WorldWideScience

Sample records for current diagnostic techniques

  1. Proton current measurements using the prompt gamma ray diagnostic technique

    International Nuclear Information System (INIS)

    Leeper, R.J.; Burns, E.J.T.; Johnson, D.J.; McMurtry, W.M.

    1981-01-01

    Prompt gamma ray signals from the nuclear reaction 7 Li(p,γ) 8 Be have been used to make time resolved proton current measurements. In these measurements, the proton beam was allowed to strike cylindrical thick lithium metal targets. The time integrated proton current was measured using gamma activation of copper via the reaction 63 Cu(γ,n) 62 Cu(β+). The positron activity of the copper sample was easily measured using coincidence counting techniques. The number of 62 Cu atoms produced per proton incident on a thick Li metal target was determined with separate calibration runs performed on the Sandia 2.5 MeV Van de Graaff accelerator. The time history of the prompt gamma production was measured using six EGG NPM-54 scintillator photomultiplier combinations shielded by 96.5 cm of concrete and 5.1 cm of Pb. The use of six scintillator photomultiplier combinations was necessary to increase the statistical precision of the data. The normalization of the prompt gamma time history data with the total time integrated proton-current measurement yielded the absolute time resolved proton current on target. Data from runs performed on the Sandia Proto I accelerator will be presented

  2. Diagnostic techniques

    International Nuclear Information System (INIS)

    Berquist, T.H.; Bender, C.E.; James, E.M.; Brown, M.L.; McLeod, R.A.; Broderick, D.F.; Welch, T.J.

    1989-01-01

    Proper application of imaging procedures is essential to obtain needed information for diagnosis and therapy planning in patients with suspected foot and/or ankle pathology. This paper provides basic background data for the numerous imaging techniques

  3. An efficient diagnostic technique for distribution systems based on under fault voltages and currents

    Energy Technology Data Exchange (ETDEWEB)

    Campoccia, A.; Di Silvestre, M.L.; Incontrera, I.; Riva Sanseverino, E. [Dipartimento di Ingegneria Elettrica elettronica e delle Telecomunicazioni, Universita degli Studi di Palermo, viale delle Scienze, 90128 Palermo (Italy); Spoto, G. [Centro per la Ricerca Elettronica in Sicilia, Monreale, Via Regione Siciliana 49, 90046 Palermo (Italy)

    2010-10-15

    Service continuity is one of the major aspects in the definition of the quality of the electrical energy, for this reason the research in the field of faults diagnostic for distribution systems is spreading ever more. Moreover the increasing interest around modern distribution systems automation for management purposes gives faults diagnostics more tools to detect outages precisely and in short times. In this paper, the applicability of an efficient fault location and characterization methodology within a centralized monitoring system is discussed. The methodology, appropriate for any kind of fault, is based on the use of the analytical model of the network lines and uses the fundamental components rms values taken from the transient measures of line currents and voltages at the MV/LV substations. The fault location and identification algorithm, proposed by the authors and suitably restated, has been implemented on a microprocessor-based device that can be installed at each MV/LV substation. The speed and precision of the algorithm have been tested against the errors deriving from the fundamental extraction within the prescribed fault clearing times and against the inherent precision of the electronic device used for computation. The tests have been carried out using Matlab Simulink for simulating the faulted system. (author)

  4. Modern Diagnostic Techniques for the Assessment of Ocular Blood Flow in Myopia: Current State of Knowledge.

    Science.gov (United States)

    Grudzińska, Ewa; Modrzejewska, Monika

    2018-01-01

    Myopia is the most common refractive error and the subject of interest of various studies assessing ocular blood flow. Increasing refractive error and axial elongation of the eye result in the stretching and thinning of the scleral, choroid, and retinal tissues and the decrease in retinal vessel diameter, disturbing ocular blood flow. Local and systemic factors known to change ocular blood flow include glaucoma, medications and fluctuations in intraocular pressure, and metabolic parameters. Techniques and tools assessing ocular blood flow include, among others, laser Doppler flowmetry (LDF), retinal function imager (RFI), laser speckle contrast imaging (LSCI), magnetic resonance imaging (MRI), optical coherence tomography angiography (OCTA), pulsatile ocular blood flowmeter (POBF), fundus pulsation amplitude (FPA), colour Doppler imaging (CDI), and Doppler optical coherence tomography (DOCT). Many researchers consistently reported lower blood flow parameters in myopic eyes regardless of the used diagnostic method. It is unclear whether this is a primary change that causes secondary thinning of ocular tissues or quite the opposite; that is, the mechanical stretching of the eye wall reduces its thickness and causes a secondary lower demand of tissues for oxygen. This paper presents a review of studies assessing ocular blood flow in myopes.

  5. Comparison of advanced optical imaging techniques with current otolaryngology diagnostics for improved middle ear assessment (Conference Presentation)

    Science.gov (United States)

    Nolan, Ryan M.; Shelton, Ryan L.; Monroy, Guillermo L.; Spillman, Darold R.; Novak, Michael A.; Boppart, Stephen A.

    2016-02-01

    Otolaryngologists utilize a variety of diagnostic techniques to assess middle ear health. Tympanometry, audiometry, and otoacoustic emissions examine the mobility of the tympanic membrane (eardrum) and ossicles using ear canal pressure and auditory tone delivery and detection. Laser Doppler vibrometry provides non-contact vibrational measurement, and acoustic reflectometry is used to assess middle ear effusion using sonar. These technologies and techniques have advanced the field beyond the use of the standard otoscope, a simple tissue magnifier, yet the need for direct visualization of middle ear disease for superior detection, assessment, and management remains. In this study, we evaluated the use of portable optical coherence tomography (OCT) and pneumatic low-coherence interferometry (LCI) systems with handheld probe delivery to standard tympanometry, audiometry, otoacoustic emissions, laser Doppler vibrometry, and acoustic reflectometry. Comparison of these advanced optical imaging techniques and current diagnostics was conducted with a case study subject with a history of unilateral eardrum trauma. OCT and pneumatic LCI provide novel dynamic spatiotemporal structural data of the middle ear, such as the thickness of the eardrum and quantitative detection of underlying disease pathology, which could allow for more accurate diagnosis and more appropriate management than currently possible.

  6. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A; Laird, J S; Bardos, R A; Legge, G J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T; Sekiguchi, H [Electrotechnical Laboratory, Tsukuba (Japan).

    1994-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  7. Low current beam techniques

    Energy Technology Data Exchange (ETDEWEB)

    Saint, A.; Laird, J.S.; Bardos, R.A.; Legge, G.J.F. [Melbourne Univ., Parkville, VIC (Australia). School of Physics; Nishijima, T.; Sekiguchi, H. [Electrotechnical Laboratory, Tsukuba (Japan).

    1993-12-31

    Since the development of Scanning Transmission Microscopy (STIM) imaging in 1983 many low current beam techniques have been developed for the scanning (ion) microprobe. These include STIM tomography, Ion Beam Induced Current, Ion Beam Micromachining and Microlithography and Ionoluminense. Most of these techniques utilise beam currents of 10{sup -15} A down to single ions controlled by beam switching techniques This paper will discuss some of the low beam current techniques mentioned above, and indicate, some of their recent applications at MARC. A new STIM technique will be introduced that can be used to obtain Z-contrast with STIM resolution. 4 refs., 3 figs.

  8. Adaptive techniques for diagnostics of vibrating structures

    International Nuclear Information System (INIS)

    Skormin, V.A.; Sankar, S.

    1983-01-01

    An adaptive diagnostic procedure for vibrating structures based on correspondence between current estimates of stiffness matrix and structure status is proposed. Procedure employs adaptive mathematical description of the vibrating structure in frequency domain, statistical techniques for detection and location of changes of structure properties, 'recognition' and prediction of defects. (orig.)

  9. Prostate carcinoma: current diagnostic strategy

    International Nuclear Information System (INIS)

    Schwarzschild, Monica Maria Agata Stiepcich; Ferraz, Maria Lucia Cardoso Gomes; Oliveira, Jose Marcelo Amatuzzi; Andriolo, Adagmar

    2001-01-01

    Prostate cancer is the second cause of cancer death in men in the Western world. Despite progress in the treatment of advanced disease, it is recognized that the only possibility of reduction in prostate cancer death is nearly diagnosis when the disease is localized. In the present study our aim was to review the current strategy for diagnosis of prostate carcinoma. Prostate-specific antigen (PSA) is a valuable tumor marker and has demonstrated effectiveness in detecting prostate carcinoma, monitoring therapeutic efficacy, and disclosing disease recurrence. However, alternative methods are been proposed just as the free to total PSA ratio, PSA density, PSA velocity, which could improve the diagnostic sensibility and the specificity. Image diagnostic methods include transrectal ultra sound, computerized tomography, magnetic resonance image, and bone cintigraphy. The ultra sound is the best approach to guide the prostate biopsy and, together with the magnetic resonance is still useful for loco regional graduation. Computerized tomography as magnetic resonance image can be used for identification of linfonodal involvement. Bone cintigraphy is the best method for the identification of metastatic disease. (author)

  10. Technique of infrared synchrotron acceleration diagnostics

    International Nuclear Information System (INIS)

    Mal'tsev, A.A.; Mal'tsev, M.A.

    1997-01-01

    Techniques of measuring of current and geometric parameters and evaluating of energy parameters of the ring bunch of relativistic low-energy electrons have been presented. They have been based on using the synchrotron radiation effect in its infrared spectral part. Fast infrared detectors have provided radiation detection in the spectral range Δλ ≅ 0.3-45 μm. The descriptions of some data monitoring and measuring systems developed in JINR for the realization of techniques of the infrared synchrotron acceleration diagnostics have been given. Infrared optics elements specially developed have been used in these systems

  11. Dental diagnostics using optical coherence techniques

    Energy Technology Data Exchange (ETDEWEB)

    Nathel, H. [Lawrence Livermore National Lab., CA (United States); Colston, B. [Univ. of California, San Francisco, CA (United States); Armitage, G. [Univ. of California, Davis, CA (United States)] [and others

    1994-11-15

    Optical radiation can be used for diagnostic purposes in oral medicine. However, due to the turbid, amorphous, and inhomogeneous nature of dental tissue conventional techniques used to transilluminate materials are not well suited to dental tissues. Optical coherence techniques either in the time- of frequency-domain offer the capabilities of discriminating scattered from unscattered light, thus allowing for imaging through turbid tissue. Currently, using optical time-domain reflectometry we are able to discriminate specular from diffuse reflections occurring at tissue boundaries. We have determined the specular reflectivity of enamel and dentin to be approximately 6.6 x 10{sup -5} and 1.3 x 10{sup -6}, respectively. Implications to periodontal imaging will be discussed.

  12. Current possibilities of chorioretinites diagnostics

    Directory of Open Access Journals (Sweden)

    O. V. Chudinova

    2014-07-01

    Full Text Available Purpose: to study the morphometric changes in retina and the state of regional hemodynamics for chorioretinites of different etiology, to draw parallels between these methods of study with evaluation of their diagnostical significance.Methods: Clinical and instrumental examination was performed in 15 patients (15 eyes — group 1 — with the verified diagnosis of toxoplasmous chorioretinitis and in 13 patients (13 eyes — group 2 — with the diagnosis of tuberculous chorioretinitis. Control (group 3 consisted of 20 subjects (40 eyes, 9 males, 11 females, without any pathology of organ of vision. Complex ophthalmologic examination was performed in all the patients; the examination included the following procedures: determination of visual acuity with correction, computer perimetry, biomicroscopy of eye fundus, inspection of eye fundus using Goldman lens, optic coherent tomogra- phy (OCt, ultrasound Dopplerography (USDG of eye vessels.Results: the following was determined by OCt data: subclinical serous retinal detachment, isolated cells of cyst-like edema, cyst- like edema in macular zone, unevenness of hyperreflective band of pigment epithelium, thinning of neurosensory retina in the area of scarry focus, hyperreflectivity of the zone of the fibrosis being formed, architectonics disorder of NE layers in foveolar zone and para- foveally at the expense of the presence of small hyperreflective parts. In the presence of proliferative process in the vascular coat the reliable decrease of blood flow maximal and minimal velocities in the posterior short ciliary arteries, maximal and minimal velocities of blood flow in the posterior long ciliary arteries in comparison with the values of patients from control group. the data obtained are supposed that proliferative processes in the vascular coat are accompanied by marked local hemodynamic disorders, which should be taken into consideration when complex therapy is prescribed.Conclusion: Dynamic

  13. Novel Nonlinear Laser Diagnostic Techniques

    Science.gov (United States)

    1993-07-01

    a thermometric probe of reactive flows. Since the two-photon pump laser couples a Doppler broadened ground state velocity distribution to the excited...rism, and passed unfocused into an aluminum cell con- in frequency space. Regions for line fitting are found by taining 99% pure NO. The gas mixture...of ASE as a More recently, ASE has prompted interest as an thermometric probe of combustion environments optical diagnostic of combustion environments

  14. Mammography: Technique and diagnostic accuracy

    International Nuclear Information System (INIS)

    Kim, Chung Ja; Bahk, Yong Whee; Lee, Don Young

    1974-01-01

    Mammography is now in world wide use, But this has received rather scanty attention in Korea. The purposes of the present communication are twofold: (1) Detailing of technical and photographic aspects of mam in ography and (2) an assessment of its diagnostic accuracy as experienced by us. The clinical materials consisted of 88 cases of mammography performed at the Department of Radiology, St. Mary's Hospital, Catholic Medical College during the 2 years-period from April 1972. We used nonscreen type mammographic or industrial fine- grain films, and a special mammographic device that can be attached to any of the ordinary radiographic machine. Technical factors are shown in Table II. Of 88 cases 19 were operated on or biopsied. There were 7 cases of carcinoma. 8 cases of inflammatory diseases, and 4 cases of benign tumor. Mammographic diagnosis was correct in 85.7% of carcinoma and 87.5% of inflammatory diseases. One misdiagnosis of 7 cases of carcinoma was turned out to be cystosarcoma phylloides. Of 4 cases of benign tumors 2 were correctly diagnosed, and the other 2 mistaken for either inflammatory disease or simple lactating breast. However, none of the benign conditions were diagnosed as malignant process. We found that nonscreen type mammographic or industrial fine-grain films, and hand-processing were necessary in obtaining the mammograms of desirable quality

  15. Current diagnostic modalities for vulnerable plaque detection

    NARCIS (Netherlands)

    J.A. Schaar (Johannes); F. Mastik (Frits); E.S. Regar (Eveline); C.A. den Uil (Corstiaan); F.J.H. Gijsen (Frank); J.J. Wentzel (Jolanda); P.W.J.C. Serruys (Patrick); A.F.W. van der Steen (Ton)

    2007-01-01

    textabstractRupture of vulnerable plaques is the main cause of acute coronary syndrome and myocardial infarction. Identification of vulnerable plaques is therefore essential to enable the development of treatment modalities to stabilize such plaques. Several diagnostic methods are currently tested

  16. Progress in diagnostic techniques for sc cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    While routinely achieved performance characteristics of superconducting cavities have now reached a level which makes them useful in large scale applications, achieving this level has come only through the knowledge gained by systematic studies of performance limiting phenomena. Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of a few exception examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. Here recent developments in diagnostic techniques are discussed. 18 references, 12 figures

  17. Research and development of an aimed magnetic lead current density-magnetic field diagnostic. Final report

    International Nuclear Information System (INIS)

    1985-01-01

    A diagnostics survey was made to provide a clear definition of advanced diagnostic needs and the limitations of current approaches in addressing those needs. Special attention was given to the adequacy with which current diagnostics are interfaced to signal processing/data acquisition devices and systems. Critical evaluations of selected alternative diagnostic techniques for future R and D activities are presented. The conceptual basis of the Aimed Magnetic Lead Gradiometric system as a current density/magnetic field diagnostic is established

  18. Alternative diagnostic technique for carpal tunnel syndrome

    International Nuclear Information System (INIS)

    Hayakawa, Katsuhiko; Nakane, Takashi; Kobayashi, Shigeru; Shibata, Kunio

    2002-01-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  19. Alternative diagnostic technique for carpal tunnel syndrome

    Energy Technology Data Exchange (ETDEWEB)

    Hayakawa, Katsuhiko; Nakane, Takashi [Aiko Orthopaedic Hospital, Nagoya (Japan); Kobayashi, Shigeru; Shibata, Kunio [Fujita Health Univ., Toyoake, Aichi (Japan). School of Medicine

    2002-10-01

    Compressive and entrapment neuropathies are common clinical syndromes characterized by neurologic deficits due to mechanical or dynamic compression of peripheral nerves. However, the definitive diagnosis based on clinical symptoms alone is difficult in many cases, and the electrophysiological diagnostic method is solely used as a supplementary diagnostic method at present. As a new diagnostic method for entrapment neuropathy, the present study investigated the usefulness of gadolinium-enhanced MRI in carpal tunnel syndrome. On enhanced MRI of idiopathic carpal tunnel syndrome, contrast-enhancement in the median nerve was found in 30 of 34 hands (88.2%). Enhanced MRI allows to visualize intraneural edema in the nerve easily on the naked eye. Therefore, this technique supplied useful information for making definitive diagnosis and is promising as a non-invasive diagnostic method for entrapment neuropathy. (author)

  20. A REVIEW ON DIAGNOSTIC TECHNIQUES FOR BRUCELLOSIS

    African Journals Online (AJOL)

    User

    2014-01-01

    Jan 1, 2014 ... Brucellosis presents with many clinical manifestation that make its diagnosis a difficult task. Ever since the report of the first serologic test for brucellosis, a definitive diagnostic technique has been actively pursued. The most widely used methods of diagnosis are based on serology, which measures the.

  1. Nanorobotics current approaches and techniques

    CERN Document Server

    Ferreira, Antoine

    2013-01-01

    Nanorobot devices now perform a wide variety of tasks at the nanoscale in a wide variety of fields including but not limited to fields such as manufacturing, medicine, supply chain, biology, and outer space. Nanorobotics: Current Approaches and Techniques is a comprehensive overview of this interdisciplinary field with a wide ranging discussion that includes nano-manipulation and industrial nanorobotics, nanorobotics in biology and medicine, nanorobotic sensing, navigation and swarm behavior, and protein and DNA-based nanorobotics. Also included is the latest on topics such as bio-nano-actuators and propulsion and navigation of nanorobotic systems using magnetic fields. Nanorobotics: Current Approaches and Techniques is an ideal book for scientists, researchers, and engineers actively involved in applied and robotic research and development.

  2. Neurocysticercosis: Diagnostic problems & current therapeutic strategies

    Directory of Open Access Journals (Sweden)

    Vedantam Rajshekhar

    2016-01-01

    Full Text Available Neurocysticercosis (NCC is the most common single cause of seizures/epilepsy in India and several other endemic countries throughout the world. It is also the most common parasitic disease of the brain caused by the cestode Taenia solium or pork tapeworm. The diagnosis of NCC and the tapeworm carrier (taeniasis can be relatively inaccessible and expensive for most of the patients. In spite of the introduction of several new immunological tests, neuroimaging remains the main diagnostic test for NCC. The treatment of NCC is also mired in controversy although, there is emerging evidence that albendazole (a cysticidal drug may be beneficial for patients by reducing the number of seizures and hastening the resolution of live cysts. Currently, there are several diagnostic and management issues which remain unresolved. This review will highlight some of these issues.

  3. Neurocysticercosis: Diagnostic problems & current therapeutic strategies

    Science.gov (United States)

    Rajshekhar, Vedantam

    2016-01-01

    Neurocysticercosis (NCC) is the most common single cause of seizures/epilepsy in India and several other endemic countries throughout the world. It is also the most common parasitic disease of the brain caused by the cestode Taenia solium or pork tapeworm. The diagnosis of NCC and the tapeworm carrier (taeniasis) can be relatively inaccessible and expensive for most of the patients. In spite of the introduction of several new immunological tests, neuroimaging remains the main diagnostic test for NCC. The treatment of NCC is also mired in controversy although, there is emerging evidence that albendazole (a cysticidal drug) may be beneficial for patients by reducing the number of seizures and hastening the resolution of live cysts. Currently, there are several diagnostic and management issues which remain unresolved. This review will highlight some of these issues. PMID:28139530

  4. THE CURRENT METHODS FOR MOLECULAR DIAGNOSTICS OF FISH DISEASES (REVIEW

    Directory of Open Access Journals (Sweden)

    O. Zaloilo

    2016-06-01

    Full Text Available Purpose. The methods of molecular diagnostic (MMD gradually become widespread in modern fish farming. MMD contain a wide variety of specific approaches, each of which has distinct limits of their possible applications and is characterized by individual peculiarities in practical performance. In addition to high sensitivity and the possibility of rapid diagnostics, the main advantage of molecular methods is to determine the uncultivated infectious agents. DNA amplification allows identifying pathogenic microorganisms at very small quantities even in the minimum sample volume. Molecular methods of diagnostic enable the determination of infection in latent or acute phases. These methods allow showing the differences between pathogens with similar antigenic structures. The current literature data on this subject usually show a methodology in the narrow context of the tasks or practical results obtained through such approaches. Thus, a synthesis of existing information on the mechanisms of action and the limits of the typical problems of basic methods of molecular diagnostics are an urgent task of fish breeding. In particular, the following description will more effectively choose one or several approaches to identify pathogens in fish. Findings. This paper reviews the basic molecular methods that are used in the world's aquaculture for diagnosis of various diseases in commercial fish species. Originality. This work is a generalization of data on the principles and mechanisms for the implementation of diagnostics based on modern molecular techniques. For each of the mentioned approaches, the most promising areas of application were shown. The information is provided in the form of a comparative analysis of each methodology, indicating positive and negative practical aspects. Practical value. The current review of modern methods of molecular diagnostic in aquaculture is focused on practical application. Generalizing and analytical information can be

  5. Whole Genome Sequencing Increases Molecular Diagnostic Yield Compared with Current Diagnostic Testing for Inherited Retinal Disease.

    Science.gov (United States)

    Ellingford, Jamie M; Barton, Stephanie; Bhaskar, Sanjeev; Williams, Simon G; Sergouniotis, Panagiotis I; O'Sullivan, James; Lamb, Janine A; Perveen, Rahat; Hall, Georgina; Newman, William G; Bishop, Paul N; Roberts, Stephen A; Leach, Rick; Tearle, Rick; Bayliss, Stuart; Ramsden, Simon C; Nemeth, Andrea H; Black, Graeme C M

    2016-05-01

    To compare the efficacy of whole genome sequencing (WGS) with targeted next-generation sequencing (NGS) in the diagnosis of inherited retinal disease (IRD). Case series. A total of 562 patients diagnosed with IRD. We performed a direct comparative analysis of current molecular diagnostics with WGS. We retrospectively reviewed the findings from a diagnostic NGS DNA test for 562 patients with IRD. A subset of 46 of 562 patients (encompassing potential clinical outcomes of diagnostic analysis) also underwent WGS, and we compared mutation detection rates and molecular diagnostic yields. In addition, we compared the sensitivity and specificity of the 2 techniques to identify known single nucleotide variants (SNVs) using 6 control samples with publically available genotype data. Diagnostic yield of genomic testing. Across known disease-causing genes, targeted NGS and WGS achieved similar levels of sensitivity and specificity for SNV detection. However, WGS also identified 14 clinically relevant genetic variants through WGS that had not been identified by NGS diagnostic testing for the 46 individuals with IRD. These variants included large deletions and variants in noncoding regions of the genome. Identification of these variants confirmed a molecular diagnosis of IRD for 11 of the 33 individuals referred for WGS who had not obtained a molecular diagnosis through targeted NGS testing. Weighted estimates, accounting for population structure, suggest that WGS methods could result in an overall 29% (95% confidence interval, 15-45) uplift in diagnostic yield. We show that WGS methods can detect disease-causing genetic variants missed by current NGS diagnostic methodologies for IRD and thereby demonstrate the clinical utility and additional value of WGS. Copyright © 2016 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  6. Submucosal tunneling techniques: current perspectives.

    Science.gov (United States)

    Kobara, Hideki; Mori, Hirohito; Rafiq, Kazi; Fujihara, Shintaro; Nishiyama, Noriko; Ayaki, Maki; Yachida, Tatsuo; Matsunaga, Tae; Tani, Johji; Miyoshi, Hisaaki; Yoneyama, Hirohito; Morishita, Asahiro; Oryu, Makoto; Iwama, Hisakazu; Masaki, Tsutomu

    2014-01-01

    Advances in endoscopic submucosal dissection include a submucosal tunneling technique, involving the introduction of tunnels into the submucosa. These tunnels permit safer offset entry into the peritoneal cavity for natural orifice transluminal endoscopic surgery. Technical advantages include the visual identification of the layers of the gut, blood vessels, and subepithelial tumors. The creation of a mucosal flap that minimizes air and fluid leakage into the extraluminal cavity can enhance the safety and efficacy of surgery. This submucosal tunneling technique was adapted for esophageal myotomy, culminating in its application to patients with achalasia. This method, known as per oral endoscopic myotomy, has opened up the new discipline of submucosal endoscopic surgery. Other clinical applications of the submucosal tunneling technique include its use in the removal of gastrointestinal subepithelial tumors and endomicroscopy for the diagnosis of functional and motility disorders. This review suggests that the submucosal tunneling technique, involving a mucosal safety flap, can have potential values for future endoscopic developments.

  7. Current diagnostic approaches to subarachnoid haemorrhage

    International Nuclear Information System (INIS)

    U-King-Im, Jean Marie; Koo, Brendan; Trivedi, Rikin A.; Higgins, Nicholas J.; Tay, Keng Y.; Cross, Justin J.; Antoun, Nagui M.; Gillard, Jonathan H.

    2005-01-01

    Over the past decade, significant advances have been made in the field of subarachnoid haemorrhage (SAH). Prompt diagnosis with high-resolution CT and intensive critical care support remain key aspects of good patient management. Early identification and definitive treatment of underlying ruptured aneurysms is generally advocated to reduce the risk of re-bleeding, a complication with high mortality and morbidity. Although intra-arterial digital subtraction angiography (DSA) is still considered the gold standard for sourcing aneurysms, CT angiography, especially with the evolution of multi-slice technology, is slowly gaining acceptance as a rapid, accessible and minimally invasive method which appears likely to replace DSA as first-line modality in the future. Furthermore, the advent of Guglielmi detachable coils and the ISAT trial have revolutionised the treatment of ruptured aneurysms, with a significant trend towards endovascular coiling away from operative clipping. Improvements in clinical experience, coiling technology and assistive devices now allow interventionalists to potentially treat the majority of aneurysms, including wide-necked or complex lesions. The uncertain long-term results of coiling, however, still fuel strong debate and controversy. This review summarises current diagnostic approaches to SAH from a radiological perspective, with an emphasis on aneurysmal SAH and an evidence-based approach to the role of imaging and interventional radiology in diagnosis, treatment and follow-up. (orig.)

  8. Current diagnostic approaches to subarachnoid haemorrhage

    Energy Technology Data Exchange (ETDEWEB)

    U-King-Im, Jean Marie; Koo, Brendan; Trivedi, Rikin A.; Higgins, Nicholas J.; Tay, Keng Y.; Cross, Justin J.; Antoun, Nagui M.; Gillard, Jonathan H. [Addenbrooke' s Hospital, University Department of Radiology, Cambridge (United Kingdom)

    2005-06-01

    Over the past decade, significant advances have been made in the field of subarachnoid haemorrhage (SAH). Prompt diagnosis with high-resolution CT and intensive critical care support remain key aspects of good patient management. Early identification and definitive treatment of underlying ruptured aneurysms is generally advocated to reduce the risk of re-bleeding, a complication with high mortality and morbidity. Although intra-arterial digital subtraction angiography (DSA) is still considered the gold standard for sourcing aneurysms, CT angiography, especially with the evolution of multi-slice technology, is slowly gaining acceptance as a rapid, accessible and minimally invasive method which appears likely to replace DSA as first-line modality in the future. Furthermore, the advent of Guglielmi detachable coils and the ISAT trial have revolutionised the treatment of ruptured aneurysms, with a significant trend towards endovascular coiling away from operative clipping. Improvements in clinical experience, coiling technology and assistive devices now allow interventionalists to potentially treat the majority of aneurysms, including wide-necked or complex lesions. The uncertain long-term results of coiling, however, still fuel strong debate and controversy. This review summarises current diagnostic approaches to SAH from a radiological perspective, with an emphasis on aneurysmal SAH and an evidence-based approach to the role of imaging and interventional radiology in diagnosis, treatment and follow-up. (orig.)

  9. Surface CUrrents from a Diagnostic model (SCUD): Pacific

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The SCUD data product is an estimate of upper-ocean velocities computed from a diagnostic model (Surface CUrrents from a Diagnostic model). This model makes daily...

  10. LeRC rail accelerators: test designs and diagnostic techniques

    International Nuclear Information System (INIS)

    Zana, L.M.; Kerslake, W.R.; Sturman, J.C.; Wang, S.Y.; Terdan, F.F.

    1984-01-01

    The feasibility of using rail accelerators for various in-space and to-space propulsion applications was investigated. A 1 meter, 24 sq mm bore accelerator was designed with the goal of demonstrating projectile velocities of 15 km/sec using a peak current of 200 kA. A second rail accelerator, 1 meter long with a 156.25 sq mm bore, was designed with clear polycarbonate sidewalls to permit visual observation of the plasma arc. A study of available diagnostic techniques and their application to the rail accelerator is presented. Specific topics of discussion include the use of interferometry and spectroscopy to examine the plasma armature as well as the use of optical sensors to measure rail displacement during acceleration. Standard diagnostics such as current and voltage measurements are also discussed. 15 references

  11. Noninvasive Diagnostic Technique in Stenotic Coronary Atherosclerosis

    Directory of Open Access Journals (Sweden)

    A. Yu. Vasilyev

    2005-01-01

    Full Text Available Objective: to determine the sensitivity and specificity of combined stress echocardiography (EchoCG using dipyri-damole and dobutamine in diagnosing and defining the extent of stenotic coronary lesions in coronary heart disease (CHD in a group of critically ill patients who are unable to perform a physical exercise.Materials and methods: the study included 57 male patients with suspected acute coronary syndrome who underwent stress EchoCG using dipyridamole in high doses in combination with dobutamine, as well as coronary angiography.Results: stress EchoCG could bring up to the diagnostic criteria in all the patients, of whom 9 patients were found at coronary angiography to have no coronary lesion, 34 and 14 patients had one- and many-vessel lesions, respectively. The sensitivity and specificity of combined stress EchoCG were significantly higher than those of EchoCG used in the diagnosis of CHD.Conclusion: stress EchoCG using dipyridamole in combination with dobutamine is a highly informative safe noninvasive technique for diagnosing CHD, its helps to identify patients with atypical acute coronary syndrome and to form a group of patients to be subject to urgent coronarography and angiosurgical intervention. The pattern of segmental contractile disorders at the height of exercise during combined stress Echo-CG makes it possible to define the site of stenotic coronary atherosclerosis with 97.3% sensitivity and to diagnose many-vessel lesion with 100% sensitivity and 100%specificity.

  12. Restless Legs Syndrome with Current Diagnostic Criteria

    Directory of Open Access Journals (Sweden)

    Meral Bilgilisoy Filiz

    2015-08-01

    Full Text Available Restless legs syndrome (RLS, also known as Willis-Ekbom disease, is a chronic movement disorder, characterized by an urge to move legs usually accompanied by uncomfortable sensations and sleep disorders. The prevalence of the syndrome ranges from 1% to 15% in the general population, and about 2% during childhood. RLS is the most common movement disorder in pregnancy. However RLS still remains underdiagnosed probably due to lack of accurate information about the disease. Family history is positive in 50-70% of the primary RLS patients. The secondary form of the syndrome is associated with iron deficiency, renal failure, pregnancy, diabetes mellitus and many rheumatologic disorders. Secondary forms generally manifest at older ages and have a rapid progression with a poorer prognosis. The pathophysiology of RLS is focused on the dopaminergic system, reduced central nervous system iron levels and genetic linkages. Diagnosis is based on clinical features and the diagnostic criteria suggested by International RLS Study Group. Secondary causes must be carefully investigated before the treatment. In mild forms of the disease non-pharmacologic therapies might be useful, while in moderate or severe forms of the disease generally pharmacologic therapies such as dopamine agonists, anticonvulsants, opioids and benzodiazepines are required. (Turkish Journal of Osteoporosis 2015;21: 87-95

  13. Noise diagnostic: An advanced technique in Cuba

    International Nuclear Information System (INIS)

    Aguilar, O.

    1992-01-01

    This paper examines the main steps of the noise analysis technique implementation in our country from 1988. The review identifies two main areas, improvements of Nuclear Power Plant operational surveillance techniques and non-nuclear industrial applications. Also reported are some of the on going researches programs including projects on noise analysis instrumentation developments at the Higher Institute for Nuclear Sciences and Technology

  14. The Awareness of Health Professionals in Diagnostic Techniques ...

    African Journals Online (AJOL)

    hanumantp

    clear that most reviewed articles used the same conventional methods in ... Knowledge about the possible correlation of occult blood with reasons other than ... diagnostic techniques used in the examination of intestinal parasites in Gaza Strip.

  15. [Advances of Molecular Diagnostic Techniques Application in Clinical Diagnosis.

    Science.gov (United States)

    Ying, Bin-Wu

    2016-11-01

    Over the past 20 years,clinical molecular diagnostic technology has made rapid development,and became the most promising field in clinical laboratory medicine.In particular,with the development of genomics,clinical molecular diagnostic methods will reveal the nature of clinical diseases in a deeper level,thus guiding the clinical diagnosis and treatments.Many molecular diagnostic projects have been routinely applied in clinical works.This paper reviews the advances on application of clinical diagnostic techniques in infectious disease,tumor and genetic disorders,including nucleic acid amplification,biochip,next-generation sequencing,and automation molecular system,and so on.

  16. Essentials of diagnostic and interventional angiographic technique

    International Nuclear Information System (INIS)

    Gerlock, A.J.; Mirfakhraee, M.

    1985-01-01

    This volume presents coverage of basic angiographic techniques and shows how to get to the point of taking the angiogram, and tells how to avoid pitfalls. Particularly valuable is the information on how to get out of trouble if an error is made while manipulating the catheter

  17. Noninvasive Remote Sensing Techniques for Infrastructures Diagnostics

    Directory of Open Access Journals (Sweden)

    Angelo Palombo

    2011-01-01

    Full Text Available The present paper aims at analyzing the potentialities of noninvasive remote sensing techniques used for detecting the conservation status of infrastructures. The applied remote sensing techniques are ground-based microwave radar interferometer and InfraRed Thermography (IRT to study a particular structure planned and made in the framework of the ISTIMES project (funded by the European Commission in the frame of a joint Call “ICT and Security” of the Seventh Framework Programme. To exploit the effectiveness of the high-resolution remote sensing techniques applied we will use the high-frequency thermal camera to measure the structures oscillations by high-frequency analysis and ground-based microwave radar interferometer to measure the dynamic displacement of several points belonging to a large structure. The paper describes the preliminary research results and discusses on the future applicability and techniques developments for integrating high-frequency time series data of the thermal imagery and ground-based microwave radar interferometer data.

  18. Diagnostic techniques in deflagration and detonation studies.

    Science.gov (United States)

    Proud, William G; Williamson, David M; Field, John E; Walley, Stephen M

    2015-12-01

    Advances in experimental, high-speed techniques can be used to explore the processes occurring within energetic materials. This review describes techniques used to study a wide range of processes: hot-spot formation, ignition thresholds, deflagration, sensitivity and finally the detonation process. As this is a wide field the focus will be on small-scale experiments and quantitative studies. It is important that such studies are linked to predictive models, which inform the experimental design process. The stimuli range includes, thermal ignition, drop-weight, Hopkinson Bar and Plate Impact studies. Studies made with inert simulants are also included as these are important in differentiating between reactive response and purely mechanical behaviour.

  19. Mechanical system diagnostics using vibration testing techniques

    Science.gov (United States)

    Mcleod, Catherine D.; Raju, P. K.; Crocker, M. J.

    1990-01-01

    The 'Cepstrum' technique of vibration-path identification allows the recovery of the transfer function of a system with little knowledge as to its excitation force, by means of a mathematical manipulation of the system output in conjunction with subtraction of part of the output and suitable signal processing. An experimental program has been conducted to evaluate the usefulness of this technique in the cases of simple, cantilever-beam and free-free plate structures as well as in that of a complex mechanical system. On the basis of the transfer functions thus recovered, it was possible to evaluate the shifts in the resonance frequencies of a structure due to the presence of defects.

  20. Diagnostic techniques in cerebral artery occlusions

    Energy Technology Data Exchange (ETDEWEB)

    Huber, P

    1972-01-01

    In two-thrids of the cases of cerebral artery occlusions ophthalmodynamotry, thermography, and the fluorescein test are sufficient. In cases where these give insufficient data, scintigraphy is the preferred screening method. For determination of the regional blood flow /sup 133/Xe is used. Angiographic investigation, however, is the method that gives the most clinically valuable data. The techniques used and the risks inherent in the method are described. (JSR)

  1. Elastographic techniques of thyroid gland: current status.

    Science.gov (United States)

    Andrioli, Massimiliano; Persani, Luca

    2014-08-01

    Thyroid nodules are very common with malignancies accounting for about 5 %. Fine-needle biopsy is the most accurate test for thyroid cancer diagnosis. Elastography, a new technology directly evaluating the elastic property of the tissue, has been recently added to the diagnostic armamentarium of the endocrinologists as noninvasive predictor of thyroid malignancy. In this paper, we critically reviewed characteristics and applications of elastographic methods in thyroid gland. Elastographic techniques can be classified on the basis of the following: source-of-tissue compression (free-hand, carotid vibration, ultrasound pulses), processing time (real-time, off-line), stiffness expression (qualitative, semi-quantitative, or quantitative). Acoustic radiation force impulse and aixplorer shear wave are the newest and most promising quantitative elastographic methods. Primary application of elastography is the detection of nodular lesions suspicious for malignancy. Published data show a high sensitivity and negative predictive value of the technique. Insufficient data are available on the possible application of elastography in the differential diagnosis of indeterminate lesions and in thyroiditis. Elastography represents a noninvasive tool able to increase the performance of ultrasound in the selection of thyroid nodules at higher risk of malignancy. Some technical improvements and definition of more robust quantitative diagnostic criteria are required for assigning a definite role in the management of thyroid nodules and thyroiditis to elastography.

  2. Current profile reconstruction using electron temperature imaging diagnostics

    International Nuclear Information System (INIS)

    Tritz, K.; Stutman, D.; Delgado-Aparicio, L.F.; Finkenthal, M.; Pacella, D.; Kaita, R.; Stratton, B.; Sabbagh, S.

    2004-01-01

    Flux surface shape information can be used to constrain the current profile for reconstruction of the plasma equilibrium. One method of inferring flux surface shape relies on plasma x-ray emission; however, deviations from the flux surfaces due to impurity and density asymmetries complicate the interpretation. Electron isotherm surfaces should correspond well to the plasma flux surfaces, and equilibrium constraint modeling using this isotherm information constrains the current profile. The KFIT code is used to assess the profile uncertainty and to optimize the number, location and SNR required for the Te detectors. As Te imaging detectors we consider tangentially viewing, vertically spaced, linear gas electron multiplier arrays operated in pulse height analysis (PHA) mode and multifoil soft x-ray arrays. Isoflux coordinate sets provided by T e measurements offer a strong constraint on the equilibrium reconstruction in both a stacked horizontal array configuration and a crossed horizontal and vertical beam system, with q 0 determined to within ±4%. The required SNR can be provided with either PHA or multicolor diagnostic techniques, though the multicolor system requires ∼x4 better statistics for comparable final errors

  3. Oncologic applications of diagnostic imaging techniques

    International Nuclear Information System (INIS)

    Forrest, L.J.; Thrall, D.E.

    1995-01-01

    Before appropriate therapy can be instituted for a cancer patient, the presence and extent of tumor must be evaluated. Deciding which imaging technique to use depends on tumor location, type, and biologic behavior. Conventional radiography provides important information at a relatively low cost compared with other imaging modalities. Ultrasound is a valuable adjunct to radiography, but does not replace it because both imaging modalities provide unique information. Nuclear medicine procedures contribute additional, unique data by providing physiological information, but specificity is lacking. Both CT and MRI provide images with exquisite anatomic detail, but availability and cost prohibit their general use

  4. Diagnostic development for current density profile control at KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J., E-mail: jinseok@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); University of Science and Technology, Daejeon 34113 (Korea, Republic of); Chung, J. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Messmer, M.C.C. [Department of Applied Physics, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-11-01

    Highlights: • The motional Stark effect (MSE) diagnostic installed at KSTAR. • Engineering challenges and solutions on the design and fabrication of the front optics housing and filter modules. • Characterization of the bandpass filters and the responses to polarized light. - Abstract: The current density profile diagnostics are critical for the control of the steady-state burning plasma operations. A multi-channel motional Stark effect (MSE) diagnostic system has been implemented for the measurements of the internal magnetic field structures that constrain the magnetic equilibrium reconstruction to accurately produce the tokamak safety factor and current density profiles for the Korea Superconducting Tokamak Advanced Research (KSTAR). This work presents the design and fabrication of the front optics and the filter modules and the calibration activities for the MSE diagnostic at KSTAR.

  5. Some novel diagnostic techniques for plasma chemistry

    International Nuclear Information System (INIS)

    Kaufman, M.

    1976-01-01

    In order to probe the mechanisms of chemical transformations in electric discharges it is most useful to monitor concentrations of reactants, products and reactive intermediates as a function of discharge parameters. Mass spectrometry, a popular technique for observing intermediates in chemical reactions, meets with particular difficulty when applied to discharges, due to the presence of excited molecules as well as free radicals in such systems. Molecular beam analysis, a synthesis of mass spectrometry with molecular beam measurements of electric and magnetic moments and velocity distributions, is a technique developed in the laboratory which offers distinct advantages for the analysis of intermediates in electric discharges. In low pressure discharges, end-product analysis can be facilitated by sample compression. A chromatographic sampling system which employs compression in order to achieve sensitivity has been developed and evaluated. There is some question concerning the appropriate discharge parameters to be employed in correlating measured variations in concentrations. An investigation is being made of the use of discharge 'actinometers' as a means of measuring the intensity of electric discharges. In discharges the intensity (number and energy of the electrons) and the chemistry are strongly coupled. Thus, it is necessary that the actinometer be present in the reactor; it is not permissible to substitute vessels as is customary in photochemical investigations. Since the actinometer is to measure only the discharge intensity, it must not participate in any chemical reactions with molecules and intermediates in the discharge. Finally, the ratio of the rates of the primary interactions of the actinometer and reactant with the discharge must be independent of discharge parameters. (author)

  6. Medical X-ray techniques in diagnostic radiography. 4. ed.

    International Nuclear Information System (INIS)

    Plaats, G.J. van der; Vijlbrief, P.

    1980-01-01

    A step by step account is given of every aspect of the technical factors involved in the production of X-ray images. Chapter titles include, methods of image formation and laws of projection, sharpness and unsharpness, contrast, perceptibility of detail in the radiographic image-image quality, properties of fluoroscopic screens, radiographic films, intensifying screens and cassettes, image intensification and X-ray television, processing technique, fluoroscopy and radiographic technique in general, special radiographic techniques, radiographic examinations using contrast media, exposure and exposure tables and automatic density control, diagnostic X-ray apparatus, and diagnostic stands and accessories. (C.F.)

  7. Compensation techniques for operational amplifier bias current

    International Nuclear Information System (INIS)

    Silva, M.S.

    1981-01-01

    Two techniques are proposed for the compensation of the input current on operational amplifiers that can be used on inverting and non-inverting configurations. A qualitative analysis of temperature drift problems is made, and as a practical application, the construction of a voltage follower for high impedance measurements is presented. (Author) [pt

  8. The Positron Emission Tomography. A diagnostic technique

    International Nuclear Information System (INIS)

    Salvadori, P.

    2001-01-01

    Positron Emission Tomography (PET) is a new imaging modality, which is able to assess non-invasively the biochemical mechanisms, underlying physiological and pathophysiological processes in vivo in humans. The technique relies on the administration of radioactive tracers labeled with short-lived positron emitters, which need to be produced on site via a particle accelerator (cyclotron). Radionuclides are produced upon request and formulated into biologically active organic molecules having precise pharmacokinetics and specificity. The radiotracer can be detected by the PET scanner and represented as tomographic sections (images of body sections) showing its regional distribution and concentration. This makes it possible to address clinical questions concerning occurrence and evolution of many diseases as well as their response to therapy. The ability to image (measure) biological processes and not only anatomy enables PET to explore diseases in the very early stage, including those diseases which are not related to modifications of organ structure (e.g. psychiatric diseases, metabolic disorders, biochemical disfunction). PET plays a major role, in conjunction with the other imaging modalities, to improve diagnosis capabilities and disease mechanism understanding [it

  9. Laser-based techniques for combustion diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Georgiev, N.

    1997-04-01

    Two-photon-induced Degenerate Four-Wave Mixing, DFWM, was applied for the first time to the detection of CO, and NH{sub 3} molecules. Measurements were performed in a cell, and in atmospheric-pressure flames. In the cell measurements, the signal dependence on the pressure and on the laser beam intensity was studied. The possibility of simultaneous detection of NH{sub 3} and OH was investigated. Carbon monoxide and ammonia were also detected employing two-photon-induced Polarization Spectroscopy, PS. In the measurements performed in a cold gas flow, the signal strength dependence on the laser intensity, and on the polarization of the pump beam, was investigated. An approach to improve the spatial resolution of the Amplified Stimulated Emission, ASE, was developed. In this approach, two laser beams at different frequencies were crossed in the sample. If the sum of the frequencies of the two laser beams matches a two photon resonance of the investigated species, only the molecules in the intersection volume will be excited. NH{sub 3} molecules and C atoms were studied. The potential of using two-photon LIF for two-dimensional imaging of combustion species was investigated. Although LIF is species specific, several species can be detected simultaneously by utilizing spectral coincidences. Combining one- and two-photon process, OH, NO, and O were detected simultaneously, as well as OH, NO, and NH{sub 3}. Collisional quenching is the major source of uncertainty in quantitative applications of LIF. A technique for two-dimensional, absolute species concentration measurements, circumventing the problems associated with collisional quenching, was developed. By applying simple mathematics to the ratio of two LIF signals generated from two counterpropagating laser beams, the absolute species concentration could be obtained. 41 refs

  10. Current trends in molecular diagnostics of chronic myeloid leukemia.

    Science.gov (United States)

    Vinhas, Raquel; Cordeiro, Milton; Pedrosa, Pedro; Fernandes, Alexandra R; Baptista, Pedro V

    2017-08-01

    Nearly 1.5 million people worldwide suffer from chronic myeloid leukemia (CML), characterized by the genetic translocation t(9;22)(q34;q11.2), involving the fusion of the Abelson oncogene (ABL1) with the breakpoint cluster region (BCR) gene. Early onset diagnosis coupled to current therapeutics allow for a treatment success rate of 90, which has focused research on the development of novel diagnostics approaches. In this review, we present a critical perspective on current strategies for CML diagnostics, comparing to gold standard methodologies and with an eye on the future trends on nanotheranostics.

  11. In-vitro diagnostic devices introduction to current point-of-care diagnostic devices

    CERN Document Server

    Cheng, Chao-Min; Chen, Chien-Fu

    2016-01-01

    Addressing the origin, current status, and future development of point-of-care diagnostics, and serving to integrate knowledge and tools from Analytical Chemistry, Bioengineering, Biomaterials, and Nanotechnology, this book focusses on addressing the collective and combined needs of industry and academia (including medical schools) to effectively conduct interdisciplinary research. In addition to summarizing and detailing developed diagnostic devices, this book will attempt to point out the possible future trends of development for point-of-care diagnostics using both scientifically based research and practical engineering needs with the aim to help novices comprehensively understand the development of point-of-care diagnostics. This includes demonstrating several common but critical principles and mechanisms used in point-of-care diagnostics that address practical needs (e.g., disease or healthcare monitoring) using two well-developed examples so far: 1) blood glucose meters (via electrochemistry); and, 2) p...

  12. Development of process diagnostic techniques for piping and equipment

    International Nuclear Information System (INIS)

    Yotsutsuji, Mitoshi

    1987-01-01

    The thing required for using the facilities composing a plant for a long period without anxiety is to quantitatively grasp the quantities of the present condition of the facilities and to take the necessary measures beforehand. For this purpose, the diagnostic techniques for quickly and accurately detect the quantities of the condition of facilities are necessary, and the development of process diagnostic techniques has been desired. The process diagnostic techniques mentioned here mean those for diagnosing the contamination, clogging and performance of towers, tanks, heat exchangers and others. Idemitsu Engineering Co. had developed a simplified diagnostic equipment for detecting the state of fouling in piping in 1982, which is the gamma ray transmission diagnosis named Scale Checker. By further improving it, the process diagnostic techniques for piping and equipment were developed. In this report, the course of development and examination, the principle of detection, the constitution and the examination of remodeling of the Scale Checker are reported. As the cases of process diagnosis in plant facilities, the diagnosis of the clogging in process piping and the diagnosis of the performance of a distillation tower were carried out. The contents of the diagnosis and the results of those cases are explained. (Kako, I.)

  13. Effectiveness of relaxation techniques before diagnostic screening of cancer patients

    Directory of Open Access Journals (Sweden)

    Montserrat Aiger

    2016-07-01

    Full Text Available Psychophysiological arousal was observed in cancer patients during the application of relaxation techniques prior to a diagnostic scan (PET-CT. The aim of the study is twofold: firstly, it is sought to establish whether such techniques can minimize patient arousal before diagnostic screening begins, and secondly to measure which of them are most effective. The dependent variable is electrodermal activity, recording the attentional level and emotional response, and the independent variable comprises the relaxation techniques used, namely Jacobson, breathing and visualization. The 39 patients were split into experimental groups to whom the relaxation techniques (Jacobson, breathing exercises, and visualization were applied before they went for the PET-CT. An activity-module procedure was applied to track electrodermal activity during the relaxation sessions, consisting of instructions, timeout; wait, task; relaxation and end of the recording session. The control group received no relaxation techniques before the PET-CT. Session-end results show that patients who perform relaxation techniques achieve greater attentional focus using Jacobson's technique (M = .212 and enhanced emotional containment using visualization (M = .206. It is concluded that relaxation techniques minimize the state of activation during the waiting period before a diagnostic scan.

  14. Electroencephalography as a diagnostic technique for canine neurological diseases

    Directory of Open Access Journals (Sweden)

    Wrzosek Marcin

    2016-06-01

    Full Text Available Electroencephalography (EEG is a non-invasive examination method for the assessment of functional central nervous system (CNS disturbances. In human medicine it has a special importance as a diagnostic tool for epilepsy. Although many studies were done on the use of EEG for diagnostics of canine central nervous system disorders, the technique is still not applied routinely. The purpose of this paper was to review the use of the electroencephalography in canine neurological disorders of central nervous system diagnosis and assess the future perspectives of this technique in veterinary medicine.

  15. Three dimensional imaging technique for laser-plasma diagnostics

    International Nuclear Information System (INIS)

    Jiang Shaoen; Zheng Zhijian; Liu Zhongli

    2001-01-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments

  16. Three dimensional imaging technique for laser-plasma diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Shaoen, Jiang; Zhijian, Zheng; Zhongli, Liu [China Academy of Engineering Physics, Chengdu (China)

    2001-04-01

    A CT technique for laser-plasma diagnostic and a three-dimensional (3D) image reconstruction program (CT3D) have been developed. The 3D images of the laser-plasma are reconstructed by using a multiplication algebraic reconstruction technique (MART) from five pinhole camera images obtained along different sight directions. The technique has been used to measure the three-dimensional distribution of X-ray of laser-plasma experiments in Xingguang II device, and the good results are obtained. This shows that a CT technique can be applied to ICF experiments.

  17. A new techniques in the physics of diagnostic radiology

    International Nuclear Information System (INIS)

    Jennings, R.J.

    1987-01-01

    The basic physics involved in the generation of X-rays and in the energy dependence of their interaction with matter are reviewed. Some applications of those ideas in both conventional X-ray imaging and in new imaging techniques are studied. Methods for the optimization of X-ray diagnostic imaging system are discussed. (M.A.C.) [pt

  18. Diagnostic techniques used in controlled thermonuclear research at Harwell

    Energy Technology Data Exchange (ETDEWEB)

    Harding, G N; Dellis, A N; Gibson, A; Jones, B; Lees, D J; McWhirter, R W.P.; Ramsden, S A; Ward, S [UK Atomic Energy Authority, AERE, Harwell (United Kingdom)

    1958-07-01

    This paper is a general survey of the lines along which diagnostic methods (spectroscopy, electrical measurements, and the study of high energy radiations) are developing at Harwell, and indicates the results which have been obtained so far. Many of the techniques are in a rudimentary state, and most of the Zeta experiments are incomplete.

  19. Machine monitoring via current signature analysis techniques

    International Nuclear Information System (INIS)

    Smith, S.F.; Castleberry, K.N.; Nowlin, C.H.

    1992-01-01

    A significant need in the effort to provide increased production quality is to provide improved plant equipment monitoring capabilities. Unfortunately, in today's tight economy, even such monitoring instrumentation must be implemented in a recognizably cost effective manner. By analyzing the electric current drawn by motors, actuator, and other line-powered industrial equipment, significant insights into the operations of the movers, driven equipment, and even the power source can be obtained. The generic term 'current signature analysis' (CSA) has been coined to describe several techniques for extracting useful equipment or process monitoring information from the electrical power feed system. A patented method developed at Oak Ridge National Laboratory is described which recognizes the presence of line-current modulation produced by motors and actuators driving varying loads. The in-situ application of applicable linear demodulation techniques to the analysis of numerous motor-driven systems is also discussed. The use of high-quality amplitude and angle-demodulation circuitry has permitted remote status monitoring of several types of medium and high-power gas compressors in (US DOE facilities) driven by 3-phase induction motors rated from 100 to 3,500 hp, both with and without intervening speed increasers. Flow characteristics of the compressors, including various forms of abnormal behavior such as surging and rotating stall, produce at the output of the specialized detectors specific time and frequency signatures which can be easily identified for monitoring, control, and fault-prevention purposes. The resultant data are similar in form to information obtained via standard vibration-sensing techniques and can be analyzed using essentially identical methods. In addition, other machinery such as refrigeration compressors, brine pumps, vacuum pumps, fans, and electric motors have been characterized

  20. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension

    International Nuclear Information System (INIS)

    Eisenberg, B.M.; Linss, G.

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.) [de

  1. Progress in diagnostic techniques for SC [superconducting] cavities

    International Nuclear Information System (INIS)

    Reece, C.E.

    1988-01-01

    Despite the very real progress that has been made, the routine performance of superconducting cavities still falls far short of both the theoretical expectations and the performance of afew exceptional examples. It is the task of systematically applied diagnostic techniques to reveal additional information concerning the response of superconducting surfaces to applied RF fields. In this paper we will direct our attention to discussions of recent developments in diagnostic techniqeus, such as thermometry in superfluid helium, and scanning laser acoustic microscopy. 18 refs., 12 figs

  2. Review of Physicochemical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Janvier Sylvestre N’cho

    2016-05-01

    Full Text Available A power transformer outage has a dramatic financial consequence not only for electric power systems utilities but also for interconnected customers. The service reliability of this important asset largely depends upon the condition of the oil-paper insulation. Therefore, by keeping the qualities of oil-paper insulation system in pristine condition, the maintenance planners can reduce the decline rate of internal faults. Accurate diagnostic methods for analyzing the condition of transformers are therefore essential. Currently, there are various electrical and physicochemical diagnostic techniques available for insulation condition monitoring of power transformers. This paper is aimed at the description, analysis and interpretation of modern physicochemical diagnostics techniques for assessing insulation condition in aged transformers. Since fields and laboratory experiences have shown that transformer oil contains about 70% of diagnostic information, the physicochemical analyses of oil samples can therefore be extremely useful in monitoring the condition of power transformers.

  3. Textbook of focusing techniques in diagnostic radiography. 5. new rev. ed.

    International Nuclear Information System (INIS)

    Bosnjakovic-Buescher, S.; Riegler-Bubeck, C.; Zimmer-Brossy, M.; Bast, B.

    1998-01-01

    This 5th edition of the standard work on focusing techniques in diagnostic radiography is a guide for X-ray medical technicians and radiologists wishing to optimize their skills and produce images of high technical standard and diagnostic value. The major part of the textbook deals with the focusing and imaging techniques for evaluation of the skeleton and inner body organs. The new edition includes the current legal provisions for radiological protection and the latest quality assurance legislation. It is an indispensable source of reference for clinical departments, radiographic practice, and training institutions. (orig./CB) [de

  4. Using Pattern Classification and Recognition Techniques for Diagnostic and Prediction

    Directory of Open Access Journals (Sweden)

    MORARIU, N.

    2007-04-01

    Full Text Available The paper presents some aspects regarding the joint use of classification and recognition techniques for the activity evolution diagnostication and prediction by means of a set of indexes. Starting from the indexes set there is defined a measure on the patterns set, measure representing a scalar value that characterizes the activity analyzed at each time moment. A pattern is defined by the values of the indexes set at a given time. Over the classes set obtained by means of the classification and recognition techniques is defined a relation that allows the representation of the evolution from negative evolution towards positive evolution. For the diagnostication and prediction the following tools are used: pattern recognition and multilayer perceptron. The data set used in experiments describes the pollution due to CO2 emission from the consumption of fuels in Europe. The paper also presents the REFORME software written by the authors and the results of the experiment obtained with this software.

  5. A clinicopathological study of various oral cancer diagnostic techniques

    Directory of Open Access Journals (Sweden)

    G Ulaganathan

    2017-01-01

    Full Text Available Oral cancer is one of the most commonly occurring malignant tumors in the head and neck regions with high incident rate and mortality rate in the developed countries than in the developing countries. Generally, the survival rate of cancer patients may increase when diagnosed at early stage, followed by prompt treatment and therapy. Recently, cancer diagnosis and therapy design for a specific cancer patient have been performed with the advanced computer-aided techniques. The responses of the cancer therapy could be continuously monitored to ensure the effectiveness of the treatment process that hardly requires diagnostic result as quick as possible to improve the quality and patient care. This paper gives an overview of oral cancer occurrence, different types, and various diagnostic techniques. In addition, a brief introduction is given to various stages of immunoanalysis including tissue image preparation, whole slide imaging, and microscopic image analysis.

  6. Fusion alpha loss diagnostic for ITER using activation technique

    Czech Academy of Sciences Publication Activity Database

    Bonheure, G.; Hult, M.; González de Orduña, R.; Vermaercke, P.; Murari, A.; Popovichev, S.; Mlynář, Jan

    2011-01-01

    Roč. 86, 6-8 (2011), s. 1298-1301 ISSN 0920-3796. [Symposium on Fusion Technology (SOFT) /26th./. Port o, 27.09.2010-01.10.2010] Institutional research plan: CEZ:AV0Z20430508 Keywords : ITER * fusion product * burning plasma diagnostics * alpha losses * activation technique Subject RIV: BL - Plasma and Gas Discharge Physics Impact factor: 1.490, year: 2011 http://www.sciencedirect.com/science/article/pii/S0920379611002778

  7. Diagnostic imaging, a 'parallel' discipline. Can current technology provide a reliable digital diagnostic radiology department

    International Nuclear Information System (INIS)

    Moore, C.J.; Eddleston, B.

    1985-01-01

    Only recently has any detailed criticism been voiced about the practicalities of the introduction of generalised, digital, imaging complexes in diagnostic radiology. Although attendant technological problems are highlighted the authors argue that the fundamental causes of current difficulties are not in the generation but in the processing, filing and subsequent retrieval for display of digital image records. In the real world, looking at images is a parallel process of some complexity and so it is perhaps untimely to expect versatile handling of vast image data bases by existing computer hardware and software which, by their current nature, perform tasks serially. (author)

  8. Current diagnostic procedures for diagnosing vertigo and dizziness

    Science.gov (United States)

    Walther, Leif Erik

    2017-01-01

    Vertigo is a multisensory syndrome that otolaryngologists are confronted with every day. With regard to the complex functions of the sense of orientation, vertigo is considered today as a disorder of the sense of direction, a disturbed spatial perception of the body. Beside the frequent classical syndromes for which vertigo is the leading symptom (e.g. positional vertigo, vestibular neuritis, Menière’s disease), vertigo may occur as main or accompanying symptom of a multitude of ENT-related diseases involving the inner ear. It also concerns for example acute and chronic viral or bacterial infections of the ear with serous or bacterial labyrinthitis, disorders due to injury (e.g. barotrauma, fracture of the oto-base, contusion of the labyrinth), chronic-inflammatory bone processes as well as inner ear affections in the perioperative course. In the last years, diagnostics of vertigo have experienced a paradigm shift due to new diagnostic possibilities. In the diagnostics of emergency cases, peripheral and central disorders of vertigo (acute vestibular syndrome) may be differentiated with simple algorithms. The introduction of modern vestibular test procedures (video head impulse test, vestibular evoked myogenic potentials) in the clinical practice led to new diagnostic options that for the first time allow a complex objective assessment of all components of the vestibular organ with relatively low effort. Combined with established methods, a frequency-specific assessment of the function of vestibular reflexes is possible. New classifications allow a clinically better differentiation of vertigo syndromes. Modern radiological procedures such as for example intratympanic gadolinium application for Menière’s disease with visualization of an endolymphatic hydrops also influence current medical standards. Recent methodical developments significantly contributed to the possibilities that nowadays vertigo can be better and more quickly clarified in particular in

  9. Imaging mammary diagnostics. Diagnostic techniques, archetypical findings, differential diagnostcs and interventions. 2. rev. and enl. ed.

    International Nuclear Information System (INIS)

    Heywang-Koebrunner, S.; Schreer, I.

    2008-01-01

    The book includes the following chapters: I. Methodology: anamnesis and interview; clinical evidence, mammography, sonography, magnetic resonance tomography, new imaging techniques (scintigraphy, PET), transcutaneous biopsy, pre-operative marking; II. phenotypes: normal mammary glands, mastopathics, cysts, benign tumors, inflammatory diseases, in-situ carcinomas, invasive carcinomas, lymphomas, other semi-malign and malign tumors, post-traumatic, post-surgical and post-therapeutic changes, skin changes, male mamma, screening, continuative diagnostics of screening evidence and problem solving for symptomatic patients

  10. High current density ion beam measurement techniques

    International Nuclear Information System (INIS)

    Ko, W.C.; Sawatzky, E.

    1976-01-01

    High ion beam current measurements are difficult due to the presence of the secondary particles and beam neutralization. For long Faraday cages, true current can be obtained only by negative bias on the target and by summing the cage wall and target currents; otherwise, the beam will be greatly distorted. For short Faraday cages, a combination of small magnetic field and the negative target bias results in correct beam current. Either component alone does not give true current

  11. Gestational Diabetes Mellitus: a review of current diagnostic strategies concepts

    Directory of Open Access Journals (Sweden)

    Juan Sebastián Frías-Ordoñez

    2016-10-01

    Full Text Available Gestational diabetes mellitus (GDM is a state of carbohydrate intolerance that is first recognized during pregnancy. The initial criteria for diagnosis were established more than 50 years ago by O’Sullivan & Mahan, and since then, some modifications have been made. Currently, diagnosis considers two methods: the onestep approach, consisting of an oral glucose tolerance test (OGTT for 2 hours with 75g of glucose, and the two-step approach, which involves an initial screening test with 50g of glucose and OGTT with 100g of glucose if screening is positive. Both diagnostic approaches have been justified by expert consensus; however, an absolute concept about the method to be applied has not been established yet. To select a method, the clinician must take into account various factors. This paper proposes a historical overview and the presentation of the current status of GDM diagnosis.

  12. Current and Emerging Legionella Diagnostics for Laboratory and Outbreak Investigations

    Science.gov (United States)

    Mercante, Jeffrey W.

    2015-01-01

    SUMMARY Legionnaires' disease (LD) is an often severe and potentially fatal form of bacterial pneumonia caused by an extensive list of Legionella species. These ubiquitous freshwater and soil inhabitants cause human respiratory disease when amplified in man-made water or cooling systems and their aerosols expose a susceptible population. Treatment of sporadic cases and rapid control of LD outbreaks benefit from swift diagnosis in concert with discriminatory bacterial typing for immediate epidemiological responses. Traditional culture and serology were instrumental in describing disease incidence early in its history; currently, diagnosis of LD relies almost solely on the urinary antigen test, which captures only the dominant species and serogroup, Legionella pneumophila serogroup 1 (Lp1). This has created a diagnostic “blind spot” for LD caused by non-Lp1 strains. This review focuses on historic, current, and emerging technologies that hold promise for increasing LD diagnostic efficiency and detection rates as part of a coherent testing regimen. The importance of cooperation between epidemiologists and laboratorians for a rapid outbreak response is also illustrated in field investigations conducted by the CDC with state and local authorities. Finally, challenges facing health care professionals, building managers, and the public health community in combating LD are highlighted, and potential solutions are discussed. PMID:25567224

  13. Diagnostic accuracy of new imaging techniques in breast diseases

    Energy Technology Data Exchange (ETDEWEB)

    Gordenne, W; Bauduin, E [Liege Univ. (Belgium)

    1989-01-01

    During the last decade, the hypothetical carcinogenic effects of mammography have lead to new technical developments in X-ray diagnosis and to use of other imaging techniques such as ultrasonography (US), transillumination, magnetic resonance imaging (MRI). Many preliminary studies were published but few clinical trials are really convincing. According to the definition of a diagnostic tool, none of these new modalities is supposed to supplant mammography in the diagnosis of breast cancer. Improvements are expected by digital mammography in the near future. (Authors).

