WorldWideScience

Sample records for current power loss

  1. Reducing AC-Winding Losses in High-Current High-Power Inductors

    DEFF Research Database (Denmark)

    Nymand, Morten; Madawala, Udaya K.; Andersen, Michael Andreas E.

    2009-01-01

    Foil windings are preferable in high-current high-power inductors to realize compact designs and to reduce dc-current losses. At high frequency, however, proximity effect will cause very significant increase in ac resistance in multi-layer windings, and lead to high ac winding losses. This paper ...

  2. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self-losses......The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...

  3. Comprehensive Power Losses Model for Electronic Power Transformer

    DEFF Research Database (Denmark)

    Yue, Quanyou; Li, Canbing; Cao, Yijia

    2018-01-01

    The electronic power transformer (EPT) has highe rpower losses than the conventional transformer. However, the EPT can correct the power factor, compensate the unbalanced current and reduce the line power losses in the distribution network.Therefore, the higher losses of the EPT and the consequent...... reduced power losses in the distribution network require a comprehensive consideration when comparing the power losses of theEPT and conventional transformer. In this paper, a comprehensive power losses analysis model for the EPT in distribution networks is proposed. By analyzing the EPT self......-losses and considering the impact of the non-unity power factor and the three-phase unbalanced current, the overall power losses in the distribution network when using the EPT to replace the conventional transformer is analyzed, and the conditions in which the application of the EPT can cause less power losses...

  4. Eddy current and total power loss separation in the iron-phosphate-polyepoxy soft magnetic composites

    International Nuclear Information System (INIS)

    Taghvaei, A.H.; Shokrollahi, H.; Janghorban, K.; Abiri, H.

    2009-01-01

    This work investigates the magnetic properties of iron-phosphate-polyepoxy soft magnetic composite materials. FTIR spectra, EDX analysis, distribution maps, X-ray diffraction pattern and density measurements show that the particles surface layer contains a thin layer of nanocrystalline/amorphous phosphate with high coverage of powders surface. In this paper, a formula for calculating the eddy current loss and total loss components by loss separation method is presented and finally the different parts of power losses are calculated. The results show that, the contribution of eddy current in the bulk material for single coating layer (k b = 0.18) is higher in comparison with double coating layer (k b = 0.09). Moreover, iron-phosphate-polyepoxy composites (P = 0.000004f 2 ) have lower power loss in comparison with iron-phosphate composites (P = 0.00002f 2 ).

  5. Analysis of eddy current loss in high-Tc superconducting power cables with respect to various structure of stabilizer

    International Nuclear Information System (INIS)

    Choi, S. J.; Song, M. K.; Lee, S. J.; Cho, J. W.; Sim, K. D.

    2005-01-01

    The High-Tc superconducting power cable consists of a multi-layer high-Tc superconducting cable core and a stabilizer which is used to bypass the current at fault time. Eddy current loss is generated in the stabilizer in normal operating condition and affects the whole system. In this paper, the eddy current losses are analyzed with respect to various structure of stabilizer by using opera-3d. Moreover, optimal conditions of the stabilizer are derived to minimize the eddy current losses from the analyzed results. The obtained results could be applied to the design and manufacture of the high-Tc superconducting power cable system.

  6. Study of eddy current power loss from outer-winding coils of a magnetic position sensor

    International Nuclear Information System (INIS)

    Liu, C.-P.; Lin, T.-K.; Chang, Y.-H.; Yu, C.-S.; Wu, K.-T.; Wang, S.-J.; Ying, T.-F.; Huang, D.-R.

    2000-01-01

    The present analysis is concerned with eddy current power loss of a magnetic position sensor, which arises from a non-uniform flux linkage distribution between magnetic material and position sensor. In the paper, a magnetic position sensor system is simplified to be an outer-winding coil along the axial direction of a low carbon steel bar, and developed a numerical model to compute the electrical characteristics by an excited current source. According to the simulated and measured data in this proposed model from 2.52 to 11.37 Oes, eddy current power losses of conducting material have a variation of 6.1% and 9.77%, respectively. Finally, the phases of waveform of the induced output voltage will also be obtained in the conducting material, and have a variation of 3.68% obtained by using the current source in the proposed model

  7. Study of eddy current power loss from outer-winding coils of a magnetic position sensor

    CERN Document Server

    Liu, C P; Chang, Y H; Yu, C S; Wu, K T; Wang, S J; Ying, T F; Huang, D R

    2000-01-01

    The present analysis is concerned with eddy current power loss of a magnetic position sensor, which arises from a non-uniform flux linkage distribution between magnetic material and position sensor. In the paper, a magnetic position sensor system is simplified to be an outer-winding coil along the axial direction of a low carbon steel bar, and developed a numerical model to compute the electrical characteristics by an excited current source. According to the simulated and measured data in this proposed model from 2.52 to 11.37 Oes, eddy current power losses of conducting material have a variation of 6.1% and 9.77%, respectively. Finally, the phases of waveform of the induced output voltage will also be obtained in the conducting material, and have a variation of 3.68% obtained by using the current source in the proposed model.

  8. Measuring Plasma Formation Field Strength and Current Loss in Pulsed Power Diodes

    Energy Technology Data Exchange (ETDEWEB)

    Johnston, Mark D. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Patel, Sonal G. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Falcon, Ross Edward [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cartwright, Keith [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Kiefer, Mark L. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Cuneo, Michael E. [Sandia National Lab. (SNL-NM), Albuquerque, NM (United States). Advanced Radiographic Technologies Dept.; Maron, Yitzhak [Weizmann Inst. of Science, Rehovot (Israel)

    2017-11-01

    This LDRD investigated plasma formation, field strength, and current loss in pulsed power diodes. In particular the Self-Magnetic Pinch (SMP) e-beam diode was studied on the RITS-6 accelerator. Magnetic fields of a few Tesla and electric fields of several MV/cm were measured using visible spectroscopy techniques. The magnetic field measurements were then used to determine the current distribution in the diode. This distribution showed that significant beam current extends radially beyond the few millimeter x-ray focal spot diameter. Additionally, shielding of the magnetic field due to dense electrode surface plasmas was observed, quantified, and found to be consistent with the calculated Spitzer resistivity. In addition to the work on RITS, measurements were also made on the Z-machine looking to quantify plasmas within the power flow regions. Measurements were taken in the post-hole convolute and final feed gap regions on Z. Dopants were applied to power flow surfaces and measured spectroscopically. These measurements gave species and density/temperature estimates. Preliminary B-field measurements in the load region were attempted as well. Finally, simulation work using the EMPHASIS, electromagnetic particle in cell code, was conducted using the Z MITL conditions. The purpose of these simulations was to investigate several surface plasma generations models under Z conditions for comparison with experimental data.

  9. Post-tensioning tendon force loss detection using low power pulsed eddy current measurement

    Science.gov (United States)

    Kim, Ji-Min; Lee, Jun; Sohn, Hoon

    2018-04-01

    In the field of bridge engineering, pre-fabrication of a bridge member and its construction in site have been issued and studied, which achieves improved quality and rapid construction. For integration of those pre-fabricated segments into a structural member (i.e., a concrete slab, girder and pier), post-tensioning (PT) technique is adopted utilizing a high-strength steel tendon, and an effective investigation of the remaining PT tendon force is essential to assure an overall structural integrity. This study proposes a pulsed eddy current based tendon force loss detection system. A compact eddy current sensor is designed to be installed on the surface of an anchor holding a steel PT tendon. The intensity of the induced eddy current varies with PT tendon force alteration due to the magnetostriction effect of a ferromagnetic material. The advantages of the proposed system are as follows: (1) low power consumption, (2) rapid inspection, and (3) simple installation. Its performance was validated experimentally in a full-scale lab test of a 3.3-m long, 15.2-mm diameter mono-tendon that was tensioned using a universal testing machine. Tendon force was controlled from 20 to 180 kN with 20 kN interval, and eddy current responses were measured and analyzed at each force condition. The proposed damage index and the amount of force loss of PT tendon were monotonically related, and an excessive loss as much as 30 % of an initially-introduced tendon force was successfully predicted.

  10. Some aspects of stray losses in large power transformers

    International Nuclear Information System (INIS)

    Valkovic, Zvonimir

    2002-01-01

    The paper presents some results of the investigation of stray losses in power transformers that are caused by high-current loops. The investigation was focused on: a) additional losses in tank cover around high-current bushings and the way of their reduction, b) extra leakage flux and additional losses due to high current delta-connections. The insertion of nonmagnetic gaps between the phase bushings reduces the extra cover losses more than three times. A nonmagnetic plate around the high-current bushings reduces these extra losses practically to zero. The extra losses due to the high-current delta-connections could be significant for the transformer loss level. These extra losses could be controlled (reduced) by the design layout of the delta-connections. (Author)

  11. Experimental study on using a high-temperature superconducting inductor for power loss reduction in an active power filter

    International Nuclear Information System (INIS)

    Chao, C; To, H P; Grantham, C; Rahman, M F

    2006-01-01

    An active power filter improves the electric power quality through the compensation of harmonics in the power network. A current-source active power filter using a conventional copper inductor for its energy storage has a significant power loss. The loss in the copper inductor can be substantially reduced by using a high-temperature superconducting (HTS) inductor instead. Experiments have been conducted on a prototype current-source active power filter for studying the power loss reduction effect and harmonics compensation performance of the active power filter using a HTS inductor. Experimental results are analysed and discussed in this paper

  12. Comment on 'Relation between space charge limited current and power loss in open drift tubes' [Phys. Plasmas 13, 073101 (2006)

    International Nuclear Information System (INIS)

    Swanekamp, S. B.; Schumer, J. W.

    2007-01-01

    In Phys Plasmas 13, 073101 (2006), the drop in the space-charge-limited (SCL) current for a beam injected into a space with an open boundary is analyzed with an electromagnetic particle-in-cell code. The authors explained the power loss observed at the open boundary as the loss of electromagnetic radiation created from the deceleration of electrons in the gap, and they developed an effective voltage theory to predict the drop in the SCL current observed in the simulations. In this Comment, we show that, provided the current remains below the SCL value, the electric and magnetic fields are constant in time so that power loss from the open boundary is a dc phenomenon with no rf power leaving through the boundary. We show that the electric and magnetic fields are static in time and static fields DO NOT RADIATE. Instead, the electron beam charges the collector plate, which causes a real electrostatic electric field to develop. The electron energy loss is not due to radiation but rather to the work done by this electrostatic field on the electrons as they move across the gap. This is precisely the energy dissipated in the matched resistance across the open boundary, which is a consequence of the boundary condition. Furthermore, since a real electrostatic potential develops, the voltage drop is real and there is no need to call the voltage drop an effective voltage

  13. Study on classical and excess eddy currents losses of Terfenol-D

    Energy Technology Data Exchange (ETDEWEB)

    Talebian, Soheil; Hojjat, Yousef [Department of Mechanical Engineering, Tarbiat Modares University, Tehran (Iran, Islamic Republic of); Ghodsi, Mojtaba [Department of Mechanical and Industrial Engineering, Sultan Qaboos University, Muscat (Oman); Karafi, Mohammad Reza [Department of Mechanical Engineering, Tarbiat Modares University, Tehran (Iran, Islamic Republic of)

    2015-08-15

    In the present paper, classical and excess eddy currents losses of Terfenol-D are studied and effects of magnetic field frequency, peak of magnetic flux density and diameter of Terfenol-D on the eddy currents losses are investigated. To provide reliable data for the purpose of the paper, an experimental laboratory is fabricated and used to obtain major and minor hysteresis loops of Terfenol-D at different frequencies. In theoretical study, initially an analytical model based on uniform distribution of magnetic flux is developed which yields to calculation of classical eddy currents losses. Then, another eddy currents model based on non-uniform distribution of magnetic flux and nonlinear diffusion of electromagnetic fields is presented. The difference between output values of the two models is identified as excess eddy currents losses. Obtained results show that the values of excess losses are generally larger than classical losses and applying just classical model leads to wrong calculation of actual value of eddy currents losses. For the results obtained from two above models, empirical models with respect to the magnetic field frequency and the peak value of magnetic flux density are achieved which can predict the eddy currents losses precisely. To validate the empirical relations, experiments are repeated at a new frequency and values of power losses calculated from analytical equations are compared with the predicted values of the empirical models. The results point towards possibility to use the obtained empirical relations in order to calculate the classical and excess eddy currents losses of Terfenol-D at the frequencies below 200 Hz and different values of magnetic flux density. - Highlights: • Classical eddy currents loss of Terfenol-D is studied using Maxwell's laws. • Excess eddy currents loss of Terfenol-D is studied using Mayergoyz nonlinear model. • Effects of Terfenol-D geometry on the eddy currents losses are investigated. • Power

  14. Power losses in electrical networks depending on weather conditions

    International Nuclear Information System (INIS)

    Zhelezko, Yu. S.; Kostyushko, V. A.; Krylov, S. V.; Nikiforov, E. P.; Savchenko, O. V.; Timashova, L. V.; Solomonik, E. A.

    2005-01-01

    Specific power losses to corona and to leakage currents over overhead insulators are presented for 110 - 750-kV transmission lines with different phase design and pole types for different weather conditions. Consumption of electric energy for ice melting on conductors of various cross sections is evaluated. Meteorological data of 1372 weather stations in Russia are processed for a period of 10 years. The territory of the country is divided into 7 regions with approximately homogeneous weather conditions. Specific power losses to corona and leakage currents over overhead insulators are presented for every region

  15. Impact of Neutral Point Current Control on Copper Loss Distribution of Five Phase PM Generators Used in Wind Power Plants

    Directory of Open Access Journals (Sweden)

    ARASHLOO, R. S.

    2014-05-01

    Full Text Available Efficiency improvement under faulty conditions is one of the main objectives of fault tolerant PM drives. This goal can be achieved by increasing the output power while reducing the losses. Stator copper loss not only directly affects the total efficiency, but also plays an important role in thermal stress generations of iron core. In this paper, the effect of having control on neutral point current is studied on the efficiency of five-phase permanent magnet machines. Open circuit fault is considered for both one and two phases, and the distribution of copper loss along the windings are evaluated in each case. It is shown that only by having access to neutral point, it is possible to generate less stator thermal stress and more mechanical power in five-phase permanent magnet generators. Wind power generation and their applications are kept in mind, and the results are verified via simulations and experimental tests on an outer-rotor type of five-phase PM machine.

  16. Reduction technique of drop voltage and power losses to improve power quality using ETAP Power Station simulation model

    Science.gov (United States)

    Satrio, Reza Indra; Subiyanto

    2018-03-01

    The effect of electric loads growth emerged direct impact in power systems distribution. Drop voltage and power losses one of the important things in power systems distribution. This paper presents modelling approach used to restructrure electrical network configuration, reduce drop voltage, reduce power losses and add new distribution transformer to enhance reliability of power systems distribution. Restructrure electrical network was aimed to analyse and investigate electric loads of a distribution transformer. Measurement of real voltage and real current were finished two times for each consumer, that were morning period and night period or when peak load. Design and simulation were conduct by using ETAP Power Station Software. Based on result of simulation and real measurement precentage of drop voltage and total power losses were mismatch with SPLN (Standard PLN) 72:1987. After added a new distribution transformer and restructrured electricity network configuration, the result of simulation could reduce drop voltage from 1.3 % - 31.3 % to 8.1 % - 9.6 % and power losses from 646.7 watt to 233.29 watt. Result showed, restructrure electricity network configuration and added new distribution transformer can be applied as an effective method to reduce drop voltage and reduce power losses.

  17. ANALYSIS OF THE HARMONIC LOSSES WITH ARTIFICIAL NEURAL NETWORKS IN UNBALANCED SYSTEM LOSSES USING BALANCED ELECTRIC POWER SYSTEM DATA

    Directory of Open Access Journals (Sweden)

    Aslan İNAN

    2005-01-01

    Full Text Available The losses in the power systems should be low as possible as. Saving energy instead of loses (kWh in power utilities can supply much more energy to the consumers. The lower losses the more energy is saved and thus the power system becomes more economical. In recent years, the increasing number of applications and power ratings of the devices which have nonlinear voltage-current characteristics cause voltage waveform distortion and additional losses. While evaluating losses considering harmonics will provide more contribution to obtain more accurate results. In this study, Artificial Neural Networks (ANN method has been presented to predict the harmonic losses in unbalanced power systems by using the data from balanced power system with nonlinear loads.

  18. Standby-Loss Elimination in Server Power Supply

    Directory of Open Access Journals (Sweden)

    Jong-Woo Kim

    2017-07-01

    Full Text Available In a server power system, a standby converter is required in order to provide the standby output, monitor the system’s status, and communicate with the server power system. Since these functions are always required, losses from the standby converter are produced even though the system operates in normal mode. For these reasons, the losses deteriorate the total efficiency of the system. In this paper, a new structure is proposed to eliminate the losses from the standby converter of a server power supply. The key feature of the proposed structure is that the main direct current (DC/DC converter substitutes all of the output power of the standby converter, and the standby converter is turned off in normal mode. With the proposed structure, the losses from the standby converter can be eliminated in normal mode, and this leads to a higher efficiency in overall load conditions. Although the structure has been proposed in the previous work, very important issues such as a steady state analysis, the transient responses, and how to control the standby converter are not discussed. This paper presents these issues further. The feasibility of the proposed structure has been verified with 400 V link voltage, 12 V/62.5 A main output, and a 12 V/2.1 A standby output server power system.

  19. Development of low-power loss Mn–Zn ferrites using microwave ...

    Indian Academy of Sciences (India)

    Unknown

    sinusoidal voltage of 25 V with frequency, 1 MHz. The efficiency and surface rise of temperature of trans- former were found to be high and low, respectively. Keywords. Ferrites; microwave sintering; conventional sintering; power loss; hysteresis loss; eddy current loss; transformer; high frequency applications. 1. Introduction.

  20. ACCOUNTING OF REACTIVE POWER COMPENSATION LEVEL AT PAYMENT CALCULATION OF TECHNOLOGICAL CONSUMPTION (LOSSES OF ELECTRIC POWER FOR ITS TRANSMISSION IN POWER NETWORK

    Directory of Open Access Journals (Sweden)

    E. P. Zabello

    2005-01-01

    Full Text Available The method is proposed to make a correction in payment for consumption of reactive energy and power which is attributed to deviation of actual activation energy losses for reactive power compensation from their standard value. It is recommended to calculate standard loss values for every voltage level and actual loss values are to be determined with the help of application of remote electronic accounting means in the current mode of power consumption.

  1. The count of losses by eddy currents in the windings of electric motors with hollow anchor

    Directory of Open Access Journals (Sweden)

    N. V. Pribylova

    2017-01-01

    Full Text Available Given the rationale of taking into account losses on eddy currents in the windings of a low-inertia DC motors with offered magnetoelectric systems. Increased in recent years, the power of these motors (through the use of highly coercive magnets permanent caused an increase in the volume of copper in the air gap and the magnetic induction values. All this has values given rise to significant eddy currents in the windings made in the air gap, and hence the necessity of taking into account losses from these currents. The experimentally obtained dependence of the losses on eddy currents on the frequency of rotation for a DC motor with a hollow anchor with a power of 350 watts. The magnitude of these losses can reach 30% of the nominal power of the motor. Described mechanism of occurrence of losses. Eddy currents occur in areas with variable magnetic flux and cause the appearance of force, which is directed toward the velocity vector and inhibits the anchor. The directions of these currents, the vectors of magnetic induction, magnetic field and force acting on the conductor winding and a braking anchor. The proposed methods reduce losses: crushing contours of eddy currents and achieve uniform distribution of magnetic induction in the interpolar space of the motor. Shows their strengths and weaknesses. The crushing circuits of windings occur surge currents. To eliminate the losses on the surge currents it is necessary to apply a transposition of the conductors. Given a refined formula for finding the losses on eddy currents in the armature winding, the conductors of which is made in the form of a harness of several wires. Formula has shown a good convergence with experimental data.

  2. Dielectric loss against piezoelectric power harvesting

    Science.gov (United States)

    Liang, Junrui; Shu-Hung Chung, Henry; Liao, Wei-Hsin

    2014-09-01

    Piezoelectricity is one of the most popular electromechanical transduction mechanisms for constructing kinetic energy harvesting systems. When a standard energy harvesting (SEH) interface circuit, i.e., bridge rectifier plus filter capacitor, is utilized for collecting piezoelectric power, the previous literature showed that the power conversion can be well predicted without much consideration for the effect of dielectric loss. Yet, as the conversion power gets higher by adopting power-boosting interface circuits, such as synchronized switch harvesting on inductor (SSHI), the neglect of dielectric loss might give rise to deviation in harvested power estimation. Given the continuous progress on power-boosting interface circuits, the role of dielectric loss in practical piezoelectric energy harvesting (PEH) systems should receive attention with better evaluation. Based on the integrated equivalent impedance network model, this fast track communication provides a comprehensive study on the susceptibility of harvested power in PEH systems under different conditions. It shows that, dielectric loss always counteracts piezoelectric power harvesting by causing charge leakage across piezoelectric capacitance. In particular, taking corresponding ideal lossless cases as references, the counteractive effect might be aggravated under one of the five conditions: larger dielectric loss tangent, lower vibration frequency, further away from resonance, weaker electromechanical coupling, or using power-boosting interface circuit. These relationships are valuable for the study of PEH systems, as they not only help explain the role of dielectric loss in piezoelectric power harvesting, but also add complementary insights for material, structure, excitation, and circuit considerations towards holistic evaluation and design for practical PEH systems.

  3. Dielectric loss against piezoelectric power harvesting

    International Nuclear Information System (INIS)

    Liang, Junrui; Shu-Hung Chung, Henry; Liao, Wei-Hsin

    2014-01-01

    Piezoelectricity is one of the most popular electromechanical transduction mechanisms for constructing kinetic energy harvesting systems. When a standard energy harvesting (SEH) interface circuit, i.e., bridge rectifier plus filter capacitor, is utilized for collecting piezoelectric power, the previous literature showed that the power conversion can be well predicted without much consideration for the effect of dielectric loss. Yet, as the conversion power gets higher by adopting power-boosting interface circuits, such as synchronized switch harvesting on inductor (SSHI), the neglect of dielectric loss might give rise to deviation in harvested power estimation. Given the continuous progress on power-boosting interface circuits, the role of dielectric loss in practical piezoelectric energy harvesting (PEH) systems should receive attention with better evaluation. Based on the integrated equivalent impedance network model, this fast track communication provides a comprehensive study on the susceptibility of harvested power in PEH systems under different conditions. It shows that, dielectric loss always counteracts piezoelectric power harvesting by causing charge leakage across piezoelectric capacitance. In particular, taking corresponding ideal lossless cases as references, the counteractive effect might be aggravated under one of the five conditions: larger dielectric loss tangent, lower vibration frequency, further away from resonance, weaker electromechanical coupling, or using power-boosting interface circuit. These relationships are valuable for the study of PEH systems, as they not only help explain the role of dielectric loss in piezoelectric power harvesting, but also add complementary insights for material, structure, excitation, and circuit considerations towards holistic evaluation and design for practical PEH systems. (fast track communications)

  4. Flux-transfer losses in helically wound superconducting power cables

    International Nuclear Information System (INIS)

    Clem, John R; Malozemoff, A P

    2013-01-01

    Minimization of ac losses is essential for economic operation of high-temperature superconductor (HTS) ac power cables. A favorable configuration for the phase conductor of such cables has two counter-wound layers of HTS tape-shaped wires lying next to each other and helically wound around a flexible cylindrical former. However, if magnetic materials such as magnetic substrates of the tapes lie between the two layers, or if the winding pitch angles are not opposite and essentially equal in magnitude to each other, current distributes unequally between the two layers. Then, if at some point in the ac cycle the current of either of the two layers exceeds its critical current, a large ac loss arises from the transfer of flux between the two layers. A detailed review of the formalism, and its application to the case of paramagnetic substrates including the calculation of this flux-transfer loss, is presented. (paper)

  5. Design of Gear Churning Power Loss Measurement Device

    OpenAIRE

    Wang Bin; Zhou Ya Jie; Wang Ping

    2017-01-01

    To explore the impacts of gear churning power losses, a research was conducted to achieve the internal causes of power losses of churning gear by designing a gear churning power losses measurement device. The gear churning power losses could be influenced by different gear modules, the number of teeth and the axial position of gear. Finally, the impacts of gear churning power losses were discussed by comparing experimental data and theoretical data.

  6. DCS cabinet power loss analysis for CPR1000 nuclear power plant

    International Nuclear Information System (INIS)

    Zhou Liang; Zhao Yanfeng; Sun Yongbin

    2014-01-01

    The DCS overall structure of CRP1000 nuclear power plant was introduced. Based on the RPC, the signal interface character and signal processing mechanism on the key root were analyzed. By the power loss analyzing of RPC, the RPC loss power may lead reactor trip signal from anticipated transient without scram (ATWS) system. The results indicate that it is necessary to search DCS cabinet power loss analysis. Optimizing and assigning the main water flow signals can avoid trigger reactor trip signal by mistake. The DCS cabinet power loss analysis can optimize the I and C (instrumentation and control) design and increase the nuclear plant's reliability. (authors)

  7. Triple Pulse Tester - Efficient Power Loss Characterization of Power Modules

    DEFF Research Database (Denmark)

    Trintis, Ionut; Poulsen, Thomas; Beczkowski, Szymon

    2015-01-01

    In this paper the triple pulse testing method and circuit for power loss characterization of power modules is introduced. The proposed test platform is able to accurately characterize both the switching and conduction losses of power modules in a single automated process. A configuration of a half...

  8. Impacts of Ripple Current to the Loading and Lifetime of Power Semiconductor Device

    DEFF Research Database (Denmark)

    Ma, Ke; Choi, Uimin; Blaabjerg, Frede

    2017-01-01

    The thermal loading of power electronics devices is determined by many factors and has being a crucial design consideration because it is closely related to the reliability and cost of the converter system. In this paper the impacts of the ripple current to the loss and thermal loading, as well...... as reliability performances of power devices are comprehensively investigated and tested. It is concluded that the amplitude of ripple current may modify the loss and thermal loading of the power devices, especially under the conditions of converter with low power output, and thus the lifetime of devices could...

  9. Automatic supervision and fault detection of PV systems based on power losses analysis

    Energy Technology Data Exchange (ETDEWEB)

    Chouder, A.; Silvestre, S. [Electronic Engineering Department, Universitat Politecnica de Catalunya, C/Jordi Girona 1-3, Campus Nord UPC, 08034 Barcelona (Spain)

    2010-10-15

    In this work, we present a new automatic supervision and fault detection procedure for PV systems, based on the power losses analysis. This automatic supervision system has been developed in Matlab and Simulink environment. It includes parameter extraction techniques to calculate main PV system parameters from monitoring data in real conditions of work, taking into account the environmental irradiance and module temperature evolution, allowing simulation of the PV system behaviour in real time. The automatic supervision method analyses the output power losses, presents in the DC side of the PV generator, capture losses. Two new power losses indicators are defined: thermal capture losses (L{sub ct}) and miscellaneous capture losses (L{sub cm}). The processing of these indicators allows the supervision system to generate a faulty signal as indicator of fault detection in the PV system operation. Two new indicators of the deviation of the DC variables respect to the simulated ones have been also defined. These indicators are the current and voltage ratios: R{sub C} and R{sub V}. Analysing both, the faulty signal and the current/voltage ratios, the type of fault can be identified. The automatic supervision system has been successfully tested experimentally. (author)

  10. Automatic supervision and fault detection of PV systems based on power losses analysis

    International Nuclear Information System (INIS)

    Chouder, A.; Silvestre, S.

    2010-01-01

    In this work, we present a new automatic supervision and fault detection procedure for PV systems, based on the power losses analysis. This automatic supervision system has been developed in Matlab and Simulink environment. It includes parameter extraction techniques to calculate main PV system parameters from monitoring data in real conditions of work, taking into account the environmental irradiance and module temperature evolution, allowing simulation of the PV system behaviour in real time. The automatic supervision method analyses the output power losses, presents in the DC side of the PV generator, capture losses. Two new power losses indicators are defined: thermal capture losses (L ct ) and miscellaneous capture losses (L cm ). The processing of these indicators allows the supervision system to generate a faulty signal as indicator of fault detection in the PV system operation. Two new indicators of the deviation of the DC variables respect to the simulated ones have been also defined. These indicators are the current and voltage ratios: R C and R V . Analysing both, the faulty signal and the current/voltage ratios, the type of fault can be identified. The automatic supervision system has been successfully tested experimentally.

  11. Low field critical currents and ac losses of thin film niobium--tin superconductors

    International Nuclear Information System (INIS)

    Howard, R.E.

    1977-01-01

    The results of a study of the low field critical current and ac loss properties of niobium-tin thin films and layered composites fabricated by electron-beam coevaporation are presented. Particular emphasis is placed upon determining the suitability of this material for use as a conductor in a superconducting power transmission line. Chapter I contains a summary of this work and its major results together with an introduction to the scientific and engineering concepts associated with a superconducting power transmission line. Chapter II is a discussion of the physics of current transport and the associated loss mechanisms in a type-II superconductor. Chapter III gives the details of the electron-beam coevaporation technique developed to fabricate the samples for this study. Also discussed in this chapter are the effects of the evaporation conditions on the growth morphology of the niobium-tin films. Chapter IV presents the details of the experimental techniques developed to measure the ac loss and critical current in these samples as a function of temperature. Chapter V shows the dependence of the critical current of these films and composites on temperature, magnetic field, and on the number of artificially introduced pinning centers in the layered composites. Experimental results are also presented concerning the stability of these conductors against flux jumps. Chapter VI is a discussion of the ac losses in these samples. Detailed comparisons are made between the measured loss and the predictions of the critical state model

  12. Current status of low power/shutdown PSA and accident sequence analysis for loss of RHR during mid-loop operation

    International Nuclear Information System (INIS)

    Park, Chang Kyu; Choi, Young; Kim, Tae Woon; Jin, Young Ho

    1994-07-01

    Probabilistic safety assessment (PSA) has been applied to only full-power operation of nuclear power plant (NPP), but some events which were recently occurred could reach severe plant damage state. Thus, various countries around the world have focused their interests on the evaluation for low power/shutdown (LP/S) operation. This report covers the main stream of LP/S PSA methodology, current status of LP/S PSA practices and results, and accident sequence analysis for loss of RHR during mid-loop operation. Therefore this report would be helpful for us to practice LP/S PSA for YGN 5,6 NPP which will be built in the near future. Also the results of accident sequence analysis show that operator's mis-diagnosis and failure of recovery action would initiate core damage during LP/S operation. In summary, overall environmental improvements (equipments, procedures, Tech Spec, etc, ...) and operating support system will be very useful to reduce risk during LP/S operation. (Author) 5 figs., 9 tabs

  13. Analysis of losses within SMES system for compensating output fluctuation of wind power farm

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. I.; Kim, J. H.; Le, T. D.; Lee, D. H.; Kim, H. M. [Jeju National University, Jeju (Korea, Republic of); Yoon, Y. S. [Dept. of Electrical Engineering, Shin Ansan University, Ansan (Korea, Republic of); Yoon, K. Y. [Dept. of lectrical and Electronic Engineering, Yonsei University, Seoul (Korea, Republic of)

    2014-12-15

    Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

  14. Analysis of losses within SMES system for compensating output fluctuation of wind power farm

    International Nuclear Information System (INIS)

    Park, S. I.; Kim, J. H.; Le, T. D.; Lee, D. H.; Kim, H. M.; Yoon, Y. S.; Yoon, K. Y.

    2014-01-01

    Output fluctuation which is generated in wind power farm can hinder stability of total power system. The electric energy storage (EES) reduces unstable output, and superconducting magnetic energy storage (SMES) of various EESs has the proper performance for output compensation of wind power farm since it charges and discharges large scale power quickly with high efficiency. However, because of the change of current within SMES, the electromagnetic losses occur in the process of output compensation. In this paper, the thermal effect of the losses that occur in SMES system while compensating in wind power farm is analyzed. The output analysis of wind power farm is processed by numerical analysis, and the losses of SMES system is analyzed by 3D finite element analysis (FEA) simulation tool.

  15. Improved Eddy-current Field Loss Model and Scaling Index for Magnets of Permanent Magnet Synchronous Motors

    Directory of Open Access Journals (Sweden)

    Zhang Lei

    2015-01-01

    Full Text Available The paper gives detailed systematic researches on the mechanism and key factors of eddy-current losses in rotor magnets of high power-density permanent magnet synchronous motors(PMSMs. Firstly, this paper establishes quantitative mathematic model of eddy-current losses for surface-mounted PMSM based on eddy current field model and Maxwell equations. Then, a scaling index is put forward to weigh the key factors relevant to the eddy-current losses in magnets. At the same time, the principles of eddy-current losses in prototype PMSM are analyzed by the finite element analysis (FEA software. The contents researched in the paper have practical reference values for design and reliability analysis of PMSMs.

  16. Alternating current loss characteristics in (bismuth,lead)SCCO and yttrium barium copper oxide superconducting tapes

    Science.gov (United States)

    Nguyen, Doan Ngoc

    Alternating current (AC) loss and current carrying capacity are two of the most crucial considerations in large-scale power applications of high temperature superconducting (HTS) conductors. AC losses result in an increased thermal load for cooling machines, and thus increased operating costs. Furthermore, AC losses can stimulate quenching phenomena or at least decrease the stability margin for superconducting devices. Thus, understanding AC losses is essential for the development of HTS AC applications. The main focus of this dissertation is to make reliable total AC loss measurements and interpret the experimental results in a theoretical framework. With a specially designed magnet, advanced total AC loss measurement system in liquid nitrogen (77 K) has been successfully built. Both calorimetric and electromagnetic methods were employed to confirm the validity of the measured results and to have a more thorough understanding of AC loss in HTS conductors. The measurement is capable of measuring total AC loss in HTS tapes over a wide range of frequency and amplitude of transport current and magnetic field. An accurate phase control technique allows measurement of total AC loss with any phase difference between the transport current and magnetic field by calorimetric method. In addition, a novel total AC loss measurement system with variable temperatures from 30 K to 100 K was successfully built and tested. Understanding the dependence of AC losses on temperature will enable optimization of the operating temperature and design of HTS devices. As a part of the dissertation, numerical calculations using Brandt's model were developed to study electrodynamics and total AC loss in HTS conductors. In the calculations, the superconducting electrical behavior is assumed to follow a power-law model. In general, the practical properties of conductors, including field-dependence of critical current density Jc, n-value and non-uniform distribution of Jc, can be accounted for in

  17. Thermal Impact Analysis of Circulating Current in High Power Modular Online Uninterruptible Power Supplies Application

    DEFF Research Database (Denmark)

    Zhang, Chi; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2017-01-01

    In modular uninterruptible power supplies (UPSs), several DC/AC modules are required to work in parallel. This structure allows the system to be more reliable and flexible. These DC/AC modules share the same DC bus and AC critical bus. Module differences, such as filter inductor, filter capacitor......, control parameters, and so on, will make it possible for the potential zero sequence current to flow among the modules. This undesired type of circulating current will bring extra losses to the power semiconductor devices in the system, which should be paid special attention in high power application...... scenarios. In this paper, plug’n’play modules and cycle control are discussed and validated through experimental results. Moreover, potential zero sequence circulating current impact on power semiconductor devices thermal performance is also analyzed in this paper....

  18. Temperature dependence of critical current and transport current losses of 4 mm YBCO coated conductors manufactured using nonmagnetic substrate

    Science.gov (United States)

    Kvitkovic, J.; Hatwar, R.; Pamidi, S. V.; Fleshler, S.; Thieme, C.

    2015-12-01

    The temperature dependence of the critical current and AC losses were measured on American Superconductor Corporation's (AMSC) second generation high temperature superconducting (2G HTS) wire produced by Rolling Assisted Biaxially Textured Substrate (RABiTS) and Metal Organic Deposition (MOD) process. Wires manufactured with two types of substrates were characterized. The magnetic substrate with composition Ni5a%W exhibits a magnetic signature and has non-negligible AC losses in AC power applications. A new nonmagnetic substrate with an alloy composition Ni9a%W has been developed by AMSC to address the AC losses in 2G HTS. The data presented show that the performance of the new conductor is identical to the conductor with magnetic substrate in terms of critical current density. The data on AC losses demonstrate the absence of ferromagnetic loss component in the new conductor and significantly reduced AC losses at low to moderate values of I/Ic. The reduced losses will translate into reduced capital costs and lower operating costs of superconducting electrical devices for AC applications.

  19. MVA power flow and loss analysis for electricity market

    International Nuclear Information System (INIS)

    Wu, Z.Q.; Chen, G.Z.

    2001-01-01

    MVA power-flow and loss analysis is the basis for allocating the fixed costs and power losses under electricity-market deregulation. It is pointed out that the decomposition allocation of active and reactive power losses is not reasonable. The theory of active and reactive loss allocation and branch-power-flow decomposition has been proposed. Various contributory factors have been deduced. These contributory factors include the contribution factors of the active and reactive generation power, load-power-to-branch flows, the contribution factors of active and reactive generation power to active and reactive load power, the contribution factors of active and reactive load power to generation power, and the contribution factors of active and reactive load power and active and reactive generation power to line power losses. The detailed calculation results are presented and analysed, demonstrating that the theory presented provides a good charging algorithm for all the market participants. (Author)

  20. Synthesis of a low loss Mn–Zn ferrite for power applications

    Energy Technology Data Exchange (ETDEWEB)

    Tsakaloudi, Vasiliki, E-mail: vikaki@cperi.certh.gr [Laboratory of Inorganic Materials, Chemical Process and Energy Resources Institute, Centre for Research and Technology Hellas, 57001 Thermi-Thessaloniki (Greece); Zaspalis, Vassilios [Laboratory of Inorganic Materials, Chemical Process and Energy Resources Institute, Centre for Research and Technology Hellas, 57001 Thermi-Thessaloniki (Greece); Laboratory of Materials Technology, Department of Chemical Engineering, Aristotle University of Thessaloniki, 54124 Thessaloniki (Greece)

    2016-02-15

    Current market trends of the switching power supplies industry require even lower energy losses in power conversion systems with maintenance of satisfactory initial permeability levels. Typical operation conditions refer to a frequency of 100 kHz, an induction level of 200 mT and a steady state temperature of 100° C. In this work the development of a polycrystalline Mn–Zn ferrite material that exhibits initial relative magnetic permeability above 2500 and very low power losses at 100 kHz, 200 mmT and 100° C is presented. The Mn–Zn ferrite samples were prepared by the conventional solid state reaction method. Sintering was performed under controlled atmosphere conditions. The combinatorial role of TiO{sub 2} and CoO together with Zn content, as well as the effects of the process parameters on the magnetic performance of the Mn–Zn ferrite was evaluated. It is shown that the development of the adequate polycrystalline microstructure that is characterized by (a) high sintered density, (b) homogenous grain size that is free of morphological or chemical pinning defects and (c) high resistivity grain boundary structure, can be achieved by means of appropriate compositional and dopant adjustment, anisotropy control and specific resistivity optimization. The newly developed Mn–Zn ferrite is characterized by high sintered density of 4.91 g/cm{sup 3}, initial magnetic permeability of 2512 (at 10 kHz, 0.1 mT, 25 °C), high saturation magnetic flux density of 560 mT (at 10 kHz, 1200 A/m, 25 °C) and very low power losses (Pv) of 224 mW/cm{sup 3} (at 100 kHz, 200 mT, 100 °C) combined with very low power losses of 470 mW/cm{sup 3} even at room temperature, establishing it as ideal for power applications. - Highlights: • Mn–Zn ferrites for power applications are prepared by solid state reaction. • Optimal doping levels of TiO{sub 2} and CoO for low power losses are determined. • A slow cooling rate during sintering improves the resistivity and power losses.

  1. Losses in German nuclear power plants

    International Nuclear Information System (INIS)

    Abinger, R.

    1982-01-01

    The author illustrates the special features of engineering insurance for nuclear power plants. The shares of the Allianz Versicherungs-AG in the insurance of construction and erection work and in machinery insurance are dealt with. Risk estimation is usually based on statistical analysis of losses. Loss analysis in the conventional sector of nuclear power plants shows typical characteristics of traditional erection and machinery losses. In the nuclear field, however, costs are greatly increased by added safety measures. For this reason, additional cover is allocated and incorporated in premium assessment. Examples from erection and machinery reveal the greater costs involved in handling losses. (orig.) [de

  2. An analytical turn-on power loss model for 650-V GaN eHEMTs

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Shen, Zhan

    2018-01-01

    This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time-d......-domain solutions to the drain-source voltage and drain current are obtained. Finally, double-pulse tests are conducted to verify the proposed power loss model. This analytical model enables an accurate and fast switching behavior characterization and power loss prediction.......This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time...

  3. Radiative energy losses from a high-current air-blast arc

    International Nuclear Information System (INIS)

    Strachan, D.C.; Lidgate, D.; Jones, G.R.

    1977-01-01

    The importance of total radiation losses from high-current arcs burning in highly accelerated air flows representative of conditions existing in commercial gas-blast switchgear has been investigated. Such losses have been measured both in the high-pressure region upstream of a shaped orifice, where gas velocities are low, and in the region downstream where velocities become supersonic and pressure conditions approach ambient. The dominance of upstream electrode vapor as the source of plasma radiation losses is demonstrated and the importance of radiated losses within the arc energy balance is examined using measured values of axial electric field. For upstream electrodes of elkonite (sintered copper/tungsten) as used in high-power gas-blast circuit breakers, it is shown that some 30--40% of the electrical energy input upstream of the orifice is lost as radiation, while downstream this figure becomes 10--20%. The effect of reservoir pressure on arc electric fields is examined and the contribution to this effect of radiation losses is quantified

  4. Minimization of the power losses in televisions. Report no. 1

    Energy Technology Data Exchange (ETDEWEB)

    Oestergaard, Leo

    1996-03-01

    In order to achieve a simple and a manageable circuit to analyse, the verical deflection circuit is disregarded and the horizontal deflection/EHT circuit is simplified. In the simplified circuit the EHT generator and the deflection circuit are fully coupled and the east/west modulation and the linearity coil are among other facilities ignored. It is argued for that the simplification does not influence the basic mode of operation of the deflection/EHT circuit and the mode of operation is discussed by means of idealised considerations. A laboratory model of the simplified deflection/EHT circuit has been built and connected in parallel to a 100 HZ television set. By doing this no control circuits are needed in the simplified circuit. Measurements on the simplified defelection/EHT circuit are carried out at three different loads of the DST. The measurements are focused on the voltage and the current waveforms on a circuit level and the influence of the parasitic components is discussed. Besides, a comparison of the waveforms at three different loads is performed and comments and conclusions are presented. A general introduction to the facilities in Saber highlights the primary difference between Spice and Saber with focus on the basic architecture of Saber. The procedure of simulating the simplified deflection/EHT circuit is explained and the demarcations are presented. The simulation is performed with both idealised models of the components and with existing models of the components in Saber. The models of both types of components are shortly presented. The simulated waveforms are in close agreement with the measured waveforms apart from the ringing primary caused by the parasitic components in the DST which are not included in the simulation model. The measuring system, the general measuring process and the data processing used when mapping the power losses in the simplified deflection/EHT circuit are explained. The measurements are performed at the working

  5. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    International Nuclear Information System (INIS)

    Parsapour, Amir; Dehkordi, Behzad Mirzaeian; Moallem, Mehdi

    2015-01-01

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated

  6. Predicting core losses and efficiency of SRM in continuous current mode of operation using improved analytical technique

    Energy Technology Data Exchange (ETDEWEB)

    Parsapour, Amir, E-mail: amirparsapour@gmail.com [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Dehkordi, Behzad Mirzaeian, E-mail: mirzaeian@eng.ui.ac.ir [Department of Electrical Engineering, University of Isfahan, Isfahan (Iran, Islamic Republic of); Moallem, Mehdi, E-mail: moallem@cc.iut.ac.ir [Department of Electrical Engineering, Isfahan University of Technology, Isfahan (Iran, Islamic Republic of)

    2015-03-15

    In applications in which the high torque per ampere at low speed and rated power at high speed are required, the continuous current method is the best solution. However, there is no report on calculating the core loss of SRM in continuous current mode of operation. Efficiency and iron loss calculation which are complex tasks in case of conventional mode of operation is even more involved in continuous current mode of operation. In this paper, the Switched Reluctance Motor (SRM) is modeled using finite element method and core loss and copper loss of SRM in discontinuous and continuous current modes of operation are calculated using improved analytical techniques to include the minor loop losses in continuous current mode of operation. Motor efficiency versus speed in both operation modes is obtained and compared. - Highlights: • Continuous current method for Switched Reluctance Motor (SRM) is explained. • An improved analytical technique is presented for SRM core loss calculation. • SRM losses in discontinuous and continuous current operation modes are presented. • Effect of mutual inductances on SRM performance is investigated.

  7. Power Loss Analysis for Wind Power Grid Integration Based on Weibull Distribution

    Directory of Open Access Journals (Sweden)

    Ahmed Al Ameri

    2017-04-01

    Full Text Available The growth of electrical demand increases the need of renewable energy sources, such as wind energy, to meet that need. Electrical power losses are an important factor when wind farm location and size are selected. The capitalized cost of constant power losses during the life of a wind farm will continue to high levels. During the operation period, a method to determine if the losses meet the requirements of the design is significantly needed. This article presents a Simulink simulation of wind farm integration into the grid; the aim is to achieve a better understanding of wind variation impact on grid losses. The real power losses are set as a function of the annual variation, considering a Weibull distribution. An analytical method has been used to select the size and placement of a wind farm, taking into account active power loss reduction. It proposes a fast linear model estimation to find the optimal capacity of a wind farm based on DC power flow and graph theory. The results show that the analytical approach is capable of predicting the optimal size and location of wind turbines. Furthermore, it revealed that the annual variation of wind speed could have a strong effect on real power loss calculations. In addition to helping to improve utility efficiency, the proposed method can develop specific designs to speeding up integration of wind farms into grids.

  8. Reduction of eddy current losses around bushing holes on the top-plate of a high efficient transformer

    Directory of Open Access Journals (Sweden)

    Mehmet Aytaç ÇINAR

    2017-08-01

    Full Text Available Low voltage winding leads cause local eddy current losses in top-plate of the transformer tank. In this paper, this loss component which also causes local hot spots is investigated. Top-plate design is modified using stainless steel non-magnetic material, around the low voltage bushing holes. Manufacturing issues and cost as well as power losses are considered as main criteria during modification study. Magnetic flux distributions and eddy current losses are analysed and compared for different designs. Comparisons are based on 3D finite element simulations and experimental studies. Obtained results show that, insertion of single I-shaped stainless steel plate reduces eddy current losses around low voltage bushing holes to nearly zero.

  9. POWER LOSSES ASSESSMENT IN TRANSFORMERS AFTER THE NORMATIVE OPERATING PERIOD

    Directory of Open Access Journals (Sweden)

    M. I. Fursanov

    2015-01-01

    Full Text Available The capacity losses values both loading and off-load are topmost parameters characterizing the distribution mains customers’ transformers operating effectiveness. Precise determination of the specified values facilitates substantiated choice of the optimizing procedures. The actuality of the given topic increases owing to the fact that the modern electric grid utilizes plenty of the oil-transformers whose time in commission considerably exceeds the statutory 25 years. Under the conditions of continued operation the power-losses measurement according to the functioning guidelines does not seem always possible.The authors present an improved power-losses assessment technique based on the currently accepted thermal model of the oil-transformer. They indicate the deficiency of the existing technique and substantiate some of the changes in practical application of the mathematical model. The article makes an emphasis on peculiarities of the temperature changes in the oil-transformer and offers a prototype device of open architecture for realizing the improved technique of the power-losses measurement. The paper describes the device design features and functionality options and depicts its sketchy schematic. The authors note the potential of additional to assessing the power-losses volume, transmitting the obtained information to the dispatcher  via  GSM-connection  for  simplification  of  the  transformer  status  monitoring; as well as the capability of integrating the device into the system of the transformer thermal protection. The practical merit and application scope of the obtained results are in development and choice of the optimizing measures to be taken in the distributive electrical grids, e. g. the transformer replacement.

  10. Frequency dependent loss analysis and minimization of system losses in switchmode audio power amplifiers

    DEFF Research Database (Denmark)

    Yamauchi, Akira; Knott, Arnold; Jørgensen, Ivan Harald Holger

    2014-01-01

    In this paper, frequency dependent losses in switch-mode audio power amplifiers are analyzed and a loss model is improved by taking the voltage dependence of the parasitic capacitance of MOSFETs into account. The estimated power losses are compared to the measurement and great accuracy is achieved...

  11. Power fluctuation and power loss of wind turbines due to wind shear and tower shadow

    Institute of Scientific and Technical Information of China (English)

    Binrong WEN; Sha WEI; Kexiang WEI; Wenxian YANG; Zhike PENG; Fulei CHU

    2017-01-01

    The magnitude and stability of power output are two key indices of wind turbines.This study investigates the effects of wind shear and tower shadow on power output in terms of power fluctuation and power loss to estimate the capacity and quality of the power generated by a wind turbine.First,wind speed models,particularly the wind shear model and the tower shadow model,are described in detail.The widely accepted tower shadow model is modified in view of the cone-shaped towers of modem large-scale wind turbines.Power fluctuation and power loss due to wind shear and tower shadow are analyzed by performing theoretical calculations and case analysis within the framework of a modified version of blade element momentum theory.Results indicate that power fluctuation is mainly caused by tower shadow,whereas power loss is primarily induced by wind shear.Under steady wind conditions,power loss can be divided into wind farm loss and rotor loss.Wind farm loss is constant at 3α(3α-1)R2/(8H2).By contrast,rotor loss is strongly influenced by the wind turbine control strategies and wind speed.That is,when the wind speed is measured in a region where a variable-speed controller works,the rotor loss stabilizes around zero,but when the wind speed is measured in a region where the blade pitch controller works,the rotor loss increases as the wind speed intensifies.The results of this study can serve as a reference for accurate power estimation and strategy development to mitigate the fluctuations in aerodynamic loads and power output due to wind shear and tower shadow.

  12. Loss of cooling accident simulation of nuclear power station spent-fuel pool

    Energy Technology Data Exchange (ETDEWEB)

    Lee, M.; Liang, K-S., E-mail: mlee@ess.nthu.edu.tw, E-mail: ksliang_1@hotmail.com [National Tsing Hua Univ., Hsinchu, Taiwan (China); Lin, K-Y., E-mail: syrup760914@gmail.com [Taiwan Power Company, Taiwan (China)

    2014-07-01

    The core melt down accident of Fukushima Nuclear Power Station on March 11th, 2011 alerted nuclear industry that the long term loss of cooling of spent fuel pool may need some attention. The target plant analyzed is the Chinshan Nuclear Power Station of Taiwan Power Company. The 3-Dimensional RELAP5 input deck of the spent fuel pool of the station is built. The results indicate that spent fuel of Chinshan Nuclear Power Station is uncovered at 6.75 days after an accident of loss cooling takes place and cladding temperature rises above 2,200{sup o}F around 8 days. The time is about 13 hours earlier than the results predicted using simple energy balance method. The results also show that the impact of Counter Current Flow Limitation (CCFL) and radiation heat transfer model is marginal. (author)

  13. AC losses in horizontally parallel HTS tapes for possible wireless power transfer applications

    Science.gov (United States)

    Shen, Boyang; Geng, Jianzhao; Zhang, Xiuchang; Fu, Lin; Li, Chao; Zhang, Heng; Dong, Qihuan; Ma, Jun; Gawith, James; Coombs, T. A.

    2017-12-01

    This paper presents the concept of using horizontally parallel HTS tapes with AC loss study, and the investigation on possible wireless power transfer (WPT) applications. An example of three parallel HTS tapes was proposed, whose AC loss study was carried out both from experiment using electrical method; and simulation using 2D H-formulation on the FEM platform of COMSOL Multiphysics. The electromagnetic induction around the three parallel tapes was monitored using COMSOL simulation. The electromagnetic induction and AC losses generated by a conventional three turn coil was simulated as well, and then compared to the case of three parallel tapes with the same AC transport current. The analysis demonstrates that HTS parallel tapes could be potentially used into wireless power transfer systems, which could have lower total AC losses than conventional HTS coils.

  14. Measurement of power loss during electric vehicle charging and discharging

    International Nuclear Information System (INIS)

    Apostolaki-Iosifidou, Elpiniki; Codani, Paul; Kempton, Willett

    2017-01-01

    When charging or discharging electric vehicles, power losses occur in the vehicle and the building systems supplying the vehicle. A new use case for electric vehicles, grid services, has recently begun commercial operation. Vehicles capable of such application, called Grid-Integrated Vehicles, may have use cases with charging and discharging summing up to much more energy transfer than the charging only use case, so measuring and reducing electrical losses is even more important. In this study, the authors experimentally measure and analyze the power losses of a Grid-Integrated Vehicle system, via detailed measurement of the building circuits, power feed components, and of sample electric vehicle components. Under the conditions studied, measured total one-way losses vary from 12% to 36%, so understanding loss factors is important to efficient design and use. Predominant losses occur in the power electronics used for AC-DC conversion. The electronics efficiency is lowest at low power transfer and low state-of-charge, and is lower during discharging than charging. Based on these findings, two engineering design approaches are proposed. First, optimal sizing of charging stations is analyzed. Second, a dispatch algorithm for grid services operating at highest efficiency is developed, showing 7.0% to 9.7% less losses than the simple equal dispatch algorithm. - Highlights: • Grid-to-battery-to-grid comprehensive power loss measurement and analysis. • No previous experimental measurements of Grid-Integrated Vehicle system power loss. • Electric vehicle loss analyzed as a factor of state of charge and charging rate. • Power loss in the building components less than 3%. • Largest losses found in Power Electronics (typical round-trip loss 20%).

  15. Sensitivity Analysis of Core Damage by Loss of Auxiliary Feed Water during the Extended Loss of All AC Power

    Energy Technology Data Exchange (ETDEWEB)

    Jeon, Woo Jae; Chung, Soon Il; Hwang, Su Hyun; Lee, Kyung Jin; Lee, Byung Chul [FNC Tech., Yongin (Korea, Republic of); Yun, Duk Joo; Lee, Seung Chan [Korea Hydro and Nuclear Power Co. Ltd., Daejeon (Korea, Republic of)

    2015-10-15

    In this study, the reactor core damage time for OPR1000 type Nuclear Power Plant (NPP) was analyzed to develop a strategy to handle ELAP and to apply to the EOP. The reactor core damage time in the ELAP condition was calculated according to the time of Auxiliary Feedwater (AFW) loss. Fukushima accident was caused by long hours of Station Black Out (SBO) caused by natural disaster beyond Design Based Accident (DBA) criteria. It led to the reactor core damage. After the accident, the regulatory authorities of each country (Japan, US, EU, IAEA, and etc.) recommended developing the necessary systems and strategies in order to cover up the Extended Loss of All AC Power (ELAP) such as one occurred in the Fukushima accident. And the need of procedure or guideline to cope with ELAP has been raised through the stress test for Wolsong Nuclear Power Plant unit 1. Current Emergency Operating Procedures (EOP) used in domestic nuclear power plant are seemed to be insufficient to cope with ELAP. Therefore, it has been required to be improved. As the result, the time of AFW loss in the ELAP condition influences greatly on core damage time.

  16. Lower hybrid wave edge power loss quantification on the Alcator C-Mod tokamak

    Science.gov (United States)

    Faust, I. C.; Brunner, D.; LaBombard, B.; Parker, R. R.; Terry, J. L.; Whyte, D. G.; Baek, S. G.; Edlund, E.; Hubbard, A. E.; Hughes, J. W.; Kuang, A. Q.; Reinke, M. L.; Shiraiwa, S.; Wallace, G. M.; Walk, J. R.

    2016-05-01

    For the first time, the power deposition of lower hybrid RF waves into the edge plasma of a diverted tokamak has been systematically quantified. Edge deposition represents a parasitic loss of power that can greatly impact the use and efficiency of Lower Hybrid Current Drive (LHCD) at reactor-relevant densities. Through the use of a unique set of fast time resolution edge diagnostics, including innovative fast-thermocouples, an extensive set of Langmuir probes, and a Lyα ionization camera, the toroidal, poloidal, and radial structure of the power deposition has been simultaneously determined. Power modulation was used to directly isolate the RF effects due to the prompt ( t Radiofrequency (LHRF) power. LHRF power was found to absorb more strongly in the edge at higher densities. It is found that a majority of this edge-deposited power is promptly conducted to the divertor. This correlates with the loss of current drive efficiency at high density previously observed on Alcator C-Mod, and displaying characteristics that contrast with the local RF edge absorption seen on other tokamaks. Measurements of ionization in the active divertor show dramatic changes due to LHRF power, implying that divertor region can be a key for the LHRF edge power deposition physics. These observations support the existence of a loss mechanism near the edge for LHRF at high density ( n e > 1.0 × 10 20 (m-3)). Results will be shown addressing the distribution of power within the SOL, including the toroidal symmetry and radial distribution. These characteristics are important for deducing the cause of the reduced LHCD efficiency at high density and motivate the tailoring of wave propagation to minimize SOL interaction, for example, through the use of high-field-side launch.

  17. AC losses in multilayer power transmission cables comprised of YBCO tapes

    International Nuclear Information System (INIS)

    Noji, H.

    2011-01-01

    I calculate AC properties in YBCO cable by an electric circuit model. The optimal helical pitches are determined by the calculation. The layer's current distribution is uniform on the optimal helical pitches. The calculation is useful as a first approximation of AC losses. AC losses in multilayer power transmission cables can be reduced by adjusting the helical winding pitch of each layer to make the layer's current distribution uniform. The optimum helical pitch can be estimated using an electric circuit (EC) model based on the expression that calculates the losses in the superconducting tapes composing the cable. It is known that the losses in a monolayer cable depend on the cable parameters (i.e., the gap between neighboring tapes, number of tapes N, diameter of the cable former and width of the tape). However, regarding Amemiya et al.'s measurement on the losses in monolayer cables, the numerical results of the losses calculated using the Norris formula for an isolated thin strip N times are close to the experimental results. Then, to determine the losses in a three-layer cable that Mukoyama et al. have reported, the losses are calculated by the EC model based on the Norris formula. The helical pitch of each layer is adjusted to make the layer's current distribution uniform in the cable reported by Mukoyama et al. The optimum helical pitches are calculated using the condition where the standard deviation of the layer currents is minimum, and the losses of the cable at the optimum helical pitches are calculated at 1 kA rms . By comparing the results of these calculations with the previously measured results, it was found that the mean error of the calculated values relative to the measured values is 23.7%, which indicates that the calculation using the EC model is useful as a first approximation.

  18. Comparative Analysis of Semiconductor Power Losses of Galvanically Isolated Quasi-Z-Source and Full-Bridge Boost DC-DC Converters

    Directory of Open Access Journals (Sweden)

    Kosenko Roman

    2015-07-01

    Full Text Available This paper compares semiconductor losses of the galvanically isolated quasi-Z-source converter and full-bridge boost DC-DC converter with active clamping circuit. Operation principle of both converters is described. Short design guidelines are provided as well. Results of steady state analysis are used to calculate semiconductor power losses for both converters. Analytical expressions are derived for all types of semiconductor power losses present in these converters. The theoretical results were verified by means of numerical simulation performed in the PSIM simulation software. Its add-on module “Thermal module” was used to estimate semiconductor power losses using the datasheet parameters of the selected semiconductor devices. Results of calculations and simulation study were obtained for four operating points with different input voltage and constant input current to compare performance of the converters in renewable applications, like photovoltaic, where input voltage and power can vary significantly. Power loss breakdown is detailed and its dependence on the converter output power is analyzed. Recommendations are given for the use of the converter topologies in applications with low input voltage and relatively high input current.

