WorldWideScience

Sample records for current control means

  1. Lower hybrid wave accessibility as a means for current profile control

    International Nuclear Information System (INIS)

    Briffod, G.; Gormezano, C.; Parlange, F.; Van Houtte, D.

    1986-01-01

    Powerful ICRH experiments on JET and Neutral Beam Injection of various species on TFTR have recently confirmed the insensitivity of the temperature and safety factor profile shapes to the heating profile and the important role played by the sawtooth activity on the overall performances. In order to overcome these limitations, we propose in this paper, in a Tokamak operating at constant plasma current: to control the resistive part of the current by driving an H.F. current by Lower Hybrid Wave. To act on the current profile, with the constraint that q(o) > 1 by controlling the wave penetration. Constant plasma current Tokamak discharges in which a part of the current is driven by L.H.W. have been extensively studied on PETULA and this mode of operation has proven to be very efficient in stabilizing the sawtooth and M.H.D. activity

  2. Current means for plasma diagnostics and their application for materials and environment control. Materials of IV Russian seminar

    International Nuclear Information System (INIS)

    2003-01-01

    The collection contains reports made at the Fourth Russian seminar Current means of plasma diagnostics and their application for materials and environment control. The seminar took place in Moscow, November 12-14, 2003. The content of the collection covers both questions of plasma diagnostics in thermonuclear reactors and problems of diagnostics of pulsed and stationary gas discharges in research and technological installations. The reports on plasma diagnostics applied for some tasks of medicine and environment control are presented [ru

  3. Control of the electrode metal transfer by means of the welding current pulse generator

    Science.gov (United States)

    Knyaz'kov, A.; Pustovykh, O.; Verevkin, A.; Terekhin, V.; Shachek, A.; Knyaz'kov, S.; Tyasto, A.

    2016-04-01

    The paper presents a generator of welding current pulses to transfer an electrode metal into the molten pool. A homogeneous artificial line is used to produce near rectangular pulses. The homogeneous artificial line provides the minimum heat input with in the pulse to transfer the electrode metal, and it significantly decreases the impact of disturbances affecting this transfer. The pulse frequency does not exceed 300 Hz, and the duration is 0.6 ÷ 0.9 ms.

  4. Means and ends of control

    DEFF Research Database (Denmark)

    Lind, Morten

    2004-01-01

    assumptions. Means-end analysis also lacks a proper definition of the control concept. It is proposed that control is defined as a binary relation that assign functional roles to subsystems. This control concept leads to distinct but entangled process and control hierarchies. It is argued that the problems...

  5. Controlling Access to Suicide Means

    Directory of Open Access Journals (Sweden)

    Miriam Iosue

    2011-12-01

    Full Text Available Background: Restricting access to common means of suicide, such as firearms, toxic gas, pesticides and other, has been shown to be effective in reducing rates of death in suicide. In the present review we aimed to summarize the empirical and clinical literature on controlling the access to means of suicide. Methods: This review made use of both MEDLINE, ISI Web of Science and the Cochrane library databases, identifying all English articles with the keywords “suicide means”, “suicide method”, “suicide prediction” or “suicide prevention” and other relevant keywords. Results: A number of factors may influence an individual’s decision regarding method in a suicide act, but there is substantial support that easy access influences the choice of method. In many countries, restrictions of access to common means of suicide has lead to lower overall suicide rates, particularly regarding suicide by firearms in USA, detoxification of domestic and motor vehicle gas in England and other countries, toxic pesticides in rural areas, barriers at jumping sites and hanging, by introducing “safe rooms” in prisons and hospitals. Moreover, decline in prescription of barbiturates and tricyclic antidepressants (TCAs, as well as limitation of drugs pack size for paracetamol and salicylate has reduced suicides by overdose, while increased prescription of SSRIs seems to have lowered suicidal rates. Conclusions: Restriction to means of suicide may be particularly effective in contexts where the method is popular, highly lethal, widely available, and/or not easily substituted by other similar methods. However, since there is some risk of means substitution, restriction of access should be implemented in conjunction with other suicide prevention strategies.

  6. CMOS current controlled fully balanced current conveyor

    International Nuclear Information System (INIS)

    Wang Chunhua; Zhang Qiujing; Liu Haiguang

    2009-01-01

    This paper presents a current controlled fully balanced second-generation current conveyor circuit (CF-BCCII). The proposed circuit has the traits of fully balanced architecture, and its X-Y terminals are current controllable. Based on the CFBCCII, two biquadratic universal filters are also proposed as its applications. The CFBCCII circuits and the two filters were fabricated with chartered 0.35-μm CMOS technology; with ±1.65 V power supply voltage, the total power consumption of the CFBCCII circuit is 3.6 mW. Comparisons between measured and HSpice simulation results are also given.

  7. Means for driving control rod

    International Nuclear Information System (INIS)

    Sato, Haruo; Sasaki, Masayoshi.

    1974-01-01

    Object: To enable wire rope to be readily removed from guide pulleys for the inspection or replacement of control rods. Structure: A pair of guide pulleys disposed to oppose each other are provided on their periphery with respective notches which are arranged in a staggered fashion. In this way, the rope is made to be removed from the notches for inspection of the control rod or for other purposes. (Kamimura, M.)

  8. Estimates on the mean current in a sphere of plasma

    International Nuclear Information System (INIS)

    Nunez, Manuel

    2003-01-01

    Several turbulent dynamo models predict the concentration of the magnetic field in chaotic plasmas in sheets with the field vector pointing alternatively in opposite directions, which should produce strong current sheets. It is proved that if the plasma is contained in a rigid sphere with perfectly conducting boundary the geometry of these sheets must be balanced so that the mean current remains essentially bounded by the Coulomb gauged mean vector potential of the field. This magnitude remains regular even for the sharp field variations expected in a chaotic flow. For resistive plasmas the same arguments imply that the contribution to the total current of the regions near the boundary compensates the current of the central part of the sphere

  9. X-ray tube current control

    International Nuclear Information System (INIS)

    Dupuis, W.A.; Resnick, T.A.

    1982-01-01

    A closed loop feedback system for controlling the current output of an x-ray tube. The system has circuitry for improving the transient response and stability of the x-ray tube current over a substantial nonlinear portion of the tube current production characteristic. The system includes a reference generator for applying adjustable step function reference signals representing desired tube currents. The system also includes means for instantaneous sensing of actual tube current. An error detector compares the value of actual and reference tube current and produces an error signal as a function of their difference. The system feedback loop includes amplification circuitry for controlling x-ray tube filament dc voltage to regulate tube current as a function of the error signal value. The system also includes compensation circuitry, between the reference generator and the amplification circuitry, to vary the loop gain of the feedback control system as a function of the reference magnitude

  10. Mean Field Type Control with Congestion

    Energy Technology Data Exchange (ETDEWEB)

    Achdou, Yves, E-mail: achdou@ljll.univ-paris-diderot.fr; Laurière, Mathieu [Univ. Paris Diderot, Sorbonne Paris Cité, Laboratoire Jacques-Louis Lions, UMR 7598, UPMC, CNRS (France)

    2016-06-15

    We analyze some systems of partial differential equations arising in the theory of mean field type control with congestion effects. We look for weak solutions. Our main result is the existence and uniqueness of suitably defined weak solutions, which are characterized as the optima of two optimal control problems in duality.

  11. Proportional-Integral-Resonant AC Current Controller

    Directory of Open Access Journals (Sweden)

    STOJIC, D.

    2017-02-01

    Full Text Available In this paper an improved stationary-frame AC current controller based on the proportional-integral-resonant control action (PIR is proposed. Namely, the novel two-parameter PIR controller is applied in the stationary-frame AC current control, accompanied by the corresponding parameter-tuning procedure. In this way, the proportional-resonant (PR controller, common in the stationary-frame AC current control, is extended by the integral (I action in order to enable the AC current DC component tracking, and, also, to enable the DC disturbance compensation, caused by the voltage source inverter (VSI nonidealities and by nonlinear loads. The proposed controller parameter-tuning procedure is based on the three-phase back-EMF-type load, which corresponds to a wide range of AC power converter applications, such as AC motor drives, uninterruptible power supplies, and active filters. While the PIR controllers commonly have three parameters, the novel controller has two. Also, the provided parameter-tuning procedure needs only one parameter to be tuned in relation to the load and power converter model parameters, since the second controller parameter is directly derived from the required controller bandwidth value. The dynamic performance of the proposed controller is verified by means of simulation and experimental runs.

  12. Magnetoelectric control of spin currents

    Energy Technology Data Exchange (ETDEWEB)

    Gómez, J. E.; Vargas, J. M.; Avilés-Félix, L.; Butera, A. [Centro Atómico Bariloche, Instituto de Nanociencia y Nanotecnología (CNEA) and Conicet, 8400 Bariloche, Río Negro (Argentina)

    2016-06-13

    The ability to control the spin current injection has been explored on a hybrid magnetoelectric system consisting of a (011)-cut ferroelectric lead magnesium niobate-lead titanate (PMNT) single crystal, a ferromagnetic FePt alloy, and a metallic Pt. With this PMNT/FePt/Pt structure we have been able to control the magnetic field position or the microwave excitation frequency at which the spin pumping phenomenon between FePt and Pt occurs. We demonstrate that the magnetoelectric heterostructure operating in the L-T (longitudinal magnetized-transverse polarized) mode couples the PMNT crystal to the magnetostrictive FePt/Pt bilayer, displaying a strong magnetoelectric coefficient of ∼140 Oe cm kV{sup −1}. Our results show that this mechanism can be effectively exploited as a tunable spin current intensity emitter and open the possibility to create an oscillating or a bistable switch to effectively manipulate spin currents.

  13. Tokamak plasma current disruption infrared control system

    International Nuclear Information System (INIS)

    Kugel, H.W.; Ulrickson, M.

    1987-01-01

    This patent describes a device for magnetically confining a plasma driven by a plasma current and contained within a toroidal vacuum chamber, the device having an inner toroidal limiter on an inside wall of the vacuum chamber and an arrangement for the rapid prediction and control in real time of a major plasma disruption. The arrangement is described which includes: scanning means sensitive to infrared radiation emanating from within the vacuum chamber, the infrared radiation indicating the temperature along a vertical profile of the inner toroidal limiter. The scanning means is arranged to observe the infrared radiation and to produce in response thereto an electrical scanning output signal representative of a time scan of temperature along the vertical profile; detection means for analyzing the scanning output signal to detect a first peaked temperature excursion occurring along the profile of the inner toroidal limiter, and to produce a detection output signal in repsonse thereto, the detection output signal indicating a real time prediction of a subsequent major plasma disruption; and plasma current reduction means for reducing the plasma current driving the plasma, in response to the detection output signal and in anticipation of a subsequent major plasma disruption

  14. Deconstructing The Current Construction Of Mow: 'Meaning Of Work ...

    African Journals Online (AJOL)

    ‟. It is argued that MOW could be ... This paper calls for debate on the ontological (the nature) and teleological (the purpose) base of the concept „work‟, its meaning in society and application in work psychology. Such debate would inform the ...

  15. [Gene doping--current possibilities, risks and means of prevention].

    Science.gov (United States)

    Pleger, N; Vitzthum, K; Schöffel, N; Quarcoo, D; Uibel, S; Groneberg, D A

    2011-03-01

    With the advances in gene therapy fears of an abuse in sports arise. The WADA's definition of the term strictly differentiates between gene doping and gene therapy. There are in vivo and ex vivo practices to manipulate the different phases of gene expression in the organism, with viral vectors being looked upon as the most efficient ones. IGF-1, PPARδ, MSTN and EPO play the most important roles in today's scientific research. Their potential was proven in various animal studies, showing a significant improvement of performances. Potential risks for human users include severe immune reactions, mutagenesis, and raised risk for cancer. Big efforts are being put into the development of ways of detection, however until now there are neither practicable methods of control nor any reported cases of manipulated humans. Still, a usage of gene doping that has already taken place cannot be ruled out and is highly likely. © Georg Thieme Verlag KG Stuttgart · New York.

  16. Stability analysis of direct current control in current source rectifier

    DEFF Research Database (Denmark)

    Lu, Dapeng; Wang, Xiongfei; Blaabjerg, Frede

    2017-01-01

    Current source rectifier with high switching frequency has a great potential for improving the power efficiency and power density in ac-dc power conversion. This paper analyzes the stability of direct current control based on the time delay effect. Small signal model including dynamic behaviors...

  17. Current challenges in tobacco control.

    Science.gov (United States)

    Slama, K

    2004-10-01

    Tobacco is the world's biggest preventable killer, but the circumstances of its history, the power and influence of its commerce and the nature of addiction make it a very difficult public health issue. Determinants of smoking are both individual and environmental. Genetics and environment influence to varying degrees all of the steps in a smoker's career. Persistence of use, degree of addiction to nicotine and difficulty in stopping are influenced by inherited traits and nicotine susceptibility, whereas the social environment and the individual's cognitions are the key factors in starting smoking and successfully stopping smoking. The tools available to tobacco control include influencing the social and cultural norms concerning tobacco; legislative and regulatory measures to protect the population and to limit tobacco industry marketing tactics, now encapsulated in the Framework Convention on Tobacco Control; and programmes to enhance the chance of not starting and successfully stopping. Strategies for tobacco control must work at both societal and individual levels, and directions are being taken that include genetic, pharmacological, behavioural, socio-cultural and international approaches.

  18. Variable current speed controller for eddy current motors

    Science.gov (United States)

    Gerth, H.L.; Bailey, J.M.; Casstevens, J.M.; Dixon, J.H.; Griffith, B.O.; Igou, R.E.

    1982-03-12

    A speed control system for eddy current motors is provided in which the current to the motor from a constant frequency power source is varied by comparing the actual motor speed signal with a setpoint speed signal to control the motor speed according to the selected setpoint speed. A three-phase variable voltage autotransformer is provided for controlling the voltage from a three-phase power supply. A corresponding plurality of current control resistors is provided in series with each phase of the autotransformer output connected to inputs of a three-phase motor. Each resistor is connected in parallel with a set of normally closed contacts of plurality of relays which are operated by control logic. A logic circuit compares the selected speed with the actual motor speed obtained from a digital tachometer monitoring the motor spindle speed and operated the relays to add or substract resistance equally in each phase of the motor input to vary the motor current to control the motor at the selected speed.

  19. Eddy Effects in the General Circulation, Spanning Mean Currents, Mesoscale Eddies, and Topographic Generation, Including Submesoscale Nests

    Science.gov (United States)

    2014-09-30

    alongshore winds favoring upwelling circulation. As for the other EBUS (e.g., Humboldt, Benguela, and Canary Currents ), equatorward winds drive...Eddy Effects in the General Circulation, Spanning Mean Currents , Mesoscale Eddies, and Topographic Generation, Including Submesoscale Nests...environments OBJECTIVES The central scientific questions are how the eddies control the persistent currents by their eddy-induced momentum and buoyancy fluxes

  20. Technical means overview of the oversize cargoes customs control

    Directory of Open Access Journals (Sweden)

    Dukhnitskiy P.S.

    2016-11-01

    Full Text Available this article focuses on the technical means used by the customs authorities when they control oversize cargoes. Customs inspection efficiency improvement as one of the main forms of customs control during the implementation of sampling is possible by the use of technical means of customs control.

  1. Technical means overview of the oversize cargoes customs control

    OpenAIRE

    Dukhnitskiy P.S.

    2016-01-01

    this article focuses on the technical means used by the customs authorities when they control oversize cargoes. Customs inspection efficiency improvement as one of the main forms of customs control during the implementation of sampling is possible by the use of technical means of customs control.

  2. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    Energy Technology Data Exchange (ETDEWEB)

    Alamgir, A.K.M. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)]. E-mail: alam643@hotmail.com; Gu, C. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China); Han, Z. [Applied Superconductivity Research Center, Department of Physics, Tsinghua University, Beijing 100084 (China)

    2005-11-15

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to {approx}11% by 50 {mu}m thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article.

  3. Experiment of enhancing critical current in Bi-2223/Ag tape by means of ferromagnetic shielding

    International Nuclear Information System (INIS)

    Alamgir, A.K.M.; Gu, C.; Han, Z.

    2005-01-01

    Critical current in multifilamentary Ag-sheath Bi-2223 tape is enhanced to some extent by means of thin and narrow coating of pure nickel. The concept of enhancing critical current is based on the magnetic shielding effect resulting in redirection of self-field flux lines. The Ni coating was introduced at the edge regime of the tape in order to redirect the perpendicular component of self-field lines which is severe at the edges. Critical current in a typical Ag-sheath Bi-2223 tape was enhanced up to ∼11% by 50 μm thick and 0.4 mm long Ni coating without any change of self-field loss. This fact reveals that additional ferromagnetic loss could be compensated by the shielding effect and increased critical current of the tape. The degree of enhancement in critical current as well as ferromagnetic impact on ac losses depend on the length and thickness of ferromagnetic coating introduced. Therefore, it is very important to control the geometry of ferromagnetic coating in order to balance the critical current and ac loss for optimum superconductor performance. Introduction of ferromagnetic coating and its effect on electromagnetic properties in multifilamentary Bi-2223/Ag tape will be reported in this article

  4. Are Current Accounts of Asian Economies Mean-reverting?: Nonlinear Unit Root Test Approach

    Directory of Open Access Journals (Sweden)

    Bonghan Kim

    2005-12-01

    Full Text Available This paper tests the mean reverting property of current account in the financial crisis-affected 5 counties of southeast Asia using nonlinear unit root tests of Park and shintani(2004. Our approach is based on the idea that a conventional unit root test has lower power in detecting the nonlinear mean reverting behavior if the current account follows a nonlinear mean reversion process. We obtained following empirical results. First, for the pre-crisis period (1981Q1-1996Q4, the current accounts of Indonesia, Malaysia and Philippines are mean-reverting but those of Korea and Thailand are not mean-reverting. Second, for the full sample period (1981Q1-2003Q4, the ADF test fails to reject the unit root of the current account in all countries except Philippines. However, unit root is rejected in favor of nonlinear mean reversion except Thailand. This nonlinear unit root test result implies that crisis-affected Asian countries except Thailand have sustainable paths of current accounts. Third, when the current accounts of East Asian countries are nonlinear mean-reverting, the mean reverting process can be well described by the ESTAR model, instead of the DTAR or DLSTAR model. The nonlinear unit root test results imply smooth nonlinear mean-reversion behaviors of East Asian current accounts. Finally, the shape of estimated impulse response functions becomes steeper as the size of shock increases, which is the very characteristic of the nonlinear process.

  5. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1980-01-01

    A specification is given for an energizing and regulating circuit for a gas filled neutron generator tube consisting of a target, an ion source and a replenisher, the circuit consisting of a power supply to provide a negative high voltage to the target and a target current corresponding to the neutron output of the tube, a constant current source, and control means connected to the power supply and to the constant current source, the control means being responsive to the target current to provide a portion of the constant current to the replenisher substantially to regulate the neutron output of the tube. (author)

  6. Tidal residual current and its role in the mean flow on the Changjiang Bank

    Science.gov (United States)

    Xuan, Jiliang; Yang, Zhaoqing; Huang, Daji; Wang, Taiping; Zhou, Feng

    2016-02-01

    The tidal residual current may play an important role in the mean flow in the Changjiang Bank region, in addition to other residual currents, such as the Taiwan Warm Current, the Yellow Sea Coastal Current, and the Yellow Sea Warm Current. In this paper, a detailed structure of the tidal residual current, in particular the meso-scale eddies, in the Changjiang Bank region is observed from model simulations, and its role in the mean flow is quantified using the well-validated Finite Volume Coastal Ocean Model. The tidal residual current in the Changjiang Bank region consists of two components: an anticyclonic regional-scale tidal residual circulation around the edge of the Changjiang Bank and some cyclonic meso-scale tidal residual eddies across the Changjiang Bank. The meso-scale tidal residual eddies occur across the Changjiang Bank and contribute to the regional-scale tidal residual circulation offshore at the northwest boundary and on the northeast edge of the Changjiang Bank, southeastward along the 50 m isobath. Tidal rectification is the major mechanism causing the tidal residual current to flow along the isobaths. Both components of the tidal residual current have significant effects on the mean flow. A comparison between the tidal residual current and the mean flow indicates that the contribution of the tidal residual current to the mean flow is greater than 50%.

  7. Tidal residual current and its role in the mean flow on the Changjiang Bank

    Energy Technology Data Exchange (ETDEWEB)

    Xuan, Jiliang; Yang, Zhaoqing; Huang, Daji; Wang, Taiping; Zhou, Feng

    2016-02-01

    Tidal residual current may play an important role in the mean flow in the Changjiang Bank region, in addition to other residual currents, such as the Taiwan Warm Current, the Yellow Sea Coastal Current, and the Yellow Sea Warm Current. In this paper, a detailed structure of the tidal residual current, in particular the meso-scale eddies, in the Changjiang Bank region is observed from model simulations, and its role in the mean flow is quantified using the well-validated Finite Volume Coastal Ocean Model). The tidal residual current in the Changjiang Bank region consists of two components: an anticyclonic regional-scale tidal residual circulation around the edge of the Changjiang Bank and some cyclonic meso-scale tidal residual eddies across the Changjiang Bank. The meso-scale tidal residual eddies occur across the Changjiang Bank and contribute to the regional-scale tidal residual circulation offshore at the northwest boundary and at the northeast edge of the Changjiang Bank, southeastward along the 50 m isobath. Tidal rectification is the major mechanism causing the tidal residual current to flow along the isobaths. Both components of the tidal residual current have significant effects on the mean flow. A comparison between the tidal residual current and the mean flow indicates that the contribution of the tidal residual current to the mean flow is greater than 50%.

  8. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1978-01-01

    Means and method are described for energizing and regulating a neutron generator tube having a target, an ion source and a replenisher. It providing a negative high voltage to the target and monitoring the target current. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordence with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current

  9. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    1977-01-01

    A means and method for energizing and regulating a neutron generator tube is described. It has a target, an ion source and a replenisher. A negative high voltage is applied to the target and the target current monitored. A constant current from a constant current source is divided into a shunt current and a replenisher current in accordance with the target current. The replenisher current is applied to the replenisher in a neutron generator tube so as to control the neutron output in accordance with the target current. (C.F.)

  10. Evaluation of hospital disinfection as a means of controlling endemic ...

    African Journals Online (AJOL)

    Evaluation of hospital environment disinfection as a means of controlling endemic nosocomial pathogens in a University Teaching Hospital in Nigeria was evaluated. Disinfectant used in the Hospital was collected from the Infection Control unit and prepared in different concentrations. The isolated bacterial species from the ...

  11. Current control of light by nonreciprocal magnetoplasmonics

    Energy Technology Data Exchange (ETDEWEB)

    Gong, Yongkang, E-mail: yongkang.gong@southwales.ac.uk; Li, Kang; Carver, Sara; Martinez, Juan Jose; Huang, Jungang; Copner, Nigel [Wireless and Optoelectronics Research and Innovation Centre (WORIC), Faculty of Computing, Engineering and Science, University of South Wales, Cardiff CF37 1DL (United Kingdom); Thueux, Yoann; Avlonitis, Nick [Airbus Group Innovations, Quadrant House, Celtic Springs, Coedkernew, NP10 8FZ Newport (United Kingdom)

    2015-05-11

    The ability to actively control light has long been a major scientific and technological goal. We proposed a scheme that allows for active control of light by utilizing the nonreciprocal magnetoplasmonic effect. As a proof of concept, we applied current signal through an ultrathin metallic film in a magneto-plasmonic multilayer and found that dynamic photonic nonreciprocity appears in magnetic-optical material layer due to the magnetic field being induced from current signal and modulates surface plasmon polaritons trapped in the metal surface and the light reflected. The proposed concept provides a possible way for the active control of light and could find potential applications such as ultrafast optoelectronic signal processing for plasmonic nanocircuit technology and ultrafast/large-aperture free-space electro-optic modulation platform for wireless laser communication technology.

  12. The application of mean control chart in managing industrial processes

    Directory of Open Access Journals (Sweden)

    Papić-Blagojević Nataša

    2013-01-01

    Full Text Available Along with the advent of mass production comes the problem of monitoring and maintaining the quality of the product, which stressed the need for the application of selected statistical and mathematical methods in the control process. The main objective of applying the methods of statistical control is continuous quality improvement through permanent monitoring of the process in order to discover the causes of errors. Shewart charts are the most popular method of statistical process control, which performs separation of controlled and uncontrolled variations along with detection of increased variations. This paper presents the example of Shewart mean control chart with application in managing industrial process.

  13. Green operations of belt conveyors by means of speed control

    NARCIS (Netherlands)

    He, D.; Pang, Y.; Lodewijks, G.

    2017-01-01

    Belt conveyors can be partially loaded due to the variation of bulk material flow loaded onto the conveyor. Speed control attempts to reduce the belt conveyor energy consumption and to enable the green operations of belt conveyors. Current research of speed control rarely takes the conveyor dynamics

  14. The meaning of "control" for childbearing women in the US.

    Science.gov (United States)

    Namey, Emily E; Lyerly, Anne Drapkin

    2010-08-01

    Childbearing women, healthcare providers, and commentators on birth broadly identify control as an important issue during childbirth; however, control is rarely defined in literature on the topic. Here we seek to deconstruct the term control as used by childbearing women to better understand the issues and concepts underpinning it. Based on qualitative interviews with 101 parous women in the United States, we analyze meanings of control within the context of birth narratives. We find these meanings correspond to five distinct domains: self-determination, respect, personal security, attachment, and knowledge. We also find ambivalence about this term and concept, in that half our sample recognizes "you cannot control birth". Together, these findings call into question the usefulness of the term for measuring quality or improving maternity care and highlight other concepts which may be more fruitfully explored. (c) 2010 Elsevier Ltd. All rights reserved.

  15. Disturbance observer based current controller for vector controlled IM drives

    DEFF Research Database (Denmark)

    Teodorescu, Remus; Dal, Mehmet

    2008-01-01

    induction motor (IM) drives. The control design, based on synchronously rotating d-q frame model of the machine, has a simple structure that combines the proportional portion of a conventional PI control and output of the observer. The observer is predicted to estimate the disturbances caused by parameters...... coupling effects and increase robustness against parameters change without requiring any other compensation strategies. The experimental implementation results are provided to demonstrate validity and performance of the proposed control scheme.......In order to increase the accuracy of the current control loop, usually, well known parameter compensation and/or cross decoupling techniques are employed for advanced ac drives. In this paper, instead of using these techniques an observer-based current controller is proposed for vector controlled...

  16. Thoracic radiotherapy and breath control: current prospects

    International Nuclear Information System (INIS)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R.

    2002-01-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  17. Visually and force controlled opening and closing of doors by means of a mobile robot arm

    OpenAIRE

    Milighetti, G.; Hoffmann, E.; Fetzner, Angelika; Kuntze, Helge-Björn

    2012-01-01

    A multi-sensory discrete-continuous control concept has been developed to realize interactive basic skills for humanoid and mobile service robots. In the upper hierarchy level a discrete task control structure enables the flexible execution of primitive skill sequences. In the lower continuous level a suitable controller is chosen with control parameters adapted to the current primitive skill. The basic skill for the frequently occurring task of unlocking and opening a door by means of a mobi...

  18. Current control by ECCD for W7-X

    International Nuclear Information System (INIS)

    Turkin, Yu.; Maassberg, H.; Beidler, C.D.; Geiger, J.; Marushchenko, N.B.

    2005-01-01

    One of the optimization criteria for the stellarator W7-X is the minimization of the bootstrap current. The plasma current changes the magnetic configuration, especially near the plasma edge, where X-points and islands are located. It was shown that the plasma parameter distributions in the divertor region and the particle and energy depositions on the divertor plates depend strongly on the island geometry. An estimation of the tolerable plasma current obtained from the shift of the island structure close to the target plates shows that the plasma current should be controlled within a range of about 10 kA. The bootstrap current even for the standard configuration can easily exceed this value. The W7-X is not equipped with an Ohmic transformer, so the only means for compensating this current is electron cyclotron current drive (ECCD) and/or neutral beam current drive (NBCD). In this report we study the compensation of residual bootstrap current by using ECCD. To model the control of the toroidal current we use a predictive 1D transport code, which is under development. For evaluation of the bootstrap current and neoclassical transport coefficients we use results from an international collaboration on neoclassical transport in stellarators. Power deposition and current drive profiles due to electron cyclotron resonance heating are calculated by a new ray tracing code. The modeling showed that the loop voltage induced by ECCD leads to a redistribution of the current density with the diffusion time of about two seconds. The relaxation time of the total current is much longer than this time - for a typical ECRH-plasma the total toroidal current reaches steady state after several L/R-time that is about hundreds of seconds. In order to keep current in an acceptable range and to avoid long relaxation times we propose Feed-forward or Predictive control using ECCD as actuator, the steps are as follows: - calculate the bootstrap current distribution using measured plasma

  19. MEASURING RESULTS NUMERAL TREATMENT OF IMPULSIVE CURRENTS BY MEANS OF ROGOVSKY BELT APPLICATION

    Directory of Open Access Journals (Sweden)

    U. Batygin

    2009-01-01

    Full Text Available The technique of numerical processing of measurement results of pulse currents by means of Rogovsky belt application is offered in the given work. It is shown that at measurement of signals by digital oscillographs and further numerical transformation of target signals, the possibilities of Rogovsky belt without the application of additional devices that in turn allows to define parameters of pulse currents with any peak-time characteristics essentially expand.

  20. A TRMM/GPM retrieval of the total mean generator current for the global electric circuit

    Science.gov (United States)

    Peterson, Michael; Deierling, Wiebke; Liu, Chuntao; Mach, Douglas; Kalb, Christina

    2017-09-01

    A specialized satellite version of the passive microwave electric field retrieval algorithm (Peterson et al., 2015) is applied to observations from the Tropical Rainfall Measuring Mission (TRMM) and Global Precipitation Measurement (GPM) satellites to estimate the generator current for the Global Electric Circuit (GEC) and compute its temporal variability. By integrating retrieved Wilson currents from electrified clouds across the globe, we estimate a total mean current of between 1.4 kA (assuming the 7% fraction of electrified clouds producing downward currents measured by the ER-2 is representative) to 1.6 kA (assuming all electrified clouds contribute to the GEC). These current estimates come from all types of convective weather without preference, including Electrified Shower Clouds (ESCs). The diurnal distribution of the retrieved generator current is in excellent agreement with the Carnegie curve (RMS difference: 1.7%). The temporal variability of the total mean generator current ranges from 110% on semi-annual timescales (29% on an annual timescale) to 7.5% on decadal timescales with notable responses to the Madden-Julian Oscillation and El Nino Southern Oscillation. The geographical distribution of current includes significant contributions from oceanic regions in addition to the land-based tropical chimneys. The relative importance of the Americas and Asia chimneys compared to Africa is consistent with the best modern ground-based observations and further highlights the importance of ESCs for the GEC.

  1. Self-consistent mean field forces in turbulent plasmas: Current and momentum relaxation

    International Nuclear Information System (INIS)

    Hegna, C.C.

    1997-08-01

    The properties of turbulent plasmas are described using the two-fluid equations. Under some modest assumptions, global constraints for the turbulent mean field forces that act on the ion and electron fluids are derived. These constraints imply a functional form for the parallel mean field forces in the Ohm's law and the momentum balance equation. These forms suggest that the fluctuations attempt to relax the plasma to a state where both the current and the bulk plasma momentum are aligned along the mean magnetic field with proportionality constants that are global constants. Observations of flow profile evolution during discrete dynamo activity in reversed field pinch experiments are interpreted

  2. One-pion exchange current corrections for nuclear magnetic moments in relativistic mean field theory

    International Nuclear Information System (INIS)

    Li Jian; Yao, J.M.; Meng Jie; Arima, Akito

    2011-01-01

    The one-pion exchange current corrections to isoscalar and isovector magnetic moments of double-closed shell nuclei plus and minus one nucleon with A = 15, 17, 39 and 41 have been studied in the relativistic mean field (RMF) theory and compared with previous relativistic and non-relativistic results. It has been found that the one-pion exchange current gives a negligible contribution to the isoscalar magnetic moments but a significant correction to the isovector ones. However, the one-pion exchange current enhances the isovector magnetic moments further and does not improve the corresponding description for the concerned nuclei in the present work. (author)

  3. Localization of endocardial ectopic activity by means of noninvasive endocardial surface current density reconstruction

    Energy Technology Data Exchange (ETDEWEB)

    Lai Dakun; Liu Chenguang; Eggen, Michael D; He Bin [Department of Biomedical Engineering, University of Minnesota, MN (United States); Iaizzo, Paul A, E-mail: binhe@umn.edu [Department of Surgery, University of Minnesota, MN (United States)

    2011-07-07

    Localization of the source of cardiac ectopic activity has direct clinical benefits for determining the location of the corresponding ectopic focus. In this study, a recently developed current-density (CD)-based localization approach was experimentally evaluated in noninvasively localizing the origin of the cardiac ectopic activity from body-surface potential maps (BSPMs) in a well-controlled experimental setting. The cardiac ectopic activities were induced in four well-controlled intact pigs by single-site pacing at various sites within the left ventricle (LV). In each pacing study, the origin of the induced ectopic activity was localized by reconstructing the CD distribution on the endocardial surface of the LV from the measured BSPMs and compared with the estimated single moving dipole (SMD) solution and precise pacing site (PS). Over the 60 analyzed beats corresponding to ten pacing sites (six for each), the mean and standard deviation of the distance between the locations of maximum CD value and the corresponding PSs were 16.9 mm and 4.6 mm, respectively. In comparison, the averaged distance between the SMD locations and the corresponding PSs was slightly larger (18.4 {+-} 3.4 mm). The obtained CD distribution of activated sources extending from the stimulus site also showed high consistency with the endocardial potential maps estimated by a minimally invasive endocardial mapping system. The present experimental results suggest that the CD method is able to locate the approximate site of the origin of a cardiac ectopic activity, and that the distribution of the CD can portray the propagation of early activation of an ectopic beat.

  4. Nonlinear Deadbeat Current Control of a Switched Reluctance Motor

    OpenAIRE

    Rudolph, Benjamin

    2009-01-01

    High performance current control is critical to the success of the switched reluctance motor (SRM). Yet high motor phase nonlinearities in the SRM place extra burden on the current controller, rendering it the weakest link in SRM control. In contrast to linear motor control techniques that respond to current error, the deadbeat controller calculates the control voltage by the current command, phase current, rotor position and applied phase voltage. The deadbeat controller has demonstrated sup...

  5. Sliding Mode Control of Induction Motor Phase Currents

    DEFF Research Database (Denmark)

    Hansen, R.B.; Hattel, T.; Bork, J

    1995-01-01

    Sliding mode control of induction motor phase currents are investigated through development of two control concepts.......Sliding mode control of induction motor phase currents are investigated through development of two control concepts....

  6. NASA Iced Aerodynamics and Controls Current Research

    Science.gov (United States)

    Addy, Gene

    2009-01-01

    This slide presentation reviews the state of current research in the area of aerodynamics and aircraft control with ice conditions by the Aviation Safety Program, part of the Integrated Resilient Aircraft Controls Project (IRAC). Included in the presentation is a overview of the modeling efforts. The objective of the modeling is to develop experimental and computational methods to model and predict aircraft response during adverse flight conditions, including icing. The Aircraft icing modeling efforts includes the Ice-Contaminated Aerodynamics Modeling, which examines the effects of ice contamination on aircraft aerodynamics, and CFD modeling of ice-contaminated aircraft aerodynamics, and Advanced Ice Accretion Process Modeling which examines the physics of ice accretion, and works on computational modeling of ice accretions. The IRAC testbed, a Generic Transport Model (GTM) and its use in the investigation of the effects of icing on its aerodynamics is also reviewed. This has led to a more thorough understanding and models, both theoretical and empirical of icing physics and ice accretion for airframes, advanced 3D ice accretion prediction codes, CFD methods for iced aerodynamics and better understanding of aircraft iced aerodynamics and its effects on control surface effectiveness.

  7. Meaning

    Science.gov (United States)

    Harteveld, Casper

    The second world to be considered concerns Meaning. In contrast to Reality and Play, this world relates to the people, disciplines, and domains that are focused on creating a certain value. For example, if this value is about providing students knowledge about physics, it involves teachers, the learning sciences, and the domains education and physics. This level goes into the aspects and criteria that designers need to take into account from this perspective. The first aspect seems obvious when we talk of “games with a serious purpose.” They have a purpose and this needs to be elaborated on, for example in terms of what “learning objectives” it attempts to achieve. The subsequent aspect is not about what is being pursued but how. To attain a value, designers have to think about a strategy that they employ. In my case this concerned looking at the learning paradigms that have come into existence in the past century and see what they have to tell us about learning. This way, their principles can be translated into a game environment. This translation involves making the strategy concrete. Or, in other words, operationalizing the plan. This is the third aspect. In this level, I will further specifically explain how I derived requirements from each of the learning paradigms, like reflection and exploration, and how they can possibly be related to games. The fourth and final aspect is the context in which the game is going to be used. It matters who uses the game and when, where, and how the game is going to be used. When designers have looked at these aspects, they have developed a “value proposal” and the worth of it may be judged by criteria, like motivation, relevance, and transfer. But before I get to this, I first go into how we human beings are meaning creators and what role assumptions, knowledge, and ambiguity have in this. I will illustrate this with some silly jokes about doctors and Mickey Mouse, and with an illusion.

  8. Bioherbicides: Current knowledge on weed control mechanism.

    Science.gov (United States)

    Radhakrishnan, Ramalingam; Alqarawi, Abdulaziz A; Abd Allah, Elsayed Fathi

    2018-04-17

    Weed control is a challenging event during crop cultivation. Integrated management, including the application of bioherbicides, is an emerging method for weed control in sustainable agriculture. Plant extracts, allelochemicals and some microbes are utilized as bioherbicides to control weed populations. Bioherbicides based on plants and microbes inhibit the germination and growth of weeds; however,few studies conducted in weed physiology. This review ascribes the current knowledge of the physiological changes in weeds that occur during the exposure to bioherbicides. Plant extracts or metabolites are absorbed by weed seeds, which initiates damage to the cell membrane, DNA, mitosis, amylase activity and other biochemical processes and delays or inhibits seed germination. The growth of weeds is also retarded due to low rates of root-cell division, nutrient uptake, photosynthetic pigment synthesis, and plant growth hormone synthesis, while the productions of reactive oxygen species (ROS) and stress-mediated hormones increase, including irregular antioxidant activity. However, lytic enzymes and toxic substances secreted from microbes degrade the weed seed coat and utilize the endosperm for survival, which inhibits seed germination. The microbes grow through the intercellular spaces to reach the root core, and the deposition of toxins in the cells affects cell division and cellular functions. Some of the metabolites of deleterious microbes cause disease, necrosis and chlorosis,which inhibit the germination and growth of weed seeds by suppressing photosynthesis and gibberellin activities and enhancing ROS, abscisic acid and ethylene. This review explains the effects of bioherbicides (derived from plants and microbes) on weed-plant physiology to elucidate their modes of action. Copyright © 2018 Elsevier Inc. All rights reserved.

  9. DETERMINATION OF HYDRAULIC TURBINE EFFICIENCY BY MEANS OF THE CURRENT METER METHOD

    Directory of Open Access Journals (Sweden)

    PURECE C.

    2016-12-01

    Full Text Available The paper presents methodology used for determining the efficiency of a low head Kaplan hydraulic turbine with short converging intake. The measurement method used was the current meters method, the only measurement method recommended by the IEC 41standard for flow measurement in this case. The paper also presents the methodology used for measuring the flow by means of the current meters method and the various procedures for calculating the flow. In the last part the paper presents the flow measurements carried out on the Fughiu HPP hydraulic turbines for determining the actual operating efficiency.

  10. Social Bots: Human-Like by Means of Human Control?

    Science.gov (United States)

    Grimme, Christian; Preuss, Mike; Adam, Lena; Trautmann, Heike

    2017-12-01

    Social bots are currently regarded an influential but also somewhat mysterious factor in public discourse and opinion making. They are considered to be capable of massively distributing propaganda in social and online media, and their application is even suspected to be partly responsible for recent election results. Astonishingly, the term social bot is not well defined and different scientific disciplines use divergent definitions. This work starts with a balanced definition attempt, before providing an overview of how social bots actually work (taking the example of Twitter) and what their current technical limitations are. Despite recent research progress in Deep Learning and Big Data, there are many activities bots cannot handle well. We then discuss how bot capabilities can be extended and controlled by integrating humans into the process and reason that this is currently the most promising way to realize meaningful interactions with other humans. This finally leads to the conclusion that hybridization is a challenge for current detection mechanisms and has to be handled with more sophisticated approaches to identify political propaganda distributed with social bots.

  11. Universities with multicultural disrupted past: what meanings current students attribute to them?

    Directory of Open Access Journals (Sweden)

    Olena Dobosh

    2016-09-01

    Full Text Available The changing of pre-war borders of Central and Eastern Europe after WW II caused not only belonging of certain territories to definite countries but also the massive forced relocation of population from those territories. The total change of the population in the multicultural cities affected also institutions, such as universities by changing their staff, language, and national profile. Nowadays, when modern universities are facing post-modernity challenges it is extremely difficult to talk about role, mission, and meaning of this institution, especially in the context of disrupted historical tradition. Look at the problem from the different perspective, from inside will show the tendencies of meanings current students of the universities with long but disrupted historical past attribute to their Alma maters. Are they aware of the presence of representatives of different national groups that created university community before WW II? This article will present results of three studies conducted at three universities that changed their national profile after WWII: Vilnius University in Lithuania (formerly a Polish university, Lviv University in Ukraine (formerly a Polish university and Wrocław University in Poland (formerly a German university. Both at Vilnius University and Lviv Universiy 150 university students participated in the study. At Wrocław University 152 university students participated in the study. The present analysis will try to explore the variety of meanings current students of those three universities attribute to their place of study. It will try to show if current students are aware of the university’s complex history and, if they include/exclude historical meanings connected with representatives of the different national group? Also, it will look at the possible differences between meaning attribution and perception of the university past among representatives of these three universities. Lviv, Wrocław, and Vilnius

  12. Current control necessary for toroidal plasma equilibrium

    International Nuclear Information System (INIS)

    Nagao, S.

    1987-01-01

    It is shown that a significant amount of dipole current is necessary for the plasma equilibrium of toroidal configurations in general. Through the vector product with the poloidal field, this dipole current force has to balance with the hoop force of plasma pressure itself of the annular shape. The measurement of such a current of dipole type may be interesting for the confirmation of the plasma equilibrium in the toroidal system. Moreover it is certained that there is a new mode of a tokamak operation with such a dipole current component and with smaller vertical field than that based on the classical tokamak theory. (author) [pt

  13. Using a 1200 kHz workhorse ADCP with mode 12 to measure near bottom mean currents

    Science.gov (United States)

    Martini, M.; ,

    2003-01-01

    Using high frequency Acoustic Doppler Current (ADCP) profiling technology, it is possible to make high-resolution measurements of mean current profiles within a few meters of the seabed. In coastal applications, mean current speeds may be 10 cm/s or less, and oscillatory wave currents may exceed 100 cm/s during storm events. To resolve mean flows of 10 cm/s or less under these conditions, accuracies of 1 cm/s or better are desirable.

  14. Control of the current density profile with lower hybrid current drive on PBX-M

    International Nuclear Information System (INIS)

    Bell, R.E.; Bernabei, S.; Chu, T.K.; Gettelfinger, G.; Greenough, N.; Hatcher, R.; Ignat, D.; Jardin, S.; Kaita, R.; Kaye, S.; Kozub, T.; Kugel, H.; LeBlanc, B.; Okabayashi, M.; Paul, S.; Sauthoff, N.; Sesnic, S.; Sun, Y.; Takahashi, H.; Tighe, W.; Valeo, E.; von Goeler, S.; Jones, S.; Kesner, J.; Luckhardt, S.; Paoletti, F.; Levinton, F.; Timini, F.

    1993-07-01

    Lower hybrid current drive (LHCD) is being explored as a means to control the current density profile on PBX-M with the goal of raising the central safety factor q(O) to values of 1.5-2 to facilitate access to a full-volume second stable regime. Initial experiments have been conducted with up to 400 kW of 4.6 GHz LH power in circular and indented plasmas with modest parameters. A tangential-viewing two-dimensional hard x-ray imaging diagnostic has been used to observe the bremsstrahlung emission from the suprathermal electrons generated during LHCD. Hollow hard x-ray images have indicated off-axis localization of the driven current. A serious obstacle to the control of the current density profile with LHCD is the concomitant generation of MHD activity, which can seriously degrade the confinement of suprathermal electrons. By combining neutral beam injection with LHCD, an MHD-free condition has been obtained where q(O) is raised above 1

  15. Pest control of ligniperdous insects by means of ionizing radiation

    International Nuclear Information System (INIS)

    Baer, M.; Koehler, W.

    1983-01-01

    Wooden objects of art and monuments are endangered by wood-destroying insects. The treatment of these objects with ionizing radiation is one way to control these pests. For this purpose the portable HWK-3 high-dose irradiation device was developed. In July 1979, a radiation experiment was made under field conditions in Potsdam-Sanssouci in order to gain experience in the operation and effectiveness of the new device. During the following 18 months the results of this experiment were evaluated by means of the SM 231 vibration measuring instrument. It became evident that a total dose of over 3 kGy would kill all of the death-watch beetles (Anobium punctatum de Geer) and doses down to 0.55 kGy would largely diminish the population, with future damages caused by death-watch beetles being highly unlikely. Delayed damages in the larvae caused by low total doses still add to the effectiveness of the pest control. (author)

  16. Linear quadratic Gaussian controller design for plasma current, position and shape control system in ITER

    International Nuclear Information System (INIS)

    Belyakov, V.; Kavin, A.; Rumyantsev, E.; Kharitonov, V.; Misenov, B.; Ovsyannikov, A.; Ovsyannikov, D.; Veremei, E.; Zhabko, A.; Mitrishkin, Y.

    1999-01-01

    This paper is focused on the linear quadratic Gaussian (LQG) controller synthesis methodology for the ITER plasma current, position and shape control system as well as power derivative management system. It has been shown that some poloidal field (PF) coils have less influence on reference plasma-wall gaps control during plasma disturbances and hence they have been used to reduce total control power derivative by means of the additional non-linear feedback. The design has been done on the basis of linear models. Simulation was provided for non-linear model and results are presented and discussed. (orig.)

  17. Quantitatively Probing the Means of Controlling Nanoparticle Assembly on Surfaces

    Energy Technology Data Exchange (ETDEWEB)

    Patete, J.m.; Wong, S.; Peng, X.; Serafin, J.M.

    2011-05-17

    As a means of developing a simple, cost-effective, and reliable method for probing nanoparticle behavior, we have used atomic force microscopy to gain a quantitative 3D visual representation of the deposition patterns of citrate-capped Au nanoparticles on a substrate as a function of (a) sample preparation, (b) the choice of substrate, (c) the dispersion solvent, and (d) the number of loading steps. Specifically, we have found that all four parameters can be independently controlled and manipulated in order to alter the resulting pattern and quantity of as-deposited nanoparticles. From these data, the sample preparation technique appears to influence deposition patterns most broadly, and the dispersion solvent is the most convenient parameter to use in tuning the quantity of nanoparticles deposited onto the surface under spin-coating conditions. Indeed, we have quantitatively measured the effect of surface coverage for both mica and silicon substrates under preparation techniques associated with (i) evaporation under ambient air, (ii) heat treatment, and (iii) spin-coating preparation conditions. In addition, we have observed a decrease in nanoparticle adhesion to a substrate when the ethylene glycol content of the colloidal dispersion solvent is increased, which had the effect of decreasing interparticle-substrate interactions. Finally, we have shown that substrates prepared by these diverse techniques have potential applicability in surface-enhanced Raman spectroscopy.

  18. Quantitatively Probing the Means of Controlling Nanoparticle Assembly on Surfaces

    International Nuclear Information System (INIS)

    Patete, J.M.; Wong, S.; Peng, X.; Serafin, J.M.

    2011-01-01

    As a means of developing a simple, cost-effective, and reliable method for probing nanoparticle behavior, we have used atomic force microscopy to gain a quantitative 3D visual representation of the deposition patterns of citrate-capped Au nanoparticles on a substrate as a function of (a) sample preparation, (b) the choice of substrate, (c) the dispersion solvent, and (d) the number of loading steps. Specifically, we have found that all four parameters can be independently controlled and manipulated in order to alter the resulting pattern and quantity of as-deposited nanoparticles. From these data, the sample preparation technique appears to influence deposition patterns most broadly, and the dispersion solvent is the most convenient parameter to use in tuning the quantity of nanoparticles deposited onto the surface under spin-coating conditions. Indeed, we have quantitatively measured the effect of surface coverage for both mica and silicon substrates under preparation techniques associated with (i) evaporation under ambient air, (ii) heat treatment, and (iii) spin-coating preparation conditions. In addition, we have observed a decrease in nanoparticle adhesion to a substrate when the ethylene glycol content of the colloidal dispersion solvent is increased, which had the effect of decreasing interparticle-substrate interactions. Finally, we have shown that substrates prepared by these diverse techniques have potential applicability in surface-enhanced Raman spectroscopy.

  19. Speed controller for an alternating - current motor

    International Nuclear Information System (INIS)

    Bolie, V.W.

    1984-01-01

    A controller for a multi-phase ac motor that is subject to a large inertial load, e.g. an induction motor driving a heavy spinning rotor of a neutron chopper that must be rotated in phase-locked synchronism with a reference pulse train that is representative of an ac power supply signal Esub(L) having a meandering line frequency, includes a sensor which provides a feedback pulse train representative of the actual speed of the motor which is compared (by counting clock pulses between feedback pulses) with a reference clock signal in a computing unit to provide a motor control signal Esub(c). The motor control signal is a weighted linear sum of a speed error signal, a phase error signal, and a drift error signal, the magnitudes of which are recalculated and updated with each revolution of the motor shaft. The speed error signal is constant for large speed errors but highly sensitive to small speed errors. The stator windings of the motor are driven by variable-frequency power amplifiers which are controlled by the motor control signal Esub(c) via PROMs which store digital representations of sine and cosine waveforms in quadrature. (author)

  20. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2001-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... without further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as experimentally on the actual induction motor, both in open-loop current control and when an outer...... speed control loop is closed around the current loop...

  1. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2003-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as on the actual induction motor, both in open-loop current control and when an outer speed control loop...... is closed around the current loop....

  2. BIOLOGICAL CONTROL OF WEEDS BY MEANS OF PLANT PATHOGENS

    OpenAIRE

    Marija Ravlić; Renata Baličević

    2014-01-01

    Biological control is the use of live beneficial organisms and products of their metabolism in the pests control. Plant pathogens can be used for weed control in three different ways: as classical, conservation and augmentative (inoculative and inundated) biological control. Inundated biological control involves the use of bioherbicides (mycoherbicides) or artificial breeding of pathogens and application in specific stages of crops and weeds. Biological control of weeds can be used where chem...

  3. Malaria vector control: current and future strategies

    NARCIS (Netherlands)

    Takken, W.; Knols, B.G.J.

    2009-01-01

    The recently announced call for malaria eradication represents a new page in the history of this disease. This has been triggered by remarkable reductions in malaria resulting from combined application of effective drugs and vector control. However, this strategy is threatened by development of

  4. Electrolytic tritium enrichment: Current control using current-stabilised Kepco Type JQE modular supplies

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1976-07-12

    This note describes the principles, design and operation of a current-stabilised power source for tritium electrolytic enrichment cells. A Kepoo Tpe JE, modular supply is current-stabilised by controlled current feedback. The accompanying control unit incorporates a temperature sensor or the cooling unit of the electrolysis cells, a line monitor to register current shut-off due to temporary power failure, a time-of-day clock, a current control potentiometer and a digital voltmeter providing current reading to an accuracy of 0.01A.

  5. Electrolytic tritium enrichment: Current control using current-stabilised Kepco Type JQE modular supplies

    International Nuclear Information System (INIS)

    1976-01-01

    This note describes the principles, design and operation of a current-stabilised power source for tritium electrolytic enrichment cells. A Kepoo Tpe JE, modular supply is current-stabilised by controlled current feedback. The accompanying control unit incorporates a temperature sensor or the cooling unit of the electrolysis cells, a line monitor to register current shut-off due to temporary power failure, a time-of-day clock, a current control potentiometer and a digital voltmeter providing current reading to an accuracy of 0.01A

  6. Iaverage current mode (ACM) control for switching power converters

    OpenAIRE

    2014-01-01

    Providing a fast current sensor direct feedback path to a modulator for controlling switching of a switched power converter in addition to an integrating feedback path which monitors average current for control of a modulator provides fast dynamic response consistent with system stability and average current mode control. Feedback of output voltage for voltage regulation can be combined with current information in the integrating feedback path to limit bandwidth of the voltage feedback signal.

  7. Designing single phase Current-Programmed-Controlled rectifiers by harmonic currents

    DEFF Research Database (Denmark)

    Andersen, Gert Karmisholt; Blaabjerg, Frede

    2002-01-01

    The grid current harmonics of a Current-Programmed-Controlled (CPC) pfc rectifier strongly depends on the choice of switching frequency and switching inductance. This paper describes a new simple and vert fast method to calculate the grid current of a CPC controlled pfc converter. The method...

  8. Automatic control system for measuring currents produced by ionization chambers

    International Nuclear Information System (INIS)

    Brancaccio, Franco

    2002-01-01

    Ionization Chambers in current mode operation are usually used in Nuclear Metrology. Activity measurements are quickly performed by Ionization Chambers, with very good precision. For this purpose measurements of very low ionization currents, carried out by high quality instrumentation, are required. Usually, electrometers perform the current integration method under command of signals from an automation system, in order to reduce the measurement uncertainties. Among the measurement systems at the Laboratorio de Metrologia Nuclear (LMN) of IPEN, there are two ionization chamber systems. In the present work, an automation system developed for current integration measurements is described. This automation system is composed by software (graphic interface and control) and an electronic module connected to a microcomputer, by means of a commercial data acquisition card. Several test measurements were performed in order to determine the intrinsic uncertainty, linearity and stability of the system. Using calibrated radioactive solutions, the IG12/A20 chamber calibration factors for 18 F and 153 Sm were obtained, making possible to determine activities of these radionuclides. (author)

  9. BIOLOGICAL CONTROL OF WEEDS BY MEANS OF PLANT PATHOGENS

    Directory of Open Access Journals (Sweden)

    Marija Ravlić

    2014-06-01

    Full Text Available Biological control is the use of live beneficial organisms and products of their metabolism in the pests control. Plant pathogens can be used for weed control in three different ways: as classical, conservation and augmentative (inoculative and inundated biological control. Inundated biological control involves the use of bioherbicides (mycoherbicides or artificial breeding of pathogens and application in specific stages of crops and weeds. Biological control of weeds can be used where chemical herbicides are not allowed, if resistant weed species are present or in the integrated pest management against weeds with reduced herbicides doses and other non-chemical measures, but it has certain limitations and disadvantages.

  10. Tuberculosis control in the Americas: current approaches.

    Science.gov (United States)

    Pio, A; Western, K

    1976-01-01

    Tuberculosi remains a serious public health problem in the Americas, and it has not declined as rapidly or as much as experts projected it would in the 1940's. Scientific advances in control of the disease over the last three decades have produced effective chemotherapeutic agents, established the immunizing capacity of BCG vaccine, and demonstrated the superior value of bacteriologic diagnosis in symptomatic individuals over mass community x-ray surveys, which are both inefficient and costly. They have also shown that most cases can be treated on an ambulatory basis, obviating the need for the lengthy hospital stays which have heretofore weighed so heavily on budgets. By standardization of control methods, both for diagnosis and for chemotherapy, these tasks can be taken on by polyvalent staff in the general health services, whose wide coverage places them in a position to reach a much larger segment of the population than that attended by the traditional vertical system. To a greater or lesser degree, all the countries in the Americas are beginning to orient their strategies in this direction, and some of them already have considerable progress to report.

  11. Current control system for superconducting coils of LHD

    International Nuclear Information System (INIS)

    Chikaraishi, H.; Yamada, S.; Inoue, T.

    1996-01-01

    This paper introduce a coil current control system of the LHD. The main part of this system consists of two VME based real time computers and a risc based work station which are connected by optical fiber link. In this computer system, a coil current controller for steady state operation of LHD which based on a state variable control theory is installed. Also advanced current control scheme, which are now developing for dynamic current control in phase II operation of LHD, are introduced. (author)

  12. Adaptive slope compensation for high bandwidth digital current mode controller

    DEFF Research Database (Denmark)

    Taeed, Fazel; Nymand, Morten

    2015-01-01

    An adaptive slope compensation method for digital current mode control of dc-dc converters is proposed in this paper. The compensation slope is used for stabilizing the inner current loop in peak current mode control. In this method, the compensation slope is adapted with the variations...... in converter duty cycle. The adaptive slope compensation provides optimum controller operation in term of bandwidth over wide range of operating points. In this paper operation principle of the controller is discussed. The proposed controller is implemented in an FPGA to control a 100 W buck converter...

  13. Team Electronic Gameplay Combining Different Means of Control

    Science.gov (United States)

    Pope, Alan T. (Inventor); Palsson, Olafur S. (Inventor)

    2014-01-01

    Disclosed are methods and apparatuses provided for modifying the effect of an operator controlled input device on an interactive device to encourage the self-regulation of at least one physiological activity by a person different than the operator. The interactive device comprises a display area which depicts images and apparatus for receiving at least one input from the operator controlled input device to thus permit the operator to control and interact with at least some of the depicted images. One effect modification comprises measurement of the physiological activity of a person different from the operator, while modifying the ability of the operator to control and interact with at least some of the depicted images by modifying the input from the operator controlled input device in response to changes in the measured physiological signal.