  14. Current Status on Stress Diagnostic Kit and Detection Technology

    International Nuclear Information System (INIS)

    Park, Sang Hyun; Choi, Mi Hee; Ko, Kyong Cheol

    2008-06-01

    The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases like hypochondria and hypertension. Majority of the human population is exposed to stress in one way or another and hence developing a convenient stress diagnosis kit will be of great use to all. This stress diagnostic kit and detection technology dose not involve simple a mechanical measurement or questionnaires, but is based on developing a detection kit with a high sensitivity, which will mean an easy use for common man. Individuals can undergo regular check ups and can personally diagnose their present situation of health by determining their stress levels, thus enabling them to diagnose the early onset of several stress disorders. This might help them take precautionary measures and thereby lead to a healthy life

  15. Current Status on Stress Diagnostic Kit and Detection Technology

    Energy Technology Data Exchange (ETDEWEB)

    Park, Sang Hyun; Choi, Mi Hee; Ko, Kyong Cheol

    2008-06-15

    The accurate measurement of a stress level is one of the most important issues in a stress diagnosis and its measurement could be of great value in clinical medicine. Stress has a potent effect on the spirit and physical condition of an individual. There are various methods available for its measurement. Some of the commonly used techniques for the diagnosis of a stress level include analysis of the body fluids, questionnaire assessments, psychophysiological evaluations and by determining heart rate variability (HRV) of subjects. However, the existing diagnostic methods have several defects like, a low sensitivity, inaccuracy and long of operation time. In this report, we present a diagnostic technology to detect a stress level which is the origin of various diseases. This method can be of great help in providing an early diagnosis through a biosensor and might play a vital role in preventing diseases like hypochondria and hypertension. Majority of the human population is exposed to stress in one way or another and hence developing a convenient stress diagnosis kit will be of great use to all. This stress diagnostic kit and detection technology dose not involve simple a mechanical measurement or questionnaires, but is based on developing a detection kit with a high sensitivity, which will mean an easy use for common man. Individuals can undergo regular check ups and can personally diagnose their present situation of health by determining their stress levels, thus enabling them to diagnose the early onset of several stress disorders. This might help them take precautionary measures and thereby lead to a healthy life.

  16. Improvement of Railroad Roller Bearing Test Procedures & Development of Roller Bearing Diagnostic Techniques. Volume 2.

    Science.gov (United States)

    1982-04-01

    A comprehensive review of existing basic diagnostic techniques applicable to the railcar roller bearing defect and failure problem was made. Of the potentially feasible diagnostic techniques identified, high frequency vibration was selected for exper...

  17. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    NARCIS (Netherlands)

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map

  18. [Current options of preimplantion genetic screening and preimplantation genetic diagnostics].

    Science.gov (United States)

    Šimečková, V

    The aim of this work is to summarize the current knowledge about preimplantation genetic screening and diagnostics. A review article. Department of Gynecology and Obstetrics, District Hospital Šternberk, IVF Clinic, Olomouc. Preimplantation genetic testing is a complex of genetic and molecular cytogenetic examinations, which can help to detect abnormalities in embryos before transfer into the uterus of the mother. These specialized examinations are based on the latest findings in genetics and assisted reproduction. The preimplantation genetic testing is necessarily associated with a method of in vitro fertilization. It is performed on isolated blastomeres on the third day of embryo cultivation. Nowadays, it is preferred trophectoderm examination of cells from the five-day blastocysts. Generally speaking, after preimplantation genetic testing, we can select only embryos without genetic load to transfer into uterus. Preimplantation genetic testing is an important part of treatment of infertility. Complex diagnostics and treatment of infertile couples are increasingly influenced by the development and use of advanced genomic technologies. Further development and application of these modern methods require close cooperation between the field of assisted reproduction and clinical genetics.

  19. Evidence for current diagnostic criteria of diabetes mellitus

    Institute of Scientific and Technical Information of China (English)

    Ritesh; Kumar[1; Lakshmana; Perumal; Nandhini[1; Sadishkumar; Kamalanathan[1; Jayaprakash; Sahoo[1; Muthupillai; Vivekanadan[1

    2016-01-01

    Diabetes mellitus is a non-communicable metabolic derangement afflicting several millions of individuals globally. It is associated with several micro and macrovascular complications and is also a leading cause of mortality. The unresolved issue is that of definition of the diagnostic threshold for diabetes. The World Health Organization and the American Diabetes Association (ADA) have laid down several diagnostic criteria for diagnosing diabetes and prediabetes based on the accumulating body of evidence.This review has attempted to analyse the scientific evidence supporting the justification of these differing criteria. The evidence for diagnosing diabetes is strong, and there is a concordance between the two professional bodies.The controversy arises when describing the normal lower limit of fasting plasma glucose (FPG) with little evidence favouring the reduction of the FPG by the ADA. Several studies have also shown the development of complications specific for diabetes in patients with prediabetes as defined by the current criteria though there is a significant overlap of such prevalence in individuals with normoglycemia. Large multinational longitudinal prospective studies involving subjects without diabetes and retinopathy at baseline will ideally help identify the threshold of glycemic measurements for future development of diabetes and its complications.

  20. Experience with on-line diagnostics for bushings and current transformers

    Energy Technology Data Exchange (ETDEWEB)

    Brusetti, R.

    2004-02-01

    The application of on-line diagnostic techniques is advocated as an alternative, under certain conditions, for the conventional off-line power factor test used to evaluate the condition of bushings and current transformers. Bushings which are tied to critical system apparatus or which cannot be readily removed from service are considered to be excellent candidates for on-line diagnostics. A case history involving 138-KV bushings is used to demonstrate the value of the on-line diagnostic system which, by taking into account power factor capacitance values along with the rate of change, not only detected the high power factor associated with the bushings, but allowed the high power factor bushings to continue operating with a known problem for over a year. With conventional testing, bushings that exhibited this level of power factor would typically be removed from service. 4 refs., 3 figs.

  1. Control systems for ITER diagnostics, heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Simrock, Stefan, E-mail: stefan.simrock@iter.org

    2016-11-15

    The ITER Diagnostic, Heating and Current Drive systems might appear, on the face of it, to have very different control requirements. There are approximately 45 diagnostic systems, including magnetic sensors for plasma position and shape determination, imaging systems in the IR and visible, Thompson scattering for electron temperature and density, neutron detectors and collective scattering for alpha particle density and energy distribution. The H&CD systems encompass Electron Cyclotron Heating, using 24 1MW, 170 GHz gyrotrons and 5 steerable launchers to deliver 20 MW to the plasma, Ion Cyclotron Heating, using 8 3MW, 40–55 MHz sources and two multi-element launchers to deliver 20 MW to the plasma, and 2 Negative Ion Neutral Beam Injectors, each of which can deliver up to 16.5 MW of 1 MeV beams to the plasma. Although there are substantial differences in the needs for protection, when handling multi-MW heating systems, and in data throughput for many diagnostics, the formal processes needed to translate system requirements into Instrumentation and Control are identical. Due to the distributed procurement of ITER sub-systems and the need to integrate as painlessly as possible to CODAC, the formal processes, together with a substantial degree of standardization, are even more than usually essential. Starting from the technical, safety and protection, integration and operation requirements, a loop of functional analysis and signal listing is used to generate the controller configuration and the conceptual architecture. These elements in their turn lead to the physical and software design. The paper will describe the formal processes of control system design and the methods used by the ITER project to achieve the standardization of systems engineering practices. These have been applied to several use-cases covering all operation relevant phases such as plasma operation, maintenance, testing and conditioning. There are a number of running contracts that are developing

  2. Massive pulmonary embolism: the predisposing and complicating factors, its current diagnostic approaches and critical importance of early diagnostic physical exam

    Directory of Open Access Journals (Sweden)

    Filip A. Konecny

    2006-12-01

    Full Text Available Massive pulmonary embolism (MPE often leads to circulation collapse, a form of shock. The process is set off by thrombus or multiple thrombi dislodgement followed by a rapid perfusion insufficiency of pulmonary arterial system. Patients experience severe hypotension with diastolic and systolic failure with an acute tricuspid regurgitation. On many occasions, release of an obstruction is unattainable and death is occurring frequently within one hour of presentation. A key reported source of MPE is its occurrence as a complication of deep vein thrombosis (DVT. While long-term immobilization and surgery are both directly associated with MPE, others such as previous DVT, malignancy, infectious lung and heart diseases, family thrombophilia, lower limb paralysis and pregnancy have to be considered as risk factors mainly due to its silent nature. Predisposing and complicating risks should be addressed by an early diagnostic physical exam. The clinician might offer a wide variety of diagnostic approaches, combining techniques into algorithms to better deal with the embolism severity. Multiple patient life-style changes and decisions to adhere to the proposed plan should be built up on patient-physician team effort. KEY WORDS: Massive pulmonary embolism, predisposing factors, current diagnostic approaches.

  3. The current and future state of companion diagnostics

    Science.gov (United States)

    Agarwal, Amit; Ressler, Dan; Snyder, Glenn

    2015-01-01

    Companion diagnostics are an indispensable part of personalized medicine and will likely continue to rapidly increase in number and application to disease areas. The first companion diagnostics were launched in the 1980s and in the face of significant initial skepticism from drug developers as to whether segmenting a drug’s market through a diagnostic was advisable. The commercial success of drugs such as Herceptin® (trastuzumab) and Gleevec® (imatinib), which both require testing with companion diagnostics before they can be prescribed, has moved the entire companion diagnostic field forward. From an initial start of a handful of oncology drugs with corresponding diagnostics, the field has expanded to include multiple therapeutic areas, and the number of combinations has grown by 12-fold. Based on drugs in clinical trials, the rapid growth will likely continue for the foreseeable future. This expansion of companion diagnostics will also have a global component as markets in Europe will evolve in a similar but not identical pattern as the US. One of the greatest challenges to future growth in companion diagnostics is aligning the incentives of all stakeholders. A major driver of growth will continue to be the economic incentives for drug developers to pair their products with diagnostics. However, diagnostic companies are caught between the conflicting demands of two major stakeholders, pharmaceutical companies on one hand and payers/providers on the other. Regulators are also becoming more demanding in aligning development time lines between drugs and diagnostics. In order to survive and prosper, diagnostic companies will need to think more broadly about companion diagnostics than the historical match between a specific drug and a single diagnostic. They will also have to continue the process of consolidation and global expansion that the industry has already begun. Despite these potential obstacles, companion diagnostics have become one of the hottest areas

  4. Resonant laser techniques for combustion and flow diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Fritzon, Rolf

    1998-05-01

    This thesis presents results from two areas of research. Firstly, the resonant coherent laser techniques polarization spectroscopy (PS), degenerate four-wave mixing (DFWM) and stimulated emission (SE) have been developed in the general field of combustion diagnostics. Secondly, laser induced fluorescence (LIF) has been developed and applied for the visualization of mixture fractions in turbulent non reacting flows. PS was developed for instantaneous two-dimensional imaging of minor species in flames, the technique being demonstrated on OH and NO. Various aspects of imaging and of detection in general were investigated. Two-photon induced PS was demonstrated for the detection of NH{sub 3}, CO and N{sub 2} molecules. LIF was monitored simultaneously to allow a quantitative comparison between the techniques. Furthermore, PS and DFWM were developed for instantaneous two-dimensional OH temperature imaging. Through a novel experimental approach based on the use of a dual-wavelength dye laser and a diffraction grating the temperature imaging measurements were performed using only one laser and one CCD camera. A comparison between the two techniques was made. SE was through a crossed-beam arrangement developed for spatially resolved detection of flame species. Two-dimensional LIF was developed and applied for measuring mixture fractions in the shear layer between two co-flowing turbulent gaseous jets. The technique was further applied in a study of the mixing of a turbulent water jet impinging orthogonally onto a flat surface. Average concentration fields in the center-plane of the jet was compared with results from large eddy simulations and with data from the literature 221 refs, 48 figs, 5 tabs

  5. Laser diagnodent: a comparative study with other diagnostic techniques

    International Nuclear Information System (INIS)

    Godinho, Reugma Rego

    2002-01-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  6. Reliability of diagnostic imaging techniques in suspected acute appendicitis: proposed diagnostic protocol

    International Nuclear Information System (INIS)

    Cura del, J. L.; Oleaga, L.; Grande, D.; Vela, A. C.; Ibanez, A. M.

    2001-01-01

    To study the utility of ultrasound and computed tomography (CT) in case of suspected appendicitis. To determine the diagnostic yield in terms of different clinical contexts and patient characteristics. to assess the costs and benefits of introducing these techniques and propose a protocol for their use. Negative appendectomies, complications and length of hospital stay in a group of 152 patients with suspected appendicitis who underwent ultrasound and CT were compared with those of 180 patients who underwent appendectomy during the same time period, but had not been selected for the first group: these patients costs for each group were calculated. In the first group, the diagnostic value of the clinical signs was also evaluated. The reliability of the clinical signs was limited, while the results with ultrasound and CT were excellent. The incidence of negative appendectomy was 9.6% in the study group and 12.2% in the control group. Moreover, there were fewer complications and a shorter hospital stay in the first group. Among men, however, the rate of negative appendectomy was lower in the control group. The cost of using ultrasound and CT in the management of appendicitis was only slightly higher than that of the control group. Although ultrasound and CT are not necessary in cases in which the probability of appendicitis is low or in men presenting clear clinical evidence, the use of these techniques is indicated in the remaining cases in which appendicitis is suspected. In children, ultrasound is the technique of choice. In all other patients, if negative results are obtained with one of the two techniques, the other should be performed. (Author) 49 refs

  7. Diagnostics

    DEFF Research Database (Denmark)

    Donné, A.J.H.; Costley, A.E.; Barnsley, R.

    2007-01-01

    of the measurements—time and spatial resolutions, etc—will in some cases be more stringent. Many of the measurements will be used in the real time control of the plasma driving a requirement for very high reliability in the systems (diagnostics) that provide the measurements. The implementation of diagnostic systems...... on ITER is a substantial challenge. Because of the harsh environment (high levels of neutron and gamma fluxes, neutron heating, particle bombardment) diagnostic system selection and design has to cope with a range of phenomena not previously encountered in diagnostic design. Extensive design and R......&D is needed to prepare the systems. In some cases the environmental difficulties are so severe that new diagnostic techniques are required. The starting point in the development of diagnostics for ITER is to define the measurement requirements and develop their justification. It is necessary to include all...

  8. Current and future developments in nucleic acid-based diagnostics

    International Nuclear Information System (INIS)

    Viljoen, G.J.; Romito, M.; Kara, P.D.

    2005-01-01

    The detection and characterization of specific nucleic acids of medico-veterinary pathogens have proven invaluable for diagnostic purposes. Apart from hybridization and sequencing techniques, polymerase chain reaction (PCR) and numerous other methods have contributed significantly to this process. The integration of amplification and signal detection systems, including on-line real-time devices, have increased speed and sensitivity and greatly facilitated the quantification of target nucleic acids. They have also allowed for sequence characterization using melting or hybridization curves. Rugged portable real-time instruments for field use and robotic devices for processing samples are already available commercially. Various stem-loop DNA probes have been designed to have greater specificity for target recognition during real-time PCR. Various DNA fingerprinting techniques or post amplification sequencing are used to type pathogenic strains. Characterization according to DNA sequence is becoming more readily available as automated sequencers become more widely used. Reverse hybridization and to a greater degree DNA micro-arrays, are being used for genotyping related organisms and can allow for the detection of a large variety of different pathogens simultaneously. Non-radioactive labelling of DNA, especially using fluorophores and the principles of fluorescence resonance energy transfer, is now widely used, especially in real-time detection devices. Other detection methods include the use of surface plasmon resonance and MALDI-TOF mass spectrometry. In addition to these technological advances, contributions by bioinformatics and the description of unique signatures of DNA sequences from pathogens will contribute to the development of further assays for monitoring presence of pathogens. An important goal will be the development of robust devices capable of sensitively and specifically detecting a broad spectrum of pathogens that will be applicable for point

  9. New diagnostic technique for Zeeman-compensated atomic beam slowing: technique and results

    OpenAIRE

    Molenaar, P.A.; Straten, P. van der; Heideman, H.G.M.; Metcalf, H.

    1997-01-01

    We have developed a new diagnostic tool for the study of Zeeman-compensated slowing of an alkali atomic beam. Our time-of-flight technique measures the longitudinal veloc- ity distribution of the slowed atoms with a resolution below the Doppler limit of 30 cm/s. Furthermore, it can map the position and velocity distribution of atoms in either ground hyperfine level inside the solenoid without any devices inside the solenoid. The technique reveals the optical pumping ef- fects, and shows in de...

  10. Electrical-Based Diagnostic Techniques for Assessing Insulation Condition in Aged Transformers

    Directory of Open Access Journals (Sweden)

    Issouf Fofana

    2016-08-01

    Full Text Available The condition of the internal cellulosic paper and oil insulation are of concern for the performance of power transformers. Over the years, a number of methods have been developed to diagnose and monitor the degradation/aging of the transformer internal insulation system. Some of this degradation/aging can be assessed from electrical responses. Currently there are a variety of electrical-based diagnostic techniques available for insulation condition monitoring of power transformers. In most cases, the electrical signals being monitored are due to mechanical or electric changes caused by physical changes in resistivity, inductance or capacitance, moisture, contamination or aging by-products in the insulation. This paper presents a description of commonly used and modern electrical-based diagnostic techniques along with their interpretation schemes.

  11. Selection of suitable diagnostic techniques for an RF atmospheric pressure plasma

    International Nuclear Information System (INIS)

    Kong, M.G.; Deng, X.T.

    2001-01-01

    As an early report of our study, this paper summaries the RF atmospheric pressure plasma system we intend to characterize and a number of diagnostic techniques presently under assessment for our plasma rig. By discussing the advantages and disadvantages of these diagnostic techniques at this meeting, we hope to gain feedback and comments to improve our choice of appropriate diagnostic techniques as well as our subsequent application of these techniques to nonthermal RF atmospheric pressure plasmas

  12. Pancreatic Cancer Diagnostics and Treatment – Current State

    Directory of Open Access Journals (Sweden)

    Zdeněk Krška

    2015-01-01

    Full Text Available Pancreatic ductal adenocarcinoma (PDAC represents permanent and ever rising issue worldwide. Five-year survival does not exceed 3 to 6%, i.e. the worst result among solid tumours. The article evaluates the current state of PDAC diagnostics and treatment specifying also development and trends. Percentage of non-resectable tumours due to locally advanced or metastatic condition varies 60–80%, mostly over 80%. Survival with non-resectable PDAC is 4 to 8 months (median 3.5. In contrast R0 resection shows the survival 18–27 months. Laboratory and imaging screening methods are not indicated on large scale. Risk factors are smoking, alcohol abuse, chronic pancreatitis, diabetes mellitus. Genetic background in most PDAC has not been detected yet. Some genes connected with high risk of PDAC (e.g. BRCA2, PALB2 have been identified as significant and highly penetrative, but link between PDAC and these genes can be seen only in 10–20%. This article surveys perspective oncogenes, tumour suppressor genes, microRNA. Albeit CT is still favoured over other imaging methods, involvement of NMR rises. Surgery prefers the “vessel first” approach, which proves to be justified especially in R0 resection. According to EBM immunotherapy same as radiotherapy are not significant in PDAC treatment. Chemotherapy shows limited importance in conversion treatment of locally advanced or borderline tumours or in case of metastatic spread. Unified procedures cannot be defined due to inhomogenous arrays. Surgical resection is the only chance for curative treatment of PDAC and depends mainly on timely indication for surgery and quality of multidisciplinary team in a high-volume centre.

  13. Development of advanced strain diagnostic techniques for reactor environments.

    Energy Technology Data Exchange (ETDEWEB)

    Fleming, Darryn D.; Holschuh, Thomas Vernon,; Miller, Timothy J.; Hall, Aaron Christopher; Urrea, David Anthony,; Parma, Edward J.,

    2013-02-01

    The following research is operated as a Laboratory Directed Research and Development (LDRD) initiative at Sandia National Laboratories. The long-term goals of the program include sophisticated diagnostics of advanced fuels testing for nuclear reactors for the Department of Energy (DOE) Gen IV program, with the future capability to provide real-time measurement of strain in fuel rod cladding during operation in situ at any research or power reactor in the United States. By quantifying the stress and strain in fuel rods, it is possible to significantly improve fuel rod design, and consequently, to improve the performance and lifetime of the cladding. During the past year of this program, two sets of experiments were performed: small-scale tests to ensure reliability of the gages, and reactor pulse experiments involving the most viable samples in the Annulated Core Research Reactor (ACRR), located onsite at Sandia. Strain measurement techniques that can provide useful data in the extreme environment of a nuclear reactor core are needed to characterize nuclear fuel rods. This report documents the progression of solutions to this issue that were explored for feasibility in FY12 at Sandia National Laboratories, Albuquerque, NM.

  14. Monte Carlo techniques in diagnostic and therapeutic nuclear medicine

    International Nuclear Information System (INIS)

    Zaidi, H.

    2002-01-01

    Monte Carlo techniques have become one of the most popular tools in different areas of medical radiation physics following the development and subsequent implementation of powerful computing systems for clinical use. In particular, they have been extensively applied to simulate processes involving random behaviour and to quantify physical parameters that are difficult or even impossible to calculate analytically or to determine by experimental measurements. The use of the Monte Carlo method to simulate radiation transport turned out to be the most accurate means of predicting absorbed dose distributions and other quantities of interest in the radiation treatment of cancer patients using either external or radionuclide radiotherapy. The same trend has occurred for the estimation of the absorbed dose in diagnostic procedures using radionuclides. There is broad consensus in accepting that the earliest Monte Carlo calculations in medical radiation physics were made in the area of nuclear medicine, where the technique was used for dosimetry modelling and computations. Formalism and data based on Monte Carlo calculations, developed by the Medical Internal Radiation Dose (MIRD) committee of the Society of Nuclear Medicine, were published in a series of supplements to the Journal of Nuclear Medicine, the first one being released in 1968. Some of these pamphlets made extensive use of Monte Carlo calculations to derive specific absorbed fractions for electron and photon sources uniformly distributed in organs of mathematical phantoms. Interest in Monte Carlo-based dose calculations with β-emitters has been revived with the application of radiolabelled monoclonal antibodies to radioimmunotherapy. As a consequence of this generalized use, many questions are being raised primarily about the need and potential of Monte Carlo techniques, but also about how accurate it really is, what would it take to apply it clinically and make it available widely to the medical physics

  15. The current contribution of diagnostic radiology to the population dose in Great Britain

    International Nuclear Information System (INIS)

    Wall, B.F.; Rae, S.; Kendall, G.M.; Darby, S.C.; Fischer, E.S.; Harries, S.V.

    1980-01-01

    The National Radiological Protection Board of the UK has just completed a national survey to determine the genetically significant dose (GSD) to the population of Great Britain from diagnostic radiology. A statistically selected sample of about 80 hospitals spread throughout England, Scotland and Wales has supplied information on the numbers of patients examined in their X-ray departments during a week in June 1977, together with details of age, sex and examination technique. This sample is sufficient to make a reliable estimate of the total diagnostic work-load in all National Health Service Hospitals throughout Great Britain for a year. Gonadal doses from 16 examination types that are likely to be the main contributors to the GSD have been measured on nearly 5000 patients at 20 hospitals throug'out the country using specially developed thermoluminescent dosemeters. These gonadal doses are combined with the examination frequency figures and current values for child expectancy derived from data supplied by tthe registrar general, to estimate the GSD. Those changes in practice which have occurred since the late 1950's which may have influenced the new value for the GSD are discussed, as well as the progress that has been made in estimating population somatic doses from diagnostic radiology using clinical measurements that are currently underway. (H.K.)

  16. Diagnostic imaging techniques in Rubinstein-Taybi syndrome

    International Nuclear Information System (INIS)

    Albanese, A.; Carcione, A.; Benenati, A.; Albano, S.; Rubino, F.P.; Reina, C.; Verde, V.; Giuffre, L.; Corsello, G.; Cammarata, M.; Piccione, M.

    1991-01-01

    Both etiology and pathogenesis of Rubinstein-Taybi syndrome (RTS) are still questionable, even though a genetic factor seems to be certain. A typical face, psychomotor delay, and thumb and halluces abnormalities (big, prevalently short, and often 'spoon-like' toes) are the main characteristic patterns of RTS. Eight subjects (4 male and 3 female children aged 26 days-7 years, and a 31-year old woman, mother of 1 of the affected children) with different signs of RTS were studied over the last 3 years. The results are here reported, with a special emphasis on malformations detected with conventional radiography (Rx), Computerized Tomography (CT), and ultrasound (US). Evaluated parameters were thumbs and halluces (Rx), bone age and skeleton (Rx), cranium (Rx) and encephalon (US, CT), cryptochidism (US, CT), and urogical (Rx, US) and carciovascolar (US) system. Atypical face and psycomotor delay were found in all cases, while thumb and halluces abnormalities were observed only in 6 cases. Among several clinical signs of RTS, we found: severe (<3rd centile) bone maturation delay in 4 cases; skull volume reduction (<50th centile) in 3 subjects and microcrania in 4; skeletal abnormalities in 7 cases (5 of them positive for bilateral coxofemoral abnormalities); urinary tract (4 cases) and cardiovascular (3 cases) malformation; and cryptorcidism in 3 of 4 males. A case was diagnosed during neonatal period (within the first month of life) it was a rare case associated with a variant form of Dandy-Walker anomaly; semiologic similarities were observed between mother and daughter patients. X-rays, US and CT rarely play an important role in the diagnosis of RTS, considering the several clinical signs, mainly tha face, affecting the patients. However, diagnostic imaging techniques help diagnose hidden malformations and confirm and integrate clinical signs

  17. Consideration on the diagnostic ability of various imaging techniques in relation to renal tumor

    International Nuclear Information System (INIS)

    Ike, Katsushi

    1984-01-01

    Radiological diagnosis of renal tumors is being improved with the increased imaging accuracy which has resulted from advancement in the various equipment used and improvement in techniques. However, at the clinical level, diagnostic procedures based on the characteristics of the delineated images are not yet established and the diverse diagnostic procedures are being conducted currently in a stereotyped manner. In this study, the images of 61 cases diagnosed as renal tumor were analysed retrospectively with the purpose of establishing the imaging accuracy, capacity for diagnosis based on image characteristics and a subseguent proper diagnostic procedure. It was found that CT and Angio gave similar diagnostic accuracy. It was further revealed that US images enabled to differentiate renal tumors from the more commonly experienced renal cystic disease. For determination of tunica involucrum infiltration, which is essential to diagnose Stage I and II renal tumors, CT was proved to be superior to Angio. CT and US were also to be so in the determination of metastasis to para-aortic lymph nodes which is a Stage III criterion. In recent years, CT and US imaging accuracies have increased, hence the improvement in the capacity to diagnose non-observable renal tumors is highly expected. (author)

  18. Valve Calcification in Aortic Stenosis: Etiology and Diagnostic Imaging Techniques

    Directory of Open Access Journals (Sweden)

    María Manuela Izquierdo-Gómez

    2017-01-01

    Full Text Available Aortic stenosis is the most common valvulopathy in the Western world. Its prevalence has increased significantly in recent years due to population aging; hence, up to 8% of westerners above the age of 84 now have severe aortic stenosis (Lindroos et al., 1993. This causes increased morbidity and mortality and therein lies the importance of adequate diagnosis and stratification of the degree of severity which allows planning the best therapeutic option in each case. Long understood as a passive age-related degenerative process, it is now considered a rather more complex entity involving mechanisms and factors similar to those of atherosclerosis (Stewart et al., 1997. In this review, we summarize the pathophysiological mechanisms underlying the onset and progression of the disease and analyze the current role of cardiac imaging techniques for diagnosis.

  19. TOF technique for laser-driven proton beam diagnostics for the ELIMED beamline

    International Nuclear Information System (INIS)

    Milluzzo, G.; Scuderi, V.; Amico, A.G.; Cirrone, G.A.P.; Cuttone, G.; Larosa, G.; Leanza, R.; Petringa, G.; Pipek, J.; Romano, F.; Napoli, M. De; Dostal, J.; Margarone, D.; Schillaci, F.; Velyhan, A.

    2017-01-01

    The Time of Flight (TOF) method for laser-driven ion beam diagnostics has been extensively investigated so far for low energy ion diagnostics and several works, reported in literature [1,2], have shown its efficiency in the measurement of particle beam characteristics such as ion species, energy spectrum and current. Moreover, such technique allows obtaining a shot-to-shot on-line monitoring of optically accelerated particles, necessary to control the reproducibility of the accelerated beam and to deliver a beam suitable for any kind of applications. For this reason, the ELIMED beamline [3,4], which will be entirely developed at INFN-LNS and installed in 2017 within the ion beamline ELIMAIA (ELI Multidisciplinary Applications of laser-Ion Acceleration) experimental hall at ELI-Beamlines in Prague, will be equipped with an on-line diagnostics system composed by silicon carbide and diamond detectors, using the TOF technique. In this contribution, the procedure developed for TOF signal analysis will be briefly reported.

  20. Dysphagia in Children with Esophageal Atresia: Current Diagnostic Options

    OpenAIRE

    Rayyan, Maissa; Allegaert, Karel; Omari, Taher; Rommel, Nathalie

    2015-01-01

    Dysphagia or swallowing disorder is very common (range, 15-52%) in patients with esophageal atresia. Children present with a wide range of symptoms. The most common diagnostic tools to evaluate esophageal dysphagia, such as upper barium study and manometry, aim to characterize anatomy and function of the esophageal body and the esophagogastric junction (EGJ). Using these technologies, a variety of pathological motor patterns have been identified in children with esophageal atresia. However, t...

  1. Current and future molecular diagnostics for ocular infectious diseases.

    Science.gov (United States)

    Doan, Thuy; Pinsky, Benjamin A

    2016-11-01

    Confirmation of ocular infections can pose great challenges to the clinician. A fundamental limitation is the small amounts of specimen that can be obtained from the eye. Molecular diagnostics can circumvent this limitation and have been shown to be more sensitive than conventional culture. The purpose of this review is to describe new molecular methods and to discuss the applications of next-generation sequencing-based approaches in the diagnosis of ocular infections. Efforts have focused on improving the sensitivity of pathogen detection using molecular methods. This review describes a new molecular target for Toxoplasma gondii-directed polymerase chain reaction assays. Molecular diagnostics for Chlamydia trachomatis and Acanthamoeba species are also discussed. Finally, we describe a hypothesis-free approach, metagenomic deep sequencing, which can detect DNA and RNA pathogens from a single specimen in one test. In some cases, this method can provide the geographic location and timing of the infection. Pathogen-directed PCRs have been powerful tools in the diagnosis of ocular infections for over 20 years. The use of next-generation sequencing-based approaches, when available, will further improve sensitivity of detection with the potential to improve patient care.

  2. Multimodal imaging of vascular network and blood microcirculation by optical diagnostic techniques

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Meglinski, I V

    2011-01-01

    We present a multimodal optical diagnostic approach for simultaneous non-invasive in vivo imaging of blood and lymphatic microvessels, utilising a combined use of fluorescence intravital microscopy and a method of dynamic light scattering. This approach makes it possible to renounce the use of fluorescent markers for visualisation of blood vessels and, therefore, significantly (tenfold) reduce the toxicity of the technique and minimise side effects caused by the use of contrast fluorescent markers. We demonstrate that along with the ability to obtain images of lymph and blood microvessels with a high spatial resolution, current multimodal approach allows one to observe in real time permeability of blood vessels. This technique appears to be promising in physiology studies of blood vessels, and especially in the study of peripheral cardiovascular system in vivo. (optical technologies in biophysics and medicine)

  3. Update in Current Diagnostics and Therapeutics of Dry Eye Disease.

    Science.gov (United States)

    Thulasi, Praneetha; Djalilian, Ali Reza

    2017-11-01

    Dry eye disease (DED) represents a heterogeneous group of conditions with tear film insufficiency and signs and/or symptoms of ocular surface irritation. The clinical manifestations of DED can be highly variable; hence the diagnosis is often based on a combination of symptoms, signs, and clinical tests, given that any one of these alone would miss a significant number of patients. Similarly, the treatment must often be tailored to each patient by targeting the specific mechanisms involved in his or her disease. The purpose of this review is to summarize recent advances that have allowed us to better recognize, categorize, and treat patients with DED. The most notable new diagnostic tests in DED are tear film osmolarity, inflammatory biomarkers, and meibomian gland imaging. Therapeutically, anti-inflammatory therapy, meibomian gland heating and expression, and scleral contact lenses are some of the latest options available for treating DED. Copyright © 2017 American Academy of Ophthalmology. Published by Elsevier Inc. All rights reserved.

  4. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    International Nuclear Information System (INIS)

    Upadhyaya, B.R.; Yan, W.; Henry, G.

    1999-01-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  5. Development of a diagnostic expert system for eddy current data analysis using applied artificial intelligence methods

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, B.R.; Yan, W. [Tennessee Univ., Knoxville, TN (United States). Dept. of Nuclear Engineering; Behravesh, M.M. [Electric Power Research Institute, Palo Alto, CA (United States); Henry, G. [EPRI NDE Center, Charlotte, NC (United States)

    1999-09-01

    A diagnostic expert system that integrates database management methods, artificial neural networks, and decision-making using fuzzy logic has been developed for the automation of steam generator eddy current test (ECT) data analysis. The new system, known as EDDYAI, considers the following key issues: (1) digital eddy current test data calibration, compression, and representation; (2) development of robust neural networks with low probability of misclassification for flaw depth estimation; (3) flaw detection using fuzzy logic; (4) development of an expert system for database management, compilation of a trained neural network library, and a decision module; and (5) evaluation of the integrated approach using eddy current data. The implementation to field test data includes the selection of proper feature vectors for ECT data analysis, development of a methodology for large eddy current database management, artificial neural networks for flaw depth estimation, and a fuzzy logic decision algorithm for flaw detection. A large eddy current inspection database from the Electric Power Research Institute NDE Center is being utilized in this research towards the development of an expert system for steam generator tube diagnosis. The integration of ECT data pre-processing as part of the data management, fuzzy logic flaw detection technique, and tube defect parameter estimation using artificial neural networks are the fundamental contributions of this research. (orig.)

  6. Autoimmune liver serology: current diagnostic and clinical challenges.

    Science.gov (United States)

    Bogdanos, Dimitrios-P; Invernizzi, Pietro; Mackay, Ian-R; Vergani, Diego

    2008-06-07

    Liver-related autoantibodies are crucial for the correct diagnosis and classification of autoimmune liver diseases (AiLD), namely autoimmune hepatitis types 1 and 2 (AIH-1 and 2), primary biliary cirrhosis (PBC), and the sclerosing cholangitis variants in adults and children. AIH-1 is specified by anti-nuclear antibody (ANA) and smooth muscle antibody (SMA). AIH-2 is specified by antibody to liver kidney microsomal antigen type-1 (anti-LKM1) and anti-liver cytosol type 1 (anti-LC1). SMA, ANA and anti-LKM antibodies can be present in de-novo AIH following liver transplantation. PBC is specified by antimitochondrial antibodies (AMA) reacting with enzymes of the 2-oxo-acid dehydrogenase complexes (chiefly pyruvate dehydrogenase complex E2 subunit) and disease-specific ANA mainly reacting with nuclear pore gp210 and nuclear body sp100. Sclerosing cholangitis presents as at least two variants, first the classical primary sclerosing cholangitis (PSC) mostly affecting adult men wherein the only (and non-specific) reactivity is an atypical perinuclear antineutrophil cytoplasmic antibody (p-ANCA), also termed perinuclear anti-neutrophil nuclear antibodies (p-ANNA) and second the childhood disease called autoimmune sclerosing cholangitis (ASC) with serological features resembling those of type 1 AIH. Liver diagnostic serology is a fast-expanding area of investigation as new purified and recombinant autoantigens, and automated technologies such as ELISAs and bead assays, become available to complement (or even compete with) traditional immunofluorescence procedures. We survey for the first time global trends in quality assurance impacting as it does on (1) manufacturers/purveyors of kits and reagents, (2) diagnostic service laboratories that fulfill clinicians' requirements, and (3) the end-user, the physician providing patient care, who must properly interpret test results in the overall clinical context.

  7. Electromagnetic considerations for RF current density imaging [MRI technique].

    Science.gov (United States)

    Scott, G C; Joy, M G; Armstrong, R L; Henkelman, R M

    1995-01-01

    Radio frequency current density imaging (RF-CDI) is a recent MRI technique that can image a Larmor frequency current density component parallel to B(0). Because the feasibility of the technique was demonstrated only for homogeneous media, the authors' goal here is to clarify the electromagnetic assumptions and field theory to allow imaging RF currents in heterogeneous media. The complete RF field and current density imaging problem is posed. General solutions are given for measuring lab frame magnetic fields from the rotating frame magnetic field measurements. For the general case of elliptically polarized fields, in which current and magnetic field components are not in phase, one can obtain a modified single rotation approximation. Sufficient information exists to image the amplitude and phase of the RF current density parallel to B(0) if the partial derivative in the B(0) direction of the RF magnetic field (amplitude and phase) parallel to B(0) is much smaller than the corresponding current density component. The heterogeneous extension was verified by imaging conduction and displacement currents in a phantom containing saline and pure water compartments. Finally, the issues required to image eddy currents are presented. Eddy currents within a sample will distort both the transmitter coil reference system, and create measurable rotating frame magnetic fields. However, a three-dimensional electro-magnetic analysis will be required to determine how the reference system distortion affects computed eddy current images.

  8. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    International Nuclear Information System (INIS)

    Didier, Ryne A.; Vajtai, Petra L.; Hopkins, Katharine L.

    2015-01-01

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI vol ). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI vol . Reduced CTDI vol was achieved primarily by reductions in effective tube current-time product (mAs eff ) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI vol , size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI vol was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI vol and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  9. Iterative reconstruction technique with reduced volume CT dose index: diagnostic accuracy in pediatric acute appendicitis

    Energy Technology Data Exchange (ETDEWEB)

    Didier, Ryne A. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Vajtai, Petra L. [Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States); Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Hopkins, Katharine L. [Oregon Health and Science University, Department of Diagnostic Radiology, DC7R, Portland, OR (United States); Oregon Health and Science University, Department of Pediatrics, Portland, OR (United States)

    2014-07-05

    Iterative reconstruction technique has been proposed as a means of reducing patient radiation dose in pediatric CT. Yet, the effect of such reductions on diagnostic accuracy has not been thoroughly evaluated. This study compares accuracy of diagnosing pediatric acute appendicitis using contrast-enhanced abdominopelvic CT scans performed with traditional pediatric weight-based protocols and filtered back projection reconstruction vs. a filtered back projection/iterative reconstruction technique blend with reduced volume CT dose index (CTDI{sub vol}). Results of pediatric contrast-enhanced abdominopelvic CT scans done for pain and/or suspected appendicitis were reviewed in two groups: A, 192 scans performed with the hospital's established weight-based CT protocols and filtered back projection reconstruction; B, 194 scans performed with iterative reconstruction technique and reduced CTDI{sub vol}. Reduced CTDI{sub vol} was achieved primarily by reductions in effective tube current-time product (mAs{sub eff}) and tube peak kilovoltage (kVp). CT interpretation was correlated with clinical follow-up and/or surgical pathology. CTDI{sub vol}, size-specific dose estimates (SSDE) and performance characteristics of the two CT techniques were then compared. Between groups A and B, mean CTDI{sub vol} was reduced by 45%, and mean SSDE was reduced by 46%. Sensitivity, specificity and diagnostic accuracy were 96%, 97% and 96% in group A vs. 100%, 99% and 99% in group B. Accuracy in diagnosing pediatric acute appendicitis was maintained in contrast-enhanced abdominopelvic CT scans that incorporated iterative reconstruction technique, despite reductions in mean CTDI{sub vol} and SSDE by nearly half as compared to the hospital's traditional weight-based protocols. (orig.)

  10. Indications and new diagnostic techniques in micturating cystourethrographic studies

    International Nuclear Information System (INIS)

    Schuster, W.; Bruenger, J.

    1978-01-01

    Urological radiographic procedures on children are of great importance. The frequency of examinations is comparable to the number of Gl tract studies. In diagnosing chronically recurrent urinary tract infections, micturating cystourethrography is a valuable addition to excretory urography. Indications and performance of micturating cystourethrography at juvenile age are described. All measures reducing radiation exposure must be taken into consideration. New technological devices grant improved diagnostic information with a minimal radiation exposure for patients. (orig.) [de

  11. Tunable diode laser spectroscopy as a technique for combustion diagnostics

    International Nuclear Information System (INIS)

    Bolshov, M.A.; Kuritsyn, Yu.A.; Romanovskii, Yu.V.

    2015-01-01

    Tunable diode laser absorption spectroscopy (TDLAS) has become a proven method of rapid gas diagnostics. In the present review an overview of the state of the art of TDL-based sensors and their applications for measurements of temperature, pressure, and species concentrations of gas components in harsh environments is given. In particular, the contemporary tunable diode laser systems, various methods of absorption detection (direct absorption measurements, wavelength modulation based phase sensitive detection), and relevant algorithms for data processing that improve accuracy and accelerate the diagnostics cycle are discussed in detail. The paper demonstrates how the recent developments of these methods and algorithms made it possible to extend the functionality of TDLAS in the tomographic imaging of combustion processes. Some prominent examples of applications of TDL-based sensors in a wide range of practical combustion aggregates, including scramjet engines and facilities, internal combustion engines, pulse detonation combustors, and coal gasifiers, are given in the final part of the review. - Highlights: • Overview of modern TDL-based sensors for combustion • TDL systems, methods of absorption detection and algorithms of data processing • Prominent examples of TDLAS diagnostics of the combustion facilities • Extension of the TDLAS on the tomographic imaging of combustion processes

  12. Reference materials for molecular diagnostics: Current achievements and future strategies.

    Science.gov (United States)

    Jing, Rongrong; Wang, Huimin; Ju, Shaoqing; Cui, Ming

    2018-06-01

    Molecular diagnoses have become more widespread in many areas of laboratory medicine where qualitative or quantitative approaches are used to detect nucleic acids. The increasing number of assay methods and the targets for molecular diagnostics contribute to variability in the test results among clinical laboratories. Thus, reference materials (RMs) are required to enhance the comparability of results. This review focuses on the definition of RMs as well as the production and characteristics of higher order RMs from different organizations and their future strategies. We describe the recent progress in RMs, including the definition of RMs by the Joint Committee for Guides in Metrology, as well as the production and characteristics of higher order RMs by international official bodies. There is an urgent need for RMs in nucleic acid testing, especially higher order RMs. To advance the harmonization and standardization of clinical nucleic acid detection, cooperation between the above organizations is proposed and different approaches to higher order RMs development are also needed. Copyright © 2018 The Canadian Society of Clinical Chemists. Published by Elsevier Inc. All rights reserved.

  13. Dysphagia in Children with Esophageal Atresia: Current Diagnostic Options.

    Science.gov (United States)

    Rayyan, Maissa; Allegaert, Karel; Omari, Taher; Rommel, Nathalie

    2015-08-01

    Dysphagia or swallowing disorder is very common (range, 15-52%) in patients with esophageal atresia. Children present with a wide range of symptoms. The most common diagnostic tools to evaluate esophageal dysphagia, such as upper barium study and manometry, aim to characterize anatomy and function of the esophageal body and the esophagogastric junction (EGJ). Using these technologies, a variety of pathological motor patterns have been identified in children with esophageal atresia. However, the most challenging part of diagnosing patients with esophageal dysphagia lies in the fact that these methods fail to link functional symptoms such as dysphagia with the esophageal motor disorders observed. A recent method, called pressure-flow analysis (PFA), uses simultaneously acquired impedance and manometry measurements, and applies an integrated analysis of these recordings to derive quantitative pressure-flow metrics. These pressure-flow metrics allow detection of the interplay between bolus flow, motor patterns, and symptomatology by combining data on bolus transit and bolus flow resistance. Based on a dichotomous categorization, flow resistance at the EGJ and ineffective esophageal bolus transit can be determined. This method has the potential to guide therapeutic decisions for esophageal dysmotility in pediatric patients with esophageal atresia. Georg Thieme Verlag KG Stuttgart · New York.

  14. A review on diagnostic techniques for brucellosis | Kaltungo | African ...

    African Journals Online (AJOL)

    ... but has not been validated for standard laboratory use. This paper highlights useful samples and, especially the different conventional to more sophisticated molecular techniques for the diagnosis of brucellosis. Keywords: Brucellosis, diagnosis, techniques. African Journal of Biotechnology, Vol. 13(1), pp. 1-10, 1 January, ...

  15. Non-Destructive Techniques Based on Eddy Current Testing

    Science.gov (United States)

    García-Martín, Javier; Gómez-Gil, Jaime; Vázquez-Sánchez, Ernesto

    2011-01-01

    Non-destructive techniques are used widely in the metal industry in order to control the quality of materials. Eddy current testing is one of the most extensively used non-destructive techniques for inspecting electrically conductive materials at very high speeds that does not require any contact between the test piece and the sensor. This paper includes an overview of the fundamentals and main variables of eddy current testing. It also describes the state-of-the-art sensors and modern techniques such as multi-frequency and pulsed systems. Recent advances in complex models towards solving crack-sensor interaction, developments in instrumentation due to advances in electronic devices, and the evolution of data processing suggest that eddy current testing systems will be increasingly used in the future. PMID:22163754

  16. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis.

    Science.gov (United States)

    Canaval Zuleta, Héctor Julián; Company Campins, María M; Dolz Abadía, Carlos

    2016-06-01

    Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  17. Endoscopy as a diagnostic and therapeutic alternative technique of taeniasis

    Directory of Open Access Journals (Sweden)

    Héctor Julian Canaval-Zuleta

    Full Text Available Despite a low incidence in developed countries, gastrointestinal taeniasis should be suspected in patients with abdominal pain, diarrhea, anemia, and/or malabsorption of unknown origin, even more so if they come from endemic regions or areas with poor hygienic and alimentary habits. Diagnosis is traditionally reached by identifying the parasite in stools, but more recently both serological and immunological approaches are also available. Based on a patient diagnosed by gastroscopy, a literature review was undertaken of patients diagnosed by endoscopy. We discuss endoscopy as diagnostic modality, and the effectiveness and safety that endoscopic treatment may provide in view of the potential risk for neurocysticercosis.

  18. Current cardiac imaging techniques for detection of left ventricular mass

    Directory of Open Access Journals (Sweden)

    Celebi Aksuyek S

    2010-06-01

    Full Text Available Abstract Estimation of left ventricular (LV mass has both prognostic and therapeutic value independent of traditional risk factors. Unfortunately, LV mass evaluation has been underestimated in clinical practice. Assessment of LV mass can be performed by a number of imaging modalities. Despite inherent limitations, conventional echocardiography has fundamentally been established as most widely used diagnostic tool. 3-dimensional echocardiography (3DE is now feasible, fast and accurate for LV mass evaluation. 3DE is also superior to conventional echocardiography in terms of LV mass assessment, especially in patients with abnormal LV geometry. Cardiovascular magnetic resonance (CMR and cardiovascular computed tomography (CCT are currently performed for LV mass assessment and also do not depend on cardiac geometry and display 3-dimensional data, as well. Therefore, CMR is being increasingly employed and is at the present standard of reference in the clinical setting. Although each method demonstrates advantages over another, there are also disadvantages to receive attention. Diagnostic accuracy of methods will also be increased with the introduction of more advanced systems. It is also likely that in the coming years new and more accurate diagnostic tests will become available. In particular, CMR and CCT have been intersecting hot topic between cardiology and radiology clinics. Thus, good communication and collaboration between two specialties is required for selection of an appropriate test.

  19. Very Fast Current Diagnostic for Linear Pulsed Beams

    Science.gov (United States)

    Nassisi, Vincenzo; Delle Side, Domenico; Turco, Vito

    2018-01-01

    Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn't influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time ( 100 ps), The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  20. Very Fast Current Diagnostic for Linear Pulsed Beams

    Directory of Open Access Journals (Sweden)

    Nassisi Vincenzo

    2018-01-01

    Full Text Available Fast current pulses manage lasers and particle accelerators and require sophisticate systems to be detected. At today Rogowski coils are well known. They are designed and built with a toroidal structure. In recently application, flat transmission lines are imploded and for this reason we develop a linear Rogowski coil to detect current pulses inside flat conductors. To get deep information from the system, it was approached by means of the theory of the transmission lines. The coil we build presents a resistance but it doesn’t influence the rise time of the response, instead the integrating time. We also studied the influence of the magnetic properties of coil support. The new device was able to record pulses of more hundred nanoseconds depending on the inductance, load impedance and resistance of the coil. Furthermore, its response was characterized by a sub-nanosecond rise time (~100 ps, The attenuation coefficient depends mainly on the turn number of the coil, while the quality of the response depends both on the manufacture quality of the coil and on the magnetic core characteristics. In biophysical applications often, a double line is employed in order to have a sample as control and a sample stressed by a light source. So, in this case we build two equal plane lines by 100 Ω characteristic resistance connected in parallel. We diagnosed the current present in a line. The attenuation factor resulted to be 11,5 A/V.

  1. Action Research to Improve the Learning Space for Diagnostic Techniques

    Directory of Open Access Journals (Sweden)

    Ellen Ariel

    2015-08-01

    Full Text Available The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of “knowledge” and “understanding.” The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001, it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed.

  2. Action Research to Improve the Learning Space for Diagnostic Techniques.

    Science.gov (United States)

    Ariel, Ellen; Owens, Leigh

    2015-12-01

    The module described and evaluated here was created in response to perceived learning difficulties in diagnostic test design and interpretation for students in third-year Clinical Microbiology. Previously, the activities in lectures and laboratory classes in the module fell into the lower cognitive operations of "knowledge" and "understanding." The new approach was to exchange part of the traditional activities with elements of interactive learning, where students had the opportunity to engage in deep learning using a variety of learning styles. The effectiveness of the new curriculum was assessed by means of on-course student assessment throughout the module, a final exam, an anonymous questionnaire on student evaluation of the different activities and a focus group of volunteers. Although the new curriculum enabled a major part of the student cohort to achieve higher pass grades (p < 0.001), it did not meet the requirements of the weaker students, and the proportion of the students failing the module remained at 34%. The action research applied here provided a number of valuable suggestions from students on how to improve future curricula from their perspective. Most importantly, an interactive online program that facilitated flexibility in the learning space for the different reagents and their interaction in diagnostic tests was proposed. The methods applied to improve and assess a curriculum refresh by involving students as partners in the process, as well as the outcomes, are discussed. Journal of Microbiology & Biology Education.

  3. Mining for diagnostic information in body surface potential maps: A comparison of feature selection techniques

    Directory of Open Access Journals (Sweden)

    McCullagh Paul J

    2005-09-01

    Full Text Available Abstract Background In body surface potential mapping, increased spatial sampling is used to allow more accurate detection of a cardiac abnormality. Although diagnostically superior to more conventional electrocardiographic techniques, the perceived complexity of the Body Surface Potential Map (BSPM acquisition process has prohibited its acceptance in clinical practice. For this reason there is an interest in striking a compromise between the minimum number of electrocardiographic recording sites required to sample the maximum electrocardiographic information. Methods In the current study, several techniques widely used in the domains of data mining and knowledge discovery have been employed to mine for diagnostic information in 192 lead BSPMs. In particular, the Single Variable Classifier (SVC based filter and Sequential Forward Selection (SFS based wrapper approaches to feature selection have been implemented and evaluated. Using a set of recordings from 116 subjects, the diagnostic ability of subsets of 3, 6, 9, 12, 24 and 32 electrocardiographic recording sites have been evaluated based on their ability to correctly asses the presence or absence of Myocardial Infarction (MI. Results It was observed that the wrapper approach, using sequential forward selection and a 5 nearest neighbour classifier, was capable of choosing a set of 24 recording sites that could correctly classify 82.8% of BSPMs. Although the filter method performed slightly less favourably, the performance was comparable with a classification accuracy of 79.3%. In addition, experiments were conducted to show how (a features chosen using the wrapper approach were specific to the classifier used in the selection model, and (b lead subsets chosen were not necessarily unique. Conclusion It was concluded that both the filter and wrapper approaches adopted were suitable for guiding the choice of recording sites useful for determining the presence of MI. It should be noted however

  4. Current topics in the diagnostic evaluation of the mastocarcinoma

    International Nuclear Information System (INIS)

    Jonat, W.

    1989-01-01

    The mastocarcinoma is the most frequently occurring tumor in women. Unfortunately, all efforts and achievements of the last decades could not significantly enhance the healing rates. Current activities in this field concentrate on novel therapeutical approaches and on improved specification of tumor tissues. Immunology, immunohistochemistry, and pulsed cytophotometry are the methods of interest presently applied for better detection of the proliferative compartment in the tumor material. New monoclonal antibodies have been developed for immunohistochemical receptor analysis, and new tumor markers are applied for enhanced and early detection of recidivations. (orig.) [de

  5. Undifferentiated nasopharyngeal cancer (UCNT): current diagnostic and therapeutic aspects

    International Nuclear Information System (INIS)

    Altun, M.; Fandi, A.; Dupuis, O.; Cvitkovic, E.; Krajina, Z.; Eschwege, F.

    1995-01-01

    Undifferentiated carcinoma of the nasopharynx (UCNT) is a particular head and neck epidermoid lineage tumor related to the Epstein Barr Virus (EBV). It has geographically selective endemic epidemiologic features, without relation to external carcinogens. Its systemic aggressiveness is the source of most disease-related demises, because radiotherapy achieves excellent local control and a significant percentage of cure in patients with exclusive locoregional disease. Differences in the staging systems currently in use, the recent changes in imaging and radiotherapy technology, and the lack of distinction between UCNT and squamous cell carcinoma (SCC) of the nasopharynx in Western literature reports make for some difficulty in therapeutic results evaluation when analyzing available literature. Its chemosensitivity is a relatively recent acknowledged fact, and its use in metastatic patients results in a high percentage of objective responses, many of long duration. Neoadjuvant cisplatin-based chemotherapy seems to be of benefit, but outstanding controversies in this regard will be soon answered through ongoing phase III trials. After a review of the current literature of all the above-mentioned aspects of this fascinating nosologic entity, our own experience, both in metastatic and locoregional disease patients is analyzed

  6. Dose classification scheme for digital imaging techniques in diagnostic radiology

    International Nuclear Information System (INIS)

    Hojreh, A.

    2002-04-01

    Purpose: image quality in diagnostic radiology is determined in crucial extent by the signal-noise-ratio, which is proportional to the applied x-ray dose. Onward technological developments in the diagnostic radiology are therefore frequently connected with a dose increase, which subjectively is hardly or even not perceptible. The aim of this work was to define reproducible standards for image quality as a function of dose and expected therapeutical consequence in case of computed tomography of the paranasal sinuses and the upper and lower jaw (dental CT), whereby practical-clinical purposes are considered. Materials and methods: the image quality of computed tomography of the paranasal sinuses and dental CT was determined by standard deviation of the CT-numbers (pixel noise) in a region of interest of the phantom of American Association of Physicists in Medicine (AAPM phantom) and additionally in the patients CT images. The diagnostic quality of the examination was classified on the basis of patients CT images in three dose levels (low dose, standard dose and high dose). Results: the pixel noise of CT of the paranasal sinuses with soft tissue reconstruction amounts to 19.3 Hounsfield units (HU) for low dose, 8.8 HU for standard dose, and below 8 HU for high dose. The pixel noise of the dental CT with bone (high resolution) reconstruction amounts to 344 HU for low dose, 221 HU for standard dose, and below 200 HU for high dose. Suitable indications for low dose CT are the scanning of body regions with high contrast differences, like the bony delimitations of air-filled spaces of the facial bones, and radiological follow-up examinations with dedicated questions such as axis determination in dental implantology, as well as the images of objects with small diameter such as in case of children. The standard dose CT can be recommended for all cases, in which precise staging of the illness plays an indispensable role for the diagnosis and therapy planning. With high dose

  7. Novel non-intercepting diagnostic techniques for low-emittance relativistic electron beams

    International Nuclear Information System (INIS)

    Moran, M.J.; Chang, B.

    1988-01-01

    Relativistic electron beams are being generated with emittances low enough that diffraction radiation can be used for beam diagnostics. Techniques based on diffraction radiation can be used to measure the beam transverse momentum distribution and to measure the transverse spatial distribution. The radiation is intense and can be in the visible spectral region where optical diagnostic techniques can be used to maximum advantage. 4 refs. 3 figs

  8. Two cases of colossal heamtometra in old women with a difficult preoperative diagnostic technique

    International Nuclear Information System (INIS)

    Aono, Kaname; Fukumoto, Satoru

    1980-01-01

    With the progress in diagnostic imaging techniques, the preoperative diagnostic technique for lesion in the pelvic cavity has become comparatively easy and its clinical usefulness is in high estimation. However, in case of an atypical lesion, it is not always easy to recognize the original organ by traditional imaging pattern. In the present report two cases of colossal hematometra in old women which presented a cystic lesion pattern are dealt with and discussed from a point of medical imagings for diagnosis. (author)

  9. Radiotherapy in prostate cancer. Innovative techniques and current controversies

    International Nuclear Information System (INIS)

    Geinitz, Hans

    2015-01-01

    Examines in detail the role of innovative radiation techniques in the management of prostate cancer, including IMRT, IGRT, BART, and modern brachytherapy. Explores a range of current controversies in patient treatment. Intended for both radiation oncologists and urologists. Radiation treatment is rapidly evolving owing to the coordinated research of physicists, engineers, computer and imaging specialists, and physicians. Today, the arsenal of ''high-precision'' or ''targeted'' radiotherapy includes multimodal imaging, in vivo dosimetry, Monte Carlo techniques for dose planning, patient immobilization techniques, intensity-modulated radiotherapy (IMRT), image-guided radiotherapy (IGRT), biologically adapted radiotherapy (BART), quality assurance methods, novel methods of brachytherapy, and, at the far end of the scale, particle beam radiotherapy using protons and carbon ions. These approaches are like pieces of a puzzle that need to be put together to provide the prostate cancer patient with high-level optimized radiation treatment. This book examines in detail the role of the above-mentioned innovative radiation techniques in the management of prostate cancer. In addition, a variety of current controversies regarding treatment are carefully explored, including whether prophylactic treatment of the pelvic lymphatics is essential, the magnitude of the effect of dose escalation, whether a benefit accrues from hypofractionation, and what evidence exists for the superiority of protons or heavy ions. Radiotherapy in Prostate Cancer: Innovative Techniques and Current Controversies is intended for both radiation oncologists and urologists with an interest in the up-to-date capabilities of modern radiation oncology for the treatment of prostate cancer.

  10. Eddy current technique applied to automated tube profilometry

    International Nuclear Information System (INIS)

    Dobbeni, D.; Melsen, C. van

    1982-01-01

    The use of eddy current methods in the first totally automated pre-service inspection of the internal diameter of PWR steam generator tubes is described. The technique was developed at Laborelec, the Belgian Laboratory of the Electricity Supply Industry. Details are given of the data acquisition system and of the automated manipulator. Representative tube profiles are illustrated. (U.K.)

  11. Current research projects on traffic conflicts technique studies.

    NARCIS (Netherlands)

    Hondel, M. van den & and Kraay, J.H.

    1979-01-01

    A review of current research concerning the development, evaluation and use of the traffic conflicts technique is presented. The 32 studies, selected from the IRRD data base, are listed alphabetically by names of countries and under countries by names of research organizations. The IRRD descriptions

  12. Diagnostic methods and techniques in cervical cancer prevention Part II: Molecular diagnostics of HPV infection

    Directory of Open Access Journals (Sweden)

    Adriana Vince,

    2010-02-01

    Full Text Available Clinical diagnostics of HPV infection is based on analytically andclinically validated assays for qualitative detection of HPV DNAfrom high risk genotypes. New generation of HPV DNA assayscombines qualitative detection of 12 high-risk HPV genotypeswith HPV-16 and HPV-18 genotyping. New generation of HPVmolecular assays designed to increase clinical specificity of moleculartesting is based on detection of mRNA for E6 and E7.

  13. CURRENT ASPECTS OF ACUTE STREPTOCOCCAL TONSILLOPHARYNGITIS DIAGNOSTICS IN CHILDREN

    Directory of Open Access Journals (Sweden)

    D. P. Polyakov

    2013-01-01

    Full Text Available Acute tonsillopharyngitis in children is one of the most common reasons for medical consultations. The majority of acute pharyngeal inflammatory diseases are viral. The frequency of bacterial tonsillopharyngitis in children (the main causative agent is group A Streptococcus, GAS is about 20–30%. In spite of it antibiotics are prescribed for 95% of patients, thus it is inappropriate. On the other hand misdiagnosis of acute streptococcal tonsillopharyngitis and antibiotics refusal can lead to suppurative and nonsuppurative rheumatic complications. Some prominent trials have shown a poor ability of signs and inflammatory biomarkers to identify tonsillopharyngitis streptococcal vs. viral. So it is impossible to use them as indication for antibiotic. The experience of clinical score use (McIsaac etc. have also demonstrated a poor prognostic value. As a result the throat swab culture is the «gold standard» of acute streptococcal tonsillopharyngitis. It has such limitations as rare microbiology labs, method technology, the price and the delay in obtaining result. An alternative technique is GAS rapid antigen detecting test (RADT for the identification of GAS directly from throat swabs. The world data shows a high sensitivity and specificity of modern RADTs.

  14. Computer Tomography: A Novel Diagnostic Technique used in Horses

    African Journals Online (AJOL)

    In Veterinary Medicine, Computer Tomography (CT scan) is used more often in dogs and cats than in large animals due to their small size and ease of manipulation. This paper, however, illustrates the use of the technique in horses. CT scan was used in the diagnosis of two conditions of the head and limbs, namely alveolar ...

  15. Lysosomal storage diseases: current diagnostic and therapeutic options

    International Nuclear Information System (INIS)

    Malinova, V.; Honzik, T.

    2013-01-01

    Lysosomal storage diseases are rare genetic diseases caused by insufficient activity of some of the lysosomal enzymes and/or transport proteins. Initial symptoms may appear any time from the neonatal period to late adulthood; early forms tend to have a severe course with rapid progression and unfavorable prognosis. There is multisystem involvement with continuous progression of symptoms and involvement of metabolically active organs or tissues – the bone marrow, liver, bones, skeletal muscles, myocardium, or CNS. The diagnosis is definitively confirmed by demonstration of reduced activity of the particular enzyme and by mutation analysis. Some of the storage diseases can be effectively treated by intravenous administration of recombinant enzymes or by limiting the amount of the substrate stored. In a small number of lysosomal storage diseases, bone marrow transplantation is successful. Multidisciplinary collaboration, including genetic counselling and prenatal diagnosis in patient families, is required. The first part of the paper deals with general characteristics of lysosomal storage diseases and the most common diseases that are currently treatable in the Czech Republic (Gaucher’s disease, Pompe disease, Fabry disease, Niemann–Pick disease, cholesterol ester storage disease). The second part of the paper deals with mucopolysaccharidase, another group of rare lysosomal storage diseases. (author)

  16. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding...... the basic technique involved, sampling, efficiency, and reproducibility. Various types of cancers, where stereologic grading of malignancy has been used, are reviewed and discussed with regard to the development of a new objective and reproducible basis for carrying out prognosis-related malignancy grading...

  17. Lithium-ion battery diagnostic and prognostic techniques

    Science.gov (United States)

    Singh, Harmohan N.

    2009-11-03

    Embodiments provide a method and a system for determining cell imbalance condition of a multi-cell battery including a plurality of cell strings. To determine a cell imbalance condition, a charge current is applied to the battery and is monitored during charging. The charging time for each cell string is determined based on the monitor of the charge current. A charge time difference of any two cell strings in the battery is used to determine the cell imbalance condition by comparing with a predetermined acceptable charge time difference for the cell strings.

  18. Diagnostic analysis of vibration signals using adaptive digital filtering techniques

    Science.gov (United States)

    Jewell, R. E.; Jones, J. H.; Paul, J. E.

    1983-01-01

    Signal enhancement techniques are described using recently developed digital adaptive filtering equipment. Adaptive filtering concepts are not new; however, as a result of recent advances in microprocessor-based electronics, hardware has been developed that has stable characteristics and of a size exceeding 1000th order. Selected data processing examples are presented illustrating spectral line enhancement, adaptive noise cancellation, and transfer function estimation in the presence of corrupting noise.

  19. Development of fault diagnostic technique using reactor noise analysis

    International Nuclear Information System (INIS)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B.

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  20. Development of fault diagnostic technique using reactor noise analysis

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jin Ho; Kim, J. S.; Oh, I. S.; Ryu, J. S.; Joo, Y. S.; Choi, S.; Yoon, D. B

    1999-04-01

    The ultimate goal of this project is to establish the analysis technique to diagnose the integrity of reactor internals using reactor noise. The reactor noise analyses techniques for the PWR and CANDU NPP(Nuclear Power Plants) were established by which the dynamic characteristics of reactor internals and SPND instrumentations could be identified, and the noise database corresponding to each plant(both Korean and foreign one) was constructed and compared. Also the change of dynamic characteristics of the Ulchin 1 and 2 reactor internals were simulated under presumed fault conditions. Additionally portable reactor noise analysis system was developed so that real time noise analysis could directly be able to be performed at plant site. The reactor noise analyses techniques developed and the database obtained from the fault simulation, can be used to establish a knowledge based expert system to diagnose the NPP's abnormal conditions. And the portable reactor noise analysis system may be utilized as a substitute for plant IVMS(Internal Vibration Monitoring System). (author)

  1. Diagnostics of gas behind shock waves by refractive optical techniques

    International Nuclear Information System (INIS)

    Blaha, J.

