WorldWideScience

Sample records for cumulative catheter survival

  1. FACTORS AND COMPLICATIONS AFFECTING CATHETER AND TECHNIQUE SURVIVAL WITH PERMANENT SINGLE-LUMEN DIALYSIS CATHETERS

    NARCIS (Netherlands)

    DEMEESTER, J; VANHOLDER, R; DEROOSE, J; RINGOIR, S

    1994-01-01

    This long-term study on the outcome of permanent silicone single-lumen dialysis catheters consisted of 43 surgically inserted catheters in 33 patients. All catheters were attached to a pressure-pressure single-cannula dialysis system. Technique and catheter survival were 80 and 59% at 1 year, and 63

  2. The seven-year cumulative survival rate of Osstem implants

    Science.gov (United States)

    Kim, Young-Kyun; Kim, Bum-Su; Yun, Pil-Young; Mun, Sang-Un; Yi, Yang-Jin; Jeong, Kyung-In

    2014-01-01

    Objectives This study was performed to analyze the cumulative survival rate of Osstem implants (Osstem Implant Co., Ltd.) over a seven-year period. Materials and Methods A total of 105 patients who had 467 Osstem implants that were placed at the Section of Dentistry, Seoul National University Bundang Hospital (Seongnam, Korea) from June 2003 through December 2005 were analyzed. The life table method and a cross-tubulation analysis, log rank test were used to evaluate the survival curve and the influence that the prognostic factors. The prognostic factors, i.e., age and gender of patients, diameter and length, type of implants, bone graft history and loading time were determined with a Cox proportional hazard model based on logistic regression analysis. Results The seven-year cumulative survival rate of Osstem implants was 95.37%. The Cox proportional hazard model revealed that the following factors had a significant influence on survival rate; increased diameter, reduced prosthetic loading period and performance of bone grafting. Conclusion The osstem implants showed satisfactory results over the seven-year study period. PMID:24868503

  3. The Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) trial.

    Science.gov (United States)

    Eichhorn, Eric J; Bristow, Michael R

    2001-01-01

    Previous trials (Metoprolol CR/XL Randomised Intervention Trial in Congestive Heart Failure [MERIT-HF], Cardiac Insufficiency Bisoprolol Study [CIBIS] II) have demonstrated a mortality benefit of beta-adrenergic blockade in patients with mild to moderate heart failure. The recent Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) trial has extended these results to a more advanced patient population. This trial did not, however, include patients who could not reach compensation, patients with far advanced heart failure symptoms, or a significant number of black patients. Future studies of beta-blockade may focus on these patients or patients with asymptomatic left ventricular dysfunction.

  4. The Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS trial

    Directory of Open Access Journals (Sweden)

    Bristow Michael R

    2001-02-01

    Full Text Available Abstract Previous trials (Metoprolol CR/XL Randomised Intervention Trial in Congestive Heart Failure [MERIT-HF], Cardiac Insufficiency Bisoprolol Study [CIBIS] II have demonstrated a mortality benefit of β-adrenergic blockade in patients with mild to moderate heart failure. The recent Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS trial has extended these results to a more advanced patient population. This trial did not, however, include patients who could not reach compensation, patients with far advanced heart failure symptoms, or a significant number of black patients. Future studies of β-blockade may focus on these patients or patients with asymptomatic left ventricular dysfunction.

  5. Ventricular catheter entry site and not catheter tip location predicts shunt survival: a secondary analysis of 3 large pediatric hydrocephalus studies.

    Science.gov (United States)

    Whitehead, William E; Riva-Cambrin, Jay; Kulkarni, Abhaya V; Wellons, John C; Rozzelle, Curtis J; Tamber, Mandeep S; Limbrick, David D; Browd, Samuel R; Naftel, Robert P; Shannon, Chevis N; Simon, Tamara D; Holubkov, Richard; Illner, Anna; Cochrane, D Douglas; Drake, James M; Luerssen, Thomas G; Oakes, W Jerry; Kestle, John R W

    2017-02-01

    OBJECTIVE Accurate placement of ventricular catheters may result in prolonged shunt survival, but the best target for the hole-bearing segment of the catheter has not been rigorously defined. The goal of the study was to define a target within the ventricle with the lowest risk of shunt failure. METHODS Five catheter placement variables (ventricular catheter tip location, ventricular catheter tip environment, relationship to choroid plexus, catheter tip holes within ventricle, and crosses midline) were defined, assessed for interobserver agreement, and evaluated for their effect on shunt survival in univariate and multivariate analyses. De-identified subjects from the Shunt Design Trial, the Endoscopic Shunt Insertion Trial, and a Hydrocephalus Clinical Research Network study on ultrasound-guided catheter placement were combined (n = 858 subjects, all first-time shunt insertions, all patients 0.60). In the univariate survival analysis, however, only ventricular catheter tip location was useful in distinguishing a target within the ventricle with a survival advantage (frontal horn; log-rank, p = 0.0015). None of the other catheter placement variables yielded a significant survival advantage unless they were compared with catheter tips completely not in the ventricle. Cox regression analysis was performed, examining ventricular catheter tip location with age, etiology, surgeon, decade of surgery, and catheter entry site (anterior vs posterior). Only age (p < 0.001) and entry site (p = 0.005) were associated with shunt survival; ventricular catheter tip location was not (p = 0.37). Anterior entry site lowered the risk of shunt failure compared with posterior entry site by approximately one-third (HR 0.65, 95% CI 0.51-0.83). CONCLUSIONS This analysis failed to identify an ideal target within the ventricle for the ventricular catheter tip. Unexpectedly, the choice of an anterior versus posterior catheter entry site was more important in determining shunt survival than

  6. Laparoscopic Placement of Peritoneal Dialysis Catheters in CAPD Patients: Complications and Survival

    Directory of Open Access Journals (Sweden)

    A Roueentan

    2008-06-01

    Full Text Available Background: Laparoscopic techniques for the placement of peritoneal dialysis catheters are becoming increasingly popular. Recently, with the improvements in laparoscopic surgery, various methods for the insertion of peritoneal dialysis catheters have been reported, indicating that the laparoscopic insertion is preferred over the open and percutaneous techniques. The aim of this study was to introduce and assess a simplified laparoscopic method for the insertion of peritoneal dialysis catheters in continuous ambulatory peritoneal dialysis (CAPD patients.Methods: We enrolled 79 consecutive end-stage renal patients (46 men and 33 women with a mean age of 50 years (range: 19-83 years in this study. During the surgery, a 5-mm trocar was placed in the left upper quadrant for the optics and another 5-mm trocar was placed to the left of the umbilicus. Using the second trocar, a tunnel was formed 2 cm left of the umbilical plane for the insertion of a Tenckhoff catheter. Under direct vision, the catheter was advanced into the abdomen. The catheter was tested for patency. Catheters of all subjects were capped for two weeks before dialysis initiation.Results: The mean duration of the operation was 15 minutes. Ten patients died during the follow-up period, all due to other medical problems, and six patients underwent renal transplantation; however, no deaths or complications were observed during surgery. Early onset complications were seen in 12 patients (15.1%. The most frequent late-onset medical and mechanical complications were peritonitis (6.3% and hernia (3.7%. During a follow-up period of four years, removal of the catheter was required in two patients as a result of peritonitis.Conclusion: We obtained a low complication rate and a high catheter survival rate with this laparoscopic insertion of the Tenckhoff catheter. We believe future experience will encourage the use of this safe, simple and quick procedure.

  7. SURVIVAL OF CONTINUOUS AMBULATORY PERITONEAL DIALYSIS CATHETERS: AN EVALUATION OF SURGICAL AND NON-SURGICAL FACTORS (SINGLE CENTER STUDY

    Directory of Open Access Journals (Sweden)

    A. Keshvari

    2006-06-01

    Full Text Available Peritoneal dialysis is an established form of renal replacement therapy used in many patients with end-stage renal disease. The key to a successful chronic peritoneal dialysis is a permanent and safe access to the peritoneal cavity. This study was conducted in order to evaluate the catheter survival and its related factors in Imam Khomeini Hospital. A total of 80 catheters were inserted into 69 patients (52 men and 28 women with end-stage chronic renal failure during a period of 84 months. Retrospectively the correlation between catheter survival (overall and event free with demographic factors (sex and age, surgical factors (surgeons and surgical methods, nephrologic factors (the causes of peritoneal dialysis selection and the history of hemodialysis and peritonitis factors (the history and number of peritonitis has been evaluated. The mean age of the patients was 48.35 years (16 to 79 years. The overall survival of catheters or the probability of having a functioning catheter after one, two and three years was 53%, 41%, 22%, respectively. The event free survival of the catheter or the probability of having a functioning catheter without any problems after one year was 14%. It has been found out that among all factors in this study only history of hemodialysis had statistically significant effect on the overall survival of continuous ambulatory peritoneal dialysis catheter (P = 0.04. It seems that the overall survival of catheters is better when CAPD is started before any other attempts for hemodialysis.

  8. Survival and complications of peritoneal dialysis catheters: introducing a laparoscopic method under local anesthesia

    Directory of Open Access Journals (Sweden)

    Chaman R

    2008-10-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Chronic peritoneal dialysis is a safe method for the treatment of end-stage renal failure. Worldwide, patients on chronic peritoneal dialysis constititute approximately 15% of the total number of patients on dialysis. In Iran, very few people have access to chronic peritoneal dialysis, which is targeted by the Ministry of Health. This lack of access is primarily due to the high occurrence of mechanical complications. Improving catheterization procedures is an important way to extend the use of peritoneal dialysis in Iran. Thus, a prospective study was implemented to evaluate the outcome of a new laparoscopic technique for the insertion of peritoneal dialysis catheters under local anesthesia."n"n Methods: A total of 115 catheters (two-cuff, swan-necked, coiled were inserted into the peritoneal cavity of 109 patients with end-stage chronic renal failure during a 16-month period. The method of insertion was a two-port laparoscopic technique with local anesthesia and sedation. All patients were followed for 12 to 28 months. We prospectively evaluated mechanical and infectious complications and survival rates of the catheters."n"n Results: The average age of the patients was 51

  9. A study of outcome and complications associated with temporary hemodialysis catheters in a Nigerian dialysis unit.

    Science.gov (United States)

    Amira, Christiana Oluwatoyin; Bello, Babawale Taslim; Braimoh, Rotimi Williams

    2016-05-01

    Hemodialysis (HD) catheters are commonly used as temporary vascular access in patients with kidney failure who require immediate HD. The use of these catheters is limited by complications such as infections, thrombosis resulting in poor blood flow. We studied the complications and outcomes of nontunneled catheters used for vascular access in our dialysis unit. The records of all patients, with renal failure who were dialyzed over a two-year period and had a double lumen nontunneled catheter inserted, were retrieved. Catheter insertion was carried out under ultrasound guidance using the modified Seldinger technique. The demographic data of patients, etiology of chronic kidney disease, and complications and outcomes of these catheters were noted. Fifty-four patients with mean age 43.7 ± 15.8 years had 69 catheters inserted for a cumulative total of 4047 catheter-days. The mean catheter patency was 36.4 ± 37.2 days (range: 1-173 days). Thrombosis occluding the catheters was the most common complication and occurred in 58% of catheters leading to catheter malfunction, followed by infections in18.8% of catheters. During follow-up, 30 (43.5%) catheters were removed, 14 (20.3%) due to catheter malfunction, eight (11.6%) due to infection, five (7.2%) elective removal, and three (4.3%) due to damage. Thrombotic occlusion of catheters was a major limiting factor to the survival of HD catheters. Improvement in catheter patency can be achieved with more potent lock solutions.

  10. Factors affecting survival in pediatric cardiac tamponade caused by central venous catheters.

    Science.gov (United States)

    Kayashima, Kenji

    2015-12-01

    Pediatric central venous catheter (CVC) placement is useful but associated with complications such as cardiac tamponade. We aimed to identify risk factors for death in cardiac tamponade. Published articles on pediatric CVC-associated cardiac tamponade were obtained by searching PubMed and Google and retrospectively reviewed to analyze risk factors for death. Factors examined for their effect on mortality risk included patient age, weight, CVC size, days from CVC insertion to tamponade occurrence, substances administered, insertion site, treatment, CVC material, and initial CVC tip position. Of 110 patients reported in 62 articles, 69 survived and 41 died. Among survivors, 55 of 69 patients were treated; among deaths, only 7 of 38 (OR 537.9, 95% CI 29.3-9,877, p tamponade survival. Past studies have mainly discussed how to avoid pediatric cardiac tamponade; by contrast, the present study focused on how to avoid deaths. The findings of this review suggest that cardiac tamponade survival is better when tamponade is detected early and treated promptly and might be affected by initial CVC tip position.

  11. Complications, effects on dialysis dose, and survival of tunneled femoral dialysis catheters in acute renal failure.

    Science.gov (United States)

    Klouche, Kada; Amigues, Laurent; Deleuze, Sebastien; Beraud, Jean-Jacques; Canaud, Bernard

    2007-01-01

    Availability of a functional vascular access is a mandatory prerequisite for extracorporeal renal replacement therapy in patients with acute renal failure. The femoral site of insertion commonly is chosen because it is an easy and convenient access. However, an array of complications may substantially alter the quality of treatment, and it appears that catheter-related morbidity and dysfunction are more frequent with the femoral than internal jugular site. This study is designed to evaluate the potential benefits of using soft silicone tunneled catheters ((ST)Caths) at the femoral site. Thirty patients with acute renal failure treated by intermittent hemodialysis (IHD) and/or continuous venovenous hemodiafiltration (CVVHDF) were assigned to either twin (ST)Caths or twin polyurethane nontunneled femoral catheters. Time necessary for catheter insertion, catheter-related complications, and catheter lifespan were monitored. Catheter performance during IHD and the effect of catheter type on dialysis dose were evaluated. The time necessary for (ST)Cath insertion was significantly longer. The incidence of vein thrombosis and catheter-related infection was lower, and the ratio of venous return pressure to catheter blood flow was better with an (ST)Cath. Recirculation rates were similar for both types of catheters. Whether treated by using IHD or CVVHDF, patients with an (ST)Cath benefited from a greater delivered dialysis dose. Multivariate analysis confirmed that (ST)Cath use was a determinant factor to optimize dialysis dose delivery. (ST)Cath patency was significantly longer. In patients with acute renal failure, use of an (ST)Cath minimizes catheter-related morbidity and improves dialysis efficiency compared with conventional femoral catheters.

  12. Instrumental variables estimation of exposure effects on a time-to-event response using structural cumulative survival models

    DEFF Research Database (Denmark)

    Martinussen, T.; Vansteelandt, S.; Tchetgen, E. J. Tchetgen;

    2016-01-01

    of complications due to censoring and survivorship bias. In this paper, we make a novel proposal under a class of structural cumulative survival models which parameterize time-varying effects of a point exposure directly on the scale of the survival function; these models are essentially equivalent with a semi......-parametric variant of the instrumental variables additive hazards model. We propose a class of recursive instrumental variable estimators for these exposure effects, and derive their large sample properties along with inferential tools. We examine the performance of the proposed method in simulation studies...

  13. Meta-analysis for aggregated survival data with competing risks: a parametric approach using cumulative incidence functions.

    Science.gov (United States)

    Bonofiglio, Federico; Beyersmann, Jan; Schumacher, Martin; Koller, Michael; Schwarzer, Guido

    2016-09-01

    Meta-analysis of a survival endpoint is typically based on the pooling of hazard ratios (HRs). If competing risks occur, the HRs may lose translation into changes of survival probability. The cumulative incidence functions (CIFs), the expected proportion of cause-specific events over time, re-connect the cause-specific hazards (CSHs) to the probability of each event type. We use CIF ratios to measure treatment effect on each event type. To retrieve information on aggregated, typically poorly reported, competing risks data, we assume constant CSHs. Next, we develop methods to pool CIF ratios across studies. The procedure computes pooled HRs alongside and checks the influence of follow-up time on the analysis. We apply the method to a medical example, showing that follow-up duration is relevant both for pooled cause-specific HRs and CIF ratios. Moreover, if all-cause hazard and follow-up time are large enough, CIF ratios may reveal additional information about the effect of treatment on the cumulative probability of each event type. Finally, to improve the usefulness of such analysis, better reporting of competing risks data is needed. Copyright © 2015 John Wiley & Sons, Ltd.

  14. ADSORPTION OF CIPROFLOXACIN TO URINARY CATHETERS AND EFFECT ON SUBSEQUENT BACTERIAL ADHESION AND SURVIVAL

    NARCIS (Netherlands)

    REID, G; TIESZER, C; FOERCH, R; BUSSCHER, HJ; KHOURY, AE; BRUCE, AW

    1993-01-01

    The preincubation of urinary catheter material with minimum inhibitory and sub-inhibitory concentrations of ciprofloxacin caused a significant reduction in the adhesion of viable uropathogenic Escherichia coli subsequently exposed to the surfaces for periods of 1, 12, 24 and 48 h. In addition, the

  15. ADSORPTION OF CIPROFLOXACIN TO URINARY CATHETERS AND EFFECT ON SUBSEQUENT BACTERIAL ADHESION AND SURVIVAL

    NARCIS (Netherlands)

    REID, G; TIESZER, C; FOERCH, R; BUSSCHER, HJ; KHOURY, AE; BRUCE, AW

    1993-01-01

    The preincubation of urinary catheter material with minimum inhibitory and sub-inhibitory concentrations of ciprofloxacin caused a significant reduction in the adhesion of viable uropathogenic Escherichia coli subsequently exposed to the surfaces for periods of 1, 12, 24 and 48 h. In addition, the o

  16. A study of outcome and complications associated with temporary hemodialysis catheters in a Nigerian dialysis unit

    Directory of Open Access Journals (Sweden)

    Christiana Oluwatoyin Amira

    2016-01-01

    Full Text Available Hemodialysis (HD catheters are commonly used as temporary vascular access in patients with kidney failure who require immediate HD. The use of these catheters is limited by complications such as infections, thrombosis resulting in poor blood flow. We studied the complications and outcomes of nontunneled catheters used for vascular access in our dialysis unit. The records of all patients, with renal failure who were dialyzed over a two-year period and had a double lumen nontunneled catheter inserted, were retrieved. Catheter insertion was carried out under ultrasound guidance using the modified Seldinger technique. The demographic data of patients, etiology of chronic kidney disease, and complications and outcomes of these catheters were noted. Fifty-four patients with mean age 43.7 ± 15.8 years had 69 catheters inserted for a cumulative total of 4047 catheter-days. The mean catheter patency was 36.4 ± 37.2 days (range: 1-173 days. Thrombosis occluding the catheters was the most common complication and occurred in 58% of catheters leading to catheter malfunction, followed by infections in18.8% of catheters. During follow-up, 30 (43.5% catheters were removed, 14 (20.3% due to catheter malfunction, eight (11.6% due to infection, five (7.2% elective removal, and three (4.3% due to damage. Thrombotic occlusion of catheters was a major limiting factor to the survival of HD catheters. Improvement in catheter patency can be achieved with more potent lock solutions.

  17. Patients started on hemodialysis with tunneled dialysis catheter have similar survival after arteriovenous fistula and arteriovenous graft creation.

    Science.gov (United States)

    Yuo, Theodore H; Chaer, Rabih A; Dillavou, Ellen D; Leers, Steven A; Makaroun, Michel S

    2015-12-01

    Current guidelines suggest that arteriovenous fistula (AVF) is associated with survival advantage over arteriovenous graft (AVG). However, AVFs often require months to become functional, increasing tunneled dialysis catheter (TDC) use, which can erode the benefit of an AVF. We sought to compare survival in patients with end-stage renal disease after creation of an AVF or AVG in patients starting hemodialysis (HD) with a TDC and to identify patient populations that may benefit from preferential use of AVG over AVF. Using U.S. Renal Data System databases, we identified incident HD patients in 2005 through 2008 and observed them through 2008. Initial access type and clinical variables including albumin levels were assessed using U.S. Renal Data System data collection forms. Attempts at AVF and AVG creation in patients who started HD through a TDC were identified by Current Procedural Terminology codes. We accounted for the effect of changes in access type by truncating follow-up when an additional AVF or AVG was performed. Survival curves were then constructed, and log-rank tests were used for pairwise survival comparisons, stratified by age. Multivariate analysis was performed with Cox proportional hazards regressions; variables were chosen using stepwise elimination. An interaction of access type and albumin level was detected, and Cox models using differing thresholds for albumin level were constructed. The primary outcome was survival. Among the 138,245 patients who started with a TDC and had complete records amenable for analysis, 22.8% underwent AVF creation (mean age ± standard deviation, 68.9 ± 12.5 years; 27.8% mortality at 1 year) and 7.6% underwent AVG placement (70.2 ± 12.0 years; 28.2% mortality) within 3 months of HD initiation; 69.6% remained with a TDC (63.2 ± 15.4 years; 33.8% mortality). In adjusted Cox proportional hazards regression, AVF creation is equivalent to AVG placement in terms of survival (hazard ratio [HR], 0.98; 95% confidence

  18. The effects of increased constant incubation temperature and cumulative acute heat shock exposures on morphology and survival of Lake Whitefish (Coregonus clupeaformis) embryos.

    Science.gov (United States)

    Lee, Abigail H; Eme, John; Mueller, Casey A; Manzon, Richard G; Somers, Christopher M; Boreham, Douglas R; Wilson, Joanna Y

    2016-04-01

    Increasing incubation temperatures, caused by global climate change or thermal effluent from industrial processes, may influence embryonic development of fish. This study investigates the cumulative effects of increased incubation temperature and repeated heat shocks on developing Lake Whitefish (Coregonus clupeaformis) embryos. We studied the effects of three constant incubation temperatures (2°C, 5°C or 8°C water) and weekly, 1-h heat shocks (+3°C) on hatching time, survival and morphology of embryos, as these endpoints may be particularly susceptible to temperature changes. The constant temperatures represent the predicted magnitude of elevated water temperatures from climate change and industrial thermal plumes. Time to the pre-hatch stage decreased as constant incubation temperature increased (148d at 2°C, 92d at 5°C, 50d at 8°C), but weekly heat shocks did not affect time to hatch. Mean survival rates and embryo morphometrics were compared at specific developmental time-points (blastopore, eyed, fin flutter and pre-hatch) across all treatments. Constant incubation temperatures or +3°C heat-shock exposures did not significantly alter cumulative survival percentage (~50% cumulative survival to pre-hatch stage). Constant warm incubation temperatures did result in differences in morphology in pre-hatch stage embryos. 8°C and 5°C embryos were significantly smaller and had larger yolks than 2°C embryos, but heat-shocked embryos did not differ from their respective constant temperature treatment groups. Elevated incubation temperatures may adversely alter Lake Whitefish embryo size at hatch, but weekly 1-h heat shocks did not affect size or survival at hatch. These results suggest that intermittent bouts of warm water effluent (e.g., variable industrial emissions) are less likely to negatively affect Lake Whitefish embryonic development than warmer constant incubation temperatures that may occur due to climate change.

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... use of a catheter makes it possible to combine diagnosis and treatment in a single procedure. Catheter ... use of a catheter makes it possible to combine diagnosis and treatment in a single procedure. An ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... resonance imaging (MRI) In catheter angiography, a thin plastic tube, called a catheter , is inserted into an ... The catheter used in angiography is a long plastic tube about as thick as a strand of ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... few millimeters) in the skin where the catheter can be inserted into an artery. The catheter is ... need for surgery. If surgery remains necessary, it can be performed more accurately. Catheter angiography presents a ...

  2. Estimation of current cumulative incidence of leukaemia-free patients and current leukaemia-free survival in chronic myeloid leukaemia in the era of modern pharmacotherapy

    Directory of Open Access Journals (Sweden)

    Trněný Marek

    2011-10-01

    Full Text Available Abstract Background The current situation in the treatment of chronic myeloid leukaemia (CML presents a new challenge for attempts to measure the therapeutic results, as the CML patients can experience multiple leukaemia-free periods during the course of their treatment. Traditional measures of treatment efficacy such as leukaemia-free survival and cumulative incidence are unable to cope with multiple events in time, e.g. disease remissions or progressions, and as such are inappropriate for the efficacy assessment of the recent CML treatment. Methods Standard nonparametric statistical methods are used for estimating two principal characteristics of the current CML treatment: the probability of being alive and leukaemia-free in time after CML therapy initiation, denoted as the current cumulative incidence of leukaemia-free patients; and the probability that a patient is alive and in any leukaemia-free period in time after achieving the first leukaemia-free period on the CML treatment, denoted as the current leukaemia-free survival. The validity of the proposed methods is further documented in the data of the Czech CML patients consecutively recorded between July 2003 and July 2009 as well as in simulated data. Results The results have shown a difference between the estimates of the current cumulative incidence function and the common cumulative incidence of leukaemia-free patients, as well as between the estimates of the current leukaemia-free survival and the common leukaemia-free survival. Regarding the currently available follow-up period, both differences have reached the maximum (12.8% and 20.8%, respectively at 3 years after the start of follow-up, i.e. after the CML therapy initiation in the former case and after the first achievement of the disease remission in the latter. Conclusions Two quantities for the evaluation of the efficacy of current CML therapy that may be estimated with standard nonparametric methods have been proposed in

  3. Measurement error correction for the cumulative average model in the survival analysis of nutritional data: application to Nurses' Health Study.

    Science.gov (United States)

    Qiu, Weiliang; Rosner, Bernard

    2010-01-01

    The use of the cumulative average model to investigate the association between disease incidence and repeated measurements of exposures in medical follow-up studies can be dated back to the 1960s (Kahn and Dawber, J Chron Dis 19:611-620, 1966). This model takes advantage of all prior data and thus should provide a statistically more powerful test of disease-exposure associations. Measurement error in covariates is common for medical follow-up studies. Many methods have been proposed to correct for measurement error. To the best of our knowledge, no methods have been proposed yet to correct for measurement error in the cumulative average model. In this article, we propose a regression calibration approach to correct relative risk estimates for measurement error. The approach is illustrated with data from the Nurses' Health Study relating incident breast cancer between 1980 and 2002 to time-dependent measures of calorie-adjusted saturated fat intake, controlling for total caloric intake, alcohol intake, and baseline age.

  4. Telomere length is a biomarker of cumulative oxidative stress, biologic age, and an independent predictor of survival and therapeutic treatment requirement associated with smoking behavior.

    Science.gov (United States)

    Babizhayev, Mark A; Savel'yeva, Ekaterina L; Moskvina, Svetlana N; Yegorov, Yegor E

    2011-11-01

    Globally, tobacco use is associated with 5 million deaths per annum and is regarded as one of the leading causes of premature death. Major chronic disorders associated with smoking include cardiovascular diseases, several types of cancer, and chronic obstructive pulmonary disease (lung problems). Cigarette smoking (CS) generates a cumulative oxidative stress, which may contribute to the pathogenesis of chronic diseases. Mainstream and side stream gas-phase smoke each have about the same concentration of reactive free radical species, about 1 × 10(16) radicals per cigarette (or 5 × 10(14) per puff). This effect is critical in understanding the biologic effects of smoke. Several lines of evidence suggest that cigarette smoke constituents can directly activate vascular reactive oxygen species production. In this work we present multiple evidence that CS provide the important risk factors in many age-related diseases, and is associated with increased cumulative and systemic oxidative stress and inflammation. The cited processes are marked by increased white blood cell (leucocytes, WBCs) turnover. The data suggest an alteration of the circulating WBCs by CS, resulting in increased adherence to endothelial cells. Telomeres are complex DNA-protein structures located at the end of eukaryotic chromosomes. Telomere length shortens with biologic age in all replicating somatic cells. It has been shown that tobacco smoking enhances telomere shortening in circulating human WBCs. Telomere attrition (expressed in WBCs) can serve as a biomarker of the cumulative oxidative stress and inflammation induced by smoking and, consequently, show the pace of biologic aging. We originally propose that patented specific oral formulations of nonhydrolized carnosine and carcinine provide a powerful tool for targeted therapeutic inhibition of cumulative oxidative stress and inflammation and protection of telomere attrition associated with smoking. The longitudinal studies of the clinical

  5. Cumulative scores based onplasma D-dimer andserum albumin levels predict survival inesophageal squamous cell carcinoma patients treated withtransthoracic esophagectomy

    Institute of Scientific and Technical Information of China (English)

    DeQingLiu; FangFangLi; WeiHuaJia

    2016-01-01

    Background:Recently, studies have shown that plasma D‑dimer and serum albumin are prognostic markers for esophageal cancer. The purpose of this study was to evaluate a novel prognostic scoring system—DA score (combi‑nation of preoperative plasma D‑dimer and serum albumin levels)—and analyze the association between survival of patients with esophageal squamous cell carcinoma (ESCC) and their Glasgow prognostic score. Methods:In this retrospective study, preoperative biochemical markers and clinicopathologic factors in 260 ESCC patients treated with transthoracic esophagectomy were reviewed. According to receiver operating characteristic analysis, the cutoff values of D‑dimer and albumin were deifned as 0.5μg/mL and 43.8g/L, respectively. Patients with high D‑dimer levels (≥0.5μg/mL) and low albumin levels (<43.8g/L) were assigned a score of 2, those with only one of the two abnormalities were assigned a score of 1, and those with neither of the two abnormalities were assigned a score of 0. Results:ESCC patients with a DA score of 0, 1, and 2 numbered 55, 116, and 89, respectively. Survival analysis showed that patients with a DA score of 2 had lower overall survival (OS) rates than those with DA scores of 1 and 0 (37.1% vs. 52.6% and 76.4%,P<0.001); similar ifndings were observed for disease‑free survival (DFS) rates (32.6% vs. 44.8% and 67.3%,P<0.001). In addition, the predictive value of the DA score was also signiifcant in patients with stages I–IIA and stages IIB–IV ESCC. Multivariate Cox regression analyses indicated that hazard ratios (HRs) for predicting OS of patients with DA scores 1 and 2 were 2.25 (P=0.010) and 3.14 (P<0.001), respectively, compared with those with a DA score of 0, and HRs for predicting DFS of patients with DA scores of 1 and 2 were 1.86 (P=0.023) and 2.68 (P<0.001), respectively, compared with those with a DA scores of 0. Conclusions:Our study suggests that preoperative DA scores are notably associated with

  6. Catheter tract implantation metastases associated with percutaneous biliary drainage for extrahepatic cholangiocarcinoma

    Institute of Scientific and Technical Information of China (English)

    Jun Sakata; Yoshio Shirai; Toshifumi Wakai; Tatsuya Nomura; Eiko Sakata; Katsuyoshi Hatakeyama

    2005-01-01

    AIM: To estimate the incidence of catheter tract implantation metastasis among patients undergoing percutaneous transhepatic biliary drainage (PTBD) for extrahepatic cholangiocarcinoma, and to provide data regarding the management of this unusual complication of PTBD by reviewing cases reported in the literature.METHODS: A retrospective analysis of 67 consecutive patients who underwent PTBD before the resection of extrahepatic cholangiocarcinoma was conducted. The median follow-up period after PTBD was 106 mo. The English language literature (PubMed, National Library of Medicine, Bethesda, MD, USA), from January 1966through December 2004, was reviewed.RESULTS: Catheter tract implantation metastasis developed in three patients. The cumulative incidence of implantation metastasis reached a plateau (6%)at 20 mo after PTBD. All of the three patients with implantation metastasis died of tumor progression at 3, 9, and 20 mo after the detection of this complication. Among the 10 reported patients with catheter tract implantation metastasis from extrahepatic cholangiocarcinoma (including our three patients), two survived for more than 5 years after the excision of isolated catheter tract metastases.CONCLUSION: Catheter tract implantation metastasis is not a rare complication following PTBD for extrahepatic cholangiocarcinoma. Although the prognosis for patients with this complication is generally poor, the excision of the catheter tract may enable survival in selected patients with isolated metastases along the catheter tract.

  7. Catheter Angiography

    Medline Plus

    Full Text Available ... What are the limitations of Catheter Angiography? What is Catheter Angiography? Angiography is a minimally invasive medical ... them appear bright white. top of page How is the procedure performed? This examination is usually done ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... using: x-rays with catheters computed tomography (CT) magnetic resonance imaging (MRI) In catheter angiography, a thin plastic tube, ... blood flow to the brain and cause a stroke. identify a small aneurysm or arteriovenous malformation (abnormal ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available ... it will make the rest of the procedure pain-free. You will not feel the catheter in ... nurse if you notice any bleeding, swelling or pain at the site where the catheter entered the ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... an artery through a small incision in the skin. Once the catheter is guided to the area ... small incision (usually a few millimeters) in the skin where the catheter can be inserted into an ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available ... should inform the nurse if you notice any bleeding, swelling or pain at the site where the ... Rarely, the catheter punctures the artery, causing internal bleeding. It also is possible that the catheter tip ...

  13. Catheter Angiography

    Medline Plus

    Full Text Available ... most cases, the kidneys will regain their normal function within five to seven days. Rarely, the catheter ... limitations of Catheter Angiography? Patients with impaired kidney function, especially those who also have diabetes, are not ...

  14. Influence of pretreatment systolic blood pressure on the effect of carvedilol in patients with severe chronic heart failure: the Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) study.

    Science.gov (United States)

    Rouleau, Jean L; Roecker, Ellen B; Tendera, Michal; Mohacsi, Paul; Krum, Henry; Katus, Hugo A; Fowler, Michael B; Coats, Andrew J S; Castaigne, Alain; Scherhag, Armin; Holcslaw, Terry L; Packer, Milton

    2004-04-21

    We sought to evaluate the influence of pretreatment systolic blood pressure (SBP) on the efficacy and safety of carvedilol in patients with chronic heart failure (CHF). Although beta-blockers reduce the risk of death in CHF, there is little reported experience with these drugs in patients with a low pretreatment SBP, who may respond poorly to beta-blockade. We studied 2,289 patients with severe CHF who participated in the Carvedilol Prospective Randomized Cumulative Survival (COPERNICUS) trial. Compared with placebo, carvedilol improved the clinical status and reduced the risk of death and the combined risk of death or hospitalization for any reason, for a cardiovascular reason, or for worsening heart failure (p 0.10). However, because patients with the lowest SBP were at highest risk of an event, they experienced the greatest absolute benefit from treatment with carvedilol. The lower the pretreatment SBP, the more likely that patients would report an adverse event, be intolerant of high doses of the study drug, or require permanent withdrawal of treatment (p < 0.001 for all). However, these risks were primarily related to the severity of the underlying illness and not to treatment with carvedilol. The current study provides little support for concerns about using beta-blockers (particularly those with vasodilatory actions) in patients with severe CHF who have a low SBP. Pretreatment blood pressure can identify patients who have the greatest need for risk reduction with carvedilol.

  15. Catheter Angiography

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Catheter angiography is used to examine blood ... an hour away. top of page What does the equipment look like? The equipment typically used for ...

  16. Catheter Angiography

    Medline Plus

    Full Text Available ... medical conditions. Angiography uses one of three imaging technologies and, in most cases, a contrast material injection ... Angiography (CTA) X-ray, Interventional Radiology and Nuclear Medicine Radiation Safety Images related to Catheter Angiography Sponsored ...

  17. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... iodine. If angiography is essential, a variety of methods is used to decrease risk of allergy: You ...

  18. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  19. Catheter Angiography

    Medline Plus

    Full Text Available ... may also be asked to remove jewelry, removable dental appliances, eye glasses and any metal objects or ... it will make the rest of the procedure pain-free. You will not feel the catheter in ...

  20. Catheter Angiography

    Medline Plus

    Full Text Available ... injection of contrast material to examine blood vessels in key areas of the body for abnormalities such ... makes it possible to combine diagnosis and treatment in a single procedure. Catheter angiography produces very detailed, ...

  1. Catheter Angiography

    Medline Plus

    Full Text Available ... a catheter, x-ray imaging guidance and an injection of contrast material to examine blood vessels in ... technologies and, in most cases, a contrast material injection is needed to produce pictures of blood vessels ...

  2. Catheter Angiography

    Medline Plus

    Full Text Available ... X-rays are a form of radiation like light or radio waves. X-rays pass through most ... catheter angiography to lessen the risk of allergic reaction. Another option is to undergo a different exam ...

  3. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a ... these links. About Us | Contact Us | FAQ | Privacy | Terms of Use | Links | Site Map Copyright © 2017 Radiological ...

  4. Catheter Angiography

    Medline Plus

    Full Text Available ... you are pregnant and discuss any recent illnesses, medical conditions, medications you're taking and allergies, especially ... is Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical ...

  5. Catheter Angiography

    Medline Plus

    Full Text Available ... atherosclerosis (plaque). The use of a catheter makes it possible to combine diagnosis and treatment in a ... the aorta in the chest or abdomen or its major branches. show the extent and severity of ...

  6. Catheter Angiography

    Medline Plus

    Full Text Available ... of page What are some common uses of the procedure? Catheter angiography is used to examine blood ... an hour away. top of page What does the equipment look like? The equipment typically used for ...

  7. Urinary catheters

    Science.gov (United States)

    ... incontinence. There is no tube placed inside the penis. Instead, a condom-like device is placed over the penis. A tube leads from this device to a ... too small Bladder spasms Constipation The wrong balloon size Urinary tract infections POSSIBLE COMPLICATIONS Complications of catheter ...

  8. Catheter Angiography

    Medline Plus

    Full Text Available ... Español More Info Images/Videos About Us News Physician Resources Professions Site Index A-Z Catheter Angiography ... may eliminate the need for surgery. Tell your doctor if there's a possibility you are pregnant and ...

  9. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  10. Catheter Angiography

    Medline Plus

    Full Text Available ... spaghetti. top of page How does the procedure work? Catheter angiography works much the same as a regular x-ray ... any possibility that they are pregnant. See the Safety page for more information about pregnancy and x- ...

  11. Catheter Angiography

    Medline Plus

    Full Text Available ... images are captured using a small dose of ionizing radiation ( x-rays ). top of page What are some common uses of the procedure? Catheter angiography is used to examine blood vessels in key areas of the body, including the: brain neck heart chest abdomen (such as the kidneys ...

  12. Catheter Angiography

    Medline Plus

    Full Text Available Toggle navigation Test/Treatment Patient Type Screening/Wellness Disease/Condition Safety En Español More Info Images/Videos About Us News Physician ... Catheter Angiography? Angiography is a minimally invasive medical test that helps physicians diagnose and treat medical conditions. ...

  13. Patency and Complications of Translumbar Dialysis Catheters.

    Science.gov (United States)

    Liu, Fanna; Bennett, Stacy; Arrigain, Susana; Schold, Jesse; Heyka, Robert; McLennan, Gordon; Navaneethan, Sankar D

    2015-01-01

    Translumbar tunneled dialysis catheter (TLDC) is a temporary dialysis access for patients exhausted traditional access for dialysis. While few small studies reported successes with TLDC, additional studies are warranted to understand the short- and long-term patency and safety of TLDC. We conducted a retrospective analysis of adult patients who received TLDC for hemodialysis access from June 2006 to June 2013. Patient demographics, comorbid conditions, dialysis details, catheter insertion procedures and associated complications, catheter patency, and patient survival data were collected. Catheter patency was studied using Kaplan-Meier curve; catheter functionality was assessed with catheter intervals and catheter-related complications were used to estimate catheter safety. There were 84 TLDCs inserted in 28 patients with 28 primary insertions and 56 exchanges. All TLDC insertions were technically successful with good blood flow during dialysis (>300 ml/minute) and no immediate complications (major bleeding or clotting) were noted. The median number of days in place for initial catheter, secondary catheter, and total catheter were 65, 84, and 244 respectively. The catheter patency rate at 3, 6, and 12 months were 43%, 25%, and 7% respectively. The main complications were poor blood flow (40%) and catheter-related infection (36%), which led to 30.8% and 35.9% catheter removal, respectively. After translumbar catheter, 42.8% of the patients were successfully converted to another vascular access or peritoneal dialysis. This study data suggest that TLDC might serve as a safe, alternate access for dialysis patients in short-term who have exhausted conventional vascular access. © 2015 Wiley Periodicals, Inc.

  14. Survival

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — These data provide information on the survival of California red-legged frogs in a unique ecosystem to better conserve this threatened species while restoring...

  15. Hemodialysis Tunneled Catheter Noninfectious Complications

    Science.gov (United States)

    Miller, Lisa M.; MacRae, Jennifer M.; Kiaii, Mercedeh; Clark, Edward; Dipchand, Christine; Kappel, Joanne; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; Pike, Pamela; Hiremath, Swapnil

    2016-01-01

    Noninfectious hemodialysis catheter complications include catheter dysfunction, catheter-related thrombus, and central vein stenosis. The definitions, causes, and treatment strategies for catheter dysfunction are reviewed below. Catheter-related thrombus is a less common but serious complication of catheters, requiring catheter removal and systemic anticoagulation. In addition, the risk factors, clinical manifestation, and treatment options for central vein stenosis are outlined.

  16. The Soft Cumulative Constraint

    CERN Document Server

    Petit, Thierry

    2009-01-01

    This research report presents an extension of Cumulative of Choco constraint solver, which is useful to encode over-constrained cumulative problems. This new global constraint uses sweep and task interval violation-based algorithms.

  17. Effect of ultra-low dose and standard heparin locks on early tunnelled dialysis catheter outcomes in low-risk dialysis patients.

    Science.gov (United States)

    Renaud, Claude J; Lim, Eng Kuang; Tho, Samuel J; Yeoh, Lee Ying

    2015-02-01

    Initial heparin locks instilled after tunnelled dialysis catheter (TDC) insertion can leak causing systemic anticoagulation and also promote staphyloccocal biofilm formation, predisposing to catheter-related infection (CRI). The 1000 U/mL concentration is thus advocated as the optimal dose for preventing catheter bleeding and malfunction. The effect of lower heparin concentrations on further lowering these complications is not known. We compared early TDC outcomes between a non-standard ultra-low (500 U/mL) and standard initial heparin locks (1000 and 5000 U/mL). This was a retrospective study on prospectively collected data on 238 de novo internal jugular TDCs placed by nephrologists. Cases were categorized into groups 1, 2 and 3, according to initial heparin lock: 500 [n = 30], 1000 [n = 180] and 5000 U/mL [n = 28] respectively. Bleeding and malfunction within 24 h of TDC insertion, 30 days CRI-free catheter survival and the effects of clinical and laboratory factors on bleeding were evaluated. Bleeding events were similar in groups 1, 2 and 3 (7 vs 14 vs 13%, respectively, P = 0.61). Malfunction was only seen in group 2 (3.3%). Thirty-day CRI-free catheter survival was comparable (96 vs 98 vs 97%, respectively, P = 0.22), giving a cumulative CRI rate of 0.76/1000 catheter days. All CRIs were staphylococcal. Univariate analysis did not reveal any significant predictors of catheter bleeding. Immediate TDC bleeding, malfunction and CRI rate are not influenced by heparin lock concentrations ≤5000 U/mL in this low-risk cohort. However this needs to be corroborated in higher risk patients. © 2014 Asian Pacific Society of Nephrology.

  18. Experience of robotic catheter ablation in humans using a novel remotely steerable catheter sheath

    Science.gov (United States)

    Wallace, Daniel T.; Goldenberg, Alex S.; Peters, Nicholas S.; Davies, D. Wyn

    2008-01-01

    Background A novel remotely controlled steerable guide catheter has been developed to enable precise manipulation and stable positioning of any eight French (Fr) or smaller electrophysiological catheter within the heart for the purposes of mapping and ablation. Objective To report our initial experience using this system for remotely performing catheter ablation in humans. Methods Consecutive patients attending for routine ablation were recruited. Various conventional diagnostic catheters were inserted through the left femoral vein in preparation for treating an accessory pathway (n = 1), atrial flutter (n = 2) and atrial fibrillation (n = 7). The steerable guide catheter was inserted into the right femoral vein through which various irrigated and non-irrigated tip ablation catheters were used. Conventional endpoints of loss of pathway conduction, bidirectional cavotricuspid isthmus block and four pulmonary vein isolation were used to determine acute procedural success. Results Ten patients underwent remote catheter ablation using conventional and/or 3D non-fluoroscopic mapping technologies. All procedural endpoints were achieved using the robotic control system without manual manipulation of the ablation catheter. There was no major complication. A radiation dosimeter positioned next to the operator 2.7 m away from the X-ray source showed negligible exposure despite a mean cumulative dose area product of 7,281.4 cGycm2 for all ten ablation procedures. Conclusions Safe and clinically effective remote navigation of ablation catheters can be achieved using a novel remotely controlled steerable guide catheter in a variety of arrhythmias. The system is compatible with current mapping and ablation technologies Remote navigation substantially reduces radiation exposure to the operator. Electronic supplementary material The online version of this article (doi:10.1007/s10840-007-9184-z) contains supplementary material, which is available to authorized users

  19. Central venous catheters and catheter locks in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Schrøder, Henrik

    2013-01-01

    To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC).......To determine if the catheter lock taurolidine can reduce the number of catheter-related bloodstream infections (CRBSI) in pediatric cancer patients with tunneled central venous catheters (CVC)....

  20. Radiologically placed tunneled peritoneal catheter in palliation of malignant ascites

    Energy Technology Data Exchange (ETDEWEB)

    Akinci, Devrim; Erol, Bekir; Ciftci, Tuerkmen T. [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey); Akhan, Okan, E-mail: akhano@tr.net [Hacettepe University, Faculty of Medicine, Department of Radiology, 06100 Ankara (Turkey)

    2011-11-15

    The purpose of this study was to evaluate retrospectively the safety and effectiveness of radiologically placed tunneled peritoneal catheter in palliation of malignant ascites. Between July 2005 and June 2009, 41 tunneled peritoneal catheters were placed under ultrasonographic and fluoroscopic guidance in 40 patients (mean age, 55 years; 22 women) who had symptomatic malignant ascites. No procedure related mortality was observed. Major complication occurred in one patient (2.5%) in the form of serious bacterial peritonitis that necessitated catheter removal. Minor complications such as minor bacterial peritonitis, catheter dislodgement, tunnel infection, and catheter blockage occurred in 11 patients (27.5%). The mean duration of survival after catheter placement was 11.8 weeks. All patients expired of their primary malignancies in the follow-up. Radiologically placed tunneled peritoneal catheter is safe and effective in palliation of symptomatic malignant ascites.

  1. Central venous catheter - flushing

    Science.gov (United States)

    ... during cancer treatment Bone marrow transplant - discharge Central venous catheter - dressing change Peripherally inserted central catheter - flushing Sterile technique Surgical wound care - open Review Date 9/22/2016 Updated by: ...

  2. Cytometric Catheter for Neurosurgical Applications

    Energy Technology Data Exchange (ETDEWEB)

    Evans III, Boyd Mccutchen [ORNL; Allison, Stephen W [ORNL; Fillmore, Helen [ORNL; Broaddus, William C [ORNL; Dyer, Rachel L [ORNL; Gillies, George [ORNL

    2010-01-01

    Implantation of neural progenitor cells into the central nervous system has attracted strong interest for treatment of a variety of pathologies. For example, the replacement of dopamine-producing (DA) neural cells in the brain appears promising for the treatment of patients affected by Parkinson's disease. Previous studies of cell-replacement strategies have shown that less than 90% of implanted cells survive longer than 24 - 48 hours following the implantation procedure. However, it is unknown if these cells were viable upon delivery, or if they were affected by other factors such as brain pathology or an immune response. An instrumented cell-delivery catheter has been developed to assist in answering these questions by facilitating quantification and monitoring of the viability of the cells delivered. The catheter uses a fiber optic probe to perform flourescence-based cytometric measurments on cells exiting the port at the catheter tip. The current implementation of this design is on a 3.2 mm diameter catheter with 245 micrometer diameter optical fibers. Results of fluorescence testing data are presented and show that the device can characterize the quantity of cell densities ranging from 60,000 cells/ml to 600,000 cells/ml with a coefficient of determination of 0.93.

  3. Radiologic Placement of Tunneled Central Venous Catheters in Pediatric Patients

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Eun Ji; Song, Soon Young; Cho, On Koo; Koh, Byung Hee; Kim, Yong Soo; Jeong, Woo Kyoung; Lee, Yong Ho [Hanyang University College of Medicine, Seoul (Korea, Republic of)

    2010-08-15

    We evaluated the technical success and complication rates associated with the radiological placement of tunneled central venous catheters in pediatric patients. Between May 1, 2005 and March 31, 2008, a total of 46 tunneled central venous catheters were placed in 34 children (M:F = 22:12; mean age, 9.9 years [9 months to 16.8 years]). All procedures were performed under ultrasonographic and fluoroscopic guidance. Follow-up data were obtained through the retrospective review of the medical records. We used the Kaplan-Meier survival method for the evaluation of survival rate of the catheters. All procedures were technically successful. The observed periprocedural complications included hematoma formation in three patients. The mean catheter life was 189.3 days (total, 8710 days; range, 7-810). Catheters were removed due to death (n=9), the end of treatment (n=8), catheter sepsis (n=4), malfunction (n=8), and accidental removal (n=4). The rate of catheter sepsis and malfunction was 0.459 and 0.919 for every 1000 catheter days, respectively. The expected mean catheter life was 479.6 days as per the Kaplan- Meier analysis. The results suggest that the radiologic placement of a tunneled central venous catheter is an effective technique with a high technical success rate and low complication rate.

  4. Comparison of outcomes between surgically placed and percutaneously placed peritoneal dialysis catheters: A retrospective study

    Science.gov (United States)

    Sivaramakrishnan, R.; Gupta, S.; Agarwal, S. K.; Bhowmik, D.; Mahajan, S.

    2016-01-01

    There is lack of adequate data on comparison of outcomes between percutaneously placed peritoneal dialysis (PD) catheters inserted by nephrologists and PD catheters placed by surgeons. The aim of this study is to retrospectively analyze the outcomes of PD catheters inserted by surgeons (by open surgical or laparoscopic technique) and compare them with those inserted by nephrologists among ESRD patients who underwent elective PD catheter insertions between January 2009 and December 2012. The primary outcome measure was the proportion of catheters removed because of primary nonfunction. The secondary outcome measures were catheter survival, patient survival, and incidence of complications of catheter insertion. A total of 143 PD catheter insertions (88 by surgeons and 55 by nephrologists) performed in 132 patients were considered for the analysis. The primary nonfunction rate of PD catheter insertions in both groups was comparable (18.2% and 7.3%, P = 0.08). Break-in period was shorter in Group N (p = <0.001). No differences were noted in patient or catheter survival. Percutaneously placed PD catheters performed by nephrologists have comparable outcomes with surgically placed PD catheters among selected cases and have the advantage of lower costs, avoidance of operation theater scheduling issues, smaller incision length, and shorter break-in period. Therefore, more nephrologists should acquire the expertise on percutaneous PD catheter placement as it leads to lesser waiting times and better utilization of PD. PMID:27512299

  5. Use of iliac vein tunneled cuffed catheters in elderly hemodialysis patients: a single-center retrospective study.

    Science.gov (United States)

    Wang, Lihua; Wei, Fang; Sun, Guijiang; Chen, Haiyan; Yu, Haibo; Jiang, Aili

    2016-02-01

    Until now, the survival of iliac vein tunneled cuffed catheters (TCCs) used in elderly patients has not been fully investigated. Accordingly, we evaluated their use in elderly hemodialysis patients with no other venous access options. A total of 70 elderly patients with iliac vein TCCs undergoing chronic hemodialysis were included in this study. Patients' baseline anthropometric and laboratory parameters were measured. Incidence of catheter dysfunction and of catheter-related infection was documented. During the study period, a total of 99 new tunneled dialysis catheters were placed. Technical success rate was 100 %. Median infection-free survival and dysfunction-free survival after catheterization was 617 and 875 catheter days, respectively. Mean survival time per catheter was 1067 catheter days, corresponding to a total observation period of 65369 catheters days. Iliac TCC is both technically feasible and effective for hemodialysis in elderly patients with no other venous access options.

  6. Biological safety evaluation of the modified urinary catheter

    Energy Technology Data Exchange (ETDEWEB)

    Kowalczuk, Dorota, E-mail: dorota.kowalczuk@umlub.pl [Department of Medicinal Chemistry, Medical University of Lublin, Jaczewskiego 4, 20-090 Lublin (Poland); Przekora, Agata; Ginalska, Grazyna [Department of Biochemistry and Biotechnology, Medical University of Lublin, Chodzki 1, 20-093 Lublin (Poland)

    2015-04-01

    The purpose of this study was to evaluate in vitro safety of the novel tosufloxacin (TOS)-treated catheters with the prolonged antimicrobial activity. The test samples of silicone latex catheter were prepared by the immobilization of TOS on chitosan (CHIT)-coated catheter by means of covalent bonds and non-covalent interactions. Each step of the modification process of catheter surface was observed using ATR–Fourier transform infrared spectroscopy. In vitro cytotoxicity of the modified and unmodified catheters was assessed by direct and indirect tests in accordance with ISO standards using green monkey kidney (GMK) cell line. The MTT, lactate dehydrogenase activity (LDH), WST-8, Sulforhodamine B (SRB) test results and microscopic observation clearly indicated that unmodified silicone latex catheters decrease cell metabolic activity, act as a cytotoxic agent causing cell lysis and induce cell death through necrotic or apoptotic process. We suggest that chitosan coat with TOS immobilized limits leaching of harmful agents from silicone latex material, which significantly enhances survivability of GMK cells and therefore is quite a good protection against the cytotoxic effect of this material. - Highlights: • Characterization of the novel antimicrobial urinary catheters • Monitoring of the catheter modification by FTIR analysis • Confirmation of high cytotoxicity of latex-based catheter used in urological practice • Chitosan-coated and tosufloxacin-treated catheter is less toxic than the untreated one. • The proposed surface modification protects cells against latex-induced death.

  7. Indwelling urethral catheters in adults

    OpenAIRE

    Calleja, Edward

    2012-01-01

    This article focuses on indwelling urethral catheters in adults, their indications for the short and long term use, the types of urinary catheters available in Malta, an overview of the basic structure of a catheter, and the complications of urinary catheter insertion and maintenance. An attempt has been made to address in some depth the most common complication of indwelling catheterscatheter associated urinary tract infection in terms of pathophysiology and its management. Simple but cru...

  8. [The bladder catheter].

    Science.gov (United States)

    Pestalozzi, D M

    1996-09-01

    The benefit of the transurethral catheter to protect or measure renal function is well accepted. Urethral stricture and infection of the lower urinary tract as the complications should lead to a cautious use of catheters. A careful placement, the choice of the best material and a correct management help to avoid complications. Alternatives are discussed.

  9. Cumulative fatigue damage models

    Science.gov (United States)

    Mcgaw, Michael A.

    1988-01-01

    The problem of calculating expected component life under fatigue loading conditions is complicated by the fact that component loading histories contain, in many cases, cyclic loads of widely varying amplitudes. In such a case a cumulative damage model is required, in addition to a fatigue damage criterion, or life relationship, in order to compute the expected fatigue life. The traditional cumulative damage model used in design is the linear damage rule. This model, while being simple to use, can yield grossly unconservative results under certain loading conditions. Research at the NASA Lewis Research Center has led to the development of a nonlinear cumulative damage model, named the double damage curve approach (DDCA), that has greatly improved predictive capability. This model, which considers the life (or loading) level dependence of damage evolution, was applied successfully to two polycrystalline materials, 316 stainless steel and Haynes 188. The cumulative fatigue behavior of the PWA 1480 single-crystal material is currently being measured to determine the applicability of the DDCA for this material.

  10. Suprapubic catheter care

    Science.gov (United States)

    ... urine bag only a few times a day. Caring for Your Skin Near your Catheter Follow these ... Bethesda, MD 20894 U.S. Department of Health and Human Services National Institutes of Health Page last updated: ...

  11. Serratia marcescens bacteraemia outbreak in haemodialysis patients with tunnelled catheters due to colonisation of antiseptic solution. Experience at 4 hospitals

    Directory of Open Access Journals (Sweden)

    José L. Merino

    2016-11-01

    Conclusions: The presence of bacteraemia due to unconventional germs should alert us to a potential outbreak. The application of a solution contaminated by S. marcescens in haemodialysis catheters was the source of bacteraemia. The intravenous antibiotic treatment and the catheter lock solution allowed an excellent survival of patients and catheters.

  12. Natural history of tunneled dialysis catheters placed for hemodialysis initiation.

    Science.gov (United States)

    Shingarev, Roman; Barker-Finkel, Jill; Allon, Michael

    2013-09-01

    More than 80% of hemodialysis recipients in the United States initiate hemodialysis with a tunneled dialysis catheter (TDC). Published data on TDC outcomes are based on a case mix of prevalent and incident TDCs. The present study analyzes factors affecting patency and complications of first TDCs placed in a large cohort of incident hemodialysis recipients. A prospective, computerized vascular access database was retrospectively queried to identify 472 patients receiving a first-ever TDC. Multiple-variable survival analysis was used to identify clinical parameters affecting TDC patency (from placement to nonelective removal) and infection (from placement to first episode of catheter-related bacteremia [CRB]). The median patency of all TDCs was 202 days. Left-sided placement of TDCs was the only variable associated with inferior TDC patency (hazard ratio, 1.98; 95% confidence interval, 1.39-2.81; P catheters, versus 54% for right internal jugular vein (RIJV) catheters. The 1-year patency rate was 6% for LIJV catheters, versus 35% for RIJV catheters. Catheter patency was not associated with patient age, sex, race, hypertension, diabetes, coronary artery disease, peripheral vascular disease, cerebrovascular disease, or heart failure. The median time to the first episode of CRB was 163 days. None of the clinical variables was associated with TDC infection. TDCs are plagued by high rates of infection. RIJV TDCs should be used preferentially to maximize catheter patency. Copyright © 2013 SIR. Published by Elsevier Inc. All rights reserved.

  13. Dedicated radial ventriculography pigtail catheter

    Energy Technology Data Exchange (ETDEWEB)

    Vidovich, Mladen I., E-mail: miv@uic.edu

    2013-05-15

    A new dedicated cardiac ventriculography catheter was specifically designed for radial and upper arm arterial access approach. Two catheter configurations have been developed to facilitate retrograde crossing of the aortic valve and to conform to various subclavian, ascending aortic and left ventricular anatomies. The “short” dedicated radial ventriculography catheter is suited for horizontal ascending aortas, obese body habitus, short stature and small ventricular cavities. The “long” dedicated radial ventriculography catheter is suited for vertical ascending aortas, thin body habitus, tall stature and larger ventricular cavities. This new design allows for improved performance, faster and simpler insertion in the left ventricle which can reduce procedure time, radiation exposure and propensity for radial artery spasm due to excessive catheter manipulation. Two different catheter configurations allow for optimal catheter selection in a broad range of patient anatomies. The catheter is exceptionally stable during contrast power injection and provides equivalent cavity opacification to traditional femoral ventriculography catheter designs.

  14. Cumulative Timers for Microprocessors

    Science.gov (United States)

    Battle, John O.

    2007-01-01

    It has been proposed to equip future microprocessors with electronic cumulative timers, for essentially the same reasons for which land vehicles are equipped with odometers (total-distance-traveled meters) and aircraft are equipped with Hobbs meters (total-engine-operating time meters). Heretofore, there has been no way to determine the amount of use to which a microprocessor (or a product containing a microprocessor) has been subjected. The proposed timers would count all microprocessor clock cycles and could only be read by means of microprocessor instructions but, like odometers and Hobbs meters, could never be reset to zero without physically damaging the chip.

  15. Cumulative Vehicle Routing Problems

    OpenAIRE

    Kara, &#;mdat; Kara, Bahar Yeti&#;; Yeti&#;, M. Kadri

    2008-01-01

    This paper proposes a new objective function and corresponding formulations for the vehicle routing problem. The new cost function defined as the product of the distance of the arc and the flow on that arc. We call a vehicle routing problem with this new objective function as the Cumulative Vehicle Routing Problem (CumVRP). Integer programming formulations with O(n2) binary variables and O(n2) constraints are developed for both collection and delivery cases. We show that the CumVRP is a gener...

  16. Central venous catheter - dressing change

    Science.gov (United States)

    ... during cancer treatment Bone marrow transplant - discharge Central venous catheter - flushing Peripherally inserted central catheter - flushing Sterile technique Surgical wound care - open Review Date 9/17/2016 Updated by: ...

  17. Cumulative environmental effects. Summary

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2012-07-01

    This report presents a compilation of knowledge about the state of the environment and human activity in the Norwegian part of the North Sea and Skagerrak. The report gives an overview of pressures and impacts on the environment from normal activity and in the event of accidents. This is used to assess the cumulative environmental effects, which factors have most impact and where the impacts are greatest, and to indicate which problems are expected to be most serious in the future. The report is intended to provide relevant information that can be used in the management of the marine area in the future. It also provides input for the identification of environmental targets and management measures for the North Sea and Skagerrak.(Author)

  18. Electrifying catheters with light

    NARCIS (Netherlands)

    M. Pekař (Martin); J. Van Rens (Jeannet); M.B. van der Mark (Martin)

    2017-01-01

    textabstractSmart minimally invasive devices face a connectivity challenge. An example is found in intracardiac echocardiography where the signal transmission and supply of power at the distal end require many thin and fragile wires in order to keep the catheter slim and flexible. We have built a

  19. Restoration of patency in failing tunneled hemodialysis catheters: a comparison of catheter exchange, exchange and balloon disruption of the fibrin sheath, and femoral stripping.

