WorldWideScience

Sample records for cumberland steam plant

  1. Integrated Gasification SOFC Plant with a Steam Plant

    DEFF Research Database (Denmark)

    Rokni, Masoud; Pierobon, Leonardo

    2011-01-01

    enter into a burner to burn the rest of the fuel. The offgases after the burner are now used to generate steam in a Heat Recovery Steam Generator (HRSG). The generated steam is expanded in a ST to produce additional power. Thus a triple hybrid plant based on a gasification plant, a SOFC plant......A hybrid Solid Oxide Fuel Cell (SOFC) and Steam Turbine (ST) plant is integrated with a gasification plant. Wood chips are fed to the gasification plant to produce biogas and then this gas is fed into the anode side of a SOFC cycle to produce electricity and heat. The gases from the SOFC stacks...... and a steam plant is presented and studied. The plant is called as IGSS (Integrated Gasification SOFC Steam plant). Different systems layouts are presented and investigated. Electrical efficiencies up to 56% are achieved which is considerably higher than the conventional integrated gasification combined...

  2. Integrating a SOFC Plant with a Steam Turbine Plant

    DEFF Research Database (Denmark)

    Rokni, Masoud; Scappin, Fabio

    2009-01-01

    A Solid Oxide Fuel Cell (SOFC) is integrated with a Steam Turbine (ST) cycle. Different hybrid configurations are studied. The fuel for the plants is assumed to be natural gas (NG). Since the NG cannot be sent to the anode side of the SOFC directly, a desulfurization reactor is used to remove....... The off-gases after the burner are now used to generate steam in a Heat Recovery Steam Generator (HRSG). The generated steam is expanded in a ST to produce additional power. Different systems layouts are considered. Cyclic efficiencies up to 67% are achieved which is considerably higher than...

  3. Integration of torrefaction with steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Zakri, B.; Saari, J.; Sermyagina, E.; Vakkilainen, E.

    2013-09-01

    Torrefaction is one of the pretreatment technologies to enhance the fuel characteristics of biomass. The efficient and continuous operation of a torrefaction reactor, in the commercial scale, demands a secure biomass supply, in addition to adequate source of heat. Biorefinery plants or biomass-fuelled steam power plants have the potential to integrate with the torrefaction reactor to exchange heat and mass, using available infrastructure and energy sources. The technical feasibility of this integration is examined in this study. A new model for the torrefaction process is introduced and verified by the available experimental data. The torrefaction model is then integrated in different steam power plants to simulate possible mass and energy exchange between the reactor and the plants. The performance of the integrated plant is investigated for different configurations and the results are compared. (orig.)

  4. Optimum sizing of steam turbines for concentrated solar power plants

    OpenAIRE

    Andreas Poullikkas, Constantinos Rouvas, Ioannis Hadjipaschalis, George Kourtis

    2012-01-01

    In this work, a selection of the optimum steam turbine type and size for integration in concentrated solar power (CSP) plants is carried out. In particular, the optimum steam turbine input and output interfaces for a range of CSP plant capacity sizes are identified. Also, efficiency and electricity unit cost curves for various steam turbine capacities are estimated by using a combination of the Steam Pro software module of the Thermoflow Suite 18 package and the IPP v2.1 optimization software...

  5. Steam-Electric Power-Plant-Cooling Handbook

    Energy Technology Data Exchange (ETDEWEB)

    Sonnichsen, J.C.; Carlson, H.A.; Charles, P.D.; Jacobson, L.D.; Tadlock, L.A.

    1982-02-01

    The Steam-Electric Power Plant Cooling Handbook provides summary data on steam-electric power plant capacity, generation and number of plants for each cooling means, by Electric Regions, Water Resource Regions and National Electric Reliability Council Areas. Water consumption by once-through cooling, cooling ponds and wet evaporative towers is discussed and a methodology for computation of water consumption is provided for a typical steam-electric plant which uses a wet evaporative tower or cooling pond for cooling.

  6. Thermoeconomic optimization of the steam power plant

    Directory of Open Access Journals (Sweden)

    Reşat Selbaş, Hilmi Yazıcı, Arzu Şencan

    2010-05-01

    Full Text Available In this study, thermoeconomic optimization of the steam power plant with Levelized-cost method was carried out. Aim of thermoeconomy is to minimize exergy cost. With this aim, the first law and the second law of thermodynamics to each component of system were performed. Irreversibility and exergy values were obtained. Economic analysis by using exergy values was carried out. Unit electric cost for each component of system was calculated. Optimum design and operating conditions for minimum exergy cost were obtained.

  7. Parametric Optimization of Biomass Steam-and-Gas Plant

    Directory of Open Access Journals (Sweden)

    V. Sednin

    2013-01-01

    Full Text Available The paper contains a parametric analysis of the simplest scheme of a steam-and gas plant for the conditions required for biomass burning. It has been shown that application of gas-turbine and steam-and-gas plants can significantly exceed an efficiency of steam-power supply units which are used at the present moment. Optimum thermo-dynamical conditions for application of steam-and gas plants with the purpose to burn biomass require new technological solutions in the field of heat-exchange equipment designs.

  8. Combined gas/steam turbine power plants with coal fired steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Krueger, H.J.; Weirich, P.H. [ABB Kraftwerke AG, Mannheim (Germany)

    1994-12-31

    The combination of coal fired steam power plants with natural gas fired gas turbines results in an essential efficiency increase, up to 50%, requiring a portion of around one third of the fuel heat input in form of natural gas. There are two basic types of circuit arrangements in this category: in a topping process the gas turbine is connected to the steam generator on the gas side, and in a compound cycle power plant gas turbine and steam circuit are connected to each other on the water/steam side via a heat recovery steam generator. If comparable design parameters are applied slightly higher plant efficiencies can be obtained with the topping process. With respect to a higher power plant availability it is possible to operate both types of circuit arrangement without gas turbine. The specific investment cost of such combined cycle power plants is lower than that of corresponding steam power plants. Hence, they can represent economical solutions as far as the price ratio between natural gas and coal is not extremely high. In ecological respects, the advantage of this combination is a reduction of the specific CO{sub 2} emission by around 20-25%, compared with pure steam power plants. 1 ref., 9 figs., 2 tabs.

  9. 75 FR 36035 - Endangered and Threatened Wildlife and Plants; Listing the Cumberland Darter, Rush Darter...

    Science.gov (United States)

    2010-06-24

    ...-1024. For information regarding the rush darter, contact Stephen Ricks, Field Supervisor, U.S. Fish and... Fish and Wildlife Service 50 CFR Part 17 RIN 1018-AV85 Endangered and Threatened Wildlife and Plants... Endangered Throughout Their Ranges AGENCY: Fish and Wildlife Service, Interior. ACTION: Proposed...

  10. Optimum sizing of steam turbines for concentrated solar power plants

    Directory of Open Access Journals (Sweden)

    Andreas Poullikkas, Constantinos Rouvas, Ioannis Hadjipaschalis, George Kourtis

    2012-01-01

    Full Text Available In this work, a selection of the optimum steam turbine type and size for integration in concentrated solar power (CSP plants is carried out. In particular, the optimum steam turbine input and output interfaces for a range of CSP plant capacity sizes are identified. Also, efficiency and electricity unit cost curves for various steam turbine capacities are estimated by using a combination of the Steam Pro software module of the Thermoflow Suite 18 package and the IPP v2.1 optimization software tool. The results indicate that the estimated efficiency and the expected specific capital cost of the power block are very important criteria in choosing the best steam turbine size of a CSP plant. For capacity sizes of 10kWe up to 50MWe, the steam turbine efficiency increases and the steam turbine expected specific capital cost of the power block decreases at a high rate, whereas for larger sizes they remain almost constant. Thus, there is significant efficiency gains to be realized and large cost savings in increasing the turbine size up to 50MWe. Finally, although the cost of electricity of a CSP plant with capacities greater than 1MWe is significantly reduced to less than 1US$/kWh, currently such technology can only become economically viable through supporting schemes.

  11. Optimum sizing of steam turbines for concentrated solar power plants

    Energy Technology Data Exchange (ETDEWEB)

    Poullikkas, Andreas; Rouvas, Constantinos; Hadjipaschalis, Ioannis; Kourtis, Gorge [Electricity Authority of Cyprus, P.O. Box 24506, 1399 Nicosia (Cyprus)

    2012-07-01

    In this work, a selection of the optimum steam turbine type and size for integration in concentrated solar power (CSP) plants is carried out. In particular, the optimum steam turbine input and output interfaces for a range of CSP plant capacity sizes are identified. Also, efficiency and electricity unit cost curves for various steam turbine capacities are estimated by using a combination of the Steam Pro software module of the Thermoflow Suite 18 package and the IPP v2.1 optimization software tool. The results indicate that the estimated efficiency and the expected specific capital cost of the power block are very important criteria in choosing the best steam turbine size of a CSP plant. For capacity sizes of 10kWe up to 50MWe, the steam turbine efficiency increases and the steam turbine expected specific capital cost of the power block decreases at a high rate, whereas for larger sizes they remain almost constant. Thus, there is significant efficiency gains to be realized and large cost savings in increasing the turbine size up to 50MWe. Finally, although the cost of electricity of a CSP plant with capacities greater than 1MWe is significantly reduced to less than 1US$/kWh, currently such technology can only become economically viable through supporting schemes.

  12. Sorption Properties of Steam Treated Wood and Plant Fibres

    DEFF Research Database (Denmark)

    Hoffmeyer, Preben; Jensen, Signe Kamp; Jones, Dennis;

    2003-01-01

    mechanism may be the gradual filling of such micropores by lignin made to flow by further steam treatment. As a result of these counteractive mechanisms, sorption at high RH in steam treated fibres was seen to first grow, then drop and ultimately settle at a level corresponding to pure sorption at primary...... sorption sites. The annual plant fibres proved less susceptible than wood fibres to chemical breakdown from steam treatment. The component most susceptible to chemical breakdown was hemicellulose. Beech, wheat and hemp showed only a modest decrease of cellulose content, even at high temperatures, whereas...

  13. Use of reactor effluent water as steam plant boiler feed

    Energy Technology Data Exchange (ETDEWEB)

    Clukey, H.V.

    1953-12-08

    The radiological aspects of a proposal to recover some of the heat now wasted in cooling water from the Hanford reactors by using the hot water as boiler feed for the steam plants in the 100 Areas are evaluated. The radioactive material in the hot effluent water will contaminate the boiler feed water system, cause additional radiation exposure of personnel, and increase the cost of maintenance and radiation protection, but very little radioactive material will be carried over into the steam system. At present steam loads, this proposal is economically attractive; other proposals being considered may nullify any savings from this one. 21 refs., 1 fig., 10 tabs.

  14. New ferritic steels for advanced steam plants

    Energy Technology Data Exchange (ETDEWEB)

    Mayer, K.H; Koenig, H. [GEC ALSTHOM Energie GmbH, Nuremberg (Germany)

    1998-12-31

    During the last 15-20 years ferritic-martensitic 9-12 % chromium steels have been developed under international research programmes which permit inlet steam temperatures up to approx. 625 deg C and pressures up to about 300 bars, thus leading to improvements in thermal efficiency of around 8 % and a CO{sub 2} reduction of about 20 % versus conventional steam parameters. These new steels are already being applied in 13 European and 34 Japanese power stations with inlet steam temperature up to 610 deg C. This presentation will give an account of the content, scope and results of the research programmes and of the experience gained during the production of components which have been manufactured from the new steels. (orig.) 13 refs.

  15. Vortex Pressure-Reducing Desuperheating Plants and Steam Coolers

    Directory of Open Access Journals (Sweden)

    V. Kascheev

    2012-01-01

    Full Text Available The authors have developed and tested the entire device class that appeared as a result of fundamental investigations of multiphase flows in centrifugal force fields, understanding of process mechanism occurring in them and their mathematical description for optimization. Method for reduction of pressure and steam temperature in vortex pressure-reducing desuperheating plants and steam coolers has been proposed for the first time in the paper.

  16. The 700{sup o}C steam turbine power plant status of development and outlook

    Energy Technology Data Exchange (ETDEWEB)

    Edelmann, Heiner; Effert, Martin; Wieghardt, Kai; Kirchner, Holger

    2007-08-15

    This paper appraises the current development status of the 700{sup o}C steam power plant under consideration of process optimisation as well as design aspects of the steam turbine and steam generator. The results for a compact arrangement of the steam turbine and steam generator are also presented. Based on a cycle analysis, a net efficiency between 49.3% and 51.4% can be achieved with the 700{sup o}C steam power plant depending on the implementation and based on an inland plant site. No competing development activities for the 700{sup o}C steam power plant are known from the USA or Japan.

  17. Fossil-fired steam/electric gypsum plant + wallboard plant + powerplant = win-win-win

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-06-01

    The Tennessee Valley Authority has invested in a wall board plant adjacent to its Cumberland power plant to process gypsum slurry. Synmat built the gypsum processing plant to dewater and concentrate the slurry to produce gypsum cake; Temple-Inland build a wallboard plant on 124 acres nearby, the two facilities being linked by conveyor. A 20-ft-high hill of gypsum that had accumulated since 1994 and 1999 when the wallboard plant was built is utilized to meet shortfalls in raw material. The slurry is retrieved from a 10-ft deep water-filled pit that was dug into the stockpile to accept an unmanned floating pump dredge and then pumped through a 6-in line to the Synmat plant. 3 photos.

  18. Topping PCFB combustion plant with supercritical steam pressure

    Energy Technology Data Exchange (ETDEWEB)

    Robertson, A. [Foster Wheeler Development Corp., Livingston, NJ (United States); White, J. [Parsons Power Group Inc., Reading, PA (United States)

    1997-11-01

    Research is being conducted to develop a new type of coal fired plant for electric power generation. This new type of plant, called a second generation or topping pressurized circulating fluidized bed combustion (topping PCFB) plant, offers the promise of efficiencies greater than 46 percent (HHV), with both emissions and a cost of electricity that are significantly lower than conventional pulverized coal fired plants with scrubbers. The topping PCFB plant incorporates the partial gasification of coal in a carbonizer, the combustion of carbonizer char in a pressurized circulating fluidized bed combustor (PCFB), and the combustion of carbonizer fuel gas in a topping combustor to achieve gas turbine inlet temperatures of 2,300 F and higher. After completing pilot plant tests of a carbonizer, a PCFB, and a gas turbine topping combustor, all being developed for this new plant, the authors calculated a higher heating value efficiency of 46.2 percent for the plant. In that analysis, the plant operated with a conventional 2,400 psig steam cycle with 1,000 F superheat and reheat steam and a 2.5 inch mercury condenser back pressure. This paper identifies the efficiency gains that this plant will achieve by using supercritical pressure steam conditions.

  19. Effects of Visual Grading on Northern Red Oak (Quercus rubra L. Seedlings Planted in Two Shelterwood Stands on the Cumberland Plateau of Tennessee, USA

    Directory of Open Access Journals (Sweden)

    Stacy L. Clark

    2015-10-01

    Full Text Available Artificial regeneration of oak has been generally unsuccessful in maintaining the oak component in productive upland forests of eastern North America. We tested visual grading effects on quality-grown northern red oak (Quercus rubra seedlings planted in two submesic stands on the Cumberland Plateau escarpment of Tennessee, USA. Seedlings were grown for one year using advanced fertilization and irrigation protocols to increase overall size of seedlings, but large variability in size was still evident. Seedlings were divided into two grades prior to planting. The “standard” grade represented seedlings that had undergone a light culling, and the “premium” grade represented the highest quality seedlings. Seven years after planting in a midstory-removal stand, 50 percent of trees survived, growth was negligible, and seedling grade had no effect on survival and yearly growth. In a shelterwood harvest stand, premium grade seedlings had taller height and larger basal diameter (BD (241 cm and 29.5 mm, respectively compared to standard seedlings (201 cm and 25.9 mm, respectively, and a two-year height growth advantage was achieved by planting premium grade compared to standard grade seedlings. Competitive ability and planting shock were similar between grades, and we postulate that an exceptional drought and large size variability in both grades equalized response. While our findings should be confirmed through additional testing, they suggest currently accepted seedling quality standards for northern red oak should be refined to improve regeneration efforts on productive sites in the eastern United States.

  20. Power Plants, Steam and Gas Turbines WebQuest

    Science.gov (United States)

    Ulloa, Carlos; Rey, Guillermo D.; Sánchez, Ángel; Cancela, Ángeles

    2012-01-01

    A WebQuest is an Internet-based and inquiry-oriented learning activity. The aim of this work is to outline the creation of a WebQuest entitled "Power Generation Plants: Steam and Gas Turbines." This is one of the topics covered in the course "Thermodynamics and Heat Transfer," which is offered in the second year of Mechanical…

  1. Topping gas turbines improve steam power plant efficiency

    Energy Technology Data Exchange (ETDEWEB)

    Lezuo, A. (Siemens AG, Erlangen (Germany, F.R.). KWU Group)

    An interesting option for improving the efficiency and output of an existing conventional steam power plant is to convert it into a combined steam-and-gas cycle power plant by adding a topping gas turbine. The investment involved is relatively low, the payback period is short, and the low specific fuel consumption makes it possible to save on overall running costs. At the same time, the amount of residue for disposal and also pollutant emissions are drastically reduced. This article describes the configuration of a fully-fired combined-cycle power plant and discusses thermodynamic design and efficiency, operational aspects, emissions and residues and investment and economic viability. Both coal-fired and gas or oil-fired steam power plants can be converted by adding a topping cycle and the investment cost is about 20% of the cost of a new plant with the same output rating as the plant to be converted. Conversion reduces pollutant emission and residues produced (SO{sub 2}, NO{sub x}, CO{sub 2}, dust, ash, gypsum, waste heat). 4 figs.

  2. Direct flash steam geothermal power plant assessment

    Science.gov (United States)

    Alt, T. E.

    1982-01-01

    The objective was to analyze the capacity and availability factors of an operating direct flash geothermal power plant. System and component specifications, operating procedures, maintenance history, malfunctions, and outage rate are discussed. The plant studied was the 75 MW(e) geothermal power plant at Cerro Prieto, Mexico, for the years 1973 to 1979. To describe and assess the plant, the project staff reviewed documents, visited the plant, and met with staff of the operating utility. The high reliability and availability of the plant was documented and actions responsible for the good performance were identified and reported. The results are useful as guidance to US utilities considering use of hot water geothermal resources for power generation through a direct flash conversion cycle.

  3. Existing large steam power plant upgraded for hydrogen production

    Energy Technology Data Exchange (ETDEWEB)

    Galanti, L.; Franzoni, A.; Traverso, A.; Massardo, A.F. [University of Genoa, Genoa (Italy)

    2011-05-15

    This paper presents and discusses the results of a complete thermoeconomic analysis of an integrated power plant for co-production of electricity and hydrogen via pyrolysis and gasification processes fed by various coals and mixture of coal and biomass, applied to an existing large steam power plant (ENEL Brindisi power plant - 660 MWe). Two different technologies for the syngas production section are considered: pyrolysis process and direct pressurized gasification. Moreover, the proximity of a hydrogen production and purification plants to an existing steam power plant favors the inter-exchange of energy streams, mainly in the form of hot water and steam, which reduces the costs of auxiliary equipment. The high quality of the hydrogen would guarantee its usability for distributed generation and for public transport. The results were obtained using WTEMP thermoeconomic software, developed by the Thermochemical Power Group of the University of Genoa, and this project has been carried out within the framework of the FISR National project 'Integrated systems for hydrogen production and utilization in distributed power generation'.

  4. Failure of steam line causes determined by NDT testing in power and heating plants

    Directory of Open Access Journals (Sweden)

    Srdjan Bulatovic

    2013-10-01

    Full Text Available This paper examines leakage and damages of steam and provides an overview of NDT testing in order to determine the cause of steam lines failure in power plants and heating plants. This approach may be applied to similar structures and its application in preventive maintenance would help extend the life of steam pipes.

  5. SELECTION OF RUSSIAN STEAM TURBINES FOR THE VIETNAMESE COMBINED GASSTEAM PLANT. THE INFLUENCE OF THE EFFICIENCY OF HIGH-PRESSURE CYLINDER OF STEAM TURBINE K-300-240-2 ON THE POWER OF A GAS-STEAM PLANT IN VIETNAM

    Directory of Open Access Journals (Sweden)

    Pham A. H.

    2015-06-01

    Full Text Available The article looks at the current state of energy in Vietnam and the selection of new Russian steam turbines for operation in combined gas-steam plant in Vietnam. The calculated results of thermal performance scheme 3x1 with combined gas-steam plant 1090 MW based on the Russian steam turbines K-330-240-2 and on the steam turbines TS2A40 Mitsubishi (station PhuMy-1, Vietnam. It also looks at the influence of the efficiency of high-pressure cylinders of Russian steam turbine K-330-240-2 on the efficiency and power of a gas-steam plant 3x1 with 1090 MW, increasing the efficiency of high-pressure cylinder of steam turbine through the use of honeycomb seals in flow part

  6. Studies on Steam Absorption Chillers Performance at a Cogeneration Plant

    Directory of Open Access Journals (Sweden)

    Abd Majid Mohd Amin

    2014-07-01

    Full Text Available Absorption chillers at cogeneration plants generate chilled water using steam supplied by heat recovery steam generators. The chillers can be of either single-effect or double effect configuration and the coefficient of performance (COP depends on the selection made. The COP varies from 0.7 to 1.2 depending on the types of chillers. Single effect chillers normally have COP in the range of 0.68 to 0.79. Double effect chillers COP are higher and can reach 1.2. However due to factors such as inappropriate operations and maintenance practices, COP could drop over a period of time. In this work the performances of double effect steam absorption chillers at a cogeneration plant were studied. The study revealed that during the period of eleven years of operation the COP of the chillers deteriorated from 1.25 to 0.6. Regression models on the operation data indicated that the state of deterioration was projected to persist. Hence, it would be recommended that the chillers be considered for replacement since they had already undergone a series of costly repairs.