    In a brief outline of optical methods for measuring neutral gas and plasma parameters, techniques are specifically dealt with based on the interferometric measurement of the refractive index. The investigation is shown of gas density changes in a shock tube using the optical Mach-Zehnder interferometer. While in a neutral gas the refractive index is determined by gas density, in a plasma the effects of all components, ie., electrons, ions and atoms are additive. The contributions to refraction from the various components may, in view of the different character and frequencies of the components, be resolved by measurement on more than one wavelength. (J.U.)

  2. Analysis of diagnostic calorimeter data by the transfer function technique

    Energy Technology Data Exchange (ETDEWEB)

    Delogu, R. S., E-mail: rita.delogu@igi.cnr.it; Pimazzoni, A.; Serianni, G. [Consorzio RFX, Corso Stati Uniti, 35127 Padova (Italy); Poggi, C.; Rossi, G. [Università degli Studi di Padova, Via 8 Febbraio 1848, 35122 Padova (Italy)

    2016-02-15

    This paper describes the analysis procedure applied to the thermal measurements on the rear side of a carbon fibre composite calorimeter with the purpose of reconstructing the energy flux due to an ion beam colliding on the front side. The method is based on the transfer function technique and allows a fast analysis by means of the fast Fourier transform algorithm. Its efficacy has been tested both on simulated and measured temperature profiles: in all cases, the energy flux features are well reproduced and beamlets are well resolved. Limits and restrictions of the method are also discussed, providing strategies to handle issues related to signal noise and digital processing.

  3. Defect detection in conducting materials using eddy current testing techniques

    Directory of Open Access Journals (Sweden)

    Brauer Hartmut

    2014-01-01

    Full Text Available Lorentz force eddy current testing (LET is a novel nondestructive testing technique which can be applied preferably to the identification of internal defects in nonmagnetic moving conductors. The LET is compared (similar testing conditions with the classical eddy current testing (ECT. Numerical FEM simulations have been performed to analyze the measurements as well as the identification of internal defects in nonmagnetic conductors. The results are compared with measurements to test the feasibility of defect identification. Finally, the use of LET measurements to estimate of the electrical conductors under test are described as well.

  4. Radiotherapy in prostate cancer. Innovative techniques and current controversies

    Energy Technology Data Exchange (ETDEWEB)

    Geinitz, Hans [Krankenhaus der Barmherzigen Schwestern, Linz (Austria). Dept. of Radiation Oncology; Linz Univ. (Austria). Medical Faculty; Roach, Mack III [California Univ., San Francisco, CA (United States). Dept. of Radiation Oncology; Van As, Nicholas (ed.) [The Institute of Cancer Research, Sutton Surrey (United Kingdom)

    2015-04-01

    Examines in detail the role of innovative radiation techniques in the management of prostate cancer, including IMRT, IGRT, BART, and modern brachytherapy. Explores a range of current controversies in patient treatment. Intended for both radiation oncologists and urologists. Radiation treatment is rapidly evolving owing to the coordinated research of physicists, engineers, computer and imaging specialists, and physicians. Today, the arsenal of ''high-precision'' or ''targeted'' radiotherapy includes multimodal imaging, in vivo dosimetry, Monte Carlo techniques for dose planning, patient immobilization techniques, intensity-modulated radiotherapy (IMRT), image-guided radiotherapy (IGRT), biologically adapted radiotherapy (BART), quality assurance methods, novel methods of brachytherapy, and, at the far end of the scale, particle beam radiotherapy using protons and carbon ions. These approaches are like pieces of a puzzle that need to be put together to provide the prostate cancer patient with high-level optimized radiation treatment. This book examines in detail the role of the above-mentioned innovative radiation techniques in the management of prostate cancer. In addition, a variety of current controversies regarding treatment are carefully explored, including whether prophylactic treatment of the pelvic lymphatics is essential, the magnitude of the effect of dose escalation, whether a benefit accrues from hypofractionation, and what evidence exists for the superiority of protons or heavy ions. Radiotherapy in Prostate Cancer: Innovative Techniques and Current Controversies is intended for both radiation oncologists and urologists with an interest in the up-to-date capabilities of modern radiation oncology for the treatment of prostate cancer.

  5. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  6. The influence on finite measurement accuracy on the SWE-to-PWE antenna diagnostics technique

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Breinbjerg, Olav; Frandsen, Aksel

    2006-01-01

    A new antenna diagnostics technique based on the transformation of the spherical wave expansion (SWE) into the plane wave expansion (PWE) is proposed. The new technique allows the recovery of the plane wave spectrum in the visible region, and in principle also in part of the invisible region, from...

  7. Current STR-based techniques in forensic science

    Directory of Open Access Journals (Sweden)

    Phuvadol Thanakiatkrai

    2013-01-01

    Full Text Available DNA analysis in forensic science is mainly based on short tandem repeat (STR genotyping. The conventional analysis is a three-step process of DNA extraction, amplification and detection. An overview of various techniques that are currently in use and are being actively researched for STR typing is presented. The techniques are separated into STR amplification and detection. New techniques for forensic STR analysis focus on increasing sensitivity, resolution and discrimination power for suboptimal samples. These are achieved by shifting primer-binding sites, using high-fidelity and tolerant polymerases and applying novel methods to STR detection. Examples in which STRs are used in criminal investigations are provided and future research directions are discussed.

  8. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A. [KFKI-AEKI Applied Reactor Physics, Budapest (Hungary); Pazsit, I. [Chalmers Univ. of Tech., Goeteborg (Sweden). Dept. of Reactor Physics

    1997-12-08

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source code written in MATLAB are available at a public ftp site. The necessary information to reproduce the simulation results is also reported. (author).

  9. Diagnostics of detector tube impacting with wavelet techniques

    Energy Technology Data Exchange (ETDEWEB)

    Racz, A.; Pazsit, I

    1998-04-01

    A neutron noise based method is proposed for the detection of impacting of detector tubes in BWRs. The basic idea relies on the assumption that non-stationary transients (e.g. fuel box vibrations) may be induced at impacting. Such short-lived transients are difficult to detect by spectral analysis methods. However, their presence in the detector signal can be detected by wavelet analysis. A simple wavelet technique, the so-called Haar transform, is suggested for the detection of impacting. Tests of the proposed method have been performed with success on both simulated data with controlled impacting as well as with real measurement data. The simulation model as well as the results of the wavelet analysis are reported in this paper. The source codes written in MATLAB[reg] are available at a public ftp site. The necessary information to reproduce the simulation results is also reported.

  10. Mild cognitive impairment. Diagnostic value of different MR techniques

    International Nuclear Information System (INIS)

    Hauser, T.; Stieltjes, B.; Essig, M.; Thomann, P.A.

    2011-01-01

    In view of an increasingly aging population the prevalence of dementia is also expected to increase rapidly. As well as clinical, neuropsychological and laboratory procedures magnetic resonance imaging (MRI) plays an important role in the early diagnosis of dementia which is important in the precursor stage of mild cognitive impairment (MCI). On the one hand this stage is associated with an increased risk of dementia and on the other hand an early treatment in this stage could attenuate development of the disease. In addition to morphological changes different functional MRI techniques can help in the early diagnosis of dementia and the precursor stages. Moreover, it is important to detect those MCI patients who are at particularly risk for developing dementia. In the differentiation of converters to non-converters initial studies suggest that particularly voxel-based morphometry, MR spectroscopy and diffusion tensor imaging can provide important additional information. (orig.) [de

  11. Unbiased stereologic techniques for practical use in diagnostic histopathology

    DEFF Research Database (Denmark)

    Sørensen, Flemming Brandt

    1995-01-01

    by introducing quantitative techniques in the histopathologic discipline of malignancy grading. Unbiased stereologic methods, especially based on measurements of nuclear three-dimensional mean size, have during the last decade proved their value in this regard. In this survey, the methods are reviewed regarding......Grading of malignancy by the examination of morphologic and cytologic details in histologic sections from malignant neoplasms is based exclusively on qualitative features, associated with significant subjectivity, and thus rather poor reproducibility. The traditional way of malignancy grading may...... of solid tumors. This new, unbiased attitude to malignancy grading is associated with excellent virtues, which ultimately may help the clinician in the choice of optimal treatment of the individual patient suffering from cancer. Stereologic methods are not solely applicable to the field of malignancy...

  12. [THE CYTOMETRIC TECHNIQUE OF BINDING OF EOSIN-5-MALEIMIDE IN DIAGNOSTIC OF INHERENT SPHEROCYTOSIS].

    Science.gov (United States)

    Kuzminova, J A; Plyasunova, S A; Jogov, V V; Smetanina, N S

    2016-03-01

    The laboratory diagnostic of inherent spherocytosis is based on detection of spherocytes in peripheral blood, decreasing of index of sphericity, decreasing of osmotic resistance of erythrocytes. The new test of diagnostic of hereditary spherocytosis build on molecular defect was developed on the basis of binding extracellular fragments of protein of band 3 with eosin-5-maleimide (EMA-test). The study was carried out to implement comparative analysis of sensitivity and specificity of techniques applied to diagnose inherent spherocytosis. The sampling of 94 patients with various forms of anemias was analyzed All patients were applied complex clinical laboratory examination including analysis of osmotic resistance of erythrocytes, erythrocytometry and EMA-test as specific techniques of diagnostic of inherent spherocytosis. In 51 out of 94 patients (54%) decreasing of values of EMA-test was detected and in 47 patients diagnosis of inherent spherocytosis was confirmed. The standard values of EMA-test were established in 43 patients (46%) and 12 patients out of them with established diagnosis of inherent spherocytosis. Therefore, sensitivity of EMA-test made up to 79% and specificity - 80%. The most sensitive techniques of diagnostic remain osmotic resistance of erythrocytes (91%) and index of sphericity (up to 96%). But the highest specificity in this respect has EMA-test (80%). Nowadays, none of implemented techniques of diagnostic of inherent spherocytosis can be applied as a universal one. The implementation of complex examination is needed for proper diagnostic of disease.

  13. The pulses as a diagnostic technique in the sun

    International Nuclear Information System (INIS)

    Das, G.C.

    1980-01-01

    In this paper we discuss a method of finding physical parameters by studying the pulses in the Sun. For the sake of a mathematical approach, we consider an ideal, highly relevant model which could exist in the Sun with the effects of ionization, due to which there will be a continuous formation of ionized particles. It is observed that the pulse originated at the centre of a dipole field propagates along the magnetic field. We derive a dispersion relation for these types of pulses, propagating from the centre to the solar surface. The time taken by the pulse from its source to the solar surface is also estimated, with due account of the ionization effects on the pulse. Without proper account of these effects, the technique employed in determing the physical parameters may lead to error. Temporal and spatial damping of the pulses lead to estimates of the velocity distribution of the ionized particles and of the amplitude of the magnetic field of the wave in pulse. (orig.)

  14. A Hybrid Neural Network-Genetic Algorithm Technique for Aircraft Engine Performance Diagnostics

    Science.gov (United States)

    Kobayashi, Takahisa; Simon, Donald L.

    2001-01-01

    In this paper, a model-based diagnostic method, which utilizes Neural Networks and Genetic Algorithms, is investigated. Neural networks are applied to estimate the engine internal health, and Genetic Algorithms are applied for sensor bias detection and estimation. This hybrid approach takes advantage of the nonlinear estimation capability provided by neural networks while improving the robustness to measurement uncertainty through the application of Genetic Algorithms. The hybrid diagnostic technique also has the ability to rank multiple potential solutions for a given set of anomalous sensor measurements in order to reduce false alarms and missed detections. The performance of the hybrid diagnostic technique is evaluated through some case studies derived from a turbofan engine simulation. The results show this approach is promising for reliable diagnostics of aircraft engines.

  15. Development of technique for diagnostics of social reserves of development of collective labour potential

    OpenAIRE

    Голубєв, Станіслав Миколайович

    2015-01-01

    The problems of diagnostics of social reserves of the collective labour potential are considered in the article. The aim of this study is to develop diagnostic techniques of social reserves of the collective labour potential in the work and the essence of the concept of "social reserves" as a subject of study of economics and their features in the study of collective labour potential. The use of these reserves can increase the efficiency of the labour collective processes by improving coopera...

  16. Case-based reasoning diagnostic technique based on multi-attribute similarity

    Energy Technology Data Exchange (ETDEWEB)

    Makoto, Takahashi [Tohoku University, Miyagi (Japan); Akio, Gofuku [Okayama University, Okayamaa (Japan)

    2014-08-15

    Case-based diagnostic technique has been developed based on the multi-attribute similarity. Specific feature of the developed system is to use multiple attributes of process signals for similarity evaluation to retrieve a similar case stored in a case base. The present technique has been applied to the measurement data from Monju with some simulated anomalies. The results of numerical experiments showed that the present technique can be utilizes as one of the methods for a hybrid-type diagnosis system.

  17. Eddy current techniques for super duplex stainless steel characterization

    International Nuclear Information System (INIS)

    Camerini, C.; Sacramento, R.; Areiza, M.C.; Rocha, A.; Santos, R.; Rebello, J.M.; Pereira, G.

    2015-01-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content. - Highlights: • Sigma phase precipitation, even for low amounts, dramatically affects SDSS properties. • SDSS samples were thermally treated and carefully characterized by X-Ray Diffraction. • NDT techniques detected low amounts of sigma phase in SDSS microstructure

  18. Eddy current techniques for super duplex stainless steel characterization

    Energy Technology Data Exchange (ETDEWEB)

    Camerini, C., E-mail: cgcamerini@metalmat.ufrj.br [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil); Sacramento, R.; Areiza, M.C.; Rocha, A. [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil); Santos, R. [PETROBRAS R& D Center, Rio de Janeiro (Brazil); Rebello, J.M.; Pereira, G. [Laboratory of Non-Destructive Testing, Corrosion and Welding, Department of Metallurgical and Materials Engineering, Federal University of Rio de Janeiro (Brazil)

    2015-08-15

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content. - Highlights: • Sigma phase precipitation, even for low amounts, dramatically affects SDSS properties. • SDSS samples were thermally treated and carefully characterized by X-Ray Diffraction. • NDT techniques detected low amounts of sigma phase in SDSS microstructure.

  19. Current techniques for the investigation of vulnerable atherosclerotic plaques

    International Nuclear Information System (INIS)

    Riou, L.; Broisat, A.; Fagret, D.; Ghezzi, C.

    2005-01-01

    Atherosclerosis is the single most important contributor to cardiovascular diseases, the leading cause of death in industrialized countries. Atherosclerosis complications such as vulnerable coronary plaque rupture or erosion result in acute coronary events, i.e. myocardial infarction and sudden death. Vulnerable plaques initially develop eccentrically without impeding on the vessel lumen and are therefore not detectable using angiography. New techniques for the investigation of vulnerable plaques are needed to identify and treat vulnerable patients. Invasive techniques require the use of intracoronary probes and are thereby not applicable to large populations of patients. Intravascular ultrasound (IVUS) and optical coherence tomography (OCT) are the most promising invasive modalities. They provide morphological data that could potentially be associated with a more functional approach such as thermography, elasto-graphy, or spectroscopy, Non-invasive techniques are better suited for studying larger populations of patients. Computed tomography is currently used for calcium scoring, but the biological meaning and the prognostic value of this index remain to be fully determined. Non-invasive coronary magnetic resonance imaging (MRI) faces numerous technical challenges, and it essentially provides morphological data. Molecular nuclear imaging offers a great sensitivity and the ability to provide metabolic data about atherosclerotic lesions. New potential tracers of vulnerable plaques are currently being evaluated. Nuclear Medicine should therefore play a major role in the future as a non invasive imaging modality for the assessment of vulnerable atherosclerotic plaques. (author)

  20. Evaluation of techniques for inspection and diagnostics of HWR pressure tubes

    International Nuclear Information System (INIS)

    Choi, Jong-Ho

    2008-01-01

    Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes for Heavy Water Reactors (HWRs), are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. The objective of the CRP was to inter-compare inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of the CRP, participants investigated the capability of different techniques to detect and characterize flaws. During the second phase, participants collaborated to determine the hydrogen concentration and to detect and characterize hydride blisters in zirconium alloy pressure tubes. Eight organizations from six countries, which operate HWRs, have participated in this CRP, Most of the techniques examined are well established and many of them are regularly used during in-service inspection of pressure tubes. The inter-comparison of these techniques provides a platform for identifying a particular technique (or a set of techniques), which is more accurate and reliable as compared to others for a specified task. The CRP also witnessed some new methodologies, which can be implemented on in-service inspection tools. These new techniques could complement the existing ones to overcome their limitations, thereby improving the reliability and accuracy of in-service inspection. This CRP also identified future areas of research and development. (author)

  1. Mass spectrometry based proteomics profiling as diagnostic tool in oncology: current status and future perspective.

    Science.gov (United States)

    Findeisen, Peter; Neumaier, Michael

    2009-01-01

    Proteomics analysis has been heralded as a novel tool for identifying new and specific biomarkers that may improve diagnosis and monitoring of various disease states. Recent years have brought a number of proteomics profiling technologies. Although proteomics profiling has resulted in the detection of disease-associated differences and modification of proteins, current proteomics technologies display certain limitations that are hampering the introduction of these new technologies into clinical laboratory diagnostics and routine applications. In this review, we summarize current advances in mass spectrometry based biomarker discovery. The promises and challenges of this new technology are discussed with particular emphasis on diagnostic perspectives of mass-spectrometry based proteomics profiling for malignant diseases.

  2. Principle of the electrically induced Transient Current Technique

    Science.gov (United States)

    Bronuzzi, J.; Moll, M.; Bouvet, D.; Mapelli, A.; Sallese, J. M.

    2018-05-01

    In the field of detector development for High Energy Physics, the so-called Transient Current Technique (TCT) is used to characterize the electric field profile and the charge trapping inside silicon radiation detectors where particles or photons create electron-hole pairs in the bulk of a semiconductor device, as PiN diodes. In the standard approach, the TCT signal originates from the free carriers generated close to the surface of a silicon detector, by short pulses of light or by alpha particles. This work proposes a new principle of charge injection by means of lateral PN junctions implemented in one of the detector electrodes, called the electrical TCT (el-TCT). This technique is fully compatible with CMOS technology and therefore opens new perspectives for assessment of radiation detectors performances.

  3. Novel Treponema pallidum Recombinant Antigens for Syphilis Diagnostics: Current Status and Future Prospects

    Directory of Open Access Journals (Sweden)

    Aleksey Kubanov

    2017-01-01

    Full Text Available The recombinant protein technology considerably promoted the development of rapid and accurate treponema-specific laboratory diagnostics of syphilis infection. For the last ten years, the immunodominant recombinant inner membrane lipoproteins are proved to be sensitive and specific antigens for syphilis screening. However, the development of an enlarged T. pallidum antigen panel for diagnostics of early and late syphilis and differentiation of syphilis stages or cured syphilis remains as actual goal of multidisciplinary expertise. Current review revealed novel recombinant antigens: surface-exposed proteins, adhesins, and periplasmic and flagellar proteins, which are promising candidates for the improved syphilis serological diagnostics. The opportunities and limitations of diagnostic usage of these antigens are discussed and the criteria for selection of optimal antigens panel summarized.

  4. Novel Treponema pallidum Recombinant Antigens for Syphilis Diagnostics: Current Status and Future Prospects.

    Science.gov (United States)

    Kubanov, Aleksey; Runina, Anastassia; Deryabin, Dmitry

    2017-01-01

    The recombinant protein technology considerably promoted the development of rapid and accurate treponema-specific laboratory diagnostics of syphilis infection. For the last ten years, the immunodominant recombinant inner membrane lipoproteins are proved to be sensitive and specific antigens for syphilis screening. However, the development of an enlarged T. pallidum antigen panel for diagnostics of early and late syphilis and differentiation of syphilis stages or cured syphilis remains as actual goal of multidisciplinary expertise. Current review revealed novel recombinant antigens: surface-exposed proteins, adhesins, and periplasmic and flagellar proteins, which are promising candidates for the improved syphilis serological diagnostics. The opportunities and limitations of diagnostic usage of these antigens are discussed and the criteria for selection of optimal antigens panel summarized.

  5. Targeted therapies with companion diagnostics in the management of breast cancer: current perspectives.

    Science.gov (United States)

    Myers, Meagan B

    2016-01-01

    Breast cancer is a multifaceted disease exhibiting both intertumoral and intratumoral heterogeneity as well as variable disease course. Over 2 decades of research has advanced the understanding of the molecular substructure of breast cancer, directing the development of new therapeutic strategies against these actionable targets. In vitro diagnostics, and specifically companion diagnostics, have been integral in the successful development and implementation of these targeted therapies, such as those directed against the human epidermal growth factor receptor 2. Lately, there has been a surge in the development, commercialization, and marketing of diagnostic assays to assist in breast cancer patient care. More recently, multigene signature assays, such as Oncotype DX, MammaPrint, and Prosigna, have been integrated in the clinical setting in order to tailor decisions on adjuvant endocrine and chemotherapy treatment. This review provides an overview of the current state of breast cancer management and the use of companion diagnostics to direct personalized approaches in the treatment of breast cancer.

  6. Applying inversion techniques to derive source currents and geoelectric fields for geomagnetically induced current calculations

    Directory of Open Access Journals (Sweden)

    J. S. de Villiers

    2014-10-01

    Full Text Available This research focuses on the inversion of geomagnetic variation field measurement to obtain source currents in the ionosphere. During a geomagnetic disturbance, the ionospheric currents create magnetic field variations that induce geoelectric fields, which drive geomagnetically induced currents (GIC in power systems. These GIC may disturb the operation of power systems and cause damage to grounded power transformers. The geoelectric fields at any location of interest can be determined from the source currents in the ionosphere through a solution of the forward problem. Line currents running east–west along given surface position are postulated to exist at a certain height above the Earth's surface. This physical arrangement results in the fields on the ground having the magnetic north and down components, and the electric east component. Ionospheric currents are modelled by inverting Fourier integrals (over the wavenumber of elementary geomagnetic fields using the Levenberg–Marquardt technique. The output parameters of the inversion model are the current strength, height and surface position of the ionospheric current system. A ground conductivity structure with five layers from Quebec, Canada, based on the Layered-Earth model is used to obtain the complex skin depth at a given angular frequency. This paper presents preliminary and inversion results based on these structures and simulated geomagnetic fields. The results show some interesting features in the frequency domain. Model parameters obtained through inversion are within 2% of simulated values. This technique has applications for modelling the currents of electrojets at the equator and auroral regions, as well as currents in the magnetosphere.

  7. Eddy current techniques for super duplex stainless steel characterization

    Science.gov (United States)

    Camerini, C.; Sacramento, R.; Areiza, M. C.; Rocha, A.; Santos, R.; Rebello, J. M.; Pereira, G.

    2015-08-01

    Super duplex stainless steel (SDSS) is a two-phase material where the microstructure consists of grains of ferrite (δ) and austenite (γ). SDSS exhibit an attractive combination of properties, such as: strength, toughness and stress corrosion cracking resistance. Nevertheless, SDSS attain these properties after a controlled solution heat treatment, leading to a similar volumetric fraction of δ and γ. Any further heat treatment, welding operation for example, can change the balance of the original phases, or may also lead to precipitation of a deleterious phase, such as sigma (σ). For these situations, the material corrosion resistance is severely impaired. In the present study, several SDSS samples with low σ phase content and non-balanced microstructure were intentionally obtained by thermally treating SDSS specimens. Electromagnetic techniques, conventional Eddy Current Testing (ECT) and Saturated Low Frequency Eddy Current (SLOFEC), were employed to characterize the SDSS samples. The results showed that ECT and SLOFEC are reliable techniques to evaluate σ phase presence in SDSS and can provide an estimation of the δ content.

  8. Motor current and leakage flux signature analysis technique for condition monitoring

    International Nuclear Information System (INIS)

    Pillai, M.V.; Moorthy, R.I.K.; Mahajan, S.C.

    1994-01-01

    Till recently analysis of vibration signals was the only means available to predict the state of health of plant equipment. Motor current and leakage magnetic flux signature analysis is acquiring importance as a technique for detection of incipient damages in the electrical machines and as a supplementary technique for diagnostics of driven equipment such as centrifugal and reciprocating pumps. The state of health of the driven equipment is assessed by analysing time signal, frequency spectrum and trend analysis. For example, the pump vane frequency, piston stroke frequency, gear frequency and bearing frequencies are indicated in the current and flux spectra. By maintaining a periodic record of the amplitudes of various frequency lines in the frequency spectra, it is possible to understand the trend of deterioration of parts and components of the pump. All problems arising out of inappropriate mechanical alignment of vertical pumps are easily identified by a combined analysis of current, flux and vibration signals. It is found that current signature analysis technique is a sufficient method in itself for the analysis of state of health of reciprocating pumps and compressors. (author). 10 refs., 4 figs

  9. Modeling of novel diagnostic strategies for active tuberculosis - a systematic review: current practices and recommendations.

    Directory of Open Access Journals (Sweden)

    Alice Zwerling

    Full Text Available The field of diagnostics for active tuberculosis (TB is rapidly developing. TB diagnostic modeling can help to inform policy makers and support complicated decisions on diagnostic strategy, with important budgetary implications. Demand for TB diagnostic modeling is likely to increase, and an evaluation of current practice is important. We aimed to systematically review all studies employing mathematical modeling to evaluate cost-effectiveness or epidemiological impact of novel diagnostic strategies for active TB.Pubmed, personal libraries and reference lists were searched to identify eligible papers. We extracted data on a wide variety of model structure, parameter choices, sensitivity analyses and study conclusions, which were discussed during a meeting of content experts.From 5619 records a total of 36 papers were included in the analysis. Sixteen papers included population impact/transmission modeling, 5 were health systems models, and 24 included estimates of cost-effectiveness. Transmission and health systems models included specific structure to explore the importance of the diagnostic pathway (n = 4, key determinants of diagnostic delay (n = 5, operational context (n = 5, and the pre-diagnostic infectious period (n = 1. The majority of models implemented sensitivity analysis, although only 18 studies described multi-way sensitivity analysis of more than 2 parameters simultaneously. Among the models used to make cost-effectiveness estimates, most frequent diagnostic assays studied included Xpert MTB/RIF (n = 7, and alternative nucleic acid amplification tests (NAATs (n = 4. Most (n = 16 of the cost-effectiveness models compared new assays to an existing baseline and generated an incremental cost-effectiveness ratio (ICER.Although models have addressed a small number of important issues, many decisions regarding implementation of TB diagnostics are being made without the full benefits of insight from mathematical

  10. Resolution of effects in multi-frequency eddy current data for reliable diagnostics of conductive materials

    DEFF Research Database (Denmark)

    Egorov, Alexander; Kucheryavskiy, Sergey V.; Polyakov, Viktor

    2017-01-01

    The effect of eddy currents is widely used for diagnostics of conductive materials. It allows to create very simple and inexpensive systems for non-destructive measurements. However, the results of the measurements depend on many factors, including first of all, a conductivity of material...

  11. The radiation protection optimisation in contrast X-ray diagnostic techniques

    International Nuclear Information System (INIS)

    Markovic, S.; Pavlovic, R.

    1995-01-01

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit α. (author) 3 figs., 10 refs

  12. The radiation protection optimisation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In the class of artificial sources, X-ray diagnostic techniques irradiate global population with more than 90 % share in total dose. At the same time this is the only area with high possibilities in collective dose reduction without important investments. Exposure of the medical team is mainly related to unnecessary irradiation. Eliminating this unnecessary irradiation quality of diagnostic information remains undisturbed. From the radiation protection point of view the most critical X-ray diagnostic method is angiography. This paper presents the radiation protection optimisation calculation of the protective lead thickness using the Cost - Benefit analysis technique. The obtained numerical results are based on calculated collective dose, the estimated prices of the lead and lead glass thickness and the adopted price for monetary value of the collective dose unit {alpha}. (author) 3 figs., 10 refs.

  13. The application of DECnet TTT technique in beam diagnostical system of SSC central region

    International Nuclear Information System (INIS)

    Zhang Guixu; Huang Tuanhua

    1997-01-01

    The DECnet TTT technique and the real time network communication based on DECnet TTT are presented. Information can be transferred between console and diagnostical system via DECnet communication, so all kinds of operation can be done on console. The working computer of HIRFL console is VAX8350

  14. New perineal injection technique for pudendal nerve infiltration in diagnostic and therapeutic procedures

    NARCIS (Netherlands)

    Weinschenk, Stefan; Hollmann, Markus W.; Strowitzki, Thomas

    2016-01-01

    Pudendal nerve injection is used as a diagnostic procedure in the vulvar region and for therapeutic purposes, such as in vulvodynia. Here, we provide a new, easy-to-perform perineal injection technique. We analyzed 105 perineal injections into the pudendal nerve with a local anesthetic (LA),

  15. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Additional information

    International Nuclear Information System (INIS)

    2009-03-01

    The reports from Argentina, Canada, India, Korea and Romania are presented concerning the projects carried out under the Coordinated Research Program (CRP) I3.30.10 of the International Agency for Atomic Energy - Vienna related to 'Intercomparison of Techniques for Pressure Tube Inspection and Diagnostics'

  16. 2D imaging X-ray diagnostic for measuring the current density distribution in a wide-area electron beam produced in a multiaperture diode with plasma cathode

    Science.gov (United States)

    Kurkuchekov, V.; Kandaurov, I.; Trunev, Y.

    2018-05-01

    A simple and inexpensive X-ray diagnostic tool was designed for measuring the cross-sectional current density distribution in a low-relativistic pulsed electron beam produced in a source based on an arc-discharge plasma cathode and multiaperture diode-type electron optical system. The beam parameters were as follows: Uacc = 50–110 kV, Ibeam = 20–100 A, τbeam = 0.1–0.3 ms. The beam effective diameter was ca. 7 cm. Based on a pinhole camera, the diagnostic allows one to obtain a 2D profile of electron beam flux distribution on a flat metal target in a single shot. The linearity of the diagnostic system response to the electron flux density was established experimentally. Spatial resolution of the diagnostic was also estimated in special test experiments. The optimal choice of the main components of the diagnostic technique is discussed.

  17. Emissions from heavy current carrying high density plasma and their diagnostics

    International Nuclear Information System (INIS)

    Hirano, Katsumi

    1987-06-01

    Workshop on ''Emissions from heavy current carrying high density plasma and diagnostics'' was held at Institute of Plasma Physics, Nagoya University on 3. and 4. December 1986 under a collaborating research Program. The workshop was attended by 43 researchers from 19 labolatories. A total of 22 papers were submitted and are presented in these proceedings. The largest group of papers was that on soft X-ray emission. It seems this topic is a foremost interest for groups which engaged in research of the Z pinch and the plasma focus. A variety of problems in pinched dense plasmas, namely spectroscopy, diagnostics, pinch dynamics, and related engineering aspects were also discussed. (author)

  18. Comparison of image quality and radiation dose between combined automatic tube current modulation and fixed tube current technique in CT of abdomen and pelvis

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Sanghee (Dept. of Radiology and Center for Imaging Science, Samsung Medical Center, Sungkyunkwan Univ. School of Medicine (Korea, Republic of)); Yoon, Sang-Wook; Yoo, Seung-Min; Kim, Kyoung Ah; Kim, Sang Heum; Lee, Jong Tae (Dept. of Diagnostic Radiology, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of)), email: jansons@cha.ac.kr; Ji, Young Geon (Preventive Medicine, CHA Bundang Medical Center, CHA Univ. (Korea, Republic of))

    2011-12-15

    Background. Tube current is an important determinant of radiation dose and image quality in X-ray-based examination. The combined automatic tube current modulation technique (ATCM) enables automatic adjustment of the tube current in various planes (x-y and z) based on the size and attenuation of the body area scanned. Purpose. To compare image quality and radiation dose of the ATCM with those of a fixed tube current technique (FTC) in CT of the abdomen and pelvis performed with a 16-slice multidetector row CT. Material and Methods. We reviewed 100 patients in whom initial and follow-up CT of the abdomen and pelvis were performed with FTC and ATCM. All acquisition parameters were identical in both techniques except for tube current. We recorded objective image noise in liver parenchyma, subjective image noise and diagnostic acceptability by using a five-point scale, radiation dose, and body mass index (BMI, kg/m2). Data were analyzed with parametric and non-parametric statistical tests. Results. There was no significant difference in image noise and diagnostic acceptability between two techniques. All subjects had acceptable subjective image noise in both techniques. The significant reduction in radiation dose (45.25% reduction) was noted with combined ATCM (P < 0.001). There was a significant linear statistical correlation between BMI and dose reduction (r = -0.78, P < 0.05). Conclusion. The ATCM for CT of the abdomen and pelvis substantially reduced radiation dose while maintaining diagnostic image quality. Patients with lower BMI showed more reduction in radiation dose

  19. Fungal disease detection in plants: Traditional assays, novel diagnostic techniques and biosensors.

    Science.gov (United States)

    Ray, Monalisa; Ray, Asit; Dash, Swagatika; Mishra, Abtar; Achary, K Gopinath; Nayak, Sanghamitra; Singh, Shikha

    2017-01-15

    Fungal diseases in commercially important plants results in a significant reduction in both quality and yield, often leading to the loss of an entire plant. In order to minimize the losses, it is essential to detect and identify the pathogens at an early stage. Early detection and accurate identification of pathogens can control the spread of infection. The present article provides a comprehensive overview of conventional methods, current trends and advances in fungal pathogen detection with an emphasis on biosensors. Traditional techniques are the "gold standard" in fungal detection which relies on symptoms, culture-based, morphological observation and biochemical identifications. In recent times, with the advancement of biotechnology, molecular and immunological approaches have revolutionized fungal disease detection. But the drawback lies in the fact that these methods require specific and expensive equipments. Thus, there is an urgent need for rapid, reliable, sensitive, cost effective and easy to use diagnostic methods for fungal pathogen detection. Biosensors would become a promising and attractive alternative, but they still have to be subjected to some modifications, improvements and proper validation for on-field use. Copyright © 2016 Elsevier B.V. All rights reserved.

  20. Advances in Current Rating Techniques for Flexible Printed Circuits

    Science.gov (United States)

    Hayes, Ron

    2014-01-01

    Twist Capsule Assemblies are power transfer devices commonly used in spacecraft mechanisms that require electrical signals to be passed across a rotating interface. Flexible printed circuits (flex tapes, see Figure 2) are used to carry the electrical signals in these devices. Determining the current rating for a given trace (conductor) size can be challenging. Because of the thermal conditions present in this environment the most appropriate approach is to assume that the only means by which heat is removed from the trace is thru the conductor itself, so that when the flex tape is long the temperature rise in the trace can be extreme. While this technique represents a worst-case thermal situation that yields conservative current ratings, this conservatism may lead to overly cautious designs when not all traces are used at their full rated capacity. A better understanding of how individual traces behave when they are not all in use is the goal of this research. In the testing done in support of this paper, a representative flex tape used for a flight Solar Array Drive Assembly (SADA) application was tested by energizing individual traces (conductors in the tape) in a vacuum chamber and the temperatures of the tape measured using both fine-gauge thermocouples and infrared thermographic imaging. We find that traditional derating schemes used for bundles of wires do not apply for the configuration tested. We also determine that single active traces located in the center of a flex tape operate at lower temperatures than those on the outside edges.

  1. On-line diagnostic techniques for air-operated control valves based on time series analysis

    International Nuclear Information System (INIS)

    Ito, Kenji; Matsuoka, Yoshinori; Minamikawa, Shigeru; Komatsu, Yasuki; Satoh, Takeshi.

    1996-01-01

    The objective of this research is to study the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves - numerous valves of the type which are used in PWR plants. Generally the techniques can detect anomalies by failures in the initial stages for which detection is difficult by conventional surveillance of process parameters measured directly. However, the effectiveness of these techniques depends on the system being diagnosed. The difficulties in applying diagnostic techniques to air-operated control valves seem to come from the reduced sensitivity of their response as compared with hydraulic control systems, as well as the need to identify anomalies in low level signals that fluctuate only slightly but continuously. In this research, simulation tests were performed by setting various kinds of failure modes for a test valve with the same specifications as of a valve actually used in the plants. Actual control signals recorded from an operating plant were then used as input signals for simulation. The results of the tests confirmed the feasibility of applying on-line diagnostic techniques based on time series analysis to air-operated control valves. (author)

  2. Advanced Laser-Based Techniques for Gas-Phase Diagnostics in Combustion and Aerospace Engineering.

    Science.gov (United States)

    Ehn, Andreas; Zhu, Jiajian; Li, Xuesong; Kiefer, Johannes

    2017-03-01

    Gaining information of species, temperature, and velocity distributions in turbulent combustion and high-speed reactive flows is challenging, particularly for conducting measurements without influencing the experimental object itself. The use of optical and spectroscopic techniques, and in particular laser-based diagnostics, has shown outstanding abilities for performing non-intrusive in situ diagnostics. The development of instrumentation, such as robust lasers with high pulse energy, ultra-short pulse duration, and high repetition rate along with digitized cameras exhibiting high sensitivity, large dynamic range, and frame rates on the order of MHz, has opened up for temporally and spatially resolved volumetric measurements of extreme dynamics and complexities. The aim of this article is to present selected important laser-based techniques for gas-phase diagnostics focusing on their applications in combustion and aerospace engineering. Applicable laser-based techniques for investigations of turbulent flows and combustion such as planar laser-induced fluorescence, Raman and Rayleigh scattering, coherent anti-Stokes Raman scattering, laser-induced grating scattering, particle image velocimetry, laser Doppler anemometry, and tomographic imaging are reviewed and described with some background physics. In addition, demands on instrumentation are further discussed to give insight in the possibilities that are offered by laser flow diagnostics.

  3. Mini-FLOTAC, an innovative direct diagnostic technique for intestinal parasitic infections: experience from the field.

    Science.gov (United States)

    Barda, Beatrice Divina; Rinaldi, Laura; Ianniello, Davide; Zepherine, Henry; Salvo, Fulvio; Sadutshang, Tsetan; Cringoli, Giuseppe; Clementi, Massimo; Albonico, Marco

    2013-01-01

    Soil-transmitted helminths and intestinal protozoa infection are widespread in developing countries, yet an accurate diagnosis is rarely performed. The aim of this study was to evaluate the recently developed mini-FLOTAC method and to compare with currently more widely used techniques for the diagnosis of intestinal parasitic infections in different settings. The study was carried out in Dharamsala, Himachal Pradesh, India, and in Bukumbi, Tanzania. A total of 180 pupils from two primary schools had their stool analyzed (n = 80 in Dharamsala and n = 100 in Bukumbi) for intestinal parasitic infections with three diagnostic methods: direct fecal smear, formol-ether concentration method (FECM) and mini-FLOTAC. Overall, 72% of the pupils were positive for any intestinal parasitic infection, 24% carried dual infections and 11% three infections or more. The most frequently encountered intestinal parasites were Entamoeba coli, Entamoeba histolytica/dispar, Giardia intestinalis, hookworm, (and Schistosoma mansoni, in Tanzania). Statistically significant differences were found in the detection of parasitic infections among the three methods: mini-FLOTAC was the most sensitive method for helminth infections (90% mini-FLOTAC, 60% FECM, and 30% direct fecal smear), whereas FECM was most sensitive for intestinal protozoa infections (88% FECM, 70% direct fecal smear, and 68% mini-FLOTAC). We present the first experiences with the mini-FLOTAC for the diagnosis of intestinal helminths and protozoa. Our results suggest that it is a valid, sensitive and potentially low-cost alternative technique that could be used in resource-limited settings--particularly for helminth diagnosis.

  4. Kinetic and Diagnostic Studies of Molecular Plasmas Using Laser Absorption Techniques

    International Nuclear Information System (INIS)

    Welzel, S; Rousseau, A; Davies, P B; Roepcke, J

    2007-01-01

    Within the last decade mid infrared absorption spectroscopy between 3 and 20 μm, known as Infrared Laser Absorption Spectroscopy (IRLAS) and based on tuneable semiconductor lasers, namely lead salt diode lasers, often called tuneable diode lasers (TDL), and quantum cascade lasers (QCL) has progressed considerably as a powerful diagnostic technique for in situ studies of the fundamental physics and chemistry of molecular plasmas. The increasing interest in processing plasmas containing hydrocarbons, fluorocarbons, organo-silicon and boron compounds has lead to further applications of IRLAS because most of these compounds and their decomposition products are infrared active. IRLAS provides a means of determining the absolute concentrations of the ground states of stable and transient molecular species, which is of particular importance for the investigation of reaction kinetics. Information about gas temperature and population densities can also be derived from IRLAS measurements. A variety of free radicals and molecular ions have been detected, especially using TDLs. Since plasmas with molecular feed gases are used in many applications such as thin film deposition, semiconductor processing, surface activation and cleaning, and materials and waste treatment, this has stimulated the adaptation of infrared spectroscopic techniques to industrial requirements. The recent development of QCLs offers an attractive new option for the monitoring and control of industrial plasma processes as well as for highly time-resolved studies on the kinetics of plasma processes. The aim of the present article is threefold: (i) to review recent achievements in our understanding of molecular phenomena in plasmas (ii) to report on selected studies of the spectroscopic properties and kinetic behaviour of radicals, and (iii) to describe the current status of advanced instrumentation for TDLAS in the mid infrared

  5. Imaging nuclear medicine techniques for diagnostic evaluation of arterial hypertension. Bildgebende nuklearmedizinische Diagnostik bei arterieller Hypertonie

    Energy Technology Data Exchange (ETDEWEB)

    Eisenberg, B M; Linss, G

    1989-01-01

    Arterial hypertension may be caused by a malfunction of organs and in turn may lead to secondary organic lesions. Modern diagnostic nuclear medicine is applied for function studies in order to detect or exclude secondary hypertension and functional or perfusion disturbances due to hypertension, or to assess and follow up hemodynamic conditions and cardiac functions prior to and during therapy. The article presents a survey of imaging diagnostic nuclear medicine techniques for the eamination of the heart, the brain, the kidneys and endocrine glands in patients with arterial hypertension, discussing the methods with a view to obtainable information, limits of detection, and indications. (orig.).

  6. [Critical evaluation of current diagnostic classification systems in psychiatry: the case of DSM-5].

    Science.gov (United States)

    Luciano, Mario; Sampogna, Gaia; Del Vecchio, Valeria; De Rosa, Corrado; Albert, Umberto; Carrà, Giuseppe; Dell'Osso, Bernardo; Lorenzo, Giorgio Di; Ferrari, Silvia; Martinotti, Giovanni; Nanni, Maria Giulia; Pinna, Federica; Pompili, Maurizio; Volpe, Umberto; Catapano, Francesco; Fiorillo, Andrea

    2016-01-01

    Since its first edition, the Diagnostic and Statistical manual of Mental disorders (DSM) has had a great impact on the scientific community and the public opinion as well. In 2013, the American Psychiatric Association released the fifth edition of the manual and - as for the previous versions - several criticisms raised. In particular, the persistence of the categorical approach to mental disorders represents one of the main debated topics, as well as the introduction of new diagnostic syndromes, which are not based on an adequate evidences. Moreover, the threshold of diagnostic criteria for many mental disorders has been lowered, with the consequence that the boundaries between "normality" and "pathology" is not so clear. In this paper, we will: 1) report the historical development of the DSM from the publication of its first edition; 2) describe the main changes introduced in the DSM-5; 3) discuss critical elements in the DSM-5. The current debate regarding the validity of diagnostic manuals and its criteria is threatening the psychiatric discipline, but a possible solution should be represented by the integration of diagnostic criteria with the in-depth description of patient's psychopathological experiences.

  7. Advantages and disadvantages of current diagnostic tests for the detection of Helicobacter pylori.

    Science.gov (United States)

    Mégraud, F

    1996-01-01

    Current tests used to detect Helicobacter pylori are either invasive (histological detection, culture, the polymerase chain reaction (PCR), smear examination) or non-invasive (serology, 13C-urea breath test). These tests vary in their sensitivity and specificity, and the choice of test will depend on the situation, for example, whether the test is to detect infection or the success of eradication treatment. The accuracy of histological tests depends, to a large degree, on the expertise of the pathologist, while the accuracy of culture can depend on the conditions in which the specimen is transported and processed. When performed under optimal conditions, both techniques give very good results. The PCR test has similar sensitivity and specificity to histological and culture tests but a strict protocol must be followed to avoid contamination with H. pylori DNA. The rapid urease test (with a reading taken 1 hour later) is suitable for diagnosis before treatment but its sensitivity decreases after treatment. Smear examination has limited sensitivity. The urea breath test and serology (specific IgG detected by enzyme-linked immunosorbent assay with purified antigens) have sensitivities close to those using the best of the biopsy methods. Other points to consider when selecting a test are its availability, the rapidity of the results (which can range from a few minutes to 2 weeks), possibilities for retrospective analysis, quantification and the detection of pathogenic properties, the globality of certain tests that present an overall picture of the stomach, thus avoiding errors in sampling, and the cost of the test. Important added value can be gained from certain tests: histology allows evaluation of the status of the mucosa, culture allows strain typing and tests for antibiotic susceptibility, and the breath test can confirm successful eradication without endoscopy. When the diagnostic tests are performed correctly, most of them are highly accurate.

  8. Current means for plasma diagnostics and their application for materials and environment control. Materials of IV Russian seminar

    International Nuclear Information System (INIS)

    2003-01-01

    The collection contains reports made at the Fourth Russian seminar Current means of plasma diagnostics and their application for materials and environment control. The seminar took place in Moscow, November 12-14, 2003. The content of the collection covers both questions of plasma diagnostics in thermonuclear reactors and problems of diagnostics of pulsed and stationary gas discharges in research and technological installations. The reports on plasma diagnostics applied for some tasks of medicine and environment control are presented [ru

  9. A current view of the diagnostics and treatment of phenylketonuria in Slovakia

    Directory of Open Access Journals (Sweden)

    Ürge Oto

    2015-12-01

    Full Text Available An overview of the diagnostics and treatment of phenylketonuria in Slovakia is presented in this paper. The nature of diseases, incidence and prevalence in Slovakia, its genetic characteristics, current laboratory diagnostics and treatment options are defined. A new method of phenylketonuria screening in Slovakia, which has brought substantial improvement in early detection of the disease and shortening time for definitive diagnosis since 1995 as well as the importance of a tandem MS/MS (mass spectrometry introduced in the diagnosis of inherited metabolic disorders, is presented. The current state of phenylketonuria treatment focusing on low-protein dietary treatment and supplementation of amino acid mixtures is analysed. The use of sapropterin, enzyme replacement therapy, large neutral amino acids supplementation and gene therapy are also discussed.

  10. A Current Review of the Diagnostic and Treatment Strategies of Hepatic Encephalopathy

    Directory of Open Access Journals (Sweden)

    Z. Poh

    2012-01-01

    Full Text Available Hepatic encephalopathy (HE is a serious and potentially fatal complication in patients with cirrhotic liver disease. It is a spectrum ranging from minimal hepatic encephalopathy (MHE without recognizable clinical symptoms or signs, to overt HE with risk of cerebral edema and death. HE results in diminished quality of life and survival. The broad range of neuropsychiatric manifestations reflects the range of pathophysiological mechanisms and impairment in neurotransmission that are purported to cause HE including hyperammonemia, astrocyte swelling, intra-astrocytic glutamine, upregulation of 18-kDa translocator protein (TSPO (formerly known as peripheral benzodiazepine receptor or PBTR, and manganese. There is a myriad of diagnostic tools including simple bedside clinical assessment, and more complex neuropsychological batteries and neurophysiological tests available today. Current treatment strategies are directed at reducing ammonia, with newer agents showing some early promise. This paper describes the pathophysiology of the disease and summarises current diagnostic and treatment therapies available.

  11. Detection of localized damage by eddy currents technique

    Directory of Open Access Journals (Sweden)

    Aoukili A.

    2014-01-01

    Full Text Available Non destructive evaluation techniques based on eddy currents (EC are largely used for quality control of the castings in a lot of industries. The principle of detection by EC consists in using an adequate inductive coil to generate them by a variable magnetic field, and measuring their effects by using one or several sensors. These effects result from the interaction between the induced magnetic field and the excited conductive material. A local variation of the physical properties or geometry of the tested sample, due to a singularity or a flaw, causes a modification of the EC distribution, enabling thus detection. In order to optimize the capacity of defect revealing by means of EC based probes, an accurate modelling of the problem is essential. This can be used to perform simulation of the EC distribution under different circumstances and to analyze the EC sensitivity to the various implicated parameters. In this work, the modelling of EC is made by using the finite element method. Using a B-scan strategy was used, detection of a small defect having the shape of an open cavity is shown to be correctly indicated via monitoring variations of the induced voltage in the receiver coil.

  12. Detection of an anomalous pressure on a magneto-inertial-fusion load current diagnostic

    International Nuclear Information System (INIS)

    Hess, Mark Harry; Hutsel, Brian Thomas; Jennings, Christopher Ashley; VanDevender, J. Pace; Sefkow, Adam B.

    2017-01-01

    Recent Magnetized Liner Inertial Fusion experiments at the Sandia National Laboratories Z pulsed power facility have featured a PDV (Photonic Doppler Velocimetry) diagnostic in the final power feed section for measuring load current. In this paper, we report on an anomalous pressure that is detected on this PDV diagnostic very early in time during the current ramp. Early time load currents that are greater than both B-dot upstream current measurements and existing Z machine circuit models by at least 1 MA would be necessary to describe the measured early time velocity of the PDV flyer. This leads us to infer that the pressure producing the early time PDV flyer motion cannot be attributed to the magnetic pressure of the load current but rather to an anomalous pressure. Using the MHD code ALEGRA, we are able to compute a time-dependent anomalous pressure function, which when added to the magnetic pressure of the load current, yields simulated flyer velocities that are in excellent agreement with the PDV measurement. As a result, we also provide plausible explanations for what could be the origin of the anomalous pressure.

  13. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method

    International Nuclear Information System (INIS)

    Tang Qi; Song Zifeng; Chen Jiabin; Zhan Xiayu

    2013-01-01

    Ion temperature of implosion hotspot is a very important parameter for inertial confinement fusion. It reflects the energy level of the hotspot, and it is very sensitive to implosion symmetry and implosion speed. ICF implosion hotspot ion temperature diagnostic techniques based on neutron time-of-flight method were described. A neutron TOF spectrometer was developed using a ultrafast plastic scintillator as the neutron detector. Time response of the spectrometer has 1.1 ns FWHM and 0.5 ns rising time. TOF spectrum resolving method based on deconvolution and low pass filter was illuminated. Implosion hotspot ion temperature in low neutron yield and low ion temperature condition at Shenguang-Ⅲ facility was acquired using the diagnostic techniques. (authors)

  14. The Diagnostic Challenge Competition: Probabilistic Techniques for Fault Diagnosis in Electrical Power Systems

    Science.gov (United States)

    Ricks, Brian W.; Mengshoel, Ole J.

    2009-01-01

    Reliable systems health management is an important research area of NASA. A health management system that can accurately and quickly diagnose faults in various on-board systems of a vehicle will play a key role in the success of current and future NASA missions. We introduce in this paper the ProDiagnose algorithm, a diagnostic algorithm that uses a probabilistic approach, accomplished with Bayesian Network models compiled to Arithmetic Circuits, to diagnose these systems. We describe the ProDiagnose algorithm, how it works, and the probabilistic models involved. We show by experimentation on two Electrical Power Systems based on the ADAPT testbed, used in the Diagnostic Challenge Competition (DX 09), that ProDiagnose can produce results with over 96% accuracy and less than 1 second mean diagnostic time.

  15. MR cholangiopancreatography: prospective comparison of a breath-hold 2D projection technique with diagnostic ERCP

    International Nuclear Information System (INIS)

    Lomas, D.J.; Bearcroft, P.W.P.; Gimson, A.E.

    1999-01-01

    The aim of this study was to compare prospectively a breath-hold projection magnetic resonance cholangiopancreatography (MRCP) technique with diagnostic endoscopic retrograde cholangiopancreatography (ERCP). Seventy-six patients with suspected strictures or choledocholithiasis were referred for MRCP and subsequent ERCP examination, which were performed within 4 h of each other. The MRCP technique was performed using fat-suppressed rapid acquisition with relaxation enhancement (RARE) projection images obtained in standardised planes with additional targeted projections as required by the supervising radiologist. Two radiologists (in consensus) assessed the MRCP results prospectively and independently for the presence of bile duct calculi, strictures, non-specific biliary dilatation and pancreatic duct dilatation, and recorded a single primary diagnosis. The ERCP was assessed prospectively and independently by a single endoscopist and used as a gold standard for comparison with MRCP. Diagnostic agreement was assessed by the Kappa statistic. The MRCP technique failed in two patients and ERCP in five. In the remaining 69 referrals ERCP demonstrated normal findings in 23 cases, strictures in 19 cases, choledocholithiasis in 9 cases, non-specific biliary dilatation in 14 cases and chronic pancreatitis in 4 cases. The MRCP technique correctly demonstrated 22 of 23 normal cases, 19 strictures with one false positive (sensitivity 100 %, specificity 98 %), all 9 cases of choledocholithiasis with two false positives (sensitivity 100 %, specificity 97 %), 12 of 14 cases of non-specific biliary dilatation and only 1 of 4 cases of chronic pancreatitis. There was overall good agreement for diagnosis based on a kappa value of 0.88. Breath-hold projection MRCP can provide non-invasively comparable diagnostic information to diagnostic ERCP for suspected choledocholithiasis and biliary strictures and may allow more selective use of therapeutic ERCP. (orig.)

  16. Plasma diagnostic techniques in thermal-barrier tandem-mirror fusion experiments

    International Nuclear Information System (INIS)

    Silver, E.H.; Clauser, J.F.; Carter, M.R.; Failor, B.H.; Foote, J.H.; Hornady, R.S.; James, R.A.; Lasnier, C.J.; Perkins, D.E.

    1986-01-01

    We review two classes of plasma diagnostic techniques used in thermal-barrier tandem-mirror fusion experiments. The emphasis of the first class is to study mirror-trapped electrons at the thermal-barrier location. The focus of the second class is to measure the spatial and temporal behavior of the plasma space potential at various axial locations. The design and operation of the instruments in these two categories are discussed and data that are representative of their performance is presented

  17. The evaluation of the irradiation of medical team in critical X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    A good realized assessment of the irradiation for any exposed group of population serves as the base for the radiation protection measures (emergency radiation preparedness, radiation protection optimization etc.). This is especially important, by the radiation protection point of view, in contrast X-ray diagnostic techniques - angiographies. This paper presents the way for the realization of the medical team irradiation assessment, based on originally derived simple equations for the scattered radiation field around patient. (author) 1 fig., 3 figs.

  18. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    International Nuclear Information System (INIS)

    Kuznetsov, Yu L; Kalchenko, V V; Astaf'eva, N G; Meglinski, I V

    2014-01-01

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  19. Optical diagnostics of vascular reactions triggered by weak allergens using laser speckle-contrast imaging technique

    Energy Technology Data Exchange (ETDEWEB)

    Kuznetsov, Yu L; Kalchenko, V V [Department of Veterinary Resources, Weizmann Institute of Science, Rehovot, 76100 (Israel); Astaf' eva, N G [V.I.Razumovsky Saratov State Medical University, Saratov (Russian Federation); Meglinski, I V [N.G. Chernyshevsky Saratov State University, Saratov (Russian Federation)

    2014-08-31

    The capability of using the laser speckle contrast imaging technique with a long exposure time for visualisation of primary acute skin vascular reactions caused by a topical application of a weak contact allergen is considered. The method is shown to provide efficient and accurate detection of irritant-induced primary acute vascular reactions of skin. The presented technique possesses a high potential in everyday diagnostic practice, preclinical studies, as well as in the prognosis of skin reactions to the interaction with potentially allergenic materials. (laser biophotonics)

  20. The Anomalous Currents In The Front Foils of the JET Lost Alpha Diagnostic KA-2

    International Nuclear Information System (INIS)

    Cecil, F.E.; Kiptily, V.; Salmi, A.; Horton, A.; Fullard, K.; Murari, A.; Darrow, D.; Hill, K.

    2011-01-01

    We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions (both deuterium and impurity) in the vicinity of the detector (including charge exchange neutrals) and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

  1. The Anomalous Currents In The Front Foils of the JET Lost Alpha Diagnostic KA-2

    Energy Technology Data Exchange (ETDEWEB)

    Cecil, F. E.; Kiptily, V.; Salmi, A.; Horton, A.; Fullard, K.; Murari, A.; Darrow, D.; Hill, K.

    2011-05-04

    We have examined the observed currents in the front foils of the JET Faraday cup lost alpha particle diagnostic KA-2. In particular, we have sought to understand the currents during Ohmic plasmas for which the ion flux at the detectors was initially assumed to be negligible. We have considered two sources of this current: plasma ions both deuterium and impurity in the vicinity of the detector including charge exchange neutrals and photoemission from scattered UV radiation. Based upon modeling and empirical observation, the latter source appears most likely and, moreover, seems to be applicable to the currents in the front foil during ELMy H-mode plasmas. A very thin gold or nickel foil attached to the present detector aperture is proposed as a solution to this problem, and realistic calculations of expected fluxes of lost energetic neutral beam ions during TF ripple experiments are presented as justification of this proposed solution.

  2. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    Energy Technology Data Exchange (ETDEWEB)

    Shah, Chirag [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States); Vicini, Frank A., E-mail: fvicini@beaumont.edu [Department of Radiation Oncology, William Beaumont Hospital, Royal Oak, MI (United States)

    2011-11-15

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer-related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2-65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  3. Breast Cancer-Related Arm Lymphedema: Incidence Rates, Diagnostic Techniques, Optimal Management and Risk Reduction Strategies

    International Nuclear Information System (INIS)

    Shah, Chirag; Vicini, Frank A.

    2011-01-01

    As more women survive breast cancer, long-term toxicities affecting their quality of life, such as lymphedema (LE) of the arm, gain importance. Although numerous studies have attempted to determine incidence rates, identify optimal diagnostic tests, enumerate efficacious treatment strategies and outline risk reduction guidelines for breast cancer–related lymphedema (BCRL), few groups have consistently agreed on any of these issues. As a result, standardized recommendations are still lacking. This review will summarize the latest data addressing all of these concerns in order to provide patients and health care providers with optimal, contemporary recommendations. Published incidence rates for BCRL vary substantially with a range of 2–65% based on surgical technique, axillary sampling method, radiation therapy fields treated, and the use of chemotherapy. Newer clinical assessment tools can potentially identify BCRL in patients with subclinical disease with prospective data suggesting that early diagnosis and management with noninvasive therapy can lead to excellent outcomes. Multiple therapies exist with treatments defined by the severity of BCRL present. Currently, the standard of care for BCRL in patients with significant LE is complex decongestive physiotherapy (CDP). Contemporary data also suggest that a multidisciplinary approach to the management of BCRL should begin prior to definitive treatment for breast cancer employing patient-specific surgical, radiation therapy, and chemotherapy paradigms that limit risks. Further, prospective clinical assessments before and after treatment should be employed to diagnose subclinical disease. In those patients who require aggressive locoregional management, prophylactic therapies and the use of CDP can help reduce the long-term sequelae of BCRL.

  4. Optimized design of shields for diagnostic X rays with NCRP 147 technique

    International Nuclear Information System (INIS)

    Gama T, G.

    2006-01-01

    A comparison among the design techniques of shielding for X-ray diagnostic rooms with the NCRP 49 (1976) report technique, AAPM 39 (1993) Y the one of the NCRP 147 (2005) technique. The designs correspond to a room of conventional X-rays, one of fluoroscopy, one of tomography Y one of mammography. In all the cases it demonstrates that the NCRP 49 technique overestimate the shieldings. The causes of the overestimation of the NCRP 49 can be attributed to: a) high values of the work charge that don't consider the spectral fluence of the photons that are present in each room, b) to the differences in the values of the kerma in air without attenuation for the dispersed primary radiation Y of leakage among both reports. (Author)

  5. Clinicians' perspective of the current diagnostic criteria for myofascial pain syndrome.

    Science.gov (United States)

    Grosman-Rimon, Liza; Clarke, Hance; Chan, Aaron K; Mills, Patricia Branco; Rathbone, Alasdair Timothy Llewelyn; Kumbhare, Dinesh

    2017-01-01

    Myofascial pain syndrome (MPS) is one of the most common chronic musculoskeletal pain disorders. However, MPS is often under-diagnosed. The purpose of this study was to characterize practicing clinicians' perspectives of the current diagnostic criteria for MPS. A cross-sectional study design was used with a self-administered questionnaire. The questionnaire evaluated clinicians' perspective of the current diagnostic criteria for MPS. The sample population (n= 119) consisted of 40% family physicians, 31% physical medicine (PM) and rehabilitation specialists, 11% rheumatologists, 10% emergency room (ER) physicians, and 8% anesthesiologists specializing in chronic pain. Our findings demonstrated that participating clinicians agree that ``point tenderness'' and ``pain reproduction'' are criteria for MPS. In contrast, the clinicians do not consider ``autonomic symptoms'' as an important criterion for MPS. The anesthesiologists view ``restricted range of motion'' as a criterion for MPS more than the other groups, and they tend to consider ``referred pain'' and ``pain reproduction'' as criteria. Physical medicine and rehabilitation specialists and anesthesiologists tend to view ``local twitch response'' more as a criterion for MPS compared with the other groups. Most groups of clinicians consider ``weakness without atrophy'' as an important MPS criterion except for family physicians. It is important to note that ``poor sleep'', ``daytime fatigue'' and ``cognitive symptoms'', which are not considered as MPS symptoms, are often mistaken for MPS among practicing clinicians. Our findings suggest that the diagnostic criteria are not well known, highlighting the need for an expert consensus to determine the importance of each criterion for MPS diagnosis.

  6. A review of mild traumatic brain injury diagnostics: current perspectives, limitations, and emerging technology.

    Science.gov (United States)

    Cook, Glen A; Hawley, Jason S

    2014-10-01

    Mild traumatic brain injury (mTBI) or concussion is a common battlefield and in-garrison injury caused by transmission of mechanical forces to the head. The energy transferred in such events can cause structural and/or functional changes in the brain that manifest as focal neurological, cognitive, or behavioral dysfunction. Current diagnostic criteria for mTBI are highly limited, variable, and based on subjective self-report. The subjective nature of the symptoms, both in quantity and quality, together with their large overlap in other physical and behavioral maladies, limit the clinician's ability to accurately diagnose, treat, and make prognostic decisions after such injuries. These diagnostic challenges are magnified in an operational environment as well. The Department of Defense has invested significant resources into improving the diagnostic tools and accuracy for mTBI. This focus has been to supplement the clinician's examination with technology that is better able to objectify brain dysfunction after mTBI. Through this review, we discuss the current state of three promising technologies--soluble protein biomarkers, advanced neuroimaging, and quantitative electroencephalography--that are of particular interest within military medicine. Reprint & Copyright © 2014 Association of Military Surgeons of the U.S.

  7. Respiratory gated radiotherapy: current techniques and potential benefits

    International Nuclear Information System (INIS)

    Giraud, P.; Campana, F.; Rosenwald, J.C.; Cosset, J.M.; Reboul, F.; Garcia, R.; Clippe, S.; Carrie, C.; Dubray, B.

    2003-01-01

    Respiration-gated radiotherapy offers a significant potential for improvement in the irradiation of tumor sites affected by respiratory motion such as lung, breast and liver tumors. An increased conformality of irradiation fields leading to decreased complications rates of organs at risk (lung, heart...) is expected. Respiratory gating is in line with the need for improved precision required by radiotherapy techniques such as 3D conformal radiotherapy or intensity modulated radiotherapy. Reduction of respiratory motion can be achieved by using either breath hold techniques or respiration synchronized gating techniques. Breath-hold techniques can be achieved with active, in which airflow of the patient is temporarily blocked by a valve, or passive techniques, in which the patient voluntarily breath-hold. Synchronized gating techniques use external devices to predict the phase of the respiration cycle while the patient breaths freely. These techniques presently investigated in several medical centers worldwide. Although promising, the first results obtained in lung and liver cancer patients require confirmation. Physical, technical and physiological questions still remain to be answered. This paper describes the most frequently used gated techniques and the main published clinical reports on the use of respiration-gated radiotherapy in order to evaluate the impact of these techniques. (author)

  8. Petroleum Pumps’ Current and Vibration Signatures Analysis Using Wavelet Coherence Technique

    Directory of Open Access Journals (Sweden)

    Rmdan Shnibha

    2013-01-01

    Full Text Available Vibration analysis is widely used for rotating machinery diagnostics; however measuring vibration of operational oil well pumps is not possible. The pump’s driver’s current signatures may provide condition-related information without the need for an access to the pump itself. This paper investigates the degree of relationship between the pump’s driver’s current signatures and its induced vibration. This relationship between the driver’s current signatures (DCS and its vibration signatures (DVS is studied by calculating magnitude-squared coherence and phase coherence parameters at a certain frequency band using continuous wavelet transform (CWT. The CWT coherence-based technique allows better analysis of temporal evolution of the frequency content of dynamic signals and areas in the time-frequency plane where the two signals exhibit common power or consistent phase behaviour indicating a relationship between the signals. This novel approach is validated by experimental data acquired from 3 kW petroleum pump’s driver. Both vibration and current signatures were acquired under different speed and load conditions. The outcomes of this research suggest the use of DCS analysis as reliable and inexpensive condition monitoring tool, which could be implemented for oil pumps, real-time monitoring associated with condition-based maintenance (CBM program.

