WorldWideScience

Sample records for cumulative lead dose

  1. Lead in teeth from lead-dosed goats: Microdistribution and relationship to the cumulative lead dose

    International Nuclear Information System (INIS)

    Bellis, David J.; Hetter, Katherine M.; Jones, Joseph; Amarasiriwardena, Dula; Parsons, Patrick J.

    2008-01-01

    Teeth are commonly used as a biomarker of long-term lead exposure. There appear to be few data, however, on the content or distribution of lead in teeth where data on specific lead intake (dose) are also available. This study describes the analysis of a convenience sample of teeth from animals that were dosed with lead for other purposes, i.e., a proficiency testing program for blood lead. Lead concentration of whole teeth obtained from 23 animals, as determined by atomic absorption spectrometry, varied from 0.6 to 80 μg g -1 . Linear regression of whole tooth lead (μg g -1 ) on the cumulative lead dose received by the animal (g) yielded a slope of 1.2, with r 2 =0.647 (p -1 , were found in circumpulpal dentine. Linear regression of circumpulpal lead (μg g -1 ) on cumulative lead dose (g) yielded a slope of 23 with r 2 =0.961 (p=0.0001). The data indicated that whole tooth lead, and especially circumpulpal lead, of dosed goats increased linearly with cumulative lead exposure. These data suggest that circumpulpal dentine is a better biomarker of cumulative lead exposure than is whole tooth lead, at least for lead-dosed goats

  2. Dose-Response Relationship between Cumulative Occupational Lead Exposure and the Associated Health Damages: A 20-Year Cohort Study of a Smelter in China.

    Science.gov (United States)

    Wu, Yue; Gu, Jun-Ming; Huang, Yun; Duan, Yan-Ying; Huang, Rui-Xue; Hu, Jian-An

    2016-03-16

    Long-term airborne lead exposure, even below official occupational limits, has been found to cause lead poisoning at higher frequencies than expected, which suggests that China's existing occupational exposure limits should be reexamined. A retrospective cohort study was conducted on 1832 smelting workers from 1988 to 2008 in China. These were individuals who entered the plant and came into continuous contact with lead at work for longer than 3 months. The dose-response relationship between occupational cumulative lead exposure and lead poisoning, abnormal blood lead, urinary lead and erythrocyte zinc protoporphyrin (ZPP) were analyzed and the benchmark dose lower bound confidence limits (BMDLs) were calculated. Statistically significant positive correlations were found between cumulative lead dust and lead fumes exposures and workplace seniority, blood lead, urinary lead and ZPP values. A dose-response relationship was observed between cumulative lead dust or lead fumes exposure and lead poisoning (p lead dust and fumes doses were 0.68 mg-year/m³ and 0.30 mg-year/m³ for lead poisoning, respectively. The BMDLs of workplace airborne lead concentrations associated with lead poisoning were 0.02 mg/m³ and 0.01 mg/m³ for occupational exposure lead dust and lead fume, respectively. In conclusion, BMDLs for airborne lead were lower than occupational exposure limits, suggesting that the occupational lead exposure limits need re-examination and adjustment. Occupational cumulative exposure limits (OCELs) should be established to better prevent occupational lead poisoning.

  3. Dose-Response Relationship between Cumulative Occupational Lead Exposure and the Associated Health Damages: A 20-Year Cohort Study of a Smelter in China

    OpenAIRE

    Yue Wu; Jun-Ming Gu; Yun Huang; Yan-Ying Duan; Rui-Xue Huang; Jian-An Hu

    2016-01-01

    Long-term airborne lead exposure, even below official occupational limits, has been found to cause lead poisoning at higher frequencies than expected, which suggests that China’s existing occupational exposure limits should be reexamined. A retrospective cohort study was conducted on 1832 smelting workers from 1988 to 2008 in China. These were individuals who entered the plant and came into continuous contact with lead at work for longer than 3 months. The dose-response relationship between o...

  4. Cumulative radiation dose of multiple trauma patients during their hospitalization

    International Nuclear Information System (INIS)

    Wang Zhikang; Sun Jianzhong; Zhao Zudan

    2012-01-01

    Objective: To study the cumulative radiation dose of multiple trauma patients during their hospitalization and to analyze the dose influence factors. Methods: The DLP for CT and DR were retrospectively collected from the patients during June, 2009 and April, 2011 at a university affiliated hospital. The cumulative radiation doses were calculated by summing typical effective doses of the anatomic regions scanned. Results: The cumulative radiation doses of 113 patients were collected. The maximum,minimum and the mean values of cumulative effective doses were 153.3, 16.48 mSv and (52.3 ± 26.6) mSv. Conclusions: Multiple trauma patients have high cumulative radiation exposure. Therefore, the management of cumulative radiation doses should be enhanced. To establish the individualized radiation exposure archives will be helpful for the clinicians and technicians to make decision whether to image again and how to select the imaging parameters. (authors)

  5. In vivo x-ray fluorescence of bone lead in the study of human lead metabolism: Serum lead, whole blood lead, bone lead, and cumulative exposure

    International Nuclear Information System (INIS)

    Cake, K.M.; Chettle, D.R.; Webber, C.E.; Gordon, C.L.

    1995-01-01

    Traditionally, clinical studies of lead's effect on health have relied on blood lead levels to indicate lead exposure. However, this is unsatisfactory because blood lead levels have a half-life of approximately 5 weeks, and thus reflect recent exposure. Over 90% of the lead body burden is in bone, and it is thought to have a long residence time, thus implying that measurements of bone lead reflect cumulative exposure. So, measurements of bone lead are useful in understanding the long-term health effects of lead. Ahlgren reported the first noninvasive measurements of bone lead in humans, where γ-rays from 57 Co were used to excite the K series x-rays of lead. The lead detection system at McMaster University uses a 109 Cd source which is positioned at the center of the detector face (HPGe) and a near backscatter (∼160 degrees) geometry. This arrangement allows great flexibility, since one can sample lead in a range of different bone sites due to a robust normalization technique which eliminates the need to correct for bone geometry, thickness of overlying tissue, and other related factors. The effective radiation dose to an adult during an x-ray fluorescence bone lead measurement is extremely low, being 35 nSv. This paper addresses the issue of how bone, whole blood, and serum lead concentrations can be related in order to understand a person's lead exposure history

  6. Cumulative exergy losses associated with the production of lead metal

    Energy Technology Data Exchange (ETDEWEB)

    Szargut, J [Technical Univ. of Silesia, Gliwice (PL). Inst. of Thermal-Engineering; Morris, D R [New Brunswick Univ., Fredericton, NB (Canada). Dept. of Chemical Engineering

    1990-08-01

    Cumulative exergy losses result from the irreversibility of the links of a technological network leading from raw materials and fuels extracted from nature to the product under consideration. The sum of these losses can be apportioned into partial exergy losses (associated with particular links of the technological network) or into constituent exergy losses (associated with constituent subprocesses of the network). The methods of calculation of the partial and constituent exergy losses are presented, taking into account the useful byproducts substituting the major products of other processes. Analyses of partial and constituent exergy losses are made for the technological network of lead metal production. (author).

  7. Technical Note: SCUDA: A software platform for cumulative dose assessment

    Energy Technology Data Exchange (ETDEWEB)

    Park, Seyoun; McNutt, Todd; Quon, Harry; Wong, John; Lee, Junghoon, E-mail: rshekhar@childrensnational.org, E-mail: junghoon@jhu.edu [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 (United States); Plishker, William [IGI Technologies, Inc., College Park, Maryland 20742 (United States); Shekhar, Raj, E-mail: rshekhar@childrensnational.org, E-mail: junghoon@jhu.edu [IGI Technologies, Inc., College Park, Maryland 20742 and Sheikh Zayed Institute for Pediatric Surgical Innovation, Children’s National Health System, Washington, DC 20010 (United States)

    2016-10-15

    Purpose: Accurate tracking of anatomical changes and computation of actually delivered dose to the patient are critical for successful adaptive radiation therapy (ART). Additionally, efficient data management and fast processing are practically important for the adoption in clinic as ART involves a large amount of image and treatment data. The purpose of this study was to develop an accurate and efficient Software platform for CUmulative Dose Assessment (SCUDA) that can be seamlessly integrated into the clinical workflow. Methods: SCUDA consists of deformable image registration (DIR), segmentation, dose computation modules, and a graphical user interface. It is connected to our image PACS and radiotherapy informatics databases from which it automatically queries/retrieves patient images, radiotherapy plan, beam data, and daily treatment information, thus providing an efficient and unified workflow. For accurate registration of the planning CT and daily CBCTs, the authors iteratively correct CBCT intensities by matching local intensity histograms during the DIR process. Contours of the target tumor and critical structures are then propagated from the planning CT to daily CBCTs using the computed deformations. The actual delivered daily dose is computed using the registered CT and patient setup information by a superposition/convolution algorithm, and accumulated using the computed deformation fields. Both DIR and dose computation modules are accelerated by a graphics processing unit. Results: The cumulative dose computation process has been validated on 30 head and neck (HN) cancer cases, showing 3.5 ± 5.0 Gy (mean±STD) absolute mean dose differences between the planned and the actually delivered doses in the parotid glands. On average, DIR, dose computation, and segmentation take 20 s/fraction and 17 min for a 35-fraction treatment including additional computation for dose accumulation. Conclusions: The authors developed a unified software platform that provides

  8. The association between cumulative adversity and mental health: considering dose and primary focus of adversity.

    Science.gov (United States)

    Keinan, Giora; Shrira, Amit; Shmotkin, Dov

    2012-09-01

    The study addressed the dose-response model in the association of cumulative adversity with mental health. Data of 1,725 participants aged 50+ were drawn from the Israeli component of the Survey of Health, Ageing, and Retirement in Europe. Measures included an inventory of potentially traumatic events, distress (lifetime depression, depressive symptoms), and well-being (quality of life, optimism/hope). The maximal effect of cumulative trauma emerged in the contrast between 0-2 and 3+ events, where the higher number of events related to higher distress but also to higher well-being. While self-oriented adversity revealed no, or negative, association with well-being, other-oriented adversity revealed a positive association. The study suggests an experiential dose of cumulative adversity leading to a co-activation of distress and well-being. The source of this co-activation seems to be other-oriented adversity.

  9. Cumulant generating function formula of heat transfer in ballistic systems with lead-lead coupling

    Science.gov (United States)

    Li, Huanan; Agarwalla, Bijay Kumar; Wang, Jian-Sheng

    2012-10-01

    Based on a two-time observation protocol, we consider heat transfer in a given time interval tM in a lead-junction-lead system taking coupling between the leads into account. In view of the two-time observation, consistency conditions are carefully verified in our specific family of quantum histories. Furthermore, its implication is briefly explored. Then using the nonequilibrium Green's function method, we obtain an exact formula for the cumulant generating function for heat transfer between the two leads, valid in both transient and steady-state regimes. Also, a compact formula for the cumulant generating function in the long-time limit is derived, for which the Gallavotti-Cohen fluctuation symmetry is explicitly verified. In addition, we briefly discuss Di Ventra's repartitioning trick regarding whether the repartitioning procedure of the total Hamiltonian affects the nonequilibrium steady-state current fluctuation. All kinds of properties of nonequilibrium current fluctuations, such as the fluctuation theorem in different time regimes, could be readily given according to these exact formulas.

  10. Cumulative effective dose associated with radiography and CT of adolescents with spinal injuries.

    Science.gov (United States)

    Lemburg, Stefan P; Peters, Soeren A; Roggenland, Daniela; Nicolas, Volkmar; Heyer, Christoph M

    2010-12-01

    The purpose of this study was to analyze the quantity and distribution of cumulative effective doses in diagnostic imaging of adolescents with spinal injuries. At a level 1 trauma center from July 2003 through June 2009, imaging procedures during initial evaluation and hospitalization and after discharge of all patients 10-20 years old with spinal fractures were retrospectively analyzed. The cumulative effective doses for all imaging studies were calculated, and the doses to patients with spinal injuries who had multiple traumatic injuries were compared with the doses to patients with spinal injuries but without multiple injuries. The significance level was set at 5%. Imaging studies of 72 patients (32 with multiple injuries; average age, 17.5 years) entailed a median cumulative effective dose of 18.89 mSv. Patients with multiple injuries had a significantly higher total cumulative effective dose (29.70 versus 10.86 mSv, p cumulative effective dose to multiple injury patients during the initial evaluation (18.39 versus 2.83 mSv, p cumulative effective dose. Adolescents with spinal injuries receive a cumulative effective dose equal to that of adult trauma patients and nearly three times that of pediatric trauma patients. Areas of focus in lowering cumulative effective dose should be appropriate initial estimation of trauma severity and careful selection of CT scan parameters.

  11. Radiologic imaging in cystic fibrosis: cumulative effective dose and changing trends over 2 decades.

    LENUS (Irish Health Repository)

    O'Connell, Oisin J

    2012-06-01

    With the increasing life expectancy for patients with cystic fibrosis (CF), and a known predisposition to certain cancers, cumulative radiation exposure from radiologic imaging is of increasing significance. This study explores the estimated cumulative effective radiation dose over a 17-year period from radiologic procedures and changing trends of imaging modalities over this period.

  12. Cumulative cisplatin dose in concurrent chemoradiotherapy for head and neck cancer : A systematic review

    NARCIS (Netherlands)

    Strojan, Primoz; Vermorken, Jan B.; Beitler, Jonathan J.; Saba, Nabil F.; Haigentz, Missak; Bossi, Paolo; Worden, Francis P.; Langendijk, Johannes A.; Eisbruch, Avraham; Mendenhall, William M.; Lee, Anne W. M.; Harrison, Louis B.; Bradford, Carol R.; Smee, Robert; Silver, Carl E.; Rinaldo, Alessandra; Ferlito, Alfio

    Background. The optimal cumulative dose and timing of cisplatin administration in various concurrent chemoradiotherapy protocols for nonmetastatic head and neck squamous cell carcinoma (HNSCC) has not been determined. Methods. The absolute survival benefit at 5 years of concurrent chemoradiotherapy

  13. Evaluation of a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy

    International Nuclear Information System (INIS)

    Imae, Toshikazu; Takenaka, Shigeharu; Saotome, Naoya

    2016-01-01

    The purpose of this study was to evaluate a post-analysis method for cumulative dose distribution in stereotactic body radiotherapy (SBRT) using volumetric modulated arc therapy (VMAT). VMAT is capable of acquiring respiratory signals derived from projection images and machine parameters based on machine logs during VMAT delivery. Dose distributions were reconstructed from the respiratory signals and machine parameters in the condition where respiratory signals were without division, divided into 4 and 10 phases. The dose distribution of each respiratory phase was calculated on the planned four-dimensional CT (4DCT). Summation of the dose distributions was carried out using deformable image registration (DIR), and cumulative dose distributions were compared with those of the corresponding plans. Without division, dose differences between cumulative distribution and plan were not significant. In the condition Where respiratory signals were divided, dose differences were observed over dose in cranial region and under dose in caudal region of planning target volume (PTV). Differences between 4 and 10 phases were not significant. The present method Was feasible for evaluating cumulative dose distribution in VMAT-SBRT using 4DCT and DIR. (author)

  14. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jeong Woo; Hong, Se Mie [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of)

    2011-11-15

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  15. Analysis of Cumulative Dose to Implanted Pacemaker According to Various IMRT Delivery Methods: Optimal Dose Delivery Versus Dose Reduction Strategy

    International Nuclear Information System (INIS)

    Lee, Jeong Woo; Hong, Se Mie

    2011-01-01

    Cancer patients with implanted cardiac pacemaker occasionally require radiotherapy. Pacemaker may be damaged or malfunction during radiotherapy due to ionizing radiation or electromagnetic interference. Although radiotherapy should be planned to keep the dose to pacemaker as low as possible not to malfunction ideally, current radiation treatment planning (RTP) system does not accurately calculate deposited dose to adjacent field border or area beyond irradiated fields. In terms of beam delivery techniques using multiple intensity modulated fields, dosimetric effect of scattered radiation in high energy photon beams is required to be detailed analyzed based on measurement data. The aim of this study is to evaluate dose discrepancies of pacemaker in a RTP system as compared to measured doses. We also designed dose reduction strategy limited value of 2 Gy for radiation treatment patients with cardiac implanted pacemaker. Total accumulated dose of 145 cGy based on in-vivo dosimetry was satisfied with the recommendation criteria to prevent malfunction of pacemaker in SS technique. However, the 2 mm lead shielder enabled the scattered doses to reduce up to 60% and 40% in the patient and the phantom, respectively. The SS technique with the lead shielding could reduce the accumulated scattered doses less than 100 cGy. Calculated and measured doses were not greatly affected by the beam delivery techniques. In-vivo and measured doses on pacemaker position showed critical dose discrepancies reaching up to 4 times as compared to planned doses in RTP. The current SS technique could deliver lower scattered doses than recommendation criteria, but use of 2 mm lead shielder contributed to reduce scattered doses by 60%. The tertiary lead shielder can be useful to prevent malfunction or electrical damage of implanted pacemakers during radiotherapy. It is required to estimate more accurate scattered doses of the patient or medical device in RTP to design proper dose reduction strategy.

  16. Cumulative total effective whole-body radiation dose in critically ill patients.

    Science.gov (United States)

    Rohner, Deborah J; Bennett, Suzanne; Samaratunga, Chandrasiri; Jewell, Elizabeth S; Smith, Jeffrey P; Gaskill-Shipley, Mary; Lisco, Steven J

    2013-11-01

    Uncertainty exists about a safe dose limit to minimize radiation-induced cancer. Maximum occupational exposure is 20 mSv/y averaged over 5 years with no more than 50 mSv in any single year. Radiation exposure to the general population is less, but the average dose in the United States has doubled in the past 30 years, largely from medical radiation exposure. We hypothesized that patients in a mixed-use surgical ICU (SICU) approach or exceed this limit and that trauma patients were more likely to exceed 50 mSv because of frequent diagnostic imaging. Patients admitted into 15 predesignated SICU beds in a level I trauma center during a 30-day consecutive period were prospectively observed. Effective dose was determined using Huda's method for all radiography, CT imaging, and fluoroscopic examinations. Univariate and multivariable linear regressions were used to analyze the relationships between observed values and outcomes. Five of 74 patients (6.8%) exceeded exposures of 50 mSv. Univariate analysis showed trauma designation, length of stay, number of CT scans, fluoroscopy minutes, and number of general radiographs were all associated with increased doses, leading to exceeding occupational exposure limits. In a multivariable analysis, only the number of CT scans and fluoroscopy minutes remained significantly associated with increased whole-body radiation dose. Radiation levels frequently exceeded occupational exposure standards. CT imaging contributed the most exposure. Health-care providers must practice efficient stewardship of radiologic imaging in all critically ill and injured patients. Diagnostic benefit must always be weighed against the risk of cumulative radiation dose.

  17. Switching From Age-Based Stimulus Dosing to Dose Titration Protocols in Electroconvulsive Therapy: Empirical Evidence for Better Patient Outcomes With Lower Peak and Cumulative Energy Doses.

    Science.gov (United States)

    O'Neill-Kerr, Alex; Yassin, Anhar; Rogers, Stephen; Cornish, Janie

    2017-09-01

    The aim of this study was to test the proposition that adoption of a dose titration protocol may be associated with better patient outcomes, at lower treatment dose, and with comparable cumulative dose to that in patients treated using an age-based stimulus dosing protocol. This was an analysis of data assembled from archived records and based on cohorts of patients treated respectively on an age-based stimulus dosing protocol and on a dose titration protocol in the National Health Service in England. We demonstrated a significantly better response in the patient cohort treated with dose titration than with age-based stimulus dosing. Peak doses were less and the total cumulative dose was less in the dose titration group than in the age-based stimulus dosing group. Our findings are consistent with superior outcomes in patients treated using a dose titration protocol when compared with age-based stimulus dosing in a similar cohort of patients.

  18. Cumulative doses analysis in young trauma patients: a single-centre experience.

    Science.gov (United States)

    Salerno, Sergio; Marrale, Maurizio; Geraci, Claudia; Caruso, Giuseppe; Lo Re, Giuseppe; Lo Casto, Antonio; Midiri, Massimo

    2016-02-01

    Multidetector computed tomography (MDCT) represents the main source of radiation exposure in trauma patients. The radiation exposure of young patients is a matter of considerable medical concern due to possible long-term effects. Multiple MDCT studies have been observed in the young trauma population with an increase in radiation exposure. We have identified 249 young adult patients (178 men and 71 women; age range 14-40 years) who had received more than one MDCT study between June 2010 and June 2014. According to the International Commission on Radiological Protection publication, we have calculated the cumulative organ dose tissue-weighting factors by using CT-EXPO software(®). We have observed a mean cumulative dose of about 27 mSv (range from 3 to 297 mSv). The distribution analysis is characterised by low effective dose, below 20 mSv, in the majority of the patients. However, in 29 patients, the effective dose was found to be higher than 20 mSv. Dose distribution for the various organs analysed (breasts, ovaries, testicles, heart and eye lenses) shows an intense peak for lower doses, but in some cases high doses were recorded. Even though cumulative doses may have long-term effects, which are still under debate, high doses are observed in this specific group of young patients.

  19. Application of the ELDO approach to assess cumulative eye lens doses for interventional cardiologists

    International Nuclear Information System (INIS)

    Farah, J.; Jacob, S.; Clairand, I.; Struelens, L.; Vanhavere, F.; Auvinen, A.; Koukorava, C.; Schnelzer, M.

    2015-01-01

    In preparation of a large European epidemiological study on the relation between eye lens dose and the occurrence of lens opacities, the European ELDO project focused on the development of practical methods to estimate retrospectively cumulative eye lens dose for interventional medical professionals exposed to radiation. The present paper applies one of the ELDO approaches, correlating eye lens dose to whole-body doses, to assess cumulative eye lens dose for 14 different Finnish interventional cardiologists for whom annual whole-body dose records were available for their entire working period. The estimated cumulative left and right eye lens dose ranged from 8 to 264 mSv and 6 to 225 mSv, respectively. In addition, calculations showed annual eye lens doses sometimes exceeding the new ICRP annual limit of 20 mSv. The work also highlights the large uncertainties associated with the application of such an approach proving the need for dedicated dosimetry systems in the routine monitoring of the eye lens dose. (authors)

  20. TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

    Energy Technology Data Exchange (ETDEWEB)

    Bostani, M; Cagnon, C; Sepahdari, A; Beckett, K; Oshiro, T; McNitt-Gray, M [UCLA School of Medicine, Los Angeles, CA (United States)

    2016-06-15

    Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv and above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement

  1. TH-AB-207A-04: Assessment of Patients’ Cumulative Effective Dose From CT Examinations

    International Nuclear Information System (INIS)

    Bostani, M; Cagnon, C; Sepahdari, A; Beckett, K; Oshiro, T; McNitt-Gray, M

    2016-01-01

    Purpose: The Joint Commission requires institutions to consider patient’s age and recent imaging exams when deciding on the most appropriate type of imaging exam. Additionally, knowing patient’s imaging history can help prevent duplicate scans. Radiation dose management software affords new opportunities to identify and utilize patients with high cumulative doses as one proxy for subsequent review of imaging history and opportunities in avoiding redundant exams. Methods: Using dose management software (Radimetrics, Bayer Healthcare) a total of 72073 CT examinations performed from Jan 2015 to Jan 2016 were examined to categorize patients with a cumulative effective dose of 100 mSv and above. This threshold was selected based on epidemiological studies on populations exposed to radiation, which demonstrate a statistical increase of cancer risk at doses above 100 mSv. Histories of patients with highest cumulative dose and highest number of exams were further investigated by a Radiologist for appropriateness of recurrent studies and potential opportunities for reduction. Results: Out of 34762 patients, 927 (2.7%) were identified with a cumulative dose of 100 mSv and above. The highest cumulative dose (842 mSv) belonged to an oncology patient who underwent 2 diagnostic exams and 9 interventional ablative CT guided procedures. The patient with highest number of exams (56 counts) and cumulative dose of 170 mSv was a 17 year old trauma patient. An imaging history review of these two patients did not suggest any superfluous scans. Conclusion: Our limited pilot study suggests that recurrent CT exams for patients with oncologic or severe trauma history may be warranted and appropriate. As a result, for future studies we will be focusing on high dose patient cohorts not associated with oncology or severe trauma. Additionally, the review process itself has suggested areas for potential improvement in patient care, including improved documentation and Radiologist involvement

  2. Cumulant generating function formula of heat transfer in ballistic systems with lead-lead coupling and general nonlinear systems

    Science.gov (United States)

    Li, Huanan

    2013-03-01

    Based on a two-time observation protocol, we consider heat transfer in a given time interval tM in a lead-junction-lead system taking coupling between the leads into account. In view of the two-time observation, consistency conditions are carefully verified in our specific family of quantum histories. Furthermore, its implication is briefly explored. Then using the nonequilibrium Green's function method, we obtain an exact formula for the cumulant generating function for heat transfer between the two leads, valid in both transient and steady-state regimes. Also, a compact formula for the cumulant generating function in the long-time limit is derived, for which the Gallavotti-Cohen fluctuation symmetry is explicitly verified. In addition, we briefly discuss Di Ventra's repartitioning trick regarding whether the repartitioning procedure of the total Hamiltonian affects the nonequilibrium steady-state current fluctuation. All kinds of properties of nonequilibrium current fluctuations, such as the fluctuation theorem in different time regimes, could be readily given according to these exact formulas. Finally a practical formalism dealing with cumulants of heat transfer across general nonlinear quantum systems is established based on field theoretical/algebraic method.

  3. Patterns of prednisone use during pregnancy in women with rheumatoid arthritis: Daily and cumulative dose.

    Science.gov (United States)

    Palmsten, Kristin; Rolland, Matthieu; Hebert, Mary F; Clowse, Megan E B; Schatz, Michael; Xu, Ronghui; Chambers, Christina D

    2018-04-01

    To characterize prednisone use in pregnant women with rheumatoid arthritis using individual-level heat-maps and clustering individual trajectories of prednisone dose, and to evaluate the association between prednisone dose trajectory groups and gestational length. This study included pregnant women with rheumatoid arthritis who enrolled in the MotherToBaby Autoimmune Diseases in Pregnancy Study (2003-2014) before gestational week 20 and reported prednisone use without another oral glucocorticoid during pregnancy (n = 254). Information on medication use and pregnancy outcomes was collected by telephone interview plus by medical record review. Prednisone daily dose and cumulative dose were plotted by gestational day using a heat map for each individual. K-means clustering was used to cluster individual trajectories of prednisone dose into groups. The associations between trajectory group and demographics, disease severity measured by the Health Assessment Questionnaire at enrollment, and gestational length were evaluated. Women used prednisone 3 to 292 days during pregnancy, with daily doses ranging from <1 to 60 mg. Total cumulative dose ranged from 8 to 6225 mg. Disease severity, non-biologic disease modifying anti-rheumatic drug use, and gestational length varied significantly by trajectory group. After adjusting for disease severity, non-biologic disease modifying anti-rheumatic drug use, and other covariates, the highest vs lowest daily dose trajectory group was associated with reduced gestational age at delivery (β: -2.3 weeks (95%: -3.4, -1.3)), as was the highest vs lowest cumulative dose trajectory group (β: -2.6 weeks (95%: -3.6, -1.5)). In pregnant women with rheumatoid arthritis, patterns of higher prednisone dose were associated with shorter gestational length compared with lower dose. Copyright © 2018 John Wiley & Sons, Ltd.

  4. Lead-Related Genetic Loci, Cumulative Lead Exposure and Incident Coronary Heart Disease: The Normative Aging Study

    Science.gov (United States)

    Weisskopf, Marc G.; Sparrow, David; Schwartz, Joel; Hu, Howard; Park, Sung Kyun

    2016-01-01

    Background Cumulative exposure to lead is associated with cardiovascular outcomes. Polymorphisms in the δ-aminolevulinic acid dehydratase (ALAD), hemochromatosis (HFE), heme oxygenase-1 (HMOX1), vitamin D receptor (VDR), glutathione S-transferase (GST) supergene family (GSTP1, GSTT1, GSTM1), apolipoprotein E (APOE),angiotensin II receptor-1 (AGTR1) and angiotensinogen (AGT) genes, are believed to alter toxicokinetics and/or toxicodynamics of lead. Objectives We assessed possible effect modification by genetic polymorphisms in ALAD, HFE, HMOX1, VDR, GSTP1, GSTT1, GSTM1, APOE, AGTR1 and AGT individually and as the genetic risk score (GRS) on the association between cumulative lead exposure and incident coronary heart disease (CHD) events. Methods We used K-shell-X-ray fluorescence to measure bone lead levels. GRS was calculated on the basis of 22 lead-related loci. We constructed Cox proportional hazard models to compute adjusted hazard ratios (HRs) and 95% confidence intervals (CIs) for incident CHD. We applied inverse probability weighting to account for potential selection bias due to recruitment into the bone lead sub-study. Results Significant effect modification was found by VDR, HMOX1, GSTP1, APOE, and AGT genetic polymorphisms when evaluated individually. Further, the bone lead-CHD associations became larger as GRS increases. After adjusting for potential confounders, a HR of CHD was 2.27 (95%CI: 1.50–3.42) with 2-fold increase in patella lead levels, among participants in the top tertile of GRS. We also detected an increasing trend in HRs across tertiles of GRS (p-trend = 0.0063). Conclusions Our findings suggest that lead-related loci as a whole may play an important role in susceptibility to lead-related CHD risk. These findings need to be validated in a separate cohort containing bone lead, lead-related genetic loci and incident CHD data. PMID:27584680

  5. Cumulative effective and individual organ dose levels in paediatric patients undergoing multiple catheterizations for congenital heart disease

    International Nuclear Information System (INIS)

    Jones, T.P.; Brennan, P.C.; Ryan, E.

    2017-01-01

    This study examines the cumulative radiation dose levels received by a group of children who underwent multiple cardiac catheterisation procedures during the investigation and management of congenital heart disease (CHD). The purpose is to calculate cumulative doses, identify higher dose individuals, outline the inconsistencies with risk assessment and encourage the establishment of dose databases in order to facilitate the longitudinal research necessary to better understand health risks. A retrospective review of patient records for 117 paediatric patients who have undergone two or more cardiac catheterizations for the investigation of CHD was undertaken. This cohort consisted of patients who were catheterised over a period from September 2002 to August 2014. The age distribution was from newborn to 17 y. Archived kerma-area product (P KA ) and fluoroscopy time (T) readings were retrieved and analysed. Cumulative effective and individual organ doses were determined. The cumulative P KA levels ranged from 1.8 to 651.2 Gycm 2 , whilst cumulative effective dose levels varied from 2 to 259 mSv. The cumulative fluoroscopy time was shown to vary from 8.1 to 193.5 min. Median cumulative organ doses ranged from 3 to 94 mGy. Cumulative effective dose levels are highly variable but may exceed 250 mSv. Individual organ and effective dose measurements remain useful for comparison purposes between institutions although current methodologies used for determining lifetime risks are inadequate. (authors)

  6. Accurate convolution/superposition for multi-resolution dose calculation using cumulative tabulated kernels

    International Nuclear Information System (INIS)

    Lu Weiguo; Olivera, Gustavo H; Chen Mingli; Reckwerdt, Paul J; Mackie, Thomas R

    2005-01-01

    Convolution/superposition (C/S) is regarded as the standard dose calculation method in most modern radiotherapy treatment planning systems. Different implementations of C/S could result in significantly different dose distributions. This paper addresses two major implementation issues associated with collapsed cone C/S: one is how to utilize the tabulated kernels instead of analytical parametrizations and the other is how to deal with voxel size effects. Three methods that utilize the tabulated kernels are presented in this paper. These methods differ in the effective kernels used: the differential kernel (DK), the cumulative kernel (CK) or the cumulative-cumulative kernel (CCK). They result in slightly different computation times but significantly different voxel size effects. Both simulated and real multi-resolution dose calculations are presented. For simulation tests, we use arbitrary kernels and various voxel sizes with a homogeneous phantom, and assume forward energy transportation only. Simulations with voxel size up to 1 cm show that the CCK algorithm has errors within 0.1% of the maximum gold standard dose. Real dose calculations use a heterogeneous slab phantom, both the 'broad' (5 x 5 cm 2 ) and the 'narrow' (1.2 x 1.2 cm 2 ) tomotherapy beams. Various voxel sizes (0.5 mm, 1 mm, 2 mm, 4 mm and 8 mm) are used for dose calculations. The results show that all three algorithms have negligible difference (0.1%) for the dose calculation in the fine resolution (0.5 mm voxels). But differences become significant when the voxel size increases. As for the DK or CK algorithm in the broad (narrow) beam dose calculation, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 10% (7%) of the maximum dose. As for the broad (narrow) beam dose calculation using the CCK algorithm, the dose differences between the 0.5 mm voxels and the voxels up to 8 mm (4 mm) are around 1% of the maximum dose. Among all three methods, the CCK algorithm

  7. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline.

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-10-01

    To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis) 4.5 microg (F4.5) or terbutaline (Bricanyl) 500 microg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Formoterol and terbutaline had significant beta2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48-3.65) mmol l(-1) on the day of no treatment to 2.98 (CI: 2.90-3.08) after 10 x F4.5 and 2.70 (CI: 2.61-2.78) mmol l(-1) after 10 x T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422-435) ms on the day of no treatment, to 455 (CI: 448-462) ms after 10 x F4.5 and 470 (CI: 463-476) ms after 10 x T500. Estimates of relative dose potency indicated that F4.5 microg had the same systemic activity as the clinically less effective dose of 250 microg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 microg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h. Multiple inhalations over 2.5 h of

  8. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6–11 years-old than cumulative high doses of inhaled terbutaline

    Science.gov (United States)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören; Nordvall, S Lennart; Pedroletti, Christophe; Bengtsson, Thomas; Johannes-Hellberg, Ingegerd; Rosenborg, Johan

    2004-01-01

    Objectives To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. Methods Twenty boys and girls (6–11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxis®) 4.5 µg (F4.5) or terbutaline (Bricanyl®) 500 µg (T500) were inhaled cumulatively via a dry powder inhaler (Turbuhaler®) over 1 h (three patients) or 2.5 h (17 patients) and compared to a day of no treatment, in a randomised, double-blind (active treatments only), crossover trial. Blood pressure (BP), ECG, plasma potassium, glucose, lactate, and adverse events were monitored up to 10 h to assess tolerability and relative systemic dose potency. Results Formoterol and terbutaline had significant β2-adrenergic effects on most outcomes. Apart from the effect on systolic BP, QRS duration and PR interval, the systemic effects were significantly more pronounced with terbutaline than with formoterol. Thus, mean minimum plasma potassium, was suppressed from 3.56 (95% confidence interval, CI: 3.48–3.65) mmol l−1 on the day of no treatment to 2.98 (CI: 2.90–3.08) after 10 × F4.5 and 2.70 (CI: 2.61–2.78) mmol l−1 after 10 × T500, and maximum Q-Tc (heart rate corrected Q-T interval [Bazett's formula]) was prolonged from 429 (CI: 422–435) ms on the day of no treatment, to 455 (CI: 448–462) ms after 10 × F4.5 and 470 (CI: 463–476) ms after 10 × T500. Estimates of relative dose potency indicated that F4.5 µg had the same systemic activity as the clinically less effective dose of 250 µg terbutaline. The duration of systemic effects differed marginally between treatments. Spontaneously reported adverse events (most frequently tremor) were fewer with formoterol (78% of the children) than with terbutaline (95%). A serious adverse event occurred after inhalation of 45 µg formoterol over the 1 h dosing time, that prompted the extension of dosing time to 2.5 h

  9. Low Birth Weight, Cumulative Obesity Dose, and the Risk of Incident Type 2 Diabetes

    OpenAIRE

    Feng, Cindy; Osgood, Nathaniel D.; Dyck, Roland F.

    2018-01-01

    Background. Obesity history may provide a better understanding of the contribution of obesity to T2DM risk. Methods. 17,634 participants from the 1958 National Child Development Study were followed from birth to 50 years. Cumulative obesity dose, a measure of obesity history, was calculated by subtracting the upper cut-off of the normal BMI from the actual BMI at each follow-up and summing the areas under the obesity dose curve. Hazard ratios (HRs) for diabetes were calculated using Cox regre...

  10. Localized accumulation of lead within and among bones from lead-dosed goats

    International Nuclear Information System (INIS)

    Cretacci, Yan; Parsons, Patrick J.

    2010-01-01

    The principal aim of this study was to gain a better understanding of where lead (Pb) accumulates and how it is distributed, within the bones of dosed goats. Adult goats were periodically dosed with Pb over a number of years for the primary purpose of producing blood pools containing endogenously bound Pb, for the New York State Blood Lead Proficiency Testing Program. Bone samples (e.g., primarily tibia, femur, humerus, and radius) were collected post-mortem from 11 animals and were analyzed for Pb content by acid digestion and electrothermal atomic absorption spectrometry (ETAAS or GFAAS). Average tibia Pb levels were found to correlate strongly with the cumulative Pb dose (r 2 =0.81). However, the concentration of Pb in different bones and even within a small area of the same bone varied tremendously. Blood-rich trabecular (spongy) bone, such as the patella and calcaneus, were much more enriched in Pb than was cortical (compact) bone. In some dosed animals, the Pb concentration in the tibia was markedly higher at the proximal and distal ends of the bone compared to the mid-shaft. The implications of these findings with regard to the noninvasive measurement of lead in bone by XRF methods are discussed.

  11. Localized accumulation of lead within and among bones from lead-dosed goats

    Energy Technology Data Exchange (ETDEWEB)

    Cretacci, Yan [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, P.O. Box 509, Albany, NY 12201-0509 (United States); Department of Environmental Health Sciences, School of Public Health, The University at Albany, P.O. Box 509, Albany, NY 12201-0509 (United States); Parsons, Patrick J., E-mail: pparsons@wadsworth.org [Laboratory of Inorganic and Nuclear Chemistry, Wadsworth Center, New York State Department of Health, P.O. Box 509, Albany, NY 12201-0509 (United States); Department of Environmental Health Sciences, School of Public Health, The University at Albany, P.O. Box 509, Albany, NY 12201-0509 (United States)

    2010-01-15

    The principal aim of this study was to gain a better understanding of where lead (Pb) accumulates and how it is distributed, within the bones of dosed goats. Adult goats were periodically dosed with Pb over a number of years for the primary purpose of producing blood pools containing endogenously bound Pb, for the New York State Blood Lead Proficiency Testing Program. Bone samples (e.g., primarily tibia, femur, humerus, and radius) were collected post-mortem from 11 animals and were analyzed for Pb content by acid digestion and electrothermal atomic absorption spectrometry (ETAAS or GFAAS). Average tibia Pb levels were found to correlate strongly with the cumulative Pb dose (r{sup 2}=0.81). However, the concentration of Pb in different bones and even within a small area of the same bone varied tremendously. Blood-rich trabecular (spongy) bone, such as the patella and calcaneus, were much more enriched in Pb than was cortical (compact) bone. In some dosed animals, the Pb concentration in the tibia was markedly higher at the proximal and distal ends of the bone compared to the mid-shaft. The implications of these findings with regard to the noninvasive measurement of lead in bone by XRF methods are discussed.

  12. Cumulative Training Dose's Effects on Interrelationships Between Common Training-Load Models During Basketball Activity.

    Science.gov (United States)

    Scanlan, Aaron T; Fox, Jordan L; Borges, Nattai R; Dascombe, Ben J; Dalbo, Vincent J

    2017-02-01

    The influence of various factors on training-load (TL) responses in basketball has received limited attention. This study aimed to examine the temporal changes and influence of cumulative training dose on TL responses and interrelationships during basketball activity. Ten state-level Australian male junior basketball players completed 4 × 10-min standardized bouts of simulated basketball activity using a circuit-based protocol. Internal TL was quantified using the session rating of perceived exertion (sRPE), summated heart-rate zones (SHRZ), Banister training impulse (TRIMP), and Lucia TRIMP models. External TL was assessed via measurement of mean sprint and circuit speeds. Temporal TL comparisons were performed between 10-min bouts, while Pearson correlation analyses were conducted across cumulative training doses (0-10, 0-20, 0-30, and 0-40 min). sRPE TL increased (P basketball activity. sRPE TL was only significantly related to Lucia TRIMP (r = .66-.69; P basketball training doses lasting beyond 20 min. Thus, the interchangeability of commonly used internal and external TL approaches appears dose-dependent during basketball activity, with various psychophysiological mediators likely underpinning temporal changes.

  13. Association of cumulative dose of haloperidol with next-day delirium in older medical ICU patients.

    Science.gov (United States)

    Pisani, Margaret A; Araujo, Katy L B; Murphy, Terrence E

    2015-05-01

    To evaluate the association between cumulative dose of haloperidol and next-day diagnosis of delirium in a cohort of older medical ICU patients, with adjustment for its time-dependent confounding with fentanyl and intubation. Prospective, observational study. Medical ICU at an urban, academic medical center. Age 60 years and older admitted to the medical ICU who received at least one dose of haloperidol (n = 93). Of these, 72 patients were intubated at some point in their medical ICU stay, whereas 21 were never intubated. None. Detailed data were collected concerning time, dosage, route of administration of all medications, as well as for important clinical covariates, and daily status of intubation and delirium using the confusion assessment method for the ICU and a chart-based algorithm. Among nonintubated patients, and after adjustment for time-dependent confounding and important covariates, each additional cumulative milligram of haloperidol was associated with 5% higher odds of next-day delirium with odds ratio of 1.05 (credible interval [CI], 1.02-1.09). After adjustment for time-dependent confounding and covariates, intubation was associated with a five-fold increase in odds of next-day delirium with odds ratio of 5.66 (CI, 2.70-12.02). Cumulative dose of haloperidol among intubated patients did not change their already high likelihood of next-day delirium. After adjustment for time-dependent confounding, the positive associations between indicators of intubation and of cognitive impairment and next-day delirium became stronger. These results emphasize the need for more studies regarding the efficacy of haloperidol for treatment of delirium among older medical ICU patients and demonstrate the value of assessing nonintubated patients.

  14. Method for calculating individual equivalent doses and cumulative dose of population in the vicinity of nuclear power plant site

    International Nuclear Information System (INIS)

    Namestek, L.; Khorvat, D; Shvets, J.; Kunz, Eh.

    1976-01-01

    A method of calculating the doses of external and internal person irradiation in the nuclear power plant vicinity under conditions of normal operation and accident situations has been described. The main difference between the above method and methods used up to now is the use of a new antropomorphous representation of a human body model together with all the organs. The antropomorphous model of human body and its organs is determined as a set of simple solids, coordinates of disposistion of the solids, sizes, masses, densities and composition corresponding the genuine organs. The use of the Monte-Carlo method is the second difference. The results of the calculations according to the model suggested can be used for determination: a critical group of inhabitans under conditions of normal plant operation; groups of inhabitants most subjected to irradiation in the case of possible accident; a critical sector with a maximum collective dose in the case of an accident; a critical radioisotope favouring the greatest contribution to an individual equivalent dose; critical irradiation ways promoting a maximum contribution to individual equivalent doses; cumulative collective doses for the whole region or for a chosen part of the region permitting to estimate a population dose. The consequent method evoluation suggests the development of separate units of the calculationg program, critical application and the selection of input data of physical, plysiological and ecological character and improvement of the calculated program for the separate concrete events [ru

  15. Pharmacoepidemiology of opiate use in the neonatal ICU: Increasing cumulative doses and iatrogenic opiate withdrawal.

    Science.gov (United States)

    Lewis, Tamorah; Erfe, Betty Luan; Ezell, Tarrah; Gauda, Estelle

    2015-01-01

    Neonatal intensive care unit (ICU) care involves use of opiates to treat postoperative, ventilated, or chronically ill infants. Opiates provide necessary analgesia and sedation, but the morbidities include prolonged neonatal abstinence syndrome (NAS) and extended length of stay for dose tapering. Our objective was to quantify trends in opiate exposure in a tertiary care NICU. The authors hypothesize that medical opiate exposure and resultant ICU-acquired NAS would increase over time. Retrospective cross-sectional cohort study. Tertiary care NICU. High-risk inborn infants admitted in fiscal years 2003-2004, 2007-2008, and 2010-2011. Average cumulative morphine exposure (all opiate doses converted to morphine equivalents) per time epoch was compared in cohorts of clinically similar infants. Linear regression was used to assess the primary outcome, assessing changes in opiate exposure over time. Sixty-three infants were included in the final analysis. The primary analysis assessing cumulative opiate exposure per infant showed an increase of 134 mg per time epoch (95% CI-12, 279 mg, p-value 0.071). There was a statistically significant increase in the percent of infants with a diagnosis of iatrogenic NAS, increasing from 9 to 35 to 50 percent (p-value 0.012).

  16. Cumulative radiation dose caused by radiologic studies in critically ill trauma patients.

    Science.gov (United States)

    Kim, Patrick K; Gracias, Vicente H; Maidment, Andrew D A; O'Shea, Michael; Reilly, Patrick M; Schwab, C William

    2004-09-01

    Critically ill trauma patients undergo many radiologic studies, but the cumulative radiation dose is unknown. The purpose of this study was to estimate the cumulative effective dose (CED) of radiation resulting from radiologic studies in critically ill trauma patients. The study group was composed of trauma patients at an urban Level I trauma center with surgical intensive care unit length of stay (LOS) greater than 30 days. The radiology records were reviewed. A typical effective dose per study for each type of plain film radiograph, computed tomographic scan, fluoroscopic study, and nuclear medicine study was used to calculate CED. Forty-six patients met criteria. The mean surgical intensive care unit and hospital LOS were 42.7 +/- 14.0 and 59.5 +/- 28.5 days, respectively. The mean Injury Severity Score was 32.2 +/- 15.0. The mean number of studies per patient was 70.1 +/- 29.0 plain film radiographs, 7.8 +/- 4.1 computed tomographic scans, 2.5 +/- 2.6 fluoroscopic studies, and 0.065 +/- 0.33 nuclear medicine study. The mean CED was 106 +/- 59 mSv per patient (range, 11-289 mSv; median, 104 mSv). Among age, mechanism, Injury Severity Score, and LOS, there was no statistically significant predictor of high CED. The mean CED in the study group was 30 times higher than the average yearly radiation dose from all sources for individuals in the United States. The theoretical additional morbidity attributable to radiologic studies was 0.78%. From a radiobiologic perspective, risk-to-benefit ratios of radiologic studies are favorable, given the importance of medical information obtained. Current practice patterns regarding use of radiologic studies appear to be acceptable.

  17. Age- and gender-specific estimates of cumulative CT dose over 5 years using real radiation dose tracking data in children

    International Nuclear Information System (INIS)

    Lee, Eunsol; Goo, Hyun Woo; Lee, Jae-Yeong

    2015-01-01

    It is necessary to develop a mechanism to estimate and analyze cumulative radiation risks from multiple CT exams in various clinical scenarios in children. To identify major contributors to high cumulative CT dose estimates using actual dose-length product values collected for 5 years in children. Between August 2006 and July 2011 we reviewed 26,937 CT exams in 13,803 children. Among them, we included 931 children (median age 3.5 years, age range 0 days-15 years; M:F = 533:398) who had 5,339 CT exams. Each child underwent at least three CT scans and had accessible radiation dose reports. Dose-length product values were automatically extracted from DICOM files and we used recently updated conversion factors for age, gender, anatomical region and tube voltage to estimate CT radiation dose. We tracked the calculated CT dose estimates to obtain a 5-year cumulative value for each child. The study population was divided into three groups according to the cumulative CT dose estimates: high, ≥30 mSv; moderate, 10-30 mSv; and low, <10 mSv. We reviewed clinical data and CT protocols to identify major contributors to high and moderate cumulative CT dose estimates. Median cumulative CT dose estimate was 5.4 mSv (range 0.5-71.1 mSv), and median number of CT scans was 4 (range 3-36). High cumulative CT dose estimates were most common in children with malignant tumors (57.9%, 11/19). High frequency of CT scans was attributed to high cumulative CT dose estimates in children with ventriculoperitoneal shunt (35 in 1 child) and malignant tumors (range 18-49). Moreover, high-dose CT protocols, such as multiphase abdomen CT (median 4.7 mSv) contributed to high cumulative CT dose estimates even in children with a low number of CT scans. Disease group, number of CT scans, and high-dose CT protocols are major contributors to higher cumulative CT dose estimates in children. (orig.)

  18. Repeated Radionuclide therapy in metastatic paraganglioma leading to the highest reported cumulative activity of 131I-MIBG

    International Nuclear Information System (INIS)

    Ezziddin, Samer; Sabet, Amir; Ko, Yon-Dschun; Xun, Sunny; Matthies, Alexander; Biersack, Hans-Jürgen

    2012-01-01

    131 I-MIBG therapy for neuroendocrine tumours may be dose limited. The common range of applied cumulative activities is 10-40 GBq. We report the uneventful cumulative administration of 111 GBq (= 3 Ci) 131 I-MIBG in a patient with metastatic paraganglioma. Ten courses of 131 I-MIBG therapy were given within six years, accomplishing symptomatic, hormonal and tumour responses with no serious adverse effects. Chemotherapy with cisplatin/vinblastine/dacarbazine was the final treatment modality with temporary control of disease, but eventually the patient died of progression. The observed cumulative activity of 131 I-MIBG represents the highest value reported to our knowledge, and even though 12.6 GBq of 90 Y-DOTATOC were added intermediately, no associated relevant bone marrow, hepatic or other toxicity were observed. In an individual attempt to palliate metastatic disease high cumulative activity alone should not preclude the patient from repeat treatment

  19. Cumulative Lung Dose for Several Motion Management Strategies as a Function of Pretreatment Patient Parameters

    International Nuclear Information System (INIS)

    Hugo, Geoffrey D.; Campbell, Jonathon; Zhang Tiezhi; Yan Di

    2009-01-01

    Purpose: To evaluate patient parameters that may predict for relative differences in cumulative four-dimensional (4D) lung dose among several motion management strategies. Methods and Materials: Deformable image registration and dose accumulation were used to generate 4D treatment plans for 18 patients with 4D computed tomography scans. Three plans were generated to simulate breath hold at normal inspiration, target tracking with the beam aperture, and mid-ventilation aperture (control of the target at the mean daily position and application of an iteratively computed margin to compensate for respiration). The relative reduction in mean lung dose (MLD) between breath hold and mid-ventilation aperture (ΔMLD BH ) and between target tracking and mid-ventilation aperture (ΔMLD TT ) was calculated. Associations between these two variables and parameters of the lesion (excursion, size, location, and deformation) and dose distribution (local dose gradient near the target) were also calculated. Results: The largest absolute and percentage differences in MLD were 1.0 Gy and 21.5% between breath hold and mid-ventilation aperture. ΔMLD BH was significantly associated (p TT was significantly associated with excursion, deformation, and local dose gradient. A linear model was constructed to represent ΔMLD vs. excursion. For each 5 mm of excursion, target tracking reduced the MLD by 4% compared with the results of a mid-ventilation aperture plan. For breath hold, the reduction was 5% per 5 mm of excursion. Conclusions: The relative difference in MLD among different motion management strategies varied with patient and tumor characteristics for a given dosimetric target coverage. Tumor excursion is useful to aid in stratifying patients according to appropriate motion management strategies.

  20. Negative impact of high cumulative glucocorticoid dose on bone metabolism of patients with myasthenia gravis.

    Science.gov (United States)

    Braz, Nayara Felicidade Tomaz; Rocha, Natalia Pessoa; Vieira, Érica Leandro Marciano; Gomez, Rodrigo Santiago; Barbosa, Izabela Guimarães; Malheiro, Olívio Brito; Kakehasi, Adriana Maria; Teixeira, Antonio Lucio

    2017-08-01

    This current study aimed to evaluate the frequency of low bone mass, osteopenia, and osteoporosis in patients with myasthenia gravis (MG) and to investigate the possible association between bone mineral density (BMD) and plasma levels of bone metabolism markers. Eighty patients with MG and 62 controls BMD were measured in the right femoral neck and lumbar spine by dual-energy X-ray absorptiometry. Plasma concentrations of osteocalcin, osteopontin, osteoprotegerin, tumor necrosis factor (TNF-α), interleukin (IL)-1β, IL-6, dickkopf (DKK-1), sclerostin, insulin, leptin, adrenocorticotropic hormone, parathyroid hormone, and fibroblast growth factor (FGF-23) were analyzed by Luminex®. The mean age of patients was 41.9 years, with 13.5 years of length of illness, and a mean cumulative dose of glucocorticoids 38,123 mg. Patients had significant reduction in BMD of the lumbar, the femoral neck, and in the whole body when compared with controls. Fourteen percent MG patients had osteoporosis at the lumbar spine and 2.5% at the femoral neck. In comparison with controls, patients with MG presented lower levels of osteocalcin, adrenocorticotropic hormone, parathyroid hormone, sclerostin, TNF-α, and DKK-1 and higher levels of FGF-23, leptin, and IL-6. There was a significant negative correlation between cumulative glucocorticoid dose and serum calcium, lumbar spine T-score, femoral neck BMD, T-score, and Z-score. After multivariate analysis, higher TNF-α levels increased the likelihood of presenting low bone mass by 2.62. MG patients under corticotherapy presented low BMD and altered levels of bone markers.

  1. Prediction of the cumulated dose for external beam irradiation of prostate cancer patients with 3D-CRT technique

    Directory of Open Access Journals (Sweden)

    Giżyńska Marta

    2016-03-01

    Full Text Available Nowadays in radiotherapy, much effort is taken to minimize the irradiated volume and consequently minimize doses to healthy tissues. In our work, we tested the hypothesis that the mean dose distribution calculated from a few first fractions can serve as prediction of the cumulated dose distribution, representing the whole treatment. We made our tests for 25 prostate cancer patients treated with three orthogonal fields technique. We did a comparison of dose distribution calculated as a sum of dose distribution from each fraction with a dose distribution calculated with isocenter shifted for a mean setup error from a few first fractions. The cumulative dose distribution and predicted dose distributions are similar in terms of gamma (3 mm 3% analysis, under condition that we know setup error from seven first fractions. We showed that the dose distribution calculated for the original plan with the isocenter shifted to the point, defined as the original isocenter corrected of the mean setup error estimated from the first seven fractions supports our hypothesis, i.e. can serve as a prediction for cumulative dose distribution.

  2. Cumulative high doses of inhaled formoterol have less systemic effects in asthmatic children 6-11 years-old than cumulative high doses of inhaled terbutaline

    DEFF Research Database (Denmark)

    Kaae, Rikke; Agertoft, Lone; Pedersen, Sören

    2004-01-01

    OBJECTIVES: To evaluate high dose tolerability and relative systemic dose potency between inhaled clinically equipotent dose increments of formoterol and terbutaline in children. METHODS: Twenty boys and girls (6-11 years-old) with asthma and normal ECGs were studied. Ten doses of formoterol (Oxi...

  3. A personal radio-frequency dosimeter with cumulative-dose recording capabilities

    International Nuclear Information System (INIS)

    Rochelle, R.W.; Moore, M.R.; Thomas, R.S.; Ewing, P.D.; Hess, R.A.; Hoffheins, B.S.

    1990-01-01

    The radio-frequency (rf) dosimeter developed by the Oak Ridge National Laboratory is a portable, pocket-sized cumulative-dose recording device designed to detect and record the strengths and durations of electric fields present in the work areas of naval vessels. The device measures an integrated dose and records the electric fields that exceed the permissible levels set by the American National Standards Institute. Features of the rf dosimeter include a frequency range of 30 MHz to 10 GHz and a three-dimensional sensor. Data obtained with the rf dosimeter will be used to determine the ambient field-strength profile for shipboard personnel over an extended time. Readings are acquired and averaged over a 6-min period corresponding to the rise time of the core body temperature. These values are stored for up to 6 months, after which the data are transferred to a computer via the dosimeter's serial port. The rf dosimeter should increase knowledge of the levels of electric fields to which individuals are exposed. 13 refs., 16 figs., 2 tabs

  4. Cumulative effective dose associated with computed tomography examinations in adolescent trauma patients.

    Science.gov (United States)

    Choi, Seung Joon; Kim, Eun Young; Kim, Hyung Sik; Choi, Hye-Young; Cho, Jinseong; Yang, Hyuk Jun; Chung, Yong Eun

    2014-07-01

    The aims of this study were to analyze cumulative effective dose (cED) and to assess lifetime attributable risk (LAR) of cancer due to radiation exposure during computed tomography (CT) examinations in adolescent trauma patients. Between January 2010 and May 2011, the adolescent patients with trauma were enrolled in this study. Numbers of CT examinations and body regions examined were collated, and cEDs were calculated using dose-length product values and conversion factors. Lifetime attributable risk for cancer incidence and cancer-associated mortality were quantified based on the studies of survivors of the atomic bombs on Japan. Data were stratified according to severity of trauma: minor trauma, injury severity score of less than 16; and major trauma, injury severity score of 16 or greater. A total of 698 CT scans were obtained on the following regions of 484 adolescent patients: head CT, n = 647; rest of the body, n = 41; and thorax, n = 10. Mean cED per patient was 3.4 mSv, and mean LARs for cancer incidence and mortality were 0.05% and 0.02%, respectively. The majority of patients (98.4%) experienced minor trauma, and their mean cED and LARs for cancer incidence and mortality (3.0 mSv and 0.04% and 0.02%, respectively) were significantly lower than those of patients with major trauma (24.3 mSv and 0.31% and 0.15%, respectively, all P values trauma was found to be relatively low in adolescent patients. However, adolescent patients with major trauma were exposed to a substantial amount of radiation during multiple CT examinations.

  5. Re-irradiation: Outcome, cumulative dose and toxicity in patients retreated with stereotactic radiotherapy in the abdominal or pelvic region

    NARCIS (Netherlands)

    H. Abusaris (Huda); M.S. Hoogeman (Mischa); J.J.M.E. Nuyttens (Joost)

    2012-01-01

    textabstractThe purpose of the present study was to explore the outcome, cumulative dose in tumor and organs at risk and toxicity after extra-cranial stereotactic re-irradiation. Twenty-seven patients were evaluated who had been re-irradiated with stereotactic body radiotherapy (SBRT) after

  6. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    Energy Technology Data Exchange (ETDEWEB)

    Johnsen, Boel [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); Fasmer, Kristine Eldevik [Haukeland University Hospital, Department of Oncology, Medical Physics Section, Bergen (Norway); Boye, Kjetil [Norwegian Radium Hospital, Oslo University Hospital, Department of Oncology, Oslo (Norway); Rosendahl, Karen; Aukland, Stein Magnus [Haukeland University Hospital, Department of Radiology, Paediatric Section, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway); Trovik, Clement [University of Bergen, Department of Clinical Medicine, Bergen (Norway); Haukeland University Hospital, Department of Surgery, Orthopaedic Section, Bergen (Norway); Biermann, Martin [Haukeland University Hospital, Centre for Nuclear Medicine and PET, Department of Radiology, P.O. Box 1400, Bergen (Norway); University of Bergen, Department of Clinical Medicine, Bergen (Norway)

    2017-01-15

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether {sup 18}F-fluorodeoxyglucose positron emission tomography - computed tomography ({sup 18}F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  7. Estimated cumulative radiation dose received by diagnostic imaging during staging and treatment of operable Ewing sarcoma 2005-2012

    International Nuclear Information System (INIS)

    Johnsen, Boel; Fasmer, Kristine Eldevik; Boye, Kjetil; Rosendahl, Karen; Aukland, Stein Magnus; Trovik, Clement; Biermann, Martin

    2017-01-01

    Patients with Ewing sarcoma are subject to various diagnostic procedures that incur exposure to ionising radiation. To estimate the radiation doses received from all radiologic and nuclear imaging episodes during diagnosis and treatment, and to determine whether 18 F-fluorodeoxyglucose positron emission tomography - computed tomography ( 18 F-FDG PET-CT) is a major contributor of radiation. Twenty Ewing sarcoma patients diagnosed in Norway in 2005-2012 met the inclusion criteria (age <30 years, operable disease, uncomplicated chemotherapy and surgery, no metastasis or residual disease within a year of diagnosis). Radiation doses from all imaging during the first year were calculated for each patient. The mean estimated cumulative radiation dose for all patients was 34 mSv (range: 6-70), radiography accounting for 3 mSv (range: 0.2-12), CT for 13 mSv (range: 2-28) and nuclear medicine for 18 mSv (range: 2-47). For the patients examined with PET-CT, the mean estimated cumulative effective dose was 38 mSv, of which PET-CT accounted for 14 mSv (37%). There was large variation in number and type of examinations performed and also in estimated cumulative radiation dose. The mean radiation dose for patients examined with PET-CT was 23% higher than for patients not examined with PET-CT. (orig.)

  8. Relationship between mutation frequency of GPA locus and cumulative dose among medical diagnostic X-ray workers

    International Nuclear Information System (INIS)

    Wang Jixian; Yu Wenru; Li Benxiao; Fan Tiqiang; Li Zhen; Gao Zhiwei; Chen Zhenjun; Zhao Yongcheng

    2000-01-01

    Objective: To explore the feasibility of using GPA locus mutation assay as a bio-dosimeter for occupational exposure to ionizing radiation. Methods: An improved technique of GPA locus mutation assay was used in th study. The frequencies of mutant RBC in peripheral blood of 55 medical X-ray workers and 50 controls employed in different calendar-year periods were detected. The relationship between mutation frequencies (MFs) and period of entry, working years and cumulative doses were analyzed. Results: The MFs were significantly elevated among X-ray workers employed before 1970. This finding is similar to the result of cancer epidemiological study among medical X-ray workers , in which the cancer risk was significantly increased only X-ray workers employed before 1970. The MFs of GPA increased with increasing cumulative dose. The dose-effect relationship of Nφ MF with cumulative dose was closer than that of NN MF. Conclusion: There are many problems to be solved for using GPA MF assay as a bio-dosimeter such as individual variation, specificity and calibration curve of dose-effect relationship

  9. Applicability of the tissue stem cell turnover concept on the validity of cumulative dose based radiation risk evaluation

    International Nuclear Information System (INIS)

    Otsuka, Kensuke; Hamada, Nobuyuki; Iwasaki, Toshiyasu; Yoshida, Kazuo

    2011-01-01

    The radiation protection system adopts the linear no-threshold model to achieve proper radiation protection for considering cancer risks resulting from radiation exposure. This model uses cumulative dose to a tissue for risk evaluation in which cumulative dose is related to the amount of DNA damage and consequential induction of gene mutation. In this concept, gene mutation accumulates in tissue stem cells, the putative target of carcinogenesis, with total dose given to the tissue. Unlike high-dose-rate exposure, epidemiological studies in high radiation background areas, such as Kerala in India, revealed that cancer risks is not elevated by the dose to the inhabitants, suggesting that there exists some mechanisms to eliminate the damage/mutation in the exposed tissue under extremely low-dose-rate exposure situations. In this report, the dynamics of tissue stem cell turnover is evaluated as a possible mechanism under extremely low-dose-rate exposure situations. To this end, we reviewed recent literatures studying tissue stem cell turnover, and found that great advances in stem cell research have made it possible to trace a fate of stem cells in tissues. Furthermore, turnover of tissue stem cells is found to occur after irradiation, due to competition of stem cells within tissues. This raises a possibility that radiation effects may not accumulate in a tissue depending on the dose-rate and duration of exposure period. (author)

  10. SU-E-J-106: The Use of Deformable Image Registration with Cone-Beam CT for a Better Evaluation of Cumulative Dose to Organs

    Energy Technology Data Exchange (ETDEWEB)

    Fillion, O; Gingras, L; Archambault, L [Universite Laval, Quebec, Quebec (Canada); Centre de recherche du CHU de Quebec, Quebec, Quebec (Canada); Centre de recherche sur le cancer, Quebec, Quebec (Canada)

    2015-06-15

    Purpose: The knowledge of dose accumulation in the patient tissues in radiotherapy helps in determining the treatment outcomes. This project aims at providing a workflow to map cumulative doses that takes into account interfraction organ motion without the need for manual re-contouring. Methods: Five prostate cancer patients were studied. Each patient had a planning CT (pCT) and 5 to 13 CBCT scans. On each series, a physician contoured the prostate, rectum, bladder, seminal vesicles and the intestine. First, a deformable image registration (DIR) of the pCTs onto the daily CBCTs yielded registered CTs (rCT) . This rCT combined the accurate CT numbers of the pCT with the daily anatomy of the CBCT. Second, the original plans (220 cGy per fraction for 25 fractions) were copied on the rCT for dose re-calculation. Third, the DIR software Elastix was used to find the inverse transform from the rCT to the pCT. This transformation was then applied to the rCT dose grid to map the dose voxels back to their pCT location. Finally, the sum of these deformed dose grids for each patient was applied on the pCT to calculate the actual dose delivered to organs. Results: The discrepancy between the planned D98 and D2 and these indices re-calculated on the rCT, are, on average, of −1 ± 1 cGy and 1 ± 2 cGy per fraction, respectively. For fractions with large anatomical motion, the D98 discrepancy on the re-calculated dose grid mapped onto the pCT can raise to −17 ± 4 cGy. The obtained cumulative dose distributions illustrate the same behavior. Conclusion: This approach allowed the evaluation of cumulative doses to organs with the help of uncontoured daily CBCT scans. With this workflow, the easy evaluation of doses delivered for EBRT treatments could ultimately lead to a better follow-up of prostate cancer patients.

  11. SU-E-J-106: The Use of Deformable Image Registration with Cone-Beam CT for a Better Evaluation of Cumulative Dose to Organs

    International Nuclear Information System (INIS)

    Fillion, O; Gingras, L; Archambault, L

    2015-01-01

    Purpose: The knowledge of dose accumulation in the patient tissues in radiotherapy helps in determining the treatment outcomes. This project aims at providing a workflow to map cumulative doses that takes into account interfraction organ motion without the need for manual re-contouring. Methods: Five prostate cancer patients were studied. Each patient had a planning CT (pCT) and 5 to 13 CBCT scans. On each series, a physician contoured the prostate, rectum, bladder, seminal vesicles and the intestine. First, a deformable image registration (DIR) of the pCTs onto the daily CBCTs yielded registered CTs (rCT) . This rCT combined the accurate CT numbers of the pCT with the daily anatomy of the CBCT. Second, the original plans (220 cGy per fraction for 25 fractions) were copied on the rCT for dose re-calculation. Third, the DIR software Elastix was used to find the inverse transform from the rCT to the pCT. This transformation was then applied to the rCT dose grid to map the dose voxels back to their pCT location. Finally, the sum of these deformed dose grids for each patient was applied on the pCT to calculate the actual dose delivered to organs. Results: The discrepancy between the planned D98 and D2 and these indices re-calculated on the rCT, are, on average, of −1 ± 1 cGy and 1 ± 2 cGy per fraction, respectively. For fractions with large anatomical motion, the D98 discrepancy on the re-calculated dose grid mapped onto the pCT can raise to −17 ± 4 cGy. The obtained cumulative dose distributions illustrate the same behavior. Conclusion: This approach allowed the evaluation of cumulative doses to organs with the help of uncontoured daily CBCT scans. With this workflow, the easy evaluation of doses delivered for EBRT treatments could ultimately lead to a better follow-up of prostate cancer patients

  12. The dose-response relationship between cumulative lifting load and lumbar disk degeneration based on magnetic resonance imaging findings.

    Science.gov (United States)

    Hung, Yu-Ju; Shih, Tiffany T-F; Chen, Bang-Bin; Hwang, Yaw-Huei; Ma, Li-Ping; Huang, Wen-Chuan; Liou, Saou-Hsing; Ho, Ing-Kang; Guo, Yue L

    2014-11-01

    Lumbar disk degeneration (LDD) has been related to heavy physical loading. However, the quantification of the exposure has been controversial, and the dose-response relationship with the LDD has not been established. The purpose of this study was to investigate the dose-response relationship between lifetime cumulative lifting load and LDD. This was a cross-sectional study. Every participant received assessments with a questionnaire, magnetic resonance imaging (MRI) of the lumbar spine, and estimation of lumbar disk compression load. The MRI assessments included assessment of disk dehydration, annulus tear, disk height narrowing, bulging, protrusion, extrusion, sequestration, degenerative and spondylolytic spondylolisthesis, foramina narrowing, and nerve root compression on each lumbar disk level. The compression load was predicted using a biomechanical software system. A total of 553 participants were recruited in this study and categorized into tertiles by cumulative lifting load (ie, lifting load. The best dose-response relationships were found at the L5-S1 disk level, in which high cumulative lifting load was associated with elevated odds ratios of 2.5 (95% confidence interval [95% CI]=1.5, 4.1) for dehydration and 4.1 (95% CI=1.9, 10.1) for disk height narrowing compared with low lifting load. Participants exposed to intermediate lifting load had an increased odds ratio of 2.1 (95% CI=1.3, 3.3) for bulging compared with low lifting load. The tests for trend were significant. There is no "gold standard" assessment tool for measuring the lumbar compression load. The results suggest a dose-response relationship between cumulative lifting load and LDD. © 2014 American Physical Therapy Association.