    Science.gov (United States)

    Janne d'Othée, Bertrand; Tham, Jacques C; Sheiman, Robert G

    2006-06-01

    To compare median patency times after treatment of malfunctioning tunneled hemodialysis catheters by one of three techniques: over-the-wire catheter exchange (CE), fibrin sheath stripping (FSS) from a femoral vein approach, and over-the-wire catheter removal with balloon dilation of fibrin sheath (DFS) followed by catheter replacement with use of the same tract. Retrospective study was conducted of 66 consecutive procedures performed over a period of 47 months for poor flow through tunneled hemodialysis catheters despite tissue plasminogen activator infusion trials (CE, n=33; FSS, n=18; DFS, n=15). Baseline parameters (time since initial catheter placement, number of previous catheter interventions, catheter access site, and patient age and sex) were recorded to identify possible pretreatment differences among groups. Outcome comparison was based on duration of adequate catheter function on dialysis during follow-up. No significant differences in baseline parameters were identified among the three groups (P>.05). Mean follow-up duration (67+/-89 days; range, 0-398 d) was similar among the three groups. The immediate technical success rate was 100%, and there were no complications. Cumulative catheter patency rates were 73% (CE), 72% (FSS), and 65% (DFS) at 1 month; 43% (CE), 60% (FSS), and 39% (DFS) at 3 months; and 28% (CE), 45% (FSS), and 39% (DFS) at 6 months. Median duration of patency was similar among groups (P=.60). All three therapies were equivalent in terms of immediate technical success, complication rates, and durability of catheter function during later follow-up. Hence, when one technique is chosen over another, factors other than the period of secondary patency should be considered, such as cost and patient and physician preference.

  20. Establishing learning curve for Tenckhoff catheter insertion by interventional nephrologist using CUSUM analysis: how many procedures and in which situation?

    Science.gov (United States)

    Goh, Bak Leong; Ganeshadeva Yudisthra, M; Lim, Teck Onn

    2009-01-01

    Peritoneal dialysis (PD) catheter insertion success rate is known to vary among different operators, and peritoneoscope PD catheter insertion demands mastery of a steep learning curve. Defining a learning curve using a continuous monitoring tool such as a Cumulative Summation (CUSUM) chart is useful for planning training programs. We aimed to analyze the learning curve of a trainee nephrologist in performing peritoneoscope PD catheter implantation with CUSUM chart. This was a descriptive single-center study using collected data from all PD patients who underwent peritoneoscope PD catheter insertion in our hospital. CUSUM model was used to evaluate the learning curve for peritoneoscope PD catheter insertion. Unacceptable primary failure rate (i.e., catheter malfunction within 1 month of insertion) was defined at >40% and acceptable performance was defined at CUSUM chart showed the learning curve of a trainee in acquiring new skill. As the trainee became more skillful with training, the CUSUM curve flattened. Technical proficiency of the trainee nephrologist in performing peritoneoscope Tenckhoff catheter insertion (CUSUM charting as described to monitor primary catheter dysfunction (i.e., failure of catheter function within 1 month of insertion), primary leak (i.e., within 1 month of catheter insertion), and primary peritonitis (i.e., within 2 weeks of catheter insertion).

  1. UBIQUITOUS POLLUTANTS FROM CUMULATIVE ...

    Science.gov (United States)

    The occurrence of pharmaceuticals and personal care products (PPCPS) as environmental pollutants is a multifaceted issue whose scope continues to become better delineated since the escalation of concerted attention beginning in the 1980s. PPCPs typically occur as trace environmental pollutants (primarily in surface but also in ground waters) as a result of their widespread, continuous, combined usage in a broad range of human and veterinary therapeutic activities and practices. With respect to the risk-assessment paradigm, the growing body of published work has focused primarily on the origin and occurrence of these substances. Comparatively less is known about human and ecological exposure, and even less about the known or even potential hazards associated with exposure to these anthropogenic substances, many of which are highly bioactive. The continually growing, worldwide importance of freshwater resources underscores the need for ensuring that any aggregate or cumulative impacts on water supplies and resultant potential for human or ecological exposure be minimized. This has prompted the more recent investigations on waste treatment processes for one of the major sources of environmental disposition, namely sewage. Despite the paucity of health effects data for long-term, simultaneous exposure to multiple xenobiotics (particularly PPCPS) at low doses (a major toxicological issue that can be described by the

  2. Evaluation of catheter infection rates in converted dialysis catheters versus de novo placement in the setting of chlorhexidine use.

    Science.gov (United States)

    Criddle, Jared M; Hieb, Robert A; White, Sarah B; Patel, Parag J; Hohenwalter, Eric J; Tutton, Sean M; Rilling, William S

    2016-01-01

    Prior studies have reported infection rates of converting non-tunneled dialysis catheters (NTDCs) to tunneled dialysis catheters (TDCs) versus de novo placement of TDCs using povidone-iodine. Chlorhexidine, per the Center of Disease Control guidelines, has been exclusively used in our institution since 2005. Therefore, our study aims to determine whether there is a difference in infection rates between conversion and de novo placement when utilizing chlorhexidine. A retrospective analysis from 1/1/2009 to 8/10/2012 was performed of patients who underwent placement of NTDCs, which were subsequently converted to TDCs and those who underwent de novo TDC placement. To assess the rate of infection, the following data points were collected: date of procedure(s), indication, outcomes, site of catheter insertion, pre- and post-procedure laboratory values, complications, infection rates within the life of the initially placed catheter, catheter days, and survival. The conversion cohort was composed of 205 patients, 135 of whom were lost to follow-up, leaving 70 patients. The de novo cohort included 70 randomly selected patients. Of the 70 patients who underwent conversion, 23 developed a catheter-related infection, with an infection rate of 0.26 events per 100 catheter days. Of the 70 de novo catheters, 20 developed infection with an infection rate of 0.25 events per 100 catheters days. In this series, there is no difference in infection rates between conversion and de novo TDC placement when utilizing chlorhexidine as the sterilization agent. However, these infection rates are superior to those reported when using povidone-iodine.

  3. Electrifying catheters with light.

    Science.gov (United States)

    Pekař, Martin; van Rens, Jeannet; van der Mark, Martin B

    2017-04-17

    Smart minimally invasive devices face a connectivity challenge. An example is found in intracardiac echocardiography where the signal transmission and supply of power at the distal end require many thin and fragile wires in order to keep the catheter slim and flexible. We have built a fully functional bench-top prototype to demonstrate that electrical wires may be replaced by optical fibers. The prototype is immediately scalable to catheter dimensions. The absence of conductors will provide intrinsic galvanic isolation as well as radio frequency (RF) and magnetic resonance imaging (MRI) compatibility. Using optical fibers, we show signal transfer of synthetic aperture ultrasound images as well as photo-voltaic conversion to supply all electronics. The simple design utilizes only off the shelf components and holds a promise of cost effectiveness which may be pivotal for translation of these advanced devices into the clinic.

  4. Cumulate Fragments in Silicic Ignimbrites

    Science.gov (United States)

    Bachmann, O.; Ellis, B. S.; Wolff, J.

    2014-12-01

    Increasingly, studies are concluding that silicic ignimbrites are the result of the amalgamation of multiple discrete magma batches. Yet the existence of discrete batches presents a conundrum for magma generation and storage; if silicic magma batches are not generated nearly in situ in the upper crust, they must traverse, and reside within, a thermally hostile environment with large temperature gradients, resulting in low survivability in their shallow magmatic hearths. The Snake River Plain (Idaho, USA) is a type example of this 'multi-batch' assembly with ignimbrites containing multiple populations of pyroxene crystals, glass shards, and crystal aggregates. The ubiquitous crystal aggregates hint at a mechanism to facilitate the existence of multiple, relatively small batches of rhyolite in the upper crust. These aggregates contain the same plagioclase, pyroxene, and oxide mineral compositions as single phenocrysts of the same minerals in their host rocks, but they have significantly less silicic bulk compositions and lack quartz and sanidine, which occur as single phenocrysts in the deposits. This implies significant crystallization followed by melt extraction from mushy reservoir margins. The extracted melt then continues to evolve (crystallizing sanidine and quartz) while the melt-depleted margins provide an increasingly rigid and refractory network segregating the crystal-poor batches of magma. The hot, refractory, margins insulate the crystal-poor lenses, allowing (1) extended residence in the upper crust, and (2) preservation of chemical heterogeneities among batches. In contrast, systems that produce cumulates richer in low-temperature phases (quartz, K-feldspars, and/or biotite) favour remelting upon recharge, leading to less segregation of eruptible melt pockets and the formation of gradationally zoned ignimbrites. The occurrence of similar crystal aggregates from a variety of magmatic lineages suggests the generality of this process.

  5. Two years experience with tunneled dialysis catheters in patients requiring haemodialysis.

    Science.gov (United States)

    Raheem, Abdur; Rana, Atif Iqbal; Mehmood, Syed Nayer; Ramzan, Mubashir; Shah, Rustam Alam; Naseem, Sajida

    2014-07-01

    To look for survival rate and major reasons behind the failure of tunnelled dialysis catheters in patients on haemodialysis. The retrospective study was conducted at the Department of Interventional Radiology, Shifa International Hospital, Islamabad, and comprised records of 100 consecutive subjects from a list of patients in whom tunnelled cuffed catheters were placed from February 2009 to January 2011 and were followed up for two years. Data was collected on a proforma from the hospital database and medical records of patients. SPSS 19 was used for statistical analysis. Of the total 122 catheters placed in 100 patients, 49 (40.16%) were lost to follow-up. Of the remaining 73 (59.83%) catheters, 38 (52%) had achieved their desired function, while 35 (48%) failed to achieve the target duration. Among the reasons of catheter failure, infection was the commonest at 13 (37.14%) with infection rate of 0.24 per 1000 catheter days. According to Kaplan Meier analysis, catheter survival rates at 60, 90 and 180 days were 89%, 77% and 64% respectively. Mean effective duration of catheter was 129 +/- 117 days. Tunnelled dialysis catheters can be safely used as vascular access till the maturation of fistula and may be an alternative to Arterio-Venous Fistula or graft for long-term vascular access if indicated.

  6. [Rotational stability of angiography catheters].

    Science.gov (United States)

    Schröder, J; Weber, M

    1992-10-01

    Rotatory stability is a parameter that reflects the ability of a catheter to transmit a rotation applied at the outer end to the catheter tip for the purpose of selective probing. A method for measuring the rotatory stability is described, and the results of rotatory stability measurements of 70 different commercially available catheters are reported. There is an almost linear correlation between the rotatory stability and the difference between the respective fourth power of the external and internal diameter or, approximately, to the fourth power of the external diameter for catheters without wire reinforcement. With the same cross-sectional dimensions, the rotatory stability of teflon, polyethylene, and nylon catheters has an approximate ratio of 1:2:4. Wire reinforcement increases rotatory stability by an average factor of about 3. For catheters of calibers 5 F and 6 F, a correlation between the rotatory stability and the weight of the reinforcing wire mesh is apparent.

  7. Atrial fibrillation ablation using a closed irrigation radiofrequency ablation catheter.

    Science.gov (United States)

    Golden, Keith; Mounsey, John Paul; Chung, Eugene; Roomiani, Pahresah; Morse, Michael Andew; Patel, Ankit; Gehi, Anil

    2012-05-01

    Catheter ablation is an effective therapy for symptomatic, medically refractory atrial fibrillation (AF). Open-irrigated radiofrequency (RF) ablation catheters produce transmural lesions at the cost of increased fluid delivery. In vivo models suggest closed-irrigated RF catheters create equivalent lesions, but clinical outcomes are limited. A cohort of 195 sequential patients with symptomatic AF underwent stepwise AF ablation (AFA) using a closed-irrigation ablation catheter. Recurrence of AF was monitored and outcomes were evaluated using Kaplan-Meier survival analysis and Cox proportional hazards models. Mean age was 59.0 years, 74.9% were male, 56.4% of patients were paroxysmal and mean duration of AF was 5.4 years. Patients had multiple comorbidities including hypertension (76.4%), tobacco abuse (42.1%), diabetes (17.4%), and obesity (mean body mass index 30.8). The median follow-up was 55.8 weeks. Overall event-free survival was 73.6% with one ablation and 77.4% after reablation (reablation rate was 8.7%). Median time to recurrence was 26.9 weeks. AF was more likely to recur in patients being treated with antiarrhythmic therapy at the time of last follow-up (recurrence rate 30.3% with antiarrhythmic drugs, 13.2% without antiarrhythmic drugs; hazard ratio [HR] 2.2, 95% confidence interval [CI] 1.1-4.4, P = 0.024) and in those with a history of AF greater than 2 years duration (HR 2.7, 95% CI 1.1-6.9, P = 0.038). Our study represents the largest cohort of patients receiving AFA with closed-irrigation ablation catheters. We demonstrate comparable outcomes to those previously reported in studies of open-irrigation ablation catheters. Given the theoretical benefits of a closed-irrigation system, a large head-to-head comparison using this catheter is warranted. ©2012, The Authors. Journal compilation ©2012 Wiley Periodicals, Inc.

  8. Open Surgical Insertion of Tenkchoff Straight Catheter Without Guide Wire

    Institute of Scientific and Technical Information of China (English)

    Shi-feng Yang; Wu-jun Xue; Ai-ping Yin; Li-yi Xie; Wan-hong Lu

    2013-01-01

    Objective To compare the clinical outcomes of open surgical peritoneal dialysiscatheter(PDC) insertion with guide wireand the outcomesof PDC insertion without guide wire.Methods Data of the patients receiving open surgical Tenkchoff straight catheter insertion in our department from January 2005 to January 2011 were retrospectively analyzed.The 117 patients in whom PDC insertion was conducted with the guidance of guide wire were enrolled into group A, and the 121 cases receiving PDC insertion without guide wire wereenrolled into group B.The incidences of post-operative complications (catheter obstruction,catheter displacement, bloody dialysate, and dialysate leakage), catheter survival, and patientsurvival rates were compared between the 2 groups.Results The baseline characteristics (gender, age, body mass index, prothrombin time,activated partialthromboplastin time,platelet count,serum creatinine,follow-up time,primarydiseases, and outcomes) of the 2 groups were comparable (allP>0.05). In post-operativecomplications, only the incidence of early bloody dialysate showed significant difference, being16.2% in groupA and 7.4% in group B (P=0.04). Catheter and patient survival rates werenot significantly different between the two groups. Overweight patientsshowed a higherincidence of catheter obstruction compared with normal weight patients [16.0% (4/25) vs. 3.3% (7/213),P=0.02], but no differencesin post-operative complications werefound among overweight patientsbetween the 2 groups.Conclusions Open surgical Tenkchoff straightcatheterinsertion without guide wire does not lead to higher risk of post-operative complications and catheter removal. It may be an alternativeoption when guide wire is not available.

  9. Comparison of the clinical effects between catheter exchange methods in geriatric patients with tunneled cuffed hemodialysis catheters

    Institute of Scientific and Technical Information of China (English)

    周参新

    2012-01-01

    Objective To compare the infection-free and overall survival between first and subsequent tunneled cuffed hemodialysis catheters in geriatric patients. Methods The study involved 57 geriatric patients [32 male,25 female; mean age(72.4±6.7) years]undergoing maintenance hemodialysis in our blood

  10. Preventing central venous catheter-related infection in a surgical intensive-care unit

    NARCIS (Netherlands)

    Bijma, R; Girbes, AR; Kleijer, DJ; Zwaveling, JH

    1999-01-01

    The cumulative effect of five measures (introduction of hand disinfection with alcohol, a new type of dressing, a one-bag system for parenteral nutrition, a new intravenous connection device, and surveillance by an infection control practitioner) on central venous catheter colonization and bacteremi

  11. Agile and Bright Intracardiac Catheters

    NARCIS (Netherlands)

    M. Pekař (Martin)

    2017-01-01

    markdownabstractIntracardiac imaging catheters represent unique instruments to diagnose and treat a diseased heart. While there are imminent advances in medical innovation, many of the commercially available imaging catheters are outdated. Some of them have been designed more than 20 years and

  12. Evaluation of percutaneous radiologic placement of peritoneal dialysis catheters: technical aspects, results, and complications

    Energy Technology Data Exchange (ETDEWEB)

    Hong, Hyun Pyo; Oh, Joo Hyeong; Yoon, Yub; Lee, Tae Won; Ihm, Chun Gyoo [Kyunghee University Hospital, seoul (Korea, Republic of)

    2001-01-01

    To evaluate the technical aspects, results and complications of the percutaneous radiologic placement of peritoneal dialysis catheters. Between December 1999 and April 2001, 26 peritoneal dialysis catheters were placed percutaneously in 26 consecutive patients by interventional radiologists. The patient group consisted of 16 men and ten women with a mean age of 55 (range, 30-77) years. The results and complications arising were reviewed, and the expected patency of the catheters was determined by means of Kaplan-Meier survival analysis. The technical success rate for catheter placement was 100% (26/26 patients). Severe local bleeding occurred in one patient due to by inferior epigastric artery puncture, and was treated by compression and electronic cautery. The duration of catheter implantation ranged from 1 to 510 days and the patency rate was 416{+-}45 days. Catheter malfunction occurred in four patients. In two, this was restored by manipulation in the intervention room, and in one, through the use of urokinase. In three patients, peritonitis occurred. Catheters were removed from four patients due to malfunction (n=2), peritonitis (n=1), and death (n=1). Percutaneous radiologic placement of a peritoneal dialysis catheter is a relatively simple procedure that reduces the complication rate and improves catheter patency.

  13. A Retrospective Study of Preferable Alternative Route to Right Internal Jugular Vein for Placing Tunneled Dialysis Catheters: Right External Jugular Vein versus Left Internal Jugular Vein.

    Directory of Open Access Journals (Sweden)

    Pei Wang

    Full Text Available Right internal jugular vein (IJV is a preferred access route for tunneled (cuffed dialysis catheters (TDCs, and both right external jugular vein (EJV and left IJV are alternative routes for patients in case the right IJV isn't available for TDC placement. This retrospective study aimed to determine if a disparity exists between the two alternative routes in hemodialysis patients in terms of outcomes of TDCs.49 hemodialysis patients who required TDCs through right EJV (n = 21 or left IJV (n = 28 as long-term vascular access were included in this study. The primary end point was cumulative catheter patency. Secondary end points include primary catheter patency, proportion of patients that never required urokinase and incidence of catheter-related bloodstream infections (CRBSI.A total of 20,870 catheter-days were evaluated and the median was 384 (interquartile range, 262-605 catheter-days. Fewer catheters were removed in the right EJV group than in the left IJV group (P = 0.007. Mean cumulative catheter patency was higher in the right EJV group compared with the left IJV group (P = 0.031. There was no significant difference between the two groups in the incidence of CRBSI, primary catheter patency or proportion of patients that never required urokinase use. Total indwell time of antecedent catheters was identified as an independent risk factor for cumulative catheter patency by Cox regression hazards test with an HR of 2.212 (95% CI, 1.363-3.588; p = 0.001.Right EJV might be superior to left IJV as an alternative insertion route for TDC placement in hemodialysis patients whose right IJVs are unavailable.

  14. Central Venous Catheter (Central Line)

    Science.gov (United States)

    ... connect a person with kidney failure to a hemodialysis machine that clears the body of wastes and extra fluid. ■ ■ As part of the procedure of inserting a right heart catheter (also known as a pulmonary artery or Swan ...

  15. Hydrodynamics of catheter biofilm formation

    CERN Document Server

    Sotolongo-Costa, Oscar; Rodriguez-Perez, Daniel; Martinez-Escobar, Sergio; Fernandez-Barbero, Antonio

    2009-01-01

    A hydrodynamic model is proposed to describe one of the most critical problems in intensive medical care units: the formation of biofilms inside central venous catheters. The incorporation of approximate solutions for the flow-limited diffusion equation leads to the conclusion that biofilms grow on the internal catheter wall due to the counter-stream diffusion of blood through a very thin layer close to the wall. This biological deposition is the first necessary step for the subsequent bacteria colonization.

  16. Prospective study of peripheral arterial catheter infection and comparison with concurrently sited central venous catheters.

    Science.gov (United States)

    Koh, David Boon Chai; Gowardman, John R; Rickard, Claire M; Robertson, Iain K; Brown, Andrew

    2008-02-01

    Peripheral arterial catheters are perceived as having low infective potential compared with other catheters and may be overlooked as a cause of catheter-related bloodstream infection. We aimed to measure colonization and rates of catheter-related bloodstream infection in arterial catheters, to investigate risk factors for arterial catheter colonization, and to compare arterial catheter infection rates with those in concurrently sited and managed central venous catheters. Prospective 24-month cohort study. Eight-bed combined general intensive care and high-dependency unit of a 350-bed Australian teaching hospital. Three hundred twenty-one arterial catheters in 252 adult and pediatric patients were observed for 1,082 catheter days, and 618 central venous catheters in 410 patients were observed for 4,040 catheter days. All catheters were inserted in, or presented to, the intensive care unit. Both arterial catheters and central venous catheters were inserted by trained personnel under aseptic conditions, and management was standardized. None. The incidence per 1,000 (95% confidence interval) catheter days of colonization (> or = 15 colonies) and catheter-related bloodstream infection was 15.7 (9.5-25.9) and 0.92 (0.13-6.44) for arterial catheters and 16.8 (13.3-21.3) and 2.23 (1.12-4.44) for central venous catheters. Arterial catheter colonization was not significantly different than that in central venous catheters (hazard ratio, 1.17; 95% confidence interval, 0.41-3.36; p = .77). Arterial catheter colonization increased with dwell time and was similar to central venous catheters over time. Femoral arterial catheters were colonized more often than radial arterial catheters (hazard ratio, 5.08; 95% confidence interval, 0.85, 30.3; p = .075), and colonization was significantly higher when the catheter was inserted in the operating theater or emergency department (hazard ratio, 4.45; 95% confidence interval, 1.42-13.9; p = .01) compared with the intensive care unit. The

  17. Longer duration of catheter patency, but similar infection rates with internal jugular vein versus iliac vein tunneled cuffed hemodialysis catheters: a single-center retrospective analysis.

    Science.gov (United States)

    Wang, Lihua; Wei, Fang; Jiang, Aili; Chen, Haiyan; Sun, Guijiang; Bi, Xueqing

    2015-10-01

    Although tunneled cuffed catheters (TCCs) are widely used in hemodialysis, little is known about their complications in elderly patients with hemodialysis. Furthermore, there is no report about which vessel access, either jugular or iliac vein, is superior for elderly patients requiring TCCs. In the present study, we reviewed the clinical parameters of 127 patients aged over 65 years with 207 new TCC placements and measured the incidence of catheter patency, infection, dysfunction, and survival of TCCs. We found that the average primary catheter patency was substantially shorter in iliac vein TCCs than in internal jugular vein TCCs (373 vs. 641 catheter-days). Patients with iliac vein TCCs underwent more frequent exchanges than those with internal jugular vein TCCs. Infection-free survival was similar for both groups (p = 0.748), but dysfunction-free survival was significantly poorer in iliac vein TCC group than that in internal jugular vein TCC group (p = 0.001). Age and previous catheter placement were the independent risk factors for TCCs survival. Taken together, our results suggested that iliac vein TCCs present an increased risk of dysfunction compared to internal jugular vein TCCs in elderly hemodialysis patients.

  18. A role for peripherally inserted central venous catheters in the prevention of catheter-related blood stream infections in patients with hematological malignancies.

    Science.gov (United States)

    Sakai, Toshiro; Kohda, Kyuhei; Konuma, Yuichi; Hiraoka, Yasuko; Ichikawa, Yukari; Ono, Kaoru; Horiguchi, Hiroto; Tatekoshi, Ayumi; Takada, Kouichi; Iyama, Satoshi; Kato, Junji

    2014-12-01

    Central venous catheter-related blood stream infections (CR-BSIs) are a serious complication in patients with hematological malignancies. However, it remains unclear whether there is a difference in the rate of CR-BSI associated with the conventional type of central venous catheters (cCVCs) and peripherally inserted CVCs (PICCs) in such patients. To address this question, we retrospectively investigated the incidence of CR-BSIs associated with PICCs versus cCVCs in patients with hematological malignancies. We used PICCs in all consecutive patients requiring CVC placement between February 2009 and February 2013. We compared the CR-BSI rate in patients with PICCs with that in patients with cCVCs treated between September 2006 and January 2009 (control group). Eighty-four patients received PICCs and 85 received cCVCs. The most common reason for removal due to catheter-related complications was CR-BSI. The CR-BSI rate in the PICC group was significantly lower than that in the cCVC group (PICCs: 1.23/1000 catheter days; cCVCs: 5.30/1000 catheter days; P Catheter-related complications other than CR-BSIs occurred at an extremely low rate in the PICC group. The median catheter-related complication-free survival duration was significantly longer in the PICC group than in the cCVC group. Our study shows that PICCs are useful in patients with hematological malignancies.

  19. Cumulant expansions for atmospheric flows

    CERN Document Server

    Ait-Chaalal, Farid; Meyer, Bettina; Marston, J B

    2015-01-01

    The equations governing atmospheric flows are nonlinear, and consequently the hierarchy of cumulant equations is not closed. But because atmospheric flows are inhomogeneous and anisotropic, the nonlinearity may manifests itself only weakly through interactions of mean fields with disturbances such as thermals or eddies. In such situations, truncations of the hierarchy of cumulant equations hold promise as a closure strategy. We review how truncations at second order can be used to model and elucidate the dynamics of turbulent atmospheric flows. Two examples are considered. First, we study the growth of a dry convective boundary layer, which is heated from below, leading to turbulent upward energy transport and growth of the boundary layer. We demonstrate that a quasilinear truncation of the equations of motion, in which interactions of disturbances among each other are neglected but interactions with mean fields are taken into account, can successfully capture the growth of the convective boundary layer. Seco...

  20. Electro-cumulation CNF project

    CERN Document Server

    Grishin, V G

    2000-01-01

    bound or free ion current within solid substances; non-plain symmetry; cumulation of the ion interaction. Experimental result: an Ice SuperPolarization. Cold nuclear fusion ? At http://www.shortway.to/to2084 . Keywords: ion, current, solid, symmetry, cumulation, cold nuclear fusion, polarization, depolarization, ionic conductor, superionic conductor, ice, crystal, strain, V-center, V-centre, doped crystal, interstitial impurity, intrinsic color center, high pressure technology, Bridgman, experiment, crowdion, dielectric, proton, layer, defect, lattice, dynamics, electromigration, mobility, muon catalysis, concentration, doping, dopant, conductivity, pycnonuclear reaction, permittivity, dielectric constant, point defects, interstitials, polarizability, imperfection, defect centers, glass, epitaxy, sodium hydroxide, metallic substrate, crystallization, point, tip, susceptibility, ferroelectric, ordering, force, correlation, collective, shift, distortion, coalescence, crowdions, electrolysis.

  1. Compensation for Unconstrained Catheter Shaft Motion in Cardiac Catheters

    Science.gov (United States)

    Degirmenci, Alperen; Loschak, Paul M.; Tschabrunn, Cory M.; Anter, Elad; Howe, Robert D.

    2016-01-01

    Cardiac catheterization with ultrasound (US) imaging catheters provides real time US imaging from within the heart, but manually navigating a four degree of freedom (DOF) imaging catheter is difficult and requires extensive training. Existing work has demonstrated robotic catheter steering in constrained bench top environments. Closed-loop control in an unconstrained setting, such as patient vasculature, remains a significant challenge due to friction, backlash, and physiological disturbances. In this paper we present a new method for closed-loop control of the catheter tip that can accurately and robustly steer 4-DOF cardiac catheters and other flexible manipulators despite these effects. The performance of the system is demonstrated in a vasculature phantom and an in vivo porcine animal model. During bench top studies the robotic system converged to the desired US imager pose with sub-millimeter and sub-degree-level accuracy. During animal trials the system achieved 2.0 mm and 0.65° accuracy. Accurate and robust robotic navigation of flexible manipulators will enable enhanced visualization and treatment during procedures. PMID:27525170

  2. Cumulative Paired φ-Entropy

    Directory of Open Access Journals (Sweden)

    Ingo Klein

    2016-07-01

    Full Text Available A new kind of entropy will be introduced which generalizes both the differential entropy and the cumulative (residual entropy. The generalization is twofold. First, we simultaneously define the entropy for cumulative distribution functions (cdfs and survivor functions (sfs, instead of defining it separately for densities, cdfs, or sfs. Secondly, we consider a general “entropy generating function” φ, the same way Burbea et al. (IEEE Trans. Inf. Theory 1982, 28, 489–495 and Liese et al. (Convex Statistical Distances; Teubner-Verlag, 1987 did in the context of φ-divergences. Combining the ideas of φ-entropy and cumulative entropy leads to the new “cumulative paired φ-entropy” ( C P E φ . This new entropy has already been discussed in at least four scientific disciplines, be it with certain modifications or simplifications. In the fuzzy set theory, for example, cumulative paired φ-entropies were defined for membership functions, whereas in uncertainty and reliability theories some variations of C P E φ were recently considered as measures of information. With a single exception, the discussions in the scientific disciplines appear to be held independently of each other. We consider C P E φ for continuous cdfs and show that C P E φ is rather a measure of dispersion than a measure of information. In the first place, this will be demonstrated by deriving an upper bound which is determined by the standard deviation and by solving the maximum entropy problem under the restriction of a fixed variance. Next, this paper specifically shows that C P E φ satisfies the axioms of a dispersion measure. The corresponding dispersion functional can easily be estimated by an L-estimator, containing all its known asymptotic properties. C P E φ is the basis for several related concepts like mutual φ-information, φ-correlation, and φ-regression, which generalize Gini correlation and Gini regression. In addition, linear rank tests for scale that

  3. Bacteriological Profile of Epidural Catheters

    Directory of Open Access Journals (Sweden)

    B. M. Sahay, Sanjot Dahake, D. K Mendiratta*,Vijayshree Deotale*,B. Premendran, P.S.Dhande, Pratibha Narang*

    2010-01-01

    Full Text Available The bacteriological profile of epidural catheters was studied in 88 patients. Skin swabs before catheterizationand before removal of catheter with their controls were cultured in TSB Medium. The catheter hub, theportion at the skin puncture site and at the tip were cultured in TSB Medium. The 1cm of the catheter bitjust before the tip was cultured in TGB medium for anaerobes.Both, the skin controls swabs and theanaerobic culture, were negative. From the remaining, 56 positive cultures were obtained. Staphylococcusepidermidis was the predominant organism in 52% followed by staphylococcus aureus 25%. The remaining23% was shared by Acinetobacter, Pseudomonas, Klebsiella, and E. coli. All the positive cultures fromskin prior to epidural catheterization had turned sterile by 48 hours, indicating continued bactericidal actionof the disinfectant. The likely source of positive skin cultures at 48 hours is hair follicles.The catheter tipculture was positive in 9 specimen, none of which resulted in the formation of epidural abscess. In 3 casesthe cultures of skin puncture site and the tip were identical indicating tracking-in of the organisms.

  4. Catheter-based photoacoustic endoscope

    Science.gov (United States)

    Yang, Joon-Mo; Li, Chiye; Chen, Ruimin; Zhou, Qifa; Shung, K. Kirk; Wang, Lihong V.

    2014-06-01

    We report a flexible shaft-based mechanical scanning photoacoustic endoscopy (PAE) system that can be potentially used for imaging the human gastrointestinal tract via the instrument channel of a clinical video endoscope. The development of such a catheter endoscope has been an important challenge to realize the technique's benefits in clinical settings. We successfully implemented a prototype PAE system that has a 3.2-mm diameter and 2.5-m long catheter section. As the instrument's flexible shaft and scanning tip are fully encapsulated in a plastic catheter, it easily fits within the 3.7-mm diameter instrument channel of a clinical video endoscope. Here, we demonstrate the intra-instrument channel workability and in vivo animal imaging capability of the PAE system.

  5. The Algebra of the Cumulative Percent Operation.

    Science.gov (United States)

    Berry, Andrew J.

    2002-01-01

    Discusses how to help students avoid some pervasive reasoning errors in solving cumulative percent problems. Discusses the meaning of ."%+b%." the additive inverse of ."%." and other useful applications. Emphasizes the operational aspect of the cumulative percent concept. (KHR)

  6. Adaptive strategies for cumulative cultural learning.

    Science.gov (United States)

    Ehn, Micael; Laland, Kevin

    2012-05-21

    The demographic and ecological success of our species is frequently attributed to our capacity for cumulative culture. However, it is not yet known how humans combine social and asocial learning to generate effective strategies for learning in a cumulative cultural context. Here we explore how cumulative culture influences the relative merits of various pure and conditional learning strategies, including pure asocial and social learning, critical social learning, conditional social learning and individual refiner strategies. We replicate the Rogers' paradox in the cumulative setting. However, our analysis suggests that strategies that resolved Rogers' paradox in a non-cumulative setting may not necessarily evolve in a cumulative setting, thus different strategies will optimize cumulative and non-cumulative cultural learning.

  7. "Buddha's Light" of Cumulative Particles

    CERN Document Server

    Kopeliovich, Vladimir B; Potashnikova, Irina K

    2014-01-01

    We show analytically that in the cumulative particles production off nuclei multiple interactions lead to a glory-like backward focusing effect. Employing the small phase space method we arrived at a characteristic angular dependence of the production cross section $d\\sigma \\sim 1/ \\sqrt {\\pi - \\theta}$ near the strictly backward direction. This effect takes place for any number $n\\geq 3 $ of interactions of rescattered particle, either elastic or inelastic (with resonance excitations in intermediate states), when the final particle is produced near corresponding kinematical boundary. Such a behaviour of the cross section near the backward direction is in qualitative agreement with some of available data.

  8. A Resource Cost Aware Cumulative

    Science.gov (United States)

    Simonis, Helmut; Hadzic, Tarik

    We motivate and introduce an extension of the well-known cumulative constraint which deals with time and volume dependent cost of resources. Our research is primarily interested in scheduling problems under time and volume variable electricity costs, but the constraint equally applies to manpower scheduling when hourly rates differ over time and/or extra personnel incur higher hourly rates. We present a number of possible lower bounds on the cost, including a min-cost flow, different LP and MIP models, as well as greedy algorithms, and provide a theoretical and experimental comparison of the different methods.

  9. Chronic peritoneal dialysis catheters in children: a fifteen-year experience of the Italian Registry of Pediatric Chronic Peritoneal Dialysis.

    Science.gov (United States)

    Rinaldi, Stefano; Sera, Francesco; Verrina, Enrico; Edefonti, Alberto; Gianoglio, Bruno; Perfumo, Francesco; Sorino, Palma; Zacchello, Graziella; Cutaia, Ignazio; Lavoratti, Giancarlo; Leozappa, Giovanna; Pecoraro, Carmine; Rizzoni, Gianfranco

    2004-01-01

    To analyze data on 503 chronic peritoneal dialysis (CPD) catheters implanted between 1986 and 2000 in pediatric patients enrolled in the Italian Registry of Pediatric Chronic Peritoneal Dialysis (the Registry), comparing three different time periods: 1986-1990, 1991-1995, and 1996-2000. Retrospective study. 23 dialysis centers participating in the Registry. Data were collected from questionnaires filled in every year. The information for each peritoneal catheter included type, site and technique of insertion, exit-site orientation, exit-site care, complications, survival, and reason for removal. 503 catheters were implanted in 363 pediatric patients aged younger than 15 years at the start of CPD: 97 catheters in patients under 2 years of age, 67 in patients aged 2-5 years, and 339 in patients over 5 years of age. Mean patient age at onset of CPD was 8.0 +/- 5.1 years. All catheters were surgically implanted and omentectomy was performed in 82.4% of cases. The catheters used were Tenckhoff [468 (93.0%): 443 double cuff, 25 single cuff] and double-cuffed Valli [35 (7.0%)]. The entry site was in the midline in 153 cases (30.4%) and paramedian in 350 (69.6%). During 9048 dialysis-months we observed 451 catheter-related complications, yielding an incidence of 1 episode/20.1 CPD-months: 330 catheter infections (exit-site and/or tunnel infections), 26 leakages, 26 dislocations, 24 obstructions, 22 cuff extrusions, 6 hemoperitoneums, 17 others. 171 catheters were removed due to catheter-related causes; exit-site and/or tunnel infections were the main cause for removal (75.4%), followed by obstruction, dislocation, outer-cuff extrusion, and leakage. Younger children ( 5 years hazard ratio 0.8, 95%CI 0.5-1.1. In this survey, we observed better catheter survival in comparison with data reported by the Registry in 1998. Catheter survival improved especially in younger children (< 2 years), a group that previously had a decreased catheter survival rate compared to older age

  10. 21 CFR 870.1280 - Steerable catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter. 870.1280 Section 870.1280 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1280 Steerable catheter. (a) Identification. A steerable catheter is...

  11. 21 CFR 882.4100 - Ventricular catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Ventricular catheter. 882.4100 Section 882.4100...) MEDICAL DEVICES NEUROLOGICAL DEVICES Neurological Surgical Devices § 882.4100 Ventricular catheter. (a) Identification. A ventricular catheter is a device used to gain access to the cavities of the brain for...

  12. Hemodialysis Tunneled Catheter-Related Infections

    Science.gov (United States)

    Miller, Lisa M.; Clark, Edward; Dipchand, Christine; Hiremath, Swapnil; Kappel, Joanne; Kiaii, Mercedeh; Lok, Charmaine; Luscombe, Rick; Moist, Louise; Oliver, Matthew; MacRae, Jennifer

    2016-01-01

    Catheter-related bloodstream infections, exit-site infections, and tunnel infections are common complications related to hemodialysis central venous catheter use. The various definitions of catheter-related infections are reviewed, and various preventive strategies are discussed. Treatment options, for both empiric and definitive infections, including antibiotic locks and systemic antibiotics, are reviewed.

  13. A paradox of cumulative culture.

    Science.gov (United States)

    Kobayashi, Yutaka; Wakano, Joe Yuichiro; Ohtsuki, Hisashi

    2015-08-21

    Culture can grow cumulatively if socially learnt behaviors are improved by individual learning before being passed on to the next generation. Previous authors showed that this kind of learning strategy is unlikely to be evolutionarily stable in the presence of a trade-off between learning and reproduction. This is because culture is a public good that is freely exploited by any member of the population in their model (cultural social dilemma). In this paper, we investigate the effect of vertical transmission (transmission from parents to offspring), which decreases the publicness of culture, on the evolution of cumulative culture in both infinite and finite population models. In the infinite population model, we confirm that culture accumulates largely as long as transmission is purely vertical. It turns out, however, that introduction of even slight oblique transmission drastically reduces the equilibrium level of culture. Even more surprisingly, if the population size is finite, culture hardly accumulates even under purely vertical transmission. This occurs because stochastic extinction due to random genetic drift prevents a learning strategy from accumulating enough culture. Overall, our theoretical results suggest that introducing vertical transmission alone does not really help solve the cultural social dilemma problem. Copyright © 2015 Elsevier Ltd. All rights reserved.

  14. Effectiveness of different central venous catheters for catheter-related infections: a network meta-analysis.

    Science.gov (United States)

    Wang, H; Huang, T; Jing, J; Jin, J; Wang, P; Yang, M; Cui, W; Zheng, Y; Shen, H

    2010-09-01

    We aimed to compare the effectiveness of various catheters for prevention of catheter-related infection and to evaluate whether specific catheters are superior to others for reducing catheter-related infections. We identified randomised, controlled trials that compared different types of central venous catheter (CVC), evaluating catheter-related infections in a systematic search of articles published from January 1996 to November 2009 via Medline, Embase, Web of Science, and the Cochrane Central Register of Controlled Trials. Network meta-analysis with a mixed treatment comparison method using Bayesian Markov Chain Monte Carlo simulation was used to combine direct within-trial, between-treatment comparisons with indirect trial evidence. Forty-eight clinical trials (12 828 CVCs) investigating 10 intervention catheters contributed to the analyses. For prevention of CVC colonisation, adjusted silver iontophoretic catheters (odds ratio: 0.58; 95% confidence interval: 0.33-0.95), chlorhexidine and silver sulfadiazine catheters (0.49; 0.36-0.64), chlorhexidine and silver sulfadiazine blue plus catheters (0.37; 0.17-0.69), minocycline-rifampicin catheters (0.28; 0.17-0.43) and miconazole-rifampicin catheters (0.11; 0.02-0.33) were associated with a significantly lower rate of catheter colonisation compared with standard catheters. For prevention of CRBSI, adjusted heparin-bonded catheters (0.20; 0.06-0.44) and minocycline-rifampicin catheters (0.18; 0.08-0.34) were associated with a significantly lower rate of CRBSI with standard catheters. Rifampicin-based impregnated catheters seem to be better for prevention of catheter-related infection compared with the other catheters.

  15. Transhepatic venous catheters for hemodialysis

    Directory of Open Access Journals (Sweden)

    Mohamed El Gharib

    2014-06-01

    Conclusion: Based on our findings, transhepatic hemodialysis catheters have proven to achieve good long-term functionality. A high level of maintenance is required to preserve patency, although this approach provides remarkably durable access for patients who have otherwise exhausted access options.

  16. Totally implantable catheter embolism: two related cases

    Directory of Open Access Journals (Sweden)

    Rodrigo Chaves Ribeiro

    Full Text Available CONTEXT AND OBJECTIVE: Long-term totally implantable catheters (e.g. Port-a-Cath® are frequently used for long-term venous access in children with cancer. The use of this type of catheter is associated with complications such as infection, extrusion, extravasation and thrombosis. Embolism of catheter fragments is a rare complication, but has potential for morbidity. The aim here was to report on two cases in which embolism of fragments of a long-term totally implantable catheter occurred. DESIGN AND SETTING: Case series study at Hospital do Servidor Público Estadual, São Paulo. METHODS: Retrospective review of catheter embolism in oncological pediatric patients with long-term totally implantable catheters. RESULTS: The first patient was a 3-year-old girl diagnosed with stage IV Wilms' tumor. Treatment was started with the introduction of a totally implantable catheter through the subclavian vein. At the time of removal, it was realized that the catheter had fractured inside the heart. An endovascular procedure was necessary to remove the fragment. The second case was a boy diagnosed with stage II Wilms' tumor at the age of two years. At the time of removal, it was noticed that the catheter had disconnected from the reservoir and an endovascular procedure was also necessary to remove the embolized catheter. CONCLUSION: Embolism of fragments of totally implantable catheters is a rare complication that needs to be recognized even in asymptomatic patients.

  17. [Comparative study of PTFE grafts in forearm vs cuffed permanent catheters].

    Science.gov (United States)

    Moyano, M J; Salgueira, M; Aresté, N; Escalera, B; del Toro, N; Jiménez-Víbora, E; Martínez-Puerto, A I; Molas, J R; Palma, A

    2006-01-01

    As is universally accepted the best form of permanent vascular access for haemodialysis is the native arteriovenous fistula. A second and third options are the politetrafluoroethylene (PTFE) AV grafts and the cuffed, tunneled, internal catheters. The overall performance and complications of catheters is clearly inferior to AV fistula. There are not many studies that compare permanent catheters to grafts in terms of functionality, survival and complications. We analyzed 81 vascular accesses carried out from october 99 to december 03 in 59 patients and during a follow-up period of 35 months. Two groups were considered. Group 1, catheters (n 42) and group 2, grafts (n 39). Clinical aspects, comorbidity index (Wright and Kanh), dialysis dose and complications and survival of the access were registered. Both groups were similar in age, sex, time on haemodialysis, number of previous accesses and hospitalization days. Cardiovascular morbidity and comorbidity index were significantly higher in patients with catheter. While blood flow during dialysis was higher in grafts both groups showed no significant differences in parameters of efficacy of dialysis (Kt/V, TAC BUN and PCRn). Serum albumin was lower in patients with catheter. The number of accesses that failed was higher in the graft group being thrombosis the main complication followed by infection. Kaplan-Meier curves showed better accumulated survival of permanent catheters versus grafts (61,4% vs 9,8% at 35 months). The most frequent complication of catheter was infection while in the case of grafts it was thrombosis followed by infection. Although they were placed in patients with higher comorbidity, cuffed, tunneled catheters showed less number of complications and better survival than PTFE grafts in our patients in haemodialysis. The main cause of failure of both vascular access was thrombosis followed by infection. The dose of dialysis obtained was no different in both groups. Cuffed, tunneled permanent catheters

  18. Percutaneous versus laparoscopic placement of peritoneal dialysis catheters: Simplicity and favorable outcome

    Directory of Open Access Journals (Sweden)

    Abdulla K Al-Hwiesh

    2014-01-01

    Full Text Available Implantation of peritoneal dialysis (PD catheters via the laparoscopic technique is expanding, but none of the studies concerning this technique have compared its outcome with the percutaneous insertion done by the nephrologist. We compared the technical survival and outcome of 52 PD catheters placed in 43 patients with end-stage renal disease (ESRD in our center from March 2006 to October 2007. Of these, 27 PD catheters were inserted percutaneously by a nephrologist (group 1 and 25 were placed by a surgeon using the conventional laparoscopic technique (group 2. Very obese patients, those with previous abdominal surgery, and those who refused local anesthesia were excluded from the study. All catheters were evaluated for mechanical and infectious complications and the overall technique survival was analyzed. The incidence of complications in PD catheters did not largely differ between the two groups. Early catheter-related infection episodes (within two weeks of catheter placement occurred in three of 22 (13.6% patients in group 1, versus three of 21 (14.3% patients in group 2 (P >0.05. The incidence of exit site leak was higher in group 2 (19.0% compared to (4.5% group 1 (P 0.05. We conclude that in our study, the percutaneous bedside placements of PD catheters done by nephrologists were comparable with the laparoscopic insertions performed by surgeons where the high-risk patients were avoided, and the former provided a safer and more reliable access that allowed a rapid initiation of PD.

  19. Comparison of heparin to citrate as a catheter locking solution for non-tunneled central venous hemodialysis catheters in patients requiring renal replacement therapy for acute renal failure (VERROU-REA study): study protocol for a randomized controlled trial.

    Science.gov (United States)

    Bruyère, Rémi; Soudry-Faure, Agnès; Capellier, Gilles; Binquet, Christine; Nadji, Abdelouaid; Torner, Stephane; Blasco, Gilles; Yannaraki, Maria; Barbar, Saber Davide; Quenot, Jean-Pierre

    2014-11-19

    The incidence of acute kidney injury (AKI) is estimated at 10 to 20% in patients admitted to intensive care units (ICU) and often requires renal replacement therapy (RRT). ICU mortality in AKI patients can exceed 50%. Venous catheters are the preferred vascular access method for AKI patients requiring RRT, but carry a risk of catheter thrombosis or infection. Catheter lock solutions are commonly used to prevent such complications. Heparin and citrate locks are both widely used for tunneled, long-term catheters, but few studies have compared citrate versus heparin for patients with short-term, non-tunneled catheters. We aim to compare citrate 4% catheter lock solution versus heparin in terms of event-free survival of the first non-tunneled hemodialysis catheter inserted in ICU patients with AKI requiring RRT. Secondary objectives are the rate of fibrinolysis, incidence of catheter thrombosis and catheter-related infection per 1,000 catheter days, length of stay in ICU and in-hospital and 28-day mortality. The VERROU-REA study is a randomized, prospective, multicenter, double-blind, parallel-group, controlled superiority study carried out in the medical, surgical and nephrological ICUs of two large university hospitals in eastern France. A catheter lock solution composed of trisodium citrate at 4% will be compared to unfractionated heparin at a concentration of 5,000 IU/mL. All consecutive adult patients with AKI requiring extracorporeal RRT, and in whom a first non-tunneled catheter is to be inserted by the jugular or femoral approach, will be eligible. Catheters inserted by the subclavian approach, patients with acute liver failure, thrombopenia or contraindication to systemic anticoagulation will be excluded. Patients will be followed up daily in accordance with standard practices for RRT until death or discharge. Data is scarce regarding the use of non-tunneled catheters in the ICU setting in patients with AKI. This study will provide an evidence base for

  20. Long-term outcomes of arteriovenous thigh grafts in hemodialysis patients: a comparison with tunneled dialysis catheters.

    Science.gov (United States)

    Ong, Song; Barker-Finkel, Jill; Allon, Michael

    2013-05-01

    Arteriovenous thigh grafts are a potential vascular access option in hemodialysis patients who have exhausted all upper-limb sites. This study compared the outcomes of thigh grafts with outcomes obtained with dialysis catheters. A prospective vascular access database was queried to identify 209 thigh grafts placed from January 1, 2003, to June 30, 2011. The following were calculated: secondary graft survival (from graft creation to permanent failure), assisted primary graft survival (from graft creation to first thrombosis), and infection-free graft survival (from graft creation to first graft infection). Graft outcomes were compared with those observed with 472 tunneled internal jugular dialysis catheters. The median duration of patient follow-up was 340 days for grafts and 91 days for catheters. The surgical technical failure rate of thigh grafts was 8.1% and was higher in patients with vascular disease (hazard ratio [HR], 2.94; 95% confidence interval [CI], 1.07-8.04; P=0.03). Secondary and assisted primary graft survival rates at 1, 2, and 5 years were 62%, 54%, and 38% and 38%, 27%, and 17%, respectively. Infection-free graft survival rates at 1, 2, and 5 years were 79%, 73%, and 61%. Secondary survival was much worse for dialysis catheters than thigh grafts (HR, 4.44; 95% CI, 3.65-5.22; Pcatheters than for thigh grafts (HR, 3.77; 95% CI, 2.80-4.82; Pdialysis catheters.

  1. Outcome of radiologically placed tunneled haemodialysis catheters.

    Science.gov (United States)

    Sayani, Raza; Anwar, Muhammad; Tanveer-ul-Haq; Al-Qamari, Nauman; Bilal, Muhammad Asif

    2013-12-01

    To study the outcome of radiologically placed double lumen tunneled haemodialysis catheters for the management of renal failure. Case series. Interventional Suite of Radiology Department at the Aga Khan University Hospital, Karachi, from April 2010 to June 2011. All consecutive patients who were referred to the department of radiology by the nephrologists for double lumen tunneled haemodialysis catheter (Permacath) placement during the study period were included. Patients with septicemia, those for whom follow-up was not available, those coming for catheter exchange or who died due to a noncatheter related condition were excluded. A radio-opaque, soft silicone double lumen catheter was inserted through a subcutaneous tunnel created over the anterior chest wall. The catheter tip was placed in the right atrium via the internal jugular vein. Ultrasound guidance was used for initial venous puncture. The rest of the procedure was carried out under fluoroscopic guidance. Technical success, catheter related bacteremia rates, adequacy of dialysis, patency, and adverse events were analyzed. Overall 88 tunneled haemodialysis catheters were placed in 87 patients. Patients were followed-up for duration of 1 - 307 days with mean follow-up period of 4 months. Immediate technical success was 100%. The procedural complication rate was 5.6% (5 catheters). Eight patients died during the study period, seven from causes unrelated to the procedure. One patient died due to septicemia secondary to catheter related infection. Of the remaining 69 patients, 50 (72.4%) predominantly had uneventful course during the study period. Twelve patients developed infection (17.3%); two were successfully treated conservatively while in 10 patients catheter had to be removed. Seven catheters (10.1%) failed due to mechanical problems. In 3 patients the internal jugular veins got partially thrombosed. One catheter was accidentally damaged in the ward and had to be removed. Radiological guided tunneled

  2. Untangling of knotted urethral catheters

    Energy Technology Data Exchange (ETDEWEB)

    Sambrook, Andrew J. [Aberdeen Royal Infirmary, Department of Radiology, Aberdeen (United Kingdom); Todd, Alistair [Raigmore Hospital, Inverness (United Kingdom)

    2007-04-15

    Intravesical catheter knotting during micturating cystourethrography is a rare but recognized complication of the procedure. We were able to untangle a knot utilizing a fluoroscopically guided vascular guidewire. Following this success, a small study was performed using a model. Various types of guidewires and techniques were tested for different diameters of knots in order to predict the likelihood of success in this type of situation. (orig.)

  3. Untangling of knotted urethral catheters.

    Science.gov (United States)

    Sambrook, Andrew J; Todd, Alistair

    2007-04-01

    Intravesical catheter knotting during micturating cystourethrography is a rare but recognized complication of the procedure. We were able to untangle a knot utilizing a fluoroscopically guided vascular guidewire. Following this success, a small study was performed using a model. Various types of guidewires and techniques were tested for different diameters of knots in order to predict the likelihood of success in this type of situation.

  4. The stuck catheter: a hazardous twist to the meaning of permanent catheters.

    Science.gov (United States)

    Vellanki, Venkat Sainaresh; Watson, Diane; Rajan, Dheeraj K; Bhola, Cynthia B; Lok, Charmaine E

    2015-01-01

    Permanent central venous catheter use is associated with significant complications that often require their timely removal. An uncommon complication is resistant removal of the catheter due to adherence of the catheter to the vessel wall. This occasionally mandates invasive interventions for removal. The aim of this study is to describe the occurrence of this "stuck catheter" phenomenon and its consequences. A retrospective review of all the removed tunneled hemodialysis catheters from July 2005 to December 2014 at a single academic-based hemodialysis center to determine the incidence of stuck catheters. Data were retrieved from a prospectively maintained computerized vascular access database and verified manually against patient charts. In our retrospective review of tunneled hemodialysis catheters spanning close to a decade, we found that 19 (0.92%) of catheters were retained, requiring endovascular intervention or open sternotomy. Of these, three could not be removed, with one patient succumbing to catheter-related infection. Longer catheter vintage appeared to be associated with 'stuck catheter'. Retention of tunneled central venous catheters is a rare but important complication of prolonged tunneled catheter use that nephrologists should be aware of. Endoluminal balloon dilatation procedures are the initial approach, but surgical intervention may be necessary.

  5. Optimization of dialysis catheter function.

    Science.gov (United States)

    Gallieni, Maurizio; Giordano, Antonino; Rossi, Umberto; Cariati, Maurizio

    2016-03-01

    Central venous catheters (CVCs) are essential in the management of hemodialysis patients, but they also carry unintended negative consequences and in particular thrombosis and infection, adversely affecting patient morbidity and mortality. This review will focus on the etiology, prevention, and management of CVC-related dysfunction, which is mainly associated with inadequate blood flow. CVC dysfunction is a major cause of inadequate depuration. Thrombus, intraluminal and extrinsic, as well as fibrous connective tissue sheath (traditionally indicated as fibrin sheath) formation play a central role in establishing CVC dysfunction. Thrombolysis with urokinase or recombinant tissue plasminogen activator (rTPA) can be undertaken in the dialysis unit, restoring adequate blood flow in most patients, preserving the existing catheter, and avoiding an interventional procedure. If thrombolytics fail, mainly because of the presence of fibrous connective tissue sheath, catheter exchange with fibrin sheath disruption may be successful and preserve the venous access site. Prevention of CVC dysfunction is important for containing costly pharmacologic and interventional treatments, which also affect patients' quality of life. Prevention is based on the use of anticoagulant and/or thrombolytic CVC locks, which are only partially effective. Chronic oral anticoagulation with warfarin has also been proposed, but its use for this indication is controversial and its overall risk-benefit profile has not been clearly established.

  6. [Survival and complication rate of central venous catheters in newborns].

    Science.gov (United States)

    García, Heladia Josefa; Torres-Yáñez, Héctor Leonardo

    2015-01-01

    Introducción: los catéteres venosos centrales (CVC) son de gran utilidad en la práctica médica actual; sin embargo, no están exentos de riesgos, lo que incrementa la morbilidad y mortalidad, especialmente en los recién nacidos (RN). El objetivo fue registrar la frecuencia de complicaciones de los CVC y su duración en RN en una unidad de cuidados intensivos neonatales (UCIN) de tercer nivel. Métodos: se realizó un estudio observacional descriptivo, prolectivo en la UCIN del Hospital de Pediatría del Centro Médico Nacional Siglo XXI. Se registraron variables demográficas, perinatales y del CVC. Resultados: se incluyeron 123 RN a quienes se les colocaron 152 CVC. La técnica más usada para la inserción del CVC fue la punción (percutánea o subclavia) en 56.6 % (n = 86). En 48.7 % (n = 74) de los CVC se presentó alguna complicación. Las más frecuentes fueron colonización en 32.4 % (n = 24) y bacteriemia relacionada con CVC en 27 % (n = 20). La probabilidad de duración de los CVC libres de complicaciones fue de 93.4 % a los 10 días y de 91.4 % a los 17 días. Los catéteres venosos no centrales tuvieron menor probabilidad de duración. Conclusión: la mayoría de las complicaciones de los CVC se presentaron en las primeras dos semanas de haber sido instalados. Las complicaciones infecciosas fueron las más frecuentes.

  7. Infections associated with the central venous catheters.

    Science.gov (United States)

    Drasković, Biljana; Fabri, Izabella; Benka, Anna Uram; Rakić, Goran

    2014-01-01

    Central venous catheters are of an essential importance to critically ill patients who require long-term venous access for various purposes. Their use made the treatment much easier, but still they are not harmless and are prone to numerous complications. Catheter infections represent the most significant complication in their use. The frequency of infections varies in different patient care settings, but their appearance mostly depends on the patient's health condition, catheter insertion time, localization of the catheter and type of the used catheter. Since they are one of the leading causes of nosocomial infections and related to significant number of morbidity and mortality in intensive care units, it is very important that maximal aseptic precautions are taken during the insertion and the maintenance period. Prevention of infection of the central venous catheters demands several measures that should be applied routinely.

  8. Position Control of Motion Compensation Cardiac Catheters

    Science.gov (United States)

    Kesner, Samuel B.; Howe, Robert D.

    2011-01-01

    Robotic catheters have the potential to revolutionize cardiac surgery by enabling minimally invasive structural repairs within the beating heart. This paper presents an actuated catheter system that compensates for the fast motion of cardiac tissue using 3D ultrasound image guidance. We describe the design and operation of the mechanical drive system and catheter module and analyze the catheter performance limitations of friction and backlash in detail. To mitigate these limitations, we propose and evaluate mechanical and control system compensation methods, including inverse and model-based backlash compensation, to improve the system performance. Finally, in vivo results are presented that demonstrate that the catheter can track the cardiac tissue motion with less than 1 mm RMS error. The ultimate goal of this research is to create a fast and dexterous robotic catheter system that can perform surgery on the delicate structures inside of the beating heart. PMID:21874124

  9. A case of misplaced permacath dialysis catheter

    Directory of Open Access Journals (Sweden)

    Mohammed Arshad Ali

    2015-01-01

    Full Text Available Central venous placement using ultrasound has significantly reduced the complications associated with blind puncture. The central venous catheter can still get misplaced if it follows an anomalous route after appropriate puncture of desired vessel. We report a case of misplaced dialysis catheter into the accessory hemiazygos vein which resulted in a large hemothorax, and we recommend the routine use of a fluoroscope for placement of dialysis catheters so as to avoid serious complications.

  10. Impact of different catheter lock strategies on bacterial colonization of permanent central venous hemodialysis catheters.

    Science.gov (United States)

    Erb, Stefan; Widmer, Andreas F; Tschudin-Sutter, Sarah; Neff, Ursula; Fischer, Manuela; Dickenmann, Michael; Grosse, Philipp

    2013-12-01

    Thirty-nine hemodialysis patients with permanent central venous catheters were analyzed for bacterial catheter colonization comparing different catheter-lock strategies. The closed needleless Tego connector with sodium chloride lock solution was significantly more frequently colonized with bacteria than the standard catheter caps with antimicrobially active citrate lock solution (odds ratio, 0.22 [95% confidence interval, 0.07-0.71]; P = .011).

  11. Extensions and Applications of the Cox-Aalen Survival Model

    DEFF Research Database (Denmark)

    Scheike, Thomas H.; Zhang, Mei-Jie

    2003-01-01

    Aalen additive risk model; competing risk; counting processes; Cox model; cumulative incidence function; goodness of fit; prediction of survival probability; time-varying effects......Aalen additive risk model; competing risk; counting processes; Cox model; cumulative incidence function; goodness of fit; prediction of survival probability; time-varying effects...

  12. Cumulative human impacts on marine predators

    DEFF Research Database (Denmark)

    Maxwell, Sara M; Hazen, Elliott L; Bograd, Steven J

    2013-01-01

    Stressors associated with human activities interact in complex ways to affect marine ecosystems, yet we lack spatially explicit assessments of cumulative impacts on ecologically and economically key components such as marine predators. Here we develop a metric of cumulative utilization and impact...

  13. Erroneous laboratory values obtained from central catheters.

    Science.gov (United States)

    Johnston, J B; Messina, M

    1991-01-01

    Serious analytic errors in potassium measurements have been identified in blood specimens obtained from newly inserted central catheters. Erroneous elevated readings have been related to interactions of chemistry analyzer electrodes and substances fixed to external and intraluminal walls of the central catheter. Anecdotal summaries of this phenomenon are presented to enable the nurse to recognize potential problems when sampling blood from central catheters. Studies were performed to determine the amount of flush necessary to clear the catheter of interfering residue. To eliminate this potentially hazardous occurrence, recommended flush volumes, nursing implications, and actions are described.