  9. Comparison radiation dose of Z-axis automatic tube current modulation technique with fixed tube current multi-detector row CT scanning of lower extremity venography

    International Nuclear Information System (INIS)

    Yoo, Beong Gyu; Kweon, Dae Cheol; Lee, Jong Seok; Jang, Keun Jo; Jeon, Sang Hwan; Kim, Yong Soo

    2007-01-01

    Z-axis automatic tube current modulation technique automatically adjusts tube current based on size of body region scanned. The purpose of the current study was to compare noise, and radiation dose of Multi-Detector row CT (MDCT) of lower extremity performed with Z-axis modulation technique of automatic tube current modulation with manual selection fixed tube current. Fifty consecutive underwent MDCT venography of lower extremity with use of a MDCT scanner fixed tube current and Z-axis automatic tube current modulation technique (10, 11 and 12 HU noise index, 70∼450 mA). Scanning parameters included 120 kVp, 0.5 second gantry rotation time, 1.35:1 beam pitch, and 1 mm reconstructed section thickness. For each subject, images obtained with Z-axis modulation were compared with previous images obtained with fixed tube current (200, 250, 300 mA) and with other parameters identical. Images were compared for noise at five levels: iliac, femoral, popliteal, tibial, and peroneal vein of lower extremity. Tube current and gantry rotation time used for acquisitions at these levels were recorded. All CT examinations of study and control groups were diagnostically acceptable, though objective noise was significantly more with Z-axis automatic tube current modulation. Compared with fixed tube current, Z-axis modulation resulted in reduction of CTDIvol (range, -6.5%∼-35.6%) and DLP (range,-0.2%∼-20.2%). Compared with manually selected fixed tube current, Z-axis automatic tube current modulation resulted in reduced radiation dose at MDCT of lower extremity venography

  10. Important hemoprotozoan diseases of livestock: Challenges in current diagnostics and therapeutics: An update

    Directory of Open Access Journals (Sweden)

    Biswa Ranjan Maharana

    2016-05-01

    Full Text Available Hemoprotozoan parasites pose a serious threat to the livestock population in terms of mortality, reduced milk yield and lowered draft power. Diagnosis of these diseases often poses a challenging task. Needless to say that impact of disease in health and productivity is huge though a fair economic assessment on the quantum of economic loss associated is yet to be worked out from India. The diagnosis of hemoprotozoan infections largely depends on various laboratory-based diagnostic methods as the clinical manifestations are often inconspicuous and non-specific. Traditional diagnostic methods rely on microscopical demonstration of infective stages in blood or tissue fluids. However, it is laborious, lesser sensitive, and cannot differentiate between morphologically similar organisms. Recent development in the technologies has opened new avenues for improvement in the accurate diagnosis of parasitic infections. Serological tests are simple, fast but lack specificity. With advent of molecular techniques, as DNA hybridization assays, polymerase chain reaction and its modifications ensure the detection of infection in the latent phase of the disease. Nucleic acid-based assays are highly sensitive, free from immunocompetence and can differentiate between morphologically similar parasites. With the advent of newer diagnostics complemented with traditional ones will be of huge help for targeted selective treatment with better chemotherapeutic agents.

  11. Vibration monitoring/diagnostic techniques, as applied to reactor coolant pumps

    International Nuclear Information System (INIS)

    Sculthorpe, B.R.; Johnson, K.M.

    1986-01-01

    With the increased awareness of reactor coolant pump (RCP) cracked shafts, brought about by the catastrophic shaft failure at Crystal River number3, Florida Power and Light Company, in conjunction with Bently Nevada Corporation, undertook a test program at St. Lucie Nuclear Unit number2, to confirm the integrity of all four RCP pump shafts. Reactor coolant pumps play a major roll in the operation of nuclear-powered generation facilities. The time required to disassemble and physically inspect a single RCP shaft would be lengthy, monetarily costly to the utility and its customers, and cause possible unnecessary man-rem exposure to plant personnel. When properly applied, vibration instrumentation can increase unit availability/reliability, as well as provide enhanced diagnostic capability. This paper reviews monitoring benefits and diagnostic techniques applicable to RCPs/motor drives

  12. Improvement of diagnostic techniques and electrical circuit in azo dye degradation by high voltage electrical discharge

    International Nuclear Information System (INIS)

    Shen Yongjun; Lei Lecheng; Zhang Xingwang; Zhou Minghua; Zhang Yi

    2008-01-01

    Fast electrical diagnostics and improvement of electrical circuits for methyl orange (MO) degradation by high voltage pulsed electrical discharge were investigated. To eliminate electromagnetic radiation, several effective methods were employed. RG 218 coaxial cable was substituted for the common transmission lines to transmit high voltage pulses, and multi-lines in parallel were earthed to avoid electromagnetic interference and, additionally, to reduce the stray inductance of the electrical circuit and increase the pulse rise rate to reduce the energy losses in the transmission system. The problem of the differences in the bandwidths of voltage and current probes causing an error in the calculation of energy dissipation was avoided by reducing the bandwidths of voltage and current measurements to the same value. The real discharge current was obtained by subtracting the capacitive current from the total current. The energy per pulse obtained in the reactor before and after improvement of the diagnostics and electrical circuit were 15.5 mJ and 26.8 mJ, respectively, and the energy efficiencies of MO degradation were 1.34 x 10 -9 mol/J and 1.95 x 10 -9 mol/J, respectively

  13. Atypical Alstrom syndrome with novel ALMS1 mutations precluded by current diagnostic criteria.

    LENUS (Irish Health Repository)

    Casey, Jillian

    2014-02-01

    We report on clinical and genetic studies in a non-consanguineous Irish sib-pair with infantile dilated cardiomyopathy and retinopathy. A diagnosis of Alström Syndrome (AS) was considered and diagnostic testing pursued. The Alströms gene (ALMS1) is very large (23 exons) and diagnostic testing of mutational hotspots (exon 6, 8 and 10) was negative. Furthermore the siblings were tall and did not have the typical phenotype of nystagmus, photophobia, obesity or hearing loss and so the AS diagnosis was removed. We then sought to identify the causative gene in this family using whole exome sequencing. Unexpectedly, the exome analysis identified novel compound heterozygous ALMS1 mutations in exon 5 (c.777delT:p.D260fs*26) and exon 20 (c.12145_12146insC:p.S4049fs*36) that segregated with the phenotype. Although the siblings show some clinical overlap with AS, their phenotype is not classical. It is plausible that their atypical presentation may be due to the location of the ALMS1 mutations outside the usual mutational hotspots. Our findings show how atypical cases of AS may be missed under the current diagnostic guidelines and support consideration of complete ALMS1 sequencing in children with two or more features, even if all of the core clinical features of AS are not present.

  14. PREFACE: IX International Conference on Modern Techniques of Plasma Diagnostics and their Application

    Science.gov (United States)

    Savjolov, A. S.; Dodulad, E. I.

    2016-01-01

    The IX Conference on ''Modern Techniques of Plasma Diagnosis and their Application'' was held on 5 - 7 November, 2014 at National Research Nuclear University MEPhI (NRNU MEPhI). The goal of the conference was an exchange of information on both high-temperature and low-temperature plasma diagnostics as well as deliberation and analysis of various diagnostic techniques and their applicability in science, industry, ecology, medicine and other fields. The Conference also provided young scientists from scientific centres and universities engaged in plasma diagnostics with an opportunity to attend the lectures given by the leading specialists in this field as well as present their own results and findings. The first workshop titled ''Modern problems of plasma diagnostics and their application for control of chemicals and the environment'' took place at Moscow Engineering and Physics Institute (MEPhI) in June 1998 with the support of the Section on Diagnostics of the Council of Russian Academic of Science on Plasma Physics and since then these forums have been held at MEPhI every two years. In 2008 the workshop was assigned a conference status. More than 150 specialists on plasma diagnostics and students took part in the last conference. They represented leading Russian scientific centres (such as Troitsk Institute of Innovative and Thermonuclear Research, National Research Centre ''Kurchatov Institute'', Russian Federal Nuclear Centre - All-Russian Scientific Research Institute of Experimental Physics and others) and universities from Belarus, Ukraine, Germany, USA, Belgium and Sweden. About 30 reports were made by young researchers, students and post-graduate students. All presentations during the conference were broadcasted online over the internet with viewers in Moscow, Prague, St. Petersburgh and other cities. The Conference was held within the framework of the Centre of Plasma, Laser Research and Technology supported by MEPhI Academic Excellence Project (Russian

  15. Evidence-based medical research on diagnostic criteria and screening technique of vascular mild cognitive impairment

    Directory of Open Access Journals (Sweden)

    Xia-wei LIU

    2015-07-01

    Full Text Available Background Vascular mild cognitive impairment (VaMCI is the prodromal syndrome of vascular dementia (VaD and key target for drug treatment. There is controversy over the diagnostic criteria and screening tools of VaMCI, which affects its clinical diagnosis. This paper aims to explore the clinical features, diagnostic criteria and screening technique of VaMCI.  Methods Taking "vascular mild cognitive impairment OR vascular cognitive impairment no dementia" as retrieval terms, search in PubMed database from January 1997 to March 2015 and screen relevant literatures concerning VaMCI. According to Guidance for the Preparation of Neurological Management Guidelines revised by European Federation of Neurological Societies (EFNS in 2004, evidence grading was performed on literatures. Results A total of 32 literatures in English were selected according to inclusion and exclusion criteria, including 3 guidelines and consensus and 29 clinical studies. Seven literatures (2 on Level Ⅰ, 5 on Level Ⅱ studied on neuropsychological features in VaMCI patients and found reduced processing speed and executive function impairment were main features. Two literatures reported the diagnostic criteria of VaMCI, including VaMCI criteria published by American Heart Association (AHA/American Stroke Association (ASA in 2011 and "Diagnostic Criteria for Vascular Cognitive Disorders" published by International Society for Vascular Behavioral and Cognitive Disorders (VASCOG in 2014. Fifteen literatures (4 on LevelⅠ, 11 on Level Ⅱ described the diagnostic criteria of VaMCI used in clinical research, from which 6 operational diagnostic items were extracted. Fourteen literatures (4 on Level Ⅰ, 10 on Level Ⅱ described neuropsychological assessment tools for VaMCI screening, and found the 5-minute protocol recommended by National Institute of Neurological Disorders and Stroke-Canadian Stroke Network (NINDS-CSN was being good consistency with other neuropsychological

  16. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2013-09-15

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  17. Advanced Surveillance, Diagnostic and Prognostic Techniques in Monitoring Structures, Systems and Components in Nuclear Power Plants

    International Nuclear Information System (INIS)

    2013-01-01

    direction of research, development and demonstration in this area. The technologies discussed in this project are intended to establish the state of the art in surveillance, diagnostics and prognostics (SDP) technologies for equipment and process health monitoring in nuclear facilities. It is also intended to identify technology gaps and research needs of the nuclear industry in the area of SDP. The report draws on the conventional SDP technologies, as well as the latest tools, algorithms and techniques that have emerged over the last few years, especially in enabling technologies including fast data acquisition, data storage, data qualification and data analysis algorithms, such as empirical and physical modelling techniques. These new tools have made it possible to identify problems earlier and with better resolution. The significance of the material presented in this report is that it contributes not only to the current needs of the nuclear industry but also to the design improvements of the next generation of reactors. For example, the nuclear industry is currently striving to operate the plants for up to 80 years or more, as the value of nuclear assets has risen in recent years, resulting partly from environmental concerns with fossil energy production, as well as increased future demand for base load electricity. This long term operation (LTO) or life extension goal of the nuclear industry has stimulated renewed interest in more frequent monitoring of equipment to guard against ageing effects, not to mention the economic benefits that SDP implementation can produce, and contributions to radiation exposure that is as low as reasonably achievable, reduction of human errors, and optimized maintenance. Together with capabilities that enhance situational awareness, the technologies described in this report will enable more holistic management of plant structures, systems and components (SSCs), maintain high capacity factor in LTO and enable higher levels of safe operation

  18. Imaging techniques used in the diagnostic workup of acute venous thromboembolic disease.

    Science.gov (United States)

    Tilve-Gómez, A; Rodríguez-Fernández, P; Trillo-Fandiño, L; Plasencia-Martínez, J M

    Early diagnosis is one of the most important factors affecting the prognosis of pulmonary embolism (PE); however, the clinical presentation of PE is often very unspecific and it can simulate other diseases. For these reasons, imaging tests, especially computed tomography angiography (CTA) of the pulmonary arteries, have become the keystone in the diagnostic workup of PE. The wide availability and high diagnostic performance of pulmonary CTA has led to an increase in the number of examinations done and a consequent increase in the population's exposure to radiation and iodinated contrast material. Thus, other techniques such as scintigraphy and venous ultrasonography of the lower limbs, although less accurate, continue to be used in certain circumstances, and optimized protocols have been developed for CTA to reduce the dose of radiation (by decreasing the kilovoltage) and the dose of contrast agents. We describe the technical characteristics and interpretation of the findings for each imaging technique used to diagnose PE and discuss their advantages and limitations; this knowledge will help the best technique to be chosen for each case. Finally, we comment on some data about the increased use of CTA, its clinical repercussions, its "overuse", and doubts about its cost-effectiveness. Copyright © 2016 SERAM. Publicado por Elsevier España, S.L.U. All rights reserved.

  19. Fundamentals of functional imaging I: current clinical techniques.

    Science.gov (United States)

    Luna, A; Martín Noguerol, T; Mata, L Alcalá

    2018-05-01

    Imaging techniques can establish a structural, physiological, and molecular phenotype for cancer, which helps enable accurate diagnosis and personalized treatment. In recent years, various imaging techniques that make it possible to study the functional characteristics of tumors quantitatively and reproducibly have been introduced and have become established in routine clinical practice. Perfusion studies enable us to estimate the microcirculation as well as tumor angiogenesis and permeability using ultrafast dynamic acquisitions with ultrasound, computed tomography, or magnetic resonance (MR) imaging. Diffusion-weighted sequences now form part of state-of-the-art MR imaging protocols to evaluate oncologic lesions in any anatomic location. Diffusion-weighted imaging provides information about the occupation of the extracellular and extravascular space and indirectly estimates the cellularity and apoptosis of tumors, having demonstrated its relation with biologic aggressiveness in various tumor lines and its usefulness in the evaluation of the early response to systemic and local targeted therapies. Another tool is hydrogen proton MR spectroscopy, which is used mainly in the study of the metabolic characteristics of brain tumors. However, the complexity of the technique and its lack of reproducibility have limited its clinical use in other anatomic areas, although much experience with the use of this technique in the assessment of prostate and breast cancers as well as liver lesions has also accumulated. This review analyzes the imaging techniques that make it possible to evaluate the physiological and molecular characteristics of cancer that have already been introduced into clinical practice, such as techniques that evaluate angiogenesis through dynamic acquisitions after the administration of contrast material, diffusion-weighted imaging, or hydrogen proton MR spectroscopy, as well as their principal applications in oncology. Copyright © 2018 SERAM. Publicado

  20. Current trends in nuclear borehole logging techniques for elemental analysis

    International Nuclear Information System (INIS)

    1988-06-01

    This report is the result of a consultants' meeting organized by the IAEA and held in Ottawa, Canada, 2-6 November 1987 in order to assess the present technical status of nuclear borehole logging techniques, to find out the well established applications and the development trends. It contains a summary report giving a comprehensive overview of the techniques and applications and a collection of research papers describing work done in industrial institutes. A separate abstract was prepared for each of these 9 papers. Refs, figs and tabs

  1. THE TECHNIQUE OF DIAGNOSTICS OF THE PRODUCTION CAPACITY OF THE ORGANIZATION

    Directory of Open Access Journals (Sweden)

    E. S. Popova

    2014-01-01

    Full Text Available In the article due to the need for diagnostics of the production capacity of the organization. Formed methodological framework for evaluating the production potential of the organization. Research capacity will also enable the organization to timely respond to current changes. A classification of types of diagnostics of the production capacity of the organization according to the following criteria: timing, goals, content, purpose results. The article discusses the economic and organizational diagnosis of the production capacity of the organization. Economic diagnosis is based on the calculation of indicators of use of resources of the organization. Organizational diagnosis assesses the security of the organization's activities. Diagnosis productive capacity is the basis for improvement of the organization's activities. Defined diagnostics of the production capacity of the organization. Justified the selection stages of the research production potential. The first stage is the preliminary diagnosis. The second stage provides for the rapid diagnosis of production potential. At the third stage it is advisable to perform problem diagnosis. Problem diagnosis consists of economic and organizational diagnosis. Economic diagnosis assesses the state of the elements of the production potential of the organization. Organizational diagnostics analyses provide productive capacity. The fourth stage is represented by the solution of the problems of utilization of production capacity. Each stage is considered, has its content and specific diagnostic methods of production potential. This method allows determining the state of the elements, the efficiency of utilization of production capacity. The estimation of the production potential is based on the application of utility theory. This assessment provides a definition of the criteria and the scale of usefulness. This will allow you to measure the production potential numerically. In the end, it is revealed

  2. First principle leakage current reduction technique for CMOS devices

    CSIR Research Space (South Africa)

    Tsague, HD

    2015-12-01

    Full Text Available This paper presents a comprehensive study of leakage reduction techniques applicable to CMOS based devices. In the process, mathematical equations that model the power-performance trade-offs in CMOS logic circuits are presented. From those equations...

  3. Molecular techniques for MRSA typing: current issues and perspectives

    Directory of Open Access Journals (Sweden)

    P. A. Trindade

    Full Text Available Staphylococcus aureus has long been recognised as an important pathogen in human disease. Serious staphylococcal infections can frequently occur in inpatients and may lead to dire consequences, especially as to therapy with antimicrobial agents. The increase in the frequency of Methicillin-Resistant Staphylococcus aureus (MRSA as the causal agent of nosocomial infection and the possibility of emergence of resistance to vancomycin demands a quick and trustworthy characterization of isolates and identification of clonal spread within hospitals. Enough information must be generated to permit the implementation of appropriate measures for control of infection, so that outbreaks can be contained. Molecular typing techniques reviewed in this manuscript include: plasmid profile analysis, analysis of chromosomal DNA after enzymatic restriction, Southern blotting, pulsed field gel electrophoresis (PFGE, techniques involving polymerase chain reaction and multilocus sequence typing (MLST. Repetitive DNA Sequence PCR (rep-PCR may be used for screening due to its practicality, low cost and reproducibility. Because of its high discriminatory power Pulsed-Field Gel Electrophoresis (PFGE still remains the gold standard for MRSA typing. New techniques with higher reproducibility and discriminatory power, such as Multi-Locus Sequence Typing (MLST, are appearing. These are mostly useful for global epidemiology studies. Molecular typing techniques are invaluable tools for the assessment of putative MRSA outbreaks and so should be extensively used for this purpose.

  4. Molecular techniques for MRSA typing: current issues and perspectives

    Directory of Open Access Journals (Sweden)

    Trindade P. A.

    2003-01-01

    Full Text Available Staphylococcus aureus has long been recognised as an important pathogen in human disease. Serious staphylococcal infections can frequently occur in inpatients and may lead to dire consequences, especially as to therapy with antimicrobial agents. The increase in the frequency of Methicillin-Resistant Staphylococcus aureus (MRSA as the causal agent of nosocomial infection and the possibility of emergence of resistance to vancomycin demands a quick and trustworthy characterization of isolates and identification of clonal spread within hospitals. Enough information must be generated to permit the implementation of appropriate measures for control of infection, so that outbreaks can be contained. Molecular typing techniques reviewed in this manuscript include: plasmid profile analysis, analysis of chromosomal DNA after enzymatic restriction, Southern blotting, pulsed field gel electrophoresis (PFGE, techniques involving polymerase chain reaction and multilocus sequence typing (MLST. Repetitive DNA Sequence PCR (rep-PCR may be used for screening due to its practicality, low cost and reproducibility. Because of its high discriminatory power Pulsed-Field Gel Electrophoresis (PFGE still remains the gold standard for MRSA typing. New techniques with higher reproducibility and discriminatory power, such as Multi-Locus Sequence Typing (MLST, are appearing. These are mostly useful for global epidemiology studies. Molecular typing techniques are invaluable tools for the assessment of putative MRSA outbreaks and so should be extensively used for this purpose.

  5. Picosecond high power laser systems and picosecond diagnostic technique in laser produced plasma

    International Nuclear Information System (INIS)

    Kuroda, Hiroto; Masuko, H.; Maekawa, Shigeru; Suzuki, Yoshiji; Sugiyama, Masaru.

    1979-01-01

    Highly repetitive, high power YAG and Glass laser systems have been developed and been successfully used for the studies of laser-plasma interactions. Various picosecond diagnostic techniques have been developed for such purposes in the regions from optical to X-ray frequency. Recently highly sensitive X-ray (1 - 10 KeV) streak camera for highly repetitive operations have been developed. Preliminary experiment shows the achievement of 28ps temporal resolution (100μm slit) and good sensitivity with detectable minimum number of 10E3-1KeV photons/shot/slit area. (author)

  6. Current and future molecular diagnostics in colorectal cancer and colorectal adenoma.

    Science.gov (United States)

    Tsang, Andy Hin-Fung; Cheng, Ka-Ho; Wong, Apple Siu-Ping; Ng, Simon Siu-Man; Ma, Brigette Buig-Yue; Chan, Charles Ming-Lok; Tsui, Nancy Bo-Yin; Chan, Lawrence Wing-Chi; Yung, Benjamin Yat-Ming; Wong, Sze-Chuen Cesar

    2014-04-14

    Colorectal cancer (CRC) is one of the most prevalent cancers in developed countries. On the other hand, CRC is also one of the most curable cancers if it is detected in early stages through regular colonoscopy or sigmoidoscopy. Since CRC develops slowly from precancerous lesions, early detection can reduce both the incidence and mortality of the disease. Fecal occult blood test is a widely used non-invasive screening tool for CRC. Although fecal occult blood test is simple and cost-effective in screening CRC, there is room for improvement in terms of the accuracy of the test. Genetic dysregulations have been found to play an important role in CRC development. With better understanding of the molecular basis of CRC, there is a growing expectation on the development of diagnostic tests based on more sensitive and specific molecular markers and those tests may provide a breakthrough to the limitations of current screening tests for CRC. In this review, the molecular basis of CRC development, the characteristics and applications of different non-invasive molecular biomarkers, as well as the technologies available for the detection were discussed. This review intended to provide a summary on the current and future molecular diagnostics in CRC and its pre-malignant state, colorectal adenoma.

  7. Soft X-ray beam induced current technique

    Energy Technology Data Exchange (ETDEWEB)

    Watts, B; Ade, H [Department of Physics, North Carolina State University, Raleigh, NC 27695 (United States); Queen, D; Hellman, F [Department of Physics, University of California, Berkeley, CA 94720 (United States); Kilcoyne, A L D; Tyliszczak, T, E-mail: benjamin.watts@gmail.co [Advanced Light Source, Lawrence Berkeley Nat. Lab., Berkeley, CA 94720 (United States)

    2009-09-01

    Direct mapping of the charge transport efficiency of polymer solar cell devices using a soft X-ray beam induced current (SoXBIC) method is described. By fabricating a polymer solar cell on an x-ray transparent substrate, we demonstrate the ability to map polymer composition and nanoscale structure within an operating solar cell device and to simultaneously measure the local charge transport efficiency via the short-circuit current. A simple model is calculated and compared to experimental SoXBIC data of a PFB:F8BT bulk-heterojunction device in order to gain greater insight into the device operation and physics.

  8. ELECTRIC MOTOR DIAGNOSTICS OF SWITCHES BASED ON THE NEURAL NETWORK DATA MODELING THE SPECTRAL DECOMPOSITION OF THE CURRENTS

    Directory of Open Access Journals (Sweden)

    O. M. Shvets

    2009-07-01

    Full Text Available The method of automated diagnostics of electric motors is offered. It uses a neural network revealing the electric motor faults on the basis of analysis of frequency spectrum of current flowing through the motor.

  9. Bulbar urethroplasty using the dorsal approach: current techniques

    Directory of Open Access Journals (Sweden)

    Barbagli Guido

    2003-01-01

    Full Text Available INTRODUCTION: The use of flaps or grafts is mandatory in patients with longer and complex strictures. In 1995-96 we described a new dorsal onlay graft urethroplasty. Over time, our original technique was better defined and changed. Now this procedure (also named Barbagli technique has been greeted with a fair amount of enthusiasm in Europe and in the United States. SURGICAL TECHNIQUE: The patient is placed in normal lithotomy position, and a midline perineo-scrotal incision is made. The bulbar urethra is then free from the bulbo-cavernous muscles, and is dissected from the corpora cavernosa. The urethra is completely mobilized from the corpora cavernosa, it is rotated 180 degrees, and is incised along its dorsal surface. The graft (preputial skin or buccal mucosa or the flap is fixed and quilted to the tunica albuginea of the corporal bodies. The right mucosal margin of the opened urethra is sutured to the right side of the patch-graft. The urethra is rotated back into its original position. The left urethral margin is sutured to the left side of the patch graft and to the corporal bodies, and the grafted area is entirely covered by the urethral plate. The bulbo-cavernous muscles are approximated over the grafted area. A 16F silicone Foley catheter is left in place. COMMENTS: Dorsal onlay graft urethroplasty is a versatile procedure that may be combined with various substitute materials like preputial skin, buccal mucosa grafts or pedicled flaps.

  10. REMOTE DIAGNOSTICS OF TURNOUTS STATE ON TIMING AND SPECTRAL COMPOSITION IN CURRENT CURVE

    Directory of Open Access Journals (Sweden)

    S. Yu. Buryak

    2015-03-01

    Full Text Available Purpose. Development and implementation the points system diagnostics that would allow determining remotely the current state of turnout with all possible faults, gradual and sudden failures, damages, and in real time to report about their appearance. Methodology. State diagnostics on the values analysis of turnout main parameters is proposed to carry out with the help of a computer and analog-to-digital converter (ADC. Connecting measurements performance is advisable to produce to a shunt ammeter, installed in the working circuit of the point feed panel. ADC converts the analog signal of lost volts at the shunt into digital form and transmits it to a computer which stores the received data on its own recording medium for their further processing and storage. There is special software that is capable to reconnect signal and construct its temporal characteristic as well as decompose it on the spectral components. Using it one can analyze the obtained data, which allows diagnosing state of points upon change the nature, values and composition of the current curve. Findings. The computer diagnosis method was confirmed in practice for possible indications of problems that are associated with both the mechanical part of the turnout and the electrical part of it, while controlling parameters such as the amount of current normal transition, when working on frictions, the duration of the transition, properly adjusted headset and attachment points, the state of the motor. Originality. The use of computer technology in the diagnosis of the state of turnouts during their operation to monitor the current values of technical indicators, analysis and storage for all types of electric switches with different types of engines both DC and AC occurs through digitization and recording signal from measuring shunt of point feeder panel. Practical value. The proposed method enables timely, still in the early stages of defect parts, damages or failures of nodes

  11. Application of RNB for high sensitive wear diagnostics in medicine technique and industry

    International Nuclear Information System (INIS)

    Fehsenfeld, P.; Eifrig, C.; Kubat, R.

    2002-01-01

    The RTM--Radionuclide Technique in Mechanical engineering--is now extended to the solution of world wide problems in medicine technique (prosthetics), and in development of modern materials (synthetic materials, ceramics, hard coatings, etc.) and their industrial application. RNB--Radioactive Nuclear Beams of 7 Be or 22 Na--may enable the required extreme thin radioactive surface labeling (several micrometers) of synthetic materials for wear measurements without producing radiation damages of influence to the wear properties of the material. The function principle and special properties of the RTM on-line wear diagnostics and its components, the measurement methods, the radioactive surface labeling, and the measurement instruments are explained. The quality features of a 7 Be and 22 Na-beam for RTM application are specified

  12. Development of a 2D temperature measurement technique for combustion diagnostics using 2-line atomic fluorescence

    Energy Technology Data Exchange (ETDEWEB)

    Engstroem, Johan

    2001-01-01

    The present thesis is concerned with the development and application of a novel planar laser-induced fluorescence (PLIF) technique for temperature measurements in a variety of combusting flows. Accurate measurement of temperature is an essential task in combustion diagnostics, since temperature is one of the most fundamental quantities for the characterization of combustion processes. The technique is based on two-line atomic fluorescence (TLAF) from small quantities of atomic indium (In) seeded into the fuel. It has been developed from small-scale experiments in laboratory flames to the point where practical combustion systems can be studied. The technique is conceptually simple and reveals temperature information in the post-flame regions. The viability of the technique has been tested in three extreme measurement situations: in spark ignition engine combustion, in ultra-lean combustion situations such as lean burning aero-engine concepts and, finally, in fuel-rich combustion. TLAF was successfully applied in an optical Sl engine using isooctane as fuel. The wide temperature sensitivity, 700 - 3000 K, of the technique using indium atoms allowed measurements over the entire combustion cycle in the engine to be performed. In applications in lean combustion a potential problem caused by the strong oxidation processes of indium atoms was encountered. This limits measurement times due to deposits of absorbing indium oxide on measurement windows. The seeding requirement is a disadvantage of the technique and can be a limitation in some applications. The results from experiments performed in sooting flames are very promising for thermometry measurements in such environments. Absorption by hydrocarbons and other native species was found to be negligible. Since low laser energies and low seeding concentrations could be used, the technique did not, unlike most other incoherent optical thermometry techniques, suffer interferences from LII of soot particles or LIF from PAH

  13. A study on the fault diagnostic techniques for reactor internal structures using neutron noise analysis

    International Nuclear Information System (INIS)

    Kim, Tae Ryong; Jeong, Seong Ho; Park, Jin Ho; Park, Jin Suk

    1994-08-01

    The unfavorable phenomena, such as flow induced vibration and aging process in reactor internals, cause degradation of structural integrity and may result in loosing some mechanical binding components which might impact other equipments and components or cause flow blockage. Since these malfunctions and potential failures change reactor noise signal, it is necessary to analyze reactor noise signal for early fault diagnosis in the point of few of safety and plant economics. The objectives of this study are to establish fault diagnostic and TS(thermal shield), and to develop a data acquisition and signal processing software system. In the first year of this study, an analysis technique for the reactor internal vibration using the reactor noise was proposed. With the technique proposed and the reactor noise signals (ex-core neutron and acceleration), the dynamic characteristics of Ulchin-1 reactor internals were obtained, and compared with those of Tricastin-1 which is the prototype of Ulchin-1. In the second year, a PC-based expert system for reactor internals fault diagnosis is developed, which included data acquisition, signal processing, feature extraction function, and represented diagnostic knowledge by the IF-THEN rule. To know the effect of the faults, the reactor internals of Ulchin-1 is modeled using FEM and simulated with an artificial defect given in the hold-down spring. Trend in the dynamic characteristics of reactor internals is also observed during one fuel cycle to know the effect of boron concentration. 100 figs, 7 tabs, 18 refs. (Author)

  14. The Role of Flow Diagnostic Techniques in Fan and Open Rotor Noise Modeling

    Science.gov (United States)

    Envia, Edmane

    2016-01-01

    A principal source of turbomachinery noise is the interaction of the rotating and stationary blade rows with the perturbations in the airstream through the engine. As such, a lot of research has been devoted to the study of the turbomachinery noise generation mechanisms. This is particularly true of fan and open rotors, both of which are the major contributors to the overall noise output of modern aircraft engines. Much of the research in fan and open rotor noise has been focused on developing theoretical models for predicting their noise characteristics. These models, which run the gamut from the semi-empirical to fully computational ones, are, in one form or another, informed by the description of the unsteady flow-field in which the propulsors (i.e., the fan and open rotors) operate. Not surprisingly, the fidelity of the theoretical models is dependent, to a large extent, on capturing the nuances of the unsteady flowfield that have a direct role in the noise generation process. As such, flow diagnostic techniques have proven to be indispensible in identifying the shortcoming of theoretical models and in helping to improve them. This presentation will provide a few examples of the role of flow diagnostic techniques in assessing the fidelity and robustness of the fan and open rotor noise prediction models.

  15. [Application of molecular diagnostic techniques in precision medicine of personalized treatment for colorectal cancer].

    Science.gov (United States)

    Fu, Ji; Lin, Guole

    2016-01-01

    Precision medicine is to customize the treatment options for individual patient based on the personal genome information. Colorectal cancer (CRC) is one of the most common cancer worldwide. Molecular heterogeneity of CRC, which includes the MSI phenotype, hypermutation phenotype, and their relationship with clinical preferences, is believed to be one of the main factors responsible for the considerable variability in treatment response. The development of powerful next-generation sequencing (NGS) technologies allows us to further understand the biological behavior of colorectal cancer, and to analyze the prognosis and chemotherapeutic drug reactions by molecular diagnostic techniques, which can guide the clinical treatment. This paper will introduce the new findings in this field. Meanwhile we integrate the new progress of key pathways including EGFR, RAS, PI3K/AKT and VEGF, and the experience in selective patients through associated molecular diagnostic screening who gain better efficacy after target therapy. The technique for detecting circulating tumor DNA (ctDNA) is introduced here as well, which can identify patients with high risk for recurrence, and demonstrate the risk of chemotherapy resistance. Mechanism of tumor drug resistance may be revealed by dynamic observation of gene alteration during treatment.

  16. Chest trauma in children: current imaging guidelines and techniques.

    LENUS (Irish Health Repository)

    Moore, Michael A

    2011-09-01

    Given the heterogeneous nature of pediatric chest trauma, the optimal imaging approach is tailored to the specific patient. Chest radiography remains the most important imaging modality for initial triage. The decision to perform a chest computed tomography scan should be based on the nature of the trauma, the child\\'s clinical condition, and the initial radiographic findings, taking the age-related pretest probabilities of serious injury into account. The principles of as low as reasonably achievable and Image Gently should be followed. The epidemiology and pathophysiology, imaging techniques, characteristic findings, and evidence-based algorithms for pediatric chest trauma are discussed.

  17. Surface inspection technique with an eddy current testing array probe

    International Nuclear Information System (INIS)

    Nishimizu, Akira; Endo, Hisashi; Tooma, Masahiro; Otani, Kenichi; Ouchi, Hirofumi; Yoshida, Isao; Nonaka, Yoshio

    2010-01-01

    An eddy current testing (ECT) system has been developed for inspecting weld surfaces of components in the reactor pressure vessel of nuclear plants. The system can be applied to curved surfaces with an ECT array probe, it can discriminate flaws from other signal factors by using a combination of arrayed coils signal-phase. The system is applied to a mock-up of core internal components and the signal discrimination using the signal-phase clearly separated flaw and noise signals. (author)

  18. Magnetic Diagnostics for Equilibrium Reconstructions in the Presence of Nonaxisymmetric Eddy Current Distributions in Tokamaks

    International Nuclear Information System (INIS)

    Kaita, R.; Kozub, T.; Logan, N.; Majeski, R.; Menard, J.; Zakharov, L.

    2010-01-01

    The lithium tokamak experiment (LTX) is a modest-sized spherical tokamak (R 0 = 0.4 m and a = 0.26 m) designed to investigate the low-recycling lithium wall operating regime for magnetically confined plasmas. LTX will reach this regime through a lithium-coated shell internal to the vacuum vessel, conformal to the plasma last-closed-flux surface, and heated to 300-400 C. This structure is highly conductive and not axisymmetric. The three-dimensional nature of the shell causes the eddy currents and magnetic fields to be three-dimensional as well. In order to analyze the plasma equilibrium in the presence of three-dimensional eddy currents, an extensive array of unique magnetic diagnostics has been implemented. Sensors are designed to survive high temperatures and incidental contact with lithium and provide data on toroidal asymmetries as well as full coverage of the poloidal cross-section. The magnetic array has been utilized to determine the effects of nonaxisymmetric eddy currents and to model the start-up phase of LTX. Measurements from the magnetic array, coupled with two-dimensional field component modeling, have allowed a suitable field null and initial plasma current to be produced. For full magnetic reconstructions, a three-dimensional electromagnetic model of the vacuum vessel and shell is under development.

  19. Mammary carcinoma – current diagnostic methods and symptomatology in imaging studies

    International Nuclear Information System (INIS)

    Popiel, Monika; Mróz-Klimas, Danuta; Kasprzak, Renata; Furmanek, Mariusz

    2012-01-01

    Breast cancer is the most common neoplasm of the female population and its incidence is constantly rising. Social campaigns educating the public about the importance of the problem have been conducted for the past several years. Women are encouraged to self-examine on a monthly basis. Women aged 50–69 years can have an x-ray mammography performed once every 2 years as part of a prophylactic screening program. Ultrasound studies or MR mammography are adjuvant or, in some cases, alternative to x-ray mammography. Nuclear medicine techniques with application of oncophilic markers and receptor studies (this publication will not cover nuclear medicine methods) are not routinely used. Other techniques, such as computed tomography and conventional radiography are of no significance in the diagnostics of mammary cancer. However, together with isotopic methods, they are helpful in staging of the disease. X-ray mammography is, up to date, the only method with proven value in decreasing mortality. It is also the best available method for visualization of microcalicifications. Ultrasound examination is complementary to x-ray mammography as it is a cheap, easily available method of imaging mammary glands with higher glandular tissue content. It is also the most commonly used modality aiding in targeted biopsy of mammary gland. To date, MR mammography, characterized by the highest sensitivity in cancer diagnostics, remained a method reserved for “special tasks”. MR is used for prophylaxis mainly in a population of women with particularly high risk of the disease and in cases where x-ray and ultrasound examinations are insufficient. Picture of mammary carcinoma in imaging studies is heterogeneous. However, it most often presents as an irregularly demarcated mass. Moreover, each modality can aid in visualization of additional features of a lesion such as typical shape of microcalcifications in x-ray mammography, characteristic pattern of contrast enhancement in MR examination

  20. Alternating current techniques for corrosion monitoring in water reactor systems

    International Nuclear Information System (INIS)

    Isaacs, H.S.; Weeks, J.R.

    1977-01-01

    Corrosion in both nuclear and fossil fueled steam generators is generally a consequence of the presence of aggressive impurities introduced into the coolant system through condenser leakage. The impurities concentrate in regions of the steam generator protected from coolant flow, in crevices or under deposited corrosion products and adjacent to heat transfer surfaces. These three factors, the aggressive impurity, crevice type areas and heat transfer surfaces appear to be the requirements for the onset of rapid corrosion. Under conditions where coolant impurities do not concentrate the corrosion rates are low, easily measured and can be accounted for by allowances in the design of the steam generator. Rapid corrosion conditions cannot be designed for and must be suppressed. The condition of the surfaces when rapid corrosion develops must be markedly different from those during normal operation and these changes should be observable using electrochemical techniques. This background formed the basis of a design of a corrosion monitoring device, work on which was initiated at BNL. The basic principles of the technique are described. The object of the work is to develop a corrosion monitoring device which can be operated with PWR steam generator secondary coolant feed water

  1. Skeletal muscle proteomics: current approaches, technical challenges and emerging techniques

    LENUS (Irish Health Repository)

    Ohlendieck, Kay

    2011-02-01

    Abstract Background Skeletal muscle fibres represent one of the most abundant cell types in mammals. Their highly specialised contractile and metabolic functions depend on a large number of membrane-associated proteins with very high molecular masses, proteins with extensive posttranslational modifications and components that exist in highly complex supramolecular structures. This makes it extremely difficult to perform conventional biochemical studies of potential changes in protein clusters during physiological adaptations or pathological processes. Results Skeletal muscle proteomics attempts to establish the global identification and biochemical characterisation of all members of the muscle-associated protein complement. A considerable number of proteomic studies have employed large-scale separation techniques, such as high-resolution two-dimensional gel electrophoresis or liquid chromatography, and combined them with mass spectrometry as the method of choice for high-throughput protein identification. Muscle proteomics has been applied to the comprehensive biochemical profiling of developing, maturing and aging muscle, as well as the analysis of contractile tissues undergoing physiological adaptations seen in disuse atrophy, physical exercise and chronic muscle transformation. Biomedical investigations into proteome-wide alterations in skeletal muscle tissues were also used to establish novel biomarker signatures of neuromuscular disorders. Importantly, mass spectrometric studies have confirmed the enormous complexity of posttranslational modifications in skeletal muscle proteins. Conclusions This review critically examines the scientific impact of modern muscle proteomics and discusses its successful application for a better understanding of muscle biology, but also outlines its technical limitations and emerging techniques to establish new biomarker candidates.

  2. Emerging optical techniques in advanced cystoscopy for bladder cancer diagnosis: A review of the current literature

    NARCIS (Netherlands)

    Cauberg Evelyne, C. C.; de La Rosette, Jean J. M. C. H.; de Reijke, Theo M.

    2011-01-01

    The current standard for the diagnosis and followup of bladder cancer remains white light cystoscopy, despite its well-known limitations. The aim of this paper is to review the current literature on three optical diagnostics that have been developed to improve the performance of white light

  3. Molecular Diagnostics for Precision Medicine in Colorectal Cancer: Current Status and Future Perspective

    Directory of Open Access Journals (Sweden)

    Guoli Chen

    2016-01-01

    Full Text Available Precision medicine, a concept that has recently emerged and has been widely discussed, emphasizes tailoring medical care to individuals largely based on information acquired from molecular diagnostic testing. As a vital aspect of precision cancer medicine, targeted therapy has been proven to be efficacious and less toxic for cancer treatment. Colorectal cancer (CRC is one of the most common cancers and among the leading causes for cancer related deaths in the United States and worldwide. By far, CRC has been one of the most successful examples in the field of precision cancer medicine, applying molecular tests to guide targeted therapy. In this review, we summarize the current guidelines for anti-EGFR therapy, revisit the roles of pathologists in an era of precision cancer medicine, demonstrate the transition from traditional “one test-one drug” assays to multiplex assays, especially by using next-generation sequencing platforms in the clinical diagnostic laboratories, and discuss the future perspectives of tumor heterogeneity associated with anti-EGFR resistance and immune checkpoint blockage therapy in CRC.

  4. Molecular Diagnostics for Precision Medicine in Colorectal Cancer: Current Status and Future Perspective.

    Science.gov (United States)

    Chen, Guoli; Yang, Zhaohai; Eshleman, James R; Netto, George J; Lin, Ming-Tseh

    2016-01-01

    Precision medicine, a concept that has recently emerged and has been widely discussed, emphasizes tailoring medical care to individuals largely based on information acquired from molecular diagnostic testing. As a vital aspect of precision cancer medicine, targeted therapy has been proven to be efficacious and less toxic for cancer treatment. Colorectal cancer (CRC) is one of the most common cancers and among the leading causes for cancer related deaths in the United States and worldwide. By far, CRC has been one of the most successful examples in the field of precision cancer medicine, applying molecular tests to guide targeted therapy. In this review, we summarize the current guidelines for anti-EGFR therapy, revisit the roles of pathologists in an era of precision cancer medicine, demonstrate the transition from traditional "one test-one drug" assays to multiplex assays, especially by using next-generation sequencing platforms in the clinical diagnostic laboratories, and discuss the future perspectives of tumor heterogeneity associated with anti-EGFR resistance and immune checkpoint blockage therapy in CRC.

  5. Characterization of irradiated fuel rods using pulsed eddy current techniques

    International Nuclear Information System (INIS)

    Martin, M.R.; Francis, W.C.

    1975-11-01

    A number of irradiated fuel rods and unfueled zircaloy cladding tubes (''water tubes'') were obtained from the Saxton reactor through arrangements with the Westinghouse Electric Corporation for use in subsequent irradiation effects and fuel behavior programs. A comprehensive nondestructive and corroborative destructive characterization program was undertaken on these fuel rods and tubes by ANC to provide baseline data on their characteristics prior to further testing and for comparison against post-post data. This report deals primarily with one portion of the NDT program performed remotely in the hot cells. The portion of interest in this paper is the pulsed eddy current inspection used in the nondestructive phase of the work. 6 references

  6. Comparing Symptoms of Autism Spectrum Disorders Using the Current "DSM-IV-TR" Diagnostic Criteria and the Proposed "DSM-V" Diagnostic Criteria

    Science.gov (United States)

    Worley, Julie A.; Matson, Johnny L.

    2012-01-01

    The American Psychiatric Association has proposed major revisions for the diagnostic category encompassing Autism Spectrum Disorders (ASD), which will reportedly increase the specificity and maintain the sensitivity of diagnoses. As a result, the aim of the current study was to compare symptoms of ASD in children and adolescents (N = 208) who met…

  7. Childhood Enuresis: Current Diagnostic Formulations, Salient Findings, and Effective Treatment Modalities.

    Science.gov (United States)

    Thurber, Steven

    2017-06-01

    Enuresis constitutes a frequently encountered problem area for children that may adversely affect social and emotional adjustment. This type of incontinence has been of concern to the human family for centuries. A brief history of enuresis is presented followed by current conceptualizations, diagnostic criteria, prevalence rates and psychiatric comorbidities. Historic notions of causation together with ineffective, sometimes barbaric treatments are then discussed, ending with a presentation of evidence-based treatment modalities, with the urine alarm being an essential element of effective treatment. An intervention termed dry bed training combines the urine alarm with a series of procedures designed in part to reduce relapse potential and should be a primary consideration for implementation by treatment professionals. Finally, a brief case study is presented illustrating special etiological and treatment considerations with juvenile psychiatric patients. Copyright © 2016 Elsevier Inc. All rights reserved.

  8. Current and future molecular diagnostics in non-small-cell lung cancer.

    Science.gov (United States)

    Li, Chun Man; Chu, Wing Ying; Wong, Di Lun; Tsang, Hin Fung; Tsui, Nancy Bo Yin; Chan, Charles Ming Lok; Xue, Vivian Wei Wen; Siu, Parco Ming Fai; Yung, Benjamin Yat Ming; Chan, Lawrence Wing Chi; Wong, Sze Chuen Cesar

    2015-01-01

    The molecular investigation of lung cancer has opened up an advanced area for the diagnosis and therapeutic management of lung cancer patients. Gene alterations in cancer initiation and progression provide not only information on molecular changes in lung cancer but also opportunities in advanced therapeutic regime by personalized targeted therapy. EGFR mutations and ALK rearrangement are important predictive biomarkers for the efficiency of tyrosine kinase inhibitor treatment in lung cancer patients. Moreover, epigenetic aberration and microRNA dysregulation are recent advances in the early detection and monitoring of lung cancer. Although a wide range of molecular tests are available, standardization and validation of assay protocols are essential for the quality of the test outcome. In this review, current and new advancements of molecular biomarkers for non-small-cell lung cancer will be discussed. Recommendations on future development of molecular diagnostic services will also be explored.

  9. A review of current radiation protection in radiological diagnostics in Montenegro

    International Nuclear Information System (INIS)

    Mijovic, Slavoljub; Kovacevic, Zarko; Vuceljic, Mira; Scepanovic, Mara; Picuric, Ivana; Mardjokic, Aleksandar

    2008-01-01

    After getting independence 2006 year and became 192nd member of UN, Montenegro state is conducting measures for radiation protection autonomously. Because of complexity of such issues, Montenegro faced a lot of problems: lack of a national legal system in this field, expertise, appropriate equipments etc. Some estimates have shown that the major exposures of populations in Montenegro to ionizing radiation are due to the medical care. The purpose of this work is to analyze current protection in radiological diagnostics in Montenegro and compare it with international standards. It could be clearly stated where they are in agreement or disagreement. The method of analyzing is a holistic one, starting from the law, regulations and decisions through the protocols of quality controls and finishing with the reports and database of important parameters and data. The main findings are stated as follows: although the current radiation protection in radiological diagnostics is conducting according the law of former Federal Republic of Yugoslavia (FRY) and its regulations and decisions, the overall legal system is still satisfactory; Identification and location of radiation sources through a system of notification and maintaining a national inventory is not satisfactory; There are a lack of expertise and equipments for the technical services, although the procedures and protocols of the quality control are at a satisfactory level; There is a lack of knowledge of professional staff working in this field. The practice is sometimes operated carelessly; The patients protection is satisfactory but there is not care to decrease a level of exposure according the ALARA principle. (author)

  10. Comparison of current tonometry techniques in measurement of intraocular pressure.

    Science.gov (United States)

    Kouchaki, Behrooz; Hashemi, Hassan; Yekta, Abbasali; Khabazkhoob, Mehdi

    2017-06-01

    To compare four tonometry techniques: Goldmann applanation tonometer (GAT), Dynamic contour tonometer (DCT), Non-contact tonometer (NCT), and Ocular Response Analyzer (ORA) in the measurement of intraocular pressure (IOP) and the impact of some corneal biomechanical factors on their performance. In this cross-sectional study, volunteers with normal ophthalmic examination and no history of eye surgery (except for uncomplicated cataract surgery) or trauma were selected. Twenty-five subjects were male, and 21 were female. The mean age was 48 ± 19.2 years. Anterior segment parameters were measured with Scheimpflug imaging. IOP was measured with GAT, DCT, NCT, and ORA in random order. A 95% limit of agreement of IOPs was analyzed. The impact of different parameters on the measured IOP with each device was evaluated by regression analysis. The average IOP measured with GAT, DCT, NCT, and ORA was 16.4 ± 3.5, 18.1 ± 3.4, 16.2 ± 3.9, and 17.3 ± 3.4 mmHg, respectively. The difference of IOP measured with NCT and GAT was not significant ( P  = 0.382). Intraocular pressure was significantly different between GAT with DCT and IOP CC ( P  tonometers.

  11. Endoluminal weight loss and metabolic therapies: current and future techniques.

    Science.gov (United States)

    Hill, Christine; Khashab, Mouen A; Kalloo, Anthony N; Kumbhari, Vivek

    2018-01-01

    Obesity is a public health epidemic associated with a number of comorbidities, most notably type 2 diabetes and hypertension, as well as elevated all-cause mortality. The treatment for obesity and its associated comorbidities has most recently expanded into the field of bariatric endoscopy. This field bridges a gap between lifestyle counseling with or without pharmaceutical treatment and the most effective treatment of obesity, bariatric surgery. Because of its minimally invasive nature, bariatric endoscopic therapy has the potential to appeal to the large sector of the obese population that resists surgery, as well as those early in the onset of obesity. To date, five endoscopic devices have been approved by the U.S. Food and Drug Administration for the treatment of obesity, and many more are in development, undergoing clinical trials, or being used around the world. Here, we present the current state of the field, highlight recent developments, and describe the clinical outcomes of these minimally invasive procedures in terms of weight loss, improvement in metabolic profile, and reduction in comorbidities. © 2017 New York Academy of Sciences.

  12. Evaluation of Temporal Diagnostic Techniques for Two-Bunch Facet Beam

    Energy Technology Data Exchange (ETDEWEB)

    Litos, M.D.; Bionta, M.R.; Dolgashev, V.A.; England, R.J.; Fritz, D.; Gilevich, S.; Hering, Ph.; Hogan, M.J.; /SLAC

    2011-08-19

    Three temporal diagnostic techniques are considered for use in the FACET facility at SLAC, which will incorporate a unique two-bunch beam for plasma wakefield acceleration experiments. The results of these experiments will depend strongly on the the inter-bunch spacing as well as the longitudinal profiles of the two bunches. A reliable, singleshot, high resolution measurement of the beam's temporal profile is necessary to fully quantify the physical mechanisms underlying the beam driven plasma wakefield acceleration. In this study we show that a transverse deflecting cavity is the diagnostic which best meets our criteria. Based on our laboratory testing, numerical calculations, and simulations of the three single-shot temporal diagnostic devices, the X-band TCAV system is the best candidate for resolving FACET's two-bunch beam, with an estimated resolution of 7 {micro}m. Both the S-band TCAV system and the EO system could resolve the peak-to-peak separation of the two bunches in the FACET beam with estimated resolutions of 25 {micro}m and 30 {micro}m, respectively, but would be unable to resolve the temporal profiles of the individual bunches themselves. Because the TCAV signal is more easily interpreted and because the reliability of the EO system is less well known, however, the S-band TCAV system would be the next preferred option after the X-band TCAV system. The Fesca-200 streak camera, though simple, compact, and reliable, is unable to achieve a resolution that would be of use to FACET.

  13. Upgrades of Diagnostic Techniques and Technologies for JET next D-T Campaigns

    Energy Technology Data Exchange (ETDEWEB)

    Murari, Andrea [Consorzio RFX - CNR, ENEA, INFN, Universita di Padova, Acciaierie Venete SpA,Corso Stati Uniti 4, 35127 Padova (Italy)

    2015-07-01

    . With regard to the fusion products, JET now can deploy a consistent set of techniques to measure the neutron yield and neutron spectra and to diagnose the fast particles. A full calibration of the neutron diagnostics with a 14 MeV source is being considered, after the recent very successful calibration for the 2.45 MeV neutrons. Vertical and horizontal lines of sight are foreseen for neutron and gamma spectrometry, in order to better determine the thermal neutron yield and to separate the trapped and passing components of the alphas. Various gamma ray spectrometers are being developed to cover all the various operational scenarios, from trace tritium to 50-50 D-T operation. The redistribution of the alphas will be measured with the gamma ray cameras, recently upgraded with full digital electronics; new detectors are being considered to bring the time resolution of the system in the ten of ms range. The lost alphas will also be diagnosed with improved spatial and temporal resolution, using Faraday cups and a scintillator probe. From a technological perspective, the D-T campaign will provide a unique opportunity to test ITER relevant technologies. From radiation hard detectors, for example Hall probes, to neutron absorbers and to shielding concepts, the potential of various solutions in a realistic 14 MeV radiation field will be assessed. The effects of neutrons and gamma on ancillary technologies and systems, such as fibre optics and electronics circuits, are also expected to be sufficiently high to derive useful information about the competitive advantage of various alternatives.

  14. A novel non-invasive diagnostic sampling technique for cutaneous leishmaniasis.

    Directory of Open Access Journals (Sweden)

    Yasaman Taslimi

    2017-07-01

    Full Text Available Accurate diagnosis of cutaneous leishmaniasis (CL is important for chemotherapy and epidemiological studies. Common approaches for Leishmania detection involve the invasive collection of specimens for direct identification of amastigotes by microscopy and the culturing of promastigotes from infected tissues. Although these techniques are highly specific, they require highly skilled health workers and have the inherent risks of all invasive procedures, such as pain and risk of bacterial and fungal super-infection. Therefore, it is essential to reduce discomfort, potential infection and scarring caused by invasive diagnostic approaches especially for children. In this report, we present a novel non-invasive method, that is painless, rapid and user-friendly, using sequential tape strips for sampling and isolation of DNA from the surface of active and healed skin lesions of CL patients. A total of 119 patients suspected of suffering from cutaneous leishmaniasis with different clinical manifestations were recruited and samples were collected both from their lesions and from uninfected areas. In addition, 15 fungal-infected lesions and 54 areas of healthy skin were examined. The duration of sampling is short (less than one minute and species identification by PCR is highly specific and sensitive. The sequential tape stripping sampling method is a sensitive, non-invasive and cost-effective alternative to traditional diagnostic assays and it is suitable for field studies as well as for use in health care centers.

  15. Diagnostic evaluation of rolling behavior in ball bearings by ultrasonic technique

    International Nuclear Information System (INIS)

    Wakabayashi, T

    2012-01-01

    Failures of machines having rotating parts are mostly caused by damage to bearings and there exist increasing demands for detecting damaged bearings at an early stage. However, conventional diagnostic methods, such as measuring temperature and observing vibration, have found difficulties in performing the early detection, so that more advanced diagnosis is necessary. This study therefore applies an ultrasonic technique as an advanced diagnostic method to bearing life tests. Ultrasonic wave pulses (UWP) emitted from a piezoelectric UWP generator can partially reflect from the interfaces of contact zones within the housing and the bearing with regard to the different acoustic impedance between a solid-to-solid contact and a contact dominated by some fluid layers. Hence, the intensity of the resultant UWP echoes can be determined by the real contact area formed at the interfaces. The experimental results of UWP echoes under the different operating conditions have demonstrated that the time intervals between peaks of UWP echoes varied in accordance with the movement of rolling balls and the lubricating phenomena in bearings. This behavior has further suggested the possibility of the early detection of abnormalities in ball bearings by using the variation in UWP echoes.

  16. Evaluation of diagnostic technique for degradation of low-voltage electric cables with silicone rubber insulator

    International Nuclear Information System (INIS)

    Mikami, Masao

    2005-01-01

    As a part of countermeasures against ageing problems of nuclear power plants, it is requested to establish non-destructive diagnostic technique for their degradation of low voltage electric cables and assessment standard of their life. Having aimed at investigating the degradation of low-voltage electric cable with silicone rubber insulator, change of its surface hardness at elevated temperature were measured by indenter modules. Moreover, we also measured the elongation at break, which is regarded as general degradation index of electric cables, and the surface hardness with a micro hardness meter. Consequently, it is seen that the indenter modulus measurement is (1) capable to obtain general feature of the thermal degradation of silicone rubber insulator, (2) applicable to diagnose the degree of degradation of the electric cable by converting the result to elongation at break, (3) well correlated with the hardness measurement of the electric cable with the micro hardness meter. (author)

  17. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Science.gov (United States)

    Saha, Bhaskar; Goebel, kai

    2007-01-01

    Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and theoretically sound approach to the modern Condition- Based Maintenance (CBM)/Prognostic Health Management (PHM) paradigm. The application of the Bayesian techniques to regression and classification in the form of Relevance Vector Machine (RVM), and to state estimation as in Particle Filters (PF), provides a powerful tool to integrate the diagnosis and prognosis of battery health. The RVM, which is a Bayesian treatment of the Support Vector Machine (SVM), is used for model identification, while the PF framework uses the learnt model, statistical estimates of noise and anticipated operational conditions to provide estimates of remaining useful life (RUL) in the form of a probability density function (PDF). This type of prognostics generates a significant value addition to the management of any operation involving electrical systems.

  18. IERIAS: inference engine for reactor accident diagnostic system using knowledge engineering technique

    International Nuclear Information System (INIS)

    Yokobayashi, Masao; Yoshida, Kazuo; Kohsaka, Atsuo; Yamamoto, Minoru.

    1984-11-01

    This report describes an inference engine IERIAS which has been devoloped for a diagnostic system to identify the cause and type of an abnormal transient of a reactor plant. This system using knowledge engineering technique consists of a knowledge base and an inference engine. The inference engine IERIAS is designed so as to treat time-varying data of a plant. The major features of IERIAS are ; (1) histroy of transients can be treated, (2) knowledge base can be divided into some knowledge units, (3) program language UTILISP is used which is suitable for symbolic data manipulation. Inference was made using IERIAS with a knowledge base which was created from simulated results of various transients by a PWR plant simulator. The results showed a good applicability of IERIAS for reactor diagnosis. (author)

  19. New Diagnostic, Launch and Model Control Techniques in the NASA Ames HFFAF Ballistic Range

    Science.gov (United States)

    Bogdanoff, David W.

    2012-01-01

    This report presents new diagnostic, launch and model control techniques used in the NASA Ames HFFAF ballistic range. High speed movies were used to view the sabot separation process and the passage of the model through the model splap paper. Cavities in the rear of the sabot, to catch the muzzle blast of the gun, were used to control sabot finger separation angles and distances. Inserts were installed in the powder chamber to greatly reduce the ullage volume (empty space) in the chamber. This resulted in much more complete and repeatable combustion of the powder and hence, in much more repeatable muzzle velocities. Sheets of paper or cardstock, impacting one half of the model, were used to control the amplitudes of the model pitch oscillations.

  20. Probabilistic techniques using Monte Carlo sampling for multi- component system diagnostics

    International Nuclear Information System (INIS)

    Aumeier, S.E.; Lee, J.C.; Akcasu, A.Z.

    1995-01-01

    We outline the structure of a new approach at multi-component system fault diagnostics which utilizes detailed system simulation models, uncertain system observation data, statistical knowledge of system parameters, expert opinion, and component reliability data in an effort to identify incipient component performance degradations of arbitrary number and magnitude. The technique involves the use of multiple adaptive Kalman filters for fault estimation, the results of which are screened using standard hypothesis testing procedures to define a set of component events that could have transpired. Latin Hypercube sample each of these feasible component events in terms of uncertain component reliability data and filter estimates. The capabilities of the procedure are demonstrated through the analysis of a simulated small magnitude binary component fault in a boiling water reactor balance of plant. The results show that the procedure has the potential to be a very effective tool for incipient component fault diagnosis

  1. Reducing beam shaper alignment complexity: diagnostic techniques for alignment and tuning

    Science.gov (United States)

    Lizotte, Todd E.

    2011-10-01

    Safe and efficient optical alignment is a critical requirement for industrial laser systems used in a high volume manufacturing environment. Of specific interest is the development of techniques to align beam shaping optics within a beam line; having the ability to instantly verify by a qualitative means that each element is in its proper position as the beam shaper module is being aligned. There is a need to reduce these types of alignment techniques down to a level where even a newbie to optical alignment will be able to complete the task. Couple this alignment need with the fact that most laser system manufacturers ship their products worldwide and the introduction of a new set of variables including cultural and language barriers, makes this a top priority for manufacturers. Tools and methodologies for alignment of complex optical systems need to be able to cross these barriers to ensure the highest degree of up time and reduce the cost of maintenance on the production floor. Customers worldwide, who purchase production laser equipment, understand that the majority of costs to a manufacturing facility is spent on system maintenance and is typically the largest single controllable expenditure in a production plant. This desire to reduce costs is driving the trend these days towards predictive and proactive, not reactive maintenance of laser based optical beam delivery systems [10]. With proper diagnostic tools, laser system developers can develop proactive approaches to reduce system down time, safe guard operational performance and reduce premature or catastrophic optics failures. Obviously analytical data will provide quantifiable performance standards which are more precise than qualitative standards, but each have a role in determining overall optical system performance [10]. This paper will discuss the use of film and fluorescent mirror devices as diagnostic tools for beam shaper module alignment off line or in-situ. The paper will also provide an overview

  2. Performance and Pain Tolerability of Current Diagnostic Allergy Skin Prick Test Devices.

    Science.gov (United States)

    Tversky, Jody R; Chelladurai, Yohalakshmi; McGready, John; Hamilton, Robert G

    2015-01-01

    Allergen skin prick testing remains an essential tool for diagnosing atopic disease and guiding treatment. Sensitivity needs to be defined for newly introduced devices. Our aim was to compare the performance of 10 current allergy skin prick test devices. Single- and multiheaded skin test devices (n = 10) were applied by a single operator in a prospective randomized manner. Histamine (1 and 6 mg/mL) and control diluent were introduced at 6 randomized locations onto the upper and lower arms of healthy subjects. Wheal and flare reactions were measured independently by 2 masked technicians. Twenty-four subjects provided consent, and 768 skin tests were placed. Mean wheal diameter among devices differed from 3.0 mm (ComforTen; Hollister-Stier, Spokane, Wash) to 6.8 mm (UniTest PC; Lincoln Diagnostics, Decatur, Ill) using 1 mg/mL histamine (P Diagnostics, Decatur, Ill; and Sharp-Test; Panatrex, Placentia, Calif) using 6 mg/mL histamine (P pain score of less than 4 on a 10-point visual analog scale. Pain scores were higher among women, but this did not reach statistical significance. The Multi-Test PC and the UniTest PC had the lowest pain scores compared with the other devices. All 10 skin prick test devices displayed good analytical sensitivity and specificity; however, 3 mm cannot arbitrarily be used as a positive threshold. The use of histamine at 1 mg/mL is unacceptable for certain devices but may be preferable for the most sensitive devices. On average, there was no pain score difference between multiheaded and single-head devices. Copyright © 2015 American Academy of Allergy, Asthma & Immunology. Published by Elsevier Inc. All rights reserved.

  3. Sporadic Creutzfeldt-Jakob disease with focal findings: caveats to current diagnostic criteria

    Science.gov (United States)

    Mader, Edward C.; El-Abassi, Rima; Villemarette-Pittman, Nicole R.; Santana-Gould, Lenay; Olejniczak, Piotr W.; England, John D.

    2013-01-01

    The clinical diagnosis of Creutzfeldt-Jakob disease (CJD) is largely based on the 1998 World Health Organization diagnostic criteria. Unfortunately, rigid compliance with these criteria may result in failure to recognize sporadic CJD (sCJD), especially early in its course when focal findings predominate and traditional red flags are not yet present. A 61-year-old man presented with a 3-week history of epilepsia partialis continua (jerking of the left upper extremity) and a 2-week history of forgetfulness and left hemiparesis; left hemisensory neglect was also detected on admission. Repeated brain magnetic resonance imaging (MRI) showed areas of restricted diffusion in the cerebral cortex, initially on the right but later spreading to the left. Electroence-phalography (EEG) on hospital days 7, 10, and 14 showed right-sided periodic lateralized epileptiform discharges. On day 20, the EEG showed periodic sharp wave complexes leading to a diagnosis of probable sCJD and subsequently to definite sCJD with brain biopsy. Neurological decline was relatively fast with generalized myoclonus and akinetic mutism developing within 7 weeks from the onset of illness. CJD was not immediately recognized because of the patient's focal/lateralized manifestations. Focal/lateralized clinical, EEG, and MRI findings are not uncommon in sCJD and EEG/MRI results may not be diagnostic in the early stages of sCJD. Familiarity with these caveats and with the most current criteria for diagnosing probable sCJD (University of California San Francisco 2007, MRI-CJD Consortium 2009) will enhance the ability to recognize sCJD and implement early safety measures. PMID:23717780

  4. PET motion correction in context of integrated PET/MR: Current techniques, limitations, and future projections.

    Science.gov (United States)

    Gillman, Ashley; Smith, Jye; Thomas, Paul; Rose, Stephen; Dowson, Nicholas

    2017-12-01

    Patient motion is an important consideration in modern PET image reconstruction. Advances in PET technology mean motion has an increasingly important influence on resulting image quality. Motion-induced artifacts can have adverse effects on clinical outcomes, including missed diagnoses and oversized radiotherapy treatment volumes. This review aims to summarize the wide variety of motion correction techniques available in PET and combined PET/CT and PET/MR, with a focus on the latter. A general framework for the motion correction of PET images is presented, consisting of acquisition, modeling, and correction stages. Methods for measuring, modeling, and correcting motion and associated artifacts, both in literature and commercially available, are presented, and their relative merits are contrasted. Identified limitations of current methods include modeling of aperiodic and/or unpredictable motion, attaining adequate temporal resolution for motion correction in dynamic kinetic modeling acquisitions, and maintaining availability of the MR in PET/MR scans for diagnostic acquisitions. Finally, avenues for future investigation are discussed, with a focus on improvements that could improve PET image quality, and that are practical in the clinical environment. © 2017 American Association of Physicists in Medicine.