  13. In vivo measurements of lead-210 for assessing cumulative radon exposure in uranium miners

    Energy Technology Data Exchange (ETDEWEB)

    Guilmette, R.A.; Laurer, G.R. [New York Univ. Inst. of Environmental Medicine, Tuxedo, NY (United States); Lambert, W.E.; Gilliland, F.D. [Univ. of New Mexico, Albuquerque, NM (United States)] [and others

    1995-12-01

    It has long been recognized that a major contributor to the uncertainty in risk analysis of lung cancer in uranium and other hard rock miners is the estimation of total radon progeny exposure of individual miners under study. These uncertainties arise from the fact that only a limited number of measurements of airborne {sup 222}Rn progeny concentrations were made in the mines during the times that the miners were being exposed, and that dosimeters capable of integrating the Rn progeny exposures of the miners did not exist. Historically, the cumulative exposures for individual uranium and other hard rock miners have been calculated by combining the employee`s work history, which may or may not have included time spent at different jobs within the mines and at different locations within the mines, with whatever periodic measurements of Rn and Rn progeny were available. The amount and quality of the measurement data varied enormously from mine to mine and from population to population. Because the quality of the exposure data collected during the period of active mining in the United STates cannot now be altered substantially, significant improvement in individual miner exposure estimates is only likely to be achieved if a new cumulative exposure metric is developed and implemented. The decay chain of Rn includes the production of {sup 210}Pb, which can accumulate in the skeleton in amounts proportional to the intake of Rn progeny. We hypothesize that the in vivo measurement of {sup 210}Pb in the skulls of miners will provide such a metric. In summary, the primary purpose of this pilot study to demonstrate the feasibility of measuring {sup 210}Pb in the heads of former uranium miners has been accomplished.

  14. In vivo measurements of lead-210 for assessing cumulative radon exposure in uranium miners

    International Nuclear Information System (INIS)

    Guilmette, R.A.; Laurer, G.R.; Lambert, W.E.; Gilliland, F.D.

    1995-01-01

    It has long been recognized that a major contributor to the uncertainty in risk analysis of lung cancer in uranium and other hard rock miners is the estimation of total radon progeny exposure of individual miners under study. These uncertainties arise from the fact that only a limited number of measurements of airborne 222 Rn progeny concentrations were made in the mines during the times that the miners were being exposed, and that dosimeters capable of integrating the Rn progeny exposures of the miners did not exist. Historically, the cumulative exposures for individual uranium and other hard rock miners have been calculated by combining the employee's work history, which may or may not have included time spent at different jobs within the mines and at different locations within the mines, with whatever periodic measurements of Rn and Rn progeny were available. The amount and quality of the measurement data varied enormously from mine to mine and from population to population. Because the quality of the exposure data collected during the period of active mining in the United STates cannot now be altered substantially, significant improvement in individual miner exposure estimates is only likely to be achieved if a new cumulative exposure metric is developed and implemented. The decay chain of Rn includes the production of 210 Pb, which can accumulate in the skeleton in amounts proportional to the intake of Rn progeny. We hypothesize that the in vivo measurement of 210 Pb in the skulls of miners will provide such a metric. In summary, the primary purpose of this pilot study to demonstrate the feasibility of measuring 210 Pb in the heads of former uranium miners has been accomplished

  15. Relationship of cumulative low-level dose of ionizing radiation on human eye lens and occurrence of cataract

    International Nuclear Information System (INIS)

    Deolalikar, Raghavendra

    2015-01-01

    International Commission on Radiological Protection (ICRP), issued a statement on Tissue Reaction, lowering the equivalent dose limit for eye lens for occupational exposure to 20 mSv per year. With a view to determine presence of any relationship between the cumulative low-level occupational radiation dose to the eye lens and occurrence of cataract, departmental records of the annual medical examination of employees of Narora Atomic Power Plant were examined along with the NAPS eye camps and surgical records of the employees. Analysis of the data showed no demonstrable definite relationship between the two. The analysis of the data and the observations are discussed in this paper. (author)

  16. Quantitative assessment of cumulative damage from repetitive exposures to suberythemogenic doses of UVA in human skin

    International Nuclear Information System (INIS)

    Lavker, R.M.; Kaidbey, K.H.

    1995-01-01

    Daily exposures to relatively small suberythemogenic fluences of UVA (50-200 kJ/m 2 ) for 8 days resulted in cumulative morphological skin alterations indicative of early tissue injury. Histologically, irradiated skin revealed epidermal hyperplasia, inflammation and deposition of lysozyme along the dermal elastic fiber network. Sunburn cells were also present within the epidermis. These changes were quantified by image analysis and were found to be related to the cumulative UVA fluence. A long UVA waveband (UVAI, 340-400 nm) was as effective as a broad UVA band (320-400 nm), suggesting that these changes are induced by longer UVA wavelengths. (author)

  17. A study of the relationship between peak skin dose and cumulative air kerma in interventional neuroradiology and cardiology

    International Nuclear Information System (INIS)

    Neil, S; Padgham, C; Martin, C J

    2010-01-01

    A study of peak skin doses (PSDs) during neuroradiology and cardiology interventional procedures has been carried out using Gafchromic XR-RV2 film. Use of mosaics made from squares held in cling film has allowed doses to the head to be mapped successfully. The displayed cumulative air kerma (CAK) has been calibrated in terms of cumulative entrance surface dose (CESD) and results indicate that this can provide a reliable indicator of the PSD in neuroradiology. Results linking PSD to CESD for interventional cardiology were variable, but CAK is still considered to provide the best option for use as an indicator of potential radiation-induced effects. A CESD exceeding 3 Gy is considered a suitable action level for triggering follow-up of patients in neuroradiology and cardiology for possible skin effects. Application of dose action levels defined in this way would affect 8% of neurological embolisation procedures and 5% of cardiology ablation and multiple stent procedures at the hospitals where the investigations were carried out. A close relationship was observed between CESD and dose-area product (DAP) for particular types of procedure, and DAPs of 200-300 Gy cm 2 could be used as trigger levels where CAK readings were not available. The DAP value would depend on the mean field size and would need to be determined for each application.

  18. Cumulative effective dose and cancer risk for pediatric population in repetitive full spine follow-up imaging: How micro dose is the EOS microdose protocol?

    Science.gov (United States)

    Law, Martin; Ma, Wang-Kei; Lau, Damian; Cheung, Kenneth; Ip, Janice; Yip, Lawrance; Lam, Wendy

    2018-04-01

    To evaluate and to obtain analytic formulation for the calculation of the effective dose and associated cancer risk using the EOS microdose protocol for scoliotic pediatric patients undergoing full spine imaging at different age of exposure; to demonstrate the microdose protocol capable of delivering lesser radiation dose and hence of further reducing cancer risk induction when compared with the EOS low dose protocol; to obtain cumulative effective dose and cancer risk for both genders scoliotic pediatrics of US and Hong Kong population using the microdose protocol. Organ absorbed doses of full spine exposed scoliotic pediatric patients have been simulated with the use of EOS microdose protocol imaging parameters input to the Monte Carlo software PCXMC. Gender and age specific effective dose has been calculated with the simulated organ absorbed dose using the ICRP-103 approach. The associated radiation induced cancer risk, expressed as lifetime attributable risk (LAR), has been estimated according to the method introduced in the Biological Effects of Ionizing Radiation VII report. Values of LAR have been estimated for scoliotic patients exposed repetitively during their follow up period at different age for US and Hong Kong population. The effective doses of full spine imaging with simultaneous posteroanterior and lateral projection for patients exposed at the age between 5 and 18 years using the EOS microdose protocol have been calculated within the range of 2.54-14.75 μSv. The corresponding LAR for US and Hong Kong population was ranged between 0.04 × 10 -6 and 0.84 × 10 -6 . Cumulative effective dose and cancer risk during follow-up period can be estimated using the results and are of information to patients and their parents. With the use of computer simulation and analytic formulation, we obtained the cumulative effective dose and cancer risk at any age of exposure for pediatric patients of US and Hong Kong population undergoing repetitive

  19. Synergistic effect of cumulative corticosteroid dose and immunosuppressants on avascular necrosis in patients with systemic lupus erythematosus.

    Science.gov (United States)

    Kwon, H H; Bang, S Y; Won, S; Park, Y; Yi, J H; Joo, Y B; Lee, H S; Bae, S C

    2018-01-01

    Objectives Avascular necrosis (AVN) is one of the most common causes of organ damage in patients with systemic lupus erythematosus (SLE) and often causes serious physical disability. The aims of this study were to investigate clinical risk factors associated with symptomatic AVN and to analyze their synergistic effects in a large SLE cohort in Korea. Methods Patients with SLE were enrolled and followed from 1998 to 2014 in the Hanyang BAE Lupus cohort, and damage was measured annually according to the Systemic Lupus International Collaborating Clinics/American College of Rheumatology Damage Index (SDI). AVN was confirmed by imaging study if patients had symptoms. To determine risk factors for AVN, clinical, laboratory and therapeutic variables were analyzed by logistic regression. Relative excess risk due to interaction (RERI), attributable proportion (AP), and synergy index (S) were calculated to measure interactions between significant variables. Results Among 1219 SLE patients, symptomatic AVN was the most common type of musculoskeletal damage (10.8%, n = 132). SLE patients with AVN showed an earlier onset age, demonstrated AVN more commonly in conjunction with certain other clinical manifestations such as renal and neuropsychiatric disorders, and received significantly higher total cumulative corticosteroid dose and immunosuppressive agents than did patients without AVN. However, in multivariable analysis, only two variables including use of a cumulative corticosteroid dose greater than 20 g (odds ratio (OR) 3.62, p = 0.015) and use of immunosuppressants including cyclophosphamide or mycophenolate mofetil (OR 4.51, p AVN. Patients with cumulative corticosteroid dose > 20 g and immunosuppressant use had a 15.44-fold increased risk for AVN, compared with patients without these risk factors ( p AVN in our Korean lupus cohort. Conclusions An individual risk assessment for AVN development should be made prior to and during treatment for SLE

  20. Estimated cumulative radiation dose from PET/CT in children with malignancies: a 5-year retrospective review

    International Nuclear Information System (INIS)

    Chawla, Soni C.; Federman, Noah; Zhang, Di; Nagata, Kristen; Nuthakki, Soujanya; McNitt-Gray, Michael; Boechat, M.I.

    2010-01-01

    The increasing use of serial PET/CT scans in the management of pediatric malignancies raises the important consideration of radiation exposure in children. To estimate the cumulative radiation dose from PET/CT studies to children with malignancy and to compare with the data in literature. Two hundred forty-eight clinical PET/CT studies performed on 78 patients (50 boys/28 girls, 1.3 to 18 years old from December 2002 to October 2007) were retrospectively reviewed under IRB approval. The whole-body effective dose (ED) estimates for each child were obtained by estimating the effective dose from each PET/CT exam performed using the ImPACT Patient Dosimetry Calculator for CT and OLINDA for PET. The average number of PET/CT studies was 3.2 per child (range: 1 to 14 studies). The average ED of an individual CT study was 20.3 mSv (range: 2.7 to 54.2), of PET study was 4.6 mSv (range: 0.4 to 7.7) and of PET/CT study was 24.8 mSv (range: 6.2 to 60.7). The average cumulative radiation dose per patient from CT studies was 64.4 mSv (range: 2.7 to 326), from PET studies was 14.5 mSv (range: 2.8 to 73) and from PET/CT studies was 78.9 mSv (range: 6.2 to 399). The radiation exposure from serial PET/CT studies performed in pediatric malignancies was considerable; however, lower doses can be used for both PET and CT studies. The ALARA principle must be applied without sacrificing diagnostic information. (orig.)

  1. Dose estimates in a loss of lead shielding truck accident.

    Energy Technology Data Exchange (ETDEWEB)

    Dennis, Matthew L.; Osborn, Douglas M.; Weiner, Ruth F.; Heames, Terence John (Alion Science & Technology Albuquerque, NM)

    2009-08-01

    The radiological transportation risk & consequence program, RADTRAN, has recently added an updated loss of lead shielding (LOS) model to it most recent version, RADTRAN 6.0. The LOS model was used to determine dose estimates to first-responders during a spent nuclear fuel transportation accident. Results varied according to the following: type of accident scenario, percent of lead slump, distance to shipment, and time spent in the area. This document presents a method of creating dose estimates for first-responders using RADTRAN with potential accident scenarios. This may be of particular interest in the event of high speed accidents or fires involving cask punctures.

  2. Cumulative dose 60Co gamma irradiation effects on AlGaN/GaN Schottky diodes and its area dependence

    Science.gov (United States)

    Sharma, Chandan; Laishram, Robert; Rawal, Dipendra Singh; Vinayak, Seema; Singh, Rajendra

    2018-04-01

    Cumulative dose gamma radiation effects on current-voltage characteristics of GaN Schottky diodes have been investigated. The different area diodes have been fabricated on AlGaN/GaN high electron mobility transistor (HEMT) epi-layer structure grown over SiC substrate and irradiated with a dose up to the order of 104 Gray (Gy). Post irradiation characterization shows a shift in the turn-on voltage and improvement in reverse leakage current. Other calculated parameters include Schottky barrier height, ideality factor and reverse saturation current. Schottky barrier height has been decreased whereas reverse saturation current shows an increase in the value post irradiation with improvement in the ideality factor. Transfer length measurement (TLM) characterization shows an improvement in the contact resistance. Finally, diodes with larger area have more variation in the calculated parameters due to the induced local heating effect.

  3. Measurement of radiocesium concentration in trees using cumulative gamma radiation dose rate detection systems - A simple presumption for radiocesium concentration in living woods using glass-badge based gamma radiation dose rate detection system

    Energy Technology Data Exchange (ETDEWEB)

    Yoshihara, T.; Hashida, S.N. [Plant Molecular Biology, Laboratory of Environmental Science, Central Research Institute of Electric Power Industry (CRIEPI), 1646 Abiko, Chiba 270-1194 (Japan); Kawachi, N.; Suzui, N.; Yin, Y.G.; Fujimaki, S. [Radiotracer Imaging Gr., Quantum Beam Science Center, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan); Nagao, Y.; Yamaguchi, M. [Takasaki Advanced Radiation Research Institute, Japan Atomic Energy Agency (JAEA), 1233 Watanuki, Takasaki, Gunma 370-1292 (Japan)

    2014-07-01

    Radiocesium from the severe accident at the Fukushima Dai-ichi Nuclear Power Plant on 11 March 2011 contaminates large areas. After this, a doubt for forest products, especially of mushroom, is indelible at the areas. Pruned woody parts and litters are containing a considerable amount of radiocesium, and generates a problem at incineration and composting. These mean that more attentive survey for each subject is expected; however, the present survey system is highly laborious/expensive and/or non-effective for this purpose. On the other hand, we can see a glass-badge based gamma radiation dose rate detection system. This system always utilized to detect a personal cumulative radiation dose, and thus, it is not suitable to separate a radiation from a specific object. However, if we can separate a radiation from a specific object and relate it with the own radiocesium concentration, it would enable us to presume the specific concentration with just an easy monitoring but without a destruction of the target nature and a complicated process including sampling, pre-treatment, and detection. Here, we present the concept of the measurement and results of the trials. First, we set glass-badges (type FS, Chiyoda Technol Corp., Japan) on a part of bough (approximately 10 cm in diameter) of Japanese flowering cherry trees (Prunus x yedoensis cv. Somei-Yoshino) with four different settings: A, a direct setting without any shield; B, a setting with an aluminum shield between bough and the glass-badge; C, a setting with a lead shield between bough and the glass-badge; D, a setting with a lead shield covering the glass-badge to shut the radiation from the surrounding but from bough. The deduction between the amount of each setting should separate a specific radiation of the bough from unlimited radiation from the surrounding. Even if the hourly dose rate is not enough to count the difference, a moderate cumulative dose would clear the difference. In fact, results demonstrated a

  4. Risk of therapy-related leukaemia and preleukaemia after Hodgkin's disease. Relation to age, cumulative dose of alkylating agents, and time from chemotherapy

    DEFF Research Database (Denmark)

    Pedersen-Bjergaard, J.; Specht, L.; Larsen, S.O.

    1987-01-01

    391 patients treated intensively for Hodgkin's disease were followed for up to 15 years to evaluate the risk of therapy-related acute non-lymphocytic leukaemia (t-ANLL) and preleukaemia. Only two independent factors, patient age and cumulative dose of alkylating agents, were related to the risk...... of t-ANLL. The hazard rate of t-ANLL was roughly proportional to the square of patient age and to the total cumulative dose of alkylating agents. In 320 patients treated with alkylating agents the cumulative risk of t-ANLL increased steadily from 1 year after the start of treatment and reached 13.......0% (SE 3.0) at 10 years after which time there were no further cases. Calculated from cessation of therapy with alkylating agents, however, the cumulative risk curve increased steeply during the first 1-2 years then gradually levelled out and no new cases were observed beyond 7 years. With a 15-year...

  5. Clinical significance of cumulative biological effective dose and overall treatment time in the treatment of carcinoma cervix

    Directory of Open Access Journals (Sweden)

    Mandal Abhijit

    2007-01-01

    Full Text Available The purpose of this retrospective study is to report the radiotherapy treatment response of, and complications in, patients with cervical cancer on the basis of cumulative biologic effective dose (BED and overall treatment time (OTT. Sixty-four (stage II - 35/64; stage III - 29/64 patients of cervical cancer were treated with combination of external beam radiotherapy (EBRT and low dose rate intracavitary brachytherapy (ICBT. The cumulative BED was calculated at Point A (BED 10 ; and bladder, rectal reference points (BED 2.5 using the linear-quadratic BED equations. The local control (LC rate and 5-year disease-free survival (DFS rate in patients of stage II were comparable for BED 10 < 84.5 and BED 10 > 84.5 but were much higher for BED 10 > 84.5 than BED 10 < 84.5 ( P < 0.01 in stage III patients. In the stage II patients, The LC rate and 5-year DFS rate were comparable for OTT < 50 days and for OTT> 50 days but were much higher in stage III patients with OTT < 50 than OTT> 50 days ( P < 0.001. It was also observed that patients who received BED 2.5 < 105 had lesser rectal ( P < 0.001 and bladder complications than BED 2.5 > 105. Higher rectal complication-free survival (CFS R rate, bladder complication-free survival (CFS B rate and all-type late complication-free survival rate were observed in patients who received BED 2.5 < 105 than BED 2.5 > 105. A balanced, optimal and justified radiotherapy treatment schedule to deliver higher BED 10 (>84.5 and lower BED 2.5 (< 105 in lesser OTT (< 50 days is essential in carcinoma cervix to expect a better treatment outcome in all respects.

  6. Measurement of soil contamination by radionuclides due to the Fukushima Dai-ichi Nuclear Power Plant accident and associated estimated cumulative external dose estimation

    International Nuclear Information System (INIS)

    Endo, S.; Kimura, S.; Takatsuji, T.; Nanasawa, K.; Imanaka, T.; Shizuma, K.

    2012-01-01

    Soil sampling was carried out at an early stage of the Fukushima Dai-ichi Nuclear Power Plant (FDNPP) accident. Samples were taken from areas around FDNPP, at four locations northwest of FDNPP, at four schools and in four cities, including Fukushima City. Radioactive contaminants in soil samples were identified and measured by using a Ge detector and included 129m Te, 129 Te, 131 I, 132 Te, 132 I, 134 Cs, 136 Cs, 137 Cs, 140 Ba and 140 La. The highest soil depositions were measured to the northwest of FDNPP. From this soil deposition data, variations in dose rates over time and the cumulative external doses at the locations for 3 months and 1 y after deposition were estimated. At locations northwest of FDNPP, the external dose rate at 3 months after deposition was 4.8–98 μSv/h and the cumulative dose for 1 y was 51 to 1.0 × 10 3 mSv; the highest values were at Futaba Yamada. At the four schools, which were used as evacuation shelters, and in the four urban cities, the external dose rate at 3 months after deposition ranged from 0.03 to 3.8 μSv/h and the cumulative doses for 1 y ranged from 3 to 40 mSv. The cumulative dose at Fukushima Niihama Park was estimated as the highest in the four cities. The estimated external dose rates and cumulative doses show that careful countermeasures and remediation will be needed as a result of the accident, and detailed measurements of radionuclide deposition densities in soil will be important input data to conduct these activities.

  7. Fitness costs of increased cataract frequency and cumulative radiation dose in natural mammalian populations from Chernobyl.

    Science.gov (United States)

    Lehmann, Philipp; Boratyński, Zbyszek; Mappes, Tapio; Mousseau, Timothy A; Møller, Anders P

    2016-01-27

    A cataract is a clouding of the lens that reduces light transmission to the retina, and it decreases the visual acuity of the bearer. The prevalence of cataracts in natural populations of mammals, and their potential ecological significance, is poorly known. Cataracts have been reported to arise from high levels of oxidative stress and a major cause of oxidative stress is ionizing radiation. We investigated whether elevated frequencies of cataracts are found in eyes of bank voles Myodes glareolus collected from natural populations in areas with varying levels of background radiation in Chernobyl. We found high frequencies of cataracts in voles collected from different areas in Chernobyl. The frequency of cataracts was positively correlated with age, and in females also with the accumulated radiation dose. Furthermore, the number of offspring in female voles was negatively correlated with cataract severity. The results suggest that cataracts primarily develop as a function of ionizing background radiation, most likely as a plastic response to high levels of oxidative stress. It is therefore possible that the elevated levels of background radiation in Chernobyl affect the ecology and fitness of local mammals both directly through, for instance, reduced fertility and indirectly, through increased cataractogenesis.

  8. Cumulative inhibitory effect of low-dose aspirin on vascular prostacyclin and platelet thromboxane production in patients with atherosclerosis.

    Science.gov (United States)

    Weksler, B B; Tack-Goldman, K; Subramanian, V A; Gay, W A

    1985-02-01

    The relationship between the antithrombotic and antiplatelet effects of aspirin is complex, since aspirin influences other systems that protect against thrombosis as well as inhibiting platelet function. We investigated possible cumulative effects of low-dose aspirin on vascular production of prostacyclin in patients with documented atherosclerotic cardiovascular disease. Candidates for coronary artery vein graft bypass ingested 20 mg of aspirin daily during the week before surgery, and platelet aggregation, platelet formation of thromboxane A2 (TXA2), aortic and saphenous vein production of prostacyclin (PGI2), and hemostatic status were measured at the time of the bypass surgery. Low-dose aspirin markedly inhibited platelet aggregation responses and reduced TXA2 generation by greater than 90%, effects similar to those observed with much higher doses of aspirin. Both aortic and saphenous vein production of PGI2 were inhibited by 50% compared with PGI2 produced by vascular tissues of control subjects who received no aspirin preoperatively (51 +/- 10 pg 6-keto-PGF1 alpha/mg aortic wet weight [mean +/- SEM] in aspirin-treated subjects vs 130 +/- 16 pg/mg in control subjects, and 71 +/- 8 pg/mg saphenous vein wet weight vs 131 +/- 17 pg/mg). Blood loss at surgery was not significantly increased by preoperative low-dose aspirin as measured by chest tube drainage (754 +/- 229 ml in aspirin-treated subjects vs 645 +/- 271 ml in control subjects), hematocrit nadir (31.2 +/- 1.9% vs 31.8 +/- 1.7%), or transfusions (2.2 +/- 1.3 units of red blood cells vs 2.2 +/- 1.7 units).(ABSTRACT TRUNCATED AT 250 WORDS)

  9. Dicer1 depletion in male germ cells leads to infertility due to cumulative meiotic and spermiogenic defects.

    Directory of Open Access Journals (Sweden)

    Yannick Romero

    Full Text Available BACKGROUND: Spermatogenesis is a complex biological process that requires a highly specialized control of gene expression. In the past decade, small non-coding RNAs have emerged as critical regulators of gene expression both at the transcriptional and post-transcriptional level. DICER1, an RNAse III endonuclease, is essential for the biogenesis of several classes of small RNAs, including microRNAs (miRNAs and endogenous small interfering RNAs (endo-siRNAs, but is also critical for the degradation of toxic transposable elements. In this study, we investigated to which extent DICER1 is required for germ cell development and the progress of spermatogenesis in mice. PRINCIPAL FINDINGS: We show that the selective ablation of Dicer1 at the early onset of male germ cell development leads to infertility, due to multiple cumulative defects at the meiotic and post-meiotic stages culminating with the absence of functional spermatozoa. Alterations were observed in the first spermatogenic wave and include delayed progression of spermatocytes to prophase I and increased apoptosis, resulting in a reduced number of round spermatids. The transition from round to mature spermatozoa was also severely affected, since the few spermatozoa formed in mutant animals were immobile and misshapen, exhibiting morphological defects of the head and flagellum. We also found evidence that the expression of transposable elements of the SINE family is up-regulated in Dicer1-depleted spermatocytes. CONCLUSIONS/SIGNIFICANCE: Our findings indicate that DICER1 is dispensable for spermatogonial stem cell renewal and mitotic proliferation, but is required for germ cell differentiation through the meiotic and haploid phases of spermatogenesis.

  10. Physiological and immunological changes following exposure to low versus high-dose ionizing irradiation; comparative analysis with dose rate and cumulative dose

    International Nuclear Information System (INIS)

    Heesun, Kim; Heewon, Jang; Soungyeon, Song; Shinhye, Oh; Cukcheul, Shin; Meeseon, Jeong; Chasoon, Kim; Kwnaghee, Yang; Seonyoung, Nam; Jiyoung, Kim; Youngwoo, Jin; Changyoung, Cha

    2008-01-01

    Full text: While high-dose of ionizing radiation is generally harmful and causes damage to living organisms some reports suggest low-dose of radiation may not be as damaging as previously thought. Despite increasing evidence regarding the protective effect of low-dose radiation, no studies have directly compared the exact dose-response pattern by high- and low-dose of radiation exposed at high-and low-dose rate. This study aims to explore the cellular and molecular changes in mice exposed to low- and high-dose of radiation exposed at low- and high-dose rate. When C57BL/6 mice (Female, 6 weeks) were exposed at high-dose rate, 0.8 Gy/min, no significant change on the level of WBC, RBC, or platelets was observed up to total dose of 0.5 Gy. However, 2 Gy of radiation caused dramatic reduction in the level of white blood cells (WBC) and platelets. This reduction was accompanied by increased DNA damage in hematopoietic environments. The reduction of WBC was mainly due to the reduction in the number of CD4+ T cells and CD19+ B cells. CD8+ T cells and NK cells appeared to be relatively resistant to high-dose of radiation. This change was also accompanied by the reduction of T- and B- progenitor cells in the bone marrow. In contrast, no significant changes of the number of CD4+ T, CD8+ T, NK, and B cells were observed in the spleen of mice exposed at low-dose-rate (0.7 m Gy/h or 3.95 mGy/h) for up to 2 Gy, suggesting that low-dose radiation does not alter cellular distribution in the spleen. Nevertheless, mice exposed to low-dose radiation exhibited elevation of VEGF, MCP-1, IL-4, Leptin, IL-3, and Tpo in the peripheral blood and slight increases in MIP-2, RANTES, and IL-2 in the spleen. This suggests that chronic γ-radiation can stimulate immune function without causing damage to the immune components of the body. Taken together, these data indicate hormesis of low-dose radiation, which could be attributed to the stimulation of immune function. Dose rate rather than total

  11. Determination of skin dose reduction by lead equivalent gloves

    International Nuclear Information System (INIS)

    Norriza Mohd Isa; Abd Aziz Mhd Ramli

    2006-01-01

    Radiation protective gloves are always used in medical facilities to protect radiation workers from unnecessary radiation exposure. A study on radiation protection gloves which are produced by local company had been performed by the Medical Physics Group, MINT. The gloves were made of lead equivalent material, as the attenuating element. The gloves were evaluated in term of the percentage of skin dose reduction by using a newly developed procedure and facilities in MINT. Attenuation measurements of the gloves had been carried out using direct beams and scattered radiations of different qualities. TLD rings were fitted on finger phantom; and water phantom were used in the measurement. The result were obtained and analysed based on data supplied by manufacturer. (Author)

  12. Estimation of organ cumulated activities and absorbed doses on intakes of several 11C labelled radiopharmaceuticals from external measurement with thermoluminescent dosimeters.

    Science.gov (United States)

    Nakamura, T; Hayashi, Y; Watabe, H; Matsumoto, M; Horikawa, T; Fujiwara, T; Ito, M; Yanai, K

    1998-02-01

    We have developed a method for obtaining the cumulated activities in organs from radionuclides, which are injected into the patient in nuclear medicine procedures, by external exposure measurement with thermoluminescent dosimeters (TLDs) which are attached to the patient's body surface close to source organs to obtain information on body-surface doses. As the surface dose is connected to the cumulated activities in source organs through radiation transmission in the human body which can be estimated with the aid of a mathematical phantom, the organ cumulated activities can be obtained by the inverse transform method. The accuracy of this method was investigated by using a water phantom in which several gamma-ray volume sources of known activity were placed to simulate source organs. We then estimated by external measurements the organ cumulated activities and absorbed doses in subjects to whom the radiopharmaceuticals 11C-labelled Doxepin, 11C-labelled YM09151-2 and 11C-labelled Benzotropin were administered in clinical nuclear medicine procedures. The cumulated activities in the brain obtained with TLDs for Doxepin and YM09151-2 are 63.6 +/- 6.2 and 32.1 +/- 12.0 kBq h MBq-1 respectively, which are compared with the respective values of 33.3 +/- 9.9 and 23.9 +/- 6.2 kBq h MBq-1 with direct PET (positron emission tomography) measurements. The agreement between the two methods is within a factor of two. The effective doses of Doxepin, YM09151-2 and Benzotropin are determined as 6.92 x 10(-3), 7.08 x 10(-3) and 7.65 x 10(-3) mSv MBq-1 respectively with the TLD method. This method has great advantages, in that cumulated activities in several organs can be obtained easily with a single procedure, and the measurements of body surface doses are performed simultaneously with the nuclear medicine procedure, as TLDs are too small to interfere with other medical measurements.

  13. Estimation of organ cumulated activities and absorbed doses on intakes of several {sup 11}C labelled radiopharmaceuticals from external measurement with thermoluminescent dosimeters

    Energy Technology Data Exchange (ETDEWEB)

    Nakamura, Takashi; Hayashi, Yoshiharu; Watabe, Hiroshi; Matsumoto, Masaki; Horikawa, Tohru; Fujiwara, Takehiko; Ito, Masatoshi; Yanai, Kazuhiko [Cyclotron and Radioisotope Center, Tohoku University, Aoba, Aramaki, Sendai 980-77 (Japan)

    1998-02-01

    We have developed a method for obtaining the cumulated activities in organs from radionuclides, which are injected into the patient in nuclear medicine procedures, by external exposure measurement with thermoluminescent dosimeters (TLDs) which are attached to the patient's body surface close to source organs to obtain information on body-surface doses. As the surface dose is connected to the cumulated activities in source organs through radiation transmission in the human body which can be estimated with the aid of a mathematical phantom, the organ cumulated activities can be obtained by the inverse transform method. The accuracy of this method was investigated by using a water phantom in which several gamma-ray volume sources of known activity were placed to simulate source organs. We then estimated by external measurements the organ cumulated activities and absorbed doses in subjects to whom the radiopharmaceuticals {sup 11}C-labelled Doxepin, {sup 11}C-labelled YM09151-2 and {sup 11}C-labelled Benzotropin were administered in clinical nuclear medicine procedures. The cumulated activities in the brain obtained with TLDs for Doxepin and YM09151-2 are 63.6{+-}6.2 and 32.1{+-}12.0 kBq h MBq{sup -1} respectively, which are compared with the respective values of 33.3{+-}9.9 and 23.9{+-}6.2 kBq h MBq{sup -1} with direct PET (positron emission tomography) measurements. The agreement between the two methods is within a factor of two. The effective doses of Doxepin, YM09151-2 and Benzotropin are determined as 6.92x10{sup -3}, 7.08x10{sup -3} and 7.65x10{sup -3} mSv MBq{sup -1} respectively with the TLD method. This method has great advantages, in that cumulated activities in several organs can be obtained easily with a single procedure, and the measurements of body surface doses are performed simultaneously with the nuclear medicine procedure, as TLDs are too small to interfere with other medical measurements. (author)

  14. Effect of dose on lead retention and distribution in suckling and adult female mice

    International Nuclear Information System (INIS)

    Keller, C.A.; Doherty, R.A.

    1980-01-01

    Single doses of lead (trace to 445 mg/kg) were administered per os to suckling and adult mice. Both groups exhibited dose-independent lead retention when doses of 4 to 445 mg/kg were administered. However, developmental differences in the fraction of initial dose (FID) retained were evident for all doses administered. A much larger FID was retained in both age groups following administration of carrier-free 203 Pb. The results are consistent with a mechanism of gastrointestinal lead absorption comprising two or more processes. Developmental differences were also observed in organ lead concentration relative to whole body concentration for kidneys, skull and brain 6 days following lead administration. Lead retentions (relative to whole body retention) in brain and in bone were linearly related to dose of lead administered in both suckling and adult age groups. Though uptake of lead into brain and into femur was observed to be directly related to dose over a wide range, relative blood lead concentrations were not linearly correlated with dose administered. The relationships between lead concentrations of blood and organ(s) were also shown to be nonlinear relative to dose. However, blood lead concentration was found to be a reliable indicator of kidney and liver lead concentrations following an acute lead exposure

  15. Current and historical individual data about exposure of workers in the rayon industry to carbon disulfide and their validity in calculating the cumulative dose.

    Science.gov (United States)

    Göen, Thomas; Schramm, Axel; Baumeister, Thomas; Uter, Wolfgang; Drexler, Hans

    2014-08-01

    The objective of the study was to investigate how exposure to carbon disulfide (CS2) in a rayon-manufacturing plant has changed within two decades and whether it is possible to calculate valid data for the individual cumulative exposure. The data for CS2 concentration in air and biological exposure monitoring (2-thio-1,3-thiaxolidine-4-carboxylic acid (TTCA) in urine) from two cross-sectional studies, performed in 1992 (n = 362) and 2009 (n = 212) in a German rayon-manufacturing plant, were compared to data obtained from company-internal measurements between the studies. Using the data from the cross-sectional studies and company-internal data, cumulative external exposure and the cumulative internal exposure were calculated for each worker. External and internal CS2 exposure of the employees decreased from 1992 (medians 4.0 ppm and 1.63 mgTTCA/g creatinine) to 2009 (medians 2.5 ppm and 0.86 mg/g). However, company-internal CS2 data do not show a straight trend for this period. The annual medians of the company-internal measurement of external exposure to CS2 have varied between 2.7 and 8.4 ppm, in which median values exceeded 5 ppm generally since 2000. The annual medians for the company-internal biomonitoring assessment ranged between 1.2 and 2.8 mg/g creatinine. The cumulative CS2 exposure ranged from 8.5 to 869.5 ppm years for external exposure and between 1.30 and 176.2 mg/g creatinine years for the internal exposure. Significant correlations were found between the current air pollution and the internal exposure in 2009 but also between the cumulative external and internal CS2 exposure. Current exposure data, usually collected in cross-sectional studies, rarely allow a reliable statement on the cumulative dose, because of higher exposure in the past and of fluctuating courses of exposure. On the other hand, company-internal exposure data may be affected by non-representative measurement strategies. Some verification of the reliability of

  16. An assessment of cumulative external doses from Chernobyl fallout for a forested area in Russia using the optically stimulated luminescence from quartz inclusions in bricks

    DEFF Research Database (Denmark)

    Ramzaev, V.; Bøtter-Jensen, Lars; Thomsen, Kristina Jørkov

    2008-01-01

    . The area was significantly contaminated by Chernobyl fallout with initial (CS)-C-137 ground deposition level of similar to 1.1 MBq m(-2). The accumulated OSL doses in sections of the bricks varied from 141 to 207 mGy, of which between 76 and 146 mGy are attributable to Chernobyl fallout. Using the OSL...... depth-dose profiles obtained from the exposed bricks and the results from a gamma-ray-survey of the area, the Chernobyl-related cumulative gamma-ray dose for a point detector located in free air at a height of 1 m above the ground in the study area was estimated to be ca. 240 mGy for the time period...... starting on 27 April 1986 and ending on 31 July 2004. This result is in good agreement with the result of deterministic modelling of the cumulative gamma-ray dose in free air above undisturbed ground from the Chernobyl source in the Bryansk Region. Over the same time period, the external Chernobyl...

  17. Double dose: the cumulative effect of TV viewing at home and in preschool on children's activity patterns and weight status.

    Science.gov (United States)

    Taverno Ross, Sharon; Dowda, Marsha; Saunders, Ruth; Pate, Russell

    2013-05-01

    Little is known about how screen-based sedentary behavior at home and in preschool influences children's health and activity patterns. The current study examined the individual and cumulative influence of TV viewing at home and in preschool on children's physical activity (PA) and weight status. Children (n = 339) attending 16 preschools in South Carolina were grouped into high and low TV groups based on parent report of children's TV viewing at home and director report of TV use/rules in preschool. T-tests and mixed model ANOVAs examined differences in weight status and PA (min/hr) by high and low TV groups. Results revealed that children who were classified as High TV both at home and in pre- school had significantly lower levels of moderate-to-vigorous PA compared with their Low TV counterparts (8.3 (0.3) min/hr vs. 7.6 (0.2) min/hr, p TV groups at home or in preschool when examined individually. These findings demonstrate the importance of total environmental TV exposure on preschooler's PA. Longitudinal and observational research to assess preschoolers' cumulative screen-based sedentary behavior and its relationship with PA and weight status is needed.

  18. An investigation of dose changes for therapeutic kilovoltage x-ray beams with underlying lead shielding

    International Nuclear Information System (INIS)

    Hill, Robin; Healy, Brendan; Holloway, Lois; Baldock, Clive

    2007-01-01

    Kilovoltage x-ray beams are used to treat cancer on or close to the skin surface. Many clinical cases use high atomic number materials as shielding to reduce dose to underlying healthy tissues. In this work, we have investigated the effect on both the surface dose and depth doses in a water phantom with lead shielding at depth in the phantom. The EGSnrc Monte Carlo code was used to simulate the water phantom and to calculate the surface doses and depth doses using primary x-ray beam spectra derived from an analytical model. The x-ray beams were in the energy range of 75-135 kVp with field sizes of 2, 5 and 8 cm diameter. The lead sheet was located beneath the water surface at depths ranging from 0.5-7.5 cm. The surface dose decreased as the lead was positioned closer to the water surface and as the field size was increased. The variation in surface dose as a function of x-ray beam energy was only small but the maximum reduction occurred for the 100 kVp x-ray beam. For the 8 cm diameter field with the lead at 1 cm depth and using the 100 kVp x-ray beam, the surface dose was reduced to 0.898 of the surface dose in the water phantom only. Measured surface dose changes, using a Farmer-type ionization chamber, agreed with the Monte Carlo calculated doses. Calculated depth doses in water with a lead sheet positioned below the surface showed that the dose fall-off increased as the lead was positioned closer to the water surface as compared to the depth dose in the water phantom only. Monte Carlo calculations of the total x-ray beam spectrum at the water surface showed that the total fluence decreased due to a reduction in backscatter from within the water and very little backscatter from the lead. The mean energy of the x-ray spectrum varied less than 1 keV, with the lead at 1 cm beneath the water phantom surface. As the Monte Carlo calculations showed good agreement with the measured results, this method can be used to verify surface dose changes in clinical situations

  19. Association between cumulative radiation dose, adverse skin reactions, and changes in surface hemoglobin among women undergoing breast conserving therapy

    Directory of Open Access Journals (Sweden)

    Michael S. Chin

    2017-06-01

    Conclusion: HSI demonstrates promise in the assessment of skin dose as well as an objective measure of skin reaction. The ability to easily identify adverse skin reactions and to modify the treatment plan may circumvent the need for detrimental treatment breaks.

  20. Preliminary mortality survey from 1973 to 1977 of Japanese radiological technologists and analyses of the association of mortality with cumulative doses

    International Nuclear Information System (INIS)

    Aoyama, Takashi; Ishizaka, Masatsuna; Yamamoto, Yoichi; Kano, Eiichi; Nikaido, Osamu.

    1981-01-01

    The Japan Association of Radiologic Technologists reported that, from 1941 to 1978, 395 deaths occurred among Japanese radiological technologists who belong to the association. Using these data, Sakka, Kitabatake and colleagues, and the present authors studied mortality and cause of death among these technologists for 11 years from 1955 to 1965, for 7 years from 1966 to 1972, and for 5 years from 1973 to 1977, respectively. In general, the number of cancer deaths in the three studies was less than expected. However, Kitabatake et al. and the present authors found that deaths from skin cancer were significantly more frequent than expected. The present authors recently estimated the cumulative doses of radiation exposure for the majority of deaths (268 out of 395). The mean dose of radiation related to cancer deaths was then compared with that for non-cancer deaths. Also the proportional mortality ratios for cancers were observed in relation to the estimated dose level. In the present study, however, statistical tests to assess for the relationship between mortality and dose of radiation exposure showed no correlation, for the majority of deaths from cancer. (author)

  1. Effect of Low Dose Lead (Pb) Administration on Tail Immersion Test ...

    African Journals Online (AJOL)

    olayemitoyin

    Effect of Low Dose Lead (Pb) Administration on Tail ... Acute and sub-acute effects of lead are caused by relatively large ... As such, the brain is the organ most studied in lead toxicity. ..... inflammatory Properties of Hydro-alcohol Extract of.

  2. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    Energy Technology Data Exchange (ETDEWEB)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J. (Ontario Cancer Institute, Princess Margaret Hospital, Toronto (Canada))

    1991-05-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing.

  3. The leaded apron revisited: does it reduce gonadal radiation dose in dental radiology

    International Nuclear Information System (INIS)

    Wood, R.E.; Harris, A.M.; van der Merwe, E.J.; Nortje, C.J.

    1991-01-01

    A tissue-equivalent anthropomorphic human phantom was used with a lithium fluoride thermoluminescent dosimetry system to evaluate the radiation absorbed dose to the ovarian and testicular region during dental radiologic procedures. Measurements were made with and without personal lead shielding devices consisting of thyroid collar and apron of 0.25 mm lead thickness equivalence. The radiation absorbed dose with or without lead shielding did not differ significantly from control dosimeters in vertex occlusal and periapical views (p greater than 0.05). Personal lead shielding devices did reduce gonadal dose in the case of accidental exposure (p less than 0.05). A leaded apron of 0.25 mm lead thickness equivalent was permeable to radiation in direct exposure testing

  4. An international pooled analysis for obtaining a benchmark dose for environmental lead exposure in children

    DEFF Research Database (Denmark)

    Budtz-Jørgensen, Esben; Bellinger, David; Lanphear, Bruce

    2013-01-01

    Lead is a recognized neurotoxicant, but estimating effects at the lowest measurable levels is difficult. An international pooled analysis of data from seven cohort studies reported an inverse and supra-linear relationship between blood lead concentrations and IQ scores in children. The lack...... of a clear threshold presents a challenge to the identification of an acceptable level of exposure. The benchmark dose (BMD) is defined as the dose that leads to a specific known loss. As an alternative to elusive thresholds, the BMD is being used increasingly by regulatory authorities. Using the pooled data...... yielding lower confidence limits (BMDLs) of about 0.1-1.0 μ g/dL for the dose leading to a loss of one IQ point. We conclude that current allowable blood lead concentrations need to be lowered and further prevention efforts are needed to protect children from lead toxicity....

  5. Dose monitoring using the DICOM structured report: assessment of the relationship between cumulative radiation exposure and BMI in abdominal CT

    International Nuclear Information System (INIS)

    Boos, J.; Lanzman, R.S.; Meineke, A.; Heusch, P.; Sawicki, L.M.; Antoch, G.; Kröpil, P.

    2015-01-01

    Aim: To perform a systematic, large-scale analysis using the Digital Imaging and Communication in Medicine structured report (DICOM-SR) to assess the relationship between body mass index (BMI) and radiation exposure in abdominal CT. Materials and methods: A retrospective analysis of DICOM-SR of 3121 abdominal CT examinations between April 2013 and March 2014 was performed. All examinations were conducted using a 128 row CT system. Patients (mean age 61 ± 15 years) were divided into five groups according to their BMI: group A <20 kg/m 2 (underweight), group B 20–25 kg/m 2 (normal weight), group C 25–30 kg/m 2 (overweight), group D 30–35 kg/m 2 (obese), and group E > 35 kg/m 2 (extremely obese). CT dose index (CTDI vol ) and dose–length product (DLP) were compared between all groups and matched to national diagnostic reference values. Results: The mean CTDI vol and DLP were 5.4 ± 2.9 mGy and 243 ± 153 mGy·cm in group A, 6 ± 3.6 mGy and 264 ± 179 mGy• cm in group B, 7 ± 3.6 mGy and 320 ± 180 mGy• cm in group C, 8.1 ± 5.2 mGy and 375 ± 306 mGy• cm in group D, and 10 ± 8 mGy and 476 ± 403 mGy• cm in group E, respectively. Except for group A versus group B, CTDI vol and DLP differed significantly between all groups (p<0.05). Significantly more CTDI vol values exceeded national diagnostic reference values in groups D and E (2.1% and 6.3%) compared to group B (0.5%, p<0.05). Conclusion: DICOM-SR is a comprehensive, fast, and reproducible way to analyse dose-related data at CT. It allows for automated evaluation of radiation dose in a large study population. Dose exposition is related to the patient's BMI and is increased by up to 96% for extremely obese patients undergoing abdominal CT. - Highlights: • DICOM-SR was used to implement automatic CT-dose monitoring. • DICOM-SR allowed for a fast and comprehensive analysis of CT dose data. • Radiation exposure for abdominal CT was increased by up to 96% for

  6. Investigation of practical approaches to evaluating cumulative dose for cone beam computed tomography (CBCT) from standard CT dosimetry measurements: a Monte Carlo study.

    Science.gov (United States)

    Abuhaimed, Abdullah; Martin, Colin J; Sankaralingam, Marimuthu; Gentle, David J

    2015-07-21

    A function called Gx(L) was introduced by the International Commission on Radiation Units and Measurements (ICRU) Report-87 to facilitate measurement of cumulative dose for CT scans within long phantoms as recommended by the American Association of Physicists in Medicine (AAPM) TG-111. The Gx(L) function is equal to the ratio of the cumulative dose at the middle of a CT scan to the volume weighted CTDI (CTDIvol), and was investigated for conventional multi-slice CT scanners operating with a moving table. As the stationary table mode, which is the basis for cone beam CT (CBCT) scans, differs from that used for conventional CT scans, the aim of this study was to investigate the extension of the Gx(L) function to CBCT scans. An On-Board Imager (OBI) system integrated with a TrueBeam linac was simulated with Monte Carlo EGSnrc/BEAMnrc, and the absorbed dose was calculated within PMMA, polyethylene (PE), and water head and body phantoms using EGSnrc/DOSXYZnrc, where the body PE body phantom emulated the ICRU/AAPM phantom. Beams of width 40-500 mm and beam qualities at tube potentials of 80-140 kV were studied. Application of a modified function of beam width (W) termed Gx(W), for which the cumulative dose for CBCT scans f (0) is normalized to the weighted CTDI (CTDIw) for a reference beam of width 40 mm, was investigated as a possible option. However, differences were found in Gx(W) with tube potential, especially for body phantoms, and these were considered to be due to differences in geometry between wide beams used for CBCT scans and those for conventional CT. Therefore, a modified function Gx(W)100 has been proposed, taking the form of values of f (0) at each position in a long phantom, normalized with respect to dose indices f 100(150)x measured with a 100 mm pencil ionization chamber within standard 150 mm PMMA phantoms, using the same scanning parameters, beam widths and positions within the phantom. f 100(150)x averages the dose resulting from

  7. Cumulative effective radiation dose received by blunt trauma patients arriving to a military level I trauma center from point of injury and interhospital transfers.

    Science.gov (United States)

    Van Arnem, Kerri A; Supinski, David P; Tucker, Jonathan E; Varney, Shawn

    2016-12-01

    Trauma patients sustaining blunt injuries are exposed to multiple radiologic studies. Evidence indicates that the risk of cancer from exposure to ionizing radiation rises in direct proportion to the cumulative effective dose (CED) received. The purpose of this study is to quantify the amount of ionizing radiation accumulated when arriving directly from point of injury to San Antonio Military Medical Center (SAMMC), a level I trauma center, compared with those transferred from other facilities. A retrospective record review was conducted from 1st January 2010 through 31st December 2012. The SAMMC trauma registry, electronic medical records, and the digital radiology imaging system were searched for possible candidates. The medical records were then analyzed for sex, age, mechanism of injury, received directly from point of injury (direct group), transfer from another medical facility (transfer group), computed tomographic scans received, dose-length product, CED of radiation, and injury severity score. A diagnostic imaging physicist then calculated the estimated CED each subject received based on the dose-length product of each computed tomographic scan. A total of 300 patients were analyzed, with 150 patients in the direct group and 150 patients in the transfer group. Both groups were similar in age and sex. Patients in the transfer group received a significantly greater CED of radiation compared with the direct group (mean, 37.6 mSv vs 28 mSv; P=.001). The radiation received in the direct group correlates with a lifetime attributable risk (LAR) of 1 in 357 compared with the transfer group with an increase in LAR to 1 in 266. Patients transferred to our facility received a 34% increase in ionizing radiation compared with patients brought directly from the injury scene. This increased dose of ionizing radiation contributes to the LAR of cancer and needs to be considered before repeating imaging studies. III. Published by Elsevier Inc.

  8. Radiation exposure of radiologists during angiography: Dose measurements outside the lead apron

    International Nuclear Information System (INIS)

    Fischer, H.; Przetak, C.; Teubert, G.; Ewen, K.; Moedder, U.

    1995-01-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r=0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons. (orig.) [de

  9. Dosimetric perturbations of a lead shield for surface and interstitial high-dose-rate brachytherapy

    International Nuclear Information System (INIS)

    Candela-Juan, Cristian; Granero, Domingo; Vijande, Javier; Ballester, Facundo; Perez-Calatayud, Jose; Rivard, Mark J

    2014-01-01

    In surface and interstitial high-dose-rate brachytherapy with either 60 Co, 192 Ir, or 169 Yb sources, some radiosensitive organs near the surface may be exposed to high absorbed doses. This may be reduced by covering the implants with a lead shield on the body surface, which results in dosimetric perturbations. Monte Carlo simulations in Geant4 were performed for the three radionuclides placed at a single dwell position. Four different shield thicknesses (0, 3, 6, and 10 mm) and three different source depths (0, 5, and 10 mm) in water were considered, with the lead shield placed at the phantom surface. Backscatter dose enhancement and transmission data were obtained for the lead shields. Results were corrected to account for a realistic clinical case with multiple dwell positions. The range of the high backscatter dose enhancement in water is 3 mm for 60 Co and 1 mm for both 192 Ir and 169 Yb. Transmission data for 60 Co and 192 Ir are smaller than those reported by Papagiannis et al (2008 Med. Phys. 35 4898–4906) for brachytherapy facility shielding; for 169 Yb, the difference is negligible. In conclusion, the backscatter overdose produced by the lead shield can be avoided by just adding a few millimetres of bolus. Transmission data provided in this work as a function of lead thickness can be used to estimate healthy organ equivalent dose saving. Use of a lead shield is justified. (paper)

  10. Influence on the individual dose by using lead aprons at hemodynamic services

    International Nuclear Information System (INIS)

    Alonso, Thessa Cristina; Silva, Teogenes Augusto da

    2005-01-01

    In interventional radiology, heart catheterism procedures are done with therapeutic and diagnosis purposes. In those medical practices, staff members are required to wear lead aprons for individual protection beside other protective equipment like thyroid lead protector, lead eyeglasses and gloves. The proper and suitable equipment is chosen according to the exam type. Exposure of medical team is under discussion concerned to use of the individual dosimeter under or on the lead apron and the need to apply a dose correction factor of 0.01 in the first case to estimate the effective dose. This work investigates personal doses of medical team in interventional radiology services of two hospitals in Belo Horizonte. Individual thermoluminescent dosimeters were fastened under and on lead aprons during one month period to measure the personal dose equivalents, Hp(10). Results indicate that the dose correction factor due to the lead apron presence is not a proper correction for interventional radiology exams; different factors are suggested if the worker is closer or not so close the x-ray beam. Additionally, it is emphasized that the use of adequate protective aprons and conscientious behavior according to a safety culture can minimize the radiation exposure of those professionals. (author)

  11. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    Energy Technology Data Exchange (ETDEWEB)

    Lee, J [Dept. of Radiation Oncology, Konkuk University Medical Center, Seoul (Korea, Republic of); Chung, J [Dept. of Radiation Oncology, Seoul National University Bundang Hospital, Seongnam (Korea, Republic of)

    2015-06-15

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy.

  12. SU-E-T-802: Verification of Implanted Cardiac Pacemaker Doses in Intensity-Modulated Radiation Therapy: Dose Prediction Accuracy and Reduction Effect of a Lead Sheet

    International Nuclear Information System (INIS)

    Lee, J; Chung, J

    2015-01-01

    Purpose: To verify delivered doses on the implanted cardiac pacemaker, predicted doses with and without dose reduction method were verified using the MOSFET detectors in terms of beam delivery and dose calculation techniques in intensity-modulated radiation therapy (IMRT). Methods: The pacemaker doses for a patient with a tongue cancer were predicted according to the beam delivery methods [step-and-shoot (SS) and sliding window (SW)], intensity levels for dose optimization, and dose calculation algorithms. Dosimetric effects on the pacemaker were calculated three dose engines: pencil-beam convolution (PBC), analytical anisotropic algorithm (AAA), and Acuros-XB. A lead shield of 2 mm thickness was designed for minimizing irradiated doses to the pacemaker. Dose variations affected by the heterogeneous material properties of the pacemaker and effectiveness of the lead shield were predicted by the Acuros-XB. Dose prediction accuracy and the feasibility of the dose reduction strategy were verified based on the measured skin doses right above the pacemaker using mosfet detectors during the radiation treatment. Results: The Acuros-XB showed underestimated skin doses and overestimated doses by the lead-shield effect, even though the lower dose disagreement was observed. It led to improved dose prediction with higher intensity level of dose optimization in IMRT. The dedicated tertiary lead sheet effectively achieved reduction of pacemaker dose up to 60%. Conclusion: The current SS technique could deliver lower scattered doses than recommendation criteria, however, use of the lead sheet contributed to reduce scattered doses.Thin lead plate can be a useful tertiary shielder and it could not acuse malfunction or electrical damage of the implanted pacemaker in IMRT. It is required to estimate more accurate scattered doses of the patient with medical device to design proper dose reduction strategy

  13. The cumulative cost of additional wakefulness: dose-response effects on neurobehavioral functions and sleep physiology from chronic sleep restriction and total sleep deprivation

    Science.gov (United States)

    Van Dongen, Hans P A.; Maislin, Greg; Mullington, Janet M.; Dinges, David F.

    2003-01-01

    OBJECTIVES: To inform the debate over whether human sleep can be chronically reduced without consequences, we conducted a dose-response chronic sleep restriction experiment in which waking neurobehavioral and sleep physiological functions were monitored and compared to those for total sleep deprivation. DESIGN: The chronic sleep restriction experiment involved randomization to one of three sleep doses (4 h, 6 h, or 8 h time in bed per night), which were maintained for 14 consecutive days. The total sleep deprivation experiment involved 3 nights without sleep (0 h time in bed). Each study also involved 3 baseline (pre-deprivation) days and 3 recovery days. SETTING: Both experiments were conducted under standardized laboratory conditions with continuous behavioral, physiological and medical monitoring. PARTICIPANTS: A total of n = 48 healthy adults (ages 21-38) participated in the experiments. INTERVENTIONS: Noctumal sleep periods were restricted to 8 h, 6 h or 4 h per day for 14 days, or to 0 h for 3 days. All other sleep was prohibited. RESULTS: Chronic restriction of sleep periods to 4 h or 6 h per night over 14 consecutive days resulted in significant cumulative, dose-dependent deficits in cognitive performance on all tasks. Subjective sleepiness ratings showed an acute response to sleep restriction but only small further increases on subsequent days, and did not significantly differentiate the 6 h and 4 h conditions. Polysomnographic variables and delta power in the non-REM sleep EEG-a putative marker of sleep homeostasis--displayed an acute response to sleep restriction with negligible further changes across the 14 restricted nights. Comparison of chronic sleep restriction to total sleep deprivation showed that the latter resulted in disproportionately large waking neurobehavioral and sleep delta power responses relative to how much sleep was lost. A statistical model revealed that, regardless of the mode of sleep deprivation, lapses in behavioral alertness

  14. The Effect of Total Cumulative Dose, Number of Treatment Cycles, Interval between Injections, and Length of Treatment on the Frequency of Occurrence of Antibodies to Botulinum Toxin Type A in the Treatment of Muscle Spasticity

    Science.gov (United States)

    Bakheit, Abdel Magid O.; Liptrot, Anthea; Newton, Rachel; Pickett, Andrew M.

    2012-01-01

    A large cumulative dose of botulinum toxin type A (BoNT-A), frequent injections, a short interval between treatment cycles, and a long duration of treatment have all been suggested, but not confirmed, to be associated with a high incidence of neutralizing antibodies to the neurotoxin. The aim of this study was to investigate whether these…

  15. Influence of lead apron shielding on absorbed doses from cone-beam computed tomography.

    Science.gov (United States)

    Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk

    2017-06-01

    The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO® phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500®, ProMax® 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax® 3D with shielding, the ED was 149 µSv, and for the examination protocol without shielding 148 µSv (SD = 0.31 µSv). For the CS 9500®, the ED was 88 and 86 µSv (SD = 0.95 µSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam. © The Author 2016. Published by Oxford University Press. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  16. Influence of lead apron shielding on absorbed doses from cone-beam computed tomography

    International Nuclear Information System (INIS)

    Rottke, Dennis; Andersson, Jonas; Ejima, Ken-Ichiro; Sawada, Kunihiko; Schulze, Dirk

    2017-01-01

    The aim of the present work was to investigate absorbed and to calculate effective doses (EDs) in cone-beam computed tomography (CBCT). The study was conducted using examination protocols with and without lead apron shielding. A full-body male RANDO"R phantom was loaded with 110 GR200A thermoluminescence dosemeter chips at 55 different sites and set up in two different CBCT systems (CS 9500"R, ProMax"R 3D). Two different protocols were performed: the phantom was set up (1) with and (2) without a lead apron. No statistically significant differences in organ and absorbed doses from regions outside the primary beam could be found when comparing results from exposures with and without lead apron shielding. Consequently, calculating the ED showed no significant differences between the examination protocols with and without lead apron shielding. For the ProMax"R 3D with shielding, the ED was 149 μSv, and for the examination protocol without shielding 148 μSv (SD = 0.31 μSv). For the CS 9500"R, the ED was 88 and 86 μSv (SD = 0.95 μSv), respectively, with and without lead apron shielding. The results revealed no statistically significant differences in the absorbed doses between examination with and without lead apron shielding, especially in organs outside the primary beam. (authors)

  17. Effect of low dose Lead (Pb) administration on tail immersion test ...

    African Journals Online (AJOL)

    Effect of low dose Lead (Pb) administration on tail immersion test and ... subtle decline in cognitive function, and adverse reproductive outcome at low blood Pb level. ... Twenty adult Wistar rats of both sexes (weight 150g to 200g) were used.

  18. Radiation dose reduction to the male gonads during MDCT: the effectiveness of a lead shield.

    Science.gov (United States)

    Hohl, Christian; Mahnken, Andreas H; Klotz, Ernst; Das, Marco; Stargardt, Achim; Mühlenbruch, Georg; Schmidt, Thorsten; Günther, Rolf W; Wildberger, Joachim E

    2005-01-01

    Our study was designed to quantify the effect of a standard gonad shield on the testicular radiation exposure due to scatter during routine abdominopelvic MDCT. Routine abdominopelvic MDCT was performed in 34 patients with gonadal lead shielding and 32 patients without this shielding; the testes were not exposed to the direct beam during the examination. We estimated the testicular dose administered with thermoluminescent dosimetry, taking into account each patient's body weight and body mass index (BMI). With a 1-mm lead shield, the mean testicular dose was reduced from 2.40 to 0.32 mSv, a reduction of 87%. The difference was found to be statistically significant (p Shielding the male gonads reduces the testicular radiation dose during abdominopelvic MDCT significantly and can be recommended for routine use.

  19. Lifetime exposure to low doses of lead in rats: effect on selected parameters of carbohydrate metabolism.

    Science.gov (United States)

    Nováková, Jaroslava; Lukačínová, Agnesa; Lovásová, Eva; Cimboláková, Iveta; Rácz, Oliver; Ništiar, František

    2015-05-01

    The aim of the study was to assess the effects of exposure to low doses of lead dissolved in drinking water (average daily dose of 2.2 mg kg(-1) day(-1)) on selected carbohydrate metabolism parameters in 20 wistar rats. Animals were divided into two groups - control (C) (group drinking clear water) and experimental group (Pb; group exposed to low doses of lead acetate in a concentration of 100 μmol l(-1) of drinking water). In this study, we studied the biochemical parameters (glucose, haemoglobin (Hb), glycated haemoglobin (HbA1c), lactate dehydrogenase (LDH) and amylase (AMS)) in rat blood. Glucose and Hb concentration and AMS activity decreased, LDH activity increased but HbA1c concentration levels did not change in rats exposed to lead. Our results well documented that lifetime exposure to lead affected carbohydrate metabolism of rats. Some parameters like concentration of Hb as well as activities of AMS and LDH are useful markers of intoxication of rats with lead. For the evaluation of results (e.g. AMS), not only the data at the end of the experiment should be taken into account but also the entire duration of trials (i.e. more time steps) that makes results more objective should be considered. © The Author(s) 2013.

  20. Dose rate reduction using epoxy mixed lead shielding: experimental and theoretical determination of its shielding effectiveness

    International Nuclear Information System (INIS)

    Yadav, R.K.B.; Prasad, S.K.; Babu, K.S.; Hardiya, M.R.; Ullas, O.P.

    2010-01-01

    Full text: High background radiation field exists in Water Treatment Area (WTA) of Rod Cutting Building (RCB) in Cirus due to beta, gamma contamination on its floor. The high contamination on sides of wall and on floor is primarily due to deposition of activity generated during the regeneration of old mixed bed cartridges earlier (before year 1985) and presently due to deposition of contaminants by sump overflowing, wastes generated during maintenance/servicing of circulating pumps. RCB-WTA contribution to collective dose in present situation is up to 30% of the total collective dose of Cirus. Various options such as chipping of top layer of concrete floor of a sample area, in-situ placing of slab of cement and lead shot mixture were considered. In this case the man-rem consumption was high as radiation dose rate on concrete chip was 0.4 mGy/h and air activity generated was high, that too long lived with 137 Cs-as main constituent. The dose reduction factor was 1.7. In the second option the reduction in dose rate was insignificant and in-situ pouring of concrete consumed high collective dose. Hence above two options were not acceptable. Therefore the idea of tiling the contaminated floor with prefabricated epoxy mixed lead shots was accepted from ALARA point of view. It was concluded that pre-fabricated slabs of epoxy mixed lead slab of 25 mm thickness can be laid in RCB area to achieve a dose rate reduction factor of approximately five at a height of 30 cm above floor. This will result in a reduction of Person-mSv consumption in RCB by a factor of 5-10. These slabs of different thickness were fabricated outside RCB and were tested for shielding effectiveness experimentally by using radiation source and theoretically using MCNP code. Dose reduction factor of five for a point source, obtained experimentally for epoxy mixed lead shots was very near to value obtained by theoretical simulation. An extended calculation for an area source using this MCNP model gives a

  1. Cumulative radiation effect

    International Nuclear Information System (INIS)

    Kirk, J.; Cain, O.; Gray, W.M.

    1977-01-01

    Cumulative Radiation Effect (CRE) represents a scale of accumulative sub-tolerance radiation damage, with a unique value of the CRE describing a specific level of radiation effect. Computer calculations have been used to simplify the evaluation of problems associated with the applications of the CRE-system in radiotherapy. In a general appraisal of the applications of computers to the CRE-system, the various problems encountered in clinical radiotherapy have been categorised into those involving the evaluation of a CRE at a point in tissue and those involving the calculation of CRE distributions. As a general guide, the computer techniques adopted at the Glasgow Institute of Radiotherapeutics for the solution of CRE problems are presented, and consist basically of a package of three interactive programs for point CRE calculations and a Fortran program which calculates CRE distributions for iso-effect treatment planning. Many examples are given to demonstrate the applications of these programs, and special emphasis has been laid on the problem of treating a point in tissue with different doses per fraction on alternate treatment days. The wide range of possible clinical applications of the CRE-system has been outlined and described under the categories of routine clinical applications, retrospective and prospective surveys of patient treatment, and experimental and theoretical research. Some of these applications such as the results of surveys and studies of time optimisation of treatment schedules could have far-reaching consequences and lead to significant improvements in treatment and cure rates with the minimum damage to normal tissue. (author)

  2. Myelin basic protein in brains of rats with low dose lead encephalopathy

    Energy Technology Data Exchange (ETDEWEB)

    Sundstroem, R; Karlsson, B

    1987-02-01

    In the present study control rats and lead exposed rats which did not have any retardation of growth were examined by radioimmunological assay of myelin basic protein (MBP) of homogenates of cerebrum and cerebellum at 30, 60 and 120 days of age. Lead was administered on postnatal days 1-15 by daily intraperitoneal injections of 10 mg lead nitrate/kg body weight. This lead dose results in light microscopically discernible hemorrhagic encephalopathy in the cerebellum of 15-day old rats, but does not induce growth retardation. The controls were injected with vehicle only. The amount of lead in the blood and brain homogenates of lead-exposed and control rats 15-200 days old was estimated by atomic absorption spectrophotometry. Significant differences between the lead-exposed and control rats were not found in the cerebral or cerebellar content of MBP. Considering the results of previous investigations, the findings do not exclude a hypo-myelinating effect of lead, but they suggest that exposure to lead without concomitant malnutrition does not cause hypo-myelination in the cerebrum and cerebellum of the developing rat.

  3. Effect of usual lead apron in decreasing dose rate in nuclear medicine department

    Energy Technology Data Exchange (ETDEWEB)

    Momennezhad, M.; Ghazikhanloo, K.; Zakavi, S.R. [Mashhad Univ. of Medical Sciences (Iran, Islamic Republic of)

    2006-07-01

    Full text of publication follows: Introduction: In a busy nuclear medicine department personnel exposure to radiation is inevitable during patient positioning and radiotracer preparation. There is controversy regarding usage of usual lead aprons with respect to penetrating gamma rays used in nuclear medicine departments as well as production of characteristic lead x-ray from aprons.This study tries to evaluate the effect of 0.5 mm lead apron on dose reduction. Methods and materials: We used three point sources usual radioisotopes used in nuclear medicine departments (99 mTc, 201 Tl and 131 I) and a single head L.F.O.V. gamma camera (S.M.V., D.S.X.) was used for counting purposes. The count rate for each source was about 20 K count/sec in air and in a brain water phantom. All point sources were placed at a distance of 3 meters, parallel to the center of the detector. The collimator was removed and imaging was performed for 1 min with and without lead apron on the detector. Lead apron covered all field of view of the detector. Each imaging was repeated 3 times and mean count was obtained for each radioisotope. The measurements were accomplished from full spectrum and specific region of spectrum such as characteristic lead x rays region (88 keV 20%) with and without apron. Result and Discussion: The measurement and comparison of count rates (count/min) for each source in different conditions (with and without apron source in air and in water phantom) showed that count rates were reduced in air about 77.3%, 84.2% and 40.8% for 99 mTc, 201 Tl and 131 I respectively. The reduction in count rates when sources placed in brain water phantom were 83.5%, 87% and 53.7% for the same isotope respectively. As the main source of radiation for personnel is from scattered photon and with respect to about 83% of count rate reduction using lead aprons for 99 mTc, it is expected that wearing lead apron significantly decrease dose rate. Conclusion: Our study showed that lead aprons

  4. Effect of usual lead apron in decreasing dose rate in nuclear medicine department

    International Nuclear Information System (INIS)

    Momennezhad, M.; Ghazikhanloo, K.; Zakavi, S.R.

    2006-01-01

    Full text of publication follows: Introduction: In a busy nuclear medicine department personnel exposure to radiation is inevitable during patient positioning and radiotracer preparation. There is controversy regarding usage of usual lead aprons with respect to penetrating gamma rays used in nuclear medicine departments as well as production of characteristic lead x-ray from aprons.This study tries to evaluate the effect of 0.5 mm lead apron on dose reduction. Methods and materials: We used three point sources usual radioisotopes used in nuclear medicine departments (99 mTc, 201 Tl and 131 I) and a single head L.F.O.V. gamma camera (S.M.V., D.S.X.) was used for counting purposes. The count rate for each source was about 20 K count/sec in air and in a brain water phantom. All point sources were placed at a distance of 3 meters, parallel to the center of the detector. The collimator was removed and imaging was performed for 1 min with and without lead apron on the detector. Lead apron covered all field of view of the detector. Each imaging was repeated 3 times and mean count was obtained for each radioisotope. The measurements were accomplished from full spectrum and specific region of spectrum such as characteristic lead x rays region (88 keV 20%) with and without apron. Result and Discussion: The measurement and comparison of count rates (count/min) for each source in different conditions (with and without apron source in air and in water phantom) showed that count rates were reduced in air about 77.3%, 84.2% and 40.8% for 99 mTc, 201 Tl and 131 I respectively. The reduction in count rates when sources placed in brain water phantom were 83.5%, 87% and 53.7% for the same isotope respectively. As the main source of radiation for personnel is from scattered photon and with respect to about 83% of count rate reduction using lead aprons for 99 mTc, it is expected that wearing lead apron significantly decrease dose rate. Conclusion: Our study showed that lead aprons

  5. Comparison between steel and lead shieldings for radiotherapy rooms regarding neutron doses to patients

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G., E-mail: eng.cavaliere@gmail.com, E-mail: ggrprojetos@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil). Secao de Engenharia Nuclear; Silva, A.X., E-mail: ademir@con.ufrj.br [Coordenacao dos Programas de Pos-Graduacao em Engenharia (COPPE/UFRJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H *(10){sub n}, within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5 x 5 cm{sup 2}, 10 x 10 cm{sup 2}, 20 x 20 cm{sup 2}, 30 x 30 cm{sup 2} and 40 x 40 cm{sup 2} openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H *(10){sub n} at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation. (author)

  6. Comparison between steel and lead shieldings for radiotherapy rooms regarding neutron doses to patients

    International Nuclear Information System (INIS)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G.