  14. Constrained deterministic leader-follower mean field control

    NARCIS (Netherlands)

    Möller, L.; Gentile, B.; Parise, F.; Grammatico, S.; Lygeros, J.

    2016-01-01

    We consider a mean field game among a large population of noncooperative agents divided into two categories: leaders and followers. Each agent is subject to heterogeneous convex constraints and minimizes a quadratic cost function; the cost of each leader is affected by the leaders' aggregate

  15. Current developments in bovine mastitis treatment and control.

    Science.gov (United States)

    Wager, L A; Linquist, W E; Hayes, G L; Britten, A M; Whitehead, R G; Webster, D E; Barnes, F D

    1978-01-01

    Mastitis in its complexity has managed to forestall all efforts of eradication in spite of years of research, antibiotics and practical control measures. This minisymposium will touch on seven topics current to treatment and control of this economically important disease.

  16. From linear to nonlinear control means: a practical progression.

    Science.gov (United States)

    Gao, Zhiqiang

    2002-04-01

    With the rapid advance of digital control hardware, it is time to take the simple but effective proportional-integral-derivative (PID) control technology to the next level of performance and robustness. For this purpose, a nonlinear PID and active disturbance rejection framework are introduced in this paper. It complements the existing theory in that (1) it actively and systematically explores the use of nonlinear control mechanisms for better performance, even for linear plants; (2) it represents a control strategy that is rather independent of mathematical models of the plants, thus achieving inherent robustness and reducing design complexity. Stability analysis, as well as software/hardware test results, are presented. It is evident that the proposed framework lends itself well in seeking innovative solutions to practical problems while maintaining the simplicity and the intuitiveness of the existing technology.

  17. Reducing Multisensor Satellite Monthly Mean Aerosol Optical Depth Uncertainty: 1. Objective Assessment of Current AERONET Locations

    Science.gov (United States)

    Li, Jing; Li, Xichen; Carlson, Barbara E.; Kahn, Ralph A.; Lacis, Andrew A.; Dubovik, Oleg; Nakajima, Teruyuki

    2016-01-01

    Various space-based sensors have been designed and corresponding algorithms developed to retrieve aerosol optical depth (AOD), the very basic aerosol optical property, yet considerable disagreement still exists across these different satellite data sets. Surface-based observations aim to provide ground truth for validating satellite data; hence, their deployment locations should preferably contain as much spatial information as possible, i.e., high spatial representativeness. Using a novel Ensemble Kalman Filter (EnKF)- based approach, we objectively evaluate the spatial representativeness of current Aerosol Robotic Network (AERONET) sites. Multisensor monthly mean AOD data sets from Moderate Resolution Imaging Spectroradiometer, Multiangle Imaging Spectroradiometer, Sea-viewing Wide Field-of-view Sensor, Ozone Monitoring Instrument, and Polarization and Anisotropy of Reflectances for Atmospheric Sciences coupled with Observations from a Lidar are combined into a 605-member ensemble, and AERONET data are considered as the observations to be assimilated into this ensemble using the EnKF. The assessment is made by comparing the analysis error variance (that has been constrained by ground-based measurements), with the background error variance (based on satellite data alone). Results show that the total uncertainty is reduced by approximately 27% on average and could reach above 50% over certain places. The uncertainty reduction pattern also has distinct seasonal patterns, corresponding to the spatial distribution of seasonally varying aerosol types, such as dust in the spring for Northern Hemisphere and biomass burning in the fall for Southern Hemisphere. Dust and biomass burning sites have the highest spatial representativeness, rural and oceanic sites can also represent moderate spatial information, whereas the representativeness of urban sites is relatively localized. A spatial score ranging from 1 to 3 is assigned to each AERONET site based on the uncertainty

  18. Current control loop of 3-phase grid-connected inverter

    International Nuclear Information System (INIS)

    Jabbar, A F; Mansor, M

    2013-01-01

    This paper presents a comparative study of current control loop in 3-phase inverter which is used to control the active and reactive output power. Generally, current control loop, power control loop and phase lock-loop are the conventional parameters that can be found in an inverter system controlled by the conventional linear control type, for instance proportional (P), integral (I) and derivative (D). If the grid remains stable throughout the day, PID control can be use. However variation of magnitude, frequency, voltage dips, transient, and other related power quality issues occur in a 3-phase grid often affects the control loop. This paper aims to provide an overall review on the available current control techniques used in grid connected system.

  19. Zener diode controls switching of large direct currents

    Science.gov (United States)

    1965-01-01

    High-current zener diode is connected in series with the positive input terminal of a dc supply to block the flow of direct current until a high-frequency control signal is applied across the zener diode. This circuit controls the switching of large dc signals.

  20. Current Control of Grid Converters Connected with Series AC Capacitor

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Loh, Poh Chiang

    2015-01-01

    The series ac capacitor has recently been used with the transformerless grid-connected converters in the distribution power grids. The capacitive characteristic of the resulting series LC filter restricts the use of conventional synchronous integral or stationary resonant current controllers. Thus...... this paper proposes a fourth-order resonant controller in the stationary frame, which guarantees a zero steady-state current tracking error for the grid converters with series LC filter. This method is then implemented in a three-phase experimental system for verification, where the current harmonics below...... the LC filter resonance frequency are effectively eliminated. Experimental results confirm the validity of the proposed current control scheme....

  1. Optimization of a radiodiagnostic service by means of quality control

    International Nuclear Information System (INIS)

    Carrizales, L.; Gamez, L.; Reggio, F.; Gamboa, M.; Quintero, A.; Almeida, J.

    2001-01-01

    Most of the radio diagnosis institutions (public and private) in Venezuela have a lack quality control applied to radiological equipment, as well as capable staff to implement it. It is intended to implant training programs and corrective policies to optimize their services [es

  2. Reading comprehension metacognitive strategies as a means for controlling behavior

    Directory of Open Access Journals (Sweden)

    Dinorah Aladina Caballero López

    2014-07-01

    Full Text Available Textual comprehension implies the use of various metacognitive strategies by the students when they have to face a text to be competent readers. That is why the objective of this article is to illustrate the application of metacognitive strategies in order to achieve an efficient textual comprehension, taking into account the self – regulation the student exerts over his own learning process. It is applied as the main method historical-logical studies based on a professional-researching systematic practice; at the same time observation is largely used. The main result is the introduction of metacognitive strategies in reading comprehension, which subsequently favor the self-control of personal behavior. The article is the result of a research project sponsored by the department of Special Education. Key words: reading comprehension, metacognitive strategies, behavior self-control.

  3. Surveillance and control of containment by means of radioactive measurements

    International Nuclear Information System (INIS)

    Roche, H.; Seveon, J.J.; Rousseau, L.; Delalande, J.

    1983-12-01

    In this paper, the radioactive measurements participating in the surveillance and control of the reactor containment as well as the possible procedures or operating rules related to, especially the ultimate procedures which could be implemented in case of a beyond of design accident, are presented. However, an overall view of the plant radiation monitoring system installed on the French plants is first given. If necessary, difference between 900 MW and 1300 MW units are emphasized

  4. Control of ring lasers by means of coupled cavities

    DEFF Research Database (Denmark)

    Buchhave, Preben; Abitan, Haim; Tidemand-Lichtenberg, Peter

    2000-01-01

    Variable phase coupling to an external ring is used to control a unidirectional ring laser. The observed behavior of the coupled rings is explained theoretically. We have found experimentally that by quickly changing the phase of the feedback from the external ring it is possible to Q......-switch the ring laser. Also, at certain values of the phase of the feedback in the external ring, instabilities in the total system occur and oscillations arise in the ring laser....

  5. Optimized load sharing control by means of thermal reliability management

    DEFF Research Database (Denmark)

    Nesgaard, Carsten; Andersen, Michael Andreas E.

    2004-01-01

    time and system cost. However, due to non-ideal parts each converter unit deviates from the ideal case, which makes a power system comprised of parallel-connected converters a rather poor performing system. To account for the non-ideal parts some form of load sharing is needed, whereby it is ensured......With new applications for high-current low-output voltage power systems emerging nearly every day the need for new and cost-efficient power system designs is a matter of course. As output voltage levels continue to decrease an approach that seems more and more attractive is the implementation...... that each converter in the configuration delivers its share of the total output power. In other words parallel-operation of multiple converters is employed when specifications require a highly reliable system, designable within a very short time frame and at low costs. However, to make full use...

  6. Means, methods and performances of the AREVA's HTR compact controls

    International Nuclear Information System (INIS)

    Banchet, J.; Guillermier, P.; Tisseur, D.; Vitali, M. P.

    2008-01-01

    In the AREVA's HTR development program, the reactor plant is composed of a prismatic core containing graphite cylindrical fuel elements, called compacts, where TRISO particles are dispersed. Starting from its past compacting process, the latter being revamped through the use of state of the art equipments, CERCA, 100% AREVA NP's subsidiary, was able to recover the quality of past compacts production. The recovered compacting process is composed of the following manufacturing steps: graphite matrix granulation, mix between the obtained granulates and particles, compacting and calcining at low pressure and temperature. To adapt this past process to new manufacturing equipments, non destructive examination tests were carried out to assess the compact quality, the latter being assessed via in house developed equipments and methods at each step of the design of experiments. As for the manufacturing process, past quality control methods were revamped to measure compact dimensional features (diameter, perpendicularity and cone effect), visual aspect, SiC layer failure fraction (via anodic disintegration and burn leach test) and homogeneity via 2D radiography coupled to ceramography. Although meeting quality requirements, 2D radiography method could not provide a quantified specification for compact homogeneity characterization. This limitation yielded the replacement of this past technique by a method based on X-Ray tomography. Development was conducted on this new technique to enable the definition of a criterion to quantify compact homogeneity, as well as to provide information about the distances in between particles. This study also included a comparison between simulated and real compacts to evaluate the accuracy of the technique as well as the influence of particle packing fraction on compact homogeneity. The developed quality control methods and equipments guided the choices of manufacturing parameters adjustments at the development stage and are now applied for

  7. Review of experiments on current drive in tokamaks by means of RF waves

    International Nuclear Information System (INIS)

    Hooke, W.

    1984-01-01

    Experimental results on lower hybrid current drive in tokamak plasmas are reviewed. Pulse lengths of 3.5 seconds and currents above 400 kA have been generated at plasma densities such that the wave frequency is greater than about twice the lower hybrid frequency. Current drive ceases above a critical density, nsub(c). However, nsub(c) increases with wave frequency. So that for f = 4.6 GHz current drive has been seen at n-barsub(e) approx.= 10 14 cm -3 and a density limit has yet to be established. Evidence for a collisional scaling law for current-drive efficiency is summarized. Detailed measurements of bremsstrahlung x-rays show a distribution which is qualitatively similar to that predicted by quasilinear theory. Microwave emission at frequencies less than the plasma frequency may shed light on the current-drive mechanism. Applications of current drive including plasma and current start-up and transformer recharging are discussed. (author)

  8. Simplified current minimization control of vector controlled Interior ...

    Indian Academy of Sciences (India)

    Thakur Sumeet Singh

    2018-04-12

    Apr 12, 2018 ... looked into loss-minimization control of PM motors by use of polynomial .... the chosen motor (''Appendix'') falls outside of its range. Figure 1. ..... command, mmf balance along q-axis should be maintained: (Lq being ...

  9. Discrete-Time LPV Current Control of an Induction Motor

    DEFF Research Database (Denmark)

    Bendtsen, Jan Dimon; Trangbæk, Klaus

    2003-01-01

    In this paper we apply a new method for gain-scheduled output feedback control of nonlinear systems to current control of an induction motor. The method relies on recently developed controller synthesis results for linear parameter-varying (LPV) systems, where the controller synthesis is formulated...... as a set of linear matrix inequalities with full-block multipliers. A standard nonlinear model of the motor is constructed and written on LPV form. We then show that, although originally developed in continuous time, the controller synthesis results can be applied to a discrete-time model as well without...... further complications. The synthesis method is applied to the model, yielding an LPV discrete-time controller. Finally, the efficiency of the control scheme is validated via simulations as well as on the actual induction motor, both in open-loop current control and when an outer speed control loop...

  10. Going Open: Does it Mean Giving Away Control?

    Directory of Open Access Journals (Sweden)

    Michael Weiss

    2013-01-01

    Full Text Available Open source software has evolved from being an effort driven by a collective of volunteers to become an integral part of commercial software. Constant demands for new features besides maintaining product quality made companies seek open source as an answer for these demands. These growing demands brought with them control of quality, architecture, contribution management, and community management. This article explores the governance strategies adopted by open source software projects to manage the quality of complements (such as plug-ins that extend a platform's functionality developed by community members outside the core team. The outcomes of the research contribute to our understanding of the strategies followed by different open source platform owners (the open source project initiators to manage external innovation in the case of platform extensions in two areas: i governance models and ii regulatory tools.

  11. Mean Value SI Engine Model for Control Studies

    DEFF Research Database (Denmark)

    Hendricks, Elbert; Sorenson, Spencer C

    1990-01-01

    This paper presents a mathematically simple nonlinear three state (three differential equation) dynamic model of an SI engine which has the same steady state accuracy as a typical dynamometer measurement of the engine over its entire speed/load operating range (± 2.0%). The model's accuracy...... for large, fast transients is of the same order in the same operating region. Because the model is mathematically compact, it has few adjustable parameters and is thus simple to fit to a given engine either on the basis of measurements or given the steady state results of a larger cycle simulation package....... The model can easily be run on a Personal Computer (PC) using a ordinary differential equation (ODE) integrating routine or package. This makes the model is useful for control system design and evaluation....

  12. Restrictive Diet Control as a Means of Child Abuse.

    Science.gov (United States)

    Kudek, Matthew R; Luyet, Francois; Herringa, Ryan J; Knox, Barbara L

    2018-03-01

    We have recently encountered a series of cases where an obese caretaker is juxtaposed to a severely starved, malnourished dependent. The cases described all share a common characteristic: that the primary perpetrator was an obese caretaker who tried to exert absolute control over their victim's daily life in a way that included either a severe restriction or complete denial of food. Because the pathophysiology of both child abuse and obesity are incredibly complex and multifactorial, these cases are presented to encourage further discussion and more rigorous investigation into the validity of a hypothesis that has been derived from this set of cases: that the obesity of a child's caretaker may be an additional risk factor for child maltreatment by starvation.

  13. Eddy current quality control of soldered current-carrying busbar splices of superconducting magnets

    CERN Document Server

    Kogan, L; Savary, F; Principe, R; Datskov, V; Rozenfel'd, E; Khudjakov, B

    2015-01-01

    The eddy current technique associated with a U-shaped transducer is studied for the quality control of soldered joints between superconducting busbars ('splices'). Two other quality control techniques, based on X-rays and direct measurement of the electrical resistance, are also studied for comparison. A comparative analysis of the advantages and disadvantages of these three methods in relation to the quality control of soldered superconducting busbar cables enclosed in copper shells is used for benchmarking. The results of inspections with the U-shaped eddy current transducer carried out on several sample joints presenting different types of soldering defects show the potential of this type of nondestructive (ND) quality control technique.

  14. Pricing as a means of controlling alcohol consumption.

    Science.gov (United States)

    Sharma, Anurag; Sinha, Kompal; Vandenberg, Brian

    2017-09-01

    Reducing the affordability of alcohol, by increasing its price, is the most effective strategy for controlling alcohol consumption and reducing harm. We review meta-analyses and systematic reviews of alcohol tax/price effects from the past decade, and recent evaluations of tax/price policies in the UK, Canada and Australia. While the magnitudes of price effects vary by sub-group and alcoholic beverage type, it has been consistently shown that price increases lead to reductions in alcohol consumption. There remains, however, a lack of consensus on the most appropriate taxation and pricing policy in many countries because of concerns about effects by different consumption level and income level and disagreement on policy design between parts of the alcoholic beverage industries. Recent developments in the research highlight the importance of obtaining accurate alcohol price data, reducing bias in estimating price responsiveness, and examining the impact on the heaviest drinkers. There is a need for further research focusing on the substitution effects of taxation and pricing policies, estimation of the true tax pass-through rates, and empirical analysis of the supply-side response (from alcohol producers and retailers) to various alcohol pricing strategies. © The Author 2017. Published by Oxford University Press. All rights reserved. For permissions, please e-mail: journals.permissions@oup.com

  15. Current control of superconducting coils for fusion experimental facility

    International Nuclear Information System (INIS)

    Ise, T.; Etou, D.; Chikaraishi, H.; Takami, S.; Inoue, T.

    2003-01-01

    The LHD (Large Helical Device) has twelve superconducting coils and six dc power supplies, and following specifications are required for its control system; each coil current must be controlled independently, the steady state control error is less than 0.01% of the reference value, the current settling time for 0.1% of control error is less than 1 second, and the control system must be robust against turbulence caused by appearance and disappearance of the plasma, parameter errors and external electro-magnetic noises. In this paper, the design and test results of the coil current control system for the LHD are described. The good response and robustness are in the relation of trade off each other. H-infinity controller is one of schemes to guarantee robustness for stability. However, the independent responses of six coils were impossible by the H-infinity controller only. To resolve this problem, we applied a feed-forward control with the H-infinity control. Moreover, the advanced design method of H-infinity controller using μ-synthesis was applied to guarantee the control performance in the whole operating condition. As a result, good control results were obtained by experiments. (author)

  16. Method of controlling illumination device based on current-voltage model

    DEFF Research Database (Denmark)

    2013-01-01

    The present invention relates to an illumination device comprising a number of LEDs, means for receiving an input signal, means for generating an activation signal for at least one of the LEDs based on the input signal. The illumination device comprises further means for obtaining the voltage...... and the colorimetric properties of said light emitted by LED. The present invention relates also to a method of controlling and a meted of calibrating such illumination device....... across and current through the LED and the means for generating the activation signal is adapted to generate the activating signal based on the voltage, the current and a current- voltage model related to LED. The current-voltage model defines a relationship between the current, the voltage...

  17. Means for controlling operation of power sources associated with an axial tomographic system

    International Nuclear Information System (INIS)

    1976-01-01

    An axial tomographic system is described having scanner means normally in an off-condition where all associated power sources are electrically isolated from the units driven thereby. It also includes means for activating the scanner means to establish an on-condition, control means including means to measure one or more system parameters when the scanner means is in an on-condition and to determine if the measured parameters are within predetermined limits, and means for maintaining the on-condition only if the control means is properly operational and all measured system parameters are within the predetermined limits

  18. The production of high poloidal tokamak equilibria in Versator II by means of RF current drive

    International Nuclear Information System (INIS)

    Luckhardt, S.C.; Chen, K.-I.; Kesner, J.; Kirkwood, R.; Lane, B.; Porkolab, M.; Squire, J.

    1989-01-01

    Experiments on the Versator II device have been carried out in a regime of low plasma current with the aim of reaching high poloidal beta, β p . Lower-Hybrid RF current drive is used to produce an energetic electron population which carries the plasma current and pressure. In this mode of operation, plasmas with εβ p approaching unity appear attainable. Data from equilibrium magnetic analysis, hard x-ray, and density profiles display an outward magnetic axis shift in agreement with equilibrium theory, and further indicate that q(O) is in the range of 4-6. PEST code modeling of these experiments suggests that some of these plasmas may be near or beyond the transition to the second stability region for ballooning modes. (author)

  19. Estimating the North Atlantic mean dynamic topography and geostrophic currents with GOCE

    DEFF Research Database (Denmark)

    Bingham, Rory J.; Knudsen, Per; Andersen, Ole Baltazar

    2011-01-01

    Three GOCE gravity models were released in July 2010 based on two months of observations. Subsequently, two second generation models, based on 8 months of observations, were released in March 2011. This paper compares these five models in terms of the mean North Atlantic circulation that can be d...

  20. A current controlled variable delay superconducting transmission line

    International Nuclear Information System (INIS)

    Anlage, S.M.; Snortland, H.J.; Beasley, M.R.

    1989-01-01

    The authors present a device concept for a current-controlled variable delay for superconducting transmission line. The device makes use of the change in kinetic inductance of a superconducting transmission line under the application of a DC bias current. The relevant materials parameters and several promising superconducting materials have been identified

  1. Current control by a homopolar machine with moving brushes

    International Nuclear Information System (INIS)

    Vogel, H.

    1978-01-01

    The equation for TNS Doublet's E-coil circuit with moving brush homopolar machine is integrated in the flux of the homopolar for a monotonically increasing current function extending beyond the current reversal into the burn period. The results show that the moving brush feature is not useful for controlling the burn

  2. Discrete Current Control Strategy of Permanent Magnet Synchronous Motors

    Directory of Open Access Journals (Sweden)

    Yan Dong

    2013-01-01

    Full Text Available A control strategy of permanent magnet synchronous motors (PMSMs, which is different from the traditional vector control (VC and direct torque control (DTC, is proposed. Firstly, the circular rotating magnetic field is analyzed on the simplified model and discredited into stepping magnetic field. The stepping magnetomotive force will drive the rotor to run as the stepping motor. Secondly, the stator current orientation is used to build the control model instead of rotor flux orientation. Then, the discrete current control strategy is set and adopted in positioning control. Three methods of the strategy are simulated in computer and tested on the experiment platform of PMSM. The control precision is also verified through the experiment.

  3. High Precision Current Control for the LHC Main Power Converters

    CERN Document Server

    Thiesen, H; Hudson, G; King, Q; Montabonnet, V; Nisbet, D; Page, S

    2010-01-01

    Since restarting at the end of 2009, the LHC has reached a new energy record in March 2010 with the two 3.5 TeV beams. To achieve the performance required for the good functioning of the accelerator, the currents in the main circuits (Main Bends and Main Quadrupoles) must be controlled with a higher precision than ever previously requested for a particle accelerator at CERN: a few parts per million (ppm) of nominal current. This paper describes the different challenges that were overcome to achieve the required precision for the current control of the main circuits. Precision tests performed during the hardware commissioning of the LHC illustrate this paper.

  4. Characterization and optimized control by means of multi-parameter controllers

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Carsten; Hoeg, S.; Thoegersen, A. (Dan-Ejendomme, Hellerup (Denmark)) (and others)

    2009-07-01

    Poorly functioning HVAC systems (Heating, Ventilation and Air Conditioning), but also separate heating, ventilation and air conditioning systems are costing the Danish society billions of kroner every year: partly because of increased energy consumption and high operational and maintenance costs, but mainly due to reduced productivity and absence due to illness because of a poor indoor climate. Typically, the operation of buildings and installations takes place today with traditional build-ing automation, which is characterised by 1) being based on static considerations 2) the individual sensor being coupled with one actuator/valve, i.e. the sensor's signal is only used in one place in the system 3) subsystems often being controlled independently of each other 4) the dynamics in building constructions and systems which is very important to the system and comfort regulation is not being considered. This, coupled with the widespread tendency to use large glass areas in the facades without sufficient sun shading, means that it is difficult to optimise comfort and energy consumption. Therefore, the last 10-20 years have seen a steady increase in the complaints of the indoor climate in Danish buildings and, at the same time, new buildings often turn out to be considerably higher energy consuming than expected. The purpose of the present project is to investigate the type of multi parameter sensors which may be generated for buildings and further to carry out a preliminary evaluation on how such multi parameter controllers may be utilized for optimal control of buildings. The aim of the project isn't to develop multi parameter controllers - this requires much more effort than possible in the present project. The aim is to show the potential of using multi parameter sensors when controlling buildings. For this purpose a larger office building has been chosen - an office building with at high energy demand and complaints regarding the indoor climate. In order to

  5. Phase separation and soluble pollutant removal by means of alternationg current electrocoagulation

    International Nuclear Information System (INIS)

    Farrell, C.W.; Gardner-Clayson, T.W.

    1992-01-01

    Electro-Pure Systems (EPS) has undertaken a two-year laboratory program to investigate the technical and economic viability of alternation current electrocoagulation technology (ACE Technology) for Superfund site remediation. Alternating current electrocoagulation was originally developed as a treatment technology in the early 1980s to break stable aqueous suspensions of clays and coal fines in the mining industry. The technology offers a replacement for primary chemical coagulant addition to simplify effluent treatment, realize cost savings, and facilitate recovery of fine grained products that would otherwise have been lost. The traditional approach for treatment of such effluents entails addition of organic polymers or inorganic salts to promote flocculation of fine particulates and colloidi-sized oil droplets in aqueous suspensions. These flocculated materials are than separated by sedimentation or filtration. Unfortunately, chemical coagulant addition generates voluminous, gelatinous sludges which are difficult to dewater and slow to filter. As an alternative to chemical conditioning, alternation current electrocoagulation introduces into an aqueous medium highly, charged polymetric aluminum hydroxide species which will neutralize the electrostatic charges on suspended solids and oil droplets to facilitate their agglomeration (or coagulation). These species will also coprecipitate many soluble ions. ACE Technology prompts coagulation without adding any soluble species and produces a sludge with a lower contained water content and which will filter more rapidly through separation of the hazardous components from an aqueous waste the volume of potentially toxic pollutants requiring special handling and disposal can be minimized. Waste reduction goals may be accomplished by integrating this technology into a variety of operations which generate contaminated water

  6. Evaluation of Current Controllers for Distributed Power Generation Systems

    DEFF Research Database (Denmark)

    Timbus, Adrian; Liserre, Marco; Teodorescu, Remus

    2009-01-01

    This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional-integral, proportio......This paper discusses the evaluation of different current controllers employed for grid-connected distributed power generation systems having variable input power, such as wind turbines and photovoltaic systems. The focus is mainly set on linear controllers such as proportional......-integral, proportional-resonant, and deadbeat (DB) controllers. Additionally, an improved DB controller robust against grid impedance variation is also presented. Since the paper discusses the implementation of these controllers for grid-connected applications, their evaluation is made in three operating conditions....... First, in steady-state conditions, the contribution of controllers to the total harmonic distortion of the grid current is pursued. Further on, the behavior of controllers in the case of transient conditions like input power variations and grid voltage faults is also examined. Experimental results...

  7. Corrosion Assessment of Steel Bars Used in Reinforced Concrete Structures by Means of Eddy Current Testing

    Science.gov (United States)

    de Alcantara, Naasson P.; da Silva, Felipe M.; Guimarães, Mateus T.; Pereira, Matheus D.

    2015-01-01

    This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT) to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works. PMID:26712754

  8. Corrosion Assessment of Steel Bars Used in Reinforced Concrete Structures by Means of Eddy Current Testing

    Directory of Open Access Journals (Sweden)

    Naasson P. de Alcantara

    2015-12-01

    Full Text Available This paper presents a theoretical and experimental study on the use of Eddy Current Testing (ECT to evaluate corrosion processes in steel bars used in reinforced concrete structures. The paper presents the mathematical basis of the ECT sensor built by the authors; followed by a finite element analysis. The results obtained in the simulations are compared with those obtained in experimental tests performed by the authors. Effective resistances and inductances; voltage drops and phase angles of wound coil are calculated using both; simulated and experimental data; and demonstrate a strong correlation. The production of samples of corroded steel bars; by using an impressed current technique is also presented. The authors performed experimental tests in the laboratory using handmade sensors; and the corroded samples. In the tests four gauges; with five levels of loss-of-mass references for each one were used. The results are analyzed in the light of the loss-of-mass and show a strong linear behavior for the analyzed parameters. The conclusions emphasize the feasibility of the proposed technique and highlight opportunities for future works.

  9. Adaptive Hysteresis Band Current Control for Transformerless Single-Phase PV Inverters

    DEFF Research Database (Denmark)

    Vázquez, Gerardo; Rodriguez, Pedro; Ordoñez, Rafael

    2009-01-01

    Current control based on hysteresis algorithms are widely used in different applications, such as motion control, active filtering or active/reactive power delivery control in distributed generation systems. The hysteresis current control provides to the system a fast and robust dynamic response......, and requires a simple implementation in standard digital signal platforms. On the other hand, the main drawback of classical hysteresis current control lies in the fact that the switching frequency is variable, as the hysteresis band is fixed. In this paper a variable band hysteresis control algorithm...... different single-phase PV inverter topologies, by means of simulations performed with PSIM. In addition, the behavior of the thermal losses when using each control structure in such converters has been studied as well....

  10. Increase in operation safety of high-current pulsed accelerators by means of nonlinear resistances

    International Nuclear Information System (INIS)

    Demidov, B.A.; Ivkin, M.V.; Petrov, V.A.; Fanchenko, S.D.

    1975-01-01

    A circuit for connecting a shaping line through a nonlinear resistor in a high-current pulsed accelerator is proposed and investigated experimentally. For experimental purposes standard resistors are used as nonlinear resistors, they are made in the form of cylinders 100 mm in dia and 60 mm long. The results obtained show that if two resistors are connected in series, the reduction in an initial potential is less than 5% at the logarithmic damping coefficient equal to 1.3. It is also shown that such a method allows elimination of the reverse pumpover of energy to the storage device for untimely actuation of a spark gap that results in the prolongation of the time of potential applying thereby it permits a substantial increase in the reliability of a high-voltage insulation [ru

  11. New Approaches to Circulating Current Controllers for Modular Multilevel Converters

    Directory of Open Access Journals (Sweden)

    Miguel Moranchel

    2017-01-01

    Full Text Available In the next years, modular multilevel converters (MMCs are going to be a next generation multilevel converters for medium to high voltage conversion applications, such as medium voltage motor drives, medium voltage flexible AC transmission systems (FACTS and high voltage direct current transmission. They provide advantages such as high modularity, availability, low generation of harmonics, etc. However, the circulating current distorts the leg currents and increases the rated current of power devices, which further increases system cost. This paper focuses on analysis and suppression of these currents in a MMC using two algorithms for tracking of harmonics. For this work resonant controllers and repetitive controllers have been selected. Both controllers are analyzed and simulations results are presented. Moreover, the controllers have been tested and validated for a three phase MMC operating as an inverter using a real processing platform based on Zynq by Xilinx and designed to control large multilevel converters and in a real MMC prototype. These results are provided to demonstrate the feasibility of the proposed method.

  12. On the concept of virtual current as a means to enhance verification of electromagnetic flowmeters

    International Nuclear Information System (INIS)

    Baker, Roger C

    2011-01-01

    Electromagnetic flowmeters are becoming increasingly widely used in the water industry and other industries which handle electrically conducting liquids. When installed they are often difficult to remove for calibration without disturbing the liquid flow. Interest has therefore increased in the possibility of in situ calibration. The result has been the development of verification which attempts to approach calibration. However, while it checks on magnetic field and amplification circuits, it does not check adequately on the internals of the flowmeter pipe. This paper considers the use of the virtual voltage, a key element of the weight function theory of the flowmeter, to identify changes which have occurred in the flow tube and its liner. These could include a deformed insulating liner to the flow tube, or a deposit in the tube resulting from solids in the flow. The equation for virtual voltage is solved using a finite difference approach and the results are checked using a tank to simulate the flow tube, and tests on a flow rig. The concept is shown to be promising as a means of approaching verification of calibration

  13. Electron mean free path dependence of the critical currents and the pair-breaking limit in superconducting films

    International Nuclear Information System (INIS)

    Fedorov, N.; Rinderer, L.

    1977-01-01

    We have studied the current-induced breakdown of superconductivity in wide (100--980 μm) and thin (0.25--0.98 μm) films of tin. It is shown that the current at which the resistance of the sample begins to rise rapidly in the process of the destruction of superconductivity by a current can be fairly well associated with the theoretical value of the pair-breaking current in the Ginzburg-Landau phenomenological approach (I/sub c//sup G L/). This effect is observed over a rather wide temperature region (up to ΔTapprox.0.7 K), depending on the electron mean free path in the films. The values of the critical currents outside the above-mentioned region correlate qualitatively with those determined by inhomogeneities of the films as proposed by Larkin and Ovchinnikov

  14. Active current control in wind power plants during grid faults

    DEFF Research Database (Denmark)

    Martinez, Jorge; Kjær, Phillip C.; Rodriguez, Pedro

    2010-01-01

    Modern wind power plants are required and designed to ride through faults in electrical networks, subject to fault clearing. Wind turbine fault current contribution is required from most countries with a high amount of wind power penetration. In order to comply with such grid code requirements......, wind turbines usually have solutions that enable the turbines to control the generation of reactive power during faults. This paper addresses the importance of using an optimal injection of active current during faults in order to fulfil these grid codes. This is of relevant importance for severe...... faults, causing low voltages at the point of common coupling. As a consequence, a new wind turbine current controller for operation during faults is proposed. It is shown that to achieve the maximum transfer of reactive current at the point of common coupling, a strategy for optimal setting of the active...

  15. Search for right-handed currents by means of muon spin rotation

    International Nuclear Information System (INIS)

    Stoker, D.P.

    1985-01-01

    A muon spin rotation (μSR) technique has been used to place limits on right-handed weak currents in μ + decay. A beam of almost 100% polarized surface muons obtained from the TRIUMF M13 beamline was stopped in essentially non-depolarizing >99.99% pure metal foils. The μ + spins were precessed by 70-G or 110-G transverse fields. Decay e + emitted within 225 mrad of the beam direction and with momenta above 46 MeV/c were momentum-analyzed to 0.2%. Comparison of the μSR signal amplitude with that expected for (V-A) decay yields an endpoint asymmetry XiP/sub μ/δ/rho > 0.9951 with 90% confidence. In the context of manifest left-right symmetric models with massless neutrinos the results imply the 90% confidence limits M(W 2 ) > 381 GeV/c 2 and -0.057 2 is a predominantly right-handed gauge boson and zeta is the left-right mixing angle. Limits on M(W 2 ) for M(nu/sub μR/) does not equal 0 are also presented. The endpoint asymmetry is used to deduce limits on the nu/sub μL/ mass and helicity in π + decay, non-(V-A) couplings in helicity projection form, and the mass scale of composite leptons

  16. Search for right-handed currents by means of muon spin rotation

    International Nuclear Information System (INIS)

    Stoker, D.P.

    1985-09-01

    A muon spin rotation (μSR) technique has been used to place limits on right-handed weak currents in μ + decay. A beam of almost 100% polarized 'surface' muons obtained from the TRIUMF M13 beamline was stopped in essentially non-depolarizing >99.99% pure metal foils. The μ + spins were precessed by 70-G or 110-G transverse fields. Decay e + emitted within 225 mrad of the beam direction and with momenta above 46 MeV/c were momentum-analyzed to 0.2%. Comparison of the μSR signal amplitude with that expected for (V-A) decay yields an endpoint asymmetry xiPμdelta/rho>0.9951 with 90% confidence. In the context of manifest left-right symmetric models with massless neutrinos the results imply the 90% confidence limits M(W 2 )>381 GeV/c 2 and -0.057 2 is a predominantly right-handed gauge boson and zeta is the left-right mixing angle. Limits on M(W 2 ) for M(nu/sub μR) is not equal to 0 are also presented. The endpoint asymmetry is used to deduce limits on the nu/sub nu/sub μL/ mass and helicity in π + decay, non-(V-A) couplings in helicity projection form, and the mass scale of composite leptons

  17. Magnetohydrodynamic effects of current profile control in reversed field pinches

    International Nuclear Information System (INIS)

    Sovinec, C.R.; Prager, S.C.

    1999-01-01

    Linear and non-linear MHD computations are used to investigate reversed field pinch configurations with magnetic fluctuations reduced through current profile control. Simulations with reduced ohmic drive and moderate auxiliary current drive, represented generically with an electron force term, applied locally in radius near the plasma edge show magnetic fluctuation energies that are orders of magnitude smaller than those in simulations without profile control. The core of the improved configurations has reduced magnetic shear and closed flux surfaces in some cases, and reversal is sustained through the auxiliary current drive. Modes resonant near the edge may become unstable with auxiliary drive, but their saturation levels can be controlled. The space of auxiliary drive parameters is explored, and the ill effects of deviating far from optimal conditions is demonstrated in non-linear simulations. (author)

  18. Micromagnetic analysis of geometrically controlled current-driven magnetization switching

    Directory of Open Access Journals (Sweden)

    O. Alejos

    2017-05-01

    Full Text Available The magnetization dynamics induced by current pulses in a pair of two “S-shaped” ferromagnetic elements, each one consisting on two oppositely tilted tapered spikes at the ends of a straight section, is theoretically studied by means of micromagnetic simulations. Our results indicate that the magnetization reversal is triggered by thermal activation, which assists the current-induced domain nucleation and the propagation of domain walls. The detailed analysis of the magnetization dynamics reveals that the magnetization switching is only achieved when a single domain wall is nucleated in the correct corner of the element. In agreement with recent experimental studies, the switching is purely dictated by the shape, being independent of the current polarity. The statistical study points out that successful switching is only achieved within a narrow range of the current pulse amplitudes.

  19. Errors of Mean Dynamic Topography and Geostrophic Current Estimates in China's Marginal Seas from GOCE and Satellite Altimetry

    DEFF Research Database (Denmark)

    Jin, Shuanggen; Feng, Guiping; Andersen, Ole Baltazar

    2014-01-01

    and geostrophic current estimates from satellite gravimetry and altimetry are investigated and evaluated in China's marginal seas. The cumulative error in MDT from GOCE is reduced from 22.75 to 9.89 cm when compared to the Gravity Recovery and Climate Experiment (GRACE) gravity field model ITG-Grace2010 results......The Gravity Field and Steady-State Ocean Circulation Explorer (GOCE) and satellite altimetry can provide very detailed and accurate estimates of the mean dynamic topography (MDT) and geostrophic currents in China's marginal seas, such as, the newest high-resolution GOCE gravity field model GO......-CONS-GCF-2-TIM-R4 and the new Centre National d'Etudes Spatiales mean sea surface model MSS_CNES_CLS_11 from satellite altimetry. However, errors and uncertainties of MDT and geostrophic current estimates from satellite observations are not generally quantified. In this paper, errors and uncertainties of MDT...

  20. Generalized space vector control for current source inverters and rectifiers

    Directory of Open Access Journals (Sweden)

    Roseline J. Anitha

    2016-06-01

    Full Text Available Current source inverters (CSI is one of the widely used converter topology in medium voltage drive applications due to its simplicity, motor friendly waveforms and reliable short circuit protection. The current source inverters are usually fed by controlled current source rectifiers (CSR with a large inductor to provide a constant supply current. A generalized control applicable for both CSI and CSR and their extension namely current source multilevel inverters (CSMLI are dealt in this paper. As space vector pulse width modulation (SVPWM features the advantages of flexible control, faster dynamic response, better DC utilization and easy digital implementation it is considered for this work. This paper generalizes SVPWM that could be applied for CSI, CSR and CSMLI. The intense computation involved in framing a generalized space vector control are discussed in detail. The algorithm includes determination of band, region, subregions and vectors. The algorithm is validated by simulation using MATLAB /SIMULINK for CSR 5, 7, 13 level CSMLI and for CSR fed CSI.

  1. On Ion Cyclotron Current Drive for sawtooth control

    International Nuclear Information System (INIS)

    Eriksson, L.-G.; Johnson, T.; Hellsten, T.; Mayoral, M.-L.; McDonald, D.; Santala, M.; Vries, P. de; Coda, S.; Sauter, O.; Mueck, A.; Buttery, R.J.; Mantsinen, M.J.; Noterdaeme, J.-M.; Westerhof, E.

    2006-01-01

    Experiments using Ion Cyclotron Current Drive (ICCD) to control sawteeth are presented. In particular, discharges demonstrating shortening of fast ion induced long sawteeth reported in [L.-G. Eriksson et al., Physical Review Letters 92, 235004 (2004)] by ICCD have been analysed in detail. Numerical simulations of the ICCD driven currents are shown to be consistent with the experimental observations. They support the hypothesis that an increase of the magnetic shear, due to the driven current, at the surface where the safety factor is unity was the critical factor for the shortening of the sawteeth. In view of the potential utility of ICCD, the mechanisms for the current drive have been further investigated experimentally. This includes the influence of the averaged energy of the resonating ions carrying the current and the spectrum of the launched waves. The results of these experiments are discussed in the light of theoretical considerations. (author)

  2. Controlling the structure of forced convective flow by means of rotating magnetic-field inductors

    International Nuclear Information System (INIS)

    Sorkin, M.Z.; Mozgirs, O.Kh.

    1993-01-01

    The forced convective flow generated by a rotating magnetic-field inductor is used in a melt as a means of controlling the transfer of mass and heat in the case of directed crystallization. An obvious advantage in using a rotating field is the generation of azimuthal twisting of the fluid, this providing for an evening out of the crystallization conditions in the azimuthal direction under nonsymmetrical boundary conditions in an actual technological process. From the standpoint of affecting the crystallization processes it would be preferable to use an inductor which would allow alteration of the intensity and of the direction of the meridional flow. Mixing in the form of velocity pulsations generated by the inductor within the melt would be if interest from the standpoint of affecting the crystallization processes, in particular to intensify the crystallization purification. The authors propose the use of a double magnetohydrodynmic rotator which consists of two rotating magnetic-field inductors, separated in altitude, with separate power supplies. The supply of power to the inductors with various current loads allows the generation of a controllable nonuniformity in field distribution and in the azimuthal velocity through the altitude and thus allows control of both the intensity and configuration of the meridional flows. The dual rotator makes it possible to purposefully control the structure of the meridional flows and the pulsation component of velocity and can be recommended for use in processes of directed crystallization as well as in crystallization purification. 4 refs., 3 figs

  3. Online social networking and US poison control centers: Facebook as a means of information distribution.

    Science.gov (United States)

    Vo, Kathy; Smollin, Craig

    2015-06-01

    Online social networking services such as Facebook provide a novel medium for the dissemination of public health information by poison control centers in the United States. We performed a cross-sectional study of poison control center Facebook pages to describe and assess the use of this medium. Facebook pages associated with poison control centers were identified during a continuous two-week period from December 24, 2012 to January 7, 2013. Data were extracted from each page, including affiliated poison control center; page duration, measured in years since registration; number of subscribers; number of postings by general toxicological category; and measures of user-generated activity including "likes", "shares", and comments per posting. Among the 56 US poison control centers, 39 Facebook pages were identified, of which 29 were currently active. The total number of active pages has increased by 140% from 2009 to 2013 (average of 25% per year). The total number of all subscribers to active pages was 11,211, ranging from 40 to 2,456 (mean 387, SD 523), equal to 0.006% of all Facebook users in the United States. The number of subscribers per page was associated with page duration, number of postings, and type of postings. The types of toxicological postings were public education (45%), self-promotion (28%), childhood safety (12%), drugs of abuse (8%), environmental poisonings (6%), and general overdoses (1%). Slightly over half of all poison control centers in the United States are supplementing their outreach and education efforts through Facebook. In general, the more active the poison control center on Facebook, the more page followers and follower engagement gained.

  4. Current control for magnetized plasma in direct-current plasma-immersion ion implantation

    International Nuclear Information System (INIS)

    Tang Deli; Chu, Paul K.

    2003-01-01

    A method to control the ion current in direct-current plasma-immersion ion implantation (PIII) is reported for low-pressure magnetized inductively coupled plasma. The ion current can be conveniently adjusted by applying bias voltage to the conducting grid that separates plasma formation and implantation (ion acceleration) zones without the need to alter the rf input power, gas flux, or other operating conditions. The ion current that diminishes with an increase in grid bias in magnetized plasmas can be varied from 48 to 1 mA by increasing the grid voltage from 0 to 70 V at -50 kV sample bias and 0.5 mTorr hydrogen pressure. High implantation voltage and monoenergetic immersion implantation can now be achieved by controlling the ion current without varying the macroscopic plasma parameters. The experimental results and interpretation of the effects are presented in this letter. This technique is very attractive for PIII of planar samples that require on-the-fly adjustment of the implantation current at high implantation voltage but low substrate temperature. In some applications such as hydrogen PIII-ion cut, it may obviate the need for complicated sample cooling devices that must work at high voltage

  5. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    International Nuclear Information System (INIS)

    Leng Min-Rui; Zhou Guo-Hua; Zhang Kai-Tun; Li Zhen-Hua

    2015-01-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. (paper)

  6. Power electronic converters PWM strategies and current control techniques

    CERN Document Server

    Monmasson, Eric

    2013-01-01

    A voltage converter changes the voltage of an electrical power source and is usually combined with other components to create a power supply. This title is devoted to the control of static converters, which deals with pulse-width modulation (PWM) techniques, and also discusses methods for current control. Various application cases are treated. The book is ideal for professionals in power engineering, power electronics, and electric drives industries, as well as practicing engineers, university professors, postdoctoral fellows, and graduate students.

  7. Control of bootstrap current in the pedestal region of tokamaks

    Energy Technology Data Exchange (ETDEWEB)

    Shaing, K. C. [Institute for Space and Plasma Sciences, National Cheng Kung University, Tainan City 70101, Taiwan (China); Department of Engineering Physics, University of Wisconsin, Madison, Wisconsin 53796 (United States); Lai, A. L. [Institute for Space and Plasma Sciences, National Cheng Kung University, Tainan City 70101, Taiwan (China)

    2013-12-15

    The high confinement mode (H-mode) plasmas in the pedestal region of tokamaks are characterized by steep gradient of the radial electric field, and sonic poloidal U{sub p,m} flow that consists of poloidal components of the E×B flow and the plasma flow velocity that is parallel to the magnetic field B. Here, E is the electric field. The bootstrap current that is important for the equilibrium, and stability of the pedestal of H-mode plasmas is shown to have an expression different from that in the conventional theory. In the limit where ‖U{sub p,m}‖≫ 1, the bootstrap current is driven by the electron temperature gradient and inductive electric field fundamentally different from that in the conventional theory. The bootstrap current in the pedestal region can be controlled through manipulating U{sub p,m} and the gradient of the radial electric. This, in turn, can control plasma stability such as edge-localized modes. Quantitative evaluations of various coefficients are shown to illustrate that the bootstrap current remains finite when ‖U{sub p,m}‖ approaches infinite and to provide indications how to control the bootstrap current. Approximate analytic expressions for viscous coefficients that join results in the banana and plateau-Pfirsch-Schluter regimes are presented to facilitate bootstrap and neoclassical transport simulations in the pedestal region.

  8. Mean reversion in the current account of forty-eight african countries: Evidence from the Panel SURADF test

    Science.gov (United States)

    Chu, Hsiao-Ping; Chang, Tsangyao; Chang, Hsu-Ling; Su, Chi-Wei; Yuan, Young

    2007-10-01

    Here, the Panel seemingly unrelated regressions augmented Dickey-Fuller test (SURADF) test, first introduced and advanced by Breuer et al. [Misleading inferences from panel unit-root tests with an illustration from purchasing power parity, Rev. Int. Econ. 9(3) (2001) 482-493], is used to investigate the mean-reverting behavior of the current account of 48 African countries during the 1980-2004 periods. The empirical results from numerous panel-based unit root tests, conducted earlier, indicated that the current account of each of these countries is stationary; however, when Breuer et al.'s (2001) Panel SURADF test is conducted, it is found that a unit root exists in the current account of 11 of the countries studied. These results have one extremely important policy implication for the 48 African countries studied: the current account deficit of most is sustainable, and thus signifying that those nations should have no incentive to default on their international debt.

  9. Real-time control for long ohmic alternate current discharges

    International Nuclear Information System (INIS)

    Carvalho, Ivo S.; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Hekkert, Tiago; Carvalho, Bernardo B.; Gomes, Rui B.

    2014-01-01

    Highlights: • 40 Alternate plasma current (AC) semi-cycles without loss of ionization, more than 1 s of operation. • AC discharges automatic control: feedback loops, time-windows control strategy, goal oriented time-windows and exception handling. • Energy deposition and Carbon radiation evolution during the AC discharges. - Abstract: The ISTTOK tokamak has a long tradition on alternate plasma current (AC) discharges, but the old control system was limiting and lacked full system integration. In order to improve the AC discharges performance the ISTTOK fast control system was updated. This control system developed on site based on the Advanced Telecommunications Computing Architecture (ATCA) standard now integrates the information gathered by all the tokamak real-time diagnostics to produce an accurate observation of the plasma parameters. The real-time actuators were also integrated, allowing a Multiple Input Multiple Output (MIMO) control environment with several synchronization strategies available. The control system software was developed in C++ on top of a Linux system with the Multi-threaded Application Real-Time executor (MARTe) Framework to synchronize the real-time code execution under a 100μs control cycle. In addition, to simplify the discharge programming, a visual Human–Machine Interface (HMI) was also developed using the BaseLib2 libraries included in the MARTe Framework. This paper presents the ISTTOK control system and the optimizations that extended the AC current discharges duration to more than 1 s, corresponding to 40 semi-cycles without apparent degradation of the plasma parameters. This upgrade allows ISTTOK to be used as a low-cost material testing facility with long time exposures to nuclear fusion relevant plasmas, comparable (in duration) with medium size tokamaks

  10. Real-time control for long ohmic alternate current discharges

    Energy Technology Data Exchange (ETDEWEB)

    Carvalho, Ivo S., E-mail: ivoc@ipfn.ist.utl.pt; Duarte, Paulo; Fernandes, Horácio; Valcárcel, Daniel F.; Carvalho, Pedro J.; Silva, Carlos; Duarte, André S.; Neto, André; Sousa, Jorge; Batista, António J.N.; Hekkert, Tiago; Carvalho, Bernardo B.; Gomes, Rui B.

    2014-05-15

    Highlights: • 40 Alternate plasma current (AC) semi-cycles without loss of ionization, more than 1 s of operation. • AC discharges automatic control: feedback loops, time-windows control strategy, goal oriented time-windows and exception handling. • Energy deposition and Carbon radiation evolution during the AC discharges. - Abstract: The ISTTOK tokamak has a long tradition on alternate plasma current (AC) discharges, but the old control system was limiting and lacked full system integration. In order to improve the AC discharges performance the ISTTOK fast control system was updated. This control system developed on site based on the Advanced Telecommunications Computing Architecture (ATCA) standard now integrates the information gathered by all the tokamak real-time diagnostics to produce an accurate observation of the plasma parameters. The real-time actuators were also integrated, allowing a Multiple Input Multiple Output (MIMO) control environment with several synchronization strategies available. The control system software was developed in C++ on top of a Linux system with the Multi-threaded Application Real-Time executor (MARTe) Framework to synchronize the real-time code execution under a 100μs control cycle. In addition, to simplify the discharge programming, a visual Human–Machine Interface (HMI) was also developed using the BaseLib2 libraries included in the MARTe Framework. This paper presents the ISTTOK control system and the optimizations that extended the AC current discharges duration to more than 1 s, corresponding to 40 semi-cycles without apparent degradation of the plasma parameters. This upgrade allows ISTTOK to be used as a low-cost material testing facility with long time exposures to nuclear fusion relevant plasmas, comparable (in duration) with medium size tokamaks.

  11. Concepts Concerning 'Disease\\' Causation, Control, and the current ...

    African Journals Online (AJOL)

    There is an ethical necessity that doctors understand the complex social, political, environmental and economic dynamics involved in infectious disease outbreaks. This article discusses some important concepts concerning 'disease' causation and control with specific reference to the current cholera outbreak in Zimbabwe ...

  12. High performance current controller for particle accelerator magnets supply

    DEFF Research Database (Denmark)

    Maheshwari, Ram Krishan; Bidoggia, Benoit; Munk-Nielsen, Stig

    2013-01-01

    The electromagnets in modern particle accelerators require high performance power supply whose output is required to track the current reference with a very high accuracy (down to 50 ppm). This demands very high bandwidth controller design. A converter based on buck converter topology is used...

  13. Management and employee control in current industrial work

    DEFF Research Database (Denmark)

    Holt, Helle; Hvid, Helge

    2014-01-01

    This article examines how employee control is affected by the ongoing erosion of boundaries in work organization and established boundaries in the relationship between employees and management. One assumption is that the erosion of boundaries offers potential for increased employee control, meaning...... increased autonomy or self-determination at work (employee control how and when to do what). This assumption is supported by theories on the psychosocial working environment. Another assumption is that the erosion of boundaries threatens the frontiers from where employees can defend their interests......, and consequently reduces employees’ control of their work (what and how much to do). This assumption is supported by “labor process theory.” This article studies control and the erosion of boundaries in two case factories in the food industry. Two perspectives are applied: the psychosocial working environment...

  14. Management and employee control in current industrial work

    DEFF Research Database (Denmark)

    Holt, Helle; Hvid, Helge

    2014-01-01

    , and consequently reduces employees’ control of their work (what and how much to do). This assumption is supported by “labor process theory.” This article studies control and the erosion of boundaries in two case factories in the food industry. Two perspectives are applied: the psychosocial working environment......This article examines how employee control is affected by the ongoing erosion of boundaries in work organization and established boundaries in the relationship between employees and management. One assumption is that the erosion of boundaries offers potential for increased employee control, meaning...... increased autonomy or self-determination at work (employee control how and when to do what). This assumption is supported by theories on the psychosocial working environment. Another assumption is that the erosion of boundaries threatens the frontiers from where employees can defend their interests...

  15. Controlling chaos in the current-driven ion acoustic instability

    International Nuclear Information System (INIS)

    Fukuyama, T.; Taniguchi, K.; Kawai, Y.

    2002-01-01

    Control of intermittent chaos caused by the current-driven ion acoustic instability is attempted and the controlling mechanism is investigated. When a small negative dc voltage is applied to the chaotic system as a perturbation, the system changes from a chaotic state to a periodic state while maintaining the instability, indicating that the chaotic state caused by the ion acoustic instability is well controlled by applying a small negative dc voltage. A hysteresis structure is observed on the V-I curve of the mesh grid to which the negative dc voltage to control is applied. Furthermore, when a negative dc voltage is applied to the state which shows a laminar structure existing under same experimental conditions, the system becomes chaotic via a bifurcation. Driven-chaos is excited when a negative dc voltage is applied to the laminar state. Applying a small negative dc voltage leads to controlling intermittent chaos while exciting driven-chaos

  16. Means and method for controlling the neutron output of a neutron generator tube

    International Nuclear Information System (INIS)

    Langford, O.M.; Peelman, H.E.

    1980-01-01

    A gas filled neutron tube in a nuclear well logging tool has a target an ion source voltage and a replenisher connected to ground. A negative high voltage is applied to the target by a power supply also providing a target current corresponding to the neutron output of the neutron generator tube. A constant current source provides a constant current. A network receiving the target current and the constant current provides a portion of the constant current as a replenisher current which is applied to the replenisher in a neutron generating tube. The network controls the magnitude of the replenisher current in accordance with the target current so as to control the neutron output of the neutron generating tube. (auth)

  17. Current control of PMSM based on maximum torque control reference frame

    Science.gov (United States)

    Ohnuma, Takumi

    2017-07-01

    This study presents a new method of current controls of PMSMs (Permanent Magnet Synchronous Motors) based on a maximum torque control reference frame, which is suitable for high-performance controls of the PMSMs. As the issues of environment and energy increase seriously, PMSMs, one of the AC motors, are becoming popular because of their high-efficiency and high-torque density in various applications, such as electric vehicles, trains, industrial machines, and home appliances. To use the PMSMs efficiently, a proper current control of the PMSMs is necessary. In general, a rotational coordinate system synchronizing with the rotor is used for the current control of PMSMs. In the rotating reference frame, the current control is easier because the currents on the rotating reference frame can be expressed as a direct current in the controller. On the other hand, the torque characteristics of PMSMs are non-linear and complex; the PMSMs are efficient and high-density though. Therefore, a complicated control system is required to involve the relation between the torque and the current, even though the rotating reference frame is adopted. The maximum torque control reference frame provides a simpler way to control efficiently the currents taking the torque characteristics of the PMSMs into consideration.

  18. Design and implementation of predictive current control of three-phase PWM rectifier using space-vector modulation (SVM)

    International Nuclear Information System (INIS)

    Bouafia, Abdelouahab; Gaubert, Jean-Paul; Krim, Fateh

    2010-01-01

    This paper is concerned with the design and implementation of current control of three-phase PWM rectifier based on predictive control strategy. The proposed predictive current control technique operates with constant switching frequency, using space-vector modulation (SVM). The main goal of the designed current control scheme is to maintain the dc-bus voltage at the required level and to achieve the unity power factor (UPF) operation of the converter. For this purpose, two predictive current control algorithms, in the sense of deadbeat control, are developed for direct controlling input current vector of the converter in the stationary α-β and rotating d-q reference frame, respectively. For both predictive current control algorithms, at the beginning of each switching period, the required rectifier average voltage vector allowing the cancellation of both tracking errors of current vector components at the end of the switching period, is computed and applied during a predefined switching period by means of SVM. The main advantages of the proposed predictive current control are that no need to use hysteresis comparators or PI controllers in current control loops, and constant switching frequency. Finally, the developed predictive current control algorithms were tested both in simulations and experimentally, and illustrative results are presented here. Results have proven excellent performance in steady and transient states, and verify the validity of the proposed predictive current control which is compared to other control strategies.

  19. Control of optically induced currents in semiconductor crystals

    Energy Technology Data Exchange (ETDEWEB)

    Kohli, Kapil Kumar

    2010-06-01

    The generation and control of optically induced currents has the potential to become an important building block for optical computers. Here, shift and rectification currents are investigated that emerge from a divergence of the optical susceptibility. It is known that these currents react to the shape of the impinging laser pulse, and especially to the shape of the pulse envelope. The main goal is the systematic manipulation of the pulse envelope with an optical pulse shaper that is integrated into a standard THz emission setup. The initial approach, the chirping of the laser pulse only has a weak influence on the envelope and the currents. Instead, a second approach is suggested that uses the combined envelope of a phase-stable pulse-pair as a parameter. In a laser pulse, the position of the maxima of the electrical field and the pulse envelope are shifted relative to each other. This shift is known as the Carrier-Envelope Phase (CEP). It is a new degree of freedom that is usually only accessible in specially stabilized systems. It is shown, that in a phase-stable pulse-pair, at least the relative CEP is usable as a new degree of freedom. It has a great influence on the shape of the pulse envelope and thus on the current density. It is shown that this approach enables the coherent control of the current density. The experiments are corroborated by a theoretical model of the system. The potential of this approach is demonstrated in an application. A framework is presented that uses an iterative genetic algorithm to create arbitrarily shaped THz traces. The algorithm controls the optical pulse shaper, and varies the phase of the impinging laser pulses until the desired target trace is found. (orig.)