  7. Thermodynamic analysis of a FBCC steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Eskin, Nurdil; Oezdemir, Koray [Faculty of Mechanical Engineering, Istanbul Technical Univ., 34437 Istanbul (Turkey); Gungor, Afsin [Dept. of Mechanical Engineering, Faculty of Engineering and Architecture, Nigde Univ., 51100 Nigde (Turkey)

    2009-09-15

    This article presents the analysis of first and second laws of thermodynamics in a 7.7 MW steam power plant located in Torbali (Izmir, Turkey). It involves a fluidized bed, a waste heat boiler (WHB) and an economizer as subsystems. Fans, pumps, cyclone and chimney are also considered through the analysis as auxiliary systems in the thermal plant. The analysis is performed for the whole system and subsystems by considering the available energy balance. In this analysis which consists of a detailed fluidized bed coal combustor (FBCC) model, the amount of irreversibilities occurring in the system is calculated at each location. Analysis results are compared with the test results obtained from the measurements at several locations in the system and good agreement is observed. These measured values are the temperatures at three levels in the FBCC and boiler, economizer exit temperatures as well as flue gas composition at the boiler exit and steam flow rate. The maximum error observed in temperature values and steam flow rate is about 3.03% and 4.03%, respectively. Through the developed and validated model, effects of excess air and ambient temperature on first and second law efficiency of the subsystems and overall system are investigated. The second-law analysis reveals that the FBCC has the largest irreversibility, with about 80.4% of the total system exergy loss. The FBCC temperature, first and second law efficiencies decrease 19.8%, 5.1% and 5.2%, respectively, as the excess air increases from 10% to 70%. Also steam flow rate decreases 5.1%. As the ambient temperature increases from 25 to 45 C, the FBCC temperature, system first and second law efficiencies increase 0.8%, 1.3%, and 1.3%, respectively. (author)

  8. Assessment of steam explosion impact on KNGR plant

    Energy Technology Data Exchange (ETDEWEB)

    Hwang, Moon Kyu; Park, Soo Yong; Park, Ik Kyu

    1999-03-01

    In present day light water reactors, if complete and prolonged failure of normal and emergency coolant flow occurs, fission product decay heat could cause melting of the reactor fuel. If the molten fuel mass accumulates it may relocate into reactor lower plenum and if the lower head fails it may eventually be brought into the reactor cavity. In such course of core melt relocation, the opportunity for fuel-coolant interactions (FCI) arises as the core melt relocates into water pool in reactor vessel as well as in reactor cavity and also, as a consequence of implementing accident management strategies involving water addition to a degraded or molten core. This report presents the methodologies and their results for assessment of steam explosion impact on KNGR plant integrity. Both in-vessel and ex-vessel phenomena are addressed. For in-vessel steam explosion, TRACER-II code is used for assessment of pressure load, while bounding calculations are applied for ex-vessel analysis. Analysis shows that the integrity of reactor pressure vessel lower head is preserved during the in-vessel event and the probability that the containment integrity is challenged is very low, even when ex-vessel steam explosion is allowed due to reactor vessel failure. (Author). 15 refs., 2 tabs., 4 figs.

  9. Second law analysis of a conventional steam power plant

    Science.gov (United States)

    Liu, Geng; Turner, Robert H.; Cengel, Yunus A.

    1993-01-01

    A numerical investigation of exergy destroyed by operation of a conventional steam power plant is computed via an exergy cascade. An order of magnitude analysis shows that exergy destruction is dominated by combustion and heat transfer across temperature differences inside the boiler, and conversion of energy entering the turbine/generator sets from thermal to electrical. Combustion and heat transfer inside the boiler accounts for 53.83 percent of the total exergy destruction. Converting thermal energy into electrical energy is responsible for 41.34 percent of the total exergy destruction. Heat transfer across the condenser accounts for 2.89 percent of the total exergy destruction. Fluid flow with friction is responsible for 0.50 percent of the total exergy destruction. The boiler feed pump turbine accounts for 0.25 percent of the total exergy destruction. Fluid flow mixing is responsible for 0.23 percent of the total exergy destruction. Other equipment including gland steam condenser, drain cooler, deaerator and heat exchangers are, in the aggregate, responsible for less than one percent of the total exergy destruction. An energy analysis is also given for comparison of exergy cascade to energy cascade. Efficiencies based on both the first law and second law of thermodynamics are calculated for a number of components and for the plant. The results show that high first law efficiency does not mean high second law efficiency. Therefore, the second law analysis has been proven to be a more powerful tool in pinpointing real losses. The procedure used to determine total exergy destruction and second law efficiency can be used in a conceptual design and parametric study to evaluate the performance of other steam power plants and other thermal systems.

  10. Second law analysis of a conventional steam power plant

    Science.gov (United States)

    Liu, Geng; Turner, Robert H.; Cengel, Yunus A.

    1993-11-01

    A numerical investigation of exergy destroyed by operation of a conventional steam power plant is computed via an exergy cascade. An order of magnitude analysis shows that exergy destruction is dominated by combustion and heat transfer across temperature differences inside the boiler, and conversion of energy entering the turbine/generator sets from thermal to electrical. Combustion and heat transfer inside the boiler accounts for 53.83 percent of the total exergy destruction. Converting thermal energy into electrical energy is responsible for 41.34 percent of the total exergy destruction. Heat transfer across the condenser accounts for 2.89 percent of the total exergy destruction. Fluid flow with friction is responsible for 0.50 percent of the total exergy destruction. The boiler feed pump turbine accounts for 0.25 percent of the total exergy destruction. Fluid flow mixing is responsible for 0.23 percent of the total exergy destruction. Other equipment including gland steam condenser, drain cooler, deaerator and heat exchangers are, in the aggregate, responsible for less than one percent of the total exergy destruction. An energy analysis is also given for comparison of exergy cascade to energy cascade. Efficiencies based on both the first law and second law of thermodynamics are calculated for a number of components and for the plant. The results show that high first law efficiency does not mean high second law efficiency. Therefore, the second law analysis has been proven to be a more powerful tool in pinpointing real losses. The procedure used to determine total exergy destruction and second law efficiency can be used in a conceptual design and parametric study to evaluate the performance of other steam power plants and other thermal systems.

  11. Determination of steam wetness in the steam-generating equipment of nuclear power plants

    Science.gov (United States)

    Gorburov, V. I.; Gorburov, D. V.; Kuz'min, A. V.

    2012-05-01

    Calculation and experimental methods for determining steam wetness in horizontal steam generators for nuclear power stations equipped with VVER reactors, namely, the classic salt technique and calculations based on operating parameters are discussed considered and compared.

  12. Steam generators, industrial power plants, and cogeneration plants. Lectures; Dampferzeuger, Industrie- und Heizkraftwerke 2010. Vortraege

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    The proceedings of the meeting on steam generators, industrial power plants, and cogeneration plants include the following lectures: Assignments and scopes of the VGB working group ''industry and thermal power plants, BHKW''. Combustion power and process control - application of feed grate firing in industrial technology - experiences and perspectives. A new possibility of biomass co-combustion. Biomass co-combustion in Vattenfall Waerme AG. Biomass plant with optimized control. The new energy supply concept for the paper plant in Plattling. Efficient steam boiler facilities for industry and thermal power plants - case studies. Adaptation of flue gas purification for co-combustion with experiences of prototype plants. Modern risk and insurance management for power plants. Reliability oriented maintenance. Surrogate fuel IHKW Gersthofen - planning, construction and preliminary operational experiences. Assignments and scopes of the VGB working group ''steam generators''. New developments in process safety management of E.ON UK coal-fired power plants. Station-supply reduction by power drive reconstruction to frequency control - modern injection technology at high plant parameters. Self-optimizing control of fuel/air regulation. CO{sub 2} reduction by automatic power plant modeling. Virtual reality as QA tool in 3D planning. Thermodynamic studies in power plants using VDI 2048. Heating surface cleaning with explosion generators - an alternative to soot blowers. results of laboratory study on urgent material questions.

  13. Modeling and Optimization of the Steam Turbine Network of an Ethylene Plant

    Institute of Scientific and Technical Information of China (English)

    LI Zeqiu; ZHAO Liang; DU Wenli; QIAN Feng

    2013-01-01

    In this paper,we developed a hybrid model for the steam turbines of a utility system,which combines an improved neural network model with the thermodynamic model.Then,a nonlinear programming (NLP) model of the steam turbine network is formulated by utilizing the developed steam turbine models to minimize the total steam cost for the whole steam turbine network.Finally,this model is applied to optimize the steam turbine network of an ethylene plant.The obtained results demonstrate that this hybrid model can accurately estimate and evaluate the performance of steam turbines,and the significant cost savings can be made by optimizing the steam turbine network operation at no capital cost.

  14. Numerical Research of Steam and Gas Plant Efficiency of Triple Cycle for Extreme North Regions

    Directory of Open Access Journals (Sweden)

    Galashov Nikolay

    2016-01-01

    Full Text Available The present work shows that temperature decrease of heat rejection in a cycle is necessary for energy efficiency of steam turbine plants. Minimum temperature of heat rejection at steam turbine plant work on water steam is 15°C. Steam turbine plant of triple cycle where lower cycle of steam turbine plant is organic Rankine cycle on low-boiling substance with heat rejection in air condenser, which safely allows rejecting heat at condensation temperatures below 0°C, has been offered. Mathematical model of steam and gas plant of triple cycle, which allows conducting complex researches with change of working body appearance and parameters defining thermodynamic efficiency of cycles, has been developed. On the basis of the model a program of parameters and index cycles design of steam and gas plants has been developed in a package of electron tables Excel. Numerical studies of models showed that energy efficiency of steam turbine plants of triple cycle strongly depend on low-boiling substance type in a lower cycle. Energy efficiency of steam and gas plants net 60% higher can be received for steam and gas plants on the basis of gas turbine plant NK-36ST on pentane and its condensation temperature below 0°C. It was stated that energy efficiency of steam and gas plants net linearly depends on condensation temperature of low-boiling substance type and temperature of gases leaving reco very boiler. Energy efficiency increases by 1% at 10% decrease of condensation temperature of pentane, and it increases by 0.88% at 15°C temperature decrease of gases leaving recovery boiler.

  15. Worldwide assessment of steam-generator problems in pressurized-water-reactor nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Woo, H.H.; Lu, S.C.

    1981-09-15

    Objective is to assess the reliability of steam generators of pressurized water reactor (PWR) power plants in the United States and abroad. The assessment is based on operation experience of both domestic and foreign PWR plants. The approach taken is to collect and review papers and reports available from the literature as well as information obtained by contacting research institutes both here and abroad. This report presents the results of the assessment. It contains a general background of PWR plant operations, plant types, and materials used in PWR plants. A review of the worldwide distribution of PWR plants is also given. The report describes in detail the degradation problems discovered in PWR steam generators: their causes, their impacts on the performance of steam generators, and the actions to mitigate and avoid them. One chapter is devoted to operating experience of PWR steam generators in foreign countries. Another discusses the improvements in future steam generator design.

  16. Solar steam supply: Initial operation of a plant

    OpenAIRE

    Krüger, Dirk; Lichtenthäler, Niels; Dersch, Jürgen; Schenk, Heiko; Hennecke, Klaus; Anthrakidis, Anette; Rusack, Markus; Lokurlu, Ahmet; Saidi, Karim; Walder, Marcus; Fischer, Stephan; Wirth, Hans Peter

    2011-01-01

    This paper describes experiences in operating a parabolic trough collector field for process heat supply by direct steam generation. The solar steam generator has been running automatically since its start in 2010 except for a winter pause up to now, August 2011, without any malfunction. It has supplied steam at 4 bar absolute and 143°C to the main production steam line on sunny days. Direct steam generation has proven to be a viable technology to supply saturated steam to an industrial st...

  17. Incorporating supercritical steam turbines into molten-salt power tower plants :

    Energy Technology Data Exchange (ETDEWEB)

    Pacheco, James Edward; Wolf, Thorsten; Muley, Nishant

    2013-03-01

    Sandia National Laboratories and Siemens Energy, Inc., examined 14 different subcritical and supercritical steam cycles to determine if it is feasible to configure a molten-salt supercritical steam plant that has a capacity in the range of 150 to 200 MWe. The effects of main steam pressure and temperature, final feedwater temperature, and hot salt and cold salt return temperatures were determined on gross and half-net efficiencies. The main steam pressures ranged from 120 bar-a (subcritical) to 260 bar-a (supercritical). Hot salt temperatures of 566 and 600ÀC were evaluated, which resulted in main steam temperatures of 553 and 580ÀC, respectively. Also, the effects of final feedwater temperature (between 260 and 320ÀC) were evaluated, which impacted the cold salt return temperature. The annual energy production and levelized cost of energy (LCOE) were calculated using the System Advisory Model on 165 MWe subcritical plants (baseline and advanced) and the most promising supercritical plants. It was concluded that the supercritical steam plants produced more annual energy than the baseline subcritical steam plant for the same-size heliostat field, receiver, and thermal storage system. Two supercritical steam plants had the highest annual performance and had nearly the same LCOE. Both operated at 230 bar-a main steam pressure. One was designed for a hot salt temperature of 600ÀC and the other 565ÀC. The LCOEs for these plants were about 10% lower than the baseline subcritical plant operating at 120 bar-a main steam pressure and a hot salt temperature of 565ÀC. Based on the results of this study, it appears economically and technically feasible to incorporate supercritical steam turbines in molten-salt power tower plants.

  18. Steam Turbine Materials for Ultrasupercritical Coal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Viswanathan, R.; Hawk, J.; Schwant, R.; Saha, D.; Totemeier, T.; Goodstine, S.; McNally, M.; Allen, D. B.; Purgert, Robert

    2009-06-30

    The Ultrasupercritical (USC) Steam Turbine Materials Development Program is sponsored and funded by the U.S. Department of Energy and the Ohio Coal Development Office, through grants to Energy Industries of Ohio (EIO), a non-profit organization contracted to manage and direct the project. The program is co-funded by the General Electric Company, Alstom Power, Siemens Power Generation (formerly Siemens Westinghouse), and the Electric Power Research Institute, each organization having subcontracted with EIO and contributing teams of personnel to perform the requisite research. The program is focused on identifying, evaluating, and qualifying advanced alloys for utilization in coal-fired power plants that need to withstand steam turbine operating conditions up to 760°C (1400°F) and 35 MPa (5000 psi). For these conditions, components exposed to the highest temperatures and stresses will need to be constructed from nickel-based alloys with higher elevated temperature strength than the highchromium ferritic steels currently used in today's high-temperature steam turbines. In addition to the strength requirements, these alloys must also be weldable and resistant to environmental effects such as steam oxidation and solid particle erosion. In the present project, candidate materials with the required creep strength at desired temperatures have been identified. Coatings that can resist oxidation and solid particle erosion have also been identified. The ability to perform dissimilar welds between nickel base alloys and ferritic steels have been demonstrated, and the properties of the welds have been evaluated. Results of this three-year study that was completed in 2009 are described in this final report. Additional work is being planned and will commence in 2009. The specific objectives of the future studies will include conducting more detailed evaluations of the weld-ability, mechanical properties and repair-ability of the selected candidate alloys for rotors

  19. Steam generator tube degradation at the Doel 4 plant influence on plant operation and safety

    Energy Technology Data Exchange (ETDEWEB)

    Scheveneels, G. [AIB-Vincotte Nuclear, Brussels (Belgium)

    1997-02-01

    The steam generator tubes of Doel 4 are affected by a multitude of corrosion phenomena. Some of them have been very difficult to manage because of their extremely fast evolution, non linear evolution behavior or difficult detectability and/or measurability. The exceptional corrosion behavior of the steam generator tubes has had its drawbacks on plant operation and safety. Extensive inspection and repair campaigns have been necessary and have largely increased outage times and radiation exposure to personnel. Although considerable effort was invested by the utility to control corrosion problems, non anticipated phenomena and/or evolution have jeopardized plant safety. The extensive plugging and repairs performed on the steam generators have necessitated continual review of the design basis safety studies and the adaptation of the protection system setpoints. The large asymmetric plugging has further complicated these reviews. During the years many preventive and recently also defence measures have been implemented by the utility to manage corrosion and to decrease the probability and consequences of single or multiple tube rupture. The present state of the Doel 4 steam generators remains troublesome and further examinations are performed to evaluate if continued operation until June `96, when the steam generators will be replaced, is justified.

  20. Thermodynamic Investigation of an Integrated Gasification Plant with Solid Oxide Fuel Cell and Steam Cycles

    DEFF Research Database (Denmark)

    Rokni, Masoud

    2012-01-01

    A gasification plant is integrated on the top of a solid oxide fuel cell (SOFC) cycle, while a steam turbine (ST) cycle is used as a bottoming cycle for the SOFC plant. The gasification plant was fueled by woodchips to produce biogas and the SOFC stacks were fired with biogas. The produced gas...... was rather clean for feeding to the SOFC stacks after a simple cleaning step. Because all the fuel cannot be burned in the SOFC stacks, a burner was used to combust the remaining fuel. The off-gases from the burner were then used to produce steam for the bottoming steam cycle in a heat recovery steam...... generator (HRSG). The steam cycle was modeled with a simple single pressure level. In addition, a hybrid recuperator was used to recover more energy from the HRSG and send it back to the SOFC cycle. Thus two different configurations were investigated to study the plants characteristic. Such system...

  1. Humid Air Turbine as a Primary Link of a Coal-Fired Steam Power Plant

    Directory of Open Access Journals (Sweden)

    Jan T. Szargut

    2000-06-01

    Full Text Available Outlet gases of the humid air turbine (having a temperature of about 125 oC and great content of steam can be used for the preheating of feed water of the steam power plant fueled with coal. So the efficiency of the plant can be increased and its ecological indices can be improved. The attainable incremental efficiency of the humid air turbine and the increased efficiency of the combined plant has been determined for three variants of the repowering of an existing steam power plant. The variant presented in Figure 4 is recommended for practical application.

  2. Power Plants, Steam and Gas Turbines WebQuest

    Directory of Open Access Journals (Sweden)

    Carlos Ulloa

    2012-10-01

    Full Text Available A WebQuest is an Internet-based and inquiry-oriented learning activity. The aim of this work is to outline the creation of a WebQuest entitled “Power Generation Plants: Steam and Gas Turbines.” This is one of the topics covered in the course “Thermodynamics and Heat Transfer,” which is offered in the second year of Mechanical Engineering at the Defense University Center at the Naval Academy in Vigo, Spain. While participating in the activity, students will be divided into groups of no more than 10 for seminars. The groups will create PowerPoint presentations that include all of the analyzed aspects. The topics to be discussed during the workshop on power plant turbines are the: (1 principles of operation; (2 processes involved; (3 advantages and disadvantages; (4 efficiency; (5 combined cycle; and (6 transversal competences, such as teamwork, oral and written presentations, and analysis and synthesis of information. This paper presents the use of Google Sites as a guide to the WebQuest so that students can access all information online, including instructions, summaries, resources, and information on qualifications.

  3. Procedure for estimating nonfuel operation and maintenance costs for large steam-electric power plants

    Energy Technology Data Exchange (ETDEWEB)

    Myers, M.L.; Fuller, L.C.

    1979-01-01

    Revised guidelines are presented for estimating annual nonfuel operation and maintenance costs for large steam-electric power plants, specifically light-water-reactor plants and coal-fired plants. Previous guidelines were published in October 1975 in ERDA 76-37, a Procedure for Estimating Nonfuel Operating and Maintenance Costs for Large Steam-Electric Power Plants. Estimates for coal-fired plants include the option of limestone slurry scrubbing for flue gas desulfurization. A computer program, OMCOST, is also presented which covers all plant options.

  4. Thermodynamic analysis of heat recovery steam generator in combined cycle power plant

    Directory of Open Access Journals (Sweden)

    Ravi Kumar Naradasu

    2007-01-01

    Full Text Available Combined cycle power plants play an important role in the present energy sector. The main challenge in designing a combined cycle power plant is proper utilization of gas turbine exhaust heat in the steam cycle in order to achieve optimum steam turbine output. Most of the combined cycle developers focused on the gas turbine output and neglected the role of the heat recovery steam generator which strongly affects the overall performance of the combined cycle power plant. The present paper is aimed at optimal utilization of the flue gas recovery heat with different heat recovery steam generator configurations of single pressure and dual pressure. The combined cycle efficiency with different heat recovery steam generator configurations have been analyzed parametrically by using first law and second law of thermodynamics. It is observed that in the dual cycle high pressure steam turbine pressure must be high and low pressure steam turbine pressure must be low for better heat recovery from heat recovery steam generator.

  5. CANDU steam generator life management: laboratory data and plant experience

    Energy Technology Data Exchange (ETDEWEB)

    Tapping, R.L. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada); Nickerson, J.H.; Subash, N. [Atomic Energy of Canada Limited, Mississauga, Ontario (Canada); Wright, M.D

    2001-10-01

    As CANDU reactors enter middle age, and the potential value of the plants in a deregulated market is realized, life management and life extension issues become increasingly important. An accurate assessment of critical components, such as the CANDU 6 steam generators (SGs), is crucial for successful life extension, and in this context, material issues are a key factor. For example, service experience with Alloy 900 tubing indicates very low levels of degradation within CANDU SGs; the same is also noted worldwide. With little field data for extrapolation, life management and life extension decisions for the tube bundles rely heavily on laboratory data. Similarly, other components of the SGs, in particular the secondary side internals, have only limited inspection data upon which to base a condition assessment. However, in this case there are also relatively little laboratory data. Decisions on life management and life extension are further complicated--not only is inspection access often restricted, but repair or replacement options for internal components are, by definition, also limited. The application of CANDU SG life management and life extension requires a judicious blend of in-service data, laboratory research and development (R and D) and materials and engineering judgment. For instance, the available laboratory corrosion and fretting wear data for Alloy 800 SG tubing have been compared with plant experience (with all types of tubing), and with crevice chemistry simulations, in order to provide an appropriate inspection guide for a 50-year SG life. A similar approach has been taken with other SG components, where the emphasis has been on known degradation mechanisms worldwide. This paper provides an outline of the CANDU SG life management program, including the results to date, a summary of the supporting R and D program showing the integration with condition assessment and life management activities, and the approach taken to life extension for a typical

  6. Effects of fungal pretreatment and steam explosion pretreatment on enzymatic saccharification of plant biomass.

    Science.gov (United States)

    Sawada, T; Nakamura, Y; Kobayashi, F; Kuwahara, M; Watanabe, T

    1995-12-20

    The effects of consecutive treatments by a lignin-degrading fungus Phanerochaete chrysosporium and by steam explosion for the enzymatic saccharification of plant biomass were studied experimentally, and the optimal operational conditions for obtaining the maximum saccharification were evaluated. Beech wood-meal was treated by the fungus for 98 days and then by high steam temperatures of 170-230 degrees C with steaming times of 0-10 min. The treatment of the wood-meal by fungus prior to steam explosion enhanced the saccharification of wood-meal. The treated wood-meal was separated into holo-cellulose, water soluble material, methanol soluble lignin, and Klason lignin. The saccharification decreased linearly with the increase in the amount of Klason lignin. It was estimated by the equation for the saccharification of exploded wood-meal expressed as a function of steam temperature and steaming time that the maximum saccharification of wood-meal was obtained by consecutive treatments such as fungal treatment for 28 days and then steam explosion at a steam temperature of 215 degrees C and a steaming time of 6.5 min. (c) 1995 John Wiley & Sons, Inc.