    2015-01-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H *(10) n , within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5 x 5 cm 2 , 10 x 10 cm 2 , 20 x 20 cm 2 , 30 x 30 cm 2 and 40 x 40 cm 2 openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H *(10) n at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation. (author)

  7. Characterization of a lead breast shielding for dose reduction in computed tomography

    Energy Technology Data Exchange (ETDEWEB)

    Correia, Paula Duarte; Brochi, Marco Aurelio Corte; Azevedo-Marques, Paulo Mazzoncini de, E-mail: pauladuarte@usp.br [Universidade de Sao Paulo (FM/RSP), Ribeirao Preto, SP (Brazil). Faculdade de Medicina; Granzotti, Cristiano Roberto Fabri; Santos, Yago da Silva [Universidade de Sao Paulo (FFCLRP/RSP), Ribeirao Preto, SP (Brazil). Faculdade de Filosofia, Ciencias e Letras

    2014-07-15

    Objective: several studies have been published regarding the use of bismuth shielding to protect the breast in computed tomography (CT) scans and, up to the writing of this article, only one publication about barium shielding was found. The present study was aimed at characterizing, for the first time, a lead breast shielding. Materials and methods: the percentage dose reduction and the influence of the shielding on quantitative imaging parameters were evaluated. Dose measurements were made on a CT equipment with the aid of specific phantoms and radiation detectors. A processing software assisted in the qualitative analysis evaluating variations in average CT number and noise on images. Results: the authors observed a reduction in entrance dose by 30% and in CTDIvol by 17%. In all measurements, in agreement with studies in the literature, the utilization of cotton fiber as spacer object reduced significantly the presence of artifacts on the images. All the measurements demonstrated increase in the average CT number and noise on the images with the presence of the shielding. Conclusion: as expected, the data observed with the use of lead shielding were of the same order as those found in the literature about bismuth shielding. (author)

  8. Cumulative dose of hydroxychloroquine is associated with a decrease of resting heart rate in patients with systemic lupus erythematosus: a pilot study.

    Science.gov (United States)

    Cairoli, E; Danese, N; Teliz, M; Bruzzone, M J; Ferreira, J; Rebella, M; Cayota, A

    2015-10-01

    The use of hydroxychloroquine (HCQ) in patients with systemic lupus erythematosus (SLE) offers a wide range of benefits. However, there are evidence in favour of cardiotoxicity, including heart conduction disturbances and congestive heart failure. To determine the effects of HCQ in the resting heart rate (RHR) of SLE patients. Included were patients with non active SLE, with a sedentary lifestyle and treated with HCQ. Excluded were patients on beta blocker treatment, trained patients, pacemaker's users and patients with clinical or analytical evidence of anemia, renal disease, obstructive pulmonary disease, obesity, uncontrolled thyroid disease, fever or current infection. Standard 12-lead electrocardiogram was performed in the resting condition (supine decubitus and orthostatic position). Comparison between groups was performed using Mann-Whitney U test. A multiple linear regression was performed. A p value 365 g). Non significant differences were found in age, sex, prednisone dose or SLEDAI. The mean RHR was 73 ± 6 beats/min in the low-HCQ and 65 ± 7 beats/min in the high-HCQ, with a significant decrease of 11% (p = 0.003). In multiple linear regressions, there were non significant association between the decrease of RHR and prednisone dose, age, SLEDAI or TSH, but there was significant association between RHR and CD-HCQ (p = 0.024) and RHR and time of exposure to HCQ (p = 0.029). CD-HCQ higher than 365 g was associated with a significant decrease (11%) in RHR in non-active SLE patients, although a larger prospective study is required to allow more definitive conclusions. © The Author(s) 2015 Reprints and permissions: sagepub.co.uk/journalsPermissions.nav.

  9. Six-year longitudinal study of pathways leading to explosive anger involving the traumas of recurrent conflict and the cumulative sense of injustice in Timor-Leste.

    Science.gov (United States)

    Silove, Derrick; Mohsin, Mohammed; Tay, Alvin Kuowei; Steel, Zachary; Tam, Natalino; Savio, Elisa; Da Costa, Zelia Maria; Rees, Susan

    2017-10-01

    Cumulative evidence suggests that explosive anger may be a common reaction among survivors of mass conflict. However, little is known about the course of explosive anger in the years following mass conflict, or the psychosocial factors that influence the trajectory of that reaction pattern. We examined these issues in a 6-year longitudinal study (2004-2010) conducted among adult residents of a rural and an urban village in Timor-Leste (n = 1022). We derived a brief, context-specific index of explosive anger using qualitative methods. Widely used measures of post-traumatic stress disorder (PTSD) and severe psychological distress were calibrated to the Timor context. We developed an index of the cumulative sense of injustice related to consecutive historical periods associated with conflict in Timor-Leste. We applied partial structural equation modeling (SEM) to examine pathways from baseline explosive anger, socio-demographic factors, recurrent trauma, mental health indices (PTSD, severe psychological distress) and the sense of injustice, to explosive anger. Half of the sample with explosive anger at baseline continued to report that reaction pattern after 6 years; and a third of those who did not report explosive anger at baseline developed the response by follow-up. A symmetrical pattern of younger age, female gender and the trauma count for the preceding historical period predicted explosive anger at each assessment point. The sense of injustice was related to explosive anger at follow-up. Explosive anger was associated with impairment in functioning and conflict with the intimate partner and wider family. Sampling constraints caution against generalizing our findings to other populations. Nevertheless, our data suggest that explosive anger may persist for a prolonged period of time following mass conflict and that the response pattern is initiated and maintained by recurrent trauma exposure associated with a sense of injustice. Averting recurrence of mass

  10. Influence of lead apron shielding on absorbed doses from panoramic radiography.

    Science.gov (United States)

    Rottke, D; Grossekettler, L; Sawada, K; Poxleitner, P; Schulze, D

    2013-01-01

    This study investigated the absorbed doses in a full anthropomorphic body phantom from two different panoramic radiography devices, performing protocols with and without applying a lead apron. A RANDO(®) full body phantom (Alderson Research Laboratories Inc., Stamford, CT) was equipped with 110 thermoluminescent dosemeters at 55 different sites and set up in two different panoramic radiography devices [SCANORA(®) three-dimensional (3D) (SOREDEX, Tuusula, Finland) and ProMax(®) 3D (Planmeca, Helsinki, Finland)] and exposed. Two different protocols were performed in the two devices. The first protocol was performed without any lead shielding, whereas the phantom was equipped with a standard adult lead apron for the second protocol. A two-tailed paired samples t-test for the SCANORA 3D revealed that there is no difference between the protocol using lead apron shielding (m = 87.99, s = 102.98) and the protocol without shielding (m = 87.34, s = 107.49), t(54) = -0.313, p > 0.05. The same test for the ProMax 3D showed that there is also no difference between the protocol using shielding (m = 106.48, s = 117.38) and the protocol without shielding (m = 107.75, s = 114,36), t(54) = 0.938, p > 0.05. In conclusion, the results of this study showed no statistically significant differences between a panoramic radiography with or without the use of lead apron shielding.

  11. Estimation of the effects of a lead vest on dose reduction for radiation workers using Monte Carlo calculations

    International Nuclear Information System (INIS)

    Young-khi, Lim; Byoung-il, Lee; Jeong-in, Kim

    2008-01-01

    Full text: In the field of medical diagnosis or treatments using radiations, lead vests or aprons are widely used to protect the patients or workers from unwanted irradiation. Also, in nuclear power plants, it is recommended that the workers should wear a lead vest to reduce the dose for working in high radiation area. Generally, personal dosimeters were used to estimate the doses of workers but these cannot give the absolute values. So, measured values should be modified by comparing the reference conditions with conversion factors. Many trials to estimate the doses of workers with lead shield using two or more dosimeters at different locations were done but these had limitations. Through this study the personal dose with/without a lead vest and the effectiveness were evaluated by Monte Carlo methods. A lead vest which had been used at several nuclear sites was modelled with MIRD-V and typical Korean voxel phantom using MCNP-5 transport code. Organ doses were calculated in AP, PA, RLAT, LLAT irradiation geometry for several parallel photon beams. Also irradiation experiments were carried out using real typical Korean phantom with the lead vest and the results were compared with those calculated by simulations. In most cases, the lead vest decreases the organ doses about 30%. For low energy, the lead vest is very effective to reduce the dose but it is not so good for high energy photon shielding. For thyroids, the doses to high energy photons increased by 5% on the contrary. This study may be applied to the better design of personal shielding and dose estimation procedures for practical use. (author)

  12. A comparison of dose savings of lead and lightweight aprons for shielding of 99m-Technetium radiation

    International Nuclear Information System (INIS)

    Warren-Forward, H.; Cardew, P.; Smith, B.; Clack, L.; McWhirter, K.; Johnson, S.; Wessel, K.

    2007-01-01

    Nuclear medicine technologists (NMTs) have the highest effective doses of radiation among medical workers. With increase in the use of lightweight materials in diagnostic radiography, the aim was to compare the effectiveness of lead and lightweight aprons in shielding from 99m-Technetium ( 99m Tc) gamma rays. The doses received from a scattering phantom to the entrance, 9 cm depth and exit of a phantom were measured with LiF:Mg, Cu, P thermoluminescent dosemeters (TLDs). Doses and spectra were assessed without no shielding, with 0.5-mm lead and lightweight aprons. The lead and lightweight aprons decreased entrance surface doses by 76 and 59%, respectively. The spectral analysis showed that the lightweight apron provided better dose reduction at energies 99m Tc labelled radiopharmaceutical. (authors)

  13. Method for evaluation of doses from ingestion of polonium, bismuth and lead as natural radioactive material(NORM)

    International Nuclear Information System (INIS)

    Pena, Vanessa; Puerta, Anselmo; Morales, Javier

    2013-01-01

    In this work was carried out an evaluation of dose from ingestion of radioactive daughters of radon (lead, bismuth and polonium), taking into account ages from three months up to adult men, using the new model of the human alimentary tract HATM and methodology of calculating doses proposed by the ICRP publication 103, which allows the estimation of dose based on the concentration of the radionuclide present in the diet or in the water of consumption

  14. Determination of internal radiation dose due to intake of polonium 210 and lead 210 via smoking

    International Nuclear Information System (INIS)

    Al-Masri, M. S.; Kharita, M.H.; Nashawati, A.; Amin, Y.; Al-Akel, B.

    2004-12-01

    In this study, 18 kind of cigarettes and five kinds of molasses consumed by Syrians were collected and analyzed for radioactivity in order to estimate the internal radiation dose caused by 210 Po and 210 Pb intake. Polonium 210 and lead 210 concentrations varied between 4 and 16.4 m Bq/cigarette, while 210 Po distribution ratios in different parts of consumed cigarette were %12, %73, %1.6 in ash, smoke and filter, respectively. In addition, annual intake of 210 Po by a main smoker was varied between 4.4 and 18 Bq/year assuming that the main smoker breathes about 15% of the total 210 Po present in tobacco. Using the values of the annual intake, annual equivalent radiation dose caused by smoking has reached 178 μSv/year. Moreover, mean concentration of 210 Po in nonsmokers and smokers bloods has reached 130 and 97 mBq/l, respectively, while the mean value of 210 Po concentration was relatively higher and reached 176 and 155 mBq/l in smokers and non smoker bloods, respectively (Authors)

  15. Relation between treatment efficacy and cumulative dose of alpha interferon in chronic hepatitis B. European Concerted Action on Viral Hepatitis (Eurohep)

    DEFF Research Database (Denmark)

    Krogsgaard, K; Christensen, E; Bindslev, N

    1996-01-01

    Alpha interferon (IFN) is an established treatment of chronic hepatitis B. The effect has been shown to be dose related, recommended dose regimens being associated with a doubling of the spontaneous, baseline HBeAg to anti-HBe seroconversion rate. However, the efficacy of IFN treatment in relation...

  16. SU-C-207A-07: Cumulative 18F-FDG Uptake Histogram Relative to Radiation Dose Volume Histogram of Lung After IMRT Or PSPT and Their Association with Radiation Pneumonitis

    International Nuclear Information System (INIS)

    Shusharina, N; Choi, N; Bortfeld, T; Liao, Z; Mohan, R

    2016-01-01

    Purpose: To determine whether the difference in cumulative 18F-FDG uptake histogram of lung treated with either IMRT or PSPT is associated with radiation pneumonitis (RP) in patients with inoperable stage II and III NSCLC. Methods: We analyzed 24 patients from a prospective randomized trial to compare IMRT (n=12) with vs. PSPT (n=12) for inoperable NSCLC. All patients underwent PET-CT imaging between 35 and 88 days post-therapy. Post-treatment PET-CT was aligned with planning 4D CT to establish a voxel-to-voxel correspondence between post-treatment PET and planning dose images. 18F-FDG uptake as a function of radiation dose to normal lung was obtained for each patient. Distribution of the standard uptake value (SUV) was analyzed using a volume histogram method. The image quantitative characteristics and DVH measures were correlated with clinical symptoms of pneumonitis. Results: Patients with RP were present in both groups: 5 in the IMRT and 6 in the PSPT. The analysis of cumulative SUV histograms showed significantly higher relative volumes of the normal lung having higher SUV uptake in the PSPT patients for both symptomatic and asymptomatic cases (VSUV=2: 10% for IMRT vs 16% for proton RT and VSUV=1: 10% for IMRT vs 23% for proton RT). In addition, the SUV histograms for symptomatic cases in PSPT patients exhibited a significantly longer tail at the highest SUV. The absolute volume of the lung receiving the dose >70 Gy was larger in the PSPT patients. Conclusion: 18F-FDG uptake – radiation dose response correlates with RP in both groups of patients by means of the linear regression slope. SUV is higher for the PSPT patients for both symptomatic and asymptomatic cases. Higher uptake after PSPT patients is explained by larger volumes of the lung receiving high radiation dose.

  17. Double Dose: The cumulative effect of TV viewing at home and in preschool on children’s activity patterns and weight status

    Science.gov (United States)

    Ross, Sharon Taverno; Dowda, Marsha; Saunders, Ruth P.; Pate, Russell R.

    2015-01-01

    Little is known about how screen-based sedentary behavior at home and in preschool influences children’s health and activity patterns. The current study examined the individual and cumulative influence of TV viewing at home and in preschool on children’s physical activity (PA) and weight status. Children (n=339) attending 16 preschools in South Carolina were grouped into high and low TV groups based on parent report of children’s TV viewing at home and director report of TV use/rules in preschool. T-tests and mixed model ANOVAs examined differences in weight status and PA (min/hr) by high and low TV groups. Results revealed that children who were classified as High TV both at home and in preschool had significantly lower levels of moderate-to-vigorous PA compared with their Low TV counterparts. These findings demonstrate the importance of total environmental TV exposure on preschooler’s PA. Longitudinal and observational research to assess preschoolers’ cumulative screen-based sedentary behavior and its relationship with PA and weight status is needed. PMID:23502043

  18. Effects of lead in nestling black-crowned night-herons (Nycticorax nycticorax) experimentally dosed in the field

    Science.gov (United States)

    Golden, N.H.; Rattner, B.A.; Cohen, J.B.; Hoffman, D.J.; Ottinger, M.A.

    2000-01-01

    Lead is a known environmental toxicant, and poisoning resulting from the ingestion of lead shot has been well-documented in many species of waterfowl. However, much less is known regarding exposure and effects of free environmental lead in species of birds other than waterfowl. In an attempt to evaluate toxicity of lead to herons and to determine the usefulness of feathers as a non-invasive exposure-monitoring tool, black-crowned night-heron nestlings were dosed with lead to determine its distribution among tissues, and its effects on biochemical biomarkers, growth, and survival. Five-day-old heron nestlings (one per nest) at Chincoteague Bay, Virginia were given a single intra-peritoneal injection of dosing vehicle (control; N=7) or one of three lead solutions (as lead nitrate) (10, 50, or 250 mg/kg body weight of nestling; N=7 per dose) chosen to represent levels below, at, and above those found in moderately-polluted environments. All nestlings treated with lead exhibited dose-dependent inhibition of delta-aminolevulinic acid dehydratase (ALAD) activity compared to controls, and nestlings treated with the highest concentration showed a reduced carcass weight compared to controls. Of several measures of oxidative stress that were analyzed, significant differences were found between low- and high-dosed nestlings in hepatic total thiol and protein-bound sulfhydryl concentrations. No differences in survival were detected between dosed nestlings, controls, or uninjected siblings. Lead concentrations in several matrices, including feathers, are being determined to assess distribution among tissues and will also be examined for relationships with measures of effect.

  19. Dose dependent transfer of 203lead to milk and tissue uptake in suckling offspring studied in rats and mice

    International Nuclear Information System (INIS)

    Palminger Hallen, I.; Oskarsson, A.

    1993-01-01

    The dose-dependent transfer of 203 Pb to milk and uptake in suckling rats and mice during a three-day nursing period was studied. On day 14 of lactation, the dams were administered a single intravenous dose of lead, labelled with 203 Pb, in four or five doses from 0.0005 to 2.0 mg Pb/kg b.wt. There was a linear relationship between Pb levels in plasma and milk of both species. The Pb milk: plasma ratios at 24 hr after administration were 119 and 89 in mice and rats, respectively. At 72 hr the Pb milk: plasma ratio had decreased to 72 in mice and 35 in rats. The tissue levels of lead in the suckling rats and mice were also linearly correlated with lead concentration in milk at 72 hr, showing that milk could be used as an indicator of lead exposure to the suckling offspring. It is concluded that lead is transported into rat and mouse milk to a very high extent and the excretion into milk is more efficient in mice than in rats. On the other hand, rat pups had higher lead levels in tissues than mice pups, which might be due to a higher bioavailability and/or a lower excretion of lead in rat pups. Thus, lead in breast milk could be used as a biological indicator of lead exposure in the mother as well as in the suckling offspring. (au) (38 refs.)

  20. Experimental determination of foetal doses received during conventional X rays explorations of troncus. Influence of the lead apron

    International Nuclear Information System (INIS)

    Pifarre, X.; Brualla, L.; Ruiz, J.; Escalada, C.; Planes, D.; Paredes, M.C.

    2001-01-01

    The aim of this paper is to assess the real doses received by pregnant women during some X rays conventional explorations of thorax and abdomen. The procedure that has been used is the measurement of doses by the use of thermoluminescent dosimeters located on the uterus position of a Random Phantom, and simulating different conventional X rays explorations. The results of such measurements are compared with other data published in ICRP 34, which were our reference. We have obtained smaller doses with the measurements than those derived from ICRP 34. The causes of these differences are analysed. The influence of the use of lead apron to protect abdomen during thorax examination is also analysed, computing the real value of this protection. We conclude that it seems interesting to obtain measurements of theses doses with our own equipment and techniques, because it offers a more realistic approximation to real doses received by patients. (author)

  1. Cumulative Poisson Distribution Program

    Science.gov (United States)

    Bowerman, Paul N.; Scheuer, Ernest M.; Nolty, Robert

    1990-01-01

    Overflow and underflow in sums prevented. Cumulative Poisson Distribution Program, CUMPOIS, one of two computer programs that make calculations involving cumulative Poisson distributions. Both programs, CUMPOIS (NPO-17714) and NEWTPOIS (NPO-17715), used independently of one another. CUMPOIS determines cumulative Poisson distribution, used to evaluate cumulative distribution function (cdf) for gamma distributions with integer shape parameters and cdf for X (sup2) distributions with even degrees of freedom. Used by statisticians and others concerned with probabilities of independent events occurring over specific units of time, area, or volume. Written in C.

  2. Skin entrance dose with and without lead apron in digital panoramic radiography for selected sensitive body regions.

    Science.gov (United States)

    Schulze, Ralf Kurt Willy; Cremers, Catrin; Karle, Heiko; de Las Heras Gala, Hugo

    2017-05-01

    The aim of this study was to compare the dose at skin level at five significant anatomical regions for panoramic radiography devices with and without lead apron by means of a highly sensitive dosimeter. A female RANDO-phantom was exposed in five different digital panoramic radiography systems, and the dose at skin level was assessed tenfold for each measurement region by means of a highly sensitive solid-state-dosimeter. The five measurement regions selected were the thyroid, both female breasts, the gonads, and a central region in the back of the phantom. For each panoramic machine, the measurements were performed in two modes: with and without a commercial lead apron specifically designed for panoramic radiography. Reproducibility of the measurements was expressed by absolute differences and the coefficient of variation. Values between shielded and unshielded doses were pooled for each region and compared by means of the paired Wilcoxon tests (p ≤ 0.05). Reproducibility as represented by the mean CV was 22 ± 52 % (median 2.3 %) with larger variations for small dose values. Doses at skin level ranged between 0.00 μGy at the gonads and 85.39 μGy at the unshielded thyroid (mean ± SD 15 ± 24 μGy). Except for the gonads, the dose in all the other regions was significantly lower (p < 0.001) when a lead apron was applied. Unshielded doses were between 1.02-fold (thyroid) and 112-fold (at the right breast) higher than those with lead apron shielding (mean: 14-fold ± 18-fold). Although the doses were entirely very low, we observed a significant increase in dose in the radiation-sensitive female breast region when no lead apron was used. Future discussions on shielding requirements for panoramic radiography should focus on these differences in the light of the linear non-threshold (LNT) theory which is generally adopted in medical imaging.

  3. Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents

    Science.gov (United States)

    Lohrke, Jessica; Frisk, Anna-Lena; Frenzel, Thomas; Schöckel, Laura; Rosenbruch, Martin; Jost, Gregor; Lenhard, Diana Constanze; Sieber, Martin A.; Nischwitz, Volker; Küppers, Astrid; Pietsch, Hubertus

    2017-01-01

    Objectives Retrospective studies in patients with primary brain tumors or other central nervous system pathologies as well as postmortem studies have suggested that gadolinium (Gd) deposition occurs in the dentate nucleus (DN) and globus pallidus (GP) after multiple administrations of primarily linear Gd-based contrast agents (GBCAs). However, this deposition has not been associated with any adverse effects or histopathological alterations. The aim of this preclinical study was to systematically examine differences between linear and macrocyclic GBCAs in their potential to induce changes in brain and skin histology including Gd distribution in high spatial resolution. Materials and Methods Fifty male Wistar-Han rats were randomly allocated into control (saline, n = 10 rats) and 4 GBCA groups (linear GBCAs: gadodiamide and gadopentetate dimeglumine, macrocyclic GBCAs: gadobutrol and gadoteridol; n = 10 rats per group). The animals received 20 daily intravenous injections at a dose of 2.5 mmol Gd/kg body weight. Eight weeks after the last GBCA administration, the animals were killed, and the brain and skin samples were histopathologically assessed (hematoxylin and eosin; cresyl violet [Nissl]) and by immunohistochemistry. The Gd concentration in the skin, bone, brain, and skeletal muscle samples were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS, n = 4). The spatial Gd distribution in the brain and skin samples was analyzed in cryosections using laser ablation coupled with ICP-MS (LA-ICP-MS, n = 3). For the ultra-high resolution of Gd distribution, brain sections of rats injected with gadodiamide or saline (n = 1) were assessed by scanning electron microscopy coupled to energy dispersive x-ray spectroscopy and transmission electron microscopy, respectively. Results No histological changes were observed in the brain. In contrast, 4 of 10 animals in the gadodiamide group but none of the animals in other groups showed macroscopic and histological

  4. Histology and Gadolinium Distribution in the Rodent Brain After the Administration of Cumulative High Doses of Linear and Macrocyclic Gadolinium-Based Contrast Agents.

    Science.gov (United States)

    Lohrke, Jessica; Frisk, Anna-Lena; Frenzel, Thomas; Schöckel, Laura; Rosenbruch, Martin; Jost, Gregor; Lenhard, Diana Constanze; Sieber, Martin A; Nischwitz, Volker; Küppers, Astrid; Pietsch, Hubertus

    2017-06-01

    Retrospective studies in patients with primary brain tumors or other central nervous system pathologies as well as postmortem studies have suggested that gadolinium (Gd) deposition occurs in the dentate nucleus (DN) and globus pallidus (GP) after multiple administrations of primarily linear Gd-based contrast agents (GBCAs). However, this deposition has not been associated with any adverse effects or histopathological alterations. The aim of this preclinical study was to systematically examine differences between linear and macrocyclic GBCAs in their potential to induce changes in brain and skin histology including Gd distribution in high spatial resolution. Fifty male Wistar-Han rats were randomly allocated into control (saline, n = 10 rats) and 4 GBCA groups (linear GBCAs: gadodiamide and gadopentetate dimeglumine, macrocyclic GBCAs: gadobutrol and gadoteridol; n = 10 rats per group). The animals received 20 daily intravenous injections at a dose of 2.5 mmol Gd/kg body weight. Eight weeks after the last GBCA administration, the animals were killed, and the brain and skin samples were histopathologically assessed (hematoxylin and eosin; cresyl violet [Nissl]) and by immunohistochemistry. The Gd concentration in the skin, bone, brain, and skeletal muscle samples were analyzed using inductively coupled plasma mass spectroscopy (ICP-MS, n = 4). The spatial Gd distribution in the brain and skin samples was analyzed in cryosections using laser ablation coupled with ICP-MS (LA-ICP-MS, n = 3). For the ultra-high resolution of Gd distribution, brain sections of rats injected with gadodiamide or saline (n = 1) were assessed by scanning electron microscopy coupled to energy dispersive x-ray spectroscopy and transmission electron microscopy, respectively. No histological changes were observed in the brain. In contrast, 4 of 10 animals in the gadodiamide group but none of the animals in other groups showed macroscopic and histological nephrogenic systemic fibrosis-like skin

  5. Current modeling practice may lead to falsely high benchmark dose estimates.

    Science.gov (United States)

    Ringblom, Joakim; Johanson, Gunnar; Öberg, Mattias

    2014-07-01

    Benchmark dose (BMD) modeling is increasingly used as the preferred approach to define the point-of-departure for health risk assessment of chemicals. As data are inherently variable, there is always a risk to select a model that defines a lower confidence bound of the BMD (BMDL) that, contrary to expected, exceeds the true BMD. The aim of this study was to investigate how often and under what circumstances such anomalies occur under current modeling practice. Continuous data were generated from a realistic dose-effect curve by Monte Carlo simulations using four dose groups and a set of five different dose placement scenarios, group sizes between 5 and 50 animals and coefficients of variations of 5-15%. The BMD calculations were conducted using nested exponential models, as most BMD software use nested approaches. "Non-protective" BMDLs (higher than true BMD) were frequently observed, in some scenarios reaching 80%. The phenomenon was mainly related to the selection of the non-sigmoidal exponential model (Effect=a·e(b)(·dose)). In conclusion, non-sigmoid models should be used with caution as it may underestimate the risk, illustrating that awareness of the model selection process and sound identification of the point-of-departure is vital for health risk assessment. Copyright © 2014 The Authors. Published by Elsevier Inc. All rights reserved.

  6. Acute high-dose lead exposure from beverage contaminated by traditional Mexican pottery.

    Science.gov (United States)

    Matte, T D; Proops, D; Palazuelos, E; Graef, J; Hernandez Avila, M

    1994-10-15

    Screening and follow-up blood lead measurements in a 7-year-old child of a US Embassy official in Mexico City revealed an increase in blood lead concentration from 1.10 to 4.60 mumol/L in less than 4 weeks. The cause was traced to fruit punch contaminated with lead leached from traditional ceramic pottery urns. Consumption of the contaminated punch at a picnic was associated with a 20% increase in blood lead concentrations among embassy staff and dependants who were tested 6 weeks after the exposure. This episode highlights the continued health risk, even from brief exposure, posed by traditional pottery in Mexico.

  7. A new design of a lead-acrylic shield for staff dose reduction in radial and femoral access coronary catheterization

    Energy Technology Data Exchange (ETDEWEB)

    Eder, H. [Deptartment of Radiation Protection (Germany); Seidenbusch, M.C.; Treitl, M. [Muenchen Univ. Clinical Center (Germany). Inst. for Clinical Radiology; Gilligan, P. [Mater Private Hospital, Dublin (Ireland). Medical Physics

    2015-10-15

    Today's standard radiation protection during coronary angiography and percutaneous coronary interventions is the combined use of lead acrylic shields and table-mounted lower body protection. Ambient dose measurements, however, have shown that these protection devices need improvement. Using an anthropomorphic physical phantom, various scenarios were investigated with respect to personnel exposure: (a) enlarging the shield (b) adding a flexible protective curtain to the bottom side of the shield, and (c) application of radioprotective patient drapes. For visualization of the dose reduction effect, Monte Carlo simulations were performed. The flexible curtain in contact with the patient's body reduces the ambient dose rate at the operator's position by up to (87.5 % ± 7.1) compared to the situation with the bare shield. The use of both the flexible curtain and the patient drape reduces the ambient dose rate by up to (90.8 % ± 7). Similar results were achieved for the assisting personnel when they were positioned next to the operator. In addition, the enlarged shield provides better protection of the head region of tall operators. Adding a flexible protective curtain to the bottom side of the shield can protect operators from high doses, especially for body parts which are not protected by lead aprons, e.g. head, and eye lenses. This may be important with respect to lower dose limits for eye lenses in future. The protective effect in real-life working conditions is still being evaluated in an ongoing clinical study.

  8. Pretreatment with low-dose gamma irradiation enhances tolerance to the stress of cadmium and lead in Arabidopsis thaliana seedlings.

    Science.gov (United States)

    Qi, Wencai; Zhang, Liang; Wang, Lin; Xu, Hangbo; Jin, Qingsheng; Jiao, Zhen

    2015-05-01

    Heavy metals are important environmental pollutants with negative impact on plant growth and development. To investigate the physiological and molecular mechanisms of heavy metal stress mitigated by low-dose gamma irradiation, the dry seeds of Arabidopsis thaliana were exposed to a Cobalt-60 gamma source at doses ranging from 25 to 150Gy before being subjected to 75µM CdCl2 or 500µM Pb(NO3)2. Then, the growth parameters, and physiological and molecular changes were determined in response to gamma irradiation. Our results showed that 50-Gy gamma irradiation gave maximal beneficial effects on the germination index and root length in response to cadmium/lead stress in Arabidopsis seedlings. The hydrogen peroxide and malondialdehyde contents in seedlings irradiated with 50-Gy gamma rays under stress were significantly lower than those of controls. The antioxidant enzyme activities and proline levels in the irradiated seedlings were significantly increased compared with the controls. Furthermore, a transcriptional expression analysis of selected genes revealed that some components of heavy metal detoxification were stimulated by low-dose gamma irradiation under cadmium/lead stress. Our results suggest that low-dose gamma irradiation alleviates heavy metal stress, probably by modulating the physiological responses and gene expression levels related to heavy metal resistance in Arabidopsis seedlings. Copyright © 2015 Elsevier Inc. All rights reserved.

  9. Divergent Cumulative Cultural Evolution

    OpenAIRE

    Marriott, Chris; Chebib, Jobran

    2016-01-01

    Divergent cumulative cultural evolution occurs when the cultural evolutionary trajectory diverges from the biological evolutionary trajectory. We consider the conditions under which divergent cumulative cultural evolution can occur. We hypothesize that two conditions are necessary. First that genetic and cultural information are stored separately in the agent. Second cultural information must be transferred horizontally between agents of different generations. We implement a model with these ...

  10. The use of steel and lead shieldings in radiotherapy rooms and its comparison with respect to neutrons doses at patients

    International Nuclear Information System (INIS)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G.; Santos, R.F.G.

    2015-01-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H*(10) n , within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5x5cm 2 , 10x10cm 2 , 20x20cm 2 , 30x30cm 2 and 40x40cm 2 openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H*(10) n at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation.

  11. Subacute effects of low dose lead nitrate and mercury chloride exposure on kidney of rats.

    Science.gov (United States)

    Apaydın, Fatma Gökçe; Baş, Hatice; Kalender, Suna; Kalender, Yusuf

    2016-01-01

    Lead nitrate and mercury chloride are the most common heavy metal pollutants. In the present study, the effects of lead and mercury induced nephrotoxicity were studied in Wistar rats. Lead nitrate (LN, 45 mg/kg b.w/day) and mercury chloride (MC, 0.02 mg/kg b.w/day) and their combination were administered orally for 28 days. Four groups of rats were used in the study: control, LN, MC and LN plus MC groups. Serum biochemical parameters, lipid peroxidation, antioxidant enzymes and histopathological changes in kidney tissues were investigated in all treatment groups. LN and MC caused severe histopathological changes. It was shown that LN, MC and also co-treatment with LN and MC exposure induced significant increase in serum urea, uric acid and creatinine levels. There were also statistically significant changes in antioxidant enzyme activities (SOD, CAT, GPx and GST) and lipid peroxidation (MDA) in all groups except control group. In this study, we showed that MC caused more harmful effects than LN in rats. Copyright © 2015 Elsevier B.V. All rights reserved.

  12. Increasing signal intensity within the dentate nucleus and globus pallidus on unenhanced T1W magnetic resonance images in patients with relapsing-remitting multiple sclerosis: correlation with cumulative dose of a macrocyclic gadolinium-based contrast agent, gadobutrol

    Energy Technology Data Exchange (ETDEWEB)

    Stojanov, Dragan A. [University of Nis, Faculty of Medicine, Nis (Serbia); Clinical Center Nis, Center for Radiology, Nis (Serbia); Aracki-Trenkic, Aleksandra [Clinical Center Nis, Center for Radiology, Nis (Serbia); Vojinovic, Slobodan; Ljubisavljevic, Srdjan [University of Nis, Faculty of Medicine, Nis (Serbia); Clinical Center Nis, Clinic for Neurology, Nis (Serbia); Benedeto-Stojanov, Daniela [University of Nis, Faculty of Medicine, Nis (Serbia)

    2016-03-15

    To evaluate correlation between cumulative dose of gadobutrol and signal intensity (SI) within dentate nucleus and globus pallidus on unenhanced T1-weighted images in patients with relapsing-remitting multiple sclerosis (RRMS). Dentate nucleus-to-pons and globus pallidus-to-thalamus SI ratios, and renal and liver functions, were evaluated after multiple intravenous administrations of 0.1 mmol/kg gadobutrol at 27, 96-98, and 168 weeks. We compared SI ratios based on the number of administrations, total amount of gadobutrol administered, and time between injections. Globus pallidus-to-thalamus (p = 0.025) and dentate nucleus-to-pons (p < 0.001) SI ratios increased after multiple gadobutrol administrations, correlated with the number of administrations (ρ = 0.263, p = 0.046, respectively) and depended on the length of administration (p = 0.017, p = 0.037, respectively). Patients receiving gadobutrol at 27 weeks showed the greatest increase in both SI ratios (p = 0.006; p = 0.014, respectively, versus 96-98 weeks). GGT increased at the end of the study (p = 0.004). In patients with RRMS, SI within the dentate nucleus and globus pallidus increased on unenhanced T1-weighted images after multiple gadobutrol injections. Administration of the same total amount of gadobutrol over a shorter period caused greater SI increase. (orig.)

  13. Co-administration of morphine and gabapentin leads to dose dependent synergistic effects in a rat model of postoperative pain

    DEFF Research Database (Denmark)

    Papathanasiou, Theodoros; Juul, Rasmus Vestergaard; Heegaard, Anne-Marie

    2016-01-01

    dose combinations and investigate whether co-administration leads to synergistic effects in a preclinical model of postoperative pain. The pharmacodynamic effects of morphine (1, 3 and 7 mg/kg), gabapentin (10, 30 and 100 mg/kg) or their combination (9 combinations in total) were evaluated in the rat...... plantar incision model using an electronic von Frey device. The percentage of maximum possible effect (%MPE) and the area under the response curve (AUC) were used for evaluation of the antihyperalgesic effects of the drugs. Identification of synergistic interactions was based on Loewe additivity response...... surface analyses. The combination of morphine and gabapentin resulted in synergistic antihyperalgesic effects in a preclinical model of postoperative pain. The synergistic interactions were found to be dose dependent and the increase in observed response compared to the theoretical additive response...

  14. Radiation brain dose to vascular surgeons during fluoroscopically guided interventions is not effectively reduced by wearing lead equivalent surgical caps.

    Science.gov (United States)

    Kirkwood, Melissa L; Arbique, Gary M; Guild, Jeffrey B; Zeng, Katie; Xi, Yin; Rectenwald, John; Anderson, Jon A; Timaran, Carlos

    2018-03-12

    Radiation to the interventionalist's brain during fluoroscopically guided interventions (FGIs) may increase the incidence of cerebral neoplasms. Lead equivalent surgical caps claim to reduce radiation brain doses by 50% to 95%. We sought to determine the efficacy of the RADPAD (Worldwide Innovations & Technologies, Lenexa, Kan) No Brainer surgical cap (0.06 mm lead equivalent at 90 kVp) in reducing radiation dose to the surgeon's and trainee's head during FGIs and to a phantom to determine relative brain dose reductions. Optically stimulated, luminescent nanoDot detectors (Landauer, Glenwood, Ill) inside and outside of the cap at the left temporal position were used to measure cap attenuation during FGIs. To check relative brain doses, nanoDot detectors were placed in 15 positions within an anthropomorphic head phantom (ATOM model 701; CIRS, Norfolk, Va). The phantom was positioned to represent a primary operator performing femoral access. Fluorography was performed on a plastic scatter phantom at 80 kVp for an exposure of 5 Gy reference air kerma with or without the hat. For each brain location, the percentage dose reduction with the hat was calculated. Means and standard errors were calculated using a pooled linear mixed model with repeated measurements. Anatomically similar locations were combined into five groups: upper brain, upper skull, midbrain, eyes, and left temporal position. This was a prospective, single-center study that included 29 endovascular aortic aneurysm procedures. The average procedure reference air kerma was 2.6 Gy. The hat attenuation at the temporal position for the attending physician and fellow was 60% ± 20% and 33% ± 36%, respectively. The equivalent phantom measurements demonstrated an attenuation of 71% ± 2.0% (P < .0001). In the interior phantom locations, attenuation was statistically significant for the skull (6% ± 1.4%) and upper brain (7.2% ± 1.0%; P < .0001) but not for the middle brain (1.4% ± 1.0%; P = .15

  15. Evaluation of backscatter dose from internal lead shielding in clinical electron beams using EGSnrc Monte Carlo simulations.

    Science.gov (United States)

    De Vries, Rowen J; Marsh, Steven

    2015-11-08

    Internal lead shielding is utilized during superficial electron beam treatments of the head and neck, such as lip carcinoma. Methods for predicting backscattered dose include the use of empirical equations or performing physical measurements. The accuracy of these empirical equations required verification for the local electron beams. In this study, a Monte Carlo model of a Siemens Artiste linac was developed for 6, 9, 12, and 15 MeV electron beams using the EGSnrc MC package. The model was verified against physical measurements to an accuracy of better than 2% and 2mm. Multiple MC simulations of lead interfaces at different depths, corresponding to mean electron energies in the range of 0.2-14 MeV at the interfaces, were performed to calculate electron backscatter values. The simulated electron backscatter was compared with current empirical equations to ascertain their accuracy. The major finding was that the current set of backscatter equations does not accurately predict electron backscatter, particularly in the lower energies region. A new equation was derived which enables estimation of electron backscatter factor at any depth upstream from the interface for the local treatment machines. The derived equation agreed to within 1.5% of the MC simulated electron backscatter at the lead interface and upstream positions. Verification of the equation was performed by comparing to measurements of the electron backscatter factor using Gafchromic EBT2 film. These results show a mean value of 0.997 ± 0.022 to 1σ of the predicted values of electron backscatter. The new empirical equation presented can accurately estimate electron backscatter factor from lead shielding in the range of 0.2 to 14 MeV for the local linacs.

  16. High-dose biotin therapy leading to false biochemical endocrine profiles: validation of a simple method to overcome biotin interference.

    Science.gov (United States)

    Piketty, Marie-Liesse; Prie, Dominique; Sedel, Frederic; Bernard, Delphine; Hercend, Claude; Chanson, Philippe; Souberbielle, Jean-Claude

    2017-05-01

    High-dose biotin therapy is beneficial in progressive multiple sclerosis (MS) and is expected to be adopted by a large number of patients. Biotin therapy leads to analytical interference in many immunoassays that utilize streptavidin-biotin capture techniques, yielding skewed results that can mimic various endocrine disorders. We aimed at exploring this interference, to be able to remove biotin and avoid misleading results. We measured free triiodothyronine (fT3), free thyroxine (fT4), thyroid-stimulating hormone (TSH), parathyroid homrone (PTH), 25-hydroxyvitamin D (25OHD), follicle-stimulating hormone (FSH), luteinizing hormone (LH), prolactin, C-peptide, cortisol (Roche Diagnostics assays), biotin and its main metabolites (liquid chromatography tandem mass spectrometry) in 23 plasmas from MS patients and healthy volunteers receiving high-dose biotin, and in 39 biotin-unsupplemented patients, before and after a simple procedure (designated N5) designed to remove biotin by means of streptavidin-coated microparticles. We also assayed fT4, TSH and PTH in the 23 high-biotin plasmas using assays not employing streptavidin-biotin binding. The biotin concentration ranged from 31.7 to 1160 µg/L in the 23 high-biotin plasmas samples. After the N5 protocol, the biotin concentration was below the detection limit in all but two samples (8.3 and 27.6 μg/L). Most hormones results were abnormal, but normalized after N5. All results with the alternative methods were normal except two slight PTH elevations. In the 39 biotin-unsupplemented patients, the N5 protocol did not affect the results for any of the hormones, apart from an 8.4% decrease in PTH. We confirm that most streptavidin-biotin hormone immunoassays are affected by high biotin concentrations, leading to a risk of misdiagnosis. Our simple neutralization method efficiently suppresses biotin interference.

  17. Cumulative radiation exposure in children with cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Reilly, R

    2010-02-01

    This retrospective study calculated the cumulative radiation dose for children with cystic fibrosis (CF) attending a tertiary CF centre. Information on 77 children with a mean age of 9.5 years, a follow up time of 658 person years and 1757 studies including 1485 chest radiographs, 215 abdominal radiographs and 57 computed tomography (CT) scans, of which 51 were thoracic CT scans, were analysed. The average cumulative radiation dose was 6.2 (0.04-25) mSv per CF patient. Cumulative radiation dose increased with increasing age and number of CT scans and was greater in children who presented with meconium ileus. No correlation was identified between cumulative radiation dose and either lung function or patient microbiology cultures. Radiation carries a risk of malignancy and children are particularly susceptible. Every effort must be made to avoid unnecessary radiation exposure in these patients whose life expectancy is increasing.

  18. CUMBIN - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, CUMBIN, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), can be used independently of one another. CUMBIN can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CUMBIN calculates the probability that a system of n components has at least k operating if the probability that any one operating is p and the components are independent. Equivalently, this is the reliability of a k-out-of-n system having independent components with common reliability p. CUMBIN can evaluate the incomplete beta distribution for two positive integer arguments. CUMBIN can also evaluate the cumulative F distribution and the negative binomial distribution, and can determine the sample size in a test design. CUMBIN is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. The CUMBIN program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CUMBIN was developed in 1988.

  19. Cumulation of light nuclei

    International Nuclear Information System (INIS)

    Baldin, A.M.; Bondarev, V.K.; Golovanov, L.B.

    1977-01-01

    Limit fragmentation of light nuclei (deuterium, helium) bombarded with 8,6 GeV/c protons was investigated. Fragments (pions, protons and deuterons) were detected within the emission angle 50-150 deg with regard to primary protons and within the pulse range 150-180 MeV/c. By the kinematics of collision of a primary proton with a target at rest the fragments observed correspond to a target mass upto 3 GeV. Thus, the data obtained correspond to teh cumulation upto the third order

  20. Case Example of Dose Optimization Using Data From Bortezomib Dose-Finding Clinical Trials.

    Science.gov (United States)

    Lee, Shing M; Backenroth, Daniel; Cheung, Ying Kuen Ken; Hershman, Dawn L; Vulih, Diana; Anderson, Barry; Ivy, Percy; Minasian, Lori

    2016-04-20

    The current dose-finding methodology for estimating the maximum tolerated dose of investigational anticancer agents is based on the cytotoxic chemotherapy paradigm. Molecularly targeted agents (MTAs) have different toxicity profiles, which may lead to more long-lasting mild or moderate toxicities as well as to late-onset and cumulative toxicities. Several approved MTAs have been poorly tolerated during long-term administration, leading to postmarketing dose optimization studies to re-evaluate the optimal treatment dose. Using data from completed bortezomib dose-finding trials, we explore its toxicity profile, optimize its dose, and examine the appropriateness of current designs for identifying an optimal dose. We classified the toxicities captured from 481 patients in 14 bortezomib dose-finding studies conducted through the National Cancer Institute Cancer Therapy Evaluation Program, computed the incidence of late-onset toxicities, and compared the incidence of dose-limiting toxicities (DLTs) among groups of patients receiving different doses of bortezomib. A total of 13,008 toxicities were captured: 46% of patients' first DLTs and 88% of dose reductions or discontinuations of treatment because of toxicity were observed after the first cycle. Moreover, for the approved dose of 1.3 mg/m(2), the estimated cumulative incidence of DLT was > 50%, and the estimated cumulative incidence of dose reduction or treatment discontinuation because of toxicity was nearly 40%. When considering the entire course of treatment, the approved bortezomib dose exceeds the conventional ceiling DLT rate of 20% to 33%. Retrospective analysis of trial data provides an opportunity for dose optimization of MTAs. Future dose-finding studies of MTAs should take into account late-onset toxicities to ensure that a tolerable dose is identified for future efficacy and comparative trials. © 2016 by American Society of Clinical Oncology.

  1. CROSSER - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, CROSSER, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, CROSSER, CUMBIN (NPO-17555), and NEWTONP (NPO-17556), can be used independently of one another. CROSSER can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. CROSSER calculates the point at which the reliability of a k-out-of-n system equals the common reliability of the n components. It is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. The program is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. It also lists the number of iterations of Newton's method required to calculate the answer within the given error. The CROSSER program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. CROSSER was developed in 1988.

  2. Influence of a Commercial Lead Apron on Patient Skin Dose Delivered During Oral and Maxillofacial Examinations under Cone Beam Computed Tomography (CBCT).

    Science.gov (United States)

    Schulze, Ralf Kurt Willy; Sazgar, Mahssa; Karle, Heiko; de Las Heras Gala, Hugo

    2017-08-01

    The purpose of this paper is to investigate the impact of a commercial lead apron on patient skin dose delivered during maxillofacial CBCT in five critical regions by means of solid-state-dosimetry. Five anatomical regions (thyroid gland, left and right breast, gonads, back of the phantom torso) in an adult female anthropomorphic phantom were selected for dose measurement by means of the highly sensitive solid-state dosimeter QUART didoSVM. Ten repeated single exposures were assessed for each patient body region for a total of five commercial CBCT devices with and without a lead apron present. Shielded and non-shielded exposures were compared under the paired Wilcoxon test, with absolute and relative differences computed. Reproducibility was expressed as the coefficient of variation (CV) between the 10 repeated assessments. The highest doses observed at skin level were found at the thyroid (mean shielded ± SD: 450.5 ± 346.7 μGy; non-shielded: 339.2 ± 348.8 μGy, p = 0.4922). Shielding resulted in a highly significant (p < 0.001) 93% dose reduction in skin dose in the female breast region with a mean non-shielded dose of approximately 35 μGy. Dose reduction was also significantly lower for the back-region (mean: -65%, p < 0.0001) as well as for the gonad-region (mean: -98%, p < 0.0001) in the shielded situation. Reproducibility was inversely correlated to skin dose (Rspearman = -0.748, p < 0.0001) with a mean CV of 10.45% (SD: 24.53 %). Skin dose in the thyroid region of the simulated patient was relatively high and not influenced by the lead apron, which did not shield this region. Dose reduction by means of a commercial lead apron was significant in all other regions, particularly in the region of the female breast.

  3. Thyroid equivalent dose in staffs that use neck lead protector in pediatric barium meal; Dose equivalente na tireoide dos profissionais que utilizam o protetor plumbifero nos exames de seed pediatrico

    Energy Technology Data Exchange (ETDEWEB)

    Filipov, Danielle; Sauzen, Jessica; Paschuk, Sergei A., E-mail: dfilipov@utfpr.edu.br [Universidade Tecnologica Federal do Parana (UTFPR), Curitiba, PR (Brazil); Schelin, Hugo R.; Denyak, Valeriy [Instituto de Pesquisa Pele Pequeno Principe (IPPP), Curitiba, PR (Brazil); Legnani, Adriano [Hospital Pequeno Principe, Curitiba, PR (Brazil)

    2015-08-15

    The aim of this study is to estimate the thyroid equivalent dose in staffs that perform pediatric barium meal procedures and use neck lead protector. Thermoluminescent Dosimeters (TLDs) were positioned on the lead protectors, used by two professionals. After that, a solid state detector was exposed (with and without the protector above it). Therefore, it was possible to obtain both lead protectors attenuation factors. At the end, average and annual doses received by the TLDs and the thyroid (applying the attenuation factor over the dosimeters doses) were obtained. It was found that the average and annual equivalent doses in the thyroid gland are, respectively, higher than in comparative studies and within the established limits. With these data, it is concluded that the application of radiation protection optimization techniques is required. (author)

  4. Hematological findings in neotropical fish Hoplias malabaricus exposed to subchronic and dietary doses of methylmercury, inorganic lead, and tributyltin chloride

    International Nuclear Information System (INIS)

    Oliveira Ribeiro, C.A.; Filipak Neto, F.; Mela, M.; Silva, P.H.; Randi, M.A.F.; Rabitto, I.S.; Alves Costa, J.R.M.; Pelletier, E.

    2006-01-01

    Hematological indices are gaining general acceptance as valuable tools in monitoring various aspects the health of fish exposed to contaminants. In this work some effects of methyl mercury (MeHg), inorganic lead (Pb 2+ ), and tributyltin (TBT) in a tropical fish species were evaluated by hematological methods after a trophic exposition at a subchronic level. Forty-two mature individuals of the freshwater top predator fish Hoplias malabaricus were exposed to trophic doses (each 5 days) of MeHg (0.075 μg g -1 ), Pb 2+ (21 μg g -1 ), and TBT (0.3 μg g -1 ) using young fish Astyanax sp. as prey vehicle. After 14 successive doses over 70 days, blood was sampled from exposed and control groups to evaluate hematological effects of metals on erythrocytes, total leukocytes and differential leukocytes counts, hematocrit, hemoglobin concentration, and red blood cell indices mean corpuscular volume (MCV), mean corpuscular hemoglobin (MCH), and mean corpuscular hemoglobin concentration (MCHC). Transmission electron microscopy and image analysis of erythrocytes were also used to investigate some morphometric parameters. Results show no significant effects in MCH and MCHC for all tested metals, but differences were found in erythrocytes, hemoglobin, hematocrit, MCV, and white blood cells counts. The number of leukocytes was increased in the presence of MeHg, suggesting effects on the immune system. Also the MCV increased in individuals exposed to MeHg. No ultrastructural damages were observed in red blood cells but the image analysis using light microscopy revealed differences in area, elongation, and roundness of erythrocytes from individuals exposed to Pb 2+ and TBT but not in the group exposed to MeHg. The present work shows that changes in hematological and blood indices could highlight some barely detectable metal effects in fish after laboratory exposure to contaminated food, but their application in field biomonitoring using H. malabaricus will need more detailed

  5. Cumulative environmental effects. Summary

    International Nuclear Information System (INIS)

    2012-01-01

    This report presents a compilation of knowledge about the state of the environment and human activity in the Norwegian part of the North Sea and Skagerrak. The report gives an overview of pressures and impacts on the environment from normal activity and in the event of accidents. This is used to assess the cumulative environmental effects, which factors have most impact and where the impacts are greatest, and to indicate which problems are expected to be most serious in the future. The report is intended to provide relevant information that can be used in the management of the marine area in the future. It also provides input for the identification of environmental targets and management measures for the North Sea and Skagerrak.(Author)

  6. Cumulative environmental effects. Summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    This report presents a compilation of knowledge about the state of the environment and human activity in the Norwegian part of the North Sea and Skagerrak. The report gives an overview of pressures and impacts on the environment from normal activity and in the event of accidents. This is used to assess the cumulative environmental effects, which factors have most impact and where the impacts are greatest, and to indicate which problems are expected to be most serious in the future. The report is intended to provide relevant information that can be used in the management of the marine area in the future. It also provides input for the identification of environmental targets and management measures for the North Sea and Skagerrak.(Author)

  7. NEWTONP - CUMULATIVE BINOMIAL PROGRAMS

    Science.gov (United States)

    Bowerman, P. N.

    1994-01-01

    The cumulative binomial program, NEWTONP, is one of a set of three programs which calculate cumulative binomial probability distributions for arbitrary inputs. The three programs, NEWTONP, CUMBIN (NPO-17555), and CROSSER (NPO-17557), can be used independently of one another. NEWTONP can be used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. The program has been used for reliability/availability calculations. NEWTONP calculates the probably p required to yield a given system reliability V for a k-out-of-n system. It can also be used to determine the Clopper-Pearson confidence limits (either one-sided or two-sided) for the parameter p of a Bernoulli distribution. NEWTONP can determine Bayesian probability limits for a proportion (if the beta prior has positive integer parameters). It can determine the percentiles of incomplete beta distributions with positive integer parameters. It can also determine the percentiles of F distributions and the midian plotting positions in probability plotting. NEWTONP is designed to work well with all integer values 0 < k <= n. To run the program, the user simply runs the executable version and inputs the information requested by the program. NEWTONP is not designed to weed out incorrect inputs, so the user must take care to make sure the inputs are correct. Once all input has been entered, the program calculates and lists the result. It also lists the number of iterations of Newton's method required to calculate the answer within the given error. The NEWTONP program is written in C. It was developed on an IBM AT with a numeric co-processor using Microsoft C 5.0. Because the source code is written using standard C structures and functions, it should compile correctly with most C compilers. The program format is interactive. It has been implemented under DOS 3.2 and has a memory requirement of 26K. NEWTONP was developed in 1988.

  8. Polonium 210 and lead 210 in Syrian sea and lake fish and the dose due to their intake

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Mamish, S.; Budeir, Y.; Nashwaty, A.

    1998-09-01

    Edible part of 36 types of sea fish collected from local market (Lattakia, Tartus, Banias) and seven types of river fish (Euphrate river and Mzerib lake) have been analyzed for 210 Po and 210 Pb. Results of analysis have shown that 210 Po and 210 Pb concentrations in sea fish varied between 0.27 and 27.48 Bq/kg and between 0.05 and 0.38 Bq/kg, respectively while for river fish concentrations were relatively low and varied between 0.61 and 3.08 Bq/kg for 210 Po and between 0.04 and 0.10 Bq/kg for 210 Pb. In addition, the Syrian adults daily intakes of 210 Po and 210 Pb have been estimated and found to be 6.0 and 0.24 mBq respectively. These intakes are much less than those reported in other areas in the world. The collective dose was also determined and found to be about 5.09 man.Sv for polonium 210 and 2.93 man.Sv for lead 210 . (author)

  9. Cumulative effects of forest management activities: how might they occur?

    Science.gov (United States)

    R. M. Rice; R. B. Thomas

    1985-01-01

    Concerns are often voiced about possible environmental damage as the result of the cumulative sedimentation effects of logging and forest road construction. In response to these concerns, National Forests are developing procedures to reduce the possibility that their activities may lead to unacceptable cumulative effects

  10. Synchronized dynamic dose reconstruction

    International Nuclear Information System (INIS)

    Litzenberg, Dale W.; Hadley, Scott W.; Tyagi, Neelam; Balter, James M.; Ten Haken, Randall K.; Chetty, Indrin J.

    2007-01-01

    Variations in target volume position between and during treatment fractions can lead to measurable differences in the dose distribution delivered to each patient. Current methods to estimate the ongoing cumulative delivered dose distribution make idealized assumptions about individual patient motion based on average motions observed in a population of patients. In the delivery of intensity modulated radiation therapy (IMRT) with a multi-leaf collimator (MLC), errors are introduced in both the implementation and delivery processes. In addition, target motion and MLC motion can lead to dosimetric errors from interplay effects. All of these effects may be of clinical importance. Here we present a method to compute delivered dose distributions for each treatment beam and fraction, which explicitly incorporates synchronized real-time patient motion data and real-time fluence and machine configuration data. This synchronized dynamic dose reconstruction method properly accounts for the two primary classes of errors that arise from delivering IMRT with an MLC: (a) Interplay errors between target volume motion and MLC motion, and (b) Implementation errors, such as dropped segments, dose over/under shoot, faulty leaf motors, tongue-and-groove effect, rounded leaf ends, and communications delays. These reconstructed dose fractions can then be combined to produce high-quality determinations of the dose distribution actually received to date, from which individualized adaptive treatment strategies can be determined

  11. Cumulative radiation effect

    International Nuclear Information System (INIS)

    Kirk, J.; Gray, W.M.; Watson, E.R.

    1977-01-01

    In five previous papers, the concept of Cumulative Radiation Effect (CRE) has been presented as a scale of accumulative sub-tolerance radiation damage, with a unique value of the CRE describing a specific level of radiation effect. Simple nomographic and tabular methods for the solution of practical problems in radiotherapy are now described. An essential feature of solving a CRE problem is firstly to present it in a concise and readily appreciated form, and, to do this, nomenclature has been introduced to describe schedules and regimes as compactly as possible. Simple algebraic equations have been derived to describe the CRE achieved by multi-schedule regimes. In these equations, the equivalence conditions existing at the junctions between schedules are not explicit and the equations are based on the CREs of the constituent schedules assessed individually without reference to their context in the regime as a whole. This independent evaluation of CREs for each schedule has resulted in a considerable simplification in the calculation of complex problems. The calculations are further simplified by the use of suitable tables and nomograms, so that the mathematics involved is reduced to simple arithmetical operations which require at the most the use of a slide rule but can be done by hand. The order of procedure in the presentation and calculation of CRE problems can be summarised in an evaluation procedure sheet. The resulting simple methods for solving practical problems of any complexity on the CRE-system are demonstrated by a number of examples. (author)

  12. Maintenance hemodialysis patients have high cumulative radiation exposure.

    LENUS (Irish Health Repository)

    Kinsella, Sinead M

    2010-10-01

    Hemodialysis is associated with an increased risk of neoplasms which may result, at least in part, from exposure to ionizing radiation associated with frequent radiographic procedures. In order to estimate the average radiation exposure of those on hemodialysis, we conducted a retrospective study of 100 patients in a university-based dialysis unit followed for a median of 3.4 years. The number and type of radiological procedures were obtained from a central radiology database, and the cumulative effective radiation dose was calculated using standardized, procedure-specific radiation levels. The median annual radiation dose was 6.9 millisieverts (mSv) per patient-year. However, 14 patients had an annual cumulative effective radiation dose over 20 mSv, the upper averaged annual limit for occupational exposure. The median total cumulative effective radiation dose per patient over the study period was 21.7 mSv, in which 13 patients had a total cumulative effective radiation dose over 75 mSv, a value reported to be associated with a 7% increased risk of cancer-related mortality. Two-thirds of the total cumulative effective radiation dose was due to CT scanning. The average radiation exposure was significantly associated with the cause of end-stage renal disease, history of ischemic heart disease, transplant waitlist status, number of in-patient hospital days over follow-up, and death during the study period. These results highlight the substantial exposure to ionizing radiation in hemodialysis patients.

  13. Structural and functional changes in the gastric intramural nervous plexus in emotionally stressed rats exposed to low doses of prolonged ionizing radiation and lead

    International Nuclear Information System (INIS)

    Lapsha, V.I.; Bocharova, V.N.; Utkina, L.N.; Rolevich, I.V.

    1999-01-01

    Changes in the catecholamine content in adrenergic fibres, acethylcholinesterase activity, and in the energy metabolism enzymes lactate dehydrogenase and succinate dehydrogenase in neurons of the gastric intramural plexus during emotional stress in rats a day after combined exposure to prolonged (30 days) ionizing radiation at a total dose 1.0 Gy and 0.6 mg/kg lead were studied. A decrease in catecholamines in adrenergic fibres and acethylcholinesterase and lactate dehydrogenase activity in neurons was observed. An enhanced sensitivity of the gastric intramural plexus after the prolonged exposure to small doses of ionizing radiation and lead in conditions of emotional stress was suggested [ru

  14. Development of a stable and sensitive semiconductor detector by using a mixture of lead(II) iodide and lead monoxide for NDT radiation dose detection

    Science.gov (United States)

    Heo, Y. J.; Kim, K. T.; Han, M. J.; Moon, C. W.; Kim, J. E.; Park, J. K.; Park, S. K.

    2018-03-01

    Recently, high-energy radiation has been widely used in various industrial fields, including the medical industry, and increasing research efforts have been devoted to the development of radiation detectors to be used with high-energy radiation. In particular, nondestructive industrial applications use high-energy radiation for ships and multilayered objects for accurate inspection. Therefore, it is crucial to verify the accuracy of radiation dose measurements and evaluate the precision and reproducibility of the radiation output dose. Representative detectors currently used for detecting the dose in high-energy regions include Si diodes, diamond diodes, and ionization chambers. However, the process of preparing these detectors is complex in addition to the processes of conducting dosimetric measurements, analysis, and evaluation. Furthermore, the minimum size that can be prepared for a detector is limited. In the present study, the disadvantages of original detectors are compensated by the development of a detector made of a mixture of polycrystalline PbI2 and PbO powder, which are both excellent semiconducting materials suitable for detecting high-energy gamma rays and X-rays. The proposed detector shows characteristics of excellent reproducibility and stable signal detection in response to the changes in energy, and was analyzed for its applicability. Moreover, the detector was prepared through a simple process of particle-in-binder to gain control over the thickness and meet the specific value designated by the user. A mixture mass ratio with the highest reproducibility was determined through reproducibility testing with respect to changes in the photon energy. The proposed detector was evaluated for its detection response characteristics with respect to high-energy photon beam, in terms of dose-rate dependence, sensitivity, and linearity evaluation. In the reproducibility assessment, the detector made with 15 wt% PbO powder showed the best characteristics of 0

  15. Straightening Beta: Overdispersion of Lethal Chromosome Aberrations following Radiotherapeutic Doses Leads to Terminal Linearity in the Alpha–Beta Model

    Directory of Open Access Journals (Sweden)

    Igor Shuryak

    2017-12-01

    Full Text Available Recent technological advances allow precise radiation delivery to tumor targets. As opposed to more conventional radiotherapy—where multiple small fractions are given—in some cases, the preferred course of treatment may involve only a few (or even one large dose(s per fraction. Under these conditions, the choice of appropriate radiobiological model complicates the tasks of predicting radiotherapy outcomes and designing new treatment regimens. The most commonly used model for this purpose is the venerable linear-quadratic (LQ formalism as it applies to cell survival. However, predictions based on the LQ model are frequently at odds with data following very high acute doses. In particular, although the LQ predicts a continuously bending dose–response relationship for the logarithm of cell survival, empirical evidence over the high-dose region suggests that the survival response is instead log-linear with dose. Here, we show that the distribution of lethal chromosomal lesions among individual human cells (lymphocytes and fibroblasts exposed to gamma rays and X rays is somewhat overdispersed, compared with the Poisson distribution. Further, we show that such overdispersion affects the predicted dose response for cell survival (the fraction of cells with zero lethal lesions. This causes the dose response to approximate log-linear behavior at high doses, even when the mean number of lethal lesions per cell is well fitted by the continuously curving LQ model. Accounting for overdispersion of lethal lesions provides a novel, mechanistically based explanation for the observed shapes of cell survival dose responses that, in principle, may offer a tractable and clinically useful approach for modeling the effects of high doses per fraction.

  16. Secant cumulants and toric geometry

    NARCIS (Netherlands)

    Michalek, M.; Oeding, L.; Zwiernik, P.W.

    2012-01-01

    We study the secant line variety of the Segre product of projective spaces using special cumulant coordinates adapted for secant varieties. We show that the secant variety is covered by open normal toric varieties. We prove that in cumulant coordinates its ideal is generated by binomial quadrics. We

  17. Use of lead aprons - further considerations of estimation of doses and conditions of acute exposures of TLD badge in diagnostic x-ray institutions

    International Nuclear Information System (INIS)

    Pradhan, A.S.; Chatterjee, S.

    2003-01-01

    In the recent study the authors reported that the exposure conditions of the use of the TLD badge, whether worn under or over the lead apron could be estimated from the readout of the TLD badge used in X-ray diagnostic departments. The effectiveness of lead aprons procured from different suppliers having the same value of quoted nominal lead equivalence was found to vary severely and this indicated some limitation in the applicability of the method of evaluation of exposure conditions of the badge. The transmission factors for the lead aprons varied up to a factor of 15 for the same value of quoted nominal lead equivalence procured from three different suppliers. This is of serious consequences in radiation protection and attracts attention for quality control. An error in the estimation of the exposure conditions of the TLD badge could lead to an underestimation of doses up to 4 times using the prevalent method. The estimation of the actual doses of radiation workers in the cases of over-exposures for the situations of the use of the TLD badge over the lead apron showed that the variation in the quality of lead aprons could be wrong in the range from 1.6 to 25 times even if the kVp of the machine is exactly known. Therefore, attempt should not be made to estimate the actual doses under lead apron from the readout of the TLD badge worn over the apron, as the real values of the transmission factors of the aprons and kVp of the X-ray machine may not be available. (author)

  18. Low dose influenza virus challenge in the ferret leads to increased virus shedding and greater sensitivity to oseltamivir.

    Science.gov (United States)

    Marriott, Anthony C; Dove, Brian K; Whittaker, Catherine J; Bruce, Christine; Ryan, Kathryn A; Bean, Thomas J; Rayner, Emma; Pearson, Geoff; Taylor, Irene; Dowall, Stuart; Plank, Jenna; Newman, Edmund; Barclay, Wendy S; Dimmock, Nigel J; Easton, Andrew J; Hallis, Bassam; Silman, Nigel J; Carroll, Miles W

    2014-01-01

    Ferrets are widely used to study human influenza virus infection. Their airway physiology and cell receptor distribution makes them ideal for the analysis of pathogenesis and virus transmission, and for testing the efficacy of anti-influenza interventions and vaccines. The 2009 pandemic influenza virus (H1N1pdm09) induces mild to moderate respiratory disease in infected ferrets, following inoculation with 106 plaque-forming units (pfu) of virus. We have demonstrated that reducing the challenge dose to 102 pfu delays the onset of clinical signs by 1 day, and results in a modest reduction in clinical signs, and a less rapid nasal cavity innate immune response. There was also a delay in virus production in the upper respiratory tract, this was up to 9-fold greater and virus shedding was prolonged. Progression of infection to the lower respiratory tract was not noticeably delayed by the reduction in virus challenge. A dose of 104 pfu gave an infection that was intermediate between those of the 106 pfu and 102 pfu doses. To address the hypothesis that using a more authentic low challenge dose would facilitate a more sensitive model for antiviral efficacy, we used the well-known neuraminidase inhibitor, oseltamivir. Oseltamivir-treated and untreated ferrets were challenged with high (106 pfu) and low (102 pfu) doses of influenza H1N1pdm09 virus. The low dose treated ferrets showed significant delays in innate immune response and virus shedding, delayed onset of pathological changes in the nasal cavity, and reduced pathological changes and viral RNA load in the lung, relative to untreated ferrets. Importantly, these observations were not seen in treated animals when the high dose challenge was used. In summary, low dose challenge gives a disease that more closely parallels the disease parameters of human influenza infection, and provides an improved pre-clinical model for the assessment of influenza therapeutics, and potentially, influenza vaccines.

  19. Low dose influenza virus challenge in the ferret leads to increased virus shedding and greater sensitivity to oseltamivir.

    Directory of Open Access Journals (Sweden)

    Anthony C Marriott

    Full Text Available Ferrets are widely used to study human influenza virus infection. Their airway physiology and cell receptor distribution makes them ideal for the analysis of pathogenesis and virus transmission, and for testing the efficacy of anti-influenza interventions and vaccines. The 2009 pandemic influenza virus (H1N1pdm09 induces mild to moderate respiratory disease in infected ferrets, following inoculation with 106 plaque-forming units (pfu of virus. We have demonstrated that reducing the challenge dose to 102 pfu delays the onset of clinical signs by 1 day, and results in a modest reduction in clinical signs, and a less rapid nasal cavity innate immune response. There was also a delay in virus production in the upper respiratory tract, this was up to 9-fold greater and virus shedding was prolonged. Progression of infection to the lower respiratory tract was not noticeably delayed by the reduction in virus challenge. A dose of 104 pfu gave an infection that was intermediate between those of the 106 pfu and 102 pfu doses. To address the hypothesis that using a more authentic low challenge dose would facilitate a more sensitive model for antiviral efficacy, we used the well-known neuraminidase inhibitor, oseltamivir. Oseltamivir-treated and untreated ferrets were challenged with high (106 pfu and low (102 pfu doses of influenza H1N1pdm09 virus. The low dose treated ferrets showed significant delays in innate immune response and virus shedding, delayed onset of pathological changes in the nasal cavity, and reduced pathological changes and viral RNA load in the lung, relative to untreated ferrets. Importantly, these observations were not seen in treated animals when the high dose challenge was used. In summary, low dose challenge gives a disease that more closely parallels the disease parameters of human influenza infection, and provides an improved pre-clinical model for the assessment of influenza therapeutics, and potentially, influenza vaccines.