  14. Malposition of catheters during voiding cystourethrography

    Energy Technology Data Exchange (ETDEWEB)

    Rathaus, V.; Konen, O.; Shapiro, M. [Dept. of Diagnostic Imaging Sapir Medical Center, Kfar-Saba and Sackler Medical School, Tel Aviv University (Israel); Grunebaum, M. [Veteran Pediatric Radiologist, Kfar Saba (Israel)

    2001-04-01

    The aim of this study was to report catheter malposition during voiding cystourethrography. Eight hundred forty-three voiding cystourethrography (265 males and 578 females, aged 1 week to 12 years, mean age 2 years) were performed during a period of 4 years. The conventional standard procedure was applied. In 3 cases with passed history of urinary tract infection the catheter entered directly into the ureter. In all these cases the uretero-vesical reflux was present on the same side where the catheter entered. It appears that insertion of a catheter into the ureter is possible only in the presence of an anomaly or pathology at the vesicoureteric junction. (orig.)

  15. Catheter ablation - new developments in robotics.

    Science.gov (United States)

    Chun, K R Julian; Schmidt, Boris; Köktürk, Bülent; Tilz, Roland; Fürnkranz, Alexander; Konstantinidou, Melanie; Wissner, Erik; Metzner, Andreas; Ouyang, Feifan; Kuck, Karl-Heinz

    2008-12-01

    Catheter ablation has become the curative treatment modality for various arrhythmias. Extending the indications for catheter ablation from simple supraventricular tachycardias to complex arrhythmias such as ventricular tachycardia or atrial fibrillation, the investigator faces prolonged procedure times, fluoroscopy exposure and the need for stable and reproducible catheter movement. Recently, remote-controlled robotic catheter ablation has emerged as a novel ablation concept to meet these requirements. This review describes the two available robotic ablation systems and summarizes their clinical applications and current human experience.

  16. Encrusted and incarcerated urinary bladder catheter: what are the ...

    African Journals Online (AJOL)

    2010-11-25

    Nov 25, 2010 ... another technique of dealing with a stuck and encrustated catheter, via direct crushing of the encrustations ... During the last change of catheter, it was found to be ... catheter is a complicated problem due to the resistance.

  17. Different outcomes of peritoneal catheter percutaneous placement by nephrologists using a trocar versus the Seldinger technique: the experience of two Brazilian centers.

    Science.gov (United States)

    Ponce, Daniela; Banin, Vanessa B; Bueloni, Tricya Nunes; Barretti, Pasqual; Caramori, Jacqueline; Balbi, André Luís

    2014-10-01

    A good catheter implantation technique is important to allow effective peritoneal access function and long-term technique survival. Studies regarding results obtained by nephrologists in comparison with different techniques have been limited. The aim of this study was to investigate the rate of early catheter-related complications and catheter survival in two Brazilian centers, according to two different percutaneous methods of catheter implantation performed by nephrologist team. Adult incident patients recruited from January 2006 to July 2013 having undergone first peritoneal dialysis (PD) catheter implantation were included in the analysis. Mechanical and infectious early complication rates were defined as time to the first event occurring up to 3 months. Four hundred and forty-five consecutive Tenckhoff catheters were implanted by nephrologist team percutaneously after antibiotic prophylaxis in an operating room: trocar was used in 349 (78.4 %) and Seldinger technique (ST) in 99 (21.6 %). The ST was significantly associated with a lower rate of leak (16.3 vs 3 %, p = 0.03) and outflow failure due to tip catheter migration (22.6 vs 10.1 %, p = 0.04), while early infectious complication rates were similar between the two groups (p = 0.59). Long-term catheter survival was higher in Seldinger group (log-rank, p = 0.031). By Cox multivariate analysis, adjusted for age, sex, and diabetes, the ST remained independently associated with better catheter survival [HR 0.681 (0.462-0.910), p = 0.04]. As conclusion, our experience showed better PD outcomes with the ST than trocar method of catheter implantation by nephrologist.

  18. Nonlinear cumulative damage model for multiaxial fatigue

    Institute of Scientific and Technical Information of China (English)

    SHANG De-guang; SUN Guo-qin; DENG Jing; YAN Chu-liang

    2006-01-01

    On the basis of the continuum fatigue damage theory,a nonlinear uniaxial fatigue cumulative damage model is first proposed.In order to describe multiaxial fatigue damage characteristics,a nonlinear multiaxial fatigue cumulative damage model is developed based on the critical plane approach,The proposed model can consider the multiaxial fatigue limit,mean hydrostatic pressure and the unseparated characteristic for the damage variables and loading parameters.The recurrence formula of fatigue damage model was derived under multilevel loading,which is used to predict multiaxial fatigue life.The results showed that the proposed nonlinear multiaxial fatigue cumulative damage model is better than Miner's rule.

  19. The efficacy of noble metal alloy urinary catheters in reducing catheter-associated urinary tract infection

    Directory of Open Access Journals (Sweden)

    Alanood Ahmed Aljohi

    2016-01-01

    Results: A 90% relative risk reduction in the rate of CAUTI was observed with the noble metal alloy catheter compared to the standard catheter (10 vs. 1 cases, P = 0.006. When considering both catheter-associated asymptomatic bacteriuria and CAUTI, the relative risk reduction was 83% (12 vs. 2 cases, P = 0.005. In addition to CAUTI, the risk of acquiring secondary bacteremia was lower (100% for the patients using noble metal alloy catheters (3 cases in the standard group vs. 0 case in the noble metal alloy catheter group, P = 0.24. No adverse events related to any of the used catheters were recorded. Conclusion: Results from this study revealed that noble metal alloy catheters are safe to use and significantly reduce CAUTI rate in ICU patients after 3 days of use.

  20. Attitudes Towards Catheter Ablation for Atrial Fibrillation

    DEFF Research Database (Denmark)

    Vadmann, Henrik; Pedersen, Susanne S; Nielsen, Jens Cosedis;

    2015-01-01

    BACKGROUND: Catheter ablation for atrial fibrillation (AF) is an important but expensive procedure that is the subject of some debate. Physicians´ attitudes towards catheter ablation may influence promotion and patient acceptance. This is the first study to examine the attitudes of Danish...

  1. Soft thrombus formation in radiofrequency catheter ablation

    NARCIS (Netherlands)

    Demolin, JM; Eick, OJ; Munch, K; Koullick, E; Nakagawa, H; Wittkampf, FHM

    2002-01-01

    During RF catheter ablation, local temperature elevation can result in coagulum formation on the ablation electrode, resulting in impedance rise. A recent study has also demonstrated the formation of a so-called soft thrombus during experimental ablations. This deposit poorly adhered to the catheter

  2. Catheter ablation of parahisian premature ventricular complex.

    Science.gov (United States)

    Kim, Jun; Kim, Jeong Su; Park, Yong Hyun; Kim, June Hong; Chun, Kook Jin

    2011-12-01

    Catheter ablation is performed in selected patients with a symptomatic premature ventricular complex (PVC) or PVC-induced cardiomyopathy. Ablation of PVC from the His region has a high risk of inducing a complete atrioventricular block. Here we report successful catheter ablation of a parahisian PVC in a 63-year-old man.

  3. Urethral catheters: can we reduce use?

    NARCIS (Netherlands)

    Broek, P.J. van den; Wille, J.C.; Benthem, B.H.B. van; Perenboom, R.J.M.; Akker-van Marle, M.E. van den; Nielen, A.M.A.

    2011-01-01

    Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. The efficacy of an intervention programme to improve adherence to recommenda

  4. Automated Pointing of Cardiac Imaging Catheters.

    Science.gov (United States)

    Loschak, Paul M; Brattain, Laura J; Howe, Robert D

    2013-12-31

    Intracardiac echocardiography (ICE) catheters enable high-quality ultrasound imaging within the heart, but their use in guiding procedures is limited due to the difficulty of manually pointing them at structures of interest. This paper presents the design and testing of a catheter steering model for robotic control of commercial ICE catheters. The four actuated degrees of freedom (4-DOF) are two catheter handle knobs to produce bi-directional bending in combination with rotation and translation of the handle. An extra degree of freedom in the system allows the imaging plane (dependent on orientation) to be directed at an object of interest. A closed form solution for forward and inverse kinematics enables control of the catheter tip position and the imaging plane orientation. The proposed algorithms were validated with a robotic test bed using electromagnetic sensor tracking of the catheter tip. The ability to automatically acquire imaging targets in the heart may improve the efficiency and effectiveness of intracardiac catheter interventions by allowing visualization of soft tissue structures that are not visible using standard fluoroscopic guidance. Although the system has been developed and tested for manipulating ICE catheters, the methods described here are applicable to any long thin tendon-driven tool (with single or bi-directional bending) requiring accurate tip position and orientation control.

  5. [Pliability and deflection of diagnostic catheters].

    Science.gov (United States)

    Pelyhe, Liza; Bognár, Eszter

    2014-09-28

    The cardiac catheter is an intravascular catheter, which is introduced or implanted into the heart for diagnostic or therapeutic reasons. The catheters may break or king during their introduction and/or removal. The aim of the authors was to study the pliability of two catheters with the same material but different diameters according to the Food and Drug Administration's recommendation. The bending points, diameter decrease, deflection, and their correlation and dependence on the distance from the tip, as well as the influence of the initial diameter of the catheters were determined. The bending of catheters was performed on 9 bending points (120-280 mm from the tip by 20 mm) on 16 gauges with different radius (10-2.5 mm by 0.5 mm). A linear dependency between the diameter decrease and deflection was observed, which was independent from the placement of the measurement in both catheters examined. The larger initial diameter had significant (p = 0.05) greater diameter decrease than the smaller, but the curves characteristic of the diameter decrease and deflection were similar. The applied method seems to be useful for the examination of weak points of cardiac catheters.

  6. Cumulative early life adversity predicts longevity in wild baboons.

    Science.gov (United States)

    Tung, Jenny; Archie, Elizabeth A; Altmann, Jeanne; Alberts, Susan C

    2016-04-19

    In humans and other animals, harsh circumstances in early life predict morbidity and mortality in adulthood. Multiple adverse conditions are thought to be especially toxic, but this hypothesis has rarely been tested in a prospective, longitudinal framework, especially in long-lived mammals. Here we use prospective data on 196 wild female baboons to show that cumulative early adversity predicts natural adult lifespan. Females who experience ≥3 sources of early adversity die a median of 10 years earlier than females who experience ≤1 adverse circumstances (median lifespan is 18.5 years). Females who experience the most adversity are also socially isolated in adulthood, suggesting that social processes partially explain the link between early adversity and adult survival. Our results provide powerful evidence for the developmental origins of health and disease and indicate that close ties between early adversity and survival arise even in the absence of health habit and health care-related explanations.

  7. Central Venous Catheter-Related Hydrothorax

    Directory of Open Access Journals (Sweden)

    Se Hun Kim

    2015-11-01

    Full Text Available This report describes a case of 88-year-old women who developed central venous catheter-related bilateral hydrothorax, in which left pleural effusion, while right pleural effusion was being drained. The drainage prevented accumulation of fluid in the right pleural space, indicating that there was neither extravasation of infusion fluid nor connection between the two pleural cavities. The only explanation for bilateral hydrothorax in this case is lymphatic connections. Although vascular injuries by central venous catheter can cause catheter-related hydrothorax, it is most likely that the positioning of the tip of central venous catheter within the lymphatic duct opening in the right sub-clavian-jugular confluence or superior vena cava causes the catheter-related hydrothorax. Pericardial effusion can also result from retrograde lymphatic flow through the pulmonary lymphatic chains.

  8. Unusual migration of pulmonary artery catheter

    Directory of Open Access Journals (Sweden)

    Sanjay Kuravinakop

    2007-01-01

    Full Text Available Pulmonary artery catheter is widely used in intensive care. Distal migration of the catheter is a know complication. Diagnosis of such a migration is made by both clinical criteria and radiographs. A 55 year old septic lady was admitted to the intensive care unit. Pulmonary artery catheter introduced for cardiac output monitoring migrated from right lung to left lung. Diagnosis was made following a chest radiograph the following day of insertion with the clinical criteria remaining unaltered. Migration of pulmonary artery catheter can occur not only distally but from one lung to another. Clinical criteria alone cannot rule out migration. Chest radiographs form an important part in monitoring the position of the pulmonary artery catheter.

  9. Complex central venous catheter insertion for hemodialysis.

    Science.gov (United States)

    Powell, Steven; Belfield, Jane

    2014-01-01

    Despite the introduction of payment by results in the UK, there has been no decrease in central venous catheter (CVC) use. In part, this may relate to a requirement to dialyse through a CVC while autogenous access matures. Mortality data have improved in parallel and patients on hemodialysis live longer, which may lead to an increased exposure to CVCs.Exposure to CVCs carries a significant risk of infection and occlusion requiring their repositioning or exchange. The mid to long-term sequelae of CVC use is central venous occlusion leaving clinical teams with an ever increasing challenge to find adequate venous access.In this article, we will discuss the challenges faced by operators inserting CVCs into the hemodialysis-dependent patient who has exhausted more tradition insertion sites. These include translumbar caval catheters, transocclusion and transcollateral catheters, transjugular Inferior Vena Cava catheter positioning, and transhepatic catheters. We will demonstrate the techniques employed, complications, and anticipated longevity of function.

  10. Central venous catheters: detection of catheter complications and therapeutical options; Zentralvenoese Katheter: Diagnostik von Komplikationen und therapeutische Optionen

    Energy Technology Data Exchange (ETDEWEB)

    Gebauer, B.; Beck, A. [Universitaetsmedizin Charite, Berlin (Germany). Klinik fuer Strahlenheilkunde; Wagner, H.J. [Vivantes-Kliniken, Friedrichshain und Am Urban, Berlin (Germany). Radiologie; Vivantes-Kliniken, Hellersdorf und Prenzlauer Berg (Germany). Radiologie

    2008-06-15

    For modern medicine central venous catheters play an important role for diagnostic and therapeutic options. Catheter implantation, complication detection and therapy of catheter complications are an increasing demand for the radiologist. The review article provides an overview of different catheter types, their indications, advantages and disadvantages. Catheter malpositions are usually detectable in conventional X-ray. Most malpositions are correctable using interventional-radiological techniques. In addition therapeutical options for thrombotic complications (venous thrombosis, catheter occlusion, fibrin sheath) are discussed. In case of an infectious catheter complication, usually a catheter extraction and re-implantation is necessary.

  11. Cumulative cultural learning: Development and diversity.

    Science.gov (United States)

    Legare, Cristine H

    2017-07-24

    The complexity and variability of human culture is unmatched by any other species. Humans live in culturally constructed niches filled with artifacts, skills, beliefs, and practices that have been inherited, accumulated, and modified over generations. A causal account of the complexity of human culture must explain its distinguishing characteristics: It is cumulative and highly variable within and across populations. I propose that the psychological adaptations supporting cumulative cultural transmission are universal but are sufficiently flexible to support the acquisition of highly variable behavioral repertoires. This paper describes variation in the transmission practices (teaching) and acquisition strategies (imitation) that support cumulative cultural learning in childhood. Examining flexibility and variation in caregiver socialization and children's learning extends our understanding of evolution in living systems by providing insight into the psychological foundations of cumulative cultural transmission-the cornerstone of human cultural diversity.

  12. Evaluation of an intravenous catheter for use in the horse.

    Science.gov (United States)

    Gulick, B A; Meagher, D M

    1981-02-01

    A commercially available polyvinyl chloride intravenous catheter was studied in 9 horses for 3 to 10 days to evaluate the catheter's suitability for use in the horse, to develop a new insertion technique, and to establish a protocol for catheter care. Seven of the animals were clinically normal horses receiving parenteral nutrition; one was a horse with hypocalcemia receiving frequent intravenous injections of calcium gluconate, and one was a clinically normal horse receiving no infusions. The catheter dressings were changed every 48 hours, and an aspirate from the catheter and the catheter tip was cultured at the time of catheter removal. One catheter became infected following a break in the protocol. It was concluded that the polyvinyl catheter is suitable for use in the horse and that the proposed protocol for catheter insertion and maintenance may reduce the likelihood of complications such as catheter sepsis, thrombophlebitis, and embolism.

  13. Calculating Cumulative Binomial-Distribution Probabilities

    Science.gov (United States)

    Scheuer, Ernest M.; Bowerman, Paul N.

    1989-01-01

    Cumulative-binomial computer program, CUMBIN, one of set of three programs, calculates cumulative binomial probability distributions for arbitrary inputs. CUMBIN, NEWTONP (NPO-17556), and CROSSER (NPO-17557), used independently of one another. Reliabilities and availabilities of k-out-of-n systems analyzed. Used by statisticians and users of statistical procedures, test planners, designers, and numerical analysts. Used for calculations of reliability and availability. Program written in C.

  14. Catheter visualisation in MR tomography: first animal experimental experiences with field inhomogeneity catheters; Kathetervisualisierung in der MR-Tomographie: erste tierexperimentelle Erfahrungen mit Feldinhomogenitaetskathetern

    Energy Technology Data Exchange (ETDEWEB)

    Adam, G. [Technische Hochschule Aachen (Germany). Klinik fue Radiologische Diagnostik; Glowinski, A. [Technische Hochschule Aachen (Germany). Klinik fue Radiologische Diagnostik; Neuerburg, J.; Buecker, A.; Vaals, J.J. van; Hurtak, W.; Guenther, R.W.

    1997-04-01

    Purpose: To assess the feasibility of a new developed field inhomogeneity catheter for interventional MR imaging in vivo. Materials and methods: Three different prototypes of a field inhomogeneity catheter were investigated in 6 pigs. The catheters were introduced in Seldinger technique via the femoral vessels over a guide wire on an interventional MR system (Philips Gyroscan NT combined with a C-arm fluoroscopy unit [Philips BV 212]). Catheters were placed in veins and arteries. The catheter position was controlled by a fast gradient echo sequence (Turbo Field Echo [TEF]). Results: Catheters were introduced over a guide wire without complications in all cases. Using the field inhomogeneity concept, catheters were easily visualised in the inferior vena cava and the aorta by the fast gradient echo technique on MR in all cases. Although aortic branches were successfully cannulated, the catheters were not displayed by the TFE technique due to the complex and tortuous anatomy. All animals survived the experiments without complications. Conclusion: MR guided visualisation of a field inhomogeneity catheter is a simple concept which can be realised on each MR scanner and may allow intravascular MR guided interventions in future. (orig.) [Deutsch] Zielsetzung: Ziel der Untersuchungen war die Ueberpruefung der Tauglichkeit eines neu entwickelten Feldinhomogenitaetskatheters fuer die interventionelle MR-Tomographie in vivo. Material und Methoden: An 6 Schweinen wurden an einem interventionellen MR-Tomographen (Philips Gyroscan NT in Verbindung mit einer C-Bogen-Durchleuchtungseinheit [Philips BV 212]) in Seldinger-Technik ueber die Femoralgefaesse drei verschiedene Prototypen eines neu entwickelten Feldinhomogenitaetskatheters venoes und arteriell plaziert und mittels schneller Gradienten-Echo-Sequenzen (Turbo Field Echo) MR-tomographisch dargestellt. Ergebnisse: Alle Katheter konnten problemlos ueber Fuehrungsdraehte in das Gefaesssystem eingefuehrt werden. Die Darstellung

  15. Cumulative cultural evolution: the role of teaching.

    Science.gov (United States)

    Castro, Laureano; Toro, Miguel A

    2014-04-21

    In humans, cultural transmission occurs usually by cumulative inheritance, generating complex adaptive behavioral features. Cumulative culture requires key psychological processes (fundamentally imitation and teaching) that are absent or impoverished in non-human primates. In this paper we analyze the role that teaching has played in human cumulative cultural evolution. We assume that a system of cumulative culture generates increasingly adaptive behaviors, that are also more complex and difficult to imitate. Our thesis is that, as cultural traits become more complex, cumulative cultural transmission requires teaching to ensure accurate transmission from one generation to the next. In an increasingly complex cultural environment, we consider that individuals commit errors in imitation. We develop a model of cumulative cultural evolution in a changing environment and show that these errors hamper the process of cultural accumulation. We also show that a system of teaching between parents and offspring that increases the fidelity of imitation unblocks the accumulation and becomes adaptive whenever the gain in fitness compensates the cost of teaching.

  16. Human cumulative culture: a comparative perspective.

    Science.gov (United States)

    Dean, Lewis G; Vale, Gill L; Laland, Kevin N; Flynn, Emma; Kendal, Rachel L

    2014-05-01

    Many animals exhibit social learning and behavioural traditions, but human culture exhibits unparalleled complexity and diversity, and is unambiguously cumulative in character. These similarities and differences have spawned a debate over whether animal traditions and human culture are reliant on homologous or analogous psychological processes. Human cumulative culture combines high-fidelity transmission of cultural knowledge with beneficial modifications to generate a 'ratcheting' in technological complexity, leading to the development of traits far more complex than one individual could invent alone. Claims have been made for cumulative culture in several species of animals, including chimpanzees, orangutans and New Caledonian crows, but these remain contentious. Whilst initial work on the topic of cumulative culture was largely theoretical, employing mathematical methods developed by population biologists, in recent years researchers from a wide range of disciplines, including psychology, biology, economics, biological anthropology, linguistics and archaeology, have turned their attention to the experimental investigation of cumulative culture. We review this literature, highlighting advances made in understanding the underlying processes of cumulative culture and emphasising areas of agreement and disagreement amongst investigators in separate fields.

  17. Radiologic placement of tunneled central venous catheter

    Energy Technology Data Exchange (ETDEWEB)

    Hahn, Seong Tae; Yang, Po Song; Yang, Dong Hunn; Kim, Ki Tae; Kim, Choon Yul; Shinn, Kyung Sub [The Catholic Univ. College of Medicine, Seoul (Korea, Republic of); Yun, Eun Joo [Korea Veterans Hospital, Seoul (Korea, Republic of)

    1996-01-01

    To evaluate the efficacy and safety of fluoroscopy-guided, radiologic placement of a tunneled central venous catheter into the superior vena cava (SVC). Thirty five patients underwent tunneled central venous catheter placement to facilitate long-term chemotherapy. They included 33 leukemic patients, one colon cancer patient, and one multiple myeloma patient. After confirming central venous patency with a injection of contrast media via the peripheral cephalic or basilic vein in the wrist joint, the subclavian vein was punctured under fluoroscopic guidance. A 7F double lumen TPN catheter was placed into the SVC through a subcutaneous tunnel in the anterior chest wall. Catheter placements were successful in all patients. The mean procedure time was 17.2minutes, mean fluooscopy time was 1.3minutes, mean number of punctures was 1.4, and mean volume of injhected contrast media was 43.5cc. Only two of all leukemic patients developed mild hematomas at the puncture site, but these soon resolved themselves. None of the patients developed pneumothorax or hemothorax. But late complications included local infection in two patients (6%) and thrombotic occlusion of the catheter in one (3%). The occluded catheter was successfully recanalized with Urokinase infusion. Fluoroscopy-guided, radiologic placement of a tunneled central venous catheter is an easy and safe method, and useful for patients requiring long-term venous access.

  18. [Updating enteral feeding by catheter].

    Science.gov (United States)

    Rodríguez, T; Planas, M

    2005-12-01

    Intestinal nutrition can be administered orally or by means of a catheter; the latter method is the focus of this article. The authors' objective is to provide up-to-date information in a succinct manner about the enteral feeding technique. The authors hope health professionals know the advantages as well as the inconveniences of the latest intestinal nutrition advances regarding access ways and the means to administer these. Intestinal nutrition formulas will not be dealt with in this article. However, a health professional should know that there is a wide variety of diets available depending on the complexity of macronutrients included in a diet, the quantity of proteins in a mixture, and that these are designed, in addition to feeding, to treat the specific pathological process a patient suffers from, such as diabetes of cancer.

  19. Cryoballoon Catheter Ablation in Atrial Fibrillation

    Directory of Open Access Journals (Sweden)

    Cevher Ozcan

    2011-01-01

    Full Text Available Pulmonary vein isolation with catheter ablation is an effective treatment in patients with symptomatic atrial fibrillation refractory or intolerant to antiarrhythmic medications. The cryoballoon catheter was recently approved for this procedure. In this paper, the basics of cryothermal energy ablation are reviewed including its ability of creating homogenous lesion formation, minimal destruction to surrounding vasculature, preserved tissue integrity, and lower risk of thrombus formation. Also summarized here are the publications describing the clinical experience with the cryoballoon catheter ablation in both paroxysmal and persistent atrial fibrillation, its safety and efficacy, and discussions on the technical aspect of the cryoballoon ablation procedure.

  20. Percutaneous catheter dilatation of carotid stenoses

    Energy Technology Data Exchange (ETDEWEB)

    Mathias, K.; Mittermayer, C.; Ensinger, H.; Neff, W.

    1980-09-01

    Thirty-one carotid artery stenoses were produced in thirty dogs by three different techniques. Twenty-three of these could be cured by transfemoral percutaneous catheter dilatation. High grade tight stenoses may present resistance which cannot be overcome by the catheter. Histological examination of the dilated vessels showed circumscribed changes in the vessel wall, with destruction of elastic membranes. From our experience of catheter dilatation of pelvic and lower limb arteries and of renal arteries, we consider it feasible to use this technique in selected patients with carotid stenosis.

  1. Preventing catheter-associated urinary tract infection.

    Science.gov (United States)

    Gould, Dinah

    2015-11-04

    Urinary tract infections (UTIs) are common in hospital and community settings. The major risk factor for developing a UTI is having a urethral catheter in situ. The longer the catheter remains in place, the higher the risk of infection. The consensus in guidelines is that indwelling urethral catheters should not be used unless necessary and should be removed within 24 hours if possible. The care of patients and nursing home residents who are catheterised for long periods could be improved if guidelines were implemented fully.

  2. Catheter-directed Thrombolysis in Acute Superior Vena Cava Syndrome Caused by Central Venous Catheters.

    Science.gov (United States)

    Cui, Jie; Kawai, Tasuo; Irani, Zubin

    2015-01-01

    Indwelling central venous catheters have been reported to increase the risk of superior venous cava (SVC) syndrome. This case report describes the development of acute SVC syndrome in a 28-year-old woman with end-stage renal disease implanted with a left-side hemodialysis reliable outflow graft and a right-side double lumen hemodialysis catheter via internal jugular veins. Her symptoms were not alleviated after catheter removal and systemic anticoagulation therapy. She was eventually treated with catheter-directed thrombolysis and a predischarge computer tomographic venogram on postthrombolytic procedure day 7 showed patent central veins and patient remained asymptomatic. This case demonstrates that catheter-directed thrombolysis can be safely employed to treat refractory catheter-induced acute SVC syndrome in end-stage renal disease patients.

  3. Retained Urethral Catheter Secondary to Placement in Proximal Ureter

    Directory of Open Access Journals (Sweden)

    Thomas B. McGregor

    2016-01-01

    Full Text Available We present an unusual complication secondary to indwelling urethral catheter placement. Routine catheter placement by the obstetrics team in a postpartum female leads to retention of the catheter and inability of its removal by both the obstetrics and urology teams. Although a retained urinary catheter is relatively common, inability to remove a catheter secondary to placement inadvertently into a ureter is extremely rare. In this paper we will discuss the options in removing a retained catheter and present our case of a retained catheter secondary to placement within the right proximal ureter.

  4. Retained Urethral Catheter Secondary to Placement in Proximal Ureter.

    Science.gov (United States)

    McGregor, Thomas B; Sharda, Rajan

    2016-01-01

    We present an unusual complication secondary to indwelling urethral catheter placement. Routine catheter placement by the obstetrics team in a postpartum female leads to retention of the catheter and inability of its removal by both the obstetrics and urology teams. Although a retained urinary catheter is relatively common, inability to remove a catheter secondary to placement inadvertently into a ureter is extremely rare. In this paper we will discuss the options in removing a retained catheter and present our case of a retained catheter secondary to placement within the right proximal ureter.

  5. Predicting Cumulative Incidence Probability by Direct Binomial Regression

    DEFF Research Database (Denmark)

    Scheike, Thomas H.; Zhang, Mei-Jie

    Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard......Binomial modelling; cumulative incidence probability; cause-specific hazards; subdistribution hazard...

  6. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    1991-01-01

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  7. THE KISSING BALLOON TECHNIQUE WITH 2 OVER-THE-WIRE BALLOON CATHETERS THROUGH A SINGLE 8-FRENCH GUIDING CATHETER

    NARCIS (Netherlands)

    DENHEIJER, P; BERNINK, PJLM; VANDIJK, RB; TWISK, SPM; LIE, KI

    Some of the newer over-the-wire coronary angioplasty catheters have shaft sizes of 3.0 French (F) or less. The inner diameter of modern 8-F guiding catheters is large enough to accommodate two of such balloon catheters. We report a kissing balloon procedure with two over-the-wire catheters through a

  8. A Survey of Invasive Catheter Practices in US Burn Centers

    Science.gov (United States)

    2012-12-01

    central venous cannulation in children: lessons learned from a 10-year experience placing more than 1000 catheters . J Burn Care Res 2006;27:713–18. ...741 Central venous catheters (CVCs) and arterial catheters (ACs) provide essential access for critically injured patients. Practices surrounding...consisted of 23 questions related to spe- cific practices in placement and maintenance of central venous catheters (CVCs), arte- rial catheters ,

  9. Plasticity and rectangularity in survival curves

    Science.gov (United States)

    Weon, Byung Mook; Je, Jung Ho

    2011-09-01

    Living systems inevitably undergo a progressive deterioration of physiological function with age and an increase of vulnerability to disease and death. To maintain health and survival, living systems should optimize survival strategies with adaptive interactions among molecules, cells, organs, individuals, and environments, which arises plasticity in survival curves of living systems. In general, survival dynamics in a population is mathematically depicted by a survival rate, which monotonically changes from 1 to 0 with age. It would be then useful to find an adequate function to describe complicated survival dynamics. Here we describe a flexible survival function, derived from the stretched exponential function by adopting an age-dependent shaping exponent. We note that the exponent is associated with the fractal-like scaling in cumulative mortality rate. The survival function well depicts general features in survival curves; healthy populations exhibit plasticity and evolve towards rectangular-like survival curves, as examples in humans or laboratory animals.

  10. Catheter-Associated Urinary Tract Infections

    Science.gov (United States)

    ... Submit Button Frequently Asked Questions about Catheter-associated Urinary Tract Infections Recommend on Facebook Tweet Share Compartir What is ... an incision above the pubis. What is a urinary tract infection? A urinary tract infection (UTI) is an infection ...

  11. Cumulative radiation exposure and cancer risk of patients with ischemic heart diseases from diagnostic and therapeutic imaging procedures

    Energy Technology Data Exchange (ETDEWEB)

    Brix, Gunnar, E-mail: gbrix@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingoldstädter Landstraße 1, D-85764 Oberschleissheim (Germany); Berton, Marc, E-mail: marcberton@web.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Nekolla, Elke, E-mail: enekolla@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingoldstädter Landstraße 1, D-85764 Oberschleissheim (Germany); Lechel, Ursula, E-mail: ulechel@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingoldstädter Landstraße 1, D-85764 Oberschleissheim (Germany); Schegerer, Alexander, E-mail: aschegerer@bfs.de [Department of Medical and Occupational Radiation Protection, Federal Office for Radiation Protection, Ingoldstädter Landstraße 1, D-85764 Oberschleissheim (Germany); Süselbeck, Tim, E-mail: Tim.Sueselbeck@umm.de [Department of Cardiology, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany); Fink, Christian, E-mail: Christian.Fink@umm.de [Institute of Clinical Radiology and Nuclear Medicine, University Medical Center Mannheim, University of Heidelberg, Theodor-Kutzer-Ufer 1-3, D-68167 Mannheim (Germany)

    2013-11-01

    Objectives: To present a detailed analysis of the cumulative radiation exposure and cancer risk of patients with ischemic heart diseases (IHD) from diagnostic and therapeutic imaging. Methods: For 1219 IHD patients, personal and examination data were retrieved from the information systems of a university hospital. For each patient, cumulative organ doses and the corresponding effective dose (E{sup ¯}) resulting from all imaging procedures performed within 3 months before and 12 months after the date of the diagnosis were calculated. The cumulative lifetime attributable risk (LAR{sup ¯}) of the patients to be diseased by radiation-related cancer was estimated using sex-, age-, and organ-specific risk models. Results: Among the 3870 procedures performed in the IHD patients, the most frequent were radiographic examinations (52.4%) followed by coronary catheter angiographies and percutaneous cardiac interventions (41.3%), CT scans (3.9%), and perfusion SPECT (2.3%). 87% of patient exposure resulted from heart catheter procedures. E{sup ¯} and LAR{sup ¯} were significantly higher in males than females (average, 13.3 vs. 10.3 mSv and 0.09 vs. 0.07%, respectively). Contrary to the effective dose, the cancer risk decreased markedly for both sexes with increasing age. Conclusions: Although IHD patients were partially exposed to considerable amounts of radiation, estimated LAR{sup ¯}s were small as compared to their baseline risk to develop cancer in the remaining life.

  12. Advanced Imaging Catheter: Final Project Report

    Energy Technology Data Exchange (ETDEWEB)

    Krulevitch, P; Colston, B; DaSilva, L; Hilken, D; Kluiwstra, J U; Lee, A P; London, R; Miles, R; Schumann, D; Seward, K; Wang, A

    2001-07-20

    Minimally invasive surgery (MIS) is an approach whereby procedures conventionally performed with large and potentially traumatic incisions are replaced by several tiny incisions through which specialized instruments are inserted. Early MIS, often called laparoscopic surgery, used video cameras and laparoscopes to visualize and control the medical devices, which were typically cutting or stapling tools. More recently, catheter-based procedures have become a fast growing sector of all surgeries. In these procedures, small incisions are made into one of the main arteries (e.g. femoral artery in the thigh), and a long thin hollow tube is inserted and positioned near the target area. The key advantage of this technique is that recovery time can be reduced from months to a matter of days. In the United States, over 700,000 catheter procedures are performed annually representing a market of over $350 million. Further growth in this area will require significant improvements in the current catheter technology. In order to effectively navigate a catheter through the tortuous vessels of the body, two capabilities must exist: imaging and positioning. In most cases, catheter procedures rely on radiography for visualization and manual manipulation for positioning of the device. Radiography provides two-dimensional, global images of the vasculature and cannot be used continuously due to radiation exposure to both the patient and physician. Intravascular ultrasound devices are available for continuous local imaging at the catheter tip, but these devices cannot be used simultaneously with therapeutic devices. Catheters are highly compliant devices, and manipulating the catheter is similar to pushing on a string. Often, a guide wire is used to help position the catheter, but this procedure has its own set of problems. Three characteristics are used to describe catheter maneuverability: (1) pushability -- the amount of linear displacement of the distal end (inside body) relative to

  13. Cumulative Culture and Future Thinking: Is Mental Time Travel a Prerequisite to Cumulative Cultural Evolution?

    Science.gov (United States)

    Vale, G. L.; Flynn, E. G.; Kendal, R. L.

    2012-01-01

    Cumulative culture denotes the, arguably, human capacity to build on the cultural behaviors of one's predecessors, allowing increases in cultural complexity to occur such that many of our cultural artifacts, products and technologies have progressed beyond what a single individual could invent alone. This process of cumulative cultural evolution…

  14. Is cumulated pyrethroid exposure associated with prediabetes?

    DEFF Research Database (Denmark)

    Hansen, Martin Rune; Jørs, Erik; Lander, Flemming;

    2014-01-01

    , cumulative exposure) was assessed from questionnaire data. Participants were asked about symptoms of diabetes. Blood samples were analyzed for glycosylated hemoglobin (HbA1c), a measure of glucose regulation. No association was found between pyrethroid exposure and diabetes symptoms. The prevalence...

  15. Cumulative Disadvantage among the Highly Ambitious.

    Science.gov (United States)

    McClelland, Katherine

    1990-01-01

    Using a social reproduction theory framework, analyzes the process by which high school seniors aspiring to high-level positions are sorted out after graduation. Analyzes early educational attainments and changes in occupational expectations. Shows a process of cumulative disadvantage in which White males are more likely to achieve their goals.…

  16. Pavlovian conditioning and cumulative reinforcement rate.

    Science.gov (United States)

    Harris, Justin A; Patterson, Angela E; Gharaei, Saba

    2015-04-01

    In 5 experiments using delay conditioning of magazine approach with rats, reinforcement rate was varied either by manipulating the mean interval between onset of the conditioned stimulus (CS) and unconditioned stimulus (US) or by manipulating the proportion of CS presentations that ended with the US (trial-based reinforcement rate). Both manipulations influenced the acquisition of responding. In each experiment, a specific comparison was made between 2 CSs that differed in their mean CS-US interval and in their trial-based reinforcement rate, such that the cumulative reinforcement rate-the cumulative duration of the CS between reinforcements-was the same for the 2 CSs. For example, a CS reinforced on 100% of trials with a mean CS-US interval of 60 s was compared with a CS reinforced on 33% of trials and a mean duration of 20 s. Across the 5 experiments, conditioning was virtually identical for the 2 CSs with matched cumulative reinforcement rate. This was true as long as the timing of the US was unpredictable and, thus, response rates were uniform across the length of the CS. We conclude that the effects of CS-US interval and of trial-based reinforcement rate are reducible entirely to their common effect on cumulative reinforcement rate. We discuss the implications of this for rate-based, trial-based, and real-time associative models of conditioning.

  17. An Axiomatization of Cumulative Prospect Theory

    NARCIS (Netherlands)

    Wakker, P.P.; Tversky, A.

    1993-01-01

    This paper presents a method for axiomatizing a variety of models for decision making under uncertainty, including Expected Utility and Cumulative Prospect Theory. This method identifies, for each model, the situations that permit consistent inferences about the ordering of value differences. Exampl

  18. Cumulative Disadvantage among the Highly Ambitious.

    Science.gov (United States)

    McClelland, Katherine

    1990-01-01

    Using a social reproduction theory framework, analyzes the process by which high school seniors aspiring to high-level positions are sorted out after graduation. Analyzes early educational attainments and changes in occupational expectations. Shows a process of cumulative disadvantage in which White males are more likely to achieve their goals.…

  19. Cumulative Incidence Association Models for Bivariate Competing Risks Data.

    Science.gov (United States)

    Cheng, Yu; Fine, Jason P

    2012-03-01

    Association models, like frailty and copula models, are frequently used to analyze clustered survival data and evaluate within-cluster associations. The assumption of noninformative censoring is commonly applied to these models, though it may not be true in many situations. In this paper, we consider bivariate competing risk data and focus on association models specified for the bivariate cumulative incidence function (CIF), a nonparametrically identifiable quantity. Copula models are proposed which relate the bivariate CIF to its corresponding univariate CIFs, similarly to independently right censored data, and accommodate frailty models for the bivariate CIF. Two estimating equations are developed to estimate the association parameter, permitting the univariate CIFs to be estimated either parametrically or nonparametrically. Goodness-of-fit tests are presented for formally evaluating the parametric models. Both estimators perform well with moderate sample sizes in simulation studies. The practical use of the methodology is illustrated in an analysis of dementia associations.

  20. Early start of combination therapy with hemodialysis and peritoneal dialysis prolongs survival and reduces cardiovascular events in male patients.

    Science.gov (United States)

    Suzuki, Hiromichi; Hoshi, Hitosi; Inoue, Tsutomu; Kikuta, Tomohiro; Tsuda, Masahiro; Takenaka, Tsuneo

    2012-01-01

    Although peritoneal dialysis (PD) has been recommended for initial dialysis therapy, a larger proportion of patients with end-stage renal disease choose hemodialysis (HD) instead. Several previous studies comparing the outcomes of these two therapies, including survival rates and cardiovascular events, have not clearly demonstrated the superiority of one over the other. Our recent study indicated that, compared with HD or PD alone, renal replacement therapy with HD and PD in combination prolongs survival and reduces cardiovascular events. However, the use of combination dialysis therapy is not widely accepted. We set out to analyze the efficacy of combination dialysis therapy with PD and HD in patients who started with PD as initial dialysis therapy. Our single-center retrospective cohort study included 401 patients (165 women, 236 men; 61 +/- 12 and 62 +/- 9 years of age respectively) who started PD during 1995-2005. Chart and electronic databases were used to obtain information on the course of dialysis therapy, including mortality and cardiovascular events. Treatment with HD and PD in combination was used in 103 patients. During 5 years of follow-up after the start of PD, 80 patients died. We observed no differences in cumulative mortality between the men (49, 200%) and women (31, 18%) and no difference in the cumulative incidence of catheter removal for various reasons (35% vs. 31%). There was a significant difference (p dialysis patient population, women on PD experience mortality similar to that in men. The reasons for those findings have not been fully explained. The present analysis suggests that an early start to HD therapy will prolong the survival of patients on PD, especially men.

  1. Choice of valve type and poor ventricular catheter placement: Modifiable factors associated with ventriculoperitoneal shunt failure.

    Science.gov (United States)

    Jeremiah, Kealeboga Josephine; Cherry, Catherine Louise; Wan, Kai Rui; Toy, Jennifer Ah; Wolfe, Rory; Danks, Robert Andrew

    2016-05-01

    Ventriculoperitoneal (VP) shunt insertion is a common neurosurgical procedure, essentially unchanged in recent years, with high revision rates. We aimed to identify potentially modifiable associations with shunt failure. One hundred and forty patients who underwent insertion of a VP shunt from 2005-2009 were followed for 5-9years. Age at shunt insertion ranged from 0 to 91years (median 44, 26% hydrocephalus were congenital (26%), tumour-related (25%), post-haemorrhagic (24%) or normal pressure hydrocephalus (19%). Fifty-eight (42%) patients required ⩾1 shunt revision. Of these, 50 (88%) were for proximal catheter blockage. The median time to first revision was 108days. Early post-operative CT scans were available in 105 patients. Using a formal grading system, catheter placement was considered excellent in 49 (47%) but poor (extraventricular) in 13 (12%). On univariate analysis, younger age, poor ventricular catheter placement and use of a non-programmable valve were associated with shunt failure. On logistic regression modelling, the independent associations with VP shunt failure were poor catheter placement (odds ratio [OR] 4.9, 95% confidence interval [CI] 1.3-18.9, p=0.02) and use of a non-programmable valve (OR 0.4, 95% CI 0.2-1.0, p=0.04). In conclusion, poor catheter placement (revision rate 77%) was found to be the strongest predictor of shunt failure, with no difference in revisions between excellent (43%) and moderate (43%) catheter placement. Avoiding poor placement in those with mild or moderate ventriculomegaly may best reduce VP shunt failures. There may also be an influence of valve choice on VP shunt survival.

  2. Toxic catheters and urethral strictures: A concern about types of catheters used in resource-poor countries

    Directory of Open Access Journals (Sweden)

    A.A. Popoola

    2012-12-01

    Full Text Available Various reports in the literature have confirmed urethral toxicity caused by the use of catheters, mostly latex catheters and their coated versions, resulting in long-segment urethral strictures or strictures located in multiple areas of the urethra. Most catheters used in resource-poor countries, such as Nigeria, are latex catheters with various coatings, such as silicone. The reasons for the widespread use of these potentially toxic catheters are mainly non-availability and/or the high cost of less toxic catheters. We report three cases of urethral strictures following the use of siliconized latex catheters in order to highlight the potential urethral toxicity associated with the use of latex catheters and to draw the authorities’ attention to the need to regulate the types of catheters used in the country.

  3. Malfunctioning central venous catheters in children: a diagnostic approach

    Energy Technology Data Exchange (ETDEWEB)

    Barnacle, Alex; Arthurs, Owen J.; Roebuck, Derek; Hiorns, Melanie P. [Great Ormond Street Hospital, Radiology Department, London (United Kingdom)

    2008-04-15

    Central venous access is increasingly becoming the domain of the radiologist, both in terms of the insertion of central venous catheters (CVCs) and in the subsequent management of these lines. This article seeks to provide an overview of the CVC types available for paediatric patients and a more detailed explanation of the spectrum of complications that may lead to catheter malfunction. A standard catheter contrast study or 'linogram' technique is described. The normal appearances of such a study and a detailed pictorial review of abnormal catheter studies are provided, together with a brief overview of how information from catheter investigations can guide the management of catheter complications. (orig.)

  4. Percutaneous catheter drainage of intrapulmonary fluid collection

    Energy Technology Data Exchange (ETDEWEB)

    Park, E. D.; Kim, H. J.; Choi, P. Y.; Jung, S. H. [Gyeongsang National University Hospital, Chinju (Korea, Republic of)

    1994-01-15

    With the success of percutaneous abdominal abscess drainage, attention is now being focused on the use of similar techniques in the thorax. We studied to evaluate the effect of percutaneous drainage in parenchymal fluid collections in the lungs. We performed percutaneous drainage of abscesses and other parenchymal fluid collections of the lungs in 15 patients. All of the procedures were performed under the fluoroscopic guidance with an 18-gauge Seldinger needle and coaxial technique with a 8-10F drainage catheter. Among 10 patients with lung abscess, 8 patients improved by percutaneous catheter drainage. In one patient, drainage was failed by the accidental withdrawal of the catheter before complete drainage. One patient died of sepsis 5 hours after the procedure. Among three patients with complicated bulla, successful drainage was done in two patients, but in the remaining patient, the procedure was failed. In one patient with intrapulmonary bronchogenic cyst, the drainage was not successful due to the thick internal contents. In one patient with traumatic hematoma, after the drainage of old blood clots, the signs of infection disappeared. Overally, of 14 patients excluding one who died, 11 patients improved with percutaneous catheter drainage and three patients did not. There were no major complications during and after the procedure. We conclude that percutaneous catheter drainage is effective and safe procedure for the treatment of parenchymal fluid collections of the lung in patients unresponsive to the medical treatment.

  5. Nonholonomic catheter path reconstruction using electromagnetic tracking

    Science.gov (United States)

    Lugez, Elodie; Sadjadi, Hossein; Akl, Selim G.; Fichtinger, Gabor

    2015-03-01

    Catheter path reconstruction is a necessary step in many clinical procedures, such as cardiovascular interventions and high-dose-rate brachytherapy. To overcome limitations of standard imaging modalities, electromagnetic tracking has been employed to reconstruct catheter paths. However, tracking errors pose a challenge in accurate path reconstructions. We address this challenge by means of a filtering technique incorporating the electromagnetic measurements with the nonholonomic motion constraints of the sensor inside a catheter. The nonholonomic motion model of the sensor within the catheter and the electromagnetic measurement data were integrated using an extended Kalman filter. The performance of our proposed approach was experimentally evaluated using the Ascension's 3D Guidance trakStar electromagnetic tracker. Sensor measurements were recorded during insertions of an electromagnetic sensor (model 55) along ten predefined ground truth paths. Our method was implemented in MATLAB and applied to the measurement data. Our reconstruction results were compared to raw measurements as well as filtered measurements provided by the manufacturer. The mean of the root-mean-square (RMS) errors along the ten paths was 3.7 mm for the raw measurements, and 3.3 mm with manufacturer's filters. Our approach effectively reduced the mean RMS error to 2.7 mm. Compared to other filtering methods, our approach successfully improved the path reconstruction accuracy by exploiting the sensor's nonholonomic motion constraints in its formulation. Our approach seems promising for a variety of clinical procedures involving reconstruction of a catheter path.

  6. Complexity and demographic explanations of cumulative culture.

    Directory of Open Access Journals (Sweden)

    Adrien Querbes

    Full Text Available Formal models have linked prehistoric and historical instances of technological change (e.g., the Upper Paleolithic transition, cultural loss in Holocene Tasmania, scientific progress since the late nineteenth century to demographic change. According to these models, cumulation of technological complexity is inhibited by decreasing--while favoured by increasing--population levels. Here we show that these findings are contingent on how complexity is defined: demography plays a much more limited role in sustaining cumulative culture in case formal models deploy Herbert Simon's definition of complexity rather than the particular definitions of complexity hitherto assumed. Given that currently available empirical evidence doesn't afford discriminating proper from improper definitions of complexity, our robustness analyses put into question the force of recent demographic explanations of particular episodes of cultural change.

  7. Avoiding Program-Induced Cumulative Overload (PICO).

    Science.gov (United States)

    Orr, Robin; Knapik, Joseph J; Pope, Rodney

    2016-01-01

    This article defines the concept of program-induced cumulative overload (PICO), provides examples, and advises ways to mitigate the adverse effects. PICO is the excessive cumulative physical workload that can be imparted to military personnel by a military training program with an embedded physical training component. PICO can be acute (accumulating within a single day) or chronic (accumulating across the entirety of the program) and results in adverse outcomes for affected personnel, including detrimental fatigue, performance degradation, injuries, or illness. Strategies to mitigate PICO include focusing administration and logistic practices during the development and ongoing management of a trainee program and implementing known musculoskeletal injury prevention strategies. More training is not always better, and trainers need to consider the total amount of physical activity that military personnel experience across both operational training and physical training if PICO is to be mitigated.

  8. Sharing a quota on cumulative carbon emissions

    Science.gov (United States)

    Raupach, Michael R.; Davis, Steven J.; Peters, Glen P.; Andrew, Robbie M.; Canadell, Josep G.; Ciais, Philippe; Friedlingstein, Pierre; Jotzo, Frank; van Vuuren, Detlef P.; Le Quéré, Corinne

    2014-10-01

    Any limit on future global warming is associated with a quota on cumulative global CO2 emissions. We translate this global carbon quota to regional and national scales, on a spectrum of sharing principles that extends from continuation of the present distribution of emissions to an equal per-capita distribution of cumulative emissions. A blend of these endpoints emerges as the most viable option. For a carbon quota consistent with a 2 °C warming limit (relative to pre-industrial levels), the necessary long-term mitigation rates are very challenging (typically over 5% per year), both because of strong limits on future emissions from the global carbon quota and also the likely short-term persistence in emissions growth in many regions.

  9. Structural Vibration Monitoring Using Cumulative Spectral Analysis

    Directory of Open Access Journals (Sweden)

    Satoru Goto

    2013-01-01

    Full Text Available This paper describes a resonance decay estimation for structural health monitoring in the presence of nonstationary vibrations. In structural health monitoring, the structure's frequency response and resonant decay characteristics are very important for understanding how the structure changes. Cumulative spectral analysis (CSA estimates the frequency decay by using the impulse response. However, measuring the impulse response of buildings is impractical due to the need to shake the building itself. In a previous study, we reported on system damping monitoring using cumulative harmonic analysis (CHA, which is based on CSA. The current study describes scale model experiments on estimating the hidden resonance decay under non-stationary noise conditions by using CSA for structural condition monitoring.

  10. Cumulative carbon emissions and the Green Paradox

    OpenAIRE

    Ploeg, Frederick Van der

    2013-01-01

    The green paradox states that a gradually more ambitious climate policy such as a renewables subsidy or an anticipated carbon tax induces fossil fuel owners to extract more rapidly and accelerate global warming. However, if extraction becomes more costly as reserves are depleted, such policies also shorten the fossil fuel era, induce more fossil fuel to be left in the earth, and thus curb cumulative carbon emissions. These consequences are relevant, as global warming depends primarily on cumu...

  11. Impact of short-term hemodialysis catheters on the central veins: a catheter venographic study

    Energy Technology Data Exchange (ETDEWEB)

    Oguzkurt, Levent E-mail: loguzkurt@yahoo.com; Tercan, Fahri; Torun, Dilek; Yildirim, Tuelin; Zuemruetdal, Ayseguel; Kizilkilic, Osman

    2004-12-01

    Objective: To determine the incidence of pericatheter sleeve formation, thrombus formation, and stenosis of the central veins in hemodialysis patients with temporary catheters. Methods and material: In this prospective study, 57 patients (40 males, 17 females) with temporary dialysis catheters had catheter venography by pulling back the catheter just before removal. Patient's age range was 25-87 years (mean age, 51 years). The venographic studies were evaluated for pericatheter sleeve formation, thrombus formation, and stenosis of the brachiocephalic vein (BCV) and the superior vena cava (SVC). The IJV could only be evaluated if there was adequate filling during contrast administration. In a subgroup of patients who had had only right IJV or only right SCV catheters, impact of these catheters on the central veins was compared. Results: The catheter location was right internal jugular vein (IJV) in 26 cases, right subclavian vein (SCV) in 27 cases, left IJV in 1 case, and left SCV in 3 cases. Thirty-two patients (56%) had had only one temporary catheter and the rest had had more than one inserted. The mean dwell time for the catheters was 21 days (range 7-59 days). A pericatheter sleeve was detected on venography in 32 (56%) patients and thrombus formation was noted in 16 patients (28%). A total of 41 patients (72%) exhibited pericatheter sleeve and/or thrombus formation. While 19 of the 32 patients (59%) without previous catheterization had a sleeve around the catheter, only 13 (52%) of 25 patients who had had multiple catheters inserted had a sleeve (P>0.05). Of the eight patients (14%) with BCV stenosis, two had >50% stenosis. Only one patient (2%) had mild stenosis of the SVC. Three patients out of 15 (20%) who had diagnostic venography for the IJV had severe stenosis of the vein. Pericatheter sleeve formation was more frequent in women (P<0.05). However, there were no statistical differences with respect to pericatheter sleeve formation, luminal filling

  12. Expansive Soil Crack Depth under Cumulative Damage

    Directory of Open Access Journals (Sweden)

    Bei-xiao Shi

    2014-01-01

    Full Text Available The crack developing depth is a key problem to slope stability of the expansive soil and its project governance and the crack appears under the roles of dry-wet cycle and gradually develops. It is believed from the analysis that, because of its own cohesion, the expansive soil will have a certain amount of deformation under pulling stress but without cracks. The soil body will crack only when the deformation exceeds the ultimate tensile strain that causes cracks. And it is also believed that, due to the combined effect of various environmental factors, particularly changes of the internal water content, the inherent basic physical properties of expansive soil are weakened, and irreversible cumulative damages are eventually formed, resulting in the development of expansive soil cracks in depth. Starting from the perspective of volumetric strain that is caused by water loss, considering the influences of water loss rate and dry-wet cycle on crack developing depth, the crack developing depth calculation model which considers the water loss rate and the cumulative damages is established. Both the proposal of water loss rate and the application of cumulative damage theory to the expansive soil crack development problems try to avoid difficulties in matrix suction measurement, which will surely play a good role in promoting and improving the research of unsaturated expansive soil.

  13. EPA Workshop on Epigenetics and Cumulative Risk ...

    Science.gov (United States)

    Agenda Download the Workshop Agenda (PDF) The workshop included presentations and discussions by scientific experts pertaining to three topics (i.e., epigenetic changes associated with diverse stressors, key science considerations in understanding epigenetic changes, and practical application of epigenetic tools to address cumulative risks from environmental stressors), to address several questions under each topic, and included an opportunity for attendees to participate in break-out groups, provide comments and ask questions. Workshop Goals The workshop seeks to examine the opportunity for use of aggregate epigenetic change as an indicator in cumulative risk assessment for populations exposed to multiple stressors that affect epigenetic status. Epigenetic changes are specific molecular changes around DNA that alter expression of genes. Epigenetic changes include DNA methylation, formation of histone adducts, and changes in micro RNAs. Research today indicates that epigenetic changes are involved in many chronic diseases (cancer, cardiovascular disease, obesity, diabetes, mental health disorders, and asthma). Research has also linked a wide range of stressors including pollution and social factors with occurrence of epigenetic alterations. Epigenetic changes have the potential to reflect impacts of risk factors across multiple stages of life. Only recently receiving attention is the nexus between the factors of cumulative exposure to environmental

  14. Nuestra experiencia con el catéter autoposicionante frente a otras variantes del catéter Tenckhoff: Estudio multicéntrico Our experience with the self-locating catheter compared to other variants of the Tenckhoff catheter: Multicentre study

    Directory of Open Access Journals (Sweden)

    Francisco Cirera Segura

    2012-12-01

    Full Text Available Introducción: El objetivo del estudio fue comparar las complicaciones quirúrgicas, mecánicas e infecciosas que presenta el catéter autoposicionante frente a otros tipos de catéteres tipo Tenckhoff, así como comparar la supervivencia de ambos tipos de catéteres. Material y métodos: Estudio descriptivo retrospectivo multicéntrico, de 79 meses de duración. Se estudiaron todos los catéteres colocados en dos unidades de diálisis peritoneal. El análisis se realizó con el paquete estadístico IBM SPSS Statistics 19.0, estableciendo el nivel de significación en pIntroduction: The aim of the study was to compare the surgical, mechanical and infectious complications presented by self-locating catheters compared to other types of Tenckhoff catheters, and to compare the survival of both types of catheter. Material and methods: Multicentre retrospective descriptive study lasting 79 months. All the catheters placed in two peritoneal dialysis units were studied. The analysis was carried out using the IBM SPSS Statistics 19.0 statistical package, setting the significance level at p<0.05. Results: The sample was made up of 241 catheters in 202 patients, of whom 52.5% were men (n=106. The average age was 61.98 + 15.87 years. The most used catheter was the self-locating catheter with 63.5% (n=153. Surgical complications. Surgical complications were only described in 28.1% of the self-locating catheters (p<0.001. Mechanical complications. These were more frequent with the self-locating catheter, except for displacement, and were only significant for leaks (p=0.003. Infections. A total of 196 peritoneal infections took place in 116 catheters, with a rate of 0.691 + 0.87 episode per patient per year. Of these, 45.1% occurred in self-locating catheters, with no significant differences (p=0.214. Causes for withdrawal. Leaving PD represented 45.6% of the catheter withdrawals, 10% were due to peritoneal infection and 6.6% due to incorrect function. The

  15. Catheter embolization from implanted venous access devices: case reports.

    Science.gov (United States)

    Carr, M E

    1989-04-01

    Two cases of catheter embolization from implanted venous access devices are reported and the available literature is reviewed. The catheter from an implanted venous access device migrated into the right heart after slippage of the O-ring, which attaches the catheter to the infusion port. The distal 6 cm of an infusion port catheter embolized to the right heart after spontaneous fracture of the catheter at the point where it passed between the clavicle and first rib. Both catheters were removed percutaneously without complication. Risk factors for embolization were apparent on x-ray films with evidence of O-ring slippage in 1 case an obvious kinking of the catheter in the other. Symptoms of embolization included chest discomfort, right upper quadrant pain, and nausea. In 1 case, an extra heart sound, initially thought to be an S3, disappeared when the catheter was removed.

  16. Microbiocidal effects of various taurolidine containing catheter lock solutions

    NARCIS (Netherlands)

    Olthof, E.D.; Nijland, R van; Gulich, A.F.; Wanten, G.J.A.

    2015-01-01

    BACKGROUND & AIMS: We have recently shown that a catheter lock solution containing taurolidine dramatically decreases catheter-related bloodstream infections (CRBSI) in patients on home parenteral nutrition (HPN) when compared to heparin. Since several taurolidine formulations are commercially avail

  17. A novel method for salvage of malfunctioning peritoneal dialysis catheter

    Directory of Open Access Journals (Sweden)

    Ali Akbar Beig

    2014-01-01

    Conclusions: Comparing the advantages and disadvantages of this method to the previous laparoscopically repaired catheter, we concluded that this new method is efficient, and is a suitable way for malfunctioning PD catheter salvage.

  18. Risk factors for peritoneal dialysis catheter failure in children ...

    African Journals Online (AJOL)

    Risk factors for peritoneal dialysis catheter failure in children. ... tertiary Children's Hospital, King Fahad Medical City, Riyadh, Saudi Arabia, from January ... improvement of patients' nutritional status, use of a swan-neck double-cuffed catheter, ...

  19. Prevention of catheter-related Pseudomonas aeruginosa infection by levofloxacin-impregnated catheters in vitro and in vivo

    Institute of Scientific and Technical Information of China (English)

    Yan Ping; Liu Wei; Kong Jinliang; Wu Hong; Chen Yiqiang

    2014-01-01

    Background Implanted medical catheter-related infections are increasing,hence a need for developing catheter polymers bonded to antimicrobials.We evaluated preventive effects of levofloxacin-impregnated catheters in catheterrelated Psuedomonas aeruginosa (strain PAO1) infection.Methods Drug release from levofloxacin-impregnated catheters was measured in vitro.Levofloxacin-impregnated catheters and polyvinyl chloride (PVC) catheters were immersed in 5 ml 50% Luria Bertani medium containing 108 CFU/ml Pseudomonas aeruginosa then incubated for 6,12,24 or 48 hours at 37℃ when bacteria adhering to the catheters and bacteria in the growth culture medium were determined.Impregnated and PVC catheters were singly implanted subcutaneously in mice,50 μl (107CFU) of PAO1 was injected into catheters.After the first and fifth days challenge,bacterial counts on implanted catheters and in surrounding tissues were determined microbiologically.Bacterial colonization and biofilm formation on implanted catheters were assessed by scanning electron microscopy.Results Drug release from levofloxacin-impregnated catheters was rapid.Levofloxacin-impregnated catheters had significantly fewer bacteria compared to PVC in vitro.After first and fifth day of challenge,no or significantly fewer bacteria adhered to impregnated catheters or in surrounding tissues compared to PVC.Scanning electron microscopical images after first day displayed from none to significantly fewer bacteria adhering to impregnated implanted catheters,compared to bacteria and microcolonies adhering to PVC catheters.After the fifth day,no bacteria were found on impregnated catheters,compared to clusters surrounding mucus-like substance and coral-shaped biofilms with polymorphonuclear leukocyte on PVC catheters.After the first day of challenge,secretion occurred in all implanted catheters with surrounding tissues mildly hyperaemic and swollen.After the fifth day,minute secretions inside impregnated catheters and no

  20. [Medial venous catheter or midline (MVC)].