  7. Gas--steam turbine combined cycle power plants

    Energy Technology Data Exchange (ETDEWEB)

    Christian, J.E.

    1978-10-01

    The purpose of this technology evaluation is to provide performance and cost characteristics of the combined gas and steam turbine, cycle system applied to an Integrated Community Energy System (ICES). To date, most of the applications of combined cycles have been for electric power generation only. The basic gas--steam turbine combined cycle consists of: (1) a gas turbine-generator set, (2) a waste-heat recovery boiler in the gas turbine exhaust stream designed to produce steam, and (3) a steam turbine acting as a bottoming cycle. Because modification of the standard steam portion of the combined cycle would be necessary to recover waste heat at a useful temperature (> 212/sup 0/F), some sacrifice in the potential conversion efficiency is necessary at this temperature. The total energy efficiency ((electric power + recovered waste heat) divided by input fuel energy) varies from about 65 to 73% at full load to 34 to 49% at 20% rated electric power output. Two major factors that must be considered when installing a gas--steam turbine combines cycle are: the realiability of the gas turbine portion of the cycle, and the availability of liquid and gas fuels or the feasibility of hooking up with a coal gasification/liquefaction process.

  8. Modeling a Helical-coil Steam Generator in RELAP5-3D for the Next Generation Nuclear Plant

    Energy Technology Data Exchange (ETDEWEB)

    Nathan V. Hoffer; Piyush Sabharwall; Nolan A. Anderson

    2011-01-01

    Options for the primary heat transport loop heat exchangers for the Next Generation Nuclear Plant are currently being evaluated. A helical-coil steam generator is one heat exchanger design under consideration. Safety is an integral part of the helical-coil steam generator evaluation. Transient analysis plays a key role in evaluation of the steam generators safety. Using RELAP5-3D to model the helical-coil steam generator, a loss of pressure in the primary side of the steam generator is simulated. This report details the development of the steam generator model, the loss of pressure transient, and the response of the steam generator primary and secondary systems to the loss of primary pressure. Back ground on High Temperature Gas-cooled reactors, steam generators, the Next Generation Nuclear Plant is provided to increase the readers understanding of the material presented.

  9. Effect of Low Pressure End Conditions on Steam Power Plant Performance

    Directory of Open Access Journals (Sweden)

    Ali Syed Haider

    2014-07-01

    Full Text Available Most of the electricity produced throughout the world today is from steam power plants and improving the performance of power plants is crucial to minimize the greenhouse gas emissions and fuel consumption. Energy efficiency of a thermal power plant strongly depends on its boiler-condenser operating conditions. The low pressure end conditions of a condenser have influence on the power output, steam consumption and efficiency of a plant. Hence, the objective this paper is to study the effect of the low pressure end conditions on a steam power plant performance. For the study each component was modelled thermodynamically. Simulation was done and the results showed that performance of the condenser is highly a function of its pressure which in turn depends on the flow rate and temperature of the cooling water. Furthermore, when the condenser pressure increases both net power output and plant efficiency decrease whereas the steam consumption increases. The results can be used to run a steam power cycle at optimum conditions.

  10. High performance steam development. Final report, Phase No. 3: 1500{degree}F steam plant for industrial cogeneration prototype development tests

    Energy Technology Data Exchange (ETDEWEB)

    Duffy, T.; Schneider, P.

    1996-01-01

    As a key part of DOE`s and industry`s R&D efforts to improve the efficiency, cost, and emissions of power generation, a prototype High Performance Steam System (HPSS) has been designed, built, and demonstrated. The world`s highest temperature ASME Section I coded power plant successfully completed over 100 hours of development tests at 1500{degrees}F and 1500 psig on a 56,000 pound per hour steam generator, control valve and topping turbine at an output power of 5500 hp. This development advances the HPSS to 400{degrees}F higher steam temperature than the current best technology being installed around the world. Higher cycle temperatures produce higher conversion efficiencies and since steam is used to produce the large majority of the world`s power, the authors expect HPSS developments will have a major impact on electric power production and cogeneration in the twenty-first century. Coal fueled steam plants now produce the majority of the United States electric power. Cogeneration and reduced costs and availability of natural gas have now made gas turbines using Heat Recovery Steam Generators (HRSG`s) and combined cycles for cogeneration and power generation the lowest cost producer of electric power in the United States. These gas fueled combined cycles also have major benefits in reducing emissions while reducing the cost of electricity. Development of HPSS technology can significantly improve the efficiency of cogeneration, steam plants, and combined cycles. Figure 2 is a TS diagram that shows the HPSS has twice the energy available from each pound of steam when expanding from 1500{degrees}F and 1500 psia to 165 psia (150 psig, a common cogeneration process steam pressure). This report describes the prototype component and system design, and results of the 100-hour laboratory tests. The next phase of the program consists of building up the steam turbine into a generator set, and installing the power plant at an industrial site for extended operation.

  11. Exergo-Economic Fuel-Impact Analysis for Steam Turbines Sections in Power Plants

    Directory of Open Access Journals (Sweden)

    Javier Royo

    2003-09-01

    Full Text Available In this paper exergoeconomic fuel-impact models for steam turbines in power plants are proposed. They are applied to calculate the impact on the steam cycle when malfunctions are occurring during the operation of steam turbine sections. Concepts such as the exergetic consumption and the dissipation temperature are used to understand the proposed fuel-impact analysis. In order to validate these fuel-impact methods, well-known procedures, to simulate on- and off-design conditions of a steam power cycle, are used as references. Three different methods a ASME PTC-6, b existing fuel-impact formula, and c proposed exergoeconomic Fuel–Impact formulation, are compared with respect to the simulator results. The proposed models allow evaluating fuel-impact cost with more accurate results than conventional procedures. An example of a 158 MW conventional power plant is presented herein. The malfunction costs occurring in the steam turbines are inferred from the results. One perspective of this analysis is to establish an on-line monitoring system into power plants that permits to opportunely detect steam turbine malfunctions, without simulators.

  12. Steam/fuel system optimization report: 6000-tpd SRC-I Demonstration Plant

    Energy Technology Data Exchange (ETDEWEB)

    Vakil, T.D.

    1983-07-01

    The design and configuration of the steam and fuel system for the 6000-ton-per-day (tpd) SRC-I Demonstration plant have been optimized, based on requirements for each area of the plant that were detailed in Area Baseline Designs of December 1982. The system was optimized primarily for the two most likely modes of plant operation, that is, when the expanded-bed hydrocracker (EBH) is operating at either high or low conversion, with all other units operating. However, the design, as such, is also operable under four other anticipated operating modes. The plant is self-sufficient in fuel except when the coker/calciner unit is not operating; then the required fuel oil import ranges from 80 to 125 MM Btu/h, lower heating value (LHV). The system affords stable operation under varying fuel gas availability and is reliable, flexible, and efficient. The optimization was based on maximizing overall efficiency of the steam system. The system was optimized to operate at five different steam-pressure levels, which are justifiable based on the plant's team requirements for process, heat duty, and power. All identified critical equipment drives will be run by steam turbines. Also part of the optimization was elimination of the steam evaporator in the wastewater treatment area. This minimized the impact on the steam system of operating in either the discharge of zero-discharge mode; the steam system remains essentially the same for either mode. Any further optimization efforts should be based on overall cost-effectiveness.

  13. Steam explosion and its combinatorial pretreatment refining technology of plant biomass to bio-based products.

    Science.gov (United States)

    Chen, Hong-Zhang; Liu, Zhi-Hua

    2015-06-01

    Pretreatment is a key unit operation affecting the refinery efficiency of plant biomass. However, the poor efficiency of pretreatment and the lack of basic theory are the main challenges to the industrial implementation of the plant biomass refinery. The purpose of this work is to review steam explosion and its combinatorial pretreatment as a means of overcoming the intrinsic characteristics of plant biomass, including recalcitrance, heterogeneity, multi-composition, and diversity. The main advantages of the selective use of steam explosion and other combinatorial pretreatments across the diversity of raw materials are introduced. Combinatorial pretreatment integrated with other unit operations is proposed as a means to exploit the high-efficiency production of bio-based products from plant biomass. Finally, several pilot- and demonstration-scale operations of the plant biomass refinery are described. Based on the principle of selective function and structure fractionation, and multi-level and directional composition conversion, an integrated process with the combinatorial pretreatments of steam explosion and other pretreatments as the core should be feasible and conform to the plant biomass refinery concept. Combinatorial pretreatments of steam explosion and other pretreatments should be further exploited based on the type and intrinsic characteristics of the plant biomass used, the bio-based products to be made, and the complementarity of the processes.

  14. Use of Cooling Thermal Storage as a Heat Sink for Steam Power Plant

    Science.gov (United States)

    Hegazy, Ahmed Sabry

    In the present paper, a system is proposed for improving the performance of steam power plant with air-cooled condenser during peak loads. In this system, the power plant comprises two steam turbines, and the air-cooled condenser is replaced by two condensers. The first one is air-cooled (dry) and used for condensing the exhaust steam of the first turbine, while the second is water-cooled and serves to condense the steam outlet of the second turbine. The warm cooling water exiting the wet condenser is pumped to a cooling storage container, where it is cooled and re-circulated to the wet condenser. Cooling is produced by a refrigeration machine driven by the extra electric power generated by the two turbines during the time of the off-peak-loads (low electricity rates). Simple energy analyses have been developed to predict the energy characteristics of this system. The results of this paper showed that the proposed system leads to improving the plant power output at peak-loads. About 6, 16, 24 and 33% increase in generated plant power can be achieved at peak-loads (high electricity rates) when the ambient temperature is 20, 30, 40 and 50°C respectively, and the whole steam exiting both turbines is cooled in a wet condenser to a design temperature of 20°C. The results showed also that choice of the capacity of each turbine is essentially affected by the quality of the refrigeration machine and ambient temperature.

  15. Plant Characteristics of an Integrated Solid Oxide Fuel Cell Cycle and a Steam Cycle

    DEFF Research Database (Denmark)

    Rokni, Masoud

    2010-01-01

    Plant characteristics of a system containing a solid oxide fuel cell (SOFC) cycle on the top of a Rankine cycle were investigated. Natural gas (NG) was used as the fuel for the plant. A desulfurization reactor removes the sulfur content in the fuel, while a pre-reformer broke down the heavier...... hydrocarbons in an adiabatic steam reformer (ASR). The pre-treated fuel then entered to the anode side of the SOFC. The remaining fuels after the SOFC stacks entered a catalytic burner for further combusting. The burned gases from the burner were then used to produce steam for the Rankine cycle in a heat...... recovery steam generator (HRSG). The remaining energy of the off-gases was recycled back to the topping cycle for further utilization. Several parameter studies were carried out to investigate the sensitivity of the suggested plant. It was shown that the operation temperature of the desulfurization unit...

  16. Starting up of new steam generator of N4 1450 MWE plants

    Energy Technology Data Exchange (ETDEWEB)

    Bussy, B. [EDF, Villeurbanne Cedex (France); Dague, G.; Slama, G. [Framatome, Paris-le-Defense (France)

    1998-07-01

    The first N4 plant, CHOOZ B1, was commissioned in 1997. This plant of 1450 MWe capacity is equipped with four steam generators of a new design fitted with an axial economiser. The axial economiser principle essentially consists in directing all the feedwater to the cold leg of the tube bundle and about 90% of the recirculated water to the hot leg. A double wrapper alone, the downcomer allows cold water to enter tube bundle as in a boiler-type steam generator andprevents excessive vibration due to cross flow. The main result of this design is to enhance the heat exchange efficiency between the primary and the secondary sides and to increase the steam pressure as compared to a boiler steam generator having the same heat exchange area. As it is the common practice in France for the first plant unit of a new model, one of the four steam generators has been specifically instrumented in order to assess its actual operating characteristics and verify their consistency with the predicted values resulting from the design studies and from the qualification tests. The test programme and the dedicated instrumentation allowed measurement of essential S.G. thermal hydraulics parameters (saturation pressure, flow velocities, pressure drops, circulation ratios, temperature distribution,...) and assessment of vibratory behaviour of tube bundle. The results are in agreement with the tests carried out in the course of the steam generator development and qualification programme, notably a few years ago on the large 25 MWth MEGEVE test facility. They confirm adequacy of the axial economiser design. The paper describes successively: the specificities of the new steam generator design; the instrumentation and the test programme; and the main results obtained from the numerous tests performed during plant start-up. (author)

  17. Integration of a Gas Fired Steam Power Plant with a Total Site Utility Using a New Cogeneration Targeting Procedure

    Institute of Scientific and Technical Information of China (English)

    Sajad Khamis Abadi; Mohammad Hasan Khoshgoftar Manesh; Marc A.Rosen; Majid Amidpour; Mohammad Hosein Hamedi

    2014-01-01

    A steam power plant can work as a dual purpose plant for simultaneous production of steam and elec-trical power. In this paper we seek the optimum integration of a steam power plant as a source and a site utility sys-tem as a sink of steam and power. Estimation for the cogeneration potential prior to the design of a central utility system for site utility systems is vital to the targets for site fuel demand as well as heat and power production. In this regard, a new cogeneration targeting procedure is proposed for integration of a steam power plant and a site utility consisting of a process plant. The new methodology seeks the optimal integration based on a new cogenera-tion targeting scheme. In addition, a modified site utility grand composite curve (SUGCC) diagram is proposed and compared to the original SUGCC. A gas fired steam power plant and a process site utility is considered in a case study. The applicability of the developed procedure is tested against other design methods (STAR® and Thermoflex software) through a case study. The proposed method gives comparable results, and the targeting method is used for optimal integration of steam levels. Identifying optimal conditions of steam levels for integration is important in the design of utility systems, as the selection of steam levels in a steam power plant and site utility for integration greatly influences the potential for cogeneration and energy recovery. The integration of steam levels of the steam power plant and the site utility system in the case study demonstrates the usefulness of the method for reducing the overall energy consumption for the site.

  18. Steam generators and waste heat boilers for process and plant engineers

    CERN Document Server

    Ganapathy, V

    2014-01-01

    Incorporates Worked-Out Real-World ProblemsSteam Generators and Waste Heat Boilers: For Process and Plant Engineers focuses on the thermal design and performance aspects of steam generators, HRSGs and fire tube, water tube waste heat boilers including air heaters, and condensing economizers. Over 120 real-life problems are fully worked out which will help plant engineers in evaluating new boilers or making modifications to existing boiler components without assistance from boiler suppliers. The book examines recent trends and developments in boiler design and technology and presents novel idea

  19. IMPACT OF THE COLD END OPERATING CONDITIONS ON ENERGY EFFICIENCY OF THE STEAM POWER PLANTS

    Directory of Open Access Journals (Sweden)

    Slobodan Laković

    2010-01-01

    Full Text Available The conventional steam power plant working under the Rankine Cycle and the steam condenser as a heat sink and the steam boiler as a heat source have the same importance for the power plant operating process. Energy efficiency of the coal fired power plant strongly depends on its turbine-condenser system operation mode. For the given thermal power plant configuration, cooling water temperature or/and flow rate change generate alterations in the condenser pressure. Those changes have great influence on the energy efficiency of the plant. This paper focuses on the influence of the cooling water temperature and flow rate on the condenser performance, and thus on the specific heat rate of the coal fired plant and its energy efficiency. Reference plant is working under turbine-follow mode with an open cycle cooling system. Analysis is done using thermodynamic theory, in order to define heat load dependence on the cooling water temperature and flow rate. Having these correlations, for given cooling water temperature it is possible to determine optimal flow rate of the cooling water in order to achieve an optimal condensing pressure, and thus, optimal energy efficiency of the plant. Obtained results could be used as useful guidelines in improving existing power plants performances and also in design of the new power plants.

  20. International water and steam quality standards on thermal power plants at all-volatile treatment

    Science.gov (United States)

    Petrova, T. I.; Orlov, K. A.; Dooley, R. B.

    2016-12-01

    One of the methods for the improvement of reliability and efficiency of the equipment at heat power plants is the decrease in the rate of corrosion of structural materials and sedimentation in water/steam circuit. These processes can be reduced to minimum by using the water with low impurity content and coolant treatment. For many years, water and steam quality standards were developed in various countries (United States, Germany, Japan, etc.) for specific types of equipment. The International Association for the Properties of Water and Steam (IAPWS), which brings together specialists from 21 countries, developed the water and steam quality standards for various types of power equipment based on theoretical studies and long-term operating experience of power equipment. Recently, various water-chemistry conditions are applied on heatpower equipment including conventional boilers and HRSGs with combined cycle power plants (Combined Cycle Power Plants (CCPP)). In paper, the maintenance conditions of water chemistry with ammonia or volatile amine dosing are described: reducing AVT(R), oxidizing AVT(O), and oxygen OT. Each of them is provided by the water and steam quality standards and recommendations are given on their maintenance under various operation conditions. It is noted that the quality control of heat carrier must be carried out with a particular care on the HPPs with combined cycle gas turbine units, where frequent starts and halts are performed.

  1. Disposal of Steam Generators from Decommissioning of PWR Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Walberg, Mirko; Viermann, Joerg; Beverungen, Martin [GNS Gesellschaft fuer Nuklear-Service mbH, Hollestrasse 7A, 45127 Essen (Germany); Kemp, Lutz [Kernkraftwerk Stade GmbH and Co.oHG, Bassenflether Chaussee, 21683 Stade (Germany); Lindstroem, Anders [Studsvik Nuclear AB, SE-611 82 Nykoeping (Sweden)

    2008-07-01

    Amongst other materials remarkable amounts of radioactively contaminated or activated scrap are generated from the dismantling of Nuclear Power Plants. These scrap materials include contaminated pipework, fittings, pumps, the reactor pressure vessel and other large components, most of them are heat exchangers. Taking into account all commercial and technical aspects an external processing and subsequent recycling of the material might be an advantageous option for many of these components. The disposal of steam generators makes up an especially challenging task because of their measures, their weight and compared to other heat exchangers high radioactive inventory. Based on its experiences from many years of disposal of smaller components of NPP still in operation or under decommissioning GNS and Studsvik Nuclear developed a concept for disposal of steam generators, also involving experiences made in Sweden. The concept comprises transport preparations and necessary supporting documents, the complete logistics chain, steam generator treatment and the processing of arising residues and materials not suitable for recycling. The first components to be prepared, shipped and treated according to this concept were four steam generators from the decommissioning of the German NPP Stade which were removed from the plant and shipped to the processing facility during the third quarter of 2007. Although the plant had undergone a full system decontamination, due to the remaining contamination in a number of plugged tubes the steam generators had to be qualified as industrial packages, type 2 (IP-2 packages), and according to a special requirement of the German Federal Office for Radiation Protection a license for a shipment under special arrangement had to be applied for. The presentation gives an overview of the calculations and evidences required within the course of the IP-2 qualification, additional requirements of the competent authorities during the licensing procedure as

  2. Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators

    OpenAIRE

    Akın Avşaroğlu; Suphi URAL

    2017-01-01

    The purpose of this study is to Reducing and Analysing of Flow Accelerated Corrosion in Thermal Plant Heat Recovery Steam Generators. All these studies have been performed in a new and 16 year-old established Combined Cycle Power Plants in Turkey. Corrosion cases have been investigated due to Mechanical Outage Reports at Power Plant in 2011-2015. Flow Accelerated Corrosion study has been based on specific zone related with Economizer Low Pressure connection pipings. It was issued a performanc...

  3. Long term steam oxidation of TP 347H FG in power plants

    DEFF Research Database (Denmark)

    Hansson, Anette Nørgaard; Korcakova, Leona; Hald, John

    2005-01-01

    The long term oxidation behaviour of TP 347H FG at ultra supercritical steam conditions was assessed by exposing the steel in test superheater loops in a Danish coal-fired power plant. The steamside oxide layer was investigated with scanning electron microscopy and energy dispersive Xray diffract......The long term oxidation behaviour of TP 347H FG at ultra supercritical steam conditions was assessed by exposing the steel in test superheater loops in a Danish coal-fired power plant. The steamside oxide layer was investigated with scanning electron microscopy and energy dispersive Xray...... diffraction in order to reveal the effect of oxidation time and temperature on the microstructure. A double layered oxide formed during steam oxidation. The morphology of the inner Cr-containing layer was influenced by the oxidation temperature. At temperatures below 585 degrees C, it consisted of regions...

  4. A high-temperature gas-and-steam turbine plant operating on combined fuel

    Science.gov (United States)

    Klimenko, A. V.; Milman, O. O.; Shifrin, B. A.

    2015-11-01

    A high-temperature gas-steam turbine plant (GSTP) for ultrasupercritical steam conditions is proposed based on an analysis of prospects for the development of power engineering around the world and in Russia up to 2040. The performance indicators of a GSTP using steam from a coal-fired boiler with a temperature of 560-620°C with its superheating to 1000-1500°C by firing natural gas with oxygen in a mixingtype steam superheater are analyzed. The thermal process circuit and design of a GSTP for a capacity of 25 MW with the high- and intermediate-pressure high-temperature parts with the total efficiency equal to 51.7% and the natural gas utilization efficiency equal to 64-68% are developed. The principles of designing and the design arrangement of a 300 MW GSTP are developed. The effect of economic parameters (the level and ratio of prices for solid fuel and gas, and capital investments) on the net cost of electric energy is determined. The net cost of electric energy produced by the GSTP is lower than that produced by modern combined-cycle power plants in a wide variation range of these parameters. The components of a high-temperature GSTP the development of which determines the main features of such installations are pointed out: a chamber for combusting natural gas and oxygen in a mixture with steam, a vacuum device for condensing steam with a high content of nondensables, and a control system. The possibility of using domestically available gas turbine technologies for developing the GSTP's intermediate-pressure high-temperature part is pointed out. In regard of its environmental characteristics, the GSTP is more advantageous as compared with modern condensing power plants: it allows a flow of concentrated carbon dioxide to be obtained at its outlet, which can be reclaimed; in addition, this plant requires half as much consumption of fresh water.