  20. HOM frequency control of SRF cavity in high current ERLs

    Science.gov (United States)

    Xu, Chen; Ben-Zvi, Ilan

    2018-03-01

    The acceleration of high-current beam in Superconducting Radio Frequency (SRF) cavities is a challenging but essential for a variety of advanced accelerators. SRF cavities should be carefully designed to minimize the High Order Modes (HOM) power generated in the cavities by the beam current. The reduction of HOM power we demonstrate in a particular case can be quite large. This paper presents a method to systematically control the HOM resonance frequencies in the initial design phase to minimize the HOM power generation. This method is expected to be beneficial for the design of high SRF cavities addressing a variety of Energy Recovery Linac (ERL) applications.

  1. Geodetic Control Points, Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level elevations have been determined., Published in 1995, 1:24000 (1in=2000ft) scale, Rhode Island and Providence Plantations.

    Data.gov (United States)

    NSGIC State | GIS Inventory — Geodetic Control Points dataset current as of 1995. Benchmarks; Vertical elevation bench marks for monumented geodetic survey control points for which mean sea level...

  2. Myoelectric hand prosthesis force control through servo motor current feedback.

    Science.gov (United States)

    Sono, Tálita Saemi Payossim; Menegaldo, Luciano Luporini

    2009-10-01

    This paper presents the prehension force closed-loop control design of a mechanical finger commanded by electromyographic signal (EMG) from a patient's arm. The control scheme was implemented and tested in a mechanical finger prototype with three degrees of freedom and one actuator, driven by arm muscles EMG of normal volunteers. Real-time indirect estimation of prehension force was assessed by measuring the DC servo motor actuator current. A model of the plant comprising finger, motor, and grasped object was proposed. Model parameters were identified experimentally and a classical feedback phase-lead compensator was designed. The controlled mechanical finger was able to provide a more accurate prehension force modulation of a compliant object when compared to open-loop control.

  3. Frequency-Controlled Current-Fed Resonant Converter with No Input Ripple Current

    Directory of Open Access Journals (Sweden)

    Bor-Ren Lin

    2018-02-01

    Full Text Available This paper studies a frequency-controlled current-fed resonant circuit. The adopted direct current (DC-to-DC converter contains two boost circuits and a resonant circuit on the primary side. First, two boost circuits are connected in parallel to achieve voltage step-up and reduce input ripple current by using interleaved pulse-width modulation. Therefore, the size and current rating of boost inductors are decreased in the proposed converter. Second, the boost voltage is connected to the resonant circuit to realize the mechanism of the zero-voltage switching of all active switches and zero-current switching of all diodes. Two boost circuits and a resonant circuit use the same power devices in order to lessen the switch counts. The voltage doubler topology is adopted on the secondary side (high-voltage side. Therefore, the voltage rating of diodes on the high-voltage side is clamped at output voltage. The feasibility of the studied circuit is confirmed by the experimental tests with a 1 kW prototype circuit.

  4. Electric Machine with Boosted Inductance to Stabilize Current Control

    Science.gov (United States)

    Abel, Steve

    2013-01-01

    High-powered motors typically have very low resistance and inductance (R and L) in their windings. This makes the pulse-width modulated (PWM) control of the current very difficult, especially when the bus voltage (V) is high. These R and L values are dictated by the motor size, torque (Kt), and back-emf (Kb) constants. These constants are in turn set by the voltage and the actuation torque-speed requirements. This problem is often addressed by placing inductive chokes within the controller. This approach is undesirable in that space is taken and heat is added to the controller. By keeping the same motor frame, reducing the wire size, and placing a correspondingly larger number of turns in each slot, the resistance, inductance, torque constant, and back-emf constant are all increased. The increased inductance aids the current control but ruins the Kt and Kb selections. If, however, a fraction of the turns is moved from their "correct slot" to an "incorrect slot," the increased R and L values are retained, but the Kt and Kb values are restored to the desired values. This approach assumes that increased resistance is acceptable to a degree. In effect, the heat allocated to the added inductance has been moved from the controller to the motor body, which in some cases is preferred.

  5. Stator Current Harmonic Control with Resonant Controller for Doubly Fed Induction Generator

    DEFF Research Database (Denmark)

    Liu, Changjin; Blaabjerg, Frede; Chen, Wenjie

    2012-01-01

    rotor current control loop for harmonic suppression. The overall control scheme is implemented in dq frame. Based on a mathematical model of the DFIG control system, the effects on system stability using the resonant controller, an analysis of the steady-state error, and the dynamic performance......, are discussed in this paper. Taking these effects into account, the parameters of the resonant controller can be designed and effectively damp the influence from the grid voltage harmonics. As a result, the impacts of the negative sequence fifth- and positive sequence seventh-order voltage harmonics...... harmonics, especially low-order harmonics. This paper proposes a stator current harmonic suppression method using a sixth-order resonant controller to eliminate negative sequence fifth- and positive sequence seventh-order current harmonics. A stator current harmonic control loop is added to the conventional...

  6. Existence of optimal controls for systems governed by mean-field ...

    African Journals Online (AJOL)

    In this paper, we study the existence of an optimal control for systems, governed by stochastic dierential equations of mean-eld type. For non linear systems, we prove the existence of an optimal relaxed control, by using tightness techniques and Skorokhod selection theorem. The optimal control is a measure valued process ...

  7. Cancer pain and current theory for pain control.

    Science.gov (United States)

    Kahan, Brian

    2014-05-01

    This article discusses current trends in managing cancer pain, with specific regard to opioid transmission, descending pathway inhabitation, and ways to facilitate the endogenous antinociceptive chemicals in the human body. Various techniques for opioid and nonopioid control of potential pain situations of patients with cancer are discussed. The benefits of using pharmacogenetics to assess the appropriate medications are addressed. Finally, specific treatment of abdominal cancer pain using radiofrequency lesioning is discussed. Copyright © 2014 Elsevier Inc. All rights reserved.

  8. Controlling the emission current from a plasma cathode

    International Nuclear Information System (INIS)

    Bagaev, S.P.; Gushenets, V.I.; Schanin, P.M.

    1993-01-01

    The processes determining the time and amplitude characteristics of the grid-controlled electron emission from the plasma of an arc discharge have been analyzed. It has been shown that by applying to the grid confining the plasma emission boundary of a modulated voltage it is possible to form current pulse of up to 1 kA with nanosecond risetimes and falltimes and a pulse repetitive rate of 100 kHz

  9. Shear optimization experiments with current profile control on JET

    International Nuclear Information System (INIS)

    1997-01-01

    A record performance on JET has been obtained with shear optimization scenarios. A neutron yield of 5.6x10 16 s -1 in deuterium discharges, and a global energy confinement improvement above the ITER-89 L-mode scaling with H ≤ 2.5 in L-mode and H ≤ 3 in H-mode have been achieved. The tailoring of plasma current, density and heating power waveforms and current profile control with lower hybrid current drive and ICRF phasing have been essential. Internal energy, particle and momentum transport barriers develop spontaneously upon heating above a threshold power of about 15 MW with neutral beams and ICRH into a low-density target plasma, with a wide central region of slightly negative or flat magnetic shear with q > 1 everywhere. An additional H-mode transition can also raise the pressure in the region between internal and edge transport barriers. The ion heat conductivity falls to the neoclassical level in the improved core confinement region. Pressure profile control through power deposition feedback control makes it possible to work close to the marginal stability boundary for pressure-driven MHD modes. First experiments in deuterium/tritium plasmas, with up to 75% tritium target concentration, have established internal transport barriers already with heating powers at the lowest threshold of pure deuterium plasmas, resulting in a fusion power output of P fusion = 2 MW. (author)

  10. Current standards for infection control: audit assures compliance.

    Science.gov (United States)

    Flanagan, Pauline

    Having robust policies and procedures in place for infection control is fundamentally important. However, each organization has to go a step beyond this; evidence has to be provided that these policies and procedures are followed. As of 1 April 2009, with the introduction of the Care Quality Commission and The Health and Social Care Act 2008 Code of Practice for the NHS on the Prevention and Control of Healthcare-Associated Infections and Related Guidance, the assurance of robust infection control measures within any UK provider of health care became an even higher priority. Also, the commissioning of any service by the NHS must provide evidence that the provider has in place robust procedures for infection control. This article demonstrates how the clinical audit team at the Douglas Macmillan Hospice in North Staffordshire, UK, have used audit to assure high rates of compliance with the current national standards for infection control. Prior to the audit, hospice staff had assumed that the rates of compliance for infection control approached 100%. This article shows that a good quality audit tool can be used to identify areas of shortfall in infection control and the effectiveness of putting in place an action plan followed by re-audit.

  11. Linear Quadratic Mean Field Type Control and Mean Field Games with Common Noise, with Application to Production of an Exhaustible Resource

    Energy Technology Data Exchange (ETDEWEB)

    Graber, P. Jameson, E-mail: jameson-graber@baylor.edu [Baylor University, Department of Mathematics (United States)

    2016-12-15

    We study a general linear quadratic mean field type control problem and connect it to mean field games of a similar type. The solution is given both in terms of a forward/backward system of stochastic differential equations and by a pair of Riccati equations. In certain cases, the solution to the mean field type control is also the equilibrium strategy for a class of mean field games. We use this fact to study an economic model of production of exhaustible resources.

  12. Two-section linear direct-current accelerator of 1.2 MeV electrons. Mean beam current of 50 mA

    International Nuclear Information System (INIS)

    Alimov, A.S.; Ermakov, D.I.; Ishkhanov, B.S.; Shvedunov, V.I.; Sakharov, V.P.; Trower, W.P.

    2002-01-01

    The theoretical and experimental results, obtained by simulation, creation and start-up of the two-section linear electron accelerator, are presented. The following beam parameters: beam current of 49 mA, mean energy of 1.2 MeV, of 59 kV, normalized emittance of 11 mm mrad are determined on the basis of the data on the beam dynamics simulation and the accelerating structure optimization. Special attention is paid to the choice of the version of the SHF-supply system of the two-section accelerator. The version of the SHF-supply system, based on the sections phasing, operating in the auto-oscillation model by means of the synchronizing signal from the feedback chain of the first section into the feedback chain of the second section, is considered. The electron beam parameters on the accelerator outlet (beam current - 44 mA, beam energy - 1.15 MeV, beam efficiency - 50.6 kW) proved to be close to the simulation results [ru

  13. Dynamics and stabilization of peak current-mode controlled buck converter with constant current load

    Science.gov (United States)

    Leng, Min-Rui; Zhou, Guo-Hua; Zhang, Kai-Tun; Li, Zhen-Hua

    2015-10-01

    The discrete iterative map model of peak current-mode controlled buck converter with constant current load (CCL), containing the output voltage feedback and ramp compensation, is established in this paper. Based on this model the complex dynamics of this converter is investigated by analyzing bifurcation diagrams and the Lyapunov exponent spectrum. The effects of ramp compensation and output voltage feedback on the stability of the converter are investigated. Experimental results verify the simulation and theoretical analysis. The stability boundary and chaos boundary are obtained under the theoretical conditions of period-doubling bifurcation and border collision. It is found that there are four operation regions in the peak current-mode controlled buck converter with CCL due to period-doubling bifurcation and border-collision bifurcation. Research results indicate that ramp compensation can extend the stable operation range and transfer the operating mode, and output voltage feedback can eventually eliminate the coexisting fast-slow scale instability. Project supported by the National Natural Science Foundation of China (Grant No. 61371033), the Fok Ying-Tung Education Foundation for Young Teachers in the Higher Education Institutions of China (Grant No. 142027), the Sichuan Provincial Youth Science and Technology Fund, China (Grant Nos. 2014JQ0015 and 2013JQ0033), and the Fundamental Research Funds for the Central Universities, China (Grant No. SWJTU11CX029).

  14. Two-dimensional effects in the problem of tearing modes control by electron cyclotron current drive

    International Nuclear Information System (INIS)

    Comisso, L.; Lazzaro, E.

    2010-01-01

    The design of means to counteract robustly the classical and neoclassical tearing modes in a tokamak by localized injection of an external control current requires an ever growing understanding of the physical process, beyond the Rutherford-type zero-dimensional models. Here a set of extended magnetohydrodynamic nonlinear equations for four continuum fields is used to investigate the two-dimensional effects in the response of the reconnecting modes to specific inputs of the localized external current. New information is gained on the space- and time-dependent effects of the external action on the two-dimensional structure of magnetic islands, which is very important to formulate applicable control strategies.

  15. Prevention and control of schistosomiasis: a current perspective

    Directory of Open Access Journals (Sweden)

    Inobaya MT

    2014-10-01

    Full Text Available Marianette T Inobaya,1 Remigio M Olveda,1 Thao NP Chau,3 David U Olveda,2 Allen GP Ross21Department of Health, Research Institute for Tropical Medicine, Muntinlupa City, Philippines; 2Griffith Health Institute, School of Medical Sciences, Gold Coast Campus, Griffith University, Southport, Australia; 3Discipline of Public Health, Flinders University, Adelaide, AustraliaAbstract: Schistosomiasis is a neglected tropical disease that ranks second only to malaria in terms of human suffering in the tropics and subtropics. Five species are known to infect man and there are currently over 240 million people infected worldwide. The cornerstone of control to date has been mass drug administration with 40 mg/kg of praziquantel but there are problems with this approach. Human and bovine vaccines are in various stages of development. Integrated control, targeting the life cycle, is the only approach that will lead to sustainability and future elimination.Keywords: schistosomiais, morbidity, treatment and control, mass drug administration

  16. Improved control strategy for PI-R current of DFIG considering voltage and current harmonics compensation

    Science.gov (United States)

    Song, S. Y.; Liu, Q. H.; Zhao, Y. N.; Liu, S. Y.

    2016-08-01

    With the rapid development of wind power generation, the related research of wind power control and integration issues has attracted much attention, and the focus of the research are shifting away from the ideal power grid environment to the actual power grid environment. As the main stream wind turbine generator, a doubly-fed induction generator (DFIG) is connected to the power grid directly by its stator, so it is particularly sensitive to the power grid. This paper studies the improvement of DFIG control technology in the power grid harmonic environment. Based on the DFIG dynamic model considering the power grid harmonic environment, this paper introduces the shortcomings of the common control strategy of DFIG, and puts forward the enhanced method. The decoupling control of the system is realized by compensating the coupling between the rotor harmonic voltage and harmonic current, improving the control performance. In addition, the simulation experiments on PSCAD/EMTDC are carried out to verify the correctness and effectiveness of the improved scheme.

  17. Current Approaches for Control Room I and C Modernization

    International Nuclear Information System (INIS)

    Lopez, Alberto; Jimenez, Alfonso

    2002-01-01

    In general, instrumentation and control (I and C) systems for nuclear power plants were made using analogic systems and relays, since this was the only technology available by the time these systems were designed. This fact impacts on the operational and maintenance capabilities required to these systems. For this reason, nuclear power plants are facing nowadays two challenges: on one hand, the obsolescence of these systems contributes to the increase in the operation and maintenance costs - due to the difficulties for getting spare parts and support from the system vendors -. On the other hand, there has been an increase in the utilities competitiveness due to the electric power market liberalization. All this, of course, along with the commitment to maintain the current safety levels and meet the new requirements and standards that may arise in the near future. The application of current technologies, especially digital technology, solves the obsolescence problems and allows for a more functional and updated human-machine interface. Nevertheless, the cost associated to these modifications makes it necessary to develop strategies to determine which systems need to be modified and how to implement modifications effectively, so that these systems can work jointly with others using different technologies. Other issues inherent to digital technology must be considered, such as verification and validation of the software and of the human-machine interface, which are required for its licensing. This presentation describes the current approaches for I and C modernization, the main reasons, technologies and implementation plans, focusing on the control room and on the impact on operations. The main issues to be considered for developing a specific modernization plan are analysed. The goals and status of the 'Feasibility Study of the Control Room I and C Modernization' are described. This study is currently being developed by Endesa, Iberdrola and Tecnatom, and is included

  18. TEMPERATURE CONTROL OF A CONTINUOUS STIRRED TANK REACTOR BY MEANS OF TWO DIFFERENT INTELLIGENT STRATEGIES

    OpenAIRE

    Rahmat, Mohd Fua'ad; Yazdani, Amir Mehdi; Movahed, Mohammad Ahmadi; Mahmoudzadeh, Somaiyeh

    2011-01-01

    Continues Stirred Tank Reactor (CSTR) is an important subject in chemical process and offering a diverse range of researches in the area of the chemical and control engineering. Various control approaches have been applied on CSTR to control its parameters. This paper presents two different control strategies based on the combination of a novel socio-political optimization algorithm, called Imperialist Competitive Algorithm (ICA), and concept of the gain scheduling performed by means of the l...

  19. Computation of antenna pattern correlation and MIMO performance by means of surface current distribution and spherical wave theory

    Directory of Open Access Journals (Sweden)

    O. Klemp

    2006-01-01

    Full Text Available In order to satisfy the stringent demand for an accurate prediction of MIMO channel capacity and diversity performance in wireless communications, more effective and suitable models that account for real antenna radiation behavior have to be taken into account. One of the main challenges is the accurate modeling of antenna correlation that is directly related to the amount of channel capacity or diversity gain which might be achieved in multi element antenna configurations. Therefore spherical wave theory in electromagnetics is a well known technique to express antenna far fields by means of a compact field expansion with a reduced number of unknowns that was recently applied to derive an analytical approach in the computation of antenna pattern correlation. In this paper we present a novel and efficient computational technique to determine antenna pattern correlation based on the evaluation of the surface current distribution by means of a spherical mode expansion.

  20. Estimate of the global-scale joule heating rates in the thermosphere due to time mean currents

    International Nuclear Information System (INIS)

    Roble, R.G.; Matsushita, S.

    1975-01-01

    An estimate of the global-scale joule heating rates in the thermosphere is made based on derived global equivalent overhead electric current systems in the dynamo region during geomagnetically quiet and disturbed periods. The equivalent total electric field distribution is calculated from Ohm's law. The global-scale joule heating rates are calculated for various monthly average periods in 1965. The calculated joule heating rates maximize at high latitudes in the early evening and postmidnight sectors. During geomagnetically quiet times the daytime joule heating rates are considerably lower than heating by solar EUV radiation. However, during geomagnetically disturbed periods the estimated joule heating rates increase by an order of magnitude and can locally exceed the solar EUV heating rates. The results show that joule heating is an important and at times the dominant energy source at high latitudes. However, the global mean joule heating rates calculated near solar minimum are generally small compared to the global mean solar EUV heating rates. (auth)

  1. Simple control law structure for the control of airplanes by means of their engines

    OpenAIRE

    Fezans, Nicolas

    2011-01-01

    In this paper a simple control law structure is presented for the control of airplanes using only the engines' thrust. For the design of such a propulsion controlled aircraft control law, the approach followed in this work is to look for the right level of performance in order to avoid both excessive engines activity and reduction of robustness properties. Another goal is to keep the control law and its tuning as simple as possible: for this a control law structure whose terms can easily be i...

  2. A Stochastic Maximum Principle for Risk-Sensitive Mean-Field Type Control

    KAUST Repository

    Djehiche, Boualem; Tembine, Hamidou; Tempone, Raul

    2015-01-01

    In this paper we study mean-field type control problems with risk-sensitive performance functionals. We establish a stochastic maximum principle (SMP) for optimal control of stochastic differential equations (SDEs) of mean-field type, in which the drift and the diffusion coefficients as well as the performance functional depend not only on the state and the control but also on the mean of the distribution of the state. Our result extends the risk-sensitive SMP (without mean-field coupling) of Lim and Zhou (2005), derived for feedback (or Markov) type optimal controls, to optimal control problems for non-Markovian dynamics which may be time-inconsistent in the sense that the Bellman optimality principle does not hold. In our approach to the risk-sensitive SMP, the smoothness assumption on the value-function imposed in Lim and Zhou (2005) needs not be satisfied. For a general action space a Peng's type SMP is derived, specifying the necessary conditions for optimality. Two examples are carried out to illustrate the proposed risk-sensitive mean-field type SMP under linear stochastic dynamics with exponential quadratic cost function. Explicit solutions are given for both mean-field free and mean-field models.

  3. A Stochastic Maximum Principle for Risk-Sensitive Mean-Field Type Control

    KAUST Repository

    Djehiche, Boualem

    2015-02-24

    In this paper we study mean-field type control problems with risk-sensitive performance functionals. We establish a stochastic maximum principle (SMP) for optimal control of stochastic differential equations (SDEs) of mean-field type, in which the drift and the diffusion coefficients as well as the performance functional depend not only on the state and the control but also on the mean of the distribution of the state. Our result extends the risk-sensitive SMP (without mean-field coupling) of Lim and Zhou (2005), derived for feedback (or Markov) type optimal controls, to optimal control problems for non-Markovian dynamics which may be time-inconsistent in the sense that the Bellman optimality principle does not hold. In our approach to the risk-sensitive SMP, the smoothness assumption on the value-function imposed in Lim and Zhou (2005) needs not be satisfied. For a general action space a Peng\\'s type SMP is derived, specifying the necessary conditions for optimality. Two examples are carried out to illustrate the proposed risk-sensitive mean-field type SMP under linear stochastic dynamics with exponential quadratic cost function. Explicit solutions are given for both mean-field free and mean-field models.

  4. Precision electronic speed controller for an alternating-current motor

    Science.gov (United States)

    Bolie, V.W.

    A high precision controller for an alternating-current multi-phase electrical motor that is subject to a large inertial load. The controller was developed for controlling, in a neutron chopper system, a heavy spinning rotor that must be rotated in phase-locked synchronism with a reference pulse train that is representative of an ac power supply signal having a meandering line frequency. The controller includes a shaft revolution sensor which provides a feedback pulse train representative of the actual speed of the motor. An internal digital timing signal generator provides a reference signal which is compared with the feedback signal in a computing unit to provide a motor control signal. The motor control signal is a weighted linear sum of a speed error voltage, a phase error voltage, and a drift error voltage, each of which is computed anew with each revolution of the motor shaft. The speed error signal is generated by a novel vernier-logic circuit which is drift-free and highly sensitive to small speed changes. The phase error is also computed by digital logic, with adjustable sensitivity around a 0 mid-scale value. The drift error signal, generated by long-term counting of the phase error, is used to compensate for any slow changes in the average friction drag on the motor. An auxillary drift-byte status sensor prevents any disruptive overflow or underflow of the drift-error counter. An adjustable clocked-delay unit is inserted between the controller and the source of the reference pulse train to permit phase alignment of the rotor to any desired offset angle. The stator windings of the motor are driven by two amplifiers which are provided with input signals having the proper quadrature relationship by an exciter unit consisting of a voltage controlled oscillator, a binary counter, a pair of read-only memories, and a pair of digital-to-analog converters.

  5. Current vector control challenges in the fight against malaria.

    Science.gov (United States)

    Benelli, Giovanni; Beier, John C

    2017-10-01

    The effective and eco-friendly control of Anopheles vectors plays a key role in any malaria management program. Integrated Vector Management (IVM) suggests making use of the full range of vector control tools available. The strategies for IVM require novel technologies to control outdoor transmission of malaria. Despite the wide number of promising control tools tested against mosquitoes, current strategies for malaria vector control used in most African countries are not sufficient to achieve successful malaria control. The majority of National Malaria Control Programs in Africa still rely on indoor residual spraying (IRS) and long-lasting insecticidal nets (LLINs). These methods reduce malaria incidence but generally have little impact on malaria prevalence. In addition to outdoor transmission, growing levels of insecticide resistance in targeted vectors threaten the efficacy of LLINs and IRS. Larvicidal treatments can be useful, but are not recommended for rural areas. The research needed to improve the quality and delivery of mosquito vector control should focus on (i) optimization of processes and methods for vector control delivery; (ii) monitoring of vector populations and biting activity with reliable techniques; (iii) the development of effective and eco-friendly tools to reduce the burden or locally eliminate malaria and other mosquito-borne diseases; (iv) the careful evaluation of field suitability and efficacy of new mosquito control tools to prove their epidemiological impact; (v) the continuous monitoring of environmental changes which potentially affect malaria vector populations; (vi) the cooperation among different disciplines, with main emphasis on parasitology, tropical medicine, ecology, entomology, and ecotoxicology. A better understanding of behavioral ecology of malaria vectors is required. Key ecological obstacles that limit the effectiveness of vector control include the variation in mosquito behavior, development of insecticide resistance

  6. A simplified controller and detailed dynamics of constant off-time peak current control

    Science.gov (United States)

    Van den Bossche, Alex; Dimitrova, Ekaterina; Valchev, Vencislav; Feradov, Firgan

    2017-09-01

    A fast and reliable current control is often the base of power electronic converters. The traditional constant frequency peak control is unstable above 50 % duty ratio. In contrast, the constant off-time peak current control (COTCC) is unconditionally stable and fast, so it is worth analyzing it. Another feature of the COTCC is that one can combine a current control together with a current protection. The time dynamics show a zero-transient response, even when the inductor changes in a wide range. It can also be modeled as a special transfer function for all frequencies. The article shows also that it can be implemented in a simple analog circuit using a wide temperature range IC, such as the LM2903, which is compatible with PV conversion and automotive temperature range. Experiments are done using a 3 kW step-up converter. A drawback is still that the principle does not easily fit in usual digital controllers up to now.

  7. Two coupled Josephson junctions: dc voltage controlled by biharmonic current

    International Nuclear Information System (INIS)

    Machura, L; Spiechowicz, J; Kostur, M; Łuczka, J

    2012-01-01

    We study transport properties of two Josephson junctions coupled by an external shunt resistance. One of the junctions (say, the first) is driven by an unbiased ac current consisting of two harmonics. The device can rectify the ac current yielding a dc voltage across the first junction. For some values of coupling strength, controlled by an external shunt resistance, a dc voltage across the second junction can be generated. By variation of system parameters such as the relative phase or frequency of two harmonics, one can conveniently manipulate both voltages with high efficiency, e.g. changing the dc voltages across the first and second junctions from positive to negative values and vice versa. (paper)

  8. Diagnostic development for current density profile control at KSTAR

    Energy Technology Data Exchange (ETDEWEB)

    Ko, J., E-mail: jinseok@nfri.re.kr [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); University of Science and Technology, Daejeon 34113 (Korea, Republic of); Chung, J. [National Fusion Research Institute, Daejeon 34133 (Korea, Republic of); Messmer, M.C.C. [Department of Applied Physics, Eindhoven University of Technology, Eindhoven (Netherlands)

    2016-11-01

    Highlights: • The motional Stark effect (MSE) diagnostic installed at KSTAR. • Engineering challenges and solutions on the design and fabrication of the front optics housing and filter modules. • Characterization of the bandpass filters and the responses to polarized light. - Abstract: The current density profile diagnostics are critical for the control of the steady-state burning plasma operations. A multi-channel motional Stark effect (MSE) diagnostic system has been implemented for the measurements of the internal magnetic field structures that constrain the magnetic equilibrium reconstruction to accurately produce the tokamak safety factor and current density profiles for the Korea Superconducting Tokamak Advanced Research (KSTAR). This work presents the design and fabrication of the front optics and the filter modules and the calibration activities for the MSE diagnostic at KSTAR.

  9. A Harmonic Current Suppression Control Strategy for Droop-Controlled Inverter Connected to the Distorted Grid

    DEFF Research Database (Denmark)

    Wei, Feng; Sun, Kai; Guan, Yajuan

    2015-01-01

    currents. Therefore, the reason of generation of distorted grid-feeding current of GF-VCI under the distorted grid voltage is investigated firstly in this paper. Then, a harmonic grid-feeding current suppression control strategy for GF-VCI is proposed. Two different filters are compared and analysed before...... voltage component at the point of common coupling. As a result, the difference of harmonic voltage between PCC and GF-VCI is reduced and the THDi of grid feeding-currents is decreased. Finally, the proposed control strategy is verified through simulations and experimental results....

  10. Hierarchical Controlled Grid-Connected Microgrid based on a Novel Autonomous Current Sharing Controller

    DEFF Research Database (Denmark)

    Guan, Yajuan; Quintero, Juan Carlos Vasquez; Guerrero, Josep M.

    2015-01-01

    In this paper, a hierarchical control system based on a novel autonomous current sharing controller for grid-connected microgrids (MGs) is presented. A three-level hierarchical control system is implemented to guarantee the power sharing performance among voltage controlled parallel inverters......, while providing the required active and reactive power to the utility grid. A communication link is used to transmit the control signal from the tertiary and secondary control levels to the primary control. Simulation results from a MG based on two grid-connected parallel inverters are shown in order...

  11. Computer simulation of nuclear reactor control by means of heuristic learning controller

    International Nuclear Information System (INIS)

    Bubak, M.; Moscinski, J.

    1976-01-01

    A trial of application of two techniques of Artificial Intelligence: heuristic Programming and Learning Machines Theory for nuclear reactor control is presented. Considering complexity of the mathematical models describing satisfactorily the nuclear reactors, value changes of these models parameters in course of operation, knowledge of some parameters value with too small exactness, there appear diffucluties in the classical approach application for these objects control systems design. The classical approach consists in definition of the permissible control actions set on the base of the set performance index and the object mathematical model. The Artificial Intelligence methods enable construction of the control system, which gets during work an information being a priori inaccessible and uses it for its action change for the control to be the optimum one. Applying these methods we have elaborated the reactor power control system. As the performance index there has been taken the integral of the error square. For the control system there are only accessible: the set power trajectory, the reactor power and the control rod position. The set power trajectory has been divided into time intervals called heuristic intervals. At the beginning of every heuristic interval, on the base of the obtained experience, the control system chooses from the control (heuristic) set the optimum control. The heuristic set it is the set of relations between the control rod rate and the state variables, the set and the obtained power, similar to simplifications applied by nuclear reactors operators. The results obtained for the different control rod rates and different reactor (simulated on the digital computer) show the proper work of the system. (author)

  12. A Mean-Variance Criterion for Economic Model Predictive Control of Stochastic Linear Systems

    DEFF Research Database (Denmark)

    Sokoler, Leo Emil; Dammann, Bernd; Madsen, Henrik

    2014-01-01

    , the tractability of the resulting optimal control problem is addressed. We use a power management case study to compare different variations of the mean-variance strategy with EMPC based on the certainty equivalence principle. The certainty equivalence strategy is much more computationally efficient than the mean......-variance strategies, but it does not account for the variance of the uncertain parameters. Openloop simulations suggest that a single-stage mean-variance approach yields a significantly lower operating cost than the certainty equivalence strategy. In closed-loop, the single-stage formulation is overly conservative...... be modified to perform almost as well as the two-stage mean-variance formulation. Nevertheless, we argue that the mean-variance approach can be used both as a strategy for evaluating less computational demanding methods such as the certainty equivalence method, and as an individual control strategy when...

  13. A Decomposition Algorithm for Mean-Variance Economic Model Predictive Control of Stochastic Linear Systems

    DEFF Research Database (Denmark)

    Sokoler, Leo Emil; Dammann, Bernd; Madsen, Henrik

    2014-01-01

    This paper presents a decomposition algorithm for solving the optimal control problem (OCP) that arises in Mean-Variance Economic Model Predictive Control of stochastic linear systems. The algorithm applies the alternating direction method of multipliers to a reformulation of the OCP...

  14. A Novel Sliding Mode Control Technique for Indirect Current Controlled Active Power Filter

    Directory of Open Access Journals (Sweden)

    Juntao Fei

    2012-01-01

    Full Text Available A novel sliding mode control (SMC method for indirect current controlled three-phase parallel active power filter is presented in this paper. There are two designed closed loops in the system: one is the DC voltage controlling loop and the other is the reference current tracking loop. The first loop with a PI regulator is used to control the DC voltage approximating to the given voltage of capacitor, and the output of PI regulator through a low-pass filter is applied as the input of the power supply reference currents. The second loop implements the tracking of the reference currents using integral sliding mode controller, which can improve the harmonic treating performance. Compared with the direct current control technique, it is convenient to be implemented with digital signal processing system because of simpler system structure and better harmonic treating property. Simulation results verify that the generated reference currents have the same amplitude with the load currents, demonstrating the superior harmonic compensating effects with the proposed shunt active power filter compared with the hysteresis method.

  15. A novel current injection model of PWMSC for control and analysis of power system stability

    Directory of Open Access Journals (Sweden)

    Safari Amin

    2013-01-01

    Full Text Available This paper proposes a novel current injection model of Pulse width Modulation based Series Compensator (PWMSC, as new FACTS controller, for damping of low frequency oscillations. The PWMSC operates as a means of continuous control of the degree of series compensation through the variation of the duty cycle of a train of fixed frequency-pulses. The methodology is tested on the sample single machine power system including PWMSC controller by performing computer simulations for small and large distributions. MATLAB/ Simulink software package was used for the simulations.

  16. High performance predictive current control of a three phase VSI: An ...

    Indian Academy of Sciences (India)

    ... current control of a three phase VSI: An experimental assessment ... Voltage source inverter; two level inverter; predictive current control; weighting factor ... Conventionally, for reference current tracking control in a two level VSI, the objective ...

  17. Particle-in-cell simulations of electron beam control using an inductive current divider

    Energy Technology Data Exchange (ETDEWEB)

    Swanekamp, S. B.; Angus, J. R.; Cooperstein, G.; Ottinger, P. F.; Richardson, A. S.; Schumer, J. W.; Weber, B. V. [Plasma Physics Division, Naval Research Laboratory, Washington, District of Columbia 20375 (United States)

    2015-11-15

    Kinetic, time-dependent, electromagnetic, particle-in-cell simulations of the inductive current divider are presented. The inductive current divider is a passive method for controlling the trajectory of an intense, hollow electron beam using a vacuum structure that inductively splits the beam's return current. The current divider concept was proposed and studied theoretically in a previous publication [Swanekamp et al., Phys. Plasmas 22, 023107 (2015)]. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}) with the injected beam current given by I{sub b} = I{sub 1} + I{sub 2}. The simulations are in agreement with the theory which predicts that the total force on the beam trajectory is proportional to (I{sub 2}−I{sub 1}) and the force on the beam envelope is proportional to I{sub b}. Independent control over both the current density and the beam angle at the target is possible by choosing the appropriate current-divider geometry. The root-mean-square (RMS) beam emittance (ε{sub RMS}) varies as the beam propagates through the current divider to the target. For applications where control of the beam trajectory is desired and the current density at the target is similar to the current density at the entrance foil, there is a modest 20% increase in ε{sub RMS} at the target. For other applications where the beam is pinched to a current density ∼5 times larger at the target, ε{sub RMS} is 2–3 times larger at the target.

  18. Adaptive Hysteresis Band Current Control (AHB) with PLL of Grid Side Converter-Based Wind Power Generation System

    DEFF Research Database (Denmark)

    Guo, Yougui; Zeng, Ping; Li, Lijuan

    2011-01-01

    Adaptive hysteresis band current control(AHB CC) is used to control the three-phase grid currents by means of grid side converter in wind power generation system in this paper. AHB has reached the good purpose with PLL (Lock phase loop). First the mathematical models of each part are given......, transformer and grid, and control parts, etc. The simulation results have verified that the control strategy is feasible to fit for control of gird currents, active power, reactive power and DC-link voltage in wind power generation system....

  19. Architecture and control of a high current ion implanter system

    International Nuclear Information System (INIS)

    Bayer, E.H.; Paul, L.F.; Kranik, J.R.

    1979-01-01

    The design of an ion implant system for use in production requires that special attention be given to areas of design which normally are not emphasized on research or development type ion implanters. Manually operated, local controls are replaced by remote controls, automatic sequencing, and digital displays. For ease of maintenance and replication the individual components are designed as simply as possible and are contained in modules of separate identities, joined only by the beam line and electrical interconnections. A production environment also imposes requirements for the control of contamination and maintainability of clean room integrity. For that reason the major portion of the hardware is separated from the clean operator area and is housed in a maintenance core area. The controls of a production system should also be such that relatively unskilled technicians are able to operate the system with optimum repeatability and minimum operator intervention. An extensive interlock system is required. Most important, for use in production the ion implant system has to have a relatively high rate of throughput. Since the rate of throughput at a given dose is a function of beam current, pumpdown time and wafer handling capacity, design of components affecting these parameters has been optimized. Details of the system are given. (U.K.)

  20. Active flow control on a NACA 23012 airfoil model by means of magnetohydrodynamic plasma actuator

    International Nuclear Information System (INIS)

    Kazanskiy, P N; Moralev, I A; Bityurin, V A; Efimov, A V

    2016-01-01

    The paper is devoted to the study of high speed flow control around the airfoil by means of the Lorentz force. The latter is formed by creating the pulsed arc filament, moving in the magnetic field along the upper airfoil surface. The research was performed for the NACA23012 airfoil model at flow velocities up to 60 m/s (134 mph). The dynamic measurement of the aerodynamic forces on the airfoil was made. Changes up to 5% in an average value of lift and pitching moment were obtained at pulse repetition frequency up to 13 Hz and average discharge power less than 200 W. The amplitude of lift force oscillation was obtained as high as 10%, with the integration time of the balance 30 ms. The dynamic flow visualization of an airfoil model after a single discharge ignition was performed. It is shown that interaction of the main flow with the arc-induced disturbance leads to the dramatic changes in the flow structure. It was shown that the upstream movement of the arc channel (I = 40-700 A) leads to the local flow separation and simultaneously to the formation of a high pressure region above the model surface. Current paper presents investigation of previous work. (paper)

  1. Robust quasi NID current and flux control of an induction motor for position control

    NARCIS (Netherlands)

    van Duijnhoven, M.; Blachuta, M.J.

    1999-01-01

    In the paper, a new control design method called Dynamic Contraction method is applied to the flux and quadrature current robust control of an induction motor operated using the field orientation principle. The resulting input-output decoupled and linearized drive is then used for time-optimal

  2. A STUDY ABOUT CELL ACTIVITY ON ANODIZED Ti-6Al-4V BY MEANS OF PULSED CURRENT

    Directory of Open Access Journals (Sweden)

    LUANA M. R. VASCONCELLOS

    2017-05-01

    Full Text Available Titanium and some of its alloys exhibit excellent anti-corrosive and biocompatibility properties due to rapid formation of a passive film on their surfaces when exposed to the atmosphere. However, such materials presentpoor osteoindutive properties. Surfaces modified via anodization are being proposed in this study to promote a chemical interaction between implants and bone cells. For this purpose, samples in Ti-6Al-4V alloy discs were anodized in a phosphoric acid solution using pulsed current for being applied in orthopaedic implants. The pulsed current is based on duty cycle (DC, which was supplied by a square wave pulse rectifier at 100 Hz and maximum tension of 30 V. A scanning electron microscope was used to obtain images of the anodized surfaces, thus revealing the presence of uniformly distributed pores over the entire surface, measuring approximately 2 m in diameter. Osteogenic cells grown on the surface of the control and anodized samples were assayed for cytotoxicity and mineralized matrix formation. The anodized surfaces presented a higher rate of viable cells after 10 days, as well as a higher amount of nodules (p = 0.05. In conclusion, these results suggest that the nanotopography promoted by anodization using pulsed current induces beneficial modulatory effects on osteoblastic cells.

  3. Optimal control of LQG problem with an explicit trade-off between mean and variance

    Science.gov (United States)

    Qian, Fucai; Xie, Guo; Liu, Ding; Xie, Wenfang

    2011-12-01

    For discrete-time linear-quadratic Gaussian (LQG) control problems, a utility function on the expectation and the variance of the conventional performance index is considered. The utility function is viewed as an overall objective of the system and can perform the optimal trade-off between the mean and the variance of performance index. The nonlinear utility function is first converted into an auxiliary parameters optimisation problem about the expectation and the variance. Then an optimal closed-loop feedback controller for the nonseparable mean-variance minimisation problem is designed by nonlinear mathematical programming. Finally, simulation results are given to verify the algorithm's effectiveness obtained in this article.

  4. Zero-Axis Virtual Synchronous Coordinate Based Current Control Strategy for Grid-Connected Inverter

    Directory of Open Access Journals (Sweden)

    Longyue Yang

    2018-05-01

    Full Text Available Unbalanced power has a great influence on the safe and stable operation of the distribution network system. The static power compensator, which is essentially a grid-connected inverter, is an effective solution to the three-phase power imbalance problem. In order to solve the tracking error problem of zero-sequence AC current signals, a novel control strategy based on zero-axis virtual synchronous coordinates is proposed in this paper. By configuring the operation of filter transmission matrices, a specific orthogonal signal is obtained for zero-axis reconstruction. In addition, a controller design scheme based on this method is proposed. Compared with the traditional zero-axis direct control, this control strategy is equivalent to adding a frequency tuning module by the orthogonal signal generator. The control gain of an open loop system can be equivalently promoted through linear transformation. With its clear mathematical meaning, zero- sequence current control can be controlled with only a first-order linear controller. Through reasonable parameter design, zero steady-state error, fast response and strong stability can be achieved. Finally, the performance of the proposed control strategy is verified by both simulations and experiments.

  5. An on-line modified least-mean-square algorithm for training neurofuzzy controllers.

    Science.gov (United States)

    Tan, Woei Wan

    2007-04-01

    The problem hindering the use of data-driven modelling methods for training controllers on-line is the lack of control over the amount by which the plant is excited. As the operating schedule determines the information available on-line, the knowledge of the process may degrade if the setpoint remains constant for an extended period. This paper proposes an identification algorithm that alleviates "learning interference" by incorporating fuzzy theory into the normalized least-mean-square update rule. The ability of the proposed methodology to achieve faster learning is examined by employing the algorithm to train a neurofuzzy feedforward controller for controlling a liquid level process. Since the proposed identification strategy has similarities with the normalized least-mean-square update rule and the recursive least-square estimator, the on-line learning rates of these algorithms are also compared.

  6. A Control Method of Current Type Matrix Converter for Plasma Control Coil Power Supply

    International Nuclear Information System (INIS)

    Shimada, K.; Matsukawa, M.; Kurihara, K.; Jun-ichi Itoh

    2006-01-01

    In exploration to a tokamak fusion reactor, the control of plasma instabilities of high β plasma such as neoclassical tearing mode (NTM), resistive wall mode (RWM) etc., is the key issue for steady-state sustainment. One of the proposed methods to avoid suppressing RWM is that AC current having a phase to work for reduction the RWM growth is generated in a coil (sector coil) equipped spirally on the plasma vacuum vessel. To stabilize RWM, precise and fast real-time feedback control of magnetic field with proper amplitude and frequency is necessary. This implies that an appropriate power supply dedicated for such an application is expected to be developed. A matrix converter as one of power supply candidates for this purpose could provide a solution The matrix converter, categorized in an AC/AC direct converter composed of nine bi-directional current switches, has a great feature that a large energy storage element is unnecessary in comparison with a standard existing AC/AC indirect converter, which is composed of an AC/DC converter and a DC/AC inverter. It is also advantageous in cost and size of its applications. Fortunately, a voltage type matrix converter has come to be available at the market recently, while a current type matrix converter, which is advantageous for fast control of the large-inductance coil current, has been unavailable. On the background above mentioned, we proposed a new current type matrix converter and its control method applicable to a power supply with fast response for suppressing plasma instabilities. Since this converter is required with high accuracy control, the gate control method is adopted to three-phase switching method using middle phase to reduce voltage and current waveforms distortion. The control system is composed of VME-bus board with DSP (Digital Signal Processor) and FPGA (Field Programmable Gate Array) for high speed calculation and control. This paper describes the control method of a current type matrix converter

  7. Current trends in small vocabulary speech recognition for equipment control

    Science.gov (United States)

    Doukas, Nikolaos; Bardis, Nikolaos G.

    2017-09-01

    Speech recognition systems allow human - machine communication to acquire an intuitive nature that approaches the simplicity of inter - human communication. Small vocabulary speech recognition is a subset of the overall speech recognition problem, where only a small number of words need to be recognized. Speaker independent small vocabulary recognition can find significant applications in field equipment used by military personnel. Such equipment may typically be controlled by a small number of commands that need to be given quickly and accurately, under conditions where delicate manual operations are difficult to achieve. This type of application could hence significantly benefit by the use of robust voice operated control components, as they would facilitate the interaction with their users and render it much more reliable in times of crisis. This paper presents current challenges involved in attaining efficient and robust small vocabulary speech recognition. These challenges concern feature selection, classification techniques, speaker diversity and noise effects. A state machine approach is presented that facilitates the voice guidance of different equipment in a variety of situations.

  8. Seizing Control: From Current Treatments to Optogenetic Interventions in Epilepsy.

    Science.gov (United States)

    Bui, Anh D; Alexander, Allyson; Soltesz, Ivan

    2015-12-23

    The unpredictability and severity of seizures contribute to the debilitating nature of epilepsy. These factors also render the condition particularly challenging to treat, as an ideal treatment would need to detect and halt the pathological bursts of hyperactivity without disrupting normal brain activity. Optogenetic techniques offer promising tools to study and perhaps eventually treat this episodic disorder by controlling specific brain circuits in epileptic animals with great temporal precision. Here, we briefly review the current treatment options for patients with epilepsy. We then describe the many ways optogenetics has allowed us to untangle the microcircuits involved in seizure activity, and how it has, in some cases, changed our perception of previous theories of seizure generation. Control of seizures with light is no longer a dream, and has been achieved in numerous different animal models of epilepsy. Beyond its application as a seizure suppressor, we highlight another facet of optogenetics in epilepsy, namely the ability to create "on-demand" seizures, as a tool to systematically probe the dynamics of networks during seizure initiation and propagation. Finally, we look into the future to discuss the possibilities and challenges of translating optogenetic techniques to clinical use. © The Author(s) 2015.

  9. Use of recent geoid models to estimate mean dynamic topography and geostrophic currents in South Atlantic and Brazil Malvinas confluence

    Directory of Open Access Journals (Sweden)

    Alexandre Bernardino Lopes

    2012-03-01

    Full Text Available The use of geoid models to estimate the Mean Dynamic Topography was stimulated with the launching of the GRACE satellite system, since its models present unprecedented precision and space-time resolution. In the present study, besides the DNSC08 mean sea level model, the following geoid models were used with the objective of computing the MDTs: EGM96, EIGEN-5C and EGM2008. In the method adopted, geostrophic currents for the South Atlantic were computed based on the MDTs. In this study it was found that the degree and order of the geoid models affect the determination of TDM and currents directly. The presence of noise in the MDT requires the use of efficient filtering techniques, such as the filter based on Singular Spectrum Analysis, which presents significant advantages in relation to conventional filters. Geostrophic currents resulting from geoid models were compared with the HYCOM hydrodynamic numerical model. In conclusion, results show that MDTs and respective geostrophic currents calculated with EIGEN-5C and EGM2008 models are similar to the results of the numerical model, especially regarding the main large scale features such as boundary currents and the retroflection at the Brazil-Malvinas Confluence.A utilização de modelos geoidais na determinação da Topografia Dinâmica Média foi impulsionada com o lançamento dos satélites do sistema GRACE, já que seus modelos apresentam precisão e resolução espacial e temporal sem precedentes. No presente trabalho, além do modelo de nível médio do mar DNSC08, foram utilizados os seguintes modelos geoidais com o objetivo de calcular as TDMs: EGM96, EIGEN-5C e EGM2008. No método adotado, foram calculadas as respectivas correntes geostróficas para o Atlântico Sul a partir das TDMs. O grau e ordem dos modelos geoidais influenciam diretamente na determinação da TDM e correntes. Neste trabalho verificou-se que presença de ruídos da TDM requer a utilização de técnicas de filtragem

  10. Control systems for ITER diagnostics, heating and current drive

    Energy Technology Data Exchange (ETDEWEB)

    Simrock, Stefan, E-mail: stefan.simrock@iter.org

    2016-11-15

    The ITER Diagnostic, Heating and Current Drive systems might appear, on the face of it, to have very different control requirements. There are approximately 45 diagnostic systems, including magnetic sensors for plasma position and shape determination, imaging systems in the IR and visible, Thompson scattering for electron temperature and density, neutron detectors and collective scattering for alpha particle density and energy distribution. The H&CD systems encompass Electron Cyclotron Heating, using 24 1MW, 170 GHz gyrotrons and 5 steerable launchers to deliver 20 MW to the plasma, Ion Cyclotron Heating, using 8 3MW, 40–55 MHz sources and two multi-element launchers to deliver 20 MW to the plasma, and 2 Negative Ion Neutral Beam Injectors, each of which can deliver up to 16.5 MW of 1 MeV beams to the plasma. Although there are substantial differences in the needs for protection, when handling multi-MW heating systems, and in data throughput for many diagnostics, the formal processes needed to translate system requirements into Instrumentation and Control are identical. Due to the distributed procurement of ITER sub-systems and the need to integrate as painlessly as possible to CODAC, the formal processes, together with a substantial degree of standardization, are even more than usually essential. Starting from the technical, safety and protection, integration and operation requirements, a loop of functional analysis and signal listing is used to generate the controller configuration and the conceptual architecture. These elements in their turn lead to the physical and software design. The paper will describe the formal processes of control system design and the methods used by the ITER project to achieve the standardization of systems engineering practices. These have been applied to several use-cases covering all operation relevant phases such as plasma operation, maintenance, testing and conditioning. There are a number of running contracts that are developing

  11. Availability Control for Means of Transport in Decisive Semi-Markov Models of Exploitation Process

    Science.gov (United States)

    Migawa, Klaudiusz

    2012-12-01

    The issues presented in this research paper refer to problems connected with the control process for exploitation implemented in the complex systems of exploitation for technical objects. The article presents the description of the method concerning the control availability for technical objects (means of transport) on the basis of the mathematical model of the exploitation process with the implementation of the decisive processes by semi-Markov. The presented method means focused on the preparing the decisive for the exploitation process for technical objects (semi-Markov model) and after that specifying the best control strategy (optimal strategy) from among possible decisive variants in accordance with the approved criterion (criteria) of the activity evaluation of the system of exploitation for technical objects. In the presented method specifying the optimal strategy for control availability in the technical objects means a choice of a sequence of control decisions made in individual states of modelled exploitation process for which the function being a criterion of evaluation reaches the extreme value. In order to choose the optimal control strategy the implementation of the genetic algorithm was chosen. The opinions were presented on the example of the exploitation process of the means of transport implemented in the real system of the bus municipal transport. The model of the exploitation process for the means of transports was prepared on the basis of the results implemented in the real transport system. The mathematical model of the exploitation process was built taking into consideration the fact that the model of the process constitutes the homogenous semi-Markov process.

  12. Optimization of control parameters of a hot cold controller by means of Simplex type methods

    Science.gov (United States)

    Porte, C.; Caron-Poussin, M.; Carot, S.; Couriol, C.; Moreno, M. Martin; Delacroix, A.

    1997-01-01

    This paper describes a hot/cold controller for regulating crystallization operations. The system was identified with a common method (the Broida method) and the parameters were obtained by the Ziegler-Nichols method. The paper shows that this empirical method will only allow a qualitative approach to regulation and that, in some instances, the parameters obtained are unreliable and therefore cannot be used to cancel variations between the set point and the actual values. Optimization methods were used to determine the regulation parameters and solve this identcation problem. It was found that the weighted centroid method was the best one. PMID:18924791

  13. BIOLOGICAL CONTROL - AS A MEANS TO CONTROL INSECT PESTS IN AZERBAIJAN

    Directory of Open Access Journals (Sweden)

    Z. M. Mamedov

    2013-01-01

    Full Text Available Two hundreds and twenty species parasites and predators of pests of various agricultures are revealed in Azerbaijan. The complex of entomophages of certain pests of agricultures is studied: 48 species of parasites and predators of Chloridea obsoleta 21 species of entomophages of Pectinophora malvella Hb., over 160 species of entomophages of pests of ozehards and vegetables, 34 species of entomophages of pests of forests. The hundreds species of entomophages and some entomophogenous microbes and antagonists are revealed. Biology and ecology of over 60 species of entomophages and useful microorganisims which are prospective as biological control agents are studied.

  14. Development and Validation in Air Traffic Control by Means of Real-Time Simulations

    Directory of Open Access Journals (Sweden)

    Stephan Herr

    2009-02-01

    Full Text Available The airspace in Central Europe is already one of the busiest airspaces in the world and the forecasts predict further traffic increases. The current air transport system is reaching its capacity limits, not only at airports but also in parts of the en-route area. This is mainly due to the workload constraints of air traffic controllers. In the past, many technical system functionalities were developed with the aim of reducing controller workload and thus enabling the safe handling of the predicted traffic growth. But these new functionalities alone will not provide adequate relief to air traffic controllers. Their working procedures and the airspace structure will have to be adapted accordingly. In order to obtain real operational benefits, these technical innovations must be integrated into an overall concept which – in addition to the above-mentioned factors – also takes account of ergonomic aspects and human-machine interfaces. When developing such an overall concept, additional evaluation and validation measures are indispensable to ensure that the desired operational benefits are achieved. This is why DFS has for many years used fast- and real-time simulations to assess and optimise any changes to be made to the air traffic control system. The working methods of DFS in this context are in keeping with the European Operational Concept Validation Methodology of 2007, in short E-OCVM. This paper outlines the development and validation activities of DFS using the MSP D/L project as an example. The project deals with the introduction of the new role of air traffic controllers as multi-sector planners (MSP and new system functionalities, such as air/ground data link (D/L. The project included the development of an operational concept for using the new functionalities as well as for defining working procedures and the airspace structure. This concept was subsequently evaluated by means of a fast-time simulation and two real-time simulations

  15. Non-destructive methods and means for quality control of structural products

    International Nuclear Information System (INIS)

    Dmitriev, V.V.

    1989-01-01

    Progressive non-destructive methods (acoustic, magnetic, radiation with liquid penetrants) and means of control of structural product quality, allowing to determine the state of products and structures not only immediately after their production but directly at the erected or reconstructed objects are described

  16. Dynamical control of quantum systems in the context of mean ergodic theorems

    International Nuclear Information System (INIS)

    Bernád, J Z

    2017-01-01

    Equidistant and non-equidistant single pulse ‘bang–bang’ dynamical controls are investigated in the context of mean ergodic theorems. We show the requirements in which the limit of infinite pulse control for both the equidistant and the non-equidistant dynamical control converges to the same unitary evolution. It is demonstrated that the generator of this evolution can be obtained by projecting the generator of the free evolution onto the commutant of the unitary operator representing the pulse. Inequalities are derived to prove this statement and in the case of non-equidistant approach these inequalities are optimised as a function of the time intervals. (paper)

  17. Balanced Current Control Strategy for Current Source Rectifier Stage of Indirect Matrix Converter under Unbalanced Grid Voltage Conditions

    Directory of Open Access Journals (Sweden)

    Yeongsu Bak

    2016-12-01

    Full Text Available This paper proposes a balanced current control strategy for the current source rectifier (CSR stage of an indirect matrix converter (IMC under unbalanced grid voltage conditions. If the three-phase grid connected to the voltage source inverter (VSI of the IMC has unbalanced voltage conditions, it affects the currents of the CSR stage and VSI stage, and the currents are distorted. Above all, the distorted currents of the CSR stage cause instability in the overall system, which can affect the life span of the system. Therefore, in this paper, a control strategy for balanced currents in the CSR stage is proposed. To achieve balanced currents in the CSR stage, the VSI stage should receive DC power without ripple components from the CSR stage. This is implemented by controlling the currents in the VSI stage. Therefore, the proposed control strategy decouples the positive and negative phase-sequence components existing in the unbalanced voltages and currents of the VSI stage. Using the proposed control strategy under unbalanced grid voltage conditions, the stability and life span of the overall system can be improved. The effectiveness of the proposed control strategy is verified by simulation and experimental results.

  18. Cerebellar transcranial direct current stimulation improves adaptive postural control.

    Science.gov (United States)

    Poortvliet, Peter; Hsieh, Billie; Cresswell, Andrew; Au, Jacky; Meinzer, Marcus

    2018-01-01

    Rehabilitation interventions contribute to recovery of impaired postural control, but it remains a priority to optimize their effectiveness. A promising strategy may involve transcranial direct current stimulation (tDCS) of brain areas involved in fine-tuning of motor adaptation. This study explored the effects of cerebellar tDCS (ctDCS) on postural recovery from disturbance by Achilles tendon vibration. Twenty-eight healthy volunteers participated in this sham-ctDCS controlled study. Standing blindfolded on a force platform, four trials were completed: 60 s quiet standing followed by 20 min active (anodal-tDCS, 1 mA, 20 min, N = 14) or sham-ctDCS (40 s, N = 14) tDCS; three quiet standing trials with 15 s of Achilles tendon vibration and 25 s of postural recovery. Postural steadiness was quantified as displacement, standard deviation and path derived from the center of pressure (COP). Baseline demographics and quiet standing postural steadiness, and backwards displacement during vibration were comparable between groups. However, active-tDCS significantly improved postural steadiness during vibration and reduced forward displacement and variability in COP derivatives during recovery. We demonstrate that ctDCS results in short-term improvement of postural adaptation in healthy individuals. Future studies need to investigate if multisession ctDCS combined with training or rehabilitation interventions can induce prolonged improvement of postural balance. Copyright © 2017 International Federation of Clinical Neurophysiology. Published by Elsevier B.V. All rights reserved.