    Science.gov (United States)

    Carrero Caballero, Ma Carmen; Montealegre Sanz, María; Cubero Pérez, Ma Antonia

    2014-01-01

    Current clinical practice is characterised for importance of the patient's quality of life and the need to reduce the costs of their treatment. We search intravenous therapy alternatives that meet the needs of the patient, reducing the complications associated with the use of venous catheters. Scientific evidence shows that there are midline venous catheters that offer patients and professionals the possibility of extending the duration of infusion therapy, using more venous compatibility materials, and with less risk of infection. The Midlines are becoming in a safe an efficient device for intravenous therapy, continuous and intermittent infusion, provided the necessary care by expert nurses. Midline catheters are peripheral venous access devices between 3 to 10 inches in length (8 to 25 cm). Midlines are usually placed in an upper arm vein, such as the brachial or cephalic, and the distal extreme ends below the level of the axillary line. Midlines catheters implanted in the cephalic or deep basilica veins get more blood flow. This large blood volume justifies the lower risk of mechanical or chemical phlebitis. Midlines are routinely used for two to six weeks. Due that the extrem of these catheters does not extend beyond the axillary line, there are limitations for its use: type of infused drugs, velocity of infusion, etc. In general, solutions that have pH 5 to 9, or an osmolarity less than 500 mOsm are appropriate for infusion through a Midline. Its use is recommended in case of treatments over 7 days with low irritant capacity fluids. According to the Infusion Nurses Society's standards of practice, Midline catheters are appropriate for all intravenous fluids that would normally be administered through a short peripheral IV Importantly, due that the catheter does not pass through the central veins, Midlines can be placed without a chest X-ray to confirm placement. For certain situations, Midlines are suitable for acute units and even for care home settings

  1. Urinary catheterization diary – A useful tool in tracking causes of non-deflating Foley catheter

    Directory of Open Access Journals (Sweden)

    C.O. Okorie

    2015-06-01

    Conclusions: Most urinary catheters marketed in developing countries are unidentifiable after unpacking. A catheterization diary is a useful tool for solving catheter-related problems, and its application in health-care facilities should be encouraged. Companies marketing Foley catheters should print the catheter name on both the catheter packaging and on the catheter itself.

  2. 21 CFR 878.4200 - Introduction/drainage catheter and accessories.

    Science.gov (United States)

    2010-04-01

    ... catheters (including dialysis), and other general surgical catheters. An introduction/drainage catheter... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Introduction/drainage catheter and accessories... Introduction/drainage catheter and accessories. (a) Identification. An introduction/drainage catheter is a...

  3. 21 CFR 870.1230 - Fiberoptic oximeter catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Fiberoptic oximeter catheter. 870.1230 Section 870...) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1230 Fiberoptic oximeter catheter. (a) Identification. A fiberoptic oximeter catheter is a device used to estimate the...

  4. 21 CFR 868.6810 - Tracheobronchial suction catheter.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Tracheobronchial suction catheter. 868.6810... (CONTINUED) MEDICAL DEVICES ANESTHESIOLOGY DEVICES Miscellaneous § 868.6810 Tracheobronchial suction catheter. (a) Identification. A tracheobronchial suction catheter is a device used to aspirate liquids or...

  5. Hospital-wide multidisciplinary, multimodal intervention programme to reduce central venous catheter-associated bloodstream infection.

    Directory of Open Access Journals (Sweden)

    Walter Zingg

    Full Text Available Central line-associated bloodstream infection (CLABSI is the major complication of central venous catheters (CVC. The aim of the study was to test the effectiveness of a hospital-wide strategy on CLABSI reduction. Between 2008 and 2011, all CVCs were observed individually and hospital-wide at a large university-affiliated, tertiary care hospital. CVC insertion training started from the 3rd quarter and a total of 146 physicians employed or newly entering the hospital were trained in simulator workshops. CVC care started from quarter 7 and a total of 1274 nurses were trained by their supervisors using a web-based, modular, e-learning programme. The study included 3952 patients with 6353 CVCs accumulating 61,366 catheter-days. Hospital-wide, 106 patients had 114 CLABSIs with a cumulative incidence of 1.79 infections per 100 catheters. We observed a significant quarterly reduction of the incidence density (incidence rate ratios [95% confidence interval]: 0.92 [0.88-0.96]; P<0.001 after adjusting for multiple confounders. The incidence densities (n/1000 catheter-days in the first and last study year were 2.3/1000 and 0.7/1000 hospital-wide, 1.7/1000 and 0.4/1000 in the intensive care units, and 2.7/1000 and 0.9/1000 in non-intensive care settings, respectively. Median time-to-infection was 15 days (Interquartile range, 8-22. Our findings suggest that clinically relevant reduction of hospital-wide CLABSI was reached with a comprehensive, multidisciplinary and multimodal quality improvement programme including aspects of behavioural change and key principles of good implementation practice. This is one of the first multimodal, multidisciplinary, hospital-wide training strategies successfully reducing CLABSI.

  6. Catheter Removal versus Retention in the Management of Catheter-Associated Enterococcal Bloodstream Infections

    Directory of Open Access Journals (Sweden)

    Jonas Marschall

    2013-01-01

    Full Text Available BACKGROUND: Enterococci are an important cause of central venous catheter (CVC-associated bloodstream infections (CA-BSI. It is unclear whether CVC removal is necessary to successfully manage enterococcal CA-BSI.

  7. Cumulative risks of foster care placement for Danish children

    National Research Council Canada - National Science Library

    Fallesen, Peter; Emanuel, Natalia; Wildeman, Christopher

    2014-01-01

    Although recent research suggests that the cumulative risk of foster care placement is far higher for American children than originally suspected, little is known about the cumulative risk of foster...

  8. Recursive Numerical Evaluation of the Cumulative Bivariate Normal Distribution

    CERN Document Server

    Meyer, Christian

    2010-01-01

    We propose an algorithm for evaluation of the cumulative bivariate normal distribution, building upon Marsaglia's ideas for evaluation of the cumulative univariate normal distribution. The algorithm is mathematically transparent, delivers competitive performance and can easily be extended to arbitrary precision.

  9. Climate mitigation: sustainable preferences and cumulative carbon

    Science.gov (United States)

    Buckle, Simon

    2010-05-01

    We develop a stylized AK growth model with both climate damages to ecosystem goods and services and sustainable preferences that allow trade-offs between present discounted utility and long-run climate damages. The simplicity of the model permits analytical solutions. Concern for the long-term provides a strong driver for mitigation action. One plausible specification of sustainable preferences leads to the result that, for a range of initial parameter values, an optimizing agent would choose a level of cumulative carbon dioxide (CO2) emissions independent of initial production capital endowment and CO2 levels. There is no technological change so, for economies with sufficiently high initial capital and CO2 endowments, optimal mitigation will lead to disinvestment. For lower values of initial capital and/or CO2 levels, positive investment can be optimal, but still within the same overall level of cumulative emissions. One striking aspect of the model is the complexity of possible outcomes, in addition to these optimal solutions. We also identify a resource constrained region and several regions where climate damages exceed resources available for consumption. Other specifications of sustainable preferences are discussed, as is the case of a hard constraint on long-run damages. Scientists are currently highlighting the potential importance of the cumulative carbon emissions concept as a robust yet flexible target for climate policymakers. This paper shows that it also has an ethical interpretation: it embodies an implicit trade off in global welfare between present discounted welfare and long-term climate damages. We hope that further development of the ideas presented here might contribute to the research and policy debate on the critical areas of intra- and intergenerational welfare.

  10. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter.

    Science.gov (United States)

    Chuang, Ming-Tsung; Wu, Ding-Kwo; Chang, Cheng-Ang; Shih, Ming-Chen Paul; Ou-Yang, Fu; Chuang, Chien-Han; Tsai, Yi-Fan; Hsu, Jui-Sheng

    2011-11-01

    The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010), a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days). The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days). All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  11. Concurrent use of pigtail and loop snare catheters for percutaneous retrieval of dislodged central venous port catheter

    Directory of Open Access Journals (Sweden)

    Ming-Tsung Chuang

    2011-11-01

    Full Text Available The purpose of this study was to report our experience of percutaneous retrieval of dislodged port catheters with concurrent use of pigtail and loop snare catheters. During a 5-year period at our institute (June 2005 to July 2010, a total of 23 dislodged port catheters were retrieved. The interval between port catheter implantation and dislodged catheter retrieval ranged from 43 days to 1,414 days (mean 586.7 days. The time of delayed retrieval ranged from 1 day to 45 days (mean 4.6 days. All dislodged catheters were retrieved with the concurrent use of pigtail and loop snare catheters via femoral venous route. The prevalence of port catheter dislodgement at our institute was 3.4%. All dislodged port catheters were removed successfully with pigtail and loop snare catheters together. No procedure-related complications were encountered, except for transient arrhythmia in two patients, which required no medication. In conclusion, the concurrent use of pigtail and loop snare catheters is a feasible and easy way for percutaneous retrieval of a dislodged central venous port catheter.

  12. Complications after placement of peritoneal catheter

    Directory of Open Access Journals (Sweden)

    Đurđević-Mirković Tatjana

    2011-01-01

    Full Text Available Introduction. Peritoneal dialysis is one of the modalities used for treatment of end-stage chronic kidney failure. Nowadays, this method is complementary to haemodialysis and renal transplantation. Owing to the rich vascularization of the peritoneum, it is used in the processes of osmosis and diffusion, enabling the removal of uremic material from the body. The procedure includes introduction of peritoneal fluid via the peritoneal catheter. Complications. The catheter is placed through the anterior abdominal wall with its tip positioned in the small pelvis. There are several techniques for catheter placement considered minimally invasive, which, however, may be associated with various complications. These complications can be divided into mechanical (catheter dysfunction, cuff protrusion, hernia, dialysate leaks, visceral perforation and infectious (early peritonitis, exit site or tunnel infection, surgical wounds. In most cases, such complications are rare and can be successfully managed using conservative therapy; however, in some situations severe complications can endanger the life of the patient. On-time recognition of complications, particularly in patients at risk, is of paramount importance for an effective treatment. The development of complications can increase the morbidity and the chance of treatment failure, and therefore transfer to haemodialysis. Conclusion. The preoperative evaluation and determination of the risk factors as well as the early recognition and adequate management of complications are essential in their prevention.

  13. Best practices in urinary catheter care.

    Science.gov (United States)

    Herter, Rebecca; Kazer, Meredith Wallace

    2010-06-01

    Urinary catheterization is a common healthcare intervention used to manage urinary dysfunction that poses serious associated risks and complications. This article discusses methods of urinary catheterization and their indications, catheter-associated complications, and assessment and management strategies that home healthcare practitioners can employ to ensure best patient outcomes and minimize complications.

  14. [Femoral venous catheter: an unusual complication].

    Science.gov (United States)

    Garcia, P; Mora, A; Trambert, P; Maler, E; Courant, P

    2000-08-01

    We report an erratic course of a venous femoral catheter which was in the abdominal cavity in a patient with an haemoperitoneum and an hepatic injury. This complication led to an inefficiency of the transfusion and a worsening of the haemoperitoneum.

  15. A multicentre comparative evaluation of catheter valves.

    Science.gov (United States)

    Fader, M; Pettersson, L; Brooks, R; Dean, G; Wells, M; Cottenden, A; Malone-Lee, J

    Catheter valves are an alternative to leg bags for urine drainage, but no studies have yet been published which have compared the performance of different valves. This study was undertaken to evaluate the performance of the seven catheter valves available on the UK market in April 1996. The study was carried out by the Continence Products Evaluation (CPE) Network funded by the Medical Devices Agency (Department of Health). Each valve type was tested for 1 week by 19-36 cognitively unimpaired and manually dextrous subjects recruited from 11 test centres. At the end of each week, subjects completed an evaluation form (based on a three-point rating scale) to record product performance. The same catheter valves were also tested for ease of opening/closing by 33 subjects (mostly catheter users) who had some manual impairment. Performance scores varied widely between products. It was found that, to be successful, a valve needs to be easy to manipulate, leak-free, comfortable and inconspicuous. Prescribers need to be aware of the strengths and limitations of different valves for appropriate product selection.

  16. Long and Short Term Cumulative Structural Priming Effects

    OpenAIRE

    Kaschak, Michael P.; Kutta, Timothy J.; Coyle, Jacqueline M.

    2012-01-01

    We present six experiments that examine cumulative structural priming effects (i.e., structural priming effects that accumulate across many utterances). Of particular interest is whether (1) cumulative priming effects transfer across language production tasks and (2) the transfer of cumulative priming effects across tasks persists over the course of a week. Our data suggest that cumulative structural priming effects do transfer across language production tasks (e.g., from written stem complet...

  17. Preserved cumulative semantic interference despite amnesia

    Directory of Open Access Journals (Sweden)

    Gary Michael Oppenheim

    2015-05-01

    As predicted by Oppenheim et al’s (2010 implicit incremental learning account, WRP’s BCN RTs demonstrated strong (and significant repetition priming and semantic blocking effects (Figure 1. Similar to typical results from neurally intact undergraduates, WRP took longer to name pictures presented in semantically homogeneous blocks than in heterogeneous blocks, an effect that increased with each cycle. This result challenges accounts that ascribe cumulative semantic interference in this task to explicit memory mechanisms, instead suggesting that the effect has the sort of implicit learning bases that are typically spared in hippocampal amnesia.

  18. Cumulant matching for independent source extraction.

    Science.gov (United States)

    Phlypo, Ronald; Zarzoso, Vicente; Comon, Pierre; Lemahieu, Ignace

    2008-01-01

    In this work we show how one can make use of priors on signal statistics under the form of cumulant guesses to extract an independent source from an observed mixture. The advantage of using statistical priors on the signal lies in the fact that no specific knowledge is needed about its temporal behavior, neither about its spatial distribution. We show that these statistics can be obtained either by reasoning on the theoretical values of a supposed waveform, either by using a subset of the observations from which we know that their statistics are merely hindered by interferences. Results on an electro-cardiographic recording confirm the above assumptions.

  19. Flexible parametric modelling of cause-specific hazards to estimate cumulative incidence functions

    Science.gov (United States)

    2013-01-01

    Background Competing risks are a common occurrence in survival analysis. They arise when a patient is at risk of more than one mutually exclusive event, such as death from different causes, and the occurrence of one of these may prevent any other event from ever happening. Methods There are two main approaches to modelling competing risks: the first is to model the cause-specific hazards and transform these to the cumulative incidence function; the second is to model directly on a transformation of the cumulative incidence function. We focus on the first approach in this paper. This paper advocates the use of the flexible parametric survival model in this competing risk framework. Results An illustrative example on the survival of breast cancer patients has shown that the flexible parametric proportional hazards model has almost perfect agreement with the Cox proportional hazards model. However, the large epidemiological data set used here shows clear evidence of non-proportional hazards. The flexible parametric model is able to adequately account for these through the incorporation of time-dependent effects. Conclusion A key advantage of using this approach is that smooth estimates of both the cause-specific hazard rates and the cumulative incidence functions can be obtained. It is also relatively easy to incorporate time-dependent effects which are commonly seen in epidemiological studies. PMID:23384310

  20. Epidural catheter fragment entrapment: a case report

    Directory of Open Access Journals (Sweden)

    Mohammadi M

    2010-07-01

    Full Text Available "n Normal 0 false false false EN-US X-NONE AR-SA MicrosoftInternetExplorer4 st1":*{behavior:url(#ieooui } /* Style Definitions */ table.MsoNormalTable {mso-style-name:"Table Normal"; mso-tstyle-rowband-size:0; mso-tstyle-colband-size:0; mso-style-noshow:yes; mso-style-priority:99; mso-style-qformat:yes; mso-style-parent:""; mso-padding-alt:0cm 5.4pt 0cm 5.4pt; mso-para-margin:0cm; mso-para-margin-bottom:.0001pt; mso-pagination:widow-orphan; font-size:11.0pt; font-family:"Calibri","sans-serif"; mso-ascii-font-family:Calibri; mso-ascii-theme-font:minor-latin; mso-fareast-font-family:"Times New Roman"; mso-fareast-theme-font:minor-fareast; mso-hansi-font-family:Calibri; mso-hansi-theme-font:minor-latin; mso-bidi-font-family:Arial; mso-bidi-theme-font:minor-bidi;} Background: Epidural catheters are seldom difficult to remove from patients. The breakage of the catheters is uncommon, troublesome and occasionally dangerous. "n"nCase presentation: A lumbar epidural catheter inserted in a 17 year-old man for applying anesthesia for internal fixation of femur fracture and subsequent postoperative epidural analgesia. In the third postoperative day, during unsuccessful attempt for removing the catheter, it was broken and was retained in his back. A CT- scan was performed and shows a fragment of catheter in the sub- laminar ligament between L3 and L4 without any connection with epidural space. As the patient had no complaint the fractured fragment was left in site and he was just followed up in the clinic."n"nConclusion: The knowledge of practical method in locating the retained epidural catheter, and the indication for surgical removal are very important. CT- scan is useful in showing the mechanism and locating the epidural catheter entrapment and facilitating surgical follow-up.

  1. Urethral catheters: can we reduce use?

    Directory of Open Access Journals (Sweden)

    van den Akker-van Marle M Elske

    2011-05-01

    Full Text Available Abstract Background Indwelling urinary catheters are the main cause of healthcare-associated urinary tract infections. It can be expected that reduction of the use of urinary catheters will lead to decreased numbers of urinary tract infection. Methods The efficacy of an intervention programme to improve adherence to recommendations to reduce the use of urethral catheters was studied in a before-after comparison in ten Dutch hospitals. The programme detected barriers and facilitators and each individual facility was supported with developing their own intervention strategy. Outcome was evaluated by the prevalence of catheters, alternatives such as diapers, numbers of urinary tract infections, the percentage of correct indications and the duration of catheterization. The costs of the implementation as well as the catheterization were evaluated. Results Of a population of 16,495 hospitalized patients 3335 patients of whom 2943 were evaluable for the study, had a urethral catheter. The prevalence of urethral catheters decreased insignificantly in neurology (OR 0.93; 95% CI 0.77 - 1.13 and internal medicine wards (OR 0.97; 95% CI 0.83 - 1.13, decreased significantly in surgical wards (OR 0.84; 95% CI 0.75 - 0.96, but increased significantly in intensive care (IC and coronary care (CC units (OR 1.48; 95% CI 1.01 - 2.17. The use of alternatives was limited and remained so after the intervention. Duration of catheterization decreased insignificantly in IC/CC units (ratio after/before 0.95; 95% CI 0.78 - 1.16 and neurology (ratio 0.97; 95% CI 0.80 - 1.18 and significantly in internal medicine (ratio 0.81; 95% CI 0.69 - 0.96 and surgery wards (ratio 0.80; 95% CI 0.71 - 0.90. The percentage of correct indications on the day of inclusion increased from 50 to 67% (p Conclusion Targeted implementation of recommendations from an existing guideline can lead to better adherence and cost savings. Especially, hospitals which use a lot of urethral catheters or

  2. A randomised controlled trial of Heparin versus EthAnol Lock THerapY for the prevention of Catheter Associated infecTion in Haemodialysis patients – the HEALTHY-CATH trial

    Directory of Open Access Journals (Sweden)

    Broom Jennifer K

    2012-11-01

    Full Text Available Abstract Background Tunnelled central venous dialysis catheter use is significantly limited by the occurrence of catheter-related infections. This randomised controlled trial assessed the efficacy of a 48 hour 70% ethanol lock vs heparin locks in prolonging the time to the first episode of catheter related blood stream infection (CRBSI. Methods Patients undergoing haemodialysis (HD via a tunnelled catheter were randomised 1:1 to once per week ethanol locks (with two heparin locks between other dialysis sessions vs thrice per week heparin locks. Results Observed catheter days in the heparin (n=24 and ethanol (n=25 groups were 1814 and 3614 respectively. CRBSI occurred at a rate of 0.85 vs. 0.28 per 1000 catheter days in the heparin vs ethanol group by intention to treat analysis (incident rate ratio (IRR for ethanol vs. heparin 0.17; 95%CI 0.02-1.63; p=0.12. Flow issues requiring catheter removal occurred at a rate of 1.6 vs 1.4 per 1000 catheter days in the heparin and ethanol groups respectively (IRR 0.85; 95% CI 0.20-3.5 p =0.82 (for ethanol vs heparin. Conclusions Catheter survival and catheter-related blood stream infection were not significantly different but there was a trend towards a reduced rate of infection in the ethanol group. This study establishes proof of concept and will inform an adequately powered multicentre trial to definitively examine the efficacy and safety of ethanol locks as an alternative to current therapies used in the prevention of catheter-associated blood stream infections in patients dialysing with tunnelled catheters. Trial Registration Australian New Zealand Clinical Trials Registry ACTRN12609000493246

  3. A Missing Link in the Evolution of the Cumulative Recorder

    Science.gov (United States)

    Asano, Toshio; Lattal, Kennon A.

    2012-01-01

    A recently recovered cumulative recorder provides a missing link in the evolution of the cumulative recorder from a modified kymograph to a reliably operating, scientifically and commercially successful instrument. The recorder, the only physical evidence of such an early precommercial cumulative recorder yet found, was sent to Keio University in…

  4. Original and cumulative prospect theory: a discussion of empirical differences

    NARCIS (Netherlands)

    P.P. Wakker; H. Fennema

    1997-01-01

    This note discusses differences between prospect theory and cumulative prospect theory. It shows that cumulative prospect theory is not merely a formal correction of some theoretical problems in prospect theory, but it also gives different predictions. Experiments are described that favor cumulative

  5. Repositioning of malpositioned or flipped central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Thalhammer, A.; Jacobi, V.; Balzer, J.; Vogl, T.J. [Institute for Diagnostic and Interventional Radiology, Central Radiology Clinic, J.W. Goethe University, Frankfurt am Main (Germany)

    2002-03-01

    Primary misplaced or secondary flipped implanted catheters are located mostly in the right jugular vein. We demonstrate an effective method to replace fix implanted catheters such as Ports, Grochomg or Hickman catheters. Using a femoral venous approach, replacement into the superior vena cava can easily be done with a Sidewinder 1 catheter which is hooked over the misplaced central venous approach. In all our patients the method was successful. The repositioning technique described is simple, fast and has low costs. We can keep sterile conditions and do not need to solve the catheters' fixation. (orig.)

  6. Balloon angioplasty for disruption of tunneled dialysis catheter fibrin sheath.

    Science.gov (United States)

    Watorek, Ewa; Golebiowski, Tomasz; Letachowicz, Krzysztof; Garcarek, Jerzy; Kurcz, Jacek; Bartosik, Hanna Augustyniak; Letachowicz, Waldemar; Weyde, Waclaw; Klinger, Marian

    2012-01-01

    Management of failing tunneled hemodialysis catheters, sometimes the only vascular access for hemodialysis, presents a difficult problem. In spite of various techniques having been developed, no consensus has been reached about the preferred technique, associated with the longest catheter patency. We report disruption of the fibrin sheath covering dysfunctional tunneled hemodialysis catheter by means of angioplasty, followed by over guidewire catheter exchange. Following the procedure, the catheter placed in the recovered lumen of the vessel presented correct function. The described procedure allowed maintenance of vascular access in our patient. Additionally, dilatation of the concomitant central vein stenosis opens an option for another attempt for arteriovenous fistula creation.

  7. Cumulative Environmental Management Association : Wood Buffalo Region

    Energy Technology Data Exchange (ETDEWEB)

    Friesen, B. [Syncrude Canada Ltd., Edmonton, AB (Canada)

    2001-07-01

    The recently announced oil sands development of the Wood Buffalo Region in Alberta was the focus of this power point presentation. Both mining and in situ development is expected to total $26 billion and 2.6 million barrels per day of bitumen production. This paper described the economic, social and environmental challenges facing the resource development of this region. In addition to the proposed oil sands projects, this region will accommodate the needs of conventional oil and gas production, forestry, building of pipelines and power lines, municipal development, recreation, tourism, mining exploration and open cast mining. The Cumulative Environmental Management Association (CEMA) was inaugurated as a non-profit association in April 2000, and includes 41 members from all sectors. Its major role is to ensure a sustainable ecosystem and to avoid any cumulative impacts on wildlife. Other work underway includes the study of soil and plant species diversity, and the effects of air emissions on human health, wildlife and vegetation. The bioaccumulation of heavy metals and their impacts on surface water and fish is also under consideration to ensure the quality and quantity of surface water and ground water. 3 figs.

  8. Cumulative environmental management and the oil sands

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2005-07-01

    In response to concerns regarding the cumulative environmental impacts of oil sands development within the Athabasca oil sands deposit, the government of Alberta established a Regional Sustainable Development Strategy (RSDS) to balance development with environmental protection. The environmental issues identified through the RSDS were addressed by the Cumulative Environmental Management Association (CEMA). CEMA's boundary is the Wood Buffalo region of northeastern Alberta. It identifies existing and future environmental effects in the region and proposes recommendations to regulatory bodies for reducing environmental impacts associated with oil sands development. This presentation outlined some of the 55 stakeholder representatives of CEMA, including Alberta government departments associated with resource development, oil sand developers within the region, and Aboriginal communities and First Nations. These stakeholders provide input on sector priorities and agree on environmental thresholds. Established working groups also address technical and scientific research issues identified in the RSDS such as sustainable ecosystems; surface waters; trace metals and air contaminants; nitrogen oxides and sulphur dioxides; and land reclamation. To date, CEMA has submitted more than 50 reports and has made 4 major environmental recommendations for trace metal management, ecosystem management tools, a framework for acid deposition management, and a landscape design checklist. tabs., figs.

  9. Higher Order Cumulants in Colorless Partonic Plasma

    CERN Document Server

    Cherif, S; Ladrem, M

    2016-01-01

    Any physical system considered to study the QCD deconfinement phase transition certainly has a finite volume, so the finite size effects are inevitably present. This renders the location of the phase transition and the determination of its order as an extremely difficult task, even in the simplest known cases. In order to identify and locate the colorless QCD deconfinement transition point in finite volume $T_{0}(V)$, a new approach based on the finite-size cumulant expansion of the order parameter and the $\\mathscr{L}_{m,n}$-Method is used.We have shown that both cumulants of higher order and their ratios, associated to the thermodynamical fluctuations of the order parameter, in QCD deconfinement phase transition behave in a particular enough way revealing pronounced oscillations in the transition region. The sign structure and the oscillatory behavior of these in the vicinity of the deconfinement phase transition point might be a sensitive probe and may allow one to elucidate their relation to the QCD phase...

  10. Innovativeness, population size and cumulative cultural evolution.

    Science.gov (United States)

    Kobayashi, Yutaka; Aoki, Kenichi

    2012-08-01

    Henrich [Henrich, J., 2004. Demography and cultural evolution: how adaptive cultural processes can produce maladaptive losses-the Tasmanian case. Am. Antiquity 69, 197-214] proposed a model designed to show that larger population size facilitates cumulative cultural evolution toward higher skill levels. In this model, each newborn attempts to imitate the most highly skilled individual of the parental generation by directly-biased social learning, but the skill level he/she acquires deviates probabilistically from that of the exemplar (cultural parent). The probability that the skill level of the imitator exceeds that of the exemplar can be regarded as the innovation rate. After reformulating Henrich's model rigorously, we introduce an overlapping-generations analog based on the Moran model and derive an approximate formula for the expected change per generation of the highest skill level in the population. For large population size, our overlapping-generations model predicts a much larger effect of population size than Henrich's discrete-generations model. We then investigate by way of Monte Carlo simulations the case where each newborn chooses as his/her exemplar the most highly skilled individual from among a limited number of acquaintances. When the number of acquaintances is small relative to the population size, we find that a change in the innovation rate contributes more than a proportional change in population size to the cumulative cultural evolution of skill level.

  11. Peritoneal dialysis catheter placement as a mode of renal replacement therapy: Long-term results from a tertiary academic institution.

    Science.gov (United States)

    Haskins, Ivy N; Schreiber, Martin; Prabhu, Ajita S; Krpata, David M; Perez, Arielle J; Tastaldi, Luciano; Tu, Chao; Rosen, Michael J; Rosenblatt, Steven

    2017-08-31

    Peritoneal dialysis as a mode of renal replacement therapy still has not been embraced widely as an alternative to hemodialysis. Furthermore, there is marked variability in peritoneal dialysis catheter insertion techniques and perioperative management within the United States. After the publication of best-demonstrated practices for peritoneal dialysis catheter placement, the utilization of peritoneal dialysis has increased significantly at our institution. We detail the long-term success of peritoneal dialysis catheter placement after the adoption of best-demonstrated practices. Retrospective chart review was performed on all patients who underwent laparoscopic peritoneal dialysis catheter placement using the best-demonstrated practice technique from January 2005 through December 2015. Preoperative patient demographic information, intraoperative variables, 30-day morbidity and mortality, and long-term catheter durability outcomes were investigated. A total of 457 patients met inclusion criteria. Four (0.9%) patients experienced an immediate postoperative complication requiring return to the operating room. There were no perioperative mortalities. A total of 298 (65.2%) patients were available for long-term follow-up; 221 (74.2%) patients are still alive, 76 (25.6%) patients are still undergoing peritoneal dialysis, 63 (21.1%) patients transitioned from peritoneal dialysis to hemodialysis, and 88 (29.5%) patients have undergone kidney transplantation. Based on Kaplan-Meier survival plots, 30% of patients will transition from peritoneal dialysis to hemodialysis after 5.5 years of peritoneal dialysis and the median time from commencing peritoneal dialysis to kidney transplantation is 5.6 years. Based on our institutional data, the adoption of best-demonstrated practices should provide long-term and reliable access to the peritoneal cavity. We recommend the adoption of these techniques to facilitate long-term peritoneal dialysis catheter survival. Copyright © 2017

  12. The bowed catheter sign: a risk for pericardial tamponade

    Energy Technology Data Exchange (ETDEWEB)

    Towbin, Richard [Phoenix Children' s Hospital, Department of Radiology, Phoenix, AZ (United States)

    2008-03-15

    The use of a central venous catheter (CVC) has become commonplace in the care of children with a wide variety of medical and surgical problems. Complications resulting from the insertion of these catheters are well recognized and can be life-threatening. When a temporary CVC or other catheter is inserted into the central venous system it is secured to the skin with a combination of sutures and sterile dressing. This fixes the catheter in place and does not allow it to retract, thereby putting pressure on the right atrial wall via the catheter tip if it is too long. The probability of wall penetration is increased if a catheter or device is tapered at the point of contact. The purpose of this case report is to present the bowed catheter sign and to review the anatomy of the cavotricuspid isthmus, a possible predisposing factor to cardiac perforation and tamponade. (orig.)

  13. Catheter valves: a welcome alternative to leg bags.

    Science.gov (United States)

    Woodward, Sue

    Catheterisation is commonly used to manage long-term bladder drainage. If intermittent catheterisation is not possible an indwelling urethral or suprapubic catheter will be used. There are a choice of drainage systems for use with indwelling urinary catheters including bed bags, link systems and catheter valves. Catheter valves are not suitable for everybody and patient assessment is vital: only patients with the cognitive ability and manual dexterity to operate a valve should be offered this option for bladder drainage. Catheter valves offer a number of advantages over drainage bags including improved privacy and dignity, prevention of bladder-neck trauma, reduced catheter encrustation and maintenance of normal detrusor muscle function. A number of catheter valves are available, including the EZ-Flow valve, and patient choice is important when selecting an appropriate product.

  14. Survival rate of colorectal cancer patients during 2005-2010 in Zhejiang province,China

    Institute of Scientific and Technical Information of China (English)

    罗胜兰

    2014-01-01

    Objective To analyze the survival rate of colorectal cancer,using data from the population-based cancer registry during 2005—2010 in Zhejiang.Methods The last follow-up activites on 17 235 cases regarding the survival status was December 31,2012.Both cumulative observed survival rate(OS)and relative survival rate(RS)were calculated with

  15. Temperature-controlled irrigated tip radiofrequency catheter ablation: comparison of in vivo and in vitro lesion dimensions for standard catheter and irrigated tip catheter with minimal infusion rate

    DEFF Research Database (Denmark)

    Petersen, H H; Chen, X; Pietersen, A;

    1998-01-01

    In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures <60% partly due to the limited lesion size after conventional radiofrequency ablation. Irrigated tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has...... increased risk of cratering. The present study explores irrigated tip catheter ablation in temperature-controlled mode, target temperature 60 degrees C, using an irrigation rate of 1 mL/min, comparing this to conventional catheter technique, target temperature 80 degrees C.......In patients with ventricular tachycardias due to structural heart disease, catheter ablation cures tip radiofrequency ablation using power control and high infusion rates enlarges lesion size, but has...

  16. Conversion from temporary to tunneled catheters by nephrologists: report of a single-center experience

    Directory of Open Access Journals (Sweden)

    Silva BC

    2016-04-01

    Full Text Available Bruno C Silva, Camila E Rodrigues, Regina CRM Abdulkader, Rosilene M Elias Nephrology Division, Hospital das Clínicas, University of São Paulo, São Paulo, Brazil Background: Nephrologists have increasingly participated in the conversion from temporary catheters (TC to tunneled-cuffed catheters (TCCs for hemodialysis. Objective: To prospectively analyze the outcomes associated with TCC placement by nephrologists with expertise in such procedure, in different time periods at the same center. The impact of vancomycin or cefazolin as prophylactic antibiotics on the infection outcomes was also tested. Patients and methods: Hemodialysis patients who presented to such procedure were divided into two cohorts: A (from 2004 to 2008 and B (from 2013 to 2015. Time from TC to TCC conversion, prophylactic antibiotics, and reasons for TCC removal were evaluated. Results: One hundred and thirty patients were included in cohort A and 228 in cohort B. Sex, age, and follow-up time were similar between cohorts. Median time from TC to TCC conversion was longer in cohort A than in cohort B (14 [3; 30] vs 4 [1; 8] days, respectively; P<0.0001. Infection leading to catheter removal occurred in 26.4% vs 18.9% of procedures in cohorts A and B, respectively, and infection rate was 0.93 vs 0.73 infections per 1,000 catheter-days, respectively (P=0.092. Infection within 30 days from the procedure occurred in 1.4% of overall cohort. No differences were observed when comparing vancomycin and cefazolin as prophylactic antibiotics on 90-day infection-free TCC survival in a Kaplan–Meier model (log-rank = 0.188. TCC removal for low blood flow occurred in 8.9% of procedures. Conclusion: Conversion of TC to TCC by nephrologists had overall infection, catheter patency, and complications similar to data reported in the literature. Vancomycin was not superior to cefazolin as a prophylactic antibiotic. Keywords: renal dialysis, tunneled catheters, interventional nephrology

  17. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution.

    OpenAIRE

    Betjes, Michiel; Agteren, Madelon

    2004-01-01

    textabstractBACKGROUND: The use of haemodialysis catheters is complicated by catheter-related sepsis. Intraluminal colonization of the catheter with bacteria is important in the pathogenesis of catheter-related sepsis. The use of a catheter lock solution containing the antimicrobial taurolidine might prevent bacterial colonization, thereby reducing the incidence of catheter-related sepsis. METHODS: In a randomized prospective trial, patients receiving a dialysis catheter were included and cat...

  18. Exploring relationships of catheter-associated urinary tract infection and blockage in people with long-term indwelling urinary catheters.

    Science.gov (United States)

    Wilde, Mary H; McMahon, James M; Crean, Hugh F; Brasch, Judith

    2017-09-01

    To describe and explore relationships among catheter problems in long-term indwelling urinary catheter users, including excess healthcare use for treating catheter problems. Long-term urinary catheter users experience repeated problems with catheter-related urinary tract infection and blockage of the device, yet little has been reported of the patterns and relationships among relevant catheter variables. Secondary data analysis was conducted from a sample in a randomised clinical trial, using data from the entire sample of 202 persons over 12 months' participation. Descriptive statistics were used to characterise the sample over time. Zero-inflated negative binomial models were employed for logistic regressions to evaluate predictor variables of the presence/absence and frequencies of catheter-related urinary tract infection and blockage. Catheter-related urinary tract infection was marginally associated with catheter blockage. Problems reported at least once per person in the 12 months were as follows: catheter-related urinary tract infection 57%, blockage 34%, accidental dislodgment 28%, sediment 87%, leakage (bypassing) 67%, bladder spasms 59%, kinks/twists 42% and catheter pain 49%. Regression analysis demonstrated that bladder spasms were significantly related to catheter-related urinary tract infection and sediment amount, and catheter leakages were marginally significantly and positively related to catheter-related urinary tract infection. Frequencies of higher levels of sediment and catheter leakage were significantly associated with higher levels of blockage, and being female was associated with fewer blockages. Persons who need help with eating (more disabled) were also more likely to have blockages. Catheter-related urinary tract infection and blockage appear to be related and both are associated with additional healthcare expenditures. More research is needed to better understand how to prevent adverse catheter outcomes and patterns of problems in

  19. Ion cumulation by conical cathode electrolysis.

    CERN Document Server

    Grishin, V G

    2002-01-01

    Results of solid-state sodium stearate electrolysis with conical and cylindrical cathodes is presented here. Both electric measurement and conical samples destruction can be explained if a stress developing inside the conical sample is much bigger than in the cylindrical case and there is its unlimited amplification along cone slopes. OTHER KEYWORDS: ion, current, solid, symmetry, cumulation, polarization, depolarization, ionic conductor,superionic conductor, ice, crystal, strain, V-center, V-centre, doped crystal, interstitial impurity, intrinsic color center, high pressure technology, Bridgman, anvil, experiment, crowdion, dielectric, proton, layer, defect, lattice, dynamics, electromigration, mobility, muon catalysis, concentration, doping, dopant, conductivity, pycnonuclear reaction, permittivity, dielectric constant, point defects, interstitials, polarizability, imperfection, defect centers, glass, epitaxy, sodium hydroxide, metallic substrate, crystallization, point, tip, susceptibility, ferroelectric, ...

  20. [Cumulative trauma disorders: work or professional disease?].

    Science.gov (United States)

    de Carvalho, Marcus Vitor Diniz; Cavalcanti, Francisco Ivo Dantas; Soriano, Evelyne Pessoa; de Miranda, Hênio Ferreira

    2009-06-01

    This study aimed at reviewing the Brazilian legislation applied to occupational health. It refers to the diseases embodied in the Repetition Strain Injury (RSI) and Cumulative Trauma Disorders (CTD) regarded as work or professional diseases. This analysis allowed to perform the historical evolution of legislation concerning the issue, noting that the state of the art of regulation on RSI-CTD is anchored in specific regulation present in the Normative Instruction 98/2003, that establishes the diagnostic criteria and classification of RSI-CTD. It was concluded that according to the existing legislation in Brazil, the pathologies related to RSI-CTD are considered as work diseases and their legal effects are similar to the work-related accidents.

  1. Modelling survival

    DEFF Research Database (Denmark)

    Ashauer, Roman; Albert, Carlo; Augustine, Starrlight

    2016-01-01

    The General Unified Threshold model for Survival (GUTS) integrates previously published toxicokinetic-toxicodynamic models and estimates survival with explicitly defined assumptions. Importantly, GUTS accounts for time-variable exposure to the stressor. We performed three studies to test...... the ability of GUTS to predict survival of aquatic organisms across different pesticide exposure patterns, time scales and species. Firstly, using synthetic data, we identified experimental data requirements which allow for the estimation of all parameters of the GUTS proper model. Secondly, we assessed how...

  2. The bacterial colonization in tunneled cuffed dialysis catheter and its effects on residual renal function in incident hemodialysis patients.

    Science.gov (United States)

    Kang, Jin Suk; Jang, Hee Ryeong; Lee, Jeong Eun; Park, Young Joo; Rhee, Harin; Seong, Eun Young; Kwak, Ihm Soo; Kim, Il Young; Lee, Dong Won; Lee, Soo Bong; Song, Sang Heon

    2016-04-01

    The bacterial colonization of hemodialysis catheter occurs frequently and reaches to the catheter-related bloodstream infections (CRBSIs). We hypothesized bacterial colonization promotes inflammation and that might be associated with renal outcome. The aim of this study was to investigate the colonization status for tunneled cuffed dialysis catheter (TCC) and the factors for contributing to the catheter colonization and explore whether bacterial colonization would be related with declining of residual renal function (RRF). 115 patients who received TCC removal operation and underwent catheter tip culture from January 2005 to June 2014 were enrolled. The follow-up data such as urine output (UO), time to anuria and patients' survival were collected from the patients or their family members by telephone in June, 2014. There were nineteen patients (16.5 %, 19/115) with positive tip culture (colonization group). In the analysis of demographic and biochemical parameters, there were no significant differences between both groups. Fifty of all the subjects responded to the telephone survey and ten patients (20.0 %, 10/50) belonged to colonization group. The monthly decreasing rate of UO was significantly more rapid in colonization group (p = 0.001). The survival analysis showed that colonization group had worse estimated anuria-free survival than non-colonization group (p < 0.001). In multivariate cox regression, bacterial colonization of TCC was an independent factor influencing the loss of RRF (HR 4.29, 95 % CI: 1.905-9.683, p ≤ 0.001). Bacterial colonization of TCC was associated with rapid loss of RRF.

  3. Unplanned Start on Peritoneal Dialysis Right after PD Catheter Implantation for Older People with End-Stage Renal Disease.

    Science.gov (United States)

    Povlsen, Johan V; Sørensen, Anette Bagger; Ivarsen, Per

    2015-11-01

    Unplanned start on dialysis remains a major problem for the dialysis community worldwide. Late-referred patients with end-stage renal disease (ESRD) and urgent need for dialysis are overrepresented among older people. These patients are particularly likely to be started on in-center hemodialysis (HD), with a temporary vascular access known to be associated with excess mortality and increased risks of potentially lethal complications such as bacteremia and central venous thrombosis or stenosis.The present paper describes in detail our program for unplanned start on automated peritoneal dialysis (APD) right after PD catheter implantation and summarizes our experiences with the program so far. Compared with planned start on PD after at least 2 weeks of break-in between PD catheter implantation and initiation of dialysis, unplanned start may be associated with a slight increased risk of mechanical complications but apparently no detrimental effect on mortality, peritonitis-free survival, or PD technique survival.In our opinion and experience, the risk of serious complications associated with the implantation and immediate use of a PD catheter is less than the risk of complications associated with unplanned start on HD with a temporary central venous catheter (CVC). Unplanned start on APD is a gentle, safe, and feasible alternative to unplanned start on HD with a temporary CVC that is also valid for the late-referred older patient with ESRD and urgent need for dialysis. Copyright © 2015 International Society for Peritoneal Dialysis.

  4. Difficult embryo transfers or blood on catheter and assisted reproductive outcomes: a systematic review and meta-analysis.

    Science.gov (United States)

    Phillips, James A S; Martins, Wellington P; Nastri, Carolina O; Raine-Fenning, Nicholas J

    2013-06-01

    We performed a systematic review and meta-analysis to examine whether a difficult embryo transfer or the presence of blood on the transfer catheter affects assisted reproduction outcomes. We searched the following databases: Cochrane Central Register of Controlled Trials (CENTRAL), Database of Abstracts of Reviews of Effects (DARE), MEDLINE, Embase, PsycINFO, Cumulative Index to Nursing and Allied Health Literature (CINAHL), and Literatura Latino-Americana e do Caribe em Ciências da Saúde (LILACS). We aimed to determine the risk ratio (RR) associated with difficult embryo transfer or the presence of blood on the transfer catheter for the following outcomes: live birth, clinical pregnancy, and miscarriage. We identified 3066 papers, of which 194 were reviewed and nine were included. The outcome of live birth was not reported in any of the included studies and the effect on miscarriage was too imprecise for any conclusions. Pooled analysis of five studies demonstrated lower clinical pregnancy rates following a non-easy embryo transfer (RR=0.75; 95% CI=0.66-0.86). This included three studies showing subjectively difficult transfers reducing clinical pregnancies (RR=0.67; 95% CI=0.51-0.87) and two studies in which the need for additional manoeuvers reduced clinical pregnancies (RR=0.78; 95% CI=0.67-0.91). The presence of blood on the transfer catheter did not affect clinical pregnancy rates (RR=0.96; 95% CI=0.82-1.14) in five studies. We concluded that low quality evidence suggests that a difficult embryo transfer but not a bloody catheter reduces the chance of achieving a clinical pregnancy. More good quality studies are needed to evaluate the effect of difficult embryo transfer and the presence of blood on the catheter on the main outcomes of assisted reproduction.

  5. Pancreas tumor interstitial pressure catheter measurement

    Science.gov (United States)

    Nieskoski, Michael D.; Gunn, Jason; Marra, Kayla; Trembly, B. Stuart; Pogue, Brian W.

    2016-03-01

    This paper highlights the methodology in measuring interstitial pressure in pancreatic adenocarcinoma tumors. A Millar Mikrotip pressure catheter (SPR-671) was used in this study and a system was built to amplify and filter the output signal for data collection. The Millar pressure catheter was calibrated prior to each experiment in a water column at 37°C, range of 0 to 60 inH2O (112 mmHg), resulting in a calibration factor of 33 mV / 1 inH2O. The interstitial pressures measured in two orthotopically grown pancreatic adenocarcinoma tumor were 57 mmHg and 48 mmHg, respectively. Verteporfin uptake into the pancreatic adenocarcinoma tumor was measured using a probe-based experimental dosimeter.

  6. Urgent peritoneal dialysis or hemodialysis catheter dialysis.

    Science.gov (United States)

    Lok, Charmaine E

    2016-03-01

    Worldwide, there is a steady incident rate of patients with end-stage kidney disease (ESKD) who require renal replacement therapy. Of these patients, approximately one-third have an "unplanned" or "urgent" start to dialysis. This can be a very challenging situation where patients have either not had adequate time for education and decision making regarding dialysis modality and appropriate dialysis access, or a decision was made and plans were altered due to unforeseen circumstances. Despite such unplanned starts, clinicians must still consider the patient's ESKD "life-plan", which includes the best initial dialysis modality and access to suit the patient's individual goals and their medical, social, logistic, and facility circumstances. This paper will discuss the considerations of peritoneal dialysis and a peritoneal dialysis catheter access and hemodialysis and central venous catheter access in patients who require an urgent start to dialysis.

  7. Recommended Clinical Trial End Points for Dialysis Catheters.

    Science.gov (United States)

    Allon, Michael; Brouwer-Maier, Deborah J; Abreo, Kenneth; Baskin, Kevin M; Bregel, Kay; Chand, Deepa H; Easom, Andrea M; Mermel, Leonard; Mokrzycki, Michele H; Patel, Priti R; Roy-Chaudhury, Prabir; Shenoy, Surendra; Valentini, Rudolph P; Wasse, Haimanot

    2017-07-20

    Central venous catheters are used frequently in patients on hemodialysis as a bridge to a permanent vascular access. They are prone to frequent complications, including catheter-related bloodstream infection, catheter dysfunction, and central vein obstruction. There is a compelling need to develop new drugs or devices to prevent central venous catheter complications. We convened a multidisciplinary panel of experts to propose standardized definitions of catheter end points to guide the design of future clinical trials seeking approval from the Food and Drug Administration. Our workgroup suggests diagnosing catheter-related bloodstream infection in catheter-dependent patients on hemodialysis with a clinical suspicion of infection (fever, rigors, altered mental status, or unexplained hypotension), blood cultures growing the same organism from the catheter hub and a peripheral vein (or the dialysis bloodline), and absence of evidence for an alternative source of infection. Catheter dysfunction is defined as the inability of a central venous catheter to (1) complete a single dialysis session without triggering recurrent pressure alarms or (2) reproducibly deliver a mean dialysis blood flow of >300 ml/min (with arterial and venous pressures being within the hemodialysis unit parameters) on two consecutive dialysis sessions or provide a Kt/V≥1.2 in 4 hours or less. Catheter dysfunction is defined only if it persists, despite attempts to reposition the patient, reverse the arterial and venous lines, or forcefully flush the catheter. Central vein obstruction is suspected in patients with >70% stenosis of a central vein by contrast venography or the equivalent, ipsilateral upper extremity edema, and an existing or prior history of a central venous catheter. There is some uncertainty about the specific criteria for these diagnoses, and the workgroup has also proposed future high-priority studies to resolve these questions. Copyright © 2017 by the American Society of

  8. Baclofen pump catheter leakage after migration of the abdominal catheter in a pediatric patient with spasticity.

    Science.gov (United States)

    Dastgir, Amer; Ranalli, Nathan J; MacGregor, Theresa L; Aldana, Philipp R

    2015-09-01

    The authors report an unusual case of intrathecal baclofen withdrawal due to the perforation and subsequent leakage of a baclofen pump catheter in a patient with spastic cerebral palsy. A 15-year-old boy underwent an uncomplicated placement of an intrathecal baclofen pump for the treatment of spasticity due to cerebral palsy. After excellent control of symptoms for 3 years, the patient presented to the emergency department with increasing tremors following a refill of his baclofen pump. Initial evaluation consisted of radiographs of the pump and catheter, which appeared normal, and a successful aspiration of CSF from the pump's side port. A CT dye study revealed a portion of the catheter directly overlying the refill port and extravasation of radiopaque dye into the subfascial pocket anterior to the pump. During subsequent revision surgery, a small puncture hole in the catheter was seen to be leaking the drug. The likely cause of the puncture was an inadvertent perforation of the catheter by a needle during the refilling of the pump. This case report highlights a unique complication in a patient with an intrathecal baclofen pump. Physicians caring for these patients should be aware of this rare yet potential complication in patients presenting with baclofen withdrawal symptoms.

  9. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Science.gov (United States)

    Urbanetto, Janete de Souza; Peixoto, Cibelle Grassmann; May, Tássia Amanda

    2016-01-01

    ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC) and following their removal - (post-infusion phlebitis) in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective. PMID:27508916

  10. Soft robotic concepts in catheter design: an on-demand fouling-release urinary catheter.

    Science.gov (United States)

    Levering, Vrad; Wang, Qiming; Shivapooja, Phanindhar; Zhao, Xuanhe; López, Gabriel P

    2014-10-01

    Infectious biofilms are problematic in many healthcare-related devices and are especially challenging and ubiquitous in urinary catheters. This report presents an on-demand fouling-release methodology to mechanically disrupt and remove biofilms, and proposes this method for the active removal of infectious biofilms from the previously inaccessible main drainage lumen of urinary catheters. Mature Proteus mirabilis crystalline biofilms detach from silicone elastomer substrates upon application of strain to the substrate, and increasing the strain rate increases biofilm detachment. The study presents a quantitative relationship between applied strain rate and biofilm debonding through an analysis of biofilm segment length and the driving force for debonding. Based on this mechanism, hydraulic and pneumatic elastomer actuation is used to achieve surface strain selectively within the lumen of prototypes of sections of a fouling-release urinary catheter. Proof-of-concept prototypes of sections of active, fouling-release catheters are constructed using techniques typical to soft robotics including 3D printing and replica molding, and those prototypes demonstrate release of mature P. mirabilis crystalline biofilms (e.g., ≈90%) from strained surfaces. These results provide a basis for the development of a new urinary catheter technology in which infectious biofilms are effectively managed through new methods that are entirely complementary to existing approaches.

  11. Incidence of phlebitis associated with the use of peripheral IV catheter and following catheter removal

    Directory of Open Access Journals (Sweden)

    Janete de Souza Urbanetto

    Full Text Available ABSTRACT Objective: to investigate the incidence of phlebitis and its association with risk factors when using peripheral IV catheters (PIC and following their removal - (post-infusion phlebitis in hospitalized adults. Method: a cohort study of 171 patients using PIC, totaling 361 punctures. Sociodemographic variables and variables associated with the catheter were collected. Descriptive and analytical statistical analyses were performed. Results: average patient age was 56.96 and 51.5% of the sample population was male. The incidence of phlebitis was 1.25% while using PIC, and 1.38% post-infusion. The incidence of phlebitis while using PIC was associated with the length of time the catheter remained in place, whereas post-infusion phlebitis was associated with puncture in the forearm. Ceftriaxone, Clarithromycin and Oxacillin are associated with post-infusion phlebitis. Conclusions: this study made it possible to investigate the association between risk factors and phlebitis during catheter use and following its removal. The frequency of post-infusion phlebitis was larger than the incidence of phlebitis with the catheter in place, with Phlebitis Grade III and II being the most frequently found in each of these situations, respectively. Aspects related to post-infusion phlebitis can be explained, given the limited number of studies addressing this theme from this perspective.

  12. Transpleural central venous catheter discovered during thoracotomy

    Directory of Open Access Journals (Sweden)

    Ashima Malhotra

    2014-01-01

    Full Text Available We report an uncommon complication of subclavian central venous catheterization, discovered at thoracotomy. The central venous catheter (CVC was placed by left infraclavicular route after induction of general anesthesia. CVC was secured after aspiration of blood and satisfactory central venous tracing. On thoracotomy, CVC was noticed to traverse the pleural cavity while the tracing was normal. CVC was thus removed consequent to which bleeding from each puncture site was noticed, that were secured surgically.

  13. Biocide Activity against Urinary Catheter Pathogens

    OpenAIRE

    Malic, Sladjana; Rachael P. C. Jordan; Waters, Mark G. J.; Stickler, David J.; Williams, David W

    2014-01-01

    Antimicrobial effects of essential oils against bacteria associated with urinary catheter infection was assessed. Tests were performed on 14 different bacterial species cultured either planktonically or as biofilms. Biofilms were found to be up to 8-fold more tolerant of the test agents. Higher antimicrobial tolerance was also evident in tests conducted in artificial urine. Eugenol exhibited higher antimicrobial effects against both planktonic cells and biofilms than did terpinen, tea tree oi...

  14. Flow Structure Associated with Hemodialysis Catheters

    Science.gov (United States)

    Foust, Jason

    2005-11-01

    Insertion of a hemodialysis catheter into the superior vena cava (SVC) gives rise to complex flow patterns, which arise from the simultaneous injection and extraction of blood through different holes (ports) of the catheter. Techniques of high-image-density particle image velocimetry are employed in a scaled-up water facility. This approach allows characterization of both the instantaneous and time-averaged flow structure due to generic classes of side hole geometries. The trajectory of the injection jet is related to the ratio of the initial jet velocity to the mainstream velocity through the SVC, and to the type of distortion of the jet cross-section. Furthermore, the mean and fluctuating velocity and vorticity fields are determined. Significant turbulent stresses develop rapidly in the injection jet, which can impinge upon the wall of the simulated SVC. Immediately downstream of the injection hole, a recirculation cell of low velocity exists adjacent to the catheter surface. These and other representations of the flow structure are first evaluated for a steady throughflow, then for the case of a pulsatile waveform in the SVC, which matches that of a normal adult.

  15. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution.

    NARCIS (Netherlands)

    M.G.H. Betjes (Michiel); M. Agteren (Madelon)

    2004-01-01

    textabstractBACKGROUND: The use of haemodialysis catheters is complicated by catheter-related sepsis. Intraluminal colonization of the catheter with bacteria is important in the pathogenesis of catheter-related sepsis. The use of a catheter lock solution containing the antimicrobia

  16. Prevention of dialysis catheter-related sepsis with a citrate-taurolidine-containing lock solution.

    NARCIS (Netherlands)

    M.G.H. Betjes (Michiel); M. Agteren (Madelon)

    2004-01-01

    textabstractBACKGROUND: The use of haemodialysis catheters is complicated by catheter-related sepsis. Intraluminal colonization of the catheter with bacteria is important in the pathogenesis of catheter-related sepsis. The use of a catheter lock solution containing the antimicrobia

  17. [Biodegradable catheters and urinary stents. When?

    Science.gov (United States)

    Soria, F; Morcillo, E; López de Alda, A; Pastor, T; Sánchez-Margallo, F M

    2016-10-01

    One of the main wishes in the field of urinary catheters and stents is to arm them with biodegradable characteristics because we consider a failure of these devices the need for retrieval, the forgotten catheter syndrome as well as the adverse effects permanent devices cause after fulfilling their aim. The efforts focused in new designs, coatings and biomaterials aim to increase the biocompatibility of theses internal devices. Lately, there have been correct advances to answer the main challenges regarding biodegradable ureteral devices. Thus, modulation of the rate of degradation has been achieved thanks to new biomaterials and the use of copolymers that enable to choose the time of permanence as it is programmed with conventional double J catheters. Biocompatibility has improved with the use of new polymers that adapt better to the urine. Finally, one of the main problems is elimination of degraded fragments and experimentally it has be demonstrated that new designs elicit controlled degradation, from distal to proximal; using stranding and combination of copolymers degradation may be caused by dilution, reducing fragmentation to the last stages of life of the prosthesis. Moreover, it has been demonstrated that biodegradable catheters potentially may cause less urinary tract infection, less encrustation and predictably they will diminish catheter morbidity, since their degradation process reduces adverse effects. Regarding the development of biodegradable urethral stents, it is necessary to find biomaterials that enable maintaining their biomechanical properties in the long term, keeping open the urethral lumen both in patients with BPH and urethral stenosis. Modulation of the time of degradation of the prosthesis has been achieved, but the appearance of urothelial hyperplasia is still a constant in the initial phases after implantation. The development of drug eluting stents, anti-proliferative or anti-inflammatory, as well as biodegradable stents biocoated is a

  18. Pseudo-observations in survival analysis

    DEFF Research Database (Denmark)

    Andersen, Per Kragh; Perme, Maja Pohar

    2010-01-01

    We review recent work on the application of pseudo-observations in survival and event history analysis. This includes regression models for parameters like the survival function in a single point, the restricted mean survival time and transition or state occupation probabilities in multi......-state models, e.g. the competing risks cumulative incidence function. Graphical and numerical methods for assessing goodness-of-fit for hazard regression models and for the Fine-Gray model in competing risks studies based on pseudo-observations are also reviewed. Sensitivity to covariate-dependent censoring...... is studied. The methods are illustrated using a data set from bone marrow transplantation....

  19. Empirical likelihood method in survival analysis

    CERN Document Server

    Zhou, Mai

    2015-01-01

    Add the Empirical Likelihood to Your Nonparametric ToolboxEmpirical Likelihood Method in Survival Analysis explains how to use the empirical likelihood method for right censored survival data. The author uses R for calculating empirical likelihood and includes many worked out examples with the associated R code. The datasets and code are available for download on his website and CRAN.The book focuses on all the standard survival analysis topics treated with empirical likelihood, including hazard functions, cumulative distribution functions, analysis of the Cox model, and computation of empiric

  20. Pseudo-observations in survival analysis.

    Science.gov (United States)

    Andersen, Per Kragh; Perme, Maja Pohar

    2010-02-01

    We review recent work on the application of pseudo-observations in survival and event history analysis. This includes regression models for parameters like the survival function in a single point, the restricted mean survival time and transition or state occupation probabilities in multi-state models, e.g. the competing risks cumulative incidence function. Graphical and numerical methods for assessing goodness-of-fit for hazard regression models and for the Fine-Gray model in competing risks studies based on pseudo-observations are also reviewed. Sensitivity to covariate-dependent censoring is studied. The methods are illustrated using a data set from bone marrow transplantation.

  1. A prototype catheter designed for ultraviolet C disinfection

    DEFF Research Database (Denmark)

    Bak, Jimmy; Begovic, Tanja

    2013-01-01

    Background Disinfection of the intraluminal space of single-lumen polymer tubes can be obtained by ultraviolet C (UVC) light exposure from an external light source. In existing catheters UVC disinfection is hampered by the design of the catheter hub and tube connector. Aim To demonstrate...... that it is possible to design a single-lumen catheter with a hub, tube connector and tube parts that can be UVC-disinfected throughout its entire lumen. Methods Two single-lumen catheters were designed: one control and one for UVC exposure. They were contaminated with Pseudomonas aeruginosa (104–105 cfu/mL) before...... UVC light exposure, sampling and plate counting. Findings Two minutes of UVC exposure was sufficient to obtain 4 log10 disinfection for the full-length prototype catheter. This exposure corresponds to ∼40 mJ/cm2 at the catheter tip and indicates that even shorter exposure times can be achieved...

  2. Risk of infection after placement of an extraventricular drainage catheter

    Directory of Open Access Journals (Sweden)

    Novak Vesna

    2012-01-01

    Full Text Available Introduction. The occurrence of infection after the placement of an extraventricular drainage (EVD catheter can be a very serious problem in neurosurgery. Objective. The aim of this study was to confirm that the use of special catheters with impregnated antibiotics decreased the percentage of infection. Methods. The prospective study conducted at the Clinic of Neurosurgery in Niš in the period 2006-2009 is presented. Group 1 comprised of 43 patients in whom a commonly used system for EVD was applied. Group 2 comprised of 39 patients in whom the Rifampycin and Clindamycin impregnated EVD catheters were applied (Bactiseal catheters. Results. In Group 1 infection occurred in nine patients, mainly caused by bacteria of Staphylococcus genus. In Group 2 only two patients developed infections caused by Acinetobacter. Conclusion. The use of Bactiseal EVD catheters considerably decreased the percentage of infection occurrence with prolonged EVD catheter drainage period.