  5. Exergy Analysis of a Subcritical Reheat Steam Power Plant with Regression Modeling and Optimization

    Directory of Open Access Journals (Sweden)

    MUHIB ALI RAJPER

    2016-07-01

    Full Text Available In this paper, exergy analysis of a 210 MW SPP (Steam Power Plant is performed. Firstly, the plant is modeled and validated, followed by a parametric study to show the effects of various operating parameters on the performance parameters. The net power output, energy efficiency, and exergy efficiency are taken as the performance parameters, while the condenser pressure, main steam pressure, bled steam pressures, main steam temperature, and reheat steam temperature isnominated as the operating parameters. Moreover, multiple polynomial regression models are developed to correlate each performance parameter with the operating parameters. The performance is then optimizedby using Direct-searchmethod. According to the results, the net power output, energy efficiency, and exergy efficiency are calculated as 186.5 MW, 31.37 and 30.41%, respectively under normal operating conditions as a base case. The condenser is a major contributor towards the energy loss, followed by the boiler, whereas the highest irreversibilities occur in the boiler and turbine. According to the parametric study, variation in the operating parameters greatly influences the performance parameters. The regression models have appeared to be a good estimator of the performance parameters. The optimum net power output, energy efficiency and exergy efficiency are obtained as 227.6 MW, 37.4 and 36.4, respectively, which have been calculated along with optimal values of selected operating parameters.

  6. GRAPHICAL REPRESENTATIONS OF 1991 STEAM-ELECTRIC POWER PLANT OPERATION AND AIR EMISSIONS DATA

    Science.gov (United States)

    The report provides graphical representations of data derived from the U.S. Department of Energy's (DOE's) Energy Information Administration, s Form EIA-767 (Steam Electric Plant Operation and Design Report). or more than 10 years, EIA has collected monthly boiler level data from...

  7. Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives Energy Assessment

    Energy Technology Data Exchange (ETDEWEB)

    None

    2008-07-01

    The J.R. Simplot Company's Don Plant in Pocatello, Idaho, optimized boiler operation, improved condensate recovery, and fixed steam traps and leaks for a simple payback of 6.5 months. Results are being shared with other Simplot facilities and other recommendations identified during the assessment are under consideration.

  8. EPA Announces National Limits to Reduce Toxic Pollutants Discharged into Waterways by Steam Electric Power Plants

    Science.gov (United States)

    WASHINGTON - The U.S. Environmental Protection Agency (EPA) today finalized a rule that will reduce the discharge of toxic pollutants into America's waterways from steam electric power plants by 1.4 billion pounds annually, as well as reduce water w

  9. Review of the coal-fired, over-supercritical and ultra-supercritical steam power plants

    Science.gov (United States)

    Tumanovskii, A. G.; Shvarts, A. L.; Somova, E. V.; Verbovetskii, E. Kh.; Avrutskii, G. D.; Ermakova, S. V.; Kalugin, R. N.; Lazarev, M. V.

    2017-02-01

    The article presents a review of developments of modern high-capacity coal-fired over-supercritical (OSC) and ultra-supercritical (USC) steam power plants and their implementation. The basic engineering solutions are reported that ensure the reliability, economic performance, and low atmospheric pollution levels. The net efficiency of the power plants is increased by optimizing the heat balance, improving the primary and auxiliary equipment, and, which is the main thing, by increasing the throttle conditions. As a result of the enhanced efficiency, emissions of hazardous substances into the atmosphere, including carbon dioxide, the "greenhouse" gas, are reduced. To date, the exhaust steam conditions in the world power industry are p 0 ≈ 30 MPa and t 0 = 610/620°C. The efficiency of such power plants reaches 47%. The OSC plants are being operated in Germany, Denmark, Japan, China, and Korea; pilot plants are being developed in Russia. Currently, a project of a power plant for the ultra-supercritical steam conditions p 0 ≈ 35 MPa and t 0 = 700/720°C with efficiency of approximately 50% is being studied in the EU within the framework of the Thermie AD700 program, project AD 700PF. Investigations in this field have also been launched in the United States, Japan, and China. Engineering solutions are also being sought in Russia by the All-Russia Thermal Engineering Research Institute (VTI) and the Moscow Power Engineering Institute. The stated steam parameter level necessitates application of new materials, namely, nickel-base alloys. Taking into consideration high costs of nickel-base alloys and the absence in Russia of technologies for their production and manufacture of products from these materials for steam-turbine power plants, the development of power plants for steam parameters of 32 MPa and 650/650°C should be considered to be the first stage in creating the USC plants as, to achieve the above parameters, no expensive alloys are require. To develop and

  10. Combined Refrigeration Cycle for Thermal Power Plant Using Low Grade Waste Steam

    Directory of Open Access Journals (Sweden)

    Satish Maurya*,

    2014-02-01

    Full Text Available Now a days, In most of the thermal power plant, where low-pressure steam is being exhausted to the atmosphere as a waste steam. This waste heat could be use to operate many small preheating or cooling equipments or small scale plants. There are many refrigeration systems present for refrigeration and air condition purpose. Such as air refrigeration, vapour compression, vapour absorption etc. In this paper we have presented the concept of combined vapour absorption and vapour compression refrigeration system. We present about the idea discuss here that how a vapour absorption and vapour compression can be used together as one complete working refrigeration plant. By using such concept of refrigeration we can improve the co-efficient of performance of whole plant by minimizing the input. We can also named the system as waste heat recovery refrigeration system.

  11. Experiences with Direct Steam Generation at the Kanchanaburi Solar Thermal Power Plant

    OpenAIRE

    Krüger, Dirk; Krüger, Joachim; Pandian, Yuvaraj; O'Connell, Bryan; Feldhoff, Jan Fabian; Karthikeyan, Ramkumar; Hempel, Sören; Muniasamy, Karthik; Hirsch, Tobias; Eickhoff, Martin; Hennecke, Klaus

    2012-01-01

    In 2011 the parabolic trough power plant TSE1 has started operation in Thailand. As a novelty it uses the direct steam generation (DSG) process, evaporating and super heating water and steam directly in the solar field. During the commissioning phase and first months of operation the start-up procedure has been optimised for the solar field and turbine system resulting in a reduced start-up time. The DSG process can be controlled well in the evaporator and super heater section securing a safe...

  12. Steam plant for producing drinking water from seawater. Dampfkraftanlage zur Erzeugung von Trinkwasser aus Meerwasser

    Energy Technology Data Exchange (ETDEWEB)

    Kuenstle, K.; Lezuo, A.

    1984-04-05

    In order to be able to match a seawater desalination plant to different conditions of the electrical mains supply while maintaining the overall efficiency of the plant, the vapour compressor is driven by a steam turbine, which is coupled via an electric generator or motor to the electrical mains supply; also heat exchangers for cooling the brine and/or the destillate are situated in the seawater feedpipe to a bypass.

  13. Reducing And Analysizing of Flow Accelerated Corrosion at Thermal Power Plant, Heat Recovery Steam Generators

    Directory of Open Access Journals (Sweden)

    Akın Avşaroğlu

    2017-01-01

    Full Text Available The purpose of this study is to Reducing and Analysing of Flow Accelerated Corrosion in Thermal Plant Heat Recovery Steam Generators. All these studies have been performed in a new and 16 year-old established Combined Cycle Power Plants in Turkey. Corrosion cases have been investigated due to Mechanical Outage Reports at Power Plant in 2011-2015. Flow Accelerated Corrosion study has been based on specific zone related with Economizer Low Pressure connection pipings. It was issued a performance report. Results and lessons learnt from these studies will be used as a preventive action manner in all similar Plants.

  14. Evaluation of Hybrid Power Plants using Biomass, Photovoltaics and Steam Electrolysis for Hydrogen and Power Generation

    Science.gov (United States)

    Petrakopoulou, F.; Sanz, J.

    2014-12-01

    Steam electrolysis is a promising process of large-scale centralized hydrogen production, while it is also considered an excellent option for the efficient use of renewable solar and geothermal energy resources. This work studies the operation of an intermediate temperature steam electrolyzer (ITSE) and its incorporation into hybrid power plants that include biomass combustion and photovoltaic panels (PV). The plants generate both electricity and hydrogen. The reference -biomass- power plant and four variations of a hybrid biomass-PV incorporating the reference biomass plant and the ITSE are simulated and evaluated using exergetic analysis. The variations of the hybrid power plants are associated with (1) the air recirculation from the electrolyzer to the biomass power plant, (2) the elimination of the sweep gas of the electrolyzer, (3) the replacement of two electric heaters with gas/gas heat exchangers, and (4) the replacement two heat exchangers of the reference electrolyzer unit with one heat exchanger that uses steam from the biomass power plant. In all cases, 60% of the electricity required in the electrolyzer is covered by the biomass plant and 40% by the photovoltaic panels. When comparing the hybrid plants with the reference biomass power plant that has identical operation and structure as that incorporated in the hybrid plants, we observe an efficiency decrease that varies depending on the scenario. The efficiency decrease stems mainly from the low effectiveness of the photovoltaic panels (14.4%). When comparing the hybrid scenarios, we see that the elimination of the sweep gas decreases the power consumption due to the elimination of the compressor used to cover the pressure losses of the filter, the heat exchangers and the electrolyzer. Nevertheless, if the sweep gas is used to preheat the air entering the boiler of the biomass power plant, the efficiency of the plant increases. When replacing the electric heaters with gas-gas heat exchangers, the

  15. The Life Assessment of Steam Turbine Rotors for Fossil Power Plants

    Science.gov (United States)

    Chang, Sungho; Song, Geewook; Kim, Bumshin; Hyun, Jungseb; Ha, Jeongsoo

    The operational mode of thermal power plants has been changed from base load to duty cycle. From the changeover, fossil power plants cannot avoid frequent thermal transient states, for example, start up and stop, which results in thermal fatigue damage at the heavy section components. The rotor is the highest capital cost component in a steam turbine and requires long outage for replacing with a new one. For an optimized power plant operational life, inspection management of the rotor is necessary. It is known in general that the start-up and shutdown operations greatly affect the steam turbine life. The start-up operational condition is especially severe because of the rapid temperature and rotational speed increase, which causes damage and reduction of life of the main components life of the steam turbine. The start-up stress of a rotor which is directly related to life is composed of thermal and rotational stresses. The thermal stress is due to the variation of steam flow temperature and rotational stress is due to the rotational speed of the turbine. In this paper, the analysis method for the start-up stress of a rotor is proposed, which considers simultaneously temperature and rotational speed transition, and includes a case study regarding a 500MW fossil power plant steam turbine rotor. Also, the method of quantitative damage estimation for fatigue-creep damage to operational conditions, is described. The method can be applied to find weak points for fatigue-creep damage. Using the method, total life consumption can be obtained, and can be also be used for determining future operational modes and life extension of old fossil power units.

  16. On Energy Diagnosis of Steam Power Plants: A Comparison among Three Global Losses Formulations

    Directory of Open Access Journals (Sweden)

    Rodolfo Taccani

    2002-12-01

    Full Text Available

    The objectives of energy systems diagnosis are: i identifying components responsible for highest losses increments in comparison with design conditions, ii quantifying energy-efficiency recovery when design conditions are restored in a particular system component. In this paper the energy diagnosis of an existing steam power plant is faced on the basis of three different formulae expressing global losses.

    A simulation model of a real 320 MW steam power plant has been implemented with a commercial modular energy systems simulation software (Aspen+. The functional decay of different components of the plant has been simulated using the model. The results show that the components actually responsible for the additional power losses can be identified and the effect of restoring design conditions can be quantified in most cases with sufficient approximation by using the General Formula for the Efficiency or the Lost work Impact Formula (developed in the ambit of thermoeconomics.

  17. Sensory characteristics of antioxidant extracts from Uruguayan native plants: influence of deodorization by steam distillation.

    Science.gov (United States)

    Miraballes, Marcelo; Gámbaro, Adriana; Ares, Gastón

    2013-12-01

    Polyphenolic-rich antioxidant extracts from native plants have potential applications as ingredients in functional foods; however, their intense characteristic flavour is a major limitation to their application. In this context, the aim of the present work was to evaluate the influence of steam distillation on the sensory and physicochemical characteristics of extracts of five native Uruguayan plants (Acca sellowiana, Achyrocline satureioides, Aloysia gratisima, Baccharis trimera and Mikania guaco). Aqueous extracts from the five native plants were obtained. Steam distillation was used to produce two types of deodorized extracts: extracts from deodorized leaves and extracts deodorized after the extraction. The extracts were characterized in terms of their total polyphenolic content and antioxidant activity (using 2,2-diphenyl-1-picryl-hydrazyl and 2,2'-azino-bis(3-ethylbenzothiazoline-6-sulfonic acid methods). A trained assessor panel evaluated characteristic odour, characteristic flavour, bitterness and astringency of the extracts. The total polyphenolic content of the extracts ranged from 112.4 to 974.4 mg/100 mL, whereas their antioxidant capacity ranged from 9.6 to 1008.7 mg vitamin C equivalents/100 mL, depending on the type of extract and the method being considered. Steam distillation was effective in reducing the characteristic odour and flavour of the extracts, without causing large changes in their polyphenolic content and antioxidant activity. In general, in terms of sensory characteristics, steam distillation performed on the extracts gave better results than when performed on the leaves; whereas the opposite trend was found for polyphenolic content and antioxidant activity. Results suggested that steam distillation could be a promising low-cost procedure for the production of antioxidant extracts for food products.

  18. Performance analysis of a Kalina cycle for a central receiver solar thermal power plant with direct steam generation

    DEFF Research Database (Denmark)

    Modi, Anish; Haglind, Fredrik

    2014-01-01

    Solar thermal power plants have attracted increasing interest in the past few years - with respect to both the design of the various plant components, and extending the operation hours by employing different types of storage systems. One approach to improve the overall plant efficiency is to use...... without corroding the equipment by using suitable additives with the mixture. The purpose of the study reported here was to investigate if there is any benefit of using a Kalina cycle for a direct steam generation, central receiver solar thermal power plant with high live steam temperature (450 C...... direct steam generation with water/steam as both the heat transfer fluid in the solar receivers and the cycle working fluid. This enables operating the plant with higher turbine inlet temperatures. Available literature suggests that it is feasible to use ammonia-water mixtures at high temperatures...

  19. J.R. Simplot: Burner Upgrade Project Improves Performance and Saves Energy at a Large Food Processing Plant (Steam)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2005-09-01

    This DOE Industrial Program case study describes how the J.R. Simplot Company saved energy and money by increasing the efficiency of the steam system in its potato processing plant in Caldwell, Idaho.

  20. J.R. Simplot: Burner Upgrade Project Improves Performance and Saves Energy at a Large Food Processing Plant (Steam)

    Energy Technology Data Exchange (ETDEWEB)

    None

    2005-09-01

    This DOE Industrial Program case study describes how the J.R. Simplot Company saved energy and money by increasing the efficiency of the steam system in its potato processing plant in Caldwell, Idaho.

  1. Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 11: Advanced steam systems. [energy conversion efficiency for electric power plants using steam

    Science.gov (United States)

    Wolfe, R. W.

    1976-01-01

    A parametric analysis was made of three types of advanced steam power plants that use coal in order to have a comparison of the cost of electricity produced by them a wide range of primary performance variables. Increasing the temperature and pressure of the steam above current industry levels resulted in increased energy costs because the cost of capital increased more than the fuel cost decreased. While the three plant types produced comparable energy cost levels, the pressurized fluidized bed boiler plant produced the lowest energy cost by the small margin of 0.69 mills/MJ (2.5 mills/kWh). It is recommended that this plant be designed in greater detail to determine its cost and performance more accurately than was possible in a broad parametric study and to ascertain problem areas which will require development effort. Also considered are pollution control measures such as scrubbers and separates for particulate emissions from stack gases.

  2. Direct steam generation (DSG) solar thermal power plant in Thailand

    Energy Technology Data Exchange (ETDEWEB)

    Sukchai, Sukruedee; Chramsa-ard, Wisut; Sonsaree, Sorawit; Boonsu, Rungrudee [Naresuan Univ., Phitsanulok (Thailand). School of Renewable Energy Technology; Krueger, Joachim; Pandian, Yuvaraj [Solarlite GmbH, Duckwitz (Germany)

    2012-07-01

    In 2010, the total electricity consumption in Thailand was 149,301 GWh, increased by 10.5% compared with that in the previous year. The economic sector accounting for the highest share of national electricity consumption was the industrial sector, holding a share of 46%; while the household and commercial sectors accounted for a share of 22% and 15% respectively. The electricity is generated from natural gas, coal, oil, hydro, import and other of 72%, 18%, 0.4%, 3%, 4%, and 2% respectively. In the past, the Electricity Generating Authority of Thailand (EGAT) was the sole power producer. Later, the government had formulated a policy promoting the private sector role in the power generation sector in order to encourage competition in the generation business. Currently, it is resulting in a growing number of Very Small Power Producers (VSPP), using renewable energy as main fuel, supplying power to the grid. In this presentation, general background and situation of solar thermal power plant (DSG) in Thailand will be presented. The resource potential which presented by solar map for the central, north and northeast parts of the country is quite clear sky that receive the highest direct normal irradiation of 1,350 - 1,400 kWh/m{sup 2}-year stand for 43% of the total areas of the country. Together with the high direct normal irradiation is received during summer from January to April about 14-17 MJ/m{sup 2}-day. The first of solar thermal power plant in Thailand is presented. Solar energy development that is one of renewable energy promotion program in the nation master plan has been reviewed and discussed to indicate the recommendation. Barriers as educational, technical and financial to promote solar thermal power plant is also presented. From the investigation, this presentation proposes some idea to be the guideline for policy setting, overcome the solar thermal power plant barrier in Thailand. (orig.)

  3. Solar tower power plant using a particle-heated steam generator: Modeling and parametric study

    Science.gov (United States)

    Krüger, Michael; Bartsch, Philipp; Pointner, Harald; Zunft, Stefan

    2016-05-01

    Within the framework of the project HiTExStor II, a system model for the entire power plant consisting of volumetric air receiver, air-sand heat exchanger, sand storage system, steam generator and water-steam cycle was implemented in software "Ebsilon Professional". As a steam generator, the two technologies fluidized bed cooler and moving bed heat exchangers were considered. Physical models for the non-conventional power plant components as air- sand heat exchanger, fluidized bed coolers and moving bed heat exchanger had to be created and implemented in the simulation environment. Using the simulation model for the power plant, the individual components and subassemblies have been designed and the operating parameters were optimized in extensive parametric studies in terms of the essential degrees of freedom. The annual net electricity output for different systems was determined in annual performance calculations at a selected location (Huelva, Spain) using the optimized values for the studied parameters. The solution with moderate regenerative feed water heating has been found the most advantageous. Furthermore, the system with moving bed heat exchanger prevails over the system with fluidized bed cooler due to a 6 % higher net electricity yield.

  4. Summary of the research and development effort on steam plants for electric-utility service

    Energy Technology Data Exchange (ETDEWEB)

    Fraas, A.P.

    1981-06-01

    The development of steam power plants for electric utility service over the past century is reviewed with particular emphasis on the prime problems and their solution. Increases in steam pressure and temperature made possible by developments in metallurgy led to an increase in thermal efficiency by a factor of 8 between 1880 and 1955. Further improvements have not been made because the use of still more expensive alloys is not economically justified, even with the much higher fuel prices of the latter 1970's. In fact, EPA regulations on waste heat and sulfur emissions have led to the use of cooling towers and wet limestone stack gas scrubbers that cause a degradation in plant thermal efficiency. The various possibilities for further improvements in efficiency and their problems are examined. The development of steam power plants in the past has been carried out in sufficiently small steps that the utilities and the equipment manufacturers have been able to assume the financial risk involved; but the fluidized-bed combustion system, which appears to be the most promising area, presents such a large step with major uncertainties that U.S. government financial support of the research and development effort appears to be required. The potential benefits appear to justify the research and development cost many times over.

  5. Development of Multi-Stage Steam Injector for Feedwater Heaters in Simplified Nuclear Power Plant

    Science.gov (United States)

    Narabayashi, Tadashi; Ohmori, Shuichi; Mori, Michitsugu; Asanuma, Yutaka; Iwaki, Chikako

    A steam injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact compact heater to heat up feedwater by using extracted steam from the turbine. To develop high performance compact feedwater heater, it is necessary to quantify the characteristics between physical properties of the flow field. Its performance depends on the phenomena of steam condensation onto the water jet surface and heat transfer in the water jet due to turbulence on to the phase-interface. The analysis was conducted by using CFD code embedded separate two-phase flow models that were confirmed by the experimental data. As the four-stage SI is compact heater, the system is expected to bring about great simplification and materials-saving effects, and high reliability of its operation. Therefore, it is confirmed that the simplification of the power plant by replacing all low-pressure feedwater heaters with the four-stage SI system, having steam extraction pressures equal to those for the existing ABWR system.

  6. Combined heat and power plants with parallel tandem steam turbines; Smaaskalig kraftvaerme med parallellkopplade tandemturbiner

    Energy Technology Data Exchange (ETDEWEB)

    Steinwall, Pontus; Norstroem, Urban; Pettersson, Camilla; Oesterlin, Erik

    2004-12-01

    We investigate the technical and economical conditions for a concept with parallel coupled tandem turbines in small scale combined heat and power plants fired with bio-fuel and waste. Performance and heat production costs at varying electricity prices for the concept with two smaller tandem coupled steam turbines has been compared to the traditional concept with one single multi-staged turbine. Three different types of plants have been investigated: - Bio fuelled CHP plant with thermal capacity of 15 MW{sub th}; - Waste fired CHP plant with thermal capacity of 20 MW{sub th}; - Bio fuelled CHP plant with thermal capacity of 25 MW{sub th}. The simple steam turbines (Curtis turbines) used in the tandem arrangement has an isentropic efficiency of about 49 to 53% compared to the multi-staged steam turbines with isentropic efficiency in the range of 59% to 81%. The lower isentropic efficiency for the single staged turbines is to some extent compensated at partial load when one of the two turbines can be shut down leading to better operational conditions for the one still in operation. For concepts with saturated steam at partial load below 50% the tandem arrangements presents higher electricity efficiency than the conventional single turbine alternative. The difference in annual production of electricity is therefore less than the difference in isentropic efficiency for the two concepts. Production of electricity is between 2% and 42% lower for the tandem arrangements in this study. Investment costs for the turbine island has been calculated for the two turbine concepts and when the costs for turbines, generator, power transmission, condensing system, piping system, buildings, assembling, commissioning and engineering has been added the sum is about the same for the two concepts. For the bio-fuelled plant with thermal capacity of 15 MW{sub th} the turbine island amount to about 10-12 MSEK and about 13-15 MSEK for the waste fired plant with a thermal capacity of 20 MW

  7. Detailed partial load investigation of a thermal energy storage concept for solar thermal power plants with direct steam generation

    Science.gov (United States)

    Seitz, M.; Hübner, S.; Johnson, M.