  19. Risk-sensitivity and the mean-variance trade-off: decision making in sensorimotor control.

    Science.gov (United States)

    Nagengast, Arne J; Braun, Daniel A; Wolpert, Daniel M

    2011-08-07

    Numerous psychophysical studies suggest that the sensorimotor system chooses actions that optimize the average cost associated with a movement. Recently, however, violations of this hypothesis have been reported in line with economic theories of decision-making that not only consider the mean payoff, but are also sensitive to risk, that is the variability of the payoff. Here, we examine the hypothesis that risk-sensitivity in sensorimotor control arises as a mean-variance trade-off in movement costs. We designed a motor task in which participants could choose between a sure motor action that resulted in a fixed amount of effort and a risky motor action that resulted in a variable amount of effort that could be either lower or higher than the fixed effort. By changing the mean effort of the risky action while experimentally fixing its variance, we determined indifference points at which participants chose equiprobably between the sure, fixed amount of effort option and the risky, variable effort option. Depending on whether participants accepted a variable effort with a mean that was higher, lower or equal to the fixed effort, they could be classified as risk-seeking, risk-averse or risk-neutral. Most subjects were risk-sensitive in our task consistent with a mean-variance trade-off in effort, thereby, underlining the importance of risk-sensitivity in computational models of sensorimotor control.

  20. Current profile control experiments in EXTRAP T2R

    Science.gov (United States)

    Brunsell, P.; Cecconello, M.; Drake, J.; Franz, P.; Malmberg, J. A.; Marrelli, L.; Martin, P.; Spizzo, G.

    2002-11-01

    EXTRAP T2R is a high aspect ratio (R=1.24 m, a = 0.183 m) reversed-field pinch device, characterised by a double, thin shell system. The simultaneous presence of many m=1, |n| > 11 tearing modes is responsible for a magnetic field turbulence, which is believed to produce the rather high energy and particle transport that is observed in this type of magnetic configuration. In this paper first results from current profile control experiments (PPCD) in a thin shell device are shown. When an edge poloidal electric field is transiently applied, an increase of the electron temperature and of the electron density is seen, which is consistent with an increase of the thermal content of the plasma. At the same time, the soft x-ray emission, measured with a newly installed miniaturised camera, shows a peaking of the profile in the core. Furthermore, the amplitudes of the m=1 tearing modes are reduced and and the rotation velocities increase during PPCD, which is also consistent with a reduction of magnetic turbulence and a heating of the plasma

  1. Data in support of environmental controls on the characteristics of mean number of forest fires and mean forest area burned (1987–2007 in China

    Directory of Open Access Journals (Sweden)

    Yu Chang

    2015-09-01

    Full Text Available Fire frequency and size are two important parameters describing fire characteristics. Exploring the spatial variation of fire characteristics and understanding the environmental controls are indispensable to fire prediction and sustainable forest landscape management. To illustrate the spatial variation of forest fire characteristics over China and to quantitatively determine the relative contribution of each of the environmental controls to this variation, forest fire characteristic data (mean number of forest fires and mean burned forest area and environmental data (climate, land use, vegetation type and topography at provincial level were derived. These data sets can potentially serve as a foundation for future studies relating to fire risk assessment, carbon emission by forest fires, and the impact of climate change on fire characteristics. This data article contains data related to the research article entitled “Environmental controls on the characteristics of mean number of forest fires and mean forest area burned (1987–2007 in China” by chang et al. [1].

  2. A Self-Oscillating Control Scheme for a Boost Converter Providing a Controlled Output Current

    DEFF Research Database (Denmark)

    Knott, Arnold; Pfaffinger, Gerhard R.; Andersen, Michael A. E.

    2011-01-01

    Most switched mode power supplies provide a regulated voltage at their output. However, there are applications requiring a controlled current. Among others are battery chargers, test equipment for converters driven by solar cells, and LED drivers. This paper describes a dc–dc power converter real...

  3. Mitigation of Grid Current Distortion for LCL-Filtered Voltage Source Inverter with Inverter Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    LCL filters feature low inductance; thus, the injected grid current from an LCL-filtered Voltage Source Inverter (VSI) can be easily distorted by grid voltage harmonics. This problem is especially tough for the control system with Inverter-side Current Feedback (ICF), since the grid current...... harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...

  4. Hippocampus age-related microstructural changes in schizophrenia: a case-control mean diffusivity study.

    Science.gov (United States)

    Chiapponi, Chiara; Piras, Fabrizio; Fagioli, Sabrina; Girardi, Paolo; Caltagirone, Carlo; Spalletta, Gianfranco

    2014-08-01

    Macrostructural-volumetric abnormalities of the hippocampus have been described in schizophrenia. Here, we characterized age-related changes of hippocampal mean diffusivity as an index of microstructural damage by carrying out a neuroimaging study in 85 patients with a DSM-IV-TR diagnosis of schizophrenia and 85 age- and gender-matched healthy controls. We performed analyses of covariance, with diagnosis as fixed factor, mean diffusivity as dependent variable and age as covariate. Patients showed an early increase in mean diffusivity in the right and left hippocampus that increased with age. Thus, microstructural hippocampal changes associated with schizophrenia cannot be confined to a specific time window. Copyright © 2014 Elsevier B.V. All rights reserved.

  5. Steam generator degradation: Current mitigation strategies for controlling corrosion

    International Nuclear Information System (INIS)

    Millett, P.

    1997-01-01

    Steam Generator degradation has caused substantial losses of power generation, resulted in large repair and maintenance costs, and contributed to significant personnel radiation exposures in Pressurized Water Reactors (PWRs) operating throughout the world. EPRI has just published the revised Steam Generator Reference Book, which reviews all of the major forms of SG degradation. This paper discusses the types of SG degradation that have been experienced with emphasis on the mitigation strategies that have been developed and implemented in the field. SG degradation is presented from a world wide perspective as all countries operating PWRs have been effected to one degree or another. The paper is written from a US. perspective where the utility industry is currently undergoing tremendous change as a result of deregulation of the electricity marketplace. Competitive pressures are causing utilities to strive to reduce Operations and Maintenance (O ampersand M) and capital costs. SG corrosion is a major contributor to the O ampersand M costs of PWR plants, and therefore US utilities are evaluating and implementing the most cost effective solutions to their corrosion problems. Mitigation strategies developed over the past few years reflect a trend towards plant specific solutions to SG corrosion problems. Since SG degradation is in most cases an economic problem and not a safety problem, utilities can focus their mitigation strategies on their unique financial situation. Accordingly, the focus of R ampersand D has shifted from the development of more expensive, prescriptive solutions (e.g. reduced impurity limits) to corrosion problems to providing the utilities with a number of cost effective mitigation options (e.g. molar ratio control, boric acid treatment)

  6. LED Current Balance Using a Variable Voltage Regulator with Low Dropout vDS Control

    Directory of Open Access Journals (Sweden)

    Hung-I Hsieh

    2017-02-01

    Full Text Available A cost-effective light-emitting diode (LED current balance strategy using a variable voltage regulator (VVR with low dropout vDS control is proposed. This can regulate the multiple metal-oxide-semiconductor field-effect transistors (MOSFETs of the linear current regulators (LCR, maintaining low dropout vDS on the flat vGS-characteristic curves and making all drain currents almost the same. Simple group LCRs respectively loaded with a string LED are employed to implement the theme. The voltage VVdc from a VVR is synthesized by a string LED voltage NvD, source voltage vR, and a specified low dropout vDS = VQ. The VVdc updates instantly, through the control loop of the master LCR, which means that all slave MOSFETs have almost the same biases on their flat vGS-characteristic curves. This leads to all of the string LED currents being equal to each other, producing an almost even luminance. An experimental setup with microchip control is built to verify the estimations. Experimental results show that the luminance of all of the string LEDs are almost equal to one another, with a maximum deviation below 1% during a wide dimming range, while keeping all vDS of the MOSFETs at a low dropout voltage, as expected.

  7. [Predictors of mean blood glucose control and its variability in diabetic hospitalized patients].

    Science.gov (United States)

    Sáenz-Abad, Daniel; Gimeno-Orna, José Antonio; Sierra-Bergua, Beatriz; Pérez-Calvo, Juan Ignacio

    2015-01-01

    This study was intended to assess the effectiveness and predictors factors of inpatient blood glucose control in diabetic patients admitted to medical departments. A retrospective, analytical cohort study was conducted on patients discharged from internal medicine with a diagnosis related to diabetes. Variables collected included demographic characteristics, clinical data and laboratory parameters related to blood glucose control (HbA1c, basal plasma glucose, point-of-care capillary glucose). The cumulative probability of receiving scheduled insulin regimens was evaluated using Kaplan-Meier analysis. Multivariate regression models were used to select predictors of mean inpatient glucose (MHG) and glucose variability (standard deviation [GV]). The study sample consisted of 228 patients (mean age 78.4 (SD 10.1) years, 51% women). Of these, 96 patients (42.1%) were treated with sliding-scale regular insulin only. Median time to start of scheduled insulin therapy was 4 (95% CI, 2-6) days. Blood glucose control measures were: MIG 181.4 (SD 41.7) mg/dL, GV 56.3 (SD 22.6). The best model to predict MIG (R(2): .376; P<.0001) included HbA1c (b=4.96; P=.011), baseline plasma glucose (b=.056; P=.084), mean capillary blood glucose in the first 24hours (b=.154; P<.0001), home treatment (versus oral agents) with basal insulin only (b=13.1; P=.016) or more complex (pre-mixed insulin or basal-bolus) regimens (b=19.1; P=.004), corticoid therapy (b=14.9; P=.002), and fasting on admission (b=10.4; P=.098). Predictors of inpatient blood glucose control which should be considered in the design of DM management protocols include home treatment, HbA1c, basal plasma glucose, mean blood glucose in the first 24hours, fasting, and corticoid therapy. Copyright © 2014 SEEN. Published by Elsevier España, S.L.U. All rights reserved.

  8. Performance Improvement of tilting-pad journal bearings by means of controllable lubrication

    DEFF Research Database (Denmark)

    Cerda, Alejandro; Santos, Ilmar

    2012-01-01

    Tilting-Pad Journal Bearings (TPJB) are commonly used on high-performance turbomachinery due to their excellent stability properties at high speed when compared to other designs for oil film bearings. Hence, efforts have been made to improve the accuracy for the available models for these mechani...... is used to show the benefits of applying a controllable lubrication regime, by means of the modification of the thermal and dynamic behaviour of the bearing....

  9. Cross Voltage Control with Inner Hysteresis Current Control for Multi-output Boost Converter

    DEFF Research Database (Denmark)

    Nami, Alireza; Zare, Firuz; Blaabjerg, Frede

    2009-01-01

    Multi-output boost (MOB) converter is a novel DC-DC converter unlike the regular boost converter, has the ability to share its total output voltage and to have different series output voltage from a given duty cycle for low and high power applications. In this paper, discrete voltage control...... with inner hysteresis current control loop has been proposed to keep the simplicity of the control law for the double-output MOB converter, which can be implemented by a combination of analogue and logical ICs or simple microcontroller to constrain the output voltages of MOB converter at their reference...... voltages against variation in load or input voltage. The salient features of the proposed control strategy are simplicity of implementation and ease to extend to multiple outputs in the MOB converter. Simulation and experimental results are presented to show the validity of control strategy....

  10. Stable Control of Firing Rate Mean and Variance by Dual Homeostatic Mechanisms.

    Science.gov (United States)

    Cannon, Jonathan; Miller, Paul

    2017-12-01

    Homeostatic processes that provide negative feedback to regulate neuronal firing rates are essential for normal brain function. Indeed, multiple parameters of individual neurons, including the scale of afferent synapse strengths and the densities of specific ion channels, have been observed to change on homeostatic time scales to oppose the effects of chronic changes in synaptic input. This raises the question of whether these processes are controlled by a single slow feedback variable or multiple slow variables. A single homeostatic process providing negative feedback to a neuron's firing rate naturally maintains a stable homeostatic equilibrium with a characteristic mean firing rate; but the conditions under which multiple slow feedbacks produce a stable homeostatic equilibrium have not yet been explored. Here we study a highly general model of homeostatic firing rate control in which two slow variables provide negative feedback to drive a firing rate toward two different target rates. Using dynamical systems techniques, we show that such a control system can be used to stably maintain a neuron's characteristic firing rate mean and variance in the face of perturbations, and we derive conditions under which this happens. We also derive expressions that clarify the relationship between the homeostatic firing rate targets and the resulting stable firing rate mean and variance. We provide specific examples of neuronal systems that can be effectively regulated by dual homeostasis. One of these examples is a recurrent excitatory network, which a dual feedback system can robustly tune to serve as an integrator.

  11. A Short-Current Control Method for Constant Frequency Current-Fed Wireless Power Transfer Systems

    Directory of Open Access Journals (Sweden)

    Yanling Li

    2017-04-01

    Full Text Available Frequency drift is a serious problem in Current-Fed Wireless Power Transfer (WPT systems. When the operating frequency is drifting from the inherent Zero Voltage Switching (ZVS frequency of resonant network, large short currents will appear and damage the switches. In this paper, an inductance-dampening method is proposed to inhibit short currents and achieve constant-frequency operation. By adding a small auxiliary series inductance in the primary resonant network, short currents are greatly attenuated to a safe level. The operation principle and steady-state analysis of the system are provided. An overlapping time self-regulating circuit is designed to guarantee ZVS running. The range of auxiliary inductances is discussed and its critical value is calculated exactly. The design methodology is described and a design example is presented. Finally, a prototype is built and the experimental results verify the proposed method.

  12. Automatic analysis of signals during Eddy currents controls

    International Nuclear Information System (INIS)

    Chiron, D.

    1983-06-01

    A method and the corresponding instrument have been developed for automatic analysis of Eddy currents testing signals. This apparatus enables at the same time the analysis, every 2 milliseconds, of two signals at two different frequencies. It can be used either on line with an Eddy Current testing instrument or with a magnetic tape recorder [fr

  13. A Technique to Estimate the Equivalent Loss Resistance of Grid-Tied Converters for Current Control Analysis and Design

    DEFF Research Database (Denmark)

    Vidal, Ana; Yepes, Alejandro G.; Fernandez, Francisco Daniel Freijedo

    2015-01-01

    Rigorous analysis and design of the current control loop in voltage source converters (VSCs) requires an accurate modeling. The loop behavior can be significantly influenced by the VSC working conditions. To consider such effect, converter losses should be included in the model, which can be done...... by means of an equivalent series resistance. This paper proposes a method to identify the VSC equivalent loss resistance for the proper tuning of the current control loop. It is based on analysis of the closed-loop transient response provided by a synchronous proportional-integral current controller......, according to the internal model principle. The method gives a set of loss resistance values linked to working conditions, which can be used to improve the tuning of the current controllers, either by online adaptation of the controller gains or by open-loop adaptive adjustment of them according to prestored...

  14. A Comparative Study of Voltage, Peak Current and Dual Current Mode Control Methods for Noninverting Buck-Boost Converter

    Directory of Open Access Journals (Sweden)

    M. Č. Bošković

    2016-06-01

    Full Text Available This paper presents a comparison of voltage mode control (VMC and two current mode control (CMC methods of noninverting buck-boost converter. The converter control-to-output transfer function, line-to-output transfer function and the output impedance are obtained for all methods by averaging converter equations over one switching period and applying small-signal linearization. The obtained results are required for the design procedure of feedback compensator to keep a system stable and robust. A comparative study of VMC, peak current mode control (PCMC and dual-current mode control (DCMC is performed. Performance evaluation of the closed-loop system with obtained compensator between these methods is performed via numerical simulations.

  15. Identification and disruption of bacteria associated with sheep scab mites-novel means of control?

    Science.gov (United States)

    Hall, S A; Mack, K; Blackwell, A; Evans, K A

    2015-10-01

    Psoroptes ovis mites, which cause psoroptic mange (sheep scab), were investigated to identify potential bacterial targets for endosymbiont control of sheep scab. In addition, transmission of bacteria to the sheep skin was investigated through the characterisation of bacteria present in P. ovis faecal trails and on the fleece environment by internal transcribed spacer (ITS) sequencing. A diverse range of bacteria was identified in addition to a potential endosymbiont candidate, Comamonas sp, which was detected in P. ovis by both ITS PCR and endosymbiont-specific PCR. Disruption of these bacteria within P. ovis, through the use of antibiotics, was explored; with significant reduction in mean mite survival when administered antibiotic diets compared with controls (LR4 = 23.12, P bacteria associated with P. ovis should be further investigated for novel control. Copyright © 2015 Elsevier Inc. All rights reserved.

  16. A Modified Droop Control Method for Parallel-Connected Current Source Inverters

    DEFF Research Database (Denmark)

    Wei, Baoze; Guerrero, Josep M.; Quintero, Juan Carlos Vasquez

    2016-01-01

    In this paper, a novel control method was proposed for current source inverters under the grid-connected working mode. The control scheme is based on a modified droop control method, with an additional current reference signal that will be generated instead of the voltage reference. Hence......, there is only a current control loop with droop control in the whole control scheme without voltage control loop. So it is very suitable for grid-connected current source inverter which will simplify the design of the control scheme and combine the advantage of droop control. The parallel configuration...... is widely used to acquire high power demand, but the circulating current problem is a key issue that should be considered. In this paper, a simulation based on parallel current source inverters using the proposed control scheme is provided. Simulation results showed that a good circulating current...

  17. Fragmented Canopies Control the Regimes of Gravity Current Development

    Science.gov (United States)

    Barcelona, Aina; Serra, Teresa; Colomer, Jordi

    2018-03-01

    Coastal ecosystems (marine littoral regions, wetlands, and deltas) are regions of high biological productivity. However, they are also one of the world's most threatened ecosystems. Wetlands are characterized by aquatic vegetation adapted to high salinity levels and climatic variations. Wetland canopies buffer these hydrodynamic and atmospheric variations and help retain sediment by reducing current velocity during sea storms or runoff after periods of rain. This work focuses on the effect of the presence of a gap (i.e., nonvegetated zone) parallel to the direction of the main current has on the sedimentation and hydrodynamics of a gravity current. The study aims to (1) address the behavior of a gravity current in a vegetated region compared to one without vegetation (i.e., the gap), (2) determine the effect gap size has on how a gravity current evolves, and 3) determine the effect gap sizes have on the sedimentary rates from a gravity current. Laboratory experiments were carried out in a flume using four different sediment concentrations, four different canopy densities (884, 354, 177, and 0 plants·m-2) and three different gap widths (H/2, H, and 1.5H, where H is the height of the water). This work shows that a gravity current's evolution and its sedimentary rates depend on the fractional volume occupied by the vegetation. While current dynamics in experiments with wider gaps are similar to the nonvegetated case, for smaller gaps the dynamics are closer to the fully vegetated case. Nonetheless, the gravity current exhibits the same behavior in both the vegetated region and the gap.

  18. Dead Zone Oscillator Control for Communication-Free Synchronization of Paralleled, Three-Phase, Current-Controlled Inverters

    Science.gov (United States)

    2016-05-11

    Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab, USN UNITED STATES NAVAL ACADEMY...Three-Phase, Current-Controlled Inverters by Midshipman 1/C Spencer C. Shabshab United States Naval Academy Annapolis, Maryland...for Communication-Free Synchronization of Paralleled, 5a. CONTRACT NUMBER Three-Phase, Current-Controlled Inverters 5b. GRANT NUMBER 5c

  19. The mean first passage time in an energy-diffusion controlled regime with power-law distributions

    International Nuclear Information System (INIS)

    Zhou, Yanjun; Du, Jiulin

    2013-01-01

    Based on the mean first passage time (MFPT) theory, we derive an expression of the MFPT in an energy-diffusion controlled regime with a power-law distribution. We discuss the finite barrier effect (i.e. the thermal energy k B T is not small with respect to the potential barrier E b ) and compare it with Kramers’ infinite barrier result both in a power-law distribution and in a Maxwell–Boltzmann distribution. It is shown that the MFPT with a power-law distribution extends Kramers’ low-damping result to a relatively low barrier. We pay attention to the energy-diffusion controlled regime, which is of great interest in the context of Josephson junctions, and study how the power-law parameter κ affects the current distribution function in experiments with Josephson junctions. (paper)

  20. STRENGTHENING THE SUSTAINABILITY OF PUBLIC FINANCES BY MEANS OF FINANCIAL LAW FOCUSED ON THE CONTROL AND AUDIT EXERCISE

    Directory of Open Access Journals (Sweden)

    Ionel BOSTAN

    2016-02-01

    Full Text Available The activity to prevent embrittlement sustainability of public finances should manifest itself permanently, regardless of economic circumstances - national or European. This, more so as it was set by the Stability and Growth Pact (SGP, which introduces new rules on fiscal policy. Regulations and exercise adequate of financial control and public audit are intended to give certain guarantees on landing approach this topic (most on enhancing sustainability of public finances. Therefore, our approach aims to reveal some aspects of fiscal consolidation by means of financial law focused on exercise fiscal control and public audit. Our references aim the current regulatory of this important organization and functioning rule of law activities and results reported.

  1. Optimized design of resonant controller for stator current harmonic compensation in DFIG wind turbine systems

    DEFF Research Database (Denmark)

    Liu, Changjin; Chen, Wenjie; Blaabjerg, Frede

    2012-01-01

    This paper presents an analytical method to optimize the parameters of resonant controller which is used in a Doubly-Fed Induction Generator (DFIG). In the DFIG control system, the fundamental current loop is controlled by PI-controllers, and the stator harmonic current loop is controlled...

  2. ICRF current drive by using antenna phase control

    International Nuclear Information System (INIS)

    Kishimoto, Y.; Itoh, K.

    1987-01-01

    A global analysis of current drive in tokamaks by using waves in the ion cyclotron range of frequencies (ICRF), considering the entire antenna-plasma system, is presented. A phase shifted antenna array is used to inject toroidal momentum into the electrons. Within the context of quasi-linear theory, a Fokker-Planck calculation is combined with an ICRF wave propagation-absorption analysis which includes kinetic effects and realistic boundary conditions. The radial profile of the current induced by the mode converted ion Bernstein wave and by the magnetosonic fast wave is obtained, together with the global current drive efficiency (total induced current/total emitted power from the antennas) in the high density and temperature plasma regime. The phase dependence of the global efficiency is investigated by changing the launching conditions such as the total antenna number and the antenna spacing. In medium size tokamaks, the electron power absorption and the associated driven current are found to be affected considerably by the plasma cavity resonance. It is also found that the global efficiency is sensitive to the antenna spacing. When the antenna spacing is increased, the global efficiency is reduced by counter current generation. (author)

  3. The need to control for regression to the mean in social psychology studies

    Directory of Open Access Journals (Sweden)

    Rongjun eYu

    2015-01-01

    Full Text Available It is common in repeated measurements for extreme values at the first measurement to approach the mean at the subsequent measurement, a phenomenon called regression to the mean (RTM. If RTM is not fully controlled, it will lead to erroneous conclusions. The wide use of repeated measurements in social psychology creates a risk that an RTM effect will influence results. However, insufficient attention is paid to RTM in most social psychological research. Notable cases include studies on the phenomena of social conformity and unrealistic optimism. In Study 1, 13 university students rated and re-rated the facial attractiveness of a series of female faces as a test of the social conformity effect. In Study 2, 15 university students estimated and re-estimated their risk of experiencing a series of adverse life events as a test of the unrealistic optimism effect. Although these studies used methodologies similar to those used in earlier research, the social conformity and unrealistic optimism effects were no longer evident after controlling for RTM. Based on these findings we suggest several ways to control for the RTM effect in social psychology studies.

  4. On a mean field game optimal control approach modeling fast exit scenarios in human crowds

    KAUST Repository

    Burger, Martin; Di Francesco, Marco; Markowich, Peter A.; Wolfram, Marie Therese

    2013-01-01

    The understanding of fast exit and evacuation situations in crowd motion research has received a lot of scientific interest in the last decades. Security issues in larger facilities, like shopping malls, sports centers, or festivals necessitate a better understanding of the major driving forces in crowd dynamics. In this paper we present an optimal control approach modeling fast exit scenarios in pedestrian crowds. The model is formulated in the framework of mean field games and based on a parabolic optimal control problem. We consider the case of a large human crowd trying to exit a room as fast as possible. The motion of every pedestrian is determined by minimizing a cost functional, which depends on his/her position and velocity, the overall density of people, and the time to exit. This microscopic setup leads in a mean-field formulation to a nonlinear macroscopic optimal control problem, which raises challenging questions for the analysis and numerical simulations.We discuss different aspects of the mathematical modeling and illustrate them with various computational results. ©2013 IEEE.

  5. On a mean field game optimal control approach modeling fast exit scenarios in human crowds

    KAUST Repository

    Burger, Martin

    2013-12-01

    The understanding of fast exit and evacuation situations in crowd motion research has received a lot of scientific interest in the last decades. Security issues in larger facilities, like shopping malls, sports centers, or festivals necessitate a better understanding of the major driving forces in crowd dynamics. In this paper we present an optimal control approach modeling fast exit scenarios in pedestrian crowds. The model is formulated in the framework of mean field games and based on a parabolic optimal control problem. We consider the case of a large human crowd trying to exit a room as fast as possible. The motion of every pedestrian is determined by minimizing a cost functional, which depends on his/her position and velocity, the overall density of people, and the time to exit. This microscopic setup leads in a mean-field formulation to a nonlinear macroscopic optimal control problem, which raises challenging questions for the analysis and numerical simulations.We discuss different aspects of the mathematical modeling and illustrate them with various computational results. ©2013 IEEE.

  6. Off-axis current drive and real-time control of current profile in JT-60U

    International Nuclear Information System (INIS)

    Suzuki, T.; Ide, S.; Oikawa, T.; Fujita, T.; Ishikawa, M.; Seki, M.; Matsunaga, G.; Hatae, T.; Naito, O.; Hamamatsu, K.; Sueoka, M.; Hosoyama, H.; Nakazato, M.

    2008-01-01

    Aiming at optimization of current profile in high-β plasmas for higher confinement and stability, a real-time control system of the minimum of the safety factor (q min ) using the off-axis current drive has been developed. The off-axis current drive can raise the safety factor in the centre and help to avoid instability that limits the performance of the plasma. The system controls the injection power of lower-hybrid waves, and hence its off-axis driven current in order to control q min . The real-time control of q min is demonstrated in a high-β plasma, where q min follows the temporally changing reference q min,ref from 1.3 to 1.7. Applying the control to another high-β discharge (β N = 1.7, β p = 1.5) with m/n = 2/1 neo-classical tearing mode (NTM), q min was raised above 2 and the NTM was suppressed. The stored energy increased by 16% with the NTM suppressed, since the resonant rational surface was eliminated. For the future use for current profile control, current density profile for off-axis neutral beam current drive (NBCD) is for the first time measured, using the motional Stark effect diagnostic. Spatially localized NBCD profile was clearly observed at the normalized minor radius ρ of about 0.6-0.8. The location was also confirmed by multi-chordal neutron emission profile measurement. The total amount of the measured beam driven current was consistent with the theoretical calculation using the ACCOME code. The CD location in the calculation was inward shifted than the measurement

  7. Thoracic radiotherapy and breath control: current prospects; Radiotherapie thoracique et controle de la respiration: perspectives actuelles

    Energy Technology Data Exchange (ETDEWEB)

    Reboul, F.; Mineur, L.; Paoli, J.B.; Bodez, V.; Oozeer, R.; Garcia, R. [Institut Sainte-Catherine, 84 - Avignon (France)

    2002-11-01

    Three-dimensional conformal radiotherapy (3D CRT) is adversely affected by setup error and organ motion. In thoracic 3D CRT, breathing accounts for most of intra-fraction movements, thus impairing treatment quality. Breath control clearly exhibits dosimetric improvement compared to free breathing, leading to various techniques for gated treatments. We review benefits of different breath control methods -i.e. breath-holding or beam gating, with spirometric, isometric or X-ray respiration sensor- and argument the choice of expiration versus inspiration, with consideration to dosimetric concerns. All steps of 3D-CRT can be improved with breath control. Contouring of organs at risk (OAR) and target are easier and more accurate on breath controlled CT-scans. Inter- and intra-fraction target immobilisation allows smaller margins with better coverage. Lung outcome predictors (NTCP, Mean Dose, LV20, LV30) are improved with breath-control. In addition, inspiration breath control facilitates beam arrangement since it widens the distance between OAR and target, and leaves less lung normal tissue within the high dose region. Last, lung density, as of CT scan, is more accurate, improving dosimetry. Our institutions choice is to use spirometry driven, patient controlled high-inspiration breath-hold; this technique gives excellent immobilization results, with high reproducibility, yet it is easy to implement and costs little extra treatment time. Breath control, whatever technique is employed, proves superior to free breathing treatment when using 3D-CRT. Breath control should then be used whenever possible, and is probably mandatory for IMRT. (authors)

  8. Means of control of the public authorities as participants in public limited energy supply companies

    International Nuclear Information System (INIS)

    Kermel, C.

    1994-01-01

    Despite the fundamental studies by Emmerich and Puettner, the control of publicly owned companies by the state as a majority shareholder has not evolved to a generally accepted form. With a mind to the discussion on a nuclear phase-out at Hamburgische Electrizitaetswerke AG the author examines the scope offered by the law on public limited companies for realising the interests of the state as a shareholder. She arrives at interesting conclusions regarding the means to this end and the legal consequences of a phase-out decision. Lower supply companies are an ideal object of study for the purposes of this work. (orig./UA) [de

  9. Pulse current gas metal arc welding characteristics, control and applications

    CERN Document Server

    Ghosh, Prakriti Kumar

    2017-01-01

    This monograph is a first-of-its-kind compilation on high deposition pulse current GMAW process. The nine chapters of this monograph may serve as a comprehensive knowledge tool to use advanced welding engineering in prospective applications. The contents of this book will prove useful to the shop floor welding engineer in handling this otherwise critical welding process with confidence. It will also serve to inspire researchers to think critically on more versatile applications of the unique nature of pulse current in GMAW process to develop cutting edge welding technology.

  10. Controlling food, controlling relationships: exploring the meanings and dynamics of family food practices through the diary-interview approach.

    Science.gov (United States)

    MacDonald, Sarah; Murphy, Simon; Elliott, Eva

    2018-04-06

    Potential merits of a social practice perspective for examining the meanings and dynamics of family food include moving beyond individual behaviour, and exploring how practices emerge, develop and change. However, researchers have struggled to encourage reflection on mundane practices, and how to understand associated meanings. Drawing on a study of families in South Wales, this article reflects on the value of the diary-interview approach in addressing these methodological challenges, and aims to explore and understand the dynamics of control across family contexts. Contemporary practice theories distinguish between practices as 'performances' and practices as 'entities' and the diary-interview method facilitated an examination of these dimensions. Detailed accounts of daily 'performances' (through diaries), alongside reflection on underlying contexts and 'entities' (through interviews), illustrated the entanglement of control, practices and context. The article adds further complexity to the concept of practice 'bundles' which facilitated an understanding of how food was interrelated with other practices - across family contexts and across generations. Sociological approaches with a practices perspective at the core, offer potential for developing public health interventions by acknowledging: the relational meaning of food; the embeddedness of food within everyday practices; and the need to consider interventions across a range of policy areas. © 2018 Foundation for the Sociology of Health & Illness.

  11. Enhanced Phase-Shifted Current Control for Harmonic Cancellation in Three-Phase Multiple Adjustable Speed Drive Systems

    DEFF Research Database (Denmark)

    Yang, Yongheng; Davari, Pooya; Zare, Firuz

    2017-01-01

    A phase-shifted current control can be employed to mitigate certain harmonics induced by the Diode Rectifiers (DR) and Silicon-Controlled Rectifiers (SCR) as the front-ends of multiple parallel Adjustable Speed Drive (ASD) systems. However, the effectiveness of the phase-shifted control relies...... on the loading condition of each drive unit as well as the number of drives in parallel. In order to enhance the harmonic cancellation by means of the phase-shifted current control, the currents drawn by the rectifiers should be maintained almost at the same level. Thus, this paper firstly analyzes the impact...... of unequal loading among the parallel drives, and a scheme to enhance the performance is introduced to improve the quality of the total grid current, where partial loading operation should be enabled. Simulation and experimental case studies on multidrive systems have demonstrated that the enhanced phase...

  12. Depths of controlled drillings by means of underground drives; Teufen von gesteuerten Bohrungen mittels Untertageantrieben

    Energy Technology Data Exchange (ETDEWEB)

    Hengevoss, Charly [Weatherford Ukraine LLC, Kiev (Ukraine); Homrighausen, Reiner [BAUER Resources GmbH, Schrobenhausen (Germany)

    2013-03-01

    Today, the most modern directional drilling technology not only is used in case of very deep drillings (deeper or longer than 2,000 meter) by means of deep-level drilling rigs, but also with small, highly mobile universal drilling rigs. Thus, drilling costs are reduced, and unconventional hydrocarbons (methane gas - oil shale and shale gas) deposits are explores economically. Furthermore, known near-surface petroleum deposits in Northern Germany as well as in other parts of the Earth (such as in Romania, the U.S.A. or in Canada) which extraction of petroleum is very low already are interesting economically. Furthermore, today it is possible to investigate with controlled drillings more economically and with more safe sites for a possibly final storage of highly radioactive wastes. Controlled drillings may give an answer to geotechnical questions on highly inaccessible on optimum points for drilling wells in order to plan underground cavities or to investigate tunnel axes geotechnical or hydrological.

  13. Assembly and Quality Control of the LHC Cryostats at CERN Motivations, Means, Results and Lessons Learnt

    CERN Document Server

    Poncet, A; Parma, V; Strubin, P; Tock, JP; Tommasini, D

    2007-01-01

    In 2001, the project management decided to perform at CERN the final assembly of the LHC superconducting magnets with cryostat parts and cold masses produced by European Industry in large series. This industrial-like production has required a very significant investment in tooling, production facilities, engineering and quality control efforts, in contractual partnership with a consortium of firms. This unusual endeavour of a limited lifetime represented more than 850,000 working hours spanning over five years, the work being done on a result-oriented basis by the contractor. This paper presents the reasons for having conducted this project at CERN, summarizes the work breakdown structure, the production means and methods, the infrastructure specially developed, the tooling, logistics and quality control aspects of the work performed and the results achieved, in analytical form. Finally, the lessons learnt are outlined.

  14. Current status of fertility control methods in India

    Indian Academy of Sciences (India)

    Use of the condom increased to 3.1% from 2.4%. ... Current efforts in India to develop a male contraceptive are mainly directed towards ... the existing range of contraceptive methods available in the National Family Planning Programme. ... long acting, relatively easily removed and fertility returns rapidly after their removal.

  15. Current drive and profile control in low aspect ratio tokamaks

    International Nuclear Information System (INIS)

    Chan, V.S.; Chiu, S.C.; Lin-Liu, Y.R.; Miller, R.L.; Turnbull, A.D.

    1995-07-01

    The key to the theoretically predicted high performance of a low aspect ratio tokamak (LAT) is its ability to operate at very large plasma current*I p . The plasma current at low aspect ratios follows the approximate formula: I p ∼ (5a 2 B t /Rqψ) [(1 + κ 2 )/2] [A/(A - 1)] where A quadruple-bond R/a which was derived from equilibrium studies. For constant qψ and B t , I p can increase by an order of magnitude over the case of tokamaks with A approx-gt 2.5. The large current results in a significantly enhanced β t (quadruple-bond β N I p /aB t ) possibly of order unity. It also compensates for the reduction in A to maintain the same confinement performance assuming the confinement time τ follows the generic form ∼ HI p P -1 / 2 R 3 / 2 κ 1 / 2 . The initiation and maintenance of such a large current is therefore a key issue for LATs

  16. DSP based adaptive hysteresis-band current controlled active filter ...

    African Journals Online (AJOL)

    The use of non-linear loads critically affects the quality of supply by drawing harmonic currents and reactive power from the electrical distribution system. Active power filters are the most viable solution for solving such power quality problems in compliance with the harmonic standards. This article presents a digital signal ...

  17. A differential-delay control for ramped magnet current

    Energy Technology Data Exchange (ETDEWEB)

    Murray, J. [State Univ. of New York, Stony Brook, NY (United States). Dept. of Electrical Engineering; Olsen, R. [Brookhaven National Lab., Upton, NY (United States)

    1992-11-01

    A differential-delay control system has been designed and implemented for the main dipole magnet power supply of the booster ring at the National Synchrotron Light Source at Brookhaven National Lab. The control algorithm was implemented on a floating-point digital signal processor; in tests, the use of digital signal-processing techniques gave a factor of ten improvement in the tracking response time, together with a modest improvement in tracking accuracy.

  18. A differential-delay control for ramped magnet current

    Energy Technology Data Exchange (ETDEWEB)

    Murray, J. (State Univ. of New York, Stony Brook, NY (United States). Dept. of Electrical Engineering); Olsen, R. (Brookhaven National Lab., Upton, NY (United States))

    1992-01-01

    A differential-delay control system has been designed and implemented for the main dipole magnet power supply of the booster ring at the National Synchrotron Light Source at Brookhaven National Lab. The control algorithm was implemented on a floating-point digital signal processor; in tests, the use of digital signal-processing techniques gave a factor of ten improvement in the tracking response time, together with a modest improvement in tracking accuracy.

  19. Methods and means for improving the man-machine systems for NPP control

    International Nuclear Information System (INIS)

    Konstantinov, L.V.; Rakitin, I.D.

    1984-01-01

    Consideration is being given to the role of ''human factors'' and the ways of improving the man-machine interaction in NPP control and safety systems (CSS). Simulators and tAaining equipment on the basis of dynamic power unit models used for training and improving skill of NPP operatoAs, as well as for mastering collective actions of personnel under accidental conditions are considered in detail. The most perfect program complexes for fast NPP diagnostics and theiA pealization in the Federal Republic of Germany, Japan, Canada, the USA and other countries are described. A special attention is paid to the means and methods of videoterminal dialogue operator interaction with an object both in normal and extreme situations. It is noted that the problems of the man-machine interaction have become the subject of study only in the end of 70s after analyzing the causes of the Three-Mile-Island accident (USA). Publications dealing with the development of perspective control rooms for NPP were analyzed. It was concluded that radical changes both in equipment and principles of organizing the personnel activity will take place in the nearest future. They will be based on the progress in creating dialogue means and computers of the fourth and fifth generations as well as on engineering and psychological and technical aspects of designing

  20. The African swine fever control zone in South Africa and its current relevance

    Directory of Open Access Journals (Sweden)

    Noluvuyo R. Magadla

    2016-05-01

    Full Text Available African swine fever (ASF has been reported in South Africa since the early 20th century. The disease has been controlled and confined to northern South Africa over the past 80 years by means of a well-defined boundary line, with strict control measures and movement restrictions north of this line. In 2012, the first outbreak of ASF outside the ASF control zone since 1996 occurred. The objective of this study was to evaluate the current relevance of the ASF control line as a demarcation line between endemic ASF (north areas and ASF-free (south area and to determine whether there was a need to realign its trajectory, given the recent outbreaks of ASF, global climate changes and urban development since the line’s inception. A study of ASF determinants was conducted in an area 20 km north and 20 km south of the ASF control line, in Limpopo, Mpumalanga, North West and Gauteng provinces between May 2008 and September 2012. The study confirmed that warthogs, warthog burrows and the soft tick reservoir, Ornithodoros moubata, are present south of the ASF control line, but no virus or viral DNA was detected in these ticks. There appears to be an increasing trend in the diurnal maximum temperature and a decrease in humidity along the line, but the impact of these changes is uncertain. No discernible changes in minimum temperatures and average rainfall along the disease control line were observed between 1992 and 2014. Even though the reservoirs were found south of the ASF boundary line, the study concluded that there was no need to realign the trajectory of the ASF disease control line, with the exception of Limpopo Province. However, the provincial surveillance programmes for the reservoir, vector and ASF virus south of this line needs to be maintained and intensified as changing farming practices may favour the spread of ASF virus beyond the control line. Keywords: African swine fever; warthog burrow; Ornithodoros moubata;control line

  1. Controlling charge current through a DNA based molecular transistor

    Energy Technology Data Exchange (ETDEWEB)

    Behnia, S., E-mail: s.behnia@sci.uut.ac.ir; Fathizadeh, S.; Ziaei, J.

    2017-01-05

    Molecular electronics is complementary to silicon-based electronics and may induce electronic functions which are difficult to obtain with conventional technology. We have considered a DNA based molecular transistor and study its transport properties. The appropriate DNA sequence as a central chain in molecular transistor and the functional interval for applied voltages is obtained. I–V characteristic diagram shows the rectifier behavior as well as the negative differential resistance phenomenon of DNA transistor. We have observed the nearly periodic behavior in the current flowing through DNA. It is reported that there is a critical gate voltage for each applied bias which above it, the electrical current is always positive. - Highlights: • Modeling a DNA based molecular transistor and studying its transport properties. • Choosing the appropriate DNA sequence using the quantum chaos tools. • Choosing the functional interval for voltages via the inverse participation ratio tool. • Detecting the rectifier and negative differential resistance behavior of DNA.

  2. Controlled parity switch of persistent currents in quantum ladders

    Science.gov (United States)

    Filippone, Michele; Bardyn, Charles-Edouard; Giamarchi, Thierry

    2018-05-01

    We investigate the behavior of persistent currents for a fixed number of noninteracting fermions in a periodic quantum ladder threaded by Aharonov-Bohm and transverse magnetic fluxes Φ and χ . We show that the coupling between ladder legs provides a way to effectively change the ground-state fermion-number parity, by varying χ . Specifically, we demonstrate that varying χ by 2 π (one flux quantum) leads to an apparent fermion-number parity switch. We find that persistent currents exhibit a robust 4 π periodicity as a function of χ , despite the fact that χ →χ +2 π leads to modifications of order 1 /N of the energy spectrum, where N is the number of sites in each ladder leg. We show that these parity-switch and 4 π periodicity effects are robust with respect to temperature and disorder, and outline potential physical realizations using cold atomic gases and photonic lattices, for bosonic analogs of the effects.

  3. Design and Implementation of Digital Current Mode Controller for DC-DC Converters

    DEFF Research Database (Denmark)

    Taeed, Fazel

    to be regulated by a closed-loop controller. The Peak Current Mode Control (PCMC) is one of the most promising control methods for dc-dc converters. It has been known for high bandwidth (speed), and inherent current protection. Increasing the controller bandwidth decreases the output filter size and cost. Analog...

  4. The TS 600: automatic control system for eddy currents

    International Nuclear Information System (INIS)

    Poulet, J.P.

    1986-10-01

    In the scope of fabrication and in service inspection of the PWR steam generator tubing bendle, FRAMATOME developed an automatic Eddy Current testing system: TS600. Based on a mini-computer, TS600 allows to digitize, to store and to process data in various ways, so it is possible to perform several kinds of inspection: conventional inservice inspection, roll area profilometry...... TS600 can also be used to develop new methods of examination [fr

  5. Field-controlled spin current in frustrated spin chains

    Directory of Open Access Journals (Sweden)

    A.K. Kolezhuk

    2009-01-01

    Full Text Available We study states with spontaneous spin current, emerging in frustrated antiferromagnetic spin-S chains subject to a strong external magnetic field. As a numerical tool, we use a non-Abelian symmetry realization of the density matrix renormalization group. The field dependence of the order parameter and the critical exponents are presented for zigzag chains with S=1/2, 1, 3/2, and 2.

  6. Electric field control photo-induced Hall currents in semiconductors

    Energy Technology Data Exchange (ETDEWEB)

    Miah, M. Idrish [Nanoscale Science and Technology Centre, Griffith University, Nathan, Brisbane, QLD 4111 (Australia); Department of Physics, University of Chittagong, Chittagong, Chittagong 4331 (Bangladesh)], E-mail: m.miah@griffith.edu.au

    2008-10-15

    We generate spin-polarized carrier populations in GaAs and low temperature-grown GaAs (LT-GaAs) by circularly polarized optical beams and pull them by external electric fields to create spin-polarized currents. In the presence of the optically generated spin currents, anomalous Hall currents with an enhancement with increasing doping are observed and found to be almost steady in moderate electric fields up to {approx}120 mV {mu}m{sup -1}, indicating that photo-induced spin orientation of electrons is preserved in these systems. However, a field {approx}300 mV {mu}m{sup -1} completely destroys the electron spin polarization due to an increase of the D'yakonov-Perel' spin precession frequency of the hot electrons. This suggests that high field carrier transport conditions might not be suitable for spin-based technology with GaAs and LT-GaAs. It is also demonstrated that the presence of the excess arsenic sites in LT-GaAs might not affect the spin relaxation by Bir-Aronov-Pikus mechanism owing to a large number of electrons in n-doped materials.

  7. ICRF Mode Conversion Current Drive for Plasma Stability Control in Tokamaks

    International Nuclear Information System (INIS)

    Grekov, D.; Kock, R.; Lyssoivan, A.; Noterdaeme, J. M.; Ongena, J.

    2007-01-01

    There is a substantial incentive for the International Thermonuclear Experimental Reactor (ITER) to operate at the highest attainable beta (plasma pressure normalized to magnetic pressure), a point emphasized by requirements of attractive economics in a reactor. Recent experiments aiming at stationary high beta discharges in tokamak plasmas have shown that maximum achievable beta value is often limited by the onset of instabilities at rational magnetic surfaces (neoclassical tearing modes). So, methods of effective control of these instabilities have to be developed. One possible way for neoclassical tearing modes control is an external current drive in the island to locally replace the missing bootstrap current and thus to suppress the instability. Also, a significant control of the sawtooth behaviour was demonstrated when the magnetic shear was modified by driven current at the magnetic surface where safety factor equals to 1. In the ion cyclotron range of frequencies (ICRF), the mode conversion regime can be used to drive the local external current near the position of the fast-to-slow wave conversion layer, thus providing an efficient means of plasma stability control. The slow wave energy is effectively absorbed in the vicinity of mode conversion layer by electrons with such parallel to confining magnetic field velocities that the Landau resonance condition is satisfied. For parameters of present day tokamaks and for ITER parameters the slow wave phase velocity is rather low, so the large ratio of momentum to energy content would yield high current drive efficiency. In order to achieve noticeable current drive effect, it is necessary to create asymmetry in the ICRF power absorption between top and bottom parts of the plasma minor cross-section. Such asymmetric electron heating may be realized using: - shifted from the torus midplane ICRF antenna in TEXTOR tokamak; - plasma displacement in vertical direction that is feasible in ASDEX-Upgrade; - the

  8. Improved adaptive input voltage control of a solar array interfacing current mode controlled boost power stage

    International Nuclear Information System (INIS)

    Sitbon, Moshe; Schacham, Shmuel; Suntio, Teuvo; Kuperman, Alon

    2015-01-01

    Highlights: • Photovoltaic generator dynamic resistance online estimation method is proposed. • Control method allowing to achieve nominal performance at all time is presented. • The method is suitable for any type of photovoltaic system. - Abstract: Nonlinear characteristics of photovoltaic generators were recently shown to significantly influence the dynamics of interfacing power stages. Moreover, since the dynamic resistance of photovoltaic generators is both operating point and environmental variables dependent, the combined dynamics exhibits these dependencies as well, burdening control challenge. Typically, linear time invariant input voltage loop controllers (e.g. Proportional-Integrative-Derivative) are utilized in photovoltaic applications, designed according to nominal operating conditions. Nevertheless, since actual dynamics is seldom nominal, closed loop performance of such systems varies as well. In this paper, adaptive control method is proposed, allowing to estimate photovoltaic generator resistance online and utilize it to modify the controller parameters such that closed loop performance remains nominal throughout the whole operation range. Unlike previously proposed method, utilizing double-grid-frequency component for estimation purposes and suffering from various drawbacks such as operation point dependence and applicability to single-phase grid connected systems only, the proposed method is based on harmonic current injection and is independent on operating point and system topology

  9. Design studies on high current and grid control electron gun

    International Nuclear Information System (INIS)

    Wang Jinnan; Lu Kun; Chi Yunlong; Zhou Zusheng

    2011-01-01

    Electron gun, the source of electrons, is a kind of ultrahigh vacuum device and plays an important role in different kind of accelerators. With the irradiation accelerator demands, describes the design studies on beam optics optimization. The simulation result shows that the beam current is above 5 A with cathode voltage of 80 kV and beam emittance, gun electric field and beam waist radius meet the accelerator needs. The electron gun manufactured and installed in the test stand, the conditioning and test will be done in the near future. (authors)

  10. Ring Current He Ion Control by Bounce Resonant ULF Waves

    Science.gov (United States)

    Kim, Hyomin; Gerrard, Andrew J.; Lanzerotti, Louis J.; Soto-Chavez, Rualdo; Cohen, Ross J.; Manweiler, Jerry W.

    2017-12-01

    Ring current energy He ion (˜65 keV to ˜520 keV) differential flux data from the Radiation Belt Storm Probe Ion Composition Experiment (RBSPICE) instrument aboard the Van Allan Probes spacecraft show considerable variability during quiet solar wind and geomagnetic time periods. Such variability is apparent from orbit to orbit (˜9 h) of the spacecraft and is observed to be ˜50-100% of the nominal flux. Using data from the Electric and Magnetic Field Instrument Suite and Integrated Science (EMFISIS) instrument, also aboard the Van Allen Probes spacecraft, we identify that a dominant source of this variability is from ULF waveforms with periods of tens of seconds. These periods correspond to the bounce resonant timescales of the ring current He ions being measured by RBSPICE. A statistical survey using the particle and field data for one full spacecraft precession period (approximately 2 years) shows that the wave and He ion flux variations are generally anticorrelated, suggesting the bounce resonant pitch angle scattering process as a major component in the scattering of He ions.

  11. Current status of patient-controlled analgesia in cancer patients.

    Science.gov (United States)

    Ripamonti, C; Bruera, E

    1997-03-01

    Patient-controlled analgesia (PCA) is a relatively new technique in which patients are able to self-administer small doses of opioid analgesics when needed. Many different devices are available for opioid infusion, including a syringe pump, disposable plastic cylinder, and battery-operated computer-driven pump. These devices allow patients to choose an intermittent (demand) bolus, continuous infusion, or both modes of administration. Parameters, such as route, drug concentration dose, frequency, and maximum daily or hourly dose, are programmed by the physician. The patient decides whether or not to take a dose. Devices can be used to deliver the drug into a running intravenous infusion, the epidural space, or subcutaneously. Controlled trials indicate that PCA is probably superior to regular opioid administration in postoperative pain. Reported advantages include greater patient satisfaction, decreased sedation and anxiety, and reduced nursing time and hospitalization. Preliminary experience suggests that PCA is also useful and safe for cancer pain, but further research is greatly needed.

  12. Computational investigation of flow control by means of tubercles on Darrieus wind turbine blades

    Science.gov (United States)

    Sevinç, K.; Özdamar, G.; Şentürk, U.; Özdamar, A.

    2015-09-01

    This work presents the current status of the computational study of the boundary layer control of a vertical axis wind turbine blade by modifying the blade geometry for use in wind energy conversion. The control method is a passive method which comprises the implementation of the tubercle geometry of a humpback whale flipper onto the leading edge of the blades. The baseline design is an H-type, three-bladed Darrieus turbine with a NACA 0015 cross-section. Finite-volume based software ANSYS Fluent was used in the simulations. Using the optimum control parameters for a NACA 634-021 profile given by Johari et al. (2006), turbine blades were modified. Three dimensional, unsteady, turbulent simulations for the blade were conducted to look for a possible improvement on the performance. The flow structure on the blades was investigated and flow phenomena such as separation and stall were examined to understand their impact on the overall performance. For a tip speed ratio of 2.12, good agreement was obtained in the validation of the baseline model with a relative error in time- averaged power coefficient of 1.05%. Modified turbine simulations with a less expensive but less accurate turbulence model yielded a decrease in power coefficient. Results are shown comparatively.

  13. A Control Variate Method for Probabilistic Performance Assessment. Improved Estimates for Mean Performance Quantities of Interest

    Energy Technology Data Exchange (ETDEWEB)

    MacKinnon, Robert J.; Kuhlman, Kristopher L

    2016-05-01

    We present a method of control variates for calculating improved estimates for mean performance quantities of interest, E(PQI) , computed from Monte Carlo probabilistic simulations. An example of a PQI is the concentration of a contaminant at a particular location in a problem domain computed from simulations of transport in porous media. To simplify the presentation, the method is described in the setting of a one- dimensional elliptical model problem involving a single uncertain parameter represented by a probability distribution. The approach can be easily implemented for more complex problems involving multiple uncertain parameters and in particular for application to probabilistic performance assessment of deep geologic nuclear waste repository systems. Numerical results indicate the method can produce estimates of E(PQI)having superior accuracy on coarser meshes and reduce the required number of simulations needed to achieve an acceptable estimate.

  14. Fog-computing concept usage as means to enhance information and control system reliability

    Science.gov (United States)

    Melnik, E. V.; Klimenko, A. B.; Ivanov, D. Ya

    2018-05-01

    This paper focuses on the reliability issue of information and control systems (ICS). The authors propose using the elements of the fog-computing concept to enhance the reliability function. The key idea of fog-computing is to shift computations to the fog-layer of the network, and thus to decrease the workload of the communication environment and data processing components. As for ICS, workload also can be distributed among sensors, actuators and network infrastructure facilities near the sources of data. The authors simulated typical workload distribution situations for the “traditional” ICS architecture and for the one with fogcomputing concept elements usage. The paper contains some models, selected simulation results and conclusion about the prospects of the fog-computing as a means to enhance ICS reliability.

  15. Mean Field Type Control with Congestion (II): An Augmented Lagrangian Method

    Energy Technology Data Exchange (ETDEWEB)

    Achdou, Yves, E-mail: achdou@ljll.univ-paris-diderot.fr; Laurière, Mathieu [Univ. Paris Diderot, Sorbonne Paris Cité, Laboratoire Jacques-Louis Lions, UMR 7598, UPMC, CNRS (France)

    2016-12-15

    This work deals with a numerical method for solving a mean-field type control problem with congestion. It is the continuation of an article by the same authors, in which suitably defined weak solutions of the system of partial differential equations arising from the model were discussed and existence and uniqueness were proved. Here, the focus is put on numerical methods: a monotone finite difference scheme is proposed and shown to have a variational interpretation. Then an Alternating Direction Method of Multipliers for solving the variational problem is addressed. It is based on an augmented Lagrangian. Two kinds of boundary conditions are considered: periodic conditions and more realistic boundary conditions associated to state constrained problems. Various test cases and numerical results are presented.

  16. Harmonic current control for LCL-filtered VSCs connected to ultra-weak grids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Yang, Dongsheng; Blaabjerg, Frede

    2017-01-01

    This paper addresses the harmonic current control for LCL-filtered Voltage-Source Converters (VSCs) connected to ultra-weak (high-impedance) grids. It is shown that the harmonic current controllers tend to be unstable as the Short-Circuit Ratio (SCR) of the system reduces. An active stabilizing...... control scheme is thus proposed by feeding back the filter capacitor voltage and the converter-side current. The method not only stabilizes the harmonic current control with a wide range of SCR values, but also mitigates harmonic distortions in the grid-side current of the VSC. The stabilizing mechanism...

  17. 21 CFR 1300.04 - Definitions relating to the dispensing of controlled substances by means of the Internet.

    Science.gov (United States)

    2010-04-01

    ... controlled substances by means of the Internet. 1300.04 Section 1300.04 Food and Drugs DRUG ENFORCEMENT... substances by means of the Internet. (a) Any term not defined in this part or elsewhere in this chapter shall... evaluation of the patient. (c) The term deliver, distribute, or dispense by means of the Internet refers...

  18. Infectious bronchitis virus variants ? History, current situation and control measures

    OpenAIRE

    2011-01-01

    Abstract Infectious bronchitis virus (IBV) is ubiquitous in most parts of the world where poultry are reared and is able to spread very rapidly in non-protected birds. It is shed via both the respiratory tract and the faeces and can persist in the birds and the intestinal tract for several weeks or months. Outdoors, survival of IBV for 56 days in litter has been reported. Although strict biosecurity and working with a one-age system are essential control measures, normally vaccinat...

  19. 'Downward control' of the mean meridional circulation and temperature distribution of the polar winter stratosphere

    Science.gov (United States)

    Garcia, Rolando R.; Boville, Byron A.

    1994-01-01

    According to the 'downward control' principle, the extratropical mean vertical velocity on a given pressure level is approximately proportional to the meridional gradient of the vertically integrated zonal force per unit mass exerted by waves above that level. In this paper, a simple numerical model that includes parameterizations of both planetary and gravity wave breaking is used to explore the influence of gravity wave breaking in the mesosphere on the mean meridional circulation and temperature distribution at lower levels in the polar winter stratosphere. The results of these calculations suggest that gravity wave drag in the mesosphere can affect the state of the polar winter stratosphere down to altitudes below 30 km. The effect is most important when planetary wave driving is relatively weak: that is, during southern winter and in early northern winter. In southern winter, downwelling weakens by a factor of 2 near the stratospause and by 20% at 30 km when gravity wave drag is not included in the calculations. As a consequence, temperatures decrease considerably throughout the polar winter stratosphere (over 20 K above 40 km and as much as 8 K at 30 km, where the effect is enhanced by the long radiative relaxation timescale). The polar winter states obtained when gravity wave drag is omitted in this simple model resemble the results of simulations with some general circulation models and suggest that some of the shortcomings of the latter may be due to a deficit in mesospheric momentum deposition by small-scale gravity waves.