  20. The lead isotopic composition of dust in the vicinity of a uranium mine in northern Australia and its use for radiation dose assessment

    International Nuclear Information System (INIS)

    Bollhoefer, Andreas; Honeybun, Russell; Rosman, Kevin; Martin, Paul

    2006-01-01

    Airborne lead isotope ratios were measured via Thermal Ionisation Mass Spectrometry in samples from the vicinity of Ranger uranium mine in northern Australia. Dust deposited on leaves of Acacia spp. was washed off and analysed to gain a geographical snapshot of lead isotope ratios in the region. Aerosols were also collected on Teflon filters that were changed monthly over one seasonal cycle using a low volume diaphragm pump. Lead isotope ratios in dust deposited on leaves overestimate the relative amount of mine origin airborne lead, most likely due to a difference of the size distribution of particles collected on leaves and true aerosol size distribution. Seasonal measurements show that the annual average mine contribution to airborne lead concentrations in Jabiru East, approximately 2.5 km northwest of the mine, amounted to 13%, with distinct differences between the wet and dry season. The relative contribution of mine origin lead deposited on leaves in the dry season drops to less than 1% at a distance of 12.5 km from the mine along the major wind direction. An approach is outlined, in which lead isotope ratios are used to estimate the effective radiation dose received from the inhalation of mine origin radioactivity trapped in or on dust. Using the data from our study, this dose has been calculated to be approximately 2 μSv year -1 for people living and working in the area

  1. Polonium-210 and Lead-210 in food and tobacco products: transfer parameters and normal exposure and dose

    International Nuclear Information System (INIS)

    Watson, A.P.

    1985-01-01

    Food-chain transport of Pb-210 and Po-210 from soil to edible plant parts and from animal feed to meat and milk was evaluated from a review of literature. The degree of transfer was characterized by estimating concentration factors as well as the transfer coefficients B/sub v/, B/sub r/, f/sub m/, and f/sub f/. Global dietary intake of Pb-210 and Po-210 was also summarized, and 50-y dose estimates to target organs were calculated. The greatest estimated ingestion doses were those to populations with large dietary complements of animal protein in the form of seafood (Japan) or caribou/reindeer muscle and organ meats (Arctic Eskimos and Lapps). The origin and magnitude of inhalation exposure and dose from tobacco products were also assessed. For the majority of internal organs evaluated, the dose resulting from smoking commercially available tobacco products is comparable with or greater than the dose estimates for ingestion of naturally occurring dietary Pb-210 and Po-210. 79 refs

  2. Radiation exposure of radiologists during angiography: Dose measurements outside the lead apron; Die Strahlenexposition des Radiologen bei Angiographien: Dosismessungen ausserhalb der Bleischuerze

    Energy Technology Data Exchange (ETDEWEB)

    Fischer, H. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany); Przetak, C. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany); Teubert, G. [Landesanstalt fuer Arbeitsschutz, Duesseldorf (Germany); Ewen, K. [Landesanstalt fuer Arbeitsschutz, Duesseldorf (Germany); Moedder, U. [Inst. fuer Diagnostische Radiologie, Duesseldorf Univ. (Germany)

    1995-02-01

    The aim of this study was to provide practical information to angiographers concerning radiation exposure to body parts not covered by lead aprons. Individual doses to the neck and hands of radiologists measured in micro-Sieverts were obtained during the course of 80 angiographies of various types. The number of diagnostic and interventional procedures, which might lead to exceeding permissible doses, have been calculated. Possibilities of estimating doses during angiography by means of parameters such as screening times were examined statistically. Especially with regard to the hands, estimations of the doses are insufficient (correlation r=0.21). Radiologists who undertake much angiographic and particularly interventional work may reach exposure levels requiring protective measures in addition to lead aprons. (orig.) [Deutsch] Ziel dieser Studie ist es, dem angiographierenden Radiologen praktische Anhaltspunkte zur Einschaetzung der Strahlenexposition der nicht von der Bleischuerze abgedeckten Koerperteile zu geben. Bei 80 Angiographien aus einem breiten klinischen Spektrum wurden Einzeldosen in Mikro-Sievert an Hals und Hand des Radiologen gemessen. Fuer bestimmte Gruppen von diagnostischen und interventionellen Angiographien wurde die Anzahl der Untersuchungen hochgerechnet, die zu einer Ueberschreitung der Grenzwerte fuehren koennte. Die Moeglichkeit einer Schaetzung der Dosis anhand von Parametern der Angiographie, wie z.B. der Durchleuchtungszeit, wurde korrelationsstatistisch geprueft. Besonders fuer die Haende ist eine Schaetzung unzureichend (r=0,21). Kontinuierlich und viel angiographiende Radiologen koennen im diagnostischen, aber eher noch im interventionellen Bereich eine Groessenordnung erreichen, die Vorsichtsmassnahmen oder Zusatzmessungen ausserhalb der Bleischuerze sinnvoll erscheinen laesst. (orig.)

  3. Lead-210, bismuth-210, polonium-210. Natural activity, internal dosimetry, and dose factors for ingestion and inhalation

    International Nuclear Information System (INIS)

    Jacobi, W.

    1979-02-01

    Starting with a comprehensive review of the normal, natural activity of 210 Pb and 210 Po in the environment and in the tissues of the human body, a model of the activity and dose distributions of this nuclides in the human body is developed. Dose factors for ingestion with food and for inhalation are derived from this model, related to the intake rate unit. This 'natural exposure model' can be used for an estimation of the population exposure due to normal natural radiation as well as to man-made sourcess of these nuclides, e.g. coal-fired power plants. (orig.) [de

  4. The challenge of cumulative impacts

    Energy Technology Data Exchange (ETDEWEB)

    Masden, Elisabeth

    2011-07-01

    Full text: As governments pledge to combat climate change, wind turbines are becoming a common feature of terrestrial and marine environments. Although wind power is a renewable energy source and a means of reducing carbon emissions, there is a need to ensure that the wind farms themselves do not damage the environment. There is particular concern over the impacts of wind farms on bird populations, and with increasing numbers of wind farm proposals, the concern focuses on cumulative impacts. Individually, a wind farm, or indeed any activity/action, may have minor effects on the environment, but collectively these may be significant, potentially greater than the sum of the individual parts acting alone. Cumulative impact assessment is a legislative requirement of environmental impact assessment but such assessments are rarely adequate restricting the acquisition of basic knowledge about the cumulative impacts of wind farms on bird populations. Reasons for this are numerous but a recurring theme is the lack of clear definitions and guidance on how to perform cumulative assessments. Here we present a conceptual framework and include illustrative examples to demonstrate how the framework can be used to improve the planning and execution of cumulative impact assessments. The core concept is that explicit definitions of impacts, actions and scales of assessment are required to reduce uncertainty in the process of assessment and improve communication between stake holders. Only when it is clear what has been included within a cumulative assessment, is it possible to make comparisons between developments. Our framework requires improved legislative guidance on the actions to include in assessments, and advice on the appropriate baselines against which to assess impacts. Cumulative impacts are currently considered on restricted scales (spatial and temporal) relating to individual development assessments. We propose that benefits would be gained from elevating cumulative

  5. Conceptual models for cumulative risk assessment.

    Science.gov (United States)

    Linder, Stephen H; Sexton, Ken

    2011-12-01

    In the absence of scientific consensus on an appropriate theoretical framework, cumulative risk assessment and related research have relied on speculative conceptual models. We argue for the importance of theoretical backing for such models and discuss 3 relevant theoretical frameworks, each supporting a distinctive "family" of models. Social determinant models postulate that unequal health outcomes are caused by structural inequalities; health disparity models envision social and contextual factors acting through individual behaviors and biological mechanisms; and multiple stressor models incorporate environmental agents, emphasizing the intermediary role of these and other stressors. The conclusion is that more careful reliance on established frameworks will lead directly to improvements in characterizing cumulative risk burdens and accounting for disproportionate adverse health effects.

  6. Effects of lead administration at low doses by different routes on rat spleens. Study of response of splenic lymphocytes and tissue lysozyme

    Energy Technology Data Exchange (ETDEWEB)

    Teijon, Cesar; Olmo, Rosa; Dolores Blanco, Maria; Romero, Arturo; Maria Teijon, Jose

    2003-09-30

    The aim of this study was to evaluate the effects of low doses of lead (200 ppm of PbAc{sub 2} for 4 weeks) on rat spleens using different routes of administration. The study has been carried out at different levels: a histological evaluation has been made, and alterations of cell proliferation, B and T lymphocyte subpopulations, and CD4{sup +} and CD8{sup +} T cell subpopulations have been evaluated. Apoptosis and necrosis of lymphoid cells were also analysed. Furthermore, lysozyme activity was measured. Results indicate a large increase in spleen size when lead is administered by intraperitoneal injection, being this route in which lead causes larger modifications in all of the parameters measured. Lead administered orally causes histological modifications, such as an increase in the number of lymphocytes as well as edema. However, significant alterations in other parameters studied have not been detected. Lead administration by intraperitoneal route causes more evident histological modifications as well as an increase in the number of lymphocytes, and also induces a decrease in the percentage of B{sup +}, T{sup +} and CD4{sup +} cells, and an increase in CD8{sup +} cells. Cell death of splenic lymphocytes is not altered by lead. With regard to the immune innate response, lead behaves as an immunomodulator as can be deduced from data on lysozyme activity in tissue. Therefore, it is possible to affirm that the effect of low doses of lead depends on the route of administration. Thus, the intraperitoneal route, through which lead goes directly to the bloodstream, causes drastic effects, generating important immunological alterations.

  7. Effects of lead administration at low doses by different routes on rat spleens. Study of response of splenic lymphocytes and tissue lysozyme

    International Nuclear Information System (INIS)

    Teijon, Cesar; Olmo, Rosa; Dolores Blanco, Maria; Romero, Arturo; Maria Teijon, Jose

    2003-01-01

    The aim of this study was to evaluate the effects of low doses of lead (200 ppm of PbAc 2 for 4 weeks) on rat spleens using different routes of administration. The study has been carried out at different levels: a histological evaluation has been made, and alterations of cell proliferation, B and T lymphocyte subpopulations, and CD4 + and CD8 + T cell subpopulations have been evaluated. Apoptosis and necrosis of lymphoid cells were also analysed. Furthermore, lysozyme activity was measured. Results indicate a large increase in spleen size when lead is administered by intraperitoneal injection, being this route in which lead causes larger modifications in all of the parameters measured. Lead administered orally causes histological modifications, such as an increase in the number of lymphocytes as well as edema. However, significant alterations in other parameters studied have not been detected. Lead administration by intraperitoneal route causes more evident histological modifications as well as an increase in the number of lymphocytes, and also induces a decrease in the percentage of B + , T + and CD4 + cells, and an increase in CD8 + cells. Cell death of splenic lymphocytes is not altered by lead. With regard to the immune innate response, lead behaves as an immunomodulator as can be deduced from data on lysozyme activity in tissue. Therefore, it is possible to affirm that the effect of low doses of lead depends on the route of administration. Thus, the intraperitoneal route, through which lead goes directly to the bloodstream, causes drastic effects, generating important immunological alterations

  8. Dose from drinking water Finland

    International Nuclear Information System (INIS)

    Maekelaeinen, Ilona; Salonen, Laina; Huikuri, Pia; Arvela, Hannu

    1999-01-01

    The dose from drinking water originates almost totally from naturally occurring radionuclides in the uranium-238 series, the most important nuclide being radon-222. Second comes lead-210, and third polonium-210. The mean age-group-weighted dose received by ingestion of drinking water is 0.14 mSv per year. More than half of the total cumulative dose of 750 manSv is received by the users of private wells, forming 13% of the population. The most exposed group comprises the users of wells drilled in bedrock, who receive 320 manSv while comprising only 4% of the population. The calculated number of annual cancer incidences due to drinking water is very sensitive to the dose-conversion factors of ingested radon used, as well as to the estimated lung cancer incidences caused by radon released from water into indoor air. (au)

  9. Computed tomography dose optimisation in cystic fibrosis: A review.

    LENUS (Irish Health Repository)

    Ferris, Helena

    2016-04-28

    Cystic fibrosis (CF) is the most common autosomal recessive disease of the Caucasian population worldwide, with respiratory disease remaining the most relevant source of morbidity and mortality. Computed tomography (CT) is frequently used for monitoring disease complications and progression. Over the last fifteen years there has been a six-fold increase in the use of CT, which has lead to a growing concern in relation to cumulative radiation exposure. The challenge to the medical profession is to identify dose reduction strategies that meet acceptable image quality, but fulfil the requirements of a diagnostic quality CT. Dose-optimisation, particularly in CT, is essential as it reduces the chances of patients receiving cumulative radiation doses in excess of 100 mSv, a dose deemed significant by the United Nations Scientific Committee on the Effects of Atomic Radiation. This review article explores the current trends in imaging in CF with particular emphasis on new developments in dose optimisation.

  10. A low-protein diet combined with low-dose endotoxin leads to changes in glucose homeostasis in weanling rats

    NARCIS (Netherlands)

    Bandsma, Robert H. J.; Ackerley, Cameron; Koulajian, Khajag; Zhang, Ling; van Zutphen, Tim; van Dijk, Theo H.; Xiao, Changting; Giacca, Adria; Lewis, Gary F.

    2015-01-01

    Severe malnutrition is a leading cause of global childhood mortality, and infection and hypoglycemia or hyperglycemia are commonly present. The etiology behind the changes in glucose homeostasis is poorly understood. Here, we generated an animal model of severe malnutrition with and without

  11. Dexamethasone hepatic induction in rats subsequently treated with high dose buprenorphine does not lead to respiratory depression

    International Nuclear Information System (INIS)

    Hreiche, Raymond; Megarbane, Bruno; Pirnay, Stephane; Borron, Stephen W.; Monier, Claire; Risede, Patricia; Milan, Nathalie; Descatoire, Veronique; Pessayre, Dominique; Baud, Frederic J.

    2006-01-01

    In humans, asphyxic deaths and severe poisonings have been attributed to high-dosage buprenorphine, a maintenance therapy for heroin addiction. However, in rats, intravenous buprenorphine at doses up to 90 mg kg -1 was not associated with significant effects on arterial blood gases. In contrast, norbuprenorphine, the buprenorphine major cytochrome P450 (CYP) 3A-derived metabolite, is a potent respiratory depressant. Thus, our aim was to study the consequences of CYP3A induction on buprenorphine-associated effects on resting ventilation in rats. We investigated the effects on ventilation of 30 mg kg -1 buprenorphine alone or following cytochrome P450 (CYP) 3A induction with dexamethasone, using whole body plethysmography (N = 24) and arterial blood gases (N = 12). Randomized animals in 4 groups received sequential intraperitoneal dosing with: (dexamethasone [days 1-3] + buprenorphine [day 4]), (dexamethasone solvent [days 1-3] + buprenorphine [day 4]), (dexamethasone [days 1-3] + buprenorphine solvent [day 4]), or (dexamethasone solvent [days 1-3] + buprenorphine solvent [day 4]). Buprenorphine alone caused a significant rapid and sustained increase in the inspiratory time (P -1 buprenorphine on rat ventilation. Our results suggest a limited role of drug-mediated CYP3A induction in the occurrence of buprenorphine-attributed respiratory depression in addicts

  12. Effective dose estimation from the Hp(10) value measured by film OR TL dosemeter located above the lead apron in medical diagnostic and intervention radiology

    International Nuclear Information System (INIS)

    Trousil, J.; Plichta, J.; Petrova, K.

    2001-01-01

    In medical institutions where the diagnostic and intervention radiology is examined the staff personnel doses reach for a long time the annual limit. State Office for Radiation Safety ordered the research task with a view to: (a) the influence of the dosemeter location on different parts of the body on the reliability of E value estimation by means of the value which is measured on the standard body location - left part of the chest above the lead apron. (b) the influence of the protective lead apron (neck, spectacles) with known lead equivalent on the E and H T value determination. In this contribution we present the results of this experimental study including the recommendation for the number and location on the body of dosemeters which are needed for the reliable estimation of E value. (authors)

  13. Online Scheduling in Manufacturing A Cumulative Delay Approach

    CERN Document Server

    Suwa, Haruhiko

    2013-01-01

    Online scheduling is recognized as the crucial decision-making process of production control at a phase of “being in production" according to the released shop floor schedule. Online scheduling can be also considered as one of key enablers to realize prompt capable-to-promise as well as available-to-promise to customers along with reducing production lead times under recent globalized competitive markets. Online Scheduling in Manufacturing introduces new approaches to online scheduling based on a concept of cumulative delay. The cumulative delay is regarded as consolidated information of uncertainties under a dynamic environment in manufacturing and can be collected constantly without much effort at any points in time during a schedule execution. In this approach, the cumulative delay of the schedule has the important role of a criterion for making a decision whether or not a schedule revision is carried out. The cumulative delay approach to trigger schedule revisions has the following capabilities for the ...

  14. The Effect of Low Dose of Lead Acetate on the Fallopian Tubes and the Role of Garlic Extract—A Histomorphic Study on Mouse

    Directory of Open Access Journals (Sweden)

    Naureen Waseem

    2015-02-01

    Full Text Available This study aimed to investigate the effect of lead acetate on the fallopian tube of adult mice and the possible effect of garlic extract in a Laboratory Based Randomized Control Trial. In this study, 30 female BALBc mice were selected and randomly divided into three groups. Ten animals were placed in each group. Group A being the control received only the laboratory diet. Group B was given lead acetate at a dose of 30 mg/kg/day. Group C was given lead acetate at 30 mg/kg/day and garlic extract at 500 mg/kg/day. All treatments were given through oral gavage tube for 60 days. The mice were sacrificed and dissected at the end of 60 days. The fallopian tubes were carefully dissected out and fixed in 10% formalin for routine histological examination. The histological findings in experimental group B showed increase in epithelial height, whereas no such findings were observed in group A and there was slight increase in height in group C. The lead acetate affected the epithelial height in lead acetate treated group which improved when cotreated with garlic extract.

  15. Next generation of adeno-associated virus 2 vectors: Point mutations in tyrosines lead to high-efficiency transduction at lower doses

    Science.gov (United States)

    Zhong, Li; Li, Baozheng; Mah, Cathryn S.; Govindasamy, Lakshmanan; Agbandje-McKenna, Mavis; Cooper, Mario; Herzog, Roland W.; Zolotukhin, Irene; Warrington, Kenneth H.; Weigel-Van Aken, Kirsten A.; Hobbs, Jacqueline A.; Zolotukhin, Sergei; Muzyczka, Nicholas; Srivastava, Arun

    2008-01-01

    Recombinant adeno-associated virus 2 (AAV2) vectors are in use in several Phase I/II clinical trials, but relatively large vector doses are needed to achieve therapeutic benefits. Large vector doses also trigger an immune response as a significant fraction of the vectors fails to traffic efficiently to the nucleus and is targeted for degradation by the host cell proteasome machinery. We have reported that epidermal growth factor receptor protein tyrosine kinase (EGFR-PTK) signaling negatively affects transduction by AAV2 vectors by impairing nuclear transport of the vectors. We have also observed that EGFR-PTK can phosphorylate AAV2 capsids at tyrosine residues. Tyrosine-phosphorylated AAV2 vectors enter cells efficiently but fail to transduce effectively, in part because of ubiquitination of AAV capsids followed by proteasome-mediated degradation. We reasoned that mutations of the surface-exposed tyrosine residues might allow the vectors to evade phosphorylation and subsequent ubiquitination and, thus, prevent proteasome-mediated degradation. Here, we document that site-directed mutagenesis of surface-exposed tyrosine residues leads to production of vectors that transduce HeLa cells ≈10-fold more efficiently in vitro and murine hepatocytes nearly 30-fold more efficiently in vivo at a log lower vector dose. Therapeutic levels of human Factor IX (F.IX) are also produced at an ≈10-fold reduced vector dose. The increased transduction efficiency of tyrosine-mutant vectors is due to lack of capsid ubiquitination and improved intracellular trafficking to the nucleus. These studies have led to the development of AAV vectors that are capable of high-efficiency transduction at lower doses, which has important implications in their use in human gene therapy. PMID:18511559

  16. Cumulative risk, cumulative outcome: a 20-year longitudinal study.

    Directory of Open Access Journals (Sweden)

    Leslie Atkinson

    Full Text Available Cumulative risk (CR models provide some of the most robust findings in the developmental literature, predicting numerous and varied outcomes. Typically, however, these outcomes are predicted one at a time, across different samples, using concurrent designs, longitudinal designs of short duration, or retrospective designs. We predicted that a single CR index, applied within a single sample, would prospectively predict diverse outcomes, i.e., depression, intelligence, school dropout, arrest, smoking, and physical disease from childhood to adulthood. Further, we predicted that number of risk factors would predict number of adverse outcomes (cumulative outcome; CO. We also predicted that early CR (assessed at age 5/6 explains variance in CO above and beyond that explained by subsequent risk (assessed at ages 12/13 and 19/20. The sample consisted of 284 individuals, 48% of whom were diagnosed with a speech/language disorder. Cumulative risk, assessed at 5/6-, 12/13-, and 19/20-years-old, predicted aforementioned outcomes at age 25/26 in every instance. Furthermore, number of risk factors was positively associated with number of negative outcomes. Finally, early risk accounted for variance beyond that explained by later risk in the prediction of CO. We discuss these findings in terms of five criteria posed by these data, positing a "mediated net of adversity" model, suggesting that CR may increase some central integrative factor, simultaneously augmenting risk across cognitive, quality of life, psychiatric and physical health outcomes.

  17. Cumulative or delayed nephrotoxicity after cisplatin (DDP) treatment.

    Science.gov (United States)

    Pinnarò, P; Ruggeri, E M; Carlini, P; Giovannelli, M; Cognetti, F

    1986-04-30

    The present retrospective study reports data regarding renal toxicity in 115 patients (63 males, 52 females; median age, 56 years) who received cumulative doses of cisplatin (DDP) greater than or equal to 200 mg/m2. DDP was administered alone or in combination at a dose of 50-70 mg/m2 in 91 patients, and at a dose of 100 mg/m2 in 22 patients. Two patients after progression of ovarian carcinoma treated with conventional doses of DDP received 4 and 2 courses, respectively, of high-dose DDP (40 mg/m2 for 5 days) in hypertonic saline. The median number of DDP courses was 6 (range 2-14), and the median cumulative dose was 350 mg/m2 (range, 200-1200). Serum creatinine and urea nitrogen were determined before initiating the treatment and again 13-16 days after each administration. The incidence of azotemia (creatinina levels that exceeded 1.5 mg/dl) was similar before (7.8%) and after (6.1%) DDP doses of 200 mg/m2. Azotemia appears to be related to the association of DDP with other potentially nephrotoxic antineoplastic drugs (methotrexate) more than to the dose per course of DDP. Of 59 patients followed for 2 months or more after discontinuing the DDP treatment, 3 (5.1%) presented creatinine values higher than 1.5 mg/dl. The data deny that the incidence of nephrotoxicity is higher in patients receiving higher cumulative doses of DDP and confirm that increases in serum creatinine levels may occur some time after discontinuation of the drug.

  18. 78 FR 25440 - Request for Information and Citations on Methods for Cumulative Risk Assessment

    Science.gov (United States)

    2013-05-01

    ... Citations on Methods for Cumulative Risk Assessment AGENCY: Office of the Science Advisor, Environmental... influence exposures, dose-response or risk/hazard posed by environmental contaminant exposures, and methods... who wish to receive further information about submitting information on methods for cumulative risk...

  19. The Algebra of the Cumulative Percent Operation.

    Science.gov (United States)

    Berry, Andrew J.

    2002-01-01

    Discusses how to help students avoid some pervasive reasoning errors in solving cumulative percent problems. Discusses the meaning of ."%+b%." the additive inverse of ."%." and other useful applications. Emphasizes the operational aspect of the cumulative percent concept. (KHR)

  20. Adaptive strategies for cumulative cultural learning.

    Science.gov (United States)

    Ehn, Micael; Laland, Kevin

    2012-05-21

    The demographic and ecological success of our species is frequently attributed to our capacity for cumulative culture. However, it is not yet known how humans combine social and asocial learning to generate effective strategies for learning in a cumulative cultural context. Here we explore how cumulative culture influences the relative merits of various pure and conditional learning strategies, including pure asocial and social learning, critical social learning, conditional social learning and individual refiner strategies. We replicate the Rogers' paradox in the cumulative setting. However, our analysis suggests that strategies that resolved Rogers' paradox in a non-cumulative setting may not necessarily evolve in a cumulative setting, thus different strategies will optimize cumulative and non-cumulative cultural learning. Copyright © 2012 Elsevier Ltd. All rights reserved.

  1. 32 CFR 651.16 - Cumulative impacts.

    Science.gov (United States)

    2010-07-01

    ... 32 National Defense 4 2010-07-01 2010-07-01 true Cumulative impacts. 651.16 Section 651.16... § 651.16 Cumulative impacts. (a) NEPA analyses must assess cumulative effects, which are the impact on the environment resulting from the incremental impact of the action when added to other past, present...

  2. Method for evaluation of doses from ingestion of polonium, bismuth and lead as natural radioactive material(NORM); Metodo de evaluacion de dosis por ingestion de polonio, bismuto y plomo como materiales radiactivos naturales

    Energy Technology Data Exchange (ETDEWEB)

    Pena, Vanessa; Puerta, Anselmo; Morales, Javier, E-mail: vpenam@ullal.edu.co, E-mail: japuerta@unal.edu.co, E-mail: jmorales@unal.cdu.co [Universidad Nacional de Colombia, Medellin (Colombia). Grupo de Fisica Radiologica

    2013-07-01

    In this work was carried out an evaluation of dose from ingestion of radioactive daughters of radon (lead, bismuth and polonium), taking into account ages from three months up to adult men, using the new model of the human alimentary tract HATM and methodology of calculating doses proposed by the ICRP publication 103, which allows the estimation of dose based on the concentration of the radionuclide present in the diet or in the water of consumption.

  3. Determination of transfer factors of uranium, thorium, radium and lead from soil to agricultural product in Japan for estimating internal radiation dose through ingestion

    International Nuclear Information System (INIS)

    Sasaki, Tomozo; Tashiro, Yoshikazu; Fujinaga, Hideshi; Ishii, Tomoaki; Gunji, Yasuyoshi

    2002-01-01

    The transfer factors (TFs) of uranium (U), thorium (Th), radium (Ra) and lead (Pb) from soil to agricultural products were determined in order to estimate the internal radiation dose to the human body through ingestion. Samples of rice, potato, onion, cabbage, mandarin orange, spinach, apple and soil were collected from various districts in Japan. After appropriate pretreatment of the samples, concentrations in the sample solutions were measured by Inductively coupled plasma-mass spectrometry (ICP-MS) (for U, Th and Pb) and liquid scintillation counter (for Ra). It was recognized that TFs were 4.9 x 10 -6 (apple) and 3.6 x 10 -4 (spinach) for U, 2.8 x 10 -6 (apple) and 2.3 x 10 -4 (spinach) for Th, and 4.0 x 10 -3 (hulled rice), 7.0 x 10 -5 (onion) and 5.0 x 10 -3 (hulled rice) for Pb. The TF of Ra, however, was not determined due to detection limitations. TF values obtained in the present study range from the same order of magnitude to 1/100 compared to the data in Technical Report Series No.364 (TRS364) as reported by IAEA. It was revealed that the internal radiation dose caused by the intake of uranium series radioactive nuclides through agricultural food ingestion was 16 μSv/y, where Pb was the most contributory nuclide. (author)

  4. A paradox of cumulative culture.

    Science.gov (United States)

    Kobayashi, Yutaka; Wakano, Joe Yuichiro; Ohtsuki, Hisashi

    2015-08-21

    Culture can grow cumulatively if socially learnt behaviors are improved by individual learning before being passed on to the next generation. Previous authors showed that this kind of learning strategy is unlikely to be evolutionarily stable in the presence of a trade-off between learning and reproduction. This is because culture is a public good that is freely exploited by any member of the population in their model (cultural social dilemma). In this paper, we investigate the effect of vertical transmission (transmission from parents to offspring), which decreases the publicness of culture, on the evolution of cumulative culture in both infinite and finite population models. In the infinite population model, we confirm that culture accumulates largely as long as transmission is purely vertical. It turns out, however, that introduction of even slight oblique transmission drastically reduces the equilibrium level of culture. Even more surprisingly, if the population size is finite, culture hardly accumulates even under purely vertical transmission. This occurs because stochastic extinction due to random genetic drift prevents a learning strategy from accumulating enough culture. Overall, our theoretical results suggest that introducing vertical transmission alone does not really help solve the cultural social dilemma problem. Copyright © 2015 Elsevier Ltd. All rights reserved.

  5. Integration of the predictions of two models with dose measurements in a case study of children exposed to the emissions of a lead smelter

    Energy Technology Data Exchange (ETDEWEB)

    Bonnard, R.; McKone, T.E.

    2009-03-01

    The predictions of two source-to-dose models are systematically evaluated with observed data collected in a village polluted by a currently operating secondary lead smelter. Both models were built up from several sub-models linked together and run using Monte-Carlo simulation, to calculate the distribution children's blood lead levels attributable to the emissions from the facility. The first model system is composed of the CalTOX model linked to a recoded version of the IEUBK model. This system provides the distribution of the media-specific lead concentrations (air, soil, fruit, vegetables and blood) in the whole area investigated. The second model consists of a statistical model to estimate the lead deposition on the ground, a modified version of the model HHRAP and the same recoded version of the IEUBK model. This system provides an estimate of the concentration of exposure of specific individuals living in the study area. The predictions of the first model system were improved in terms of accuracy and precision by performing a sensitivity analysis and using field data to correct the default value provided for the leaf wet density. However, in this case study, the first model system tends to overestimate the exposure due to exposed vegetables. The second model was tested for nine children with contrasting exposure conditions. It managed to capture the blood levels for eight of them. In the last case, the exposure of the child by pathways not considered in the model may explain the failure of the model. The interest of this integrated model is to provide outputs with lower variance than the first model system, but at the moment further tests are necessary to conclude about its accuracy.

  6. Fetal dose evaluation during breast cancer radiotherapy

    International Nuclear Information System (INIS)

    Antypas, Christos; Sandilos, Panagiotis; Kouvaris, John; Balafouta, Ersi; Karinou, Eleftheria; Kollaros, Nikos; Vlahos, Lambros

    1998-01-01

    Purpose: The aim of the work was to estimate the radiation dose delivered to the fetus in a pregnant patient irradiated for breast cancer. Methods and Materials: A 45-year woman was treated for left breast cancer using a 6 MV photon beam with two isocentric opposing tangential unwedged fields. Daily dose was 2.3 Gy at 95% isodose line given by two fields/day, 5 days/week. A total dose of 46 Gy was given in 20 fractions over a 4-week period. Pregnancy confirmed during the second therapeutic week. Treatment lasted between the second and sixth gestation week. Radiation dose to fetus was estimated from in vivo and phantom measurements using thermoluminescence dosimeters and an ionization chamber. In vivo measurements were performed by inserting either a catheter with TL dosimeters or ionization chamber into the patient's rectum. Phantom measurements were performed by simulating the treatment conditions on an anthropomorphic phantom. Results: TLD measurements (in vivo and phantom) revealed fetal dose to be 0.085% of the tumor dose, corresponding to a cumulative fetal dose of 3.9 cGy for the entire treatment of 46 Gy. Chamber measurements (in vivo and phantom) revealed a fetal dose less than the TLD result: 0.079 and 0.083% of the tumor dose corresponding to cumulative fetal dose of 3.6 cGy and 3.8 cGy for in vivo and phantom measurement, respectively. Conclusions: It was concluded that the cumulative dose delivered to the unshielded fetus was 3.9 cGy for a 46 Gy total tumor dose. The estimated fetal dose is low compared to the total tumor dose given due to the early stage of pregnancy, the large distance between fundus-radiation field, and the fact that no wedges and/or lead blocks were used. No deterministic biological effects of radiation on the live-born embryo are expected. The lifetime risk for radiation-induced fatal cancer is higher than the normal incidence, but is considered as inconsequential

  7. Cumulative Trauma Among Mayas Living in Southeast Florida.

    Science.gov (United States)

    Millender, Eugenia I; Lowe, John

    2017-06-01

    Mayas, having experienced genocide, exile, and severe poverty, are at high risk for the consequences of cumulative trauma that continually resurfaces through current fear of an uncertain future. Little is known about the mental health and alcohol use status of this population. This correlational study explored t/he relationship of cumulative trauma as it relates to social determinants of health (years in the United States, education, health insurance status, marital status, and employment), psychological health (depression symptoms), and health behaviors (alcohol use) of 102 Guatemalan Mayas living in Southeast Florida. The results of this study indicated that, as specific social determinants of health and cumulative trauma increased, depression symptoms (particularly among women) and the risk for harmful alcohol use (particularly among men) increased. Identifying risk factors at an early stage before serious disease or problems are manifest provides room for early screening leading to early identification, early treatment, and better outcomes.

  8. Cumulative and antagonistic effects of a mixture of the antiandrogens vinclozolin and iprodione in the pubertal male rat.

    Science.gov (United States)

    Blystone, Chad R; Lambright, Christy S; Cardon, Mary C; Furr, Johnathan; Rider, Cynthia V; Hartig, Phillip C; Wilson, Vickie S; Gray, Leon E

    2009-09-01

    Vinclozolin and iprodione are dicarboximide fungicides that display antiandrogenic effects in the male rat, which suggests that a mixture would lead to cumulative effects on androgen-sensitive end points. Iprodione is a steroid synthesis inhibitor, but androgen receptor antagonist activity, which is displayed by vinclozolin, has not been fully evaluated. Here, we demonstrate that iprodione binds to the human androgen receptor (IC(50) = 86.0 microM), reduces androgen-dependent gene expression, and reduces androgen-sensitive tissue weights in castrated male rats (Hershberger assay). Since vinclozolin and iprodione affect common targets in the pubertal male rat, we tested the hypothesis that a mixture would have cumulative antiandrogenic effects. An iprodione dose, that does not significantly affect androgen-dependent morphological end points, was combined with vinclozolin doses (2 x 5 factorial design). Sprague-Dawley rats were dosed by gavage with vinclozolin at 0, 10, 30, 60, and 100 mg/kg/day with and without 50 mg iprodione/kg/day from postnatal day (PND) 23 to 55-57 (n = 8 per group). The age at puberty (preputial separation [PPS]), organ weights, serum hormones, and ex vivo testis steroid hormone production were measured. Vinclozolin delayed PPS, reduced androgen-sensitive organ weights, and increased serum testosterone. The addition of iprodione enhanced the vinclozolin inhibition of PPS (PND 47.5 vs.49.1; two-way ANOVA: iprodione main effect p = 0.0002). The dose response for several reproductive and nonreproductive organ weights was affected in a cumulative manner. In contrast, iprodione antagonized the vinclozolin-induced increase in serum testosterone. These results demonstrate that these fungicides interact on common targets in a tissue-specific manner when coadministered to the pubertal male rat.

  9. Early-life lead exposure results in dose- and sex-specific effects on weight and epigenetic gene regulation in weanling mice

    Science.gov (United States)

    Faulk, Christopher; Barks, Amanda; Liu, Kevin; Goodrich, Jaclyn M; Dolinoy, Dana C

    2013-01-01

    Aims Epidemiological and animal data suggest that the development of adult chronic conditions is influenced by early-life exposure-induced changes to the epigenome. This study investigates the effects of perinatal lead (Pb) exposure on DNA methylation and bodyweight in weanling mice. Materials & methods Viable yellow agouti (Avy) mouse dams were exposed to 0, 2.1, 16 and 32 ppm Pb acetate before conception through weaning. Epigenetic effects were evaluated by scoring coat color of Avy/a offspring and quantitative bisulfite sequencing of two retrotransposon-driven (Avy and CDK5 activator-binding protein intracisternal A particle element) and two imprinted (Igf2 and Igf2r) loci in tail DNA. Results Maternal blood Pb levels were below the limit of detection in controls, and 4.1, 25.1 and 32.1 μg/dl for each dose, respectively. Pb exposure was associated with a trend of increased wean bodyweight in males (p = 0.03) and altered coat color in Avy/a offspring. DNA methylation at Avy and the CDK5 activator-binding protein intracisternal A-particle element was significantly different from controls following a cubic trend (p = 0.04; p = 0.01), with male-specific effects at the Avy locus. Imprinted genes did not shift in methylation across exposures. Conclusion Dose- and sex-specific responses in bodyweight and DNA methylation indicate that Pb acts on the epigenome in a locus-specific fashion, dependent on the genomic feature hosting the CpG site of interest, and that sex is a factor in epigenetic response. PMID:24059796

  10. Cumulative trauma disorders: A review.

    Science.gov (United States)

    Iqbal, Zaheen A; Alghadir, Ahmad H

    2017-08-03

    Cumulative trauma disorder (CTD) is a term for various injuries of the musculoskeletal and nervous systems that are caused by repetitive tasks, forceful exertions, vibrations, mechanical compression or sustained postures. Although there are many studies citing incidence of CTDs, there are fewer articles about its etiology, pathology and management. The aim of our study was to discuss the etiology, pathogenesis, prevention and management of CTDs. A literature search was performed using various electronic databases. The search was limited to articles in English language pertaining to randomized clinical trials, cohort studies and systematic reviews of CTDs. A total of 180 papers were identified to be relevant published since 1959. Out of these, 125 papers reported about its incidence and 50 about its conservative treatment. Workplace environment, same task repeatability and little variability, decreased time for rest, increase in expectations are major factors for developing CTDs. Prevention of its etiology and early diagnosis can be the best to decrease its incidence and severity. For effective management of CTDs, its treatment should be divided into Primordial, Primary, Secondary and Tertiary prevention.

  11. Complete cumulative index (1963-1983)

    International Nuclear Information System (INIS)

    1983-01-01

    This complete cumulative index covers all regular and special issues and supplements published by Atomic Energy Review (AER) during its lifetime (1963-1983). The complete cumulative index consists of six Indexes: the Index of Abstracts, the Subject Index, the Title Index, the Author Index, the Country Index and the Table of Elements Index. The complete cumulative index supersedes the Cumulative Indexes for Volumes 1-7: 1963-1969 (1970), and for Volumes 1-10: 1963-1972 (1972); this Index also finalizes Atomic Energy Review, the publication of which has recently been terminated by the IAEA

  12. Polonium 2 sup 1 sup 0 and lead 2 sup 1 sup 0 in Syrian sea and river fish and radiation dose due to their consumption

    International Nuclear Information System (INIS)

    Al-Masri, M.S.; Mamish, S.; Budier, Y.; Nashwati, A.

    1999-01-01

    Edible part of 36 types of sea fish collected from local market (Lattakia, Tartus, Banias) and seven types of river fish (Al-Furat river and Mzerib lake) have been analyzed for 210 Po and 210 Pb. Results of analysis have shown that 210 Po and 210 Pb concentrations in sea fish varied between 0.27 and 27.48 Bq/kg and between 0.05 and 0.38 Bq/kg, respectively while for river fish concentrations were relatively low and varied between 0.61 and 3.08 Bq/kg for 210 Po and between 0.04 and 0.10 Bq/kg for 210 Pb. In addition, the Syrian adults daily intakes of 210 Po and 210 Pb have been estimated and found to be 6.0 and 0.24 mBq respectively. These intakes are much less than those reported in other areas in the world. The collective dose was also determined and found to be about 5.09 man.sv for polonium 210 and 2.93 man.sv for lead 210 . (author)

  13. Individualized versus standard FSH dosing in women starting IVF/ICSI : An RCT. Part 2: The predicted hyper responder

    NARCIS (Netherlands)

    Oudshoorn, Simone C.; Van Tilborg, Theodora C.; Eijkemans, Marinus J. C.; Oosterhuis, G. Jur E.; Friederich, Jaap; van Hooff, Marcel H. A.; van Santbrink, Evert J. P.; Brinkhuis, Egbert A.; Smeenk, Jesper M. J.; Kwee, Janet; de Koning, Corry H.; Groen, Henk; Lambalk, Cornelis B.; Mol, Ben Willem J.; Broekmans, Frank J. M.; Torrance, Helen L.

    2017-01-01

    STUDY QUESTION: Does a reduced FSH dose in women with a predicted hyper response, apparent from a high antral follicle count (AFC), who are scheduled for IVF/ICSI lead to a different outcome with respect to cumulative live birth rate and safety? SUMMARY ANSWER: Although in women with a predicted

  14. Individualized versus standard FSH dosing in women starting IVF/ICSI: An RCT. Part 2: The predicted hyper responder

    OpenAIRE

    Oudshoorn, Simone C.; Van Tilborg, Theodora C.; Eijkemans, Marinus J. C.; Oosterhuis, G. Jur E.; Friederich, Jaap; van Hooff, Marcel H. A.; van Santbrink, Evert J. P.; Brinkhuis, Egbert A.; Smeenk, Jesper M. J.; Kwee, Janet; de Koning, Corry H.; Groen, Henk; Lambalk, Cornelis B.; Mol, Ben Willem J.; Broekmans, Frank J. M.

    2017-01-01

    STUDY QUESTION: Does a reduced FSH dose in women with a predicted hyper response, apparent from a high antral follicle count (AFC), who are scheduled for IVF/ICSI lead to a different outcome with respect to cumulative live birth rate and safety? SUMMARY ANSWER: Although in women with a predicted hyper response (AFC > 15) undergoing IVF/ICSI a reduced FSH dose (100 IU per day) results in similar cumulative live birth rates and a lower occurrence of any grade of ovarian hyperstimulation syndrom...

  15. Characterization by Monte Carlo of the dose after a glass shield lead for gamma ray; Caracterizacion por Monte Carlo de la dosis tras un blindaje de vidrio de plomo para rayos gamma

    Energy Technology Data Exchange (ETDEWEB)

    Esteve Sanchez, S.; Gil Conde, M.; Contreras Gonzalez, J. L.; Rosado, J.; Pazyi, V.

    2013-07-01

    When a gamma-ray beam crosses the border between two media characterized by atomic number very different is they produce effects on the distribution of doses near the border difficult to predict with simple models. The case of rays gamma affecting a lead glass is particularly interesting for its application to shielding of common use. interested in studying the importance of the residual dose after the shield. (Author)

  16. System-Reliability Cumulative-Binomial Program

    Science.gov (United States)

    Scheuer, Ernest M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, NEWTONP, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. NEWTONP, CUMBIN (NPO-17555), and CROSSER (NPO-17557), used independently of one another. Program finds probability required to yield given system reliability. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Program written in C.

  17. Common-Reliability Cumulative-Binomial Program

    Science.gov (United States)

    Scheuer, Ernest, M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, CROSSER, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. CROSSER, CUMBIN (NPO-17555), and NEWTONP (NPO-17556), used independently of one another. Point of equality between reliability of system and common reliability of components found. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Program written in C.

  18. Cumulative human impacts on marine predators

    DEFF Research Database (Denmark)

    Maxwell, Sara M; Hazen, Elliott L; Bograd, Steven J

    2013-01-01

    Stressors associated with human activities interact in complex ways to affect marine ecosystems, yet we lack spatially explicit assessments of cumulative impacts on ecologically and economically key components such as marine predators. Here we develop a metric of cumulative utilization and impact...

  19. Cumulative Student Loan Debt in Minnesota, 2015

    Science.gov (United States)

    Williams-Wyche, Shaun

    2016-01-01

    To better understand student debt in Minnesota, the Minnesota Office of Higher Education (the Office) gathers information on cumulative student loan debt from Minnesota degree-granting institutions. These data detail the number of students with loans by institution, the cumulative student loan debt incurred at that institution, and the percentage…

  20. Firm heterogeneity, Rules of Origin and Rules of Cumulation

    OpenAIRE

    Bombarda , Pamela; Gamberoni , Elisa

    2013-01-01

    We analyse the impact of relaxing rules of origin (ROOs) in a simple setting with heterogeneous firms that buy intermediate inputs from domestic and foreign sources. In particular, we consider the impact of switching from bilateral to diagonal cumulation when using preferences (instead of paying the MFN tariff) involving the respect of rules of origin. We find that relaxing the restrictiveness of the ROOs leads the least productive exporters to stop exporting. The empirical part confirms thes...

  1. Structure functions and particle production in the cumulative region: two different exponentials

    International Nuclear Information System (INIS)

    Braun, M.; Vechernin, V.

    1997-01-01

    In the framework of the recently proposed (QCD-based parton model for the cumulative phenomena in the interactions with nuclei two mechanisms for particle production, direct and spectator ones, are analyzed. It is shown that due to final-state interactions the leading terms of the direct mechanism contribution are cancelled and the spectator mechanism is the dominant one. It leads to a smaller slope of the cumulative particle production rates compared to the slope of the nuclear structure function in the cumulative region x ≥ 1, in agreement with the recent experimental data

  2. Effect of Low Dose Lead (Pb) Administration on Tail Immersion Test and Formalin-induced Pain in Wistar Rats: Possible Modulatory Role of Cobalt (II) Chloride.

    Science.gov (United States)

    Umar, A H; Suleiman, I; Muhammed, H

    2017-03-06

    Lead (Pb) is cheap and there is a long tradition of its use, but its toxic effects have also been recognized. There is increased public health concern regarding the hazards of low dose Pb exposure to adults and children. Studies have shown the risks for hypertension, decrements in renal function, subtle decline in cognitive function, and adverse reproductive outcome at low blood Pb level. In this study, the possible modulatory role of cobalt (II) chloride (CoCl2) on low level Pb exposure on tail immersion test and formalin induced pain was investigated. Twenty adult Wistar rats of both sexes (weight 150g to 200g) were used. The animals were divided into four groups (n = 5) and administered Pb (5mg/kg), Pb (5mg/kg) + CoCl2 (50mg/kg) and CoCl2 (50mg/kg) orally for twenty-eight days. The last group served as control and were given distilled water only. In the tail immersion test, there was no significant change in reaction time for all three groups when compared to the control. In the formalin-induced pain, pain score after five and forty-five minutes also do not show significant change for all the three groups when compared to control. This work suggested that exposure to 5mg/kg Pb for twenty-eight days do not significantly impair reaction time in tail immersion test and pain score in formalin induced pain in Wistar rats. Also, administration of 50mg/kg CoCl2 do not improve performance of the animals in the experiments.

  3. Children neglected: Where cumulative risk theory fails.

    Science.gov (United States)

    O'Hara, Mandy; Legano, Lori; Homel, Peter; Walker-Descartes, Ingrid; Rojas, Mary; Laraque, Danielle

    2015-07-01

    Neglected children, by far the majority of children maltreated, experience an environment most deficient in cognitive stimulation and language exchange. When physical abuse co-occurs with neglect, there is more stimulation through negative parent-child interaction, which may lead to better cognitive outcomes, contrary to Cumulative Risk Theory. The purpose of the current study was to assess whether children only neglected perform worse on cognitive tasks than children neglected and physically abused. Utilizing LONGSCAN archived data, 271 children only neglected and 101 children neglected and physically abused in the first four years of life were compared. The two groups were assessed at age 6 on the WPPSI-R vocabulary and block design subtests, correlates of cognitive intelligence. Regression analyses were performed, controlling for additional predictors of poor cognitive outcome, including socioeconomic variables and caregiver depression. Children only neglected scored significantly worse than children neglected and abused on the WPPSI-R vocabulary subtest (p=0.03). The groups did not differ on the block design subtest (p=0.4). This study shows that for neglected children, additional abuse may not additively accumulate risk when considering intelligence outcomes. Children experiencing only neglect may need to be referred for services that address cognitive development, with emphasis on the linguistic environment, in order to best support the developmental challenges of neglected children. Copyright © 2015 Elsevier Ltd. All rights reserved.

  4. Tests of Cumulative Prospect Theory with graphical displays of probability

    Directory of Open Access Journals (Sweden)

    Michael H. Birnbaum

    2008-10-01

    Full Text Available Recent research reported evidence that contradicts cumulative prospect theory and the priority heuristic. The same body of research also violates two editing principles of original prospect theory: cancellation (the principle that people delete any attribute that is the same in both alternatives before deciding between them and combination (the principle that people combine branches leading to the same consequence by adding their probabilities. This study was designed to replicate previous results and to test whether the violations of cumulative prospect theory might be eliminated or reduced by using formats for presentation of risky gambles in which cancellation and combination could be facilitated visually. Contrary to the idea that decision behavior contradicting cumulative prospect theory and the priority heuristic would be altered by use of these formats, however, data with two new graphical formats as well as fresh replication data continued to show the patterns of evidence that violate cumulative prospect theory, the priority heuristic, and the editing principles of combination and cancellation. Systematic violations of restricted branch independence also contradicted predictions of ``stripped'' prospect theory (subjectively weighted additive utility without the editing rules.

  5. In HFREF patients, sacubitril/valsartan, given at relatively low doses, does not lead to increased mortality or hospitalization : A retrospective cohort study.

    Science.gov (United States)

    De Vecchis, R; Ariano, C; Di Biase, G; Noutsias, M

    2018-03-08

    In heart failure with reduced left ventricular ejection fraction (HFREF) patients, the dosage of sacubitril/valsartan is modulated according to a gradual increase regimen. Nevertheless, if patients exhibit tolerability problems, a provisional reduction of the dose of sacubitril/valsartan or even its interruption are recommended. This study provides estimates of respective proportions of patients receiving minimum or intermediate doses of sacubitril/valsartan. In addition, a comparison was made to detect possible differences regarding all-cause mortality and heart failure hospitalization in patients treated with the recommended optimum dose compared to those receiving submaximum maintenance doses of sacubitril/valsartan. Patients treated with sacubitril/valsartan in addition to beta-blocker and mineralocorticoid receptor blocker were 68. Among them, 20 patients (29.4%), were identified as having clinical features that were contraindications to the administration of sacubitril/valsartan at full dose. The subsequent decision was to maintain an intermediate dose in 11 patients and to reduce the dose to the minimum level allowed, i.e., 24 mg/26 mg twice daily in nine patients. After a median follow-up of 5.25 months, no differences were found concerning the risk of all-cause death by comparing patients treated with reduced versus those subjected to target doses of sacubitril/valsartan (odds ratio [OR] = 1.666; 95% confidence interval [CI] = 0.256-10.823; p = 0.6266). Patients taking reduced doses had a similar risk of heart failure hospitalizations when compared to patients treated with the target dose (OR = 0.789; 95% CI: 0.077-8.0808; p = 1.00). During a median follow-up of 5.25 months, in the group of patients who had proven to be intolerant to the maximum dose of sacubitril/valsartan, use of reduced doses of the drug did not result in increased all-cause mortality or heart failure hospitalization compared to patients treated with

  6. Involved-nodal radiation therapy leads to lower doses to critical organs-at-risk compared to involved-field radiation therapy

    International Nuclear Information System (INIS)

    Mulvihill, David J.; McMichael, Kevin; Goyal, Sharad; Drachtman, Richard; Weiss, Aaron; Khan, Atif J.

    2014-01-01

    Background: Involved field radiotherapy (IFRT) after cytotoxic chemotherapy has become the standard of care in treating pediatric patients with Hodgkin lymphoma. However, recent interest in shrinking the treatment volume to involved node radiotherapy (INRT) may allow lower doses to critical organ structures. We dosimetrically compared IFRT and INRT treatment approaches. Methods: INRT treatment plans were retrospectively constructed from 17 consecutively treated pediatric patients identified with Hodgkin lymphoma who had been previously treated with conventional IFRT. The radiation doses delivered to organs-at-risk (OARs) with virtual INRT treatment plans based on INRT field design were then compared to the original IFRT treatment plans. Metrics for comparison included mean doses to organs and volumes of organ receiving at least 50% of the original prescription dose (V50%). A one-tailed, paired t-test was then performed to verify statistical significance at an alpha level of 0.05. Results: All organs at risk compared in this investigation (kidneys, heart, thyroid, parotids, and lungs) had significantly lower doses of radiation with INRT when compared to IFRT (p < 0.05). Furthermore, the volume of the breast receiving at least 50% of the initial prescription dose was statistically lower in the INRT plans. Conclusions: Utilizing the concept of INRT results in a reduction of radiation dose to critical organ structures in pediatric patients with Hodgkin lymphoma when compared to the more traditional method of IFRT

  7. The Relationship between Gender, Cumulative Adversities and ...

    African Journals Online (AJOL)

    The Relationship between Gender, Cumulative Adversities and Mental Health of Employees in ... CAs were measured in three forms (family adversities (CAFam), personal adversities ... Age of employees ranged between 18-65 years.

  8. Cumulative cultural learning: Development and diversity

    Science.gov (United States)

    2017-01-01

    The complexity and variability of human culture is unmatched by any other species. Humans live in culturally constructed niches filled with artifacts, skills, beliefs, and practices that have been inherited, accumulated, and modified over generations. A causal account of the complexity of human culture must explain its distinguishing characteristics: It is cumulative and highly variable within and across populations. I propose that the psychological adaptations supporting cumulative cultural transmission are universal but are sufficiently flexible to support the acquisition of highly variable behavioral repertoires. This paper describes variation in the transmission practices (teaching) and acquisition strategies (imitation) that support cumulative cultural learning in childhood. Examining flexibility and variation in caregiver socialization and children’s learning extends our understanding of evolution in living systems by providing insight into the psychological foundations of cumulative cultural transmission—the cornerstone of human cultural diversity. PMID:28739945

  9. Complexity and demographic explanations of cumulative culture

    NARCIS (Netherlands)

    Querbes, A.; Vaesen, K.; Houkes, W.N.

    2014-01-01

    Formal models have linked prehistoric and historical instances of technological change (e.g., the Upper Paleolithic transition, cultural loss in Holocene Tasmania, scientific progress since the late nineteenth century) to demographic change. According to these models, cumulation of technological

  10. Cumulative human impacts on marine predators.

    Science.gov (United States)

    Maxwell, Sara M; Hazen, Elliott L; Bograd, Steven J; Halpern, Benjamin S; Breed, Greg A; Nickel, Barry; Teutschel, Nicole M; Crowder, Larry B; Benson, Scott; Dutton, Peter H; Bailey, Helen; Kappes, Michelle A; Kuhn, Carey E; Weise, Michael J; Mate, Bruce; Shaffer, Scott A; Hassrick, Jason L; Henry, Robert W; Irvine, Ladd; McDonald, Birgitte I; Robinson, Patrick W; Block, Barbara A; Costa, Daniel P

    2013-01-01

    Stressors associated with human activities interact in complex ways to affect marine ecosystems, yet we lack spatially explicit assessments of cumulative impacts on ecologically and economically key components such as marine predators. Here we develop a metric of cumulative utilization and impact (CUI) on marine predators by combining electronic tracking data of eight protected predator species (n=685 individuals) in the California Current Ecosystem with data on 24 anthropogenic stressors. We show significant variation in CUI with some of the highest impacts within US National Marine Sanctuaries. High variation in underlying species and cumulative impact distributions means that neither alone is sufficient for effective spatial management. Instead, comprehensive management approaches accounting for both cumulative human impacts and trade-offs among multiple stressors must be applied in planning the use of marine resources.

  11. Cumulative cultural learning: Development and diversity.

    Science.gov (United States)

    Legare, Cristine H

    2017-07-24

    The complexity and variability of human culture is unmatched by any other species. Humans live in culturally constructed niches filled with artifacts, skills, beliefs, and practices that have been inherited, accumulated, and modified over generations. A causal account of the complexity of human culture must explain its distinguishing characteristics: It is cumulative and highly variable within and across populations. I propose that the psychological adaptations supporting cumulative cultural transmission are universal but are sufficiently flexible to support the acquisition of highly variable behavioral repertoires. This paper describes variation in the transmission practices (teaching) and acquisition strategies (imitation) that support cumulative cultural learning in childhood. Examining flexibility and variation in caregiver socialization and children's learning extends our understanding of evolution in living systems by providing insight into the psychological foundations of cumulative cultural transmission-the cornerstone of human cultural diversity.

  12. Next generation of adeno-associated virus 2 vectors: Point mutations in tyrosines lead to high-efficiency transduction at lower doses

    OpenAIRE

    Zhong, Li; Li, Baozheng; Mah, Cathryn S.; Govindasamy, Lakshmanan; Agbandje-McKenna, Mavis; Cooper, Mario; Herzog, Roland W.; Zolotukhin, Irene; Warrington, Kenneth H.; Weigel-Van Aken, Kirsten A.; Hobbs, Jacqueline A.; Zolotukhin, Sergei; Muzyczka, Nicholas; Srivastava, Arun

    2008-01-01

    Recombinant adeno-associated virus 2 (AAV2) vectors are in use in several Phase I/II clinical trials, but relatively large vector doses are needed to achieve therapeutic benefits. Large vector doses also trigger an immune response as a significant fraction of the vectors fails to traffic efficiently to the nucleus and is targeted for degradation by the host cell proteasome machinery. We have reported that epidermal growth factor receptor protein tyrosine kinase (EGFR-PTK) signaling negatively...

  13. Pulmonary instillation of low doses of titanium dioxide nanoparticles in mice leads to particle retention and gene expression changes in the absence of inflammation

    International Nuclear Information System (INIS)

    Husain, Mainul; Saber, Anne T.; Guo, Charles; Jacobsen, Nicklas R.; Jensen, Keld A.; Yauk, Carole L.; Williams, Andrew; Vogel, Ulla; Wallin, Hakan; Halappanavar, Sabina

    2013-01-01

    We investigated gene expression, protein synthesis, and particle retention in mouse lungs following intratracheal instillation of varying doses of nano-sized titanium dioxide (nano-TiO 2 ). Female C57BL/6 mice were exposed to rutile nano-TiO 2 via single intratracheal instillations of 18, 54, and 162 μg/mouse. Mice were sampled 1, 3, and 28 days post-exposure. The deposition of nano-TiO 2 in the lungs was assessed using nanoscale hyperspectral microscopy. Biological responses in the pulmonary system were analyzed using DNA microarrays, pathway-specific real-time RT-PCR (qPCR), gene-specific qPCR arrays, and tissue protein ELISA. Hyperspectral mapping showed dose-dependent retention of nano-TiO 2 in the lungs up to 28 days post-instillation. DNA microarray analysis revealed approximately 3000 genes that were altered across all treatment groups (± 1.3 fold; p 2 in the absence of inflammation over time may potentially perturb calcium and ion homeostasis, and affect smooth muscle activities. - Highlights: • Pulmonary effects following exposure to low doses of nano-TiO 2 were examined. • Particle retention in lungs was assessed using nanoscale hyperspectral microscopy. • Particles persisted up to 28 days in lungs in all dose groups. • Inflammation was the pathway affected in the high dose group at all time points. • Ion homeostasis and muscle activity pathways were affected in the low dose group

  14. Calculating Cumulative Binomial-Distribution Probabilities

    Science.gov (United States)

    Scheuer, Ernest M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, CUMBIN, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), used independently of one another. Reliabilities and availabilities of k-out-of-n systems analyzed. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Used for calculations of reliability and availability. Program written in C.

  15. About the cumulants of periodic signals

    Science.gov (United States)

    Barrau, Axel; El Badaoui, Mohammed

    2018-01-01

    This note studies cumulants of time series. These functions originating from the probability theory being commonly used as features of deterministic signals, their classical properties are examined in this modified framework. We show additivity of cumulants, ensured in the case of independent random variables, requires here a different hypothesis. Practical applications are proposed, in particular an analysis of the failure of the JADE algorithm to separate some specific periodic signals.

  16. Experience of cumulative effects assessment in the UK

    Directory of Open Access Journals (Sweden)

    Piper Jake

    2004-01-01

    Full Text Available Cumulative effects assessment (CEA is a development of environmental impact assessment which attempts to take into account the wider picture of what impacts may affect the environment as a result of either multiple or linear projects, or development plans. CEA is seen as a further valuable tool in promoting sustainable development. The broader canvas upon which the assessment is made leads to a suite of issues such as complexity in methods and assessment of significance, the desirability of co-operation between developers and other parties, new ways of addressing mitigation and monitoring. After outlining the legislative position and the process of CEA, this paper looks at three cases studies in the UK where cumulative assessment has been carried out - the cases concern wind farms, major infrastructure and off-shore developments.

  17. Cumulative effects assessment: Does scale matter?

    International Nuclear Information System (INIS)

    Therivel, Riki; Ross, Bill

    2007-01-01

    Cumulative effects assessment (CEA) is (or should be) an integral part of environmental assessment at both the project and the more strategic level. CEA helps to link the different scales of environmental assessment in that it focuses on how a given receptor is affected by the totality of plans, projects and activities, rather than on the effects of a particular plan or project. This article reviews how CEAs consider, and could consider, scale issues: spatial extent, level of detail, and temporal issues. It is based on an analysis of Canadian project-level CEAs and UK strategic-level CEAs. Based on a review of literature and, especially, case studies with which the authors are familiar, it concludes that scale issues are poorly considered at both levels, with particular problems being unclear or non-existing cumulative effects scoping methodologies; poor consideration of past or likely future human activities beyond the plan or project in question; attempts to apportion 'blame' for cumulative effects; and, at the plan level, limited management of cumulative effects caused particularly by the absence of consent regimes. Scale issues are important in most of these problems. However both strategic-level and project-level CEA have much potential for managing cumulative effects through better siting and phasing of development, demand reduction and other behavioural changes, and particularly through setting development consent rules for projects. The lack of strategic resource-based thresholds constrains the robust management of strategic-level cumulative effects

  18. Pulmonary instillation of low doses of titanium dioxide nanoparticles in mice leads to particle retention and gene expression changes in the absence of inflammation

    Energy Technology Data Exchange (ETDEWEB)

    Husain, Mainul, E-mail: mainul.husain@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Health Canada, Ottawa, Ontario K1A 0K9 (Canada); Saber, Anne T., E-mail: ats@nrcwe.dk [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Guo, Charles, E-mail: charles.guo@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Health Canada, Ottawa, Ontario K1A 0K9 (Canada); Jacobsen, Nicklas R., E-mail: nrj@nrcwe.dk [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Jensen, Keld A., E-mail: kaj@nrcwe.dk [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Yauk, Carole L., E-mail: carole.yauk@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Health Canada, Ottawa, Ontario K1A 0K9 (Canada); Williams, Andrew, E-mail: andrew.williams@hc-sc.gc.ca [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Vogel, Ulla, E-mail: ubv@nrcwe.dk [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Department of Micro- and Nanotechnology, Technical University of Denmark, Kgs. Lyngby DK-2800 (Denmark); Wallin, Hakan, E-mail: hwa@nrcwe.dk [The Danish NanoSafety Centre, National Research Centre for the Working Environment, Copenhagen DK-2100 (Denmark); Institute of Public Health, University of Copenhagen, Copenhagen DK-1014 (Denmark); Halappanavar, Sabina, E-mail: sabina.halappanavar@hc-sc.gc.ca [Environmental Health Science and Research Bureau, Health Canada, Ottawa, Ontario K1A 0K9 (Canada)

    2013-06-15

    We investigated gene expression, protein synthesis, and particle retention in mouse lungs following intratracheal instillation of varying doses of nano-sized titanium dioxide (nano-TiO{sub 2}). Female C57BL/6 mice were exposed to rutile nano-TiO{sub 2} via single intratracheal instillations of 18, 54, and 162 μg/mouse. Mice were sampled 1, 3, and 28 days post-exposure. The deposition of nano-TiO{sub 2} in the lungs was assessed using nanoscale hyperspectral microscopy. Biological responses in the pulmonary system were analyzed using DNA microarrays, pathway-specific real-time RT-PCR (qPCR), gene-specific qPCR arrays, and tissue protein ELISA. Hyperspectral mapping showed dose-dependent retention of nano-TiO{sub 2} in the lungs up to 28 days post-instillation. DNA microarray analysis revealed approximately 3000 genes that were altered across all treatment groups (± 1.3 fold; p < 0.1). Several inflammatory mediators changed in a dose- and time-dependent manner at both the mRNA and protein level. Although no influx of neutrophils was detected at the low dose, changes in the expression of several genes and proteins associated with inflammation were observed. Resolving inflammation at the medium dose, and lack of neutrophil influx in the lung fluid at the low dose, were associated with down-regulation of genes involved in ion homeostasis and muscle regulation. Our gene expression results imply that retention of nano-TiO{sub 2} in the absence of inflammation over time may potentially perturb calcium and ion homeostasis, and affect smooth muscle activities. - Highlights: • Pulmonary effects following exposure to low doses of nano-TiO{sub 2} were examined. • Particle retention in lungs was assessed using nanoscale hyperspectral microscopy. • Particles persisted up to 28 days in lungs in all dose groups. • Inflammation was the pathway affected in the high dose group at all time points. • Ion homeostasis and muscle activity pathways were affected in the low dose

  19. Low-dose-rate radiation exposure leads to testicular damage with decreases in DNMT1 and HDAC1 in the murine testis

    International Nuclear Information System (INIS)

    Gong, Eun Ji; Son, Tae Gen; Yang, Kwangmo; Heo, Kyu; Kim, Joong Sun; Shin, In Sik

    2014-01-01

    This study examined the effects of continuous low-dose-rate radiation exposure (3.49 mGy/h) of gamma rays on mice testicles. C57BL/6 mice were divided into sham and radiation groups (n = 8 each), and were exposed to either sham irradiation or 2 Gy for 21 days, 0.2 Gy for 2 days, or 0.02 Gy for 6 h of low-dose-rate irradiation. Testicular weight, seminiferous tubular diameter, and seminiferous epithelial depth were significantly decreased in the mice irradiated with 2 Gy at 1 and 9 days after exposure. Moreover, the low-dose-rate radiation exposure induced an increase in malondialdehyde levels, and a decrease in superoxide dismutase activity in the testis of mice irradiated with 2 Gy at 1 and 9 days after exposure. The sperm count and motility in the epididymis also decreased in mice irradiated with 2 Gy at 1 and 9 days after exposure, whereas there was no significant effect on the proportion of abnormal sperm. The expressions of DNA methlytransferases-1 and histone deacetylases 1 in testes irradiated with 2 Gy were significantly decreased compared with the sham group. In conclusion, the damage exerted on the testes and epididymis largely depended on the total dose of low-dose-rate radiation. (author)

  20. Polonium-210 and lead-210 in food and tobacco products: a review of parameters and an estimate of potential exposure and dose

    Energy Technology Data Exchange (ETDEWEB)

    Watson, A.P.

    1983-07-01

    Food-chain transport of Pb-210 and Po-210 from soil to edible plant parts and from animal feed to meat and milk were evaluated from a review of literature. The degree of transfer was characterized by estimating concentration factors (unweighted arithmetic means) as well as the transfer coefficients B/sub v/, B/sub r/ (unweighted geometric means, f/sub m/ and f/sub f/ (unweighted arithmetic means). Global dietary intake of Pb-210 and Po-210 was also summarized, and 50-year dose estimates to target organs calculated. The greatest estimated ingestion doses were those to populations with large dietary complements of animal protein in the form of seafood (Japan) or caribou/reindeer muscle and organ meats (Arctic Eskimos and Lapps). The magnitude of this latter source illustrates the importance of simple food chains in generating significant exposures to populations dependent upon them. The origin and magnitude of inhalation exposure and dose from tobacco products was also assessed. For the majority of internal organs evaluated, the dose resulting from smoking commercially available tobacco products is comparable to or greater than the dose estimates for ingestion of naturally occurring dietary Pb-210 and Po-210.

  1. Polonium-210 and lead-210 in food and tobacco products: a review of parameters and an estimate of potential exposure and dose

    International Nuclear Information System (INIS)

    Watson, A.P.

    1983-07-01

    Food-chain transport of Pb-210 and Po-210 from soil to edible plant parts and from animal feed to meat and milk were evaluated from a review of literature. The degree of transfer was characterized by estimating concentration factors (unweighted arithmetic means) as well as the transfer coefficients B/sub v/, B/sub r/ (unweighted geometric means, f/sub m/ and f/sub f/ (unweighted arithmetic means). Global dietary intake of Pb-210 and Po-210 was also summarized, and 50-year dose estimates to target organs calculated. The greatest estimated ingestion doses were those to populations with large dietary complements of animal protein in the form of seafood (Japan) or caribou/reindeer muscle and organ meats (Arctic Eskimos and Lapps). The magnitude of this latter source illustrates the importance of simple food chains in generating significant exposures to populations dependent upon them. The origin and magnitude of inhalation exposure and dose from tobacco products was also assessed. For the majority of internal organs evaluated, the dose resulting from smoking commercially available tobacco products is comparable to or greater than the dose estimates for ingestion of naturally occurring dietary Pb-210 and Po-210

  2. Acute and Cumulative Effects of Unmodified 50-nm Nano-ZnO on Mice.

    Science.gov (United States)

    Kong, Tao; Zhang, Shu-Hui; Zhang, Ji-Liang; Hao, Xue-Qin; Yang, Fan; Zhang, Cai; Yang, Zi-Jun; Zhang, Meng-Yu; Wang, Jie

    2018-01-02

    Nanometer zinc oxide (nano-ZnO) is widely used in diverse industrial and agricultural fields. Due to the extensive contact humans have with these particles, it is crucial to understand the potential effects that nano-ZnO have on human health. Currently, information related to the toxicity and mechanisms of nano-ZnO is limited. The aim of the present study was to investigate acute and cumulative toxic effects of 50-nm unmodified ZnO in mice. This investigation will seek to establish median lethal dose (LD50), a cumulative coefficient, and target organs. The acute and cumulative toxicity was investigated by Karber's method and via a dose-increasing method, respectively. During the experiment, clinical signs, mortality, body weights, hematology, serum biochemistry, gross pathology, organ weight, and histopathology were examined. The LD50 was 5177-mg/kg·bw; the 95% confidence limits for the LD50 were 5116-5238-mg/kg·bw. It could be concluded that the liver, kidney, lung, and gastrointestinal tract were target organs for the 50-nm nano-ZnO acute oral treatment. The cumulative coefficient (K) was 1.9 which indicated that the cumulative toxicity was apparent. The results also indicated that the liver, kidney, lung, and pancrea were target organs for 50-nm nano-ZnO cumulative oral exposure and might be target organs for subchronic and chronic toxicity of oral administered 50-nm ZnO.