    2016-05-01

    Direct steam generation enables the implementation of a higher steam temperature for parabolic trough concentrated solar power plants. This leads to much better cycle efficiencies and lower electricity generating costs. For a flexible and more economic operation of such a power plant, it is necessary to develop thermal energy storage systems for the extension of the production time of the power plant. In the case of steam as the heat transfer fluid, it is important to use a storage material that uses latent heat for the storage process. This leads to a minimum of exergy losses during the storage process. In the case of a concentrating solar power plant, superheated steam is needed during the discharging process. This steam cannot be superheated by the latent heat storage system. Therefore, a sensible molten salt storage system is used for this task. In contrast to the state-of-the-art thermal energy storages within the concentrating solar power area of application, a storage system for a direct steam generation plant consists of a latent and a sensible storage part. Thus far, no partial load behaviors of sensible and latent heat storage systems have been analyzed in detail. In this work, an optimized fin structure was developed in order to minimize the costs of the latent heat storage. A complete system simulation of the power plant process, including the solar field, power block and sensible and latent heat energy storage calculates the interaction between the solar field, the power block and the thermal energy storage system.

  8. Thermo-economic study on the implementation of steam turbine concepts for flexible operation on a direct steam generation solar tower power plant

    Science.gov (United States)

    Topel, Monika; Ellakany, Farid; Guédez, Rafael; Genrup, Magnus; Laumert, Björn

    2016-05-01

    Among concentrating solar power technologies, direct steam generation solar tower power plants represent a promising option. These systems eliminate the usage of heat transfer fluids allowing for the power block to be run at greater operating temperatures and therefore further increasing the thermal efficiency of the power cycle. On the other hand, the current state of the art of these systems does not comprise thermal energy storage as there are no currently available and techno-economically feasible storage integration options. This situation makes direct steam generation configurations even more susceptible to the already existing variability of operating conditions due to the fluctuation of the solar supply. In the interest of improving the annual performance and competitiveness of direct steam generation solar tower systems, the present study examines the influence of implementing two flexibility enhancing concepts which control the steam flow to the turbine as a function of the incoming solar irradiation. The proposed concepts were implemented in a reference plant model previously developed by the authors. Then, a multi-objective optimization was carried out in order to understand which configurations of the steam turbine concepts yield reductions of the levelized cost of electricity at a lower investment costs when compared to the reference model. Results show that the implementation of the proposed strategies can enhance the thermo-economic performance of direct steam generation systems by yielding a reduction of up to 9.2% on the levelized cost of electricity, mainly due to allowing 20% increase in the capacity factor, while increasing the investment costs by 7.8%.

  9. MHD-steam thermal power plant electrical stations with zero stack emission

    Energy Technology Data Exchange (ETDEWEB)

    Borghi, C.A.; Botti, M.; Ribani, P.L. [Univ. of Bologna (Italy)

    1994-12-31

    In the present work a system study of a combined cycle MHD-steam thermal power plant electrical station with zero stack emission through recirculation of CO{sub 2}, is presented. The design of the MHD generator of the topper is done by means of a quasi-one-dimensional optimisation model. The thermodynamic of the combustion gas, typical of this cycle, is considered. The technology of the components is conventional. An overall efficiency larger than 41% for power plants with electrical power inputs above 600 MWe, are obtained.

  10. Thermal analysis of heat and power plant with high temperature reactor and intermediate steam cycle

    Directory of Open Access Journals (Sweden)

    Fic Adam

    2015-03-01

    Full Text Available Thermal analysis of a heat and power plant with a high temperature gas cooled nuclear reactor is presented. The main aim of the considered system is to supply a technological process with the heat at suitably high temperature level. The considered unit is also used to produce electricity. The high temperature helium cooled nuclear reactor is the primary heat source in the system, which consists of: the reactor cooling cycle, the steam cycle and the gas heat pump cycle. Helium used as a carrier in the first cycle (classic Brayton cycle, which includes the reactor, delivers heat in a steam generator to produce superheated steam with required parameters of the intermediate cycle. The intermediate cycle is provided to transport energy from the reactor installation to the process installation requiring a high temperature heat. The distance between reactor and the process installation is assumed short and negligable, or alternatively equal to 1 km in the analysis. The system is also equipped with a high temperature argon heat pump to obtain the temperature level of a heat carrier required by a high temperature process. Thus, the steam of the intermediate cycle supplies a lower heat exchanger of the heat pump, a process heat exchanger at the medium temperature level and a classical steam turbine system (Rankine cycle. The main purpose of the research was to evaluate the effectiveness of the system considered and to assess whether such a three cycle cogeneration system is reasonable. Multivariant calculations have been carried out employing the developed mathematical model. The results have been presented in a form of the energy efficiency and exergy efficiency of the system as a function of the temperature drop in the high temperature process heat exchanger and the reactor pressure.

  11. Exergy analysis of boiler of the steam power plant : case study in Iran

    Energy Technology Data Exchange (ETDEWEB)

    Gorji, M.; Ebrahimian, V. [Mazandaran Univ., Babol (Iran, Islamic Republic of). Dept. of Mechanical Engineering

    2006-07-01

    An exergy analysis was conducted to investigate the efficiency of a power plant in Iran. The plant consisted of 4 steam cycle units and 3 turbines of varying pressures using both natural gas and diesel fuel scenarios. The boiler had natural circulation with a 3-staged superheater and 2-stage reheaters and economizers. Energy and exergy balance equations were used to calculate efficiencies. The analysis showed that the total exergy efficiency of the plant was 36.1 per cent for the natural gas scenario and 35.5 per cent for the diesel fuel scenario. Among the main elements of the plant cycle, the highest exergy losses occurred with the boiler. Internal losses of the boiler included heat transfer, combustion, and friction losses, which were estimated at 362899 kW for the natural gas scenario and 411127 MW for the diesel fuel scenario. Exergy losses were primarily due to the exiting of hot gases from the chimney. Exergy losses caused by heat transfer were greater than the exergy losses of the combustion process. The exergy analysis of the boiler elements showed that the reheater had the lowest exergy efficiency and that the evaporator had the highest exergy losses. Results suggested that natural gas was more efficient than diesel fuel for producing superheater vapor in the boiler. It was concluded that the simulation can be used for steam power plants using both natural gas and diesel fuel. 13 refs., 5 tabs., 12 figs.

  12. Suppressed ion chromatography for monitoring chemical impurities in steam for geothermal power plants.

    Science.gov (United States)

    Santoyo, E; Verma, S P; Sandoval, F; Aparicio, A; García, R

    2002-03-08

    A suppressed ion chromatography (IC) technique has been evaluated as a chemical monitoring tool for detecting major anions (F-, Cl-, NO3- and SO4(2-)) of condensed steam in geothermal power plants. It is shown that the suppressed IC technique provides a suitable means for preventing possible damage to generating equipment in the geothermal industry. An electrical conductivity detector (0.1 microS sensitivity) with an anion-exchange column (IonPac AS4A-SC), a micro-membrane suppressor (AMMS II), and an isocratic high-pressure pump system were successfully used for detecting low concentrations of inorganic anions. Method detection limits for the anions of interest were geothermal steam pipes are also described.

  13. System Identification of a Nonlinear Multivariable Steam Generator Power Plant Using Time Delay and Wavelet Neural Networks

    Directory of Open Access Journals (Sweden)

    Laila Khalilzadeh Ganjali-khani

    2013-01-01

    Full Text Available One of the most effective strategies for steam generator efficiency enhancement is to improve the control system. For such an improvement, it is essential to have an accurate model for the steam generator of power plant. In this paper, an industrial steam generator is considered as a nonlinear multivariable system for identification. An important step in nonlinear system identification is the development of a nonlinear model. In recent years, artificial neural networks have been successfully used for identification of nonlinear systems in many researches. Wavelet neural networks (WNNs also are used as a powerful tool for nonlinear system identification. In this paper we present a time delay neural network model and a WNN model in order to identify an industrial steam generator. Simulation results show the effectiveness of the proposed models in the system identification and demonstrate that the WNN model is more precise to estimate the plant outputs.

  14. Heat flow diagrams with and without a deaerator for steam turbine plants with T-250/300-23.5 turbines

    Science.gov (United States)

    Valamin, A. E.; Kultyshev, A. Yu.; Shibaev, T. L.; Gol'dberg, A. A.; Stepanov, M. Yu.

    2016-11-01

    A T-250/300-240 turbine (currently known as T-250/300-23.5), which is operated at 31 steam turbine plants, is the largest in the world extraction turbine (by the heating extraction load) and one of the largest by the nominal capacity. All steam turbine plants equipped with T-250/300-23.5 turbines of different modifications are operated in large cities of Russia and the neighboring countries covering a significant part of the needs of cities for the electric power and almost fully supplying them with heat power. The design life of a significant part of the operated steam turbine plants of this family is either expired or almost expired. It refers to both the turbine unit (including a turbine and a generator) and the turbine plant equipment. For steam turbine plants equipped with T-250/300-23.5 turbines, which were initially designed and mounted for work with deaerators at electric power stations, the heat flow diagrams with and without a deaerator were compared. The main advantages and disadvantages of each scheme were shown. It was concluded that, for the newly constructed power units with supercritical steam parameters, it is preferable to use the heat flow diagram without a deaerator; for the upgraded blocks, if there are no objective reasons for the removal of a deaerator, it is recommended to keep the existing heat flow diagram of a turbine plant.

  15. Advanced numerical description of the behavior of 700 C steam power plant components

    Energy Technology Data Exchange (ETDEWEB)

    Maile, K. [Materialpruefungsanstalt, Univ. Stuttgart (Germany); Schmidt, K.; Roos, E.; Klenk, A.; Speicher, M.

    2009-07-01

    To make full use of the strength potential of new boiler materials like the new 9-11% Cr steels and nickel based alloys, taking into account their specific stress-strain relaxation behavior, new design methods are required in the design of today's power plants. Highly loaded components are approaching more and more the classical design limits with regard to critical wall thicknesses and the related tolerable thermal gradients, due to planed increases of steam parameters like steam pressure and steam temperature. ''Design by analysis'' can be realized by modern state of the art Numerical Finite Element (FE) simulation codes and in some cases by the use of user defined advanced inelastic material laws. These material laws have to be adjusted to specific material behavior of new boiler materials. To model the strain and stress situation in components under high temperature loading, a constitutive equation based on a Graham-Walles approach is used in this paper. Furthermore essential steps and recommendations to implement experimental data in the user defined subroutines and the subsequent integration of the subroutines in modern FE codes like ABAQUS trademark and ANSYS trademark are given. As an example, the results of FE simulations of components like hollow cylinders and waterwall like components made of Alloy 617 or 9-11% Cr steels are discussed and verified with experimental results. In a last step, the successful application of the developed creep equation will be demonstrated by calculating the creep strains and stress relaxation of a P92 steam header under constant loading. (orig.)

  16. Design and modelling of an innovative three-stage thermal storage system for direct steam generation CSP plants

    Science.gov (United States)

    Garcia, Pierre; Vuillerme, Valéry; Olcese, Marco; El Mourchid, Nadim

    2016-05-01

    Thermal Energy Storage systems (TES) for a Direct Steam Generation (DSG) solar plant feature preferably three stages in series including a latent heat storage module so that steam can be recovered with a limited temperature loss. The storage system designed within the Alsolen Sup project is characterized by an innovative combination of sensible and latent modules. A dynamic model of this three-stage storage has been developed and applied to size the storage system of the Alsolen Sup® plant demonstrator at CEA Cadarache. Results of this simulation show that this promising concept is an efficient way to store heat in DSG solar plants.

  17. Analysis of Possible Application of High-Temperature Nuclear Reactors to Contemporary Large-Output Steam Power Plants on Ships

    Directory of Open Access Journals (Sweden)

    Kowalczyk T.

    2016-04-01

    Full Text Available This paper is aimed at analysis of possible application of helium to cooling high-temperature nuclear reactor to be used for generating steam in contemporary ship steam-turbine power plants of a large output with taking into account in particular variable operational parameters. In the first part of the paper types of contemporary ship power plants are presented. Features of today applied PWR reactors and proposed HTR reactors are discussed. Next, issues of load variability of the ship nuclear power plants, features of the proposed thermal cycles and results of their thermodynamic calculations in variable operational conditions, are presented.

  18. Replacement of outboard main steam isolation valves in a boiling water reactor plant

    Energy Technology Data Exchange (ETDEWEB)

    Schlereth, J.R.; Pennington, D.

    1996-12-01

    Most Boiling Water Reactor plants utilize wye pattern globe valves for main steam isolation valves for both inboard and outboard isolation. These valves have required a high degree of maintenance attention in order to pass the plant local leakage rate testing (LLRT) requirements at each outage. Northern States Power made a decision in 1993 to replace the outboard valves at it`s Monticello plant with double disc gate valves. The replacement of the outboard valves was completed during the fall outage in 1994. During the spring outage in April of 1996 the first LLRT testing was performed with excellent results. This presentation will address the decision process, time requirements and planning necessary to accomplish the task as well as the performance results and cost effectiveness of replacing these components.

  19. Influence of Cycle Air Parameters and Flue Gas Path Aerodynamics on Efficiency of Gas Turbine and Steam Gas Plants

    Directory of Open Access Journals (Sweden)

    A. S. Grinchouk

    2009-01-01

    Full Text Available The paper considers an influence of gas-air path aerodynamic resistance for a gas-turbine plant, barometric pressure, air moisture and outside air temperature on parameters, efficiency and characteristics of electric power plants with gas-turbine and combined-cycle sets. Calculations and analysis have been executed for Alstom GT13E2 gas-turbine which is included in composition of Steam Gas Plant-230 at the Minsk Thermal Power Plant No.3.

  20. Thermo-economic analysis of a solid oxide fuel cell and steam injected gas turbine plant integrated with woodchips gasification

    DEFF Research Database (Denmark)

    Mazzucco, Andrea; Rokni, Masoud

    2014-01-01

    This paper presents a thermo-economic analysis of an integrated biogas-fueled solid oxide fuel cell (SOFC) system for electric power generation. Basic plant layout consists of a gasification plant (GP), an SOFC and a retrofitted steam-injected gas turbine (STIG). Different system configurations...

  1. Optimisation of a Kalina cycle for a central receiver solar thermal power plant with direct steam generation

    DEFF Research Database (Denmark)

    Modi, Anish; Haglind, Fredrik

    2014-01-01

    Central receiver solar thermal power plants are regarded as one of the promising ways to generate electricity in near future. They offer the possibility of using high temperatures and pressures to achieve high efficiencies with standard power cycles. A direct steam generation approach can be used...... for a central receiver solar thermal power plant with direct steam generation. The variation in the cycle performance with respect to the turbine inlet ammonia mass fraction and pressure and a comparison of the initial investment with that of the basic Rankine cycle are also presented. Only high live steam...... for such plants for improved performance. This approach can also be combined with using advanced power cycles like the Kalina cycle, which uses a zeotropic mixture of ammonia and water instead of pure water as the working fluid. This paper presents the optimisation of a particular Kalina cycle layout...

  2. Adjustable control in the steam zone of a steam power plant; Control ajustable de la zona de vapor de una unidad termoelectrica

    Energy Technology Data Exchange (ETDEWEB)

    Alvarez Gallegos, Joaquin; Bourguet Diaz, Rafael Ernesto [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1990-12-31

    A general description is presented of self adjustable control systems, as well as of the design and its application for steam temperature regulation of a steam power plant unit model. The algorithm employed is a controller of minimum variance that ponders the output deviation as well as the control effort. The results are compared with the ones obtained in a conventional control scheme, showing in general a better performance in the conducted experiments. [Espanol] Se presenta una descripcion general de los sistemas de control autoajustable, asi como del diseno y su aplicacion para regular las temperaturas de vapor de un modelo de unidad termoelectrica. El algoritmo utilizado es un controlador de variancia minima que pondera tanto la desviacion de salida como el esfuerzo de control. Los resultados se comparan con los obtenidos en un esquema de control convencional, mostrando en general un mejor desempeno en los experimentos realizados.

  3. Sliding Mode Predictive Control of Main Steam Pressure in Coal-fired Power Plant Boiler

    Institute of Scientific and Technical Information of China (English)

    史元浩; 王景成; 章云锋

    2012-01-01

    Since the combustion system of coal-fired boiler in thermal power plant is characterized as time varying, strongly coupled, and nonlinear, it is hard to achieve a satisfactory performance by the conventional proportional integral derivative (PID) control scheme. For the characteristics of the main steam pressure in coal-fired power plant boiler, the sliding mode control system with Smith predictive structure is proposed to look for performance and robustness improvement. First, internal model control (IMC) and Smith predictor (SP) is used to deal with the time delay, and sliding mode controller (SMCr) is designed to overcome the model mismatch. Simulation results show the effectiveness of the proposed controller compared with conventional ones.

  4. Recycling a hydrogen rich residual stream to the power and steam plant

    Energy Technology Data Exchange (ETDEWEB)

    Martinez, P. [Instituto de Energia y Desarrollo Sustentable, CNEA, CONICET, Av. del Libertador 8250 Buenos Aires, Ciudad Autonoma de Buenos Aires (Argentina); Eliceche, A.M. [Chemical Engineering Department, Universidad Nacional del Sur, PLAPIQUI-CONICET, Camino La Carrindanga Km 7 (8000) Bahia Blanca (Argentina)

    2010-06-15

    The benefits of using a residual hydrogen rich stream as a clean combustion fuel in order to reduce Carbon dioxide emissions and cost is quantified. A residual stream containing 86% of hydrogen, coming from the top of the demethanizer column of the cryogenic separation sector of an ethylene plant, is recycled to be mixed with natural gas and burned in the boilers of the utility plant to generate high pressure steam and power. The main advantage is due to the fact that the hydrogen rich residual gas has a higher heating value and less CO{sub 2} combustion emissions than the natural gas. The residual gas flowrate to be recycled is selected optimally together with other continuous and binary operating variables. A Mixed Integer Non Linear Programming problem is formulated in GAMS to select the operating conditions to minimize life cycle CO{sub 2} emissions. (author)

  5. Steam generator tube support plate degradation in French plants: maintenance strategy

    Energy Technology Data Exchange (ETDEWEB)

    Gauchet, J.-P. [EDF, NPP Operations/Maintenance Dept. (France); Gillet, N. [FRAMATOME, Steam Generator Dept. (France); Stindel, M. [EDF, Central Labs. (France)

    1998-07-01

    This paper reports on the degradations of Steam Generator (SG) Tube Support Plates (TSPs) observed in French plants and the maintenance strategy adopted to continue operating the plant without any decrease of the required safety level. Only drilled carbon steel TSPs of early SGs are affected. Except the particular damage of the TSP8 of FESSENHEIM 2 caused by chemical cleaning procedures implemented in 1992, two main problems were observed almost exclusively on the upper TSP: Ligaments ruptured near the aseismic block located at 215 degrees. This degradation is perfectly detectable by bobbin coil inspection. It occurs very early in the life of the SG as can be seen from the records of previous inspections and no evolution of the signals was observed. This damage can be detected for 51M model SGs on several sites; Wastage of the ligaments resulting in enlargement of flow holes with in some cases complete consumption of a ligament. This damage was only observed for SGs of at GRAVELINES. This damage evolved cycle after cycle. Detailed studies were performed to analyze tubing behavior when a tube is not supported by the upper TSP because of missing ligaments. These studies evaluated the risk of vibratory instability, the behavior of both the TSP and the tubing in case of a seismic event or a LOCA and finally the behavior of the TSP in case of a Steam Line Break. Concerning vibratory instability it was possible to define zones where stability could not be demonstrated. Dampine, cables and sentinel plugs were then used when necessary to eliminate the risk of Steam Generator Tube Rupture (SGTR). For accidental conditions, it could be shown that no unacceptable damage occurs and that the core cooling function of the SG is always maintained if some tubes are plugged. From this analysis, It was possible to define the inspection programs for the different plants taking into account the specific situation of each plant regarding the damages detected. These programs include

  6. Global Freshwater Thermal Pollution from Steam-Electric Power Plants with Once-Through Cooling Systems

    Science.gov (United States)

    Raptis, C. E.; van Vliet, M. T. H.; Pfister, S.

    2015-12-01

    Thermoelectric power generation requires large amounts of cooling water. In facilities employing once-through cooling systems the heat removed in the power cycle is rejected directly into a water body. Several studies have focused on the impacts of power-related thermal emissions in Europe and the U.S., in terms of river temperature increase and the capacity for power production, especially in the light of legislative measures designed to protect freshwater bodies from excessive temperature. In this work we present a comprehensive, global analysis of current freshwater thermal pollution by thermoelectric facilities. The Platts World Electric Power Plant (WEPP) database was the principal data source. Data gaps in the principal parameters of the steam-electric power cycle were filled in by regression relationships developed in this work. Some 2400 steam-electric units using once-through freshwater cooling systems, amounting to 19% of the global installed capacity of thermoelectric units, were identified and georeferenced, and a global view of thermal emission rates was achieved by systematically solving the Rankine cycle on a power generating unit level. The rejected heat rates are linearly proportional to the steam flow rate, which in turn is directly proportional to the power produced. By applying the appropriate capacity factors, the rejected heat rate can be estimated for each unit or agglomeration of units at the desired temporal resolution. We coupled mean annual emission rates with the global gridded hydrological-river temperature model VIC-RBM to obtain a first view of river temperature increases resulting from power generation. The results show that in many cases, even on a mean annual emission rate basis and a relatively large spatial resolution of 0.5 x 0.5 degrees, the local limits for temperature increase are often exceeded, especially in the U.S. and Europe.

