In Vivo Current Source Density Analysis.

    Directory of Open Access Journals (Sweden)

    Sean P Flynn

    Full Text Available The dentate gyrus is considered to function as an inhibitory gate limiting excitatory input to the hippocampus. Following status epilepticus (SE, this gating function is reduced and granule cells become hyper-excitable. Dentate spikes (DS are large amplitude potentials observed in the dentate gyrus (DG of normal animals. DS are associated with membrane depolarization of granule cells, increased activity of hilar interneurons and suppression of CA3 and CA1 pyramidal cell firing. Therefore, DS could act as an anti-excitatory mechanism. Because of the altered gating function of the dentate gyrus following SE, we sought to investigate how DS are affected following pilocarpine-induced SE. Two weeks following lithium-pilocarpine SE induction, hippocampal EEG was recorded in male Sprague-Dawley rats with 16-channel silicon probes under urethane anesthesia. Probes were placed dorso-ventrally to encompass either CA1-CA3 or CA1-DG layers. Large amplitude spikes were detected from EEG recordings and subject to current source density analysis. Probe placement was verified histologically to evaluate the anatomical localization of current sinks and the origin of DS. In 9 of 11 pilocarpine-treated animals and two controls, DS were confirmed with large current sinks in the molecular layer of the dentate gyrus. DS frequency was significantly increased in pilocarpine-treated animals compared to controls. Additionally, in pilocarpine-treated animals, DS displayed current sinks in the outer, middle and/or inner molecular layers. However, there was no difference in the frequency of events when comparing between layers. This suggests that following SE, DS can be generated by input from medial and lateral entorhinal cortex, or within the dentate gyrus. DS were associated with an increase in multiunit activity in the granule cell layer, but no change in CA1. These results suggest that following SE there is an increase in DS activity, potentially arising from

  15. Determining the normal range for IGF-I, IGFBP-3, and ALS: new reference data based on current internal standards.

    Science.gov (United States)

    Ertl, Diana-Alexandra; Gleiss, Andreas; Sagmeister, Susanne; Haeusler, Gabriele

    2014-09-01

    The measurement of insulin-like growth factors (IGF-I) and insulin-like growth factor-binding protein (IGFBP-3) often serves as first-line testing in children with growth disorders. The role of acid-labile subunit (ALS) as a screening parameter for homozygous or heterozygous mutations of the ALS gene still has to be determined. IGF-I, IGFBP-3, and ALS were measured in 252 samples from children and adolescents. Reference curves were fitted using generalized additive model for location, scale and shape (GAMLSS) models and SD-Scores were calculated. Bootstrap analysis was used to quantify the uncertainty of the estimated percentiles. Bland-Altman plots were used to investigate the discrepancy between our newly estimated standard deviation scores (SDS) and SDS calculated on the basis of previous reference data. We present reference data for enzyme-linked immunosorbent assay (ELISA) measurements based on recommended internal standard for IGF-I, IGFBP-3, and ALS suitable for calculation of SD-scores. The Bland-Altman plot shows a rough agreement between the previous SDS calculation and our new one only for SDS around 1; for SDS at -2, an average difference of 0.83 SD was noticed. Our IGF-I reference values for the interval of interest in diagnosing growth hormone deficiency (GHD) (prepubertal age) are solid as proved by bootstrap analysis. The difference in calculated SD scores by using data provided previously highlights the importance of using labor and method specific reference data.

  16. Reliability of published data on radionuclide half lives - relevance to the use of reference sources for checking instrument performance

    International Nuclear Information System (INIS)

    Waldock, P.M.

    1999-01-01

    Long-lived calibrated radioisotopes are frequently used for checking of instrumentation used in the measurement of radiation; examples include: radioisotope assay meters, radiation monitors and sample counting equipment. In 1986 we purchased a radioisotope calibrator (Capintec CRC120) which was supplied with a number of long-lived check sources by the manufacturer, one of which was barium-133. The source came with its own calibration certificate and a quoted half life of 10.74 years ± 0.05 years, traceable to the National Bureau of Standards in the USA, and is consistent with data published by the National Nuclear Data Center, Brookhaven National Laboratory in 1985 (Tuli 1985). However, we noted at the time that this is significantly different to the value of 7.2 years quoted in the Radiochemical Manual (Wilson 1966) published by the Radiochemical Centre, Amersham (now Nycomed-Amersham), and more recently we have noted that it is significantly different to the value of 10.53 years currently quoted on various Internet sites including the University of Sheffield Chemistry Department (Winter 1999). Further investigation showed similar or worse variations of published half lives with time for several radioisotopes. Letter-to-the-editor

  17. Best Reference Practices are Not Observed in Telephone Ready Reference Services. A review of: Agosto, Denise A. and Holly Anderton. “Whatever Happened to ‘Always Cite the Source?’” Reference & User Services Quarterly 47.1 (2007: 44-54.

    Directory of Open Access Journals (Sweden)

    Julie McKenna

    2008-06-01

    Full Text Available Objective – To study source citing practice in telephone reference service in large public libraries in the United States and Canada. Design – Field simulation (unobtrusive testing.Setting – Large public libraries in the United States and Canada.Subjects – Telephone reference staff of the 25 largest public libraries in the United States and Canada.Methods – The 2005 World Book Almanac was used to select the 25 largest (in terms of population served public libraries in Canada and the United States. Each system’s Web site was checked to locate the telephone number for reference service. For some systems it was necessary to call the general telephone number for the main library or the first branch listed on the Web site. Five ready reference test questions were developed from a list of questions that students in a graduate library and information science course had previously asked of public library telephone reference services. The selected questions in the order that they were asked were: 1. Can you tell me when Valentine’s Day is?2. Who is the current governor/premier (of the state/province where the library is located?3. What is the population of Montana?4. In which state is the Southern Poverty Law Center (SPLC located?5. What is the French word for “chiropractor”?The authors called each of the 25 libraries during five consecutive weeks at different times of the business day. Each week, one question was asked; once an answer was received, no clarification was requested and the call was ended. The study reports the results of 125 reference transactions. For this study, the following definitions were used to assess complete citation for each type of information resource:• For a Web site – the complete URL (title and sponsor of the site not required.• For a digital database – the database title and the title and year of the specific item (author, publisher, page number not required.• For a print resource – the title

  18. Tannins: current knowledge of food sources, intake, bioavailability and biological effects.

    Science.gov (United States)

    Serrano, José; Puupponen-Pimiä, Riitta; Dauer, Andreas; Aura, Anna-Marja; Saura-Calixto, Fulgencio

    2009-09-01

    Tannins are a unique group of phenolic metabolites with molecular weights between 500 and 30 000 Da, which are widely distributed in almost all plant foods and beverages. Proanthocyanidins and hydrolysable tannins are the two major groups of these bioactive compounds, but complex tannins containing structural elements of both groups and specific tannins in marine brown algae have also been described. Most literature data on food tannins refer only to oligomeric compounds that are extracted with aqueous-organic solvents, but a significant number of non-extractable tannins are usually not mentioned in the literature. The biological effects of tannins usually depend on their grade of polymerisation and solubility. Highly polymerised tannins exhibit low bioaccessibility in the small intestine and low fermentability by colonic microflora. This review summarises a new approach to analysis of extractable and non-extractable tannins, major food sources, and effects of storage and processing on tannin content and bioavailability. Biological properties such as antioxidant, antimicrobial and antiviral effects are also described. In addition, the role of tannins in diabetes mellitus has been discussed.

  19. Towards an ankle neuroprosthesis for hybrid robotics: Concepts and current sources for functional electrical stimulation.

    Science.gov (United States)

    Casco, S; Fuster, I; Galeano, R; Moreno, J C; Pons, J L; Brunetti, F

    2017-07-01

    Hybrid rehabilitation robotics combine neuro-prosthetic devices (close-loop functional electrical stimulation systems) and traditional robotic structures and actuators to explore better therapies and promote a more efficient motor function recovery or compensation. Although hybrid robotics and ankle neuroprostheses (NPs) have been widely developed over the last years, there are just few studies on the use of NPs to electrically control both ankle flexion and extension to promote ankle recovery and improved gait patterns in paretic limbs. The aim of this work is to develop an ankle NP specifically designed to work in the field of hybrid robotics. This article presents early steps towards this goal and makes a brief review about motor NPs and Functional Electrical Stimulation (FES) principles and most common devices used to aid the ankle functioning during the gait cycle. It also shows a current sources analysis done in this framework, in order to choose the best one for this intended application.

  20. Estimation of the Plant Time Constant of Current-Controlled Voltage Source Converters

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Malvar, Jano

    2014-01-01

    Precise knowledge of the plant time constant is essential to perform a thorough analysis of the current control loop in voltage source converters (VSCs). As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included...... in the model, through an equivalent series resistance. In a recent work, an algorithm to identify this parameter was developed, considering the inductance value as known and practically constant. Nevertheless, the plant inductance can also present important uncertainties with respect to the inductance...... of the VSC interface filter measured at rated conditions. This paper extends that method so that both parameters of the plant time constant (resistance and inductance) are estimated. Such enhancement is achieved through the evaluation of the closed-loop transient responses of both axes of the synchronous...

  1. Current status of control of radiation sources and radioactive materials in the United Republic of Tanzania

    International Nuclear Information System (INIS)

    Nyaruba, M.M.; Mompome, W.K.

    2001-01-01

    A Protection from Radiation Act was enacted in Tanzania in 1983 to regulate the use of ionizing radiation and protect people against its danger. The Act established a regulatory authority known as National Radiation Commission (NRC), which is the corporate body to enforce the law and regulations. From the beginning of 2000, the NRC has kept inventory of 200 and 324 radiation installations, and radiation sources and radioactive materials in the country, respectively; and has provided personnel monitoring services to 665 radiation workers. However, due to the trade liberalization that is currently being experienced in the country, the increase in the number of radiation practices is observed yearly. To cope with the situation, the whole system of notification, authorization, registration and licensing needs to be improved. The improvement has now started by amending the existing Protection from Radiation Act. (author)

  2. Evaluation of the uniformity of wide circular reference source and application of correction factors; Avaliação da uniformidade de fonte extensa de referência circular e aplicação de fatores de correção

    Energy Technology Data Exchange (ETDEWEB)

    Silva Junior, I.A.; Xavier, M.; Siqueira, P.T.D.; Sordi, G.A.A.; Potiens, M.P.A., E-mail: iremarjr@gmail.com [Instituto de Pesquisas Energéticas e Nucleares (IPEN/CNEN-SP), São Paulo, SP (Brazil)

    2017-07-01

    In this work the uniformity of wide circular reference sources is evaluated. This kind of reference source is still widely used in Brazil. In previous works wide rectangular reference sources were analyzed and it was shown the importance of the application of correction factors in calibration procedures of radiation monitors. Now a transposition of the methods used formerly is performed, evaluating the uniformities of circular reference sources and calculating the associated correction factors. (author)

  3. Survey of currently available reference materials for use in connection with the determination of trace elements in biological materials

    International Nuclear Information System (INIS)

    Parr, R.M.

    1983-09-01

    Elemental analysis of biological materials is at present the subject of intensive study by many different research groups throughout the world, in view of the importance of these trace elements in health and medical diagnosis. IAEA and other organizations are now making a variety of suitable reference materials available for use in connection with the determination of trace elements in biological materials. To help analysts in making a selection from among these various materials, the present report provides a brief survey of data for all such biological reference materials known to the author. These data are compiled by the author from January 1982 to June 1983

  4. Mitigation of grid-current distortion for LCL-filtered grid-connected voltage-source inverter with inverter-side current control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    Due to the low inductance of an LCL-filter, the grid current generated by an LCL-filtered Voltage Source Inverter (VSI) is sensitive to low-order grid-voltage harmonics. This issue is especially tough for the control system with Inverter Current Feedback (ICF), because the grid-current harmonics...... can freely flow into the filter capacitor without control. To cope with this issue, this paper develops an approach for the ICF control system to suppress the grid-current harmonics without adding extra sensors. The proposed method applies harmonic controllers and feedforward scheme simultaneously...

  5. Space Vector Modulation for DC-Link Current Ripple Reduction in Back-To-Back Current Source Converters for Microgrid Applications

    DEFF Research Database (Denmark)

    Guo, Xiaoqiang; Xu, David; Guerrero, Josep M.

    2015-01-01

    Back-to-back converters have been typically used to interconnect the microgrids. For a back-to-back current source converter, the dc-link current ripple is one of the important parameters. A large ripple will cause the electromagnetic interference, undesirable high-frequency losses, and system...... instability. Conventionally, with a given switching frequency and rated voltage, the current ripple can be reduced by increasing the dc-link inductor, but it leads to bulky size, high cost and slow dynamic response. In order to solve this problem, this paper reveals that the current ripple can...

  6. Group Independent Component Analysis (gICA) and Current Source Density (CSD) in the study of EEG in ADHD adults.

    Science.gov (United States)

    Ponomarev, Valery A; Mueller, Andreas; Candrian, Gian; Grin-Yatsenko, Vera A; Kropotov, Juri D

    2014-01-01

    To investigate the performance of the spectral analysis of resting EEG, Current Source Density (CSD) and group independent components (gIC) in diagnosing ADHD adults. Power spectra of resting EEG, CSD and gIC (19 channels, linked ears reference, eyes open/closed) from 96 ADHD and 376 healthy adults were compared between eyes open and eyes closed conditions, and between groups of subjects. Pattern of differences in gIC and CSD spectral power between conditions was approximately similar, whereas it was more widely spatially distributed for EEG. Size effect (Cohen's d) of differences in gIC and CSD spectral power between groups of subjects was considerably greater than in the case of EEG. Significant reduction of gIC and CSD spectral power depending on conditions was found in ADHD patients. Reducing power in a wide frequency range in the fronto-central areas is a common phenomenon regardless of whether the eyes were open or closed. Spectral power of local EEG activity isolated by gICA or CSD in the fronto-central areas may be a suitable marker for discrimination of ADHD and healthy adults. Spectral analysis of gIC and CSD provides better sensitivity to discriminate ADHD and healthy adults. Copyright © 2013 International Federation of Clinical Neurophysiology. Published by Elsevier Ireland Ltd. All rights reserved.

  7. Variability of Surface pollutants and aerosol concentration over Abu Dhabi, UAE - sources, transport and current levels

    Science.gov (United States)

    Phanikumar, Devulapalli V.; Basha, Ghouse; Ouarda, Taha B. M. J.

    2015-04-01

    pollutants are in contrast with the diurnal pattern of wind speed as evident from the previous observations. Wind rose diagram of pollutants reveal that the dominant source directions are scattered from northwesterly to southwesterly. Our results (2011-13) are compared with earlier observations from the same region (2007-08) and no alarming differences were observed in the pollutant levels. Our observations are discussed in the light of current understanding of pollutants sources over this region.

  8. Mitigation of Grid-Current Distortion for LCL-Filtered Voltage-Source Inverter with Inverter-Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...

  9. Methylobacterium genome sequences: a reference blueprint to investigate microbial metabolism of C1 compounds from natural and industrial sources.

    Science.gov (United States)

    Vuilleumier, Stéphane; Chistoserdova, Ludmila; Lee, Ming-Chun; Bringel, Françoise; Lajus, Aurélie; Zhou, Yang; Gourion, Benjamin; Barbe, Valérie; Chang, Jean; Cruveiller, Stéphane; Dossat, Carole; Gillett, Will; Gruffaz, Christelle; Haugen, Eric; Hourcade, Edith; Levy, Ruth; Mangenot, Sophie; Muller, Emilie; Nadalig, Thierry; Pagni, Marco; Penny, Christian; Peyraud, Rémi; Robinson, David G; Roche, David; Rouy, Zoé; Saenampechek, Channakhone; Salvignol, Grégory; Vallenet, David; Wu, Zaining; Marx, Christopher J; Vorholt, Julia A; Olson, Maynard V; Kaul, Rajinder; Weissenbach, Jean; Médigue, Claudine; Lidstrom, Mary E

    2009-01-01

    Methylotrophy describes the ability of organisms to grow on reduced organic compounds without carbon-carbon bonds. The genomes of two pink-pigmented facultative methylotrophic bacteria of the Alpha-proteobacterial genus Methylobacterium, the reference species Methylobacterium extorquens strain AM1 and the dichloromethane-degrading strain DM4, were compared. The 6.88 Mb genome of strain AM1 comprises a 5.51 Mb chromosome, a 1.26 Mb megaplasmid and three plasmids, while the 6.12 Mb genome of strain DM4 features a 5.94 Mb chromosome and two plasmids. The chromosomes are highly syntenic and share a large majority of genes, while plasmids are mostly strain-specific, with the exception of a 130 kb region of the strain AM1 megaplasmid which is syntenic to a chromosomal region of strain DM4. Both genomes contain large sets of insertion elements, many of them strain-specific, suggesting an important potential for genomic plasticity. Most of the genomic determinants associated with methylotrophy are nearly identical, with two exceptions that illustrate the metabolic and genomic versatility of Methylobacterium. A 126 kb dichloromethane utilization (dcm) gene cluster is essential for the ability of strain DM4 to use DCM as the sole carbon and energy source for growth and is unique to strain DM4. The methylamine utilization (mau) gene cluster is only found in strain AM1, indicating that strain DM4 employs an alternative system for growth with methylamine. The dcm and mau clusters represent two of the chromosomal genomic islands (AM1: 28; DM4: 17) that were defined. The mau cluster is flanked by mobile elements, but the dcm cluster disrupts a gene annotated as chelatase and for which we propose the name "island integration determinant" (iid). These two genome sequences provide a platform for intra- and interspecies genomic comparisons in the genus Methylobacterium, and for investigations of the adaptive mechanisms which allow bacterial lineages to acquire methylotrophic

  10. Modeling of Single Event Transients With Dual Double-Exponential Current Sources: Implications for Logic Cell Characterization

    Science.gov (United States)

    Black, Dolores A.; Robinson, William H.; Wilcox, Ian Z.; Limbrick, Daniel B.; Black, Jeffrey D.

    2015-08-01

    Single event effects (SEE) are a reliability concern for modern microelectronics. Bit corruptions can be caused by single event upsets (SEUs) in the storage cells or by sampling single event transients (SETs) from a logic path. An accurate prediction of soft error susceptibility from SETs requires good models to convert collected charge into compact descriptions of the current injection process. This paper describes a simple, yet effective, method to model the current waveform resulting from a charge collection event for SET circuit simulations. The model uses two double-exponential current sources in parallel, and the results illustrate why a conventional model based on one double-exponential source can be incomplete. A small set of logic cells with varying input conditions, drive strength, and output loading are simulated to extract the parameters for the dual double-exponential current sources. The parameters are based upon both the node capacitance and the restoring current (i.e., drive strength) of the logic cell.

  11. Design considerations for high current regulated DC power supplies with reference to 600 kW variable DC power supply

    International Nuclear Information System (INIS)

    Ushakumari; Garud, A.N.; Nadkarni, S.S.

    1980-01-01

    High current regulated dc power supplies find increasing applications in industry and research. The power rating of these supplies vary from few killowatts to megawatts. The general requirements of these supplies for various applications and the techniques used to achieve the desired performance are presented. The design and selection of various circuit blocks namely the rectifier transformer, multiphase rectifier arrangement, SCR paralleling and current sensing techniques, are discussed in detail for a 600 killowatt current controlled supply developed in the Bhabha Atomic Research Centre, Bombay, and used for the thermal studies of reactor components. The power supply incorporates paralleled phase controlled thyristors with a closed loop feedback circuitary to achieve a current stability of 0.1% and smooth output variation from 10 to 100%. (auth.)

  12. Novel MSVPWM to reduce the inductor current ripple for Z-source inverter in electric vehicle applications.

    Science.gov (United States)

    Zhang, Qianfan; Dong, Shuai; Xue, Ping; Zhou, Chaowei; Cheng, ShuKang

    2014-01-01

    A novel modified space vector pulse width modulation (MSVPWM) strategy for Z-Source inverter is presented. By rearranging the position of shoot-through states, the frequency of inductor current ripple is kept constant. Compared with existing MSVPWM strategies, the proposed approach can reduce the maximum inductor current ripple. So the volume of Z-source network inductor can be designed smaller, which brings the beneficial effect on the miniaturization of the electric vehicle controller. Theoretical findings in the novel MSVPWM for Z-Source inverter have been verified by experiment results.

  13. Study and Analysis of a Natural Reference Frame Current Controller for a Multi-Level H-Bridge Power Converter

    DEFF Research Database (Denmark)

    Ciobotaru, Mihai; Iov, Florin; Zanchetta, P.

    2008-01-01

    will be needed in order to control the power flow and to ensure proper and secure operation of this future grid with an increased level of renewable power. These power converters must be able to provide intelligent power management as well as ancillary services. This paper presents an analysis of the natural...... reference frame controller, based on proportional-resonant (PR) technique, for a multi-level H-bridge power converter for Universal and Flexible Power Management in Future Electricity Network. The proposed method is tested in terms of harmonic content in the Point of Common Coupling (PCC), voltage...

  14. Characteristics of cold atmospheric plasma source based on low-current pulsed discharge with coaxial electrodes

    Science.gov (United States)

    Bureyev, O. A.; Surkov, Yu S.; Spirina, A. V.

    2017-05-01

    This work investigates the characteristics of the gas discharge system used to create an atmospheric pressure plasma flow. The plasma jet design with a cylindrical graphite cathode and an anode rod located on the axis of the system allows to realize regularly reproducible spark breakdowns mode with a frequency ∼ 5 kHz and a duration ∼ 40 μs. The device generates a cold atmospheric plasma flame with 1 cm in diameter in the flow of various plasma forming gases including nitrogen and air at about 100 mA average discharge current. In the described construction the cathode spots of individual spark channels randomly move along the inner surface of the graphite electrode creating the secondary plasma stream time-average distributed throughout the whole exit aperture area after the decay of numerous filamentary discharge channels. The results of the spectral diagnostics of plasma in the discharge gap and in the stream coming out of the source are presented. Despite the low temperature of atoms and molecules in plasma stream the cathode spots operation with temperature of ∼ 4000 °C at a graphite electrode inside a discharge system enables to saturate the plasma by CN-radicals and atomic carbon in the case of using nitrogen as the working gas.

  15. Seasonal Characteristics of Widespread Ozone Pollution in China and India: Current Model Capabilities and Source Attributions

    Science.gov (United States)

    Gao, M.; Song, S.; Beig, G.; Zhang, H.; Hu, J.; Ying, Q.; McElroy, M. B.

    2017-12-01

    Fast urbanization and industrialization in China and India have led to severe ozone pollution, threatening public health in these densely populated countries. We show the spatial and seasonal characteristics of ozone concentrations using nation-wide observations for these two countries in 2013. We used the Weather Research and Forecasting model coupled to chemistry (WRF-Chem) to conduct one-year simulations and to evaluate how current models capture the important photochemical processes using the exhaustive available datasets in China and India, including surface measurements, ozonesonde data and satellite retrievals. We also employed the factor separation approach to distinguish the contributions of different sectors to ozone during different seasons. The back trajectory model FLEXPART was applied to investigate the role of transport in highly polluted regions (e.g., North China Plain, Yangtze River delta, and Pearl River Delta) during different seasons. Preliminary results indicate that the WRF-Chem model provides a satisfactory representation of the temporal and spatial variations of ozone for both China and India. The factor separation approach offers valuable insights into relevant sources of ozone for both countries providing valuable guidance for policy options designed to mitigate the related problem.

  16. Hybrid HVDC (H2VDC System Using Current and Voltage Source Converters

    Directory of Open Access Journals (Sweden)

    José Rafael Lebre

    2018-05-01

    Full Text Available This paper presents an analysis of a new high voltage DC (HVDC transmission system, which is based on current and voltage source converters (CSC and VSC in the same circuit. This proposed topology is composed of one CSC (rectifier and one or more VSCs (inverters connected through an overhead transmission line in a multiterminal configuration. The main purpose of this Hybrid HVDC (H2VDC, as it was designed, is putting together the best benefits of both types of converters in the same circuit: no commutation failure and system’s black start capability in the VSC side, high power converter capability and low cost at the rectifier side, etc. A monopole of the H2VDC system with one CSC and two VSCs—here, the VSC is the Modular Multilevel Converter (MMC considered with full-bridge submodules—in multiterminal configuration is studied. The study includes theoretical analyses, development of the CSC and VSCs control philosophies and simulations. The H2VDC system’s behavior is analyzed by computational simulations considering steady-state operation and short-circuit conditions at the AC and DC side. The obtained results and conclusions show a promising system for very high-power multiterminal HVDC transmission.

  17. Torque harmonics of an asynchronous motor supplied by a voltage- or current-sourced inverter quasi-square operation

    Energy Technology Data Exchange (ETDEWEB)

    Kyyrae, J. [Helsinki University of Technology, Institute of Intelligent Power Electronics, Espoo (Finland)

    1997-12-31

    Voltage- and current-sourced dc-ac converters operating in quasi-square area are compared. Their characteristics are calculated with switching vector, which is space-vector of switching functions. When the load is an asynchronous motor various analytical equations, including torque, are calculated efficiently. Motor current and torque approximations are compared with the simulated ones. (orig.) 6 refs.

  18. A transformerless single-phase symmetrical Z-source HERIC inverter with reduced leakage currents for PV systems

    DEFF Research Database (Denmark)

    Li, Kerui; Shen, Yanfeng; Yang, Yongheng

    2018-01-01

    and thus low leakage currents in PV applications. The symmetric Z-source HERIC inverter requires two extra active switches. Nevertheless, the operation frequency of the two switches is the line frequency, leading to negligible losses. More importantly, the performance in terms of low leakage currents...... and harmonics is improved. Experimental tests are performed to validate the analysis and performance of the proposed system....

  19. Methylobacterium genome sequences: a reference blueprint to investigate microbial metabolism of C1 compounds from natural and industrial sources.

    Directory of Open Access Journals (Sweden)

    Stéphane Vuilleumier

    Full Text Available Methylotrophy describes the ability of organisms to grow on reduced organic compounds without carbon-carbon bonds. The genomes of two pink-pigmented facultative methylotrophic bacteria of the Alpha-proteobacterial genus Methylobacterium, the reference species Methylobacterium extorquens strain AM1 and the dichloromethane-degrading strain DM4, were compared.The 6.88 Mb genome of strain AM1 comprises a 5.51 Mb chromosome, a 1.26 Mb megaplasmid and three plasmids, while the 6.12 Mb genome of strain DM4 features a 5.94 Mb chromosome and two plasmids. The chromosomes are highly syntenic and share a large majority of genes, while plasmids are mostly strain-specific, with the exception of a 130 kb region of the strain AM1 megaplasmid which is syntenic to a chromosomal region of strain DM4. Both genomes contain large sets of insertion elements, many of them strain-specific, suggesting an important potential for genomic plasticity. Most of the genomic determinants associated with methylotrophy are nearly identical, with two exceptions that illustrate the metabolic and genomic versatility of Methylobacterium. A 126 kb dichloromethane utilization (dcm gene cluster is essential for the ability of strain DM4 to use DCM as the sole carbon and energy source for growth and is unique to strain DM4. The methylamine utilization (mau gene cluster is only found in strain AM1, indicating that strain DM4 employs an alternative system for growth with methylamine. The dcm and mau clusters represent two of the chromosomal genomic islands (AM1: 28; DM4: 17 that were defined. The mau cluster is flanked by mobile elements, but the dcm cluster disrupts a gene annotated as chelatase and for which we propose the name "island integration determinant" (iid.These two genome sequences provide a platform for intra- and interspecies genomic comparisons in the genus Methylobacterium, and for investigations of the adaptive mechanisms which allow bacterial lineages to acquire

  20. Open Access, Open Source and Digital Libraries: A Current Trend in University Libraries around the World

    Science.gov (United States)

    Krishnamurthy, M.

    2008-01-01

    Purpose: The purpose of this paper is to describe the open access and open source movement in the digital library world. Design/methodology/approach: A review of key developments in the open access and open source movement is provided. Findings: Open source software and open access to research findings are of great use to scholars in developing…

  1. Overview of current peculiarities of promotion of energy from renewable sources in Lithuania. Country reports: Lithuania

    OpenAIRE

    Griguolaitė, Rita

    2015-01-01

    This report provides an overview of the legal background and strategic planning of development and promotion of energy from renewable sources in Lithuania. It discusses the main provisions of the Law on Energy from Renewable Sources in the sectors of electricity, transport and heat. Also, established national financial incentives for the promotion of energy from renewable sources are described.

  2. Characterization of dynamic changes of current source localization based on spatiotemporal fMRI constrained EEG source imaging

    Science.gov (United States)

    Nguyen, Thinh; Potter, Thomas; Grossman, Robert; Zhang, Yingchun

    2018-06-01

    Objective. Neuroimaging has been employed as a promising approach to advance our understanding of brain networks in both basic and clinical neuroscience. Electroencephalography (EEG) and functional magnetic resonance imaging (fMRI) represent two neuroimaging modalities with complementary features; EEG has high temporal resolution and low spatial resolution while fMRI has high spatial resolution and low temporal resolution. Multimodal EEG inverse methods have attempted to capitalize on these properties but have been subjected to localization error. The dynamic brain transition network (DBTN) approach, a spatiotemporal fMRI constrained EEG source imaging method, has recently been developed to address these issues by solving the EEG inverse problem in a Bayesian framework, utilizing fMRI priors in a spatial and temporal variant manner. This paper presents a computer simulation study to provide a detailed characterization of the spatial and temporal accuracy of the DBTN method. Approach. Synthetic EEG data were generated in a series of computer simulations, designed to represent realistic and complex brain activity at superficial and deep sources with highly dynamical activity time-courses. The source reconstruction performance of the DBTN method was tested against the fMRI-constrained minimum norm estimates algorithm (fMRIMNE). The performances of the two inverse methods were evaluated both in terms of spatial and temporal accuracy. Main results. In comparison with the commonly used fMRIMNE method, results showed that the DBTN method produces results with increased spatial and temporal accuracy. The DBTN method also demonstrated the capability to reduce crosstalk in the reconstructed cortical time-course(s) induced by neighboring regions, mitigate depth bias and improve overall localization accuracy. Significance. The improved spatiotemporal accuracy of the reconstruction allows for an improved characterization of complex neural activity. This improvement can be

  3. Nuclear and isotopic techniques for addressing nutritional problems, with special reference to current applications in developing countries.