  20. Orthogonal control of expression mean and variance by epigenetic features at different genomic loci.

    Science.gov (United States)

    Dey, Siddharth S; Foley, Jonathan E; Limsirichai, Prajit; Schaffer, David V; Arkin, Adam P

    2015-05-05

    While gene expression noise has been shown to drive dramatic phenotypic variations, the molecular basis for this variability in mammalian systems is not well understood. Gene expression has been shown to be regulated by promoter architecture and the associated chromatin environment. However, the exact contribution of these two factors in regulating expression noise has not been explored. Using a dual-reporter lentiviral model system, we deconvolved the influence of the promoter sequence to systematically study the contribution of the chromatin environment at different genomic locations in regulating expression noise. By integrating a large-scale analysis to quantify mRNA levels by smFISH and protein levels by flow cytometry in single cells, we found that mean expression and noise are uncorrelated across genomic locations. Furthermore, we showed that this independence could be explained by the orthogonal control of mean expression by the transcript burst size and noise by the burst frequency. Finally, we showed that genomic locations displaying higher expression noise are associated with more repressed chromatin, thereby indicating the contribution of the chromatin environment in regulating expression noise. © 2015 The Authors. Published under the terms of the CC BY 4.0 license.

  1. Plug-and-Play Design of Current Controllers for Grid-feeding Converters in DC Microgrids

    DEFF Research Database (Denmark)

    Han, Renke; Tucci, Michele; Soloperto, Raffaele

    2017-01-01

    In this paper, we address the problem of synthesizing decentralized current controllers for grid-feeding converters of current-controlled distributed generation units (CDGUs) in dc microgrids (MGs). Notably, a plug-and-play (PnP) design procedure is proposed to achieve grid-feeding current tracking...

  2. Electronically Tunable Current Controlled Current Conveyor Transconductance Amplifier-Based Mixed-Mode Biquadratic Filter with Resistorless and Grounded Capacitors

    Directory of Open Access Journals (Sweden)

    Hua-Pin Chen

    2017-03-01

    Full Text Available A new electronically tunable mixed-mode biquadratic filter with three current controlled current conveyor transconductance amplifiers (CCCCTAs and two grounded capacitors is proposed. With current input, the filter can realise lowpass (LP, bandpass (BP, highpass (HP, bandstop (BS and allpass (AP responses in current mode and LP, BP and HP responses in transimpedance mode. With voltage input, the filter can realise LP, BP, HP, BS and AP responses in voltage and transadmittance modes. Other attractive features of the mixed-mode biquadratic filter are (1 the use of two grounded capacitors, which is ideal for integrated circuit implementation; (2 orthogonal control of the quality factor (Q and resonance angular frequency (ωo for easy electronic tenability; (3 low input impedance and high output impedance for current signals; (4 high input impedance for voltage signal; (5 avoidance of need for component-matching conditions; (6 resistorless and electronically tunable structure; (7 low active and passive sensitivities; and (8 independent control of the voltage transfer gains without affecting the parameters ωo and Q.

  3. Comparison of Unmodulated Current Control Characteristics of Permanent Magnet Synchronous Motor

    Directory of Open Access Journals (Sweden)

    Anwar Muqorobin

    2014-12-01

    Full Text Available This paper discusses comparison of unmodulated current controls in PMSM, more specifically, on-off, sliding mode, predictive and hybrid controls. The purpose of this study is to select the most appropriate control technique to be adopted. The comparison method is preceded by modeling the motor and entering the values of the motor parameters. PI control is used for speed control and zero d-axis current is employed. Furthermore, performing simulation for each type ofthe selected current controls and analyzing their responses in terms of dq and abc currents, q-axis current response with step reference, as well as THD. Simulation results show that the on-off control gives the best overall performance based on its abc-axis current ripple and THD at large load torque. The hybrid control shows the best response occurring only at the fastest transient time of q-axis current but its response exhibits bad qualities compared with other controls. The predictive control yields the best responses offering the smallest d-axis ripple current and THD at small load torque condition. The sliding mode control, however, does not exhibit any prominent performance compared to the others. Results presented in this paper further indicate that for the PMSM used in the simulation the most appropriate control is the predictive control.

  4. Coherent control of single electrons: a review of current progress

    Science.gov (United States)

    Bäuerle, Christopher; Glattli, D. Christian; Meunier, Tristan; Portier, Fabien; Roche, Patrice; Roulleau, Preden; Takada, Shintaro; Waintal, Xavier

    2018-05-01

    In this report we review the present state of the art of the control of propagating quantum states at the single-electron level and its potential application to quantum information processing. We give an overview of the different approaches that have been developed over the last few years in order to gain full control over a propagating single-electron in a solid-state system. After a brief introduction of the basic concepts, we present experiments on flying qubit circuits for ensemble of electrons measured in the low frequency (DC) limit. We then present the basic ingredients necessary to realise such experiments at the single-electron level. This includes a review of the various single-electron sources that have been developed over the last years and which are compatible with integrated single-electron circuits. This is followed by a review of recent key experiments on electron quantum optics with single electrons. Finally we will present recent developments in the new physics that has emerged using ultrashort voltage pulses. We conclude our review with an outlook and future challenges in the field.

  5. Mitigation of Grid-Current Distortion for LCL-Filtered Voltage-Source Inverter with Inverter-Current Feedback Control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2018-01-01

    harmonics can freely flow into the filter capacitor. In this case, because of the loss of harmonic information, traditional harmonic controllers fail to mitigate the grid current distortion. Although this problem may be avoided using the grid voltage feedforward scheme, the required differentiators may...

  6. Digital peak current mode control with adaptive slope compensation for DC-DC converters

    DEFF Research Database (Denmark)

    Andersen, Karsten Holm; Nymand, Morten

    2017-01-01

    performance and stability of current mode control. The presented method adapt to DC-DC converter operating conditions by estimating the rising and falling inductor current slopes, to apply a current slope compensation value to obtain a constant quality factor. The experimental results verifies the theoretical......This paper presents an adaptive slope compensation method for peak current mode control of digital controlled DC-DC converters, which controls the quality factor of the complex conjugated poles at half the switching frequency. Using quality factor control enables optimization of the dynamic...

  7. Heating, current drive and MHD control using ECH in TCV

    International Nuclear Information System (INIS)

    Goodman, T.

    2001-01-01

    The 6 beam 2nd harmonic X-mode (X2), 3MW, ECH/ECCD system of the TCV tokamak allows a fine tailoring of the deposition profiles in the plasma. The sensitivity of the sawtooth period to the deposition location is used to increase the equilibria reconstruction and ray-tracing accuracy. Off-axis ECH, followed by on-axis counter-ECCD produces improved central confinement regimes in which τ Ee exceeds RLW scaling by a factor of 3.5. The PRETOR transport code (incorporating an RLW local transport model but constrained by the experimental density profiles) predicts an extreme sensitivity of τ Ee to the deposition location of the counter-ECCD. This is confirmed by experiments. Sawtooth simulations using PRETOR, including the effects of current drive with inputs from the TORAY ray-tracing code, are in good agreement with experimental results. These results are an initial benchmark for the package of analysis codes, LIUQE/TORAY/PRETOR used during ECH/ECCD experiments on TCV. (author)

  8. Current physical activity improves balance control during sensory conflicting conditions in older adults.

    Science.gov (United States)

    Buatois, S; Gauchard, G C; Aubry, C; Benetos, A; Perrin, P

    2007-01-01

    Aging process is characterized by difficulties in ensuring balance control, especially in conditions of reduced or conflicting sensory information, leading to an increased risk of falling. Conversely, the practise of physical activities (PA) has been recognized as a good approach to improve the quality of balance control. This study aimed to investigate the influence of current and/or past PA on balance-related neurosensorial organization in older adults on the maintenance of the upright stance, especially during sensory conflicting situations. Postural control was evaluated by means of the Sensory Organization Test on 130 healthy noninstitutionalized volunteers aged over 65, split into four groups according to the presence or absence of PA before or after retirement. Subjects who practised PA for a long time (Gr1) and subjects who started PA after retirement (Gr2) displayed the best postural performances and better managed sensory conflicting situations compared to subjects who had stopped PA for many years (Gr3) and subjects who had never practised PA (Gr4). Multiple regression analyses revealed that current PA was the major determinant for postural parameters during sensorial conflict compared to age, gender, body mass index and past PA. Regular PA, even when started late in life, allows appropriate reorganization of the different components of postural control during sensory conflicting situations. Indeed, active subjects were more able to compensate for suppressed or perturbed sensory information by an increased usage of another referential and so to correct their posture by adopting a more appropriate balance strategy. Thus, PA counteracts the age-related decline of postural control and could consequently reduce the risk of falling.

  9. Control of superconductivity by means of electric-field-induced strain in superconductor/piezoelectric hybrids

    Science.gov (United States)

    Stamopoulos, D.; Zeibekis, M.; Zhang, S. J.

    2018-01-01

    The controlled modification of superconductivity by any means, specifically in hybrid systems, has attracted much interest in the recent decades. Here, we present experimental data and phenomenological modeling on the control of TC of superconducting (SC) Nb thin films, with thickness 3 nm ≤ dN b≤50 nm, under the application of in-plane strain, S(Eex) induced by an external out-of-plane electric field, Eex to piezoelectric (PE) single crystals, namely, ( 1 -x )Pb(Mg1/3Nb2/3)O3-xPbTiO3 (PMN-xPT), with x = 0.27 and 0.31. We report experimental modification of TC of Nb by Eex, accurately described by a phenomenological model that incorporates the constitutive relation S(Eex) of PMN-xPT. The systematic experimental-phenomenological modeling approach introduced here is generic and paves the way for an understanding of the underlying physical mechanisms in any SC/PE hybrid.

  10. Resistive flux saving and current profile control during lower hybrid waves assisted current rise in TORE SUPRA

    International Nuclear Information System (INIS)

    van Houtte, D.; Hoang, G.T.; Joffrin, E.; Lecoustey, P.; Moreau, D.; Parlange, F.; Tonon, G.; Vallet, J.C.

    1992-01-01

    Resistive flux saving at densities n e = (1 - 2) x 10 19 m -3 has been studied. High flux saving efficiency (0.7 x 10 13 Wb/J/m -1 ) can be achieved for a low rf power (P LH = 0.5 MW) due to the beneficial effect of the electric field on the suprathermal electrons. However for power higher than 1 MW, the efficiency is 0.25 x 10 13 Wb/J/m -1 . This flux saving efficiency is comparable to the one obtained during the flat top phase. The application of the LH power during a low density current ramp-up tends to peak the electron temperature and current density profiles. The rf power level, the parallel wavenumber and the current ramp rate allow to control the trajectories of the plasma discharges during the current rise inside the MHD stable domain

  11. Material Culture and Cultural Meanings: Current Studies of Archaeological Ceramics and in Ce­ramic Ethnoarchaeology

    Directory of Open Access Journals (Sweden)

    Charles C. Kolb

    2000-05-01

    Full Text Available Pottery and People: A Dynamic Interaction. James M. Skibo and Gary M. Feinman (editors. Founda­tions of Archaeological Inquiry. Salt Lake City. University of Utah Press. 1999. 260 pp. 91 figures. 30 tables. ISBN 0-87480-576-7. $55.00 (cloth; 0-87489-577-5. $25.00 (paperback. Material Meanings: Critical Approaches to the Interpretation of Material Culture. Elizabeth S. Chilton (editor. Foundations of Archaeological Inquiry. Salt Lake City: University of Utah Press. 1999.179pp. 35 figures. 11 tables. ISBN 0-87480-632-1. $55.00 (cloth; 087480-633-X. $35.00 (paperback. The description and interpretation of material culture may be regarded as the essence of archaeology, a discipline that seeks to recover, describe, document, and interpret past human culture. More recently, understanding that actions occur in a material world that is constituted symbolically, archaeological explanations are often framed in sociocultural meanings, the analysis of agencies, practices and behaviors. I shall subsequently return to this issue. Because of their longevity in the archaeological record, lithic and ceramic artifacts are crucial to the endeavor to interpret human culture. Objects fashioned from clay and subjected to intentional artificial sources of heat made their initial appearance in the archaeological record more than 26.000 years ago. Ceramic objects have been created in a seemingly endless variety of shapes and forms, varying from fertility figurines. to cooking and food storage vessels. lamps, smoking pipes, medicinal pastilles, tokens, beehives, and coffins to modern whitewares and pyroceramics.

  12. Speed Control Analysis of Brushless DC Motor Based on Maximum Amplitude DC Current Feedback

    Directory of Open Access Journals (Sweden)

    Hassan M.A.A.

    2014-07-01

    Full Text Available This paper describes an approach to develop accurate and simple current controlled modulation technique for brushless DC (BLDC motor drive. The approach is applied to control phase current based on generation of quasi-square wave current by using only one current controller for the three phases. Unlike the vector control method which is complicated to be implemented, this simple current modulation technique presents advantages such as phase currents are kept in balance and the current is controlled through only one dc signal which represent maximum amplitude value of trapezoidal current (Imax. This technique is performed with Proportional Integral (PI control algorithm and triangular carrier comparison method to generate Pulse Width Modulation (PWM signal. In addition, the PI speed controller is incorporated with the current controller to perform desirable speed operation of non-overshoot response. The performance and functionality of the BLDC motor driver are verified via simulation by using MATLAB/SIMULINK. The simulation results show the developed control system performs desirable speed operation of non-overshoot and good current waveforms.

  13. Turbine Engine Clearance Control Systems: Current Practices and Future Directions

    Science.gov (United States)

    Lattime, Scott B.; Steinetz, Bruce M.

    2002-01-01

    Improved blade tip sealing in the high pressure compressor (HPC) and high pressure turbine (HPT) can provide dramatic reductions in specific fuel consumption (SFC), time-on-wing, compressor stall margin, and engine efficiency as well as increased payload and mission range capabilities. Maintenance costs to overhaul large commercial gas turbine engines can easily exceed $1M. Engine removal from service is primarily due to spent exhaust gas temperature (EGT) margin caused mainly by the deterioration of HPT components. Increased blade tip clearance is a major factor in hot section component degradation. As engine designs continue to push the performance envelope with fewer parts and the market drives manufacturers to increase service life, the need for advanced sealing continues to grow. A review of aero gas turbine engine HPT performance degradation and the mechanisms that promote these losses are discussed. Benefits to the HPT due to improved clearance management are identified. Past and present sealing technologies are presented along with specifications for next generation engine clearance control systems.

  14. Load Torque Compensator for Model Predictive Direct Current Control in High Power PMSM Drive Systems

    DEFF Research Database (Denmark)

    Preindl, Matthias; Schaltz, Erik

    2010-01-01

    In drive systems the most used control structure is the cascade control with an inner torque, i.e. current and an outer speed control loop. The fairly small converter switching frequency in high power applications, e.g. wind turbines lead to modest speed control performance. An improvement bring...... the use of a current controller which takes into account the discrete states of the inverter, e.g. DTC or a more modern approach: Model Predictive Direct Current Control (MPDCC). Moreover overshoots and oscillations in the speed are not desired in many applications, since they lead to mechanical stress...

  15. A Coordinate Control Strategy for Circulating Current Suppression in Multiparalleled Three-Phase Inverters

    DEFF Research Database (Denmark)

    Zhang, Xueguang; Wang, Tianyi; Wang, Xiongfei

    2017-01-01

    This paper addresses the zero-sequence circulating current control in the multiparalleled three-phase voltage-source inverters. The model of the zero-sequence circulating current in the N-paralleled (N ≥ 3) inverters is derived. It is shown that the circulating current is not only susceptible...... to the mismatches of circuit parameters, but it is also influenced by the interactions of circulating current controllers used by other paralleled inverters. To eliminate these adverse effects on the circulating current control loop, a coordinate control strategy for the N-paralleled inverter is proposed based...... on the zero-vector feedforward method with the space-vector pulse width modulation. Moreover, a virtual inverter method is introduced to facilitate the implementation of the proposed controller, which decouples the interactions of circulating current controllers in the paralleled inverters. Finally...

  16. Current knowledge on groundwater microbial pathogens and their control

    Science.gov (United States)

    Macler, Bruce A.; Merkle, Jon C.

    Those who drink groundwater that has not been disinfected are at increased risk of infection and disease from pathogenic microorganisms. Recent studies have shown that up to half of all US drinking-water wells tested had evidence of fecal contamination. A significant fraction of all waterborne disease outbreaks is associated with groundwater. An estimated 750,000 to 5.9million illnesses per year result from contaminated groundwaters in the US. Mortality from these illnesses may be 1400-9400 deaths per year. Control of these pathogens starts with source-water protection activities to prevent fecal contamination of aquifers and wells. These include assessment of wellhead vulnerability to fecal contamination and correction of identified deficiencies. Correction may include control of sources or rehabilitation of the well itself. Disinfection can serve as a useful barrier and is recommended as a prudent public-health policy for all groundwater systems. Ceux qui boivent une eau souterraine non désinfectée présentent un risque accru d'infection et de maladie par des germes pathogènes. De récentes études ont montré que près de la moitié de tous les puits américains testés, captés pour l'eau potable, sont soumis à une contamination fécale. Une fraction significative de l'ensemble des premières manifestations de maladies liées à l'eau est associée aux eaux souterraines. On estime qu'entre 750 000 et 5,9millions de personnes sont malades chaque année aux États-Unis à cause d'eaux souterraines polluées. La mortalité parmi ces malades doit ètre de l'ordre de 1400 à 9400 décès par an. La protection contre ces germes pathogènes commence avec des mesures prises au niveau du captage pour empècher la pollution des aquifères et des puits. Celles-ci comprennent une évaluation de la vulnérabilité des tètes de puits à la pollution fécale et une correction des insuffisances mises en évidence. Cette correction peut comprendre une maîtrise des sources

  17. A current controlled matrix converter for wind energy conversion systems based on permanent magnet synchronous generator

    OpenAIRE

    Naggar H. Saad; Ahmed A. El-Sattar; Mohamed I. Marei

    2016-01-01

    The main challenges of wind energy conversion systems (WECS) are to maximize the energy capture from the wind and injecting reactive power during the fault. This paper presents a current controlled matrix converter to interface Permanent Magnet Synchronous Generators (PMSG) based WECS with the grid. To achieve fast dynamic response with reduced current ripples, a hysteresis current control is utilized. The proposed control system decouples the active and reactive components of the PMSG curren...

  18. Considering mortage as one of the means of securing the execution of obligations recognized in the current Albanian legislation

    Directory of Open Access Journals (Sweden)

    Neritan Cena

    2017-07-01

    Full Text Available The mortgage is one of the safest means to guarantee the execution of obligations. The definition of a mortgage is given in the article 560 of the Albanian Civil Code. A mortgage is a defined as concrete right placed on the wealth of a debtor or of a third party, on behalf of the creditor, in order to accomplish an obligation. Nonetheless, despite this initial definition seems to superficially imply that any wealth of the debtor or of a third party can be placed as a mortgage, this is not true because according to the article 561 of the Civil Code, the wealth or properties that can be used as mortgage are the following: Immobile property; Usufructes of these objects (of immobile property apart from the legal usufruct of the parents, as well as other emphiteotic rights over these objects. In any case, the person who places a mortgage on a property must be the owner or when this person is a third party, consent must be given so that a mortgage can be placed on a property to guarantee the accomplishment of obligations on behalf of the debtor. A mortgage can be placed on properties that are already existing at the time of the contract or properties that are about to exist in the future.

  19. An improved current control scheme for grid-connected DG unit based distribution system harmonic compensation

    DEFF Research Database (Denmark)

    He, Jinwei; Wei Li, Yun; Wang, Xiongfei

    2013-01-01

    In order to utilize DG unit interfacing converters to actively compensate distribution system harmonics, this paper proposes an enhanced current control approach. It seamlessly integrates system harmonic mitigation capabilities with the primary DG power generation function. As the proposed current...... controller has two well decoupled control branches to independently control fundamental and harmonic DG currents, phase-locked loops (PLL) and system harmonic component extractions can be avoided during system harmonic compensation. Moreover, a closed-loop power control scheme is also employed to derive...... the fundamental current reference. The proposed power control scheme effectively eliminates the impacts of steady-state fundamental current tracking errors in the DG units. Thus, an accurate power control is realized even when the harmonic compensation functions are activated. Experimental results from a single...

  20. Bilocal current densities and mean trajectories in a Young interferometer with two Gaussian slits and two detectors

    Energy Technology Data Exchange (ETDEWEB)

    Withers, L. P., E-mail: lpwithers@mitre.org [School of Physics, Astronomy, and Computational Science, George Mason University, Fairfax, Virginia 22030-4444 (United States); Narducci, F. A., E-mail: francesco.narducci@navy.mil [Naval Air Systems Command, Patuxent River, Maryland 20670 (United States)

    2015-06-15

    The recent single-photon double-slit experiment of Steinberg et al., based on a weak measurement method proposed by Wiseman, showed that, by encoding the photon’s transverse momentum behind the slits into its polarization state, the momentum profile can subsequently be measured on average, from a difference of the separated fringe intensities for the two circular polarization components. They then integrated the measured average velocity field, to obtain the average trajectories of the photons enroute to the detector array. In this paper, we propose a modification of their experiment, to demonstrate that the average particle velocities and trajectories change when the mode of detection changes. The proposed experiment replaces a single detector by a pair of detectors with a given spacing between them. The pair of detectors is configured so that it is impossible to distinguish which detector received the particle. The pair of detectors is then analogous to the simple pair of slits, in that it is impossible to distinguish which slit the particle passed through. To establish the paradoxical outcome of the modified experiment, the theory and explicit three-dimensional formulas are developed for the bilocal probability and current densities, and for the average velocity field and trajectories as the particle wavefunction propagates in the volume of space behind the Gaussian slits. Examples of these predicted results are plotted. Implementation details of the proposed experiment are discussed.

  1. Smart Control of Air Climatization System in Function on the Values of Mean Local Radiant Temperature

    Directory of Open Access Journals (Sweden)

    Giuseppe Cannistraro

    2015-08-01

    Full Text Available The hygrothermal comfort indoor conditions are defined as: those environmental conditions in which an individual exposed, expresses a state of satisfaction. These conditions cannot always be achieved anywhere in an optimal way and economically; in some cases they can be obtained only in work environments specific areas. This could be explained because of air conditioning systems designing is generally performed both on the basis of the fundamental parameters’ average values, such as temperature, velocity and relative humidity (Ta, va e φa and derived parameters such as operating temperature and mean radiant one (Top eTmr. However, in some specific cases - large open-spaces or in case of radiating surfaces - the descriptors defining indoor comfort conditions, based on average values, do not provide the optimum values required during the air conditioning systems design phase. This is largely due to the variability of real environmental parameters values compared to the average ones taken as input in the calculation. The results obtained in previous scientific papers on the thermal comfort have been the driving element of this work. It offers a simple, original and clever way of thinking about the new domotic systems for air conditioning, based on the “local mean radiant temperature.” This is a very important parameter when one wants to analyze comfort in environments characterized by the presence of radiating surfaces, as will be seen hereinafter. In order to take into account the effects of radiative exchanges in the open-space workplace, where any occupant may find themselves in different temperature and humidity conditions, this paper proposes an action on the domotic climate control, with ducts and vents air distribution placed in different zones. Comparisons were performed between the parameters values representing the punctual thermal comfort, with the Predicted Mean Vote PMV, in an environment marked by radiating surfaces (i

  2. Recent Improvements to the Control of the CTF3 High-Current Drive Beam

    CERN Document Server

    Constance, B; Gamba, D; Skowronski, P K

    2013-01-01

    In order to demonstrate the feasibility of the CLIC multiTeV linear collider option, the drive beam complex at the CLIC Test Facility (CTF3) at CERN is providing highcurrent electron pulses for a number of related experiments. By means of a system of electron pulse compression and bunch frequency multiplication, a fully loaded, 120 MeV linac is used to generate 140 ns electron pulses of around 28 Amperes. Subsequent deceleration of this high-current drive beam demonstrates principles behind the CLIC acceleration scheme, and produces 12 GHz RF power for experimental purposes. As the facility has progressed toward routine operation, a number of studies aimed at improving the drive beam performance have been carried out. Additional feedbacks, automated steering programs, and improved control of optics and dispersion have contributed to a more stable, reproducible drive beam with consequent benefits for the experiments.

  3. New Gain Controllable Resistor-less Current-mode First Order Allpass Filter and its Application

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-04-01

    Full Text Available New first order allpass filter (APF in current mode, constructed from 2 CCCCTAs and grounded capacitor, is presented. The current gain and phase shift can be electronically /orthogonally controlled. Low input and high output impedances are achieved which make the circuit to be easily cascaded to the current-mode circuit without additional current buffers. The operation of the proposed filter has been verified through simulation results which confirm the theoretical analysis. The application example as current-mode quadrature oscillator with non-interactive current control for both of oscillation condition and oscillation frequency is included to show the usability of the proposed filter.

  4. Measurement and simulation of ionic current as a means of quantifying effects of therapeutic millimeter wave radiation

    Science.gov (United States)

    Slovinsky, William Stanley

    A "millimeter wave" (MMW) is an electromagnetic oscillation with a wavelength between 1 and 10 mm, and a corresponding frequency of 30 to 300 GHz. In the spectrum of electromagnetic radiation, this band falls above the frequencies of radio waves and microwaves, and below that of infrared radiation. Since the 1950s, frequencies in this regime have been used for short range communications and beginning in the 1970s, a form of therapy known as "millimeter wave therapy" (MWT) , or microwave resonance therapy, in some publications. This form of therapy has been widely used in the republics of the former Soviet Union (FSU). As of 1995, it is estimated that more than one thousand medical centers in the FSU have performed MWT and more than three million patients have received this method of treatment. Despite the abundant use of this form of medicine, very little is known about the mechanisms by which it works. Early accounts of use are limited to Soviet government documents, largely unavailable to the scientific public, and limited translations and oral accounts from FSU scientists and literature reviews . This anecdotal body of evidence lacks the scrutiny of peer-reviewed journal publications. In order to gain more widespread acceptance in Western medicine, the pathway through which this regime of the electromagnetic radiation spectrum affects the human body must be rigorously mapped and quantified. Despite the anecdotal nature of a large portion of the existing research on biological MMW effects, a common link is the idea of an interaction occurring at the skin level, which is transduced into a signal used at a remote location in the body. This study explores a possible mechanism for the generation of this signal. The effects of therapeutic frequency MMW on the ionic currents through two different types of ion transport channels were studied, and the results are discussed with emphasis on how they relate to possible changes in nerve signals used by the body for

  5. Investigating onychophoran gas exchange and water balance as a means to inform current controversies in arthropod physiology.

    Science.gov (United States)

    Clusella-Trullas, Susana; Chown, Steven L

    2008-10-01

    Several controversies currently dominate the fields of arthropod metabolic rate, gas exchange and water balance, including the extent to which modulation of gas exchange reduces water loss, the origins of discontinuous gas exchange, the relationship between metabolic rate and life-history strategies, and the causes of Palaeozoic gigantism. In all of these areas, repeated calls have been made for the investigation of groups that might most inform the debates, especially of taxa in key phylogenetic positions. Here we respond to this call by investigating metabolic rate, respiratory water loss and critical oxygen partial pressure (Pc) in the onychophoran Peripatopsis capensis, a member of a group basal to the arthropods, and by synthesizing the available data on the Onychophora. The rate of carbon dioxide release (VCO2) at 20 degrees C in P. capensis is 0.043 ml CO2 h(-1), in keeping with other onychophoran species; suggesting that low metabolic rates in some arthropod groups are derived. Continuous gas exchange suggests that more complex gas exchange patterns are also derived. Total water loss in P. capensis is 57 mg H2O h(-1) at 20 degrees C, similar to modern estimates for another onychophoran species. High relative respiratory water loss rates ( approximately 34%; estimated using a regression technique) suggest that the basal condition in arthropods may be a high respiratory water loss rate. Relatively high Pc values (5-10% O2) suggest that substantial safety margins in insects are also a derived condition. Curling behaviour in P. capensis appears to be a strategy to lower energetic costs when resting, and the concomitant depression of water loss is a proximate consequence of this behaviour.

  6. Multi-bottle, no compressor, mean pressure control system for a Stirling engine

    Science.gov (United States)

    Corey, John A.

    1990-01-01

    The invention relates to an apparatus for mean pressure control of a Stirling engine without the need for a compressor. The invention includes a multi-tank system in which there is at least one high pressure level tank and one low pressure level tank wherein gas flows through a maximum pressure and supply line from the engine to the high pressure tank when a first valve is opened until the maximum pressure of the engine drops below that of the high pressure tank opening an inlet regulator to permit gas flow from the engine to the low pressure tank. When gas flows toward the engine it flows through the minimum pressure supply line 2 when a second valve is opened from the low pressure tank until the tank reaches the engine's minimum pressure level at which time the outlet regulator opens permitting gas to be supplied from the high pressure tank to the engine. Check valves between the two tanks prevent any backflow of gas from occurring.

  7. Improvements and standardization of communication means for control room personnel in nuclear power plants

    International Nuclear Information System (INIS)

    Preuss, W.; Eggerdinger, C.; Sieber, R.

    1982-01-01

    This report describes the findings of an investigation into selected communication means for control room personnel in nuclear power stations. The study can be seen as a contribution to the systematic analysis of major problem areas which were identified in the general study 'Human factors in the nuclear power plant'. The subjects under investigation were the 'Shift book', 'Simulation book', and 'Technical and organisational changes and their records'. It was intended to analyse both the communication, processes and the associated written documentation in order to determine areas for potential improvement and possibilities for standardization. Information was obtained by interviewing shift members and their supervisors, by general observation, and by compilation and evaluation of the extensive dokumentation. Assessment criteria were developed on a scientific basis and in the course of the investigation, in particular from ergonomic findings, as well as from standards and regulations and comparison between the plants. General practical suggestions were developed for the improvement of the communication forms and the formal design of the documents and their contents. The transfer of the recommendations to practical use in the plants presupposes the consideration of plant-specific frames of reference. The report includes a compilation and listing of suggestions for improvement in topical subdivisions. (orig.) [de

  8. Attributing Meanings to Representations of Data: The Case of Statistical Process Control

    Science.gov (United States)

    Hoyles, Celia; Bakker, Arthur; Kent, Phillip; Noss, Richard

    2007-01-01

    This article is concerned with the meanings that employees in industry attribute to representations of data and the contingencies of these meanings in context. Our primary concern is to more precisely characterize how the context of the industrial process is constitutive of the meaning of graphs of data derived from this process. We draw on data…

  9. Disturbance estimator based predictive current control of grid-connected inverters

    OpenAIRE

    Al-Khafaji, Ahmed Samawi Ghthwan

    2013-01-01

    ABSTRACT: The work presented in my thesis considers one of the modern discrete-time control approaches based on digital signal processing methods, that have been developed to improve the performance control of grid-connected three-phase inverters. Disturbance estimator based predictive current control of grid-connected inverters is proposed. For inverter modeling with respect to the design of current controllers, we choose the d-q synchronous reference frame to make it easier to understand an...

  10. Historical Overview, Current Status, and Future Trends in Human-Computer Interfaces for Process Control

    International Nuclear Information System (INIS)

    Owre, Fridtjov

    2003-01-01

    Approximately 25 yr ago, the first computer-based process control systems, including computer-generated displays, appeared. It is remarkable how slowly the human-computer interfaces (HCI's) of such systems have developed over the years. The display design approach in those early days had its roots in the topology of the process. Usually, the information came from the piping and instrumentation diagrams. Later, some important additional functions were added to the basic system, such as alarm and trend displays. Today, these functions are still the basic ones, and the end-user displays have not changed much except for improved display quality in terms of colors, font types and sizes, resolution, and object shapes, resulting from improved display hardware.Today, there are two schools of display design competing for supremacy in the process control segment of the HCI community. One can be characterized by extension and integration of current practice, while the other is more revolutionary.The extension of the current practice approach can be described in terms of added system functionality and integration. This means that important functions for the plant operator - such as signal validation, plant overview information, safety parameter displays, procedures, prediction of future states, and plant performance optimization - are added to the basic functions and integrated in a total unified HCI for the plant operator.The revolutionary approach, however, takes as its starting point the design process itself. The functioning of the plant is described in terms of the plant goals and subgoals, as well as the means available to reach these goals. Then, displays are designed representing this functional structure - in clear contrast to the earlier plant topology representation. Depending on the design approach used, the corresponding displays have various designations, e.g., function-oriented, task-oriented, or ecological displays.This paper gives a historical overview of past

  11. Attention shaping as a means to improve emotion perception deficits in outpatients with schizophrenia and impaired controls.

    Science.gov (United States)

    Combs, Dennis R; Chapman, Dustin; Waguspack, Jace; Basso, Michael R; Penn, David L

    2011-04-01

    Deficits in emotion perception are common in people with schizophrenia and current research has focused on improving these deficits. In our previous research, we demonstrated that directing attention to salient facial features via attention shaping can improve these deficits among inpatients. In this study, we examined the efficacy of an enhanced attention shaping program that contains 192 emotional expressions from which 25 are randomly presented for training. We extended our previous work by using repeated administrations of the shaping intervention and testing its effect in outpatients with schizophrenia and impaired controls. Fifteen participants with schizophrenia and fourteen college student controls with emotion perception deficits were randomly assigned to 1, 3 or 5 sessions of attention shaping. Participants completed 2 outcome measures of emotion perception, the FEIT and BLERT, not presented during the training, and underwent eye tracking at pre and post-tests. All conditions and groups improved, but the largest improvements on the BLERT and FEIT were found for persons assigned to the 5 session condition. Performance on the shaping program was positively correlated with the two outcome measures of emotion perception. There was less support for changes in visual scanning of faces as there was a relative reduction in total scanning time from pre-test to post-test. Results are interpreted in terms of the efficacy of attention shaping as a means to improve emotion perception deficits. Copyright © 2010 Elsevier B.V. All rights reserved.

  12. Control of epileptic seizures in WAG/Rij rats by means of brain-computer interface

    Science.gov (United States)

    Makarov, Vladimir V.; Maksimenko, Vladimir A.; van Luijtelaar, Gilles; Lüttjohann, Annika; Hramov, Alexander E.

    2018-02-01

    The main issue of epileptology is the elimination of epileptic events. This can be achieved by a system that predicts the emergence of seizures in conjunction with a system that interferes with the process that leads to the onset of seizure. The prediction of seizures remains, for the present, unresolved in the absence epilepsy, due to the sudden onset of seizures. We developed an algorithm for predicting seizures in real time, evaluated it and implemented it into an online closed-loop brain stimulation system designed to prevent typical for the absence of epilepsy of spike waves (SWD) in the genetic rat model. The algorithm correctly predicts more than 85% of the seizures and the rest were successfully detected. Unlike the old beliefs that SWDs are unpredictable, current results show that they can be predicted and that the development of systems for predicting and preventing closed-loop capture is a feasible step on the way to intervention to achieve control and freedom from epileptic seizures.

  13. Taxonomy of Means and Ends in Aquaculture Production—Part 2: The Technical Solutions of Controlling Solids, Dissolved Gasses and pH

    Directory of Open Access Journals (Sweden)

    Bjorgvin Vilbergsson

    2016-09-01

    Full Text Available In engineering design, knowing the relationship between the means (technique and the end (desired function or outcome is essential. The means in Aquaculture are technical solutions like airlifts that are used to achive desired functionality (an end like controlling dissolved gasses. In previous work, the authors identified possible functions by viewing aquaculture production systems as transformation processes in which inputs are transformed by treatment techniques (means and produce outputs (ends. The current work creates an overview of technical solutions of treatment functions for both design and research purposes. A comprehensive literature review of all areas of technical solutions is identified and categorized into a visual taxonomy of the treatment functions for controlling solids, controlling dissolved gasses and controlling pH alkalinity and hardness. This article is the second in a sequence of four and partly presents the treatments functions in the taxonomy. The other articles in this series present complementary aspects of this research: Part 1, A transformational view on aquaculture and functions divided into input, treatment and output functions; Part 2, The current taxonomy paper; Part 3, The second part of the taxonomy; and Part 4, Mapping of the means (techniques for multiple treatment functions.

  14. A Decentralized Current-Sharing Controller Endows Fast Transient Response to Parallel DC-DC Converters

    DEFF Research Database (Denmark)

    Wang, Haojie; Han, Minxiao; Han, Renke

    2018-01-01

    This paper proposes a decentralized current-sharing control strategy to endow fast transient response to paralleled DC-DC converters systems, such as DC microgrids or distributed power systems. The proposed controller consist of two main control loops: an external voltage droop control for current......-sharing proposes and an internal current loop. The external droop control loop is designed as a voltage loop with embedded virtual impedance, which avoids the use of a slow voltage loop and a separate extra virtual impedance loop that may limit the system bandwidth. The internal current loop, thanks...... and the proposed embedded-virtual-impedance based I-V droop. In order to compare the dynamic response performances between two droop controllers, their state-space models have been developed and analyzed in this paper. The results show that the dynamic response of the I-V droop control is faster than...

  15. Justification and choice of hardware for automatic control system by technical means at the garage consumer cooperative

    Directory of Open Access Journals (Sweden)

    Krasnykh V.Yu.

    2017-06-01

    Full Text Available the article describes the main system requirements of software of finished products for implementation of an automatic control system by technical means at the garage consumer cooperative.

  16. Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    -sequence current components is becoming necessary for achieving new capabilities like the reactive power injection during a grid fault. This paper deals with a fundamental issue in this topic, i.e., the performance of the current controller. Classical dq controllers, which are extensively used in industrial...

  17. An Examination of Meaning in Life, Satisfaction with Life, Self-Concept and Locus of Control among Teachers

    Science.gov (United States)

    Tas, Ibrahim; Iskender, Murat

    2018-01-01

    The aim of this study is to examine meaning in life, satisfaction with life, self-concept and locus of control among teachers by several variables. The research group was composed of 363 teachers (114 [40%] women, 219 [60%] men) working in several districts of Istanbul. The data were collected with Meaning in Life Scale (MLS), Satisfaction with…

  18. Design of Nonlinear Robust Rotor Current Controller for DFIG Based on Terminal Sliding Mode Control and Extended State Observer

    Directory of Open Access Journals (Sweden)

    Guowei Cai

    2014-01-01

    Full Text Available As to strong nonlinearity of doubly fed induction generators (DFIG and uncertainty of its model, a novel rotor current controller with nonlinearity and robustness is proposed to enhance fault ride-though (FRT capacities of grid-connected DFIG. Firstly, the model error, external disturbances, and the uncertain factors were estimated by constructing extended state observer (ESO so as to achieve linearization model, which is compensated dynamically from nonlinear model. And then rotor current controller of DFIG is designed by using terminal sliding mode variable structure control theory (TSMC. The controller has superior dynamic performance and strong robustness. The simulation results show that the proposed control approach is effective.

  19. All-electric-controlled spin current switching in single-molecule magnet-tunnel junctions

    Science.gov (United States)

    Zhang, Zheng-Zhong; Shen, Rui; Sheng, Li; Wang, Rui-Qiang; Wang, Bai-Gen; Xing, Ding-Yu

    2011-04-01

    A single-molecule magnet (SMM) coupled to two normal metallic electrodes can both switch spin-up and spin-down electronic currents within two different windows of SMM gate voltage. Such spin current switching in the SMM tunnel junction arises from spin-selected single electron resonant tunneling via the lowest unoccupied molecular orbit of the SMM. Since it is not magnetically controlled but all-electrically controlled, the proposed spin current switching effect may have potential applications in future spintronics.

  20. Current Mode Control for LLC Series Resonant DC-to-DC Converters

    Directory of Open Access Journals (Sweden)

    Jinhaeng Jang

    2015-06-01

    Full Text Available Conventional voltage mode control only offers limited performance for LLC series resonant DC-to-DC converters experiencing wide variations in operational conditions. When the existing voltage mode control is employed, the closed-loop performance of the converter is directly affected by unavoidable changes in power stage dynamics. Thus, a specific control design optimized at one particular operating point could become unacceptable when the operational condition is varied. This paper presents a new current mode control scheme which could consistently provide good closed-loop performance for LLC resonant converters for the entire operational range. The proposed control scheme employs an additional feedback from the current of the resonant tank network to overcome the limitation of the existing voltage mode control. The superiority of the proposed current mode control over the conventional voltage mode control is verified using an experimental 150 W LLC series resonant DC-to-DC converter.

  1. Mindful decision making and inhibitory control training as complementary means to decrease snack consumption.

    Science.gov (United States)

    Forman, Evan M; Shaw, Jena A; Goldstein, Stephanie P; Butryn, Meghan L; Martin, Lindsay M; Meiran, Nachshon; Crosby, Ross D; Manasse, Stephanie M

    2016-08-01

    Obesity is largely attributable to excess caloric intake, in particular from "junk" foods, including salty snack foods. Evidence suggests that neurobiological preferences to consume highly hedonic foods translate (via implicit processes) into poor eating choices, unless overturned by inhibitory mechanisms or interrupted by explicit processes. The primary aim of the current study was to test the independent and combinatory effects of a computerized inhibitory control training (ICT) and a mindful decision-making training (MDT) designed to facilitate de-automatization. We randomized 119 habitual salty snack food eaters to one of four short, training conditions: MDT, ICT, both MDT and ICT, or neither (i.e., psychoeducation). For 7 days prior to the intervention and 7 days following the intervention, participants reported on their salty snack food consumption 2 times per day, on 3 portions of their days, using a smartphone-based ecological momentary assessment system. Susceptibility to emotional eating cues was measured at baseline. Results indicated that the effect of MDT was consistent across levels of trait emotional eating, whereas the benefit of ICT was apparent only at lower levels of emotional eating. No synergistic effect of MDT and ICT was detected. These results provide qualified support for the efficacy of both types of training for decreasing hedonically-motivated eating. Moderation effects suggest that those who eat snack foods for reasons unconnected to affective experiences (i.e., lower in emotional eating) may derive benefit from a combination of ICT and MDT. Future research should investigate the additive benefit of de-automization training to standard weight loss interventions. Copyright © 2016 Elsevier Ltd. All rights reserved.

  2. Distributed Secondary Control for DC Microgrid Applications with Enhanced Current Sharing Accuracy

    DEFF Research Database (Denmark)

    Lu, Xiaonan; Guerrero, Josep M.; Sun, Kai

    2013-01-01

    With the consideration of line resistances in a dc microgrid, the current sharing accuracy is lowered down, since the dc output voltage cannot be exactly the same for different interfacing converters. Meanwhile, the dc bus voltage deviation is involved by using droop control. In this paper...... control diagram is accomplished and the requirement of distributed configuration in a microgrid is satisfied. The experimental validation based on a 2×2.2 kW prototype was implemented to demonstrate the proposed approach......., a distributed secondary control method is proposed. Droop control is employed as the primary control method for load current sharing. Meanwhile, the dc output voltage and current in each module is transferred to the others by the low bandwidth communication (LBC) network. Average voltage and current controllers...

  3. Prospects for steady-state tokamak reactor operation through feedback control of the current density profile

    Energy Technology Data Exchange (ETDEWEB)

    Moreau, D

    1994-12-31

    A brief overview of the most relevant experiments on current profile modifications, strong improvements with respect to the usual L-mode scaling laws and Troyon beta limit is presented, as relevant issues for most tokamaks. Practical means and scenarios for producing and maintaining the optimum current profiles in the various phases of the thermonuclear discharge (profile formation, current ramp-up, burn phase) are proposed. (author). 34 refs., 3 figs.

  4. Rectifier Current Control for an LLC Resonant Converter Based on a Simplified Linearized Model

    OpenAIRE

    Zhijian Fang; Junhua Wang; Shanxu Duan; Liangle Xiao; Guozheng Hu; Qisheng Liu

    2018-01-01

    In this paper, a rectifier current control for an LLC resonant converter is proposed, based on a simplified, two-order, linearized model that adds a rectifier current feedback inner loop to improve dynamic performance. Compared to the traditional large-signal model with seven resonant states, this paper utilizes a rectifier current state to represent the characteristics of the resonant states, simplifying the LLC resonant model from seven orders to two orders. Then, the rectifier current feed...

  5. Realization of Electronically Controllable Current-mode Square-rooting Circuit Based on MO-CFTA

    OpenAIRE

    P. Silapan; C. Chanapromma; T. Worachak

    2011-01-01

    This article proposes a current-mode square-rooting circuit using current follower transconductance amplifier (CTFA). The amplitude of the output current can be electronically controlled via input bias current with wide input dynamic range. The proposed circuit consists of only single CFTA. Without any matching conditions and external passive elements, the circuit is then appropriate for an IC architecture. The magnitude of the output signal is temperature-insensitive. Th...

  6. Autotuning of PID controller by means of human machine interface device

    Directory of Open Access Journals (Sweden)

    Michał Awtoniuk

    2017-06-01

    Full Text Available More and more control systems are based on industry microprocessors like PLC controllers (Programmable Logic Controller. The most commonly used control algorithm is PID (Proportional-Integral-Derivative algorithm. Autotuning procedure is not available in every PLC. These controllers are typically used in cooperation with HMI (Human Machine Interface devices. In the study two procedures of autotuning of the PID controller were implemented in the HMI device: step method and relay method. Six tuning rules for step methods and one for relay method were chosen. The autotuning procedures on simulated controlled object and PLC controller without build-in autotuning were tested. The object of control was first order system plus time delay.

  7. Real-time control of the current density and pressure profiles in Jet

    International Nuclear Information System (INIS)

    Mazon, D.; Moreau, D.; Litaudon, X.; Joffrin, E.; Laborde, L.; Zabeo, L.; Crisanti, F.; Riva, M.; Felton, R.; Murari, A.; Tala, T.

    2003-01-01

    In order to ultimately control internal transport barriers during advanced operation scenarios, new algorithms using a truncated singular value decomposition of a linearized model operator have been implemented in the JET real-time controller, with the potentiality of retaining the distributed nature of plasma parameter profiles. First experiments using the simplest, lumped-parameter, version of this technique have been dedicated to the feedback control of the current density profile in a negative shear plasma using three heating and current drive actuators, namely neutral beam injection (NBI), ion cyclotron resonant frequency heating (ICRH) and lower hybrid current drive (LHCD). Successful control of the safety factor profile has been achieved on the time scale of the current redistribution time, first during an extended preheat phase with only LHCD as actuator and, then, in quasi steady-state conditions during the main heating phase of a discharge, using the three heating and current drive actuators

  8. Feedback control of current drive by using hybrid wave in tokamaks

    International Nuclear Information System (INIS)

    Wijnands, T.J.; CEA Centre d'Etudes de Cadarache, 13 - Saint-Paul-lez-Durance

    1997-03-01

    This work is focussed on an important and recent development in present day Controlled Nuclear Fusion Research and Tokamaks. The aim is to optimise the energy confinement for a certain magnetic configuration by adapting the radial distribution of the current. Of particular interest are feedback control scenarios with stationary modifications of the current profile using current, driven by Lower Hybrid waves. A new feedback control system has been developed for Tore Supra and has made a large number of new operation scenarios possible. In one of the experiments described here, there is no energy exchange between the poloidal field system and the plasma, the current is controlled by the power of the Lower Hybrid waves while the launched wave spectrum is used to optimise the current profile shape and the energy confinement. (author)

  9. Enhancing the Frequency Adaptability of Periodic Current Controllers for Grid-Connected Power Converters

    DEFF Research Database (Denmark)

    Yang, Yongheng; Zhou, Keliang; Blaabjerg, Frede

    2015-01-01

    It is mandatory for grid-connected power converters to synchronize the feed-in currents with the grid. Moreover, the power converters should produce feed-in currents with low total harmonic distortions according to the demands, by employing advanced current controllers, e.g., Proportional Resonant...... deviations. Experiments on a single-phase grid-connected inverter system are presented, which have verified the proposals and also the effectiveness of the frequency adaptive current controllers....... (PR) and Repetitive Controllers (RC). The synchronization is actually to detect the instantaneous grid information (e.g., frequency and phase of the grid voltage) for the current control, which is commonly performed by a Phase-Locked-Loop (PLL) system. As a consequence, harmonics and deviations...

  10. Simple DCM or CRM analog peak current controller for HV capacitor charge-discharge applications

    DEFF Research Database (Denmark)

    Trintis, Ionut; Dimopoulos, Emmanouil; Munk-Nielsen, Stig

    2013-01-01

    This paper presents a simple analog current controller suitable for buck and boost converter topologies. The controller operates in DCM or CRM, depending on the setup. The experimental results are presented to validate the proposed controller functionality for a high voltage capacitor charge...

  11. Real time control of EC heating & current drive systems on TCV

    NARCIS (Netherlands)

    Paley, J.I.; Felici, F.; Curchod, L.; Coda, S.; Goodman, T.P.

    2009-01-01

    The ability to control, in real time, the electron cyclotron heating & current drive systems for the control of MHD instabilities is particularly important for large tokamaks operating at high performance. Several algorithms have been developed and tested on TCV to explore possible control

  12. A unified grid current control for grid-interactive DG inverters in microgrids

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Loh, Poh Chiang; Blaabjerg, Frede

    2015-01-01

    This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittan...... locus analyses in the discrete z-domain are performed for elaborating the controller design. Simulations and experimental results demonstrate the performances of the proposed approach.......This paper proposes a unified grid current control for grid-interactive distributed generation inverters. In the approach, the grid-side current, instead of inverter-side current, is controlled as an inner loop, while the filter capacitor voltage is indirectly regulated through a virtual admittance...... in the outer loop. It, therefore, provides several superior features over traditional control schemes: 1) high-quality grid current in the grid-connected mode, 2) inherent derivative-less virtual output impedance control, and 3) the unified active damping for both grid-connected and islanded operations. Root...

  13. Modeling and control of the output current of a Reformed Methanol Fuel Cell system

    DEFF Research Database (Denmark)

    Justesen, Kristian Kjær; Andreasen, Søren Juhl; Pasupathi, Sivakumar

    2015-01-01

    In this work, a dynamic Matlab SIMULINK model of the relationship between the fuel cell current set point of a Reformed Methanol Fuel Cell system and the output current of the system is developed. The model contains an estimated fuel cell model, based on a polarization curve and assumed first order...... dynamics, as well as a battery model based on an equivalent circuit model and a balance of plant power consumption model. The models are tuned with experimental data and verified using a verification data set. The model is used to develop an output current controller which can control the charge current...... of the battery. The controller is a PI controller with feedforward and anti-windup. The performance of the controller is tested and verified on the physical system....

  14. Design of laser diode driver with constant current and temperature control system

    Science.gov (United States)

    Wang, Ming-cai; Yang, Kai-yong; Wang, Zhi-guo; Fan, Zhen-fang

    2017-10-01

    A laser Diode (LD) driver with constant current and temperature control system is designed according to the LD working characteristics. We deeply researched the protection circuit and temperature control circuit based on thermos-electric cooler(TEC) cooling circuit and PID algorithm. The driver could realize constant current output and achieve stable temperature control of LD. Real-time feedback control method was adopted in the temperature control system to make LD work on its best temperature point. The output power variety and output wavelength shift of LD caused by current and temperature instability were decreased. Furthermore, the driving current and working temperature is adjustable according to specific requirements. The experiment result showed that the developed LD driver meets the characteristics of LD.

  15. Complex state variable- and disturbance observer-based current controllers for AC drives

    DEFF Research Database (Denmark)

    Dal, Mehmet; Teodorescu, Remus; Blaabjerg, Frede

    2013-01-01

    In vector-controlled AC drives, the design of current controller is usually based on a machine model defined in synchronous frame coordinate, where the drive performance may be degraded by both the variation of the machine parameters and the cross-coupling between the d- and q-axes components...... of the stator current. In order to improve the current control performance an alternative current control strategy was proposed previously aiming to avoid the undesired cross-coupling and non-linearities between the state variables. These effects are assumed as disturbances arisen in the closed-loop path...... of the parameter and the cross-coupling effect. Moreover, it provides a better performance, smooth and low noisy operation with respect to the complex variable controller....

  16. The double meaning of control: three-way interactions between internal resources, job control, and stressors at work.

    Science.gov (United States)

    Meier, Laurenz L; Semmer, Norbert K; Elfering, Achim; Jacobshagen, Nicola

    2008-07-01

    The Job Demand-Control model postulates that job control attenuates the effects of job demands on health and well-being. Support for this interactive effect is rather weak. Conceivably, it holds only when there is a match between job control and individual characteristics that relate to exercising control options, such as locus of control, or self-efficacy. This three-way interaction was tested in a sample of 96 service employees, with affective strain and musculoskeletal pain as dependent variables. As hypothesized, job control attenuated the effects of stressors only for people with an internal locus of control. For people with an external locus of control, job control actually predicted poorer well-being and health as stressors increased. For self-efficacy, the corresponding three-way interaction was significant with regard to affective strain. Copyright (c) 2008 APA, all rights reserved.

  17. Performance assessment of a dynamic current allocator for the JET eXtreme Shape Controller

    International Nuclear Information System (INIS)

    Varano, G.; Ambrosino, G.; Tommasi, G.De; Galeani, S.; Pironti, A.; Zaccarian, L.

    2011-01-01

    This paper reports on a recently proposed dynamic allocation technique that can be effectively adopted to handle the current saturations of the Poloidal Field coils with the eXtreme Shape Controller. The proposed approach allows to automatically relax the plasma shape regulation when the reference shape requires current levels out of the available ranges, finding in real-time an optimal trade-off between shape control precision and currents saturation avoidance. In this paper the results attained during preliminary analysis are presented, showing the advantage arising from the use of the dynamic allocator, versus the bare use of the eXtreme Shape Controller.

  18. Control Strategies for Islanded Microgrid using Enhanced Hierarchical Control Structure with Multiple Current-Loop Damping Schemes

    DEFF Research Database (Denmark)

    Han, Yang; Shen, Pan; Zhao, Xin

    2017-01-01

    In this paper, the modeling, controller design, and stability analysis of the islanded microgrid (MG) using enhanced hierarchical control structure with multiple current loop damping schemes is proposed. The islanded MG is consisted of the parallel-connected voltage source inverters using LCL...... output filters, and the proposed control structure includes: the primary control with additional phase-shift loop, the secondary control for voltage amplitude and frequency restoration, the virtual impedance loops which contains virtual positive- and negative-sequence impedance loops at fundamental...... frequency, and virtual variable harmonic impedance loop at harmonic frequencies, and the inner voltage and current loop controllers. A small-signal model for the primary and secondary controls with additional phase-shift loop is presented, which shows an over-damped feature from eigenvalue analysis...

  19. Control of tokamak plasma current and equilibrium with hybrid poloidal field coils

    International Nuclear Information System (INIS)

    Shimada, Ryuichi

    1982-01-01

    A control method with hybrid poloidal field system is considered, which comprehensively implements the control of plasma equilibrium and plasma current, those have been treated independently in Tokamak divices. Tokamak equilibrium requires the condition that the magnetic flux function value on plasma surface must be constant. From this, the current to be supplied to each coil is determined. Therefore, each coil current is the resultant of the component related to plasma current excitation and the component required for holding equilibrium. Here, it is intended to show a method by which the current to be supplied to each coil can easily be calculated by the introduction of hybrid control matrix. The text first considers the equilibrium of axi-symmetrical plasma and the equilibrium magnetic field outside plasma, next describes the determination of current using the above hybrid control matrix, and indicates an example of controlling Tokamak plasma current and equilibrium by the hybrid poloidal field coils. It also shows that the excitation of plasma current and the maintenance of plasma equilibrium can basically be available with a single power supply by the appropriate selection of the number of turns of each coil. These considerations determine the basic system configuration as well as decrease the installed capacity of power source for the poloidal field of a Tokamak fusion reactor. Finally, the actual configuration of the power source for hybrid poloidal field coils is shown for the above system. (Wakatsuki, Y.)

  20. A novel harmonic current sharing control strategy for parallel-connected inverters

    DEFF Research Database (Denmark)

    Guan, Yajuan; Guerrero, Josep M.; Savaghebi, Mehdi

    2017-01-01

    A novel control strategy which enables proportional linear and nonlinear loads sharing among paralleled inverters and voltage harmonic suppression is proposed in this paper. The proposed method is based on the autonomous currents sharing controller (ACSC) instead of conventional power droop control...... to provide fast transient response, decoupling control and large stability margin. The current components at different sequences and orders are decomposed by a multi-second-order generalized integrator-based frequency locked loop (MSOGI-FLL). A harmonic-orthogonal-virtual-resistances controller (HOVR......) is used to proportionally share current components at different sequences and orders independently among the paralleled inverters. Proportional resonance controllers tuned at selected frequencies are used to suppress voltage harmonics. Simulations based on two 2.2 kW paralleled three-phase inverters...

  1. Balancing Power Output and Structural Fatigue of Wave Energy Converters by Means of Control Strategies

    Directory of Open Access Journals (Sweden)

    Francesco Ferri

    2014-04-01

    Full Text Available In order to reduce the cost of electricity produced by wave energy converters (WECs, the benefit of selling electricity as well as the investment costs of the structure has to be considered. This paper presents a methodology for assessing the control strategy for a WEC with respect to both energy output and structural fatigue loads. Different active and passive control strategies are implemented (proportional (P controller, proportional-integral (PI controller, proportional-integral-derivative with memory compensation (PID controller, model predictive control (MPC and maximum energy controller (MEC, and load time-series resulting from numerical simulations are used to design structural parts based on fatigue analysis using rain-flow counting, Stress-Number (SN curves and Miner’s rule. The objective of the methodology is to obtain a cost-effective WEC with a more comprehensive analysis of a WEC based on a combination of well known control strategies and standardised fatigue methods. The presented method is then applied to a particular case study, the Wavestar WEC, for a specific location in the North Sea. Results, which are based on numerical simulations, show the importance of balancing the gained power against structural fatigue. Based on a simple cost model, the PI controller is shown as a viable solution.