  7. Analysis of Heat Balance on Innovative-Simplified Nuclear Power Plant Using Multi-Stage Steam Injectors

    Science.gov (United States)

    Goto, Shoji; Ohmori, Shuichi; Mori, Michitsugu

    The total space and weight of the feedwater heaters in a nuclear power plant (NPP) can be reduced by replacing low-pressure feedwater heaters with high-efficiency steam injectors (SIs). The SI works as a direct heat exchanger between feedwater from condensers and steam extracted from turbines. It can attain pressures higher than the supplied steam pressure. The maintenance cost is lower than that of the current feedwater heater because of its simplified system without movable parts. In this paper, we explain the observed mechanisms of the SI experimentally and the analysis of the computational fluid dynamics (CFD). We then describe mainly the analysis of the heat balance and plant efficiency of the innovative-simplified NPP, which adapted to the boiling water reactor (BWR) with the high-efficiency SI. The plant efficiencies of this innovative-simplified BWR with SI are compared with those of a 1100MWe-class BWR. The SI model is adopted in the heat balance simulator as a simplified model. The results show that the plant efficiencies of the innovate-simplified BWR with SI are almost equal to those of the original BWR. They show that the plant efficiency would be slightly higher if the low-pressure steam, which is extracted from the low-pressure turbine, is used because the first-stage of the SI uses very low pressure.

  8. Multi-region fuzzy logic controller with local PID controllers for U-tube steam generator in nuclear power plant

    Directory of Open Access Journals (Sweden)

    Puchalski Bartosz

    2015-12-01

    Full Text Available In the paper, analysis of multi-region fuzzy logic controller with local PID controllers for steam generator of pressurized water reactor (PWR working in wide range of thermal power changes is presented. The U-tube steam generator has a nonlinear dynamics depending on thermal power transferred from coolant of the primary loop of the PWR plant. Control of water level in the steam generator conducted by a traditional PID controller which is designed for nominal power level of the nuclear reactor operates insufficiently well in wide range of operational conditions, especially at the low thermal power level. Thus the steam generator is often controlled manually by operators. Incorrect water level in the steam generator may lead to accidental shutdown of the nuclear reactor and consequently financial losses. In the paper a comparison of proposed multi region fuzzy logic controller and traditional PID controllers designed only for nominal condition is presented. The gains of the local PID controllers have been derived by solving appropriate optimization tasks with the cost function in a form of integrated squared error (ISE criterion. In both cases, a model of steam generator which is readily available in literature was used for control algorithms synthesis purposes. The proposed multi-region fuzzy logic controller and traditional PID controller were subjected to broad-based simulation tests in rapid prototyping software - Matlab/Simulink. These tests proved the advantage of multi-region fuzzy logic controller with local PID controllers over its traditional counterpart.

  9. Development of Technologies on Innovative-Simplified Nuclear Power Plant using High-Efficiency Steam Injectors

    Science.gov (United States)

    Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu; Iwaki, Chikako; Asanuma, Yutaka; Goto, Shoji

    A Steam Injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "High-Efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and Emergency Core Cooling System of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a Severe Accident-Free Concept). This paper describes the results of the endurance and performance tests of low-pressure SIs for feed-water heaters with Jet-deaerator and core injection system.

  10. Aging influence on exergy destruction in an operating 320MW steam power plant

    Science.gov (United States)

    Salari, Sina; Abroshan, Hamid

    2012-06-01

    Exergy analysis in power plants is a strong tool to evaluate cycle performance qualitatively. Most of previous studies applied second law approach to find optimum values for main cycle parameters. Although, these researches are useful to improve the design features of future power plants, they do not imply any recommendation to improve an aged unit. In This study an exergy analysis of an operating unit was performed to clear main sources of exergy destruction. Second law efficiency and exergy losses of all main components in the steam power plant, which is located in the south of Iran, were calculated based on present data. To find out aging influence on the plant performance, outcomes were compared with design results. This comparison cleared components which affected by aging, and the amount of miss performance were specified too. Boiler and high pressure turbine (HP) were the most influenced components due to aging effects. Besides, the calculations were done at three loads in order to evaluate performance of components in off design conditions.

  11. PERFORMANCE EVALUATION OF BOILERS (80 AND 40 TPH AND 21MW STEAM TURBINE OF COGEN PLANT

    Directory of Open Access Journals (Sweden)

    D.P.TAWARE

    2014-06-01

    Full Text Available The proposed study is conducted at The Malegaon Sugar Mills, Baramati, and District Pune. Data is collected for a high pressure 80 TPH & 40TPH bagasse fired boiler. The boilers are natural circulation and bi-drum water tube type. The both boilers are equipped with super heater, air heater and economizer in order to utilize maximum available heat of flue gases. Boiler efficiency is calculated by indirect method. Also plant has 21 MW cogeneration capacity, with two turbines are installed with capacity 14MW (Back Pressure Type & 7MW (Extraction Cum Condensing Type. From the heat input given to turbines per unit of electricity generated, the turbine heat rate is calculated. Different instruments and devices are used to record the different parameters of both boilers & turbines. Steam produced per ton of bagasse is being found out for both boilers.

  12. Mechanical and oxidation testing of advanced materials for steam power plants

    Energy Technology Data Exchange (ETDEWEB)

    Bontempi, P.; Guardamagna, C.; Ricci, N.; Torri, L. [CESI, Segrate (Milano) (Italy)

    2002-07-01

    In the frame of the COST522 programme, Steam Power Plant Working Group, CESI is carrying out an experimental programme in order to evaluate boiler and turbine innovative materials suitable for applications up to 650 C. In this paper results from Low Cycle Fatigue, creep and oxidation-corrosion testing are presented. LCF tests at T=600 C have been performed on a new cast steel (CB6), evaluating also the effect of hold time period. The preliminary creep results at T=625 C on four new 11%Cr ferritic steels for piping are presented: the experimentation is still in progress. The steamside corrosion - oxidation test results at T=600 C and T=650 till now obtained on both boiler and turbine innovative materials are shown. (orig.)

  13. Modeling Creep-Fatigue-Environment Interactions in Steam Turbine Rotor Materials for Advanced Ultra-supercritical Coal Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Shen, Chen [General Electric Global Research, Niskayuna, NY (United States)

    2014-04-01

    The goal of this project is to model creep-fatigue-environment interactions in steam turbine rotor materials for advanced ultra-supercritical (A-USC) coal power Alloy 282 plants, to develop and demonstrate computational algorithms for alloy property predictions, and to determine and model key mechanisms that contribute to the damages caused by creep-fatigue-environment interactions.

  14. Multi-Sector General Permit Annual Industrial Storm Water Training, TA-3-22 Power and Steam Plant (Sector 0)

    Energy Technology Data Exchange (ETDEWEB)

    Shendo, Marwin Patrick [Los Alamos National Lab. (LANL), Los Alamos, NM (United States)

    2015-01-12

    This report offers training for employees who work at TA-3-22, the Power and Steam Plant that move product, metal, and other pollutants like oil, fuel, equipment, pumps, etc. outside or that work outside with industrial materials exposed to storm water.

  15. Analysis of ethylene plant steam treatment interruption%乙烯装置蒸汽中断处理分析

    Institute of Scientific and Technical Information of China (English)

    刘伟东

    2015-01-01

    本文基于SW公司前脱丙烷前加氢工艺,介绍蒸汽中断条件下,为确保装置损失最小、装置平稳运行及安全环保前提下,乙烯装置如何进行操作处理。%This paper introduces the operation of ethylene plant under the condition of steam interruption,which is based on the technology of hydrogenation of SW before removing propane and the condition of steam interruption.

  16. Intelligent coordinated control of power-plant main steam pressure and power output

    Institute of Scientific and Technical Information of China (English)

    刘红波; 李少远; 柴天佑

    2004-01-01

    An intelligent coordinated control strategy has been proposed and successfully applied to a 300MW boiler-turbine unit i.e. Unit 1 of Yuanbaoshan power plant in China. Load following operation of coal-fired boiler-turbine unit in the power plant leads to changes in operating points which result in nonlinear variations of the plant variables and parameters. For the variation of operating condition and slowly varying dynamics, an intelligent control scheme has been developed by combining fuzzy self-tuning with adaptive control and auto-tuning techniques. As there exist strong couplings between control loops of main steam pressure and power output in the unit, a new design for static decoupler aimed at decoupling for setpoints and unmeasured pulverized coal disturbance of the system at the same time is presented. Satisfactory industrial application results show that such a control system has enhanced adaptability and robustness to the complex process, and better control performance and high economic benefit have been obtained.

  17. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2003-01-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power & Gasification (now ChevronTexaco), SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the U. S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the technoeconomic viability of building an Early Entrance Co-Production Plant (EECP) in the United States to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases. Phase I is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III updates the original EECP design based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report covers the period performance from July 1, 2002 through September 30, 2002.

  18. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    OpenAIRE

    Masoud Rokni

    2016-01-01

    Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC). High temperature fuel cells (such as solid oxide fuel cell (SOFC)) could also be used as a ...

  19. A Study on the Air Vent Valve of the Hydraulic Servo Actuator for Steam Control of Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Lee, Yong Bum; Lee, Jong Jik [Korea Institute of Machinery and Materials, Daejeon (Korea, Republic of)

    2016-06-15

    To produce adequate electricity in nuclear and thermal power plants, an optimal amount of steam should be supplied to a generator connected to high- and low-pressure steam turbines. A turbine output control device, which is a special steam valve employed to supply or interrupt the steam to the turbine, is operated using a hydraulic servo actuator. In power plants, the performance of servo actuators is degraded by the air generated from the hydraulic system, or causes frequent failures owing to an increase in the wear of the seal. This is due to the seal being burnt as generated heat using the produced compressed air. Some power plants have exhausted air using a fixed orifice, and thus they encounter power loss due to mass flow exhaust. Failures are generated in hydraulic pumps, electric motors, and valves, which are frequently operated. In this study, we perform modeling and analysis of the load-sensing air-exhaust valves, which can be passed through very fine flow under normal use conditions, and exhaust mass flow air at the beginning stage as with existing fixed orifices. Then, we propose a method to prevent failures due to the compressed air, and to ensure the control accuracy of hydraulic servo actuators.

  20. Evaluation of a sulfur oxide chemical heat storage process for a steam solar electric plant

    Energy Technology Data Exchange (ETDEWEB)

    Dayan, J.; Lynn, S.; Foss, A.

    1979-07-01

    The purpose of this study was to develop and evaluate technically feasible process configurations for the use of the sulfur oxide system, 2 SO/sub 3/ reversible 2 SO/sub 2/ + O/sub 2/, in energy storage. The storage system is coupled with a conventional steam-cycle power plant. Heat for both the power plant and the storage system is supplied during sunlit hours by a field of heliostats focussed on a central solar receiver. When sunlight is not available, the storage system supplies the heat to operate the power plant. A technically feasible, relatively efficient configuration is proposed for incorporating this type of energy storage system into a solar power plant. Complete material and energy balances are presented for a base case that represents a middle range of expected operating conditions. Equipment sizes and costs were estimated for the base case to obtain an approximate value for the cost of the electricity that would be produced from such an installation. In addition, the sensitivity of the efficiency of the system to variations in design and operating conditions was determined for the most important parameters and design details. In the base case the solar tower receives heat at a net rate of 230 MW(t) for a period of eight hours. Daytime electricity is about 30 MW(e). Nighttime generation is at a rate of about 15 MW(e) for a period of sixteen hours. The overall efficiency of converting heat into electricity is about 26%. The total capital cost for the base case is estimated at about $68 million, of which about 67% is for the tower and heliostats, 11% is for the daytime power plant, and 22% is for the storage system. The average cost of the electricity produced for the base case is estimated to be about 11 cents/kW(e)-hr.

  1. Containment fan cooler heat transfer calculation during main steam line break for Maanshan PWR plant

    Energy Technology Data Exchange (ETDEWEB)

    Yuann, Yng-Ruey, E-mail: ryyuann@iner.gov.tw; Kao, Lain-Su, E-mail: lskao@iner.gov.tw

    2013-10-15

    Highlights: • Evaluate component cooling water (CCW) thermal response during MSLB for Maanshan. • Using GOTHIC to calculate CCW temperature and determine time required to boil CCW. • Both convective and condensation heat transfer from the air side are considered. • Boiling will not occur since T{sub B} is sufficiently longer than CCW pump restart time. -- Abstract: A thermal analysis has been performed for the Containment Fan Cooler Unit (FCU) during Main Steam Line Break (MSLB) accident, concurrent with loss of offsite power, for Maanshan PWR plant. The analysis is performed in order to address the waterhammer and two-phase flow issues discussed in USNRC's Generic Letter 96-06 (GL 96-06). Maanshan plant is a twin-unit Westinghouse 3-loop PWR currently operated at rated core thermal power of 2822 MWt for each unit. The design basis for containment temperature is Main Steam Line Break (MSLB) accident at power of 2830.5 MWt, which results in peak vapor temperature of 387.6 °F. The design is such that when MSLB occurs concurrent with loss of offsite power (MSLB/LOOP), both the coolant pump on the secondary side and the fan on the air side of the FCU loose power and coast down. The pump has little inertia and coasts down in 2–3 s, while the FCU fan coasts down over much longer period. Before the pump is restored through emergency diesel generator, there is potential for boiling the coolant in the cooling coils by the high-temperature air/steam mixture entering the FCU. The time to boiling depends on the operating pressure of the coolant before the pump is restored. The prediction of the time to boiling is important because it determines whether there is potential for waterhammer or two-phase flow to occur before the pump is restored. If boiling occurs then there exists steam region in the pipe, which may cause the so called condensation induced waterhammer or column closure waterhammer. In either case, a great amount of effort has to be spent to

  2. Nuclear power plant steam pipes repairing with Tirant 3 Robot system

    Energy Technology Data Exchange (ETDEWEB)

    Soto, M.; Curiel, M. [Logistica y Acondicionamientos Industriales SAU, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Lazaro, F. [Revestimientos Anticorrosivos Industriales, S. L. U., Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain); Arnaldos, A., E-mail: m.soto@lainsa.co [TITANIA Servicios Tecnologicos SL, Sorolla Center, local 10, Av. de las Cortes Valencianas No. 58, 46015 Valencia (Spain)

    2010-10-15

    The metallization arc spray process is based on the projection of molten metal, supplied by means of different stainless alloys wire, over a surface of carbon steel usually, with the object of serving as protection against erosion-corrosion, increasing resistance to abrasion and detrition. A typical application functions covering the steam pipes inner surface in coal-fired power station and nuclear power plants. The results of this process are spectacular in terms of protection against corrosion and abrasion, but its application has conditioning factors, such as: Severe application conditions for workers. Due to the worker's postural position (usually kneeling) in 32 diameter pipes and working with fireproof clothing and masks with outdoor air supplying, due to fumes, sparks and molten metal particles, radiological contamination, confined space, poor lighting, ... Coating uniformity. As metallization is a manual process, the carried out measurements show small variations in the thickness of the coating, always within the tolerance limits established by the applicable regulations and quality assurance. An increase in the uniformity of the projected coating, increase the resistance and give a better surface protection. For all these reasons, Lainsa has developed the Tirant 3 robot, a worldwide innovative system, for metallization of steam pipes inner surface. Tirant 3 robot is tele operated from outside of the pipe, so that human intervention is reduced to the operations of robot positioning and change of metallization wire. As it is an independent system of the human factor, metallization process performance is significantly increased by reducing rest periods due only to the robot maintenance. Likewise, Tirant 3 system permits to increase resulting coating uniformity and thus its resistance, keeping selected parameters constant (forward speed, rotation speed and inner surface distance) depending on required type and thickness of wire. (Author)

  3. Status of the steam generator tube circumferential ODSCC degradation experienced at the Doel 4 plant

    Energy Technology Data Exchange (ETDEWEB)

    Roussel, G. [AIB-Vincotte Nuclear, Brussels (Belgium)

    1997-02-01

    Since the 1991 outage, the Doel Unit 4 nuclear power plant is known to be affected by circumferential outside diameter intergranular stress corrosion cracking at the hot leg tube expansion transition. Extensive non destructive examination inspections have shown the number of tubes affected by this problem as well as the size of the cracks to have been increasing for the three cycles up to 1993. As a result of the high percentage of tubes found non acceptable for continued service after the 1993 in-service inspection, about 1,700 mechanical sleeves were installed in the steam generators. During the 1994 outage, all the tubes sleeved during the 1993 outage were considered as potentially cracked to some extent at the upper hydraulic transition and were therefore not acceptable for continued service. They were subsequently repaired by laser welding. Furthermore all the tubes not sleeved during the 1993 outage were considered as not acceptable for continued service and were repaired by installing laser welded sleeves. During the 1995 outage, some unexpected degradation phenomena were evidenced in the sleeved tubes. This paper summarizes the status of the circumferential ODSCC experienced in the SG tubes of the Doel 4 plant as well as the other connected degradation phenomena.

  4. Steam oxidation of TP 347H FG. Laboratory exposures versus service conditions at the power plant

    Energy Technology Data Exchange (ETDEWEB)

    Hansson, Anette N. [DONG Energy A/S, Copenhagen (Denmark); Montgomery, Melanie [DONG Energy A/S, Copenhagen (Denmark); Technical Univ. of Denmark, Lyngby (Denmark). Dept. of Mechanical Engineering; Vattenfall Heat Nordic, Copenhagen (Denmark)

    2010-07-01

    TP347H FG is often used as final superheater tubing at Danish Power Plants. The oxidation behaviour of TP347H FG in steam was investigated both in laboratory conditions and field conditions. Short time exposures (336 hours) were performed in the laboratory at 500, 600 and 700 C in gasses with 8 or 46% H{sub 2}O and varying oxygen partial pressures. The shortest exposure time at the power plant was 7720 h, the temperature varied between 500 and 650 C. Surprisingly, thicker oxide layers formed within the laboratory facility at 600 and 700 C than during the long time exposures at the power plant. This could not be explained by spallation. Double-layered oxides developed during oxidation. The outer layer consist of Fe-oxides and the inner oxide contained Fe and the remaining alloy elements. Investigations with scanning electron microscopy (SEM) revealed that the morphology of the inner oxide was different for the two types of exposures. However, investigation using transmission electron microscopy (TEM) showed that the inner oxide in both cases consisted of particles of Fe-Mn-Cr spinel embedded in a metallic Fe-Ni matrix in the bulk of the (former) alloy grains and Cr-rich oxide layer along the (former) alloy grain boundaries. The main difference between the layers formed at the two locations is that the Cr-rich oxide layer is thicker for the samples exposed at the power plant than that for the samples exposed at the laboratory conditions. Furthermore, the depth of Cr depletion in the alloy adjacent the oxide layer is greater for the samples exposed at the power plant compared to those exposed in the laboratory. The microstructure investigation suggests that the slower oxidation rate of TP347H FG at the power plant as compared to the laboratory is due to a larger reservoir of Cr for the samples exposed at the power plant probably combined with a higher mobility of Cr within the alloy. (orig.)

  5. An innovative approach for Steam Generator Pressure Control of a nuclear power plant

    Energy Technology Data Exchange (ETDEWEB)

    Gaikwad, Avinash J., E-mail: avinashg@barc.gov.in [Reactor Safety Division, BARC, Trombay, Mumbai 400094 (India); Vijayan, P.K. [Reactor Engineering Divisions, BARC, Trombay, Mumbai 400094 (India); Bhartiya, Sharad [Chemical Engineering Departments, IIT, Powai, Mumbai (India); Kumar, Rajesh; Lele, H.G.; Vaze, K.K. [Reactor Safety Division, BARC, Trombay, Mumbai 400094 (India)

    2011-12-15

    Highlights: Black-Right-Pointing-Pointer Most of the transients/accidents have their origin in the mismatch among the heat generated in the reactor core and the heat removal in the SGs. Black-Right-Pointing-Pointer The main objective of balancing the heat generation, transfer and removal gets lost due to simplification of SGPC leading to reduced availability. Black-Right-Pointing-Pointer A new Advanced Process Control (APC) is proposed to ride over the existing SGPC to achieve the goal of prompt removal of the heat transfer mismatch. Black-Right-Pointing-Pointer The APC logic will lead to overall performance improvements and plant availability for all other transients also. - Abstract: The main function of the Steam Generator Pressure Control (SGPC) Program is to match the power (heat) generation in the reactor core with the heat removal in the steam generators (SGs). For most of the designs these programs have been over simplified to cater to the limitation of the instrumentation and control, hardware and software. The main objective of balancing the heat generation, transfer and removal gets lost in the process, which leads to reduction in the availability of the nuclear power plant. This is reflected in under utilization of the process and control system provisions to avoid reactor trips on low/high pressure. Most of the transients/accidents have their origin in the mismatch among the heat generated in the reactor core and the heat removal in the SGs. A new Advanced Process Control (APC) based supervisory controller is proposed to ride over the existing SGPC to achieve the goal. This APC makes use of the estimated/measured heat generation-removal error to alter the SGPC set point to tide over the transients after detection. The transients are detected based on the magnitude of this error to activate the APC. After tiding over the transient successfully the control switches back to the existing SGPC. For evaluation of this error additional instrumentation is

  6. A Differential-Algebraic Model for the Once-Through Steam Generator of MHTGR-Based Multimodular Nuclear Plants

    Directory of Open Access Journals (Sweden)

    Zhe Dong

    2015-01-01

    Full Text Available Small modular reactors (SMRs are those fission reactors whose electrical output power is no more than 300 MWe. SMRs usually have the inherent safety feature that can be applicable to power plants of any desired power rating by applying the multimodular operation scheme. Due to its strong inherent safety feature, the modular high temperature gas-cooled reactor (MHTGR, which uses helium as coolant and graphite as moderator and structural material, is a typical SMR for building the next generation of nuclear plants (NGNPs. The once-through steam generator (OTSG is the basis of realizing the multimodular scheme, and modeling of the OTSG is meaningful to study the dynamic behavior of the multimodular plants and to design the operation and control strategy. In this paper, based upon the conservation laws of mass, energy, and momentum, a new differential-algebraic model for the OTSGs of the MHTGR-based multimodular nuclear plants is given. This newly-built model can describe the dynamic behavior of the OTSG in both the cases of providing superheated steam and generating saturated steam. Numerical simulation results show the feasibility and satisfactory performance of this model. Moreover, this model has been applied to develop the real-time simulation software for the operation and regulation features of the world first underconstructed MHTGR-based commercial nuclear plant—HTR-PM.

  7. Steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Beckmann, G.; Gilli, P.V.; Fritz, K.; Lippitsch, J.

    1975-12-02

    A steam generator is disclosed which is particularly adapted to be used in nuclear power plants. A casing is provided with an inlet and outlet to receive and discharge a primary heating fluid from which heat is to be extracted. A pair of tube plates extend across the interior of the casing at the region of the inlet and outlet thereof, and a plurality of tubes extend along the interior of the casing and are connected in parallel between the tube plates with all of the tubes having open ends communicating with the inlet and outlet of the casing so that the primary heating fluid will flow through the interior of the tubes while a fluid in the casing at the exterior of the tubes will extract heat from the primary fluid. The casing has between the tubes at the region of the inlet a superheating chamber and at the region of the outlet a preheating chamber and between the latter chambers an evaporating chamber, the casing receiving water through an inlet at the preheating chamber and discharging superheated steam through an outlet at the superheating chamber. A separator communicates with the evaporating chamber to receive a mixture of steam and water therefrom for separating the steam from the water and for delivering the separated steam to the superheating chamber.