  19. Self-field AC losses and critical currents in multi-tube Ag-Bi-2223 conductors

    Energy Technology Data Exchange (ETDEWEB)

    Ciszek, M; Ashworth, S P; Campbell, A M [IRC in Superconductivity, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); James, M P; Glowacki, B A [IRC in Superconductivity, University of Cambridge, Madingley Road, Cambridge CB3 0HE (United Kingdom); Department of Materials Science and Metallurgy, University of Cambridge, Pembroke Street, Cambridge CB2 3QZ (United Kingdom); Garre, R; Conti, S [Centro Ricerche Europa Metalli, Fornaci di Barga, LU (Italy)

    1996-05-01

    The purpose of this work was to investigate the influence of different technological treatments of silver sheathed Bi-2223 tapes on the critical current density and the AC transport losses. The tapes were produced using the 'tube-in-tube' technique, by including a silver rod in the centre of the superconducting powder during packing of the silver tube. The aim of the process is to increase the silver to superconductor surface area and thus also the alignment at the centre of the conductor ceramic core. AC transport losses were measured by means of an electrical method using sinusoidally varying currents in the frequency range 30-180 Hz. In this range the power losses are hysteretic. The measured variation in losses from those predicted by a critical state model is attributed to the complex geometry of superconducting regions existing in these tapes. (author)

  20. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    International Nuclear Information System (INIS)

    Perkins, R. J.; Bell, R. E.; Bertelli, N.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; LeBlanc, B. P.; Kramer, G. J.; Maingi, R.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Scotti, F.; Taylor, G.; Wilson, J. R.; Ahn, J-W.; Gray, T. K.; Green, D. L.; McLean, A.

    2014-01-01

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  1. Towards identifying the mechanisms underlying field-aligned edge-loss of HHFW power on NSTX

    Energy Technology Data Exchange (ETDEWEB)

    Perkins, R. J.; Bell, R. E.; Bertelli, N.; Diallo, A.; Gerhardt, S.; Hosea, J. C.; Jaworski, M. A.; LeBlanc, B. P.; Kramer, G. J.; Maingi, R.; Phillips, C. K.; Podestà, M.; Roquemore, L.; Scotti, F.; Taylor, G.; Wilson, J. R. [Princeton Plasma Physics Laboratory, Princeton, NJ (United States); Ahn, J-W.; Gray, T. K.; Green, D. L.; McLean, A. [Oak Ridge National Laboratory, Oak Ridge, TN (United States); and others

    2014-02-12

    Fast-wave heating will be a major heating scheme on ITER, as it can heat ions directly and is relatively unaffected by the large machine size unlike neutral beams. However, fast-wave interactions with the plasma edge can lead to deleterious effects such as, in the case of the high-harmonic fast-wave (HHFW) system on NSTX, large losses of fast-wave power in the scrape off layer (SOL) under certain conditions. In such scenarios, a large fraction of the lost HHFW power is deposited on the upper and lower divertors in bright spiral shapes. The responsible mechanism(s) has not yet been identified but may include fast-wave propagation in the scrape off layer, parametric decay instability, and RF currents driven by the antenna reactive fields. Understanding and mitigating these losses is important not only for improving the heating and current-drive on NSTX-Upgrade but also for understanding fast-wave propagation across the SOL in any fast-wave system. This talk summarizes experimental results demonstrating that the flow of lost HHFW power to the divertor regions largely follows the open SOL magnetic field lines. This lost power flux is relatively large close to both the antenna and the last closed flux surface with a reduced level in between, so the loss mechanism cannot be localized to the antenna. At the same time, significant losses also occur along field lines connected to the inboard edge of the bottom antenna plate. The power lost within the spirals is roughly estimated, showing that these field-aligned losses to the divertor are significant but may not account for the total HHFW loss. To elucidate the role of the onset layer for perpendicular fast-wave propagation with regards to fast-wave propagation in the SOL, a cylindrical cold-plasma model is being developed. This model, in addition to advanced RF codes such as TORIC and AORSA, is aimed at identifying the underlying mechanism(s) behind these SOL losses, to minimize their effects in NSTX-U, and to predict

  2. Lithium-ion backup batteries for coping extended loss of AC power (ELAP)

    International Nuclear Information System (INIS)

    Chang, Choong-koo

    2017-01-01

    Per NRC Regulations Title 10, Code of Federal Regulations (CFR) 50.63 'Loss of all alternating current power' all Korean nuclear power plants have a coping capability for SBO conditions for a limited time ranging from approximately eight (8) to sixteen (16) hours. The 125V DC systems are designed for eight (8) hours range except Class 1E channel A and B 125V DC system of which duty cycle is 2 hours in APR1400. The strategies proposed by this paper for coping extended loss of AC power (ELAP) involve a three-phase approach. In the first extend class 1E batteries' backup time until 24 hours. Then augment class 1E batteries with Lithium-ion batteries by 72 hours from the event initiation. In addition, obtain additional capability and redundancy from off-site equipment until power systems are restored or commissioned. (author)

  3. Losses of off-site power at U.S. nuclear power plants -- through 1995. Final report

    International Nuclear Information System (INIS)

    Wyckoff, H.

    1996-04-01

    This report provides a database and summary analysis of losses of off-site power at US nuclear generating units. It includes the 16 years 1980 through 1995. This is the twelfth update of this database and analysis. During 1994 there were no losses of all off-site power and in 1995 only two short losses. Both the short term and long term US loss of all off-site power experience is extremely favorable. The frequency of losing all off-site power is an important input to many nuclear plant safety assessments. The industry's loss of all off-site power experience that is set forth in this report can provide perspective to plant specific probabilistic safety assessments

  4. Fiscal 1999 research report. Development of ultralow- loss power device technology (Survey on next-generation practical power semiconductor devices); 1999 nendo choteisonshitsu denryoku soshi gijutsu kaihatsu seika hokokusho. Jisedai power handotai device jitsuyoka chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-03-01

    This research proposes the clear developmental policy and target for 'Development project of ultralow-loss power device technology' through the research on power electronics or advanced power semiconductor devices as key technology of conversion loss reduction for various power applications and power supply systems. Main research issues are as follows. A bidirectional current switch using P-MOS FETs is promising as an ace of power system interconnection control equipment. IEGT as MOS gate high-power device will be substituted for GTO gradually. SiC devices will play the leading part of low- loss power devices for inverters of power converters, power systems of electric vehicles, Shinkansen and maglev railways, power systems of information and communication systems, and DC power systems. Size and cost reduction of low-noise soft switching as application technology of power devices are possible by using active circuits. Development of high- efficiency low-noise compact inexpensive inverters is an important issue. Countermeasures against various losses of inverters are also described. (NEDO)

  5. Losses at magnetic nulls in pulsed-power transmission line systems

    International Nuclear Information System (INIS)

    Mendel, C.W. Jr.; Pointon, T.D.; Savage, M.E.; Seidel, D.B.; Magne, I.; Vezinet, R.

    2006-01-01

    Pulsed-power systems operating in the terawatt regime must deal with large electron flows in vacuum transmission lines. In most parts of these transmission lines the electrons are constrained by the self-magnetic field to flow parallel to the conductors. In very low impedance systems, such as those used to drive Z-pinch radiation sources, the currents from multiple transmission lines are added together. This addition necessarily involves magnetic nulls that connect the positive and negative electrodes. The resultant local loss of magnetic insulation results in electron losses at the anode in the vicinity of the nulls. The lost current due to the magnetic null might or might not be appreciable. In some cases the lost current due to the null is not large, but is spatially localized, and may create a gas and plasma release from the anode that can lead to an excessive loss, and possibly to catastrophic damage to the hardware. In this paper we describe an analytic model that uses one geometric parameter (aside from straightforward hardware size measurements) that determines the loss to the anode, and the extent of the loss region when the driving source and load are known. The parameter can be calculated in terms of the magnetic field in the region of the null calculated when no electron flow is present. The model is compared to some experimental data, and to simulations of several different hardware geometries, including some cases with multiple nulls, and unbalanced feeds

  6. Pumping slots: impedances and power losses

    Energy Technology Data Exchange (ETDEWEB)

    Kurennoy, S [Maryland Univ., College Park, MD (United States). Dept. of Physics

    1996-08-01

    Contributions of pumping slots to the beam coupling impedances and power losses in a B-factory ring are considered. While their leading contribution is to the inductive impedance, for high-intensity machines with short bunches like e{sup +}e{sup -} B-factories the real part of the impedance and related loss factors are also important. Using an analytical approach we calculate the coupling impedances and loss factors due to slots in a ring with an arbitrary cross section of the vacuum chamber. Effects of the slot tilt on the beam impedance are also considered, and restrictions on the tilt angle are derived from limitations on the impedance increase. The power leakage through the slots is discussed briefly. The results are applied to the KEK B-factory. (author)

  7. Calculation and Analysis of Permanent Magnet Eddy Current Loss Fault with Magnet Segmentation

    Directory of Open Access Journals (Sweden)

    Bing Li

    2016-01-01

    Full Text Available This paper investigates the problem of calculating and analyzing the effect of the permanent magnet eddy current loss fault due to magnet segmentation. Taking an interior permanent magnet synchronous motor with inverter supplied as an example, the rated power of motor was 2.2 kW. Three-dimensional finite-element model was firstly established based on finite-element software. Then, the model mesh and boundary conditions were handled specially; permanent magnet eddy current loss fault was calculated and analyzed theoretically with magnet segmentation from space harmonic and time harmonic, respectively. Finally, calculation results were compared and explained. A useful conclusion for permanent magnet synchronous motor design has been obtained.

  8. Model Predictive Current Control for High-Power Grid-Connected Converters with Output LCL Filter

    DEFF Research Database (Denmark)

    Delpino, Hernan Anres Miranda; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    A model predictive control strategy for a highpower, grid connected 3-level neutral clamped point converter is presented. Power losses constraints set a limit on commutation losses so reduced switching frequency is required, thus producing low frequency current harmonics. To reduce these harmonics...

  9. AC power losses in Bi-2223/Ag HTS tapes

    International Nuclear Information System (INIS)

    Savvides, N.; Reilly, D.; Mueller, K.-H.; Herrmann, J.

    1998-01-01

    Full text: We report measurements at 77 K of the transport ac losses of Bi-2223/Ag composite tapes. The investigated tapes vary from single filament to multifilament construction and include both conventional tapes and other conductor shapes with twisted filaments. The self-field ac losses were determined at 77 K and 60 Hz as a function of ac current amplitude (0 - 100 A). We observe different behaviour among tapes depending on their quality and strain history. For 'good' virgin tapes the experimental data are well described by the Norris equations for the dependence of power loss P on the amplitude I m of the transport current. The data of good monofilament tapes are fitted to the Norris equation P ∼ I m n for an elliptical cross section (ie. n = 3) and the data of good multifilament tapes are fitted to the Norris equation for a rectangular strip (ie. n = 4). Many specimens, however, show a range of behaviour with lower values of n. Based on our work on the effect of strain on the dc transport properties of tapes, we carried out detailed investigations of the effect of controlled applied bend strain on the ac loss. Our results show that irreversible damage to superconducting filaments (ie. cracks) cause the ac loss to rise and n to decrease with increasing strain. In addition, applied strains much greater than the irreversible strain limit cause the ac loss to increase by several orders of magnitude and become ohmic in character with n = 2. Theoretical work is in progress to model the observed behaviour

  10. ac loss and dc critical current densities of Nb3Sn tapes by the solid state diffusion process

    International Nuclear Information System (INIS)

    Suenaga, M.; Klamut, C.; Bussiere, J.F.

    1976-01-01

    The effects of metallurgical processing on 60 Hz ac losses and dc critical currents in Nb 3 Sn tapes fabricated by the solid state diffusion technique were investigated. An addition of Al to the Cu--Sn alloy for the matrix resulted in large reduction in the ac losses of Nb 3 Sn tapes, but the highest linear critical current densities were observed in Nb 3 Sn tapes produced with a Nb-1 wt percent Zr core in a Cu-13 wt percent Sn matrix. Values of the losses and the critical currents in these tapes can meet the present requirements for the ac superconducting power cables

  11. Power balance and loss mechanism analysis in RF transmit coil arrays.

    Science.gov (United States)

    Kuehne, Andre; Goluch, Sigrun; Waxmann, Patrick; Seifert, Frank; Ittermann, Bernd; Moser, Ewald; Laistler, Elmar

    2015-10-01

    To establish a framework for transmit array power balance calculations based on power correlation matrices to accurately quantify the loss contributions from different mechanisms such as coupling, lumped components, and radiation. Starting from Poynting's theorem, power correlation matrices are derived for all terms in the power balance, which is formulated as a matrix equation. Finite-difference time-domain simulations of two 7 T eight-channel head array coils at 297.2 MHz are used to verify the theoretical considerations and demonstrate their application. Care is taken to accurately incorporate all loss mechanisms. The power balance for static B1 phase shims as well as two-dimensional spatially selective transmit SENSE pulses is shown. The simulated power balance shows an excellent agreement with theory, with a maximum power imbalance of less than 0.11%. Power loss contributions from the different loss mechanisms vary significantly between the investigated setups, and depending on the excitation mode imposed on the coil. The presented approach enables a straightforward loss evaluation for an arbitrary excitation of transmit coil arrays. Worst-case power imbalance and losses are calculated in a straightforward manner. This allows for deeper insight into transmit array loss mechanisms, incorporation of radiated power components in specific absorption rate calculations and verification of electromagnetic simulations. © 2014 Wiley Periodicals, Inc.

  12. EVALUATING DEGREE OF ACTIVE POWER LOSSES REDUCTION IN THE ELECTRIC POWER LINES WITH REACTIVE POWER COMPENSATION

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2016-01-01

    Full Text Available The paper considers evaluation procedure for the degree of active power losses reduction in the power transmission lines under 1 kV and 6–10 kV of the systems of electric power supply of industrial enterprises with compensating installations mounted at the side of the customer. The capacitor installations conform to the applied voltage level and factor in dielectric losses in the capacitors. The voltage at the compensating device terminal changes from 0.95 to 1.05 of the capacitors nominal voltage. The study did not account for reactive power losses in the line, nor did it for its charge capacity, conditioned by relative shortness of the cable lines generally operating in the mains of industrial enterprises. For this reason, the quantities of reactive power being consumed and generated by the transmission line are negligible and do not significantly affect the reactive power flux. The researchers obtain functional relations that allow estimating the degree of power loss reduction in the transmission line factoring in its explicit initial data. They perform mathematical analysis of the obtained functional relations and study the function by means of derivatives. The function extremum points are found as well as the intervals of its increment and decrement. A graphical research of the obtained functional relation is performed. It is ascertained that reduction of the active power losses is contingent on the line and the capacitor-installation engineering factors, the electrical energy consumer reactive load value as well as the voltage applied to the capacitor installation. The functional relations presented in the article can be employed in scoping calculation necessary for decision making on the reactive power compensation in systems of the industrial facilities electric power supply. Their account will allow a more accurate estimate of technical and economic effect of the capacitor bank installation in the electrical mains under 1 kV and 6

  13. Power loss analysis in altered tooth-sum spur gearing

    Directory of Open Access Journals (Sweden)

    Sachidananda H. K.

    2018-01-01

    Full Text Available The main cause of power loss or dissipation of heat in case of meshed gears is due to friction existing between gear tooth mesh and is a major concern in low rotational speed gears, whereas in case of high operating speed the power loss taking place due to compression of air-lubricant mixture (churning losses and windage losses due to aerodynamic trial of air lubricant mixture which controls the total efficiency needs to be considered. Therefore, in order to improve mechanical efficiency it is necessary for gear designer during gear tooth optimization to consider these energy losses. In this research paper the power loss analysis for a tooth-sum of 100 altered by ±4% operating between a specified center distance is considered. The results show that negative altered tooth-sum gearing performs better as compared to standard and positive altered tooth-sum gearing.

  14. Thermo-stimulated current and dielectric loss in composite materials

    International Nuclear Information System (INIS)

    Nishijima, S.; Hagihara, T.; Okada, T.

    1986-01-01

    Thermo-stimulated current and dielectric loss measurements have been performed on five kinds of commercially available composite materials in order to study the electric properties of composite materials at low temperatures. Thermo-stimulated current measurements have been made on the composite materials in which the matrix quality was changed intentionally. The changes in the matrices were introduced by gamma irradiation or different curing conditions. Thermo-stimulated current and dielectric loss measurements revealed the number and the molecular weight of dipolar molecules. The different features of thermo-stimulated current and dielectric losses were determined for different composite materials. The gamma irradiation and the curing conditions especially affect the thermo-stimulated current features. The changes in macroscopic mechanical properties reflect those of thermo-stimulated current. It was found that the change in quality and/or degradation of the composite materials could be detected by means of thermo-stimulated current and/or dielectric loss measurements

  15. Assessment of environmental impact of HVDC power lines in terms of corona currents

    International Nuclear Information System (INIS)

    Tikhodeev, N.N.

    1997-01-01

    Corona loss measurements were made on a HVDC power transmission line to evaluate current density. Ion currents were obtained from unipolar and bipolar 400 to 1000 kV DC test lines. A numerical solution was proposed for assessing the maximum current density of unipolar corona currents near the lines. A larger ground clearance of line conductors was proposed as being the most effective way of lowering the current density. 11 refs., 2 tabs., 4 figs

  16. Collection and evaluation of complete and partial losses of off-site power at nuclear power plants

    International Nuclear Information System (INIS)

    Battle, R.E.

    1985-02-01

    Events involving loss of off-site power that have occurred at nuclear power plants through 1983 are described and categorized as complete or partial losses. The events were identified as plant-centered or grid-related failures. In addition, the causes of the failures were classified as weather, human error, design error, or hardware failure. The plant-centered failures were usually of shorter duration than the weather-related grid failures. For this reason, the weather-related events were reviewed in detail. Design features that may be important factors affecting off-site power system reliability were tabulated for most of the operating nuclear power plants. The tabulated information was provided to NRC for a statistical analysis to determine the importance of these design features for losses of off-site power. The frequency of losses of off-site power versus duration was estimated for three time periods. The frequency of loss of off-site power was estimated to be 0.09/reactor-year based on industry-wide data for the years 1959 through 1983

  17. Coordinated Power Dispatch of a PMSG based Wind Farm for Output Power Maximizing Considering the Wake Effect and Losses

    DEFF Research Database (Denmark)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    2016-01-01

    The energy loss in a wind farm (WF) caused by wake interaction between wind turbines (WTs) is quite high, which can be reduced by proper active power dispatch. The electrical loss inside a WF by improper active power and reactive power dispatch is also considerable. In this paper, a coordinated...... active power and reactive power dispatch strategy is proposed for a Permanent magnet synchronous generator (PMSG) based WF, in order to maximize the total output power by reducing the wake effect and losses inside the devices of the WF, including the copper loss and iron loss of PMSGs, losses inside...

  18. Minimisation of Power loss from partially shaded solar cell arrays

    Energy Technology Data Exchange (ETDEWEB)

    Maine, Tony; Bell, John [Queensland University of Technology, Brisbane (Australia). Built Environment Engineering; Martin, Stewart [University of South Australia, Mawson Lakes Campus, SA (Australia). School of Electrical and Information Engineering

    2008-07-01

    In conventional wiring schemes the output from a partially shaded solar cell array drops rapidly to that of the fully shaded array even when only a small fraction is shaded. In this paper circuit simulation has been used to show that by dynamically reconfiguring the array, the power losses due to shading can be significantly reduced. Reconfiguration is achieved by using switching microcircuits with on-chip photo detectors to determine which parts of the array are in shade. The currents from the shaded and unshaded sections of the array are separated and then connected in parallel to a maximum power point tracker. It is shown that by using this reconfiguration that the power output from a partially shaded array can be increased by at least 100% compared with that from a conventional series connected array over a range of shading conditions. (orig.)

  19. Measuring ac losses in superconducting cables using a resonant circuit:Resonant current experiment (RESCUE)

    DEFF Research Database (Denmark)

    Däumling, Manfred; Olsen, Søren Krüger; Rasmussen, Carsten

    1998-01-01

    be recorded using, for example, a digital oscilloscope. The amplitude decay of the periodic voltage or current accurately reflects the power loss in the system. It consists of two components-an ohmic purely exponential one (from leads, contacts, etc.), and a nonexponential component originating from......A simple way to obtain true ac losses with a resonant circuit containing a superconductor, using the decay of the circuit current, is described. For the measurement a capacitor is short circuited with a superconducting cable. Energy in the circuit is provided by either charging up the capacitors...... with a certain voltage, or letting a de flow in the superconductor. When the oscillations are started-either by opening a switch in case a de is flowing or by closing a switch to connect the charged capacitors with the superconductor-the current (via a Rogowski coil) or the voltage on the capacitor can...

  20. Radiation losses and global power balance of JT-60 plasmas

    International Nuclear Information System (INIS)

    Nishitani, T.; Itami, K.; Nagashima, K.; Tsuji, S.; Hosogane, N.; Yoshida, H.; Ando, T.; Kubo, H.; Takeuchi, H.

    1990-01-01

    The radiation losses and the global power balance for Ohmic and neutral beam heated plasmas have been investigated in different JT-60 configurations. Discharges with a TiC coated molybdenum wall and with a graphite wall, with limiter, outer and lower X-point configurations have been studied by bolometric measurements, thermocouples and an infrared TV camera. In neutral beam heated outer X-point discharges with a TiC coated molybdenum first wall, the radiation loss of the main plasma was very low (10% of the absorbed power). The radiation loss due to oxygen was dominant in this case. On the contrary, in discharges with TiC coated molybdenum limiters the radiation loss was very high (>60% of the absorbed power). In the discharges with a graphite wall the radiated power from the main plasma was 20-25% for both limiter and lower X-point configurations. In lower X-point discharges the main contributor to the radiation loss was oxygen, whereas in limiter discharges the loss due to carbon was equal to the loss due to oxygen. The radiation loss from the lower X-point divertor increased with increasing electron density of the main plasma. (author). 33 refs, 14 figs, 1 tab

  1. Evolution of beam losses after a power cut of the SR7 AC supply

    CERN Document Server

    GOMEZ ALONSO, A

    2009-01-01

    Magnet failures in the LHC could lead to equipment damage if the energy stored in the accelerator was not discharged properly. The Machine Protection Systems (MPS) ensure this proper discharge and knowledge about the evolution of losses in case of failure is needed to evaluate the adequacy of the protection. A power cut of the AC supply in SR7 would lead to a simultaneous current decay in three normal conducting circuits. The evolution of the losses after such failure is slow, with a loss time constant of more than 100 ms both at 450 GeV and 7 TeV, and in both cases the damage level is not reached before 45 ms. This leaves sufficient time for the MPS to ensure redundant protection. A similar scenario would be expected for a power cut at SR3.

  2. Calorimetric Measuring Systems for Characterizing High Frequency Power Losses in Power Electronic Components and Systems

    DEFF Research Database (Denmark)

    Blaabjerg, Frede; Pedersen, John Kim; Ritchie, Andrew Ewen

    2002-01-01

    High frequency power losses in power electronic components and systems are very difficult to measure. The same applies to the efficiency of high-efficiency systems and components. An important method to measure losses with high accuracy is the calorimetric measuring systems. This paper describes...... to calibrate such systems are proposed and different applications of the system are given. Two practical examples end the description of the research. It is concluded that such systems have a relative long time-constant but they are accurate and useful for precise power loss measurement....

  3. A 1–2 GHz high linearity transformer-feedback power-to-current LNA

    NARCIS (Netherlands)

    Li, X.; Serdijn, W.A.; Woestenburg, B.E.M.; Bij de Vaate, J.G.

    2009-01-01

    This paper demonstrates that a double-loop transformer-feedback power-to-current low noise amplifier, to be implemented in a 0.2 lm GaAs p-HEMT IC process, is able to obtain a noise figure less than 0.8 dB, an input return loss less than -12 dB, a flat voltage-to-current signal transfer of 180 mS,

  4. Evaluation of Control and Protection System for Loss of Electrical Power Supply System of Water-Cooling Nuclear Power Plant

    International Nuclear Information System (INIS)

    Suhaemi, Tjipta; Djen Djen; Setyono; Jambiar, Riswan; Rozali, Bang; Setyo P, Dwi; Tjahyono, Hendro

    2000-01-01

    Evaluation of control and protection system for loss of electrical power supply system of water-cooled nuclear power plant has been done. The loss of electrical power supply. The accident covered the loss of external electrical load and loss of ac power to the station auxiliaries. It is analysed by studying and observing the mechanism of electrical power system and mechanism of related control and protection system. The are two condition used in the evaluation i e without turbine trip and with turbine trip. From the evaluation it is concluded that the control and protection system can handled the failure caused by the loss of electrical power system

  5. Structure-based capacitance modeling and power loss analysis for the latest high-performance slant field-plate trench MOSFET

    Science.gov (United States)

    Kobayashi, Kenya; Sudo, Masaki; Omura, Ichiro

    2018-04-01

    Field-plate trench MOSFETs (FP-MOSFETs), with the features of ultralow on-resistance and very low gate–drain charge, are currently the mainstream of high-performance applications and their advancement is continuing as low-voltage silicon power devices. However, owing to their structure, their output capacitance (C oss), which leads to main power loss, remains to be a problem, especially in megahertz switching. In this study, we propose a structure-based capacitance model of FP-MOSFETs for calculating power loss easily under various conditions. Appropriate equations were modeled for C oss curves as three divided components. Output charge (Q oss) and stored energy (E oss) that were calculated using the model corresponded well to technology computer-aided design (TCAD) simulation, and we validated the accuracy of the model quantitatively. In the power loss analysis of FP-MOSFETs, turn-off loss was sufficiently suppressed, however, mainly Q oss loss increased depending on switching frequency. This analysis reveals that Q oss may become a significant issue in next-generation high-efficiency FP-MOSFETs.

  6. Quantitative Prediction of Power Loss for Damaged Photovoltaic Modules Using Electroluminescence

    Directory of Open Access Journals (Sweden)

    Timo Kropp

    2018-05-01

    Full Text Available Electroluminescence (EL is a powerful tool for the qualitative mapping of the electronic properties of solar modules, where electronic and electrical defects are easily detected. However, a direct quantitative prediction of electrical module performance purely based on electroluminescence images has yet to be accomplished. Our novel approach, called “EL power prediction of modules” (ELMO as presented here, used just two electroluminescence images to predict the electrical loss of mechanically damaged modules when compared to their original (data sheet power. First, using this method, two EL images taken at different excitation currents were converted into locally resolved (relative series resistance images. From the known, total applied voltage to the module, we were then able to calculate absolute series resistance values and the real distribution of voltages and currents. Then, we reconstructed the complete current/voltage curve of the damaged module. We experimentally validated and confirmed the simulation model via the characterization of a commercially available photovoltaic module containing 60 multicrystalline silicon cells, which were mechanically damaged by hail. Deviation between the directly measured and predicted current/voltage curve was less than 4.3% at the maximum power point. For multiple modules of the same type, the level of error dropped below 1% by calibrating the simulation. We approximated the ideality factor from a module with a known current/voltage curve and then expand the application to modules of the same type. In addition to yielding series resistance mapping, our new ELMO method was also capable of yielding parallel resistance mapping. We analyzed the electrical properties of a commercially available module, containing 72 monocrystalline high-efficiency back contact solar cells, which suffered from potential induced degradation. For this module, we predicted electrical performance with an accuracy of better

  7. The losses at power grid caused by small nonlinear loads

    Directory of Open Access Journals (Sweden)

    Stevanović Dejan

    2013-01-01

    Full Text Available The difference between registered active power and spent unregistered power represents the losses at power grid. This paper treats problems related to losses caused by nonlinear loads connected to the power grid. In recent years the load profile of power consumers turned from energy-waster linear to energysaver but non-linear loads. The main cause of the losses appears due to the lack of adequate measurement equipment. Namely, common household power meters register only active energy, while power meters for industrial application register reactive energy as well. This approach does not follow the change of the enduser profile. Tendency of improving energy efficiency brought wide use of switching mode regulators and replace old incandescent light bulb with new energy saving lamps (CFL - compact fluorescent lamp, LED bulb. Therefore, the number of non-linear load drastically increased. Registering only active component of power at consumer’s side does not depict the real profile of the consumption. Therefore, in this paper we analyse and quantify the effects of nonlinear loads at power losses. As a result we suggest an efficient method for measuring the distortion component of power. The method relays on low-cost upgrade of commercial electronic power meters. The presented results of measurements on small non-linear loads confirm the proposed technique. Besides, they prove the importance of measuring all components of apparent power and justified their use in billing policy. The implemented set-up is based on power meter manufactured by EWG of Niš. [Projekat Ministarstva nauke Republike Srbije, br. TR32004

  8. Power loss separation in Fe-based composite materials

    Energy Technology Data Exchange (ETDEWEB)

    Kollar, Peter, E-mail: peter.kollar@upjs.sk [Institute of Physics, Faculty of Science, Pavol Jozef Safarik University, Park Angelinum 9, 04154 Kosice (Slovakia); Bircakova, Zuzana; Fuezer, Jan [Institute of Physics, Faculty of Science, Pavol Jozef Safarik University, Park Angelinum 9, 04154 Kosice (Slovakia); Bures, Radovan; Faberova, Maria [Institute of Materials Research, Slovak Academy of Sciences, Watsonova 47, 04001 Kosice (Slovakia)

    2013-02-15

    The frequency dependence of total losses measured in the frequency range from dc to 1 kHz of two Fe-based soft magnetic composites (prepared by compaction of an ASC 100.29 iron powder mixture with 10 vol% of commercial thermoset resin and of a Somaloy{sup Registered-Sign} 700 powder) was analyzed. We found out that hysteresis losses (per volume unit) are higher for the composite with lower volume concentration of iron particles (i.e. mixture of iron with resin) and consequently weaker magnetic interaction between particles. On the other hand, higher specific resistivity of the sample with lower magnetic fraction causes lower contribution of eddy current losses to the total losses. A linear dependence of the total energy losses on frequency was observed and from them the contribution of excess losses was obtained. The detailed study of the excess losses resulted in an explanation of the frequency dependence of these losses in composite materials. - Highlights: Black-Right-Pointing-Pointer It was observed that excess losses in SMC depend on the frequency linearly. Black-Right-Pointing-Pointer Two components of eddy current losses (inter- and intra-particle) were analyzed. Black-Right-Pointing-Pointer Larger amount of insulator causes the eddy current inside ferromagnetic particles.

  9. Rotating gravity currents. Part 1. Energy loss theory

    Science.gov (United States)

    Martin, J. R.; Lane-Serff, G. F.

    2005-01-01

    A comprehensive energy loss theory for gravity currents in rotating rectangular channels is presented. The model is an extension of the non-rotating energy loss theory of Benjamin (J. Fluid Mech. vol. 31, 1968, p. 209) and the steady-state dissipationless theory of rotating gravity currents of Hacker (PhD thesis, 1996). The theory assumes the fluid is inviscid, there is no shear within the current, and the Boussinesq approximation is made. Dissipation is introduced using a simple method. A head loss term is introduced into the Bernoulli equation and it is assumed that the energy loss is uniform across the stream. Conservation of momentum, volume flux and potential vorticity between upstream and downstream locations is then considered. By allowing for energy dissipation, results are obtained for channels of arbitrary depth and width (relative to the current). The results match those from earlier workers in the two limits of (i) zero rotation (but including dissipation) and (ii) zero dissipation (but including rotation). Three types of flow are identified as the effect of rotation increases, characterized in terms of the location of the outcropping interface between the gravity current and the ambient fluid on the channel boundaries. The parameters for transitions between these cases are quantified, as is the detailed behaviour of the flow in all cases. In particular, the speed of the current can be predicted for any given channel depth and width. As the channel depth increases, the predicted Froude number tends to surd 2, as for non-rotating flows.

  10. Power transformer additional load losses separation procedure

    Directory of Open Access Journals (Sweden)

    Kostić Miloje M.

    2011-01-01

    Full Text Available The proposed procedure is based on the fact that total transformer losses (PLL1,n, determined by short circuit test, can be separated into two components: the eddy current losses in the windings (PEC1,n and stray flux losses (PSL1,n in iron parts of construction as well as in the transformer tank walls. The total additional load losses, PLLd1 and PLLdh, are determined by short circuit test results, conducted at rated frequency (f1 and at increased harmonic frequency (fh=h*f1. Using so obtained total additional load losses, PLLd1 and PLLdh, which can be expressed in the form PLLdh=PEC1,n*h2 + PSL1,n*h, the corresponding rate additional load losses values PEC1,n and PSL1,n are derived. At the end, for given load with predefined high harmonics content, (Ih/I1n, relative to rated current, the total additional load losses value ΣPLLdh > PLLd1, is found. In such a way all harmonics up to hmax are taken into account.

  11. Alternating current loss calculation in a high-TC superconducting transmission cable considering the magnetic field distribution

    International Nuclear Information System (INIS)

    Noji, H; Haji, K; Hamada, T

    2003-01-01

    We have calculated the alternating current (ac) losses of a 114 MVA high-T C superconducting (HTS) transmission cable using an electric-circuit (EC) model. The HTS cable is fabricated by Tokyo Electric Power Company and Sumitomo Electric Industries, Ltd. The EC model is comprised of a resistive part and an inductive part. The resistive part is obtained by the approximated Norris equation for a HTS tape. The Norris equation indicates hysteresis losses due to self-fields. The inductive part has two components, i.e. inductances related to axial fields and those related to circumferential fields. The layer currents and applied fields of each layer were calculated by the EC model. By using both values, the ac losses of the one-phase HTS cable were obtained by calculation considering the self-field, the axial field and the circumferential field of the HTS tape. The measured ac loss transporting 1 kA rms is 0.7 W m -1 ph -1 , which is equal to the calculation. The distribution of each layer loss resembles in shape the distribution of the circumferential field in each layer, which indicates that the circumferential fields strongly influence the ac losses of the HTS cable

  12. Energy losses of superconducting power transmission cables in the grid

    DEFF Research Database (Denmark)

    Østergaard, Jacob; Okholm, Jan; Lomholt, Karin

    2001-01-01

    One of the obvious motives for development of superconducting power transmission cables is reduction of transmission losses. Loss components in superconducting cables as well as in conventional cables have been examined. These losses are used for calculating the total energy losses of conventional...... as well as superconducting cables when they are placed in the electric power transmission network. It is concluded that high load connections are necessary to obtain energy saving by the use of HTSC cables. For selected high load connections, an energy saving of 40% is expected. It is shown...

  13. Energy losses in switches

    International Nuclear Information System (INIS)

    Martin, T.H.; Seamen, J.F.; Jobe, D.O.

    1993-01-01

    The authors experiments show energy losses between 2 and 10 times that of the resistive time predictions. The experiments used hydrogen, helium, air, nitrogen, SF 6 polyethylene, and water for the switching dielectric. Previously underestimated switch losses have caused over predicting the accelerator outputs. Accurate estimation of these losses is now necessary for new high-efficiency pulsed power devices where the switching losses constitute the major portion of the total energy loss. They found that the switch energy losses scale as (V peak I peak ) 1.1846 . When using this scaling, the energy losses in any of the tested dielectrics are almost the same. This relationship is valid for several orders of magnitude and suggested a theoretical basis for these results. Currents up to .65 MA, with voltages to 3 MV were applied to various gaps during these experiments. The authors data and the developed theory indicates that the switch power loss continues for a much longer time than the resistive time, with peak power loss generally occurring at peak current in a ranging discharge instead of the early current time. All of the experiments were circuit code modeled after developing a new switch loss version based on the theory. The circuit code predicts switch energy loss and peak currents as a function of time. During analysis of the data they noticed slight constant offsets between the theory and data that depended on the dielectric. They modified the plasma conductivity for each tested dielectric to lessen this offset

  14. Recurrent pregnancy loss: current perspectives

    Directory of Open Access Journals (Sweden)

    El Hachem H

    2017-05-01

    Full Text Available Hady El Hachem,1,2 Vincent Crepaux,3 Pascale May-Panloup,4 Philippe Descamps,3 Guillaume Legendre,3 Pierre-Emmanuel Bouet3 1Department of Reproductive Medicine, Ovo Clinic, Montréal, QC, Canada; 2Department of Obstetrics and Gynecology, University of Montreal, Montréal, QC, Canada; 3Department of Obstetrics and Gynecology, Angers University Hopsital, Angers, France; 4Department of Reproductive Biology, Angers University Hospital, Angers, France Abstract: Recurrent pregnancy loss is an important reproductive health issue, affecting 2%–5% of couples. Common established causes include uterine anomalies, antiphospholipid syndrome, hormonal and metabolic disorders, and cytogenetic abnormalities. Other etiologies have been proposed but are still considered controversial, such as chronic endometritis, inherited thrombophilias, luteal phase deficiency, and high sperm DNA fragmentation levels. Over the years, evidence-based treatments such as surgical correction of uterine anomalies or aspirin and heparin for antiphospholipid syndrome have improved the outcomes for couples with recurrent pregnancy loss. However, almost half of the cases remain unexplained and are empirically treated using progesterone supplementation, anticoagulation, and/or immunomodulatory treatments. Regardless of the cause, the long-term prognosis of couples with recurrent pregnancy loss is good, and most eventually achieve a healthy live birth. However, multiple pregnancy losses can have a significant psychological toll on affected couples, and many efforts are being made to improve treatments and decrease the time needed to achieve a successful pregnancy. This article reviews the established and controversial etiologies, and the recommended therapeutic strategies, with a special focus on unexplained recurrent pregnancy losses and the empiric treatments used nowadays. It also discusses the current role of preimplantation genetic testing in the management of recurrent pregnancy

  15. Enhanced GSA-Based Optimization for Minimization of Power Losses in Power System

    Directory of Open Access Journals (Sweden)

    Gonggui Chen

    2015-01-01

    Full Text Available Gravitational Search Algorithm (GSA is a heuristic method based on Newton’s law of gravitational attraction and law of motion. In this paper, to further improve the optimization performance of GSA, the memory characteristic of Particle Swarm Optimization (PSO is employed in GSAPSO for searching a better solution. Besides, to testify the prominent strength of GSAPSO, GSA, PSO, and GSAPSO are applied for the solution of optimal reactive power dispatch (ORPD of power system. Conventionally, ORPD is defined as a problem of minimizing the total active power transmission losses by setting control variables while satisfying numerous constraints. Therefore ORPD is a complicated mixed integer nonlinear optimization problem including many constraints. IEEE14-bus, IEEE30-bus, and IEEE57-bus test power systems are used to implement this study, respectively. The obtained results of simulation experiments using GSAPSO method, especially the power loss reduction rates, are compared to those yielded by the other modern artificial intelligence-based techniques including the conventional GSA and PSO methods. The results presented in this paper reveal the potential and effectiveness of the proposed method for solving ORPD problem of power system.

  16. Investigation of extra power loss sharing among photovoltaic inverters caused by reactive power management in distribution networks

    DEFF Research Database (Denmark)

    Demirok, Erhan; Sera, Dezso; Teodorescu, Remus

    2014-01-01

    load and power loss on the feeders and individual inverters. Simplified energy loss evaluation is carried out here by using analytical average loss modeling of 2-level full bridge inverter coupled with network load flow analysis simulating one month period. The study shows that whatever Q control......Grid-connected photovoltaic (PV) inverters tailored with reactive power management feature can support the grid voltage especially when the voltage fluctuates near its admissible limits. Although Q control allows reducing the grid voltage elevation along the distribution feeder, it brings extra...... is selected, extra power loss is not a substantial amount to take into consideration. Similarly, loss difference among the inverters located at the various points is negligible....

  17. Study on Frequency Dependency of ON-Resistance and Pulse-Loss Calculation of MOSFETs for Switch Mode Power Supply

    Science.gov (United States)

    Yamamura, Hideho; Sato, Ryohei; Iwata, Yoshiharu

    Global efforts toward energy conservation, increasing data centers, and the increasing use of IT equipments are leading to a demand in reduced power consumption of equipments, and power efficiency improvement of power supply units is becoming a necessity. MOSFETs are widely used for their low ON-resistances. Power efficiency is designed using time-domain circuit simulators, except for transformer copper-loss, which has frequency dependency which is calculated separately using methods based on skin and proximity effects. As semiconductor technology reduces the ON-resistance of MOSFETs, frequency dependency due to the skin effect or proximity effect is anticipated. In this study, ON-resistance of MOSFETs are measured and frequency dependency is confirmed. Power loss against rectangular current pulse is calculated. The calculation method for transformer copper-loss is expanded to MOSFETs. A frequency function for the resistance model is newly developed and parametric calculation is enabled. Acceleration of calculation is enabled by eliminating summation terms. Using this method, it is shown that the frequency dependent component of the measured MOSFETs increases the dissipation from 11% to 32% at a switching frequency of 100kHz. From above, this paper points out the importance of the frequency dependency of MOSFETs' ON-resistance, provides means of calculating its pulse losses, and improves loss calculation accuracy of SMPSs.

  18. Experimental study of current loss and plasma formation in the Z machine post-hole convolute

    Directory of Open Access Journals (Sweden)

    M. R. Gomez

    2017-01-01

    Full Text Available The Z pulsed-power generator at Sandia National Laboratories drives high energy density physics experiments with load currents of up to 26 MA. Z utilizes a double post-hole convolute to combine the current from four parallel magnetically insulated transmission lines into a single transmission line just upstream of the load. Current loss is observed in most experiments and is traditionally attributed to inefficient convolute performance. The apparent loss current varies substantially for z-pinch loads with different inductance histories; however, a similar convolute impedance history is observed for all load types. This paper details direct spectroscopic measurements of plasma density, temperature, and apparent and actual plasma closure velocities within the convolute. Spectral measurements indicate a correlation between impedance collapse and plasma formation in the convolute. Absorption features in the spectra show the convolute plasma consists primarily of hydrogen, which likely forms from desorbed electrode contaminant species such as H_{2}O, H_{2}, and hydrocarbons. Plasma densities increase from 1×10^{16}  cm^{−3} (level of detectability just before peak current to over 1×10^{17}  cm^{−3} at stagnation (tens of ns later. The density seems to be highest near the cathode surface, with an apparent cathode to anode plasma velocity in the range of 35–50  cm/μs. Similar plasma conditions and convolute impedance histories are observed in experiments with high and low losses, suggesting that losses are driven largely by load dynamics, which determine the voltage on the convolute.

  19. A.C. losses in current-carrying superconductors

    International Nuclear Information System (INIS)

    Reuver, J.L. de.

    1985-01-01

    The feasibility of superconductors for alternating current use depends on successful reduction of losses. Moreover, the demand for large field amplitudes is a stimulation for investigating the nature of a.c. losses (e.g. in the set of poloidal coils in a TOKAMAK). In this thesis, measurements are performed at a.c. superconductivity. Attention is given to various external field conditions as well as to self-field instability. Measurements are performed on different types of wires. A type of wire is searched for with both low losses and a good stabilization under self-field conditions. (G.J.P.)

  20. Investigation of Power Losses of Two-Stage Two-Phase Converter with Two-Phase Motor

    Directory of Open Access Journals (Sweden)

    Michal Prazenica

    2011-01-01

    Full Text Available The paper deals with determination of losses of two-stage power electronic system with two-phase variable orthogonal output. The simulation is focused on the investigation of losses in the converter during one period in steady-state operation. Modeling and simulation of two matrix converters with R-L load is shown in the paper. The simulation results confirm a very good time-waveform of the phase current and the system seems to be suitable for low-cost application in automotive/aerospace industries and in application with high frequency voltage sources.

  1. Loss Minimizing Operation of Doubly Fed Induction Generator Based Wind Generation Systems Considering Reactive Power Provision

    DEFF Research Database (Denmark)

    Baohua, Zhang; Hu, Weihao; Chen, Zhe

    2014-01-01

    The paper deals with control techniques for minimizing the operating loss of doubly fed induction generator based wind generation systems when providing reactive power. The proposed method achieves its goal through controlling the rotor side q-axis current in the synchronous reference frame...

  2. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    2017-01-01

    that must be spent immediately in cable and installation costs, and the future reduced revenues due to power losses. The latter goal has not been addressed in previous work. We present a Mixed-Integer Linear Programming approach to optimize the routing using both exact and math-heuristic methods....... In the power losses computation, wind scenarios are handled eciently as part of the preprocessing, resulting in a MIP model of only slightly larger size. A library of real-life instances is introduced and made publicly available for benchmarking. Computational results on this testbed show the viability of our...

  3. Effect of distributed generation installation on power loss using genetic algorithm method

    Science.gov (United States)

    Hasibuan, A.; Masri, S.; Othman, W. A. F. W. B.

    2018-02-01

    Injection of the generator distributed in the distribution network can affect the power system significantly. The effect that occurs depends on the allocation of DG on each part of the distribution network. Implementation of this approach has been made to the IEEE 30 bus standard and shows the optimum location and size of the DG which shows a decrease in power losses in the system. This paper aims to show the impact of distributed generation on the distribution system losses. The main purpose of installing DG on a distribution system is to reduce power losses on the power system.Some problems in power systems that can be solved with the installation of DG, one of which will be explored in the use of DG in this study is to reduce the power loss in the transmission line. Simulation results from case studies on the IEEE 30 bus standard system show that the system power loss decreased from 5.7781 MW to 1,5757 MW or just 27,27%. The simulated DG is injected to the bus with the lowest voltage drop on the bus number 8.

  4. Direct current power delivery system and method

    Science.gov (United States)

    Zhang, Di; Garces, Luis Jose; Dai, Jian; Lai, Rixin

    2016-09-06

    A power transmission system includes a first unit for carrying out the steps of receiving high voltage direct current (HVDC) power from an HVDC power line, generating an alternating current (AC) component indicative of a status of the first unit, and adding the AC component to the HVDC power line. Further, the power transmission system includes a second unit for carrying out the steps of generating a direct current (DC) voltage to transfer the HVDC power on the HVDC power line, wherein the HVDC power line is coupled between the first unit and the second unit, detecting a presence or an absence of the added AC component in the HVDC power line, and determining the status of the first unit based on the added AC component.

  5. Modelling the power losses in the ferromagnetic materials

    Directory of Open Access Journals (Sweden)

    Detka Kalina

    2017-07-01

    Full Text Available In this paper, the problem of describing power losses in ferromagnetic materials is considered. The limitations of Steinmetz formula are shown and a new analytical description of losses in a considered material is proposed. The correctness of the developed description is demonstrated experimentally by comparing the results of calculation with the catalogue characteristics for different ferromagnetic materials.

  6. Alternating current losses of a 10 metre long low loss superconducting cable conductor determined from phase sensitive measurements

    DEFF Research Database (Denmark)

    Olsen, Søren Krüger; Kühle (fratrådt), Anders Van Der Aa; Træholt, Chresten

    1999-01-01

    The ac loss of a superconducting cable conductor carrying an ac current is small. Therefore the ratio between the inductive (out-of-phase) and the resistive (in-phase) voltages over the conductor is correspondingly high. In vectorial representations this results in phase angles between the current......-in amplifiers can be exploited. In this paper we present the results from ac-loss measurements on a low loss 10 metre long high temperature superconducting cable conductor using such a correction scheme. Measurements were carried out with and without a compensation circuit that could reduce-the inductive...... voltage. The 1 mu V cm(-1) critical current of the conductor was 3240 A at 77 K. At an rms current of 2 kA (50 Hz) the ac loss was derived to be 0.6 +/- 0.15 W m(-1). This is, to the best of our knowledge, the lowest value of ac loss of a high temperature superconducting cable conductor reported so far...

  7. Power loss problems in EXTRAP coil systems

    International Nuclear Information System (INIS)

    Lehnert, B.

    1977-02-01

    The Ohmic power loss in the coils of external ring traps is minimized with respect to the thermonuclear power production. In the case of the DT-reaction this leads to dimensions and power densities being relevant to full-scale reactors. Not only superconducting or refrigerated coil windings can thus be used, but also hot-coil systems which are operated at several hundred degrees centrigrade and form part of a steam cycle and power extraction system. For hot coils the problems of void formation and tritium regeneration have to be further examined. The high beta value leads to moderately large coil stresses. Finally, replacement and repair become simplified by the present coil geometry. (Auth.)

  8. Power Loss Minimization for Transformers Connected in Parallel with Taps Based on Power Chargeability Balance

    Directory of Open Access Journals (Sweden)

    Álvaro Jaramillo-Duque

    2018-02-01

    Full Text Available In this paper, a model and solution approach for minimizing internal power losses in Transformers Connected in Parallel (TCP with tap-changers is proposed. The model is based on power chargeability balance and seeks to keep the load voltage within an admissible range. For achieving this, tap positions are adjusted in such a way that all TCP are set in similar/same power chargeability. The main contribution of this paper is the inclusion of several construction features (rated voltage, rated power, voltage ratio, short-circuit impedance and tap steps in the minimization of power losses in TCP that are not included in previous works. A Genetic Algorithm (GA is used for solving the proposed model that is a system of nonlinear equations with discrete decision variables. The GA scans different sets for tap positions with the aim of balancing the power supplied by each transformer to the load. For this purpose, a fitness function is used for minimizing two conditions: The first condition consists on the mismatching between power chargeability for each transformer and a desired chargeability; and the second condition is the mismatching between the nominal load voltage and the load voltage obtained by changing the tap positions. The proposed method is generalized for any given number of TCP and was implemented for three TCP, demonstrating that the power losses are minimized and the load voltage remains within an admissible range.

  9. Identification of some additional loss components in high-power low-voltage permanent magnet generators

    Energy Technology Data Exchange (ETDEWEB)

    Hamalainen, H.

    2013-11-01

    Permanent magnet generators (PMG) represent the cutting edge technology in modern wind mills. The efficiency remains high (over 90%) at partial loads. To improve the machine efficiency even further, every aspect of machine losses has to be analyzed. Additional losses are often given as a certain percentage without providing any detailed information about the actual calculation process; meanwhile, there are many design-dependent losses that have an effect on the total amount of additional losses and that have to be taken into consideration. Additional losses are most often eddy current losses in different parts of the machine. These losses are usually difficult to calculate in the design process. In this doctoral thesis, some additional losses are identified and modeled. Further, suggestions on how to minimize the losses are given. Iron losses can differ significantly between the measured no-load values and the loss values under load. In addition, with embedded magnet rotors, the quadrature-axis armature reaction adds losses to the stator iron by manipulating the harmonic content of the flux. It was, therefore, re-evaluated that in salient pole machines, to minimize the losses and the loss difference between the no-load and load operation, the flux density has to be kept below 1.5 T in the stator yoke, which is the traditional guideline for machine designers. Eddy current losses may occur in the end-winding area and in the support structure of the machine, that is, in the finger plate and the clamping ring. With construction steel, these losses account for 0.08% of the input power of the machine. These losses can be reduced almost to zero by using nonmagnetic stainless steel. In addition, the machine housing may be subjected to eddy current losses if the flux density exceeds 1.5 T in the stator yoke. Winding losses can rise rapidly when high frequencies and 10-15 mm high conductors are used. In general, minimizing the winding losses is simple. For example, it can be

  10. Current amplification models of sensorineurall and conductive hearing loss

    OpenAIRE

    Ostojić, Sanja; Mikić, Branka; Mirić, Danica

    2012-01-01

    The main function of a hearing aid is to improve auditory and language abilities of hearing impaired users. The amplification model has to be adapted according to age, degree and type of hearing loss. The goal of this paper is to analyze the current amplification models of sensorineural and conductive hearing loss which can provide a high quality of speech perception and sounds at any degree of hearing loss. The BAHA is a surgically implantable system for treatment of conductive hearing loss ...

  11. Managing peri-implant bone loss: current understanding.

    Science.gov (United States)

    Aljateeli, Manar; Fu, Jia-Hui; Wang, Hom-Lay

    2012-05-01

    With the improved macro- and micro-designs, dental implants enjoy a high survival rate. However, peri-implant bone loss has recently emerged to be the focus of implant therapy. As such, researchers and clinicians are in need of finding predictable techniques to treat peri-implant bone loss and stop its progression. Literature search on the currently available treatment modalities was performed and a brief description of each modality was provided. Numerous techniques have been proposed and none has been shown to be superior and effective in managing peri-implant bone loss. This may be because of the complex of etiological factors acting on the implant-supported prosthesis hence the treatment approach has to be individually tailored. Due to the lack of high-level clinical evidence on the management of peri-implant bone loss, the authors, through a literature review, attempt to suggest a decision tree or guideline, based on sound periodontal surgical principles, to aid clinicians in managing peri-implantitis associated bone loss. © 2011 Wiley Periodicals, Inc.

  12. Mitigating Space Weather Impacts on the Power Grid in Real-Time: Applying 3-D EarthScope Magnetotelluric Data to Forecasting Reactive Power Loss in Power Transformers

    Science.gov (United States)

    Schultz, A.; Bonner, L. R., IV

    2017-12-01

    Current efforts to assess risk to the power grid from geomagnetic disturbances (GMDs) that result in geomagnetically induced currents (GICs) seek to identify potential "hotspots," based on statistical models of GMD storm scenarios and power distribution grounding models that assume that the electrical conductivity of the Earth's crust and mantle varies only with depth. The NSF-supported EarthScope Magnetotelluric (MT) Program operated by Oregon State University has mapped 3-D ground electrical conductivity structure across more than half of the continental US. MT data, the naturally occurring time variations in the Earth's vector electric and magnetic fields at ground level, are used to determine the MT impedance tensor for each site (the ratio of horizontal vector electric and magnetic fields at ground level expressed as a complex-valued frequency domain quantity). The impedance provides information on the 3-D electrical conductivity structure of the Earth's crust and mantle. We demonstrate that use of 3-D ground conductivity information significantly improves the fidelity of GIC predictions over existing 1-D approaches. We project real-time magnetic field data streams from US Geological Survey magnetic observatories into a set of linear filters that employ the impedance data and that generate estimates of ground level electric fields at the locations of MT stations. The resulting ground electric fields are projected to and integrated along the path of power transmission lines. This serves as inputs to power flow models that represent the power transmission grid, yielding a time-varying set of quasi-real-time estimates of reactive power loss at the power transformers that are critical infrastructure for power distribution. We demonstrate that peak reactive power loss and hence peak risk for transformer damage from GICs does not necessarily occur during peak GMD storm times, but rather depends on the time-evolution of the polarization of the GMD's inducing fields

  13. A battery-powered high-current power supply for superconductors

    CERN Document Server

    Wake, M; Suda, K

    2002-01-01

    Since superconductors do not require voltages, a high-current power supply could run with low power if the voltage is sufficiently reduced. Even a battery-powered power supply could give as much as 2,000A for a superconductor. To demonstrate this hypothesis, a battery-powered 2,000A power supply was constructed. It uses an IGBT chopper and Schottky diode together with a specially arranged transformer to produce a high current with low voltage. Testing of 2,000A operation was performed for about 1.5 hr using 10 car batteries. Charging time for this operation was 8 hr. Ramping control was smooth and caused no trouble. Although the IGBT frequency ripple of 16.6 kHz was easily removed using a passive filter, spike noise remained in the output voltage. This ripple did not cause any trouble in operating a pancake-type inductive superconducting load. (author)

  14. A Power Supply System with ZVS and Current-Doubler Features for Hybrid Renewable Energy Conversion

    Directory of Open Access Journals (Sweden)

    Jye-Chau Su

    2013-09-01

    Full Text Available In this paper, a power supply system for hybrid renewable energy conversion is proposed, which can process PV (photovoltaic power and wind-turbine energy simultaneously for step-down voltage and high current applications. It is a dual-input converter and mainly contains a PV energy source, a wind turbine energy source, a zero-voltage-switching (ZVS forward converter, and a current-doubler rectifier. The proposed power supply system has the following advantages: (1 PV-arrays and wind-energy sources can alternatively deliver power to the load during climate or season alteration; (2 maximum power point tracking (MPPT can be accomplished for both different kinds of renewable-energy sources; (3 ZVS and synchronous rectification techniques for the active switches of the forward converter are embedded so as to reduce switching and conducting losses; and (4 electricity isolation is naturally obtained. To achieve an optimally dynamic response and to increase control flexibility, a digital signal processor (DSP is investigated and presented to implement MPPT algorithm and power regulating scheme. Finally, a 240 W prototype power supply system with ZVS and current-doubler features to deal with PV power and wind energy is built and implemented. Experimental results are presented to verify the performance and the feasibility of the proposed power supply system.

  15. Alternating current losses of a 10 metre long low loss superconducting cable conductor determined from phase sensitive measurements

    International Nuclear Information System (INIS)

    Krueger Olsen, S.; Kuehle, A.; Traeholt, C.; C Rasmussen, C.; Toennesen, O.; Daeumling, M.; Rasmussen, C.N.; Willen, D.W.A.

    1999-01-01

    The ac loss of a superconducting cable conductor carrying an ac current is small. Therefore the ratio between the inductive (out-of-phase) and the resistive (in-phase) voltages over the conductor is correspondingly high. In vectorial representations this results in phase angles between the current and the voltage over the cable close to 90 degrees. This has the effect that the loss cannot be derived directly using most commercial lock-in amplifiers due to their limited absolute accuracy. However, by using two lock-in amplifiers and an appropriate correction scheme the high relative accuracy of such lock-in amplifiers can be exploited. In this paper we present the results from ac-loss measurements on a low loss 10 metre long high temperature superconducting cable conductor using such a correction scheme. Measurements were carried out with and without a compensation circuit that could reduce the inductive voltage. The 1 μV cm -1 critical current of the conductor was 3240 A at 77 K. At an rms current of 2 kA (50 Hz) the ac loss was derived to be 0.6±0.15 W m -1 . This is, to the best of our knowledge, the lowest value of ac loss of a high temperature superconducting cable conductor reported so far at these high currents. (author)

  16. Power Loss Calculation and Thermal Modelling for a Three Phase Inverter Drive System

    Directory of Open Access Journals (Sweden)

    Z. Zhou

    2005-12-01

    Full Text Available Power losses calculation and thermal modelling for a three-phase inverter power system is presented in this paper. Aiming a long real time thermal simulation, an accurate average power losses calculation based on PWM reconstruction technique is proposed. For carrying out the thermal simulation, a compact thermal model for a three-phase inverter power module is built. The thermal interference of adjacent heat sources is analysed using 3D thermal simulation. The proposed model can provide accurate power losses with a large simulation time-step and suitable for a long real time thermal simulation for a three phase inverter drive system for hybrid vehicle applications.

  17. Numerical study of electron-leakage power loss in a tri-plate transmission line

    International Nuclear Information System (INIS)

    Barker, R.J.; Goldstein, S.A.

    1982-01-01

    Numerical simulations have been conducted using NRL's DIODE2D computer code to model the steady-state behavior of electron flow in a radial diode and in its adjacent tri-plate transmission line (TTL). Particular attention was paid to the magnitude of the electron current flowing from the cathode to the anode surface in the TTL. A quantitative value for this effective power loss is given. The electron current is restricted mainly to the transition region in the TTL into which there is seepage of the B/sub z/ that is imposed in the diode gap. This finding highlights the importance of that region to diode designers

  18. Transport current ac losses and current-voltage curves of multifilamentary Bi-2223/Ag tape with artificial defects

    International Nuclear Information System (INIS)

    Polak, M.; Jansak, L.

    2000-01-01

    We experimentally studied the effects of a single artificial defect and a linear array of artificial defects on I-V curves, critical currents and transport current ac losses of 55 filament untwisted Bi-2223/Ag tapes. The artificial defect was a small hole drilled into the tape. The reduction in the critical current measured on a 1 cm long section due to one hole of diameter 0.9 mm was 33% and that due to a linear array of seven similar holes was 62%. The slopes of the I-V curves, n, measured in this section were 33, 16 and 5.8 in the original sample, in the sample with one defect and the sample with seven defects, respectively. Both I c and the slope reduction were smaller if the distance between the potential taps was increased. The transport current ac losses at 50 Hz and I rms = 10 A in the sample with one defect measured in a 1 cm long section were practically the same as those in the original sample (4.1x10 -4 W m -1 ), but they increased by 83% in the sample with a linear array of seven defects. The measured increase in losses per unit length was the smaller, the larger the distance between the potential taps. A comparison between the measured and calculated losses revealed that a formal application of the Norris equations for loss calculations in samples with local defects leads to an overestimation of the ac losses. A procedure for the calculation of transport current losses in samples with local defects based on the Norris model is proposed and verified. (author)

  19. Analytical Modeling Of The Steinmetz Coefficient For Single-Phase Transformer Eddy Current Loss Prediction

    Directory of Open Access Journals (Sweden)

    T. Aly Saandy

    2015-08-01

    Full Text Available Abstract This article presents to an analytical calculation methodology of the Steinmetz coefficient applied to the prediction of Eddy current loss in a single-phase transformer. Based on the electrical circuit theory the active power consumed by the core is expressed analytically in function of the electrical parameters as resistivity and the geometrical dimensions of the core. The proposed modeling approach is established with the duality parallel series. The required coefficient is identified from the empirical Steinmetz data based on the experimented active power expression. To verify the relevance of the model validations both by simulations with two in two different frequencies and measurements were carried out. The obtained results are in good agreement with the theoretical approach and the practical results.