  2. Constant voltage and constant current control implementation for electric vehicles (evs) wireless charger

    Science.gov (United States)

    Tampubolon, Marojahan; Pamungkas, Laskar; Hsieh, Yao Ching; Chiu, Huang Jen

    2018-04-01

    This paper presents the implementation of Constant Voltage (CV) and Constant Current (CC) control for a wireless charger system. A battery charging system needs these control modes to ensure the safety of the battery and the effectiveness of the charging system. Here, the wireless charger system does not employ any post-regulator stage to control the output voltage and output current of the charger. But, it uses a variable frequency control incorporated with a conventional PI control. As a result, the size and the weight of the system are reduced. This paper discusses the brief review of the SS-WPT, control strategy and implementation of the CV and CC control. Experimental hardware with 2kW output power has been performed and tested. The results show that the proposed CV and CC control method works well with the system.

  3. Enhancing current density profile control in tokamak experiments using iterative learning control

    NARCIS (Netherlands)

    Felici, F.A.A.; Oomen, T.A.E.

    2015-01-01

    Tokamaks are toroidal devices to create and confine high-temperature plasmas, and are presently at the forefront of nuclear fusion research. Many parameters in a tokamak are feedback controlled, but some quantities that are either difficult to measure or difficult to control are still controlled by

  4. Human kinematics and event control: On-line movement registration as a means for experimental manipulation

    NARCIS (Netherlands)

    Oudejans, R.R.D.; Coolen, H.

    2003-01-01

    In human movement and sports science, manipulations of perception and action are common and often comprise the control of events, such as opening or closing liquid crystal goggles. Most of these events are externally controlled, independent of the actions of the participants. Less common, although

  5. Using Control Heuristics as a Means to Explore the Educational Potential of Robotics Kits

    Science.gov (United States)

    Gaudiello, Ilaria; Zibetti, Elisabetta

    2013-01-01

    The educational potential of robotics kits as a form of control technology will remain undervalued until meaningful observation parameters are identified to enable a better understanding of children?s control strategies. For this reason, this paper aims primarily to identify and classify the heuristics spontaneously applied by 6-10 year old…

  6. Low average blister-rust infection rates may mean high control costs

    Science.gov (United States)

    Robert Marty

    1965-01-01

    The Northeastern Forest Experiment Station, in cooperation with Federal and State forest-pest-control agencies, undertook a survey of blister-rust infection rates in the white pine region of the East during 1962 and 1963. Those engaged in blister-rust-control activities will not be surprised at the survey's results. We found that infection rates were significantly...

  7. Controlling microwave signals by means of slow and fast light effects in SOA-EA structures

    DEFF Research Database (Denmark)

    Sales, Salvador; Öhman, Filip; Capmany, José

    2007-01-01

    We present a novel scheme for the control of microwave signals in the optical domain. We propose the use of alternating amplifying and absorbing sections to implement phase control by using fast and slow light effects in semiconductors. The potential benefits from the proposed semiconductor optic...

  8. Visualization of differences across port state control regimes by means of correspondence analysis

    NARCIS (Netherlands)

    S. Knapp (Sabine); M. van de Velden (Michel)

    2007-01-01

    textabstractThis article is based on a combined dataset of 183,819 port state control (PSC) inspections from various port state control regimes around the world. In theory, there should be no differences in treatments of inspections to determine if a vessel is substandard or not no matter where the

  9. A Hierarchical Control Scheme for Reactive Power and Harmonic Current Sharing in Islanded Microgrids

    DEFF Research Database (Denmark)

    Lorzadeh, Iman; Firoozabadi, Mehdi Savaghebi; Askarian Abyaneh, Hossein

    2015-01-01

    In this paper, a hierarchical control scheme consisting of primary and secondary levels is proposed for achieving accurate reactive power and harmonic currents sharing among interface inverters of distributed generators (DGs) in islanded microgrids. Firstly, fundamental and main harmonic componen...

  10. H∞ Robust Current Control for DFIG Based Wind Turbine subject to Grid Voltage Distortions

    DEFF Research Database (Denmark)

    Wang, Yun; Wu, Qiuwei; Gong, Wenming

    2016-01-01

    This paper proposes an H∞ robust current controller for doubly fed induction generator (DFIG) based wind turbines (WTs) subject to grid voltage distortions. The controller is to mitigate the impact of the grid voltage distortions on rotor currents with DFIG parameter perturbation. The grid voltage...... distortions considered include asymmetric voltage dips and grid background harmonics. An uncertain DFIG model is developed with uncertain factors originating from distorted stator voltage, and changed generator parameters due to the flux saturation effect, the skin effect, etc. Weighting functions...... are designed to efficiently track the unbalanced current components and the 5th and 7th background harmonics. The robust stability (RS) and robust performance (RP) of the proposed controller are verified by the structured singular value µ. The performance of the H∞ robust current controller was demonstrated...

  11. THE COMPUTER SIMULATOR-CONTROLLER FOR LEARNING SIGN AND SYMBOLIC MEANS OF PHYSICS

    Directory of Open Access Journals (Sweden)

    N.I. Tikhonskaya

    2012-10-01

    Full Text Available The promising application of information technology for learning sign and symbolic means of physics is proposed and theoretically proved in this article. This direction is connected with the idea of training students the presentation of information in different forms.

  12. Missing data in clinical trials: control-based mean imputation and sensitivity analysis.

    Science.gov (United States)

    Mehrotra, Devan V; Liu, Fang; Permutt, Thomas

    2017-09-01

    In some randomized (drug versus placebo) clinical trials, the estimand of interest is the between-treatment difference in population means of a clinical endpoint that is free from the confounding effects of "rescue" medication (e.g., HbA1c change from baseline at 24 weeks that would be observed without rescue medication regardless of whether or when the assigned treatment was discontinued). In such settings, a missing data problem arises if some patients prematurely discontinue from the trial or initiate rescue medication while in the trial, the latter necessitating the discarding of post-rescue data. We caution that the commonly used mixed-effects model repeated measures analysis with the embedded missing at random assumption can deliver an exaggerated estimate of the aforementioned estimand of interest. This happens, in part, due to implicit imputation of an overly optimistic mean for "dropouts" (i.e., patients with missing endpoint data of interest) in the drug arm. We propose an alternative approach in which the missing mean for the drug arm dropouts is explicitly replaced with either the estimated mean of the entire endpoint distribution under placebo (primary analysis) or a sequence of increasingly more conservative means within a tipping point framework (sensitivity analysis); patient-level imputation is not required. A supplemental "dropout = failure" analysis is considered in which a common poor outcome is imputed for all dropouts followed by a between-treatment comparison using quantile regression. All analyses address the same estimand and can adjust for baseline covariates. Three examples and simulation results are used to support our recommendations. Copyright © 2017 John Wiley & Sons, Ltd.

  13. Double-Frame Current Control with a Multivariable PI Controller and Power Compensation for Weak Unbalanced Networks

    CERN Document Server

    Siemaszko, Daniel

    2015-06-15

    The handling of weak networks with asymmetric loads and disturbances im- plies the accurate handling of the second-harmonic component that appears in an unbalanced network. This paper proposes a classic vector control approach using a PI-based controller with superior decoupling capabilities for operation in weak networks with unbalanced phase voltages. A synchronization method for weak unbalanced networks is detailed, with dedicated dimensioning rules. The use of a double-frame controller allows a current symmetry or controlled imbalance to be forced for compensation of power oscillations by controlling the negative current sequence. This paper also serves as a useful reminder of the proper way to cancel the inherent coupling effect due to the transformation to the synchronous rotating reference frame, and of basic considerations of the relationship between switching frequency and control bandwidth.

  14. Design of Controller for Reducing In-Rush Current of Single-Phase Induction Motor

    Energy Technology Data Exchange (ETDEWEB)

    Park, Su Kang; Baek, Hyung Lae; Lee, Sang Il [Chosun University, Kwangju (Korea)

    2001-05-01

    During an AC motor's start-up accelerating period, a large amount of current is required to reach to the rating speed. This is called in-rush current. This peak in-rush current can be more than about several times the operating or steady-state current in the full load rating of the motor. In-rush current is present in both and electronic ballasts. The main area of concern is the tripping of circuit breaker and fuses which can affect electrical system components From this, we can see that the electrical power controllers will be rather concerned, since they have to supply the actual current necessary to start the motor. This paper presents a new method to reducing in-rush current and energy saving of the single-phase induction motor used in air-conditioner. It can be obtained that proposed system is low cost and small size as compared with other controller. Experiments are focused on a capacitor starting single-phase induction motor. The optimal power saving and in-rush current limiting by phase angle control are verified by experimental results. Also, auxiliary winding was controlled by electronic starting switch. (author). 10 refs., 13 figs., 2 tabs.

  15. Indirect thermal control for improved reliability of Modular Multilevel Converter by utilizing circulating current

    DEFF Research Database (Denmark)

    Dowlatabadi, Mohammadkazem Bakhshizadeh; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    semiconductor devices are comprehensively investigated. Also a novel control strategy by utilizing the circulating current is proposed to enhance the reliability performance of MMC in order to limit the amplitude of thermal cycles. It is concluded that the circulating current may change the losses and thermal...

  16. 37 CFR 1.419 - Display of currently valid control number under the Paperwork Reduction Act.

    Science.gov (United States)

    2010-07-01

    ... 37 Patents, Trademarks, and Copyrights 1 2010-07-01 2010-07-01 false Display of currently valid... UNITED STATES PATENT AND TRADEMARK OFFICE, DEPARTMENT OF COMMERCE GENERAL RULES OF PRACTICE IN PATENT CASES International Processing Provisions General Information § 1.419 Display of currently valid control...

  17. Instantaneous Project Controls: Current Status, State of the Art, Benefits, and Strategies

    Science.gov (United States)

    Abbaszadegan, Amin

    2016-01-01

    Despite advancements in construction and construction-related technology, capital project performance deviations, typically overruns, remain endemic within the capital projects industry. Currently, management is generally unaware of the current status of their projects, and thus monitoring and control of projects are not achieved effectively. In…

  18. A DC Microgrid Coordinated Control Strategy Based on Integrator Current-Sharing

    DEFF Research Database (Denmark)

    Gao, Liyuan; Liu, Yao; Ren, Huisong

    2017-01-01

    The DC microgrid has become a new trend for microgrid study with the advantages of high reliability, simple control and low losses. With regard to the drawbacks of the traditional droop control strategies, an improved DC droop control strategy based on integrator current-sharing is introduced....... In the strategy, the principle of eliminating deviation through an integrator is used, constructing the current-sharing term in order to make the power-sharing between different distributed generation (DG) units uniform and reasonable, which can reduce the circulating current between DG units. Furthermore......, at the system coordinated control level, a hierarchical/droop control strategy based on the DC bus voltage is proposed. In the strategy, the operation modes of the AC main network and micro-sources are determined through detecting the DC voltage variation, which can ensure the power balance of the DC microgrid...

  19. Study on model current predictive control method of PV grid- connected inverters systems with voltage sag

    Science.gov (United States)

    Jin, N.; Yang, F.; Shang, S. Y.; Tao, T.; Liu, J. S.

    2016-08-01

    According to the limitations of the LVRT technology of traditional photovoltaic inverter existed, this paper proposes a low voltage ride through (LVRT) control method based on model current predictive control (MCPC). This method can effectively improve the photovoltaic inverter output characteristics and response speed. The MCPC method of photovoltaic grid-connected inverter designed, the sum of the absolute value of the predictive current and the given current error is adopted as the cost function with the model predictive control method. According to the MCPC, the optimal space voltage vector is selected. Photovoltaic inverter has achieved automatically switches of priority active or reactive power control of two control modes according to the different operating states, which effectively improve the inverter capability of LVRT. The simulation and experimental results proves that the proposed method is correct and effective.

  20. Energy management in a domestic microgrid by means of model predictive controllers

    International Nuclear Information System (INIS)

    Bruni, G.; Cordiner, S.; Mulone, V.; Sinisi, V.; Spagnolo, F.

    2016-01-01

    The need to increase renewable energy sources deployment and to reduce consumption of fossil fuels has led to the diffusion of small-scale DG (Distributed Generation) systems, which may be effectively integrated in micro-grids. The role of control logic in defining microgrid performances and reliability is predominant and can be improved by using advanced control logics such as the ones based on MPC (Model Predictive Control). In a previous paper, a MPC logic, based on the use of weather forecasts to improve the performances, has been applied to the analysis of power management in a domestic micro-grid system composed by: PV (Photovoltaic panels), FC (Fuel Cells) and a battery pack; in that case, the system was not affected by real uncertainties. In this paper the same system has been considered for domestic microgrid applications. The system control logic has been implemented by assuming real weather forecast as input data. DMPC and SMPC (Deterministic and Stochastic Model Predictive Control) concepts have been applied to the system and results have been compared to both MPC and to a standard RBC (Rule Based Control) logic. The impact of forecast uncertainties has been evaluated showing the advantages of a stochastic approach. In that case, the SMPC showed encouraging performances compared to standard control logics, primarily in terms of primary energy savings and downsizing potential of the power-delivering sub-systems using programmable energy sources. - Highlights: • A Model Predictive Controller has been used to optimize the behaviour of a microgrid. • A stochastic approach has been used to model weather forecast uncertainties. • 10% savings of HVAC required energy have been demonstrated. • Savings in primary fossil energy range between 10% and 30%. • Power sub-systems using programmable sources can be consistently downsized.

  1. An attempt at MHD mode control by feedback modulation of L.H. driven current

    International Nuclear Information System (INIS)

    Parlange, F.; Vallet, J.C

    1986-01-01

    MHD activity in Tokamak discharges with lower hybrid current drive has distinct features which can be used to stabilize tearing modes. A way of reducing the m=2 tearing mode was recently proposed, consisting in driving more current at the 0 point of the islands than at the X point, by means of amplitude modulated lower hybrid waves. The way it was tested in Petula is presented here

  2. A metronome for controlling the mean velocity during the bench press exercise.

    Science.gov (United States)

    Moras, Gerard; Rodríguez-Jiménez, Sergio; Busquets, Albert; Tous-Fajardo, Julio; Pozzo, Marco; Mujika, Iñigo

    2009-05-01

    Lifting velocity may have a great impact on strength training-induced adaptations. The purpose of this study was to validate a method including a metronome and a measurement tape as inexpensive tools for the estimation of mean lifting velocity during the bench press exercise. Fifteen subjects participated in this study. After determining their one repetition maximum (1RM) load, we estimated the maximum metronome rhythm (R) that each subject could maintain in the concentric phase for loads of 40 and 60% of 1RM. To estimate R, the 3 repetitions with highest concentric power, as measured by means of a linear encoder, were selected, and their average duration was calculated and converted to lifting rhythm in beats per minute (bpm) for each subject. The range of motion was measured using a regular tape and kept constant during all exercises. Subjects were instructed to begin with the barbell at arm lengths and lower it in correspondence with the metronome beep. They subsequently performed 5 repetitions at 3 different rhythms relative to R (50, 70, and 90% R) for each training load (40 and 60% of 1RM). A linear encoder was attached to the bar and used as a criterion to measure the vertical displacement over time. For each rhythm, the mean velocity was calculated with the metronome (time) and the reference distance and compared with that recorded by the linear encoder. The SEM for velocity between both testing methods ranged from 0.02 to 0.05 m.s (coefficient of variation, 4.0-6.4%; Pearson's correlation, 0.8-0.95). The present results showed that the use of a metronome and a measurement tape may be a valid method to estimate the mean velocity of execution during the bench press exercise. This simple method could help coaches and athletes achieve their strength training goals, which are partly determined by lifting velocity.

  3. A fault-tolerant strategy based on SMC for current-controlled converters

    Science.gov (United States)

    Azer, Peter M.; Marei, Mostafa I.; Sattar, Ahmed A.

    2018-05-01

    The sliding mode control (SMC) is used to control variable structure systems such as power electronics converters. This paper presents a fault-tolerant strategy based on the SMC for current-controlled AC-DC converters. The proposed SMC is based on three sliding surfaces for the three legs of the AC-DC converter. Two sliding surfaces are assigned to control the phase currents since the input three-phase currents are balanced. Hence, the third sliding surface is considered as an extra degree of freedom which is utilised to control the neutral voltage. This action is utilised to enhance the performance of the converter during open-switch faults. The proposed fault-tolerant strategy is based on allocating the sliding surface of the faulty leg to control the neutral voltage. Consequently, the current waveform is improved. The behaviour of the current-controlled converter during different types of open-switch faults is analysed. Double switch faults include three cases: two upper switch fault; upper and lower switch fault at different legs; and two switches of the same leg. The dynamic performance of the proposed system is evaluated during healthy and open-switch fault operations. Simulation results exhibit the various merits of the proposed SMC-based fault-tolerant strategy.

  4. Current controller considering harmonics compensation for grid connected converter in DPGS applications

    DEFF Research Database (Denmark)

    Barote, L.; Marinescu, C.; Teodorescu, Remus

    2012-01-01

    This paper deals with the design and implementation of PR current control method in the αβ stationary reference frame for the grid side converter in Distributed Power Generation Systems (DPGS) applications. The goals of this paper are to implement a control technique for the grid side inverter...... including a LC filter, a compensation technique for low-order harmonics and to examine the grid current harmonic content with and without harmonic compensation. A comparative study in terms of current harmonic distortion between two different values of PR proportional gain running in steady state condition...

  5. Enhanced Decoupled Double Synchronous Reference Frame Current Controller for Unbalanced Grid-Voltage Conditions

    DEFF Research Database (Denmark)

    Reyes, M.; Rodriguez, Pedro; Vazquez, S.

    2012-01-01

    . In these codes, the injection of positive- and negative-sequence current components becomes necessary for fulfilling, among others, the low-voltage ride-through requirements during balanced and unbalanced grid faults. However, the performance of classical dq current controllers, applied to power converters......, under unbalanced grid-voltage conditions is highly deficient, due to the unavoidable appearance of current oscillations. This paper analyzes the performance of the double synchronous reference frame controller and improves its structure by adding a decoupling network for estimating and compensating...

  6. Method for controlling low-energy high current density electron beams

    International Nuclear Information System (INIS)

    Lee, J.N.; Oswald, R.B. Jr.

    1977-01-01

    A method and an apparatus for controlling the angle of incidence of low-energy, high current density electron beams are disclosed. The apparatus includes a current generating diode arrangement with a mesh anode for producing a drifting electron beam. An auxiliary grounded screen electrode is placed between the anode and a target for controlling the average angle of incidence of electrons in the drifting electron beam. According to the method of the present invention, movement of the auxiliary screen electrode relative to the target and the anode permits reliable and reproducible adjustment of the average angle of incidence of the electrons in low energy, high current density relativistic electron beams

  7. Composition control of tin-zinc electrodeposits through means of experimental strategies

    International Nuclear Information System (INIS)

    Dubent, S.; De Petris-Wery, M.; Saurat, M.; Ayedi, H.F.

    2007-01-01

    Tin-zinc coatings offer excellent corrosion protection and do not suffer the drawback of the voluminous white corrosion product of pure zinc or high zinc alloy coatings. The aim of this study was to determine the suitable electroplating conditions (i.e. electrolyte composition and cathode current density) to produce 70Sn-30Zn electrodeposits. Thus, a fractional factorial design (FFD) was carried out to evaluate the effects of experimental parameters (Zn II concentration, Sn IV concentration, pH and current density) on the Zn content of the electrodeposit. On the other hand, the electrodeposits were characterised by glow discharge optical emission spectroscopy (GDOES) and scanning electron microscopy (SEM). Correlation between operating conditions, composition and morphology was attempted

  8. [Prospects in getting accordance between chemical analytic control means and medical technical requirements to safety system concerning chemical weapons destruction].

    Science.gov (United States)

    Rembovskiĭ, V R; Mogilenkova, L A; Savel'eva, E I

    2005-01-01

    The major unit monitoring chemical weapons destruction objects is a system of chemical analyticcontrol over the technologic process procedures and possibility of environment and workplace pollution withtoxicchemicals and their destruction products. At the same time, physical and chemical control means meet sanitary and hygienic requirements incompletely. To provide efficient control, internationally recognized approaches should be adapted to features of Russian system monitoring pollution of chemical weapons destruction objects with toxic chemicals.

  9. Control and ad ustment system of the BIS-2 spectrometer by means of a minicomputer

    International Nuclear Information System (INIS)

    Eichner, G.; Aleev, A.N.; Aref'ev, V.A.

    1980-01-01

    Control and adjustment system of the BIS-2 spectrometer apparatus is desribed. The work was intented to adjust time losses during the apparatus preparation and obtaing detailed information on the operation of basic parts of the spectrometer. To solve this problem the program-controlled electronic circuits working on-line with the TPA-1001/i computer were used and corresponding software was created. The flexibility and comparative simplicity of program designing was achieved by using the combination of FOKAL and SLAG1 programming languages. The examples of programs serving for the apparatus adjustment are given. The use of this control and adjustment system allows one to accelerate the preparation of the spectrometer for operation. The hardware-software complex can be used for various setups of experimental apparatus

  10. Quality control, mean glandular dose estimate and room shielding calculation in mammography

    International Nuclear Information System (INIS)

    Rakotomalala, H.M.

    2014-01-01

    This study focuses in the importance of Radiation Protection in mammography. A good control of the radiological risk depends on the dose optimization, room shielding calculation and the quality of equipment. The work was carried out in the three private medical centers called A, B, and C. Dosimetry estimates were made on the equipment of the three centers. Values has been compared with the Diagnostic Reference Levels established by the International Atomic Energy Agency (IAEA). Conformity control of the radiological devices has also been done with the Mammographic Quality Control Kit of the INSTN-Madagascar. Verifications of shields of the room containing the mammography equipment were done by theoretical calculations using the method provided by NCRP 147. [fr

  11. Active and reactive power control of a current-source PWM-rectifier using space vectors

    Energy Technology Data Exchange (ETDEWEB)

    Salo, M.; Tuusa, H. [Tampere University of Technology (Finland). Department of Electrical Engineering, Power Electronics

    1997-12-31

    In this paper the current-source PWM-rectifier with active and reactive power control is presented. The control system is realized using space vector methods. Also, compensation of the reactive power drawn by the line filter is discussed. Some simulation results are shown. (orig.) 8 refs.

  12. Towards Current Profile Control in ITER: Potential Approaches and Research Needs

    Science.gov (United States)

    Schuster, E.; Barton, J. E.; Wehner, W. P.

    2014-10-01

    Many challenging plasma control problems still need to be addressed in order for the ITER Plasma Control System (PCS) to be able to successfully achieve the ITER project goals. For instance, setting up a suitable toroidal current density profile is key for one possible advanced scenario characterized by noninductive sustainment of the plasma current and steady-state operation. The nonlinearity and high dimensionality exhibited by the plasma demand a model-based current-profile control synthesis procedure that can accommodate this complexity through embedding the known physics within the design. The development of a model capturing the dynamics of the plasma relevant for control design enables not only the design of feedback controllers for regulation or tracking but also the design of optimal feedforward controllers for a systematic model-based approach to scenario planning, the design of state estimators for a reliable real-time reconstruction of the plasma internal profiles based on limited and noisy diagnostics, and the development of a fast predictive simulation code for closed-loop performance evaluation before implementation. Progress towards control-oriented modeling of the current profile evolution and associated control design has been reported following both data-driven and first-principles-driven approaches. An overview of these two approaches will be provided, as well as a discussion on research needs associated with each one of the model applications described above. Supported by the US Department of Energy under DE-SC0001334 and DE-SC0010661.

  13. Start Up Current Control of Buck-Boost Convertor-Fed Serial DC Motor

    Directory of Open Access Journals (Sweden)

    Yusuf SÖNMEZ

    2009-02-01

    Full Text Available Generally, DC motors are given preference for industrial applications such as electric locomotives, cranes, goods lifts. Because of they have high starting moment; they initially start with high current. This high start-up current must be decreased since it may damage windings of the motor and increases power consumption. It could be controlled by an appropriate driver system and controller. The nature of fuzzy logic control has adaptive characteristics that can achieve robust response to a system with uncertainty, parameter variation, and load disturbance. In this paper, fuzzy logic based control of start-up current of a Buck-Boost Converter fed serial DC motor is examined through computer simulation. In order to see the advantages of fuzzy logic control, classical PI control has applied to the same motor, under same circumstances and has been compared. C++ Builder software has been used for the simulation. According to the simulation results, plainly, fuzzy logic control has stronger responses than classical PI control and uses lower current at starting moment.

  14. Controlling the switching field in nanomagnets by means of domain-engineered antiferromagnets

    Science.gov (United States)

    Folven, E.; Linder, J.; Gomonay, O. V.; Scholl, A.; Doran, A.; Young, A. T.; Retterer, S. T.; Malik, V. K.; Tybell, T.; Takamura, Y.; Grepstad, J. K.

    2015-09-01

    Using soft x-ray spectromicroscopy, we investigate the magnetic domain structure in embedded nanomagnets defined in L a0.7S r0.3Mn O3 thin films and LaFe O3/L a0.7S r0.3Mn O3 bilayers. We find that shape-controlled antiferromagnetic domain states give rise to a significant reduction of the switching field of the rectangular nanomagnets. This is discussed within the framework of competition between an intrinsic spin-flop coupling and shape anisotropy. The data demonstrates that shape effects in antiferromagnets may be used to control the magnetic properties in nanomagnets.

  15. Mitigation of grid-current distortion for LCL-filtered grid-connected voltage-source inverter with inverter-side current control

    DEFF Research Database (Denmark)

    Xin, Zhen; Mattavelli, Paolo; Yao, WenLi

    2017-01-01

    Due to the low inductance of an LCL-filter, the grid current generated by an LCL-filtered Voltage Source Inverter (VSI) is sensitive to low-order grid-voltage harmonics. This issue is especially tough for the control system with Inverter Current Feedback (ICF), because the grid-current harmonics...... can freely flow into the filter capacitor without control. To cope with this issue, this paper develops an approach for the ICF control system to suppress the grid-current harmonics without adding extra sensors. The proposed method applies harmonic controllers and feedforward scheme simultaneously...

  16. Current error vector based prediction control of the section winding permanent magnet linear synchronous motor

    Energy Technology Data Exchange (ETDEWEB)

    Hong Junjie, E-mail: hongjjie@mail.sysu.edu.cn [School of Engineering, Sun Yat-Sen University, Guangzhou 510006 (China); Li Liyi, E-mail: liliyi@hit.edu.cn [Dept. Electrical Engineering, Harbin Institute of Technology, Harbin 150000 (China); Zong Zhijian; Liu Zhongtu [School of Engineering, Sun Yat-Sen University, Guangzhou 510006 (China)

    2011-10-15

    Highlights: {yields} The structure of the permanent magnet linear synchronous motor (SW-PMLSM) is new. {yields} A new current control method CEVPC is employed in this motor. {yields} The sectional power supply method is different to the others and effective. {yields} The performance gets worse with voltage and current limitations. - Abstract: To include features such as greater thrust density, higher efficiency without reducing the thrust stability, this paper proposes a section winding permanent magnet linear synchronous motor (SW-PMLSM), whose iron core is continuous, whereas winding is divided. The discrete system model of the motor is derived. With the definition of the current error vector and selection of the value function, the theory of the current error vector based prediction control (CEVPC) for the motor currents is explained clearly. According to the winding section feature, the motion region of the mover is divided into five zones, in which the implementation of the current predictive control method is proposed. Finally, the experimental platform is constructed and experiments are carried out. The results show: the current control effect has good dynamic response, and the thrust on the mover remains constant basically.

  17. A current controlled matrix converter for wind energy conversion systems based on permanent magnet synchronous generator

    Directory of Open Access Journals (Sweden)

    Naggar H. Saad

    2016-05-01

    Full Text Available The main challenges of wind energy conversion systems (WECS are to maximize the energy capture from the wind and injecting reactive power during the fault. This paper presents a current controlled matrix converter to interface Permanent Magnet Synchronous Generators (PMSG based WECS with the grid. To achieve fast dynamic response with reduced current ripples, a hysteresis current control is utilized. The proposed control system decouples the active and reactive components of the PMSG current to extract the maximum power from the wind at a given wind velocity and to inject reactive power to the grid. Reactive power injection during the fault satisfying the grid-codes requirement. The proposed WECS has been modeled and simulated using PSCAD/EMTDC software package.

  18. Large-current-controllable carbon nanotube field-effect transistor in electrolyte solution

    Science.gov (United States)

    Myodo, Miho; Inaba, Masafumi; Ohara, Kazuyoshi; Kato, Ryogo; Kobayashi, Mikinori; Hirano, Yu; Suzuki, Kazuma; Kawarada, Hiroshi

    2015-05-01

    Large-current-controllable carbon nanotube field-effect transistors (CNT-FETs) were fabricated with mm-long CNT sheets. The sheets, synthesized by remote-plasma-enhanced CVD, contained both single- and double-walled CNTs. Titanium was deposited on the sheet as source and drain electrodes, and an electrolyte solution was used as a gate electrode (solution gate) to apply a gate voltage to the CNTs through electric double layers formed around the CNTs. The drain current came to be well modulated as electrolyte solution penetrated into the sheets, and one of the solution gate CNT-FETs was able to control a large current of over 2.5 A. In addition, we determined the transconductance parameter per tube and compared it with values for other CNT-FETs. The potential of CNT sheets for applications requiring the control of large current is exhibited in this study.

  19. Reduction of broadband noise in vehicles by means of active feedforward control

    OpenAIRE

    Misol, Malte; Haase, Thomas; Monner, Hans Peter

    2015-01-01

    Broadband noise in a vehicle’s interior is an important issue because of its negative impact on the passengersʼ comfort and wellbeing. The perception of this broadband noise can increase due to the use of new, less noisy drive concepts and the accompanying loss of masking noise compo-nents. This contribution focuses on the reduction of the transmission of external broadband distur-bances through lightweight panel structures (e.g. a car’s roof liner or an aircraft sidewall panel) by means of a...

  20. Mean-risk optimal decision of a steel company under emission control

    Czech Academy of Sciences Publication Activity Database

    Zapletal, F.; Šmíd, Martin

    2016-01-01

    Roč. 24, č. 2 (2016), s. 435-454 ISSN 1435-246X R&D Projects: GA ČR(CZ) GBP402/12/G097; GA ČR GA13-25911S Grant - others:EC(XE) SP2014/146; EC(XE) SP2013/148 Institutional support: RVO:67985556 Keywords : Stochastic programming * Risk management * Mean-risk modeling * Emissions trading * Emissions management Subject RIV: BB - Applied Statistics, Operational Research Impact factor: 0.659, year: 2016 http://library.utia.cas.cz/separaty/2015/E/smid-0451991.pdf

  1. Importance weighting and andness control in De Morgan dual power means and OWA operators

    DEFF Research Database (Denmark)

    Larsen, Henrik Legind

    2012-01-01

    (minimum) and the max (maximum), the so-called averaging operators. Two key issues in the choice of such an operator for a given application are the kind of importance weighting and the andness (“minness”) of the operator. Two main kinds of importance weighting for such operators, namely multiplicative...... and implicative, are proposed and discussed. The purpose of this paper is to facilitate the choice and application of such operators through providing a systematization of their classes according to their behavior and equipping some classical averaging operators, namely the Power Means and the OWA operators...

  2. Rotor Current Control of DFIG for Improving Fault Ride - Through Using a Novel Sliding Mode Control Approach

    Science.gov (United States)

    Cai, Guowei; Liu, Cheng; Yang, Deyou

    2013-11-01

    The doubly fed induction generators (DFIG) have been recognized as the dominant technology used in wind power generation systems with the rapid development of wind power. However, continuous operation of DFIG may cause a serious wind turbine generators tripping accident, due to destructive over-current in the rotor winding which is caused by the power system fault or inefficient fault ride-through (FRT) strategy. A new rotor current control scheme in the rotor-side converter (RSC) ispresented to enhance FRT capacities of grid-connected DFIG. Due to the strongly nonlinear nature of DFIG and insensitive to DFIG parameter's variations, a novel sliding mode controller was designed. The controller combines extended state observer (ESO) with sliding model variable structure control theory. The simulation is carried out to verify the effectiveness of the proposed control approach under various types of grid disturbances. It is shown that the proposed controller provides enhanced transient features than the classic proportional-integral control. The proposed control method can effectively reduce over-current in the RSC, and the transient pulse value of electromagnetic torque is too large under power grid fault.

  3. Biological control in agro-systems by means of the handling of entomophagous insects

    International Nuclear Information System (INIS)

    Nicholls, Clara Ines; Altieri, Miguel A

    1998-01-01

    From several decades ago the importance of natural enemies of the noxious organisms has been recognized. Unfortunately the introduction of the biological control has not had the desired dimension. The indiscriminate use of biocides products has altered the biodiversity of the agro-ecosystem. The parasitoids and predators have suffered the noxious effects of the plaguicides. These natural enemies of the plagues play a momentous paper in the regulation of noxious insects population. The predators of the insecta class register in diverse orders and the abundance of species is impressive. But the knowledge of their importance is only partial. In many countries the kindness of these organisms has not been specified and does not protect them. In the case of parasitoids something similar occurs. It is say that their biotic diversity is incalculable but very few species are exploited. In these two groups rest the classic biological control projects. The successes in projects of biological control are recognized and they are enlarging in several countries but more impulse is required. Due to demands of a sustainable agricultural production it should support the biological control of plagues. In this document general looks on the topic are expounded

  4. Control of the beam-internal target interaction at the nuclotron by means of light radiation

    Energy Technology Data Exchange (ETDEWEB)

    Artiomov, A.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation)]. E-mail: artiomov@moonhe.jinr.ru; Anisimov, Yu.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Afanasiev, S.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Bazilev, S.N. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Zolin, L.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Issinsky, I.B. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Kliman, J. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Malakhov, A.I. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Matousek, V. [Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Morhac, M. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia); Nikitin, V.A. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Nikiforov, A.S. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Nomokonov, P.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Pilyar, A.V. [Laboratory of High Energies, Joint Institute for Nuclear Research, Dubna 141980 (Russian Federation); Turzo, I. [Institute of Physics, Slovak Academy of Sciences, Bratislava (Slovakia)

    2005-02-11

    The light radiation from various internal targets at the nuclotron can be utilized for the operative control and time optimization of the interaction intensity of the beam. The examples presented in the paper illustrate information about the space characteristics of the circulating beam during one cycle of the accelerator run at the stages of injection, acceleration and during the physical experiments, respectively.

  5. Measured results of polarization crosstalk cancellation using LMS control. [Least Mean Square

    Science.gov (United States)

    Baird, C. A.; Rassweiler, G. G.

    1977-01-01

    This paper discusses the use of wideband decoupling networks for the cancellation of polarization crosstalk in dual-polarized communication links. Measured cancellation performance for an all-electronic IF network and an RF electro-mechanical waveguide network are presented. Each of these networks utilizes LMS-type adaptive control techniques to adjust the cancellation network.

  6. Screening of micro-organisms for Venturia inaequalis control by means of DGGE

    NARCIS (Netherlands)

    Speksnijder, A.G.C.L.; Lombaers-van der Plas, C.H.; Köhl, J.

    2006-01-01

    Venturia inaequalis causes apple scab. The control of the disease in organic apple production depends on the use of copper which will be restricted in future for environmental reasons. In the search for environmental friendly microbial biocontrol agents and stimulation of antagonistic populations in

  7. Particle Control in Phase Space by Global K-Means Clustering

    DEFF Research Database (Denmark)

    Frederiksen, Jacob Trier; Lapenta, G.; Pessah, M. E.

    2015-01-01

    We devise and explore an iterative optimization procedure for controlling particle populations in particle-in-cell (PIC) codes via merging and splitting of computational macro-particles. Our approach, is to compute an optimal representation of the global particle phase space structure while decre...

  8. External Carbon Source Addition as a Means to Control an Activated Sludge Nutrient Removal Process

    DEFF Research Database (Denmark)

    Isaacs, Steven Howard; Henze, Mogens; Søeberg, Henrik

    1994-01-01

    In alternating type activated sludge nutrient removal processes, the denitrification rate can be limited by the availability of readily-degradable carbon substrate. A control strategy is proposed by which an easily metabolizable COD source is added directly to that point in the process at which d...

  9. Plug-and-play control and consensus algorithms for current sharing in DC microgrids

    DEFF Research Database (Denmark)

    Tucci, Michele; Meng, Lexuan; Guerrero, Josep M.

    2017-01-01

    In this paper, we propose a secondary consensus-based control layer for current sharing and voltage balancing in DC microGrids (mGs). Differently from existing approaches based on droop control, we assume decentralized Plug-and-Play (PnP) regulators at the primary level, as they provide voltage...... functions (Tucci et al., 2016a). Besides showing stability, current sharing, and voltage balancing in the asymptotic régime, we describe how to design secondary controllers in a PnP fashion when Distributed Generation Units (DGUs) are added or removed. Theoretical results are complemented by simulations...

  10. Design of PR current control with selective harmonic compensators using Matlab

    Directory of Open Access Journals (Sweden)

    Daniel Zammit

    2017-12-01

    Full Text Available This paper presents a procedure to design a Proportional Resonant (PR current controller with additional PR selective harmonic compensators for Grid Connected Photovoltaic (PV Inverters. The design of the PR current control and the harmonic compensators will be carried out using Matlab. Testing was carried out on a 3 kW Grid-Connected PV Inverter which was designed and constructed for this research. Both simulation and experimental results will be presented. Keywords: Inverters, Proportional-resonant controllers, Harmonic compensation, Photovoltaic, Matlab, SISO design tool

  11. Load Torque Compensator for Model Predictive Direct Current Control in High Power PMSM Drive Systems

    DEFF Research Database (Denmark)

    Preindl, Matthias; Schaltz, Erik

    2011-01-01

    The widely used cascade speed and torque controllers have a limited control performance in most high power applications due to the low switching frequency of power electronic converters and the convenience to avoid speed overshoots and oscillations for lifetime considerations. Model Predictive...... Direct Current Control (MPDCC) leads to an increase of torque control performance taking into account the discrete nature of inverters but temporary offsets and poor responses to load torque variations are still issues in speed control. A load torque estimator is proposed in this paper in order...

  12. Mechanisms Controlling Global Mean Sea Surface Temperature Determined From a State Estimate

    Science.gov (United States)

    Ponte, R. M.; Piecuch, C. G.

    2018-04-01

    Global mean sea surface temperature (T¯) is a variable of primary interest in studies of climate variability and change. The temporal evolution of T¯ can be influenced by surface heat fluxes (F¯) and by diffusion (D¯) and advection (A¯) processes internal to the ocean, but quantifying the contribution of these different factors from data alone is prone to substantial uncertainties. Here we derive a closed T¯ budget for the period 1993-2015 based on a global ocean state estimate, which is an exact solution of a general circulation model constrained to most extant ocean observations through advanced optimization methods. The estimated average temperature of the top (10-m thick) level in the model, taken to represent T¯, shows relatively small variability at most time scales compared to F¯, D¯, or A¯, reflecting the tendency for largely balancing effects from all the latter terms. The seasonal cycle in T¯ is mostly determined by small imbalances between F¯ and D¯, with negligible contributions from A¯. While D¯ seems to simply damp F¯ at the annual period, a different dynamical role for D¯ at semiannual period is suggested by it being larger than F¯. At periods longer than annual, A¯ contributes importantly to T¯ variability, pointing to the direct influence of the variable ocean circulation on T¯ and mean surface climate.

  13. A novel current mode controller for a static compensator utilizing Goertzel algorithm to mitigate voltage sags

    International Nuclear Information System (INIS)

    Najafi, E.; Yatim, A.H.M.

    2011-01-01

    Research highlights: → We proposed a new current control method for STATCOM. → The current control method maintains a fixed switching frequency. → It also produces fewer harmonics compared to conventional hysteresis method. → A new voltage dip (sag) detection method was used in STATCOM. → The control method can mitigate voltage sag in each phase separately. -- Abstract: Static compensator (STATCOM) has been widely proposed for power quality and network stability improvement. It is easily connected in parallel to the electric network and has many advantages for electrical grids. It can improve network stability; power factor, power transfer rating and can avoid some disturbances such as sags and swells. Most of STATCOM controllers are based on voltage controllers that are based on balanced d-q transform. However, they are not thorough solutions for network disturbances since in most cases single-phase disturbances occur in electrical networks that cannot be avoided by the conventional controllers. Voltage mode controllers are also not capable of responding fast enough to the changes expected of a network system. This paper proposes a new current mode controller to overcome the mentioned problem. The approach uses a fixed frequency current controller to maintain voltage levels in voltage sags (dips). This approach is also simple and can be easily implemented by digitally. It has superior performance over conventional methods in terms of harmonic reduction in STATCOM output current. Another important factor for STATCOM effectiveness in sag mitigation is its sag detection method. This paper also introduces a new sag detection method based on Goertzel algorithm which is both effective and simple for practical applications. The simulation results presented illustrate the superiority of the proposed controller and sag detection algorithm to be utilized in the STATCOM.

  14. River flow controls on tides an tide-mean water level profiles in a tidel freshwater river

    NARCIS (Netherlands)

    Sassi, M.G.; Hoitink, A.J.F.

    2013-01-01

    [1] Tidal rivers feature oscillatory and steady gradients in the water surface, controlled by interactions between river flow and tides. The river discharge attenuates the tidal motion, and tidal motion increases tidal-mean friction in the river, which may act as a barrier to the river discharge.

  15. Cultural Considerations: Pharmacological and Nonpharmacological Means for Improving Blood Pressure Control among Hispanic Patients

    Directory of Open Access Journals (Sweden)

    Neela K. Patel

    2012-01-01

    Full Text Available Cardiovascular disease is a leading cause of morbidity and mortality in the United States, and its prevention and treatment remain a priority for the medical community. Ethnic variations account for some differences in the prevalence of hypertension and blood pressure (BP control rates among Hispanics, indicating the need for culturally appropriate management models. Aggressive treatment strategies are key to achieving optimal BP control in high-risk Hispanic patients. Hypertension in this ethnic group continues to be a major health concern. Of note, when provided access to comprehensive care, Hispanics demonstrate similar response rates to treatment as the majority of non-Hispanic whites. This highlights the importance of effective, culturally responsive hypertension management among high-risk Hispanic patients for achieving observable, positive health outcomes.

  16. Means to improve underground coal mine safety by automated control of methane drainage systems

    Directory of Open Access Journals (Sweden)

    Babut Gabriel Bujor

    2017-01-01

    Full Text Available Based on the critical analysis of the presently employed management of methane drainage systems operation in Jiu Valley collieries, the paper aims to assess the basic elements required to develop an automated monitoring and control system of these. The results obtained after studies and researches carried out also allowed formulating certain proposals regarding the modification of manual control procedures of methane drainage systems operation, in order to correlate them with the prescriptions of legislation requirements from countries having a well-developed mining industry. Putting in practice the mentioned proposals could have immediate and beneficial effects on increasing the methane drainage process efficiency, leading meanwhile to an improved working environment and, implicitly, to a higher level of occupational safety and health in Jiu Valley collieries.

  17. Stabilization of a semilinear parabolic equation in the exterior of a bounded domain by means of boundary controls

    International Nuclear Information System (INIS)

    Gorshkov, A V

    2003-01-01

    The problem of the stabilization of a semilinear equation in the exterior of a bounded domain is considered. In view of the impossibility of an exponential stabilization of the form e -σt of the solution of a parabolic equation in an unbounded domain no matter what the boundary control is, one poses the problem of power-like stabilization by means of a boundary control. For a fixed initial condition and parameter k>0 of the rate of stabilization the existence of a boundary control such that the solution approaches zero at the rate 1/t k is demonstrated

  18. Evaluation of a Pomegranate Peel Extract as an Alternative Means to Control Olive Anthracnose.

    Science.gov (United States)

    Pangallo, Sonia; Nicosia, Maria G Li Destri; Agosteo, Giovanni E; Abdelfattah, Ahmed; Romeo, Flora V; Cacciola, Santa O; Rapisarda, Paolo; Schena, Leonardo

    2017-12-01

    Olive anthracnose is caused by different species of Colletotrichum spp. and may be regarded as the most damaging disease of olive fruit worldwide, greatly affecting quality and quantity of the productions. A pomegranate peel extract (PGE) proved very effective in controlling the disease. The extract had a strong in vitro fungicidal activity against Colletotrichum acutatum sensu stricto, was very effective in both preventive and curative trials with artificially inoculated fruit, and induced resistance in treated olive tissues. In field trials, PGE was significantly more effective than copper, which is traditionally used to control the disease. The highest level of protection was achieved by applying the extract in the early ascending phase of the disease outbreaks because natural rots were completely inhibited with PGE at 12 g/liter and were reduced by 98.6 and by 93.0% on plants treated with PGE at 6 and 3 g/liter, respectively. Two treatments carried out 30 and 15 days before the expected epidemic outbreak reduced the incidence of the disease by 77.6, 57.0, and 51.8%, depending on the PGE concentration. The analysis of epiphytic populations showed a strong antimicrobial activity of PGE, which sharply reduced both fungal and bacterial populations. Because PGE was obtained from a natural matrix using safe chemicals and did not have any apparent phytotoxic effect on treated olive fruit, it may be regarded as a safe and effective natural antifungal preparation to control olive anthracnose and improve olive productions.

  19. Esthesioneuroblastoma - treatment of recurrences by means of remote-controlled afterloading-technique

    International Nuclear Information System (INIS)

    Schulz-Wendtland, R.; Bauer, M.; Wilhelm, K.R.; Mende, U.; Dreyer, M.

    1990-01-01

    At the Radiological Hospital of the Heidelberg University, one patient with a local recurrence of an esthesioneuroblastoma situated on the left-hand side of the skull base was treated between February 11 and March 18, 1986, by an afterloading contact therapy with curative intent. After preceding surgery and percutaneous radiotherapy, repeated local recurrences and locoregional lymph node metastases had occured. The contact therapy was performed after adjusting an individual face mask in which the afterloading probe was placed and brought into its position in the tumor region. The irradiation scheme was based on the transformation of the source coordinates from the stereoscopic X-ray localization system into the coordinate system of the computed tomogram by means of X-ray right reference points. The irradiation planning by computed tomography allows to optimize the arrangement of sources within the tumor region. The principles of the method as well as the treatment result are presented. (orig.) [de

  20. Study on the Electronic Magnetic Field Oriented Control Based on D-axis Current

    Directory of Open Access Journals (Sweden)

    Hongyu Feng

    2014-07-01

    Full Text Available In order to improve the magnetic field orientation accuracy and system performance, the electronic field oriented control has been a hot research field of the induction motor speed control. Although the vector control of AC machines has many excellent properties, the researchers have been attempting to simplify the calculating steps and the structure of the control system to improve the accuracy of filed-oriented and the performance of AC machine drives. Based on the analysis of the conventional induction motor magnetic field oriented control, this paper puts forward a novel method of stator magnetic field orientation control. By analytical methods, the given current of d-axis can be calculated directly, and the stator flux can be controlled precisely. This method has a fast flux and torque response, and the control performance is unaffected by the rotor parameters.

  1. Integrated analysis of CFD data with K-means clustering algorithm and extreme learning machine for localized HVAC control

    International Nuclear Information System (INIS)

    Zhou, Hongming; Soh, Yeng Chai; Wu, Xiaoying

    2015-01-01

    Maintaining a desired comfort level while minimizing the total energy consumed is an interesting optimization problem in Heating, ventilating and air conditioning (HVAC) system control. This paper proposes a localized control strategy that uses Computational Fluid Dynamics (CFD) simulation results and K-means clustering algorithm to optimally partition an air-conditioned room into different zones. The temperature and air velocity results from CFD simulation are combined in two ways: 1) based on the relationship indicated in predicted mean vote (PMV) formula; 2) based on the relationship extracted from ASHRAE RP-884 database using extreme learning machine (ELM). Localized control can then be effected in which each of the zones can be treated individually and an optimal control strategy can be developed based on the partitioning result. - Highlights: • The paper provides a visual guideline for thermal comfort analysis. • CFD, K-means, PMV and ELM are used to analyze thermal conditions within a room. • Localized control strategy could be developed based on our clustering results

  2. Harmonic Mitigation Using a Polarized Ramp-time Current-Controlled Inverter

    Directory of Open Access Journals (Sweden)

    Lawrence J. Borle

    2010-12-01

    Full Text Available This paper describes the implementation of a shunt active power filter for a three-phase four-wire system to compensate for power quality problems generated by mixed non-linear loads, which are a combination of harmonic, reactive and unbalanced components. The filter is a three-phase current-controlled voltage source inverter (CC-VSI with a filter inductor at the AC output and a DC-bus capacitor. The CC-VSI is operated to directly control the grid current to be sinusoidal and in phase with the grid voltage without sensing the load currents. The switching is controlled using polarized ramp-time current control, which is based on the concept of zero average current error (ZACE with a fixed switching frequency. The laboratory experiment results indicate that the filter is able to mitigate predominantly the harmonics, as well as the reactive power, so that the grid currents are sinusoidal, in phase with the grid voltages and symmetrical although the grid voltage contains harmonics.

  3. MEANS OF CHEMICAL RECONNAISSANCE AND CONTROL IN THE FIGHT AGAINST CBRN TERRORISM

    Directory of Open Access Journals (Sweden)

    Dušan VIČAR

    2013-01-01

    Full Text Available The chemical, biological, radiological and nuclear terrorism (CBRN terrorism is a special form of terrorism known for its extraordinary efficiency as superterrorism or ultra-terrorism. Detection and identification of the presence of hazardous chemical toxic substances is very difficult and can be achieved only by using advanced detection and monitoring instruments and devices that are currently only in the equipment of units of the Fire and Rescue Service of the Czech Republic and some units of the chemical troops of the Czech Army. Instigators of chemical terrorism count on the surprise factor, as well as on the difficulty and great delay in detecting the presence of hazardous chemical toxic substances. Therefore, for early warning of the population and minimization of consequences of a terrorist attack with the use of hazardous chemicals, the ability of early detection and subsequent identification is very important.

  4. SOME CONSIDERATIONS OVER THE INTERNAL CONTROL IN THE CONTEXT OF CURRENT ACCOUNTANCY REGULATIONS

    Directory of Open Access Journals (Sweden)

    Lenghel Dorin Radu

    2012-12-01

    Full Text Available Through the hereby study we set ourselves on an analysis over the internal control and the ways of implementation of it. The final purpose of our research is represented by the characteristics of the internal control system in the context of current accountancy regulations. The accomplishment of such goal has forced us to research the current literature in the area and also the legal regulations over internal control. Of course, the accomplishment of such a research was possible only after a pertinent analysis over the opinions expressed in specialty literature regarding this area. Our research wants to be with a theoretical and applicative character. It is based on analysing the internal control system, the methodology of internal control and the steps of internal control. We express our belief that the implementation of the internal control in a very exact manner comes as an aid to the company management and lead to the accomplishment of managerial objectives and policies. In what it regards the result of our research there can be drawn the following conclusions: from the legal regulations (OMFP nr. 3055/2009, there is no clear conclusion over the procedures and policies of implementation of internal control applicable to an economical entity; also there are not presented in a detailed way the types (forms of internal control, being presented in the legal regulations only a classification of them after the time in which they are exercised (before, during or after the finishing of the operations; also in the legal regulations there is developed a certain way of internal control, represented by the financial and accounting internal control, as if the other forms of internal control do not exist; in what regards the components of internal control, these are presented in another way, but similar to already known models of internal control (Coso and Coco; also in the legal regulations there are presented the general objectives of internal control

  5. A real-time current driving control system for the TJ-II coils

    International Nuclear Information System (INIS)

    Pena, Angel de la; Pacios, Luis; Carrasco, Ricardo; Lapayese, Fernando

    2009-01-01

    Since the start of plasma operation in the TJ-II stellarator, the required values of DC currents that are fed to its different coil sets have been controlled to high precision along the complete discharge flat-top. As a result each current configuration produced a highly stable magnetic-field configuration. Recently, the configurational flexibility of the TJ-II has been broadened by the commissioning of a new mode of operation that allows magnetic configurations to be varied dynamically during the discharge flat-top. In order to achieve this, new hardware and software features have been added to the TJ-II Control System. These new features may also provide new strategies for feedback control in accordance with parameters measured in one or more diagnostics. In this new set-up, coil current profiles are generated and controlled to millisecond timescales by a system based on VMEbus and OS9 real-time operating system. A new communication middleware architecture called XML-based Messages Distribution Service (X-MDS) has been designed to exchange XML-based data with calling clients. Furthermore, with this software, a fully functional Java application for supervision and for current profiles settings has been developed. This paper provides a detailed description of the complete TJ-II real-time current-profile control system and results obtained during its operation.

  6. A real-time current driving control system for the TJ-II coils

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Angel de la [Association EURATOM - CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain)], E-mail: a.delapena@ciemat.es; Pacios, Luis; Carrasco, Ricardo; Lapayese, Fernando [Association EURATOM - CIEMAT, Avda. Complutense 22, 28040 Madrid (Spain)

    2009-06-15

    Since the start of plasma operation in the TJ-II stellarator, the required values of DC currents that are fed to its different coil sets have been controlled to high precision along the complete discharge flat-top. As a result each current configuration produced a highly stable magnetic-field configuration. Recently, the configurational flexibility of the TJ-II has been broadened by the commissioning of a new mode of operation that allows magnetic configurations to be varied dynamically during the discharge flat-top. In order to achieve this, new hardware and software features have been added to the TJ-II Control System. These new features may also provide new strategies for feedback control in accordance with parameters measured in one or more diagnostics. In this new set-up, coil current profiles are generated and controlled to millisecond timescales by a system based on VMEbus and OS9 real-time operating system. A new communication middleware architecture called XML-based Messages Distribution Service (X-MDS) has been designed to exchange XML-based data with calling clients. Furthermore, with this software, a fully functional Java application for supervision and for current profiles settings has been developed. This paper provides a detailed description of the complete TJ-II real-time current-profile control system and results obtained during its operation.

  7. Remote control of data acquisition devices by means of message oriented middleware

    International Nuclear Information System (INIS)

    Sanchez, E.; Portas, A.; Pereira, A.; Vega, J.; Kirpitchev, I.

    2007-01-01

    The TJ-II autonomous acquisition systems are computers running dedicated applications for programming and controlling data acquisition channels and also integrating acquired data into the central database. These computers are located in the experimental hall and have to be remotely controlled during plasma discharges. A remote control for these systems has been implemented by taking advantage of the message-oriented middleware recently introduced into the TJ-II data acquisition system. Java Message Service (JMS) is used as the messaging application program interface. All the acquisition actions that are available through the system console of the data acquisition computers (starting or aborting an acquisition, restarting the system or updating the acquisition application) can now be initiated remotely. Command messages are sent to the acquisition systems located in the experimental hall close to the TJ-II device by using the messaging software, without having to use a remote desktop application that produces heavy network traffic and requires manual operation. Action commands can be sent to only one or to several/many acquisition systems at the same time. This software is integrated into the TJ-II remote participation system and the acquisition systems can be commanded from inside or outside the laboratory. All this software is integrated into the security framework provided by PAPI, thus preventing non-authorized users commanding the acquisition computers. In order to dimension and distribute messaging services some performance tests of the message oriented middleware software have been carried out. Results of the tests are presented. As suggested by the tests results different transport connectors are used: TCP transport protocol is used for the local environment, while HTTP protocol is used for remote accesses, thereby allowing the system performance to be optimized

  8. Remote control of data acquisition devices by means of message oriented middleware

    Energy Technology Data Exchange (ETDEWEB)

    Sanchez, E. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)], E-mail: edi.sanchez@ciemat.es; Portas, A.; Pereira, A.; Vega, J.; Kirpitchev, I. [Asociacion EURATOM/CIEMAT para Fusion, Madrid (Spain)

    2007-10-15

    The TJ-II autonomous acquisition systems are computers running dedicated applications for programming and controlling data acquisition channels and also integrating acquired data into the central database. These computers are located in the experimental hall and have to be remotely controlled during plasma discharges. A remote control for these systems has been implemented by taking advantage of the message-oriented middleware recently introduced into the TJ-II data acquisition system. Java Message Service (JMS) is used as the messaging application program interface. All the acquisition actions that are available through the system console of the data acquisition computers (starting or aborting an acquisition, restarting the system or updating the acquisition application) can now be initiated remotely. Command messages are sent to the acquisition systems located in the experimental hall close to the TJ-II device by using the messaging software, without having to use a remote desktop application that produces heavy network traffic and requires manual operation. Action commands can be sent to only one or to several/many acquisition systems at the same time. This software is integrated into the TJ-II remote participation system and the acquisition systems can be commanded from inside or outside the laboratory. All this software is integrated into the security framework provided by PAPI, thus preventing non-authorized users commanding the acquisition computers. In order to dimension and distribute messaging services some performance tests of the message oriented middleware software have been carried out. Results of the tests are presented. As suggested by the tests results different transport connectors are used: TCP transport protocol is used for the local environment, while HTTP protocol is used for remote accesses, thereby allowing the system performance to be optimized.