    Science.gov (United States)

    Iyengar, Venkatesh

    2002-03-01

    Nuclear and isotopic techniques are valuable tools in human nutritional research studies. Isotopes, both radioactive and nonradioactive, enable detailed evaluations of nutrient intake, body composition, energy expenditure, status of micronutrients, and nutrient bioavailability. In recent times, isotopic methods have been widely used in a number of coordinated research projects and technical cooperation projects of the International Atomic Energy Agency's Nutrition Programme. The doubly labeled water technique combines the use of the stable isotopes oxygen-18 and hydrogen-2 (deuterium) to measure total energy expenditure in free-living human subjects, and to investigate the magnitude and causes of both undernutrition and the emergence of obesity in developing countries. The deuterium dilution technique is a reliable tool to measure breastmilk intake and thereby infant growth and development. In collaboration with the World Health Organization's Growth Monitoring Program, this technique is being used to generate new data on growth standards for children in developing countries. This technique is also used in the measurement of body composition by the estimation of lean body mass and fat mass in individuals. Stable isotopes of iron and zinc have been successfully used to assess the nutritional impact of several nationwide food supplementation-programs conducted on pregnant and lactating women and children in both industrialized and developing countries. Isotopic techniques are especially suitable for monitoring changes in body composition, energy metabolism, and mineral status (with particular reference to osteoporosis) in the elderly. Nuclear methods have also served to develop models for a physiological reference man in Asia in support of radiological health and safety issues, for establishing elemental composition of foods, and for measurement of pollutants in the environment.

  4. An improved synchronous reference frame current control strategy for a photovoltaic grid-connected inverter under unbalanced and nonlinear load conditions

    DEFF Research Database (Denmark)

    Naderipour, Amirreza; Asuhaimi Mohd Zin, Abdullah; Bin Habibuddin, Mohd Hafiz

    2017-01-01

    In recent years, renewable energy sources have been considered the most encouraging resources for grid and off-grid power generation. This paper presents an improved current control strategy for a three-phase photovoltaic grid-connected inverter (GCI) under unbalanced and nonlinear load conditions....... It is challenging to suppress the harmonic content in the output current below a pre-set value in the GCI. It is also difficult to compensate for unbalanced loads even when the grid is under disruption due to total harmonic distortion (THD) and unbalanced loads. The primary advantage and objective of this method...... is to effectively compensate for the harmonic current content of the grid current and microgrid without the use of any compensation devices, such as active and passive filters. This method leads to a very low THD in both the GCI currents and the current exchanged with the grid. The control approach is designed...

  5. Is popular radio a source of exposure to alcohol references in mid to later life? A content analysis.

    Science.gov (United States)

    Haighton, C; Halligan, J; Scott, S

    2017-04-20

    There is concern around alcohol consumption in mid to later life yet little understanding about what influences this behaviour. No previous research has explored the extent to which adults in mid to later life may be exposed to alcohol references in the media. This project aimed to determine the frequency of alcohol references on radio stations with a high proportion of listeners in mid to later life. Content analysis of alcohol references on four popular UK music-based radio stations with a high proportion of listeners aged 55-64 years over three time points. Alcohol references occur frequently, but vary by time of year and type of radio station. When alcohol is mentioned its consumption is portrayed as the norm, without negative consequences. On three commercial stations, the majority of mentions came from advertising, whereas on BBC Radio 2 nearly all references were talk-based. All adverts for direct promotion of alcohol were by supermarkets. Alcohol was frequently associated with celebrations, socializing or something to consume for its own sake. Adults in the age group 55-64 may be exposed to references to alcohol that could serve to reinforce norms of consumption of alcohol and promote purchases of cheap alcohol. © The Author 2017. Published by Oxford University Press on behalf of Faculty of Public Health. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  6. EEG current source density and the phenomenology of the default network.

    Science.gov (United States)

    Cannon, Rex L; Baldwin, Debora R

    2012-10-01

    In recent years, there has been an increasing line of research dedicated to the investigation of the default mode network (DMN) of the brain and resting state networks. However, the mental activity of the DMN has not been rigorously assessed to date. The specific aims of the current study were 2-fold: First, we sought to determine whether the current source density (CSD) levels in the DMN would correspond to other neuroimaging techniques. Second, we sought to understand the subjective mental activity of the DMN during baseline recordings. This study was conducted with 63 nonclinical participants, 34 female and 29 males with a mean age of 19.2 years (standard deviation = 2.0). The participants were recorded in 8 conditions. First, 4-minute eyes-closed baseline (ECB) and eyes-opened baseline (EOB) were obtained. The participants then completed 3 assessment instruments and 3 image conditions while the electroencephalography (EEG) was continuously recorded. Participants completed subjective reports for baselines and image conditions. These were rated by 3 independent raters and compared for reliability using a random effects model with an absolute agreement definition. The mean CSD between all conditions differed significantly, in many but not all regions of interest in the DMN. Interestingly, as suggested by other studies, the DMN appears preferential to self-relevant, self-specific, or self-perceptive processes. The reliability analyses show α for interrater agreement for ECB at .95 and EOB at .96. The subjective reports obtained from the participants regarding the mental activities employed during baseline recordings correspond to attentional and self-regulatory processes, which may also implicate the resting state or DMN as playing a direct role in the maintenance of a complex behavior (eg, being still, attending, and self-regulating). Thus, attention and self-regulation constitute the phenomenology of the resting state (DMN) in this study. The results also

  7. Radiochemical study of processes of adsorption on the electrodes of chemical sources of current with lithium anodes

    Energy Technology Data Exchange (ETDEWEB)

    Basov, V.P.; Karapetyan, Yu.A.; Krysenko, A.D.; Chuvashkin, A.N.; Rogachev, Yu.A.

    1985-04-01

    Labeled compounds are used to study the kinetics of formation of adsorption films on the electrodes on an Li-SOCL/sub 2/ current source containing a lithium tetrachloroaluminate electrolyte. Experiments were performed in a glass cell in which lithium and graphite electrodes with an area of 1 square centimeter were suspended. The kinetics of film formation in pure SOCl/sub 2/ and in LiAlCl/sub 4/ solutions were studied in the concentration range of 0.25 to 1.0 M complex salt. The quantity of chloride and sulfur precipitated on the electrodes during both charging and discharging was determined in the temperature interval from -50 to +50/sup 0/C. The kinetics of precipitation of chlorine and sulfur on the electrodes during charging showed that the elements are adsorbed only on the lithium electrode. Chlorine is precipitated as the maximum rate during the first one or two hours, and slows down but does not stop even after one hundred hours. Adsorption of chlorine increases with increasing LiAlCl/sub 4/ concentration. Adsorption of sulfur on the lithium electrode is significantly less, but increases with an increase in salt concentration. At -50 to +25/sup 0/C there is a slight increase in the quantity of adsorbed chlorine and a decrease in adsorption of sulfur with increasing temperature. Significant changes occur only at temperatures above 25/sup 0/C. During discharging the quantity of chlorine and sulfur in the precipitate on the lithium anode remains practically unchanged. On the graphite cathode during discharging there is significant adsorption of chlorine proportional to the quantity of electricity passing through the solution. 4 references, 4 figures.

  8. 3-D time-domain induced polarization tomography: a new approach based on a source current density formulation

    Science.gov (United States)

    Soueid Ahmed, A.; Revil, A.

    2018-04-01

    Induced polarization (IP) of porous rocks can be associated with a secondary source current density, which is proportional to both the intrinsic chargeability and the primary (applied) current density. This gives the possibility of reformulating the time domain induced polarization (TDIP) problem as a time-dependent self-potential-type problem. This new approach implies a change of strategy regarding data acquisition and inversion, allowing major time savings for both. For inverting TDIP data, we first retrieve the electrical resistivity distribution. Then, we use this electrical resistivity distribution to reconstruct the primary current density during the injection/retrieval of the (primary) current between the current electrodes A and B. The time-lapse secondary source current density distribution is determined given the primary source current density and a distribution of chargeability (forward modelling step). The inverse problem is linear between the secondary voltages (measured at all the electrodes) and the computed secondary source current density. A kernel matrix relating the secondary observed voltages data to the source current density model is computed once (using the electrical conductivity distribution), and then used throughout the inversion process. This recovered source current density model is in turn used to estimate the time-dependent chargeability (normalized voltages) in each cell of the domain of interest. Assuming a Cole-Cole model for simplicity, we can reconstruct the 3-D distributions of the relaxation time τ and the Cole-Cole exponent c by fitting the intrinsic chargeability decay curve to a Cole-Cole relaxation model for each cell. Two simple cases are studied in details to explain this new approach. In the first case, we estimate the Cole-Cole parameters as well as the source current density field from a synthetic TDIP data set. Our approach is successfully able to reveal the presence of the anomaly and to invert its Cole

  9. Linear surface photoelectric effect of gold in intense laser field as a possible high-current electron source

    International Nuclear Information System (INIS)

    Farkas, G.; Horvath, Z.G.; Toth, C.; Fotakis, C.; Hontzopoulos, E.

    1987-01-01

    Investigations were conducted on radiation-induced electron emission processes on a gold target surface with a high-intensity (2 MW/cm 2 ) KrF laser (λ = 248 nm). The single photon surface photoelectric emission obtained can be used for high-current density electron sources. The measured polarization dependence of electron current shows the dominance of the surface-type effect over that of the volume type, thereby making it possible to optimize the short, high-density electron current creation conditions. The advantage of the grazing light incidence and the multiphoton photoeffect giving rise to a 500 A/cm 2 electron current has been demonstrated

  10. An image-based skeletal dosimetry model for the ICRP reference adult male-internal electron sources

    International Nuclear Information System (INIS)

    Hough, Matthew; Johnson, Perry; Bolch, Wesley; Rajon, Didier; Jokisch, Derek; Lee, Choonsik

    2011-01-01

    In this study, a comprehensive electron dosimetry model of the adult male skeletal tissues is presented. The model is constructed using the University of Florida adult male hybrid phantom of Lee et al (2010 Phys. Med. Biol. 55 339-63) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow, associated with radiogenic leukemia, and total shallow marrow, associated with radiogenic bone cancer. Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following sources: bone marrow (active and inactive), trabecular bone (surfaces and volumes), and cortical bone (surfaces and volumes). Specific absorbed fractions are computed according to the MIRD schema, and are given as skeletal-averaged values in the paper with site-specific values reported in both tabular and graphical format in an electronic annex available from http://stacks.iop.org/0031-9155/56/2309/mmedia. The distribution of cortical bone and spongiosa at the macroscopic dimensions of the phantom, as well as the distribution of trabecular bone and marrow tissues at the microscopic dimensions of the phantom, is imposed through detailed analyses of whole-body ex vivo CT images (1 mm resolution) and spongiosa-specific ex vivo microCT images (30 μm resolution), respectively, taken from a 40 year male cadaver. The method utilized in this work includes: (1) explicit accounting for changes in marrow self-dose with variations in marrow cellularity, (2) explicit accounting for electron escape from spongiosa, (3) explicit consideration of spongiosa cross-fire from cortical bone, and (4) explicit consideration of the ICRP's change in the surrogate tissue region defining the location of the osteoprogenitor cells (from a 10 μm endosteal layer covering the trabecular and cortical surfaces to a 50 μm shallow marrow layer covering trabecular and medullary cavity surfaces). Skeletal

  11. An image-based skeletal dosimetry model for the ICRP reference adult male-internal electron sources

    Energy Technology Data Exchange (ETDEWEB)

    Hough, Matthew; Johnson, Perry; Bolch, Wesley [Department of Nuclear and Radiological Engineering, University of Florida, Gainesville, FL (United States); Rajon, Didier [Department of Neurosurgery, University of Florida, Gainesville, FL (United States); Jokisch, Derek [Department of Physics and Astronomy, Francis Marion University, Florence, SC (United States); Lee, Choonsik, E-mail: wbolch@ufl.edu [Radiation Epidemiology Branch, National Cancer Institute, Bethesda, MD (United States)

    2011-04-21

    In this study, a comprehensive electron dosimetry model of the adult male skeletal tissues is presented. The model is constructed using the University of Florida adult male hybrid phantom of Lee et al (2010 Phys. Med. Biol. 55 339-63) and the EGSnrc-based Paired Image Radiation Transport code of Shah et al (2005 J. Nucl. Med. 46 344-53). Target tissues include the active bone marrow, associated with radiogenic leukemia, and total shallow marrow, associated with radiogenic bone cancer. Monoenergetic electron emissions are considered over the energy range 1 keV to 10 MeV for the following sources: bone marrow (active and inactive), trabecular bone (surfaces and volumes), and cortical bone (surfaces and volumes). Specific absorbed fractions are computed according to the MIRD schema, and are given as skeletal-averaged values in the paper with site-specific values reported in both tabular and graphical format in an electronic annex available from http://stacks.iop.org/0031-9155/56/2309/mmedia. The distribution of cortical bone and spongiosa at the macroscopic dimensions of the phantom, as well as the distribution of trabecular bone and marrow tissues at the microscopic dimensions of the phantom, is imposed through detailed analyses of whole-body ex vivo CT images (1 mm resolution) and spongiosa-specific ex vivo microCT images (30 {mu}m resolution), respectively, taken from a 40 year male cadaver. The method utilized in this work includes: (1) explicit accounting for changes in marrow self-dose with variations in marrow cellularity, (2) explicit accounting for electron escape from spongiosa, (3) explicit consideration of spongiosa cross-fire from cortical bone, and (4) explicit consideration of the ICRP's change in the surrogate tissue region defining the location of the osteoprogenitor cells (from a 10 {mu}m endosteal layer covering the trabecular and cortical surfaces to a 50 {mu}m shallow marrow layer covering trabecular and medullary cavity surfaces). Skeletal

  12. To implement REX today: why? How? References for an event-related return on experience as a source of learning

    International Nuclear Information System (INIS)

    Bringaud, Violaine; Fayolle, Patrice; Madec, Veronique; Gauthereau, Vincent; Raud, Geraldine; Hernandez, Guillaume; Vautier, Jean-Francois; Le Roy, Guilhem; Maffre, Jean-Francois; Pichancourt, Isabelle; Rousseau, Jean-Marie

    2014-01-01

    The REX (Return on Experience) is an arrangement which is supposed to allow lessons to be learned from dysfunctions occurring during activities in nuclear installations. This report, written by a work group, proposes a synthesis of some references regarding REX arrangements, and aims at deepening the discussion and at the evolution of these arrangements. It presents the different components of a REX arrangement, and outlines its operational objectives: to understand, to share and to act. It highlights the conditions for an efficient REX arrangement: definition of an event, analysis methods, analysis abilities, management approaches, corrective actions, and so on. It indicates how to use this document and some useful references

  13. Current Research on Molasses as an Alternative Energy Source for Organic Dairy Herds

    Science.gov (United States)

    As organic grain prices have increased and organic milk prices have decreased, dairy farmers are seeking lower-cost supplementation strategies. Sugarcane molasses, a rich source of sucrose, seems to be a viable option as a source of energy. Molasses frequently costs less per pound of dry matter than...

  14. High Current, High Density Arc Plasma as a New Source for WiPAL

    Science.gov (United States)

    Waleffe, Roger; Endrizzi, Doug; Myers, Rachel; Wallace, John; Clark, Mike; Forest, Cary; WiPAL Team

    2016-10-01

    The Wisconsin Plasma Astrophysics Lab (WiPAL) has installed a new array of nineteen plasma sources (plasma guns) on its 3 m diameter, spherical vacuum vessel. Each gun is a cylindrical, molybdenum, washer-stabilized, arc plasma source. During discharge, the guns are maintained at 1.2 kA across 100 V for 10 ms by the gun power supply establishing a high density plasma. Each plasma source is fired independently allowing for adjustable plasma parameters, with densities varying between 1018 -1019 m-3 and electron temperatures of 5-15 eV. Measurements were characterized using a 16 tip Langmuir probe. The plasma source will be used as a background plasma for the magnetized coaxial plasma gun (MCPG), the Terrestrial Reconnection Experiment (TREX), and as the plasma source for a magnetic mirror experiment. Temperature, density, and confinement results will be presented. This work is supported by the DoE and the NSF.

  15. Science education with the help of media. Educating science concerning the help of current news of media referring to it

    International Nuclear Information System (INIS)

    Lazar, I.; Agoston, L.

    2005-01-01

    In the last decades, at the beginning of the 21st century high school students turn their back on science more frequently than before, therefore the generation of the community of reliable scientists and experts becomes the elder. The time spent studying science in schools is also decreasing. However, mass-communication, electronic and traditional media plays more and more part in the description and explanation of scientific problems in our time. Media is inundated with questions, facts and rumours in connection with science, therefore imaginary fears, beliefs and superstitions can get into the limelight of interests. Problems like keeping people frightened with radioactivity and the ionizing and non-ionizing radiations is probably the most popular way of making ''bad news'' (panic) in the mass-media, and they particularly call our attention to the most current tasks in education of the next generations. In order to help to keep the public informed in a precise and exact way, it's necessary to put natural science into practice in high schools. Our new method of science education could prove the necessity of science taught through the current news of the media. This means students learn by making discussions and corrections of the news. The Science and Media Project provides the possibility of applying scientific ways of thinking about questions of our environment and life and it also improves critical approach towards new information. This method is put to practice by real project works, including a lot of fieldwork and reading of papers and scientific literature, enabling the students to discover and solve problems by themselves. (author)

  16. Fixed speed wind farm operation improvement using current-source converter based UPQC

    International Nuclear Information System (INIS)

    Ajami, Ali; Armaghan, Mehdi

    2012-01-01

    Highlights: ► Reactive power and voltage sag are compensated during grid side fault. ► Nonlinear model of UPQC is modified to a linear model. ► Using the CSI in proposed UPQC offers a number of distinct advantages. ► Pitch angle controller is used to obtain nominal power at high wind speeds. ► Optimal control method (LQR) is used to determine the optimal state feedback gains. - Abstract: In this paper, a current-source converter based unified power quality conditioner (UPQC) is used for the flexible integration of pitch controlled fixed speed wind generator (FSWG) to IEEE 13 node test feeder. During the normal operation, shunt compensator (SHUC) of the UPQC maintains a unity power factor condition at the Point of Common Coupling (PCC) and when a voltage sag occurs due to grid side fault the series compensator (SERC) of the UPQC injects appropriate deficit voltage to prevent disconnecting of the FSWG and the SHUC of the UPQC provides additional reactive power in fault during. The pitch angle is controlled in order to limit the generator output power to its nominal value for high wind speeds. The nonlinear model of the shunt compensator of the UPQC is modified to a linear model. The modeling technique is not based on the linearization of a set of nonlinear equations around an operating point. Instead, the power balance equation and a nonlinear input transformation are used to derive a linear model independent of the operating point. This model acts as the basis for the design of a decoupled state-feedback controller. The optimal control method linear quadratic regulator (LQR) is used to determine the optimal state-feedback gain matrix. The proposed control approach becomes a robust strategy that is able to keep regulation and stability even under extreme load power factor variations. The In-phase voltage injection method is used for the series compensator of the UPQC. The simulation results carried out by MATLAB/SIMULINK software show the performance of the

  17. Effect of high energy electrons on H⁻ production and destruction in a high current DC negative ion source for cyclotron.

    Science.gov (United States)

    Onai, M; Etoh, H; Aoki, Y; Shibata, T; Mattei, S; Fujita, S; Hatayama, A; Lettry, J

    2016-02-01

    Recently, a filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In this study, numerical modeling of the filament arc-discharge source plasma has been done with kinetic modeling of electrons in the ion source plasmas by the multi-cusp arc-discharge code and zero dimensional rate equations for hydrogen molecules and negative ions. In this paper, main focus is placed on the effects of the arc-discharge power on the electron energy distribution function and the resultant H(-) production. The modelling results reasonably explains the dependence of the H(-) extraction current on the arc-discharge power in the experiments.

  18. Designing high-order power-source synchronous current converters for islanded and grid-connected microgrids

    DEFF Research Database (Denmark)

    Ashabani, Mahdi; Gooi, Hoay Beng; Guerrero, Josep M.

    2018-01-01

    This paper deals with development of a versatile and compact control strategy for voltage source converters in grid-connected and islanded microgrids using synchronous current converters technology. The key feature is its new integrated high-order controller/synchronizer with applicability to both...... and automated current-based grid synchronization. Moreover, the controller realizes a power-source current-controlled microgrid with minimum control loops, as compared to widely adopted voltage controlled microgrids in the literature, with advantages such as fault-ride-through and inherent droop-less power...... sharing capabilities. Adaptive current-based synchronization and smooth switching to islanding mode provides high flexibility, reliability and only-plug operation capability. Extensive simulation and experimental results are presented to demonstrate performance of the proposed control and management...

  19. Subthreshold Current and Swing Modeling of Gate Underlap DG MOSFETs with a Source/Drain Lateral Gaussian Doping Profile

    Science.gov (United States)

    Singh, Kunal; Kumar, Sanjay; Goel, Ekta; Singh, Balraj; Kumar, Mirgender; Dubey, Sarvesh; Jit, Satyabrata

    2017-01-01

    This paper proposes a new model for the subthreshold current and swing of the short-channel symmetric underlap ultrathin double gate metal oxide field effect transistors with a source/drain lateral Gaussian doping profile. The channel potential model already reported earlier has been utilized to formulate the closed form expression for the subthreshold current and swing of the device. The effects of the lateral straggle and geometrical parameters such as the channel length, channel thickness, and oxide thickness on the off current and subthreshold slope have been demonstrated. The devices with source/drain lateral Gaussian doping profiles in the underlap structure are observed to be highly resistant to short channel effects while improving the current drive. The proposed model is validated by comparing the results with the numerical simulation data obtained by using the commercially available ATLAS™, a two-dimensional (2-D) device simulator from SILVACO.

  20. Comment on 'Effects of Magnetic Field Gradient on Ion Beam Current in Cylindrical Hall Ion Source

    International Nuclear Information System (INIS)

    Raitses, Y.; Smirnov A.; Fisch, N.J.

    2008-01-01

    It is argued that the key difference of the cylindrical Hall thruster (CHT) as compared to the end-Hall ion source cannot be exclusively attributed to the magnetic field topology [Tang et al. J. Appl. Phys., 102, 123305 (2007)]. With a similar mirror-type topology, the CHT configuration provides the electric field with nearly equipotential magnetic field surfaces and a better suppression of the electron cross-field transport, as compared to both the end-Hall ion source and the cylindrical Hall ion source of Tang et al

  1. Analog integrated circuit of a low level high voltage current source with capacitive load compensation

    OpenAIRE

    Öner, Mustafa Ertuğrul

    1997-01-01

    Ankara : Department of Electrical and Electronics Engineering and the Institute of Engineering and Sciences of Bilkent University, 1997. Thesis (Master's) -- Bilkent University, 1997. Includes bibliographical references leaves 77-79. Öner, Mustafa Ertuğrul M.S.

  2. Active control of flying capacitor currents in multilevel voltage-source inverters

    Czech Academy of Sciences Publication Activity Database

    Kokeš, Petr; Semerád, Radko

    2013-01-01

    Roč. 58, č. 4 (2013), s. 393-410 ISSN 0001-7043 Institutional support: RVO:61388998 Keywords : voltage source inverter (VSI) * multilevel inverter * flying capacitor Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering

  3. Partitioning and transmutation. Current developments - 2010. A report from the Swedish reference group for PT-research

    Energy Technology Data Exchange (ETDEWEB)

    Blomgren, Jan (ed.) (Swedish Centre for Nuclear Technology, SKC, Stockholm (Sweden)); Karlsson, Fred (Swedish Nuclear Fuel and Waste Management Co., Stockholm (Sweden)); Pomp, Stephan (Uppsala Univ., Uppsala, Dept. of Physics and Astronomy, Div. of Applied Nuclear Physics (Sweden)); Aneheim, Emma; Ekberg, Christian; Fermvik, Anna; Skarnemark, Gunnar (Nuclear Chemistry, Dept. of Chemical and Biological Engineering, Chalmers Univ. of Technology, Goeteborg (Sweden)); Wallenius, Janne; Zakova, Jitka (Reactor Physics Div., Physics Dept., Royal Inst. of Technology, Stockholm (Sweden)); Grenthe, Ingemar; Szabo, Zoltan (School of Chemical Science and Engineering, Royal Inst. of Technology, Stockholm (Sweden))

    2010-01-15

    The research and development on methods for partitioning and transmutation (P and T) of long-lived radionuclides in spent nuclear fuel has attracted considerable interest during the last decade. The main objective of P and T is to eliminate or at least substantially reduce the amount of such long-lived radionuclides that has to go to a deep geological repository for final disposal. The objective of current research on partitioning is to find and develop processes suitable for separation of the heavier actinides (and possibly some long-lived fission products) on an industrial scale. The objective of current research on transmutation is to define, investigate and develop facilities that may be suitable for transmutation of the long-lived radionuclides. The research on partitioning has made important progress in recent years. In some cases one has succeeded to separate americium and curium. Many challenges remain however. Within hydrochemistry one has achieved sufficiently good distribution and separation factors. The focus turns now towards development of an operating process. The search for ligands that give sufficiently good extraction and separation will continue but with less intensity. The emphasis will rather be on improving stability against hydrolysis and radiolysis. This may be achieved either by additives to the solvent or by selection of a proper solvent. The development of processes and equipment must be intensified. Pyrochemical research is looking into methods for recovery of uranium and for separating fission products with large neutron cross sections. The objective is to avoid separation of plutonium from other transuranium elements and thus simplify the proliferation issue. The future work is focused on improved selectivity and on technical development. Design of processes and equipment is difficult due to the aggressive properties of the melts and the relatively high temperatures required. The fabrication of fuel for transmutation and the

  4. Partitioning and transmutation. Current developments - 2010. A report from the Swedish reference group for PT-research

    International Nuclear Information System (INIS)

    Blomgren, Jan; Karlsson, Fred; Pomp, Stephan; Aneheim, Emma; Ekberg, Christian; Fermvik, Anna; Skarnemark, Gunnar; Wallenius, Janne; Zakova, Jitka; Grenthe, Ingemar; Szabo, Zoltan

    2010-01-01

    The research and development on methods for partitioning and transmutation (P and T) of long-lived radionuclides in spent nuclear fuel has attracted considerable interest during the last decade. The main objective of P and T is to eliminate or at least substantially reduce the amount of such long-lived radionuclides that has to go to a deep geological repository for final disposal. The objective of current research on partitioning is to find and develop processes suitable for separation of the heavier actinides (and possibly some long-lived fission products) on an industrial scale. The objective of current research on transmutation is to define, investigate and develop facilities that may be suitable for transmutation of the long-lived radionuclides. The research on partitioning has made important progress in recent years. In some cases one has succeeded to separate americium and curium. Many challenges remain however. Within hydrochemistry one has achieved sufficiently good distribution and separation factors. The focus turns now towards development of an operating process. The search for ligands that give sufficiently good extraction and separation will continue but with less intensity. The emphasis will rather be on improving stability against hydrolysis and radiolysis. This may be achieved either by additives to the solvent or by selection of a proper solvent. The development of processes and equipment must be intensified. Pyrochemical research is looking into methods for recovery of uranium and for separating fission products with large neutron cross sections. The objective is to avoid separation of plutonium from other transuranium elements and thus simplify the proliferation issue. The future work is focused on improved selectivity and on technical development. Design of processes and equipment is difficult due to the aggressive properties of the melts and the relatively high temperatures required. The fabrication of fuel for transmutation and the

  5. BIOMASS UTILIZATION AS A RENEVABLE ENERGY SOURCE IN POLISH POWER INDUSTRY – CURRENT STATUS AND PERSPECTIVES

    Directory of Open Access Journals (Sweden)

    Beata Gołuchowska

    2015-06-01

    Full Text Available The depletion of the conventional energy sources, as well as the degradation and pollution of the environment by the exploitation of fossil fuels caused the development of renewable energy sources (RES, including biomass. In Poland, biomass is the most popular renewable energy source, which is closely related to the obligations associated with the membership in the EU. Biomass is the oldest renewable energy source, and its potential, diversity and polymorphism place it over other sources. Besides, the improvement in its parameters, including an increase in its calorific value, resulted in increasing use of biomass as energy source. In the electric power industry biomass is applied in the process of co-combustion with coal. This process may contribute, inter alia, to the reduction in the emissions of carbon, nitrogen and sulfur oxides. The article presents the characteristics of the biomass burned in power boilers of one of the largest Polish power plants, located in Opole Province (Southern Poland. Besides, the impact of biomass on the installation of co-combustion, as well as the advantages and disadvantages of the co-combustion process not only in technological, but also environmental, economic and social aspects were described.

  6. Current Status of the Systematics of Astragalus L. (Fabaceae with Special Reference to the Himalayan Species in India

    Directory of Open Access Journals (Sweden)

    Lal Babu Chaudhary

    2008-12-01

    Full Text Available Astragalus is considered one of the most diverse genera in the family Leguminosae (nom. alt. Fabaceae. Although a large number of works have been carried out on the genus, no monograph is available except some regional accounts and revisions chiefly at sectional level. It may be due to the sheer size of the genus (ca. 3000 spp. and diverse nature, the genus is quite variable in habit and habitats, size of the plants, nature of indumentums, stipules, leaf rachis, types of inflorescence, relative length of petals, pods etc. Usually, genus is divided into eight to ten subgenera and more than 245 sections. In recently conducted molecular phylogenetic studies it has been shown that none of the subgenera and large sections are monophyletic. However, it has been clearly demonstrated that Astragalus is monophyletic except some outlier species. The chromosome numbers are also quite interesting and significant in Astragalus for its phylogenetic studies. There is a strong correlation between its geographic distribution and chromosome numbers. Currently about 80 species have been recorded from India chiefly from the Himalayas. Except some of our recent publications, not much studies have been carried out on the genus in India after 'The Flora of British India'. Astragalus is not of much economic importance, however, some of its species are well known for commercial gum tragacanth production especially in Iran and China. In India, A. candolleanus is a well known drug as ‘Rudanti’ or ‘Rudravanti’used for tuberculosis, skin diseases, coughs and blood purifier. The aim of this article is to review the entire work carried out on Astragalus and to bring out scattered information at one place for better understanding of the subject and to find out the future prospective of the research in India on the genus.

  7. Buck-Boost Current-Source Inverters With Diode-Inductor Network

    DEFF Research Database (Denmark)

    Gao, Feng; Liang, Chao; Loh, Poh Chiang

    2009-01-01

    This paper presents a number of novel currentsource inverters (CSIs) with enhanced current buck-boost capability. By adding a unique diode-inductor network between the inverter circuitry and current-boost elements, the proposed buck-boost CSIs demonstrate a doubling of current-boost capability......, as compared with other recently reported buck-boost CSIs. For controlling the proposed CSIs, two modulation schemes are designed for achieving either optimized harmonic performance or minimized commutation count without influencing the inverter current buck-boost gain. These theoretical findings were...