  20. A Hybrid Optimization Method for Reactive Power and Voltage Control Considering Power Loss Minimization

    DEFF Research Database (Denmark)

    Liu, Chengxi; Qin, Nan; Bak, Claus Leth

    2015-01-01

    This paper proposes a hybrid optimization method to optimally control the voltage and reactive power with minimum power loss in transmission grid. This approach is used for the Danish automatic voltage control (AVC) system which is typically a non-linear non-convex problem mixed with both...

  1. Active power compensator of the current harmonics based on the instantaneous power theory

    Directory of Open Access Journals (Sweden)

    Marian GAICEANU

    2005-12-01

    Full Text Available The quality of the electrical current becomes a major concern. The proliferation of the power electronic converters, which are used extensively to control electrical apparatus in industrial and commercial applications (dc and ac variable speed motor drives, induction furnaces, power line conditioners, and industrial power supplies, is at the origin of the AC current distribution network pollution and the reactive power demand. These power electronic converters typically draw non-sinusoidal currents from the utility, causing interference with adjacent sensitive loads and limit the utilization of the available electrical supply. The quality of the electrical current thus becomes a significant concern for the distributors of energy and their customers. Recent progress as regards technology of the power electronics brings a capacity of compensation and correction of the harmonic distortion generated by the nonlinear loads. In this paper a parallel active filter prototype capable of reducing the total harmonic distortion in the supply for most current source or adjustable speed drive type loads is presented. A 33 kVA active power filter was developed for harmonic and reactive power compensation based on the instantaneous power theory. The active filter configuration requires the measurement of both the load and filter currents. Experimental results from a prototype active power filter confirm the suitability of the proposed approach. The actual 33kVA prototype converter has been built and tested in the SIEI S.p.A. (Italy laboratory under the Marie Curie Post Doctoral research. The active power compensator is controlled by a high performance DSP platform, resulting in the following active filter features: source current reduction up to the 25th harmonic, 10% THD achievable for current source type loads, efficiency above 97%, does not cause resonance with other loads, operation in the presence of unbalanced loads, reactive power and harmonics

  2. Complete Loss and Thermal Model of Power Semiconductors Including Device Rating Information

    DEFF Research Database (Denmark)

    Ma, Ke; Bahman, Amir Sajjad; Beczkowski, Szymon

    2015-01-01

    Thermal loading of power devices are closely related to the reliability performance of the whole converter system. The electrical loading and device rating are both important factors that determine the loss and thermal behaviors of power semiconductor devices. In the existing loss and thermal...

  3. Power quality issues current harmonics

    CERN Document Server

    Mikkili, Suresh

    2015-01-01

    Power Quality Issues: Current Harmonics provides solutions for the mitigation of power quality problems related to harmonics. Focusing on active power filters (APFs) due to their excellent harmonic and reactive power compensation in two-wire (single phase), three-wire (three-phase without neutral), and four-wire (three-phase with neutral) AC power networks with nonlinear loads, the text:Introduces the APF technology, describing various APF configurations and offering guidelines for the selection of APFs for specific application considerationsCompares shunt active filter (SHAF) control strategi

  4. Power loss measurement of implantable wireless power transfer components using a Peltier device balance calorimeter

    International Nuclear Information System (INIS)

    Leung, Ho Yan; Budgett, David M; Taberner, Andrew; Hu, Patrick

    2014-01-01

    Determining heat losses in power transfer components operating at high frequencies for implantable inductive power transfer systems is important for assessing whether the heat dissipated by the component is acceptable for implantation and medical use. However, this is a challenge at high frequencies and voltages due to limitations in electronic instrumentation. Calorimetric methods of power measurement are immune to the effects of high frequencies and voltages; hence, the measurement is independent of the electrical characteristics of the system. Calorimeters have been widely used to measure the losses of high power electrical components (>50 W), however it is more difficult to perform on low power components. This paper presents a novel power measurement method for components dissipating anywhere between 0.2 W and 1 W of power based on a heat balance calorimeter that uses a Peltier device as a balance sensor. The proposed balance calorimeter has a single test accuracy of ±0.042 W. The experimental results revealed that there was up to 35% difference between the power measurements obtained with electrical methods and the proposed calorimeter. (paper)

  5. Loss Performance Analysis of an Isolated Power Supply for Ultrafast Tracking Converters

    DEFF Research Database (Denmark)

    Nguyen-Duy, Khiem; Knott, Arnold; Andersen, Michael A. E.

    2014-01-01

    This paper presents the loss performance analysis of an isolated power supply that is designed for ultra-fast tracking converters. The results of the analysis provide insights into the operation of the proposed power supply, how each physical component contributes to the total loss, and how its...

  6. Loss of preferred power events in German BWRs and PWRs

    International Nuclear Information System (INIS)

    Frisch, W.

    1984-01-01

    This chapter examines the variety of courses which the loss of auxiliary power case may take in different plants, depending on the initiation of the event, the switching to the alternate auxiliary power supply and the automatic start-up sequences of auxiliaries (e.g. feedwater pumps, condensate pumps) after a short term interruption of auxiliary power. Topics considered include main station transformer failure in a boiling water reactor (BWR), main plant features, event description, evaluation of the event, deviations from expected behavior, operator actions, a comparison with start-up tests and other events, a comparison with postcalculations, and auxiliary transformer failure in a pressurized water reactor (PWR). Loss of preferred (or auxiliary) power events are standard design cases taken into account in the design of many reactor and plant systems

  7. An analysis of power sector system losses in Bangladesh and Pakistan

    International Nuclear Information System (INIS)

    Choudhari, W.

    1995-01-01

    In this article, the author discusses the analysis of power sector system losses in both the countries which are similar in nature. The design and construction of major power plants, grid substations and transmission lines are constructed on the same pattern. The generation system loss under transmission must not exceed the limit and any loss above this limit could safely be taken as pilferage or theft of energy. The author is of the opinion that socio-economic conditions prevailing in both countries. The author is not in a position to analyse or comment on the causes of non-technical system loss in Pakistan, but he feels that some of the causes could also equally be applicable. (A.B.)

  8. Reactive power compensation and loss reduction in large industrial enterprises

    Energy Technology Data Exchange (ETDEWEB)

    Jovanovic, S; Gajic, B; Mijailovic, S [Institute Nikola Tesla, Beograd (Yugoslavia)

    1991-12-01

    This paper considers the reactive power compensation and the active power and energy loss reduction of large radial power networks in the Serbian mine and smelting industry. It gives an efficient optimization procedure for positioning and sizing capacitors in large industrial systems integrated with a simple network analysis method. (Author).

  9. Transport ac loss in a rectangular thin strip with power-law E(J) relation

    International Nuclear Information System (INIS)

    Li, Shuo; Chen, Du-Xing; Fan, Yu; Fang, Jin

    2015-01-01

    Highlights: • Transport ac loss in a thin strip with power-law E(J) is systematically computed. • The scaled results can be accurately used for strips with any critical current and frequency. • Experiments may be unambiguously compared with modeling results at a critical frequency. - Abstract: Transport ac losses of a rectangular thin strip obeying relation E/E c =(J/J c ) n with a fixed critical current I c and n=5,10,20,30, and 40 are accurately computed at a fixed frequency f as functions of the current amplitude I m . The results may be interpolated and scaled to those at any values of I c ,f, and 5⩽n⩽40. Normalized in the same way as that in Norris’ analytical formula derived from the critical-state model and converting f to a critical frequency f c , the modeling results may be better compared with the Norris formula and experimental data. A complete set of calculated modeling data are given with necessary formulas to be easily used by experimentalists in any particular case

  10. Analysis of loss of offsite power events reported in nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Volkanovski, Andrija, E-mail: Andrija.VOLKANOVSKI@ec.europa.eu [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Ballesteros Avila, Antonio; Peinador Veira, Miguel [European Commission, Joint Research Centre, Institute for Energy and Transport, P.O. Box 2, NL-1755 ZG Petten (Netherlands); Kančev, Duško [Kernkraftwerk Goesgen-Daeniken AG, CH-4658 Daeniken (Switzerland); Maqua, Michael [Gesellschaft für Anlagen-und-Reaktorsicherheit (GRS) gGmbH, Schwertnergasse 1, 50667 Köln (Germany); Stephan, Jean-Luc [Institut de Radioprotection et de Sûreté Nucléaire (IRSN), BP 17 – 92262 Fontenay-aux-Roses Cedex (France)

    2016-10-15

    Highlights: • Loss of offsite power events were identified in four databases. • Engineering analysis of relevant events was done. • The dominant root cause for LOOP are human failures. • Improved maintenance procedures can decrease the number of LOOP events. - Abstract: This paper presents the results of analysis of the loss of offsite power events (LOOP) in four databases of operational events. The screened databases include: the Gesellschaft für Anlagen und Reaktorsicherheit mbH (GRS) and Institut de Radioprotection et de Sûreté Nucléaire (IRSN) databases, the IAEA International Reporting System for Operating Experience (IRS) and the U.S. Licensee Event Reports (LER). In total 228 relevant loss of offsite power events were identified in the IRSN database, 190 in the GRS database, 120 in U.S. LER and 52 in IRS database. Identified events were classified in predefined categories. Obtained results show that the largest percentage of LOOP events is registered during On power operational mode and lasted for two minutes or more. The plant centered events is the main contributor to LOOP events identified in IRSN, GRS and IAEA IRS database. The switchyard centered events are the main contributor in events registered in the NRC LER database. The main type of failed equipment is switchyard failures in IRSN and IAEA IRS, main or secondary lines in NRC LER and busbar failures in GRS database. The dominant root cause for the LOOP events are human failures during test, inspection and maintenance followed by human failures due to the insufficient or wrong procedures. The largest number of LOOP events resulted in reactor trip followed by EDG start. The actions that can result in reduction of the number of LOOP events and minimize consequences on plant safety are identified and presented.

  11. Heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter

    International Nuclear Information System (INIS)

    Sung, Hae-Jin; Go, Byeong-Soo; Jiang, Zhenan; Park, Minwon; Yu, In-Keun

    2016-01-01

    Highlights: • A large-scale HTS generator module has been suggested to avoid issues such as a huge vacuum vessel and higher reliability. • The challenging heat loss analysis of a large-scale HTS generator has successfully been performed, enabling the design of an optimal support structure having a total heat loss of 43 W/400 kW. • The results prove the potential of a large-scale superconducting wind-power generator to operate efficiently, and support further development of the concept. - Abstract: The development of an effective high-temperature superconducting (HTS) generator is currently a research focus; however, the reduction of heat loss of a large-scale HTS generator is a challenge. This study deals with a heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter. The generator module consists of an HTS rotor of the generator and an HTS flux pump exciter. The specifications of the module were described, and the detailed configuration of the module was illustrated. For the heat loss analysis of the module, the excitation loss of the flux pump exciter, eddy current loss of all of the structures in the module, radiation loss, and conduction loss of an HTS coil supporter were assessed using a 3D finite elements method program. In the case of the conduction loss, different types of the supporters were compared to find out the supporter of the lowest conduction loss in the module. The heat loss analysis results of the module were reflected in the design of the generator module and discussed in detail. The results will be applied to the design of large-scale superconducting generators for wind turbines including a cooling system.

  12. Heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter

    Energy Technology Data Exchange (ETDEWEB)

    Sung, Hae-Jin, E-mail: haejin0216@gmail.com [Changwon National University, 20 Changwondaehak-ro, Changwon, 641-773 (Korea, Republic of); Go, Byeong-Soo [Changwon National University, 20 Changwondaehak-ro, Changwon, 641-773 (Korea, Republic of); Jiang, Zhenan [Robinson Research Institute, Victoria University of Wellington, PO Box 33436 (New Zealand); Park, Minwon [Changwon National University, 20 Changwondaehak-ro, Changwon, 641-773 (Korea, Republic of); Yu, In-Keun, E-mail: yuik@changwon.ac.kr [Changwon National University, 20 Changwondaehak-ro, Changwon, 641-773 (Korea, Republic of)

    2016-11-15

    Highlights: • A large-scale HTS generator module has been suggested to avoid issues such as a huge vacuum vessel and higher reliability. • The challenging heat loss analysis of a large-scale HTS generator has successfully been performed, enabling the design of an optimal support structure having a total heat loss of 43 W/400 kW. • The results prove the potential of a large-scale superconducting wind-power generator to operate efficiently, and support further development of the concept. - Abstract: The development of an effective high-temperature superconducting (HTS) generator is currently a research focus; however, the reduction of heat loss of a large-scale HTS generator is a challenge. This study deals with a heat loss analysis-based design of a 12 MW wind power generator module having an HTS flux pump exciter. The generator module consists of an HTS rotor of the generator and an HTS flux pump exciter. The specifications of the module were described, and the detailed configuration of the module was illustrated. For the heat loss analysis of the module, the excitation loss of the flux pump exciter, eddy current loss of all of the structures in the module, radiation loss, and conduction loss of an HTS coil supporter were assessed using a 3D finite elements method program. In the case of the conduction loss, different types of the supporters were compared to find out the supporter of the lowest conduction loss in the module. The heat loss analysis results of the module were reflected in the design of the generator module and discussed in detail. The results will be applied to the design of large-scale superconducting generators for wind turbines including a cooling system.

  13. Stator Current Harmonic Reduction in a Novel Half Quasi-Z-Source Wind Power Generation System

    Directory of Open Access Journals (Sweden)

    Shoudao Huang

    2016-09-01

    Full Text Available The generator stator current gets distorted with unacceptable levels of total harmonic distortion (THD because impedance-source wind power generation systems use three-phase diode rectifiers. The stator current harmonics will cause increasing losses and torque ripple, which reduce the efficiency and stability of the system. This paper proposes a novel half quasi-Z-source inverter (H-qZSI for grid-connected wind power generation systems, which can reduce the generator stator current harmonics a great deal. When H-qZSI operates in the shoot-through zero state, the derivative of the generator stator current is only determined by the instantaneous value of the generator stator voltage, so the nonlinear relationship between generator stator current and stator voltage is improved compared with the traditional impedance-source inverter. Theoretically, it is indicated that the stator current harmonics can be reduced effectively by means of the proposed H-qZSI. Finally, simulation and experimental results are given to verify the theoretical analysis.

  14. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    2017-01-01

    Wind energy is the fastest growing source of renewable energy, but as wind farms are getting larger and more remotely located, installation and infrastructure costs are rising. It is estimated that the expenses for electrical infrastructure account for 15-30% of the overall initial costs, hence...... that must be spent immediately in cable and installation costs, and the future reduced revenues due to power losses. The latter goal has not been addressed in previous work. We present a Mixed-Integer Linear Programming approach to optimize the routing using both exact and math-heuristic methods....... In the power losses computation, wind scenarios are handled eciently as part of the preprocessing, resulting in a MIP model of only slightly larger size. A library of real-life instances is introduced and made publicly available for benchmarking. Computational results on this testbed show the viability of our...

  15. Optimizing wind farm cable routing considering power losses

    DEFF Research Database (Denmark)

    Fischetti, Martina; Pisinger, David

    Wind energy is the fastest growing source of renewable energy, but as wind farms are getting larger and more remotely located, installation and infrastructure costs are rising. It is estimated that the expenses for electrical infrastructure account for 15-30% of the overall initial costs, hence...... that must be spent immediately in cable and installation costs, and the future reduced revenues due to power losses. The latter goal has not been addressed in previous work. We present a Mixed-Integer Linear Programming approach to optimize the routing using both exact and math-heuristic methods....... In the power losses computation, wind scenarios are handled eciently as part of the preprocessing, resulting in a MIP model of only slightly larger size. A library of real-life instances is introduced and made publicly available for benchmarking. Computational results on this testbed show the viability of our...

  16. Study on ac losses of HTS coil carrying ac transport current

    International Nuclear Information System (INIS)

    Dai Taozhen; Tang Yuejin; Li Jingdong; Zhou Yusheng; Cheng Shijie; Pan Yuan

    2005-01-01

    Ac loss has an important influence on the thermal performances of HTS coil. It is necessary to quantify ac loss to ascertain its impact on coil stability and for sizing the coil refrigeration system. In this paper, we analyzed in detail the ac loss components, hysteresis loss, eddy loss and flux flow loss in the pancake HTS coil carrying ac transport current by finite element method. We also investigated the distribution of the ac losses in the coil to study the effects of magnetic field distribution on ac losses

  17. Risk of loss power for ATWT in Daya Bay and Ling'ao nuclear power stations

    International Nuclear Information System (INIS)

    Guo Cheng

    2010-01-01

    In order to analyze the differences between the Anticipated Transient Without Reactor Trip (ATWT) and other reactor protection methods, this paper analyzes in detail the realizing means of ATWT and the effect of lost of power supply on the units based on Daya Bay and Ling'ao Nuclear Power Stations by system wiring diagram. Based on the comprehensive analysis,this paper proposes the sequence for powering when recovering the power source after ATWT power supply (LCC/LNE) loss for Daya Bay and Ling'ao Nuclear Power Stations. (authors)

  18. Power loss analysis of n-PASHA cells validated by 2D simulations

    Energy Technology Data Exchange (ETDEWEB)

    Janssen, G.J.M.; Gutjahr, A.; Burgers, A.R.; Saynova, D.S.; Cesar, I.; Romijn, I.G.

    2013-10-15

    To reach >21% efficiency for the n-Pasha (passivated all sides H-pattern) cell of ECN, reliable power-loss analyses are essential. A power-loss analysis is presented that is based on experimental data but validated and completed by 2D simulations. The analysis is used to identify the key factors that will contribute most to achieving >21% efficiency.

  19. Mathematical analysis and coordinated current allocation control in battery power module systems

    Science.gov (United States)

    Han, Weiji; Zhang, Liang

    2017-12-01

    As the major energy storage device and power supply source in numerous energy applications, such as solar panels, wind plants, and electric vehicles, battery systems often face the issue of charge imbalance among battery cells/modules, which can accelerate battery degradation, cause more energy loss, and even incur fire hazard. To tackle this issue, various circuit designs have been developed to enable charge equalization among battery cells/modules. Recently, the battery power module (BPM) design has emerged to be one of the promising solutions for its capability of independent control of individual battery cells/modules. In this paper, we propose a new current allocation method based on charging/discharging space (CDS) for performance control in BPM systems. Based on the proposed method, the properties of CDS-based current allocation with constant parameters are analyzed. Then, real-time external total power requirement is taken into account and an algorithm is developed for coordinated system performance control. By choosing appropriate control parameters, the desired system performance can be achieved by coordinating the module charge balance and total power efficiency. Besides, the proposed algorithm has complete analytical solutions, and thus is very computationally efficient. Finally, the efficacy of the proposed algorithm is demonstrated using simulations.

  20. Report on achievement in developing an ultra low loss power element technology. Survey on practical application of the next generation power semiconductor devices; 1998 nendo choteisonshitsu denryoku soshi gijutsu kaihatsu seika hokokusho. Jisedai power handotai device jitsuyoka chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    Trends were surveyed for development of an ultra low loss power element. Performance improvement has been progressed on power semiconductor elements by using Si as the raw material, but loss reduction has come close to the physical limit. SiC is expected of possibility to go beyond this limit. SiC is so very excellent that its band gap is two to three times greater, insulation breakdown electric field is 7.5 times higher, temperature to become a true semiconductor is three to four times higher than those of Si. The wide gap can reduce high temperature leaking current in p-n junctions, and the increased authenticity temperature can increase the upper limit for operation temperature. The insulation breakdown strength being higher by one digit can reduce the drift layer thickness, and is expected to dramatically reduce the loss. The problem is that high quality crystals have not been obtained to date. One of the promising application fields is electric vehicle. The device currently using the power element in the largest scale is used in frequency converting stations to link the 50-Hz power network in the eastern part of Japan to the 60-Hz network in the western part of Japan. Surveys were carried out on the Sakuma frequency converting station and the New Shinano substation. (NEDO)

  1. Power transistor module for high current applications

    International Nuclear Information System (INIS)

    Cilyo, F.F.

    1975-01-01

    One of the parts needed for the control system of the 400-GeV accelerator at Fermilab was a power transistor with a safe operating area of 1800A at 50V, dc current gain of 100,000 and 20 kHz bandwidth. Since the commercially available discrete devices and power hybrid packages did not meet these requirements, a power transistor module was developed which performed satisfactorily. By connecting 13 power transistors in parallel, with due consideration for network and heat dissipation problems, and by driving these 13 with another power transistor, a super power transistor is made, having an equivalent current, power, and safe operating area capability of 13 transistors. For higher capabilities, additional modules can be conveniently added. (auth)

  2. Modeling time to recovery and initiating event frequency for loss of off-site power incidents at nuclear power plants

    International Nuclear Information System (INIS)

    Iman, R.L.; Hora, S.C.

    1988-01-01

    Industry data representing the time to recovery of loss of off-site power at nuclear power plants for 63 incidents caused by plant-centered losses, grid losses, or severe weather losses are fit with exponential, lognormal, gamma and Weibull probability models. A Bayesian analysis is used to compare the adequacy of each of these models and to provide uncertainty bounds on each of the fitted models. A composite model that combines the probability models fitted to each of the three sources of data is presented as a method for predicting the time to recovery of loss of off-site power. The composite model is very general and can be made site specific by making adjustments on the models used, such as might occur due to the type of switchyard configuration or type of grid, and by adjusting the weights on the individual models, such as might occur with weather conditions existing at a particular plant. Adjustments in the composite model are shown for different models used for switchyard configuration and for different weights due to weather. Bayesian approaches are also presented for modeling the frequency of initiating events leading to loss of off-site power. One Bayesian model assumes that all plants share a common incidence rate for loss of off-site power, while the other Bayesian approach models the incidence rate for each plant relative to the incidence rates of all other plants. Combining the Bayesian models for the frequency of the initiating events with the composite Bayesian model for recovery provides the necessary vehicle for a complete model that incorporates uncertainty into a probabilistic risk assessment

  3. Power loss benchmark of nine-switch converters in three-phase online-UPS application

    DEFF Research Database (Denmark)

    Qin, Zian; Loh, Poh Chiang; Blaabjerg, Frede

    2014-01-01

    Three-phase online-UPS is an appropriate application for the nine-switch converter, where its high voltage stress of the power device caused by the reduced switch feature can be relieved significantly. Its power loss and loss distribution still have the flexibility from the control point of view...... as parameters like modulation index and phase angle of the load are taken into account. The benchmark of power loss will become a guidance for the users to make best use of the advantages and bypass the disadvantages of nine-switch converters. The results are finally verified on a 1.5 kW prototype....

  4. Understanding energy loss in parallelly connected microbial fuel cells: Non-Faradaic current.

    Science.gov (United States)

    An, Junyeong; Sim, Junyoung; Feng, Yujie; Lee, Hyung-Sool

    2016-03-01

    In this work, the mechanisms of energy loss in parallel connection of microbial fuel cells (MFCs) is explored using two MFC units producing different open circuit voltage (OCV) and current. In open circuit mode, non-Faradaic current flows in low OCV unit, implying energy loss caused by different OCVs in parallelly stacked MFCs. In a stacked MFC in parallel under close circuit mode, it is confirmed that energy loss occurs until the working voltage in high OCV unit becomes identical to the other unit having low OCV. This result indicates that different voltage between individual MFC units can cause energy loss due to both non-Faradic and Faradaic current that flow from high voltage unit to low voltage unit even in parallelly stacked MFCs. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Core-powered mass-loss and the radius distribution of small exoplanets

    Science.gov (United States)

    Ginzburg, Sivan; Schlichting, Hilke E.; Sari, Re'em

    2018-05-01

    Recent observations identify a valley in the radius distribution of small exoplanets, with planets in the range 1.5-2.0 R⊕ significantly less common than somewhat smaller or larger planets. This valley may suggest a bimodal population of rocky planets that are either engulfed by massive gas envelopes that significantly enlarge their radius, or do not have detectable atmospheres at all. One explanation of such a bimodal distribution is atmospheric erosion by high-energy stellar photons. We investigate an alternative mechanism: the luminosity of the cooling rocky core, which can completely erode light envelopes while preserving heavy ones, produces a deficit of intermediate sized planets. We evolve planetary populations that are derived from observations using a simple analytical prescription, accounting self-consistently for envelope accretion, cooling and mass-loss, and demonstrate that core-powered mass-loss naturally reproduces the observed radius distribution, regardless of the high-energy incident flux. Observations of planets around different stellar types may distinguish between photoevaporation, which is powered by the high-energy tail of the stellar radiation, and core-powered mass-loss, which depends on the bolometric flux through the planet's equilibrium temperature that sets both its cooling and mass-loss rates.

  6. Application of parallel connected power-MOSFET elements to high current d.c. power supply

    International Nuclear Information System (INIS)

    Matsukawa, Tatsuya; Shioyama, Masanori; Shimada, Katsuhiro; Takaku, Taku; Neumeyer, Charles; Tsuji-Iio, Shunji; Shimada, Ryuichi

    2001-01-01

    The low aspect ratio spherical torus (ST), which has single turn toroidal field coil, requires the extremely high d.c. current like as 20 MA to energize the coil. Considering the ratings of such extremely high current and low voltage, power-MOSFET element is employed as the switching device for the a.c./d.c. converter of power supply. One of the advantages of power-MOSFET element is low on-state resistance, which is to meet the high current and low voltage operation. Recently, the capacity of power-MOSFET element has been increased and its on-state resistance has been decreased, so that the possibility of construction of high current and low voltage a.c./d.c. converter with parallel connected power-MOSFET elements has been growing. With the aim of developing the high current d.c. power supply using power-MOSFET, the basic characteristics of parallel operation with power-MOSFET elements are experimentally investigated. And, the synchronous rectifier type and the bi-directional self commutated type a.c./d.c. converters using parallel connected power-MOSFET elements are proposed

  7. Power loss and energy density of the asymmetric ultracapacitor loaded with molybdenum doped manganese oxide

    International Nuclear Information System (INIS)

    Wang, Yue-Sheng; Tsai, Dah-Shyang; Chung, Wen-Hung; Syu, Yong-Sin; Huang, Ying-Sheng

    2012-01-01

    Highlights: ► Mo-doping (15 mol%) enhances capacitance and diminishes oxide resistance. ► Influences of Mo-doped MnO 2 are analyzed at the level of capacitor power and energy. ► Polarization loss of the asymmetric capacitor is more than that of the symmetric one. ► Pseudocapacitance benefit on energy is evaluated with power and current densities. - Abstract: Ultracapacitors of asymmetric configuration have been prepared with activated carbon (AC) and undoped or Mo-doped manganese oxide (MnO 2 ) in 1.0 M Na 2 SO 4 electrolyte. Phase analysis shows the AC powder, 1–15 μm in size, contains both disordered and graphitic structures, and the undoped and Mo-doped oxide powder, 0.05–0.20 μm in particle size, mainly involves amorphous MnO 2 and MoO 2 . CV results indicate the single electrode of AC plus 10 wt% Mo-doped MnO 2 (A9O M 1) is superior to the electrode with undoped MnO 2 or high content of doped MnO 2 , exhibiting features of double layer capacitance at high scan rate and pseudocapacitance characteristics at low scan rate. When assembled with a negative electrode of AC, the capacitor of positive A9O M 1 electrode demonstrates the least power loss among three asymmetric capacitors. This asymmetric capacitor also shows a higher capacitance than the symmetric AC capacitor when the current density is less than 8.0 A g −1 in 1.8 V potential window. But a higher electrode resistance of A9O M 1, in contrast with AC, compromises its capacitance plus. When the energy density of A9O M 1 asymmetric capacitor is compared with that of symmetric AC capacitor at the same power level, the capacitance benefit on energy density is restricted to current density ≤ 3.0 A g −1 .

  8. A mathematical technique for hybrid power system design with energy loss considerations

    International Nuclear Information System (INIS)

    Lee, Jui-Yuan; Chen, Cheng-Liang; Chen, Hui-Chu

    2014-01-01

    Highlights: • A superstructure-based model is developed for hybrid power system design. • The model considers various power losses occurring in hybrid power systems. • The model locates rigorous outsourced electricity targets. • The model determines the minimum electricity storage capacity required. • Three literature case studies are solved to demonstrate the use of the model. - Abstract: This paper presents a generic mathematical optimisation model for the design of hybrid power systems (HPSs). The model takes into account power losses during the allocation of power generated from renewables to appliance loads, and is formulated as a linear programme (LP) based on a superstructure including all possible power allocation options in a typical HPS. With given power source and demand data for an HPS, the minimum outsourced electricity supply and the minimum electricity storage capacity required can be determined through a two-step optimisation. Three literature case studies are solved to illustrate the proposed approach

  9. n value and Jc distribution dependence of AC transport current losses in HTS conductors

    International Nuclear Information System (INIS)

    Ogawa, Jun; Sawai, Yusuke; Nakayama, Haruki; Tsukamoto, Osami; Miyagi, Daisuke

    2004-01-01

    Compared with LTS materials, HTS materials have some peculiarities affecting AC loss characteristics of the conductors. We measured the AC transport current losses in YBCO thin film coated conductors and a Bi2223/Ag sheathed tape. Comparing the measured data with analytical calculations, the dependence of the AC transport current losses on the n value and critical current density distributions are studied. It is shown that, considering the n values and J c distributions, the peculiarities in the HTS materials can be taken into consideration and the transport current losses in HTS conductors can be calculated by the same analytical method used for LTS

  10. Effect of different methods of pulse width modulation on power losses in an induction motor

    Science.gov (United States)

    Gulyaev, Alexander; Fokin, Dmitrii; Shuharev, Sergey; Ten, Evgenii

    2017-10-01

    We consider the calculation of modulation power losses in a system “induction motor-inverter” for various pulse width modulation (PWM) methods of the supply voltage. Presented values of modulation power losses are the result of modeling a system “DC link - two-level three-phase voltage inverter - induction motor - load”. In this study the power losses in a system “induction motor - inverter” are computed, as well as losses caused by higher harmonics of PWM supply voltage, followed by definition of active power consumed by the DC link for a specified value mechanical power on the induction motor shaft. Mechanical power was determined by the rotation speed and the torque on the motor shaft in various quasi-sinusoidal supply voltage PWM modes. These calculations reveal the best coefficient of performance (COP) in a system of a variable frequency drive (VFD) with independent voltage inverter controlled by induction motor PWM.

  11. Loss and thermal model for power semiconductors including device rating information

    DEFF Research Database (Denmark)

    Ma, Ke; Bahman, Amir Sajjad; Beczkowski, Szymon

    2014-01-01

    The electrical loading and device rating are both important factors that determine the loss and thermal behaviors of power semiconductor devices. In the existing loss and thermal models, only the electrical loadings are focused and treated as design variables, while the device rating is normally...

  12. Measurement of Radiated Power Loss on EAST

    International Nuclear Information System (INIS)

    Duan Yanmin; Hu Liqun; Mao Songtao; Xu Ping; Chen Kaiyun; Lin Shiyao; Zhong Guoqiang; Zhang Jizong; Zhang Ling; Wang Liang

    2011-01-01

    A type of silicon detector known as AXUV (absolute extreme ultraviolet) photodiodes is successfully used to measure the radiated power in EAST. The detector is characterized by compact structure, fast temporal response (<0.5 s) and flat spectral sensitivity in the range from ultra-violet to X-ray. Two 16-channel AXUV arrays are installed in EAST to view the whole poloidal cross-section of plasma. Based on the diagnostic system, typical radiation distributions for both limiter and divertor plasma are obtained and compared. As divertor detachment occurs, the radiation distribution in X-point region is observed to vary distinctly. The total radiation power losses in discharges with different plasma parameters are briefly analyzed.

  13. Power spectra of currents off Bombay

    Digital Repository Service at National Institute of Oceanography (India)

    Varkey, M.J.

    Current measurements were carried out using a recording current meter across the continental shelf off Bombay, Maharashtra, India at 4 stations from an anchored ship. Power spectra were computed for selected lengths of records. Spectral energy...

  14. Permanent Magnet Eddy Current Loss Analysis of a Novel Motor Integrated Permanent Magnet Gear

    DEFF Research Database (Denmark)

    Zhang, Yuqiu; Lu, Kaiyuan; Ye, Yunyue

    2012-01-01

    In this paper, a new motor integrated permanent magnet gear (MIPMG) is discussed. The focus is on eddy current loss analysis associated to permanent magnets (PMs). A convenient model of MIPMG is provided based on 2-D field-motion coupled time-stepping finite element method for transient eddy...... current analysis. The model takes the eddy current effect of PMs into account in determination of the magnetic field in the air-gap and in the magnet regions. The eddy current losses generated in the magnets are properly interpreted. Design improvements for reducing the eddy current losses are suggested...

  15. Simultaneous measurements of ion and electron currents using a novel compact electrostatic end-loss-current detector

    Science.gov (United States)

    Hirata, M.; Miyake, Y.; Cho, T.; Kohagura, J.; Numakura, T.; Shimizu, K.; Ito, M.; Kiminami, S.; Morimoto, N.; Hirai, K.; Yamagishi, T.; Miyata, Y.; Nakashima, Y.; Miyoshi, S.; Ogura, K.; Kondoh, T.; Kariya, T.

    2006-10-01

    For the purpose of end-loss-ion and -electron analyses in open-field plasmas, a compact-sized electrostatic end-loss-current detector is proposed on the basis of a self-collection principle for suppressing the effects of secondary-electron emission from a metal collector. For employing this specific method, it is worth noting that no further additional magnetic systems except the ambient open-ended magnetic fields are required in the detector operation. This characteristic property provides a compactness of the total detection system and availability for its use in plasma confinement devices without disturbing plasma-confining magnetic fields. The detector consists of a set of parallel metal plates with respect to lines of ambient magnetic forces of a plasma device for analyzing incident ion currents along with a grid for shielding the collector against strays due to the metal-plate biasing. The characterization experiments are carried out by the use of a test-ion-beam line along with an additional use of a Helmholtz coil system for the formation of open magnetic fields similar to those in the GAMMA 10 end region. The applications of the developed end-loss-current detector in the GAMMA 10 plasma experiments are demonstrated under the conditions with simultaneous incidence of energetic electrons produced by electron-cyclotron heatings for end-loss-plugging potential formation.

  16. Eddy current loss calculation and thermal analysis of axial-flux permanent magnet couplers

    Directory of Open Access Journals (Sweden)

    Di Zheng

    2017-02-01

    Full Text Available A three-dimensional magnetic field analytical model of axial-flux permanent magnet couplers is presented to calculate the eddy current loss, and the prediction of the copper plate temperature under various loads is analyzed. The magnetic field distribution is calculated, and then the eddy current loss is obtained, with the magnetic field analytical model established in cylindrical coordinate. The influence of various loads on eddy current loss is analyzed. Furthermore, a thermal model of axial-flux permanent magnet couplers is established by taking the eddy current loss as the heat source, using the electromagnetic-thermal coupled method. With the help of the thermal model, the influence of various loads on copper plate temperature rise is also analyzed. The calculated results are compared with the results of finite element method and measurement. The comparison results confirm the validity of the magnetic field analytical model and thermal model.

  17. Measurements of Plasma Power Losses in the C-2 Field-Reversed Configuration Experiment

    Science.gov (United States)

    Korepanov, Sergey; Smirnov, Artem; Garate, Eusebio; Donin, Alexandr; Kondakov, Alexey; Singatulin, Shavkat

    2013-10-01

    A high-confinement operating regime with plasma lifetimes significantly exceeding past empirical scaling laws was recently obtained by combining plasma gun edge biasing and tangential Neutral Beam Injection in the C-2 field-reversed configuration (FRC) experiment. To analyze the power balance in C-2, two new diagnostic instruments - the pyroelectric (PE) and infrared (IR) bolometers - were developed. The PE bolometer, designed to operate in the incident power density range from 0.1-100 W/cm2, is used to measure the radial power loss, which is dominated by charge-exchange neutrals and radiation. The IR bolometer, which measures power irradiated onto a thin metal foil inserted in the plasma, is designed for the power density range from 0.5-5 kW/cm2. The IR bolometer is used to measure the axial power loss from the plasma near the end divertors. The maximum measurable pulse duration of ~ 10 ms is limited by the heat capacitance of the IR detector. Both detectors have time resolution of about 10-100 μs and were calibrated in absolute units using a high power neutral beam. We present the results of first direct measurements of axial and radial plasma power losses in C-2.

  18. Power Deposition due to Muon Decay Losses in a Neutrino Factory

    CERN Document Server

    Keil, Eberhard

    2000-01-01

    The power in the charged muon decay products, deposited per unit distance, depends on the muon energy only through the relativistic factor beta. For a typical neutrino factory it is about one Watt/m, multiplied by the number of passes through a particular component. The power is highest in the muon decay ring, where the muon lifetime cooresponds to about 150 turns. The electrons or positrons from muon decay in the long straight section may remain inside the vacuum chamber, until they are lost at the beginning of the arcs, because of their large energy errors, that are enhanced by synchrotron radiation losses. The power losses along the straight section and the arcs are studied by computer simulation, and the results are presented. About two thirds of the power ends up in the straight section, the remainder in the matching section and in the first half of the dispersion suppressor.

  19. Closeout of IE Bulletin 80-15: Possible loss of Emergency Notification System (ENS) with loss of offsite power

    International Nuclear Information System (INIS)

    Foley, W.J.; Dean, R.S.; Hennick, A.

    1990-12-01

    Documentation is provided in this report for the closeout of IE Bulletin 80-15 for nuclear power reactors. This bulletin pertained to a possible loss of the Emergency Notification System (ENS) upon loss of offsite power. Closeout is based on the implementation and verification of six (6) required actions by licensees of nuclear power reactors in operation or near to receiving an operating license when the bulletin was issued on June 18, 1980. Evaluation of utility responses and NRC/Region inspection reports indicates that the bulletin is closed for all of the 69 nuclear power reactors to which it was issued for action and which were not shut down indefinitely or permanently at the time of issuance of this report. Background information is supplied in the Introduction and Appendix A. Nuclear fuel facilities as well as nuclear power facilities were identified in the enclosures to the bulletin. However, per an NRC memorandum, the closeout of the bulletin for nuclear fuel facilities is not within the scope of this report

  20. Current-Driven Switch-Mode Audio Power Amplifiers

    DEFF Research Database (Denmark)

    Knott, Arnold; Buhl, Niels Christian; Andersen, Michael A. E.

    2012-01-01

    The conversion of electrical energy into sound waves by electromechanical transducers is proportional to the current through the coil of the transducer. However virtually all audio power amplifiers provide a controlled voltage through the interface to the transducer. This paper is presenting...... a switch-mode audio power amplifier not only providing controlled current but also being supplied by current. This results in an output filter size reduction by a factor of 6. The implemented prototype shows decent audio performance with THD + N below 0.1 %....

  1. Power system stabilization by SMES using current-fed pwm power conditioner

    International Nuclear Information System (INIS)

    Ishikawa, T.; Akita, S.; Taniguchi, H.; Kosho, S.; Tanaka, T.

    1988-01-01

    A superconducting magnetic energy storage (SMES) unit, consisted of superconducting coil and AC/DC power conditioner, can be used to suppress various kinds of instability that may cause service interruption in electric power system as it has high controllability of input/output electric power. Power system stabilizing ability of SMES has been examined experimentally by using model power system and small SMES unit. Current-fed PWM power conditioner was used to obtain maximum stabilizing effect by controlling active and reactive power simultaneously and independently. Power conditioner configuration, operating characteristics and control scheme for power system stabilization are also described. Results from experiments show the effectiveness of SMES on power system stabilization

  2. Energy losses in the D0 β solenoid cryostat caused by current changes

    International Nuclear Information System (INIS)

    Visser, A.T.

    1993-11-01

    The proposed D0 β solenoid is a superconducting solenoid mounted inside an aluminum tube which supports the solenoid winding over it's full length. This aluminum support tube, also called bobbin, is therefore very tightly coupled to magnetic flux changes caused by solenoid current variations. These current changes in the solenoid, will cause answer currents to flow in the resistive bobbin wall and therefore cause heat losses. The insertion of an external dump resistor in the solenoid current loop reduces energy dissipation inside the cryostat during a quench and will shorten the discharge time constant. This note presents a simple electrical model for the coupled bobbin and solenoid and makes it easier to understand the circuit behavior and losses. Estimates for the maximum allowable rate of solenoid current changes, based on the maximum permissible rate of losses can be made using this model

  3. Low-loss ultracompact optical power splitter using a multistep structure.

    Science.gov (United States)

    Huang, Zhe; Chan, Hau Ping; Afsar Uddin, Mohammad

    2010-04-01

    We propose a low-loss ultracompact optical power splitter for broadband passive optical network applications. The design is based on a multistep structure involving a two-material (core/cladding) system. The performance of the proposed device was evaluated through the three-dimensional finite-difference beam propagation method. By using the proposed design, an excess loss of 0.4 dB was achieved at a full branching angle of 24 degrees. The wavelength-dependent loss was found to be less than 0.3 dB, and the polarization-dependent loss was less than 0.05 dB from O to L bands. The device offers the potential of being mass-produced using low-cost polymer-based embossing techniques.

  4. Current stopping power analyses

    International Nuclear Information System (INIS)

    Porter, L.E.

    1983-01-01

    Modified Bethe-Bloch stopping power theory permits fairly accurate calculation of energy losses over a broad interval of projectile velocity v = νc insofar as several parameters appearing in the revised Bethe-Bloch formula have been corectly evaluated. Since the parameters cannot in general be ascertained by calculation from first principles, fits of theory to measurement remain the best method of evaluation. The parameters alluded to are: the target mean excitation energy; the shell correction scaling parameters; the composite single free parameter of the Barkas (projectile-z 3 ) effect correction formalism, and the strength of the correction term; the high velocity density effect correction parameter; and the low velocity charge state parameter. These parameters are discussed

  5. Current amplification models of sensorineurall and conductive hearing loss

    Directory of Open Access Journals (Sweden)

    Ostojić Sanja

    2012-01-01

    Full Text Available The main function of a hearing aid is to improve auditory and language abilities of hearing impaired users. The amplification model has to be adapted according to age, degree and type of hearing loss. The goal of this paper is to analyze the current amplification models of sensorineural and conductive hearing loss which can provide a high quality of speech perception and sounds at any degree of hearing loss. The BAHA is a surgically implantable system for treatment of conductive hearing loss that works through direct bone conduction. BAHA is used to help people with chronic ear infections, congenital external auditory canal atresia and single sided deafness who cannot benefit from conventional hearing aids. The last generation of hearing aid for sensorineural hearing loss is cochlear implant. Bimodal amplification improves binaural hearing. Hearing aids alone do not make listening easier in all situations. The things that can interfere with listening are background noises, distance from a sound and reverberation or echo. The device used most often today is the Frequency Modulated (FM system.

  6. Optimizing real power loss and voltage stability limit of a large transmission network using firefly algorithm

    Directory of Open Access Journals (Sweden)

    P. Balachennaiah

    2016-06-01

    Full Text Available This paper proposes a Firefly algorithm based technique to optimize the control variables for simultaneous optimization of real power loss and voltage stability limit of the transmission system. Mathematically, this issue can be formulated as nonlinear equality and inequality constrained optimization problem with an objective function integrating both real power loss and voltage stability limit. Transformers taps, unified power flow controller and its parameters have been included as control variables in the problem formulation. The effectiveness of the proposed algorithm has been tested on New England 39-bus system. Simulation results obtained with the proposed algorithm are compared with the real coded genetic algorithm for single objective of real power loss minimization and multi-objective of real power loss minimization and voltage stability limit maximization. Also, a classical optimization method known as interior point successive linear programming technique is considered here to compare the results of firefly algorithm for single objective of real power loss minimization. Simulation results confirm the potentiality of the proposed algorithm in solving optimization problems.

  7. Current measurement method for characterization of fast switching power semiconductors with Silicon Steel Current Transformer

    DEFF Research Database (Denmark)

    Li, Helong; Beczkowski, Szymon; Munk-Nielsen, Stig

    2015-01-01

    This paper proposes a novel current measurement method with Silicon Steel Current Transformer (SSCT) for the characterization of fast switching power semiconductors. First, the existing current sensors for characterization of fast switching power semiconductors are experimentally evaluated...

  8. Impact of distributed generators on the power loss and voltage profile of sub-transmission network

    Directory of Open Access Journals (Sweden)

    A.S.O. Ogunjuyigbe

    2016-05-01

    Full Text Available This paper presents the impact of distributed generator (DG on the power loss and voltage profile of sub-transmission network at different penetration levels (PLs. The various DG technologies are modeled based on their electrical output characteristics. Voltage profile index which allows a single value to represent how well the voltage matches the ideal value is developed. The index allows a fair comparison of the voltage profile obtained from different scenarios. The extent to which DGs affect power losses and voltage profile depend on the type of DG technology, PL and the location in which the DG is connected to the grid. The integration of DGs reduces power losses on the network, however, as the PL increases, the power losses begin to increase. A PL of 50–75% is achieved on 69 kV voltage level and 25–50% penetration on 13.8 kV voltage level without an increase in the power loss. Also more DG can be integrated into the network at point of common connection of higher voltage level compared to the low voltage level.

  9. PCTRAN enhancement for large break loss of coolant accident concurrent with loss of offsite power in VVER-1000 simulation

    Energy Technology Data Exchange (ETDEWEB)

    Hadad, Kamal; Esmaeili-Sanjavanmareh, Mansour [Shiraz Univ., Shiraz (Iran, Islamic Republic of). Dept. of Nuclear Engineering

    2017-05-15

    PCTRAN capability to simulate a large break loss of coolant accident concurrent with the loss of offsite power in Bushehr Nuclear Power Plant is enhanced and investigated. Following the correction of the accident scenario for Bushehr nuclear power plant in PCTRAN, simulation results are compared with the final safety assessment report of that plant. As a result, the primary loop thermal hydraulics parameters including pressure, total flow rates, leakage flow rates and reactor power are in a good agreement with the reference data. Hot and cold leg temperature variations have the same trends as reference data but have a maximum of 80 C disagreement at the transient initiation. The reason for this disagreement is explained and its adjustment is discussed. Improvements of PCTRAN simulator are mainly due to enhancing user control for atmospheric steam dump valve, containment pressure and emergency core cooling systems which are thoroughly described in this paper.

  10. Effects of partial shading conditions on maximum power points and mismatch losses in silicon-based photovoltaic power generators

    Energy Technology Data Exchange (ETDEWEB)

    Maki, A.

    2013-11-01

    Photovoltaic (PV) power generators can be used for converting the energy of solar radiation directly into electrical energy without any moving parts. The operation of the generators is highly affected by operating conditions, most importantly irradiances and temperatures of PV cells. PV power generators are prone to electrical losses if the operating conditions are non-uniform such as in a case where part of the modules of a generator are shaded while the rest are receiving the global solar radiation. These conditions are called partial shading conditions and they have been recognized as a major cause of energy losses in PV power generators. In this thesis, the operation of silicon-based PV power generators under partial shading conditions is studied using Matlab Simulink simulation model. The operation of the model has been verified by measurements of electrical characteristics of a PV module under several different operating conditions and also under partial shading conditions. A systematic approach to study the effects of partial shading conditions has been developed and used. In addition to the systematic approach, a vast amount of data measured from the Tampere University of Technology (TUT) Solar Photovoltaic Power Station Research Plant are analyzed and used as input for the simulation model to study operation of PV power generators under actual operating conditions. Partial shading conditions have severe effects on the electrical characteristics of PV power generators and can cause multiple maximum power points (MPPs) to the power-voltage curve of the generators. In most cases, partial shading conditions lead to the occurrence of multiple MPPs, but also only one MPP can be present despite of partial shading. Reasons for this phenomenon are presented and analyzed in this thesis. Because of multiple MPPs, a considerable amount of available electrical energy may be lost when the generator is operating at a local MPP with low power instead of the global MPP. In

  11. Calculation of harmonic losses and ampacity in low-voltage power cables when used for feeding large LED lighting loads

    Directory of Open Access Journals (Sweden)

    N. J. Milardovich

    2014-10-01

    Full Text Available A numerical investigation on the harmonic disturbances in low-voltage cables feeding large LED loads is reported. A frequency domain analysis on several commercially-available LEDs was performed to investigate the signature of the harmonic current injected into the power system. Four-core cables and four single-core cable arrangements (three phases and neutral of small, medium, and large conductor cross sections, with the neutral conductor cross section approximately equal to the half of the phase conductors, were examined. The cables were modelled by using electromagnetic finite-element analysis software. High harmonic power losses (up to 2.5 times the value corresponding to an undistorted current of the same rms value of the first harmonic of the LED current were found. A generalized ampacity model was employed for re-rating the cables. It was found that the cross section of the neutral conductor plays an important role in the derating of the cable ampacity due to the presence of a high-level of triplen harmonics in the distorted current. The ampacity of the cables should be derated by about 40 %, almost independent of the conductor cross sections. The calculation have shown that an incoming widespread use of LED lamps in lighting could create significant additional harmonic losses in the supplying low-voltage lines, and thus more severely harmonic emission limits should be defined for LED lamps.

  12. Detection of Frauds and Other Non-technical Losses in Power Utilities using Smart Meters: A Review

    Science.gov (United States)

    Ahmad, Tanveer; Ul Hasan, Qadeer

    2016-06-01

    Analysis of losses in power distribution system and techniques to mitigate these are two active areas of research especially in energy scarce countries like Pakistan to increase the availability of power without installing new generation. Since total energy losses account for both technical losses (TL) as well as non-technical losses (NTLs). Utility companies in developing countries are incurring of major financial losses due to non-technical losses. NTLs lead to a series of additional losses, such as damage to the network (infrastructure and the reduction of network reliability) etc. The purpose of this paper is to perform an introductory investigation of non-technical losses in power distribution systems. Additionally, analysis of NTLs using consumer energy consumption data with the help of Linear Regression Analysis has been carried out. This data focuses on the Low Voltage (LV) distribution network, which includes: residential, commercial, agricultural and industrial consumers by using the monthly kWh interval data acquired over a period (one month) of time using smart meters. In this research different prevention techniques are also discussed to prevent illegal use of electricity in the distribution of electrical power system.

  13. Critical power for lower hybrid current drive

    International Nuclear Information System (INIS)

    Assis, A.S. de; Sakanaka, P.H.; Azevedo, C.A. de; Busnardo-Neto, J.

    1995-11-01

    We have solved numerically the quasilinear Fokker-Planck equation which models the critical power for lower hybrid wave current drive. An exact value for the critical power necessary for current saturation, for tokamak current drive experiments, has been obtained. The nonlinear treatment presented here leads to a final profile for the parallel distribution function which is a plateau only in a part of the resonance region. This form of the distribution function is intermediate between two well known results: a plateau throughout the resonance region for the linear strong-source regime, D wave >> D coll and no plateau at all in the resonance region the linear weak-source regimen, D wave coll . The strength of the external power source and the value of the dc electric field are treated as given parameters in the integration scheme. (author). 24 refs, 6 figs

  14. Investigation of occurrences of loss of external power supply in Spanish nuclear power plants

    International Nuclear Information System (INIS)

    Conde, J.M.; Reig, J.

    1989-01-01

    The paper reports on an investigation undertaken by the Nuclear Safety Council into occurrences of loss of external power supply in Spanish light water plants between 1981 and 1987. During this period all of the plants investigated (nine), with the exception of one, experienced an event of this type. The causes, effects and duration of each are studied in detail and the conclusion is drawn that the main cause of this type of occurrence is the intrinsic instability of the Spanish national grid. The response of plants to these various failures in external power supply was studied, special attention being paid to the correct operation of safety systems. In addition, the behaviour of other systems not related to safety is discussed, as are modifications and actions taken as a result of accumulated experience with a view to improving the plant response in the event of the failure of the external power supply, and reducing the frequency of such occurrences and their effective duration. The data obtained from this analysis were compared with those obtained in studies performed in other countries and the conclusion was drawn that failures in the external power supply occur slightly more frequently in Spain than in other countries. Similarly, a comparison was drawn between plant response during an actual failure and the response obtained during loss of external power nuclear tests which are carried out in all Spanish plants during the startup (commissioning) programme, in order to ascertain whether the test itself is adequate. (author). 1 fig., 3 tabs

  15. Analysis of eddy current losses during discharging period in a 600 kJ SMES

    International Nuclear Information System (INIS)

    Park, M.J.; Kwak, S.Y.; Lee, S.Y.; Kim, W.S.; Lee, J.K.; Park, C.; Choi, K.; Bae, J.H.; Kim, S.H.; Sim, K.D.; Seong, K.C.; Jung, H.K.; Hahn, S.

    2008-01-01

    The operation of the SMES system can be divided into three modes such as charging, operating and discharging. During the charging and the discharging modes, a magnetic field variation due to the current increase and decrease generate eddy current losses in the SMES system. The eddy current loss in discharging mode is the major factor to be considered because the operating time in the mode is fixed, whereas the charging mode has the arbitrary operating time which is not fixed. In this paper, we present the analysis results of the eddy current losses which are generated in the 600 kJ class HTS SMES system during the discharging mode

  16. Losses of off-site power at U.S. nuclear power plants - all years through 1985. Final report, May 1986

    International Nuclear Information System (INIS)

    1986-05-01

    This report provides a database describing losses of all off-site power at U.S. nuclear plants. It includes all years through 1985. During 1985 there were 2 losses lasting longer than 30 minutes for 0.031 losses per site year and 4 shorter losses for 0.063 losses per site year, giving a total of 0.094 losses per site year. This is in line with the 1984 total of 0.089 losses per site year, and with the comparable numbers for all years through 1985 of 0.038 losses per site year of longer than 30 minutes, 0.045 for shorter losses and a total of 0.083. (author)

  17. Nonlinear and linear wave equations for propagation in media with frequency power law losses

    Science.gov (United States)

    Szabo, Thomas L.

    2003-10-01

    The Burgers, KZK, and Westervelt wave equations used for simulating wave propagation in nonlinear media are based on absorption that has a quadratic dependence on frequency. Unfortunately, most lossy media, such as tissue, follow a more general frequency power law. The authors first research involved measurements of loss and dispersion associated with a modification to Blackstock's solution to the linear thermoviscous wave equation [J. Acoust. Soc. Am. 41, 1312 (1967)]. A second paper by Blackstock [J. Acoust. Soc. Am. 77, 2050 (1985)] showed the loss term in the Burgers equation for plane waves could be modified for other known instances of loss. The authors' work eventually led to comprehensive time-domain convolutional operators that accounted for both dispersion and general frequency power law absorption [Szabo, J. Acoust. Soc. Am. 96, 491 (1994)]. Versions of appropriate loss terms were developed to extend the standard three nonlinear wave equations to these more general losses. Extensive experimental data has verified the predicted phase velocity dispersion for different power exponents for the linear case. Other groups are now working on methods suitable for solving wave equations numerically for these types of loss directly in the time domain for both linear and nonlinear media.

  18. Alternating-current transport losses of melt-cast processed Bi-2212 bulk superconductor bars

    International Nuclear Information System (INIS)

    Tsukamoto, T; Inada, R; Inagaki, N; Andoh, H; Sugiura, T; Oota, A

    2003-01-01

    Using a melt-casting method, we have fabricated two pieces of Bi-2212 bulk superconductor bar with square and rectangular cross-sections, and we have investigated the alternating-current (ac) transport self-field losses at 77 K. Despite the main contribution of hysteresis loss of the superconductor, there is some difference in the loss behaviour between these two samples. To elucidate the origin, we make numerical calculations on the ac transport self-field losses as a function of current amplitude I 0 below the critical current I c . At a fixed I 0 , the calculated values using the uniform J c distribution and the actual cross-sectional geometry are much higher than the experimental data for the sample with a square cross-section 7.5 x 7.5 mm 2 , while there is good agreement between the calculation and the experiment for the sample with a rectangular cross-section 4.5 x 13.6 mm 2 . The discrepancy appearing in the sample with a square cross-section is ascribed to the actual J c distribution, which is confirmed by critical current measurements when scraping off the sample. The local J c value decreases significantly in going from the surface to the interior of the sample. This suppresses the extension of the flux-penetration region to the interior under ac current transmission and lowers the loss generation compared with the calculated results obtained by the uniform J c distribution

  19. Analysis of power variation in a CANDU-6 with a loss of moderator

    International Nuclear Information System (INIS)

    Fan, Y.

    2008-01-01

    A loss of heavy water in a postulated small failure in the horizontal unpressurized calandria vessel of a CANDU-6 reactor will lead to a drop in the moderator level in the reactor core. The STEPBACK and SETBACK functions at the initial moment of the drop in moderator level ensure a reactor shutdown and a reduction in total reactor power during this 900 seconds postulated transient. If the STEPBACK and SETBACK functions are unavailable, the reactor's regulating system will try to compensate for the negative reactivity resulting from the loss of the moderator. This kind of compensation will lead to power distortions from top to bottom in the reactor core. .Comparisons of different moderator leakage rates were used in the analysis to determine the relationships between the power and the moderator leakage rates. Maximum bundle and channel powers obtained were insensitive to the moderator leakage rate. .In a complete analysis for a moderator leakage rate of 40 1/s, it was found that, without the STEPBACK and SETBACK functions, serious power distortions would occur during the 900 seconds transient. The maximization of bundle and channel power during this transient happened in the bottom part of the reactor , and the regulating system worsened this power distortion. .From the above analysis, it was concluded that the maximum bundle power attained during the loss of the moderator was 1.18% of its initial value. The risk of bundle dryout was, therefore, quite small. (author)

  20. Analysis of results from a loss-of-offsite-power-initiated ATWS experiment in the LOFT Facility

    International Nuclear Information System (INIS)

    Varacalle, D.J.; Giri, A.M.; Koizumi, Y.; Koske, J.E.

    1983-01-01

    An anticipated transient without scram (ATWS), initiated by loss-of-offsite power, was experimentally simulated in the Loss-of-Fluid Test (LOFT) pressurized water reactor (PWR). Primary system pressure was controlled using a scaled safety relief valve (SRV) representative of those in a commercial PWR, while reactor power was reduced by moderator reactivity feedback in a natural circulation mode. The experiment showed that reactor power decreases more rapidly when the primary pumps are tripped in a loss-of-offsite-power ATWS than in a loss-of-feedwater induced ATWS when the primary pumps are left on. During the experiment, the SRV had sufficient relief capacity to control primary system pressure. Natural circulation was effective in removing core heat at high temperature, pressure, and core power. The system transient response predicted using the RELAPS/MOD1 computer code showed good agreement with the experimental data

  1. Determination analaysis of the power losses of transformers with continuously transpored conductors (CTC) based fuzzy logic

    Science.gov (United States)

    Kaloko, Bambang Sri; Atsari, Erinna Dyah

    2017-03-01

    Electric motive force which flows into the iron core continuously on a plate - plate iron isolated may cause heat posed by current eddy (eddy current). No water loss occurs due to detainees on the circuit at the the flow of current load because this loss happened on the entanglement of the transformer is made of copper. Continuously Transposed Conductors (CTC) consist of a number of enameled rectangular wires (5-84 strands) made into an assembly. Each strand is transposed in turn to each position in the cable and is then covered with layers of insulation paper. Continuously Transposed Conductors are used in winding wires for medium and ultra high power transformers. CTC is manufactured by OFHC copper and indeed, is able to supply polyester roped. CTC which has been designed to reduce production cost, oil pocket and improve cooling efficiency. Hardened type CTC (CPR1, CPR2, and CPR3: BS1432) and Self-bonding CTC which can be used to improve mechanical and electrical strength are also available. This analysis is performed using the methods of fuzzy logic in taking account of the resources.

