  1. A ZVS PWM control strategy with balanced capacitor current for half-bridge three-level DC/DC converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Chen, Zhe

    2017-01-01

    PWM strategy, which can eliminate the current imbalance among the two input capacitors. Therefore, the proposed control strategy can improve the converter's performance and reliability in: 1) reducing the switching losses and noises of the power switches; 2) balancing the thermal stresses...

  2. Hybrid zero-voltage switching (ZVS) control for power inverters

    Energy Technology Data Exchange (ETDEWEB)

    Amirahmadi, Ahmadreza; Hu, Haibing; Batarseh, Issa

    2016-11-01

    A power inverter combination includes a half-bridge power inverter including first and second semiconductor power switches receiving input power having an intermediate node therebetween providing an inductor current through an inductor. A controller includes input comparison circuitry receiving the inductor current having outputs coupled to first inputs of pulse width modulation (PWM) generation circuitry, and a predictive control block having an output coupled to second inputs of the PWM generation circuitry. The predictive control block is coupled to receive a measure of Vin and an output voltage at a grid connection point. A memory stores a current control algorithm configured for resetting a PWM period for a switching signal applied to control nodes of the first and second power switch whenever the inductor current reaches a predetermined upper limit or a predetermined lower limit.

  3. Commutation Processes in Multiresonant ZVS Bridge Converter

    Directory of Open Access Journals (Sweden)

    Miroslaw Luft

    2008-01-01

    Full Text Available The analysis of the multiresonant ZVS DC/DC bridge converter is presented. The control system of the converter is basedon the method of frequency control at the constant time of transistor turn-off with a phase shift. The operation of the circuit is givenand the operating range of the converter is defined where ZVS switching operation is assured. Control characteristics are given andthe converter’s efficiency is defined. The circuit’s operation is analysed on the basis of results of the converter simulation tests using Simplorer programme.

  4. Li-Po Battery Charger Based on the Constant Current/Voltage Parallel Resonant Converter Operating in ZVS

    Directory of Open Access Journals (Sweden)

    Alberto M. Pernía

    2018-04-01

    Full Text Available Battery requirements for electrical vehicles are continuously becoming more demanding in terms of energy density and reliability. Nowadays, batteries for drones must be able to supply 100 A for 15 min, not to mention the specifications required for batteries in electrical vehicles. These specifications result in more stringent specifications for battery chargers. They are required to be more efficient, flexible, and, as with any another power equipment, to have reduced size and weight. Since the parallel resonant converter can operate as a current source and as a voltage source, this paper presents a battery charger power stage for lithium ion polymer batteries, based on the above topology, operating in zero voltage switching mode, and implementing frequency and duty cycle control.

  5. Zero-Voltage Switching PWM Strategy Based Capacitor Current-Balancing Control for Half-Bridge Three-Level DC/DC Converter

    DEFF Research Database (Denmark)

    Liu, Dong; Deng, Fujin; Zhang, Qi

    2018-01-01

    The current imbalance among the two input capacitors is one of the important issues of the half-bridge threelevel (HBTL) DC/DC converter, which would affect system performance and reliability. In this paper, a zero-voltage switching (ZVS) pulse-wide modulation (PWM) strategy including two operation...... modes is proposed. Based on the proposed ZVS PWM strategy, a capacitor current-balancing control is proposed for the HBTL DC/DC converter, where the currents on the two input capacitors can be kept balanced by alternating the two operation modes of the proposed ZVS PWM strategy. Therefore, the proposed...... control strategy can improve the performance and reliability of the converter in the aspect of balancing the thermal stresses and lifetimes among the two input capacitors. Finally, simulation and experimental studies are conducted and results verify the proposed control strategy....

  6. High Efficiency Interleaved Bi-Directional ZVS DC-DC Converter

    DEFF Research Database (Denmark)

    Zafar Ullah Khan, M.; Mohsin Naveed, M.; Hussain, Dil Muhammad Akbar

    2013-01-01

    A High Efficiency Interleaved Bi-Directional ZVS DC-DC converter is presented in this paper. This converter can be operated in both buck and boost mode. CoolMOS is used as a power device to achieve low conduction losses and fast turn off. The value of inductance is selected such that the Cool......MOS drain-to-source voltage always falls to zero before it turns on and ZVS is achieved. Multiphase interleaved inductors are used to achieve high power and low ripple currents. Converter is operated at 50kHz and MATLAB Simulink simulation is performed. 6kW prototype converter is implemented in buck mode...

  7. An Improved Current-Doubler Rectifier for the Marine Controlled Source Electromagnetic Transmitter

    Directory of Open Access Journals (Sweden)

    Hongxi Song

    2018-01-01

    Full Text Available High power marine controlled source electromagnetic transmitters have gained interest with applications in marine geological survey and mineral resources exploration. The direct current to direct current (DC-DC converter that is typically used in marine transmitters has some issues, as the insulated-gate bipolar transistor (IGBT tube cannot achieve zero-voltage switching (ZVS. In particular, lagging-leg switching cannot easily achieve ZVS. The conversion efficiency of the heat converter requires improvement. This paper proposes an improved current-doubler rectifier for the marine controlled source electromagnetic transmitter (ICDR-MCSET. Resonant inductance is increased and a blocking capacitor is added to the converter (DC-DC circuit, where the converter can achieve ZVS in a wide load range. This results in the effective decrease of the heating temperature and the improvement of transformation efficiency. Saber software simulation and a 20 KW electromagnetic transmitter are used to verify the results, which show that the method is feasible and effective.

  8. Superconducting fault current controller/current controller

    Science.gov (United States)

    Cha, Yung S.

    2004-06-15

    A superconducting fault current controller/current controller employs a superconducting-shielded core reactor (SSCR) with a variable impedance in a secondary circuit to control current in a primary circuit such as an electrical distribution system. In a second embodiment, a variable current source is employed in a secondary circuit of an SSCR to control current in the primary circuit. In a third embodiment, both a variable impedance in one secondary circuit and a variable current source in a second circuit of an SSCR are employed for separate and independent control of current in the primary circuit.

  9. Verification of Positional Accuracy of ZVS3003 Geodetic Control ...

    African Journals Online (AJOL)

    The International GPS Service (IGS) has provided GPS orbit products to the scientific community with increased precision and timeliness. Many users interested in geodetic positioning have adopted the IGS precise orbits to achieve centimeter level accuracy and ensure long-term reference frame stability. Positioning with ...

  10. Digital Simulation of Closed Loop Zvs-Zcs Bidirectional Dc-Dc Converter for Fuel Cell and Battery Application

    Directory of Open Access Journals (Sweden)

    V. V. Subrahmanya Kumar Bhajana

    2010-08-01

    Full Text Available A closed loop ZVS-ZCS bidirectional dc-dc converter is modeled and appropriate digital simulations are provided. With the ZVS-ZCS concept, the MATLAB simulation results of application to a fuel cell and battery application have been obtained whenever the input voltage exceeds the given 24V, at that time the load voltage will change from 180V to 230V. But due to this usage the load is disturbed and there is instability in the model. Using closed loop the output voltage is stabilized.

  11. A novel ZVS high voltage power supply for micro-channel plate photomultiplier tubes

    Energy Technology Data Exchange (ETDEWEB)

    Pei, Chengquan [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Tian, Jinshou [Xi’an Institute of Optics and Precision Mechanics, Chinese Academy of Sciences, Xi' an 710119 (China); Liu, Zhen [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China); Qin, Hong [School of Computer Science and Technology, Xi' an University of Science and Technology, Xi' an 710054 (China); Wu, Shengli, E-mail: slwu@mail.xjtu.edu.cn [Key Laboratory for Physical Electronics and Devices of the Ministry of Education, Xi' an Jiaotong University, Xi’an 710049 (China)

    2017-04-11

    A novel resonant high voltage power supply (HVPS) with zero voltage switching (ZVS), to reduce the voltage stress on switching devices and improve conversion efficiency, is proposed. The proposed HVPS includes a drive circuit, a transformer, several voltage multiplying circuits, and a regulator circuit. The HVPS contains several secondary windings that can be precisely regulated. The proposed HVPS performed better than the traditional resistor voltage divider, which requires replacing matching resistors resulting in resistor dispersibility in the Micro-Channel Plate (MCP). The equivalent circuit of the proposed HVPS was established and the operational principle analyzed. The entire switching element can achieve ZVS, which was validated by a simulation and experiments. The properties of this HVPS were tested including minimum power loss (240 mW), maximum power loss (1 W) and conversion efficiency (85%). The results of this research are that the proposed HVPS was suitable for driving the micro-channel plate photomultiplier tube (MCP-PMT). It was therefore adopted to test the MCP-PMT, which will be used in Daya Bay reactor neutrino experiment II in China.

  12. CMOS current controlled fully balanced current conveyor

    Science.gov (United States)

    Chunhua, Wang; Qiujing, Zhang; Haiguang, Liu

    2009-07-01

    This paper presents a current controlled fully balanced second-generation current conveyor circuit (CF-BCCII). The proposed circuit has the traits of fully balanced architecture, and its X-Y terminals are current controllable. Based on the CFBCCII, two biquadratic universal filters are also proposed as its applications. The CFBCCII circuits and the two filters were fabricated with chartered 0.35-μm CMOS technology; with ±1.65 V power supply voltage, the total power consumption of the CFBCCII circuit is 3.6 mW. Comparisons between measured and HSpice simulation results are also given.

  13. Magnetoelectric control of spin currents

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, J. E.; Vargas, J. M.; Avilés-Félix, L.; Butera, A. [Centro Atómico Bariloche, Instituto de Nanociencia y Nanotecnología (CNEA) and Conicet, 8400 Bariloche, Río Negro (Argentina)

    2016-06-13

    The ability to control the spin current injection has been explored on a hybrid magnetoelectric system consisting of a (011)-cut ferroelectric lead magnesium niobate-lead titanate (PMNT) single crystal, a ferromagnetic FePt alloy, and a metallic Pt. With this PMNT/FePt/Pt structure we have been able to control the magnetic field position or the microwave excitation frequency at which the spin pumping phenomenon between FePt and Pt occurs. We demonstrate that the magnetoelectric heterostructure operating in the L-T (longitudinal magnetized-transverse polarized) mode couples the PMNT crystal to the magnetostrictive FePt/Pt bilayer, displaying a strong magnetoelectric coefficient of ∼140 Oe cm kV{sup −1}. Our results show that this mechanism can be effectively exploited as a tunable spin current intensity emitter and open the possibility to create an oscillating or a bistable switch to effectively manipulate spin currents.

  14. Magnetoelectric control of spin currents

    International Nuclear Information System (INIS)

    Gómez, J. E.; Vargas, J. M.; Avilés-Félix, L.; Butera, A.

    2016-01-01

    The ability to control the spin current injection has been explored on a hybrid magnetoelectric system consisting of a (011)-cut ferroelectric lead magnesium niobate-lead titanate (PMNT) single crystal, a ferromagnetic FePt alloy, and a metallic Pt. With this PMNT/FePt/Pt structure we have been able to control the magnetic field position or the microwave excitation frequency at which the spin pumping phenomenon between FePt and Pt occurs. We demonstrate that the magnetoelectric heterostructure operating in the L-T (longitudinal magnetized-transverse polarized) mode couples the PMNT crystal to the magnetostrictive FePt/Pt bilayer, displaying a strong magnetoelectric coefficient of ∼140 Oe cm kV −1 . Our results show that this mechanism can be effectively exploited as a tunable spin current intensity emitter and open the possibility to create an oscillating or a bistable switch to effectively manipulate spin currents.

  15. A Current-Fed Isolated Bidirectional DC-DC Converter

    DEFF Research Database (Denmark)

    Sun, Xiaofeng; Wu, Xiaoying; Shen, Yanfeng

    2017-01-01

    This paper proposes a current-fed isolated bidirectional DC-DC converter (CF-IBDC) which has the advantages of wide input voltage range, low input current ripple, low conduction losses, and soft switching over the full operating range. Compared with conventional CF-IBDCs, the voltage spikes...... of the low-voltage (LV) side switches in the proposed converter can be eliminated without additional clamp circuits. The converter adopts the pulse width modulation (PWM) plus hybrid phase-shift control scheme such that the bus voltage can match the output voltage by means of the transformer. Thus......, the current stresses and conduction losses of the converter become lower. In addition, the practical ZVS of the secondary-side switches can be realized by adjusting the phase-shift angle within the secondary side when in light load or no load condition. The operating principles and characteristics including...

  16. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    1993-01-01

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  17. Design of a ZVS PWM inverter for a brushless DC motor in an EMA application

    Science.gov (United States)

    Bell, J. Brett; Nelms, R. M.; Shepherd, Michael T.

    The Component Development Division of the Propulsion Laboratory at Marshall Space Flight Center (MSFC) is currently investigating the use of electromechanical actuators for use in space transportation applications such as Thrust Vector Control (TVC). These high power servomechanisms will require rugged, reliable, and compact power electronic modules capable of modulating several hundred amperes of current at up to 270 Vdc. This paper will discuss the design and implementation of a zero-voltage-switched PWM (Pulse Width Modulation) inverter which operates from a 270 Vdc source at currents up to 100 A.

  18. Current-Processing Current-Controlled Universal Biquad Filter

    Directory of Open Access Journals (Sweden)

    S. V. Singh

    2012-04-01

    Full Text Available This paper presents a current-processing current-controlled universal biquad filter. The proposed filter employs only two current controlled current conveyor transconductance amplifiers (CCCCTAs and two grounded capacitors. The proposed configuration can be used either as a single input three outputs (SITO or as three inputs single output (TISO filter. The circuit realizes all five different standard filter functions i.e. low-pass (LP, band-pass (BP, high-pass (HP, band-reject (BR and all-pass (AP. The circuit enjoys electronic control of quality factor through the single bias current without disturbing pole frequency. Effects of non-idealities are also discussed. The circuit exhibits low active and passive sensitivity figures. The validity of proposed filter is verified through computer simulations using PSPICE.

  19. Stability analysis of direct current control in current source rectifier

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Current source rectifier with high switching frequency has a great potential for improving the power efficiency and power density in ac-dc power conversion. This paper analyzes the stability of direct current control based on the time delay effect. Small signal model including dynamic behaviors...

  20. Current concepts of snail control

    Directory of Open Access Journals (Sweden)

    R. F. Sturrock

    1995-04-01

    Full Text Available Schistosomiasis control was impossible without effective tools. Synthetic molluscicides developed in the 1950s spearheaded community level control. Snail eradication proved impossible but repeated mollusciciding to manage natural snail populations could eliminate transmission. Escalating costs, logistical complexity, its labour-intensive nature and possible environmental effects caused some concern. The arrival of safe, effective, single-dose drugs in the 1970s offered an apparently better alternative but experience revealed the need for repeated treatments to minimise reinfection in programmes relying on drugs alone. Combining treatment with mollusciciding was more successful, but broke down if mollusciciding was withdrawn to save money. The provision of sanitation and safe water to prevent transmission is too expensive in poor rural areas where schistosomiasis is endemic; rendering ineffective public health education linked to primary health care. In the tropics, moreover, children (the key group in maintaining transmission will always play in water. Large scale destruction of natural snail habitats remains impossibly expensive (although proper design could render many new man-made habitats unsuitable for snails. Neither biological control agents nor plant molluscicides have proved satisfactory alternatives to synthetic molluscicides. Biologists can develop effective strategies for using synthetic molluscicides in different epidemiological situations if only, like drugs, their price can be reduced.

  1. Variable current speed controller for eddy current motors

    Science.gov (United States)

    Gerth, H.L.; Bailey, J.M.; Casstevens, J.M.; Dixon, J.H.; Griffith, B.O.; Igou, R.E.

    1982-03-12

    A speed control system for eddy current motors is provided in which the current to the motor from a constant frequency power source is varied by comparing the actual motor speed signal with a setpoint speed signal to control the motor speed according to the selected setpoint speed. A three-phase variable voltage autotransformer is provided for controlling the voltage from a three-phase power supply. A corresponding plurality of current control resistors is provided in series with each phase of the autotransformer output connected to inputs of a three-phase motor. Each resistor is connected in parallel with a set of normally closed contacts of plurality of relays which are operated by control logic. A logic circuit compares the selected speed with the actual motor speed obtained from a digital tachometer monitoring the motor spindle speed and operated the relays to add or substract resistance equally in each phase of the motor input to vary the motor current to control the motor at the selected speed.

  2. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  3. Proportional-Integral-Resonant AC Current Controller

    Directory of Open Access Journals (Sweden)

    STOJIC, D.

    2017-02-01

    Full Text Available In this paper an improved stationary-frame AC current controller based on the proportional-integral-resonant control action (PIR is proposed. Namely, the novel two-parameter PIR controller is applied in the stationary-frame AC current control, accompanied by the corresponding parameter-tuning procedure. In this way, the proportional-resonant (PR controller, common in the stationary-frame AC current control, is extended by the integral (I action in order to enable the AC current DC component tracking, and, also, to enable the DC disturbance compensation, caused by the voltage source inverter (VSI nonidealities and by nonlinear loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, which corresponds to a wide range of AC power converter applications, such as AC motor drives, uninterruptible power supplies, and active filters. While the PIR controllers commonly have three parameters, the novel controller has two. Also, the provided parameter-tuning procedure needs only one parameter to be tuned in relation to the load and power converter model parameters, since the second controller parameter is directly derived from the required controller bandwidth value. The dynamic performance of the proposed controller is verified by means of simulation and experimental runs.

  4. Disturbance observer based current controller for vector controlled IM drives

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Dal, Mehmet

    2008-01-01

    In order to increase the accuracy of the current control loop, usually, well known parameter compensation and/or cross decoupling techniques are employed for advanced ac drives. In this paper, instead of using these techniques an observer-based current controller is proposed for vector controlled...... induction motor (IM) drives. The control design, based on synchronously rotating d-q frame model of the machine, has a simple structure that combines the proportional portion of a conventional PI control and output of the observer. The observer is predicted to estimate the disturbances caused by parameters...... change in current control loop and, also to remove undesired cross coupling existing between components of the stator current. The observer uses the measured stator currents and estimated PWM voltages, and produces a disturbance signal with a low pass filter. The proposed control scheme reduces cross...

  5. Solving transactional control in current management frameworks

    OpenAIRE

    Roque, Vitor; Oliveira, José Luís; Lopes, Rui Pedro

    2004-01-01

    Policy Based Network Management has been presented as a paradigm for efficient and customisable management systems. The IETF has provided a framework to describe the concept but some aspects still open like transactional control. In fact transactional control mechanisms are receiving today great attention in the scope of network management. In here, we identify the lacks of current management paradigms concerning transactional control and we propose a policy-based network manageme...

  6. Solving Transactional Control in Current Management Frameworks

    OpenAIRE

    Roque, Vítor

    2004-01-01

    Policy Based Network Management has been presented as a paradigm for efficient and customisable management systems. The IETF has provided a framework to describe the concept but some aspects still open like transactional control. In fact transactional control mechanisms are receiving today great attention in the scope of network management. In here, we identify the lacks of current management paradigms concerning transactional control and we propose a policy-based network management system th...

  7. Beam current controller for laser ion source

    Science.gov (United States)

    Okamura, Masahiro

    2014-10-28

    The present invention relates to the design and use of an ion source with a rapid beam current controller for experimental and medicinal purposes. More particularly, the present invention relates to the design and use of a laser ion source with a magnetic field applied to confine a plasma flux caused by laser ablation.

  8. A Novel Choice Procedure of Magnetic Component Values for Phase Shifted Full Bridge Converters with a Variable Dead-Time Control Method

    Directory of Open Access Journals (Sweden)

    Lei Zhao

    2015-09-01

    Full Text Available Magnetic components are important parts of the phase shifted full bridge (PSFB converter. During the dead-time of switches located in the same leg, the converter can achieve zero-voltage-switching (ZVS by using the energies stored in magnetic components to discharge or charge the output capacitances of switches. Dead-time is usually calculated under a given set of pre-defined load condition which results in that the available energies are insufficient and ZVS capability is lost at light loads. In this paper, the PSFB converter is controlled by variable dead-time method and thus full advantage can be taken of the energies stored in magnetic components. Considering that dead-time has a great effect on ZVS, the relationship between available energies and magnetic component values is formulated by analyzing the equivalent circuits during dead-time intervals. Magnetic component values are chosen based on such relationship. The proposed choice procedure can make the available energies greater than the required energies for ZVS operation over a wide range of load conditions. Moreover, the burst mode control is adopted in order to reduce the standby power loss. Experimental results coincide with the theoretical analysis. The proposed method is a simple and practical solution to extend the ZVS range.

  9. Current control of light by nonreciprocal magnetoplasmonics

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Yongkang, E-mail: yongkang.gong@southwales.ac.uk; Li, Kang; Carver, Sara; Martinez, Juan Jose; Huang, Jungang; Copner, Nigel [Wireless and Optoelectronics Research and Innovation Centre (WORIC), Faculty of Computing, Engineering and Science, University of South Wales, Cardiff CF37 1DL (United Kingdom); Thueux, Yoann; Avlonitis, Nick [Airbus Group Innovations, Quadrant House, Celtic Springs, Coedkernew, NP10 8FZ Newport (United Kingdom)

    2015-05-11

    The ability to actively control light has long been a major scientific and technological goal. We proposed a scheme that allows for active control of light by utilizing the nonreciprocal magnetoplasmonic effect. As a proof of concept, we applied current signal through an ultrathin metallic film in a magneto-plasmonic multilayer and found that dynamic photonic nonreciprocity appears in magnetic-optical material layer due to the magnetic field being induced from current signal and modulates surface plasmon polaritons trapped in the metal surface and the light reflected. The proposed concept provides a possible way for the active control of light and could find potential applications such as ultrafast optoelectronic signal processing for plasmonic nanocircuit technology and ultrafast/large-aperture free-space electro-optic modulation platform for wireless laser communication technology.

  10. Static current profile control and RFP confinement

    International Nuclear Information System (INIS)

    Scheffel, Jan; Mirza, Ahmed A.; Schnack, Dalton D.

    2013-01-01

    Static current profile control (CPC) is shown numerically to substantially enhance plasma confinement in the reversed-field pinch (RFP). By suitable application of an auxiliary electric field and adjustment of its internal location, width and amplitude, strongly decreased levels of dynamo fluctuations are obtained. The simulations are performed using a fully non-linear, resistive magnetohydrodynamic model, including the effects of ohmic heating as well as parallel and perpendicular heat conduction along stochastic field lines. The importance of controlling the parallel current profile in the core plasma to minimize the effects of tearing modes on confinement is thus confirmed. A near three-fold increase in energy confinement is found and poloidal plasma beta increases by 30% from 0.20 to 0.27. The edge heat flux is reduced to a third of that of the conventional RFP. The high-confinement phase is interrupted here by a crash, characterized by a rapid decrease in confinement. A detailed study of the crash phase is carried out by the standard Δ′ theory and a fully resistive linearized time-spectral method; the generalized weighted residual method. The analysis suggests that the instability is caused by pressure-driven, resistive g-modes. Inclusion of anisotropic thermal conduction reduces the linear growth rates. As compared with our earlier numerical studies of CPC in the RFP, employing feedback control, the present static control scheme should be more easily implemented experimentally. (paper)

  11. Sliding Mode Control of Induction Motor Phase Currents

    DEFF Research Database (Denmark)

    Hansen, R.B.; Hattel, T.; Bork, J

    1995-01-01

    Sliding mode control of induction motor phase currents are investigated through development of two control concepts.......Sliding mode control of induction motor phase currents are investigated through development of two control concepts....

  12. Bioherbicides: Current knowledge on weed control mechanism.

    Science.gov (United States)

    Radhakrishnan, Ramalingam; Alqarawi, Abdulaziz A; Abd Allah, Elsayed Fathi

    2018-04-17

    Weed control is a challenging event during crop cultivation. Integrated management, including the application of bioherbicides, is an emerging method for weed control in sustainable agriculture. Plant extracts, allelochemicals and some microbes are utilized as bioherbicides to control weed populations. Bioherbicides based on plants and microbes inhibit the germination and growth of weeds; however,few studies conducted in weed physiology. This review ascribes the current knowledge of the physiological changes in weeds that occur during the exposure to bioherbicides. Plant extracts or metabolites are absorbed by weed seeds, which initiates damage to the cell membrane, DNA, mitosis, amylase activity and other biochemical processes and delays or inhibits seed germination. The growth of weeds is also retarded due to low rates of root-cell division, nutrient uptake, photosynthetic pigment synthesis, and plant growth hormone synthesis, while the productions of reactive oxygen species (ROS) and stress-mediated hormones increase, including irregular antioxidant activity. However, lytic enzymes and toxic substances secreted from microbes degrade the weed seed coat and utilize the endosperm for survival, which inhibits seed germination. The microbes grow through the intercellular spaces to reach the root core, and the deposition of toxins in the cells affects cell division and cellular functions. Some of the metabolites of deleterious microbes cause disease, necrosis and chlorosis,which inhibit the germination and growth of weed seeds by suppressing photosynthesis and gibberellin activities and enhancing ROS, abscisic acid and ethylene. This review explains the effects of bioherbicides (derived from plants and microbes) on weed-plant physiology to elucidate their modes of action. Copyright © 2018 Elsevier Inc. All rights reserved.

  13. Bus Current Feedback for Motor Control

    National Research Council Canada - National Science Library

    Maase, Hannon

    2000-01-01

    Many algorithms using nonlinear control ideas have been applied to the induction motor control problem to allow the user to control the torque, speed, or position response of a closed loop servo quite precisely...

  14. Current control necessary for toroidal plasma equilibrium

    International Nuclear Information System (INIS)

    Nagao, S.

    1987-01-01

    It is shown that a significant amount of dipole current is necessary for the plasma equilibrium of toroidal configurations in general. Through the vector product with the poloidal field, this dipole current force has to balance with the hoop force of plasma pressure itself of the annular shape. The measurement of such a current of dipole type may be interesting for the confirmation of the plasma equilibrium in the toroidal system. Moreover it is certained that there is a new mode of a tokamak operation with such a dipole current component and with smaller vertical field than that based on the classical tokamak theory. (author) [pt

  15. Thoracic radiotherapy and breath control: current prospects

    International Nuclear Information System (INIS)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R.

    2002-01-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  16. Electrolytic tritium enrichment: Current control using current-stabilised Kepco Type JQE modular supplies

    International Nuclear Information System (INIS)

    1976-01-01

    This note describes the principles, design and operation of a current-stabilised power source for tritium electrolytic enrichment cells. A Kepoo Tpe JE, modular supply is current-stabilised by controlled current feedback. The accompanying control unit incorporates a temperature sensor or the cooling unit of the electrolysis cells, a line monitor to register current shut-off due to temporary power failure, a time-of-day clock, a current control potentiometer and a digital voltmeter providing current reading to an accuracy of 0.01A

  17. Malaria vector control: current and future strategies

    NARCIS (Netherlands)

    Takken, W.; Knols, B.G.J.

    2009-01-01

    The recently announced call for malaria eradication represents a new page in the history of this disease. This has been triggered by remarkable reductions in malaria resulting from combined application of effective drugs and vector control. However, this strategy is threatened by development of

  18. Designing single phase Current-Programmed-Controlled rectifiers by harmonic currents

    DEFF Research Database (Denmark)

    Andersen, Gert Karmisholt; Blaabjerg, Frede

    2002-01-01

    The grid current harmonics of a Current-Programmed-Controlled (CPC) pfc rectifier strongly depends on the choice of switching frequency and switching inductance. This paper describes a new simple and vert fast method to calculate the grid current of a CPC controlled pfc converter. The method...

  19. An Improved Model Predictive Current Controller of Switched Reluctance Machines Using Time-Multiplexed Current Sensor.

    Science.gov (United States)

    Li, Bingchu; Ling, Xiao; Huang, Yixiang; Gong, Liang; Liu, Chengliang

    2017-05-17

    This paper presents a fixed-switching-frequency model predictive current controller using multiplexed current sensor for switched reluctance machine (SRM) drives. The converter was modified to distinguish currents from simultaneously excited phases during the sampling period. The only current sensor installed in the converter was time division multiplexing for phase current sampling. During the commutation stage, the control steps of adjacent phases were shifted so that sampling time was staggered. The maximum and minimum duty ratio of pulse width modulation (PWM) was limited to keep enough sampling time for analog-to-digital (A/D) conversion. Current sensor multiplexing was realized without complex adjustment of either driver circuit nor control algorithms, while it helps to reduce the cost and errors introduced in current sampling due to inconsistency between sensors. The proposed controller is validated by both simulation and experimental results with a 1.5 kW three-phase 12/8 SRM. Satisfied current sampling is received with little difference compared with independent phase current sensors for each phase. The proposed controller tracks the reference current profile as accurately as the model predictive current controller with independent phase current sensors, while having minor tracking errors compared with a hysteresis current controller.

  20. Pain control following inguinal herniorrhaphy: current perspectives

    Science.gov (United States)

    Bjurstrom, Martin F; Nicol, Andrea L; Amid, Parviz K; Chen, David C

    2014-01-01

    Inguinal hernia repair is one of the most common surgeries performed worldwide. With the success of modern hernia repair techniques, recurrence rates have significantly declined, with a lower incidence than the development of chronic postherniorrhaphy inguinal pain (CPIP). The avoidance of CPIP is arguably the most important clinical outcome and has the greatest impact on patient satisfaction, health care utilization, societal cost, and quality of life. The etiology of CPIP is multifactorial, with overlapping neuropathic and nociceptive components contributing to this complex syndrome. Treatment is often challenging, and no definitive treatment algorithm exists. Multidisciplinary management of this complex problem improves outcomes, as treatment must be individualized. Current medical, pharmacologic, interventional, and surgical management strategies are reviewed. PMID:24920934

  1. Oversampled deadbeat current control strategy for PMSM drives

    OpenAIRE

    Rovere, Luca; Formentini, Andrea; Zanchetta, Pericle

    2016-01-01

    This paper presents a novel deadbeat current control approach for Permanent Magnet Synchronous Motors (PMSMs) drives capable of operating at a controller sampling frequency multiple of the power converter switching frequency. The proposed technique permits to achieve a constant switching frequency and an optimal current ripple along with a high current loop bandwidth and robust behaviour to parameter variation.

  2. Pain control following inguinal herniorrhaphy: current perspectives

    Directory of Open Access Journals (Sweden)

    Bjurstrom MF

    2014-05-01

    Full Text Available Martin F Bjurstrom,1,* Andrea L Nicol,2,* Parviz K Amid,3 David C Chen3 1Department of Anesthesiology, UCLA, Los Angeles, CA, USA; 2Department of Anesthesiology, University of Kansas, Kansas City, KS, USA; 3Department of Surgery, Lichtenstein Amid Hernia Clinic at UCLA, UCLA, Los Angeles, CA, USA *These authors contributed equally to this work Abstract: Inguinal hernia repair is one of the most common surgeries performed worldwide. With the success of modern hernia repair techniques, recurrence rates have significantly declined, with a lower incidence than the development of chronic postherniorrhaphy inguinal pain (CPIP. The avoidance of CPIP is arguably the most important clinical outcome and has the greatest impact on patient satisfaction, health care utilization, societal cost, and quality of life. The etiology of CPIP is multifactorial, with overlapping neuropathic and nociceptive components contributing to this complex syndrome. Treatment is often challenging, and no definitive treatment algorithm exists. Multidisciplinary management of this complex problem improves outcomes, as treatment must be individualized. Current medical, pharmacologic, interventional, and surgical management strategies are reviewed. Keywords: inguinodynia, chronic postherniorrhaphy inguinal pain, inguinal hernia

  3. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional...

  4. Current control loop of 3-phase grid-connected inverter

    International Nuclear Information System (INIS)

    Jabbar, A F; Mansor, M

    2013-01-01

    This paper presents a comparative study of current control loop in 3-phase inverter which is used to control the active and reactive output power. Generally, current control loop, power control loop and phase lock-loop are the conventional parameters that can be found in an inverter system controlled by the conventional linear control type, for instance proportional (P), integral (I) and derivative (D). If the grid remains stable throughout the day, PID control can be use. However variation of magnitude, frequency, voltage dips, transient, and other related power quality issues occur in a 3-phase grid often affects the control loop. This paper aims to provide an overall review on the available current control techniques used in grid connected system.

  5. Beam current control system for a high-voltage accelerator

    International Nuclear Information System (INIS)

    Razin, G.I.; Val'tman, D.S.; Timofeev, V.E.

    1979-01-01

    A flowsheet of the beam current control system for commercial accelerators is given. Setting and stabilization of a given beam current value are accomplished by the automatic change of a current of a diode electron gun heater or potential of a qrid of three-electrode gun. Beam current coming to an electron-optical converter generates a control signal supplying electron gun. The system operates in the beam current stabilization regime as well as in the radiation dose stabilization regime. The system response amounts to [ru

  6. Current and Speed Control of the Switched Reluctance Motor

    Directory of Open Access Journals (Sweden)

    Jiri Fort

    2004-01-01

    Full Text Available The papers deals with the problem of the current and speed control of the switched reculttance motor (SRM on the base of the proposed mathematical model of the SRM. The basic types of the controllers are described (proportional controller, PI-controller and controller with the on-line voltage calculation of the mathematical model and the design of their parameters is proposed. Then the comparsion of the simulation and the real drive experimental measurement results is presented.

  7. Adaptive slope compensation for high bandwidth digital current mode controller

    DEFF Research Database (Denmark)

    Taeed, Fazel; Nymand, Morten

    2015-01-01

    An adaptive slope compensation method for digital current mode control of dc-dc converters is proposed in this paper. The compensation slope is used for stabilizing the inner current loop in peak current mode control. In this method, the compensation slope is adapted with the variations...... in converter duty cycle. The adaptive slope compensation provides optimum controller operation in term of bandwidth over wide range of operating points. In this paper operation principle of the controller is discussed. The proposed controller is implemented in an FPGA to control a 100 W buck converter....... The experimental results of measured loop-gain at different operating points are presented to validate the theoretical performance of the controller....

  8. Electrophotographic process control systems utilizing development bias currents

    Science.gov (United States)

    Folkins, Jeffrey J.

    1990-07-01

    Both electrostatic and toner concentration (TC) electrophotographic process control systems can be constructed with the proper use of bias current measurements of the development subsystem. A TC I developability controller can be made by measuring the development bias current for each print or copy, summing the measurements, subtracting offset currents and dispensing toner proportionally to this developed charge measurement. If certain constraints are fulfilled, the system will operate at a constant developed toner mass. Similarly, a photoconductor electrostatic measurement I control system can be made by utilizing bias currents. This is accomplished by choosing a stable portion on the developed charge vs development voltage relationship of the development subsystem. This setpoint is then used to measure photoconductor test patch voltages by monitoring the bias current. In some cases this provides the same function as an electrostatic voltmeter. These low cost techniques enable the practical process control implementations in low and medium speed electrophotographic machines.

  9. Adaptive Current Control Method for Hybrid Active Power Filter

    Science.gov (United States)

    Chau, Minh Thuyen

    2016-09-01

    This paper proposes an adaptive current control method for Hybrid Active Power Filter (HAPF). It consists of a fuzzy-neural controller, identification and prediction model and cost function. The fuzzy-neural controller parameters are adjusted according to the cost function minimum criteria. For this reason, the proposed control method has a capability on-line control clings to variation of the load harmonic currents. Compared to the single fuzzy logic control method, the proposed control method shows the advantages of better dynamic response, compensation error in steady-state is smaller, able to online control is better and harmonics cancelling is more effective. Simulation and experimental results have demonstrated the effectiveness of the proposed control method.

  10. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2003-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as on the actual induction motor, both in open-loop current control and when an outer speed control loop...... as a set of linear matrix inequalities with full-block multipliers. A standard nonlinear model of the motor is constructed and written on LPV form. We then show that, although originally developed in continuous time, the controller synthesis results can be applied to a discrete-time model as well without...

  11. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2003-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... as a set of linear matrix inequalities with full-block multipliers. A standard nonlinear model of the motor is constructed and written on LPV form. We then show that, although originally developed in continuous time, the controller synthesis results can be applied to a discrete-time model as well without...... further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as on the actual induction motor, both in open-loop current control and when an outer speed control loop...

  12. Implementation of the Direct Torque Control (DTC) in current model, with current starting limiter

    OpenAIRE

    Mino Aguilar, Gerardo; Muñoz Hernández, German Ardul; Romeral Martínez, José Luis; Cortez, Liliana; Saynes Torres, J.

    2012-01-01

    This paper presents the scheme of Direct Torque Control (DTC) for induction motor drives, where flux and torque of the motor are estimated by the IM current model. Its scheme requires the knowledge of speed, rotor time constant and inductive parameters of the motor. The results prove the excellent characteristics for torque response and efficiency, which confirm the validity of this control scheme. Due to the rapid response offered by the DTC, this causes a high star current inversor protecti...

  13. Current Decoupling Control Strategy of Medium Voltage Cascaded Multilevel STATCOM

    Directory of Open Access Journals (Sweden)

    Zhao Xuehua

    2014-10-01

    Full Text Available As one of effective regulation methods, static synchronous compensator (STATCOM has been widespread used to regulate dynamic reactive power and solve dynamic voltage stability problems into power-grid. Through the analysis of mathematical model, cascaded STATCOM, which is constructed by several cascaded H-bridges, is a nonlinear, multivariable, strongly coupled system. It will make difficulties in the design and practical application of controller. In this paper, mathematical models of cascaded STATCOM in a -b- c and d-q coordinates are deduced. Based on the theory of internal model control and PI control strategy, the internal decoupling control algorithm is introduced to realize independent control of active current and reactive current. At the same time, decoupling control algorithms are designed and decoupling control models are given and simulated. From the combined circuit topology and control with multi-FPGA, the simulation and experimental platform of cascaded SVG, which use the control algorithms of double-loop control with the current inner loop and capacitor voltage outer loop. Both in a-b-c coordinates and d-q-0 coordinates, experiment and simulation results show that three-phase current of STATCOM has good tracking performance and control precision, which show the regulator design method and parameters setting are feasible and effective.

  14. Model-based current profile control at DIII-D

    International Nuclear Information System (INIS)

    Yongsheng Ou; Schuster, E.; Luce, T.; Ferron, J.; Walker, M.; Humphreys, D.

    2006-01-01

    There is consensus in the fusion community that control of the radial profiles of various plasma quantities (current, pressure, rotation, etc.) will be key to the optimization of burning plasma scenarios. It has been suggested, for instance, that global current profile control, eventually combined with pressure profile control, can be an effective mechanism for neoclassical tearing mode (NTM) control and avoidance. It has been also suggested that simultaneous real-time control of the current and pressure profiles could lead to the steady state sustainment of an internal transport barrier (ITB) and so to a stationary optimized plasma regime. A key goal in control of an advanced tokamak (AT) discharge is to maintain safety factor (q) and pressure profiles that are compatible with both MHD stability at high toroidal beta and a high fraction of the self-generated bootstrap current. This will enable high fusion gain and noninductive sustainment of 100% of the plasma current for steady-state operation. Active feedback control of the q profile evolution at DIII-D has been already demonstrated [J.R. Ferron, et al., '' Control of DIII-D Advanced Tokamak Discharges '', 32 nd EPS Conference on Plasma Physics, Tarragona, 27 June - 1 July 2005, ECA vol. 29C, p. 1,069 (2005)]. In this work we report progress towards enabling model-based active control of the current profile during both plasma current ramp-up and flattop phases. Initial results on modeling and simulation of the dynamic evolution of the poloidal flux profile are presented. Dynamic models will allow the exploitation of recent developments in the field of (nonlinear) control of distributed-parameter systems to solve present profile control problems in magnetic fusion energy. (author)

  15. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2001-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... without further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as experimentally on the actual induction motor, both in open-loop current control and when an outer...... as a set of linear matrix inequalities with full-block multipliers. A standard nonlinear model of the motor is then constructed and written on LPV form. We then show that, although originally developed in continuous time, the controller synthesis results can be applied to a discrete-time model as well...

  16. Current control by a homopolar machine with moving brushes

    International Nuclear Information System (INIS)

    Vogel, H.

    1978-01-01

    The equation for TNS Doublet's E-coil circuit with moving brush homopolar machine is integrated in the flux of the homopolar for a monotonically increasing current function extending beyond the current reversal into the burn period. The results show that the moving brush feature is not useful for controlling the burn

  17. A New Control Method for a Bi-Directional Phase-Shift-Controlled DC-DC Converter with an Extended Load Range

    Directory of Open Access Journals (Sweden)

    Wenzheng Xu

    2017-10-01

    Full Text Available Phase-shifted converters are practically important to provide high conversion efficiencies through soft-switching techniques. However, the limitation on a resonant inductor current in the converters often leads to a non-fulfillment of the requirement of minimum load current. This paper presents a new power electronics control technique to enable the dual features of bi-directional power flow and an extended load range for soft-switching in phase-shift-controlled DC-DC converters. The proposed technique utilizes two identical full bridge converters and inverters in conjunction with a new control logic for gate-driving signals to facilitate both Zero Current Switching (ZCS and Zero Voltage Switching (ZVS in a single phase-shift-controlled DC-DC converter. The additional ZCS is designed for light load conditions at which the minimum load current cannot be attained. The bi-directional phase-shift-controlled DC-DC converter can implement the function of synchronous rectification. Its fast dynamic response allows for quick energy recovery during the regenerative braking of traction systems in electrified trains.

  18. Current Control of Grid Converters Connected with Series AC Capacitor

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    The series ac capacitor has recently been used with the transformerless grid-connected converters in the distribution power grids. The capacitive characteristic of the resulting series LC filter restricts the use of conventional synchronous integral or stationary resonant current controllers. Thus...... this paper proposes a fourth-order resonant controller in the stationary frame, which guarantees a zero steady-state current tracking error for the grid converters with series LC filter. This method is then implemented in a three-phase experimental system for verification, where the current harmonics below...

  19. A PMSM current controller system on FPGA platform | Ahmadian ...

    African Journals Online (AJOL)

    Permanent magnet synchronous motor (PMSM) has gained more interest recently in industrial applications. Digital hardware solutions such as field programmable gate arrays (FPGAs) are the most preferred methods for controlling PMSM drivers. This paper presents an implementation of a current control system for PMSM ...

  20. Asymmetric overlap and hysteresis current control of zero-current switched alternate arm converter

    DEFF Research Database (Denmark)

    Wickramasinghe, Harith R.; Konstantinou, Georgios; Pou, Josep

    2016-01-01

    The alternate arm converter (AAC) is a multilevel converter of the same family as the modular multilevel converter (MMC). Contrary to the MMC, the AAC offers dc-fault tolerant capabilities but requires complex submodule (SM) capacitor voltage/energy regulation and circulating current control. Suc......-spot operation without disturbing the output voltages and currents. The performance and effectiveness of the proposed controller are illustrated through simulations on MATLAB-Simulink and PLECS.......The alternate arm converter (AAC) is a multilevel converter of the same family as the modular multilevel converter (MMC). Contrary to the MMC, the AAC offers dc-fault tolerant capabilities but requires complex submodule (SM) capacitor voltage/energy regulation and circulating current control....... Such control is also limited due to the small overlap period where both arms conduct and energy between the arms can be exchanged. This paper develops a double-band hysteresis-based circulating current control strategy by introducing an asymmetric overlap period control of the director switches (DSs...

  1. Active current control in wind power plants during grid faults

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Phillip C.; Rodriguez, Pedro

    2010-01-01

    Modern wind power plants are required and designed to ride through faults in electrical networks, subject to fault clearing. Wind turbine fault current contribution is required from most countries with a high amount of wind power penetration. In order to comply with such grid code requirements......, wind turbines usually have solutions that enable the turbines to control the generation of reactive power during faults. This paper addresses the importance of using an optimal injection of active current during faults in order to fulfil these grid codes. This is of relevant importance for severe...... faults, causing low voltages at the point of common coupling. As a consequence, a new wind turbine current controller for operation during faults is proposed. It is shown that to achieve the maximum transfer of reactive current at the point of common coupling, a strategy for optimal setting of the active...

  2. Magnetohydrodynamic effects of current profile control in reversed field pinches

    International Nuclear Information System (INIS)

    Sovinec, C.R.; Prager, S.C.

    1999-01-01

    Linear and non-linear MHD computations are used to investigate reversed field pinch configurations with magnetic fluctuations reduced through current profile control. Simulations with reduced ohmic drive and moderate auxiliary current drive, represented generically with an electron force term, applied locally in radius near the plasma edge show magnetic fluctuation energies that are orders of magnitude smaller than those in simulations without profile control. The core of the improved configurations has reduced magnetic shear and closed flux surfaces in some cases, and reversal is sustained through the auxiliary current drive. Modes resonant near the edge may become unstable with auxiliary drive, but their saturation levels can be controlled. The space of auxiliary drive parameters is explored, and the ill effects of deviating far from optimal conditions is demonstrated in non-linear simulations. (author)

  3. Volumetrically controlled ultrafiltration. Current experiences and future prospects.

    Science.gov (United States)

    Roy, T; Ahrenholz, P; Falkenhagen, D; Klinkmann, H

    1982-05-01

    Exact control of ultrafiltration (UF) is a prerequisite for high flux dialysis and hemodiafiltration. Volumetric dialysate balancing is the best current method for the use of dialyzers with high water permeabilities. The precision of UF control by volumetric dialysate balancing is in agreement with all medical requirements. A positive influence of volumetric UF control on patients undergoing chronic hemodialysis can be shown by the frequencies of dialysis side effects. Volumetric UF control is only a first step towards an intelligent UF module to correlate water removal, solute removal and sodium balance.

  4. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  5. Adaptive Current Control with PI-Fuzzy Compound Controller for Shunt Active Power Filter

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    2013-01-01

    Full Text Available An adaptive control technology and PI-fuzzy compound control technology are proposed to control an active power filter (APF. AC side current compensation and DC capacitor voltage tracking control strategy are discussed and analyzed. Model reference adaptive controller for the AC side current compensation is derived and established based on Lyapunov stability theory; proportional and integral (PI fuzzy compound controller is designed for the DC side capacitor voltage control. The adaptive current controller based on PI-fuzzy compound system is compared with the conventional PI controller for active power filter. Simulation results demonstrate the feasibility and satisfactory performance of the proposed control strategies. It is shown that the proposed control method has an excellent dynamic performance such as small current tracking error, reduced total harmonic distortion (THD, and strong robustness in the presence of parameters variation and nonlinear load.

  6. On Ion Cyclotron Current Drive for sawtooth control

    International Nuclear Information System (INIS)

    Eriksson, L.-G.; Johnson, T.; Hellsten, T.; Mayoral, M.-L.; McDonald, D.; Santala, M.; Vries, P. de; Coda, S.; Sauter, O.; Mueck, A.; Buttery, R.J.; Mantsinen, M.J.; Noterdaeme, J.-M.; Westerhof, E.

    2006-01-01

    Experiments using Ion Cyclotron Current Drive (ICCD) to control sawteeth are presented. In particular, discharges demonstrating shortening of fast ion induced long sawteeth reported in [L.-G. Eriksson et al., Physical Review Letters 92, 235004 (2004)] by ICCD have been analysed in detail. Numerical simulations of the ICCD driven currents are shown to be consistent with the experimental observations. They support the hypothesis that an increase of the magnetic shear, due to the driven current, at the surface where the safety factor is unity was the critical factor for the shortening of the sawteeth. In view of the potential utility of ICCD, the mechanisms for the current drive have been further investigated experimentally. This includes the influence of the averaged energy of the resonating ions carrying the current and the spectrum of the launched waves. The results of these experiments are discussed in the light of theoretical considerations. (author)

  7. Current control for magnetized plasma in direct-current plasma-immersion ion implantation

    International Nuclear Information System (INIS)

    Tang Deli; Chu, Paul K.

    2003-01-01

    A method to control the ion current in direct-current plasma-immersion ion implantation (PIII) is reported for low-pressure magnetized inductively coupled plasma. The ion current can be conveniently adjusted by applying bias voltage to the conducting grid that separates plasma formation and implantation (ion acceleration) zones without the need to alter the rf input power, gas flux, or other operating conditions. The ion current that diminishes with an increase in grid bias in magnetized plasmas can be varied from 48 to 1 mA by increasing the grid voltage from 0 to 70 V at -50 kV sample bias and 0.5 mTorr hydrogen pressure. High implantation voltage and monoenergetic immersion implantation can now be achieved by controlling the ion current without varying the macroscopic plasma parameters. The experimental results and interpretation of the effects are presented in this letter. This technique is very attractive for PIII of planar samples that require on-the-fly adjustment of the implantation current at high implantation voltage but low substrate temperature. In some applications such as hydrogen PIII-ion cut, it may obviate the need for complicated sample cooling devices that must work at high voltage

  8. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  9. Stator Current Harmonic Control with Resonant Controller for Doubly Fed Induction Generator

    DEFF Research Database (Denmark)

    Liu, Changjin; Blaabjerg, Frede; Chen, Wenjie

    2012-01-01

    Voltage harmonics in the grid can introduce stator current harmonics in a doubly fed induction generator (DFIG) wind turbine system, which may potentially impact the generated power quality. Therefore, wind turbine current controllers need to be designed to eliminate the impact of grid voltage...... harmonics, especially low-order harmonics. This paper proposes a stator current harmonic suppression method using a sixth-order resonant controller to eliminate negative sequence fifth- and positive sequence seventh-order current harmonics. A stator current harmonic control loop is added to the conventional...... rotor current control loop for harmonic suppression. The overall control scheme is implemented in dq frame. Based on a mathematical model of the DFIG control system, the effects on system stability using the resonant controller, an analysis of the steady-state error, and the dynamic performance...

  10. Real-time control for long ohmic alternate current discharges

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Hekkert, Tiago; Carvalho, Bernardo B.; Gomes, Rui B.

    2014-05-15

    Highlights: • 40 Alternate plasma current (AC) semi-cycles without loss of ionization, more than 1 s of operation. • AC discharges automatic control: feedback loops, time-windows control strategy, goal oriented time-windows and exception handling. • Energy deposition and Carbon radiation evolution during the AC discharges. - Abstract: The ISTTOK tokamak has a long tradition on alternate plasma current (AC) discharges, but the old control system was limiting and lacked full system integration. In order to improve the AC discharges performance the ISTTOK fast control system was updated. This control system developed on site based on the Advanced Telecommunications Computing Architecture (ATCA) standard now integrates the information gathered by all the tokamak real-time diagnostics to produce an accurate observation of the plasma parameters. The real-time actuators were also integrated, allowing a Multiple Input Multiple Output (MIMO) control environment with several synchronization strategies available. The control system software was developed in C++ on top of a Linux system with the Multi-threaded Application Real-Time executor (MARTe) Framework to synchronize the real-time code execution under a 100μs control cycle. In addition, to simplify the discharge programming, a visual Human–Machine Interface (HMI) was also developed using the BaseLib2 libraries included in the MARTe Framework. This paper presents the ISTTOK control system and the optimizations that extended the AC current discharges duration to more than 1 s, corresponding to 40 semi-cycles without apparent degradation of the plasma parameters. This upgrade allows ISTTOK to be used as a low-cost material testing facility with long time exposures to nuclear fusion relevant plasmas, comparable (in duration) with medium size tokamaks.

  11. Central Neural Control of the Cardiovascular System: Current Perspectives

    Science.gov (United States)

    Dampney, Roger A. L.

    2016-01-01

    This brief review, which is based on a lecture presented at the American Physiological Society Teaching Refresher Course on the Brain and Systems Control as part of the Experimental Biology meeting in 2015, aims to summarize current concepts of the principal mechanisms in the brain that regulate the autonomic outflow to the cardiovascular system.…

  12. High performance current controller for particle accelerator magnets supply

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Bidoggia, Benoit; Munk-Nielsen, Stig

    2013-01-01

    The electromagnets in modern particle accelerators require high performance power supply whose output is required to track the current reference with a very high accuracy (down to 50 ppm). This demands very high bandwidth controller design. A converter based on buck converter topology is used...

  13. Concepts Concerning 'Disease\\' Causation, Control, and the current ...

    African Journals Online (AJOL)

    There is an ethical necessity that doctors understand the complex social, political, environmental and economic dynamics involved in infectious disease outbreaks. This article discusses some important concepts concerning 'disease' causation and control with specific reference to the current cholera outbreak in Zimbabwe ...

  14. Spin-torque switching and control using chirped AC currents

    Science.gov (United States)

    Klughertz, Guillaume; Friedland, Lazar; Hervieux, Paul-Antoine; Manfredi, Giovanni

    2017-10-01

    We propose to use oscillating spin currents with slowly varying frequency (chirp) to manipulate and control the magnetization dynamics in a nanomagnet. By recasting the Landau-Lifshitz-Slonczewski equation in a quantum-like two-level formalism, we show that a chirped spin current polarized in the direction normal to the anisotropy axis can induce a stable precession of the magnetic moment at any angle (up to 90^\\circ ) with respect to the anisotropy axis. The drive current can be modest (10^6~A~cm-2 or lower) provided the chirp rate is sufficiently slow. The induced precession is stable against thermal noise, even for small nano-objects at room temperature. Complete reversal of the magnetization can be achieved by adding a small external magnetic field antiparallel to the easy axis. Alternatively, a combination of chirped ac and dc currents with different polarization directions can also be used to trigger the reversal.

  15. Advanced induction motor drive control with single current sensor

    Directory of Open Access Journals (Sweden)

    Adžić Evgenije M.

    2016-01-01

    Full Text Available This paper proposes induction motor drive control method which uses minimal number of sensors, providing only DC-link current as a feedback signal. Improved DC-link current sampling scheme and modified asymmetrical switching pattern cancels characteristic waveform errors which exist in all three reconstructed motor line-currents. Motor linecurrent harmonic content is reduced to an acceptable level, eliminating torque and speed oscillations which were inherent for conventional single sensor drives. Consequently, use of single current sensor and line-current reconstruction technique is no longer acceptable only for low and medium performance drives, but also for drives where priority is obtaining a highly accurate, stable and fast response. Proposed control algorithm is validated using induction motor drive hardware prototype based on TMS320F2812 digital signal processor. [Projekat Ministarstva nauke Republike Srbije, br. III 042004 and by the Provincial Secretariat for Science and Technological Development of AP Vojvodina under contract No. 114-451-3508/2013-04

  16. Control of optically induced currents in semiconductor crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, Kapil Kumar

    2010-06-01

    The generation and control of optically induced currents has the potential to become an important building block for optical computers. Here, shift and rectification currents are investigated that emerge from a divergence of the optical susceptibility. It is known that these currents react to the shape of the impinging laser pulse, and especially to the shape of the pulse envelope. The main goal is the systematic manipulation of the pulse envelope with an optical pulse shaper that is integrated into a standard THz emission setup. The initial approach, the chirping of the laser pulse only has a weak influence on the envelope and the currents. Instead, a second approach is suggested that uses the combined envelope of a phase-stable pulse-pair as a parameter. In a laser pulse, the position of the maxima of the electrical field and the pulse envelope are shifted relative to each other. This shift is known as the Carrier-Envelope Phase (CEP). It is a new degree of freedom that is usually only accessible in specially stabilized systems. It is shown, that in a phase-stable pulse-pair, at least the relative CEP is usable as a new degree of freedom. It has a great influence on the shape of the pulse envelope and thus on the current density. It is shown that this approach enables the coherent control of the current density. The experiments are corroborated by a theoretical model of the system. The potential of this approach is demonstrated in an application. A framework is presented that uses an iterative genetic algorithm to create arbitrarily shaped THz traces. The algorithm controls the optical pulse shaper, and varies the phase of the impinging laser pulses until the desired target trace is found. (orig.)