  8. Differential contribution of Ca2+ sources to day and night BK current activation in the circadian clock.

    Science.gov (United States)

    Whitt, Joshua P; McNally, Beth A; Meredith, Andrea L

    2018-02-05

    Large conductance K + (BK) channels are expressed widely in neurons, where their activation is regulated by membrane depolarization and intracellular Ca 2+ (Ca 2+ i ). To enable this regulation, BK channels functionally couple to both voltage-gated Ca 2+ channels (VGCCs) and channels mediating Ca 2+ release from intracellular stores. However, the relationship between BK channels and their specific Ca 2+ source for particular patterns of excitability is not well understood. In neurons within the suprachiasmatic nucleus (SCN)-the brain's circadian clock-BK current, VGCC current, and Ca 2+ i are diurnally regulated, but paradoxically, BK current is greatest at night when VGCC current and Ca 2+ i are reduced. Here, to determine whether diurnal regulation of Ca 2+ is relevant for BK channel activation, we combine pharmacology with day and night patch-clamp recordings in acute slices of SCN. We find that activation of BK current depends primarily on three types of channels but that the relative contribution changes between day and night. BK current can be abrogated with nimodipine during the day but not at night, establishing that L-type Ca 2+ channels (LTCCs) are the primary daytime Ca 2+ source for BK activation. In contrast, dantrolene causes a significant decrease in BK current at night, suggesting that nighttime BK activation is driven by ryanodine receptor (RyR)-mediated Ca 2+ i release. The N- and P/Q-type Ca 2+ channel blocker ω-conotoxin MVIIC causes a smaller reduction of BK current that does not differ between day and night. Finally, inhibition of LTCCs, but not RyRs, eliminates BK inactivation, but the BK β2 subunit was not required for activation of BK current by LTCCs. These data reveal a dynamic coupling strategy between BK channels and their Ca 2+ sources in the SCN, contributing to diurnal regulation of SCN excitability. © 2018 Whitt et al.

  9. Low-Cost Open-Source Voltage and Current Monitor for Gas Metal Arc Weld 3D Printing

    Directory of Open Access Journals (Sweden)

    A. Pinar

    2015-01-01

    Full Text Available Arduino open-source microcontrollers are well known in sensor applications for scientific equipment and for controlling RepRap 3D printers. Recently low-cost open-source gas metal arc weld (GMAW RepRap 3D printers have been developed. The entry-level welders used have minimal controls and therefore lack any real-time measurement of welder voltage or current. The preliminary work on process optimization of GMAW 3D printers requires a low-cost sensor and data logger system to measure welder current and voltage. This paper reports on the development of a low-cost open-source power measurement sensor system based on Arduino architecture. The sensor system was designed, built, and tested with two entry-level MIG welders. The full bill of materials and open source designs are provided. Voltage and current were measured while making stepwise adjustments to the manual voltage setting on the welder. Three conditions were tested while welding with steel and aluminum wire on steel substrates to assess the role of electrode material, shield gas, and welding velocity. The results showed that the open source sensor circuit performed as designed and could be constructed for <$100 in components representing a significant potential value through lateral scaling and replication in the 3D printing community.

  10. Current mass spectrometry strategies for selenium speciation in dietary sources of high-selenium

    Energy Technology Data Exchange (ETDEWEB)

    Infante, Heidi Goenaga; Hearn, Ruth; Catterick, Tim [LGC Limited, Teddington, Middlesex (United Kingdom)

    2005-06-01

    This document reviews the most relevant mass spectrometry approaches to selenium (Se) speciation in high-Se food supplements in terms of qualitative and quantitative Se speciation and Se-containing species identification, with special reference to high-Se yeast, garlic, onions and Brazil nuts. Important topics such as complexity of Se speciation in these materials and the importance of combining Se-specific detection and molecule-specific determination of the particular species of this element in parallel with chromatography, to understand their nutritional role and cancer preventive properties are critically discussed throughout. The versatility and potential of mass spectrometric detection in this field are clearly demonstrated. Although great advances have been achieved, further developments are required, especially if ''speciated''certified reference materials (CRMs) are to be produced for validation of measurements of target Se-containing species in Se-food supplements. (orig.)

  11. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    International Nuclear Information System (INIS)

    Haseroth, Helmut; Hora, Heinrich; Regensburg Inst. of Tech.

    1996-01-01

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10 11 C 4+ ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ''hot'' electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author)

  12. Physical mechanisms leading to high currents of highly charged ions in laser-driven ion sources

    Energy Technology Data Exchange (ETDEWEB)

    Haseroth, Helmut [European Organization for Nuclear Research, Geneva (Switzerland); Hora, Heinrich [New South Wales Univ., Kensington, NSW (Australia)]|[Regensburg Inst. of Tech. (Germany). Anwenderzentrum

    1996-12-31

    Heavy ion sources for the big accelerators, for example, the LHC, require considerably more ions per pulse during a short time than the best developed classical ion source, the electron cyclotron resonance (ECR) provides; thus an alternative ion source is needed. This can be expected from laser-produced plasmas, where dramatically new types of ion generation have been observed. Experiments with rather modest lasers have confirmed operation with one million pulses of 1 Hz, and 10{sup 11} C{sup 4+} ions per pulse reached 2 GeV/u in the Dubna synchrotron. We review here the complexities of laser-plasma interactions to underline the unique and extraordinary possibilities that the laser ion source offers. The complexities are elaborated with respect to keV and MeV ion generation, nonlinear (ponderomotive) forces, self-focusing, resonances and ``hot`` electrons, parametric instabilities, double-layer effects, and the few ps stochastic pulsation (stuttering). Recent experiments with the laser ion source have been analyzed to distinguish between the ps and ns interaction, and it was discovered that one mechanism of highly charged ion generation is the electron impact ionization (EII) mechanism, similar to the ECR, but with so much higher plasma densities that the required very large number of ions per pulse are produced. (author).

  13. V-I curves and plasma parameters in a high density DC glow discharge generated by a current-source

    International Nuclear Information System (INIS)

    Granda-Gutierrez, E E; Lopez-Callejas, R; Piedad-Beneitez, A de la; BenItez-Read, J S; Pacheco-Sotelo, J O; Pena-Eguiluz, R; A, R Valencia; Mercado-Cabrera, A; Barocio, S R

    2008-01-01

    Nitrogen DC glow discharges, conducted in a cylindrical geometry, have been characterized using a new current-source able to provide 10 -3 - 3 A for the sustainment of the discharge, instead of a conventional voltage-source. The V-I characteristic curves obtained from these discharges were found to fit the general form i(v) = A(p)v k(p) , whereby the plasma itself can be modeled as a voltage-controlled current-source. We conclude that the fitting parameters A and k, which mainly depend on the gas pressure p, are strongly related to the plasma characteristics, so much so that they can indicate the pressure interval in which the maximum plasma density is located, with values in the order of 10 16 m -3 at reduced discharge potential (300-600 V) and low working pressure (10 -1 - 10 1 Pa)

  14. A Refined Self-Tuning Filter-Based Instantaneous Power Theory Algorithm for Indirect Current Controlled Three-Level Inverter-Based Shunt Active Power Filters under Non-sinusoidal Source Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yap Hoon

    2017-02-01

    Full Text Available In this paper, a refined reference current generation algorithm based on instantaneous power (pq theory is proposed, for operation of an indirect current controlled (ICC three-level neutral-point diode clamped (NPC inverter-based shunt active power filter (SAPF under non-sinusoidal source voltage conditions. SAPF is recognized as one of the most effective solutions to current harmonics due to its flexibility in dealing with various power system conditions. As for its controller, pq theory has widely been applied to generate the desired reference current due to its simple implementation features. However, the conventional dependency on self-tuning filter (STF in generating reference current has significantly limited mitigation performance of SAPF. Besides, the conventional STF-based pq theory algorithm is still considered to possess needless features which increase computational complexity. Furthermore, the conventional algorithm is mostly designed to suit operation of direct current controlled (DCC SAPF which is incapable of handling switching ripples problems, thereby leading to inefficient mitigation performance. Therefore, three main improvements are performed which include replacement of STF with mathematical-based fundamental real power identifier, removal of redundant features, and generation of sinusoidal reference current. To validate effectiveness and feasibility of the proposed algorithm, simulation work in MATLAB-Simulink and laboratory test utilizing a TMS320F28335 digital signal processor (DSP are performed. Both simulation and experimental findings demonstrate superiority of the proposed algorithm over the conventional algorithm.

  15. Determination of plasma spot current and arc discharge plasma current on the system of plasma cathode electron sources using Rogowski coil technique

    International Nuclear Information System (INIS)

    Wirjoadi; Bambang Siswanto; Lely Susita RM; Agus Purwadi; Sudjatmoko

    2015-01-01

    It has been done the function test experiments of ignitor electrode system and the plasma generator electrode system to determine the current spot plasma and arc discharge plasma current with Rogowski coil technique. Ignitor electrode system that gets power supply from IDPS system can generate the plasma spot current of 11.68 ampere to the pulse width of about 33 μs, this value is greater than the design probably because of electronic components used in the IDPS system was not as planned. For the plasma generator electrode system that gets power from ADPS system capable of producing an arc discharge plasma current around 103.15 amperes with a pulse width of about 96 μs, and this value as planned. Based on the value of the arc discharge plasma current can be determined plasma electron density, which is about 10.12 10"1"9 electrons/m"3, and with this electron density value, an ignitor electrode system and a plasma generator system is quite good if used as a plasma cathode electron source system. (author)

  16. Designing display primaries with currently available light sources for UHDTV wide-gamut system colorimetry.

    Science.gov (United States)

    Masaoka, Kenichiro; Nishida, Yukihiro; Sugawara, Masayuki

    2014-08-11

    The wide-gamut system colorimetry has been standardized for ultra-high definition television (UHDTV). The chromaticities of the primaries are designed to lie on the spectral locus to cover major standard system colorimetries and real object colors. Although monochromatic light sources are required for a display to perfectly fulfill the system colorimetry, highly saturated emission colors using recent quantum dot technology may effectively achieve the wide gamut. This paper presents simulation results on the chromaticities of highly saturated non-monochromatic light sources and gamut coverage of real object colors to be considered in designing wide-gamut displays with color filters for the UHDTV.

  17. On supernovae as a source of interstellar dust. The current observational picture

    International Nuclear Information System (INIS)

    Dinerstein, H.L.

    1984-01-01

    Supernovae have been generally thought of as being effective agents for the destruction of ambient interstellar dust. The idea that supernovae may also be a source of dust has been of interest recently, and is attractive for a couple of reasons. The main motivation is to explain meteoritic inclusions with peculiar isotopic abundance ratios as supernova dust condensates predating the solar nebula. In addition, although the nucleation process is not fully understood, the high concentration of condensable elements in the supernova mantle suggests the possibility that grain formation could be very efficient. In this case, supernovae could be a major source of new grain cores to the interstellar medium. (author)

  18. Improvement of bunch-by-bunch beam current detection system in Hefei light source

    International Nuclear Information System (INIS)

    Zheng Kai; Wang Junhua; Liu Zuping; Li Weimin; Zhou Zeran; Yang Yongliang; Huang Longjun; Chen Yuanbo

    2006-01-01

    Bunch-by-bunch beam current detection system is an important facility in the multibunch storage ring. In this paper, the established bunch-by-bunch beam current detection systems for the accelerator such as Cornell, SLAC and KEKB were compared and studied. The design of the bunch-by-bunch beam current detection system for HLS, which was based on the bunch-by-bunch tracing measurement system in HLS was given. Both demodulation by sine wave and square were applied in this paper, the deviation of the detect system was determined by the longitudinal oscillation. Compared the data acquired from ADC with the data from DCCT, the ADC data was scaled by the bunch current. The standard deviations of linear fit were about 1%, and the standard deviations of polynomial fit were less than 0.5% in both sine wave and square wave demodulation. Some analysis of the measurement results also had been shown in this paper. (authors)

  19. Coulomb collisions of ring current particles: Indirect source of heat for the ionosphere

    Science.gov (United States)

    Cole, K. D.

    1975-01-01

    The additional energy requirements of the topside ionosphere during a magnetic storm are less than one quarter of the ring current energy. This energy is supplied largely by Coulomb collisions of ring current protons of energy less than about 20 keV with background thermal electrons which conduct the heat to the ionosphere. Past criticisms are discussed of this mechanism for the supply of energy to the SAR-arc and neighboring regions of the ionosphere.

  20. Bremsstrahlung and Ion Beam Current Measurements with SuSI ECR Ion Source

    International Nuclear Information System (INIS)

    Ropponen, T.

    2012-01-01

    This series of slides presents: the Superconducting Source for Ions (SuSI), the X-ray measurement setup, the different collimation schemes, the flat B operation versus B(min) operation, and the impact of tuning ∇B while keeping fixed field profile

  1. European database on indoor air pollution sources in buildings: Current status of database structure and software

    NARCIS (Netherlands)

    Molina, J.L.; Clausen, G.H.; Saarela, K.; Plokker, W.; Bluyssen, P.M.; Bishop, W.; Oliveira Fernandes, E. de

    1996-01-01

    the European Joule II Project European Data Base for Indoor Air Pollution Sources in Buildings. The aim of the project is to produce a tool which would be used by designers to take into account the actual pollution of the air from the building elements and ventilation and air conditioning system

  2. The design and characteristics of direct current glow discharge atomic emission source operated with plain and hollow cathodes

    International Nuclear Information System (INIS)

    Qayyum, A.; Mahmood, M.I.

    2008-01-01

    A compact direct current glow discharge atomic emission source has been designed and constructed for analytical applications. This atomic emission source works very efficiently at a low-input electrical power. The design has some features that make it distinct from that of the conventional Grimm glow discharge source. The peculiar cathode design offered greater flexibility on size and shape of the sample. As a result the source can be easily adopted to operate in Plain or Hollow Cathode configuration. I-V and spectroscopic characteristics of the source were compared while operating it with plain and hollow copper cathodes. It was observed that with hollow cathode, the source can be operated at a less input power and generates greater Cu I and Cu II line intensities. Also, the intensity of Cu II line rise faster than Cu I line with argon pressure for both cathodes. But the influence of pressure on Cu II lines was more significant when the source is operated with hollow cathode

  3. The position of the individual gods and goddesses in various types of sources - with special reference to the female divinities

    Directory of Open Access Journals (Sweden)

    Else Mundal

    1990-01-01

    Full Text Available In the written sources the gods are arranged in a patriarchal family structure with Odin on the top. If we try to rank the gods in order of precedence on the basis of the number of instances in the toponymic material, Odin would be found a good way down the list. Generally, we should expect gods connected with the cult of fertility and the agricultural society to be overrepresented in the toponymic material in comparison with a god of war. If we consider our literary sources and ask which of the goddesses' names are most frequently used as basic words in kenningar for women, we see that many of the more "unknown" goddesses are very well represented in this material. In the toponymic material, it was the leading goddess who was considered to be the leading god's wife, but not necessarily. Both Frigg and Freyja belong to the type of fertility goddess.

  4. Transformer-based asymmetrical embedded Z-source neutral point clamped inverters with continuous input current and enhanced voltage boost capability

    DEFF Research Database (Denmark)

    Mo, W.; Loh, Poh Chiang; Blaabjerg, Frede

    2013-01-01

    Z-source Neutral Point Clamped (NPC) inverters were introduced to integrate both the advantages of Z-source inverters and NPC inverters. However, traditional Z-source inverters suffer from high voltage stress and chopping input current. This paper proposes six types transformer-based impedance-so......-source NPC inverters which have enhanced voltage boost capability and continuous input current by utilizing of transformer and embedded dc source configuration. Experimental results are presented to verify the theory validation....

  5. Moderator design studies for a new neutron reference source based on the D–T fusion reaction

    International Nuclear Information System (INIS)

    Mozhayev, Andrey V.; Piper, Roman K.; Rathbone, Bruce A.; McDonald, Joseph C.

    2016-01-01

    The radioactive isotope Californium-252 ( 252 Cf) is relied upon internationally as a neutron calibration source for ionizing radiation dosimetry because of its high specific activity. The source may be placed within a heavy-water (D 2 O) moderating sphere to produce a softened spectrum representative of neutron fields common to commercial nuclear power plant environments, among others. Due to termination of the U.S. Department of Energy loan/lease program in 2012, the expense of obtaining 252 Cf sources has undergone a significant increase, rendering high output sources largely unattainable. On the other hand, the use of neutron generators in research and industry applications has increased dramatically in recent years. Neutron generators based on deuteriumtritium (D–T) fusion reaction provide high neutron fluence rates and, therefore, could possibly be used as a replacement for 252 Cf. To be viable, the 14 MeV D–T output spectrum must be significantly moderated to approximate common workplace environments. This paper presents the results of an effort to select appropriate moderating materials and design a configuration to reshape the primary neutron field toward a spectrum approaching that from a nuclear power plant workplace. A series of Monte-Carlo (MCNP) simulations of single layer high- and low-Z materials are used to identify initial candidate moderators. Candidates are refined through a similar series of simulations involving combinations of 2–5 different materials. The simulated energy distribution using these candidate moderators are rated in comparison to a target spectrum. Other properties, such as fluence preservation and/or enhancement, prompt gamma production and other characteristics are also considered. - Highlights: • D–T generator neutron calibration field replacement for D 2 O-moderated 252 Cf. • Determination of representative nuclear power plant workplace neutron spectrum. • Simulations to assess moderating materials to soften 14

  6. A Simple Analytical Model for Predicting the Detectable Ion Current in Ion Mobility Spectrometry Using Corona Discharge Ionization Sources

    Science.gov (United States)

    Kirk, Ansgar Thomas; Kobelt, Tim; Spehlbrink, Hauke; Zimmermann, Stefan

    2018-05-01

    Corona discharge ionization sources are often used in ion mobility spectrometers (IMS) when a non-radioactive ion source with high ion currents is required. Typically, the corona discharge is followed by a reaction region where analyte ions are formed from the reactant ions. In this work, we present a simple yet sufficiently accurate model for predicting the ion current available at the end of this reaction region when operating at reduced pressure as in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) or most IMS-MS instruments. It yields excellent qualitative agreement with measurement results and is even able to calculate the ion current within an error of 15%. Additional interesting findings of this model are the ion current at the end of the reaction region being independent from the ion current generated by the corona discharge and the ion current in High Kinetic Energy Ion Mobility Spectrometers (HiKE-IMS) growing quadratically when scaling down the length of the reaction region. [Figure not available: see fulltext.

  7. Renewable energy sources for the world's poor: a review of current international development assistance programs

    Energy Technology Data Exchange (ETDEWEB)

    Ashworth, J. H.

    1979-10-01

    Foreign assistance funding of the creation, testing, and use of renewable energy sources concerning worldwide efforts to provide energy for Third World development is examined. Donor agencies and developing nations give serious attention to technologies that have been considered exotic and marginal: small-scale hydroelectric generation, solar water heating and distillation, biomass conversion to methane gas and alcohol, wind power, photovoltaic-powered small-scale irrigation, and village-level solar-powered absorption refrigeration. An initial effort to assist in the international coordination of donor activity and in the sharing of information generated by foreign-assistance projects that use renewable energy sources is reported. The report mainly provides information about specific development projects. It contains only a few of the projects that have been approved and funded by 1 June 1979. (MCW)

  8. High ion charge states in a high-current, short-pulse, vacuum ARC ion sources

    International Nuclear Information System (INIS)

    Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.

    1996-01-01

    Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1-4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several μs) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution

  9. High ion charge states in a high-current, short-pulse, vacuum arc ion source

    International Nuclear Information System (INIS)

    Anders, A.; Brown, I.; MacGill, R.; Dickinson, M.

    1995-09-01

    Ions of the cathode material are formed at vacuum arc cathode spots and extracted by a grid system. The ion charge states (typically 1--4) depend on the cathode material and only little on the discharge current as long as the current is low. Here the authors report on experiments with short pulses (several micros) and high currents (several kA); this regime of operation is thus approaching a more vacuum spark-like regime. Mean ion charge states of up to 6.2 for tungsten and 3.7 for titanium have been measured, with the corresponding maximum charge states of up to 8+ and 6+, respectively. The results are discussed in terms of Saha calculations and freezing of the charge state distribution

  10. Nanostructured current sources based on carbon nanotubes excited by β radiation

    International Nuclear Information System (INIS)

    Saurov, A. N.; Bulyarskiy, S. V.; Risovaniy, V. D.; Pavlov, A. A.; Abanin, I. E.; Kitsyuk, E. P.; Shamanaev, A. A.; Lebedev, E. A.

    2016-01-01

    An analysis of available and promising developments is carried out in the field of power elements based on β decay. The possible fabrication technologies are described, and the efficiency of the power sources manufactured with them is calculated. The possibility of designing a self-charging supercapacitor based on carbon nanotubes is considered with the use of "6"3Ni and "1"4C isotopes, and theoretical calculation confirms the promising nature of this line of research.

  11. Nanostructured current sources based on carbon nanotubes excited by β radiation

    Energy Technology Data Exchange (ETDEWEB)

    Saurov, A. N. [SMC Technological Center (Russian Federation); Bulyarskiy, S. V. [Russian Academy of Sciences, Microelectronics Nanotechnology Institute, INME (Russian Federation); Risovaniy, V. D. [CJSC Science and Innovation (Russian Federation); Pavlov, A. A. [Russian Academy of Sciences, Microelectronics Nanotechnology Institute, INME (Russian Federation); Abanin, I. E.; Kitsyuk, E. P.; Shamanaev, A. A. [SMC Technological Center (Russian Federation); Lebedev, E. A., E-mail: dr.beefheart@gmail.com [National Research University Moscow Institute of Electronic Technology (MIET) (Russian Federation)

    2016-12-15

    An analysis of available and promising developments is carried out in the field of power elements based on β decay. The possible fabrication technologies are described, and the efficiency of the power sources manufactured with them is calculated. The possibility of designing a self-charging supercapacitor based on carbon nanotubes is considered with the use of {sup 63}Ni and {sup 14}C isotopes, and theoretical calculation confirms the promising nature of this line of research.

  12. Experimental studies of 2.45 GHz ECR ion sources for the production of high intensity currents

    International Nuclear Information System (INIS)

    Coly, A.

    2010-12-01

    This thesis is the result of a collaboration between the Pantechnik company and the LPSC (Laboratory of subatomic physics and cosmology of Grenoble). It consisted in the development of a new test bench dedicated to the characterization of a 2.45 GHz ECR ion sources with the aim of the production of high currents beams for industrial purposes. Two ECR ions sources with different magnetic structures have been tested around the same RF injection system. A new 2.45 GHz ECRIS, named SPEED, featuring a dipolar magnetic field at the extraction has been designed and tested. A study of the beam extraction in the dipolar magnetic field is proposed. First tests have shown a total ionic current density of about 10 mA/cm 2 with a 900 W RF power. Tests with hydrogen plasma have shown a maximum of current on the H 2 + species. Recommendations are given to modify the magnetic structure to improve the H + production yield. The MONO1000 ion source has been tested at high RF power with a wave guide type injection system. Intense total ionic current densities have been measured up to about 95 mA/cm 2 with a diode extraction system. First results using an improved 5 electrode extraction system are presented. (author)

  13. Low-Cost Open-Source Voltage and Current Monitor for Gas Metal Arc Weld 3D Printing

    OpenAIRE

    Pinar, A.; Wijnen, B.; Anzalone, G. C.; Havens, T. C.; Sanders, P. G.; Pearce, J. M.

    2015-01-01

    Arduino open-source microcontrollers are well known in sensor applications for scientific equipment and for controlling RepRap 3D printers. Recently low-cost open-source gas metal arc weld (GMAW) RepRap 3D printers have been developed. The entry-level welders used have minimal controls and therefore lack any real-time measurement of welder voltage or current. The preliminary work on process optimization of GMAW 3D printers requires a low-cost sensor and data logger system to measure welder cu...

  14. Current State and Prospects of Studying Sources on the History of Crimean Khanate in Turkish Archives »

    Directory of Open Access Journals (Sweden)

    Sh.E. Seit-Mametov

    2016-09-01

    Full Text Available Research objectives: to consider the current state of the study of sources on the history of the Crimean Khanate in Turkish archives and determine the prospects for the study of this issue. Research materials: works of domestic and foreign Orientalists in the study of the Crimean sources in Turkish archives. Results and novelty of the research: the author analyzed the current state of the study of sources on the history of the Crimean Khanate in Turkish archives. The works of such prominent scholars as A. Bennigsen, Ö. Gokbilgin, A.N. Kurat, Ch. Lemercier-Quelquejay, V.D. Smirnov and others deserve the most attention. Sophisticated paleography (age and conditions of documents of the Ottoman sources and difficulties with their translation were the main reason for their insufficient use. In their studies, Orientalists presents facsimiles of the originals of letters and their translations, give the transcript values of complex or controversial words, solve problems with the translation of dates into the modern chronology and also produce a detailed external criticism of documents: they describe their length, quality of the paper, handwriting and also decode the khans’ seals. This enables modern researchers to get acquainted with some of the earliest sources on the history of the Crimean Khanate. The author has revealed a number of new challenges that need to be addressed in the further study of sources on the history of the Crimean Khanate: translation of foreign Orientalists’ works into Russian as well as synthesis and integration of predecessors’ works, since each individual work does not cover all the documents of interest to modern scholars. The study of sources on the history of the Crimean Khanate remains a promising challenge for modern researchers, since in Turkish archives are stored unpublished documents waiting for their turn to enter into scholarly circulation.

  15. Computation of magnetic fields within source regions of ionospheric and magnetospheric currents

    DEFF Research Database (Denmark)

    Engels, U.; Olsen, Nils

    1998-01-01

    A general method of computing the magnetic effect caused by a predetermined three-dimensional external current density is presented. It takes advantage of the representation of solenoidal vector fields in terms of toroidal and poloidal modes expressed by two independent series of spherical harmon...

  16. Experimental Study of Thermoelectric Generator as Electrical Source of Impressed Current Cathodic Protection for Ship Hull

    Directory of Open Access Journals (Sweden)

    Adi Kurniawan

    2017-06-01

    Full Text Available Impressed Current Cathodic Protection (ICCP is a method to protect metallic material such as ship hull from corrosion by using electric current. In this research, a prototype of thermoelectric generator is developed in order to supply the ICCP system. This thermoelectric generator is planned to utilize the exhaust gas from main engine of the ship. Method carried in this research is assembling the prototype of thermoelectric generator followed by conducted experiment to observe the potential energy of the prototype. After that, the required number of thermoelectric generator is calculated to supply the ICCP system to protect the ship from corrosion. The object in this research is live fish carrier “Wellboat” which has 396.08 m2 wetted area. The required voltage and current to protect the ship from corrosion for three years are 16.67 Volt and 2.66 Ampere. Based on the experiment, a prototype of thermoelectric generator can generate 0.34 Ampere and 4.43 Volt, causing the need of 8 series and 4 parallels connection. It can be concluded that the corrosion rate on the ship hull can be decelerated by using impressed current cathodic protection method without needing additional cost or fuel consumption to produce electric energy.  

  17. Recent references

    International Nuclear Information System (INIS)

    Ramavataram, S.

    1991-01-01

    In support of a continuing program of systematic evaluation of nuclear structure data, the National Nuclear Data Center maintains a complete computer file of references to the nuclear physics literature. Each reference is tagged by a keyword string, which indicates the kinds of data contained in the article. This master file of Nuclear Structure References (NSR) contains complete keyword indexes to literature published since 1969, with partial indexing of older references. Any reader who finds errors in the keyword descriptions is urged to report them to the National Nuclear Data Center so that the master NSR file can be corrected. In 1966, the first collection of Recent References was published as a separate issue of Nuclear Data Sheets. Every four months since 1970, a similar indexed bibliography to new nuclear experiments has been prepared from additions to the NSR file and published. Beginning in 1978, Recent References was cumulated annually, with the third issue completely superseding the two issues previously published during a given year. Due to publication policy changes, cumulation of Recent Reference was discontinued in 1986. The volume and issue number of all the cumulative issues published to date are given. NNDC will continue to respond to individual requests for special bibliographies on nuclear physics topics, in addition to those easily obtained from Recent References. If the required information is available from the keyword string, a reference list can be prepared automatically from the computer files. This service can be provided on request, in exchange for the timely communication of new nuclear physics results (e.g., preprints). A current copy of the NSR file may also be obtained in a standard format on magnetic tape from NNDC. Requests for special searches of the NSR file may also be directed to the National Nuclear Data Center

  18. Radio frequency glow discharge source with integrated voltage and current probes used for evaluation of discharge parameters

    International Nuclear Information System (INIS)

    Wilken, L.; Hoffmann, V.; Wetzig, K.

    2006-01-01

    A radio frequency (rf) Grimm-type glow discharge source for the chemical analysis of solid samples, with integrated voltage and current probes, was developed. All elements of a plasma equivalent circuit are determined from the measured current-voltage characteristics. The procedure is based on the independent evaluation of the ion current and electron current region. The physical meaning of the parameters is investigated by comparisons with measurements from dc glow discharges. We found that the reduced rf current of the powered electrode is comparable to the reduced current in dc discharges. A formula is developed that corrects the reduced current due to gas heating. The sheath thickness at the powered rf electrode is evaluated and is between 75 and 1100 μm. The voltage of the bulk plasma is in the range 2-15 V, and the resistance is between 30 and 400 Ω. The bulk plasma consumes about 3% of the total power, and the reduced voltage is comparable to the reduced electrical field in the positive column of direct current discharges. The sheath voltage at the grounded electrode is in the range 25-100 V, the capacities are between 10 and 400 pF, and the resistances are in the range 100 Ω-5000 Ω. We also found invariants for the evaluated sheath parameters

  19. A Current Control Approach for an Abnormal Grid Supplied Ultra Sparse Z-Source Matrix Converter with a Particle Swarm Optimization Proportional-Integral Induction Motor Drive Controller

    Directory of Open Access Journals (Sweden)

    Seyed Sina Sebtahmadi

    2016-11-01

    Full Text Available A rotational d-q current control scheme based on a Particle Swarm Optimization- Proportional-Integral (PSO-PI controller, is used to drive an induction motor (IM through an Ultra Sparse Z-source Matrix Converter (USZSMC. To minimize the overall size of the system, the lowest feasible values of Z-source elements are calculated by considering the both timing and aspects of the circuit. A meta-heuristic method is integrated to the control system in order to find optimal coefficient values in a single multimodal problem. Henceforth, the effect of all coefficients in minimizing the total harmonic distortion (THD and balancing the stator current are considered simultaneously. Through changing the reference point of magnitude or frequency, the modulation index can be automatically adjusted and respond to changes without heavy computational cost. The focus of this research is on a reliable and lightweight system with low computational resources. The proposed scheme is validated through both simulation and experimental results.

  20. Current approaches on the management of disused sealed sources in Bulgaria

    International Nuclear Information System (INIS)

    Benitez-Navarro, J. C.; Canizares, J.; Asuar, O.; Tapia, J.; Demireva, E.; Yordanova, O.; Stefanova, I.; Karadzhov, S.