  2. Study on AC loss measurements of HTS power cable for standardizing

    Science.gov (United States)

    Mukoyama, Shinichi; Amemiya, Naoyuki; Watanabe, Kazuo; Iijima, Yasuhiro; Mido, Nobuhiro; Masuda, Takao; Morimura, Toshiya; Oya, Masayoshi; Nakano, Tetsutaro; Yamamoto, Kiyoshi

    2017-09-01

    High-temperature superconducting power cables (HTS cables) have been developed for more than 20 years. In addition of the cable developments, the test methods of the HTS cables have been discussed and proposed in many laboratories and companies. Recently the test methods of the HTS cables is required to standardize and to common in the world. CIGRE made the working group (B1-31) for the discussion of the test methods of the HTS cables as a power cable, and published the recommendation of the test method. Additionally, IEC TC20 submitted the New Work Item Proposal (NP) based on the recommendation of CIGRE this year, IEC TC20 and IEC TC90 started the standardization work on Testing of HTS AC cables. However, the individual test method that used to measure a performance of HTS cables hasn’t been established as world’s common methods. The AC loss is one of the most important properties to disseminate low loss and economical efficient HTS cables in the world. We regard to establish the method of the AC loss measurements in rational and in high accuracy. Japan is at a leading position in the AC loss study, because Japanese researchers have studied on the AC loss technically and scientifically, and also developed the effective technologies for the AC loss reduction. The JP domestic commission of TC90 made a working team to discussion the methods of the AC loss measurements for aiming an international standard finally. This paper reports about the AC loss measurement of two type of the HTS conductors, such as a HTS conductor without a HTS shield and a HTS conductor with a HTS shield. The AC loss measurement method is suggested by the electrical method..

  3. Chaotic improved PSO-based multi-objective optimization for minimization of power losses and L index in power systems

    International Nuclear Information System (INIS)

    Chen, Gonggui; Liu, Lilan; Song, Peizhu; Du, Yangwei

    2014-01-01

    Highlights: • New method for MOORPD problem using MOCIPSO and MOIPSO approaches. • Constrain-prior Pareto-dominance method is proposed to meet the constraints. • The limits of the apparent power flow of transmission line are considered. • MOORPD model is built up for MOORPD problem. • The achieved results by MOCIPSO and MOIPSO approaches are better than MOPSO method. - Abstract: Multi-objective optimal reactive power dispatch (MOORPD) seeks to not only minimize power losses, but also improve the stability of power system simultaneously. In this paper, the static voltage stability enhancement is achieved through incorporating L index in MOORPD problem. Chaotic improved PSO-based multi-objective optimization (MOCIPSO) and improved PSO-based multi-objective optimization (MOIPSO) approaches are proposed for solving complex multi-objective, mixed integer nonlinear problems such as minimization of power losses and L index in power systems simultaneously. In MOCIPSO and MOIPSO based optimization approaches, crossover operator is proposed to enhance PSO diversity and improve their global searching capability, and for MOCIPSO based optimization approach, chaotic sequences based on logistic map instead of random sequences is introduced to PSO for enhancing exploitation capability. In the two approaches, constrain-prior Pareto-dominance method (CPM) is proposed to meet the inequality constraints on state variables, the sorting and crowding distance methods are considered to maintain a well distributed Pareto optimal solutions, and moreover, fuzzy set theory is employed to extract the best compromise solution over the Pareto optimal curve. The proposed approaches have been examined and tested in the IEEE 30 bus and the IEEE 57 bus power systems. The performances of MOCIPSO, MOIPSO, and multi-objective PSO (MOPSO) approaches are compared with respect to multi-objective performance measures. The simulation results are promising and confirm the ability of MOCIPSO and

  4. Estimation of the loss of Offsite power frequency for the probabilistic safety assessment of the Juragua NPP

    International Nuclear Information System (INIS)

    Vilaragut Llanes, J.J.; Valhuerdi Debesa, C.

    1996-01-01

    The loss offsite power is defined as the interruption of the preferred power supply to the essential and non essential switchgear buses necessitating or resulting in the use of emergency AC power supply. Because many safety system required for reactor core decay heat removal and containment heat removal depend on AC power, a loss of offsite power, if emergency power supply (diesel generators) fails, could be severe accidents The purpose of this work was to determine, for the Probabilistic Safety Assessment of the Juragua NPP, the causes, frequency and duration relationships of the loss of offsite power. A description is presented of the different factor that determine the occurrence of this event and the characteristics for the Juragua NPP

  5. Economic simplified boiling water reactor (ESBWR) response to an extended station blackout/ loss of all AC power

    International Nuclear Information System (INIS)

    Barrett, A.J.; Marquino, W.

    2013-01-01

    U.S. federal regulations require light water cooled nuclear power plants to cope with Station Blackout for a predetermined amount of time based on design factors for the plant. U.S. regulations define Station Blackout (SBO) as a loss of the offsite electric power system concurrent with turbine trip and unavailability of the onsite emergency AC power system. According to U.S. regulations, typically the coping period for an SBO is 4 hours and can be as long as 16 hours for currently operating BWR plants. Being able to cope with an SBO and loss of all AC power is required by international regulators as well. The U.S. licensing basis for the ESBWR is a coping period of 72 hours for an SBO based on U.S. NRC requirements for passive safety plants. In the event of an extended SBO (viz., greater than 72 hours), the ESBWR response shows that the design is able to cope with the event for at least 7 days without AC electrical power or operator action. ESBWR is a Generation III+ reactor design with an array of passive safety systems. The ESBWR primary success path for mitigation of an SBO event is the Isolation Condenser System (ICS). The ICS is a passive, closed loop, safety system that initiates automatically on a loss of power. Upon Station Blackout or loss of all AC power, the ICS begins removing decay heat from the Reactor Pressure Vessel (RPV) by (i) condensing the steam into water in heat exchangers located in pools of water above the containment, and (ii) transferring the decay heat to the atmosphere. The condensed water is then returned by gravity to cool the reactor again. The ICS alone is capable of maintaining the ESBWR in a safe shutdown condition after an SBO for an extended period. The fuel remains covered throughout the SBO event. The ICS is able to remove decay heat from the RPV for at least 7 days and maintains the reactor in a safe shutdown condition. The water level in the RPV remains well above the top of active fuel for the duration of the SBO event

  6. Impacts on investments, and transmission/distribution loss through power sector reforms

    International Nuclear Information System (INIS)

    Nagayama, Hiroaki

    2010-01-01

    This study analyses original panel data from 86 countries between 1985 and 2006. Econometric methods were used to identify the effects of different policy devices of power sector reforms on performance indicators (installed capacity per capita, transmission and distribution loss) in the countries analyzed. The research findings suggest that reform variables such as the entry of independent power producers (IPPs), unbundling of generation and transmission, establishment of regulatory agencies, and the introduction of a wholesale spot market are the driving forces of increasing generation capacity, as well as reducing transmission and distribution loss in the respective regions. In this study, we can assume that, firstly, different electric industry's reform policies/measures have different impacts on geographically and economically diverse countries. Secondly, a country's state of economic development has a different impact on policy effects of reforms. Thirdly, coexistent with independent regulatory agencies, reform policy becomes more powerful in realizing sector performances.

  7. Roebel assembled coated conductor cables (RACC): Ac-Losses and current carrying potential

    Science.gov (United States)

    Frank, A.; Heller, R.; Goldacker, W.; Kling, A.; Schmidt, C.

    2008-02-01

    Low ac-loss HTS cables for transport currents well above 1 kA are required for application in transformers and generators and are taken into consideration for future generations of fusion reactor coils. Coated conductors (CC) are suitable candidates for high field application at an operation temperature in the range 50-77 K. Ac-field applications require cables with low ac-losses and hence twisting of the individual strands. We solved this problem using the Roebel technique. Short lengths of Roebel bar cables were prepared from industrial DyBCO and YBCO-CC. Meander shaped tapes of 4 or 5 mm width with twist pitches of 123 or 127 mm were cut from the 10 or 12 mm wide CC tapes using a specially designed tool. Eleven or twelve of these strands were assembled to a cable. The electrical and mechanical connection of the tapes was achieved using a silver powder filled conductive epoxy resin. Ac-losses of a short sample in an external ac-field were measured as a function of frequency and field amplitude as well as the coupling current decay time constant. We discuss the results in terms of available theories and compare measured time constants in transverse field with measured coupling losses. Finally the potential of this cable type for ac-use is discussed with respect to ac-losses and current carrying capability.

  8. Roebel assembled coated conductor cables (RACC): Ac-Losses and current carrying potential

    International Nuclear Information System (INIS)

    Frank, A; Heller, R; Goldacker, W; Kling, A; Schmidt, C

    2008-01-01

    Low ac-loss HTS cables for transport currents well above 1 kA are required for application in transformers and generators and are taken into consideration for future generations of fusion reactor coils. Coated conductors (CC) are suitable candidates for high field application at an operation temperature in the range 50-77 K. Ac-field applications require cables with low ac-losses and hence twisting of the individual strands. We solved this problem using the Roebel technique. Short lengths of Roebel bar cables were prepared from industrial DyBCO and YBCO-CC. Meander shaped tapes of 4 or 5 mm width with twist pitches of 123 or 127 mm were cut from the 10 or 12 mm wide CC tapes using a specially designed tool. Eleven or twelve of these strands were assembled to a cable. The electrical and mechanical connection of the tapes was achieved using a silver powder filled conductive epoxy resin. Ac-losses of a short sample in an external ac-field were measured as a function of frequency and field amplitude as well as the coupling current decay time constant. We discuss the results in terms of available theories and compare measured time constants in transverse field with measured coupling losses. Finally the potential of this cable type for ac-use is discussed with respect to ac-losses and current carrying capability

  9. Considerations for surviving the loss of a main feedwater pump at full power

    International Nuclear Information System (INIS)

    Gaydos, K.A.; Calvo, R.; Conroy, P.W.; Klein, C.M.; Mellers, J.E.

    1990-01-01

    Today's economics dictate that nuclear power operational costs be contained by addressing frequently-occurring trips that might be minimized or avoided via specific upgrades. Much recent attention has focused on the significant percentage of plant trips related to feedwater flow regulation; however, another frequent feedwater-related trip stems from the loss of a single main feedwater pump while operating at high power levels, causing a plant trip on low steam generator water-level. This paper summarizes the results of several plant-specific studies that evaluate a unit's capabilities to consistently survive the loss of a main feedwater pump from full power, and outlines a methodology for analyzing this capability

  10. Coil geometry models for power loss analysis and hybrid inductive ...

    Indian Academy of Sciences (India)

    CHANDRASEKHARAN NATARAJ

    2018-04-26

    Apr 26, 2018 ... most of the WPT systems, but often suffers from power loss in the near field area of inductively coupled ... applications in the area of Distribution Generation (DG) ... embedded sensors, and buried devices, work at low voltage.

  11. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Chang Hyun; Ha, Sang Jun [KHNP CRI, Daejeon (Korea, Republic of); Han, Kee Soo [Nuclear Engineering Service and Solution (NESS) Co. Ltd., Deajeon (Korea, Republic of); Park, Chan Eok [KEPCO Engineering and Constructd., Deajeon (Korea, Republic of)

    2016-10-15

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings.

  12. Assessment of Coping Capability of KORI Unit 1 under Extended Loss AC Power and Loss of Ultimate Heat Sink Initiated by Beyond Design Natural Disaster

    International Nuclear Information System (INIS)

    Kim, Chang Hyun; Ha, Sang Jun; Han, Kee Soo; Park, Chan Eok

    2016-01-01

    In Korea, the government and industry performed comprehensive safety inspection on all domestic nuclear power plants against beyond design basis external events and fifty action items have been issued. In addition to post- Fukushima action items, the stress tests for all domestic nuclear power plants are on the way to enhance the safety of domestic nuclear power plants through finding the vulnerabilities in intentional stress conditions initiated by beyond design natural disaster. This paper presents assessment results of coping capability of KORI Unit 1 under the simultaneous Extended Loss of AC Power (ELAP) and Loss of Ultimate Heat Sink (LUHS) which is a representative plant condition initiated by beyond design natural disaster. The assessment of the coping capability of KORI Unit 1 has been performed under simultaneous the extended loss of AC power and loss of ultimate heat sink initiated by beyond design natural disaster. It is concluded that KORI Unit 1 has the capability, in the event of loss of safety functions by beyond design natural disaster, to sufficiently cool down the reactor core without fuel damage, to keep pressure boundaries of the reactor coolant system in transient condition and to control containment and temperature to maintain the integrity of the containment buildings

  13. Analysis of power loss data for the 200 Area Tank Farms in support of K Basin SAR work

    International Nuclear Information System (INIS)

    Shultz, M.V. Jr.

    1994-12-01

    An analysis of power loss data for the 200 Area Tank Farms was performed in support of K Basin safety analysis report work. The purpose of the analysis was to establish a relationship between the length of a power outage and its yearly frequency. This relationship can be used to determine whether the duration of a specific power loss is a risk concern. The information was developed from data contained in unusual occurrence reports (UORs) spanning a continuous period of 19.75 years. The average frequency of power loss calculated from the UOR information is 1.22 events per year. The mean of the power loss duration is 32.5 minutes an the median duration is 2 minutes. Nine events resulted in loss of power to both 200 East and 200 West areas simultaneously. Seven events (not necessarily the same events that resulted in loss of power to both 200 areas) resulted in outage durations exceeding 5 minutes. Approximately one-half of the events were caused by human error. The other half resulted from natural phenomena or equipment failures. None of the outages were reported to have any adverse effect on the tank farms

  14. High-current power supply for accelerator magnets

    International Nuclear Information System (INIS)

    Bourkland, K.R.; Winje, R.A.

    1978-01-01

    A power supply for controlling the current to accelerator magnets produces a high current at a precisely controlled time rate of change by varying the resonant frequency of an RLC circuit that includes the magnet and applying the current to the magnet during a predetermined portion of the waveform of an oscillation. The current is kept from going negative despite the reverse-current characteristics of thyristors by a quenching circuit

  15. Fuzzy Adaptive Particle Swarm Optimization for Power Loss Minimisation in Distribution Systems Using Optimal Load Response

    DEFF Research Database (Denmark)

    Hu, Weihao; Chen, Zhe; Bak-Jensen, Birgitte

    2014-01-01

    Consumers may decide to modify the profile of their demand from high price periods to low price periods in order to reduce their electricity costs. This optimal load response to electricity prices for demand side management generates different load profiles and provides an opportunity to achieve...... power loss minimization in distribution systems. In this paper, a new method to achieve power loss minimization in distribution systems by using a price signal to guide the demand side management is proposed. A fuzzy adaptive particle swarm optimization (FAPSO) is used as a tool for the power loss...

  16. Evaluating the effect placement capacitor and distributed photovoltaic generation for power system losses minimization in radial distribution system

    Science.gov (United States)

    Rahman, Yuli Asmi; Manjang, Salama; Yusran, Ilham, Amil Ahmad

    2018-03-01

    Power loss minimization have many advantagess to the distribution system radial among others reduction of power flow in feeder lines, freeing stress on feeder loading, deterrence of power procurement from the grid and also the cost of loss compensating instruments. This paper, presents capacitor and photovoltaic (PV) placement as alternative means to decrease power system losses. The paper aims to evaluate the best alternative for decreasing power system losses and improving voltage profile in the radial distribution system. To achieve the objectives of paper, they are used three cases tested by Electric Transient and Analysis Program (ETAP) simulation. Firstly, it performs simulation of placement capacitor. Secondly, simulated placement of PV. Lastly, it runs simulation of placement capacitor and PV simultaneously. The simulations were validated using the IEEE 34-bus test system. As a result, they proved that the installation of capacitor and PV integration simultaneously leading to voltage profile correction and power losses minimization significantly.

  17. Leakage and Power Loss Test Results for Competing Turbine Engine Seals

    National Research Council Canada - National Science Library

    Proctor, Margaret

    2004-01-01

    .... To address engine manufacturers' concerns about the heat generation and power loss from these contacting seals, brush, finger, and labyrinth seals were tested in the NASA High Speed, High Temperature...

  18. Losses Analysis of Different Grounding Schemes for Transformer-less Wind Turbine with Full-Scale Power Converter

    DEFF Research Database (Denmark)

    Sztykiel, Michal; Teodorescu, Remus; Munk-Nielsen, Stig

    2013-01-01

    Following work examines IGBT power loss and temperature distribution with regard to specific grounding method for the future concept of transformer-less offshore wind turbine. Analysis is performed via steady-state IGBT power loss estimator, which is made based on averaging of repetitive pulse...... cycles. Obtained results are validated with the experimental test set-up consisting of high power IGBTs....

  19. Application of Hybrid HS and Tabu Search Algorithm for Optimal Location of FACTS Devices to Reduce Power Losses in Power Systems

    Directory of Open Access Journals (Sweden)

    Z. Masomi Zohrabad

    2016-12-01

    Full Text Available Power networks continue to grow following the annual growth of energy demand. As constructing new energy generation facilities bears a high cost, minimizing power grid losses becomes essential to permit low cost energy transmission in larger distances and additional areas. This study aims to model an optimization problem for an IEEE 30-bus power grid using a Tabu search algorithm based on an improved hybrid Harmony Search (HS method to reduce overall grid losses. The proposed algorithm is applied to find the best location for the installation of a Unified Power Flow Controller (UPFC. The results obtained from installation of the UPFC in the grid are presented by displaying outputs.

  20. Review of reactive power dispatch strategies for loss minimization in a DFIG-based wind farm

    DEFF Research Database (Denmark)

    Zhang, Baohua; Hu, Weihao; Hou, Peng

    2017-01-01

    power control strategies are investigated. All of the combined strategies are formulated based on the comprehensive loss models of WFs, including the loss models of DFIGs, converters, filters, transformers, and cables of the collection system. Optimization problems are solved by a Modified Particle......This paper reviews and compares the performance of reactive power dispatch strategies for the loss minimization of Doubly Fed Induction Generator (DFIG)-based Wind Farms (WFs). Twelve possible combinations of three WF level reactive power dispatch strategies and fourWind Turbine (WT) level reactive...... Swarm Optimization (MPSO) algorithm. The effectiveness of these strategies is evaluated by simulations on a carefully designed WF under a series of cases with different wind speeds and reactive power requirements of the WF. The wind speed at each WT inside the WF is calculated using the Jensen wake...

  1. Development of Interior Permanent Magnet Motors with Concentrated Windings for Reducing Magnet Eddy Current Loss

    Science.gov (United States)

    Yamazaki, Katsumi; Kanou, Yuji; Fukushima, Yu; Ohki, Shunji; Nezu, Akira; Ikemi, Takeshi; Mizokami, Ryoichi

    In this paper, we present the development of interior magnet motors with concentrated windings, which reduce the eddy current loss of the magnets. First, the mechanism of the magnet eddy current loss generation is investigated by a simple linear magnetic circuit. Due to the consideration, an automatic optimization method using an adaptive finite element method is carried out to determine the stator and rotor shapes, which decrease the eddy current loss of the magnet. The determined stator and rotor are manufactured in order to proof the effectiveness by the measurement.

  2. AC Loss Analysis of MgB2-Based Fully Superconducting Machines

    Science.gov (United States)

    Feddersen, M.; Haran, K. S.; Berg, F.

    2017-12-01

    Superconducting electric machines have shown potential for significant increase in power density, making them attractive for size and weight sensitive applications such as offshore wind generation, marine propulsion, and hybrid-electric aircraft propulsion. Superconductors exhibit no loss under dc conditions, though ac current and field produce considerable losses due to hysteresis, eddy currents, and coupling mechanisms. For this reason, many present machines are designed to be partially superconducting, meaning that the dc field components are superconducting while the ac armature coils are conventional conductors. Fully superconducting designs can provide increases in power density with significantly higher armature current; however, a good estimate of ac losses is required to determine the feasibility under the machines intended operating conditions. This paper aims to characterize the expected losses in a fully superconducting machine targeted towards aircraft, based on an actively-shielded, partially superconducting machine from prior work. Various factors are examined such as magnet strength, operating frequency, and machine load to produce a model for the loss in the superconducting components of the machine. This model is then used to optimize the design of the machine for minimal ac loss while maximizing power density. Important observations from the study are discussed.

  3. Analysis of HFETR shut-down state caused by loss of off-site power supply

    International Nuclear Information System (INIS)

    Wang Jinghu

    1997-01-01

    During the last 15 years, there are more than 40 unplanned shut-downs caused by loss of off-site power in HFETR. Because HFETR is a special research reactor, the author describes the shut-down state as three period. The author also discusses the influence of the number of shut-down due to loss of off-site power supply on the reactor safety, and propose some suggestions and measures to reduce the effects

  4. Cochlear Outer-Hair-Cell Power Generation and Viscous Fluid Loss

    Science.gov (United States)

    Wang, Yanli; Steele, Charles R.; Puria, Sunil

    2016-01-01

    Since the discovery of otoacoustic emissions and outer hair cell (OHC) motility, the fundamental question of whether the cochlea produces mechanical power remains controversial. In the present work, direct calculations are performed on power loss due to fluid viscosity and power generated by the OHCs. A three-dimensional box model of the mouse cochlea is used with a feed-forward/feed-backward approximation representing the organ of Corti cytoarchitecture. The model is fit to in vivo basilar membrane motion with one free parameter for the OHCs. The calculations predict that the total power output from the three rows of OHCs can be over three orders of magnitude greater than the acoustic input power at 10 dB sound pressure level (SPL). While previous work shows that the power gain, or the negative damping, diminishes with intensity, we show explicitly based on our model that OHC power output increases and saturates with SPL. The total OHC power output is about 2 pW at 80 dB SPL, with a maximum of about 10 fW per OHC.

  5. A Practical Core Loss Model for Filter Inductors of Power Electronic Converters

    DEFF Research Database (Denmark)

    Matsumori, Hiroaki; Shimizu, Toshihisa; Wang, Xiongfei

    2018-01-01

    This paper proposes a core loss model for filter inductors of power electronic converters. The model allows a computationally efficient analysis on the core loss of the inductor under the square voltage excitation and the premagnetization condition. First, the core loss of the filter inductor under...... buck chopper excitation is evaluated with the proposed model and compared with the conventional methods. The comparison shows that the proposed method results in a better core loss prediction under the premagnetized condition than that of conventional alternatives. Then, the core loss of the filter...... inductor with the pulsewidth modulated inverter excitation is evaluated, which shows that the proposed model not only accurately predicts the core loss but also identifies the hysteresis loss part. These results demonstrate that the approach can further be used for the development of magnetic materials...

  6. Study of structure of HTS coated conductor with ferromagnetic substrate having low AC transport current loss using FEM

    International Nuclear Information System (INIS)

    Miyagi, D.; Amadutsumi, Y.; Takahashi, N.; Tsukamoto, O.

    2007-01-01

    AC transport current losses of coated conductors with ferromagnetic substrates are higher than the loss calculated by the Norris equation. In order to reduce the AC transport current loss we propose in this paper a structure of the coated conductor that has wider substrate than the SC (Superconducting) layer. The current distribution and AC loss of the proposed model are analyzed by means of FEM. The AC transport current loss is reduced due to the change of current density distribution near the edge of SC layer, consequent to the high value of magnetic permeability of the ferromagnetic substrate, that is wider than the SC layer

  7. Current status of nuclear power

    International Nuclear Information System (INIS)

    Behnke, W.B.

    1984-01-01

    The decision to devote the 1984 conference to nuclear power is timely and appropriate. Illinois has a long, and distinguished history in the development of civilian nuclear power. The concept was born at the University of Chicago, developed at Argonne National Laboratory and demonstrated on the Commonwealth Edison system at our pioneer Dresden Nuclear Station. Today, Illinois ranks number one in the nation in nuclear generation. With over a quarter century of commercial operating experience, nuclear power has proven its worth and become a significant and growing component of electric power supply domestically and throughout the world. Despite its initial acceptance, however, the nuclear power industry in the U.S. is now in the midst of a difficult period of readjustment stemming largely from the economic and regulatory problems of the past decade. As a result, the costs of plants under construction have increased dramatically, causing serious financial difficulties for several projects and their owners. At the same time, the U.S. is facing hard choices concerning its future energy supplies. Conferences such as this have an important role in clarifying the issues and helping to find solutions to today's pressing energy problems. This paper summarizes the status of nuclear power both here and abroad, discussing the implications of current events in the context of national energy policy and economic development here in Illinois

  8. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J. J.; van der Meiden, H. J.; Morgan, T. W.; D.C. Schram,; De Temmerman, G.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 mu F) is parallel-coupled to the current regulated power supply. The current is transiently increased from

  9. Characterization of a high-power/current pulsed magnetized arc discharge

    NARCIS (Netherlands)

    Zielinski, J.J.; Meiden, van der H.J.; Morgan, T.W.; Schram, D.C.; De Temmerman, G.C.

    2012-01-01

    A high-power pulsed magnetized arc discharge has been developed to allow the superimposition of a dc plasma and a high-power plasma impulse with a single plasma source. A capacitor bank (8400 µF) is parallel-coupled to the current regulated power supply. The current is transiently increased from its

  10. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportio......This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional......-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions....... First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results...

  11. Emotion regulation reduces loss aversion and decreases amygdala responses to losses.

    Science.gov (United States)

    Sokol-Hessner, Peter; Camerer, Colin F; Phelps, Elizabeth A

    2013-03-01

    Emotion regulation strategies can alter behavioral and physiological responses to emotional stimuli and the neural correlates of those responses in regions such as the amygdala or striatum. The current study investigates the brain systems engaged when using an emotion regulation technique during financial decisions. In decision making, regulating emotion with reappraisal-focused strategies that encourage taking a different perspective has been shown to reduce loss aversion as observed both in choices and in the relative arousal responses to actual loss and gain outcomes. In the current study, we find using fMRI that behavioral loss aversion correlates with amygdala activity in response to losses relative to gains. Success in regulating loss aversion also correlates with the reduction in amygdala responses to losses but not to gains. Furthermore, across both decisions and outcomes, we find the reappraisal strategy increases baseline activity in dorsolateral and ventromedial prefrontal cortex and the striatum. The similarity of the neural circuitry observed to that seen in emotion regulation, despite divergent tasks, serves as further evidence for a role of emotion in decision making, and for the power of reappraisal to change assessments of value and thereby choices.

  12. Computing Active Power Losses Using a Mathematical Model of a Regulated Street Luminaire

    Directory of Open Access Journals (Sweden)

    Roman Sikora

    2018-05-01

    Full Text Available Before the use of regulated street luminaires with variable power and luminous flux, computations were performed using constant values for their electrical and photometric parameters. At present, where such lighting is in use, it is no longer possible to base calculations on such assumptions. Computations of energy and power losses, for example, need to be performed for all dimming levels and based on the applied regulation algorithm. Based on measurements carried out on regulated luminaires, it was found that certain electrical parameters have a nonlinear dependence on the dimming level. Electrical parameters were also observed to depend on the value of the supply voltage. The results of the measurements are presented in this article. Failure to take account of power losses in computations of the energy efficiency of street lighting in accordance with the applicable EN 13201 standard causes values of energy efficiency indicators to be overstated. Power loss computations are presented in this article for a sample street lighting system with regulated luminaires, for the whole range of dimming levels and additionally for fluctuations of ±10% in the supply voltage. In addition, a mathematical model of a regulated luminaire is constructed with the use of regression methods, and a practical application of that model is described.

  13. Distribution grid reconfiguration reduces power losses and helps integrate renewables

    International Nuclear Information System (INIS)

    Lueken, Colleen; Carvalho, Pedro M.S.; Apt, Jay

    2012-01-01

    A reconfigurable network can change its topology by opening and closing switches on power lines. We use real wind, solar, load, and cost data and a model of a reconfigurable distribution grid to show that reconfiguration allows a grid operator to reduce operational losses as well as to accept more intermittent renewable generation than a static configuration can. Net present value analysis of automated switch technology shows that the return on investment is negative for this test network when considering only loss reduction, but that the investment is attractive under certain conditions when reconfiguration is used to minimize curtailment. - Highlights: ► Reconfiguration may reduce losses in grids with solar or wind distributed generation. ► Reconfigurable networks can accept more solar or wind DG than static ones. ► Using reconfiguration for loss reduction would not create a positive ROI. ► Using reconfiguration to reduce curtailment usually would create a positive ROI.

  14. Adiabatic energization in the ring current and its relation to other source and loss terms

    Science.gov (United States)

    Liemohn, M. W.; Kozyra, J. U.; Clauer, C. R.; Khazanov, G. V.; Thomsen, M. F.

    2002-04-01

    The influence of adiabatic energization and deenergization effects, caused by particle drift in radial distance, on ring current growth rates and loss lifetimes is investigated. Growth and loss rates from simulation results of four storms (5 June 1991, 15 May 1997, 19 October 1998, and 25 September 1998) are examined and compared against the y component of the solar wind electric field (Ey,sw). Energy change rates with and without the inclusion of adiabatic energy changes are considered to isolate the influence of this mechanism in governing changes of ring current strength. It is found that the influence of adiabatic drift effects on the energy change rates is very large when energization and deenergization are considered separately as gain and loss mechanisms, often about an order of magnitude larger than all other source or loss terms combined. This is true not only during storm times, when the open drift path configuration of the hot ions dominates the physics of the ring current, but also during quiet times, when the small oscillation in L of the closed trajectories creates a large source and loss of energy each drift orbit. However, the net energy change from adiabatic drift is often smaller than other source and loss processes, especially during quiet times. Energization from adiabatic drift dominates ring current growth only during portions of the main phase of storms. Furthermore, the net-adiabatic energization is often positive, because some particles are lost in the inner magnetosphere before they can adiabatically deenergize. It is shown that the inclusion of only this net-adiabatic drift effect in the total source rate or loss lifetime (depending on the sign of the net-adiabatic energization) best matches the observed source and loss values from empirical Dst predictor methods (that is, for consistency, these values should be compared between the calculation methods). While adiabatic deenergization dominates the loss timescales for all Ey,sw values

  15. Conflict nuclear power. Theses for current supply with and without nuclear power

    International Nuclear Information System (INIS)

    Schwarz, E.

    2007-01-01

    In the context of a lecture at the 2nd Internationally Renewable Energy Storage Conference at 19th to 21st November, 2007, in Bonn (Federal Republic of Germany), the author of the contribution under consideration reports on theses for current supply with and without nuclear power. (1) Theses for current supply with nuclear energy: Due to a relative amount of 17 % of nuclear energy in the world-wide energy production and due to the present reactor technology, the supplies of uranium amount nearly 50 to 70 years. The security of the nuclear power stations is controversially judged in the public and policy. In a catastrophic accident in a nuclear power station, an amount of nearly 2.5 billion Euro is available for adjustment of damages (cover note). The disposal of radioactive wastes is not solved anywhere in the world. The politically demanded separation between military and civilian use of the nuclear energy technology is not possible. The exit from the nuclear energy is fixed in the atomic law. By any means, the Federal Republic of Germany is not insulated in the European Union according to its politics of nuclear exit. After legal adjustment of the exit from the nuclear energy the Federal Republic of Germany should unfold appropriate activities for the re-orientation of Euratom, Nuclear Energy Agency and the International Atomic Energy Agency. The consideration of the use of nuclear energy in relation to the risks has to result that its current kind of use is not acceptable and to be terminated as fast as possible. (2) Theses for current supply without nuclear energy: The scenario technology enables a transparency of energy future being deliverable for political decisions. In accordance with this scenario, the initial extra costs of the development of the renewable energies and the combined heat and power generation amount approximately 4 billion Euro per year. The conversion of the power generation to renewable energies and combined heat and power generation

  16. Losses and Inductive Parameters in Subsea Power Cables

    OpenAIRE

    Stølan, Ronny

    2009-01-01

    Four samples of galvanized steel armour for sub sea power cables are tested with an electric steel tester. The samples exhibit different remanence magnetization and permeability. The effects of permeability on loss in sub sea cables is found to be insignificant. Slight increase of conductor inductance due to increase in permeability of armour wires is observed. Mutual cancellation of inductance between circuits that are twisted opposite to each other, or with respect to one circuit, is confir...

  17. Power-law ansatz in complex systems: Excessive loss of information

    Science.gov (United States)

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  18. Power-law ansatz in complex systems: Excessive loss of information.

    Science.gov (United States)

    Tsai, Sun-Ting; Chang, Chin-De; Chang, Ching-Hao; Tsai, Meng-Xue; Hsu, Nan-Jung; Hong, Tzay-Ming

    2015-12-01

    The ubiquity of power-law relations in empirical data displays physicists' love of simple laws and uncovering common causes among seemingly unrelated phenomena. However, many reported power laws lack statistical support and mechanistic backings, not to mention discrepancies with real data are often explained away as corrections due to finite size or other variables. We propose a simple experiment and rigorous statistical procedures to look into these issues. Making use of the fact that the occurrence rate and pulse intensity of crumple sound obey a power law with an exponent that varies with material, we simulate a complex system with two driving mechanisms by crumpling two different sheets together. The probability function of the crumple sound is found to transit from two power-law terms to a bona fide power law as compaction increases. In addition to showing the vicinity of these two distributions in the phase space, this observation nicely demonstrates the effect of interactions to bring about a subtle change in macroscopic behavior and more information may be retrieved if the data are subject to sorting. Our analyses are based on the Akaike information criterion that is a direct measurement of information loss and emphasizes the need to strike a balance between model simplicity and goodness of fit. As a show of force, the Akaike information criterion also found the Gutenberg-Richter law for earthquakes and the scale-free model for a brain functional network, a two-dimensional sandpile, and solar flare intensity to suffer an excessive loss of information. They resemble more the crumpled-together ball at low compactions in that there appear to be two driving mechanisms that take turns occurring.

  19. Drag and power-loss in rowing due to velocity fluctuations

    NARCIS (Netherlands)

    Greidanus, A.J.; Delfos, R.; Westerweel, J.; Jansen, A.J.

    2016-01-01

    The flow motions in the turbulent boundary layer between water and a rowing boat initiate a turbulent skin friction. Reducing this skin friction results in better rowing performances. A Taylor-Couette (TC) facility was used to verify the power losses due to velocity fluctuations PV′ in

  20. Low loss power splitter for antenna beam forming networks using probes in a waveguide

    DEFF Research Database (Denmark)

    Dich, Mikael; Mortensen, Mette Dahl

    1994-01-01

    The design of a low loss one-to-four power splitter suitable for beam forming networks in antenna arrays is presented. The power splitter is constructed of a shorted waveguide in which five coaxial probes are inserted. Methods for the design of the power splitter are presented together...

  1. Optimization Criteria of Power Transformer Operation

    Directory of Open Access Journals (Sweden)

    A. A. Gonchar

    2006-01-01

    Full Text Available It has been shown that minimum losses in active power of a power transformer do not correspond to its maximum efficiency. For a transformer being operated there are no so called «zones of its economical operation». In this case strictly specified value of active power losses corresponds to a particular current of the winding.

  2. Current fusion power plant design concepts

    International Nuclear Information System (INIS)

    Gore, B.F.; Murphy, E.S.

    1976-09-01

    Nine current U.S. designs for fusion power plants are described in this document. Summary tabulations include a tenth concept, for which the design document was unavailable during preparation of the descriptions. The information contained in the descriptions was used to define an envelope of fusion power plant characteristics which formed the basis for definition of reference first commercial fusion power plant design. A brief prose summary of primary plant features introduces each of the descriptions contained in the body of this document. In addition, summary tables are presented. These tables summarize in side-by-side fashion, plant parameters, processes, combinations of materials used, requirements for construction materials, requirements for replacement materials during operation, and production of wastes

  3. Probabilistic Power Flow Simulation allowing Temporary Current Overloading

    NARCIS (Netherlands)

    W.S. Wadman (Wander); G. Bloemhof; D.T. Crommelin (Daan); J.E. Frank (Jason)

    2012-01-01

    htmlabstractThis paper presents a probabilistic power flow model subject to connection temperature constraints. Renewable power generation is included and modelled stochastically in order to reflect its intermittent nature. In contrast to conventional models that enforce connection current

  4. Probablistic Power Flow Simulations Allowing Temporary Current Overloading

    NARCIS (Netherlands)

    Wadman, W.; Bloemhof, G.; Crommelin, D.; Frank, J.; Ozdemir, A.

    2013-01-01

    This paper presents a probabilistic power flow model subject to connection temperature constraints. Renewable power generation is included and modelled stochastically in order to reflect its intermittent nature. In contrast to conventional models that enforce connection current constraints,

  5. A robust low quiescent current power receiver for inductive power transmission in bio implants

    Science.gov (United States)

    Helalian, Hamid; Pasandi, Ghasem; Jafarabadi Ashtiani, Shahin

    2017-05-01

    In this paper, a robust low quiescent current complementary metal-oxide semiconductor (CMOS) power receiver for wireless power transmission is presented. This power receiver consists of three main parts including rectifier, switch capacitor DC-DC converter and low-dropout regulator (LDO) without output capacitor. The switch capacitor DC-DC converter has variable conversion ratios and synchronous controller that lets the DC-DC converter to switch among five different conversion ratios to prevent output voltage drop and LDO regulator efficiency reduction. For all ranges of output current (0-10 mA), the voltage regulator is compensated and is stable. Voltage regulator stabilisation does not need the off-chip capacitor. In addition, a novel adaptive biasing frequency compensation method for low dropout voltage regulator is proposed in this paper. This method provides essential minimum current for compensation and reduces the quiescent current more effectively. The power receiver was designed in a 180-nm industrial CMOS technology, and the voltage range of the input is from 0.8 to 2 V, while the voltage range of the output is from 1.2 to 1.75 V, with a maximum load current of 10 mA, the unregulated efficiency of 79.2%, and the regulated efficiency of 64.4%.

  6. Protection of power transformers against geomagnetically induced currents

    Directory of Open Access Journals (Sweden)

    Gurevich Vladimir

    2011-01-01

    Full Text Available The article examines the problem of saturation and failure of power transformers under geomagnetically induced currents and currents of the E3 component of high-altitude nuclear explosions. It also describes a special protective relay reacting on DC component in the transformer neutral current.

  7. Class H power amplifier for power saving in fluxgate current transducers

    OpenAIRE

    Velasco Quesada, Guillermo; Román Lumbreras, Manuel; Pérez Delgado, Raul; Conesa Roca, Alfons

    2016-01-01

    This paper presents a new improvement in the design of a fluxgate-based current transducer in order to reduce the power consumption of control electronics. The proposed improvement involves the replacement of the output linear amplifier of the transducer by a class H amplifier. The output amplifier is devoted to the magnetic flux compensation and generates the transducer output current, which is proportional to the current to be measured. In this way, it is possible to reduce significantly th...

  8. Effect of iron content on permeability and power loss characteristics ...

    Indian Academy of Sciences (India)

    Administrator

    have been measured by vibrating sample magnetometer (VSM). The permeability of cadmium doped lithium ferrites exhibited higher values than zinc doped lithium ferrites. The power loss of cadmium doped lithium ferrites is lesser as compared to zinc doped lithium ferrites in the frequency range of 50–5000 kHz and at flux.

  9. Power Loss Analysis and Comparison of Segmented and Unsegmented Energy Coupling Coils for Wireless Energy Transfer.

    Science.gov (United States)

    Tang, Sai Chun; McDannold, Nathan J

    2015-03-01

    This paper investigated the power losses of unsegmented and segmented energy coupling coils for wireless energy transfer. Four 30-cm energy coupling coils with different winding separations, conductor cross-sectional areas, and number of turns were developed. The four coils were tested in both unsegmented and segmented configurations. The winding conduction and intrawinding dielectric losses of the coils were evaluated individually based on a well-established lumped circuit model. We found that the intrawinding dielectric loss can be as much as seven times higher than the winding conduction loss at 6.78 MHz when the unsegmented coil is tightly wound. The dielectric loss of an unsegmented coil can be reduced by increasing the winding separation or reducing the number of turns, but the power transfer capability is reduced because of the reduced magnetomotive force. Coil segmentation using resonant capacitors has recently been proposed to significantly reduce the operating voltage of a coil to a safe level in wireless energy transfer for medical implants. Here, we found that it can naturally eliminate the dielectric loss. The coil segmentation method and the power loss analysis used in this paper could be applied to the transmitting, receiving, and resonant coils in two- and four-coil energy transfer systems.

  10. Design and construction of a high-stability, low-noise power supply for use with high-resolution electron energy loss spectrometers

    International Nuclear Information System (INIS)

    Katz, J.E.; Davies, P.W.; Crowell, J.E.; Somorjai, G.A.

    1982-01-01

    The design and construction of a high-stability, low-noise power supply which provides potentials for the lens and analyzer elements of a 127 0 Ehrhardt-type high-resolution electron energy loss spectrometer (HREELS) is described. The supply incorporates a filament emission-control circuit and facilities for measuring electron beam current at each spectrometer element, thus facilitating optimal tuning of the spectrometer. Spectra obtained using this supply are shown to have a four-fold improvement in signal-to-noise ratio and a higher resolution of the vibrational loss features when compared with spectra taken using a previously existing supply based on passive potential divider networks

  11. Transient characteristics of current lead losses for the large scale high-temperature superconducting rotating machine

    International Nuclear Information System (INIS)

    Le, T. D.; Kim, J. H.; Park, S. I.; Kim, D. J.; Kim, H. M.; Lee, H. G.; Yoon, Y. S.; Jo, Y. S.; Yoon, K. Y.

    2014-01-01

    To minimize most heat loss of current lead for high-temperature superconducting (HTS) rotating machine, the choice of conductor properties and lead geometry - such as length, cross section, and cooling surface area - are one of the various significant factors must be selected. Therefore, an optimal lead for large scale of HTS rotating machine has presented before. Not let up with these trends, this paper continues to improve of diminishing heat loss for HTS part according to different model. It also determines the simplification conditions for an evaluation of the main flux flow loss and eddy current loss transient characteristics during charging and discharging period.

  12. High RF power test of a CFC antenna module for lower hybrid current drive

    International Nuclear Information System (INIS)

    Maebara, S.; Seki, M.; Ikeda, Y.; Kiyono, K.; Suganuma, K.; Imai, T.; Goniche, M.; Bibet, Ph.; Brossaud, J.; Cano, V.; Kazarian-Vibert, F.; Froissard, P.; Rey, G.

    1998-01-01

    A mock-up of a 3.7 GHz Lower Hybrid Current Drive (LHCD) antenna module was fabricated from Carbon Fibre Composite (CFC) for the development of heat resistive low Z front facing the plasma. This 2 divided waveguide module is made from CFC plates and rods which are Cu-plated to reduce the RF losses. The withstand-voltage, the RF properties and the outgassing rates for long pulses and high RF power were tested at the Lower Hybrid test bed facility of Cadarache. A reference module made from Dispersion Strengthened Copper (DSC) was also fabricated. After the short pulse conditioning, long pulses with a power density ranging between 50 and 150 MW/m 2 were performed with no breakdowns on the CFC module. It was also checked that the highest power density, up to 150 MW/m 2 , could be transmitted when the waveguides are filled with H2 at a pressure of 5 x 10 -2 Pa. During a long pulse, the power reflection coefficient remains low in the 0.8-1.3 % range and no significant change in the reflection coefficient is measured after the thermal cycling provided by the long pulse operation. From thermocouple measurements, RF losses of the copper coated CFC and the DSC modules were compared. No significant differences were measured. From pressure measurements, it was found that the outgassing rate of Cu-plated CFC is about 6-7 times larger than of DSC at 300 deg.C. It is concluded that a CFC module is an attractive candidate for the hardening of the tip of the LHCD antenna. (author)

  13. Low loss power splitter for antenna beam forming networks using probes in a waveguide

    OpenAIRE

    Dich, Mikael; Mortensen, Mette Dahl

    1994-01-01

    The design of a low loss one-to-four power splitter suitable for beam forming networks in antenna arrays is presented. The power splitter is constructed of a shorted waveguide in which five coaxial probes are inserted. Methods for the design of the power splitter are presented together with an experimental verification

  14. Analytical evaluation on loss of off-side electric power simulation of the High Temperature Engineering Test Reactor

    International Nuclear Information System (INIS)

    Takeda, Takeshi; Nakagawa, Shigeaki; Tachibana, Yukio; Takada, Eiji; Kunitomi, Kazuhiko

    2000-03-01

    A rise-to-power test of the high temperature engineering test reactor (HTTR) started on September 28 in 1999 for establishing and upgrading the technological basis for the high temperature gas-cooled reactor (HTGR). A loss of off-site electric power test of the HTTR from the normal operation under 15 and 30 MW thermal power will be carried out in the rise-to-power test. Analytical evaluations on transient behaviors of the reactor and plant during the loss of off-site electric power were conducted. These estimations are proposed as benchmark problems for the IAEA coordinated research program on 'Evaluation of HTGR Performance'. This report describes an event scenario of transient during the loss of off-site electric power, the outline of major components and system, detailed thermal and nuclear data set for these problems and pre-estimation results of the benchmark problems by an analytical code 'ACCORD' for incore and plant dynamics of the HTGR. (author)

  15. Determination of the Real Loss of Power for a Condensing and a Backpressure Turbine by Means of Second Law Analysis

    Directory of Open Access Journals (Sweden)

    Henrik Holmberg

    2009-10-01

    Full Text Available All real processes generate entropy and the power/exergy loss is usually determined by means of the Gouy-Stodola law. If the system only exchanges heat at the environmental temperature, the Gouy-Stodola law gives the correct loss of power. However, most industrial processes exchange heat at higher or lower temperatures than the actual environmental temperature. When calculating the real loss of power in these cases, the Gouy-Stodola law does not give the correct loss if the actual environmental temperature is used. The first aim of this paper is to show through simple steam turbine examples that the previous statement is true. The second aim of the paper is to define the effective temperature to calculate the real power loss of the system with the Gouy-Stodola law, and to apply it to turbine examples. Example calculations also show that the correct power loss can be defined if the effective temperature is used instead of the real environmental temperature.

  16. Power losses in the international linear collider 20 mrad extraction ...

    Indian Academy of Sciences (India)

    2Stanford Linear Accelerator Center, USA. ∗E-mail: ferrari@tsl.uu.se. Abstract. We have performed a detailed study of the power losses in the post-collision extraction line of a TeV e+e− collider with a crossing angle of 20 mrad at the interaction point. Five cases were considered: four luminosity configurations for ILC and ...

  17. Direct Drive Generator for Renewable Power Conversion from Water Currents

    International Nuclear Information System (INIS)

    Segergren, Erik

    2005-01-01

    In this thesis permanent magnet direct drive generator for power conversion from water currents is studied. Water currents as a power source involves a number of constrains as well as possibilities, especially when direct drive and permanent magnets are considered. The high power fluxes and low current velocities of a water current, in combination with its natural variations, will affect the way the generator is operated and, flowingly, the appearance of the generator. The work in this thesis can, thus, be categorized into two general topics, generator technology and optimization. Under the first topic, fundamental generator technology is used to increase the efficiency of a water current generator. Under the latter topic, water current generators are optimized to a specific environment. The conclusion drawn from this work is that it is possible to design very low speed direct drive generators with good electromagnetic properties and wide efficiency peak

  18. Effect of iron content on permeability and power loss characteristics of

    Indian Academy of Sciences (India)

    Magnetic properties like saturation magnetization, coercivity, retentivity have been measured by vibrating sample magnetometer (VSM). The permeability of cadmium doped lithium ferrites exhibited higher values than zinc doped lithium ferrites. The power loss of cadmium doped lithium ferrites is lesser as compared to zinc ...

  19. A high-current, high-voltage power supply with special output current waveform for APS injector synchrotron dipole magnets

    International Nuclear Information System (INIS)

    Fathizadeh, M.; Despe, O.D.; McGhee, D.G.; Mills, F.E.; Turner, L.R.

    1991-01-01

    This paper describes a high-voltage, high-current power supply for the injector synchrotron dipole magnets at APS. In order to reset the dipole magnets in each cycle two different current waveforms are suggested. The first current waveform consists of three sections, namely: dc-reset, linear ramp, and recovery sections where injection is done ''on the fly''. The second current waveform consists of six different sections, dc-reset, transition to injection level, injection flat level, parabolic, linear ramp and recovery sections. The effect of such waveforms on the beam is discussed and the power supply limitations to follow such waveforms are given. The power supply limitations are due to the power components and control loops. The reference for the current loop is generated by a DAC which is discussed

  20. ESTIMATION OF DECREASING LOSSES OF ACTIVE POWER IN TRANSFORMERS IN SETTING BATTERY OF LOW-VOLTAGE CAPACITORS

    Directory of Open Access Journals (Sweden)

    V. N. Radkevich

    2014-01-01

    Full Text Available This paper describes an estimation method of decreasing losses of active power in power transformers with voltage 10(6/0,4 kV after installation of devices of reactive power compensation on output side depending on voltage level, connected to capacity devices, taking into account dielectric loss in capacitors. Analysis of functional dependences was carried out. Investigation of function with a help of derivations was carried out. Points of function extremum and also its intervals of rise and fall rates were founded. This paper describes graphic investigation of obtained functional dependence, which is introduced by quartic polynominal. It is established that decreasing of losses of active power depends on technical parameters and load factor of transformer, coefficient of loading power of electricity consumers, voltage value connected to capacitor unit.Using obtained functional dependences, calculations for the main size-types of power transformers with voltage 10(6/0,4 kV serie ТМГ 11 and ТМГ12 were done. It is established that depending on technical characteristics of certain transformer, coefficient of its loading and power, there is a definite value of deviation of real voltage value from working voltage of capacitor installation when it will be observed positive technical and economical effect from installed capacitor battery unit. For taken value of loading coefficient and transformer’s power the maximum decrease of losses of active power takes place under voltage directed to capacitor unit, which is lower then nominal value. For all taken size-types of power transformers the argument of investigating function for its maximal value is out of standard permissible of voltage deviations from nominal value.These functional dependents can be used for preliminary calculations, which are needed for making decision on compensation of reactive power in electric power supply systems of industrial objects. Their consideration allows more

  1. CrAlN coating to enhance the power loss and magnetostriction in grain oriented electrical steel

    Directory of Open Access Journals (Sweden)

    Vishu Goel

    2016-05-01

    Full Text Available Grain oriented electrical steels (GOES are coated with aluminium orthophosphate on top of a forsterite (Mg2SiO4 layer to provide stress and insulation resistance to reduce the power loss and magnetostriction. In this work Chromium Aluminium Nitride (CrAlN was coated on GOES samples with electron beam physical vapour deposition and was tested in the single strip and magnetostriction tester to measure the power loss and magnetostriction before and after coating. Power loss was reduced by 2% after coating and 6 % post annealing at 800 °C. For applied compressive stress of 6 MPa, the magnetostrictive strain was zero with the CrAlN coating as compared to 22 and 24 μϵ for fully finished GOES and GOES without phosphate coating. The thickness of the coating was found to be 1.9 ± 0.2 μm estimated with Glow Discharge Optical Emission Spectroscopy (GDOES. The magnetic domain imaging showed domain narrowing after coating. The reduction in power loss and magnetostriction was due to the large residual compressive stress and Young’s modulus (270 GPa of the coating.

  2. CrAlN coating to enhance the power loss and magnetostriction in grain oriented electrical steel

    Energy Technology Data Exchange (ETDEWEB)

    Goel, Vishu; Anderson, Philip; Hall, Jeremy [Wolfson Centre for Magnetics, Cardiff University, Cardiff- CF243AA (United Kingdom); Robinson, Fiona [Cogent power Ltd., Newport-NP190RB (United Kingdom); Bohm, Siva [Dept. of metallurgical engineering & materials science, IIT Bombay, Mumbai-400076 (India)

    2016-05-15

    Grain oriented electrical steels (GOES) are coated with aluminium orthophosphate on top of a forsterite (Mg{sub 2}SiO{sub 4}) layer to provide stress and insulation resistance to reduce the power loss and magnetostriction. In this work Chromium Aluminium Nitride (CrAlN) was coated on GOES samples with electron beam physical vapour deposition and was tested in the single strip and magnetostriction tester to measure the power loss and magnetostriction before and after coating. Power loss was reduced by 2% after coating and 6 % post annealing at 800 °C. For applied compressive stress of 6 MPa, the magnetostrictive strain was zero with the CrAlN coating as compared to 22 and 24 μϵ for fully finished GOES and GOES without phosphate coating. The thickness of the coating was found to be 1.9 ± 0.2 μm estimated with Glow Discharge Optical Emission Spectroscopy (GDOES). The magnetic domain imaging showed domain narrowing after coating. The reduction in power loss and magnetostriction was due to the large residual compressive stress and Young’s modulus (270 GPa) of the coating.

  3. SLIPPER PERFORMANCE INVESTIGATION IN AXIAL PISTON PUMPS AND MOTORS-FLOW AND VISCOUS POWER LOSSES

    Directory of Open Access Journals (Sweden)

    A. Osman KURBAN

    1997-01-01

    Full Text Available In this study, the slippers being the most effective on the performance of swash plate type axial piston pumps and motors, which is a good example of hydrodynamic-hydrostatic bearing applications, have been investigated. With respect to this, having derived the viscous moment loss, viscous flow leakage loss and power loss equations, the variations of these parameters under different operating conditions have been examined experimentally.

  4. Impact of Uncertainty on Calculations for Recovery from Loss of Offsite Power

    International Nuclear Information System (INIS)

    Kelly, Dana L.

    2010-01-01

    Uncertainty, both aleatory and epistemic, can have a significant impact on estimated probabilities of recovering from loss of offsite power within a specified time window, and such probabilities are an input to risk-informed decisions as to the significance of inspection findings in the U.S. Nuclear Regulatory Commission's Reactor Oversight Process. In particular, the choice of aleatory model for offsite power recovery time can have a significant impact on the estimated nonrecovery probability, especially if epistemic uncertainty regarding parameters in the aleatory model is accounted for properly. In past and current analyses, such uncertainty has largely been ignored. This paper examines the impact of both aleatory and epistemic uncertainty on the results, using modern open-source Bayesian inference software, which implements Markov chain Monte Carlo sampling. It includes examples of time-dependent convolution calculations to show the impact that uncertainty can have on this increasingly frequent type of calculation, also. The results show that the 'point estimate' result, which is an input to risk-informed decisions, can easily be uncertain by a factor of 10 if both aleatory and epistemic uncertainties are considered. The paper also illustrates the use of Bayesian model selection criteria to aid in the choice of aleatory model.

  5. THREE-PHASE ENERGY SUPPLY SYSTEMS SIMULATION FOR THE TOTAL POWER LOSSES COMPONENTS ASSESSMENT

    Directory of Open Access Journals (Sweden)

    D.V. Tugay

    2016-09-01

    Full Text Available Purpose. The goal is to optimize a structure of Matlab-model of the three-phase energy supply system with power active filter. The mathematical model that describes the energy supply system modes of operation which contains additional losses is proposed. Methodology. We have applied concepts of the electrical circuits theory, mathematical modeling elements based on linear algebra and vector calculus, mathematical simulation in Matlab package. Results. We have developed two models of three-phase energy supply system. The first one is based on a vector representation, and the second one on the matrix representation of energy processes. Using these models we have solved the problem of maintaining unchanged the average useful power for 279 cases of energy supply system modes of operation. Originality. We have developed methods of mathematical analysis of a three-phase energy supply systems with polyharmonic voltages and currents in the symmetric and asymmetric modes. Practical value. We have created Matlab-model of a three-phase energy supply system with automated calculation of a correction factor. It allows reducing more than one order the time for energy processes elucidation in multiphase systems.

  6. Design and RF test result of High Power Hybrid Combiner for Helicon Wave Current Drive in KSTAR Plasmas

    Energy Technology Data Exchange (ETDEWEB)

    Park, S. Y.; Kim, H. J.; Wi, H. H.; Wang, S. J.; Kwak, J. G. [NFRI, Daejeon (Korea, Republic of)

    2016-05-15

    200 kW RF power will be injected to plasmas through the traveling wave antenna after combining four klystrons output powers using three hybrid combiners. Each klystron produces 60 kW output at the frequency of 500 MHz. RF power combiners commonly used to divide or combine output powers for various rf and microwave applications. It is divided into several types according to the design type such as Wilkinson combiner, radial and quadrature hybrid combiner. We designed high power hybrid combiners using 6-1/8 inch coaxial line. The power combiner has many advantages such as high isolation, low insertion loss and high power handling capability. In this paper design and rf test results of high power combiners will be described. High power combiners using three coaxial hybrid couplers will be utilized for effectively combining of 500 MHz, 200 kW output powers generated by four klystrons. We have designed, fabricated, and tested a 6-1/8 inch coaxial hybrid combiners at 500 MHz for efficiently off-axis Helicon wave current drive in KSTAR. Simulation and test results of high power coaxial hybrid combiners are good agreement.

  7. Reliability and Energy Loss in Full-scale Wind Power Converter Considering Grid Codes and Wind Classes

    DEFF Research Database (Denmark)

    Zhou, Dao; Blaabjerg, Frede; Franke, Toke

    2014-01-01

    With the increasing penetration of the wind power, reliable operation and cost-effective wind energy production are of more and more importance. As one of the promising configurations, the cost on reliability and production losses of permanent-magnet synchronous generator based full-scale wind......, if the specific designed wind turbine system operates at different wind classes, it can be seen that higher wind class level results in lower lifetime of the power converter. In respect to the cost of the reactive power, either the OE or the UE reactive power increases the energy loss per year significantly...... power converter is studied considering the grid code with reactive power production as well as the annual wind profile. Regarding the reliability, it is found that either the Over-Excited (OE) or the Under-Excited (UE) reactive power injection threatens the lifespan under all wind classes. Meanwhile...

  8. AC Transport Current Loss in a Coated Superconductor in the Bean Model

    National Research Council Canada - National Science Library

    Carr, Jr, W. J

    2004-01-01

    A new and straightforward calculation is made of the loss in a very thin superconducting strip of rectangular cross section carrying ac transport current in zero applied magnetic field, with a similar...

  9. Fuzzy-TLBO optimal reactive power control variables planning for energy loss minimization

    International Nuclear Information System (INIS)

    Moghadam, Ahmad; Seifi, Ali Reza

    2014-01-01

    Highlights: • A new approach to the problem of optimal reactive power control variables planning is proposed. • The energy loss minimization problem has been formulated by modeling the load of system as a Load Duration Curve. • To solving the energy loss problem, the classic methods and the evolutionary methods are used. • A new proposed fuzzy teaching–learning based algorithm is applied to energy loss problem. • Simulations are done to show the effectiveness and superiority of the proposed algorithm compared with other methods. - Abstract: This paper offers a new approach to the problem of optimal reactive power control variables planning (ORPVCP). The basic idea is division of Load Duration Curve (LDC) into several time intervals with constant active power demand in each interval and then solving the energy loss minimization (ELM) problem to obtain an optimal initial set of control variables of the system so that is valid for all time intervals and can be used as an initial operating condition of the system. In this paper, the ELM problem has been solved by the linear programming (LP) and fuzzy linear programming (Fuzzy-LP) and evolutionary algorithms i.e. MHBMO and TLBO and the results are compared with the proposed Fuzzy-TLBO method. In the proposed method both objective function and constraints are evaluated by membership functions. The inequality constraints are embedded into the fitness function by the membership function of the fuzzy decision and the problem is modeled by fuzzy set theory. The proposed Fuzzy-TLBO method is performed on the IEEE 30 bus test system by considering two different LDC; and it is shown that using this method has further minimized objective function than original TLBO and other optimization techniques and confirms its potential to solve the ORPCVP problem with considering ELM as the objective function

  10. A Hybrid, Current-Source/Voltage-Source Power Inverter Circuit

    DEFF Research Database (Denmark)

    Trzynadlowski, Andrzej M.; Patriciu, Niculina; Blaabjerg, Frede

    2001-01-01

    A combination of a large current-source inverter and a small voltage-source inverter circuits is analyzed. The resultant hybrid inverter inherits certain operating advantages from both the constituent converters. In comparison with the popular voltage-source inverter, these advantages include...... reduced switching losses, improved quality of output current waveforms, and faster dynamic response to current control commands. Description of operating principles and characteristics of the hybrid inverter is illustrated with results of experimental investigation of a laboratory model....

  11. Hybrid switch for resonant power converters

    Science.gov (United States)

    Lai, Jih-Sheng; Yu, Wensong

    2014-09-09

    A hybrid switch comprising two semiconductor switches connected in parallel but having different voltage drop characteristics as a function of current facilitates attainment of zero voltage switching and reduces conduction losses to complement reduction of switching losses achieved through zero voltage switching in power converters such as high-current inverters.

  12. High stability, high current DC-power supplies

    International Nuclear Information System (INIS)

    Hosono, K.; Hatanaka, K.; Itahashi, T.