  5. Sportsmen’s Groin—Diagnostic Approach and Treatment With the Minimal Repair Technique

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-01-01

    Context: Sportsmen’s groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. Methods: The authors developed an innovative open suture repair—the Minimal Repair technique—to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. Results: The following advantages of the Minimal Repair technique were found: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). Conclusion: The Minimal Repair technique is an effective and safe way to treat sportsmen’s groin. PMID:23015941

  6. Diagnostics

    International Nuclear Information System (INIS)

    Borer, J.; Jung, R.

    1984-01-01

    All the non interacting monitors used for the p-anti p instrumentation can be related to the use of the wall image current as induced by relativistic charged particle bunches circulating in a metallic pipe or vacuum chamber. The monitors are then classified by their type of beam coupling impedance. This allows a more generalized approach of the design of the so-called pickups. (orig./HSI)

  7. Pancreatic Cysts: Current Concepts of Pathogenesis, Diagnosis and Diagnostic and Treatment Approach

    Directory of Open Access Journals (Sweden)

    V.М. Ratchik

    2014-09-01

    Full Text Available The relevance of pancreatic cyst treatment is determined by the increase in the incidence of pancreatitis, a considerable number of complications and high mortality rate. In recent decades, there has been steady growth of destructive forms of pancreatitis, respectively the number of pancreatic cysts increases. Pancreatic cysts in 18–68 % of cases cause various complications (suppuration, perforation, bleeding, internal and external fistulas, malignant transformation that define high mortality — 9.2–53 %. The nature and extent of surgery depend on the etiology, the presence or absence of the cyst connection with ductal system, the presence of complications. Surgical treatment for pancreatic cysts remains the method of choice. Minimally invasive surgical procedures became widely used. High prevalence of cystic lesions of the pancreas, the difficulty of choosing the optimal method of treatment require the creation of a rational, convenient for clinical practice diagnostic and therapeutic algorithm. Dissatisfaction with the results of treatment and a large number of complications lead to the search for a new, so called gold standard for treatment of patients and determine the real place of minimally invasive and open surgical techniques.

  8. Current knowledge and importance of dGEMRIC techniques in diagnosis of hip joint diseases

    Energy Technology Data Exchange (ETDEWEB)

    Zilkens, Christoph; Krauspe, Ruediger; Bittersohl, Bernd [University of Duesseldorf, Medical Faculty, Department of Orthopedic Surgery, Duesseldorf (Germany); Tiderius, Carl Johann [Lund University Hospital, Department of Orthopedic Surgery, Lund (Sweden)

    2015-08-15

    Accurate assessment of early hip joint cartilage alterations may help optimize patient selection and follow-up of hip joint preservation surgery. Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) is sensitive to the glycosaminoglycan content in cartilage that is lost early in the development of osteoarthritis (OA). Hence, the dGEMRIC technique holds promise for the development of new diagnostic and therapeutic procedures. However, because of the location of the hip joint deep within the body and due to the fairly thin cartilage layers that require high spatial resolution, the diagnosis of early hip joint cartilage alterations may be problematic. The purpose of this review is to outline the current status of dGEMRIC in the assessment of hip joint cartilage. A literature search was performed with PubMed, using the terms ''cartilage, osteoarthritis, hip joint, MRI, and dGEMRIC'', considering all levels of studies. This review revealed that dGEMRIC can be reliably used in the evaluation of early stage cartilage pathology in various hip joint disorders. Modifications in the technique, such as the operation of three-dimensional imaging and dGEMRIC after intra-articular contrast medium administration, have expanded the range of application. Notably, the studies differ considerably in patient selection and technical prerequisites. Furthermore, there is a need for multicenter prospective studies with the required technical conditions in place to establish outcome based dGEMRIC data to obtain, in conjunction with clinical data, reliable threshold values for normal and abnormal cartilage, and for hips that may benefit from conservative or surgical treatment. (orig.)

  9. Current knowledge and importance of dGEMRIC techniques in diagnosis of hip joint diseases

    International Nuclear Information System (INIS)

    Zilkens, Christoph; Krauspe, Ruediger; Bittersohl, Bernd; Tiderius, Carl Johann

    2015-01-01

    Accurate assessment of early hip joint cartilage alterations may help optimize patient selection and follow-up of hip joint preservation surgery. Delayed gadolinium-enhanced magnetic resonance imaging of cartilage (dGEMRIC) is sensitive to the glycosaminoglycan content in cartilage that is lost early in the development of osteoarthritis (OA). Hence, the dGEMRIC technique holds promise for the development of new diagnostic and therapeutic procedures. However, because of the location of the hip joint deep within the body and due to the fairly thin cartilage layers that require high spatial resolution, the diagnosis of early hip joint cartilage alterations may be problematic. The purpose of this review is to outline the current status of dGEMRIC in the assessment of hip joint cartilage. A literature search was performed with PubMed, using the terms ''cartilage, osteoarthritis, hip joint, MRI, and dGEMRIC'', considering all levels of studies. This review revealed that dGEMRIC can be reliably used in the evaluation of early stage cartilage pathology in various hip joint disorders. Modifications in the technique, such as the operation of three-dimensional imaging and dGEMRIC after intra-articular contrast medium administration, have expanded the range of application. Notably, the studies differ considerably in patient selection and technical prerequisites. Furthermore, there is a need for multicenter prospective studies with the required technical conditions in place to establish outcome based dGEMRIC data to obtain, in conjunction with clinical data, reliable threshold values for normal and abnormal cartilage, and for hips that may benefit from conservative or surgical treatment. (orig.)

  10. Schistosomiasis in the Amazon region: is the current diagnostic strategy still appropriate?

    Directory of Open Access Journals (Sweden)

    Sergei Rodrigo Magalhães de Sousa

    Full Text Available Abstract INTRODUCTION: This study analyzed the performance of the Kato Katz technique in detecting intestinal schistosomiasis in the State of Pará. METHODS: Of three stool samples provided by each of 380 participants, a total of 16 Kato Katz slides were examined to define the reference value (RV of positives for comparisons. RESULTS: The RV revealed 37 (9.7% infected participants in contrast to 10 (2.6% according to a single slide. CONCLUSIONS: This significant underestimation of the infection rate gives reason to discuss if the current classification of prevalence levels reflects the real situation, principally in low transmission areas, like the Amazon region.

  11. Development and applications of laser spectroscopic techniques related to combustion diagnostics

    International Nuclear Information System (INIS)

    Alden, Marcus

    2006-01-01

    Thanks to features as non-intrusiveness combined with high spatial and temporal resolution, various laser diagnostic techniques have during the last decades become of utmost importance for characterization of combustion related phenomena. In the following presentation some further development of the techniques will be highlighted aiming at a) surface temperatures using Thermographic Phosphors, TP, b) species specific, spatially and temporally resolved detection of species absorbing in the IR spectral region using polarization spectroscopy and Laser-induced fluorescence, and finally c) high speed visualization using a special designed laser system in combination with a framing camera. In terms of surface thermometry, Thermographic Phosphors have been used for many years for temperature measurements on solid surfaces. We have during the last years further developed and applied this technique for temperature measurements on burning surfaces and on materials going through phase shifts, e.g. pyrolysis and droplets. The basic principle behind this technique is to apply micron size particles to the surface of interest. By exciting the TP with a short pulse UV laser (ns), the phosphorescence will exhibit a behaviour where the spectral emission as well as the temporal decay are dependent on the temperature. It is thus possible to measure the temperature both in one and two dimensions. The presentation will include basic description of the technique as well as various applications, e.g in fire science, IC engines and gasturbines. Several of the species of interest for combustion/flow diagnostics exhibit a molecular structure which inhibits the use of conventional laser-induced fluorescence for spatially and spectrally resolved measurements. We have during the last years investigated the use of excitation and detection in the infrared region of the spectrum. Here, it is possible to detect both carbonmono/dioxide, water as well as species specific hydrocarbons. The techniques

  12. Effects of Different Compression Techniques on Diagnostic Accuracies of Breast Masses on Digitized Mammograms

    International Nuclear Information System (INIS)

    Zhigang Liang; Xiangying Du; Jiabin Liu; Yanhui Yang; Dongdong Rong; Xinyu Y ao; Kuncheng Li

    2008-01-01

    Background: The JPEG 2000 compression technique has recently been introduced into the medical imaging field. It is critical to understand the effects of this technique on the detection of breast masses on digitized images by human observers. Purpose: To evaluate whether lossless and lossy techniques affect the diagnostic results of malignant and benign breast masses on digitized mammograms. Material and Methods: A total of 90 screen-film mammograms including craniocaudal and lateral views obtained from 45 patients were selected by two non-observing radiologists. Of these, 22 cases were benign lesions and 23 cases were malignant. The mammographic films were digitized by a laser film digitizer, and compressed to three levels (lossless and lossy 20:1 and 40:1) using the JPEG 2000 wavelet-based image compression algorithm. Four radiologists with 10-12 years' experience in mammography interpreted the original and compressed images. The time interval was 3 weeks for each reading session. A five-point malignancy scale was used, with a score of 1 corresponding to definitely not a malignant mass, a score of 2 referring to not a malignant mass, a score of 3 meaning possibly a malignant mass, a score of 4 being probably a malignant mass, and a score of 5 interpreted as definitely a malignant mass. The radiologists' performance was evaluated using receiver operating characteristic analysis. Results: The average Az values for all radiologists decreased from 0.8933 for the original uncompressed images to 0.8299 for the images compressed at 40:1. This difference was not statistically significant. The detection accuracy of the original images was better than that of the compressed images, and the Az values decreased with increasing compression ratio. Conclusion: Digitized mammograms compressed at 40:1 could be used to substitute original images in the diagnosis of breast cancer

  13. Current and future delivery of diagnostic electron microscopy in the UK: results of a national survey.

    Science.gov (United States)

    de Haro, Tracey; Furness, Peter

    2012-04-01

    Electron microscopy (EM) remains essential to delivering several specialist areas of diagnosis, especially the interpretation of native renal biopsies. However, there is anecdotal evidence of EM units struggling to survive, for a variety of reasons. The authors sought to obtain objective evidence of the extent and the causes of this problem. An online survey was undertaken of Fellows of the Royal College of Pathologists who use EM in diagnosis. A significant number of EM units anticipate having to close and hence outsource their EM work in the coming years. Yet most existing units are working to full capacity and would be unable to take on the substantial amounts of extra work implied by other units outsourcing their needs. Equipment and staffing are identified by most EM units as the major barriers to growth and are also the main reasons cited for units facing potential closure. In the current financial climate it seems unlikely that units will be willing to make the large investment in equipment and staff needed to take on extra work, unless they can be reasonably confident of an acceptable financial return as a result of increased external referral rates. The case is thus made for a degree of national coordination of the future provision of this specialist service, possibly through the National Commissioning Group or the new National Commissioning Board. Without this, the future of diagnostic EM services in the UK is uncertain. Its failure would pose a threat to good patient care.

  14. Optical emission spectroscopy diagnostics of an atmospheric pressure direct current microplasma jet

    Energy Technology Data Exchange (ETDEWEB)

    Sismanoglu, B.N., E-mail: bogos@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil); Amorim, J., E-mail: jayr.amorim@bioetanol.org.b [Centro de Ciencia e Tecnologia do Bioetanol - CTBE, Caixa Postal 6170, 13083-970 Campinas, Sao Paulo (Brazil); Souza-Correa, J.A., E-mail: jorge.correa@bioetanol.org.b [Centro de Ciencia e Tecnologia do Bioetanol - CTBE, Caixa Postal 6170, 13083-970 Campinas, Sao Paulo (Brazil); Oliveira, C., E-mail: carlosf@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil); Gomes, M.P., E-mail: gomesmp@ita.b [Departamento de Fisica, Instituto Tecnologico de Aeronautica, Comando-Geral de Tecnologia Aeroespacial, Pca Marechal Eduardo Gomes 50, 12 228-900, Sao Jose dos Campos, SP (Brazil)

    2009-11-15

    This paper is about the use of optical emission spectroscopy as a diagnostic tool to determine the gas discharge parameters of a direct current (98% Ar-2% H{sub 2}) non-thermal microplasma jet, operated at atmospheric pressure. The electrical and optical behaviors were studied to characterize this glow discharge. The microplasma jet was investigated in the normal and abnormal glow regimes, for current ranging from 10 to 130 mA, at approx 220 V of applied voltage for copper cathode. OH (A {sup 2}SIGMA{sup +}, nu = 0 -> X {sup 2}PI, nu' = 0) rotational bands at 306.357 nm and also the 603.213 nm Ar I line, which is sensitive to van der Waals broadening, were used to determine the gas temperature, which ranges from 550 to 800 K. The electron number densities, ranging from 6.0 x 10{sup 14} to 1.4 x 10{sup 15} cm{sup -3}, were determined through a careful analysis of the main broadening mechanisms of the H{sub beta} line. From both 603.213 nm and 565.070 nm Ar I line broadenings, it was possible to obtain simultaneously electron number density and temperature (approx 8000 K). Excitation temperatures were also measured from two methods: from two Cu I lines and from Boltzmann-plot of 4p-4s and 5p-4s Ar I transitions. By employing H{sub alpha} line, the hydrogen atoms' H temperature was estimated (approx 18,000 K) and found to be surprisingly hotter than the excitation temperature.

  15. A general purpose diagnostic technique for marine diesel engines - Application on the main propulsion and auxiliary diesel units of a marine vessel

    International Nuclear Information System (INIS)

    Lamaris, V.T.; Hountalas, D.T.

    2010-01-01

    Diesel engines are widely used in marine applications (i.e. propulsion and auxiliaries) except from a few cases where gas or steam turbines are used. This is the result of their high efficiency, power concentration and reliability compared to other compatible or alternative power sources. The proper and efficient operation of the engines (main engine and diesel generator units) in marine applications is critical, and therefore techniques or systems that determine engine current condition and detect potential faults are extremely important. Furthermore, it is advantageous when such techniques can be applied on different engine configurations and provide reliable results, because on a vessel usually exist diesel engines of different type, i.e. the main propulsion unit is a large low-speed two-stroke diesel engine while the diesel generators are four-stroke medium or high speed engines. In the present work is described and evaluated for the first time the application of an improved diagnostic technique, developed by the authors, on both the main engine and the auxiliary units of a commercial marine vessel. The diagnostic technique is based on a thermodynamic simulation model. The simulation model embedded in the technique has been modified, namely an existing two-zone model is replaced by a multi-zone one. With this modification it is avoided model constant tuning with the operating conditions. This is extremely important for the diagnostic philosophy of the proposed technique. Using data from engine shop tests, the simulation model is calibrated (i.e. model constants are determined) and the engine reference condition is obtained. The simulation model is then used to estimate the current engine condition, using field measurements (i.e. cylinder pressure measurements, periphery data, etc.). From the results it is revealed that the diagnosis method provides detailed information for the operating condition of both engines and the values of parameters that cannot be

  16. The role of choline (Cho) in the diagnostics and differentiation of brain tumours with HMRS technique

    International Nuclear Information System (INIS)

    Sobiecka, B.; Urbanik, A.

    2009-01-01

    Background: The aim of the research was a comprehensive analysis of Cho concentration and Cho/Cr, NAA/Cho, NAA/Cho+Cr ratios for the purposes of the diagnostics and differentiation of brain tumours (the type of the pathological lesion in patients with brain tumours) with the use of HMRS technique. Material/Methods: The HMRS examinations were performed with the use of the MRI Signa Excite 1.5 T system, in PRESS technique (TR = 1500 ms, TE = 35 ms) and involved 100 patients with brain tumours (age range: 18 to 81 yrs, mean age 50.61). Spectra were taken from three different locations: tumour centre, the tumour edge and contralateral unchanged cerebral tissue. All patients underwent surgery followed by histopathological analysis, on the basis of which two groups were separated (benign tumours, malignant tumours - 50 cases each). Additionally, 30 healthy volunteers in the age of 20 to 79 years (mean age 40.8) were examined. Results: The comparison of the examined patients with the control group revealed significantly higher Cho concentrations in patients with brain tumours. The analysis of Cho concentration was also performed with consideration of the age factor (under and over 60 years of age). Significantly lower mean Cho concentrations were discovered in a group of patients under 60 years of age. The analysis of Cho concentrations and Cho/Cr ratios reveled statistical significance for two factors: voxel location factor and the type of the pathological lesion. The average of Cho concentration and Cho/Cr ratios were higher in the group of patients with malignant tumours. The highest Cho concentrations and Cho/Cr ratios were observed in the tumour centre. The relative NAA/Cho and NAA/Cho+Cr ratios were statistically significant when taking into consideration the voxel location factor only. The results received from contralateral normal cerebral tissue (the internal model) were compared with control group (the external model). Mean values of Cho concentration were

  17. Epidemiology of intestinal parasitosis in Italy between 2005 and 2008: diagnostic techniques and methodologies

    Directory of Open Access Journals (Sweden)

    Daniele Crotti

    2013-04-01

    Full Text Available Aim of the study was to keep a real and actual photo relating to 2005-2008 regarding to diagnostic techniques and methodologies for intestinal parasites; so it would be possible to know specific epidemiology and suggest more rational and efficacious guide-lines. All members of AMCLI were involved in the proposal of a retrospective study regarding bowel parasites, helminths and protozoa.To engaged laboratories we asked how O&P was performed, if a specifical research for E. vermicularis and S. stercoralis was performed, if for the identification of D. fragilis, Entamoeba histolytica/dispar and Cryptosporidum spp were performed recommended specific permanent stains. 23 laboratories gave assent; but for an inferior number was possible to use the data for analysis and evaluation. Relating O&P only some laboratories performed permanent stains: Giemsa for D. fragilis, antigen and/or Trichrome stain for E. histolytica/dispar, antigen and/or acid fast stain for Cryptosporidium spp.Not all laboratories research specifically S. stercoralis. So the epidemiology is differentiated and related more to adequate or not adequate techniques than cohorts of examined populations. The overall positivity for parasites ranged from 0% to18.7%,for protozoa (pathogens or not were from 0% to 14.7%; for nematodes from 0% to 3.7%; for cestodes from 0% to 1.0%; for trematodes from 0% to 1.0%.Among helminths, E. vermicularis, followed by S. stercoralis, also in O&P, is the most frequent.The specific research of S. stercoralis gave a positivity from 0% to 33.3%; the cellophane tape test was positive for E. vermicularis from 0% fo 21.9% of cases.Among pathogen protozoa, D. fragilis, when permanent stain were applied, prevailed from 0% to 16.6%; G. duodenalis from 0.8% to 4.3%; E. histolytica/dispar, using a permanent stain or research of antigen, was identified from 0% to 20.6%. Coccidia were very rare, with Cryptosporidium spp observed from 0% to 5.2%. These are our conclusions

  18. About increasing informativity of diagnostic system of asynchronous electric motor by extracting additional information from values of consumed current parameter

    Science.gov (United States)

    Zhukovskiy, Y.; Korolev, N.; Koteleva, N.

    2018-05-01

    This article is devoted to expanding the possibilities of assessing the technical state of the current consumption of asynchronous electric drives, as well as increasing the information capacity of diagnostic methods, in conditions of limited access to equipment and incompleteness of information. The method of spectral analysis of the electric drive current can be supplemented by an analysis of the components of the current of the Park's vector. The research of the hodograph evolution in the moment of appearance and development of defects was carried out using the example of current asymmetry in the phases of an induction motor. The result of the study is the new diagnostic parameters of the asynchronous electric drive. During the research, it was proved that the proposed diagnostic parameters allow determining the type and level of the defect. At the same time, there is no need to stop the equipment and taky it out of service for repair. Modern digital control and monitoring systems can use the proposed parameters based on the stator current of an electrical machine to improve the accuracy and reliability of obtaining diagnostic patterns and predicting their changes in order to improve the equipment maintenance systems. This approach can also be used in systems and objects where there are significant parasitic vibrations and unsteady loads. The extraction of useful information can be carried out in electric drive systems in the structure of which there is a power electric converter.

  19. Review of current status of high flux heat transfer techniques. Volume I. Text + Appendix A

    International Nuclear Information System (INIS)

    Bauer, W.H.; Gordon, H.S.; Lackner, H.; Mettling, J.R.; Miller, J.E.

    1980-09-01

    The scope of this work comprised two tasks. The first was to review high heat flux technology with consideration given to heat transfer panel configuration, diagnostics techniques and coolant supply. The second task was to prepare a report describing the findings of the review, to recommend the technology offering the least uncertainty for scale-up for the MFTF-B requirement and to recommend any new or perceived requirements for R and D effort

  20. Review of current status of high flux heat transfer techniques. Volume I. Text + Appendix A

    Energy Technology Data Exchange (ETDEWEB)

    Bauer, W.H.; Gordon, H.S.; Lackner, H.; Mettling, J.R.; Miller, J.E.

    1980-09-01

    The scope of this work comprised two tasks. The first was to review high heat flux technology with consideration given to heat transfer panel configuration, diagnostics techniques and coolant supply. The second task was to prepare a report describing the findings of the review, to recommend the technology offering the least uncertainty for scale-up for the MFTF-B requirement and to recommend any new or perceived requirements for R and D effort.

  1. Diagnostic value of the fluoroscopic triggering 3D LAVA technique for primary liver cancer.

    Science.gov (United States)

    Shen, Xiao-Yong; Chai, Chun-Hua; Xiao, Wen-Bo; Wang, Qi-Dong

    2010-04-01

    Primary liver cancer (PLC) is one of the common malignant tumors. Liver acquisition with acceleration volume acquisition (LAVA), which allows simultaneous dynamic enhancement of the hepatic parenchyma and vasculature imaging, is of great help in the diagnosis of PLC. This study aimed to evaluate application of the fluoroscopic triggering 3D LAVA technique in the imaging of PLC and liver vasculature. The clinical data and imaging findings of 38 adults with PLC (22 men and 16 women; average age 52 years), pathologically confirmed by surgical resection or biopsy, were collected and analyzed. All magnetic resonance images were obtained with a 1.5-T system (General Electrics Medical Systems) with an eight-element body array coil and application of the fluoroscopic triggering 3D LAVA technique. Overall image quality was assessed on a 5-point scale by two experienced radiologists. All the nodules and blood vessel were recorded and compared. The diagnostic accuracy and feasibility of LAVA were evaluated. Thirty-eight patients gave high quality images of 72 nodules in the liver for diagnosis. The accuracy of LAVA was 97.2% (70/72), and the coincidence rate between the extent of tumor judged by dynamic enhancement and pathological examination was 87.5% (63/72). Displayed by the maximum intensity projection reconstruction, nearly all cases gave satisfactory images of branches III and IV of the hepatic artery. Furthermore, small early-stage enhancing hepatic lesions and the parallel portal vein were also well displayed. Sequence of LAVA provides good multi-phase dynamic enhancement scanning of hepatic lesions. Combined with conventional scanning technology, LAVA effectively and safely displays focal hepatic lesions and the relationship between tumor and normal tissues, especially blood vessels.

  2. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    Energy Technology Data Exchange (ETDEWEB)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W. [Chosun University, Gwangju (Korea, Republic of); Ahn, K. I. [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of)

    2010-06-15

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  3. Development of an Accident Diagnostic Scheme Using Artificial Intelligence Techniques (I)

    International Nuclear Information System (INIS)

    Na, M. G.; Lee, S. H.; Kim, D. S.; No, Y. G.; Lee, S. W.; Ahn, K. I.

    2010-06-01

    As a means to effectively manage the severe nuclear accidents, it is important to identify and diagnose the accident initiating events during an initial short time interval after the accidents by observing the major controlling parameters. Main objective of this study is to develop the diagnostic approach for the accurate prediction of accident initiating events using artificial intelligence techniques. For this, first, a variety of artificial intelligence techniques such as Finn, Gmbh, and Sm were examined through this study. Among them, Sc and Gmbh model were assessed as a useful approach to predict the break location and the break size of Local. In order to verify the proposed algorithm, the 111 accident simulation data (based on Map) were applied to train the Sc and Gmbh models, and the test data was used to independently verify whether or not the SVC and GMDH models work well. The analysis of the maximum errors and RMS errors, and the performance of the GMDH according to the existence of measurement errors and SIS actuation showed that the proposed SVC and GMDH models can accurately classify the break locations and accurately predict the break size. As the time-integrated signals were used for inputs into the GMDH model within a period of 60 second after a reactor scram, the actuation of the safety systems such as safety injection system (SIS), auxiliary feed water system, and containment spray system, were not considered in this study. It is because the initial 60 second time-integrated signals were used and the safety systems usually start to actuate after a more than 60 second time delay after the reactor scram

  4. Comparative value of diagnostic imaging techniques in a cat with exophthalmos

    International Nuclear Information System (INIS)

    Ramsey, D.T.; Gerding, P.A. Jr.; Losonsky, J.M.; Kuriashkin, I.V.; Clarkson, R.D.

    1994-01-01

    A mass that appeared to originate from the frontal bone and extended into retrobulbar tissues of the light orbit was imaged in a cat using ultrasound, skull radiographs, computed tomography, and magnetic resonance imaging. The cat was presented with ventrolateral strabismus, exophthalmos, and elevated nictitans membrane of the tight eye. The mass was not delineated entirely after orbital echography and survey radiography of the skull was performed. Cytologic examination of fine-needle aspirate of the mass was suggestive of a neoplastic disease. Results of computed tomography indicated lysis of the calvarium but did not delineate borders of the mass in the calvarium. Magnetic resonance imaging was then used to confirm borders of the neoplasm. Magnetic resonance imaging was the only imaging technique that delineated the entire border of the neoplasm, including in the calvarium, when compared to postmortem evaluation. Results of orbital echography, skull radiographs, or computed tomography, when used as the only diagnostic imaging modality, must be interpreted with caution when evaluating borders of retrobulbar neoplasia prior to surgical planning

  5. Nonculture molecular techniques for diagnosis of bacterial disease in animals: a diagnostic laboratory perspective.

    Science.gov (United States)

    Cai, H Y; Caswell, J L; Prescott, J F

    2014-03-01

    The past decade has seen remarkable technical advances in infectious disease diagnosis, and the pace of innovation is likely to continue. Many of these techniques are well suited to pathogen identification directly from pathologic or clinical samples, which is the focus of this review. Polymerase chain reaction (PCR) and gene sequencing are now routinely performed on frozen or fixed tissues for diagnosis of bacterial infections of animals. These assays are most useful for pathogens that are difficult to culture or identify phenotypically, when propagation poses a biosafety hazard, or when suitable fresh tissue is not available. Multiplex PCR assays, DNA microarrays, in situ hybridization, massive parallel DNA sequencing, microbiome profiling, molecular typing of pathogens, identification of antimicrobial resistance genes, and mass spectrometry are additional emerging technologies for the diagnosis of bacterial infections from pathologic and clinical samples in animals. These technical advances come, however, with 2 caveats. First, in the age of molecular diagnosis, quality control has become more important than ever to identify and control for the presence of inhibitors, cross-contamination, inadequate templates from diagnostic specimens, and other causes of erroneous microbial identifications. Second, the attraction of these technologic advances can obscure the reality that medical diagnoses cannot be made on the basis of molecular testing alone but instead through integrated consideration of clinical, pathologic, and laboratory findings. Proper validation of the method is required. It is critical that veterinary diagnosticians understand not only the value but also the limitations of these technical advances for routine diagnosis of infectious disease.

  6. Spiral CT during pharmacoangiography with angiotensin II in patients with pancreatic disease. Technique and diagnostic efficacy

    Energy Technology Data Exchange (ETDEWEB)

    Kuroda, C.; Mihara, N.; Hosomi, N.; Inoue, E.; Fujita, M. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Diagnostic Radiology; Ohigashi, H.; Ishikawa, O. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Surgery; Nakaizumi, A. [Osaka Medical Center for Cancer and Cardiovascular Deseases (Japan). Dept. of Internal Medicine; Ishiguro, S. [Osaka Medical Center for Cancer and Cardiovascular Diseases (Japan). Dept. of Pathology

    1998-03-01

    Purpose: To compare the diagnostic efficacy of pancreatic pharmacoangiographic CT using angiotensin II with conventional angiographic CT. Material and Methods: Eighteen patients with space-occupying pancreatic disease were examined in this study. Pharmacoangiographic CT was performed with a 1-3-{mu}/6-ml solution of angiotensin II injected through a catheter into the celiac artery during spiral CT. Results: In 17 of the 18 (94%) patients, the area of pancreatic parenchymal enhancement was the same or larger at pharmacoangiographic CT than at conventional angiographic CT. The attenuation value of the pancreatic parenchyma was significantly increased at pharmacoangiographic CT (p=0.0010). Although the attenuation value of tumors was also increased on images obtained after the injection of angiotensin II, the tumor-to-pancreas contrast was significantly greater at pharmacoangiographic CT (p=0.0479). The mean differences in attenuation between tumor and pancreas at angiographic CT with and without angiotensin II were respectively 182 HU and 115 HU. Conclusion: Pharmacoangiographic CT with angiotensin II proved superior to conventional angiographic CT in the diagnosis of pancreatic disease. We therefore recommend it as a supplementary technique at the angiographic examination of patients with suspected pancreatic tumor. (orig.).

  7. Development of long-pulse heating & current drive actuators & operational techniques compatible with a high-Z divertor & first wall

    Energy Technology Data Exchange (ETDEWEB)

    Tynan, George [Univ. of California, San Diego, CA (United States)

    2018-01-09

    This was a collaboration between UCSD and MIT to study the effective application of ion-cyclotron heating (ICRH) on the EAST tokamak, located in China. The original goal was for UCSD to develop a diagnostic that would allow measurement of the steady state, or DC, convection pattern that develops on magnetic field lines that attach or connect to the ICRH antenna. This diagnostic would then be used to develop techniques and approaches that minimize or even eliminate such DC convection during application of strong ICRH heating. This was thought to then indicate reduction or elimination of parasitic losses of heating power, and thus be an indicator of effective RF heating. The original plan to use high speed digital gas-puff imaging (GPI) of the antenna-edge plasma region in EAST was ultimately unsuccessful due to limitations in machine and camera operations. We then decided to attempt the same experiment on the ALCATOR C-MOD tokamak at MIT which had a similar instrument already installed. This effort was ultimately successful, and demonstrated that the underlying idea of using GPI as a diagnostic for ICRH antenna physics would, in fact, work. The two-dimensional velocity fields of the turbulent structures, which are advected by RF-induced E x B flows, are obtained via the time-delay estimation (TDE) techniques. Both the magnitude and radial extension of the radial electric field E-r were observed to increase with the toroidal magnetic field strength B and the ICRF power. The TDE estimations of RF-induced plasma potentials are consistent with previous results based on the probe measurements of poloidal phase velocity. The results suggest that effective ICRH heating with reduced impurity production is possible when the antenna/box system is designed so as to reduce the RF-induced image currents that flow in the grounded conducting antenna frame elements that surround the RF antenna current straps.

  8. Practical X-ray diagnostics orthopedics and trauma surgery. Indication, adjustment technique and radiation protection

    International Nuclear Information System (INIS)

    Flechtenmacher, Johannes; Sabo, Desiderius

    2014-01-01

    The book on X-ray diagnostics in orthopedics and trauma surgery includes the following chapters: 1. Introduction: radiation protection, equipment technology radiological diagnostics of skeleton carcinomas, specific aspects of trauma surgery, special aspects of skeleton radiology for children. 2. X-ray diagnostics of different anatomical regions: ankle joint, knee, hips and pelvis, hand and wrist joint, elbow, shoulder, spinal cord. 3. Appendix: radiation protection according to the X-ray regulations.

  9. Current approach to the diagnosis of IgG4-related disease - Combination of comprehensive diagnostic and organ-specific criteria.

    Science.gov (United States)

    Umehara, Hisanori; Okazaki, Kazuichi; Nakamura, Takuji; Satoh-Nakamura, Tomomi; Nakajima, Akio; Kawano, Mitsuhiro; Mimori, Tsuneyo; Chiba, Tsutomu

    2017-05-01

    IgG4-related disease (IgG4-RD) is a fascinating clinical entity proposed by Japanese investigators, and includes a wide variety of diseases, formerly diagnosed as Mikulicz's disease (MD), autoimmune pancreatitis (AIP), interstitial nephritis, prostatitis, retroperitoneal fibrosis, etc. Although all clinicians in every field of medicine may encounter this new disease, a unifying diagnostic criterion has not been established. In 2011, the Japanese IgG4 team, organized by the Ministry of Health, Labor and Welfare (MHLW) of Japan, published comprehensive diagnostic criteria for IgG4-RD. Several problems with these criteria have arisen in clinical practice, however, including the difficulty obtaining biopsy samples from some patients, and the sensitivity and the specificity of techniques used to measure serum IgG4 concentrations. Although serum IgG4 concentration is an important clinical marker for IgG4-RD, its diagnostic utility in differentiating IgG4-RD from other diseases, called IgG4-RD mimickers, remains unclear. This review describes the current optimal approach for the diagnosis of IgG4-RD, based on both comprehensive and organ-specific diagnostic criteria, in patients with diseases such as IgG4-related pancreatitis (AIP), sclerosing cholangitis, and renal, lung and orbital diseases.

  10. Diagnostic Development on NSTX

    International Nuclear Information System (INIS)

    A.L. Roquemore; D. Johnson; R. Kaita; et al

    1999-01-01

    Diagnostics are described which are currently installed or under active development for the newly commissioned NSTX device. The low aspect ratio (R/a less than or equal to 1.3) and low toroidal field (0.1-0.3T) used in this device dictate adaptations in many standard diagnostic techniques. Technical summaries of each diagnostic are given, and adaptations, where significant, are highlighted

  11. Towards non-invasive diagnostic techniques for early detection of acute renal transplant rejection: A review

    Directory of Open Access Journals (Sweden)

    Elizabeth Hollis

    2017-03-01

    Full Text Available The kidney is a very important complicated filtering organ of the body. When the kidney reaches stage 5 chronic kidney disease, end stage renal failure, the preeminent therapy is renal transplantation. Although it is the best form of treatment, lack of kidney donors is still challenging. Therefore, all efforts should be employed to prolong the survival rate of the transplanted kidney. However, graft dysfunction (e.g., acute rejection is one of the serious barriers to long term kidney transplant survival. Currently, graft dysfunction’s gold standard of diagnosis is renal biopsy. Although renal biopsy is helpful, it is not preferred due to its invasive nature, high morbidity rates, and expensiveness. Therefore, noninvasive imaging techniques have become the subject of extensive research and interest, giving a strong promise to replace, or at least to decrease, biopsy usage in diagnosing graft dysfunction. This survey will discuss not only the current diagnosis and treatment of graft dysfunction but also the state-of-the-art imaging techniques in detecting acute renal transplant rejection.

  12. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    Energy Technology Data Exchange (ETDEWEB)

    Axelsson, B.; Hansson, I.B. [Department of Hospital Physics, Karolinska Hospital, Stockholm (Sweden); Boden, K.; Witt, H.H. [Department of Diagnostic Radiology, Karolinska Hospital, Stockholm (Sweden); Fransson, S.G. [Department of Thoracic Radiology, University Hospital, Linkoeping (Sweden); Persliden, J. [Department of Radiation Physics, University Hospital, Linkoeping (Sweden)

    2000-08-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm{sup 2}) for the fully digital technique compared to the others (analogue 6.8 Gycm{sup 2}, analogue+digital 3.6 Gycm{sup 2}). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  13. A comparison of analogue and digital techniques in upper gastrointestinal examinations: absorbed dose and diagnostic quality of the images

    International Nuclear Information System (INIS)

    Axelsson, B.; Hansson, I.B.; Boden, K.; Witt, H.H.; Fransson, S.G.; Persliden, J.

    2000-01-01

    This study was performed to investigate whether patient exposure and diagnostic quality of the image is significantly influenced by the introduction of digital image acquisition techniques. Evaluation was performed for three different techniques (analogue, analogue fluoro+digital radiography, digital) in examination of the upper gastrointestinal tract. The evaluation was done from data acquired in three different departments. Patient exposure was recorded as KERMA-area product (KAP) and the individual patient readings were normalised to a standard size patient. Image quality was assessed using visual grading with a reference image. The recorded KAP values were significantly higher (22.3 Gycm 2 ) for the fully digital technique compared to the others (analogue 6.8 Gycm 2 , analogue+digital 3.6 Gycm 2 ). This was due mostly to an increased number of exposures. The diagnostic quality of the image was, however, also regarded to be slightly lower for the technique giving the lowest patient dose with the smallest number of exposures (analogue+digital). The digital examination technique, as used in this study, thus resulted in significantly higher patient dose without any significant gain in diagnostic quality of the image. (orig.)

  14. Use of sting-response techniques for simulate diagnostics in human esophagus

    International Nuclear Information System (INIS)

    Rodriguez, I.; Gonzalez, Y.; Valdes, L.; Alfonso, J.A.; Estevez, E.

    2003-01-01

    In this work a study of simulation of the gamma graphic studies that are carried out in human esophagus in the Dept. of Nuclear Medicine of the 'Celestino Hernandez Robau Hospital of Santa Clara is presented. For the investigation tubular reactors were used and sting-response techniques with radioactive tracer of Technetium 99 metastable to a concentration of 1 mCi and several flows were applied. The distribution curves of residences times were obtained, those that respond to an equation of the type: Y = A + B exp (- exp((x-C)/D)) - ((x-C/D)+1). They were also carried out, optimizations studies of the doses of the radioactive to give to the patients from 1 mCi (that is the one used in studies) up to 0,5 mCi, and the influences on the obtained distributions of residence time were analyzed. It was confirmed the possibility to lower the doses with clear information of the signal. It was also carried out a simulation of the attenuation of the radiations that takes place in the patients by the interposition of tissues among the analyzed organ, and the detection equipment. It was used paraffin for tissue simulation. It was found the almost independence of the intensity of the radiations with the thickness, for the assayed doses. Lastly it was found a complex mathematical model that responds to the diagnostic curves obtained in these studies, being correlated the coefficients of the pattern with the most important physical parameters of the system, giving it a practical and useful value, all time that the error among the values that this it predicts and the experimental ones do not surpass of 5%. (Author)

  15. Twin Anemia Polycythemia Sequence: Current Views on Pathogenesis, Diagnostic Criteria, Perinatal Management, and Outcome.

    Science.gov (United States)

    Tollenaar, Lisanne S A; Slaghekke, Femke; Middeldorp, Johanna M; Klumper, Frans J; Haak, Monique C; Oepkes, Dick; Lopriore, Enrico

    2016-06-01

    Monochorionic twins share a single placenta and are connected with each other through vascular anastomoses. Unbalanced inter-twin blood transfusion may lead to various complications, including twin-to-twin transfusion syndrome (TTTS) and twin anemia polycythemia sequence (TAPS). TAPS was first described less than a decade ago, and the pathogenesis of TAPS results from slow blood transfusion from donor to recipient through a few minuscule vascular anastomoses. This gradually leads to anemia in the donor and polycythemia in the recipient, in the absence of twin oligo-polyhydramnios sequence (TOPS). TAPS may occur spontaneously in 3-5% of monochorionic twins or after laser surgery for TTTS. The prevalence of post-laser TAPS varies from 2% to 16% of TTTS cases, depending on the rate of residual anastomoses. Pre-natal diagnosis of TAPS is currently based on discordant measurements of the middle cerebral artery peak systolic velocity (MCA-PSV; >1.5 multiples of the median [MoM] in donors and 8 g/dL), and at least one of the following: reticulocyte count ratio >1.7 or minuscule placental anastomoses. Management includes expectant management, and intra-uterine blood transfusion (IUT) with or without partial exchange transfusion (PET) or fetoscopic laser surgery. Post-laser TAPS can be prevented by using the Solomon laser surgery technique. Short-term neonatal outcome ranges from isolated inter-twin Hb differences to severe neonatal morbidity and neonatal death. Long-term neonatal outcome in post-laser TAPS is comparable with long-term outcome after treated TTTS. This review summarizes the current knowledge after 10 years of research on the pathogenesis, diagnosis, management, and outcome in TAPS.

  16. Transanal endoscopic microsurgery as technique surgical for the treatment of the rectal adenocarcinoma: history, evolution and current tendency

    International Nuclear Information System (INIS)

    Vega Padilla, Luis Carlos

    2013-01-01

    The modalities of local and minimally invasive treatment were described for early rectal adenocarcinomas. The most adequate diagnostic studies and interdisciplinary interactions involved were considered in the process and the therapeutic results, in comparison with the current radical treatments. The historical evolution of the different surgical techniques developed over time, and the anatomical and physiological concepts were reviewed. The epidemiological behavior of the disease was documented according to gender, age and most prevalent sites to direct the possible risk groups to suffer the disease. Risk factors that affect patients with colorectal cancer were identified and related to the environment, social habits and hereditary. The different genetic syndromes involved in colorectal cancer, its physiopathology and clinical manifestations and implications were examined with respect to colorectal cancer. Colorectal cancer was defined according to the updated classifications of the American Joint Cancer Committee, according to the depth, affectation of lymph nodes and metastasis to distant organs, in relation to its clinical stage. Current surgical techniques were named to treat early adenocarcinomas of inferior rectus. The different risk factors were analyzed to allow local resections of the early rectal tumors, from the histopalogical, radiological and clinical point of view. The traditional techniques of transanal and radical resection were compared against the transanal endoscopic microsurgery between different aspects such as technical difficulty, recurrence rate, morbidity and mortality, and economic cost [es

  17. Enhancing the capabilities of eddy current techniques for non-destructive evaluation of austenitic stainless steels

    International Nuclear Information System (INIS)

    Rao, B.P.C.; Thirunavukkarasu, S.; Sasi, B.; Jayakumar, T.; Baldev Raj

    2010-01-01

    Eddy current non-destructive evaluation (NDE) techniques find many applications during fabrication and in-service inspection of components made of stainless steel. In recent years, concurrent developments in electromagnetic field detection sensors such as giant magneto-resistive (GMR), giant-magneto impedance (GMI) and SQUIDs sensors, computers, microelectronics, and incorporating advanced signal and image processing techniques, have paved the way for enhancing the capabilities of existing eddy current (EC) techniques for examination of austenitic stainless steel (SS) plates, tubes and other geometries and several innovative methodologies have been developed. This paper highlights a few such applications in EC testing to austenitic stainless steel components used in fast reactors. (author)

  18. Effects of modulation techniques on the input current interharmonics of Adjustable Speed Drives

    DEFF Research Database (Denmark)

    Soltani, Hamid; Davari, Pooya; Zare, Firuz

    2018-01-01

    operation of the grid. This paper presents the effect of the symmetrical regularly sampled Space Vector Modulation (SVM) and Discontinuous Pulse Width Modulation-30olag (DPWM2) techniques, as the most popular modulation methods in the ASD applications, on the drive’s input current interharmonic magnitudes....... Further investigations are also devoted to the cases, where the Random Modulation (RM) technique is applied on the selected modulation strategies. The comparative results show that how different modulation techniques can influence the ASD’s input current interharmonics and consequently may...

  19. Proposal on ''standardized high current solid targets for cyclotron production of diagnostic and therapeutic radionuclides''

    International Nuclear Information System (INIS)

    Suparman, Ibon

    2000-01-01

    The Center for the Development of Radioisotopes and Radiopharmaceuticals - National Nuclear Energy Agency (P2RR-BATAN) has one Cyclotron type CS-30 with maximum 30 MeV proton energy. It is used since 1990 for 201 Tl production. The main use of 201 Tl in Indonesia is for diagnosis and assessment of myocardial ischaemia, especially diagnosis of coronary artery disease, viability of the heart muscle and forecasting the outcome for patients with coronary disease. The Cyclotron facility is supported with a solid target station, two hot cells and the chemical equipment for electroplating. The yield of 201 Tl production currently achieved around 40-50%. The irradiation technique and chemical separation should be improved. We are also very interested in the development of the production of 103 Pd via 103 Rh (p,n) 103 Pd reaction. The objective of this proposal will support the main program of the National Nuclear Energy Agency (BATAN) in enhancement of health care and in providing Cyclotron produced radiopharmaceuticals for hospitals

  20. Current diagnostics and treatment of the cubital tunnel syndrome in Austria

    Directory of Open Access Journals (Sweden)

    Harder, Kristina

    2016-01-01

    Full Text Available According to the vote of the Austrian Society for Surgery of the Hand (ÖGH an investigation to collect data on the current state of the treatment of cubital tunnel syndrome was initiated. Over one year a total of 875 patients with cubital tunnel syndrome were operated in Austria, this means an incidence of this nerve entrapment of 0.011%. Most of the operations were done by trauma surgeons (287; 33%. For diagnosis most of the centers rely on clinical symptoms, electroneurophysiology, and elbow X-ray. 40% of the institutions regard conservative therapy as useless and not indicated. If conservative treatment modalities are applied, physiotherapy (97%, non-steroidal anti-inflammatory medication (77%, and glucocorticoid injections (30% are primarily used. In case of simple nerve entrapment most of the surgeons (72% prefer simple nerve decompression. If there is additional pathology subcutaneous cubital nerve transposition is recommended (62%. Endoscopic techniques are only use by 3% of the surgeons. In the postoperative care, physiotherapy is favored in 51%, whereas 24% do not judge any postoperative care as beneficial.The three most often encountered complications were incomplete remission, scar contracture and hypertrophy, and postoperative bleeding.

  1. [Acoustic emission diagnostic techniques for high-field high current-density super inducting poles

    International Nuclear Information System (INIS)

    1990-01-01

    Acoustic emission technology was introduced in the late 1970's to monitor superconducting magnets. It has now been firmly established that acoustic signals in superconducting magnets are emitted principally by mechanical events such as conductor strain, conductor motion, frictional motion, and epoxy cracking. Despite earlier suggestions, flux motion, except during flux jumping, does not appear to be an important source of AE signals in superconducting magnets. Of these several potential sources of AE signals in superconducting magnets, mechanical disturbances have been identified to be most important in high-performance, ''adiabatic'' magnets such as the dipoles used in accelerators. These mechanical disturbances are transitory, each generating a packet of AE signals that can be located with sensors. Source identification and location has been achieved with a number of superconducting magnets. In this section, the basic principle for the operation of adiabatic magnets is discussed, followed by presentation of some of the important experimental results relevant to the question of premature quench obtained at MIT

  2. Uncertainty Management for Diagnostics and Prognostics of Batteries using Bayesian Techniques

    Data.gov (United States)

    National Aeronautics and Space Administration — Uncertainty management has always been the key hurdle faced by diagnostics and prognostics algorithms. A Bayesian treatment of this problem provides an elegant and...

  3. Diagnostic utility of selective nerve root blocks in the diagnosis of lumbosacral radicular pain: systematic review and update of current evidence.

    Science.gov (United States)

    Datta, Sukdeb; Manchikanti, Laxmaiah; Falco, Frank J E; Calodney, Aaron K; Atluri, Sairam; Benyamin, Ramsin M; Buenaventura, Ricardo M; Cohen, Steven P

    2013-04-01

      Lumbosacral selective nerve root blocks and/ or transforaminal epidural injections are used for diagnosis and treatment of different disorders causing low back and lower extremity pain. A clear consensus on the use of selective nerve root injections as a diagnostic tool does not currently exist. Additionally, the validity of this procedure as a diagnostic tool is not clear. To evaluate and update the accuracy of selective nerve root injections in diagnosing lumbar spinal disorders. A systematic review of selective nerve root blocks for the diagnosis of low back and lower extremity pain. Methodological quality assessment of included studies was performed using the Quality Appraisal of Reliability Studies (QAREL) checklist. Only diagnostic accuracy studies meeting at least 50% of the designated inclusion criteria were utilized for analysis. Studies scoring less than 50% are presented descriptively and analyzed critically. The level of evidence was classified as good, fair, or limited or poor based on the quality of evidence grading scale developed by the United States Preventive Services Task Force (USPSTF). Data sources included relevant literature identified through searches of PubMed and EMBASE from 1966 to September 2012, and manual searches of the bibliographies of known primary and review articles. In this review, we evaluated studies in which controlled local anesthetic blocks were performed using at least 50% pain relief as the reference standard. There is limited evidence for the accuracy of selective nerve root injections as a diagnostic tool for lumbosacral disorders. There is limited evidence for their use in the preoperative evaluation of patients with negative or inconclusive imaging studies. The limitations of this systematic review include a paucity of literature, variations in technique, and variable criterion standards for the diagnosis of lumbar radicular pain. There is limited evidence for selective nerve root injections as a diagnostic tool in

  4. Diagnostic development

    International Nuclear Information System (INIS)

    Barnett, C.F.; Brisson, D.A.; Greco, S.E.

    1978-01-01

    During the past year the far-infrared or submillimeter diagnostic research program resulted in three major developments: (1) an optically pumped 0.385-μm D 2 O-laser oscillator-amplifier system was operated at a power level of 1 MW with a line width of less than 50 MHz; (2) a conical Pyrex submillimeter laser beam dump with a retention efficiency greater than 10 4 was developed for the ion temperature Thompson scattering experiment; and (3) a new diagnostic technique was developed that makes use of the Faraday rotation of a modulated submillimeter laser beam to determine plasma current profile. Measurements of the asymmetric distortion of the H/sub α/ (6563 A) spectral line profile show that the effective toroidal drift velocity, dv/sub two vertical bars i/dT/sub i/, may be used as an indicator of plasma quality and as a complement to other ion temperature diagnostics

  5. Technique of Critical Current Density Measurement of Bulk Superconductor with Linear Extrapolation Method

    International Nuclear Information System (INIS)

    Adi, Wisnu Ari; Sukirman, Engkir; Winatapura, Didin S.

    2000-01-01

    Technique of critical current density measurement (Jc) of HTc bulk ceramic superconductor has been performed by using linear extrapolation with four-point probes method. The measurement of critical current density HTc bulk ceramic superconductor usually causes damage in contact resistance. In order to decrease this damage factor, we introduce extrapolation method. The extrapolating data show that the critical current density Jc for YBCO (123) and BSCCO (2212) at 77 K are 10,85(6) Amp.cm - 2 and 14,46(6) Amp.cm - 2, respectively. This technique is easier, simpler, and the use of the current flow is low, so it will not damage the contact resistance of the sample. We expect that the method can give a better solution for bulk superconductor application. Key words. : superconductor, critical temperature, and critical current density

  6. Critical current measurement in superconducting rings using an automatic inductive technique

    International Nuclear Information System (INIS)

    Gonzalez-Jorge, H.; Linares, B.; Quelle, I.; Carballo, E.; Romani, L.; Domarco, G.

    2007-01-01

    A measurement technique was developed to identify the critical current of superconducting rings. It is based on the detection of the voltage on a secondary coil when the current induced in the superconductor by a primary one go beyond to the critical value. The technique uses a DC power supply to control the AC current circulating by the primary circuit. Such circuit mainly consists on an AC power supply which gives a constant AC voltage, a primary inducting coil and a control coil with iron core. The AC current circulating by this circuit is modified with the change in the impedance of the control coil due to the fact of the DC current supplied by the power supply in parallel with it

  7. Development of a diagnostic technique based on Cherenkov effect for measurements of fast electrons in fusion devices

    Energy Technology Data Exchange (ETDEWEB)

    Plyusnin, V. V.; Duarte, P.; Fernandes, H.; Silva, C. [Association Euratom/IST, Instituto de Plasmas e Fusao Nuclear, Instituto Superior Tecnico, Universidade Tecnica de Lisboa, Av. Rovisco Pais, 1049-001 Lisboa (Portugal); Jakubowski, L.; Zebrowski, J.; Malinowski, K.; Rabinski, M.; Sadowski, M. J. [National Centre for Nuclear Research (NCBJ), 7 Andrzeja Soltana Str., 05-400 Otwock (Poland)

    2012-08-15

    A diagnostic technique based on the Cherenkov effect is proposed for detection and characterization of fast (super-thermal and runaway) electrons in fusion devices. The detectors of Cherenkov radiation have been specially designed for measurements in the ISTTOK tokamak. Properties of several materials have been studied to determine the most appropriate one to be used as a radiator of Cherenkov emission in the detector. This technique has enabled the detection of energetic electrons (70 keV and higher) and the determination of their spatial and temporal variations in the ISTTOK discharges. Measurement of hard x-ray emission has also been carried out in experiments for validation of the measuring capabilities of the Cherenkov-type detector and a high correlation was found between the data of both diagnostics. A reasonable agreement was found between experimental data and the results of numerical modeling of the runaway electron generation in ISTTOK.

  8. The current contribution of diagnostic radiology to the population dose in Great Britain

    International Nuclear Information System (INIS)

    Wall, B.F.; Rae, S.; Kendall, G.M.; Darby, S.C.; Fisher, E.S.; Harries, S.V.

    1980-01-01

    An outline account is given of a survey carried out by the NRPB in 1977 to make a reappraisal of the genetically significant dose to the population of Great Britain from diagnostic x-ray examinations. Provisional estimates for the value of the GSD to the population from all diagnostic examinations conducted within the NHS and elsewhere was 17 x 10 -5 Gy (17 mrad). This represented an increase of 20% over the value of 14.1 x 10 -5 Gy (14.1 mrad) found in 1957. This was considered insignificant, considering the errors involved in the surveys. This estimate of GSD is compared with recent estimations in the following countries: Sweden, West Germany, Italy, Romania, Netherlands, USA, Japan, Taiwan, India. The frequency of x-ray examinations per thousand head of population in the U.K. is compared with that of the following countries: West Germany, Switzerland, Netherlands, Japan, USA, Sweden. (U.K.)

  9. USXR Based MHD, Transport, Equilibria and Current Profile Diagnostics for NSTX. Final Report

    International Nuclear Information System (INIS)

    Finkenthal, Michael

    2009-01-01

    The present report resumes the research activities of the Plasma Spectroscopy/Diagnostics Group at Johns Hopkins University performed on the NSTX tokamak at PPPL during the period 1999-2009. During this period we have designed and implemented XUV based diagnostics for a large number of tasks: study of impurity content and particle transport, MHD activity, time-resolved electron temperature measeurements, ELM research, etc. Both line emission and continuum were used in the XUV range. New technics and novel methods have been devised within the framework of the present research. Graduate and post-graduate students have been involved at all times in addition to the senior research personnel. Several tens of papers have been published and lectures have been given based on the obtained results at conferences and various research institutions (lists of these activities were attached both in each proposal and in the annual reports submitted to our supervisors at OFES)

  10. Current status and future perspectives on molecular and serological methods in diagnostic mycology.

    Science.gov (United States)

    Lau, Anna; Chen, Sharon; Sleiman, Sue; Sorrell, Tania

    2009-11-01

    Invasive fungal infections are an important cause of infectious morbidity. Nonculture-based methods are increasingly used for rapid, accurate diagnosis to improve patient outcomes. New and existing DNA amplification platforms have high sensitivity and specificity for direct detection and identification of fungi in clinical specimens. Since laboratories are increasingly reliant on DNA sequencing for fungal identification, measures to improve sequence interpretation should support validation of reference isolates and quality control in public gene repositories. Novel technologies (e.g., isothermal and PNA FISH methods), platforms enabling high-throughput analyses (e.g., DNA microarrays and Luminex xMAP) and/or commercial PCR assays warrant further evaluation for routine diagnostic use. Notwithstanding the advantages of molecular tests, serological assays remain clinically useful for patient management. The serum Aspergillus galactomannan test has been incorporated into diagnostic algorithms of invasive aspergillosis. Both the galactomannan and the serum beta-D-glucan test have value for diagnosing infection and monitoring therapeutic response.

  11. Diagnostic tools for nearest neighbors techniques when used with satellite imagery

    Science.gov (United States)

    Ronald E. McRoberts

    2009-01-01

    Nearest neighbors techniques are non-parametric approaches to multivariate prediction that are useful for predicting both continuous and categorical forest attribute variables. Although some assumptions underlying nearest neighbor techniques are common to other prediction techniques such as regression, other assumptions are unique to nearest neighbor techniques....

  12. Some historic and current aspects of plasma diagnostics using atomic spectroscopy

    Science.gov (United States)

    Hutton, Roger; Zou, Yaming; Andersson, Martin; Brage, Tomas; Martinson, Indrek

    2010-07-01

    In this paper we give a short introduction to the use of atomic spectroscopy in plasma diagnostics. Both older works and exciting new branches of atomic physics, which have relevance to diagnostics, are discussed. In particular we focus on forbidden lines in Be-like ions, lines sensitive to magnetic fields and levels which have a lifetime dependence on the nuclear spin of the ion, i.e. f-dependent lifetimes. Finally we mention a few examples of where tokamaks, instead of needing atomic data, actually provide new data and lead to developments in atomic structure studies. This paper is dedicated to the memory of Nicol J Peacock (1931-2008), a distinguished plasma scientist who contributed much to the field of spectroscopy applied to plasma, and in particular, fusion plasma diagnostics. During the final stages of the preparation of this paper Professor Indrek Martinson passed away peacefully in his sleep on 14 November 2009. Indrek will be greatly missed by many people, both for his contributions to atomic spectroscopy and for his great kindness and friendliness, which many of us experienced.

  13. Current state of a dosimetric evaluation programme in diagnostic radiology installations in Spain

    International Nuclear Information System (INIS)

    Vano, E.; Gonzalez, L.; Calzado, A.; Delgado, V.; Moran, P.; Sanchez, B.; Murias, F.

    1988-01-01

    The Medical Physics Group at the School of Medicine of the Complutense University of Madrid, started a programme on the study of radiation doses in relation to Diagnostic Radiology in the area of Madrid in 1986, in cooperation with the Department of Health and Consumer Affairs, and several Madrid area hospitals as well as some Outpatient Centers. In Spain, the National Health Service (NHS) (through the National Institute of Health, INSALUD), potentially cares for the health of approximately 94% of the population. This figure reaches 99% at the Community of Madrid. Radiological examinations are performed mainly in Hospitals and Outpatient Centers (the latter making up a first link in the patient's radiological diagnosis). Private Diagnostic Radiology is used by the remaining 6% of the population (not taking into account the population attended in military hospitals), and by patients who in spite of having access to NHS Diagnostic Radiology Services, prefer to choose the private sector for different reasons. Besides the data we obtained during the first year of study from four large Madrid-area hospitals (and a few outpatient centers); we have used data furnished by the Department of Health and Consumer Affairs, the INSALUD and other sources

  14. Magnetic diagnostics: General principles and the problem of reconstruction of plasma current and pressure profiles in toroidal systems

    International Nuclear Information System (INIS)

    Pustovitov, V.D.

    2001-01-01

    Restrictions on magnetic diagnostics are discussed. Being related to the integral nature of the measurable quantities, these follow from the fundamental laws of electromagnetism. A series of examples demonstrating the strength of these restrictions is analysed. The general rule is emphasized that information obtained from external magnetic measurements is insufficient for reliable evaluation of plasma current and pressure profiles in tokamaks and in stellarators. The underlying reason is that outside the plasma the self-field of the equilibrium plasma currents is determined by the boundary conditions on the plasma surface alone. (author)

  15. Magnetic diagnostics: general principles and the problem of reconstruction of plasma current and pressure profiles in toroidal systems

    Energy Technology Data Exchange (ETDEWEB)

    Pustovitov, V.D.

    2000-04-01

    The restrictions of the magnetic diagnostics are discussed. Being related to the integral nature of the measurable quantities, they follow from the fundamental laws of electromagnetism. A series of particular examples demonstrating the strength of these restrictions is given and analyzed. A general rule is emphasized that the information obtained from external magnetic measurements is obviously insufficient for the reliable evaluation of plasma current and pressure profiles in tokamaks or in stellarators. The underlying reason is that outside the plasma the own field of the equilibrium plasma currents is determined by the boundary conditions on the plasma surface only. (author)

  16. Development of a neural network technique for KSTAR Thomson scattering diagnostics

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Seung Hun, E-mail: leesh81@nfri.re.kr; Lee, J. H. [National Fusion Research Institute, 169-148 Gwahak-ro, Yuseong-gu, Daejeon 34133 (Korea, Republic of); Yamada, I. [National Institute Fusion Science, Toki, Gifu 509-5292 (Japan); Park, Jae Sun [Department of Physics, Korea Advanced Institute of Science and Technology, 291 Daehak-ro, Yuseong-gu, Daejeon 34141 (Korea, Republic of)

    2016-11-15

    Neural networks provide powerful approaches of dealing with nonlinear data and have been successfully applied to fusion plasma diagnostics and control systems. Controlling tokamak plasmas in real time is essential to measure the plasma parameters in situ. However, the χ{sup 2} method traditionally used in Thomson scattering diagnostics hampers real-time measurement due to the complexity of the calculations involved. In this study, we applied a neural network approach to Thomson scattering diagnostics in order to calculate the electron temperature, comparing the results to those obtained with the χ{sup 2} method. The best results were obtained for 10{sup 3} training cycles and eight nodes in the hidden layer. Our neural network approach shows good agreement with the χ{sup 2} method and performs the calculation twenty times faster.

  17. Current trends in dextranomer hyaluronic acid copolymer (Deflux) injection technique for endoscopic treatment of vesicoureteral reflux.

    Science.gov (United States)

    Kirsch, Andrew J; Arlen, Angela M; Lackgren, Goran

    2014-08-01

    To determine the current preferred injection technique(s) for endoscopic management of pediatric vesicoureteral reflux (VUR). Since the approval of dextranomer hyaluronic acid copolymer (Dx/HA) in 2001, injection methods have evolved and now include the hydrodistention implantation technique (HIT) and double HIT as well as subureteral transurethral injection (STING) method. In July 2012, 278 pediatric urologists in the United States were contacted to complete a 15-question survey regarding Dx/HA injection technique(s) currently used in their practice. Fifty board-certified pediatric urologists completed the survey for a response rate of 18%. Most respondents (60%) were in a single-specialty group practice, and 12% were affiliated with an academic- or university-based practice. Respondents reported seeing a mean of 159 pediatric patients (range, 40-400 patients) with VUR annually, and 94% used Dx/HA ≥4 times in the past year. Forty-seven respondents (94%) reported using double HIT over the course of their career compared with 36 (72%) for STING and 30 (60%) for HIT (P injection techniques. A significantly higher percentage currently perform double HIT (92%) compared with either STING (24%) or HIT (34%; P <.001). Respondents reported the use of double HIT 15 times more often than STING technique and 5 times more often than HIT during the past 12 months (P <.001). The double HIT method is currently the most commonly performed technique for endoscopic correction of VUR by pediatric urologists in the United States. Copyright © 2014 Elsevier Inc. All rights reserved.

  18. Diagnostics of glass fiber reinforced polymers and comparative analysis of their fabrication techniques with the use of acoustic emission

    Science.gov (United States)

    Bashkov, O. V.; Bryansky, A. A.; Panin, S. V.; Zaikov, V. I.

    2016-11-01

    Strength properties of the glass fiber reinforced polymers (GFRP) fabricated by vacuum and vacuum autoclave molding techniques were analyzed. Measurements of porosity of the GFRP parts manufactured by various molding techniques were conducted with the help of optical microscopy. On the basis of experimental data obtained by means of acoustic emission hardware/software setup, the technique for running diagnostics and forecasting the bearing capacity of polymeric composite materials based on the result of three-point bending tests has been developed. The operation principle of the technique is underlined by the evaluation of the power function index change which takes place on the dependence of the total acoustic emission counts versus the loading stress.

  19. Flowfield modeling and diagnostics

    International Nuclear Information System (INIS)

    Gupta, A.K.; Lilley, D.G.

    1985-01-01

    This textbook is devoted solely to flowfield modeling and diagnostics; their practical use, recent and current research, and projected developments and trends. It provides an account of the use of a broad range of techniques in industrial and research practice, both with and without combustion. Application ideas are complemented by details about experimental and modeling techniques

  20. Estimating the burden of pneumococcal pneumonia among adults: a systematic review and meta-analysis of diagnostic techniques.

    Directory of Open Access Journals (Sweden)

    Maria A Said

    Full Text Available Pneumococcal pneumonia causes significant morbidity and mortality among adults. Given limitations of diagnostic tests for non-bacteremic pneumococcal pneumonia, most studies report the incidence of bacteremic or invasive pneumococcal disease (IPD, and thus, grossly underestimate the pneumococcal pneumonia burden. We aimed to develop a conceptual and quantitative strategy to estimate the non-bacteremic disease burden among adults with community-acquired pneumonia (CAP using systematic study methods and the availability of a urine antigen assay.We performed a systematic literature review of studies providing information on the relative yield of various diagnostic assays (BinaxNOW® S. pneumoniae urine antigen test (UAT with blood and/or sputum culture in diagnosing pneumococcal pneumonia. We estimated the proportion of pneumococcal pneumonia that is bacteremic, the proportion of CAP attributable to pneumococcus, and the additional contribution of the Binax UAT beyond conventional diagnostic techniques, using random effects meta-analytic methods and bootstrapping. We included 35 studies in the analysis, predominantly from developed countries. The estimated proportion of pneumococcal pneumonia that is bacteremic was 24.8% (95% CI: 21.3%, 28.9%. The estimated proportion of CAP attributable to pneumococcus was 27.3% (95% CI: 23.9%, 31.1%. The Binax UAT diagnosed an additional 11.4% (95% CI: 9.6, 13.6% of CAP beyond conventional techniques. We were limited by the fact that not all patients underwent all diagnostic tests and by the sensitivity and specificity of the diagnostic tests themselves. We address these resulting biases and provide a range of plausible values in order to estimate the burden of pneumococcal pneumonia among adults.Estimating the adult burden of pneumococcal disease from bacteremic pneumococcal pneumonia data alone significantly underestimates the true burden of disease in adults. For every case of bacteremic pneumococcal pneumonia

  1. A New Paradigm for Tissue Diagnostics: Tools and Techniques to Standardize Tissue Collection, Transport, and Fixation.