  9. Grape juice quality control by means of {sup 1}H NMR spectroscopy and chemometric analyses

    Energy Technology Data Exchange (ETDEWEB)

    Grandizoli, Caroline Werner Pereira da Silva; Campos, Francinete Ramos; Simonelli, Fabio; Barison, Andersson [Universidade Federal do Paraná (UFPR), Curitiba (Brazil). Departamento de Química

    2014-07-01

    This work shows the application of {sup 1}H NMR spectroscopy and chemometrics for quality control of grape juice. A wide range of quality assurance parameters were assessed by single {sup 1}H NMR experiments acquired directly from juice. The investigation revealed that conditions and time of storage should be revised and indicated on all labels. The sterilization process of homemade grape juices was efficient, making it possible to store them for long periods without additives. Furthermore, chemometric analysis classified the best commercial grape juices to be similar to homemade grape juices, indicating that this approach can be used to determine the authenticity after adulteration. (author)

  10. Course control in rheumatic arthritis by means of X-ray and scintiscanning examinations

    International Nuclear Information System (INIS)

    Grebe, S.F.; Dreher, R.; Hanheide, H.; Virian, M.; Faengewisch, G.L.; Mueller, H.; Altaras, J.; Federlin, K.

    In contact to the X-ray examinations, the scintiscanning permits the recognition of the probable rheumatic arthritis. Furthermore, the quantitative scintiscanning values show the activity of a process and hence are a control of the therapy. This is not possible with X-rays. The latter merely show the advance of the degenerative process. The increase of the inflammation index in some cases does not always run parallel to the dose of both radiopharmaceuticals. These problems must be clarified in further investigations. (orig./AJ) [de

  11. CAMAC module control from the TPA-1001/i by means of the FOCAL programming language

    International Nuclear Information System (INIS)

    Angelov, A.Kh.; Dubovik, L.V.

    1977-01-01

    The possibility of using FOCAL programming language to control CAMAC modules by minicomputer is considered. This language allows to make effective changes in the program and reduce the time necessary for writing and running programmes. To address CAMAC modules a packet of CAMAC subroutines from the CAMAC-tr A/i software is included into FOCAL language, its operational possibilities and linguistic peculiarities being completely preserved. A big fast memory enables one to add three additional functions to the function list of FOCAL language. An example is given illustrating the use of these functions

  12. Cultural Meaning of Perceived Control: A Meta-Analysis of Locus of Control and Psychological Symptoms across 18 Cultural Regions

    Science.gov (United States)

    Cheng, Cecilia; Cheung, Shu-fai; Chio, Jasmine Hin-man; Chan, Man-pui Sally

    2013-01-01

    Integrating more than 40 years of studies on locus of control (LOC), this meta-analysis investigated whether (a) the magnitude of the relationship between LOC and psychological symptoms differed among cultures with distinct individualist orientations and (b) depression and anxiety symptoms yielded different patterns of cultural findings with LOC.…

  13. Two-group Current-equivalent Parameters for Control Rod Cells. Autocode Programme CRCC

    Energy Technology Data Exchange (ETDEWEB)

    Norinder, O; Nyman, K

    1962-06-15

    In two-group neutron diffusion calculations there is mostly necessary to describe the influence of control rods by equivalent homogeneous two-group parameters in regions about the control rods. The problem is solved for a control rod in a medium characterized by two-group parameters. The property of fast and thermal neutr. on current equivalence is selected to obtain equivalent two-group parameters for a homogeneous cell with the same radius as the control rod cell. For the parameters determined one obtains the same fast and thermal neutron current into the rod cell and the equivalent cell independent of the fast and thermal flux amplitudes on the cell boundaries. The equivalent parameters are obtained as a solution of a system of transcendental equations. A Ferranti Mercury Autocode performing the solution is described. Calculated equivalent parameters for control rods in a heavy water lattice are given for some representative cases.

  14. High-frequency, three-phase current controller implementation in an FPGA

    Energy Technology Data Exchange (ETDEWEB)

    Hartmann, M.; Round, S. D.; Kolar, J. W.

    2008-07-01

    Three phase rectifiers with switching frequencies of 500 kHz or more require high speed current controllers. At such high switching frequencies analog controllers as well as high speed digital signal processing (DSP) systems have limited performance. In this paper, two high speed current controller implementations using two different field-programmable gate arrays (FPGA) - one for switching frequencies up to 1 MHz and one for switching frequencies beyond 1 MHz - are presented to overcome this performance limitation. Starting with the digital system design all the blocks of the signal chain, containing analog-to-digital (A/D) interface, digital controller implementation using HW-multipliers and implementation of a novel high speed, high resolution pulse width modulation (PWM) are discussed and compared. Final measurements verify the performance of the controllers. (author)

  15. [Blood-sugar self control. A means for the diabetic of controlling his metabolic management. Quality control of a battery-run pocket size reflectometer (glucose-meter)].

    Science.gov (United States)

    Leidinger, F; Jörgens, V; Chantelau, E; Berchtold, P; Berger, M

    1980-07-26

    Home blood glucose monitoring by diabetic patients has recently been advocated as an effective means to improve metabolic control. The Glucocheck apparatus, a pocket-size battery-driven reflectance-meter (in Germany commercially available under the name Glucose-meter), has been evaluated for accuracy and practicability. In 450 blood glucose measurements, the variance between the values obtained using the Glucocheck apparatus and routine clinical laboratory procedures was +/- 11.7%. Especially in the low range of blood glucose concentrations, the Glucocheck method was very reliable. The quantitative precision of the Glucocheck method depends, however, quite considerably on the ability of the patient to use the apparatus correctly. In order to profit from Glucocheck in clinical practice, particular efforts to educate the patients in its use are necessary.

  16. By passing microbial resistance: xylitol controls microorganisms growth by means of its anti-adherence property.

    Science.gov (United States)

    Ferreira, Aline S; Silva-Paes-Leme, Annelisa F; Raposo, Nádia R B; da Silva, Sílvio S

    2015-01-01

    Xylitol is an important polyalcohol suitable for use in odontological, medical and pharmaceutical products and as an additive in food. The first studies on the efficacy of xylitol in the control and treatment of infections started in the late 1970s and it is still applied for this purpose, with safety and very little contribution to resistance. Xylitol seems to act against microorganisms exerting an anti-adherence effect. Some research studies have demonstrated its action against Gram-positive and Gram-negative bacteria and yeasts. However, a clear explanation of how xylitol is effective has not been completely established yet. Some evidence shows that xylitol acts on gene expression, down-regulating the ones which are involved in the microorganisms' virulence, such as capsule formation. Another possible clarification is that xylitol blocks lectin-like receptors. The most important aspect is that, over time, xylitol bypasses microbial resistance and succeeds in controlling infection, either alone or combined with another compound. In this review, the effect of xylitol in inhibiting the growth of a different microorganism is described, focusing on studies in which such an anti-adherent property was highlighted. This is the first mini-review to describe xylitol as an anti-adherent compound and take into consideration how it exerts such action.

  17. Hygienic quality control of chicken (thighs) by means of ionizing radiations

    International Nuclear Information System (INIS)

    Lescano, G.; Kairiyama, E.; Narvaiz, P.; Kaupert, N.L.

    1990-01-01

    High quality chicken thighs, packed in polystyrene trays covered with PVC films, were treated with ionizing energy provided by a semiindustrial 60 Co facility, with a dose of 2.5 kGy, at the temperature of melting ice. Control and irradiated samples were stored at 2 deg C ± 2 deg C and RH: 89 % ± 6 %. Microbiological, chemical and sensory evaluations were performed. This treatment improved significantly the hygienic quality of the product, and reduced in two log cycles the initial number of aerobic bacteria, which led to a 2.5 times extension of the commercialization period. A diminished water content was observed after irradiation. Decreasing values were also found in every sample as storage time went by; the irradiated sample, on day 23, had values 9 % lower than that of the control sample on day 2. Rancidity, measured as peroxide number, increased their values after irradiation, but in such extent that was not noticed organoleptically. It was never higher than 10 meg/kg of fat (specification of the Argentine Alimentary Codex for oils). The commercial quality of the irradiated samples was acceptable until day 22. (Author) [es

  18. [Internal audit in medical laboratory: what means of control for an effective audit process?].

    Science.gov (United States)

    Garcia-Hejl, Carine; Chianéa, Denis; Dedome, Emmanuel; Sanmartin, Nancy; Bugier, Sarah; Linard, Cyril; Foissaud, Vincent; Vest, Philippe

    2013-01-01

    To prepare the French Accreditation Committee (COFRAC) visit for initial certification of our medical laboratory, our direction evaluated its quality management system (QMS) and all its technical activities. This evaluation was performed owing an internal audit. This audit was outsourced. Auditors had an expertise in audit, a whole knowledge of biological standards and were independent. Several nonconformities were identified at that time, including a lack of control of several steps of the internal audit process. Hence, necessary corrective actions were taken in order to meet the requirements of standards, in particular, the formalization of all stages, from the audit program, to the implementation, review and follow-up of the corrective actions taken, and also the implementation of the resources needed to carry out audits in a pre-established timing. To ensure an optimum control of each step, the main concepts of risk management were applied: process approach, root cause analysis, effects and criticality analysis (FMECA). After a critical analysis of our practices, this methodology allowed us to define our "internal audit" process, then to formalize it and to follow it up, with a whole documentary system.

  19. Controlling hollow relativistic electron beam orbits with an inductive current divider

    Energy Technology Data Exchange (ETDEWEB)

    Swanekamp, S. B.; Richardson, A. S.; Angus, J. R.; Cooperstein, G.; Hinshelwood, D. D.; Ottinger, P. F.; Rittersdorf, I. M.; Schumer, J. W.; Weber, B. V.; Zier, J. C. [Plasma Physics Division, Naval Research Laboratory, Washington, DC 20375 (United States)

    2015-02-15

    A passive method for controlling the trajectory of an intense, hollow electron beam is proposed using a vacuum structure that inductively splits the beam's return current. A central post carries a portion of the return current (I{sub 1}), while the outer conductor carries the remainder (I{sub 2}). An envelope equation appropriate for a hollow electron beam is derived and applied to the current divider. The force on the beam trajectory is shown to be proportional to (I{sub 2}-I{sub 1}), while the average force on the envelope (the beam width) is proportional to the beam current I{sub b} = (I{sub 2} + I{sub 1}). The values of I{sub 1} and I{sub 2} depend on the inductances in the return-current path geometries. Proper choice of the return-current geometries determines these inductances and offers control over the beam trajectory. Solutions using realistic beam parameters show that, for appropriate choices of the return-current-path geometry, the inductive current divider can produce a beam that is both pinched and straightened so that it approaches a target at near-normal incidence with a beam diameter that is on the order of a few mm.

  20. Intensity and frequency stabilization of a laser diode by simultaneously controlling its temperature and current

    Science.gov (United States)

    Mu, Weiwei; Hu, Zhaohui; Wang, Jing; Zhou, Binquan

    2017-10-01

    Nuclear magnetic resonance gyroscope (NMRG) detects the angular velocity of the vehicle utilizing the interaction between the laser beam and the alkali metal atoms along with the noble gas atoms in the alkali vapor cell. In order to reach high precision inertial measurement target, semiconductor laser in NMRG should have good intensity and frequency stability. Generally, laser intensity and frequency are stabilized separately. In this paper, a new method to stabilize laser intensity and frequency simultaneously with double-loop feedback control is presented. Laser intensity is stabilized to the setpoint value by feedback control of laser diode's temperature. Laser frequency is stabilized to the Doppler absorption peak by feedback control of laser diode's current. The feedback control of current is a quick loop, hence the laser frequency stabilize quickly. The feedback control of temperature is a slow loop, hence the laser intensity stabilize slowly. With the feedback control of current and temperature, the laser intensity and frequency are stabilized finally. Additionally, the dependence of laser intensity and frequency on laser diode's current and temperature are analyzed, which contributes to choose suitable operating range for the laser diode. The advantage of our method is that the alkali vapor cell used for stabilizing laser frequency is the same one as the cell used for NMRG to operate, which helps to miniaturize the size of NMRG prototype. In an 8-hour continuous measurement, the long-term stability of laser intensity and frequency increased by two orders of magnitude and one order of magnitude respectively.

  1. Simultaneous real-time control of the current and pressure profiles in JET: experiments and modelling

    Energy Technology Data Exchange (ETDEWEB)

    Mazon, D.; Laborde, L.; Litaudon, X.; Moreau, D.; Zabeo, L.; Joffrin, E. [Association Euratom-CEA Cadarache (DSM/DRFC), 13 - Saint-Paul-lez-Durance (France). Dept. de Recherches sur la Fusion Controlee; Murari, A. [Consorzio RFX Association Euratom-ENEA, Padova (Italy); Ariola, M.; Albanese, R.; Tommasi, G. de; Pironti, A. [Association Euratom-ENEA, CREATE, Napoly (Italy); Moreau, D. [EFDA-JET CSU, Culham Science Centre, Abingdon, OX (United Kingdom); Tala, T. [Euratom-Tekes Association, VTT Processes (Finland); Crisanti, F.; Pericoli-Ridolfini, V.; Tuccillo, A. [Association Euratom-ENEA, C.R. Frascati (Italy); Baar, M. de; Vries, P. de [Euratom-FOM Association, TEC Cluster, Nieuwegein (Netherlands); De la Luna, E. [Euratom-Ciemat Association (Spain); Felton, R.; Corrigan, G. [Euratom-UKAEA Association, Culham Science Centre, Abingdon (United Kingdom)

    2004-07-01

    Real-time control of the plasma profiles (current density, pressure and flow) is one of the major issues for sustaining internal transport barriers (ITB) in a high performance plasma, with a large bootstrap current fraction. We have recently investigated the experimental and numerical aspects of the simultaneous control of the current and pressure profiles in JET ITB discharges. The current density and the electron temperature were successfully controlled via the safety factor profile (or via its inverse the tau-profile) and the {rho}{sup *}{sub Te} profile respectively. The results of these new studies are presented. With only a limited number of actuators, the technique aims at minimizing an integral square error signal which combines the 2 profiles, rather than attempting to control plasma parameters at some given radii with great precision. The resulting fuzziness of the control scheme allows the plasma to relax towards a physically accessible non-linear state which may not be accurately known in advance, but is close enough to the requested one to provide the required plasma performance. Closed loop experiments have allow to reach different target q and {rho}{sup *}{sub Te} profiles, and to some degree, to displace the region of maximum electron temperature gradient. The control has also shown some robustness in front of rapid transients.

  2. Elicitors as alternative strategy to pesticides in grapevine? Current knowledge on their mode of action from controlled conditions to vineyard.

    Science.gov (United States)

    Delaunois, Bertrand; Farace, Giovanni; Jeandet, Philippe; Clément, Christophe; Baillieul, Fabienne; Dorey, Stéphan; Cordelier, Sylvain

    2014-04-01

    Development and optimisation of alternative strategies to reduce the use of classic chemical inputs for protection against diseases in vineyard is becoming a necessity. Among these strategies, one of the most promising consists in the stimulation and/or potentiation of the grapevine defence responses by the means of elicitors. Elicitors are highly diverse molecules both in nature and origins. This review aims at providing an overview of the current knowledge on these molecules and will highlight their potential efficacy from the laboratory in controlled conditions to vineyards. Recent findings and concepts (especially on plant innate immunity) and the new terminology (microbe-associated molecular patterns, effectors, etc.) are also discussed in this context. Other objectives of this review are to highlight the difficulty of transferring elicitors use and results from the controlled conditions to the vineyard, to determine their practical and effective use in viticulture and to propose ideas for improving their efficacy in non-controlled conditions.

  3. Negative sequence current control in wind power plants with VSC-HVDC connection

    DEFF Research Database (Denmark)

    Chaudhary, Sanjay; Teodorescu, Remus; Rodriguez, Pedro

    2012-01-01

    Large offshore wind power plants may have multi-MW wind turbine generators (WTG) equipped with full-scale converters (FSC) and voltage source converter (VSC) based high voltaage direct-current (HVDC) transmission for grid connection. The power electronic converters in theWTG-FSC and the VSC......-HVDC allow fast current control in the offshore grid. This paper presents a method of controlling the negative sequence current injection into the offshore grid from the VSC-HVDC as well as WTG-FSCs. This would minimize the power oscillations and hence reduce the dc voltage overshoots in the VSC-HVDC system...... as well as in the WTG-FSCs; especially when the offshore grid is unbalanced due to asymmetric faults. The formulation for negative sequence current injection is mathematically derived and then implemented in electromagnetic transients (EMT) simulation model. The simulated results show that the negative...

  4. Securing a robust electrical discharge drilling process by means of flow rate control

    Science.gov (United States)

    Risto, Matthias; Munz, Markus; Haas, Ruediger; Abdolahi, Ali

    2017-10-01

    This paper deals with the increase of the process robustness while drilling cemented carbide using electrical discharge machining (EDM). A demand for high efficiency in the resulting diameter is equivalent with a high robustness of the EDM drilling process. Analysis were done to investigate the process robustness (standard deviation of the borehole diameter) when drilling cemented carbide. The investigation has shown that the dielectric flow rate changes over the drilling process. In this case the flow rate decreased with a shorter tool electrode due to an uneven wear of the tool electrode's cross section. Using a controlled flow rate during the drilling process has led to a reduced standard deviation of the borehole diameter, thus to a higher process robustness when drilling cemented carbide.

  5. Applied means to increase stimulation in the control room work at the Swedish nuclear power plants

    International Nuclear Information System (INIS)

    Blomberg, P.E.; Akerhielm, F.

    1988-01-01

    Nuclear power plants are generally designed and built with a quality which implies that the units seldom require intervention from the operating staff under normal operating conditions. This leaves the operators with the dominating task of only passively supervising the process. A number of measures have been taken to counteract the problem of under-stimulated individuals in the control rooms and to maintain active and purposeful working conditions. Basically these measures derive from the belief that augmented competence, increased responsibilities and a enhanced sense of indispensability functions as an inspiration even in a monotonous working situation. For this purpose a number of activities and tasks, parallel to the normal duties as member of the operating staff, have been implemented

  6. Video flow active control by means of adaptive shifted foveal geometries

    Science.gov (United States)

    Urdiales, Cristina; Rodriguez, Juan A.; Bandera, Antonio J.; Sandoval, Francisco

    2000-10-01

    This paper presents a control mechanism for video transmission that relies on transmitting non-uniform resolution images depending on the delay of the communication channel. These images are built in an active way to keep the areas of interest of the image at the highest resolution available. In order to shift the area of high resolution over the image and to achieve a data structure easy to process by using conventional algorithms, a shifted fovea multi resolution geometry of adaptive size is used. Besides, if delays are nevertheless too high, the different areas of resolution of the image can be transmitted at different rates. A functional system has been developed for corridor surveillance with static cameras. Tests with real video images have proven that the method allows an almost constant rate of images per second as long as the channel is not collapsed.

  7. Control of a hydraulic system by means of a fuzzy approach

    Directory of Open Access Journals (Sweden)

    Mohamed Ksantini

    2013-07-01

    Full Text Available Non linear models can be represented conveniently by Takagi-Sugeno fuzzy models when nonlinearities are bounded. This approach uses a collection of linear models which are interpolated by non linear functions. Then the global control law is the interpolation by the same functions of each feedback associated to each linear model. A Lyapunov approach enables to compute these feedback gains. The number of linear models depends directly on the number of nonlinearities the system has. The more models there are, the more difficult it is to guarantee the stability of the closed loop. This paper proposes a method to reduce the number of linear models by assuming a number of nonlinearities considered as uncertainties and to guarantee the global exponential stability of the system. This method is applied on a hydraulic system.

  8. Conditions for settling liquid levels by means of gamma-ray relay control

    Energy Technology Data Exchange (ETDEWEB)

    Wakabayashi, N [Kobe Univ. (Japan). Faculty of Engineering

    1976-03-01

    Using a control action which consists of infusion and exhaust at constant speeds and a neutral zone to maintain liquid levels within a given range, a gamma-ray source, a detector, and two relays at the upper and lower limits of the counting rate were provided. The optimum condition in this case is discussed and confirmed experimentally. Since a counting rate-meter has a time constant and its output is subject to the statistical fluctuation, the liquid level may overrun the opposite limit, move again after settling within the range, or drift far out of the range by a load before actuation of the relay. Formulas are derived providing the conditions such that these phenomena will not occur more frequently than a tolerant probability. These give the relations between the counting rates at the upper and lower limits, the time constant of the rate-meter, the multipliers of the standard deviations of the counting rates, the infusing and exhausting speeds, and the hysteresis widths of the limiting relays. Since it can be said that the first two of the five quantities should be smaller and the next two greater, the optimum condition can be determined from the formulas. When the infusing and exhausting speeds are the same and the hysteresis widths are equal, the formulas show that the optimum is a case where the ratio of the counting rates at the two limits, which is taken smaller than unity, is small, and where each hysteresis width is equal to 0.34 times the difference between the two counting rates, almost regardless of the value of their ratio. The above-mentioned deductions were examined in a system constructed with a backscattered gamma-ray type level gauge and a controller for infusion and exhaust of water. Its results almost agreed with those of the deductions when the multipliers of the standard deviations are substituted for by 2.

  9. Control of the Superconducting Magnets current Power Supplies of the TJ-II Gyrotrons

    International Nuclear Information System (INIS)

    Ros, A.; Fernandez, A.; Tolkachev, A.; Catalan, G.

    2006-01-01

    The TJ-II ECRH heating system consists of two gyrotrons, which can deliver a maximum power of 300 kW at a frequency of 53.2 GHz. Another 28 GHz gyrotron is going to be used in the Bernstein waves heating system. In order to get the required frequency, the gyrotrons need and homogeneous magnetic field of several tesla, which is generated by a superconducting coil field by a current source. This document describes the current source control as well as the high precision ammeters control. These ammeters measure the current in the superconducting coils. The user interface and the programming of the control system are described. The communication between devices is also explained. (author) 9 Refs

  10. A maximum power point tracking for photovoltaic-SPE system using a maximum current controller

    Energy Technology Data Exchange (ETDEWEB)

    Muhida, Riza [Osaka Univ., Dept. of Physical Science, Toyonaka, Osaka (Japan); Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Park, Minwon; Dakkak, Mohammed; Matsuura, Kenji [Osaka Univ., Dept. of Electrical Engineering, Suita, Osaka (Japan); Tsuyoshi, Akira; Michira, Masakazu [Kobe City College of Technology, Nishi-ku, Kobe (Japan)

    2003-02-01

    Processes to produce hydrogen from solar photovoltaic (PV)-powered water electrolysis using solid polymer electrolysis (SPE) are reported. An alternative control of maximum power point tracking (MPPT) in the PV-SPE system based on the maximum current searching methods has been designed and implemented. Based on the characteristics of voltage-current and theoretical analysis of SPE, it can be shown that the tracking of the maximum current output of DC-DC converter in SPE side will track the MPPT of photovoltaic panel simultaneously. This method uses a proportional integrator controller to control the duty factor of DC-DC converter with pulse-width modulator (PWM). The MPPT performance and hydrogen production performance of this method have been evaluated and discussed based on the results of the experiment. (Author)

  11. Current phase control test based on real-time measurement of impedance matrix of ICRF antennas

    Energy Technology Data Exchange (ETDEWEB)

    Saito, K., E-mail: saito@nifs.ac.jp [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan); Kumazawa, R.; Seki, T.; Kasahara, H.; Yokota, M.; Nomura, G.; Shimpo, F.; Mutoh, T. [National Institute for Fusion Science, Toki, Gifu 509-5292 (Japan)

    2011-10-15

    New ion cyclotron range of frequencies (ICRF) antennas have just been installed in the large helical device (LHD). These side-by-side ICRF antennas are symmetrical and designed to launch fast waves with various wave numbers parallel to the magnetic field line. The wave number can be controlled by changing the current phase on the straps; however, the mutual coupling between antennas changes antenna impedances, even if the plasma parameters are constant, leading to an increase in the reflected power. In addition to the current phase control, impedance matching devices must be tuned for the protection of tetrode tubes and efficient power injection. For this purpose, the impedance matrix of ICRF antennas must be determined, and it can be deduced from the forward and reflected waves at the outlet of the power amplifier by assuming geometric symmetry and reciprocity of the antennas. Using half-scale antennas, we successfully demonstrated simultaneous impedance matching and current phase control.

  12. A sensorless control method for capacitor voltage balance and circulating current suppression of modular multilevel converter

    DEFF Research Database (Denmark)

    Liu, Hui; Ma, Ke; Loh, Poh Chiang

    2015-01-01

    There are several problems in the Modular Multilevel Converter (MMC), such as the appearance of circulating current, capacitor voltage unbalance and the requirement for a high number of sensors. All these problems will decrease the reliability and raise the cost/uncertainty of using MMC solutions....... As a result, a sensorless control method is proposed in this paper, which targets to improve the performances of MMC in respect to the above mentioned disadvantages: To decrease the cost and simplify the physical implementation, a state observer is proposed and designed to estimate both the capacitor voltages...... and the circulating currents in order to replace the high numbers of sensors. Furthermore, a control method combining the circulating current suppression and the capacitor voltage balancing is conducted based on the proposed state observer. It is concluded that the proposed state observer and control method can...

  13. Control of a three-dimensional turbulent shear layer by means of oblique vortices

    Science.gov (United States)

    Jürgens, Werner; Kaltenbach, Hans-Jakob

    2018-04-01

    The effect of local forcing on the separated, three-dimensional shear layer downstream of a backward-facing step is investigated by means of large-eddy simulation for a Reynolds number based on the step height of 10,700. The step edge is either oriented normal to the approaching turbulent boundary layer or swept at an angle of 40°. Oblique vortices with different orientation and spacing are generated by wavelike suction and blowing of fluid through an edge parallel slot. The vortices exhibit a complex three-dimensional structure, but they can be characterized by a wavevector in a horizontal section plane. In order to determine the step-normal component of the wavevector, a method is developed based on phase averages. The dependence of the wavevector on the forcing parameters can be described in terms of a dispersion relation, the structure of which indicates that the disturbances are mainly convected through the fluid. The introduced vortices reduce the size of the recirculation region by up to 38%. In both the planar and the swept case, the most efficient of the studied forcings consists of vortices which propagate in a direction that deviates by more than 50° from the step normal. These vortices exhibit a spacing in the order of 2.5 step heights. The upstream shift of the reattachment line can be explained by increased mixing and momentum transport inside the shear layer which is reflected in high levels of the Reynolds shear stress -ρ \\overline{u'v'}. The position of the maximum of the coherent shear stress is found to depend linearly on the wavelength, similar to two-dimensional free shear layers.

  14. Sawtooth control by on-axis electron cyclotron current drive on the WT-3 tokamak

    International Nuclear Information System (INIS)

    Asakawa, M.; Tanabe, K.; Nakayama, A.; Watanabe, M.; Nakamura, M.; Tanaka, H.; Maekawa, T.; Terumichi, Y.

    1999-01-01

    The experiments on control of sawtooth oscillations (STO) by electron cyclotron current drive (ECCD) have been performed on the WT-3 tokamak. Stabilization and excitation of STO are observed for counter-ECCD and co-ECCD, respectively, when the position of the power deposition is located inside the inversion radius. These results are due to the modification of the current profile near the magnetic axis. (author)

  15. Real-time control of current and pressure profiles in tokamak plasmas

    International Nuclear Information System (INIS)

    Laborde, L.

    2005-12-01

    Recent progress in the field of 'advanced tokamak scenarios' prefigure the operation regime of a future thermonuclear fusion power plant. Compared to the reference regime, these scenarios offer a longer plasma confinement time thanks to increased magnetohydrodynamic stability and to a better particle and energy confinement through a reduction of plasma turbulence. This should give access to comparable fusion performances at reduced plasma current and could lead to a steady state fusion reactor since the plasma current could be entirely generated non-inductively. Access to this kind of regime is provided by the existence of an internal transport barrier, linked to the current profile evolution in the plasma, which leads to steep temperature and pressure profiles. The comparison between heat transport simulations and experiments allowed the nature of the barriers to be better understood as a region of strongly reduced turbulence. Thus, the control of this barrier in a stationary manner would be a remarkable progress, in particular in view of the experimental reactor ITER. The Tore Supra and JET tokamaks, based in France and in the United Kingdom, constitute ideal instruments for such experiments: the first one allows stationary plasmas to be maintained during several minutes whereas the second one provides unique fusion performances. In Tore Supra, real-time control experiments have been accomplished where the current profile width and the pressure profile gradient were controlled in a stationary manner using heating and current drive systems as actuators. In the JET tokamak, the determination of an empirical static model of the plasma allowed the current and pressure profiles to be simultaneously controlled and so an internal transport barrier to be sustained. Finally, the identification of a dynamic model of the plasma led to the definition of a new controller capable, in principle, of a more efficient control. (author)

  16. Electric control of emergent magnonic spin current and dynamic multiferroicity in magnetic insulators at finite temperatures

    Science.gov (United States)

    Wang, Xi-guang; Chotorlishvili, L.; Guo, Guang-hua; Berakdar, J.

    2018-04-01

    Conversion of thermal energy into magnonic spin currents and/or effective electric polarization promises new device functionalities. A versatile approach is presented here for generating and controlling open circuit magnonic spin currents and an effective multiferroicity at a uniform temperature with the aid of spatially inhomogeneous, external, static electric fields. This field applied to a ferromagnetic insulator with a Dzyaloshinskii-Moriya type coupling changes locally the magnon dispersion and modifies the density of thermally excited magnons in a region of the scale of the field inhomogeneity. The resulting gradient in the magnon density can be viewed as a gradient in the effective magnon temperature. This effective thermal gradient together with local magnon dispersion result in an open-circuit, electric field controlled magnonic spin current. In fact, for a moderate variation in the external electric field the predicted magnonic spin current is on the scale of the spin (Seebeck) current generated by a comparable external temperature gradient. Analytical methods supported by full-fledge numerics confirm that both, a finite temperature and an inhomogeneous electric field are necessary for this emergent non-equilibrium phenomena. The proposal can be integrated in magnonic and multiferroic circuits, for instance to convert heat into electrically controlled pure spin current using for example nanopatterning, without the need to generate large thermal gradients on the nanoscale.

  17. Current-Loop Control for the Pitching Axis of Aerial Cameras via an Improved ADRC

    Directory of Open Access Journals (Sweden)

    BingYou Liu

    2017-01-01

    Full Text Available An improved active disturbance rejection controller (ADRC is designed to eliminate the influences of the current-loop for the pitching axis control system of an aerial camera. The improved ADRC is composed of a tracking differentiator (TD, an improved extended state observer (ESO, an improved nonlinear state error feedback (NLSEF, and a disturbance compensation device (DCD. The TD is used to arrange transient process. The improved ESO is utilized to observe the state extended by nonlinear dynamics, model uncertainty, and external disturbances. Overtime variation of the current-loop can be predicted by the improved ESO. The improved NLSEF is adopted to restrain the residual errors of the current-loop. The DCD is used to compensate the overtime variation of the current-loop in real time. The improved ADRC is designed based on a new nonlinear function newfal(·. This function exhibits enhanced continuity and smoothness compared to previously available nonlinear functions. Thus, the new nonlinear function can effectively decrease the high-frequency flutter phenomenon. The improved ADRC exhibits improved control performance, and disturbances of the current-loop can be eliminated by the improved ADRC. Finally, simulation experiments are performed. Results show that the improved ADRC displayed better performance than the proportional integral (PI control strategy and traditional ADRC.

  18. Distributed Cooperative Current-Sharing Control of Parallel Chargers Using Feedback Linearization

    Directory of Open Access Journals (Sweden)

    Jiangang Liu

    2014-01-01

    Full Text Available We propose a distributed current-sharing scheme to address the output current imbalance problem for the parallel chargers in the energy storage type light rail vehicle system. By treating the parallel chargers as a group of agents with output information sharing through communication network, the current-sharing control problem is recast as the consensus tracking problem of multiagents. To facilitate the design, input-output feedback linearization is first applied to transform the nonidentical nonlinear charging system model into the first-order integrator. Then, a general saturation function is introduced to design the cooperative current-sharing control law which can guarantee the boundedness of the proposed control. The cooperative stability of the closed-loop system under fixed and dynamic communication topologies is rigorously proved with the aid of Lyapunov function and LaSalle invariant principle. Simulation using a multicharging test system further illustrates that the output currents of parallel chargers are balanced using the proposed control.

  19. A current controller of grid-connected converter for harmonic damping in a distribution network

    DEFF Research Database (Denmark)

    Wang, Xiongfei; Blaabjerg, Frede; Chen, Zhe

    2011-01-01

    Harmonic resonance caused by the increased use of shunt-connected capacitors in LCL-filters and power factor correction devices may become a serious power quality challenge in electric distribution systems. A voltage-detection method based on current control is developed to damp harmonic resonances....... However, it is susceptible to the mismatch between harmonic conductance and characteristic impedance of distribution feeder. This paper proposes a current controller which allows discrete adjustment of harmonic conductance for both the characteristic harmonic and the non-characteristic harmonic voltages...

  20. Low Voltage CMOS Fully Differential Current Feedback Amplifier with Controllable 3-dB Bandwidth

    International Nuclear Information System (INIS)

    Madian, A.H.; Mahmoud, S.A.; Ashour, M.A.; Soliman, A.M.

    2008-01-01

    This paper presents a new CMOS fully differential current feedback operational amplifier with controllable 3-dB bandwidth suitable for analog data processing and acquisition applications. The FDCFOA has the advantage of a wide range controllable 3-dB bandwidth (∼57 MHz to 500 MHz) without changing the feedback resistance this guarantee the stability of the circuit. The FDCFOA has a standby current of 320μA. PSpice simulations of the FDCFOA block were given using 0.25μm CMOS technology from AMI MOSIS and dual supply voltages ±0.75 V

  1. Eddy-current inspection of high flux isotope reactor nuclear control rods

    International Nuclear Information System (INIS)

    Smith, J.H.; Chitwood, L.D.

    1981-07-01

    Inner control rods for the High Flux Isotope Reactor were nondestructively inspected for defects by eddy-current techniques. During these examinations aluminum cladding thickness and oxide thickness on the cladding were also measured. Special application techniques were required because of the high-radiation levels (approx. 10 5 R/h at 30 cm) present and the relatively large temperature gradients that occurred on the surface of the control rods. The techniques used to perform the eddy-current inspections and the methods used to reduce the associated data are described

  2. Current control loop design and analysis based on resonant regulators for microgrid applications

    DEFF Research Database (Denmark)

    Federico, de Bosio; Pastorelli, Michelle; de Sousa Ribeiro, Luiz Antonio

    2015-01-01

    Voltage and current control loops play an important role in the performance of microgrids employing power electronics voltage source inverters. Correct design of feedback loops is essential for the proper operation of these systems. This paper analyzes the influence of state feedback cross......-coupling in the design of resonant regulators for inner current loops in power converters operating in standalone microgrids. It is also demonstrated that the effect of state feedback cross-coupling degrades the performance of the control loops by increasing the steady-state error. Different resonant regulators...

  3. Grid-Current-Feedback Control for LCL-Filtered Grid Converters With Enhanced Stability

    DEFF Research Database (Denmark)

    Xin, Zhen; Wang, Xiongfei; Loh, Poh Chiang

    2017-01-01

    This paper proposes a Second-Order-Generalized- Integrator (SOGI)-based time delay compensation method for extending the stable region of dual-loop Grid-Current-Feedback (GCF) control system. According to the analysis, stable region of the dual-loop system should be designed below a certain...... critical frequency, before time delay compensation method can be applied. To always meet the requirement, relationship between single-loop converter-current-feedback and dual-loop GCF control is clarified, before a robust inner-loop gain for the dualloop GCF scheme is determined. Enforcing this gain allows...

  4. Gasohol Quality Control for Real Time Applications by Means of a Multimode Interference Fiber Sensor

    Science.gov (United States)

    Rodríguez Rodríguez, Adolfo J.; Baldovino-Pantaleón, Oscar; Domínguez Cruz, Rene F.; Zamarreño, Carlos R.; Matías, Ignacio R.; May-Arrioja, Daniel A.

    2014-01-01

    In this work we demonstrate efficient quality control of a variety of gasoline and ethanol (gasohol) blends using a multimode interference (MMI) fiber sensor. The operational principle relies on the fact that the addition of ethanol to the gasohol blend reduces the refractive index (RI) of the gasoline. Since MMI sensors are capable of detecting small RI changes, the ethanol content of the gasohol blend is easily determined by tracking the MMI peak wavelength response. Gasohol blends with ethanol contents ranging from 0% to 50% has been clearly identified using this device, which provides a linear response with a maximum sensitivity of 0.270 nm/% EtOH. The sensor can also distinguish when water incorporated in the blend has exceeded the maximum volume tolerated by the gasohol blend, which is responsible for phase separation of the ethanol and gasoline and could cause serious engine failures. Since the MMI sensor is straightforward to fabricate and does not require any special coating it is a cost effective solution for real time and in-situ monitoring of the quality of gasohol blends. PMID:25256111

  5. Gasohol Quality Control for Real Time Applications by Means of a Multimode Interference Fiber Sensor

    Directory of Open Access Journals (Sweden)

    Adolfo J. Rodríguez Rodríguez

    2014-09-01

    Full Text Available In this work we demonstrate efficient quality control of a variety of gasoline and ethanol (gasohol blends using a multimode interference (MMI fiber sensor. The operational principle relies on the fact that the addition of ethanol to the gasohol blend reduces the refractive index (RI of the gasoline. Since MMI sensors are capable of detecting small RI changes, the ethanol content of the gasohol blend is easily determined by tracking the MMI peak wavelength response. Gasohol blends with ethanol contents ranging from 0% to 50% has been clearly identified using this device, which provides a linear response with a maximum sensitivity of 0.270 nm/% EtOH. The sensor can also distinguish when water incorporated in the blend has exceeded the maximum volume tolerated by the gasohol blend, which is responsible for phase separation of the ethanol and gasoline and could cause serious engine failures. Since the MMI sensor is straightforward to fabricate and does not require any special coating it is a cost effective solution for real time and in-situ monitoring of the quality of gasohol blends.

  6. Design of current controller of grid-connected voltage source converter based internal model control in wind power

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Xianping; Guo Jindong; Xu Honghua [Inst. of Electrical Engineering, Chinese Academy of Sciences, BJ (China)

    2008-07-01

    Grid-connected voltage source converter (VSC) is important for variable speed turbines with doubly fed induction generator (DFIG), and bad performance of current loop of VSC may cause VSC inject much low and high order harmonics into grid. Therefore, design of current controller of VSC is very important. PI regulator is often used to regulate current error in dq rotating coordinate to obtain zero steady error. However, it is complex to design PI parameters, and researchers need many trial-and-error steps. Therefore, a novel and simple design method of PI regulator for grid-connected VSC, which is based internal model control (IMC), has been presented in this paper. The parameters of PI regulator can be expressed directly with certain L-type line filter parameters and the desired closed-loop bandwidth. At last, The simulation has been done and result shows that the method in this paper is easy and useful to regulate PI parameters. (orig.)

  7. Controlling Confinement with Induced Toroidal Current in the Flexible Heliac TJ-II

    Energy Technology Data Exchange (ETDEWEB)

    Romero, J A; Lopez-Bruna, D; Lopez-Fraguas, A; Ascasibar, E; TJ-II Team

    2002-07-01

    A method to control plasma particle an energy confinement in the TJ-II Heliac devices is reported A small toroidal current is induced in the plasma with the aid of a 0.2 Wb air core transformer. Plasma particle and energy confinement improve (degrade) with negative (positive) plasma current. For typical TJ-II discharges plasma density and temperature broaden considerably when plasma current is sufficiently negative, accounting for a 40% increase in stored energy. The experimental results agree qualitatively with the paradigm of instability growth rate modifications with magnetic shear. (Author) 18 refs.

  8. Controlling Confinement with Induced Toroidal Current in the Flexible Heliac TJ-II

    International Nuclear Information System (INIS)

    Romero, J. A.; Lopez-Bruna, D.; Lopez-Fraguas, A.; Ascasibar, E.; TJ-II Team

    2002-01-01

    A method to control plasma particle an energy confinement in the TJ-II Heliac devices is reported A small toroidal current is induced in the plasma with the aid of a 0.2 Wb air core transformer. Plasma particle and energy confinement improve (degrade) with negative (positive) plasma current. For typical TJ-II discharges plasma density and temperature broaden considerably when plasma current is sufficiently negative, accounting for a 40% increase in stored energy. The experimental results agree qualitatively with the paradigm of instability growth rate modifications with magnetic shear. (Author) 18 refs

  9. Theory and experiments on RF plasma heating, current drive and profile control in TORE SUPRA

    International Nuclear Information System (INIS)

    Moreau, D.

    1994-01-01

    This paper reviews the main experimental and theoretical achievements related to the study of RF heating and non-inductive current drive and particularly phenomena related to the current density profile control and the potentiality of producing stationary enhanced performance regimes: description of the Lower Hybrid (LH) and Ion Cyclotron Resonant Frequency (ICRF) systems; long pulse coupling performance of the RF systems; observation of the transition to the so-called ''stationary LHEP regime'' in which the (flat) central current density and (peaked) electron temperature profiles are fully decoupled; experiments on ICRF sawtooth stabilization with the combined effect of LHCD modifying the current density profile; diffusion of fast electrons generated by LH waves; ramp-up experiments in which the LH power provided a significant part of the resistive poloidal flux and flux consumption scaling; theory of spectral wave diffusion and multipass absorption; fast wave current drive modelling with the Alcyon full wave code; a reflector LH antenna concept. 18 figs., 48 refs

  10. Current-controlled light scattering and asymmetric plasmon propagation in graphene

    Science.gov (United States)

    Wenger, Tobias; Viola, Giovanni; Kinaret, Jari; Fogelström, Mikael; Tassin, Philippe

    2018-02-01

    We demonstrate that plasmons in graphene can be manipulated using a dc current. A source-drain current lifts the forward/backward degeneracy of the plasmons, creating two modes with different propagation properties parallel and antiparallel to the current. We show that the propagation length of the plasmon propagating parallel to the drift current is enhanced, while the propagation length for the antiparallel plasmon is suppressed. We also investigate the scattering of light off graphene due to the plasmons in a periodic dielectric environment and we find that the plasmon resonance separates in two peaks corresponding to the forward and backward plasmon modes. The narrower linewidth of the forward propagating plasmon may be of interest for refractive index sensing and the dc current control could be used for the modulation of mid-infrared electromagnetic radiation.

  11. MISO Current-mode Biquad Filter with Independent Control of Pole Frequency and Quality Factor

    Directory of Open Access Journals (Sweden)

    W. Jaikla

    2012-09-01

    Full Text Available This article presents a three-inputs single-output biquadratic filter performing completely standard functions: low-pass, high-pass, band-pass, band-reject and all-pass functions, based on current controlled current conveyor transconductance amplifier (CCCCTA. The quality factor and pole frequency can be electronically/independently tuned via the input bias current. The proposed circuit uses 2 CCCCTAs and 2 grounded capacitors without external any resistors which is very suitable to further develop into an integrated circuit. The filter does not require double input current signal. Each function response can be selected by suitably selecting input signals with digital method. Moreover, the circuit possesses high output impedance which would be an ideal choice for current-mode cascading. The PSPICE simulation results are included to verify the workability of the proposed filter. The given results agree well with the theoretical anticipation.

  12. Multi-Objective Predictive Balancing Control of Battery Packs Based on Predictive Current

    Directory of Open Access Journals (Sweden)

    Wenbiao Li

    2016-04-01

    Full Text Available Various balancing topology and control methods have been proposed for the inconsistency problem of battery packs. However, these strategies only focus on a single objective, ignore the mutual interaction among various factors and are only based on the external performance of the battery pack inconsistency, such as voltage balancing and state of charge (SOC balancing. To solve these problems, multi-objective predictive balancing control (MOPBC based on predictive current is proposed in this paper, namely, in the driving process of an electric vehicle, using predictive control to predict the battery pack output current the next time. Based on this information, the impact of the battery pack temperature caused by the output current can be obtained. Then, the influence is added to the battery pack balancing control, which makes the present degradation, temperature, and SOC imbalance achieve balance automatically due to the change of the output current the next moment. According to MOPBC, the simulation model of the balancing circuit is built with four cells in Matlab/Simulink. The simulation results show that MOPBC is not only better than the other traditional balancing control strategies but also reduces the energy loss in the balancing process.

  13. Rectifier Current Control for an LLC Resonant Converter Based on a Simplified Linearized Model

    Directory of Open Access Journals (Sweden)

    Zhijian Fang

    2018-03-01

    Full Text Available In this paper, a rectifier current control for an LLC resonant converter is proposed, based on a simplified, two-order, linearized model that adds a rectifier current feedback inner loop to improve dynamic performance. Compared to the traditional large-signal model with seven resonant states, this paper utilizes a rectifier current state to represent the characteristics of the resonant states, simplifying the LLC resonant model from seven orders to two orders. Then, the rectifier current feedback inner loop is proposed to increase the control system damping, improving dynamic performance. The modeling and design methodology for the LLC resonant converter are also presented in this paper. A frequency analysis is conducted to verify the accuracy of the simplified model. Finally, a 200 W LLC resonant converter prototype is built to verify the effectiveness of the proposed control strategy. Compared to a traditional single-loop controller, the settling time and voltage droop were reduced from 10.8 ms to 8.6 ms and from 6.8 V to 4.8 V, respectively, using the proposed control strategy.

  14. 3D morphological analysis of copper foams as current collectors for Li-ion batteries by means of X-ray tomography

    Energy Technology Data Exchange (ETDEWEB)

    Etiemble, A. [Institut National des Sciences Appliquées de Lyon, Laboratoire MATEIS, F-69621 Villeurbanne (France); Institut National de la Recherche Scientifique – Centre Énergie, Matériaux, Télécommunications, Varennes, Québec J3X 1S2 (Canada); Adrien, J. [Institut National des Sciences Appliquées de Lyon, Laboratoire MATEIS, F-69621 Villeurbanne (France); Maire, E., E-mail: eric.maire@insa-lyon.fr [Institut National des Sciences Appliquées de Lyon, Laboratoire MATEIS, F-69621 Villeurbanne (France); Idrissi, H. [Institut National des Sciences Appliquées de Lyon, Laboratoire MATEIS, F-69621 Villeurbanne (France); Reyter, D. [Institut National de la Recherche Scientifique – Centre Énergie, Matériaux, Télécommunications, Varennes, Québec J3X 1S2 (Canada); Roué, L., E-mail: roue@emt.inrs.ca [Institut National de la Recherche Scientifique – Centre Énergie, Matériaux, Télécommunications, Varennes, Québec J3X 1S2 (Canada)

    2014-09-15

    Highlights: • X-ray tomography analysis of open-cell copper foams is performed. • The effect of a dissolution treatment on the foam morphology is highlighted. • The interest of such Cu foams as current collectors for Li-ion batteries is discussed. - Abstract: As-received and chemically treated copper foams were characterized by means of laboratory X-ray tomography with a resolution of 0.5 μm. 3D image processing and analysis allowed the morphological parameters (size, sphericity, tortuosity etc.) of the pores and copper skeleton to be determined. The chemical dissolution of the Cu foam in an acid hydrogen peroxide solution results in an increase of the open pore size (from 54 to 93 μm) and a decrease of the foam thickness (from 140 to 115 μm). With an open porosity of 81.8% and a specific surface area as high as 280,000 (49,000) m{sup 2}/m{sup 3} of Cu (foam), the chemically-treated Cu foam appears very attractive for use as a 3D current collector for metal (e.g. Si) based anodes for Li-ion batteries.

  15. The Current Status of Baculovirus and Their Implication for Insect Pest Control

    Directory of Open Access Journals (Sweden)

    Arman Wijonarko

    2001-07-01

    Full Text Available Baculovirus have been promoted as the promising bioinsecticides for their pest control potential for more than half a century. But only a few have been successful as biological control agent, and almost none has been proven as commercial success, or widely used for large-scale insect pest control. The bioinsecticides currently represent only a small fraction of the world pesticide market. The successful of the Bt crop marked a special achievement in the bioinsecticide market growth. How about the baculoviruses? The main hurdle for baculovirus to be developed as bioinsecticide is its poor performance compare to synthetic chemical ones, include the speed of kill, and host range. It is important to understand the nature of baculovirus, and explore the possibilities to develop new way in applying the baculovirus as bioinsecticides. Key words: current status, baculovirus, insect control

  16. A GPS-Based Control Framework for Accurate Current Sharing and Power Quality Improvement in Microgrids

    DEFF Research Database (Denmark)

    Golsorkhi, Mohammad; Savaghebi, Mehdi; Lu, Dylan

    2017-01-01

    This paper proposes a novel hierarchical control strategy for improvement of load sharing and power quality in ac microgrids. This control framework is composed of a droop based controller at the primary level, and a combination of distributed power sharing and voltage conditioning schemes...... consensus protocol to ensure proportional sharing of average power. The voltage conditioning scheme produces compensation signals at fundamental and dominant harmonics to improve the voltage quality at a sensitive load bus. Experimental results are presented to validate the efficacy of the proposed method....... dynamic response. The droop coefficient, which acts as a virtual resistance is adaptively changed as a function of the peak current. This strategy not only simplifies the control design but also improves the current sharing accuracy at high loading conditions. The distributed power sharing scheme uses...

  17. Analysis of Steady-State Error in Torque Current Component Control of PMSM Drive

    Directory of Open Access Journals (Sweden)

    BRANDSTETTER, P.

    2017-05-01

    Full Text Available The paper presents dynamic properties of a vector controlled permanent magnet synchronous motor drive supplied by a voltage source inverter. The paper deals with a control loop for the torque producing stator current. There is shown fundamental mathematical description for the vector control structure of the permanent magnet synchronous motor drive with respect to the current control for d-axis and q-axis of the rotor rotating coordinate system. The derivations of steady-state deviation for schemes with and without decoupling circuits are described for q-axis. The properties of both schemes are verified by MATLAB-SIMULINK program considering a lower and a higher value of inertia and by experimental measurements in our laboratory. The simulation and experimental results are presented and discussed at the end of the paper.

  18. Optimising the operation of hybrid coolers by means of efficient control equipment; Optimierung der Betriebsweise von Hybridkuehlern durch effiziente Steuerungstechnik

    Energy Technology Data Exchange (ETDEWEB)

    Odrich, T.; Koenig, H. [Jaeggi/Guentner (Schweiz) AG, Trimbach (Switzerland)

    2007-07-01

    Due to its functional principle and design, the hybrid dry cooler holds a high potential for saving water and energy. Purely convective heat discharge during dry operation in the case of a high annual rate of utilisation, evaporative cooling during the wetting cycle at peak load times or high ambient temperatures and infinitely adjustable fan speed in both operating modes permit a very substantial recooling performance at low operating costs and with little space requirement. However, the efficiency of hybrid dry coolers depends to a large degree on how intelligently the cooling functions are controlled and on the control strategy. The present article demonstrates that the control strategy contributes decisively to minimising water and energy consumption and costs. Besides describing the actual functions of a hybrid cooler control system it presents a control strategy for automatic lowering of the setpoint and hence optimisation of the refrigeration process. It discusses the option of operating multiple hybrid coolers by means of a hydraulic network and presents an optimised control concept for this purpose which is based on a master control unit. In conclusion the study shows that hybrid coolers need their own optimised control unit if maximum savings in energy and water are to be achieved.

  19. Bioethics Symposium: The ethical food movement: What does it mean for the role of science and scientists in current debates about animal agriculture?

    Science.gov (United States)

    Croney, C C; Apley, M; Capper, J L; Mench, J A; Priest, S

    2012-05-01

    Contemporary animal agriculture is increasingly criticized on ethical grounds. Consequently, current policy and legislative discussions have become highly controversial as decision makers attempt to reconcile concerns about the impacts of animal production on animal welfare, the environment, and on the efficacy of antibiotics required to ensure human health with demands for abundant, affordable, safe food. Clearly, the broad implications for US animal agriculture of what appears to be a burgeoning movement relative to ethical food production must be understood by animal agriculture stakeholders. The potential effects of such developments on animal agricultural practices, corporate marketing strategies, and public perceptions of the ethics of animal production must also be clarified. To that end, it is essential to acknowledge that people's beliefs about which food production practices are appropriate are tied to diverse, latent value systems. Thus, relying solely on scientific information as a means to resolve current debates about animal agriculture is unlikely to be effective. The problem is compounded when scientific information is used inappropriately or strategically to advance a political agenda. Examples of the interface between science and ethics in regards to addressing currently contentious aspects of food animal production (animal welfare, antimicrobial use, and impacts of animal production practices on the environment) are reviewed. The roles of scientists and science in public debates about animal agricultural practices are also examined. It is suggested that scientists have a duty to contribute to the development of sound policy by providing clear and objectively presented information, by clarifying misinterpretations of science, and by recognizing the differences between presenting data vs. promoting their own value judgments in regard to how and which data should be used to establish policy. Finally, the role of the media in shaping public opinions

  20. Station-keeping control of an unmanned surface vehicle exposed to current and wind disturbances

    OpenAIRE

    Sarda, Edoardo I.; Qu, Huajin; Bertaska, Ivan R.; von Ellenrieder, Karl D.

    2017-01-01

    Field trials of a 4 meter long, 180 kilogram, unmanned surface vehicle (USV) have been conducted to evaluate the performance of station-keeping heading and position controllers in an outdoor marine environment disturbed by wind and current. The USV has a twin hull configuration and a custom-designed propulsion system, which consists of two azimuthing thrusters, one for each hull. Nonlinear proportional derivative, backstepping and sliding mode feedback controllers were tested in winds of abou...

  1. Application of drive circuit based on L298N in direct current motor speed control system

    Science.gov (United States)

    Yin, Liuliu; Wang, Fang; Han, Sen; Li, Yuchen; Sun, Hao; Lu, Qingjie; Yang, Cheng; Wang, Quanzhao

    2016-10-01

    In the experiment of researching the nanometer laser interferometer, our design of laser interferometer circuit system is up to the wireless communication technique of the 802.15.4 IEEE standard, and we use the RF TI provided by Basic to receive the data on speed control system software. The system's hardware is connected with control module and the DC motor. However, in the experiment, we found that single chip microcomputer control module is very difficult to drive the DC motor directly. The reason is that the DC motor's starting and braking current is larger than the causing current of the single chip microcomputer control module. In order to solve this problem, we add a driving module that control board can transmit PWM wave signal through I/O port to drive the DC motor, the driving circuit board can come true the function of the DC motor's positive and reversal rotation and speed adjustment. In many various driving module, the L298N module's integrated level is higher compared with other driver module. The L298N model is easy to control, it not only can control the DC motor, but also achieve motor speed control by modulating PWM wave that the control panel output. It also has the over-current protection function, when the motor lock, the L298N model can protect circuit and motor. So we use the driver module based on L298N to drive the DC motor. It is concluded that the L298N driver circuit module plays a very important role in the process of driving the DC motor in the DC motor speed control system.

  2. Precise control of the drug kinetics by means of non-invasive magnetic drug delivery system

    International Nuclear Information System (INIS)

    Chuzawa, M.; Mishima, F.; Akiyama, Y.; Nishijima, S.

    2013-01-01

    Highlights: ► We examined the kinetics of ferromagnetic drugs by simulation. ► We tried to accumulate the magnetic drug in the target part by rotating a magnet. ► Ferromagnetic drugs were accumulated in the target part along the rotating axis. ► Ferromagnetic drugs could be swept downstream in the off-axis part. -- Abstract: In order to solve the problems of the side effects and medical lowering, has been advanced a study on the drug delivery system (DDS) to accumulate the drugs locally in the body with minimum dosage. The DDS is a system that controls the drug kinetics in the body precisely and accumulates the drug locally at the target part, keeping the drugs at high density. Among the DDS, the magnetic drug delivery system (MDDS) is the one that we studied. This is a technique to accumulate drugs by using the magnetic force as the physical driving force. Our previous researches showed the possibility of the technique of MDDS to accumulate the drugs with higher accumulation rate and locality than the traditional methods. It is necessary to apply a strong external magnetic field and a high magnetic gradient to accumulate the ferromagnetic drugs at a deep diseased part non-invasively. However, by applying a static magnetic field from one direction, the drug accumulates only at the surface of the body locates near the magnet. In this study, we tried to change the magnetic field applied by a superconducting bulk magnet with time, in order to make a constant and strong magnetic field applied in the center of the body and to accumulate the ferromagnetic drugs at the deep target part in the body. First of all, the effect of the surface treatment of the ferromagnetic drugs to prevent its absorption in the normal tissue was examined. Then, to increase the accumulation rate of the ferromagnetic drugs at the target part, the distribution of magnetic field was changed, and the optimum spatial and temporal conditions of magnetic field were examined

  3. Controlling of processes for producing energy carriers by means of biotechnique. Reglering av processer foer att producera energibaerare med bioteknik

    Energy Technology Data Exchange (ETDEWEB)

    Mandenius, C F

    1987-01-01

    The most suitable parameter to reducing production cost is controlling of sugar content when converting sulfite lye or cellulose hydrolysate to ethanol. By keeping the sugar content low in the end product the yield and productivity are improved. A sensor for ethanol in the yeast tank has been developed and the continous analysis of glucose has been performed by means of an analyser for enzymes.

  4. A DC Microgrid Coordinated Control Strategy Based on Integrator Current-Sharing

    Directory of Open Access Journals (Sweden)

    Liyuan Gao

    2017-08-01

    Full Text Available The DC microgrid has become a new trend for microgrid study with the advantages of high reliability, simple control and low losses. With regard to the drawbacks of the traditional droop control strategies, an improved DC droop control strategy based on integrator current-sharing is introduced. In the strategy, the principle of eliminating deviation through an integrator is used, constructing the current-sharing term in order to make the power-sharing between different distributed generation (DG units uniform and reasonable, which can reduce the circulating current between DG units. Furthermore, at the system coordinated control level, a hierarchical/droop control strategy based on the DC bus voltage is proposed. In the strategy, the operation modes of the AC main network and micro-sources are determined through detecting the DC voltage variation, which can ensure the power balance of the DC microgrid under different operating conditions. Meanwhile, communication is not needed between different DG units, while each DG unit needs to sample the DC bus voltage, which retains the plug-and-play feature of the DC microgrid. The proposed control strategy is validated by simulation on a DC microgrid with permanent magnet synchronous generator-based wind turbines, solar arrays and energy storage batteries, which can be applied to small commercial or residential buildings.