    1995-01-01

    Improvements of the power supplies and the control system of the AVF cyclotron which is used as an injector to the ring cyclotron and of the transport system to the ring cyclotron were done in order to get more high quality and more stable beam. The power supply of the main coil of the AVF cyclotron was exchanged to new one. The old DCCTs (zero-flux current transformers) used for the power supplies of the trim coils of the AVF cyclotron were changed to new DCCTs to get more stability. The potentiometers used for the reference voltages in the other power supplies of the AVF cyclotron and the transport system were changed to the temperature controlled DAC method for numerical-value settings. This paper presents the results of the improvements. (author)

  13. Microparticle-initiated losses in magnetically insulated transmission lines

    International Nuclear Information System (INIS)

    Gray, E.W.; Stinnett, R.W.

    1986-01-01

    The author's discuss the effects of high and hypervelocity microparticles in magnetically-insulated transmission lines (MITLs) and how they may be a possible source for ion production near the anode in early stages of the voltage pulse, and current carriers during and after the power pulse, resulting in power flow losses. Early losses in the voltage pulse, due to microparticles, are estimated to be approximately 0.3 mA/cm/sup 2/. Blistering of the electrode surface, thought to be due to H/sup -/ bombardment, was also observed and appears to be consistent with losses due to negative ions previously reported by one of the authors

  14. Transformerless photovoltaic inverters with leakage current and pulsating power elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Wang, H.

    2015-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Moreover, the proposed inverter can also eliminate the well-known double line frequency pulsating power....... The mechanism of leakage current suppression and the closed-loop control of pulsating power decoupling are discussed in the paper in details. A 500 W prototype was also built and tested in the laboratory, and both simulation and experimental results are finally presented to show the excellent performance...

  15. Conduction Losses and Common Mode EMI Analysis on Bridgeless Power Factor Correction

    DEFF Research Database (Denmark)

    Li, Qingnan; Andersen, Michael Andreas E.; Thomsen, Ole Cornelius

    2009-01-01

    In this paper, a review of Bridgeless Boost power factor correction (PFC) converters is presented at first. Performance comparison on conduction losses and common mode electromagnetic interference (EMI) are analyzed between conventional Boost PFC converter and members of Bridgeless PFC family...

  16. Active Power Flow Optimization of Industrial Power Supply with Regard to the Transmission Line Conductor Heating

    Directory of Open Access Journals (Sweden)

    Leyzgold D.Yu.

    2015-04-01

    Full Text Available This article studies the problem of the transmission line conductor heating effect on the active power flows optimization in the local segment of industrial power supply. The purpose is to determine the optimal generation rating of the distributed power sources, in which the power flow values will correspond to the minimum active power losses in the power supply. The timeliness is the need to define the most appropriate rated power values of distributed sources which will be connected to current industrial power supply. Basing on the model of active power flow optimization, authors formulate the description of the nonlinear transportation problem considering the active power losses depending on the transmission line conductor heating. Authors proposed a new approach to the heating model parameters definition based on allowable current loads and nominal parameters of conductors as part of the optimization problem. Analysis of study results showed that, despite the relatively small active power losses reduction to the tune 0,45% due to accounting of the conductors heating effect for the present configuration of power supply, there are significant fluctuations in the required generation rating in nodes of the network to 9,32% within seasonal changes in the outer air temperature. This fact should be taken into account when selecting the optimum power of distributed generation systems, as exemplified by an arbitrary network configuration.

  17. Why the Japanese Nuclear Power Plants are not trusted? Verification of current nuclear energy policy

    International Nuclear Information System (INIS)

    Yoshioka, Hitoshi

    2007-01-01

    Since the liberalization of electric power following the trend of structural reform and government's economic and financial rebuild had impacted the management of electric utilities in 1990, current nuclear power comes to be subject to government's leadership and support to promote nuclear energy. The Framework for Nuclear Energy Policy Japan of atomic energy commission in 2005 aims to (1) maintain the 30 to 40% or more share of nuclear energy in electricity generation up to 2030 and afterwards, (2) promote the nuclear fuel cycle and (3) commercialize the fast-breeder reactors. Nuclear Energy National Plan of ministry of economy, trade and industry in 2006 makes reference to construction of FBR demonstration reactor by 2025, development of Japanese next-generation LWR and also construction of second reprocessing plant. Major stakeholders related with nuclear power generation such as politicians, government (the authorities concerned), electric utilities and local governments play respective important role in nuclear policy as 'a tetrahedral structure'. The Niigataken Chuets-oki earthquake reminded risk problems of nuclear power management and shook the nuclear tetrahedron structure, which might collapse with loss of public trust. (T. Tanaka)

  18. Proposed high voltage power supply for the ITER relevant lower hybrid current drive system

    International Nuclear Information System (INIS)

    Sharma, P.K.; Kazarian, F.; Garibaldi, P.; Gassman, T.; Artaud, J.F.; Bae, Y.S.; Belo, J.; Berger-By, G.; Bernard, J.M.; Cara, Ph.; Cardinali, A.; Castaldo, C.; Ceccuzzi, S.; Cesario, R.; Decker, J.; Delpech, L.; Ekedahl, A.; Garcia, J.; Goniche, M.; Guilhem, D.

    2011-01-01

    In the framework of the EFDA task HCD-08-03-01, the ITER lower hybrid current drive (LHCD) system design has been reviewed. The system aims to generate 24 MW of RF power at 5 GHz, of which 20 MW would be coupled to the plasmas. The present state of the art does not allow envisaging a unitary output of the klystrons exceeding 500 kW, so the project is based on 48 klystron units, leaving some margin when the transmission lines losses are taken into account. A high voltage power supply (HVPS), required to operate the klystrons, is proposed. A single HVPS would be used to feed and operate four klystrons in parallel configuration. Based on the above considerations, it is proposed to design and develop twelve HVPS, based on pulse step modulator (PSM) technology, each rated for 90 kV/90 A. This paper describes in details, the typical electrical requirements and the conceptual design of the proposed HVPS for the ITER LHCD system.

  19. Nuclear power for sustainable development. Current status and future prospects

    International Nuclear Information System (INIS)

    Adamantiades, A.; Kessides, I.

    2009-01-01

    Interest in nuclear power has been revived as a result of volatile fossil fuel prices, concerns about the security of energy supplies, and global climate change. This paper describes the current status and future plans for expansion of nuclear power, the advances in nuclear reactor technology, and their impacts on the associated risks and performance of nuclear power. Advanced nuclear reactors have been designed to be simpler and safer, and to have lower costs than currently operating reactors. By addressing many of the public health and safety risks that plagued the industry since the accidents at Three Mile Island and Chernobyl, these reactors may help break the current deadlock over nuclear power. In that case, nuclear power could make a significant contribution towards reducing greenhouse gas emissions. However, significant issues persist, fueling reservations among the public and many decision makers. Nuclear safety, disposal of radioactive wastes, and proliferation of nuclear explosives need to be addressed in an effective and credible way if the necessary public support is to be obtained. (author)

  20. Consumer loss in Czech photovoltaic power plants in 2010–2011

    International Nuclear Information System (INIS)

    Průša, Jan; Klimešova, Andrea; Janda, Karel

    2013-01-01

    This paper provides a financial survey of a small sample of Czech photovoltaic (PV) plants. To evaluate the extent of market losses, we calculate the shadow market price of solar electricity. From the profit and loss accounts of the PV plants and the shadow market price we estimate the total economic loss generated by PV electricity sector in the Czech Republic. The presented microeconomic approach has two main advantages: firstly, we work with real observed data, which offsets the drawback of a limited sample. Secondly, the profit accounting calculation enables sensitivity analysis with respect to key variables of the plants. We show that money invested in PV plants would generate an annual loss of 8%. Given the estimated solar assets of CZK 165.6 billion (EUR 6.6 billion) as of December 2011, this translates in at least CZK 12.6 billion lost in the Czech solar sector in 2012. About 43% of this loss is due to high technology costs and corresponds to pure dead weight loss, while the remaining 57% constitute the redistributive profit component of subsidies. Finally, we calculate that unless electricity prices increase or technology costs decrease approximately sevenfold, PV plants will remain loss making. - Highlights: • We calculate economic losses generated by Czech photovoltaic power plants. • Without subsidies estimated loss is CZK 12.6 billion in 2012 (8% of invested assets). • 43% is the dead weight loss due to high technology costs. • 57% is the profit redistributed out of subsidies as interest payments to banks. • Only a 7-fold change in parameters of the model would make PV plants profitable

  1. Rational Design of Spur Gears Directed to Increase Efficiency and Decrease Loss by Friction

    OpenAIRE

    Gonzalo González Rey; Alejandra García Toll; María Eugenia García Domínguez

    2010-01-01

    External parallel-axis cylindrical gears are considered as very efficient means for transmitting mechanical power, but for requirements of maximum efficiency in the current machines and equipments a precision in the procedures of calculation of power losses is necessary. In this sense, the Technical Report ISO / TR 14179-1:2001 offers formulas with empirical and theoretical bases to evaluate the gear efficiency considering gear mesh losses, windage and churning losses, and losses by bearings ...

  2. [Current aspects of harmonization of classification of occupational hearing loss].

    Science.gov (United States)

    Pankova, V B; Sinëva, E L; Tavartkiladze, G A; Fedina, I N; Preobrazhenskaia, E A; Mukhamedova, G R

    2013-01-01

    The objective of the present work was to develop unified criteria for the evaluation of the severity of noise-induced hearing loss. Current approaches to taking expert decisions based on the results of medical examination of the patients with impaired hearing are substantially different due to the considerable difference between the criteria for the estimation of hearing envisaged by the international classification, occupational pathology classification, and the national system of medico-social expertise. We undertook an attempt to correct and harmonize the existing criteria for the estimation of severity of occupational hearing loss based on the integration of all the three classification in order to "reduce them to a common denominator" and thereby to ensure the basis for the unified diagnostic and expert decisions for the cases of hearing impairment of any etiology. The project proposed in this paper makes it possible to use unified criteria for the assessment of the degree of hearing loss caused by occupational noises for diagnostic purposes and expertise compatible with the internationally accepted approaches.

  3. Alpha particle loss in the TFTR DT experiments

    International Nuclear Information System (INIS)

    Zweben, S.J.; Darrow, D.S.; Herrmann, H.W.

    1995-01-01

    Alpha particle loss was measured during the TFTR DT experiments using a scintillator detector located at the vessel bottom in the ion grad-B drift direction. The DT alpha particle loss to this detector was consistent with the calculated first-orbit loss over the whole range of plasma current I=0.6-2.7 MA. In particular, the alpha particle loss rate per DT neutron did not increase significantly with fusion power up to 10.7 MW, indicating the absence of any new ''collective'' alpha particle loss processes in these experiments

  4. Consideration of neutral beam prompt loss in the design of a tokamak helicon antenna

    International Nuclear Information System (INIS)

    Pace, D.C.; Van Zeeland, M.A.; Fishler, B.; Murphy, C.

    2016-01-01

    Highlights: • Neutral beam prompt losses place appreciable power on an in-vessel tokamak antenna. • Simulations predict prompt loss power and inform protective tile design. • Experiments confirm the validity of the prompt loss simulations. - Abstract: Neutral beam prompt losses (injected neutrals that ionize such that their first poloidal transit intersects with the wall) can put appreciable power on the outer wall of tokamaks, and this power may damage the wall or other internal components. These prompt losses are simulated including a protruding helicon antenna installation in the DIII-D tokamak and it is determined that 160 kW of power will impact the antenna during the injection of a particular neutral beam. Protective graphite tiles are designed in response to this modeling and the wall shape of the installed antenna is precisely measured to improve the accuracy of these calculations. Initial experiments confirm that the antenna component temperature increases according to the amount of neutral beam energy injected into the plasma. In this case, only injection of beams that are aimed counter to the plasma current produce an appreciable power load on the outer wall, suggesting that the effect is of little concern for tokamaks featuring only co-current neutral beam injection. Incorporating neutral beam prompt loss considerations into the design of this in-vessel component serves to ensure that adequate protection or cooling is provided.

  5. Consideration of neutral beam prompt loss in the design of a tokamak helicon antenna

    Energy Technology Data Exchange (ETDEWEB)

    Pace, D.C., E-mail: pacedc@fusion.gat.com; Van Zeeland, M.A.; Fishler, B.; Murphy, C.

    2016-11-15

    Highlights: • Neutral beam prompt losses place appreciable power on an in-vessel tokamak antenna. • Simulations predict prompt loss power and inform protective tile design. • Experiments confirm the validity of the prompt loss simulations. - Abstract: Neutral beam prompt losses (injected neutrals that ionize such that their first poloidal transit intersects with the wall) can put appreciable power on the outer wall of tokamaks, and this power may damage the wall or other internal components. These prompt losses are simulated including a protruding helicon antenna installation in the DIII-D tokamak and it is determined that 160 kW of power will impact the antenna during the injection of a particular neutral beam. Protective graphite tiles are designed in response to this modeling and the wall shape of the installed antenna is precisely measured to improve the accuracy of these calculations. Initial experiments confirm that the antenna component temperature increases according to the amount of neutral beam energy injected into the plasma. In this case, only injection of beams that are aimed counter to the plasma current produce an appreciable power load on the outer wall, suggesting that the effect is of little concern for tokamaks featuring only co-current neutral beam injection. Incorporating neutral beam prompt loss considerations into the design of this in-vessel component serves to ensure that adequate protection or cooling is provided.

  6. Analysis of Loss-of-Offsite-Power Events 1997-2015

    Energy Technology Data Exchange (ETDEWEB)

    Johnson, Nancy Ellen [Idaho National Lab. (INL), Idaho Falls, ID (United States); Schroeder, John Alton [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-07-01

    Loss of offsite power (LOOP) can have a major negative impact on a power plant’s ability to achieve and maintain safe shutdown conditions. LOOP event frequencies and times required for subsequent restoration of offsite power are important inputs to plant probabilistic risk assessments. This report presents a statistical and engineering analysis of LOOP frequencies and durations at U.S. commercial nuclear power plants. The data used in this study are based on the operating experience during calendar years 1997 through 2015. LOOP events during critical operation that do not result in a reactor trip, are not included. Frequencies and durations were determined for four event categories: plant-centered, switchyard-centered, grid-related, and weather-related. Emergency diesel generator reliability is also considered (failure to start, failure to load and run, and failure to run more than 1 hour). There is an adverse trend in LOOP durations. The previously reported adverse trend in LOOP frequency was not statistically significant for 2006-2015. Grid-related LOOPs happen predominantly in the summer. Switchyard-centered LOOPs happen predominantly in winter and spring. Plant-centered and weather-related LOOPs do not show statistically significant seasonality. The engineering analysis of LOOP data shows that human errors have been much less frequent since 1997 than in the 1986 -1996 time period.

  7. Active current control in wind power plants during grid faults

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Phillip C.; Rodriguez, Pedro

    2010-01-01

    Modern wind power plants are required and designed to ride through faults in electrical networks, subject to fault clearing. Wind turbine fault current contribution is required from most countries with a high amount of wind power penetration. In order to comply with such grid code requirements......, wind turbines usually have solutions that enable the turbines to control the generation of reactive power during faults. This paper addresses the importance of using an optimal injection of active current during faults in order to fulfil these grid codes. This is of relevant importance for severe...... faults, causing low voltages at the point of common coupling. As a consequence, a new wind turbine current controller for operation during faults is proposed. It is shown that to achieve the maximum transfer of reactive current at the point of common coupling, a strategy for optimal setting of the active...

  8. Data on loss of off-site electric power simulation tests of the high temperature engineering test reactor

    International Nuclear Information System (INIS)

    Takeda, Takeshi; Nakagawa, Shigeaki; Fujimoto, Nozomu; Tachibana, Yukio; Iyoku, Tatsuo

    2002-07-01

    The high temperature engineering test reactor (HTTR), the first high temperature gas-cooled reactor (HTGR) in Japan, achieved the first full power of 30 MW on December 7 in 2001. In the rise-to-power test of the HTTR, simulation tests on loss of off-site electric power from 15 and 30 MW operations were carried out by manual shutdown of off-site electric power. Because helium circulators and water pumps coasted down immediately after the loss of off-site electric power, flow rates of helium and water decreased to the scram points. To shut down the reactor safely, the subcriticality should be kept by the insertion of control rods and the auxiliary cooling system should cool the core continuously avoiding excessive cold shock to core graphite components. About 50 s later from the loss of off-site electric power, the auxiliary cooling system started up by supplying electricity from emergency power feeders. Temperature of hot plenum block among core graphite structures decreased continuously after the startup of the auxiliary cooling system. This report describes sequences of dynamic components and transient behaviors of the reactor and its cooling system during the simulation tests from 15 and 30 MW operations. (author)

  9. AC losses in a type II superconductor strip with inhomogeneous critical current distribution

    International Nuclear Information System (INIS)

    Tsukamoto, Osami

    2005-01-01

    Analytical formulae derived by Brandt and Indenbom (1993 Phys. Rev. B 48 12893-906) and Norris (1970 J. Phys. D: Appl. Phys. 3 489-507) are often used to calculate the magnetization and AC transport current losses in HTS strip conductors, respectively. In these formulae, homogeneous distribution of critical sheet current density σ c in the strip is assumed. However, it is considered that σ c distributions are inhomogeneous in actual HTS strips and that the inhomogeneous σ c distributions cause deviations of the measured AC loss data of actual HTS strips from those formulae. A semi-analytical method to calculate AC transport current and magnetization losses is derived for a type II superconductor strip with inhomogeneous distribution of σ c in the direction of the strip width. The method is derived modifying the analysis of Brandt et al. The validity of the semi-analytical method is shown by comparing the results calculated by this method with those calculated by the Norris and Brandt formulae and by a different method of our previous work and also with experimental data. Moreover, it is shown that the deviation of the measured data from the Norris and Brandt models can be estimated by assuming proper σ c distributions

  10. Transient analysis for alternating over-current characteristics of HTSC power transmission cable

    Science.gov (United States)

    Lim, S. H.; Hwang, S. D.

    2006-10-01

    In this paper, the transient analysis for the alternating over-current distribution in case that the over-current was applied for a high-TC superconducting (HTSC) power transmission cable was performed. The transient analysis for the alternating over-current characteristics of HTSC power transmission cable with multi-layer is required to estimate the redistribution of the over-current between its conducting layers and to protect the cable system from the over-current in case that the quench in one or two layers of the HTSC power cable happens. For its transient analysis, the resistance generation of the conducting layers for the alternating over-current was reflected on its equivalent circuit, based on the resistance equation obtained by applying discrete Fourier transform (DFT) for the voltage and the current waveforms of the HTSC tape, which comprises each layer of the HTSC power transmission cable. It was confirmed through the numerical analysis on its equivalent circuit that after the current redistribution from the outermost layer into the inner layers first happened, the fast current redistribution between the inner layers developed as the amplitude of the alternating over-current increased.

  11. Power loss of an oscillating electric dipole in a quantum plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ghaderipoor, L. [Department of Physics, Faculty of Science, University of Qom, 3716146611 (Iran, Islamic Republic of); Mehramiz, A. [Department of Physics, Faculty of Science, Imam Khomeini Int' l University, Qazvin 34149-16818 (Iran, Islamic Republic of)

    2012-12-15

    A system of linearized quantum plasma equations (quantum hydrodynamic model) has been used for investigating the dispersion equation for electrostatic waves in the plasma. Furthermore, dispersion relations and their modifications due to quantum effects are used for calculating the power loss of an oscillating electric dipole. Finally, the results are compared in quantum and classical regimes.

  12. High current proton linear accelerators and nuclear power

    International Nuclear Information System (INIS)

    Tunnicliffe, P.R.; Chidley, B.G.; Fraser, J.S.

    1976-01-01

    This paper outlines a possible role that high-current proton linear accelerators might play as ''electrical breeders'' in the forthcoming nuclear-power economy. A high-power beam of intermediate energy protons delivered to an actinide-element target surrounded by a blanket of fertile material may produce fissile material at a competitive cost. Criteria for technical performance and, in a Canadian context, for costs are given and the major problem areas outlined not only for the accelerator and its associated rf power source but also for the target assembly. (author)

  13. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  14. Impact of Negative Sequence Current Injection by Wind Power Plants

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Göksu, Ömer; Teodorescu, Remus

    2013-01-01

    This paper presents an analysis of the impact from negative sequence current injection by wind power plants in power systems under steady-state and short-term unbalanced conditions, including faults. The separate positive and negative sequence current control capability of the grid-side converters...... of full scale converter type wind turbines may be utilized to alter voltage imbalance at the point of connection and further into the grid, in turn changing the resultant negative sequence current flow in the grid. The effects of such control actions have been analyzed and discussed through theoretical...

  15. Tidal power harnessing energy from water currents

    CERN Document Server

    Lyatkher, Victor

    2014-01-01

    As the global supply of conventional energy sources, such as fossil fuels, dwindles and becomes more and more expensive, unconventional and renewable sources of energy, such as power generation from water sources, is becoming more and more important.  Hydropower has been around for decades, but this book suggests new methods that are more cost-effective and less intrusive to the environment for creating power sources from rivers, the tides, and other sources of water.   The energy available from water currents is potentially much greater than society's needs.  Presenting a detailed discussi

  16. Electrical-Loss Analysis of Power-Split Hybrid Electric Vehicles

    Directory of Open Access Journals (Sweden)

    Andrea Bonfiglio

    2017-12-01

    Full Text Available The growing development of hybrid electric vehicles (HEVs has seen the spread of architectures with transmission based on planetary gear train, realized thanks to two electric machines. This architecture, by continuously regulating the transmission ratio, allows the internal combustion engine (ICE to work in optimal conditions. On the one hand, the average ICE efficiency is increased thanks to better loading situations, while, on the other hand, electrical losses are introduced due to the power circulation between the two electrical machines mentioned above. The aim of this study is then to accurately evaluate electrical losses and the average ICE efficiency in various operating conditions and over different road missions. The models used in this study are presented for both the Continuously Variable Transmission (CVT architecture and the Discontinuously Variable Transmission (DVT architecture. In addition, efficiency maps of the main components are shown. Finally, the simulation results are presented to point out strengths and weaknesses of the CVT architecture.

  17. Topography, power, and current source density of θ oscillations during reward processing as markers for alcohol dependence.

    Science.gov (United States)

    Kamarajan, Chella; Rangaswamy, Madhavi; Manz, Niklas; Chorlian, David B; Pandey, Ashwini K; Roopesh, Bangalore N; Porjesz, Bernice

    2012-05-01

    Recent studies have linked alcoholism with a dysfunctional neural reward system. Although several electrophysiological studies have explored reward processing in healthy individuals, such studies in alcohol-dependent individuals are quite rare. The present study examines theta oscillations during reward processing in abstinent alcoholics. The electroencephalogram (EEG) was recorded in 38 abstinent alcoholics and 38 healthy controls as they performed a single outcome gambling task, which involved outcomes of either loss or gain of an amount (10 or 50¢) that was bet. Event-related theta band (3.0-7.0 Hz) power following each outcome stimulus was computed using the S-transform method. Theta power at the time window of the outcome-related negativity (ORN) and positivity (ORP) (200-500 ms) was compared across groups and outcome conditions. Additionally, behavioral data of impulsivity and task performance were analyzed. The alcoholic group showed significantly decreased theta power during reward processing compared to controls. Current source density (CSD) maps of alcoholics revealed weaker and diffuse source activity for all conditions and weaker bilateral prefrontal sources during the Loss 50 condition when compared with controls who manifested stronger and focused midline sources. Furthermore, alcoholics exhibited increased impulsivity and risk-taking on the behavioral measures. A strong association between reduced anterior theta power and impulsive task-performance was observed. It is suggested that decreased power and weaker and diffuse CSD in alcoholics may be due to dysfunctional neural reward circuitry. The relationship among alcoholism, theta oscillations, reward processing, and impulsivity could offer clues to understand brain circuitries that mediate reward processing and inhibitory control. Copyright © 2011 Wiley-Liss, Inc.

  18. DC Link Current Estimation in Wind-Double Feed Induction Generator Power Conditioning System

    Directory of Open Access Journals (Sweden)

    MARIAN GAICEANU

    2010-12-01

    Full Text Available In this paper the implementation of the DC link current estimator in power conditioning system of the variable speed wind turbine is shown. The wind turbine is connected to double feed induction generator (DFIG. The variable electrical energy parameters delivered by DFIG are fitted with the electrical grid parameters through back-to-back power converter. The bidirectional AC-AC power converter covers a wide speed range from subsynchronous to supersynchronous speeds. The modern control of back-to-back power converter involves power balance concept, therefore its load power should be known in any instant. By using the power balance control, the DC link voltage variation at the load changes can be reduced. In this paper the load power is estimated from the dc link, indirectly, through a second order DC link current estimator. The load current estimator is based on the DC link voltage and on the dc link input current of the rotor side converter. This method presents certain advantages instead of using measured method, which requires a low pass filter: no time delay, the feedforward current component has no ripple, no additional hardware, and more fast control response. Through the numerical simulation the performances of the proposed DC link output current estimator scheme are demonstrated.

  19. Fast determination of the current loss mechanisms in textured crystalline Si-based solar cells

    Science.gov (United States)

    Nakane, Akihiro; Fujimoto, Shohei; Fujiwara, Hiroyuki

    2017-11-01

    A quite general device analysis method that allows the direct evaluation of optical and recombination losses in crystalline silicon (c-Si)-based solar cells has been developed. By applying this technique, the current loss mechanisms of the state-of-the-art solar cells with ˜20% efficiencies have been revealed. In the established method, the optical and electrical losses are characterized from the analysis of an experimental external quantum efficiency (EQE) spectrum with very low computational cost. In particular, we have performed the EQE analyses of textured c-Si solar cells by employing the experimental reflectance spectra obtained directly from the actual devices while using flat optical models without any fitting parameters. We find that the developed method provides almost perfect fitting to EQE spectra reported for various textured c-Si solar cells, including c-Si heterojunction solar cells, a dopant-free c-Si solar cell with a MoOx layer, and an n-type passivated emitter with rear locally diffused solar cell. The modeling of the recombination loss further allows the extraction of the minority carrier diffusion length and surface recombination velocity from the EQE analysis. Based on the EQE analysis results, the current loss mechanisms in different types of c-Si solar cells are discussed.

  20. Power Quality Improvement in a Cascaded Multilevel Inverter Interfaced Grid Connected System Using a Modified Inductive–Capacitive–Inductive Filter with Reduced Power Loss and Improved Harmonic Attenuation

    Directory of Open Access Journals (Sweden)

    Meenakshi Jayaraman

    2017-11-01

    Full Text Available Recently, multilevel inverters are more researched due to the advantages they offer over conventional voltage source inverters in grid connected applications. Passive filters are connected at the output of these inverters to produce sinusoidal waveforms with reduced harmonics and to satisfy grid interconnection standard requirements. This work proposes a new passive filter topology for a pulse width modulated five-level cascaded inverter interfaced grid connected system. The proposed passive filter inserts an additional resistance-capacitance branch in parallel to the filter capacitor of the traditional inductive–capacitive–inductive filter in addition to a resistance in series with it to reduce damping power loss. It can attenuate the switching frequency harmonic current components much better than the traditional filter while maintaining the same overall inductance, reduced capacitance and resistance values. The basic parameter design procedure and an approach to discover the parameters of the proposed filter is introduced. Further, a novel methodology using Particle Swarm Optimization (PSO is recommended to guarantee minimum damping loss while ensuring reduced peak during resonance. In addition, PSO algorithm is newly employed in this work to maximize harmonic attenuation in and around the switching frequency on the premise of allowable values of filter inductance and capacitance. A comparative discussion considering traditional passive filters and the proposed filter is presented and evaluated through experiments conducted on a 110 V, 1 kW five-level grid connected inverter. The modulation algorithm for the multilevel inverter is implemented using a SPARTAN 6-XC6SLX25 Field Programmable Gate Array (FPGA processor. The analysis shows that the proposed filter not only provides decreased damping power loss but also is capable of providing considerable harmonic ripple reduction in the high frequency band, improved output waveforms and lesser

  1. Tracing and Prediction of Losses for Deregulated Operation of Power Systems

    DEFF Research Database (Denmark)

    Nallagownden, Perumal; Mukerjee, Ravindra Nath; Masri, Syafrudin

    2011-01-01

    To facilitate both generation and retailing to have an open access to the transmission grid for trading electricity, a real time procedure is proposed. The line flows for an operation are assumed to be available from PMU and WAM validated state estimation. Power tracing determines different...... at the retail end and its associated line losses, for an oncoming operating scenario....

  2. HOM power in FCC-ee cavities

    CERN Document Server

    Karpov, Ivan; Chapochnikova, Elena

    2018-01-01

    This Note summarizes the results of the power loss calculations for FCC-ee machines with 400.79 MHz cavity options. The requirements for the single-cell cavity design and for the operation with beam are obtained from the results for the high-current FCC-ee machine (Z). For other machines the power loss is sufficiently low and can be absorbed and extracted by foreseen HOM couplers.

  3. Measurement based analysis of active and reactive power losses in a distribution network with wind farms and CHPs

    DEFF Research Database (Denmark)

    Lund, Torsten

    2007-01-01

    The paper presents an investigation of the active and reactive power losses in a distribution network with wind turbines and combined heat and power plants. The investigation is based on 15 min average power measurements and load flow calculations in the power system simulation tool PowerFactory...

  4. THE EVALUATION OF THE EFFECT OF REACTIVE POWER COMPENSATION IN ELECTRIC POWER LOSSES IN ELECTRIC NETWORK OF RAILWAY JUNCTION

    OpenAIRE

    O. I. Bondar; I. L. Bondar

    2009-01-01

    In this work the generalized mathematical model of an electrical network of the electrified railway junction is proposed. An estimation of influence of static var compensators installation on electric power losses in a network is executed on the basis of given model.

  5. Eddy Current Loss Modeling for Design of PM Generators for Wind Turbines

    NARCIS (Netherlands)

    Jassal, A.

    2014-01-01

    This thesis deals with analysis, calculation and validation of eddy current loss models for Permanent Magnet (PM) direct drive generators for wind turbines. The modelling approach is a mixed use of analytical and Finite Element (FE) methods. The models are validated experimentally and design

  6. Power system reconfiguration in a radial distribution network for reducing losses and to improve voltage profile using modified plant growth simulation algorithm with Distributed Generation (DG

    Directory of Open Access Journals (Sweden)

    R. Rajaram

    2015-11-01

    Full Text Available Network reconfiguration which is constrained non linear optimization problem has been solved for loss minimization, load balancing, etc. for last two decades using various heuristic search evolutionary algorithms like binary particle swarm optimization, neuro-fuzzy techniques, etc. The contribution of this paper lies in considering distributed generation which are smaller power sources like solar photovoltaic cells or wind turbines connected in the customer roof top. This new connection in the radial network has made unidirectional current flow to become bidirectional there by increasing the efficiency but sometimes reducing stability of the system. Modified plant growth simulation algorithm has been applied here successfully to minimize real power loss because it does not require barrier factors or cross over rates because the objectives and constraints are dealt separately. The main advantage of this algorithm is continuous guiding search along with changing objective function because power from distributed generation is continuously varying so this can be applied for real time applications with required modifications. This algorithm here is tested for a standard 33 bus radial distribution system for loss minimization and test results here shows that this algorithm is efficient and suitable for real time applications.

  7. Ion energy loss at maximum stopping power in a laser-generated plasma

    International Nuclear Information System (INIS)

    Cayzac, W.

    2013-01-01

    In the frame of this thesis, a new experimental setup for the measurement of the energy loss of carbon ions at maximum stopping power in a hot laser-generated plasma has been developed and successfully tested. In this parameter range where the projectile velocity is of the same order of magnitude as the thermal velocity of the plasma free electrons, large uncertainties of up to 50% are present in the stopping-power description. To date, no experimental data are available to perform a theory benchmarking. Testing the different stopping theories is yet essential for inertial confinement fusion and in particular for the understanding of the alpha-particle heating of the thermonuclear fuel. Here, for the first time, precise measurements were carried out in a reproducible and entirely characterized beam-plasma configuration. It involved a nearly fully-stripped ion beam probing a homogeneous fully-ionized plasma. This plasma was generated by irradiating a thin carbon foil with two high-energy laser beams and features a maximum electron temperature of 200 eV. The plasma conditions were simulated with a two-dimensional radiative hydrodynamic code, while the ion-beam charge-state distribution was predicted by means of a Monte-Carlo code describing the charge-exchange processes of projectile ions in plasma. To probe at maximum stopping power, high-frequency pulsed ion bunches were decelerated to an energy of 0.5 MeV per nucleon. The ion energy loss was determined by a time-of-flight measurement using a specifically developed chemical-vapor-deposition diamond detector that was screened against any plasma radiation. A first experimental campaign was carried out using this newly developed platform, in which a precision better than 200 keV on the energy loss was reached. This allowed, via the knowledge of the plasma and of the beam parameters, to reliably test several stopping theories, either based on perturbation theory or on a nonlinear T-Matrix formalism. A preliminary

  8. Female pattern hair loss: Current treatment concepts

    Directory of Open Access Journals (Sweden)

    Quan Q Dinh

    2007-07-01

    Full Text Available Quan Q Dinh, Rodney SinclairDepartment of Dermatology, St Vincent’s Hospital, Fitzroy, Victoria, AustraliaAbstract: Fewer than 45% of women go through life with a full head of hair. Female pattern hair loss is the commonest cause of hair loss in women and prevalence increases with advancing age. Affected women may experience psychological distress and impaired social functioning. In most cases the diagnosis can be made clinically and the condition treated medically. While many women using oral antiandrogens and topical minoxidil will regrow some hair, early diagnosis and initiation of treatment is desirable as these treatments are more effective at arresting progression of hair loss than stimulating regrowth. Adjunctive nonpharmacological treatment modalities such as counseling, cosmetic camouflage and hair transplantation are important measures for some patients. The histology of female pattern hair loss is identical to that of male androgenetic alopecia. While the clinical pattern of the hair loss differs between men, the response to oral antiandrogens suggests that female pattern hair loss is an androgen dependant condition, at least in the majority of cases. Female pattern hair loss is a chronic progressive condition. All treatments need to be continued to maintain the effect. An initial therapeutic response often takes 12 or even 24 months. Given this delay, monitoring for treatment effect through clinical photography or standardized clinical severity scales is helpful.Keywords: female pattern hair loss, androgenetic alopecia

  9. Limitations and Constraints of Eddy-Current Loss Models for Interior Permanent-Magnet Motors with Fractional-Slot Concentrated Windings

    Directory of Open Access Journals (Sweden)

    Hui Zhang

    2017-03-01

    Full Text Available This paper analyzes and compares models for predicting average magnet losses in interior permanent-magnet motors with fractional-slot concentrated windings due to harmonics in the armature reaction (assuming sinusoidal phase currents. Particularly, loss models adopting different formulations and solutions to the Helmholtz equation to solve for the eddy currents are compared to a simpler model relying on an assumed eddy-current distribution. Boundaries in terms of magnet dimensions and angular frequency are identified (numerically and using an identified approximate analytical expression to aid the machine designer whether the more simple loss model is applicable or not. The assumption of a uniform flux-density variation (used in the loss models is also investigated for the case of V-shaped and straight interior permanent magnets. Finally, predicted volumetric loss densities are exemplified for combinations of slot and pole numbers common in automotive applications.

  10. Iaverage current mode (ACM) control for switching power converters

    OpenAIRE

    2014-01-01

    Providing a fast current sensor direct feedback path to a modulator for controlling switching of a switched power converter in addition to an integrating feedback path which monitors average current for control of a modulator provides fast dynamic response consistent with system stability and average current mode control. Feedback of output voltage for voltage regulation can be combined with current information in the integrating feedback path to limit bandwidth of the voltage feedback signal.

  11. NMOS-Based Integrated Modular Bypass for Use in Solar Systems (NIMBUS: Intelligent Bypass for Reducing Partial Shading Power Loss in Solar Panel Applications

    Directory of Open Access Journals (Sweden)

    Pieter Bauwens

    2016-06-01

    Full Text Available NMOS-based Integrated Modular Bypass for Use in Solar systems (NIMBUS is designed as a replacement for the traditional bypass diode, used in common solar panels. Because of the series connection between the individual solar cells, the power output of a photovoltaic (PV panel will drop disproportionally under partial shading. Currently, this is solved by dividing the PV panel into substrings, each with a diode bypass placed in parallel. This allows an alternative current path. However, the diodes still have a significant voltage drop (about 350 mV, and due to the fairly large currents in a panel, the diodes are dissipating power that we would rather see at the output of the panel. The NIMBUS chip, being a low-voltage-drop switch, aims to replace these diodes and, thus, reduce that power loss. NIMBUS is a smart bypass: a completely stand-alone system that detects the failing of one or more cells and activates when necessary. It is designed for a 100-mV voltage drop under a 5-A load current. When two or more NIMBUS chips are placed in parallel, an internal synchronization circuit ensures proper operation to provide for larger load currents. This paper will elaborate on the operation, design and implementation of the NIMBUS chip, as well as on the first measurements.

  12. Windage Power Loss in Gas Foil Bearings and the Rotor-Stator Clearance of High Speed Generators Operating in High Pressure Environments

    Science.gov (United States)

    Bruckner, Robert J.

    2009-01-01

    Closed Brayton Cycle (CBC) and Closed Supercritical Cycle (CSC) engines are prime candidates to convert heat from a reactor into electric power for robotic space exploration and habitation. These engine concepts incorporate a permanent magnet starter/generator mounted on the engine shaft along with the requisite turbomachinery. Successful completion of the long-duration missions currently anticipated for these engines will require designs that adequately address all losses within the machine. The preliminary thermal management concept for these engine types is to use the cycle working fluid to provide the required cooling. In addition to providing cooling, the working fluid will also serve as the bearing lubricant. Additional requirements, due to the unique application of these microturbines, are zero contamination of the working fluid and entirely maintenance-free operation for many years. Losses in the gas foil bearings and within the rotor-stator gap of the generator become increasingly important as both rotational speed and mean operating pressure are increased. This paper presents the results of an experimental study, which obtained direct torque measurements on gas foil bearings and generator rotor-stator gaps. Test conditions for these measurements included rotational speeds up to 42,000 revolutions per minute, pressures up to 45 atmospheres, and test gases of nitrogen, helium, and carbon dioxide. These conditions provided a maximum test Taylor number of nearly one million. The results show an exponential rise in power loss as mean operating density is increased for both the gas foil bearing and generator windage. These typical "secondary" losses can become larger than the total system output power if conventional design paradigms are followed. A nondimensional analysis is presented to extend the experimental results into the CSC range for the generator windage.

  13. The measurement of power losses at high magnetic field densities or at small cross-section of test specimen using the averaging

    CERN Document Server

    Gorican, V; Hamler, A; Nakata, T

    2000-01-01

    It is difficult to achieve sufficient accuracy of power loss measurement at high magnetic field densities where the magnetic field strength gets more and more distorted, or in cases where the influence of noise increases (small specimen cross section). The influence of averaging on the accuracy of power loss measurement was studied on the cast amorphous magnetic material Metglas 2605-TCA. The results show that the accuracy of power loss measurements can be improved by using the averaging of data acquisition points.

  14. Enhanced magnetic domain relaxation frequency and low power losses in Zn{sup 2+} substituted manganese ferrites potential for high frequency applications

    Energy Technology Data Exchange (ETDEWEB)

    Praveena, K., E-mail: praveenaou@gmail.com [Department of Physics, National Taiwan Normal University, Taipei, 11677, Taiwan (China); Chen, Hsiao-Wen [Department of Physics, National Taiwan Normal University, Taipei, 11677, Taiwan (China); Liu, Hsiang-Lin, E-mail: hliu@ntnu.edu.tw [Department of Physics, National Taiwan Normal University, Taipei, 11677, Taiwan (China); Sadhana, K., E-mail: sadhana@osmania.ac.in [Department of Physics, Osmania University, Saifabad, Hyderabad, 500004 (India); Murthy, S.R. [Department of Physics, Osmania University, Hyderabad, 500007 (India)

    2016-12-15

    Nowadays electronic industries prerequisites magnetic materials, i.e., iron rich materials and their magnetic alloys. However, with the advent of high frequency applications, the standard techniques of reducing eddy current losses, using iron cores, were no longer efficient or cost effective. Current market trends of the switched mode power supplies industries required even low energy losses in power conversion with maintenance of adequate initial permeability. From the above point of view, in the present study we aimed at the production of Manganese–Zinc ferrites prepared via solution combustion method using mixture of fuels and achieved low loss, high saturation magnetization, high permeability, and high magnetic domain relaxation frequency. The as-synthesized Zn{sup 2+} substituted MnFe{sub 2}O{sub 4} were characterized by X-ray diffractometer (XRD) and transmission electron microscopy (TEM). The fractions of Mn{sup 2+}, Zn{sup 2+} and Fe{sup 2+} cations occupying tetrahedral sites along with Fe occupying octahedral sites within the unit cell of all ferrite samples were estimated by Raman scattering spectroscopy. The magnetic domain relaxation was investigated by inductance spectroscopy (IS) and the observed magnetic domain relaxation frequency (f{sub r}) was increased with the increase in grain size. The real and imaginary part of permeability (μ′ and μ″) increased with frequency and showed a maximum above 100 MHz. This can be explained on the basis of spin rotation and domain wall motion. The saturation magnetization (M{sub s}), remnant magnetization (M{sub r}) and magneton number (µ{sub B}) decreased gradually with increasing Zn{sup 2+} concentration. The decrease in the saturation magnetization was discussed with Yafet–Kittel (Y–K) model. The Zn{sup 2+} concentration increases the relative number of ferric ions on the A sites, reduces the A–B interactions. The frequency dependent total power losses decreased as the zinc concentration increased

  15. Development of Ground Coils with Low Eddy Current Loss by Applying the Compression Molding Method after the Coil Winding

    Science.gov (United States)

    Suzuki, Masao; Aiba, Masayuki; Takahashi, Noriyuki; Ota, Satoru; Okada, Shigenori

    In a magnetically levitated transportation (MAGLEV) system, a huge number of ground coils will be required because they must be laid for the whole line. Therefore, stable performance and reduced cost are essential requirements for the ground coil development. On the other hand, because the magnetic field changes when the superconducting magnet passes by, an eddy current will be generated in the conductor of the ground coil and will result in energy loss. The loss not only increases the magnetic resistance for the train running but also brings an increase in the ground coil temperature. Therefore, the reduction of the eddy current loss is extremely important. This study examined ground coils in which both the eddy current loss and temperature increase were small. Furthermore, quantitative comparison for the eddy current loss of various magnet wire samples was performed by bench test. On the basis of the comparison, a round twisted wire having low eddy current loss was selected as an effective ground coil material. In addition, the ground coils were manufactured on trial. A favorable outlook to improve the size accuracy of the winding coil and uneven thickness of molded resin was obtained without reducing the insulation strength between the coil layers by applying a compression molding after winding.

  16. Study of pulse stretching in high current power supplies using multipulse techniques

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1977-01-01

    Considerable interest exists at Fermilab to increase the pulse width of the Neutrino Focusing Horn to permit an increase in beam spill length from twenty (20) microseconds to one (1) millisecond. Two techniques to do this were examined: (1) a high current transformer, and (2) increased bank capacitance using the multi-power supply technique. The transformer is the most straightforward conceptually; it is, however, a complicated device requiring sizable changes to the existing horn power supply. This alternative is briefly reviewed. The second scheme involves pulsing a 20 kv 200 ka power supply to establish the required load current and then maintaining this current by the sequential pulsing of a number of low voltage high current power supplies. This alternative is discussed in detail with the results of tests performed on the Fermilab Focusing Horn System

  17. Development of a current-type PWM converter with high power factor. 1

    International Nuclear Information System (INIS)

    Miura, Yushi; Matsukawa, Makoto; Miyachi, Kengo; Kimura, Toyoaki

    1998-01-01

    A power supply system for superconducting poloidal field coils of a next generation tokamak-type fusion device can be operated on the relatively low voltage for the duration of discharge except the plasma initiation. In the case of the conventional phase-controlled thyristor converters are adopted in such a system, the input power factor would be low in average, and a reactive power fluctuation caused by the change of DC output voltage may produce serious effects on the commercial transmission line. From the above viewpoint, a current-type PWM (Pulse Width Modulation) converter, which can work with the power factor of unity for the input power, is regarded as one of the promising candidates of the converters for the power supplies of next generation fusion devices. Hence, a 100kW-class current-type PWM converter has been developed by using IGBT (Insulated Gate Bipolar Transistor) as switching devices. In this development, the basic performance has been preliminary investigated whether this converter is applicable to the power supply for the next generation fusion device. In addition, two different PWM control methods were examined whether these methods can realize a unit power factor and suppress the transient oscillation of converter input current at the same time in case that the reference of DC output current is changed rapidly. (author)

  18. Control strategy minimizing the converter-alternating current motor losses: application to electric traction; Strategies de commande minimisant les pertes d'un ensemble convertisseur - machine alternative: application a la traction electrique

    Energy Technology Data Exchange (ETDEWEB)

    Bastiani, Ph.

    2001-02-01

    Improving the efficiency of the converter-alternating current motor system is a major task in electric traction. Global energy optimisation implies a specific approach at system scale. To reach this goal, we have chosen an algebraic method using sub-system models. To start with, a synchronous machine Park model is developed to take account magnetic saturation and iron losses. Then, an averaged model of the voltage inverter is used in order to obtain a simplified model of the losses to be implemented in our optimisation method. This is how the global model is built including losses in the synchronous machine along with the losses of the power converter. Experimental results are there to validate our approach. This study proposes a method based on algebraic formulation of the general laws to control torque. Algorithms take into account magnetic circuits saturation and power losses in both the machine and its converter. Here again, experimental results validate the algorithm on several test benches. Achieved efficiency improvement is important compared to existing usual control strategies. The proposed method can be generalised to other machine-converter systems. As a matter of fact we have extended our study to the induction machine. As a complement ti this study we have looked at the effects natural limitations of voltages and currents in the torque-speed plane. Therefore algebraic formulation of the torque-speed plane and optimisation strategies are proposed including those constraints. (author)

  19. Firefly algorithm based solution to minimize the real power loss in a power system

    Directory of Open Access Journals (Sweden)

    P. Balachennaiah

    2018-03-01

    Full Text Available This paper proposes a method to minimize the real power loss (RPL of a power system transmission network using a new meta-heuristic algorithm known as firefly algorithm (FA by optimizing the control variables such as transformer taps, UPFC location and UPFC series injected voltage magnitude and phase angle. A software program is developed in MATLAB environment for FA to minimize the RPL by optimizing (i only the transformer tap values, (ii only UPFC location and its variables with optimized tap values and (iii UPFC location and its variables along with transformer tap setting values simultaneously. Interior point successive linear programming (IPSLP technique and real coded genetic algorithm (RCGA are considered here to compare the results and to show the efficiency and superiority of the proposed FA towards the optimization of RPL. Also in this paper, bacteria foraging algorithm (BFA is adopted to validate the results of the proposed algorithm.

  20. A Combined Experimental and Finite Element Analysis Method for the Estimation of Eddy-Current Loss in NdFeB Magnets

    Directory of Open Access Journals (Sweden)

    Radu Fratila

    2014-05-01

    Full Text Available NdFeB permanent magnets (PMs are widely used in high performance electrical machines, but their relatively high conductivity subjects them to eddy current losses that can lead to magnetization loss. The Finite Element (FE method is generally used to quantify the eddy current loss of PMs, but it remains quite difficult to validate the accuracy of the results with complex devices. In this paper, an experimental test device is used in order to extract the eddy current losses that are then compared with those of a 3D FE model.

  1. A combined experimental and finite element analysis method for the estimation of eddy-current loss in NdFeB magnets.

    Science.gov (United States)

    Fratila, Radu; Benabou, Abdelkader; Tounzi, Abdelmounaïm; Mipo, Jean-Claude

    2014-05-14

    NdFeB permanent magnets (PMs) are widely used in high performance electrical machines, but their relatively high conductivity subjects them to eddy current losses that can lead to magnetization loss. The Finite Element (FE) method is generally used to quantify the eddy current loss of PMs, but it remains quite difficult to validate the accuracy of the results with complex devices. In this paper, an experimental test device is used in order to extract the eddy current losses that are then compared with those of a 3D FE model.

  2. Separation Test Method for Investigation of Current Density Effects on Bond Wires of SiC Power MOSFET Modules

    DEFF Research Database (Denmark)

    Luo, Haoze; Iannuzzo, Francesco; Blaabjerg, Frede

    2017-01-01

    and average temperature during the test. By analyzing the output characteristics of the linear region of MOSFET, the constraint relations among the gate voltage, on-state voltage drop and junction temperature are revealed in this paper. The one-to-one correspondence between gate voltage and conduction power...... loss can be used to adjust the current density under fixed temperature swing and average temperature. The commercial Silicon Carbide (SiC) MOSFET modules are tested to experimentally verify the proposed method. Finally, the effectiveness of proposed test method is validated by the experimental results....

  3. CMOS circuits for piezoelectric energy harvesters efficient power extraction, interface modeling and loss analysis

    CERN Document Server

    Hehn, Thorsten

    2014-01-01

    This book deals with the challenge of exploiting ambient vibrational energy which can be used to power small and low-power electronic devices, e.g. wireless sensor nodes. Generally, particularly for low voltage amplitudes, low-loss rectification is required to achieve high conversion efficiency. In the special case of piezoelectric energy harvesting, pulsed charge extraction has the potential to extract more power compared to a single rectifier. For this purpose, a fully autonomous CMOS integrated interface circuit for piezoelectric generators which fulfills these requirements is presented.Due

  4. High-Bandwidth, High-Efficiency Envelope Tracking Power Supply for 40W RF Power Amplifier Using Paralleled Bandpass Current Sources

    DEFF Research Database (Denmark)

    Høyerby, Mikkel Christian Wendelboe; Andersen, Michael Andreas E.

    2005-01-01

    This paper presents a high-performance power conversion scheme for power supply applications that require very high output voltage slew rates (dV/dt). The concept is to parallel 2 switching bandpass current sources, each optimized for its passband frequency space and the expected load current....... The principle is demonstrated with a power supply, designed for supplying a 40 W linear RF power amplifier for efficient amplification of a 16-QAM modulated data stream...

  5. Possibilities and consequences of the Total Cumulative Exergy Loss method in improving the sustainability of power generation

    International Nuclear Information System (INIS)

    Stougie, Lydia; Kooi, Hedzer J. van der

    2016-01-01

    Highlights: • The TCExL method can be applied to all kinds of technological systems. • All exergy losses during the lifetime of a technological system are considered. • The results of the TCExL method are independent of time and weighting factors. • Applying the TCExL method can improve the sustainability of power generation. • The system with the lowest TCExL score is not always economically favourable. - Abstract: It is difficult to decide which power generation system is the most sustainable when environmental, economic and social sustainability aspects are taken into account. Problems with conventional environmental sustainability assessment methods are that no consensus exists about the applied models and weighting factors and that exergy losses are not considered. Economic sustainability assessment methods do not lead to results that are independent of time because they are influenced by market developments, while social sustainability assessment methods suffer from the availability and qualitative or semi-quantitative nature of data. Existing exergy analysis methods do not take into account all exergy losses and/or are extended with factors or equations that are not commonly accepted. The new Total Cumulative Exergy Loss (TCExL) method is based on fundamental thermodynamic equations and takes into account all exergy losses caused by a technological system during its life cycle, i.e. internal exergy losses, exergy losses caused by emission abatement and exergy losses related to land use. The development of the TCExL method is presented as well as the application of this method and environmental, economic and social sustainability assessment methods to two case studies: power generation in combination with LNG evaporation and Fossil versus renewable energy sources for power generation. According to the results of the assessments, large differences exist between the environmental sustainability assessment and TCExL methods in the sense that different

  6. Design of The High Efficiency Power Factor Correction Circuit for Power Supply

    Directory of Open Access Journals (Sweden)

    Atiye Hülya OBDAN

    2017-12-01

    Full Text Available Designing power factor correction circuits for switched power supplies has become important in recent years in terms of efficient use of energy. Power factor correction techniques play a significant role in high power density and energy efficiency. For these purposes, bridgeless PFC topologies and control strategies have been developed alongside basic boost PFC circuits. The power density can be increased using bridgeless structures by means of reducing losses in the circuit. This article examines bridgeless PFC structures and compares their performances in terms of losses and power factor. A semi-bridgeless PFC, which is widely used at high power levels, was analyzed and simulated. The designed circuit simulation using the current mode control method was performed in the PSIM program. A prototype of a 900 W semi-bridgeless PFC circuit was implemented and the results obtained from the circuit are presented

  7. AC over-current test results of YBCO conductor for YBCO power transformer with fault current limiting function

    International Nuclear Information System (INIS)

    Tomioka, A.; Otonari, T.; Ogata, T.; Iwakuma, M.; Okamoto, H.; Hayashi, H.; Iijima, Y.; Saito, T.; Gosho, Y.; Tanabe, K.; Izumi, T.; Shiohara, Y.

    2011-01-01

    The single-layer coils with a diameter of 250 mm and 12 turns were manufactured with YBCO tapes with a CuNi- or Cu-Tape. The AC over-current tests were carried out in subcooled liquid nitrogen at 66 K and 74 K to develop power transformers with current limiting function. The AC over-current was two to seven times larger than the I c of conductor and it was reduced to the same level of I c . The I c of model coils did not degrade. The test results showed the possibility of YBCO superconducting transformers with current limiting function. We are developing elemental technology for 66 kV/6.9 kV 20 MVA-class YBCO power transformer. The YBCO transformer is considered to have a possibility to stabilize the power system by improving function of fault current limiting. Current limiting behavior functions over critical current flows. There is a possibility that superconducting characteristic may be damaged due to increase in temperature of YBCO tapes. Therefore, we have taken a measure to combine YBCO tape with CuNi tape or Cu Tape. We manufactured model coils using these conductors and conducted the AC over-current tests. The test current was two to seven times larger than the I c of conductor and it was damped with time from its maximum value according to the generation of conductor resistance. We verified the effectiveness of current limiting characteristics. In these tests, the I c of model coil did not degrade. We consider this conductor to be able to withstand AC over-current with the function of current limiting.

  8. On the problem of internal optical loss and current leakage in laser heterostructures based on AlGaInAs/InP solid solutions

    International Nuclear Information System (INIS)

    Veselov, D. A.; Shashkin, I. S.; Bakhvalov, K. V.; Lyutetskiy, A. V.; Pikhtin, N. A.; Rastegaeva, M. G.; Slipchenko, S. O.; Bechvay, E. A.; Strelets, V. A.; Shamakhov, V. V.; Tarasov, I. S.

    2016-01-01

    Semiconductor lasers based on MOCVD-grown AlGaInAs/InP separate-confinement heterostructures are studied. It is shown that raising only the energy-gap width of AlGaInAs-waveguides without the introduction of additional barriers results in more pronounced current leakage into the cladding layers. It is found that the introduction of additional barrier layers at the waveguide–cladding-layer interface blocks current leakage into the cladding layers, but results in an increase in the internal optical loss with increasing pump current. It is experimentally demonstrated that the introduction of blocking layers makes it possible to obtain maximum values of the internal quantum efficiency of stimulated emission (92%) and continuouswave output optical power (3.2 W) in semiconductor lasers in the eye-safe wavelength range (1400–1600 nm).

  9. On the problem of internal optical loss and current leakage in laser heterostructures based on AlGaInAs/InP solid solutions

    Energy Technology Data Exchange (ETDEWEB)

    Veselov, D. A., E-mail: dmitriy90@list.ru; Shashkin, I. S.; Bakhvalov, K. V.; Lyutetskiy, A. V.; Pikhtin, N. A.; Rastegaeva, M. G.; Slipchenko, S. O.; Bechvay, E. A.; Strelets, V. A.; Shamakhov, V. V.; Tarasov, I. S. [Russian Academy of Sciences, Ioffe Physical–Technical Institute (Russian Federation)

    2016-09-15

    Semiconductor lasers based on MOCVD-grown AlGaInAs/InP separate-confinement heterostructures are studied. It is shown that raising only the energy-gap width of AlGaInAs-waveguides without the introduction of additional barriers results in more pronounced current leakage into the cladding layers. It is found that the introduction of additional barrier layers at the waveguide–cladding-layer interface blocks current leakage into the cladding layers, but results in an increase in the internal optical loss with increasing pump current. It is experimentally demonstrated that the introduction of blocking layers makes it possible to obtain maximum values of the internal quantum efficiency of stimulated emission (92%) and continuouswave output optical power (3.2 W) in semiconductor lasers in the eye-safe wavelength range (1400–1600 nm).

  10. Power sector reform in India: current issues and prospects

    International Nuclear Information System (INIS)

    Singh, Anoop

    2006-01-01

    Power sector reforms in India were initiated at a juncture when the sector was plagued with commercial losses and burgeoning subsidy burden. Investment in the sector was not able to keep pace with growing demand for electricity. This paper takes stock of pre-reform situation in Indian power sector and identifies key concerns that led to initiation of the process of reform. The paper discusses major policy and regulatory changes undertaken since the early 1990s. The paper also illustrates changes in the market structure as we move along the reform process. We also discuss some of the major provisions of the recently enacted Electricity Act 2003 that aims to replace the prevailing acts which govern the functioning of the power sector in the country. In this context, we discuss two issues arising out of it, namely open access and multi-year tariff that we think would have a significant bearing on the performance of the sector in the near future. The paper also evaluates the reform process in the light of some of the regulatory changes undertaken. Finally, the paper briefly discusses the issues involved in introduction of competition in the power sector primarily through development of a market for bulk power

  11. Method to predetermine current/power flow change in a dc grid

    DEFF Research Database (Denmark)

    2017-01-01

    occurs at one of the AC/DC converters; establishing a generalized droop feedback gain matrix G; controlling current/power flow within DC grid towards predefined setpoints, by use of control law. The invention presents an analytical approach to derive the generalized feedback gain allowing......The invention relates to a method for controlling current/power flow within a power transmission system, comprising two or more interconnected converter stations. The method comprises the steps of: providing a DC admittance matrix given from the DC grid; providing a current distribution matrix...... for a number of, such as for all possible AC/DC converter outages; providing a DC bus voltage vector for the DC grid; the DC bus voltage vector being a vector containing the values of the voltage change at the AC/DC converters, measured at the AC/DC converters, before, during and after a forced current change...

  12. Effect of capacitor loss on discharging characteristics of xenon flash lamp

    International Nuclear Information System (INIS)

    Zhang Chu; Lin Dejiang; Xu Chunmei; Shen Hongbin; Chen Xiaohan

    2012-01-01

    The effect of storage capacitor's loss on the discharging characteristics of the xenon flash lamp was studied, and the xenon flash lamp discharging circuit was analyzed and improved. The capacitor can be equivalent to a series of an ideal capacitor and loss resistance. The improved formula of the xenon lamp discharging characteristics was given when actual capacitance loss is not zero, and the xenon lamp discharging current and discharging power are calculated and analyzed in detail with the increase of the capacitor loss. The results show that the increase of loss will lead to the decrease of xenon lamp discharging current and peak power and the xenon lamp flash time, and influence laser pumping efficiency. The loss will also lead to the capacitor inverse charging in LC discharging circuit; this will influence normal working of the capacitor and decrease the lift of the xenon lamp. The actual energy storage capacitor charging and discharging experiments show that the increase of capacitor loss will lead to the decrease of xenon lamp light-emitting waveform peak, shortening of the flash time and increase of the electrode sputter, thus verity, the reasonableness of theoretical analysis. In addition, the experiments show that environmental factors have very significant impact on the increase of the storage capacitor loss. (authors)

  13. Social power and social class: conceptualization, consequences, and current challenges.

    Science.gov (United States)

    Rucker, Derek D; Galinsky, Adam D

    2017-12-01

    This article offers a primer on social power and social class with respect to their theoretical importance, conceptual distinction, and empirical relationship. We introduce and define the constructs of social power, social class, and one's psychological sense of power. We next explore the complex relationship between social power and social class. Because social class can produce a sense of power within an individual, studies on social power can inform theory and research on social class. We conclude with a discussion of the current challenges and future opportunities for the study of social power and social class. Copyright © 2017 Elsevier Ltd. All rights reserved.