    Science.gov (United States)

    Bauer, Daniel R; Otter, Michael; Chafin, David R

    2018-01-01

    Studying and developing preanalytical tools and technologies for the purpose of obtaining high-quality samples for histological assays is a growing field. Currently, there does not exist a standard practice for collecting, fixing, and monitoring these precious samples. There has been some advancement in standardizing collection for the highest profile tumor types, such as breast, where HER2 testing drives therapeutic decisions. This review examines the area of tissue collection, transport, and monitoring of formalin diffusion and details a prototype system that could be used to help standardize tissue collection efforts. We have surveyed recent primary literature sources and conducted several site visits to understand the most error-prone processes in histology laboratories. This effort identified errors that resulted from sample collection techniques and subsequent transport delays from the operating room (OR) to the histology laboratories. We have therefore devised a prototype sample collection and transport concept. The system consists of a custom data logger and cold transport box and takes advantage of a novel cold + warm (named 2 + 2) fixation method. This review highlights the beneficial aspects of standardizing tissue collection, fixation, and monitoring. In addition, a prototype system is introduced that could help standardize these processes and is compatible with use directly in the OR and from remote sites.

  2. Development of Eddy Current Technique for Reactor In-Core Flux Thimble Wear

    International Nuclear Information System (INIS)

    Park, S. S.; Jang, Y. Y.; Yim, C. Y.; Park, K. H.

    1990-01-01

    Since in-core flux thimble tube wear the due to flow-induced vibration could degrade the integrity of nuclear reactor, the effective detection and interpretation of the wear is important. In order to establish an inspection technique for thimble tubes, an eddy current experiment was performed to determine the optimum test frequency, defect sensitivity and evaluation accuracy. Eddy current probes were designed and fabricated with a theory. Specimens with artificial defects were fabricated using electro discharge machining method. The results from inspection technique developed and on-site inspection showed good applicability

  3. Nondestructive evaluation of a cermet coating using ultrasonic and eddy current techniques

    International Nuclear Information System (INIS)

    Roge, B.; Fahr, A.; Giguere, J.S.R.; McRae, K.I.

    2002-01-01

    This paper describes a series of experiments conducted to characterize cermet coatings using conventional ultrasonic and eddy current techniques as well as an ultrasonic leaky surface wave method. The results demonstrate the ability of these techniques to detect the presence of artificial defects on the surface or beneath the surface of the coating. In addition, ultrasonic tests in particular ultrasonic leaky surface waves demonstrate the ability to detect the presence of manufacturing flaws. Ultrasonic time-of-flight and eddy current quadrature measurements also show sensitivity to variations in coating thickness

  4. Study of pulse stretching in high current power supplies using multipulse techniques

    International Nuclear Information System (INIS)

    Trendler, R.C.

    1977-01-01

    Considerable interest exists at Fermilab to increase the pulse width of the Neutrino Focusing Horn to permit an increase in beam spill length from twenty (20) microseconds to one (1) millisecond. Two techniques to do this were examined: (1) a high current transformer, and (2) increased bank capacitance using the multi-power supply technique. The transformer is the most straightforward conceptually; it is, however, a complicated device requiring sizable changes to the existing horn power supply. This alternative is briefly reviewed. The second scheme involves pulsing a 20 kv 200 ka power supply to establish the required load current and then maintaining this current by the sequential pulsing of a number of low voltage high current power supplies. This alternative is discussed in detail with the results of tests performed on the Fermilab Focusing Horn System

  5. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    Energy Technology Data Exchange (ETDEWEB)

    Pua, Uei; Tan, Cher Heng [Tan Tock Seng Hospital, Department of Diagnostic Radiology, Singapore (Singapore); Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong [Tan Tock Seng Hospital, Department of Cardiology, Singapore (Singapore)

    2014-08-28

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  6. Revisiting renovascular imaging for renal sympathetic denervation: current techniques and applications

    International Nuclear Information System (INIS)

    Pua, Uei; Tan, Cher Heng; Ho, Hee Hwa; Tan, Julian Ko Beng; Ong, Paul Jau Leong

    2015-01-01

    Renal sympathetic denervation (RDN) is an emerging technique in the treatment of resistant hypertension, most commonly performed using an endovascular approach. Clinical and anatomical criteria for RDN are well established and imaging plays an integral role in selecting patients with suitable anatomy, procedural planning and device selection. Nevertheless, the current body of literature surrounding imaging related to RDN remains limited. The purpose of this article is to illustrate the expectations and limitations of various imaging techniques, including Doppler ultrasound, CT angiography, MR angiography and newer techniques such as non-contrast MR angiography, in the context of RDN. (orig.)

  7. Detection and Sizing of Fatigue Cracks in Steel Welds with Advanced Eddy Current Techniques

    Science.gov (United States)

    Todorov, E. I.; Mohr, W. C.; Lozev, M. G.

    2008-02-01

    Butt-welded specimens were fatigued to produce cracks in the weld heat-affected zone. Advanced eddy current (AEC) techniques were used to detect and size the cracks through a coating. AEC results were compared with magnetic particle and phased-array ultrasonic techniques. Validation through destructive crack measurements was also conducted. Factors such as geometry, surface treatment, and crack tightness interfered with depth sizing. AEC inspection techniques have the potential of providing more accurate and complete sizing flaw data for manufacturing and in-service inspections.

  8. Integration of PET/CT in Current Diagnostic and Response Evaluation Methods in Patients with Tuberculosis

    International Nuclear Information System (INIS)

    Oezmen, Oelem; Goekcek, Atila; Tatci, Ebru; Biner, Inci; Akkalyoncu, Behiye

    2014-01-01

    Tuberculosis is a systemic disease that still affects many people. While pleural involvement is frequently observed in extrapulmonary tuberculosis, multiple skeletal system and articular involvements are quite rare. FDG PET imaging could be a promising diagnostic and treatment monitoring method, especially in complicated cases and if the other methods are inadequate. In this case study, we report a patient who was admitted with suspected malignancy and then diagnosed with tuberculosis pleuritis, lymphadenitis, spondylodiscitis, and sacroiliitis with specific symptoms; the response to anti-tuberculosis therapy was shown using FDG PET/CT

  9. Screening for Wilson disease in acute liver failure: a comparison of currently available diagnostic tests

    DEFF Research Database (Denmark)

    Korman, J.D.; Volenberg, I.; Balko, J.

    2008-01-01

    a diagnostic sensitivity of 21% and specificity of 84% while, by nephelometry, a sensitivity of 56% and specificity of 63%. Serum copper levels exceeded 200 microg/dL in all ALF-WD patients measured (13/16), but were also elevated in non-WD ALF. An alkaline phosphatase (AP) to total bilirubin (TB) ratio ... and specificity of 100%. CONCLUSION: Conventional WD testing utilizing serum ceruloplasmin and/or serum copper levels are less sensitive and specific in identifying patients with ALF-WD than other available tests. More readily available laboratory tests including alkaline phosphatase, bilirubin and serum...

  10. Integration of PET/CT in Current Diagnostic and Response Evaluation Methods in Patients with Tuberculosis

    Energy Technology Data Exchange (ETDEWEB)

    Oezmen, Oelem; Goekcek, Atila; Tatci, Ebru; Biner, Inci; Akkalyoncu, Behiye [Atatuerk Chest Diseases and Thoracic Surgery Training and Research Hospital, Ankara (Turkmenistan)

    2014-03-15

    Tuberculosis is a systemic disease that still affects many people. While pleural involvement is frequently observed in extrapulmonary tuberculosis, multiple skeletal system and articular involvements are quite rare. FDG PET imaging could be a promising diagnostic and treatment monitoring method, especially in complicated cases and if the other methods are inadequate. In this case study, we report a patient who was admitted with suspected malignancy and then diagnosed with tuberculosis pleuritis, lymphadenitis, spondylodiscitis, and sacroiliitis with specific symptoms; the response to anti-tuberculosis therapy was shown using FDG PET/CT.

  11. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes. Determination of hydrogen concentration and blister characterization

    International Nuclear Information System (INIS)

    2009-03-01

    Heavy water reactors (HWRs) comprise significant numbers of today's operating nuclear power plants, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems, especially pressure tubes, are an important factor in ensuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Project (CRP) on Intercomparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the framework of the IAEA's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of IAEA's project on advanced technologies for HWRs. The objective of the CRP was to compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP participants investigated the capability of different techniques to detect and characterize flaws. During the second phase participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in zirconium alloys. The intention was to identify the most effective pressure tube inspection and diagnostic methods and to identify further development needs. The organizations which participated in phase 2 of this CRP are: - Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL), Chalk River Laboratories (CRL), Canada; - Bhabha Atomic Research Centre (BARC), India; - Korea Atomic Energy Research Institute (KAERI), Republic of Korea; - National Institute for Research and Development for Technical Physics (NIRDTP), Romania; - Nuclear Non-Destructive Testing Research and Services (NNDT), Romania. IAEA-TECDOC-1499

  12. Principles for new optical techniques in medical diagnostics for mHealth applications

    Science.gov (United States)

    Balsam, Joshua Michael

    Medical diagnostics is a critical element of effective medical treatment. However, many modern and emerging diagnostic technologies are not affordable or compatible with the needs and conditions found in low-income and middle-income countries and regions. Resource-poor areas require low-cost, robust, easy-to-use, and portable diagnostics devices compatible with telemedicine (i.e. mHealth) that can be adapted to meet diverse medical needs. Many suitable devices will need to be based on optical technologies, which are used for many types of biological analyses. This dissertation describes the fabrication and detection principles for several low-cost optical technologies for mHealth applications including: (1) a webcam based multi-wavelength fluorescence plate reader, (2) a lens-free optical detector used for the detection of Botulinum A neurotoxin activity, (3) a low cost micro-array reader that allows the performance of typical fluorescence based assays demonstrated for the detection of the toxin staphylococcal enterotoxin (SEB), and (4) a wide-field flow cytometer for high throughput detection of fluorescently labeled rare cells. This dissertation discusses how these technologies can be harnessed using readily available consumer electronics components such as webcams, cell phones, CCD cameras, LEDs, and laser diodes. There are challenges in developing devices with sufficient sensitivity and specificity, and approaches are presented to overcoming these challenges to create optical detectors that can serve as low cost medical diagnostics in resource-poor settings for mHealth.

  13. Development of in situ cleaning techniques for diagnostic mirrors in ITER

    International Nuclear Information System (INIS)

    Litnovsky, A.; Laengner, M.; Matveeva, M.; Schulz, Ch.; Marot, L.; Voitsenya, V.S.; Philipps, V.; Biel, W.; Samm, U.

    2011-01-01

    Mirrors will be used in all optical and laser-based diagnostic systems of ITER. In the severe environment, the optical characteristics of mirrors will be degraded, hampering the entire performance of the respective diagnostics. A minute impurity deposition of 20 nm of carbon on the mirror is sufficient to decrease the mirror reflectivity by tens of percent outlining the necessity of the mirror cleaning in ITER. The results of R and D on plasma cleaning of molybdenum diagnostic mirrors are reported. The mirrors contaminated with amorphous carbon films in the laboratory conditions and in the tokamaks were cleaned in steady-state hydrogenic plasmas. The maximum cleaning efficiency of 4.2 nm/min was reached for the laboratory and soft tokamak hydrocarbon films, whereas for the hard tokamak films the carbidization of mirrors drastically decreased the cleaning efficiency down to 0.016 nm/min. This implies the necessity of sputtering cleaning of contaminated mirrors as the only reliable tool to remove the deposits by plasma cleaning. An overview of R and D program on mirror cleaning is provided along with plans for further studies and the recommendations for ITER mirror-based diagnostics.

  14. Draft of diagnostic techniques for primary coolant circuit facilities using control computer

    International Nuclear Information System (INIS)

    Suchy, R.; Procka, V.; Murin, V.; Rybarova, D.

    A method is proposed of in-service on-line diagnostics of primary circuit selected parts by means of a control computer. Computer processing will involve the measurements of neutron flux, pressure difference in pumps and in the core, and the vibrations of primary circuit mechanical parts. (H.S.)

  15. Current role of the radiographers in imaging diagnostics, nuclear medicine and radiotherapy in modern departments

    International Nuclear Information System (INIS)

    Karidova, S.; Velkova, K.; Panamska, K.; Petkova, K.

    2006-01-01

    Full text: In the communication we set out to focus the attention of the medical staff and the public on the place and the constantly growing role (relative burden) of the radiographers in imaging diagnostics, nuclear medicine and radiotherapy in the field of modern medicine. The advanced radiographers level and rapid development of the contemporary equipment and apparatuses used in imaging diagnostics, nuclear medicine and radiotherapy, as well as the methods of their utilization, presuppose very good and constantly improving theoretical and practical training of the imaging technician. The radiographer fulfills responsible tasks under the guidance of the physician or independently and bears specific responsibilities. Having mastered the fundamentals of radiation protection, the imaging technician protects both himself and the patient from the impact of ionizing radiation. To be able to fulfill his/her constantly increasing duties and obligations, the imaging radiographer has acquired wide knowledge of general education subjects, subjects of general medicine and special subjects. The radiographer has a good knowledge of Latin and a modern foreign language, and he is also computer literate so as to be able to cope with the widely spread visualizing methods. The radiographer acquires additional post-graduate training to work in narrowly specialized fields as well as to improve his/her qualifications

  16. Current status of diagnostic imaging in dental university hospitals in Japan

    International Nuclear Information System (INIS)

    Sasaki, Takehito; Fujita, Minoru; Katoh, Tsuguhisa; Kobayashi, Kaoru; Okano, Tomohiro; Sato, Kenji; Wada, Shinichi

    2004-01-01

    The diagnostic imaging examinations in all 29 dental university hospitals in Japan were analyzed during a 1-year period from April 1999 to March 2000. The total number of patients examined was 790859, which corresponded to 27271 patients per hospital on average, with a range from 7872 to 62904. Relative to the total number of patients, intraoral radiography was found to have been most frequently performed, 59% on average, with a range from 40% to 80%, depending on the hospital. Extraoral radiography, mostly panoramic radiography, was 36% on average with the range from 18% to 56%. A significant inverse correlation was observed between the percentages of intraoral and extraoral radiography, relative to the total number of all types of imaging examinations. Computed tomography (CT) examinations were performed with their own apparatuses in 27 hospitals with a frequency of 2.9% of patients in all imaging examinations on average and 9.1% at maximum. The scanning parameter of milliampere seconds (mAs) for individual types of routinely performed CT examinations varied widely, and thus the patient dose can be expected to be considerably reduced, without reducing the amount of diagnostic information to be obtained. Other imaging examinations performed were magnetic resonance imaging in 11 hospitals, X-ray fluoroscopy in 8 hospitals, ultrasonography in 20, nuclear medicine in 5, and bone densitometry in 1 hospital. (author)

  17. Diagnostic merits of current and potential applications of single photon and positron imaging: a perspective

    Energy Technology Data Exchange (ETDEWEB)

    Harper, P. V.

    1978-01-01

    A brief review of the limitations of medical radionuclide imaging techniques in competition with x-ray CAT scanning and ultrasound suggest that the emphasis in this are should be on measurement of the physiologic uptake of tracer materials. Tomography greatly improves the possibilities of quantitation of this uptake - examples using positron and single photon techniques are presented for /sup 13/NH/sub 3/ and /sup 201/Tl in the heart.

  18. Diagnostic merits of current and potential applications of single photon and positron imaging: a perspective

    International Nuclear Information System (INIS)

    Harper, P.V.

    1978-01-01

    A brief review of the limitations of medical radionuclide imaging techniques in competition with x-ray CAT scanning and ultrasound suggest that the emphasis in this are should be on measurement of the physiologic uptake of tracer materials. Tomography greatly improves the possibilities of quantitation of this uptake - examples using positron and single photon techniques are presented for 13 NH 3 and 201 Tl in the heart

  19. Modern endoscopic techniques of precancerous stomach conditions diagnostics: problems and possibilities

    Directory of Open Access Journals (Sweden)

    Yu.M. Stepanov

    2017-02-01

    Full Text Available The review shows the classification of precancerous stomach pathology, proposed in the Consensus Management of precancerous conditions and lesions in the stomach (MAPS (2012, according to which they are divided into precancerous lesions (atrophic gastritis and intestinal metaplasia and precancerous changes (stomach mucosa dysplasia. Chronic atrophic gastritis and intestinal metaplasia are considered precancerous conditions, as they are the background for development of dysplasia and gastric adenocarcinoma of intestinal type. Precancerous changes is gastric dysplasia and is the penultimate stage of gastric carcinogenesis sequence and is defined as histologically clear tumor epithelium without signs of infection, and thus is a direct tumor precancerous lesions. It is noted that, in general, the risk of stomach cancer is too small to justify by endoscopic observation in all the patients with atrophic gastritis and intestinal metaplasia. Thus, it is necessary to define additional risk factors for stomach cancer progression in that it is presented in the Kyoto global consensus on Helicobacter pylori-associated gastritis (2015 for this category of patients. It was determined that stomach cancer risk factors are the intragastric distribution and the extent of intestinal metaplasia, presence of a family history of gastric cancer, the definition of subtypes of intestinal metaplasia. Sydney system is used for chronic gastritis classification (Houston review, as well as classification by metaplasia type (non-metaplastic, metaplastic atrophy of uncertain type. There are three methods to determine the prevalence and extent of atrophic gastritis and intestinal metaplasia used: endoscopic, histological and serological. The atrophy severity of the gastric mucosa is determined histologically. Classification of atrophy severity by endoscopic parameters does not currently exist. Intestinal metaplasia developed in different parts of the stomach and is multifocal

  20. Current techniques in postmortem imaging with specific attention to paediatric applications

    International Nuclear Information System (INIS)

    Sieswerda-Hoogendoorn, Tessa; Rijn, Rick R. van

    2010-01-01

    In this review we discuss the decline of and current controversies regarding conventional autopsies and the use of postmortem radiology as an adjunct to and a possible alternative for the conventional autopsy. We will address the radiological techniques and applications for postmortem imaging in children. (orig.)

  1. Current techniques in postmortem imaging with specific attention to paediatric applications

    Energy Technology Data Exchange (ETDEWEB)

    Sieswerda-Hoogendoorn, Tessa; Rijn, Rick R. van [Academic Medical Centre Amsterdam, Department of Radiology, Amsterdam Zuid-Oost (Netherlands); Netherlands Forensic Institute, Department of Pathology and Toxicology, The Hague (Netherlands)

    2010-02-15

    In this review we discuss the decline of and current controversies regarding conventional autopsies and the use of postmortem radiology as an adjunct to and a possible alternative for the conventional autopsy. We will address the radiological techniques and applications for postmortem imaging in children. (orig.)

  2. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    Science.gov (United States)

    Krauter, N.; Stefani, F.

    2017-10-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation.

  3. Immersed transient eddy current flow metering: a calibration-free velocity measurement technique for liquid metals

    International Nuclear Information System (INIS)

    Krauter, N; Stefani, F

    2017-01-01

    Eddy current flow meters are widely used for measuring the flow velocity of electrically conducting fluids. Since the flow induced perturbations of a magnetic field depend both on the geometry and the conductivity of the fluid, extensive calibration is needed to get accurate results. Transient eddy current flow metering has been developed to overcome this problem. It relies on tracking the position of an impressed eddy current system that is moving with the same velocity as the conductive fluid. We present an immersed version of this measurement technique and demonstrate its viability by numerical simulations and a first experimental validation. (paper)

  4. The simple analytical method for scattered radiation calculation in contrast X-ray diagnostic techniques

    Energy Technology Data Exchange (ETDEWEB)

    Markovic, S; Pavlovic, R [Inst. of Nuclear Science Vinca, Belgrade (Yugoslavia). Radiation and Environmental Protection Lab.; Boreli, F [Fac. of Electrical Engineering, Belgrade (Yugoslavia)

    1996-12-31

    In realization of radiation protection measures for medical staff present during diagnostic procedures, the necessary condition is knowledge of the space - energy distributions of the scattered radiation from the patient. In this paper, the simple calculation procedure for the scattered radiation field of the actual diagnostic energies is presented. Starting from the single Compton scattering model and using the justified transformations the final equations in elementary form are derived. For numerical calculations the computer code ANGIO was created. The calculated results were confirmed by detailed dosimetric measurements of the scattered field around patient (the water phantom) in SSDL in the Institute of nuclear sciences `Vinca`, Belgrade. These results are good base for assessment of irradiation. The main irradiation source for the physician and the other members of the medical team is the back scattered radiation from patient - albedo. (author). 3 figs., 3 refs.

  5. A novelty detection diagnostic methodology for gearboxes operating under fluctuating operating conditions using probabilistic techniques

    Science.gov (United States)

    Schmidt, S.; Heyns, P. S.; de Villiers, J. P.

    2018-02-01

    In this paper, a fault diagnostic methodology is developed which is able to detect, locate and trend gear faults under fluctuating operating conditions when only vibration data from a single transducer, measured on a healthy gearbox are available. A two-phase feature extraction and modelling process is proposed to infer the operating condition and based on the operating condition, to detect changes in the machine condition. Information from optimised machine and operating condition hidden Markov models are statistically combined to generate a discrepancy signal which is post-processed to infer the condition of the gearbox. The discrepancy signal is processed and combined with statistical methods for automatic fault detection and localisation and to perform fault trending over time. The proposed methodology is validated on experimental data and a tacholess order tracking methodology is used to enhance the cost-effectiveness of the diagnostic methodology.

  6. Current and Potential Developments of Cortisol Aptasensing towards Point-of-Care Diagnostics (POTC

    Directory of Open Access Journals (Sweden)

    Azrul Syafiq Zainol Abidin

    2017-05-01

    Full Text Available Anxiety is a psychological problem that often emerges during the normal course of human life. The detection of anxiety often involves a physical exam and a self-reporting questionnaire. However, these approaches have limitations, as the data might lack reliability and consistency upon application to the same population over time. Furthermore, there might be varying understanding and interpretations of the particular question by the participant, which necessitating the approach of using biomarker-based measurement for stress diagnosis. The most prominent biomarker related to stress, hormone cortisol, plays a key role in the fight-or-flight situation, alters the immune response, and suppresses the digestive and the reproductive systems. We have taken the endeavour to review the available aptamer-based biosensor (aptasensor for cortisol detection. The potential point-of-care diagnostic strategies that could be harnessed for the aptasensing of cortisol were also envisaged.

  7. High precision electron beam diagnostic system for high current long pulse beams

    International Nuclear Information System (INIS)

    Chen, Y J; Fessenden, T; Holmes, C; Nelson, S D; Selchow, N.

    1999-01-01

    As part of the effort to develop a multi-axis electron beam transport system using stripline kicker technology for DARHT II applications, it is necessary to precisely determine the position and extent of long high energy beams (6-40 MeV, 1-4 kA, 2 microseconds) for accurate position control. The kicker positioning system utilizes shot-to-shot adjustments for reduction of relatively slow (<20 MHz) motion of the beam centroid. The electron beams passing through the diagnostic systems have the potential for large halo effects that tend to corrupt measurements performed using capacitive pick-off probes. Likewise, transmission line traveling wave probes have problems with multi-bounce effects due to these longer pulse widths. Finally, the high energy densities experienced in these applications distort typical foil beam position measurements

  8. Current updates on diagnostic methodologies for tick-borne hemoparasitic diseases in equids: A review

    Directory of Open Access Journals (Sweden)

    Lawan Adamu

    2016-06-01

    Full Text Available Tick-borne diseases (TBDs or otherwise called equine piroplasmosis (EP are the foremost economic limitations to equids production. Thus, reducing the breeding capability and athletic performance of equids globally. Identification of these haemoparasites is crucial in understanding their distribution in the population and it is imperative to discern between species and subspecies that are responsible for the occurrence of the disease conditions. Conventional procedures such as microscopic and serological evaluations do not usually meet these prerequisites. Diagnostic contrivances, such as the complement fixation test (CFT, the indirect fluorescent antibody test (IFAT and the enzyme linked immunosorbent assay (ELISA have been efficaciously used for many years. Furthermore, DNA-based investigations for identification, differentiation and classification of different haemoparasites have also been established. Molecular diagnostic procedures, such as DNA hybridization, polymerase chain reaction (PCR, transcriptomics, proteomics, metagenomics and metabolomics, permit the uncovering of parasites in blood, tissues or ticks with optimal sensitivity, specificity and consistency. In addition, these procedures can be exploited to detect definite species and subspecies. The prerequisite of these investigations must include proper premeditation and validation, these investigations provide an effective device for molecular studies, with greater benefits of flexibility to standardization. The application of these procedures for studying TBDs or EP globally will be irreplaceable for a long period from now. Therefore, the aim of this review is to draw up the specifics of the procedures in more convenient form for practitioners and researchers. KEY WORDS: Diagnosis, equids, molecular, transcriptomics, proteomics, metagenomics, metabolomics, haemoparasites, tick-borne diseases [J Adv Vet Anim Res 2016; 3(2.000: 84-91

  9. Application of the SWE-to-PWE antenna diagnostics technique to an offset reflector antenna

    DEFF Research Database (Denmark)

    Cappellin, Cecilia; Frandsen, Aksel; Breinbjerg, Olav

    2008-01-01

    Electrical and mechanical errors in an antenna may seriously affect the antenna's performance. Although their presence is usually detected by anomalies in the antenna's far-field pattern, their identification is normally possible only through an analysis of the antenna's extreme near field....... The reconstruction of the extreme near field on the basis of near- or far-field measurements is thus an essential step in antenna diagnostics....

  10. On the estimation of the current density in space plasmas: Multi- versus single-point techniques

    Science.gov (United States)

    Perri, Silvia; Valentini, Francesco; Sorriso-Valvo, Luca; Reda, Antonio; Malara, Francesco

    2017-06-01

    Thanks to multi-spacecraft mission, it has recently been possible to directly estimate the current density in space plasmas, by using magnetic field time series from four satellites flying in a quasi perfect tetrahedron configuration. The technique developed, commonly called ;curlometer; permits a good estimation of the current density when the magnetic field time series vary linearly in space. This approximation is generally valid for small spacecraft separation. The recent space missions Cluster and Magnetospheric Multiscale (MMS) have provided high resolution measurements with inter-spacecraft separation up to 100 km and 10 km, respectively. The former scale corresponds to the proton gyroradius/ion skin depth in ;typical; solar wind conditions, while the latter to sub-proton scale. However, some works have highlighted an underestimation of the current density via the curlometer technique with respect to the current computed directly from the velocity distribution functions, measured at sub-proton scales resolution with MMS. In this paper we explore the limit of the curlometer technique studying synthetic data sets associated to a cluster of four artificial satellites allowed to fly in a static turbulent field, spanning a wide range of relative separation. This study tries to address the relative importance of measuring plasma moments at very high resolution from a single spacecraft with respect to the multi-spacecraft missions in the current density evaluation.

  11. Diagnostic Accuracy of Imaging Modalities and Injection Techniques for the Diagnosis of Femoroacetabular Impingement/Labral Tear

    DEFF Research Database (Denmark)

    Reiman, Michael P.; Thorborg, Kristian; Goode, Adam P.

    2017-01-01

    Background: Diagnosing femoroacetabular impingement/acetabular labral tear (FAI/ALT) and subsequently making a decision regarding surgery are based primarily on diagnostic imaging and intra-articular hip joint injection techniques of unknown accuracy. Purpose: Summarize and evaluate the diagnostic...... probability of disease was demonstrated. Positive imaging findings increased the probability that a labral tear existed by a minimal to small degree with the use of magnetic resonance imaging/magnetic resonance angiogram (MRI/MRA) and ultrasound (US) and by a moderate degree for CTA. Negative imaging findings...... decreased the probability that a labral tear existed by a minimal degree with the use of MRI and US, a small to moderate degree with MRA, and a moderate degree with CTA. Clinical Relevance: Although findings of the included studies suggested potentially favorable use of these modalities for the diagnosis...

  12. Development of an eddy current inspection technique for sleeved engine disk bolt holes

    International Nuclear Information System (INIS)

    Palanisamy, R.; Lakin, K.M.

    1983-01-01

    Recent research programs have concentrated mainly on developing techniques to characterize surface breaking cracks and very little has been done towards characterizing subsurface flaws in conducting materials. Presented in this paper are the results of some initial theoretical work aimed at the development of a reliable eddy current technique to detect and characterize defects in engine disk bolt holes under a 0.05'' stainless steel sleeve. The change in impedance of an absolute eddy current coil with and without ferrite core, and the distribution of eddy currents around a second layer crack with and without a thin insulating film between the two conducting layers have been predicted numerically. The overall system development goals and methods to accomplish them are outlined briefly

  13. Application of an eddy current technique to steam generator U-bend characterization. Final report

    International Nuclear Information System (INIS)

    Cramer, W.E.; de la Pintiere, L.; Narita, S.; Bergander, M.J.

    1982-04-01

    Eddy current nondestructive testing techniques are used widely throughout the utility industry for the early detection of tube damage in critical power plant components such as steam generators. In this project, the application of an eddy current technique for the characterization of U-bend transitions in the first row tubing in Westinghouse 51 Series Steam Generators has been investigated. A method has been developed for detection of the opposite transition in the U-bend and for defining its severity. Investigation included two different types of U-bend transitions. Using the developed eddy current method for U-bend characterization, on-site inspection was performed on all tubes in the first row in four 51 Series steam generators in Power Plant Unit No. 2 and in one 51 Series steam generator in Power Plant Unit No. 1. The advantages and limitations of the developed method as well as the recommendations for further investigations are included

  14. Current activities in development of PIE techniques in JMTR hot laboratory

    International Nuclear Information System (INIS)

    Ishii, Toshimitsu; Ohmi, Masao; Shimizu, Michio; Kaji, Yoshiyuki; Ueno, Fumiyoshi

    2006-01-01

    A wide variety of post-irradiation examinations (PIEs) for research and development of nuclear fuels and materials to be utilized in nuclear field has been carried out since 1971 in three kinds of β-γ hot cells; concrete, lead and steel cells in the JMTR Hot Laboratory (JMTR HL) associated with the Japan Materials Testing Reactor (JMTR). In addition to PIEs, the re-capsuling work including re-instrumentation was also conducted for the power ramping tests of the irradiated LWR fuels using Boiling Water Capsule (BOCA). Recently, new PIE techniques are required for the advanced irradiation studies. In this paper, the irradiation assisted stress corrosion cracking (IASCC) growth test technique of irradiated in-core structural materials and the remote operation technique of the atomic force microscope (AFM) are described as JMTR HL's current activities in the development of new PIE techniques. (author)

  15. Optical spectroscopy: current advances and future applications in cancer diagnostics and therapy

    NARCIS (Netherlands)

    Evers, Daniel; Evers, D.J.; Hendriks, B.; Lucassen, G.W.; Lucassen, Gerald; Ruers, Theo J.M.

    2012-01-01

    Optical spectroscopy (OS) is a tissue-sensing technique that could enhance cancer diagnosis and treatment in the near future. With OS, tissue is illuminated with a selected light spectrum. Different tissue types can be distinguished from each other based on specific changes in the reflected light

  16. [Treatment of Hallux Valgus: Current Diagnostic Testing and Surgical Treatment Performed by German Foot and Ankle Surgeons].

    Science.gov (United States)

    Arbab, Dariusch; Schneider, Lisa-Maria; Schnurr, Christoph; Bouillon, Bertil; Eysel, Peer; König, Dietmar Pierre

    2018-04-01

    Hallux valgus is one of the most prevalent foot deformities, and surgical treatment of Hallux valgus is one of the most common procedures in foot and ankle surgery. Diagnostic and treatment standards show large variation despite medical guidelines and national foot and ankle societies. The aim of this nationwide survey is a description of the current status of diagnostics and therapy of Hallux valgus in Germany. A nationwide online questionnaire survey was sent to two German foot and ankle societies. The participants were asked to answer a questionnaire of 53 questions with four subgroups (general, diagnostics, operation, preoperative management). Surgical treatment for three clinical cases demonstrating a mild, moderate and severe Hallux valgus deformity was inquired. 427 foot and ankle surgeons answered the questionnaire. 388 participants were certified foot and ankle surgeons from one or both foot and ankle societies. Medical history (78%), preoperative radiographs (100%) and preoperative radiographic management (78%) are of high or very high importance for surgical decision pathway. Outcome scores are used by less than 20% regularly. Open surgery is still the gold standard, whereas minimally invasive surgery is performed by only 7%. Our survey showed that diagnostic standards are met regularly. There is a wide variation in the type of procedures used to treat Hallux valgus deformity. TMT I arthrodesis is preferred in severe Hallux valgus, but also used to treat moderate and mild deformities. Minimally invasive surgery is still used by a minority of surgeons. It remains to be seen, to what extent minimally invasive surgery will be performed in the future. Georg Thieme Verlag KG Stuttgart · New York.

  17. Contribution to the current value of cerebrospinal fluid scintiscanning in neurological diagnostics

    International Nuclear Information System (INIS)

    Kukowski, B.

    1983-01-01

    The importance of scintiscanning of the subarachnoid space of the diagnosis and treatment of certain diseases, and the value of this method within the diagnostical instrumentarium were investigated on the basis of different indications. As a result it was found that scintiscanning of the subarachnoid space can to a large extent be dispensed with. In the remaining indications, by contrast, subarachnoid space scintiscanning is an important test disclosing the causes and extent of liquor circulation disturbances. It is particularly useful if completed by computerized tomography which provides morphologically precise statistical data. In routine investigations it is not as a roule necessary. Subarachnoid space scintiscanning should be carried through as an additional test only in cases of internal hydrocephalus or where symptoms suggest a communicating hydrocephalus. After osteoclastic craniotomy, the formation of an internal hydrocephalus is more frequent. In such cases cerebrospinal fluid scintiscanning should be more frequently considered. Shunt operations should not be carried through unless both investigations have ended up with definite results. If differential diagnosis, after a corresponding result of computerized tomography, suggests cerebral atrophy, subarachnoid space scintiscanning is the appropriate method to check the communication of this defect with the liquor-filled spaces and, were necessary, confirm the diagnosis. (orig./MG) [de

  18. Current Concepts for Genital Herpes Simplex Virus Infection: Diagnostics and Pathogenesis of Genital Tract Shedding.

    Science.gov (United States)

    Johnston, Christine; Corey, Lawrence

    2016-01-01

    Herpes simplex virus 2 (HSV-2) is a DNA virus that is efficiently transmitted through intimate genital tract contact and causes persistent infection that cannot be eliminated. HSV-2 may cause frequent, symptomatic self-limited genital ulcers, but in most persons infection is subclinical. However, recent studies have demonstrated that the virus is frequently shed from genital surfaces even in the absence of signs or symptoms of clinical disease and that the virus can be transmitted during these periods of shedding. Furthermore, HSV-2 shedding is detected throughout the genital tract and may be associated with genital tract inflammation, which likely contributes to increased risk of HIV acquisition. This review focuses on HSV diagnostics, as well as what we have learned about the importance of frequent genital HSV shedding for (i) HSV transmission and (ii) genital tract inflammation, as well as (iii) the impact of HSV-2 infection on HIV acquisition and transmission. We conclude with discussion of future areas of research to push the field forward. Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  19. Current Concepts for Genital Herpes Simplex Virus Infection: Diagnostics and Pathogenesis of Genital Tract Shedding

    Science.gov (United States)

    Corey, Lawrence

    2015-01-01

    SUMMARY Herpes simplex virus 2 (HSV-2) is a DNA virus that is efficiently transmitted through intimate genital tract contact and causes persistent infection that cannot be eliminated. HSV-2 may cause frequent, symptomatic self-limited genital ulcers, but in most persons infection is subclinical. However, recent studies have demonstrated that the virus is frequently shed from genital surfaces even in the absence of signs or symptoms of clinical disease and that the virus can be transmitted during these periods of shedding. Furthermore, HSV-2 shedding is detected throughout the genital tract and may be associated with genital tract inflammation, which likely contributes to increased risk of HIV acquisition. This review focuses on HSV diagnostics, as well as what we have learned about the importance of frequent genital HSV shedding for (i) HSV transmission and (ii) genital tract inflammation, as well as (iii) the impact of HSV-2 infection on HIV acquisition and transmission. We conclude with discussion of future areas of research to push the field forward. PMID:26561565

  20. Maximum Bandwidth Enhancement of Current Mirror using Series-Resistor and Dynamic Body Bias Technique

    Directory of Open Access Journals (Sweden)

    V. Niranjan

    2014-09-01

    Full Text Available This paper introduces a new approach for enhancing the bandwidth of a low voltage CMOS current mirror. The proposed approach is based on utilizing body effect in a MOS transistor by connecting its gate and bulk terminals together for signal input. This results in boosting the effective transconductance of MOS transistor along with reduction of the threshold voltage. The proposed approach does not affect the DC gain of the current mirror. We demonstrate that the proposed approach features compatibility with widely used series-resistor technique for enhancing the current mirror bandwidth and both techniques have been employed simultaneously for maximum bandwidth enhancement. An important consequence of using both techniques simultaneously is the reduction of the series-resistor value for achieving the same bandwidth. This reduction in value is very attractive because a smaller resistor results in smaller chip area and less noise. PSpice simulation results using 180 nm CMOS technology from TSMC are included to prove the unique results. The proposed current mirror operates at 1Volt consuming only 102 µW and maximum bandwidth extension ratio of 1.85 has been obtained using the proposed approach. Simulation results are in good agreement with analytical predictions.

  1. Diagnostics of flexible workpiece using acoustic emission, acceleration and eddy current sensors in milling operation

    Science.gov (United States)

    Filippov, A. V.; Tarasov, S. Yu.; Filippova, E. O.; Chazov, P. A.; Shamarin, N. N.; Podgornykh, O. A.

    2016-11-01

    Monitoring of the edge clamped workpiece deflection during milling has been carried our using acoustic emission, accelerometer and eddy current sensors. Such a monitoring is necessary in precision machining of vital parts used in air-space engineering where a majority of them made by milling. The applicability of the AE, accelerometers and eddy current sensors has been discussed together with the analysis of measurement errors. The appropriate sensor installation diagram has been proposed for measuring the workpiece elastic deflection exerted by the cutting force.

  2. Schistosomiasis in the Amazon region: is the current diagnostic strategy still appropriate?

    OpenAIRE

    Sousa, Sergei Rodrigo Magalhães de; Carvalho, Alessandra de Queiroz; Cardoso, Joyce Favacho Nogueira; Coelho, Paulo Marcos Zech; Geiger, Stefan Michael; Enk, Martin Johannes

    2017-01-01

    Abstract INTRODUCTION: This study analyzed the performance of the Kato Katz technique in detecting intestinal schistosomiasis in the State of Pará. METHODS: Of three stool samples provided by each of 380 participants, a total of 16 Kato Katz slides were examined to define the reference value (RV) of positives for comparisons. RESULTS: The RV revealed 37 (9.7%) infected participants in contrast to 10 (2.6%) according to a single slide. CONCLUSIONS: This significant underestimation of t...

  3. Using technique vibration diagnostics for assessing the quality of power transmission line supports repairs

    Directory of Open Access Journals (Sweden)

    Cherpakov Aleksander

    2017-01-01

    Full Text Available The considered method for assessing the quality of the repair work to restore the rack supports of transmission lines is based on the method of vibration diagnostics. Power transmission line supports with a symmetrical destruction of the protective layer of concrete in the ground in violation of the construction section were chosen as an object. Finite element modelling package Ansys was used in assessing the quality of repair work. The example of evaluating the quality of repair using the relative adhesion defective area design criteria in the analysis of natural vibration frequencies is given.

  4. Current status on techniques for determining paleo-temperature using geothermometer

    International Nuclear Information System (INIS)

    Kanazawa, Sunao; Oikawa, Teruki; Umeda, Koji; Tomiyama, Shingo

    2005-01-01

    Development of the research technologies for geotectonic events has been carried out to evaluate the long-term stability of geological environment. In terms of the effects of geothermal activity, it is necessary to estimate the geothermal regime and thermal history on any given site. This paper describes the current status on techniques for determining paleo-temperature using geothermometer, and presents a concept of the systematic research techniques. The application of geothermometer, especially thermochronology, has been effective in the studies on the cooling history of geological body and the paleo-geothermal structure at depth. (author)

  5. Intercomparison of techniques for inspection and diagnostics of heavy water reactor pressure tubes: Flaw detection and characterization [Phase 1

    International Nuclear Information System (INIS)

    2006-05-01

    Nuclear power plants with heavy water reactors (HWRs) comprise nine percent of today's operating nuclear units, and more are under construction. Efficient and accurate inspection and diagnostic techniques for various reactor components and systems are an important factor in assuring reliable and safe plant operation. To foster international collaboration in the efficient and safe use of nuclear power, the IAEA conducted a Coordinated Research Programme (CRP) on Inter-comparison of Techniques for HWR Pressure Tube Inspection and Diagnostics. This CRP was carried out within the frame of the IAEA Department of Nuclear Energy's Technical Working Group on Advanced Technologies for HWRs (the TWG-HWR). The TWG-HWR is a group of experts nominated by their governments and designated by the IAEA to provide advice and to support implementation of the IAEA's project on advanced technologies for HWRs. The objective of the CRP was to inter-compare non-destructive inspection and diagnostic techniques, in use and being developed, for structural integrity assessment of HWR pressure tubes. During the first phase of this CRP, participants have investigated the capability of different techniques to detect and characterize flaws. During the second phase of this CRP, participants collaborated to detect and characterize hydride blisters and to determine the hydrogen concentration in Zirconium alloys. The intent was to identify the most effective pressure tube inspection and diagnostic methods, and to identify further development needs. The organizations that have participated in this CRP are: - The Comision Nacional de Energia Atomica (CNEA), Argentina; - Atomic Energy of Canada Ltd. (AECL); Chalk River Laboratories (CRL), Canada; - The Research Institute of Nuclear Power Operations (RINPO), China National Nuclear Corporation (CNNC), China; - Bhabha Atomic Research Centre (BARC), India; - The Korea Electric Power Research Institute (KEPRI), Republic of Korea; - The Korea Atomic Energy

  6. Pocket book on setting techniques for medical imaging. X-ray diagnostics, angiography, CT, MRT. 4. rev. and enl. ed.; Taschenatlas Einstelltechnik. Roentgendiagnostik, Angiografie, CT, MRT

    Energy Technology Data Exchange (ETDEWEB)

    Moeller, Torsten B.; Reif, Emil [Caritas-Krankenhaus, Dillingen/Saar (Germany)

    2009-07-01

    The pocketbook on setting techniques for medical imaging is concerned with the problem to prepare appropriate images for diagnostic purposes using modern high-technology instruments like x-ray diagnostics, angiography, computerized tomography and magnetic resonance tomography. The following issues are covered: Head, spinal column, upper extremities, lower extremities, thorax, gastrointestinal tract, intravenous organ examination, angiography, computerized tomography, NMR imaging.

  7. Diagnostic and corrective procedures for TL analysis using the pre-dose technique

    International Nuclear Information System (INIS)

    Haskell, E.H.

    1985-01-01

    The high sensitivity of the pre-dose TL technique using fired quartz grains with relatively low doses makes it the only TL technique that is generally suitable for retrospective environmental dosimetry. The use of this technique for dose measurements of less than 0.2 Gy has been the focus of research at the Utah laboratory, while the extension of the useful range of the pre-dose technique to doses in excess of 5 Gy has been the aim of the Durham laboratory. Certain characteristics of the pre-dose phenomenon, if not properly diagnosed, can lead to erroneous dose estimates at both extremes. This paper describes the procedures used at both laboratories to diagnose such problems and recently developed methods for their circumvention. (author)

  8. A Roadmap of Risk Diagnostic Methods: Developing an Integrated View of Risk Identification and Analysis Techniques

    National Research Council Canada - National Science Library

    Williams, Ray; Ambrose, Kate; Bentrem, Laura

    2004-01-01

    ...), which is envisioned to be a comprehensive reference tool for risk identification and analysis (RI AND A) techniques. Program Managers (PMs) responsible for developing or acquiring software-intensive systems typically identify risks in different ways...

  9. Optimization of Antenna Current Feeding for the Alfvén Eigenmodes Active Diagnostic System of JET

    Science.gov (United States)

    Albarracin Manrique, Marcos A.; Ruchko, L.; Pires, C. J. A.; Galvão, R. M. O.; Elfimov, A. G.

    2018-04-01

    The possibility of exploring proper phasing of the feeding currents in the existing antenna of the Alfvén Eigenmodes Active Diagnostic system of JET, to excite pure toroidal spectra of Toroidal Alfvén Eigenmodes, is numerically investigated. Special attention is given to the actual perturbed fields excited in the plasma, which are calculated self-consistently using the antenna version of the CASTOR code. It is found that due to the close spacing of the JET antenna modules and quasi degeneracy of modes with medium to high values of the toroidal mode number n, although a proper choice of the phasing of the feeding currents of the antenna modules indeed leads to an increase of the perturbed fields of the selected mode, modes with nearby values of n are also excited with large amplitudes, so that a scheme to proper select the detected modes remains necessary. A scheme using different antenna position distribution is proposed to achieve successful optimization.

  10. Do Anesthetic Techniques Influence the Threshold for Glomerular Capillary Hemorrhage Induced in Rats by Contrast-Enhanced Diagnostic Ultrasound?

    Science.gov (United States)

    Miller, Douglas L; Lu, Xiaofang; Fabiilli, Mario; Dou, Chunyan

    2016-02-01

    Glomerular capillary hemorrhage can be induced by ultrasonic cavitation during contrast-enhanced diagnostic ultrasound (US) exposure, an important nonthermal US bioeffect. Recent studies of pulmonary US exposure have shown that thresholds for another nonthermal bioeffect of US, pulmonary capillary hemorrhage, is strongly influenced by whether xylazine is included in the specific anesthetic technique. The objective of this study was to determine the influence of xylazine on contrast-enhanced diagnostic US-induced glomerular capillary hemorrhage. In this study, anesthesia with ketamine only was compared to ketamine plus xylazine for induction of glomerular capillary hemorrhage in rats by 1.6-MHz intermittent diagnostic US with a microsphere contrast agent (similar to Definity; Lantheus Medical Imaging, Inc, North Billerica, MA). Glomerular capillary hemorrhage was measured as a percentage of glomeruli with hemorrhage found in histologic sections for groups of rats scanned at different peak rarefactional pressure amplitudes. There was a significant difference between the magnitude of the glomerular capillary hemorrhage between the anesthetics at 2.3 MPa, with 45.6% hemorrhage for ketamine only, increasing to 63.2% hemorrhage for ketamine plus xylazine (P Ultrasound in Medicine.

  11. An Eddy Current Testing Platform System for Pipe Defect Inspection Based on an Optimized Eddy Current Technique Probe Design

    Science.gov (United States)

    Rifai, Damhuji; Abdalla, Ahmed N.; Razali, Ramdan; Ali, Kharudin; Faraj, Moneer A.

    2017-01-01

    The use of the eddy current technique (ECT) for the non-destructive testing of conducting materials has become increasingly important in the past few years. The use of the non-destructive ECT plays a key role in the ensuring the safety and integrity of the large industrial structures such as oil and gas pipelines. This paper introduce a novel ECT probe design integrated with the distributed ECT inspection system (DSECT) use for crack inspection on inner ferromagnetic pipes. The system consists of an array of giant magneto-resistive (GMR) sensors, a pneumatic system, a rotating magnetic field excitation source and a host PC acting as the data analysis center. Probe design parameters, namely probe diameter, an excitation coil and the number of GMR sensors in the array sensor is optimized using numerical optimization based on the desirability approach. The main benefits of DSECT can be seen in terms of its modularity and flexibility for the use of different types of magnetic transducers/sensors, and signals of a different nature with either digital or analog outputs, making it suited for the ECT probe design using an array of GMR magnetic sensors. A real-time application of the DSECT distributed system for ECT inspection can be exploited for the inspection of 70 mm carbon steel pipe. In order to predict the axial and circumference defect detection, a mathematical model is developed based on the technique known as response surface methodology (RSM). The inspection results of a carbon steel pipe sample with artificial defects indicate that the system design is highly efficient. PMID:28335399

  12. FORTRAN programs for transient eddy current calculations using a perturbation-polynomial expansion technique

    International Nuclear Information System (INIS)

    Carpenter, K.H.

    1976-11-01

    A description is given of FORTRAN programs for transient eddy current calculations in thin, non-magnetic conductors using a perturbation-polynomial expansion technique. Basic equations are presented as well as flow charts for the programs implementing them. The implementation is in two steps--a batch program to produce an intermediate data file and interactive programs to produce graphical output. FORTRAN source listings are included for all program elements, and sample inputs and outputs are given for the major programs

  13. Current techniques for visualizing RNA in cells [version 1; referees: 2 approved

    Directory of Open Access Journals (Sweden)

    Lilith V.J.C. Mannack

    2016-04-01

    Full Text Available Labeling RNA is of utmost interest, particularly in living cells, and thus RNA imaging is an emerging field. There are numerous methods relying on different concepts ranging from hybridization-based probes, over RNA-binding proteins to chemo-enzymatic modification of RNA. These methods have different benefits and limitations. This review aims to outline the current state-of-the-art techniques and point out their benefits and limitations.

  14. Advantages and Limitations of Current Imaging Techniques for Characterizing Liposome Morphology

    Directory of Open Access Journals (Sweden)

    Annie-Louise Robson

    2018-02-01

    Full Text Available There are currently a number of imaging techniques available for evaluating the morphology of liposomes and other nanoparticles, with each having its own advantages and disadvantages that should be considered when interpreting data. Controlling and validating the morphology of nanoparticles is of key importance for the effective clinical translation of liposomal formulations. There are a number of physical characteristics of liposomes that determine their in vivo behavior, including size, surface characteristics, lamellarity, and homogeneity. Despite the great importance of the morphology of nanoparticles, it is generally not well-characterized and is difficult to control. Appropriate imaging techniques provide important details regarding the morphological characteristics of nanoparticles, and should be used in conjunction with other methods to assess physicochemical parameters. In this review, we will discuss the advantages and limitations of available imaging techniques used to evaluate liposomal formulations.

  15. Current status on detail design and fabrication techniques development of ITER blanket shield block in Korea

    International Nuclear Information System (INIS)

    Kim, Duck Hoi; Cho, Seungyon; Ahn, Mu-Young; Lee, Eun-Seok; Jung, Ki Jung

    2007-01-01

    The allocation of components and systems to be delivered to ITER on an in-kind basis, was agreed between the ITER Parties. Among parties, Korea agreed to procure inboard blanket modules 1, 2 and 6, which consists of FW and shield block. Regarding shield block the detail design and Fabrication techniques development have been undertaken in Korea. Especially manufacturing feasibility study on shield block had been performed and some technical issues for the fabrication were selected. Based on these results, fabrication techniques using EB welding are being developed. Meanwhile, the detail design of inboard standard module has been carried out. The optimization of flow driver design to improve the cooling performance was executed. And, thermo-hydraulic analysis on half block of inboard standard module was performed. In this study, current status and some results from Fabrication techniques development on ITER blanket shield block are described. The detail design activity and results on shield block are also introduced herein. (orig.)

  16. A Novel Sliding Mode Control Technique for Indirect Current Controlled Active Power Filter

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    2012-01-01

    Full Text Available A novel sliding mode control (SMC method for indirect current controlled three-phase parallel active power filter is presented in this paper. There are two designed closed loops in the system: one is the DC voltage controlling loop and the other is the reference current tracking loop. The first loop with a PI regulator is used to control the DC voltage approximating to the given voltage of capacitor, and the output of PI regulator through a low-pass filter is applied as the input of the power supply reference currents. The second loop implements the tracking of the reference currents using integral sliding mode controller, which can improve the harmonic treating performance. Compared with the direct current control technique, it is convenient to be implemented with digital signal processing system because of simpler system structure and better harmonic treating property. Simulation results verify that the generated reference currents have the same amplitude with the load currents, demonstrating the superior harmonic compensating effects with the proposed shunt active power filter compared with the hysteresis method.

  17. Eddy current technique for detecting and sizing surface cracks in steel components

    International Nuclear Information System (INIS)

    Cecco, V.S.; Carter, J.R.; Sullivan, S.P.

    1995-01-01

    Cracking has occurred in pressure vessel nozzles and girth welds due to thermal fatigue. Pipe welds, welds in support structures, and welds in reactor vault liner panels in nuclear facilities have failed because of cracks. Cracking can also occur in turbine rotor bore surfaces due to high cycle fatigue. Dye penetrant, magnetic particle and other surface NDT methods are used to detect cracks but cannot be used for depth sizing. Crack depth can be measured with various NDT methods such as ultrasonic time-of-flight diffraction (TOFD), potential drop, and eddy current. The TOFD technique can be difficult to implement on nozzle welds and is best suited for sizing deep cracks (>5 mm). The conventional eddy current method is easy to implement, but crack sizing is normally limited to shallow cracks ( 2 mm) cracks. Eddy current testing (ET) techniques are readily amenable to remote/automatic inspections. These new probes could augment present magnetic particle (MT) and dye penetrant (PT) testing through provision of reliable defect depth information. Reliable crack sizing permits identification of critical cracks for plant life extension and licensing purposes. In addition, performing PT and MT generates low level radioactive waste in some inspection applications in nuclear facilities. Replacing these techniques with ET for some components will eliminate some of this radioactive waste. (author)

  18. Development of reactor accident diagnostic system DISKET using knowledge engineering technique

    International Nuclear Information System (INIS)

    Yokobayashi, Masao; Yoshida, Kazuo; Kohsaka, Atsuo; Yamamoto, Minoru.

    1986-01-01

    An accident diagnostic system DISKET has been developed to identify the cause and the type of an abnormal transient of a nuclear power plant. The system is based on the knowledge engineering (KE) and consists of an inference engine IERIAS and a knowledge base. The main features of DISKET are the following : (1) Time-varying characteristics of transients can be treated. (2) Knowledge base can be divided into several knowledge units to handle a lot of rules effectively. (3) Programming language UTILISP, which is a dialect of LISP, is used to manipulate symbolic data effectively. For the verification of DISKET, performance tests have been conducted for several types of accidents. The knowledge base used in the tests was generated from the data of various types of transients produced by a PWR plant simulator. The results of verification studies showed a good applicability of DISKET to reactor accident diagnosis. (author)

  19. Diagnostic prénatal: quelles sont les techniques actuelles et futures ? (flyer)

    CERN Multimedia

    2002-01-01

    La majorité des bébés qui viennent au monde ne présentent pas d'anomalies particulières. Cependant, il faut savoir qu'environ 1 foetus 170 présente une anomalie chromosomique (défaut de la structure ou du nombre de chromosomes) qui va peser plus ou moins lourdement sur sa vie future et 1 foetus sur 100 présente une maladie génique due à un changement dans un gène. Le diagnostic prénatal a connu et connaît une formidable expansion grâce aux progrès technologiques en génétique et imagerie foetale.

  20. The integration of novel diagnostics techniques for multi-scale monitoring of large civil infrastructures

    Directory of Open Access Journals (Sweden)

    F. Soldovieri

    2008-11-01

    Full Text Available In the recent years, structural monitoring of large infrastructures (buildings, dams, bridges or more generally man-made structures has raised an increased attention due to the growing interest about safety and security issues and risk assessment through early detection. In this framework, aim of the paper is to introduce a new integrated approach which combines two sensing techniques acting on different spatial and temporal scales. The first one is a distributed optic fiber sensor based on the Brillouin scattering phenomenon, which allows a spatially and temporally continuous monitoring of the structure with a "low" spatial resolution (meter. The second technique is based on the use of Ground Penetrating Radar (GPR, which can provide detailed images of the inner status of the structure (with a spatial resolution less then tens centimetres, but does not allow a temporal continuous monitoring. The paper describes the features of these two techniques and provides experimental results concerning preliminary test cases.

  1. Current and capacitance measurements as a fast diagnostic tool for evaluation of semiconductor parameters

    CERN Document Server

    Kemmer, J; Krause, N; Krieglmeyer, C; Yang Yi

    2000-01-01

    A fast qualitative method is described for evaluation of semiconductor parameters by analyzing both the capacitance/voltage (C/V) and current/voltage (I/V) characteristics of pn- or Schottky-diodes, which are fabricated on the material under investigation. The method is applied for measurement of recombination and generation lifetimes of minority charge carriers and for determination of doping profiles and distribution of active generation/recombination (G/R) centers after irradiation with Am-alpha particles and deep phosphorus implantation. Measurements on epitaxial silicon result in doping profiles and distributions of active impurities within the epi-layer.

  2. Risk estimation in association with diagnostic techniques in the nuclear medicine service of the Camaguey Ciego de Avila Territory

    International Nuclear Information System (INIS)

    Barrerras, C.A.; Brigido, F.O.; Naranjo, L.A.; Lasserra, S.O.; Hernandez Garcia, J.

    1999-01-01

    The nuclear medicine service at the Maria Curie Oncological Hospital, Camaguey, has experience of over three decades in using radiofarmaceutical imaging agents for diagnosis. Although the clinical risk associated with these techniques is negligible, it is necessary to evaluate the effective dose administered to the patient due to the introduction of radioactive substances into the body. The study of the dose administered to the patient provides useful data for evaluating the detriment associated with this medical practice, its subsequently optimization and consequently, for minimizing the stochastic effects on the patient. The aim of our paper is to study the collective effective dose administered by nuclear medicine service to Camaguey and Ciego de Avila population from 1995 to 1998 and the relative contribution to the total annual effective collective dose of the different diagnostic examinations. The studies were conducted on the basis of statistics from nuclear medicine examinations given to a population of 1102353 inhabitants since 1995. The results show that the nuclear medicine techniques of neck examinations with 1168.8 Sv man (1.11 Sv/expl), thyroid explorations with 119.6 Sv man (55.5 mSv/expl) and iodide uptake with 113.7 Sv man (14.0 mSv/expl) are the main techniques implicated in the relative contribution to the total annual effective collective dose of 1419.5 Sv man. The risk estimation in association with diagnostic techniques in the nuclear medicine service studied is globally low (total detriment: 103.6 as a result of 16232 explorations), similar to other published data

  3. Critical evaluation of fine needle aspiration cytology as a diagnostic technique in bone tumors and tumor-like lesions.

    Science.gov (United States)

    Chakrabarti, Sudipta; Datta, Alok Sobhan; Hira, Michael

    2012-01-01

    Though open surgical biopsy is the procedure of choice for the diagnosis of bone tumors, many disadvantages are associated with this approach. The present study was undertaken to evaluate the role of fine needle aspiration cytology (FNAC) as a diagnostic tool in cases of bony tumors and tumor-like lesions which may be conducted in centers where facilities for surgical biopsies are inadequate. The study population consisted of 51 cases presenting with a skeletal mass. After clinical evaluation, radiological correlation was done to assess the nature and extent of each lesion. Fine needle aspiration was performed aseptically and smears were prepared. Patients subsequently underwent open surgical biopsy and tissue samples were obtained for histopathological examination. Standard statistical methods were applied for analysis of data. Adequate material was not obtained even after repeated aspiration in seven cases, six of which were benign. Among the remaining 44 cases, diagnosis of malignancy was correctly provided in 28 (93.3%) out of 30 cases and categorical diagnosis in 20 (66.67%). Interpretation of cytology was more difficult in cases of benign and tumor-like lesions, with a categorical opinion only possible in seven (50%) cases. Statistical analysis showed FNAC with malignant tumors to have high sensitivity (93.3%), specificity (92.9%) and positive predictive value of 96.6%, whereas the negative predictive value was 86.7%. FNAC should be included in the diagnostic workup of a skeletal tumor because of its simplicity and reliability. However, a definitive pathologic diagnosis heavily depends on compatible clinical and radiologic features which can only be accomplished by teamwork. The cytological technique applied in this study could detect many bone tumors and tumor-like conditions and appears particularly suitable as a diagnostic technique for rural regions of India as other developing countries.

  4. Diagnostic technique for measuring fusion reaction rate for inertial confinement fusion experiments at Shen Guang-III prototype laser facility

    International Nuclear Information System (INIS)

    Wang Feng; Peng Xiao-Shi; Liu Shen-Ye; Xu Tao; Kang Dong-Guo

    2013-01-01

    A study is conducted using a two-dimensional simulation program (Lared-s) with the goal of developing a technique to evaluate the effect of Rayleigh-Taylor growth in a neutron fusion reaction region. Two peaks of fusion reaction rate are simulated by using a two-dimensional simulation program (Lared-s) and confirmed by the experimental results. A neutron temporal diagnostic (NTD) system is developed with a high temporal resolution of ∼ 30 ps at the Shen Guang-III (SG-III) prototype laser facility in China, to measure the fusion reaction rate history. With the shape of neutron reaction rate curve and the spherical harmonic function in this paper, the degree of Rayleigh-Taylor growth and the main source of the neutron yield in our experiment can be estimated qualitatively. This technique, including the diagnostic system and the simulation program, may provide important information for obtaining a higher neutron yield in implosion experiments of inertial confinement fusion

  5. A thermal technique for local ultrasound intensity measurement: part 2. Application to exposimetry on a medical diagnostic device

    International Nuclear Information System (INIS)

    Wilkens, V

    2010-01-01

    Acoustic output measurements on medical ultrasound equipment are usually performed using radiation force balances to determine the output power and using hydrophones to determine pressure and intensity parameters. The local temporal-average ultrasound intensity can be measured alternatively by thermal sensors. The technique was described and prototype sensors were characterized in a preceding paper. Here, the application of such a thermal intensity sensor to the output beam characterization of a typical medical diagnostic device is described. Two transducers, a 7.5 MHz linear array and a 3.5 MHz convex array were investigated in different operating modes. For comparison, hydrophone measurements were also performed. If the spatial averaging effect is taken into account, good agreement is found between both measurement methods. The maximum deviations of the spatial-peak temporal-average intensities I SPTA obtained with the thermal sensor from the corresponding hydrophone-based results were below 12%. The simple thermal technique offers advantages for intensity measurements especially in the case of scanning and combined modes of the diagnostic device, where the synchronization between hydrophone measurements and the complex pulse emission pattern can be difficult

  6. RF power diagnostics and control on the DIII-D, 4 MW 30--120 MHz fast wave current drive system (FWCD)

    International Nuclear Information System (INIS)

    Ferguson, S.W.; Allen, J.C.; Callis, R.W.; Cary, W.P.; Harris, T.E.

    1995-10-01

    The Fast Wave Current Drive System uses three 2 MW transmitters to drive three antennas inside the DIII-D vacuum vessel. This paper describes the diagnostics for this system. The diagnostics associated with the General Atomics Fast Wave Current Drive System allow the system tuning to be analyzed and modified on a between shot basis. The transmitters can be exactly tuned to match the plasma with only one tuning shot into the plasma. This facilitates maximum rf power utilization

  7. Current antimicrobial sensitivity pattern of typhoidal salmonellae in a referral diagnostic centre

    Directory of Open Access Journals (Sweden)

    Umer Shujat

    2016-03-01

    Full Text Available Background: Infections caused by typhoidal salmonellae are an important public health concern in Pakistan. Inappropriate and injudicious use of fluoroquinolones has reduced their efficacy due to development of high level resistance. Aim: To ascertain the current susceptibility pattern of typhoidal salmonellae thus guiding the physicians for better management of typhoid patients.Materials and Methods: A study was conducted at our institution from January 2012 through December 2013 to investigate current susceptibility pattern of typhoidal salmonellae. Results: Out of 200 isolates, 107 (53.5% were identified as Salmonella Typhi and 93 (46.5% as Salmonella Paratyphi A. Sensitivities of Salmonella Typhi were as follows: ampicillin (48.6%, chloramphenicol (45.8%, co-trimoxazole (40.1%, ciprofloxacin (11.2%. Sensitivities of Salmonella Paratyphi A were: ampicillin (80.6%, chloramphenicol (89.2%, co-trimoxazole (90.3%, and ciprofloxacin (16.1%. No resistance was detected against third generation cephalosporins. Conclusions: Typhoidal salmonellae are still entirely susceptible to third generation cephalosporins in our setting. Marked rise in resistance to fluoroquinolones has reduced their empirical usage. Sensitivity of Salmonella Paratyphi A to conventional antityphoid drugs was encouraging.

  8. A new circuit technique for reduced leakage current in Deep Submicron CMOS technologies

    Directory of Open Access Journals (Sweden)

    A. Schmitz

    2005-01-01

    Full Text Available Modern CMOS processes in the Deep Submicron regime are restricted to supply voltages below 2 volts and further to account for the transistors' field strength limitations and to reduce the power per logic gate. To maintain the high switching performance, the threshold voltage must be scaled according with the supply voltage. However, this leads to an increased subthreshold current of the transistors in standby mode (VGS=0. Another source of leakage is gate current, which becomes significant for gate oxides of 3nm and below. We propose a Self-Biasing Virtual Rails (SBVR - CMOS technique which acts like an adaptive local supply voltage in case of standby mode. Most important sources of leakage currents are reduced by this technique. Moreover, SBVR-CMOS is capable of conserving stored information in sleep mode, which is vital for memory circuits. Memories are exposed to radiation causing soft errors. This well-known problem becomes even worse in standby mode of typical SRAMs, that have low driving performance to withstand alpha particle hits. In this paper, a 16-transistor SRAM cell is proposed, which combines the advantage of extremely low leakage currents with a very high soft error stability.