  3. Conceptual Design and Procedure for an Autonomous Intramyocardial Injection Catheter.

    Science.gov (United States)

    Cheng, Weyland; Law, Peter

    2016-12-07

    This article discusses existing catheter systems and proposes a conceptual design and procedure for an autonomous cellinjection catheter for the purpose of transferring committed myogenic or undifferentiated stem cells into the infarct boundary zones of the left ventricle. Operation of existing catheters used for cell delivery is far from optimal. Commercial injection catheters available are hand-held devices operated manually by means of tip deflection and torque capabilities. Interventionists require a hefty learning curve and often encounter difficulties in catheter stabilization and infarct detection, resulting in lengthy operation times and non-precise injections. We examined current technologies and proposed a design incorporating robotic positional control, feedback signals, and an adaptable operational sequence to overcome these problems. The design provides the basis for the construction of a robotic catheter that is able to autonomously assist the physician in transferring myogenic cells to the left ventricle infarct boundary zones.

  4. Central venous catheter placement: where is the tip?

    Science.gov (United States)

    Ibrahim, George M

    2012-09-01

    The insertion of central venous catheters is a common bedside procedure performed in intensive care units. Here, we present a case of an 82-year-old man who underwent insertion of a central venous catheter in the internal jugular vein without perceived complications. Postprocedural radiographs showed rostral migration of the catheter, and computed tomography performed coincidentally showed cannulation of the jugular bulb at the level of the jugular foramen. To our knowledge, this is the first report to document migration of a central venous catheter from the internal jugular vein into the dural sinuses, as confirmed by computed tomography. The case highlights the importance of acquiring postprocedural radiographs for all insertions of central venous catheters to confirm catheter placement.

  5. Penile strangulation and necrosis due to condom catheter.

    Science.gov (United States)

    Özkan, Heval S; İrkoren, Saime; Sivrioğlu, Nazan

    2015-06-01

    Condom catheters are often used in the management of male urinary incontinence, and are considered to be safe. As condom catheters are placed on the male genitalia, sometimes adequate care is not taken after placement owing to poor medical care of debilitated patients and feelings of embarrassment and shame. Similarly, sometimes the correct size of penile sheath is not used. Strangulation of penis due to condom catheter is a rare condition; only few such cases have been reported in the literature. Proper application and routine care of condom catheters are important in preventing this devastating complication especially in a neurologically debilitated population. We present a case of penile necrosis due to condom catheter. We will also discuss proper catheter care and treatment of possible complications.

  6. [Infection associated with hemodialysis and peritoneal dialysis catheters].

    Science.gov (United States)

    Fariñas, María Carmen; García-Palomo, José Daniel; Gutiérrez-Cuadra, Manuel

    2008-10-01

    Catheter-related infections in hemodialysis (HD) and peritoneal dialysis (PD) are one of the most common causes of morbidity and mortality in patients with end-stage renal disease. Staphylococcus aureus in HD patients and S. aureus and Pseudomonas aeruginosa in PD patients are the most common causative organisms isolated. Currently, the diagnostic tests with highest yield in suspected catheter-related infection in HD patients have not been established, and tests used for central venous catheters (CVC) in general are applied. Management of the infected HD catheter and the use of antimicrobial therapy are similar to the measures used for other CVCs, with some specific recommendations. Peritonitis is the most severe complication in PD patients. Improving hygiene conditions in catheter insertion, treatment of S. aureus nasal carriers, regular treatment of the catheter's exit site, and antibiotic lock therapy have been associated with a reduction of infectious episodes in HD and PD patients.

  7. Technique of Peritoneal Catheter Placement under Fluroscopic Guidance

    Directory of Open Access Journals (Sweden)

    Ahmed Kamel Abdel-Aal

    2011-01-01

    Full Text Available Peritoneal catheters are mainly used for peritoneal dialysis in patients with end-stage renal disease. Other uses of this catheter include intraperitoneal chemotherapy and gene therapy for ovarian cancer and draining of uncontrolled refractory ascites in patients with liver cirrhosis. Traditionally, surgeons place most of these peritoneal catheters either by laparoscopy or open laparotomy. We detail our percutaneous approach to placing peritoneal catheters using fluoroscopic guidance. We emphasize the use of additional ultrasound guidance, including gray scale and color Doppler ultrasound, to determine the safest puncture site and to guide the initial needle puncture in order to avoid bowel perforation and injury to epigastric artery. We present our experience in placing peritoneal catheters using this technique in 95 patients with various indications. Fluoroscopic guided percutaneous placement of peritoneal catheters is a safe, minimally invasive, and effective alternative to open surgical or laparoscopic placement.

  8. Catheter sepsis due to Staphylococcus epidermidis during parenteral nutrition.

    Science.gov (United States)

    Sitges-Serra, A; Puig, P; Jaurrieta, E; Garau, J; Alastrue, A; Sitges-Creus, A

    1980-10-01

    Staphylococcus epidermidis is a pathogenic organism with increasing importance in total parenteral nutrition therapy. Strict asepsis during catheter insertion prolongs the interval free from Staphylococcus epidermidis infection. Staphylococcus epidermidis colonizes the catheter after migrating from the skin. For protection, we advise a long subcutaneous tunnel for all catheters that are to be indwelling for longer than three weeks. Prompt recatheterization of a patient with Staphylococcus epidermidis sepsis can result in hematogenous seeding of the new catheter and persistence of the infection. Catheter related Staphylococcus epidermidis sepsis has subsided after catheter withdrawal, and there is no need for antibiotic therapy provided that other prosthetic materials are not placed in the vascular tree. Immunologic status of the patients is not related to the frequency or severity of Staphylococcus epidermidis infections, or both.

  9. Long and Short Term Cumulative Structural Priming Effects.

    Science.gov (United States)

    Kaschak, Michael P; Kutta, Timothy J; Coyle, Jacqueline M

    We present six experiments that examine cumulative structural priming effects (i.e., structural priming effects that accumulate across many utterances). Of particular interest is whether (1) cumulative priming effects transfer across language production tasks and (2) the transfer of cumulative priming effects across tasks persists over the course of a week. Our data suggest that cumulative structural priming effects do transfer across language production tasks (e.g., from written stem completion to picture description, and from picture description to written stem completion), but only when both tasks are presented in the same experimental session. When cumulative priming effects are established in one task, and the second (changed) task is not presented until a week later, the cumulative priming effects are not observed.

  10. Why Veterinary Medical Educators Should Embrace Cumulative Final Exams.

    Science.gov (United States)

    Royal, Kenneth D

    2017-01-03

    The topic of cumulative final examinations often elicits polarizing opinions from veterinary medical educators. While some faculty prefer cumulative finals, there are many who perceive these types of examinations as problematic. Specifically, faculty often cite cumulative examinations are more likely to cause students' greater stress, which may in turn result in negative student evaluations of teaching. Cumulative finals also restrict the number of items one may present to students on most recent material. While these cited disadvantages may have some merit, the advantages of cumulative examinations far exceed the disadvantages. The purpose of this article is to discuss the advantages of cumulative examinations with respect to learning evidence, grade/score validity, fairness issues, and implications for academic policy.

  11. Educational interventions for preventing vascular catheter bloodstream infections in critical care: evidence map, systematic review and economic evaluation.

    Science.gov (United States)

    Frampton, Geoff K; Harris, Petra; Cooper, Keith; Cooper, Tracey; Cleland, Jennifer; Jones, Jeremy; Shepherd, Jonathan; Clegg, Andrew; Graves, Nicholas; Welch, Karen; Cuthbertson, Brian H

    2014-02-01

    Bloodstream infections resulting from intravascular catheters (catheter-BSI) in critical care increase patients' length of stay, morbidity and mortality, and the management of these infections and their complications has been estimated to cost the NHS annually £19.1-36.2M. Catheter-BSI are thought to be largely preventable using educational interventions, but guidance as to which types of intervention might be most clinically effective is lacking. To assess the effectiveness and cost-effectiveness of educational interventions for preventing catheter-BSI in critical care units in England. Sixteen electronic bibliographic databases - including MEDLINE, MEDLINE In-Process & Other Non-Indexed Citations, Cumulative Index to Nursing and Allied Health Literature (CINAHL), NHS Economic Evaluation Database (NHS EED), EMBASE and The Cochrane Library databases - were searched from database inception to February 2011, with searches updated in March 2012. Bibliographies of systematic reviews and related papers were screened and experts contacted to identify any additional references. References were screened independently by two reviewers using a priori selection criteria. A descriptive map was created to summarise the characteristics of relevant studies. Further selection criteria developed in consultation with the project Advisory Group were used to prioritise a subset of studies relevant to NHS practice and policy for systematic review. A decision-analytic economic model was developed to investigate the cost-effectiveness of educational interventions for preventing catheter-BSI. Seventy-four studies were included in the descriptive map, of which 24 were prioritised for systematic review. Studies have predominantly been conducted in the USA, using single-cohort before-and-after study designs. Diverse types of educational intervention appear effective at reducing the incidence density of catheter-BSI (risk ratios statistically significantly educational intervention in

  12. Analysis of experimental data on correlations between cumulative particles

    Energy Technology Data Exchange (ETDEWEB)

    Vlasov, A.V.; Doroshkevich, E.A.; Leksin, G.A. [Institute of Theoretical and Experimental Physics, Moscow (Russian Federation)] [and others

    1995-04-01

    Experimental data on correlations between cumulative particles are analyzed. A space-time and energy-transfer pattern of hadron-nucleus interaction based on both correlation data and data on the inclusive spectra of cumulative particles is considered. A new variable that is convenient for describing the production of cumulative particles is proposed using the concept of symmetry between the one-particle and multiparticle distributions. 32 refs., 9 figs., 1 tab.

  13. Catheter-related thrombosis in children with intestinal failure and long-term parenteral nutrition: How to treat and to prevent?

    NARCIS (Netherlands)

    C.H. van Ommen; M.M. Tabbers

    2010-01-01

    Survival of children with chronic intestinal failure has increased as result of administration of home parenteral nutrition. Crucial for the successful management of home parenteral nutrition is the availability of an adequate central venous access. Venous access can be fraught by episodes of cathet

  14. Analysis of Memory Codes and Cumulative Rehearsal in Observational Learning

    Science.gov (United States)

    Bandura, Albert; And Others

    1974-01-01

    The present study examined the influence of memory codes varying in meaningfulness and retrievability and cumulative rehearsal on retention of observationally learned responses over increasing temporal intervals. (Editor)

  15. Continuously Cumulating Meta-Analysis and Replicability.

    Science.gov (United States)

    Braver, Sanford L; Thoemmes, Felix J; Rosenthal, Robert

    2014-05-01

    The current crisis in scientific psychology about whether our findings are irreproducible was presaged years ago by Tversky and Kahneman (1971), who noted that even sophisticated researchers believe in the fallacious Law of Small Numbers-erroneous intuitions about how imprecisely sample data reflect population phenomena. Combined with the low power of most current work, this often leads to the use of misleading criteria about whether an effect has replicated. Rosenthal (1990) suggested more appropriate criteria, here labeled the continuously cumulating meta-analytic (CCMA) approach. For example, a CCMA analysis on a replication attempt that does not reach significance might nonetheless provide more, not less, evidence that the effect is real. Alternatively, measures of heterogeneity might show that two studies that differ in whether they are significant might have only trivially different effect sizes. We present a nontechnical introduction to the CCMA framework (referencing relevant software), and then explain how it can be used to address aspects of replicability or more generally to assess quantitative evidence from numerous studies. We then present some examples and simulation results using the CCMA approach that show how the combination of evidence can yield improved results over the consideration of single studies.

  16. Dose requirements for UVC disinfection of catheter biofilms

    DEFF Research Database (Denmark)

    Bak, Jimmy; Ladefoged, Søren D.; Tvede, Michael

    2009-01-01

    Bacterial biofilms on permanent catheters are the major sources of infection. Exposure to ultraviolet-C (UVC) light has been proposed as a method for disinfecting the inner surface of catheters. Specification of a UVC-based device for in vivo disinfection is based on the knowledge of the required...... newly inserted catheters free of contamination. The combination of high doses required to kill mature biofilm and the limited effect of current UVC light sources result in a relative long treatment time (similar to 60 min). If a UVC-based method is to be of practical use for disinfection of catheters...

  17. Pharmacological therapy following catheter ablation of atrial fibrillation.

    Science.gov (United States)

    Rordorf, Roberto; Savastano, Simone; Gandolfi, Edoardo; Vicentini, Alessandro; Petracci, Barbara; Landolina, Maurizio

    2012-01-01

    Catheter ablation has been proven to be an effective treatment for patients with drug-resistant atrial fibrillation. Nevertheless its efficacy is limited to 60-80% of patients in different studies. Whether the use of pharmacological therapy after catheter ablation of atrial fibrillation might increase the procedural success rate is still a matter of debate. There is general agreement that antiarrhythmic drugs (AADs) are useful in the management of arrhythmias occurring in the very early period after catheter ablation (blanking period). On the contrary, limited data are available on the efficacy of AADs over a longer period. Some patients remain free of arrhythmia recurrences by the use of AADs that were ineffective before catheter ablation: whether this latter situation is to be considered a partial success of catheter ablation or a treatment failure, thus demanding a redo procedure, is still an open question. Some studies have also investigated the role of non-AADs [angiotensin-converting enzyme (ACE) inhibitors, angiotensin II receptor blockers, statins and corticosteroids] in preventing atrial fibrillation recurrences after catheter ablation, reporting conflicting results. Whereas there is a general consensus on the use of anticoagulation therapy in the first phase after catheter ablation, no definite data are available on the proper long-term management of anticoagulation therapy after catheter ablation. This review focuses on the still open issue of what is the optimal pharmacological treatment of patients after catheter ablation of atrial fibrillation.

  18. Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers.

    Science.gov (United States)

    Saxena, Anil K; Panhotra, Bodh R; Al-hafiz, Abdul Aziz; Sundaram, Dasappan S; Abu-Oyun, Bassam; Al Mulhim, Khalifa

    2012-07-01

    Staphylococcus aureus nasal carriers undergoing hemodialysis (HD) through tunneled cuffed catheters (TCCs) form a high-risk group for the development of catheter-related bloodstream infections (CRBSI) and ensuing morbidity. The efficacy of antibiotic-locks on the outcomes of TCCs among S. aureus nasal carriers has not been studied earlier. Persistent nasal carriage was defined by two or more positive cultures for methicillin-susceptible (MSSA) or methicillin-resistant (MRSA) S. aureus of five standardized nasal swabs taken from all the participants dialyzed at a large out-patient HD center affiliated to a tertiary care hospital. Of 218 participants, 82 S. aureus nasal carriers dialyzed through TCCs (n = 88) were identified through April 2005 to March 2006 and randomized to two groups. Group I comprised of 39 nasal carriers who had TCCs (n = 41) "locked" with cefotaxime/heparin while group II included 43 patients with TCCs (n = 47) filled with standard heparin. The CRBSI incidence and TCC survival at 365 days were statistically compared between the two groups. A significantly lower CRBSI incidence (1.47 vs. 3.44/1000 catheter-days, P cefotaxime group compared with the standard heparin group. However, no significant difference in MRSA-associated CRBSI incidence was observed between the two groups. Cefotaxime-heparin "locks" effectively reduced CRBSI-incidence associated with gram-positive cocci, including MSSA, among S. aureus nasal carriers. There remains a compelling requirement for antibiotic-locks effective against MRSA.

  19. A retrospective study of palindrome symmetrical-tip catheters for chronic hemodialysis access in China.

    Science.gov (United States)

    Ye, Chaoyang; Mao, Zhiguo; Zhang, Pan; Zhang, Yuqiang; Rong, Shu; Chen, Jing; Mei, Changlin

    2015-07-01

    Hemodialysis catheters remain necessary for long-term vascular access in patients for whom arteriovenous access may be problematic or impossible. Developments in catheter design have improved long-term catheter functionality, and reduced the rate of infection and complications associated with their use. This retrospective study of 284 cases of chronic catheterization in 271 patients treated between 2009 and 2011 using Tal Palindrome™ symmetrical-tip (N = 118) or Quinton™ Permcath™ step-tip (N = 166) hemodialysis catheters evaluates the efficacy and the safety of symmetrical-tip dialysis catheters for chronic hemodialysis, compared with a step-tip catheter. Measurements of catheter performance included mean catheter dwell time, incidence of low blood flow, and rates of infection and catheter-related blood stream infection (CRBSI). The symmetrical-tip catheter had a significantly longer mean dwell time compared with the step-tip catheter; 329.4 ± 38.1 versus 273.1 ± 25.4 d (p catheter days was lower for the symmetrical-tip compared with the step-tip catheter; 1.13 versus 6.86 (p catheter was also associated with a lower incidence of complications; the rates of infection (0.28 vs. 0.78; p catheters, and catheter removal occurred less often for the symmetrical-tip catheter (8% vs. 16%; p hemodialysis catheter was associated with a longer mean dwell time, lower incidence of low blood flow, and lower infection rate compared with the step-tip catheter.

  20. Survival Analysis

    CERN Document Server

    Miller, Rupert G

    2011-01-01

    A concise summary of the statistical methods used in the analysis of survival data with censoring. Emphasizes recently developed nonparametric techniques. Outlines methods in detail and illustrates them with actual data. Discusses the theory behind each method. Includes numerous worked problems and numerical exercises.

  1. Improved method for the detection of catheter colonization and catheter-related bacteremia in newborns.

    Science.gov (United States)

    Martín-Rabadán, P; Pérez-García, F; Zamora Flores, E; Nisa, E S; Guembe, M; Bouza, E

    2017-04-01

    Accurate diagnosis of catheter-related bloodstream infection (CRBSI) is mandatory for hospital infection control. Peripherally inserted central venous catheters (PICCs) are widely used in intensive care units, but studies about procedures for detection of colonization are scarce in neonates. We sequentially processed 372 PICCs by 2 methods, first by the standard roll-plate (RP) technique and then by rubbing catheters on a blood agar plate after being longitudinally split (LS). With both techniques, we detected 133 colonized PICCs. Ninety-four events of CRBSI were diagnosed. The sensitivity, specificity, positive predictive value, and negative predictive value for detection of CRBSI were 58.5%, 92.8%, 73.3%, and 86.9%, respectively, for RP technique and 96.8%, 88.5%, 74.0%, and 98.8%, respectively, for LS technique. The LS technique increased the proportion of detected CRBSI by 38.3%. Neonatal PICC tips should be cultured after cutting them open. This technique is simple and sensitive to detect catheter colonization and also to diagnose CRBSI.

  2. Cumulative Effect of Depression on Dementia Risk

    Directory of Open Access Journals (Sweden)

    J. Olazarán

    2013-01-01

    Full Text Available Objective. To analyze a potential cumulative effect of life-time depression on dementia and Alzheimer’s disease (AD, with control of vascular factors (VFs. Methods. This study was a subanalysis of the Neurological Disorders in Central Spain (NEDICES study. Past and present depression, VFs, dementia status, and dementia due to AD were documented at study inception. Dementia status was also documented after three years. Four groups were created according to baseline data: never depression (nD, past depression (pD, present depression (prD, and present and past depression (prpD. Logistic regression was used. Results. Data of 1,807 subjects were investigated at baseline (mean age 74.3, 59.3% women, and 1,376 (81.6% subjects were evaluated after three years. The prevalence of dementia at baseline was 6.7%, and dementia incidence was 6.3%. An effect of depression was observed on dementia prevalence (OR [CI 95%] 1.84 [1.01–3.35] for prD and 2.73 [1.08–6.87] for prpD, and on dementia due to AD (OR 1.98 [0.98–3.99] for prD and OR 3.98 [1.48–10.71] for prpD (fully adjusted models, nD as reference. Depression did not influence dementia incidence. Conclusions. Present depression and, particularly, present and past depression are associated with dementia at old age. Multiple mechanisms, including toxic effect of depression on hippocampal neurons, plausibly explain these associations.

  3. Cumulative social disadvantage and child health.

    Science.gov (United States)

    Bauman, Laurie J; Silver, Ellen J; Stein, Ruth E K

    2006-04-01

    Disparities in child health are a major public health concern. However, it is unclear whether these are predominantly the result of low income, race, or other social risk factors that may contribute to their health disadvantage. Although others have examined the effects of the accumulation of risk factors, this methodology has not been applied to child health. We tested 4 social risk factors (poverty, minority race/ethnicity, low parental education, and not living with both biological parents) to assess whether they have cumulative effects on child health and examined whether access to health care reduced health disparities. We analyzed data on 57,553 children low parental education, and single-parent household) were consistently associated with child health. These were summed, generating the Social Disadvantage Index (range: 0-3). A total of 43.6% of children had no social disadvantages, 30.8% had 1, 15.6% had 2, and 10.0% had all 3. Compared with those with no social disadvantages, the odds ratios (ORs) of being in "good, fair, or poor health" (versus "excellent or very good") were 1.95 for 1 risk, 3.22 for 2 risks, and 4.06 for 3 risks. ORs of having a chronic condition increased from 1.25 (1 risk) to 1.60 (2 risks) to 2.11 (3 risks). ORs for activity limitation were 1.51 (1 risk) to 2.14 (2 risks) and 2.88 (3 risks). Controlling for health insurance did not affect these findings. The accumulation of social disadvantage among children was strongly associated with poorer child health and having insurance did not reduce the observed health disparities.

  4. Totally implantable venous catheters for chemotherapy: experience in 500 patients

    Directory of Open Access Journals (Sweden)

    Nelson Wolosker

    Full Text Available CONTEXT: Totally implantable devices are increasingly being utilized for chemotherapy treatment of oncological patients, although few studies have been done in our environment to analyze the results obtained from the implantation and utilization of such catheters. OBJECTIVE: To study the results obtained from the implantation of totally implantable catheters in patients submitted to chemotherapy. TYPE OF STUDY: Prospective. SETTING: Hospital do Câncer A.C. Camargo, São Paulo, Brazil. METHODS: 519 totally implantable catheters were placed in 500 patients submitted to chemotherapy, with preference for the use of the right external jugular vein. Evaluations were made of the early and late-stage complications and patient evolution until removal of the device, death or the end of the treatment. RESULTS: The prospective analysis showed an average duration of 353 days for the catheters. There were 427 (82.2% catheters with no complications. Among the early complications observed, there were 15 pathway hematomas, 8 cases of thrombophlebitis of the distal stump of the external jugular vein and one case of pocket infection. Among the late-stage complications observed, there were 43 infectious complications (0.23/1000 days of catheter use, 11 obstructions (0.06/1000 days of catheter use and 14 cases of deep vein thrombosis (0.07/1000 days of catheter use. Removal of 101 catheters was performed: 35 due to complications and 66 upon terminating the treatment. A total of 240 patients died while the catheter was functioning and 178 patients are still making use of the catheter. CONCLUSION: The low rate of complications obtained in this study confirms the safety and convenience of the use of totally implantable accesses in patients undergoing prolonged chemotherapy regimes.

  5. A Framework for Treating Cumulative Trauma with Art Therapy

    Science.gov (United States)

    Naff, Kristina

    2014-01-01

    Cumulative trauma is relatively undocumented in art therapy practice, although there is growing evidence that art therapy provides distinct benefits for resolving various traumas. This qualitative study proposes an art therapy treatment framework for cumulative trauma derived from semi-structured interviews with three art therapists and artistic…

  6. Cumulative Effects of Human Activities on Marine Mammal Populations

    Science.gov (United States)

    2015-09-30

    1 DISTRIBUTION STATEMENT A. Approved for public release; distribution is unlimited. Cumulative Effects of Human Activities on Marine Mammal ...marine mammals . OBJECTIVES The National Academies of Sciences, Engineering, and Medicine has convened a volunteer committee that will...Review the present scientific understanding of cumulative effects of anthropogenic stressors on marine mammals with a focus on anthropogenic sound

  7. A Framework for Treating Cumulative Trauma with Art Therapy

    Science.gov (United States)

    Naff, Kristina

    2014-01-01

    Cumulative trauma is relatively undocumented in art therapy practice, although there is growing evidence that art therapy provides distinct benefits for resolving various traumas. This qualitative study proposes an art therapy treatment framework for cumulative trauma derived from semi-structured interviews with three art therapists and artistic…

  8. Cumulative Estrogen Exposure and Prospective Memory in Older Women

    Science.gov (United States)

    Hesson, Jacqueline

    2012-01-01

    This study looked at cumulative lifetime estrogen exposure, as estimated with a mathematical index (Index of Cumulative Estrogen Exposure (ICEE)) that included variables (length of time on estrogen therapy, age at menarche and menopause, postmenopausal body mass index, time since menopause, nulliparity and duration of breastfeeding) known to…

  9. Preprocedural ultrasound examination versus manual palpation for thoracic epidural catheter insertion

    Directory of Open Access Journals (Sweden)

    Ahmed M Hasanin

    2017-01-01

    Conclusion: Preprocedural ultrasound imaging increased the incidence of first pass success in thoracic epidural catheter insertion and reduced the catheter insertion time compared to manual palpation method.

  10. Duration and Adverse Events of Non-cuffed Catheter in Patients With Hemodialysis

    Science.gov (United States)

    2014-10-09

    Renal Failure Chronic Requiring Hemodialysis; Central Venous Catheterization; Inadequate Hemodialysis Blood Flow; Venous Stenosis; Venous Thrombosis; Infection Due to Central Venous Catheter; Central Venous Catheter Thrombosis

  11. Lattice QCD results on cumulant ratios at freeze-out

    CERN Document Server

    Karsch, Frithjof

    2016-01-01

    Ratios of cumulants of net proton-number fluctuations measured by the STAR Collaboration show strong deviations from a skellam distribution, which should describe thermal properties of cumulant ratios, if proton-number fluctuations are generated in equilibrium and a hadron resonance gas (HRG) model would provide a suitable description of thermodynamics at the freeze-out temperature. We present some results on sixth order cumulants entering the calculation of the QCD equation of state at non-zero values of the baryon chemical potential (mu_B) and discuss limitations on the applicability of HRG thermodynamics deduced from a comparison between QCD and HRG model calculations of cumulants of conserved charge fluctuations. We show that basic features of the $\\mu_B$-dependence of skewness and kurtosis ratios of net proton-number fluctuations measured by the STAR Collaboration resemble those expected from a O(mu_B^2) QCD calculation of the corresponding net baryon-number cumulant ratios.

  12. A new family of cumulative indexes for measuring scientific performance.

    Directory of Open Access Journals (Sweden)

    Marcin Kozak

    Full Text Available In this paper we propose a new family of cumulative indexes for measuring scientific performance which can be applied to many metrics, including h index and its variants (here we apply it to the h index, h(2 index and Google Scholar's i10 index. These indexes follow the general principle of repeating the index calculation for the same publication set. Using bibliometric data and reviewer scores for accepted and rejected fellowship applicants we examine how valid the cumulative variant is compared to the original variant. These analyses showed that the cumulative indexes result in higher correlations with the reviewer scores than their original variants. Thus, the cumulative indexes better reflect the assessments by peers than the original variants and are useful extensions of the original indexes. In contrast to many other measures of scientific performance proposed up to now, the cumulative indexes seem not only to be effective, but they are also easy to understand and calculate.

  13. The effect of vessel depth, diameter, and location on ultrasound-guided peripheral intravenous catheter longevity.

    Science.gov (United States)

    Fields, J Matthew; Dean, Anthony J; Todman, Raleigh W; Au, Arthur K; Anderson, Kenton L; Ku, Bon S; Pines, Jesse M; Panebianco, Nova L

    2012-09-01

    Ultrasound-guided peripheral intravenous catheters (USGPIVs) have been observed to have poor durability. The current study sets out to determine whether vessel characteristics (depth, diameter, and location) predict USGPIV longevity. A secondary analysis was performed on a prospectively gathered database of patients who underwent USGPIV placement in an urban, tertiary care emergency department. All patients in the database had a 20-gauge, 48-mm-long catheter placed under ultrasound guidance. The time and reason for USGPIV removal were extracted by retrospective chart review. A Kaplan-Meier survival analysis was performed. After 48 hours from USGPIV placement, 32% (48/151) had failed prematurely, 24% (36/151) had been removed for routine reasons, and 44% (67/151) remained in working condition yielding a survival probability of 0.63 (95% confidence interval [CI], 0.53-0.70). Survival probability was perfect (1.00) when placed in shallow vessels (<0.4 cm), moderate (0.62; 95% CI, 0.51-0.71) for intermediate vessels (0.40-1.19 cm), and poor (0.29; 95% CI, 0.11-0.51) for deep vessels (≥1.2 cm); P < .0001. Intravenous survival probability was higher when placed in the antecubital fossa or forearm locations (0.83; 95% CI, 0.69-0.91) and lower in the brachial region (0.50; 95% CI, 0.38-0.61); P = .0002. The impact of vessel depth and location was significant after 3 hours and 18 hours, respectively. Vessel diameter did not affect USGPIV longevity. Cannulation of deep and proximal vessels is associated with poor USGPIV survival. Careful selection of target vessels may help improve success of USGPIV placement and durability. Copyright © 2012 Elsevier Inc. All rights reserved.

  14. Diagnosis of intra vascular catheter-related infection.

    Science.gov (United States)

    Cicalini, S; Palmieri, F; Noto, P; Boumis, E; Petrosillo, N

    2002-01-01

    The use of central vascular catheters (CVC) is associated with a substantial number of complications, amongst which infections predominate. A diagnosis of CVC-related infection usually requires catheter removal for culture. Semiquantitative (roll-plate method) and quantitative methods (flush, vortex, centrifugation or sonication methods) are the most reliable diagnostic methodologies requiring catheter removal, because of their greater specificity. The roll-plate method is the simplest and most commonly used technique. This method only samples the external surface of the catheter, and is particularly indicated for recently inserted catheters in which extraluminal colonisation is the primary mechanism of infection. Luminal culture techniques, such as the quantitative methods, may be more relevant for catheters that have been in place for a long period of time. However, in up to 85% of removed CVC the culture is negative, and other diagnostic techniques that do not require catheter removal have been proposed, including paired quantitative blood cultures, endoluminal brushing, and differential time to positivity (DTP) of paired blood cultures. DTP, that compares the time to positivity for qualitative cultures of blood samples simultaneously drawn from the CVC and a peripheral vein, appears to be the most reliable in the routine clinical practice since many hospitals use automatic devices for qualitative blood culture positivity detection. More recently catheter-sparing direct diagnostic methods, which include Gram stain and acridin-orange leucocyte cytospin (AOLC) test, appeared to be especially useful because of the rapidity of results and the ability to distinguish different microorganisms, allowing early targeted antimicrobial therapy.

  15. 21 CFR 870.1290 - Steerable catheter control system.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Steerable catheter control system. 870.1290 Section 870.1290 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES (CONTINUED) MEDICAL DEVICES CARDIOVASCULAR DEVICES Cardiovascular Diagnostic Devices § 870.1290 Steerable catheter control system. (a) Identification....

  16. 21 CFR 870.1350 - Catheter balloon repair kit.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter balloon repair kit. 870.1350 Section 870... repair kit. (a) Identification. A catheter balloon repair kit is a device used to repair or replace the... effect the repair or replacement. (b) Classification. Class III (premarket approval). (c) Date PMA...

  17. Safety and efficacy of catheter-directed thrombolysis

    DEFF Research Database (Denmark)

    Bækgaard, N; Klitfod, Lotte; Broholm, R

    2012-01-01

    To describe the background for--and mechanism of--catheter-directed thrombolysis (CDT) for iliofemoral deep venous thrombosis (DVT) accessed via the popliteal vein. Focus is on safety and efficacy.......To describe the background for--and mechanism of--catheter-directed thrombolysis (CDT) for iliofemoral deep venous thrombosis (DVT) accessed via the popliteal vein. Focus is on safety and efficacy....

  18. A magnetic-resonance-imaging-compatible remote catheter navigation system.

    Science.gov (United States)

    Tavallaei, Mohammad Ali; Thakur, Yogesh; Haider, Syed; Drangova, Maria

    2013-04-01

    A remote catheter navigation system compatible with magnetic resonance imaging (MRI) has been developed to facilitate MRI-guided catheterization procedures. The interventionalist's conventional motions (axial motion and rotation) on an input catheter - acting as the master - are measured by a pair of optical encoders, and a custom embedded system relays the motions to a pair of ultrasonic motors. The ultrasonic motors drive the patient catheter (slave) within the MRI scanner, replicating the motion of the input catheter. The performance of the remote catheter navigation system was evaluated in terms of accuracy and delay of motion replication outside and within the bore of the magnet. While inside the scanner bore, motion accuracy was characterized during the acquisition of frequently used imaging sequences, including real-time gradient echo. The effect of the catheter navigation system on image signal-to-noise ratio (SNR) was also evaluated. The results show that the master-slave system has a maximum time delay of 41 ± 21 ms in replicating motion; an absolute value error of 2 ± 2° was measured for radial catheter motion replication over 360° and 1.0 ± 0.8 mm in axial catheter motion replication over 100 mm of travel. The worst-case SNR drop was observed to be 2.5%.

  19. Port catheter fracture and migration in Internal Jugular Vein.

    Science.gov (United States)

    Doley, Rudra Prasad; Brar, Preetinder; Chaudhary, Sanchit; Bedi, Rajeev; Swami, Adarsh Chander; Wig, Jai Dev

    2012-01-01

    Central venous access devices for chemotherapy are being used extensively in patients with cancer. Spontaneous fracture and migration of the catheter is uncommon. We present the uncommon occurrence of a fracture and spontaneous migration of the fragment into the internal jugular vein as a delayed complication of a central venous access catheter implanted for chemotherapy administration. A patient with Ewing's sarcoma of the humerus with metastasis in the lungs underwent placement of a totally implantable venous access device. The port was in place for 1 year. The patient presented with pain in the right side of the neck. A chest X-ray demonstrated complete transection of the catheter and migration of the catheter fragment in the internal jugular vein. Both the migrated catheter fragment and the proximal part of the catheter were retrieved surgically. He had an uneventful recovery. Catheter fracture remains a potential complication, which must be recognized and treated promptly. Periodic chest imaging is recommended for detection and timely removal of the catheter.

  20. Strategies to Reduce Hemodialysis Catheter-related Complications

    NARCIS (Netherlands)

    Weijmer, M.C.

    2007-01-01

    The objective of the studies presented in this thesis was to reduce hemodialysis catheter-related complications by studying the influence of the following issues. In Chapter 3 we address the best cannulation site once the time period a hemodialysis catheter is needed has been estimated. We showed t

  1. Unusual migration of ventriculo peritoneal distal catheter into vagina

    Directory of Open Access Journals (Sweden)

    Sghavamedin Tavallaee

    2015-04-01

    Full Text Available VP shunt is one of the most popular methods for ICP reduction and treatment of hydrocephalus. Various complications of this method are not uncommon such as shunt malfunction, infection and unusual migration of distal catheter. I present a case of migration of the peritoneal catheter out of the vagina.

  2. 21 CFR 870.2870 - Catheter tip pressure transducer.

    Science.gov (United States)

    2010-04-01

    ... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Catheter tip pressure transducer. 870.2870 Section 870.2870 Food and Drugs FOOD AND DRUG ADMINISTRATION, DEPARTMENT OF HEALTH AND HUMAN SERVICES... pressure transducer. (a) Identification. A catheter tip pressure transducer is a device incorporated into...

  3. Difficulty in the removal of epidural catheter for labor analgesia

    Directory of Open Access Journals (Sweden)

    Mohamed S Hajnour

    2017-01-01

    Full Text Available For labor pain management epidural analgesia is a popular and an effective method. Difficult removal of epidural catheters occasionally occurs, and several maneuvers have been recommended. The purpose of this article is to raise awareness of the problem of retained epidural catheter fragments and identify the potential impact of complications.

  4. Difficulty in the removal of epidural catheter for labor analgesia.

    Science.gov (United States)

    Hajnour, Mohamed S; Khokhar, Rashid Saeed; Ejaz, Abdul Aziz Ahmed; Al Zahrani, Tariq; Kanchi, Naveed Uddin

    2017-01-01

    For labor pain management epidural analgesia is a popular and an effective method. Difficult removal of epidural catheters occasionally occurs, and several maneuvers have been recommended. The purpose of this article is to raise awareness of the problem of retained epidural catheter fragments and identify the potential impact of complications.

  5. Diagnosis and Rescue of a Kinked Pulmonary Artery Catheter

    Directory of Open Access Journals (Sweden)

    Nicolas J. Mouawad

    2015-01-01

    Full Text Available Invasive hemodynamic monitoring with a pulmonary catheter has been relatively routine in cardiovascular and complex surgical operations as well as in the management of critical illnesses. However, due to multiple potential complications and its invasive nature, its use has decreased over the years and less invasive methods such as transesophageal echocardiography and hemodynamic sensors have gained widespread favor. Unlike these less invasive forms of hemodynamic monitoring, pulmonary artery catheters require an advanced understanding of cardiopulmonary physiology, anatomy, and the potential for complications in order to properly place, manage, and interpret the device. We describe a case wherein significant resistance was encountered during multiple unsuccessful attempts at removing a patient’s catheter secondary to kinking and twisting of the catheter tip. These attempts to remove the catheter serve to demonstrate potential rescue options for such a situation. Ultimately, successful removal of the catheter was accomplished by simultaneous catheter retraction and sheath advancement while gently pulling both objects from the cannulation site. In addition to being skilled in catheter placement, it is imperative that providers comprehend the risks and complications of this invasive monitoring tool.

  6. Management of retained encrusted urethral catheter with extracorporeal shockwave lithotripsy

    Directory of Open Access Journals (Sweden)

    Sameh Anwar Kunzman

    2002-01-01

    Full Text Available We report a case of non-deflating heavily encrusted Foley catheter successfully removed by extracorporeal shockwave lithotripsy (ESWL. To our knowledge this is the first case of using ESWL to remove encrusted foley catheter retained in the bladder.

  7. Improvement of catheter quality inspection process

    Directory of Open Access Journals (Sweden)

    Bożek Mariusz

    2017-01-01

    Full Text Available Quality inspection is very often one of the most important stages of the production process, although it does not create any added value. Therefore, optimization of the related number of activities is of crucial importance. However, reduction should not be made arbitrarily, but preceded and documented by appropriate research. The article describes a study aimed at reducing the high cost of quality inspection as part of the manufacturing process of a diagnostic catheter at a medical company. The product is used for blood pressure monitoring and blood sampling by the Seldinger technique. A critical quality feature for the catheter is air/water tightness. Following a thorough analysis, some control points were eliminated, and others were improved. The resulting conclusion is that detection of defective components is the most beneficial for this specific production process if carried out during the 100 percent final quality inspection. The finding is based on the fact that the cost of producing the final device with a defective component is lower than a quality inspection run directly after each operation. The authors also managed to decrease the sample size for control charts used to supervise the adhesive connection strength.

  8. New tools in diagnosing catheter-related infections.

    Science.gov (United States)

    Blot, F; Nitenberg, G; Brun-Buisson, C

    2000-07-01

    Clinical criteria alone are insufficient to allow a diagnosis of intravascular catheter-related sepsis (CRS). A definite diagnosis of CRS usually requires removal of the catheter for quantitative catheter tip culture. However, only about 15-25% of central venous catheters (CVC) removed because infection is suspected actually prove to be infected, and the diagnosis is always retrospective. Other diagnostic tests, such as differential quantitative blood cultures from samples taken simultaneously from the catheter and a peripheral vein, have been proposed to avoid unjustified removal of the catheter and the potential risks associated with the placement of a new catheter at a new site: a central-to-peripheral blood culture colony count ratio of 5:1 to 10:1 is considered indicative of CRS. Despite its high specificity, the latter diagnostic technique is not routinely used in clinical practice because of its complexity and cost. The measurement of the differential time to positivity between hub blood (taken from the catheter port) and peripheral blood cultures might be a reliable tool facilitating the diagnosis of CRS in situ. In an in vitro study, we found a strong relationship between the inoculum size of various microorganisms and the time to positivity of cultures. When the times to positivity of cultures of blood taken simultaneously from central and peripheral veins in patients with and without CRS were examined, we found that earlier positivity of central vs peripheral vein blood cultures was highly correlated with CRS. Using a cut-off value of +120 min, the "differential time to positivity" of the paired blood samples, defined as time to positivity of the peripheral blood minus that of the hub blood culture, had 91% specificity and 94% sensitivity for the diagnosis of CRS. This method may be coupled with other techniques that have high negative predictive value, such as skin cultures at the catheter exit site. This diagnostic test can be proposed for routine

  9. The dialysis catheter and infectious peritonitis in intermittent peritoneal dialysis

    DEFF Research Database (Denmark)

    Kolmos, Hans Jørn; Hemmeløff Andersen, Karl Erik; Hansen, Lise

    1984-01-01

    118 episodes of infectious peritonitis registered among 156 patients treated with intermittent peritoneal dialysis over a 5-yr period were analysed with special reference to potential routes of infection associated with the dialysis catheter. Peritonitis was randomly distributed among the patients......, and the change of keeping free of peritonitis declined exponentially with time. The main factor determining the individual number of episodes was the total space of time, in which a patient had been wearing a dialysis catheter, whereas the number of catheter disconnections played no significant role. A relative...... preponderance of cases due to Enterobacteriaceae was noted within the first week after catheter implantation. In contrast with this, peritonitis with skin microorganisms was not associated with the implantation of catheters....

  10. An Effective Technique for Enhancing an Intrauterine Catheter Fetal Electrocardiogram

    Directory of Open Access Journals (Sweden)

    Holls III William M

    2003-01-01

    Full Text Available Physician can obtain fetal heart rate, electrophysiological information, and uterine contraction activity for determining fetal status from an intrauterine catheters electrocardiogram with the maternal electrocardiogram canceled. In addition, the intrauterine catheter would allow physicians to acquire fetal status with one non-invasive to the fetus biosensor as compared to invasive to the fetus scalp electrode and intrauterine pressure catheter used currently. A real-time maternal electrocardiogram cancellation technique of the intrauterine catheters electrocardiogram will be discussed along with an analysis for the methods effectiveness with synthesized and clinical data. The positive results from an original detailed subjective and objective analysis of synthesized and clinical data clearly indicate that the maternal electrocardiogram cancellation method was found to be effective. The resulting intrauterine catheters electrocardiogram from effectively canceling the maternal electrocardiogram could be used for determining fetal heart rate, fetal electrocardiogram electrophysiological information, and uterine contraction activity.

  11. Percutaneous catheter use in newborn infants with parenteral nutrition.

    Science.gov (United States)

    García del Río, M; Lastra-Sanchez, G; Martínez-Léon, M; Martínez-Valverde, A

    1998-12-01

    The well known negative effect of infection on nutrition causes the cycle 'infection-malnutrition-infection'. Prolonged parenteral nutrition requires central venous catheterization. Due to the possibility of 'catheter related sepsis' (CRS) catheters should be used correctly to avoid septic complications. A very high percentage of central venous catheters (CVC) removed because of presumed infections are not infected when culture is done. In some patients infections are successfully treated with antibiotics without catheter removal. Removal of the line is recommended when catheter-associated sepsis is suspected or proven, but not for the extremely ill preterm infant or when such removal may be impractical. A therapeutic protocol is suggested to avoid future canalizations in the neonate, sometimes in a critical situation. Current literature referring to CRS in the newborn infant is reviewed.

  12. A bivariate optimal replacement policy with cumulative repair cost limit under cumulative damage model

    Indian Academy of Sciences (India)

    MIN-T SAI LAI; SHIH-CHIH CHEN

    2016-05-01

    In this paper, a bivariate replacement policy (n, T) for a cumulative shock damage process is presented that included the concept of cumulative repair cost limit. The arrival shocks can be divided into two kinds of shocks. Each type-I shock causes a random amount of damage and these damages are additive. When the total damage exceeds a failure level, the system goes into serious failure. Type-II shock causes the system into minor failure and such a failure can be corrected by minimal repair. When a minor failure occurs, the repaircost will be evaluated and minimal repair is executed if the accumulated repair cost is less than a predetermined limit L. The system is replaced at scheduled time T, at n-th minor failure, or at serious failure. The long-term expected cost per unit time is derived using the expected costs as the optimality criterion. The minimum-cost policy is derived, and existence and uniqueness of the optimal n* and T* are proved. This bivariate optimal replacement policy (n, T) is showed to be better than the optimal T* and the optimal n* policy.

  13. Longhi Games, Internal Reservoirs, and Cumulate Porosity

    Science.gov (United States)

    Morse, S. A.

    2009-05-01

    Fe in plagioclase at an early age, T-rollers (or not) on the Di-Trid boundary in Fo-Di-Sil, the mantle solidus, origins of anorthosites, esoteric uses of Schreinemakers rules and many more topics are all fresh and pleasant memories of John Longhi's prolific and creative work. The Fram-Longhi experimental effect of pressure on plagioclase partitioning with liquid in mafic rocks became essential to an understanding of multiphase Rayleigh fractionation of plagioclase in big layered intrusions. Only by using the pressure effect could I find a good equation through the data for the Kiglapait intrusion, and that result among others required the existence with probability 1.0 of an internal reservoir (Morse, JPet 2008). Knowledge of cumulate porosity is a crucial key to the understanding of layered igneous rocks. We seek both the initial (inverse packing fraction) and residual porosity to find the time and process path from sedimentation to solidification. In the Kiglapait Lower Zone we have a robust estimate of mean residual porosity from the modes of the excluded phases augite, oxides, sulfide, and apatite. To this we apply the maximum variance of plagioclase composition (the An range) to find an algorithm that extends through the Upper Zone and to other intrusions. Of great importance is that all these measurements were made in grain mounts concentrated from typically about 200 g of core or hand specimen, hence the represented sample volume is thousands of times greater than for a thin section. The resulting distribution and scatter of the An range is novel and remarkable. It is V-shaped in the logarithmic representation of stratigraphic height, running from about 20 mole % at both ends (base to top of the Layered Series) to near-zero at 99 PCS. The intercept of the porosity-An range relation gives An range = 3.5 % at zero residual porosity. Petrographic analysis reveals that for PCS less than 95 and greater than 99.9, the An range is intrinsic, i.e. pre-cumulus, for

  14. Urethral catheter insertion forces: a comparison of experience and training

    Directory of Open Access Journals (Sweden)

    Benjamin K. Canales

    2009-02-01

    Full Text Available Purpose: This study was undertaken to evaluate the insertion forces utilized during simulated placement of a urethral catheter by healthcare individuals with a variety of catheter experience. Materials and Methods: A 21F urethral catheter was mounted to a metal spring. Participants were asked to press the tubing spring against a force gauge and stop when they met a level of resistance that would typically make them terminate a catheter placement. Simulated catheter insertion was repeated fives times, and peak compression forces were recorded. Healthcare professionals were divided into six groups according to their title: urology staff, non-urology staff, urology resident/ fellow, non-urology resident/ fellow, medical student, and registered nurse. Results: A total of fifty-seven healthcare professionals participated in the study. Urology staff (n = 6 had the lowest average insertion force for any group at 6.8 ± 2.0 Newtons (N. Medical students (n = 10 had the least amount of experience (1 ± 0 years and the highest average insertion force range of 10.1 ± 3.7 N. Health care workers with greater than 25 years experience used significantly less force during catheter insertions (4.9 ± 1.8 N compared to all groups (p < 0.01. Conclusions: We propose the maximum force that should be utilized during urethral catheter insertion is 5 Newtons. This force deserves validation in a larger population and should be considered when designing urethral catheters or creating catheter simulators. Understanding urethral catheter insertion forces may also aid in establishing competency parameters for health care professionals in training.

  15. Cumulative Risk for Early Sexual Initiation among American Indian Youth: A Discrete-Time Survival Analysis

    Science.gov (United States)

    Mitchell, Christina M.; Whitesell, Nancy Rumbaugh; Spicer, Paul; Beals, Janette; Kaufman, Carol E.

    2007-01-01

    Approximately 3 million teens are diagnosed with a sexually transmitted disease (STD) annually; STDs rates for American Indian young adults are among the highest of any racial/ethnic group. An important risk factor for STDs is early initiation of sex. In this study, we examined risk for early initiation with 474 American Indian youth ages 14-18,…

  16. On the Analysis of Grouped Survival Data Using Cumulative Occurrence/Exposure Rates

    Science.gov (United States)

    1991-03-01

    231-240. Marsaglia , G., Zaman, A. and Tsang, W. W. (1990). Toward a universal random number generator. Statistics and Probability Letters 8 35-39...1308 .1348 .0798 .0888 NOTES: The data were generated using the uniform random number generator of Marsaglia , Zaman and Tsang (1990). The number of

  17. Posteriorly tunneled dialysis catheters for permanent use in cognitively impaired patients undergoing hemodialysis.

    Science.gov (United States)

    Stroz, Marianne J; Nathoo, Bharat; Stroz, Peter M

    2014-10-01

    Cognitively impaired patients often pull at their dialysis catheters when the catheters are tunneled over the anterior chest. To potentially circumvent this, a technique was developed that tunnels the catheter posteriorly, over the patient's shoulder. A total of 32 posteriorly tunneled catheters were placed in 12 patients. The mean catheter use interval was 164 days, with a total of 5,248 catheter use days. Indications for nonelective catheter removals were catheter dysfunction (n = 7; 23.3%), removal by the patient (n = 7; 23.3%), infection (n = 5; 16.7%), and inadvertent dislodgment (n = 1; 3.3%). Only six of the 12 patients were able to dislodge their catheters. The procedure described here reduced catheter manipulation and extended catheter viability in these patients. Copyright © 2014 SIR. Published by Elsevier Inc. All rights reserved.

  18. Cefotaxime-heparin lock prophylaxis against hemodialysis catheter-related sepsis among Staphylococcus aureus nasal carriers

    Directory of Open Access Journals (Sweden)

    Anil K Saxena

    2012-01-01

    Full Text Available Staphylococcus aureus nasal carriers undergoing hemodialysis (HD through tunneled cuffed catheters (TCCs form a high-risk group for the development of catheter-related bloodstream infections (CRBSI and ensuing morbidity. The efficacy of antibiotic-locks on the outcomes of TCCs among S. aureus nasal carriers has not been studied earlier. Persistent nasal carriage was defined by two or more positive cultures for methicillin-susceptible (MSSA or methicillin-resistant (MRSA S. aureus of five standardized nasal swabs taken from all the participants dialyzed at a large out-patient HD center affiliated to a tertiary care hospital. Of 218 participants, 82 S. aureus nasal carriers dialyzed through TCCs (n = 88 were identified through April 2005 to March 2006 and randomized to two groups. Group I comprised of 39 nasal carriers who had TCCs (n = 41 "locked" with cefotaxime/heparin while group II included 43 patients with TCCs (n = 47 filled with standard heparin. The CRBSI incidence and TCC survival at 365 days were statistically compared between the two groups. A significantly lower CRBSI incidence (1.47 vs. 3.44/1000 catheter-days, P <0.001 and higher infection-free TCC survival rates at 365 days (80.5 vs. 40.4%, P <0.0001 were observed in the cefotaxime group compared with the stan-dard heparin group. However, no significant difference in MRSA-associated CRBSI incidence was observed between the two groups. Cefotaxime-heparin "locks" effectively reduced CRBSI-incidence associated with gram-positive cocci, including MSSA, among S. aureus nasal carriers. There remains a compelling requirement for antibiotic-locks effective against MRSA.

  19. Cumulative stress and autonomic dysregulation in a community sample.

    Science.gov (United States)

    Lampert, Rachel; Tuit, Keri; Hong, Kwang-Ik; Donovan, Theresa; Lee, Forrester; Sinha, Rajita

    2016-05-01

    Whether cumulative stress, including both chronic stress and adverse life events, is associated with decreased heart rate variability (HRV), a non-invasive measure of autonomic status which predicts poor cardiovascular outcomes, is unknown. Healthy community dwelling volunteers (N = 157, mean age 29 years) participated in the Cumulative Stress/Adversity Interview (CAI), a 140-item event interview measuring cumulative adversity including major life events, life trauma, recent life events and chronic stressors, and underwent 24-h ambulatory ECG monitoring. HRV was analyzed in the frequency domain and standard deviation of NN intervals (SDNN) calculated. Initial simple regression analyses revealed that total cumulative stress score, chronic stressors and cumulative adverse life events (CALE) were all inversely associated with ultra low-frequency (ULF), very low-frequency (VLF) and low-frequency (LF) power and SDNN (all p stress and chronic stress each was significantly associated with SDNN and ULF even after the highly significant contributions of age and sex, with no other covariates accounting for additional appreciable variance. For VLF and LF, both total cumulative stress and chronic stress significantly contributed to the variance alone but were not longer significant after adjusting for race and health behaviors. In summary, total cumulative stress, and its components of adverse life events and chronic stress were associated with decreased cardiac autonomic function as measured by HRV. Findings suggest one potential mechanism by which stress may exert adverse effects on mortality in healthy individuals. Primary preventive strategies including stress management may prove beneficial.

  20. Comparison of heparin-coated and conventional split-tip hemodialysis catheters.

    Science.gov (United States)

    Clark, Timothy W I; Jacobs, David; Charles, Hearns W; Kovacs, Sandor; Aquino, Theresa; Erinjeri, Joseph; Benstein, Judith A

    2009-07-01

    Catheter coatings have the potential to decrease infection and thrombosis in patients with chronic dialysis catheters. We report our midterm experience with a heparin-coated dialysis catheter. This retrospective, case-control study was approved by our Institutional Review Board. A total of 88 tunneled dialysis catheters were inserted over a 13-month period via the internal jugular vein. Thirty-eight uncoated split-tip catheters and 50 heparin-coated catheters were inserted. Primary catheter patency was compared between the two groups using the log rank test, with infection and/or thrombosis considered as catheter failures. Dialysis parameters during the first and last dialysis sessions, including pump speed, actual blood flow, and arterial port pressures, were compared using unpaired t-tests. Primary patency of the uncoated catheters was 86.0 +/- 6.5% at 30 days and 76.1 +/- 8.9% at 90 days. Primary patency of heparin-coated catheters was 92.0 +/- 6.2% at 30 days and 81.6 +/- 8.0% at 90 days (p = 0.87, log rank test). Infection requiring catheter removal occurred in four patients with uncoated catheters and two patients with heparin-coated catheters (p = 0.23). Catheter thrombosis requiring catheter replacement or thrombolysis occurred in one patient with an uncoated catheter and two patients with heparin-coated catheters (p = 0.9). No differences in catheter function during hemodialysis were seen between the two groups. In conclusion, the heparin-coated catheter did not show a significantly longer patency compared to the uncoated catheter. The flow characteristics of this device were comparable to those of the conventional uncoated catheter. A demonstrable benefit of the heparin-coated catheter in randomized trials is needed before a recommendation for routine implementation can be made.

  1. Use of indwelling pleural catheters for the definitive treatment of malignant pleural effusion

    Directory of Open Access Journals (Sweden)

    Fernando Conrado Abrão

    Full Text Available ABSTRACT Objective: To evaluate the safety and feasibility of the use of indwelling pleural catheters (IPCs in patients with malignant pleural effusion (MPE. Methods: We prospectively collected data from patients with MPE undergoing IPC placement between January of 2014 and July of 2015. All patients submitted to IPC placement had a life expectancy > 30 days, in accordance with the MPE treatment guidelines established by the British Thoracic Society. The data collected included gender, age, body mass index, primary cancer site, duration of IPC drainage, IPC-related complications, length of hospital stay, pleural effusion recurrence, and occurrence of spontaneous pleurodesis. Results: A total of 19 patients underwent IPC placement during the study period. Median overall survival after IPC insertion was 145 days. The median follow-up among the surviving patients was 125 days (range, 53-485 days, and the median time between catheter insertion and removal was 31 days (range, 2-126 days. There were IPC-related complications in 5 patients (26.2%, and spontaneous pleurodesis was achieved in 8 (42.0%. Among those 8 patients, the IPC was removed between days 30 and 126 in 4, and spontaneous pleurodesis occurred within the first 30 days in 4. Conclusions: The use of IPCs seems to be feasible and safe in patients with MPE.

  2. Teflon-buttressed sutures plus pericardium patch repair left ventricular rupture caused by radiofrequency catheter ablation

    Science.gov (United States)

    Cao, Hao; Zhang, Qi; He, Yanzhong; Feng, Xiaodong; Liu, Zhongmin

    2016-01-01

    Abstract Background: Cardiac rupture often occurs after myocardial infarction or chest trauma with a high mortality rate. However, left ventricular rupture caused by radiofrequency catheter ablation (RFCA) is extremely rare. Methods: We describe a case of a 61-year-old male who survived from left ventricular rupture caused by a RFCA procedure for frequent ventricular premature contractions. Surgical exploration with cardiopulmonary bypass (CPB) was performed when the signs of cardiac tamponade developed 7 hours after the ablation surgery. Results: Teflon-buttressed sutures of the tear in the left ventricular posterolateral wall and pericardium patch applied to the contusion region on the wall repaired the rupture safely and effectively. Conclusion: Timely surgical intervention under CPB facilitated the survival of the patient. Teflon-buttressed sutures plus pericardium patch achieved the successful repair of the rupture. PMID:27661047

  3. Surviving Objects

    OpenAIRE

    Murjas, Teresa

    2012-01-01

    Surviving Objects (2012) is a devised multi-media practice-as-research performance based on extensive interviews conducted with my elderly mother and recorded on a hand-held device. Our conversations concern her experiences as a child refugee following violent deportation by the Soviet Army from Eastern Poland to Siberia (1941), and her subsequent route, via Persia, to a British-run refugee camp in Northern Rhodesia, where she remained for 6 years before arriving in the UK. In order to aid my...

  4. Effect of a second-generation venous catheter impregnated with chlorhexidine and silver sulfadiazine on central catheter-related infections: a randomized, controlled trial.

    Science.gov (United States)

    Rupp, Mark E; Lisco, Steven J; Lipsett, Pamela A; Perl, Trish M; Keating, Kevin; Civetta, Joseph M; Mermel, Leonard A; Lee, David; Dellinger, E Patchen; Donahoe, Michael; Giles, David; Pfaller, Michael A; Maki, Dennis G; Sherertz, Robert

    2005-10-18

    Central venous catheter-related infections are a significant medical problem. Improved preventive measures are needed. To ascertain 1) effectiveness of a second-generation antiseptic-coated catheter in the prevention of microbial colonization and infection; 2) safety and tolerability of this device; 3) microbiology of infected catheters; and 4) propensity for the development of antiseptic resistance. Multicenter, randomized, double-blind, controlled trial. 9 university-affiliated medical centers. 780 patients in intensive care units who required central venous catheterization. Patients received either a standard catheter or a catheter coated with chlorhexidine and silver sulfadiazine. The authors assessed catheter colonization and catheter-related infection, characterized microbes by molecular typing, and determined their susceptibility to antiseptics. Patient tolerance of the catheter was monitored. Patients with the 2 types of catheters had similar demographic features, clinical interventions, laboratory values, and risk factors for infection. Antiseptic catheters were less likely to be colonized at the time of removal compared with control catheters (13.3 vs. 24.1 colonized catheters per 1000 catheter-days; P < 0.01). The center-stratified Cox regression hazard ratio for colonization controlling for sampling design and potentially confounding variables was 0.45 (95% CI, 0.25 to 0.78). The rate of definitive catheter-related bloodstream infection was 1.24 per 1000 catheter-days (CI, 0.26 to 3.62 per 1000 catheter-days) for the control group versus 0.42 per 1000 catheter-days (CI, 0.01 to 2.34 per 1000 catheter-days) for the antiseptic catheter group (P = 0.6). Coagulase-negative staphylococci and other gram-positive organisms were the most frequent microbes to colonize catheters. Noninfectious adverse events were similar in both groups. Antiseptic susceptibility was similar for microbes recovered from either group. The antiseptic catheter was not compared with an

  5. Entanglement entropy and particle number cumulants of disordered fermions

    Science.gov (United States)

    Burmistrov, I. S.; Tikhonov, K. S.; Gornyi, I. V.; Mirlin, A. D.

    2017-08-01

    We study the entanglement entropy and particle number cumulants for a system of disordered noninteracting fermions in d dimensions. We show, both analytically and numerically, that for a weak disorder the entanglement entropy and the second cumulant (particle number variance) are proportional to each other with a universal coefficient. The corresponding expressions are analogous to those in the clean case but with a logarithmic factor regularized by the mean free path rather than by the system size. We also determine the scaling of higher cumulants by analytical (weak disorder) and numerical means. Finally, we predict that the particle number variance and the entanglement entropy are nonanalytic functions of disorder at the Anderson transition.