    2005-01-01

    The main options for the safe management of existing Disused Sealed Radioactive Sources (DSRS) in Bulgaria are discussed. The specific installations for handling and conditioning of all type of DSRS are being designed. The necessary equipment and materials for all conditioning operations have been defined. As the final disposal route for the radioactive wastes in Bulgaria is not defined yet, the proposed conditioning process for the DSRS ensures that end-point disposal of DSRS is not jeopardized by actions taken at present. All the DSRS would be packaged in secure, safe, monitorable and retrievable manner for interim storage

  1. Analysis and design of grid-current-feedback active damping for LCL resonance in grid-connected voltage source converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2014-01-01

    This paper investigates the active damping of LCL-filter resonance within single-loop grid current control of grid-connected voltage source converters. First, the basic analysis in the continuous s-domain reveals that the grid-current-feedback active damping forms a virtual impedance across...... in a digital control system. The instability induced by the negative virtual resistance, which is commonly experienced in the feedback-type active damping, can thus be avoided. A systematic design method of the highpass filter is also proposed by the help of root locus analysis in the discrete z-domain. Lastly...

  2. Grid-Current-Feedback Active Damping for LCL Resonance in Grid-Connected Voltage-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2016-01-01

    This paper investigates active damping of LCL-filter resonance in a grid-connected voltage-source converter with only grid-current feedback control. Basic analysis in the s-domain shows that the proposed damping technique with a negative high-pass filter along its damping path is equivalent...... of phase-lag, in turn, helps to shrink the region of nonminimum-phase behavior caused by negative virtual resistance inserted unintentionally by most digitally implemented active damping techniques. The presented high-pass-filtered active damping technique with a single grid-current feedback loop is thus...

  3. Design of a New Acceleration System for High-Current Pulsed Proton Beams from an ECR Source

    Science.gov (United States)

    Cooper, Andrew L.; Pogrebnyak, Ivan; Surbrook, Jason T.; Kelly, Keegan J.; Carlin, Bret P.; Champagne, Arthur E.; Clegg, Thomas B.

    2014-03-01

    A primary objective for accelerators at TUNL's Laboratory for Experimental Nuclear Astrophysics (LENA) is to maximize target beam intensity to ensure a high rate of nuclear events during each experiment. Average proton target currents of several mA are needed from LENA's electron cyclotron resonance (ECR) ion source because nuclear cross sections decrease substantially at energies of interest tube structures; and provide better heat dissipation by using deionized water to provide the current drain needed to establish the accelerating tube's voltage gradient. Details of beam optical modeling calculations, proposed accelerating tube design, and initial beam pulsing tests will be described. Work supported in part by USDOE Office of HE and Nuclear Physics.

  4. Current-voltage characteristics of a gas field ion source with a supertip

    International Nuclear Information System (INIS)

    Boerret, R.; Boehringer, K.; Kalbitzer, S.

    1990-01-01

    The field ionisation properties of a supertip, a fine protrusion on top of a regular emitter, have been studied for hydrogen and the lighter rare gases. The parameter set included tip temperature, tip radius, gas temperature and gas pressure. Due to the local field enhancement at the supertip site, angular current intensities of 35 μA sr -1 and values of brightness up to 10 10 A cm -2 sr -1 have been obtained near the optimum temperature of the gas-tip system. At temperatures below this, the gas density reaches values typical for a condensed phase. In geometrical proportion, the regular tip area appears to serve as a gas supply for the supertip current. (author)

  5. Current status of agricultural and rural non-point source Pollution assessment in China

    International Nuclear Information System (INIS)

    Ongley, Edwin D.; Zhang Xiaolan; Yu Tao

    2010-01-01

    Estimates of non-point source (NPS) contribution to total water pollution in China range up to 81% for nitrogen and to 93% for phosphorus. We believe these values are too high, reflecting (a) misuse of estimation techniques that were developed in America under very different conditions and (b) lack of specificity on what is included as NPS. We compare primary methods used for NPS estimation in China with their use in America. Two observations are especially notable: empirical research is limited and does not provide an adequate basis for calibrating models nor for deriving export coefficients; the Chinese agricultural situation is so different than that of the United States that empirical data produced in America, as a basis for applying estimation techniques to rural NPS in China, often do not apply. We propose a set of national research and policy initiatives for future NPS research in China. - Estimation techniques used in China for non-point source pollution are evaluated as a basis for recommending future policies and research in NPS studies in China.

  6. Size of the virtual source behind a convex spherical surface emitting a space charge limited ion current

    International Nuclear Information System (INIS)

    Chavet, I.

    1987-01-01

    A plasma source fitted with a circular orifice and emitting a space charge limited ion current can be made to operate with a convex spherical plasma boundary (meniscus) by appropriately adjusting its extraction parameters. In this case, the diameter of the virtual source behind the meniscus is much smaller than the orifice diameter. The effective value of this virtual source diameter depends significantly on various practical factors that are more or less controllable. Its lower ideal limit, however, depends only on the radio δ of the interelectrode distance to the meniscus curvature radius and on the ratio ω of the initial to final ion energy. This ideal limit is given for the ranges 0.1 ≤ δ ≤ 10 and 10 -7 ≤ ω ≤ 10 -3 . Preliminary experimental results are reported. (orig.)

  7. Obtaining source current density related to irregularly structured electromagnetic target field inside human body using hybrid inverse/FDTD method.

    Science.gov (United States)

    Han, Jijun; Yang, Deqiang; Sun, Houjun; Xin, Sherman Xuegang

    2017-01-01

    Inverse method is inherently suitable for calculating the distribution of source current density related with an irregularly structured electromagnetic target field. However, the present form of inverse method cannot calculate complex field-tissue interactions. A novel hybrid inverse/finite-difference time domain (FDTD) method that can calculate the complex field-tissue interactions for the inverse design of source current density related with an irregularly structured electromagnetic target field is proposed. A Huygens' equivalent surface is established as a bridge to combine the inverse and FDTD method. Distribution of the radiofrequency (RF) magnetic field on the Huygens' equivalent surface is obtained using the FDTD method by considering the complex field-tissue interactions within the human body model. The obtained magnetic field distributed on the Huygens' equivalent surface is regarded as the next target. The current density on the designated source surface is derived using the inverse method. The homogeneity of target magnetic field and specific energy absorption rate are calculated to verify the proposed method.

  8. Experimental study of high current negative ion sources D- / H-. Analysis based on the simulation of the negative ion transport in the plasma source

    International Nuclear Information System (INIS)

    Riz, D.

    1996-01-01

    In the frame of the development of a neutral beam injection system able to work the ITER tokamak (International Thermonuclear Experimental Reactor), two negative ion sources, Dragon and Kamaboko, have been installed on the MANTIS test bed in Cadarache, and studies in order to extract 20 mA/cm 2 of D - . The two production modes of negative ions have been investigated: volume production; surface production after cesium injection in the discharge. Experiments have shown that cesium seeding is necessary in order to reach the requested performances for ITER. 20 mA/cm 2 have been extracted from the Kamaboko source for an arc power density of 2.5 kW/liter. Simultaneously, a code called NIETZSCHE has been developed to simulate the negative ions transport in the source plasma, from their birth place to the extraction holes. The ion trajectory is calculated by numerically solving the 3D motion equation, while the atomic processes of destruction, of elastic collisions H - /H + and of charge exchange H - /H 0 are handled at each time step by a Monte Carlo procedure. The code allows to obtain the extraction probability of a negative ion produced at a given location. The calculations performed with NIETZSCHE have allowed to explain several phenomena observed on negative ion sources, such as the isotopic effect H - /D - and the influence of the polarisation of the plasma grid and of the magnetic filter on the negative ions current. The code has also shown that, in the type of sources contemplated for ITER, working with large arc power densities (> 1 kW/liter), only negative ions produced in volume at a distance lower that 2 cm from the plasma grid and those produced at the grid surface have a chance of being extracted. (author)

  9. Current regulatory and licensing status for byproduct sources, facilities and applications

    International Nuclear Information System (INIS)

    Tingey, G.L.; Jensen, G.A.; Hazelton, R.F.

    1985-02-01

    Public use of nuclear byproducts, especially radioactive isotopes, will require approval by various regulatory agencies. Use of cesium-137 as an irradiation source for sterilizing medical products will require US Nuclear Regulatory Commission (NRC) approval. Two applications have been filed with NRC, and approval is expected soon. Widespread use of irradiation for food products depends on a favorable ruling by the Food and Drug Administration (FDA). A ruling is pending that would permit irradiation of fruits and vegetables up to 100 krad. NRC also controls the use of isotopes in remote power generators, but little regulatory action has been required in recent years. Recent development of radioluminescent (RL) lighting for runway lights has led to interest by commercial manufacturers. At the present time, a license has been issued to at least one manufacturer for sale of tritium-powered runway lights. 28 refs., 1 fig

  10. IFMIF, a fusion relevant neutron source for material irradiation current status

    International Nuclear Information System (INIS)

    Knaster, J.; Chel, S.; Fischer, U.; Groeschel, F.; Heidinger, R.; Ibarra, A.; Micciche, G.; Möslang, A.; Sugimoto, M.; Wakai, E.

    2014-01-01

    The d-Li based International Fusion Materials Irradiation Facility (IFMIF) will provide a high neutron intensity neutron source with a suitable neutron spectrum to fulfil the requirements for testing and qualifying fusion materials under fusion reactor relevant irradiation conditions. The IFMIF project, presently in its Engineering Validation and Engineering Design Activities (EVEDA) phase under the Broader Approach (BA) Agreement between Japan Government and EURATOM, aims at the construction and testing of the most challenging facility sub-systems, such as the first accelerator stage, the Li target and loop, and irradiation test modules, as well as the design of the entire facility, thus to be ready for the IFMIF construction with a clear understanding of schedule and cost at the termination of the BA mid-2017. The paper reviews the IFMIF facility and its principles, and reports on the status of the EVEDA activities and achievements

  11. Solid waste as renewable source of energy. Current and future possibility in Algeria

    Energy Technology Data Exchange (ETDEWEB)

    Taqiy Eddine, Boukelia; Salah, Mecibah Med [Mentouri Univ., Constantine (Algeria). Mechanical Dept.

    2012-11-01

    Algeria has created a green momentum by launching an ambitious program to develop renewable energies and promote energy efficiency. Solid waste is one of most important sources of biomass potential in Algeria, which can be used as renewable energy sources. With economic development and the evolution of population, the quantity of solid waste is increasing rapidly in Algeria; according to the National Cadastre for Solid Waste Generation, the overall generation of municipal solid waste was more than 10.3 million tons per year, and the amount of industrial solid waste, including non-hazardous and inert industrial waste was 2,547,000 tons per year, with a stock quantity of 4,483,500 tons. The hazardous waste generated amounts to 325,100 tons per year; the quantities of waste in stock and awaiting a disposal solution amount to 2,008,500 tons. Healthcare waste reaches to 125,000 tons per year. The management of solid waste and its valorization is based on the understanding of solid waste composition by its categories and physicochemical characteristics. Elimination is the solution applied to 97% of waste produced in Algeria. Wastes are disposed in the following ways: open dumps (57%), burned in the open air in public dumps or municipal uncontrolled ones (30%), and controlled dumps and landfill (10%). On the other side, the quantities destined for recovery are too low: only 2% for recycling and 1% for composting. Waste to energy is very attractive option for elimination solid waste with energy recovery. In this paper, we give an overview for this technology, including its conversion options and its useful products (such as electricity, heat and transportation fuel), and waste to energy-related environmental issues and its challenges. (orig.)

  12. Simple laser-driven, metal photocathodes as cold, high-current electron sources

    International Nuclear Information System (INIS)

    Saunders, J.D.; Ringler, T.J.; Builta, L.A.; Kauppila, T.J.; Moir, D.C.; Downey, S.W.

    1987-01-01

    Recent developments in excimer laser design have made near ultraviolet light intensities of several MWcm 2 possible in unfocused beams. These advances and recent experiments indicate that high-current, simple-metal photoemissive electron guns are now feasible. Producing more than 50 Acm 2 of illuminated cathode surface, the guns could operate at vacuums of 10 -6 torr with no complicated system components inside the vacuum enclosure. The electron beam produced by such photoemission guns would have very low emittance and high brightness. This beam would also closely follow the temporal characteristics of the laser pulse, making fast risetime, ultrashort electron beam pulses possible

  13. Constant-current charging supplies for the Advanced Photon Source (APS) linear accelerator modulators

    International Nuclear Information System (INIS)

    Fuja, R.; Grelick, A.E.; Meyer, D.

    1997-01-01

    The APS linac beam energy must be stable to within ±1% to match the energy acceptance of the positron accumulator ring. The klystron pulse modulators must therefore provide a pulse-to-pulse repeatability of 0.1% in order for the beam to have the required energy stability. The modulators have had difficulty achieving the necessary repeatability since the pulse forming network (PFN) charging scheme does not include a deQing circuit. Several of the major charging circuit components are also less reliable than desired. In order to increase operating reliability and to improve pulse-to-pulse stability, it is planned to replace the high voltage power supplies in all modulators with constant-current power supplies. A new modulator charging supply that contains two EMI series 303 constant-current power supplies was constructed. Each of these EMI supplies delivers 1.5 A at up to 40 kV. One supply is sufficient for linac operation at up to 45 Hz, and two supplies in parallel enable linac operation at the nominal rf repetition rate of 60 Hz. This paper discusses test results from the new modulator, and also describes the existing modulators and their performance limitations

  14. Relationship between Hard X-Ray Footpoint Sources and Photospheric Electric Currents in Solar Flares: a Statistical Study

    Science.gov (United States)

    Zimovets, I. V.; Sharykin, I. N.; Wang, R.; Liu, Y. D.; Kosovichev, A. G.

    2017-12-01

    It is believed that solar flares are a result of release of free magnetic energy contained in electric currents (ECs) flowing in active regions (ARs). However, there are still debates whether the primary energy release and acceleration of electrons take place in coronal current sheets or in chromospheric footpoints of current-carrying magnetic flux tubes (loops). We present results of an observational statistical study of spatial relationship between hard X-ray (HXR; EHXR≥50keV) footpoint sources detected by RHESSI and vertical photospheric ECs calculated using vector magnetograms obtained from the SDO/HMI data. We found that for a sample of 47 flares (from C3.0 to X3.1 class) observed on the solar disk by both instruments in 2010-2016, at least one HXR source was in a region of strong (within 20% of the maximum EC density in the corresponding ARs) vertical ECs having the form of a ribbon (79%) or an island (21%). The total vertical ECs in such HXR sources are in the range of 1010-1013 A. The EC density is in the range of 0.01-1.0 A/m2. We found no correlation between intensity of the HXR sources and the EC density. By comparing pre-flare and post-flare EC maps we did not find evidences of significant dissipation of vertical ECs in the regions corresponding to the HXR sources. In some cases, we found amplification of ECs during flares. We discuss effects of sensitivity and angular resolution of RHESSI and SDO/HMI. In general, the results indicate that there is a link between the flare HXR footpoint sources and enhanced vertical ECs in the photosphere. However, the results do not support a concept of electron acceleration by the electric field excited in footpoints of current-carrying loops due to some (e.g. Rayleigh-Taylor) instabilities (Zaitsev et al., 2016), since strong correlation between the HXR intensity and the EC density is expected in such concept.

  15. Review of current GPS methodologies for producing accurate time series and their error sources

    Science.gov (United States)

    He, Xiaoxing; Montillet, Jean-Philippe; Fernandes, Rui; Bos, Machiel; Yu, Kegen; Hua, Xianghong; Jiang, Weiping

    2017-05-01

    The Global Positioning System (GPS) is an important tool to observe and model geodynamic processes such as plate tectonics and post-glacial rebound. In the last three decades, GPS has seen tremendous advances in the precision of the measurements, which allow researchers to study geophysical signals through a careful analysis of daily time series of GPS receiver coordinates. However, the GPS observations contain errors and the time series can be described as the sum of a real signal and noise. The signal itself can again be divided into station displacements due to geophysical causes and to disturbing factors. Examples of the latter are errors in the realization and stability of the reference frame and corrections due to ionospheric and tropospheric delays and GPS satellite orbit errors. There is an increasing demand on detecting millimeter to sub-millimeter level ground displacement signals in order to further understand regional scale geodetic phenomena hence requiring further improvements in the sensitivity of the GPS solutions. This paper provides a review spanning over 25 years of advances in processing strategies, error mitigation methods and noise modeling for the processing and analysis of GPS daily position time series. The processing of the observations is described step-by-step and mainly with three different strategies in order to explain the weaknesses and strengths of the existing methodologies. In particular, we focus on the choice of the stochastic model in the GPS time series, which directly affects the estimation of the functional model including, for example, tectonic rates, seasonal signals and co-seismic offsets. Moreover, the geodetic community continues to develop computational methods to fully automatize all phases from analysis of GPS time series. This idea is greatly motivated by the large number of GPS receivers installed around the world for diverse applications ranging from surveying small deformations of civil engineering structures (e

  16. Fault Ride-through Capability Enhancement of Voltage Source Converter-High Voltage Direct Current Systems with Bridge Type Fault Current Limiters

    Directory of Open Access Journals (Sweden)

    Md Shafiul Alam

    2017-11-01

    Full Text Available This paper proposes the use of bridge type fault current limiters (BFCLs as a potential solution to reduce the impact of fault disturbance on voltage source converter-based high voltage DC (VSC-HVDC systems. Since VSC-HVDC systems are vulnerable to faults, it is essential to enhance the fault ride-through (FRT capability with auxiliary control devices like BFCLs. BFCL controllers have been developed to limit the fault current during the inception of system disturbances. Real and reactive power controllers for the VSC-HVDC have been developed based on current control mode. DC link voltage control has been achieved by a feedback mechanism such that net power exchange with DC link capacitor is zero. A grid-connected VSC-HVDC system and a wind farm integrated VSC-HVDC system along with the proposed BFCL and associated controllers have been implemented in a real time digital simulator (RTDS. Symmetrical three phase as well as different types of unsymmetrical faults have been applied in the systems in order to show the effectiveness of the proposed BFCL solution. DC link voltage fluctuation, machine speed and active power oscillation have been greatly suppressed with the proposed BFCL. Another significant feature of this work is that the performance of the proposed BFCL in VSC-HVDC systems is compared to that of series dynamic braking resistor (SDBR. Comparative results show that the proposed BFCL is superior over SDBR in limiting fault current as well as improving system fault ride through (FRT capability.

  17. Design of current controller of grid-connected voltage source converter based internal model control in wind power

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xianping; Guo Jindong; Xu Honghua [Inst. of Electrical Engineering, Chinese Academy of Sciences, BJ (China)

    2008-07-01

    Grid-connected voltage source converter (VSC) is important for variable speed turbines with doubly fed induction generator (DFIG), and bad performance of current loop of VSC may cause VSC inject much low and high order harmonics into grid. Therefore, design of current controller of VSC is very important. PI regulator is often used to regulate current error in dq rotating coordinate to obtain zero steady error. However, it is complex to design PI parameters, and researchers need many trial-and-error steps. Therefore, a novel and simple design method of PI regulator for grid-connected VSC, which is based internal model control (IMC), has been presented in this paper. The parameters of PI regulator can be expressed directly with certain L-type line filter parameters and the desired closed-loop bandwidth. At last, The simulation has been done and result shows that the method in this paper is easy and useful to regulate PI parameters. (orig.)

  18. Development of high current electron source using photoemission from metals with ultrashort laser pulses

    International Nuclear Information System (INIS)

    Tsang, T.; Srinivasan-Rao, T.; Fischer, J.

    1990-10-01

    We summarize the studies of photoemission from metal photocathodes using picosecond pulses in the UV (4.66 eV) wavelength and femtosecond laser pulses in the visible (2 eV) wavelengths. To achieve high current density yield from metal photocathodes, multiphoton photoemission using femtosecond laser pulses are suggested. Electron yield improvement incorporating surface photoemission and surface plasmon resonance in metals and metal films are demonstrated. We examine the possibility of the nonlinear photoemission process overtaking the linear process, and identity some possible complexity. To extract the large amount of electrons free of space charge, a pulsed high voltage is designed; the results of the preliminary test are presented. Finally, for the first time, the width of the electron temporal profiles are measured, utilizing the nonlinear photoelectric effect, to below 100 fsec time regime. The results indicated that the electron pulse duration follows the laser pulses and are not limited by the material. 8 refs., 15 figs

  19. Measuring biomarkers in wastewater as a new source of epidemiological information: Current state and future perspectives

    DEFF Research Database (Denmark)

    Gracia-Lor, Emma; Castiglioni, Sara; Bade, Richard

    2017-01-01

    The information obtained from the chemical analysis of specific human excretion products (biomarkers) in urban wastewater can be used to estimate the exposure or consumption of the population under investigation to a defined substance. A proper biomarker can provide relevant information about...... lifestyle habits, health and wellbeing, but its selection is not an easy task as it should fulfil several specific requirements in order to be successfully employed. This paper aims to summarize the current knowledge related to the most relevant biomarkers used so far. In addition, some potential wastewater...... in the environment and food, (iii) those that have the potential to provide information about public health and illness and (iv) those used to estimate the population size. To facilitate the evaluation of the eligibility of a compound as a biomarker, information, when available, on stability in urine and wastewater...

  20. Electricity sector in Mexico. Current status. Contribution of renewable energy sources

    International Nuclear Information System (INIS)

    Cancino-Solorzano, Yoreley; Villicana-Ortiz, Eunice; Gutierrez-Trashorras, Antonio J.; Xiberta-Bernat, Jorge

    2010-01-01

    The challenge facing the world electricity sector is the cost incurred in maintaining the system and seeing to the environmental effects it causes. In Mexico the grid is supplied by thermal plants fed by oil products. Its great potential of renewable energies clearly shown in studies by national and international scholars has led the government to become more committed to take advantage of these energies. The goal is to reduce dependence on fossil fuels to generate electricity and to reduce the emission of greenhouse gases. In this article we analyse the current state of renewable energies, the conditions needed to foster them and the legislative changes already introduced to promote their greater part in the national electricity grid. (author)

  1. Electricity sector in Mexico. Current status. Contribution of renewable energy sources

    Energy Technology Data Exchange (ETDEWEB)

    Cancino-Solorzano, Yoreley [Departamento de Ing. Electrica-Electronica, Instituto Tecnologico de Veracruz, Calzada Miguel A. de Quevedo 2779, 91860 Veracruz (Mexico); Villicana-Ortiz, Eunice; Gutierrez-Trashorras, Antonio J.; Xiberta-Bernat, Jorge [Departamento de Energia, Escuela Tecnica Superior de Ingenieros de Minas, Universidad de Oviedo, C/Independencia, 13, 2a Planta, 33004 Oviedo (Spain)

    2010-01-15

    The challenge facing the world electricity sector is the cost incurred in maintaining the system and seeing to the environmental effects it causes. In Mexico the grid is supplied by thermal plants fed by oil products. Its great potential of renewable energies clearly shown in studies by national and international scholars has led the government to become more committed to take advantage of these energies. The goal is to reduce dependence on fossil fuels to generate electricity and to reduce the emission of greenhouse gases. In this article we analyse the current state of renewable energies, the conditions needed to foster them and the legislative changes already introduced to promote their greater part in the national electricity grid. (author)

  2. Second Order Generalized Integrator Based Reference Current Generation Method for Single-Phase Shunt Active Power Filters Under Adverse Grid Conditions

    DEFF Research Database (Denmark)

    Golestan, Saeed; Monfared, Mohammad; Guerrero, Josep M.

    2013-01-01

    The reference current generation (RCG) is a crucial part in the control of a shunt active power filter (APF). A variety of RCG techniques have been proposed in literature. Among these, the instantaneous reactive power theory, called pq theory, is probably the most widely used technique. The pq...... theory offers advantages such as satisfactory steady-state and dynamic performance, and at the same time simple digital implementation, however its application was limited to three-phase systems. To exploit the advantages of pq theory in single-phase systems, the single-phase pq theory has been proposed...... recently. In this paper, a simple and effective implementation of the single phase pq theory for single-phase shunt APFs is proposed. The suggested approach is based on employing second order generalized integrators (SOGI), and a phase locked loop (PLL). To fine tune the control parameters, a systematic...

  3. The current status of small-angle x-ray scattering beamline at Diamond Light Source

    International Nuclear Information System (INIS)

    Inoue, Katsuaki; Doutch, James; Terrill, Nick

    2013-01-01

    The small-angle X-ray scattering (SAXS) covers the major disciplines of biology, chemistry and physics delivering structural and dynamic information in nanoscience, mesoscopic architectures, supramolecular structures, and nucleation/growth of crystals. SAXS is also proving to be important in archaeological, environmental, and conservation sciences, and has further indicated its ability to span wide-ranging scientific disciplines. Thus, strong needs for SAXS studies are increasing significantly in a broad range of scientific fields year by year. Based on such a background, the demand for high throughput SAXS experiments is increasing. At the synchrotron facility, Diamond Light Source, one SAXS beamline, Non-crystalline diffraction I22 is now operational and highly automated throughput small-angle X-ray scattering (HATSAXS) beamline B21 is now under construction. I22 is the Undulator beamline and wide varieties of experiments, including time-resolved experiments are attempted. Based on the concept of HATSAXS, the key feature of B21 will focuses on the automation of end-station equipment. A automated sample changer has been purchased for solution SAXS measurements on biomolecules. A robotic-arm-type automated sample changer that is capable of handling several kinds of samples in material science is also being constructed. B21 is expected to successfully provide all users highly automated throughput measurements with the highest possible reliability and accuracy. Construction of this beamline will end in the second half of 2012, and will be open for users in the early summer of 2013 after commissioning. (author)

  4. CURRENT TEACHING SITUATION AND POSSIBILITIES OF OMBROTHERMIC DIAGRAM AS DIGITAL SOURCE

    Directory of Open Access Journals (Sweden)

    Daniel David Martínez Romera

    Full Text Available INTRODUCCIÓN: The main purpose of the present paper is to check how fits Geography technical basis with technological offer available on the Net, having in mind freeware or open source apps only; And, if needed, to design and to build a free digital resource in order to bridge that gap.For us, the starting point is the tradeoff between time spent and scientific accuracy in the classroom. Regardless of the academic level deemed, every teacher is facing this sensitive issue: the longer technical or epistemological questions requires the less contents can be taught. So, in fact, curricular thoroughness tips the balance towards itself, weakening the technical and epistemological aspects. In such context, the specific didactics, such as in the case of Geography, seek new forms of teaching and learning in the ICT world that allows to achive at least: an active role of the students, according to Ausubel, an analytic defiance, in the terms of Vygotsky, and a efficient man-machine interaction, retaking Licklider’s ideas.

  5. The IPEM code of practice for determination of the reference air kerma rate for HDR 192Ir brachytherapy sources based on the NPL air kerma standard

    International Nuclear Information System (INIS)

    Bidmead, A M; Sander, T; Nutbrown, R F; Locks, S M; Lee, C D; Aird, E G A; Flynn, A

    2010-01-01

    This paper contains the recommendations of the high dose rate (HDR) brachytherapy working party of the UK Institute of Physics and Engineering in Medicine (IPEM). The recommendations consist of a Code of Practice (COP) for the UK for measuring the reference air kerma rate (RAKR) of HDR 192 Ir brachytherapy sources. In 2004, the National Physical Laboratory (NPL) commissioned a primary standard for the realization of RAKR of HDR 192 Ir brachytherapy sources. This has meant that it is now possible to calibrate ionization chambers directly traceable to an air kerma standard using an 192 Ir source (Sander and Nutbrown 2006 NPL Report DQL-RD 004 (Teddington: NPL) http://publications.npl.co.uk). In order to use the source specification in terms of either RAKR, .K R (ICRU 1985 ICRU Report No 38 (Washington, DC: ICRU); ICRU 1997 ICRU Report No 58 (Bethesda, MD: ICRU)), or air kerma strength, S K (Nath et al 1995 Med. Phys. 22 209-34), it has been necessary to develop algorithms that can calculate the dose at any point around brachytherapy sources within the patient tissues. The AAPM TG-43 protocol (Nath et al 1995 Med. Phys. 22 209-34) and the 2004 update TG-43U1 (Rivard et al 2004 Med. Phys. 31 633-74) have been developed more fully than any other protocol and are widely used in commercial treatment planning systems. Since the TG-43 formalism uses the quantity air kerma strength, whereas this COP uses RAKR, a unit conversion from RAKR to air kerma strength was included in the appendix to this COP. It is recommended that the measured RAKR determined with a calibrated well chamber traceable to the NPL 192 Ir primary standard is used in the treatment planning system. The measurement uncertainty in the source calibration based on the system described in this COP has been reduced considerably compared to other methods based on interpolation techniques.

  6. Current status of ground source heat pumps and underground thermal energy storage in Europe

    Energy Technology Data Exchange (ETDEWEB)

    Sanner, B. [Justus Liebig University, Giessen (Germany). Institute of Applied Geosciences; Karytsas, C.; Mendrinos, D. [Center for Renewable Energy Sources, Pikermi (Greece); Rybach, L. [Geowatt AG, Zurich (Switzerland)

    2003-12-01

    Geothermal Heat Pumps, or Ground Coupled Heat Pumps (GCHP), are systems combining a heat pump with a ground heat exchanger (closed loop systems), or fed by ground water from a well (open loop systems). They use the earth as a heat source when operating in heating mode, with a fluid (usually water or a water-antifreeze mixture) as the medium that transfers the heat from the earth to the evaporator of the heat pump, thus utilising geothermal energy. In cooling mode, they use the earth as a heat sink. With Borehole Heat Exchangers (BHE), geothermal heat pumps can offer both heating and cooling at virtually any location, with great flexibility to meet any demands. More than 20 years of R and D focusing on BUE in Europe has resulted in a well-established concept of sustainability for this technology, as well as sound design and installation criteria. Recent developments are the Thermal Response Test, which allows in-situ-determination of ground thermal properties for design purposes, and thermally enhanced grouting materials to reduce borehole thermal resistance. For cooling purposes, but also for the storage of solar or waste heat, the concept of underground thermal energy storage (UTES) could prove successful. Systems can be either open (aquifer storage) or can use BHE (borehole storage). Whereas cold storage is already established on the market, heat storage, and, in particular, high temperature heat storage (> 50{sup o}C) is still in the demonstration phase. Despite the fact that geothermal heat pumps have been in use for over 50 years now (the first were in the USA), market penetration of this technology is still in its infancy, with fossil fuels dominating the space heating market and air-to-air heat pumps that of space cooling. In Germany, Switzerland, Austria, Sweden, Denmark, Norway, France and the USA, large numbers of geothermal heat pumps are already operational, and installation guidelines, quality control and contractor certification are now major issues

  7. Current and future funding sources for specialty mental health and substance abuse treatment providers.

    Science.gov (United States)

    Levit, Katharine R; Stranges, Elizabeth; Coffey, Rosanna M; Kassed, Cheryl; Mark, Tami L; Buck, Jeffrey A; Vandivort-Warren, Rita

    2013-06-01

    Goals were to describe funding for specialty behavioral health providers in 1986 and 2005 and examine how the recession, parity law, and Affordable Care Act (ACA) may affect future funding. Numerous public data sets and actuarial methods were used to estimate spending for services from specialty behavioral health providers (general hospital specialty units; specialty hospitals; psychiatrists; other behavioral health professionals; and specialty mental health and substance abuse treatment centers). Between 1986 and 2005, hospitals-which had received the largest share of behavioral health spending-declined in importance, and spending shares trended away from specialty hospitals that were largely funded by state and local governments. Hospitals' share of funding from private insurance decreased from 25% in 1986 to 12% in 2005, and the Medicaid share increased from 11% to 23%. Office-based specialty providers continued to be largely dependent on private insurance and out-of-pocket payments, with psychiatrists receiving increased Medicaid funding. Specialty centers received increased funding shares from Medicaid (from 11% to 29%), and shares from other state and local government sources fell (from 64% to 46%). With ACA's full implementation, spending on behavioral health will likely increase under private insurance and Medicaid. Parity in private plans will also push a larger share of payments for office-based professionals from out-of-pocket payments to private insurance. As ACA provides insurance for formerly uninsured individuals, funding by state behavioral health authorities of center-based treatment will likely refocus on recovery and support services. Federal Medicaid rules will increase in importance as more people needing behavioral health treatment become covered.