  17. HOM frequency control of SRF cavity in high current ERLs

    Science.gov (United States)

    Xu, Chen; Ben-Zvi, Ilan

    2018-03-01

    The acceleration of high-current beam in Superconducting Radio Frequency (SRF) cavities is a challenging but essential for a variety of advanced accelerators. SRF cavities should be carefully designed to minimize the High Order Modes (HOM) power generated in the cavities by the beam current. The reduction of HOM power we demonstrate in a particular case can be quite large. This paper presents a method to systematically control the HOM resonance frequencies in the initial design phase to minimize the HOM power generation. This method is expected to be beneficial for the design of high SRF cavities addressing a variety of Energy Recovery Linac (ERL) applications.

  18. Cancer pain and current theory for pain control.

    Science.gov (United States)

    Kahan, Brian

    2014-05-01

    This article discusses current trends in managing cancer pain, with specific regard to opioid transmission, descending pathway inhabitation, and ways to facilitate the endogenous antinociceptive chemicals in the human body. Various techniques for opioid and nonopioid control of potential pain situations of patients with cancer are discussed. The benefits of using pharmacogenetics to assess the appropriate medications are addressed. Finally, specific treatment of abdominal cancer pain using radiofrequency lesioning is discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  19. Shear optimization experiments with current profile control on JET

    International Nuclear Information System (INIS)

    1997-01-01

    A record performance on JET has been obtained with shear optimization scenarios. A neutron yield of 5.6x10 16 s -1 in deuterium discharges, and a global energy confinement improvement above the ITER-89 L-mode scaling with H ≤ 2.5 in L-mode and H ≤ 3 in H-mode have been achieved. The tailoring of plasma current, density and heating power waveforms and current profile control with lower hybrid current drive and ICRF phasing have been essential. Internal energy, particle and momentum transport barriers develop spontaneously upon heating above a threshold power of about 15 MW with neutral beams and ICRH into a low-density target plasma, with a wide central region of slightly negative or flat magnetic shear with q > 1 everywhere. An additional H-mode transition can also raise the pressure in the region between internal and edge transport barriers. The ion heat conductivity falls to the neoclassical level in the improved core confinement region. Pressure profile control through power deposition feedback control makes it possible to work close to the marginal stability boundary for pressure-driven MHD modes. First experiments in deuterium/tritium plasmas, with up to 75% tritium target concentration, have established internal transport barriers already with heating powers at the lowest threshold of pure deuterium plasmas, resulting in a fusion power output of P fusion = 2 MW. (author)

  20. Tuberculosis control in prisons: current situation and research gaps.

    Science.gov (United States)

    Dara, Masoud; Acosta, Colleen D; Melchers, Natalie V S Vinkeles; Al-Darraji, Haider A A; Chorgoliani, Dato; Reyes, Hernan; Centis, Rosella; Sotgiu, Giovanni; D'Ambrosio, Lia; Chadha, Sarabjit S; Migliori, Giovanni Battista

    2015-03-01

    Tuberculosis (TB) in penitentiary services (prisons) is a major challenge to TB control. This review article describes the challenges that prison systems encounter in TB control and provides solutions for the more efficient use of limited resources based on the three pillars of the post-2015 End TB Strategy. This paper also proposes research priorities for TB control in prisons based on current challenges. Articles (published up to 2011) included in a recent systematic review on TB control in prisons were further reviewed. In addition, relevant articles in English (published 1990 to May 2014) were identified by searching keywords in PubMed and Google Scholar. Article bibliographies and conference abstracts were also hand-searched. Despite being a serious cause of morbidity and mortality among incarcerated populations, many prison systems encounter a variety of challenges that hinder TB control. These include, but are not limited to, insufficient laboratory capacity and diagnostic tools, interrupted supply of medicines, weak integration between civilian and prison TB services, inadequate infection control measures, and low policy priority for prison healthcare. Governmental commitment, partnerships, and sustained financing are needed in order to facilitate improvements in TB control in prisons, which will translate to the wider community. Copyright © 2015 World Health Organization. Published by Elsevier Ltd.. All rights reserved.

  1. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    Science.gov (United States)

    Leng, Min-Rui; Zhou, Guo-Hua; Zhang, Kai-Tun; Li, Zhen-Hua

    2015-10-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. Project supported by the National Natural Science Foundation of China (Grant No. 61371033), the Fok Ying-Tung Education Foundation for Young Teachers in the Higher Education Institutions of China (Grant No. 142027), the Sichuan Provincial Youth Science and Technology Fund, China (Grant Nos. 2014JQ0015 and 2013JQ0033), and the Fundamental Research Funds for the Central Universities, China (Grant No. SWJTU11CX029).

  2. Improved control strategy for PI-R current of DFIG considering voltage and current harmonics compensation

    Science.gov (United States)

    Song, S. Y.; Liu, Q. H.; Zhao, Y. N.; Liu, S. Y.

    2016-08-01

    With the rapid development of wind power generation, the related research of wind power control and integration issues has attracted much attention, and the focus of the research are shifting away from the ideal power grid environment to the actual power grid environment. As the main stream wind turbine generator, a doubly-fed induction generator (DFIG) is connected to the power grid directly by its stator, so it is particularly sensitive to the power grid. This paper studies the improvement of DFIG control technology in the power grid harmonic environment. Based on the DFIG dynamic model considering the power grid harmonic environment, this paper introduces the shortcomings of the common control strategy of DFIG, and puts forward the enhanced method. The decoupling control of the system is realized by compensating the coupling between the rotor harmonic voltage and harmonic current, improving the control performance. In addition, the simulation experiments on PSCAD/EMTDC are carried out to verify the correctness and effectiveness of the improved scheme.

  3. Prevention and control of schistosomiasis: a current perspective

    Directory of Open Access Journals (Sweden)

    Inobaya MT

    2014-10-01

    Full Text Available Marianette T Inobaya,1 Remigio M Olveda,1 Thao NP Chau,3 David U Olveda,2 Allen GP Ross21Department of Health, Research Institute for Tropical Medicine, Muntinlupa City, Philippines; 2Griffith Health Institute, School of Medical Sciences, Gold Coast Campus, Griffith University, Southport, Australia; 3Discipline of Public Health, Flinders University, Adelaide, AustraliaAbstract: Schistosomiasis is a neglected tropical disease that ranks second only to malaria in terms of human suffering in the tropics and subtropics. Five species are known to infect man and there are currently over 240 million people infected worldwide. The cornerstone of control to date has been mass drug administration with 40 mg/kg of praziquantel but there are problems with this approach. Human and bovine vaccines are in various stages of development. Integrated control, targeting the life cycle, is the only approach that will lead to sustainability and future elimination.Keywords: schistosomiais, morbidity, treatment and control, mass drug administration

  4. Current Approaches for Control Room I and C Modernization

    International Nuclear Information System (INIS)

    Lopez, Alberto; Jimenez, Alfonso

    2002-01-01

    In general, instrumentation and control (I and C) systems for nuclear power plants were made using analogic systems and relays, since this was the only technology available by the time these systems were designed. This fact impacts on the operational and maintenance capabilities required to these systems. For this reason, nuclear power plants are facing nowadays two challenges: on one hand, the obsolescence of these systems contributes to the increase in the operation and maintenance costs - due to the difficulties for getting spare parts and support from the system vendors -. On the other hand, there has been an increase in the utilities competitiveness due to the electric power market liberalization. All this, of course, along with the commitment to maintain the current safety levels and meet the new requirements and standards that may arise in the near future. The application of current technologies, especially digital technology, solves the obsolescence problems and allows for a more functional and updated human-machine interface. Nevertheless, the cost associated to these modifications makes it necessary to develop strategies to determine which systems need to be modified and how to implement modifications effectively, so that these systems can work jointly with others using different technologies. Other issues inherent to digital technology must be considered, such as verification and validation of the software and of the human-machine interface, which are required for its licensing. This presentation describes the current approaches for I and C modernization, the main reasons, technologies and implementation plans, focusing on the control room and on the impact on operations. The main issues to be considered for developing a specific modernization plan are analysed. The goals and status of the 'Feasibility Study of the Control Room I and C Modernization' are described. This study is currently being developed by Endesa, Iberdrola and Tecnatom, and is included

  5. Precision electronic speed controller for an alternating-current motor

    Science.gov (United States)

    Bolie, V.W.

    A high precision controller for an alternating-current multi-phase electrical motor that is subject to a large inertial load. The controller was developed for controlling, in a neutron chopper system, a heavy spinning rotor that must be rotated in phase-locked synchronism with a reference pulse train that is representative of an ac power supply signal having a meandering line frequency. The controller includes a shaft revolution sensor which provides a feedback pulse train representative of the actual speed of the motor. An internal digital timing signal generator provides a reference signal which is compared with the feedback signal in a computing unit to provide a motor control signal. The motor control signal is a weighted linear sum of a speed error voltage, a phase error voltage, and a drift error voltage, each of which is computed anew with each revolution of the motor shaft. The speed error signal is generated by a novel vernier-logic circuit which is drift-free and highly sensitive to small speed changes. The phase error is also computed by digital logic, with adjustable sensitivity around a 0 mid-scale value. The drift error signal, generated by long-term counting of the phase error, is used to compensate for any slow changes in the average friction drag on the motor. An auxillary drift-byte status sensor prevents any disruptive overflow or underflow of the drift-error counter. An adjustable clocked-delay unit is inserted between the controller and the source of the reference pulse train to permit phase alignment of the rotor to any desired offset angle. The stator windings of the motor are driven by two amplifiers which are provided with input signals having the proper quadrature relationship by an exciter unit consisting of a voltage controlled oscillator, a binary counter, a pair of read-only memories, and a pair of digital-to-analog converters.

  6. Current vector control challenges in the fight against malaria.

    Science.gov (United States)

    Benelli, Giovanni; Beier, John C

    2017-10-01

    The effective and eco-friendly control of Anopheles vectors plays a key role in any malaria management program. Integrated Vector Management (IVM) suggests making use of the full range of vector control tools available. The strategies for IVM require novel technologies to control outdoor transmission of malaria. Despite the wide number of promising control tools tested against mosquitoes, current strategies for malaria vector control used in most African countries are not sufficient to achieve successful malaria control. The majority of National Malaria Control Programs in Africa still rely on indoor residual spraying (IRS) and long-lasting insecticidal nets (LLINs). These methods reduce malaria incidence but generally have little impact on malaria prevalence. In addition to outdoor transmission, growing levels of insecticide resistance in targeted vectors threaten the efficacy of LLINs and IRS. Larvicidal treatments can be useful, but are not recommended for rural areas. The research needed to improve the quality and delivery of mosquito vector control should focus on (i) optimization of processes and methods for vector control delivery; (ii) monitoring of vector populations and biting activity with reliable techniques; (iii) the development of effective and eco-friendly tools to reduce the burden or locally eliminate malaria and other mosquito-borne diseases; (iv) the careful evaluation of field suitability and efficacy of new mosquito control tools to prove their epidemiological impact; (v) the continuous monitoring of environmental changes which potentially affect malaria vector populations; (vi) the cooperation among different disciplines, with main emphasis on parasitology, tropical medicine, ecology, entomology, and ecotoxicology. A better understanding of behavioral ecology of malaria vectors is required. Key ecological obstacles that limit the effectiveness of vector control include the variation in mosquito behavior, development of insecticide resistance

  7. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  8. High-Speed Current dq PI Controller for Vector Controlled PMSM Drive

    Science.gov (United States)

    Reaz, Mamun Bin Ibne; Rahman, Labonnah Farzana; Chang, Tae Gyu

    2014-01-01

    High-speed current controller for vector controlled permanent magnet synchronous motor (PMSM) is presented. The controller is developed based on modular design for faster calculation and uses fixed-point proportional-integral (PI) method for improved accuracy. Current dq controller is usually implemented in digital signal processor (DSP) based computer. However, DSP based solutions are reaching their physical limits, which are few microseconds. Besides, digital solutions suffer from high implementation cost. In this research, the overall controller is realizing in field programmable gate array (FPGA). FPGA implementation of the overall controlling algorithm will certainly trim down the execution time significantly to guarantee the steadiness of the motor. Agilent 16821A Logic Analyzer is employed to validate the result of the implemented design in FPGA. Experimental results indicate that the proposed current dq PI controller needs only 50 ns of execution time in 40 MHz clock, which is the lowest computational cycle for the era. PMID:24574913

  9. Research on automatic current sharing control methods for control power supply

    Directory of Open Access Journals (Sweden)

    Dai Xian Bin

    2016-01-01

    Full Text Available High-power switching devices in control power supply have different saturated forward voltage drops and the inconsistency of turning on/off times and they lead to the inconsistency in the external characteristics of the inverter modules in parallel operation. Modules with good performance in external characteristics undertake more currents and lead to overloading status and modules with bad performance in external characteristics stay in light-loading status, which increases the thermal stress of module undertaking more currents and influences the service life of high-power switching devices. Based on the simulation analysis of the small-signal module using control power supply automatic current sharing method, it is able to find out the characteristics of current-sharing loop control, namely, slow response speed of the current-sharing loop, which is beneficial for improving the stability of the entire control power supply system.

  10. Current status and strategies for viral hepatitis control in Korea

    Directory of Open Access Journals (Sweden)

    Dong Hyun Sinn

    2017-09-01

    Full Text Available Viral hepatitis is one of major global health challenges with increasing disease burden worldwide. Hepatitis B virus and hepatitis C virus infections are major causes of chronic liver diseases. They can lead to cirrhosis, hepatocellular carcinoma, and death in significant portion of affected people. Transmission of hepatitis B virus can be blocked by vaccination. Progression of hepatitis B virus-related liver diseases can be prevented by long-term viral suppression with effective drugs. Although vaccine for hepatitis C virus is currently unavailable, hepatitis C virus infection can be eradicated by oral direct antiviral agents. To eliminate viral hepatitis, World Health Organization (WHO has urged countries to develop national goals and targets through reducing 90% of new infections and providing universal access to key treatment services up to 80%. This can lead to 65% reduction of viral hepatitis-related mortality. Here, we discuss some key features of viral hepatitis, strategies to control viral hepatitis suggested by WHO, and current status and strategies for viral hepatitis control in South Korea. To achieve the goal of viral hepatitis elimination by 2030 in South Korea, an independent 'viral hepatitis sector' in Centers for Disease Control & Prevention (CDC needs to be established to organize and execute comprehensive strategy for the management of viral hepatitis in South Korea.

  11. A Harmonic Current Suppression Control Strategy for Droop-Controlled Inverter Connected to the Distorted Grid

    DEFF Research Database (Denmark)

    Wei, Feng; Sun, Kai; Guan, Yajuan

    2015-01-01

    The grid-feeding voltage controlled inverter (GF-VCI) based on droop control is vulnerable to the harmonic voltages of the utility grid. Because of the equivalent impedance of system is small, the slight distorted grid voltage will result in the harmonic component increasing of GF-VCI output...... currents. Therefore, the reason of generation of distorted grid-feeding current of GF-VCI under the distorted grid voltage is investigated firstly in this paper. Then, a harmonic grid-feeding current suppression control strategy for GF-VCI is proposed. Two different filters are compared and analysed before...... being adopted for abstracting the fundamental components of grid voltage. The injected fundamental power is controlled through droop controller, and a hybrid voltage controller of GF-VCI with PI and R regulators in rotary frame is adopted for improving of the tracking capability of the grid harmonic...

  12. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  13. Predictive current control of permanent magnet synchronous motor based on linear active disturbance rejection control

    Science.gov (United States)

    Li, Kunpeng

    2017-01-01

    The compatibility problem between rapidity and overshooting in the traditional predictive current control structure is inevitable and difficult to solve by reason of using PI controller. A novel predictive current control (PCC) algorithm for permanent magnet synchronous motor (PMSM) based on linear active disturbance rejection control (LADRC) is presented in this paper. In order to displace PI controller, the LADRC strategy which consisted of linear state error feedback (LSEF) control algorithm and linear extended state observer (LESO), is designed based on the mathematic model of PMSM. The purpose of LSEF is to make sure fast response to load mutation and system uncertainties, and LESO is designed to estimate the uncertain disturbances. The principal structures of the proposed system are speed outer loop based on LADRC and current inner loop based on predictive current control. Especially, the instruction value of qaxis current in inner loop is derived from the control quantity which is designed in speed outer loop. The simulation is carried out in Matlab/Simulink software, and the results illustrate that the dynamic and static performances of proposed system are satisfied. Moreover the robust against model parameters mismatch is enhanced obviously.

  14. Seizing Control: From Current Treatments to Optogenetic Interventions in Epilepsy.

    Science.gov (United States)

    Bui, Anh D; Alexander, Allyson; Soltesz, Ivan

    2015-12-23

    The unpredictability and severity of seizures contribute to the debilitating nature of epilepsy. These factors also render the condition particularly challenging to treat, as an ideal treatment would need to detect and halt the pathological bursts of hyperactivity without disrupting normal brain activity. Optogenetic techniques offer promising tools to study and perhaps eventually treat this episodic disorder by controlling specific brain circuits in epileptic animals with great temporal precision. Here, we briefly review the current treatment options for patients with epilepsy. We then describe the many ways optogenetics has allowed us to untangle the microcircuits involved in seizure activity, and how it has, in some cases, changed our perception of previous theories of seizure generation. Control of seizures with light is no longer a dream, and has been achieved in numerous different animal models of epilepsy. Beyond its application as a seizure suppressor, we highlight another facet of optogenetics in epilepsy, namely the ability to create "on-demand" seizures, as a tool to systematically probe the dynamics of networks during seizure initiation and propagation. Finally, we look into the future to discuss the possibilities and challenges of translating optogenetic techniques to clinical use. © The Author(s) 2015.

  15. Current trends in small vocabulary speech recognition for equipment control

    Science.gov (United States)

    Doukas, Nikolaos; Bardis, Nikolaos G.

    2017-09-01

    Speech recognition systems allow human - machine communication to acquire an intuitive nature that approaches the simplicity of inter - human communication. Small vocabulary speech recognition is a subset of the overall speech recognition problem, where only a small number of words need to be recognized. Speaker independent small vocabulary recognition can find significant applications in field equipment used by military personnel. Such equipment may typically be controlled by a small number of commands that need to be given quickly and accurately, under conditions where delicate manual operations are difficult to achieve. This type of application could hence significantly benefit by the use of robust voice operated control components, as they would facilitate the interaction with their users and render it much more reliable in times of crisis. This paper presents current challenges involved in attaining efficient and robust small vocabulary speech recognition. These challenges concern feature selection, classification techniques, speaker diversity and noise effects. A state machine approach is presented that facilitates the voice guidance of different equipment in a variety of situations.

  16. Control systems for ITER diagnostics, heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Simrock, Stefan, E-mail: stefan.simrock@iter.org

    2016-11-15

    The ITER Diagnostic, Heating and Current Drive systems might appear, on the face of it, to have very different control requirements. There are approximately 45 diagnostic systems, including magnetic sensors for plasma position and shape determination, imaging systems in the IR and visible, Thompson scattering for electron temperature and density, neutron detectors and collective scattering for alpha particle density and energy distribution. The H&CD systems encompass Electron Cyclotron Heating, using 24 1MW, 170 GHz gyrotrons and 5 steerable launchers to deliver 20 MW to the plasma, Ion Cyclotron Heating, using 8 3MW, 40–55 MHz sources and two multi-element launchers to deliver 20 MW to the plasma, and 2 Negative Ion Neutral Beam Injectors, each of which can deliver up to 16.5 MW of 1 MeV beams to the plasma. Although there are substantial differences in the needs for protection, when handling multi-MW heating systems, and in data throughput for many diagnostics, the formal processes needed to translate system requirements into Instrumentation and Control are identical. Due to the distributed procurement of ITER sub-systems and the need to integrate as painlessly as possible to CODAC, the formal processes, together with a substantial degree of standardization, are even more than usually essential. Starting from the technical, safety and protection, integration and operation requirements, a loop of functional analysis and signal listing is used to generate the controller configuration and the conceptual architecture. These elements in their turn lead to the physical and software design. The paper will describe the formal processes of control system design and the methods used by the ITER project to achieve the standardization of systems engineering practices. These have been applied to several use-cases covering all operation relevant phases such as plasma operation, maintenance, testing and conditioning. There are a number of running contracts that are developing

  17. Balanced Current Control Strategy for Current Source Rectifier Stage of Indirect Matrix Converter under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yeongsu Bak

    2016-12-01

    Full Text Available This paper proposes a balanced current control strategy for the current source rectifier (CSR stage of an indirect matrix converter (IMC under unbalanced grid voltage conditions. If the three-phase grid connected to the voltage source inverter (VSI of the IMC has unbalanced voltage conditions, it affects the currents of the CSR stage and VSI stage, and the currents are distorted. Above all, the distorted currents of the CSR stage cause instability in the overall system, which can affect the life span of the system. Therefore, in this paper, a control strategy for balanced currents in the CSR stage is proposed. To achieve balanced currents in the CSR stage, the VSI stage should receive DC power without ripple components from the CSR stage. This is implemented by controlling the currents in the VSI stage. Therefore, the proposed control strategy decouples the positive and negative phase-sequence components existing in the unbalanced voltages and currents of the VSI stage. Using the proposed control strategy under unbalanced grid voltage conditions, the stability and life span of the overall system can be improved. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

  18. Current profile control experiments in EXTRAP T2R

    Science.gov (United States)

    Brunsell, P.; Cecconello, M.; Drake, J.; Franz, P.; Malmberg, J. A.; Marrelli, L.; Martin, P.; Spizzo, G.

    2002-11-01

    EXTRAP T2R is a high aspect ratio (R=1.24 m, a = 0.183 m) reversed-field pinch device, characterised by a double, thin shell system. The simultaneous presence of many m=1, |n| > 11 tearing modes is responsible for a magnetic field turbulence, which is believed to produce the rather high energy and particle transport that is observed in this type of magnetic configuration. In this paper first results from current profile control experiments (PPCD) in a thin shell device are shown. When an edge poloidal electric field is transiently applied, an increase of the electron temperature and of the electron density is seen, which is consistent with an increase of the thermal content of the plasma. At the same time, the soft x-ray emission, measured with a newly installed miniaturised camera, shows a peaking of the profile in the core. Furthermore, the amplitudes of the m=1 tearing modes are reduced and and the rotation velocities increase during PPCD, which is also consistent with a reduction of magnetic turbulence and a heating of the plasma

  19. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...... cause noise amplification. In light of the above issue, this paper develops a simple method for the ICF control system to mitigate the grid current harmonics without extra sensors. In the proposed method, resonant harmonic controllers and an additional compensation loop are adopted at the same time...

  20. IPMSM velocity and current control using MTPA based adaptive fractional order sliding mode controller

    Directory of Open Access Journals (Sweden)

    Sayed Hamed Hosseini

    2017-06-01

    Full Text Available This paper presents a two-loop approach for velocity and stator currents control of an Interior-type Permanent Magnet Synchronous Motor (IPMSM. In the outer loop, the reference torque obtained from a conventional PI controller gives two-axis stator reference currents based on Maximum-Torque per Ampere (MTPA strategy. In the inner loop, an adaptive fractional order sliding mode controller is designed to reach the two-axis stator currents to their reference values obtained from the MTPA method. To achieve this idea, fractional order sliding surfaces and an adaptive controller with adjustable parameters are employed. The adaptive controller is designed to increase the robustness of the proposed method against the uncertainties in stator resistance and inductances. A Lyapunov based adaptation mechanism is proposed for adjustment of the controller parameters. The optimal value of the fractional orders are obtained by optimization of an integral time absolute error performance index. The simulation results show the robustness of the proposed method against the uncertainties in stator resistance and stator inductances.

  1. Steam generator degradation: Current mitigation strategies for controlling corrosion

    International Nuclear Information System (INIS)

    Millett, P.

    1997-01-01

    Steam Generator degradation has caused substantial losses of power generation, resulted in large repair and maintenance costs, and contributed to significant personnel radiation exposures in Pressurized Water Reactors (PWRs) operating throughout the world. EPRI has just published the revised Steam Generator Reference Book, which reviews all of the major forms of SG degradation. This paper discusses the types of SG degradation that have been experienced with emphasis on the mitigation strategies that have been developed and implemented in the field. SG degradation is presented from a world wide perspective as all countries operating PWRs have been effected to one degree or another. The paper is written from a US. perspective where the utility industry is currently undergoing tremendous change as a result of deregulation of the electricity marketplace. Competitive pressures are causing utilities to strive to reduce Operations and Maintenance (O ampersand M) and capital costs. SG corrosion is a major contributor to the O ampersand M costs of PWR plants, and therefore US utilities are evaluating and implementing the most cost effective solutions to their corrosion problems. Mitigation strategies developed over the past few years reflect a trend towards plant specific solutions to SG corrosion problems. Since SG degradation is in most cases an economic problem and not a safety problem, utilities can focus their mitigation strategies on their unique financial situation. Accordingly, the focus of R ampersand D has shifted from the development of more expensive, prescriptive solutions (e.g. reduced impurity limits) to corrosion problems to providing the utilities with a number of cost effective mitigation options (e.g. molar ratio control, boric acid treatment)

  2. Current density profile control by programming of gas puffing and plasma current waveform in the JIPPT-II tokamak

    International Nuclear Information System (INIS)

    Toi, K.; Itoh, S.; Kadota, K.; Kawahata, K.; Noda, N.

    1979-03-01

    In the resistive shell tokamak, JIPP T-II, the current density profile control is carried out by pre-programming of both gas puffing and plasma current waveform. The major disruptions are completely suppressed by the method and a high density tokamak plasma with low q(a) is obtained with better MHD stability, where the line-average electron density n sub(e) 13 cm -3 and safety factor at plasma surface q(a) >= 2.2. The control criterion that the current density profile is successfully controlled is derived as a function of the ratio of plasma current to the electron density I sub(p)/n sub(e) in the current rising phase, i.e., 20 x 10 -13 -13 kA.cm 3 . (author)

  3. Automatic analysis of signals during Eddy currents controls

    International Nuclear Information System (INIS)

    Chiron, D.

    1983-06-01

    A method and the corresponding instrument have been developed for automatic analysis of Eddy currents testing signals. This apparatus enables at the same time the analysis, every 2 milliseconds, of two signals at two different frequencies. It can be used either on line with an Eddy Current testing instrument or with a magnetic tape recorder [fr

  4. FPGA Control Implementation of a Grid-Connected Current-Controlled Voltage-Source Inverter

    Directory of Open Access Journals (Sweden)

    Rickard Ekström

    2013-01-01

    Full Text Available The full control system of a grid-connected current-controlled voltage-source inverter (CC-VSI has been designed and implemented on a field-programmable gate array (FPGA. Various control functions and implementation methods are described and discussed. The practical viability of the system is evaluated in an experimental setup, where a VSI supplies 30 kW into the local grid at 400 V. A phase-locked loop (PLL is used for grid phase tracking and evaluated for simulated abnormal grid conditions. Power factor is kept at unity, and the implemented control system is stressed with step responses in the supplied active power. A moving-average filter is implemented to reduce the effects of noise and harmonics on the current control loops. A coupling between active and reactive power flow is observed for the step responses but may be ignored in this context. The proposed system is fully comparable with more conventional microprocessor-based control systems.

  5. A linearly controlled direct-current power source for high-current inductive loads in a magnetic suspension wind tunnel

    Science.gov (United States)

    Tripp, John S.; Daniels, Taumi S.

    1990-01-01

    The NASA Langley 6 inch magnetic suspension and balance system (MSBS) requires an independently controlled bidirectional DC power source for each of six positioning electromagnets. These electromagnets provide five-degree-of-freedom control over a suspended aerodynamic test model. Existing power equipment, which employs resistance coupled thyratron controlled rectifiers as well as AC to DC motor generator converters, is obsolete, inefficient, and unreliable. A replacement six phase bidirectional controlled bridge rectifier is proposed, which employs power MOSFET switches sequenced by hybrid analog/digital circuits. Full load efficiency is 80 percent compared to 25 percent for the resistance coupled thyratron system. Current feedback provides high control linearity, adjustable current limiting, and current overload protection. A quenching circuit suppresses inductive voltage impulses. It is shown that 20 kHz interference from positioning magnet power into MSBS electromagnetic model position sensors results predominantly from capacitively coupled electric fields. Hence, proper shielding and grounding techniques are necessary. Inductively coupled magnetic interference is negligible.

  6. Control of Domain Wall Polarity by Current Pulses

    Science.gov (United States)

    Vanhaverbeke, A.; Bischof, A.; Allenspach, R.

    2008-09-01

    Direct observation of current-induced propagation of purely transverse magnetic domain walls with spin-polarized scanning electron microscopy is reported in Fe30Ni70 nanowires. After propagation, the domain walls keep their transverse nature but switch polarity in some cases. For uniform Ni70Fe30 wires, the effect is random and illustrates domain-wall propagation above the Walker threshold. In the case of Ni70Fe30/Fe wires, the transverse magnetization component in the wall is entirely determined by the polarity of the current pulse, an effect that is not reconciled by present theories even when taking into account the nonuniform Oersted field generated by the current.

  7. A Modified Droop Control Method for Parallel-Connected Current Source Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    In this paper, a novel control method was proposed for current source inverters under the grid-connected working mode. The control scheme is based on a modified droop control method, with an additional current reference signal that will be generated instead of the voltage reference. Hence......, there is only a current control loop with droop control in the whole control scheme without voltage control loop. So it is very suitable for grid-connected current source inverter which will simplify the design of the control scheme and combine the advantage of droop control. The parallel configuration...... is widely used to acquire high power demand, but the circulating current problem is a key issue that should be considered. In this paper, a simulation based on parallel current source inverters using the proposed control scheme is provided. Simulation results showed that a good circulating current...

  8. Concepts Concerning 'Disease\\' Causation, Control, and the current ...

    African Journals Online (AJOL)

    South African Family Practice. Journal Home · ABOUT THIS JOURNAL · Advanced Search · Current Issue · Archives · Journal Home > Vol 50, No 6 (2008) >. Log in or Register to get access to full text downloads.

  9. Micromagnetic analysis of geometrically controlled current-driven magnetization switching

    Directory of Open Access Journals (Sweden)

    O. Alejos

    2017-05-01

    Full Text Available The magnetization dynamics induced by current pulses in a pair of two “S-shaped” ferromagnetic elements, each one consisting on two oppositely tilted tapered spikes at the ends of a straight section, is theoretically studied by means of micromagnetic simulations. Our results indicate that the magnetization reversal is triggered by thermal activation, which assists the current-induced domain nucleation and the propagation of domain walls. The detailed analysis of the magnetization dynamics reveals that the magnetization switching is only achieved when a single domain wall is nucleated in the correct corner of the element. In agreement with recent experimental studies, the switching is purely dictated by the shape, being independent of the current polarity. The statistical study points out that successful switching is only achieved within a narrow range of the current pulse amplitudes.

  10. Optimized design of resonant controller for stator current harmonic compensation in DFIG wind turbine systems

    DEFF Research Database (Denmark)

    Liu, Changjin; Chen, Wenjie; Blaabjerg, Frede

    2012-01-01

    This paper presents an analytical method to optimize the parameters of resonant controller which is used in a Doubly-Fed Induction Generator (DFIG). In the DFIG control system, the fundamental current loop is controlled by PI-controllers, and the stator harmonic current loop is controlled...

  11. A grid side converter current controller for accurate current injection under normal and fault ride through operation

    DEFF Research Database (Denmark)

    Hadjidemetriou, Lenos; Kyriakides, Elias; Blaabjerg, Frede

    2013-01-01

    requirements. In addition, the renewable energy systems require fault ride through capability in order to support the power grid under balanced or unbalanced low voltage grid faults. Therefore, the development of advanced current controller techniques is essential for the grid side power electronic converters...... in order to increase the renewable energy systems penetration and satisfy the grid codes. This paper proposes a current controller technique, which enables the appropriate operation of the grid side converter under unbalanced grid faults and harmonic distorted grid conditions. The proposed current...... controller is designed using multiple synchronous reference frames and can inject full positive or full negative sequence balanced sinusoidal currents under abnormal grid conditions. The accurate performance with robustness against unbalanced and harmonic distorted grid voltage indicates that the proposed...

  12. Simulations of current density profile control using lower hybrid current drive in the TdeV tokamak

    International Nuclear Information System (INIS)

    Fuchs, V.; Bonoli, P.T.; Shkarofsky, I.P.; Cote, A.; Demers, Y.; Janicki, C.

    1995-01-01

    The physics basis of a simulation model for lower hybrid current drive (LHCD) is discussed. Issues associated with LH power deposition - wave propagation, mode conversion and cut-offs in toroidal geometry, as well as linear and quasi-linear Landau damping - are analysed. A simulation model (ACCOME) is applied to the LHCD experiment now operating on the Tokamak de Varennes (TdeV). The profiles and values of density and temperature needed as inputs to ACCOME are taken from the experiment. The predictions of current density and loop voltage from ACCOME are then compared with experimental LHCD results. Possible LH current profile control experiments are also analysed for TdeV using composite LH spectra to control the location of RF power deposition. Finally, the relevance of these current profile control results to future devices is discussed and an example is shown for ITER-like parameters. (author). 44 refs, 15 figs, 4 tabs

  13. A New Type Hi-Speed BLDC Control System Base on Indirect Current Control Strategy

    Science.gov (United States)

    Wang, D. P.; Wang, Y. C.; Zhang, F. G.; Jin, S.

    2017-05-01

    High speed BLDC has the characteristic as larger air gap smaller armature inductance, traditional PWM modulation will produce a great number of high frequency current harmonics which led problem like large torque ripple and serious motor heat. In the meantime traditional PWM modulation use the diode rectifier which cause harmonic pollution in electric power net. To solve the problem above, proposes a new motor controller topology. Using the IGBT device to replace the diode on frequency converter rectifier side, apply the power factor correction technology, reduce the pollution on the grid. Using busbar current modulation on the inverter, driving bridge-arm use 3-phase 6-state open as driving Mode, realize the control on a 10000r/min,10kw BLDC. The results of Simulation on matlab show the topological structure as proposed can effectively improve the network side power factor and reduce the motor armature winding harmonic and motor torque ripple.

  14. Distributed Secondary Control for DC Microgrid Applications with Enhanced Current Sharing Accuracy

    DEFF Research Database (Denmark)

    Lu, Xiaonan; Guerrero, Josep M.; Sun, Kai

    2013-01-01

    are used locally as the distributed secondary controllers in each converter to enhance the current sharing accuracy and restore the dc bus voltage simultaneously. All the controllers are realized locally and the LBC system is only used for changing the data of dc voltage and current. Thus, a decentralized......, a distributed secondary control method is proposed. Droop control is employed as the primary control method for load current sharing. Meanwhile, the dc output voltage and current in each module is transferred to the others by the low bandwidth communication (LBC) network. Average voltage and current controllers...

  15. Management and employee control in current industrial work

    DEFF Research Database (Denmark)

    Holt, Helle; Hvid, Helge

    2014-01-01

    This article examines how employee control is affected by the ongoing erosion of boundaries in work organization and established boundaries in the relationship between employees and management. One assumption is that the erosion of boundaries offers potential for increased employee control, meaning...... increased autonomy or self-determination at work (employee control how and when to do what). This assumption is supported by theories on the psychosocial working environment. Another assumption is that the erosion of boundaries threatens the frontiers from where employees can defend their interests......, and consequently reduces employees’ control of their work (what and how much to do). This assumption is supported by “labor process theory.” This article studies control and the erosion of boundaries in two case factories in the food industry. Two perspectives are applied: the psychosocial working environment...

  16. Designing single phase Current-Programmed-Controlled rectifiers by harmonic currents

    DEFF Research Database (Denmark)

    Andersen, Gert Karmisholt; Blaabjerg, Frede

    2002-01-01

    includes ramp compensation, different command current waveforms and the influence of the filter. One method show how the product of the inductance and the switching frequency determines the maximum power level the complies with IEC-61000-3-2. Design examples illustrate the possibilities of the presented...... design tool. The method is compared with simulated values as well with measured values and the calculations match very well....

  17. Pulse current gas metal arc welding characteristics, control and applications

    CERN Document Server

    Ghosh, Prakriti Kumar

    2017-01-01

    This monograph is a first-of-its-kind compilation on high deposition pulse current GMAW process. The nine chapters of this monograph may serve as a comprehensive knowledge tool to use advanced welding engineering in prospective applications. The contents of this book will prove useful to the shop floor welding engineer in handling this otherwise critical welding process with confidence. It will also serve to inspire researchers to think critically on more versatile applications of the unique nature of pulse current in GMAW process to develop cutting edge welding technology.

  18. Current status of fertility control methods in India

    Indian Academy of Sciences (India)

    Use of the condom increased to 3.1% from 2.4%. There is an urgent need for research to develop new contraceptive modalities especially for men and also for women and to make existing methods more safe, affordable and acceptable. Current efforts in India to develop a male contraceptive are mainly directed towards.

  19. DSP based adaptive hysteresis-band current controlled active filter ...

    African Journals Online (AJOL)

    The use of non-linear loads critically affects the quality of supply by drawing harmonic currents and reactive power from the electrical distribution system. Active power filters are the most viable solution for solving such power quality problems in compliance with the harmonic standards. This article presents a digital signal ...

  20. A differential-delay control for ramped magnet current

    Energy Technology Data Exchange (ETDEWEB)

    Murray, J. [State Univ. of New York, Stony Brook, NY (United States). Dept. of Electrical Engineering; Olsen, R. [Brookhaven National Lab., Upton, NY (United States)

    1992-11-01

    A differential-delay control system has been designed and implemented for the main dipole magnet power supply of the booster ring at the National Synchrotron Light Source at Brookhaven National Lab. The control algorithm was implemented on a floating-point digital signal processor; in tests, the use of digital signal-processing techniques gave a factor of ten improvement in the tracking response time, together with a modest improvement in tracking accuracy.

  1. A differential-delay control for ramped magnet current

    Energy Technology Data Exchange (ETDEWEB)

    Murray, J. (State Univ. of New York, Stony Brook, NY (United States). Dept. of Electrical Engineering); Olsen, R. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    A differential-delay control system has been designed and implemented for the main dipole magnet power supply of the booster ring at the National Synchrotron Light Source at Brookhaven National Lab. The control algorithm was implemented on a floating-point digital signal processor; in tests, the use of digital signal-processing techniques gave a factor of ten improvement in the tracking response time, together with a modest improvement in tracking accuracy.

  2. Controlling charge current through a DNA based molecular transistor

    Energy Technology Data Exchange (ETDEWEB)

    Behnia, S., E-mail: s.behnia@sci.uut.ac.ir; Fathizadeh, S.; Ziaei, J.

    2017-01-05

    Molecular electronics is complementary to silicon-based electronics and may induce electronic functions which are difficult to obtain with conventional technology. We have considered a DNA based molecular transistor and study its transport properties. The appropriate DNA sequence as a central chain in molecular transistor and the functional interval for applied voltages is obtained. I–V characteristic diagram shows the rectifier behavior as well as the negative differential resistance phenomenon of DNA transistor. We have observed the nearly periodic behavior in the current flowing through DNA. It is reported that there is a critical gate voltage for each applied bias which above it, the electrical current is always positive. - Highlights: • Modeling a DNA based molecular transistor and studying its transport properties. • Choosing the appropriate DNA sequence using the quantum chaos tools. • Choosing the functional interval for voltages via the inverse participation ratio tool. • Detecting the rectifier and negative differential resistance behavior of DNA.

  3. The TS 600: automatic control system for eddy currents

    International Nuclear Information System (INIS)

    Poulet, J.P.

    1986-10-01

    In the scope of fabrication and in service inspection of the PWR steam generator tubing bendle, FRAMATOME developed an automatic Eddy Current testing system: TS600. Based on a mini-computer, TS600 allows to digitize, to store and to process data in various ways, so it is possible to perform several kinds of inspection: conventional inservice inspection, roll area profilometry...... TS600 can also be used to develop new methods of examination [fr

  4. Electric field control photo-induced Hall currents in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M. Idrish [Nanoscale Science and Technology Centre, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Department of Physics, University of Chittagong, Chittagong, Chittagong 4331 (Bangladesh)], E-mail: m.miah@griffith.edu.au

    2008-10-15

    We generate spin-polarized carrier populations in GaAs and low temperature-grown GaAs (LT-GaAs) by circularly polarized optical beams and pull them by external electric fields to create spin-polarized currents. In the presence of the optically generated spin currents, anomalous Hall currents with an enhancement with increasing doping are observed and found to be almost steady in moderate electric fields up to {approx}120 mV {mu}m{sup -1}, indicating that photo-induced spin orientation of electrons is preserved in these systems. However, a field {approx}300 mV {mu}m{sup -1} completely destroys the electron spin polarization due to an increase of the D'yakonov-Perel' spin precession frequency of the hot electrons. This suggests that high field carrier transport conditions might not be suitable for spin-based technology with GaAs and LT-GaAs. It is also demonstrated that the presence of the excess arsenic sites in LT-GaAs might not affect the spin relaxation by Bir-Aronov-Pikus mechanism owing to a large number of electrons in n-doped materials.

  5. Current-Controlled Current-Mode Universal Biquad Employing Multi-Output Transconductors

    Directory of Open Access Journals (Sweden)

    R. Sotner

    2009-09-01

    Full Text Available This paper deals with RC active biquad working in the so-called current mode (CM. The design approach uses only three transconductors (OTA with the minimum necessary number of outputs and with only three passive grounded elements. The proposed filter has simple circuit configuration providing all standard transfer functions such as high-pass (HP, band-pass (BP, low-pass (LP, band-reject (BR and all-pass (AP. Electronic tuning and independent adjusting of the quality factor and bandwidth of BP filter is possible. The presented circuits are verified by PSpice simulations utilizing OTAs on transistor level of abstraction. The linear parasitic effects of the real active elements in each suggested circuit are briefly discussed. Experimental verification is also given. Designed networks can be used in many applications such as antialiasing filters, in high-speed data telecommunication systems, for signal processing in the cable modems, in regulation and measurement techniques etc.

  6. Current status of the controlled atmosphere storage in Nigeria ...

    African Journals Online (AJOL)

    Controlled atmosphere (CA) storage of food crops was introduced to Nigeria in 1978 in co-operative agreement between Snamprogetti/Assoreni of Italy and the Nigerian Stored Products Research Institute (NSPRI). Collaborative research between Assoreni and NSPRI from 1979-1981, and by NSPRI from 1982 to date on ...

  7. Regional Seminars to Address Current Nuclear Export Control Issues

    International Nuclear Information System (INIS)

    Killinger, Mark H.

    2002-01-01

    The control of nuclear-related exports, a critical component of the nonproliferation regime, is facing several opportunities and challenges. As countries sign and ratify the International Atomic Energy Agency's (IAEA) safeguards Additional Protocol (AP), they will begin to report far more export information, including exports of a list of items similar to the Nuclear Supplier Group's Trigger List that existed when the AP was developed in the mid-1990s. This positive development contrasts with challenges such as globalization, transshipments, and tracking of end-uses. Pacific Northwest National Laboratory is proposing that the US Department of Energy (DOE) develop regional seminars that address these types of issues related to export/import controls. The DOE seminars would be designed to supplement regional seminars sponsored by the IAEA and member states on topics related to the Additional Protocol (referred to as 'IAEA seminars'). The topic of nuclear export/import controls is not thoroughly addressed in the IAEA seminars. The proposed DOE seminars would therefore have two objectives: familiarizing countries with the export/import provisions of the Additional Protocol, and addressing challenges such as those noted above. The seminars would be directed particularly at countries that have not ratified the AP, and at regions where export-related problems are particularly prevalent. The intent is to encourage governments to implement more effective nuclear export control systems that meet the challenges of the 21st century.

  8. Enhancing the Frequency Adaptability of Periodic Current Controllers for Grid-Connected Power Converters

    OpenAIRE

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2015-01-01

    It is mandatory for grid-connected power converters to synchronize the feed-in currents with the grid. Moreover, the power converters should produce feed-in currents with low total harmonic distortions according to the demands, by employing advanced current controllers, e.g., Proportional Resonant (PR) and Repetitive Controllers (RC). The synchronization is actually to detect the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is c...

  9. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  10. Ring Current He Ion Control by Bounce Resonant ULF Waves

    Science.gov (United States)

    Kim, Hyomin; Gerrard, Andrew J.; Lanzerotti, Louis J.; Soto-Chavez, Rualdo; Cohen, Ross J.; Manweiler, Jerry W.

    2017-12-01

    Ring current energy He ion (˜65 keV to ˜520 keV) differential flux data from the Radiation Belt Storm Probe Ion Composition Experiment (RBSPICE) instrument aboard the Van Allan Probes spacecraft show considerable variability during quiet solar wind and geomagnetic time periods. Such variability is apparent from orbit to orbit (˜9 h) of the spacecraft and is observed to be ˜50-100% of the nominal flux. Using data from the Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) instrument, also aboard the Van Allen Probes spacecraft, we identify that a dominant source of this variability is from ULF waveforms with periods of tens of seconds. These periods correspond to the bounce resonant timescales of the ring current He ions being measured by RBSPICE. A statistical survey using the particle and field data for one full spacecraft precession period (approximately 2 years) shows that the wave and He ion flux variations are generally anticorrelated, suggesting the bounce resonant pitch angle scattering process as a major component in the scattering of He ions.

  11. Current status of patient-controlled analgesia in cancer patients.

    Science.gov (United States)

    Ripamonti, C; Bruera, E

    1997-03-01

    Patient-controlled analgesia (PCA) is a relatively new technique in which patients are able to self-administer small doses of opioid analgesics when needed. Many different devices are available for opioid infusion, including a syringe pump, disposable plastic cylinder, and battery-operated computer-driven pump. These devices allow patients to choose an intermittent (demand) bolus, continuous infusion, or both modes of administration. Parameters, such as route, drug concentration dose, frequency, and maximum daily or hourly dose, are programmed by the physician. The patient decides whether or not to take a dose. Devices can be used to deliver the drug into a running intravenous infusion, the epidural space, or subcutaneously. Controlled trials indicate that PCA is probably superior to regular opioid administration in postoperative pain. Reported advantages include greater patient satisfaction, decreased sedation and anxiety, and reduced nursing time and hospitalization. Preliminary experience suggests that PCA is also useful and safe for cancer pain, but further research is greatly needed.

  12. The SARE tool for rabies control: Current experience in Ethiopia.

    Science.gov (United States)

    Coetzer, A; Kidane, A H; Bekele, M; Hundera, A D; Pieracci, E G; Shiferaw, M L; Wallace, R; Nel, L H

    2016-11-01

    The Stepwise Approach towards Rabies Elimination (SARE) tool was developed through a joint effort of the Food and Agriculture Organization (FAO) of the United Nations and the Global Alliance for Rabies Control (GARC), to provide a standard mechanism for countries to assess their rabies situation and measure progress in eliminating the disease. Because the African continent has the highest per capita death rate from rabies, and Ethiopia is estimated to have the second largest number of rabies deaths of all African countries, Ethiopia undertook a self-assessment by means of the Stepwise Approach towards Rabies Elimination (SARE) tool. In February 2016, the Ethiopian government hosted an intersectoral consultative meeting in an effort to assess the progress that has been made towards the control and elimination of canine rabies. The SARE assessment identified a number of critical gaps, including poor inter-sectoral collaboration and limited availability and access to dog vaccine, while the existence of a surveillance system for rabies and legislation for outbreak declaration and response were among the strengths identified. The SARE tool enabled key criteria to be prioritized, thereby accelerating the National Strategy and ensuring that Ethiopia will progress rapidly in line with the goals set by the global community for the elimination of human rabies deaths by 2030. Although the analysis showed that Ethiopia is still in the early stages of rabies control (Stage 0.5/5), the country shows great promise in terms of developing a SARE-guided National Rabies Prevention and Control Strategy. Copyright © 2016 Elsevier B.V. All rights reserved.

  13. Current status and control of rabies in Perú

    OpenAIRE

    Navarro V, Ana María; Componente Especial de Control de Zoonosis, Dirección General de Salud de las Personas, Ministerio de Salud. Lima, Perú. Médico Veterinario.; Bustamante N, José; Componente Especial de Control de Zoonosis, Dirección General de Salud de las Personas, Ministerio de Salud. Lima, Perú. Médico Veterinario.; Sato S, Alberto; Facultad de Medicina Veterinaria, Universidad Nacional Mayor de San Marcos. Lima, Perú. Médico Veterinario.

    2007-01-01

    Rabies is an endemic disease of Peru, that appears in two cycles, one urban related with transmission by dog, and another wild caused mainly by vampires bats bite. Most of human cases of the last decades they have been by urban rabies, nevertheless the used measures of control (canine vaccine campaigns, vaccine production, identification of biting dog, opportune attention of the victim and surveillance and notification system) they have managed to reduce the incidence of canine rabies and ...

  14. Open-Delta Three-Phase Inverter Current Control Using Predictive Control For PV System Connected To The Grid

    OpenAIRE

    ABBASİ, Zohre; FESHKİ FARAHANİ, Hassan

    2015-01-01

    Abstract. Predictive control method has advantages such as simple structure, functional and follow the simple mathematical. In this paper, a new method is provided for controlling the open-Delta three-phase inverter . Model-based predictive control system is used for controlling the current of a open-Delta three-phase inverter, which is in the process of converting the photovoltaic energy conversion plays a three-phase network. The controller at any time, the next period current are estimated...

  15. Glycemic control in cardiac surgery: Rationale and current evidence

    Directory of Open Access Journals (Sweden)

    G Girish

    2014-01-01

    Full Text Available Studies in cardiac surgical patients have shown an association of hyperglycemia with increased incidences of sepsis, mediastinitis, prolonged mechanical ventilation, cardiac arrhythmias and longer intensive care and hospital stay. There is considerable controversy regarding appropriate glycemic management in these patients and in the definition of hyperglycemia and hypoglycemia or the blood sugar levels at which therapy should be initiated. There is also dilemma regarding the usage of "tight glycemic control" with studies showing conflicting evidences. Part of the controversy can be explained by the differing designs of these studies and the variable definitions of hyperglycemia and hypoglycemia.

  16. Enhancing the Frequency Adaptability of Periodic Current Controllers for Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2015-01-01

    It is mandatory for grid-connected power converters to synchronize the feed-in currents with the grid. Moreover, the power converters should produce feed-in currents with low total harmonic distortions according to the demands, by employing advanced current controllers, e.g., Proportional Resonant...... controllers are investigated by analyzing the frequency adaptability of these current controllers. Subsequently, strategies to enhance the frequency variation immunity for the current controllers are proposed for the power converters to produce high quality feed-in currents even in the presence of frequency...... (PR) and Repetitive Controllers (RC). The synchronization is actually to detect the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is commonly performed by a Phase-Locked-Loop (PLL) system. As a consequence, harmonics and deviations...

  17. Harmonic current control for LCL-filtered VSCs connected to ultra-weak grids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Yang, Dongsheng; Blaabjerg, Frede

    2017-01-01

    control scheme is thus proposed by feeding back the filter capacitor voltage and the converter-side current. The method not only stabilizes the harmonic current control with a wide range of SCR values, but also mitigates harmonic distortions in the grid-side current of the VSC. The stabilizing mechanism......This paper addresses the harmonic current control for LCL-filtered Voltage-Source Converters (VSCs) connected to ultra-weak (high-impedance) grids. It is shown that the harmonic current controllers tend to be unstable as the Short-Circuit Ratio (SCR) of the system reduces. An active stabilizing...

  18. Electronically Tunable Current Controlled Current Conveyor Transconductance Amplifier-Based Mixed-Mode Biquadratic Filter with Resistorless and Grounded Capacitors

    Directory of Open Access Journals (Sweden)

    Hua-Pin Chen

    2017-03-01

    Full Text Available A new electronically tunable mixed-mode biquadratic filter with three current controlled current conveyor transconductance amplifiers (CCCCTAs and two grounded capacitors is proposed. With current input, the filter can realise lowpass (LP, bandpass (BP, highpass (HP, bandstop (BS and allpass (AP responses in current mode and LP, BP and HP responses in transimpedance mode. With voltage input, the filter can realise LP, BP, HP, BS and AP responses in voltage and transadmittance modes. Other attractive features of the mixed-mode biquadratic filter are (1 the use of two grounded capacitors, which is ideal for integrated circuit implementation; (2 orthogonal control of the quality factor (Q and resonance angular frequency (ωo for easy electronic tenability; (3 low input impedance and high output impedance for current signals; (4 high input impedance for voltage signal; (5 avoidance of need for component-matching conditions; (6 resistorless and electronically tunable structure; (7 low active and passive sensitivities; and (8 independent control of the voltage transfer gains without affecting the parameters ωo and Q.

  19. Coherent control of single electrons: a review of current progress.

    Science.gov (United States)

    Bäuerle, Christopher; Christian Glattli, D; Meunier, Tristan; Portier, Fabien; Roche, Patrice; Roulleau, Preden; Takada, Shintaro; Waintal, Xavier

    2018-01-22

    In this report we review the present state of the art of the control of propagating quantum states at the single-electron level and its potential application to quantum information processing. We give an overview of the different approaches that have been developed over the last few years in order to gain full control over a propagating single-electron in a solid-state system. After a brief introduction of the basic concepts, we present experiments on flying qubit circuits for ensemble of electrons measured in the low frequency (DC) limit. We then present the basic ingredients necessary to realise such experiments at the single-electron level. This includes a review of the various single-electron sources that have been developed over the last years and which are compatible with integrated single-electron circuits. This is followed by a review of recent key experiments on electron quantum optics with single electrons. Finally we will present recent developments in the new physics that has emerged using ultrashort voltage pulses. We conclude our review with an outlook and future challenges in the field.

  20. Current status and strategies for hepatitis B control in Korea

    Directory of Open Access Journals (Sweden)

    Eun Ju Cho

    2017-09-01

    Full Text Available Hepatitis B virus (HBV infection is the most common cause of chronic liver diseases in Korea. After the introduction of the universal HBV vaccination program, the prevalence of hepatitis B surface antigen was markedly reduced, and Korea is now classified as an area of intermediate endemicity for HBV. However, there are still hurdles for elimination of hepatitis B, such as immunoprophylaxis failure against vertical transmission, occurrence of acute hepatitis B among peoples who did not have vaccination at younger age, and rapid increase of immigrant populations from HBV endemic areas. To achieve the World Health Organization goal of viral hepatitis elimination by 2030 in Korea, we suggest comprehensive policies for more effective control of hepatitis B as following: i insurance coverage for antiviral prophylaxis in mothers with high viremia, ii screening for hepatitis B seromarkers and catch-up HBV vaccinations of susceptible persons with hepatitis B, iii establishment of an independent 'viral hepatitis sector' in Centers for Disease Control & Prevention to organize and execute comprehensive strategy for management of viral hepatitis, iv encourage of management of HBV infection in immigrant populations, v national campaign to promote awareness of hepatitis B.