  3. Bone cancer from radium: canine dose response explains data for mice and humans

    International Nuclear Information System (INIS)

    Raabe, O.G.; Book, S.A.; Parks, N.J.

    1980-01-01

    Analysis of lifetime studies of 243 beagles with skeletal burdens of radium-226 shows that the distribution of bone cancers clusters about a linear function of the logarithms of radiation dose rate to the skeleton and time from exposure until death. Similar relations displaced by species-dependent response ratios also provide satisfactory descriptions of the reported data on deaths from primary bone cancers in people and mice exposed to radium-226. The median cumulative doses (or times) leading to death from bone tumors are 2.9 times larger for dogs than for mice and 3.6 times larger for people than for dogs. These response ratios are well correlated with the normal life expectancies. The cumulative radiation dose required to give significant risk of bone cancer is found to be much less at lower dose rates than at higher rates, but the time required for the tumors to be manifested is longer. At low dose rates, this time exceeds the normal life-span and appears as a practical threshold, which for bone cancer is estimated to occur at an average cumulative radiation dose to the skeleton of about 50 to 110 rads for the three species

  4. Predicting Cumulative Incidence Probability: Marginal and Cause-Specific Modelling

    DEFF Research Database (Denmark)

    Scheike, Thomas H.; Zhang, Mei-Jie

    2005-01-01

    cumulative incidence probability; cause-specific hazards; subdistribution hazard; binomial modelling......cumulative incidence probability; cause-specific hazards; subdistribution hazard; binomial modelling...

  5. Predicting Cumulative Incidence Probability by Direct Binomial Regression

    DEFF Research Database (Denmark)

    Scheike, Thomas H.; Zhang, Mei-Jie

    Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard......Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard...

  6. Managing cumulative impacts: A key to sustainability?

    Energy Technology Data Exchange (ETDEWEB)

    Hunsaker, C.T.

    1994-12-31

    This paper addresses how science can be more effectively used in creating policy to manage cumulative effects on ecosystems. The paper focuses on the scientific techniques that we have to identify and to assess cumulative impacts on ecosystems. The term ``sustainable development`` was brought into common use by the World Commission on Environment and Development (The Brundtland Commission) in 1987. The Brundtland Commission report highlighted the need to simultaneously address developmental and environmental imperatives simultaneously by calling for development that ``meets the needs of the present generation without compromising the needs of future generations.`` We cannot claim to be working toward sustainable development until we can quantitatively assess cumulative impacts on the environment: The two concepts are inextricibally linked in that the elusiveness of cumulative effects likely has the greatest potential of keeping us from achieving sustainability. In this paper, assessment and management frameworks relevant to cumulative impacts are discussed along with recent literature on how to improve such assessments. When possible, examples are given for marine ecosystems.

  7. The injury and cumulative effects on human skin by UV exposure from artificial fluorescence emission.

    Science.gov (United States)

    Tian, Yan; Liu, Wei; Niu, TianHui; Dai, CaiHong; Li, Xiaoxin; Cui, Caijuan; Zhao, Xinyan; E, Yaping; Lu, Hui

    2014-01-01

    The injury and cumulative effects of UV emission from fluorescence lamp were studied. UV intensity from fluorescence lamp was measured, and human skin samples (hips, 10 volunteers) were exposed to low-dose UV irradiation (three times per week for 13 consecutive weeks). Three groups were examined: control group without UV radiation; low-dose group with a cumulative dose of 50 J cm(-2) which was equivalent to irradiation of the face during indoor work for 1.5 years; and high-dose group with 1000 J cm(-2) cumulative dose equivalent to irradiation of the face during outdoor activities for 1 year. Specific indicators were measured before and after UVA irradiation. The findings showed that extending the low-dose UVA exposure decreased the skin moisture content and increased the transepidermal water loss as well as induced skin color changes (decreased L* value, increased M index). Furthermore, irradiated skin showed an increased thickness of cuticle and epidermis, skin edema, light color and unclear staining collagen fibers in the dermis, and elastic fiber fragmentation. In addition, MMP-1, p53 and SIRT1 expression was also increased. Long-term exposure of low-dose UVA radiation enhanced skin photoaging. The safety of the fluorescent lamp needs our attention. © 2014 The American Society of Photobiology.

  8. Anemia risk in relation to lead exposure in lead-related manufacturing

    Directory of Open Access Journals (Sweden)

    Nan-Hung Hsieh

    2017-05-01

    Full Text Available Abstract Background Lead-exposed workers may suffer adverse health effects under the currently regulated blood lead (BPb levels. However, a probabilistic assessment about lead exposure-associated anemia risk is lacking. The goal of this study was to examine the association between lead exposure and anemia risk among factory workers in Taiwan. Methods We first collated BPb and indicators of hematopoietic function data via health examination records that included 533 male and 218 female lead-exposed workers between 2012 and 2014. We used benchmark dose (BMD modeling to estimate the critical effect doses for detection of abnormal indicators. A risk-based probabilistic model was used to characterize the potential hazard of lead poisoning for job-specific workers by hazard index (HI. We applied Bayesian decision analysis to determine whether BMD could be implicated as a suitable BPb standard. Results Our results indicated that HI for total lead-exposed workers was 0.78 (95% confidence interval: 0.50–1.26 with risk occurrence probability of 11.1%. The abnormal risk of anemia indicators for male and female workers could be reduced, respectively, by 67–77% and 86–95% by adopting the suggested BPb standards of 25 and 15 μg/dL. Conclusions We conclude that cumulative exposure to lead in the workplace was significantly associated with anemia risk. This study suggests that current BPb standard needs to be better understood for the application of lead-exposed population protection in different scenarios to provide a novel standard for health management. Low-level lead exposure risk is an occupational and public health problem that should be paid more attention.

  9. Perspectives on cumulative risks and impacts.

    Science.gov (United States)

    Faust, John B

    2010-01-01

    Cumulative risks and impacts have taken on different meanings in different regulatory and programmatic contexts at federal and state government levels. Traditional risk assessment methodologies, with considerable limitations, can provide a framework for the evaluation of cumulative risks from chemicals. Under an environmental justice program in California, cumulative impacts are defined to include exposures, public health effects, or environmental effects in a geographic area from the emission or discharge of environmental pollution from all sources, through all media. Furthermore, the evaluation of these effects should take into account sensitive populations and socioeconomic factors where possible and to the extent data are available. Key aspects to this potential approach include the consideration of exposures (versus risk), socioeconomic factors, the geographic or community-level assessment scale, and the inclusion of not only health effects but also environmental effects as contributors to impact. Assessments of this type extend the boundaries of the types of information that toxicologists generally provide for risk management decisions.

  10. Cumulative processes and quark distribution in nuclei

    International Nuclear Information System (INIS)

    Kondratyuk, L.; Shmatikov, M.

    1984-01-01

    Assuming existence of multiquark (mainly 12q) bags in nuclei the spectra of cumulative nucleons and mesons produced in high-energy particle-nucleus collisions are discussed. The exponential form of quark momentum distribution in 12q-bag (agreeing well with the experimental data on lepton-nucleus interactions at large q 2 ) is shown to result in quasi-exponential distribution of cumulative particles over the light-cone variable αsub(B). The dependence of f(αsub(B); psub(perpendicular)) (where psub(perpendicular) is the transverse momentum of the bag) upon psub(perpendicular) is considered. The yields of cumulative resonances as well as effects related to the u- and d-quark distributions in N > Z nuclei being different are dicscussed

  11. Cumulative Culture and Future Thinking: Is Mental Time Travel a Prerequisite to Cumulative Cultural Evolution?

    Science.gov (United States)

    Vale, G. L.; Flynn, E. G.; Kendal, R. L.

    2012-01-01

    Cumulative culture denotes the, arguably, human capacity to build on the cultural behaviors of one's predecessors, allowing increases in cultural complexity to occur such that many of our cultural artifacts, products and technologies have progressed beyond what a single individual could invent alone. This process of cumulative cultural evolution…

  12. A mixture of Iprodione and Vinclozolin delays the onset of puberty in the male rat in a cumulative manner.

    Science.gov (United States)

    Vinclozolin and iprodione are dicarboximide fungicides that display anti-androgenic effects in the male rat, which suggests co-exposure to these fungicides would lead to cumulative effects on androgen-sensitive endpoints. In order to test for cumulative effects by iprodione and v...

  13. EXAFS cumulants of CdSe

    International Nuclear Information System (INIS)

    Diop, D.

    1997-04-01

    EXAFS functions had been extracted from measurements on the K edge of Se at different temperatures between 20 and 300 K. The analysis of the EXAFS of the filtered first two shells has been done in the wavevector range laying between 2 and 15.5 A -1 in terms of the cumulants of the effective distribution of distances. The cumulants C 3 and C 4 obtained from the phase difference and the amplitude ratio methods have shown the anharmonicity in the vibrations of atoms around their equilibrium position. (author). 13 refs, 3 figs

  14. Cumulative effects of wind turbines. A guide to assessing the cumulative effects of wind energy development

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This guidance provides advice on how to assess the cumulative effects of wind energy developments in an area and is aimed at developers, planners, and stakeholders interested in the development of wind energy in the UK. The principles of cumulative assessment, wind energy development in the UK, cumulative assessment of wind energy development, and best practice conclusions are discussed. The identification and assessment of the cumulative effects is examined in terms of global environmental sustainability, local environmental quality and socio-economic activity. Supplementary guidance for assessing the principle cumulative effects on the landscape, on birds, and on the visual effect is provided. The consensus building approach behind the preparation of this guidance is outlined in the annexes of the report.

  15. Low dose multi-detector CT of the chest (iLEAD Study): Visual ranking of different simulated mAs levels

    International Nuclear Information System (INIS)

    Ley-Zaporozhan, Julia; Ley, Sebastian; Krummenauer, Frank; Ohno, Yoshiharu; Hatabu, Hiroto; Kauczor, Hans-Ulrich

    2010-01-01

    Purpose: Detailed evaluation of the lung parenchyma might be impaired by use of low dose CT as image noise increases and subsequently image quality decreases. The aim of our study was to determine the accuracy of visual perception of differences in image quality and noise at low dose chest CT. Materials and methods: Forty-four patients suffering from emphysema underwent CT (Aquilion-16, 120 kV, 150 mAs, 1 mm-collimation). Original raw data were used for simulation of 10 different mAs settings from 10 mAs to 100 mAs in 10 mAs increments. Three representative hard copy images (carina, 4 cm above, 5 cm below) were printed for evaluation of lung parenchyma (high-resolution kernel, lung window) and mediastinum (soft-kernel, soft tissue window). Ranking of expected low mAs level was performed for lung and soft tissue separately based on visual perception by three-blinded chest radiologist independently. Results were compared to the real simulated mAs. Results: The accuracy for correct ranking of the original 150 mAs scan was 89% for lung and 86% for soft tissue while it was 99% for the simulated 10 mAs for both windows. In comparison to the lowest mAs a significant error increase was found for the lung at 60-100 mAs (with error increase of 30-47%) for reader-I; 60-100 mAs for (33-64%) for reader-II and 70-100 mAs (38-57%) for reader-III. For the soft tissue: 60-150 mAs (with error increase of 28-63%) for reader-I; 50-100 mAs (35-56%) for reader-II and 50-90 mAs (35-40%) for reader-III. Conclusion: Simulated dose levels below 60 mAs (=42 mAs eff ) were clearly differentiated from higher dose levels by all readers. Therefore, imaging doses could be lowered down to 60 mAs without a diagnostically relevant increase in noise impairing image quality.

  16. High cumulative insulin exposure: a risk factor of atherosclerosis in type 1 diabetes?

    NARCIS (Netherlands)

    Muis, Marian J.; Bots, Michiel L.; Bilo, Henk J. G.; Hoogma, Roel P. L. M.; Hoekstra, Joost B. L.; Grobbee, Diederick E.; Stolk, Ronald P.

    2005-01-01

    Background: Since insulin therapy might have an atherogenic effect, we studied the relationship between cumulative insulin dose and atherosclerosis in type 1 diabetes. We have focused on patients with type 1 diabetes instead of type 2 diabetes to minimise the effect of insulin resistance as a

  17. High cumulative insulin exposure : a risk factor of atherosclerosis in type 1 diabetes?

    NARCIS (Netherlands)

    Muis, MJ; Bots, ML; Bilo, HJG; Hoogma, RPLM; Hoekstra, JBL; Grobbee, DE; Stolk, RP

    Background: Since insulin therapy might have an atherogenic effect, we studied the relationship between cumulative insulin dose and atherosclerosis in type 1 diabetes. We have focused on patients with type 1 diabetes instead of type 2 diabetes to minimise the effect of insulin resistance as a

  18. Multiparty correlation measure based on the cumulant

    International Nuclear Information System (INIS)

    Zhou, D. L.; Zeng, B.; Xu, Z.; You, L.

    2006-01-01

    We propose a genuine multiparty correlation measure for a multiparty quantum system as the trace norm of the cumulant of the state. The legitimacy of our multiparty correlation measure is explicitly demonstrated by proving it satisfies the five basic conditions required for a correlation measure. As an application we construct an efficient algorithm for the calculation of our measures for all stabilizer states

  19. Decision analysis with cumulative prospect theory.

    Science.gov (United States)

    Bayoumi, A M; Redelmeier, D A

    2000-01-01

    Individuals sometimes express preferences that do not follow expected utility theory. Cumulative prospect theory adjusts for some phenomena by using decision weights rather than probabilities when analyzing a decision tree. The authors examined how probability transformations from cumulative prospect theory might alter a decision analysis of a prophylactic therapy in AIDS, eliciting utilities from patients with HIV infection (n = 75) and calculating expected outcomes using an established Markov model. They next focused on transformations of three sets of probabilities: 1) the probabilities used in calculating standard-gamble utility scores; 2) the probabilities of being in discrete Markov states; 3) the probabilities of transitioning between Markov states. The same prophylaxis strategy yielded the highest quality-adjusted survival under all transformations. For the average patient, prophylaxis appeared relatively less advantageous when standard-gamble utilities were transformed. Prophylaxis appeared relatively more advantageous when state probabilities were transformed and relatively less advantageous when transition probabilities were transformed. Transforming standard-gamble and transition probabilities simultaneously decreased the gain from prophylaxis by almost half. Sensitivity analysis indicated that even near-linear probability weighting transformations could substantially alter quality-adjusted survival estimates. The magnitude of benefit estimated in a decision-analytic model can change significantly after using cumulative prospect theory. Incorporating cumulative prospect theory into decision analysis can provide a form of sensitivity analysis and may help describe when people deviate from expected utility theory.

  20. Cumulative watershed effects: a research perspective

    Science.gov (United States)

    Leslie M. Reid; Robert R. Ziemer

    1989-01-01

    A cumulative watershed effect (CWE) is any response to multiple land-use activities that is caused by, or results in, altered watershed function. The CWE issue is politically defined, as is the significance of particular impacts. But the processes generating CWEs are the traditional focus of geomorphology and ecology, and have thus been studied for decades. The CWE...

  1. Pulmonary instillation of low doses of titanium dioxide nanoparticles in mice leads to particle retention and gene expression changes in the absence of inflammation

    DEFF Research Database (Denmark)

    Husain, Mainul; Saber, Anne Thoustrup; Guo, Charles

    2013-01-01

    We investigated gene expression, protein synthesis, and particle retention in mouse lungs following intratracheal instillation of varying doses of nano-sized titanium dioxide (nano-TiO2). Female C57BL/6 mice were exposed to rutile nano-TiO2 via single intratracheal instillations of 18, 54, and 162......μg/mouse. Mice were sampled 1, 3, and 28days post-exposure. The deposition of nano-TiO2 in the lungs was assessed using nanoscale hyperspectral microscopy. Biological responses in the pulmonary system were analyzed using DNA microarrays, pathway-specific real-time RT-PCR (qPCR), gene-specific q...

  2. An evaluation paradigm for cumulative impact analysis

    Science.gov (United States)

    Stakhiv, Eugene Z.

    1988-09-01

    Cumulative impact analysis is examined from a conceptual decision-making perspective, focusing on its implicit and explicit purposes as suggested within the policy and procedures for environmental impact analysis of the National Environmental Policy Act of 1969 (NEPA) and its implementing regulations. In this article it is also linked to different evaluation and decision-making conventions, contrasting a regulatory context with a comprehensive planning framework. The specific problems that make the application of cumulative impact analysis a virtually intractable evaluation requirement are discussed in connection with the federal regulation of wetlands uses. The relatively familiar US Army Corps of Engineers' (the Corps) permit program, in conjunction with the Environmental Protection Agency's (EPA) responsibilities in managing its share of the Section 404 regulatory program requirements, is used throughout as the realistic context for highlighting certain pragmatic evaluation aspects of cumulative impact assessment. To understand the purposes of cumulative impact analysis (CIA), a key distinction must be made between the implied comprehensive and multiobjective evaluation purposes of CIA, promoted through the principles and policies contained in NEPA, and the more commonly conducted and limited assessment of cumulative effects (ACE), which focuses largely on the ecological effects of human actions. Based on current evaluation practices within the Corps' and EPA's permit programs, it is shown that the commonly used screening approach to regulating wetlands uses is not compatible with the purposes of CIA, nor is the environmental impact statement (EIS) an appropriate vehicle for evaluating the variety of objectives and trade-offs needed as part of CIA. A heuristic model that incorporates the basic elements of CIA is developed, including the idea of trade-offs among social, economic, and environmental protection goals carried out within the context of environmental

  3. Cumulative receipt of an anti-poverty tax credit for families did not impact tobacco smoking among parents.

    Science.gov (United States)

    Pega, Frank; Gilsanz, Paola; Kawachi, Ichiro; Wilson, Nick; Blakely, Tony

    2017-04-01

    The effect of anti-poverty tax credit interventions on tobacco consumption is unclear. Previous studies have estimated short-term effects, did not isolate the effects of cumulative dose of tax credits, produced conflicting results, and used methods with limited control for some time-varying confounders (e.g., those affected by prior treatment) and treatment regimen (i.e., study participants' tax credit receipt pattern over time). We estimated the longer-term, cumulative effect of New Zealand's Family Tax Credit (FTC) on tobacco consumption, using a natural experiment (administrative errors leading to exogenous variation in FTC receipt) and methods specifically for controlling confounding, reverse causation, and treatment regimen. We extracted seven waves (2002-2009) of the nationally representative Survey of Family, Income and Employment including 4404 working-age (18-65 years) parents in families. The exposure was the total numbers of years of receiving FTC. The outcomes were regular smoking and the average daily number of cigarettes usually smoked at wave 7. We estimated average treatment effects using inverse probability of treatment weighting and marginal structural modelling. Each additional year of receiving FTC affected neither the odds of regular tobacco smoking among all parents (odds ratio 1.02, 95% confidence interval 0.94-1.11), nor the number of cigarettes smoked among parents who smoked regularly (rate ratio 1.01, 95% confidence interval 0.99-1.03). We found no evidence for an association between the cumulative number of years of receiving an anti-poverty tax credit and tobacco smoking or consumption among parents. The assumptions of marginal structural modelling are quite demanding, and we therefore cannot rule out residual confounding. Nonetheless, our results suggest that tax credit programme participation will not increase tobacco consumption among poor parents, at least in this high-income country. Copyright © 2017 Elsevier Ltd. All rights

  4. Cumulative keyboard strokes: a possible risk factor for carpal tunnel syndrome

    Directory of Open Access Journals (Sweden)

    Eleftheriou Andreas

    2012-08-01

    Full Text Available Abstract Background Contradictory reports have been published regarding the association of Carpal Tunnel Syndrome (CTS and the use of computer keyboard. Previous studies did not take into account the cumulative exposure to keyboard strokes among computer workers. The aim of the present study was to investigate the association between cumulative keyboard use (keyboard strokes and CTS. Methods Employees (461 from a Governmental data entry & processing unit agreed to participate (response rate: 84.1 % in a cross-sectional study. Α questionnaire was distributed to the participants to obtain information on socio-demographics and risk factors for CTS. The participants were examined for signs and symptoms related to CTS and were asked if they had previous history or surgery for CTS. The cumulative amount of the keyboard strokes per worker per year was calculated by the use of payroll’s registry. Two case definitions for CTS were used. The first included subjects with personal history/surgery for CTS while the second included subjects that belonged to the first case definition plus those participants were identified through clinical examination. Results Multivariate analysis used for both case definitions, indicated that those employees with high cumulative exposure to keyboard strokes were at increased risk of CTS (case definition A: OR = 2.23;95 % CI = 1.09-4.52 and case definition B: OR = 2.41; 95%CI = 1.36-4.25. A dose response pattern between cumulative exposure to keyboard strokes and CTS has been revealed (p  Conclusions The present study indicated a possible association between cumulative exposure to keyboard strokes and development of CTS. Cumulative exposure to key-board strokes would be taken into account as an exposure indicator regarding exposure assessment of computer workers. Further research is needed in order to test the results of the current study and assess causality between cumulative keyboard strokes and

  5. Personalized Feedback on Staff Dose in Fluoroscopy-Guided Interventions: A New Era in Radiation Dose Monitoring.

    Science.gov (United States)

    Sailer, Anna M; Vergoossen, Laura; Paulis, Leonie; van Zwam, Willem H; Das, Marco; Wildberger, Joachim E; Jeukens, Cécile R L P N

    2017-11-01

    Radiation safety and protection are a key component of fluoroscopy-guided interventions. We hypothesize that providing weekly personal dose feedback will increase radiation awareness and ultimately will lead to optimized behavior. Therefore, we designed and implemented a personalized feedback of procedure and personal doses for medical staff involved in fluoroscopy-guided interventions. Medical staff (physicians and technicians, n = 27) involved in fluoroscopy-guided interventions were equipped with electronic personal dose meters (PDMs). Procedure dose data including the dose area product and effective doses from PDMs were prospectively monitored for each consecutive procedure over an 8-month period (n = 1082). A personalized feedback form was designed displaying for each staff individually the personal dose per procedure, as well as relative and cumulative doses. This study consisted of two phases: (1) 1-5th months: Staff did not receive feedback (n = 701) and (2) 6-8th months: Staff received weekly individual dose feedback (n = 381). An anonymous evaluation was performed on the feedback and occupational dose. Personalized feedback was scored valuable by 76% of the staff and increased radiation dose awareness for 71%. 57 and 52% reported an increased feeling of occupational safety and changing their behavior because of personalized feedback, respectively. For technicians, the normalized dose was significantly lower in the feedback phase compared to the prefeedback phase: [median (IQR) normalized dose (phase 1) 0.12 (0.04-0.50) µSv/Gy cm 2 versus (phase 2) 0.08 (0.02-0.24) µSv/Gy cm 2 , p = 0.002]. Personalized dose feedback increases radiation awareness and safety and can be provided to staff involved in fluoroscopy-guided interventions.

  6. Ratcheting up the ratchet: on the evolution of cumulative culture.

    Science.gov (United States)

    Tennie, Claudio; Call, Josep; Tomasello, Michael

    2009-08-27

    Some researchers have claimed that chimpanzee and human culture rest on homologous cognitive and learning mechanisms. While clearly there are some homologous mechanisms, we argue here that there are some different mechanisms at work as well. Chimpanzee cultural traditions represent behavioural biases of different populations, all within the species' existing cognitive repertoire (what we call the 'zone of latent solutions') that are generated by founder effects, individual learning and mostly product-oriented (rather than process-oriented) copying. Human culture, in contrast, has the distinctive characteristic that it accumulates modifications over time (what we call the 'ratchet effect'). This difference results from the facts that (i) human social learning is more oriented towards process than product and (ii) unique forms of human cooperation lead to active teaching, social motivations for conformity and normative sanctions against non-conformity. Together, these unique processes of social learning and cooperation lead to humans' unique form of cumulative cultural evolution.

  7. Ratcheting up the ratchet: on the evolution of cumulative culture

    Science.gov (United States)

    Tennie, Claudio; Call, Josep; Tomasello, Michael

    2009-01-01

    Some researchers have claimed that chimpanzee and human culture rest on homologous cognitive and learning mechanisms. While clearly there are some homologous mechanisms, we argue here that there are some different mechanisms at work as well. Chimpanzee cultural traditions represent behavioural biases of different populations, all within the species’ existing cognitive repertoire (what we call the ‘zone of latent solutions’) that are generated by founder effects, individual learning and mostly product-oriented (rather than process-oriented) copying. Human culture, in contrast, has the distinctive characteristic that it accumulates modifications over time (what we call the ‘ratchet effect’). This difference results from the facts that (i) human social learning is more oriented towards process than product and (ii) unique forms of human cooperation lead to active teaching, social motivations for conformity and normative sanctions against non-conformity. Together, these unique processes of social learning and cooperation lead to humans’ unique form of cumulative cultural evolution. PMID:19620111

  8. Sharing a quota on cumulative carbon emissions

    International Nuclear Information System (INIS)

    Raupach, Michael R.; Davis, Steven J.; Peters, Glen P.; Andrew, Robbie M.; Canadell, Josep G.; Ciais, Philippe

    2014-01-01

    Any limit on future global warming is associated with a quota on cumulative global CO 2 emissions. We translate this global carbon quota to regional and national scales, on a spectrum of sharing principles that extends from continuation of the present distribution of emissions to an equal per-capita distribution of cumulative emissions. A blend of these endpoints emerges as the most viable option. For a carbon quota consistent with a 2 C warming limit (relative to pre-industrial levels), the necessary long-term mitigation rates are very challenging (typically over 5% per year), both because of strong limits on future emissions from the global carbon quota and also the likely short-term persistence in emissions growth in many regions. (authors)

  9. Complexity and demographic explanations of cumulative culture.

    Science.gov (United States)

    Querbes, Adrien; Vaesen, Krist; Houkes, Wybo

    2014-01-01

    Formal models have linked prehistoric and historical instances of technological change (e.g., the Upper Paleolithic transition, cultural loss in Holocene Tasmania, scientific progress since the late nineteenth century) to demographic change. According to these models, cumulation of technological complexity is inhibited by decreasing--while favoured by increasing--population levels. Here we show that these findings are contingent on how complexity is defined: demography plays a much more limited role in sustaining cumulative culture in case formal models deploy Herbert Simon's definition of complexity rather than the particular definitions of complexity hitherto assumed. Given that currently available empirical evidence doesn't afford discriminating proper from improper definitions of complexity, our robustness analyses put into question the force of recent demographic explanations of particular episodes of cultural change.

  10. Complexity and demographic explanations of cumulative culture.

    Directory of Open Access Journals (Sweden)

    Adrien Querbes

    Full Text Available Formal models have linked prehistoric and historical instances of technological change (e.g., the Upper Paleolithic transition, cultural loss in Holocene Tasmania, scientific progress since the late nineteenth century to demographic change. According to these models, cumulation of technological complexity is inhibited by decreasing--while favoured by increasing--population levels. Here we show that these findings are contingent on how complexity is defined: demography plays a much more limited role in sustaining cumulative culture in case formal models deploy Herbert Simon's definition of complexity rather than the particular definitions of complexity hitherto assumed. Given that currently available empirical evidence doesn't afford discriminating proper from improper definitions of complexity, our robustness analyses put into question the force of recent demographic explanations of particular episodes of cultural change.

  11. Childhood Cumulative Risk and Later Allostatic Load

    DEFF Research Database (Denmark)

    Doan, Stacey N; Dich, Nadya; Evans, Gary W

    2014-01-01

    State, followed for 8 years (between the ages 9 and 17). Poverty- related stress was computed using the cumulative risk approach, assessing stressors across 9 domains, including environmental, psychosocial, and demographic factors. Allostatic load captured a range of physiological responses, including......Objective: The present study investigated the long-term impact of exposure to poverty-related stressors during childhood on allostatic load, an index of physiological dysregulation, and the potential mediating role of substance use. Method: Participants (n = 162) were rural children from New York...... cardiovascular, hypothalamic pituitary adrenal axis, sympathetic adrenal medullary system, and metabolic activity. Smoking and alcohol/drug use were tested as mediators of the hypothesized childhood risk-adolescent allostatic load relationship. Results: Cumulative risk exposure at age 9 predicted increases...

  12. LEADING WITH LEADING INDICATORS

    International Nuclear Information System (INIS)

    PREVETTE, S.S.

    2005-01-01

    This paper documents Fluor Hanford's use of Leading Indicators, management leadership, and statistical methodology in order to improve safe performance of work. By applying these methods, Fluor Hanford achieved a significant reduction in injury rates in 2003 and 2004, and the improvement continues today. The integration of data, leadership, and teamwork pays off with improved safety performance and credibility with the customer. The use of Statistical Process Control, Pareto Charts, and Systems Thinking and their effect on management decisions and employee involvement are discussed. Included are practical examples of choosing leading indicators. A statistically based color coded dashboard presentation system methodology is provided. These tools, management theories and methods, coupled with involved leadership and employee efforts, directly led to significant improvements in worker safety and health, and environmental protection and restoration at one of the nation's largest nuclear cleanup sites

  13. Studies on γ-ray induced structural changes in Nd{sup 3+} doped lead alumino silicate glasses by means of thermoluminescence for dosimetric applications in high dose ranges

    Energy Technology Data Exchange (ETDEWEB)

    Sundara Rao, M. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Gandhi, Y. [Department of Physics, Kakani Venkata Ratnam College, Nandigama 521 185, A.P. (India); Sanyal, Bhaskar [Food Technology Division, Bhabha Atomic Research Centre, Trombay, Mumbai 400 085 (India); Bhargavi, K. [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India); Piasecki, M. [Institute of Physics, J. Dlugosz University, Ul. Armii Krajowej 13/15, 42-201 Czestochowa (Poland); Veeraiah, N., E-mail: nvr8@rediffmail.com [Department of Physics, Acharya Nagarjuna University, Nagarjuna Nagar 522 510, Guntur, A.P. (India)

    2014-12-15

    Graphical abstract: TL glow curves of PbO–SiO{sub 2}:Nd{sup 3+} glasses mixed with different concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose 5.0 kGy. - Highlights: • TL studies of Nd{sup 3+} ions doped lead alumino silicate glasses were carried out. • Highest TL output was observed in the glasses mixed with 10 mol% of Al{sub 2}O{sub 3}. • Different mechanisms responsible for TL emission were discussed. • Near linearity of the dose response was observed in the dose range of 1.0–3.0 kGy. • These glasses may be useful as dosimeters in processing perishable food commodities. - Abstract: Thermoluminescence (TL) studies on PbO–Al{sub 2}O{sub 3}–SiO{sub 2}:Nd{sup 3+} glasses mixed with varying concentrations of Al{sub 2}O{sub 3} exposed to γ-rays of dose in the range 0–5.0 kGy were carried out. The TL emission exhibited a dosimetric peak at about 185 °C. The TL output under the glow peak increased with increasing Al{sub 2}O{sub 3} and also with the γ-ray dose. The mechanisms responsible for TL emission and enhancement of TL output with increase in the concentration of Al{sub 2}O{sub 3} were quantitatively discussed in terms of induced structural defects in the vicinity of Nd{sup 3+} ions due to interaction of γ-rays with the glass network in the scenario of varying concentration of Al{sub 2}O{sub 3}. The dose response of these glass samples exhibited linear behavior in the medium dose range viz., 1.0–3.0 kGy. Finally, it is concluded that the glass containing the highest concentration of Al{sub 2}O{sub 3} exhibits high TL output and such glasses are useful for dosimetry in the range 1.0–3.0 kGy and hence these glasses may be useful for dosimetry in such high range of doses required for commercial radiation processing of perishable food commodities to extend their shelf-lives.

  14. Fuzzy set theory for cumulative trauma prediction

    OpenAIRE

    Fonseca, Daniel J.; Merritt, Thomas W.; Moynihan, Gary P.

    2001-01-01

    A widely used fuzzy reasoning algorithm was modified and implemented via an expert system to assess the potential risk of employee repetitive strain injury in the workplace. This fuzzy relational model, known as the Priority First Cover Algorithm (PFC), was adapted to describe the relationship between 12 cumulative trauma disorders (CTDs) of the upper extremity, and 29 identified risk factors. The algorithm, which finds a suboptimal subset from a group of variables based on the criterion of...

  15. Sikap Kerja Duduk Terhadap Cumulative Trauma Disorder

    OpenAIRE

    Rahmawati, Yulita; Sugiharto, -

    2011-01-01

    Permasalahan yang diteliti adalah adakah hubungan antara sikap kerja duduk dengan kejadian Cumulative Trauma Disorder (CTD) pada pekerja bagian pengamplasan di PT. Geromar Jepara. Tujuan yang ingin dicapai adalah untuk mengetahui hubungan antara sikap kerja duduk dengan kejadian CTD pada pekerja bagian pengamplasan. Metode penelitian ini bersifat explanatory dengan menggunakan pendekatan belah lintang. Populasi dalam penelitian ini adalah pekerja bagian pengamplasan sebanyak 30 orang. Teknik ...

  16. Power Reactor Docket Information. Annual cumulation (citations)

    International Nuclear Information System (INIS)

    1977-12-01

    An annual cumulation of the citations to the documentation associated with civilian nuclear power plants is presented. This material is that which is submitted to the U.S. Nuclear Regulatory Commission in support of applications for construction and operating licenses. Citations are listed by Docket number in accession number sequence. The Table of Contents is arranged both by Docket number and by nuclear power plant name

  17. Cumulative Effect of Depression on Dementia Risk

    OpenAIRE

    Olazarán, J.; Trincado, R.; Bermejo-Pareja, F.

    2013-01-01

    Objective. To analyze a potential cumulative effect of life-time depression on dementia and Alzheimer's disease (AD), with control of vascular factors (VFs). Methods. This study was a subanalysis of the Neurological Disorders in Central Spain (NEDICES) study. Past and present depression, VFs, dementia status, and dementia due to AD were documented at study inception. Dementia status was also documented after three years. Four groups were created according to baseline data: never depression (n...

  18. Cumulative release to the accessible environment

    International Nuclear Information System (INIS)

    Kanehiro, B.

    1985-01-01

    The Containment and Isolation Working Group considered issues related to the postclosure behavior of repositories in crystalline rock. This working group was further divided into subgroups to consider the progress since the 1978 GAIN Symposium and identify research needs in the individual areas of regional ground-water flow, ground-water travel time, fractional release, and cumulative release. The analysis and findings of the Fractional Release Subgroup are presented

  19. EPA Workshop on Epigenetics and Cumulative Risk ...

    Science.gov (United States)

    Agenda Download the Workshop Agenda (PDF) The workshop included presentations and discussions by scientific experts pertaining to three topics (i.e., epigenetic changes associated with diverse stressors, key science considerations in understanding epigenetic changes, and practical application of epigenetic tools to address cumulative risks from environmental stressors), to address several questions under each topic, and included an opportunity for attendees to participate in break-out groups, provide comments and ask questions. Workshop Goals The workshop seeks to examine the opportunity for use of aggregate epigenetic change as an indicator in cumulative risk assessment for populations exposed to multiple stressors that affect epigenetic status. Epigenetic changes are specific molecular changes around DNA that alter expression of genes. Epigenetic changes include DNA methylation, formation of histone adducts, and changes in micro RNAs. Research today indicates that epigenetic changes are involved in many chronic diseases (cancer, cardiovascular disease, obesity, diabetes, mental health disorders, and asthma). Research has also linked a wide range of stressors including pollution and social factors with occurrence of epigenetic alterations. Epigenetic changes have the potential to reflect impacts of risk factors across multiple stages of life. Only recently receiving attention is the nexus between the factors of cumulative exposure to environmental

  20. Higher order cumulants in colorless partonic plasma

    Energy Technology Data Exchange (ETDEWEB)

    Cherif, S. [Sciences and Technologies Department, University of Ghardaia, Ghardaia, Algiers (Algeria); Laboratoire de Physique et de Mathématiques Appliquées (LPMA), ENS-Kouba (Bachir El-Ibrahimi), Algiers (Algeria); Ahmed, M. A. A. [Department of Physics, College of Science, Taibah University Al-Madinah Al-Mounawwarah KSA (Saudi Arabia); Department of Physics, Taiz University in Turba, Taiz (Yemen); Laboratoire de Physique et de Mathématiques Appliquées (LPMA), ENS-Kouba (Bachir El-Ibrahimi), Algiers (Algeria); Ladrem, M., E-mail: mladrem@yahoo.fr [Department of Physics, College of Science, Taibah University Al-Madinah Al-Mounawwarah KSA (Saudi Arabia); Laboratoire de Physique et de Mathématiques Appliquées (LPMA), ENS-Kouba (Bachir El-Ibrahimi), Algiers (Algeria)

    2016-06-10

    Any physical system considered to study the QCD deconfinement phase transition certainly has a finite volume, so the finite size effects are inevitably present. This renders the location of the phase transition and the determination of its order as an extremely difficult task, even in the simplest known cases. In order to identify and locate the colorless QCD deconfinement transition point in finite volume T{sub 0}(V), a new approach based on the finite-size cumulant expansion of the order parameter and the ℒ{sub m,n}-Method is used. We have shown that both cumulants of higher order and their ratios, associated to the thermodynamical fluctuations of the order parameter, in QCD deconfinement phase transition behave in a particular enough way revealing pronounced oscillations in the transition region. The sign structure and the oscillatory behavior of these in the vicinity of the deconfinement phase transition point might be a sensitive probe and may allow one to elucidate their relation to the QCD phase transition point. In the context of our model, we have shown that the finite volume transition point is always associated to the appearance of a particular point in whole higher order cumulants under consideration.

  1. Cumulative irritation potential of topical retinoid formulations.

    Science.gov (United States)

    Leyden, James J; Grossman, Rachel; Nighland, Marge

    2008-08-01

    Localized irritation can limit treatment success with topical retinoids such as tretinoin and adapalene. The factors that influence irritant reactions have been shown to include individual skin sensitivity, the particular retinoid and concentration used, and the vehicle formulation. To compare the cutaneous tolerability of tretinoin 0.04% microsphere gel (TMG) with that of adapalene 0.3% gel and a standard tretinoin 0.025% cream. The results of 2 randomized, investigator-blinded studies of 2 to 3 weeks' duration, which utilized a split-face method to compare cumulative irritation scores induced by topical retinoids in subjects with healthy skin, were combined. Study 1 compared TMG 0.04% with adapalene 0.3% gel over 2 weeks, while study 2 compared TMG 0.04% with tretinoin 0.025% cream over 3 weeks. In study 1, TMG 0.04% was associated with significantly lower cumulative scores for erythema, dryness, and burning/stinging than adapalene 0.3% gel. However, in study 2, there were no significant differences in cumulative irritation scores between TMG 0.04% and tretinoin 0.025% cream. Measurements of erythema by a chromameter showed no significant differences between the test formulations in either study. Cutaneous tolerance of TMG 0.04% on the face was superior to that of adapalene 0.3% gel and similar to that of a standard tretinoin cream containing a lower concentration of the drug (0.025%).

  2. Metronomic Treatment with Low-Dose Trofosfamide Leads to a Long-Term Remission in a Patient with Docetaxel-Refractory Advanced Metastatic Prostate Cancer

    Directory of Open Access Journals (Sweden)

    Jochen Greiner

    2010-01-01

    Full Text Available The treatment of metastatic prostate cancer patients refractory to androgen withdrawal and docetaxel therapy is currently discouraging and new therapeutic approaches are vastly needed. Here, we report a long-term remission over one year in a 68-year-old patient with metastatic docetaxel-refractory prostate cancer employing low-dose trofosfamide. The patient suffered from distant failure with several bone lesions and lymph node metastases depicted by a (11 C-Choline positron emission tomography/computerized tomography (PET/CT. After initiation of trofosfamide 100 mg taken orally once a day we observed a steadily decreasing PSA value from initial 46.6 down to 2.1 g/l. The Choline-PET/CT was repeated after 10 months of continuous therapy and demonstrated a partial remission of the bone lesions and a regression of all involved lymph nodes but one. Taken together we found an astonishing and durable activity of the alkylating agent trofosfamide given in a metronomic fashion. We rate the side effects as low and state an excellent therapeutic ratio of this drug in our patient.

  3. Study on reducing radiation dose in dental radiography for children, 1. The seltering effects of lead content rubber sheet and ready-made apron

    Energy Technology Data Exchange (ETDEWEB)

    Shikone, Mitsuru; Tsuchida, Atsushi; Tateno, Hidemi; Uchimura, Noboru; Higaki, Morio; Kanno, Masanori; Higashi, Tomomitsu

    1986-12-01

    X-ray examination is one of the effective diagnoses in dentistry. And it is difficult to conduct a precise dental examination without X-ray films, especially in pedodontics. However, radiography may be attended with many radiation injury, and we must perform the complete protection of patients when taking X-ray radiography for children, because their tissues are much more sensitive to radiation than those of adult. Children have some radiosensitive immature organs such as the thyroid gland, eyes (crystalline lens), gonad etc., accordingly, it is very important to protect them from exposure of X-rey. It has been suggested that the thyroid gland is the most sensitive to radiation among many organs. We, therefore, establish a protector for children's thyroid gland as soon as possible. In this study, the auther had designed X-ray protecting rubber sheet which had various lead contents, for finding an optimum condition of the protector. Additionally, the sheltering effects were compared among ready-made protectors. 1. It was satisfactory for complete sheltering of direct beam that the rubber sheet contained 0.375 mmPb, 0.5 mmPb, and 0.75 mmPb, at the tubevoltage of 65 kVp, 70 kVp and 80 kVp, respectively. 2. The radiolucency ratio of Hagoromo Apron containing 0.25 mmPb was 0 % at 65 kVp, and that of X-ray Shield containing 0.50 mmPb was 0 % at 65, 70 kVp and 80 kVp too. 3. Among the ready-made aprons, there was one which had less lead content than the indicated value.

  4. A Cumulant-based Analysis of Nonlinear Magnetospheric Dynamics

    International Nuclear Information System (INIS)

    Johnson, Jay R.; Wing, Simon

    2004-01-01

    Understanding magnetospheric dynamics and predicting future behavior of the magnetosphere is of great practical interest because it could potentially help to avert catastrophic loss of power and communications. In order to build good predictive models it is necessary to understand the most critical nonlinear dependencies among observed plasma and electromagnetic field variables in the coupled solar wind/magnetosphere system. In this work, we apply a cumulant-based information dynamical measure to characterize the nonlinear dynamics underlying the time evolution of the Dst and Kp geomagnetic indices, given solar wind magnetic field and plasma input. We examine the underlying dynamics of the system, the temporal statistical dependencies, the degree of nonlinearity, and the rate of information loss. We find a significant solar cycle dependence in the underlying dynamics of the system with greater nonlinearity for solar minimum. The cumulant-based approach also has the advantage that it is reliable even in the case of small data sets and therefore it is possible to avoid the assumption of stationarity, which allows for a measure of predictability even when the underlying system dynamics may change character. Evaluations of several leading Kp prediction models indicate that their performances are sub-optimal during active times. We discuss possible improvements of these models based on this nonparametric approach

  5. A bivariate optimal replacement policy with cumulative repair cost ...

    Indian Academy of Sciences (India)

    Min-Tsai Lai

    Shock model; cumulative damage model; cumulative repair cost limit; preventive maintenance model. 1. Introduction ... with two types of shocks: one type is failure shock, and the other type is damage ...... Theory, methods and applications.

  6. On interference of cumulative proton production mechanisms

    International Nuclear Information System (INIS)

    Braun, M.A.; Vechernin, V.V.

    1993-01-01

    The dynamical picture of the cumulative proton production in hA-collisions by means of diagram analysis with NN interaction described by a non-relativistic NN potential is considered. The contributions of the various mechanisms (spectator, direct and rescattering) for backward hemisphere proton production within the framework of this common approach is calculated. The emphasis is on the comparison of the relative contributions of these mechanisms for various angles, taking into account the interference of these contributions. Comparison with experimental data is also presented. (author)

  7. Preserved cumulative semantic interference despite amnesia

    Directory of Open Access Journals (Sweden)

    Gary Michael Oppenheim

    2015-05-01

    As predicted by Oppenheim et al’s (2010 implicit incremental learning account, WRP’s BCN RTs demonstrated strong (and significant repetition priming and semantic blocking effects (Figure 1. Similar to typical results from neurally intact undergraduates, WRP took longer to name pictures presented in semantically homogeneous blocks than in heterogeneous blocks, an effect that increased with each cycle. This result challenges accounts that ascribe cumulative semantic interference in this task to explicit memory mechanisms, instead suggesting that the effect has the sort of implicit learning bases that are typically spared in hippocampal amnesia.

  8. Is cumulated pyrethroid exposure associated with prediabetes?

    DEFF Research Database (Denmark)

    Hansen, Martin Rune; Jørs, Erik; Lander, Flemming

    2014-01-01

    was to investigate an association between exposure to pyrethroids and abnormal glucose regulation (prediabetes or diabetes). A cross-sectional study was performed among 116 pesticide sprayers from public vector control programs in Bolivia and 92 nonexposed controls. Pesticide exposure (duration, intensity...... pyrethroids, a significant positive trend was observed between cumulative pesticide exposure (total number of hours sprayed) and adjusted OR of abnormal glucose regulation, with OR 14.7 [0.9-235] in the third exposure quintile. The study found a severely increased prevalence of prediabetes among Bolivian...

  9. The use of steel and lead shieldings in radiotherapy rooms and its comparison with respect to neutrons doses at patients; Comparacao de blindagens de aco e de chumbo usadas em salas de radioterapia quanto a dose devido a neutrons depositada em pacientes

    Energy Technology Data Exchange (ETDEWEB)

    Silva, M.G.; Rebello, W.F.; Andrade, E.R.; Medeiros, M.P.C.; Mendes, R.M.S.; Braga, K.L.; Gomes, R.G., E-mail: maglosilva15@gmail.com, E-mail: rebello@ime.eb.br, E-mail: fisica.dna@gmail.com, E-mail: eng.cavaliere@gmail.com, E-mail: raphaelmsm@gmail.com, E-mail: kelmo.lins@gmail.com, E-mail: ggrprojetos@gmail.com [Instituto Militar de Engenharia (IME), Rio de Janeiro, RJ (Brazil); Santos, R.F.G., E-mail: raphaelfgsantos@gmail.com [Centro Universitario Anhanguera, Niteroi, RJ (Brazil). Departamento de Engenharia; Silva, Ademir X., E-mail: ademir@con.ufrj.br [Universidade Federal do Rio de Janeiro (UFRJ), Rio de Janeiro, RJ (Brazil)

    2015-07-01

    The NCRP Report No. 151, Structural Shielding Design and Evaluation for Megavoltage X- and Gamma-Ray Radiotherapy Facilities, considers, in shielding calculations for radiotherapy rooms, the use of lead and/or steel to be applied on bunker walls. The NCRP Report calculations were performed foreseeing a better protection of people outside the radiotherapy room. However, contribution of lead and steel to patient dose should be taken into account for radioprotection purposes. This work presents calculations performed by MCNPX code in analyzing the Ambient Dose Equivalent due to neutron, H*(10){sub n}, within a radiotherapy room, in the patients area, considering the use of additional shielding of 1 TVL of lead or 1 TVL of steel, positioned at the inner faces of walls and ceiling of a bunker. The head of the linear accelerator Varian 2100/2300 C/D was modeled working at 18MeV, with 5x5cm{sup 2}, 10x10cm{sup 2}, 20x20cm{sup 2}, 30x30cm{sup 2} and 40x40cm{sup 2} openings for jaws and MLC and operating in eight gantry's angles. This study shows that the use of lead generates an average value of H*(10){sub n} at patients area, 8.02% higher than the expected when using steel. Further studies should be performed based on experimental data for comparison with those from MCNPX simulation.

  10. Cumulative Advantage in the Skill Development of STEM Graduate Students: A Mixed-Methods Study

    Science.gov (United States)

    Feldon, David F.; Maher, Michelle A.; Roksa, Josipa; Peugh, James

    2016-01-01

    Studies of skill development often describe a process of cumulative advantage, in which small differences in initial skill compound over time, leading to increasing skill gaps between those with an initial advantage and those without. We offer evidence of a similar phenomenon accounting for differential patterns of research skill development in…

  11. Chapter 19. Cumulative watershed effects and watershed analysis

    Science.gov (United States)

    Leslie M. Reid

    1998-01-01

    Cumulative watershed effects are environmental changes that are affected by more than.one land-use activity and that are influenced by.processes involving the generation or transport.of water. Almost all environmental changes are.cumulative effects, and almost all land-use.activities contribute to cumulative effects

  12. Original and cumulative prospect theory: a discussion of empirical differences

    NARCIS (Netherlands)

    Wakker, P.P.; Fennema, H.

    1997-01-01

    This note discusses differences between prospect theory and cumulative prospect theory. It shows that cumulative prospect theory is not merely a formal correction of some theoretical problems in prospect theory, but it also gives different predictions. Experiments are described that favor cumulative

  13. Cumulative Environmental Management Association : Wood Buffalo Region

    International Nuclear Information System (INIS)

    Friesen, B.

    2001-01-01

    The recently announced oil sands development of the Wood Buffalo Region in Alberta was the focus of this power point presentation. Both mining and in situ development is expected to total $26 billion and 2.6 million barrels per day of bitumen production. This paper described the economic, social and environmental challenges facing the resource development of this region. In addition to the proposed oil sands projects, this region will accommodate the needs of conventional oil and gas production, forestry, building of pipelines and power lines, municipal development, recreation, tourism, mining exploration and open cast mining. The Cumulative Environmental Management Association (CEMA) was inaugurated as a non-profit association in April 2000, and includes 41 members from all sectors. Its major role is to ensure a sustainable ecosystem and to avoid any cumulative impacts on wildlife. Other work underway includes the study of soil and plant species diversity, and the effects of air emissions on human health, wildlife and vegetation. The bioaccumulation of heavy metals and their impacts on surface water and fish is also under consideration to ensure the quality and quantity of surface water and ground water. 3 figs

  14. Calculate the maximum expected dose for technical radio physicists a cobalt machine

    International Nuclear Information System (INIS)

    Avila Avila, Rafael; Perez Velasquez, Reytel; Gonzalez Lapez, Nadia

    2009-01-01

    Considering the daily operations carried out by technicians Radiophysics Medical Service Department of Radiation Oncology Hospital V. General Teaching I. Lenin in the city of Holguin, during a working week (Between Monday and Friday) as an important element in calculating the maximum expected dose (MDE). From the exponential decay law which is subject the source activity, we propose corrections to the cumulative doses in the weekly period, leading to obtaining a formula which takes into a cumulative dose during working days and sees no dose accumulation of rest days (Saturday and Sunday). The estimate factor correction is made from a power series expansion convergent is truncated at the n-th term coincides with the week period for which you want to calculate the dose. As initial condition is adopted ambient dose equivalent rate as a given, which allows estimate MDE in the moments after or before this. Calculations were proposed use of an Excel spreadsheet that allows simple and accessible processing the formula obtained. (author)

  15. Dose from radiological examinations

    International Nuclear Information System (INIS)

    Imamura, Keiko; Uji, Teruyuki; Sakuyama, Keiko; Fujikawa, Mitsuhiro; Fujii, Masamichi

    1976-01-01

    Relatively high gonad doses, several hundred to one thousand mR, have been observed in case of pelvis, hip-joint, coccyx, lower abdomen and lumber examination. Dose to the ovary is especially high in barium enema and I.V.P. examinations. About 12 per cent of the 4-ray examination are high-dose. The gonad dose is relatively high in examination of abdomen and lower extremities, in infants. The dose to the eyes is especially high, 1.0 to 2.5R per exposure, in temporal bone and nasal sinuses tomography. X-ray doses have been compared with dose limits recommended by ICRP and with the gonad dose from natural radiations. The gonad dose in lumbar examination, barium enema, I.V.P. etc. is as high as the maximum permissible dose per year recommended by ICRP. Several devices have been made for dose reduction in the daily examinations: (1) separating the radiation field from the gonad by one centimeter decreases the gonad dose about one-half. (2) using sensitive screens and films. In pelvimetry and in infant hip-joint examination, the most sensitive screen and film are used. In the I.V.P. examination of adult, use of MS screen in place of FS screen decreases the dose to one-third, in combination with careful setting of radiation field, (3) use of grid increases the dose about 50 percent and the lead rubber protection (0.1mm lead equivalent) decreases the gonad dose to one-thirtieth in the spinal column examination of infant, (4) A lead protector, 1mm thickness and 2.5cm in diameter, on the eyes decreases the dose to about one-eighth in the face and nead examinations. These simple and effective methods for dose reduction. Should be carried out in as many examinations as possible in addition to observing dose limits recommended by ICRP. (Evans, J.)

  16. Cumulative ionizing radiation exposure in patients with end stage kidney disease: a 6-year retrospective analysis.

    LENUS (Irish Health Repository)

    Coyle, Joe

    2011-08-13

    OBJECTIVE: To quantify cumulative exposure to ionizing radiation in patients with end stage kidney disease (ESKD). To investigate factors which may be independently associated with risk of high cumulative effective dose (CED). MATERIALS AND METHODS: The study had local institutional review board ethical approval. We conducted a retrospective study of 394 period prevalent ESKD patients attending a single tertiary referral centre between 2004 and 2009. Patient demographics were obtained from case records. Details of radiological investigations were obtained from the institutional radiology computerized database. CED was calculated using standard procedure specific radiation levels. High exposure was defined as CED > 50 mSv, an exposure which has been reported to increase cancer mortality by 5%. Data were compared using Pearson χ(2) and Mann-Whitney U test or Kruskal-Wallis tests. RESULTS: 394 patients were followed for a median of 4 years (1518 patient years follow-up). Of these 63% were male. Seventeen percent of patients had a CED of >50 mSv. Computed tomography (CT) accounted for 9% of total radiological studies\\/procedures while contributing 61.4% of total study dose. Median cumulative dose and median dose per patient year were significantly higher in the hemodialysis (HD) group (15.13 and 5.79 mSv, respectively) compared to the post-transplant group (2.9 and 0.52 mSv, respectively) (P < 0.001). CONCLUSION: ESKD patients are at risk of cumulative exposure to significant levels of diagnostic radiation. The majority of this exposure is imparted as a result of CT examinations to patients in the HD group.

  17. Evolution model with a cumulative feedback coupling

    Science.gov (United States)

    Trimper, Steffen; Zabrocki, Knud; Schulz, Michael

    2002-05-01

    The paper is concerned with a toy model that generalizes the standard Lotka-Volterra equation for a certain population by introducing a competition between instantaneous and accumulative, history-dependent nonlinear feedback the origin of which could be a contribution from any kind of mismanagement in the past. The results depend on the sign of that additional cumulative loss or gain term of strength λ. In case of a positive coupling the system offers a maximum gain achieved after a finite time but the population will die out in the long time limit. In this case the instantaneous loss term of strength u is irrelevant and the model exhibits an exact solution. In the opposite case λ<0 the time evolution of the system is terminated in a crash after ts provided u=0. This singularity after a finite time can be avoided if u≠0. The approach may well be of relevance for the qualitative understanding of more realistic descriptions.

  18. Psychometric properties of the Cumulated Ambulation Score

    DEFF Research Database (Denmark)

    Ferriero, Giorgio; Kristensen, Morten T; Invernizzi, Marco

    2018-01-01

    INTRODUCTION: In the geriatric population, independent mobility is a key factor in determining readiness for discharge following acute hospitalization. The Cumulated Ambulation Score (CAS) is a potentially valuable score that allows day-to-day measurements of basic mobility. The CAS was developed...... and validated in older patients with hip fracture as an early postoperative predictor of short-term outcome, but it is also used to assess geriatric in-patients with acute medical illness. Despite the fast- accumulating literature on the CAS, to date no systematic review synthesizing its psychometric properties....... Of 49 studies identified, 17 examined the psychometric properties of the CAS. EVIDENCE SYNTHESIS: Most papers dealt with patients after hip fracture surgery, and only 4 studies assessed the CAS psychometric characteristics also in geriatric in-patients with acute medical illness. Two versions of CAS...

  19. Transmission fidelity is the key to the build-up of cumulative culture.

    Science.gov (United States)

    Lewis, Hannah M; Laland, Kevin N

    2012-08-05

    Many animals have socially transmitted behavioural traditions, but human culture appears unique in that it is cumulative, i.e. human cultural traits increase in diversity and complexity over time. It is often suggested that high-fidelity cultural transmission is necessary for cumulative culture to occur through refinement, a process known as 'ratcheting', but this hypothesis has never been formally evaluated. We discuss processes of information transmission and loss of traits from a cognitive viewpoint alongside other cultural processes of novel invention (generation of entirely new traits), modification (refinement of existing traits) and combination (bringing together two established traits to generate a new trait). We develop a simple cultural transmission model that does not assume major evolutionary changes (e.g. in brain architecture) and show that small changes in the fidelity with which information is passed between individuals can lead to cumulative culture. In comparison, modification and combination have a lesser influence on, and novel invention appears unimportant to, the ratcheting process. Our findings support the idea that high-fidelity transmission is the key driver of human cumulative culture, and that progress in cumulative culture depends more on trait combination than novel invention or trait modification.

  20. Lead poisoning

    Science.gov (United States)

    ... drinking water in homes containing pipes that were connected with lead solder . Although new building codes require ... lead in their bodies when they put lead objects in their mouths, especially if they swallow those ...

  1. Lead Poisoning

    Science.gov (United States)

    Lead is a metal that occurs naturally in the earth's crust. Lead can be found in all parts of our ... from human activities such as mining and manufacturing. Lead used to be in paint; older houses may ...

  2. The cumulative effect of air pollutants on the acute exacerbation of COPD in Shanghai, China.

    Science.gov (United States)

    Sun, Xian Wen; Chen, Pei Li; Ren, Lei; Lin, Ying Ni; Zhou, Jian Ping; Ni, Lei; Li, Qing Yun

    2018-05-01

    Epidemiologic studies have shown the effect of air pollutants on acute exacerbation of chronic obstructive pulmonary disease (AECOPD). However, little is known regarding the dose-response relationship. This study aimed to investigate the cumulative effect of air pollutants on AECOPD. We collected 101 patients with AECOPD from November 2010 through August 2011 in Shanghai. Multiple logistic regression was used to estimate associations between air pollutants and AECOPD. Poisson regression was then applied to determine the cumulative effect of air pollutants including particulate matter 10 (PM10), PM2.5, nitrogen dioxide (NO 2 ), sulphur dioxide (SO 2 ) and ozone (O 3 ) on AECOPD, of which the seasonal variation was further explored. The monthly episodes of AECOPD were associated with the concentrations of PM2.5 (r=0.884, peffect in cold season, whereas 7days in warm season. The RR for AECOPD for per 10μg/m 3 increment in NO 2 was 1.07, with a 5-day cumulative effect without seasonal variation. High consecutive levels of PM2.5 and NO 2 increase the risk of developing AECOPD. Cumulative effect of PM2.5 and NO 2 appears before the exacerbation onset. These gradations were more evident in the PM2.5 during different seasons. Copyright © 2017 Elsevier B.V. All rights reserved.

  3. 7 CFR 42.132 - Determining cumulative sum values.

    Science.gov (United States)

    2010-01-01

    ... 7 Agriculture 2 2010-01-01 2010-01-01 false Determining cumulative sum values. 42.132 Section 42... Determining cumulative sum values. (a) The parameters for the on-line cumulative sum sampling plans for AQL's... 3 1 2.5 3 1 2 1 (b) At the beginning of the basic inspection period, the CuSum value is set equal to...

  4. Improving cumulative effects assessment in Alberta: Regional strategic assessment

    International Nuclear Information System (INIS)

    Johnson, Dallas; Lalonde, Kim; McEachern, Menzie; Kenney, John; Mendoza, Gustavo; Buffin, Andrew; Rich, Kate

    2011-01-01

    The Government of Alberta, Canada is developing a regulatory framework to better manage cumulative environmental effects from development in the province. A key component of this effort is regional planning, which will lay the primary foundation for cumulative effects management into the future. Alberta Environment has considered the information needs of regional planning and has concluded that Regional Strategic Assessment may offer significant advantages if integrated into the planning process, including the overall improvement of cumulative environmental effects assessment in the province.

  5. Radiation dose in vertebroplasty

    International Nuclear Information System (INIS)

    Mehdizade, A.; Lovblad, K.O.; Wilhelm, K.E.; Somon, T.; Wetzel, S.G.; Kelekis, A.D.; Yilmaz, H.; Abdo, G.; Martin, J.B.; Viera, J.M.; Ruefenacht, D.A.

    2004-01-01

    We wished to measure the absorbed radiation dose during fluoroscopically controlled vertebroplasty and to assess the possibility of deterministic radiation effects to the operator. The dose was measured in 11 consecutive procedures using thermoluminescent ring dosimeters on the hand of the operator and electronic dosimeters inside and outside of the operator's lead apron. We found doses of 0.022-3.256 mGy outside and 0.01-0.47 mGy inside the lead apron. Doses on the hand were higher, 0.5-8.5 mGy. This preliminary study indicates greater exposure to the operator's hands than expected from traditional apron measurements. (orig.)

  6. Standardization of the cumulative absolute velocity

    International Nuclear Information System (INIS)

    O'Hara, T.F.; Jacobson, J.P.

    1991-12-01

    EPRI NP-5930, ''A Criterion for Determining Exceedance of the Operating Basis Earthquake,'' was published in July 1988. As defined in that report, the Operating Basis Earthquake (OBE) is exceeded when both a response spectrum parameter and a second damage parameter, referred to as the Cumulative Absolute Velocity (CAV), are exceeded. In the review process of the above report, it was noted that the calculation of CAV could be confounded by time history records of long duration containing low (nondamaging) acceleration. Therefore, it is necessary to standardize the method of calculating CAV to account for record length. This standardized methodology allows consistent comparisons between future CAV calculations and the adjusted CAV threshold value based upon applying the standardized methodology to the data set presented in EPRI NP-5930. The recommended method to standardize the CAV calculation is to window its calculation on a second-by-second basis for a given time history. If the absolute acceleration exceeds 0.025g at any time during each one second interval, the earthquake records used in EPRI NP-5930 have been reanalyzed and the adjusted threshold of damage for CAV was found to be 0.16g-set

  7. Analysis of Memory Codes and Cumulative Rehearsal in Observational Learning

    Science.gov (United States)

    Bandura, Albert; And Others

    1974-01-01

    The present study examined the influence of memory codes varying in meaningfulness and retrievability and cumulative rehearsal on retention of observationally learned responses over increasing temporal intervals. (Editor)

  8. Lead poisoning

    Energy Technology Data Exchange (ETDEWEB)

    Beijers, J A

    1952-01-01

    Three cases of acute lead poisoning of cattle herds via ingestion are reported, and reference is made to several other incidents of lead in both humans and animals. The quantity of lead which was found in the livers of the dead cows varied from 6.5 to 19 mg/kg, while 1160 mg/kg of lead in the liver was found for a young cow which was poisoned experimentally with 5 gms of lead acetate per day; hence, there appears to be great variability in the amounts deposited that can lead to intoxication and death. No evidence was found for a lead seam around the teeth, prophyrinuria, or basophil granules in the erythrocytes during acute or chronic lead poisoning of cattle or horses examined. Reference is made to attempts of finding the boundary line between increased lead absorption and lead intoxication in humans, and an examination of 60 laborers in an offset-printing office containing a great deal of inhalable lead (0.16 to 1.9 mg/cu m air) is reviewed. Physical deviation, basophylic granulation of erythrocytes, increased lead content of the urine, and porphyrinuria only indicate an increased absorption of lead; the use of the term intoxication is justified if, in addition, there are complaints of lack of appetite, constipation, fatigue, abdominal pain, and emaciation.

  9. Lead Toxicity

    Science.gov (United States)

    ... o Do not use glazed ceramics, home remedies, cosmetics, or leaded-crystal glassware unless you know that they are lead safe. o If you live near an industry, mine, or waste site that may have contaminated ...

  10. Relational Leading

    DEFF Research Database (Denmark)

    Larsen, Mette Vinther; Rasmussen, Jørgen Gulddahl

    2015-01-01

    This first chapter presents the exploratory and curious approach to leading as relational processes – an approach that pervades the entire book. We explore leading from a perspective that emphasises the unpredictable challenges and triviality of everyday life, which we consider an interesting......, relevant and realistic way to examine leading. The chapter brings up a number of concepts and contexts as formulated by researchers within the field, and in this way seeks to construct a first understanding of relational leading....

  11. Cumulative Effect of Depression on Dementia Risk

    Directory of Open Access Journals (Sweden)

    J. Olazarán

    2013-01-01

    Full Text Available Objective. To analyze a potential cumulative effect of life-time depression on dementia and Alzheimer’s disease (AD, with control of vascular factors (VFs. Methods. This study was a subanalysis of the Neurological Disorders in Central Spain (NEDICES study. Past and present depression, VFs, dementia status, and dementia due to AD were documented at study inception. Dementia status was also documented after three years. Four groups were created according to baseline data: never depression (nD, past depression (pD, present depression (prD, and present and past depression (prpD. Logistic regression was used. Results. Data of 1,807 subjects were investigated at baseline (mean age 74.3, 59.3% women, and 1,376 (81.6% subjects were evaluated after three years. The prevalence of dementia at baseline was 6.7%, and dementia incidence was 6.3%. An effect of depression was observed on dementia prevalence (OR [CI 95%] 1.84 [1.01–3.35] for prD and 2.73 [1.08–6.87] for prpD, and on dementia due to AD (OR 1.98 [0.98–3.99] for prD and OR 3.98 [1.48–10.71] for prpD (fully adjusted models, nD as reference. Depression did not influence dementia incidence. Conclusions. Present depression and, particularly, present and past depression are associated with dementia at old age. Multiple mechanisms, including toxic effect of depression on hippocampal neurons, plausibly explain these associations.

  12. Quantitative cumulative biodistribution of antibodies in mice

    Science.gov (United States)

    Yip, Victor; Palma, Enzo; Tesar, Devin B; Mundo, Eduardo E; Bumbaca, Daniela; Torres, Elizabeth K; Reyes, Noe A; Shen, Ben Q; Fielder, Paul J; Prabhu, Saileta; Khawli, Leslie A; Boswell, C Andrew

    2014-01-01

    The neonatal Fc receptor (FcRn) plays an important and well-known role in antibody recycling in endothelial and hematopoietic cells and thus it influences the systemic pharmacokinetics (PK) of immunoglobulin G (IgG). However, considerably less is known about FcRn’s role in the metabolism of IgG within individual tissues after intravenous administration. To elucidate the organ distribution and gain insight into the metabolism of humanized IgG1 antibodies with different binding affinities FcRn, comparative biodistribution studies in normal CD-1 mice were conducted. Here, we generated variants of herpes simplex virus glycoprotein D-specific antibody (humanized anti-gD) with increased and decreased FcRn binding affinity by genetic engineering without affecting antigen specificity. These antibodies were expressed in Chinese hamster ovary cell lines, purified and paired radiolabeled with iodine-125 and indium-111. Equal amounts of I-125-labeled and In-111-labeled antibodies were mixed and intravenously administered into mice at 5 mg/kg. This approach allowed us to measure both the real-time IgG uptake (I-125) and cumulative uptake of IgG and catabolites (In-111) in individual tissues up to 1 week post-injection. The PK and distribution of the wild-type IgG and the variant with enhanced binding for FcRn were largely similar to each other, but vastly different for the rapidly cleared low-FcRn-binding variant. Uptake in individual tissues varied across time, FcRn binding affinity, and radiolabeling method. The liver and spleen emerged as the most concentrated sites of IgG catabolism in the absence of FcRn protection. These data provide an increased understanding of FcRn’s role in antibody PK and catabolism at the tissue level. PMID:24572100

  13. Lead Test

    Science.gov (United States)

    ... to do renovation and repair projects using lead-safe work practices to avoid creating more lead dust or ... in a dangerous area? Yes. If you are working in a potentially harmful environment with exposure to lead dust or fumes: Wash ...

  14. Analysis of cumulative exergy losses in the chains of technological processes

    International Nuclear Information System (INIS)

    Szargut, J.

    1989-01-01

    This paper reports on cumulative exergy consumption (CExC) which characterizes the chain of technological processes leading from natural resources to the final product under consideration. The difference of CExC and exergy of material or energy carrier expresses the cumulative exergy loss (CExL) in the mentioned technological chain. Two apportionment methods of CExL have been proposed. Partial exergy losses appear in particular links of the technological chain and characterize the influence of irreversibility of these links. Constituent exergy losses express the influence of thermodynamic imperfection of constituent technological chains leading to the final link of the total technological chain. Analysis of the partial and constituent exergy losses informs about the possibilities of improvement of the technological chains

  15. A Framework for Treating Cumulative Trauma with Art Therapy

    Science.gov (United States)

    Naff, Kristina

    2014-01-01

    Cumulative trauma is relatively undocumented in art therapy practice, although there is growing evidence that art therapy provides distinct benefits for resolving various traumas. This qualitative study proposes an art therapy treatment framework for cumulative trauma derived from semi-structured interviews with three art therapists and artistic…

  16. Cumulative effect in multiple production processes on nuclei

    International Nuclear Information System (INIS)

    Golubyatnikova, E.S.; Shmonin, V.L.; Kalinkin, B.N.

    1989-01-01

    It is shown that the cumulative effect is a natural result of the process of hadron multiple production in nuclear reactions. Interpretation is made of the universality of slopes of inclusive spectra and other characteristics of cumulative hadrons. The character of information from such reactions is discussed, which could be helpful in studying the mechanism of multiparticle production. 27 refs.; 4 figs

  17. Cumulative particle production in the quark recombination model

    International Nuclear Information System (INIS)

    Gavrilov, V.B.; Leksin, G.A.