  5. Power Management Based Current Control Technique for Photovoltaic-Battery Assisted Wind-Hydro Hybrid System

    Science.gov (United States)

    Ram Prabhakar, J.; Ragavan, K.

    2013-07-01

    This article proposes new power management based current control strategy for integrated wind-solar-hydro system equipped with battery storage mechanism. In this control technique, an indirect estimation of load current is done, through energy balance model, DC-link voltage control and droop control. This system features simpler energy management strategy and necessitates few power electronic converters, thereby minimizing the cost of the system. The generation-demand (G-D) management diagram is formulated based on the stochastic weather conditions and demand, which would likely moderate the gap between both. The features of management strategy deploying energy balance model include (1) regulating DC-link voltage within specified tolerances, (2) isolated operation without relying on external electric power transmission network, (3) indirect current control of hydro turbine driven induction generator and (4) seamless transition between grid-connected and off-grid operation modes. Furthermore, structuring of the hybrid system with appropriate selection of control variables enables power sharing among each energy conversion systems and battery storage mechanism. By addressing these intricacies, it is viable to regulate the frequency and voltage of the remote network at load end. The performance of the proposed composite scheme is demonstrated through time-domain simulation in MATLAB/Simulink environment.

  6. Control of trachoma in Australia: a model based evaluation of current interventions.

    Directory of Open Access Journals (Sweden)

    Andrew J Shattock

    2015-04-01

    Full Text Available Australia is the only high-income country in which endemic trachoma persists. In response, the Australian Government has recently invested heavily towards the nationwide control of the disease.A novel simulation model was developed to reflect the trachoma epidemic in Australian Aboriginal communities. The model, which incorporates demographic, migration, mixing, and biological heterogeneities, was used to evaluate recent intervention measures against counterfactual past scenarios, and also to assess the potential impact of a series of hypothesized future intervention measures relative to the current national strategy and intensity. The model simulations indicate that, under the current intervention strategy and intensity, the likelihood of controlling trachoma to less than 5% prevalence among 5-9 year-old children in hyperendemic communities by 2020 is 31% (19%-43%. By shifting intervention priorities such that large increases in the facial cleanliness of children are observed, this likelihood of controlling trachoma in hyperendemic communities is increased to 64% (53%-76%. The most effective intervention strategy incorporated large-scale antibiotic distribution programs whilst attaining ambitious yet feasible screening, treatment, facial cleanliness and housing construction targets. Accordingly, the estimated likelihood of controlling trachoma in these communities is increased to 86% (76%-95%.Maintaining the current intervention strategy and intensity is unlikely to be sufficient to control trachoma across Australia by 2020. However, by shifting the intervention strategy and increasing intensity, the likelihood of controlling trachoma nationwide can be significantly increased.

  7. Control of trachoma in Australia: a model based evaluation of current interventions.

    Science.gov (United States)

    Shattock, Andrew J; Gambhir, Manoj; Taylor, Hugh R; Cowling, Carleigh S; Kaldor, John M; Wilson, David P

    2015-04-01

    Australia is the only high-income country in which endemic trachoma persists. In response, the Australian Government has recently invested heavily towards the nationwide control of the disease. A novel simulation model was developed to reflect the trachoma epidemic in Australian Aboriginal communities. The model, which incorporates demographic, migration, mixing, and biological heterogeneities, was used to evaluate recent intervention measures against counterfactual past scenarios, and also to assess the potential impact of a series of hypothesized future intervention measures relative to the current national strategy and intensity. The model simulations indicate that, under the current intervention strategy and intensity, the likelihood of controlling trachoma to less than 5% prevalence among 5-9 year-old children in hyperendemic communities by 2020 is 31% (19%-43%). By shifting intervention priorities such that large increases in the facial cleanliness of children are observed, this likelihood of controlling trachoma in hyperendemic communities is increased to 64% (53%-76%). The most effective intervention strategy incorporated large-scale antibiotic distribution programs whilst attaining ambitious yet feasible screening, treatment, facial cleanliness and housing construction targets. Accordingly, the estimated likelihood of controlling trachoma in these communities is increased to 86% (76%-95%). Maintaining the current intervention strategy and intensity is unlikely to be sufficient to control trachoma across Australia by 2020. However, by shifting the intervention strategy and increasing intensity, the likelihood of controlling trachoma nationwide can be significantly increased.

  8. Parameter Improved Particle Swarm Optimization Based Direct-Current Vector Control Strategy for Solar PV System

    Directory of Open Access Journals (Sweden)

    NAMMALVAR, P.

    2018-02-01

    Full Text Available This paper projects Parameter Improved Particle Swarm Optimization (PIPSO based direct current vector control technology for the integration of photovoltaic array in an AC micro-grid to enhance the system performance and stability. A photovoltaic system incorporated with AC micro-grid is taken as the pursuit of research study. The test system features two power converters namely, PV side converter which consists of DC-DC boost converter with Perturbation and Observe (P&O MPPT control to reap most extreme power from the PV array, and grid side converter which consists of Grid Side-Voltage Source Converter (GS-VSC with proposed direct current vector control strategy. The gain of the proposed controller is chosen from a set of three values obtained using apriori test and tuned through the PIPSO algorithm so that the Integral of Time multiplied Absolute Error (ITAE between the actual and the desired DC link capacitor voltage reaches a minimum and allows the system to extract maximum power from PV system, whereas the existing d-q control strategy is found to perform slowly to control the DC link voltage under varying solar insolation and load fluctuations. From simulation results, it is evident that the proposed optimal control technique provides robust control and improved efficiency.

  9. Application of air traffic control competence reference models as a mean of air navigation services provider’s charge optimization

    Directory of Open Access Journals (Sweden)

    В.П. Харченко

    2010-01-01

    Full Text Available  The issue of application of Air Traffic Control (ATC competence reference models as a mean of air navigation services provider’s charge optimization is described in the article, and this issue is interpretated as an optimization task. The data relating to the significant growth of aviation traffic, especially using the airspace of Ukraine, given by authors, and the statement of fact that Air Traffic Management (ATM system’s technical component reliability increasement takes place on the basis of practically invariable psychophysiological abilities of aviation controller, make the substantiation of ANSP provision with the most trained ATC controllers for the work on the working places of ATC Unit actual. The ‘mechanism’ of ATC controllers competence reference model creation is defined step-by step. There is an example of candidate’s for the working place competence quantitative individual model forming as a common criteria of competence, which, in its turn, is the compressed format of all parameters of its working activity, received at the stage of control. The approach, according to which the individual parameters of graduating student’s output model’s professional characteristics, which he received after the examination of his work as Tower controller (ATM Unit of aerodrome control service, approach controller or area control service controller, are compared with the predetermined specialist’s competence reference model, relating to the special working place in ATM system, is supposed here. Notably, the conception, relating to the correspondence of the graduating student’s competence output level to the defined reference model of ATC controller, relating to the special working place of ATM Unit, is realised.

  10. Optimum Peak Current Hysteresis Control for Energy Recovering Converter in CDI Desalination

    Directory of Open Access Journals (Sweden)

    Alberto M. Pernía

    2014-06-01

    Full Text Available Capacitive De-Ionization (CDI is becoming a suitable alternative for desalination. The low cost of the materials required and its reduced energy consumption can be critical factors for developing this technique. CDI technology does not require a high-pressure system and the energy storage capability of CDI cells allows it to be reused in other CDI cells, thus minimizing consumption. The goal of the power stage responsible of the energy recovery is transferring the stored energy from one cell to another with the maximum possible efficiency, thus allowing the desalination process to continue. Assuming hysteresis current control is implemented at the DC/DC (direct current converter, this paper aims to determine the optimum peak current through the inductor in each switching period with a view to maximizing overall efficiency. The geometrical parameters of the desalination cell and the NaCl concentration modify the cell electrical properties. The peak current control of the power stage should be adapted to the cell characteristics so that the efficiency behavior of the whole CDI system can be improved. The mathematical model defined in this paper allows the CDI plant automation using the peak inductor current as control variable, adapting its value to the salt concentration during the desalination process.

  11. Model Predictive Current Control for High-Power Grid-Connected Converters with Output LCL Filter

    DEFF Research Database (Denmark)

    Delpino, Hernan Anres Miranda; Teodorescu, Remus; Rodriguez, Pedro

    2009-01-01

    A model predictive control strategy for a highpower, grid connected 3-level neutral clamped point converter is presented. Power losses constraints set a limit on commutation losses so reduced switching frequency is required, thus producing low frequency current harmonics. To reduce these harmonics...

  12. Compensation methods applied in current control schemes for large AC drive systems

    DEFF Research Database (Denmark)

    Rus, D. C.; Preda, N. S.; Teodorescu, Remus

    2012-01-01

    The paper deals with modified PI current control structures for large AC drive systems which use surface mounted permanent magnet synchronous machines or squirrel-cage induction motors supplied with voltage source inverters. In order to reduce the power losses caused by high frequency switching...

  13. Dynamic behavior of HTSC opening switch models controlled by short over-critical current pulses

    International Nuclear Information System (INIS)

    Agafonov, A.V.; Krastelev, E.G.; Voronin, V.S.

    1999-01-01

    We present results of experimental research of dynamical properties of thin films of YBa 2 Cu 3 O 7 HTSC-switch models under action of short overcritical current pulses to test this method of control of fast high-power opening switches for accelerator applications

  14. Sound Control in the Physic Lab in the Polyacryl Company and Studying the Noise Reduction by Means of Different Absorbents

    Directory of Open Access Journals (Sweden)

    Harandi

    1999-03-01

    Full Text Available Studying noise effect at the workplace has more various aspects than other factors. So it is not surprising that its adverse impact on the physical and mental state of the society has been detected to some extent. There is a significant correlation between the hearing loss and the noise pollution of the workplaces. The most important ways to lessen and control the impact of noise are: substituting the noisy equipments with ones that produce less noise, correcting noise sources and isolating the sound source. In the current study we tried to control the noise level by using various sound absorbents and measured sound level by using these different substances. The results of these measurements have reported in the current article in details.

  15. Assessment of current practices in creating and using passwords as a control mechanism for information access

    Directory of Open Access Journals (Sweden)

    P. L. Wessels

    2007-11-01

    Full Text Available One of the critical issues in managing information within an organization is to ensure that proper controls exist and are applied in allowing people access to information. Passwords are used extensively as the main control mechanism to identify users wanting access to systems, applications, data files, network servers or personal information. In this article, the issues involved in selecting and using passwords are discussed and the current practices employed by users in creating and storing passwords to gain access to sensitive information are assessed. The results of this survey conclude that information managers cannot rely only on users to employ proper password control in order to protect sensitive information.

  16. Filtering and Control of High Speed Motor Current in a Flywheel Energy Storage System

    Science.gov (United States)

    Kenny, Barbara H.; Santiago, Walter

    2004-01-01

    The NASA Glenn Research Center has been developing technology to enable the use of high speed flywheel energy storage units in future spacecraft for the last several years. An integral part of the flywheel unit is the three phase motor/generator that is used to accelerate and decelerate the flywheel. The motor/generator voltage is supplied from a pulse width modulated (PWM) inverter operating from a fixed DC voltage supply. The motor current is regulated through a closed loop current control that commands the necessary voltage from the inverter to achieve the desired current. The current regulation loop is the innermost control loop of the overall flywheel system and, as a result, must be fast and accurate over the entire operating speed range (20,000 to 60,000 rpm) of the flywheel. The voltage applied to the motor is a high frequency PWM version of the DC bus voltage that results in the commanded fundamental value plus higher order harmonics. Most of the harmonic content is at the switching frequency and above. The higher order harmonics cause a rapid change in voltage to be applied to the motor that can result in large voltage stresses across the motor windings. In addition, the high frequency content in the motor causes sensor noise in the magnetic bearings that leads to disturbances for the bearing control. To alleviate these problems, a filter is used to present a more sinusoidal voltage to the motor/generator. However, the filter adds additional dynamics and phase lag to the motor system that can interfere with the performance of the current regulator. This paper will discuss the tuning methodology and results for the motor/generator current regulator and the impact of the filter on the control. Results at speeds up to 50,000 rpm are presented.

  17. Method for exciting inductive-resistive loads with high and controllable direct current

    International Nuclear Information System (INIS)

    Hill, H.M. Jr.

    1976-01-01

    The apparatus and method for transmitting dc power to a load circuit by applying a dc voltage from a standard waveform synthesizer to duration modulate a bipolar rectangular wave generator are described. As the amplitude of the dc voltage increases, the widths of the rectangular wave generator output pulses increase, and as the amplitude of the dc voltage decreases, the widths of the rectangular wave generator output pulses decrease. Thus, the waveform synthesizer selectively changes the durations of the rectangular wave generator bipolar output pulses so as to produce a rectangular wave ac carrier that is duration modulated in accordance with and in direct proportion to the voltage amplitude from the synthesizer. Thereupon, by transferring the carrier to the load circuit through an amplifier and a rectifier, the load current also corresponds directly to the voltage amplitude from the synthesizer. To this end, the rectified wave at less than 100 percent duty factor amounts to a doubled frequency direct voltage pulse train for applying a direct current to the load, while the current ripple is minimized by a high L/R in the load circuit. In one embodiment, a power transmitting power amplifier means having a dc power supply is matched to the load circuit through a transformer for current magnification without sacrificing load current duration capability, while negative voltage and current feedback are provided in order to insure good output fidelity. 4 Claims, 18 Drawing Figures

  18. Direct-current vector control of three-phase grid-connected rectifier-inverter

    Energy Technology Data Exchange (ETDEWEB)

    Li, Shuhui; Haskew, Timothy A.; Hong, Yang-Ki; Xu, Ling [Department of Electrical and Computer Engineering, University of Alabama, Tuscaloosa, AL 35475 (United States)

    2011-02-15

    The three-phase grid-connected converter is widely used in renewable and electric power system applications. Traditionally, control of the three-phase grid-connected converter is based on the standard decoupled d-q vector control mechanism. Nevertheless, the study of this paper shows that there is a limitation in the conventional standard vector control method. Some of the limitations have also been found recently by other researchers. To overcome the shortage of the conventional vector control technique, this paper proposes a new direct-current d-q vector control mechanism in a nested-loop control structure, based on which an optimal control strategy is developed in a nonlinear programming formulation. The behaviors of both the conventional and proposed control methods are compared and evaluated in simulation and laboratory hardware experiment environments, both of which demonstrates that the proposed approach is effective for grid-connected power converter control in a wide system conditions while the conventional standard vector control approach may behave improperly especially when the converter operates beyond its PWM saturation limit. (author)

  19. LHCD current profile control experiments towards steady state improved confinement on JT-60U

    International Nuclear Information System (INIS)

    Ide, S.; Naito, O.; Oikawa, T.; Fujita, T.; Kondoh, T.; Seki, M.; Ushigusa, K.

    2001-01-01

    In JT-60U lower hybrid current drive (LHCD) experiments, a reversed magnetic shear configuration that was accompanied by the internal transport barriers was successfully maintained by means of LHCD almost in the full current drive quasi-steady state for 4.7 s. The normalized beta was kept near 1 and the neutron emission rate was almost steady as well indicating no accumulation of impurities into the plasma. Diagnostics data showed that all the profiles of the electron and ion temperatures, the electron density and the current profile were almost unchanged during the LHCD phase. Moreover, capability of LHCD in H-mode plasmas has been also investigated. It was found that the lower hybrid waves can be coupled to an H-mode edge plasma even with the plasma wall distance of about 14 cm. The maximum coupling distance was found to depend on the edge recycling. (author)

  20. Supervisory control and data acquisition system development for superconducting current feeder system of SST-1

    International Nuclear Information System (INIS)

    Patel, R.; Mahesuria, G.; Gupta, N.C.; Sonara, D.; Panchal, R.; Panchal, P.; Tanna, V.L.; Pradhan, S.

    2014-01-01

    The Current Feeders System (CFS) is essentially an optimized bridge between the power supply at room temperature and Super Conducting Magnet System (SCMS) of the SST-1 machine at 4.5 K.CFS is a complex electrical and cryogenic network which consists of ten pairs of 10 KA rating helium Vapor cooled Conventional Current Leads (VCCLs), superconducting (SC) current feeder and associated components. For the safe and reliable operation of CFS, it is equipped with different physical process parameters measuring instruments like flow, pressure, temperature, level, vacuum, voltage taps and final control element like control valves, heaters, vacuum pumps etc. PLC program is developed in ladder language for acquiring and controlling the process parameters. Independent SCADA applications developed in WonderwareIntouch software for data communication from PLC, front-end Graphical User Interface (GUI), auto-manual interface, real time trends, history trends, events and alarm pages. Time synchronized communication established between CFS control system and Industrial SQL server (InSQL) Historian for centralized storage of CFS process parameters which intern provides the CFS process data to SST-1 central control room. SCADA based data acquisition and data retrieval system is found to be satisfactory during the recent SST-1 cool down experiment. This paper describes the SCADA and PLC application development and their communication to InSQL server. (author)

  1. A circuit scheme to control current surge for RFID-NVM pumps

    International Nuclear Information System (INIS)

    Li Ming; Kang Jinfeng; Wang Yangyuan; Yang Liwu

    2010-01-01

    This paper presents a new circuit scheme to control the current surge in the boosting phase of an radio frequency idenfication-nonvolative memory pump. By introducing a circuit block consisting of a current reference and a current mirror, the new circuit scheme can keep the period-average current of the pump constantly below the desired level, for example, 2.5 μA. Therefore, it can prevent the rectified supply of the RFID tag IC from collapsing in the boosting phase of the pump. The presented scheme could effectively reduce the voltage drop on the rectified supply from more than 50% to even zero, but could cost less area. Moreover, an analytical expression to calculate the boosting time of a pump in the new scheme is developed. (semiconductor integrated circuits)

  2. A circuit scheme to control current surge for RFID-NVM pumps

    Energy Technology Data Exchange (ETDEWEB)

    Li Ming; Kang Jinfeng; Wang Yangyuan [Institute of Microelectronics, Peking University, Beijing 100871 (China); Yang Liwu, E-mail: prettynecess@163.co [Semiconductor Manufacturing International Corporation, Shanghai 201203 (China)

    2010-02-15

    This paper presents a new circuit scheme to control the current surge in the boosting phase of an radio frequency idenfication-nonvolative memory pump. By introducing a circuit block consisting of a current reference and a current mirror, the new circuit scheme can keep the period-average current of the pump constantly below the desired level, for example, 2.5 {mu}A. Therefore, it can prevent the rectified supply of the RFID tag IC from collapsing in the boosting phase of the pump. The presented scheme could effectively reduce the voltage drop on the rectified supply from more than 50% to even zero, but could cost less area. Moreover, an analytical expression to calculate the boosting time of a pump in the new scheme is developed. (semiconductor integrated circuits)

  3. Ultrafast terahertz control of extreme tunnel currents through single atoms on a silicon surface

    DEFF Research Database (Denmark)

    Jelic, Vedran; Iwaszczuk, Krzysztof; Nguyen, Peter H.

    2017-01-01

    scanning tunnelling microscopy (THz-STM) in ultrahigh vacuum as a new platform for exploring ultrafast non-equilibrium tunnelling dynamics with atomic precision. Extreme terahertz-pulse-driven tunnel currents up to 10(7) times larger than steady-state currents in conventional STM are used to image...... terahertz-induced band bending and non-equilibrium charging of surface states opens new conduction pathways to the bulk, enabling extreme transient tunnel currents to flow between the tip and sample.......Ultrafast control of current on the atomic scale is essential for future innovations in nanoelectronics. Extremely localized transient electric fields on the nanoscale can be achieved by coupling picosecond duration terahertz pulses to metallic nanostructures. Here, we demonstrate terahertz...

  4. Automated WWER steam generator eddy current testing and plugging control system

    International Nuclear Information System (INIS)

    Gorecan, I.; Gortan, K.; Grzalja, I.

    2004-01-01

    The structural architecture of the system contains three main components which are described as follows: Manipulator Guidance System; Eddy Current Testing System; Plugging System. The manipulator system has the task to position the end-effectors to the desired tube position. When the final position is reached, the Eddy Current testing system performs data acquisition. In case defects are found, the plugging system performs tube plug installment. Each system is composed of 3 layers. The first layer is the hardware layer consisting of motors driving the effectors along with sensors needed to obtain the positioning data, pusher motors used to push the test probes into tubes of the WWER steam generator, and plugging hardware tool. The second layer is the control box performing basic monitoring and control routines as an interconnection between first and third layer. The highest layer is the control software, running on the PC, which is used as a human-machine-interface.(author)

  5. Active control system upgrade design for lower hybrid current drive system on Alcator C-Mod

    Energy Technology Data Exchange (ETDEWEB)

    Kanojia, A.D., E-mail: akanojia@mit.edu [Massachusetts Institute of Technology Plasma Science and Fusion Center, Cambridge, MA (United States); Wallace, G.M.; Terry, D.R.; Stillerman, J.A.; Burke, W.M.; MacGibbon, P.A.; Johnson, D.K. [Massachusetts Institute of Technology Plasma Science and Fusion Center, Cambridge, MA (United States)

    2012-12-15

    Highlights: Black-Right-Pointing-Pointer Initial tests of the Hittite microwave components show good or better control of phase and amplitude when compared to the vector modulators used in the current system. Black-Right-Pointing-Pointer With an analog based control component system the system complexity is dramatically reduced. Black-Right-Pointing-Pointer Historically, D-tAcq hardware/software has performed more reliably on DPCS and FFT controllers than the current lower hybrid control system Black-Right-Pointing-Pointer Cost and lead time of the Hittite microwave components is significantly small compared to vector modulators. - Abstract: As a part of the scheduled expansion of the Alcator C-Mod lower hybrid current drive (LHCD) system from 12 to 16 klystrons to accommodate installation of a second LH antenna, the active control system (ACS) is being redesigned to accommodate the additional klystrons. Digitizers and output modules will be cPCI modules provided by D-tAcq Solutions. The real-time application will run on a standard PC server running Linux. Initially, the new ACS system will be designed to control 8 klystrons on the second LH antenna and the existing ACS will control the remaining 8 klystrons on the existing LH antenna. Experience gained operating the existing LHCD system has given us insight into the design of a more robust, compact, efficient and simple system for the new ACS. The design upgrade will be patterned on the digital plasma control system (DPCS [1]) in use on C-Mod.

  6. Decentralised control method for DC microgrids with improved current sharing accuracy

    DEFF Research Database (Denmark)

    Yang, Jie; Jin, Xinmin; Wu, Xuezhi

    2017-01-01

    A decentralised control method that deals with current sharing issues in dc microgrids (MGs) is proposed in this study. The proposed method is formulated in terms of ‘modified global indicator’ concept, which was originally proposed to improve reactive power sharing in ac MGs. In this work......, the ‘modified global indicator’ concept is extended to coordinate dc MGs, which aims to preserve the main features offered by decentralised control methods such as no need of communication links, central controller or knowledge of the microgrid topology and parameters. This global indicator is inserted between...... a shunt virtual resistance. The operation under multiple dc-buses is also included in order to enhance the applicability of the proposed controller. A detailed mathematical model including the effect of network mismatches is derived for analysis of the stability of the proposed controller. The feasibility...

  7. Flexible Microgrid Power Quality Enhancement Using Adaptive Hybrid Voltage and Current Controller

    DEFF Research Database (Denmark)

    He, Jinwei; Li, Yun Wei; Blaabjerg, Frede

    2014-01-01

    -pass/bandpass filters in the DG unit digital controller. Moreover, phase-locked loops are not necessary as the microgrid frequency deviation can be automatically identified by the power control loop. Consequently, the proposed control method provides opportunities to reduce DG control complexity, without affecting......To accomplish superior harmonic compensation performance using distributed generation (DG) unit power electronics interfaces, an adaptive hybrid voltage and current controlled method (HCM) is proposed in this paper. It shows that the proposed adaptive HCM can reduce the numbers of low...... the harmonic compensation performance. Comprehensive simulated and experimental results from a single-phase microgrid are provided to verify the feasibility of the proposed adaptive HCM approach....

  8. Autonomous Control of Current and Voltage Controlled DG Interface Inverters for Reactive Power Sharing and Harmonics Compensation in Islanded Microgrids

    DEFF Research Database (Denmark)

    Mousazadeh, Seyyed Yousef; Jalilain, Alireza; Savaghebi, Mehdi

    2018-01-01

    In microgrids, Voltage Source Inverters (VSIs) interfacing Distributed Generation (DG) units can be operated in Voltage or Current Controlled Modes (VCM/CCM). In this paper, a coordinated control of CCM and VCM units for reactive power sharing and voltage harmonics compensation is proposed....... This decentralized control scheme is based on the local measurement of signals. In this way, the need for communication links is removed which results in a simpler and more reliable structure compared to the communication based control structures. To be more exact, the VCM units contribute to harmonics compensation....... Experimental and simulation studies show that the harmonics compensation is achieved by using only local measurements in presence of virtual admittance/impedance schemes of CCM/VCM units. Furthermore, it is demonstrated that the reactive power sharing among the CCM and VCM units is obtained based...

  9. Current control methods for grid-side three-phase PWM voltage-source inverter in distributed generation systems

    DEFF Research Database (Denmark)

    Lar, Ionut Andrei; Radulescu, Mircea; Ritchie, Ewen

    2012-01-01

    A comparison between two current control methods of grid side inverter, PI current control and Robust Forward control is made. PI control is implemented in d-q synchronous frame while Forward is implemented in abc stationary frames.The report contains both simulations and experimental test wich...

  10. New current control based MPPT technique for single stage grid connected PV systems

    International Nuclear Information System (INIS)

    Jain, Sachin; Agarwal, Vivek

    2007-01-01

    This paper presents a new maximum power point tracking algorithm based on current control for a single stage grid connected photovoltaic system. The main advantage of this algorithm comes from its ability to predict the approximate amplitude of the reference current waveform or power that can be derived from the PV array with the help of an intermediate variable β. A variable step size for the change in reference amplitude during initial tracking helps in fast tracking. It is observed that if the reference current amplitude is greater than the array capacity, the system gets unstable (i.e. moves into the positive slope region of the p-v characteristics of the array). The proposed algorithm prevents the PV system from entering the positive slope region of the p-v characteristics. It is also capable of restoring stability if the system goes unstable due to a sudden environmental change. The proposed algorithm has been tested on a new single stage grid connected PV configuration recently developed by the authors to feed sinusoidal current into the grid. The system is operated in a continuous conduction mode to realize advantages such as low device current stress, high efficiency and low EMI. A fast MPPT tracker with single stage inverter topology operating in CCM makes the overall system highly efficient. Specific cases of the system, operating in just discontinuous current mode and discontinuous current mode and their relative merits and demerits are also discussed

  11. The control of the upstream movement of fish with pulsated direct current

    Science.gov (United States)

    McLain, Alberton L.

    1957-01-01

    Alternating-current electromechanical devices installed in the mouths of streams have proved effective in stopping the spawning migrations of the parasitic sea lamprey (Petromyzon marinus) which has seriously damaged Great Lakes fisheries. In a few streams, excessive mortality has occurred to other fish at the alternating-current barriers. A direct-current unit was developed in an attempt to reduce this mortality. This direct-current “diversion device” consists of a row of suspended negative electrodes which begins at the end of a trap wing and extends across the river at a downstream angle of 45° and a series of pipes (positive electrodes) driven into the stream bank. A second array, consisting of horizontal pipes installed downstream and parallel to the suspended electrodes and connected to a series of rods driven into the bank near the positive electrodes, controls the electrical field and dissipates the collecting influence of the positive side of the circuit. The electrical field is established from the end of the trap wing to the opposite bank. Fish are diverted away from the negative electrodes and toward the bank near which the trap is located. The array is activiated by pulsated direct current of essentially square wave shape with pulses at a duty cycle of 0.66 and a repetition rate of 3 per second. Direct-current diversion devices were operated in conjunction with alternating-current barriers during 1956 in the Chocolay River, Marquette County, and the Silver River, Baraga County, Michigan.

  12. Assessment of Current Estimates of Global and Regional Mean Sea Level from the TOPEX/Poseidon, Jason-1, and OSTM 17-Year Record

    Science.gov (United States)

    Beckley, Brian D.; Ray, Richard D.; Lemoine, Frank G.; Zelensky, N. P.; Holmes, S. A.; Desal, Shailen D.; Brown, Shannon; Mitchum, G. T.; Jacob, Samuel; Luthcke, Scott B.

    2010-01-01

    The science value of satellite altimeter observations has grown dramatically over time as enabling models and technologies have increased the value of data acquired on both past and present missions. With the prospect of an observational time series extending into several decades from TOPEX/Poseidon through Jason-1 and the Ocean Surface Topography Mission (OSTM), and further in time with a future set of operational altimeters, researchers are pushing the bounds of current technology and modeling capability in order to monitor global sea level rate at an accuracy of a few tenths of a mm/yr. The measurement of mean sea-level change from satellite altimetry requires an extreme stability of the altimeter measurement system since the signal being measured is at the level of a few mm/yr. This means that the orbit and reference frame within which the altimeter measurements are situated, and the associated altimeter corrections, must be stable and accurate enough to permit a robust MSL estimate. Foremost, orbit quality and consistency are critical to satellite altimeter measurement accuracy. The orbit defines the altimeter reference frame, and orbit error directly affects the altimeter measurement. Orbit error remains a major component in the error budget of all past and present altimeter missions. For example, inconsistencies in the International Terrestrial Reference Frame (ITRF) used to produce the precision orbits at different times cause systematic inconsistencies to appear in the multimission time-frame between TOPEX and Jason-1, and can affect the intermission calibration of these data. In an effort to adhere to cross mission consistency, we have generated the full time series of orbits for TOPEX/Poseidon (TP), Jason-1, and OSTM based on recent improvements in the satellite force models, reference systems, and modeling strategies. The recent release of the entire revised Jason-1 Geophysical Data Records, and recalibration of the microwave radiometer correction also

  13. Control of the UV flux of a XeCl dielectric barrier discharge excilamp through its current variation

    Energy Technology Data Exchange (ETDEWEB)

    Piquet, H; Bhosle, S; Diez, R; Cousineau, M; Djibrillah, M; Le Thanh, D; Dagang, A N; Zissis, G

    2012-02-28

    The efficiency of the electrical power transfer to the gas mixture of a XeCl dielectric barrier discharge (DBD) exciplex lamp is analysed. An equivalent circuit model of the DBD is considered. It is shown that the excilamp power can be controlled by applying current to the lamp. This highly desired property is ensured by means of a specific power supply topology, whose concepts and design are discussed. The experimental prototype of a current-mode converter operating in the pulsed regime at pulse repetition rate of 50 kHz is presented and its capability to control the amount of energy transferred during each current pulse is demonstrated. The capability of this power supply to maintain specific operating conditions for the DBD lamp, with a very stable behaviour (even at a very low current, in the regime of a single discharge channel), is illustrated. The experimental results of a combined use of this converter and a XeCl excilamp are presented. The influence of the supply parameters on the 308-nm XeCl excilamp is analysed. The shape of the UV pulse of the lamp is experimentally shown to be similar to that of the current, which actually flows into the gas mixture. The UV radiation power is demonstrated to be tightly correlated to the current injected into the gas and controlled by the available degrees of freedom offered by the power supply. The measured UV output characteristics and performance of the system are discussed. Time resolved UV imaging of a XeCl DBD excilamp is used to analyse the mechanisms involved in the production of exciplexes at various power supply regimes. It is shown that a pulsed voltage source leads to formation of short high intensity UV peaks, while current pulses lead to formation of sustained discharge filaments. Based on the results of modelling of the above-mentioned operation conditions, the two power supply regimes are compared and analysed from the point of view of the UV power and radiative control.

  14. A Highly Robust Single-Loop Current Control Scheme for Grid-Connected Inverter with an Improved LCCL Filter Configuration

    DEFF Research Database (Denmark)

    Pan, Donghua; Ruan, Xinbo; Wang, Xiongfei

    2018-01-01

    Single-loop current control is an attractive scheme for the LCL-type grid-connected inverter due to its simplicity and low cost. However, conventional single-loop control schemes, which command either the inverter current or the grid current, are subject to the specific resonance frequency regions....... The weighted average current control, which splits the filter capacitor into two parts (in form of an LCCL filter) and commands the current flowing between these two parts, is independent of the resonance frequency, but on the other hand, it is limited by the poor sensitivity to the grid impedance variation...... and weak stability in the grid current. These limitations are comprehensively explained in this paper and then addressed by identifying that the single-loop weighted average current control is equivalent to the dual-loop grid current control with an inherent capacitor current active damping. By tuning...

  15. Plasma position and current control system enhancements for the JET ITER-like wall

    Energy Technology Data Exchange (ETDEWEB)

    De Tommasi, G. [Associazione EURATOM-ENEA-CREATE, Univ. di Napoli Federico II, Via Claudio 21, 80125 Napoli (Italy); Maviglia, F. [Associazione EURATOM-ENEA-CREATE, Via Claudio 21, 80125 Napoli (Italy); Neto, A.C. [Ass. EURATOM-IST, Instituto de Plasmas e Fusão Nuclear, IST, 1049-001 Lisboa (Portugal); Lomas, P.J.; McCullen, P.; Rimini, F.G. [Euratom-CCFE, Culham Science Centre, OX14 3DB Abingdon (United Kingdom)

    2014-03-15

    Highlights: • JET plasma position and current control system enhanced for the JET ITER like wall. • Vertical stabilization system enhanced to speed up its response and to withstand larger perturbations. • Improved termination management system. • Implementation of the current limit avoidance system. • Implementation of PFX-on-early-task. - Abstract: The upgrade of Joint European Torus (JET) to a new all-metal wall, the so-called ITER-like wall (ILW), has posed a set of new challenges regarding both machine operation and protection. The plasma position and current control (PPCC) system plays a crucial role in minimizing the possibility that the plasma could permanently damage the ILW. The installation of the ILW has driven a number of upgrades of the two PPCC components, namely the Vertical Stabilization (VS) system and the Shape Controller (SC). The VS system has been enhanced in order to speed up its response and to withstand larger perturbations. The SC upgrade includes three new features: an improved termination management system, the current limit avoidance system, and the PFX-on-early-task. This paper describes the PPCC upgrades listed above, focusing on the implementation issues and on the experimental results achieved during the 2011–12 JET experimental campaigns.

  16. A Digital Hysteresis Current Control for Half-Bridge Inverters with Constrained Switching Frequency

    Directory of Open Access Journals (Sweden)

    Triet Nguyen-Van

    2017-10-01

    Full Text Available This paper proposes a new robustly adaptive hysteresis current digital control algorithm for half-bridge inverters, which plays an important role in electric power, and in various applications in electronic systems. The proposed control algorithm is assumed to be implemented on a high-speed Field Programmable Gate Array (FPGA circuit, using measured data with high sampling frequency. The hysteresis current band is computed in each switching modulation period based on both the current error and the negative half switching period during the previous modulation period, in addition to the conventionally used voltages measured at computation instants. The proposed control algorithm is derived by solving the optimization problem—where the switching frequency is always constrained at below the desired constant frequency—which is not guaranteed by the conventional method. The optimization problem also keeps the output current stable around the reference, and minimizes power loss. Simulation results show good performances of the proposed algorithm compared with the conventional one.

  17. Comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters

    Energy Technology Data Exchange (ETDEWEB)

    Pettersson, S.

    2009-07-01

    During the past two decades, active power filters have increasingly grown their popularity as a viable method for improving electric power quality. The main reasons for this have been the advent of fast self-commutating solid-state devices, the progression of digital technology and the improved sensor technology. Four-wire active power filters provide an efficient solution for improving the quality of supply in grounded three-phase systems or three-phase systems with neutral conductors, which are commonly used for powering residential, office and public buildings. Four-wire active power filters are applicable in compensating current harmonics, reactive power, neutral current and load phase imbalance.This thesis presents a comparative study of microcontroller controlled four-wire voltage and current source shunt active power filters. The study includes two voltage source topologies and a current source topology with two different dc-link energy storage structures, which are compared on the basis of their filtering properties, filtering performance and efficiency. The obtained results are used for determining the suitability of current source technology for four-wire active power filtering and finding the most viable four-wire shunt active power filter topology. One commonly recognized disadvantage of the current source active power filter has always been the bulky dc-link inductor. To reduce the size of the dc-link inductor, an alternative dc-link structure for current source active power filters was introduced in the late 80's. The hybrid energy storage consists of both inductive and capacitive energy storage elements, two diodes and two controllable semiconductor switching devices. Since the capacitive element is used as a main storage unit, the inductance of the dc-link inductor can be considerably reduced. However, the original dc current control method proposed is not able to utilize the full potential of the hybrid energy storage and the inductance

  18. Variable speed wind turbine generator system with current controlled voltage source inverter

    International Nuclear Information System (INIS)

    Muyeen, S.M.; Al-Durra, Ahmed; Tamura, J.

    2011-01-01

    highlights: → Current controlled voltage source inverter scheme for wind power application. → Low voltage ride through of wind farm. → Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  19. Variable speed wind turbine generator system with current controlled voltage source inverter

    Energy Technology Data Exchange (ETDEWEB)

    Muyeen, S.M., E-mail: muyeen0809@yahoo.co [Dept. of Electrical Engineering, Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Al-Durra, Ahmed [Dept. of Electrical Engineering, The Petroleum Institute, P.O. Box 2533, Abu Dhabi (United Arab Emirates); Tamura, J. [Dept. of EEE, Kitami Institute of Technology, 165 Koen-cho, Kitami 090-8507 (Japan)

    2011-07-15

    highlights: {yields} Current controlled voltage source inverter scheme for wind power application. {yields} Low voltage ride through of wind farm. {yields} Variable speed wind turbine driven permanent magnet synchronous generator-operation and control. -- Abstract: The present popular trend of wind power generation is to use variable speed wind turbine (VSWT) driving a doubly fed induction generator (DFIG), wound field synchronous generator (WFSG) or permanent magnet synchronous generator (PMSG). Among them, stability analyses of DFIG type of VSWT have already been reported in many literatures. However, transient stability and low voltage ride through (LVRT) characteristics analyses for synchronous generator type of VSWT is not sufficient enough. This paper focuses on detailed LVRT characteristic analysis of variable speed wind turbine driving a PMSG (VSWT-PMSG) with current controlled voltage source inverter (CC-VSI). Modeling and suitable control strategies for overall system are developed to augment the low voltage ride through capability of variable speed wind generator, considering recent wind farm grid code. Both symmetrical and unsymmetrical faults are analyzed as network disturbances in this paper. The permanent fault due to unsuccessful reclosing of circuit breakers is taken into consideration, which is a salient feature of this study. Moreover, the dynamic characteristic is analyzed using real wind speed data measured in Hokkaido Island, Japan. The proposed control scheme is simulated by using the standard power system simulation package PSCAD/EMTDC and results are verified by comparing that of voltage controlled voltage source inverter scheme available in power system literature.

  20. Current status and prospect of plasma control system for steady-state operation on QUEST

    International Nuclear Information System (INIS)

    Hasegawa, Makoto; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2016-01-01

    Highlights: • Overall configuration of plasma control system on QUEST are presented. • Multi core system and reflective memories are used for the real-time control. • Hall sensors are used for the identification of plasma current and its position. • Repetitive gas fueling with the feed-back control of Hα signal is implemented. - Abstract: The plasma control system (PCS) of QUEST is developed according to the progress of QUEST project. Since one of the critical goals of the project is to achieve the steady-state operation with high temperature vacuum vessel wall, the PCS is also required to have the capability to control the plasma for a long period. For the increase of the loads to processing power of the PCS, the PCS is decentralized with the use of reflective memories (RFMs). The PCS controls the plasma edge position with the real-time identification of plasma current and its position. This identification is done with not only flux loops but also hall sensors. The gas fueling method by piezo valve with monitoring the Hα signal filtered by a digital low-pass filter are proposed and suitable for the steady-state operation on QUEST. The present status and prospect of the PCS are presented with recent topics.

  1. Current status and prospect of plasma control system for steady-state operation on QUEST

    Energy Technology Data Exchange (ETDEWEB)

    Hasegawa, Makoto, E-mail: hasegawa@triam.kyushu-u.ac.jp; Nakamura, Kazuo; Zushi, Hideki; Hanada, Kazuaki; Fujisawa, Akihide; Tokunaga, Kazutoshi; Idei, Hiroshi; Nagashima, Yoshihiko; Kawasaki, Shoji; Nakashima, Hisatoshi; Higashijima, Aki

    2016-11-15

    Highlights: • Overall configuration of plasma control system on QUEST are presented. • Multi core system and reflective memories are used for the real-time control. • Hall sensors are used for the identification of plasma current and its position. • Repetitive gas fueling with the feed-back control of Hα signal is implemented. - Abstract: The plasma control system (PCS) of QUEST is developed according to the progress of QUEST project. Since one of the critical goals of the project is to achieve the steady-state operation with high temperature vacuum vessel wall, the PCS is also required to have the capability to control the plasma for a long period. For the increase of the loads to processing power of the PCS, the PCS is decentralized with the use of reflective memories (RFMs). The PCS controls the plasma edge position with the real-time identification of plasma current and its position. This identification is done with not only flux loops but also hall sensors. The gas fueling method by piezo valve with monitoring the Hα signal filtered by a digital low-pass filter are proposed and suitable for the steady-state operation on QUEST. The present status and prospect of the PCS are presented with recent topics.

  2. A new approach to control a deflection of an electroplated microstructure: dual current electroplating methods

    International Nuclear Information System (INIS)

    Yang, Hyun-Ho; Seo, Min-Ho; Han, Chang-Hoon; Yoon, Jun-Bo

    2013-01-01

    We propose and demonstrate a simple and novel method to control the deflection in a suspended microstructure by using a dual current electroplating (DuCE) method. The key concept of this method is to divide the structure into two layers—a bottom layer and a top layer—and then apply respective current densities in electroplating to those two layers while all other conditions are kept the same. In addition to a flat structure, the direction of structure bending is freely controlled by virtue of the DuCE method. Cantilever Ni beams with a length of 400 µm, which were electroplated by the conventional single current electroplating method, bent downward with a deflection of 3.4 µm. On the contrary, by the DuCE method, cantilever beams with a length of 400 µm showed an almost flat structure as desired. (The current densities of the bottom layer, the top layer, and the ratio of the two current densities, are 0.15, 1.24 A dm −2 , and 8.3, respectively.) Consequently, a nickel electroplated spiral structure with a length of 8600 µm was suspended flat with an end deflection of less than 0.7 µm (the ratio between the deflection and length is 0.007%). This work therefore represents the unprecedented ultra-long suspended microstructure with submicrometer deflection. (paper)

  3. An improved empirical dynamic control system model of global mean sea level rise and surface temperature change

    Science.gov (United States)

    Wu, Qing; Luu, Quang-Hung; Tkalich, Pavel; Chen, Ge

    2018-04-01

    Having great impacts on human lives, global warming and associated sea level rise are believed to be strongly linked to anthropogenic causes. Statistical approach offers a simple and yet conceptually verifiable combination of remotely connected climate variables and indices, including sea level and surface temperature. We propose an improved statistical reconstruction model based on the empirical dynamic control system by taking into account the climate variability and deriving parameters from Monte Carlo cross-validation random experiments. For the historic data from 1880 to 2001, we yielded higher correlation results compared to those from other dynamic empirical models. The averaged root mean square errors are reduced in both reconstructed fields, namely, the global mean surface temperature (by 24-37%) and the global mean sea level (by 5-25%). Our model is also more robust as it notably diminished the unstable problem associated with varying initial values. Such results suggest that the model not only enhances significantly the global mean reconstructions of temperature and sea level but also may have a potential to improve future projections.

  4. Voltage-Controlled Square/Triangular Wave Generator with Current Conveyors and Switching Diodes

    Directory of Open Access Journals (Sweden)

    Martin Janecek

    2012-12-01

    Full Text Available A novel relaxation oscillator based on integrating the diode-switched currents and Schmitt trigger is presented. It is derived from a known circuit with operational amplifiers where these active elements were replaced by current conveyors. The circuit employs only grounded resistances and capacitance and is suitable for high frequency square and triangular signal generation. Its frequency can be linearly and accurately controlled by voltage that is applied to a high-impedance input. Computer simulation with a model of a manufactured conveyor prototype verifies theoretic assumptions.

  5. Effects of personal experiences on the interpretation of the meaning of colours used in the displays and controls in electric control panels.

    Science.gov (United States)

    Lee, Inseok; Hwang, Won-Gue

    2015-01-01

    A survey was conducted to examine how personal experiences affect the interpretation of the meaning of display and control colours on electric control panels (ECPs). In Korea, the red light on ECPs represents a normal state of operation, while the green light represents a stopped state of operation; this appears to contradict the general stereotypes surrounding these colours. The survey results indicated that the participants who had experience in using ECPs interpreted the colour meaning differently from the other participant group. More than half of the experienced participants regarded the coloured displays and controls as they were designed, while most participants in the other group appeared to interpret the colours in accordance with the stereotypes. It is presumed that accidents related to human errors can occur when non-experienced people use the ECPs, which are easily accessible in many buildings. Practitioner Summary: A survey was conducted to investigate how personal experiences affect the interpretation of the function meanings of coloured lights on electrical control panels. It was found that the interpretation varies according to personal experiences, which can induce accidents related to human errors while operating electrical equipment.

  6. [Current situation of human resources of parasitic disease control and prevention organizations in Henan Province].

    Science.gov (United States)

    Ya-Lan, Zhang; Yan-Kun, Zhu; Wei-Qi, Chen; Yan, Deng; Peng, Li

    2018-01-10

    To understand the current status of human resources of parasitic disease control and prevention organizations in Henan Province, so as to provide the reference for promoting the integrative ability of the prevention and control of parasitic diseases in Henan Province. The questionnaires were designed and the method of census was adopted. The information, such as the amounts, majors, education background, technical titles, working years, and turnover in each parasitic disease control and prevention organization was collected by the centers for disease control and prevention (CDCs) at all levels. The data were descriptively analyzed. Totally 179 CDCs were investigated, in which only 19.0% (34/179) had the independent parasitic diseases control institution (department) . There were only 258 full-time staffs working on parasitic disease control and prevention in the whole province, in which only 61.9% (159/258) were health professionals. Those with junior college degree or below in the health professionals accounted for 60.3% (96/159) . Most of them (42.1%) had over 20 years of experience, but 57.9% (92/159) of their technical post titles were at primary level or below. The proportion of the health professionals is low in the parasitic disease control and prevention organizations in Henan Province. The human resource construction for parasitic disease control and prevention at all levels should be strengthened.

  7. Transcranial direct current stimulation for depression in Alzheimer's disease: study protocol for a randomized controlled trial.

    Science.gov (United States)

    Narita, Zui; Yokoi, Yuma

    2017-06-19

    Patients with Alzheimer's disease frequently elicit neuropsychiatric symptoms as well as cognitive deficits. Above all, depression is one of the most common neuropsychiatric symptoms in Alzheimer's disease but antidepressant drugs have not shown significant beneficial effects on it. Moreover, electroconvulsive therapy has not ensured its safety for potential severe adverse events although it does show beneficial clinical effect. Transcranial direct current stimulation can be the safe alternative of neuromodulation, which applies weak direct electrical current to the brain. Although transcranial direct current stimulation has plausible evidence for its effect on depression in young adult patients, no study has explored it in older subjects with depression in Alzheimer's disease. Therefore, we present a study protocol designed to evaluate the safety and clinical effect of transcranial direct current stimulation on depression in Alzheimer's disease in subjects aged over 65 years. This is a two-arm, parallel-design, randomized controlled trial, in which patients and assessors will be blinded. Subjects will be randomized to either an active or a sham transcranial direct current stimulation group. Participants in both groups will be evaluated at baseline, immediately, and 2 weeks after the intervention. This study investigates the safety and effect of transcranial direct current stimulation that may bring a significant impact on both depression and cognition in patients with Alzheimer's disease, and may be useful to enhance their quality of life. ClinicalTrials.gov, NCT02351388 . Registered on 27 January 2015. Last updated on 30 May 2016.

  8. A programmable controller for constant primary peak current in capacitor charging fet switcher for nova

    International Nuclear Information System (INIS)

    Mihalka, A.

    1983-01-01

    New switching power supplies were designed for the 10 mm laser amplifiers in the Nova master oscillator room. The flashlamp supply must be repeatable. Therefore, the authors designed a constant current, linearly charging power supply. Since it is a capacitor, the load varies through-out the charge cycle. At first the load is great, and DI/DT of load current is at a maximum. As the capacitor charges the initial conditions for each cycle change, the power supply in effect sees a smaller capacitance, and DI/DT decreases. We need a way of gradually increasing the on-time of the current pulses so that the transistors in the power bridge are turned off when they reach their maximum peak current. The normal current sense response of the control chip is not fast enough to be useful for the application. The deadtime, or the time that all the bridge transistors are turned off, is fixed so that as the pulse width varies so does the period. We end up with a constant peak current, switching power supply whose frequency varies from 50 khz to 20 khz. Finally, an overcurrent latch protects the transistors from bridge or transformer faults. the circuit is described and results are shown

  9. Neural network evaluation of tokamak current profiles for real time control (abstract)

    Science.gov (United States)

    Wróblewski, Dariusz

    1997-01-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q0, minimum value of q, qmin, and the location of qmin. Very good performance of the trained neural network both for simulated test data and for experimental data is demonstrated.

  10. Neural network evaluation of tokamak current profiles for real time control

    Science.gov (United States)

    Wróblewski, Dariusz

    1997-02-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q0, minimum value of q, qmin, and the location of qmin. Very good performance of the trained neural network both for simulated test data and for experimental datais demonstrated.

  11. Neural network evaluation of tokamak current profiles for real time control

    International Nuclear Information System (INIS)

    Wroblewski, D.

    1997-01-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q 0 , minimum value of q, q min , and the location of q min . Very good performance of the trained neural network both for simulated test data and for experimental datais demonstrated. copyright 1997 American Institute of Physics

  12. Neural network evaluation of tokamak current profiles for real time control (abstract)

    International Nuclear Information System (INIS)

    Wroblewski, D.

    1997-01-01

    Active feedback control of the current profile, requiring real-time determination of the current profile parameters, is envisioned for tokamaks operating in enhanced confinement regimes. The distribution of toroidal current in a tokamak is now routinely evaluated based on external (magnetic probes, flux loops) and internal (motional Stark effect) measurements of the poloidal magnetic field. However, the analysis involves reconstruction of magnetohydrodynamic equilibrium and is too intensive computationally to be performed in real time. In the present study, a neural network is used to provide a mapping from the magnetic measurements (internal and external) to selected parameters of the safety factor profile. The single-pass, feedforward calculation of output of a trained neural network is very fast, making this approach particularly suitable for real-time applications. The network was trained on a large set of simulated equilibrium data for the DIII-D tokamak. The database encompasses a large variety of current profiles including the hollow current profiles important for reversed central shear operation. The parameters of safety factor profile (a quantity related to the current profile through the magnetic field tilt angle) estimated by the neural network include central safety factor, q 0 , minimum value of q, q min , and the location of q min . Very good performance of the trained neural network both for simulated test data and for experimental data is demonstrated. copyright 1997 American Institute of Physics

  13. THE DUAL CONTROL – A REQUIREMENT OF THE CURRENT BANK MANAGEMENT

    Directory of Open Access Journals (Sweden)

    ALINA MATIȘ

    2014-10-01

    Full Text Available Security is a major problem of the banking industry, which bases its whole system on the reputation the bank manages to establish and then maintain among its customers. With the manifestation of information security issues and in interdependence with them, the need for internal control also developed, both of them being associated with modern risk management practices. As the concept of internal control has been rising as a major concern of management and corporate governance, there are attempts to classify it and distinguish it in different categories, dual control being a result of this process. The authors of this study attempt to present the concept of dual control as it is currently applied in the banking system, trying to analyze contextually its capacities of fraud detection, its consequences in terms of risk and costs as well as its effects on bank performance.

  14. Acceleration feedback of a current-following synchronized control algorithm for telescope elevation axis

    Science.gov (United States)

    Tang, Tao; Zhang, Tong; Du, Jun-Feng; Ren, Ge; Tian, Jing

    2016-11-01

    This paper proposes a dual-motor configuration to enhance closed-loop performance of a telescope control system. Two identical motors are mounted on each side of a U-type frame to drive the telescope elevation axis instead of a single motor drive, which is usually used in a classical design. This new configuration and mechanism can reduce the motor to half the size used in the former design, and it also provides some other advantages. A master-slave current control mode is employed to synchronize the two motors. Acceleration feedback control is utilized to further enhance the servo performance. Extensive experiments are used to validate the effectiveness of the proposed control algorithm in synchronization, disturbance attenuation and low-velocity tracking.

  15. Design of Programmable LED Controller with a Variable Current Source for 3D Image Display

    Directory of Open Access Journals (Sweden)

    Kyung-Ryang Lee

    2014-12-01

    Full Text Available Conventional fluorescent light sources, as well as incandescent light sources are gradually being replaced by Light Emitting Diodes (LEDs for reducing power consumption in the image display area for multimedia application. An LED light source requires a controller with a low-power operation. In this paper, a low-power technique using adiabatic operation is applied for the implementation of LED controller with a stable constant-current, a low-power and low-heat function. From the simulation result, the power consumption of the proposed LED controller using adiabatic operation was reduced to about 87% in comparison with conventional operation with a constant VDD. The proposed circuit is expected to be an alternative LED controller which is sensitive to external conditions such as heat.

  16. Postural Control Impairments in Individuals With Autism Spectrum Disorder: A Critical Review of Current Literature

    Science.gov (United States)

    Memari, Amir Hossein; Ghanouni, Parisa; Shayestehfar, Monir; Ghaheri, Banafsheh

    2014-01-01

    Context: Motor impairments in individuals with autism spectrum disorder (ASD) have been frequently reported. In this review, we narrow our focus on postural control impairments to summarize current literature for patterns, underlying mechanisms, and determinants of posture in this population. Evidence Acquisition: A literature search was conducted through Medline, ISI web of Knowledge, Scopus and Google Scholar to include studies between 1992 and February 2013. Results: Individuals with ASD have problems in maintaining postural control in infancy that well persists into later years. However, the patterns and underlying mechanisms are still unclear. Conclusions: Examining postural control as an endophenotype or early diagnostic marker of autism is a conceptual premise which should be considered in future investigations. At the end of the review, methodological recommendations on the assessment of postural control have also been provided. PMID:25520765

  17. Stochastic optimal control as non-equilibrium statistical mechanics: calculus of variations over density and current

    Science.gov (United States)

    Chernyak, Vladimir Y.; Chertkov, Michael; Bierkens, Joris; Kappen, Hilbert J.

    2014-01-01

    In stochastic optimal control (SOC) one minimizes the average cost-to-go, that consists of the cost-of-control (amount of efforts), cost-of-space (where one wants the system to be) and the target cost (where one wants the system to arrive), for a system participating in forced and controlled Langevin dynamics. We extend the SOC problem by introducing an additional cost-of-dynamics, characterized by a vector potential. We propose derivation of the generalized gauge-invariant Hamilton-Jacobi-Bellman equation as a variation over density and current, suggest hydrodynamic interpretation and discuss examples, e.g., ergodic control of a particle-within-a-circle, illustrating non-equilibrium space-time complexity.

  18. [Testing of the effect of classic conditioning stimuli in human experiment by means of the transfer of control paradigm].

    Science.gov (United States)

    Wolter, J

    1999-01-01

    Pavlovian conditioning in animals is often evaluated by means of transfer of control experiments. With human subjects, however, only very few studies have been conducted and the outcomes were often not in accordance with theoretical explanations based on studies with animals. A theoretical framework is presented that tries to integrate the results of the human conditioning paradigm and the animal conditioning paradigm as well, with reference to the well-known Yerkes-Dodson law. The experimental study with human subjects (N = 24) confirmed the predictions out of this framework, when a procedure similar to animal research is applied.

  19. Means-End based Functional Modeling for Intelligent Control: Modeling and Experiments with an Industrial Heat Pump System

    DEFF Research Database (Denmark)

    Saleem, Arshad

    2007-01-01

    The purpose of this paper is to present a Multilevel Flow Model (MFM) of an industrial heat pump system and its use for diagnostic reasoning. MFM is functional modeling language supporting an explicit means-ends intelligent control strategy for large industrial process plants. The model is used...... in several diagnostic experiments analyzing different fault scenarios. The model and results of the experiments are explained and it is shown how MFM based intelligent modeling and automated reasoning can improve the fault diagnosis process significantly....

  20. Hysteretic self-oscillating bandpass current mode control for Class D audio amplifiers driving capacitive transducers

    DEFF Research Database (Denmark)

    Nielsen, Dennis; Knott, Arnold; Andersen, Michael A. E.

    2013-01-01

    A hysteretic self-oscillating bandpass current mode control (BPCM) scheme for Class D audio amplifiers driving capacitive transducers are presented. The scheme provides excellent stability margins and low distortion over a wide range of operating conditions. Small-signal behavior of the amplifier...... the rules of electrostatics have been known as very interesting alternatives to the traditional inefficient electrodynamic transducers. When driving capacitive transducers from a Class D audio amplifier the high impedance nature of the load represents a key challenge. The BPCM control scheme ensures a flat...