  8. Energy and exergy analysis of the Kalina cycle for use in concentrated solar power plants with direct steam generation

    DEFF Research Database (Denmark)

    Knudsen, Thomas; Clausen, Lasse Røngaard; Haglind, Fredrik

    2014-01-01

    In concentrated solar power plants using direct steam generation, the usage of a thermal storage unit based only on sensible heat may lead to large exergetic losses during charging and discharging, due to a poor matching of the temperature profiles. By the use of the Kalina cycle, in which...... evaporation and condensation takes place over a temperature range, the efficiency of the heat exchange processes can be improved, possibly resulting also in improved overall performance of the system. This paper is aimed at evaluating the prospect of using the Kalina cycle for concentrated solar power plants...... with direct steam generation. The following two scenarios were addressed using energy and exergy analysis: generating power using heat from only the receiver and using only stored heat. For each of these scenarios comparisons were made for mixture concentrations ranging from 0.1 mole fraction of ammonia to 0...

  9. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    Directory of Open Access Journals (Sweden)

    Masoud Rokni

    2016-05-01

    Full Text Available Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC. High temperature fuel cells (such as solid oxide fuel cell (SOFC could also be used as a topping cycle, achieving even higher global plant efficiency and even lower specific CO2 emissions. Decreasing the operating temperature in a SOFC allows the use of less complex materials and construction methods, consequently reducing plant and the electricity costs. A lower working temperature makes it also suitable for topping an existing steam cycle, instead of gas turbines. This is also the target of this study, repowering of an existing power plant with SOFC as well as gas turbines. Different repowering strategies are studied here, repowering with one gas turbine with and without supplementary firing, repowering with two gas turbines with and without supplementary firing and finally repowering using SOFC. Plant performances and CO2 emissions are compared for the suggested repowered plants.

  10. Status on the Component Models Developed in the Modelica Framework: High-Temperature Steam Electrolysis Plant & Gas Turbine Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    Suk Kim, Jong [Idaho National Lab. (INL), Idaho Falls, ID (United States); McKellar, Michael [Idaho National Lab. (INL), Idaho Falls, ID (United States); Bragg-Sitton, Shannon M. [Idaho National Lab. (INL), Idaho Falls, ID (United States); Boardman, Richard D. [Idaho National Lab. (INL), Idaho Falls, ID (United States)

    2016-10-01

    This report has been prepared as part of an effort to design and build a modeling and simulation (M&S) framework to assess the economic viability of a nuclear-renewable hybrid energy system (N-R HES). In order to facilitate dynamic M&S of such an integrated system, research groups in multiple national laboratories have been developing various subsystems as dynamic physics-based components using the Modelica programming language. In fiscal year (FY) 2015, Idaho National Laboratory (INL) performed a dynamic analysis of two region-specific N-R HES configurations, including the gas-to-liquid (natural gas to Fischer-Tropsch synthetic fuel) and brackish water reverse osmosis desalination plants as industrial processes. In FY 2016, INL has developed two additional subsystems in the Modelica framework: a high-temperature steam electrolysis (HTSE) plant and a gas turbine power plant (GTPP). HTSE has been proposed as a high priority industrial process to be integrated with a light water reactor (LWR) in an N-R HES. This integrated energy system would be capable of dynamically apportioning thermal and electrical energy (1) to provide responsive generation to the power grid and (2) to produce alternative industrial products (i.e., hydrogen and oxygen) without generating any greenhouse gases. A dynamic performance analysis of the LWR/HTSE integration case was carried out to evaluate the technical feasibility (load-following capability) and safety of such a system operating under highly variable conditions requiring flexible output. To support the dynamic analysis, the detailed dynamic model and control design of the HTSE process, which employs solid oxide electrolysis cells, have been developed to predict the process behavior over a large range of operating conditions. As first-generation N-R HES technology will be based on LWRs, which provide thermal energy at a relatively low temperature, complementary temperature-boosting technology was suggested for integration with the

  11. The VGB guidelines for organic matter and dissolved carbon dioxide in the steam-water circuit of power plant - an interim report by the working group

    Energy Technology Data Exchange (ETDEWEB)

    Aspden, J.D. [Eskom, Chemistry and Auxiliary Plant Engineering, Johannesburg (South Africa); Bellows, J.C. [Westinghouse Power Generation, Orlando, FL (United States); Hein, M. [Preussen Elektra, Kraftwerk Staudinger, Grosskrotzenburg (Germany); Huber, S. [DOC-Labor, IHK Technologiefabrik, Karlsruhe (Germany); Maughan, E.V. [Tablar Messtechnik Ges. mbH, Duisburg (Germany); Pflug, H.D.; Rziha, M. [Siemens AG, KWU, Power Generation (KWU), Erlangen (Germany); Seipp, H.-G. [ABB Technikdienste and Logistik GmbH, TDL/C, Mannheim (Germany); Svoboda, R. [ABB Power Generation Ltd., Power Plant Chemistry, Baden (Switzerland); Woost, O. [Solvay Alkali Bernburg GmbH, Bernburg (Germany); Zeijseink, A.G.L. [KEMA Power Generation, ET Arnhem (Netherlands)

    1999-07-01

    Although no overwhelming evidence exists, organic acids and carbon dioxide have nevertheless been implicated as contributors to corrosion problems within the steam-water circuit. A dedicated group of international scientists and power plant chemists has been commissioned under the auspices of the VGB to examine and document the impact of organic matter and dissolved carbon dioxide on materials of construction in the steam-water circuit of power plant. (orig.)

  12. 2008 USGS South New Jersey County Project Lidar: Cumberland County

    Data.gov (United States)

    National Oceanic and Atmospheric Administration, Department of Commerce — The South New Jersey County Lidar Project is to provide LiDAR data for the New Jersey Department of Environmental Protection (NJ-DEP) for Cape May, Cumberland, and...

  13. Isobar gas and steam. Compressed air storage plant with heat storage; Isobares GuD. Druckluftspeicherkraftwrk mit Waermespeicher

    Energy Technology Data Exchange (ETDEWEB)

    Schlitzberger, Christian; Leithner, Reinhard; Nielsen, Lasse [Technische Univ. Braunschweig (Germany). Inst. fuer Waerme- und Brennstofftechnik

    2008-07-01

    Due to the worldwide increasing energy consumption the unfavourable aspects of the today's power supply structure are strengthened continuously. There are two compressed air energy storage power stations existing. However, these power stations exhibit worse efficiencies of storage in comparison to existing pumped-storage power plants. In order to avoid this disadvantage, a concept of a isobaric gas and steam compressed air storage plant was developed at the institute for heat and fuel technology at the technical university of Braunschweig. This concept is presented in the contribution under consideration.

  14. Impact of drought on U.S. steam electric power plant cooling water intakes and related water resource management issues.

    Energy Technology Data Exchange (ETDEWEB)

    Kimmell, T. A.; Veil, J. A.; Environmental Science Division

    2009-04-03

    This report was funded by the U.S. Department of Energy's (DOE's) National Energy Technology Laboratory (NETL) Existing Plants Research Program, which has an energy-water research effort that focuses on water use at power plants. This study complements their overall research effort by evaluating water availability at power plants under drought conditions. While there are a number of competing demands on water uses, particularly during drought conditions, this report focuses solely on impacts to the U.S. steam electric power plant fleet. Included are both fossil-fuel and nuclear power plants. One plant examined also uses biomass as a fuel. The purpose of this project is to estimate the impact on generation capacity of a drop in water level at U.S. steam electric power plants due to climatic or other conditions. While, as indicated above, the temperature of the water can impact decisions to halt or curtail power plant operations, this report specifically examines impacts as a result of a drop in water levels below power plant submerged cooling water intakes. Impacts due to the combined effects of excessive temperatures of the returned cooling water and elevated temperatures of receiving waters (due to high ambient temperatures associated with drought) may be examined in a subsequent study. For this study, the sources of cooling water used by the U.S. steam electric power plant fleet were examined. This effort entailed development of a database of power plants and cooling water intake locations and depths for those plants that use surface water as a source of cooling water. Development of the database and its general characteristics are described in Chapter 2 of this report. Examination of the database gives an indication of how low water levels can drop before cooling water intakes cease to function. Water level drops are evaluated against a number of different power plant characteristics, such as the nature of the water source (river vs. lake or reservoir

  15. EARLY ENTRANCE CO-PRODUCTION PLANT - DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    John W. Rich

    2003-12-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power & Gasification (now ChevronTexaco), SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the U. S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the United States to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases. Phase I is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III updates the original EECP design based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report covers the period performance from July 1, 2003 through September 30, 2003. The DOE/WMPI Cooperative Agreement was modified on May 2003 to expand the project team to include Shell Global Solutions, U.S. and Uhde GmbH as the engineering contractor. The addition of Shell and Uhde strengthen both the technical capability and financing ability of the project. Uhde, as the prime EPC contractor, has the responsibility to develop a LSTK (lump sum turnkey) engineering design package for the EECP leading to the eventual detailed engineering, construction and operation of the proposed concept. Major technical activities during the reporting

  16. Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 5: Combined gas-steam turbine cycles. [energy conversion efficiency in electric power plants

    Science.gov (United States)

    Amos, D. J.; Foster-Pegg, R. W.; Lee, R. M.

    1976-01-01

    The energy conversion efficiency of gas-steam turbine cycles was investigated for selected combined cycle power plants. Results indicate that it is possible for combined cycle gas-steam turbine power plants to have efficiencies several point higher than conventional steam plants. Induction of low pressure steam into the steam turbine is shown to improve the plant efficiency. Post firing of the boiler of a high temperature combined cycle plant is found to increase net power but to worsen efficiency. A gas turbine pressure ratio of 12 to 1 was found to be close to optimum at all gas turbine inlet temperatures that were studied. The coal using combined cycle plant with an integrated low-Btu gasifier was calculated to have a plant efficiency of 43.6%, a capitalization of $497/kW, and a cost of electricity of 6.75 mills/MJ (24.3 mills/kwh). This combined cycle plant should be considered for base load power generation.

  17. Evaluation of Efficiency in Steam Generator of C3 Power Plant at Cap Des Biches in Dakar

    Directory of Open Access Journals (Sweden)

    A. Kane

    2012-07-01

    Full Text Available The aim of the present study is to determine the efficiency of the power plant boiler steam C3 Cape deer and to evaluate the impact of it. We chose to calculate the return by the empirical formula of Martin which is based on two important parameters which are the temperature at the exit of the chimney and the ambient temperature. The calculation of these efficiencies allowed us to make comparative studies with data from the manufacturer and we have detected anomalies. On this basis we made a number of recommendations for improvement of the groups in normal, the application will lead to an optimization of the real exploitation of groups and a performance improvement. We gave various reasons for poor performance of steam generators and recommendations that can be used both in production efficiency on compliance with operating instructions. Solutions have been proposed after diagnosis with particular emphasis on compliance with operating instructions and maintenance schedule.

  18. Performance Comparison on Repowering of a Steam Power Plant with Gas Turbines and Solid Oxide Fuel Cells

    DEFF Research Database (Denmark)

    Rokni, Masoud

    2016-01-01

    Repowering is a process for transforming an old power plant for greater capacity and/or higher efficiency. As a consequence, the repowered plant is characterized by higher power output and less specific CO2 emissions. Usually, repowering is performed by adding one or more gas turbines...... of this study, repowering of an existing power plant with SOFC as well as gas turbines. Different repowering strategies are studied here, repowering with one gas turbine with and without supplementary firing, repowering with two gas turbines with and without supplementary firing and finally repowering using...... into an existing steam cycle which was built decades ago. Thus, traditional repowering results in combined cycles (CC). High temperature fuel cells (such as solid oxide fuel cell (SOFC)) could also be used as a topping cycle, achieving even higher global plant efficiency and even lower specific CO2 emissions...

  19. Application of Spherical Steam Accumulator in the Saturated Steam Power Generation Technology of Steel Plants%球形蒸汽蓄能器在钢铁厂饱和蒸汽发电技术中的应用

    Institute of Scientific and Technical Information of China (English)

    杨学友; 祝百东; 周春丽

    2014-01-01

    介绍了某钢铁公司回收厂区富余饱和蒸汽进行发电的方案,着重介绍了球形蒸汽蓄能器的原理及特点,并与卧式筒形蓄热器进行对比。球形蒸汽蓄能器具有占地少、投资省、系统简化、蒸汽含水率低等优点,推荐在钢铁厂饱和蒸汽回收利用中广泛采用球形蒸汽蓄能器。%The plan for recovering surplus steam in a steel plant to generate power is introduced focusing on the principle and characteristics of spherical steam accumulator, which is compared with horizontal cylinder-type accumulator. Spherical steam accumulator has the advantages of less land occupation, smaller investment, simplified system and lower water con-tent in the steam, deserving to be widely promoted in applications of saturated steam recovery and utilization in steel plants.

  20. 76 FR 4147 - Putnam-Cumberland, TN-Improve Power Supply

    Science.gov (United States)

    2011-01-24

    ... Putnam-Cumberland, TN--Improve Power Supply AGENCY: Tennessee Valley Authority. ACTION: Notice of intent... supply improvements in the Putnam and Cumberland region of east-central Tennessee. The purpose of the... approximately 16,000 miles of transmission lines. TVA supplies bulk electric power to Cumberland and...

  1. Operating test report for project W-417, T-plant steam removal upgrade, waste transfer portion

    Energy Technology Data Exchange (ETDEWEB)

    Myers, N.K.

    1997-10-21

    This Operating Test Report (OTR) documents the performance results of the Operating Test Procedure HNF-SD-W417-OTP-001 that provides steps to test the waste transfer system installed in the 221-T Canyon under project W-417. Recent modifications have been performed on the T Plant Rail Car Waste Transfer System. This Operating Test Procedure (OTP) will document the satisfactory operation of the 221-T Rail Car Waste Transfer System modified by project W-417. Project W-417 installed a pump in Tank 5-7 to replace the steam jets used for transferring liquid waste. This testing is required to verify that operational requirements of the modified transfer system have been met. Figure 2 and 3 shows the new and existing system to be tested. The scope of this testing includes the submersible air driven pump operation in Tank 5-7, liquid waste transfer operation from Tank 5-7 to rail car (HO-IOH-3663 or HO-IOH-3664), associated line flushing, and the operation of the flow meter. This testing is designed to demonstrate the satisfactory operation-of the transfer line at normal operating conditions and proper functioning of instruments. Favorable results will support continued use of this system for liquid waste transfer. The Functional Design Criteria for this system requires a transfer flow rate of 40 gallons per minute (GPM). To establish these conditions the pump will be supplied up to 90 psi air pressure from the existing air system routed in the canyon. An air regulator valve will regulate the air pressure. Tank capacity and operating ranges are the following: Tank No. Capacity (gal) Operating Range (gal) 5-7 10,046 0 8040 (80%) Rail car (HO-IOH-3663 HO-IOH-3664) 097219,157 Existing Tank level instrumentation, rail car level detection, and pressure indicators will be utilized for acceptance/rejection Criteria. The flow meter will be verified for accuracy against the Tank 5-7 level indicator. The level indicator is accurate to within 2.2 %. This will be for information only

  2. Development and realization of the concept of an integrated system for the improvement of steam turbine plant reliability

    Science.gov (United States)

    Murmanskii, B. E.

    2015-12-01

    Main works performed when implementing the concept of an integrated approach to the improvement of the steam turbine plant (STP) reliability were stated. The technique of an integrated approach to the collection and processing of data on the STP equipment reliability was presented. This technique is based on the information on damages resulting in equipment failures, damages revealed during the routine equipment maintenance, and on data concerning equipment faults occurred when operating the STP. There is an implementation example for the technique of defining main elements specifying the reliability of a specific unit based on the statistical analysis of STP operating data.

  3. Simulation Model for Stochastic Analysis and Performance Evaluation of Steam Generator System of a Thermal Power Plant

    Directory of Open Access Journals (Sweden)

    Yogesh Vora,

    2011-06-01

    Full Text Available This paper presents the stochastic analysis and performance evaluation of turbo generator system of a thermal plant by making the use of performance evaluation using probabilistic approach. The steam generator system of thermal power plant under the research study consists mainly sub-systems boiler, super heater and reheaterarranged in series with two feasible states: working and failed. Failure and repair rates for all the sub-systems are assumed to be constant. Initially transition diagram representing the operational behavior is drawn and then problem formulation is done using Markov approach. Based on the data collection and its analysis for thermal Power Plant, Performance matrix for each subsystem is also developed. Then from these results, availability matrices and graphs of failure and repair rates for maximum availability of each system is analysed and then condition based maintenance decisions are decided.

  4. Hard Sludge Formation in Modern Steam Generators of Nuclear Power Plants Formation, Risks and Mitigation

    Energy Technology Data Exchange (ETDEWEB)

    Strohmer, F.

    2013-07-01

    This article will discuss the physical and chemical reasons for the increased tendency to form hard sludge on the secondary side of modern nuclear steam generators (SG). The mechanism of hard sludge induced denting will be explained. Moreover, advice on operation and maintenance to mitigate hard sludge formation and denting damages will be presented.

  5. Modification of technological control units for superheated steam temperature at 210-MW power units of the Primor'ye Power Plant

    Energy Technology Data Exchange (ETDEWEB)

    V.V. Slesarenko; A.A. Belousov; V.V. Milush [Far East State Engineering University, Vladivostok (Russian Federation)

    2008-06-15

    The results of analysis of operation of the temperature control system for superheated steam at the BKZ-670-140F boilers of the Primor'ye Power Plant (GRES) are presented. The possibility of updating of the injection system to improve the reliability and economic efficiency of power units of electric power plants is considered.

  6. Modification of technological control units for superheated steam temperature at 210-MW power units of the Primor'ye Power Plant

    Science.gov (United States)

    Slesarenko, V. V.; Belousov, A. A.; Milush, V. V.

    2008-06-01

    The results of analysis of operation of the temperature control system for superheated steam at the BKZ-670-140F boilers of the Primor’ye Power Plant (GRES) are presented. The possibility of updating of the injection system to improve the reliability and economic efficiency of power units of electric power plants is considered.

  7. Thermal gain of CHP steam generator plants and heat supply systems

    Science.gov (United States)

    Ziganshina, S. K.; Kudinov, A. A.

    2016-08-01

    Heating calculation of the surface condensate heat recovery unit (HRU) installed behind the BKZ-420-140 NGM boiler resulting in determination of HRU heat output according to fire gas value parameters at the heat recovery unit inlet and its outlet, heated water quantity, combustion efficiency per boiler as a result of installation of HRU, and steam condensate discharge from combustion products at its cooling below condensing point and HRU heat exchange area has been performed. Inspection results of Samara CHP BKZ-420-140 NGM power boilers and field tests of the surface condensate heat recovery unit (HRU) made on the bimetal calorifier base KCk-4-11 (KSk-4-11) installed behind station no. 2 Ulyanovsk CHP-3 DE-10-14 GM boiler were the basis of calculation. Integration of the surface condensation heat recovery unit behind a steam boiler rendered it possible to increase combustion efficiency and simultaneously decrease nitrogen oxide content in exit gases. Influence of the blowing air moisture content, the excess-air coefficient in exit gases, and exit gases temperature at the HRU outlet on steam condensate amount discharge from combustion products at its cooling below condensing point has been analyzed. The steam condensate from HRU gases is offered as heat system make-up water after degasification. The cost-effectiveness analysis of HRU installation behind the Samara CHP BKZ-420-140 NGM steam boiler with consideration of heat energy and chemically purified water economy has been performed. Calculation data for boilers with different heat output has been generalized.

  8. Analysis of the financial impacts to the industrial energy user of using coal or municipal solid waste in a new process-steam-generating plant

    Energy Technology Data Exchange (ETDEWEB)

    1983-10-01

    An analysis is presented of the financial impacts to the industrial energy user of using either coal or MSW in a new process-steam-generating plant. The results of the analysis indicate that the use of coal or solid waste, rather than oil, in a new energy production plant represents an attractive investment. The financial analysis is based on replacing an existing oil-fired plant with a new plant financed via 100-percent debt. The analysis was structured to cover a range of steam demands, different plant ownership and operating structures, and the tax benefits available to these types of plants. Information is also provided on the types of technologies that would be appropriate given the assumed steam demands. In addition, information is provided on available tax benefits in light of recent tax law changes. Nine options for new coal and MSW plants were analyzed, reflecting a matching of technology and energy output to various process steam demands, as well as different ownership and operating structures.

  9. Use of a commercial household steam cleaning system to decontaminate beef and hog carcasses processed by four small or very small meat processing plants in Georgia.

    Science.gov (United States)

    Trivedi, Suvang; Reynolds, A Estes; Chen, Jinru

    2007-03-01

    Small and very small meat-processing facilities in the United States are in need of a pathogen reduction technology that would be both effective and economical. In the present study, the effectiveness of a commercial household steam cleaner for reducing naturally occurring bacterial populations on freshly slaughtered beef and hog carcasses was evaluated in four small or very small meat-processing plants. Three anatomical sites on the right half of each carcass were exposed to a 60-s steam treatment, and the corresponding left half of the carcass remained untreated. Samples were collected from 72 beef and 72 hog carcasses before, immediately after, and 24 h after the steam treatment. The mean populations of total aerobes, coliforms, and Enterobacteriaceae recovered from three anatomical sites on the beef carcasses were 1.88, 1.89, and 1.36 log CFU/cm2, respectively, before the steam treatment, 1.00, 0.71, and 0.52 log CFU/cm2, respectively, immediately after the steam treatment, and 1.10, 0.95, and 0.50 log CFU/cm2, respectively, 24 h after the steam treatment. On hog carcasses, the mean populations of total aerobes, coliforms, and Enterobacteriaceae recovered from the three anatomical sites were 2.50, 2.41, and 1.88 log CFU/cm2, respectively, before the steam treatment, 0.50, 0.94, and 0.21 log CFU/cm2, respectively, immediately after the steam treatment, and 0.91, 1.56, and 0.44 log CFU/cm2, respectively, 24 h after the steam treatment. The steam treatment significantly reduced the total aerobes, coliforms, and Enterobacteriaceae at all three anatomical locations on both types of carcasses (P steam treatment was midline > neck > rump for beef carcasses and belly > jowl > ham for hog carcasses except for the total coliform counts at the midline and neck areas on the beef carcasses. Of the 144 carcasses evaluated, 5 (3.47%) were positive for Salmonella before steam treatment, but all carcasses tested negative for Salmonella after the treatment. Results indicate that

  10. Energy analysis of a combined solid oxide fuel cell with a steam turbine power plant for marine applications

    Science.gov (United States)

    Welaya, Yousri M. A.; Mosleh, M.; Ammar, Nader R.