  1. Coherent control of single electrons: a review of current progress

    Science.gov (United States)

    Bäuerle, Christopher; Glattli, D. Christian; Meunier, Tristan; Portier, Fabien; Roche, Patrice; Roulleau, Preden; Takada, Shintaro; Waintal, Xavier

    2018-05-01

    In this report we review the present state of the art of the control of propagating quantum states at the single-electron level and its potential application to quantum information processing. We give an overview of the different approaches that have been developed over the last few years in order to gain full control over a propagating single-electron in a solid-state system. After a brief introduction of the basic concepts, we present experiments on flying qubit circuits for ensemble of electrons measured in the low frequency (DC) limit. We then present the basic ingredients necessary to realise such experiments at the single-electron level. This includes a review of the various single-electron sources that have been developed over the last years and which are compatible with integrated single-electron circuits. This is followed by a review of recent key experiments on electron quantum optics with single electrons. Finally we will present recent developments in the new physics that has emerged using ultrashort voltage pulses. We conclude our review with an outlook and future challenges in the field.

  2. Digital peak current mode control with adaptive slope compensation for DC-DC converters

    DEFF Research Database (Denmark)

    Andersen, Karsten Holm; Nymand, Morten

    2017-01-01

    This paper presents an adaptive slope compensation method for peak current mode control of digital controlled DC-DC converters, which controls the quality factor of the complex conjugated poles at half the switching frequency. Using quality factor control enables optimization of the dynamic...... performance and stability of current mode control. The presented method adapt to DC-DC converter operating conditions by estimating the rising and falling inductor current slopes, to apply a current slope compensation value to obtain a constant quality factor. The experimental results verifies the theoretical...

  3. Heating, current drive and MHD control using ECH in TCV

    International Nuclear Information System (INIS)

    Goodman, T.

    2001-01-01

    The 6 beam 2nd harmonic X-mode (X2), 3MW, ECH/ECCD system of the TCV tokamak allows a fine tailoring of the deposition profiles in the plasma. The sensitivity of the sawtooth period to the deposition location is used to increase the equilibria reconstruction and ray-tracing accuracy. Off-axis ECH, followed by on-axis counter-ECCD produces improved central confinement regimes in which τ Ee exceeds RLW scaling by a factor of 3.5. The PRETOR transport code (incorporating an RLW local transport model but constrained by the experimental density profiles) predicts an extreme sensitivity of τ Ee to the deposition location of the counter-ECCD. This is confirmed by experiments. Sawtooth simulations using PRETOR, including the effects of current drive with inputs from the TORAY ray-tracing code, are in good agreement with experimental results. These results are an initial benchmark for the package of analysis codes, LIUQE/TORAY/PRETOR used during ECH/ECCD experiments on TCV. (author)

  4. Chemopreventive opportunities to control basal cell carcinoma: Current perspectives.

    Science.gov (United States)

    Tilley, Cynthia; Deep, Gagan; Agarwal, Rajesh

    2015-09-01

    Basal cell carcinoma (BCC) is a major health problem with approximately 2.8 million new cases diagnosed each year in the United States. BCC incidences have continued to rise due to lack of effective chemopreventive options. One of the key molecular characteristics of BCC is the sustained activation of hedgehog signaling through inactivating mutations in the tumor suppressor gene patch (Ptch) or activating mutations in Smoothened. In the past, several studies have addressed targeting the activated hedgehog pathway for the treatment and prevention of BCC, although with toxic effects. Other studies have attempted BCC chemoprevention through targeting the promotional phase of the disease especially the inflammatory component. The compounds that have been utilized in pre-clinical and/or clinical studies include green and black tea, difluoromethylornithine, thymidine dinucleotide, retinoids, non-steroidal anti-inflammatory drugs, vitamin D3, and silibinin. In this review, we have discussed genetic and epigenetic modifications that occur during BCC development as well as the current state of BCC pre-clinical and clinical chemoprevention studies. © 2015 Wiley Periodicals, Inc.

  5. Direct Torque Control in presence of Current sensor failure in Variable Speed Wind System: Effect analysis, detection and control reconfiguration

    Directory of Open Access Journals (Sweden)

    A. J. Arbi

    2008-03-01

    Full Text Available This paper presents a study of current sensor failure in a Direct Torque Control applied to a Double Fed Induction Generator based Variable Speed Wind System. The effect of scaling and offset current sensor errors is discussed through sensibility analysis. A control reconfiguration is then proposed to remedy this sensor failure. Simulation results emphasize the good performances of the proposed current sensor fault tolerant control

  6. Resistive flux saving and current profile control during lower hybrid waves assisted current rise in TORE SUPRA

    International Nuclear Information System (INIS)

    van Houtte, D.; Hoang, G.T.; Joffrin, E.; Lecoustey, P.; Moreau, D.; Parlange, F.; Tonon, G.; Vallet, J.C.

    1992-01-01

    Resistive flux saving at densities n e = (1 - 2) x 10 19 m -3 has been studied. High flux saving efficiency (0.7 x 10 13 Wb/J/m -1 ) can be achieved for a low rf power (P LH = 0.5 MW) due to the beneficial effect of the electric field on the suprathermal electrons. However for power higher than 1 MW, the efficiency is 0.25 x 10 13 Wb/J/m -1 . This flux saving efficiency is comparable to the one obtained during the flat top phase. The application of the LH power during a low density current ramp-up tends to peak the electron temperature and current density profiles. The rf power level, the parallel wavenumber and the current ramp rate allow to control the trajectories of the plasma discharges during the current rise inside the MHD stable domain

  7. Control of AC–DC grid side converter with single AC current sensor

    Indian Academy of Sciences (India)

    Conventionally, two AC side current sensors are needed in vector control of grid side converter for AC–DC bidirectional power conversion. The present paper proposes a technique where the control can be achieved with the use of only one AC side current sensor. The control principle utilises the information of ...

  8. Speed Control Analysis of Brushless DC Motor Based on Maximum Amplitude DC Current Feedback

    Directory of Open Access Journals (Sweden)

    Hassan M.A.A.

    2014-07-01

    Full Text Available This paper describes an approach to develop accurate and simple current controlled modulation technique for brushless DC (BLDC motor drive. The approach is applied to control phase current based on generation of quasi-square wave current by using only one current controller for the three phases. Unlike the vector control method which is complicated to be implemented, this simple current modulation technique presents advantages such as phase currents are kept in balance and the current is controlled through only one dc signal which represent maximum amplitude value of trapezoidal current (Imax. This technique is performed with Proportional Integral (PI control algorithm and triangular carrier comparison method to generate Pulse Width Modulation (PWM signal. In addition, the PI speed controller is incorporated with the current controller to perform desirable speed operation of non-overshoot response. The performance and functionality of the BLDC motor driver are verified via simulation by using MATLAB/SIMULINK. The simulation results show the developed control system performs desirable speed operation of non-overshoot and good current waveforms.

  9. [Current problems in the microbiological control of food].

    Science.gov (United States)

    Campello, C

    1989-01-01

    The paper deals with a number of aspects of current interest and significance on the subject of the microbiological testing of food with particular reference to the role of research institutes. The main objectives of microbiological testing of food are essentially two: (i) to establish the absence of a human health hazard due to microbial contamination of food (food safety); and (ii) to define the quality standard of food (food quality). As far as the first of these objectives is concerned, the outcome of the assay necessarily emerges not only from identification of pathogens but also from definition of their pathogenicity and virulence characteristics and of critical factors for their transmission. Alongside the classic pathogens, evidence has recently been found indicating that four additional bacteria, namely Yersinia enterocolitica, Campylobacter jejuni, Vibrio cholerae non 0-1 and Listeria monocytogenes, also play an important role in food-borne disease. The most characteristic biological, ecological and epidemiologic aspects related to human food-borne disease are described for these bacteria. As regards the second objective, i.e. food quality, stress is laid on the role played by microbial indicators and their predictivity for pathogenic micro-organisms, which does not always exist. This depends on three basic differential factors: (i) biological characteristics giving rise to different diffusion, dilution and extinction phenomena, or, on the other hand, multiplication of such pathogens in the environment and in food; (ii) resistance to the natural inactivation mechanisms, whether of a general or specific nature, of each alimentary substrate; and (iii) the ecological and epidemiological pattern. By way of examples, two experiences indicating the lack of predictivity of the faecal indicators for enterovirus and Vibrio cholerae non 0-1 are reported. Nevertheless, standard microbiological testing for mesophilic flora and indicators are fundamental instruments

  10. Current knowledge on groundwater microbial pathogens and their control

    Science.gov (United States)

    Macler, Bruce A.; Merkle, Jon C.

    Those who drink groundwater that has not been disinfected are at increased risk of infection and disease from pathogenic microorganisms. Recent studies have shown that up to half of all US drinking-water wells tested had evidence of fecal contamination. A significant fraction of all waterborne disease outbreaks is associated with groundwater. An estimated 750,000 to 5.9million illnesses per year result from contaminated groundwaters in the US. Mortality from these illnesses may be 1400-9400 deaths per year. Control of these pathogens starts with source-water protection activities to prevent fecal contamination of aquifers and wells. These include assessment of wellhead vulnerability to fecal contamination and correction of identified deficiencies. Correction may include control of sources or rehabilitation of the well itself. Disinfection can serve as a useful barrier and is recommended as a prudent public-health policy for all groundwater systems. Ceux qui boivent une eau souterraine non désinfectée présentent un risque accru d'infection et de maladie par des germes pathogènes. De récentes études ont montré que près de la moitié de tous les puits américains testés, captés pour l'eau potable, sont soumis à une contamination fécale. Une fraction significative de l'ensemble des premières manifestations de maladies liées à l'eau est associée aux eaux souterraines. On estime qu'entre 750 000 et 5,9millions de personnes sont malades chaque année aux États-Unis à cause d'eaux souterraines polluées. La mortalité parmi ces malades doit ètre de l'ordre de 1400 à 9400 décès par an. La protection contre ces germes pathogènes commence avec des mesures prises au niveau du captage pour empècher la pollution des aquifères et des puits. Celles-ci comprennent une évaluation de la vulnérabilité des tètes de puits à la pollution fécale et une correction des insuffisances mises en évidence. Cette correction peut comprendre une maîtrise des sources

  11. A Coordinate Control Strategy for Circulating Current Suppression in Multiparalleled Three-Phase Inverters

    DEFF Research Database (Denmark)

    Zhang, Xueguang; Wang, Tianyi; Wang, Xiongfei

    2017-01-01

    This paper addresses the zero-sequence circulating current control in the multiparalleled three-phase voltage-source inverters. The model of the zero-sequence circulating current in the N-paralleled (N ≥ 3) inverters is derived. It is shown that the circulating current is not only susceptible...... to the mismatches of circuit parameters, but it is also influenced by the interactions of circulating current controllers used by other paralleled inverters. To eliminate these adverse effects on the circulating current control loop, a coordinate control strategy for the N-paralleled inverter is proposed based...... on the zero-vector feedforward method with the space-vector pulse width modulation. Moreover, a virtual inverter method is introduced to facilitate the implementation of the proposed controller, which decouples the interactions of circulating current controllers in the paralleled inverters. Finally...

  12. A current controlled matrix converter for wind energy conversion systems based on permanent magnet synchronous generator

    OpenAIRE

    Naggar H. Saad; Ahmed A. El-Sattar; Mohamed I. Marei

    2016-01-01

    The main challenges of wind energy conversion systems (WECS) are to maximize the energy capture from the wind and injecting reactive power during the fault. This paper presents a current controlled matrix converter to interface Permanent Magnet Synchronous Generators (PMSG) based WECS with the grid. To achieve fast dynamic response with reduced current ripples, a hysteresis current control is utilized. The proposed control system decouples the active and reactive components of the PMSG curren...

  13. An improved current control scheme for grid-connected DG unit based distribution system harmonic compensation

    DEFF Research Database (Denmark)

    He, Jinwei; Wei Li, Yun; Wang, Xiongfei

    2013-01-01

    In order to utilize DG unit interfacing converters to actively compensate distribution system harmonics, this paper proposes an enhanced current control approach. It seamlessly integrates system harmonic mitigation capabilities with the primary DG power generation function. As the proposed current...... the fundamental current reference. The proposed power control scheme effectively eliminates the impacts of steady-state fundamental current tracking errors in the DG units. Thus, an accurate power control is realized even when the harmonic compensation functions are activated. Experimental results from a single...... controller has two well decoupled control branches to independently control fundamental and harmonic DG currents, phase-locked loops (PLL) and system harmonic component extractions can be avoided during system harmonic compensation. Moreover, a closed-loop power control scheme is also employed to derive...

  14. New Gain Controllable Resistor-less Current-mode First Order Allpass Filter and its Application

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-04-01

    Full Text Available New first order allpass filter (APF in current mode, constructed from 2 CCCCTAs and grounded capacitor, is presented. The current gain and phase shift can be electronically /orthogonally controlled. Low input and high output impedances are achieved which make the circuit to be easily cascaded to the current-mode circuit without additional current buffers. The operation of the proposed filter has been verified through simulation results which confirm the theoretical analysis. The application example as current-mode quadrature oscillator with non-interactive current control for both of oscillation condition and oscillation frequency is included to show the usability of the proposed filter.

  15. Load Torque Compensator for Model Predictive Direct Current Control in High Power PMSM Drive Systems

    DEFF Research Database (Denmark)

    Preindl, Matthias; Schaltz, Erik

    2010-01-01

    the use of a current controller which takes into account the discrete states of the inverter, e.g. DTC or a more modern approach: Model Predictive Direct Current Control (MPDCC). Moreover overshoots and oscillations in the speed are not desired in many applications, since they lead to mechanical stress......In drive systems the most used control structure is the cascade control with an inner torque, i.e. current and an outer speed control loop. The fairly small converter switching frequency in high power applications, e.g. wind turbines lead to modest speed control performance. An improvement bring...... behaviour. It compensates the load torque influence on the speed control setting a feed forward torque value, i.e. current reference value. The benefits are twice. The speed controller reaches immediately the speed reference value avoiding offsets which must be compensated by the weak integrator. Moreover...

  16. Disturbance estimator based predictive current control of grid-connected inverters

    OpenAIRE

    Al-Khafaji, Ahmed Samawi Ghthwan

    2013-01-01

    ABSTRACT: The work presented in my thesis considers one of the modern discrete-time control approaches based on digital signal processing methods, that have been developed to improve the performance control of grid-connected three-phase inverters. Disturbance estimator based predictive current control of grid-connected inverters is proposed. For inverter modeling with respect to the design of current controllers, we choose the d-q synchronous reference frame to make it easier to understand an...

  17. Complex state variable- and disturbance observer-based current controllers for AC drives

    DEFF Research Database (Denmark)

    Dal, Mehmet; Teodorescu, Remus; Blaabjerg, Frede

    2013-01-01

    , extracted by a disturbance observer and then injected into the current controller. In this study, a revised version of a disturbance observer-based controller and a well known complex variable model-based design with a single set of complex pole are compared in terms of design aspects and performance......In vector-controlled AC drives, the design of current controller is usually based on a machine model defined in synchronous frame coordinate, where the drive performance may be degraded by both the variation of the machine parameters and the cross-coupling between the d- and q-axes components...... of the stator current. In order to improve the current control performance an alternative current control strategy was proposed previously aiming to avoid the undesired cross-coupling and non-linearities between the state variables. These effects are assumed as disturbances arisen in the closed-loop path...

  18. Robust Current Control of Doubly Fed Wind Turbine Generator under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Wang, Yun; Gong, Wenming; Wu, Qiuwei

    2014-01-01

    This paper presents the design of a H ∞ current controller for doubly fed induction generators (DFIGs) in order to maintain stable operation under unbalanced voltage conditions. The H ∞ current controller has a multi-input and multi-output (MIMO) structure and is designed using the loop shaping...

  19. All-electric-controlled spin current switching in single-molecule magnet-tunnel junctions

    Science.gov (United States)

    Zhang, Zheng-Zhong; Shen, Rui; Sheng, Li; Wang, Rui-Qiang; Wang, Bai-Gen; Xing, Ding-Yu

    2011-04-01

    A single-molecule magnet (SMM) coupled to two normal metallic electrodes can both switch spin-up and spin-down electronic currents within two different windows of SMM gate voltage. Such spin current switching in the SMM tunnel junction arises from spin-selected single electron resonant tunneling via the lowest unoccupied molecular orbit of the SMM. Since it is not magnetically controlled but all-electrically controlled, the proposed spin current switching effect may have potential applications in future spintronics.

  20. An Improved Current Control Strategy for a Grid-Connected Inverter under Distorted Grid Conditions

    OpenAIRE

    Ngoc Bao Lai; Kyeong-Hwa Kim

    2016-01-01

    This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. The main challenge associated with the grid-connected inverter in distributed generation (DG) systems is to maintain the harmonic contents in output current below the specified values even when the grid is subject to uncertain disturbances such as harmonic distortion. To overcome such a challenge, an improved current control scheme is proposed for a grid-connecte...

  1. High Performance Current Controller for Selective Harmonic Compensation in Active Power Filters

    DEFF Research Database (Denmark)

    Lascu, Cristian; Asiminoaei, Lucian; Boldea, I.

    2007-01-01

    A new current control scheme for selective harmonic compensation is proposed for shunt active power filters. The method employs an array of resonant current controllers, one for the fundamental, and one for each harmonic, implemented in fundamental reference frame in order to reduce the overall...... computational effort. The proposed controller design is based on the pole-zero cancellation technique, taking into account the load transfer function at each harmonic frequency. Two design methods are provided, which give controller transfer functions with superior frequency response. The complete current...

  2. Design of Nonlinear Robust Rotor Current Controller for DFIG Based on Terminal Sliding Mode Control and Extended State Observer

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2014-01-01

    Full Text Available As to strong nonlinearity of doubly fed induction generators (DFIG and uncertainty of its model, a novel rotor current controller with nonlinearity and robustness is proposed to enhance fault ride-though (FRT capacities of grid-connected DFIG. Firstly, the model error, external disturbances, and the uncertain factors were estimated by constructing extended state observer (ESO so as to achieve linearization model, which is compensated dynamically from nonlinear model. And then rotor current controller of DFIG is designed by using terminal sliding mode variable structure control theory (TSMC. The controller has superior dynamic performance and strong robustness. The simulation results show that the proposed control approach is effective.

  3. Current Mode Control for LLC Series Resonant DC-to-DC Converters

    Directory of Open Access Journals (Sweden)

    Jinhaeng Jang

    2015-06-01

    Full Text Available Conventional voltage mode control only offers limited performance for LLC series resonant DC-to-DC converters experiencing wide variations in operational conditions. When the existing voltage mode control is employed, the closed-loop performance of the converter is directly affected by unavoidable changes in power stage dynamics. Thus, a specific control design optimized at one particular operating point could become unacceptable when the operational condition is varied. This paper presents a new current mode control scheme which could consistently provide good closed-loop performance for LLC resonant converters for the entire operational range. The proposed control scheme employs an additional feedback from the current of the resonant tank network to overcome the limitation of the existing voltage mode control. The superiority of the proposed current mode control over the conventional voltage mode control is verified using an experimental 150 W LLC series resonant DC-to-DC converter.

  4. Realization of Electronically Controllable Current-mode Square-rooting Circuit Based on MO-CFTA

    OpenAIRE

    P. Silapan; C. Chanapromma; T. Worachak

    2011-01-01

    This article proposes a current-mode square-rooting circuit using current follower transconductance amplifier (CTFA). The amplitude of the output current can be electronically controlled via input bias current with wide input dynamic range. The proposed circuit consists of only single CFTA. Without any matching conditions and external passive elements, the circuit is then appropriate for an IC architecture. The magnitude of the output signal is temperature-insensitive. Th...

  5. Adaptive Hysteresis Band Current Control for Transformerless Single-Phase PV Inverters

    DEFF Research Database (Denmark)

    Vázquez, Gerardo; Rodriguez, Pedro; Ordoñez, Rafael

    2009-01-01

    Current control based on hysteresis algorithms are widely used in different applications, such as motion control, active filtering or active/reactive power delivery control in distributed generation systems. The hysteresis current control provides to the system a fast and robust dynamic response,...... different single-phase PV inverter topologies, by means of simulations performed with PSIM. In addition, the behavior of the thermal losses when using each control structure in such converters has been studied as well.......Current control based on hysteresis algorithms are widely used in different applications, such as motion control, active filtering or active/reactive power delivery control in distributed generation systems. The hysteresis current control provides to the system a fast and robust dynamic response......, and requires a simple implementation in standard digital signal platforms. On the other hand, the main drawback of classical hysteresis current control lies in the fact that the switching frequency is variable, as the hysteresis band is fixed. In this paper a variable band hysteresis control algorithm...

  6. Converter-flux-based current control of voltage source PWM rectifiers - analysis and implementation

    Energy Technology Data Exchange (ETDEWEB)

    Poellaenen, R.

    2003-07-01

    Pulsewidth-modulated (PWM) rectifier technology is increasingly used in industrial applications like variable-speed motor drives, since it offers several desired features such as sinusoidal input currents, controllable power factor, bidirectional power flow and high quality DC output voltage. To achieve these features, however, an effective control system with fast and accurate current and DC voltage responses is required. From various control strategies proposed to meet these control objectives, in most cases the commonly known principle of the synchronous-frame current vector control along with some space-vector PWM scheme have been applied. Recently, however, new control approaches analogous to the well-established direct torque control (DTC) method for electrical machines have also emerged to implement a high-performance PWM rectifier. In this thesis the concepts of classical synchronous-frame current control and DTC-based PWM rectifier control are combined and a new converter-flux-based current control (CFCC) scheme is introduced. To achieve sufficient dynamic performance and to ensure a stable operation, the proposed control system is thoroughly analysed and simple rules for the controller design are suggested. Special attention is paid to the estimation of the converter flux, which is the key element of converter-flux-based control. Discrete-time implementation is also discussed. Line-voltage-sensorless reactive reactive power control methods for the L- and LCL-type line filters are presented. For the L-filter an open-loop control law for the d-axis current reference is proposed. In the case of the LCL-filter the combined open-loop control and feedback control is proposed. The influence of the erroneous filter parameter estimates on the accuracy of the developed control schemes is also discussed. A new zero vector selection rule for suppressing the zero-sequence current in parallel-connected PWM rectifiers is proposed. With this method a truly standalone and

  7. A unified grid current control for grid-interactive DG inverters in microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittan...... locus analyses in the discrete z-domain are performed for elaborating the controller design. Simulations and experimental results demonstrate the performances of the proposed approach.......This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittance...... in the outer loop. It, therefore, provides several superior features over traditional control schemes: 1) high-quality grid current in the grid-connected mode, 2) inherent derivative-less virtual output impedance control, and 3) the unified active damping for both grid-connected and islanded operations. Root...

  8. Frequency Response Analysis of Current Controllers for Selective Harmonic Compensation in Active Power Filters

    DEFF Research Database (Denmark)

    Lascu, C.; Asiminoaei, L.; Boldea, I.

    2009-01-01

    This paper compares four current control structures for selective harmonic compensation in active power filters. All controllers under scrutiny perform the harmonic compensation by using arrays of resonant controllers, one for the fundamental and one for each harmonic of interest, in order to ach...

  9. Simple DCM or CRM analog peak current controller for HV capacitor charge-discharge applications

    DEFF Research Database (Denmark)

    Trintis, Ionut; Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a simple analog current controller suitable for buck and boost converter topologies. The controller operates in DCM or CRM, depending on the setup. The experimental results are presented to validate the proposed controller functionality for a high voltage capacitor charge...

  10. Design of laser diode driver with constant current and temperature control system

    Science.gov (United States)

    Wang, Ming-cai; Yang, Kai-yong; Wang, Zhi-guo; Fan, Zhen-fang

    2017-10-01

    A laser Diode (LD) driver with constant current and temperature control system is designed according to the LD working characteristics. We deeply researched the protection circuit and temperature control circuit based on thermos-electric cooler(TEC) cooling circuit and PID algorithm. The driver could realize constant current output and achieve stable temperature control of LD. Real-time feedback control method was adopted in the temperature control system to make LD work on its best temperature point. The output power variety and output wavelength shift of LD caused by current and temperature instability were decreased. Furthermore, the driving current and working temperature is adjustable according to specific requirements. The experiment result showed that the developed LD driver meets the characteristics of LD.

  11. Current commands for high-efficiency torque control of DC shunt motor

    OpenAIRE

    Funabiki, Shigeyuki; Fukushima, T.

    1991-01-01

    The current commands for a high-efficiency torque control of a DC shunt motor are described. In the proposed control method, the effect of a magnetic saturation and an armature reaction are taken into account by representing the coefficients of an electromotive force and a torque as a function of the field current, the armature current and the revolving speed. The current commands at which the loss of the motor drive system becomes a minimum are calculated as an optimal problem. The proposed ...

  12. Modeling and control of the output current of a Reformed Methanol Fuel Cell system

    DEFF Research Database (Denmark)

    Justesen, Kristian Kjær; Andreasen, Søren Juhl; Pasupathi, Sivakumar

    2015-01-01

    In this work, a dynamic Matlab SIMULINK model of the relationship between the fuel cell current set point of a Reformed Methanol Fuel Cell system and the output current of the system is developed. The model contains an estimated fuel cell model, based on a polarization curve and assumed first order...... dynamics, as well as a battery model based on an equivalent circuit model and a balance of plant power consumption model. The models are tuned with experimental data and verified using a verification data set. The model is used to develop an output current controller which can control the charge current...

  13. Performance assessment of a dynamic current allocator for the JET eXtreme Shape Controller

    International Nuclear Information System (INIS)

    Varano, G.; Ambrosino, G.; Tommasi, G.De; Galeani, S.; Pironti, A.; Zaccarian, L.

    2011-01-01

    This paper reports on a recently proposed dynamic allocation technique that can be effectively adopted to handle the current saturations of the Poloidal Field coils with the eXtreme Shape Controller. The proposed approach allows to automatically relax the plasma shape regulation when the reference shape requires current levels out of the available ranges, finding in real-time an optimal trade-off between shape control precision and currents saturation avoidance. In this paper the results attained during preliminary analysis are presented, showing the advantage arising from the use of the dynamic allocator, versus the bare use of the eXtreme Shape Controller.

  14. A novel harmonic current sharing control strategy for parallel-connected inverters

    DEFF Research Database (Denmark)

    Guan, Yajuan; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    A novel control strategy which enables proportional linear and nonlinear loads sharing among paralleled inverters and voltage harmonic suppression is proposed in this paper. The proposed method is based on the autonomous currents sharing controller (ACSC) instead of conventional power droop control......) is used to proportionally share current components at different sequences and orders independently among the paralleled inverters. Proportional resonance controllers tuned at selected frequencies are used to suppress voltage harmonics. Simulations based on two 2.2 kW paralleled three-phase inverters...... to provide fast transient response, decoupling control and large stability margin. The current components at different sequences and orders are decomposed by a multi-second-order generalized integrator-based frequency locked loop (MSOGI-FLL). A harmonic-orthogonal-virtual-resistances controller (HOVR...

  15. [An automatic torque control system for a bicycle ergometer equipped with an eddy current brake].

    Science.gov (United States)

    Kikinev, V V

    2007-01-01

    The main elements of the loading device of a bicycle ergometer, including an eddy current brake and a torque sensor, are described. The automatic torque control system, which includes the loading device, is equipped with a stabilizing feedback controller that optimally approximates the closed-loop transfer function of the target model. The reduced transfer function model of the controller is of the fourth order. A method featuring a modulation-demodulation loop is suggested for implementation of the control system.

  16. Predictive Current Control of Grid-tied Cascade H-bridge Inverter

    OpenAIRE

    Pástor, Marek; Dudrik, Jaroslav

    2013-01-01

    This paper presents a grid-tied cascade H-bridge inverter with predictive current control technique. The proposed 15-level cascade inverter consists of three H-bridge inverters with separated DC sources. At the output of the cascade inverter an L filter is used as a grid filter. The cascade inverter is controlled by the mean of RT-Lab. The predictive current regulator and one-phase synchronous reference frame PLL are designed with help of Rapid Control Prototyping. The proposed control method...

  17. A Hierarchical Control Scheme for Reactive Power and Harmonic Current Sharing in Islanded Microgrids

    DEFF Research Database (Denmark)

    Lorzadeh, Iman; Firoozabadi, Mehdi Savaghebi; Askarian Abyaneh, Hossein

    2015-01-01

    In this paper, a hierarchical control scheme consisting of primary and secondary levels is proposed for achieving accurate reactive power and harmonic currents sharing among interface inverters of distributed generators (DGs) in islanded microgrids. Firstly, fundamental and main harmonic componen...

  18. Control Strategies for Islanded Microgrid using Enhanced Hierarchical Control Structure with Multiple Current-Loop Damping Schemes

    DEFF Research Database (Denmark)

    Han, Yang; Shen, Pan; Zhao, Xin

    2017-01-01

    In this paper, the modeling, controller design, and stability analysis of the islanded microgrid (MG) using enhanced hierarchical control structure with multiple current loop damping schemes is proposed. The islanded MG is consisted of the parallel-connected voltage source inverters using LCL...

  19. Mitigation of Wind Power Fluctuation by Active Current Control of Variable Speed Wind Turbines

    DEFF Research Database (Denmark)

    Zhang, Yunqian; Chen, Zhe; Hu, Weihao

    2013-01-01

    converter in Simulink. A simple and effective method of wind power fluctuations mitigation by active current control of DFIG is proposed. It smoothes the generator output active power oscillations by adjusting the active current of the DFIG, such that the power oscillation is stored as the kinetic energy...

  20. Instantaneous Project Controls: Current Status, State of the Art, Benefits, and Strategies

    Science.gov (United States)

    Abbaszadegan, Amin

    2016-01-01

    Despite advancements in construction and construction-related technology, capital project performance deviations, typically overruns, remain endemic within the capital projects industry. Currently, management is generally unaware of the current status of their projects, and thus monitoring and control of projects are not achieved effectively. In…

  1. High performance predictive current control of a three phase VSI: An ...

    Indian Academy of Sciences (India)

    The effect of weighting factor on the switching frequency minimization and the current tracking error with delay compensation for the two level voltage source inverter (VSI) are investigated in this paper. The outcomes of the predictive current control using an optimized weighting factor which is calculated using branch and ...

  2. Double-Frame Current Control with a Multivariable PI Controller and Power Compensation for Weak Unbalanced Networks

    CERN Document Server

    Siemaszko, Daniel

    2015-06-15

    The handling of weak networks with asymmetric loads and disturbances im- plies the accurate handling of the second-harmonic component that appears in an unbalanced network. This paper proposes a classic vector control approach using a PI-based controller with superior decoupling capabilities for operation in weak networks with unbalanced phase voltages. A synchronization method for weak unbalanced networks is detailed, with dedicated dimensioning rules. The use of a double-frame controller allows a current symmetry or controlled imbalance to be forced for compensation of power oscillations by controlling the negative current sequence. This paper also serves as a useful reminder of the proper way to cancel the inherent coupling effect due to the transformation to the synchronous rotating reference frame, and of basic considerations of the relationship between switching frequency and control bandwidth.

  3. The Influence of Controller Parameters on the Quality of the Train Converter Current

    Directory of Open Access Journals (Sweden)

    M. Brenna

    2011-01-01

    Full Text Available This paper presents a stability analysis of train converters in order to evaluate how the controller parameters affect the absorbed current. The new dynamic model presented in this paper is capable of considering the time-variant nature of the system for the correct tuning of the feedback proportional-integral PI controller, applying a current controlled modulation technique never used in high-power traction converters. The reduction of the harmonic content of the current absorbed by a converter employed at the input stage onboard high-speed trains is really important, considering the interaction with the signaling system set up for traffic control. A computer model of the converter, considering both the power and the control structure, has also been implemented in order to deliver a validated tool for the developed theoretical analysis.

  4. Active harmonic filtering using current-controlled, grid-connected DG units with closed-loop power control

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    voltage detection are not necessary for the proposed harmonic compensation method. Moreover, a closed-loop power control scheme is employed to directly derive the fundamental current reference without using any phase-locked loops (PLL). The proposed power control scheme effectively eliminates the impacts...... of steady-state fundamental current tracking errors in the DG units. Thus, an accurate power control is realized even when the harmonic compensation functions are activated. In addition, this paper also briefly discusses the performance of the proposed method when DG unit is connected to a grid...

  5. Active power filter for medium voltage networks with predictive current control

    Energy Technology Data Exchange (ETDEWEB)

    Verne, Santiago A.; Valla, Maria I. [Laboratorio de Electronica Industrial, Control e Instrumentacion (LEICI), Facultad de Ingenieria, Universidad Nacional de La Plata and CONICET, La Plata (Argentina)

    2010-12-15

    A transformer less Shunt Active Power Filter (SAPF) for medium voltage distribution networks based on Multilevel Diode Clamped Inverter is presented in this paper. Converter current control is based on a Model Predictive strategy, which gives very fast current response. Also, the algorithm includes voltage balancing capability which is essential for proper converter operation. The presented current control algorithm is naturally applicable to converters with an arbitrary number of levels with reduced computational effort by virtue of the incorporation of switching restrictions which are necessary for reliable converter operation. The performance of the proposed algorithm is evaluated by means of computer simulations. (author)

  6. H∞ Current Damping Control of DFIG based Wind Farm for Sub-Synchronous Control Interaction Mitigation

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Yang, Rong

    2018-01-01

    This paper proposes an H∞ damping controller for the doubly-fed induction generator (DFIG) based wind farm (WF) to mitigate sub-synchronous control interactions (SSCI) with series capacitor compensated lines. A multi-input multi-output (MIMO) uncertain state-space model is developed to reflect...

  7. Start Up Current Control of Buck-Boost Convertor-Fed Serial DC Motor

    Directory of Open Access Journals (Sweden)

    Yusuf SÖNMEZ

    2009-02-01

    Full Text Available Generally, DC motors are given preference for industrial applications such as electric locomotives, cranes, goods lifts. Because of they have high starting moment; they initially start with high current. This high start-up current must be decreased since it may damage windings of the motor and increases power consumption. It could be controlled by an appropriate driver system and controller. The nature of fuzzy logic control has adaptive characteristics that can achieve robust response to a system with uncertainty, parameter variation, and load disturbance. In this paper, fuzzy logic based control of start-up current of a Buck-Boost Converter fed serial DC motor is examined through computer simulation. In order to see the advantages of fuzzy logic control, classical PI control has applied to the same motor, under same circumstances and has been compared. C++ Builder software has been used for the simulation. According to the simulation results, plainly, fuzzy logic control has stronger responses than classical PI control and uses lower current at starting moment.

  8. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  9. Plug-and-play control and consensus algorithms for current sharing in DC microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Meng, Lexuan; Guerrero, Josep M.

    2017-01-01

    In this paper, we propose a secondary consensus-based control layer for current sharing and voltage balancing in DC microGrids (mGs). Differently from existing approaches based on droop control, we assume decentralized Plug-and-Play (PnP) regulators at the primary level, as they provide voltage s...

  10. Study on Catastrophic Air Current Early-warning and Control System of Coalmines

    Directory of Open Access Journals (Sweden)

    L.F. Fang

    2016-02-01

    Full Text Available Catastrophic air current significantly influences the stability of ventilation system, and existing studies have not considered the flow characteristics of catastrophic air current when designing the control systems. To analyze the effects of different kinds of coalmine accidents on safety production, grey relation entropy theory was used to analyze the hazard assessment of coalmine accidents. Fluent software was employed to study the flow characteristics of catastrophic air current, and the catastrophic air current early-warning and control system of coalmine was researched according to the theoretical analysis and numerical simulation. The threat of fire accidents and roof accidents were larger than other accidents. The influence of temperature and CO volume fraction distribution of fire accidents to the tailwind side was larger than that of the weather side, and gradient decreased on the weather side. This system can effectively control the spread of fire and poisonous gas,

  11. A current controlled matrix converter for wind energy conversion systems based on permanent magnet synchronous generator

    Directory of Open Access Journals (Sweden)

    Naggar H. Saad

    2016-05-01

    Full Text Available The main challenges of wind energy conversion systems (WECS are to maximize the energy capture from the wind and injecting reactive power during the fault. This paper presents a current controlled matrix converter to interface Permanent Magnet Synchronous Generators (PMSG based WECS with the grid. To achieve fast dynamic response with reduced current ripples, a hysteresis current control is utilized. The proposed control system decouples the active and reactive components of the PMSG current to extract the maximum power from the wind at a given wind velocity and to inject reactive power to the grid. Reactive power injection during the fault satisfying the grid-codes requirement. The proposed WECS has been modeled and simulated using PSCAD/EMTDC software package.

  12. Controlling interfered area in interferential current stimulation by electrode-area patterning.

    Science.gov (United States)

    Bounyong, S; Adachi, S; Yoshimoto, T; Ota, T; Ozawa, J

    2016-08-01

    Interferential current therapy is a noninvasive therapy using simultaneously two or more medium-frequency currents passing through tissue. By controlling the interfered area of the current flows, selective stimulation is possible in target muscles, including deep muscles. However, controlling the interfered area or the intensity of the current precisely is still lacking. Using simulations based on a biological model of the thigh as well as electrical muscle stimulation (EMS) experiments, we investigated the influence of electrode area ratio in changing the interfered area of the currents. Simulation and experiments were conducted under the same conditions, whereby current signals were applied through electrodes placed on the quadriceps and hamstring with an electrode area ratio of either 1:1 or 3:1. A comparison of the simulation results showed that the interferential current density decreased near the larger area electrode but increased near the smaller area electrode. In addition, the EMS experiment also showed that the quadriceps were stimulated using electrodes in a 1:1 area ratio, and the hamstrings were stimulated using electrodes in a 3:1 area ratio. These results demonstrated the possibility of controlling the area application of interferential current through electrode area patterning.

  13. Thoracic radiotherapy and breath control: current prospects; Radiotherapie thoracique et controle de la respiration: perspectives actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R. [Institut Sainte-Catherine, 84 - Avignon (France)

    2002-11-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  14. A Current Sensorless MPPT Control Method for a Stand-Alone-Type PV Generation System

    Science.gov (United States)

    Itako, Kazutaka; Mori, Takeaki

    In this paper, a current sensorless MPPT control method for a stand-alone-type PV generation system is proposed. This control method offers advantages of the simplified hardware configuration and the low cost, by using only one sensor to measure the PV output voltage. In the application to stand-alone-type with a battery load, the experimental results show that the estimated values of PV output current are accurate, and the use of the proposed MPPT control increases the PV generated energy by 16.3% compared to the conventional system. Furthermore, it is clarified that the proposed method has extremely high UUF (Useful utilization factor) of 98.7%.

  15. Predictive current control with instantaneous reactive power minimization for a four-leg indirect matrix converter

    OpenAIRE

    Garcia, Cristian F.; Rivera, Marco E.; Rodriguez, Jose R.; Wheeler, Patrick; Pena, Ruben S.

    2017-01-01

    This paper presents the experimental valida¬tion of a predictive current control strategy with minimiza¬tion of the instantaneous reactive input power for a Four-Leg Indirect Matrix Converter (4Leg-IMC). The topology includes an input matrix converter stage, which provides the dc voltage for a four-leg voltage source converter (VSC) output stage. The VSC’s fourth leg provides a path for the zero sequence load current. The control technique is based on a finite control set model predictive con...

  16. Design of PR current control with selective harmonic compensators using Matlab

    Directory of Open Access Journals (Sweden)

    Daniel Zammit

    2017-12-01

    Full Text Available This paper presents a procedure to design a Proportional Resonant (PR current controller with additional PR selective harmonic compensators for Grid Connected Photovoltaic (PV Inverters. The design of the PR current control and the harmonic compensators will be carried out using Matlab. Testing was carried out on a 3 kW Grid-Connected PV Inverter which was designed and constructed for this research. Both simulation and experimental results will be presented. Keywords: Inverters, Proportional-resonant controllers, Harmonic compensation, Photovoltaic, Matlab, SISO design tool

  17. Rotor Current Control of DFIG for Improving Fault Ride - Through Using a Novel Sliding Mode Control Approach

    Science.gov (United States)

    Cai, Guowei; Liu, Cheng; Yang, Deyou

    2013-11-01

    The doubly fed induction generators (DFIG) have been recognized as the dominant technology used in wind power generation systems with the rapid development of wind power. However, continuous operation of DFIG may cause a serious wind turbine generators tripping accident, due to destructive over-current in the rotor winding which is caused by the power system fault or inefficient fault ride-through (FRT) strategy. A new rotor current control scheme in the rotor-side converter (RSC) ispresented to enhance FRT capacities of grid-connected DFIG. Due to the strongly nonlinear nature of DFIG and insensitive to DFIG parameter's variations, a novel sliding mode controller was designed. The controller combines extended state observer (ESO) with sliding model variable structure control theory. The simulation is carried out to verify the effectiveness of the proposed control approach under various types of grid disturbances. It is shown that the proposed controller provides enhanced transient features than the classic proportional-integral control. The proposed control method can effectively reduce over-current in the RSC, and the transient pulse value of electromagnetic torque is too large under power grid fault.

  18. A novel current mode controller for a static compensator utilizing Goertzel algorithm to mitigate voltage sags

    International Nuclear Information System (INIS)

    Najafi, E.; Yatim, A.H.M.

    2011-01-01

    Research highlights: → We proposed a new current control method for STATCOM. → The current control method maintains a fixed switching frequency. → It also produces fewer harmonics compared to conventional hysteresis method. → A new voltage dip (sag) detection method was used in STATCOM. → The control method can mitigate voltage sag in each phase separately. -- Abstract: Static compensator (STATCOM) has been widely proposed for power quality and network stability improvement. It is easily connected in parallel to the electric network and has many advantages for electrical grids. It can improve network stability; power factor, power transfer rating and can avoid some disturbances such as sags and swells. Most of STATCOM controllers are based on voltage controllers that are based on balanced d-q transform. However, they are not thorough solutions for network disturbances since in most cases single-phase disturbances occur in electrical networks that cannot be avoided by the conventional controllers. Voltage mode controllers are also not capable of responding fast enough to the changes expected of a network system. This paper proposes a new current mode controller to overcome the mentioned problem. The approach uses a fixed frequency current controller to maintain voltage levels in voltage sags (dips). This approach is also simple and can be easily implemented by digitally. It has superior performance over conventional methods in terms of harmonic reduction in STATCOM output current. Another important factor for STATCOM effectiveness in sag mitigation is its sag detection method. This paper also introduces a new sag detection method based on Goertzel algorithm which is both effective and simple for practical applications. The simulation results presented illustrate the superiority of the proposed controller and sag detection algorithm to be utilized in the STATCOM.

  19. Study on the Electronic Magnetic Field Oriented Control Based on D-axis Current

    Directory of Open Access Journals (Sweden)

    Hongyu Feng

    2014-07-01

    Full Text Available In order to improve the magnetic field orientation accuracy and system performance, the electronic field oriented control has been a hot research field of the induction motor speed control. Although the vector control of AC machines has many excellent properties, the researchers have been attempting to simplify the calculating steps and the structure of the control system to improve the accuracy of filed-oriented and the performance of AC machine drives. Based on the analysis of the conventional induction motor magnetic field oriented control, this paper puts forward a novel method of stator magnetic field orientation control. By analytical methods, the given current of d-axis can be calculated directly, and the stator flux can be controlled precisely. This method has a fast flux and torque response, and the control performance is unaffected by the rotor parameters.

  20. Bat algorithm optimized fuzzy PD based speed controller for brushless direct current motor

    Directory of Open Access Journals (Sweden)

    K. Premkumar

    2016-06-01

    Full Text Available In this paper, design of fuzzy proportional derivative controller and fuzzy proportional derivative integral controller for speed control of brushless direct current drive has been presented. Optimization of the above controllers design is carried out using nature inspired optimization algorithms such as particle swarm, cuckoo search, and bat algorithms. Time domain specifications such as overshoot, undershoot, settling time, recovery time, and steady state error and performance indices such as root mean squared error, integral of absolute error, integral of time multiplied absolute error and integral of squared error are measured and compared for the above controllers under different operating conditions such as varying set speed and load disturbance conditions. The precise investigation through simulation is performed using simulink toolbox. From the simulation test results, it is evident that bat optimized fuzzy proportional derivative controller has superior performance than the other controllers considered. Experimental test results have also been taken and analyzed for the optimal controller identified through simulation.

  1. Harmonic Mitigation Using a Polarized Ramp-time Current-Controlled Inverter

    Directory of Open Access Journals (Sweden)

    Lawrence J. Borle

    2010-12-01

    Full Text Available This paper describes the implementation of a shunt active power filter for a three-phase four-wire system to compensate for power quality problems generated by mixed non-linear loads, which are a combination of harmonic, reactive and unbalanced components. The filter is a three-phase current-controlled voltage source inverter (CC-VSI with a filter inductor at the AC output and a DC-bus capacitor. The CC-VSI is operated to directly control the grid current to be sinusoidal and in phase with the grid voltage without sensing the load currents. The switching is controlled using polarized ramp-time current control, which is based on the concept of zero average current error (ZACE with a fixed switching frequency. The laboratory experiment results indicate that the filter is able to mitigate predominantly the harmonics, as well as the reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical although the grid voltage contains harmonics.

  2. Scrape-off-layer current and EUV diagnostics and control on the HBT-EP tokamak

    Science.gov (United States)

    Levesque, J. P.; Mauel, M. E.; Bialek, J.; Navratil, G. A.; Delgado-Aparicio, L.; Hansen, C. J.

    2015-11-01

    Non-axisymmetric currents in the scrape-off-layer (SOL) and conducting structure of a tokamak can produce severe forces at high plasma performance, compromising the device's structural integrity. Diagnosing these currents during disruptions is important for extrapolating forces in future machines including ITER. Progress on designing components to measure and control SOL and vessel currents in the HBT-EP tokamak is presented. Movable tiles positioned around limiting surfaces will measure SOL and vessel currents during mode activity and disruptions. Biasable plates at divertor strike points will allow control of field-aligned SOL currents for kink mode control studies and will drive convection in the plasma edge. In-vessel Rogowski coils will measure currents in wall components with high spatial resolution. A planned EUV diagnostic upgrade is also presented. Four sets of 16 poloidal views will allow tomographic reconstruction of plasma emissivity and internal kink mode structure. A separate two-color, 16-chord tangential system will allow reconstruction of temperature profiles versus time. Measurements will be input to HBT-EP's GPU-based feedback system, providing active feedback for kink modes using only optical sensors and both magnetic and edge current actuators. Supported by U.S. DOE Grant DE-FG02-86ER53222.

  3. SOME CONSIDERATIONS OVER THE INTERNAL CONTROL IN THE CONTEXT OF CURRENT ACCOUNTANCY REGULATIONS

    Directory of Open Access Journals (Sweden)

    Lenghel Dorin Radu

    2012-12-01

    Full Text Available Through the hereby study we set ourselves on an analysis over the internal control and the ways of implementation of it. The final purpose of our research is represented by the characteristics of the internal control system in the context of current accountancy regulations. The accomplishment of such goal has forced us to research the current literature in the area and also the legal regulations over internal control. Of course, the accomplishment of such a research was possible only after a pertinent analysis over the opinions expressed in specialty literature regarding this area. Our research wants to be with a theoretical and applicative character. It is based on analysing the internal control system, the methodology of internal control and the steps of internal control. We express our belief that the implementation of the internal control in a very exact manner comes as an aid to the company management and lead to the accomplishment of managerial objectives and policies. In what it regards the result of our research there can be drawn the following conclusions: from the legal regulations (OMFP nr. 3055/2009, there is no clear conclusion over the procedures and policies of implementation of internal control applicable to an economical entity; also there are not presented in a detailed way the types (forms of internal control, being presented in the legal regulations only a classification of them after the time in which they are exercised (before, during or after the finishing of the operations; also in the legal regulations there is developed a certain way of internal control, represented by the financial and accounting internal control, as if the other forms of internal control do not exist; in what regards the components of internal control, these are presented in another way, but similar to already known models of internal control (Coso and Coco; also in the legal regulations there are presented the general objectives of internal control

  4. Two-group Current-equivalent Parameters for Control Rod Cells. Autocode Programme CRCC

    Energy Technology Data Exchange (ETDEWEB)

    Norinder, O.; Nyman, K.

    1962-06-15

    In two-group neutron diffusion calculations there is mostly necessary to describe the influence of control rods by equivalent homogeneous two-group parameters in regions about the control rods. The problem is solved for a control rod in a medium characterized by two-group parameters. The property of fast and thermal neutr. on current equivalence is selected to obtain equivalent two-group parameters for a homogeneous cell with the same radius as the control rod cell. For the parameters determined one obtains the same fast and thermal neutron current into the rod cell and the equivalent cell independent of the fast and thermal flux amplitudes on the cell boundaries. The equivalent parameters are obtained as a solution of a system of transcendental equations. A Ferranti Mercury Autocode performing the solution is described. Calculated equivalent parameters for control rods in a heavy water lattice are given for some representative cases.

  5. High-frequency, three-phase current controller implementation in an FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M.; Round, S. D.; Kolar, J. W.

    2008-07-01

    Three phase rectifiers with switching frequencies of 500 kHz or more require high speed current controllers. At such high switching frequencies analog controllers as well as high speed digital signal processing (DSP) systems have limited performance. In this paper, two high speed current controller implementations using two different field-programmable gate arrays (FPGA) - one for switching frequencies up to 1 MHz and one for switching frequencies beyond 1 MHz - are presented to overcome this performance limitation. Starting with the digital system design all the blocks of the signal chain, containing analog-to-digital (A/D) interface, digital controller implementation using HW-multipliers and implementation of a novel high speed, high resolution pulse width modulation (PWM) are discussed and compared. Final measurements verify the performance of the controllers. (author)

  6. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control...

  7. Intensity and frequency stabilization of a laser diode by simultaneously controlling its temperature and current

    Science.gov (United States)

    Mu, Weiwei; Hu, Zhaohui; Wang, Jing; Zhou, Binquan

    2017-10-01

    Nuclear magnetic resonance gyroscope (NMRG) detects the angular velocity of the vehicle utilizing the interaction between the laser beam and the alkali metal atoms along with the noble gas atoms in the alkali vapor cell. In order to reach high precision inertial measurement target, semiconductor laser in NMRG should have good intensity and frequency stability. Generally, laser intensity and frequency are stabilized separately. In this paper, a new method to stabilize laser intensity and frequency simultaneously with double-loop feedback control is presented. Laser intensity is stabilized to the setpoint value by feedback control of laser diode's temperature. Laser frequency is stabilized to the Doppler absorption peak by feedback control of laser diode's current. The feedback control of current is a quick loop, hence the laser frequency stabilize quickly. The feedback control of temperature is a slow loop, hence the laser intensity stabilize slowly. With the feedback control of current and temperature, the laser intensity and frequency are stabilized finally. Additionally, the dependence of laser intensity and frequency on laser diode's current and temperature are analyzed, which contributes to choose suitable operating range for the laser diode. The advantage of our method is that the alkali vapor cell used for stabilizing laser frequency is the same one as the cell used for NMRG to operate, which helps to miniaturize the size of NMRG prototype. In an 8-hour continuous measurement, the long-term stability of laser intensity and frequency increased by two orders of magnitude and one order of magnitude respectively.

  8. Control of the Superconducting Magnets current Power Supplies of the TJ-II Gyrotrons

    International Nuclear Information System (INIS)

    Ros, A.; Fernandez, A.; Tolkachev, A.; Catalan, G.

    2006-01-01

    The TJ-II ECRH heating system consists of two gyrotrons, which can deliver a maximum power of 300 kW at a frequency of 53.2 GHz. Another 28 GHz gyrotron is going to be used in the Bernstein waves heating system. In order to get the required frequency, the gyrotrons need and homogeneous magnetic field of several tesla, which is generated by a superconducting coil field by a current source. This document describes the current source control as well as the high precision ammeters control. These ammeters measure the current in the superconducting coils. The user interface and the programming of the control system are described. The communication between devices is also explained. (author) 9 Refs

  9. A sensorless control method for capacitor voltage balance and circulating current suppression of modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    . As a result, a sensorless control method is proposed in this paper, which targets to improve the performances of MMC in respect to the above mentioned disadvantages: To decrease the cost and simplify the physical implementation, a state observer is proposed and designed to estimate both the capacitor voltages......There are several problems in the Modular Multilevel Converter (MMC), such as the appearance of circulating current, capacitor voltage unbalance and the requirement for a high number of sensors. All these problems will decrease the reliability and raise the cost/uncertainty of using MMC solutions...... and the circulating currents in order to replace the high numbers of sensors. Furthermore, a control method combining the circulating current suppression and the capacitor voltage balancing is conducted based on the proposed state observer. It is concluded that the proposed state observer and control method can...

  10. Self-controllable Voltage Level Technique to reduce leakage current in DRAM 4×4

    OpenAIRE

    Radha.K; M. Sowmyasri

    2016-01-01

    As the technology improved to support very large chip sizes, system designers were faced with power consumption problem and leakage current problem. CMOS technology has increased in level of importance to the point where it now clearly holds center stage as the dominant VLSI technology The present work shows the implementation of a DRAM 4×4 (dynamic random access memory) with self controllable voltage level (SVL) technique. SVL technique is leakage current reduction technique. Sim...

  11. Sawtooth control by on-axis electron cyclotron current drive on the WT-3 tokamak

    International Nuclear Information System (INIS)

    Asakawa, M.; Tanabe, K.; Nakayama, A.; Watanabe, M.; Nakamura, M.; Tanaka, H.; Maekawa, T.; Terumichi, Y.

    1999-01-01

    The experiments on control of sawtooth oscillations (STO) by electron cyclotron current drive (ECCD) have been performed on the WT-3 tokamak. Stabilization and excitation of STO are observed for counter-ECCD and co-ECCD, respectively, when the position of the power deposition is located inside the inversion radius. These results are due to the modification of the current profile near the magnetic axis. (author)

  12. Sawtooth control by on-axis electron cyclotron current drive on the WT-3 tokamak

    International Nuclear Information System (INIS)

    Asakawa, M.; Tanabe, K.; Nakayama, A.; Watanabe, M.; Nakamura, M.; Tanaka, H.; Maekawa, T.; Terumichi, Y.

    2001-01-01

    The experiments on control of sawtooth oscillations (STO) by electron cyclotron current drive (ECCD) have been performed on the WT-3 tokamak. Stabilization and excitation of STO are observed for counter-ECCD and co-ECCD, respectively, when the position of the power deposition is located inside the inversion radius. These results are due to the modification of the current profile near the magnetic axis. (author)

  13. MHD-mode locking by controlled halo-current in the T-10 tokamak

    International Nuclear Information System (INIS)

    Ivanov, N.V.; Chudnovskiy, A.N.; Gvozdkov, Yu.V.; Kakurin, A.M.; Orlovskiy, I.I.; Pavlov, Yu.D.; Piterskiy, V.V.; Safonova, M.B.; Volkov, V.V.