  6. Decreasing catheter-related infection and hospital costs by continuous quality improvement.

    Science.gov (United States)

    Civetta, J M; Hudson-Civetta, J; Ball, S

    1996-10-01

    a) To reduce the rate of catheter-related infection, using improved skin preparation and catheters impregnated with silver sulfadiazine and chlorhexidine; b) to decrease the number of unnecessary guidewire exchanges of existing catheters by substituting suspected catheter-related sepsis for fever alone as an indication to change an indwelling catheter; and c) to decrease the hospital costs associated with guidewire exchanges and new catheter insertions. Sequential, prospective, descriptive studies using a continuous quality management approach. A 20-bed trauma intensive care unit at a university teaching hospital. Patients (n = 147) admitted from July 1 to December 31, 1992 (phase 1); 34 patients admitted in June and September 1993 (phase 2); and 156 patients admitted between January 1 and June 30, 1994 (phase 3). Phase 1: Proportions of catheter-related infections and catheter-related bacteremia were compared with our prior reported results. Indications for guidewire exchange were analyzed, and the rate of catheter-related infection for each indication was derived. Phase 2: The rate of catheter-related infection was determined for a trial group of triple-lumen catheters impregnated with silver sulfadiazine and chlorhexidine. Phase 3: Four components were altered. Impregnated triple-lumen catheters were used instead of unprotected catheters. Chlorhexidine skin cleanser was substituted for povidone-iodine solution during initial aseptic preparation during catheter insertion and subsequent guidewire exchange. Suspected catheter-related sepsis was substituted for fever as an indication for guidewire exchange. The "safe" period (the time before considering changing a catheter because catheter-related sepsis was suspected) was extended from 2 to 4 days. The overall rate of catheter-related infection in phase 1 was 15% (15% for triple-lumen catheters and 16% for introducers). Catheters changed for site inflammation had a 46% rate of catheter-related infection

  7. A breakthrough technique for the removal of a hemodialysis catheter stuck in the central vein: endoluminal balloon dilatation of the stuck catheter.

    Science.gov (United States)

    Hong, Joon Ho

    2011-01-01

    Hemodialysis (HD) catheters can get stuck in the central vein after long-term use and their removal might become difficult especially in patients with fibrosed or occluded central veins. Herein, a breakthrough technique is reported for the easy removal of a stuck HD catheter from the central vein. Attempts were made to remove a tunneled double-lumen HD catheter from the central vein of a 74-year-old woman, only to find that the catheter was stuck. The patient was transferred to the operating room and a skin incision was made in the neck and the subcutaneous portion of the HD catheter was retrieved from the tunnel. Under fluoroscopy, a guide wire was inserted into one lumen of the HD catheter and advanced into the right atrium beyond the catheter tip. A 5 mm × 4 cm balloon angioplasty catheter was then inserted into the HD catheter lumen over the guide wire and advanced into the jugular vein junction of the HD catheter around the thoracic inlet. The balloon was inflated to its maximum dimension and pressure. This endoluminal dilatation of the HD catheter was continued by deflating the balloon and then pushing the angioplasty catheter 4 cm at a time towards the tip of the HD catheter in the right atrium. After a second balloon angioplasty catheter of 6 mm × 4 cm was used to expand the entire segment of the other lumen, the HD catheter was pulled out easily from the central vein without any resistance. The endoluminal balloon dilatation of the HD catheter not only separates the stuck HD catheter from the adherent vein by breaking the adhesions between them, but also expands the vein simultaneously, thus enabling easy removal of the HD catheter.

  8. Central venous catheter insertion problem solving using intravenous catheter: technical communication

    Directory of Open Access Journals (Sweden)

    Alemohammad M

    2013-02-01

    Full Text Available Insertion of central venous catheter is an accepted method for hemodynamic monitor-ring, drug and fluid administration, intravenous access, hemodialysis and applying cardiac pace-maker in hospitalized patients. This procedure can be associated with severe complications. The aim of this article is to provide a practical approach to prevent catheter malposition in states that the guide wire will not pass freely.During central venous insertion in internal jugular vein using modified seldinger technique, when after venous insertion, the passage of the guide wire shows difficulties and don’t pass freely, insertion of an intravenous cannula over the wire and re-insertion of the wire can help to prevent malposition of the wire and the catheter. Use of an intravenous cannula over the guide, in situations that the guide wire cannot pass freely among the needle inserted in internal jugular vein, and re-insertion of the guide can probably prevent or reduce the tissue or vascular trauma and the associated complica-tions. This simple maneuver can be helpful in difficult cases especially in cardiac surgery patients who receive high dose heparin and it is necessary to avoid traumatize-tion of carotid artery.

  9. Protecting short-term intravascular ear catheters in healthy rabbits.

    Science.gov (United States)

    Sampieri, Francesca; Orchard, Rekha N; Antonopoulos, Aphroditi J; Hamilton, Donald L

    2012-01-20

    Researchers may place a catheter in the ear vessel of a rabbit for a short period of time in order to collect repeated blood samples without extensive restraint of the animal. Maintaining such a catheter in a healthy rabbit can be challenging, as the animal may scratch at the ear, removing the catheter or forming a large hematoma that might impede blood sampling. The authors developed a technique for protecting the indwelling catheter by cutting a section of moleskin to the same shape as the ear and gluing it to the surface of the ear and the catheter. They applied this technique to collect multiple blood samples during 12-h periods from nine rabbits in a pharmacokinetics study. Catheters remained patent in five rabbits for 12 h, in two rabbits for 8 h, in one rabbit for 6 h and in one rabbit for 4 h. This technique allowed for collection of repeated blood samples and prevented the rabbits from interfering with the catheter while allowing them to move freely during the sampling period.

  10. Percutaneous catheter drainage of intraabdominal abscesses and fluid

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Jong Tae; Kwon, Tae Hee; Yoo, Hyung Sik; Suh, Jung Ho [Yonsei University College of Medicine, Seoul (Korea, Republic of); Lee, Young Ho [Cheil General Hospital, Seoul (Korea, Republic of)

    1986-10-15

    Percutaneous catheter drainage has been reported to be an effective method in the management of selected patients with abscess and fluid collection. Its high success rate and relatively low complications make the procedure an alternative to surgery in the individual cases. During past two years percutaneous catheter drainage in 25 patients with intraabdominal abscesses and fluid collection was performed at the Department of Radiology, Yonsei University College of medicine. Here the technique and author's results were summarized. 1. The total 25 patients who had percutaneous catheter drainage are 10 liver abscesses, 3 subphrenic, one subhepatic, 4 renal and perirenal, 2 pelvic, one psoas, one anterior pararenal fluid from acute pancreatitis, one pancreas pseudocyst and 2 malignant tumor necrosis. 2. The modified Seldinger technique used for all cases of abscess and fluid drainage under guidance of ultrasound scan. The used catheters were 10F. Pigtail and 14F. Malecot (Cook c/o) catheters. 3. The abscesses and fluid of 17 patients among 25 were cured by the percutaneous catheter drainage and 4 patients were clinically improved. The catheter drainage was failed in 2 patients and 3 complication were developed. 4. The success rate of this procedure was 91.3%, failure rate was 8.7% and complication rate was 12%.

  11. Usefulness of multifunctional gastrointestinal coil catheter for colorectal stent placement

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Tae-Hyung; Shin, Ji Hoon; Kim, Jin Hyoung; Lim, Jin-Oh; Kim, Kyung Rae [Asan Medical Center, Radiology and Research Institute of Radiology, Seoul (Korea); Song, Ho-Young [Asan Medical Center - Radiology, Songpa-gu, Seoul (Korea); Park, In Kook [Dongguk University, Life Science, Seoul (Korea); Choi, Eugene K. [Weill Medical College of Cornell University, New York, NY (United States)

    2008-11-15

    The purpose of this study was to evaluate the usefulness of a multifunctional gastrointestinal coil catheter for stent placement in 98 patients with colorectal strictures. The catheter was used in 98 consecutive patients for stent placement in the rectum (n = 24), recto-sigmoid (n = 13), sigmoid (n = 38), descending (n = 6), transverse (n = 11), splenic flexure (n = 3), hepatic flexure (n = 2), and ascending (n = 1) colon. The catheter was made of a stainless steel coil (1.3 mm in inner diameter), a 0.4-mm nitinol wire, a polyolefin tube, and a hemostasis valve. Usefulness of the catheter was evaluated depending on whether the catheter could pass a stricture over a guide wire and whether measurement of the stricture length was possible. The passage of the catheter over a guide wire beyond the stricture was technically successful and well tolerated in 93 (94.9%) of 98 patients. In the failed five patients, it was not possible to negotiate the guide wire due to presence of nearly complete small bowel obstruction. The average length of stricture was 6.15 cm (range, 3 cm to 20 cm) in patients with the colorectal stricture. There were no procedure-related complications. In conclusion, the multifunctional coil catheter seems to be useful in colorectal stent placement. (orig.)

  12. Distributed parameter statics of magnetic catheters.

    Science.gov (United States)

    Tunay, Ilker

    2011-01-01

    We discuss how to use special Cosserat rod theory for deriving distributed-parameter static equilibrium equations of magnetic catheters. These medical devices are used for minimally-invasive diagnostic and therapeutic procedures and can be operated remotely or controlled by automated algorithms. The magnetic material can be lumped in rigid segments or distributed in flexible segments. The position vector of the cross-section centroid and quaternion representation of an orthonormal triad are selected as DOF. The strain energy for transversely isotropic, hyperelastic rods is augmented with the mechanical potential energy of the magnetic field and a penalty term to enforce the quaternion unity constraint. Numerical solution is found by 1D finite elements. Material properties of polymer tubes in extension, bending and twist are determined by mechanical and magnetic experiments. Software experiments with commercial FEM software indicate that the computational effort with the proposed method is at least one order of magnitude less than standard 3D FEM.

  13. Duration of temporary catheter use for hemodialysis: an observational, prospective evaluation of renal units in Brazil

    Directory of Open Access Journals (Sweden)

    Bonfante Gisele MS

    2011-11-01

    Full Text Available Abstract Background For chronic hemodialysis, the ideal permanent vascular access is the arteriovenous fistula (AVF. Temporary catheters should be reserved for acute dialysis needs. The AVF is associated with lower infection rates, better clinical results, and a higher quality of life and survival when compared to temporary catheters. In Brazil, the proportion of patients with temporary catheters for more than 3 months from the beginning of therapy is used as an evaluation of the quality of renal units. The aim of this study is to evaluate factors associated with the time between the beginning of hemodialysis with temporary catheters and the placement of the first arteriovenous fistula in Brazil. Methods This is an observational, prospective non-concurrent study using national administrative registries of all patients financed by the public health system who began renal replacement therapy (RRT between 2000 and 2004 in Brazil. Incident patients were eligible who had hemodialysis for the first time. Patients were excluded who: had hemodialysis reportedly started after the date of death (inconsistent database; were younger than 18 years old; had HIV; had no record of the first dialysis unit; and were dialyzed in units with less than twenty patients. To evaluate individual and renal unit factors associated with the event of interest, the frailty model was used (N = 55,589. Results Among the 23,824 patients (42.9% who underwent fistula placement in the period of the study, 18.2% maintained the temporary catheter for more than three months until the fistula creation. The analysis identified five statistically significant factors associated with longer time until first fistula: higher age (Hazard-risk - HR 0.99, 95% CI 0.99-1.00; having hypertension and cardiovascular diseases (HR 0.94, 95% CI 0.9-0.98 as the cause of chronic renal disease; residing in capitals cities (HR 0.92, 95% CI 0.9-0.95 and certain regions in Brazil - South (HR 0.83, 95% CI 0

  14. A COMPARATIVE ANALYSIS OF PERCUTANEOUS AND OPEN SURGICAL TECHNIQUESFOR PERITONEAL CATHETER PLACEMENT.

    LENUS (Irish Health Repository)

    Medani, Samar

    2012-05-01

    BACKGROUND: Peritoneal dialysis (PD) is the preferred available option of renal replacement therapy for a significant number of end-stage kidney disease patients. A major limiting factor to the successful continuation of PD is the long-term viability of the PD catheter (PDC). Bedside percutaneous placement of the PDC is not commonly practiced despite published data encouraging use of this technique. Its advantages include faster recovery and avoidance of general anesthesia.♢ METHODS: We carried out a retrospective analysis of the outcomes of 313 PDC insertions at our center, comparing all percutaneous PDC insertions between July 1998 and April 2010 (group P, n = 151) with all surgical PDC insertions between January 2003 and April 2010 (group S, n = 162).♢ RESULTS: Compared with group P patients, significantly more group S patients had undergone previous abdominal surgery or PDC insertion (41.8% vs 9.3% and 33.3% vs 3.3% respectively, p = 0.00). More exit-site leaks occurred in group P than in group S (20.5% vs 6.8%, p = 0.002). The overall incidence of peritonitis was higher in group S than in group P (1 episode in 19 catheter-months vs 1 episode in 26 catheter-months, p = 0.017), but the groups showed no significant difference in the peritonitis rate within 1 month of catheter insertion (5% in group P vs 7.4% in group S, p =0.4) or in poor initial drainage or secondary drainage failure (9.9% vs 11.7%, p = 0.1, and 7.9% vs 12.3%, p = 0.38, for groups P and S respectively). Technical survival at 3 months was significantly better for group P than for group S (86.6% vs 77%, p = 0.037); at 12 months, it was 77.7% and 68.7% respectively (p = 0.126). No life-threatening complications attributable to the insertion of the PDC occurred in either group.♢ CONCLUSIONS: Our analysis demonstrates further encouraging outcomes of percutaneous PDC placement compared with open surgical placement. However, the members of the percutaneous insertion group were primarily a

  15. Duration of temporary catheter use for hemodialysis: an observational, prospective evaluation of renal units in Brazil.

    Science.gov (United States)

    Bonfante, Gisele M S; Gomes, Isabel C; Andrade, Eli Iola G; Lima, Eleonora M; Acurcio, Francisco A; Cherchiglia, Mariângela L

    2011-11-17

    For chronic hemodialysis, the ideal permanent vascular access is the arteriovenous fistula (AVF). Temporary catheters should be reserved for acute dialysis needs. The AVF is associated with lower infection rates, better clinical results, and a higher quality of life and survival when compared to temporary catheters. In Brazil, the proportion of patients with temporary catheters for more than 3 months from the beginning of therapy is used as an evaluation of the quality of renal units. The aim of this study is to evaluate factors associated with the time between the beginning of hemodialysis with temporary catheters and the placement of the first arteriovenous fistula in Brazil. This is an observational, prospective non-concurrent study using national administrative registries of all patients financed by the public health system who began renal replacement therapy (RRT) between 2000 and 2004 in Brazil. Incident patients were eligible who had hemodialysis for the first time. Patients were excluded who: had hemodialysis reportedly started after the date of death (inconsistent database); were younger than 18 years old; had HIV; had no record of the first dialysis unit; and were dialyzed in units with less than twenty patients. To evaluate individual and renal unit factors associated with the event of interest, the frailty model was used (N = 55,589). Among the 23,824 patients (42.9%) who underwent fistula placement in the period of the study, 18.2% maintained the temporary catheter for more than three months until the fistula creation. The analysis identified five statistically significant factors associated with longer time until first fistula: higher age (Hazard-risk - HR 0.99, 95% CI 0.99-1.00); having hypertension and cardiovascular diseases (HR 0.94, 95% CI 0.9-0.98) as the cause of chronic renal disease; residing in capitals cities (HR 0.92, 95% CI 0.9-0.95) and certain regions in Brazil - South (HR 0.83, 95% CI 0.8-0.87), Midwest (HR 0.88, 95% CI 0

  16. Is Taurolidine-citrate an effective and cost-effective hemodialysis catheter lock solution? A systematic review and cost- effectiveness analysis.

    Science.gov (United States)

    Kavosi, Zahra; Sarikhani Khorrami, Maryam; Keshavarz, Khosro; Jafari, Abdosaleh; Hashemi Meshkini, Amir; Safaei, Hamid Reza; Nikfar, Shekoufeh

    2016-01-01

    Prevention of catheter-related infection is of prime importance,. However, because of the risks caused by the leakage of circulating antibiotics and development of resistance to antibiotics, they are replaced by lock solutions. The aim of this study was to evaluate the efficacy and cost- effectiveness of taurolidine-citrate as a hemodialysis catheter lock solution compared to other common alternatives in Iran. To evaluate the efficacy of taurolidine-citrate, a systematic review was conducted by searching electronic databases. The outcomes of interest for cost-effectiveness analysis were as follows: "Catheter-related bacteremia episodes"; "catheter-related bacteremia-free survival"; "catheter thrombosis rate" for efficacy evaluation and "reduction of catheter-related infection". For evidence synthesis, a meta-analysis was conducted on the extracted efficacy data. To evaluate the cost of treatments, direct medical costs were included, and the incremental cost-effectiveness ratio was calculated for each comparison. The payers' (patients and insurance companies) perspectives were used for cost analysis. After carrying out the systematic process, three articles were included in the analysis. Considering 95% confidence interval, the relative difference was -0.16 (-0.25 to -0.07) for catheterrelated bacteremia episode, indicating that the rate of catheter-related infections in hemodialysis patients who used taurolidine-citrate was 16% less than in those hemodialysis patients who received heparin. Considering 95% confidence interval, the relative difference was 0.13 (-0.06 0.32) for catheter thrombosis, showing that the rate of catheter-related thrombosis in hemodialysis patients who used taurolidine-citrate was 13% more than in hemodialysis patients who received heparin. The results of this analysis indicated that taurolidine-citrate, compared to heparin, was more effective in preventing catheter-related infection; therefore, it could be considered as a superior strategy

  17. Cessation of In-line Filters in Central Venous Catheters Does Not Significantly Influence the Incidence of Bloodstream Infections and Mortality in a Hospital Hematological Ward.

    Science.gov (United States)

    Tanaka, Hiroaki; Ambiru, Satoshi; Kawaguchi, Takeharu; Sugita, Yasumasa; Kawajiri, Chika; Nagao, Yuhei; Shimura, Takenori

    2016-01-01

    Objective The use of intravenous in-line filters is effective for the mechanical removal of large particles, precipitates, bacteria, fungi, large lipid globules, and air. However, the routine use of in-line filters remains controversial. Many patients with hematological diseases frequently suffer from bloodstream infections (BSIs) with fatal outcomes. Methods The year before cessation of an in-line filter was defined as the "filter period" and the year after its cessation was defined as the "non-filter period." The number of central line-associated bloodstream infections (CLABSIs), which are defined through surveillance, the catheter utilization rate, the number of patient deaths within 7 days after removal of the central venous catheters (CVCs), and the overall survival rate following CVC insertion were measured. Results During both periods, 84 patients had a total of 140 CVCs with a total number of catheter days of 3,407. There were 10 CVCs with CLABSIs, and the overall CLABSI rate was 2.9/1,000 catheter days, including 4 CVCs with CLABSIs (2.5/1,000 catheter days) during the filter period and 6 CVCs with CLABSIs (3.3/1,000 catheter days) during the non-filter period. The CLABSI rate, catheter utilization rate, and mortality did not differ significantly between the two periods. The only independent variable that was found to be significantly associated with the development of CLABSIs was a neutrophil count of line filters from CVCs does not significantly influence the incidence of BSIs and mortality in patients with hematological disease. To confirm our results, however, a large-scale randomized controlled study is warranted.

  18. Steerable Catheter Microcoils for Interventional MRI: Reducing Resistive Heating

    Science.gov (United States)

    Bernhardt, Anthony; Wilson, Mark W.; Settecase, Fabio; Evans, Leland; Malba, Vincent; Martin, Alastair J.; Saeed, Maythem; Roberts, Timothy P. L.; Arenson, Ronald L.; Hetts, Steven W.

    2010-01-01

    PURPOSE To assess resistive heating of microwires used for remote catheter steering in interventional magnetic resonance imaging. To investigate the use of alumina to facilitate heat transfer to saline flowing in the catheter lumen. MATERIALS AND METHODS A microcoil was fabricated using a laser lathe onto polyimide-tipped or alumina-tipped endovascular catheters. In vitro testing was performed in a 1.5 T MR system using a vessel phantom, body RF coil, and steady state pulse sequence. Resistive heating was measured with water flowing over a polyimide tip catheter, or saline flowing through the lumen of an alumina-tip catheter. Preliminary in vivo testing in porcine common carotid arteries was conducted with normal blood flow or after arterial ligation when current was applied to an alumnia-tip catheter for up to 5 minutes. RESULTS After application of up to 1 W of DC power, clinically significant temperature increases were noted with the polyimide-tip catheter: 23°C/W at zero flow, 13°C/W at 0.28 cc/s, and 7.9°C/W at 1 cc/s. Using the alumina-tip catheter, the effluent temperature rise using the lowest flow rate (0.12 cc/s) was 2.3°C/W. In vivo testing demonstrated no thermal injury to vessel walls at normal and zero arterial flow. CONCLUSION Resistive heating in current carrying wire pairs can be dissipated by saline coolant flowing within the lumen of a catheter tip composed of material that facilitates heat transfer. PMID:21075017

  19. Online Scheduling in Manufacturing A Cumulative Delay Approach

    CERN Document Server

    Suwa, Haruhiko

    2013-01-01

    Online scheduling is recognized as the crucial decision-making process of production control at a phase of “being in production" according to the released shop floor schedule. Online scheduling can be also considered as one of key enablers to realize prompt capable-to-promise as well as available-to-promise to customers along with reducing production lead times under recent globalized competitive markets. Online Scheduling in Manufacturing introduces new approaches to online scheduling based on a concept of cumulative delay. The cumulative delay is regarded as consolidated information of uncertainties under a dynamic environment in manufacturing and can be collected constantly without much effort at any points in time during a schedule execution. In this approach, the cumulative delay of the schedule has the important role of a criterion for making a decision whether or not a schedule revision is carried out. The cumulative delay approach to trigger schedule revisions has the following capabilities for the ...

  20. Cumulative Risks of Foster Care Placement for Danish Children

    DEFF Research Database (Denmark)

    Fallesen, Peter; Emanuel, Natalia; Wildeman, Christopher

    2014-01-01

    Although recent research suggests that the cumulative risk of foster care placement is far higher for American children than originally suspected, little is known about the cumulative risk of foster care placement in other countries, which makes it difficult to gauge the degree to which factor...... is for Danish children. Results suggest that at the beginning of the study period (in 1998) the cumulative risk of foster care placement for Danish children was roughly in line with the risk for American children. Yet, by the end of the study period (2010), the risk had declined to half the risk for American...... foster care placement is salient in other contexts. In this article, we provide companion estimates to those provided in recent work on the US by using Danish registry data and synthetic cohort life tables to show how high and unequally distributed the cumulative risk of foster care placement...

  1. Mapping cumulative human impacts in the eastern North Sea

    DEFF Research Database (Denmark)

    Stock, A.; Andersen, Jesper; Heinänen, S.

    of the MSFD; and 3) to deepen the understanding of how errors in expert judgment affect the resulting cumulative human impact maps by means of Monte Carlo simulations. We combined existing data sets on the spatial distribution of 33 anthropogenic stressors (linked to the MSFD pressures) and 28 key habitats....... In contrast, the predicted impacts for much of the Norwegian EEZ and areas far offshore were lower. The Monte Carlo simulations confirmed earlier findings that mapping cumulative impacts is generally "robust", but also showed that specific combinations of errors can seriously change local and regional...... on marine ecosystems have only recently been developed. The aims of our study were: 1) to develop a map of cumulative human impacts for the Danish, Swedish, Norwegian and German parts of the Greater North Sea; 2) to adjust the existing methods for mapping cumulative human impacts to fit the requirements...

  2. Cumulative Production Per Township - SaMiRa

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — This dataset contains a selected township grid within the Sagebrush Mineral Resource Assessment project (SaMiRa) study area attributed with cumulative oil and gas...

  3. Cumulative radiation exposure in children with cystic fibrosis.

    LENUS (Irish Health Repository)

    O'Reilly, R

    2010-02-01

    This retrospective study calculated the cumulative radiation dose for children with cystic fibrosis (CF) attending a tertiary CF centre. Information on 77 children with a mean age of 9.5 years, a follow up time of 658 person years and 1757 studies including 1485 chest radiographs, 215 abdominal radiographs and 57 computed tomography (CT) scans, of which 51 were thoracic CT scans, were analysed. The average cumulative radiation dose was 6.2 (0.04-25) mSv per CF patient. Cumulative radiation dose increased with increasing age and number of CT scans and was greater in children who presented with meconium ileus. No correlation was identified between cumulative radiation dose and either lung function or patient microbiology cultures. Radiation carries a risk of malignancy and children are particularly susceptible. Every effort must be made to avoid unnecessary radiation exposure in these patients whose life expectancy is increasing.

  4. Macroscopic cumulative fatigue damage of material under nonsymmetrical cycle

    Institute of Scientific and Technical Information of China (English)

    盖秉政

    2002-01-01

    Hashin's macroscopic theory of fatigue damage is further discussed and a new method has been proposed for prediction of cumulative fatigue damage of material and its lifetime under nonsymmetrical cyclic loading.

  5. Translation-Invariant Representation for Cumulative Foot Pressure Images

    CERN Document Server

    Zheng, Shuai; Tan, Tieniu

    2010-01-01

    Human can be distinguished by different limb movements and unique ground reaction force. Cumulative foot pressure image is a 2-D cumulative ground reaction force during one gait cycle. Although it contains pressure spatial distribution information and pressure temporal distribution information, it suffers from several problems including different shoes and noise, when putting it into practice as a new biometric for pedestrian identification. In this paper, we propose a hierarchical translation-invariant representation for cumulative foot pressure images, inspired by the success of Convolutional deep belief network for digital classification. Key contribution in our approach is discriminative hierarchical sparse coding scheme which helps to learn useful discriminative high-level visual features. Based on the feature representation of cumulative foot pressure images, we develop a pedestrian recognition system which is invariant to three different shoes and slight local shape change. Experiments are conducted on...

  6. The natural history of tunneled hemodialysis catheters removed or exchanged: a single-institution experience.

    Science.gov (United States)

    Alomari, Ahmad I; Falk, Abigail

    2007-02-01

    To track the natural history of tunneled hemodialysis catheters requiring removal or exchange at a single institution. Over a 2-year period, tunneled hemodialysis catheters that presented to interventional radiology for removal or exchange were entered into this retrospective study. Patient demographics, catheter location, dwell time, and indication for removal were recorded. Pull-back contrast venography was performed with imaging over the chest. Catheters were then removed or exchanged. Three hundred thirty-four tunneled dialysis catheters were removed or exchanged in 207 patients; 108 male, median age 53 years. Dwell time, available from 296 catheters, ranged from 1 to 114 days (median, 66 days) for a total of 32,847 catheter days. One hundred three catheters were removed for infection, yielding a rate of infection requiring catheter removal of 3.0 per 1,000 catheter days. One hundred catheters were removed for other working access, and 96 catheters were exchanged for poor function. Two hundred sixty-five were removed or exchanged from the internal jugular vein, 22 from the subclavian vein, and 24 from the femoral vein. One hundred seventy-two (76%) of the 226 catheters studied with contrast had fibrin sheaths; of which 42 had thrombus identified along the catheter tract. One hundred ninety-three catheters were removed, and 141 catheters were exchanged for new catheters with 82 catheters receiving balloon disruption of the fibrin sheath. Approximately one third of tunneled dialysis catheters are removed for infection, one third for other working access, and one third for poor function. Catheters usually remain in the patient for a median of 2 months. Fibrin sheaths associated with hemodialysis catheters are very common. Thrombus formation around the sheath is frequent.

  7. Higher cumulative revision rate of knee arthroplasties in younger patients with osteoarthritis.

    Science.gov (United States)

    Harrysson, Ola L A; Robertsson, Otto; Nayfeh, Jamal F

    2004-04-01

    This study was designed to test the hypothesis that younger patients treated for osteoarthritis and similar conditions using total knee arthroplasty and unicompartmental knee arthroplasty have a lower implant survival rate when compared with older patients. Previous studies have been done on a small number of patients and only included the younger patients. In many cases patients treated for rheumatoid arthritis have been included in the studies and exceptional survival rates have been reported. The current study compared the cumulative revision rate of the components in 33,251 patients older than 60 years and 2606 patients younger than 60 years treated with total knee arthroplasty or unicompartmental knee arthroplasty for osteoarthritis or similar conditions. Cox regression was used to compare the risk for revision between the two age groups and between gender and the effect of year of operation. The results showed a higher cumulative revision rate for the group of younger patients in all statistical analyses and the risk ratio for revision was significantly lower for the group of older patients. The risk for revision decreased for both groups when considering the year of surgery. This is probably attributable to better implant components and surgical techniques.

  8. Hematologic patients' clinical and psychosocial experiences with implanted long-term central venous catheter

    DEFF Research Database (Denmark)

    Møller, Tom; Adamsen, Lis

    2010-01-01

    A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients.......A significant decrease in catheter-related infections was demonstrated in our earlier randomized controlled trial of central venous catheter (CVC) care in hematologic patients....

  9. Patency of Femoral Tunneled Hemodialysis Catheters and Factors Predictive of Patency Failure

    Energy Technology Data Exchange (ETDEWEB)

    Burton, Kirsteen R. [University Health Network, University of Toronto, Department of Medical Imaging, Division of Vascular and Interventional Radiology (Canada); Guo, Lancia L. Q. [University of Calgary, Department of Radiology (Canada); Tan, Kong T.; Simons, Martin E.; Sniderman, Kenneth W.; Kachura, John R.; Beecroft, John R.; Rajan, Dheeraj K., E-mail: dheeraj.rajan@uhn.on.ca [University Health Network, University of Toronto, Department of Medical Imaging, Division of Vascular and Interventional Radiology (Canada)

    2012-12-15

    Purpose: To determine the patency rates of and factors associated with increased risk of patency failure in patients with femoral vein tunneled hemodialysis catheters. Methods: All femoral tunneled catheter insertions from 1996 to 2006 were reviewed, during which time 123 catheters were inserted. Of these, 66 were exchanges. Patients with femoral catheter failure versus those with femoral catheter patency were compared. Confounding factors, such as demographic and procedural factors, were incorporated and assessed using univariate and multivariable Cox proportional hazards regression analyses. Results: Mean catheter primary patency failure time was 96.3 days (SE 17.9 days). Primary patency at 30, 60, 90, and 180 days was 53.8%, 45.4%, 32.1%, and 27.1% respectively. Crude rates of risk of catheter failure did not suggest a benefit for patients receiving catheters introduced from one side versus the other, but more cephalad location of catheter tip was associated with improved patency. Multivariate analysis showed that patients whose catheters were on the left side (p = 0.009), were of increasing age at the time of insertion (p = 0.002) and that those who had diabetes (p = 0.001) were at significantly greater risk of catheter failure. The catheter infection rate was 1.4/1000 catheter days. Conclusion: Patients who were of a more advanced age and had diabetes were at greater risk of femoral catheter failure, whereas those who received femoral catheters from the right side were less at risk of catheter failure.

  10. A neural framework for organization and flexible utilization of episodic memory in cumulatively learning baby humanoids.

    Science.gov (United States)

    Mohan, Vishwanathan; Sandini, Giulio; Morasso, Pietro

    2014-12-01

    Cumulatively developing robots offer a unique opportunity to reenact the constant interplay between neural mechanisms related to learning, memory, prospection, and abstraction from the perspective of an integrated system that acts, learns, remembers, reasons, and makes mistakes. Situated within such interplay lie some of the computationally elusive and fundamental aspects of cognitive behavior: the ability to recall and flexibly exploit diverse experiences of one's past in the context of the present to realize goals, simulate the future, and keep learning further. This article is an adventurous exploration in this direction using a simple engaging scenario of how the humanoid iCub learns to construct the tallest possible stack given an arbitrary set of objects to play with. The learning takes place cumulatively, with the robot interacting with different objects (some previously experienced, some novel) in an open-ended fashion. Since the solution itself depends on what objects are available in the "now," multiple episodes of past experiences have to be remembered and creatively integrated in the context of the present to be successful. Starting from zero, where the robot knows nothing, we explore the computational basis of organization episodic memory in a cumulatively learning humanoid and address (1) how relevant past experiences can be reconstructed based on the present context, (2) how multiple stored episodic memories compete to survive in the neural space and not be forgotten, (3) how remembered past experiences can be combined with explorative actions to learn something new, and (4) how multiple remembered experiences can be recombined to generate novel behaviors (without exploration). Through the resulting behaviors of the robot as it builds, breaks, learns, and remembers, we emphasize that mechanisms of episodic memory are fundamental design features necessary to enable the survival of autonomous robots in a real world where neither everything can be known

  11. Some Characterization Results on Dynamic Cumulative Residual Tsallis Entropy

    Directory of Open Access Journals (Sweden)

    Madan Mohan Sati

    2015-01-01

    Full Text Available We propose a generalized cumulative residual information measure based on Tsallis entropy and its dynamic version. We study the characterizations of the proposed information measure and define new classes of life distributions based on this measure. Some applications are provided in relation to weighted and equilibrium probability models. Finally the empirical cumulative Tsallis entropy is proposed to estimate the new information measure.

  12. Steps and pips in the history of the cumulative recorder.

    OpenAIRE

    Lattal, Kennon A.

    2004-01-01

    From its inception in the 1930s until very recent times, the cumulative recorder was the most widely used measurement instrument in the experimental analysis of behavior. It was an essential instrument in the discovery and analysis of schedules of reinforcement, providing the first real-time analysis of operant response rates and patterns. This review traces the evolution of the cumulative recorder from Skinner's early modified kymographs through various models developed by Skinner and his co...

  13. Ion beam sputter-etched ventricular catheter for hydrocephalus shunt

    Science.gov (United States)

    Banks, B. A. (Inventor)

    1983-01-01

    A cerebrospinal fluid shunt in the form of a ventricular catheter for controlling the condition of hydrocephalus by relieving the excessive cerebrospinal fluid pressure is described. A method for fabrication of the catheter and shunting the cerebral fluid from the cerebral ventricles to other areas of the body is also considered. Shunt flow failure occurs if the ventricle collapse due to improper valve function causing overdrainage. The ventricular catheter comprises a multiplicity of inlet microtubules. Each microtubule has both a large openings at its inlet end and a multiplicity of microscopic openings along its lateral surfaces.

  14. Childhood Cumulative Risk Exposure and Adult Amygdala Volume and Function.

    Science.gov (United States)

    Evans, Gary W; Swain, James E; King, Anthony P; Wang, Xin; Javanbakht, Arash; Ho, S Shaun; Angstadt, Michael; Phan, K Luan; Xie, Hong; Liberzon, Israel

    2016-06-01

    Considerable work indicates that early cumulative risk exposure is aversive to human development, but very little research has examined the neurological underpinnings of these robust findings. This study investigates amygdala volume and reactivity to facial stimuli among adults (mean 23.7 years of age, n = 54) as a function of cumulative risk exposure during childhood (9 and 13 years of age). In addition, we test to determine whether expected cumulative risk elevations in amygdala volume would mediate functional reactivity of the amygdala during socioemotional processing. Risks included substandard housing quality, noise, crowding, family turmoil, child separation from family, and violence. Total and left hemisphere adult amygdala volumes were positively related to cumulative risk exposure during childhood. The links between childhood cumulative risk exposure and elevated amygdala responses to emotionally neutral facial stimuli in adulthood were mediated by the corresponding amygdala volumes. Cumulative risk exposure in later adolescence (17 years of age), however, was unrelated to subsequent adult amygdala volume or function. Physical and socioemotional risk exposures early in life appear to alter amygdala development, rendering adults more reactive to ambiguous stimuli such as neutral faces. These stress-related differences in childhood amygdala development might contribute to the well-documented psychological distress as a function of early risk exposure.

  15. The impact of sodium citrate on dialysis catheter function and frequency of catheter-related bacteriemia and haemorrhage

    Directory of Open Access Journals (Sweden)

    Maciej Szymczak

    2009-10-01

    Full Text Available Vascular access is one of the most important problems of hemodialysis therapy. It is known that an arteriovenous fi sutla provides the best vascular access, but its creation is not always possible. Other solutions, such as the insertion of a central venous catheter, are then required. Adequate protection of such catheters by interdialytic fi ll with locking solution affects the frequency of hemodialysis-related complications. The most widespread catheter locking solution is heparin. Sodium citrate is being used more frequent recently. Available data indicate that hemorrhage is 11.9 times more frequent if the catheter locking solution is 5000 IU/ml heparin than if 4�0sodium citrate or 1000 IU/ml heparin is used. Other data indicate that the frequency of infection is statistically decreased when 30�0sodium citrate is used to fi ll the catheter instead of 5000 IU/ml heparin. Analogous data on 46.7�0sodium citrate are not consistent. It seems that the use of 4�0sodium citrate instead of 5000 IU/ml heparin does not decrease the frequency of infections. Numerous studies indicate that sodium citrate at various concentrations exerts a positive infl lence on catheter function. However, not all data are in accord. The spill of sodium citrate from the catheter to the systemic circulation is connected with a risk of adverse events. It may be dangerous if the citrate concentration is 46.7�20However, adequate fi lling of the catheter should prezent such events. Available data indicate that fi lling of the catheter with a solution of citrate of a concentration of no more than 30�0should be safe. Data on 46.7�0citrate are not conclusive, so precautions should be taken.

  16. Do pulmonary artery catheters alter outcome in trauma patients?

    Science.gov (United States)

    Kirton, O C; Civetta, J M

    1997-08-01

    To review the literature addressing the use of the pulmonary artery catheter (PAC) in victims of blunt and penetrating trauma and examine the available evidence that supports or refutes the claim that PAC use alters outcome in this patient population. Furthermore, to determine what additional research should be done in this area. All pertinent English language articles dealing with pulmonary artery catheterization in trauma patients were retrieved from 1979 through 1996. Clinical studies were considered if PACs were used to establish a cardiopulmonary diagnosis, optimize or achieve endpoints of oxygen transport and utilization indices, or guide and/or determine response to therapy. Emphasis was placed on prospective, randomized, controlled trials. However, descriptive case series and retrospectively-analyzed, uncontrolled reviews comprise the majority of available literature. From these selective studies, information was obtained regarding patient demographics, therapeutic endpoints, and achieved outcome. Insufficient evidence exists to support a true survival benefit. However, recommendations for indications can be proposed where a reduction in morbidity or improvement in functional outcome is suggested. Hemodynamic data obtained from the PAC appear to be beneficial for the following indications: a) to ascertain the status of underlying cardiovascular performance and/or the need for improvement; b) to direct therapy when noninvasive monitoring may be inadequate, misleading, or the endpoints of resuscitation difficult to define; c) to assess response to resuscitation; d) to potentially decrease secondary injury when severe closed-head or acute spinal cord injuries are components of multisystem trauma; e) to augment clinical decision-making when major trauma is complicated by severe adult respiratory distress syndrome, progressive oliguria/anuria, myocardial ischemia, congestive heart failure, or major thermal injury; and f) to establish futility of care.

  17. Catheter ablation of organized atrial arrhythmias in orthotopic heart transplantation.

    Science.gov (United States)

    Mouhoub, Yamina; Laredo, Mikael; Varnous, Shaida; Leprince, Pascal; Waintraub, Xavier; Gandjbakhch, Estelle; Hébert, Jean-Louis; Frank, Robert; Maupain, Carole; Pavie, Alain; Hidden-Lucet, Françoise; Duthoit, Guillaume

    2017-07-21

    Organized atrial arrhythmias (OAAs) are common after orthotopic heart transplantation (OHT). Some controversies remain about their clinical presentation, relationship with atrial anastomosis and electrophysiologic features. The objectives of this retrospective study were to determine the mechanisms of OAAs after OHT and describe the outcomes of radiofrequency catheter ablation (RFCA). Thirty consecutive transplanted patients (mean age 48 ± 17 years, 86.6% male) underwent 3-dimensional electroanatomic mapping and RFCA of their OAA from 2004 to 2012 at our center. Twenty-two patients had biatrial anastomosis and 8 had bicaval anastomosis. Macro-reentry was the arrhythmia mechanism for 96% of patients. The electrophysiologic diagnoses were: cavotricuspid isthmus (CTI)-dependent atrial flutter (AFL) in 93% of patients (n = 28); perimitral AFL in 3% (n = 1); and focal atrial tachycardia (FAT) in 3% (n = 1). In 5 patients with biatrial anastomosis, a right FAT was inducible. Primary RFCA success was obtained in 93% of patients. Mean follow-up time was 39 ± 26.8 months. Electrical repermeation between recipient and donor atria, present in 20% of patients (n = 6), did not account for any of the OAAs observed. Survival without OAA relapse at 12, 24 and 60 months was 93%, 89% and 79%, respectively. CTI-dependent AFL accounted for most instances of OAA after OHT, regardless of anastomosis type. Time from transplantation to OAA was shorter with bicaval than with biatrial anastomosis. RFCA was safe and provided good long-term results. Copyright © 2017 International Society for the Heart and Lung Transplantation. Published by Elsevier Inc. All rights reserved.

  18. Radiographic signs of non-venous placement of intended central venous catheters in children

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, Erin C. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Taylor, George A. [Boston Children' s Hospital, Department of Radiology, Boston, MA (United States); Harvard Medical School, Department of Radiology, Boston, MA (United States)

    2016-02-15

    Central venous catheters (CVCs) are commonly used in children, and inadvertent arterial or extravascular cannulation is rare but has potentially serious complications. To identify the radiographic signs of arterial placement of CVCs. We retrospectively reviewed seven cases of arterially malpositioned CVCs on chest radiograph. These cases were identified through departmental quality-assurance mechanisms and external consultation. Comparison of arterial cases was made with 127 age-matched chest radiographs with CVCs in normal, expected venous location. On each anteroposterior (AP) radiograph we measured the distance of the catheter tip from the right lateral border of the thoracic spine, and the angle of the vertical portion of the catheter relative to the midline. On each lateral radiograph we measured the angle of the vertical portion of each catheter relative to the anterior border of the thoracic spine. When bilateral subclavian catheters were present, the catheter tips were described as crossed, overlapping or uncrossed. On AP radiographs, arterially placed CVCs were more curved to the left, with catheter tip positions located farther to the left of midline than normal venous CVCs. When bilateral, properly placed venous catheters were present, all catheters crossed at the level of the superior vena cava (SVC). When one of the bilateral catheters was in arterial position, neither of the catheters crossed or the inter-catheter crossover distance was exaggerated. On lateral radiographs, there was a marked anterior angulation of the vertical portion of the catheter (mean angle 37 ± 15 standard deviation [SD] in arterial catheters versus 5.9 ± 8.3 SD in normally placed venous catheters). Useful radiographic signs suggestive of unintentional arterial misplacement of vascular catheters include leftward curvature of the vertical portion of the catheter, left-side catheter tip position, lack of catheter crossover on the frontal radiograph, as well as exaggerated

  19. Effect of Arm Positioning on Entrapment of Infraclavicular Nerve Block Catheter

    Science.gov (United States)

    Reddy, Rahul; Kendall, Mark C.; Nader, Antoun; Weeks, Jessica J.

    2017-01-01

    Continuous brachial plexus nerve block catheters are commonly inserted for postoperative analgesia after upper extremity surgery. Modifications of the insertion technique have been described to improve the safety of placing an infraclavicular brachial plexus catheter. Rarely, these catheters may become damaged or entrapped, complicating their removal. We describe a case of infraclavicular brachial plexus catheter entrapment related to differences in arm positioning during catheter placement and removal. Written authorization to obtain, use, and disclose information and images was obtained from the patient.

  20. Temperature mediated moose survival in Northeastern Minnesota

    Science.gov (United States)

    Lenarz, M.S.; Nelson, M.E.; Schrage, M.W.; Edwards, A.J.

    2009-01-01

    The earth is in the midst of a pronounced warming trend and temperatures in Minnesota, USA, as elsewhere, are projected to increase. Northern Minnesota represents the southern edge to the circumpolar distribution of moose (Alces alces), a species intolerant of heat. Moose increase their metabolic rate to regulate their core body temperature as temperatures rise. We hypothesized that moose survival rates would be a function of the frequency and magnitude that ambient temperatures exceeded the upper critical temperature of moose. We compared annual and seasonal moose survival in northeastern Minnesota between 2002 and 2008 with a temperature metric. We found that models based on January temperatures above the critical threshold were inversely correlated with subsequent survival and explained >78 of variability in spring, fall, and annual survival. Models based on late-spring temperatures also explained a high proportion of survival during the subsequent fall. A model based on warm-season temperatures was important in explaining survival during the subsequent winter. Our analyses suggest that temperatures may have a cumulative influence on survival. We expect that continuation or acceleration of current climate trends will result in decreased survival, a decrease in moose density, and ultimately, a retreat of moose northward from their current distribution.

  1. Advancements in Catheter-Directed Ultrasound-Accelerated Thrombolysis

    NARCIS (Netherlands)

    Doomernik, Denise E.; Schrijver, A. Marjolein; Zeebregts, Clark J.; de Vries, Jean-Paul P. M.; Reijnen, Michel M. P. J.

    2011-01-01

    Purpose: To review all available literature on catheter-directed ultrasound-accelerated thrombolysis for peripheral artery occlusions, stroke, deep venous thrombosis, and pulmonary embolism. Methods: A systematic literature search was performed, using MEDLINE, EMBASE and Cochrane databases. A total

  2. Advancements in catheter-directed ultrasound-accelerated thrombolysis.

    NARCIS (Netherlands)

    Doomernik, D.E.; Schrijver, A.M.; Zeebregts, C.J.A.; Vries, J.P. de; Reijnen, M.M.P.J.

    2011-01-01

    PURPOSE: To review all available literature on catheter-directed ultrasound-accelerated thrombolysis for peripheral artery occlusions, stroke, deep venous thrombosis, and pulmonary embolism. METHODS: A systematic literature search was performed, using MEDLINE, EMBASE and Cochrane databases. A total

  3. Three Dimensional Modeling of an MRI Actuated Steerable Catheter System.

    Science.gov (United States)

    Liu, Taoming; Cavuşoğlu, M Cenk

    2014-01-01

    This paper presents the three dimensional kinematic modeling of a novel steerable robotic ablation catheter system. The catheter, embedded with a set of current-carrying micro-coils, is actuated by the magnetic forces generated by the magnetic field of the MRI scanner. This paper develops a 3D model of the MRI actuated steerable catheter system by using finite differences approach. For each finite segment, a quasi-static torque-deflection equilibrium equation is calculated using beam theory. By using the deflection displacements and torsion angles, the kinematic modeling of the catheter system is derived. The proposed models are evaluated by comparing the simulation results of the proposed model with the experimental results of a proof-of-concept prototype.

  4. Urinary catheter related nosocomial infections in paediatric intensive care unit.

    Directory of Open Access Journals (Sweden)

    Tullu M

    1998-04-01

    Full Text Available The present prospective study was carried out in the Paediatric Intensive Care Unit (PICU of a tertiary care teaching hospital in Mumbai. The objective was to determine the incidence, risk factors, mortality and organisms responsible for urinary catheter related infections (UCRI. Colonization and/or bacteriuria was labelled as urinary catheter related infection (UCRI. Forty-four patients with 51 urinary catheters were studied. Incidence of UCRI was 47.06%. Age, female sex and immunocompromised status did not increase the risk of UCRI. Duration of catheter in-situ and duration of stay in the PICU were associated with higher risk of UCRI. The mortality was not increased by UCRI. Commonest organism isolated in UCRI was E. coli, which had maximum susceptibility to nitrofurantoin and amikacin.

  5. Pericardial tamponade and death from Hickman catheter perforation.

    Science.gov (United States)

    Murray, B H; Cohle, S D; Davison, P

    1996-12-01

    In February 1995, a 56-year-old female was taken to the operating room for routine placement of a Hickman catheter. Her internist planned palliative chemotherapy for metastatic breast cancer. Using the Seldinger technique, the right subclavian vein was entered and a Hickman catheter was placed. Shortly after extubation and arrival in the postoperative recovery unit, the patient had respiratory and cardiac arrest. Resuscitative efforts, including chest tube placement and pericardiocentesis, were unsuccessful. Autopsy findings included perforation of the superior vena cava, with extension of the catheter in the pericardial sac and associated effusion. Despite the low reported incidence of perforation during placement of central venous catheters, we recommend confirmation of placement by fluoroscopy and instillation of radiopaque dye because of the high mortality associated with this complication.

  6. Automatic rupture of unused intraport catheter. Case report.

    Science.gov (United States)

    Pappas, Paris; Dalianis, Nikolaos; Filippou, Dimitrios K; Condiis, Nicolas; Rizos, Spiros; Skandalakis, Panagiotis

    2007-01-01

    Totally Implantable Central Venous Access Devices (Intraports) are commonly used in cancer patients to administer chemotherapy or parenteral nutrition. These devices are placed by Seldinger technique. We report an unusual case of intraport catheter rupture before the use of the device. The ruptured part of the catheter migrated into the left pulmonary vein via right ventricle. The ruptured part was removed by means of interventional radiology before causing any problems to the patient. All the reported ruptures of port catheters refer to port devices that had been used to administer chemotherapy, fluids, or parenteral nutrition. The unique feature of this case is that the catheter had not been used at all. It is of great interest also the removal of the broken part from the pulmonary vein.

  7. Analysis of damping characteristics of arterial catheter blood ...

    African Journals Online (AJOL)

    part, by the damping characteristics of the arterial catheter blood pressure ... A cross-sectional, observational study of arterial line measurements in a large general ICU. ... and perfusion pressure, whilst preventing excessively high pressures.

  8. Thermal and hydrodynamic modelling of active catheters for interventional radiology.

    Science.gov (United States)

    Marchandise, Emilie; Flaud, Patrice; Royon, Laurent; Blanc, Raphaël; Szewczyk, Jérome

    2011-07-01

    Interventional radiologists desire to improve their operating tools such as catheters. Active catheters in which the tip is moved using shape memory alloy actuators activated using the Joule effect present a promising approach for easier navigation in the small vessels. However, the increase in temperature caused by this Joule effect must be controlled in order to prevent damage to blood cells and tissues. This paper is devoted to the simulation and experimental validation of a fluid-thermal model of an active catheter prototype. Comparisons between computer-predicted and experimentally measured temperatures are presented for both experiments in air and water at 37°C. Good agreement between the computational and experimental results is found, demonstrating the validity of the developed computer model. These comparisons enable us to highlight some important issues in the modelling process and to determine the optimal current for the activation of the catheter.

  9. Review of advanced catheter technologies in radiation oncology brachytherapy procedures.

    Science.gov (United States)

    Zhou, Jun; Zamdborg, Leonid; Sebastian, Evelyn

    2015-01-01

    The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented.

  10. Dialysis Catheters and Their Common Complications: An Update

    Directory of Open Access Journals (Sweden)

    Satyaki Banerjee

    2009-01-01

    Full Text Available Tunneled dialysis catheters (TDCs are associated with the highest rate of complications, morbidity, and mortality when compared to arteriovenous fistulas or grafts, and this relates to higher costs in their management. Over time, catheters are prone to higher rates of infection, thrombosis, and central venous stenosis, and, thereby, catheter dysfunction. Lower blood flow rates are a consequence of the dysfuncion. Despite efforts to reduce incident and prevalent rates of catheter use for dialysis by the National Kidney Foundation and Fistula First Initiative, they remain a common modality of hemodialysis. The management of common TDC-related complications is discussed, in addition to ways to reduce and prevent morbidity associated with their use.

  11. Safety of latex urinary catheters for the short time drainage

    Directory of Open Access Journals (Sweden)

    Mehrdad Hosseinpour

    2014-01-01

    Conclusion: It seems that urinary tract catheterization with latex catheters is a safe, feasible, and in-expensive procedure for short-term post-operative course in hypospadias surgery in patients without latex hypersensitivity.

  12. Anatomical Consideration in Catheter Ablation of Idiopathic Ventricular Arrhythmias.

    Science.gov (United States)

    Yamada, Takumi; Kay, G Neal

    2016-01-01

    Idiopathic ventricular arrhythmias (VAs) are ventricular tachycardias (VTs) or premature ventricular contractions (PVCs) with a mechanism that is not related to myocardial scar. The sites of successful catheter ablation of idiopathic VA origins have been progressively elucidated and include both the endocardium and, less commonly, the epicardium. Idiopathic VAs usually originate from specific anatomical structures such as the ventricular outflow tracts, aortic root, atrioventricular (AV) annuli, papillary muscles, Purkinje network and so on, and exhibit characteristic electrocardiograms based on their anatomical background. Catheter ablation of idiopathic VAs is usually safe and highly successful, but can sometimes be challenging because of the anatomical obstacles such as the coronary arteries, epicardial fat pads, intramural and epicardial origins, AV conduction system and so on. Therefore, understanding the relevant anatomy is important to achieve a safe and successful catheter ablation of idiopathic VAs. This review describes the anatomical consideration in the catheter ablation of idiopathic VAs.

  13. Dosimetric equivalence of nonstandard HDR brachytherapy catheter patterns

    Energy Technology Data Exchange (ETDEWEB)

    Cunha, J. A. M.; Hsu, I-C.; Pouliot, J. [University of California, San Francisco, California 94115 (United States)

    2009-01-15

    Purpose: To determine whether alternative high dose rate prostate brachytherapy catheter patterns can result in similar or improved dose distributions while providing better access and reducing trauma. Materials and Methods: Standard prostate cancer high dose rate brachytherapy uses a regular grid of parallel needle positions to guide the catheter insertion. This geometry does not easily allow the physician to avoid piercing the critical structures near the penile bulb nor does it provide position flexibility in the case of pubic arch interference. This study used CT datasets with 3 mm slice spacing from ten previously treated patients and digitized new catheters following three hypothetical catheter patterns: conical, bi-conical, and fireworks. The conical patterns were used to accommodate a robotic delivery using a single entry point. The bi-conical and fireworks patterns were specifically designed to avoid the critical structures near the penile bulb. For each catheter distribution, a plan was optimized with the inverse planning algorithm, IPSA, and compared with the plan used for treatment. Irrelevant of catheter geometry, a plan must fulfill the RTOG-0321 dose criteria for target dose coverage (V{sub 100}{sup Prostate}>90%) and organ-at-risk dose sparing (V{sub 75}{sup Bladder}<1 cc, V{sub 75}{sup Rectum}<1 cc, V{sub 125}{sup Urethra}<<1 cc). Results: The three nonstandard catheter patterns used 16 nonparallel, straight divergent catheters, with entry points in the perineum. Thirty plans from ten patients with prostate sizes ranging from 26 to 89 cc were optimized. All nonstandard patterns fulfilled the RTOG criteria when the clinical plan did. In some cases, the dose distribution was improved by better sparing the organs-at-risk. Conclusion: Alternative catheter patterns can provide the physician with additional ways to treat patients previously considered unsuited for brachytherapy treatment (pubic arch interference) and facilitate robotic guidance of

  14. Asystole during pulmonary artery catheter insertion under general anesthesia

    Directory of Open Access Journals (Sweden)

    Swapna Chaudhuri

    2012-01-01

    Full Text Available In spite of ongoing debate for the past 40 years, pulmonary artery catheters remain in use for invasive hemodynamic monitoring and management of critically ill patients. We describe a case of a sudden onset of asystolic cardiac arrest during the placement of a pulmonary artery catheter, while under general anesthesia. A brief review of the literature highlighting arrhythmic complications associated with pulmonary artery catheterization is also presented.

  15. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    OpenAIRE

    Zhou J.; Zamdborg L; Sebastian E

    2015-01-01

    Jun Zhou,1,2 Leonid Zamdborg,1 Evelyn Sebastian1 1Department of Radiation Oncology, Beaumont Health System, 2Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA Abstract: The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy ...

  16. Magnetic and robotic navigation for catheter ablation: "joystick ablation".

    Science.gov (United States)

    Ernst, Sabine

    2008-10-01

    Catheter ablation has become the treatment of choice to cure various arrhythmias in the last decades. The newest advancement of this general concept is made on the navigation ability using remote-controlled ablation catheters. This review summarizes the concept of the two currently available systems, followed by a critical review of the published clinical reports for each system, respectively. Despite the limited amount of data, an attempt to compare the two systems is made.

  17. Clinical Practice Guidelines for Vascular Catheter Infections Treatment.

    Directory of Open Access Journals (Sweden)

    Belkys Rodríguez Llerena

    2009-03-01

    Full Text Available Clinical Practice Guidelines for Vascular Catheter Infections Treatment. It has been defined as the presence of local or systemic signs without other obvious infection site, plus the microbiologic evidence involving the catheter. This document includes a review and update of concepts, main clinical aspects, and treatment and stresses the importance of prophylactic treatment. It includes assessment guidelines focused on the most important aspects to be accomplished.

  18. Misplaced central venous catheters: applied anatomy and practical management.

    Science.gov (United States)

    Gibson, F; Bodenham, A

    2013-03-01

    Large numbers of central venous catheters (CVCs) are placed each year and misplacement occurs frequently. This review outlines the normal and abnormal anatomy of the central veins in relation to the placement of CVCs. An understanding of normal and variant anatomy enables identification of congenital and acquired abnormalities. Embryological variations such as a persistent left-sided superior vena cava are often diagnosed incidentally only after placement of a CVC, which is seen to take an abnormal course on X-ray. Acquired abnormalities such as stenosis or thrombosis of the central veins can be problematic and can present as a failure to pass a guidewire or catheter or complications after such attempts. Catheters can also be misplaced outside veins in a patient with otherwise normal anatomy with potentially disastrous consequences. We discuss the possible management options for these patients including the various imaging techniques used to verify correct or incorrect catheter placement and the limitations of each. If the course of a misplaced catheter can be correctly identified as not lying within a vulnerable structure then it can be safely removed. If the misplaced catheter is lying within or traversing large and incompressible arteries or veins, it should not be removed before consideration of what is likely to happen when it is removed. Advice and further imaging should be sought, typically in conjunction with interventional radiology or vascular surgery. With regard to misplaced CVCs, in the short term, a useful aide memoir is: 'if in doubt, don't take it out'.

  19. Placement peripherally inserted central catheters (PICC): the upper arm approach

    Energy Technology Data Exchange (ETDEWEB)

    Choo, In Wook; Choo, Sung Wook; Choi, Dong Il; Yoon, Jung Hwan; Hwang, Jae Woong; Lim, Jae Hoon [Samsung Medical Center, Seoul (Korea, Republic of); Andrews, James C. [Mayo Clinic, Lansing (United States); Williams, David M.; Cho, Kyung J. [University of Michigan Hospital, Lansing (United States)

    1995-10-15

    To evaluate a recently developed technique to place a medium-duration (weeks to months) central venous access. Within three-year period, 635 patients were referred to interventional radiology suite for placement of peripherally inserted central catheter (PICC). Contrast medium was injected into the peripheral intravenous line and a puncture was made into the opacified vein near the junction of the middle and upper thirds of the upper arm, either the brachial or basilic vein under fluoroscopic guidance. A 5.5-French peel-away sheath was inserted into the vein and a 5-French silicone catheter was introduced with its distal tip to the junction of the right atrium and superior vena cava. Catheter placement was successful in all patients unless there was a central venous obstruction. Catheters were maintained from 2 days to 5 months with a mean of 3 weeks. Complications included infection requiring removal of the PICC in 16 patients (2.5%), acute thrombosis of the subclavian vein in 3 (0.5%). Occluded catheters in 4 patients were easily cleared with urokinase in place. The PICC system is an excellent option for medium-duration central venous access. Patients were able to carry on normal activities with the catheters in place.

  20. Review of advanced catheter technologies in radiation oncology brachytherapy procedures

    Directory of Open Access Journals (Sweden)

    Zhou J

    2015-07-01

    Full Text Available Jun Zhou,1,2 Leonid Zamdborg,1 Evelyn Sebastian1 1Department of Radiation Oncology, Beaumont Health System, 2Oakland University William Beaumont School of Medicine, Royal Oak, MI, USA Abstract: The development of new catheter and applicator technologies in recent years has significantly improved treatment accuracy, efficiency, and outcomes in brachytherapy. In this paper, we review these advances, focusing on the performance of catheter imaging and reconstruction techniques in brachytherapy procedures using magnetic resonance images and electromagnetic tracking. The accuracy of catheter reconstruction, imaging artifacts, and other notable properties of plastic and titanium applicators in gynecologic treatments are reviewed. The accuracy, noise performance, and limitations of electromagnetic tracking for catheter reconstruction are discussed. Several newly developed applicators for accelerated partial breast irradiation and gynecologic treatments are also reviewed. New hypofractionated high dose rate treatment schemes in prostate cancer and accelerated partial breast irradiation are presented. Keywords: catheter technologies, catheter reconstruction, electromagnetic tracking, hypofractionated high dose rate treatment, accelerated partial breast irradiation

  1. [Anesthetic consideration in patients undergoing catheter ablation for atrial fibrillation].