  8. sources

    Directory of Open Access Journals (Sweden)

    Shu-Yin Chiang

    2002-01-01

    Full Text Available In this paper, we study the simplified models of the ATM (Asynchronous Transfer Mode multiplexer network with Bernoulli random traffic sources. Based on the model, the performance measures are analyzed by the different output service schemes.

  9. The development of a realistic source term for sodium-cooled fast reactors : assessment of current status and future needs.

    Energy Technology Data Exchange (ETDEWEB)

    LaChance, Jeffrey L.; Phillips, Jesse; Parma, Edward J., Jr.; Olivier, Tara Jean; Middleton, Bobby D.

    2011-06-01

    Sodium-cooled fast reactors (SFRs) continue to be proposed and designed throughout the United States and the world. Although the number of SFRs actually operating has declined substantially since the 1980s, a significant interest in advancing these types of reactor systems remains. Of the many issues associated with the development and deployment of SFRs, one of high regulatory importance is the source term to be used in the siting of the reactor. A substantial amount of modeling and experimental work has been performed over the past four decades on accident analysis, sodium coolant behavior, and radionuclide release for SFRs. The objective of this report is to aid in determining the gaps and issues related to the development of a realistic, mechanistically derived source term for SFRs. This report will allow the reader to become familiar with the severe accident source term concept and gain a broad understanding of the current status of the models and experimental work. Further, this report will allow insight into future work, in terms of both model development and experimental validation, which is necessary in order to develop a realistic source term for SFRs.

  10. Method and system for a gas tube switch-based voltage source high voltage direct current transmission system

    Science.gov (United States)

    She, Xu; Chokhawala, Rahul Shantilal; Zhou, Rui; Zhang, Di; Sommerer, Timothy John; Bray, James William

    2016-12-13

    A voltage source converter based high-voltage direct-current (HVDC) transmission system includes a voltage source converter (VSC)-based power converter channel. The VSC-based power converter channel includes an AC-DC converter and a DC-AC inverter electrically coupled to the AC-DC converter. The AC-DC converter and a DC-AC inverter include at least one gas tube switching device coupled in electrical anti-parallel with a respective gas tube diode. The VSC-based power converter channel includes a commutating circuit communicatively coupled to one or more of the at least one gas tube switching devices. The commutating circuit is configured to "switch on" a respective one of the one or more gas tube switching devices during a first portion of an operational cycle and "switch off" the respective one of the one or more gas tube switching devices during a second portion of the operational cycle.

  11. Development of a high-current ion source with slit beam extraction for neutral beam injector of VEST

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Bong-ki; Chung, Kyoung-Jae, E-mail: jkjlsh1@snu.ac.kr; An, Young-Hwa; Park, Jong-Yoon; Hwang, Y.S.

    2015-10-15

    Highlights: • A high-current ion source is developed for NBI system of VEST. • A cold-cathode electron gun is employed to produce primary electrons. • A hemi-cylindrical discharge chamber with cusp magnetic field is used. • Plasma density is measured to be 2 × 10{sup 18} m{sup −3} near the extraction aperture. • NBI power of 90 kW with beam energy of 20 keV is expected to be achieved. - Abstract: A high-current pulsed ion source has been developed for the neutral beam injector of the VEST (Versatile Experiment Spherical Torus) to accommodate high-beta fusion plasma experiments. The ion source consists of two parts: an electron gun for supplying sufficient primary electrons by cold-cathode arc discharge and a hemi-cylindrical discharge chamber where uniform, high-density plasma generated by the primary electrons is confined by multi-cusp magnetic field. A pulse forming network is also developed to drive high current of ∼1 kA to sustain the cold-cathode discharge in the electron gun up to 10 ms. Diagnostics with a triple probe in the discharge chamber shows that a hydrogen plasma whose density is as high as 1 × 10{sup 18} m{sup −3} can be obtained near extraction slits at the gas pressure lower than 0.5 Pa. This value is estimated to be sufficient to deposit a heating power of 90 kW to the VEST plasma when the appropriate extraction through slits with 20 cm{sup 2} in area and acceleration of ion beams up to 20 kV are fulfilled.

  12. Low-level radioactive waste from commercial nuclear reactors. Volume 3. Bibliographic abstracts of significant source references. Part 2. Bibliography for treatment, storage, disposal and transportation regulatory constraints

    Energy Technology Data Exchange (ETDEWEB)

    Jolley, R.L.; Rodgers, B.R.

    1986-05-01

    The overall task of this program was to provide an assessment of currently available technology for treating commercial low-level radioactive waste (LLRW), to initiate development of a methodology for choosing one technology for a given application, and to identify research needed to improve current treatment techniques and decision methodology. The resulting report is issued in four volumes. Volume 3 of this series is a collection of abstracts of most of the reference documents used for this study. Because of the large volume of literature, the abstracts have been printed in two separate parts. Federal, state, and local regulations affect the decision process for selecting technology applications. Regulations may favor a particular technology and may prevent application of others. Volume 3, part 2 presents abstracts of the regulatory constraint documents that relate to all phases of LLRW management (e.g., treatment, packaging, storage, transportation, and disposal).

  13. New strategy for eliminating zero-sequence circulating current between parallel operating three-level NPC voltage source inverters

    DEFF Research Database (Denmark)

    Li, Kai; Dong, Zhenhua; Wang, Xiaodong

    2018-01-01

    A novel strategy based on a zero common mode voltage pulse-width modulation (ZCMV-PWM) technique and zero-sequence circulating current (ZSCC) feedback control is proposed in this study to eliminate ZSCCs between three-level neutral point clamped (NPC) voltage source inverters, with common AC and DC......, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can...

  14. Operation and Modulation of H7 Current Source Inverter with Hybrid SiC and Si Semiconductor Switches

    DEFF Research Database (Denmark)

    Wang, Weiqi; Gao, Feng; Yang, Yongheng

    2018-01-01

    This paper proposes an H7 current source inverter (CSI) consisting of a single parallel-connected silicon carbide (SiC) switch and a traditional silicon (Si) H6 CSI. The proposed H7 CSI takes the advantages of the SiC switch to maintain high efficiency, while significantly increasing the switching...... as an all-SiC-switch converter in terms of high performance and high efficiency with reduced DC inductance. It provides a cost-effective solution to addressing the efficiency issue of conventional CSI systems. Simulations and experiments are performed to validate the effectiveness of the proposed H7 CSI...

  15. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    Energy Technology Data Exchange (ETDEWEB)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael [University of Erlangen, Department of Radiology, Erlangen (Germany); Deak, Paul; Kalender, Willi A. [University of Erlangen, Department of Medical Physics, Erlangen (Germany); Keller, Andrea K.; Haeberle, Lothar [University of Erlangen, Department of Medical Informatics, Biometry and Epidemiology, Erlangen (Germany); Achenbach, Stephan; Seltmann, Martin [University of Erlangen, Department of Cardiology, Erlangen (Germany)

    2012-03-15

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 {+-} 2.1 mSv/100 mAs for TCM and 12.5 {+-} 5.3 mSv/100 mAs for CTC (P < 0.001). Relative dose reduction at low HR ({<=}60 bpm) was highest (49 {+-} 5%) compared to intermediate (60-70 bpm, 33 {+-} 12%) and high HR (>70 bpm, 29 {+-} 12%). However lowest ED is achieved at high HR (5.2 {+-} 1.5 mSv/100 mAs), compared with intermediate (6.7 {+-} 1.6 mSv/100 mAs) and low (8.3 {+-} 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  16. Radiation dose considerations by intra-individual Monte Carlo simulations in dual source spiral coronary computed tomography angiography with electrocardiogram-triggered tube current modulation and adaptive pitch

    International Nuclear Information System (INIS)

    May, Matthias S.; Kuettner, Axel; Lell, Michael M.; Wuest, Wolfgang; Scharf, Michael; Uder, Michael; Deak, Paul; Kalender, Willi A.; Keller, Andrea K.; Haeberle, Lothar; Achenbach, Stephan; Seltmann, Martin

    2012-01-01

    To evaluate radiation dose levels in patients undergoing spiral coronary computed tomography angiography (CTA) on a dual-source system in clinical routine. Coronary CTA was performed for 56 patients with electrocardiogram-triggered tube current modulation (TCM) and heart-rate (HR) dependent pitch adaptation. Individual Monte Carlo (MC) simulations were performed for dose assessment. Retrospective simulations with constant tube current (CTC) served as reference. Lung tissue was segmented and used for organ and effective dose (ED) calculation. Estimates for mean relative ED was 7.1 ± 2.1 mSv/100 mAs for TCM and 12.5 ± 5.3 mSv/100 mAs for CTC (P 70 bpm, 29 ± 12%). However lowest ED is achieved at high HR (5.2 ± 1.5 mSv/100 mAs), compared with intermediate (6.7 ± 1.6 mSv/100 mAs) and low (8.3 ± 2.1 mSv/100 mAs) HR when automated pitch adaptation is applied. Radiation dose savings up to 52% are achievable by TCM at low and regular HR. However lowest ED is attained at high HR by pitch adaptation despite inferior radiation dose reduction by TCM. circle Monte Carlo simulations allow for individual radiation dose calculations. (orig.)

  17. A 3 A sink/source current fast transient response low-dropout G{sub m} driven linear regulator

    Energy Technology Data Exchange (ETDEWEB)

    Chu Xiuqin; Li Qingwei; Lai Xinquan; Yuan Bing [Institute of Electronic CAD, Xidian University, Xi' an 710071 (China); Li Yanming [School of Electronic and Control Engineering, Chang' an University, Xi' an 710064 (China); Zhao Yongrui, E-mail: liqw309@163.com, E-mail: xqchu@mail.xidian.edu.cn [Key Laboratory of High-Speed Circuit Design and EMC, Ministry of Education, Xidian University, Xi' an 710071 (China)

    2011-06-15

    A 3 A sink/source G{sub m}-driven CMOS low-dropout regulator (LDO), specially designed for low input voltage and low cost, is presented by utilizing the structure of a current mirror G{sub m} (transconductance) driving technique, which provides high stability as well as a fast load transient response. The proposed LDO was fabricated by a 0.5 {mu}m standard CMOS process, and the die size is as small as 1.0 mm{sup 2}. The proposed LDO dissipates 220 {mu}A of quiescent current in no-load conditions and is able to deliver up to 3 A of load current. The measured results show that the output voltage can be resumed within 2 {mu}s with a less than 1 mV overshoot and undershoot in the output current step from -1.8 to 1.8 A with a 0.1 {mu}s rising and falling time at three 10 {mu}F ceramic capacitors. (semiconductor integrated circuits)

  18. A 3 A sink/source current fast transient response low-dropout Gm driven linear regulator

    International Nuclear Information System (INIS)

    Chu Xiuqin; Li Qingwei; Lai Xinquan; Yuan Bing; Li Yanming; Zhao Yongrui

    2011-01-01

    A 3 A sink/source G m -driven CMOS low-dropout regulator (LDO), specially designed for low input voltage and low cost, is presented by utilizing the structure of a current mirror G m (transconductance) driving technique, which provides high stability as well as a fast load transient response. The proposed LDO was fabricated by a 0.5 μm standard CMOS process, and the die size is as small as 1.0 mm 2 . The proposed LDO dissipates 220 μA of quiescent current in no-load conditions and is able to deliver up to 3 A of load current. The measured results show that the output voltage can be resumed within 2 μs with a less than 1 mV overshoot and undershoot in the output current step from -1.8 to 1.8 A with a 0.1 μs rising and falling time at three 10 μF ceramic capacitors. (semiconductor integrated circuits)

  19. CONTROLLING INFLUENCE OF MAGNETIC FIELD ON SOLAR WIND OUTFLOW: AN INVESTIGATION USING CURRENT SHEET SOURCE SURFACE MODEL

    Energy Technology Data Exchange (ETDEWEB)

    Poduval, B., E-mail: bpoduval@spacescience.org [Space Science Institute, Boulder, CO 80303 (United States)

    2016-08-10

    This Letter presents the results of an investigation into the controlling influence of large-scale magnetic field of the Sun in determining the solar wind outflow using two magnetostatic coronal models: current sheet source surface (CSSS) and potential field source surface. For this, we made use of the Wang and Sheeley inverse correlation between magnetic flux expansion rate (FTE) and observed solar wind speed (SWS) at 1 au. During the period of study, extended over solar cycle 23 and beginning of solar cycle 24, we found that the coefficients of the fitted quadratic equation representing the FTE–SWS inverse relation exhibited significant temporal variation, implying the changing pattern of the influence of FTE on SWS over time. A particularly noteworthy feature is an anomaly in the behavior of the fitted coefficients during the extended minimum, 2008–2010 (CRs 2073–2092), which is considered due to the particularly complex nature of the solar magnetic field during this period. However, this variation was significant only for the CSSS model, though not a systematic dependence on the phase of the solar cycle. Further, we noticed that the CSSS model demonstrated better solar wind prediction during the period of study, which we attribute to the treatment of volume and sheet currents throughout the corona and the more accurate tracing of footpoint locations resulting from the geometry of the model.

  20. Optimisation of intense X-ray sources of Z-pinch type connected to the high intensity current generator SPHINX

    International Nuclear Information System (INIS)

    Calamy, H.; Lassalle, F.; Grunenwald, J.; Zucchini, F.

    2010-01-01

    A new source of intense X-rays in the spectral range of the keV has been designed in the CEA facilities at Gramat (France). This Z-pinch source is based on the implosion of a cylinder of matter that has been ionized by the Lorentz force generated by the injection in the cylinder of an intense current pulse delivered by a HPP (High Pulsed Powers) generator named SPHINX. The cylinder of matter is made up of a few hundreds of thin metal wires (tungsten or aluminium) whose diameter is less than a few tenths of μm. The SPHINX generator is based on the LTD (Linear Transformer Driver) technology. SPHINX stores an energy of 2.2 MJ and delivers a current of 8 MA over a time of 1 μs. SPHINX does not use any technology of time compression, it is a robust, compact machine with reduced maintenance but the price to pay for this simplification is to maintain a high axial homogeneity of the implosion during the initiation phase, it means the pulse time of 1μs. The preliminary experiments that have been performed give the following results: -) for a tungsten cylinder (X ray 1 keV): 28 kJ, 0.6 TW and 25 ns

  1. Novel design of high voltage pulse source for efficient dielectric barrier discharge generation by using silicon diodes for alternating current

    Science.gov (United States)

    Truong, Hoa Thi; Hayashi, Misaki; Uesugi, Yoshihiko; Tanaka, Yasunori; Ishijima, Tatsuo

    2017-06-01

    This work focuses on design, construction, and optimization of configuration of a novel high voltage pulse power source for large-scale dielectric barrier discharge (DBD) generation. The pulses were generated by using the high-speed switching characteristic of an inexpensive device called silicon diodes for alternating current and the self-terminated characteristic of DBD. The operation started to be powered by a primary DC low voltage power supply flexibly equipped with a commercial DC power supply, or a battery, or DC output of an independent photovoltaic system without transformer employment. This flexible connection to different types of primary power supply could provide a promising solution for the application of DBD, especially in the area without power grid connection. The simple modular structure, non-control requirement, transformer elimination, and a minimum number of levels in voltage conversion could lead to a reduction in size, weight, simple maintenance, low cost of installation, and high scalability of a DBD generator. The performance of this pulse source has been validated by a load of resistor. A good agreement between theoretically estimated and experimentally measured responses has been achieved. The pulse source has also been successfully applied for an efficient DBD plasma generation.

  2. Topography, power, and current source density of θ oscillations during reward processing as markers for alcohol dependence.

    Science.gov (United States)

    Kamarajan, Chella; Rangaswamy, Madhavi; Manz, Niklas; Chorlian, David B; Pandey, Ashwini K; Roopesh, Bangalore N; Porjesz, Bernice

    2012-05-01

    Recent studies have linked alcoholism with a dysfunctional neural reward system. Although several electrophysiological studies have explored reward processing in healthy individuals, such studies in alcohol-dependent individuals are quite rare. The present study examines theta oscillations during reward processing in abstinent alcoholics. The electroencephalogram (EEG) was recorded in 38 abstinent alcoholics and 38 healthy controls as they performed a single outcome gambling task, which involved outcomes of either loss or gain of an amount (10 or 50¢) that was bet. Event-related theta band (3.0-7.0 Hz) power following each outcome stimulus was computed using the S-transform method. Theta power at the time window of the outcome-related negativity (ORN) and positivity (ORP) (200-500 ms) was compared across groups and outcome conditions. Additionally, behavioral data of impulsivity and task performance were analyzed. The alcoholic group showed significantly decreased theta power during reward processing compared to controls. Current source density (CSD) maps of alcoholics revealed weaker and diffuse source activity for all conditions and weaker bilateral prefrontal sources during the Loss 50 condition when compared with controls who manifested stronger and focused midline sources. Furthermore, alcoholics exhibited increased impulsivity and risk-taking on the behavioral measures. A strong association between reduced anterior theta power and impulsive task-performance was observed. It is suggested that decreased power and weaker and diffuse CSD in alcoholics may be due to dysfunctional neural reward circuitry. The relationship among alcoholism, theta oscillations, reward processing, and impulsivity could offer clues to understand brain circuitries that mediate reward processing and inhibitory control. Copyright © 2011 Wiley-Liss, Inc.

  3. Impact of the Diamond Light Source on research in Earth and environmental sciences: current work and future perspectives.

    Science.gov (United States)

    Burke, Ian T; Mosselmans, J Frederick W; Shaw, Samuel; Peacock, Caroline L; Benning, Liane G; Coker, Victoria S

    2015-03-06

    Diamond Light Source Ltd celebrated its 10th anniversary as a company in December 2012 and has now accepted user experiments for over 5 years. This paper describes the current facilities available at Diamond and future developments that enhance its capacities with respect to the Earth and environmental sciences. A review of relevant research conducted at Diamond thus far is provided. This highlights how synchrotron-based studies have brought about important advances in our understanding of the fundamental parameters controlling highly complex mineral-fluid-microbe interface reactions in the natural environment. This new knowledge not only enhances our understanding of global biogeochemical processes, but also provides the opportunity for interventions to be designed for environmental remediation and beneficial use.

  4. Simulation of 10 A electron-beam formation and collection for a high current electron-beam ion source

    International Nuclear Information System (INIS)

    Kponou, A.; Beebe, E.; Pikin, A.; Kuznetsov, G.; Batazova, M.; Tiunov, M.

    1998-01-01

    Presented is a report on the development of an electron-beam ion source (EBIS) for the relativistic heavy ion collider at Brookhaven National Laboratory (BNL) which requires operating with a 10 A electron beam. This is approximately an order of magnitude higher current than in any existing EBIS device. A test stand is presently being designed and constructed where EBIS components will be tested. It will be reported in a separate paper at this conference. The design of the 10 A electron gun, drift tubes, and electron collector requires extensive computer simulations. Calculations have been performed at Novosibirsk and BNL using two different programs, SAM and EGUN. Results of these simulations will be presented. copyright 1998 American Institute of Physics

  5. Simulation of 10 A electron-beam formation and collection for a high current electron-beam ion source

    Science.gov (United States)

    Kponou, A.; Beebe, E.; Pikin, A.; Kuznetsov, G.; Batazova, M.; Tiunov, M.

    1998-02-01

    Presented is a report on the development of an electron-beam ion source (EBIS) for the relativistic heavy ion collider at Brookhaven National Laboratory (BNL) which requires operating with a 10 A electron beam. This is approximately an order of magnitude higher current than in any existing EBIS device. A test stand is presently being designed and constructed where EBIS components will be tested. It will be reported in a separate paper at this conference. The design of the 10 A electron gun, drift tubes, and electron collector requires extensive computer simulations. Calculations have been performed at Novosibirsk and BNL using two different programs, SAM and EGUN. Results of these simulations will be presented.

  6. Developmental activities of the 18 GHz high temperature superconducting ECR ion source, PKDELIS, for the high current injector at IUAC

    International Nuclear Information System (INIS)

    Rodrigues, G.; Lakshmy, P.S.; Mathur, Y.; Ahuja, R.; Dutt, R.N.; Rao, U.K.; Mandal, A.; Kanjilal, D.; Roy, A.

    2011-01-01

    Various developmental activities of the 18 GHz High Temperature Superconducting ECR Ion Source, PKDELIS have been carried out as a part of the High Current Injector programme. Emittance measurements using a simple technique has given important inputs for the design of downstream accelerators like RFQ, DTL and low beta cavities. The techniques allows for emittance matching by varying the emittance parameters to match with the acceptance of the accelerators. X-ray Beamstrahlung measurements from ECR plasma has shown that it is a diagnostic tool to optimize the production of highly charged ions. The ion optics through the low energy beam transport section has been benchmarked with various codes and given a handle to optimize the transmission. New techniques to improve the extraction efficiency of highly charged ions has been developed. (author)

  7. Seasonal characteristics and current sources of OCPs and PCBs and enantiomeric signatures of chiral OCPs in the atmosphere of Vietnam.

    Science.gov (United States)

    Wang, Weitao; Wang, Yinghui; Zhang, Ruijie; Wang, Shaopeng; Wei, Chaoshuai; Chaemfa, Chakra; Li, Jun; Zhang, Gan; Yu, Kefu

    2016-01-15

    Passive air samplers (PAS) were deployed concurrently at 15 locations (nine urban sites and six rural sites) in Vietnam and exposed for approximately 6 weeks from June 26, 2012 to August 26, 2012 and from December 8, 2012 to February 8, 2013. The concentration, composition and enantiomeric signatures of the target compound and Air Mass Backward Trajectories of the 15 sampling sites are presented and discussed in this study. Relatively clean air mass from ocean and similar concentrations and composition of POPs between the south and north of Vietnam indicate that local emissions is most likely the major source of POPs in Vietnam. Technical DDT and technical HCH were widely used in Vietnam and corresponding quantitative data suggests the sporadic use. The preferential degradation of (+)-α-HCH was found in all sampling sites, which could be a regional characteristic of Vietnam. High trans-/cis-chlordane (TC/CC) ratios indicate the current use of technical chlordane for termite control. PCA estimated that main source of PCBs present in the atmosphere of Vietnam was uncontrolled discarded e-waste. Copyright © 2015 Elsevier B.V. All rights reserved.

  8. Dietary fibre in Europe: current state of knowledge on definitions, sources, recommendations, intakes and relationships to health.

    Science.gov (United States)

    Stephen, Alison M; Champ, Martine M-J; Cloran, Susan J; Fleith, Mathilde; van Lieshout, Lilou; Mejborn, Heddie; Burley, Victoria J

    2017-12-01

    Research into the analysis, physical properties and health effects of dietary fibre has continued steadily over the last 40-50 years. From the knowledge gained, countries have developed guidelines for their populations on the optimal amount of fibre to be consumed each day. Food composition tables from many countries now contain values for the dietary fibre content of foods, and, from these, combined with dietary surveys, population intakes have been determined. The present review assessed the uniformity of the analytical methods used, health claims permitted, recommendations and intakes, particularly from national surveys across Europe and around the world. It also assessed current knowledge on health effects of dietary fibre and related the impact of different fibre types on health. The overall intent was to be able to provide more detailed guidance on the types of fibre which should be consumed for good health, rather than simply a total intake figure, the current situation. Analysis of data indicated a fair degree of uniformity in the definition of dietary fibre, the method used for analysis, the recommended amount to be consumed and a growing literature on effects on digestive health and disease risk. However, national dietary survey data showed that intakes do not reach recommendations and very few countries provide guidance on the types of fibre that are preferable to achieve recommended intakes. Research gaps were identified and ideas suggested to provide information for more detailed advice to the public about specific food sources that should be consumed to achieve health benefits.

  9. Sustained attention in skilled and novice martial arts athletes: a study of event-related potentials and current sources.

    Science.gov (United States)

    Sanchez-Lopez, Javier; Silva-Pereyra, Juan; Fernandez, Thalia

    2016-01-01

    Background. Research on sports has revealed that behavioral responses and event-related brain potentials (ERP) are better in expert than in novice athletes for sport-related tasks. Focused attention is essential for optimal athletic performance across different sports but mainly in combat disciplines. During combat, long periods of focused attention (i.e., sustained attention) are required for a good performance. Few investigations have reported effects of expertise on brain electrical activity and its neural generators during sport-unrelated attention tasks. The aim of the present study was to assess the effect of expertise (i.e., skilled and novice martial arts athletes) analyzing the ERP during a sustained attention task (Continuous Performance Task; CPT) and the cortical three-dimensional distribution of current density, using the sLORETA technique. Methods. CPT consisted in an oddball-type paradigm presentation of five stimuli (different pointing arrows) where only one of them (an arrow pointing up right) required a motor response (i.e., target). CPT was administered to skilled and novice martial arts athletes while EEG were recorded. Amplitude ERP data from target and non-target stimuli were compared between groups. Subsequently, current source analysis for each ERP component was performed on each subject. sLORETA images were compared by condition and group using Statistical Non-Parametric Mapping analysis. Results. Skilled athletes showed significant amplitude differences between target and non-target conditions in early ERP components (P100 and P200) as opposed to the novice group; however, skilled athletes showed no significant effect of condition in N200 but novices did show a significant effect. Current source analysis showed greater differences in activations in skilled compared with novice athletes between conditions in the frontal (mainly in the Superior Frontal Gyrus and Medial Frontal Gyrus) and limbic (mainly in the Anterior Cingulate Gyrus) lobes

  10. Current Background Noise Sources and Levels in the NASA Ames 40- by 80-Foot Wind Tunnel: A Status Report

    Science.gov (United States)

    Allen, Christopher S.; Jaeger, Stephen; Soderman, Paul; Koga, Dennis (Technical Monitor)

    1999-01-01

    Background noise measurements were made of the acoustic environment in the National Full-Scale Aerodynamics Complex 40- by 80-Foot Wind Tunnel (40x80) at NASA Ames Research Center. The measurements were acquired subsequent to the 40x80 Aeroacoustic Modernization Project, which was undertaken to improve the anechoic characteristics of the 40x80's closed test section as well as reduce the levels of background noise in the facility. The resulting 40x80 anechoic environment was described by Soderman et. al., and the current paper describes the resulting 40x80 background noise, discusses the sources of the noise, and draws comparisons to previous 40x80 background noise levels measurements. At low wind speeds or low frequencies, the 40x80 background noise is dominated by the fan drive system. To obtain the lowest fan drive noise for a given tunnel condition, it is possible in the 40x80 to reduce the fans' rotational speed and adjust the fans' blade pitch, as described by Schmidtz et. al. This idea is not new, but has now been operationally implemented with modifications for increased power at low rotational speeds. At low to mid-frequencies and at higher wind speeds, the dominant noise mechanism was thought to be caused by the surface interface of the previous test section floor acoustic lining. In order to reduce this noise mechanism, the new test section floor lining was designed to resist the pumping of flow in and out of the space between the grating slats required to support heavy equipment. In addition, the lining/flow interface over the entire test section was designed to be smoother and quieter than the previous design. At high wind speeds or high frequencies, the dominant source of background noise in the 40x80 is believed to be caused by the response of the in-flow microphone probes (required by the nature of the closed test section) to the fluctuations in the freestream flow. The resulting background noise levels are also different for probes of various

  11. Sediment source fingerprinting as an aid to catchment management: A review of the current state of knowledge and a methodological decision-tree for end-users

    Science.gov (United States)

    Collins, A.L; Pulley, S.; Foster, I.D.L; Gellis, Allen; Porto, P.; Horowitz, A.J.

    2017-01-01

    The growing awareness of the environmental significance of fine-grained sediment fluxes through catchment systems continues to underscore the need for reliable information on the principal sources of this material. Source estimates are difficult to obtain using traditional monitoring techniques, but sediment source fingerprinting or tracing procedures, have emerged as a potentially valuable alternative. Despite the rapidly increasing numbers of studies reporting the use of sediment source fingerprinting, several key challenges and uncertainties continue to hamper consensus among the international scientific community on key components of the existing methodological procedures. Accordingly, this contribution reviews and presents recent developments for several key aspects of fingerprinting, namely: sediment source classification, catchment source and target sediment sampling, tracer selection, grain size issues, tracer conservatism, source apportionment modelling, and assessment of source predictions using artificial mixtures. Finally, a decision-tree representing the current state of knowledge is presented, to guide end-users in applying the fingerprinting approach.

  12. Optimization of the plasma parameters for the high current and uniform large-scale pulse arc ion source of the VEST-NBI system

    International Nuclear Information System (INIS)

    Jung, Bongki; Park, Min; Heo, Sung Ryul; Kim, Tae-Seong; Jeong, Seung Ho; Chang, Doo-Hee; Lee, Kwang Won; In, Sang-Ryul

    2016-01-01

    Highlights: • High power magnetic bucket-type arc plasma source for the VEST NBI system is developed with modifications based on the prototype plasma source for KSTAR. • Plasma parameters in pulse duration are measured to characterize the plasma source. • High plasma density and good uniformity is achieved at the low operating pressure below 1 Pa. • Required ion beam current density is confirmed by analysis of plasma parameters and results of a particle balance model. - Abstract: A large-scale hydrogen arc plasma source was developed at the Korea Atomic Energy Research Institute for a high power pulsed NBI system of VEST which is a compact spherical tokamak at Seoul national university. One of the research target of VEST is to study innovative tokamak operating scenarios. For this purpose, high current density and uniform large-scale pulse plasma source is required to satisfy the target ion beam power efficiently. Therefore, optimizing the plasma parameters of the ion source such as the electron density, temperature, and plasma uniformity is conducted by changing the operating conditions of the plasma source. Furthermore, ion species of the hydrogen plasma source are analyzed using a particle balance model to increase the monatomic fraction which is another essential parameter for increasing the ion beam current density. Conclusively, efficient operating conditions are presented from the results of the optimized plasma parameters and the extractable ion beam current is calculated.