    2003-01-01

    Experiments on a non-disruptive halo-current influence on the m = 2 mode behaviour at the flat-top stage of a tokamak discharge are presented. The halo-current in the Rail Limiter - Plasma - Vacuum Vessel - External Circuit - Rail Limiter loop was used. An EMF source controlled with a pre-programmed signal or with a feedback m = 2 signal was introduced into the external part of the halo-current circuit. The EMF source generated oscillating halo-currents with up to 500 A amplitude in the frequency range 0-20 kHz. In the case of the pre-programmed control signal the switching on of the EMF source resulted in the shift of the m = 2 mode frequency to the frequency of the halo-current oscillations. In particular, the rotation of the m = 2 mode stopped under a pulse of zero-frequency halo-current. In the tokamak discharges when the mode rotation stopped by itself before the switching on of the oscillating halo-current, the mode rotation was restored at the halo-current frequency. In the case of the halo-current feedback control by the m = 2 mode signal, the effect depended on the choice of the phase shift in the feedback loop. Some increase or decrease of the m = 2 mode amplitude as well as some variations of the mode frequency were observed at different values of the phase shift. The halo-current effect on the m = 2 mode behaviour can be attributed to a coupling between the m/n = 2/1 magnetic islands and the halo-current magnetic field. The experiment was simulated on the assumption that the tearing mode is affected by the halo-current magnetic field helical component with the same space structure. The equation for the disturbed poloidal flux in the presence of the external helical surface current was used for the analysis. In the calculations for the T-10 conditions, the mode behaviour under the effect of the halo-current was similar to the experimental observations. (author)

  14. Electric control of emergent magnonic spin current and dynamic multiferroicity in magnetic insulators at finite temperatures

    Science.gov (United States)

    Wang, Xi-guang; Chotorlishvili, L.; Guo, Guang-hua; Berakdar, J.

    2018-04-01

    Conversion of thermal energy into magnonic spin currents and/or effective electric polarization promises new device functionalities. A versatile approach is presented here for generating and controlling open circuit magnonic spin currents and an effective multiferroicity at a uniform temperature with the aid of spatially inhomogeneous, external, static electric fields. This field applied to a ferromagnetic insulator with a Dzyaloshinskii-Moriya type coupling changes locally the magnon dispersion and modifies the density of thermally excited magnons in a region of the scale of the field inhomogeneity. The resulting gradient in the magnon density can be viewed as a gradient in the effective magnon temperature. This effective thermal gradient together with local magnon dispersion result in an open-circuit, electric field controlled magnonic spin current. In fact, for a moderate variation in the external electric field the predicted magnonic spin current is on the scale of the spin (Seebeck) current generated by a comparable external temperature gradient. Analytical methods supported by full-fledge numerics confirm that both, a finite temperature and an inhomogeneous electric field are necessary for this emergent non-equilibrium phenomena. The proposal can be integrated in magnonic and multiferroic circuits, for instance to convert heat into electrically controlled pure spin current using for example nanopatterning, without the need to generate large thermal gradients on the nanoscale.

  15. Current harmonics elimination control method for six-phase PM synchronous motor drives.

    Science.gov (United States)

    Yuan, Lei; Chen, Ming-liang; Shen, Jian-qing; Xiao, Fei

    2015-11-01

    To reduce the undesired 5th and 7th stator harmonic current in the six-phase permanent magnet synchronous motor (PMSM), an improved vector control algorithm was proposed based on vector space decomposition (VSD) transformation method, which can control the fundamental and harmonic subspace separately. To improve the traditional VSD technology, a novel synchronous rotating coordinate transformation matrix was presented in this paper, and only using the traditional PI controller in d-q subspace can meet the non-static difference adjustment, the controller parameter design method is given by employing internal model principle. Moreover, the current PI controller parallel with resonant controller is employed in x-y subspace to realize the specific 5th and 7th harmonic component compensation. In addition, a new six-phase SVPWM algorithm based on VSD transformation theory is also proposed. Simulation and experimental results verify the effectiveness of current decoupling vector controller. Copyright © 2015 ISA. Published by Elsevier Ltd. All rights reserved.

  16. Distributed Cooperative Current-Sharing Control of Parallel Chargers Using Feedback Linearization

    Directory of Open Access Journals (Sweden)

    Jiangang Liu

    2014-01-01

    Full Text Available We propose a distributed current-sharing scheme to address the output current imbalance problem for the parallel chargers in the energy storage type light rail vehicle system. By treating the parallel chargers as a group of agents with output information sharing through communication network, the current-sharing control problem is recast as the consensus tracking problem of multiagents. To facilitate the design, input-output feedback linearization is first applied to transform the nonidentical nonlinear charging system model into the first-order integrator. Then, a general saturation function is introduced to design the cooperative current-sharing control law which can guarantee the boundedness of the proposed control. The cooperative stability of the closed-loop system under fixed and dynamic communication topologies is rigorously proved with the aid of Lyapunov function and LaSalle invariant principle. Simulation using a multicharging test system further illustrates that the output currents of parallel chargers are balanced using the proposed control.

  17. Current control loop design and analysis based on resonant regulators for microgrid applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michelle; de Sousa Ribeiro, Luiz Antonio

    2015-01-01

    Voltage and current control loops play an important role in the performance of microgrids employing power electronics voltage source inverters. Correct design of feedback loops is essential for the proper operation of these systems. This paper analyzes the influence of state feedback cross......-coupling in the design of resonant regulators for inner current loops in power converters operating in standalone microgrids. It is also demonstrated that the effect of state feedback cross-coupling degrades the performance of the control loops by increasing the steady-state error. Different resonant regulators...

  18. Eddy-current inspection of high flux isotope reactor nuclear control rods

    International Nuclear Information System (INIS)

    Smith, J.H.; Chitwood, L.D.

    1981-07-01

    Inner control rods for the High Flux Isotope Reactor were nondestructively inspected for defects by eddy-current techniques. During these examinations aluminum cladding thickness and oxide thickness on the cladding were also measured. Special application techniques were required because of the high-radiation levels (approx. 10 5 R/h at 30 cm) present and the relatively large temperature gradients that occurred on the surface of the control rods. The techniques used to perform the eddy-current inspections and the methods used to reduce the associated data are described

  19. Compensation methods applied in current control schemes for large AC drive systems

    DEFF Research Database (Denmark)

    Rus, D. C.; Preda, N. S.; Teodorescu, Remus

    2012-01-01

    The paper deals with modified PI current control structures for large AC drive systems which use surface mounted permanent magnet synchronous machines or squirrel-cage induction motors supplied with voltage source inverters. In order to reduce the power losses caused by high frequency switching...... of the semiconductor devices, various compensation methods are used and a modified structure for a PI current controller is proposed, to reduce the switching frequency of the inverter for the same operating frequency of the drive. Simulation, experimental development and test results are presented in order...

  20. Two-dimensional effects in the problem of tearing modes control by electron cyclotron current drive

    International Nuclear Information System (INIS)

    Comisso, L.; Lazzaro, E.

    2010-01-01

    The design of means to counteract robustly the classical and neoclassical tearing modes in a tokamak by localized injection of an external control current requires an ever growing understanding of the physical process, beyond the Rutherford-type zero-dimensional models. Here a set of extended magnetohydrodynamic nonlinear equations for four continuum fields is used to investigate the two-dimensional effects in the response of the reconnecting modes to specific inputs of the localized external current. New information is gained on the space- and time-dependent effects of the external action on the two-dimensional structure of magnetic islands, which is very important to formulate applicable control strategies.

  1. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming

    2016-01-01

    This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...... distortions considered include asymmetric voltage dips and grid background harmonics. An uncertain DFIG model is developed with uncertain factors originating from distorted stator voltage, and changed generator parameters due to the flux saturation effect, the skin effect, etc. Weighting functions...... with a 1.5 MW DFIG model, showing its harmonics suppression ability with DFIG parameter perturbation and improved robustness....

  2. Theory and experiments on RF plasma heating, current drive and profile control in TORE SUPRA

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, D.

    1994-01-01

    This paper reviews the main experimental and theoretical achievements related to the study of RF heating and non-inductive current drive and particularly phenomena related to the current density profile control and the potentiality of producing stationary enhanced performance regimes: description of the Lower Hybrid (LH) and Ion Cyclotron Resonant Frequency (ICRF) systems; long pulse coupling performance of the RF systems; observation of the transition to the so-called ``stationary LHEP regime`` in which the (flat) central current density and (peaked) electron temperature profiles are fully decoupled; experiments on ICRF sawtooth stabilization with the combined effect of LHCD modifying the current density profile; diffusion of fast electrons generated by LH waves; ramp-up experiments in which the LH power provided a significant part of the resistive poloidal flux and flux consumption scaling; theory of spectral wave diffusion and multipass absorption; fast wave current drive modelling with the Alcyon full wave code; a reflector LH antenna concept. 18 figs., 48 refs.

  3. Theory and experiments on RF plasma heating, current drive and profile control in TORE SUPRA

    International Nuclear Information System (INIS)

    Moreau, D.

    1994-01-01

    This paper reviews the main experimental and theoretical achievements related to the study of RF heating and non-inductive current drive and particularly phenomena related to the current density profile control and the potentiality of producing stationary enhanced performance regimes: description of the Lower Hybrid (LH) and Ion Cyclotron Resonant Frequency (ICRF) systems; long pulse coupling performance of the RF systems; observation of the transition to the so-called ''stationary LHEP regime'' in which the (flat) central current density and (peaked) electron temperature profiles are fully decoupled; experiments on ICRF sawtooth stabilization with the combined effect of LHCD modifying the current density profile; diffusion of fast electrons generated by LH waves; ramp-up experiments in which the LH power provided a significant part of the resistive poloidal flux and flux consumption scaling; theory of spectral wave diffusion and multipass absorption; fast wave current drive modelling with the Alcyon full wave code; a reflector LH antenna concept. 18 figs., 48 refs

  4. MISO Current-mode Biquad Filter with Independent Control of Pole Frequency and Quality Factor

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-09-01

    Full Text Available This article presents a three-inputs single-output biquadratic filter performing completely standard functions: low-pass, high-pass, band-pass, band-reject and all-pass functions, based on current controlled current conveyor transconductance amplifier (CCCCTA. The quality factor and pole frequency can be electronically/independently tuned via the input bias current. The proposed circuit uses 2 CCCCTAs and 2 grounded capacitors without external any resistors which is very suitable to further develop into an integrated circuit. The filter does not require double input current signal. Each function response can be selected by suitably selecting input signals with digital method. Moreover, the circuit possesses high output impedance which would be an ideal choice for current-mode cascading. The PSPICE simulation results are included to verify the workability of the proposed filter. The given results agree well with the theoretical anticipation.

  5. Design and Implementation of Digital Current Mode Controller for DC-DC Converters

    DEFF Research Database (Denmark)

    Taeed, Fazel

    In the recent decades, shortage of fossil fuels and global warming have increased the demand for renewable energy resources. Dc-dc converters are widely used in renewable energy systems, electric vehicles, and battery chargers. In practical applications, dc-dc converters are required to be regula......In the recent decades, shortage of fossil fuels and global warming have increased the demand for renewable energy resources. Dc-dc converters are widely used in renewable energy systems, electric vehicles, and battery chargers. In practical applications, dc-dc converters are required...... to be regulated by a closed-loop controller. The Peak Current Mode Control (PCMC) is one of the most promising control methods for dc-dc converters. It has been known for high bandwidth (speed), and inherent current protection. Increasing the controller bandwidth decreases the output filter size and cost. Analog...... controllers (including PCMC) are sensitive to temperature drift, component aging and noise. Digital controllers do not have the aforementioned drawbacks of analog controllers; but they have lower bandwidth than analog controllers due to the sampling and calculation delays. Generally, analog controllers have...

  6. Multi-Objective Predictive Balancing Control of Battery Packs Based on Predictive Current

    Directory of Open Access Journals (Sweden)

    Wenbiao Li

    2016-04-01

    Full Text Available Various balancing topology and control methods have been proposed for the inconsistency problem of battery packs. However, these strategies only focus on a single objective, ignore the mutual interaction among various factors and are only based on the external performance of the battery pack inconsistency, such as voltage balancing and state of charge (SOC balancing. To solve these problems, multi-objective predictive balancing control (MOPBC based on predictive current is proposed in this paper, namely, in the driving process of an electric vehicle, using predictive control to predict the battery pack output current the next time. Based on this information, the impact of the battery pack temperature caused by the output current can be obtained. Then, the influence is added to the battery pack balancing control, which makes the present degradation, temperature, and SOC imbalance achieve balance automatically due to the change of the output current the next moment. According to MOPBC, the simulation model of the balancing circuit is built with four cells in Matlab/Simulink. The simulation results show that MOPBC is not only better than the other traditional balancing control strategies but also reduces the energy loss in the balancing process.

  7. A GPS-Based Control Framework for Accurate Current Sharing and Power Quality Improvement in Microgrids

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad; Savaghebi, Mehdi; Lu, Dylan

    2017-01-01

    This paper proposes a novel hierarchical control strategy for improvement of load sharing and power quality in ac microgrids. This control framework is composed of a droop based controller at the primary level, and a combination of distributed power sharing and voltage conditioning schemes...... consensus protocol to ensure proportional sharing of average power. The voltage conditioning scheme produces compensation signals at fundamental and dominant harmonics to improve the voltage quality at a sensitive load bus. Experimental results are presented to validate the efficacy of the proposed method....... dynamic response. The droop coefficient, which acts as a virtual resistance is adaptively changed as a function of the peak current. This strategy not only simplifies the control design but also improves the current sharing accuracy at high loading conditions. The distributed power sharing scheme uses...

  8. Dynamic Control of the Vortex Pinning Potential in a Superconductor Using Current Injection through Nanoscale Patterns.

    Science.gov (United States)

    Kalcheim, Yoav; Katzir, Eran; Zeides, Felix; Katz, Nadav; Paltiel, Yossi; Millo, Oded

    2017-05-10

    Control over the vortex potential at the nanoscale in a superconductor is a subject of great interest for both fundamental and technological reasons. Many methods for achieving artificial pinning centers have been demonstrated, for example, with magnetic nanostructures or engineered imperfections, yielding many intriguing effects. However, these pinning mechanisms do not offer dynamic control over the strength of the patterned vortex potential because they involve static nanostructures created in or near the superconductor. Dynamic control has been achieved with scanning probe methods on the single vortex level but these are difficult so scale up. Here, we show that by applying controllable nanopatterned current injection, the superconductor can be locally driven out of equilibrium, creating an artificial vortex potential that can be tuned by the magnitude of the injected current, yielding a unique vortex channeling effect.

  9. The Current Status of Baculovirus and Their Implication for Insect Pest Control

    Directory of Open Access Journals (Sweden)

    Arman Wijonarko

    2001-07-01

    Full Text Available Baculovirus have been promoted as the promising bioinsecticides for their pest control potential for more than half a century. But only a few have been successful as biological control agent, and almost none has been proven as commercial success, or widely used for large-scale insect pest control. The bioinsecticides currently represent only a small fraction of the world pesticide market. The successful of the Bt crop marked a special achievement in the bioinsecticide market growth. How about the baculoviruses? The main hurdle for baculovirus to be developed as bioinsecticide is its poor performance compare to synthetic chemical ones, include the speed of kill, and host range. It is important to understand the nature of baculovirus, and explore the possibilities to develop new way in applying the baculovirus as bioinsecticides. Key words: current status, baculovirus, insect control

  10. Path Following Control of an AUV under the Current Using the SVR-ADRC

    Directory of Open Access Journals (Sweden)

    Zheping Yan

    2014-01-01

    Full Text Available A novel active disturbance rejection control (ADRC controller is proposed based on support vector regression (SVR. The SVR-ADRC is designed to force an underactuated autonomous underwater vehicle (AUV to follow a path in the horizontal plane with the ocean current disturbance. It is derived using SVR algorithm to adjust the coefficients of the nonlinear state error feedback (ELSEF part in ADRC to deal with nonlinear variations at different operating points. The trend of change about ELSEF coefficients in the simulation proves that the designed SVR algorithm maintains the characteristics of astringency and stability. Furthermore, the path following errors under current in simulation has proved the high accuracy, strong robustness, and stability of the proposed SVR-ADRC. The contributions of the proposed controller are to improve the characteristics of ADRC considering the changing parameters in operating environment which make the controller more adaptive for the situation.

  11. Station-keeping control of an unmanned surface vehicle exposed to current and wind disturbances

    OpenAIRE

    Sarda, Edoardo I.; Qu, Huajin; Bertaska, Ivan R.; von Ellenrieder, Karl D.

    2017-01-01

    Field trials of a 4 meter long, 180 kilogram, unmanned surface vehicle (USV) have been conducted to evaluate the performance of station-keeping heading and position controllers in an outdoor marine environment disturbed by wind and current. The USV has a twin hull configuration and a custom-designed propulsion system, which consists of two azimuthing thrusters, one for each hull. Nonlinear proportional derivative, backstepping and sliding mode feedback controllers were tested in winds of abou...

  12. Controlling fluctuations and transport in the reversed field pinch with edge current drive and plasma biasing

    International Nuclear Information System (INIS)

    Craig, D.J.G.

    1998-09-01

    Two techniques are employed in the Madison Symmetric Torus (MST) to test and control different aspects of fluctuation induced transport in the Reversed Field Pinch (RFP). Auxiliary edge currents are driven along the magnetic field to modify magnetic fluctuations, and the particle and energy transport associated with them. In addition, strong edge flows are produced by plasma biasing. Their effect on electrostatic fluctuations and the associated particle losses is studied. Both techniques are accomplished using miniature insertable plasma sources that are biased negatively to inject electrons. This type of emissive electrode is shown to reliably produce intense, directional current without significant contamination by impurities. The two most important conclusions derived from these studies are that the collective modes resonant at the reversal surface play a role in global plasma confinement, and that these modes can be controlled by modifying the parallel current profile outside of the reversal surface. This confirms predictions based on magnetohydrodynamic (MHD) simulations that auxiliary current drive in the sense to flatten the parallel current profile can be successful in controlling magnetic fluctuations in the RFP. However, these studies expand the group of magnetic modes believed to cause transport in MST and suggest that current profile control efforts need to address both the core resonant magnetic modes and those resonant at the reversal surface. The core resonant modes are not significantly altered in these experiments; however, the distribution and/or amplitude of the injected current is probably not optimal for affecting these modes. Plasma biasing generates strong edge flows with shear and particle confinement likely improves in these discharges. These experiments resemble biased H modes in other magnetic configurations in many ways. The similarities are likely due to the common role of electrostatic fluctuations in edge transport

  13. Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Gaubert, Jean-Paul; Krim, Fateh

    2010-01-01

    This paper is concerned with the design and implementation of current control of three-phase PWM rectifier based on predictive control strategy. The proposed predictive current control technique operates with constant switching frequency, using space-vector modulation (SVM). The main goal of the designed current control scheme is to maintain the dc-bus voltage at the required level and to achieve the unity power factor (UPF) operation of the converter. For this purpose, two predictive current control algorithms, in the sense of deadbeat control, are developed for direct controlling input current vector of the converter in the stationary α-β and rotating d-q reference frame, respectively. For both predictive current control algorithms, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of both tracking errors of current vector components at the end of the switching period, is computed and applied during a predefined switching period by means of SVM. The main advantages of the proposed predictive current control are that no need to use hysteresis comparators or PI controllers in current control loops, and constant switching frequency. Finally, the developed predictive current control algorithms were tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance in steady and transient states, and verify the validity of the proposed predictive current control which is compared to other control strategies.

  14. Control of trachoma in Australia: a model based evaluation of current interventions.

    Directory of Open Access Journals (Sweden)

    Andrew J Shattock

    2015-04-01

    Full Text Available Australia is the only high-income country in which endemic trachoma persists. In response, the Australian Government has recently invested heavily towards the nationwide control of the disease.A novel simulation model was developed to reflect the trachoma epidemic in Australian Aboriginal communities. The model, which incorporates demographic, migration, mixing, and biological heterogeneities, was used to evaluate recent intervention measures against counterfactual past scenarios, and also to assess the potential impact of a series of hypothesized future intervention measures relative to the current national strategy and intensity. The model simulations indicate that, under the current intervention strategy and intensity, the likelihood of controlling trachoma to less than 5% prevalence among 5-9 year-old children in hyperendemic communities by 2020 is 31% (19%-43%. By shifting intervention priorities such that large increases in the facial cleanliness of children are observed, this likelihood of controlling trachoma in hyperendemic communities is increased to 64% (53%-76%. The most effective intervention strategy incorporated large-scale antibiotic distribution programs whilst attaining ambitious yet feasible screening, treatment, facial cleanliness and housing construction targets. Accordingly, the estimated likelihood of controlling trachoma in these communities is increased to 86% (76%-95%.Maintaining the current intervention strategy and intensity is unlikely to be sufficient to control trachoma across Australia by 2020. However, by shifting the intervention strategy and increasing intensity, the likelihood of controlling trachoma nationwide can be significantly increased.

  15. Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind-Hydro Hybrid System

    Science.gov (United States)

    Ram Prabhakar, J.; Ragavan, K.

    2013-07-01

    This article proposes new power management based current control strategy for integrated wind-solar-hydro system equipped with battery storage mechanism. In this control technique, an indirect estimation of load current is done, through energy balance model, DC-link voltage control and droop control. This system features simpler energy management strategy and necessitates few power electronic converters, thereby minimizing the cost of the system. The generation-demand (G-D) management diagram is formulated based on the stochastic weather conditions and demand, which would likely moderate the gap between both. The features of management strategy deploying energy balance model include (1) regulating DC-link voltage within specified tolerances, (2) isolated operation without relying on external electric power transmission network, (3) indirect current control of hydro turbine driven induction generator and (4) seamless transition between grid-connected and off-grid operation modes. Furthermore, structuring of the hybrid system with appropriate selection of control variables enables power sharing among each energy conversion systems and battery storage mechanism. By addressing these intricacies, it is viable to regulate the frequency and voltage of the remote network at load end. The performance of the proposed composite scheme is demonstrated through time-domain simulation in MATLAB/Simulink environment.

  16. Control of trachoma in Australia: a model based evaluation of current interventions.

    Science.gov (United States)

    Shattock, Andrew J; Gambhir, Manoj; Taylor, Hugh R; Cowling, Carleigh S; Kaldor, John M; Wilson, David P

    2015-04-01

    Australia is the only high-income country in which endemic trachoma persists. In response, the Australian Government has recently invested heavily towards the nationwide control of the disease. A novel simulation model was developed to reflect the trachoma epidemic in Australian Aboriginal communities. The model, which incorporates demographic, migration, mixing, and biological heterogeneities, was used to evaluate recent intervention measures against counterfactual past scenarios, and also to assess the potential impact of a series of hypothesized future intervention measures relative to the current national strategy and intensity. The model simulations indicate that, under the current intervention strategy and intensity, the likelihood of controlling trachoma to less than 5% prevalence among 5-9 year-old children in hyperendemic communities by 2020 is 31% (19%-43%). By shifting intervention priorities such that large increases in the facial cleanliness of children are observed, this likelihood of controlling trachoma in hyperendemic communities is increased to 64% (53%-76%). The most effective intervention strategy incorporated large-scale antibiotic distribution programs whilst attaining ambitious yet feasible screening, treatment, facial cleanliness and housing construction targets. Accordingly, the estimated likelihood of controlling trachoma in these communities is increased to 86% (76%-95%). Maintaining the current intervention strategy and intensity is unlikely to be sufficient to control trachoma across Australia by 2020. However, by shifting the intervention strategy and increasing intensity, the likelihood of controlling trachoma nationwide can be significantly increased.

  17. A DC Microgrid Coordinated Control Strategy Based on Integrator Current-Sharing

    DEFF Research Database (Denmark)

    Gao, Liyuan; Liu, Yao; Ren, Huisong

    2017-01-01

    The DC microgrid has become a new trend for microgrid study with the advantages of high reliability, simple control and low losses. With regard to the drawbacks of the traditional droop control strategies, an improved DC droop control strategy based on integrator current-sharing is introduced......, at the system coordinated control level, a hierarchical/droop control strategy based on the DC bus voltage is proposed. In the strategy, the operation modes of the AC main network and micro-sources are determined through detecting the DC voltage variation, which can ensure the power balance of the DC microgrid...... under different operating conditions. Meanwhile, communication is not needed between different DG units, while each DG unit needs to sample the DC bus voltage, which retains the plug-and-play feature of the DC microgrid. The proposed control strategy is validated by simulation on a DC microgrid...

  18. Parameter Improved Particle Swarm Optimization Based Direct-Current Vector Control Strategy for Solar PV System

    Directory of Open Access Journals (Sweden)

    NAMMALVAR, P.

    2018-02-01

    Full Text Available This paper projects Parameter Improved Particle Swarm Optimization (PIPSO based direct current vector control technology for the integration of photovoltaic array in an AC micro-grid to enhance the system performance and stability. A photovoltaic system incorporated with AC micro-grid is taken as the pursuit of research study. The test system features two power converters namely, PV side converter which consists of DC-DC boost converter with Perturbation and Observe (P&O MPPT control to reap most extreme power from the PV array, and grid side converter which consists of Grid Side-Voltage Source Converter (GS-VSC with proposed direct current vector control strategy. The gain of the proposed controller is chosen from a set of three values obtained using apriori test and tuned through the PIPSO algorithm so that the Integral of Time multiplied Absolute Error (ITAE between the actual and the desired DC link capacitor voltage reaches a minimum and allows the system to extract maximum power from PV system, whereas the existing d-q control strategy is found to perform slowly to control the DC link voltage under varying solar insolation and load fluctuations. From simulation results, it is evident that the proposed optimal control technique provides robust control and improved efficiency.

  19. Quantum control of coherent π -electron ring currents in polycyclic aromatic hydrocarbons

    Science.gov (United States)

    Mineo, Hirobumi; Fujimura, Yuichi

    2017-12-01

    We present results for quantum optimal control (QOC) of the coherent π electron ring currents in polycyclic aromatic hydrocarbons (PAHs). Since PAHs consist of a number of condensed benzene rings, in principle, there exist various coherent ring patterns. These include the ring current localized to a designated benzene ring, the perimeter ring current that flows along the edge of the PAH, and the middle ring current of PAHs having an odd number of benzene rings such as anthracene. In the present QOC treatment, the best target wavefunction for generation of the ring current through a designated path is determined by a Lagrange multiplier method. The target function is integrated into the ordinary QOC theory. To demonstrate the applicability of the QOC procedure, we took naphthalene and anthracene as the simplest examples of linear PAHs. The mechanisms of ring current generation were clarified by analyzing the temporal evolutions of the electronic excited states after coherent excitation by UV pulses or (UV+IR) pulses as well as those of electric fields of the optimal laser pulses. Time-dependent simulations of the perimeter ring current and middle ring current of anthracene, which are induced by analytical electric fields of UV pulsed lasers, were performed to reproduce the QOC results.

  20. Optimum Peak Current Hysteresis Control for Energy Recovering Converter in CDI Desalination

    Directory of Open Access Journals (Sweden)

    Alberto M. Pernía

    2014-06-01

    Full Text Available Capacitive De-Ionization (CDI is becoming a suitable alternative for desalination. The low cost of the materials required and its reduced energy consumption can be critical factors for developing this technique. CDI technology does not require a high-pressure system and the energy storage capability of CDI cells allows it to be reused in other CDI cells, thus minimizing consumption. The goal of the power stage responsible of the energy recovery is transferring the stored energy from one cell to another with the maximum possible efficiency, thus allowing the desalination process to continue. Assuming hysteresis current control is implemented at the DC/DC (direct current converter, this paper aims to determine the optimum peak current through the inductor in each switching period with a view to maximizing overall efficiency. The geometrical parameters of the desalination cell and the NaCl concentration modify the cell electrical properties. The peak current control of the power stage should be adapted to the cell characteristics so that the efficiency behavior of the whole CDI system can be improved. The mathematical model defined in this paper allows the CDI plant automation using the peak inductor current as control variable, adapting its value to the salt concentration during the desalination process.

  1. Mitigation of grid-current distortion for LCL-filtered grid-connected voltage-source inverter with inverter-side current control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    Due to the low inductance of an LCL-filter, the grid current generated by an LCL-filtered Voltage Source Inverter (VSI) is sensitive to low-order grid-voltage harmonics. This issue is especially tough for the control system with Inverter Current Feedback (ICF), because the grid-current harmonics...... can freely flow into the filter capacitor without control. To cope with this issue, this paper develops an approach for the ICF control system to suppress the grid-current harmonics without adding extra sensors. The proposed method applies harmonic controllers and feedforward scheme simultaneously......, and the instability risk introduced by the feedforward loop can be ingeniously avoided through a special design of the feedforward position, which maintains the inherent stability characteristic of the ICF control system. The effectiveness of the proposed method and the correctness of the theoretical analyses...

  2. Decentralised control method for DC microgrids with improved current sharing accuracy

    DEFF Research Database (Denmark)

    Yang, Jie; Jin, Xinmin; Wu, Xuezhi

    2017-01-01

    A decentralised control method that deals with current sharing issues in dc microgrids (MGs) is proposed in this study. The proposed method is formulated in terms of ‘modified global indicator’ concept, which was originally proposed to improve reactive power sharing in ac MGs. In this work, the ‘...

  3. Small-signal model of a decoupled double synchronous reference frame current controller

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Hjerrild, Jester; Kocewiak, Lukasz

    2016-01-01

    the dq signals are not dc anymore, and therefore, linearization cannot be done. In this paper a Decoupled Double Synchronous Frame PLL is used to eliminate the oscillations in the dq frame signals. The small signal model of this PLL including an unbalanced current controller is presented in this paper....

  4. Current profile control experiments in the LHCD plasma on TRIAM-1M

    International Nuclear Information System (INIS)

    Nakamura, K.; Itoh, S.; Zushi, H.; Sakamoto, M.; Hanada, K.; Jotaki, E.; Pan, Y.D.; Kawasaki, S.; Nakashima, H.

    2001-01-01

    Controllability of current profile in long term discharges is studied by two kinds of combinations of wave spectra. First by superposition of higher N parallel -spectrum wave at 2.45 GHz on a target plasma driven by lower one at 8.2 GHz, a hollow j(r) has been achieved and sustained for 20 sec. The current profile can be well controlled below a threshold power of 14 kW by varying the power of 2.45 GHz. A spontaneous transition phenomenon to a peaked j(r), however, has occurred over the threshold power even after a reasonable steady state condition has been obtained. Second using two opposite travelling waves at 8.2 GHz the total current is clearly reduced and the j(r) becomes peaked when the backward travelling LHWs (BW) are superposed at low power of 20 kW. When the BW power is increased above 27 kW, further current reduction is suppressed, and then above 34 kW the direction of the current driven by BW is completely reversed and the j(r) becomes broad. Thus, current modification by BW shows a highly nonlinear behavior with respect to the BW power. (author)

  5. In-depth porosity control of mesoporous silicon layers by an anodization current adjustment

    Science.gov (United States)

    Lascaud, J.; Defforge, T.; Certon, D.; Valente, D.; Gautier, G.

    2017-12-01

    The formation of thick mesoporous silicon layers in P+-type substrates leads to an increase in the porosity from the surface to the interface with silicon. The adjustment of the current density during the electrochemical etching of porous silicon is an intuitive way to control the layer in-depth porosity. The duration and the current density during the anodization were varied to empirically model porosity variations with layer thickness and build a database. Current density profiles were extracted from the model in order to etch layer with in-depth control porosity. As a proof of principle, an 80 μm-thick porous silicon multilayer was synthetized with decreasing porosities from 55% to 35%. The results show that the assessment of the in-depth porosity could be significantly enhanced by taking into account the pure chemical etching of the layer in the hydrofluoric acid-based electrolyte.

  6. Dynamic Evaluation of LCL-type Grid-Connected Inverters with Different Current Feedback Control Schemes

    DEFF Research Database (Denmark)

    Han, Yang; Li, Zipeng; Guerrero, Josep M.

    2015-01-01

    typical current feedback control schemes in LCL grid-connected system are analyzed and compared systematically. Analysis in s-domain take the effect of the digital computation and modulation delay into account. The stability analysis is presented by root locus in the discrete domain, the optimal values...... of the controller and filter with different feedback configurations are provided. The impacts of digital delay, PR parameters and LCL parameters on different control strategies are also investigated. Finally, the theoretical analysis are validated by simulation results....

  7. Model Predictive Current Control for High-Power Grid-Connected Converters with Output LCL Filter

    DEFF Research Database (Denmark)

    Delpino, Hernan Anres Miranda; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    A model predictive control strategy for a highpower, grid connected 3-level neutral clamped point converter is presented. Power losses constraints set a limit on commutation losses so reduced switching frequency is required, thus producing low frequency current harmonics. To reduce these harmonics...... an LCL filter is used. The proposed control strategy allows control of the active and reactive power fed into the grid, reduce the switching frequency within acceptable operational margins and keep balance of the DC-link capacitor voltages while avoiding excitation of the filter resonance frequencies....

  8. Assessment of current practices in creating and using passwords as a control mechanism for information access

    Directory of Open Access Journals (Sweden)

    P. L. Wessels

    2007-11-01

    Full Text Available One of the critical issues in managing information within an organization is to ensure that proper controls exist and are applied in allowing people access to information. Passwords are used extensively as the main control mechanism to identify users wanting access to systems, applications, data files, network servers or personal information. In this article, the issues involved in selecting and using passwords are discussed and the current practices employed by users in creating and storing passwords to gain access to sensitive information are assessed. The results of this survey conclude that information managers cannot rely only on users to employ proper password control in order to protect sensitive information.

  9. A novel current injection model of PWMSC for control and analysis of power system stability

    Directory of Open Access Journals (Sweden)

    Safari Amin

    2013-01-01

    Full Text Available This paper proposes a novel current injection model of Pulse width Modulation based Series Compensator (PWMSC, as new FACTS controller, for damping of low frequency oscillations. The PWMSC operates as a means of continuous control of the degree of series compensation through the variation of the duty cycle of a train of fixed frequency-pulses. The methodology is tested on the sample single machine power system including PWMSC controller by performing computer simulations for small and large distributions. MATLAB/ Simulink software package was used for the simulations.

  10. Improved PHIP polarization using a precision, low noise, voltage controlled current source.

    Science.gov (United States)

    Agraz, Jose; Grunfeld, Alexander; Cunningham, Karl; Li, Debiao; Wagner, Shawn

    2013-10-01

    Existing para-hydrogen induced polarization (PHIP) instrumentation relies on magnetic fields to hyperpolarize substances. These hyperpolarized substances have enhanced magnetic resonance imaging (MRI) signals over 10,000 fold, allowing for MRI at the molecular level. Required magnetic fields are generated by energizing a solenoid coil with current produced by a voltage controlled voltage source (VCVS), also known as a power supply. A VCVS lacks the current regulation necessary to keep magnetic field fluctuations to a minimum, which results in low PHIP polarization. A voltage controlled current source (VCCS) is an electric circuit that generates a steady flow of electrons proportional to an input voltage. A low noise VCCS provides the solenoid current flow regulation necessary to generate a stable static magnetic field (Bo). We discuss the design and implementation of a low noise, high stability, VCCS for magnetic field generation with minimum variations. We show that a precision, low noise, voltage reference driving a metal oxide semiconductor field effect transistor (MOSFET) based current sink, results in the current flow control necessary for generating a low noise and high stability Bo. In addition, this work: (1) compares current stability for ideal VCVS and VCCS models using transfer functions (TF), (2) develops our VCCS design's TF, (3) measures our VCCS design's thermal & 1/f noise, and (4) measures and compares hydroxyethyl-propionate (HEP) polarization obtained using a VCVS and our VCCS. The hyperpolarization of HEP was done using a PHIP instrument developed in our lab. Using our VCCS design, HEP polarization magnitude data show a statistically significant increase in polarization over using a VCVS. Circuit schematic, bill of materials, board layout, TF derivation, and Matlab simulations code are included as supplemental files. Copyright © 2013 Elsevier Inc. All rights reserved.

  11. DSP Based Control Implementation of an AC/DC Converter with Improved Input Current Distortion

    Directory of Open Access Journals (Sweden)

    WISUTMETHEEKORN, P.

    2011-05-01

    Full Text Available This paper presents a digital signal processor based control of an AC/DC converter with nearly unity power factor. Normally, the output voltage of a single-phase AC/DC converter comprises a voltage ripple with twice line-frequency. This affects the voltage control loop and leads to the converter input current distortion. The purposed method is designed to avoid the effect of the output voltage ripple. To verify the proposed control method, MATLAB/Simulink is used for system simulation. A hardware prototype is setup. A low cost digital signal processing chip dsPIC30F4011 is employed as a digital controller to control a CUK AC/DC converter. The converter specifications are 48V output voltage and 250W output power. From the simulation and the experimental results shown that the input current distortion of the purposed system is reduced and lower than the AC/DC converter that controlled by the conventional proportional-integral controller.

  12. Supervisory control and data acquisition system development for superconducting current feeder system of SST-1

    International Nuclear Information System (INIS)

    Patel, R.; Mahesuria, G.; Gupta, N.C.; Sonara, D.; Panchal, R.; Panchal, P.; Tanna, V.L.; Pradhan, S.

    2014-01-01

    The Current Feeders System (CFS) is essentially an optimized bridge between the power supply at room temperature and Super Conducting Magnet System (SCMS) of the SST-1 machine at 4.5 K.CFS is a complex electrical and cryogenic network which consists of ten pairs of 10 KA rating helium Vapor cooled Conventional Current Leads (VCCLs), superconducting (SC) current feeder and associated components. For the safe and reliable operation of CFS, it is equipped with different physical process parameters measuring instruments like flow, pressure, temperature, level, vacuum, voltage taps and final control element like control valves, heaters, vacuum pumps etc. PLC program is developed in ladder language for acquiring and controlling the process parameters. Independent SCADA applications developed in WonderwareIntouch software for data communication from PLC, front-end Graphical User Interface (GUI), auto-manual interface, real time trends, history trends, events and alarm pages. Time synchronized communication established between CFS control system and Industrial SQL server (InSQL) Historian for centralized storage of CFS process parameters which intern provides the CFS process data to SST-1 central control room. SCADA based data acquisition and data retrieval system is found to be satisfactory during the recent SST-1 cool down experiment. This paper describes the SCADA and PLC application development and their communication to InSQL server. (author)

  13. An inductance Fourier decomposition-based current-hysteresis control strategy for switched reluctance motors

    Science.gov (United States)

    Hua, Wei; Qi, Ji; Jia, Meng

    2017-05-01

    Switched reluctance machines (SRMs) have attracted extensive attentions due to the inherent advantages, including simple and robust structure, low cost, excellent fault-tolerance and wide speed range, etc. However, one of the bottlenecks limiting the SRMs for further applications is its unfavorable torque ripple, and consequently noise and vibration due to the unique doubly-salient structure and pulse-current-based power supply method. In this paper, an inductance Fourier decomposition-based current-hysteresis-control (IFD-CHC) strategy is proposed to reduce torque ripple of SRMs. After obtaining a nonlinear inductance-current-position model based Fourier decomposition, reference currents can be calculated by reference torque and the derived inductance model. Both the simulations and experimental results confirm the effectiveness of the proposed strategy.

  14. A circuit scheme to control current surge for RFID-NVM pumps

    International Nuclear Information System (INIS)

    Li Ming; Kang Jinfeng; Wang Yangyuan; Yang Liwu

    2010-01-01

    This paper presents a new circuit scheme to control the current surge in the boosting phase of an radio frequency idenfication-nonvolative memory pump. By introducing a circuit block consisting of a current reference and a current mirror, the new circuit scheme can keep the period-average current of the pump constantly below the desired level, for example, 2.5 μA. Therefore, it can prevent the rectified supply of the RFID tag IC from collapsing in the boosting phase of the pump. The presented scheme could effectively reduce the voltage drop on the rectified supply from more than 50% to even zero, but could cost less area. Moreover, an analytical expression to calculate the boosting time of a pump in the new scheme is developed. (semiconductor integrated circuits)

  15. A Current-mode Electronically Controllable Multifunction Biquadratic Filter Using CCCIIs

    Directory of Open Access Journals (Sweden)

    MONTREE SIRIPRUCHYANUN

    2013-03-01

    Full Text Available This article presents a current-mode multifunction biquadratic filter performing completely standard functions low-pass, high-pass, band-pass, band-reject and all-pass functions. The circuit principle is based on second-generation current-controlled current conveyor (CCCII with three input terminals and one output terminal. The features of the circuit are that, the pole frequency can be electronically tuned via the input bias currents. The circuit topology is very simple, consisting of merely 2 CCCIIs and 2 grounded capacitors. Without any external resistor and using only grounded elements, the proposed circuit is very comfortable to further develop into an integrated circuit architecture. The PSpice simulation results are shown. The given results agree well with the theoretical anticipation. The total power consumption is approximately 1.87mW at ±1.5V power supply voltages.

  16. Current Controlled Relaxation Oscillations in Ge2Sb2Te5-Based Phase Change Memory Devices

    International Nuclear Information System (INIS)

    Lu Yao-Yao; Cai Dao-Lin; Chen Yi-Feng; Wang Yue-Qing; Wei Hong-Yang; Huo Ru-Ru; Song Zhi-Tang

    2016-01-01

    The relaxation oscillation of the phase change memory (PCM) devices based on the Ge 2 Sb 2 Te 5 material is investigated by applying square current pulses. The current pulses with different amplitudes could be accurately given by the independently designed current testing system. The relaxation oscillation across the PCM device could be measured using an oscilloscope. The oscillation duration decreases with time, showing an inner link with the shrinking threshold voltage V th . However, the relaxation oscillation would not terminate until the remaining voltage V on reaches the holding voltage V h . This demonstrates that the relaxation oscillation might be controlled by V on . The increasing current amplitudes could only quicken the oscillation velocity but not be able to eliminate it, which indicates that the relaxation oscillation might be an inherent behavior for the PCM cell. (paper)

  17. Automated WWER steam generator eddy current testing and plugging control system

    International Nuclear Information System (INIS)

    Gorecan, I.; Gortan, K.; Grzalja, I.

    2004-01-01

    The structural architecture of the system contains three main components which are described as follows: Manipulator Guidance System; Eddy Current Testing System; Plugging System. The manipulator system has the task to position the end-effectors to the desired tube position. When the final position is reached, the Eddy Current testing system performs data acquisition. In case defects are found, the plugging system performs tube plug installment. Each system is composed of 3 layers. The first layer is the hardware layer consisting of motors driving the effectors along with sensors needed to obtain the positioning data, pusher motors used to push the test probes into tubes of the WWER steam generator, and plugging hardware tool. The second layer is the control box performing basic monitoring and control routines as an interconnection between first and third layer. The highest layer is the control software, running on the PC, which is used as a human-machine-interface.(author)

  18. Variable Structure Control of DFIG for Wind Power Generation and Harmonic Current Mitigation

    Directory of Open Access Journals (Sweden)

    BELMADANI, B.

    2010-11-01

    Full Text Available This paper focuses on wind energy conversion system (WECS analysis and control for power generation along with problems related to the mitigation of harmonic pollution in the grid using a variable-speed structure control of the doubly fed induction generator (DFIG. A control approach based on the so-called sliding mode control (SMC that is both efficient and suitable is used for power generation control and harmonic-current compensation. The WECS then behaves as an active power filter (APF. The method aims at improving the overall efficiency, dynamic performance and robustness of the wind power generation system. Simulation results obtained on a 20-kW, 380-V, 50-Hz DFIG confirm the effectiveness of the proposed approach.

  19. The control of the upstream movement of fish with pulsated direct current

    Science.gov (United States)

    McLain, Alberton L.

    1957-01-01

    Alternating-current electromechanical devices installed in the mouths of streams have proved effective in stopping the spawning migrations of the parasitic sea lamprey (Petromyzon marinus) which has seriously damaged Great Lakes fisheries. In a few streams, excessive mortality has occurred to other fish at the alternating-current barriers. A direct-current unit was developed in an attempt to reduce this mortality. This direct-current “diversion device” consists of a row of suspended negative electrodes which begins at the end of a trap wing and extends across the river at a downstream angle of 45° and a series of pipes (positive electrodes) driven into the stream bank. A second array, consisting of horizontal pipes installed downstream and parallel to the suspended electrodes and connected to a series of rods driven into the bank near the positive electrodes, controls the electrical field and dissipates the collecting influence of the positive side of the circuit. The electrical field is established from the end of the trap wing to the opposite bank. Fish are diverted away from the negative electrodes and toward the bank near which the trap is located. The array is activiated by pulsated direct current of essentially square wave shape with pulses at a duty cycle of 0.66 and a repetition rate of 3 per second. Direct-current diversion devices were operated in conjunction with alternating-current barriers during 1956 in the Chocolay River, Marquette County, and the Silver River, Baraga County, Michigan.

  20. New current control based MPPT technique for single stage grid connected PV systems

    International Nuclear Information System (INIS)

    Jain, Sachin; Agarwal, Vivek

    2007-01-01

    This paper presents a new maximum power point tracking algorithm based on current control for a single stage grid connected photovoltaic system. The main advantage of this algorithm comes from its ability to predict the approximate amplitude of the reference current waveform or power that can be derived from the PV array with the help of an intermediate variable β. A variable step size for the change in reference amplitude during initial tracking helps in fast tracking. It is observed that if the reference current amplitude is greater than the array capacity, the system gets unstable (i.e. moves into the positive slope region of the p-v characteristics of the array). The proposed algorithm prevents the PV system from entering the positive slope region of the p-v characteristics. It is also capable of restoring stability if the system goes unstable due to a sudden environmental change. The proposed algorithm has been tested on a new single stage grid connected PV configuration recently developed by the authors to feed sinusoidal current into the grid. The system is operated in a continuous conduction mode to realize advantages such as low device current stress, high efficiency and low EMI. A fast MPPT tracker with single stage inverter topology operating in CCM makes the overall system highly efficient. Specific cases of the system, operating in just discontinuous current mode and discontinuous current mode and their relative merits and demerits are also discussed

  1. Enhancing the Frequency Adaptability of Periodic Current Controllers with a Fixed Sampling Rate for Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    for the periodic signal controllers (e.g., PR and RC) with a fixed sampling rate. In this paper, the impacts of frequency deviations induced by the PLL and/or the grid disturbances on the selected current controllers are investigated by analyzing the frequency adaptability of these current controllers....... Subsequently, strategies to enhance the frequency adaptability of the current controllers are proposed for the power converters to produce high quality feed-in currents even in the presence of grid frequency deviations. Specifically, by feeding back the PLL estimated frequency to update the center frequencies......, which have verified the discussions and the effectiveness of the frequency adaptive current controllers....

  2. Autonomous Control of Current and Voltage Controlled DG Interface Inverters for Reactive Power Sharing and Harmonics Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Mousazadeh, Seyyed Yousef; Jalilain, Alireza; Savaghebi, Mehdi

    2018-01-01

    In microgrids, Voltage Source Inverters (VSIs) interfacing Distributed Generation (DG) units can be operated in Voltage or Current Controlled Modes (VCM/CCM). In this paper, a coordinated control of CCM and VCM units for reactive power sharing and voltage harmonics compensation is proposed....... This decentralized control scheme is based on the local measurement of signals. In this way, the need for communication links is removed which results in a simpler and more reliable structure compared to the communication based control structures. To be more exact, the VCM units contribute to harmonics compensation....... Experimental and simulation studies show that the harmonics compensation is achieved by using only local measurements in presence of virtual admittance/impedance schemes of CCM/VCM units. Furthermore, it is demonstrated that the reactive power sharing among the CCM and VCM units is obtained based...

  3. LED Current Balance Using a Variable Voltage Regulator with Low Dropout vDS Control

    Directory of Open Access Journals (Sweden)

    Hung-I Hsieh

    2017-02-01

    Full Text Available A cost-effective light-emitting diode (LED current balance strategy using a variable voltage regulator (VVR with low dropout vDS control is proposed. This can regulate the multiple metal-oxide-semiconductor field-effect transistors (MOSFETs of the linear current regulators (LCR, maintaining low dropout vDS on the flat vGS-characteristic curves and making all drain currents almost the same. Simple group LCRs respectively loaded with a string LED are employed to implement the theme. The voltage VVdc from a VVR is synthesized by a string LED voltage NvD, source voltage vR, and a specified low dropout vDS = VQ. The VVdc updates instantly, through the control loop of the master LCR, which means that all slave MOSFETs have almost the same biases on their flat vGS-characteristic curves. This leads to all of the string LED currents being equal to each other, producing an almost even luminance. An experimental setup with microchip control is built to verify the estimations. Experimental results show that the luminance of all of the string LEDs are almost equal to one another, with a maximum deviation below 1% during a wide dimming range, while keeping all vDS of the MOSFETs at a low dropout voltage, as expected.

  4. Birth Control in Clinical Trials: Industry Survey of Current Use Practices, Governance, and Monitoring.

    Science.gov (United States)

    Stewart, J; Breslin, W J; Beyer, B K; Chadwick, K; De Schaepdrijver, L; Desai, M; Enright, B; Foster, W; Hui, J Y; Moffat, G J; Tornesi, B; Van Malderen, K; Wiesner, L; Chen, C L

    2016-03-01

    The Health and Environmental Sciences Institute (HESI) Developmental and Reproductive Toxicology Technical Committee sponsored a pharmaceutical industry survey on current industry practices for contraception use during clinical trials. The objectives of the survey were to improve our understanding of the current industry practices for contraception requirements in clinical trials, the governance processes set up to promote consistency and/or compliance with contraception requirements, and the effectiveness of current contraception practices in preventing pregnancies during clinical trials. Opportunities for improvements in current practices were also considered. The survey results from 12 pharmaceutical companies identified significant variability among companies with regard to contraception practices and governance during clinical trials. This variability was due primarily to differences in definitions, areas of scientific uncertainty or misunderstanding, and differences in company approaches to enrollment in clinical trials. The survey also revealed that few companies collected data in a manner that would allow a retrospective understanding of the reasons for failure of birth control during clinical trials. In this article, suggestions are made for topics where regulatory guidance or scientific publications could facilitate best practice. These include provisions for a pragmatic definition of women of childbearing potential, guidance on how animal data can influence the requirements for male and female birth control, evidence-based guidance on birth control and pregnancy testing regimes suitable for low- and high-risk situations, plus practical methods to ascertain the risk of drug-drug interactions with hormonal contraceptives.

  5. Application of PI Current Controller in Single Phase Inverter System Connected to Non Linear Load

    Science.gov (United States)

    Chai Anak Ajot, Tracy; Salimin, Suriana; Aziz, Roziah

    2017-08-01

    This study is concerned with the problem of network power quality when inverter systems are connected to a nonlinear load. Nonlinear loads are well known as one of the biggest source of harmonics in the power system. Besides that, inverter systems also have their nonlinearity characteristic because of the electronic components. As the inverter system is connected to nonlinear load, it resulting in harmonic distortion-related problem and draw non-sinusoidal currents in the system, thus reducing the power quality in the system. The application of Proportional Integral controller in this system is the main interest of this study. This current controller capable of reducing total harmonic distortion and improve the state of current waveform. This paper focuses on application of simple manual trial and error tuning technique to produce the optimum value for the gains. The result of study verifies the trial and error manual tuning of PI current controller in compensating harmonic distortions. Simulation and modelling of the system are successfully developed using Matlab/Simulink.

  6. A Digital Hysteresis Current Control for Half-Bridge Inverters with Constrained Switching Frequency

    Directory of Open Access Journals (Sweden)

    Triet Nguyen-Van

    2017-10-01

    Full Text Available This paper proposes a new robustly adaptive hysteresis current digital control algorithm for half-bridge inverters, which plays an important role in electric power, and in various applications in electronic systems. The proposed control algorithm is assumed to be implemented on a high-speed Field Programmable Gate Array (FPGA circuit, using measured data with high sampling frequency. The hysteresis current band is computed in each switching modulation period based on both the current error and the negative half switching period during the previous modulation period, in addition to the conventionally used voltages measured at computation instants. The proposed control algorithm is derived by solving the optimization problem—where the switching frequency is always constrained at below the desired constant frequency—which is not guaranteed by the conventional method. The optimization problem also keeps the output current stable around the reference, and minimizes power loss. Simulation results show good performances of the proposed algorithm compared with the conventional one.

  7. Variable speed wind turbine generator system with current controlled voltage source inverter

    International Nuclear Information System (INIS)

    Muyeen, S.M.; Al-Durra, Ahmed; Tamura, J.

    2011-01-01

    highlights: → Current controlled voltage source inverter scheme for wind power application. → Low voltage ride through of wind farm. → Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  8. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  9. Current status and prospect of plasma control system for steady-state operation on QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Makoto, E-mail: hasegawa@triam.kyushu-u.ac.jp; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2016-11-15

    Highlights: • Overall configuration of plasma control system on QUEST are presented. • Multi core system and reflective memories are used for the real-time control. • Hall sensors are used for the identification of plasma current and its position. • Repetitive gas fueling with the feed-back control of Hα signal is implemented. - Abstract: The plasma control system (PCS) of QUEST is developed according to the progress of QUEST project. Since one of the critical goals of the project is to achieve the steady-state operation with high temperature vacuum vessel wall, the PCS is also required to have the capability to control the plasma for a long period. For the increase of the loads to processing power of the PCS, the PCS is decentralized with the use of reflective memories (RFMs). The PCS controls the plasma edge position with the real-time identification of plasma current and its position. This identification is done with not only flux loops but also hall sensors. The gas fueling method by piezo valve with monitoring the Hα signal filtered by a digital low-pass filter are proposed and suitable for the steady-state operation on QUEST. The present status and prospect of the PCS are presented with recent topics.

  10. A Novel Electronically Controllable of Current-mode Level Shifted Multicarrier PWM Based on MO-CFTA

    OpenAIRE

    W. Kongnun; A. Aurasopon

    2013-01-01

    This paper proposes the application of an electronically controlled current-mode for a level shifted multicarrier PWM generator. The proposed circuit consists of two multiple-output current follower transconductance amplifiers (MO-CFTAs) for the multiple-output triangular generator and four current follower transconductance amplifiers (CFTAs) for the signal comparator. The characteristics of the circuit are as follows: the current output can be controlled by bias current, the maximum amplitud...

  11. A programmable controller for constant primary peak current in capacitor charging fet switcher for nova

    International Nuclear Information System (INIS)

    Mihalka, A.