    Science.gov (United States)

    Oda, Toshiyuki; Takahama, Yutaka

    2012-11-01

    This chapter describes anesthetic consideration in patients undergoing catheter ablation for atrial fibrillation (AF) based on electrophysiologic or pharmacological aspects. In the 2011 guidelines of the Japanese Circulation Society for non-pharmacotherapy of cardiac arrhythmias, catheter ablation is recommended as Class I therapeutic modality for the patients with drug-refractory paroxysmal AF. Catheter ablation of AF is an invasive and long-lasting procedure necessitating sedation during treatment. However, in the most of the patients, sedation or anesthesia is possibly performed by cardiologists using propofol, midazolam or dexmedetomidine. Deep sedation accompanies a high risk of ventilatory or circulatory derangement. Furthermore, life-threatening complications, such as cerebral infarction or cardiac tamponade, can occur during ablation. Patients with AF are increasing in number as a trend in the aging society, resulting in an increase in catheter ablation in high risk patients. To accomplish safe anesthetic management of the patients for catheter ablations, anesthesiologists are required to have fundamental knowledge and skill in the performance of the catheter ablation.

  2. Technical considerations in the use of external condom catheter systems.

    Science.gov (United States)

    deHoll, J D; Williams, L A; Steers, W D; Rodeheaver, G T; Clark, M M; Edlich, R F

    1992-01-01

    Since the advent of rehabilitation engineering new advances have been made that have revolutionized condom catheter drainage systems (CCDS). An innovative CCDS has been designed that ensures unobstructed urine flow. Its condom catheter has several unique design features. It has a double row of convolutions near the catheter tip that prevent kinking and twisting so that the pathway remains open. The condom catheter features a unique inner flap that fits snugly on the glans to prevent backflow of urine on the shaft. This condom catheter is connected to a vented leg bag that eliminates the development of a partial vacuum in the connecting tube. This vacuum can create siphoning, which in turn interferes with urine flow into the leg bag. In addition, a new rechargeable battery-operated clipper has been developed that makes nick-free hair removal from the genitals exceptionally easy. This atraumatic hair removal eliminates the pubic hair that becomes trapped under the condom catheter. The clinical impact of these new advances in CCDS requires further investigation.

  3. National survey of catheter ablation for atrial fibrillation: The Japanese catheter ablation registry of atrial fibrillation (J-CARAF

    Directory of Open Access Journals (Sweden)

    Koichi Inoue

    2013-08-01

    Conclusions: Ipsilateral encircling PVI, using 3D mapping and irrigated-tip catheters, is the standard AF ablation method in Japan. However, adjunctive ablations were performed frequently, even in patients with paroxysmal AF.

  4. Cumulative risks of foster care placement for Danish children.

    Science.gov (United States)

    Fallesen, Peter; Emanuel, Natalia; Wildeman, Christopher

    2014-01-01

    Although recent research suggests that the cumulative risk of foster care placement is far higher for American children than originally suspected, little is known about the cumulative risk of foster care placement in other countries, which makes it difficult to gauge the degree to which factor foster care placement is salient in other contexts. In this article, we provide companion estimates to those provided in recent work on the US by using Danish registry data and synthetic cohort life tables to show how high and unequally distributed the cumulative risk of foster care placement is for Danish children. Results suggest that at the beginning of the study period (in 1998) the cumulative risk of foster care placement for Danish children was roughly in line with the risk for American children. Yet, by the end of the study period (2010), the risk had declined to half the risk for American children. Our results also show some variations by parental ethnicity and sex, but these differences are small. Indeed, they appear quite muted relative to racial/ethnic differences in these risks in the United States. Last, though cumulative risks are similar between Danish and American children (especially at the beginning of the study period), the age-specific risk profiles are markedly different, with higher risks for older Danish children than for older American children.

  5. Latino Mothers' Cumulative Food Insecurity Exposure and Child Body Composition.

    Science.gov (United States)

    Hernandez, Daphne C

    2016-01-01

    To document whether an intergenerational transmission of food insecurity is occurring by assessing low-income foreign-born Latino mothers' experiences with food insecurity as none, once (either childhood or adulthood) or twice (during both childhood and adulthood). Also the association between maternal cumulative food insecurity and children's body composition was examined. Maternal self-reported surveys on retrospective measures of food insecurity during childhood, current measures of food insecurity, and demographics were collected from Houston-area community centers (N = 96). Children's body mass index (BMI) and waist circumference (WC) were directly assessed. Covariate-adjusted logistic regression models analyzed the association between cumulative food insecurity experiences and children's body composition. Fifty-eight percent of mothers experienced food insecurity both as a child and as an adult and 31% of the mothers experienced food insecurity either as a child or adult. Maternal cumulative exposure to food insecurity was unrelated to BMI but was negatively related to elevated WC. Although an intergenerational transmission of food insecurity does exist, maternal cumulative exposure to food insecurity does not impact children's body composition negatively in the short term. Studying the long-term effects of cumulative food insecurity exposure can provide information for the development and timing of obesity interventions.

  6. USING CUMULATIVE NUMBER DENSITIES TO COMPARE GALAXIES ACROSS COSMIC TIME

    Energy Technology Data Exchange (ETDEWEB)

    Behroozi, Peter S.; Wechsler, Risa H. [Kavli Institute for Particle Astrophysics and Cosmology, SLAC National Accelerator Laboratory, Stanford, CA 94305 (United States); Marchesini, Danilo [Department of Physics and Astronomy, Tufts University, Medford, MA 02155 (United States); Muzzin, Adam [Leiden Observatory, Leiden University, P.O. Box 9513, 2300 RA Leiden (Netherlands); Papovich, Casey [Department of Physics and Astronomy, Texas A and M University, College Station, TX 77843 (United States); Stefanon, Mauro [Physics and Astronomy Department, University of Missouri, Columbia, MO 65211 (United States)

    2013-11-01

    Comparing galaxies across redshifts at fixed cumulative number density is a popular way to estimate the evolution of specific galaxy populations. This method ignores scatter in mass accretion histories and galaxy-galaxy mergers, which can lead to errors when comparing galaxies over large redshift ranges (Δz > 1). We use abundance matching in the ΛCDM paradigm to estimate the median change in cumulative number density with redshift and provide a simple fit (+0.16 dex per unit Δz) for progenitors of z = 0 galaxies. We find that galaxy descendants do not evolve in the same way as galaxy progenitors, largely due to scatter in mass accretion histories. We also provide estimates for the 1σ range of cumulative number densities corresponding to galaxy progenitors and descendants. Finally, we discuss some limits on cumulative number density comparisons, which arise due to difficulties measuring physical quantities (e.g., stellar mass) consistently across redshifts. A public tool to calculate cumulative number density evolution for galaxies, as well as approximate halo masses, is available online.

  7. Maintenance hemodialysis patients have high cumulative radiation exposure.

    LENUS (Irish Health Repository)

    Kinsella, Sinead M

    2010-10-01

    Hemodialysis is associated with an increased risk of neoplasms which may result, at least in part, from exposure to ionizing radiation associated with frequent radiographic procedures. In order to estimate the average radiation exposure of those on hemodialysis, we conducted a retrospective study of 100 patients in a university-based dialysis unit followed for a median of 3.4 years. The number and type of radiological procedures were obtained from a central radiology database, and the cumulative effective radiation dose was calculated using standardized, procedure-specific radiation levels. The median annual radiation dose was 6.9 millisieverts (mSv) per patient-year. However, 14 patients had an annual cumulative effective radiation dose over 20 mSv, the upper averaged annual limit for occupational exposure. The median total cumulative effective radiation dose per patient over the study period was 21.7 mSv, in which 13 patients had a total cumulative effective radiation dose over 75 mSv, a value reported to be associated with a 7% increased risk of cancer-related mortality. Two-thirds of the total cumulative effective radiation dose was due to CT scanning. The average radiation exposure was significantly associated with the cause of end-stage renal disease, history of ischemic heart disease, transplant waitlist status, number of in-patient hospital days over follow-up, and death during the study period. These results highlight the substantial exposure to ionizing radiation in hemodialysis patients.

  8. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exi...

  9. Potential In Vivo UVC Disinfection of Catheter Lumens: Estimation of the Doses Received by the Blood Flow Outside the Catheter Tip Hole

    DEFF Research Database (Denmark)

    Bak, Jimmy; Jørgensen, Thomas Martini; Helfmann, Jurgen;

    2011-01-01

    We have demonstrated that it is possible to launch UVC LED light into bacterial contaminated polymer tubes/catheters and disinfect the intraluminal space of these tubes. This can be achieved by UVC treatment of the catheters on a regular basis. Catheters are in the distal end equipped with an exi...

  10. The Mass Media of Entertainment and Human Survival.

    Science.gov (United States)

    Gorney, Roderic; Steele, Gary

    Urgently needed for human survival is a means of influencing large numbers of people to put into rapid action measures which could neutralize such menances as pollution, overpopulation, and violence. Though the cumulative effect of the mass media is not fully established, media entertainment may be the most influential institution in our society.…

  11. The Mass Media of Entertainment and Human Survival.

    Science.gov (United States)

    Gorney, Roderic; Steele, Gary

    Urgently needed for human survival is a means of influencing large numbers of people to put into rapid action measures which could neutralize such menances as pollution, overpopulation, and violence. Though the cumulative effect of the mass media is not fully established, media entertainment may be the most influential institution in our society.…

  12. Pulsatile flow in ventricular catheters for hydrocephalus

    Science.gov (United States)

    Giménez, Á.; Galarza, M.; Thomale, U.; Schuhmann, M. U.; Valero, J.; Amigó, J. M.

    2017-05-01

    The obstruction of ventricular catheters (VCs) is a major problem in the standard treatment of hydrocephalus, the flow pattern of the cerebrospinal fluid (CSF) being one important factor thereof. As a first approach to this problem, some of the authors studied previously the CSF flow through VCs under time-independent boundary conditions by means of computational fluid dynamics in three-dimensional models. This allowed us to derive a few basic principles which led to designs with improved flow patterns regarding the obstruction problem. However, the flow of the CSF has actually a pulsatile nature because of the heart beating and blood flow. To address this fact, here we extend our previous computational study to models with oscillatory boundary conditions. The new results will be compared with the results for constant flows and discussed. It turns out that the corrections due to the pulsatility of the CSF are quantitatively small, which reinforces our previous findings and conclusions. This article is part of the themed issue `Mathematical methods in medicine: neuroscience, cardiology and pathology'.

  13. Fast integrated intravascular photoacoustic/ultrasound catheter

    Science.gov (United States)

    Choi, Changhoon; Cho, Seunghee; Kim, Taehoon; Park, Sungjo; Park, Hyoeun; Kim, Jinmoo; Lee, Seunghoon; Kang, Yeonsu; Jang, Kiyuk; Kim, Chulhong

    2016-03-01

    In cardiology, a vulnerable plaque is considered to be a key subject because it is strongly related to atherosclerosis and acute myocardial infarction. Because conventional intravascular imaging devices exhibit several limitations with regard to vulnerable plaque detection, the need for an effective lipid imaging modality has been continuously suggested. Photoacoustic (PA) imaging is a medical imaging technique with a high level of ultrasound (US) resolution and strong optical contrast. In this study, we successfully developed an integrated intravascular photoacoustic/ultrasound (IV-PAUS) imaging system with a catheter diameter of 1.2 mm for lipid-rich atherosclerosis imaging. An Nd:YAG pulsed laser with an excitation wavelength of 1064 nm was utilized. IV-PAUS offers 5-mm depth penetration and axial and lateral PA imaging resolutions of 94 μm and 203 μm, respectively, as determined by imaging a 6-μm carbon fiber. We initially obtained 3-dimensional (3D) co-registered PA/US images of metal stents. Subsequently, we successfully obtained 3D coregistered PA/US ex vivo images using an iliac artery from a rabbit atherosclerosis model. Accordingly, lipid-rich plaques were sufficiently differentiated from normal tissue in the ex vivo experiment. We validated these findings histologically to confirm the lipid content.

  14. Cumulative Trauma Among Mayas Living in Southeast Florida.

    Science.gov (United States)

    Millender, Eugenia I; Lowe, John

    2016-01-04

    Mayas, having experienced genocide, exile, and severe poverty, are at high risk for the consequences of cumulative trauma that continually resurfaces through current fear of an uncertain future. Little is known about the mental health and alcohol use status of this population. This correlational study explored t/he relationship of cumulative trauma as it relates to social determinants of health (years in the United States, education, health insurance status, marital status, and employment), psychological health (depression symptoms), and health behaviors (alcohol use) of 102 Guatemalan Mayas living in Southeast Florida. The results of this study indicated that, as specific social determinants of health and cumulative trauma increased, depression symptoms (particularly among women) and the risk for harmful alcohol use (particularly among men) increased. Identifying risk factors at an early stage before serious disease or problems are manifest provides room for early screening leading to early identification, early treatment, and better outcomes.

  15. Analysis of sensory ratings data with cumulative link models

    DEFF Research Database (Denmark)

    Christensen, Rune Haubo Bojesen; Brockhoff, Per B.

    2013-01-01

    Examples of categorical rating scales include discrete preference, liking and hedonic rating scales. Data obtained on these scales are often analyzed with normal linear regression methods or with omnibus Pearson chi2 tests. In this paper we propose to use cumulative link models that allow...... for regression methods similar to linear models while respecting the categorical nature of the observations. We describe how cumulative link models are related to the omnibus chi2 tests and how they can lead to more powerful tests in the non-replicated setting. For replicated categorical ratings data we present...... a quasi-likelihood approach and a mixed effects approach both being extensions of cumulative link models. We contrast population-average and subject-specific interpretations based on these models and discuss how different approaches lead to different tests. In replicated settings, naive tests that ignore...

  16. Cumulative pion production via successive collisions in nuclear medium

    CERN Document Server

    Motornenko, A

    2016-01-01

    Production of pions in proton-nucleus (p+A) reactions outside of a kinematical boundary of proton-nucleon collisions, the so-called cumulative effect, is studied. The kinematical restrictions on pions emitted in backward direction in the target rest frame are analyzed. It is shown that cumulative pion production requires a presence of massive baryonic resonances that are produced during successive collisions of projectile with nuclear nucleons. After each successive collision the mass of created resonance may increase and, simultaneously, its longitudinal velocity decreases. Simulations within Ultra relativistic Quantum Molecular Dynamics model reveals that successive collisions of baryonic resonances with nuclear nucleons plays the dominant role in cumulative pion production in p+A reactions.

  17. Solid-state electro-cumulation effect numerical simulation

    CERN Document Server

    Grishin, V G

    2001-01-01

    It is an attempt to simulate as really as possible a crystal's interatomic interaction under conditions of "Solid-state electro-cumulation (super-polarization) effect". Some theoretical and experimental reasons to believe that within solid substances an interparticles interaction could concentrate from the surface to a centre were given formerly. Now, numerical results show the conditions that could make the cumulation more effective. Another keywords: ion, current, solid, symmetry, cumulation, polarization, depolarization, ionic conductor,superionic conductor, ice, crystal, strain, V-center, V-centre, doped crystal, interstitial impurity, intrinsic color center, high pressure technology, Bridgman, anvil, experiment, crowdion, dielectric, proton, layer, defect, lattice, dynamics, electromigration, mobility, muon catalysis, concentration, doping, dopant, conductivity, pycnonuclear reaction, permittivity, dielectric constant, point defects, interstitials, polarizability, imperfection, defect centers, glass, epi...

  18. Association between diastolic blood pressure and cumulative work time

    Directory of Open Access Journals (Sweden)

    Ricardo Cordeiro

    1999-01-01

    Full Text Available Diastolic blood pressure was viewed as a generic indicator of aging, and its association with cumulative work time was studied after controlling for age as a potential confounding factor. The study was conducted among production line workers at a Brazilian tannery in July 1993. The association between diastolic blood pressure and cumulative work time was verified by fitting a second-order linear regression model, where diastolic blood pressure was a function of worker's age and cumulative work time. By fitting the model, one can predict that, in the beginning of working life at the tannery, on average each 1-year period is associated with an increase of about 1.5 mmHg in diastolic blood pressure. The fit obtained highlights one component directly associated with work as part of the rate of pressure increase in the study group. This component is twice as high as that directly associated with age.

  19. Baltic Sea biodiversity status vs. cumulative human pressures

    DEFF Research Database (Denmark)

    Andersen, Jesper H.; Halpern, Benjamin S.; Korpinen, Samuli

    2015-01-01

    Abstract Many studies have tried to explain spatial and temporal variations in biodiversity status of marine areas from a single-issue perspective, such as fishing pressure or coastal pollution, yet most continental seas experience a wide range of human pressures. Cumulative impact assessments have...... been developed to capture the consequences of multiple stressors for biodiversity, but the ability of these assessments to accurately predict biodiversity status has never been tested or ground-truthed. This relationship has similarly been assumed for the Baltic Sea, especially in areas with impaired...... status, but has also never been documented. Here we provide a first tentative indication that cumulative human impacts relate to ecosystem condition, i.e. biodiversity status, in the Baltic Sea. Thus, cumulative impact assessments offer a promising tool for informed marine spatial planning, designation...

  20. Session: What do we know about cumulative or population impacts

    Energy Technology Data Exchange (ETDEWEB)

    Kerlinger, Paul; Manville, Al; Kendall, Bill

    2004-09-01

    This session at the Wind Energy and Birds/Bats workshop consisted of a panel discussion followed by a discussion/question and answer period. The panelists were Paul Kerlinger, Curry and Kerlinger, LLC, Al Manville, U.S. Fish and Wildlife Service, and Bill Kendall, US Geological Service. The panel addressed the potential cumulative impacts of wind turbines on bird and bat populations over time. Panel members gave brief presentations that touched on what is currently known, what laws apply, and the usefulness of population modeling. Topics addressed included which sources of modeling should be included in cumulative impacts, comparison of impacts from different modes of energy generation, as well as what research is still needed regarding cumulative impacts of wind energy development on bird and bat populations.

  1. Cumulant dynamics in a finite population linkage equilibrium theory

    CERN Document Server

    Rattray, M; Rattray, Magnus; Shapiro, Jonathan L.

    1999-01-01

    The evolution of a finite population at linkage equilibrium is described in terms of the dynamics of phenotype distribution cumulants. This provides a powerful method for describing evolutionary transients and we elucidate the relationship between the cumulant dynamics and the diffusion approximation. A separation of time-scales between the first and higher cumulants for low mutation rates is demonstrated in the diffusion limit and provides a significant simplification of the dynamical system. However, the diffusion limit may not be appropriate for strong selection as the standard Fisher-Wright model of genetic drift can break down in this case. Two novel examples of this effect are considered: we shown that the dynamics may depend on the number of loci under strong directional selection and that environmental variance results in a reduced effective population size. We also consider a simple model of a changing environment which cannot be described by a diffusion equation and we derive the optimal mutation ra...

  2. Effect of correlation on cumulants in heavy-ion collisions

    CERN Document Server

    Mishra, D K; Netrakanti, P K

    2015-01-01

    We study the effects of correlation on cumulants and their ratios of net-proton multiplicity distribution which have been measured for central (0-5\\%) Au+Au collisions at Relativistic Heavy Ion Collider (RHIC). This effect has been studied assuming individual proton and anti-proton distributions as Poisson or Negative Binomial Distribution (NBD). In-spite of significantly correlated production due to baryon number, electric charge conservation and kinematical correlations of protons and anti-protons, the measured cumulants of net-proton distribution follow the independent production model. In the present work we demonstrate how the introduction of correlations will affect the cumulants and their ratios for the difference distributions. We have also demonstrated this study using the proton and anti-proton distributions obtained from HIJING event generator.

  3. A pilot study to assess adductor canal catheter tip migration in a cadaver model.

    Science.gov (United States)

    Leng, Jody C; Harrison, T Kyle; Miller, Brett; Howard, Steven K; Conroy, Myles; Udani, Ankeet; Shum, Cynthia; Mariano, Edward R

    2015-04-01

    An adductor canal catheter may facilitate early ambulation after total knee arthroplasty, but there is concern over preoperative placement since intraoperative migration of catheters may occur from surgical manipulation and result in ineffective analgesia. We hypothesized that catheter type and subcutaneous tunneling may influence tip migration for preoperatively inserted adductor canal catheters. In a male unembalmed human cadaver, 20 catheter insertion trials were divided randomly into one of four groups: flexible epidural catheter either tunneled or not tunneled; or rigid stimulating catheter either tunneled or not tunneled. Intraoperative patient manipulation was simulated by five range-of-motion exercises of the knee. Distance and length measurements were performed by a blinded regional anesthesiologist. Changes in catheter tip to nerve distance (p = 0.225) and length of catheter within the adductor canal (p = 0.467) were not different between the four groups. Two of five non-tunneled stimulating catheters (40 %) were dislodged compared to 0/5 in all other groups (p = 0.187). A cadaver model may be useful for assessing migration of regional anesthesia catheters; catheter type and subcutaneous tunneling may not affect migration of adductor canal catheters based on this preliminary study. However, future studies involving a larger sample size, actual patients, and other catheter types are warranted.

  4. System Dynamics and Modified Cumulant Neglect Closure Schemes

    DEFF Research Database (Denmark)

    Köylüoglu, H. Ugur; Nielsen, Søren R.K.

    Dealing with multipeaked problems, the goal of the paper is to improve the quality of the approximations for the expectations appearing in the differential equations written for the statistical moments of the state vector, guided by insight in the system dynamics. For systems with polynomial non......-linearities, modifications in the cumulant neglect closure scheme are suggested. The methodology is illustrated using the two wells oscillator. An error analysis is performed to compare the modified and ordinary cumulant neglect closure schemes applied at the second and fourth order levels with the exact results available....

  5. Baltic Sea biodiversity status vs. cumulative human pressures

    DEFF Research Database (Denmark)

    Andersen, Jesper H.; Halpern, Benjamin S.; Korpinen, Samuli

    2015-01-01

    been developed to capture the consequences of multiple stressors for biodiversity, but the ability of these assessments to accurately predict biodiversity status has never been tested or ground-truthed. This relationship has similarly been assumed for the Baltic Sea, especially in areas with impaired...... status, but has also never been documented. Here we provide a first tentative indication that cumulative human impacts relate to ecosystem condition, i.e. biodiversity status, in the Baltic Sea. Thus, cumulative impact assessments offer a promising tool for informed marine spatial planning, designation...

  6. Aspect of cumulative fatigue damage under multiaxial strain cycling.

    Science.gov (United States)

    Zamrik, S. Y.; Tang, P. Y.

    1972-01-01

    The concept of order of loading and its effect on cumulative fatigue damage under multiaxial strain cyclings was investigated. The effect is illustrated through nonlinear relationships between biaxial fatigue damage and cycle-ratio diagrams. Uniaxial theories such as Miner's method, the convergence method, and the double linear damage rule in its special and generalized form, were examined and extended to the biaxial case through the octahedral shear strain theory. The generalized double linear damage rule was found more applicable to biaxial cumulative fatigue damage.

  7. Cumulative Incidence of Cancer After Solid Organ Transplantation

    Science.gov (United States)

    Hall, Erin C.; Pfeiffer, Ruth M.; Segev, Dorry L.; Engels, Eric A.

    2014-01-01

    BACKGROUND Solid organ transplantation recipients have elevated cancer incidence. Estimates of absolute cancer risk after transplantation can inform prevention and screening. METHODS The Transplant Cancer Match Study links the US transplantation registry with 14 state/regional cancer registries. The authors used nonparametric competing risk methods to estimate the cumulative incidence of cancer after transplantation for 2 periods (1987–1999 and 2000–2008). For recipients from 2000 to 2008, the 5-year cumulative incidence, stratified by organ, sex, and age at transplantation, was estimated for 6 preventable or screen-detectable cancers. For comparison, the 5-year cumulative incidence was calculated for the same cancers in the general population at representative ages using Surveillance, Epidemiology, and End Results data. RESULTS Among 164,156 recipients, 8520 incident cancers were identified. The absolute cancer risk was slightly higher for recipients during the period from 2000 to 2008 than during the period from 1987 to 1999 (5-year cumulative incidence: 4.4% vs 4.2%; P =.006); this difference arose from the decreasing risk of competing events (5-year cumulative incidence of death, graft failure, or retransplantation: 26.6% vs 31.9%; P 50 years; range, 0.36%–2.22%). For recipients aged >50 years, the 5-year cumulative incidence was higher for colorectal cancer (range, 0.33%–1.94%) than for the general population at the recommended screening age (aged 50 years: range, 0.25%–0.33%). For recipients aged >50 years, the 5-year cumulative incidence was high for lung cancer among thoracic organ recipients (range, 1.16%–3.87%) and for kidney cancer among kidney recipients (range, 0.53%–0.84%). The 5-year cumulative incidence for prostate cancer and breast cancer was similar or lower in transplantation recipients than at the recommended ages of screening in the general population. CONCLUSIONS Subgroups of transplantation recipients have a high absolute risk

  8. A study of cumulative fatigue damage in AISI 4130 steel

    Science.gov (United States)

    Jeelani, S.; Musial, M.

    1986-01-01

    Experimental data were obtained using AISI 4130 steel under stress ratios of -1 and 0. A study of cumulative fatigue damage using Miner's and Kramer's equations for stress ratios of -1 and 0 for low-high, low-high-mixed, high-low, and high-low-mixed stress sequences has revealed that there is a close agreement between the theoretical and experimental values of fatigue damage and fatigue life. Kramer's equation predicts less conservative and more realistic cumulative fatigue damage than the popularly used Miner's rule does.

  9. Initial Clinical Experience: Symmetric-Tip Dialysis Catheter with Helical Flow Characteristics Improves Patient Outcomes.

    Science.gov (United States)

    Clark, Timothy W I; Redmond, Jonas W; Mantell, Mark P; Nadolski, Gregory J; Mondschein, Jeffrey I; Dowd, Michael F; Dagli, Mandeep S; Sudheendra, Deepak; Shlansky-Goldberg, Richard D; Cohen, Raphael D

    2015-10-01

    To report preliminary clinical experience with a new symmetric-tip dialysis catheter compared with a conventional split-tip catheter. Over a 5-month period, patients requiring a tunneled catheter for hemodialysis or undergoing exchange of a dysfunctional dialysis catheter at a tertiary academic medical center were retrospectively analyzed. Patients underwent placement of a VectorFlow or Ash Split Cath catheter at the discretion of the inserting interventional radiologist. Patient demographics, catheter patency, mean blood flow rate, and arterial and venous pressures were compared according to catheter type. Catheter failure was analyzed based on clinical and anatomic variables by using a multivariate Cox proportional-hazards model. A total of 33 VectorFlow and 46 Ash Split Cath catheters were placed. Patients in the VectorFlow group had significantly higher body mass index (P = .013) and Charlson Comorbidity Index (P = .049), as well as more non-internal jugular vein placements. At 120 days, 89% of VectorFlow catheters remained functional, compared with 45% of Ash Split Cath catheters (P = .046). The VectorFlow catheter was associated with 16% lower arterial pressures during dialysis (P = .009); mean blood flow rate was equivalent. On multivariate analysis, the risk of catheter failure was 13.3 times higher in the Ash Split Cath group compared with the VectorFlow group (P = .004). Left-sided catheters were also predictive of catheter failure (relative risk = 5.5; P = .02). The VectorFlow catheter was associated with a significant increase in intervention-free catheter patency compared with the Ash Split Cath catheter, with equivalent flow at lower arterial pressures during dialysis. Copyright © 2015 SIR. Published by Elsevier Inc. All rights reserved.

  10. Knowledge of nursing students about central venous catheters

    Directory of Open Access Journals (Sweden)

    Mlinar Suzana

    2012-01-01

    Full Text Available Background/Aim. Central venous catheters (CVC are at the crucial importance, particulary in the intensive therapy units. In order to handle a CVC safely, nursing students need to acquire theoretical and practical knowledge during the course of their studies. The aim of the study was to establish theoretical knowledge of nursing students about the procedures of nurses in placing and removing a central venous catheter (CVC, dressing the catheter entry point, the reasons for measuring central venous pressure (CVP, possible complications and risk factors for developing infections related to CVC. Methods. The questionnaire developed specifically for this cross-sectionl study was handed out to 87 full-time students and 57 part-time students. Results. The results show that all the surveyed nursing students know why chest radiography is carried out when inserting a catheter, have relatively good knowledge of CVC insertion points, procedures carried out in case of a suspected catheter sepsis and complications and risk factors for the development of infections related to CVC. However, the study show that the majority of students have insufficient knowledge of the procedures accompanying insertion of a catheter, signs that indicate correct functioning of CVC, frequency of flushing a catheter when it is not in use and the reasons for introducing an implanted CVC. Conclusion. Based on the results of the study it can be concluded that the second-year nursing students have insufficient knowledge of CVC. In order to correctly and safely handle a CVC, good theoretical knowledge and relevant practical experience are needed. The authors therefore believe that, in future, the classes should be organized in smaller groups with step-by-step demonstrations of individual procedures in handling a CVC, and the students encouraged to learn as actively as possible.

  11. Feasibility of Endovascular Radiation Therapy Using Holmium-166 Filled Balloon Catheter in a Swine Hemodialysis Fistula Model: Preliminary Results

    Energy Technology Data Exchange (ETDEWEB)

    Won, Jong Yun; Lee, Kwang Hun; Lee, Do Yun [Dept. of Radiology, Research Institute of Radiological Science, Yensei University College of Medicine, Seoul (Korea, Republic of); Kim, Myoung Soo [Dept. of Radiology, Yensei University College of Medicine, Seoul (Korea, Republic of); Kang, Byung Chul [Dept. of Radiology, Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of); Kim, Seung Jung [Dept. of Internal Medicine, EwhaWoman' s University School of Medicine, Seoul (Korea, Republic of)

    2011-08-15

    To describe how to make a swine hemodialysis fistula model and report our initial experience to test the feasibility of endovascular radiation therapy with Holmium-166 filled balloon catheters. The surgical formation of arterio-venous fistula (AVF) was performed by end-to-side anastomosis of the bilateral jugular vein and carotid artery of 6 pigs. After 4 weeks, angiograms were taken and endovascular radiation was delivered to the venous side of AVF with Holmium-166 filled balloon catheters. Pigs were sacrificed 4 weeks after the radiation and AVFs were harvested for histological examination. All animals survived without any morbidity during the experimental periods. The formation of fistula on the sides of necks was successful in 11 of the 12 pigs (92%). One AVF failed from the small jugular vein. On angiograms, 4 of the 11 AVFs showed total occlusion or significant stenosis and therefore, endovascular radiation could not be performed. Of 7 eligible AVFs, five underwent successful endovascular radiation and two AVFs did not undergo radiation for the control. Upon histologic analysis, one non-radiated AVF showed total occlusion and others showed intimal thickening from the neointimal hyperplasia. Formation of the swine carotid artery-jugular vein hemodialysis fistula model was successful. Endovascular radiation using a Holmium-166 filled balloon catheter was safe and feasible.

  12. Initial impedance decrease as an indicator of good catheter contact: insights from radiofrequency ablation with force sensing catheters.

    Science.gov (United States)

    Reichlin, Tobias; Knecht, Sven; Lane, Christopher; Kühne, Michael; Nof, Eyal; Chopra, Nagesh; Tadros, Thomas M; Reddy, Vivek Y; Schaer, Beat; John, Roy M; Osswald, Stefan; Stevenson, William G; Sticherling, Christian; Michaud, Gregory F

    2014-02-01

    Good catheter-tissue contact force (CF) is critical for transmural and durable lesion formation during radiofrequency (RF) ablation but is difficult to assess in clinical practice. Tissue heating during RF application results in an impedance decrease at the catheter tip. The purpose of this study was to correlate achieved CF and initial impedance decreases during atrial fibrillation (AF) ablation. We correlated achieved CF and initial impedance decreases in patients undergoing ablation for AF with two novel open-irrigated CF-sensing RF catheters (Biosense Webster SmartTouch, n = 647 RF applications; and Endosense TactiCath, n = 637 RF applications). We then compared those impedance decreases to 691 RF applications with a standard open-irrigated RF catheter (Biosense Webster ThermoCool). When RF applications with the CF-sensing catheters were analyzed according to an achieved average CF 20 g, the initial impedance decreases during ablation were larger with greater CF. Corresponding median values at 20 seconds were 5 Ω (interquartile range [IQR] 2-7), 8 Ω (4-11), 10 Ω (7-16), and 14 Ω (10-19) with the SmartTouch and n/a, 4 Ω (0-10), 8 Ω (5-12), and 13 Ω (8-18) with the TactiCath (P decrease was significantly greater in the CF-sensing group with median decreases of 10 Ω (6-14 Ω) vs 5 Ω (2-10 Ω) at 20 seconds (P decrease during RF applications in AF ablations is larger when greater catheter contact is achieved. Monitoring of the initial impedance decrease is a widely available indicator of catheter contact and may help to improve formation of durable ablation lesions. © 2013 Heart Rhythm Society Published by Heart Rhythm Society All rights reserved.

  13. An epidural catheter removal after recent percutaneous coronary intervention and coronary artery stenting: Epidural catheter and antiaggregation therapy

    Directory of Open Access Journals (Sweden)

    Joksić Nikola

    2016-01-01

    Full Text Available Introduction: Anticoagulation and antiplatelet therapy in the presence of the epidural catheter is still controversial. It is well known that dual antiplatelet therapy is indicated for 12 months after the placement of drug-eluting stents (DES. Removal of an epidural catheter during that period is related to an increased risk of stent occlusion in case of discontinuation of platelet function inhibitors or, on the other hand, increased risk of epidural hematoma associated with neurological deficit if suppressed platelet function is still present. Case Report: Here we present a case of a 63-year-old man who was admitted to Institute for Cardiovascular Diseases Dedinje for elective aortic surgery. Before the induction, an epidural catheter was inserted at the Th10-Th11 epidural space. Uneventful surgery was performed under the combined epidural and general anesthesia. On the 2nd postoperative day, the patient sustained a ST depression myocardial infarction treated with percutaneous coronary intervention with DES placement, while epidural catheter was still in place. Dual antiplatelet therapy with 600mg of clopidogrel, 100 mg of acetilsalicylic acid (ASA and low molecular weight heparin (LMWH were started during the procedure. The next day, clopidogrel (75 mg and ASA (100 mg were continued as well as LMWH. The decision to remove the epidural catheter was made on the 9th postoperative day, after platelet aggregation assays were performed. Six hours after catheter removal the patient again received clopidogrel, ASA and LMWH. There were no signs of epidural hematoma. Conclusion: This case shows that point-of-care testing with platelet aggregation assays may be useful in increasing the margin of safety for epidural catheter removal during dual antiplatelet therapy.

  14. Hunter-gatherer inter-band interaction rates: implications for cumulative culture.

    Directory of Open Access Journals (Sweden)

    Kim R Hill

    Full Text Available Our species exhibits spectacular success due to cumulative culture. While cognitive evolution of social learning mechanisms may be partially responsible for adaptive human culture, features of early human social structure may also play a role by increasing the number potential models from which to learn innovations. We present interview data on interactions between same-sex adult dyads of Ache and Hadza hunter-gatherers living in multiple distinct residential bands (20 Ache bands; 42 Hadza bands; 1201 dyads throughout a tribal home range. Results show high probabilities (5%-29% per year of cultural and cooperative interactions between randomly chosen adults. Multiple regression suggests that ritual relationships increase interaction rates more than kinship, and that affinal kin interact more often than dyads with no relationship. These may be important features of human sociality. Finally, yearly interaction rates along with survival data allow us to estimate expected lifetime partners for a variety of social activities, and compare those to chimpanzees. Hadza and Ache men are estimated to observe over 300 men making tools in a lifetime, whereas male chimpanzees interact with only about 20 other males in a lifetime. High intergroup interaction rates in ancestral humans may have promoted the evolution of cumulative culture.

  15. Hunter-gatherer inter-band interaction rates: implications for cumulative culture.

    Science.gov (United States)

    Hill, Kim R; Wood, Brian M; Baggio, Jacopo; Hurtado, A Magdalena; Boyd, Robert T

    2014-01-01

    Our species exhibits spectacular success due to cumulative culture. While cognitive evolution of social learning mechanisms may be partially responsible for adaptive human culture, features of early human social structure may also play a role by increasing the number potential models from which to learn innovations. We present interview data on interactions between same-sex adult dyads of Ache and Hadza hunter-gatherers living in multiple distinct residential bands (20 Ache bands; 42 Hadza bands; 1201 dyads) throughout a tribal home range. Results show high probabilities (5%-29% per year) of cultural and cooperative interactions between randomly chosen adults. Multiple regression suggests that ritual relationships increase interaction rates more than kinship, and that affinal kin interact more often than dyads with no relationship. These may be important features of human sociality. Finally, yearly interaction rates along with survival data allow us to estimate expected lifetime partners for a variety of social activities, and compare those to chimpanzees. Hadza and Ache men are estimated to observe over 300 men making tools in a lifetime, whereas male chimpanzees interact with only about 20 other males in a lifetime. High intergroup interaction rates in ancestral humans may have promoted the evolution of cumulative culture.

  16. NURSING CARE IN PATIENTS NEONATES WITH PERIPHERALLY INSERTED CENTRAL CATHETER

    Directory of Open Access Journals (Sweden)

    Anacilda Oliveira Vieira

    2013-12-01

    Full Text Available Introduction: The PICC (peripherally inserted central catheter is a long flexible catheter which is inserted through a peripheral vein, progresses through a needle introducer until the final portion of the vena cava, acquiring characteristics of a central catheter. Objective: To point out the main theoretical and scientific ideas that demonstrate the reliability, competence and ability of nurses to perform the PICC. Methodology: Systematic review of articles, which were found by searching the database scientific journals and bibliographies area. Results: The success of integration depends on the patient assessment and choice of venous access where the catheter will be positioned, and its tip should be in the middle third of the superior vena cava, or the middle third of the inferior vena cava. In neonates, which are used more frequently, proper positioning of the catheter is through nursing care in making the dressing, and the first 24 hours it should be compressive. Ideally, the PICC remains in the vein for periods longer than seven days or until the end of treatment, thus decreasing invasive procedures. Conclusion: According to the Federal Board of Nursing (COFEN, it is lawful for the insertion of PICC nurses, provided it has undergone professional training.

  17. Catheter-related infection in gastrointestinal fistula patients

    Institute of Scientific and Technical Information of China (English)

    Ge-Fei Wang; Jian-An Ren; Jun Jiang; Cao-Gan Fan; Xin-Bo Wang; Jie-Shou Li

    2004-01-01

    AIM: To study the incidence, bacterial spectrum and drug sensitivity of catheter-related infection (CRI) in gastrointestinal fistula patients.METHODS: A total of 216 patients with gastrointestinal fistulae during January 1998 to April 2001 were studied retrospectively. Two hundred and sixteen catheters of the 358 central venous catheters used in 216 gastrointestinal fistula patients were sent for microbiology analysis.RESULTS: Ninety-five bacteria were cultivated in 88catheters (24.6%). There were 54 Gram-negative bacteria (56.8%), 35 Gram-positive bacteria (36.8%), and 6 fungi (6.4%). During the treatment of CRI, 20 patients changed to use antibiotics or antifungal, and all patients were cured.The mean time of catheters used was 16.9±13.0 d.CONCLUSION: CRI is still the common complication during total parenteral nutrition (TPN) treatment in patients with gastrointestinal fistulae, and Gram-negative bacteria are the main pathogens, and bacterial translocation is considered the common reason for CRI.

  18. Assessment of the potential for catheter heating during MR imaging

    Science.gov (United States)

    Baek, Bryant; Saloner, David; Acevedo-Bolton, Gabriel; Higashida, Randall; Comstock, John; Martin, Alastair

    2008-03-01

    There is an increasing interest in using MR imaging as a means of guiding endovascular procedures due to MR's unparalleled soft tissue characterization capabilities and its ability to assess functional parameters such as blood flow and tissue perfusion. In order to evaluate the potential safety risk of catheter heating, we performed in vitro testing where we measured heat deposition in sample non-ferrous 5F catheters ranging in length from 80cm - 110cm within a gel phantom. To identify the conditions for maximum heat deposition adjacent to catheters, we measured (1) the effect of variable immersed lengths, (2) the effect of variable SAR, and (3) whether heating varied along the catheter shaft. Net temperature rise per scan and initial rate of temperature rise were determined for all configurations. The temperature recordings clearly and consistently demonstrated the correlations between MR scanning under the three variable conditions and heat deposition. Our overall maximum heating condition, which combined the maximum heating conditions of all three variables, was modest (<2°C/min), but well above the temperature response of the gel well away from the catheter. Reduced SAR acquisitions effectively limited these temperature rises, and RF exposure levels of 0.2W/kg produced little detectible temperature change over the 2 minute MR acquisitions studied here. A combination of SAR limits and imaging duty cycle restrictions appear to be sufficient to permit MR imaging in catheterized patients without concern for thermal injury.

  19. Port- a- Cath Catheter placement by general surgery residents

    Directory of Open Access Journals (Sweden)

    F. Schlottmann

    2015-04-01

    Full Text Available In recent years an increasing incidence and prevalence of oncological diseases is observed, with a consequent increase in chemotherapies. In order to avoid repeated venipuncture of patients and toxicity in small veins during different cycles of treatment, devices that provide a permanent central venous access are used. The aim of this study was to evaluate the success and safety of port a cath devices inserted by surgery residents. A consecutive case series of patients in whom Port-a-CathTM catheter was placed by residents of surgery in the period from March 2009 to January 2014 were included. A total of 358 Port-a-CathTM catheters were inserted. Average age 58.7 years (16-88. Females 53.1%. Chemotherapy treatment for solid neoplasias (74.8% and for hematological diseases (25.2%. SThe different venous accesses were: Subclavian (67.6%, Cephalic (27.4%, external jugular (3.3%, internal jugular (1.7%. The morbidity rate was 5.3%, twelve patients with catheter-associated infection requiring the removal of it, 3 venous thrombosis with subsequent replacement of the catheter and 4 patients required pleural drainage. Port-a-CathTM catheter placement by residents is a safe and effective procedure for the administration of chemotherapy

  20. Epidural fibrosis after permanent catheter insertion and infusion.

    Science.gov (United States)

    Aldrete, J A

    1995-11-01

    Forty-six permanent epidural catheters and life-port units were implanted in 43 patients with severe, recurrent low back pain who had been considered not to be candidates for surgical intervention and in whom other therapeutic modalities had failed. Eight cases developed epidural fibrosis (EF). For analgesia, patients received either infusions with preservative-free solutions of fentanyl and bupivacaine or daily boluses of morphine and bupivacaine. Catheters remained from 75 days to 433 days. Signs of EF appeared from 21 days to 320 days after implantation. Pain at injection or resistance to injection were initial manifestations of EF, followed by poor, and eventually, nil analgesic effect. The epidural catheters were made of either polyamide, silicone, or polyurethane. Epidurograms revealed encapsulation, narrowing, and loculation of epidural space with gradually reduced spread of the contrast material. The occurrence of EF limits the permanency of implanted epidural catheters. The infusate does not cause this complication, which appears to be a foreign body reaction due to the presence of the catheter in the epidural space.

  1. Hemodialysis Catheter Heat Transfer for Biofilm Prevention and Treatment.

    Science.gov (United States)

    Richardson, Ian P; Sturtevant, Rachael; Heung, Michael; Solomon, Michael J; Younger, John G; VanEpps, J Scott

    2016-01-01

    Central line-associated bloodstream infections (CLABSIs) are not easily treated, and many catheters (e.g., hemodialysis catheters) are not easily replaced. Biofilms (the source of infection) on catheter surfaces are notoriously difficult to eradicate. We have recently demonstrated that modest elevations of temperature lead to increased staphylococcal susceptibility to vancomycin and significantly soften the biofilm matrix. In this study, using a combination of microbiological, computational, and experimental studies, we demonstrate the efficacy, feasibility, and safety of using heat as an adjuvant treatment for infected hemodialysis catheters. Specifically, we show that treating with heat in the presence of antibiotics led to additive killing of Staphylococcus epidermidis with similar trends seen for Staphylococcus aureus and Klebsiella pneumoniae. The magnitude of temperature elevation required is relatively modest (45-50°C) and similar to that used as an adjuvant to traditional cancer therapy. Using a custom-designed benchtop model of a hemodialysis catheter, positioned with tip in the human vena cava as well as computational fluid dynamic simulations, we demonstrate that these temperature elevations are likely achievable in situ with minimal increased in overall blood temperature.

  2. Development of a balloon volume sensor for pulsating balloon catheters.

    Science.gov (United States)

    Nolan, Timothy D C; Hattler, Brack G; Federspiel, William J

    2004-01-01

    Helium pulsed balloons are integral components of several cardiovascular devices, including intraaortic balloon pumps (IABP) and a novel intravenous respiratory support catheter. Effective use of these devices clinically requires full inflation and deflation of the balloon, and improper operating conditions that lead to balloon under-inflation can potentially reduce respiratory or cardiac support provided to the patient. The goal of the present study was to extend basic spirographic techniques to develop a system to dynamically measure balloon volumes suitable for use in rapidly pulsating balloon catheters. The dynamic balloon volume sensor system (DBVSS) developed here used hot wire anemometry to measure helium flow in the drive line from console to catheter and integrated the flow to determine the volume delivered in each balloon pulsation. An important component of the DBVSS was an algorithm to automatically detect and adjust flow signals and measured balloon volumes in the presence of gas composition changes that arise from helium leaks occurring in these systems. The DBVSS was capable of measuring balloon volumes within 5-10% of actual balloon volumes over a broad range of operating conditions relevant to IABP and the respiratory support catheter. This includes variations in helium concentration from 70-100%, pulsation frequencies from 120-480 beats per minute, and simulated clinical conditions of reduced balloon filling caused by constricted vessels, increased driveline, or catheter resistance.

  3. Heparin Leakage in Central Venous Catheters by Hemodynamic Transport

    Science.gov (United States)

    Barbour, Michael; McGah, Patrick; Gow, Kenneth; Aliseda, Alberto

    2014-11-01

    Central venous catheters (CVCs), placed in the superior vena cava for hemodialysis, are routinely filled with heparin, an anticoagulant, while not in use to maintain patency and prevent thrombus formation at the catheter tip. However, the heparin-lock procedure places the patient at risk for systemic bleeding incidences, as heparin is known to leak into the blood stream. We propose that the driving mechanism behind heparin leakage is advective-diffusive transport due to the pulsatile blood flow surrounding the catheter tip. This novel hypothesis is based on Planar Laser Induced Fluorescence (PLIF) measurements of heparin transport from a CVC placed inside an in vitro pulsatile flow loop and validated with CFD simulations. The results show an initial, fast (catheter lumen, where concentration is still high, that is insufficient at replenishing the lost heparin at the tip. These results, which estimate leakage rates consistent with published in vivo data, predict that the concentration of heparin at the catheter tip is effectively zero for the majority of the interdialytic phase, rendering the heparin lock ineffective.

  4. Fantoni’s Tracheostomy using Catheter High Frequency Jet Ventilation

    Directory of Open Access Journals (Sweden)

    P. Török

    2012-01-01

    Full Text Available Background: It has been shown previously that conventional ventilation delivered through a long cuffed endotracheal tube is associated with a high flow-resistance and frequent perioperative complications. Aim: We attempted to supersede the conventional ventilation by high-frequency jet ventilation through a catheter (HFJV-C and assess safety of the procedure. Material and methods: Using a translaryngeal tracheostomy kit, we performed a translaryngeal (Fantoni tracheostomy (TLT. Subsequently, we introduced a special 2-way prototype ventilatory catheter into the trachea via the TLT under bronchoscopic control. Satisfactory HFJV-C ventilation through the catheter was achieved in 218 patients. Results: There were no significant adverse effects on vital signs observed in the cohort during the study. The pH, SpO2, PaO2, and PaCO2 did not change significantly following the HFJV-C. The intrinsic PEEPi measured in trachea did not exceed 4—5 cm H2O during its application, which was significantly less than during the classical ventilation via the endotracheal tube fluctuating between 12 and 17 cm H2O. No serious medical complications occurred. Conclusion: The HFJV during Fantoni’s tracheostomy using the catheter HFJV-C proved to be a safe and effective method of lung ventilation at the intensive care unit. Key words: Translaryngeal tracheostomy, HFJV via catheter.

  5. Hemodialysis catheter related rhodococcus bacteremia in immunocompetent host

    Directory of Open Access Journals (Sweden)

    Pranav Dalal

    2011-01-01

    Full Text Available Rhodococcus equi (R. equi is an uncommon cause of infection in immunocompetent individuals. We describe a case of R. equi bacteremia associated with hemodialysis (HD catheter in an immunocompetent patient. A 38-year-old female with end-stage renal disease (ESRD of uncertain etiology, on HD for the past 15 months who was previously healthy otherwise, was admitted with the complaints of intermittent fever, mild nausea and occasional vomiting for two weeks. Last HD was performed four days earlier through a tunneled right internal jugular permacath. Clinically the patient was afebrile and in no acute distress. She was hemodynamically stable with no peripheral stigmata of an endovascular infection. Physical examination was essentially normal. Initially, the patient was treated with intravenous vancomycin with each HD, retaining the catheter. However, due to persistently positive blood cultures, HD catheter had to be removed. The patient became afebrile and nausea and vomiting resolved. She improved clinically, and repeated surveillance blood cultures done after the removal of catheter were reported negative. Subsequently, a new HD catheter was inserted for her. Although R. equi is an uncommon cause of infection in immunocompetent individuals, it does occur with considerable mortality and morbidity, and a high index of clinical suspicion is required to recognize this infection in immunocompetent individuals.

  6. Rat indwelling urinary catheter model of Candida albicans biofilm infection.

    Science.gov (United States)

    Nett, Jeniel E; Brooks, Erin G; Cabezas-Olcoz, Jonathan; Sanchez, Hiram; Zarnowski, Robert; Marchillo, Karen; Andes, David R

    2014-12-01

    Indwelling urinary catheters are commonly used in the management of hospitalized patients. Candida can adhere to the device surface and propagate as a biofilm. These Candida biofilm communities differ from free-floating Candida, exhibiting high tolerance to antifungal therapy. The significance of catheter-associated candiduria is often unclear, and treatment may be problematic considering the biofilm drug-resistant phenotype. Here we describe a rodent model for the study of urinary catheter-associated Candida albicans biofilm infection that mimics this common process in patients. In the setting of a functioning, indwelling urinary catheter in a rat, Candida proliferated as a biofilm on the device surface. Characteristic biofilm architecture was observed, including adherent, filamentous cells embedded in an extracellular matrix. Similar to what occurs in human patients, animals with this infection developed candiduria and pyuria. Infection progressed to cystitis, and a biofilmlike covering was observed over the bladder surface. Furthermore, large numbers of C. albicans cells were dispersed into the urine from either the catheter or bladder wall biofilm over the infection period. We successfully utilized the model to test the efficacy of antifungals, analyze transcriptional patterns, and examine the phenotype of a genetic mutant. The model should be useful for future investigations involving the pathogenesis, diagnosis, therapy, prevention, and drug resistance of Candida biofilms in the urinary tract.

  7. Foley Catheter versus Vaginal Misoprostol for Labour Induction

    Directory of Open Access Journals (Sweden)

    Nasreen Noor

    2015-01-01

    Full Text Available Objectives. To compare the efficacy and safety of intravaginal misoprostol with transcervical Foley catheter for labour induction. Material and Methods. One hundred and four women with term gestation, with Bishop score < 4, and with various indications for labour induction were randomly divided into two groups. In Group I, 25 μg of misoprostol tablet was placed intravaginally, 4 hourly up to maximum 6 doses. In Group II, Foley catheter 16F was placed through the internal os of the cervix under aseptic condition and then inflated with 50 cc of sterile saline. Statistical analysis was done using SPSS software. Results. The induction to delivery interval was 14.03 ± 7.61 hours versus 18.40 ± 8.02 hours (p<0.01. The rate of vaginal delivery was 76.7% versus 56.8% in misoprostol and transcervical Foley catheter group, respectively. Uterine hyperstimulation was more common with misoprostol. Neonatal outcome was similar in both the groups. Conclusion. Intravaginal misoprostol is associated with a shorter induction to delivery interval as compared to Foley’s catheter and it increases the rate of vaginal delivery in cases of unripe cervix at term. Transcervical Foley catheter is associated with a lower incidence of uterine hyperstimulation during labour.

  8. A Parametric Cumulative Sum Statistic for Person Fit

    Science.gov (United States)

    Armstrong, Ronald D.; Shi, Min

    2009-01-01

    This article develops a new cumulative sum (CUSUM) statistic to detect aberrant item response behavior. Shifts in behavior are modeled with quadratic functions and a series of likelihood ratio tests are used to detect aberrancy. The new CUSUM statistic is compared against another CUSUM approach as well as traditional person-fit statistics. A…

  9. RECURSIVE CLASSIFICATION OF MQAM SIGNALS BASED ON HIGHER ORDER CUMULANTS

    Institute of Scientific and Technical Information of China (English)

    Chen Weidong; Yang Shaoquan

    2002-01-01

    A new feature based on higher order cumulants is proposed for classification of MQAM signals. Theoretical analysis justify that the new feature is invariant with respect to translation (shift), scale and rotation transform of signal constellations, and can suppress color or white additive Gaussian noise. Computer simulation shows that the proposed recursive orderreduction based classification algorithm can classify MQAM signals with any order.

  10. Hierarchical Bayesian parameter estimation for cumulative prospect theory

    NARCIS (Netherlands)

    Nilsson, H.; Rieskamp, J.; Wagenmakers, E.-J.

    2011-01-01

    Cumulative prospect theory (CPT Tversky & Kahneman, 1992) has provided one of the most influential accounts of how people make decisions under risk. CPT is a formal model with parameters that quantify psychological processes such as loss aversion, subjective values of gains and losses, and

  11. Cumulative psychosocial stress, coping resources, and preterm birth.

    Science.gov (United States)

    McDonald, Sheila W; Kingston, Dawn; Bayrampour, Hamideh; Dolan, Siobhan M; Tough, Suzanne C

    2014-12-01

    Preterm birth constitutes a significant international public health issue, with implications for child and family well-being. High levels of psychosocial stress and negative affect before and during pregnancy are contributing factors to shortened gestation and preterm birth. We developed a cumulative psychosocial stress variable and examined its association with early delivery controlling for known preterm birth risk factors and confounding environmental variables. We further examined this association among subgroups of women with different levels of coping resources. Utilizing the All Our Babies (AOB) study, an ongoing prospective pregnancy cohort study in Alberta, Canada (n = 3,021), multinomial logistic regression was adopted to examine the independent effect of cumulative psychosocial stress and preterm birth subgroups compared to term births. Stratified analyses according to categories of perceived social support and optimism were undertaken to examine differential effects among subgroups of women. Cumulative psychosocial stress was a statistically significant risk factor for late preterm birth (OR = 1.73; 95 % CI = 1.07, 2.81), but not for early preterm birth (OR = 2.44; 95 % CI = 0.95, 6.32), controlling for income, history of preterm birth, pregnancy complications, reproductive history, and smoking in pregnancy. Stratified analyses showed that cumulative psychosocial stress was a significant risk factor for preterm birth at psychosocial stress on the risk for early delivery.

  12. The proportional odds cumulative incidence model for competing risks

    DEFF Research Database (Denmark)

    Eriksson, Frank; Li, Jianing; Scheike, Thomas

    2015-01-01

    We suggest an estimator for the proportional odds cumulative incidence model for competing risks data. The key advantage of this model is that the regression parameters have the simple and useful odds ratio interpretation. The model has been considered by many authors, but it is rarely used in pr...

  13. Is learning in problem-based learning cumulative?

    NARCIS (Netherlands)

    E.H.J. Yew (Elaine); E. Chng (Esther); H.G. Schmidt (Henk)

    2011-01-01

    textabstractProblem-based learning (PBL) is generally organized in three phases, involving collaborative and self-directed learning processes. The hypothesis tested here is whether learning in the different phases of PBL is cumulative, with learning in each phase depending on that of the previous ph

  14. Cumulative assessment : Strategic choices to influence students' study effort

    NARCIS (Netherlands)

    Kerdijk, Wouter; Tio, Rene A.; Mulder, B. Florentine; Cohen-Schotanus, Janke

    2013-01-01

    Background: It has been asserted that assessment can and should be used to drive students' learning. In the current study, we present a cumulative assessment program in which test planning, repeated testing and compensation are combined in order to influence study effort. The program is aimed at hel

  15. Repeated mild injury causes cumulative damage to hippocampal cells

    NARCIS (Netherlands)

    E.J. Matser (Amy); C.I. de Zeeuw (Chris); J.T. Weber (John)

    2002-01-01

    textabstractAn interesting hypothesis in the study of neurotrauma is that repeated traumatic brain injury may result in cumulative damage to cells of the brain. However, post-injury sequelae are difficult to address at the cellular level in vivo. Therefore, it is necessary to compl

  16. The effects of cumulative practice on mathematics problem solving.

    Science.gov (United States)

    Mayfield, Kristin H; Chase, Philip N

    2002-01-01

    This study compared three different methods of teaching five basic algebra rules to college students. All methods used the same procedures to teach the rules and included four 50-question review sessions interspersed among the training of the individual rules. The differences among methods involved the kinds of practice provided during the four review sessions. Participants who received cumulative practice answered 50 questions covering a mix of the rules learned prior to each review session. Participants who received a simple review answered 50 questions on one previously trained rule. Participants who received extra practice answered 50 extra questions on the rule they had just learned. Tests administered after each review included new questions for applying each rule (application items) and problems that required novel combinations of the rules (problem-solving items). On the final test, the cumulative group outscored the other groups on application and problem-solving items. In addition, the cumulative group solved the problem-solving items significantly faster than the other groups. These results suggest that cumulative practice of component skills is an effective method of training problem solving.

  17. A Parametric Cumulative Sum Statistic for Person Fit

    Science.gov (United States)

    Armstrong, Ronald D.; Shi, Min

    2009-01-01

    This article develops a new cumulative sum (CUSUM) statistic to detect aberrant item response behavior. Shifts in behavior are modeled with quadratic functions and a series of likelihood ratio tests are used to detect aberrancy. The new CUSUM statistic is compared against another CUSUM approach as well as traditional person-fit statistics. A…

  18. Variable cultural acquisition costs constrain cumulative cultural evolution.

    Directory of Open Access Journals (Sweden)

    Alex Mesoudi

    Full Text Available One of the hallmarks of the human species is our capacity for cumulative culture, in which beneficial knowledge and technology is accumulated over successive generations. Yet previous analyses of cumulative cultural change have failed to consider the possibility that as cultural complexity accumulates, it becomes increasingly costly for each new generation to acquire from the previous generation. In principle this may result in an upper limit on the cultural complexity that can be accumulated, at which point accumulated knowledge is so costly and time-consuming to acquire that further innovation is not possible. In this paper I first review existing empirical analyses of the history of science and technology that support the possibility that cultural acquisition costs may constrain cumulative cultural evolution. I then present macroscopic and individual-based models of cumulative cultural evolution that explore the consequences of this assumption of variable cultural acquisition costs, showing that making acquisition costs vary with cultural complexity causes the latter to reach an upper limit above which no further innovation can occur. These models further explore the consequences of different cultural transmission rules (directly biased, indirectly biased and unbiased transmission, population size, and cultural innovations that themselves reduce innovation or acquisition costs.

  19. Cumulative index 1981-1985, Volumes 138-157.

    Science.gov (United States)

    1985-01-01

    This cumulative index also includes listings of all major papers from the American Journal of Neuroradiology, American Journal of Roentgenology, Clinics in Diagnostic Ultrasound, Journal of Computer Assisted Tomography, Journal of Ultrasound in Medicine, RadioGraphics, Radiologic Clinics of North America, Seminars in Nuclear Medicine, Seminars in Roentgenology, and Seminars in Ultrasound, CT and MR.

  20. Cumulative index 1981-1985, Volumes 138-157

    Energy Technology Data Exchange (ETDEWEB)

    1985-01-01

    This cumulative index also includes listings of all major papers from the American Journal of Neuroradiology, American Journal of Roentgenology, Clinics in Diagnostic Ultrasound, Journal of Computer Assisted Tomography, Journal of Ultrasound in Medicine, RadioGraphics, Radiologic Clinics of North America, Seminars in Nuclear Medicine, Seminars in Roentgenology, and Seminars in Ultrasound, CT and MR.

  1. Clinical Experience with a Hybrid Procedure Using the Adherent Clot Catheter for Salvage of Thrombosed Hemodialysis Access: A Comparison with the Standard Fogarty Balloon Catheter.

    Science.gov (United States)

    Yang, Yu Sung; Han, Kyu Dam; Choi, Eun Hye; Park, Young Sam; Seo, Yeon Ho; Kim, Cheol Seung

    2015-03-01

    This study aimed to compare the efficacy of two different catheters in hybrid surgery for salvage of thrombosed hemodialysis accesses. The hybrid salvage procedure (surgical thrombectomy followed by endovascular angioplasty) of the thrombosed hemodialysis access, was performed using adherent clot (AC) catheter in 140 cases and Fogarty balloon catheter in 68 cases. Procedure-related outcomes such as the clot removal status, clinical success, complications, and primary patency rates were analyzed retrospectively. The proportion of cases with good clot removal scores in the AC catheter and Fogarty balloon catheter groups was 77.9% and 91.2%, respectively (P=0.018). Clinical success was achieved in 90.7% of the cases in the AC catheter group and in 98.5% of the cases in the balloon catheter group (P=0.035). The mean patency rates of the two groups were 50.7% and 63.2% at 3 months, 40.7% and 47.1% at 6 months, and 17.9% and 19.1% at 12 months. The complication rates (12.1% and 5.9%) and primary patency rates between the two catheters were not statistically different (P=0.328). On the analysis of the patency rate on access type of autologous (P=0.169) and prothetic graft (P=0.423), there was no significant difference between the two catheter groups. In terms of clot removal and clinical success, the AC catheter did not demonstrate better outcomes than the Fogarty balloon catheter. However, primary patency was not related to the type of catheter. Adherent clot catheter can be a useful alternative to Fogarty balloon catheter for thrombosed hemodialysis access.