  13. Dynamics of a lightning corona sheath—A constant field approach using the generalized traveling current source return stroke model

    Science.gov (United States)

    Cvetic, Jovan; Heidler, Fridolin; Markovic, Slavoljub; Radosavljevic, Radovan; Osmokrovic, Predrag

    2012-11-01

    A generalized lightning traveling current source return stroke model has been used to examine the characteristics of the lightning channel corona sheath surrounding a thin channel core. A model of the lightning channel consisting of a charged corona sheath and a narrow, highly conducting central core that conducts the main current flow is assumed. Strong electric field, with a predominant radial direction, has been created during the return stroke between the channel core and the outer channel sheath containing the negative charge. The return stroke process is modeled with the positive charge coming from the channel core discharging the negative leader charge in the corona sheath. The corona sheath model that predicts the charge motion in the sheath is used to derive the expressions of the sheath radius vs. time during the return stroke. According to the corona sheath model proposed earlier by Maslowski and Rakov (2006) and Maslowski et al. (2009), it consists of three zones, zone 1 (surrounding channel core with net positive charge), zone 2 (surrounding zone 1 with negative charge) and zone 3 (outer zone representing the virgin air without charges). We adopted the assumption of a constant electric field inside zone 1 of the corona sheath observed in the experimental research of corona discharges in a coaxial geometry by Cooray (2000). This assumption seems to be more realistic than the assumption of a uniform corona space charge density used previously in the study of Maslowski and Rakov (2006), Marjanovic and Cvetic (2009), and Tausanovic et al. (2010). Applying the Gauss' law on the infinitesimally small cylindrical section of the channel the expressions for time-dependence of the radii of zones 1 and 2 during the return stroke are derived. The calculations have shown that the overall channel dynamics concerning electrical discharge is roughly 50% slower and the maximum radius of zone 1 is about 33% smaller compared to the corresponding values calculated in the

  14. Design of a CMOS temperature sensor with current output

    NARCIS (Netherlands)

    Kolling, A.; Kölling, Arjan; Bak, Frans; Bergveld, Piet; Seevinck, E.; Seevinck, Evert

    1990-01-01

    In this paper a CMOS temperature-to-current converter is presented of which the output current is the difference between a PTC current and an NTC current. The PTC current is derived from a PTAT cell, while the NTC current is derived from a threshold voltage reference source. It is shown that this

  15. Neptunium: a bibliographic reference

    International Nuclear Information System (INIS)

    Mosley, R.E.

    1979-06-01

    A comprehensive bibliograhy of the literature on the element neptunium published prior to January 1976 is presented. A short abstract is given for each listed reference, with a few exceptions. The references are divided into sections categorized as General, Man-Made Sources (Reactors), Man-Made Sources (Fuel Reprocessing), Chemistry (Solubility), Chemistry (Compounds), Chemistry (Isotopes), Analyses (Instrumental), Analyses (Chemical), Chemical (Animal), Biological (Effects), Biological (Animal-Metabolism-Retention), Biological (Air Movement), Biological (Human Inhalation), Measurement, and Dosimetry. The bibliography contains author and keyword indexes and was compiled to serve as a quick reference source for neptunium-related work. 184 citations

  16. Development of soft ionization using direct current pulse glow discharge plasma source in mass spectrometry for volatile organic compounds analysis

    Science.gov (United States)

    Nunome, Yoko; Kodama, Kenji; Ueki, Yasuaki; Yoshiie, Ryo; Naruse, Ichiro; Wagatsuma, Kazuaki

    2018-01-01

    This study describes an ionization source for mass analysis, consisting of glow discharge plasma driven by a pulsed direct-current voltage for soft plasma ionization, to detect toxic volatile organic compounds (VOCs) rapidly and easily. The novelty of this work is that a molecular adduct ion, in which the parent molecule attaches with an NO+ radical, [M + NO]+, can be dominantly detected as a base peak with little or no fragmentation of them in an ambient air plasma at a pressure of several kPa. Use of ambient air as the discharge plasma gas is suitable for practical applications. The higher pressure in an ambient air discharge provided a stable glow discharge plasma, contributing to the soft ionization of organic molecules. Typical mass spectra of VOCs toluene, benzene, o-xylene, chlorobenzene and n-hexane were observed as [M + NO]+ adduct ion whose peaks were detected at m/z 122, 108, 136, 142 and 116, respectively. The NO generation was also confirmed by emission bands of NO γ-system. The ionization reactions were suggested, such that NO+ radical formed in an ambient air discharge could attach with the analyte molecule.

  17. Clinical thermometry, using the 27 MHz multi-electrode current-source interstitial hyperthermia system in brain tumours

    International Nuclear Information System (INIS)

    Kaatee, Robert S.J.P.; Nowak, Peter C.J.M.; Zee, Jacoba van der; Bree, Jacob de; Kanis, Bart P.; Crezee, Hans; Levendag, Peter C.; Visser, Andries G.

    2001-01-01

    Background and purpose: In interstitial hyperthermia, temperature measurements are mainly performed inside heating applicators, and therefore, give the maximum temperatures of a rather heterogeneous temperature distribution. The problem of how to estimate lesion temperatures using the multi-electrode current-source interstitial hyperthermia (MECS-IHT) system in the brain was studied. Materials and methods: Temperatures were measured within the electrodes and in an extra catheter at the edge of a 4x4x4.5 cm 3 glioblastoma multiforme resection cavity. From the temperature decays during a power-off period, information was obtained about local maximum and minimum tissue temperatures. The significance of these data was examined through model calculations. Results: Maximum tissue temperatures could be estimated roughly by switching off all electrodes for about 5 s. Model calculations showed that the minimum tissue temperatures near a certain afterloading catheter correspond well with the temperature of the applicator inside, about 1 min after this applicator was switched off. Conclusions: Although the electrode temperatures read during heating are not suitable to assess the temperature distribution, it is feasible to heat the brain adequately using the MECS-IHT system with extra sensors outside the electrodes and/or application of decay methods

  18. The physics and technology of ion sources

    International Nuclear Information System (INIS)

    Brown, I.G.

    1989-01-01

    New applications call for ion beams of unprecedented energy, current, species, focus, uniformity, size, and charge states. This comprehensive, up-to-date review and reference for the rapidly evolving field of ion source technology relates improvements to traditional ion sources and describes the development of the new kinds of ion sources. Also provides background material on the physics of ion sources. Chapters are self-contained, making for easy reference

  19. Reference sources for the calibration of surface contamination monitors - Beta-emitters (maximum beta energy greater than MeV) and alpha-emitters (International Standard Publication ISO 8769:1988)

    International Nuclear Information System (INIS)

    Stefanik, J.

    2001-01-01

    This International Standard specifies the characteristics of reference sources of radioactive surface contamination, traceable to national measurement standards, for the calibration of surface contamination monitors. This International Standard relates to alpha-emitters and to beta-emitters of maximum beta energy greater than 0,15 MeV. It does not describe the procedures involved in the use of these reference sources for the calibration of surface contamination monitors. Such procedures are specified in IEC Publication 325 and other documents. This International Standard specifies reference radiations for the calibration of surface contamination monitors which take the form of adequately characterized large area sources specified, without exception, in terms of activity and surface emission rate, the evaluation of these quantities being traceable to national standards

  20. SU-F-T-276: Source Modeling and VMAT Quality Assurance Referring to the TrueBeam Representative Beam Data for Eclipse

    Energy Technology Data Exchange (ETDEWEB)

    Wu, Q [Beijing Hospital, Beijing (China)

    2016-06-15

    Purpose: To study quality assurance (QA) of volumetric modulated arc therapy (VMAT) after the 6MV and 10MV photon beam source modeling, referring to the Varian TrueBeam representative beam data for Eclipse. Methods: The source model needs specific measured beam data, such as PDDs and profiles, diagonal profile, output factors (OFs), and MLC transmission factor (TF) and dosimetric leaf gap (DLG), et al. We downloaded the representative data from myVarian website, which includes TrueBeam 4MV-15MV photon beam data and 6MeV-22MeV electron beam data in w2CAD file format for use with Eclipse and in Excel spreadsheet format for use in data comparison. The beam data in W2CAD format can be imported into the Eclipse system and calibrated for use, as appropriate. We used PTW MP3 water tank to measure the beam data in some typical field sizes, and compared the measured data with the representative data. We found that the PDDs, profiles and OFs are similar. However according to some papers and our measurements, we decided that our MLC TF and DLG are 1.58 and 1.33 (6MV), 1.79 and 1.57 (10MV), respectively. After we had configured the anisotropic analytical algorithm (AAA) with the representative data in Eclipse, we also have done dosimetric verification for 88 VMAT plans. Results: The end-to-end test procedures of VMAT were performed for 6MV and 10MV energy modes. The NE Farmer ion chamber mean measurements showed 1.2% (6MV, 38 cases) and 1.2% (10MV, 50 cases) between measurement and calculation; the Sun Nuclear ArcCheck mean measurements demonstrated gamma pass rates are as followings: 98.9%, 93.2%, 61.0% for 6MV, and 98.9%, 91.9%, 59.5% for 10MV, using 3%/3mm, 2%/2mm, 1%/1mm, 10% threshold criteria, respectively. Conclusion: The representative data is applicable to our TrueBeam for the VMAT plan, though our MLC factors are a little different, and its patientspecific QA is good.

  1. Tank characterization reference guide

    International Nuclear Information System (INIS)

    De Lorenzo, D.S.; DiCenso, A.T.; Hiller, D.B.; Johnson, K.W.; Rutherford, J.H.; Smith, D.J.; Simpson, B.C.

    1994-09-01

    Characterization of the Hanford Site high-level waste storage tanks supports safety issue resolution; operations and maintenance requirements; and retrieval, pretreatment, vitrification, and disposal technology development. Technical, historical, and programmatic information about the waste tanks is often scattered among many sources, if it is documented at all. This Tank Characterization Reference Guide, therefore, serves as a common location for much of the generic tank information that is otherwise contained in many documents. The report is intended to be an introduction to the issues and history surrounding the generation, storage, and management of the liquid process wastes, and a presentation of the sampling, analysis, and modeling activities that support the current waste characterization. This report should provide a basis upon which those unfamiliar with the Hanford Site tank farms can start their research

  2. Estimation of Completeness of Cancer Registration for Patients Referred to Shiraz Selected Centers through a Two Source Capture Re-capture Method, 2009 Data.

    Science.gov (United States)

    Sharifian, Roxana; SedaghatNia, Mohammad Hossein; Nematolahi, Mohtram; Zare, Najaf; Barzegari, Saeed

    2015-01-01

    Cancer has important social consequences with cancer registration as the basis of moving towards prevention. The present study aimed to estimate the completeness of registration of the ten most common cancers in patients referred to selected hospitals in Shiraz, Iran by using capture-recapture method. This cross-sectional analytical study was performed in 2014 based on the data of 2009, on a total of 4,388 registered cancer patients. After cleaning data from two sources, using capture-recapture common findings were identified. Then, the percentage of the completeness of cancer registration was estimated using Chapman and Chao methods. Finally, the effects of demographic and treatment variables on the completeness of cancer registration were investigated. The results showed that the percentages of completeness of cancer registration in the selected hospitals of Shiraz were 58.6% and 58.4%, and influenced by different variables. The age group between 40-49 years old was the highest represented and for the age group under 20 years old was the lowest for cancer registration. Breast cancer had the highest registration level and after that, thyroid and lung cancers, while colorectal cancer had the lowest registration level. According to the results, the number of cancers registered was very few and it seems that factors like inadequate knowledge of some doctors, imprecise diagnosis about the types of cancer, incorrectly filled out medical documents, and lack of sufficient accuracy in recording data on the computer cause errors and defects in cancer registration. This suggests a necessity to educate and teach doctors and other medical workers about the methods of documenting information related to cancer and also conduct additional measures to improve the cancer registration system.

  3. Survey of currently available reference materials for use in connection with the determination of trace elements in biological and environmental materials

    International Nuclear Information System (INIS)

    Muramatsu, Y.; Parr, R.M.

    1985-12-01

    This report focuses on analytical reference materials which have been developed for use in connection with the determination of toxic and essential trace elements in biomedical and health-related environmental samples. Data are reported on 60 biological and 40 environmental (non-biological) reference materials from 11 suppliers. Certified concentration values (or their equivalents) and non-certified concentration values (or information values) are presented in various tables which are intended to help the user select a reference material that matches as closely as possible (i.e. with respect to matrix type and concentration of the element of interest) the ''real'' samples that are to be analysed. These tables have been generated from a database characterized by the following parameters: total number of reference materials=100; total number of elements recorded=69; total number of concentration values recorded=1771. Also included in the report is information (where available) on the cost of each material, the unit weight or volume supplied, and the minimum weight of material recommended for analysis. (author)

  4. High performance predictive current control of a three phase VSI: An ...

    Indian Academy of Sciences (India)

    ... current control of a three phase VSI: An experimental assessment ... Voltage source inverter; two level inverter; predictive current control; weighting factor ... Conventionally, for reference current tracking control in a two level VSI, the objective ...

  5. Growth references

    NARCIS (Netherlands)

    Buuren, S. van

    2007-01-01

    A growth reference describes the variation of an anthropometric measurement within a group of individuals. A reference is a tool for grouping and analyzing data and provides a common basis for comparing populations.1 A well known type of reference is the age-conditional growth diagram. The

  6. Generic inertia emulation controller for multi-terminal voltage-source-converter high voltage direct current systems

    DEFF Research Database (Denmark)

    Zhu, Jiebei; Guerrero, Josep M.; Hung, William

    2014-01-01

    A generic Inertia Emulation Controller (INEC) scheme for Multi-Terminal Voltage-Source-Converter based HVDC (VSC-MTDC) systems is proposed and presented in this paper. The proposed INEC can be incorporated in any Grid-side Voltage-Source-Converter (GVSC) station, allowing the MTDC terminal...

  7. Novel family of quasi-Z-source DC/DC converters derived from current-fed push-pull converters

    DEFF Research Database (Denmark)

    Chub, Andrii; Husev, Oleksandr; Vinnikov, Dmitri

    2014-01-01

    This paper is devoted to the step-up quasi-Z-source dc/dc push-pull converter family. The topologies in the family are derived from the isolated boost converter family by replacing input inductors with the quasi-Z-source network. Two new topologies are proposed, analyzed and compared. Theoretical...

  8. Selection and evaluation of reference genes for RT-qPCR expression studies on Burkholderia tropica strain Ppe8, a sugarcane-associated diazotrophic bacterium grown with different carbon sources or sugarcane juice.

    Science.gov (United States)

    da Silva, Paula Renata Alves; Vidal, Marcia Soares; de Paula Soares, Cleiton; Polese, Valéria; Simões-Araújo, Jean Luís; Baldani, José Ivo

    2016-11-01

    Among the members of the genus Burkholderia, Burkholderia tropica has the ability to fix nitrogen and promote sugarcane plant growth as well as act as a biological control agent. There is little information about how this bacterium metabolizes carbohydrates as well as those carbon sources found in the sugarcane juice that accumulates in stems during plant growth. Reverse transcription quantitative PCR (RT-qPCR) can be used to evaluate changes in gene expression during bacterial growth on different carbon sources. Here we tested the expression of six reference genes, lpxC, gyrB, recA, rpoA, rpoB, and rpoD, when cells were grown with glucose, fructose, sucrose, mannitol, aconitic acid, and sugarcane juice as carbon sources. The lpxC, gyrB, and recA were selected as the most stable reference genes based on geNorm and NormFinder software analyses. Validation of these three reference genes during strain Ppe8 growth on the same carbon sources showed that genes involved in glycogen biosynthesis (glgA, glgB, glgC) and trehalose biosynthesis (treY and treZ) were highly expressed when Ppe8 was grown in aconitic acid relative to other carbon sources, while otsA expression (trehalose biosynthesis) was reduced with all carbon sources. In addition, the expression level of the ORF_6066 (gluconolactonase) gene was reduced on sugarcane juice. The results confirmed the stability of the three selected reference genes (lpxC, gyrB, and recA) during the RT-qPCR and also their robustness by evaluating the relative expression of genes involved in glycogen and trehalose biosynthesis when strain Ppe8 was grown on different carbon sources and sugarcane juice.

  9. A Method of Maximum Power Control in Single-phase Utility Interactive Photovoltaic Generation System by using PWM Current Source Inverter

    Science.gov (United States)

    Neba, Yasuhiko

    This paper deals with a maximum power point tracking (MPPT) control of the photovoltaic generation with the single-phase utility interactive inverter. The photovoltaic arrays are connected by employing the PWM current source inverter to the utility. The use of the pulsating dc current and voltage allows the maximum power point to be searched. The inverter can regulate the array voltage and keep the arrays to the maximum power. This paper gives the control method and the experimental results.

  10. High-Bandwidth, High-Efficiency Envelope Tracking Power Supply for 40W RF Power Amplifier Using Paralleled Bandpass Current Sources

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a high-performance power conversion scheme for power supply applications that require very high output voltage slew rates (dV/dt). The concept is to parallel 2 switching bandpass current sources, each optimized for its passband frequency space and the expected load current....... The principle is demonstrated with a power supply, designed for supplying a 40 W linear RF power amplifier for efficient amplification of a 16-QAM modulated data stream...

  11. Electron cyclotron resonance ion source for high currents of mono- and multicharged ion and general purpose unlimited lifetime application on implantation devices

    Science.gov (United States)

    Bieth, C.; Bouly, J. L.; Curdy, J. C.; Kantas, S.; Sortais, P.; Sole, P.; Vieux-Rochaz, J. L.

    2000-02-01

    The electron cyclotron resonance (ECR) ion sources were originally developed for high energy physic applications. They are used as injectors on linear accelerators and cyclotrons to further increase the particle energy via high charge state ions. This ECR technology is well suited for sources placed on a high voltage platform where ac power available is limited by insulated transformers. The PANTECHNIK family of ion source with its wide range of ion beam (various charge states with various beam currents) offers new possibilities and perspectives in the field of ion implantation. In addition to all these possibilities, the PANTECHNIK ion sources have many other advantages like: a very long lifetime without maintenance expense, good stability, efficiency of ionization close to 100% (this improves the lifetime of the pumping system and other equipment), the possibility of producing ion beams with different energies, and a very good reproducibility. The main characteristics of sources like Nanogan or SuperNanogan will be recalled. We will especially present the results obtained with the new Microgan 10 GHz source that can be optimized for the production of high currents of monocharged ion, including reactive gas like BF3 (2 mA e of B+) or medium currents of low charge state like 0.5 mA e of Ar4+. The latest results obtained with Microgan 10 GHz show that it is possible to drive the source up to 30 mA e of total current, with an emittance of 150 π mm mrad at 40 kV and also to maintain the production of multicharged ions like Ar8+.

  12. [Reference citation].

    Science.gov (United States)

    Brkić, Silvija

    2013-01-01

    Scientific and professional papers represent the information basis for scientific research and professional work. References important for the paper should be cited within the text, and listed at the end of the paper. This paper deals with different styles of reference citation. Special emphasis was placed on the Vancouver Style for reference citation in biomedical journals established by the International Committee of Medical Journal Editors. It includes original samples for citing various types of articles, both printed and electronic, as well as recommendations related to reference citation in accordance with the methodology and ethics of scientific research and guidelines for preparing manuscripts for publication.

  13. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich...

  14. Experimental Section: On the magnetic field distribution generated by a dipolar current source situated in a realistically shaped compartment model of the head

    NARCIS (Netherlands)

    Meijs, J.W.H.; Bosch, F.G.C.; Peters, M.J.; Lopes da silva, F.H.

    1987-01-01

    The magnetic field distribution around the head is simulated using a realistically shaped compartment model of the head. The model is based on magnetic resonance images. The 3 compartments describe the brain, the skull and the scalp. The source is represented by a current dipole situated in the

  15. Financing Adult Education: How Adequate Are Current Sources in Facilitating Access and Participation in Centres in Murang'a South Sub-County, Murang'a County, Kenya?

    Science.gov (United States)

    Maina, Ndonga James; Orodho, John Aluko

    2016-01-01

    The thrust of this study was to examine the level of adequacy of current sources in facilitating access and participation in adult education centres in Murang'a South Sub-County, Murang'a County, Kenya. The study adopted the descriptive survey design. Combinations of purposive and stratified random sampling techniques were used to select 82…

  16. Analysis of Expediency to Apply LCL Model with Source of Higher Harmonics of Current While Investigating Resonance Condition of Power Supply Network

    OpenAIRE

    M. Pavlovsky; A. Shimansky; Z. Fialkovsky

    2004-01-01

    The paper considers a power system model of a plant with one capacitor bank and with one current source of higher harmonics for higher power factor. The laboratory research results of this system and practical application of the proposed model are given in the paper.

  17. Analysis of Expediency to Apply LCL Model with Source of Higher Harmonics of Current While Investigating Resonance Condition of Power Supply Network

    Directory of Open Access Journals (Sweden)

    M. Pavlovsky

    2004-01-01

    Full Text Available The paper considers a power system model of a plant with one capacitor bank and with one current source of higher harmonics for higher power factor. The laboratory research results of this system and practical application of the proposed model are given in the paper.

  18. Optimum extracted H- and D- current densities from gas-pressure-limited high-power hydrogen/deuterium tandem ion sources

    International Nuclear Information System (INIS)

    Hiskes, J.R.

    1993-01-01

    The tandem hydrogen/deuterium ion source is modelled for the purpose of identifying the maximum current densities that can be extracted subject to the gas-pressure constraints proposed for contemporary beam-line systems. Optimum useful extracted current densities are found to be in the range of approximately 7 to 10 mA cm -2 . The sensitivity of these current densities is examined subject to uncertainties in the underlying atomic/molecular rate processes; A principal uncertainty remains the quantification of the molecular vibrational distribution following H 3 + wall collisions

  19. Study of electron current extraction from a radio frequency plasma cathode designed as a neutralizer for ion source applications

    Energy Technology Data Exchange (ETDEWEB)

    Jahanbakhsh, Sina, E-mail: sinajahanbakhsh@gmail.com; Satir, Mert; Celik, Murat [Department of Mechanical Engineering, Bogazici University, Istanbul 34342 (Turkey)

    2016-02-15

    Plasma cathodes are insert free devices that are developed to be employed as electron sources in electric propulsion and ion source applications as practical alternatives to more commonly used hollow cathodes. Inductively coupled plasma cathodes, or Radio Frequency (RF) plasma cathodes, are introduced in recent years. Because of its compact geometry, and simple and efficient plasma generation, RF plasma source is considered to be suitable for plasma cathode applications. In this study, numerous RF plasma cathodes have been designed and manufactured. Experimental measurements have been conducted to study the effects of geometric and operational parameters. Experimental results of this study show that the plasma generation and electron extraction characteristics of the RF plasma cathode device strongly depend on the geometric parameters such as chamber diameter, chamber length, orifice diameter, orifice length, as well as the operational parameters such as RF power and gas mass flow rate.

  20. Status of the high current permanent magnet 2.45 GHz ECR ion source at Peking University

    International Nuclear Information System (INIS)

    Peng, S.X.; Song, Z.Z.; Yu, J.X.; Ren, H.T.; Zhang, M.; Yuan, Z.X.; Lu, P.N.; Zhao, J.; Chen, J.E.; Guo, Z.Y.; Lu, Y.R.

    2012-01-01

    Several compact 2.45 GHz Electron Cyclotron Resonance Ion Sources (ECRIS) have been developed at Peking University for ion implantation, for the Separated Function Radio Frequency Quadrupole project (SFRFQ) and for the Peking University Neutron Imaging Facility project (PKUNIFTY). Studies on 2.45 GHz ECR ion sources are concentrated on methods of microwave coupling and microwave window design, magnetic field generation and configuration, as well as the extraction electrodes structure. Investigation also covers the influence of the size of plasma chamber on the discharge efficiency and species factor. Up to now, our sources have produced 25 mA of O + ions, 40 mA of He + ions, 10 mA of N + ions, 100 mA of H + ions and 83 mA of D + ions, respectively. The paper is followed by the slides of the presentation. (authors)

  1. Influence of Wall-Current-Compensation and Secondary-Electron-Emission on the Plasma Parameters and on the Performance of Electron Cyclotron Resonance Ion Sources

    International Nuclear Information System (INIS)

    Schachter, L.; Dobrescu, S.; Stiebing, K.E.

    2005-01-01

    Axial and radial diffusion processes determine the confinement time in an ECRIS. It has been demonstrated that a biased disk redirects the ion- and electron currents in the source in such a way that the source performance is improved. This effect is due to a partial cancellation of the compensating currents in the conductive walls of the plasma chamber.In this contribution we present an experiment, where these currents were effectively suppressed by using a metal-dielectric (MD) disk instead of the standard metallic disk in the Frankfurt 14-GHz-ECRIS. Lower values of the plasma potential and higher average charge states in the presence of the MD disk as compared to the case of the standard disk indicate that, due to the insulating properties of its dielectric layer the MD disk obviously blocks compensating wall currents better than applying bias to the metallic standard disk.A comparison with results from experiments with a MD liner in the source, covering essentially the complete radial walls of the plasma chamber, clearly demonstrates that the beneficial effect of the liner on the performance of the ECRIS is much stronger than that observed with the MD-disk. In accord with our earlier interpretation, it has to be concluded that the 'liner-effect' is not just the effect of blocking the compensating wall currents but rather has to be ascribed to the unique property of the thin MD liner as a strong secondary electron emitter under bombardment by charged particles

  2. Reference Assessment

    Science.gov (United States)

    Bivens-Tatum, Wayne

    2006-01-01

    This article presents interesting articles that explore several different areas of reference assessment, including practical case studies and theoretical articles that address a range of issues such as librarian behavior, patron satisfaction, virtual reference, or evaluation design. They include: (1) "Evaluating the Quality of a Chat Service"…

  3. Improved power simulation of AlGaN/GaN HEMT at class-AB operation via an RF drain—source current correction method

    International Nuclear Information System (INIS)

    Pongthavornkamol Tiwat; Pang Lei; Yuan Ting-Ting; Liu Xin-Yu

    2014-01-01

    A new modified Angelov current—voltage characteristic model equation is proposed to improve the drain—source current (I ds ) simulation of an AlGaN/GaN-based (gallium nitride) high electron mobility transistor (AlGaN/GaN-based HEMT) at high power operation. Since an accurate radio frequency (RF) current simulation is critical for a correct power simulation of the device, in this paper we propose a method of AlGaN/GaN high electron mobility transistor (HEMT) nonlinear large-signal model extraction with a supplemental modeling of RF drain—source current as a function of RF input power. The improved results of simulated output power, gain, and power added efficiency (PAE) at class-AB quiescent bias of V gs = −3.5 V, V ds = 30 V with a frequency of 9.6 GHz are presented. (condensed matter: electronic structure, electrical, magnetic, and optical properties)

  4. Orphan sources

    International Nuclear Information System (INIS)

    Pust, R.; Urbancik, L.

    2008-01-01

    The presentation describes how the stable detection systems (hereinafter referred to as S DS ) have contributed to reveal the uncontrolled sources of ionizing radiation on the territory of the State Office for Nuclear Safety (SONS) Brno Regional Centre (RC Brno). It also describes the emergencies which were solved by or in which the workers from the Brno. Regional Centre participated in. The contribution is divided into the following chapters: A. SDS systems installed on the territory of SONS RC Brno; B. Selected unusual emergencies; C. Comments to individual emergencies; D. Aspects of SDS operation in term of their users; E. Aspects of SDS operation and related activities in term of radiation protection; F. Current state of orphan sources. (authors)

  5. Footrot and interdigital dermatitis in sheep: farmer satisfaction with current management, their ideal management and sources used to adopt new strategies.

    Science.gov (United States)

    Wassink, G J; George, T R N; Kaler, J; Green, L E

    2010-08-01

    The aims of this research were to identify management practices that sheep farmers currently use to treat and prevent footrot in sheep and whether they consider that these are successful management tools and to find out how sheep farmers would ideally like to manage footrot in their flock. Over 90% of lameness in sheep in the UK is caused by Dichelobacter nodosus, which presents clinically as interdigital dermatitis (ID) alone or with separation of hoof horn (FR). A questionnaire was sent to 265 farmers to investigate their current management and their satisfaction with current management of the spectrum of clinical presentations of footrot. Farmers were also asked their ideal management of footrot and their interest in, and sources of information for, change. Approximately 160 farmers responded. Farmers satisfied with current management reported a prevalence of lameness 5%. These farmers practised routine foot trimming, footbathing and vaccination against footrot. Whilst 89% of farmers said they were satisfied with their management of FR over 34% were interested in changing management. Farmers identified veterinarians as the most influential source for new information. Farmers reported that ideally they would control FR by culling/isolating lame sheep, sourcing replacements from non-lame parents, trimming feet less, using antibacterial treatments less and using vaccination more. Footbathing was a commonly used management that was linked with dissatisfaction and that also was listed highly as an ideal management. Consequently, some of the ideal managements are in agreement with our understanding of disease control (culling and isolation, sourcing healthy replacements) but others are in contrast with our current knowledge of management and farmers self-reporting of satisfaction of management of footrot (less use of antibacterial treatment, more footbathing and vaccination). One explanation for this is the theory of cognitive dissonance where belief follows behaviour

  6. Assessing the Applicability of Currently Available Methods for Attributing Foodborne Disease to Sources, Including Food and Food Commodities

    DEFF Research Database (Denmark)

    Pires, Sara Monteiro

    2013-01-01

    on the public health question being addressed, on the data requirements, on advantages and limitations of the method, and on the data availability of the country or region in question. Previous articles have described available methods for source attribution, but have focused only on foodborne microbiological...

  7. Quantum nano ring composed of quantum dots as a source of pure persistent spin or charge current

    International Nuclear Information System (INIS)

    Eslami, L.; Faizabadi, E.; Ahmadi, S.

    2016-01-01

    Spin-dependent persistent current in a quantum ring constituted by two normal and one magnetic quantum dots, in the presence of Rashba spin–orbit interaction is studied by using Green function technique. It is shown that the presence of the magnetic quantum dot breaks the degeneracy of the density of states of electrons with different spin states. Besides, the Rashba spin–orbit interaction along with the magnetic quantum dot develops tunable persistent spin and charge currents. Moreover, the persistent charge current induces a fully adjustable magnetic flux whose direction and magnitude can be tuned by altering the strength of the Rashba spin–orbit interaction. - Highlights: • An array of normal and magnetic quantum dots with Rashba effect is studied. • Spin-dependent persistent current and DOS are studied using Green function method. • The magnetic quantum dot breaks degeneracy of DOS of up and down spin electrons. • The persistent spin and charge currents are tuned by adjusting the Rashba constant. • The persistent charge current induces tunable magnetic field at the center of ring.