    1983-01-01

    New switching power supplies were designed for the 10 mm laser amplifiers in the Nova master oscillator room. The flashlamp supply must be repeatable. Therefore, the authors designed a constant current, linearly charging power supply. Since it is a capacitor, the load varies through-out the charge cycle. At first the load is great, and DI/DT of load current is at a maximum. As the capacitor charges the initial conditions for each cycle change, the power supply in effect sees a smaller capacitance, and DI/DT decreases. We need a way of gradually increasing the on-time of the current pulses so that the transistors in the power bridge are turned off when they reach their maximum peak current. The normal current sense response of the control chip is not fast enough to be useful for the application. The deadtime, or the time that all the bridge transistors are turned off, is fixed so that as the pulse width varies so does the period. We end up with a constant peak current, switching power supply whose frequency varies from 50 khz to 20 khz. Finally, an overcurrent latch protects the transistors from bridge or transformer faults. the circuit is described and results are shown

  12. A Voltage Feedback Based Harmonic Compensation Strategy for Current-Controlled Converters

    DEFF Research Database (Denmark)

    Zhao, Xin; Meng, Lexuan; Xie, Chuan

    2018-01-01

    Harmonics have been considered as one of the major issues in future power grids. With the increasing demand in advanced control functions, power electronic converter interfaced distributed generators (DGs) are expected to perform harmonic compensation when necessary. It has been demonstrated...... in a number of studies that DG converters operating in voltage-controlled mode (VCM) can be easily configured to realize voltage harmonic compensation utilizing naturally embedded voltage control loop. While for DGs operating in current-controlled mode (CCM), such function was rarely studied. Considering...... that CCM is commonly used in renewable energy based generators and energy storage systems, it has certain significance to achieve the same function with CCM converters. Aiming at such objective, this paper proposes a voltage detection based harmonic compensator (HC) for CCM converters. The novelty and main...

  13. THE DUAL CONTROL – A REQUIREMENT OF THE CURRENT BANK MANAGEMENT

    Directory of Open Access Journals (Sweden)

    ALINA MATIȘ

    2014-10-01

    Full Text Available Security is a major problem of the banking industry, which bases its whole system on the reputation the bank manages to establish and then maintain among its customers. With the manifestation of information security issues and in interdependence with them, the need for internal control also developed, both of them being associated with modern risk management practices. As the concept of internal control has been rising as a major concern of management and corporate governance, there are attempts to classify it and distinguish it in different categories, dual control being a result of this process. The authors of this study attempt to present the concept of dual control as it is currently applied in the banking system, trying to analyze contextually its capacities of fraud detection, its consequences in terms of risk and costs as well as its effects on bank performance.

  14. Admittance Modeling of Voltage and Current Controlled Inverter for Harmonic Instability Studies

    DEFF Research Database (Denmark)

    Hoseinzadeh, Bakhtyar; Bak, Claus Leth

    2016-01-01

    This paper proposes an impedance/admittance based model for voltage and current controlled inverters with passive elements suitable for harmonic instability study of grid connected inverters in frequency domain. This linearized model of inverters, significantly simplifies investigation of resonance...... instability and control loop interaction of wind turbines with each other and/or with the grid, while they are installed in wind farms. The derived impedance ratio at point of common connection demonstrates how the inverters participate in harmonic stability of the grid....

  15. Impact of a board-game approach on current smokers: a randomized controlled trial

    OpenAIRE

    Khazaal, Yasser; Chatton, Anne; Prezzemolo, Roberto; Zebouni, Fadi; Edel, Yves; Jacquet, Johan; Ruggeri, Ornella; Burnens, Emilie; Monney, Gr?goire; Protti, Anne-Sylvie; Etter, Jean-Fran?ois; Khan, Riaz; Cornuz, Jacques; Zullino, Daniele

    2013-01-01

    Background The main objective of our study was to assess the impact of a board game on smoking status and smoking-related variables in current smokers. To accomplish this objective, we conducted a randomized controlled trial comparing the game group with a psychoeducation group and a waiting-list control group. Methods The following measures were performed at participant inclusion, as well as after a 2-week and a 3-month follow-up period: “Attitudes Towards Smoking Scale” (ATS-18), “Smoking S...

  16. Single Phase Current-Source Active Rectifier for Traction: Control System Design and Practical Problems

    Directory of Open Access Journals (Sweden)

    Jan Michalik

    2006-01-01

    Full Text Available This research has been motivated by industrial demand for single phase current-source active rectifier dedicated for reconstruction of older types of dc machine locomotives. This paper presents converters control structure design and simulations. The proposed converter control is based on the mathematical model and due to possible interaction with railway signaling and required low switching frequency employs synchronous PWM. The simulation results are verified by experimental tests performed on designed laboratory prototype of power of 7kVA

  17. Guest Editorial: Flexible Operation and Control for Medium Voltage Direct-Current (MVDC) Grid

    DEFF Research Database (Denmark)

    Li, Yong; Guerrero, Josep M.; Siano, Pierluigi

    2017-01-01

    We appreciate very much the support from the IET Power Electronics editorial board for this Special Issue on ‘Flexible Operation and Control for Medium Voltage Direct-Current (MVDC) Grid’. In this final version for publication, 15 papers have been selected for this Special Issue. Three papers...... relate to the topology of MVDC converter, four papers relate to the control of MVDC converter, four papers relate to the introduction of application fields of MVDC grid, and four papers relate to the semiconductor power device and drives towards the application in the medium- and high-voltage DC grid....

  18. ALARM-subsystem of automation control system (ASUS) of high current phasotron (''F'' installation)

    International Nuclear Information System (INIS)

    Anosov, V.N.; Krug, H.

    1982-01-01

    A component of automation control system (ASUS) - so-called ALARM subsystem - of JINR high current phasotron is described. The system consists of high speed scanning system (SSS), the de-- vice for preliminary conversion of signals of accelerotor monitors (APOS) and of appropriate software. SSS ALARM subsystems consist of CAMAC modules of Laboratory of Nuclear Problems, and of ''Electronika 60'' microcomputers. Execution time of its parameters is 0.5 ms by normal regime and 1.0 ms for refusals it finds. Principles of ALARM data processing are general applicable for control of multiparameter systems [ru

  19. GENERATING OF OPTIMAL QUANTIZATION LEVELS OF CONTROL CURRENTS FOR LINEAR STEPPING DRIVES OF PRECISION MOTION SYSTEMS

    Directory of Open Access Journals (Sweden)

    I. V. Dainiak

    2014-01-01

    Full Text Available The paper proposes a method of taking into account accumulated and temperature errors while forming coordinate discrete grid of a linear stepping drive. An algorithm for determination of optimal quantization levels of control currents of drive's phases has been developed in the paper; it minimizes an error of positioning that forms correction files for application of a control system in the software. Investigations on stability of discrete grid nodes coordinates have been carried our with the help of a monitoring station for accurate parameters of linear stepping drive. The investigations have proved an efficiency of the proposed algorithm and methodology for forming coordinate discrete grid.

  20. Grid-Current-Feedback Control for LCL-Filtered Grid Converters With Enhanced Stability

    DEFF Research Database (Denmark)

    Xin, Zhen; Wang, Xiongfei; Loh, Poh Chiang

    2017-01-01

    This paper proposes a Second-Order-Generalized- Integrator (SOGI)-based time delay compensation method for extending the stable region of dual-loop Grid-Current-Feedback (GCF) control system. According to the analysis, stable region of the dual-loop system should be designed below a certain...... critical frequency, before time delay compensation method can be applied. To always meet the requirement, relationship between single-loop converter-current-feedback and dual-loop GCF control is clarified, before a robust inner-loop gain for the dualloop GCF scheme is determined. Enforcing this gain allows...... the converter to remain in its stable region, regardless of how its LCL-filter parameters and grid impedance vary. The SOGIbased delay compensation method can then be applied for widening the stable region of the dual-loop GCF scheme, as proven through s-domain Bode diagrams and z-domain root loci...

  1. Controlling the Er content of porous silicon using the doping current intensity

    KAUST Repository

    Mula, Guido

    2014-07-04

    The results of an investigation on the Er doping of porous silicon are presented. Electrochemical impedance spectroscopy, optical reflectivity, and spatially resolved energy dispersive spectroscopy (EDS) coupled to scanning electron microscopy measurements were used to investigate on the transient during the first stages of constant current Er doping. Depending on the applied current intensity, the voltage transient displays two very different behaviors, signature of two different chemical processes. The measurements show that, for equal transferred charge and identical porous silicon (PSi) layers, the applied current intensity also influences the final Er content. An interpretative model is proposed in order to describe the two distinct chemical processes. The results can be useful for a better control over the doping process.

  2. Modeling and Controller Design of PV Micro Inverter without Using Electrolytic Capacitors and Input Current Sensors

    Directory of Open Access Journals (Sweden)

    Faa Jeng Lin

    2016-11-01

    Full Text Available This paper outlines the modeling and controller design of a novel two-stage photovoltaic (PV micro inverter (MI that eliminates the need for an electrolytic capacitor (E-cap and input current sensor. The proposed MI uses an active-clamped current-fed push-pull DC-DC converter, cascaded with a full-bridge inverter. Three strategies are proposed to cope with the inherent limitations of a two-stage PV MI: (i high-speed DC bus voltage regulation using an integrator to deal with the 2nd harmonic voltage ripples found in single-phase systems; (ii inclusion of a small film capacitor in the DC bus to achieve ripple-free PV voltage; (iii improved incremental conductance (INC maximum power point tracking (MPPT without the need for current sensing by the PV module. Simulation and experimental results demonstrate the efficacy of the proposed system.

  3. Ultrafast terahertz control of extreme tunnel currents through single atoms on a silicon surface

    DEFF Research Database (Denmark)

    Jelic, Vedran; Iwaszczuk, Krzysztof; Nguyen, Peter H.

    2017-01-01

    Ultrafast control of current on the atomic scale is essential for future innovations in nanoelectronics. Extremely localized transient electric fields on the nanoscale can be achieved by coupling picosecond duration terahertz pulses to metallic nanostructures. Here, we demonstrate terahertz...... scanning tunnelling microscopy (THz-STM) in ultrahigh vacuum as a new platform for exploring ultrafast non-equilibrium tunnelling dynamics with atomic precision. Extreme terahertz-pulse-driven tunnel currents up to 10(7) times larger than steady-state currents in conventional STM are used to image...... individual atoms on a silicon surface with 0.3nm spatial resolution. At terahertz frequencies, the metallic-like Si(111)-(7 x 7) surface is unable to screen the electric field from the bulk, resulting in a terahertz tunnel conductance that is fundamentally different than that of the steady state. Ultrafast...

  4. Adaptation of the MAST passive current simulation model for real-time plasma control

    International Nuclear Information System (INIS)

    McArdle, G.J.; Taylor, D.

    2008-01-01

    Successful equilibrium reconstruction on MAST depends on a reliable estimate of the passive current induced in the thick vacuum vessel (which also acts as the load assembly) and other toroidally continuous internal support structures. For the EFIT reconstruction code, a pre-processing program takes the measured plasma and PF coil current evolution and uses a sectional model of the passive structure to solve the ODEs for electromagnetic induction. The results are written to a file, which is treated by EFIT as a set of virtual measurements of the passive current in each section. However, when a real-time version of EFIT was recently installed in the MAST plasma control system, a similar function was required for real-time estimation of the instantaneous passive current. This required several adaptation steps for the induction model to reduce the computational overhead to the absolute minimum, whilst preserving accuracy of the result. These include: ·conversion of the ODE to use an auxiliary variable, avoiding the need to calculate the time derivative of current; ·minimise the order of the system via model reduction techniques with a state-space representation of the problem; ·transformation to eigenmode form, to diagonalise the main matrix for faster computation; ·discretisation of the ODE; ·hand-optimisation to use vector instruction extensions in the real-time processor; ·splitting the task into two parts: the time-critical feedback part, and the next cycle pre-calculation part. After these optimisations, the algorithm was successfully implemented at a cost of just 65 μs per 500 μs control cycle, with only 27 μs added to the control latency. The results show good agreement with the original off-line version. Some of these optimisations have also been used subsequently to improve the performance of the off-line version

  5. Independent gate control of injected and detected spin currents in CVD graphene nonlocal spin valves

    Science.gov (United States)

    Anugrah, Yoska; Hu, Jiaxi; Stecklein, Gordon; Crowell, Paul A.; Koester, Steven J.

    2018-01-01

    Graphene is an ideal material for spintronic devices due to its low spin-orbit coupling and high mobility. One of the most important potential applications of graphene spintronics is for use in neuromorphic computing systems, where the tunable spin resistance of graphene can be used to apply analog weighting factors. A key capability needed to achieve spin-based neuromorphic computing systems is to achieve distinct regions of control, where injected and detected spin currents can be tuned independently. Here, we demonstrate the ability to achieve such independent control using a graphene spin valve geometry where the injector and detector regions are modulated by two separate bottom gate electrodes. The spin transport parameters and their dependence on each gate voltage are extracted from Hanle precession measurements. From this analysis, local spin transport parameters and their dependence on the local gate voltage are found, which provide a basis for a spatially-resolved spin resistance network that simulates the device. The data and model are used to calculate the spin currents flowing into, through, and out of the graphene channel. We show that the spin current flowing through the graphene channel can be modulated by 30% using one gate and that the spin current absorbed by the detector can be modulated by 50% using the other gate. This result demonstrates that spin currents can be controlled by locally tuning the spin resistance of graphene. The integration of chemical vapor deposition (CVD) grown graphene with local gates allows for the implementation of large-scale integrated spin-based circuits.

  6. Control of plasma process by use of harmonic frequency components of voltage and current

    Science.gov (United States)

    Miller, Paul A.; Kamon, Mattan

    1994-01-01

    The present invention provides for a technique for taking advantage of the intrinsic electrical non-linearity of processing plasmas to add additional control variables that affect process performance. The technique provides for the adjustment of the electrical coupling circuitry, as well as the electrical excitation level, in response to measurements of the reactor voltage and current and to use that capability to modify the plasma characteristics to obtain the desired performance.

  7. Control electron beam oscillation regimes in Pierce diode with overcritical current

    International Nuclear Information System (INIS)

    Rempen, I.S.; Khramov, A.E.

    2001-01-01

    The effect of the delayed feedback on the complex oscillation regimes in the electron flux with the overcritical current in the Pierce diode is studied. The possibility of controlling the oscillation regimes through changing the feedback parameters is shown. The finite-dimensional model, describing the behavior of the electron flux in the Pierce diode hydrodynamic model, is constructed. Its behavior under the effect of the delayed feedback is studied [ru

  8. Precision control of high temperature furnaces using an auxiliary power supply and charged particle current flow

    Science.gov (United States)

    Pollock, G.G.

    1997-01-28

    Two power supplies are combined to control a furnace. A main power supply heats the furnace in the traditional manner, while the power from the auxiliary supply is introduced as a current flow through charged particles existing due to ionized gas or thermionic emission. The main power supply provides the bulk heating power and the auxiliary supply provides a precise and fast power source such that the precision of the total power delivered to the furnace is improved. 5 figs.

  9. Precision control of high temperature furnaces using an auxiliary power supply and charged practice current flow

    Science.gov (United States)

    Pollock, George G.

    1997-01-01

    Two power supplies are combined to control a furnace. A main power supply heats the furnace in the traditional manner, while the power from the auxiliary supply is introduced as a current flow through charged particles existing due to ionized gas or thermionic emission. The main power supply provides the bulk heating power and the auxiliary supply provides a precise and fast power source such that the precision of the total power delivered to the furnace is improved.

  10. A Highly Robust Single-Loop Current Control Scheme for Grid-Connected Inverter with an Improved LCCL Filter Configuration

    DEFF Research Database (Denmark)

    Pan, Donghua; Ruan, Xinbo; Wang, Xiongfei

    2018-01-01

    Single-loop current control is an attractive scheme for the LCL-type grid-connected inverter due to its simplicity and low cost. However, conventional single-loop control schemes, which command either the inverter current or the grid current, are subject to the specific resonance frequency region...

  11. Design and control of the phase current of a brushless dc motor to eliminate cogging torque

    Science.gov (United States)

    Jang, G. H.; Lee, C. J.

    2006-04-01

    This paper presents a design and control method of the phase current to reduce the torque ripple of a brushless dc (BLDC) motor by eliminating cogging torque. The cogging torque is the main source of torque ripple and consequently of speed error, and it is also the excitation source to generate the vibration and noise of a motor. This research proposes a modified current wave form, which is composed of main and auxiliary currents. The former is the conventional current to generate the commutating torque. The latter generates the torque with the same magnitude and opposite sign of the corresponding cogging torque at the given position in order to eliminate the cogging torque. Time-stepping finite element method simulation considering pulse-width-modulation switching method has been performed to verify the effectiveness of the proposed method, and it shows that this proposed method reduces torque ripple by 36%. A digital-signal-processor-based controller is also developed to implement the proposed method, and it shows that this proposed method reduces the speed ripple significantly.

  12. A Novel Optimal Current Trajectory Control Strategy of IPMSM Considering the Cross Saturation Effects

    Directory of Open Access Journals (Sweden)

    Huimin Li

    2017-09-01

    Full Text Available Abstract: The nonlinearity and uncertain variation of machine parameters are always caused by cross coupling and magnetic saturation effects, which are easily neglected in the conventional control strategy. In this paper, a current trajectory control strategy (CTCS is proposed to take the cross coupling and magnetic saturation effects into account under voltage and current constraints. It can be considered as a calculating method considering parameter variation and separating among each iteration step which treats the calculated result of the former step as the initial value of the next step. At first, the torque command is translated into the current reference. Then, the increments between the target value and real value of the torque and the voltage are respectively calculated, which are subsequently converted into the current modification vector in did, diq framework for further analysis. In order to take the influence caused by cross coupling and magnetic saturation effects on the CTCS into consideration, self and mutual inductances are analyzed by finite element analysis (FEA. The results of the simulation and experiment show that the rapid response and robustness on reference speed variation could be achieved by employing the proposed CTCS, and the seamless switching between the constant torque and flux-weakening operation can also be realized.

  13. Current Controlled Magnetization Switching in Cylindrical Nanowires for High-Density 3D Memory Applications

    KAUST Repository

    Mohammed, Hanan

    2018-04-18

    A next-generation memory device utilizing a three-dimensional nanowire system requires the reliable control of domain wall motion. In this letter, domain walls are studied in cylindrical nanowires consisting of alternating segments of cobalt and nickel. The material interfaces acting as domain wall pinning sites, are utilized in combination with current pulses, to control the position of the domain wall, which is monitored using magnetoresistance measurements. Magnetic force microscopy results further confirm the occurrence of current assisted domain wall depinning. Data bits are therefore shifted along the nanowire by sequentially pinning and depinning a domain wall between successive interfaces, a requirement necessary for race-track type memory devices. We demonstrate that the direction, amplitude and duration of the applied current pulses determine the propagation of the domain wall across pinning sites. These results demonstrate a multi-bit cylindrical nanowire device, utilizing current assisted data manipulation. The prospect of sequential pinning and depinning in these nanowires allows the bit density to increase by several Tbs, depending on the number of segments within these nanowires.

  14. Integrated fuzzy-PI controlled current source converter based D-STATCOM

    Directory of Open Access Journals (Sweden)

    M. Deben Singh

    2016-12-01

    Full Text Available The distribution static synchronous compensator (D-STATCOM is a shunt-connected current injection custom power (CP device that can be used for improving quality and reliability of the power supplied to electric consumers under dynamic conditions of the distribution system. The CP devices such as dynamic voltage restorer and unified power quality conditioner including D-STATCOM are mostly designed and implemented using voltage source converter topology. The performance of D-STATCOM can be improved, if it is realized by using a current source converter topology which can generate a controllable current directly at its output terminals. Although the current source converter (CSC topology offers many promising advantageous features, not much research publications with CSC-based approach in the field of CP devices has been reported over the last one decade. This paper presents a novel method of realizing a D-STATCOM using CSC topology with an integrated fuzzy-PI controller for not only mitigating voltage sag but also capable of maintaining improved DC-link voltage profile. The model has been simulated in the MATLAB/SIMULINK environment. The simulation results under steady state and dynamic load perturbation provide excellent output characteristics that support the validity of the proposed model.

  15. A 540-[Formula: see text] Duty Controlled RSSI With Current Reusing Technique for Human Body Communication.

    Science.gov (United States)

    Jang, Jaeeun; Lee, Yongsu; Cho, Hyunwoo; Yoo, Hoi-Jun

    2016-08-01

    An ultra-low-power duty controlled received signal strength indicator (RSSI) is implemented for human body communication (HBC) in 180 nm CMOS technology under 1.5 V supply. The proposed RSSI adopted 3 following key features for low-power consumption; 1) current reusing technique (CR-RSSI) with replica bias circuit and calibration unit, 2) duty controller, and 3) reconfigurable gm-boosting LNA. The CR-RSSI utilizes stacked amplifier-rectifier-cell (AR-cell) to reuse the supply current of each blocks. As a result, the power consumption becomes 540 [Formula: see text] with +/-2 dB accuracy and 75 dB dynamic range. The replica bias circuit and calibration unit are adopted to increase the reliability of CR-RSSI. In addition, the duty controller turns off the RSSI when it is not required, and this function leads 70% power reduction. At last, the gm-boosting reconfigurable LNA can adaptively vary its noise and linearity performance with respect to input signal strength. Fro current reusing technique m this feature, we achieve 62% power reduction in the LNA. Thanks to these schemes, compared to the previous works, we can save 70% of power in RSSI and LNA.

  16. Interlink Converter with Linear Quadratic Regulator Based Current Control for Hybrid AC/DC Microgrid

    Directory of Open Access Journals (Sweden)

    Dwi Riana Aryani

    2017-11-01

    Full Text Available A hybrid alternate current/direct current (AC/DC microgrid consists of an AC subgrid and a DC subgrid, and the subgrids are connected through the interlink bidirectional AC/DC converter. In the stand-alone operation mode, it is desirable that the interlink bidirectional AC/DC converter manages proportional power sharing between the subgrids by transferring power from the under-loaded subgrid to the over-loaded one. In terms of system security, the interlink bidirectional AC/DC converter takes an important role, so proper control strategies need to be established. In addition, it is assumed that a battery energy storage system is installed in one subgrid, and the coordinated control of interlink bidirectional AC/DC converter and battery energy storage system converter is required so that the power sharing scheme between subgrids becomes more efficient. For the purpose of designing a tracking controller for the power sharing by interlink bidirectional AC/DC converter in a hybrid AC/DC microgrid, a droop control method generates a power reference for interlink bidirectional AC/DC converter based on the deviation of the system frequency and voltages first and then interlink bidirectional AC/DC converter needs to transfer the power reference to the over-loaded subgrid. For efficiency of this power transferring, a linear quadratic regulator with exponential weighting for the current regulation of interlink bidirectional AC/DC converter is designed in such a way that the resulting microgrid can operate robustly against various uncertainties and the power sharing is carried out quickly. Simulation results show that the proposed interlink bidirectional AC/DC converter control strategy provides robust and efficient power sharing scheme between the subgrids without deteriorating the secure system operation.

  17. Control of Power Electronic Converters in Distributed Power Generation Systems: Evaluation of Current Control Structures for Voltage Source Converters operating under Weak Grid Conditions

    OpenAIRE

    Midtsund, Tarjei

    2010-01-01

    The performance of different current controller structures for Voltage Source Converters (VSC) under weak grid conditions caused by large grid impedance is investigated. The VSC is synchronized to the grid by a Phase Locked Loop (PLL). Current control techniques and PLL techniques for handling both symmetrical and asymmetrical conditions are presented and discussed. The investigated current control structures are; the conventional Proportional Integral (PI)-controller in the synchronous rotat...

  18. Hysteresis-controlled instability waves in a scale-free driven current sheet model

    Directory of Open Access Journals (Sweden)

    V. M. Uritsky

    2005-01-01

    Full Text Available Magnetospheric dynamics is a complex multiscale process whose statistical features can be successfully reproduced using high-dimensional numerical transport models exhibiting the phenomenon of self-organized criticality (SOC. Along this line of research, a 2-dimensional driven current sheet (DCS model has recently been developed that incorporates an idealized current-driven instability with a resistive MHD plasma system (Klimas et al., 2004a, b. The dynamics of the DCS model is dominated by the scale-free diffusive energy transport characterized by a set of broadband power-law distribution functions similar to those governing the evolution of multiscale precipitation regions of energetic particles in the nighttime sector of aurora (Uritsky et al., 2002b. The scale-free DCS behavior is supported by localized current-driven instabilities that can communicate in an avalanche fashion over arbitrarily long distances thus producing current sheet waves (CSW. In this paper, we derive the analytical expression for CSW speed as a function of plasma parameters controlling local anomalous resistivity dynamics. The obtained relation indicates that the CSW propagation requires sufficiently high initial current densities, and predicts a deceleration of CSWs moving from inner plasma sheet regions toward its northern and southern boundaries. We also show that the shape of time-averaged current density profile in the DCS model is in agreement with steady-state spatial configuration of critical avalanching models as described by the singular diffusion theory of the SOC. Over shorter time scales, SOC dynamics is associated with rather complex spatial patterns and, in particular, can produce bifurcated current sheets often seen in multi-satellite observations.

  19. Health Information System Role-Based Access Control Current Security Trends and Challenges.

    Science.gov (United States)

    de Carvalho Junior, Marcelo Antonio; Bandiera-Paiva, Paulo

    2018-01-01

    This article objective is to highlight implementation characteristics, concerns, or limitations over role-based access control (RBAC) use on health information system (HIS) using industry-focused literature review of current publishing for that purpose. Based on the findings, assessment for indication of RBAC is obsolete considering HIS authorization control needs. We have selected articles related to our investigation theme "RBAC trends and limitations" in 4 different sources related to health informatics or to the engineering technical field. To do so, we have applied the following search query string: "Role-Based Access Control" OR "RBAC" AND "Health information System" OR "EHR" AND "Trends" OR "Challenges" OR "Security" OR "Authorization" OR "Attacks" OR "Permission Assignment" OR "Permission Relation" OR "Permission Mapping" OR "Constraint". We followed PRISMA applicable flow and general methodology used on software engineering for systematic review. 20 articles were selected after applying inclusion and exclusion criteria resulting contributions from 10 different countries. 17 articles advocate RBAC adaptations. The main security trends and limitations mapped were related to emergency access, grant delegation, and interdomain access control. Several publishing proposed RBAC adaptations and enhancements in order to cope current HIS use characteristics. Most of the existent RBAC studies are not related to health informatics industry though. There is no clear indication of RBAC obsolescence for HIS use.

  20. Survey of Current Status of Quality Control of Gamma Cameras in Republic of Korea

    International Nuclear Information System (INIS)

    Choe, Jae Gol; Joh, Cheol Woo

    2008-01-01

    It is widely recognized that good quality control (QC) program is essential for adequate imaging diagnosis using gamma camera. The purpose of this study is to survey the current status of QC of gamma cameras in Republic of Korea for implementing appropriate nationwide quality control guidelines and programs. A collection of data is done for personnel, equipment and appropriateness of each nuclear medicine imaging laboratory's' quality control practice. This survey is done by collection of formatted questionnaire by mails, e mails or interviews. We also reviewed the current recommendations concerning quality assurance by international societies. This survey revealed that practice of quality control is irregular and not satisfactory. The irregularity of the QC practice seems due partly to the lack of trained personnel, equipment, budget, time and hand-on guidelines. The implementation of QC program may cause additional burden to the hospitals, patients and nuclear medicine laboratories. However, the benefit of a good QC program is obvious that the hospitals can provide good quality nuclear medicine imaging studies to the patients. It is important to use least cumbersome QC protocol, to educate the nuclear medicine and hospital administrative personnel concerning QC, and to establish national QC guidelines to help each individual nuclear medicine laboratory

  1. Mathematical analysis and coordinated current allocation control in battery power module systems

    Science.gov (United States)

    Han, Weiji; Zhang, Liang

    2017-12-01

    As the major energy storage device and power supply source in numerous energy applications, such as solar panels, wind plants, and electric vehicles, battery systems often face the issue of charge imbalance among battery cells/modules, which can accelerate battery degradation, cause more energy loss, and even incur fire hazard. To tackle this issue, various circuit designs have been developed to enable charge equalization among battery cells/modules. Recently, the battery power module (BPM) design has emerged to be one of the promising solutions for its capability of independent control of individual battery cells/modules. In this paper, we propose a new current allocation method based on charging/discharging space (CDS) for performance control in BPM systems. Based on the proposed method, the properties of CDS-based current allocation with constant parameters are analyzed. Then, real-time external total power requirement is taken into account and an algorithm is developed for coordinated system performance control. By choosing appropriate control parameters, the desired system performance can be achieved by coordinating the module charge balance and total power efficiency. Besides, the proposed algorithm has complete analytical solutions, and thus is very computationally efficient. Finally, the efficacy of the proposed algorithm is demonstrated using simulations.

  2. Experimental Results of a DC Bus Voltage Level Control for a Load-Controlled Marine Current Energy Converter

    Directory of Open Access Journals (Sweden)

    Johan Forslund

    2015-05-01

    Full Text Available This paper investigates three load control methods for a  marine current energy converter using a vertical axis current  turbine (VACT mounted on a permanent magnet synchronous generator  (PMSG. The three cases are; a fixed AC load, a fixed pulse width  modulated (PWM DC load and DC bus voltage control of a DC  load. Experimental results show that the DC bus voltage control  reduces the variations of rotational speed by a factor of 3.5 at the cost  of slightly increased losses in the generator and transmission lines.  For all three cases, the tip speed ratio \\(\\lambda\\ can be kept close to  the expected \\(\\lambda_{opt}\\. The power coefficient is estimated to be  0.36 at \\(\\lambda_{opt}\\; however, for all three cases, the average  extracted power was about \\(\\sim 19\\\\%. A maximum power point  tracking (MPPT system, with or without water velocity measurement,  could increase the average extracted power.

  3. Virtual-Impedance-Based Control for Voltage-Source and Current-Source Converters

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Li, YunWei; Blaabjerg, Frede

    2015-01-01

    The virtual impedance concept is increasingly used for the control of power electronic systems. Generally, the virtual impedance loop can either be embedded as an additional degree of freedom for active stabilization and disturbance rejection, or be employed as a command reference generator....... Different virtual impedances and their implementation issues are then discussed. A number of practical examples are demonstrated to illustrate the feasibility of virtual impedances. Emerging applications and future trends of virtual impedances in power electronic systems conclude this paper....... for the converters to provide ancillary services. This paper presents an overview of the virtual-impedance-based control strategies for voltage-source and current-source converters. The control output impedance shaping attained by the virtual impedances is generalized first using the impedance-based models...

  4. Hysteretic self-oscillating bandpass current mode control for Class D audio amplifiers driving capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    A hysteretic self-oscillating bandpass current mode control (BPCM) scheme for Class D audio amplifiers driving capacitive transducers are presented. The scheme provides excellent stability margins and low distortion over a wide range of operating conditions. Small-signal behavior of the amplifier...... is analysis through transfer function based linear control methodology. Measurements are performed on a single-ended ± 300 V half-bridge amplifier driving a capacitive load of 100 nF. Total Harmonic Distortion plus noise (THD+N) below 0.1 % are reported. Transducers representing a capacitive load and obeying...... the rules of electrostatics have been known as very interesting alternatives to the traditional inefficient electrodynamic transducers. When driving capacitive transducers from a Class D audio amplifier the high impedance nature of the load represents a key challenge. The BPCM control scheme ensures a flat...

  5. Feedback control modeling of plasma position and current during intense heating in ISX-B

    International Nuclear Information System (INIS)

    Charlton, L.A.; Swain, D.W.; Neilson, G.H.

    1979-08-01

    The ISX-B Tokamak at ORNL is designed to have 1.8 MW (and eventually 3 MW) of neutral beam power injected to heat the plasma. This power may raise the anti β of the plasma to over 5% in less than 50 msec if the plasma is MHD stable. The results of a numerical simulation of the feedback control system and poloidal coil power supplies necessary to control the resulting noncircular (D-shaped or elliptical) plasma are presented. The resulting feedback control system is shown to be straightforward, although nonlinear voltage-current dependence is assumed in the power supplies. The required power supplied to the poloidal coils in order to contain the plasma under the high heating rates is estimated

  6. Digital driver of alternate current motors of the control rods in a nuclear research reactor

    International Nuclear Information System (INIS)

    Sainz M, E.

    1996-01-01

    The updating of the instruments as the operation console of the TRIGA Mark III Salazar Reactor is based on the use of a personal computer that works as data acquisition and control device. The power changes on the reactor have been made through the inserting or extraction of four control rods, that they are operated by mechanisms based in alternate current motors. That is with the object to handling each of the bars and so avoiding too the degradation about the performance of the computer of process. Also it is using four drives of smart kind which do the basic duties for generating the control signals and verifying the sensors state of the limits in continuous form. The computer and drivers are organized as a ring net using the serial port R S-232. The computer of process sends the orders and the identification of destination instrument throughout the net. (Author)

  7. Enhancing the Frequency Adaptability of Periodic Current Controllers with a Fixed Sampling Rate for Grid-Connected Power Converters

    OpenAIRE

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2016-01-01

    Grid-connected power converters should employ advanced current controllers, e.g., Proportional Resonant (PR) and Repetitive Controllers (RC), in order to produce high-quality feed-in currents that are required to be synchronized with the grid. The synchronization is actually to detect the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is commonly performed by a Phase-Locked-Loop (PLL) system. Hence, harmonics and deviations in the...

  8. Transgenesis and paratransgenesis to control insect-borne diseases: Current status and future challenges

    Science.gov (United States)

    Coutinho-Abreu, Iliano V.; Zhu, Kun Yan; Ramalho-Ortigao, Marcelo

    2009-01-01

    Insect-borne diseases cause significant human morbidity and mortality. Current control and preventive methods against vector-borne diseases rely mainly on insecticides. The emergence of insecticide resistance in many disease vectors highlights the necessity to develop new strategies to control these insects. Vector transgenesis and paratransgenesis are novel strategies that aim at reducing insect vectorial capacity, or seek to eliminate transmission of pathogens such as Plasmodium sp., Trypanosoma sp., and Dengue virus currently being developed. Vector transgenesis relies on direct genetic manipulation of disease vectors making them incapable of functioning as vectors of a given pathogen. Paratransgenesis focuses on utilizing genetically modified insect symbionts to express molecules within the vector that are deleterious to pathogens they transmit. Despite the many successes achieved in developing such techniques in the last several years, many significant barriers remain and need to be overcome prior to any of these approaches become a reality. Here, we highlight the current status of these strategies, pointing out advantages and constraints, and also explore issues that need to be resolved before the establishment of transgenesis and paratransgenesis as tools to prevent vector-borne diseases. PMID:19819346

  9. Adaptive Hysteresis Band Current Control (AHB) with PLL of Grid Side Converter-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2011-01-01

    Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given. Then ......, transformer and grid, and control parts, etc. The simulation results have verified that the control strategy is feasible to fit for control of gird currents, active power, reactive power and DC-link voltage in wind power generation system.......Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given...

  10. Innovative current mode voltage mode control for distributed energy generation static systems; Controle inovador modo corrente modo tensao para sistemas estaticos de geracao distribuida de energia

    Energy Technology Data Exchange (ETDEWEB)

    Oliveira Junior, Azauri Albano de; Maciel, Carlos Dias; Cichy, Elineri Cassia C.; Gongora, Vicente de Lima [Universidade de Sao Paulo (EESC/USP), Sao Carlos, SP (Brazil). Escola de Engenharia], Emails: azaurijr@sel.eesc.usp.br, maciel@sel.eesc.usp.br, elineri@uol.com.br, vicente@ldapalm.com.br; Barbosa, Lucio dos Reis [Universidade Estadual de Londrina (UEL), PR (Brazil)], Email: lbarbosa@uel.br; Pereira, Adriano Alves [Universidade Federal de Uberlandia (UFU), MG (Brazil)], Email: aapereira@ufu.br

    2006-07-01

    This work focuses on control of power inverter technologies for connecting any possible Dc energy system to a single-phase using a Current Mode Voltage Mode Control-CMVMC. In this way a CMVMC can control only one power inverter in two operation modes. In current mode the control inject the active power in the utility and voltage control keeping loads always on with energy from the alternative DC sources. When installed near big centers the control will choose the correctly operation or current mode or voltage mode depend on if the utility is present or no. This advanced, robust control strategies can determine the maximum on-line limit current from the DC energy, without DC current component and also free of island operation. The feasibility of this new control was digitally simulated and implemented in analogic way. (author)

  11. Ocean Current Energy Conversion System in Wallacea Region Using Variable Speed Control Approach

    Directory of Open Access Journals (Sweden)

    Aditya Sukma Nugraha

    2012-03-01

    Full Text Available Ocean Current Energy Conversion System (OCECS is a promising green energy resource in this globe. The Thermohaline circulation data indicates that the Wallacea region has the potential of ocean current energy resources. This paper is aimed to propose research and development of OCECSs to be implemented in the Wallacea region. Firstly, four types of green energy conversion systems extracted from ocean are reviewed. Their advantages and disadvantages are discussed. Secondly, the potential of OCECS in the Wallacea region is described. Third, many types of turbines used for OCECS are reviewed and the turbine type for OCECS is selected to be implemented in the Wallacea region. Fourth, control strategy is proposed.From the work reported in this paper it is concluded that it is appropriate to implement OCECSs using axial flow water turbines in the Wallacea region, and that to maximize energy conversion variable speed control approach is selected together with control of mechanism to move the turbine vertically as well as to rotate the turbine in yaw direction. 

  12. Infection prevention and control measures currently applied in South African audiology

    Directory of Open Access Journals (Sweden)

    Katerina Ehlert

    2014-11-01

    Objective: The primary aim of the study was to ascertain the methods that audiologists in South Africa use to prevent and control the spread of infections during and after consultation with clients. Method: A survey study was conducted, using a self-administered questionnaire. Fifty currently practising audiologists participated in the study. Results: The majority (84%; n = 42 of respondents acknowledged the importance of hand hygiene for the purpose of infection control, with 76% (n = 38 making use of no-rinse hand sanitisers. Approximately a third of audiologists wear gloves during procedures such as otoscopy and immittance, and while handling hearing aids. Disinfecting audiological equipment seem to be the preferred choice of infection control, with only 60% (n = 30 of respondents sterilising audiological equipment after each individual patient consultation. Less than half of the respondents disinfected touch surfaces and toys in the reception area. Conclusions: Based on the results, further education and training should focus on measures implemented in infection control, awareness of possible risk factors at work settings, and vaccination as an effective means of infection control.

  13. Low Voltage Ride-through in DFIG Wind Generators by Controlling the Rotor Current without Crowbars

    Directory of Open Access Journals (Sweden)

    Jaime Rodríguez Arribas

    2014-01-01

    Full Text Available Among all the different types of electric wind generators, those that are based on doubly fed induction generators, or DFIG technology, are the most vulnerable to grid faults such as voltage sags. This paper proposes a new control strategy for this type of wind generator, that allows these devices to withstand the effects of a voltage sag while following the new requirements imposed by grid operators. This new control strategy makes the use of complementary devices such as crowbars unnecessary, as it greatly reduces the value of currents originated by the fault. This ensures less costly designs for the rotor systems as well as a more economic sizing of the necessary power electronics. The strategy described here uses an electric generator model based on space-phasor theory that provides a direct control over the position of the rotor magnetic flux. Controlling the rotor magnetic flux has a direct influence on the rest of the electrical variables enabling the machine to evolve to a desired work point during the transient imposed by the grid disturbance. Simulation studies have been carried out, as well as test bench trials, in order to prove the viability and functionality of the proposed control strategy.

  14. Current Control and Performance Evaluation of Converter Interfaced Distribution Resources in Grid Connected Mode

    Directory of Open Access Journals (Sweden)

    SINGH Alka

    2012-10-01

    Full Text Available Use of distributed resources is growing in developing countries like India and in developed nations too. The increased acceptance of suchresources is mainly due to their modularity, increased reliability, good power quality and environment friendly operation. These are currently being interfaced to the existing systems using voltage source inverters (VSC’s. The control of such distributed resources is significantly different than the conventional power systems mainly because the VSC’s have no inertia unlike the synchronous generators.This paper deals with the Matlab modeling and design of control aspects of one such distributed source feeding a common load. A grid connected supply is also available. The control algorithm is developed for real and reactive power sharing of the load between thedistributed source and the grid. The developed control scheme is tested for linear (R-L load as well as nonlinear loads. With suitable modifications, the control algorithm can be extended for several distributed resources connected in parallel.

  15. Multichannel computerized control system of current pulses in LIU-30 electron accelerator

    CERN Document Server

    Gerasimov, A I; Kulgavchuk, V V; Pluzhnikov, A V

    2002-01-01

    In LIU-30 power linear pulsed induction electron accelerator (40 MeV, 10 kA, 25 ns) 288 radial lines with water insulation serve as energy accumulators and shapers of accelerating voltage pulses. The lines are charged simultaneously up to 500 kV using a system comprising 72 Arkadiev-Marx screened generators. To control parameter of synchronous pulses of charging current with up to 60 kA amplitude and 0.85 mu s duration in every of 72 charging circuits one applies a computer-aided system. Current pulse is recorded at output of every generator using the Rogowski coil signal from which via a cable line is transmitted to an analog-digital converter, is processed with 50 ns sampling and is recorded to a memory unit. Upon actuation of accelerator the signals are sequentially or selectively displayed and are compared with pulse typical shape

  16. A Grid Connected Transformerless Inverter and its Model Predictive Control Strategy with Leakage Current Elimination Capability

    Directory of Open Access Journals (Sweden)

    J. Fallah Ardashir

    2017-06-01

    Full Text Available This paper proposes a new single phase transformerless Photovoltaic (PV inverter for grid connected systems. It consists of six power switches, two diodes, one capacitor and filter at the output stage. The neutral of the grid is directly connected to the negative terminal of the source. This results in constant common mode voltage and zero leakage current. Model Predictive Controller (MPC technique is used to modulate the converter to reduce the output current ripple and filter requirements. The main advantages of this inverter are compact size, low cost, flexible grounding configuration. Due to brevity, the operating principle and analysis of the proposed circuit are presented in brief. Simulation and experimental results of 200W prototype are shown at the end to validate the proposed topology and concept. The results obtained clearly verifies the performance of the proposed inverter and its practical application for grid connected PV systems.

  17. Current status and perspectives of Clonorchis sinensis and clonorchiasis: epidemiology, pathogenesis, omics, prevention and control.

    Science.gov (United States)

    Tang, Ze-Li; Huang, Yan; Yu, Xin-Bing

    2016-07-06

    Clonorchiasis, caused by Clonorchis sinensis (C. sinensis), is an important food-borne parasitic disease and one of the most common zoonoses. Currently, it is estimated that more than 200 million people are at risk of C. sinensis infection, and over 15 million are infected worldwide. C. sinensis infection is closely related to cholangiocarcinoma (CCA), fibrosis and other human hepatobiliary diseases; thus, clonorchiasis is a serious public health problem in endemic areas. This article reviews the current knowledge regarding the epidemiology, disease burden and treatment of clonorchiasis as well as summarizes the techniques for detecting C. sinensis infection in humans and intermediate hosts and vaccine development against clonorchiasis. Newer data regarding the pathogenesis of clonorchiasis and the genome, transcriptome and secretome of C. sinensis are collected, thus providing perspectives for future studies. These advances in research will aid the development of innovative strategies for the prevention and control of clonorchiasis.

  18. Is the current therapeutic armamentarium in diabetes enough to control the epidemic and its consequences? What are the current shortcomings?

    DEFF Research Database (Denmark)

    Giugliano, Dario; Standl, Eberhard; Vilsbøll, Tina

    2009-01-01

    The prevalence of diabetes is expected to rise together with an increase in morbidity and a reduction in life expectancy. A leading cause of death is cardiovascular disease, and hypertension and diabetes are additive risk factors for this complication. Selected treatment options should neither...... increase cardiovascular risk in patients with diabetes, nor increase risk of hyperglycaemia in patients with hypertension. The efficacy of present antihyperglycaemic agents is limited and new therapies, such as incretin-targeted agents, are under development. Even though most patients do not achieve...... glycated haemoglobin targets, trial data show that such interventions reduce the incidence of macrovascular events; however, intensive lowering may be detrimental in patients with existing cardiovascular disease. Currently available oral drugs do not address the key driver of type 2 diabetes...

  19. Cognitive control therapy and transcranial direct current stimulation for depression: a randomized, double-blinded, controlled trial.

    Science.gov (United States)

    Brunoni, A R; Boggio, P S; De Raedt, R; Benseñor, I M; Lotufo, P A; Namur, V; Valiengo, L C L; Vanderhasselt, M A

    2014-06-01

    Based on findings that major depressive disorder (MDD) is associated to decreased dorsolateral prefrontal cortical (DLPFC) activity; interventions that increase DLPFC activity might theoretically present antidepressant effects. Two of them are cognitive control therapy (CCT), a neurocognitive intervention that uses computer-based working memory exercises, and transcranial direct current stimulation (tDCS), which delivers weak, electric direct currents over the scalp. We investigated whether tDCS enhanced the effects of CCT in a double-blind trial, in which participants were randomized to sham tDCS and CCT (n=17) vs. active tDCS and CCT (n=20). CCT and tDCS were applied for 10 consecutive workdays. Clinicaltrials.gov identifier: NCT01434836. Both CCT alone and combined with tDCS ameliorated depressive symptoms after the acute treatment period and at follow-up, with a response rate of approximately 25%. Older patients and those who presented better performance in the task throughout the trial (possibly indicating greater engagement and activation of the DLPFC) had greater depression improvement in the combined treatment group. Our exploratory findings should be further confirmed in prospective controlled trials. CCT and tDCS combined might be beneficial for older depressed patients, particularly for those who have cognitive resources to adequately learn and improve task performance over time. This combined therapy might be specifically relevant in this subgroup that is more prone to present cognitive decline and prefrontal cortical atrophy. Copyright © 2014 Elsevier B.V. All rights reserved.

  20. Current profile control and magnetohydrodynamic stability in Tore Supra discharges with edge-plasma control by the ergodic divertor

    International Nuclear Information System (INIS)

    Zabiego, M.; Friant, C.; Ghendrih, P.; Becoulet, M.; Bucalossi, J.; Saint-Laurent, F.

    1999-01-01

    Although ergodic divertors are primarily designed to control particle and heat fluxes at the plasma edge, they also happen to affect the MHD stability of tokamak discharges. On Tore Supra, the ergodic divertor has long been known to stabilize the m/n=2/1 tearing mode induced, for instance, by edge radiation and detachment processes, thus allowing safe high-current and high-density operations. More recently, though, in discharges where ergodic divertor operations were optimised relative to the control of the edge-plasma (i.e., with large divertor perturbation), a detrimental increase in the disruptiveness has been observed. The action that the ergodic divertor has on the MHD activity is interpreted in terms of a redistribution of the current profile. The latter results from a large increase in the edge resistivity, primarily induced by the degradation of the electron energy confinement in the ergodic layer. The possibility that a transport barrier develops in the vicinity of the separatrix strongly affects the considered modelling. (authors)

  1. Fault-tolerant control for current sensors of doubly fed induction generators based on an improved fault detection method

    DEFF Research Database (Denmark)

    Li, Hui; Yang, Chao; Hu, Yaogang

    2014-01-01

    Fault-tolerant control of current sensors is studied in this paper to improve the reliability of a doubly fed induction generator (DFIG). A fault-tolerant control system of current sensors is presented for the DFIG, which consists of a new current observer and an improved current sensor fault...... detection algorithm. The current observer is constructed by using only voltage signals as inputs. The fault detection algorithm is based on the current observer, in which an adaptive threshold and different fault duration times are considered. The performance of the proposed observer, improved fault...... detection algorithm, and fault-tolerant control system are investigated by simulation. The results indicate that the outputs of the observer and the sensor are highly coherent. The fault detection algorithm can efficiently detect both soft and hard faults in current sensors, and the fault-tolerant control...

  2. Control of plasma position in TEXTOR tokamak applying a method of multipole moments of plasma current

    International Nuclear Information System (INIS)

    Kardon, B.; Soltwitsch, H.; Waidmann, G.

    1987-07-01

    On the basis of a method developed by Zakharov and Shafranov for the determination of the plasma cross section in toroidal geometry two special pick-up coils for the two components of the poloidal magnetic field were built. A cosine coil of higher order and a saddle coil were designed and installed outside the plasma column. The proper sum of these two signals permits the evaluation of the first momentum of the plasma current which is the equilibrium plasma displacement. The horizontal position of the plasma column was controlled on-line by the TEXTOR feedback system using this analog sum signal. (orig.)

  3. Realization of Resistorless Wave Active Filter using Differential Voltage Current Controlled Conveyor Transconductance Amplifier

    Directory of Open Access Journals (Sweden)

    N. Pandey

    2011-12-01

    Full Text Available In this paper, a resistorless realization of high order voltage mode wave active filter based on Differential Voltage current controlled conveyor transconductance amplifier (DVCCCTA is presented. The wave method is used for simulating reflected and incident wave for basic building block i.e. series inductor and configuring it for other passive element realization by making appropriate connection. The proposed structure uses grounded capacitors and possesses electronic tunability of cutoff frequency. The proposed approach is verified for a 4th order low pass filter through SPICE simulation using 0.25µm TSMC CMOS technology parameters.

  4. Multi-terminal direct-current grids modeling, analysis, and control

    CERN Document Server

    Chaudhuri, Nilanjan; Majumder, Rajat; Yazdani, Amirnaser

    2014-01-01

    A comprehensive modeling, analysis, and control design framework for multi-terminal direct current (MTDC) grids is presented together with their interaction with the surrounding AC networks and the impact on overall stability. The first book of its kind on the topic of multi-terminal DC (MTDC) grids  Presents a comprehensive modeling framework for MTDC grids which is compatible with the standard AC system modeling for stability studies Includes modal analysis and study of the interactions between the MTDC grid and the surrounding AC systems Addresses the problems of autonomous power sharing an

  5. Control and Calibration of a Staubli RX130 Robotic Arm for Construction of Surface Current Coils

    Science.gov (United States)

    Vanmeter, Patrick; Crawford, Christopher; Guler, Emre; Fugal, Mario; Irvin, Bradley

    2013-10-01

    Precision low energy neutron experiments require extremely uniform magnetic fields for manipulating the neutron spin. Such fields can be generated with surface current coils-precision 3-dimensional printed circuits. We are developing a facility to etch out these circuits on copper-plated curved forms using a high-speed spindle attached to the end-effector of a Staubli RX130 six-axis robotic arm. We describe our mathematical model of the robotic links and the software system we designed to control the motion of the arm and to prevent collisions during actuations. We developed a calibration procedure to achieve accuracy of 30 microns in the position of drill.

  6. Application field and ways to control alternating-current plasma torch with rail electrodes

    Science.gov (United States)

    Kuznetsov, V. E.; Safronov, A. A.; Vasilieva, O. B.; Shiryaev, V. N.; Dudnik, Yu D.; Pavlov, A. V.; Kuchina, Yu A.

    2018-01-01

    The paper deals with the investigation of parameters of the high voltage alternating-current plasma torch with rail electrodes. Usage of the injector and its variation allows controlling of operation of the ac plasma torch with rail electrodes. Also the possibility to protect the electric arc chamber without protective gas has been studied. It was found that increasing in the injector power causes the repeated breakdown at lower voltage and hence the arc dimensions decreases. The results of experiments are presented in the paper.

  7. Comparison of Current Control Methods on Carrier Based VSI-PWM Inverter Drives From Line Power Quality Aspect

    Directory of Open Access Journals (Sweden)

    Muh. Imran Hamid

    2008-08-01

    Full Text Available This paper describes simulation result of two methods in current controlling for carrier based VSI-PWM inverter: hysteresis and ramp comparison control. The simulation is useful in selection of ASDs and generally–converter, from power quality point of view. Simulation results show that both ramp comparison and hysteresis control methods gives difference characteristic on line voltage and line current. A ramp comparison method is better in form of lower effect on line current distortion compare with hysteresis control method. Meanwhile, for line voltage distortion, hysteresis control seen better.

  8. Current status and Future Works in Dynamic Control Rod Worth Measurement Method in KOREA

    International Nuclear Information System (INIS)

    Lee, Eun-ki; Shin, Ho-chul

    2015-01-01

    Actually all ex-core detector signal data processing and extracting the final conclusion about the single control bank was performed by the 3rd generation of Digital Reactivity Computer System (DRCS). From 2006 to 2016, about 250 control bank worths were measured and the difference between measured and calculated worth of individual bank were several % and total rod worth differences of each cycle were less than 3%. However there were a few odd cases showing the individual difference greater than 15% which is the criteria. And some OPR1000 nuclear power plants built recently use fission chambers instead of traditional uncompensated ion chambers. To consider those conditions, any modification of the DCRM method and DRCS were requested. In this paper, short description about DCRM method, current status of DCRM modification and future works are discussed. About 10 cases among about 250 control bank worth measurement with original DCRM method with UIC signals result in very heavy fluctuation on reactivity curve and the difference approaches 15%, the individual limit. The electrometer signals processing method were the main cause. To overcome this problem, a modified reactivity computer system using own current treatment logic was designed. It shows the reactivity fluctuation can be reduced dramatically in case of UIC signal. Recently the modified DRCS coupled INVESE code applied Westinghouse 2 Loop plant and gave very good results except a control bank whose measured rod worth was shown of 18% difference from the estimated value. The results were same for three repeat tests. All possible causes are examined from computer codes to detail data acquisition system

  9. A review of current strategy for rabies prevention and control in the developing world

    Directory of Open Access Journals (Sweden)

    Suneela Garg

    2017-03-01

    Full Text Available The control of Rabies, a zoonotic viral disease is a major public challenge in several developing countries. Current approaches for rabies control are overwhelmingly directed towards provision of effective post exposure prophylaxis (PEP to animal bite victims. The enormous costs involved in rabies prophylaxis is an important factor precluding its universal application in all animal bite victims especially in those residing in resource constrained settings. The intradermal route of administration has been shown to be cost effective except in peripheral regions with fewer animal bite cases. Nevertheless, rabies control program with their expected emphasis on human rabies prophylaxis have neglected canine vaccination. The feasibility of canine rabies vaccination depends primarily upon allocation of resources through political commitment and effective public private partnerships. However, in large parts of the world including India formal dog ownership constitutes a small minority of the overall canine population while state funded canine vaccination drives often fail to impress policy makers who struggle to maintain budgets for adequate coverage of rabies PEP for animal bite victims. The key to rabies control may therefore rest upon a one health approach with development of newer vaccine technology which is cost effective for vaccination in both, man and animal.

  10. Transcranial direct current stimulation in post-stroke dysphagia: a systematic review of randomized controlled trials

    Directory of Open Access Journals (Sweden)

    Kavian Ghandehari

    2016-07-01

    Full Text Available Introduction: The aim of this research was to systematically review all the randomized controlled trials that have evaluated the effect of transcranial direct current stimulation (tDCS on post-stroke dysphagia. Methods: Three electronic databases were searched for relevant articles that were uploaded from their inception to March 2015: PubMed, Cochrane Library (Cochrane Central Register of Controlled Trials, and Scopus. All data was that was related to the location of the cerebrovascular accident (CVA, the parameters of tDCS, post-stroke time to commencement of tDCS, the stimulated hemisphere, stimulation dose, any outcome measurements, and follow-up duration were extracted and assessed. Finally, a number of observations were generated through a qualitative synthesis of the extracted data.Result: Three eligible randomized controlled trials were included in the systematic review. All three trials reported that, in comparison to a placebo, tDCS had a statistically significant effect on post-stroke dysphagia.Discussion: The results of our systematic review suggest that tDCS may represent a promising novel treatment for post-stroke dysphagia. However, to date, little is known about the optimal parameters of tDCS for relieving post-stroke dysphagia. Further studies are warranted to refine this promising intervention by exploring the optimal parameters of tDCS.Conclusion: Since brainstem swallowing centers have bilateral cortical innervations, measures that enhance cortical input and sensorimotor control of brainstem swallowing may facilitate recovery from dysphagia.