  2. Safety and functionality of transhepatic hemodialysis catheters in chronic hemodialysis patients.

    Science.gov (United States)

    Şanal, Bekir; Nas, Ömer Fatih; Doğan, Nurullah; Korkmaz, Mehmet; Hacıkurt, Kadir; Yıldız, Abdulmecid; Kan Aytaç, İrem İris; Hakyemez, Bahattin; Erdoğan, Cüneyt

    2016-01-01

    We aimed to investigate the safety and functionality of tunneled transhepatic hemodialysis catheters in chronic hemodialysis patients. Thirty-eight patients (20 women aged 56±10 years and 18 men aged 61±11 years) with transhepatic tunneled hemodialysis catheters were evaluated. The date of the first transhepatic catheterization, indications, procedure details, functional time periods of catheters, reasons for the removal or revision of catheters, catheter-related complications, and current conditions of patients were retrospectively analyzed. A total of 69 catheters were properly placed in all patients (100% technical success) under imaging guidance during the 91-month follow-up period. The functionality of 35 catheters could not be evaluated: five catheters were removed because of noncomplication related reasons (surgical fistulas were opened in two cases [2/35, 5.7%], transplantation was performed in three cases [3/35, 8.6%]), 18 patients died while their catheters were functional (18/35, 51.4%), and 12 catheters were still functional at the time of the study (12/35, 34.3%). The functionality of catheters was evaluated the remaining 34 catheters that necessitated revision because of complications. Furthermore, only half of the catheters were functional on day 136 when evaluated using Kaplan-Meier analysis. The four main complications were thrombosis (16/34, 47%; complication rate of 0.37 days in 100 catheters), infection (8/34, 23.5%; 0.18 days in 100 catheters), migration (8/34, 23.5%; 0.18 days in 100 catheters), and kinking (2/34, 6%; 0.04 days in 100 catheters). Transhepatic venous catheterization is a safe and functional alternative route in chronic hemodialysis patients without an accessible central venou route. The procedure can be performed with high technical success and low complication rates under imaging guidance.

  3. Outcome of tunneled infusion catheters inserted via the right internal jugular vein

    Energy Technology Data Exchange (ETDEWEB)

    Shin, Sung Wook; Do, Young Soo; Choo, Sung Wook; Yoo, Wi Kang; Choo, In Wook [Sungkyunkwan University School of Medicine, Seoul (Korea, Republic of); Kim, Jae Hyung [Sanggye Paik Hospital, Inje University, Seoul (Korea, Republic of)

    2003-03-01

    To assess the outcome of tunneled central venous catheter placement via the right internal jugular vein. Between June 2001 and May 2002, 670 consecutive Hickman catheters were placed in 654 patients via the right internal jugular vein. The procedural complications arising and follow-up data obtained from May to July 2002 were evaluated. The technical success rate for catheter placement was 99.9% (669/670). Procedural complications were limited to eight cases (1.2%), including three pneumothoraces, one early migration of the catheter, one clinically unimportant air embolism, one catheter injury, one catheter kinking and one primary malpositioning in the azygos vein. Catheter dwelling time ranged from 1 to 407 (mean 107.1) days. During the follow-up period, 416 catheter were removed for various reasons: treatment had ended (n=334), patients declined treatment or their drug regimen was changed (n=16), late complications arose (n=53), or other circumstances intervened (n=13). Late complications included 44 cases of catheter-related infection (6.6%), five of catheter migration (0.7%), two of catheter occlusion (0.3%), one of thrombophlebitis (0.15%), and one of catheter-related right atrial thrombosis (0.15%). Only one instance of symptomatic venous thrombosis or stenosis was noted, namely the one case of thrombophlebitis. Because the incidence of subsequent symptomatic venous thrombosis or stenosis is lower, the preferred route for tunneled central venous catheter placement is the right internal jugular vein.

  4. Placement of a Hemodialysis Catheter using the Dilated Right External Jugular Vein as a Primary Route

    Energy Technology Data Exchange (ETDEWEB)

    Park, Mi Hyun [Dankook University Hospital, Cheonan (Korea, Republic of); Shin, Byung Seok [Chungnam National University Hospital, Daejeon (Korea, Republic of)

    2010-08-15

    To evaluate the feasibility that a dilated right external jugular vein (EJV) could be a primary venous access site for large bore hemodialysis catheter placement. Between January 2008 and April 2009, a total of 173 hemodialysis catheters (14.5 F) were placed. Among them, we evaluated the clinical data of 42 patients who underwent placement through a dilated right EJV. We evaluated technical success, duration of catheterization in days, and the presence of complications. Technical success was achieved for 41 patients (98%). Catheter placement was unsuccessful in one patient due to narrowing of the EJV. The catheter dwell time ranged between 14 and 305 days (mean; 76 days, total catheter days: 3,111 days). A total of 26 hemodialysis catheters were removed due to complications (n=2) and termination of hemodialysis via the hemodialysis catheter (n=24). There was air embolization (n=1) and catheter kinking (n=3) during procedures and catheter related infections (n=2) during the follow-up period. The incidence of catheter related infection was 0.06 per 100 catheter days. No cases of catheter malfunction or symptomatic venous thrombosis were observed. We suggest that a dilated right EJV could be considered as a preferred primary route for hemodialysis catheter placement with easy access

  5. On the duration and intensity of cumulative advantage competitions and the struggle of the fittest

    CERN Document Server

    Jiang, Bo; Figueiredo, Daniel R; Ribeiro, Bruno; Towsley, Don

    2014-01-01

    At the heart of competition for resources lie two simple principles: "survival of the fittest", which reflects how intrinsic fitnesses of competing agents influence their ability to gather resources; and "cumulative advantage", which reflects how accumulated resources help gather even more resources. In this letter we show that competitions embodying just the essence of these two principlesexhibit a variety of surprising behaviors with respect to their duration, as measured by how long it takes for an indisputable winner to emerge, and intensity, as measured by how many times agents have equal amount of resources. We demonstrate that when the fitnesses of the agents are different, long-lasting competitions continue to occur in spite of a dramatic decrease in their intensity and the certainty that the fitter agent will win. We also unveil an unexpected phenomenon that we call "struggle of the fittest", where long-lasting competitions become more probable when one agent is slightly fitter than when agents are e...

  6. Linking turbine collision risks with population models to assess cumulative impacts of multiple wind farms on threatened birds

    Energy Technology Data Exchange (ETDEWEB)

    Smales, Ian; Muir, Stuart; Meredith, Charles; Baird, Robert

    2011-07-01

    Full text: Assessment of the effects on birds of wind turbine collisions has generally been focussed on the number of individuals that might be killed at a particular facility. However, this measure, of itself, may have little relevance to evaluating the potential or real effects on conservation status of threatened species. Determination of the overall effect any such mortality may have on the functioning of these populations will provide a better basis for decisions that have a strong foundation in ecology. For species with sufficient demographic information, we have developed and applied an approach combining collision risk modelling for all wind farms within the range of a threatened species with population modelling. This permits population-level evaluation of potential cumulative impacts of multiple wind farms. In Australia, regulatory authorities are increasingly interested in the cumulative risk to threatened species that may be posed by multiple wind energy facilities within a species. range. The approach outlined here has been applied in the pre-construction approval stage using collision risk modelling, and can be applied to operational facilities using data on actual mortalities. Cumulative modelling of risk posed by multiple wind farms requires different approaches for sedentary and migratory species. For sedentary species the cumulative effect will be the sum of the impact experienced by those parts of the population whose range intersects with wind farms. Cumulative impact is derived for migratory species by assessing the probability of birds surviving encounters with one wind farm after another on the migratory route and is thus the product of their survivorship rates for the relevant wind farms. The collision risk modelling used will be outlined along with the method in which it is integrated with a population model. Case studies for a crane (Brolga Grus rubicundus) and a parrot (orange- bellied parrot Neophema chrysogaster) species will be

  7. CUMULANTS OF STOCHASTIC RESPONSE FOR A CLASS OF SPECIAL NONHOLONOMIC SYSTEMS

    Institute of Scientific and Technical Information of China (English)

    SHANG MEI; ZHANG YI

    2001-01-01

    This paper studies the response cumulants for a kind of special nonholonomic systems under non-Gaussian, delta- correlated excitations. We present a new methodology for formulating the equations governing the evolution of the response cumulants of the stochastic dynamic systems. The response cumulant differential equations (CDEs) derived can be used to calculate the response cumulants for both linear and nonlinear systems. One example is given to illustrate how to use the CDEs for calculating response cumulants.

  8. A general framework for parametric survival analysis.

    Science.gov (United States)

    Crowther, Michael J; Lambert, Paul C

    2014-12-30

    Parametric survival models are being increasingly used as an alternative to the Cox model in biomedical research. Through direct modelling of the baseline hazard function, we can gain greater understanding of the risk profile of patients over time, obtaining absolute measures of risk. Commonly used parametric survival models, such as the Weibull, make restrictive assumptions of the baseline hazard function, such as monotonicity, which is often violated in clinical datasets. In this article, we extend the general framework of parametric survival models proposed by Crowther and Lambert (Journal of Statistical Software 53:12, 2013), to incorporate relative survival, and robust and cluster robust standard errors. We describe the general framework through three applications to clinical datasets, in particular, illustrating the use of restricted cubic splines, modelled on the log hazard scale, to provide a highly flexible survival modelling framework. Through the use of restricted cubic splines, we can derive the cumulative hazard function analytically beyond the boundary knots, resulting in a combined analytic/numerical approach, which substantially improves the estimation process compared with only using numerical integration. User-friendly Stata software is provided, which significantly extends parametric survival models available in standard software. Copyright © 2014 John Wiley & Sons, Ltd.

  9. An in vitro urinary tract catheter system to investigate biofilm development in catheter-associated urinary tract infections.

    Science.gov (United States)

    Dohnt, Katrin; Sauer, Marie; Müller, Maren; Atallah, Karin; Weidemann, Marina; Gronemeyer, Petra; Rasch, Detlev; Tielen, Petra; Krull, Rainer

    2011-12-01

    Biofilm development in urinary tract catheters is an often underestimated problem. However, this form of infection leads to high mortality rates and causes significant costs in health care. Therefore, it is important to analyze these biofilms and establish avoiding strategies. In this study a continuous flow-through system for the cultivation of biofilms under catheter-associated urinary tract infection conditions was established and validated. The in vitro urinary tract catheter system implies the composition of urine (artificial urine medium), the mean volume of urine of adults (1 mL min(-1)), the frequently used silicone catheter (foley silicon catheter) as well as the infection with uropathogenic microorganisms like Pseudomonas aeruginosa. Three clinical isolates from urine of catheterized patients were chosen due to their ability to form biofilms, their mobility and their cell surface hydrophobicity. As reference strain P. aeruginosa PA14 has been used. Characteristic parameters as biofilm thickness, specific biofilm growth rate and substrate consumption were observed. Biofilm thicknesses varied from 105±16 μm up to 246±67 μm for the different isolates. The specific biofilm growth rate could be determined with a non invasive optical biomass sensor. This sensor allows online monitoring of the biofilm growth in the progress of the cultivation.

  10. Bacterial Biofilms and Catheters: A Key to Understanding Bacterial Strategies in Catheter-Associated Urinary Tract Infection

    Directory of Open Access Journals (Sweden)

    J Curtis Nickel

    1992-01-01

    Full Text Available Despite major technological improvements in catheter drainage systems, the indwelling Foley catheter remains the most common cause of nosocomial infection in medical practice. By approaching this common complicated urinary tract infection from the perspective of the biofilm strategy bacteria appear to use to overcome obstacles to produce bacteriuria, one appreciates a new understanding of these infections. An adherent biofilm of bacteria in their secretory products ascends the luminal and external surface of the catheter and drainage system from a contaminated drainage spigot or urethral meatus into the bladder. If the intraluminal route of bacterial ascent is delayed by strict sterile closed drainage or addition of internal modifications to the system, the extraluminal or urethral route assumes greater importance in the development of bacteriuria, but takes significantly longer. Bacterial growth within these thick coherent biofilms confers a large measure of relative resistance to antibiotics even though the individual bacterium remains sensitive, thus accounting for the failure of antibiotic therapy. With disruption of the protective mucous layer of the bladder by mechanical irritation, the bacteria colonizing the catheter can adhere to the bladder’s mucosal surface and cause infection. An appreciation of the role of bacterial biofilms in these infections should suggest future directions for research that may ultimately reduce the risk of catheter-associated infection.

  11. The female experience of ISC with a silicone catheter.

    Science.gov (United States)

    Logan, Karen

    2017-01-26

    Intermittent self-catheterisation (ISC) is a safe and effective treatment in the management of neuropathic bladder, voiding dysfunction and urinary incontinence in women. ISC has been shown to improve quality of life when used appropriately. It provides freedom for individuals who require bladder drainage as they can choose where and when to catheterise to empty the bladder. ISC requires minimum equipment, is a more discreet solution than an indwelling catheter and is relatively easy to teach in one patient visit. There are a range of different ISC catheters available on prescription. Many have been designed specifically for women and patient choice regarding product selection is an important consideration. This article describes a UK patient-satisfaction survey evaluating the female patient's perspective of learning ISC using a silicone intermittent catheter called HydroSil Go(™) that is manufactured by C.R. Bard, Inc.

  12. Care of central venous catheters for total parenteral nutrition.

    Science.gov (United States)

    Collins, E; Lawson, L; Lau, M T; Barder, L; Weaver, F; Bayer, D; Schulz, M; Byrne, R; Hauser, M; Neubia, A; Dries, D

    1996-06-01

    This report summarizes data obtained via a mailed questionnaire from 129 Department of Veterans Affairs (VA) hospitals regarding current practices in the care of central venous catheters (CVCs) used for total parenteral nutrition (TPN). The size of VA hospitals' acute medical-surgical beds ranged from 14 to 1320 (median 168) beds. Over 6000 patients annually received CVCs for TPN. Hospitals reported using triple-lumen catheters most frequently as their CVC for TPN (80.3%). A povidone-iodine scrub was used to prepare the skin for CVC insertion by 72.6% of reporting hospitals. Sixty percent of hospitals used transparent polyurethane dressings. Care of CVCs varied among hospitals. Catheter-related infection and sepsis rates were within the national average, although < 50% of responding hospitals provided data on these outcomes. The results of this survey point to the need for a national standardized database relative to patients receiving TPN via a CVC.

  13. Dialysis Catheter Placement in Patients With Exhausted Access.

    Science.gov (United States)

    Rahman, Syed; Kuban, Joshua D

    2017-03-01

    Patients with end-stage renal disease undergo renal transplant, peritoneal dialysis, or intermittent hemodialysis for renal replacement therapy. For hemodialysis, native fistulas or grafts are preferred but hemodialysis catheters are often necessary. Per KDOQI, the right jugular vein is the preferred vessel of access for these catheters. However, in patients with long-standing end-stage renal disease vein thrombosis, stenosis and occlusion occurs. In these patients with end-stage vascular access, unconventional routes of placement of dialysis catheters are needed. These methods include placing them by means of sharp recanalization, via a translumbar route directly into the inferior vena cava, and via transhepatic and transrenal routes. These difficult, but potentially lifesaving methods of gaining vascular access are reviewed in this article. Copyright © 2017 Elsevier Inc. All rights reserved.

  14. A European perspective on intravascular catheter-related infections

    DEFF Research Database (Denmark)

    Bouza, E; San Juan, R; Muñoz, P;

    2004-01-01

    The laboratory workload, microbiological techniques and aetiology of catheter-related infections in European hospitals are mostly unknown. The present study (ESGNI-005) comprised a 1-day (22 October 2001), laboratory-based, point-prevalence survey based on a questionnaire completed by microbiology...... by these institutions was 121,363,800, and the estimated number of admissions during 2000 was 6,712,050. The total number of catheter tips processed during 2000 was 142,727, or 21/1,000 admissions, of which 23.7% were considered to be positive in the institutions using semiquantitative or quantitative techniques....... Overall, EU centres received significantly more catheter tip samples/1,000 admissions and had a significantly higher rate of 'positivity' (p...

  15. The supraclavicular fossa ultrasound view for central venous catheter placement and catheter change over guidewire.

    Science.gov (United States)

    Kim, Se-Chan; Klebach, Christian; Heinze, Ingo; Hoeft, Andreas; Baumgarten, Georg; Weber, Stefan

    2014-12-23

    The supraclavicular fossa ultrasound view can be useful for central venous catheter (CVC) placement. Venipuncture of the internal jugular veins (IJV) or subclavian veins is performed with a micro-convex ultrasound probe, using a neonatal abdominal preset with a probe frequency of 10 Mhz at a depth of 10-12 cm. Following insertion of the guidewire into the vein, the probe is shifted to the right supraclavicular fossa to obtain a view of the superior vena cava (SVC), right pulmonary artery and ascending aorta. Under real-time ultrasound view, the guidewire and its J-tip is visualized and pushed forward to the lower SVC. Insertion depth is read from guidewire marks using central venous catheter. CVC is then inserted following skin and venous dilation. The supraclavicular fossa view is most suitable for right IJV CVC insertion. If other insertion sites are chosen the right supraclavicular fossa should be within the sterile field. Scanning of the IJVs, brachiocephalic veins and SVC can reveal significant thrombosis before venipuncture. Misplaced CVCs can be corrected with a change over guidewire technique under real-time ultrasound guidance. In conjunction with a diagnostic lung ultrasound scan, this technique has a potential to replace chest radiograph for confirmation of CVC tip position and exclusion of pneumothorax. Moreover, this view is of advantage in patients with a non-p-wave cardiac rhythm were an intra-cardiac electrocardiography (ECG) is not feasible for CVC tip position confirmation. Limitations of the method are lack of availability of a micro-convex probe and the need for training.

  16. A validation study of a new nasogastric polyfunctional catheter.

    Science.gov (United States)

    Chiumello, D; Gallazzi, E; Marino, A; Berto, V; Mietto, C; Cesana, B; Gattinoni, L

    2011-05-01

    Pleural and abdominal pressure are clinically estimated by measuring the esophageal and bladder or intragastric pressure (IGP), respectively. A new nasogastric polyfunctional catheter is now commercially available, equipped with two balloons in the lower and distal part; this catheter allows simultaneous esophageal pressure (Pes) and IGP measurements and can be also used to feed the patient. We compared the Pes and IGP measured using this new device with those obtained with a standard balloon catheter taken as gold standard. Twenty-four intubated patients requiring ventilator support (mean age 64.3 ± 16.8 years, body mass index 25.3 ± 3.0 kg/m(2), and PaO(2)/FiO(2) 280.8 ± 123.4 mmHg) were enrolled. Esophageal pressure and IGP were measured with the new nasogastric polyfunctional catheter (Nutrivent, Sidam, Italy) and with a standard balloon catheter (Smart Cath Viasys, USA). The Smart Cath was first inserted in the stomach and then retracted to the esophagus to measure IGP and Pes, respectively. In each patient two paired measurements were averaged. In the Bland-Altman analysis, the bias and agreement bands for Pes, ΔPes (computed as the difference of esophageal pressure between end-inspiration and expiration), and IGP were -0.25 (-2.65 to +2.15), 0.0 (-0.9 to +0.9), and -0.45 (-2.85 to + 1.95) cmH(2)O, respectively. No side effects or complications were recorded. The new polyfunctional catheter showed a clinically acceptable validity in recording esophageal and intragastric pressure. This device should help physicians to better individualize the clinical patient management.

  17. Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction.

    Science.gov (United States)

    Roldan, Carlos J; Paniagua, Linda

    2015-09-01

    Despite the level of skill of the operator and the use of ultrasound guidance, central venous catheter (CVC) placement can result in CVC malpositioning, an unintended placement of the catheter tip in an inadequate vessel. CVC malpositioning is not a complication of central line insertion; however, undiagnosed CVC malpositioning can be associated with significant morbidity and mortality. The objectives of this review were to describe factors associated with intravascular malpositioning of CVCs inserted via the neck and chest and to offer ways of preventing, identifying, and correcting such malpositioning. A literature search of PubMed, Cochrane Library, and MD Consult was performed in June 2014. By searching for "Central line malposition" and then for "Central venous catheters intravascular malposition," we found 178 articles written in English. Of those, we found that 39 were relevant to our objectives and included them in our review. According to those articles, intravascular CVC malpositioning is associated with the presence of congenital and acquired anatomical variants, catheter insertion in left thoracic venous system, inappropriate bevel orientation upon needle insertion, and patient's body habitus variants. Although plain chest radiography is the standard imaging modality for confirming catheter tip location, signs and symptoms of CVC malpositioning even in presence of normal or inconclusive conventional radiography findings should prompt the use of additional diagnostic methods to confirm or rule out CVC malpositioning. With very few exceptions, the recommendation in cases of intravascular CVC malpositioning is to remove and relocate the catheter. Knowing the mechanisms of CVC malpositioning and how to prevent, identify, and correct CVC malpositioning could decrease harm to patients with this condition.

  18. Central Venous Catheter Intravascular Malpositioning: Causes, Prevention, Diagnosis, and Correction

    Directory of Open Access Journals (Sweden)

    Carlos J. Roldan

    2015-10-01

    Full Text Available Despite the level of skill of the operator and the use of ultrasound guidance, central venous catheter (CVC placement can result in CVC malpositioning, an unintended placement of the catheter tip in an inadequate vessel. CVC malpositioning is not a complication of central line insertion; however, undiagnosed CVC malpositioning can be associated with significant morbidity and mortality. The objectives of this review were to describe factors associated with intravascular malpositioning of CVCs inserted via the neck and chest and to offer ways of preventing, identifying, and correcting such malpositioning. A literature search of PubMed, Cochrane Library, and MD Consult was performed in June 2014. By searching for “Central line malposition” and then for “Central venous catheters intravascular malposition,” we found 178 articles written in English. Of those, we found that 39 were relevant to our objectives and included them in our review. According to those articles, intravascular CVC malpositioning is associated with the presence of congenital and acquired anatomical variants, catheter insertion in left thoracic venous system, inappropriate bevel orientation upon needle insertion, and patient’s body habitus variants. Although plain chest radiography is the standard imaging modality for confirming catheter tip location, signs and symptoms of CVC malpositioning even in presence of normal or inconclusive conventional radiography findings should prompt the use of additional diagnostic methods to confirm or rule out CVC malpositioning. With very few exceptions, the recommendation in cases of intravascular CVC malpositioning is to remove and relocate the catheter. Knowing the mechanisms of CVC malpositioning and how to prevent, identify, and correct CVC malpositioning could decrease harm to patients with this condition.

  19. The Hunter pulmonary angiography catheter for a brachiocephalic vein approach.

    Science.gov (United States)

    Rosen, Galia; Kowalik, Karen J; Ganguli, Suverano; Hunter, David W

    2006-01-01

    The purpose of this work was to describe our experience in performing pulmonary angiography using the Hunter pulmonary catheter, manufactured by Cook, Inc., which is a modified 6F pigtail catheter with a "C-shaped" curve, designed for a brachiocephalic vein approach. One hundred twenty-three patients underwent pulmonary angiograms using the Hunter catheter between August 1997 and January 2002. Operator comments were gathered in 86 (70%) of the cases. The operator was, if possible, the most junior resident on the service. Thirty-nine operators participated in the survey. Efficacy, safety, and ease of use of the catheter were determined by operators' comments and ECG observations during the procedure. Corroborating clinical data were gathered from medical records. In 68 (79%) of the procedures that were commented upon, the operator described insertion into the pulmonary artery (PA) as easy; only 2 (2%) indicated difficulty in accessing the PA. In 41 (63%) of the bilateral angiograms that were commented upon, the operator described accessing the left PA from the right PA as easy; only 6 (9%) rated it as difficult and all were with an older technique in which the catheter was withdrawn to the pulmonary bifurcation without a wire or with only the soft tip of the wire in the pigtail and then rotated to the left main pulmonary artery. Thirty-one of the 41 patients who demonstrated premature ventricular contractions (PVCs) had a previous history of heart disease. Nineteen of the 39 patients who did not have PVCs had a history of heart disease (p = 0.018). The maneuverability and shape of the Hunter catheter make pulmonary angiography an easy procedure, even for operators with minimal experience and limited technical proficiency. PVCs demonstrated a statistically significant correlation with a positive patient history for cardiac disease, rather than being a universal risk.

  20. Clinical efficacy and safety of catheter ablation for atrial fibrillation in elderly patients

    Institute of Scientific and Technical Information of China (English)

    董静

    2013-01-01

    Objective To evaluate the clinical efficacy and safty of catheter ablation for atrial fibrillation in elderly patients.Methods From September 2008 to October 2011,a total of 420 consecutive patients undergoing cathete rablation

  1. Evaluation of the safety of latrogenic lntestinal perforation during placement of percutaneous drainage catheter in rabbit

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Choon Hyeong; Oh, Joo Hyung; Park, Ga Young; Shin, Hong Sub; Kim, In Sub; Yoon, Yup; Lee, Dong Ho; Ko, Young Tae; Choi, Woo Suk; Lim, Joo Won [Kyunghee Univ. Hospital, Seoul (Korea, Republic of)

    1996-10-01

    To evaluate the safety of transgression of the bowel during intraperitoneal percutaneous catheter placement in an animal model. Eight 8-F straight catheters were percutaneously inserted into the small and large bowel of eight rabbits. In four animals, the catheters were left in place until autopsy, whereas in the remaining four, the catheters were withdrawn five days after insertion. Autopsy was performed in all animals ten days after catheter placement, and gross and microscopic examination was carried out. Transgressing the bowel during intraperitoneal percutaneous catheter placement did not contribute to any clinically significant complications. At autopsy, there was no bowel leakage, peritonitis, or abscess, although peritoneal adhesions were found around the catheter tract. Although further study is warranted, our study with an animal model indicated that transgression of the intestine during percutaneous placement of an intraabdominal catheter did not produce significant complications.

  2. Biofilm formation in long-term central venous catheters in children with cancer

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Fuursted, Kurt; Funch, Peter;

    2012-01-01

    Taurolidine has demonstrated inhibition of biofilm formation in vitro. The aim of this study was to compare the effect of catheter locking with taurolidine vs heparin in biofilm formation in central venous catheters. Forty-eight children with cancer were randomized to catheter locking by heparin (n...... = 22) or taurolidine (n = 26), respectively. After removal, catheters were examined by standardized scanning electron microscopy to assess quantitative biofilm formation. Biofilm was present if morphologically typical structures and bacterial cells were identified. Quantitative and semi......-quantitative cultures were also performed. Biofilm was identified in 23 of 26 catheters from the taurolidine group and 21 of 22 catheters from the heparin group. A positive culture was made of six of the catheters locked with taurolidine and heparin, respectively (p = 0.78). The rate of catheter-related bloodstream...

  3. Radiologic interventional retrieval of retained central venous catheter fragment in prematurity: case report

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jee Won; Jo, Jung Hyun; Park, Byeong Ho [College of Medicine, Dong-A University, Busan (Korea, Republic of)

    2007-12-15

    The fracture of a central venous catheter is a rare but potentially serious complication. Moreover, removal of the broken catheter pieces is considerably challenging, especially for premature infants. We report 3 case studies of the percutaneous transcatheter retrieval of broken catheter parts in 3 premature infants. We confirmed the location of the catheter fragments via a DSA venogram with diluted contrast media. Using the minimum amount of contrast, and extreme caution, we made certain no contrast-induced nephrotoxicity of air embolism occurred during catheter manipulation. In addition, when the broken fragment was curled or attached to the cardiac wall, we used a hook-shaped catheter to facilitate the capturing of the catheter with a loopsnare. This report demonstrates the feasibility of removing a retained catheter fragment in a premature infant using a percutaneous transcatheter approach.

  4. Adjacent central venous catheters can result in immediate aspiration of infused drugs during renal replacement therapy.

    Science.gov (United States)

    Kam, K Y R; Mari, J M; Wigmore, T J

    2012-02-01

    Dual-lumen haemodiafiltration catheters enable continuous renal replacement therapy in the critically ill and are often co-located with central venous catheters used to infuse drugs. The extent to which infusions are immediately aspirated by an adjacent haemodiafiltration catheter remains unknown. A bench model was constructed to evaluate this effect. A central venous catheter and a haemodiafiltration catheter were inserted into a simulated central vein and flow generated using centrifugal pumps within the simulated vein and haemodiafiltration circuit. Ink was used as a visual tracer and creatinine solution as a quantifiable tracer. Tracers were completely aspirated by the haemodiafiltration catheter unless the infusion was at least 1 cm downstream to the arterial port. No tracer was aspirated from catheters infusing at least 2 cm downstream. Orientation of side ports did not affect tracer elimination. Co-location of central venous and haemodiafiltration catheters may lead to complete aspiration of infusions into the haemodiafilter with resultant drug under-dosing.

  5. Balloon Dilatation for Removal of an Irretrievable Permanent Hemodialysis Catheter: The Safest Approach.

    Science.gov (United States)

    Garcarek, Jerzy; Gołębiowski, Tomasz; Letachowicz, Krzysztof; Kusztal, Mariusz; Szymczak, Maciej; Madziarska, Katarzyna; Jakuszko, Katarzyna; Zmonarski, Sławomir; Guziński, Maciej; Weyde, Wacław; Klinger, Marian

    2016-05-01

    Long-term hemodialysis catheter dwell time in the central vein predisposes to fibrin sheath development, which subsequently causes catheter malfunction or occlusion. In very rare cases, the catheter can be overgrown with fibrin and rigidly connected with the vein or heart structures. This makes its removal almost impossible and dangerous because of the possibility of serious complications, namely vein and heart wall perforation, bleeding, or catheter abruption in deep tissues. We describe two cases in which standard retrieval of long-term catheters was not possible. Balloon dilatation of catheter lumens was successfully used to increase the catheter diameter with simultaneous tearing of the fibrin sheath surrounding it. This allowed the catheter to be set free safely. Based on this experience, we present recent literature and our point of view. Copyright © 2015 International Center for Artificial Organs and Transplantation and Wiley Periodicals, Inc.

  6. Comparison of complication rates between umbilical and peripherally inserted central venous catheters in newborns

    NARCIS (Netherlands)

    Arnts, I.J.J.; Bullens, L.M.; Groenewoud, J.M.M.; Liem, K.D.

    2014-01-01

    OBJECTIVE: To compare the complication rates between umbilical central venous catheters and peripherally inserted central venous catheters in newborns and to investigate whether other variables might increase complication rates. DESIGN: A retrospective observational study. SETTING: A Level III neona

  7. Fluoroscopy guided percutaneous catheter drainage of pneumothorax in good mid-term patency with tube drainage

    Energy Technology Data Exchange (ETDEWEB)

    Park, Ga Young; Oh, Joo Hyung; Yoon, Yup; Sung, Dong Wook [Kyung Hee University Hospital, Seoul (Korea, Republic of)

    1995-10-15

    To evaluate efficacy and the safety of percutaneous catheter drainage in patients with pneumothorax that is difficult to treat with closed thoracotomy. We retrospectively reviewed effectiveness of percutaneous catheter drainage (PCD) in 10 patients with pneumothorax. The catheter was inserted under fluoroscopic guidance. Seven patients had spontaneous pneumothorax caused by tuberculosis (n =4), reptured bullae (n = 2), and histiocytosis-X (n = 1). Three patients had iatrogenic pneumothorax caused by trauma (n = 1) and surgery (n = 2). All procedures were performed by modified Seldinger's method by using 8F-20F catheter. All catheter were inserted successfully. In 9 of 10 patients, the procedure was curative without further therapy. Duration of catheter insertion ranged from 1 day to 26 days. In the remaining 1 patient in whom multiple pneumothorax occurred after operation, catheter insertion was performed twice. Percutaneous catheter drainage under fluoroscopic guidance is effective and safe procedure for treatment of pneumothorax in patients with failed closed thoracotomy.

  8. Implementation of a children's hospital-wide central venous catheter insertion and maintenance bundle

    NARCIS (Netherlands)

    K. Helder MScN (Onno); R.F. Kornelisse (René); C. van der Starre (Cynthia); D. Tibboel (Dick); C.W.N. Looman (Caspar); R.M.H. Wijnen (René); M.J. Poley (Marten); E. Ista (Erwin)

    2013-01-01

    textabstractBackground: Central venous catheter-associated bloodstream infections in children are an increasingly recognized serious safety problem worldwide, but are often preventable. Central venous catheter bundles have proved effective to prevent such infections. Successful implementation requir

  9. Nosocomial bacteremia and catheter infection by Bacillus cereus in an immunocompetent patient.

    Science.gov (United States)

    Hernaiz, C; Picardo, A; Alos, J I; Gomez-Garces, J L

    2003-09-01

    We present a case of Bacillus cereus bacteremia and catheter infection in an immunocompetent patient subjected to abdominal surgery, who recovered following central catheter removal and treatment with piperacillin/tazobactam.

  10. Natural history of malignant bone disease in breast cancer and the use of cumulative mean functions to measure skeletal morbidity

    Directory of Open Access Journals (Sweden)

    Smith Matthew R

    2009-08-01

    Full Text Available Abstract Background Bone metastases are a common cause of skeletal morbidity in patients with advanced cancer. The pattern of skeletal morbidity is complex, and the number of skeletal complications is influenced by the duration of survival. Because many patients with cancer die before trial completion, there is a need for survival-adjusted methods to accurately assess the effects of treatment on skeletal morbidity. Methods Recently, a survival-adjusted cumulative mean function model has been generated that can provide an intuitive graphic representation of skeletal morbidity throughout a study. This model was applied to the placebo-control arm of a pamidronate study in patients with malignant bone disease from breast cancer. Results Analysis by bone lesion location showed that spinal metastases were associated with the highest cumulative mean incidence of skeletal-related events (SREs, followed by chest and pelvic metastases. Metastases located in the extremities were associated with an intermediate incidence of SREs, and those in the skull were associated with the lowest incidence of SREs. Conclusion Application of this model to data from the placebo arm of this trial revealed important insight into the natural history of skeletal morbidity in patients with bone metastases. Based on these observations, treatment for the prevention of SREs is warranted regardless of lesion location except for metastases on the skull.

  11. A prospective interventional study to examine the effect of a silver alloy and hydrogel-coated catheter on the incidence of catheter-associated urinary tract infection.

    Science.gov (United States)

    Chung, P Hy; Wong, C Wy; Lai, C Kc; Siu, H K; Tsang, D Nc; Yeung, K Y; Ip, D Km; Tam, P Kh

    2017-06-01

    Catheter-associated urinary tract infection is a major hospital-acquired infection. This study aimed to analyse the effect of a silver alloy and hydrogel-coated catheter on the occurrence of catheter-associated urinary tract infection. This was a 1-year prospective study conducted at a single centre in Hong Kong. Adult patients with an indwelling urinary catheter for longer than 24 hours were recruited. The incidence of catheter-associated urinary tract infection in patients with a conventional latex Foley catheter without hydrogel was compared with that in patients with a silver alloy and hydrogel-coated catheter. The most recent definition of urinary tract infection was based on the latest surveillance definition of the National Healthcare Safety Network managed by Centers for Disease Control and Prevention. A total of 306 patients were recruited with a similar ratio between males and females. The mean (standard deviation) age was 81.1 (10.5) years. The total numbers of catheter-days were 4352 and 7474 in the silver-coated and conventional groups, respectively. The incidences of catheter-associated urinary tract infection per 1000 catheter-days were 6.4 and 9.4, respectively (P=0.095). There was a 31% reduction in the incidence of catheter-associated urinary tract infection per 1000 catheter-days in the silver-coated group. Escherichia coli was the most commonly involved pathogen (36.7%) of all cases. Subgroup analysis revealed that the protective effect of silver-coated catheter was more pronounced in long-term users as well as female patients with a respective 48% (P=0.027) and 42% (P=0.108) reduction in incidence of catheter-associated urinary tract infection. The mean catheterisation time per person was the longest in patients using a silver-coated catheter (17.0 days) compared with those using a conventional (10.8 days) or both types of catheter (13.6 days) [P=0.01]. Silver alloy and hydrogel-coated catheters appear to be effective in preventing catheter

  12. The catheter hub disinfection cap as esophageal foreign body.

    Science.gov (United States)

    Tawfik, Kareem O; Myer, Charles M; Shikary, Tasneem; Goldschneider, Kenneth R

    2015-12-01

    Disinfection caps are increasingly being used to prevent catheter-associated bloodstream infections. These devices, designed for continuous passive disinfection of catheter hubs, are typically small and often brightly colored. As such, they have the potential to become pediatric airway and esophageal foreign bodies. We report two patients who developed esophageal foreign body following ingestion of disinfection caps. Given the increasing use of these devices, it is imperative that health care providers be aware of this potential iatrogenic problem. We propose that the use of disinfection caps may not be appropriate in pediatric patients with risk factors for foreign body ingestion.

  13. Sagittal vein thrombosis caused by central vein catheter.

    Directory of Open Access Journals (Sweden)

    Feridoun Sabzi

    2015-03-01

    Full Text Available Cerebral venous thrombosis, including thrombosis of cerebral veins and major dural sinuses, is an uncommon disorder in the general population. However, it has a higher frequency among patients younger than 40 years of age, patients with thrombophilia, pregnant patients or those receiving hormonal contraceptive therapy or has foreign body such as catheter in their veins or arterial system. In this case report, we described clinical and radiological findings in a patient with protein C-S deficiency and malposition of central vein catheter.

  14. Spontaneous migration of central venous catheter tip following extubation

    Directory of Open Access Journals (Sweden)

    Balaji Prabaharan

    2014-01-01

    Full Text Available Migration of the tip of central venous catheters is not an uncommon event and the mechanism for this is not clear. Increased intrathoracic pressure due to coughing, sneezing or weight lifting, changing the body position or physical movements such as abduction or adduction of the arms is thought to be the cause of such migration. We present here a case of a patient with a port catheter tip that migrated from the left subclavian to the superior vene cava following extubation.

  15. Imaging of the complications of peripherally inserted central venous catheters

    Energy Technology Data Exchange (ETDEWEB)

    Amerasekera, S.S.H. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)], E-mail: steve.amerasekera@nhs.net; Jones, C.M.; Patel, R.; Cleasby, M.J. [Department of Radiology, Good Hope Hospital, Sutton Coldfield, Birmingham (United Kingdom)

    2009-08-15

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  16. Imaging of the complications of peripherally inserted central venous catheters.

    Science.gov (United States)

    Amerasekera, S S H; Jones, C M; Patel, R; Cleasby, M J

    2009-08-01

    Peripherally inserted central catheters (PICC) are widely used to provide central venous access, often in chronically ill patients with long-term intravenous access requirements. There are a number of significant complications related to both insertion and maintenance of PICC lines, including catheter malposition, migration, venous thrombosis, and line fracture. The incidence of these complications is likely to rise as the number of patients undergoing intravenous outpatient therapy increases, with a corresponding rise in radiologist input. This paper provides an overview of the relevant peripheral and central venous anatomy, including anatomical variations, and outlines the complications of PICC lines. Imaging examples demonstrate the range of radiological findings seen in these complications.

  17. Validation of the Accuracy and Reliability of Culturing Intravascular Catheter Segments

    Science.gov (United States)

    1992-11-24

    catheters over guidewire using the Seldinger technique , bedside plating of catheter segments and preparation of segments for transport to the...physician(s) responsible for the patient’s care, using strict aseptic technique . Sterile 2 gowns and gloves, sterile barriers and caps were required...CULTURES Catheter subsegments sent to the lab were cultured using semiquantitative technique described by Maki. 1 The catheter subsegments were

  18. Survival of dental implants in post-menopausal bisphosphonate users.

    Science.gov (United States)

    Koka, Sreenivas; Babu, Nivedhitha Malli Suresh; Norell, Aaron

    2010-07-01

    To determine whether post-menopausal women with a history of bisphosphonate use are at greater risk for implant failure or osteonecrosis of the jaw (ONJ) than an age- and gender-matched population with no history of bisphosphonate use. A retrospective chart review and phone interview was conducted of patients seen at the Mayo Clinic who had implants placed after November 2006. Bisphosphonate users were identified by medical chart review. Dental implant survival and ONJ incidence were determined in a total of 82 post-menopausal non-bisphosphonate users and 55 post-menopausal bisphosphonate users using a phone interview. Implant failures were recorded and survival percentages were calculated for comparison. ONJ was not observed consequent to implant placement in any of the bisphosphonate users or non-users. In non-users, 163 out of 166 implants were surviving for a cumulative survival rate of 98.19%. In bisphosphonate users, 120 out of 121 implants were surviving for a cumulative survival rate of 99.17%. Dental implants placed in post-menopausal women have the same survival potential regardless of whether patients have a history of bisphosphonate use. Bisphosphonate users who undergo dental implant surgery are at low risk for osteonecrosis of the jaw and a bisphosphonate "drug holiday" is not indicated in these patients. Copyright 2010 Japan Prosthodontic Society. Published by Elsevier Ltd. All rights reserved.

  19. Reducing unnecessary urinary catheter use and other strategies to prevent catheter-associated urinary tract infection: an integrative review

    Science.gov (United States)

    Meddings, Jennifer; Rogers, Mary A M; Krein, Sarah L; Fakih, Mohamad G; Olmsted, Russell N; Saint, Sanjay

    2014-01-01

    Background Catheter-associated urinary tract infections (CAUTI) are costly, common and often preventable by reducing unnecessary urinary catheter (UC) use. Methods To summarise interventions to reduce UC use and CAUTIs, we updated a prior systematic review (through October 2012), and a meta-analysis regarding interventions prompting UC removal by reminders or stop orders. A narrative review summarises other CAUTI prevention strategies including aseptic insertion, catheter maintenance, antimicrobial UCs, and bladder bundle implementation. Results 30 studies were identified and summarised with interventions to prompt removal of UCs, with potential for inclusion in the meta-analyses. By meta-analysis (11 studies), the rate of CAUTI (episodes per 1000 catheter-days) was reduced by 53% (rate ratio 0.47; 95% CI 0.30 to 0.64, p<0.001) using a reminder or stop order, with five studies also including interventions to decrease initial UC placement. The pooled (nine studies) standardised mean difference (SMD) in catheterisation duration (days) was −1.06 overall (p=0.065) including a statistically significant decrease in stop-order studies (SMD −0.37; p<0.001) but not in reminder studies (SMD, −1.54; p=0.071). No significant harm from catheter removal strategies is supported. Limited research is available regarding the impact of UC insertion and maintenance technique. A recent randomised controlled trial indicates antimicrobial catheters provide no significant benefit in preventing symptomatic CAUTIs. Conclusions UC reminders and stop orders appear to reduce CAUTI rates and should be used to improve patient safety. Several evidence-based guidelines have evaluated CAUTI preventive strategies as well as emerging evidence regarding intervention bundles. Implementation strategies are important because reducing UC use involves changing well-established habits. PMID:24077850

  20. 21 CFR 870.4210 - Cardiopulmonary bypass vascular catheter, cannula, or tubing.

    Science.gov (United States)

    2010-04-01

    ... Devices § 870.4210 Cardiopulmonary bypass vascular catheter, cannula, or tubing. (a) Identification. A cardiopulmonary bypass vascular catheter, cannula, or tubing is a device used in cardiopulmonary surgery to... 21 Food and Drugs 8 2010-04-01 2010-04-01 false Cardiopulmonary bypass vascular catheter,...

  1. Safety and feasibility of femoral catheters during physical rehabilitation in the intensive care unit.

    Science.gov (United States)

    Damluji, Abdulla; Zanni, Jennifer M; Mantheiy, Earl; Colantuoni, Elizabeth; Kho, Michelle E; Needham, Dale M

    2013-08-01

    Femoral catheters pose a potential barrier to early rehabilitation in the intensive care unit (ICU) due to concerns, such as catheter removal, local trauma, bleeding, and infection. We prospectively evaluated the feasibility and safety of physical therapy (PT) in ICU patients with femoral catheters. We evaluated consecutive medical ICU patients who received PT with a femoral venous, arterial, or hemodialysis catheter(s) in situ. Of 1074 consecutive patients, 239 (22%) received a femoral catheter (81% venous, 29% arterial, 6% hemodialysis; some patients had >1 catheter). Of those, 101 (42%) received PT interventions, while the catheter was in situ, for a total of 253 sessions over 210 medical ICU (MICU) days. On these 210 MICU days, the highest daily activity level achieved was 49 (23%) standing or walking, 57 (27%) sitting, 25 (12%) supine cycle ergometry, and 79 (38%) in-bed exercises. During 253 PT sessions, there were no catheter-related adverse events giving a 0% event rate (95% upper confidence limit of 2.1% for venous catheters). Physical therapy interventions in MICU patients with in situ femoral catheters appear to be feasible and safe. The presence of a femoral catheter should not automatically restrict ICU patients to bed rest. Copyright © 2013 Elsevier Inc. All rights reserved.

  2. The Ultrasound-Only Central Venous Catheter Placement and Confirmation Procedure.

    Science.gov (United States)

    Saul, Turandot; Doctor, Michael; Kaban, Nicole L; Avitabile, Nicholas C; Siadecki, Sebastian D; Lewiss, Resa E

    2015-07-01

    The placement of a central venous catheter remains an important intervention in the care of critically ill patients in the emergency department. We propose an ultrasound-first protocol for 3 aspects of central venous catheter placement above the diaphragm: dynamic procedural guidance, evaluation for pneumothorax, and confirmation of the catheter tip location.

  3. A novel suture method to place and adjust peripheral nerve catheters

    DEFF Research Database (Denmark)

    Rothe, C.; Steen-Hansen, C.; Madsen, M. H.;

    2015-01-01

    We have developed a peripheral nerve catheter, attached to a needle, which works like an adjustable suture. We used in-plane ultrasound guidance to place 45 catheters close to the femoral, saphenous, sciatic and distal tibial nerves in cadaver legs. We displaced catheters after their initial...

  4. Central venous catheter-related infections: Risk factors and effects of glycopeptide antibiotics

    Directory of Open Access Journals (Sweden)

    Arsenijević Ljubica

    2007-01-01

    Full Text Available INTRODUCTION Central venous catheters (CVC are used in the treatment of critically ill patients. Indications for placement of CVCs include hemodynamic monitoring, administration of intravenous fluids, medications and total parenteral nutrition. MATERIAL AND METHODS We investigated risk factors and effects of glycopeptide antibiotics on the development of central venous catheter-related infections in 300 patients treated in intensive care units. A semiquntitative culture technique was used. The investigation included: age, diagnosis on admission, catheter insertion site, catheter duration, the first or next catheter and using of glycopeptide drugs. RESULTS 91 catheters (30.3% were colonised, catheter-related infection was found in 50 catheters (16.7%. Infections were more frequent in catheters inserted through the internal jugular vein than in subclavian venous catheters; they were also more frequent if duration of catheterization was longer than seven days, but less frequent in patients who received glycopeptide antibiotics. The isolated microorganism was Staphylococcus aureus. DISCUSSION According to the literature, a number of catheter-related risk factors for infections include: insertion site, type of catheter, the number of manipulations, inadequat asepsis, lumen number, type of antiseptic. The relative importance of one risk factor over another is difficult to assess, given that studies have no priority report. CONCLUSION The duration of catheterization and the insertion site were the most frequent risk factors for infection. The use of glycopeptide antibiotics during catheterization has protective effects.

  5. Magnetic-field navigation for catheters: integrated chip for triple blood sampling

    NARCIS (Netherlands)

    Mols, B.

    2004-01-01

    Catheters are semi-rigid, hollow plastic tubes that are indispensable when it comes to local surgery inside the heart,brain,arms, legs, or lungs. But how can a surgeon tell whether the catheter is going the right way? Most hospitals still use x-ray methods to check the catheters progress. To

  6. Percutaneous transvenous retrieval of CVP catheter emboli in S. V. C.-A case report-

    Energy Technology Data Exchange (ETDEWEB)

    Zeon, Seok Kil; Lee, Deock Hee; Kim, Hong; Kim, Ok Bae [Keimyung University College of Medicine, Taegu (Korea, Republic of)

    1987-02-15

    The increasing use of the indwelling venous catheters and cardiovascular catheters has led to many iatrogenic complications. One of the most serious complications is catheter embolization, caused by inadvertent fracture of a fragment of catheter remaining within cardiovascular systems. In the catheter embolization, there are serious consequence such as thromboembolism, sepsis, cardiac arrhythmia and others. Fisher and Ferreyro (1978) reported a 71% incidence of serious morbidity or death following to intravascular foreign bodies in patients without removal. The authors experienced a case of retained central venous pressure monitoring catheter (CVP catheter) fragment extending from superior vena cava to hepatic segment of inferior vena cava. CVP catheter wa introduced into right subclavian venous route for hyperalimentation, because of poor general condition for operation of afferent loop syndrome following to resection of the gastric carcinoma with Billoth II operation (5 years age). On attempting removal of CVP catheter on recovery from afferent loop syndrome, a large portion of the CVP catheter was cut off in S.V.C. Percutaneous puncture of right femoral vein with Seldinger technique was done and 9F introducer sheath was indwelled. The helical basket of Dotter intravascular retriever set was advance through the sheath up to retained CVP catheter, and it was grasped. The retrieved CVP catheter fragment showed several tiny blood clots on surface. The patient was uneventfully recovered and was discharged asymptomatic on second day of the procedure.

  7. Transcatheter Removal of Embolized Port Catheters from the Hearts of Two Children

    Directory of Open Access Journals (Sweden)

    Osman Baspinar

    2015-01-01

    Full Text Available Embolization of a port catheter is a dangerous and serious complication. In this paper, we present two cases of children, aged 4.5 months and 6 years, in whom port catheters had embolized to the right ventricle one month and 1.5 years priorly, respectively; the port catheters were retrieved via snaring.

  8. Magnetic-field navigation for catheters: integrated chip for triple blood sampling

    NARCIS (Netherlands)

    Mols, B.

    2004-01-01

    Catheters are semi-rigid, hollow plastic tubes that are indispensable when it comes to local surgery inside the heart,brain,arms, legs, or lungs. But how can a surgeon tell whether the catheter is going the right way? Most hospitals still use x-ray methods to check the catheters progress. To navigat

  9. Study of pigtail catheter and chest tube in management of secondary spontaneous pneumothorax

    Directory of Open Access Journals (Sweden)

    Rabieh M.M. Hussein

    2017-01-01

    Conclusion: Pigtail catheter drainage is nearly effective as ICT drainage of first episode of SSP. Pigtail catheter offers a safe, tolerable method for draining SSP with a shorter duration of drainage and hospital stay more than ICT. Increasing BMI is associated with drainage failure of SSP, where obesity is considered as a risk factor with high specificity for pigtail catheter drainage failure.

  10. Placing of tunneled central venous catheters prior to induction chemotherapy in children with acute lymphoblastic leukemia

    DEFF Research Database (Denmark)

    Handrup, Mette Møller; Møller, Jens Kjølseth; Frydenberg, Morten

    2010-01-01

    BACKGROUND: Tunneled central venous catheters (CVCs) are inevitable in children with acute lymphoid leukemia (ALL). The aim of this study was to evaluate the risk of CVC-related complications in children with ALL in relation to timing of catheter placement and type of catheter. PROCEDURE: All...

  11. A cumulative entropy method for distribution recognition of model error

    Science.gov (United States)

    Liang, Yingjie; Chen, Wen

    2015-02-01

    This paper develops a cumulative entropy method (CEM) to recognize the most suitable distribution for model error. In terms of the CEM, the Lévy stable distribution is employed to capture the statistical properties of model error. The strategies are tested on 250 experiments of axially loaded CFT steel stub columns in conjunction with the four national building codes of Japan (AIJ, 1997), China (DL/T, 1999), the Eurocode 4 (EU4, 2004), and United States (AISC, 2005). The cumulative entropy method is validated as more computationally efficient than the Shannon entropy method. Compared with the Kolmogorov-Smirnov test and root mean square deviation, the CEM provides alternative and powerful model selection criterion to recognize the most suitable distribution for the model error.

  12. Experience of cumulative effects assessment in the UK

    Directory of Open Access Journals (Sweden)

    Piper Jake

    2004-01-01

    Full Text Available Cumulative effects assessment (CEA is a development of environmental impact assessment which attempts to take into account the wider picture of what impacts may affect the environment as a result of either multiple or linear projects, or development plans. CEA is seen as a further valuable tool in promoting sustainable development. The broader canvas upon which the assessment is made leads to a suite of issues such as complexity in methods and assessment of significance, the desirability of co-operation between developers and other parties, new ways of addressing mitigation and monitoring. After outlining the legislative position and the process of CEA, this paper looks at three cases studies in the UK where cumulative assessment has been carried out - the cases concern wind farms, major infrastructure and off-shore developments.

  13. Petrogenesis of the nakhlite meteorites - Evidence from cumulate mineral zoning

    Science.gov (United States)

    Harvey, Ralph P.; Mcsween, Harry Y., Jr.

    1992-01-01

    Attention is given to a simple igneous petrogenesis for the meteorite Nakhla, which was previously called into question because Mg/Fe ratios in olivine indicate substantial disequilibrium between the predominant cumulus minerals (olivine and augite). Comparative analyses of simulated diffusive zoning and the observed cumulus mineral zoning for all three nakhlites (Nakhla, Governador Valadares, and Lafayette) show that their current compositions do not necessarily reflect parental magma compositions. Diffusion has altered primary cumulus compositions to varying degrees, Nakhla being the least affected, and Lafayette being almost completely reequilibrated. Since mineral zoning in each meteorite is strongly concentric around mesostasis areas, it is inferred that reaction with intercumulus liquid has controlled the observed zoning. It is argued that the nakhlites appear to be a series of relatively simple cumulate rocks which have undergone various amounts of late-magmatic and subsolidus diffusion, possibly reflecting their relative positions in a cooling cumulate pile.

  14. Cumulative dietary exposure of the population of Denmark to pesticides

    DEFF Research Database (Denmark)

    Jensen, Bodil Hamborg; Petersen, Annette; Nielsen, Elsa

    2015-01-01

    We used the Hazard Index (HI) method to carry out a cumulative risk assessment after chronic dietary exposure to all monitored pesticides in fruit, vegetables and cereals for various consumer groups in Denmark. Residue data for all the pesticides were obtained from the Danish monitoring programme...... that included processing factors and set non-detects to ½ LOR, but limited the correction (Model 3), gave the most realistic exposure estimate. With Model 3 the HI was calculated to be 0.44 for children and 0.18 for adults, indicating that there is no risk of adverse health effects following chronic cumulative...... exposure to the pesticides found in fruit, vegetables and cereals on the Danish market. The HI was below 1 even for consumers who eat more than 550 g of fruit and vegetables per day, corresponding to 1/3 of the population. Choosing Danish-produced commodities whenever possible could reduce the HI...

  15. Determination of radionuclides and pathways contributing to cumulative dose

    Energy Technology Data Exchange (ETDEWEB)

    Napier, B.A.

    1992-12-01

    A series of scoping calculations has been undertaken to evaluate the absolute and relative contributions of different radionuclides and exposure pathways to doses that may have been received by individuals living in the vicinity of the Hanford Site. This scoping calculation (Calculation 004) examined the contributions of numerous radionuclides to cumulative dose via environmental exposures and accumulation in foods. Addressed in this calculation were the contributions to organ and effective dose of infants and adults from (1) air submersion and groundshine external dose, (2) inhalation, (3) ingestion of soil by humans, (4) ingestion of leafy vegetables, (5) ingestion of other vegetables and fruits, (6) ingestion of meat, (7) ingestion of eggs, and (8) ingestion of cows' milk from Feeding Regime 1, as described in calculation 002. This calculation specifically addresses cumulative radiation doses to infants and adults resulting from releases occurring over the period 1945 through 1972.

  16. Cumulative impacts of oil fields on northern alaskan landscapes.

    Science.gov (United States)

    Walker, D A; Webber, P J; Binnian, E F; Everett, K R; Lederer, N D; Nordstrand, E A; Walker, M D

    1987-11-06

    Proposed further developments on Alaska's Arctic Coastal Plain raise questions about cumulative effects on arctic tundra ecosystems of development of multiple large oil fields. Maps of historical changes to the Prudhoe Bay Oil Field show indirect impacts can lag behind planned developments by many years and the total area eventually disturbed can greatly exceed the planned area of construction. For example, in the wettest parts of the oil field (flat thaw-lake plains), flooding and thermokarst covered more than twice the area directly affected by roads and other construction activities. Protecting critical wildlife habitat is the central issue for cumulative impact analysis in northern Alaska. Comprehensive landscape planning with the use of geographic information system technology and detailed geobotanical maps can help identify and protect areas of high wildlife use.

  17. Effective Carrier Sensing in CSMA Networks under Cumulative Interference

    CERN Document Server

    Fu, Liqun; Huang, Jianwei

    2009-01-01

    This paper proposes and investigates the concept of a safe carrier-sensing range that can guarantee interference safe (also termed hidden-node-free) transmissions in CSMA networks under the cumulative interference model. Compared with the safe carrier-sensing range under the commonly assumed but less realistic pairwise interference model, we show that the safe carrier-sensing range required under the cumulative interference model is larger by a constant multiplicative factor. The concept of a safe carrier-sensing range, although amenable to elegant analytical results, is inherently not compatible with the conventional power threshold carrier-sensing mechanism (e.g., that used in IEEE 802.11). Specifically, the absolute power sensed by a node in the conventional mechanism does not contain enough information for it to derive its distances from other concurrent transmitter nodes. We show that, fortunately, a carrier-sensing mechanism called Incremental-Power Carrier-Sensing (IPCS) can realize the carrier-sensing...

  18. Cumulants and Correlation Functions vs the QCD phase diagram

    CERN Document Server

    Bzdak, Adam; Strodthoff, Nils

    2016-01-01

    In this note we discuss the relation of particle number cumulants and correlation functions related to them. It is argued that measuring couplings of the genuine correlation functions could provide cleaner information on possible non-trivial dynamics in heavy-ion collisions. We extract integrated multi-particle correlation functions from the presently available experimental data on proton cumulants. We find that the STAR data contain significant four-particle correlations, at least at the lower energies, with indication of changing dynamics in central collisions. We also find that these correlations are rather long-ranged in rapidity. Finally based on the signs of genuine correlation functions we provide exclusion plots for the QCD phase diagram.

  19. Cumulants of heat transfer across nonlinear quantum systems

    Science.gov (United States)

    Li, Huanan; Agarwalla, Bijay Kumar; Li, Baowen; Wang, Jian-Sheng

    2013-12-01

    We consider thermal conduction across a general nonlinear phononic junction. Based on two-time observation protocol and the nonequilibrium Green's function method, heat transfer in steady-state regimes is studied, and practical formulas for the calculation of the cumulant generating function are obtained. As an application, the general formalism is used to study anharmonic effects on fluctuation of steady-state heat transfer across a single-site junction with a quartic nonlinear on-site pinning potential. An explicit nonlinear modification to the cumulant generating function exact up to the first order is given, in which the Gallavotti-Cohen fluctuation symmetry is found still valid. Numerically a self-consistent procedure is introduced, which works well for strong nonlinearity.

  20. Seasonal climate change patterns due to cumulative CO2 emissions

    Science.gov (United States)

    Partanen, Antti-Ilari; Leduc, Martin; Damon Matthews, H.

    2017-07-01

    Cumulative CO2 emissions are near linearly related to both global and regional changes in annual-mean surface temperature. These relationships are known as the transient climate response to cumulative CO2 emissions (TCRE) and the regional TCRE (RTCRE), and have been shown to remain approximately constant over a wide range of cumulative emissions. Here, we assessed how well this relationship holds for seasonal patterns of temperature change, as well as for annual-mean and seasonal precipitation patterns. We analyzed an idealized scenario with CO2 concentration growing at an annual rate of 1% using data from 12 Earth system models from the Coupled Model Intercomparison Project Phase 5 (CMIP5). Seasonal RTCRE values for temperature varied considerably, with the highest seasonal variation evident in the Arctic, where RTCRE was about 5.5 °C per Tt C for boreal winter and about 2.0 °C per Tt C for boreal summer. Also the precipitation response in the Arctic during boreal winter was stronger than during other seasons. We found that emission-normalized seasonal patterns of temperature change were relatively robust with respect to time, though they were sub-linear with respect to emissions particularly near the Arctic. Moreover, RTCRE patterns for precipitation could not be quantified robustly due to the large internal variability of precipitation. Our results suggest that cumulative CO2 emissions are a useful metric to predict regional and seasonal changes in precipitation and temperature. This extension of the TCRE framework to seasonal and regional climate change is helpful for communicating the link between emissions and climate change to policy-makers and the general public, and is well-suited for impact studies that could make use of estimated regional-scale climate changes that are consistent with the carbon budgets associated with global temperature targets.