  14. Estimation of steady-state and transcient power distributions for the RELAP analyses of the 1963 loss-of-flow and loss-of-pressure tests at BR2

    International Nuclear Information System (INIS)

    Dionne, B.; Tzanos, C.P.

    2011-01-01

    To support the safety analyses required for the conversion of the Belgian Reactor 2 (BR2) from highly-enriched uranium (HEU) to low-enriched uranium (LEU) fuel, the simulation of a number of loss-of-flow tests, with or without loss of pressure, has been undertaken. These tests were performed at BR2 in 1963 and used instrumented fuel assemblies (FAs) with thermocouples (TC) imbedded in the cladding as well as probes to measure the FAs power on the basis of their coolant temperature rise. The availability of experimental data for these tests offers an opportunity to better establish the credibility of the RELAP5-3D model and methodology used in the conversion analysis. In order to support the HEU to LEU conversion safety analyses of the BR2 reactor, RELAP simulations of a number of loss-of-flow/loss-of-pressure tests have been undertaken. Preliminary analyses showed that the conservative power distributions used historically in the BR2 RELAP model resulted in a significant overestimation of the peak cladding temperature during the transient. Therefore, it was concluded that better estimates of the steady-state and decay power distributions were needed to accurately predict the cladding temperatures measured during the tests and establish the credibility of the RELAP model and methodology. The new approach ('best estimate' methodology) uses the MCNP5, ORIGEN-2 and BERYL codes to obtain steady-state and decay power distributions for the BR2 core during the tests A/400/1, C/600/3 and F/400/1. This methodology can be easily extended to simulate any BR2 core configuration. Comparisons with measured peak cladding temperatures showed a much better agreement when power distributions obtained with the new methodology are used.

  15. Loss of cultural world heritage and currently inhabited places to sea-level rise

    International Nuclear Information System (INIS)

    Marzeion, Ben; Levermann, Anders

    2014-01-01

    The world population is concentrated near the coasts, as are a large number of Cultural World Heritage sites, defined by the UNESCO. Using spatially explicit sea-level estimates for the next 2000 years and high-resolution topography data, we compute which current cultural heritage sites will be affected by sea-level rise at different levels of sustained future warming. As indicators for the pressure on future cultural heritage we estimate the percentage of each country’s area loss, and the percentage of current population living in regions that will be permanently below sea level, for different temperature levels. If the current global mean temperature was sustained for the next two millennia, about 6% (40 sites) of the UNESCO sites will be affected, and 0.7% of global land area will be below mean sea level. These numbers increase to 19% (136 sites) and 1.1% for a warming of 3 K. At this warming level, 3–12 countries will experience a loss of more than half of their current land surface, 25–36 countries lose at least 10% of their territory, and 7% of the global population currently lives in regions that will be below local sea level. Given the millennial scale lifetime of carbon dioxide in the atmosphere, our results indicate that fundamental decisions with regard to mankind’s cultural heritage are required. (paper)

  16. Highly Reliable Transformerless Photovoltaic Inverters With Leakage Current and Pulsating Power Elimination

    DEFF Research Database (Denmark)

    Tang, Yi; Yao, Wenli; Loh, Poh Chiang

    2016-01-01

    This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV-to-ground parasi......This paper presents a transformerless inverter topology, which is capable of simultaneously solving leakage current and pulsating power issues in grid-connected photovoltaic (PV) systems. Without adding any additional components to the system, the leakage current caused by the PV......-to-ground parasitic capacitance can be bypassed by introducing a common-mode (CM) conducting path to the inverter. The resulting ground leakage current is therefore well controlled to be below the regulation limit. Furthermore, the proposed inverter can also eliminate the well-known double-line-frequency pulsating...... power that is inherent in single-phase PV systems. By properly injecting CM voltages to the output filter capacitors, the pulsating power can be decoupled from the dc-link. Therefore, it is possible to use long-lifetime film capacitors instead of electrolytic capacitors to improve the reliability...

  17. Efficient direct yaw moment control: tyre slip power loss minimisation for four-independent wheel drive vehicle

    Science.gov (United States)

    Kobayashi, Takao; Katsuyama, Etsuo; Sugiura, Hideki; Ono, Eiichi; Yamamoto, Masaki

    2018-05-01

    This paper proposes an efficient direct yaw moment control (DYC) capable of minimising tyre slip power loss on contact patches for a four-independent wheel drive vehicle. Simulations identified a significant power loss reduction with a direct yaw moment due to a change in steer characteristics during acceleration or deceleration while turning. Simultaneously, the vehicle motion can be stabilised. As a result, the proposed control method can ensure compatibility between vehicle dynamics performance and energy efficiency. This paper also describes the results of a full-vehicle simulation that was conducted to examine the effectiveness of the proposed DYC.

  18. Stochastic Optimization of Wind Turbine Power Factor Using Stochastic Model of Wind Power

    DEFF Research Database (Denmark)

    Chen, Peiyuan; Siano, Pierluigi; Bak-Jensen, Birgitte

    2010-01-01

    This paper proposes a stochastic optimization algorithm that aims to minimize the expectation of the system power losses by controlling wind turbine (WT) power factors. This objective of the optimization is subject to the probability constraints of bus voltage and line current requirements....... The optimization algorithm utilizes the stochastic models of wind power generation (WPG) and load demand to take into account their stochastic variation. The stochastic model of WPG is developed on the basis of a limited autoregressive integrated moving average (LARIMA) model by introducing a crosscorrelation...... structure to the LARIMA model. The proposed stochastic optimization is carried out on a 69-bus distribution system. Simulation results confirm that, under various combinations of WPG and load demand, the system power losses are considerably reduced with the optimal setting of WT power factor as compared...

  19. Voltage regulation and power losses reduction in a wind farm integrated MV distribution network

    Science.gov (United States)

    Fandi, Ghaeth; Igbinovia, Famous Omar; Tlusty, Josef; Mahmoud, Rateb

    2018-01-01

    A medium-voltage (MV) wind production system is proposed in this paper. The system applies a medium-voltage permanent magnet synchronous generator (PMSG) as well as MV interconnection and distribution networks. The simulation scheme of an existing commercial electric-power system (Case A) and a proposed wind farm with a gearless PMSG insulated gate bipolar transistor (IGBT) power electronics converter scheme (Case B) is compared. The analyses carried out in MATLAB/Simulink environment shows an enhanced voltage profile and reduced power losses, thus, efficiency in installed IGBT power electronics devices in the wind farm. The resulting wind energy transformation scheme is a simple and controllable medium voltage application since it is not restrained by the IGBT power electronics voltage source converter (VSC) arrangement. Active and reactive power control is made possible with the aid of the gearless PMSG IGBT power converters.

  20. Methodology for simulation of geomagnetically induced currents in power systems

    Directory of Open Access Journals (Sweden)

    Boteler David

    2014-07-01

    Full Text Available To assess the geomagnetic hazard to power systems it is useful to be able to simulate the geomagnetically induced currents (GIC that are produced during major geomagnetic disturbances. This paper examines the methodology used in power system analysis and shows how it can be applied to modelling GIC. Electric fields in the area of the power network are used to determine the voltage sources or equivalent current sources in the transmission lines. The power network can be described by a mesh impedance matrix which is combined with the voltage sources to calculate the GIC in each loop. Alternatively the power network can be described by a nodal admittance matrix which is combined with the sum of current sources into each node to calculate the nodal voltages which are then used to calculate the GIC in the transmission lines and GIC flowing to ground at each substation. Practical calculations can be made by superposition of results calculated separately for northward and eastward electric fields. This can be done using magnetic data from a single observatory to calculate an electric field that is a uniform approximation of the field over the area of the power system. It is also shown how the superposition of results can be extended to use data from two observatories: approximating the electric field by a linear variation between the two observatory locations. These calculations provide an efficient method for simulating the GIC that would be produced by historically significant geomagnetic storm events.

  1. Effect of selected factors on the current flow and voltage loss at ...

    African Journals Online (AJOL)

    In this paper, laboratory scale study was conducted to investigate the current flow and voltage loss at the electrodes in the electrochemical treatment of a tropical laterite. Three different tests using calcium chloride (CC) as anolyte and sodium chloride (SC) as catholyte (NC); SC as anolyte and Phosphoric acid (PA) as ...

  2. Winding Design for Minimum Power Loss and Low-Cost Manufacture in Application to Fixed-Speed PM Generator

    OpenAIRE

    Wrobel, Rafal; Staton, David; Lock, Richard J; Booker, Julian D; Drury, David

    2015-01-01

    This paper presents the results from a coupled thermal and power loss analysis of an open-slot permanent-magnet (PM) generator. The research focus has been placed on the winding design providing minimum power loss at an ac operation, together with low-cost manufacture. The analyzed PM generator is intended to operate at a fixed speed, allowing for the winding design to be finely tuned for a single operating point. Such a design approach has not been widely reported in literature, and the exis...

  3. Simulating the indirect effects of power plant entrainment losses on an estuarine ecosystem

    Energy Technology Data Exchange (ETDEWEB)

    Summers, J.K. (Versar, Inc., Columbia, MD (USA))

    1989-12-01

    Entrainment caused by the operation of the Chalk Point Steam Electric Station has been shown to be a major source of mortality to the early life stages of forage fish populations in the Patuxent River, MD, USA. While direct losses to these populations are important as a source of reduction for population abundance, these losses also represent decreases in estuarine forage supplies and potential reductions in the abundances of estuarine predators. A simple estuarine trophic dynamics model was constructed to determine the magnitude of the potential losses to major estuarine consumers in the Patuxent River ecosystem due to the power plant-related losses of forage fish. Simulations were completed using two sets of feeding assumptions: feeding proportional to forage abundance, and feeding based on dietary preferences. The model demonstrates that striped bass, bluefish, and weakfish could experience significant losses (> 25%) to overall population production levels if they prefer to prey upon bay anchovy and silversides and entrainment losses to these forage populations is {>=} 70% of juvenile recruitment. The model also shows that indirect predator losses would be expected to be low (> 5%) if the majority of their diets consisted of forage other than bay anchovy and silversides. 2 figs., 31 refs., 4 tabs.

  4. FY 2000 report on the development of ultra low loss power element technology. Commercialization of next generation power semiconductor device; 2000 nendo choteisonshitsu denryoku soshi gijutsu kaihatsu seika hokokusho. Jisedai power handotai device jitsuyoka chosa

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-03-01

    For the purpose of contributing to the promotion of development of ultra low loss power element technology, survey was conducted on the present situation, future, etc. of various technologies/systems related to power semiconductor devices. In the industrial equipment field, it is predicted that power semiconductor devices will be increased in the field of application by enlargement of the defense field of IGBT, new MOS structure elements, etc. In the field of home appliances, possibilities are expected of switching loss reduction and electric noise reduction by making SiC high speed diode. As to the space photovoltaic power generation, SiC is expected for various semiconductors such as solar cells, FET for transmitter/amplifier of radio power electric transmission use micro waves, etc. Concerning the radio communication system plan using stratosphere platform, there are technical problems on communication equipment such as antenna and RF circuit, and the role of SiC device is expected to be large. The society where the electrification rate is 80% and fuel cell vehicles are used is a new paradigm, and it is necessary and indispensable to commercialize ultra low loss power elements using SiC. (NEDO)

  5. Evolution of Onsite and Offsite Power Systems in US Nuclear Power Plants

    International Nuclear Information System (INIS)

    Mathew, Roy K.

    2015-01-01

    The AC electric power system is the source of power for station auxiliaries during normal operation and for the reactor protection system and emergency safety features during abnormal and accident conditions. Since the construction of early plants in US, the functional adequacy and requirements of the offsite power systems, safety and non safety related onsite electric power systems have changed considerably to ensure that these systems have adequate redundancy, independence, quality, maintenance and testability to support safe shutdown of the nuclear plant. The design of AC systems has evolved from a single train to multiple (up to four) redundant trains in the current evolutionary designs coupled with other auxiliary AC systems. The early plants were designed to cope with a Loss of Offsite Power (LOOP) event through the use of onsite power supplies only. However operating experience has indicated that onsite and offsite power AC power systems can fail due to natural phenomena (earthquakes, lightning strikes, fires, geomagnetic storms, tsunamis, etc.) or operational abnormalities such as loss of a single phase, switching surges or human error. The onsite DC systems may not be adequately sized to support plant safe shutdown over an extended period if AC power cannot be restored within a reasonable time. This paper will discuss the requirements to improve availability and reliability of offsite and onsite alternating current (AC) power sources to U.S. Nuclear Power Plants. In addition, the paper will discuss the requirements and guidance beyond design basis events. (author)

  6. Reliability of emergency alternating-current power systems at nuclear power plants: a discussion of NUREG/CR-2989

    International Nuclear Information System (INIS)

    Battle, R.E.

    1985-01-01

    The reliability of emergency alternating-current power systems typical of most nuclear power plants was estimated by using fault-tree analysis of selected typical designs. The failure probabilities used in the fault trees were calculated from extensive historical data collected from Licensee Event Reports and from operating experience information obtained from nuclear plant licensees. Trends of diesel generator independent failure on demand are included. No one or two improvements can be made at all plants to increase significantly the industry-average emergency alternating-current power system reliability; the most beneficial improvements are varied and plant specific

  7. On the Possibilities of Decreasing Power Loss in Large Tilting Pad Thrust Bearings

    OpenAIRE

    Wasilczuk, Michal; Rotta, Grzegorz

    2013-01-01

    Different systems of direct oil supply have been developed in order to facilitate efficient introduction of fresh lubricant to the oil gap and reduction of churning power loss in tilting pad thrust bearings. Up to now there is no documented application of the supply groove in large thrust bearings used in water power plants. The results of modeling lubricant flow in the lubricating groove of a thrust bearing pad will be presented in the paper. CFD software was used to carry out fluid film cal...

  8. RELAP5/MOD3.2 investigation of loss of in-house supply power for WWER 1000/320V

    International Nuclear Information System (INIS)

    Gencheva, R.; Pavlova, M.; Groudev, P.

    2001-01-01

    This paper discusses the results of the thermal-hydraulic investigations of the 'Loss of in-house supply power' accident at the Kozloduy NPP Unit 6. The RELAP5/MOD3.2 computer code has been used to stimulate the loss of in-house supply power accident in a WWER 1000 Nuclear Power Plant model. This model was developed at the Institute for Nuclear Research and Nuclear Energy for analyses of operational occurrences, abnormal events and design basis scenarios. It will provide a significant analytical capability for the Bulgarian technical specialists located at the Kozloduy NPP. The criteria used in selecting transient are: importance to safety, availability and suitability of data followed by suitability for RELAP5 code validation. The investigation of 'Loss of normal and reverse AC power' is a process that compares the analytical results obtained by RELAP5/MOD3.2 model of the WWER 1000 against experimental transient data obtained from Kozloduy NPP Unit 6. The comparisons between the RELAP5 results and the test data indicate good agreement

  9. Design and implementation of predictive filtering system for current reference generation of active power filter

    Energy Technology Data Exchange (ETDEWEB)

    Kilic, Tomislav; Milun, Stanko; Petrovic, Goran [FESB University of Split, Faculty of Electrical Engineering, Machine Engineering and Naval Architecture, R. Boskovica bb, 21000, Split (Croatia)

    2007-02-15

    The shunt active power filters are used to attenuate the harmonic currents in power systems by injecting equal but opposite compensating currents. Successful control of the active filters requires an accurate current reference. In this paper the current reference determination based on predictive filtering structure is presented. Current reference was obtained by taking the difference of load current and its fundamental harmonic. For fundamental harmonic determination with no time delay a combination of digital predictive filter and low pass filter is used. The proposed method was implemented on a laboratory prototype of a three-phase active power filter. The algorithm for current reference determination was adapted and implemented on DSP controller. Simulation and experimental results show that the active power filter with implemented predictive filtering structure gives satisfactory performance in power system harmonic attenuation. (author)

  10. A Technique to Estimate the Equivalent Loss Resistance of Grid-Tied Converters for Current Control Analysis and Design

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Fernandez, Francisco Daniel Freijedo

    2015-01-01

    Rigorous analysis and design of the current control loop in voltage source converters (VSCs) requires an accurate modeling. The loop behavior can be significantly influenced by the VSC working conditions. To consider such effect, converter losses should be included in the model, which can be done...... by means of an equivalent series resistance. This paper proposes a method to identify the VSC equivalent loss resistance for the proper tuning of the current control loop. It is based on analysis of the closed-loop transient response provided by a synchronous proportional-integral current controller......, according to the internal model principle. The method gives a set of loss resistance values linked to working conditions, which can be used to improve the tuning of the current controllers, either by online adaptation of the controller gains or by open-loop adaptive adjustment of them according to prestored...

  11. Tokamak power reactor ignition and time dependent fractional power operation

    International Nuclear Information System (INIS)

    Vold, E.L.; Mau, T.K.; Conn, R.W.

    1986-06-01

    A flexible time-dependent and zero-dimensional plasma burn code with radial profiles was developed and employed to study the fractional power operation and the thermal burn control options for an INTOR-sized tokamak reactor. The code includes alpha thermalization and a time-dependent transport loss which can be represented by any one of several currently popular scaling laws for energy confinement time. Ignition parameters were found to vary widely in density-temperature (n-T) space for the range of scaling laws examined. Critical ignition issues were found to include the extent of confinement time degradation by alpha heating, the ratio of ion to electron transport power loss, and effect of auxiliary heating on confinement. Feedback control of the auxiliary power and ion fuel sources are shown to provide thermal stability near the ignition curve

  12. 3D Analysis of Cooling Performance with Loss of Offsite Power Using GOTHIC Code

    International Nuclear Information System (INIS)

    Oh, Kye Min; Heo, Gyun Young; Na, In Sik; Choi, Yu Jung

    2010-01-01

    GOTHIC code enables to analyze one-dimensional or multi-dimensional problems for evaluating the cooling performance of loss of offsite power. The conventional GOTHIC code analysis performs heat transfer between plant containment and the outside of the fan cooler tubes by modeling each of fan cooler part model and component cooling water inside tube each to analyze boiling probability. In this paper, we suggest a way which reduces the multi-procedure of the cooling performance with loss of offsite power or the heat transfer states with complex geometrical structure to a single-procedure and verify the applicability of the heat transfer differences from the containment atmosphere humidity changes by the multi-nodes which component cooling water of tube or air of Reactor Containment Fan Cooler in the containment, otherwise the component model uses only one node

  13. Detection and analysis of thermal energy loss in the Atucha I nuclear power plant residual heat removal system

    International Nuclear Information System (INIS)

    Berra, Sandra; Guala, Mariana I.; Khon, Hector; Lorenzo, Andrea T.; Raffo Calderon, Maria C.; Urrutia, Guillermo

    1999-01-01

    It is presented the methodology used to detect and to measure energy losses which are existent in the Atucha I nuclear power plant. They were not directly detected, since the magnitude of those was below of the instrumentation precision which is used to measure the electric and thermal power in the plant. To achieve this work temperature special measurements were made. In this way it was possible to quantify the energy losses after operational long periods. (author)

  14. Development and experiment of a 60 kW horizontal-axis marine current power system

    International Nuclear Information System (INIS)

    Xu, Quan-kun; Liu, Hong-wei; Lin, Yong-gang; Yin, Xiu-xing; Li, Wei; Gu, Ya-jing

    2015-01-01

    A 60 kW horizontal-axis marine current power system is designed, built and tested to provide potentially cost-competitive electrical power for residents in remote islands. This power system mainly consists of a three-bladed marine current turbine, a drive-train system, power electronics and a control console. The turbine blade parameters are reasonably calculated and optimized based on the blade element momentum theory. The hydrodynamic performances of this turbine are predicted over a wide range of operating conditions. An adequate drive-train system is carefully designed to make the marine power system work smoothly and quietly even under harsh marine current conditions. The control console is also developed to facilitate the condition monitoring and generator power and speed regulations for this power system by adequately controlling the onshore power electronics. This power system has been tested under real marine current conditions to thoroughly evaluate its dynamic characteristics and effectiveness. - Highlights: • A 60°kW horizontal-axis marine current power system is designed, built and tested. • Detailed design procedure and experimental data are provided. • Experimental results demonstrate high power convention efficiency of the system

  15. Novel miniature high power ring filter

    International Nuclear Information System (INIS)

    Huang Huifen; Mao Junfa; Luo Zhihua

    2005-01-01

    The power handling capability of high temperature superconducting (HTS) filters is limited due to current concentration at the edges of the superconducting films. This problem can be overcome by using ring resonator, which employs the edge current free and reduces the current concentration. However, this kind of filter has large size. In order to reduce the cost and size and increase the power handling capability, in this paper a HTS photonic bandgap (PBG) structure filter is developed. The proposed pass band filter with PBG structure exhibits center frequency 12.23 GHz, steepness (about 35 dB/GHz), bandwidth (-3 dB bandwidth is 0.045 GHz), and low insertion loss (about -0.5 dB), and can handle input power up to 1 W (this value was limited by the measurement instrument used in the experiment). The size is reduced by 25%, insertion loss reduced by 37.5%, and steeper roll-off of the filter is also obtained compared with that in published literature

  16. Emissivity-corrected power loss calibration for lock-in thermography measurements on silicon solar cells

    International Nuclear Information System (INIS)

    Kasemann, Martin; Walter, Benjamin; Meinhardt, Christoph; Ebser, Jan; Kwapil, Wolfram; Warta, Wilhelm

    2008-01-01

    This paper describes power loss calibration procedures with implemented emissivity correction. The determination of our emissivity correction matrix does neither rely on blackbody reference measurements nor on the knowledge of any sample temperatures. To describe the emissivity-corrected power calibration procedures in detail, we review the theory behind lock-in thermography and show experimentally that the lock-in signal is proportional to the power dissipation in the solar cell. Experiments show the successful application of our emissivity correction procedure, which significantly improves the informative value of lock-in thermography images and the reliability of the conclusions drawn from these images

  17. Design considerations for high current regulated DC power supplies with reference to 600 kW variable DC power supply

    International Nuclear Information System (INIS)

    Ushakumari; Garud, A.N.; Nadkarni, S.S.

    1980-01-01

    High current regulated dc power supplies find increasing applications in industry and research. The power rating of these supplies vary from few killowatts to megawatts. The general requirements of these supplies for various applications and the techniques used to achieve the desired performance are presented. The design and selection of various circuit blocks namely the rectifier transformer, multiphase rectifier arrangement, SCR paralleling and current sensing techniques, are discussed in detail for a 600 killowatt current controlled supply developed in the Bhabha Atomic Research Centre, Bombay, and used for the thermal studies of reactor components. The power supply incorporates paralleled phase controlled thyristors with a closed loop feedback circuitary to achieve a current stability of 0.1% and smooth output variation from 10 to 100%. (auth.)

  18. ELECTRODYNAMICS OF TRANSMISSION AND LOSSES OF POWER IN THE DEVICES OF ELECTRIC TRACTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    M. O. Kostin

    2014-01-01

    Full Text Available Purpose. Theoretical justification of the "field" approach (based on electromagnetic field to the transmission and losses of power in the devices of traction power supply systems and electric rolling stock. Methodology. The methods of electromagnetic field theory and, in particular, the theory and practice of electromagnetic energy transmission based on the concept of the Poynting vector and elements of the theory of propagation, reflection and refraction of plane electromagnetic waves were used. Findings. Theoretical studies of electromagnetic energy transmission from the traction substation to the electric rolling stock through dielectric (air surrounding traction network: between the contact wire and the rail were carried out. It is proposed strategic designing "squat" (low types of electric rolling stock. The components of electric energy flow through the roof of electric rolling stock and its frontal part of the body were estimated. This allows reliable etimating active power losses in electric traction system. To compensate the reactive power consumed by electric rolling stock, which is conditioned by standing waves, it is proposed (for extinction of the the last to develop and put in front of electric rolling stock the layer of particular environment with the necessary parameters. Originality. The "field" principle of the power transmission analysis and its losses arising in electric traction system was first proposed. The laws of motion of electromagnetic energy flows through the roof and the frontal part of the body of electric rolling stock were established. Practical value. An expression of the absolute value of the Poynting vector in the points of dielectric (air between the contact wire and the rail was obtained. This allows assessing the highest density of energy, which is transferred to the time unit and predicting the main dimensions of the unit of electric rolling stock. The energy indices of the roof of electric rolling stock

  19. Implementation of superconducting fault current limiter for flexible operation in the power substation

    Energy Technology Data Exchange (ETDEWEB)

    Song, Chong Suk, E-mail: chong_suk@korea.ac.kr [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of); Lee, Hansang [School of Railway and Electrical Engineering, Kyungil University, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-701 (Korea, Republic of); Cho, Yoon-sung [Department of Electric and Energy Engineering, Catholic University of Daegu, Hayang-eup, Gyeongsan-si, Gyeongsangbuk-do 712-702 (Korea, Republic of); Suh, Jaewan [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of); Jang, Gilsoo, E-mail: gjang@korea.ac.kr [School of Electrical Engineering, Korea University, Anam dong, Seonbukgu, Seoul 136-713 (Korea, Republic of)

    2014-09-15

    Highlights: • The power load concentrated in load centers results in high levels of fault current. • This paper introduces a fault current reduction scheme using SFCLs in substations. • The SFCL is connected in parallel to the bus tie between the two busbars. • The fault current mitigation using SFCLs is verified through PSS/e simulations. - Abstract: The concentration of large-scale power loads located in the metropolitan areas have resulted in high fault current levels during a fault thereby requiring the substation to operate in the double busbar configuration mode. However, the double busbar configuration mode results in deterioration of power system reliability and unbalanced power flow in the adjacent transmission lines which may result in issues such as overloading of lines. This paper proposes the implementation of the superconducting fault current limiter (SFCL) to be installed between the two substation busbars for a more efficient and flexible operation of the substation enabling both single and double busbar configurations depending on the system conditions for guaranteeing power system reliability as well as fault current limitations. Case studies are being performed for the effectiveness of the SFCL installation and results are compared for the cases where the substation is operating in single and double busbar mode and with and without the installation of the SFCL for fault current mitigation.

  20. Additional Energy Losses from Asymmetric and Non-Sinusoidal Current in an Electrical Facility and Methods of their Reduction

    Directory of Open Access Journals (Sweden)

    Tarasov Evgeniy V.

    2015-01-01

    Full Text Available Influence of the asymmetry and higher harmonics of current on the operation of an electrical facility is analyzed. The level of additional losses from the asymmetric and non-sinusoidal currents is evaluated for a 110 kV electrical network in the Siberian Region of the Russian Federation. Methods for reducing the additional energy losses in the electrical facility are suggested.

  1. Additional Energy Losses from Asymmetric and Non-Sinusoidal Current in an Electrical Facility and Methods of their Reduction

    OpenAIRE

    Tarasov, Evgeny Vladimirovich; Bulyga, Leonid Leonidovich; Ushakov, Vasily Yakovlevich; Kharlov, Nikolay Nikolaevich

    2015-01-01

    Influence of the asymmetry and higher harmonics of current on the operation of an electrical facility is analyzed. The level of additional losses from the asymmetric and non-sinusoidal currents is evaluated for a 110 kV electrical network in the Siberian Region of the Russian Federation. Methods for reducing the additional energy losses in the electrical facility are suggested.

  2. Study of Power Loss Reduction in SEPR Converters for Induction Heating through Implementation of SiC Based Semiconductor Switches

    Directory of Open Access Journals (Sweden)

    Angel Marinov

    2014-08-01

    Full Text Available This paper presents a power loss analysis for a Single Ended Parallel Resonance (SEPR Converter used for induction heating. The analysis includes a comparison of the losses in the electronic switch when the circuit is realized using a conventional Silicon (Si based IGBT or when using Silicon Carbide (SiC based MOSFET. The analysis includes modelling and simulation as well as experimental verification through power loss and heat dissipation measurement. The presented results can be used as a base of comparison between the switches and can be a starting point for efficiency based design of those types of converters.

  3. Modeling and Maximum Power Point Tracking Control of Wind Generating Units Equipped with Permanent Magnet Synchronous Generators in Presence of Losses

    Directory of Open Access Journals (Sweden)

    Andrea Bonfiglio

    2017-01-01

    Full Text Available This paper focuses on the modeling of wind turbines equipped with direct drive permanent magnet synchronous generators for fundamental frequency power system simulations. Specifically, a procedure accounting for the system active power losses to initialize the simulation starting from the load flow results is proposed. Moreover, some analytical assessments are detailed on typical control schemes for fully rated wind turbine generators, thereby highlighting how active power losses play a fundamental role in the effectiveness of the wind generator control algorithm. Finally, the paper proposes analytical criteria to design the structure and the parameters of the regulators of the wind generator control scheme. Simulations performed with Digsilent Power Factory validated the proposed procedure, highlighting the impact of active power losses on the characterization of the initial steady state and that the simplifying assumptions done in order to synthesize the controllers are consistent with the complete modeling performed by the aforementioned power system simulator.

  4. Mini Solar and Sea Current Power Generation System

    Science.gov (United States)

    Almenhali, Abdulrahman; Alshamsi, Hatem; Aljunaibi, Yaser; Almussabi, Dheyab; Alshehhi, Ahmed; Hilal, Hassan Bu

    2017-07-01

    The power demand in United Arab Emirates is increased so that there is a consistent power cut in our region. This is because of high power consumption by factories and also due to less availability of conventional energy resources. Electricity is most needed facility for the human being. All the conventional energy resources are depleting day by day. So we have to shift from conventional to non-conventional energy resources. In this the combination of two energy resources is takes place i.e. wind and solar energy. This process reviles the sustainable energy resources without damaging the nature. We can give uninterrupted power by using hybrid energy system. Basically this system involves the integration of two energy system that will give continuous power. Solar panels are used for converting solar energy and wind turbines are used for converting wind energy into electricity. This electrical power can utilize for various purpose. Generation of electricity will be takes place at affordable cost. This paper deals with the generation of electricity by using two sources combine which leads to generate electricity with affordable cost without damaging the nature balance. The purpose of this project was to design a portable and low cost power system that combines both sea current electric turbine and solar electric technologies. This system will be designed in efforts to develop a power solution for remote locations or use it as another source of green power.

  5. Power loss and right ventricular efficiency in patients after tetralogy of Fallot repair with pulmonary insufficiency: clinical implications.

    Science.gov (United States)

    Fogel, Mark A; Sundareswaran, Kartik S; de Zelicourt, Diane; Dasi, Lakshmi P; Pawlowski, Tom; Rome, Jack; Yoganathan, Ajit P

    2012-06-01

    To quantify right ventricular output power and efficiency and correlate these to ventricular function in patients with repaired tetralogy of Fallot. This might aid in determining the optimal timing for pulmonary valve replacement. We reviewed the cardiac catheterization and magnetic resonance imaging data of 13 patients with tetralogy of Fallot (age, 22 ± 17 years). Using pressure and flow measurements in the main pulmonary artery, cardiac output and regurgitation fraction, right ventricular (RV) power output, loss, and efficiency were calculated. The RV function was evaluated using cardiac magnetic resonance imaging. The RV systolic power was 1.08 ± 0.62 W, with 20.3% ± 8.6% power loss owing to 41% ± 14% pulmonary regurgitation (efficiency, 79.7% ± 8.6%; 0.84 ± 0.73 W), resulting in a net cardiac output of 4.24 ± 1.82 L/min. Power loss correlated significantly with the indexed RV end-diastolic and end-systolic volume (R = 0.78, P = .002 and R = 0.69, P = .009, respectively). The normalized RV power output had a significant negative correlation with RV end-diastolic and end-systolic volumes (both R = -0.87, P = .002 and R = -0.68, P = .023, respectively). A rapid decrease occurred in the RV power capacity with an increasing RV volume, with the curve flattening out at an indexed RV end-diastolic and end-systolic volume threshold of 139 mL/m(2) and 75 mL/m(2), respectively. Significant power loss is present in patients with repaired tetralogy of Fallot and pulmonary regurgitation. A rapid decrease in efficiency occurs with increasing RV volume, suggesting that pulmonary valve replacement should be done before the critical value of 139 mL/m(2) and 75 mL/m(2) for the RV end-diastolic and end-systolic volume, respectively, to preserve RV function. Copyright © 2012 The American Association for Thoracic Surgery. Published by Mosby, Inc. All rights reserved.

  6. Influence of the CVCS Modelling on Results of the Loss of Offsite Power (LOOP) Safety Analysis for NPP Krsko

    International Nuclear Information System (INIS)

    Bencik, V.; Bajs, T.; Debrecin, N.

    2006-01-01

    A Loss of Offsite Power (LOOP) transient scenario is based on a complete loss of non-emergency AC power that results in the loss of all power to the plant auxiliaries, i.e., the Reactor Coolant Pumps (RCPs), condensate pumps, etc. An actual LOOP event would cause a loss of all feedwater, a loss of forced Reactor Coolant System (RCS) flow and a reactor trip within less than 2 seconds as a result of either loss of power to the rod cluster assembly gripper coils or any RCS flow trips. For safety analysis purposes the LOOP event is conservatively modelled as a Loss of Normal Feedwater (LONF) transient with a subsequent loss of offsite power as a result of a reactor trip. The reactor trip followed by RCP trip are delayed until a low-low Steam Generator (SG) level signal is reached. This is a more conservative scenario than the LOOP event because the least amount of SG secondary side water mass available for heat removal and the increased amount of the stored energy in the primary circuit at the time of the loss of RCS flow result. The standard LOOP safety analysis is aimed to demonstrate the natural circulation capability of the RCS to remove residual and decay heat from the core aided by Auxiliary Feedwater in the secondary system. In addition to this goal the presented work is aimed to resolve the potential safety issue resulting from the influence of the Chemical and Volume Control System (CVCS) operation during LOOP event for NPP Krsko. The potential safety concern for the LOOP analysis is that the loss of instrument air system may occur thus leading to the CVCS charging and letdown flow imbalance. A net RCS inventory addition may result with water solid pressurizer condition. Water discharge through the pressurizer relief and safety valves could lead to overpressurization of the Pressurizer Relief Tank (PRT) and rupture of the PRT rupture disks. Additional concern is that pressurizer relief and safety valves may fail to properly reseat when exposed to water relief

  7. Negative sequence current control in wind power plants with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2012-01-01

    Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for grid connection. The power electronic converters in theWTG-FSC and the VSC......-HVDC allow fast current control in the offshore grid. This paper presents a method of controlling the negative sequence current injection into the offshore grid from the VSC-HVDC as well as WTG-FSCs. This would minimize the power oscillations and hence reduce the dc voltage overshoots in the VSC-HVDC system...... as well as in the WTG-FSCs; especially when the offshore grid is unbalanced due to asymmetric faults. The formulation for negative sequence current injection is mathematically derived and then implemented in electromagnetic transients (EMT) simulation model. The simulated results show that the negative...

  8. RHF RELAP5 model and preliminary loss-of-offsite-power simulation results for LEU conversion

    Energy Technology Data Exchange (ETDEWEB)

    Licht, J. R. [Argonne National Laboratory (ANL), Argonne, IL (United States). Nuclear Engineering Div.; Bergeron, A. [Argonne National Laboratory (ANL), Argonne, IL (United States). Nuclear Engineering Div.; Dionne, B. [Argonne National Laboratory (ANL), Argonne, IL (United States). Nuclear Engineering Div.; Thomas, F. [Institut Laue-Langevin (ILL), Grenoble (Switzerland). RHF Reactor Dept.

    2014-08-01

    The purpose of this document is to describe the current state of the RELAP5 model for the Institut Laue-Langevin High Flux Reactor (RHF) located in Grenoble, France, and provide an update to the key information required to complete, for example, simulations for a loss of offsite power (LOOP) accident. A previous status report identified a list of 22 items to be resolved in order to complete the RELAP5 model. Most of these items have been resolved by ANL and the RHF team. Enough information was available to perform preliminary safety analyses and define the key items that are still required. Section 2 of this document describes the RELAP5 model of RHF. The final part of this section briefly summarizes previous model issues and resolutions. Section 3 of this document describes preliminary LOOP simulations for both HEU and LEU fuel at beginning of cycle conditions.

  9. Impacts of propagating, frustrated and surface modes on radiative, electrical and thermal losses in nanoscale-gap thermophotovoltaic power generators

    Science.gov (United States)

    Bernardi, Michael P.; Dupré, Olivier; Blandre, Etienne; Chapuis, Pierre-Olivier; Vaillon, Rodolphe; Francoeur, Mathieu

    2015-01-01

    The impacts of radiative, electrical and thermal losses on the performances of nanoscale-gap thermophotovoltaic (nano-TPV) power generators consisting of a gallium antimonide cell paired with a broadband tungsten and a radiatively-optimized Drude radiator are analyzed. Results reveal that surface mode mediated nano-TPV power generation with the Drude radiator outperforms the tungsten radiator, dominated by frustrated modes, only for a vacuum gap thickness of 10 nm and if both electrical and thermal losses are neglected. The key limiting factors for the Drude- and tungsten-based devices are respectively the recombination of electron-hole pairs at the cell surface and thermalization of radiation with energy larger than the cell absorption bandgap. A design guideline is also proposed where a high energy cutoff above which radiation has a net negative effect on nano-TPV power output due to thermal losses is determined. It is shown that the power output of a tungsten-based device increases by 6.5% while the cell temperature decreases by 30 K when applying a high energy cutoff at 1.45 eV. This work demonstrates that design and optimization of nano-TPV devices must account for radiative, electrical and thermal losses. PMID:26112658

  10. Wind Power Plant Voltage Stability Evaluation: Preprint

    Energy Technology Data Exchange (ETDEWEB)

    Muljadi, E.; Zhang, Y. C.

    2014-09-01

    Voltage stability refers to the ability of a power system to maintain steady voltages at all buses in the system after being subjected to a disturbance from a given initial operating condition. Voltage stability depends on a power system's ability to maintain and/or restore equilibrium between load demand and supply. Instability that may result occurs in the form of a progressive fall or rise of voltages of some buses. Possible outcomes of voltage instability are the loss of load in an area or tripped transmission lines and other elements by their protective systems, which may lead to cascading outages. The loss of synchronism of some generators may result from these outages or from operating conditions that violate a synchronous generator's field current limit, or in the case of variable speed wind turbine generator, the current limits of power switches. This paper investigates the impact of wind power plants on power system voltage stability by using synchrophasor measurements.

  11. Model Predictive Control of a Wave Energy Converter with Discrete Fluid Power Power Take-Off System

    Directory of Open Access Journals (Sweden)

    Anders Hedegaard Hansen

    2018-03-01

    Full Text Available Wave power extraction algorithms for wave energy converters are normally designed without taking system losses into account leading to suboptimal power extraction. In the current work, a model predictive power extraction algorithm is designed for a discretized power take of system. It is shown how the quantized nature of a discrete fluid power system may be included in a new model predictive control algorithm leading to a significant increase in the harvested power. A detailed investigation of the influence of the prediction horizon and the time step is reported. Furthermore, it is shown how the inclusion of a loss model may increase the energy output. Based on the presented results it is concluded that power extraction algorithms based on model predictive control principles are both feasible and favorable for use in a discrete fluid power power take-off system for point absorber wave energy converters.

  12. Hybrid Magnetics and Power Applications

    DEFF Research Database (Denmark)

    Mo, Wai Keung; Paasch, Kasper

    2017-01-01

    A hybrid magnetic approach, merging two different magnetic core properites such as ferrite and iron powder cores, is an effective solution for power converter applications. It can offer similar magnetic properties to that of magnetic powder cores but showing less copper loss than powder cores....... In order to prevent ferrite core saturation, placing an effective air gap within the ferrite core is a key method to obtain optimum hybrid magnetic performance. Furthermore, a relatively large inductance at low loading current is an excellent way to minimze power loss in order to achieve high efficiency...

  13. The influence of dew point during annealing on the power loss of electrical steel sheets

    Energy Technology Data Exchange (ETDEWEB)

    Broddefalk, Arvid [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden)], E-mail: arvid.broddefalk@sura.se; Jenkins, Keith [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden); Silk, Nick [Corus RD and T, Swinden Technology Centre, Moorgate Rotherham S60 3AR (United Kingdom); Lindenmo, Magnus [Development and Market Research, Cogent Power Ltd., P.O. Box 201, SE-735 23 Surahammar (Sweden)

    2008-10-15

    Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 deg. C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.

  14. The influence of dew point during annealing on the power loss of electrical steel sheets

    Science.gov (United States)

    Broddefalk, Arvid; Jenkins, Keith; Silk, Nick; Lindenmo, Magnus

    Decarburization is a necessary part of the processing of electrical steels if their carbon content is above a certain level. The process is usually carried out in a wet hydrogen-nitrogen atmosphere. Having a high dew point has a negative influence on the power loss, though. This is due to oxidation of the steel, which hinders domain wall motion near the surface. In this study, an increase of the power loss was only observed at a fairly high dew point (>20 °C). It was also only at these high dew points where a subsurface oxide layer was observed. The surfaces of samples with and without this layer were etched in steps. The magnetic properties of the etched samples corresponded well with the expected behavior based on GDOES profiles of the samples.

  15. Design of the power supply system for the plasma current modulation on J-TEXT tokamak

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, M.; Shao, J.; Ma, S.X., E-mail: mashaoxiang@hust.edu.cn; Liang, X.; Yu, K.X.; Pan, Y.

    2016-10-15

    Highlights: • A modification scheme of heating field power supply system for plasma current modulation. • High-power fast control power supply with multilevel cascade circuit. • Restraining circulating current with coupled inductors in cyclic symmetric structure. - Abstract: In order to further study the influence of current modulation parameters on suppressing tearing instability, the plasma current should be modulated in a wider range. So a modification scheme is designed to improve the performance of ohmic heating power supply system on J-TEXT tokamak. A multilevel cascade circuit with carrier phase-shifted PWM technique has been proposed. Coupled inductors are connected in the form of cyclic symmetry to restrain the circulating current caused by multiple paralleled branches. The simulation proves this proposed current modulation power supply system matches output requirement and achieves good current sharing effect. Finally, a prototype is designed, and the experiment results can verify the correctness of the simulation model well.

  16. On geomagnetically-induced currents in the Finnish 400 kV power system by an auroral electrojet current

    International Nuclear Information System (INIS)

    Pirjola, R.; Viljanen, A.

    1989-01-01

    The auroral electrojet current flowing in the ionosphere is modeled by a horizontal east-west line current of infinite length. The earth is described by a simple two-layer model. An expression for the earth-surface electric field, which is thus connected with a geomagnetic disturbance in and near the auroral zone, is given. This electric field is considered as external from the viewpoint of the Finnish 400 kV power system, and the resulting geomagnetically-induced currents (GICs) in the system are computed. In the north, i.e. near the electrojet, GICs may have values even in the order of hundreds of amperes. A comparison to GICs produced by an equivalent spatially-constant external electric field is demonstrated. Sometimes the location of the electrojet is further south. This possibility is studied by letting the line current have several different locations above the Finnish power grid

  17. Comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, S.

    2009-07-01

    During the past two decades, active power filters have increasingly grown their popularity as a viable method for improving electric power quality. The main reasons for this have been the advent of fast self-commutating solid-state devices, the progression of digital technology and the improved sensor technology. Four-wire active power filters provide an efficient solution for improving the quality of supply in grounded three-phase systems or three-phase systems with neutral conductors, which are commonly used for powering residential, office and public buildings. Four-wire active power filters are applicable in compensating current harmonics, reactive power, neutral current and load phase imbalance.This thesis presents a comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters. The study includes two voltage source topologies and a current source topology with two different dc-link energy storage structures, which are compared on the basis of their filtering properties, filtering performance and efficiency. The obtained results are used for determining the suitability of current source technology for four-wire active power filtering and finding the most viable four-wire shunt active power filter topology. One commonly recognized disadvantage of the current source active power filter has always been the bulky dc-link inductor. To reduce the size of the dc-link inductor, an alternative dc-link structure for current source active power filters was introduced in the late 80's. The hybrid energy storage consists of both inductive and capacitive energy storage elements, two diodes and two controllable semiconductor switching devices. Since the capacitive element is used as a main storage unit, the inductance of the dc-link inductor can be considerably reduced. However, the original dc current control method proposed is not able to utilize the full potential of the hybrid energy storage and the inductance

  18. A 2D finite element study on the role of material properties on eddy current losses in soft magnetic composites

    Science.gov (United States)

    Ren, Xiaotao; Corcolle, Romain; Daniel, Laurent

    2016-02-01

    The use of soft magnetic composites (SMCs) in electrical engineering applications is growing. SMCs provide an effective alternative to laminated steels because they exhibit a high permeability with low eddy current losses. Losses are a critical feature in the design of electrical machines, and it is necessary to evaluate the role of microstructure and constitutive properties of SMCs during the predesign stage. In this paper we propose a simplified finite element approach to compute eddy current losses in these materials. The computations allow to quantify the role of exciting source and material properties on eddy current losses. This analysis can later be used in the development of homogenization models for SMC. Contribution to the topical issue "Numelec 2015 - Elected submissions", edited by Adel Razek

  19. Comparison of AC losses, magnetic field/current distributions and critical currents of superconducting circular pancake coils and infinitely long stacks using coated conductors

    Energy Technology Data Exchange (ETDEWEB)

    Yuan Weijia; Campbell, A M; Hong, Z; Ainslie, M D; Coombs, T A, E-mail: wy215@cam.ac.u [Electronic, Power and Energy Conversion Group, Electrical Engineering Division, Engineering Department, University of Cambridge, Cambridge CB3 0FA (United Kingdom)

    2010-08-15

    A model is presented for calculating the AC losses, magnetic field/current density distribution and critical currents of a circular superconducting pancake coil. The assumption is that the magnetic flux lines will lie parallel to the wide faces of tapes in the unpenetrated area of the coil. Instead of using an infinitely long stack to approximate the circular coil, this paper gives an exact circular coil model using elliptic integrals. A new efficient numerical method is introduced to yield more accurate and fast computation. The computation results are in good agreement with the assumptions. For a small value of the coil radius, there is an asymmetry along the coil radius direction. As the coil radius increases, this asymmetry will gradually decrease, and the AC losses and penetration depth will increase, but the critical current will decrease. We find that if the internal radius is equal to the winding thickness, the infinitely long stack approximation overestimates the loss by 10% and even if the internal radius is reduced to zero, the error is still only 60%. The infinitely long stack approximation is therefore adequate for most practical purposes. In addition, the comparison result shows that the infinitely long stack approximation saves computation time significantly.

  20. Improvement of Power Flow Calculation with Optimization Factor Based on Current Injection Method

    Directory of Open Access Journals (Sweden)

    Lei Wang

    2014-01-01

    Full Text Available This paper presents an improvement in power flow calculation based on current injection method by introducing optimization factor. In the method proposed by this paper, the PQ buses are represented by current mismatches while the PV buses are represented by power mismatches. It is different from the representations in conventional current injection power flow equations. By using the combined power and current injection mismatches method, the number of the equations required can be decreased to only one for each PV bus. The optimization factor is used to improve the iteration process and to ensure the effectiveness of the improved method proposed when the system is ill-conditioned. To verify the effectiveness of the method, the IEEE test systems are tested by conventional current injection method and the improved method proposed separately. Then the results are compared. The comparisons show that the optimization factor improves the convergence character effectively, especially that when the system is at high loading level and R/X ratio, the iteration number is one or two times less than the conventional current injection method. When the overloading condition of the system is serious, the iteration number in this paper appears 4 times less than the conventional current injection method.

  1. Quality of the current low power and shutdown PSA practice

    International Nuclear Information System (INIS)

    Jang, Seung Cheol; Park, Jin Hee; Lim, Ho Gon; Kim, Tae Woon

    2004-01-01

    A probabilistic safety assessment (PSA) for the low-power and shutdown (LPSD) modes in a Korea standard nuclear power plant (KSNP) has been performed for the purpose of estimating the LPSD risk and identifying the vulnerabilities of LPSD operations. Both the operational experience and PSA results indicate that the risks from LPSD operations could be comparable with those from power operations. However, the application of the LPSD risk insights to risk-informed decision making has been slow to be adopted in practice. It is largely due to the question of whether the current LPSD PSA practice is appropriate for application to risk-informed decision making or not. Such a question has to do with the quality of the current LPSD PSA practice. In this paper, we have performed self-assessment of the KSNP LPSD PSA quality based on the ANS Standard (draft as of 13 Sep. 2002). The aims of the work are to find the LPSD PSA technical areas insufficient for application to risk-informed decision making and to efficiently allocate the limited research resources to improve the LPSD PSA model quality. Many useful findings regarding the current LPSD PSA quality are presented in this paper

  2. Loss-of-benefits analysis for nuclear power plant shutdowns: methodology and illustrative case study

    International Nuclear Information System (INIS)

    Peerenboom, J.P.; Buehring, W.A.; Guziel, K.A.

    1983-11-01

    A framework for loss-of-benefits analysis and a taxomony for identifying and categorizing the effects of nuclear power plant shutdowns or accidents are presented. The framework consists of three fundamental steps: (1) characterizing the shutdown; (2) identifying benefits lost as a result of the shutdown; and (3) quantifying effects. A decision analysis approach to regulatory decision making is presented that explicitly considers the loss of benefits. A case study of a hypothetical reactor shutdown illustrates one key loss of benefits: net replacement energy costs (i.e., change in production costs). Sensitivity studies investigate the responsiveness of case study results to changes in nuclear capacity factor, load growth, fuel price escalation, and discount rate. The effects of multiple reactor shutdowns on production costs are also described

  3. Regression and tracing methodology based prediction of oncoming demand and losses in deregulated operation of power systems

    DEFF Research Database (Denmark)

    Nallagownden, P.; Mukerjee, R.N.; Masri, S.

    2010-01-01

    of the transmission services hiring contract, inputs such as extent of use of a transmission circuit for a transaction and the associated power loss in the said transmission circuit are also required. To provide the necessary lead time to frame transaction and transmission contracts for an oncoming operational...... coefficients are used advantageously to predict a generator's contribution to a retailer's demand and power loss for this transaction. This paper proposes a procedure that can be implemented real time, to quantify losses in each transmission circuit used by a specific transaction, based on proportionality......The deregulated electricity market can be thought of as a conglomeration of generation providers, transmission service operators (TSO) and retailers, where both generation and retailing may have open access to the transmission grid for trading electricity. For a transaction contract bid to take...

  4. Current earthquake engineering practice for Japanese nuclear power plants

    International Nuclear Information System (INIS)

    Hofmayer, C.H.; Park, Y.J.; Costello, J.F.

    1992-01-01

    This paper provides a brief overview of seismic research being conducted in Japan and describes USNRC efforts to understand Japanese seismic practice. Current earthquake engineering practice for Japanese nuclear power plants is descried in JEAG 4601-1987, ''Technical Guidelines for Aseismic Design of Nuclear Power Plants.'' The USNRC has sponsored BNL to translate this document into English. Efforts are underway to study and understand JEAG 4601-1987 and make the translation more readily available in the United States

  5. Radiation-induced off-state leakage current in commercial power MOSFETs

    International Nuclear Information System (INIS)

    Dodd, Paul Emerson; Shaneyfelt, Marty Ray; Draper, Bruce Leroy; Felix, James Andrew; Schwank, James Ralph; Dalton, Scott Matthew

    2005-01-01

    The total dose hardness of several commercial power MOSFET technologies is examined. After exposure to 20 krad(SiO 2 ) most of the n- and p-channel devices examined in this work show substantial (2 to 6 orders of magnitude) increases in off-state leakage current. For the n-channel devices, the increase in radiation-induced leakage current follows standard behavior for moderately thick gate oxides, i.e., the increase in leakage current is dominated by large negative threshold voltage shifts, which cause the transistor to be partially on even when no bias is applied to the gate electrode. N-channel devices biased during irradiation show a significantly larger leakage current increase than grounded devices. The increase in leakage current for the p-channel devices, however, was unexpected. For the p-channel devices, it is shown using electrical characterization and simulation that the radiation-induced leakage current increase is related to an increase in the reverse bias leakage characteristics of the gated diode which is formed by the drain epitaxial layer and the body. This mechanism does not significantly contribute to radiation-induced leakage current in typical p-channel MOS transistors. The p-channel leakage current increase is nearly identical for both biased and grounded irradiations and therefore has serious implications for long duration missions since even devices which are usually powered off could show significant degradation and potentially fail.

  6. Starting characteristics of direct current motors powered by solar cells

    Science.gov (United States)

    Singer, S.; Appelbaum, J.

    1989-01-01

    Direct current motors are used in photovoltaic systems. Important characteristics of electric motors are the starting to rated current and torque ratios. These ratios are dictated by the size of the solar cell array and are different for the various dc motor types. Discussed here is the calculation of the starting to rated current ratio and starting to rated torque ratio of the permanent magnet, and series and shunt excited motors when powered by solar cells for two cases: with and without a maximum-power-point-tracker (MPPT) included in the system. Comparing these two cases, one gets a torque magnification of about 3 for the permanent magnet motor and about 7 for other motor types. The calculation of the torques may assist the PV system designer to determine whether or not to include an MPPT in the system.

  7. Predicting AC loss in practical superconductors

    International Nuclear Information System (INIS)

    Goemoery, F; Souc, J; Vojenciak, M; Seiler, E; Klincok, B; Ceballos, J M; Pardo, E; Sanchez, A; Navau, C; Farinon, S; Fabbricatore, P

    2006-01-01

    Recent progress in the development of methods used to predict AC loss in superconducting conductors is summarized. It is underlined that the loss is just one of the electromagnetic characteristics controlled by the time evolution of magnetic field and current distribution inside the conductor. Powerful methods for the simulation of magnetic flux penetration, like Brandt's method and the method of minimal magnetic energy variation, allow us to model the interaction of the conductor with an external magnetic field or a transport current, or with both of them. The case of a coincident action of AC field and AC transport current is of prime importance for practical applications. Numerical simulation methods allow us to expand the prediction range from simplified shapes like a (infinitely high) slab or (infinitely thin) strip to more realistic forms like strips with finite rectangular or elliptic cross-section. Another substantial feature of these methods is that the real composite structure containing an array of superconducting filaments can be taken into account. Also, the case of a ferromagnetic matrix can be considered, with the simulations showing a dramatic impact on the local field. In all these circumstances, it is possible to indicate how the AC loss can be reduced by a proper architecture of the composite. On the other hand, the multifilamentary arrangement brings about a presence of coupling currents and coupling loss. Simulation of this phenomenon requires 3D formulation with corresponding growth of the problem complexity and computation time

  8. Power Loss Analysis and Comparision of DC and AC Side Decoupling Module in a H-bridge Inverter

    DEFF Research Database (Denmark)

    Ma, Siyuan; Wang, Haoran; Zhu, Guorong

    2016-01-01

    perspective. The analytical power loss models are derived based on the operation principles of the active power decoupling methods. A comparative study is performed based on a 500 W single-phase H-bridge inverter study case with 400 V DC-link voltage level. The results provide a guideline to justify whether...

  9. High-current Standing Wave Linac With Gyrocon Power Source

    CERN Document Server

    Karliner, M M; Makarov, I G; Nezhevenko, O A; Ostreiko, G N; Persov, B Z; Serdobintsev, G V

    2004-01-01

    A gyrocon together with high-voltage 1.5 MeV accelerator ELIT-3A represents a power generator at 430 MHz serving for linear electron accelerator pulse driving. The facility description and results of calorimetric measurements of ELIT-3A electron beam power and accelerated beam at the end of accelerator are presented in the paper. 2.2 amps of pulsed current have been obtained at electron energy of 20 MeV. The achieved energy conversion efficiency is about 55%.

  10. Regulated-current dc power supply for gaseous-discharge lamps

    Science.gov (United States)

    Freeman, W.; Huguenin, D.

    1970-01-01

    Controlled current source having a high output resistance feeds continuous-flow hydrogen lamps in vacuum-ultraviolet photometric equipment. The power supply, also used with low-pressure sealed lamps, has a short recovery time and smooth regulation without overshoot.

  11. Fiscal 1998 research report on the total electric power loss reduction project for Myanmer; 1998 nendo Myanmer koku denryoku soshitsu sogo teigen project chosa hokokusho

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-03-01

    As a part of Japanese clean development mechanism, study was made on reduction of greenhouse effect gas emission from thermal power plants by reduction of power transmission and distribution losses of power systems in Myanmer. Study was made on technical power transmission and distribution losses for the national grid transmission system, 33kV sub- transmission system of Thaketa substation in Yangong city, and 6.6kV and 400V distribution systems of Latha and Lanmadaw townships in the downtown area of Yangong. Countermeasures for power loss reduction were considered on the basis of the study result. The loss reduction project plan includes a construction cost of 5,134,000US$, loss reduction of 7,726kW, and loss reduction of 33,213,000kWh. The project feasibility and profitability were evaluated by comparison between a financial internal rate of return (FIRR) and an opportunity cost assuming that a discount rate is the opportunity cost. As a result, FIRR was 17.36% and the discount rate was 8.89% in Myanmer. (NEDO)

  12. A Novel Sliding Mode Control Technique for Indirect Current Controlled Active Power Filter

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    2012-01-01

    Full Text Available A novel sliding mode control (SMC method for indirect current controlled three-phase parallel active power filter is presented in this paper. There are two designed closed loops in the system: one is the DC voltage controlling loop and the other is the reference current tracking loop. The first loop with a PI regulator is used to control the DC voltage approximating to the given voltage of capacitor, and the output of PI regulator through a low-pass filter is applied as the input of the power supply reference currents. The second loop implements the tracking of the reference currents using integral sliding mode controller, which can improve the harmonic treating performance. Compared with the direct current control technique, it is convenient to be implemented with digital signal processing system because of simpler system structure and better harmonic treating property. Simulation results verify that the generated reference currents have the same amplitude with the load currents, demonstrating the superior harmonic compensating effects with the proposed shunt active power filter compared with the hysteresis method.

  13. Numerical simulation of the plasma current quench following a disruptive energy loss

    International Nuclear Information System (INIS)

    Strickler, D.J.; Peng, Y.K.M.; Holmes, J.A.; Miller, J.B.; Rothe, K.E.

    1983-11-01

    The plasma electromagnetic interaction with poloidal field coils and nearby passive conductor loops during the current quench following a disruptive loss of plasma energy is simulated. By solving a differential/algebraic system consisting of a set of circuit equations (including the plasma circuit) coupled to a plasma energy balance equation and an equilibrium condition, the electromagnetic consequences of an abrupt thermal quench are observed. Limiters on the small and large major radium sides of the plasma are assumed to define the plasma cross section. The presence of good conductors near the plasma and a small initial distance (i.e., 5 to 10% of the plasma minor radius) between the plasma edge and an inboard limiter are shown to lead to long current decay times. For a plasma with an initial major radius R/sub o/ = 4.3 m, aspect ratio A = 3.6, and current I/sub P/ = 4.0 MA, introducing nearby passive conductors lengthens the current decay from milliseconds to hundreds of milliseconds

  14. Synchrotron radiation losses in Engineering Test Reactors (ETRs)

    International Nuclear Information System (INIS)

    Uckan, N.A.