  11. Control of zoonoses in emergency situations: lessons learned during recent outbreaks (gaps and weaknesses of current zoonoses control programmes

    Directory of Open Access Journals (Sweden)

    Darem Tabbaa

    2008-12-01

    Full Text Available In emergency situations, domestic animals and wildlife are, like people, exposed to infectious diseases and environmental contaminants in the air, soil, water and food. They can suffer from acute and/or chronic diseases from such exposure. Often animals serve as disease reservoirs or early warning systems for the community in regard to the spread of zoonotic diseases. Over 100 years of experience have shown that animal and human health are closely related. During the past few years, emergent disease episodes have increased; nearly all have involved zoonotic agents. As there is no way to predict when or where the next important new zoonotic pathogen will emerge or what its ultimate importance might be, investigation at the first sign of emergence of a new zoonotic disease is particularly important. Today, in many emerging situations, different activities involving zoonotic disease control are at risk because of failed investigative infrastructures or financial constraints. Considering that zoonotic diseases have their own characteristics, their prevention and control require unique strategies, based more on fundamental and applied research than on traditional approaches. Such strategies require cooperation and coordination between animal and public health sectors and the involvement of other disciplines and experts such as epidemiologists, entomologists, environmentalists and climatologists. Lessons learned from the avian influenza pandemic threat, the Crimean-Congo haemorrhagic fever and rabies outbreaks are presented and the gaps and weakness of current control programmes are discussed.

  12. Method for Estimating Maximum Torque Control Axis of Interior Permanent Magnet Synchronous Motors for an Arbitrary Current Vector

    Science.gov (United States)

    Tomigashi, Yoshio; Ueyama, Kenji

    A method for directly estimating the axis corresponding to the current phase in maximum torque per ampere (MTPA) control is proposed for sensorless vector control. This axis is called the maximum torque control (MTC) axis. In past studies concerning such methods, the behavior of the axis has been considered only for the case of MTPA control and not for an arbitrary current vector (with flux weakening control) that has a phase different from that for MTPA control. This paper enhances the definition of the MTC axis for an arbitrary current vector, describes an extended EMF model based on the MTC axis, and presents a method that can directly estimate the axis for an arbitrary current vector with flux weakening control. The effectiveness of the proposed method is confirmed by numerical analysis results.

  13. Operational Experience and Consolidations for the Current Lead Control Valves of the Large Hadron Collider

    CERN Document Server

    Perin, A; Pirotte, O; Krieger, B; Widmer, A

    2012-01-01

    The Large Hadron Collider superconducting magnets are powered by more than 1400 gas cooled current leads ranging from 120 A to 13000 A. The gas flow required by the leads is controlled by solenoid proportional valves with dimensions from DN 1.8 mm to DN 10 mm. During the first months of operation, signs of premature wear were found in the active parts of the valves. This created major problems for the functioning of the current leads threatening the availability of the LHC. Following the detection of the problems, a series of measures were implemented to keep the LHC running, to launch a development program to solve the premature wear problem and to prepare for a global consolidation of the gas flow control system. This article describes first the difficulties encountered and the measures taken to ensure a continuous operation of the LHC during the first year of operation. The development of new friction free valves is then presented along with the consolidation program and the test equipment developed to val...

  14. Power grid current harmonics mitigation drawn on low voltage rated switching devices with effortless control

    Energy Technology Data Exchange (ETDEWEB)

    Marques, Hugo S.; Anunciada, Victor; Borges, Beatriz V. [Power Electronics Group, Instituto de Telecomunicacoes, Lisbon (Portugal); Instituto Superior Tecnico - Universidade Tecnica de Lisboa, Lisbon (Portugal)

    2010-01-15

    The great majority of the existing hybrid active power filter solutions is normally focused in 3{phi} systems and, in general, concentrates its domain of application in specific loads with deterministic behavior. Because common use grids do not exhibit these characteristics, it is mandatory to develop solutions for more generic scenarios, encouraging the use of less classical hybrid solutions. In fact, due to the widely use of switch mode converters in a great variety of consumer electronics, the problematic of mains current harmonic mitigation is no longer an exclusive matter of 3{phi} systems. The contribution of this paper is to present a shunt hybrid active power filter topology, initially conceived to work in 1{phi} domestic grids, able to operate the inverter at a voltage rate that can be lower than 10% of the mains voltage magnitude, even under nonspecific working conditions. In addition, the results shown in this paper demonstrate that this topology can, without lack of generality, be suitable to medium voltage (1{phi} or 3{phi}) systems. A new control approach for the proposed topology is discussed in this paper. The control method exhibits an extremely simple architecture requiring single point current sensing only, with no need for any kind of reference. Its practical implementation can be fulfilled by using very few, common use, operational amplifiers. The principle of operation, design criteria, simulation predictions and experimental results are presented and discussed. (author)

  15. Characteristics of the Current-Controlled Phase Transition of VO2 Microwires for Hybrid Optoelectronic Devices

    Directory of Open Access Journals (Sweden)

    Arash Joushaghani

    2015-08-01

    Full Text Available The optical and electrical characteristics of the insulator-metal phase transition of vanadium dioxide (VO2 enable the realization of power-efficient, miniaturized hybrid optoelectronic devices. This work studies the current-controlled, two-step insulator-metal phase transition of VO2 in varying microwire geometries. Geometry-dependent scaling trends extracted from current-voltage measurements show that the first step induced by carrier injection is delocalized over the microwire, while the second, thermally-induced step is localized to a filament about 1 to 2 μm wide for 100 nm-thick sputtered VO2 films on SiO2. These effects are confirmed by direct infrared imaging, which also measures the change in optical absorption in the two steps. The difference between the threshold currents of the two steps increases as the microwires are narrowed. Micron- and sub-micron-wide VO2 structures can be used to separate the two phase transition steps in photonic and electronic devices.

  16. Monochromator for synchrotron light with temperature controlled by electrical current on silicon crystal

    International Nuclear Information System (INIS)

    Cusatis, Cesar; Souza, Paulo E.N.; Gobbi, Angelo; Carvalho Junior, Wilson de

    2011-01-01

    Full text. doped silicon crystal was used simultaneously as a monochromator, sensor and actuator in such way that its temperature could be controlled. Ohmic contacts allowed resistance measurements on a perfect silicon crystal, which were correlated to its temperature. Using the ohmic contacts, an electrical current caused Joule heating on the monochromator that was used to control its temperature. A simple stand-alone electronic box controlled the system. The device was built and tested with white beam synchrotron light on the double crystal monochromator of the XRD line of LNLS, Laboratorio Nacional de Luz Sincrotron, Campinas. The first crystal of a double crystal monochromator determines the energy that is delivered to a synchrotron experimental station and its temperature instability is a major source of energy and intensity instability. If the (333) silicon monochromator is at theta Bragg near 45 degree the variation of the diffraction angle is around one second of arc per degree Kelvin. It may take several minutes for the first crystal temperature to stabilize at the beginning of the station operation when the crystal and its environment are cold. With water refrigeration, the average overall temperature of the crystal may be constant, but the temperature of the surface changes with and without the white beam. The time used to wait for stabilization of the beam energy/intensity is lost unless the temperature of the crystal surface is kept constant. One solution for keeping the temperature of the monochromator and its environment constant or nearly constant is Joule heating it with a controlled small electrical current flowing on the surface of a doped perfect crystal. When the white beam is on, this small amount of extra power will be more concentrated at the beam footpath because the resistance is lower in this region due to the higher temperature. In addition, if the crystal itself is used to detect the temperature variation by measuring the electrical

  17. A robust grid current controller with grid harmonic and filter resonance damping capabilities using a closed-loop admittance shaping

    DEFF Research Database (Denmark)

    Pérez, Jorge; Cóbreces, Santiago; Wang, Xiongfei

    2017-01-01

    This paper presents a grid current control of a grid connected Voltage Source Converter (VSC) with an LCL filter. The control method enables to shape the input admittance of the converter in addition to track a given current reference. By specifying a low resistive admittance profile, a suitable ...

  18. Adaptive Hybrid Fuzzy-Proportional Plus Crisp-Integral Current Control Algorithm for Shunt Active Power Filter Operation

    Directory of Open Access Journals (Sweden)

    Nor Farahaida Abdul Rahman

    2016-09-01

    Full Text Available An adaptive hybrid fuzzy-proportional plus crisp-integral current control algorithm (CCA for regulating supply current and enhancing the operation of a shunt active power filter (SAPF is presented. It introduces a unique integration of fuzzy-proportional (Fuzzy-P and crisp-integral (Crisp-I current controllers. The Fuzzy-P current controller is developed to perform gain tuning procedure and proportional control action. This controller inherits the simplest configuration; it is constructed using a single-input single-output fuzzy rule configuration. Thus, an execution of few fuzzy rules is sufficient for the controller’s operation. Furthermore, the fuzzy rule is developed using the relationship of currents only. Hence, it simplifies the controller development. Meanwhile, the Crisp-I current controller is developed to perform integral control action using a controllable gain value; to improve the steady-state control mechanism. The gain value is modified and controlled using the Fuzzy-P current controller’s output variable. Therefore, the gain value will continuously be adjusted at every sample period (or throughout the SAPF operation. The effectiveness of the proposed CCA in regulating supply current is validated in both simulation and experimental work. All results have proven that the SAPF using the proposed CCA is capable to regulate supply current during steady-state and dynamic-state operations. At the same time, the SAPF is able to enhance its operation in compensating harmonic currents and reactive power. Furthermore, the implementation of the proposed CCA has resulted more stable dc-link voltage waveform.

  19. The Current State of Poison Control Centers in Pakistan and the Need for Capacity Building

    Directory of Open Access Journals (Sweden)

    Nadeem Khan

    2014-03-01

    Full Text Available Background: Chemical exposure is a major health problem globally. Poison control centers (PCCs play a leading role both in developed and developing countries in the prevention and control of poisonous chemical exposures. In this study, we aimed to assess the current state of PCCs in Pakistan and highlight capacity building needs in these centers. Methods: A cross-sectional survey of the two registered PCCs was done during August – December 2011. Necessary services of the PCCs were evaluated and the data were recorded on a predesigned checklist. Results: Both PCCs are affiliated to a tertiary care hospital. Clinical services to poisoned patients were available 24 hours a day / 7 days a week. Information on common local products was available to poison center staff. Both centers were involved in undergraduate and post graduate teaching. Telephone poison information service was not available in either of centers. There was a limited capacity for qualitative and analytical toxicology. Common antidotes were available. There were limited surveillance activities to capture toxic risks existing in the community and also a deficiency was observed in chemical disaster planning. Conclusion: PCCs in Pakistan need capacity building for specialized training in toxicology, toxicovigilance, chemical disaster planning, analytical laboratory tests and telephone service for consultation in poisoning cases.   How to cite this article: Khan NU, Mir MU, Khan UR, Khan AR, Ara J, Raja K, et al. The Current State of Poison Control Centers in Pakistan and the Need for Capacity Building. Asia Pac J Med Toxicol 2014;3:31-5.

  20. Electrodermal activity at acupuncture points differentiates patients with current pain from pain-free controls.

    Science.gov (United States)

    Turner, Linda; Linden, Wolfgang; Marshall, Candace

    2013-03-01

    This study evaluated whether electrodermal resistance at acupuncture points (AP) systematically varies as a function of pain. The study was conceived as a proof-of-principle study in support of research on acupuncture and other complementary medicine approaches. Specifically, this study investigates whether or not electrodermal activity systematically differentiates arthritis patients with current pain from pain-free controls. Participants with rheumatoid arthritis (n = 32) and a typical pain level of at least 3 (on a 0-10 scale) were compared with case controls (n = 28) who had no medical diagnosis and were pain free. Electrodermal resistance at AP was measured with a commercial ohmmeter and compared to heart rate, blood pressure, and ratings on the Pain Catastrophization Scale and the McGill Melzack Pain Questionnaire. There were consistent differences between the experimental group and the control group on all markers of pain. Similarly, there were significant group differences and some trends for electrodermal activity at the AP labeled 'bladder,' 'gall bladder,' and 'small intestine.' It is concluded that the concept of electrodermal resistance at AP possesses criterion validity for distinguishing pain from a no pain state. This research provides support for the usefulness of measuring electrodermal activity when testing energy-based models of disease, and can be seen as a bridge between Western and Chinese medicine.

  1. Cerebellar Transcranial Direct Current Stimulation (ctDCS) Impairs Balance Control in Healthy Individuals.

    Science.gov (United States)

    Foerster, Águida; Melo, Lorena; Mello, Marina; Castro, Rebeca; Shirahige, Lívia; Rocha, Sérgio; Monte-Silva, Kátia

    2017-08-01

    The cerebellum plays an important role in the planning, initiation and stability of movements, as well as in postural control and balance. Modulation of neural regions underlying balance control may be a potential alternative to treat balance impairments in cerebellar patients. Transcranial direct current stimulation (tDCS) is a noninvasive and safe tool capable to modulate cerebellar activity. We aim to investigate the effects of cerebellar tDCS (ctDCS) on postural balance in healthy individuals. Fifteen healthy and right-handed subjects were submitted to three sessions of ctDCS (anodal, cathodal and sham), separated by at least 48 h. In each session, tests of static (right and left Athlete Single Leg tests) and dynamic balance (Limits of Stability test) were performed using the Biodex Balance System before and immediately after the ctDCS. The results revealed that cathodal ctDCS impaired static balance of healthy individuals, reflected in higher scores on overall stability index when compared to baseline for right (p = 0.034) and left (p = 0.01) Athlete Single Leg test. In addition, we found significant impairment for left Athlete Single Leg test in comparison to sham stimulation (p = 0.04). As far as we know, this is the first study that points changes on balance control after ctDCS in healthy individuals. This finding raises insights to further investigation about cerebellar modulation for neurological patients.

  2. Generalized stability regions of current control for LCL-filtered grid-connected converters without passive or active damping

    DEFF Research Database (Denmark)

    Tang, Yi; Yoon, Changwoo; Zhu, Rongwu

    2015-01-01

    This paper investigates the stability regions of current control for LCL-filtered grid-connected converters, where no active or passive damping is required to stabilize the closed-loop control system. It is already identified in the literature that if the LCL resonance frequency is placed within 1...... the resonance frequency could be larger than 1/2 of the sampling frequency, and derives the complete stability regions for both grid and converter current control. Interestingly, it is found that for any given LCL-filter design, there will always be one stable current control design without any damping, which...... may greatly facilitate the system controller design. Two design examples are given to demonstrate the feasibility and effectiveness of the proposed LCL-filter and current controller design. These theoretical analyses are also supported with simulation and experimental results....

  3. DC-Voltage Fluctuation Elimination Through a DC-Capacitor Current Control for DFIG Converters Under Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Liu, Changjin; Xu, Dehong; Zhu, Nan

    2013-01-01

    Unbalanced grid voltage causes a large second-order harmonic current in the dc-link capacitors as well as dc-voltage fluctuation, which potentially will degrade the lifespan and reliability of the capacitors in voltage source converters. This paper proposes a novel dc-capacitor current control me...... grid voltage conditions. A modular implementation method of the proposed control strategy is developed for the DFIG controller. Finally, experiments are presented to validate the theoretical analysis....

  4. Recent Improvements to the Control of the CTF3 High-Current Drive Beam

    CERN Document Server

    Constance, B; Gamba, D; Skowronski, P K

    2013-01-01

    In order to demonstrate the feasibility of the CLIC multiTeV linear collider option, the drive beam complex at the CLIC Test Facility (CTF3) at CERN is providing highcurrent electron pulses for a number of related experiments. By means of a system of electron pulse compression and bunch frequency multiplication, a fully loaded, 120 MeV linac is used to generate 140 ns electron pulses of around 28 Amperes. Subsequent deceleration of this high-current drive beam demonstrates principles behind the CLIC acceleration scheme, and produces 12 GHz RF power for experimental purposes. As the facility has progressed toward routine operation, a number of studies aimed at improving the drive beam performance have been carried out. Additional feedbacks, automated steering programs, and improved control of optics and dispersion have contributed to a more stable, reproducible drive beam with consequent benefits for the experiments.

  5. Hysteresis current control technique of VSI for compensation of grid-connected unbalanced loads

    DEFF Research Database (Denmark)

    Pouresmaeil, Edris; Akorede, Mudathir Funsho; Montesinos-Miracle, Daniel

    2014-01-01

    interconnection issues that usually arise as DG units connect to the electric grid. The proposed strategy, implemented in Matlab/Simulink environment in different operating scenarios, provides compensation for active, reactive, unbalanced, and harmonic current components of grid-connected nonlinear unbalanced......The global trends nowadays in the power generation industry are to supplement the electricity production using distributed generation (DG) technologies based on renewable energy resources such as photovoltaic, wind power, etc. However, failure to properly control the operation of distributed energy...... resources as they connect to the exiting power grid could provoke many power quality problems on the grid side. For this reason, due considerations must be given to power generation and safe running before DG units is actually integrated into the power grid. The main aim of this paper is to address the grid...

  6. Analysis of Three-Phase Rectifier Systems with Controlled DC-Link Current Under Unbalanced Grids

    DEFF Research Database (Denmark)

    Kumar, Dinesh; Davari, Pooya; Zare, Firuz

    2017-01-01

    Voltage unbalance is the most common disturbance in distribution networks, which give undesirable effects on many grid connected power electronics systems including Adjustable Speed Drive (ASD). Severe voltage unbalance can force three-phase rectifiers into almost single-phase operation, which...... degrades the grid power quality and also imposes a significant negative impact on the ASD system. This major power quality issue affecting the conventional rectifiers can be attenuated by controlling the DC-link current based on an Electronic Inductor (EI) technique. The purpose of this digest...... is to analyze and compare the performance of an EI with a conventional three-phase rectifier under unbalanced grid conditions. Experimental and simulation results validate the proposed mathematical modelling. Further analysis and benchmarking will be provided in the final paper....

  7. Estimation of the Plant Time Constant of Current-Controlled Voltage Source Converters

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Malvar, Jano

    2014-01-01

    of the VSC interface filter measured at rated conditions. This paper extends that method so that both parameters of the plant time constant (resistance and inductance) are estimated. Such enhancement is achieved through the evaluation of the closed-loop transient responses of both axes of the synchronous......Precise knowledge of the plant time constant is essential to perform a thorough analysis of the current control loop in voltage source converters (VSCs). As the loop behavior can be significantly influenced by the VSC working conditions, the effects associated to converter losses should be included...... in the model, through an equivalent series resistance. In a recent work, an algorithm to identify this parameter was developed, considering the inductance value as known and practically constant. Nevertheless, the plant inductance can also present important uncertainties with respect to the inductance...

  8. Optical switching of electric charge transfer pathways in porphyrin: a light-controlled nanoscale current router.

    Science.gov (United States)

    Thanopulos, Ioannis; Paspalakis, Emmanuel; Yannopapas, Vassilios

    2008-11-05

    We introduce a novel molecular junction based on a thiol-functionalized porphyrin derivative with two almost energetically degenerate equilibrium configurations. We show that each equilibrium structure defines a pathway of maximal electric charge transfer through the molecular junction and that these two conduction pathways are spatially orthogonal. We further demonstrate computationally how to switch between the two equilibrium structures of the compound by coherent light. The optical switching mechanism is presented in the relevant configuration subspace of the compound, and the corresponding potential and electric dipole surfaces are obtained by ab initio methods. The laser-induced isomerization takes place in two steps in tandem, while each step is induced by a two-photon process. The effect of metallic electrodes on the electromagnetic irradiation driving the optical switching is also investigated. Our study demonstrates the potential for using thiol-functionalized porphyrin derivatives for the development of a light-controlled nanoscale current router.

  9. Brucellosis in Sub-Saharan Africa: Current challenges for management, diagnosis and control.

    Science.gov (United States)

    Ducrotoy, M; Bertu, W J; Matope, G; Cadmus, S; Conde-Álvarez, R; Gusi, A M; Welburn, S; Ocholi, R; Blasco, J M; Moriyón, I

    2017-01-01

    Brucellosis is a highly contagious zoonosis caused by bacteria of the genus Brucella and affecting domestic and wild mammals. In this paper, the bacteriological and serological evidence of brucellosis in Sub-Saharan Africa (SSA) and its epidemiological characteristics are discussed. The tools available for the diagnosis and treatment of human brucellosis and for the diagnosis and control of animal brucellosis and their applicability in the context of SSA are presented and gaps identified. These gaps concern mostly the need for simpler and more affordable antimicrobial treatments against human brucellosis, the development of a B. melitensis vaccine that could circumvent the drawbacks of the currently available Rev 1 vaccine, and the investigation of serological diagnostic tests for camel brucellosis and wildlife. Strategies for the implementation of animal vaccination are also discussed. Copyright © 2015 The Authors. Published by Elsevier B.V. All rights reserved.

  10. Topographic control on pyroclastic density currents: the example of Mount St. Helens 1980 blast

    Science.gov (United States)

    Esposti Ongaro, T.; Clarke, A. B.; Voight, B.; Neri, A.; Widiwijayanti, C.

    2012-04-01

    Volcanic lateral blasts are among the most spectacular and devastating of natural phenomena, characterized by the violent release of a relatively low mass of magma producing a remarkably broad area of significant damage. The most known volcanic blast at Mount Saint Helens, on 18 May 1980, devastated an area of 600 squared km in about five minutes, being able to override topographic obstacles of several hundreds of metres. By means of 3D multiphase numerical simulations we demonstrate that Mount St. Helens blast was generated by the rapid expansion (burst) of a pressurized polydisperse mixture of gas and particles and its subsequent gravitational collapse and that the observed front propagation, final runout and damage can be explained by the emplacement of an unsteady, stratified pyroclastic density current (PDC), controlled by gravity and terrain morphology. Numerical results are able to describe the non-equilibrium sedimentation dynamics of volcanic particles during PDC propagation across the rugged topography characterizing the area devastated by the blast. In valleys and topographic lows, pyroclasts accumulate progressively at the base of the flow, after the passage of the flow head, forming a dense basal flow depleted in fines. Blocking and channelling of such basal flow by topographic ridges provides the mechanism for progressive current unloading. On ridges, sedimentation occurs from the upper, dilute wake region, which follows the current head. Although the model formulation and the vertical numerical resolution do not yet allow the direct simulation of the deposit consolidation, present results provide a consistent, quantitative model able to interpret the observed stratigraphic sequence.

  11. Modelling rogue waves through exact dynamical lump soliton controlled by ocean currents

    Science.gov (United States)

    Kundu, Anjan; Mukherjee, Abhik; Naskar, Tapan

    2014-01-01

    Rogue waves are extraordinarily high and steep isolated waves, which appear suddenly in a calm sea and disappear equally fast. However, though the rogue waves are localized surface waves, their theoretical models and experimental observations are available mostly in one dimension, with the majority of them admitting only limited and fixed amplitude and modular inclination of the wave. We propose two dimensions, exactly solvable nonlinear Schrödinger (NLS) equation derivable from the basic hydrodynamic equations and endowed with integrable structures. The proposed two-dimensional equation exhibits modulation instability and frequency correction induced by the nonlinear effect, with a directional preference, all of which can be determined through precise analytic result. The two-dimensional NLS equation allows also an exact lump soliton which can model a full-grown surface rogue wave with adjustable height and modular inclination. The lump soliton under the influence of an ocean current appears and disappears preceded by a hole state, with its dynamics controlled by the current term. These desirable properties make our exact model promising for describing ocean rogue waves. PMID:24711719

  12. Analysis and Design of Improved Weighted Average Current Control Strategy for LCL-Type Grid-Connected Inverters

    DEFF Research Database (Denmark)

    Han, Yang; Li, Zipeng; Yang, Ping

    2017-01-01

    characteristics under weak grid scenarios. To overcome this shortcoming, the improved WAC damping method is proposed with an additional capacitor current feedback loop. In this paper, a systematic parameter design guideline for the optimal selection of the current loop PR controller and the additional capacitor...... current plus capacitor current feedback system is widely used for its better transient response and high robustness against the grid impedance variations. While the weighted average current (WAC) feedback scheme is capable to provide a wider bandwidth at higher frequencies but show poor stability...... grid scenarios, and the stability and robustness have been enhanced under control delay. Finally, the experimental results are presented to validate the effectiveness of the proposed improved WAC control strategy and the parameter design method. Analysis and Design of Improved Weighted Average Current...

  13. 78 FR 64425 - Current Good Manufacturing Practice and Hazard Analysis and Risk-Based Preventive Controls for...

    Science.gov (United States)

    2013-10-29

    ... Risk- Based Preventive Controls for Food for Animals; Public Meeting on Proposed Rule AGENCY: Food and... requirements for current good manufacturing practice and hazard analysis and risk-based preventive controls for... regulations requiring preventive controls for human food and animal food, set standards for produce safety...

  14. A Technique to Estimate the Equivalent Loss Resistance of Grid-Tied Converters for Current Control Analysis and Design

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Fernandez, Francisco Daniel Freijedo

    2015-01-01

    by means of an equivalent series resistance. This paper proposes a method to identify the VSC equivalent loss resistance for the proper tuning of the current control loop. It is based on analysis of the closed-loop transient response provided by a synchronous proportional-integral current controller......, according to the internal model principle. The method gives a set of loss resistance values linked to working conditions, which can be used to improve the tuning of the current controllers, either by online adaptation of the controller gains or by open-loop adaptive adjustment of them according to prestored......Rigorous analysis and design of the current control loop in voltage source converters (VSCs) requires an accurate modeling. The loop behavior can be significantly influenced by the VSC working conditions. To consider such effect, converter losses should be included in the model, which can be done...

  15. A Comprehensive Analysis of Multiscale Field-Aligned Currents: Characteristics, Controlling Parameters, and Relationships

    Science.gov (United States)

    McGranaghan, Ryan M.; Mannucci, Anthony J.; Forsyth, Colin

    2017-12-01

    We explore the characteristics, controlling parameters, and relationships of multiscale field-aligned currents (FACs) using a rigorous, comprehensive, and cross-platform analysis. Our unique approach combines FAC data from the Swarm satellites and the Advanced Magnetosphere and Planetary Electrodynamics Response Experiment (AMPERE) to create a database of small-scale (˜10-150 km, 250 km) FACs. We examine these data for the repeatable behavior of FACs across scales (i.e., the characteristics), the dependence on the interplanetary magnetic field orientation, and the degree to which each scale "departs" from nominal large-scale specification. We retrieve new information by utilizing magnetic latitude and local time dependence, correlation analyses, and quantification of the departure of smaller from larger scales. We find that (1) FACs characteristics and dependence on controlling parameters do not map between scales in a straight forward manner, (2) relationships between FAC scales exhibit local time dependence, and (3) the dayside high-latitude region is characterized by remarkably distinct FAC behavior when analyzed at different scales, and the locations of distinction correspond to "anomalous" ionosphere-thermosphere behavior. Comparing with nominal large-scale FACs, we find that differences are characterized by a horseshoe shape, maximizing across dayside local times, and that difference magnitudes increase when smaller-scale observed FACs are considered. We suggest that both new physics and increased resolution of models are required to address the multiscale complexities. We include a summary table of our findings to provide a quick reference for differences between multiscale FACs.

  16. Current Limitations in the Control and Spread of Ticks that Affect Livestock: A Review

    Directory of Open Access Journals (Sweden)

    Agustín Estrada-Peña

    2013-04-01

    Full Text Available Ticks are well-known parasites that affect livestock productivity. This paper reviews the current knowledge regarding the spread of ticks with their impact in animal health and the limitations to achieve effective control measures. The forecasted trends in climate play an obvious role in promoting the spread of ticks in several regions. It appears that climate warming is pivotal in the spread and colonization of new territories by Rhipicephalus microplus in several regions of Africa. The reported increase in altitude of this tick species in the mountainous regions of Central and South America appears to be driven by such general trends in climate change. This factor, however, is not the only single contributor to the spread of ticks. The poor management of farms, uncontrolled movements of domestic animals, abundance of wild animals, and absence of an adequate framework to capture the ecological plasticity of certain ticks may explain the complexity of the control measures. In this paper, we review several details regarding the relationships of ticks with the environment, wild fauna and competition with other species of ticks. Our intention is to highlight these relationships with the aim to produce a coherent framework to explore tick ecology and its relationship with animal production systems.

  17. Current Status of Air Toxics Management and Its Strategies for Controlling Emissions in Taiwan.

    Science.gov (United States)

    Tsai, Wen-Tien

    2016-04-12

    Since the 1970s, hazardous air pollutants (HAPs), so-called air toxics, have been of great concern because they can cause serious human health effects and have adverse effects on the environment. More noticeably, some of them are known to be human carcinogens. The objective of this paper is to investigate the regulatory systems and human health effects of air toxics which have been designated by the Taiwan government under the Air Pollution Control Act. These toxic air pollutants include acutely toxic gas ( i.e ., ammonia, chlorine, fluorides, hydrochloric acid, hydrogen cyanide, hydrogen sulfide, nitric acid, phosphoric acid and sulfuric acid), gas containing heavy metals, and carcinogenic chemicals (including formaldehyde, vinyl chloride, asbestos and matter containing asbestos, dioxins and furans, volatile organic compounds, polycyclic aromatic hydrocarbons, and polychlorinated biphenyls). In line with international concern about the carcinogenic risk and environmental persistence of polychlorinated dibenzo- p -dioxins and polychlorinated dibenzofurans (PCDDs/PCDFs) and heavy metals in recent years, the current status in monitoring and reducing the emissions of PCDDs/PCDFs from stationary sources was analyzed as a case study in the present study. Furthermore, the control strategies for reducing emissions of air toxics from stationary sources in Taiwan were also addressed.

  18. Current and advanced NO/sub x/-control technology for coal-fired industrial boilers

    Energy Technology Data Exchange (ETDEWEB)

    1978-12-01

    A NOx-control-technology assessment study of coal-fired industrial boilers was conducted to examine the effectiveness of combustion-modification methods, including low excess air, staged combustion, and burner modifications. Boiler types considered included overfed and underfed stokers, spreader stokers, pulverized-coal and coal-fired cyclone units. Significant variations in NOx emissions occur with boiler type, firing method, and coal type; a relative comparison of emission-control performance, cost, and operational considerations is presented for each method. Baseline (as-found) emissions from grate-fired stokers were shown to be in the range of 200 to 300 ppM. Similarly, as-found emissions from suspension-fired units were quite low (350 to 600 ppM) as compared to comparably designed utility-sized units. Low excess air was shown to be the most effective method on existing units, reducing emissions by approximately 10%. Evaluation of staged combustion and burner modification, however, were limited due to current boiler designs. Major hardware modification/design and implementation are necessary before the potential of these techniques can be fully evaluated. The study emphasized the numerous operational factors that are of major importance to the user in selecting and implementing a combustion-modification program, including energy considerations, incremental capital and operating costs, corrosion, secondary pollutants, and retrofit potential.

  19. Finite Control Set–Model Predictive Control with Modulation to Mitigate Harmonic Component in Output Current for a Grid-Connected Inverter under Distorted Grid Conditions

    OpenAIRE

    Tien Hai Nguyen; Kyeong-Hwa Kim

    2017-01-01

    This paper presents an improved current control strategy for a three-phase grid-connected inverter under distorted grid conditions. In terms of performance, it is important for a grid-connected inverter to maintain the harmonic contents of inverter output currents below the specified limit even when the grid is subject to harmonic distortion. To address this problem, this paper proposes a modulated finite control set–model predictive control (FCS-MPC) scheme, which effectively mitigates the h...

  20. Proposed Designs for a Gate-Controlled Lateral Current Injection Laser

    Science.gov (United States)

    Honey, David Alan

    High speed communications systems have experienced rapid growth due to the development of high performance photonic components. Hardware such as fiberoptics and semiconductor lasers have not only increased the data handling capabilities of these systems, they have also reduced the cost of owning and operating them. Improving the data transmission capabilities of the currently installed fiberoptic infrastructure is an important means of economically enhancing our communications capabilities. However, high speed optical data transmitters are a serious obstacle to future improvements in these systems. The high speed performance of direct modulation lasers lags far behind the present day capabilities of fiber and optical detectors. Gain compression and heating are the dominant phenomena keeping direct modulation lasers from achieving their predicted level of performance. Gate Controlled Lateral Current Injection (GCLCI) lasers use the field-effect of a transistors' gate to modulate a semiconductor laser. Our goal in this dissertation is to propose GCLCI laser designs and fabrication methods. The GCLCI laser combines the structure of a lateral current injection (LCI) laser with the gate of a modulation doped field effect transistor (MODFET). There are many published models predicting the performance of the GCLCI laser. While all of these models have some basis in experimentally observed effects, none have resulted in a working GCLCI laser. We present an investigation of the critical issues surrounding GCLCI design and fabrication. We give an analysis of the tradeoffs between the MODFET's and the laser's conflicting gate-to-channel separation requirements. The MODFET needs to have the gate close to the quantum well in order to permit high speed modulation of current flow. The laser needs a thick layer on top of the quantum well active region in order to have adequate optical confinement. Our fabrication efforts failed to produce a working GCLCI laser. We did however get

  1. Foot-and-mouth disease control in Zambia: A review of the current situation

    Directory of Open Access Journals (Sweden)

    Yona Sinkala

    2012-06-01

    . Presented with the current poverty levels failure to institute result oriented control measures will exacerbate the already life-threatening situation.

  2. Control of the dielectric microrods rotation in liquid by alternating current electric field

    Science.gov (United States)

    Ren, Yukun; Li, Bin; Jiang, Hongyuan

    2014-05-01

    Microfluidics is a promising system for the manipulation of micro-nano particles and fluids. In this platform, alternating current (AC) electric field is usual an effective tool for the general particles control. However, traditional work paid more attention on the regular spherical particles with no obvious distinction when rotating, resulting in imprecise rotation speed calculation. In essence, non-spherical especially biocompatible particles are not only important for biology application but also significant for obtaining accurate rotating results. Hence, in this paper, SU-8, one of the most biocompatible materials was selected as the manipulation object. AC electric field is employed to rotate SU-8 microrods, in order to obtain a controllable rotation angle for both the accurate experimental results and biosensor applications. Firstly, Clausius-Mossotti(CM) factors frequency spectra with different surface conductance and medium conductivities are presented, thereby the theoretical formula is carried out, including both the torque and rotation velocity expressions of SU-8 microrods. Moreover, simulations for the electric field distribution are developed, indicating the rotating direction. Secondly, the quadrupole electrodes are used to generate rotating electric field, and the electrorotation of SU-8 microrods in different medium is carried out, showing that the particles rotate in the opposite direction of the electric field, meanwhile, the peak frequency increases with the conductivity increases. Finally, the experimental results are discussed and compared with theoretical analysis, and the comparison result shows that they have a good agreement. This work proposes an effective and controllable method to rotate microrods, showing extend application potentials in microelectronics and biosensors.

  3. Transcranial direct current stimulation versus user training on improving online myoelectric control for amputees

    Science.gov (United States)

    Pan, Lizhi; Zhang, Dingguo; Jiang, Ning; Sheng, Xinjun; Zhu, Xiangyang

    2017-08-01

    Objective. Transcranial direct current stimulation (tDCS) and user training (UT) are two types of methods to improve myoelectric control performance for amputees. In this study, we compared the independent effect between tDCS and UT, and investigated the combined effect of tDCS and UT. Approach. An online paradigm of simultaneous and proportional control (SPC) based on electromyography (EMG) was adopted. The proposed experiments were conducted on six naïve unilateral trans-radial amputees. The subjects each received three types of 20 min interventions: active tDCS with motor training (tDCS  +  UT), active tDCS with quiet sitting (tDCS), and sham tDCS with motor training (UT). The interventions were applied at one week intervals in a randomized order. The subjects performed online control of a feedback arrow with two degrees of freedom (DoFs) to accomplish target reaching motor tasks in pre-sessions and post-sessions. We compared the performance, measured by completion rate, completion time, and efficiency coefficient, between pre-sessions and post-sessions. Main results. The results showed that the intervention tDCS  +  UT and tDCS significantly improved the online SPC performance (i.e. improved the completion rate; reduced the completion time; and improved the efficiency coefficient), while intervention UT did not significantly change the performance. The results also showed that the online SPC performance after intervention tDCS  +  UT and tDCS was not significantly different, but both were significantly better than that after intervention UT. Significance. tDCS could be an effective intervention to improve the online SPC performance in a short time.

  4. Novel Differential Current Control Strategy Based on a Modified Three-Level SVPWM for Two Parallel-Connected Inverters

    DEFF Research Database (Denmark)

    Zorig, Abdelmalik; Barkat, Said; Belkheiri, Mohammed

    2017-01-01

    current control method by introducing a control variable adjusting the dwell time of the selected switching vectors and thus maintaining the differential currents balanced without affecting the overall system performance. The control strategy, including distribution of switching sequence, selection......Recently, parallel inverters have been investigated to provide multilevel characteristics besides their advantage to increase the power system capacity, reliability, and efficiency. However, the issue of differential currents imbalance remains a challenge in parallel inverter operation....... The distribution of switching vectors of the resulting multilevel topology has a certain degree of self-differential current balancing properties. Nevertheless, the method alone is not sufficient to maintain balanced differential current in practical applications. This paper proposes a closed-loop differential...

  5. Safety and feasibility of transcranial direct current stimulation in pediatric hemiparesis: randomized controlled preliminary study.

    Science.gov (United States)

    Gillick, Bernadette T; Feyma, Tim; Menk, Jeremiah; Usset, Michelle; Vaith, Amy; Wood, Teddi Jean; Worthington, Rebecca; Krach, Linda E

    2015-03-01

    Transcranial direct current stimulation (tDCS) is a form of noninvasive brain stimulation that has shown improved adult stroke outcomes. Applying tDCS in children with congenital hemiparesis has not yet been explored. The primary objective of this study was to explore the safety and feasibility of single-session tDCS through an adverse events profile and symptom assessment within a double-blind, randomized placebo-controlled preliminary study in children with congenital hemiparesis. A secondary objective was to assess the stability of hand and cognitive function. A double-blind, randomized placebo-controlled pretest/posttest/follow-up study was conducted. The study was conducted in a university pediatric research laboratory. Thirteen children, ages 7 to 18 years, with congenital hemiparesis participated. Adverse events/safety assessment and hand function were measured. Participants were randomly assigned to either an intervention group or a control group, with safety and functional assessments at pretest, at posttest on the same day, and at a 1-week follow-up session. An intervention of 10 minutes of 0.7 mA tDCS was applied to bilateral primary motor cortices. The tDCS intervention was considered safe if there was no individual decline of 25% or group decline of 2 standard deviations for motor evoked potentials (MEPs) and behavioral data and no report of adverse events. No major adverse events were found, including no seizures. Two participants did not complete the study due to lack of MEP and discomfort. For the 11 participants who completed the study, group differences in MEPs and behavioral data did not exceed 2 standard deviations in those who received the tDCS (n=5) and those in the control group (n=6). The study was completed without the need for stopping per medical monitor and biostatisticial analysis. A limitation of the study was the small sample size, with data available for 11 participants. Based on the results of this study, tDCS appears to be safe

  6. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich...... were made at a reduced scale ( 2.2 kW). The constant power test showed that both method have good results which can respect existing grid codes. The constant power test showed that both method have good results which can respect existing grid codes....

  7. Use of alternating and pulsed direct current electrified fields for zebra mussel control

    Science.gov (United States)

    Luoma, James A.; Dean, Jan C.; Severson, Todd J.; Wise, Jeremy K.; Barbour, Matthew

    2017-01-01

    Alternatives to chemicals for controlling dreissenid mussels are desirable for environmental compatibility, but few alternatives exist. Previous studies have evaluated the use of electrified fields for stunning and/or killing planktonic life stages of dreissenid mussels, however, the available literature on the use of electrified fields to control adult dreissenid mussels is limited. We evaluated the effects of sinusoidal alternating current (AC) and 20% duty cycle square-wave pulsed direct current (PDC) exposure on the survival of adult zebra mussels at water temperatures of 10, 15, and 22 °C. Peak voltage gradients of ~ 17 and 30 Vp/cm in the AC and PDC exposures, respectively, were continuously applied for 24, 48, or 72 h. Peak power densities ranged from 77,999 to 107,199 µW/cm3 in the AC exposures and 245,320 to 313,945 µW/cm3 in the PDC exposures. The peak dose ranged from 6,739 to 27,298 Joules/cm3 and 21,306 to 80,941 Joules/cm3 in the AC and PDC exposures, respectively. The applied power ranged from 16.6 to 68.9 kWh in the AC exposures and from 22.2 to 86.4 kWh in the PDC exposures. Mortality ranged from 2.7 to 92.7% in the AC exposed groups and from 24.0 to 98.7% in PDC exposed groups. Mortality increased with corresponding increases in water temperature and exposure duration, and we observed more zebra mussel mortality in the PDC exposures. Exposures conducted with AC required less of a peak dose (Joules/cm3) but more applied power (kWh) to achieve the same level of adult zebra mussel mortality as corresponding PDC exposures. The results demonstrate that 20% duty cycle square-wave PDC requires less energy than sinusoidal AC to inducing the same level of adult zebra mussel mortality.

  8. Sensor-based control in eddy current separation of incinerator bottom ash.

    Science.gov (United States)

    Rahman, Md Abdur; Bakker, M C M

    2013-06-01

    A sensor unit was placed online in the particle stream produced by an eddy current separator (ECS) to investigate its functionality in non-ferrous metals recovery. The targeted feed was the 1-6mm size fraction bottom ash from a municipal waste incinerator. The sensor unit was attached to the ECS splitter, where it counted in real-time metal and mineral particles and accurately measured the grade of the stream in the metals product. Influence of segregation (e.g. due to particle size or density) on the metals concentrate were detected and studied using the sensor data collected at different splitter distances. Tests were performed in the laboratory and in a bottom ash processing plant with two different types of ECS and two sources of bottom ash with different moisture content. The measured metal grades matched the manual analyses with errors 0%, 1.5% and 3.1% for moist, dry and very wet feed, respectively. For very wet feed the ECS metals recovery dropped, which was observed from the strongly reduced particle counts and the large changes in cumulative particle properties. The measured sample proved representative for the whole metals concentrate if it is collected at a representative position within the metals particle trajectory fan produced by the ECS. ECS-performance proved sensitively dependent on splitter distance, since a 10mm shift may result in 10% change in metal recovery and 18% change in grade. The main functionalities of the sensor unit are determined as online quality control and facilitation of automatic control over the ECS splitter distance. These functionalities translate in significant improvements in ECS metals recovery which in turn is linked to economic benefits, increased recycling rate of scrap metals and a further reduction of the ecological drawbacks of incinerator bottom ash. Copyright © 2013 Elsevier Ltd. All rights reserved.

  9. Effects of Anodal Transcranial Direct Current Stimulation on Visually Guided Learning of Grip Force Control

    Directory of Open Access Journals (Sweden)

    Tamas Minarik

    2015-03-01

    Full Text Available Anodal transcranial Direct Current Stimulation (tDCS has been shown to be an effective non-invasive brain stimulation method for improving cognitive and motor functioning in patients with neurological deficits. tDCS over motor cortex (M1, for instance, facilitates motor learning in stroke patients. However, the literature on anodal tDCS effects on motor learning in healthy participants is inconclusive, and the effects of tDCS on visuo-motor integration are not well understood. In the present study we examined whether tDCS over the contralateral motor cortex enhances learning of grip-force output in a visually guided feedback task in young and neurologically healthy volunteers. Twenty minutes of 1 mA anodal tDCS were applied over the primary motor cortex (M1 contralateral to the dominant (right hand, during the first half of a 40 min power-grip task. This task required the control of a visual signal by modulating the strength of the power-grip for six seconds per trial. Each participant completed a two-session sham-controlled crossover protocol. The stimulation conditions were counterbalanced across participants and the sessions were one week apart. Performance measures comprised time-on-target and target-deviation, and were calculated for the periods of stimulation (or sham and during the afterphase respectively. Statistical analyses revealed significant performance improvements over the stimulation and the afterphase, but this learning effect was not modulated by tDCS condition. This suggests that the form of visuomotor learning taking place in the present task was not sensitive to neurostimulation. These null effects, together with similar reports for other types of motor tasks, lead to the proposition that tDCS facilitation of motor learning might be restricted to cases or situations where the motor system is challenged, such as motor deficits, advanced age, or very high task demand.

  10. Impact of a board-game approach on current smokers: a randomized controlled trial

    Directory of Open Access Journals (Sweden)

    Khazaal Yasser

    2013-01-01

    Full Text Available Abstract Background The main objective of our study was to assess the impact of a board game on smoking status and smoking-related variables in current smokers. To accomplish this objective, we conducted a randomized controlled trial comparing the game group with a psychoeducation group and a waiting-list control group. Methods The following measures were performed at participant inclusion, as well as after a 2-week and a 3-month follow-up period: “Attitudes Towards Smoking Scale” (ATS-18, “Smoking Self-Efficacy Questionnaire” (SEQ-12, “Attitudes Towards Nicotine Replacement Therapy” scale (ANRT-12, number of cigarettes smoked per day, stages of change, quit attempts, and smoking status. Furthermore, participants were assessed for concurrent psychiatric disorders and for the severity of nicotine dependence with the Fagerström Test for Nicotine Dependence (FTND. Results A time × group effect was observed for subscales of the ANRT-12, ATS-18 and SEQ-12, as well as for the number of cigarettes smoked per day. At three months follow-up, compared to the participants allocated to the waiting list group, those on Pick-Klop group were less likely to remain smoker. Outcomes at 3 months were not predicted by gender, age, FTND, stage of change, or psychiatric disorders at inclusion. Conclusions The board game seems to be a good option for smokers. The game led to improvements in variables known to predict quitting in smokers. Furthermore, it increased smoking-cessation rates at 3-months follow-up. The game is also an interesting alternative for smokers in the precontemplation stage.

  11. Outdoor biting by Anopheles mosquitoes on Bioko Island does not currently impact on malaria control.

    Science.gov (United States)

    Bradley, John; Lines, Jo; Fuseini, Godwin; Schwabe, Christopher; Monti, Feliciano; Slotman, Michel; Vargas, Daniel; Garcia, Guillermo; Hergott, Dianna; Kleinschmidt, Immo

    2015-04-21

    There have been many recent reports that the rate of outdoor biting by malaria vectors has increased. This study examined the impact this might have on malaria transmission by assessing the association between exposure to outdoor bites and malaria infection on Bioko Island, Equatorial Guinea. Responses to questions about time spent outside the previous night from a malaria indicator survey were combined with human landing catch measurements of hourly rates of outdoor and indoor biting for the whole island to estimate the number of outdoor and indoor bites received by each survey respondent. The association between RDT measured malaria infection status of individuals and outdoor bites received was investigated. The average number of bites received per person per night was estimated as 3.51 in total, of which 0.69 (19.7%) would occur outdoors. Malaria infection was not significantly higher in individuals who reported spending time outside between 7 pm and 6 am the previous night compared to those not spending time outside in both adults (18.9% vs 17.4%, p = 0.20) and children (29.2% vs 27.1%, p = 0.20). Malaria infection in neither adults (p = 0.56) nor in children (p = 0.12) was associated with exposure to outdoor bites, even after adjusting for confounders. Malaria vector mosquitoes in Bioko do bite humans outdoors, and this has the potential to reduce the effectiveness of vector control. However, outdoor biting is currently not a major factor influencing the malaria burden, mainly because more than 95% of the population are indoors during the middle of the night, which is the peak biting period for malaria vector mosquitoes. The majority of resources should remain with control measures that target indoor biting and resting such as LLINs and IRS.

  12. Malaria in Brazil, Colombia, Peru and Venezuela: current challenges in malaria control and elimination.

    Science.gov (United States)

    Recht, Judith; Siqueira, André M; Monteiro, Wuelton M; Herrera, Sonia M; Herrera, Sócrates; Lacerda, Marcus V G

    2017-07-04

    In spite of significant progress towards malaria control and elimination achieved in South America in the 2000s, this mosquito-transmitted tropical disease remains an important public health concern in the region. Most malaria cases in South America come from Amazon rain forest areas in northern countries, where more than half of malaria is caused by Plasmodium vivax, while Plasmodium falciparum malaria incidence has decreased in recent years. This review discusses current malaria data, policies and challenges in four South American Amazon countries: Brazil, Colombia, Peru and the Bolivarian Republic of Venezuela. Challenges to continuing efforts to further decrease malaria incidence in this region include: a significant increase in malaria cases in recent years in Venezuela, evidence of submicroscopic and asymptomatic infections, peri-urban malaria, gold mining-related malaria, malaria in pregnancy, glucose-6-phosphate dehydrogenase (G6PD) deficiency and primaquine use, and possible under-detection of Plasmodium malariae. Some of these challenges underscore the need to implement appropriate tools and procedures in specific regions, such as a field-compatible molecular malaria test, a P. malariae-specific test, malaria diagnosis and appropriate treatment as part of regular antenatal care visits, G6PD test before primaquine administration for P. vivax cases (with weekly primaquine regimen for G6PD deficient individuals), single low dose of primaquine for P. falciparum malaria in Colombia, and national and regional efforts to contain malaria spread in Venezuela urgently needed especially in mining areas. Joint efforts and commitment towards malaria control and elimination should be strategized based on examples of successful regional malaria fighting initiatives, such as PAMAFRO and RAVREDA/AMI.

  13. An advanced current control compensation scheme to improve the microgrid power quality without using dedicated compensation devices

    DEFF Research Database (Denmark)

    Naderipour, A.; Zin, A. A.Mohd; Habibuddin, M. H.

    2016-01-01

    of the harmonics in Microgrid (MG) and between MG and Power Common Coupling (PCC). The current harmonics in the grid and MG are compensated without using dedicated compensation devices, such as active power filters (APFs), by the proposed current controller which is contain an advanced synchronous reference frame...

  14. Associations of Trying to Lose Weight, Weight Control Behaviors, and Current Cigarette Use among US High School Students

    Science.gov (United States)

    Johnson, Jonetta L.; Eaton, Danice K.; Pederson, Linda L.; Lowry, Richard

    2009-01-01

    Background: Approximately one-quarter of high school students currently use cigarettes. Previous research has suggested some youth use smoking as a method for losing weight. The purpose of this study was to describe the association of current cigarette use with specific healthy and unhealthy weight control practices among 9th-12th grade students…

  15. The current level safety analysis of the nuclear power plant units based on the safety control charts using

    International Nuclear Information System (INIS)

    Aronov, I.Z.; Biryukova, N.F.; Grozovskij, G.I.

    1994-01-01

    The methodology of graphic analysis of current safery of a NPP unit using the safety control charts, on which the values of unit safety reiting and its statistical characteristics are plotted, is suggested. The conclusions about the current safety level are made basing on the reiting change dynamics analysis. Examples of the analysis are discussed

  16. Mite Pests in Plant Crops – Current Issues, Inovative Approaches and Possibilities for Controlling Them (1

    Directory of Open Access Journals (Sweden)

    Radmila Petanović

    2010-01-01

    Full Text Available In the middle of the last century, mites moved into the focus of attention as pests relevantto agriculture, forestry and landscape horticulture, presumably in direct reactionto the “green revolution” that involved plant cultivation in large-plot monocropping systems,improved methods of cultivation, selection of high-yielding cultivars and intensifieduse of pesticides and mineral fertilizers. Agroecosystems in which phytophagous miteshave become harmful organisms are primarily orchards, vineyards, greenhouses, urbangreeneries, plant nurseries and stored plant products, as well as annual field crops to asomewhat lesser degree. Phytophagous mite species belong to a variety of spider mites(Tetranychidae, false spider mites (Tenuipalpidae, gall and rust mites (Eriophyoidae, tarsonemidmites (Tarsonemidae and acarid mites (Acaridae. Most of these harmful speciesare widespread, some of them having more economic impact than others and being moredetrimental as depending on various specificities of each outdoor agroecosystem in anyparticular climatic region.The first segment of this overview focuses on the most significant mite pests ofagroecosystemsand urban horticultural areas in European countries, our own region andin Serbia today, primarily on species that have caused problems in recent years regardingplant production, and it also discusses various molecular methods available for investigatingdifferent aspects of the biology of phytophagous mites. Also, acaricides are discussedas a method of controlling mite pests in the light of the current situation and trends on pesticidemarkets in Serbia and the European Union member-countries

  17. Control of plasma properties in a short direct-current glow discharge with active boundaries

    Energy Technology Data Exchange (ETDEWEB)

    Adams, S. F. [Air Force Research Laboratory, WPAFB, Ohio 45433 (United States); Demidov, V. I., E-mail: vladimir.demidov@mail.wvu.edu [Air Force Research Laboratory, WPAFB, Ohio 45433 (United States); West Virginia University, Morgantown, West Virginia 26506 (United States); Bogdanov, E. A.; Kudryavtsev, A. A. [St. Petersburg State University, St. Petersburg 199034 (Russian Federation); Koepke, M. E. [West Virginia University, Morgantown, West Virginia 26506 (United States); Kurlyandskaya, I. P. [St. Petersburg University of State Fire Service of EMERCOM RF, Murmansk Branch, Murmansk 183040 (Russian Federation)

    2016-02-15

    To demonstrate controlling electron/metastable density ratio and electron temperature by applying negative voltages to the active (conducting) discharge wall in a low-pressure plasma with nonlocal electron energy distribution function, modeling has been performed in a short (lacking the positive-column region) direct-current glow discharge with a cold cathode. The applied negative voltage can modify the trapping of the low-energy part of the energetic electrons that are emitted from the cathode sheath and that arise from the atomic and molecular processes in the plasma within the device volume. These electrons are responsible for heating the slow, thermal electrons, while production of slow electrons (ions) and metastable atoms is mostly due to the energetic electrons with higher energies. Increasing electron temperature results in increasing decay rate of slow, thermal electrons (ions), while decay rate of metastable atoms and production rates of slow electrons (ions) and metastable atoms practically are unchanged. The result is in the variation of electron/metastable density ratio and electron temperature with the variation of the wall negative voltage.

  18. Quality control of brachytherapy equipment in the Netherlands and Belgium: current practice and minimum requirements

    International Nuclear Information System (INIS)

    Elfrink, Robert J.M.; Kolkman-Deurloo, Inger-Karine K.; Kleffens, Herman J. van; Rijnders, Alex; Schaeken, Bob; Aalbers, Tony H.L.; Dries, Wim J.F.; Venselaar, Jack L.M.