    1987-01-01

    Production of cumulative particles in hadron-nuclear inteactions at high energies is considered within the framework of recombination quark model. Predictions for inclusive cross sections of production of cumulative particles and different resonances containing quarks in s state are made

  18. High cumulants of conserved charges and their statistical uncertainties

    Science.gov (United States)

    Li-Zhu, Chen; Ye-Yin, Zhao; Xue, Pan; Zhi-Ming, Li; Yuan-Fang, Wu

    2017-10-01

    We study the influence of measured high cumulants of conserved charges on their associated statistical uncertainties in relativistic heavy-ion collisions. With a given number of events, the measured cumulants randomly fluctuate with an approximately normal distribution, while the estimated statistical uncertainties are found to be correlated with corresponding values of the obtained cumulants. Generally, with a given number of events, the larger the cumulants we measure, the larger the statistical uncertainties that are estimated. The error-weighted averaged cumulants are dependent on statistics. Despite this effect, however, it is found that the three sigma rule of thumb is still applicable when the statistics are above one million. Supported by NSFC (11405088, 11521064, 11647093), Major State Basic Research Development Program of China (2014CB845402) and Ministry of Science and Technology (MoST) (2016YFE0104800)

  19. Radiation dose monitoring in the clinical routine

    Energy Technology Data Exchange (ETDEWEB)

    Guberina, Nika [UK Essen (Germany). Radiology

    2017-04-15

    Here we describe the first clinical experiences regarding the use of an automated radiation dose management software to monitor the radiation dose of patients during routine examinations. Many software solutions for monitoring radiation dose have emerged in the last decade. The continuous progress in radiological techniques, new scan features, scanner generations and protocols are the primary challenge for radiation dose monitoring software systems. To simulate valid dose calculations, radiation dose monitoring systems have to follow current trends and stay constantly up-to-date. The dose management software is connected to all devices at our institute and conducts automatic data acquisition and radiation dose calculation. The system incorporates 18 virtual phantoms based on the Cristy phantom family, estimating doses in newborns to adults. Dose calculation relies on a Monte Carlo simulation engine. Our first practical experiences demonstrate that the software is capable of dose estimation in the clinical routine. Its implementation and use have some limitations that can be overcome. The software is promising and allows assessment of radiation doses, like organ and effective doses according to ICRP 60 and ICRP 103, patient radiation dose history and cumulative radiation doses. Furthermore, we are able to determine local diagnostic reference doses. The radiation dose monitoring software systems can facilitate networking between hospitals and radiological departments, thus refining radiation doses and implementing reference doses at substantially lower levels.

  20. Internal dose estimates

    International Nuclear Information System (INIS)

    Wrenn, M.E.

    1977-01-01

    Internal doses, the procedures for making them and their significance has been reviewed. Effects of uranium, radium, lead-210, polonium-210, thorium in man are analysed based on data from tables and plots. Dosimetry of some ingested nuclides and inhalation dose due to radon-222, radon-220 and their daugther products are discussed [pt

  1. Towards Greenland Glaciation: cumulative or abrupt transition?

    Science.gov (United States)

    Ramstein, Gilles; Tan, Ning; Ladant, Jean-baptiste; Dumas, Christophe; Contoux, Camille

    2017-04-01

    During the mid-Pliocene warming period (3-3.3 Ma BP), the global annual mean temperatures inferred by data and model studies were 2-3° warmer than pre-industrial values. Accordingly, Greenland ice sheet volume is supposed to reach at the most, only half of that of present-day [Haywood et al. 2010]. Around 2.7-2.6 Ma BP, just ˜ 500 kyr after the warming peak of mid-Pliocene, the Greenland ice sheet has reached its full size [Lunt et al. 2008]. A crucial question concerns the evolution of the Greenland ice sheet from half to full size during the 3 - 2.5 Ma period. Data show a decreasing trend of atmospheric CO2 concentration from 3 Ma to 2.5 Ma [Seki et al.2010; Bartoli et al. 2011; Martinez et al. 2015]. However, a recent study [Contoux et al. 2015] suggests that a lowering of CO2 is not sufficient to initiate a perennial glaciation on Greenland and must be combined with low summer insolation to preserve the ice sheet during insolation maxima. This suggests rather a cumulative process than an abrupt event. In order to diagnose the evolution of the ice sheet build-up, we carry on, for the first time, a transient simulation of climate and ice sheet evolutions from 3 Ma to 2.5 Ma. This strategy enables us to investigate the waxing and waning of the ice sheet during several orbital cycles. We use a tri-dimensional interpolation method designed by Ladant et al. (2014), which allows the evolution of CO2 concentration and of orbital parameters, and the evolution of the Greenland ice sheet size to be taken into account. By interpolating climatic snapshot simulations ran with various possible combinations of CO2, orbits and ice sheet sizes, we can build a continuous climatic forcing that is then used to provide 500 kyrs-long ice sheet simulations. With such a tool, we may offer a physically based answer to different CO2 reconstructions scenarios and analyse which one is the most consistent with Greenland ice sheet buildup.

  2. Dose gradient curve: A new tool for evaluating dose gradient.

    Science.gov (United States)

    Sung, KiHoon; Choi, Young Eun

    2018-01-01

    Stereotactic radiotherapy, which delivers an ablative high radiation dose to a target volume for maximum local tumor control, requires a rapid dose fall-off outside the target volume to prevent extensive damage to nearby normal tissue. Currently, there is no tool to comprehensively evaluate the dose gradient near the target volume. We propose the dose gradient curve (DGC) as a new tool to evaluate the quality of a treatment plan with respect to the dose fall-off characteristics. The average distance between two isodose surfaces was represented by the dose gradient index (DGI) estimated by a simple equation using the volume and surface area of isodose levels. The surface area was calculated by mesh generation and surface triangulation. The DGC was defined as a plot of the DGI of each dose interval as a function of the dose. Two types of DGCs, differential and cumulative, were generated. The performance of the DGC was evaluated using stereotactic radiosurgery plans for virtual targets. Over the range of dose distributions, the dose gradient of each dose interval was well-characterized by the DGC in an easily understandable graph format. Significant changes in the DGC were observed reflecting the differences in planning situations and various prescription doses. The DGC is a rational method for visualizing the dose gradient as the average distance between two isodose surfaces; the shorter the distance, the steeper the dose gradient. By combining the DGC with the dose-volume histogram (DVH) in a single plot, the DGC can be utilized to evaluate not only the dose gradient but also the target coverage in routine clinical practice.

  3. High selection pressure promotes increase in cumulative adaptive culture.

    Directory of Open Access Journals (Sweden)

    Carolin Vegvari

    Full Text Available The evolution of cumulative adaptive culture has received widespread interest in recent years, especially the factors promoting its occurrence. Current evolutionary models suggest that an increase in population size may lead to an increase in cultural complexity via a higher rate of cultural transmission and innovation. However, relatively little attention has been paid to the role of natural selection in the evolution of cultural complexity. Here we use an agent-based simulation model to demonstrate that high selection pressure in the form of resource pressure promotes the accumulation of adaptive culture in spite of small population sizes and high innovation costs. We argue that the interaction of demography and selection is important, and that neither can be considered in isolation. We predict that an increase in cultural complexity is most likely to occur under conditions of population pressure relative to resource availability. Our model may help to explain why culture change can occur without major environmental change. We suggest that understanding the interaction between shifting selective pressures and demography is essential for explaining the evolution of cultural complexity.

  4. Correlated stopping, proton clusters and higher order proton cumulants

    Energy Technology Data Exchange (ETDEWEB)

    Bzdak, Adam [AGH University of Science and Technology, Faculty of Physics and Applied Computer Science, Krakow (Poland); Koch, Volker [Lawrence Berkeley National Laboratory, Nuclear Science Division, Berkeley, CA (United States); Skokov, Vladimir [RIKEN/BNL, Brookhaven National Laboratory, Upton, NY (United States)

    2017-05-15

    We investigate possible effects of correlations between stopped nucleons on higher order proton cumulants at low energy heavy-ion collisions. We find that fluctuations of the number of wounded nucleons N{sub part} lead to rather nontrivial dependence of the correlations on the centrality; however, this effect is too small to explain the large and positive four-proton correlations found in the preliminary data collected by the STAR collaboration at √(s) = 7.7 GeV. We further demonstrate that, by taking into account additional proton clustering, we are able to qualitatively reproduce the preliminary experimental data. We speculate that this clustering may originate either from collective/multi-collision stopping which is expected to be effective at lower energies or from a possible first-order phase transition, or from (attractive) final state interactions. To test these ideas we propose to measure a mixed multi-particle correlation between stopped protons and a produced particle (e.g. pion, antiproton). (orig.)

  5. An Analysis of Cumulative Risks Indicated by Biomonitoring Data of Six Phthalates Using the Maximum Cumulative Ratio

    Science.gov (United States)

    The Maximum Cumulative Ratio (MCR) quantifies the degree to which a single component of a chemical mixture drives the cumulative risk of a receptor.1 This study used the MCR, the Hazard Index (HI) and Hazard Quotient (HQ) to evaluate co-exposures to six phthalates using biomonito...

  6. An analysis of cumulative risks based on biomonitoring data for six phthalates using the Maximum Cumulative Ratio

    Science.gov (United States)

    The Maximum Cumulative Ratio (MCR) quantifies the degree to which a single chemical drives the cumulative risk of an individual exposed to multiple chemicals. Phthalates are a class of chemicals with ubiquitous exposures in the general population that have the potential to cause ...

  7. Dose estimation from residual and fallout radioactivity, 1

    International Nuclear Information System (INIS)

    Takeshita, Kenji

    1975-01-01

    External dose rates and cumulative doses for early entrants from areal surveys and simulated experiments are reviewed. The average cumulative doses to infinity at the hypocenters were 101 rad in Hiroshima and 32 rad in Nagasaki, with a variation of about 60 percent. Radioactive fallout areas nearly matched the ''black rain'' areas in Nagasaki and in Hiroshima. Radioactivity in the fallout areas was affected by radioactive decay and by the leaching and dissipation by rains. Considering these factors, the cumulative dose to infinity in the fallout area of Hiroshima was estimated to be 13 rad, excluding internal radiation doses from inhaled and ingested radionuclides. Attempts to estimate radiation dose from internally deposited radionuclides are also described. (auth.)

  8. Dose sculpting with generalized equivalent uniform dose

    International Nuclear Information System (INIS)

    Wu Qiuwen; Djajaputra, David; Liu, Helen H.; Dong Lei; Mohan, Radhe; Wu, Yan

    2005-01-01

    With intensity-modulated radiotherapy (IMRT), a variety of user-defined dose distribution can be produced using inverse planning. The generalized equivalent uniform dose (gEUD) has been used in IMRT optimization as an alternative objective function to the conventional dose-volume-based criteria. The purpose of this study was to investigate the effectiveness of gEUD optimization to fine tune the dose distributions of IMRT plans. We analyzed the effect of gEUD-based optimization parameters on plan quality. The objective was to determine whether dose distribution to selected structures could be improved using gEUD optimization without adversely altering the doses delivered to other structures, as in sculpting. We hypothesized that by carefully defining gEUD parameters (EUD 0 and n) based on the current dose distributions, the optimization system could be instructed to search for alternative solutions in the neighborhood, and we could maintain the dose distributions for structures already satisfactory and improve dose for structures that need enhancement. We started with an already acceptable IMRT plan optimized with any objective function. The dose distribution was analyzed first. For structures that dose should not be changed, a higher value of n was used and EUD 0 was set slightly higher/lower than the EUD value at the current dose distribution for critical structures/targets. For structures that needed improvement in dose, a higher to medium value of n was used, and EUD 0 was set to the EUD value or slightly lower/higher for the critical structure/target at the current dose distribution. We evaluated this method in one clinical case each of head and neck, lung and prostate cancer. Dose volume histograms, isodose distributions, and relevant tolerance doses for critical structures were used for the assessment. We found that by adjusting gEUD optimization parameters, the dose distribution could be improved with only a few iterations. A larger value of n could lead to

  9. Cumulative stress and autonomic dysregulation in a community sample.

    Science.gov (United States)

    Lampert, Rachel; Tuit, Keri; Hong, Kwang-Ik; Donovan, Theresa; Lee, Forrester; Sinha, Rajita

    2016-05-01

    Whether cumulative stress, including both chronic stress and adverse life events, is associated with decreased heart rate variability (HRV), a non-invasive measure of autonomic status which predicts poor cardiovascular outcomes, is unknown. Healthy community dwelling volunteers (N = 157, mean age 29 years) participated in the Cumulative Stress/Adversity Interview (CAI), a 140-item event interview measuring cumulative adversity including major life events, life trauma, recent life events and chronic stressors, and underwent 24-h ambulatory ECG monitoring. HRV was analyzed in the frequency domain and standard deviation of NN intervals (SDNN) calculated. Initial simple regression analyses revealed that total cumulative stress score, chronic stressors and cumulative adverse life events (CALE) were all inversely associated with ultra low-frequency (ULF), very low-frequency (VLF) and low-frequency (LF) power and SDNN (all p accounting for additional appreciable variance. For VLF and LF, both total cumulative stress and chronic stress significantly contributed to the variance alone but were not longer significant after adjusting for race and health behaviors. In summary, total cumulative stress, and its components of adverse life events and chronic stress were associated with decreased cardiac autonomic function as measured by HRV. Findings suggest one potential mechanism by which stress may exert adverse effects on mortality in healthy individuals. Primary preventive strategies including stress management may prove beneficial.

  10. Leading Democratically

    Science.gov (United States)

    Brookfield, Stephen

    2010-01-01

    Democracy is the most venerated of American ideas, the one for which wars are fought and people die. So most people would probably agree that leaders should be able to lead well in a democratic society. Yet, genuinely democratic leadership is a relative rarity. Leading democratically means viewing leadership as a function or process, rather than…

  11. Cumulants in perturbation expansions for non-equilibrium field theory

    International Nuclear Information System (INIS)

    Fauser, R.

    1995-11-01

    The formulation of perturbation expansions for a quantum field theory of strongly interacting systems in a general non-equilibrium state is discussed. Non-vanishing initial correlations are included in the formulation of the perturbation expansion in terms of cumulants. The cumulants are shown to be the suitable candidate for summing up the perturbation expansion. Also a linked-cluster theorem for the perturbation series with cumulants is presented. Finally a generating functional of the perturbation series with initial correlations is studied. We apply the methods to a simple model of a fermion-boson system. (orig.)

  12. Estimating a population cumulative incidence under calendar time trends

    DEFF Research Database (Denmark)

    Hansen, Stefan N; Overgaard, Morten; Andersen, Per K

    2017-01-01

    BACKGROUND: The risk of a disease or psychiatric disorder is frequently measured by the age-specific cumulative incidence. Cumulative incidence estimates are often derived in cohort studies with individuals recruited over calendar time and with the end of follow-up governed by a specific date....... It is common practice to apply the Kaplan-Meier or Aalen-Johansen estimator to the total sample and report either the estimated cumulative incidence curve or just a single point on the curve as a description of the disease risk. METHODS: We argue that, whenever the disease or disorder of interest is influenced...

  13. African Swine Fever Virus Georgia 2007 with a Deletion of Virulence-Associated Gene 9GL (B119L), when Administered at Low Doses, Leads to Virus Attenuation in Swine and Induces an Effective Protection against Homologous Challenge.

    Science.gov (United States)

    O'Donnell, Vivian; Holinka, Lauren G; Krug, Peter W; Gladue, Douglas P; Carlson, Jolene; Sanford, Brenton; Alfano, Marialexia; Kramer, Edward; Lu, Zhiqiang; Arzt, Jonathan; Reese, Bo; Carrillo, Consuelo; Risatti, Guillermo R; Borca, Manuel V

    2015-08-01

    African swine fever virus (ASFV) is the etiological agent of an often lethal disease of domestic pigs. Disease control strategies have been hampered by the unavailability of vaccines against ASFV. Since its introduction in the Republic of Georgia, a highly virulent virus, ASFV Georgia 2007 (ASFV-G), has caused an epizootic that spread rapidly into Eastern European countries. Currently no vaccines are available or under development to control ASFV-G. In the past, genetically modified ASFVs harboring deletions of virulence-associated genes have proven attenuated in swine, inducing protective immunity against challenge with homologous parental viruses. Deletion of the gene 9GL (open reading frame [ORF] B119L) in highly virulent ASFV Malawi-Lil-20/1 produced an attenuated phenotype even when administered to pigs at 10(6) 50% hemadsorption doses (HAD50). Here we report the construction of a genetically modified ASFV-G strain (ASFV-G-Δ9GLv) harboring a deletion of the 9GL (B119L) gene. Like Malawi-Lil-20/1-Δ9GL, ASFV-G-Δ9GL showed limited replication in primary swine macrophages. However, intramuscular inoculation of swine with 10(4) HAD50 of ASFV-G-Δ9GL produced a virulent phenotype that, unlike Malawi-Lil-20/1-Δ9GL, induced a lethal disease in swine like parental ASFV-G. Interestingly, lower doses (10(2) to 10(3) HAD50) of ASFV-G-Δ9GL did not induce a virulent phenotype in swine and when challenged protected pigs against disease. A dose of 10(2) HAD50 of ASFV-G-Δ9GLv conferred partial protection when pigs were challenged at either 21 or 28 days postinfection (dpi). An ASFV-G-Δ9GL HAD50 of 10(3) conferred partial and complete protection at 21 and 28 dpi, respectively. The information provided here adds to our recent report on the first attempts toward experimental vaccines against ASFV-G. The main problem for controlling ASF is the lack of vaccines. Studies on ASFV virulence lead to the production of genetically modified attenuated viruses that induce protection

  14. Cumulative t-link threshold models for the genetic analysis of calving ease scores

    Directory of Open Access Journals (Sweden)

    Tempelman Robert J

    2003-09-01

    Full Text Available Abstract In this study, a hierarchical threshold mixed model based on a cumulative t-link specification for the analysis of ordinal data or more, specifically, calving ease scores, was developed. The validation of this model and the Markov chain Monte Carlo (MCMC algorithm was carried out on simulated data from normally and t4 (i.e. a t-distribution with four degrees of freedom distributed populations using the deviance information criterion (DIC and a pseudo Bayes factor (PBF measure to validate recently proposed model choice criteria. The simulation study indicated that although inference on the degrees of freedom parameter is possible, MCMC mixing was problematic. Nevertheless, the DIC and PBF were validated to be satisfactory measures of model fit to data. A sire and maternal grandsire cumulative t-link model was applied to a calving ease dataset from 8847 Italian Piemontese first parity dams. The cumulative t-link model was shown to lead to posterior means of direct and maternal heritabilities (0.40 ± 0.06, 0.11 ± 0.04 and a direct maternal genetic correlation (-0.58 ± 0.15 that were not different from the corresponding posterior means of the heritabilities (0.42 ± 0.07, 0.14 ± 0.04 and the genetic correlation (-0.55 ± 0.14 inferred under the conventional cumulative probit link threshold model. Furthermore, the correlation (> 0.99 between posterior means of sire progeny merit from the two models suggested no meaningful rerankings. Nevertheless, the cumulative t-link model was decisively chosen as the better fitting model for this calving ease data using DIC and PBF.

  15. Leading change.

    Science.gov (United States)

    2017-02-27

    In response to feedback from nursing, midwifery and other care staff who wanted to understand better how the Leading Change, Adding Value framework applies to them, NHS England has updated its webpage to include practice examples.

  16. Cumulative Environmental Impacts: Science and Policy to Protect Communities.

    Science.gov (United States)

    Solomon, Gina M; Morello-Frosch, Rachel; Zeise, Lauren; Faust, John B

    2016-01-01

    Many communities are located near multiple sources of pollution, including current and former industrial sites, major roadways, and agricultural operations. Populations in such locations are predominantly low-income, with a large percentage of minorities and non-English speakers. These communities face challenges that can affect the health of their residents, including limited access to health care, a shortage of grocery stores, poor housing quality, and a lack of parks and open spaces. Environmental exposures may interact with social stressors, thereby worsening health outcomes. Age, genetic characteristics, and preexisting health conditions increase the risk of adverse health effects from exposure to pollutants. There are existing approaches for characterizing cumulative exposures, cumulative risks, and cumulative health impacts. Although such approaches have merit, they also have significant constraints. New developments in exposure monitoring, mapping, toxicology, and epidemiology, especially when informed by community participation, have the potential to advance the science on cumulative impacts and to improve decision making.

  17. Pesticide Cumulative Risk Assessment: Framework for Screening Analysis

    Science.gov (United States)

    This document provides guidance on how to screen groups of pesticides for cumulative evaluation using a two-step approach: begin with evaluation of available toxicological information and, if necessary, follow up with a risk-based screening approach.

  18. Considering Environmental and Occupational Stressors in Cumulative Risk Assessments

    Science.gov (United States)

    While definitions vary across the global scientific community, cumulative risk assessments (CRAs) typically are described as exhibiting a population focus and analyzing the combined risks posed by multiple stressors. CRAs also may consider risk management alternatives as an anal...

  19. Peer tutors as learning and teaching partners: a cumulative ...

    African Journals Online (AJOL)

    ... paper explores the kinds of development in tutors' thinking and action that are possible when training and development is theoretically informed, coherent, and oriented towards improving practice. Keywords: academic development, academic literacies, cumulative learning, higher education, peer tutoring, writing centres.

  20. CTD Information Guide. Preventing Cumulative Trauma Disorders in the Workplace

    National Research Council Canada - National Science Library

    1992-01-01

    The purpose of this report is to provide Army occupational safety and health (OSH) professionals with a primer that explains the basic principles of ergonomic-hazard recognition for common cumulative trauma disorders...

  1. Dose Estimation from Daily and Weekly Dosimetry Data

    Energy Technology Data Exchange (ETDEWEB)

    Ostrouchov, G.

    2001-11-16

    Statistical analyses of data from epidemiologic studies of workers exposed to radiation have been based on recorded annual radiation doses (yearly dose of record). It is usually assumed that the dose values are known exactly, although it is generally recognized that the data contain uncertainty due to measurement error and bias. In our previous work with weekly data, a probability distribution was used to describe an individual's dose during a specific period of time and statistical methods were developed for estimating it from weekly film dosimetry data. This study showed that the yearly dose of record systematically underestimates doses for Oak Ridge National Laboratory (ORNL) workers. This could result in biased estimates of dose-response coefficients and their standard errors. The results of this evaluation raise serious questions about the suitability of the yearly dose of record for direct use in low-dose studies of nuclear industry workers. Here, we extend our previous work to use full information in Pocket meter data and develop the Data Synthesis for Individual Dose Estimation (DSIDE) methodology. Although the DSIDE methodology in this study is developed in the context of daily and weekly data to produce a cumulative yearly dose estimate, in principle it is completely general and can be extended to other time period and measurement combinations. The new methodology takes into account the ''measurement error'' that is produced by the film and pocket-meter dosimetry systems, the biases introduced by policies that lead to recording left-censored doses as zeros, and other measurement and recording practices. The DSIDE method is applied to a sample of dose histories obtained from hard copy dosimetry records at ORNL for the years 1945 to 1955. First, the rigorous addition of daily pocket-meter information shows that the negative bias is generally more severe than was reported in our work based on weekly film data only, however, the

  2. Dose Estimation from Daily and Weekly Dosimetry Data

    International Nuclear Information System (INIS)

    Ostrouchov, G.

    2001-01-01

    Statistical analyses of data from epidemiologic studies of workers exposed to radiation have been based on recorded annual radiation doses (yearly dose of record). It is usually assumed that the dose values are known exactly, although it is generally recognized that the data contain uncertainty due to measurement error and bias. In our previous work with weekly data, a probability distribution was used to describe an individual's dose during a specific period of time and statistical methods were developed for estimating it from weekly film dosimetry data. This study showed that the yearly dose of record systematically underestimates doses for Oak Ridge National Laboratory (ORNL) workers. This could result in biased estimates of dose-response coefficients and their standard errors. The results of this evaluation raise serious questions about the suitability of the yearly dose of record for direct use in low-dose studies of nuclear industry workers. Here, we extend our previous work to use full information in Pocket meter data and develop the Data Synthesis for Individual Dose Estimation (DSIDE) methodology. Although the DSIDE methodology in this study is developed in the context of daily and weekly data to produce a cumulative yearly dose estimate, in principle it is completely general and can be extended to other time period and measurement combinations. The new methodology takes into account the ''measurement error'' that is produced by the film and pocket-meter dosimetry systems, the biases introduced by policies that lead to recording left-censored doses as zeros, and other measurement and recording practices. The DSIDE method is applied to a sample of dose histories obtained from hard copy dosimetry records at ORNL for the years 1945 to 1955. First, the rigorous addition of daily pocket-meter information shows that the negative bias is generally more severe than was reported in our work based on weekly film data only, however, the amount of bias also varies

  3. Skin barrier integrity and natural moisturising factor levels after cumulative dermal exposure to alkaline agents in atopic dermatitis

    NARCIS (Netherlands)

    Angelova-Fischer, Irena; Dapic, Irena; Hoek, Anne-Karin; Jakasa, Ivone; Fischer, Tobias W.; Zillikens, Detlef; Kezic, Sanja

    2014-01-01

    Dermal exposure to alkaline agents may lead to skin barrier damage and irritant contact dermatitis. The objective of this study was to investigate the effects of cumulative exposure to 0.5% sodium lauryl sulphate (SLS) and 0.15% NaOH on the barrier function and natural moisturising factor (NMF)

  4. Cumulative query method for influenza surveillance using search engine data.

    Science.gov (United States)

    Seo, Dong-Woo; Jo, Min-Woo; Sohn, Chang Hwan; Shin, Soo-Yong; Lee, JaeHo; Yu, Maengsoo; Kim, Won Young; Lim, Kyoung Soo; Lee, Sang-Il

    2014-12-16

    Internet search queries have become an important data source in syndromic surveillance system. However, there is currently no syndromic surveillance system using Internet search query data in South Korea. The objective of this study was to examine correlations between our cumulative query method and national influenza surveillance data. Our study was based on the local search engine, Daum (approximately 25% market share), and influenza-like illness (ILI) data from the Korea Centers for Disease Control and Prevention. A quota sampling survey was conducted with 200 participants to obtain popular queries. We divided the study period into two sets: Set 1 (the 2009/10 epidemiological year for development set 1 and 2010/11 for validation set 1) and Set 2 (2010/11 for development Set 2 and 2011/12 for validation Set 2). Pearson's correlation coefficients were calculated between the Daum data and the ILI data for the development set. We selected the combined queries for which the correlation coefficients were .7 or higher and listed them in descending order. Then, we created a cumulative query method n representing the number of cumulative combined queries in descending order of the correlation coefficient. In validation set 1, 13 cumulative query methods were applied, and 8 had higher correlation coefficients (min=.916, max=.943) than that of the highest single combined query. Further, 11 of 13 cumulative query methods had an r value of ≥.7, but 4 of 13 combined queries had an r value of ≥.7. In validation set 2, 8 of 15 cumulative query methods showed higher correlation coefficients (min=.975, max=.987) than that of the highest single combined query. All 15 cumulative query methods had an r value of ≥.7, but 6 of 15 combined queries had an r value of ≥.7. Cumulative query method showed relatively higher correlation with national influenza surveillance data than combined queries in the development and validation set.

  5. Steps and pips in the history of the cumulative recorder.

    OpenAIRE

    Lattal, Kennon A

    2004-01-01

    From its inception in the 1930s until very recent times, the cumulative recorder was the most widely used measurement instrument in the experimental analysis of behavior. It was an essential instrument in the discovery and analysis of schedules of reinforcement, providing the first real-time analysis of operant response rates and patterns. This review traces the evolution of the cumulative recorder from Skinner's early modified kymographs through various models developed by Skinner and his co...

  6. Mapping Cumulative Impacts of Human Activities on Marine Ecosystems

    OpenAIRE

    , Seaplan

    2018-01-01

    Given the diversity of human uses and natural resources that converge in coastal waters, the potential independent and cumulative impacts of those uses on marine ecosystems are important to consider during ocean planning. This study was designed to support the development and implementation of the 2009 Massachusetts Ocean Management Plan. Its goal was to estimate and visualize the cumulative impacts of human activities on coastal and marine ecosystems in the state and federal waters off of Ma...

  7. Dose measurements in mammography

    International Nuclear Information System (INIS)

    Kainberger, F.; Kallinger, W.

    1977-01-01

    Dose measurements at the mamma during mammography were carried out in the form of direct measurement with thermoluminescent dosimetry. Measurement was done for the in- and outcoming doses at the mamma, the dose exposure of the sternal region and the scattered rays above the symphysis, the latter as parameter for the genetic radiation exposure. As expected, the dose of the smooth radiation used for mammography showed a strong decrease at the outcome point in comparison with the income point. Surprisingly high was the scattered radiation in the sternal region. A corresponding protection by lead plates could be taken into consideration. Extremely low is the scattered radiation above the symphysis. Even measurements with the very sensitive calcium fluoride dosimeters did not reveal any practically important dose in the symphysis region. Most measurement values remained below the determinable dose of 0.3mR. Some maximal values varied in the range of 3-1 mR. (orig.) [de

  8. On the duration and intensity of cumulative advantage competitions

    Science.gov (United States)

    Jiang, Bo; Sun, Liyuan; Figueiredo, Daniel R.; Ribeiro, Bruno; Towsley, Don

    2015-11-01

    Network growth can be framed as a competition for edges among nodes in the network. As with various other social and physical systems, skill (fitness) and luck (random chance) act as fundamental forces driving competition dynamics. In the context of networks, cumulative advantage (CA)—the rich-get-richer effect—is seen as a driving principle governing the edge accumulation process. However, competitions coupled with CA exhibit non-trivial behavior and little is formally known about duration and intensity of CA competitions. By isolating two nodes in an ideal CA competition, we provide a mathematical understanding of how CA exacerbates the role of luck in detriment of skill. We show, for instance, that when nodes start with few edges, an early stroke of luck can place the less skilled in the lead for an extremely long period of time, a phenomenon we call ‘struggle of the fittest’. We prove that duration of a simple skill and luck competition model exhibit power-law tails when CA is present, regardless of skill difference, which is in sharp contrast to the exponential tails when fitness is distinct but CA is absent. We also prove that competition intensity is always upper bounded by an exponential tail, irrespective of CA and skills. Thus, CA competitions can be extremely long (infinite mean, depending on fitness ratio) but almost never very intense. The theoretical results are corroborated by extensive numerical simulations. Our findings have important implications to competitions not only among nodes in networks but also in contexts that leverage socio-physical models embodying CA competitions.

  9. On the duration and intensity of cumulative advantage competitions

    International Nuclear Information System (INIS)

    Jiang, Bo; Towsley, Don; Sun, Liyuan; Figueiredo, Daniel R; Ribeiro, Bruno

    2015-01-01

    Network growth can be framed as a competition for edges among nodes in the network. As with various other social and physical systems, skill (fitness) and luck (random chance) act as fundamental forces driving competition dynamics. In the context of networks, cumulative advantage (CA)—the rich-get-richer effect—is seen as a driving principle governing the edge accumulation process. However, competitions coupled with CA exhibit non-trivial behavior and little is formally known about duration and intensity of CA competitions. By isolating two nodes in an ideal CA competition, we provide a mathematical understanding of how CA exacerbates the role of luck in detriment of skill. We show, for instance, that when nodes start with few edges, an early stroke of luck can place the less skilled in the lead for an extremely long period of time, a phenomenon we call ‘struggle of the fittest’. We prove that duration of a simple skill and luck competition model exhibit power-law tails when CA is present, regardless of skill difference, which is in sharp contrast to the exponential tails when fitness is distinct but CA is absent. We also prove that competition intensity is always upper bounded by an exponential tail, irrespective of CA and skills. Thus, CA competitions can be extremely long (infinite mean, depending on fitness ratio) but almost never very intense. The theoretical results are corroborated by extensive numerical simulations. Our findings have important implications to competitions not only among nodes in networks but also in contexts that leverage socio-physical models embodying CA competitions. (paper)

  10. Downstream cumulative effects of land use on freshwater communities

    Science.gov (United States)

    Kuglerová, L.; Kielstra, B. W.; Moore, D.; Richardson, J. S.

    2015-12-01

    Many streams and rivers are subject to disturbance from intense land use such as urbanization and agriculture, and this is especially obvious for small headwaters. Streams are spatially organized into networks where headwaters represent the tributaries and provide water, nutrients, and organic material to the main stems. Therefore perturbations within the headwaters might be cumulatively carried on downstream. Although we know that the disturbance of headwaters in urban and agricultural landscapes poses threats to downstream river reaches, the magnitude and severity of these changes for ecological communities is less known. We studied stream networks along a gradient of disturbance connected to land use intensity, from urbanized watersheds to watersheds placed in agricultural settings in the Greater Toronto Area. Further, we compared the patterns and processes found in the modified watershed to a control watershed, situated in a forested, less impacted landscape. Preliminary results suggest that hydrological modifications (flash floods), habitat loss (drainage and sewer systems), and water quality issues of small streams in urbanized and agricultural watersheds represent major disturbances and threats for aquatic and riparian biota on local as well as larger spatial scales. For example, communities of riparian plants are dominated by species typical of the land use on adjacent uplands as well as the dominant land use on the upstream contributing area, instead of riparian obligates commonly found in forested watersheds. Further, riparian communities in disturbed environments are dominated by invasive species. The changes in riparian communities are vital for various functions of riparian vegetation. Bank erosion control is suppressed, leading to severe channel transformations and sediment loadings in urbanized watersheds. Food sources for instream biota and thermal regimes are also changed, which further triggers alterations of in-stream biological communities

  11. Developmental immunotoxicology of lead

    International Nuclear Information System (INIS)

    Dietert, Rodney R.; Lee, Ji-Eun; Hussain, Irshad; Piepenbrink, Michael

    2004-01-01

    The heavy metal, lead, is a known developmental immunotoxicant that has been shown to produce immune alterations in humans as well as other species. Unlike many compounds that exert adverse immune effects, lead exposure at low to moderate levels does not produce widespread loss of immune cells. In contrast, changes resulting from lead exposure are subtle at the immune cell population level but, nevertheless, can be functionally dramatic. A hallmark of lead-induced immunotoxicity is a pronounced shift in the balance in T helper cell function toward T helper 2 responses at the expense of T helper 1 functions. This bias alters the nature and range of immune responses that can be produced thereby influencing host susceptibility to various diseases. Immunotoxic responses to lead appear to differ across life stages not only quantitatively with regard to dose response, but also qualitatively in terms of the spectrum of immune alterations. Experimental studies in several lab animal species suggest the latter stages of gestation are a period of considerable sensitivity for lead-induced immunotoxicity. This review describes the basic characteristics of lead-induced immunotoxicity emphasizing experimental animal results. It also provides a framework for the consideration of toxicant exposure effects across life stages. The existence of and probable basis for developmental windows of immune hyper-susceptibility are presented. Finally, the potential for lead to serve as a perinatal risk factor for childhood asthma as well as other diseases is considered

  12. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

    Energy Technology Data Exchange (ETDEWEB)

    Calabrese, Edward J., E-mail: edwardc@schoolph.umass.edu

    2017-04-15

    This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report's Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.

  13. The threshold vs LNT showdown: Dose rate findings exposed flaws in the LNT model part 1. The Russell-Muller debate

    International Nuclear Information System (INIS)

    Calabrese, Edward J.

    2017-01-01

    This paper assesses the discovery of the dose-rate effect in radiation genetics and how it challenged fundamental tenets of the linear non-threshold (LNT) dose response model, including the assumptions that all mutational damage is cumulative and irreversible and that the dose-response is linear at low doses. Newly uncovered historical information also describes how a key 1964 report by the International Commission for Radiological Protection (ICRP) addressed the effects of dose rate in the assessment of genetic risk. This unique story involves assessments by two leading radiation geneticists, Hermann J. Muller and William L. Russell, who independently argued that the report's Genetic Summary Section on dose rate was incorrect while simultaneously offering vastly different views as to what the report's summary should have contained. This paper reveals occurrences of scientific disagreements, how conflicts were resolved, which view(s) prevailed and why. During this process the Nobel Laureate, Muller, provided incorrect information to the ICRP in what appears to have been an attempt to manipulate the decision-making process and to prevent the dose-rate concept from being adopted into risk assessment practices. - Highlights: • The discovery of radiation dose rate challenged the scientific basis of LNT. • Radiation dose rate occurred in males and females. • The dose rate concept supported a threshold dose-response for radiation.

  14. Ecotoxicology: Lead

    Science.gov (United States)

    Scheuhammer, A.M.; Beyer, W.N.; Schmitt, C.J.; Jorgensen, Sven Erik; Fath, Brian D.

    2008-01-01

    Lead (Pb) is a naturally occurring metallic element; trace concentrations are found in all environmental media and in all living things. However, certain human activities, especially base metal mining and smelting; combustion of leaded gasoline; the use of Pb in hunting, target shooting, and recreational angling; the use of Pb-based paints; and the uncontrolled disposal of Pb-containing products such as old vehicle batteries and electronic devices have resulted in increased environmental levels of Pb, and have created risks for Pb exposure and toxicity in invertebrates, fish, and wildlife in some ecosystems.

  15. Leading men

    DEFF Research Database (Denmark)

    Bekker-Nielsen, Tønnes

    2016-01-01

    Through a systematic comparison of c. 50 careers leading to the koinarchate or high priesthood of Asia, Bithynia, Galatia, Lycia, Macedonia and coastal Pontus, as described in funeral or honorary inscriptions of individual koinarchs, it is possible to identify common denominators but also disting...

  16. Radiation dose effects, hardening of electronic components

    International Nuclear Information System (INIS)

    Dupont-Nivet, E.

    1991-01-01

    This course reviews the mechanism of interaction between ionizing radiation and a silicon oxide type dielectric, in particular the effect of electron-hole pairs creation in the material. Then effects of cumulated dose on electronic components and especially in MOS technology are examined. Finally methods hardening of these components are exposed. 93 refs

  17. Probabilistic assessment of the cumulative dietary acute exposure of the population of Denmark to organophosphorus and carbamate pesticides

    DEFF Research Database (Denmark)

    Jensen, Bodil Hamborg; Petersen, Annette; Christensen, Tue

    2009-01-01

    and methamidophos. RPF values derived from the literature were used in the calculations. We calculated the cumulative acute exposure to 1.8% and 0.8% of the acute reference dose (ARfD) of 100 mu g kg(-1) body weight (bw) day(-1) of chlorpyrifos as an index compound at the 99.9th percentile (P99.5) for children...

  18. Dose escalation by image-guided intensity-modulated radiotherapy leads to an increase in pain relief for spinal metastases: a comparison study with a regimen of 30 Gy in 10 fractions.

    Science.gov (United States)

    He, Jinlan; Xiao, Jianghong; Peng, Xingchen; Duan, Baofeng; Li, Yan; Ai, Ping; Yao, Min; Chen, Nianyong

    2017-12-22

    Under the existing condition that the optimum radiotherapy regimen for spinal metastases is controversial, this study investigates the benefits of dose escalation by image-guided intensity-modulated radiotherapy (IG-IMRT) with 60-66 Gy in 20-30 fractions for spinal metastases. In the dose-escalation group, each D50 of planning gross tumor volume (PGTV) was above 60 Gy and each Dmax of spinal cord planning organ at risk volume (PRV) was below 48 Gy. The median biological effective dose (BED) of Dmax of spinal cord was lower in the dose-escalation group compared with that in the 30-Gy group (69.70 Gy vs. 83.16 Gy, p pain responses were better in the dose-escalation group than those in the 30-Gy group ( p = 0.005 and p = 0.024), and the complete pain relief rates were respectively 73.69% and 34.29% ( p = 0.006), 73.69% and 41.38% ( p = 0.028) in two compared groups. In the dose-escalation group, there is a trend of a longer duration of pain relief, a longer overall survival and a lower incidence of acute radiation toxicities. No late radiation toxicities were observed in both groups. Dosimetric parameters and clinical outcomes, including pain response, duration of pain relief, radiation toxicities and overall survival, were compared among twenty-five metastatic spinal lesions irradiated with the dose-escalation regimen and among forty-four lesions treated with the 30-Gy regimen. Conventionally-fractionated IG-IMRT for spinal metastases could escalate dose to the vertebral lesions while sparing the spinal cord, achieving a better pain relief without increasing radiation complications.

  19. 3D calculation of absorbed dose for 131I-targeted radiotherapy: A Monte Carlo study

    International Nuclear Information System (INIS)

    Saeedzadeh, E.; Sarkar, S.; Abbaspour Tehrani-Fard, A.; Ay, M. R.; Khosravi, H. R.; Loudos, G.

    2008-01-01

    Various methods, such as those developed by the Medical Internal Radiation Dosimetry (MIRD) Committee of the Society of Nuclear Medicine or employing dose point kernels, have been applied to the radiation dosimetry of 131 I radionuclide therapy. However, studies have not shown a strong relationship between tumour absorbed dose and its overall therapeutic response, probably due in part to inaccuracies in activity and dose estimation. In the current study, the GATE Monte Carlo computer code was used to facilitate voxel-level radiation dosimetry for organ activities measured in an. 131 I-treated thyroid cancer patient. This approach allows incorporation of the size, shape and composition of organs (in the current study, in the Zubal anthropomorphic phantom) and intra-organ and intra-tumour inhomogeneities in the activity distributions. The total activities of the tumours and their heterogeneous distributions were measured from the SPECT images to calculate the dose maps. For investigating the effect of activity distribution on dose distribution, a hypothetical homogeneous distribution of the same total activity was considered in the tumours. It was observed that the tumour mean absorbed dose rates per unit cumulated activity were 0.65 E-5 and 0.61 E-5 mGY MBq -1 s -1 for the uniform and non-uniform distributions in the tumour, respectively, which do not differ considerably. However, the dose-volume histograms (DVH) show that the tumour non-uniform activity distribution decreases the absorbed dose to portions of the tumour volume. In such a case, it can be misleading to quote the mean or maximum absorbed dose, because overall response is likely limited by the tumour volume that receives low (i.e. non-cytocidal) doses. Three-dimensional radiation dosimetry, and calculation of tumour DVHs, may lead to the derivation of clinically reliable dose-response relationships and therefore may ultimately improve treatment planning as well as response assessment for radionuclide

  20. Who Leads China's Leading Universities?

    Science.gov (United States)

    Huang, Futao

    2017-01-01

    This study attempts to identify the major characteristics of two different groups of institutional leaders in China's leading universities. The study begins with a review of relevant literature and theory. Then, there is a brief introduction to the selection of party secretaries, deputy secretaries, presidents and vice presidents in leading…

  1. Effects of low doses

    International Nuclear Information System (INIS)

    Le Guen, B.

    2001-01-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  2. The MCRA model for probabilistic single-compound and cumulative risk assessment of pesticides.

    Science.gov (United States)

    van der Voet, Hilko; de Boer, Waldo J; Kruisselbrink, Johannes W; Goedhart, Paul W; van der Heijden, Gerie W A M; Kennedy, Marc C; Boon, Polly E; van Klaveren, Jacob D

    2015-05-01

    Pesticide risk assessment is hampered by worst-case assumptions leading to overly pessimistic assessments. On the other hand, cumulative health effects of similar pesticides are often not taken into account. This paper describes models and a web-based software system developed in the European research project ACROPOLIS. The models are appropriate for both acute and chronic exposure assessments of single compounds and of multiple compounds in cumulative assessment groups. The software system MCRA (Monte Carlo Risk Assessment) is available for stakeholders in pesticide risk assessment at mcra.rivm.nl. We describe the MCRA implementation of the methods as advised in the 2012 EFSA Guidance on probabilistic modelling, as well as more refined methods developed in the ACROPOLIS project. The emphasis is on cumulative assessments. Two approaches, sample-based and compound-based, are contrasted. It is shown that additional data on agricultural use of pesticides may give more realistic risk assessments. Examples are given of model and software validation of acute and chronic assessments, using both simulated data and comparisons against the previous release of MCRA and against the standard software DEEM-FCID used by the Environmental Protection Agency in the USA. It is shown that the EFSA Guidance pessimistic model may not always give an appropriate modelling of exposure. Crown Copyright © 2014. Published by Elsevier Ltd. All rights reserved.

  3. Childhood cumulative risk and obesity: the mediating role of self-regulatory ability.

    Science.gov (United States)

    Evans, Gary W; Fuller-Rowell, Thomas E; Doan, Stacey N

    2012-01-01

    We tested whether early childhood risk exposures are related to weight gain in adolescence and evaluate an underlying mechanism, self-regulatory behavior, for the risk-obesity link. Cumulative risk exposure to 9 sociodemographic (eg, poverty), physical (eg, substandard housing), and psychosocial (eg, family turmoil) stressors was assessed in 244 nine-year-old children. BMI was calculated at age 9 and then 4 years later. At age 9, children's ability to delay gratification as an index of self-regulatory behavior was assessed. Path analyses were then estimated to evaluate our mediational model (Cumulative risk → Self-regulation → BMI) over a 4-year period in a prospective, longitudinal design. Nine-year-old children exposed to a greater accumulation of multiple risk factors show larger gains in adiposity over the next four year period, net of their initial BMI. These gains in BMI during early adolescence are largely accounted for by deteriorated self-regulatory abilities among children facing more cumulative risks. Early childhood risk exposure leads to larger gains in BMI in adolescence. Given the importance of childhood adiposity to the development of obesity later in life, understanding the underlying mechanisms that link early experience to weight gain is an essential task. Deficiencies in self-regulation in response to chronic stress appears to be an important agent in the obesity epidemic.

  4. Cumulative health risk assessment: integrated approaches for multiple contaminants, exposures, and effects

    International Nuclear Information System (INIS)

    Rice, Glenn; Teuschler, Linda; MacDonel, Margaret; Butler, Jim; Finster, Molly; Hertzberg, Rick; Harou, Lynne

    2007-01-01

    Available in abstract form only. Full text of publication follows: As information about environmental contamination has increased in recent years, so has public interest in the combined effects of multiple contaminants. This interest has been highlighted by recent tragedies such as the World Trade Center disaster and hurricane Katrina. In fact, assessing multiple contaminants, exposures, and effects has long been an issue for contaminated sites, including U.S. Department of Energy (DOE) legacy waste sites. Local citizens have explicitly asked the federal government to account for cumulative risks, with contaminants moving offsite via groundwater flow, surface runoff, and air dispersal being a common emphasis. Multiple exposures range from ingestion and inhalation to dermal absorption and external gamma irradiation. Three types of concerns can lead to cumulative assessments: (1) specific sources or releases - e.g., industrial facilities or accidental discharges; (2) contaminant levels - in environmental media or human tissues; and (3) elevated rates of disease - e.g., asthma or cancer. The specific initiator frames the assessment strategy, including a determination of appropriate models to be used. Approaches are being developed to better integrate a variety of data, extending from environmental to internal co-location of contaminants and combined effects, to support more practical assessments of cumulative health risks. (authors)

  5. Cumulative effects of cascade hydropower stations on total dissolved gas supersaturation.

    Science.gov (United States)

    Ma, Qian; Li, Ran; Feng, Jingjie; Lu, Jingying; Zhou, Qin

    2018-03-01

    Elevated levels of total dissolved gas (TDG) may occur downstream of dams during the spill process. These high levels would increase the incidence of gas bubble disease in fish and cause severe environmental impacts. With increasing numbers of cascade hydropower stations being built or planned, the cumulative effects of TDG supersaturation are becoming increasingly prominent. The TDG saturation distribution in the downstream reaches of the Jinsha River was studied to investigate the cumulative effects of TDG supersaturation resulting from the cascade hydropower stations. A comparison of the effects of the joint operation and the single operation of two hydropower stations (XLD and XJB) was performed to analyze the risk degree to fish posed by TDG supersaturation. The results showed that water with supersaturated TDG generated at the upstream cascade can be transported to the downstream power station, leading to cumulative TDG supersaturation effects. Compared with the single operation of XJB, the joint operation of both stations produced a much higher TDG saturation downstream of XJB, especially during the non-flood discharge period. Moreover, the duration of high TDG saturation and the lengths of the lethal and sub-lethal areas were much higher in the joint operation scenario, posing a greater threat to fish and severely damaging the environment. This work provides a scientific basis for strategies to reduce TDG supersaturation to the permissible level and minimize the potential risk of supersaturated TDG.

  6. Race, Space, and Cumulative Disadvantage: A Case Study of the Subprime Lending Collapse.

    Science.gov (United States)

    Rugh, Jacob S; Albright, Len; Massey, Douglas S

    2015-05-01

    In this article, we describe how residential segregation and individual racial disparities generate racialized patterns of subprime lending and lead to financial loss among black borrowers in segregated cities. We conceptualize race as a cumulative disadvantage because of its direct and indirect effects on socioeconomic status at the individual and neighborhood levels, with consequences that reverberate across a borrower's life and between generations. Using Baltimore, Maryland as a case study setting, we combine data from reports filed under the Home Mortgage Disclosure Act with additional loan-level data from mortgage-backed securities. We find that race and neighborhood racial segregation are critical factors explaining black disadvantage across successive stages in the process of lending and foreclosure, controlling for differences in borrower credit scores, income, occupancy status, and loan-to-value ratios. We analyze the cumulative cost of predatory lending to black borrowers in terms of reduced disposable income and lost wealth. We find the cost to be substantial. Black borrowers paid an estimated additional 5 to 11 percent in monthly payments and those that completed foreclosure in the sample lost an excess of $2 million in home equity. These costs were magnified in mostly black neighborhoods and in turn heavily concentrated in communities of color. By elucidating the mechanisms that link black segregation to discrimination we demonstrate how processes of cumulative disadvantage continue to undermine black socioeconomic status in the United States today.

  7. Detection limits by EPR spectroscopy of cumulated doses ionizing radiations in molluscs shells

    International Nuclear Information System (INIS)

    Ostrowski, K.; Burlinska, G.; Dziedzic-Goclawska, A.; Stachowicz, W.; Michalik, J.; Sadlo, J.

    1997-01-01

    The exposure of waters to ionizing radiation from radionuclides stored in concrete containers or freed in nuclear accidents or underwater eruption might be difficult to be proved, when currents, rains, exchange of water displace sand soils or rocks in the bottom. Ionizing radiation evokes stable paramagnetic centers in the crystalline lattice of mineral components in bones as well as in exoskeletons of most molluscs, which are detected by the EPR spectroscopy and could be used as an indicator of the exposure to the action of radiation during prolonged period of time. (authors)

  8. Fitness costs of increased cataract frequency and cumulative radiation dose in natural mammalian populations from Chernobyl

    OpenAIRE

    Lehmann, Philipp; Boraty?ski, Zbyszek; Mappes, Tapio; Mousseau, Timothy A.; M?ller, Anders P.

    2016-01-01

    A cataract is a clouding of the lens that reduces light transmission to the retina, and it decreases the visual acuity of the bearer. The prevalence of cataracts in natural populations of mammals, and their potential ecological significance, is poorly known. Cataracts have been reported to arise from high levels of oxidative stress and a major cause of oxidative stress is ionizing radiation. We investigated whether elevated frequencies of cataracts are found in eyes of bank voles Myodes glare...

  9. Session: What do we know about cumulative or population impacts

    Energy Technology Data Exchange (ETDEWEB)

    Kerlinger, Paul; Manville, Al; Kendall, Bill

    2004-09-01

    This session at the Wind Energy and Birds/Bats workshop consisted of a panel discussion followed by a discussion/question and answer period. The panelists were Paul Kerlinger, Curry and Kerlinger, LLC, Al Manville, U.S. Fish and Wildlife Service, and Bill Kendall, US Geological Service. The panel addressed the potential cumulative impacts of wind turbines on bird and bat populations over time. Panel members gave brief presentations that touched on what is currently known, what laws apply, and the usefulness of population modeling. Topics addressed included which sources of modeling should be included in cumulative impacts, comparison of impacts from different modes of energy generation, as well as what research is still needed regarding cumulative impacts of wind energy development on bird and bat populations.

  10. Estimating a population cumulative incidence under calendar time trends

    DEFF Research Database (Denmark)

    Hansen, Stefan N; Overgaard, Morten; Andersen, Per K

    2017-01-01

    BACKGROUND: The risk of a disease or psychiatric disorder is frequently measured by the age-specific cumulative incidence. Cumulative incidence estimates are often derived in cohort studies with individuals recruited over calendar time and with the end of follow-up governed by a specific date...... by calendar time trends, the total sample Kaplan-Meier and Aalen-Johansen estimators do not provide useful estimates of the general risk in the target population. We present some alternatives to this type of analysis. RESULTS: We show how a proportional hazards model may be used to extrapolate disease risk...... estimates if proportionality is a reasonable assumption. If not reasonable, we instead advocate that a more useful description of the disease risk lies in the age-specific cumulative incidence curves across strata given by time of entry or perhaps just the end of follow-up estimates across all strata...

  11. Evolutionary neural network modeling for software cumulative failure time prediction

    International Nuclear Information System (INIS)

    Tian Liang; Noore, Afzel

    2005-01-01

    An evolutionary neural network modeling approach for software cumulative failure time prediction based on multiple-delayed-input single-output architecture is proposed. Genetic algorithm is used to globally optimize the number of the delayed input neurons and the number of neurons in the hidden layer of the neural network architecture. Modification of Levenberg-Marquardt algorithm with Bayesian regularization is used to improve the ability to predict software cumulative failure time. The performance of our proposed approach has been compared using real-time control and flight dynamic application data sets. Numerical results show that both the goodness-of-fit and the next-step-predictability of our proposed approach have greater accuracy in predicting software cumulative failure time compared to existing approaches

  12. Baltic Sea biodiversity status vs. cumulative human pressures

    DEFF Research Database (Denmark)

    Andersen, Jesper H.; Halpern, Benjamin S.; Korpinen, Samuli

    2015-01-01

    Abstract Many studies have tried to explain spatial and temporal variations in biodiversity status of marine areas from a single-issue perspective, such as fishing pressure or coastal pollution, yet most continental seas experience a wide range of human pressures. Cumulative impact assessments have...... been developed to capture the consequences of multiple stressors for biodiversity, but the ability of these assessments to accurately predict biodiversity status has never been tested or ground-truthed. This relationship has similarly been assumed for the Baltic Sea, especially in areas with impaired...... status, but has also never been documented. Here we provide a first tentative indication that cumulative human impacts relate to ecosystem condition, i.e. biodiversity status, in the Baltic Sea. Thus, cumulative impact assessments offer a promising tool for informed marine spatial planning, designation...

  13. Low doses effects

    International Nuclear Information System (INIS)

    Tubiana, M.

    1997-01-01

    In this article is asked the question about a possible carcinogens effect of low dose irradiation. With epidemiological data, knowledge about the carcinogenesis, the professor Tubiana explains that in spite of experiments made on thousand or hundred of thousands animals it has not been possible to bring to the fore a carcinogens effect for low doses and then it is not reasonable to believe and let the population believe that low dose irradiation could lead to an increase of neoplasms and from this point of view any hardening of radiation protection standards could in fact, increase anguish about ionizing radiations. (N.C.)

  14. Cumulative carbon as a policy framework for achieving climate stabilization

    Science.gov (United States)

    Matthews, H. Damon; Solomon, Susan; Pierrehumbert, Raymond

    2012-01-01

    The primary objective of the United Nations Framework Convention on Climate Change is to stabilize greenhouse gas concentrations at a level that will avoid dangerous climate impacts. However, greenhouse gas concentration stabilization is an awkward framework within which to assess dangerous climate change on account of the significant lag between a given concentration level and the eventual equilibrium temperature change. By contrast, recent research has shown that global temperature change can be well described by a given cumulative carbon emissions budget. Here, we propose that cumulative carbon emissions represent an alternative framework that is applicable both as a tool for climate mitigation as well as for the assessment of potential climate impacts. We show first that both atmospheric CO2 concentration at a given year and the associated temperature change are generally associated with a unique cumulative carbon emissions budget that is largely independent of the emissions scenario. The rate of global temperature change can therefore be related to first order to the rate of increase of cumulative carbon emissions. However, transient warming over the next century will also be strongly affected by emissions of shorter lived forcing agents such as aerosols and methane. Non-CO2 emissions therefore contribute to uncertainty in the cumulative carbon budget associated with near-term temperature targets, and may suggest the need for a mitigation approach that considers separately short- and long-lived gas emissions. By contrast, long-term temperature change remains primarily associated with total cumulative carbon emissions owing to the much longer atmospheric residence time of CO2 relative to other major climate forcing agents. PMID:22869803

  15. The role of factorial cumulants in reactor neutron noise theory

    International Nuclear Information System (INIS)

    Colombino, A.; Pacilio, N.; Sena, G.

    1979-01-01

    The physical meaning and the combinatorial implications of the factorial cumulant of a state variable such as the number of neutrons or the number of neutron counts are specified. Features of the presentation are: (1) the fission process is treated in its entirety without the customary binary emission restriction, (b) the introduction of the factorial cumulants helps in reducing the complexity of the mathematical problems, (c) all the solutions can be obtained analytically. Only the ergodic hypothesis for the neutron population evolution is dealt with. (author)

  16. Super-Resolution Algorithm in Cumulative Virtual Blanking

    Science.gov (United States)

    Montillet, J. P.; Meng, X.; Roberts, G. W.; Woolfson, M. S.

    2008-11-01

    The proliferation of mobile devices and the emergence of wireless location-based services have generated consumer demand for precise location. In this paper, the MUSIC super-resolution algorithm is applied to time delay estimation for positioning purposes in cellular networks. The goal is to position a Mobile Station with UMTS technology. The problem of Base-Stations herability is solved using Cumulative Virtual Blanking. A simple simulator is presented using DS-SS signal. The results show that MUSIC algorithm improves the time delay estimation in both the cases whether or not Cumulative Virtual Blanking was carried out.

  17. Checking Fine and Gray subdistribution hazards model with cumulative sums of residuals

    DEFF Research Database (Denmark)

    Li, Jianing; Scheike, Thomas; Zhang, Mei Jie

    2015-01-01

    Recently, Fine and Gray (J Am Stat Assoc 94:496–509, 1999) proposed a semi-parametric proportional regression model for the subdistribution hazard function which has been used extensively for analyzing competing risks data. However, failure of model adequacy could lead to severe bias in parameter...... estimation, and only a limited contribution has been made to check the model assumptions. In this paper, we present a class of analytical methods and graphical approaches for checking the assumptions of Fine and Gray’s model. The proposed goodness-of-fit test procedures are based on the cumulative sums...

  18. Cumulative Impacts of Energy and Climate Change Policies on Carbon Leakage

    Energy Technology Data Exchange (ETDEWEB)

    Varma, A.; Milnes, R.; Miller, K.; Williams, E. [AEA Technology plc, London (United Kingdom); De Bruyn, S.; Brinke, L. [CE Delft, Delft (Netherlands)

    2012-02-15

    Carbon leakage occurs when climate change policy aimed at reducing carbon dioxide emissions in one country leads to an increase in carbon dioxide emissions in a country that is not bound by these policies. Given that climate change is a global issue, carbon leakage impacts upon the effectiveness of climate change policies. This independent study examines the cumulative impact of climate change policies on carbon leakage. The report brings together findings and analysis from a wide range of primary literature in this area and where possible, conclusions relevant to the UK are drawn.

  19. Entrance surface dose distribution and organ dose assessment for cone-beam computed tomography using measurements and Monte Carlo simulations with voxel phantoms

    Science.gov (United States)

    Baptista, M.; Di Maria, S.; Vieira, S.; Vaz, P.

    2017-11-01

    Cone-Beam Computed Tomography (CBCT) enables high-resolution volumetric scanning of the bone and soft tissue anatomy under investigation at the treatment accelerator. This technique is extensively used in Image Guided Radiation Therapy (IGRT) for pre-treatment verification of patient position and target volume localization. When employed daily and several times per patient, CBCT imaging may lead to high cumulative imaging doses to the healthy tissues surrounding the exposed organs. This work aims at (1) evaluating the dose distribution during a CBCT scan and (2) calculating the organ doses involved in this image guiding procedure for clinically available scanning protocols. Both Monte Carlo (MC) simulations and measurements were performed. To model and simulate the kV imaging system mounted on a linear accelerator (Edge™, Varian Medical Systems) the state-of-the-art MC radiation transport program MCNPX 2.7.0 was used. In order to validate the simulation results, measurements of the Computed Tomography Dose Index (CTDI) were performed, using standard PMMA head and body phantoms, with 150 mm length and a standard pencil ionizing chamber (IC) 100 mm long. Measurements for head and pelvis scanning protocols, usually adopted in clinical environment were acquired, using two acquisition modes (full-fan and half fan). To calculate the organ doses, the implemented MC model of the CBCT scanner together with a male voxel phantom ("Golem") was used. The good agreement between the MCNPX simulations and the CTDIw measurements (differences up to 17%) presented in this work reveals that the CBCT MC model was successfully validated, taking into account the several uncertainties. The adequacy of the computational model to map dose distributions during a CBCT scan is discussed in order to identify ways to reduce the total CBCT imaging dose. The organ dose assessment highlights the need to evaluate the therapeutic and the CBCT imaging doses, in a more balanced approach, and the

  20. Radiation-induced rectal complications are not influenced by age: a dose fractionation study in the rat.

    Science.gov (United States)

    van den Aardweg, Gerard J M J; Olofsen-van Acht, Manouk J J; van Hooije, Christel M C; Levendag, Peter C

    2003-05-01

    Radiation-induced complications of the rectum are an important dose-limiting factor in radiotherapy of pelvic malignancies. In general, animal studies demonstrated no differences in acute and late normal tissue toxicity with age, but little is known about rectal complications in relation to age. For this purpose, an extensive histological and dose fractionation study was carried out on the rectum of young (12 weeks) and older (77-80 weeks) rats. In this paper, the results of dose fractionation are presented in relation to age at the time of irradiation. Young and older animals were irradiated with single and fractionated doses. After irradiation, rectal complications could lead to occlusion and stenosis, eventually resulting in the clinical symptoms of a megacolon and a possible fistula. For each dose group, cumulative survival rates were obtained with Kaplan-Meier analysis, from which dose-effect curves and the associated LD(50) values for a megacolon/fistula were calculated. The majority of responders died between 8 and 24 weeks after irradiation, irrespective of age. For both age groups, only the fractionation data showed a reduction in the mean latency with increasing dose. In the older age group, 39% of the responders developed a fistula compared to 26% for the younger animals. The LD(50) values increased from around 30 Gy after single doses to nearly 65 Gy after 10 fractions. The increases in LD(50) values with the number of fractions were independent of the age of the rats. For each of the dose fractionation schedules, log-rank testing indicated no significant differences in cumulative survival rates between younger and older animals (P > 0.10). The high alpha/beta ratios obtained for both the young and older animals strongly suggested that the late rectal complications were a consequence of early epithelial injury. Associated histological findings indicated that blood vessel damage, which was already evident at a high incidence at 4 weeks after irradiation

  1. Mathematical model for evaluation of dose-rate effect on biological responses to low dose γ-radiation

    International Nuclear Information System (INIS)

    Ogata, H.; Kawakami, Y.; Magae, J.

    2003-01-01

    Full text: To evaluate quantitative dose-response relationship on the biological response to radiation, it is necessary to consider a model including cumulative dose, dose-rate and irradiation time. In this study, we measured micronucleus formation and [ 3 H] thymidine uptake in human cells as indices of biological response to gamma radiation, and analyzed mathematically and statistically the data for quantitative evaluation of radiation risk at low dose/low dose-rate. Effective dose (ED x ) was mathematically estimated by fitting a general function of logistic model to the dose-response relationship. Assuming that biological response depends on not only cumulative dose but also dose-rate and irradiation time, a multiple logistic function was applied to express the relationship of the three variables. Moreover, to estimate the effect of radiation at very low dose, we proposed a modified exponential model. From the results of fitting curves to the inhibition of [ 3 H] thymidine uptake and micronucleus formation, it was obvious that ED 50 in proportion of inhibition of [ 3 H] thymidine uptake increased with longer irradiation time. As for the micronuclei, ED 30 also increased with longer irradiation times. These results suggest that the biological response depends on not only total dose but also irradiation time. The estimated response surface using the three variables showed that the biological response declined sharply when the dose-rate was less than 0.01 Gy/h. These results suggest that the response does not depend on total cumulative dose at very low dose-rates. Further, to investigate the effect of dose-rate within a wider range, we analyzed the relationship between ED x and dose-rate. Fitted curves indicated that ED x increased sharply when dose-rate was less than 10 -2 Gy/h. The increase of ED x signifies the decline of the response or the risk and suggests that the risk approaches to 0 at infinitely low dose-rate

  2. Correlation of cumulative corticosteroid treatment with magnetic resonance imaging assessment of avascular femoral head necrosis in patients with multiple sclerosis

    Directory of Open Access Journals (Sweden)

    Nilufer Kale

    2010-10-01

    Full Text Available Increased risk of osteoporosis, fractures, and avascular necrosis (AVN has been suggested in multiple sclerosis (MS. Patients with MS are often exposed to corticosteroid treatment (CST during the disease course and conflicting reports exist regarding complications of CST. Our study aims to investigate the association between cumulative doses of CST and radiographic evaluation of AVN of the femoral head in MS. Twenty-six MS patients (mean age, 38.4±10 yr were enrolled and prospectively evaluated for AVN by magnetic resonance imaging (MRI. The mean disease duration was 11.5±8.5 years and mean expanded disability status scale (EDSS score was 3±2. The cumulative dosage of CST varied between 20 g and 60 g; patients were grouped into two categories: 1 CST between 20-40 g, 17 (65% patients; 2 CST ≥40 g; 9 (35% patients. The relationship between cumulative CST dosage and MRI diagnosis of AVN was stat­istically insignificant (P>0.9. Clarification of the cumulative effect of CST in the development of AVN is of great importance for future long-term steroid treatment strategies.

  3. [Directions for use of corticosteroids and calcineurin inhibitors against generalized myasthenia gravis: therapeutic strategies that can lead to early improvements and veer away from high-dose oral corticosteroids].

    Science.gov (United States)

    Utsugisawa, Kimiaki; Nagane, Yuriko; Suzuki, Shigeaki; Suzuki, Norihiro

    2012-01-01

    The advent of effective immune treatment has meant that myasthenia gravis (MG) is most often not lethal. However, many MG patients still find it difficult to maintain daily activities due to chronic residual fatigability and long-term side effects of medication, since full remission without immune treatment is not common. Our analysis demonstrated that disease severity, dose of oral corticosteroids, and depressive state are the major independent factors negatively associated with self-reported QOL (MG-QOL15-J score). It is noteworthy that oral corticosteroid, the first-line agent for MG, is negatively associated with patients' QOL. When the analysis took into account MGFA postintervention status and dose of oral prednisolne (PSL), the MG-QOL15-J score of MM status patients taking ≤ 5 mg PSL per day is identically low (i.e., just as good QOL) as that seen in CSR and is a target of treatment. In order to veer away from high-dose oral corticosteroids and to achieve early MM or better status with PSL ≤ 5 mg/day, we advocate the early aggressive treatment strategy that can achieve early improvement by performing an aggressive therapy using combined treatment with plasmapheresis and high-dose intravenous methylprednisolone and then maintain an improved clinical status using low-dose oral corticosteroids and calcineurin inhibitors (cyclosporine microemulsion and tacrolimus). The early stages of MG are susceptible to treatment with calcineurin inhibitors. When using cyclosporine microemulsion for MG, blood concentrations 2 h after administration (C2) correlate with clinical improvement and immediately before administration (C0) with side effects (increased serum creatinine and/or hypertension). Monitoring of C2 and C0 levels is useful to estimate efficacy and safety of the drug.

  4. Cumulative effects of wind turbines. Volume 3: Report on results of consultations on cumulative effects of wind turbines on birds

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    This report gives details of the consultations held in developing the consensus approach taken in assessing the cumulative effects of wind turbines. Contributions on bird issues, and views of stakeholders, the Countryside Council for Wales, electric utilities, Scottish Natural Heritage, and the National Wind Power Association are reported. The scoping of key species groups, where cumulative effects might be expected, consideration of other developments, the significance of any adverse effects, mitigation, regional capacity assessments, and predictive models are discussed. Topics considered at two stakeholder workshops are outlined in the appendices.

  5. Gonad dose in cineurethrocystography

    International Nuclear Information System (INIS)

    Ardran, G.M.; Dixon-Brown, A.; Fursdon, P.S.