  8. Reference-quality genome sequence of Aegilops tauschii, the source of wheat D genome, shows that recombination shapes genome structure and evolution

    Science.gov (United States)

    Aegilops tauschii is the diploid progenitor of the D genome of hexaploid wheat and an important genetic resource for wheat. A reference-quality sequence for the Ae. tauschii genome was produced with a combination of ordered-clone sequencing, whole-genome shotgun sequencing, and BioNano optical geno...

  9. Iodine frequency references for space

    International Nuclear Information System (INIS)

    Schuldt, Thilo; Braxmaier, Claus; Döringshoff, Klaus; Peters, Achim; Oswald, Markus; Johann, Ulrich

    2017-01-01

    Optical frequency references are a key element for the realization of future space missions. They are needed for missions related to tests of fundamental physics, gravitational wave detection, Earth observation and navigation and ranging. In missions such as GRACE follow-on or LISA the optical frequency reference is used as light source for high-sensitivity inter-satellite distance metrology. While cavity-based systems are current baseline e.g. for LISA, frequency stabilization on a hyperfine transition in molecular iodine near 532 nm is a promising alternative. Due to its absolute frequency, iodine standards crucially simplify the initial spacecraft acquisition procedures. Current setups fulfill the GRACE-FO and LISA frequency stability requirements and are realized near Engineering Model level. We present the current status of our developments on Elegant Breadboard (EBB) and Engineering Model (EM) level taking into account specific design criteria for space compatibility such as compactness (size iodine spectroscopy EM: 38 × 18 × 10 cm 3 ) and robustness. Both setups achieved similar frequency stabilities of ∼ 1 · 10 −14 at an integration time of 1 s and below 5 · 10 −15 at integration times between 10 s and 1000 s. Furthermore, we present an even more compact design currently developed for a sounding rocket mission with launch in 2017. (paper)

  10. Design of current source DC/DC converter and inverter for 2kW fuel cell application

    DEFF Research Database (Denmark)

    Andreiciks, A.; Steiks, I.; Krievs, O.

    2013-01-01

    In order to use hydrogen fuel cell in domestic applications either as main power supply or backup power source, the low DC output voltage of the fuel cell has to be matched to the voltage level and frequency of the utility grid AC voltage. The interfacing power converter systems usually consist...... system is designed for interfacing a 2kW proton exchange membrane (PEM) fuel cell....

  11. Computer code determination of tolerable accel current and voltage limits during startup of an 80 kV MFTF sustaining neutral beam source

    International Nuclear Information System (INIS)

    Mayhall, D.J.; Eckard, R.D.

    1979-01-01

    We have used a Lawrence Livermore Laboratory (LLL) version of the WOLF ion source extractor design computer code to determine tolerable accel current and voltage limits during startup of a prototype 80 kV Mirror Fusion Test Facility (MFTF) sustaining neutral beam source. Arc current limits are also estimated. The source extractor has gaps of 0.236, 0.721, and 0.155 cm. The effective ion mass is 2.77 AMU. The measured optimum accel current density is 0.266 A/cm 2 . The gradient grid electrode runs at 5/6 V/sub a/ (accel voltage). The suppressor electrode voltage is zero for V/sub a/ < 3 kV and -3 kV for V/sub a/ greater than or equal to 3 kV. The accel current density for optimum beam divergence is obtained for 1 less than or equal to V/sub a/ less than or equal to 80 kV, as are the beam divergence and emittance

  12. Estimating urban forest carbon sequestration potential in the southern United States using current remote sensing imagery sources

    Science.gov (United States)

    Krista Merry; Pete Bettinger; Jacek Siry; J. Michael Bowker

    2015-01-01

    With an increased interest in reducing carbon dioxide in the atmosphere, tree planting and maintenance in urban areas has become a viable option for increasing carbon sequestration. Methods for assessing the potential for planting trees within an urban area should allow for quick, inexpensive, and accurate estimations of available land using current remote sensing...

  13. "Professional Helper" or "Helping Professional?" The Patient-Physician Relationship in the Chronic Pain Setting, With Special Reference to the Current Opioid Debate.

    Science.gov (United States)

    Bäckryd, Emmanuel

    2016-01-01

    There seems to be a strong cultural expectation among patients for effective pain relief. As a result, physicians often find themselves trying to bridge the gap between the chronic pain patient's expectations and harsh biomedical reality. The typology of Emanuel and Emanuel of four models for the patient-physician relationship is used in this article as a conceptual tool to examine the possible roles of physicians in the context of chronic noncancer pain. Their typology is reconceptualized as a "pathway" along which the physician is able to walk more or less far, starting from the "information" end of the path. The other end of the pathway is "caring deliberation." I then propose that, in pain medicine today, consumerism is a powerful incentive for physicians to stay at the information end of the spectrum. Against this background, I discuss the current opioid epidemic in the United States and the need for what has been called a new medical professionalism. I conclude by challenging educators involved in pain medicine continuing professional development to not only design adequate biomedical-educational programs, but also consider issues like professionalism, personal development, critical self-reflection, and the ethics of engaging in caring deliberation with chronic pain patients.

  14. Management of inflammatory bowel disease-related anemia and iron deficiency with specific reference to the role of intravenous iron in current practice.

    Science.gov (United States)

    Stein, Jürgen; Aksan, Ayşegül; Farrag, Karima; Dignass, Axel; Radeke, Heinfried H

    2017-11-01

    Anemia is a common extraintestinal manifestation in patients with inflammatory bowel disease, impacting disease prognosis, morbidity, hospitalization rates and time lost from work. While iron deficiency anemia and anemia of chronic inflammation predominate, combinations of hematimetric and biochemical markers facilitate the diagnosis and targeted therapy of other etiologies according to their underlying pathophysiological causes. Intravenous iron replacement is currently recommended in IBD patients with moderate to severe anemia or intolerance to oral iron. Areas covered: This review examines the impact, pathophysiology and diagnostics of iron deficiency and anemia, compares the characteristics and safety profiles of available oral and intravenous iron preparations, and highlights issues which require consideration in decision making for therapy administration and monitoring. Expert opinion: Modern intravenous iron formulations have been shown to be safe and effective in IBD patients, allowing rapid anemia correction and repletion of iron stores. While traditional oral iron preparations are associated with increased inflammation, negative effects on the microbiome, and poor tolerance and compliance, first clinical trial data indicate that newer oral compounds such as ferric maltol and sucrosomial iron offer improved tolerability and may thus offer a viable alternative for the future.

  15. On the energy dependence of the relative contributions ionospheric and solar sources of the ring current protons

    International Nuclear Information System (INIS)

    Kovtyukh, A.

    2007-01-01

    The energy dependence of a fraction of ring current protons of i onospheric origin is calculated using the AMPTE/CCE data for a typical magnetic storm (D st = -120 nT). It is shown that at L = 6-7 (L is the Mcllwain parameter) this fraction monotonically decreases from ∼83 to 25-30% with an increase in proton energy from 5 to 315 keV and is 30-40% at energy 40-50 keV corresponding to the maximum of proton energy density at L 6-7. It is evident that the core of the ring current (L = 3.7-4.7) is enriched by solar protons with E∼10-200 keV during storm main phase (the maximum effect is achieved at E∼20-50 keV). (author)

  16. Handbook of reference electrodes

    CERN Document Server

    Inzelt, György; Scholz, Fritz

    2013-01-01

    Reference Electrodes are a crucial part of any electrochemical system, yet an up-to-date and comprehensive handbook is long overdue. Here, an experienced team of electrochemists provides an in-depth source of information and data for the proper choice and construction of reference electrodes. This includes all kinds of applications such as aqueous and non-aqueous solutions, ionic liquids, glass melts, solid electrolyte systems, and membrane electrodes. Advanced technologies such as miniaturized, conducting-polymer-based, screen-printed or disposable reference electrodes are also covered. Essen

  17. R quick syntax reference

    CERN Document Server

    Tollefson, Margot

    2014-01-01

    The R Quick Syntax Reference is a handy reference book detailing the intricacies of the R language. Not only is R a free, open-source tool, R is powerful, flexible, and has state of the art statistical techniques available. With the many details which must be correct when using any language, however, the R Quick Syntax Reference makes using R easier.Starting with the basic structure of R, the book takes you on a journey through the terminology used in R and the syntax required to make R work. You will find looking up the correct form for an expression quick and easy. With a copy of the R Quick

  18. Analytical Subthreshold Current and Subthreshold Swing Models for a Fully Depleted (FD) Recessed-Source/Drain (Re-S/D) SOI MOSFET with Back-Gate Control

    Science.gov (United States)

    Saramekala, Gopi Krishna; Tiwari, Pramod Kumar

    2017-08-01

    Two-dimensional (2D) analytical models for the subthreshold current and subthreshold swing of the back-gated fully depleted recessed-source/drain (Re-S/D) silicon-on-insulator (SOI) metal-oxide-semiconductor field-effect transistor (MOSFET) are presented. The surface potential is determined by solving the 2D Poisson equation in both channel and buried-oxide (BOX) regions, considering suitable boundary conditions. To derive closed-form expressions for the subthreshold characteristics, the virtual cathode potential expression has been derived in terms of the minimum of the front and back surface potentials. The effect of various device parameters such as gate oxide and Si film thicknesses, thickness of source/drain penetration into BOX, applied back-gate bias voltage, etc. on the subthreshold current and subthreshold swing has been analyzed. The validity of the proposed models is established using the Silvaco ATLAS™ 2D device simulator.

  19. Phytochemical Properties and Nutrigenomic Implications of Yacon as a Potential Source of Prebiotic: Current Evidence and Future Directions

    Directory of Open Access Journals (Sweden)

    Yang Cao

    2018-04-01

    Full Text Available The human gut is densely populated with diverse microbial communities that are essential to health. Prebiotics and fiber have been shown to possess the ability to modulate the gut microbiota. One of the plants being considered as a potential source of prebiotic is yacon. Yacon is an underutilized plant consumed as a traditional root-based fruit in South America. Yacon mainly contains fructooligosaccharides (FOS and inulin. Therefore, it has bifidogenic benefits for gut health, because FOS are not easily broken down by digestive enzymes. Bioactive chemical compounds and extracts isolated from yacon have been studied for their various nutrigenomic properties, including as a prebiotic for intestinal health and their antimicrobial and antioxidant effects. This article reviewed scientific studies regarding the bioactive chemical compounds and nutrigenomic properties of extracts and isolated compounds from yacon. These findings may help in further research to investigate yacon-based nutritional products. Yacon can be considered a potential prebiotic source and a novel functional food. However, more detailed epidemiological, animal, and human clinical studies, particularly mechanism-based and phytopharmacological studies, are lacking for the development of evidence-based functional food products.

  20. Phytochemical Properties and Nutrigenomic Implications of Yacon as a Potential Source of Prebiotic: Current Evidence and Future Directions

    Science.gov (United States)

    Cao, Yang; Zhang, Hongxia; Jin, Yifan; Zhang, Yihe; Hayford, Frank

    2018-01-01

    The human gut is densely populated with diverse microbial communities that are essential to health. Prebiotics and fiber have been shown to possess the ability to modulate the gut microbiota. One of the plants being considered as a potential source of prebiotic is yacon. Yacon is an underutilized plant consumed as a traditional root-based fruit in South America. Yacon mainly contains fructooligosaccharides (FOS) and inulin. Therefore, it has bifidogenic benefits for gut health, because FOS are not easily broken down by digestive enzymes. Bioactive chemical compounds and extracts isolated from yacon have been studied for their various nutrigenomic properties, including as a prebiotic for intestinal health and their antimicrobial and antioxidant effects. This article reviewed scientific studies regarding the bioactive chemical compounds and nutrigenomic properties of extracts and isolated compounds from yacon. These findings may help in further research to investigate yacon-based nutritional products. Yacon can be considered a potential prebiotic source and a novel functional food. However, more detailed epidemiological, animal, and human clinical studies, particularly mechanism-based and phytopharmacological studies, are lacking for the development of evidence-based functional food products. PMID:29649123

  1. Phytochemical Properties and Nutrigenomic Implications of Yacon as a Potential Source of Prebiotic: Current Evidence and Future Directions.

    Science.gov (United States)

    Cao, Yang; Ma, Zheng Feei; Zhang, Hongxia; Jin, Yifan; Zhang, Yihe; Hayford, Frank

    2018-04-12

    The human gut is densely populated with diverse microbial communities that are essential to health. Prebiotics and fiber have been shown to possess the ability to modulate the gut microbiota. One of the plants being considered as a potential source of prebiotic is yacon. Yacon is an underutilized plant consumed as a traditional root-based fruit in South America. Yacon mainly contains fructooligosaccharides (FOS) and inulin. Therefore, it has bifidogenic benefits for gut health, because FOS are not easily broken down by digestive enzymes. Bioactive chemical compounds and extracts isolated from yacon have been studied for their various nutrigenomic properties, including as a prebiotic for intestinal health and their antimicrobial and antioxidant effects. This article reviewed scientific studies regarding the bioactive chemical compounds and nutrigenomic properties of extracts and isolated compounds from yacon. These findings may help in further research to investigate yacon-based nutritional products. Yacon can be considered a potential prebiotic source and a novel functional food. However, more detailed epidemiological, animal, and human clinical studies, particularly mechanism-based and phytopharmacological studies, are lacking for the development of evidence-based functional food products.

  2. An Optimal PR Control Strategy with Load Current Observer for a Three-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2015-07-01

    Full Text Available Inverter voltage control is an important task in the operation of a DC/AC microgrid system. To improve the inverter voltage control dynamics, traditional approaches attempt to measure and feedforward the load current, which, however, needs remote measurement with communications in a microgrid system with distributed loads. In this paper, a load current observer (LCO based control strategy, which does not need remote measurement, is proposed for sinusoidal signals tracking control of a three-phase inverter of the microgrid. With LCO, the load current is estimated precisely, acting as the feedforward of the dual-loop control, which can effectively enlarge the stability margin of the control system and improve the dynamic response to load disturbance. Furthermore, multiple PR regulators are applied in this strategy conducted in a stationary  frame to suppress the transient fluctuations and the total harmonic distortion (THD of the output voltage and achieve faster transient performance compared with traditional dual-loop control in a rotating dq0 frame under instantaneous change of various types of load (i.e., balanced load, unbalanced load, and nonlinear load. The parameters of multiple PR regulators are analyzed and selected through the root locus method and the stability of the whole control system is evaluated and analyzed. Finally, the validity of the proposed approach is verified through simulations and a three-phase prototype test system with a TMS320F28335 DSP.

  3. Effect of high energy electrons on H{sup −} production and destruction in a high current DC negative ion source for cyclotron

    Energy Technology Data Exchange (ETDEWEB)

    Onai, M., E-mail: onai@ppl.appi.keio.ac.jp; Fujita, S.; Hatayama, A. [Faculty of Science and Technology, Keio University, Yokohama 223-8522 (Japan); Etoh, H.; Aoki, Y. [Sumitomo Heavy Industries, Ltd., Tokyo 141-6025 (Japan); Shibata, T. [High Energy Accelerator Research Organization (KEK), Ibaraki (Japan); Mattei, S.; Lettry, J. [CERN Rte de Meyrin, 1200 Geneva (Switzerland)

    2016-02-15

    Recently, a filament driven multi-cusp negative ion source has been developed for proton cyclotrons in medical applications. In this study, numerical modeling of the filament arc-discharge source plasma has been done with kinetic modeling of electrons in the ion source plasmas by the multi-cusp arc-discharge code and zero dimensional rate equations for hydrogen molecules and negative ions. In this paper, main focus is placed on the effects of the arc-discharge power on the electron energy distribution function and the resultant H{sup −} production. The modelling results reasonably explains the dependence of the H{sup −} extraction current on the arc-discharge power in the experiments.

  4. Current and future trends in fecal source tracking and deployment in the Lake Taihu Region of China

    Science.gov (United States)

    Hagedorn, Charles; Liang, Xinqiang

    The emerging discipline of microbial and/or chemical source tracking (collectively termed fecal source tracking (FST)) is being used to identify origins of fecal contamination in polluted waters in many countries around the world. FST has developed rapidly because standard methods of measuring contamination in water by enumerating fecal indicator bacteria (FIB) such as fecal coliforms and enterococci do not identify the sources of the contamination. FST is an active area of research and development in both the academic and private sectors and includes: Developing and testing new microbial and chemical FST methods. Determining the geographic application and animal host ranges of existing and emerging FST techniques. Conducting experimental comparisons of FST techniques. Combining direct monitoring of human pathogens associated with waterborne outbreaks and zoonotic pathogens responsible for infections among people, wildlife, or domesticated animals with the use of FST techniques. Applying FST to watershed analysis and coastal environments. Designing appropriate statistical and probability analysis of FST data and developing models for mass loadings of host-specific fecal contamination. This paper includes a critical review of FST with emphasis on the extent to which methods have been tested (especially in comparison with other methods and/or with blind samples), which methods are applicable to different situations, their shortcomings, and their usefulness in predicting public health risk or pathogen occurrence. In addition, the paper addresses the broader question of whether FST and fecal indicator monitoring is the best approach to regulate water quality and protect human health. Many FST methods have only been tested against sewage or fecal samples or isolates in laboratory studies (proof of concept testing) and/or applied in field studies where the “real” answer is not known, so their comparative performance and accuracy cannot be assessed. For FST to be

  5. Effect of Sertraline on Current-Source Distribution of the High Beta Frequency Band: Analysis of Electroencephalography under Audiovisual Erotic Stimuli in Healthy, Right-Handed Males.

    Science.gov (United States)

    Lee, Seung Hyun; Hyun, Jae Seog; Kwon, Oh-Young

    2010-08-01

    The purpose of this study was to examine the cerebral changes in high beta frequency oscillations (22-30 Hz) induced by sertraline and by audiovisual erotic stimuli in healthy adult males. Scalp electroencephalographies (EEGs) were conducted twice in 11 healthy, right-handed males, once before sertraline intake and again 4 hours thereafter. The EEGs included four sessions recorded sequentially while the subjects were resting, watching a music video, resting, and watching an erotic video for 3 minutes, 5 minutes, 3 minutes, and 5 minutes, respectively. We performed frequency-domain analysis using the EEGs with a distributed model of current-source analysis. The statistical nonparametric maps were obtained from the sessions of watching erotic and music videos (perotic stimuli decreased the current-source density of the high beta frequency band in the middle frontal gyrus, the precentral gyrus, the postcentral gyrus, and the supramarginal gyrus of the left cerebral hemisphere in the baseline EEGs taken before sertraline intake (perotic stimuli did not induce any changes in current-source distribution of the brain 4 hours after sertraline intake. It is speculated that erotic stimuli may decrease the function of the middle frontal gyrus, the precentral gyrus, the postcentral gyrus, and the supramarginal gyrus of the left cerebral hemisphere in healthy adult males. This change may debase the inhibitory control of the brain against erotic stimuli. Sertraline may reduce the decrement in inhibitory control.

  6. Analytical and semi-analytical formalism for the voltage and the current sources of a superconducting cavity under dynamic detuning

    CERN Document Server

    Doleans, M

    2003-01-01

    Elliptical superconducting radio frequency (SRF) cavities are sensitive to frequency detuning because they have a high Q value in comparison with normal conducting cavities and weak mechanical properties. Radiation pressure on the cavity walls, microphonics, and tuning system are possible sources of dynamic detuning during SRF cavity-pulsed operation. A general analytic relation between the cavity voltage, the dynamic detuning function, and the RF control function is developed. This expression for the voltage envelope in a cavity under dynamic detuning and dynamic RF controls is analytically expressed through an integral formulation. A semi-analytical scheme is derived to calculate the voltage behavior in any practical case. Examples of voltage envelope behavior for different cases of dynamic detuning and RF control functions are shown. The RF control function for a cavity under dynamic detuning is also investigated and as an application various filling schemes are presented.

  7. New strategy for eliminating zero-sequence circulating current between parallel operating three-level NPC voltage source inverters

    DEFF Research Database (Denmark)

    Li, Kai; Dong, Zhenhua; Wang, Xiaodong

    2018-01-01

    buses, that are operating in parallel. First, an equivalent model of ZSCC in a three-phase three-level NPC inverter paralleled system is developed. Second, on the basis of the analysis of the excitation source of ZSCCs, i.e., the difference in common mode voltages (CMVs) between paralleled inverters......, the ZCMV-PWM method is presented to reduce CMVs, and a simple electric circuit is adopted to control ZSCCs and neutral point potential. Finally, simulation and experiment are conducted to illustrate effectiveness of the proposed strategy. Results show that ZSCCs between paralleled inverters can...... be eliminated effectively under steady and dynamic states. Moreover, the proposed strategy exhibits the advantage of not requiring carrier synchronization. It can be utilized in inverters with different types of filter....

  8. Chlorinated volatile organic compounds (Cl-VOCs) in environment - sources, potential human health impacts, and current remediation technologies.

    Science.gov (United States)

    Huang, Binbin; Lei, Chao; Wei, Chaohai; Zeng, Guangming

    2014-10-01

    Chlorinated volatile organic compounds (Cl-VOCs), including polychloromethanes, polychloroethanes and polychloroethylenes, are widely used as solvents, degreasing agents and a variety of commercial products. These compounds belong to a group of ubiquitous contaminants that can be found in contaminated soil, air and any kind of fluvial mediums such as groundwater, rivers and lakes. This review presents a summary of the research concerning the production levels and sources of Cl-VOCs, their potential impacts on human health as well as state-of-the-art remediation technologies. Important sources of Cl-VOCs principally include the emissions from industrial processes, the consumption of Cl-VOC-containing products, the disinfection process, as well as improper storage and disposal methods. Human exposure to Cl-VOCs can occur through different routes, including ingestion, inhalation and dermal contact. The toxicological impacts of these compounds have been carefully assessed, and the results demonstrate the potential associations of cancer incidence with exposure to Cl-VOCs. Most Cl-VOCs thus have been listed as priority pollutants by the Ministry of Environmental Protection (MEP) of China, Environmental Protection Agency of the U.S. (U.S. EPA) and European Commission (EC), and are under close monitor and strict control. Yet, more efforts will be put into the epidemiological studies for the risk of human exposure to Cl-VOCs and the exposure level measurements in contaminated sites in the future. State-of-the-art remediation technologies for Cl-VOCs employ non-destructive methods and destructive methods (e.g. thermal incineration, phytoremediation, biodegradation, advanced oxidation processes (AOPs) and reductive dechlorination), whose advantages, drawbacks and future developments are thoroughly discussed in the later sections. Copyright © 2014 Elsevier Ltd. All rights reserved.

  9. Development of a “Current Energy Mix Scenario” and a “Electricity as Main Energy Source Scenario” for electricity demand up to 2100

    Directory of Open Access Journals (Sweden)

    Mário J. S. Brito

    2014-06-01

    Full Text Available In this work, we develop a model to forecast world electricity production up to 2100. We analyze historical data for electricity production, population and GDP per Capita for the period 1900–2008. We show that electricity production follows general trends. First, there is an electricity intensity target of 0.20-0.25 kWh per unit of GDP (US$2012 as economies mature, except in countries traditionally relying heavily on renewable electricity (hydroelectricity, for whom this target ranges between 0.50 to 0.80 kWh per unit GDP. Also, countries that belong to the same region tend to follow the evolution of electricity production and GDP/Capita of a regional “modelcountry”. Equations that describe the behavior of these model countries are used to forecast electricity production per capita up to 2100 under a low and a high scenario for the evolution of GDP per Capita. For electricity production two main scenarios were set: “Current Energy MixScenario” and “Electricity as Main Energy Source Scenario”, with two additional sub scenarios considering slightly different electric intensities. Forecasts up to 2100 yield a demand forelectricity production 3.5 to 5 times higher than the current production for the “Current EnergyMix Scenario” and about 9 to 14 times for the “Electricity as Main Energy Source Scenario”. Forecasts for the “Current Energy Mix Scenario” matched well with forecasts from IEA/EIA (International Energy Agency/ Energy Information Administration while the forecasts for the“Electricity as the Main Energy Source Scenario” are much higher than current predictions.

  10. Pre-earthquake signals – Part I: Deviatoric stresses turn rocks into a source of electric currents

    Directory of Open Access Journals (Sweden)

    F. T. Freund

    2007-09-01

    Full Text Available Earthquakes are feared because they often strike so suddenly. Yet, there are innumerable reports of pre-earthquake signals. Widespread disagreement exists in the geoscience community how these signals can be generated in the Earth's crust and whether they are early warning signs, related to the build-up of tectonic stresses before major seismic events. Progress in understanding and eventually using these signals has been slow because the underlying physical process or processes are basically not understood. This has changed with the discovery that, when igneous or high-grade metamorphic rocks are subjected to deviatoric stress, dormant electronic charge carriers are activated: electrons and defect electrons. The activation increases the number density of mobile charge carriers in the rocks and, hence, their electric conductivity. The defect electrons are associated with the oxygen anion sublattice and are known as positive holes or pholes for short. The boundary between stressed and unstressed rock acts a potential barrier that lets pholes pass but blocks electrons. Therefore, like electrons and ions in an electrochemical battery, the stress-activated electrons and pholes in the "rock battery" have to flow out in different directions. When the circuit is closed, the battery currents can flow. The discovery of such stress-activated currents in crustal rocks has far-reaching implications for understanding pre-earthquake signals.

  11. First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference

    Energy Technology Data Exchange (ETDEWEB)

    Diekhoff, Torsten; Kiefer, Tobias; Hamm, Bernd; Hermann, Kay-Geert A. [Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Department of Radiology, Berlin (Germany); Ziegeler, Katharina; Feist, Eugen [Charite - Universitaetsmedizin Berlin Campus Mitte, Humboldt-Universitaet zu Berlin, Freie Universitaet Berlin, Department of Rheumatology and Clinical Immunology, Berlin (Germany); Mews, Juergen [Toshiba Medical Systems Europe, BV, Zoetermeer (Netherlands)

    2015-11-15

    Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future. (orig.)

  12. First experience with single-source dual-energy computed tomography in six patients with acute arthralgia: a feasibility experiment using joint aspiration as a reference

    International Nuclear Information System (INIS)

    Diekhoff, Torsten; Kiefer, Tobias; Hamm, Bernd; Hermann, Kay-Geert A.; Ziegeler, Katharina; Feist, Eugen; Mews, Juergen

    2015-01-01

    Dual-energy computed tomography (DECT) is an emerging imaging technique for examining patients with suspected gout. Single-source dual-energy CT (S-DECT) is a new way of obtaining DECT information on conventional CT scanners rather than using special dual-source CT systems. We tested the feasibility of S-DECT (320-row CT; Aquilion ONE, Toshiba Medical Systems, Otawara, Japan) in 6 patients (5 men, 1 woman; mean age 61.3, range 48 to 69 years) with acute arthralgia and suspected gout, and compared the S-DECT findings with the results of joint aspiration. Three patients had a diagnosis of gouty arthritis with negatively birefringent crystals in synovial fluid, in addition to gouty tophi in S-DECT. Three patients had no detectable crystals by polarization microscopy and no tophi on DECT. Their final diagnoses were rheumatoid arthritis, activated osteoarthritis, and septic arthritis in one case each. This initial experience suggests that S-DECT might be a valuable alternative to dual-source CT. Hence, more patients may benefit from its additional diagnostic abilities in the future. (orig.)

  13. U.S. Department Of Energy's nuclear engineering education research: highlights of recent and current research-I. 6. Radioisotope Power Sources for MEMS Devices

    International Nuclear Information System (INIS)

    Blanchard, James P.

    2001-01-01

    Micro-electromechanical systems (MEMS) comprise a rapidly expanding research field with potential applications varying from sensors in airbags to more recent optical applications. Depending on the application, these devices often require an onboard power source for remote operation, especially in cases requiring operation for an extended period of time. Previously suggested power sources include fossil fuels and solar energy, but nuclear power sources may provide significant advantages for certain applications. Hence, the objective of this study is to establish the viability of using radioisotopes to power realistic MEMS devices. Four methods of incorporating radioactive material into the MEMS devices have been studied. These are (a) use of an external, solid source; (b) use of a liquid source; (c) plating of the source into a prefabricated device; and (d) incorporation of microspheres containing tritium. In approach (c), electro-less plating is used to deposit 63 Ni into an MEMS device. A standard recipe for electro-less plating of nickel is used. In approach (d), we obtained glass microspheres that contain 6 Li and irradiated them in the University of Wisconsin Nuclear Reactor to produce tritium. Using this procedure, we can produce activities of up to 12.8 mCi/g for each hour of irradiation. Our first battery incorporates a liquid 63 Ni source into a micro-machined pn-junction battery. The initial design has 13 micro-machined channels in a silicon substrate. The channels are employed to hold the liquid source and to increase the surface area, which is important because the current generated by the battery is proportional to the junction area. To measure the performance of our three-dimensional pn-junction in the presence of a radioactive source, we placed 8 μl (64 μCi) of liquid source inside the channels and then covered it with a black box to shield it from the light. Figure 1 displays the I-V curves for this battery measured at 30 min, 2 h, and 16 h after

  14. Development of a low-energy and high-current pulsed neutral beam injector with a washer-gun plasma source for high-beta plasma experiments.

    Science.gov (United States)

    Ii, Toru; Gi, Keii; Umezawa, Toshiyuki; Asai, Tomohiko; Inomoto, Michiaki; Ono, Yasushi

    2012-08-01

    We have developed a novel and economical neutral-beam injection system by employing a washer-gun plasma source. It provides a low-cost and maintenance-free ion beam, thus eliminating the need for the filaments and water-cooling systems employed conventionally. In our primary experiments, the washer gun produced a source plasma with an electron temperature of approximately 5 eV and an electron density of 5 × 10(17) m(-3), i.e., conditions suitable for ion-beam extraction. The dependence of the extracted beam current on the acceleration voltage is consistent with space-charge current limitation, because the observed current density is almost proportional to the 3/2 power of the acceleration voltage below approximately 8 kV. By optimizing plasma formation, we successfully achieved beam extraction of up to 40 A at 15 kV and a pulse length in excess of 0.25 ms. Its low-voltage and high-current pulsed-beam properties enable us to apply this high-power neutral beam injection into a high-beta compact torus plasma characterized by a low magnetic field.

  15. REDISCOVERING MISES-HAYEK MONETARY AND BUSINESS CYCLE THEORY IN LIGHT OF THE CURRENT CRISIS: CREDIT EXPANSION AS A SOURCE OF ECONOMIC BOOM AND BUST

    Directory of Open Access Journals (Sweden)

    Marcin Mrowiec

    2013-10-01

    Full Text Available The article starts with a brief description of Mises’ monetary theory, with emphasis on the Misesian differentiation of two kinds of credit: commodity and circulation credit, and with the description of the impact of circulation credit expansion on the business cycle. Further on it is described how Mises’ insights constituted the kernel of Austrian Business Cycle Theory, and how the same observations on the nature of credit constituted the kernel of the Chicago Plan (though Mises’ views on the nature of credit led him to different conculsions than it led the authors of the Chicago Plan, and how this plan is being “rediscovered” now. The following sections deal with observations of one of the preeminent current macroeconomic researches, Mr. Claudio Borio, on the elasticity of credit as the source of the current crisis, and on the importance of the financial cycle in analysing the current economic crisis. The author of this text demonstrates that Austrian Business Cycle Theory gave the same answer regarding the sources of economic crises that now modern macroeconomic theory seems to be approaching, and that the postulates for successful financial cycle modeling are already included in the ABCT. Finally, some observations on the current crisis, as well as proposals of avenues of further research are proposed.