    2002-01-01

    Background and purpose: Brachytherapy is applied in 39 radiotherapy institutions in The Netherlands and Belgium. Each institution has its own quality control (QC) programme to ensure safe and accurate dose delivery to the patient. The main goal of this work is to gain insight into the current practice of QC of brachytherapy in The Netherlands and Belgium and to reduce possible variations in test frequencies and tolerances by formulating a set of minimum QC-requirements. Materials and methods: An extensive questionnaire about QC of brachytherapy was distributed to and completed by the 39 radiotherapy institutions. A separate smaller questionnaire was sent to nine institutions performing intracoronary brachytherapy. The questions were related to safety systems, physical irradiation parameters and total time spent on QC. The results of the questionnaires were compared with recommendations given in international brachytherapy QC reports. Results: The answers to the questionnaires showed large variations in test frequencies and test methods. Furthermore, large variations in time spent on QC exist, which is mainly due to differences in QC-philosophy and differences in the available resources. Conclusions: Based on the results of the questionnaires and the comparison with the international recommendations, a set of minimum requirements for QC of brachytherapy has been formulated. These guidelines will be implemented in the radiotherapy institutions in The Netherlands and Belgium

  19. Partial discharge measurements on 110kV current transformers. Setting the control value. Case study

    Science.gov (United States)

    Dan, C.; Morar, R.

    2017-05-01

    The case study presents a series of partial discharge measurements, reflecting the state of insulation of 110kV CURRENT TRANSFORMERS located in Sibiu county substations. Measurements were performed based on electrical method, using MPD600: an acquisition and analysis toolkit for detecting, recording, and analyzing partial discharges. MPD600 consists of one acquisition unit, an optical interface and a computer with dedicated software. The system allows measurements of partial discharge on site, even in presence of strong electromagnetic interferences because it provides synchronous acquisition from all measurement points. Therefore, measurements, with the ability to be calibrated, do render: - a value subject to interpretation according to IEC 61869-1:2007 + IEC 61869-2:2012 + IEC 61869-3:2011 + IEC 61869-5:2011 and IEC 60270: 2000; - the possibility to determine the quantitative limit of PD (a certain control value) to which the equipment can be operated safely and repaired with minimal costs (relative to the high costs implied by eliminating the consequences of a failure) identified empirically (process in which the instrument transformer subjected to the tests was completely destroyed).

  20. Current situation and control measures of groundwater pollution in gas station

    Science.gov (United States)

    Wu, Qiong; Zhang, Xiaofeng; Zhang, Qianjin

    2017-11-01

    In recent years, pollution accidents caused by gas station leakage has occurred worldwide which can be persistent in groundwater. Numerous studies have demonstrated that the contaminated groundwater is threatening the ecological environment and human health. In this article, current status and sources of groundwater pollution by gas station are analyzed, and experience of how to prevent groundwater pollution from gas stations are summarized. It is demonstrated that installation of secondary containment measures for the oil storage of the oil tank system, such as installation of double-layer oil tanks or construction of impermeable ponds, is a preferable method to prevent gas stations from groundwater pollution. Regarding to the problems of groundwater pollution caused by gas station, it is proposed that it is urgent to investigate the leakage status of gas station. Relevant precise implementation regulations shall be issued and carried out, and supervision management of gas stations would need to be strengthened. Then single-layer steel oil tanks shall be replaced by double-layer tanks, and the impermeable ponds should be constructed according to the risk ranking. From the control methodology, the groundwater environment monitoring systems, supervision level, laws and regulations as well as pollution remediation should also be carried out and strengthened.

  1. A Study of Heavy Metal Pollution in China: Current Status, Pollution-Control Policies and Countermeasures

    Directory of Open Access Journals (Sweden)

    Hui Hu

    2014-09-01

    Full Text Available In the past 30 years, China’s economy has experienced rapid development, which led to a vast increase in energy consumption and serious environmental pollution. Among the different types of pollution, heavy metal pollution has become one of the major environmental issues in China. A number of studies show that high level of heavy metal exposure is a frequent cause of permanent intellectual and developmental disabilities. In recent years, some traditional pollutants, such as sulfur dioxide and carbon dioxide, have been put under control in China. However, heavy metal pollution, which poses even greater risks to public health and sustainable development, has yet to gain policymakers’ attention. The purpose of this paper is to explore effective countermeasures for heavy metal pollution in China. The present study reviews the current status of China’s heavy metal pollution and analyzes related public policies and countermeasures against that pollution. It also presents a few recommendations and measures for prevention of heavy metal pollution.

  2. Control of spin injection by direct current in lateral spin valves

    OpenAIRE

    Casanova, Fèlix; Sharoni, Amos; Erekhinsky, Mikhail; Schuller, Ivan K.

    2008-01-01

    The spin injection and accumulation in metallic lateral spin valves with transparent interfaces is studied using d.c. injection current. Unlike a.c.-based techniques, this allows investigating the effects of the direction and magnitude of the injected current. We find that the spin accumulation is reversed by changing the direction of the injected current, whereas its magnitude does not change. The injection mechanism for both current directions is thus perfectly symmetric, leading to the sam...

  3. A current value Hamiltonian Approach for Discrete time Optimal Control Problems arising in Economic Growth

    OpenAIRE

    Naz, Rehana

    2018-01-01

    Pontrygin-type maximum principle is extended for the present value Hamiltonian systems and current value Hamiltonian systems of nonlinear difference equations for uniform time step $h$. A new method termed as a discrete time current value Hamiltonian method is established for the construction of first integrals for current value Hamiltonian systems of ordinary difference equations arising in Economic growth theory.

  4. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study. Volume 2: Appendices

    Science.gov (United States)

    Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.

    1981-01-01

    The current status of the Active Controls Technology (ACT) for the advanced subsonic transport project is investigated through analysis of the systems technical data. Control systems technologies under examination include computerized reliability analysis, pitch axis fly by wire actuator, flaperon actuation system design trade study, control law synthesis and analysis, flutter mode control and gust load alleviation analysis, and implementation of alternative ACT systems. Extensive analysis of the computer techniques involved in each system is included.

  5. CSF-2F control apparatus using eddy currents of two frequencies. Case of the Fessenheim 1 exchangers

    International Nuclear Information System (INIS)

    Pigeon, Michel; Saglio, Robert.

    1976-01-01

    The CFS-2F is a control apparatus using eddy currents which, through a proper choice of two frequencies can eliminate non-essential defects given by dimensional variations, plates, dudgeoning, etc... which could hide actual defects. An application of this apparatus for the control of exchanger tubes for Fessenheim 1 is then described [fr

  6. Chaos control in an electron beam with the supercritical current in the hydrodynamic model of the Pierce diode

    International Nuclear Information System (INIS)

    Koronovskij, A.A.; Rempen, I.S.; Khramov, A.E.

    2003-01-01

    The possibility of controlling the chaos in the electron beam with the supercritical current in the hydrodynamic model of the Pierce diode through the continuous feedback; the methodology of controlling the chaotic dynamics through stabilization of the unstable equilibrium state in the distributed active medium is proposed [ru

  7. Low-Cost Digital Implementation of Proportional-Resonant Current Controllers for PV Inverter Applications Using Delta Operator

    DEFF Research Database (Denmark)

    Sera, Dezso; Kerekes, Tamas; Lungeanu, Marian

    2005-01-01

    The performances of the P+Resonant controller in case of current control for a single phase grid connected inverter have been proved to be superior to the PI controller, since it is able to remove the phase error of the control at the fundamental frequency of the grid. It offers also the possibil......The performances of the P+Resonant controller in case of current control for a single phase grid connected inverter have been proved to be superior to the PI controller, since it is able to remove the phase error of the control at the fundamental frequency of the grid. It offers also...... of the P+Resonant controller with selective harmonic compensation on a low-cost fixed-point DSP. The resonant part of the P+R has been implemented as a second order filter based on Delta operator. The current controller, together with harmonic compensation for the 3rd, 5th, and 7th harmonics has been...

  8. Control Strategy for Three-Phase Grid-Connected PV Inverters Enabling Current Limitation Under Unbalanced Faults

    DEFF Research Database (Denmark)

    Afshari, Ehsan; Moradi, Gholam Reza; Rahimi, Ramin

    2017-01-01

    Power quality and voltage control are among the most important aspects of the grid-connected power converter operation under faults. Non-sinusoidal current is injected during unbalanced voltage sag and active or/and reactive power includes double frequency content. This paper introduces a novel...... control strategy to mitigate the double grid frequency oscillations in the active power and dc-link voltage of the two-stage three-phase grid-connected Photovoltaic (PV) inverters during unbalanced faults. With the proposed control method, PV inverter injects sinusoidal currents under unbalanced grid...... faults. In addition, an efficient and easy-to-implement current limitation method is introduced, which can effectively limit the injected currents to the rated value during faults. In this case, the fault-ride-through operation is ensured and it will not trigger the overcurrent protection. A non...

  9. Peak current mode control of three-phase boost rectifiers in discontinuous conduction mode for small wind power generators

    Energy Technology Data Exchange (ETDEWEB)

    Carranza, O. [Escuela Superior de Computo, Instituto Politecnico Nacional (Mexico); Garcera, G.; Figueres, E. [Grupo de Sistemas Electronicos Industriales del Departamento de Ingenieria Electronica, Universidad Politecnica de Valencia (Spain); Gonzalez, L.G. [Departamento de Ingenieria Electronica y Comunicaciones, Universidad de los Andes (Venezuela)

    2010-08-15

    This paper presents a peak current mode control scheme of a boost rectifier with low distortion of the input current for wind power systems based on permanent magnet synchronous generators with variable speed operation. The three-phase boost rectifier is operated in discontinuous conduction mode (DCM), and power factor correction techniques are applied. It is shown that the DCM operation significantly reduces the total harmonic distortion of the currents in the permanent magnet synchronous generator, increasing the power factor of the system, so that the vibrations and mechanical stress of the generator are minimized. The characteristics of the DCM boost rectifier are studied considering: (1) the series resistance of the inductors; (2) the modeling and adjustment of peak current mode control yielding a stable loop; (3) the design of an input filter that reduces the switching noise in the currents of the generator. (author)

  10. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study

    Science.gov (United States)

    1982-01-01

    The Current and Advanced Technology ACT control system definition tasks of the Integrated Application of Active Controls (IAAC) Technology project within the Energy Efficient Transport Program are summarized. The systems mechanize six active control functions: (1) pitch augmented stability; (2) angle of attack limiting; (3) lateral/directional augmented stability; (4) gust load alleviation; (5) maneuver load control; and (6) flutter mode control. The redundant digital control systems meet all function requirements with required reliability and declining weight and cost as advanced technology is introduced.

  11. A study of direct-current surface discharge plasma for a Mach 3 supersonic flow control

    Science.gov (United States)

    Shin, Jichul

    A direct-current, non-equilibrium surface glow discharge plasma in the presence of a Mach 2.85 flow is studied experimentally for flow control applications. The discharge is generated with pin-like electrodes flush mounted on a ceramic plate with sustaining currents from 25 mA to 300 mA. In the presence of a supersonic flow, two distinct discharge modes - diffuse and constricted - are observed depending on the flow and discharge operating conditions. In cathode upstream location, both diffuse and constricted discharges are observed while in cathode downstream location, the discharge mostly exhibits either constricted mode or bistable mixed mode. The effect of the discharge on the flow ("plasma actuation'') is characterized by the appearance of a weak shock wave in the vicinity of the discharge. The shock is observed at low powers (˜10 W) for the diffuse discharge mode but is absent for the higher power (˜100 W) constricted mode. High speed laser schlieren imaging suggests that the diffuse mode plasma actuation is rapid as it occurs on a time scale that is less than 100 microsec. Rotational (gas) and vibrational temperatures within the discharge are estimated by emission spectral line fits of N 2 and N+2 rovibronic bands near 365-395 nm. The electronic temperatures are estimated by using the Boltzmann plot method for Fe(I) atomic lines. Rotational temperatures are found to be high (˜1500 K) in the absence of a flow but drop sharply (˜500 K) in the presence of a supersonic flow for both the diffuse and constricted discharge modes. The vibrational and electronic temperatures are measured to be about 3000 K and 1.25 eV (14500 K), respectively, and these temperatures are the same with and without flow. The gas (rotational) temperature spatial profiles above the cathode surface are found to be similar for the diffuse and constricted modes indicating that dilatational effects due to gas heating are similar. However, complete absence of flow actuation for the

  12. Flexible Microgrid Power Quality Enhancement Using Adaptive Hybrid Voltage and Current Controller

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    -pass/bandpass filters in the DG unit digital controller. Moreover, phase-locked loops are not necessary as the microgrid frequency deviation can be automatically identified by the power control loop. Consequently, the proposed control method provides opportunities to reduce DG control complexity, without affecting...

  13. High performance predictive current control of a three phase VSI: An ...

    Indian Academy of Sciences (India)

    ... voltage as close as possible to the sinusoidal waveforms. Many control schemes are developed for the total harmonic reduction and switching loss minimization (Holtz 1994). Among the various control schemes available for power converters hysteresis based control and linear control combined with a modulation stage.

  14. Model-based drug administration : current status of target-controlled infusion and closed-loop control

    NARCIS (Netherlands)

    Kuizenga, Merel H.; Vereecke, Hugo E. M.; Struys, Michel M. R. F.

    Purpose of review Drug administration might be optimized by incorporating pharmacokinetic-dynamic (PK/PD) principles and control engineering theories. This review gives an update of the actual status of target-controlled infusion (TCI) and closed-loop computer-controlled drug administration and the

  15. Horizontal-Plane Trajectory-Tracking Control of an Underactuated Unmanned Marine Vehicle in the Presence of Ocean Currents

    Directory of Open Access Journals (Sweden)

    Zaopeng Dong

    2016-05-01

    Full Text Available Based on an integral backstepping approach, a trajectory-tracking control algorithm is proposed for an underactuated unmanned marine vehicle (UMV sailing in the presence of ocean-current disturbance. Taking into consideration the UMV model's fore/aft asymmetry, a nonlinear three-degree-of-freedom (3DOF underactuated dynamic model is established for the horizontal plane. First, trajectory-tracking differences between controllers designed based on symmetric and asymmetric models of the UMV are discussed. In order to explicitly study the effect of ocean-current interference on the trajectory-tracking controller, the ocean current is integrated into the kinematic and dynamic models of the UMV. Detailed descriptions of distinct trajectory-tracking control performances in the presence of different ocean-current velocities and direction angles are presented. The well-known persistent exciting (PE condition is completely released in the designed trajectory-tracking controller. A mild integral item of trajectory tracking error is merged into the control law, and global stability analysis of the UMV system is carried out using Lyapunov theory and Barbalat's Lemma. Simulation experiments in the semi-physical simulation platform are implemented to confirm the effectiveness and superiority of the excogitated control algorithm.

  16. Primary Droop Current-Sharing Control of the Parallel DC/DC Converters System considering Output Cable Resistance

    Directory of Open Access Journals (Sweden)

    J. B. Wang

    2011-01-01

    Full Text Available This paper presents a primary droop current-sharing controller that can integrate into voltage feedback controller and, thus, provides a low-cost and simple solution for parallel DC/DC converters system. From the equivalent small-signal model, a two-port network was adapted to describe the output and control variables for designing voltage and droop current-sharing loops. From the analysis results, the designed primary droop current-sharing controller will not affect the original voltage loop gain profile to let the DC/DC converter preserve desire control performance. After designing a stable DC/DC converter with primary droop current-sharing control, the stability of the interconnected parallel DC/DC converters system was studied. When the cable resistance is reduced, when the cable resistance is reduced, the interconnected system might be unstable. Finally, some simulation and experimental results demonstrated the effectiveness of the proposed controller in a prototype parallel DC/DC converters system.

  17. MHD-mode locking by controlled halo-current in T-10 tokamak

    International Nuclear Information System (INIS)

    Ivanov, N.V.

    2002-01-01

    The experiment on a non-disruptive halo-current influence on the m=2 mode rotation at the steady-state stage of tokamak discharge is presented. The halo current in the (Rail Limiter - Plasma - Vacuum Chamber - External Circuit - Rail Limiter) loop was used. The switching on of an EMF source in the external circuit resulted in locking of the m=2 magnetic islands by the halo current of 400 A amplitude. This effect can be attributed to a coupling between the halo-current magnetic field and the m=2/n=1 mode. A set of magnetic probes was used to measure the halo-current space structure in plasma. The dimensions of the halo-current path in plasma along the magnetic field were much shorter in poloidal and toroidal directions than the corresponding wavelengths for m=2/n=1 mode. The experiment was simulated in the assumption that the tearing mode is affected by halo-current helical component with the same space structure. The equation for disturbed poloidal flux in presence of external helical surface current was used for the analysis. In calculations for T-10 conditions the halo-current affected the mode rotation frequency, like it was observed in the experiment. (author)

  18. Soft controller switching technique to minimize the torque and current pulsations of a SCIM during its reswitching

    International Nuclear Information System (INIS)

    Larik, A.S.

    2010-01-01

    The direct-on-line starting of induction motor draws heavy current and to limit this Inrush current to a safe level normally a star-delta switch is used. However, the switching over from star to delta causes over current transients and this leads to torque pulsations. Therefore, in this paper the current and torque pulsations developed during the switching process are focused and a soft-switched controller is devised to minimize the re-closure transient currents and torque pulsations during star-delta switching of induction motor. The designed system can readily handles the sensing of favorable conditions of re closure of a switched-off running induction motor and it minimizes the inrush current and hence the pulsations of torque of all types of induction motors, whether, single-phase or three phase. An investigation is made into the transient currents and pulsation torques generated due to opening the circuit of a running induction motor and the switching pattern of star-delta switching. The re-switching control scheme for the induction motor is practically tested in the laboratory with and without soft controller. (author)

  19. Thyristor-based current-fed drive with direct power control for permanent magnet-assisted synchronous reluctance generator

    Science.gov (United States)

    Baek, J.; Kwak, S.-S.; Toliyat, H. A.

    2015-03-01

    This paper proposes a robust and simple direct power control (DPC) of a thyristor-based current-fed drive for generator applications. A current-fed drive and permanent magnet-assisted synchronous reluctance generator (PMa-SynRG) are investigated to deliver 3 kW power using a combustion engine. The current-fed drive utilises a thyristor-based three-phase rectifier to convert generator power to DC-link power and a single-phase current-fed inverter to supply a single-phase inductive load. In addition, a new control algorithm is developed based on DPC for the current-fed drive. The DC-link voltage-based DPC is proposed in order to directly control the output power. The goal of the DPC is to maintain the DC-link voltage at the required output power operating point. The DPC has advantages such as a simple algorithm for constant speed operation. Another feature of the developed current-fed drive is its inherent capability to provide generating action by making the PMa-SynRG operates as a generator, rectifying the phase voltages by means of the three-phase rectifier and feeding the power into the load. These features make the current-fed drive a good candidate for driving any type of synchronous generators including the proposed PMa-SynRG.

  20. Active Flow Control of Lifting Surface With Flap-Current Activities and Future Directions

    Science.gov (United States)

    Ahmadi, G.; Marzocca, P.; Jha, R.; Alstorm, B.; Obied, S.; Kabir, P.; Shahrabi, A.

    2010-01-01

    The main objective is to develop effective control strategies for separation control of an airfoil with a single hinge flap. The specific objectives are: Develop an active control architecture for flow control around an airfoil with flap. Design, fabricate, a wind tunnel test of a high lift wing (with flap) with integrated actuators and sensors. Design, development and fabrication of synthetic jet actuators. Develop appropriate control strategy for application to the airfoil. Wind tunnel testing of the high lift wing at various angles of attack and flap positions with closed loop control.

  1. Control of AC–DC grid side converter with single AC current sensor

    Indian Academy of Sciences (India)

    Himanshu Misra

    2017-11-24

    Nov 24, 2017 ... Introduction. Three-phase grid-connected pulse width modulation (PWM) converters have widespread applications such as motor drives, UPS, power quality conditioners and DFIG [1]. ..... in a-axis grid current (due to sensor and analog to digital .... current is proportional to the difference between refer-.

  2. Current controller considering harmonics compensation for grid connected converter in DPGS applications

    DEFF Research Database (Denmark)

    Barote, L.; Marinescu, C.; Teodorescu, Remus

    2012-01-01

    including a LC filter, a compensation technique for low-order harmonics and to examine the grid current harmonic content with and without harmonic compensation. A comparative study in terms of current harmonic distortion between two different values of PR proportional gain running in steady state condition...

  3. Current profile control via a plasma gun array in the rotating wall machine

    Science.gov (United States)

    Hannum, David; Bergerson, W.; Fiksel, G.; Forest, C. B.; Kendrick, R. D.; Lovell, T. W.; Sarff, J. S.

    2003-10-01

    The rotating wall machine is a linear screw-pinch built to study the role of different wall boundary conditions on the Resistive Wall Mode (RWM). Since the RWM is affected by details of the current profile, an array of nineteen plasma guns arranged in a hex or "honeycomb" pattern has been constructed to provide a wide variety of q-profiles in the experiment. Each gun supplies 1 kA of current, which terminates on one of three concentric anode rings at the opposite end of the plasma column. By individually changing the firing and biasing pattern of the guns and rings, different current profiles can be generated. The current profile is measured by monitoring the current to the anode rings. Initial results on the success of this array will be presented. This work is supported by DoE contract DE-FG02-00ER54603.

  4. An Optimal PR Control Strategy with Load Current Observer for a Three-Phase Voltage Source Inverter

    Directory of Open Access Journals (Sweden)

    Xiaobo Dou

    2015-07-01

    Full Text Available Inverter voltage control is an important task in the operation of a DC/AC microgrid system. To improve the inverter voltage control dynamics, traditional approaches attempt to measure and feedforward the load current, which, however, needs remote measurement with communications in a microgrid system with distributed loads. In this paper, a load current observer (LCO based control strategy, which does not need remote measurement, is proposed for sinusoidal signals tracking control of a three-phase inverter of the microgrid. With LCO, the load current is estimated precisely, acting as the feedforward of the dual-loop control, which can effectively enlarge the stability margin of the control system and improve the dynamic response to load disturbance. Furthermore, multiple PR regulators are applied in this strategy conducted in a stationary  frame to suppress the transient fluctuations and the total harmonic distortion (THD of the output voltage and achieve faster transient performance compared with traditional dual-loop control in a rotating dq0 frame under instantaneous change of various types of load (i.e., balanced load, unbalanced load, and nonlinear load. The parameters of multiple PR regulators are analyzed and selected through the root locus method and the stability of the whole control system is evaluated and analyzed. Finally, the validity of the proposed approach is verified through simulations and a three-phase prototype test system with a TMS320F28335 DSP.

  5. Control of AC–DC grid side converter with single AC current sensor

    Indian Academy of Sciences (India)

    Himanshu Misra

    2017-11-24

    Nov 24, 2017 ... as well as control of power factor at the grid side. Vector control and other control strategies of the ... section 6, which includes custom-build hardware for testing bidirectional power flow. Finally, conclusions ... and a DC-link capacitor between load and converter. The voltage at the mid-point of the leg is ...

  6. Fuzzy logic, PSO based fuzzy logic algorithm and current controls comparative for grid-connected hybrid system

    Science.gov (United States)

    Borni, A.; Abdelkrim, T.; Zaghba, L.; Bouchakour, A.; Lakhdari, A.; Zarour, L.

    2017-02-01

    In this paper the model of a grid connected hybrid system is presented. The hybrid system includes a variable speed wind turbine controlled by aFuzzy MPPT control, and a photovoltaic generator controlled with PSO Fuzzy MPPT control to compensate the power fluctuations caused by the wind in a short and long term, the inverter currents injected to the grid is controlled by a decoupled PI current control. In the first phase, we start by modeling of the conversion system components; the wind system is consisted of a turbine coupled to a gearless permanent magnet generator (PMG), the AC/DC and DC-DC (Boost) converter are responsible to feed the electric energy produced by the PMG to the DC-link. The solar system consists of a photovoltaic generator (GPV) connected to a DC/DC boost converter controlled by a PSO fuzzy MPPT control to extract at any moment the maximum available power at the GPV terminals, the system is based on maximum utilization of both of sources because of their complementary. At the end. The active power reached to the DC-link is injected to the grid through a DC/AC inverter, this function is achieved by controlling the DC bus voltage to keep it constant and close to its reference value, The simulation studies have been performed using Matlab/Simulink. It can be concluded that a good control system performance can be achieved.

  7. Coherent control of injection currents in high-quality films of Bi{sub 2}Se{sub 3}

    Energy Technology Data Exchange (ETDEWEB)

    Bas, D. A.; Vargas-Velez, K.; Babakiray, S.; Johnson, T. A.; Borisov, P.; Stanescu, T. D.; Lederman, D.; Bristow, A. D., E-mail: alan.bristow@mail.wvu.edu [Department of Physics and Astronomy, West Virginia University, Morgantown, West Virginia 26506-6315 (United States)

    2015-01-26

    Films of the topological insulator Bi{sub 2}Se{sub 3} are grown by molecular beam epitaxy with in-situ reflection high-energy electron diffraction. The films are shown to be high-quality by X-ray reflectivity and diffraction and atomic-force microscopy. Quantum interference control of photocurrents is observed by excitation with harmonically related pulses and detected by terahertz radiation. The injection current obeys the expected excitation irradiance dependence, showing linear dependence on the fundamental pulse irradiance and square-root irradiance dependence of the frequency-doubled optical pulses. The injection current also follows a sinusoidal relative-phase dependence between the two excitation pulses. These results confirm the third-order nonlinear optical origins of the coherently controlled injection current. Experiments are compared to a tight-binding band structure to illustrate the possible optical transitions that occur in creating the injection current.

  8. Effects of Transcranial Direct Current Stimulation, Transcranial Pulsed Current Stimulation, and Their Combination on Brain Oscillations in Patients with Chronic Visceral Pain: A Pilot Crossover Randomized Controlled Study

    Directory of Open Access Journals (Sweden)

    Aurore Thibaut

    2017-11-01

    Full Text Available ObjectiveChronic visceral pain (CVP syndromes are persistently painful disorders with a remarkable lack of effective treatment options. This study aimed at evaluating the effects of different neuromodulation techniques in patients with CVP on cortical activity, through electreocephalography (EEG and on pain perception, through clinical tests.DesignA pilot crossover randomized controlled study.SettingsOut-patient.SubjectsAdults with CVP (>3 months.MethodsParticipants received four interventions in a randomized order: (1 transcranial pulsed current stimulation (tPCS and active transcranial direct current stimulation (tDCS combined, (2 tPCS alone, (3 tDCS alone, and (4 sham condition. Resting state quantitative electroencephalography (qEEG and pain assessments were performed before and after each intervention. Results were compared with a cohort of 47 healthy controls.ResultsWe enrolled six patients with CVP for a total of 21 visits completed. Compared with healthy participants, patients with CVP showed altered cortical activity characterized by increased power in theta, alpha and beta bands, and a significant reduction in the alpha/beta ratio. Regarding tES, the combination of tDCS with tPCS had no effect on power in any of the bandwidths, nor brain regions. Comparing tPCS with tDCS alone, we found that tPCS induced higher increase in power within the theta and alpha bandwidths.ConclusionThis study confirms that patients with CVP present abnormal EEG-indexed cortical activity compared with healthy controls. Moreover, we showed that combining two types of neurostimulation techniques had no effect, whereas the two interventions, when applied individually, have different neural signatures.

  9. Gynecologic Cancer Prevention and Control in the National Comprehensive Cancer Control Program: Progress, Current Activities, and Future Directions

    OpenAIRE

    Stewart, Sherri L.; Lakhani, Naheed; Brown, Phaeydra M.; Larkin, O. Ann; Moore, Angela R.; Hayes, Nikki S.

    2013-01-01

    Gynecologic cancer confers a large burden among women in the United States. Several evidence-based interventions are available to reduce the incidence, morbidity, and mortality from these cancers. The National Comprehensive Cancer Control Program (NCCCP) is uniquely positioned to implement these interventions in the US population. This review discusses progress and future directions for the NCCCP in preventing and controlling gynecologic cancer.

  10. Gynecologic cancer prevention and control in the National Comprehensive Cancer Control Program: progress, current activities, and future directions.

    Science.gov (United States)

    Stewart, Sherri L; Lakhani, Naheed; Brown, Phaeydra M; Larkin, O Ann; Moore, Angela R; Hayes, Nikki S

    2013-08-01

    Gynecologic cancer confers a large burden among women in the United States. Several evidence-based interventions are available to reduce the incidence, morbidity, and mortality from these cancers. The National Comprehensive Cancer Control Program (NCCCP) is uniquely positioned to implement these interventions in the US population. This review discusses progress and future directions for the NCCCP in preventing and controlling gynecologic cancer.

  11. Overshoot Damping Control of DC Current at Deblock in AC-DC Interconnected System with Externally Commutated Converters

    Science.gov (United States)

    Kogiso, Keiji; Shimonosono, Takaaki

    Deblock of AC-DC interconnected system with externally commutated converters generally adopts soft start which makes trigger delay angle about 90 degrees and starts DC voltage from about 0kV. High DC voltage, however, is possibly caused by relation between the deblock signal and AC voltage phase at the commutation start of converter, resulting to overdue current. Consequently, overshoot of DC current is generated and transient AC voltage sag is caused especially under the condition of relatively weak AC system. We resolved the generation mechanism of DC current overshoot at deblock. In addition, we reflected the mechanism in the control system of Higashi-Shimizu FC, and drew up overshoot damping control by EMTP simulation. Furthermore, we checked the effect of overshoot damping control at the commissioning test period and verified that result of measurement corresponded with EMTP simulation.

  12. Effects of Combined Resistive Underwater Exercises and Interferential Current Therapy in Patients with Juvenile Idiopathic Arthritis: A Randomized Controlled Trial.

    Science.gov (United States)

    Elnaggar, Ragab K; Elshafey, Mohammed A

    2016-02-01

    The objective of this study was to verify the effects of combined resistive underwater exercises and interferential current on the peak torque of the quadriceps and hamstrings and pain levels in patients with juvenile idiopathic arthritis. This is a randomized controlled study; 30 children with polyarticular juvenile idiopathic arthritis were randomly distributed into two groups: the control group (n = 15) received the traditional physical therapy program and the study group (n = 15) received resistive underwater exercises and interferential current therapy. Peak torque of the quadriceps and hamstrings and pain levels were evaluated before treatment, 1 mo later, and after 3 mos using the HUMAC NORM, CSMI Testing and Rehabilitation Isokinetic System and visual analog scale, respectively. In the control group, all measures showed significant differences (P interferential current therapy is a potentially valuable treatment for patients with juvenile idiopathic arthritis.

  13. Comparison of PI and PR current controllers applied on two-level VSC-HVDC transmission system

    DEFF Research Database (Denmark)

    Manoloiu, A.; Pereria, H.A.; Teodorescu, Remus

    2015-01-01

    This paper analyzes differences between αβ and dq reference frames regarding the control of two-level VSC-HVDC current loop and dc-link voltage outer loop. In the first part, voltage feedforward effect is considered with PI and PR controllers. In the second part, the feedforward effect is removed...... and the PR gains are tuned to keep the dynamic performance. Also, the power feedforward is removed and the outer loop PI controller is tuned in order to maintain the system dynamic performance. The paper is completed with simulation results, which highlight the advantages of using PR controller....

  14. Dynamic Stability Enhancement and Power Flow Control of a Hybrid Wind and Marine-Current Farm Using SMES

    DEFF Research Database (Denmark)

    Wang, Li; Chen, Shiang-Shong; Lee, Wei-Jen

    2009-01-01

    This paper presents a control scheme based on a superconducting magnetic energy storage (SMES) unit to achieve both power flow control and damping enhancement of a novel hybrid wind and marine-current farm (MCF) connected to a large power grid. The performance of the studied wind farm (WF......) is simulated by an equivalent 80-MW induction generator (IG) while an equivalent 60-MW IG is employed to simulate the characteristics of theMCF. A damping controller for the SMES unit is designed by using modal control theory to contribute effective damping characteristics to the studied combined WF and MCF...

  15. Control algorithms based on the active and non-active currents for a UPQC without series transformers

    OpenAIRE

    Correa Monteiro, Luis Fernando; Aredes, Mauricio; Pinto, J. G.; Exposto, Bruno; Afonso, João L.

    2016-01-01

    This study presents control algorithms for a new unified power quality conditioner (UPQC) without the series transformers that are frequently used to make the insertion of the series converter of the UPQC between the power supply and the load. The behaviour of the proposed UPQC is evaluated in presence of voltage imbalances, as well as under non-sinusoidal voltage-and current conditions. The presented algorithms derive from the concepts involving the active and non-active currents, together w...

  16. Experimental Study on Vibration Control of a Submerged Pipeline Model by Eddy Current Tuned Mass Damper

    OpenAIRE

    Wenxi Wang; Dakota Dalton; Xugang Hua; Xiuyong Wang; Zhengqing Chen; Gangbing Song

    2017-01-01

    Undesirable vibrations occurring in undersea pipeline structures due to ocean currents may shorten the lifecycle of pipeline structures and even lead to their failure. Therefore, it is desirable to find a feasible and effective device to suppress the subsea vibration. Eddy current tuned mass damper (ECTMD), which employs the damping force generated by the relative movement of a non-magnetic conductive metal (such as copper or aluminum) through a magnetic field, is demonstrated to be an effici...

  17. Current control of the electron beam formed in the magnetron gun with a secondary-emission cathode

    International Nuclear Information System (INIS)

    Dovbnya, A.N.; Reshetnyak, N.G.; Zakutin, V.V.; Chertishchev, I.A.; Romas'ko, V.P.; Dovbnyan, N.A.

    2013-01-01

    Data are reported on electron beam generation and beam current control in two types of secondary-emission cathode magnetron guns. The influence of the magnetic field value and field distribution on the formation of the beam and its parameters has been investigated in the electron energy range between 20 and 150 keV. The influence of local magnetic field variations on the cathode and the electron beam characteristics has been studied. The possibility to control the electron beam current in various ways has been demonstrated

  18. Torque ripple reduction of brushless DC motor with harmonic current injection based on integral terminal sliding mode control

    DEFF Research Database (Denmark)

    Boroujeni, Mojtaba Shirvani; Markadeh, Gholamreza Arab; Soltani, Jafar

    2018-01-01

    Brushless Harmonic current injection to the stator windings is one of the most effective methods for torque ripple reduction of brushless DC motors. Because of multi harmonic contents of the stator currents, the conventional methods based on rotational reference frame cannot be used to calculate...... the voltage references for voltage source inverter. sliding mode control (SMC), which has high dynamic response to track a time varying command, can be used to force the arbitrary reference current to the stator windings without transfer the motor currents to the rotational reference frame. However, the main...... and performance of the proposed method, this method is compared with a SMC by some simulation and experimental tests. It is concluded that the dynamic response and robustness of the proposed ITSMC method is higher than SMC and ITSMC is an appropriate method to inject the arbitrary reference current to the motor...

  19. Dependence of CIT [Compact Ignition Tokamak] PF [poloidal field] coil currents on profile and shape parameters using the Control Matrix

    International Nuclear Information System (INIS)

    Strickler, D.J.; Peng, Y-K.M.; Jardin, S.C.; Pomphrey, N.

    1990-01-01

    The plasma shaping flexibility of the Compact Ignition Tokamak (CIT) poloidal field (PF) coil set is demonstrated through MHD equilibrium calculations of optimal PF coil current distributions and their variation with poloidal beta, internal inductance, plasma 95% elongation, and 95% triangularity. Calculations of the magnetic stored energy are used to compare solutions associated with various plasma parameters. The Control Matrix (CM) equilibrium code, together with the nonlinear equation and numerical optimization software packages HYBRD, and VMCON, respectively, are used to find equilibrium coil current distributions for fixed divertor geometry, volt-seconds, and plasma profiles in order to isolate the dependence on individual parameters. A reference equilibrium and coil current distribution are chosen, and correction currents dI are determined using the CM equilibrium method to obtain other specified plasma shapes. The reference equilibrium is the κ = 2 divertor at beginning of flattop (BOFT) with a minimum stored energy solution for the coil current distribution. The pressure profile function is fixed

  20. Energy-Regenerative Braking Control of Electric Vehicles Using Three-Phase Brushless Direct-Current Motors

    Directory of Open Access Journals (Sweden)

    Bo Long

    2013-12-01

    Full Text Available Regenerative braking provides an effective way of extending the driving range of battery powered electric vehicles (EVs. This paper analyzes the equivalent power circuit and operation principles of an EV using regenerative braking control technology. During the braking period, the switching sequence of the power converter is controlled to inverse the output torque of the three-phase brushless direct-current (DC motor, so that the braking energy can be returned to the battery. Compared with the presented methods, this technology can achieve several goals: energy recovery, electric braking, ultra-quiet braking and extending the driving range. Merits and drawbacks of different braking control strategy are further elaborated. State-space model of the EVs under energy-regenerative braking operation is established, considering that parameter variations are unavoidable due to temperature change, measured error, un-modeled dynamics, external disturbance and time-varying system parameters, a sliding mode robust controller (SMRC is designed and implemented. Phase current and DC-link voltage are selected as the state variables, respectively. The corresponding control law is also provided. The proposed control scheme is compared with a conventional proportional-integral (PI controller. A laboratory EV for experiment is setup to verify the proposed scheme. Experimental results show that the drive range of EVs can be improved about 17% using the proposed controller with energy-regeneration control.

  1. Start-up current adaptive control for sensorless high-speed brushless DC motors based on inverse system method and internal mode controller

    Directory of Open Access Journals (Sweden)

    Yanzhao He

    2017-02-01

    Full Text Available The start-up current control of the high-speed brushless DC (HS-BLDC motor is a challenging research topic. To effectively control the start-up current of the sensorless HS-BLDC motor, an adaptive control method is proposed based on the adaptive neural network (ANN inverse system and the two degrees of freedom (2-DOF internal model controller (IMC. The HS-BLDC motor is identified by the online least squares support vector machine (OLS-SVM algorithm to regulate the ANN inverse controller parameters in real time. A pseudo linear system is developed by introducing the constructed real-time inverse system into the original HS-BLDC motor system. Based on the characteristics of the pseudo linear system, an extra closed-loop feedback control strategy based on the 2-DOF IMC is proposed to improve the transient response performance and enhance the stability of the control system. The simulation and experimental results show that the proposed control method is effective and perfect start-up current tracking performance is achieved.

  2. An Enhanced Instantaneous Circulating Current Control for Reactive power and Harmonic Load Sharing in Islanded Microgrids

    DEFF Research Database (Denmark)

    Lorzadeh, Iman; Askarian Abyaneh, Hossein; Savaghebi, Mehdi

    2017-01-01

    To address inaccurate load demand sharing problems among parallel inverter-interfaced voltage-controlled distributed generation (DG) units in islanded microgrids with different DG power ratings and mismatched feeder impedances, an enhanced voltage control scheme based on actively compensation of ...

  3. A Decentralized Current-Sharing Controller Endows Fast Transient Response to Parallel DC-DC Converters

    DEFF Research Database (Denmark)

    Wang, Haojie; Han, Minxiao; Han, Renke

    2018-01-01

    that of the conventional V-I droop control. Furthermore, by analyzing the effects from I-V droop control parameters, the errors can be reduced faster by enlarging the proportional terms, but with no fluctuations, and then completely eliminated by restoring back to small proportional values. Meanwhile, there exists a trade...

  4. Independent Control of Positive- and Negative-Sequence Current Components in a Doubly Fed Machine

    Czech Academy of Sciences Publication Activity Database

    Bendl, Jiří; Chomát, Miroslav; Schreier, Luděk

    2005-01-01

    Roč. 15, č. 3 (2005), s. 191-202 ISSN 1430-144X R&D Projects: GA ČR(CZ) GA102/03/0046 Institutional research plan: CEZ:AV0Z20570509 Keywords : vector control * adjustable speed generation systems * converter control Subject RIV: JA - Electronics ; Optoelectronics, Electrical Engineering Impact factor: 0.056, year: 2005

  5. Load Torque Compensator for Model Predictive Direct Current Control in High Power PMSM Drive Systems

    DEFF Research Database (Denmark)

    Preindl, Matthias; Schaltz, Erik

    2011-01-01

    The widely used cascade speed and torque controllers have a limited control performance in most high power applications due to the low switching frequency of power electronic converters and the convenience to avoid speed overshoots and oscillations for lifetime considerations. Model Predictive...

  6. Chattering Suppression for DSP Based Sliding Mode Current Control of PM DC Drives

    DEFF Research Database (Denmark)

    Dal, Mehmet; Teodorescu, Remus

    2009-01-01

    This paper investigates several chattering suppression methods for DSP based implementation of sliding mode control (SMC). It concentrates on the ‘equivalent-control-dependent' and ‘state-dependent' gain adjustment methods proposed in recent theoretical studies, and tests the effectiveness...... (LPF). Experimental results demonstrating the effectiveness of each method as well as a combined chattering elimination method are presented and discussed....

  7. Low-Cost Digital Implementation of Proportional-Resonant Current Controllers for PV Inverter Applications Using Delta Operator

    DEFF Research Database (Denmark)

    Sera, Dezso; Kerekes, Tamas; Lungeanu, Marian

    2005-01-01

    The performances of the P+Resonant controller in case of current control for a single phase grid connected inverter have been proved to be superior to the PI controller, since it is able to remove the phase error of the control at the fundamental frequency of the grid. It offers also the possibil...... successfully tested in practice with a 1.5KW PV inverter, achieving a 1.2% Total Harmonic Distortion (THD) of the grid current....... the possibility of selective harmonic compensation. However, in case of digital implementation on a low-cost fixedpoint DSP, the limited computational power and the limited numerical representation precision can restrict the utilization of it. The present paper proposes a different way of digital implementation...... of the P+Resonant controller with selective harmonic compensation on a low-cost fixed-point DSP. The resonant part of the P+R has been implemented as a second order filter based on Delta operator. The current controller, together with harmonic compensation for the 3rd, 5th, and 7th harmonics has been...

  8. Improvement of automatic control system for high-speed current collectors

    Science.gov (United States)

    Sidorov, O. A.; Goryunov, V. N.; Golubkov, A. S.

    2018-01-01

    The article considers the ways of regulation of pantographs to provide quality and reliability of current collection at high speeds. To assess impact of regulation was proposed integral criterion of the quality of current collection, taking into account efficiency and reliability of operation of the pantograph. The study was carried out using mathematical model of interaction of pantograph and catenary system, allowing to assess contact force and intensity of arcing at the contact zone at different movement speeds. The simulation results allowed us to estimate the efficiency of different methods of regulation of pantographs and determine the best option.

  9. The Control System of CERN Accelerators Vacuum (Current Status and Recent Improvements)

    CERN Document Server

    Gomes, P; Blanchard, S; Boccioli, M; Girardot, G; Vestergard, H; Kopylov, L; Mikheev, M

    2011-01-01

    The vacuum control system of most of the CERN accelerators is based on Siemens PLCs and on PVSS SCADA. After the transition from the LHC commissioning phase to its regular operation, there has been a number of additions and improvements to the vacuum control system. They were driven by new technical requirements and by feedback from the accelerator operators and vacuum specialists. New control functions have been implemented in the PLCs; new tools have been developed for the SCADA, while its ergonomics and navigation have been enhanced.

  10. The control system of CERN accelerators vacuum (current status and recent improvements)

    International Nuclear Information System (INIS)

    Gomes, P.; Antoniotti, F.; Blanchard, S.; Boccioli, M.; Girardot, G.; Vestergard, H.; Kopylov, L.; Mikheev, M.

    2012-01-01

    The vacuum control system of most of the CERN accelerators is based on Siemens PLCs and on PVSS SCADA. After the transition from the LHC commissioning phase to its regular operation, there has been a number of additions and improvements to the vacuum control system. They were driven by new technical requirements and by feedback from the accelerator operators and vacuum specialists. New control functions have been implemented in the PLCs; new tools have been developed for the SCADA, while its ergonomic and navigation have been enhanced. (authors)

  11. A Secondary-Control Based Fault Current Limiter for Four-Wire Three Phase Inverter-Interfaced DGs

    DEFF Research Database (Denmark)

    Beheshtaein, Siavash; Savaghebi, Mehdi; Guerrero, Josep M.

    2017-01-01

    this gap by proposing an embedded FCL operating based on modifying the secondary control of DGs. As this method is designed for four-wire system, besides cost-effectiveness, it has independency and flexibility to only limit the fault current of DG. In order to validate the proposed method, different types...

  12. Control of current inverters in decentral power systems as active filters; Regelung von Netzstromrichtern in dezentralen Energiesystemen als aktive Filter

    Energy Technology Data Exchange (ETDEWEB)

    Merfert, Igor; Lindemann, Andreas [Magdeburg Univ. (Germany). Lehrstuhl fuer Leistungselektronik

    2007-07-01

    Besides their main task, decentralized power generators can combine electric power generation with system services if the inverter has current capability to spare. This paper deals with the system services, power quality improvement and a reactive power compensation, in a fuel cell based decentralized electrical power generator. A control strategy and a practical realization are introduced. (orig.)

  13. An Improved Current Controller to ensure the robust performance of grid-connected converters under weak grid conditions

    DEFF Research Database (Denmark)

    Khazraj, Hesam; Silva, Filipe Miguel Faria da; Bak, Claus Leth

    2016-01-01

    Voltage Source Converters (VSCs) operating in very weak grids with low Short Circuit Ratio (SCR) are known to meet stability challenges. This article investigates instability of a grid connected current-controlled converter under weak grid conditions, which is often attributed to the dynamic...

  14. THE CONTROLLED CHOKE TRANSFORMER IN THE STRUCTURE OF THE ELECTROMECHANICAL SYSTEM FOR GENERATING ALTERNATING CURRENT OF FIXED FREQUENCY

    Directory of Open Access Journals (Sweden)

    S. V. Mishin

    2015-01-01

    Full Text Available This article briefly describes the design of controlled choke transformer regulator. The electrical circuit and the results of laboratory tests in the form of characteristics of idling, short circuit and performance are presented. The expediency of application of such devices in the electromechanical system of generating alternating current of constant frequency is grounded.

  15. A Novel Modulation Function-Based Control of Modular Multilevel Converters for High Voltage Direct Current Transmission Systems

    Directory of Open Access Journals (Sweden)

    Majid Mehrasa

    2016-10-01

    Full Text Available In this paper, a novel modulation function-based method including analyses of the modulation index and phase is proposed for operation of modular multilevel converters (MMCs in high voltage direct current (HVDC transmission systems. The proposed modulation function-based control technique is developed based on thorough and precise analyses of all MMC voltages and currents in the a-b-c reference frame in which the alternating current (AC-side voltage is the first target to be obtained. Using the AC-side voltage, the combination of the MMC upper and lower arm voltages is achieved as the main structure of the proposed modulation function. The main contribution of this paper is to obtain two very simple new modulation functions to control MMC performance in different operating conditions. The features of the modulation function-based control technique are as follows: (1 this control technique is very simple and can be easily achieved in a-b-c reference frame without the need of using Park transformation; and (2 in addition, the inherent properties of the MMC model are considered in the proposed control technique. Considering these properties leads to constructing a control technique that is robust against MMC parameters changes and also is a very good tracking method for the components of MMC input currents. These features lead to improving the operation of MMC significantly, which can act as a rectifier in the HVDC structure. The simulation studies are conducted through MATLAB/SIMULINK software, and the results obtained verify the effectiveness of the proposed modulation function-based control technique.

  16. The control of stainless steel tubes and wires of small diameter by the Eddy current method

    International Nuclear Information System (INIS)

    Stossel, A.; Gallet, G.

    1978-01-01

    Stainless steel tubes and wires with an outer diameter greater than 1 mm were studied by Eddy currents. The sensor characteristics and the detection of defects in function of frequency are presented together with the results obtained in the detection of dimensional and metallurgical defects [fr

  17. Eddy Current, Magnetic Particle and Hardness Testing, Aviation Quality Control (Advanced): 9227.04.

    Science.gov (United States)

    Dade County Public Schools, Miami, FL.

    This unit of instruction includes the principles of eddy current, magnetic particle and hardness testing; standards used for analyzing test results; techniques of operating equipment; interpretation of indications; advantages and limitations of these methods of testing; care and calibration of equipment; and safety and work precautions. Motion…

  18. Transcranial direct current stimulation in refractory continuous spikes and waves during slow sleep: a controlled study

    DEFF Research Database (Denmark)

    Varga, Edina T; Terney, Daniella; Atkins, Mary D

    2011-01-01

    Cathodal transcranial direct current stimulation (tDCS) decreases cortical excitability. The purpose of the study was to investigate whether cathodal tDCS could interrupt the continuous epileptiform activity. Five patients with focal, refractory continuous spikes and waves during slow sleep were...

  19. Spatial temperature control with a 27 MHz current source interstitial hyperthermia system

    NARCIS (Netherlands)

    Kaatee, R. S.; Crezee, H.; Kanis, B. P.; Lagendijk, J. J.; Levendag, P. C.; Visser, A. G.

    1997-01-01

    This article gives an overview of the properties of a 27 MHz current source interstitial hyperthermia system, affecting temperature uniformity. Applicators can be inserted in standard flexible afterloading catheters. Maximum temperatures are measured with seven-point constantan-manganin thermocouple

  20. Model-guided control of hippocampal discharges by local direct current stimulation.

    Science.gov (United States)

    Mina, Faten; Modolo, Julien; Recher, Fanny; Dieuset, Gabriel; Biraben, Arnaud; Benquet, Pascal; Wendling, Fabrice

    2017-05-10

    Neurostimulation is an emerging treatment for drug-resistant epilepsies when surgery is contraindicated. Recent clinical results demonstrate significant seizure frequency reduction in epileptic patients, however the mechanisms underlying this therapeutic effect are largely unknown. This study aimed at gaining insights into local direct current stimulation (LDCS) effects on hyperexcitable tissue, by i) analyzing the impact of electrical currents locally applied on epileptogenic brain regions, and ii) characterizing currents achieving an "anti-epileptic" effect (excitability reduction). First, a neural mass model of hippocampal circuits was extended to accurately reproduce the features of hippocampal paroxysmal discharges (HPD) observed in a mouse model of epilepsy. Second, model predictions regarding current intensity and stimulation polarity were confronted to in vivo mice recordings during LDCS (n = 8). The neural mass model was able to generate realistic hippocampal discharges. Simulation of LDCS in the model pointed at a significant decrease of simulated HPD (in duration and occurrence rate, not in amplitude) for cathodal stimulation, which was successfully verified experimentally in epileptic mice. Despite the simplicity of our stimulation protocol, these results contribute to a better understanding of clinical benefits observed in epileptic patients with implanted neurostimulators. Our results also provide further support for model-guided design of neuromodulation therapy.

  1. Performance of unified power quality conditioner (UPQC) based on fuzzy controller for attenuating of voltage and current harmonics

    Science.gov (United States)

    Milood Almelian, Mohamad; Mohd, Izzeldin I.; Asghaiyer Omran, Mohamed; Ullah Sheikh, Usman

    2018-04-01

    Power quality-related issues such as current and voltage distortions can adversely affect home and industrial appliances. Although several conventional techniques such as the use of passive and active filters have been developed to increase power quality standards, these methods have challenges and are inadequate due to the increasing number of applications. The Unified Power Quality Conditioner (UPQC) is a modern strategy towards correcting the imperfections of voltage and load current supply. A UPQC is a combination of both series and shunt active power filters in a back-to-back manner with a common DC link capacitor. The control of the voltage of the DC link capacitor is important in achieving a desired UPQC performance. In this paper, the UPQC with a Fuzzy logic controller (FLC) was used to precisely eliminate the imperfections of voltage and current harmonics. The results of the simulation studies using MATLAB/Simulink and Simpower system programming for R-L load associated through an uncontrolled bridge rectifier was used to assess the execution process. The UPQC with FLC was simulated for a system with distorted load current and a system with distorted source voltage and load current. The outcome of the comparison of %THD in the load current and source voltage before and after using UPQC for the two cases was presented.

  2. Assesment and Analyze Hybride Control System in Distribution Static Synchronous Compensator Based Current Source Converter

    Directory of Open Access Journals (Sweden)

    Seyed Mohammad Ali Zanjani

    2011-10-01

    Full Text Available With the rapid technology advancement in control processes, electric utilities are experiencing more demanding requirements on the power quality from the large industrial power consumers. For achieved this purpose use of FACTS devices. One of kind compensator is D-Statcom, using in distribution system for conquest of power quality problem. This paper presents system modeling and control design techniques of distribution static synchronous compensator. For reach an optimal design, using a hybride state-feedback and d-q control systems. Using direct sampling on network parameter, than conventional control system, as well as fast dynamic responses are achieved. The derived simulations are tried to verify the result of this paper.

  3. Fuzzy control techniques applied to a three phase synchronous rectifier current loop

    Directory of Open Access Journals (Sweden)

    Alberto Berzoy-Lleren

    2015-01-01

    Full Text Available Este trabajo presenta tres técnicas de control difuso de estructura variable (FVSC aplicadas al lazo de control de corriente en un rectificador síncrono trifásico. Estas técnicas se basan en un controlador PI difuso Takagi-Sugeno (T-S. El primer controlador es un FVSC de primer orden que se usa como referencia. A continuación se presentan y prueban dos estrategias FVSC, FVSC de segundo y tercer orden. Estos esquemas de control se simulan primero y luego se prueban en un rectificador síncrono de propósito general de laboratorio. Los resultados experimentales muestran que el rendimiento del control es bueno en los tres esquemas, logrando compensación de las corrientes armónicas y corrección del factor de potencia.

  4. Current and Future Challenges for Asian Nonproliferation Export Controls: A Regional Response

    National Research Council Canada - National Science Library

    Jones, Scott

    2004-01-01

    .... The distinction between military and commercial products has become less clear. Therefore, it is likely that export control policies and institutions need to be continually adjusted if they are to serve international security objectives...

  5. Current and Future Challenges for Asian Nonproliferation Export Controls: A Regional Response

    National Research Council Canada - National Science Library

    Jones, Scott

    2004-01-01

    .... However, the effectiveness of export control as a tool for limiting the spread of sensitive technologies and weaponry has been compromised by globalization and a complex array of international developments...

  6. [Transcranial alternating current stimulation. Entrainment and function control of neuronal networks].

    Science.gov (United States)

    Vosskuhl, J; Strüber, D; Herrmann, C S

    2015-12-01

    Transcranial alternating current stimulation (tACS) is a new technique for the modulation of oscillatory brain activity as measured in the electroencephalogram (EEG). In contrast to well-established stimulation techniques, such as transcranial direct current stimulation and transcranial magnetic stimulation, tACS applies a sinusoidal alternating current at a specific frequency. This enables the modulation of the amplitude and frequency of endogenous brain oscillations as well as related cognitive processes. Therefore, the use of tACS has the possibility to evaluate well-known correlations between brain oscillations and cognitive processes in terms of causality. Such causal relationships have been documented in numerous neurocognitive studies on sensory, motor and perceptual processes; however, the clinical application of tACS is still in its infancy. In principle, any pathology that can reliably be connected with brain oscillations of a defined frequency is treatable. A current main focus of clinical research is on symptoms of Parkinson's disease and to a lesser degree, tinnitus. For an effective application of tACS it is important to choose the electrode positions as well as the frequency, intensity and duration of the stimulation in a theory-based and symptom-related manner. A successful therapeutic intervention requires the persistence of the tACS effect after stimulation has ceased. A mechanism that offers not only an explanation to the origin of persistent tACS effects but is also of high therapeutic benefit is neural plasticity. Therefore, one current focus of research aims at a better understanding of tACS after effects.