  9. Current status of molecular biological techniques for plant breeding in the Republic of Korea

    Energy Technology Data Exchange (ETDEWEB)

    Sohn, Seong-Han; Lee, Si-Myung; Park, Bum-Seok; Yun, In-Sun; Goo, Doe-Hoe; Kim, Seok-Dong [Rural Development Administration, National Institute of Agricultural Science and Technology, Suwon (Korea)

    2002-02-01

    Classical plant breeding has played an important role in developing new varieties in current agriculture. For decades, the technique of cross-pollination has been popular for breeding in cereal and horticultural crops to introduce special traits. However, recently the molecular techniques get widely accepted as an alternative tool in both introducing a useful trait for developing the new cultivars and investigating the characteristics of a trait in plant, like the identification of a gene. Using the advanced molecular technique, several genetically modified (GM) crops (e.g., Roundup Ready Soybean, YieldGard, LibertyLink etc.) became commercially cultivated and appeared in the global market since 1996. The GM crops, commercially available at the moment, could be regarded as successful achievements in history of crop breeding conferring the specific gene into economically valuable crops to make them better. Along with such achievements, on the other hand these new crops have also caused the controversial debate on the safety of GM crops as human consumption and environmental release as well. Nevertheless, molecular techniques are widespread and popular in both investigating the basic science of plant biology and breeding new varieties compared to their conventional counterparts. Thus, the Department of Bioresources at the National Institute of Agricultural Science and Technology (NIAST) has been using the molecular biological techniques as a complimentary tool for the improvement of crop varieties for almost two decades. (author)

  10. An Experimental Technique for Structural Diagnostic Based on Laser Vibrometry and Neural Networks

    Directory of Open Access Journals (Sweden)

    Paolo Castellini

    2000-01-01

    Full Text Available In recent years damage detection techniques based on vibration data have been largely investigated with promising results for many applications. In particular, several attempts have been made to determine which kind of data should be extracted for damage monitoring.

  11. A Diagnostic Technique for Formulating Market Strategies in Higher Education Based on Relative Competitive Position.

    Science.gov (United States)

    Dolinsky, Arthur L.; Quazi, Hesan A.

    1994-01-01

    Importance-performance analysis, a marketing research technique using analysis of consumer attitudes toward salient product or service attributes, is found useful for colleges and universities in developing marketing strategies, particularly when competition is considered as an important dimension. Data are drawn from a survey of 252 students at 1…

  12. Application of numerical analysis techniques to eddy current testing for steam generator tubes

    International Nuclear Information System (INIS)

    Morimoto, Kazuo; Satake, Koji; Araki, Yasui; Morimura, Koichi; Tanaka, Michio; Shimizu, Naoya; Iwahashi, Yoichi

    1994-01-01

    This paper describes the application of numerical analysis to eddy current testing (ECT) for steam generator tubes. A symmetrical and three-dimensional sinusoidal steady state eddy current analysis code was developed. This code is formulated by future element method-boundary element method coupling techniques, in order not to regenerate the mesh data in the tube domain at every movement of the probe. The calculations were carried out under various conditions including those for various probe types, defect orientations and so on. Compared with the experimental data, it was shown that it is feasible to apply this code to actual use. Furthermore, we have developed a total eddy current analysis system which consists of an ECT calculation code, an automatic mesh generator for analysis, a database and display software for calculated results. ((orig.))

  13. First meeting on the CRP 'standardized high current solid targets for cyclotron production of diagnostic and therapeutic radionuclides'

    International Nuclear Information System (INIS)

    Winkel, P. van den

    2000-01-01

    The Cyclotron Department of the VUB has three groups performing research in the field of target development, production of radionuclides and their application in nuclear medicine. 1. The Physics Group is busy on the optimization of beam parameters, on the determination of cross sections and on neutron spectrometry. 2. The Inorganic Radiochemistry Group performs research on solid target electroplating (Tl, Zn, Cd, Rh ... ), on optimisation of target carrier geometry and cooling and on automated PC-controlled radiochemistry (Tl-201, Ga-67, In-111) and recovery systems and the associated software written in Modula-2 and Visual Basic. 3. The Organic Radiochemistry Group develops new techniques for radiolabelling of organic molecules (fatty acids, neuroleptics, synthetic polypeptides...) useful in diagnostic and therapeutic nuclear medicine. All three groups take part in bulk productions of radionuclides

  14. Molecular methods for pathogen and microbial community detection and characterization: current and potential application in diagnostic microbiology.

    Science.gov (United States)

    Sibley, Christopher D; Peirano, Gisele; Church, Deirdre L

    2012-04-01

    Clinical microbiology laboratories worldwide have historically relied on phenotypic methods (i.e., culture and biochemical tests) for detection, identification and characterization of virulence traits (e.g., antibiotic resistance genes, toxins) of human pathogens. However, limitations to implementation of molecular methods for human infectious diseases testing are being rapidly overcome allowing for the clinical evaluation and implementation of diverse technologies with expanding diagnostic capabilities. The advantages and limitation of molecular techniques including real-time polymerase chain reaction, partial or whole genome sequencing, molecular typing, microarrays, broad-range PCR and multiplexing will be discussed. Finally, terminal restriction fragment length polymorphism (T-RFLP) and deep sequencing are introduced as technologies at the clinical interface with the potential to dramatically enhance our ability to diagnose infectious diseases and better define the epidemiology and microbial ecology of a wide range of complex infections. Copyright © 2012 Elsevier B.V. All rights reserved.

  15. Office hysteroscopic-guided selective tubal chromopertubation: acceptability, feasibility and diagnostic accuracy of this new diagnostic non-invasive technique in infertile women.

    Science.gov (United States)

    Carta, Gaspare; Palermo, Patrizia; Pasquale, Chiara; Conte, Valeria; Pulcinella, Ruggero; Necozione, Stefano; Cofini, Vincenza; Patacchiola, Felice

    2018-06-01

    The aim of this study was to evaluate accuracy, tolerability and side effects of office hysteroscopic-guided chromoperturbations in infertile women without anaesthesia. Forty-nine infertile women underwent the procedure to evaluate tubal patency and the uterine cavity. Women with unilateral or bilateral tubal stenosis at hysteroscopy with chromoperturbation, and women with bilateral tubal patency who did not conceive during the period of six months, underwent laparoscopy with chromoperturbation. The results obtained from hysteroscopy and laparoscopy in the assessment of tubal patency were compared. Sensitivity, specificity, accuracy, positive-predictive value and negative-predictive value were used to describe diagnostic performance. Pain and tolerance were assessed during procedure using a visual analogue scale (VAS). Side effects or late complications and pregnancy rate were also recorded three and six months after the procedure. The specificity was 87.8% (95% CI: 73.80-95.90), sensitivity was 85.7% (95% CI 57.20-98.20), positive and negative predictive values were 70.6% (95% CI: 44.00-89) and 94.7% (95% CI: 82.30-99.40), respectively. Pregnancy rate (PR) within six months after performance of hysteroscopy with chromoperturbation was 27%. Office hysteroscopy-guided selective chromoperturbation in infertile patients is a valid technique to evaluate tubal patency and uterine cavity.

  16. Comparison of radiation delivered by current diagnostic procedures for herniated disc

    International Nuclear Information System (INIS)

    Gasquet, C.; Drouineau, J.; Goubault, F.; Hurmic, A.; Lavigne, B.; Vandermarcq, P.

    1983-01-01

    Three methods are currently employed for the diagnosis of sciatica due to disc lesions: radiculography, spinal phlebography, and computed tomography. Though their indications vary according to the author, it seemed worthwhile to compare radiation delivered by each of them, because of the often young age of the patients. Dosimetric studies using a Rando Phantom enabled calculation of doses to the skin, spinal cord, and gonads. Results indicated that low doses were delivered by the scanner, relatively high doses by spinal phlebography, and intermediate doses by radiculography. These findings suggest that the initial examination preoperatively in cases of simple sciatica due to herniated disc should be a CT scan whenever possible. Phlebography, on the contrary, and particularly in young women, should be used only exceptionally, as a result of the high doses delivered to the ovaries even during technically simple explorations [fr

  17. Procalcitonin as a diagnostic and prognostic marker in diabetic foot infection. A current literature review.

    Science.gov (United States)

    Velissaris, Dimitrios; Pantzaris, Nikolaos-Dimitrios; Platanaki, Christina; Antonopoulou, Nikolina; Gogos, Charalampos

    2018-03-01

    Diabetic foot ulcers (DFUs) are a very common cause of mortality and morbidity. The distinction between infected and non-infected DFU remains a very challenging task for clinicians in everyday practice. Even when infection is documented, the spectrum of diabetic foot infection is wide, ranging from cellulitis and soft tissue infection to osteomyelitis. Procalcitonin (PCT), a well-established sepsis biomarker, has been used in the diagnosis of several infections including osteomyelitis in patients with diabetes mellitus. This review gathers and presents all the relevant data, up until now, regarding the use of PCT as an assessment tool in diabetic patients with foot infection. Current evidence suggests that PCT levels could aid clinicians in distinguishing infected from non-infected DFUs as well as in the distinction between soft tissue infection and bone involvement, but further and larger studies are warranted to confirm these findings.

  18. New Leakage Current Particulate Matter Sensor for On-Board Diagnostics

    Directory of Open Access Journals (Sweden)

    Jiawei Wang

    2016-01-01

    Full Text Available Structure and principle of the new leakage current particulate matter (PM sensor are introduced and further study is performed on the PM sensor with the combination of numerical simulation and bench test. High voltage electrode, conductive shell, and heaters are all built-in. Based on the principle of Venturi tube and maze structure design, this sensor can detect transient PM concentrations. Internal flow field of the sensor and distribution condition of PM inside the sensor are analyzed through gas-solid two-phase flow numerical simulation. The experiment was also carried out on the whole sensor system (including mechanical and electronic circuit part and the output signals were analyzed. The results of simulation and experiment reveal the possibility of PM concentration (mass detection by the sensor.

  19. [Domestic violence: a current issue to take into account in diagnostic imaging].

    Science.gov (United States)

    Santos Corraliza, E; Larrañaga Hernando, G; Neve Lete, I; Sánchez García, A

    2014-01-01

    Domestic violence is currently an issue of great political and social importance. The real incidence of domestic violence is difficult to determine due to the environment where it takes place and the reluctance of victims to report abuse. On the other hand, all types of violence represent an important public health problem. We report the case of a young woman who presented with thromboembolic phenomena at different sites due to domestic violence. We emphasize that it is necessary for radiologists and other healthcare professionals to consider the possibility of domestic violence when establishing the diagnosis. This can be important for determining the incidence of abuse, diminishing its sequela, and help increase its reporting. Copyright © 2011 SERAM. Published by Elsevier Espana. All rights reserved.

  20. Diagnostic reproducibility of hydatidiform moles: ancillary techniques (p57 immunohistochemistry and molecular genotyping) improve morphologic diagnosis.

    Science.gov (United States)

    Vang, Russell; Gupta, Mamta; Wu, Lee-Shu-Fune; Yemelyanova, Anna V; Kurman, Robert J; Murphy, Kathleen M; Descipio, Cheryl; Ronnett, Brigitte M

    2012-03-01

    Distinction of hydatidiform moles (HMs) from nonmolar specimens (NMs) and subclassification of HMs as complete hydatidiform moles (CHMs) and partial hydatidiform moles (PHMs) are important for clinical practice and investigational studies; yet, diagnosis based solely on morphology is affected by interobserver variability. Molecular genotyping can distinguish these entities by discerning androgenetic diploidy, diandric triploidy, and biparental diploidy to diagnose CHMs, PHMs, and NMs, respectively. Eighty genotyped cases (27 CHMs, 27 PHMs, and 26 NMs) were selected from a series of 200 potentially molar specimens previously diagnosed using p57 immunostaining and genotyping. Cases were classified by 3 gynecologic pathologists on the basis of H&E slides (masked to p57 immunostaining and genotyping results) into 1 of 3 categories (CHM, PHM, or NM) during 2 diagnostic rounds; a third round incorporating p57 immunostaining results was also conducted. Consensus diagnoses (those rendered by 2 of 3 pathologists) were determined. Genotyping results were used as the gold standard for assessing diagnostic performance. Sensitivity of a diagnosis of CHM ranged from 59% to 100% for individual pathologists and from 70% to 81% by consensus; specificity ranged from 91% to 96% for individuals and from 94% to 98% by consensus. Sensitivity of a diagnosis of PHM ranged from 56% to 93% for individual pathologists and from 70% to 78% by consensus; specificity ranged from 58% to 92% for individuals and from 74% to 85% by consensus. The percentage of correct classification of all cases by morphology ranged from 55% to 75% for individual pathologists and from 70% to 75% by consensus. The κ values for interobserver agreement ranged from 0.59 to 0.73 (moderate to good) for a diagnosis of CHM, from 0.15 to 0.43 (poor to moderate) for PHM, and from 0.13 to 0.42 (poor to moderate) for NM. The κ values for intraobserver agreement ranged from 0.44 to 0.67 (moderate to good). Addition of the p57

  1. Gel instillation sonohysterography (GIS) and saline contrast sonohysterography (SCSH): comparison of two diagnostic techniques.

    Science.gov (United States)

    Bij de Vaate, A J M; Brölmann, H A M; van der Slikke, J W; Emanuel, M H; Huirne, J A F

    2010-04-01

    To compare gel instillation sonohysterography (GIS) with saline contrast sonohysterography (SCSH) as diagnostic methods for the evaluation of the uterine cavity. A prospective cohort study was performed at the Department of Obstetrics and Gynecology of the VU University Medical Center, Amsterdam, between September 2007 and April 2008. We included 65 women suspected of having an intrauterine abnormality with an indication for SCSH/GIS. First SCSH and subsequently GIS were performed in all women. Distension of the uterine cavity, image quality, visualization of intrauterine abnormalities and pain experienced on a visual analog scale (VAS score) were recorded for both procedures. The mean distension with GIS was 9.0 mm and with SCSH it was 8.5 mm (P = 0.15). The mean image quality, on a scale from 0 to 5, for SCSH was 4.0 and for GIS it was 3.6 (P = 0.01). No difference was found for the visualization of intrauterine abnormalities, and the VAS scores for pain experienced on SCSH and GIS were 1.5 and 1.6, respectively (P = 0.62). The image quality of SCSH is slightly better than that of GIS. This difference is likely to be attributable to the presence of air bubbles in the gel. The small difference in uterine cavity distension in favor of GIS and comparable stable distension during at least 4 min make GIS a suitable alternative for SCSH if air bubbles can be prevented. Copyright 2009 ISUOG. Published by John Wiley & Sons, Ltd.

  2. Thermometric diagnosis of peripheral nerve injuries. Assessment of the diagnostic accuracy of a new practical technique.

    Science.gov (United States)

    Ya'ish, F M M; Cooper, J P; Craigen, M A C

    2007-07-01

    The diagnosis of nerve injury using thermotropic liquid crystal temperature strips was compared blindly and prospectively against operative findings in 36 patients requiring surgical exploration for unilateral upper limb lacerations with suspected nerve injury. Thermotropic liquid crystal strips were applied to affected and non-affected segments in both hands in all subjects. A pilot study showed that a simple unilateral laceration without nerve injury results in a cutaneous temperature difference between limbs, but not within each limb. Thus, for detection of a nerve injury, comparison was made against the unaffected nerve distribution in the same hand. Receiver operating characteristic curve analysis showed that an absolute temperature difference > or = 1.0 degrees C was diagnostic of a nerve injury (area under the curve = 0.985, sensitivity = 100%, specificity = 93.8%). Thermotropic liquid crystal strip assessment is a new, reliable and objective method for the diagnosis of traumatic peripheral nerve injuries. If implemented in the acute setting, it could improve the reliability of clinical assessment and reduce the number of negative surgical explorations.

  3. Use of serological diagnostic techniques in the control and eradication of caprine arthritis encephalitis: an update

    Directory of Open Access Journals (Sweden)

    Jamili Maria Suhet Mussi

    2015-12-01

    Full Text Available Caprine arthritis encephalitis (CAE is a chronic disease caused by a small ruminant lentivirus (SRLV, which causes significant losses in goat breeding. The actual state of animal infection with SRLV is difficult to determine due to a complex pathogenesis of the virus, including factors such as delayed or intermittent seroconversion in serological tests. Several serological techniques are available for disease diagnosis, such as screening or confirmation tests, which are different in sensitivity and specificity. Regarding the choice of the test to be applied, availability of commercial immunoreagents, team training, antigen used, and cost of techniques must be considered. This review presents the serological methods available for use in different stages of CAE control and eradication programs, and management measures to be adopted in conjunction with serological diagnosis of the disease.

  4. Diagnostic of corrosion defects in steam generator tubes using advanced signal processing from Eddy current testing

    International Nuclear Information System (INIS)

    Formigoni, Andre L.; Lopez, Luiz A.N.M.; Ting, Daniel K.S.

    2009-01-01

    Recently, the Brazilian Angra I PWR nuclear power plant went into a programmed shutdown for substitution of its Steam Generator (SG) which life was shortened due to stress corrosion in its tubes. The total cost of investment were around R$724 million. The signals generated during an Eddy-current Testing (ECT) inspection in SG tubes of nuclear plant allows for the localization and dimensioning of defects in the tubes. The defects related with corrosion generate complex signals that are difficult to analyze and are the most common cause in SG replacement in nuclear power plants around the world. The objective of this paper is the development of a methodology that allows for the characterization of corrosion signals by ECT inspections applied in the heat exchangers tubes of SG of a nuclear power plant. In this present work, the aim is to investigate distributed type defects by inducing controlled corrosion in sample tubes of different materials The ECT signals obtained from these samples tubes with corrosion implanted, will be analyzed using Zetec ECT equipment, the MIZ-17ET and its probes. The data acquisition will use a NI PC A/D CARD 700 card and the LabVIEW program. Subsequently, we will apply mathematical tools for signal processing like time windowed Fast Fourier transforms and Wavelets transforms, in MATLAB platform, which will allow effectiveness to remove the noises and to extract representative characteristics for the defect being analyzed. Previously obtained results as well as the proposal for the future work will be presented. (author)

  5. Diagnosis of soil-transmitted helminthiasis in an Amazonic community of Peru using multiple diagnostic techniques.

    Science.gov (United States)

    Machicado, Jorge D; Marcos, Luis A; Tello, Raul; Canales, Marco; Terashima, Angelica; Gotuzzo, Eduardo

    2012-06-01

    An observational descriptive study was conducted in a Shipibo-Conibo/Ese'Eja community of the rainforest in Peru to compare the Kato-Katz method and the spontaneous sedimentation in tube technique (SSTT) for the diagnosis of intestinal parasites as well as to report the prevalence of soil-transmitted helminth (STH) infections in this area. A total of 73 stool samples were collected and analysed by several parasitological techniques, including Kato-Katz, SSTT, modified Baermann technique (MBT), agar plate culture, Harada-Mori culture and the direct smear examination. Kato-Katz and SSTT had the same rate of detection for Ascaris lumbricoides (5%), Trichuris trichiura (5%), hookworm (14%) and Hymenolepis nana (26%). The detection rate for Strongyloides stercoralis larvae was 16% by SSTT and 0% by Kato-Katz, but 18% by agar plate culture and 16% by MBT. The SSTT also had the advantage of detecting multiple intestinal protozoa such as Blastocystis hominis (40%), Giardia intestinalis (29%) and Entamoeba histolytica/E. dispar (16%). The most common intestinal parasites found in this community were B. hominis, G. intestinalis, H. nana, S. stercoralis and hookworm. In conclusion, the SSTT is not inferior to Kato-Katz for the diagnosis of common STH infections but is largely superior for detecting intestinal protozoa and S. stercoralis larvae. Copyright © 2012 Royal Society of Tropical Medicine and Hygiene. Published by Elsevier Ltd. All rights reserved.

  6. Analysis of relaxing laser-induced plasmas by absorption spectroscopy: Toward a new quantitative diagnostic technique

    International Nuclear Information System (INIS)

    Ribiere, M.; Cheron, B.G.

    2010-01-01

    Broad-band near UV absorption spectroscopy was used to analyze atmospheric laser-induced plasmas formed on metallic and refractory targets. When the common emission spectroscopy only provides the density of the radiating atomic excited states, the technique reported in this paper is able to achieve high spatial resolution in the measurement of absolute number densities in expanding laser-induced plasmas. The reliability and the versatility of this technique, which is based on the comparison between results of the numerical integration of the radiative transfer equation and experimental spectra, were tested on different targets. The evolutions in time and space of the absolute population of the plasma species originating from metallic alloys (Al-Mg and Cu-Ni) and refractory materials (C/SiC) were achieved over large time scales. Owing to its accuracy, this absorption technique (that we call 'LIPAS' for Laser Induced Plasma Absorption Spectroscopy) should bring a new and enhanced support to the validation of collisional-radiative models attempting to provide reliable evolutions of laser-induced plasmas.

  7. Current use and acceptability of novel diagnostic tests for active tuberculosis: a worldwide survey

    Directory of Open Access Journals (Sweden)

    Massimo Amicosante

    Full Text Available ABSTRACT Objective: To determine the current use and potential acceptance (by tuberculosis experts worldwide of novel rapid tests for the diagnosis of tuberculosis that are in line with World Health Organization target product profiles. Methods: A multilingual survey was disseminated online between July and November of 2016. Results: A total of 723 individuals from 114 countries responded to the survey. Smear microscopy was the most commonly used rapid tuberculosis test (available to 90.9% of the respondents, followed by molecular assays (available to 70.7%. Only a small proportion of the respondents in middle- and low-income countries had access to interferon-gamma-release assays. Serological and lateral flow immunoassays were used by more than a quarter (25.4% of the respondents. Among the respondents who had access to molecular tests, 46.7% were using the Xpert assay overall, that proportion being higher in lower middle-income countries (55.6% and low-income countries (76.6%. The data also suggest that there was some alignment of pricing for molecular assays. Respondents stated they would accept novel rapid tuberculosis tests if available, including molecular assays (acceptable to 86.0% or biomarker-based serological assays (acceptable to 81.7%. Simple biomarker-based assays were more commonly deemed acceptable in middle- and low-income countries. Conclusions: Second-generation molecular assays have become more widely available in high- and low-resource settings. However, the development of novel rapid tuberculosis tests continues to be considered important by tuberculosis experts. Our data also underscore the need for additional training and education of end users.

  8. Analysis techniques of charging damage studied on three different high-current ion implanters

    Science.gov (United States)

    Felch, S. B.; Larson, L. A.; Current, M. I.; Lindsey, D. W.

    1989-02-01

    One of the Greater Silicon Valley Implant Users' Group's recent activities has been to sponsor a round-robin on charging damage, where identical wafers were implanted on three different state-of-the-art, high-current ion implanters. The devices studied were thin-dielectric (250 Å SiO2), polysilicon-gate MOS capacitors isolated by thick field oxide. The three implanters involved were the Varian/Extrion 160XP, the Eaton/Nova 10-80, and the Applied Materials PI9000. Each implanter vendor was given 48 wafers to implant with 100 keV As+ ions at a dose of 1 × 1016 cm-2. Parameters that were varied include the beam current, electron flood gun current, and chamber pressure. The charge-to-breakdown, breakdown voltage, and leakage current of several devices before anneal have been measured. The results from these tests were inconclusive as to the physical mechanism of charging and as to the effectiveness of techniques to reduce its impact on devices. However, the methodology of this study is discussed in detail to aid in the planning of future experiments. Authors' industrial affiliations: S.B. Felch, Varian Research Center, 611 Hansen Way, Palo Alto, CA 94303, USA; L.A. Larson, National Semiconductor Corp., P.O. Box 58090, Santa Clara, CA 95052-8090, USA; M.I. Current, Applied Materials, 3050 Bowers Ave., Santa Clara, CA 95054, USA; D.W. Lindsey, Eaton/NOVA, 931 Benicia Ave, Sunnyvale, CA 94086, USA.

  9. A 540-[Formula: see text] Duty Controlled RSSI With Current Reusing Technique for Human Body Communication.

    Science.gov (United States)

    Jang, Jaeeun; Lee, Yongsu; Cho, Hyunwoo; Yoo, Hoi-Jun

    2016-08-01

    An ultra-low-power duty controlled received signal strength indicator (RSSI) is implemented for human body communication (HBC) in 180 nm CMOS technology under 1.5 V supply. The proposed RSSI adopted 3 following key features for low-power consumption; 1) current reusing technique (CR-RSSI) with replica bias circuit and calibration unit, 2) duty controller, and 3) reconfigurable gm-boosting LNA. The CR-RSSI utilizes stacked amplifier-rectifier-cell (AR-cell) to reuse the supply current of each blocks. As a result, the power consumption becomes 540 [Formula: see text] with +/-2 dB accuracy and 75 dB dynamic range. The replica bias circuit and calibration unit are adopted to increase the reliability of CR-RSSI. In addition, the duty controller turns off the RSSI when it is not required, and this function leads 70% power reduction. At last, the gm-boosting reconfigurable LNA can adaptively vary its noise and linearity performance with respect to input signal strength. Fro current reusing technique m this feature, we achieve 62% power reduction in the LNA. Thanks to these schemes, compared to the previous works, we can save 70% of power in RSSI and LNA.

  10. CONTROL SYSTEM FOR THE LITHIUM BEAM EDGE PLASMA CURRENT DENSITY DIAGNOSTIC ON THE DIII-D TOKAMAK

    International Nuclear Information System (INIS)

    PEAVY, J.J.; CARY, W.P; THOMAS, D.M; KELLMAN, D.H.; HOYT, D.M; DELAWARE, S.W.; PRONKO, S.G.E.; HARRIS, T.E.

    2004-03-01

    OAK-B135 An edge plasma current density diagnostic employing a neutralized lithium ion beam system has been installed on the DIII-D tokamak. The lithium beam control system is designed around a GE Fanuc 90-30 series PLC and Cimplicity(reg s ign) HMI (Human Machine Interface) software. The control system operates and supervises a collection of commercial and in-house designed high voltage power supplies for beam acceleration and focusing, filament and bias power supplies for ion creation, neutralization, vacuum, triggering, and safety interlocks. This paper provides an overview of the control system, while highlighting innovative aspects including its remote operation, pulsed source heating and pulsed neutralizer heating, optimizing beam regulation, and beam ramping, ending with a discussion of its performance

  11. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    International Nuclear Information System (INIS)

    Sahin, Guelden; Demirtas, Mehmet

    2006-01-01

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established

  12. An overview of MR arthrography with emphasis on the current technique and applicational hints and tips

    Energy Technology Data Exchange (ETDEWEB)

    Sahin, Guelden [Department of Radiology, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)]. E-mail: gsahin@medicine.ankara.edu.tr; Demirtas, Mehmet [Department of Hand Surgery, Faculty of Medicine, Ankara University, Samanpazari, 06100 Ankara (Turkey)

    2006-06-15

    Magnetic resonance (MR) arthrography has been investigated in every major peripheral joint of the body, and has been proven to be effective in determining the integrity of intraarticular ligamentous and fibrocartilaginous structures and in the detection or assessment of osteochondral lesions and loose bodies in selected cases. Several methods could be used to create arthrogram effect during MR imaging, however, direct MR arthrography using diluted gadolinium as the contrast agent is the most commonly used technique and is the most reliable of all. MR arthrography is useful for demonstrating labrocapsular-ligamentous abnormalities and distinguishing partial thickness rotator cuff tears from focal full thickness tears in the shoulder, identifying or excluding recurrent tears following meniscal operations in the knee, demonstrating perforations of the triangular fibrocartilage complex (TFCC) and ligaments in the wrist, showing labral tears in the hip, diagnosing ligament tears in the ankle and identifying osteochondral lesions or loose bodies in any of the aforementioned joints. In this article, an overview of techniques of MR arthrography is provided with emphasis on direct MR arthrography using diluted gadolinium as the contrast agent. The current applications of the technique in major peripheral joints are reviewed, with emphasis given to the shoulder joint where the role of this technique has become well established.

  13. Sensor Fusion Techniques for Phased-Array Eddy Current and Phased-Array Ultrasound Data

    Energy Technology Data Exchange (ETDEWEB)

    Arrowood, Lloyd F. [Y-12 National Security Complex, Oak Ridge, TN (United States)

    2018-03-15

    Sensor (or Data) fusion is the process of integrating multiple data sources to produce more consistent, accurate and comprehensive information than is provided by a single data source. Sensor fusion may also be used to combine multiple signals from a single modality to improve the performance of a particular inspection technique. Industrial nondestructive testing may utilize multiple sensors to acquire inspection data depending upon the object under inspection and the anticipated types of defects that can be identified. Sensor fusion can be performed at various levels of signal abstraction with each having its strengths and weaknesses. A multimodal data fusion strategy first proposed by Heideklang and Shokouhi that combines spatially scattered detection locations to improve detection performance of surface-breaking and near-surface cracks in ferromagnetic metals is shown using a surface inspection example and is then extended for volumetric inspections. Utilizing data acquired from an Olympus Omniscan MX2 from both phased array eddy current and ultrasound probes on test phantoms, single and multilevel fusion techniques are employed to integrate signals from the two modalities. Preliminary results demonstrate how confidence in defect identification and interpretation benefit from sensor fusion techniques. Lastly, techniques for integrating data into radiographic and volumetric imagery from computed tomography are described and results are presented.

  14. New diagnostic and therapeutic techniques in the management of pyogenic liver abscesses

    International Nuclear Information System (INIS)

    Ranson, J.H.C.; Madayag, M.A.; Localio, S.A.; Spencer, F.C.

    1975-01-01

    An unexplained increase in the frequency of pyogenic liver abscesses of unknown etiology has, fortunately, been paralleled by significant advances in diagnostic and therapeutic methods. This report reviews experience with 14 patients operated upon at NYU Medical Center since 1971. Eight cases (57 percent) were cryptogenic. Other abscesses were associated with biliary disease (3); abdominal sepsis (2); and trauma (1). Abscesses were present on hospitalization in 12 patients. Clinical findings included fever (101 to 108 F), 100 percent; leucocytosis, 71 percent; anorexia and vomiting, 50 percent; localized tenderness and hepatomegaly, 50 percent; hypoalbuminemia; 86 percent; hypocholesterolemia, 78 percent; elevated SGOT, 71 percent; and elevated aikaline phosphatase, 43 percent. Technetium hepatic scintiscans showed focal defects in 10 of 12 patients (83 percent), but did not detect multiple abscesses in 2 of these. Hepatic arteriography performed in 10 patients was highly accurate, outlining single abscesses in 6 and multiple abscesses in 4. Furthermore, in one patient a false positive scintiscan was demonstrated by negative arteriography, confirmed by autopsy. In 4 patients, arteriography indicated an abscess in the posterior-superior area of the right hepatic lobe. With precise anatomical localization, a transthoracic approach permitted uncomplicated drainage in each case. This approach provides excellent exposure and direct drainage for abscesses in this area. An additional therapeutic adjunct in two patients, with 4 and 11 abscesses each, was postoperative intraportal infusion of antibiotics through the umbilical vein. Thirteen patients (83 percent) recovered, one dying from pulmonary embolism. Primary hepatic abscesses occur with increasing frequency. The methods described allow more precise preoperative diagnosis and direct surgical drainage

  15. Four-hour processing of clinical/diagnostic specimens for electron microscopy using microwave technique.

    Science.gov (United States)

    Giberson, R T; Demaree, R S; Nordhausen, R W

    1997-01-01

    A protocol for routine 4-hour microwave tissue processing of clinical or other samples for electron microscopy was developed. Specimens are processed by using a temperature-restrictive probe that can be set to automatically cycle the magnetron to maintain any designated temperature restriction (temperature maximum). In addition, specimen processing during fixation is performed in 1.7-ml microcentrifuge tubes followed by subsequent processing in flow-through baskets. Quality control is made possible during each step through the addition of an RS232 port to the microwave, allowing direct connection of the microwave oven to any personal computer. The software provided with the temperature probe enables the user to monitor time and temperature on a real-time basis. Tissue specimens, goat placenta, mouse liver, mouse kidney, and deer esophagus were processed by conventional and microwave techniques in this study. In all instances, the results for the microwave-processed samples were equal to or better than those achieved by routine processing techniques.

  16. Comparison of different diagnostic techniques for the detection of cryptosporidiosis in bovines

    Directory of Open Access Journals (Sweden)

    H. K. M. Rekha

    2016-02-01

    Full Text Available Aim: Aim of the present study was to compare different methods, viz., Sheather’s sugar flotation (SSF, Ziehl-Neelsen (ZN, Kinyoun’s acid-fast method (KAF, safranin-methylene blue staining (SMB, and negative staining techniques such as nigrosin staining, light green staining, and malachite green staining for the detection of Cryptosporidium spp. oocysts in bovines. Materials and Methods: A total of 455 fecal samples from bovines were collected from private, government farms and from the clinical cases presented to Department of Medicine, Veterinary College, Bengaluru. They were subjected for SSF, ZN, KAF, SMB and negative staining methods. Results: Out of 455 animal fecal samples screened 5.71% were found positive for Cryptosporidium spp. oocysts. The species were identified as Cryptosporidium parvum in calves and Cryptosporidium andersoni in adults based on the morphological characterization and micrometry of the oocysts. Conclusions: Of all the techniques, fecal flotation with sheather’s was found to be more specific and sensitive method for the detection of Cryptosporidium spp. oocysts. Among the conventional staining methods, the SMB gives better differentiation between oocysts and yeast. Among the three negative staining methods, malachite green was found sensitive over the other methods.

  17. Sensitivity of diagnostic techniques in determining the prevalence of anuran trypanosomes.

    Science.gov (United States)

    Woo, P T

    1983-01-01

    Two hundred thirty-three leopard frogs (Rana pipiens) from Oshkosh, Wisconsin, USA, were divided into two groups and their blood examined for trypanosomes. In Group I (n = 157), where the blood was examined by the hematocrit centrifuge technique (HCT), 36 (23%) were infected with trypanosomes. Eighteen were infected with Trypanosoma pipientis, 13 with Trypanosoma ranarum, three with Trypanosoma rotatorium and two with mixed infections of T. pipientis and T. ranarum. In Group II (n = 76) the blood was cultured and also examined by HCT and wet mounts. Trypanosomes (T. pipientis and T. ranarum) were detected in 24 frogs (33%) using all three techniques. Eleven T. pipientis were detected by HCT, however none by culture and two by wet mounts. Twelve T. ranarum were detected by culture while only 10 were found by HCT and five by wet mounts. One T. ranarum infection detected by HCT was missed by culture because of bacterial contamination. The HCT was consistently better than wet mount examinations. It is suggested that the HCT be used whenever possible in future trypanosome surveys.

  18. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    International Nuclear Information System (INIS)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg; Farshad, Mazda; Espinosa, Norman; Resnick, Donald

    2013-01-01

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  19. Diagnostic performance of MRI measurements to assess hindfoot malalignment. An assessment of four measurement techniques

    Energy Technology Data Exchange (ETDEWEB)

    Buck, Florian M.; Hoffmann, Adrienne; Mamisch-Saupe, Nadja; Hodler, Juerg [University Hospital Balgrist and University of Zurich, Radiology, Zuerich (Switzerland); Farshad, Mazda; Espinosa, Norman [University Hospital Balgrist and University of Zurich, Department of Orthopaedic Surgery, Zuerich (Switzerland); Resnick, Donald [University of California San Diego, Department of Radiology, San Diego, CA (United States)

    2013-09-15

    To investigate the ability of coronal non-weight-bearing MR images to discriminate between normal and abnormal hindfoot alignment. Three different measurement techniques (calcaneal axis, medial/lateral calcaneal contour) based on weight-bearing hindfoot alignment radiographs were applied in 49 patients (mean, 48 years; range 21-76 years). Three groups of subjects were enrolled: (1) normal hindfoot alignment (0 -10 valgus); (2) abnormal valgus (>10 ); (3) any degree of varus hindfoot alignment. Hindfoot alignment was then measured on coronal MR images using four different measurement techniques (calcaneal axis, medial/lateral calcaneal contour, sustentaculum tangent). ROC analysis was performed to find the MR measurement with the greatest sensitivity and specificity for discrimination between normal and abnormal hindfoot alignment. The most accurate measurement on MR images to detect abnormal hindfoot valgus was the one using the medial calcaneal contour, reaching a sensitivity/specificity of 86 %/75 % using a cutoff value of >11 valgus. The most accurate measurement on MR images to detect abnormal hindfoot varus was the sustentaculum tangent, reaching a sensitivity/specificity of 91 %/71 % using a cutoff value of <12 valgus. It is possible to suspect abnormal hindfoot alignment on coronal non-weight-bearing MR images. (orig.)

  20. New analysis methods to push the boundaries of diagnostic techniques in the environmental sciences

    International Nuclear Information System (INIS)

    Lungaroni, M.; Peluso, E.; Gelfusa, M.; Malizia, A.; Talebzadeh, S.; Gaudio, P.; Murari, A.; Vega, J.

    2016-01-01

    In the last years, new and more sophisticated measurements have been at the basis of the major progress in various disciplines related to the environment, such as remote sensing and thermonuclear fusion. To maximize the effectiveness of the measurements, new data analysis techniques are required. First data processing tasks, such as filtering and fitting, are of primary importance, since they can have a strong influence on the rest of the analysis. Even if Support Vector Regression is a method devised and refined at the end of the 90s, a systematic comparison with more traditional non parametric regression methods has never been reported. In this paper, a series of systematic tests is described, which indicates how SVR is a very competitive method of non-parametric regression that can usefully complement and often outperform more consolidated approaches. The performance of Support Vector Regression as a method of filtering is investigated first, comparing it with the most popular alternative techniques. Then Support Vector Regression is applied to the problem of non-parametric regression to analyse Lidar surveys for the environments measurement of particulate matter due to wildfires. The proposed approach has given very positive results and provides new perspectives to the interpretation of the data.

  1. Analysis of Current Visualization Techniques and Main Challenges for the Future

    Directory of Open Access Journals (Sweden)

    Manuel Pérez Cota

    2017-08-01

    Full Text Available The big amount of data generated nowadays are being used by Big Data tools to generate knowledge and to facilitate the decision-making. However, this situation creates a new challenge: how to visualize all these data without losing mid/long term crucial information. The purpose of this article is to analyze the state of the art on massive data visualization, main problems and challenges of information representation current techniques as well as the evolution of the tools and the future of them, in other words, new functionalities to offer.

  2. [A study of the value of three molecular diagnostic techniques in the diagnosis of tuberculosis].

    Science.gov (United States)

    Huang, Fang; Dang, Liyun; Sun, Huiping; Yang, Han; Wu, Xia

    2015-09-01

    To evaluate the diagnostic value of real-time fluorescent RNA isothermal amplification detection technology (simultaneous amplification and testing, SAT), Mycobacterium nucleic acid detection (PCR-fluorescence probe)method (TB-NTM-PCR) and Xpert MTB/RIF detection in the diagnosis of tuberculosis. A total of 378 sputum specimens from pulmonary tuberculosis patients were collected between April to July 2014 in Xi'an Thoracic Tumor and Tuberculosis Hospital. The specimens were detected by 5 methods at the same time including acid-fast stain, SAT method, TB-NTM-PCR method, TB 960 rapid liquid culture and Xpert MTB/RIF. The sensitivity and specificity of SAT method, TB-NTM-PCR method and Xpert MTB/RIF were calculated according to the results of TB 960 rapid liquid culture and staining. The difference among all the 3 methods was analyzed by Chi-squared test. The positive rate of SAT-TB,TB-NTM-PCR and Xpert MTB/RIF were 37.6% (142/378), 37.8% (143/378) and 53.4% (202/378), respectively. In specimens both positive for acid-fast stain and culture, the positive rate of SAT method was 84.6% (77/91), that of TB-NTM-PCR was 91.2% (83/91), and that of Xpert MTB/RIF was 96.7% (88/91), the difference being significant (P=0.018 2). In specimens negative for acid-fast stain but positive for culture, the positive rate of SAT method was 61.9% (60 /97), that of TB-NTM-PCR was 44.3% (43/97), and that of Xpert MTB/RIF was 80.4% (78/97), the difference being significant (Pmolecular detection methods showed good results for the auxiliary diagnosis of tuberculosis. Xpert MTB/RIF had the best performance both in smear positive and negative specimens and it can detect rifampicin related rpoB gene mutations at the same time.

  3. MR-defecography in obstructed defecation syndrome (ODS): technique, diagnostic criteria and grading.

    Science.gov (United States)

    Piloni, V; Tosi, P; Vernelli, M

    2013-10-01

    The aim of this study was to evaluate the use of a magnetic resonance (MR)-based classification system of obstructive defecation syndrome (ODS) to guide physicians in patient management. The medical records and imaging series of 105 consecutive patients (90 female, 15 male, aged 21-78 years, mean age 46.1 ± 5.1 years) referred to our center between April 2011 and January 2012 for symptoms of ODS were retrospectively examined. After history taking and a complete clinical examination, patients underwent MR imaging according to a standard protocol using a 0.35 T permanent field, horizontally oriented open-configuration magnet. Static and dynamic MR-defecography was performed using recognized parameters and well-established diagnostic criteria. Sixty-seven out of 105 (64 %) patients found the prone position more comfortable for the evacuation of rectal contrast while 10/105 (9.5 %) were unable to empty their rectum despite repeated attempts. Increased hiatus size, anterior rectocele and focal or extensive defects of the levator ani muscle were the most frequent abnormalities (67.6, 60.0 and 51.4 %, respectively). An MR-based classification was developed based on the combinations of abnormalities found: Grade 1 = functional abnormality, including paradoxical contraction of the puborectalis muscle, without anatomical defect affecting the musculo-fascial structures; Grade 2 = functional defect associated with a minor anatomical defect such as rectocele ≤ 2 cm in size and/or first-degree intussusception; Grade 3 = severe defects confined to the posterior anatomical compartment, including >2 cm rectocele, second- or higher-degree intussusception, full-thickness external rectal prolapse, poor mesorectal posterior fixation, rectal descent >5 cm, levator ani muscle rupture, ballooning of the levator hiatus and focal detachment of the endopelvic fascia; Grade 4 = combined defects of two or three pelvic floor compartments, including cystocele, hysterocele, enlarged urogenital

  4. Feedback control of persistent-current oscillation based on the atomic-clock technique

    Science.gov (United States)

    Yu, Deshui; Dumke, Rainer

    2018-05-01

    We propose a scheme of stabilizing the persistent-current Rabi oscillation based on the flux qubit-resonator-atom hybrid structure. The low-Q L C resonator weakly interacts with the flux qubit and maps the persistent-current Rabi oscillation of the flux qubit onto the intraresonator electric field. This oscillating electric field is further coupled to a Rydberg-Rydberg transition of the 87Rb atoms. The Rabi-frequency fluctuation of the flux qubit is deduced from measuring the atomic population via the fluorescence detection and stabilized by feedback controlling the external flux bias. Our numerical simulation indicates that the feedback-control method can efficiently suppress the background fluctuations in the flux qubit, especially in the low-frequency limit. This technique may be extensively applicable to different types of superconducting circuits, paving a way to long-term-coherence superconducting quantum information processing.

  5. Hysteresis current control technique of VSI for compensation of grid-connected unbalanced loads

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Akorede, Mudathir Funsho; Montesinos-Miracle, Daniel

    2014-01-01

    interconnection issues that usually arise as DG units connect to the electric grid. The proposed strategy, implemented in Matlab/Simulink environment in different operating scenarios, provides compensation for active, reactive, unbalanced, and harmonic current components of grid-connected nonlinear unbalanced...... resources as they connect to the exiting power grid could provoke many power quality problems on the grid side. For this reason, due considerations must be given to power generation and safe running before DG units is actually integrated into the power grid. The main aim of this paper is to address the grid...... loads. The simulation results obtained in this study demonstrate the level of accuracy of the proposed technique, which ensure a balance in the overall grid phase currents, injection of maximum available power from DG resources to the grid, improvement of the utility grid power factor, and a reduction...

  6. Current literature and imaging techniques of aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL)

    International Nuclear Information System (INIS)

    Duggan, P.J.; Burke, C.J.; Saha, S.; Moonim, M.; George, M.; Desai, A.; Houghton, R.

    2013-01-01

    Aseptic lymphocyte-dominated vasculitis-associated lesions (ALVAL) are a recognized complication of metal-on-metal bearing hip prostheses. There is an impending concern regarding the future investigation and management of patients who have received such implants. The current literature is discussed, and the current guidelines for management of these patients in the UK are reviewed. The various imaging techniques available, such as computed tomography, metal artefact reduction magnetic resonance imaging, and ultrasound are discussed and evaluated with respect to the assessment of patients with suspected ALVAL. The histopathological findings are discussed with images of the tissue changes provided. Images of the radiological findings are also provided for all general radiological methods. ALVAL and its radiological presentation is an important issue that unfortunately may become a significant clinical problem

  7. Sportsmen's Groin-Diagnostic Approach and Treatment With the Minimal Repair Technique: A Single-Center Uncontrolled Clinical Review.

    Science.gov (United States)

    Muschaweck, Ulrike; Berger, Luise Masami

    2010-05-01

    Sportsmen's groin, also called sports hernia and Gilmore groin, is one of the most frequent sports injuries in athletes and may place an athletic career at risk. It presents with acute or chronic groin pain exacerbated with physical activity. So far, there is little consensus regarding pathogenesis, diagnostic criteria, or treatment. There have been various attempts to explain the cause of the groin pain. The assumption is that a circumscribed weakness in the posterior wall of the inguinal canal, which leads to a localized bulge, induces a compression of the genital branch of the genitofemoral nerve, considered responsible for the symptoms. The authors developed an innovative open suture repair-the Minimal Repair technique-to fit the needs of professional athletes. With this technique, the circumscribed weakness of the posterior wall of the inguinal canal is repaired by an elastic suture; the compression on the nerve is abolished, and the cause of the pain is removed. In contrast with that of common open suture repairs, the defect of the posterior wall is not enlarged, the suture is nearly tension free, and the patient can return to full training and athletic activity within a shorter time. The outcome of patients undergoing operations with the Minimal Repair technique was compared with that of commonly used surgical procedures. THE FOLLOWING ADVANTAGES OF THE MINIMAL REPAIR TECHNIQUE WERE FOUND: no insertion of prosthetic mesh, no general anesthesia required, less traumatization, and lower risk of severe complications with equal or even faster convalescence. In 2009, a prospective cohort of 129 patients resumed training in 7 days and experienced complete pain relief in an average of 14 days. Professional athletes (67%) returned to full activity in 14 days (median). The Minimal Repair technique is an effective and safe way to treat sportsmen's groin.

  8. A hybrid body technique: does the pulse diagnostic cun guan chi method have Chinese-Tibetan origins?

    Science.gov (United States)

    Hsu, Elisabeth

    2008-01-01

    This article investigates the medieval origins of the main pulse diagnostic method in contemporary Chinese medicine, sometimes known as san bu (three sectors) method, which requires physicians to examine the mai (vessels, vessel movements or pulse) on the wrist at the three locations cun guan chi (inch, gate, foot). The article provides evidence to suggest that this body technique grew out of an earlier Chinese one, the cun chi (inch-foot) method, which appears to have aimed at investigating the qualities of yin and yang in order to determine the condition of a patient by means of exploring fairly large areas of the patient's body surface with the palms. The article furthermore posits that the cun chi method was decisively transformed in medieval times, presumably due to the impact of early Tibetan pulse diagnostic practices: it became framed in a numerology of three and started advocating the use of the fingertips for sensing the pulse beats. The article, which draws on detailed textual analyses of medieval manuscripts, on visual evidence and also on psychophysical research, furthermore highlights how misunderstandings can constructively contribute to cultural communication.

  9. Laser diagnodent: a comparative study with other diagnostic techniques; Laser diagnodent: estudo comparativo com outras tecnicas de diagnostico

    Energy Technology Data Exchange (ETDEWEB)

    Godinho, Reugma Rego

    2002-07-01

    An evaluation of the Diagnodent equipment (Kavo Company, Germany) for the occlusal caries detection was dane through the comparison with other conventional diagnostic techniques, such as visual inspection, intra-oral micro camera and digital X-ray. The effectiveness of the equipment in the detection of hidden caries and its viability as a diagnosis method for caries in their initial stage was also studied. Fifty eight permanent molars and premolars teeth from patients with age between 6 and 30 years were studied. The obtained results indicated that the conventional methods employed for the caries diagnosis are unable to detect the carious lesion in its initial stage. The Diagnodent equipment has this capability to detect caries presenting a flawless surface, specially the hidden caries, allowing the dentist to decide between a preventive ar a conservative procedure. The main advantage of the Diagnodent is to be an objective method, compared to the visual and radiographic ones, that are dependent on the professional interpretation. The Diagnodent is, therefore, a promising alternative as an objective and standardized diagnosis method for the final diagnostic. (author)

  10. Diagnostic accuracy of magnetic resonance imaging techniques for treatment response evaluation in patients with head and neck tumors, a systematic review and meta-analysis

    NARCIS (Netherlands)

    van der Hoorn, Anouk; van Laar, Peter Jan; Holtman, Gea A.; Westerlaan, Henriette E.

    2017-01-01

    Background Novel advanced MRI techniques are investigated in patients treated for head and neck tumors as conventional anatomical MRI is unreliable to differentiate tumor from treatment related imaging changes. Purpose As the diagnostic accuracy of MRI techniques to detect tumor residual or

  11. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods.

    Science.gov (United States)

    Barbosa, José Augusto A; Rodrigues, Alexandre B; Mota, Cleonice Carvalho C; Barbosa, Márcia M; Simões e Silva, Ana C

    2011-01-01

    Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.

  12. Laboratory experiment on the 3D tide-induced Lagrangian residual current using the PIV technique

    Science.gov (United States)

    Chen, Yang; Jiang, Wensheng; Chen, Xu; Wang, Tao; Bian, Changwei

    2017-12-01

    The 3D structure of the tide-induced Lagrangian residual current was studied using the particle image velocimetry (PIV) technique in a long shallow narrow tank in the laboratory. At the mouth of the tank, a wave generator was used to make periodic wave which represents the tide movement, and at the head of the tank, a laterally sloping topography with the length of one fifth of the water tank was installed, above which the tide-induced Lagrangian residual current was studied. Under the weakly nonlinear condition in the present experiment setup, the results show that the Lagrangian residual velocity (LRV) field has a three-layer structure. The residual current flows inwards (towards the head) in the bottom layer and flows outwards in the middle layer, while in the surface layer, it flows inwards along the shallow side of the sloping topography and outwards along the deep side. The depth-averaged and breadth-averaged LRV are also analyzed based on the 3D LRV observations. Our results are in good agreement with the previous experiment studies, the analytical solutions with similar conditions and the observational results in real bays. Moreover, the volume flux comparison between the Lagrangian and Eulerian residual currents shows that the Eulerian residual velocity violates the mass conservation law while the LRV truly represents the inter-tidal water transport. This work enriches the laboratory studies of the LRV and offers valuable references for the LRV studies in real bays.

  13. Diagnostic accuracy of dynamic contrast-enhanced MR imaging of renal masses with rapid-acquisition spin-echo technique

    International Nuclear Information System (INIS)

    Eilenberg, S.S.; Lee, J.K.T.; Brown, J.J.; Heiken, J.P.; Mirowitz, S.A.

    1990-01-01

    This paper compares the diagnostic accuracy of Gd-DTPA-enhanced rapid-acquisition spin-echo (RASE) imaging with standard spin-echo techniques for detecting renal cysts and solid renal neoplasms. RASE imaging combines a short TR (275 msec)/short TE (10 msec), single excitation pulse sequence with half-Fourier data sampling. Eighteen patients with CT evidence of renal masses were first evaluated with standard T1-and T2-weighted SE sequences. Pre- and serial postcontrast (Cd-DTPA, 0.1 mmol./kg) RASE sequences were then performed during suspended respiration. A final set of postcontrast images was obtained with the standard T1-weighted SE sequence. Each set of MR images was first reviewed separately (ie, T1, T2, pre- and post-contrast RASE, etc)

  14. Diagnostic value of renal clearance techniques using iodo-hippuran /sup 131/I and /sup 99m/-DTPA

    Energy Technology Data Exchange (ETDEWEB)

    Heidenreich, P; Hoer, G [Technische Univ. Muenchen (Germany, F.R.). Nuklearmedizinische Klinik und Poliklinik

    1976-01-01

    Methods and clinical indications of divided renal clearance determination using /sup 131/I-hippuran are presented and their value as a diagnostic tool in urology is shown by two case reports. For quantitative assessment of renal function we prefer the whole body clearance (with partial shielding of kidneys and bladder) which obviates the necessity of the theoretical assumption of compartmental distribution of radiopharmaceuticals. Using simplified clearance techniques only based on analysis of plasma disappearance curves (slope clearance one- and two-compartment model), clinically useful results are also obtainable, especially in follow up studies. The evaluation of tubular and glomerular kidney function by simultaneous application of /sup 131/I-hippuran and sup(99m)Tc-DTPA is suitable for estimation of filtration fraction in patients with urological and nephrological diseases. Even with regard to therapy and follow up studies of urinary tract tuberculosis, remarkable dignostic informations may be achieved.

  15. SU-F-T-427: Utilization and Evaluation of Diagnostic CT Imaging with MAR Technique for Radiation Therapy Treatment Planning

    International Nuclear Information System (INIS)

    Xu, M; Foster, R; Parks, H; Pankuch, M

    2016-01-01

    Purpose: The objective was to utilize and evaluate diagnostic CT-MAR technique for radiation therapy treatment planning. Methods: A Toshiba-diagnostic-CT acquisition with SEMAR(Single-energy-MAR)-algorism was performed to make the metal-artifact-reduction (MAR) for patient treatment planning. CT-imaging datasets with and without SEMAR were taken on a Catphan-phantom. Two sets of CT-numbers were calibrated with the relative electron densities (RED). A tissue characterization phantom with Gammex various simulating material rods was used to establish the relationship between known REDs and corresponding CT-numbers. A GE-CT-sim acquisition was taken on the Catphan for comparison. A patient with bilateral hip arthroplasty was scanned in the radiotherapy CT-sim and the diagnostic SEMAR-CT on a flat panel. The derived SEMAR images were used as a primary CT dataset to create contours for the target, critical-structures, and for planning. A deformable registration was performed with VelocityAI to track voxel changes between SEMAR and CT-sim images. The SEMAR-CT images with minimal artifacts and high quality of geometrical and spatial integrity were employed for a treatment plan. Treatment-plans were evaluated based on deformable registration of SEMAR-CT and CT-sim dataset with assigned CT-numbers in the metal artifact regions in Eclipse v11 TPS. Results: The RED and CT-number relationships were consistent for the datasets in CT-sim and CT’s with and without SEMAR. SEMAR datasets with high image quality were used for PTV and organ delineation in the treatment planning process. For dose distribution to the PTV through the DVH analysis, the plan using CT-sim with the assigned CT-number showed a good agreement to those on deformable CT-SEMAR. Conclusion: A diagnostic-CT with MAR-algorithm can be utilized for radiotherapy treatment planning with CT-number calibrated to the RED. Treatment planning comparison and DVH shows a good agreement in the PTV and critical organs between

  16. Applications of pulsed Eddy Current (PEC) technique on defect and material assessment

    International Nuclear Information System (INIS)

    Nurul A'in Ahmad Latif; Noorhazleena Azaman; Ilham Mukriz Zainal Abidin

    2014-01-01

    The pulsed eddy current (PEC) is an emerging electromagnetic method and widely used in multiple field including aerospace, petrochemical, industry and transportation. PEC mainly depends on the multiple variables such as peak value and rising time to detect and quantify the defects. Apart of its advantage as non contacting technique, it has ability on conducting surface and subsurface detection. Additionally, PEC is high sensitive to variety parameters that are inherent in the flaws. Compare to conventional eddy current, PEC allows deeper penetration as it is a combination from multiple frequencies. This paper demonstrates the abilities of PEC technique performing multiple testing in various fields such as conducting conductivity testing, measuring the material thickness and identifying depth of the defects. The conductivity testing will be performed on multiple materials such as aluminium, stainless steel, copper, austenitic steel and titanium. To measure the material thicknesses, PEC testing will be conducted on the multi layered specimen with the different thickness. Meanwhile to identify depth of defects, the testing will be carried out using a stainless steel calibration block contains multiple length of defect. For the validation purposes, all the results generate through the experiments will be compared with simulation results produced using dedicated software, COMSOL. (author)

  17. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature.

    Science.gov (United States)

    Singh, Iqbal

    2009-10-01

    To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN). We searched the published English literature and the PubMed(()) for published series of 'robotic partial nephrectomy' (RPN) using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. The search yielded 15 major selected series of 'robotic partial nephrectomy'; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s), as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T(1)) renal neoplasm(s). It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN) are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  18. Technique for the comparison of light spectra from natural and laboratory generated lightning current arcs

    International Nuclear Information System (INIS)

    Mitchard, D.; Clark, D.; Carr, D.; Haddad, A.

    2016-01-01

    A technique was developed for the comparison of observed emission spectra from lightning current arcs generated through self-breakdown in air and the use of two types of initiation wire, aluminum bronze and nichrome, against previously published spectra of natural lightning events. A spectrograph system was used in which the wavelength of light emitted by the lightning arc was analyzed to derive elemental interactions. A lightning impulse of up to 100 kA was applied to a two hemispherical tungsten electrode configuration which allowed the effect of the lightning current and lightning arc length to be investigated. A natural lightning reference spectrum was reconstructed from literature, and generated lightning spectra were obtained from self-breakdown across a 14.0 mm air gap and triggered along initiation wires of length up to 72.4 mm. A comparison of the spectra showed that the generated lightning arc induced via self-breakdown produced a very similar spectrum to that of natural lightning, with the addition of only a few lines from the tungsten electrodes. A comparison of the results from the aluminum bronze initiation wire showed several more lines, whereas results from the nichrome initiation wire differed greatly across large parts of the spectrum. This work highlights the potential use for spectrographic techniques in the study of lightning interactions with surrounding media and materials, and in natural phenomena such as recently observed ball lightning.

  19. 2-D image diagnostic technique for edge turbulence using fast cameras

    International Nuclear Information System (INIS)

    Nishino, N.; Mizuuchi, T.; Feng, Z.

    2007-01-01

    Fast cameras are powerful tool to visualize the edge turbulence in peripheral plasmas. Under Bi-directional collaborations recently in Heliotron J and GAMMA10 filamentary structures along the magnetic field line were firstly observed with GPI (gas puff imaging) by fast camera. In both machines the filamentary structures had similar stripe pattern in the images and simultaneous measurements of the ion saturation current by electrostatic probes show that the filamentary structures were relatively higher electron density/temperature regions in peripheral plasmas. It is not sufficient to conclude both filamentary structures are the same, however, these phenomena were thought to be related to the energy confinement. Thus the physics mechanism should be solved in the near future. (author)

  20. Forensic palynology: current status of a rarely used technique in the United States of America.

    Science.gov (United States)

    Bryant, Vaughn M; Jones, Gretchen D

    2006-11-22

    The United States of America would seem to be an excellent location for using pollen data in forensic applications. The vegetation within the region is highly diverse ranging from areas of Arctic tundra to some of the most inhospitable deserts anywhere in the Western Hemisphere. The highly varied ecology, great plant diversity, thousands of vegetational microhabitats, and extensive published pollen records for the region provide an ideal setting for these types of analyses. This diversity, often characterized in most locations by unique combinations of pollen types, makes the use of forensic pollen a reliable technique that can often be used to associate individuals with a unique crime scene or geographical region. Nevertheless, forensic pollen studies in the United States of America are currently one of the most highly under utilized techniques available to assist in solving criminal and civil cases. During the past century there has been a very limited attempt to use pollen evidence in either criminal or civil cases, for a variety of reasons, including a lack of available information about the technique, a very limited number of specialists trained to do forensic pollen work, and an almost total absence of academic centers able to train needed specialists or forensic facilities able, or willing, to fund research in this area. Hopefully, this paucity of use will change if certain steps are taken to encourage the routine collection and use of pollen evidence in both criminal and civil cases.

  1. Cardiovascular dysfunction in obesity and new diagnostic imaging techniques: the role of noninvasive image methods

    Directory of Open Access Journals (Sweden)

    Barbosa JA

    2011-05-01

    Full Text Available José Augusto A Barbosa¹, Alexandre B Rodrigues¹, Cleonice Carvalho C Mota¹, Márcia M Barbosa², Ana C Simões e Silva¹¹Department of Pediatrics, Faculty of Medicine, Federal University of Minas Gerais (UFMG, Belo Horizonte, Minas Gerais, Brazil; ²Ecocenter, Socor Hospital, Belo Horizonte, Minas Gerais, BrazilAbstract: Obesity is a major public health problem affecting adults and children in both developed and developing countries. This condition often leads to metabolic syndrome, which increases the risk of cardiovascular disease. A large number of studies have been carried out to understand the pathogenesis of cardiovascular dysfunction in obese patients. Endothelial dysfunction plays a key role in the progression of atherosclerosis and the development of coronary artery disease, hypertension and congestive heart failure. Noninvasive methods in the field of cardiovascular imaging, such as measuring intima-media thickness, flow-mediated dilatation, tissue Doppler, and strain, and strain rate, constitute new tools for the early detection of cardiac and vascular dysfunction. These techniques will certainly enable a better evaluation of initial cardiovascular injury and allow the correct, timely management of obese patients. The present review summarizes the main aspects of cardiovascular dysfunction in obesity and discusses the application of recent noninvasive imaging methods for the early detection of cardiovascular alterations.Keywords: cardiovascular risk, endothelium dysfunction, obesity, strain and strain rate, tissue Doppler

  2. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Calder, Alistair D. [Great Ormond Street Hospital for Children NHS Foundation Trust, Radiology Department, London (United Kingdom); Offiah, Amaka C. [Sheffield Children' s NHS Foundation Trust, Academic Unit of Child Health, Sheffield (United Kingdom)

    2015-04-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  3. Foetal radiography for suspected skeletal dysplasia: technique, normal appearances, diagnostic approach

    International Nuclear Information System (INIS)

    Calder, Alistair D.; Offiah, Amaka C.

    2015-01-01

    Despite advances in antenatal imaging and genetic techniques, post-delivery post-mortem foetal radiography remains the key investigation in accurate diagnosis of skeletal dysplasia manifesting in the foetus. Foetal radiography is best performed using pathology-specimen radiography equipment and is often carried out in the pathology department without involvement of the radiology unit. However, paediatric radiologists may be asked to interpret post-mortem foetal radiographs when an abnormality is suspected. Many foetal radiographs are carried out before 20 weeks' gestation, and the interpreting radiologist needs to be familiar with the range of normal post-mortem foetal appearances at different gestational ages, as well as the appearances of some of the more commonly presenting skeletal dysplasias, and will benefit from a systematic approach when assessing more challenging cases. In this pictorial essay, we illustrate various normal post-mortem foetal radiographic appearances, give examples of commonly occurring skeletal dysplasias, and describe an approach to establishing more difficult diagnoses. (orig.)

  4. Development of a visible framing camera diagnostic for the study of current initiation in z-pinch plasmas

    International Nuclear Information System (INIS)

    Muron, D.J.; Hurst, M.J.; Derzon, M.S.

    1996-01-01

    The authors assembled and tested a visible framing camera system to take 5 ns FWHM images of the early time emission from a z-pinch plasma. This diagnostic was used in conjunction with a visible streak camera allowing early time emissions measurements to diagnose current initiation. Individual frames from gated image intensifiers were proximity coupled to charge injection device (CID) cameras and read out at video rate and 8-bit resolution. A mirror was used to view the pinch from a 90-degree angle. The authors observed the destruction of the mirror surface, due to the high surface heating, and the subsequent reduction in signal reflected from the mirror. Images were obtained that showed early time ejecta and a nonuniform emission from the target. This initial test of the equipment highlighted problems with this measurement. They observed non-uniformities in early time emission. This is believed to be due to either spatially varying current density or heating of the foam. Images were obtained that showed early time ejecta from the target. The results and suggestions for improvement are discussed in the text

  5. Diagnostic radiography students' perceptions of formative peer assessment within a radiographic technique module

    International Nuclear Information System (INIS)

    Elshami, W.; Abdalla, M.E.

    2017-01-01

    Introduction: Assessment is a central part of student learning. Student involvement in peer assessment leads to significant improvement in students' performance, supports students' learning, promotes the development of evaluation skills and encourages reflection. Aim: The aim of this study is to assess perceptions of the Formative Peer Assessment (FPA) initiative within a higher education setting for undergraduate radiography students. Methods: Qualitative action research was conducted. Students were allowed to anonymously assess each other's assignments using a standardized evaluation sheet that they had been trained to use. Participants' perceptions were assessed through focus group discussion. Results: The findings showed that students' experiences with peer assessment were positive. Students acknowledged that they received valuable feedback and learned from assessing their peers. Students recommended the need for training and suggested using more than one evaluator. Conclusion: The FPA initiative in the study institution believed to be succeed as the students had a positive experience with the FPA. Students learnt from PA and from self-assessment. Implementation of PA will promote reflection and critical thinking and problem solving skills, that are important traits in radiography graduate profile as in radiography clinical practice the professional require to modify imaging techniques and critique images to ensure the quality of care. - Highlights: • Participants had a positive experience with the Formative Peer Assessment (FPA). • Students believed that the FPA had a positive impact on their learning. • FPA was time-consuming but benefits outweigh the extra time commitment. • Comprehensive training and detailed grading rubric are recommended to improve FPA.