    1978-01-01

    The technical factors used for cineurethrocystography for the true lateral projection in females are given. The mid-line radiation dose has been measured with LiF TLD inserted into the vagina in 19 examinations. The average dose recorded was 148 mrad, the range being 50 to 306 mrad, the average number of cine frames exposed was 96. Data obtained using a Rando phantom indicated that the average ovary dose would be 30% greater than the mid-line dose since the near ovary receives a higher dose than the more distant one. The technique used for men is also given, the average gonad dose in six men being 123 mrad, range 56 to 243 mrad when simple lead foil gonad protection was used; the average number of cine frames was 107. The dose in one man without gonad protection was 1575 mrad for 112 cine frames. The results for both sexes compare favourably with those of others reported in the literature and with gonad doses recorded in typical IVP examinations. (author)

  6. Residual, direct and cumulative effect of zinc application on wheat and rice yield under rice-wheat syst

    Directory of Open Access Journals (Sweden)

    R. Khan

    2009-05-01

    Full Text Available Zinc (Zn deficiency is prevalent particularly on calcareous soils of arid and semiarid region. A field experiment was conducted to investigate the direct, residual and cumulative effect of zinc on the yield of wheat and rice in permanent layout for two consecutive years, 2004-05 and 2005-06 at Arid Zone Research Institute D.I. Khan. Soil under study was deficient in Zn (0.8 mg kg-1. Effect of Zn on yield, Zn concentrations in leaf and soils were assessed using wheat variety Naseer-2000 and rice variety IRRI-6. Three rates of Zn, ranging from 0 to 10 kg ha-1 in soil, were applied as zinc sulphate (ZnSO4. 7H2O along with basal dose fertilization of nitrogen, phosphorus and potassium. Mature leaf and soil samples were collected at panicle initiation stage. The results showed that grain yield of wheat and rice was significantly increased by the direct application of 5 and 10 kg Zn ha-1. Highest grain yield of wheat (5467 kg ha-1 was recorded with the direct application of 10 kg Zn ha-1 while 4994 kg ha-1 was recorded with the cumulative application of 10 kg Zn ha-1 but the yield increase due to residual effect of Zn was statistically lower than the cumulative effect of Zn. Maximum paddy yield was recorded with the cumulative application ofZn followed by residual and direct applied 10 and 5 kg Zn kg ha-1, respectively. Zn concentration in soils ranged from 0.3 to 1.5 mg kg-1 in wheat and 0.24 to 2.40 mg kg-1 in rice, while in leaves it ranged from 18-48 mg kg-1 in wheat and 15-52 mg kg-1 in rice. The concentration of Zn in soil and leaves increased due to the treatments in the order; cumulative > residual > direct effect > control (without Zn. The yield attributes like 1000- grain weight, number of spikes, spike length and plant height were increased by the residual, direct and cumulative effect of Zn levels; however, the magnitude of increase was higher in cumulative effect than residual and direct effect of Zn, respectively. Under Zn-deficient soil

  7. Cumulative impacts: current research and current opinions at PSW

    Science.gov (United States)

    R. M. Rice

    1987-01-01

    Consideration of cumulative watershed effects (CWEs) has both political and physical aspects. Regardless of the practical usefulness of present methods of dealing with CWEs, the legal requirement to address them remains. Management of federal land is regulated by the National Environmental Policy Act (NEPA) and the Federal Water Pollution Control Act of 1972. The...

  8. Cumulative Risks of Foster Care Placement for Danish Children

    DEFF Research Database (Denmark)

    Fallesen, Peter; Emanuel, Natalia; Wildeman, Christopher

    2014-01-01

    children. Our results also show some variations by parental ethnicity and sex, but these differences are small. Indeed, they appear quite muted relative to racial/ethnic differences in these risks in the United States. Last, though cumulative risks are similar between Danish and American children...

  9. Disintegration of a profiled shock wave at the cumulation point

    International Nuclear Information System (INIS)

    Kaliski, S.

    1978-01-01

    The disintegration at the cumulation point is analyzed of a shock wave generated with the aid of a profiled pressure. The quantitative relations are analyzed for the disintegration waves for typical compression parameters in systems of thermonuclear microfusion. The quantitative conclusions are drawn for the application of simplifying approximate calculations in problems of microfusion. (author)

  10. Cumulative Prospect Theory, Option Returns, and the Variance Premium

    NARCIS (Netherlands)

    Baele, Lieven; Driessen, Joost; Ebert, Sebastian; Londono Yarce, J.M.; Spalt, Oliver

    The variance premium and the pricing of out-of-the-money (OTM) equity index options are major challenges to standard asset pricing models. We develop a tractable equilibrium model with Cumulative Prospect Theory (CPT) preferences that can overcome both challenges. The key insight is that the

  11. Steps and Pips in the History of the Cumulative Recorder

    Science.gov (United States)

    Lattal, Kennon A.

    2004-01-01

    From its inception in the 1930s until very recent times, the cumulative recorder was the most widely used measurement instrument in the experimental analysis of behavior. It was an essential instrument in the discovery and analysis of schedules of reinforcement, providing the first real-time analysis of operant response rates and patterns. This…

  12. The effects of cumulative practice on mathematics problem solving.

    Science.gov (United States)

    Mayfield, Kristin H; Chase, Philip N

    2002-01-01

    This study compared three different methods of teaching five basic algebra rules to college students. All methods used the same procedures to teach the rules and included four 50-question review sessions interspersed among the training of the individual rules. The differences among methods involved the kinds of practice provided during the four review sessions. Participants who received cumulative practice answered 50 questions covering a mix of the rules learned prior to each review session. Participants who received a simple review answered 50 questions on one previously trained rule. Participants who received extra practice answered 50 extra questions on the rule they had just learned. Tests administered after each review included new questions for applying each rule (application items) and problems that required novel combinations of the rules (problem-solving items). On the final test, the cumulative group outscored the other groups on application and problem-solving items. In addition, the cumulative group solved the problem-solving items significantly faster than the other groups. These results suggest that cumulative practice of component skills is an effective method of training problem solving.

  13. Anti-irritants II: Efficacy against cumulative irritation

    DEFF Research Database (Denmark)

    Andersen, Flemming; Hedegaard, Kathryn; Petersen, Thomas Kongstad

    2006-01-01

    window of opportunity in which to demonstrate efficacy. Therefore, the effect of AI was studied in a cumulative irritation model by inducing irritant dermatitis with 10 min daily exposures for 5+4 days (no irritation on weekend) to 1% sodium lauryl sulfate on the right and 20% nonanoic acid on the left...

  14. Cumulative Beam Breakup with Time-Dependent Parameters

    CERN Document Server

    Delayen, J R

    2004-01-01

    A general analytical formalism developed recently for cumulative beam breakup (BBU) in linear accelerators with arbitrary beam current profile and misalignments [1] is extended to include time-dependent parameters such as energy chirp or rf focusing in order to reduce BBU-induced instabilities and emittance growth. Analytical results are presented and applied to practical accelerator configurations.

  15. On the mechanism of hadron cumulative production on nucleus

    International Nuclear Information System (INIS)

    Efremov, A.V.

    1976-01-01

    A mechanism of cumulative production of hadrons on nucleus is proposed which is similar to that of high perpendicular hadron production. The cross section obtained describes the main qualitative features of such prosesses, e.g., initial energy dependence atomic number behaviour, dependence on the rest mass of the produced particle and its production angle

  16. Hyperscaling breakdown and Ising spin glasses: The Binder cumulant

    Science.gov (United States)

    Lundow, P. H.; Campbell, I. A.

    2018-02-01

    Among the Renormalization Group Theory scaling rules relating critical exponents, there are hyperscaling rules involving the dimension of the system. It is well known that in Ising models hyperscaling breaks down above the upper critical dimension. It was shown by Schwartz (1991) that the standard Josephson hyperscaling rule can also break down in Ising systems with quenched random interactions. A related Renormalization Group Theory hyperscaling rule links the critical exponents for the normalized Binder cumulant and the correlation length in the thermodynamic limit. An appropriate scaling approach for analyzing measurements from criticality to infinite temperature is first outlined. Numerical data on the scaling of the normalized correlation length and the normalized Binder cumulant are shown for the canonical Ising ferromagnet model in dimension three where hyperscaling holds, for the Ising ferromagnet in dimension five (so above the upper critical dimension) where hyperscaling breaks down, and then for Ising spin glass models in dimension three where the quenched interactions are random. For the Ising spin glasses there is a breakdown of the normalized Binder cumulant hyperscaling relation in the thermodynamic limit regime, with a return to size independent Binder cumulant values in the finite-size scaling regime around the critical region.

  17. How to manage the cumulative flood safety of catchment dams ...

    African Journals Online (AJOL)

    Dam safety is a significant issue being taken seriously worldwide. However, in Australia, although much attention is being devoted to the medium- to large-scale dams, minimal attention is being paid to the serious potential problems associated with smaller dams, particularly the potential cumulative safety threats they pose ...

  18. Cumulative Beam Breakup due to Resistive-Wall Wake

    International Nuclear Information System (INIS)

    Wang, J.-M.

    2004-01-01

    The cumulative beam breakup problem excited by the resistive-wall wake is formulated. An approximate analytic method of finding the asymptotic behavior for the transverse bunch displacement is developed and solved. Comparison between the asymptotic analytical expression and the direct numerical solution is presented. Good agreement is found. The criterion of using the asymptotic analytical expression is discussed

  19. Analysis of sensory ratings data with cumulative link models

    DEFF Research Database (Denmark)

    Christensen, Rune Haubo Bojesen; Brockhoff, Per B.

    2013-01-01

    Examples of categorical rating scales include discrete preference, liking and hedonic rating scales. Data obtained on these scales are often analyzed with normal linear regression methods or with omnibus Pearson chi2 tests. In this paper we propose to use cumulative link models that allow for reg...

  20. Implications of applying cumulative risk assessment to the workplace.

    Science.gov (United States)

    Fox, Mary A; Spicer, Kristen; Chosewood, L Casey; Susi, Pam; Johns, Douglas O; Dotson, G Scott

    2018-06-01

    Multiple changes are influencing work, workplaces and workers in the US including shifts in the main types of work and the rise of the 'gig' economy. Work and workplace changes have coincided with a decline in unions and associated advocacy for improved safety and health conditions. Risk assessment has been the primary method to inform occupational and environmental health policy and management for many types of hazards. Although often focused on one hazard at a time, risk assessment frameworks and methods have advanced toward cumulative risk assessment recognizing that exposure to a single chemical or non-chemical stressor rarely occurs in isolation. We explore how applying cumulative risk approaches may change the roles of workers and employers as they pursue improved health and safety and elucidate some of the challenges and opportunities that might arise. Application of cumulative risk assessment should result in better understanding of complex exposures and health risks with the potential to inform more effective controls and improved safety and health risk management overall. Roles and responsibilities of both employers and workers are anticipated to change with potential for a greater burden of responsibility on workers to address risk factors both inside and outside the workplace that affect health at work. A range of policies, guidance and training have helped develop cumulative risk assessment for the environmental health field and similar approaches are available to foster the practice in occupational safety and health. Copyright © 2018 Elsevier Ltd. All rights reserved.

  1. Hierarchical Bayesian parameter estimation for cumulative prospect theory

    NARCIS (Netherlands)

    Nilsson, H.; Rieskamp, J.; Wagenmakers, E.-J.

    2011-01-01

    Cumulative prospect theory (CPT Tversky & Kahneman, 1992) has provided one of the most influential accounts of how people make decisions under risk. CPT is a formal model with parameters that quantify psychological processes such as loss aversion, subjective values of gains and losses, and

  2. An Axiomatization of Cumulative Prospect Theory for Decision under Risk

    NARCIS (Netherlands)

    Wakker, P.P.; Chateauneuf, A.

    1999-01-01

    Cumulative prospect theory was introduced by Tversky and Kahneman so as to combine the empirical realism of their original prospect theory with the theoretical advantages of Quiggin's rank-dependent utility. Preference axiomatizations were provided in several papers. All those axiomatizations,

  3. Cumulative assessment: does it improve students’ knowledge acquisition and retention?

    NARCIS (Netherlands)

    Cecilio Fernandes, Dario; Nagtegaal, Manouk; Noordzij, Gera; Tio, Rene

    2017-01-01

    Introduction Assessment for learning means changing students’ behaviour regarding their learning. Cumulative assessment has been shown to increase students’ self-study time and spread their study time throughout a course. However, there was no difference regarding students’ knowledge at the end of

  4. Effective dose and dose to crystalline lens during angiographic procedures

    International Nuclear Information System (INIS)

    Pages, J.

    1998-01-01

    The highest radiation doses levels received by radiologists are observed during interventional procedures. Doses to forehead and neck received by a radiologist executing angiographic examinations at the department of radiology at the academic hospital (AZ-VUB) have been measured for a group of 34 examinations. The doses to crystalline lens and the effective doses for a period of one year have been estimated. For the crystalline lens the maximum dose approaches the ICRP limit, that indicates the necessity for the radiologist to use leaded glasses. (N.C.)

  5. The challenges and opportunities in cumulative effects assessment

    Energy Technology Data Exchange (ETDEWEB)

    Foley, Melissa M., E-mail: mfoley@usgs.gov [U.S. Geological Survey, Pacific Coastal and Marine Science Center, 400 Natural Bridges, Dr., Santa Cruz, CA 95060 (United States); Center for Ocean Solutions, Stanford University, 99 Pacific St., Monterey, CA 93940 (United States); Mease, Lindley A., E-mail: lamease@stanford.edu [Center for Ocean Solutions, Stanford University, 473 Via Ortega, Stanford, CA 94305 (United States); Martone, Rebecca G., E-mail: rmartone@stanford.edu [Center for Ocean Solutions, Stanford University, 99 Pacific St., Monterey, CA 93940 (United States); Prahler, Erin E. [Center for Ocean Solutions, Stanford University, 473 Via Ortega, Stanford, CA 94305 (United States); Morrison, Tiffany H., E-mail: tiffany.morrison@jcu.edu.au [ARC Centre of Excellence for Coral Reef Studies, James Cook University, Townsville, QLD, 4811 (Australia); Murray, Cathryn Clarke, E-mail: cmurray@pices.int [WWF-Canada, 409 Granville Street, Suite 1588, Vancouver, BC V6C 1T2 (Canada); Wojcik, Deborah, E-mail: deb.wojcik@duke.edu [Nicholas School for the Environment, Duke University, 9 Circuit Dr., Durham, NC 27708 (United States)

    2017-01-15

    The cumulative effects of increasing human use of the ocean and coastal zone have contributed to a rapid decline in ocean and coastal resources. As a result, scientists are investigating how multiple, overlapping stressors accumulate in the environment and impact ecosystems. These investigations are the foundation for the development of new tools that account for and predict cumulative effects in order to more adequately prevent or mitigate negative effects. Despite scientific advances, legal requirements, and management guidance, those who conduct assessments—including resource managers, agency staff, and consultants—continue to struggle to thoroughly evaluate cumulative effects, particularly as part of the environmental assessment process. Even though 45 years have passed since the United States National Environmental Policy Act was enacted, which set a precedent for environmental assessment around the world, defining impacts, baseline, scale, and significance are still major challenges associated with assessing cumulative effects. In addition, we know little about how practitioners tackle these challenges or how assessment aligns with current scientific recommendations. To shed more light on these challenges and gaps, we undertook a comparative study on how cumulative effects assessment (CEA) is conducted by practitioners operating under some of the most well-developed environmental laws around the globe: California, USA; British Columbia, Canada; Queensland, Australia; and New Zealand. We found that practitioners used a broad and varied definition of impact for CEA, which led to differences in how baseline, scale, and significance were determined. We also found that practice and science are not closely aligned and, as such, we highlight opportunities for managers, policy makers, practitioners, and scientists to improve environmental assessment.

  6. The challenges and opportunities in cumulative effects assessment

    International Nuclear Information System (INIS)

    Foley, Melissa M.; Mease, Lindley A.; Martone, Rebecca G.; Prahler, Erin E.; Morrison, Tiffany H.; Murray, Cathryn Clarke; Wojcik, Deborah

    2017-01-01

    The cumulative effects of increasing human use of the ocean and coastal zone have contributed to a rapid decline in ocean and coastal resources. As a result, scientists are investigating how multiple, overlapping stressors accumulate in the environment and impact ecosystems. These investigations are the foundation for the development of new tools that account for and predict cumulative effects in order to more adequately prevent or mitigate negative effects. Despite scientific advances, legal requirements, and management guidance, those who conduct assessments—including resource managers, agency staff, and consultants—continue to struggle to thoroughly evaluate cumulative effects, particularly as part of the environmental assessment process. Even though 45 years have passed since the United States National Environmental Policy Act was enacted, which set a precedent for environmental assessment around the world, defining impacts, baseline, scale, and significance are still major challenges associated with assessing cumulative effects. In addition, we know little about how practitioners tackle these challenges or how assessment aligns with current scientific recommendations. To shed more light on these challenges and gaps, we undertook a comparative study on how cumulative effects assessment (CEA) is conducted by practitioners operating under some of the most well-developed environmental laws around the globe: California, USA; British Columbia, Canada; Queensland, Australia; and New Zealand. We found that practitioners used a broad and varied definition of impact for CEA, which led to differences in how baseline, scale, and significance were determined. We also found that practice and science are not closely aligned and, as such, we highlight opportunities for managers, policy makers, practitioners, and scientists to improve environmental assessment.

  7. The challenges and opportunities in cumulative effects assessment

    Science.gov (United States)

    Foley, Melissa M.; Mease, Lindley A; Martone, Rebecca G; Prahler, Erin E; Morrison, Tiffany H; Clarke Murray, Cathryn; Wojcik, Deborah

    2016-01-01

    The cumulative effects of increasing human use of the ocean and coastal zone have contributed to a rapid decline in ocean and coastal resources. As a result, scientists are investigating how multiple, overlapping stressors accumulate in the environment and impact ecosystems. These investigations are the foundation for the development of new tools that account for and predict cumulative effects in order to more adequately prevent or mitigate negative effects. Despite scientific advances, legal requirements, and management guidance, those who conduct assessments—including resource managers, agency staff, and consultants—continue to struggle to thoroughly evaluate cumulative effects, particularly as part of the environmental assessment process. Even though 45 years have passed since the United States National Environmental Policy Act was enacted, which set a precedent for environmental assessment around the world, defining impacts, baseline, scale, and significance are still major challenges associated with assessing cumulative effects. In addition, we know little about how practitioners tackle these challenges or how assessment aligns with current scientific recommendations. To shed more light on these challenges and gaps, we undertook a comparative study on how cumulative effects assessment (CEA) is conducted by practitioners operating under some of the most well-developed environmental laws around the globe: California, USA; British Columbia, Canada; Queensland, Australia; and New Zealand. We found that practitioners used a broad and varied definition of impact for CEA, which led to differences in how baseline, scale, and significance were determined. We also found that practice and science are not closely aligned and, as such, we highlight opportunities for managers, policy makers, practitioners, and scientists to improve environmental assessment.

  8. The role of cumulative physical work load in symptomatic knee osteoarthritis – a case-control study in Germany

    Directory of Open Access Journals (Sweden)

    Abolmaali Nasreddin

    2008-07-01

    Full Text Available Abstract Objectives To examine the dose-response relationship between cumulative exposure to kneeling and squatting as well as to lifting and carrying of loads and symptomatic knee osteoarthritis (OA in a population-based case-control study. Methods In five orthopedic clinics and five practices we recruited 295 male patients aged 25 to 70 with radiographically confirmed knee osteoarthritis associated with chronic complaints. A total of 327 male control subjects were recruited. Data were gathered in a structured personal interview. To calculate cumulative exposure, the self-reported duration of kneeling and squatting as well as the duration of lifting and carrying of loads were summed up over the entire working life. Results The results of our study support a dose-response relationship between kneeling/squatting and symptomatic knee osteoarthritis. For a cumulative exposure to kneeling and squatting > 10.800 hours, the risk of having radiographically confirmed knee osteoarthritis as measured by the odds ratio (adjusted for age, region, weight, jogging/athletics, and lifting or carrying of loads is 2.4 (95% CI 1.1–5.0 compared to unexposed subjects. Lifting and carrying of loads is significantly associated with knee osteoarthritis independent of kneeling or similar activities. Conclusion As the knee osteoarthritis risk is strongly elevated in occupations that involve both kneeling/squatting and heavy lifting/carrying, preventive efforts should particularly focus on these "high-risk occupations".

  9. Assessment of dose using TLD during activity handling at RPhL, BRIT

    International Nuclear Information System (INIS)

    Choughule, Nitin V.; Bairwa, S.M.; Murali, S.; Rakesh, R.B.; Madhumita, B.; Adtani, M.M.; Mehra, Kiran; Padmanabhan, D.; Borkute, S.D.; Pal, N.; Sachdev, S.S.

    2012-01-01

    Radiopharmaceutical Lab (RPhL), BRIT undertakes production, supply of radiopharmaceuticals. At RPhL short lived isotopes 131 I, 99 Mo, 99m Tc, 125 I, 153 Sm, 32 P and 51 Cr, are handled with total activity handled per week ranging from MBq to TBq (mCiCi). Radiological survey provides idea on radiation level helps to ensure safe working condition. In order to improve the working condition and to estimate the integrated dose over a period of week with uniform pattern of activity handling in the period, a study was carried out using TLD badges. Specifically prepared TLD badges containing CaSO 4 :Dy phosphor were placed at various locations at RPhL It is used for personnel monitoring. One set of TLD was exposed for a week long period while the other set was exposed only during activity handling, kept in the lead pot during the rest of the period. Dose measured by TLDs were compared with the dose estimated using the survey data for the respective locations as well as with the dose estimated using the activity handled by taking into account the time, distance and shielding. The maximum radiation level recorded during lab survey was used to estimate the TLD exposure during the period. It was observed that results on TLD dose measurement and estimated doses using survey results were of same order. The cumulative TLD dose recorded for week duration (168 h) was significantly higher than doses recorded by exposed TLD only during activity handling (8 h). It was expected that the TLD dose would not be more than dose estimated using radiation survey data, while in 3 among 8 experimental TLDs, the dose was ∼ 25% higher. This could be due to the movement of active material or open handling of activity do not get reflected during normal radiation survey and contribution from background radiation at the lab where those TLDs were placed. The individual dose of all the personnel working in different labs were well within the relevant dose limits indicating the safe working condition

  10. Dose limits

    International Nuclear Information System (INIS)

    Fitoussi, L.

    1987-12-01

    The dose limit is defined to be the level of harmfulness which must not be exceeded, so that an activity can be exercised in a regular manner without running a risk unacceptable to man and the society. The paper examines the effects of radiation categorised into stochastic and non-stochastic. Dose limits for workers and the public are discussed

  11. Measurement of four-particle cumulants and symmetric cumulants with subevent methods in small collision systems with the ATLAS detector

    CERN Document Server

    Derendarz, Dominik; The ATLAS collaboration

    2018-01-01

    Measurements of symmetric cumulants SC(n,m)=⟨v2nv2m⟩−⟨v2n⟩⟨v2m⟩ for (n,m)=(2,3) and (2,4) and asymmetric cumulant AC(n) are presented in pp, p+Pb and peripheral Pb+Pb collisions at various collision energies, aiming to probe the long-range collective nature of multi-particle production in small systems. Results are obtained using the standard cumulant method, as well as the two-subevent and three-subevent cumulant methods. Results from the standard method are found to be strongly biased by non-flow correlations as indicated by strong sensitivity to the chosen event class definition. A systematic reduction of non-flow effects is observed when using the two-subevent method and the results become independent of event class definition when the three-subevent method is used. The measured SC(n,m) shows an anti-correlation between v2 and v3, and a positive correlation between v2 and v4. The magnitude of SC(n,m) is constant with Nch in pp collisions, but increases with Nch in p+Pb and Pb+Pb collisions. ...

  12. Gamma irradiator dose mapping simulation using the MCNP code and benchmarking with dosimetry

    International Nuclear Information System (INIS)

    Sohrabpour, M.; Hassanzadeh, M.; Shahriari, M.; Sharifzadeh, M.

    2002-01-01

    The Monte Carlo transport code, MCNP, has been applied in simulating dose rate distribution in the IR-136 gamma irradiator system. Isodose curves, cumulative dose values, and system design data such as throughputs, over-dose-ratios, and efficiencies have been simulated as functions of product density. Simulated isodose curves, and cumulative dose values were compared with dosimetry values obtained using polymethyle-methacrylate, Fricke, ethanol-chlorobenzene, and potassium dichromate dosimeters. The produced system design data were also found to agree quite favorably with those of the system manufacturer's data. MCNP has thus been found to be an effective transport code for handling of various dose mapping excercises for gamma irradiators

  13. Radiation dose electrophysiology procedures

    International Nuclear Information System (INIS)

    Hernandez-Armas, J.; Rodriguez, A.; Catalan, A.; Hernandez Armas, O.; Luque Japon, L.; Moral, S.; Barroso, L.; Rfuez-Hdez, R.

    2006-01-01

    The aim of this paper has been to measure and analyse some of the parameters which are directly related with the doses given to patients in two electrophysiology procedures: diagnosis and ablation with radiofrequency. 16 patients were considered in this study. 13 them had an ablation with radiofrequency at the Unit of Electrophysiology at the University Hospital of the Canaries, La Laguna., Tenerife. The results of skin doses, in the ablation cases, were higher than 2 Gy (threshold of some deterministic effects). The average value was 1.1 Gy. The personal doses, measured under the lead apron, for physician and nurses were 4 and 3 micro Sievert. These results emphasised the necessity of radiation protection measures in order to reduce, ad much as possible, the doses to patients. (Author)

  14. Radiation Dose Risk and Diagnostic Benefit in Imaging Investigations

    OpenAIRE

    Dobrescu, Lidia; Rădulescu, Gheorghe-Cristian

    2015-01-01

    The paper presents many facets of medical imaging investigations radiological risks. The total volume of prescribed medical investigations proves a serious lack in monitoring and tracking of the cumulative radiation doses in many health services. Modern radiological investigations equipment is continuously reducing the total dose of radiation due to improved technologies, so a decrease in per caput dose can be noticed, but the increasing number of investigations has determined a net increase ...

  15. End-stage renal disease after occupational lead exposure: 20 years of follow-up.

    Science.gov (United States)

    Evans, Marie; Discacciati, Andrea; Quershi, Abdul Rashid; Åkesson, Agneta; Elinder, Carl-Gustaf

    2017-06-01

    Whether low-level exposure to lead may give rise to chronic kidney disease or end-stage renal disease (ESRD) is debated. In this study, we aimed to specifically investigate if low-level occupational exposure to lead was associated with increased incidence of ESRD. The incidence of starting renal replacement therapy as a result of ESRD was examined in a cohort of10 303 lead-workers who had controlled blood lead concentrations due to a compulsory occupational health surveillance programme in Sweden during the time period 1977-1990. The ESRD incidence (obtained through register-linkage) among the lead-exposed workers was compared with the age, sex and calendar period-adjusted expected incidence based on data from the Swedish renal registry. Dose-response association was evaluated in external (general population) and internal (within the occupational cohort) comparisons by highest achieved blood lead level. There were 30 (0.29%) individuals in the cohort who developed ESRD during the median follow-up period of 26.3 years. The standardised incidence ratio (SIR) for ESRD incidence was 0.79 (95% CI 0.54 to 1.13). Among those who achieved the highest blood lead (>41.4 µg/dL), the SIR was 1.01 (0.44 to 1.99). There was no evidence of a dose-response relationship between the maximum achieved blood lead or the cumulative blood lead exposure and ESRD in external or internal comparisons. This study of workers with documented occupational lead exposures followed for 20 years shows no statistically significant association between lead exposure (following the current occupational recommendations for Sweden) and ESRD. Published by the BMJ Publishing Group Limited. For permission to use (where not already granted under a licence) please go to http://www.bmj.com/company/products-services/rights-and-licensing/.

  16. An investigation of the alternating fractionation formula of the Cumulative Radiation Effect

    International Nuclear Information System (INIS)

    Hamlet, R.; Kirk, J.; Perry, A.M.

    1980-01-01

    The alternating fractionation formula of the Cumulative Radiation Effect (CRE) system was investigated using the mouse intestinal crypt system as a method of assessment of the amount of radiation damage in a normal tissue. The experimental results revealed that the formula is correct in predicting an increased effect with alternating large and small sized fractions, when compared with a standard schedule where the fraction size was kept constant but achieved the same total dose. However, the results also demonstrated that the order in which the alternate fractions were administered affected the amount of radiation damage produced in the tissue. This observation is in contradiction to another prediction of the formula, that the order in which equal numbers of fractions of different magnitudes are administered, will have no effect on the biological end point. The formula, therefore, is only an approximate model of radiation damage in normal tissue and much more information is required before it can be improved upon. (author)

  17. Non-Chemical Stressors and Cumulative Risk Assessment: An Overview of Current Initiatives and Potential Air Pollutant Interactions

    Science.gov (United States)

    Lewis, Ari S.; Sax, Sonja N.; Wason, Susan C.; Campleman, Sharan L.

    2011-01-01

    Regulatory agencies are under increased pressure to consider broader public health concerns that extend to multiple pollutant exposures, multiple exposure pathways, and vulnerable populations. Specifically, cumulative risk assessment initiatives have stressed the importance of considering both chemical and non-chemical stressors, such as socioeconomic status (SES) and related psychosocial stress, in evaluating health risks. The integration of non-chemical stressors into a cumulative risk assessment framework has been largely driven by evidence of health disparities across different segments of society that may also bear a disproportionate risk from chemical exposures. This review will discuss current efforts to advance the field of cumulative risk assessment, highlighting some of the major challenges, discussed within the construct of the traditional risk assessment paradigm. Additionally, we present a summary of studies of potential interactions between social stressors and air pollutants on health as an example of current research that supports the incorporation of non-chemical stressors into risk assessment. The results from these studies, while suggestive of possible interactions, are mixed and hindered by inconsistent application of social stress indicators. Overall, while there have been significant advances, further developments across all of the risk assessment stages (i.e., hazard identification, exposure assessment, dose-response, and risk characterization) are necessary to provide a scientific basis for regulatory actions and effective community interventions, particularly when considering non-chemical stressors. A better understanding of the biological underpinnings of social stress on disease and implications for chemical-based dose-response relationships is needed. Furthermore, when considering non-chemical stressors, an appropriate metric, or series of metrics, for risk characterization is also needed. Cumulative risk assessment research will benefit

  18. Cumulants of heat transfer across nonlinear quantum systems

    Science.gov (United States)

    Li, Huanan; Agarwalla, Bijay Kumar; Li, Baowen; Wang, Jian-Sheng

    2013-12-01

    We consider thermal conduction across a general nonlinear phononic junction. Based on two-time observation protocol and the nonequilibrium Green's function method, heat transfer in steady-state regimes is studied, and practical formulas for the calculation of the cumulant generating function are obtained. As an application, the general formalism is used to study anharmonic effects on fluctuation of steady-state heat transfer across a single-site junction with a quartic nonlinear on-site pinning potential. An explicit nonlinear modification to the cumulant generating function exact up to the first order is given, in which the Gallavotti-Cohen fluctuation symmetry is found still valid. Numerically a self-consistent procedure is introduced, which works well for strong nonlinearity.

  19. A cumulant functional for static and dynamic correlation

    International Nuclear Information System (INIS)

    Hollett, Joshua W.; Hosseini, Hessam; Menzies, Cameron

    2016-01-01

    A functional for the cumulant energy is introduced. The functional is composed of a pair-correction and static and dynamic correlation energy components. The pair-correction and static correlation energies are functionals of the natural orbitals and the occupancy transferred between near-degenerate orbital pairs, rather than the orbital occupancies themselves. The dynamic correlation energy is a functional of the statically correlated on-top two-electron density. The on-top density functional used in this study is the well-known Colle-Salvetti functional. Using the cc-pVTZ basis set, the functional effectively models the bond dissociation of H 2 , LiH, and N 2 with equilibrium bond lengths and dissociation energies comparable to those provided by multireference second-order perturbation theory. The performance of the cumulant functional is less impressive for HF and F 2 , mainly due to an underestimation of the dynamic correlation energy by the Colle-Salvetti functional.

  20. Fragmentation of tensor polarized deuterons into cumulative pions

    International Nuclear Information System (INIS)

    Afanas'ev, S.; Arkhipov, V.; Bondarev, V.

    1998-01-01

    The tensor analyzing power T 20 of the reaction d polarized + A → π - (0 0 ) + X has been measured in the fragmentation of 9 GeV tensor polarized deuterons into pions with momenta from 3.5 to 5.3 GeV/c on hydrogen, beryllium and carbon targets. This kinematic range corresponds to the region of cumulative hadron production with the cumulative variable x c from 1.08 to 1.76. The values of T 20 have been found to be small and consistent with positive values. This contradicts the predictions based on a direct mechanism assuming NN collision between a high momentum nucleon in the deuteron and a target nucleon (NN → NNπ)

  1. Ecosystem assessment methods for cumulative effects at the regional scale

    International Nuclear Information System (INIS)

    Hunsaker, C.T.

    1989-01-01

    Environmental issues such as nonpoint-source pollution, acid rain, reduced biodiversity, land use change, and climate change have widespread ecological impacts and require an integrated assessment approach. Since 1978, the implementing regulations for the National Environmental Policy Act (NEPA) have required assessment of potential cumulative environmental impacts. Current environmental issues have encouraged ecologists to improve their understanding of ecosystem process and function at several spatial scales. However, management activities usually occur at the local scale, and there is little consideration of the potential impacts to the environmental quality of a region. This paper proposes that regional ecological risk assessment provides a useful approach for assisting scientists in accomplishing the task of assessing cumulative impacts. Critical issues such as spatial heterogeneity, boundary definition, and data aggregation are discussed. Examples from an assessment of acidic deposition effects on fish in Adirondack lakes illustrate the importance of integrated data bases, associated modeling efforts, and boundary definition at the regional scale

  2. Cumulative toxicity of neonicotinoid insecticide mixtures to Chironomus dilutus under acute exposure scenarios.

    Science.gov (United States)

    Maloney, Erin M; Morrissey, Christy A; Headley, John V; Peru, Kerry M; Liber, Karsten

    2017-11-01

    Extensive agricultural use of neonicotinoid insecticide products has resulted in the presence of neonicotinoid mixtures in surface waters worldwide. Although many aquatic insect species are known to be sensitive to neonicotinoids, the impact of neonicotinoid mixtures is poorly understood. In the present study, the cumulative toxicities of binary and ternary mixtures of select neonicotinoids (imidacloprid, clothianidin, and thiamethoxam) were characterized under acute (96-h) exposure scenarios using the larval midge Chironomus dilutus as a representative aquatic insect species. Using the MIXTOX approach, predictive parametric models were fitted and statistically compared with observed toxicity in subsequent mixture tests. Single-compound toxicity tests yielded median lethal concentration (LC50) values of 4.63, 5.93, and 55.34 μg/L for imidacloprid, clothianidin, and thiamethoxam, respectively. Because of the similar modes of action of neonicotinoids, concentration-additive cumulative mixture toxicity was the predicted model. However, we found that imidacloprid-clothianidin mixtures demonstrated response-additive dose-level-dependent synergism, clothianidin-thiamethoxam mixtures demonstrated concentration-additive synergism, and imidacloprid-thiamethoxam mixtures demonstrated response-additive dose-ratio-dependent synergism, with toxicity shifting from antagonism to synergism as the relative concentration of thiamethoxam increased. Imidacloprid-clothianidin-thiamethoxam ternary mixtures demonstrated response-additive synergism. These results indicate that, under acute exposure scenarios, the toxicity of neonicotinoid mixtures to C. dilutus cannot be predicted using the common assumption of additive joint activity. Indeed, the overarching trend of synergistic deviation emphasizes the need for further research into the ecotoxicological effects of neonicotinoid insecticide mixtures in field settings, the development of better toxicity models for neonicotinoid mixture

  3. Polarization in high Psub(trans) and cumulative hadron production

    International Nuclear Information System (INIS)

    Efremov, A.V.

    1978-01-01

    The final hadron polarization in the high Psub(trans) processes is analyzed in the parton hard scattering picture. Scaling assumption allows a correct qualitative description to be given for the Psub(trans)-behaviour of polarization or escape angle behaviour in cumulative production. The energy scaling and weak dependence on the beam and target type is predicted. A method is proposed for measuring the polarization of hadron jets

  4. Seasonal climate change patterns due to cumulative CO2 emissions

    Science.gov (United States)

    Partanen, Antti-Ilari; Leduc, Martin; Damon Matthews, H.

    2017-07-01

    Cumulative CO2 emissions are near linearly related to both global and regional changes in annual-mean surface temperature. These relationships are known as the transient climate response to cumulative CO2 emissions (TCRE) and the regional TCRE (RTCRE), and have been shown to remain approximately constant over a wide range of cumulative emissions. Here, we assessed how well this relationship holds for seasonal patterns of temperature change, as well as for annual-mean and seasonal precipitation patterns. We analyzed an idealized scenario with CO2 concentration growing at an annual rate of 1% using data from 12 Earth system models from the Coupled Model Intercomparison Project Phase 5 (CMIP5). Seasonal RTCRE values for temperature varied considerably, with the highest seasonal variation evident in the Arctic, where RTCRE was about 5.5 °C per Tt C for boreal winter and about 2.0 °C per Tt C for boreal summer. Also the precipitation response in the Arctic during boreal winter was stronger than during other seasons. We found that emission-normalized seasonal patterns of temperature change were relatively robust with respect to time, though they were sub-linear with respect to emissions particularly near the Arctic. Moreover, RTCRE patterns for precipitation could not be quantified robustly due to the large internal variability of precipitation. Our results suggest that cumulative CO2 emissions are a useful metric to predict regional and seasonal changes in precipitation and temperature. This extension of the TCRE framework to seasonal and regional climate change is helpful for communicating the link between emissions and climate change to policy-makers and the general public, and is well-suited for impact studies that could make use of estimated regional-scale climate changes that are consistent with the carbon budgets associated with global temperature targets.

  5. Cumulant approach to dynamical correlation functions at finite temperatures

    International Nuclear Information System (INIS)

    Tran Minhtien.

    1993-11-01

    A new theoretical approach, based on the introduction of cumulants, to calculate thermodynamic averages and dynamical correlation functions at finite temperatures is developed. The method is formulated in Liouville instead of Hilbert space and can be applied to operators which do not require to satisfy fermion or boson commutation relations. The application of the partitioning and projection methods for the dynamical correlation functions is discussed. The present method can be applied to weakly as well as to strongly correlated systems. (author). 9 refs

  6. Severe occupational hand eczema, job stress and cumulative sickness absence.

    Science.gov (United States)

    Böhm, D; Stock Gissendanner, S; Finkeldey, F; John, S M; Werfel, T; Diepgen, T L; Breuer, K

    2014-10-01

    Stress is known to activate or exacerbate dermatoses, but the relationships between chronic stress, job-related stress and sickness absence among occupational hand eczema (OHE) patients are inadequately understood. To see whether chronic stress or burnout symptoms were associated with cumulative sickness absence in patients with OHE and to determine which factors predicted sickness absence in a model including measures of job-related and chronic stress. We investigated correlations of these factors in employed adult inpatients with a history of sickness absence due to OHE in a retrospective cross-sectional explorative study, which assessed chronic stress (Trier Inventory for the Assessment of Chronic Stress), burnout (Shirom Melamed Burnout Measure), clinical symptom severity (Osnabrück Hand Eczema Severity Index), perceived symptom severity, demographic characteristics and cumulative days of sickness absence. The study group consisted of 122 patients. OHE symptoms were not more severe among patients experiencing greater stress and burnout. Women reported higher levels of chronic stress on some measures. Cumulative days of sickness absence correlated with individual dimensions of job-related stress and, in multiple regression analysis, with an overall measure of chronic stress. Chronic stress is an additional factor predicting cumulative sickness absence among severely affected OHE patients. Other relevant factors for this study sample included the 'cognitive weariness' subscale of the Shirom Melamed Burnout Measure and the physical component summary score of the SF-36, a measure of health-related life quality. Prevention and rehabilitation should take job stress into consideration in multidisciplinary treatment strategies for severely affected OHE patients. © The Author 2014. Published by Oxford University Press on behalf of the Society of Occupational Medicine. All rights reserved. For Permissions, please email: journals.permissions@oup.com.

  7. Finite-volume cumulant expansion in QCD-colorless plasma

    Energy Technology Data Exchange (ETDEWEB)

    Ladrem, M. [Taibah University, Physics Department, Faculty of Science, Al-Madinah, Al-Munawwarah (Saudi Arabia); Physics Department, Algiers (Algeria); ENS-Vieux Kouba (Bachir El-Ibrahimi), Laboratoire de Physique et de Mathematiques Appliquees (LPMA), Algiers (Algeria); Ahmed, M.A.A. [Taibah University, Physics Department, Faculty of Science, Al-Madinah, Al-Munawwarah (Saudi Arabia); ENS-Vieux Kouba (Bachir El-Ibrahimi), Laboratoire de Physique et de Mathematiques Appliquees (LPMA), Algiers (Algeria); Taiz University in Turba, Physics Department, Taiz (Yemen); Alfull, Z.Z. [Taibah University, Physics Department, Faculty of Science, Al-Madinah, Al-Munawwarah (Saudi Arabia); Cherif, S. [ENS-Vieux Kouba (Bachir El-Ibrahimi), Laboratoire de Physique et de Mathematiques Appliquees (LPMA), Algiers (Algeria); Ghardaia University, Sciences and Technologies Department, Ghardaia (Algeria)

    2015-09-15

    Due to the finite-size effects, the localization of the phase transition in finite systems and the determination of its order, become an extremely difficult task, even in the simplest known cases. In order to identify and locate the finite-volume transition point T{sub 0}(V) of the QCD deconfinement phase transition to a colorless QGP, we have developed a new approach using the finite-size cumulant expansion of the order parameter and the L{sub mn}-method. The first six cumulants C{sub 1,2,3,4,5,6} with the corresponding under-normalized ratios (skewness Σ, kurtosis κ, pentosis Π{sub ±}, and hexosis H{sub 1,2,3}) and three unnormalized combinations of them, (O = σ{sup 2}κΣ{sup -1},U = σ{sup -2}Σ{sup -1},N = σ{sup 2}κ) are calculated and studied as functions of (T, V). A new approach, unifying in a clear and consistent way the definitions of cumulant ratios, is proposed.Anumerical FSS analysis of the obtained results has allowed us to locate accurately the finite-volume transition point. The extracted transition temperature value T{sub 0}(V) agrees with that expected T{sub 0}{sup N}(V) from the order parameter and the thermal susceptibility χ{sub T} (T, V), according to the standard procedure of localization to within about 2%. In addition to this, a very good correlation factor is obtained proving the validity of our cumulants method. The agreement of our results with those obtained by means of other models is remarkable. (orig.)

  8. Science and Societal Partnerships to Address Cumulative Impacts

    OpenAIRE

    Lundquist, Carolyn J.; Fisher, Karen T.; Le Heron, Richard; Lewis, Nick I.; Ellis, Joanne I.; Hewitt, Judi E.; Greenaway, Alison J.; Cartner, Katie J.; Burgess-Jones, Tracey C.; Schiel, David R.; Thrush, Simon F.

    2016-01-01

    Funding and priorities for ocean research are not separate from the underlying sociological, economic, and political landscapes that determine values attributed to ecological systems. Here we present a variation on science prioritization exercises, focussing on inter-disciplinary research questions with the objective of shifting broad scale management practices to better address cumulative impacts and multiple users. Marine scientists in New Zealand from a broad range of scientific and social...

  9. Cumulative prospect theory and mean variance analysis. A rigorous comparison

    OpenAIRE

    Hens, Thorsten; Mayer, Janos

    2012-01-01

    We compare asset allocations derived for cumulative prospect theory(CPT) based on two different methods: Maximizing CPT along the mean–variance efficient frontier and maximizing it without that restriction. We find that with normally distributed returns the difference is negligible. However, using standard asset allocation data of pension funds the difference is considerable. Moreover, with derivatives like call options the restriction to the mean-variance efficient frontier results in a siza...

  10. Signal anomaly detection using modified CUSUM [cumulative sum] method

    International Nuclear Information System (INIS)

    Morgenstern, V.; Upadhyaya, B.R.; Benedetti, M.

    1988-01-01

    An important aspect of detection of anomalies in signals is the identification of changes in signal behavior caused by noise, jumps, changes in band-width, sudden pulses and signal bias. A methodology is developed to identify, isolate and characterize these anomalies using a modification of the cumulative sum (CUSUM) approach. The new algorithm performs anomaly detection at three levels and is implemented on a general purpose computer. 7 refs., 4 figs

  11. Cumulative nucleon production in 3Hep- and 3Hp interactions at momenta of colliding nuclei 5 GeV/c

    International Nuclear Information System (INIS)

    Abdullin, S.K.; Blinov, A.V.; Vanyushin, I.A.

    1989-01-01

    Inclusive cross sections of cumulative protons produced in 3 Hep- and 3 Hp-interactions under momenta of colliding 5 GeV/c nuclei are investigated. Experimental material is obtained using liquid-hydrogen ITEP chamber-80cm. Under the cumulative proton kinetic energy, exceeding 50 MeV inclusive cross section ratio σ( 3 Hep→pX)/σ( 3 Hp→pX)=1.6±0.1. Within the same energy interval evaluation of yield ratio of cumulative protons and neutrons, produced in 3 Hep -interactions, leads to ∼ 1.6 value. Asymmetry of mean multiple protons escaping forward and backward both in 3 Hep -and in 3 Hp interactions is observed. Averaged invariant distribution functions for cumulative protons and neutrons in 8 Hep-interactions and protons in 3 Hp-interactions are constructed (the averaging is performed within 90-180 deg and 120-180 deg intervals). To temperatures of such distributions are found. 43 refs.; 1 fig

  12. Problems of describing the cumulative effect in relativistic nuclear physics

    International Nuclear Information System (INIS)

    Baldin, A.M.

    1979-01-01

    The problem of describing the cumulative effect i.e., the particle production on nuclei in the range kinematically forbidden for one-nucleon collisions, is studied. Discrimination of events containing cumulative particles fixes configurations in the wave function of a nucleus, when several nucleons are closely spaced and their quark-parton components are collectivized. For the cumulative processes under consideration large distances between quarks are very important. The fundamental facts and theoretical interpretation of the quantum field theory and of the condensed media theory in the relativistic nuclear physics are presented in brief. The collisions of the relativistic nuclei with low momentum transfers is considered in a fast moving coordinate system. The basic parameter determining this type of collisions is the energy of nucleon binding in nuclei. It has been shown that the short-range correlation model provides a good presentation of many characteristics of the multiple particle production and it may be regarded as an approximate universal property of hadron interactions

  13. Dynamic prediction of cumulative incidence functions by direct binomial regression.

    Science.gov (United States)

    Grand, Mia K; de Witte, Theo J M; Putter, Hein

    2018-03-25

    In recent years there have been a series of advances in the field of dynamic prediction. Among those is the development of methods for dynamic prediction of the cumulative incidence function in a competing risk setting. These models enable the predictions to be updated as time progresses and more information becomes available, for example when a patient comes back for a follow-up visit after completing a year of treatment, the risk of death, and adverse events may have changed since treatment initiation. One approach to model the cumulative incidence function in competing risks is by direct binomial regression, where right censoring of the event times is handled by inverse probability of censoring weights. We extend the approach by combining it with landmarking to enable dynamic prediction of the cumulative incidence function. The proposed models are very flexible, as they allow the covariates to have complex time-varying effects, and we illustrate how to investigate possible time-varying structures using Wald tests. The models are fitted using generalized estimating equations. The method is applied to bone marrow transplant data and the performance is investigated in a simulation study. © 2018 WILEY-VCH Verlag GmbH & Co. KGaA, Weinheim.

  14. Cumulative Risk Assessment Toolbox: Methods and Approaches for the Practitioner

    Directory of Open Access Journals (Sweden)

    Margaret M. MacDonell

    2013-01-01

    Full Text Available The historical approach to assessing health risks of environmental chemicals has been to evaluate them one at a time. In fact, we are exposed every day to a wide variety of chemicals and are increasingly aware of potential health implications. Although considerable progress has been made in the science underlying risk assessments for real-world exposures, implementation has lagged because many practitioners are unaware of methods and tools available to support these analyses. To address this issue, the US Environmental Protection Agency developed a toolbox of cumulative risk resources for contaminated sites, as part of a resource document that was published in 2007. This paper highlights information for nearly 80 resources from the toolbox and provides selected updates, with practical notes for cumulative risk applications. Resources are organized according to the main elements of the assessment process: (1 planning, scoping, and problem formulation; (2 environmental fate and transport; (3 exposure analysis extending to human factors; (4 toxicity analysis; and (5 risk and uncertainty characterization, including presentation of results. In addition to providing online access, plans for the toolbox include addressing nonchemical stressors and applications beyond contaminated sites and further strengthening resource accessibility to support evolving analyses for cumulative risk and sustainable communities.

  15. Energy Current Cumulants in One-Dimensional Systems in Equilibrium

    Science.gov (United States)

    Dhar, Abhishek; Saito, Keiji; Roy, Anjan

    2018-06-01

    A recent theory based on fluctuating hydrodynamics predicts that one-dimensional interacting systems with particle, momentum, and energy conservation exhibit anomalous transport that falls into two main universality classes. The classification is based on behavior of equilibrium dynamical correlations of the conserved quantities. One class is characterized by sound modes with Kardar-Parisi-Zhang scaling, while the second class has diffusive sound modes. The heat mode follows Lévy statistics, with different exponents for the two classes. Here we consider heat current fluctuations in two specific systems, which are expected to be in the above two universality classes, namely, a hard particle gas with Hamiltonian dynamics and a harmonic chain with momentum conserving stochastic dynamics. Numerical simulations show completely different system-size dependence of current cumulants in these two systems. We explain this numerical observation using a phenomenological model of Lévy walkers with inputs from fluctuating hydrodynamics. This consistently explains the system-size dependence of heat current fluctuations. For the latter system, we derive the cumulant-generating function from a more microscopic theory, which also gives the same system-size dependence of cumulants.

  16. Preference, resistance to change, and the cumulative decision model.

    Science.gov (United States)

    Grace, Randolph C

    2018-01-01

    According to behavioral momentum theory (Nevin & Grace, 2000a), preference in concurrent chains and resistance to change in multiple schedules are independent measures of a common construct representing reinforcement history. Here I review the original studies on preference and resistance to change in which reinforcement variables were manipulated parametrically, conducted by Nevin, Grace and colleagues between 1997 and 2002, as well as more recent research. The cumulative decision model proposed by Grace and colleagues for concurrent chains is shown to provide a good account of both preference and resistance to change, and is able to predict the increased sensitivity to reinforcer rate and magnitude observed with constant-duration components. Residuals from fits of the cumulative decision model to preference and resistance to change data were positively correlated, supporting the prediction of behavioral momentum theory. Although some questions remain, the learning process assumed by the cumulative decision model, in which outcomes are compared against a criterion that represents the average outcome value in the current context, may provide a plausible model for the acquisition of differential resistance to change. © 2018 Society for the Experimental Analysis of Behavior.

  17. Stakeholder attitudes towards cumulative and aggregate exposure assessment of pesticides.

    Science.gov (United States)

    Verbeke, Wim; Van Loo, Ellen J; Vanhonacker, Filiep; Delcour, Ilse; Spanoghe, Pieter; van Klaveren, Jacob D

    2015-05-01

    This study evaluates the attitudes and perspectives of different stakeholder groups (agricultural producers, pesticide manufacturers, trading companies, retailers, regulators, food safety authorities, scientists and NGOs) towards the concepts of cumulative and aggregate exposure assessment of pesticides by means of qualitative in-depth interviews (n = 15) and a quantitative stakeholder survey (n = 65). The stakeholders involved generally agreed that the use of chemical pesticides is needed, primarily for meeting the need of feeding the growing world population, while clearly acknowledging the problematic nature of human exposure to pesticide residues. Current monitoring was generally perceived to be adequate, but the timeliness and consistency of monitoring practices across countries were questioned. The concept of cumulative exposure assessment was better understood by stakeholders than the concept of aggregate exposure assessment. Identified pitfalls were data availability, data limitations, sources and ways of dealing with uncertainties, as well as information and training needs. Regulators and food safety authorities were perceived as the stakeholder groups for whom cumulative and aggregate pesticide exposure assessment methods and tools would be most useful and acceptable. Insights obtained from this exploratory study have been integrated in the development of targeted and stakeholder-tailored dissemination and training programmes that were implemented within the EU-FP7 project ACROPOLIS. Copyright © 2014 Elsevier Ltd. All rights reserved.

  18. Controllable dose

    International Nuclear Information System (INIS)

    Alvarez R, J.T.; Anaya M, R.A.

    2004-01-01

    With the purpose of eliminating the controversy about the lineal hypothesis without threshold which found the systems of dose limitation of the recommendations of ICRP 26 and 60, at the end of last decade R. Clarke president of the ICRP proposed the concept of Controllable Dose: as the dose or dose sum that an individual receives from a particular source which can be reasonably controllable by means of any means; said concept proposes a change in the philosophy of the radiological protection of its concern by social approaches to an individual focus. In this work a panorama of the foundations is presented, convenient and inconveniences that this proposal has loosened in the international community of the radiological protection, with the purpose of to familiarize to our Mexican community in radiological protection with these new concepts. (Author)

  19. Cancer risk of low dose/low dose rate radiation: a meta-analysis of cancer data of mammals exposed to low doses of radiation

    International Nuclear Information System (INIS)

    Ogata, Hiromitsu; Magae, Junji

    2008-01-01

    Full text: Linear No Threshold (LNT) model is a basic theory for radioprotection, but the adaptability of this hypothesis to biological responses at low doses or at low dose rates is not sufficiently investigated. Simultaneous consideration of the cumulative dose and the dose rate is necessary for evaluating the risk of long-term exposure to ionizing radiation at low dose. This study intends to examine several numerical relationships between doses and dose rates in biological responses to gamma radiation. Collected datasets on the relationship between dose and the incidence of cancer in mammals exposed to low doses of radiation were analysed using meta-regression models and modified exponential (MOE) model, which we previously published, that predicts irradiation time-dependent biological response at low dose rate ionizing radiation. Minimum doses of observable risk and effective doses with a variety of dose rates were calculated using parameters estimated by fitting meta-regression models to the data and compared them with other statistical models that find values corresponding to 'threshold limits'. By fitting a weighted regression model (fixed-effects meta-regression model) to the data on risk of all cancers, it was found that the log relative risk [log(RR)] increased as the total exposure dose increased. The intersection of this regression line with the x-axis denotes the minimum dose of observable risk. These estimated minimum doses and effective doses increased with decrease of dose rate. The goodness of fits of MOE-model depended on cancer types, but the total cancer risk is reduced when dose rates are very low. The results suggest that dose response curve for cancer risk is remarkably affected by dose rate and that dose rate effect changes as a function of dose rate. For scientific discussion on the low dose exposure risk and its uncertainty, the term 'threshold' should be statistically defined, and dose rate effects should be included in the risk

  20. Evolution of costly explicit memory and cumulative culture.

    Science.gov (United States)

    Nakamaru, Mayuko

    2016-06-21

    Humans can acquire new information and modify it (cumulative culture) based on their learning and memory abilities, especially explicit memory, through the processes of encoding, consolidation, storage, and retrieval. Explicit memory is categorized into semantic and episodic memories. Animals have semantic memory, while episodic memory is unique to humans and essential for innovation and the evolution of culture. As both episodic and semantic memory are needed for innovation, the evolution of explicit memory influences the evolution of culture. However, previous theoretical studies have shown that environmental fluctuations influence the evolution of imitation (social learning) and innovation (individual learning) and assume that memory is not an evolutionary trait. If individuals can store and retrieve acquired information properly, they can modify it and innovate new information. Therefore, being able to store and retrieve information is essential from the perspective of cultural evolution. However, if both storage and retrieval were too costly, forgetting and relearning would have an advantage over storing and retrieving acquired information. In this study, using mathematical analysis and individual-based simulations, we investigate whether cumulative culture can promote the coevolution of costly memory and social and individual learning, assuming that cumulative culture improves the fitness of each individual. The conclusions are: (1) without cumulative culture, a social learning cost is essential for the evolution of storage-retrieval. Costly storage-retrieval can evolve with individual learning but costly social learning does not evolve. When low-cost social learning evolves, the repetition of forgetting and learning is favored more than the evolution of costly storage-retrieval, even though a cultural trait improves the fitness. (2) When cumulative culture exists and improves fitness, storage-retrieval can evolve with social and/or individual learning, which

  1. El Carreto o Cumulá - Aspidosperma Dugandii Standl El Carreto o Cumulá - Aspidosperma Dugandii Standl

    Directory of Open Access Journals (Sweden)

    Dugand Armando

    1944-03-01

    Full Text Available Nombres vulgares: Carreto (Atlántico, Bolívar, Magdalena; Cumulá, Cumulá (Cundinamarca, ToIima. Según el Dr. Emilio Robledo (Lecciones de Bot. ed. 3, 2: 544. 1939 el nombre Carreto también es empleado en Puerto Berrío (Antioquia. El mismo autor (loc. cit. da el nombre Comulá para una especie indeterminada de Viburnum en Mariquita (Tolima y J. M. Duque, refiriendose a la misma planta y localidad (en Bot. Gen. Colomb. 340, 356. 1943 atribuye este nombre vulgar al Aspidosperma ellipticum Rusby.  Sin embargo, las muestras de madera de Cumulá o Comulá que yo he examinado, procedentes de la región de Mariquita -una de las cuales me fue recientemente enviada por el distinguido ictiólogo Sr. Cecil Miles- pertenecen sin duda alguna al A. Dugandii StandI. Por otra parte, Santiago Cortés (FI. Colomb. 206. 1898; ed, 2: 239. 1912 cita el Cumulá "de Anapoima y otros lugares del (rio Magdalena" diciendo que pertenece a las Leguminosas, pero la brevísima descripción que este autor hace de la madera "naranjada y notable por densidad, dureza y resistencia a la humedad", me induce a creer que se trata del mismo Cumula coleccionado recientemente en Tocaima, ya que esta población esta situada a pocos kilómetros de Anapoima. Nombres vulgares: Carreto (Atlántico, Bolívar, Magdalena; Cumulá, Cumulá (Cundinamarca, ToIima. Según el Dr. Emilio Robledo (Lecciones de Bot. ed. 3, 2: 544. 1939 el nombre Carreto también es empleado en Puerto Berrío (Antioquia. El mismo autor (loc. cit. da el nombre Comulá para una especie indeterminada de Viburnum en Mariquita (Tolima y J. M. Duque, refiriendose a la misma planta y localidad (en Bot. Gen. Colomb. 340, 356. 1943 atribuye este nombre vulgar al Aspidosperma ellipticum Rusby.  Sin embargo, las muestras de madera de Cumulá o Comulá que yo he examinado, procedentes de la región de Mariquita -una de las cuales me fue recientemente enviada por el distinguido ictiólogo Sr. Cecil Miles- pertenecen sin

  2. Multiple anatomy optimization of accumulated dose

    International Nuclear Information System (INIS)

    Watkins, W. Tyler; Siebers, Jeffrey V.; Moore, Joseph A.; Gordon, James; Hugo, Geoffrey D.

    2014-01-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated

  3. Multiple anatomy optimization of accumulated dose

    Energy Technology Data Exchange (ETDEWEB)

    Watkins, W. Tyler, E-mail: watkinswt@virginia.edu; Siebers, Jeffrey V. [Department of Radiation Oncology, University of Virginia, Charlottesville, Virginia 22908 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Moore, Joseph A. [Department of Radiation Oncology and Molecular Radiation Sciences, Johns Hopkins University, Baltimore, Maryland 21231 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Gordon, James [Henry Ford Health System, Detroit, Michigan 48202 and Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States); Hugo, Geoffrey D. [Department of Radiation Oncology, Virginia Commonwealth University, Richmond, Virginia 23298 (United States)

    2014-11-01

    Purpose: To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. Methods: MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. Results: By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. Conclusions: MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  4. Multiple anatomy optimization of accumulated dose.

    Science.gov (United States)

    Watkins, W Tyler; Moore, Joseph A; Gordon, James; Hugo, Geoffrey D; Siebers, Jeffrey V

    2014-11-01

    To investigate the potential advantages of multiple anatomy optimization (MAO) for lung cancer radiation therapy compared to the internal target volume (ITV) approach. MAO aims to optimize a single fluence to be delivered under free-breathing conditions such that the accumulated dose meets the plan objectives, where accumulated dose is defined as the sum of deformably mapped doses computed on each phase of a single four dimensional computed tomography (4DCT) dataset. Phantom and patient simulation studies were carried out to investigate potential advantages of MAO compared to ITV planning. Through simulated delivery of the ITV- and MAO-plans, target dose variations were also investigated. By optimizing the accumulated dose, MAO shows the potential to ensure dose to the moving target meets plan objectives while simultaneously reducing dose to organs at risk (OARs) compared with ITV planning. While consistently superior to the ITV approach, MAO resulted in equivalent OAR dosimetry at planning objective dose levels to within 2% volume in 14/30 plans and to within 3% volume in 19/30 plans for each lung V20, esophagus V25, and heart V30. Despite large variations in per-fraction respiratory phase weights in simulated deliveries at high dose rates (e.g., treating 4/10 phases during single fraction beams) the cumulative clinical target volume (CTV) dose after 30 fractions and per-fraction dose were constant independent of planning technique. In one case considered, however, per-phase CTV dose varied from 74% to 117% of prescription implying the level of ITV-dose heterogeneity may not be appropriate with conventional, free-breathing delivery. MAO incorporates 4DCT information in an optimized dose distribution and can achieve a superior plan in terms of accumulated dose to the moving target and OAR sparing compared to ITV-plans. An appropriate level of dose heterogeneity in MAO plans must be further investigated.

  5. Evaluation of cumulative effects of MR imaging on pacemaker systems at 1.5 Tesla.

    Science.gov (United States)

    Naehle, Claas P; Zeijlemaker, Volkert; Thomas, Daniel; Meyer, Carsten; Strach, Katharina; Fimmers, Rolf; Schild, Hans; Sommer, Torsten

    2009-12-01

    The purpose of this study was to evaluate possible cumulative effects of repeated magnetic resonance imaging (MRI) examinations on pacemaker systems in patients with cardiac pacemakers. The records of pacemaker patients who underwent repetitive MRI examinations in our institution were reviewed to identify patients who underwent two or more MRI examinations at 1.5T of any anatomical region. Using these criteria, a total of 47 patients who underwent a total 171 MRI examinations were identified and included in this study. Institutional Review Board approval for all pacemaker investigations was obtained. Written informed consent was obtained from all patients. Pacemakers were interrogated immediately before and after MR imaging, and after 3 months, including measurement of pacing capture threshold (PCT), lead impedance (LI), and battery voltage (BV). PCT, LI, and BV were analyzed for changes dependant on the number of MRI exams performed. Mean changes over time and changes between first and last pacemaker interrogation of PCT, LI, and BV were calculated. A statistically significant (P < 0.05), but clinically irrelevant trend for decrease in PCT and BV was found. No significant or clinically relevant changes in LI were observed. In this first study, no clinically relevant, cumulative changes in PCT, LI, or BV could be detected in PM patients who underwent two or more MRI examinations. However, a careful benefit/risk evaluation, among other MRI- and pacemaker-related safety precautions, remains mandatory, as clinically relevant alterations to the PM system cannot be excluded by all means.

  6. A Framework to Assess the Cumulative Hydrological Impacts of Dams on flow Regime

    Science.gov (United States)

    Wang, Y.; Wang, D.

    2016-12-01

    In this study we proposed a framework to assess the cumulative impact of dams on hydrological regime, and the impacts of the Three Gorges Dam on flow regime in Yangtze River were investigated with the framework. We reconstructed the unregulated flow series to compare with the regulated flow series in the same period. Eco-surplus and eco-deficit and the Indicators of Hydrologic Alteration parameters were used to examine the hydrological regime change. Among IHA parameters, Wilcoxon signed-rank test and Principal Components Analysis identified the representative indicators of hydrological alterations. Eco-surplus and eco-deficit showed that the reservoir also changed the seasonal regime of the flows in autumn and winter. Annual extreme flows and October flows changes lead to negative ecological implications downstream from the Three Gorges Dam. Ecological operation for the Three Gorges Dam is necessary to mitigate the negative effects on the river ecosystem in the middle reach of Yangtze River. The framework proposed here could be a robust method to assess the cumulative impacts of reservoir operation.

  7. Pill content, dose and resulting plasma concentrations of 3,4-methylendioxymethamphetamine (MDMA) in recreational 'ecstasy' users.

    Science.gov (United States)

    Morefield, Kate M; Keane, Michael; Felgate, Peter; White, Jason M; Irvine, Rodney J

    2011-07-01

    To improve our understanding of the pharmacology of 'ecstasy' in recreational environments; in particular, to describe the composition of ecstasy pills, patterns of ecstasy use and the relationship between dose of 3,4-methylendioxymethamphetamine (MDMA) and resulting plasma concentrations. A naturalistic observational study of 56 experienced 'ecstasy' users in recreational settings in Australia. Drug use patterns (number of pills consumed, other drugs consumed). drug content of pills and resultant plasma concentrations of MDMA and related drugs were assessed by gas chromatography/mass spectrometry (GC/MS). Ecstasy pills generally contained MDMA, but this was often combined with other drugs such as 3,4-ethylendioxyethylamphetamine (MDEA) and methamphetamine. The dose of MDMA per pill ranged from 0 to 245 mg and users consumed from one-half to five pills, with the total dose consumed ranging up to 280 mg. Plasma concentrations of MDMA increased with number of pills consumed and cumulative MDMA dose. Use of larger numbers of pills was associated with extended exposure to the drug. MDMA is the major active drug in ecstasy pills, but there is a high degree of variation in doses. Use of multiple pills over the course of one session is common and results in a sustained increase in MDMA plasma concentrations over a number of hours. This is likely to lead to a much greater exposure of the brain to MDMA than would be predicted from controlled single-dose pharmacokinetic studies. © 2011 The Authors, Addiction © 2011 Society for the Study of Addiction.

  8. In vivo x-ray fluorescence of lead and other toxic trace elements

    International Nuclear Information System (INIS)

    Chettle, D.R.

    1995-01-01

    The first in vivo x-ray fluorescence measurements of lead in bone used y-rays from a 57 Co source to excite Pb K x-rays. Later systems used γ-rays from 109 Cd to excite Pb K x-rays or polarized x-rays to excite Ph L x-rays. All three approaches involve an extremely low effective dose to the subject. Of the two K x-ray techniques, 109 Cd is more precise and more flexible in choice of measurement site. Pb L x-ray fluorescence (L-XRF) effectively samples lead at bone surfaces, whereas Ph K x-ray fluorescence (K-XRF) samples through the bulk of a bone. Both the polarized L-XRF and 109 Cd K-XRF achieve similar precision. Renal mercury has recently been determined using a polarized x-ray source, Both renal and hepatic cadmium can be measured using polarized x-rays in conjunction with a Si(Li) detector. Platinum and gold have been measured both by radioisotopic source excitation and by using polarized x-rays, but the latter is to be preferred. Applications of Pb K-XRF have shown that measured bone lead relates strongly to cumulative lead exposure. Secondly, biological half lives of lead in different bone types have been estimated from limited longitudinal data sets and from some cross sectional surveys. Thirdly, the effect of bone lead as an endogenous source of lead has been demonstrated and it has been shown that a majority of circulating blood lead can be mobilized from bone, rather than deriving from new exposure, in some retired lead workers. 35 refs., 5 tabs

  9. Mismatch or cumulative stress : Toward an integrated hypothesis of programming effects

    NARCIS (Netherlands)

    Nederhof, Esther; Schmidt, Mathias V.

    2012-01-01

    This paper integrates the cumulative stress hypothesis with the mismatch hypothesis, taking into account individual differences in sensitivity to programming. According to the cumulative stress hypothesis, individuals are more likely to suffer from disease as adversity accumulates. According to the

  10. Science and societal partnerships to address cumulative impacts

    Directory of Open Access Journals (Sweden)

    Carolyn J Lundquist

    2016-02-01

    Full Text Available Funding and priorities for ocean research are not separate from the underlying sociological, economic, and political landscapes that determine values attributed to ecological systems. Here we present a variation on science prioritisation exercises, focussing on inter-disciplinary research questions with the objective of shifting broad scale management practices to better address cumulative impacts and multiple users. Marine scientists in New Zealand from a broad range of scientific and social-scientific backgrounds ranked 48 statements of research priorities. At a follow up workshop, participants discussed five over-arching themes based on survey results. These themes were used to develop mechanisms to increase the relevance and efficiency of scientific research while acknowledging socio-economic and political drivers of research agendas in New Zealand’s ocean ecosystems. Overarching messages included the need to: 1 determine the conditions under which ‘surprises’ (sudden and substantive undesirable changes are likely to occur and the socio-ecological implications of such changes; 2 develop methodologies to reveal the complex and cumulative effects of change in marine systems, and their implications for resource use, stewardship, and restoration; 3 assess potential solutions to management issues that balance long-term and short-term benefits and encompass societal engagement in decision-making; 4 establish effective and appropriately resourced institutional networks to foster collaborative, solution-focused marine science; and 5 establish cross-disciplinary dialogues to translate diverse scientific and social-scientific knowledge into innovative regulatory, social and economic practice. In the face of multiple uses and cumulative stressors, ocean management frameworks must be adapted to build a collaborative framework across science, governance and society that can help stakeholders navigate uncertainties and socio-ecological surprises.

  11. Cumulative risk hypothesis: Predicting and preventing child maltreatment recidivism.

    Science.gov (United States)

    Solomon, David; Åsberg, Kia; Peer, Samuel; Prince, Gwendolyn

    2016-08-01

    Although Child Protective Services (CPS) and other child welfare agencies aim to prevent further maltreatment in cases of child abuse and neglect, recidivism is common. Having a better understanding of recidivism predictors could aid in preventing additional instances of maltreatment. A previous study identified two CPS interventions that predicted recidivism: psychotherapy for the parent, which was related to a reduced risk of recidivism, and temporary removal of the child from the parent's custody, which was related to an increased recidivism risk. However, counter to expectations, this previous study did not identify any other specific risk factors related to maltreatment recidivism. For the current study, it was hypothesized that (a) cumulative risk (i.e., the total number of risk factors) would significantly predict maltreatment recidivism above and beyond intervention variables in a sample of CPS case files and that (b) therapy for the parent would be related to a reduced likelihood of recidivism. Because it was believed that the relation between temporary removal of a child from the parent's custody and maltreatment recidivism is explained by cumulative risk, the study also hypothesized that that the relation between temporary removal of the child from the parent's custody and recidivism would be mediated by cumulative risk. After performing a hierarchical logistic regression analysis, the first two hypotheses were supported, and an additional predictor, psychotherapy for the child, also was related to reduced chances of recidivism. However, Hypothesis 3 was not supported, as risk did not significantly mediate the relation between temporary removal and recidivism. Copyright © 2016 Elsevier Ltd. All rights reserved.