  7. Characteristic Analysis and Fault-Tolerant Control of Circulating Current for Modular Multilevel Converters under Sub-Module Faults

    Directory of Open Access Journals (Sweden)

    Wen Wu

    2017-11-01

    Full Text Available A modular multilevel converter (MMC is considered to be a promising topology for medium- or high-power applications. However, a significantly increased amount of sub-modules (SMs in each arm also increase the risk of failures. Focusing on the fault-tolerant operation issue for the MMC under SM faults, the operation characteristics of MMC with different numbers of faulty SMs in the arms are analyzed and summarized in this paper. Based on the characteristics, a novel circulating current-suppressing (CCS fault-tolerant control strategy comprised of a basic control unit (BCU and virtual resistance compensation control unit (VRCCU in two parts is proposed, which has three main features: (i it can suppress the multi-different frequency components of the circulating current under different SM fault types simultaneously; (ii it can help fast limiting of the transient fault current caused at the faulty SM bypassed moment; and (iii it does not need extra communication systems to acquire the information of the number of faulty SMs. Moreover, by analyzing the stability performance of the proposed controller using the Root-Locus criterion, the election principle of the value of virtual resistance is revealed. Finally, the efficiency of the control strategy is confirmed with the simulation and experiment studies under different fault conditions.

  8. Principle and Control Design of Active Ground-Fault Arc Suppression Device for Full Compensation of Ground Current

    DEFF Research Database (Denmark)

    Wang, Wen; Zeng, Xiangjun; Yan, Lingjie

    2017-01-01

    . The commonly-used large-capacity reactive component may bring about overvoltage because of possible resonance with the distributed phase-to-ground capacitance. To solve these problems, an active ground-fault arc suppression device is presented. It employs a topology based on single-phase inverter to inject...... suppression without capacitive current detection. Its time-based feature also brings the benefit of fast response on ground-fault arc suppression. The principle of full current compensation is analyzed, together with the controller design method of the proposed device. Experiment on a prototype was carried......Traditional ground-fault arc suppression devices mainly deal with capacitive component of ground current and have weak effect on the active and harmonic ones, which limits the arc suppression performance. The capacitive current detection needed in them suffers from low accuracy and robustness...

  9. An Example of Easy Synthesis of Active Filter and Oscillator using Signal Flowgraph Modification and Controllable Current Conveyors

    Science.gov (United States)

    Šotner, Roman; Hruboš, Zdeněk; Ševčík, Břetislav; Slezák, Josef; Petržela, Jiří; Dostál, Tomáš

    2011-09-01

    The paper deals with synthesis of active frequency filters and oscillators for applications in the video band. The synthesis is based on the modified signal flow graph design approach in the current mode. The commercially available high frequency current conveyors and second order structures are used. Basic structure is employing loss-less and lossy current mode integrators in two distributed feedback loops. Some of the used active elements allow to control current gain which is very useful in applications. High frequency multi-functional filter and electronically adjustable quadrature oscillator configurations are discussed. Most of the used passive elements (mainly capacitors) are grounded which is suitable for IC implementation. Simulation and experimental results demonstrate function and features very well.

  10. Biological control of fruit flies (Diptera: Tephritidae) through parasitoid augmentative releases: Current status

    International Nuclear Information System (INIS)

    Montoya, Pablo; Liedo, Pablo

    2000-01-01

    Fruit flies are among the main pests affecting the world fruit industry (Aluja 1993). Bait sprays have traditionally been used successfully to control them; however, the side effects on the environment and health hazards commonly associated with pesticides, have resulted in strong public opposition to the use of bait sprays. This is particularly so when sprays are applied in urban areas or in coffee plantations where, although Medflies are present, they do not pose a danger to crops. Alternative methods that are effective and environmental friendly to suppress fruit fly populations are highly desirable. Biological control, the use of natural enemies to suppress pest populations, represents such an alternative. Some of the most successful cases of biological control are the control of Iceria purchasi Maskell (Homoptera: Margarodidae) by Rodolia cardinalis Mulsant (Coleoptera: Coccinellidae) in California (De Bach 1968, van den Bosch et al. 1982), and the control of Aleurocanthus woglumi Ashby (Homoptera: Aleyrodidae) mainly by Encarsia (=Prospaltella) opulenta Silv. (Hymenoptera: Aphelinidae) in Mexico (Jimenez 1961, 1971), both using the classical approach. However, this approach has been limited to certain conditions of environmental stability and biodiversity which are only found in a few ecosystems. Other factors, such as types of pests, the economic threshold and product quality requirements represent additional limitations. The best option in many cases could be augmentative biological control, which could overcome some of the deficiencies of the classical approach (Sivinski 1996). According to Knipling (1992) and Barclay (1987), augmentative biological control can be considered as a formal alternative for suppressing pest populations and even for use in eradication programmes, after integration with the sterile insect technique (SIT). In this approach, mass production of natural enemies is required and this production has to be cost effective

  11. A new stator-flux orientation strategy for flux-switching permanent magnet motor based on current-hysteresis control

    Science.gov (United States)

    Hua, Wei; Cheng, Ming; Lu, Wei; Jia, Hongyun

    2009-04-01

    A stator-flux orientation strategy based on current hysteresis for the flux-switching permanent magnet (FSPM) motor is proposed, in which the stator-PM FSPM motor is considered as a conventional rotor-PM surface-mounted motor and an equivalent rotor-orientated dq-axes synchronous reference frame is built although there are actually no rotary magnetic motive force produced by the stator magnets in the FSPM motor. Based on the proposed model, a vector-control strategy with current hysteresis for the FSPM motor drive is investigated and implemented on a dSPACE-based platform, and both the simulated and experimental results validate the effectiveness. It should be emphasized that the proposed stator-flux orientation strategy can be applied to other stator-PM machines (including doubly salient and flux-reversal PM machines) and other control methods (including space-vector pulsed-width-modification and direct torque control).

  12. Controlling threshold voltage and leakage currents in vertical organic field-effect transistors by inversion mode operation

    Science.gov (United States)

    Günther, Alrun A.; Hossbach, Christoph; Sawatzki, Michael; Kasemann, Daniel; Bartha, Johann W.; Leo, Karl

    2015-12-01

    The interest in vertical organic transistors as a means to overcome the limitations of conventional organic field-effect transistors (OFETs) has been growing steadily in recent years. Current vertical architectures, however, often suffer from a lack of parameter control, as they are limited to certain materials and processing techniques, making a controlled shift of, e.g., the transistor threshold voltage difficult. In this contribution, we present a vertical OFET (VOFET) operating in the inversion regime. By varying the thickness or doping concentration of a p-doped layer in an otherwise n-type VOFET, we are able to shift the threshold voltage in a controlled manner from 1.61 V (for a normal n-type VOFET) to 4.83 V (for the highest doping concentration of 50 mol. %). Furthermore, it is found that low doping concentrations of 20 mol. % can improve the Off state of the VOFET through reduction of the source-drain leakage current.

  13. Achieving effective control in cancer pain: a review of current guidelines.

    Science.gov (United States)

    Fielding, Flannery; Sanford, Tanya M; Davis, Mellar P

    2013-12-01

    Pain is one of the most common and distressing elements of suffering related to cancer and cancer treatment. Progress in cancer treatment means people will live longer with the sequelae of cancer and disease-directed treatments, and both the short- and long-term effects of opioid use must be considered. Skilled practitioners caring for individuals with cancer help to alleviate cancer-related pain by using the World Health Organization (WHO) step-wise approach to pain management as well as recently updated national and international guidelines. Current guidelines go beyond the unidimensional WHO model by addressing comprehensive assessment, pharmacological management of opioids and adverse effects associated with opioid use, the role of adjuvants, and the application of non-pharmacological treatments. By following current guidelines promoting a multifaceted approach to the management of cancer-related pain and advocating for patient-centered care, nurses are uniquely positioned to champion effective cancer pain management.

  14. Controlling nonlinear longitudinal space charge oscillations for high peak current bunch train generation

    Directory of Open Access Journals (Sweden)

    P. Musumeci

    2013-10-01

    Full Text Available The evolution of picosecond modulations of the longitudinal profile of an electron beam generated in an rf photoinjector is analyzed and optimized with the goal of obtaining high peak current electron bunch trains at very high frequencies (≥THz. Taking advantage of nonlinear longitudinal space charge forces, it is found that more than 500 A peak current 1 THz bunch trains can be generated using a standard 1.6 cell SLAC/UCLA/BNL rf gun. Postacceleration is used to freeze the longitudinal phase space dynamics after one half plasma oscillation. Applications range from tunable narrow bandwidth THz radiation generation to drivers for high frequency high gradient accelerators.

  15. Radioanalytical laboratory quality control: Current status at Tennessee Valley Authority's western area radiological laboratory

    International Nuclear Information System (INIS)

    Rogers, W.J.

    1986-01-01

    The Tennessee Valley Authority operates a laboratory for radiological analysis of nuclear plant environmental monitoring samples and also for analysis of environmental samples from uranium mining and milling decommissioning activities. The laboratory analyzes some 9,000 samples per year and employs approximately 20 people as analysts, sample collectors, and supervisory staff members. The laboratory is supported by a quality control section of four people involved in computer support, production of radioactive standards, quality control data assessment and reporting, and internal reviews of compliance. The entire laboratory effort is controlled by 60 written procedures or standards. An HP-1000 computer and data base software are used to schedule samples for collection, assign and schedule samples within the laboratory for preparation and analysis, calculate sample activity, review data, and report data outside the laboratory. Gamma spectroscopy systems with nine germanium detectors, an alpha spectroscopy system, five alpha/beta counters, two liquid scintillation counters, four beta-gamma coincidence systems, two sodium iodide single-channel systems, and four photomultipliers for counting Lucas cells are all employed. Each device has various calibration and quality control checks performed on it routinely. Logbooks and control charts are in use for each instrument

  16. Atopic dermatitis in children. A current algorithm for the disease treatment and control

    Directory of Open Access Journals (Sweden)

    D. V. Proshutinskaya

    2016-01-01

    Full Text Available The article discusses key aspects of the pathogenesis of atopic dermatitis and issues of the selection of pathogenetically substantiated therapy methods. The authors provide data on the efficient use of basic drugs used to treat dermatosis in children - topical glucocorticosteroids and calcineurin inhibitors. The authors also describe a current algorithm for using topical calcineurin inhibitors during the period of an exacerbation of atopic dermatitis and to prevent relapses.

  17. Transcranial direct current stimulation in refractory continuous spikes and waves during slow sleep: a controlled study

    DEFF Research Database (Denmark)

    Varga, Edina T; Terney, Daniella; Atkins, Mary D

    2011-01-01

    Cathodal transcranial direct current stimulation (tDCS) decreases cortical excitability. The purpose of the study was to investigate whether cathodal tDCS could interrupt the continuous epileptiform activity. Five patients with focal, refractory continuous spikes and waves during slow sleep were...... recruited. Cathodal tDCS and sham stimulation were applied to the epileptic focus, before sleep (1 mA; 20 min). Cathodal tDCS did not reduce the spike-index in any of the patients....

  18. Neural Network Computed Bootstrap Current for Real Time Control in DIII-D

    Science.gov (United States)

    Tema Biwole, Arsene; Smith, Sterling P.; Meneghini, Orso; Belli, Emily; Candy, Jeff

    2017-10-01

    In an effort to provide a fast and accurate calculation of the bootstrap current density for use as a constraint in real-time equilibrium reconstructions, we have developed a neural network (NN) non-linear regression of the NEO code calculated bootstrap current jBS. A new formulation for jBS in NEO allows for a determination of the coefficients on the density and temperature scale lengths. The new formulation reduces the number of inputs to the NN, and the number of output coefficients is 2 times the number of species (including electrons). The NN can reproduce the NEO and Sauter coefficients to a high degree of accuracy (bootstrap current density calculated in NEO has been used as a constraint in an offline equilibrium reconstruction for comparison to the NN calculation. The computational time of this method (μs) makes it ideal for real time calculation in DIII-D. Work supported by US DOE under DE-FC02-04ER54698, DE-FG2-95ER-54309, DE-SC 0012656, DE-FC02-06ER54873.

  19. Actively controlled current collector; Aktiv geregelter Stromabnehmer. Innovation fuer den schnellen Verkehr auf konventionellen Strecken

    Energy Technology Data Exchange (ETDEWEB)

    Mueller, C.

    2003-07-01

    Deutsche Bahn is presently endeavouring to further improve the interaction between the overhead wire and the current collectors on its locomotives and trainsets. The major factors behind this initiative are cost, quality and noise prevention. The outcome is the development of a completely new type of current collector for high-speed operation even on conventional track. Prototypes have meanwhile undergone practical trials on the 200 km/h line from Augsburg to Donauwoerth. The new current collector is a single-arm pantograph jointly developed by DB and Bombardier Transportation. (orig.) [German] Die Deutsche Bahn versucht derzeit, das Zusammenspiel von Oberleitung und den Stromabnehmern ihrer Lokomotiven und Triebzuege weiter zu verbessern. Kosten, Qualitaet und Laermschutz sind dabei die wesentlichen Gruende. Sie haben zur Entwicklung eines voellig neuen Stromabnehmer-Typus speziell fuer den Hochgeschwindigkeitsverkehr auch auf konventionellen Strecken gefuehrt. Auf der Tempo-200-Strecke von Augsburg nach Donauwoerth absolvierten jetzt Prototypen erste Praxis-Tests. Es handelt sich um aktiv geregelte, akustisch optimierte Einholmstromabnehmer, gemeinsam entwickelt von DB und Bombardier Transportation. (orig.)

  20. Adjoint optimization scheme for lower hybrid current rampup and profile control in Tokamak

    International Nuclear Information System (INIS)

    Litaudon, X.; Moreau, D.; Bizarro, J.P.; Hoang, G.T.; Kupfer, K.; Peysson, Y.; Shkarofsky, I.P.; Bonoli, P.

    1992-12-01

    The purpose of this work is to take into account and study the effect of the electric field profiles on the Lower Hybrid (LH) current drive efficiency during transient phases such as rampup. As a complement to the full ray-tracing / Fokker Planck studies, and for the purpose of optimization studies, we developed a simplified 1-D model based on the adjoint Karney-Fisch numerical results. This approach allows us to estimate the LH power deposition profile which would be required for ramping the current with prescribed rate, total current density profile (q-profile) and surface loop voltage. For rampup optimization studies, we can therefore scan the whole parameter space and eliminate a posteriori those scenarios which correspond to unrealistic deposition profiles. We thus obtain the time evolution of the LH power, minor radius of the plasma, volt-second consumption and total energy dissipated. Optimization can thus be performed with respect to any of those criteria. This scheme is illustrated by some numerical simulations performed with TORE-SUPRA and NET/ITER parameters. We conclude with a derivation of a simple and general scaling law for the flux consumption during the rampup phase

  1. Current tsetse control operations in Botswana and prospects for the future

    International Nuclear Information System (INIS)

    Allsopp, R.; Phillemon-Motsu, T.K.

    2000-01-01

    Several tsetse control methods have been used in Botswana over the past 70 years, ranging from bush clearing and selective game elimination, ground spraying with residual insecticides, aerial spraying with non-residual insecticides to the present odour-bait approach. Sequential aerial spraying, initially with endosulfan or mixtures of endosulfan with one of the synthetic pyrethroids, effectively controlled tsetse but did not achieve eradication. Aerial spraying was suspended in 1991 when the tsetse population had been reduced to a relatively small population along the Linyanti and Kwando rivers bordering Namibia and to an area of 4,000-5,000 km 2 in the Okavango Delta. After the 1991 aerial spraying operation the Tsetse Control Division switched to the use of odour-baited, insecticide-impregnated targets as well as localised, ground based thermal fogging. There has been no incidence of human and bovine trypanosomiasis since the mid-1980s and no significant insect population recovery since targets were introduced

  2. Balance control of grid currents for UPQC under unbalanced loads based on matching-ratio compensation algorithm

    DEFF Research Database (Denmark)

    Zhao, Xiaojun; Zhang, Chunjiang; Chai, Xiuhui

    2018-01-01

    In three-phase four-wire systems, unbalanced loads can cause grid currents to be unbalanced, and this may cause the neutral point potential on the grid side to shift. The neutral point potential shift will worsen the control precision as well as the performance of the threephase four-wire unified...... power quality conditioner (UPQC), and it also leads to unbalanced three-phase output voltage, even causing damage to electric equipment. To deal with unbalanced loads, this paper proposes a matching-ratio compensation algorithm (MCA) for the fundamental active component of load currents......, and by employing this MCA, balanced three-phase grid currents can be realized under 100% unbalanced loads. The steady-state fluctuation and the transient drop of the DC bus voltage can also be restrained. This paper establishes the mathematical model of the UPQC, analyzes the mechanism of the DC bus voltage...... fluctuations, and elaborates the interaction between unbalanced grid currents and DC bus voltage fluctuations; two control strategies of UPQC under three-phase stationary coordinate based on the MCA are given, and finally, the feasibility and effectiveness of the proposed control strategy are verified...

  3. An overview of the software architecture of the plasma position, current and density realtime controller of the FTU

    Energy Technology Data Exchange (ETDEWEB)

    Boncagni, Luca, E-mail: luca.boncagni@enea.it [EURATOM - ENEA Fusion Association, Frascati Research Centre, Division of Fusion Physics, Frascati, Rome (Italy); Vitelli, Riccardo; Carnevale, Daniele [Department of Computer Science, Systems and Production, University of Rome Tor Vergata, Rome (Italy); Galperti, Cristian, E-mail: galperti@ifp.cnr.it [EURATOM - ENEA - CNR Fusion Association, CNR-IFP via R. Cozzi 53, 20125 Milan (Italy); Artaserse, Giovanni [EURATOM - ENEA Fusion Association, Frascati Research Centre, Division of Fusion Physics, Frascati, Rome (Italy); Pucci, Daniele [Dipartimento Antonio Ruberti, Universit degli Studi di Roma La Sapienza, Rome (Italy)

    2014-03-15

    Highlights: • We implement the FTU PPCDC system using the MARTe Framework. • We describe how it is logically divided and how it works. • We show experimental examples to describe how it works. - Abstract: Experimental fusion devices requires flexible control systems with a modern architecture, which allows the controller to be distributed and modular. The aforementioned requirements are all fulfilled by MARTe, a multi-platform framework for the development of low-latency hard-real-time control system already used with success in many European machine, it was decided to adopt it as the basis of the new FTU Plasma Position Current Density Control (PPCDC) system and the other coupled realtime systems. The main rationale to revamp the FTU control system was to use new technologies and to easily test different control solutions. MARTe has been proved effective from both the points of view, being platform independent, and having a modular architecture which completely separate the control algorithms from the rest of the infrastructure. We report on the new controller deployed at FTU. In particular, after a brief introduction on the machine, we illustrate the structure of the feedback system, together with a detailed analysis and appropriate experimental examples, of the various GAMs (modules) which make up the controller.

  4. Real Time Hybrid Model Predictive Control for the Current Profile of the Tokamak à Configuration Variable (TCV

    Directory of Open Access Journals (Sweden)

    Izaskun Garrido

    2016-08-01

    Full Text Available Plasma stability is one of the obstacles in the path to the successful operation of fusion devices. Numerical control-oriented codes as it is the case of the widely accepted RZIp may be used within Tokamak simulations. The novelty of this article relies in the hierarchical development of a dynamic control loop. It is based on a current profile Model Predictive Control (MPC algorithm within a multiloop structure, where a MPC is developed at each step so as to improve the Proportional Integral Derivative (PID global scheme. The inner control loop is composed of a PID-based controller that acts over the Multiple Input Multiple Output (MIMO system resulting from the RZIp plasma model of the Tokamak à Configuration Variable (TCV. The coefficients of this PID controller are initially tuned using an eigenmode reduction over the passive structure model. The control action corresponding to the state of interest is then optimized in the outer MPC loop. For the sake of comparison, both the traditionally used PID global controller as well as the multiloop enhanced MPC are applied to the same TCV shot. The results show that the proposed control algorithm presents a superior performance over the conventional PID algorithm in terms of convergence. Furthermore, this enhanced MPC algorithm contributes to extend the discharge length and to overcome the limited power availability restrictions that hinder the performance of advanced tokamaks.

  5. An overview of the software architecture of the plasma position, current and density realtime controller of the FTU

    International Nuclear Information System (INIS)

    Boncagni, Luca; Vitelli, Riccardo; Carnevale, Daniele; Galperti, Cristian; Artaserse, Giovanni; Pucci, Daniele

    2014-01-01

    Highlights: • We implement the FTU PPCDC system using the MARTe Framework. • We describe how it is logically divided and how it works. • We show experimental examples to describe how it works. - Abstract: Experimental fusion devices requires flexible control systems with a modern architecture, which allows the controller to be distributed and modular. The aforementioned requirements are all fulfilled by MARTe, a multi-platform framework for the development of low-latency hard-real-time control system already used with success in many European machine, it was decided to adopt it as the basis of the new FTU Plasma Position Current Density Control (PPCDC) system and the other coupled realtime systems. The main rationale to revamp the FTU control system was to use new technologies and to easily test different control solutions. MARTe has been proved effective from both the points of view, being platform independent, and having a modular architecture which completely separate the control algorithms from the rest of the infrastructure. We report on the new controller deployed at FTU. In particular, after a brief introduction on the machine, we illustrate the structure of the feedback system, together with a detailed analysis and appropriate experimental examples, of the various GAMs (modules) which make up the controller

  6. SHAF for Mitigation of Current Harmonics Using p-q Method with PI and Fuzzy Controllers

    Directory of Open Access Journals (Sweden)

    A. K. Panda

    2011-08-01

    Full Text Available Commencing with incandescent light bulb, every load today creates harmonics. Unfortunately, these loads vary with respect to their amount of harmonic content and response to problems caused by harmonics. Issue of Harmonics are of a greater concern to engineers, building designers and in industrial applications because they do more than distort voltage waveforms, they can overheat the building wiring, cause nuisance tripping, overheat transformer units, and cause random end-user equipment failures. Thus power quality has become more and more serious with each passing day. As a result active power filter (APF gains much more attention due to excellent harmonic compensation. But still the performance of the active filter seems to be in contradictions with different control techniques. The main objective of this paper is to analyse shunt active filter with fuzzy and pi controllers. To carry out the analysis, we consider active and reactive power method (p-q. Extensive simulations were carried out; simulations were performed with balance, unbalanced and non sinusoidal conditions. Simulation results validate the dynamic behaviour of fuzzy logic controller over pi controller.

  7. Methods, systems and apparatus for controlling operation of two alternating current (AC) machines

    Science.gov (United States)

    Gallegos-Lopez, Gabriel [Torrance, CA; Nagashima, James M [Cerritos, CA; Perisic, Milun [Torrance, CA; Hiti, Silva [Redondo Beach, CA

    2012-02-14

    A system is provided for controlling two AC machines. The system comprises a DC input voltage source that provides a DC input voltage, a voltage boost command control module (VBCCM), a five-phase PWM inverter module coupled to the two AC machines, and a boost converter coupled to the inverter module and the DC input voltage source. The boost converter is designed to supply a new DC input voltage to the inverter module having a value that is greater than or equal to a value of the DC input voltage. The VBCCM generates a boost command signal (BCS) based on modulation indexes from the two AC machines. The BCS controls the boost converter such that the boost converter generates the new DC input voltage in response to the BCS. When the two AC machines require additional voltage that exceeds the DC input voltage required to meet a combined target mechanical power required by the two AC machines, the BCS controls the boost converter to drive the new DC input voltage generated by the boost converter to a value greater than the DC input voltage.

  8. Sea-level and ocean-current control on carbonate-platform growth, Maldives, Indian Ocean

    NARCIS (Netherlands)

    Betzler, C.; Fürstenau, J.; Lüdmann, T.; Hübscher, C.; Lindhorst, S.; Paul, A.; Reijmer, J.J.G.; Droxler, A.W.

    2013-01-01

    Multichannel high-resolution seismic and multibeam data were acquired from the Maldives-isolated carbonate platform in the Indian Ocean for a detailed characterization of the Neogene bank architecture of this edifice. The goal of the research is to decipher the controlling factors of platform

  9. Rationale and current perspective for early rhythm control therapy in atrial fibrillation

    DEFF Research Database (Denmark)

    Van Gelder, Isabelle C; Haegeli, Laurent M; Brandes, Axel

    2011-01-01

    Atrial fibrillation (AF) is the most common sustained arrhythmia and an important source for mortality and morbidity on a population level. Despite the clear association between AF and death, stroke, and other cardiovascular events, there is no evidence that rhythm control treatment improves outc...

  10. Trichogramma spp. (Hymenoptera: Trichogrammatidae) as biological control agents in the Philippines: history and current practice

    Science.gov (United States)

    Trichogramma parasitoids have long been recognized as important and viable biological control agents against lepidopteran pests of rice, corn and sugarcane in the Philippines. We describe the history of research and use of Trichogramma spp. in the Philippines in three main areas: 1) field surveys – ...

  11. Operators work reliability current control based on the psychological and physiological criteria

    International Nuclear Information System (INIS)

    Karpenko, A.V.; Burov, A.Yu.; Grigorus', A.G.; Kal'nish, V.V.; Kapshuk, A.P.; Grigor'yants, T.N.; Bobko, N.A.

    1984-01-01

    A possibility of developing highly sensitive criteria for assessment of mental working ability at the expense of profound automated analysis of available psychological and physiological criteria is disclosed; it is a precondition for developing operator is woAking ability control system not requiring additional personnel for its operation

  12. Elevated Hair Cortisol Levels among Heroin Addicts on Current Methadone Maintenance Compared to Controls

    Science.gov (United States)

    Yang, Jin; Li, Jifeng; Xu, Guanyi; Zhang, Jing; Chen, Zheng; Lu, Zuhong; Deng, Huihua

    2016-01-01

    Whether methadone maintenance treatment (MMT) can improve the basal function of the hypothalamic–pituitary–adrenal (HPA) axis, which is suppressed by long-term heroin consumption, is a matter of debate. The stress state and depression and anxiety symptoms may affect the basal activity of the HPA axis in MMT patients. However, the effect of psychological factors on HPA activity was not simultaneously controlled in previous studies. This study investigated differences in HPA basal activity between MMT patients and controls using psychological variables as covariates. The participants included 52 MMT patients and 41 age-matched, non-heroin-dependent controls. Psychological states were self-reported with the Perceived Stress Scale, Self-Rating Depression Scale and Self-Rating Anxiety Scale. The hair cortisol level was adopted as a biomarker of HPA basal activity and was determined with liquid chromatography tandem mass spectrometry. The results revealed that MMT patients had significantly higher hair cortisol levels than the controls (p0.05) when the perceived stress, depression and anxiety scores were used as covariates. We concluded that patients with long-term MMT showed higher basal activity of the HPA axis. The high chronic stress state and increase in depression and anxiety symptoms may mask the suppression effect of methadone on the HPA activity. PMID:27010803

  13. Transient voltage control of a DFIG-based wind power plant for suppressing overvoltage using a reactive current reduction loop

    Directory of Open Access Journals (Sweden)

    Geon Park

    2016-01-01

    Full Text Available This paper proposes a transient voltage control scheme of a doubly fed induction generator (DFIG-based wind power plant (WPP using a reactive current reduction loop to suppress the overvoltage at a point of interconnection (POI and DFIG terminal after a fault clearance. The change of terminal voltage of a DFIG is monitored at every predefined time period to detect the fault clearance. If the voltage change exceeds a set value, then the reactive current reduction loop reduces the reactive current reference in the DFIG controller using the step function. The reactive current injection of DFIGs in a WPP is rapidly reduced, and a WPP can rapidly suppress the overvoltage at a fault clearance because the reactive current reference is reduced. Using an electromagnetic transients program–released version (EMTP–RV simulator, the performance of the proposed scheme was validated for a model system comprising 20 units of a 5-MW DFIG considering various scenarios, such as fault and wind conditions. Test results show that the proposed scheme enables a WPP to suppress the overvoltage at the POI and DFIG terminal within a short time under grid fault conditions.

  14. Improving Control System Security through the Evaluation of Current Trends in Computer Security Research

    Energy Technology Data Exchange (ETDEWEB)

    Rolston

    2005-03-01

    At present, control system security efforts are primarily technical and reactive in nature. What has been overlooked is the need for proactive efforts, focused on the IT security research community from which new threats might emerge. Evaluating cutting edge IT security research and how it is evolving can provide defenders with valuable information regarding what new threats and tools they can anticipate in the future. Only known attack methodologies can be blocked, and there is a gap between what is known to the general security community and what is being done by cutting edge researchers --both those trying to protect systems and those trying to compromise them. The best security researchers communicate with others in their field; they know what cutting edge research is being done; what software can be penetrated via this research; and what new attack techniques and methodologies are being circulated in the black hat community. Standardization of control system applications, operating systems, and networking protocols is occurring at a rapid rate, following a path similar to the standardization of modern IT networks. Many attack methodologies used on IT systems can be ported over to the control system environment with little difficulty. It is extremely important to take advantage of the lag time between new research, its use on traditional IT networks, and the time it takes to port the research over for use on a control system network. Analyzing nascent trends in IT security and determining their applicability to control system networks provides significant information regarding defense mechanisms needed to secure critical infrastructure more effectively. This work provides the critical infrastructure community with a better understanding of how new attacks might be launched, what layers of defense will be needed to deter them, how the attacks could be detected, and how their impact could be limited.

  15. A robust predictive current controller for healthy and open-circuit faulty conditions of five-phase BLDC drives applicable for wind generators and electric vehicles

    International Nuclear Information System (INIS)

    Salehi Arashloo, Ramin; Salehifar, Mehdi; Romeral, Luis; Sala, Vicent

    2015-01-01

    Highlights: • Model predictive deadbeat control of generator stator phase currents. • Fault tolerant control of five-phase BLDC generator. • Control of stator phase currents under normal and open-circuit faulty conditions. • MATLAB simulation and experimental verification of proposed control method. • Verification of robustness and fast respond of proposed controlling method. - Abstract: Fault tolerant control of five-phase brushless direct current (BLDC) machines is gaining more importance in high-safety applications such as offshore wind generators and automotive industries. In many applications, traditional controllers (such as PI controllers) are used to control the stator currents under faulty conditions. These controllers have good performance with dc signals. However, in the case of missing one or two of the phases, appropriate reference currents of these machines have oscillatory dynamics both in phase- and synchronous-reference frames. Non-constant nature of these reference values requires the implication of fast current controllers. In this paper, model predictive deadbeat controllers are proposed to control the stator currents of five-phase BLDC machines under normal and faulty conditions. Open circuit fault is considered for both one and two stator phases, and the behaviour of proposed controlling method is evaluated. This evaluation is generally focused on first, sensitivity of proposed controlling method and second, its speed in following reference current values under transient states. Proposed method is simulated and is verified experimentally on a five-phase BLDC drive

  16. Public health argument to retain current UK national controls for tick and tapeworms under the Pet Travel Scheme.

    Science.gov (United States)

    Gover, L; Kirkbride, H; Morgan, D

    2011-02-01

    At present, the European Council is debating whether the current national controls under the Pet Travel Scheme (PETS), which aims to prevent the introduction of rabies and tapeworms or live ticks and their associated diseases into the United Kingdom (UK), should be harmonized amongst European Union (EU) Member States. There is a strong case to support the retention of control measures on human health grounds. Although many are aware of the implications of rabies infection, few realize the risk to the UK population if current tick and tapeworm controls under PETS were to be removed. If this were to occur, there is a risk that a number of diseases of human health importance may be introduced and become established in the UK. Such diseases include alveolar echinococcosis, tick borne encephalitis, tularaemia and Mediterranean spotted fever; all of which are found in other EU Member States but do not occur in the UK. These four diseases are responsible for a significant burden of disease in Europe, and current national controls under PETS have been highly effective in so far preventing their introduction into the UK. © 2009 Blackwell Verlag GmbH.

  17. Technical Study on Improvement of Endurance Capability of Limit Short-circuit Current of Charge Control SMART Meter

    Science.gov (United States)

    Li, W. W.; Du, Z. Z.; Yuan, R. m.; Xiong, D. Z.; Shi, E. W.; Lu, G. N.; Dai, Z. Y.; Chen, X. Q.; Jiang, Z. Y.; Lv, Y. G.

    2017-10-01

    Smart meter represents the development direction of energy-saving smart grid in the future. The load switch, one of the core parts of smart meter, should be of high reliability, safety and endurance capability of limit short-circuit current. For this reason, this paper discusses the quick simulation of relationship between attraction and counterforce of load switch without iteration, establishes dual response surface model of attraction and counterforce and optimizes the design scheme of load switch for charge control smart meter, thus increasing electromagnetic attraction and spring counterforce. In this way, this paper puts forward a method to improve the withstand capacity of limit short-circuit current.

  18. Decentralized energy management strategy based on predictive controllers for a medium voltage direct current photovoltaic electric vehicle charging station

    International Nuclear Information System (INIS)

    Torreglosa, Juan P.; García-Triviño, Pablo; Fernández-Ramirez, Luis M.; Jurado, Francisco

    2016-01-01

    Highlights: • Electric vehicle charging station supplied by photovoltaic, batteries and grid connection is analyzed. • The bus voltage is the key parameter for controlling the system by decentralized approach. • Decentralized control approach facilities the enlargement of the system. • Photovoltaic and battery systems are controlled by model predictive controllers. • Response by model predictive controllers improves that by PI controllers. - Abstract: The use of distributed charging stations based on renewable energy sources for electric vehicles has increased in recent years. Combining photovoltaic solar energy and batteries as energy storage system, directly tied into a medium voltage direct current bus, and with the grid support, results to be an interesting option for improving the operation and efficiency of electric vehicle charging stations. In this paper, an electric vehicle charging station supplied by photovoltaic solar panels, batteries and with grid connection is analysed and evaluated. A decentralized energy management system is developed for regulating the energy flow among the photovoltaic system, the battery and the grid in order to achieve the efficient charging of electric vehicles. The medium voltage direct current bus voltage is the key parameter for controlling the system. The battery is controlled by a model predictive controller in order to keep the bus voltage at its reference value. Depending on the state-of-charge of the battery and the bus voltage, the photovoltaic system can work at maximum power point tracking mode or at bus voltage sustaining mode, or even the grid support can be needed. The results demonstrate the proper operation and energy management of the electric vehicle charging station under study.

  19. Integrated Application of Active Controls (IAAC) technology to an advanced subsonic transport project: Current and advanced act control system definition study, volume 1

    Science.gov (United States)

    Hanks, G. W.; Shomber, H. A.; Dethman, H. A.; Gratzer, L. B.; Maeshiro, A.; Gangsaas, D.; Blight, J. D.; Buchan, S. M.; Crumb, C. B.; Dorwart, R. J.

    1981-01-01

    An active controls technology (ACT) system architecture was selected based on current technology system elements and optimal control theory was evaluated for use in analyzing and synthesizing ACT multiple control laws. The system selected employs three redundant computers to implement all of the ACT functions, four redundant smaller computers to implement the crucial pitch-augmented stability function, and a separate maintenance and display computer. The reliability objective of probability of crucial function failure of less than 1 x 10 to the -9th power per flight of 1 hr can be met with current technology system components, if the software is assumed fault free and coverage approaching 1.0 can be provided. The optimal control theory approach to ACT control law synthesis yielded comparable control law performance much more systematically and directly than the classical s-domain approach. The ACT control law performance, although somewhat degraded by the inclusion of representative nonlinearities, remained quite effective. Certain high-frequency gust-load alleviation functions may require increased surface rate capability.

  20. Network communication for remote technology and NDT controls on current nuclear power plants

    International Nuclear Information System (INIS)

    Capitaine, A.

    2001-01-01

    Among the most important targets for ''UTILITIES'' are to increase nuclear power plant availability and reduce the workers dosimetry. A possible way to reach these targets is to reduce the duration of the refueling period and to limit the number of operators in the work areas It is necessary to use remote technology and to provide much equipment to support the main activities during refueling. Remote technology is a possible solution to remove operators from the maintenance area. The main activities concerned are the NDT inspection on the primary components and fuel handling system. Recent progress on remote technology made by the electronic industry and network communication has increased their capacities. It is easier now to use them, and more and more people are familiar with these technologies. Internet, manufacturing, supervision, and surgery use these technologies. Now it seems appropriate to examine these technologies for current maintenance in nuclear plants. Remote technologies and communication network can help to solve current difficulties in the maintenance field and dosimetry limits. For a long time, many people thought that the cost and the difficulty of applying new technologies would be not extremely expensive, but this is no longer the case. Now with the first feed back we can show that these technologies are a good answer for increased availability and reduction of dosimetry. (author)

  1. NASA's Beachside Corrosion Test Site and Current Environmentally Friendly Corrosion Control Initiatives

    Science.gov (United States)

    Russell, Richard W.; Calle, Luz Marina; Johnston, Frederick; Montgomery, Eliza L.; Curran, Jerome P.; Kolody, Mark R.

    2013-01-01

    NASA began corrosion studies at the Kennedy Space Center (KSC) in 1966 during the Gemini/Apollo Programs with the evaluation of long-term corrosion protective coatings for carbon steel. KSC's Beachside Corrosion Test Site (BCTS), which has been documented by the American Society of Materials (ASM) as one of the most corrosive, naturally occurring, environments in the world, was established at that time. With the introduction of the Space Shuttle in 1981, the already highly corrosive conditions at the launch pad were rendered even more severe by the acid ic exhaust from the solid rocket boosters. In the years that followed, numerous studies have identified materials, coatings, and maintenance procedures for launch hardware and equipment exposed to the highly corrosive environment at the launch pad. This paper presents a historical overview of over 45 years of corrosion and coating evaluation studies and a description of the BCTS's current capabilities. Additionally, current research and testing programs involving chromium free coatings, environmentally friendly corrosion preventative compounds, and alternates to nitric acid passivation will be discussed.

  2. Computation of stationary 3D halo currents in fusion devices with accuracy control

    Science.gov (United States)

    Bettini, Paolo; Specogna, Ruben

    2014-09-01

    This paper addresses the calculation of the resistive distribution of halo currents in three-dimensional structures of large magnetic confinement fusion machines. A Neumann electrokinetic problem is solved on a geometry so complicated that complementarity is used to monitor the discretization error. An irrotational electric field is obtained by a geometric formulation based on the electric scalar potential, whereas three geometric formulations are compared to obtain a solenoidal current density: a formulation based on the electric vector potential and two geometric formulations inspired from mixed and mixed-hybrid Finite Elements. The electric vector potential formulation is usually considered impractical since an enormous computing power is wasted by the topological pre-processing it requires. To solve this challenging problem, we present novel algorithms based on lazy cohomology generators that enable to save orders of magnitude computational time with respect to all other state-of-the-art solutions proposed in literature. Believing that our results are useful in other fields of scientific computing, the proposed algorithm is presented as a detailed pseudocode in such a way that it can be easily implemented.

  3. Current status of the radiation technology and quality control for radiation processing in Latin America

    International Nuclear Information System (INIS)

    Miranda, Enrique Francisco Prietro

    2013-01-01

    The use of the radiation technology has gained acceptance in various regions of the world, where studies estimated that the installed capacity increases at a rate of 6 % per year and Latin America is part of this increase, due the advantages of this process when it is employed for the food preservation, sterilization of medical pharmaceutical material and to control the insect pests. This paper shows the art state of the application of Radiation Technology in Latin America, as well as the technological characteristics of the most gamma irradiation facilities and minor number the electron beam accelerator facilities, the types of irradiated products, state of the Quality Management System and the Dosimetric Systems used in the Radiation Processing Control in the Region. (author)

  4. Health, human rights, and malaria control: historical background and current challenges.

    Science.gov (United States)

    Brentlinger, Paula E

    2006-01-01

    Malaria, a parasitic infection, causes hundreds of millions of disease episodes and more than a million deaths every year, nearly all of them occurring in the poorer and more vulnerable sectors of the world's developing countries. In spite of the great burden of suffering caused by malaria, the human rights implications of this disease have not been well described. This article summarizes important associations between the spread of malaria and human rights abuses (such as those associated with slavery and armed conflict) and between poverty, socio-economic inequity, and access to malaria-control measures. The author concludes that malaria control merits inclusion as a core element in global strategies to achieve progressive realization of the right to health.

  5. Implementation of the Framework Convention on Tobacco Control in Africa: Current Status of Legislation

    Directory of Open Access Journals (Sweden)

    Jacqueline Tumwine

    2011-11-01

    Full Text Available Objective: To describe, as of July 2011, the status of tobacco control legislation in Africa in three key areas of the Framework Convention on Tobacco Control (FCTC—(1 Protection from exposure to tobacco smoke, (2 Packaging and labelling of tobacco products, and (3 Tobacco advertising, promotion and sponsorship. Methods: Review and analysis of tobacco control legislation in Africa, media reports, journal articles, tobacco industry documents and data published in the 2011 WHO Report on the Global Tobacco Epidemic. Results: Modest progress in FCTC implementation in Africa with many countries having legislation or policies on the protection from exposure to tobacco smoke, however, only a handful of countries meet the standards of the FCTC Article 8 and its Guidelines particularly with regards to designated smoking areas. Little progress on packaging and labelling of tobacco products, with few countries having legislation meeting the minimum standards of the FCTC Article 11 and its Guidelines. Mauritius is the only African country with graphic or pictorial health warnings in place and has the largest warning labels in Africa. Slightly better progress in banning tobacco advertising, promotion and sponsorship has been shown by African countries, although the majority of legislation falls short of the standards of the FCTC Article 13 and its Guidelines. Despite their efforts, African countries’ FCTC implementation at national level has not matched the strong regional commitment demonstrated during the FCTC treaty negotiations. Conclusion: This study highlights the need for Africa to step up efforts to adopt and implement effective tobacco control legislation that is fully compliant with the FCTC. In order to achieve this, countries should prioritise resources for capacity building for drafting strong FCTC compliant legislation, research to inform policy and boost political will, and countering the tobacco industry which is a major obstacle to FCTC

  6. Implementation of the framework convention on tobacco control in Africa: current status of legislation.

    Science.gov (United States)

    Tumwine, Jacqueline

    2011-11-01

    To describe, as of July 2011, the status of tobacco control legislation in Africa in three key areas of the Framework Convention on Tobacco Control (FCTC)-(1) Protection from exposure to tobacco smoke, (2) Packaging and labelling of tobacco products, and (3) Tobacco advertising, promotion and sponsorship. Review and analysis of tobacco control legislation in Africa, media reports, journal articles, tobacco industry documents and data published in the 2011 WHO Report on the Global Tobacco Epidemic. Modest progress in FCTC implementation in Africa with many countries having legislation or policies on the protection from exposure to tobacco smoke, however, only a handful of countries meet the standards of the FCTC Article 8 and its Guidelines particularly with regards to designated smoking areas. Little progress on packaging and labelling of tobacco products, with few countries having legislation meeting the minimum standards of the FCTC Article 11 and its Guidelines. Mauritius is the only African country with graphic or pictorial health warnings in place and has the largest warning labels in Africa. Slightly better progress in banning tobacco advertising, promotion and sponsorship has been shown by African countries, although the majority of legislation falls short of the standards of the FCTC Article 13 and its Guidelines. Despite their efforts, African countries' FCTC implementation at national level has not matched the strong regional commitment demonstrated during the FCTC treaty negotiations. This study highlights the need for Africa to step up efforts to adopt and implement effective tobacco control legislation that is fully compliant with the FCTC. In order to achieve this, countries should prioritise resources for capacity building for drafting strong FCTC compliant legislation, research to inform policy and boost political will, and countering the tobacco industry which is a major obstacle to FCTC implementation in Africa.

  7. Analgesia for pain control during extracorporeal shock wave lithotripsy: Current status

    Directory of Open Access Journals (Sweden)

    Narmada P Gupta

    2008-01-01

    Conclusion: The ideal analgesic, offering optimal pain control, minimal side effects, and cost-effectiveness is still elusive. Opioids administered using various techniques, provide effective analgesia, but require active monitoring of patient for potential adverse effects. Combination therapy (oral NSAID and occlusive dressing of EMLA, DMSO with lidocaine offers an effective alternative mode for achieving analgesia with minimal morbidity. This therapy avoids the need for general anesthesia, injectable analgesics, and opioids along with their side effects.

  8. Programmable controller with overcurrent latch for constant primary peak current in capacitor-charging FET switcher for Nova

    International Nuclear Information System (INIS)

    Mihalka, A.M.

    1983-01-01

    New switching power supplies were designed for the 10 mm laser amplifiers in the Nova Master Oscillator Room. The flashlamp supply must be repratable. Therefore, we designed a constant current, linearly charging power supply. Since it is a capacitor, the load varies throughout the charge cycle. At first the load is great, and di/dt of load current is at a maximum. As the capacitor charges the initial conditions for each cycle change, the power supply in effect sees a smaller capacitance, and di/dt decreases. We need a way of gradually increasing the on-time of the current pulses so that the transistors in the power bridge are turned off when they reach their maximum peak current. The normal current sense response of the control chip is not fast enough to be useful for our application. The deadtime, or the time that all the bridge transistors are turned off, is fixed so that as the pulse width varies so does the period. We end up with a constant peak current, switching power supply whose frequency varies from 50 khz to 20 khz. Finally, an overcurrent latch protects the transistors from bridge or transformer faults. The circuit is described and results are shown

  9. Low Dark-Current, High Current-Gain of PVK/ZnO Nanoparticles Composite-Based UV Photodetector by PN-Heterojunction Control

    Directory of Open Access Journals (Sweden)

    Sang-Won Lee

    2016-01-01

    Full Text Available We propose a solution-processable ultraviolet (UV photodetector with a pn-heterojunction hybrid photoactive layer (HPL that is composed of poly-n-vinylcarbazole (PVK as a p-type polymer and ZnO nanoparticles (NPs as an n-type metal oxide. To observe the effective photo-inducing ability of the UV photodetector, we analyzed the optical and electrical properties of HPL which is controlled by the doping concentration of n-type ZnO NPs in PVK matrix. Additionally, we confirmed that the optical properties of HPL dominantly depend on the ZnO NPs from the UV-vis absorption and the photoluminescence (PL spectral measurements. This HPL can induce efficient charge transfer in the localized narrow pn-heterojunction domain and increases the photocurrent gain. It is essential that proper doping concentration of n-type ZnO NPs in polymer matrix is obtained to improve the performance of the UV photodetector. When the ZnO NPs are doped with the optimized concentration of 3.4 wt.%, the electrical properties of the photocurrent are significantly increased. The ratio of the photocurrent was approximately 103 higher than that of the dark current.

  10. Spin current

    CERN Document Server

    Valenzuela, Sergio O; Saitoh, Eiji; Kimura, Takashi

    2012-01-01

    In a new branch of physics and technology called spin-electronics or spintronics, the flow of electrical charge (usual current) as well as the flow of electron spin, the so-called 'spin current', are manipulated and controlled together. This book provides an introduction and guide to the new physics and application of spin current.

  11. Dynamic Stability Enhancement and Power Flow Control of a Hybrid Wind and Marine-Current Farm Using SMES

    DEFF Research Database (Denmark)

    Wang, Li; Chen, Shiang-Shong; Lee, Wei-Jen

    2009-01-01

    be concluded from the simulated results that the proposed SMES unit combined with the designed damping controller is very effective to stabilize the studied combined WF and MCF under various wind speeds. The inherent fluctuations of the injected active power and reactive power of the WF and MCF to the power......This paper presents a control scheme based on a superconducting magnetic energy storage (SMES) unit to achieve both power flow control and damping enhancement of a novel hybrid wind and marine-current farm (MCF) connected to a large power grid. The performance of the studied wind farm (WF...... under different operating conditions. A frequency-domain approach based on a linearized system model using eigen techniques and a time-domain scheme based on a nonlinear system model subject to disturbance conditions are both employed to validate the effectiveness of the proposed control scheme. It can...

  12. Particular treatments in Eddy current technique. Application to the control of corrugated tubes

    International Nuclear Information System (INIS)

    1982-11-01

    When the testing of a given product shows that, owing to a particular shape of this product or to its environment, disturbing effects can hide the presence of harmful defects, use must be made of testing artifices or particular treatments enabling an efficient examination to be made. On this score, many eddy current problems are solved by means of the following processes: - use of specific sensors adapted to the geometry of the product, - spectral analysis of the analog results of analyses, - combination of the results of analyses obtained simultaneously at different frequencies (multifrequency techniques). An example of an application is given for corrugated tubes achieved by hollow and helical milling of smooth tubes [fr

  13. [Diphtheria in the military forces: lessons and current status of prophylaxis, prospects of epidemiological control process].

    Science.gov (United States)

    Belov, A B; Ogarkov, P I

    2014-01-01

    We analyzed the epidemiological situation of diphtheria in the world and in Russia and experience of mass vaccination of military personnel and civil population with diphtheria toxoid for the last 50 years. Early diagnosis of diphtheria in military personnel has a prognostic value. Authors described the peculiarities of epidemiological process of diphtheria in military personnel in 80-90 years of 20th century and organizational aspects of mass vaccination with diphtheria toxoid. Authors analyzed current problems of epidemiology and prophylaxis of diphtheria in military personnel and civil population and possible developments. According to long-term prognosis authors mentioned the increase of morbidity and came to conclusion that it is necessary enhance the epidemiological surveillance. Authors presented prospect ways of improvement of vaccination and rational approaches to immunization of military personnel under positive long-term epidemiological situation.

  14. Current status of control of radiation sources and radioactive materials in the United Republic of Tanzania

    International Nuclear Information System (INIS)

    Nyaruba, M.M.; Mompome, W.K.

    2001-01-01

    A Protection from Radiation Act was enacted in Tanzania in 1983 to regulate the use of ionizing radiation and protect people against its danger. The Act established a regulatory authority known as National Radiation Commission (NRC), which is the corporate body to enforce the law and regulations. From the beginning of 2000, the NRC has kept inventory of 200 and 324 radiation installations, and radiation sources and radioactive materials in the country, respectively; and has provided personnel monitoring services to 665 radiation workers. However, due to the trade liberalization that is currently being experienced in the country, the increase in the number of radiation practices is observed yearly. To cope with the situation, the whole system of notification, authorization, registration and licensing needs to be improved. The improvement has now started by amending the existing Protection from Radiation Act. (author)

  15. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters

    Directory of Open Access Journals (Sweden)

    Ali Algaddafi

    2017-01-01

    Full Text Available Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.

  16. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters.

    Science.gov (United States)

    Algaddafi, Ali; Altuwayjiri, Saud A; Ahmed, Oday A; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances.

  17. Optimization Based Shunt APF Controller to Mitigate Reactive Power, Burden of Neutral Conductor, Current Harmonics and Improve cosɸ

    Directory of Open Access Journals (Sweden)

    P. Anjana

    2017-03-01

    Full Text Available This paper presents a Modified Gravitational Search Algorithm (MGSA to improve the performance of PI controller in varying load condition. The proposed approach is capable of mitigating reactive power, neutral current, source current THD and significant improvement in power factor nearly unity (0.997. The DC link voltage across the capacitor is controlled by PI controller which is deciding the performance of shunt APF. Hence, the robust optimization technique based integral time square error (ITSE with consideration of weight factor (α & β, maximum overshoot ((|(∆_Ve ̅〖(n〗_max | and setling time t_s-t_0, is providing the optimum solution of Kp & Ki. The robustness of proposed objective function and algorithm compared with GSA based three other error criterion techniques. The efficiency of the proposed controller has been tested over nonlinear and unbalance loading condition. The performance of ITSE based MGSA-PI controller is batter then other three error criterion techniques. The values of THD are below the mark of 5% specified in IEEE-519 standard.

  18. An Optimal Current Controller Design for a Grid Connected Inverter to Improve Power Quality and Test Commercial PV Inverters

    Science.gov (United States)

    Altuwayjiri, Saud A.; Ahmed, Oday A.; Daho, Ibrahim

    2017-01-01

    Grid connected inverters play a crucial role in generating energy to be fed to the grid. A filter is commonly used to suppress the switching frequency harmonics produced by the inverter, this being passive, and either an L- or LCL-filter. The latter is smaller in size compared to the L-filter. But choosing the optimal values of the LCL-filter is challenging due to resonance, which can affect stability. This paper presents a simple inverter controller design with an L-filter. The control topology is simple and applied easily using traditional control theory. Fast Fourier Transform analysis is used to compare different grid connected inverter control topologies. The modelled grid connected inverter with the proposed controller complies with the IEEE-1547 standard, and total harmonic distortion of the output current of the modelled inverter has been just 0.25% with an improved output waveform. Experimental work on a commercial PV inverter is then presented, including the effect of strong and weak grid connection. Inverter effects on the resistive load connected at the point of common coupling are presented. Results show that the voltage and current of resistive load, when the grid is interrupted, are increased, which may cause failure or damage for connecting appliances. PMID:28540362

  19. Control and management of congenital Chagas disease in Europe and other non-endemic countries: current policies and practices.

    Science.gov (United States)

    Soriano-Arandes, Antoni; Angheben, Andrea; Serre-Delcor, Nuria; Treviño-Maruri, Begoña; Gómez I Prat, Jordi; Jackson, Yves

    2016-05-01

    Identifying pregnant women infected with Trypanosoma cruzi is one of the major challenges for preventing and controlling Chagas disease (CD) in non-endemic countries. The aim of this paper was to perform a policy evaluation of the current practices of congenital Chagas disease (CCD) control in non-endemic countries and to propose specific targets for enhanced interventions to tackle this emerging health problem outside the endemic areas of Latin America. We conducted a mixed method review of CCD policy strategies by searching the literature in the PubMed, Google Scholar and the World Health Organization (WHO) databases using the key terms 'CCD', 'paediatric Chagas disease' and 'non-endemic countries'; as free text and combined as one phrase to increase the search sensitivity. Reviews, recommendations, guidelines and control/surveillance programme reports were included. Of 427 CCD papers identified in non-endemic countries, 44 matched the inclusion. Although local programmes were launched in different countries with large numbers of Latin American immigrants, there were considerable disparities in terms of the programmes' distribution, delivery, integration and appropriated CCD control strategies. Moreover, Catalonia, Spain is the only region/country with an established systematic monitoring of CCD in pregnant women from Latin American countries. Given the worldwide dissemination of CD, the nature of its vertical transmission, and the gaps of the current strategies in non-endemic countries, there is an urgent need to standardise, expand and reinforce the control measures against CCD transmission. © 2016 John Wiley & Sons Ltd.

  20. Design, construction and installation of the electromechanical components of the current control of filament of the Pelletron Electron Accelerator

    International Nuclear Information System (INIS)

    Aguilar J, R.A.; Valdovinos A, M.; Lopez V, H.

    1985-01-01

    For the operation of the Pelletron electron accelerator is required to have control of the filament current. For it was designed, built and installed an electromechanical system located in the Acceleration Unit inside the Accelerator tank and operated from the Control console. All the components located inside the tank operated under the following conditions: Pressure: until 7.03 Kg/cm 2 ; High voltage: 10 6 V (only the insulating arrow); Atmosphere: mixture of N 2 and CO 2 or SF 6 . (Author)