    1987-11-01

    In next-generation Engineering Test Reactors (ETRs), one major objective is envisioned to be a long-pulse or steady-state burn using noninductive current drive. At the high temperatures needed for efficient current drive, synchrotron radiation could represent a large power loss, especially if wall reflectivity (R) is very low. Many INTOR-class ETR designs [Fusion Engineering Reactor (FER), Next European Torus (NET), OTR, Tokamak Ignition/Burn Engineering Reactor (TIBER), etc.] call for carbon-covered surfaces for which wall reflectivity is uncertain. Global radiation losses are estimated for these devices using empirical expressions given by Trubnikov (and others). Various operating scenarios are evaluated under the assumption that the plasma performance is limited by either the density limit (typical of the ignition phase) or the beta limit (typical of the current drive phase). For a case with ≥90% wall reflectivity, synchrotron radiation is not a significant contribution to the overall energy balance (the ratio of synchrotron to alpha power is less than 10 to 20%, even at ∼ 30 keV) and thus should not adversely alter performance in these devices. In extreme cases with 0% wall reflectivity, the ratio of synchrotron radiation to alpha power may approach 30 to 60% (depending on the device and limiting operating scenario), adversely affecting the performance characteristics. 12 refs., 7 tabs

  15. Design of constant current charging power supply for J-TEXT ohmic field capacitor banks

    International Nuclear Information System (INIS)

    Lv Shudong; Zhang Ming; Rao Bo; Yu Kexun; Yang Cheng

    2014-01-01

    The charging characteristic of the capacitor charging power supply was analyzed with practical series resonant topology. The method that setting two current taps and regulating PWM switching frequency was putted forward with close loop controlling algorithm to charge the multi-group capacitor banks with constant current. A capacitor charging power supply with the max output current 6.5 A and the max output voltage 2000 V is designed. Experimental results show that, this power supply can charge the four capacitor banks to any four different voltages in 1 minute with charging accuracy less than 1%, and meet the requirements of J-TEXT ohmic field power system. (authors)

  16. Design Provisions for Withstanding Station Blackout at Nuclear Power Plants

    International Nuclear Information System (INIS)

    2015-08-01

    International operating experience has shown that the loss of off-site power supply concurrent with a turbine trip and unavailability of the standby alternating current power system is a credible event. Lessons learned from the past and recent station blackout events, as well as the analysis of the safety margins performed as part of the ‘stress tests’ conducted on European nuclear power plants in response to the Fukushima Daiichi accident, have identified the station blackout event as a limiting case for most nuclear power plants. The magnitude 9.0 earthquake and consequential tsunami which occurred in Fukushima, Japan, in March 2011, led to a common cause failure of on-site alternating current electrical power supply systems at the Fukushima Daiichi nuclear power plant as well as the off-site power grid. In addition, the resultant flooding caused the loss of direct current power supply, which further exacerbated an already critical situation at the plant. The loss of electrical power resulted in the meltdown of the core in three reactors on the site and severely restricted heat removal from the spent fuel pools for an extended period of time. The plant was left without essential instrumentation and controls, and this made accident management very challenging for the plant operators. The operators attempted to bring and maintain the reactors in a safe state without information on the vital plant parameters until the power supply was eventually restored after several days. Although the Fukushima Daiichi accident progressed well beyond the expected consequences of a station blackout, which is the complete loss of all alternating current power supplies, many of the lessons learned from the accident are valid. A failure of the plant power supply system such as the one that occurred at Fukushima Daiichi represents a design extension condition that requires management with predesigned contingency planning and operator training. The extended loss of all power at a

  17. Approximative calculation of transient short-circuit currents in power-systems

    Energy Technology Data Exchange (ETDEWEB)

    Heuck, K; Rosenberger, R; Dettmann, K D; Kegel, R

    1986-08-01

    The paper shows that it is approximatively possible to calculate the transient short-circuit currents for symmetrical and asymmetrical faults in power-systems. For that purpose a simple equivalent network is found. Its error of approximation is small. For the important maximum short-circuit current limits of error are pointed out compared to VDE 0102.

  18. Self-field AC losses in Bi-2223 superconducting tapes

    International Nuclear Information System (INIS)

    Mueller, K. H.; Leslie, K.E.

    1996-01-01

    Full text: The self-field AC loss in Bi-2223 silver sheathed tapes for AC currents of up to 100 A was measured at 77 K and frequencies of 60 Hz and 600 Hz using a lock-in amplifier. The frequency dependence indicated a purely hysteretic loss which can be well described in terms of the critical state model for a flat superconducting strip. The only parameter needed to predict the self-field AC loss is the critical current of the critical state. Because the loss voltage is extremely small compared with the inductive voltage, a very high accuracy of the lock-in amplifier phase setting is required. Unlike in loss measurements on cylindrical superconducting samples, in the case of the tape the measuring circuit leads have to be brought out from the surface forming a loop where the changing magnetic field induces an additional voltage. Only if the loop formed by the leads at the voltage tabs is large enough will the apparent power dissipation approach the real AC loss associated with the length of the sample probed

  19. Loss of integrated control system power and overcooling transient at Rancho Seco on December 26, 1985

    International Nuclear Information System (INIS)

    1986-02-01

    On December 26, 1985, Rancho Seco Nuclear Generating Station, located in Clay, California, about 25 miles southeast of Sacramento, experienced a loss of dc power within the integrated control system (ICS) while the plant was operating at 76% power. The plant is owned by the Sacramento Municipal Utility District (SMUD). Following the loss of ICS dc power, the reactor tripped on high reactor coolant system (RCS) pressure followed by a rapid overcooling transient and automatic initiation of the safety features actuation system on low RCS pressure. The overcooling transient continued until ICS dc power was restored 26 minutes after its loss. The fundamental causes for this transient were design weaknesses and vulnerabilities in the ICS and in the equipment controlled by that system. These weaknesses and vulnerabilities were not adequately compensated by other design features, plant procedures or operator training. These weaknesses and vulnerabilities were largely known to SMUD and the NRC staff by virtue of a number of precursor events and through related analyses and studies. Yet, adequate plant modifications were not made so that this event would be improbable, or so that its course or consequences would be altered significantly. The information was available and known which could have prevented this overcooling transient; but in the absence of adequate plant modifications, the incident should have been expected. The report includes findings and conclusions of the NRC Incident Investigation Team sent to Rancho Seco by the NRC Executive Director for Operations in conformance with NRC's recently established Incident Investigation Program. 33 figs

  20. The effects of solar-geomagnetically induced currents on electrical systems in nuclear power stations

    International Nuclear Information System (INIS)

    Subudhi, M.; Carroll, D.P.; Kasturi, S.

    1994-01-01

    This report presents the results of a study to evaluate the potential effects of geomagnetically induced currents (GICs) caused by the solar disturbances on the in-plant electrical distribution system and equipment in nuclear power stations. The plant-specific electrical distribution system for a typical nuclear plant is modeled using the ElectroMagnetic Transient Program (EMTP). The computer model simulates online equipment and loads from the station transformer in the switchyard of the power station to the safety-buses at 120 volts to which all electronic devices are connected for plant monitoring. The analytical model of the plant's electrical distribution system is studied to identify the transient effects caused by the half-cycle saturation of the station transformers due to GIC. This study provides results of the voltage harmonics levels that have been noted at various electrical buses inside the plant. The emergency circuits appear to be more susceptible to high harmonics due to the normally light load conditions. In addition to steady-state analysis, this model was further analyzed simulating various plant transient conditions (e.g., loss of load or large motor start-up) occurring during GIC events. Detail models of the plant's protective relaying system employed in bus transfer application were included in this model to study the effects of the harmonic distortion of the voltage input. Potential harmonic effects on the uniterruptable power system (UPS) are qualitatively discussed as well

  1. New Pulsed Power Technology for High Current Accelerators

    International Nuclear Information System (INIS)

    Caporaso, G J

    2002-01-01

    Recent advances in solid-state modulators now permit the design of a new class of high current accelerators. These new accelerators will be able to operate in burst mode at frequencies of several MHz with unprecedented flexibility and precision in pulse format. These new modulators can drive accelerators to high average powers that far exceed those of any other technology and can be used to enable precision beam manipulations. New insulator technology combined with novel pulse forming lines and switching may enable the construction of a new type of high gradient, high current accelerator. Recent developments in these areas will be reviewed

  2. Maximum power point tracking for PV systems under partial shading conditions using current sweeping

    International Nuclear Information System (INIS)

    Tsang, K.M.; Chan, W.L.

    2015-01-01

    Highlights: • A novel approach for tracking the maximum power point of photovoltaic systems. • Able to handle both the uniform insolation and partial shading conditions. • Maximum power point tracking based on current sweeping. - Abstract: Partial shading on photovoltaic (PV) arrays causes multiple peaks on the output power–voltage characteristic curve and local searching technique such as perturb and observe (P&O) method could easily fail in searching for the global maximum. Moreover, existing global searching techniques are still not very satisfactory in terms of speed and implementation complexity. In this paper, a fast global maximum power point (MPPT) tracking method which is using current sweeping for photovoltaic arrays under partial shading conditions is proposed. Unlike conventional approach, the proposed method is current based rather than voltage based. The initial maximum power point will be derived based on a current sweeping test and the maximum power point can be enhanced by a finer local search. The speed of the global search is mainly governed by the apparent time constant of the PV array and the generation of a fast current sweeping test. The fast current sweeping test can easily be realized by a DC/DC boost converter with a very fast current control loop. Experimental results are included to demonstrate the effectiveness of the proposed global searching scheme

  3. Losses compensation; Compensation des pertes

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2001-07-01

    One mission of RTE (Electric Power Transportation), is to watch over the losses compensation resulting from the power transport on the electric power network. Since january 2001, RTE makes good the electric losses by the purchase of energy. To choose the marketers, a consultation has been realized by RTE. This document presents the rules concerning these losses compensation. (A.L.B.)

  4. Addressing Circuitous Currents MVDC Power Systems Protection

    Science.gov (United States)

    2017-12-31

    Addressing Circuitous Currents MVDC Power Systems Protection 5b. GRANT NUMBER N00014-16-1-3113 5c. PROGRAM ELEMENT NUMBER 6. AUTHOR($) Sd. PROJECT NUMBER...efficiency. A challenge with DC distribution is electrical protection . Z-source DC breakers alt! an pti n b&i g cvr.sidcrcd and this w rk ~xplores...zonal distribution, electric ship 16. SECURITY CLASSIFICATION OF: 17. LIMITATION OF a. REPORT b. ABSTRACT c. THIS PAGE ABSTRACT u u u uu 18. NUMBER

  5. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2006-01-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 μm thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance

  6. Experiment of enhancing critical current and reducing ac loss in pancake coil comprised of Ni-coated Bi-2223/Ag tape

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China); Han, Z. [Department of Physics, Applied Superconductivity Research Center, Tsinghua University, Beijing 100084 (China)

    2006-07-01

    An approach of realizing high performance HTS coil comprised of ferromagnetic material-coated BSCCO tape is proposed. The concept of influencing critical current and ac loss is based on the magnetic shielding effect resulting in redirection of self-field flux-lines. In the previous article, ac performance of Ni-coated tape was demonstrated where the Ni-coating was introduced at the edge-regime of the finished tape in order to redirect the perpendicular component of self-field lines. In order to investigate the shielding effect on ac performance in HTS coil, a two-turn pancake coil comprised of Ni-coated Bi-2223/Ag tape is demonstrated in the present article. About 6.4% of critical current was enhanced and 30% of transport current ac loss was reduced by means of 40 {mu}m thick and 0.3 mm long (from the edge toward center of the tape) Ni-coating. This result suggests that additional ferromagnetic loss could be compensated well by the shielding effect of the partial Ni-coating. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the volume and geometry of ferromagnetic coating introduced. Therefore, it is very important to control the parameter of ferromagnetic coating of the tape in order to balance the critical current and ac loss for optimum coil performance.

  7. An analytical turn-on power loss model for 650-V GaN eHEMTs

    DEFF Research Database (Denmark)

    Shen, Yanfeng; Wang, Huai; Shen, Zhan

    2018-01-01

    This paper proposes an improved analytical turn-on power loss model for 650-V GaN eHEMTs. The static characteristics, i.e., the parasitic capacitances and transconductance, are firstly modeled. Then the turn-on process is divided into multiple stages and analyzed in detail; as results, the time-d...

  8. Polarization retention loss in PbTiO3 ferroelectric films due to leakage currents

    NARCIS (Netherlands)

    Morelli, A.; Venkatesan, Sriram; Palasantzas, G.; Kooi, B. J.; De Hosson, J. Th. M.

    2007-01-01

    The relationship between retention loss in single crystal PbTiO3 ferroelectric thin films and leakage currents is demonstrated by piezoresponse and conductive atomic force microscopy measurements. It was found that the polarization reversal in the absence of an electric field followed a stretched

  9. Quantitative Analysis Method of Output Loss due to Restriction for Grid-connected PV Systems

    Science.gov (United States)

    Ueda, Yuzuru; Oozeki, Takashi; Kurokawa, Kosuke; Itou, Takamitsu; Kitamura, Kiyoyuki; Miyamoto, Yusuke; Yokota, Masaharu; Sugihara, Hiroyuki

    Voltage of power distribution line will be increased due to reverse power flow from grid-connected PV systems. In the case of high density grid connection, amount of voltage increasing will be higher than the stand-alone grid connection system. To prevent the over voltage of power distribution line, PV system's output will be restricted if the voltage of power distribution line is close to the upper limit of the control range. Because of this interaction, amount of output loss will be larger in high density case. This research developed a quantitative analysis method for PV systems output and losses to clarify the behavior of grid connected PV systems. All the measured data are classified into the loss factors using 1 minute average of 1 second data instead of typical 1 hour average. Operation point on the I-V curve is estimated to quantify the loss due to the output restriction using module temperature, array output voltage, array output current and solar irradiance. As a result, loss due to output restriction is successfully quantified and behavior of output restriction is clarified.

  10. Power quality. Analysis of the losses related to the tension and current distortion in the electric network; Calidad de la energia electrica. Analisis de las perdidas relacionadas con la distorsion de la tension y corriente de la red electrica

    Energy Technology Data Exchange (ETDEWEB)

    Rauch Sitar, Vladimir [Universidad Autonoma de Queretaro, Facultad de Ingenieria, Queretaro (Mexico)

    1994-12-31

    In recent times every day one speaks more about power quality and about the losses produced by the tension and current distortion. The distortion in the electric network and the consumption tend to keep on increasing, and each day there will be the need of applying more resources to handle it inside a reasonable range. In this article the situation of the power quality is analyzed in the most general case and also simplified for special cases. On base on the distortion coefficients of tension and current a matrix is created where the harmonics coefficients of tension as well as the current appear in an organized form an all of the elements of that matrix are analyzed. Some topological rules are created in order to give the simplest orientation in the complex situation. The article is useful to supervise the power quality in all of the typical cases and establish a base for a more detailed analysis. [Espanol] En los ultimos tiempos cada dia mas se esta hablando sobre la calidad de la energia electrica (Power Quality) y sobre las perdidas provocadas con este factor. La distorsion de la red electrica y del consumo tiene la tendencia de seguir aumentando y cada dia mas habra que dedicar mas recursos para manejarla dentro de un rango razonable. En el articulo presentado se analiza la situacion de la calidad de energia en caso mas general y tambien simplificada para los casos especiales. A base de coeficientes de distorsion, de tension y corriente se crea una Matriz donde figuran tanto los coeficientes de armonicas de tension como de corriente en una forma ordenada y se analizan todos los elementos de esta matriz. Se crean algunas reglas topologicas para dar la orientacion mas simple en la situacion compleja. El articulo sirve para dar supervision a la calidad de energia en todos los casos tipicos y establecer una base para el analisis mas detallado.

  11. Model for the probability of core uncovery in loss of offsite power induced accidents, as applied in the Probabilistic Safety Study for ENEL PWR standard power plant

    International Nuclear Information System (INIS)

    Silvestri, E.; Serra, S.; Paddleford, D.F.

    1985-01-01

    This paper discusses one particular aspect of the Probabilistic Safety Study conducted for the Italian reference PWR or Progetto Unificato Nucleare (PUN) design. The event scenario addressed involves the loss of offsite power (LOOSP) initiating event in conjunction with an independent loss of certain support systems (to the exclusion of the total independent loss of on-site power which is treated similarly in a separate event tree). An event tree is developed to address the potential for a consequential small LOCA due to reactor coolant pump (RCP) seal failure under conditions of inadequate seal cooling and the subsequent potential for core uncovery should emergency systems be unavailable and not recovered in adequate time. The event scenario and the quantification methodology used are described. Results and sensitivities are presented

  12. High temperature superconductor current leads

    International Nuclear Information System (INIS)

    Zeimetz, B.; Liu, H.K.; Dou, S.X.

    1996-01-01

    Full text: The use of superconductors in high electrical current applications (magnets, transformers, generators etc.) usually requires cooling with liquid Helium, which is very expensive. The superconductor itself produces no heat, and the design of Helium dewars is very advanced. Therefore most of the heat loss, i.e. Helium consumption, comes from the current lead which connects the superconductor with its power source at room temperature. The current lead usually consists of a pair of thick copper wires. The discovery of the High Temperature Superconductors makes it possible to replace a part of the copper with superconducting material. This drastically reduces the heat losses because a) the superconductor generates no resistive heat and b) it is a very poor thermal conductor compared with the copper. In this work silver-sheathed superconducting tapes are used as current lead components. The work comprises both the production of the tapes and the overall design of the leads, in order to a) maximize the current capacity ('critical current') of the superconductor, b) minimize the thermal conductivity of the silver clad, and c) optimize the cooling conditions

  13. Research on Single-Phase PWM Converter with Reverse Conducting IGBT Based on Loss Threshold Desaturation Control

    Directory of Open Access Journals (Sweden)

    Xianjin Huang

    2017-11-01

    Full Text Available In the application of vehicle power supply and distributed power generation, there are strict requirements for the pulse width modulation (PWM converter regarding power density and reliability. When compared with the conventional insulated gate bipolar transistor (IGBT module, the Reverse Conducting-Insulated Gate Bipolar Transistor (RC-IGBT with the same package has a lower thermal resistance and higher current tolerance. By applying the gate desaturation control, the reverse recovery loss of the RC-IGBT diode may be reduced. In this paper, a loss threshold desaturation control method is studied to improve the output characteristics of the single-phase PWM converter with a low switching frequency. The gate desaturation control characteristics of the RC-IGBT’s diode are studied. A proper current limit is set to avoid the ineffective infliction of the desaturation pulse, while the bridge arm current crosses zero. The expectation of optimized loss decrease is obtained, and the better performance for the RC-IGBTs of the single-phase PWM converter is achieved through the optimized desaturation pulse distribution. Finally, the improved predictive current control algorithm that is applied to the PWM converter with RC-IGBTs is simulated, and is operated and tested on the scaled reduced power platform. The results prove that the gate desaturation control with the improved predictive current algorithm may effectively improve the RC-IGBT’s characteristics, and realize the stable output of the PWM converter.

  14. Power deposition profile during lower hybrid current drive in Tore Supra

    International Nuclear Information System (INIS)

    Pecquet, A.L.; Moreau, D.; Fall, T.; Lasalle, J.; Lecoustey, P.; Mattioli, M.; Peysson, Y.; Auge, N.; Rodriguez, L.; Talvard, M.; Hubbard, A.; Moret, J.M.

    1991-01-01

    Lower hybrid current drive (LHCD) experiments have been performed in Tore Supra in various density regimes. The total power coupled to the plasma reached 4MW and a strong electron heating has been observed. To investigate the power deposition mechanism on the electrons, r.f power modulation experiments have been performed. These experiments allow us to estimate the power deposition profiles on both thermal and non-thermal electrons and also to study their respective time responses. From these studies it is possible to deduce a thermal heating scenario which agrees with the experimental results

  15. A micro-power LDO with piecewise voltage foldback current limit protection

    International Nuclear Information System (INIS)

    Wei Hailong; Liu Youbao; Guo Zhongjie; Liao Xue

    2012-01-01

    To achieve a constant current limit, low power consumption and high driving capability, a micro-power LDO with a piecewise voltage-foldback current-limit circuit is presented. The current-limit threshold is dynamically adjusted to achieve a maximum driving capability and lower quiescent current of only 300 nA. To increase the loop stability of the proposed LDO, a high impedance transconductance buffer under a micro quiescent current is designed for splitting the pole that exists at the gate of the pass transistor to the dominant pole, and a zero is designed for the purpose of the second pole phase compensation. The proposed LDO is fabricated in a BiCMOS process. The measurement results show that the short-circuit current of the LDO is 190 mA, the constant limit current under a high drop-out voltage is 440 mA, and the maximum load current under a low drop-out voltage is up to 800 mA. In addition, the quiescent current of the LDO is only 7 μA, the load regulation is about 0.56% on full scale, the line regulation is about 0.012%/V, the PSRR at 120 Hz is 58 dB and the drop-out voltage is only 70 mV when the load current is 250 mA. (semiconductor integrated circuits)

  16. Model Predictive Control of a Wave Energy Converter with Discrete Fluid Power Power Take-Off System

    DEFF Research Database (Denmark)

    Hansen, Anders Hedegaard; Asmussen, Magnus Færing; Bech, Michael Møller

    2018-01-01

    Wave power extraction algorithms for wave energy converters are normally designed without taking system losses into account leading to suboptimal power extraction. In the current work, a model predictive power extraction algorithm is designed for a discretized power take of system. It is shown how...... the quantized nature of a discrete fluid power system may be included in a new model predictive control algorithm leading to a significant increase in the harvested power. A detailed investigation of the influence of the prediction horizon and the time step is reported. Furthermore, it is shown how...

  17. Allocation of losses in distribution system with dispersed generation of electricity

    International Nuclear Information System (INIS)

    Atanasovski, Metodija B.

    2005-01-01

    obtained with the new method are compared with the appropriate results calculated with the other methods from the literature. Results of power flow solution are used as input data for allocation of losses. Power flow calculations are performed using Newton-Raphson method and current summation method. Calculations are performed using the typical daily load curves in each node of the network. Two typical cases are considered: winter working day and summer Sunday. Conclusions are presented at the end of the work. (Author)

  18. Current Trends in the Nuclear Power Global Market

    Directory of Open Access Journals (Sweden)

    Mariya Mikhailovna Osetskaya

    2018-03-01

    Full Text Available The review of the nuclear energy technologies market, namely the main processes of the initial and final stages of the nuclear fuel cycle (NTC was shown. The authors reveal key players in the markets of natural uranium mining, conversion, enrichment, fabrication of nuclear fuel, direct disposal, and reprocessing as well as determine their market shares. The article shows the fundamental factors influencing the development trends of the global nuclear power market such as: units’ commissioning in China, India, the Republic of Korea and other countries, the restart of the Japanese nuclear power plants, growth of uranium supplies long-term contracting planned for the period up to 2025, volatility of world prices of the NFC initial and final stages, political, economic and environmental reasons for the nuclear power generation choice. The article presents the results of analyses of Russian and world prices on the NFC initial and final stages main processes’ allowing to draw a conclusion about the current competitiveness of Russian nuclear energy technologies

  19. Power Swing Detection in UPFC-Compensated Line by Phase Angle of Current

    DEFF Research Database (Denmark)

    Khodaparast, Jalal; Khederzadeh, M.; Silva, Filipe Miguel Faria da

    2017-01-01

    Power swing blocker (PSB) is a complementary part of distance relay protection, that detects power swing, in order to prevent unintended operation of a distance relay. Unified power flow controller (UPFC) is used in power system to control both active and reactive powers and its operation during...... condition. The results show that these indices may no longer work in systems with UPFC. In addition, this paper proposes a new method for detecting power swing based on the phase angle of current at relay point and compares it with two other methods. The new method distinguishes power swing from a fault...

  20. Improving the reliability of Class 1E power distribution to instrumentation and control cabinets on nuclear power plants in the USA. Final report

    International Nuclear Information System (INIS)

    Brennen, M.B.

    1995-09-01

    This study was conducted to explore nontraditional electric power distribution concepts to improve the reliability of uninterruptible power to vital Instrumentation and Control (I and C) cabinets in future US nuclear power plants. The study incorporated comparative technical and economic evaluations of existing and nontraditional uninterruptible power supply (UPS) concepts. All nontraditional distribution concepts were based on available or already emerging components or semiconductor devices. Another purpose of the study was to reduce the cost and complexity of present power distribution and to lower maintenance, replacement, degradation and fault location requirements. The possible reduction of distribution losses, especially during operation under battery power, was also evaluated. The study indicates that direct current distribution at 48 or 125 Vdc levels would have more than an order of magnitude improvement over the reliability of present alternating current supplies at comparable cost. Furthermore, losses under battery power could be reduced significantly with respect to present distribution losses. An inherent advantage of DC distribution is that power transfer from the failed power bus to an operational bus occurs naturally and instantaneously via two simple and reliable semiconductor diodes. AC distribution, on the other hand, requires complex synchronization, decision making and gated semiconductor switching devices for power bus transfer all of which could be eliminated. Some of the concepts presented may also be applied to make existing vital (Class 1E) uninterruptible power supplies in US nuclear plants more reliable

  1. Switching current imbalance mitigation in power modules with parallel connected SiC MOSFETs

    DEFF Research Database (Denmark)

    Beczkowski, Szymon; Jørgensen, Asger Bjørn; Li, Helong

    2017-01-01

    Multichip power modules use parallel connected chips to achieve high current rating. Due to a finite flexibility in a DBC layout, some electrical asymmetries will occur in the module. Parallel connected transistors will exhibit uneven static and dynamic current sharing due to these asymmetries....... Especially important are the couplings between gate and power loops of individual transistors. Fast changing source currents cause gate voltage imbalances yielding uneven switching currents. Equalizing gate voltages seen by paralleled transistors, done by adjusting source bond wires, is proposed...... in this paper. Analysis is performed on an industry standard DBC layout using numerically extracted module parasitics. The method of tuning individual source inductances shows clear improvement in dynamic current balancing and prevents excessive current overshoot during transistors turn-on....

  2. Development of high-power inverter supply for current drive of FRC plasma

    International Nuclear Information System (INIS)

    Kitano, Katsuhisa; Higashikozono, Takamitsu; Okada, Shigefumi; Goto, Seiichi

    2003-01-01

    High-Power RF supply is developed for the current drive of FRC (Field Reversed Configuration) plasma. The rotating magnetic field is produced by the four antennas set in the parallel direction to the geometrical axis of the FRC and faced each other. The sinusoidal currents with shifted phases by 90 degree each other should be supplied to the antennas. The two power supplies are necessary if a pair of the antennas faced oppositely are connected. Considering the plasma parameters, the rotating field of 50-100kHz and 50G at the center axis is expected to be required. We develop the adequate RF power supply for the purpose. The power supply consists of the inverter circuit, the step-up transformer and the LC tank ciruit. For the switching device of the inverter circuit, the IGBT (Insulated Gate Bipolar Transistor) is adopted. The inverter circuit is full bridge type. To operate it at high voltages, its arm consists of the 3 IGBTs arranged series. The output of the inverter is connected to the tank circuit by way of the step-up transformer with air core. The tank circuit is the parallel circuit of the antenna and the capacitor. By the adjustment of the frequency of the inverter output to the resonance frequency of the tank circuit, the large sinusoidal waveform current is obtained. The developed power supply can produce the current of 5kA at 10kV to the dummy antenna with almost the same inductance of the antenna. (author)

  3. IGBT Dynamic Loss Reduction through Device Level Soft Switching

    Directory of Open Access Journals (Sweden)

    Lan Ma

    2018-05-01

    Full Text Available Due to its low conduction loss, hence high current ratings, as well as low cost, Silicon Insulated Gate Bipolar Transistor (Si IGBT is widely used in high power applications. However, its switching frequency is generally low because of relatively large switching losses. Silicon carbide Metal-Oxide-Semiconductor Field-Effect Transistor (SiC MOSFET is much more superior due to their fast switching speed, which is determined by the internal parasitic capacitance instead of the stored charges, like the IGBT. By the combination of SiC MOSFET and Si IGBT, this paper presents a novel series hybrid switching method to achieve IGBT’s dynamic switching loss reduction by switching under Zero Voltage Hard Current (ZVHC turn-on and Zero Current Hard Voltage (ZCHV turn-off conditions. Both simulation and experimental results of IGBT are carried out, which shows that the soft switching of IGBT has been achieved both in turn-on and turn-off period. Thus 90% turn-on loss and 57% turn-off loss are reduced. Two different IGBTs’ test results are also provided to study the modulation parameter’s effect on the turn-off switching loss. Furthermore, with the consideration of voltage and current transient states, a new soft switching classification is proposed. At last, another improved modulation and Highly Efficient and Reliable Inverter Concept (HERIC inverter are given to validate the effectiveness of the device level hybrid soft switching method application.

  4. Current scaling of radiated power for 40-mm diameter single wire arrays on Z

    Science.gov (United States)

    Nash, T. J.; Cuneo, M. E.; Spielman, R. B.; Chandler, G. A.; Leeper, R. J.; Seaman, J. F.; McGurn, J.; Lazier, S.; Torres, J.; Jobe, D.; Gilliland, T.; Nielsen, D.; Hawn, R.; Bailey, J. E.; Lake, P.; Carlson, A. L.; Seamen, H.; Moore, T.; Smelser, R.; Pyle, J.; Wagoner, T. C.; LePell, P. D.; Deeney, C.; Douglas, M. R.; McDaniel, D.; Struve, K.; Mazarakis, M.; Stygar, W. A.

    2004-11-01

    In order to estimate the radiated power that can be expected from the next-generation Z-pinch driver such as ZR at 28 MA, current-scaling experiments have been conducted on the 20 MA driver Z. We report on the current scaling of single 40 mm diameter tungsten 240 wire arrays with a fixed 110 ns implosion time. The wire diameter is decreased in proportion to the load current. Reducing the charge voltage on the Marx banks reduces the load current. On one shot, firing only three of the four levels of the Z machine further reduced the load current. The radiated energy scaled as the current squared as expected but the radiated power scaled as the current to the 3.52±0.42 power due to increased x-ray pulse width at lower current. As the current is reduced, the rise time of the x-ray pulse increases and at the lowest current value of 10.4 MA, a shoulder appears on the leading edge of the x-ray pulse. In order to determine the nature of the plasma producing the leading edge of the x-ray pulse at low currents further shots were taken with an on-axis aperture to view on-axis precursor plasma. This aperture appeared to perturb the pinch in a favorable manner such that with the aperture in place there was no leading edge to the x-ray pulses at lower currents and the radiated power scaled as the current squared ±0.75. For a full-current shot we will present x-ray images that show precursor plasma emitting on-axis 77 ns before the main x-ray burst.

  5. Economic Loan Loss Provision and Expected Loss

    Directory of Open Access Journals (Sweden)

    Stefan Hlawatsch

    2010-10-01

    Full Text Available The intention of a loan loss provision is the anticipation of the loan's expected losses by adjusting the book value of the loan. Furthermore, this loan loss provision has to be compared to the expected loss according to Basel II and, in the case of a difference, liable equity has to be adjusted. This however assumes that the loan loss provision and the expected loss are based on a similar economic rationale, which is only valid conditionally in current loan loss provisioning methods according to IFRS. Therefore, differences between loan loss provisions and expected losses should only result from different approaches regarding the parameter estimation within each model and not due to different assumptions regarding the outcome of the model. The provisioning and accounting model developed in this paper overcomes the before-mentioned shortcomings and is consistent with an economic rationale of expected losses. Additionally, this model is based on a close-to-market valuation of the loan that is in favor of the basic idea of IFRS. Suggestions for changes in current accounting and capital requirement rules are provided.

  6. A Short-Current Control Method for Constant Frequency Current-Fed Wireless Power Transfer Systems

    Directory of Open Access Journals (Sweden)

    Yanling Li

    2017-04-01

    Full Text Available Frequency drift is a serious problem in Current-Fed Wireless Power Transfer (WPT systems. When the operating frequency is drifting from the inherent Zero Voltage Switching (ZVS frequency of resonant network, large short currents will appear and damage the switches. In this paper, an inductance-dampening method is proposed to inhibit short currents and achieve constant-frequency operation. By adding a small auxiliary series inductance in the primary resonant network, short currents are greatly attenuated to a safe level. The operation principle and steady-state analysis of the system are provided. An overlapping time self-regulating circuit is designed to guarantee ZVS running. The range of auxiliary inductances is discussed and its critical value is calculated exactly. The design methodology is described and a design example is presented. Finally, a prototype is built and the experimental results verify the proposed method.

  7. A hybrid superconducting fault current limiter for enhancing transient stability in Korean power systems

    Science.gov (United States)

    Seo, Sangsoo; Kim, Seog-Joo; Moon, Young-Hwan; Lee, Byongjun

    2013-11-01

    Additional power generation sites have been limited in Korea, despite the fact load demands are gradually increasing. In order to meet these increasing demands, Korea’s power system company has begun constructing new generators at existing sites. Thus, multi-unit plants can create problems in terms of transient stability when a large disturbance occurs. This paper proposes a hybrid superconducting fault current limiter (SFCL) application to enhance the transient stability of multi-unit power plants. SFCLs reduce fault currents, and limitation currents decrease the imbalance of the mechanical and electrical torque of the generators, resulting in an improvement in transient stability.

  8. Enhancing the Frequency Adaptability of Periodic Current Controllers for Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2015-01-01

    It is mandatory for grid-connected power converters to synchronize the feed-in currents with the grid. Moreover, the power converters should produce feed-in currents with low total harmonic distortions according to the demands, by employing advanced current controllers, e.g., Proportional Resonant...... deviations. Experiments on a single-phase grid-connected inverter system are presented, which have verified the proposals and also the effectiveness of the frequency adaptive current controllers....... (PR) and Repetitive Controllers (RC). The synchronization is actually to detect the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is commonly performed by a Phase-Locked-Loop (PLL) system. As a consequence, harmonics and deviations...

  9. A subleading power operator basis for the scalar quark current

    Science.gov (United States)

    Chang, Cyuan-Han; Stewart, Iain W.; Vita, Gherardo

    2018-04-01

    Factorization theorems play a crucial role in our understanding of the strong interaction. For collider processes they are typically formulated at leading power and much less is known about power corrections in the λ ≪ 1 expansion. Here we present a complete basis of power suppressed operators for a scalar quark current at O({λ}^2) in the amplitude level power expansion in the Soft Collinear Effective Theory, demonstrating that helicity selection rules significantly simplify the construction. This basis applies for the production of any color singlet scalar in q\\overline{q} annihilation (such as b\\overline{b}\\to H ). We also classify all operators which contribute to the cross section at O({λ}^2) and perform matching calculations to determine their tree level Wilson coefficients. These results can be exploited to study power corrections in both resummed and fixed order perturbation theory, and for analyzing the factorization properties of gauge theory amplitudes and cross sections at subleading power.

  10. Electronic Power Transformer for Power Distribution Networks

    Directory of Open Access Journals (Sweden)

    Ermuraсhi Iu.V.

    2017-12-01

    Full Text Available Reducing losses in electricity distribution networks is a current technical problem. This issue also has social and environmental aspects. As a promising solution one can examine the direct distribution from the medium voltage power network using new equipment based on the use of power electronics. The aim of the paper is to propose and argue an innovative technical solution for the realization of the Solid State Transformer (SST in order to decrease the number of energy transformation stages compared to the known solutions, simplifying the topology of the functional scheme with the reduction of production costs and the loss of energy in transformers used in electrical distribution networks. It is proposed the solution of simplifying the topology of the AC/AC electronic transformer by reducing the number of passive electronic components (resistors, inductors, capacitors and active (transistors. The inverter of the SST transformer ensures the switching mode of the transistors, using for this purpose the inductance of the magnetic leakage flux of the high frequency transformer. The robustness of the laboratory sample of the SST 10 / 0.22 kV transformer with the power of 20 kW was manufactured and tested. Testing of the laboratory sample confirmed the functionality of the proposed scheme and the possibility of switching of the transistors to at zero current (ZCS mode with the reduction of the energy losses. In the proposed converter a single high-frequency transformer with a simplified construction with two windings is used, which reduces its mass and the cost of making the transformer. The reduction in the manufacturing cost of the converter is also due to the decrease in the number of links between the functional elements.

  11. Power Quality Problems Due to Transformer Inrush Current

    OpenAIRE

    Tokić, A.; Uglešić, I.

    2017-01-01

    Transformer energization can produce a large nonsinuoidal inrush current which contains both odd and higher order harmonic components that can put transformer winding under mechanical stress. Additionally, they can cause irregular tripping of harmonic protection relays. Furthermore, in relatively weak power systems, such as is the Bosnian system, the superposition of harmonic components with system resonance frequencies may produce temporary overvoltages (TOV). Transformer wind...

  12. A current-controlled PWM bipolar power supply for a magnet load

    International Nuclear Information System (INIS)

    Kang, Y.G.; McGhee, D.G.

    1994-01-01

    The Advanced Photon Source, at Argonne National Laboratory will produce the world's brightest x-ray beams when it is complete. A number of correction magnets are used to maintain proper beam position. Basically, two different types of bipolar power supplies are used for all the correction magnets: one requires dc correction only, and the other requires dc and ac correction. Normally linear-mode power amplifiers would be used for the bipolar power supplies. However, linear-mode power amplifiers dissipate a substantial amount of power as heat, resulting in poor efficiency for their large size. In addition, most commercial bipolar power supplies are linear-mode and available for lower power levels. Therefore, for higher power levels it was necessary to design a bipolar power supply that uses switch-mode power conversion. This paper describes a control technique for a pulse-width-modulatcd bipolar power supply, which can deliver a controlled current, dc plus ac to a correction magnet. A design example of a 150A bipolar power supply is presented

  13. DISTRIBUTION NETWORK RECONFIGURATION FOR POWER LOSS MINIMIZATION AND VOLTAGE PROFILE ENHANCEMENT USING ANT LION ALGORITHM

    Directory of Open Access Journals (Sweden)

    Maryam Shokouhi

    2017-06-01

    Full Text Available Distribution networks are designed as a ring and operated as a radial form. Therefore, the reconfiguration is a simple and cost-effective way to use existing facilities without the need for any new equipment in distribution networks to achieve various objectives such as: power loss reduction, feeder overload reduction, load balancing, voltage profile improvement, reducing the number of switching considering constraints that ultimately result in the power loss reduction. In this paper, a new method based on the Ant Lion algorithm (a modern meta-heuristic algorithm is provided for the reconfiguration of distribution networks. Considering the extension of the distribution networks and complexity of their communications networks, and the various parameters, using smart techniques is inevitable. The proposed approach is tested on the IEEE 33 & 69-bus radial standard distribution networks. The Evaluation of results in MATLAB software shows the effectiveness of the Ant Lion algorithm in the distribution network reconfiguration.

  14. Recent DIII-D high power heating and current drive experiments

    International Nuclear Information System (INIS)

    Simonen, T.C.; Jackson, G.L.; Mahdavi, M.A.; Petrie, T.W.; Politzer, P.A.; Taylor, T.S.; Lazarus, E.A.

    1994-02-01

    This paper describes recent DIII-D high power heating and current drive experiments. Describes are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal beta

  15. Hysteresis losses in MgB{sub 2} superconductors exposed to combinations of low AC and high DC magnetic fields and transport currents

    Energy Technology Data Exchange (ETDEWEB)

    Magnusson, N., E-mail: niklas.magnusson@sintef.no [SINTEF Energy Research, NO-7465 Trondheim (Norway); Abrahamsen, A.B. [DTU Wind Energy, Technical University of Denmark, DK-4000 Roskilde (Denmark); Liu, D. [Electrical Power Processing Group, TU Delft, Mekelweg 4, NL-2628 CD Delft (Netherlands); Runde, M. [SINTEF Energy Research, NO-7465 Trondheim (Norway); Polinder, H. [Electrical Power Processing Group, TU Delft, Mekelweg 4, NL-2628 CD Delft (Netherlands)

    2014-11-15

    Highlights: • A method for calculating hysteresis losses in the low AC – high DC magnetic field and transport current range has been shown. • The method can be used in the design of wind turbine generators for calculating the losses in the generator DC rotor. • First estimates indicate tolerable current ripple in the 0.1% range for a 4 T DC MgB{sub 2} generator rotor coil. - Abstract: MgB{sub 2} superconductors are considered for generator field coils for direct drive wind turbine generators. In such coils, the losses generated by AC magnetic fields may generate excessive local heating and add to the thermal load, which must be removed by the cooling system. These losses must be evaluated in the design of the generator to ensure a sufficient overall efficiency. A major loss component is the hysteresis losses in the superconductor itself. In the high DC – low AC current and magnetic field region experimental results still lack for MgB{sub 2} conductors. In this article we reason towards a simplified theoretical treatment of the hysteresis losses based on available models in the literature with the aim of setting the basis for estimation of the allowable magnetic fields and current ripples in superconducting generator coils intended for large wind turbine direct drive generators. The resulting equations use the DC in-field critical current, the geometry of the superconductor and the magnitude of the AC magnetic field component as parameters. This simplified approach can be valuable in the design of MgB{sub 2} DC coils in the 1–4 T range with low AC magnetic field and current ripples.

  16. Regional power marketing opportunities : current challenges and future outlooks

    International Nuclear Information System (INIS)

    Stiers, M.

    1998-01-01

    The North American demand for electric power and natural gas by sector was described and a comparison was made between the number of FERC certified electric power marketers versus natural gas marketing companies between 1986 and 1997 to illustrate the extent of changes that occurred during the decade. Regional opportunities for energy marketers were reviewed. By way of current challenges, the author identified (1) regulatory impediments, (2) divestiture of assets, (3) creation of an effective ISO, (4) establishment of effective pricing mechanisms, (5) customer systems and infrastructure, (6) forcing legislative reform, and (7) stranded cost recovery, as the most important. figs

  17. Extrapolating power-ramp performance criteria for current and advanced CANDU fuels

    Energy Technology Data Exchange (ETDEWEB)

    Tayal, M.; Chassie, G.G

    2000-06-01

    To improve the precision and accuracy of power-ramp performance criteria for high-burnup fuel, we have examined in-reactor fuel performance data as well as out-reactor test data. The data are consistent with some of the concepts used in the current formulations for defining fuel failure thresholds, such as size of power-ramp and extent of burnup. Our review indicates that there is a need to modify some other aspects of the current formulations; therefore, a modified formulation is presented in this paper. The improvements mainly concern corrodent concentration and its relationships with threshold stress for failure. The new formulation is consistent with known and expected trends such as strength of Zircaloy in corrosive environment, timing of the release of fission products to the pellet-to-sheath gap, CANLUB coating, and fuel burnup. Because of the increased precision and accuracy, the new formulation is better able to identify operational regimes that are at risk of power-ramp failures; this predictive ability provides enhanced protection to fuel against power-ramp defects. At die same time, by removing unnecessary conservatisms in other areas, the new formulation permits a greater range of defect-free operational envelope as well as larger operating margins in regions that are, in fact, not prone to power-ramp failures. (author)

  18. Recent DIII-D high power heating and current drive experiments

    International Nuclear Information System (INIS)

    Simonen, T.C.; Jackson, G.L.; Lazarus, E.A.; Mahdavi, M.A.; Petrie, T.W.; Politzer, P.A.; Taylor, T.S.

    1995-01-01

    This paper describes recent DIII-D high power heating and current drive experiments. Described are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal β. ((orig.))

  19. Recent DIII-D high power heating and current drive experiments

    Energy Technology Data Exchange (ETDEWEB)

    Simonen, T.C. [General Atomics, San Diego, CA (United States); Jackson, G.L. [General Atomics, San Diego, CA (United States); Lazarus, E.A. [Oak Ridge National Lab., TN (United States); Mahdavi, M.A. [General Atomics, San Diego, CA (United States); Petrie, T.W. [General Atomics, San Diego, CA (United States); Politzer, P.A. [General Atomics, San Diego, CA (United States); Taylor, T.S. [General Atomics, San Diego, CA (United States); DIII-D Team

    1995-01-01

    This paper describes recent DIII-D high power heating and current drive experiments. Described are experiments with improved wall conditioning, divertor particle pumping, radiative divertor experiments, studies of plasma shape and high poloidal {beta}. ((orig.)).

  20. Development of Abnormal Operating Strategies for Loss of Ultimate Heat Sink (LOUHS) at Shutdown Mode in Westinghouse Type Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Duk-Joo; Lee, Seung-Chan; Sung, Je-Joong; Ha, Sang Jun [KHNP CRI, Daejeon (Korea, Republic of); Hwang, Su-Hyun [FNC Tech. Co., Yongin (Korea, Republic of)

    2016-10-15

    Loss of all AC power is classified as one of multiple failure accident by regulatory guide of Korean accident management program. Therefore we need develop strategies for the abnormal operating procedure both of power operating and shutdown mode. This paper developed abnormal operating guideline for loss of all AC power by analysis of accident scenario in pressurized water reactor. This paper analyzed the extended SBO in shutdown operating mode and developed the operating strategy of the abnormal operation procedure. Operator action for the emergency are not required to take in 500 minutes and 60 minutes in intact and opened RCS state respectively.

  1. Power and momentum relations in rotating magnetic field current drive

    Energy Technology Data Exchange (ETDEWEB)

    Hugrass, W N [Flinders Univ. of South Australia, Bedford Park. School of Physical Sciences

    1984-01-01

    The use of rotating magnetic fields (RMF) to drive steady currents in plasmas involves a transfer of energy and angular momentum from the radio frequency source feeding the rotating field coils to the plasma. The power-torque relationships in RMF systems are discussed and the analogy between RMF current drive and the polyphase induction motor is explained. The general relationship between the energy and angular momentum transfer is utilized to calculate the efficiency of the RMF plasma current drive. It is found that relatively high efficiencies can be achieved in RMF current drive because of the low phase velocity and small slip between the rotating field and the electron fluid.

  2. Study of specific loss power of magnetic fluids with various viscosities

    Energy Technology Data Exchange (ETDEWEB)

    Phong, P.T., E-mail: phamthanhphong@tdt.edu.vn [Department for Management of Science and Technology Development, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Faculty of Applied Sciences, Ton Duc Thang University, Ho Chi Minh City (Viet Nam); Nguyen, L.H., E-mail: luuhuunguyen@ukh.edu.vn [Institute of Materials Science, Vietnam Academy of Science and Technology,18- Hoang Quoc Viet Street, Cau Giay District, Ha Noi City (Viet Nam); Khanh Hoa University, 1- Nguyen Chanh Street, Nha Trang City, Khanh Hoa Province (Viet Nam); Phong, L.T.H., E-mail: lthp52a@gmail.com [Institute of Materials Science, Vietnam Academy of Science and Technology,18- Hoang Quoc Viet Street, Cau Giay District, Ha Noi City (Viet Nam); Nam, P.H., E-mail: namph.ims@gmail.com [Institute of Materials Science, Vietnam Academy of Science and Technology,18- Hoang Quoc Viet Street, Cau Giay District, Ha Noi City (Viet Nam); Manh, D.H., E-mail: manhdh.ims@gmail.com [Institute of Materials Science, Vietnam Academy of Science and Technology,18- Hoang Quoc Viet Street, Cau Giay District, Ha Noi City (Viet Nam); Lee, I.J., E-mail: lij@dongguk.ac.kr [Department of Advanced Materials Chemistry, Dongguk University-Gyeongju, Dongdae-roDongdae-ro 123, Gyeongju-Si, Gyeongbuk 38066 (Korea, Republic of); Phuc, N.X., E-mail: phucnx1949@gmail.com [Institute of Materials Science, Vietnam Academy of Science and Technology,18- Hoang Quoc Viet Street, Cau Giay District, Ha Noi City (Viet Nam)

    2017-04-15

    Abstracts: Using hydrothermal method, CoFe{sub 2}O{sub 4} (hard ferrite) and MnFe{sub 2}O{sub 4} (soft ferrite) nanoparticles of size up to 20 nm were synthesized and the viscosities were controlled using various concentrations of agar. The hydrodynamic diameter of these particles was measured and fitted to a lognormal distribution and the results showed their polydispersity is very narrow. From the calorimetric measurements of the particles stabilized in agar solutions, we have demonstrated that at a given frequency, the dependence of the specific loss power of magnetic fluids on the viscosity is in good agreement with the theoretical predictions made in the earlier studies. - Highlights: • CoFe{sub 2}O{sub 4} (hard ferrite) and MnFe{sub 2}O{sub 4} (soft ferrite) nanoparticles size up to 20 nm were synthesized. • The relaxation loss depends on both the particle's intrinsic properties and the viscosity of the environment. • The SLP of hard nanoparticles strongly decreases with increasing the viscosity whereas that of soft nanoparticles remains almost unchanged.

  3. Comprehensive Investigation on Current Imbalance among Parallel Chips inside MW-Scale IGBT Power Modules

    DEFF Research Database (Denmark)

    Wu, Rui; Smirnova, Liudmila; Wang, Huai

    2015-01-01

    With the demands for increasing the power rating and improving reliability level of the high power IGBT modules, there are further needs of understanding how to achieve stable paralleling and identical current sharing between the chips. This paper investigates the stray parameters imbalance among...... parallel chips inside the 1.7 kV/1 kA high power IGBT modules at different frequencies by Ansys Q3D parastics extractor. The resulted current imbalance is further confirmed by experimental measurement....

  4. Possible Power Estimation of Down-Regulated Offshore Wind Power Plants

    DEFF Research Database (Denmark)

    Gögmen, Tuhfe

    The penetration of offshore wind power is continuously increasing in the Northern European grids. To assure safety in the operation of the power system, wind power plants are required to provide ancillary services, including reserve power attained through down-regulating the wind farm from its...... power plant. The developed procedure, the PossPOW algorithm, can also be used in the wind farm control as it yields a real-time wind farm power curve. The modern wind turbines have a possible power signal at the turbine level and the current state of the art is to aggregate those signals to achieve...... the wind farm scale production capacity. However the summation of these individual signals is simply an over-estimation for the wind power plant, due to reduced wake losses during curtailment. The determination of the possible power with the PossPOW algorithm works as follows: firstly the second...

  5. High current transistor pulse generator

    International Nuclear Information System (INIS)

    Nesterov, V.; Cassel, R.

    1991-05-01

    A solid state pulse generator capable of delivering high current trapezoidally shaped pulses into an inductive load has been developed at SLAC. Energy stored in the capacitor bank of the pulse generator is switched to the load through a pair of Darlington transistors. A combination of diodes and Darlington transistors is used to obtain trapezoidal or triangular shaped current pulses into an inductive load and to recover the remaining energy in the same capacitor bank without reversing capacitor voltage. The transistors work in the switch mode, and the power losses are low. The rack mounted pulse generators presently used at SLAC contain a 660 microfarad storage capacitor bank and can deliver 400 amps at 800 volts into inductive loads up to 3 mH. The pulse generators are used in several different power systems, including pulse to pulse bipolar power supplies and in application with current pulses distributed into different inductive loads. The current amplitude and discharge time are controlled by the central computer system through a specially developed multichannel controller. Several years of operation with the pulse generators have proven their consistent performance and reliability. 8 figs

  6. Development of an intelligent high-voltage direct-current power supply for nuclear detectors

    International Nuclear Information System (INIS)

    Zhao Xiuliang

    1997-01-01

    The operation and performances of a new type direct-current high-voltage power supply are described. The power supply with intelligent feature is controlled by a single-chip microcomputer (8031), and various kinds of output voltage can be preset. The output-voltage is monitored and regulated by the single-chip microcomputer and displayed by LED. The output voltage is stable when the load current is within the allowable limits

  7. Design of the DC-DC power stage of the capacitor charger for MAXIDISCAP power converters

    CERN Document Server

    Cravero, Jean-Marc

    2013-01-01

    This technical report presents the design of the DC-DC power stage of the capacitor charger for MAXIDISCAP power converters. The power stage is based on a half bridge series resonant converter in Discontinuous Conduction Mode (DCM). This simple and robust topology allows obtaining a current source behavior with a low switching losses power stage. The associated control stage is implemented using a commercial controller which has differenti nternal circuits that allows a high integration of the converter control system. The report presents the design and tuning criteria for the DC-DC converter, including the power stage and the control system.

  8. Living with vision loss

    Science.gov (United States)

    Diabetes - vision loss; Retinopathy - vision loss; Low vision; Blindness - vision loss ... of visual aids. Some options include: Magnifiers High power reading glasses Devices that make it easier to ...

  9. Conceptual design of cooling anchor for current lead on HTS field coils

    Energy Technology Data Exchange (ETDEWEB)

    Hyeon, C. J.; Kim, J. H.; Quach, H. L. [Dept. of Electrical Engineering, Jeju National University, Jeju (Korea, Republic of); and others

    2017-06-15

    The role of current lead in high-temperature superconducting synchronous machine (HTSSM) is to function as a power supply by connecting the power supply unit at room temperature with the HTS field coils at cryogenic temperature. Such physical and electrical connection causes conduction and Joule-heating losses, which are major thermal losses of HTSSM rotors. To ensure definite stability and economic feasibility of HTS field coils, quickly and smoothly cooling down the current lead is a key design technology. Therefore, in this paper, we introduce a novel concept of a cooling anchor to enhance the cooling performance of a metal current lead. The technical concept of this technology is the simultaneously chilling and supporting the current lead. First, the structure of the current lead and cooling anchor were conceptually designed for field coils for a 1.5 MW-class HTSSM. Then, the effect of this installation on the thermal characteristics of HTS coils was investigated by 3D finite element analysis.

  10. Low-leakage, high-current power crowbar transformer

    International Nuclear Information System (INIS)

    Buck, R.T.; Galbraith, J.D.; Nunnally, W.C.

    1979-01-01

    The design, fabrication, and testing of two sizes of power crowbar transformers for the ZT-40 Toroidal Z-Pinch experiment at the Los Alamos Scientific Laboratory are described. Low-leakage transformers in series with the poloidal and the toroidal field coils are used to sustain magnetic field currents initially produced by 50-kV capacitor banks. The transformer primaries are driven by cost-effective, ignitron-switched, 10-kV high-density capacitor banks. The transformer secondaries, in series with the field coils, provide from 1,000 to 1,500 V to cancel the resistive voltage drop in the coil circuits. Prototype transformers, with a total leakage inductance measured in the secondary of 5 nH, have been tested with peak secondary currents in excess of 600 kA resulting from a 10-kV primary charge voltage. The test procedures and results and the mechanical construction details are presented

  11. Study of matrix converter as a current-controlled power supply in QUEST tokamak

    International Nuclear Information System (INIS)

    Liu, Xiaolong; Jiang, Yi; Nakamura, Kazuo

    2011-01-01

    Because QUEST tokamak has a divertor configuration with a higher κ and a negative n-index, a precise power supply with a rapid response is needed to control the vertical position of the plasma. A matrix converter is a direct power conversion device that uses an array of controlled bidirectional switches as the main power elements for creating a variable-output current system. This paper presents a novel three-phase to two-phase topological matrix converter as a proposed power supply that stabilizes the plasma vertical position and achieves unity input power factor. An indirect control strategy in which the matrix converter is split into a virtual rectifier stage and a virtual inverter stage is adopted. In the virtual rectifier stage, the instantaneous active power and reactive power are decoupled on the basis of system equations derived from the DQ transformation; hence, unity power factor is achieved. Space vector pulse width modulation is adopted to determine the switching time of each switch in the virtual rectifier; the output voltage of the virtual rectifier is adjusted by the virtual inverter stage to obtain the desired load current. Theoretical analyses and simulation results are provided to verify its feasibility. (author)

  12. DGA-based VAR rescheduling for transmission loss reduction

    Energy Technology Data Exchange (ETDEWEB)

    Mishra, S. [Indian Inst. of Technology, Delhi (India); Taylor, G.A. [Brunel Univ., London (United Kingdom). Brunel Inst. of Power Systems; Reddy, J.B.V. [Government of India, New Delhi (India). Dept. of Science and Technology; Naeem, M.H. [Multimedia Univ. (Malaysia). Faculty of Engineering

    2009-07-01

    Power losses in power transmission lines can be minimized by adjusting transformer taps and switchable VAR sources. Optimal power flow (OPF) is a static, nonlinear, multi-objective optimization challenge in which the optimal settings of control variables must be determined for minimizing the cost of generation, emissions, transmission losses and voltage and power flow deviations. OPF is important in power system operation because a small savings per hour can mean a large annual savings. This paper presented a method to reduce transmission power losses using a Differential Genetic Algorithm (DGA) for VAR rescheduling. The New England 39-bus power system was used as a test case. Power losses were minimized by changing the tap settings of various transformers and by varying the injected reactive power. The paper showed that certain buses in the system can improve the voltage profile and reduce transmission losses through reactive power injections from capacitor banks. In this study, minimum reactive power output of generators was maintained at zero to ensure that the generators did not draw reactive power. The DGA was shown to produce better results than the Conventional Genetic Algorithm in terms of power loss minimization. 12 refs., 1 tab., 2 figs.

  13. Power flow analysis and optimal locations of resistive type superconducting fault current limiters.

    Science.gov (United States)

    Zhang, Xiuchang; Ruiz, Harold S; Geng, Jianzhao; Shen, Boyang; Fu, Lin; Zhang, Heng; Coombs, Tim A

    2016-01-01

    Based on conventional approaches for the integration of resistive-type superconducting fault current limiters (SFCLs) on electric distribution networks, SFCL models largely rely on the insertion of a step or exponential resistance that is determined by a predefined quenching time. In this paper, we expand the scope of the aforementioned models by considering the actual behaviour of an SFCL in terms of the temperature dynamic power-law dependence between the electrical field and the current density, characteristic of high temperature superconductors. Our results are compared to the step-resistance models for the sake of discussion and clarity of the conclusions. Both SFCL models were integrated into a power system model built based on the UK power standard, to study the impact of these protection strategies on the performance of the overall electricity network. As a representative renewable energy source, a 90 MVA wind farm was considered for the simulations. Three fault conditions were simulated, and the figures for the fault current reduction predicted by both fault current limiting models have been compared in terms of multiple current measuring points and allocation strategies. Consequently, we have shown that the incorporation of the E - J characteristics and thermal properties of the superconductor at the simulation level of electric power systems, is crucial for estimations of reliability and determining the optimal locations of resistive type SFCLs in distributed power networks. Our results may help decision making by distribution network operators regarding investment and promotion of SFCL technologies, as it is possible to determine the maximum number of SFCLs necessary to protect against different fault conditions at multiple locations.

  14. Development of compact rapid charging power supply for capacitive energy storage in pulsed power drivers.

    Science.gov (United States)

    Sharma, Surender Kumar; Shyam, Anurag

    2015-02-01

    High energy capacitor bank is used for primary electrical energy storage in pulsed power drivers. The capacitors used in these pulsed power drivers have low inductance, low internal resistance, and less dc life, so it has to be charged rapidly and immediately discharged into the load. A series resonant converter based 45 kV compact power supply is designed and developed for rapid charging of the capacitor bank with constant charging current up to 150 mA. It is short circuit proof, and zero current switching technique is used to commute the semiconductor switch. A high frequency resonant inverter switching at 10 kHz makes the overall size small and reduces the switching losses. The output current of the power supply is limited by constant on-time and variable frequency switching control technique. The power supply is tested by charging the 45 kV/1.67 μF and 15 kV/356 μF capacitor banks. It has charged the capacitor bank up to rated voltage with maximum charging current of 150 mA and the average charging rate of 3.4 kJ/s. The output current of the power supply is limited by reducing the switching frequency at 5 kHz, 3.3 kHz, and 1.7 kHz and tested with 45 kV/1.67 μF capacitor bank. The protection circuit is included in the power supply for over current, under voltage, and over temperature. The design details and the experimental testing results of the power supply for resonant current, output current, and voltage traces of the power supply with capacitive, resistive, and short circuited load are presented and discussed.

  15. Large-capacity current leads

    International Nuclear Information System (INIS)

    Ballarino, A.

    2008-01-01

    Feeding superconducting magnets with reliable low-loss devices is a key issue for any cryo-electrical system. Conventional or HTS current leads can be used, and cooling methods, materials, and geometries can be chosen to optimize the thermo-electrical performance of the system. The LHC magnets are powered via more than 3000 current leads transporting altogether about 3 MA of current. With thousands of leads, the LHC lead project represents today the largest project of its kind ever undertaken. Following a review of the LHC lead project, an overview of the choices that can be made for the optimization of large capacity current leads is presented. Examples are given of other leads for large scale magnet systems for which the use of HTS is being envisaged

  16. Effect of load transients on SOFC operation—current reversal on loss of load

    Science.gov (United States)

    Gemmen, Randall S.; Johnson, Christopher D.

    The dynamics of solid oxide fuel cell (SOFC) operation have been considered previously, but mainly through the use of one-dimensional codes applied to co-flow fuel cell systems. In this paper several geometries are considered, including cross-flow, co-flow, and counter-flow. The details of the model are provided, and the model is compared with some initial experimental data. For parameters typical of SOFC operation, a variety of transient cases are investigated, including representative load increase and decrease and system shutdown. Of particular note for large load decrease conditions (e.g., shutdown) is the occurrence of reverse current over significant portions of the cell, starting from the moment of load loss up to the point where equilibrated conditions again provide positive current. Consideration is given as to when such reverse current conditions might most significantly impact the reliability of the cell.

  17. Fast ion confinement during high power tangential neutral beam injection into low plasma current discharges on the ISX-B tokamak

    International Nuclear Information System (INIS)

    Carnevali, A.; Scott, S.D.; Neilson, H.; Galloway, M.; Stevens, P.; Thomas, C.E.