  12. Analysis of the occupational doses of female radiation workers in India

    Energy Technology Data Exchange (ETDEWEB)

    Pardasani, P B; Joshi, V D; Awari, J M; Kher, R K [Bhabha Atomic Research Centre, Mumbai (India). Radiation Protection Services Div.

    1994-04-01

    Basis for control of occupational exposures of women are same as that of men except for pregnant women. Analysis of annual and cumulative occupational doses of female radiation workers as a group has been done. The average annual dose data in the four broad categories and age wise dose distribution is presented. The average working period for female radiation workers is about 3 to 5 years which is same as that of all the radiation workers on our records. The average cumulative dose for female workers is about 3 mSv. (author). 4 refs., 4 tabs.

  13. Analysis of the occupational doses of female radiation workers in India

    International Nuclear Information System (INIS)

    Pardasani, P.B.; Joshi, V.D.; Awari, J.M.; Kher, R.K.

    1994-01-01

    Basis for control of occupational exposures of women are same as that of men except for pregnant women. Analysis of annual and cumulative occupational doses of female radiation workers as a group has been done. The average annual dose data in the four broad categories and age wise dose distribution is presented. The average working period for female radiation workers is about 3 to 5 years which is same as that of all the radiation workers on our records. The average cumulative dose for female workers is about 3 mSv. (author). 4 refs., 4 tabs

  14. The proportional odds cumulative incidence model for competing risks

    DEFF Research Database (Denmark)

    Eriksson, Frank; Li, Jianing; Scheike, Thomas

    2015-01-01

    We suggest an estimator for the proportional odds cumulative incidence model for competing risks data. The key advantage of this model is that the regression parameters have the simple and useful odds ratio interpretation. The model has been considered by many authors, but it is rarely used...... in practice due to the lack of reliable estimation procedures. We suggest such procedures and show that their performance improve considerably on existing methods. We also suggest a goodness-of-fit test for the proportional odds assumption. We derive the large sample properties and provide estimators...

  15. Cumulative exposure to phthalates from phthalate-containing drug products

    DEFF Research Database (Denmark)

    Ennis, Zandra Nymand; Broe, Anne; Pottegård, Anton

    2018-01-01

    European regulatory limit of exposure ranging between 380-1710 mg/year throughout the study period. Lithium-products constituted the majority of dibutyl phthalate exposure. Diethyl phthalate exposure, mainly caused by erythromycin, theophylline and diclofenac products, did not exceed the EMA regulatory...... to quantify annual cumulated phthalate exposure from drug products among users of phthalate-containing oral medications in Denmark throughout the period of 2004-2016. METHODS: We conducted a Danish nationwide cohort study using The Danish National Prescription Registry and an internal database held...

  16. Lyapunov exponent of the random frequency oscillator: cumulant expansion approach

    International Nuclear Information System (INIS)

    Anteneodo, C; Vallejos, R O

    2010-01-01

    We consider a one-dimensional harmonic oscillator with a random frequency, focusing on both the standard and the generalized Lyapunov exponents, λ and λ* respectively. We discuss the numerical difficulties that arise in the numerical calculation of λ* in the case of strong intermittency. When the frequency corresponds to a Ornstein-Uhlenbeck process, we compute analytically λ* by using a cumulant expansion including up to the fourth order. Connections with the problem of finding an analytical estimate for the largest Lyapunov exponent of a many-body system with smooth interactions are discussed.

  17. Exact probability distribution function for the volatility of cumulative production

    Science.gov (United States)

    Zadourian, Rubina; Klümper, Andreas

    2018-04-01

    In this paper we study the volatility and its probability distribution function for the cumulative production based on the experience curve hypothesis. This work presents a generalization of the study of volatility in Lafond et al. (2017), which addressed the effects of normally distributed noise in the production process. Due to its wide applicability in industrial and technological activities we present here the mathematical foundation for an arbitrary distribution function of the process, which we expect will pave the future research on forecasting of the production process.

  18. Numerical simulation of explosive magnetic cumulative generator EMG-720

    Energy Technology Data Exchange (ETDEWEB)

    Deryugin, Yu N; Zelenskij, D K; Kazakova, I F; Kargin, V I; Mironychev, P V; Pikar, A S; Popkov, N F; Ryaslov, E A; Ryzhatskova, E G [All-Russian Research Inst. of Experimental Physics, Sarov (Russian Federation)

    1997-12-31

    The paper discusses the methods and results of numerical simulations used in the development of a helical-coaxial explosive magnetic cumulative generator (EMG) with the stator up to 720 mm in diameter. In the process of designing, separate units were numerically modeled, as was the generator operation with a constant inductive-ohmic load. The 2-D processes of the armature acceleration by the explosion products were modeled as well as those of the formation of the sliding high-current contact between the armature and stator`s insulated turns. The problem of the armature integrity in the region of the detonation waves collision was numerically analyzed. 8 figs., 2 refs.

  19. Evaluating the maximum patient radiation dose in cardiac interventional procedures

    International Nuclear Information System (INIS)

    Kato, M.; Chida, K.; Sato, T.; Oosaka, H.; Tosa, T.; Kadowaki, K.

    2011-01-01

    Many of the X-ray systems that are used for cardiac interventional radiology provide no way to evaluate the patient maximum skin dose (MSD). The authors report a new method for evaluating the MSD by using the cumulative patient entrance skin dose (ESD), which includes a back-scatter factor and the number of cine-angiography frames during percutaneous coronary intervention (PCI). Four hundred consecutive PCI patients (315 men and 85 women) were studied. The correlation between the cumulative ESD and number of cine-angiography frames was investigated. The irradiation and overlapping fields were verified using dose-mapping software. A good correlation was found between the cumulative ESD and the number of cine-angiography frames. The MSD could be estimated using the proportion of cine-angiography frames used for the main angle of view relative to the total number of cine-angiography frames and multiplying this by the cumulative ESD. The average MSD (3.0±1.9 Gy) was lower than the average cumulative ESD (4.6±2.6 Gy). This method is an easy way to estimate the MSD during PCI. (authors)

  20. Cumulative risk assessment for plasticizer-contaminated food using the hazard index approach

    International Nuclear Information System (INIS)

    Chang, J.W.; Yan, B.R.; Chang, M.H.; Tseng, S.H.; Kao, Y.M.; Chen, J.C.; Lee, C.C.

    2014-01-01

    Phthalates strongly and adversely affect reproduction, development and liver function. We did a cumulative risk assessment for simultaneous exposure to nine phthalates using the hazard index (HI) and the levels of nine phthalates in 1200 foodstuff samples. DEHP (di-2-ethylhexyl phthalate) present the highest level (mean: 0.443 mg/kg) in 1200 samples, and the highest average daily dose (ADD) was found in DEHP, ΣDBP (i + n) (the sum of dibutyl phthalate [DBP] isomers [DnBP + DiBP]) posed the highest risk potential of all the phthalates. In seven phthalates, the 95th percentiles of the ADDs for ΣDBP (i + n) in 0–6-yr-old children accounted for 91% (79–107%) of the tolerable daily intake, and the 95th percentiles of the HIs for the anti-androgenic effects of five phthalates in 0–3-yr-old children and 4–6-yr-old girls were >1. We conclude that the health of younger Taiwanese may be adversely affected by overexposure of phthalate-contaminated foods. - Graphical abstract: In seven phthalates, the 95th percentile of the average daily dose (ADD) for ΣDBP (i + n) (the sum of dibutyl phthalate [DBP] isomers [DnBP + DiBP]) in 0–3-yr-old male (0–3 M) and female (0–3 F) children accounted for 97% and 84% of TDIs, respectively. For 4–6-yr-old and 7–12-yr-old males and 7–12-yr-old females, ADDs for ΣDBP (i + n) accounted for 79%, 72%, and 65% of TDIs, respectively. - Highlights: • A cumulative risk assessment of PAEs was used in a severe plasticizer-contaminated food episode. • ΣDBP (i + n) posed the highest risk potential of all the dietary phthalates. • Females 4–6 yr old had the highest risk for anti-androgenic effects. • Beverages, milk and dairy products were the major contributors to average daily dose of phthalate esters. - The health of young Taiwanese may be adversely affected by overexposure of plasticizer-contaminated food

  1. Expansion formulae for characteristics of cumulative cost in finite horizon production models

    NARCIS (Netherlands)

    Ayhan, H.; Schlegel, S.

    2001-01-01

    We consider the expected value and the tail probability of cumulative shortage and holding cost (i.e. the probability that cumulative cost is more than a certain value) in finite horizon production models. An exact expression is provided for the expected value of the cumulative cost for general

  2. Evaluating Pharmacokinetic and Pharmacodynamic Interactions with Computational Models in Supporting Cumulative Risk Assessment

    Science.gov (United States)

    Tan, Yu-Mei; Clewell, Harvey; Campbell, Jerry; Andersen, Melvin

    2011-01-01

    Simultaneous or sequential exposure to multiple chemicals may cause interactions in the pharmacokinetics (PK) and/or pharmacodynamics (PD) of the individual chemicals. Such interactions can cause modification of the internal or target dose/response of one chemical in the mixture by other chemical(s), resulting in a change in the toxicity from that predicted from the summation of the effects of the single chemicals using dose additivity. In such cases, conducting quantitative cumulative risk assessment for chemicals present as a mixture is difficult. The uncertainties that arise from PK interactions can be addressed by developing physiologically based pharmacokinetic (PBPK) models to describe the disposition of chemical mixtures. Further, PK models can be developed to describe mechanisms of action and tissue responses. In this article, PBPK/PD modeling efforts conducted to investigate chemical interactions at the PK and PD levels are reviewed to demonstrate the use of this predictive modeling framework in assessing health risks associated with exposures to complex chemical mixtures. PMID:21655141

  3. Spiral CT and radiation dose

    International Nuclear Information System (INIS)

    Imhof, H.; Schibany, N.; Ba-Ssalamah, A.; Czerny, C.; Hojreh, A.; Kainberger, F.; Krestan, C.; Kudler, H.; Noebauer, I.; Nowotny, R.

    2003-01-01

    Recent studies in the USA and Europe state that computed tomography (CT) scans compromise only 3-5% of all radiological exams, but they contribute 35-45% of total radiation dose to the patient population. These studies lead to concern by several public authorities. Basis of CT-dose measurements is the computed tomography dose index (CTDI), which was established 1981. Nowadays there are several modifications of the CTDI values, which may lead to confusion. It is suggested to use the standardized CTDI-100 w. value together with the dose length product in all CT-examinations. These values should be printed on all CT-images and allows an evaluation of the individualized patient dose. Nowadays, radiologist's aim must be to work at the lowest maximal diagnostic acceptable signal to noise ratio. To decrease radiation dose radiologist should use low kV and mA, but high pitches. Newly developed CT-dose-reduction soft-wares and filters should be installed in all CT-machines. We should critically compare the average dose used for a specific examination with the reference dose used in this country and/or Europe. Greater differences should caution the radiologist. Finally, we as radiologists must check very carefully all indications and recommend alternative imaging methods. But we have also to teach our customers--patients and medical doctors who are non-radiologists--that a 'good' image is not that which show all possible information, but that which visualize 'only' the diagnostic necessary information

  4. Assessment of radiation doses due to normal operation, incidents and accidents of the final disposal facility

    International Nuclear Information System (INIS)

    Rossi, J.; Raiko, H.; Suolanen, V.; Ilvonen, M.

    1999-03-01

    Radiation doses for workers of the encapsulation and disposal facility and for inhabitants in the environment caused by the facility during its operation were considered. The study covers both the normal operation of the plant and some hypothetical incidents and accidents. Occupational radiation doses inside the plant during normal operation are based on the design basis, assuming that highest permitted dose levels are prevailing in control rooms during fuel transfer and encapsulation processes. Release through the ventilation stack is assumed to be filtered both in normal operation and in hypothetical incident and accident cases. Calculation of the offsite doses from normal operation is based on the hypothesis that one fuel pin per 100 fuel bundles for all batches of spent fuel transported to the encapsulation facility is leaking. The release magnitude in incidents and accidents is based on the event chains, which lead to loss of fuel pin tightness followed by a discharge of radionuclides into the handling chamber and to some degree through the ventilation stack into atmosphere. The weather data measured at the Olkiluoto meteorological mast was employed for calculating of offsite doses. Therefore doses could be calculated in a large amount of different dispersion conditions, the statistical frequencies of which have, been measured. Finally doses were combined into cumulative distributions, from which a dose value representing the 99.5 % confidence level, is presented. The dose values represent the exposure of a critical group, which is assumed to live at the distance of 200 meters from the encapsulation and disposal plant and thus it will receive the largest doses in most dispersion conditions. Exposure pathways considered were: cloudsnine, inhalation, groundshine and nutrition (milk of cow, meat of cow, green vegetables, grain and root vegetables). Nordic seasonal variation is included in ingestion dose models. The results obtained indicate that offsite doses

  5. Dose and dose rate monitor

    International Nuclear Information System (INIS)

    Novakova, O.; Ryba, J.; Slezak, V.; Svobodova, B.; Viererbl, L.

    1984-10-01

    The methods are discussea of measuring dose rate or dose using a scintillation counte. A plastic scintillator based on polystyrene with PBD and POPOP activators and coated with ZnS(Ag) was chosen for the projected monitor. The scintillators were cylindrical and spherical in shape and of different sizes; black polypropylene tubes were chosen as the best case for the probs. For the counter with different plastic scintillators, the statistical error 2σ for natural background was determined. For determining the suitable thickness of the ZnS(Ag) layer the energy dependence of the counter was measured. Radioisotopes 137 Cs, 241 Am and 109 Cd were chosen as radiation sources. The best suited ZnS(Ag) thickness was found to be 0.5 μm. Experiments were carried out to determine the directional dependence of the detector response and the signal to noise ratio. The temperature dependence of the detector response and its compensation were studied, as were the time stability and fatigue manifestations of the photomultiplier. The design of a laboratory prototype of a dose rate and dose monitor is described. Block diagrams are given of the various functional parts of the instrument. The designed instrument is easiiy portable, battery powered, measures dose rates from natural background in the range of five orders, i.e., 10 -2 to 10 3 nGy/s, and allows to determine a dose of up to 10 mGy. Accouracy of measurement in the energy range of 50 keV to 1 MeV is better than +-20%. (E.S.)

  6. Activation of Antibiotic Production in Bacillus spp. by Cumulative Drug Resistance Mutations.

    Science.gov (United States)

    Tojo, Shigeo; Tanaka, Yukinori; Ochi, Kozo

    2015-12-01

    Bacillus subtilis strains produce a wide range of antibiotics, including ribosomal and nonribosomal peptide antibiotics, as well as bacilysocin and neotrehalosadiamine. Mutations in B. subtilis strain 168 that conferred resistance to drugs such as streptomycin and rifampin resulted in overproduction of the dipeptide antibiotic bacilysin. Cumulative drug resistance mutations, such as mutations in the mthA and rpsL genes, which confer low- and high-level resistance, respectively, to streptomycin, and mutations in rpoB, which confer resistance to rifampin, resulted in cells that overproduced bacilysin. Transcriptional analysis demonstrated that the enhanced transcription of biosynthesis genes was responsible for the overproduction of bacilysin. This approach was effective also in activating the cryptic genes of Bacillus amyloliquefaciens, leading to actual production of antibiotic(s). Copyright © 2015, American Society for Microbiology. All Rights Reserved.

  7. Cumulative distribution functions associated with bubble-nucleation processes in cavitation

    KAUST Repository

    Watanabe, Hiroshi

    2010-11-15

    Bubble-nucleation processes of a Lennard-Jones liquid are studied by molecular dynamics simulations. Waiting time, which is the lifetime of a superheated liquid, is determined for several system sizes, and the apparent finite-size effect of the nucleation rate is observed. From the cumulative distribution function of the nucleation events, the bubble-nucleation process is found to be not a simple Poisson process but a Poisson process with an additional relaxation time. The parameters of the exponential distribution associated with the process are determined by taking the relaxation time into account, and the apparent finite-size effect is removed. These results imply that the use of the arithmetic mean of the waiting time until a bubble grows to the critical size leads to an incorrect estimation of the nucleation rate. © 2010 The American Physical Society.

  8. Cumulant-Based Coherent Signal Subspace Method for Bearing and Range Estimation

    Directory of Open Access Journals (Sweden)

    Bourennane Salah

    2007-01-01

    Full Text Available A new method for simultaneous range and bearing estimation for buried objects in the presence of an unknown Gaussian noise is proposed. This method uses the MUSIC algorithm with noise subspace estimated by using the slice fourth-order cumulant matrix of the received data. The higher-order statistics aim at the removal of the additive unknown Gaussian noise. The bilinear focusing operator is used to decorrelate the received signals and to estimate the coherent signal subspace. A new source steering vector is proposed including the acoustic scattering model at each sensor. Range and bearing of the objects at each sensor are expressed as a function of those at the first sensor. This leads to the improvement of object localization anywhere, in the near-field or in the far-field zone of the sensor array. Finally, the performances of the proposed method are validated on data recorded during experiments in a water tank.

  9. Cumulative hierarchies and computability over universes of sets

    Directory of Open Access Journals (Sweden)

    Domenico Cantone

    2008-05-01

    Full Text Available Various metamathematical investigations, beginning with Fraenkel’s historical proof of the independence of the axiom of choice, called for suitable definitions of hierarchical universes of sets. This led to the discovery of such important cumulative structures as the one singled out by von Neumann (generally taken as the universe of all sets and Godel’s universe of the so-called constructibles. Variants of those are exploited occasionally in studies concerning the foundations of analysis (according to Abraham Robinson’s approach, or concerning non-well-founded sets. We hence offer a systematic presentation of these many structures, partly motivated by their relevance and pervasiveness in mathematics. As we report, numerous properties of hierarchy-related notions such as rank, have been verified with the assistance of the ÆtnaNova proof-checker.Through SETL and Maple implementations of procedures which effectively handle the Ackermann’s hereditarily finite sets, we illustrate a particularly significant case among those in which the entities which form a universe of sets can be algorithmically constructed and manipulated; hereby, the fruitful bearing on pure mathematics of cumulative set hierarchies ramifies into the realms of theoretical computer science and algorithmics.

  10. Cumulative Effects Assessment: Linking Social, Ecological, and Governance Dimensions

    Directory of Open Access Journals (Sweden)

    Marian Weber

    2012-06-01

    Full Text Available Setting social, economic, and ecological objectives is ultimately a process of social choice informed by science. In this special feature we provide a multidisciplinary framework for the use of cumulative effects assessment in land use planning. Forest ecosystems are facing considerable challenges driven by population growth and increasing demands for resources. In a suite of case studies that span the boreal forest of Western Canada to the interior Atlantic forest of Paraguay we show how transparent and defensible methods for scenario analysis can be applied in data-limited regions and how social dimensions of land use change can be incorporated in these methods, particularly in aboriginal communities that have lived in these ecosystems for generations. The case studies explore how scenario analysis can be used to evaluate various land use options and highlight specific challenges with identifying social and ecological responses, determining thresholds and targets for land use, and integrating local and traditional knowledge in land use planning. Given that land use planning is ultimately a value-laden and often politically charged process we also provide some perspective on various collective and expert-based processes for identifying cumulative impacts and thresholds. The need for good science to inform and be informed by culturally appropriate democratic processes calls for well-planned and multifaceted approaches both to achieve an informed understanding of both residents and governments of the interactive and additive changes caused by development, and to design action agendas to influence such change at the ecological and social level.

  11. Maternal distress and parenting in the context of cumulative disadvantage.

    Science.gov (United States)

    Arditti, Joyce; Burton, Linda; Neeves-Botelho, Sara

    2010-06-01

    This article presents an emergent conceptual model of the features and links between cumulative disadvantage, maternal distress, and parenting practices in low-income families in which parental incarceration has occurred. The model emerged from the integration of extant conceptual and empirical research with grounded theory analysis of longitudinal ethnographic data from Welfare, Children, and Families: A Three-City Study. Fourteen exemplar family cases were used in the analysis. Results indicated that mothers in these families experienced life in the context of cumulative disadvantage, reporting a cascade of difficulties characterized by neighborhood worries, provider concerns, bureaucratic difficulties, violent intimate relationships, and the inability to meet children's needs. Mothers, however, also had an intense desire to protect their children, and to make up for past mistakes. Although, in response to high levels of maternal distress and disadvantage, most mothers exhibited harsh discipline of their children, some mothers transformed their distress by advocating for their children under difficult circumstances. Women's use of harsh discipline and advocacy was not necessarily an "either/or" phenomenon as half of the mothers included in our analysis exhibited both harsh discipline and care/advocacy behaviors. Maternal distress characterized by substance use, while connected to harsh disciplinary behavior, did not preclude mothers engaging in positive parenting behaviors.

  12. Cumulative phase delay imaging for contrast-enhanced ultrasound tomography

    International Nuclear Information System (INIS)

    Demi, Libertario; Van Sloun, Ruud J G; Wijkstra, Hessel; Mischi, Massimo

    2015-01-01

    Standard dynamic-contrast enhanced ultrasound (DCE-US) imaging detects and estimates ultrasound-contrast-agent (UCA) concentration based on the amplitude of the nonlinear (harmonic) components generated during ultrasound (US) propagation through UCAs. However, harmonic components generation is not specific to UCAs, as it also occurs for US propagating through tissue. Moreover, nonlinear artifacts affect standard DCE-US imaging, causing contrast to tissue ratio reduction, and resulting in possible misclassification of tissue and misinterpretation of UCA concentration. Furthermore, no contrast-specific modality exists for DCE-US tomography; in particular speed-of-sound changes due to UCAs are well within those caused by different tissue types. Recently, a new marker for UCAs has been introduced. A cumulative phase delay (CPD) between the second harmonic and fundamental component is in fact observable for US propagating through UCAs, and is absent in tissue. In this paper, tomographic US images based on CPD are for the first time presented and compared to speed-of-sound US tomography. Results show the applicability of this marker for contrast specific US imaging, with cumulative phase delay imaging (CPDI) showing superior capabilities in detecting and localizing UCA, as compared to speed-of-sound US tomography. Cavities (filled with UCA) which were down to 1 mm in diameter were clearly detectable. Moreover, CPDI is free of the above mentioned nonlinear artifacts. These results open important possibilities to DCE-US tomography, with potential applications to breast imaging for cancer localization. (fast track communication)

  13. Cumulant expansions for measuring water exchange using diffusion MRI

    Science.gov (United States)

    Ning, Lipeng; Nilsson, Markus; Lasič, Samo; Westin, Carl-Fredrik; Rathi, Yogesh

    2018-02-01

    The rate of water exchange across cell membranes is a parameter of biological interest and can be measured by diffusion magnetic resonance imaging (dMRI). In this work, we investigate a stochastic model for the diffusion-and-exchange of water molecules. This model provides a general solution for the temporal evolution of dMRI signal using any type of gradient waveform, thereby generalizing the signal expressions for the Kärger model. Moreover, we also derive a general nth order cumulant expansion of the dMRI signal accounting for water exchange, which has not been explored in earlier studies. Based on this analytical expression, we compute the cumulant expansion for dMRI signals for the special case of single diffusion encoding (SDE) and double diffusion encoding (DDE) sequences. Our results provide a theoretical guideline on optimizing experimental parameters for SDE and DDE sequences, respectively. Moreover, we show that DDE signals are more sensitive to water exchange at short-time scale but provide less attenuation at long-time scale than SDE signals. Our theoretical analysis is also validated using Monte Carlo simulations on synthetic structures.

  14. Strategy for an assessment of cumulative ecological impacts

    International Nuclear Information System (INIS)

    Boucher, P.; Collins, J.; Nelsen, J.

    1995-01-01

    The US Department of Energy (DOE) has developed a strategy to conduct an assessment of the cumulative ecological impact of operations at the 300-square-mile Savannah River Site. This facility has over 400 identified waste units and contains several large watersheds. In addition to individual waste units, residual contamination must be evaluated in terms of its contribution to ecological risks at zonal and site-wide levels. DOE must be able to generate sufficient information to facilitate cleanup in the immediate future within the context of a site-wide ecological risk assessment that may not be completed for many years. The strategy superimposes a more global perspective on ecological assessments of individual waste units and provides strategic underpinnings for conducting individual screening-level and baseline risk assessments at the operable unit and zonal or watershed levels. It identifies ecological endpoints and risk assessment tools appropriate for each level of the risk assessment. In addition, it provides a clear mechanism for identifying clean sites through screening-level risk assessments and for elevating sites with residual contamination to the next level of assessment. Whereas screening-level and operable unit-level risk assessments relate directly to cleanup, zonal and site-wide assessments verity or confirm the overall effectiveness of remediation. The latter assessments must show, for example, whether multiple small areas with residual pesticide contamination that have minimal individual impact would pose a cumulative risk from bioaccumulation because they are within the habitat range of an ecological receptor

  15. Lead in calcium supplements (abstract)

    International Nuclear Information System (INIS)

    Rehman, S.; Khalid, N.

    2011-01-01

    Lead present in calcium supplements is of grave concern as some lead levels have been measured up to the extent of regulatory limit set by the United States. Calcium supplements inevitably get contaminated with lead as both are naturally occurring elements. Therefore, it is imperative to indicate its level in these supplements in order to create awareness among consumers. In this study, a sophisticated analytical technique, atomic absorption spectrometry was used to analyze Pb contents in 27 commonly consumed Ca supplements manufactured by different national and multinational companies. The daily intake of lead through these supplements was calculated. Only 10% of the calcium supplements analyzed met the criteria of acceptable Pb levels (1.5 mu g/daily dose) in supplements/consumer products set by the United States. It was also found that Pb intake was highest in chelated calcium supplements 28.5 mu g/daily dose, whereas lowest 0.47 mu g/daily dose through calcium supplements with vitamin D formulation. In order to validate our results from the study conducted, IAEA-certified reference material (animal bone, H-5) was analyzed for its Pb levels. The levels of Pb determined were quite in good agreement with the certified values. (author)

  16. Cumulative effects of road de-icing salt on amphibian behavior.

    Science.gov (United States)

    Denoël, Mathieu; Bichot, Marion; Ficetola, Gentile Francesco; Delcourt, Johann; Ylieff, Marc; Kestemont, Patrick; Poncin, Pascal

    2010-08-15

    Despite growing evidence of the detrimental effect of chemical substances on organisms, limited research has focused on changes in behavioral patterns, in part due to the difficulties to obtain detailed quantitative data. Recent developments in efficient computer-based video analyses have allowed testing pesticide effects on model species such as the zebrafish. However, these new techniques have not yet been applied to amphibians and directly to conservation issues, i.e., to assess toxicological risks on threatened species. We used video-tracking analyses to test a quantitative effect of an environmental contaminant on the locomotion of amphibian tadpoles (Rana temporaria) by taking into account cumulative effects. Because recent research has demonstrated effects of de-icing salts on survival and community structure, we used sodium chloride in our experimental design (25 replicates, 4 concentrations, 4 times) to test for an effect at the scale of behavior at environmentally relevant concentrations. Analysis of 372 1-h video-tracks (5 samples/s) showed a complex action of salts on behavioral patterns with a dose and cumulative response over time. Although no effects were found on mortality or growth, the highest salt concentrations reduced the speed and movement of tadpoles in comparison with control treatments. The reduced locomotor performance could have detrimental consequences in terms of tadpoles' responses to competition and predation and may be an indicator of the low concentration effect of the contaminant. On one hand, this study demonstrates the usefulness of examining behavior to address conservation issues and understand the complex action of environmental factors and, more particularly, pollutants on organisms. On the other hand, our results highlight the need of new computerized techniques to quantitatively analyze these patterns. (c) 2010 Elsevier B.V. All rights reserved.

  17. [Analysis of the cumulative solar ultraviolet radiation in Mexico].

    Science.gov (United States)

    Castanedo-Cázares, Juan Pablo; Torres-Álvarez, Bertha; Portales-González, Bárbara; Martínez-Rosales, Karla; Hernández-Blanco, Diana

    2016-01-01

    The incidence of skin cancer has increased in Mexico in recent years. Ultraviolet radiation is the main risk factor associated. Due to the need to develop strategies to prevent skin cancer, the aim of the study was to estimate the UV intensity in several representative regions of Mexico, the average annual UV dose of these populations, and the potential benefit of applying sunscreen at different ages. The intensity of UV radiation was quantified by remote and terrestrial radiometry. The dose of UV exposure was measured in minimal erythema doses using validated models for face and arms. The benefit of using a sunscreen was calculated with the use of a sunscreen with SPF 15 from birth to age 70. The UV radiation is lower in December and greater in the period from May to July. The region with a lower annual dose is Tijuana; and the higher annual dose is in the Mexico City area. The annual difference between these regions was 58 %. Through life, a low SPF sunscreen can reduce up to 66 % of the received UV dose. The geographical location is a risk factor for accumulation of UV radiation in Mexico. Since childhood, people receive high amounts of it; however, most of this dose can be reduced using any commercially available sunscreen, if applied strategically.

  18. Considerations on absorbed dose estimates based on different β-dose point kernels in internal dosimetry

    International Nuclear Information System (INIS)

    Uchida, Isao; Yamada, Yasuhiko; Yamashita, Takashi; Okigaki, Shigeyasu; Oyamada, Hiyoshimaru; Ito, Akira.

    1995-01-01

    In radiotherapy with radiopharmaceuticals, more accurate estimates of the three-dimensional (3-D) distribution of absorbed dose is important in specifying the activity to be administered to patients to deliver a prescribed absorbed dose to target volumes without exceeding the toxicity limit of normal tissues in the body. A calculation algorithm for the purpose has already been developed by the authors. An accurate 3-D distribution of absorbed dose based on the algorithm is given by convolution of the 3-D dose matrix for a unit cubic voxel containing unit cumulated activity, which is obtained by transforming a dose point kernel into a 3-D cubic dose matrix, with the 3-D cumulated activity distribution given by the same voxel size. However, beta-dose point kernels affecting accurate estimates of the 3-D absorbed dose distribution have been different among the investigators. The purpose of this study is to elucidate how different beta-dose point kernels in water influence on the estimates of the absorbed dose distribution due to the dose point kernel convolution method by the authors. Computer simulations were performed using the MIRD thyroid and lung phantoms under assumption of uniform activity distribution of 32 P. Using beta-dose point kernels derived from Monte Carlo simulations (EGS-4 or ACCEPT computer code), the differences among their point kernels gave little differences for the mean and maximum absorbed dose estimates for the MIRD phantoms used. In the estimates of mean and maximum absorbed doses calculated using different cubic voxel sizes (4x4x4 mm and 8x8x8 mm) for the MIRD thyroid phantom, the maximum absorbed doses for the 4x4x4 mm-voxel were estimated approximately 7% greater than the cases of the 8x8x8 mm-voxel. They were found in every beta-dose point kernel used in this study. On the other hand, the percentage difference of the mean absorbed doses in the both voxel sizes for each beta-dose point kernel was less than approximately 0.6%. (author)

  19. Cumulative effects in Swedish EIA practice - difficulties and obstacles

    International Nuclear Information System (INIS)

    Waernbaeck, Antoienette; Hilding-Rydevik, Tuija

    2009-01-01

    The importance of considering cumulative effects (CE) in the context of environmental assessment is manifested in the EU regulations. The demands on the contents of Environmental Impact Assessment (EIA) and Strategic Environmental Assessment (SEA) documents explicitly ask for CE to be described. In Swedish environmental assessment documents CE are rarely described or included. The aim of this paper is to look into the reasons behind this fact in the Swedish context. The paper describes and analyse how actors implementing the EIA and SEA legislation in Sweden perceive the current situation in relation to the legislative demands and the inclusion of cumulative effects. Through semi-structured interviews the following questions have been explored: Is the phenomenon of CE discussed and included in the EIA/SEA process? What do the actors include in and what is their knowledge of the term and concept of CE? Which difficulties and obstacles do these actors experience and what possibilities for inclusion of CE do they see in the EIA/SEA process? A large number of obstacles and hindrances emerged from the interviews conducted. It can be concluded from the analysis that the will to act does seem to exist. A lack of knowledge in respect of how to include cumulative effects and a lack of clear regulations concerning how this should be done seem to be perceived as the main obstacles. The knowledge of the term and the phenomenon is furthermore quite narrow and not all encompassing. They experience that there is a lack of procedures in place. They also seem to lack knowledge of methods in relation to how to actually work, in practice, with CE and how to include CE in the EIA/SEA process. It can be stated that the existence of this poor picture in relation to practice concerning CE in the context of impact assessment mirrors the existing and so far rather vague demands in respect of the inclusion and assessment of CE in Swedish EIA and SEA legislation, regulations, guidelines and

  20. Is Dose Deformation–Invariance Hypothesis Verified in Prostate IGRT?

    Energy Technology Data Exchange (ETDEWEB)

    Simon, Antoine, E-mail: antoine.simon@univ-rennes1.fr [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Le Maitre, Amandine; Nassef, Mohamed; Rigaud, Bastien [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Castelli, Joël [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Department of Radiotherapy, Centre Eugène Marquis, 35000 Rennes (France); Acosta, Oscar; Haigron, Pascal [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Lafond, Caroline; Crevoisier, Renaud de [INSERM, U1099, 35000 Rennes (France); Laboratoire Traitement du Signal et de l' Image, Université de Rennes 1, 35000 Rennes (France); Department of Radiotherapy, Centre Eugène Marquis, 35000 Rennes (France)

    2017-03-15

    Purpose: To assess dose uncertainties resulting from the dose deformation–invariance hypothesis in prostate cone beam computed tomography (CT)–based image guided radiation therapy (IGRT), namely to evaluate whether rigidly propagated planned dose distribution enables good estimation of fraction dose distributions. Methods and Materials: Twenty patients underwent a CT scan for planning intensity modulated radiation therapy–IGRT delivering 80 Gy to the prostate, followed by weekly CT scans. Two methods were used to obtain the dose distributions on the weekly CT scans: (1) recalculating the dose using the original treatment plan; and (2) rigidly propagating the planned dose distribution. The cumulative doses were then estimated in the organs at risk for each dose distribution by deformable image registration. The differences between recalculated and propagated doses were finally calculated for the fraction and the cumulative dose distributions, by use of per-voxel and dose-volume histogram (DVH) metrics. Results: For the fraction dose, the mean per-voxel absolute dose difference was <1 Gy for 98% and 95% of the fractions for the rectum and bladder, respectively. The maximum dose difference within 1 voxel reached, however, 7.4 Gy in the bladder and 8.0 Gy in the rectum. The mean dose differences were correlated with gas volume for the rectum and patient external contour variations for the bladder. The mean absolute differences for the considered volume receiving greater than or equal to dose x (V{sub x}) of the DVH were between 0.37% and 0.70% for the rectum and between 0.53% and 1.22% for the bladder. For the cumulative dose, the mean differences in the DVH were between 0.23% and 1.11% for the rectum and between 0.55% and 1.66% for the bladder. The largest dose difference was 6.86%, for bladder V{sub 80Gy}. The mean dose differences were <1.1 Gy for the rectum and <1 Gy for the bladder. Conclusions: The deformation–invariance hypothesis was

  1. Dose volume assessment of high dose rate 192IR endobronchial implants

    International Nuclear Information System (INIS)

    Cheng, B. Saw; Korb, Leroy J.; Pawlicki, Todd; Wu, Andrew

    1996-01-01

    Purpose: To study the dose distributions of high dose rate (HDR) endobronchial implants using the dose nonuniformity ratio (DNR) and three volumetric irradiation indices. Methods and Materials: Multiple implants were configured by allowing a single HDR 192 Ir source to step through a length of 6 cm along an endobronchial catheter. Dwell times were computed to deliver a dose of 5 Gy to points 1 cm away from the catheter axis. Five sets of source configurations, each with different dwell position spacings from 0.5 to 3.0 cm, were evaluated. Three-dimensional (3D) dose distributions were then generated for each source configuration. Differential and cumulative dose-volume curves were generated to quantify the degree of target volume coverage, dose nonuniformity within the target volume, and irradiation of tissues outside the target volume. Evaluation of the implants were made using the DNR and three volumetric irradiation indices. Results: The observed isodose distributions were not able to satisfy all the dose constraints. The ability to optimally satisfy the dose constraints depended on the choice of dwell position spacing and the specification of the dose constraint points. The DNR and irradiation indices suggest that small dwell position spacing does not result in a more homogeneous dose distribution for the implant. This study supports the existence of a relationship between the dwell position spacing and the distance from the catheter axis to the reference dose or dose constraint points. Better dose homogeneity for an implant can be obtained if the spacing of the dwell positions are about twice the distance from the catheter axis to the reference dose or dose constraint points

  2. Influência de doses crescentes de chumbo sobre o teor e o conteúdo de nutrientes e Pb em mudas de ipê-roxo (Tabebuia impetiginosa (Mart. Standl. Influence of increasing lead levels on nutrient and Pb content and accumulation in ipê-roxo (Tabebuia impetiginosa (Mart. Standl. seedlings

    Directory of Open Access Journals (Sweden)

    Haroldo Nogueira de Paiva

    2003-04-01

    Full Text Available O efeito da aplicação de chumbo sobre o teor e o conteúdo de nutrientes e Pb na raiz, no caule e nas folhas de mudas de ipê-roxo (Tabebuia impetiginosa (Mart. Standl. foi estudado em um experimento realizado em casa de vegetação do Departamento de Ciência do Solo da Universidade Federal de Lavras. As mudas foram cultivadas em solução nutritiva de Clark e submetidas a doses crescentes de Pb: 0, 48, 96, 192 e 288 mimol/l. O experimento foi conduzido em delineamento estatístico de blocos ao acaso, e após 60 dias de exposição ao metal pesado foram feitas avaliações do teor e do conteúdo de macro, micronutrientes e chumbo na matéria seca de raiz, caule e folha. Os resultados mostraram que a aplicação de chumbo aumentou o teor de P e praticamente não afetou os teores de S, Ca e Mg nas mudas. De modo geral os teores de Cu, Fe e Mn sofreram redução, o teor de Zn não foi afetado, enquanto o conteúdo de macro e de micronutrientes sofreu redução. O teor de Pb na matéria seca de raiz, caule e folha aumentou com as doses aplicadas, principalmente na raiz, e se mostrou pouco móvel nas plantas analisadas.The effect of lead application on nutrient and Pb content and accumulation in ipê-roxo (Tabebuia impetiginosa (Mart. Standl. seedlings was studied in an experiment conducted under greenhouse conditions at the Soil Science Department of the Federal University of Lavras. The seedlings were cultivated in Clark nutrient solution and submitted to increasing Pb levels: 0, 48, 96, 192 and 288 mumol/l. The experiment was arranged in a randomized block design and after 60 days of exposure to the heavy metals, evaluations of macro and micronutrient and lead content and accumulation in the root, stem and leaf dry matter were made. The results showed that lead application increased P content and practically did not affect S, Ca and Mg contents. Cu, Fe and Mn contents, in general, presented a reduction; Zn content was not affected while macro

  3. Cumulative trauma and symptom complexity in children: a path analysis.

    Science.gov (United States)

    Hodges, Monica; Godbout, Natacha; Briere, John; Lanktree, Cheryl; Gilbert, Alicia; Kletzka, Nicole Taylor

    2013-11-01

    Multiple trauma exposures during childhood are associated with a range of psychological symptoms later in life. In this study, we examined whether the total number of different types of trauma experienced by children (cumulative trauma) is associated with the complexity of their subsequent symptomatology, where complexity is defined as the number of different symptom clusters simultaneously elevated into the clinical range. Children's symptoms in six different trauma-related areas (e.g., depression, anger, posttraumatic stress) were reported both by child clients and their caretakers in a clinical sample of 318 children. Path analysis revealed that accumulated exposure to multiple different trauma types predicts symptom complexity as reported by both children and their caretakers. Copyright © 2013 Elsevier Ltd. All rights reserved.

  4. Near-Field Source Localization Using a Special Cumulant Matrix

    Science.gov (United States)

    Cui, Han; Wei, Gang

    A new near-field source localization algorithm based on a uniform linear array was proposed. The proposed algorithm estimates each parameter separately but does not need pairing parameters. It can be divided into two important steps. The first step is bearing-related electric angle estimation based on the ESPRIT algorithm by constructing a special cumulant matrix. The second step is the other electric angle estimation based on the 1-D MUSIC spectrum. It offers much lower computational complexity than the traditional near-field 2-D MUSIC algorithm and has better performance than the high-order ESPRIT algorithm. Simulation results demonstrate that the performance of the proposed algorithm is close to the Cramer-Rao Bound (CRB).

  5. Cumulative growth of minor hysteresis loops in the Kolmogorov model

    International Nuclear Information System (INIS)

    Meilikhov, E. Z.; Farzetdinova, R. M.

    2013-01-01

    The phenomenon of nonrepeatability of successive remagnetization cycles in Co/M (M = Pt, Pd, Au) multilayer film structures is explained in the framework of the Kolmogorov crystallization model. It is shown that this model of phase transitions can be adapted so as to adequately describe the process of magnetic relaxation in the indicated systems with “memory.” For this purpose, it is necessary to introduce some additional elements into the model, in particular, (i) to take into account the fact that every cycle starts from a state “inherited” from the preceding cycle and (ii) to assume that the rate of growth of a new magnetic phase depends on the cycle number. This modified model provides a quite satisfactory qualitative and quantitative description of all features of successive magnetic relaxation cycles in the system under consideration, including the surprising phenomenon of cumulative growth of minor hysteresis loops.

  6. Cumulative protons in 12C fragmentation at intermediate energy

    International Nuclear Information System (INIS)

    Abramov, B.M.; Alekseev, P.N.; Borodin, Y.A.; Bulychjov, S.A.; Dukhovskoi, I.A.; Khanov, A.I.; Krutenkova, A.P.; Kulikov, V.V.; Martemianov, M.A.; Matsuk, M.A.; Turdakina, E.N.

    2014-01-01

    In the FRAGM experiment at heavy ion accelerator complex TWAC-ITEP, the proton yields at an angle 3.5 degrees have been measured in fragmentation of carbon ions at T 0 equals 0.3, 0.6, 0.95 and 2.0 GeV/nucleon on beryllium target. The data are presented as invariant proton yields on cumulative variable x in the range 0.9 < x < 2.4. Proton spectra cover six orders of invariant cross section magnitude. They have been analyzed in the framework of quark cluster fragmentation model. Fragmentation functions of quark- gluon string model are used. The probabilities of the existence of multi-quark clusters in carbon nuclei are estimated to be 8 - 12% for six-quark clusters and 0.2 - 0.6% for nine- quark clusters. (authors)

  7. EXPERIMENTAL VALIDATION OF CUMULATIVE SURFACE LOCATION ERROR FOR TURNING PROCESSES

    Directory of Open Access Journals (Sweden)

    Adam K. Kiss

    2016-02-01

    Full Text Available The aim of this study is to create a mechanical model which is suitable to investigate the surface quality in turning processes, based on the Cumulative Surface Location Error (CSLE, which describes the series of the consecutive Surface Location Errors (SLE in roughing operations. In the established model, the investigated CSLE depends on the currently and the previously resulted SLE by means of the variation of the width of cut. The phenomenon of the system can be described as an implicit discrete map. The stationary Surface Location Error and its bifurcations were analysed and flip-type bifurcation was observed for CSLE. Experimental verification of the theoretical results was carried out.

  8. Cumulative neutrino background from quasar-driven outflows

    Energy Technology Data Exchange (ETDEWEB)

    Wang, Xiawei; Loeb, Abraham, E-mail: xiawei.wang@cfa.harvard.edu, E-mail: aloeb@cfa.harvard.edu [Department of Astronomy, Harvard University, 60 Garden Street, Cambridge, MA 02138 (United States)

    2016-12-01

    Quasar-driven outflows naturally account for the missing component of the extragalactic γ-ray background through neutral pion production in interactions between protons accelerated by the forward outflow shock and interstellar protons. We study the simultaneous neutrino emission by the same protons. We adopt outflow parameters that best fit the extragalactic γ-ray background data and derive a cumulative neutrino background of ∼ 10{sup −7} GeV cm{sup −2} s{sup −1} sr{sup −1} at neutrino energies E {sub ν} ∼> 10 TeV, which naturally explains the most recent IceCube data without tuning any free parameters. The link between the γ-ray and neutrino emission from quasar outflows can be used to constrain the high-energy physics of strong shocks at cosmological distances.

  9. Using Fuzzy Probability Weights in Cumulative Prospect Theory

    Directory of Open Access Journals (Sweden)

    Užga-Rebrovs Oļegs

    2016-12-01

    Full Text Available During the past years, a rapid growth has been seen in the descriptive approaches to decision choice. As opposed to normative expected utility theory, these approaches are based on the subjective perception of probabilities by the individuals, which takes place in real situations of risky choice. The modelling of this kind of perceptions is made on the basis of probability weighting functions. In cumulative prospect theory, which is the focus of this paper, decision prospect outcome weights are calculated using the obtained probability weights. If the value functions are constructed in the sets of positive and negative outcomes, then, based on the outcome value evaluations and outcome decision weights, generalised evaluations of prospect value are calculated, which are the basis for choosing an optimal prospect.

  10. Modelling the evolution and diversity of cumulative culture

    Science.gov (United States)

    Enquist, Magnus; Ghirlanda, Stefano; Eriksson, Kimmo

    2011-01-01

    Previous work on mathematical models of cultural evolution has mainly focused on the diffusion of simple cultural elements. However, a characteristic feature of human cultural evolution is the seemingly limitless appearance of new and increasingly complex cultural elements. Here, we develop a general modelling framework to study such cumulative processes, in which we assume that the appearance and disappearance of cultural elements are stochastic events that depend on the current state of culture. Five scenarios are explored: evolution of independent cultural elements, stepwise modification of elements, differentiation or combination of elements and systems of cultural elements. As one application of our framework, we study the evolution of cultural diversity (in time as well as between groups). PMID:21199845

  11. Optimal execution with price impact under Cumulative Prospect Theory

    Science.gov (United States)

    Zhao, Jingdong; Zhu, Hongliang; Li, Xindan

    2018-01-01

    Optimal execution of a stock (or portfolio) has been widely studied in academia and in practice over the past decade, and minimizing transaction costs is a critical point. However, few researchers consider the psychological factors for the traders. What are traders truly concerned with - buying low in the paper accounts or buying lower compared to others? We consider the optimal trading strategies in terms of the price impact and Cumulative Prospect Theory and identify some specific properties. Our analyses indicate that a large proportion of the execution volume is distributed at both ends of the transaction time. But the trader's optimal strategies may not be implemented at the same transaction size and speed in different market environments.

  12. Practical management of cumulative anthropogenic impacts with working marine examples

    DEFF Research Database (Denmark)

    Kyhn, Line Anker; Wright, Andrew J.

    2014-01-01

    for petroleum. Human disturbances, including the noise almost ubiquitously associated with human activity, are likely to increase the incidence, magnitude, and duration of adverse effects on marine life, including stress responses. Stress responses have the potential to induce fitness consequences...... on impact can be facilitated through implementation of regular application cycles for project authorization or improved programmatic and aggregated impact assessments that simultaneously consider multiple projects. Cross-company collaborations and a better incorporation of uncertainty into decision making...... could also help limit, if not reduce, cumulative impacts of multiple human activities. These simple management steps may also form the basis of a rudimentary form of marine spatial planning and could be used in support of future ecosystem-based management efforts....

  13. Dose rate constants for new dose quantities

    International Nuclear Information System (INIS)

    Tschurlovits, M.; Daverda, G.; Leitner, A.

    1992-01-01

    Conceptual changes and new quantities made is necessary to reassess dose rate quantities. Calculations of the dose rate constant were done for air kerma, ambient dose equivalent and directional dose equivalent. The number of radionuclides is more than 200. The threshold energy is selected as 20 keV for the dose equivalent constants. The dose rate constant for the photon equivalent dose as used mainly in German speaking countries as a temporary quantity is also included. (Author)

  14. Practical management of cumulative anthropogenic impacts with working marine examples.

    Science.gov (United States)

    Wright, Andrew J; Kyhn, Line A

    2015-04-01

    Human pressure on the environment is expanding and intensifying, especially in coastal and offshore areas. Major contributors to this are the current push for offshore renewable energy sources, which are thought of as environmentally friendly sources of power, as well as the continued demand for petroleum. Human disturbances, including the noise almost ubiquitously associated with human activity, are likely to increase the incidence, magnitude, and duration of adverse effects on marine life, including stress responses. Stress responses have the potential to induce fitness consequences for individuals, which add to more obvious directed takes (e.g., hunting or fishing) to increase the overall population-level impact. To meet the requirements of marine spatial planning and ecosystem-based management, many efforts are ongoing to quantify the cumulative impacts of all human actions on marine species or populations. Meanwhile, regulators face the challenge of managing these accumulating and interacting impacts with limited scientific guidance. We believe there is scientific support for capping the level of impact for (at a minimum) populations in decline or with unknown statuses. This cap on impact can be facilitated through implementation of regular application cycles for project authorization or improved programmatic and aggregated impact assessments that simultaneously consider multiple projects. Cross-company collaborations and a better incorporation of uncertainty into decision making could also help limit, if not reduce, cumulative impacts of multiple human activities. These simple management steps may also form the basis of a rudimentary form of marine spatial planning and could be used in support of future ecosystem-based management efforts. © 2014 Society for Conservation Biology.

  15. County-level cumulative environmental quality associated with cancer incidence.

    Science.gov (United States)

    Jagai, Jyotsna S; Messer, Lynne C; Rappazzo, Kristen M; Gray, Christine L; Grabich, Shannon C; Lobdell, Danelle T

    2017-08-01

    Individual environmental exposures are associated with cancer development; however, environmental exposures occur simultaneously. The Environmental Quality Index (EQI) is a county-level measure of cumulative environmental exposures that occur in 5 domains. The EQI was linked to county-level annual age-adjusted cancer incidence rates from the Surveillance, Epidemiology, and End Results (SEER) Program state cancer profiles. All-site cancer and the top 3 site-specific cancers for male and female subjects were considered. Incident rate differences (IRDs; annual rate difference per 100,000 persons) and 95% confidence intervals (CIs) were estimated using fixed-slope, random intercept multilevel linear regression models. Associations were assessed with domain-specific indices and analyses were stratified by rural/urban status. Comparing the highest quintile/poorest environmental quality with the lowest quintile/best environmental quality for overall EQI, all-site county-level cancer incidence rate was positively associated with poor environmental quality overall (IRD, 38.55; 95% CI, 29.57-47.53) and for male (IRD, 32.60; 95% CI, 16.28-48.91) and female (IRD, 30.34; 95% CI, 20.47-40.21) subjects, indicating a potential increase in cancer incidence with decreasing environmental quality. Rural/urban stratified models demonstrated positive associations comparing the highest with the lowest quintiles for all strata, except the thinly populated/rural stratum and in the metropolitan/urbanized stratum. Prostate and breast cancer demonstrated the strongest positive associations with poor environmental quality. We observed strong positive associations between the EQI and all-site cancer incidence rates, and associations differed by rural/urban status and environmental domain. Research focusing on single environmental exposures in cancer development may not address the broader environmental context in which cancers develop, and future research should address cumulative environmental

  16. Economic and policy implications of the cumulative carbon budget

    Science.gov (United States)

    Allen, M. R.; Otto, F. E. L.; Otto, A.; Hepburn, C.

    2014-12-01

    The importance of cumulative carbon emissions in determining long-term risks of climate change presents considerable challenges to policy makers. The traditional notion of "total CO2-equivalent emissions", which forms the backbone of agreements such as the Kyoto Protocol and the European Emissions Trading System, is fundamentally flawed. Measures to reduce short-lived climate pollutants benefit the current generation, while measures to reduce long-lived climate pollutants benefit future generations, so there is no sense in which they can ever be considered equivalent. Debates over the correct metric used to compute CO2-equivalence are thus entirely moot: both long-lived and short-lived emissions will need to be addressed if all generations are to be protected from dangerous climate change. As far as long-lived climate pollutants are concerned, the latest IPCC report highlights the overwhelming importance of carbon capture and storage in determining the cost of meeting the goal of limiting anthropogenic warming to two degrees. We will show that this importance arises directly from the cumulative carbon budget and the role of CCS as the technology of last resort before economic activity needs to be restricted to meet ambitious climate targets. It highlights the need to increase the rate of CCS deployment by orders of magnitude if the option of avoiding two degrees is to be retained. The difficulty of achieving this speed of deployment through conventional incentives and carbon-pricing mechanisms suggests a need for a much more direct mandatory approach. Despite their theoretical economic inefficiency, the success of recent regulatory measures in achieving greenhouse gas emissions reductions in jurisdictions such as the United States suggests an extension of the regulatory approach could be a more effective and politically acceptable means of achieving adequately rapid CCS deployment than conventional carbon taxes or cap-and-trade systems.

  17. Effects of low doses; Effet des faibles doses

    Energy Technology Data Exchange (ETDEWEB)

    Le Guen, B. [Electricite de France (EDF-LAM-SCAST), 93 - Saint-Denis (France)

    2001-07-01

    Actually, even though it is comfortable for the risk management, the hypothesis of the dose-effect relationship linearity is not confirmed for any model. In particular, in the area of low dose rate delivered by low let emitters. this hypothesis is debated at the light of recent observations, notably these ones relative to the mechanisms leading to genetic instability and induction eventuality of DNA repair. The problem of strong let emitters is still to solve. (N.C.)

  18. Antipsychotic dose equivalents and dose-years: a standardized method for comparing exposure to different drugs.

    Science.gov (United States)

    Andreasen, Nancy C; Pressler, Marcus; Nopoulos, Peg; Miller, Del; Ho, Beng-Choon

    2010-02-01

    A standardized quantitative method for comparing dosages of different drugs is a useful tool for designing clinical trials and for examining the effects of long-term medication side effects such as tardive dyskinesia. Such a method requires establishing dose equivalents. An expert consensus group has published charts of equivalent doses for various antipsychotic medications for first- and second-generation medications. These charts were used in this study. Regression was used to compare each drug in the experts' charts to chlorpromazine and haloperidol and to create formulas for each relationship. The formulas were solved for chlorpromazine 100 mg and haloperidol 2 mg to derive new chlorpromazine and haloperidol equivalents. The formulas were incorporated into our definition of dose-years such that 100 mg/day of chlorpromazine equivalent or 2 mg/day of haloperidol equivalent taken for 1 year is equal to one dose-year. All comparisons to chlorpromazine and haloperidol were highly linear with R(2) values greater than .9. A power transformation further improved linearity. By deriving a unique formula that converts doses to chlorpromazine or haloperidol equivalents, we can compare otherwise dissimilar drugs. These equivalents can be multiplied by the time an individual has been on a given dose to derive a cumulative value measured in dose-years in the form of (chlorpromazine equivalent in mg) x (time on dose measured in years). After each dose has been converted to dose-years, the results can be summed to provide a cumulative quantitative measure of lifetime exposure. Copyright 2010 Society of Biological Psychiatry. Published by Elsevier Inc. All rights reserved.

  19. Using the 60Co source to assess the dose received by risky organs during a cancer brain treatment

    International Nuclear Information System (INIS)

    Faik Ouahab, Z.; Jehouani, A.; Ghassoun, J.; Senhou, N.; Mouhssine, D.; Groetz, J.E.

    2010-01-01

    Summary of an investigation of exposures associated with brain cancer treatment for a child in order to determine the level of doses received by the different organs at risk during the treatment. Measurements have been performed at the vicinity of a cobalto therapy apparatus. Then, cumulative doses in each organ have been compared to admitted doses with respect to the organ

  20. Toward an ozone standard to protect vegetation based on effective dose: A review of deposition resistances and a possible metric

    Science.gov (United States)

    W. J. Massman

    2004-01-01

    Present air quality standards to protect vegetation from ozone are based on measured concentrations (i.e., exposure) rather than on plant uptake rates (or dose). Some familiar cumulative exposure-based indices include SUM06, AOT40, and W126. However, plant injury is more closely related to dose, or more appropriately to effective dose, than to exposure. This study...

  1. A Conceptual Framework for the Assessment of Cumulative Exposure to Air Pollution at a Fine Spatial Scale

    Directory of Open Access Journals (Sweden)

    Kihal-Talantikite Wahida

    2016-03-01

    Full Text Available Many epidemiological studies examining long-term health effects of exposure to air pollutants have characterized exposure by the outdoor air concentrations at sites that may be distant to subjects’ residences at different points in time. The temporal and spatial mobility of subjects and the spatial scale of exposure assessment could thus lead to misclassification in the cumulative exposure estimation. This paper attempts to fill the gap regarding cumulative exposure assessment to air pollution at a fine spatial scale in epidemiological studies investigating long-term health effects. We propose a conceptual framework showing how major difficulties in cumulative long-term exposure assessment could be surmounted. We then illustrate this conceptual model on the case of exposure to NO2 following two steps: (i retrospective reconstitution of NO2 concentrations at a fine spatial scale; and (ii a novel approach to assigning the time-relevant exposure estimates at the census block level, using all available data on residential mobility throughout a 10- to 20-year period prior to that for which the health events are to be detected. Our conceptual framework is both flexible and convenient for the needs of different epidemiological study designs.

  2. A Conceptual Framework for the Assessment of Cumulative Exposure to Air Pollution at a Fine Spatial Scale

    Science.gov (United States)

    Wahida, Kihal-Talantikite; Padilla, Cindy M.; Denis, Zmirou-Navier; Olivier, Blanchard; Géraldine, Le Nir; Philippe, Quenel; Séverine, Deguen

    2016-01-01

    Many epidemiological studies examining long-term health effects of exposure to air pollutants have characterized exposure by the outdoor air concentrations at sites that may be distant to subjects’ residences at different points in time. The temporal and spatial mobility of subjects and the spatial scale of exposure assessment could thus lead to misclassification in the cumulative exposure estimation. This paper attempts to fill the gap regarding cumulative exposure assessment to air pollution at a fine spatial scale in epidemiological studies investigating long-term health effects. We propose a conceptual framework showing how major difficulties in cumulative long-term exposure assessment could be surmounted. We then illustrate this conceptual model on the case of exposure to NO2 following two steps: (i) retrospective reconstitution of NO2 concentrations at a fine spatial scale; and (ii) a novel approach to assigning the time-relevant exposure estimates at the census block level, using all available data on residential mobility throughout a 10- to 20-year period prior to that for which the health events are to be detected. Our conceptual framework is both flexible and convenient for the needs of different epidemiological study designs. PMID:26999170

  3. Tin- and Lead-Based Perovskite Solar Cells under Scrutiny: An Environmental Perspective

    DEFF Research Database (Denmark)

    Serrano-Luján, Lucía; Espinosa Martinez, Nieves; Larsen-Olsen, Thue Trofod

    2015-01-01

    The effect of substituting lead with tin in perovskite-based solar cells (PSCs) has shows that lead is preferred over tin by a lower cumulative energy demand. The results, which also include end-of-life management, show that a recycling scenario that carefully handles emission of lead enables use...

  4. Soil is an important pathway of human lead exposure.

    OpenAIRE

    Mielke, H W; Reagan, P L

    1998-01-01

    This review shows the equal or greater importance of leaded gasoline-contaminated dust compared to lead-based paint to the child lead problem, and that soil lead, resulting from leaded gasoline and pulverized lead-based paint, is at least or more important than lead-based paint (intact and not pulverized) as a pathway of human lead exposure. Because lead-based paint is a high-dose source, the biologically relevant dosage is similar to lead in soil. Both lead-based paint and soil lead are asso...

  5. Patient exposure: description of cumulative irradiation of patients treated in interventional cardiology; Exposition des patients: description de l'irradiation cumulee des patients traites en cardiologie interventionnelle

    Energy Technology Data Exchange (ETDEWEB)

    Odile Bernier, M.O. [Institut de Radioprotection et de Surete Nucleaire, Laboratoire d ' Epidemiologie, 92 - Fontenay aux Roses (France)

    2009-07-01

    Despite its clinical benefits, interventional cardiology induces cumulative exposure to ionizing radiation and may entail an important irradiation of the patient at the cutaneous level as well as for organs at the vicinity of the heart. The author briefly reports a study performed on a sample of 1591 patients who have been submitted to at least one corono-graphy or one angioplasty during 2005. Based on clinical characteristics and dose-area-product measurements, the doses received by lung, oesophagus, bone medulla and breast have been computed

  6. The cumulative burden of surviving childhood cancer: an initial report from the St Jude Lifetime Cohort Study (SJLIFE).

    Science.gov (United States)

    Bhakta, Nickhill; Liu, Qi; Ness, Kirsten K; Baassiri, Malek; Eissa, Hesham; Yeo, Frederick; Chemaitilly, Wassim; Ehrhardt, Matthew J; Bass, Johnnie; Bishop, Michael W; Shelton, Kyla; Lu, Lu; Huang, Sujuan; Li, Zhenghong; Caron, Eric; Lanctot, Jennifer; Howell, Carrie; Folse, Timothy; Joshi, Vijaya; Green, Daniel M; Mulrooney, Daniel A; Armstrong, Gregory T; Krull, Kevin R; Brinkman, Tara M; Khan, Raja B; Srivastava, Deo K; Hudson, Melissa M; Yasui, Yutaka; Robison, Leslie L

    2017-12-09

    ·9-2·7, pgrade 1-5 CHCs at age 50 years was highest in survivors of CNS malignancies (24·2 [95% CI 20·9-27·5]) and lowest in survivors of germ cell tumours (14·0 [11·5-16·6]). Multivariable analyses showed that older age at diagnosis, treatment era, and higher doses of brain and chest radiation are significantly associated with a greater cumulative burden and severity of CHCs. The burden of CHCs in survivors of childhood cancer is substantial and highly variable. Our assessment of total cumulative burden in survivors of paediatric cancer, with detailed characterisation of long-term CHCs, provide data to better inform future clinical guidelines, research investigations, and health services planning for this vulnerable, medically complex population. The US National Cancer Institute, St Baldrick's Foundation, and the American Lebanese Syrian Associated Charities. Copyright © 2017 Elsevier Ltd. All rights reserved.

  7. Radiation doses from residual radioactivity

    International Nuclear Information System (INIS)

    Okajima, Shunzo; Fujita, Shoichiro; Harley, John H.

    1987-01-01

    requires knowing the location of the person to within about 200 m from the time of the explosion to a few weeks afterwards. This is an effort that might be comparable to the present shielding study for survivors. The sizes of the four exposed groups are relatively small; however, the number has been estimated only for those exposed to fallout in the Nishiyama district of Nagasaki. Okajima listed the population of Nishiyama as about 600 at the time of the bomb. No figures are available for the other three groups. The individual exposures from residual radiation may not be significant compared with the direct radiation at the time of the bomb. On the other hand, individuals with potential exposure from these sources are dubious candidates for inclusion in a cohort that was presumably not exposed. For comparison with organ doses estimated in other parts of this program, the exposure estimates are converted to absorbed dose in tissue. The first conversion of exposure to absorbed dose in air uses the factor rad in air 0.87 x exposure in R. UNSCEAR uses an average combined factor of 0.7 to convert absorbed dose in air to absorbed dose in tissue for the whole body. This factor accounts for the change in material (air to tissue) and for backscatter and the shielding afforded by other tissues of the body. No allowance for shielding by buildings has been included here. The cumulative fallout exposures given above become absorbed doses in tissue of 12 to 24 rad for Nagasaki and 0.6 to 2 rad for Hiroshima. The cumulative exposures from induced radioactivity become absorbed doses in tissue of 18 to 24 rad for Nagasaki and about 50 rad for Hiroshima. (author)

  8. Melatonin reduces lead levels in blood, brain and bone and increases lead excretion in rats subjected to subacute lead treatment.

    Science.gov (United States)

    Hernández-Plata, Everardo; Quiroz-Compeán, Fátima; Ramírez-Garcia, Gonzalo; Barrientos, Eunice Yáñez; Rodríguez-Morales, Nadia M; Flores, Alberto; Wrobel, Katarzina; Wrobel, Kazimierz; Méndez, Isabel; Díaz-Muñoz, Mauricio; Robles, Juvencio; Martínez-Alfaro, Minerva

    2015-03-04

    Melatonin, a hormone known for its effects on free radical scavenging and antioxidant activity, can reduce lead toxicity in vivo and in vitro.We examined the effects of melatonin on lead bio-distribution. Rats were intraperitoneally injected with lead acetate (10, 15 or 20mg/kg/day) with or without melatonin (10mg/kg/day) daily for 10 days. In rats intoxicated with the highest lead doses, those treated with melatonin had lower lead levels in blood and higher levels in urine and feces than those treated with lead alone, suggesting that melatonin increases lead excretion. To explore the mechanism underlying this effect, we first assessed whether lead/melatonin complexes were formed directly. Electronic density functional (DFT) calculations showed that a lead/melatonin complex is energetically feasible; however, UV spectroscopy and NMR analysis showed no evidence of such complexes. Next, we examined the liver mRNA levels of metallothioneins (MT) 1 and 2. Melatonin cotreatment increased the MT2 mRNA expression in the liver of rats that received the highest doses of lead. The potential effects of MTs on the tissue distribution and excretion of lead are not well understood. This is the first report to suggest that melatonin directly affects lead levels in organisms exposed to subacute lead intoxication. Copyright © 2015 Elsevier Ireland Ltd. All rights reserved.

  9. Patient doses in interventional cardiology procedures

    International Nuclear Information System (INIS)

    Domienik, J.; Papierz, S.; Jankowski, J.; Peruga, J.Z.

    2008-01-01

    In most countries of European Union legislation requires the determination of the total skin dose to patient resulting from interventional procedures to assess the risk of deterministic effect. To this end, various dose indicators like dose area product (DAP), cumulative dose (CD) and entrance dose at the patient plane (EFD) are used in clinical practice. The study aims at relating those dose indicators with doses ascribe to the most irradiated areas of the patient skin usually expressed in terms of local maximal skin dose (MSD). For the study the local MSD and related to their areas are investigated and compared for coronary angiography CA and intervention (PCI). Two methods implying radiographic films Kodak EDR2 and matrixes of thermoluminescent dosimeters (TLDs) are applied for direct measurements of dose distribution for selected procedures. Both methods are compared. Additionally, for patient dosimetry the following data: MSD, CD, EFD, fluoroscopy time (FT), number of acquired images, total DAP, fluoro-DAP and record-DAP were collected for randomly selected procedure. The statistical quantities like: median, 3 rd quartile, mean and standard deviation for all dosimetric parameters are determined. Preliminary study showed that the values of data collected for coronary procedures are in the ranges 0,7 - 27,3 min for fluoroscopy time, 50 - 350 Gy cm 2 for total DAP, 300 - 2000 mGy for CD, 140 - 2000 mGy for EFD and 100 - 1500 mGy for local maximal skin dose. For interventions the ranges are, accordingly 3,0 - 43,6 min , 25 - 450 Gy cm 2 , 270 - 6600 mGy, 80 - 2600 mGy and 80 - 1500 mGy. As a result of the study the correlations between dose indicators and local MSD are analyzed. The concentration of dose on irradiated films are going to be investigated in some detail as well. (author)

  10. Direct dose mapping versus energy/mass transfer mapping for 4D dose accumulation: fundamental differences and dosimetric consequences.

    Science.gov (United States)

    Li, Haisen S; Zhong, Hualiang; Kim, Jinkoo; Glide-Hurst, Carri; Gulam, Misbah; Nurushev, Teamour S; Chetty, Indrin J

    2014-01-06

    The direct dose mapping (DDM) and energy/mass transfer (EMT) mapping are two essential algorithms for accumulating the dose from different anatomic phases to the reference phase when there is organ motion or tumor/tissue deformation during the delivery of radiation therapy. DDM is based on interpolation of the dose values from one dose grid to another and thus lacks rigor in defining the dose when there are multiple dose values mapped to one dose voxel in the reference phase due to tissue/tumor deformation. On the other hand, EMT counts the total energy and mass transferred to each voxel in the reference phase and calculates the dose by dividing the energy by mass. Therefore it is based on fundamentally sound physics principles. In this study, we implemented the two algorithms and integrated them within the Eclipse treatment planning system. We then compared the clinical dosimetric difference between the two algorithms for ten lung cancer patients receiving stereotactic radiosurgery treatment, by accumulating the delivered dose to the end-of-exhale (EE) phase. Specifically, the respiratory period was divided into ten phases and the dose to each phase was calculated and mapped to the EE phase and then accumulated. The displacement vector field generated by Demons-based registration of the source and reference images was used to transfer the dose and energy. The DDM and EMT algorithms produced noticeably different cumulative dose in the regions with sharp mass density variations and/or high dose gradients. For the planning target volume (PTV) and internal target volume (ITV) minimum dose, the difference was up to 11% and 4% respectively. This suggests that DDM might not be adequate for obtaining an accurate dose distribution of the cumulative plan, instead, EMT should be considered.

  11. Radiation dose during angiographic procedures

    International Nuclear Information System (INIS)

    Lavoie, Ch.; Rasuli, P.

    2001-01-01

    The use of angiographic procedures is becoming more prevalent as new techniques and equipment are developed. There have been concerns in the scientific community about the level of radiation doses received by patients, and indirectly by staff, during some of these radiological procedures. The purpose of this study was to assess the level of radiation dose from angiographic procedures to patient at the Ottawa Hospital, General Campus. Radiation dose measurements, using Thermo-Luminescent Dosimeters (TLDs), were performed on more than 100 patients on various procedures. The results show that while the patient dose from the great majority of angiographic procedures is less than 2 Gy, a significant number of procedures, especially interventional procedures may have doses greater than 2 Gy and may lead to deterministic effects. (author)