  16. High-current and low acceleration voltage arsenic ion implanted polysilicon-gate and source-drain electrode Si mos transistor

    International Nuclear Information System (INIS)

    Saito, Yasuyuki; Sugimura, Yoshiro; Sugihara, Michiyuki

    1993-01-01

    The fabrication process of high current arsenic (As) ion implanted polysilicon (Si) gate and source drain (SD) electrode Si n-channel metal oxide-semiconductor field effect transistor (MOSFET) was examined. Poly Si film n-type doping was performed by using high current (typical current: 2mA) and relatively low acceleration voltage (40keV) As ion implantation technique (Lintott series 3). It was observed that high dose As implanted poly Si films as is show refractoriness against radical fluorine excited by microwave. Using GCA MANN4800 (m/c ID No.2, resist: OFPR) mask pattern printing technique, the high current As ion implantation technique and radical fluorine gas phase etching (Chemical dry etching: CDE) technique, the n-channel Poly Si gate (ρs = ≅100Ω/□) enhancement MQSFETs(ρs source drain = ≅50Ω/□, SiO 2 gate=380 angstrom) with off-leak-less were obtained on 3 inch Czochralski grown 2Ωcm boron doped p type wafers (Osaka titanium). By the same process, a 8 bit single chip μ-processor with 26MHz full operation was performed

  17. Study on pulsed-discharge devices with high current rising rate for point spot short-wavelength source in dense plasma observations

    International Nuclear Information System (INIS)

    Tachinami, Fumitaka; Anzai, Nobuyuki; Sasaki, Toru; Kikuchi, Takashi; Harada, Nob.

    2014-01-01

    A pulsed-power generator with high current rise based on a pulse-forming-network was studied toward generating intense point-spot X-ray source. To obtain the high rate of current rise, we have designed the compact discharge device with low circuit inductance. The results indicate that the inductance of the compact discharge device was dominated by a gap switch inductance. To reduce the gap switch inductance and operation voltage, the feasible gap switch inductance in the vacuum chamber has been estimated by the circuit simulation. The gap switch inductance can be reduced by the lower pressure operation. It means that the designed discharge device achieves the rate of current rise of 10 12 A/s

  18. High-performance control of a three-phase voltage-source converter including feedforward compensation of the estimated load current

    International Nuclear Information System (INIS)

    Leon, Andres E.; Solsona, Jorge A.; Busada, Claudio; Chiacchiarini, Hector; Valla, Maria Ines

    2009-01-01

    In this paper a new control strategy for voltage-source converters (VSC) is introduced. The proposed strategy consists of a nonlinear feedback controller based on feedback linearization plus a feedforward compensation of the estimated load current. In our proposal an energy function and the direct-axis current are considered as outputs, in order to avoid the internal dynamics. In this way, a full linearization is obtained via nonlinear transformation and feedback. An estimate of the load current is feedforwarded to improve the performance of the whole system and to diminish the capacitor size. This estimation allows to obtain a more rugged and cheaper implementation. The estimate is calculated by using a nonlinear reduced-order observer. The proposal is validated through different tests. These tests include performance in presence of switching frequency, measurement filters delays, parameters uncertainties and disturbances in the input voltage.

  19. Recent trends and current practices for secondary processing of zinc and lead. Part II: zinc recovery from secondary sources.

    Science.gov (United States)

    Sahu, Kamala Kanta; Agrawal, Archana; Pandey, Banshi Dhar

    2004-08-01

    Almost all metallurgical processes are associated with the generation of wastes and residues that may be hazardous or non-hazardous in nature depending upon the criteria specified by institutions such as the US Environment Protection Agency, etc. Wastes containing heavy and toxic metals such as arsenic, cadmium, chromium, nickel, lead, copper, mercury, zinc, etc., that are present beyond permissible limits deemed to be treated or disposed of, and non-hazardous wastes can be utilized for metal recovery or safe disposal. Zinc is in growing demand all over the world. In India, a major amount of zinc is imported and therefore processing of zinc secondaries will assist in satisfying the gap between demand and supply to some extent. This report mainly focuses on the current practices and recent trends on the secondary processing of zinc. Attempts made by various laboratories to develop ecofriendly processes for the recovery of zinc from secondary raw materials are also described and discussed.

  20. Risk Assessment for Current and Projected Uses of Source Material Under a U.S. NRC General License and Exemption Request

    International Nuclear Information System (INIS)

    Smith, Michael A.; Napier, Bruce A.; Strom, Daniel J.; Short, Steven M.; Beatty, Cassandra V.; Stoker, Natasha F.; Newman, Teridee

    2006-01-01

    Source material is used under specific license, general license, and various exemptions from licensing requirements in 10 CFR Part 40. Because the Atomic Energy Act of 1946 focused on source material primarily in terms of its significance to the production of special nuclear material, the initial regulation of source material did not, apparently, give much emphasis to public health and safety. This emphasis on the production of special nuclear material continued in later modifications to the regulations. Because the last major update of these regulations was over 40 years ago (1961), the NRC is concerned that the current regulations for source materials may not be consistent with current health and safety regulations. Current industrial trends indicate a general decline in the use of thorium and uranium. Thorium was traditionally used in ceramics for refractory purposes but now is primarily used in scientific research, in a few electrical applications, as a chemical catalyst, and in optical lenses. Uranium, once popular in pigments and glazes, is now almost entirely limited to military applications that require special licensure and in scientific research. Due to high-disposal costs, increasingly stringent regulations, and public concerns related to the natural radioactivity of source material, industry is rapidly developing substitutes and alternate processes that do not involve the use of uranium and thorium. For these reasons, the downward trend in the use of source material is expected to continue. Researchers at Pacific Northwest National Laboratory (PNNL) identified how source materials meeting the exemption and general license requirements of 10 CFR 40.13(a), 40.13(b), and 40.22 are currently being used in industry and by the public. Based on the results of an extensive literature and internet search, few ?truly? new uses of source material were discovered that were not already considered in or represented by previous NRC analyses. Exceptions were (1) the

  1. Quantitative EEG and Current Source Density Analysis of Combined Antiepileptic Drugs and Dopaminergic Agents in Genetic Epilepsy: Two Case Studies.

    Science.gov (United States)

    Emory, Hamlin; Wells, Christopher; Mizrahi, Neptune

    2015-07-01

    Two adolescent females with absence epilepsy were classified, one as attention deficit and the other as bipolar disorder. Physical and cognitive exams identified hypotension, bradycardia, and cognitive dysfunction. Their initial electroencephalograms (EEGs) were considered slightly slow, but within normal limits. Quantitative EEG (QEEG) data included relative theta excess and low alpha mean frequencies. A combined treatment of antiepileptic drugs with a catecholamine agonist/reuptake inhibitor was sequentially used. Both patients' physical and cognitive functions improved and they have remained seizure free. The clinical outcomes were correlated with statistically significant changes in QEEG measures toward normal Z-scores in both anterior and posterior regions. In addition, low resolution electromagnetic tomography (LORETA) Z-scored source correlation analyses of the initial and treated QEEG data showed normalized patterns, supporting a neuroanatomic resolution. This study presents preliminary evidence for a neurophysiologic approach to patients with absence epilepsy and comorbid disorders and may provide a method for further research. © EEG and Clinical Neuroscience Society (ECNS) 2014.

  2. On the NBI system for substantial current drive in a fusion power plant: Status and R and D needs for ion source and laser neutralizer

    International Nuclear Information System (INIS)

    Franzen, P.; Fantz, U.

    2014-01-01

    Highlights: • NBI is a candidate for a cw tokamak DEMO due to its high current drive efficiency. • The plug-in efficiency must be improved from the present 20–30% to more than 50%. • A suitable candidate is a photo neutralizer with almost 100% neutralization efficiency; basic feasibility studies are underway. • Cw operation with a large availability puts rather high demands on source operation with some safety margins, especially for the components with high power density loads (source back plate and extraction system). • Alternatives to the present use of cesium are under exploitations. - Abstract: The requirements for the heating and current drive systems of a fusion power plant will strongly depend on the DEMO scenario. The paper discusses the R and D needs for a neutral beam injection system — being a candidate due to the highest current drive efficiency — for the most demanding scenario, a steady state tokamak DEMO. Most important issues are the improvement of the wall-plug efficiency from the present ∼25% to the required 50–60% by improving the neutralization efficiency with a laser neutralizer system and the improvement of the reliability of the ion source operation. The demands on and the potential of decreasing the ion source operation pressure, as well as decreasing the amount of co-extracted electrons and backstreaming ions are discussed using the ITER requirements and solutions as basis. A further concern is the necessity of cesium for which either the cesium management must be improved or alternatives to cesium for the production of negative ions have to be identified

  3. Transport of ions in presence of induced electric field and electrostatic turbulence - Source of ions injected into ring current

    Science.gov (United States)

    Cladis, J. B.; Francis, W. E.

    1985-01-01

    The transport of ions from the polar ionosphere to the inner magnetosphere during stormtime conditions has been computed using a Monte Carlo diffusion code. The effect of the electrostatic turbulence assumed to be present during the substorm expansion phase was simulated by a process that accelerated the ions stochastically perpendicular to the magnetic field with a diffusion coefficient proportional to the energization rate of the ions by the induced electric field. This diffusion process was continued as the ions were convected from the plasma sheet boundary layer to the double-spiral injection boundary. Inward of the injection boundary, the ions were convected adiabatically. By using as input an O(+) flux of 2.8 x 10 to the 8th per sq cm per s (w greater than 10 eV) and an H(+) flux of 5.5 x 10 to the 8th per sq cm per s (w greater than 0.63 eV), the computed distribution functions of the ions in the ring current were found to be in good agreement, over a wide range in L (4 to 8), with measurements made with the ISEE-1 satellite during a storm. This O(+) flux and a large part of the H(+) flux are consistent with the DE satellite measurements of the polar ionospheric outflow during disturbed times.

  4. Python essential reference

    CERN Document Server

    Beazley, David M

    2009-01-01

    Python Essential Reference is the definitive reference guide to the Python programming language — the one authoritative handbook that reliably untangles and explains both the core Python language and the most essential parts of the Python library. Designed for the professional programmer, the book is concise, to the point, and highly accessible. It also includes detailed information on the Python library and many advanced subjects that is not available in either the official Python documentation or any other single reference source. Thoroughly updated to reflect the significant new programming language features and library modules that have been introduced in Python 2.6 and Python 3, the fourth edition of Python Essential Reference is the definitive guide for programmers who need to modernize existing Python code or who are planning an eventual migration to Python 3. Programmers starting a new Python project will find detailed coverage of contemporary Python programming idioms.

  5. Particle-in-cell simulation of electron trajectories and irradiation uniformity in an annular cathode high current pulsed electron beam source

    Energy Technology Data Exchange (ETDEWEB)

    Jiang, Wei; Wang, Langping, E-mail: aplpwang@hit.edu.cn; Zhou, Guangxue; Wang, Xiaofeng

    2017-02-01

    Highlights: • The transmission process of electrons and irradiation uniformity was simulated. • Influence of the irradiation parameters on irradiation uniformity are discussed. • High irradiation uniformity can be obtained in a wide processing window. - Abstract: In order to study electron trajectories in an annular cathode high current pulsed electron beam (HCPEB) source based on carbon fiber bunches, the transmission process of electrons emitted from the annular cathode was simulated using a particle-in-cell model with Monte Carlo collisions (PIC-MCC). The simulation results show that the intense flow of the electrons emitted from the annular cathode are expanded during the transmission process, and the uniformity of the electron distribution is improved in the transportation process. The irradiation current decreases with the irradiation distance and the pressure, and increases with the negative voltage. In addition, when the irradiation distance and the cathode voltage are larger than 40 mm and −15 kV, respectively, a uniform irradiation current distribution along the circumference of the anode can be obtained. The simulation results show that good irradiation uniformity of circular components can be achieved by this annular cathode HCPEB source.

  6. A Single-Phase Current Source Solar Inverter with Constant Instantaneous Power, Improved Reliability, and Reduced-Size DC-Link Filter

    Science.gov (United States)

    Bush, Craig R.

    This dissertation presents a novel current source converter topology that is primarily intended for single-phase photovoltaic (PV) applications. In comparison with the existing PV inverter technology, the salient features of the proposed topology are: a) the low frequency (double of line frequency) ripple that is common to single-phase inverters is greatly reduced; b) the absence of low frequency ripple enables significantly reduced size pass components to achieve necessary DC-link stiffness and c) improved maximum power point tracking (MPPT) performance is readily achieved due to the tightened current ripple even with reduced-size passive components. The proposed topology does not utilize any electrolytic capacitors. Instead an inductor is used as the DC-link filter and reliable AC film capacitors are utilized for the filter and auxiliary capacitor. The proposed topology has a life expectancy on par with PV panels. The proposed modulation technique can be used for any current source inverter where an unbalanced three-phase operation is desires such as active filters and power controllers. The proposed topology is ready for the next phase of microgrid and power system controllers in that it accepts reactive power commands. This work presents the proposed topology and its working principle supported by with numerical verifications and hardware results. Conclusions and future work are also presented.

  7. Polar conic current sheets as sources and channels of energetic particles in the high-latitude heliosphere

    Science.gov (United States)

    Khabarova, Olga; Malova, Helmi; Kislov, Roman; Zelenyi, Lev; Obridko, Vladimir; Kharshiladze, Alexander; Tokumaru, Munetoshi; Sokół, Justyna; Grzedzielski, Stan; Fujiki, Ken'ichi; Malandraki, Olga

    2017-04-01

    The existence of a large-scale magnetically separated conic region inside the polar coronal hole has been predicted by the Fisk-Parker hybrid heliospheric magnetic field model in the modification of Burger and co-workers (Burger et al., ApJ, 2008). Recently, long-lived conic (or cylindrical) current sheets (CCSs) have been found from Ulysses observations at high heliolatitudes (Khabarova et al., ApJ, 2017). The characteristic scale of these structures is several times lesser than the typical width of coronal holes, and the CCSs can be observed at 2-3 AU for several months. CCS crossings in 1994 and 2007 are characterized by sharp decreases in the solar wind speed and plasma beta typical for predicted profiles of CCSs. In 2007, a CCS was detected directly over the South Pole and strongly highlighted by the interaction with comet McNaught. The finding is confirmed by restorations of solar coronal magnetic field lines that reveal the occurrence of conic-like magnetic separators over the solar poles both in 1994 and 2007. Interplanetary scintillation data analysis also confirms the existence of long-lived low-speed regions surrounded by the typical polar high-speed solar wind in solar minima. The occurrence of long-lived CCSs in the high-latitude solar wind could shed light on how energetic particles reach high latitudes. Energetic particle enhancements up to tens MeV were observed by Ulysses at edges of CCSs both in 1994 and 2007. In 1994 this effect was clearer, probably due to technical reasons. Accelerated particles could be produced either by magnetic reconnection at the edges of a CCS in the solar corona or in the solar wind. We discuss the role of high-latitude CCSs in propagation of energetic particles in the heliosphere and revisit previous studies of energetic particle enhancements at high heliolatitudes. We also suggest that the existence of a CCS can modify the distribution of the solar wind as a function of heliolatitude and consequently impact ionization

  8. Atomic processes, cross sections, and reaction rates necessary for modelling hydrogen-negative-ion sources and identification of optimum H- current densities

    International Nuclear Information System (INIS)

    Hiskes, J.R.

    1991-01-01

    The principal electron excitation cross sections for vibrational excitation in a hydrogen discharge are reported. In the first chamber of a two-chamber hydrogen negative-ion-source system subject to the beam-line constraint of a maximum gas pressure, the density of vibrationally excited molecules reaches an asymptote for increasing discharge current or the equivalent fast electron density. Operating near this first-chamber asymptote, there exists a spatially-dependent maximum negative-ion density in the second chamber. With the extraction grid placed at this maximum the optimum performance of a hydrogen-based system is determined. This optimum performance provides a criterion for the selection of differing source types for fusion applications

  9. Studies and optimization of Pohang Light Source-II superconducting radio frequency system at stable top-up operation with beam current of 400 mA

    International Nuclear Information System (INIS)

    Joo, Youngdo; Yu, Inha; Park, Insoo; Chun, Myunghwan; Lee, Byung-Joon; Hwang, Ilmoon; Ha, Taekyun; Shin, Seunghwan; Sohn, Younguk

    2014-01-01

    After three years of upgrading work, the Pohang Light Source-II (PLS-II) is now successfully operating. The final quantitative goal of PLS-II is a top-up user-service operation with beam current of 400 mA to be completed by the end of 2014. During the beam store test up to 400 mA in the storage ring (SR), it was observed that the vacuum pressure around the radio frequency (RF) window of the superconducting cavity rapidly increases over the interlock level limiting the availability of the maximum beam current storing. Although available beam current is enhanced by setting a higher RF accelerating voltage, it is better to keep the RF accelerating voltage as low as possible in the long time top-up operation. We investigated the cause of the window vacuum pressure increment by studying the changes in the electric field distribution at the superconducting cavity and waveguide according to the beam current. In our simulation, an equivalent physical modeling was developed using a finite-difference time-domain code. The simulation revealed that the electric field amplitude at the RF window is exponentially increased as the beam current increases, thus this high electric field amplitude causes a RF breakdown at the RF window, which comes with the rapid increase of window vacuum pressure. The RF accelerating voltage of PLS-II RF system was set to 4.95 MV, which was estimated using the maximum available beam current that works as a function of RF voltage, and the top-up operation test with the beam current of 400 mA was successfully carried out

  10. Connecting VLBI and Gaia Celestial Reference Frames

    Energy Technology Data Exchange (ETDEWEB)

    Malkin, Zinovy, E-mail: malkin@gao.spb.ru [Department of Radio Astronomy Research, The Pulkovo Astronomical Observatory, St. Petersburg (Russian Federation); Institute of Earth Sciences, St. Petersburg State University, St. Petersburg (Russian Federation); Astronomy and Cosmic Geodesy Department, Kazan Federal University, Kazan (Russian Federation)

    2016-09-12

    The current state of the link problem between radio and optical celestial reference frames is considered. The main objectives of the investigations in this direction during the next few years are the preparation of a comparison and the mutual orientation and rotation between the optical Gaia Celestial Reference Frame (GCRF) and the 3rd generation radio International Celestial Reference Frame (ICRF3), obtained from VLBI observations. Both systems, ideally, should be a realization of the ICRS (International Celestial Reference System) at micro-arcsecond level accuracy. Therefore, the link accuracy between the ICRF and GCRF should be obtained with similar error level, which is not a trivial task due to relatively large systematic and random errors in source positions at different frequency bands. In this paper, a brief overview of recent work on the GCRF–ICRF link is presented. Additional possibilities to improve the GCRF–ICRF link accuracy are discussed. The suggestion is made to use astrometric radio sources with optical magnitude to 20{sup m} rather than to 18{sup m} as currently planned for the GCRF–ICRF link. In addition, the use of radio stars is also a prospective method to obtain independent and accurate orientation between the Gaia frame and the ICRF.

  11. Connecting VLBI and Gaia celestial reference frames

    Directory of Open Access Journals (Sweden)

    Zinovy Malkin

    2016-09-01

    Full Text Available The current state of the link problem between radio and optical celestial reference frames is considered.The main objectives of the investigations in this direction during the next few years are the preparation of a comparisonand the mutual orientation and rotation between the optical it Gaia Celestial Reference Frame (GCRFand the 3rd generation radio International Celestial Reference Frame (ICRF3, obtained from VLBI observations.Both systems, ideally, should be a realization of the ICRS (International Celestial Reference System at micro-arcsecond level accuracy.Therefore, the link accuracy between the ICRF and GCRF should be obtained with similar error level, which is not a trivial taskdue to relatively large systematic and random errors in source positions at different frequency bands.In this paper, a brief overview of recent work on the GCRF--ICRF link is presented.Additional possibilities to improve the GCRF--ICRF link accuracy are discussed.The suggestion is made to use astrometric radio sources with optical magnitude to 20$^m$ rather than to 18$^m$ as currently plannedfor the GCRF--ICRF link.In addition, the use of radio stars is also a prospective method to obtain independent and accurate orientation between the Gaia frame and the ICRF.

  12. Integration of Reference Frames Using VLBI

    Science.gov (United States)

    Ma, Chopo; Smith, David E. (Technical Monitor)

    2001-01-01

    Very Long Baseline Interferometry (VLBI) has the unique potential to integrate the terrestrial and celestial reference frames through simultaneous estimation of positions and velocities of approx. 40 active VLBI stations and a similar number of stations/sites with sufficient historical data, the position and position stability of approx. 150 well-observed extragalactic radio sources and another approx. 500 sources distributed fairly uniformly on the sky, and the time series of the five parameters that specify the relative orientation of the two frames. The full realization of this potential is limited by a number of factors including the temporal and spatial distribution of the stations, uneven distribution of observations over the sources and the sky, variations in source structure, modeling of the solid/fluid Earth and troposphere, logistical restrictions on the daily observing network size, and differing strategies for optimizing analysis for TRF, for CRF and for EOP. The current status of separately optimized and integrated VLBI analysis will be discussed.

  13. Initial Beam Dynamics Simulations of a High-Average-Current Field-Emission Electron Source in a Superconducting RadioFrequency Gun

    Energy Technology Data Exchange (ETDEWEB)

    Mohsen, O. [Northern Illinois U.; Gonin, I. [Fermilab; Kephart, R. [Fermilab; Khabiboulline, T. [Fermilab; Piot, P. [Northern Illinois U.; Solyak, N. [Fermilab; Thangaraj, J. C. [Fermilab; Yakovlev, V. [Fermilab

    2018-01-05

    High-power electron beams are sought-after tools in support to a wide array of societal applications. This paper investigates the production of high-power electron beams by combining a high-current field-emission electron source to a superconducting radio-frequency (SRF) cavity. We especially carry out beam-dynamics simulations that demonstrate the viability of the scheme to form $\\sim$ 300 kW average-power electron beam using a 1+1/2-cell SRF gun.

  14. Hispanic Latin America, Spain and the Spanish-speaking Caribbean: a rich source of reference material for public health, epidemiology and tropical medicine.

    Science.gov (United States)

    Williams, John R; Bórquez, Annick; Basáñez, María-Gloria

    2008-09-30

    There is a multiplicity of journals originating in Spain and the Spanish-speaking countries of Latin America and the Caribbean (SSLAC) in the health sciences of relevance to the fields of epidemiology and public health. While the subject matter of epidemiology in Spain shares many features with its neighbours in Western Europe, many aspects of epidemiology in Latin America are particular to that region. There are also distinctive theoretical and philosophical approaches to the study of epidemiology and public health arising from traditions such as the Latin American social medicine movement, of which there may be limited awareness. A number of online bibliographic databases are available which focus primarily on health sciences literature arising in Spain and Latin America, the most prominent being Literatura Latinoamericana en Ciencias de la Salud (LILACS) and LATINDEX. Some such as LILACS also extensively index grey literature. As well as in Spanish, interfaces are provided in English and Portuguese. Abstracts of articles may also be provided in English with an increasing number of journals beginning to publish entire articles written in English. Free full text articles are becoming accessible, one of the most comprehensive sources being the Scientific Electronic Library Online (SciELO). There is thus an extensive range of literature originating in Spain and SSLAC freely identifiable and often accessible online, and with the potential to provide useful inputs to the study of epidemiology and public health provided that any reluctance to explore these resources can be overcome. In this article we provide an introduction to such resources.

  15. Dependence of ion beam current on position of mobile plate tuner in multi-frequencies microwaves electron cyclotron resonance ion source

    International Nuclear Information System (INIS)

    Kurisu, Yosuke; Kiriyama, Ryutaro; Takenaka, Tomoya; Nozaki, Dai; Sato, Fuminobu; Kato, Yushi; Iida, Toshiyuki

    2012-01-01

    We are constructing a tandem-type electron cyclotron resonance ion source (ECRIS). The first stage of this can supply 2.45 GHz and 11-13 GHz microwaves to plasma chamber individually and simultaneously. We optimize the beam current I FC by the mobile plate tuner. The I FC is affected by the position of the mobile plate tuner in the chamber as like a circular cavity resonator. We aim to clarify the relation between the I FC and the ion saturation current in the ECRIS against the position of the mobile plate tuner. We obtained the result that the variation of the plasma density contributes largely to the variation of the I FC when we change the position of the mobile plate tuner.

  16. Hispanic Latin America, Spain and the Spanish-speaking Caribbean: A rich source of reference material for public health, epidemiology and tropical medicine

    Directory of Open Access Journals (Sweden)

    Basáñez María-Gloria

    2008-09-01

    Full Text Available Abstract There is a multiplicity of journals originating in Spain and the Spanish-speaking countries of Latin America and the Caribbean (SSLAC in the health sciences of relevance to the fields of epidemiology and public health. While the subject matter of epidemiology in Spain shares many features with its neighbours in Western Europe, many aspects of epidemiology in Latin America are particular to that region. There are also distinctive theoretical and philosophical approaches to the study of epidemiology and public health arising from traditions such as the Latin American social medicine movement, of which there may be limited awareness. A number of online bibliographic databases are available which focus primarily on health sciences literature arising in Spain and Latin America, the most prominent being Literatura Latinoamericana en Ciencias de la Salud (LILACS and LATINDEX. Some such as LILACS also extensively index grey literature. As well as in Spanish, interfaces are provided in English and Portuguese. Abstracts of articles may also be provided in English with an increasing number of journals beginning to publish entire articles written in English. Free full text articles are becoming accessible, one of the most comprehensive sources being the Scientific Electronic Library Online (SciELO. There is thus an extensive range of literature originating in Spain and SSLAC freely identifiable and often accessible online, and with the potential to provide useful inputs to the study of epidemiology and public health provided that any reluctance to explore these resources can be overcome. In this article we provide an introduction to such resources.

  17. Hispanic Latin America, Spain and the Spanish-speaking Caribbean: A rich source of reference material for public health, epidemiology and tropical medicine

    Science.gov (United States)

    Williams, John R; Bórquez, Annick; Basáñez, María-Gloria

    2008-01-01

    There is a multiplicity of journals originating in Spain and the Spanish-speaking countries of Latin America and the Caribbean (SSLAC) in the health sciences of relevance to the fields of epidemiology and public health. While the subject matter of epidemiology in Spain shares many features with its neighbours in Western Europe, many aspects of epidemiology in Latin America are particular to that region. There are also distinctive theoretical and philosophical approaches to the study of epidemiology and public health arising from traditions such as the Latin American social medicine movement, of which there may be limited awareness. A number of online bibliographic databases are available which focus primarily on health sciences literature arising in Spain and Latin America, the most prominent being Literatura Latinoamericana en Ciencias de la Salud (LILACS) and LATINDEX. Some such as LILACS also extensively index grey literature. As well as in Spanish, interfaces are provided in English and Portuguese. Abstracts of articles may also be provided in English with an increasing number of journals beginning to publish entire articles written in English. Free full text articles are becoming accessible, one of the most comprehensive sources being the Scientific Electronic Library Online (SciELO). There is thus an extensive range of literature originating in Spain and SSLAC freely identifiable and often accessible online, and with the potential to provide useful inputs to the study of epidemiology and public health provided that any reluctance to explore these resources can be overcome. In this article we provide an introduction to such resources. PMID:19243576

  18. Estimation of Acoustic Particle Motion and Source Bearing Using a Drifting Hydrophone Array Near a River Current Turbine to Assess Disturbances to Fish

    Science.gov (United States)

    Murphy, Paul G.

    River hydrokinetic turbines may be an economical alternative to traditional energy sources for small communities on Alaskan rivers. However, there is concern that sound from these turbines could affect sockeye salmon (Oncorhynchus nerka), an important resource for small, subsistence based communities, commercial fisherman, and recreational anglers. The hearing sensitivity of sockeye salmon has not been quantified, but behavioral responses to sounds at frequencies less than a few hundred Hertz have been documented for Atlantic salmon (Salmo salar), and particle motion is thought to be the primary mode of stimulation. Methods of measuring acoustic particle motion are well-established, but have rarely been necessary in energetic areas, such as river and tidal current environments. In this study, the acoustic pressure in the vicinity of an operating river current turbine is measured using a freely drifting hydrophone array. Analysis of turbine sound reveals tones that vary in frequency and magnitude with turbine rotation rate, and that may sockeye salmon may sense. In addition to pressure, the vertical components of particle acceleration and velocity are estimated by calculating the finite difference of the pressure signals from the hydrophone array. A method of determining source bearing using an array of hydrophones is explored. The benefits and challenges of deploying drifting hydrophone arrays for marine renewable energy converter monitoring are discussed.

  19. Reference problems

    Digital Repository Service at National Institute of Oceanography (India)

    Varkey, M.J.

    CURRENT SCIENCE, VOL. 80, NO. 10, 25 MAY 2001 1249 tion are so high and that the gullible public will rush like lemmings to cha r- latans, often at considerable costs in terms of money, time and energy, only indicates that traditional ed ucation...

  20. Two tests of electric fields, second-order in source-velocity terms of closed, steady currents: (1) an electron beam; (2) a superconducting coil

    International Nuclear Information System (INIS)

    Kenyon, C.S.

    1980-01-01

    One particular prediction of Maxwell's theory that has been previously neglected is that the motion of charges traveling in closed loops produces no constant electric fields. This study presents and analyzes the results of two new experiments designed to test for second-order, source-velocity electric fields from steady, closed currents and analyzes another experiment in light of these fields. The first experiment employed an electron beam. The second used a niobium-titanium coil designed so that the voltage measurement configuration could be easily switched from a Faraday to a non-faraday configuration between sets of runs. The implications of the observation of a null charge on magnetically suspended superconducting spheres vis-a-vis the second-order, source-velocity fields were discussed as the third case. The observation of a null potential corresponding to a null effective charge from a hypothetical velocity-squared field in both the beam and the coil experiment placed the upper bound on a field term at 0.02 with respect a Coulomb term. An observed null charge on the suspended spheres reduced this bound to 0.001. Such an upper bound is strong evidence against alternative theories predicting a relative contribution of the order of unity for a simple velocity-squared term. A simple velocity-squared electric field would be indistinguishable from a velocity-squared charge variation. The latter test limits such a charge variation to 0.001 of the total charge. The suspended-spheres test allowed the previously neglected issue of a general second-order, source-velocity electric field to be addressed. The observed null charge in this test contradicts and thus eliminates a hypothesized, general, electric field expression containing three second-order, source-velocity terms