    1988-01-01

    The beam ion thermalization process during tangential neutral beam injection in the ISX-B tokamak is investigated. The classical model is tested in co- and counter-injected discharges at low plasma current, a regime where large orbit width excursions enhance the importance of the loss regions. To test the model, experimental charge exchange spectra are compared with the predictions of an orbit following Monte Carlo code. Measurements of beam-plasma neutron emission and measured decay rates of the emission following beam turnoff provide additional information. Good agreement is found between theory and experiment. Furthermore, beam additivity experiments show that, globally, the confinement of beam ions remains classical, independently of the injected beam power. However, some experimental evidence suggests that the fast ion density in the plasma core did not increase with beam power in a way consistent with classical processes. (author). 35 refs, 17 figs, 3 tabs

  18. Analysis of eddy currents in the walls of the ferrite tuned RF cavity for the TRIUMF Kaon factory booster synchrotron

    International Nuclear Information System (INIS)

    Enchevich, I.B.; Barnes, M.J.; Poirier, R.L.

    1991-05-01

    In the perpendicular biased ferrite tuned cavity of the proposed TRIUMF Kaon Factory Booster Synchrotron, magnetizing flux passes through the cavity walls. If special care is not taken to minimize eddy current loss in the walls, the dissipated power would be excessive and the magnetic fields set up by the eddy currents would disturb the magnetic field being applied. By electrically isolating the cooling structure from the cavity walls and introducing slots in the walls it is possible to bring to an acceptable level both the power loss and the maximal temperatures. Based on the measurements, an analytical model - essentially 3D - was derived and the eddy currents were predicted using the circuit analysis program PSpice. The calculated surface current and power distribution agree with measurements. PSpice can now be used to determine the effect of design changes on the eddy current and power distribution. (Author) 7 refs., 5 figs

  19. Resonant converter topologies for constant-current power supplies and their applications

    International Nuclear Information System (INIS)

    Borage, Mangesh

    2013-01-01

    Power electronics, in general, and power supplies, in particular, is an important field of accelerator technology due to its widespread use, for instance in dc, ramp or pulse magnet power supplies, high voltage power supplies for electrostatic accelerators and RF amplifies, power supplies for vacuum pumps, vacuum gauges, beam diagnostic devices etc. It has been possible to meet stringent performance requirements with the continuing advancement in the field of power electronics. Resonant converters have been an active area of research in power electronics field due to variety of topologies, diverse, peculiar and useful characteristics. While the majority of the previous work on resonant converters has been directed towards developing methods of analysis and control techniques for the mentioned applications, very little has been done to explore their suitability for application as a constant-current power supply, which is either inherently required or can be advantageously applied in power supplies for various accelerator subsystems and other industrial applications such as electric arc welding, laser diode drivers, magnet illumination systems, battery charging, electrochemical processes etc.

  20. Holey fibers for low bend loss

    Science.gov (United States)

    Nakajima, Kazuhide; Saito, Kotaro; Yamada, Yusuke; Kurokawa, Kenji; Shimizu, Tomoya; Fukai, Chisato; Matsui, Takashi

    2013-12-01

    Bending-loss insensitive fiber (BIF) has proved an essential medium for constructing the current fiber to the home (FTTH) network. By contrast, the progress that has been made on holey fiber (HF) technologies provides us with novel possibilities including non-telecom applications. In this paper, we review recent progress on hole-assisted type BIF. A simple design consideration is overviewed. We then describe some of the properties of HAF including its mechanical reliability. Finally, we introduce some applications of HAF including to high power transmission. We show that HAF with a low bending loss has the potential for use in various future optical technologies as well as in the optical communication network.

  1. Optimal current waveforms for brushless permanent magnet motors

    Science.gov (United States)

    Moehle, Nicholas; Boyd, Stephen

    2015-07-01

    In this paper, we give energy-optimal current waveforms for a permanent magnet synchronous motor that result in a desired average torque. Our formulation generalises previous work by including a general back-electromotive force (EMF) wave shape, voltage and current limits, an arbitrary phase winding connection, a simple eddy current loss model, and a trade-off between power loss and torque ripple. Determining the optimal current waveforms requires solving a small convex optimisation problem. We show how to use the alternating direction method of multipliers to find the optimal current in milliseconds or hundreds of microseconds, depending on the processor used, which allows the possibility of generating optimal waveforms in real time. This allows us to adapt in real time to changes in the operating requirements or in the model, such as a change in resistance with winding temperature, or even gross changes like the failure of one winding. Suboptimal waveforms are available in tens or hundreds of microseconds, allowing for quick response after abrupt changes in the desired torque. We demonstrate our approach on a simple numerical example, in which we give the optimal waveforms for a motor with a sinusoidal back-EMF, and for a motor with a more complicated, nonsinusoidal waveform, in both the constant-torque region and constant-power region.

  2. System transient response to loss of off-site power

    International Nuclear Information System (INIS)

    Sozer, A.

    1990-01-01

    A simultaneous trip of the reactor, main circulation pumps, secondary coolant pumps, and pressurizer pump due to loss of off-site power at the High Flux Isotope Reactor (HFIR) located at the Oak Ridge National Laboratory (ORNL) has been analyzed to estimate available safety margin. A computer model based on the Modular Modeling System code has been used to calculate the transient response of the system. The reactor depressurizes from 482.7 psia down to about 23 psia in about 50 seconds and remains stable thereafter. Available safety margin has been estimated in terms of the incipient boiling heat flux ratio. It is a conservative estimate due to assumed less than available primary and secondary flows and higher than normal depressurization rate. The ratio indicates no incipient boiling conditions at the hot spot. No potential damage to the fuel is likely to occur during this transient. 2 refs., 6 figs

  3. An analytical inductor design procedure for three-phase PWM converters in power factor correction applications

    DEFF Research Database (Denmark)

    Kouchaki, Alireza; Niroumand, Farideh Javidi; Haase, Frerk

    2015-01-01

    This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyze...... to calculate the core loss in the PFC application. To investigate the impact of the dc link voltage level, two inductors for different dc voltage levels are designed and the results are compared.......This paper presents an analytical method for designing the inductor of three-phase power factor correction converters (PFCs). The complex behavior of the inductor current complicates the inductor design procedure as well as the core loss and copper loss calculations. Therefore, this paper analyzes...... circuit is used to provide the inductor current harmonic spectrum. Therefore, using the harmonic spectrum, the low and high frequency copper losses are calculated. The high frequency minor B-H loops in one switching cycle are also analyzed. Then, the loss map provided by the measurement setup is used...

  4. Mechanical Extraction of Power From Ocean Currents and Tides

    Science.gov (United States)

    Jones, Jack; Chao, Yi

    2010-01-01

    A proposed scheme for generating electric power from rivers and from ocean currents, tides, and waves is intended to offer economic and environmental advantages over prior such schemes, some of which are at various stages of implementation, others of which have not yet advanced beyond the concept stage. This scheme would be less environmentally objectionable than are prior schemes that involve the use of dams to block rivers and tidal flows. This scheme would also not entail the high maintenance costs of other proposed schemes that call for submerged electric generators and cables, which would be subject to degradation by marine growth and corrosion. A basic power-generation system according to the scheme now proposed would not include any submerged electrical equipment. The submerged portion of the system would include an all-mechanical turbine/pump unit that would superficially resemble a large land-based wind turbine (see figure). The turbine axis would turn slowly as it captured energy from the local river flow, ocean current, tidal flow, or flow from an ocean-wave device. The turbine axis would drive a pump through a gearbox to generate an enclosed flow of water, hydraulic fluid, or other suitable fluid at a relatively high pressure [typically approx.500 psi (approx.3.4 MPa)]. The pressurized fluid could be piped to an onshore or offshore facility, above the ocean surface, where it would be used to drive a turbine that, in turn, would drive an electric generator. The fluid could be recirculated between the submerged unit and the power-generation facility in a closed flow system; alternatively, if the fluid were seawater, it could be taken in from the ocean at the submerged turbine/pump unit and discharged back into the ocean from the power-generation facility. Another alternative would be to use the pressurized flow to charge an elevated reservoir or other pumped-storage facility, from whence fluid could later be released to drive a turbine/generator unit at a

  5. Current experience with nuclear power plant simulators and analysers

    International Nuclear Information System (INIS)

    Drozd, A.

    1998-01-01

    Topics of a Specialist Meeting are presented on Simulators and Plant Analyzers: Current Issues in Nuclear Power Plant Simulation (Espoo, Finland). They dealt with the need for maintaining expertise, training and education, control rooms and operator support tools, simulators as tools for plant safety analysis. The major conclusions of the payers and the meeting are discussed. (R.P.)

  6. AC losses in superconductors: a multi-scale approach for the design of high current cables

    International Nuclear Information System (INIS)

    Escamez, Guillaume

    2016-01-01

    The work reported in this PhD deals with AC losses in superconducting material for large scale applications such as cables or magnets. Numerical models involving FEM or integral methods have been developed to solve the time transient electromagnetic distributions of field and current densities with the peculiarity of the superconducting constitutive E-J equation. Two main conductors have been investigated. First, REBCO superconductors for applications operating at 77 K are studied and a new architecture of conductor (round wires) for 3 kA cables. Secondly, for very high current cables, 3-D simulations on MgB_2 wires are built and solved using FEM modeling. The following chapter introduced new development used for the calculation of AC losses in DC cables with ripples. The thesis ends with the use of the developed numerical model on a practical example in the european BEST-PATHS project: a 10 kA MgB_2 demonstrator [fr

  7. Current status of countermeasures for ageing of nuclear power plants in Japan

    International Nuclear Information System (INIS)

    Koyama, M.; Ishikawa, M.; Tajima, K.

    2002-01-01

    This paper summarizes ageing coutermeasure program of the nuclear power plants performed by the Japanese Government and industries and related activities, and describes current research program and utilization of the research results for the aged nuclear power plants. Regulatory bodies (NISA of METI: Nuclear and Industrial Safety Agency of the Ministry of Economy, Trade and Industry) reviewed the ageing issues of nuclear power plants to enhance countermeasures for the aged plants. Nuclear Power Plant Life Engineering Center (PLEC) entrusted by NISA is carrying out the task relating to the aged plants. (orig.)

  8. Design of high current bunching system and high power fast Faraday cup for high current LEBT at VECC

    International Nuclear Information System (INIS)

    Anuraag Misra, A.; Pandit, B.V.S.; Gautam Pal, C.

    2011-01-01

    A high current microwave ion source as described is currently operational at VECC. We are able to optimize 6.4 mA of proton current in the LEBT line of ion source. The cyclotron type of accelerators accept only a fraction of DC ion beam coming from ion source so a ion beam buncher is needed to increase the accepted current into the cyclotron. The buncher described in this paper is unique in its kind as it has to handle high beam loading power upto 400 W as it is designed to bunch few mA of proton beam currents at 80 keV beam energy. A sinusoidal quarter wave RF structure has been chosen to bunch the high current beam due to high Q achievable in comparison with other configurations. This buncher has been designed using CST Microwave studio 3D advanced code since the design frequency of our buncher is 42 MHz, we have provided the RF and vacuum window near the drift tube of buncher to avoid vacuum and multipacting problems and to keep maximum volume in air region. There is a provision of multipacting interlocks to shut off amplifier during multipacting. We have carried out a detailed electromagnetic and thermal design of the buncher in CST Microwave studio and simulated values of unloaded Q was calculated be 4000. We have estimated a power of 400 W to achieve gap (designed) voltage of 10 kV. This buncher is in advanced stage of fabrication. A high power fast Faraday cup is also designed to characterize the above mentioned high current bunching system. The fast Faraday cup is designed in 50 Ω coaxial geometry to transmit fast pulse of bunched ion beam. The design of Faraday cup was completed using ANSYS HFSS and a bandwidth of 1.75 GHz was achieved this faraday cup design was different from conventional Faraday cup design as we have designed the support and cooling lines at such a place on Faraday cup which do not disturb the electrical impedance of the cup. (author)

  9. Verification of the Viability of Equipotential Switching Direct Current Potential Drop Method for Piping Wall Loss Monitoring with Signal Sensitivity Analysis

    International Nuclear Information System (INIS)

    Ryu, Kyung Ha; Hwang, Il Soon; Kim, Ji Hyun

    2008-01-01

    Flow accelerated corrosion (FAC) phenomenon of low alloy carbon steels in nuclear power plant has been known as one of major degradation mechanisms. It has a potential to cause nuclear pipe rupture accident which may directly impact on the plant reliability and safety. Recently, the equipotential switching direct current potential drop (ES-DCPD) method has been developed, by the present authors, as a method to monitor wall loss in a piping. This method can rapidly monitor the thinning of piping, utilizing either the wide range monitoring (WiRM) or the narrow range monitoring (NaRM) technique. WiRM is a method to monitor wide range of straight piping, whereas NaRM focuses significantly on a narrow range such as an elbow. WiRM and NaRM can improve the reliability of the current FAC screening method that is based on computer modeling on fluid flow conditions. In this paper, the measurements by ES-DCPD are performed with signal sensitivity analyses in the laboratory environment for extended period and showed the viability of ES-DCPD for real plant applications.

  10. Self-field ac losses in biaxially aligned Y endash Ba endash Cu endash O tape conductors

    International Nuclear Information System (INIS)

    Iijima, Y.; Hosaka, M.; Sadakata, N.; Saitoh, T.; Kohno, O.; Takeda, K.

    1997-01-01

    Self-field ac losses were measured by the conventional ac four-probe method in biaxially aligned Y endash Ba endash Cu endash O tapes using polycrystalline Hastelloy tapes with textured yttria-stabilized-zirconia buffer layers. The ac losses increased in proportion to the fourth power of transport current in the high J c sample, and agreed well with Norris close-quote equation for thin strip conductors. However, the low J c sample had rather higher losses than Norris close-quote prediction, suggesting excessive magnetic flux penetration caused by percolated current paths. The results confirmed Norris close-quote prediction of the low ac losses for thin strip conductors, and indicated the importance of removing percolated structures of current paths to avoid higher ac losses than the theoretical predictions based on uniform conductors. copyright 1997 American Institute of Physics

  11. MgB2-based superconductors for fault current limiters

    Science.gov (United States)

    Sokolovsky, V.; Prikhna, T.; Meerovich, V.; Eisterer, M.; Goldacker, W.; Kozyrev, A.; Weber, H. W.; Shapovalov, A.; Sverdun, V.; Moshchil, V.

    2017-02-01

    A promising solution of the fault current problem in power systems is the application of fast-operating nonlinear superconducting fault current limiters (SFCLs) with the capability of rapidly increasing their impedance, and thus limiting high fault currents. We report the results of experiments with models of inductive (transformer type) SFCLs based on the ring-shaped bulk MgB2 prepared under high quasihydrostatic pressure (2 GPa) and by hot pressing technique (30 MPa). It was shown that the SFCLs meet the main requirements to fault current limiters: they possess low impedance in the nominal regime of the protected circuit and can fast increase their impedance limiting both the transient and the steady-state fault currents. The study of quenching currents of MgB2 rings (SFCL activation current) and AC losses in the rings shows that the quenching current density and critical current density determined from AC losses can be 10-20 times less than the critical current determined from the magnetization experiments.

  12. Analysis and Modeling of Circulating Current in Two Parallel-Connected Inverters

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Gohil, Ghanshyamsinh Vijaysinh; Bede, Lorand

    2015-01-01

    Parallel-connected inverters are gaining attention for high power applications because of the limited power handling capability of the power modules. Moreover, the parallel-connected inverters may have low total harmonic distortion of the ac current if they are operated with the interleaved pulse...... this model, the circulating current between two parallel-connected inverters is analysed in this study. The peak and root mean square (rms) values of the normalised circulating current are calculated for different PWM methods, which makes this analysis a valuable tool to design a filter for the circulating......-width modulation (PWM). However, the interleaved PWM causes a circulating current between the inverters, which in turn causes additional losses. A model describing the dynamics of the circulating current is presented in this study which shows that the circulating current depends on the common-mode voltage. Using...

  13. Design of Jet lower hybrid current drive generator and operation of high power test bed

    International Nuclear Information System (INIS)

    Dobbing, J.A.; Bosia, G.; Brandon, M.; Gammelin, M.; Gormezano, C.; Jacquinot, J.; Jessop, G.; Lennholm, M.; Pain, M.; Sibley, A.

    1989-01-01

    The JET Lower Hybrid Current Drive (LHCD) generator consists of 24 klystrons each rated for 650 KW operating at 3.7 GHz, giving a nominal generator power of 15.6 MW for 10 seconds or 12 MW for 20 seconds. This power will be transmitted through 24 waveguides to a phased array launcher on one of the main ports of the JET machine. In addition, two klystrons are currently being operated on a high power test bed to establish reliable operation of the generators components and test high power microwave components prior to their installation

  14. Simulation as a key to success in power supply design and development

    Energy Technology Data Exchange (ETDEWEB)

    Suur-Askola, S.; Laasonen, M.; Maeki, J. [Efore Muuntolaite Oy, Vantaa (Finland)

    1997-12-31

    This paper describes the design and development process of a power supply by using simulation methods. The simulation principles and results of a 40W power supply are provided including EMI, voltage and current rating verification as well as power loss approximation. (orig.) 8 refs.

  15. Charged fusion product and fast ion loss in TFTR

    International Nuclear Information System (INIS)

    Zweben, S.J.; Darrow, D.S.; Fredrickson, E.D.; Mynick, H.E.; White, R.B.; Biglari, H.; Bretz, N.; Budny, R.; Bush, C.E.; Chang, C.S.; Chen, L.; Cheng, C.Z.; Fu, G.Y.; Hammett, G.W.; Hawryluk, R.J.; Hosea, J.; Johnson, L.; Mansfield, D.; McGuire, K.; Medley, S.S.; Nazikian, R.; Owens, D.K.; Park, H.; Park, J.; Phillips, C.K.; Schivell, J.; Stratton, B.C.; Ulrickson, M.; Wilson, R.; Young, K.M.; Fisher, R.; McChesney, J.; Fonck, R.; McKee, G.; Tuszewski, M.

    1993-03-01

    Several different fusion product and fast ion loss processes have been observed in TFTR using an array of pitch angle, energy and time resolved scintillator detectors located near the vessel wall. For D-D fusion products (3 MeV protons and 1 MeV tritons) the observed loss is generally consistent with expected first-orbit loss for Ip I MA. However, at higher currents, Ip = 1.4--2.5 MA, an NM induced D-D fusion product loss can be up to 3-4 times larger than the first-orbit loss, particularly at high beam powers, P ≥ 25 MW. The MHD induced loss of 100 KeV neutron beam ions and ∼0.5 MeV ICRF minority tail tons has also been measured ≤ 459 below the outer midplane. be potential implications of these results for D-T alpha particle experiments in TFTR and ITER are described

  16. CONCEPTS OF IMPROVING CURRENT PROTECTION OF POWER-GRID LINES

    Directory of Open Access Journals (Sweden)

    F. A. Romaniuk

    2015-01-01

    Full Text Available The  6–35  kV  power-grid  current  protection  serves  to  protect  the  transmission  lines against phase-to-phase short-circuits. The major disadvantage of it lies in the relatively large time delays of the last stages especially in the main sections of the grid owing to the stepped relay characteristics as well as a large number of the steps. A full-fledged protection of the 6–35 kV lines against inter-phase short circuits can be provided by the two-stage current protection: the first stage being the current cutoff without any time delay and the second stage – the maximum current protection where the time delay is linear contingent on the distance between the protection placement and the fault-point location. The article introduces the rating formulae for the time delays of the second-stage and their exemplary graphic presentation. The authors offer a variant for solving the problem with computation of the second-stage time delays in those instances where several feeders diverge from the bus bars of the substation located in the end of the protected line.Improving current protections for the 6–35 kV transmission lines with one-end power supply against interphase short-circuits can be based on the collective application of the following principles: accounting for the type and location of the short-circuit which provides for the high-performance cutoff zone instantaneous expansion and its independence on the mode of failure and the grid operation mode. It also allows increase of the last stage sensitiveness towards asymmetrical short-circuits; detection of the short-circuit location only on the results of fault currents measurement which simplifies the protection implementation; realization of the last (second protection stage with linear-dependent time delay which ensures potentiality of its operation speed increase.

  17. Radiation tolerant power converter controls

    CERN Document Server

    Todd, B; King, Q; Uznanski, S

    2012-01-01

    The Large Hadron Collider (LHC) at the European Organisation for Nuclear Research (CERN) is the world's most powerful particle collider. The LHC has several thousand magnets, both warm and super-conducting, which are supplied with current by power converters. Each converter is controlled by a purpose-built electronic module called a Function Generator Controller (FGC). The FGC allows remote control of the power converter and forms the central part of a closed-loop control system where the power converter voltage is set, based on the converter output current and magnet-circuit characteristics. Some power converters and FGCs are located in areas which are exposed to beam-induced radiation. There are numerous radiation induced effects, some of which lead to a loss of control of the power converter, having a direct impact upon the accelerator's availability. Following the first long shut down (LS1), the LHC will be able to run with higher intensity beams and higher beam energy. This is expected to lead to signifi...

  18. A fresh look at electron cyclotron current drive power requirements for stabilization of tearing modes in ITER

    Energy Technology Data Exchange (ETDEWEB)

    La Haye, R. J., E-mail: lahaye@fusion.gat.com [General Atomics, P.O. Box 85608, San Diego, California 92186-5608 (United States)

    2015-12-10

    ITER is an international project to design and build an experimental fusion reactor based on the “tokamak” concept. ITER relies upon localized electron cyclotron current drive (ECCD) at the rational safety factor q=2 to suppress or stabilize the expected poloidal mode m=2, toroidal mode n=1 neoclassical tearing mode (NTM) islands. Such islands if unmitigated degrade energy confinement, lock to the resistive wall (stop rotating), cause loss of “H-mode” and induce disruption. The International Tokamak Physics Activity (ITPA) on MHD, Disruptions and Magnetic Control joint experiment group MDC-8 on Current Drive Prevention/Stabilization of Neoclassical Tearing Modes started in 2005, after which assessments were made for the requirements for ECCD needed in ITER, particularly that of rf power and alignment on q=2 [1]. Narrow well-aligned rf current parallel to and of order of one percent of the total plasma current is needed to replace the “missing” current in the island O-points and heal or preempt (avoid destabilization by applying ECCD on q=2 in absence of the mode) the island [2-4]. This paper updates the advances in ECCD stabilization on NTMs learned in DIII-D experiments and modeling during the last 5 to 10 years as applies to stabilization by localized ECCD of tearing modes in ITER. This includes the ECCD (inside the q=1 radius) stabilization of the NTM “seeding” instability known as sawteeth (m/n=1/1) [5]. Recent measurements in DIII-D show that the ITER-similar current profile is classically unstable, curvature stabilization must not be neglected, and the small island width stabilization effect from helical ion polarization currents is stronger than was previously thought [6]. The consequences of updated assumptions in ITER modeling of the minimum well-aligned ECCD power needed are all-in-all favorable (and well-within the ITER 24 gyrotron capability) when all effects are included. However, a “wild card” may be broadening of the localized

  19. Normalised flood losses in Europe: 1970-2006

    Science.gov (United States)

    Barredo, J. I.

    2009-02-01

    This paper presents an assessment of normalised flood losses in Europe for the period 1970-2006. Normalisation provides an estimate of the losses that would occur if the floods from the past take place under current societal conditions. Economic losses from floods are the result of both societal and climatological factors. Failing to adjust for time-variant socio-economic factors produces loss amounts that are not directly comparable over time, but rather show an ever-growing trend for purely socio-economic reasons. This study has used available information on flood losses from the Emergency Events Database (EM-DAT) and the Natural Hazards Assessment Network (NATHAN). Following the conceptual approach of previous studies, we normalised flood losses by considering the effects of changes in population, wealth, and inflation at the country level. Furthermore, we removed inter-country price differences by adjusting the losses for purchasing power parities (PPP). We assessed normalised flood losses in 31 European countries. These include the member states of the European Union, Norway, Switzerland, Croatia, and the Former Yugoslav Republic of Macedonia. Results show no detectable sign of human-induced climate change in normalised flood losses in Europe. The observed increase in the original flood losses is mostly driven by societal factors.

  20. Current approaches to nuclear power plant life management in Japan

    International Nuclear Information System (INIS)

    Noda, T.; Tajima, K.; Ishikawa, M.; Koyama, M.

    2002-01-01

    extracted additional maintenance measures and incorporated them into their long-term maintenance plans, thereby reinforcing their current maintenance activities. Considering the latest information including domestic and overseas operating experiences and knowledge of academics and experts consigned by the Minister of Economy, Trade and Industry (METI), the Nuclear and Industry Safety Agency (NISA) of the METI reviewed and studied the technical evaluation and long-term maintenance plans of these electric utility companies. This paper describes the outlines of the NISA's report and related activities on current approaches to cope with the ageing of nuclear power plants in Japan. (Note) In 2001, the MITI was reorganized to the Ministry of Economy, Trade and Industry (METI). (author)

  1. An Envelope Correlation Formula for (N,N MIMO Antenna Arrays Using Input Scattering Parameters, and Including Power Losses

    Directory of Open Access Journals (Sweden)

    Y. A. S. Dama

    2011-01-01

    Full Text Available The scattering parameter formulation for the envelope correlation in an (N,N MIMO antenna array has been modified to take the intrinsic antenna power losses into account. This method of calculation provides a major simplification over the use of antenna radiation field patterns. Its accuracy is illustrated in three examples, which also show that the locations of the correlation minima are sensitive to the intrinsic losses.

  2. IMPROVING MODEL OF CHANNEL AIRBORN ELECTRICAL POWER SYSTEM OF ALTERNATING CURRENT

    Directory of Open Access Journals (Sweden)

    Yu. P. Artemenko

    2015-01-01

    Full Text Available This article is devoted to math modeling of channel of alternating current airborne electrical power-supply system. Mathematical modeling of generator, voltage regulator, constant speed drive is considered.

  3. Nuclear power in the Asia-Pacific region. Current status and future perspective

    International Nuclear Information System (INIS)

    Hao, Jia; Otsuki, Takashi; Irie, Kazutomo

    2017-01-01

    This paper presents the current status and future perspective of nuclear power in the APEC region. We design three scenarios, including Low-nuclear Scenario, Business-as-Usual Scenario (BAU) as well as High-nuclear Scenario, in order to quantitatively evaluate contribution of nuclear power to the low-carbon energy system. Preliminary results from the modeling are presented in the paper, and the drivers and challenges for nuclear power development in the APEC region are discussed. (author)

  4. Alternating current loss reduction for rectangular busbars by covering their edges with low permeable magnetic caps

    Energy Technology Data Exchange (ETDEWEB)

    Sasada, Ichiro, E-mail: sasada@ence.kyushu-u.ac.jp [Applied Science for Electronics and Materials, Kyushu University, Kasuga (Japan)

    2014-05-07

    A method to reduce ac conductive losses in a thin rectangular busbar made of copper is presented. The method is based on a technique, which makes the distribution of the ac current in the cross section of a busbar flatter. Edges of a thin busbar are covered with low permeability magnetic thin layers as caps. The magnetic cap makes the impedance experienced by the current flowing near the edge comparatively larger so that currents cannot get crowded near the edges of a busbar. This method is numerically verified.

  5. Measurement of AC losses in superconducting tapes by reproduction of thermometric dynamic response

    Energy Technology Data Exchange (ETDEWEB)

    Ligneris, Benoit des; Aubin, Marcel; Cave, Julian

    2003-04-15

    We have developed a dynamic response thermometric method for the measurement of AC losses in high T{sub c} superconductors. This method is based on the comparison of a temperature response caused by a known dissipation in the sample with that produced by the AC losses. By passing a DC current and measuring the DC voltage and corresponding temperature response the sample can be used as its own power dissipation reference. The advantages of this method are the short measurement duration time and the possibility to vary many experimental conditions: for example, AC and DC transport currents and AC, DC and rotating applied magnetic fields. In this article we present the basic method using variable short pulses of constant DC current for calibration and similarly of constant amplitude AC current to create the losses. The losses are obtained by numerical modelling and comparison of the thermometric dynamic response in the two above conditions. Finally, we present some experimental results for a Bi2223 superconducting tape at 50 Hz and 77 K.

  6. Advanced power flow technologies for high current ICF accelerators

    International Nuclear Information System (INIS)

    VanDevender, J.P.; McDaniel, D.H.

    1978-01-01

    Two new technologies for raising the power density in high current, inertial confinement fusion accelerators have been developed in the past two years. Magnetic flashover inhibition utilizes the self-magnetic fields around the vacuum insulator surface to inhibit surface flashover; average electric fields of 40 Mv/m at magnetic fields of 1.1 T have been achieved. Self-magnetic insulation of long, vacuum transmission lines has been used to transport power at 1.6 x 10 14 W/m 2 over six meters and up to 1.6 x 10 15 W/m 2 over short distances in a radial anode-cathode feed. The recent data relevant to these new technologies and their implications for ICF will be explored

  7. Power quality in electric distribution systems

    International Nuclear Information System (INIS)

    Mohamed, A.A.S.

    2005-01-01

    the power quality of the electric system is defined by the constant values of the voltage and frequency, the good value of the power factor close to unity, and balanced three phase voltages and currents. capacitors are widely installed in distribution systems for reactive power compensation to achieve power and energy loss reduction, voltage regulation and system capacity release. the extent of these benefits depends greatly on low the capacitors are placed on the system . the problem of how to place capacitors on the system such that these benefits are achieved and / or maximized against the cost associated with the capacitor placement is termed the general capacitor placement problem.the presented mathematical model has been developed to determine the size, number, and location of fixed capacitor banks that will maximize the saving derived from reduction in peak power and energy loss, and that will minimize the capital and installation costs of capacitors

  8. Adaptation to high current using low external resistances eliminates power overshoot in microbial fuel cells

    KAUST Repository

    Hong, Yiying

    2011-10-01

    One form of power overshoot commonly observed with mixed culture microbial fuel cells (MFCs) is doubling back of the power density curve at higher current densities, but the reasons for this type of overshoot have not been well explored. To investigate this, MFCs were acclimated to different external resistances, producing a range of anode potentials and current densities. Power overshoot was observed for reactors acclimated to higher (500 and 5000. Ω) but not lower (5 and 50. Ω) resistances. Acclimation of the high external resistance reactors for a few cycles to low external resistance (5. Ω), and therefore higher current densities, eliminated power overshoot. MFCs initially acclimated to low external resistances exhibited both higher current in cyclic voltammograms (CVs) and higher levels of redox activity over a broader range of anode potentials (-0.4 to 0. V; vs. a Ag/AgCl electrode) based on first derivative cyclic voltammetry (DCV) plots. Reactors acclimated to higher external resistances produced lower current in CVs, exhibited lower redox activity over a narrower anode potential range (-0.4 to -0.2. V vs. Ag/AgCl), and failed to produce higher currents above ∼-0.3. V (vs. Ag/AgCl). After the higher resistance reactors were acclimated to the lowest resistance they also exhibited similar CV and DCV profiles. Our findings show that to avoid overshoot, prior to the polarization and power density tests the anode biofilm must adapt to low external resistances to be capable of higher currents. © 2011 Elsevier B.V.

  9. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    International Nuclear Information System (INIS)

    Ha, Che-Wung; Lee, Do-Hwan

    2015-01-01

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources

  10. Open-Phase Condition Detecting System for Transformers in Nuclear Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Ha, Che-Wung; Lee, Do-Hwan [KHNP Central Research Institute, Daejeon (Korea, Republic of)

    2015-05-15

    Recently, several events involving the loss of one of the three phases of the offsite power circuit occurred in the US nuclear power plants (NPPs).. In some cases, the open-phase condition existed undetected for an extended period and in other case, was not properly responded to. Accordingly, the Nuclear Regulatory Commission (NRC) requested all license holders to take corrective actions to address the open-phase condition. It was also requested that all holders or applicant for a standard design certification (DC) include a description of a protection system to detect and separate the open circuit into design control document (DCD). Currently, NPPs including Duke Energy, Exelon, and institutes including Electric Power Research Institute (EPRI) are working together to resolve issues associated with detecting an open-phase condition. This paper, using Electromagnetic Transients Program (EMTP), presents a system to detect and address the loss of one of three phases of the offsite power circuit connected to main, auxiliary and standby transformers, which is hard to be detected in the current protection system. This paper, using EMTP, presents a system to detect and address the loss of one of three phases of the offsite power circuit running to MT, UAT or SAT which is hard to be detected in the current protection system. The system presented in this paper will be useful not only for the KHNP to meet the NRC requirement, but also for nuclear power plants at home and abroad to take corrective actions to provide protection from a single phase open circuit condition for offsite power sources.

  11. Vector Control Using Series Iron Loss Model of Induction, Motors and Power Loss Minimization

    OpenAIRE

    Kheldoun Aissa; Khodja Djalal Eddine

    2009-01-01

    The iron loss is a source of detuning in vector controlled induction motor drives if the classical rotor vector controller is used for decoupling. In fact, the field orientation will not be satisfied and the output torque will not truck the reference torque mostly used by Loss Model Controllers (LMCs). In addition, this component of loss, among others, may be excessive if the vector controlled induction motor is driving light loads. In this paper, the series iron loss model ...

  12. Beam size blow-up and current loss in the Fermilab Main Ring during storage

    International Nuclear Information System (INIS)

    Guignard, C.; Month, M.

    1977-01-01

    Observations at Fermilab during storage mode operation show characteristic forms of transverse beam size growth and current loss with time. There are three obvious mechanisms which can produce such blowup. The gas pressure is a source for immediate beam loss by direct nuclear scattering. Protons can also multiple scatter off the orbiting electrons of the gas atoms causing the trasnverse beam size to increase with time. A third mechanism not related to gas pressure is beam growth due to multiple crossing of betatron resonances arising from the synchrotron oscillations of the stored bunches. This simulates a random walk and causes the transverse beam size to grow. This is an attempt to describe the observations with direct nuclear scattering, multiple coulomb scattering, and multiple resonance crossing

  13. Long-term security of electrical and control engineering equipment in nuclear power stations to withstand a loss of coolant accident

    International Nuclear Information System (INIS)

    Mueller, H.

    1996-01-01

    Electrical and control engineering equipment, which has to function even after many years of operation in the event of a fault in a saturated steam atmosphere of 160 C maximum, is essential in nuclear power stations in order to control a loss of coolant accident. The nuclear power station operators have, for this purpose, developed verification strategies for groups of components, by means of which it is ensured that the electrical and control engineering components are capable of dealing with a loss of coolant accident even at the end of their planned operating life. (orig.) [de

  14. Icing losses on wind turbines

    Energy Technology Data Exchange (ETDEWEB)

    Duncan, T.; Fotsing, I.; Pearson, S. [Garrad Hassan Canada Inc., Ottawa, ON (Canada)

    2010-07-01

    This PowerPoint presentation discussed some of the energy losses that can occur as a result of icing on wind turbines. Airfoil deterioration can occur in the presence of rime and glaze ice. Anemometers are also impacted by ice, and shut-downs can occur as a result of icing events. Availability deficits that occur during the winter months can lead to annual energy losses of 0.5 percent. The impact of icing events on total wind power energy production in Quebec is estimated at between 1.3 percent to 2.7 percent. Ice loss estimates are considered during the pre-construction phases of wind power projects. However, ice loss prediction methods are often inaccurate. Studies have demonstrated that preconstruction masts show a reasonable correlation with wind turbine icing, and that icing losses are site-specific. tabs., figs.

  15. Variable speed DFIG wind energy system for power generation and harmonic current mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Gaillard, A.; Saadate, S. [Groupe de Recherche en Electrotechnique et Electronique de Nancy, Nancy Universite - Universite Henri Poincare Nancy 1, BP239, 54506 Vandoeuvre les Nancy Cedex (France); Poure, P. [Laboratoire d' Instrumentation Electronique de Nancy, Nancy Universite - Universite Henri Poincare Nancy 1, BP239, 54506 Vandoeuvre les Nancy Cedex (France); Machmoum, M. [IREENA, 37 Boulevard de l' Universite, BP 406, 44602 Saint-Nazaire Cedex (France)

    2009-06-15

    This paper presents a novel approach for simultaneous power generation and harmonic current mitigation using variable speed WECS with DFIG. A new control strategy is proposed to upgrade the DFIG control to achieve simultaneously a green active and reactive power source with active filtering capability. To ensure high filtering performance, we studied an improved harmonic isolator in the time-domain, based on a new high selectivity filter developed in our laboratory. We examined two solutions for harmonic current mitigation: first, by compensating the whole harmonic component of the grid currents or second, by selective isolation of the predominant harmonic currents to ensure active filtering of the 5th and 7th harmonics. Simulation results for a 3 MW WECS with DFIG confirm the effectiveness and the performance of the two proposed approaches. (author)

  16. New digital reference current generation for shunt active power filter under distorted voltage conditions

    Energy Technology Data Exchange (ETDEWEB)

    Abdusalam, Mohamed; Karimi, Shahram; Saadate, Shahrokh [Groupe de Recherche en Electrotechnique et Electronique de Nancy (GREEN), CNRS UMR 7037 (France); Poure, Philippe [Laboratoire d' Instrumentation Electronique de Nancy (LIEN), EA 3440, Universite Henri Poincare - Nancy Universite, B.P. 239, 54506 Vandoeuvre les Nancy Cedex (France)

    2009-05-15

    In this paper, a new reference current computation method suitable for shunt active power filter control under distorted voltage conditions is proposed. The active power filter control is based on the use of self-tuning filters (STF) for the reference current generation and on a modulated hysteresis current controller. This active filter is intended for harmonic compensation of a diode rectifier feeding a RL load under distorted voltage conditions. The study of the active filter control is divided in two parts. The first one deals with the harmonic isolator which generates the harmonic reference currents and is experimentally implemented in a DS1104 card of a DSPACE prototyping system. The second part focuses on the generation of the switching pattern of the inverter by using a modulated hysteresis current controller, implemented in an analogue card. The use of STF instead of classical extraction filters allows extracting directly the voltage and current fundamental components in the {alpha}-{beta} axis without phase locked loop (PLL). The performances are good even under distorted voltage conditions. First, the effectiveness of the new proposed method is mathematically studied and verified by computer simulation. Then, experimental results are presented using a DSPACE system associated with the analogue current controller for a real shunt active power filter. (author)

  17. Assessing harmonic current source modelling and power definitions in balanced and unbalanced networks

    Energy Technology Data Exchange (ETDEWEB)

    Atkinson-Hope, Gary; Stemmet, W.C. [Cape Peninsula University of Technology, Cape Town Campus, Cape Town (South Africa)

    2006-07-01

    The purpose of this paper is to assess the DlgSILENT PowerFactory software power definitions (indices) in terms of phase and sequence components for balanced and unbalanced networks when harmonic distortion is present and to compare its results to hand calculations done, following recommendation made by the IEEE Working Group on this topic. This paper also includes the development of a flowchart for calculating power indices in balanced and unbalanced three-phase networks when non-sinusoidal voltages and currents are present. A further purpose is to determine how two industrial grade harmonic analysis software packages (DlgSILENT and ERACS) model three-phase harmonic sources used for current penetration studies and to compare their results when applied to a network. From the investigations, another objective was to develop a methodology for modelling harmonic current sources based on a spectrum obtained from measurements. Three case studies were conducted and the assessment and developed methodologies were shown to be effective. (Author)

  18. Loss of Synchronism of Wind Turbine Converters during Low Voltage Grid Faults

    DEFF Research Database (Denmark)

    Göksu, Ömer; Sørensen, Poul Ejnar; Iov, Florin

    2014-01-01

    In the recent grid codes, wind power plants are required to stay connected and inject reactive and active currents during grid short-circuit faults, even when the grid voltage drops down to zero. However, the physical fact, Loss of Synchronism (LOS) of wind turbines during these very low voltage ...... as whole. Additionally, existing methods to solve the LOS problem are briefly reviewed, and a closed loop frequency based solution is implemented within PowerFactory simulations of a detailed generic wind power plant model....

  19. Electron cyclotron current drive in the Wendelstein 7-AS stellarator

    Energy Technology Data Exchange (ETDEWEB)

    Maassberg, H [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Rome, M [I.N.F.N., I.N.F.M., Dipartimento di Fisica, Universita degli Studi, I-20133 Milan (Italy); Erckmann, V [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Geiger, J [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Laqua, H P [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany); Marushchenko, N B [Max-Planck Institut fuer Plasmaphysik, EURATOM Association, D-85748 Garching (Germany)

    2005-08-01

    High power electron cyclotron current drive (ECCD) experiments in the W7-AS stellarator are analysed. In these net-current-free discharges, the ECCD and the bootstrap current are feedback controlled by an inductive current. Based on the measured density and temperature profiles, the neoclassical predictions of the bootstrap (with the ambipolar radial electric field taken into account) and the inductive current densities as well as the ECCD from the linear adjoint approach with trapped particles included are calculated. For stationary conditions, the current balance is checked. Launch-angle scans at fixed density as well as density scans at fixed launch-angle are described. Low-frequency MHD mode activity is obtained for strong co-ECCD, and for counter-ECCD a ' {iota}-bar approx.= 0 feature' with complete loss of the central confinement is found. The linear ECCD prediction is in reasonable agreement with the current balance except for low-density discharges with highly peaked on-axis deposition, where the ECCD predicted from linear theory exceeds by a factor of about 2 the one from the current balance. Since the bootstrap current is well balanced by the inductive current without ECCD, the linear ECCD overestimate is compared with nonlinear Fokker-Planck (FP) simulations, where two different power loss models are used to reach steady state. These volume-averaged FP simulations cannot describe the ECCD degradation at the low densities.

  20. Electron cyclotron current drive in the Wendelstein 7-AS stellarator

    International Nuclear Information System (INIS)

    Maassberg, H; Rome, M; Erckmann, V; Geiger, J; Laqua, H P; Marushchenko, N B

    2005-01-01

    High power electron cyclotron current drive (ECCD) experiments in the W7-AS stellarator are analysed. In these net-current-free discharges, the ECCD and the bootstrap current are feedback controlled by an inductive current. Based on the measured density and temperature profiles, the neoclassical predictions of the bootstrap (with the ambipolar radial electric field taken into account) and the inductive current densities as well as the ECCD from the linear adjoint approach with trapped particles included are calculated. For stationary conditions, the current balance is checked. Launch-angle scans at fixed density as well as density scans at fixed launch-angle are described. Low-frequency MHD mode activity is obtained for strong co-ECCD, and for counter-ECCD a ' ι-bar approx.= 0 feature' with complete loss of the central confinement is found. The linear ECCD prediction is in reasonable agreement with the current balance except for low-density discharges with highly peaked on-axis deposition, where the ECCD predicted from linear theory exceeds by a factor of about 2 the one from the current balance. Since the bootstrap current is well balanced by the inductive current without ECCD, the linear ECCD overestimate is compared with nonlinear Fokker-Planck (FP) simulations, where two different power loss models are used to reach steady state. These volume-averaged FP simulations cannot describe the ECCD degradation at the low densities

  1. Harnessing the Ocean's Power : Energy from Waves and Currents (Part I)

    OpenAIRE

    Yukihisa, Washio; Japan Marine Science and Technology Center

    1985-01-01

    The oceans are a potential source of renewable and pollution-free energy of particular importance to Japan. In this Issue we look at current development work to harness wave energy for power generation.

  2. A Tariff for Reactive Power

    Energy Technology Data Exchange (ETDEWEB)

    Kueck, John D [ORNL; Kirby, Brendan J [ORNL; Li, Fangxing [ORNL; Tufon, Christopher [Pacific Gas and Electric Company; Isemonger, Alan [California Independent System Operator

    2008-07-01

    Two kinds of power are required to operate an electric power system: real power, measured in watts, and reactive power, measured in volt-amperes reactive or VARs. Reactive power supply is one of a class of power system reliability services collectively known as ancillary services, and is essential for the reliable operation of the bulk power system. Reactive power flows when current leads or lags behind voltage. Typically, the current in a distribution system lags behind voltage because of inductive loads such as motors. Reactive power flow wastes energy and capacity and causes voltage droop. To correct lagging power flow, leading reactive power (current leading voltage) is supplied to bring the current into phase with voltage. When the current is in phase with voltage, there is a reduction in system losses, an increase in system capacity, and a rise in voltage. Reactive power can be supplied from either static or dynamic VAR sources. Static sources are typically transmission and distribution equipment, such as capacitors at substations, and their cost has historically been included in the revenue requirement of the transmission operator (TO), and recovered through cost-of-service rates. By contrast, dynamic sources are typically generators capable of producing variable levels of reactive power by automatically controlling the generator to regulate voltage. Transmission system devices such as synchronous condensers can also provide dynamic reactive power. A class of solid state devices (called flexible AC transmission system devices or FACTs) can provide dynamic reactive power. One specific device has the unfortunate name of static VAR compensator (SVC), where 'static' refers to the solid state nature of the device (it does not include rotating equipment) and not to the production of static reactive power. Dynamic sources at the distribution level, while more costly would be very useful in helping to regulate local voltage. Local voltage regulation would

  3. Modified loss coefficients in the determination of optimum generation scheduling

    Energy Technology Data Exchange (ETDEWEB)

    Hazarika, D.; Bordoloi, P.K. (Assam Engineering Coll. (IN))

    1991-03-01

    A modified method has been evolved to form the loss coefficients of an electrical power system network by decoupling load and generation and thereby creating additional fictitious load buses. The system losses are then calculated and co-ordinated to arrive at an optimum scheduling of generation using the standard co-ordination equation. The method presented is superior to the ones currently available, in that it is applicable to a multimachine system with random variation of load and it accounts for limits in plant generations and line losses. The precise nature of results and the economy in the cost of energy production obtained by this method is quantified and presented. (author).

  4. Transformer failure and common-mode loss of instrument power at Nine Mile Point Unit 2 on August 13, 1991

    Energy Technology Data Exchange (ETDEWEB)

    1991-10-01

    On August 13, 1991, at Nine Mile Point Unit 2 nuclear power plant, located near Scriba, New York, on Lake Ontario, the main transformer experienced an internal failure that resulted in degraded voltage which caused the simultaneous loss of five uninterruptible power supplies, which in turn caused the loss of several nonsafety systems, including reactor control rod position indication, some reactor power and water indication, control room annunciators, the plant communications system, the plant process computer, and lighting at some locations. The reactor was subsequently brought to a safe shutdown. Following this event, the US Nuclear Regulatory Commission dispatched an Incident Investigation Team to the site to determine what happened, to identify the probable causes, and to make appropriate findings and conclusions. This report describes the incident, the methodology used by the team in its investigation, and presents and the team's findings and conclusions. 59 figs., 14 tabs.

  5. Transformer failure and common-mode loss of instrument power at Nine Mile Point Unit 2 on August 13, 1991

    International Nuclear Information System (INIS)

    1991-10-01

    On August 13, 1991, at Nine Mile Point Unit 2 nuclear power plant, located near Scriba, New York, on Lake Ontario, the main transformer experienced an internal failure that resulted in degraded voltage which caused the simultaneous loss of five uninterruptible power supplies, which in turn caused the loss of several nonsafety systems, including reactor control rod position indication, some reactor power and water indication, control room annunciators, the plant communications system, the plant process computer, and lighting at some locations. The reactor was subsequently brought to a safe shutdown. Following this event, the US Nuclear Regulatory Commission dispatched an Incident Investigation Team to the site to determine what happened, to identify the probable causes, and to make appropriate findings and conclusions. This report describes the incident, the methodology used by the team in its investigation, and presents and the team's findings and conclusions. 59 figs., 14 tabs

  6. Nuclear power in the OECD countries results and current issues

    International Nuclear Information System (INIS)

    Jones, C.F.

    1989-01-01

    The first use of nuclear power for the generation of electricity on a commercial scale occurred in the United Kingdom in 1956. Today, 13 OECD countries have 318 nuclear units in operation and 66 more in construction or on order. This outstanding achievement is the result of the successful organization, start up, and operation of an industry to design, build, equip, fuel, and maintain these facilites. Nuclear power, however, is currently troubled by a number of issues that may impair its ability to reach its full potential. The industry has acknowledged problems that can be and are being managed. But the industry also has a number of political difficulties that could be beyond its ability to resolve with its own resources. These are issues common to the introduction of new technologies into a complex world. Nevertheless, nuclear power continues to be the means by which we can provide the electric power needed to raise the living standard of everyone on the globe

  7. Losses in electric motors caused by harmonics; Harmoniske overtoners betydning for tabene i elmotorer

    Energy Technology Data Exchange (ETDEWEB)

    Johansson, M. [Dansk Energi Analyse A/S, Glostrup (Denmark); Kehr, J.M. [ABB A/S, Skovlunde (Denmark); Hoejte Hansen, H. [Balslev A/S, Glostrup (Denmark)

    2012-03-15

    The purpose of the project was to provide evidence of power saving based on measurements in electric installations, in which the harmonics were reduced by active filters. The project has included knowledge building on the basis of literature and discussions with a Swedish and a Belgian producer of active filters. In connection with the project, tests have been made on a production line at the firm of Faerch Plast, where the distortion from the harmonics, measured as THDU, was 6 to 7 %. Measurements during two days with the active filter switched on and off with an interval of 10 minutes showed a very small difference in power input in the two situations. The power was 2.7 kW higher with connected filter than without filter. As the own consumption of the filter was 5.8 kW, the consumption of the installation itself was 3.1 kW lower, equal to 1 % of the load of the directly supplied induction motors. As a consequence of the very small differences, measured at Faerch Plast, it was decided to transfer the further work to a laboratory in order to measure under so controlled circumstances as possible. Measurements have been taken at KME (Copenhagen School of Marine Engineering and Technology Management) and at TI (Danish Technological Institute). The result of measurements on a 5.5 kW induction motor with a distortion from the harmonics (THDU) of 2.65 % shows no significant change in the input power compared to the situation with almost no distortion. Neither, it appears, is there a significant difference in the motor losses in a situation, where the measurement was taken with two rather distorted mains voltages with a THDU of 6.33 % and 7.66 %, respectively. Calculations on the basis of the equivalent diagram of the motor show that the additional motor losses in a 5.5 kW motor as a consequence of 5. harmonics of 5 % of the mains voltage (THDU 5 %) only is 2 W, while an experimentally derived formula results in a difference of approx 9 W or 0.2 % of the rated power of

  8. MOSFET Loss Evaluation for a Low-Power Stand-Alone Photovoltaic-LED System

    DEFF Research Database (Denmark)

    Mira Albert, Maria del Carmen; Knott, Arnold; Andersen, Michael A. E.

    2015-01-01

    This paper presents a performance evaluation and comparison of state-of-the-art low voltage Si MOSFETs for a stand-alone photovoltaic-LED Light to Light (LtL) system. The complete system is formed by two cascaded converters that will be optimized for a determined solar irradiation and LED...... illumination profiles. The comparison is performed based on dynamic characterization and evaluation of the devices energy loss at different current levels....

  9. Adaptive Hysteresis Band Current Control (AHB) with PLL of Grid Side Converter-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2011-01-01

    Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given......, transformer and grid, and control parts, etc. The simulation results have verified that the control strategy is feasible to fit for control of gird currents, active power, reactive power and DC-link voltage in wind power generation system....

  10. A new approach for AC loss reduction in HTS transformer using auxiliary windings, case study: 25 kA HTS current injection transformer

    Science.gov (United States)

    Heydari, Hossein; Faghihi, Faramarz; Aligholizadeh, Reza

    2008-01-01

    AC loss is one of the important parameters in HTS (high temperature superconducting) AC devices. Among the HTS AC power devices, the transformer is an essential part in the electrical power system. The AC losses in an HTS tape depend on the magnetic field. One of the techniques usually adopted to mitigate the unwanted magnetic field is using a system of coils that produce a magnetic field opposite to the incident one, reducing the total magnetic field. In this paper adding two auxiliary windings to the HTS transformer to produce this opposite magnetic field is proposed. The proper use of these auxiliary windings could reduce the leakage flux and, therefore, the AC loss. A mathematical model is used to describe the behaviour of a transformer operating with auxiliary windings, based on the theory of electromagnetic coupled circuits. The influence of the auxiliary windings on the leakage field is studied by the finite element method (FEM) and the AC loss of an HTS transformer was calculated. Also, the simulation results show that employing auxiliary windings will improve the HTS transformer efficiency.

  11. A new approach for AC loss reduction in HTS transformer using auxiliary windings, case study: 25 kA HTS current injection transformer

    International Nuclear Information System (INIS)

    Heydari, Hossein; Faghihi, Faramarz; Aligholizadeh, Reza

    2008-01-01

    AC loss is one of the important parameters in HTS (high temperature superconducting) AC devices. Among the HTS AC power devices, the transformer is an essential part in the electrical power system. The AC losses in an HTS tape depend on the magnetic field. One of the techniques usually adopted to mitigate the unwanted magnetic field is using a system of coils that produce a magnetic field opposite to the incident one, reducing the total magnetic field. In this paper adding two auxiliary windings to the HTS transformer to produce this opposite magnetic field is proposed. The proper use of these auxiliary windings could reduce the leakage flux and, therefore, the AC loss. A mathematical model is used to describe the behaviour of a transformer operating with auxiliary windings, based on the theory of electromagnetic coupled circuits. The influence of the auxiliary windings on the leakage field is studied by the finite element method (FEM) and the AC loss of an HTS transformer was calculated. Also, the simulation results show that employing auxiliary windings will improve the HTS transformer efficiency

  12. A new approach for AC loss reduction in HTS transformer using auxiliary windings, case study: 25 kA HTS current injection transformer

    Energy Technology Data Exchange (ETDEWEB)

    Heydari, Hossein; Faghihi, Faramarz; Aligholizadeh, Reza [Center of Excellence for Power System Automation and Operation, Electrical Engineering Department, Iran University of Science and Technology, Tehran (Iran, Islamic Republic of)

    2008-01-15

    AC loss is one of the important parameters in HTS (high temperature superconducting) AC devices. Among the HTS AC power devices, the transformer is an essential part in the electrical power system. The AC losses in an HTS tape depend on the magnetic field. One of the techniques usually adopted to mitigate the unwanted magnetic field is using a system of coils that produce a magnetic field opposite to the incident one, reducing the total magnetic field. In this paper adding two auxiliary windings to the HTS transformer to produce this opposite magnetic field is proposed. The proper use of these auxiliary windings could reduce the leakage flux and, therefore, the AC loss. A mathematical model is used to describe the behaviour of a transformer operating with auxiliary windings, based on the theory of electromagnetic coupled circuits. The influence of the auxiliary windings on the leakage field is studied by the finite element method (FEM) and the AC loss of an HTS transformer was calculated. Also, the simulation results show that employing auxiliary windings will improve the HTS transformer efficiency.

  13. 7 CFR 760.611 - Qualifying losses, eligible causes and types of loss.

    Science.gov (United States)

    2010-01-01

    ... final planting date; (4) The cause of loss was due to water contained or released by any governmental... containment or release of the water; (5) The cause of loss was due to conditions or events occurring outside...) Losses caused by a failure of power supply or brownout as defined in § 760.602; (2) Losses caused by the...

  14. Loss of Excitation Detection in Doubly Fed Induction Generator by Voltage and Reactive Power Rate

    Directory of Open Access Journals (Sweden)

    M. J. Abbasi

    2016-12-01

    Full Text Available The doubly fed induction generator (DFIG is one of the most popular technologies used in wind power systems. With the growing use of DFIGs and increasing power system dependence on them in recent years, protecting of these generators against internal faults is more considered. Loss of excitation (LOE event is among the most frequent failures in electric generators. However, LOE detection studies heretofore were usually confined to synchronous generators. Common LOE detection methods are based on impedance trajectory which makes the system slow and also prone to interpret a stable power swing (SPS as a LOE fault. This paper suggests a new method to detect the LOE based on the measured variables from the DFIG terminal. In this combined method for LOE detection, the rate of change of both the terminal voltage and the output reactive power are utilized and for SPS detection, the fast Fourier transform (FFT analysis of the output instantaneous active power has been used. The performance of the proposed method was evaluated using Matlab/Simulink interface for various power capacities and operating conditions. The results proved the method's quickness, simplicity and security.

  15. Estimation and reduction of harmonic currents from power converters

    DEFF Research Database (Denmark)

    Asiminoaei, Lucian

    -based method depends very much on the amount and accuracy of collected data in the development stage. The outcome of this investigation is a Harmonic Calculation Software compiled into a Graphical User Interface PC-software application, which can be applied for fast estimations of the harmonic currents...... control of the proposed topologies are given together with laboratory tests. One harmonic current mitigation solution found is to connect (two) smaller power APF's in parallel, sharing the same ac- and dc-bus. It is proven that parallel APF's may have lower passive components although other issues arises......, like circulation currents, which is removed here by common mode coils. Another harmonic solution is to use cascade connection of (two) independent APF's that cooperatively share the task of the harmonic mitigation. Two cooperative control methods are proposed called load-sharing and harmonic-sharing...

  16. MAGY: An innovative high voltage-low current power supply for gyrotron

    International Nuclear Information System (INIS)

    Siravo, Ugo; Alex, Juergen; Bader, Michael; Carpita, Mauro; Fasel, Damien; Gavin, Serge; Perez, Albert

    2011-01-01

    From the electrical point of view, the body and the anode of high power gyrotrons behave as capacitive loads. A highly dynamic power supply is, therefore, hard to achieve. The MAGY concept (Modulator for the Anode of a triode type GYrotron) embodies an innovative solution to manage the capacitive current ensuring a very low ripple on the output voltage. It consists of a series of independent, bi-directional and regulated DC sources. Compared to existing topologies, this solution requires a smaller number of power modules. It avoids internal high frequency modulation and simultaneously offers high resolution of the output voltage and a wide range of operating scenarios.

  17. Operating experience feedback on lose of offsite power supply for nuclear power plant

    International Nuclear Information System (INIS)

    Jiao Feng; Hou Qinmai; Che Shuwei

    2013-01-01

    The function of the service power system of a nuclear power plant is to provide safe and reliable power supply for the nuclear power plant facilities. The safety of nuclear power plant power supply is essential for nuclear safety. The serious accident of Fukushima Daiichi nuclear power plant occurred due to loss of service power and the ultimate heat sink. The service power system has two independent offsite power supplies as working power and auxiliary power. This article collected events of loss of offsite power supply in operating nuclear power plants at home and abroad, and analyzed the plant status and cause of loss of offsite power supply events, and proposed improvement measures for dealing with loss of offsite power supply. (authors)

  18. A Component-Minimized Single-Phase Active Power Decoupling Circuit with Reduced Current Stress to Semiconductor Switches

    DEFF Research Database (Denmark)

    Tang, Yi; Blaabjerg, Frede

    2015-01-01

    inductor. With such a configuration, this leg can control the current going into the two output capacitors connected in series for power decoupling, and the other leg can control the line current according to active and reactive power requirement. The proposed topology does not require additional passive...... component, e.g. inductors or film capacitors for ripple energy storage because this task can be accomplished by the dc-link capacitors, and therefore its implementation cost can be minimized. Another unique feature of the proposed topology is that the current stress of power semiconductors can be reduced...

  19. Minimization of distribution system losses by exploiting storage and anticipating market-driven behaviour of wind power producers

    NARCIS (Netherlands)

    Farrokhseresht, M.; Paterakis, N.G.; Gibescu, M.; Slootweg, J.G.

    2017-01-01

    This paper presents a stochastic bi-level optimization model to determine the optimal dispatch of energy storage systems controlled directly by the distribution system operator (DSO) in order to achieve minimization of active power losses, taking into account the profit-driven participation of

  20. Behaviour of a pressurized-water reactor nuclear power plant during loss-of-coolant accident

    International Nuclear Information System (INIS)

    Adam, E.; Carl, H.; Kubis, K.

    1979-01-01

    Starting from the foundation of the design basis accident in a PWR-type nuclear power plant - Loss of Coolant Accident -the actual status of the processes to be expected in the reactor are described. Operating behaviour of the heat removal system and efficiency of the safety systems are evaluated. Final considerations are concerned with the overall behaviour of the plant under such conditions. Probable failures, shut down times and possibilities of repair are estimated. (author)