  6. Novel Method for Sizing Metallic Bottom Crack Depth Using Multi-frequency Alternating Current Potential Drop Technique

    OpenAIRE

    Li Yuting; Gan Fangji; Wan Zhengjun; Liao Junbi; Li Wenqiang

    2015-01-01

    Potential drop techniques are of two types: the direct current potential drop (DCPD) technique and alternating current potential drop (ACPD) technique, and both of them are used in nondestructive testing. ACPD, as a kind of valid method in sizing metal cracks, has been applied to evaluate metal structures. However, our review of most available approaches revealed that some improvements can be done in measuring depth of metal bottom crack by means of ACPD, such as accuracy and sensitivity of s...

  7. Mass spectrometer diagnostic technique in the study of stationary afterglow plasmas in helium, argon and krypton

    International Nuclear Information System (INIS)

    Langenwalter, M.

    1979-01-01

    Since some years the method of massspectrometric monitoring has become an important tool in the analysis of time resolved (or stationary) afterglow plasmas. The present thesis reports the construction and testing of a new fully bakeable UHV-stationary-afterglow-apparatus using a hollow cathode discharge as plasma source for the first time. The hollow cathode is moveable perpendicular to its axis relative to the sampling orifice (i.e. a very small hole at the centre of the plasma container's boundary), so that the radical distribution of the charged particle density can be studied. Several specific extraction conditions for ions from the plasma especially the sampling probe potential have been systematically investigated. Results are illustrated and discussed. The new apparatus has been tested by determining the ambipolar diffusion coefficient of the molecular ion He 2 + in a pure Helium-plasma in thermal equilibrium. The present result (Dsub(a2) = 603 +- 38 / P 0 cm 2 s -1 ) is in agreement with results reported by other workers. Finally an example for the radial behaviour of the Ar + -sampling current in an Argon-discharge for several different times in the afterglow period is given. The shown behaviour agrees relatively well with the theoretically predicted radial ion density distribution, i.e. the zero-order Ressel'function. (Author)

  8. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    International Nuclear Information System (INIS)

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda

    2013-01-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m 3 of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m 3 of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both a local

  9. Currents trends in the application of IBA techniques to air pollution source fingerprinting and source apportionment

    Energy Technology Data Exchange (ETDEWEB)

    Cohen, David; Stelcer, Ed.; Atanacio, Armand; Crawford, Jagoda [Australian Nuclear Science and Technology Organisation, Kirrawee DC (Australia)

    2013-07-01

    Full text: IBA techniques have been used for many years to characterise fine particle air pollution. This is not new the techniques are well established. Typically 2-3 MeV protons are used to bombard thin filter papers and up to four simultaneous techniques like PIXE, PIGE, RBS and ERDA will be applied to obtain (μg/g) concentrations for elements from hydrogen to lead. Generally low volume samplers are used to sample between 20-30 m{sup 3} of air over a 24 hour period, this together with IBA's sensitivity means that concentrations down to 1 ng/m{sup 3} of air sampled can be readily achieved with only a few minutes of proton irradiation. With these short irradiation times and low sensitivities for a broad range of elements in the periodic table, large numbers of samples can be obtained and analysed very quickly and easily. At ANSTO we have used IBA methods to acquire a database of over 50,000 filters from 85 different sites through Australia and Asia, each filter has been analysed for more than 21 different chemical species. Large databases extending over many years means that modern statistical techniques like positive matrix factorisation (PMF) can be used to define well characterised source fingerprints and source contributions for a range of different fine particle air pollutants. In this paper we will discuss these PMF techniques and show how they identify both natural sources like sea spray and windblown soils as well as anthropogenic sources like automobiles, biomass burning, coal-fired power stations and industrial emissions. These data are particularly useful for Governments, EPA's and managers of pollution to better understanding pollution sources and their relative contributions and hence to better manage air pollution. Current trends are to take these IBA and PMF techniques a step further and to combine them with wind speed and back trajectory data to better pin point and identify emission sources. We show how this is now being applied on both

  10. The diagnostic value of double-contrast-technique cystography in the evaluation of benign and malignant lesions of the urinary bladder

    International Nuclear Information System (INIS)

    Beyer, D.; Koester, R.; Schuett, H.

    1979-01-01

    Cystography by double-contrast-technique as simple and quick method of evaluating benign and malignant lesions of the urinary bladder is being described. 301 examinations were reviewed and are being discussed in regard to diagnostic value, indication, complication and radiation exposure of this method. A few typical cases are being demonstrated to illustrate the value of this method in the spectrum of other diagnostic methods in the workup of urinary bladder lesions. (orig.) [de

  11. Influence of crack length on crack depth measurement by an alternating current potential drop technique

    International Nuclear Information System (INIS)

    Raja, Manoj K; Mahadevan, S; Rao, B P C; Behera, S P; Jayakumar, T; Raj, Baldev

    2010-01-01

    An alternating current potential drop (ACPD) technique is used for sizing depth of surface cracks in metallic components. Crack depth estimations are prone to large deviations when ACPD measurements are made on very shallow and finite length cracks, especially in low conducting materials such as austenitic stainless steel (SS). Detailed studies have been carried out to investigate the influence of crack length and aspect ratio (length to depth) on depth estimation by performing measurements on electric discharge machined notches with the aspect ratio in the range of 1 to 40 in SS plates. In notches with finite length, an additional path for current to flow through the surface along the length is available causing the notch depths to be underestimated. The experimentally observed deviation in notch depth estimates is explained from a simple mathematical approach using the equivalent resistive circuit model based on the additional path available for the current to flow. A scheme is proposed to accurately measure the depth of cracks with finite lengths in SS components

  12. Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind-Hydro Hybrid System

    Science.gov (United States)

    Ram Prabhakar, J.; Ragavan, K.

    2013-07-01

    This article proposes new power management based current control strategy for integrated wind-solar-hydro system equipped with battery storage mechanism. In this control technique, an indirect estimation of load current is done, through energy balance model, DC-link voltage control and droop control. This system features simpler energy management strategy and necessitates few power electronic converters, thereby minimizing the cost of the system. The generation-demand (G-D) management diagram is formulated based on the stochastic weather conditions and demand, which would likely moderate the gap between both. The features of management strategy deploying energy balance model include (1) regulating DC-link voltage within specified tolerances, (2) isolated operation without relying on external electric power transmission network, (3) indirect current control of hydro turbine driven induction generator and (4) seamless transition between grid-connected and off-grid operation modes. Furthermore, structuring of the hybrid system with appropriate selection of control variables enables power sharing among each energy conversion systems and battery storage mechanism. By addressing these intricacies, it is viable to regulate the frequency and voltage of the remote network at load end. The performance of the proposed composite scheme is demonstrated through time-domain simulation in MATLAB/Simulink environment.

  13. CANDU fuel sheath integrity and oxide layer thickness determination by Eddy current technique

    International Nuclear Information System (INIS)

    Gheorghe, Gabriela; Man, Ion; Parvan, Marcel; Valeca, Serban

    2010-01-01

    This paper presents results concerning the integrity assessment of the fuel elements cladding and measurements of the oxide layer on sheaths, using the eddy current technique. Flaw detection using eddy current provides information about the integrity of fuel element sheath or presence of defects in the sheath produced by irradiation. The control equipment consists of a flaw detector with eddy currents, operable in the frequency range 10 Hz to 10 MHz, and a differential probe. The calibration of the flaw detector is done using artificial defects (longitudinal, transversal, external and internal notches, bored and unbored holes) obtained on Zircaloy-4 tubes identical to those out of which the sheath of the CANDU fuel element is manufactured (having a diameter of 13.08 mm and a wall thickness of 0.4 mm). When analyzing the behavior of the fuel elements' cladding facing the corrosion is important to know the thickness of the zirconium oxide layer. The calibration of the device measuring the thickness of the oxide layer is done using a Zircaloy-4 tube identical to that which the cladding of the CANDU fuel element is manufactured of, and calibration foils, as well. (authors)

  14. Radioisotopic and thermographic imaging of the lower limbs oedema - comparison diagnostic techniques

    International Nuclear Information System (INIS)

    Stepien, A.; Pawlus, J.; Nowak, E.; Kulka, J.; Gielzycki, J.; Kraft, O.

    2005-01-01

    In this paper, authors achieved comparison between lymphoscintigraphy and thermography in patients with limbs oedema. It allow to determinate current role of lymphoscintigraphy and verify useful of thermography in limbs oedema diagnosis. Analysis included 60 patients with the lower limbs oedema. Each patients Doppler duplex scan and thermographic study was performed. Additionally, 10 patients were classified to the lymphoscintigraphy. Thermography: In studies camera ThermaCAM S60 (FLIR SYSTEM) were used. Infrared radiation detector was 320 x 240 uncooled microbolometers with thermal resolution - 0.08 o C (for 30 o C). Lymphoscintigraphy: Each patient received subcutaneous, in the second web space, Nanosis (schering) labeled 99m Tc. Dynamic data acquisition has been started immediately after injection the radiotracer to the both extremities using digital gamma camera X Ring (Mediso). Static study of whole body was performed after 1.5 hour. Thermal disorders were observed in 58 patients. On the base ultrasound and clinical examinations 10 patients were classified to lymphoscintigraphy. In this group in 5 cases traits lymphatic insufficient were observed. Thermographic study in group of patients with scintigraphic disorders was showed regional hypothermia, with small regions of hypothermia in tissues included oedema. Lymphoscintigraphy is a useful and indispensable tool in oedema diagnosis. In patients with insufficient of lymphatic system, thermography comparison to lymphoscintigraphy, in clinical diagnosis did not influence on the future diagnosis and therapeutics proceedings. Regional hyperthermic disorders in patients with limbs oedema, who had negative results of examinations (Doppler duplex scan and lymphoscintigraphy), could indicate on inflammatory complications. In cases of venous insufficient thermography allow to visualize specific venous disorders. (author)

  15. From a genetic innovation to mass health programmes: the diffusion of Down's Syndrome prenatal screening and diagnostic techniques in France.

    Science.gov (United States)

    Vassy, Carine

    2006-10-01

    Down's Syndrome prenatal diagnostic and screening techniques have spread widely in France over the last 30 years and are now part of the routine clinical practice of prenatal care. These techniques, which originated in the field of genetics, ultrasonography and biochemistry, were the first to provide the possibility of choosing the features of the foetus, or at least to reject some of its characteristics. They lead to new norms of healthy foetuses and a progressive acceptance of medical abortions. The aim of this paper is to understand how the use of these tests has been generalised in France despite scientific controversies about their risks and ethical questioning about a potential renewal of eugenics. It analyses the representations of public needs that have been articulated by key players in the scientific and medical fields. This research explores political and administrative decision making processes to understand how progressively widening public access to prenatal testing has been organised and funded. The results highlight the scientific and political role of biomedical researchers, the forms of involvement of health authorities and politicians, and the passive participation of the vast majority of the users. The paper also examines the characteristics of the French health system that facilitated the generalised use of the technology.

  16. The problem of sexual imbalance and techniques of the self in the Diagnostic and Statistical Manual of Mental Disorders.

    Science.gov (United States)

    Flore, Jacinthe

    2016-09-01

    This article examines the problematization of sexual appetite and its imbalances in the development of the Diagnostic and Statistical Manual of Mental Disorders (DSM) in the twentieth and twenty-first centuries. The dominant strands of historiographies of sexuality have focused on historicizing sexual object choice and understanding the emergence of sexual identities. This article emphasizes the need to contextualize these histories within a broader frame of historical interest in the problematization of sexual appetite. The first part highlights how sexual object choice, as a paradigm of sexual dysfunctions, progressively receded from medical interest in the twentieth century as the clinical gaze turned to the problem of sexual appetite and its imbalances. The second part uses the example of the newly introduced Female Sexual Interest/Arousal Disorder in the DSM-5 to explore how the Manual functions as a technique for taking care of the self. I argue that the design of the Manual and associated inventories and questionnaires paved the way for their interpretation and application as techniques for self-examination. © The Author(s) 2016.

  17. Evaluation of the Acridine Orange Fluorescence Technique and the Indirect Fluorescent Antibody as Diagnostic Tests for Tropical Theileriosis

    Directory of Open Access Journals (Sweden)

    Mahmoud

    2011-06-01

    Full Text Available This study was carried out to evaluate the use of acridine orange fluorescence technique on blood slides as a rapid diagnostic test for tropical theileriosis in comparison with the Giemsa-stained thin blood film technique. Also the indirect fluorescent antibody test has been employed for the serodiagnosis of tropical theileriosis. The study was carried out on 62 young and 48 adult Friesian cattle suffering from clinical tropical theileriosis in Qassim Region, Central Saudi Arabia, during the period from August 2006 to July 2008. For control, blood samples were also obtained from 25 young and 25 adult, clinically healthy, Friesian cattle, selected at random from different dairy farms in Qassim Region. Thin blood films were fixed with methanol and stained with Giemsa and acridine orange and were examined by two independent microbiologists. There was 100% correlation in the interpretation of slides stained with Giemsa and acridine orange both with respect to positivity and negativity, between the two microbiologists. It is concluded that if facilities are available acridine orange is a valuable alternative for screening tropical theileriosis. The method may also have potential value in the diagnosis of Theileria parva, which causes East Coast fever, and also other Theileria species. Results of the present study also showed that IFA test was not found sufficiently sensitive and specific as has been reported earlier. [Vet. World 2011; 4(8.000: 341-344

  18. Quantitative Evaluation of Defect in Stainless Steel 304 Tube Using Pulsed Eddy Current Technique

    International Nuclear Information System (INIS)

    Nurul Ain Ahmad Latif; Ilham Mukriz Zainal Abidin; Nurul Ain Ahmad Latif; Nordin Jamaludin; Zaredah Hashim; Norhayati Ramli

    2016-01-01

    Pulsed eddy current (PEC) is an advanced non-destructive testing (NDT) technique that operates based on electromagnetic principle. The excitation consists of broad frequency spectrum leading to be a potential in detecting defects that are deeply buried inside the specimen. In this paper, the experiment and simulation were conducted on stainless steel plate 304 fabricated with open surface defects having a different defect depth as an investigation towards the correlation between extracted signal feature and defect depth. Two common features; time to peak and peak value that corresponds to the location depth of defect and size of defect were used for signals analysis and evaluation. The results that acquired through finite element method (FEM) simulation were compared with experimental results for the signals evaluation and defect quantification. (author)

  19. Particular treatments in Eddy current technique. Application to the control of corrugated tubes

    International Nuclear Information System (INIS)

    1982-11-01

    When the testing of a given product shows that, owing to a particular shape of this product or to its environment, disturbing effects can hide the presence of harmful defects, use must be made of testing artifices or particular treatments enabling an efficient examination to be made. On this score, many eddy current problems are solved by means of the following processes: - use of specific sensors adapted to the geometry of the product, - spectral analysis of the analog results of analyses, - combination of the results of analyses obtained simultaneously at different frequencies (multifrequency techniques). An example of an application is given for corrugated tubes achieved by hollow and helical milling of smooth tubes [fr

  20. Current trends in pedicle screw stimulation techniques: lumbosacral, thoracic, and cervical levels.

    Science.gov (United States)

    Isley, Michael R; Zhang, Xiao-Feng; Balzer, Jeffrey R; Leppanen, Ronald E

    2012-06-01

    Unequivocally, pedicle screw instrumentation has evolved as a primary construct for the treatment of both common and complex spinal disorders. However an inevitable and potentially major complication associated with this type of surgery is misplacement of a pedicle screw(s) which may result in neural and vascular complications, as well as impair the biomechanical stability of the spinal instrumentation resulting in loss of fixation. In light of these potential surgical complications, critical reviews of outcome data for treatment of chronic, low-back pain using pedicle screw instrumentation concluded that "pedicle screw fixation improves radiographically demonstrated fusion rates;" however the expense and complication rates for such constructs are considerable in light of the clinical benefit (Resnick et al. 2005a). Currently, neuromonitoring using free-run and evoked (triggered) electromyography (EMG) is widely used and advocated for safer and more accurate placement of pedicle screws during open instrumentation procedures, and more recently, guiding percutaneous placement (minimally invasive) where the pedicle cannot be easily inspected visually. The latter technique, evoked or triggered EMG when applied to pedicle screw instrumentation surgeries, has been referred to as the pedicle screw stimulation technique. As concluded in the Position Statement by the American Society of Neurophysiological Monitoring (ASNM), multimodality neuromonitoring using free-run EMG and the pedicle screw stimulation technique was considered a practice option and not yet a standard of care (Leppanen 2005). Subsequently, the American Association of Neurological Surgeons/Congress of Neurological Surgeons (AANS/CNS) Joint Section on Disorders of the Spine and Peripheral Nerves published their "Guidelines for the Performance of Fusion Procedures for Degenerative Disease of the Lumbar Spine" (Heary 2005, Resnick et al. 2005a, Resnick et al. 2005b). It was concluded that the "primary

  1. Development techniques and electron optical studies of high voltage, high current electron guns

    International Nuclear Information System (INIS)

    Rangarajan, L.M.; Mahadevan, S.; Ramamurthi, S.S.

    1992-01-01

    The progress of the electron gun design, limiting to axially symmetric geometries is discussed here with a view to utilise such guns for electron accelerators. The mechanical design features leading to the physical configuration of the gun with stringent tolerances are outlined. Vacuum processing is done at pressures of 1.3x10 -5 Pa. The gun employs W-filament emitter or a cathode pellet with bombarder service. A water cooled compact faraday cup is used to measure the electron current. Electron gun geometries have been studied using the computer programme. The preveance of the gun is 0.7x10 -7 A/Vsup(1.5) at 80 kV. Developmental techniques of such pulsed electron guns are described. (author). 7 refs., 5 figs

  2. Current recommendations for the study of carotid stenosis by doppler ultrasound and other imaging techniques

    International Nuclear Information System (INIS)

    Perez Matamoros, Angelica

    2012-01-01

    Ischemic cerebrovascular disease has been one of the most frequent causes of death from chronic disease, as well as cause of long-term disabilities, in both the United States, and in Latin American countries during recent years. It is therefore, important to know about it. An updated review of international recommendations to the Costa Rican health system is performed for carotid imaging study in patients at risk of accidents and ischemic cerebrovascular disease; with special emphasis on carotid Doppler ultrasonography, due to its wide availability in the medical field Costa Rican. Furthermore, certain relevant concepts of other imaging techniques currently available are listed to determine the appropriate choice of each method according to the individual patient's condition, such as conventional angiography and tomographic angiography [es

  3. Input current interharmonics in adjustable speed drives caused by fixed-frequency modulation techniques

    DEFF Research Database (Denmark)

    Soltani, Hamid; Davari, Pooya; Loh, Poh Chiang

    2016-01-01

    Adjustable Speed Drives (ASDs) based on double-stage conversion systems may inject interharmonics distortion into the grid, other than the well-known characteristic harmonic components. The problems created by interharmonics make it necessary to find their precise sources, and, to adopt an approp......Adjustable Speed Drives (ASDs) based on double-stage conversion systems may inject interharmonics distortion into the grid, other than the well-known characteristic harmonic components. The problems created by interharmonics make it necessary to find their precise sources, and, to adopt...... an appropriate strategy for minimizing their effects. This paper investigates the ASD's input current interharmonic sources caused by applying symmetrical regularly sampled fixed-frequency modulation techniques on the inverter. The interharmonics generation process is precisely formulated and comparative results...

  4. Robot-assisted laparoscopic partial nephrectomy: Current review of the technique and literature

    Directory of Open Access Journals (Sweden)

    Singh Iqbal

    2009-01-01

    Full Text Available Aim: To visit the operative technique and to review the current published English literature on the technique, and outcomes following robot-assisted laparoscopic partial nephrectomy (RPN. Materials and Methods: We searched the published English literature and the PubMed (TM for published series of ′robotic partial nephrectomy′ (RPN using the keywords; robot, robot-assisted laparoscopic partial nephrectomy, laparoscopic partial nephrectomy, partial nephrectomy and laparoscopic surgery. Results: The search yielded 15 major selected series of ′robotic partial nephrectomy′; these were reviewed, tracked and analysed in order to determine the current status and role of RPN in the management of early renal neoplasm(s, as a minimally invasive surgical alternative to open partial nephrectomy. A review of the initial peri-operative outcome of the 350 cases of select series of RPN reported in published English literature revealed a mean operating time, warm ischemia time, estimated blood loss and hospital stay, of 191 minutes, 25 minutes, 162 ml and 2.95 days, respectively. The overall computed mean complication rate of RPN in the present select series was about 7.4%. Conclusions: RPN is a safe, feasible and effective minimally invasive surgical alternative to laparoscopic partial nephrectomy for early stage (T 1 renal neoplasm(s. It has acceptable initial renal functional outcomes without the increased risk of major complications in experienced hands. Prospective randomised, controlled, comparative clinical trials with laparoscopic partial nephrectomy (LPN are the need of the day. While the initial oncological outcomes of RPN appear to be favourable, long-term data is awaited.

  5. Imaging techniques in the management of chronic kidney disease: current developments and future perspectives.

    Science.gov (United States)

    Herget-Rosenthal, Stefan

    2011-05-01

    The measurement of both renal function and structure is critical in clinical nephrology to detect, stage, and monitor chronic kidney disease (CKD). Current imaging modalities especially ultrasound (US), computed tomography, and magnetic resonance imaging (MRI) provide adequate information on structural changes but little on functional impairment in CKD. Although not yet considered first-line procedures for evaluating patients with renal disease, new US and MR imaging techniques may permit the assessment of renal function in the near future. Combined with established imaging techniques, contrast-enhanced US, dynamic contrast-enhanced MRI, blood oxygen level dependency MRI, or diffusion-weighted imaging may provide rapid, accurate, simultaneous, and noninvasive imaging of the structure of kidneys, macrovascular and microvascular renal perfusion, oxygenation, and glomerular filtration rate. Recent developments in molecular imaging indicate that pathophysiological pathways of renal diseases such as apoptosis, coagulation, fibrosis, and ischemia will be visualized at the tissue level. These major advances in imaging and developments in hardware and software could enable comprehensive imaging of renal structure and function in four dimensions (three dimensions plus time), and imaging is expected to play an increasing role in the management of CKD. Copyright © 2011 Elsevier Inc. All rights reserved.

  6. New tools, technology and techniques applied in geological sciences: current situation and future perspectives

    International Nuclear Information System (INIS)

    Ulloa, Andres

    2014-01-01

    Technological tools and work methodologies most used in the area of geological sciences are reviewed and described. The various electronic devices such as laptops, palmtops or PDA (personal digital assistant), tablets and smartphones have allowed to take field geological data and store them efficiently. Tablets and smartphones have been convenient for data collection of scientific data by the diversity of sensors that present, portability, autonomy and the possibility to install specific applications. High precision GPS in conjunction with LIDAR technology and sonar technology have been more accessible and used for geological research, generating high resolution three-dimensional models to complement geological studies. Remote sensing techniques such as high penetration radar are used to perform models of the ice thickness and topography in Antarctic. Modern three-dimensional scanning and printing techniques are used in geological science research and teaching. Currently, the advance in the computer technology has allowed to handle three-dimensional models on personal computers efficiently way and with different display options. Some, of the new areas of geology, emerged recently, are mentioned to generate a broad panorama toward where can direct geological researches in the next years [es

  7. A Smoothing Technique for the Multifractal Analysis of a Medium Voltage Feeders Electric Current

    Science.gov (United States)

    de Santis, Enrico; Sadeghian, Alireza; Rizzi, Antonello

    2017-12-01

    The current paper presents a data-driven detrending technique allowing to smooth complex sinusoidal trends from a real-world electric load time series before applying the Detrended Multifractal Fluctuation Analysis (MFDFA). The algorithm we call Smoothed Sort and Cut Fourier Detrending (SSC-FD) is based on a suitable smoothing of high power periodicities operating directly in the Fourier spectrum through a polynomial fitting technique of the DFT. The main aim consists of disambiguating the characteristic slow varying periodicities, that can impair the MFDFA analysis, from the residual signal in order to study its correlation properties. The algorithm performances are evaluated on a simple benchmark test consisting of a persistent series where the Hurst exponent is known, with superimposed ten sinusoidal harmonics. Moreover, the behavior of the algorithm parameters is assessed computing the MFDFA on the well-known sunspot data, whose correlation characteristics are reported in literature. In both cases, the SSC-FD method eliminates the apparent crossover induced by the synthetic and natural periodicities. Results are compared with some existing detrending methods within the MFDFA paradigm. Finally, a study of the multifractal characteristics of the electric load time series detrendended by the SSC-FD algorithm is provided, showing a strong persistent behavior and an appreciable amplitude of the multifractal spectrum that allows to conclude that the series at hand has multifractal characteristics.

  8. Laparoscopic Pediatric Inguinal Hernia Repair: Overview of "True Herniotomy" Technique and Review of Current Evidence.

    Science.gov (United States)

    Feehan, Brendan P; Fromm, David S

    2017-05-01

    Inguinal hernia repair is one of the most commonly performed operations in the pediatric population. While the majority of pediatric surgeons routinely use laparoscopy in their practices, a relatively small number prefer a laparoscopic inguinal hernia repair over the traditional open repair. This article provides an overview of the three port laparoscopic technique for inguinal hernia repair, as well as a review of the current evidence with respect to visualization and identification of hernias, recurrence rates, operative times, complication rates, postoperative pain, and cosmesis. The laparoscopic repair presents a viable alternative to open repair and offers a number of benefits over the traditional approach. These include superior visualization of the relevant anatomy, ability to assess and repair a contralateral hernia, lower rates of metachronous hernia, shorter operative times in bilateral hernia, and the potential for lower complication rates and improved cosmesis. This is accomplished without increasing recurrence rates or postoperative pain. Further research comparing the different approaches, including standardization of techniques and large randomized controlled trials, will be needed to definitively determine which is superior. Copyright© South Dakota State Medical Association.

  9. Additive Manufacturing Techniques in Prosthodontics: Where Do We Currently Stand? A Critical Review.

    Science.gov (United States)

    Alharbi, Nawal; Wismeijer, Daniel; Osman, Reham B

    The aim of this article was to critically review the current application of additive manufacturing (AM)/3D-printing techniques in prosthodontics and to highlight the influence of various technical factors involved in different AM technologies. A standard approach of searching MEDLINE, EMBASE, and Google Scholar databases was followed. The following search terms were used: (Prosth* OR Restoration) AND (Prototype OR Additive Manufacture* OR Compute* OR 3D-print* OR CAD/CAM) AND (Dentistry OR Dental). Hand searching the reference lists of the included articles and personal connections revealed additional relevant articles. Selection criteria were any article written in English and reporting on the application of AM in prosthodontics from 1990 to February 2016. From a total of 4,290 articles identified, 33 were seen as relevant. Of these, 3 were narrative reviews, 18 were in vitro studies, and 12 were clinical in vivo studies. Different AM technologies are applied in prosthodontics, directly and indirectly for the fabrication of fixed metal copings, metal frameworks for removable partial dentures, and plastic mock-ups and resin patterns for further conventional metal castings. Technical factors involved in different AM techniques influence the overall quality, the mechanical properties of the printed parts, and the total cost and manufacturing time. AM is promising and offers new possibilities in the field of prosthodontics, though its application is still limited. An understanding of these limitations and of developments in material science is crucial prior to considering AM as an acceptable method for the fabrication of dental prostheses.

  10. Current surgical practices in cleft care: cleft palate repair techniques and postoperative care.

    Science.gov (United States)

    Katzel, Evan B; Basile, Patrick; Koltz, Peter F; Marcus, Jeffrey R; Girotto, John A

    2009-09-01

    The purpose of this study was to objectively report practices commonly used in cleft palate repair in the United States. This study investigates current surgical techniques, postoperative care, and complication rates for cleft palate repair surgery. All 803 surgeon members of the American Cleft Palate-Craniofacial Association were sent online and/or paper surveys inquiring about their management of cleft palate patients. Three-hundred six surveys were received, a 38 percent response rate. This represented responses of surgeons from 100 percent of American Cleft Palate-Craniofacial Association registered cleft teams. Ninety-six percent of respondents perform a one-stage repair. Eighty-five percent of surgeons perform palate surgery when the patient is between 6 and 12 months of age. The most common one-stage repair techniques are the Bardach style (two flaps) with intravelar veloplasty and the Furlow palatoplasty. After surgery, 39 percent of surgeons discharge patients within 24 hours. Another 43 percent discharge patients within 48 hours. During postoperative management, 92 percent of respondents implement feeding restrictions. Eighty-five percent of physicians use arm restraints. Surgeons' self-reported complications rates are minimal: 54 percent report a fistula in less than 5 percent of cases. The reported need for secondary speech surgery varies widely. The majority of respondents repair clefts in one stage. The most frequently used repair techniques are the Furlow palatoplasty and the Bardach style with intravelar veloplasty. After surgery, the majority of surgeons discharge patients in 1 or 2 days, and nearly all surgeons implement feeding restrictions and the use of arm restraints. The varying feeding protocols are reviewed in this article.

  11. In-cylinder pressure-based direct techniques and time frequency analysis for combustion diagnostics in IC engines

    International Nuclear Information System (INIS)

    D’Ambrosio, S.; Ferrari, A.; Galleani, L.

    2015-01-01

    Highlights: • Direct pressure-based techniques have been applied successfully to spark-ignition engines. • The burned mass fraction of pressure-based techniques has been compared with that of 2- and 3-zone combustion models. • The time frequency analysis has been employed to simulate complex diesel combustion events. - Abstract: In-cylinder pressure measurement and analysis has historically been a key tool for off-line combustion diagnosis in internal combustion engines, but online applications for real-time condition monitoring and combustion management have recently become popular. The present investigation presents and compares different low computing-cost in-cylinder pressure based methods for the analyses of the main features of combustion, that is, the start of combustion, the end of combustion and the crankshaft angle that responds to half of the overall burned mass. The instantaneous pressure in the combustion chamber has been used as an input datum for the described analytical procedures and it has been measured by means of a standard piezoelectric transducer. Traditional pressure-based techniques have been shown to be able to predict the burned mass fraction time history more accurately in spark ignition engines than in diesel engines. The most suitable pressure-based techniques for both spark ignition and compression ignition engines have been chosen on the basis of the available experimental data. Time–frequency analysis has also been applied to the analysis of diesel combustion, which is richer in events than spark ignited combustion. Time frequency algorithms for the calculation of the mean instantaneous frequency are computationally efficient, allow the main events of the diesel combustion to be identified and provide the greatest benefits in the presence of multiple injection events. These algorithms can be optimized and applied to onboard diagnostics tools designed for real control, but can also be used as an advanced validation tool for

  12. Comparison of the Current Diagnostic Criterion of HbA1c with Fasting and 2-Hour Plasma Glucose Concentration

    Science.gov (United States)

    Karnchanasorn, Rudruidee; Huang, Jean; Feng, Wei; Chuang, Lee-Ming

    2016-01-01

    To determine the effectiveness of hemoglobin A1c (HbA1c) ≥ 6.5% in diagnosing diabetes compared to fasting plasma glucose (FPG) ≥ 126 mg/dL and 2-hour plasma glucose (2hPG) ≥ 200 mg/dL in a previously undiagnosed diabetic cohort, we included 5,764 adult subjects without established diabetes for whom HbA1c, FPG, 2hPG, and BMI measurements were collected. Compared to the FPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 43.3% (106 subjects). Compared to the 2hPG criterion, the sensitivity of HbA1c ≥ 6.5% was only 28.1% (110 subjects). Patients who were diabetic using 2hPG criterion but had HbA1c HbA1c ≥ 6.5%. The diagnostic agreement in the clinical setting revealed the current HbA1c ≥ 6.5% is less likely to detect diabetes than those defined by FPG and 2hPG. HbA1c ≥ 6.5% detects less than 50% of diabetic patients defined by FPG and less than 30% of diabetic patients defined by 2hPG. When the diagnosis of diabetes is in doubt by HbA1c, FPG and/or 2hPG should be obtained. PMID:27597979

  13. CpG Methylation Analysis—Current Status of Clinical Assays and Potential Applications in Molecular Diagnostics

    Science.gov (United States)

    Sepulveda, Antonia R.; Jones, Dan; Ogino, Shuji; Samowitz, Wade; Gulley, Margaret L.; Edwards, Robin; Levenson, Victor; Pratt, Victoria M.; Yang, Bin; Nafa, Khedoudja; Yan, Liying; Vitazka, Patrick

    2009-01-01

    Methylation of CpG islands in gene promoter regions is a major molecular mechanism of gene silencing and underlies both cancer development and progression. In molecular oncology, testing for the CpG methylation of tissue DNA has emerged as a clinically useful tool for tumor detection, outcome prediction, and treatment selection, as well as for assessing the efficacy of treatment with the use of demethylating agents and monitoring for tumor recurrence. In addition, because CpG methylation occurs early in pre-neoplastic tissues, methylation tests may be useful as markers of cancer risk in patients with either infectious or inflammatory conditions. The Methylation Working Group of the Clinical Practice Committee of the Association of Molecular Pathology has reviewed the current state of clinical testing in this area. We report here our summary of both the advantages and disadvantages of various methods, as well as the needs for standardization and reporting. We then conclude by summarizing the most promising areas for future clinical testing in cancer molecular diagnostics. PMID:19541921

  14. Fed-state gastric media and drug analysis techniques: Current status and points to consider.

    Science.gov (United States)

    Baxevanis, Fotios; Kuiper, Jesse; Fotaki, Nikoletta

    2016-10-01

    Gastric fed state conditions can have a significant effect on drug dissolution and absorption. In vitro dissolution tests with simple aqueous media cannot usually predict drugs' in vivo response, as several factors such as the meal content, the gastric emptying and possible interactions between food and drug formulations can affect drug's pharmacokinetics. Good understanding of the effect of the in vivo fed gastric conditions on the drug is essential for the development of biorelevant dissolution media simulating the gastric environment after the administration of the standard high fat meal proposed by the FDA and the EMA in bioavailability/bioequivalence (BA/BE) studies. The analysis of drugs in fed state media can be quite challenging as most analytical protocols currently employed are time consuming and labour intensive. In this review, an overview of the in vivo gastric conditions and the biorelevant media used for their in vitro simulation are described. Furthermore an analysis of the physicochemical properties of the drugs and the formulations related to food effect is given. In terms of drug analysis, the protocols currently used for the fed state media sample treatment and analysis and the analytical challenges and needs emerging for more efficient and time saving techniques for a broad spectrum of compounds are being discussed. Copyright © 2016 Elsevier B.V. All rights reserved.

  15. Robot-assisted pyeloplasty: review of the current literature, technique and outcome.

    Science.gov (United States)

    Singh, Iqbal; Hemal, Ashok K

    2010-04-01

    To review the global select data on the current technique, perioperative outcome and literature on the robot-assisted pyeloplasty (RAP). The published English literature (PubMed) was extensively searched using the key words; robot, robot-assisted pyeloplasty, laparoscopy, laparoscopic pyeloplasty and ureteropelvic junction obstruction. The selected studies were then reviewed, tracked and analyzed in order to determine the current role, outcome and status of robot-assisted laparoscopic pyeloplasty. The search yielded about 25 published series on RAP comprising about 740 cases with a mean operative time, estimated blood loss, crossing vessel prevalence, hospital stay,perioperative complication rate and follow up duration of 194 min, 50 mL, 47%, 2.3 days, 6% and 14.9 months respectively. The initial peri-operative results and intermediate follow up of cases of repair of the ureteropelvic junction obstruction with robot-assisted pyeloplasty appear to be favorable and comparable to that of open pyeloplasty, while long term outcome data is still awaited. The da Vinci surgical robotic system is a promising surgical armamentarium in the hands of the modern day urologist for the minimally invasive definitive surgical management of both primary and secondary ureteropelvic junction obstruction.

  16. Current calibration, treatment, and treatment planning techniques among institutions participating in the Children's Oncology Group

    International Nuclear Information System (INIS)

    Urie, Marcia; FitzGerald, T.J.; Followill, David; Laurie, Fran; Marcus, Robert; Michalski, Jeff

    2003-01-01

    Purpose: To report current technology implementation, radiation therapy physics and treatment planning practices, and results of treatment planning exercises among 261 institutions belonging to the Children's Oncology Group (COG). Methods and Materials: The Radiation Therapy Committee of the newly formed COG mandated that each institution demonstrate basic physics and treatment planning abilities by satisfactorily completing a questionnaire and four treatment planning exercises designed by the Quality Assurance Review Center. The planning cases are (1) a maxillary sinus target volume (for two-dimensional planning), (2) a Hodgkin's disease mantle field (for irregular-field and off-axis dose calculations), (3) a central axis blocked case, and (4) a craniospinal irradiation case. The questionnaire and treatment plans were submitted (as of 1/30/02) by 243 institutions and completed satisfactorily by 233. Data from this questionnaire and analyses of the treatment plans with monitor unit calculations are presented. Results: Of the 243 clinics responding, 54% use multileaf collimators routinely, 94% use asymmetric jaws routinely, and 13% use dynamic wedges. Nearly all institutions calibrate their linear accelerators following American Association of Physicists in Medicine protocols, currently 16% with TG-51 and 81% with TG-21 protocol. Treatment planning systems are relied on very heavily for all calculations, including monitor units. Techniques and results of each of the treatment planning exercises are presented. Conclusions: Together, these data provide a unique compilation of current (2001) radiation therapy practices in institutions treating pediatric patients. Overall, the COG facilities have the equipment and the personnel to perform high-quality radiation therapy. With ongoing quality assurance review, radiation therapy compliance with COG protocols should be high

  17. Diagnostic techniques for viroids

    Czech Academy of Sciences Publication Activity Database

    Gucek, T.; Trdan, S.; Jakše, J.; Javornik, B.; Matoušek, Jaroslav; Radisek, S.

    2017-01-01

    Roč. 66, č. 3 (2017), s. 339-358 ISSN 0032-0862 Institutional support: RVO:60077344 Keywords : potato-spindle-tuber * multiplex rt-pcr * mediated isothermal amplification Subject RIV: EE - Microbiology, Virology OBOR OECD: Biochemistry and molecular biology Impact factor: 2.425, year: 2016

  18. XII All-Russian conference Diagnostics of high-temperature plasma. Abstracts of reports and conference program

    International Nuclear Information System (INIS)

    2007-01-01

    Abstracts of reports made on the XII All-Russian conference on high-temperature plasma diagnostics are presented. The different methods of hot plasma diagnostics are considered, namely microwave diagnostic methods, laser diagnostic techniques, X-ray plasma diagnostics and corpuscular diagnostic methods. The particular attention is given to wall plasma diagnostics and diagnostics of inertial synthesis systems. Current diagnostic tools and metrological provision for plasma diagnostics are considered. The diagnostic complexes of thermonuclear devices are described. The problems of experimental data processing are discussed [ru

  19. Non destructive technique for cracks detection by an eddy current in differential mode for steel frames

    International Nuclear Information System (INIS)

    Harzalla, S.; Chabaat, M.; Belgacem, F. Bin Muhammad

    2014-01-01

    In this paper, a nondestructive technique is used as a tool to control cracks and microcracks in materials. A simulation by a numerical approach such as the finite element method is employed to detect cracks and eventually; to study their propagation using a crucial parameter such as the stress intensity factor. This approach has been used in the aircraft industry to control cracks. Besides, it makes it possible to highlight the defects of parts while preserving the integrity of the controlled products. On the other side, it is proven that the reliability of the control of defects gives convincing results for the improvement of the quality and the safety of the material. Eddy current testing (ECT) is a standard technique in industry for the detection of surface breaking flaws in magnetic materials such as steels. In this context, simulation tools can be used to improve the understanding of experimental signals, optimize the design of sensors or evaluate the performance of ECT procedures. CEA-LIST has developed for many years semi-analytical models embedded into the simulation platform CIVA dedicated to non-destructive testing. The developments presented herein address the case of flaws located inside a planar and magnetic medium. Simulation results are obtained through the application of the Volume Integral Method (VIM). When considering the ECT of a single flaw, a system of two differential equations is derived from Maxwell equations. The numerical resolution of the system is carried out using the classical Galerkin variant of the Method of Moments. Besides, a probe response is calculated by application of the Lorentz reciprocity theorem. Finally, the approach itself as well as comparisons between simulation results and measured data are presented

  20. Current updates on laboratory techniques for the diagnosis of male reproductive failure

    Directory of Open Access Journals (Sweden)

    Suresh C Sikka

    2016-01-01

    Full Text Available The incidence of male reproductive failure leading to infertility, whether due to delayed parenthood, environmental issues, genetic factors, drugs, etc., is increasing throughout the world. The diagnosis and prognosis of male subfertility have become a challenge. While the basic semen assessment has been performed for many years, a number of studies question the value of the traditional semen characteristics. This is partly due to inadequate methods and standardization, limited knowledge of technical requirements for quality assurance, and an incomplete understanding of what clinical information a semen assessment can provide. Laboratories currently performing semen and endocrine assessment show great variability. The World Health Organization (WHO manual for the evaluation of semen has been the core of andrology and fertility evaluation that has helped in further development of this field over many years. These include the physical appearance of the ejaculate, assessments of sperm count, motility, vitality, morphology, and functional aspects of the sperm and semen sample. These tests also include male endocrine profile, biochemical evaluation of the semen, detection of antisperm antibodies in serum, the use of computer-aided sperm analysis (CASA, sperm DNA integrity, and its damage due to oxidative stress. Assisted reproductive techniques (e.g., IVF, ICSI have shown great success but are too expensive. Further development in this field with newer techniques and extensive training/instructions can improve accuracy and reduce variability, thus maintaining the quality and standards of such an evaluation. There is an urgent need to have standardized training centers and increased awareness in this area of men′s health for reproductive success.

  1. Laparoscopic major hepatectomies: current trends and indications. A comparison with the open technique.

    Science.gov (United States)

    Ratti, Francesca; Cipriani, Federica; Ariotti, Riccardo; Giannone, Fabio; Paganelli, Michele; Aldrighetti, Luca

    2015-06-01

    Diffusion of laparoscopic major hepatectomies is experiencing a steady increasing trend, although slower compared to minor resections. The aim of this single-center study is to discuss current trends and indications in the application of minimally invasive techniques to major hepatic resections. Preoperative patients and disease characteristics of 49 laparoscopic major hepatectomies (LPS group), performed between 2005 and 2015, were compared with 585 open hepatectomies (Open group) to analyze differences in patients recruitment. Factors which were found to be differently distributed between groups were used as covariates in a propensity score-based case-matched analysis with a 1:3 ratio between LPS group and 147 patients from the Open group (constituting Open-mat group). Short-term outcome was analyzed in matched groups. ASA score, previous abdominal surgery, previous interventional procedures, indication, lesion size and associated procedures were significantly different between the LPS and the Open group. Short-term outcome analysis revealed that blood loss (200 vs 350 mL, p = 0.044) and time for functional recovery (3 vs 4 days, p = 0.05) were reduced in the LPS compared to the Open-mat group, in spite of longer length of surgery (260 vs 170 min, p = 0.041) and comparable oncological adequacy. Even though data on technical feasibility of laparoscopic major resections and their benefits in terms of blood loss and functional recovery support the diffusion of minimally invasive approach, the limit of the technique is still represented by the reduced pool of suitable candidates.

  2. Non destructive technique for cracks detection by an eddy current in differential mode for steel frames

    Energy Technology Data Exchange (ETDEWEB)

    Harzalla, S., E-mail: harzallahozil@yahoo.fr; Chabaat, M., E-mail: mchabaat@yahoo.com [Built Environmental Research Laboratory, Civil Engineering Faculty, University of Sciences and Technology Houari Boumediene, B.P. 32 El Alia Bab-Ezzouar, Algiers 16111 (Algeria); Belgacem, F. Bin Muhammad, E-mail: fbmbelgacem@gmail.com [Department of Mathematics, Faculty of Basic Education, PAAET, Al-Aardhia (Kuwait)

    2014-12-10

    In this paper, a nondestructive technique is used as a tool to control cracks and microcracks in materials. A simulation by a numerical approach such as the finite element method is employed to detect cracks and eventually; to study their propagation using a crucial parameter such as the stress intensity factor. This approach has been used in the aircraft industry to control cracks. Besides, it makes it possible to highlight the defects of parts while preserving the integrity of the controlled products. On the other side, it is proven that the reliability of the control of defects gives convincing results for the improvement of the quality and the safety of the material. Eddy current testing (ECT) is a standard technique in industry for the detection of surface breaking flaws in magnetic materials such as steels. In this context, simulation tools can be used to improve the understanding of experimental signals, optimize the design of sensors or evaluate the performance of ECT procedures. CEA-LIST has developed for many years semi-analytical models embedded into the simulation platform CIVA dedicated to non-destructive testing. The developments presented herein address the case of flaws located inside a planar and magnetic medium. Simulation results are obtained through the application of the Volume Integral Method (VIM). When considering the ECT of a single flaw, a system of two differential equations is derived from Maxwell equations. The numerical resolution of the system is carried out using the classical Galerkin variant of the Method of Moments. Besides, a probe response is calculated by application of the Lorentz reciprocity theorem. Finally, the approach itself as well as comparisons between simulation results and measured data are presented.

  3. Comparison of four diagnostic techniques for detection of Trichomonas vaginalis infection in females attending tertiary care hospital of North India

    Directory of Open Access Journals (Sweden)

    Razia Khatoon

    2015-01-01

    Full Text Available Background: Trichomonas vaginalis causes a common sexually transmitted disease trichomoniasis, which may lead to increased risk of transmission of human immunodeficiency virus infection and other pelvic inflammatory diseases. Wet mount examination is the most common test for diagnosis, but it has low sensitivity. Acridine orange staining can be used for diagnosis, but it requires special microscopic facility. Culture is considered as the gold standard, but it takes a long time for diagnosis. OSOM Trichomonas Rapid Test is a recently introduced rapid method based on immunochromatographic assay of trichomonal protein antigens. Hence, the present study was done to compare these four diagnostic techniques for detection of trichomoniasis in females with vaginal discharge. Materials and Methods: Vaginal swabs were taken from 835 female patients and wet mount examination, acridine orange staining, culture in Kupferberg medium, and OSOM Trichomonas Rapid Test, were performed. Results: Out of 835 patients included in our study, 68 (8.1% positive cases of trichomoniasis were detected by culture. OSOM Trichomonas Rapid Test detected 63 (7.5% cases, acridine orange staining detected 53 (6.3% cases, whereas, wet mount examination detected only 45 (5.4% positive cases. OSOM Trichomonas Rapid Test performed well and showed high sensitivity and specificity of 88.2% and 99.6%, respectively. Conclusion: As OSOM Trichomonas Rapid Test is a point of care test and gave better results than both wet mount examination and acridine orange staining; it can be used as a routine test in peripheral areas lacking laboratory facilities.

  4. Discrimination of Inrush from Fault Currents in Power Transformers Based on Equivalent Instantaneous Inductance Technique Coupled with Finite Element Method

    Directory of Open Access Journals (Sweden)

    M. Jamali

    2011-09-01

    Full Text Available The phenomenon of magnetizing inrush is a transient condition, which occurs primarily when a transformer is energized. The magnitude of inrush current may be as high as ten times or more times of transformer rated current that causes malfunction of protection system. So, for safe running of a transformer, it is necessary to distinguish inrush current from fault currents. In this paper, an equivalent instantaneous inductance (EII technique is used to discriminate inrush current from fault currents. For this purpose, a three-phase power transformer has been simulated in Maxwell software that is based on finite elements. This three-phase power transformer has been used to simulate different conditions. Then, the results have been used as inputs in MATLAB program to implement the equivalent instantaneous inductance technique. The results show that in the case of inrush current, the equivalent instantaneous inductance has a drastic variation, while it is almost constant in the cases of fault conditions.

  5. Refractive error assessment: influence of different optical elements and current limits of biometric techniques.

    Science.gov (United States)

    Ribeiro, Filomena; Castanheira-Dinis, Antonio; Dias, Joao Mendanha

    2013-03-01

    To identify and quantify sources of error on refractive assessment using exact ray tracing. The Liou-Brennan eye model was used as a starting point and its parameters were varied individually within a physiological range. The contribution of each parameter to refractive error was assessed using linear regression curve fits and Gaussian error propagation analysis. A MonteCarlo analysis quantified the limits of refractive assessment given by current biometric measurements. Vitreous and aqueous refractive indices are the elements that influence refractive error the most, with a 1% change of each parameter contributing to a refractive error variation of +1.60 and -1.30 diopters (D), respectively. In the phakic eye, axial length measurements taken by ultrasound (vitreous chamber depth, lens thickness, and anterior chamber depth [ACD]) were the most sensitive to biometric errors, with a contribution to the refractive error of 62.7%, 14.2%, and 10.7%, respectively. In the pseudophakic eye, vitreous chamber depth showed the highest contribution at 53.7%, followed by postoperative ACD at 35.7%. When optic measurements were considered, postoperative ACD was the most important contributor, followed by anterior corneal surface and its asphericity. A MonteCarlo simulation showed that current limits of refractive assessment are 0.26 and 0.28 D for the phakic and pseudophakic eye, respectively. The most relevant optical elements either do not have available measurement instruments or the existing instruments still need to improve their accuracy. Ray tracing can be used as an optical assessment technique, and may be the correct path for future personalized refractive assessment. Copyright 2013, SLACK Incorporated.

  6. Brachytherapy, diagnostic radiology, mammographic radiology and ophthalmic applicators. An assessment of current and future needs in the UK and the role of NPL

    International Nuclear Information System (INIS)

    Angliss, R.; Bass, G.; Sander, T.

    2001-01-01

    Several UK hospitals were visited by NPL staff to discuss the current practises and future developments in brachytherapy, diagnostic and mammographic radiology and ophthalmic applicators. The results of the discussions are presented here, including NPL's role in each of these areas is discussed. (author)

  7. Lot quality assurance sampling techniques in health surveys in developing countries: advantages and current constraints.

    Science.gov (United States)

    Lanata, C F; Black, R E

    1991-01-01

    Traditional survey methods, which are generally costly and time-consuming, usually provide information at the regional or national level only. The utilization of lot quality assurance sampling (LQAS) methodology, developed in industry for quality control, makes it possible to use small sample sizes when conducting surveys in small geographical or population-based areas (lots). This article describes the practical use of LQAS for conducting health surveys to monitor health programmes in developing countries. Following a brief description of the method, the article explains how to build a sample frame and conduct the sampling to apply LQAS under field conditions. A detailed description of the procedure for selecting a sampling unit to monitor the health programme and a sample size is given. The sampling schemes utilizing LQAS applicable to health surveys, such as simple- and double-sampling schemes, are discussed. The interpretation of the survey results and the planning of subsequent rounds of LQAS surveys are also discussed. When describing the applicability of LQAS in health surveys in developing countries, the article considers current limitations for its use by health planners in charge of health programmes, and suggests ways to overcome these limitations through future research. It is hoped that with increasing attention being given to industrial sampling plans in general, and LQAS in particular, their utilization to monitor health programmes will provide health planners in developing countries with powerful techniques to help them achieve their health programme targets.

  8. Current practice in laboratory diagnostics of autoimmune diseases in Croatia. 
Survey of the Working group for laboratory diagnostics of autoimmune diseases of the Croatian Society of Medical Biochemistry and Laboratory Medicine.

    Science.gov (United States)

    Kuna, Andrea Tešija; Đerek, Lovorka; Kozmar, Ana; Drvar, Vedrana

    2016-10-15

    With the trend of increasing incidence of autoimmune diseases, laboratories are faced with exponential growth of the requests for tests relating the diagnosis of these diseases. Unfortunately, the lack of laboratory personnel experienced in this specific discipline of laboratory diagnostic, as well as an unawareness of a method limitation often results in confusion for clinicians. The aim was to gain insight into number and type of Croatian laboratories that perform humoral diagnostics with the final goal to improve and harmonize laboratory diagnostics of autoimmune diseases in Croatia. In order to get insight into current laboratory practice two questionnaires, consisting of 42 questions in total, were created. Surveys were conducted using SurveyMonkey application and were sent to 88 medical biochemistry laboratories in Croatia for the first survey. Out of 33 laboratories that declared to perform diagnostic from the scope, 19 were selected for the second survey based on the tests they pleaded to perform. The survey comprised questions regarding autoantibody hallmarks of systemic autoimmune diseases while regarding organ-specific autoimmune diseases was limited to diseases of liver, gastrointestinal and nervous system. Response rate was high with 80 / 88 (91%) laboratories which answered the first questionnaire, and 19 / 19 (1.0) for the second questionnaire. Obtained results of surveys indicate high heterogeneity in the performance of autoantibody testing among laboratories in Croatia. Results indicate the need of creating recommendations and algorithms in order to harmonize the approach to laboratory diagnostics of autoimmune diseases in Croatia.

  9. Computation of large scale currents in the Arabian Sea during winter using a semi-diagnostic model

    Digital Repository Service at National Institute of Oceanography (India)

    Shaji, C.; Bahulayan, N.; Rao, A.D.; Dube, S.K.

    A 3-dimensional, semi-diagnostic model with 331 levels in the vertical has been used for the computation of climatic circulation in the western tropical Indian Ocean. Model is driven with the seasonal mean data on wind stress, temperature...

  10. An assessment of the 3D geometric surrogacy of shock timing diagnostic techniques for tuning experiments on the NIF

    Energy Technology Data Exchange (ETDEWEB)

    Robey, H F; Munro, D H; Spears, B K; Marinak, M M; Jones, O S; Patel, M V; Haan, S W; Salmonson, J D; Landen, O L [Lawrence Livermore National Laboratory, Livermore, CA (United States); Boehly, T R [Laboratory for Laser Energetics, Rochester, NY (United States); Nikroo, A [General Atomics, San Diego, CA (United States)], E-mail: robey1@llnl.gov

    2008-05-15

    Ignition capsule implosions planned for the National Ignition Facility (NIF) require a pulse shape with a carefully designed series of four steps, which launch a corresponding series of shocks through the ablator and DT ice shell. The relative timing of these shocks is critical for maintaining the DT fuel on a low adiabat. The current NIF specification requires that the timing of all four shocks be tuned to an accuracy of {<=} +/- 100ps. To meet these stringent requirements, dedicated tuning experiments are being planned to measure and adjust the shock timing on NIF. These tuning experiments will be performed in a modified hohlraum geometry, where a re-entrant Au cone is added to the standard NIF hohlraum to provide optical diagnostic (VISAR and SOP) access to the shocks as they break out of the ablator. This modified geometry is referred to as the 'keyhole' hohlraum and introduces a geometric difference between these tuning-experiments and the full ignition geometry. In order to assess the surrogacy of this modified geometry, 3D simulations using HYDRA [1] have been performed. The results from simulations of a quarter of the target geometry are presented. Comparisons of the hohlraum drive conditions and the resulting effect on the shock timing in the keyhole hohlraum are compared with the corresponding results for the standard ignition hohlraum.

  11. An assessment of the 3D geometric surrogacy of shock timing diagnostic techniques for tuning experiments on the NIF

    International Nuclear Information System (INIS)

    Robey, H F; Munro, D H; Spears, B K; Marinak, M M; Jones, O S; Patel, M V; Haan, S W; Salmonson, J D; Landen, O L; Boehly, T R; Nikroo, A

    2008-01-01

    Ignition capsule implosions planned for the National Ignition Facility (NIF) require a pulse shape with a carefully designed series of four steps, which launch a corresponding series of shocks through the ablator and DT ice shell. The relative timing of these shocks is critical for maintaining the DT fuel on a low adiabat. The current NIF specification requires that the timing of all four shocks be tuned to an accuracy of ≤ +/- 100ps. To meet these stringent requirements, dedicated tuning experiments are being planned to measure and adjust the shock timing on NIF. These tuning experiments will be performed in a modified hohlraum geometry, where a re-entrant Au cone is added to the standard NIF hohlraum to provide optical diagnostic (VISAR and SOP) access to the shocks as they break out of the ablator. This modified geometry is referred to as the 'keyhole' hohlraum and introduces a geometric difference between these tuning-experiments and the full ignition geometry. In order to assess the surrogacy of this modified geometry, 3D simulations using HYDRA [1] have been performed. The results from simulations of a quarter of the target geometry are presented. Comparisons of the hohlraum drive conditions and the resulting effect on the shock timing in the keyhole hohlraum are compared with the corresponding results for the standard ignition hohlraum

  12. A Review of Current Machine Learning Techniques Used in Manufacturing Diagnosis

    OpenAIRE

    Ademujimi , Toyosi ,; Brundage , Michael ,; Prabhu , Vittaldas ,

    2017-01-01

    Part 6: Intelligent Diagnostics and Maintenance Solutions; International audience; Artificial intelligence applications are increasing due to advances in data collection systems, algorithms, and affordability of computing power. Within the manufacturing industry, machine learning algorithms are often used for improving manufacturing system fault diagnosis. This study focuses on a review of recent fault diagnosis applications in manufacturing that are based on several prominent machine learnin...

  13. Molecular Diagnostics

    OpenAIRE

    Choe, Hyonmin; Deirmengian, Carl A.; Hickok, Noreen J.; Morrison, Tiffany N.; Tuan, Rocky S.

    2015-01-01

    Orthopaedic infections are complex conditions that require immediate diagnosis and accurate identification of the causative organisms to facilitate appropriate management. Conventional methodologies for diagnosis of these infections sometimes lack accuracy or sufficient rapidity. Current molecular diagnostics are an emerging area of bench-to-bedside research in orthopaedic infections. Examples of promising molecular diagnostics include measurement of a specific biomarker in the synovial fluid...

  14. Measuring the corrosion rate of steel in concrete – effect of measurement technique, polarisation time and current

    DEFF Research Database (Denmark)

    Nygaard, Peter Vagn; Geiker, Mette Rica

    2012-01-01

    , are in some studies considered the main reasons for the variations. This paper presents an experimental study on the quantitative effect of polarisation time and current on the measured polarisation resistance – and thus the corrosion current density – of passively and actively corroding steel. Two...... electrochemical techniques often used in instruments for on-site corrosion rate measurements are investigated. On passively corroding reinforcement the measured polarisation resistance was for both techniques found to be highly affected by the polarisation time and current and no plateaus at either short or long...... rate for actively corroding steel. For both techniques guidelines for polarisation times and currents are given for (on-site) non-destructive corrosion rate measurements on reinforcement steel in concrete....

  15. The knee meniscus: structure-function, pathophysiology, current repair techniques, and prospects for regeneration

    Science.gov (United States)

    Makris, Eleftherios A.; Hadidi, Pasha; Athanasiou, Kyriacos A.

    2011-01-01

    Extensive scientific investigations in recent decades have established the anatomical, biomechanical, and functional importance that the meniscus holds within the knee joint. As a vital part of the joint, it acts to prevent the deterioration and degeneration of articular cartilage, and the onset and development of osteoarthritis. For this reason, research into meniscus repair has been the recipient of particular interest from the orthopedic and bioengineering communities. Current repair techniques are only effective in treating lesions located in the peripheral vascularized region of the meniscus. Healing lesions found in the inner avascular region, which functions under a highly demanding mechanical environment, is considered to be a significant challenge. An adequate treatment approach has yet to be established, though many attempts have been undertaken. The current primary method for treatment is partial meniscectomy, which commonly results in the progressive development of osteoarthritis. This drawback has shifted research interest towards the fields of biomaterials and bioengineering, where it is hoped that meniscal deterioration can be tackled with the help of tissue engineering. So far, different approaches and strategies have contributed to the in vitro generation of meniscus constructs, which are capable of restoring meniscal lesions to some extent, both functionally as well as anatomically. The selection of the appropriate cell source (autologous, allogeneic, or xenogeneic cells, or stem cells) is undoubtedly regarded as key to successful meniscal tissue engineering. Furthermore, a large variation of scaffolds for tissue engineering have been proposed and produced in experimental and clinical studies, although a few problems with these (e.g., byproducts of degradation, stress shielding) have shifted research interest towards new strategies (e.g., scaffoldless approaches, self-assembly). A large number of different chemical (e.g., TGF-β1, C-ABC) and

  16. Current Techniques of Teaching and Learning in Bariatric Surgical Procedures: A Systematic Review.

    Science.gov (United States)

    Kaijser, Mirjam; van Ramshorst, Gabrielle; van Wagensveld, Bart; Pierie, Jean-Pierre

    The gastric sleeve resection and gastric bypass are the 2 most commonly performed bariatric procedures. This article provides an overview of current teaching and learning methods of those techniques in resident and fellow training. A database search was performed on Pubmed, Embase, and the Education Resources Information Center (ERIC) to identify the methods used to provide training in bariatric surgery worldwide. After exclusion based on titles and abstracts, full texts of the selected articles were assessed. Included articles were reviewed using the Grading of Recommendations Assessment, Development and Evaluation (GRADE) system. In total, 2442 titles were identified and 14 full text articles met inclusion criteria. Four publications described an ex vivo training course, and 6 focused on at least 1 step of the gastric bypass procedure. Two randomized controlled trials (RCT) provided high-quality evidence on training aspects. Surgical coaching caused significant improvement of Bariatric Objective Structured Assessment of Technical Skills (BOSATS) scores (3.60 vs. 3.90, p = 0.017) and reduction of technical errors (18 vs. 10, p = 0.003). A preoperative warm-up increased global rating scales (GRS) scores on depth perception (p = 0.02), bimanual dexterity (p = 0.01), and efficiency of movements (p = 0.03). Stepwise education, surgical coaching, warming up, Internet-based knowledge modules, and ex vivo training courses are effective in relation to bariatric surgical training of residents and fellows, possibly shortening their learning curves. Copyright © 2018 Association of Program Directors in Surgery. Published by Elsevier Inc. All rights reserved.

  17. Annular gap measurement between pressure tube and calandria tube by eddy current technique

    International Nuclear Information System (INIS)

    Bhole, V.M.; Rastogi, P.K.; Kulkarni, P.G.

    1992-01-01

    In pressurised heavy water reactor (PHWR) major distinguishing feature is that there are number of identical fuel channels in the reactor core. Each channel consists of pressure tube of Zr-2.5 Nb or zircaloy-2 through which high temperature, high pressure primary coolant is passing. The pressure tube contains fuel. Surrounding the pressure tube there is low pressure, cool heavy water (moderator). The moderator is thermally separated from coolant by the tube which is nominally concentric with pressure tube called calandria tube. There are four garter springs in the annular gap between pressure tube and calandria tube. During the life of the reactor there are number of factors by which the pressure tube sags, most important factors are irradiation creep, thermal creep, fuel load etc. Because of the sag of pressure tube it can touch the calandria tube resulting in formation of cold spot. This leads to hydrogen concentration at that spot by which the material at that place becomes brittle and can lead to catastrophic failure of pressure tube. There is no useful access for measurement of annular gap either through the gas annular space or from exterior of calandria tube. So the annular gap was measured from inside surface of pressure tube which is accessible. Eddy current technique was used for finding the gap. The paper describe the details of split coil design of bobbin probe, selection of operating point on normalised impedance diagram by choosing frequency. Experimental results on full scale mock up, and actual gap measurement in reactor channel, are also given. (author). 7 figs

  18. Current aspects in the development of the quality control in the conventional X-ray diagnostic radiology

    International Nuclear Information System (INIS)

    Stoeva, M.; Velkova, K.

    2004-01-01

    The role of the X-ray diagnostic radiology as one of the main factors forming the general public dose is indisputable. Following the requirement for justification of the application of X-rays for medical purposes, certain criteria for assessment of the parameters of the X-ray diagnostic equipment are formed and maximum permissible values defined. The latter are developed by the international and national radiation protection organizations and introduced both in the international and national legislation. The importance of the quality assurance concept for the radiation protection of the patient and staff in diagnostic radiology turned the quality control into main toll for obtaining high quality images with minimum dose to the patient and staff. X-ray diagnostics is one of the most common methods used in the medical practice. This is the main reason for the increase of the quality control protocols, winch makes their handling difficult. The latest developments in this area bring forward the idea for the development of specialized quality control software, which is capable of: 1) full or semi-automated calculation and assessment of the parameters of the X-ray diagnostic units; 2) tools for data handling and access; 3) tools for data analysis based on predefined procedures

  19. Imaging technique and current status of valvular heart disease using cardiac MRI

    International Nuclear Information System (INIS)

    Lotz, J.; Sohns, J.M.

    2013-01-01

    The main indications for cardiac magnetic resonance imaging (MRI) in the evaluation of valvular heart disease are pathologies of the aortic and pulmonary valve. For mitral and tricuspid valve pathologies MRI is not the first line modality as these are usually well visualized by echocardiography. The advantages of MRI in valvular heart disease are a high reliability in the evaluation of ventricular volumes and function as well as the assessment of the perivalvular arterial or atrial structures. This reliability and the limitless access to any imaging plane partially compensates for the lower temporal and spatial resolution in comparison to echocardiography. In patients with congenital heart disease, cardiac MRI is established as a valuable diagnostic tool in daily clinical management, especially for the evaluation of pulmonary valve defects. Nevertheless, echocardiography remains the first-line diagnostic imaging tool for the foreseeable future. (orig.) [de

  20. Diagnostic techniques for measuring temperature transients and stress transients in the first wall of an ICF reactor

    International Nuclear Information System (INIS)

    Melamed, N.T.; Taylor, L.H.

    1983-01-01

    The primary challenge in the design of an Inertial Confinement Fusion (ICF) power reactor is to make the first wall survive the frequent explosions of the pellets. Westinghouse has proposed a dry wall design consisting of steel tubes coated with tantalum. This report describes the design of a test chamber and two diagnostic procedures for experimentally determining the reliability of the Westinghouse design. The test chamber simulates the x-ray and ion pulse irradiation of the wall due to a pellet explosion. The diagnostics consist of remote temperature sensing and surface deformation measurements. The chamber and diagnostics can also be used to test other first-wall designs