    2013-12-01

    Strong restrictions on emissions from marine power plants (particularly SO x , NO x ) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and steam turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. The analyzed variant of the combined cycle includes a SOFC operated with natural gas fuel and a steam turbine with a single-pressure waste heat boiler. The calculations were performed for two types of tubular and planar SOFCs, each with an output power of 18 MW. This paper includes a detailed energy analysis of the combined system. Mass and energy balances are performed not only for the whole plant but also for each component in order to evaluate the thermal efficiency of the combined cycle. In addition, the effects of using natural gas as a fuel on the fuel cell voltage and performance are investigated. It has been found that a high overall efficiency approaching 60% may be achieved with an optimum configuration using the SOFC system. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

  11. Energy Analysis of a Combined Solid Oxide Fuel Cell with a Steam Turbine Power Plant for Marine Applications

    Institute of Scientific and Technical Information of China (English)

    Yousri M. A. Welaya; M. Mosleh; Nader R. Ammar

    2013-01-01

    Strong restrictions on emissions from marine power plants (particularly SOx, NOx) will probably be adopted in the near future. In this paper, a combined solid oxide fuel cell (SOFC) and steam turbine fuelled by natural gas is proposed as an attractive option to limit the environmental impact of the marine sector. The analyzed variant of the combined cycle includes a SOFC operated with natural gas fuel and a steam turbine with a single-pressure waste heat boiler. The calculations were performed for two types of tubular and planar SOFCs, each with an output power of 18 MW. This paper includes a detailed energy analysis of the combined system. Mass and energy balances are performed not only for the whole plant but also for each component in order to evaluate the thermal efficiency of the combined cycle. In addition, the effects of using natural gas as a fuel on the fuel cell voltage and performance are investigated. It has been found that a high overall efficiency approaching 60%may be achieved with an optimum configuration using the SOFC system. The hybrid system would also reduce emissions, fuel consumption, and improve the total system efficiency.

  12. Influence of chloride and carbon dioxide on general and crevice corrosion of steam turbine materials for geothermal power plants

    Energy Technology Data Exchange (ETDEWEB)

    Zhang, HaiFeng; Niu, Libin; Oishi, Shuji; Takaku, Hiroshi [Shinshu Univ. (Japan). Faculty of Engineering; Shiokawa, Kunio; Yamashita, Mitsuo [Fuji Electric Advanced Technology Co. Ltd. (Japan); Sakai, Yoshihiro [Fuji Electric Systems Co. Ltd. (Japan)

    2006-09-15

    The influence of chloride and CO{sub 2} on general and crevice corrosion of steam turbine materials for geothermal power plants was investigated in two simulated geothermal waters. The general corrosion rates of the rotor steels with a lower Cr content were accelerated due to the CO{sub 2} in the water, while the corrosion rates of the blade steels with a higher Cr content were controlled mainly by the chloride concentration in the waters. Concerning the crevice corrosion behavior, the galvanic corrosion effects in each of the waters were confirmed for the rotor steels with lower corrosion potentials than those of the blade materials, and almost no difference in corrosion behavior was observed between the two waters tested. Regarding general and crevice corrosion in the two simulated geothermal waters, it was determined that a newly developed rotor material and also an improved heat-treated blade material are promising for actual usage in geothermal power plants. (orig.)

  13. Exergetic analysis of a steam power plant using coal and rice straw in a co-firing process

    Energy Technology Data Exchange (ETDEWEB)

    Restrepo, Alvaro; Miyake, Raphael Guardini; Bazzo, Edson [Federal University of Santa Catarina (UFSC), Dept. of Mechanical Engineering, Florianopolis, SC (Brazil)], e-mails: arestrep@labcet.ufsc.br, miyake@labcet.ufsc.br, ebazzo@emc.ufsc.br; Bzuneck, Marcelo [Tractebel Energia S.A., Capivari de Baixo, SC (Brazil). U.O. Usina Termeletrica Jorge Lacerda C.], e-mail: marcelob@tractebelenergia.com.br

    2010-07-01

    This paper presents an exergetic analysis concerning an existing 50 M We steam power plant, which operates with pulverized coal from Santa Catarina- Brazil. In this power plant, a co-firing rice straw is proposed, replacing up to 10% of the pulverized coal in energy basis required for the boiler. Rice straw has been widely regarded as an important source for bio-ethanol, animal feedstock and organic chemicals. The use of rice straw as energy source for electricity generation in a co-firing process with low rank coal represents a new application as well as a new challenge to overcome. Considering both scenarios, the change in the second law efficiency, exergy destruction, influence of the auxiliary equipment and the greenhouse gases emissions such as CO{sub 2} and SO{sub 2} were considered for analysis. (author)

  14. Thermodynamic Analysis of a Steam Power Plant with Double Reheat and Feed Water Heaters

    OpenAIRE

    2014-01-01

    A steam cycle with double reheat and turbine extraction is presented. Six heaters are used, three of them at high pressure and the other three at low pressure with deaerator. The first and second law analysis for the cycle and optimization of the thermal and exergy efficiencies are investigated. An exergy analysis is performed to guide the thermodynamic improvement for this cycle. The exergy and irreversibility analyses of each component of the cycle are determined. Effects of turbine inlet p...

  15. Estimation of lifespan and economy parameters of steam-turbine power units in thermal power plants using varying regimes

    Science.gov (United States)

    Aminov, R. Z.; Shkret, A. F.; Garievskii, M. V.

    2016-08-01

    The use of potent power units in thermal and nuclear power plants in order to regulate the loads results in intense wear of power generating equipment and reduction in cost efficiency of their operation. We review the methodology of a quantitative assessment of the lifespan and wear of steam-turbine power units and estimate the effect of various operation regimes upon their efficiency. To assess the power units' equipment wear, we suggest using the concept of a turbine's equivalent lifespan. We give calculation formulae and an example of calculation of the lifespan of a steam-turbine power unit for supercritical parameters of steam for different options of its loading. The equivalent lifespan exceeds the turbine's assigned lifespan only provided daily shutdown of the power unit during the night off-peak time. We obtained the engineering and economical indices of the power unit operation for different loading regulation options in daily and weekly diagrams. We proved the change in the prime cost of electric power depending on the operation regimes and annual daily number of unloading (non-use) of the power unit's installed capacity. According to the calculation results, the prime cost of electric power for the assumed initial data varies from 11.3 cents/(kW h) in the basic regime of power unit operation (with an equivalent operation time of 166700 hours) to 15.5 cents/(kW h) in the regime with night and holiday shutdowns. The reduction of using the installed capacity of power unit at varying regimes from 3.5 to 11.9 hours per day can increase the prime cost of energy from 4.2 to 37.4%. Furthermore, repair and maintenance costs grow by 4.5% and by 3 times, respectively, in comparison with the basic regime. These results indicate the need to create special maneuverable equipment for working in the varying section of the electric load diagram.

  16. Influence of the type of working fluid in the lower cycle and superheated steam parameters in the upper cycle on effectiveness of operation of binary power plant

    Directory of Open Access Journals (Sweden)

    Stachel Aleksander A.

    2015-03-01

    Full Text Available In the paper presented have been the results of the analysis of effectiveness of operation of binary power plant consisting of combined two Clausius-Rankine cycles, namely the binary cycle with water as a working fluid in the upper cycle and organic substance as a working fluid in the lower cycle, as well as a single fluid component power plant operating also in line with the C-R cycle for superheated steam, with water as a working fluid. The influence of the parameters of superheated steam in the upper cycle has been assessed as well as the type of working fluid in the lower cycle. The results of calculations have been referred to the single-cycle classical steam power plant operating at the same parameters of superheated steam and the same mass flow rate of water circulating in both cycles. On the basis of accomplished analysis it has been shown that the binary power plant shows a greater power with respect to the reference power plant.

  17. Thermodynamic Analysis of a Steam Power Plant with Double Reheat and Feed Water Heaters

    Directory of Open Access Journals (Sweden)

    M. M. Rashidi

    2014-03-01

    Full Text Available A steam cycle with double reheat and turbine extraction is presented. Six heaters are used, three of them at high pressure and the other three at low pressure with deaerator. The first and second law analysis for the cycle and optimization of the thermal and exergy efficiencies are investigated. An exergy analysis is performed to guide the thermodynamic improvement for this cycle. The exergy and irreversibility analyses of each component of the cycle are determined. Effects of turbine inlet pressure, boiler exit steam temperature, and condenser pressure on the first and second laws' efficiencies are investigated. Also the best turbine extraction pressure on the first law efficiency is obtained. The results show that the biggest exergy loss occurs in the boiler followed by the turbine. The results also show that the overall thermal efficiency and the second law efficiency decrease as the condenser pressure increases for any fixed outlet boiler temperature, however, they increase as the boiler temperature increases for any condenser pressure. Furthermore, the best values of extraction pressure from high, intermediate, and low pressure turbine which give the maximum first law efficiencies are obtained based on the required heat load corresponding to each exit boiler temperature.

  18. Steam oxidation of X20CrMoV121: Comparison of laboratory exposures and in situ exposure in power plants

    DEFF Research Database (Denmark)

    Montgomery, M.; Hansson, A. N.; Vilhelmsen, T.

    2012-01-01

    X20CrMoV121 is a 12% Cr martensitic steel which has been used in power plants in Europe for many decades. Specimens have been removed from superheater tubes to investigate long‐term exposure with respect to steam oxidation. These tubes have been exposed for various durations up to 135 000 h in po...

  19. Influence of heat consumers distribution and flashing vapours effect on steam consumption of evaporation plant of sugar factory

    Directory of Open Access Journals (Sweden)

    A. A. Gromkovskii

    2016-01-01

    Full Text Available The article considered the influence of the heat consumers distribution and the flashing vapours effect juice for multipleevaporator sugar factory on the consumption the main production flow of heat transfer agent – water vapor. The problem of rational distribution of heat transfer agent for of the corps multiple-evaporator is relevant from point of view of energy saving and energysaving heat of the sugar factory. The solution to this problem is advantageously carried out on the basis of quantitative mathematical description of the distribution of vapor on the corps of the evaporation plant. The heat consumers distribution should be based on technical and economic calculation. To solve this problem it is advisable to use a single equation that determines the dependence of the steam flow in the first unit evaporator on the amount of evaporated water and the method of heat consumers distribution for housing. Evaporators sugar factory has two functions – technology and heat, each of which is described by its equation. On the basis of the material and heat balance equations for the realization of the basic functions of the system evaporator written multipleevaporator equations. The solution of this system allows you to obtain the equation of the steam flow and the amount of evaporated water, taking into account the flashing vapours effect. Solution of the system should take into account the accepted design standards of sugar factories. As a result of solving the system of equation is obtained, which allows you to organize and optimize the heat consumers distribution of the corps evaporator. The equation can be used for any number of units evaporator. This equation allows you to assess the efficiency of the evaporation plant of a sugar factory. This is of great practical importance in the modernization of thermal schemes of sugar factories.

  20. High performance steam development

    Energy Technology Data Exchange (ETDEWEB)

    Duffy, T.; Schneider, P. [Solar Turbines Inc., San Diego, CA (United States)

    1995-10-01

    Over 30 years ago U.S. industry introduced the world`s highest temperature (1200{degrees}F at 5000 psig) and most efficient power plant, the Eddystone coal-burning steam plant. The highest alloy material used in the plant was 316 stainless steel. Problems during the first few years of operation caused a reduction in operating temperature to 1100{degrees}F which has generally become the highest temperature used in plants around the world. Leadership in high temperature steam has moved to Japan and Europe over the last 30 years.

  1. Sub-atmospheric disk generators for coal-fired MHD/steam combined cycle power plant

    Energy Technology Data Exchange (ETDEWEB)

    Messerle, H.K.; Fang, Y.; Simpson, S.W.; Marty, S.M. (Sydney Univ. (Australia). School of Electrical Engineering)

    1989-01-01

    A coal fired MHD disk generator in a combined cycle MHD/steam power generation system with a diffuser operating at sub-atmospheric pressure is proposed. The effects of pressure on the performance of a radial outflow MHD disk generator and other system components are analysed. Using a previous study as a reference case, preliminary calculations show that, in such a sub-atmospheric system, improved power station efficiency can be achieved. In addition, operation at reduced values of magnetic field strength would be feasible. Calculations have also been carried out for a 30 MW{sub th} experimental disk generator operating at reduced pressure with a magnetic field strength of 2 T. Flow conditions at sub-atmospheric pressure would provide an improved simulation of a full-scale generator operating at normal pressures. (author).

  2. EARLY ENTRANCE CO-PRODUCTION PLANT-DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    Unknown

    2002-07-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors entered into a Cooperative Agreement with the US Department of Energy (DOE) and the National Energy Technology Laboratory (NETL) to assess the techno-economic viability of building an Early Entrance Co-Production Plant (EECP) in the US to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases. Phase 1 is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase 2 is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase 3 updates the original EECP design based on results from Phase 2, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report covers the period performance from April 1, 2002 through June 30, 2002.

  3. Steam-electric plant air and water quality control data. Summary report for the year ended December 31, 1975, based on FPC Form No. 67

    Energy Technology Data Exchange (ETDEWEB)

    None

    1979-01-01

    Data relating to nationwide impacts of steam-electric power plants on the environment are discussed with regard to growth of the industry; fuel quality; air pollution control; water pollution control; and cost of cooling facilities. Tables are presented to show the following: air quality data aggregated by state and geographic region and by air quality control region; water quality data aggregated by state and geographic region and by water resource region; and individual plant data. (HLW)

  4. Review of Physical Metallurgy of Creep Steel for the Design of Modern Steam Power Plants – Fundamental Theories and Parametric Models

    Directory of Open Access Journals (Sweden)

    V. C. Igwemezie

    2015-12-01

    Full Text Available The need for electricity supply has increased tremendously in recent time thereby necessitating an improvement in the efficiency of steam power plant. A greater efficiency leads to a saving in fuel for a given electricity output with a consequential reduction in the rate at which damage is done to the earth’s environment. This paper looks at the physical metallurgy theories and parametric models that have been the bases in the design of steel for power plant applications.

  5. Steam sauna and mother roasting in Lao PDR: practices and chemical constituents of essential oils of plant species used in postpartum recovery

    Directory of Open Access Journals (Sweden)

    de Boer Hugo J

    2011-12-01

    Full Text Available Abstract Background Fundamental in traditional postpartum recovery in Lao PDR is the use of hotbeds, mother roasting, steam sauna and steam baths. During these treatments medicinal plants play a crucial role, but little has been published about how the treatments are carried out precisely, which species are used, the medicinal properties of these species, and the medicinal efficacy of their chemical constituents. Methods Sixty-five interviews, in 15 rural villages, with women of 4 different ethnic groups were conducted to survey confinement rituals, and postpartum plant use and salience. Essential oils from the main species used were extracted using steam distillation and the main chemical constituents characterized using gas chromatography-mass spectrometry (GC-MS. Results A total of 10 different species were used by three or more of the ethnic groups included in this study. All species were used in steam sauna and bath, but only 3 species were used in hotbed and mother roasting. Essential oils of Amomum villosum, Amomum microcarpum and Blumea balsamifera were found to contain significant amounts of the following terpenes: β-pinene, camphor, bornyl acetate, borneol, linalool, D-limonene, fenchone, terpinen-4-ol and α-terpinene. Conclusions Many of these terpenes have documented antimicrobial and analgesic properties, and some have also synergistic interactions with other terpenes. The mode of application in hotbed and mother roasting differs from the documented mechanisms of action of these terpenes. Plants in these two practices are likely to serve mainly hygienic purposes, by segregating the mother from infection sources such as beds, mats, stools, cloth and towels. Steam sauna medicinal plant use through inhalation of essential oils vapors can possibly have medicinal efficacy, but is unlikely to alleviate the ailments commonly encountered during postpartum convalescence. Steam sauna medicinal plant use through dermal condensation of

  6. Steam generator tube failures

    Energy Technology Data Exchange (ETDEWEB)

    MacDonald, P.E.; Shah, V.N.; Ward, L.W.; Ellison, P.G.

    1996-04-01

    A review and summary of the available information on steam generator tubing failures and the impact of these failures on plant safety is presented. The following topics are covered: pressurized water reactor (PWR), Canadian deuterium uranium (CANDU) reactor, and Russian water moderated, water cooled energy reactor (VVER) steam generator degradation, PWR steam generator tube ruptures, the thermal-hydraulic response of a PWR plant with a faulted steam generator, the risk significance of steam generator tube rupture accidents, tubing inspection requirements and fitness-for-service criteria in various countries, and defect detection reliability and sizing accuracy. A significant number of steam generator tubes are defective and are removed from service or repaired each year. This wide spread damage has been caused by many diverse degradation mechanisms, some of which are difficult to detect and predict. In addition, spontaneous tube ruptures have occurred at the rate of about one every 2 years over the last 20 years, and incipient tube ruptures (tube failures usually identified with leak detection monitors just before rupture) have been occurring at the rate of about one per year. These ruptures have caused complex plant transients which have not always been easy for the reactor operators to control. Our analysis shows that if more than 15 tubes rupture during a main steam line break, the system response could lead to core melting. Although spontaneous and induced steam generator tube ruptures are small contributors to the total core damage frequency calculated in probabilistic risk assessments, they are risk significant because the radionuclides are likely to bypass the reactor containment building. The frequency of steam generator tube ruptures can be significantly reduced through appropriate and timely inspections and repairs or removal from service.

  7. Ukraine Steam Partnership

    Energy Technology Data Exchange (ETDEWEB)

    Gurvinder Singh

    2000-02-15

    The Ukraine Steam Partnership program is designed to implement energy efficiency improvements in industrial steam systems. These improvements are to be made by the private plants and local government departments responsible for generation and delivery of energy to end-users. One of the activities planned under this program was to provide a two-day training workshop on industrial steam systems focusing on energy efficiency issues related to the generation, distribution, and consumption of steam. The workshop was geared towards plant managers, who are not only technically oriented, but are also key decision makers in their respective companies. The Agency for Rational Energy Use and Ecology (ARENA-ECO), a non-governmental, not-for-profit organization founded to promote energy efficiency and environmental protection in Ukraine, in conjunction with the Alliance staff in Kiev sent out invitations to potential participants in all the regions of Ukraine. The purpose of this report is the describe the proceedings from the workshop and provide recommendations from the workshop's roundtable discussion. The workshop was broken down into two main areas: (1) Energy efficient boiler house steam generation; and Energy efficient steam distribution and consumption. The workshop also covered the following topics: (1) Ukrainian boilers; (2) Water treatment systems; (3) A profile of UKRESCO (Ukrainian Energy Services Company); (4) Turbine expanders and electricity generation; (5) Enterprise energy audit basics; and (6) Experience of steam use in Donetsk oblast.

  8. Direct-flash-steam geothermal-power-plant assessment. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Alt, T.E.

    1982-01-01

    The objective of the project was to analyze the capacity and availability factors of an operating direct flash geothermal power plant. The analysis was to include consideration of system and component specifications, operating procedures, maintenance history, malfunctions, and outage rate. The plant studied was the 75 MW(e) geothermal power plant at Cerro Prieto, Mexico, for the years 1973 to 1979. To describe and assess the plant, the project staff reviewed documents, visited the plant, and met with staff of the operating utility. The high reliability and availability of the plant was documented and actions responsible for the good performance were identified and reported. The results are useful as guidance to US utilities considering use of hot water geothermal resources for power generation through a direct flash conversion cycle.

  9. DESIGN AND ANALYSIS OF TURBINE BLADES IN STEAM POWER PLANT SYED

    Directory of Open Access Journals (Sweden)

    ATAUL REHAMAN BASHA

    2014-11-01

    Full Text Available The development of any country directly relates on capital energy consumption. The demand for power generation on the large scale is increasing day by day. Owing to their major contribution towards power production, thermal power plants have a vital role to play in the development of nation. Due to the scarcity of power every power plant needs to be operated at maximum level of efficiency. In case of thermal power plants this applies equally to all its auxiliaries.

  10. Report on Geothermal Power Plant Cost and Comparative Cost of Geothermal and Coal Fired Steam Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    None

    1977-07-01

    This report is to be used by Utah Power and Light Company (UP and L) in making studies of geothermal power plants. The dollars per kilowatt comparison between a geothermal plant and a UP and L coal-fired plant is to be developed. Geothermal gathering system costs and return to owner are to be developed for information.

  11. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers, Volumes 1, 2

    Energy Technology Data Exchange (ETDEWEB)

    Upadhyaya, Belle R. [Univ. of Tennessee, Knoxville, TN (United States); Hines, J. Wesley [Univ. of Tennessee, Knoxville, TN (United States); Lu, Baofu [Univ. of Tennessee, Knoxville, TN (United States)

    2005-06-03

    The overall purpose of this Nuclear Engineering Education Research (NEER) project was to integrate new, innovative, and existing technologies to develop a fault diagnostics and characterization system for nuclear plant steam generators (SG) and heat exchangers (HX). Issues related to system level degradation of SG and HX tubing, including tube fouling, performance under reduced heat transfer area, and the damage caused by stress corrosion cracking, are the important factors that influence overall plant operation, maintenance, and economic viability of nuclear power systems. The research at The University of Tennessee focused on the development of techniques for monitoring process and structural integrity of steam generators and heat exchangers. The objectives of the project were accomplished by the completion of the following tasks. All the objectives were accomplished during the project period. This report summarizes the research and development activities, results, and accomplishments during June 2001 September 2004. Development and testing of a high-fidelity nodal model of a U-tube steam generator (UTSG) to simulate the effects of fouling and to generate a database representing normal and degraded process conditions. Application of the group method of data handling (GMDH) method for process variable prediction. Development of a laboratory test module to simulate particulate fouling of HX tubes and its effect on overall thermal resistance. Application of the GMDH technique to predict HX fluid temperatures, and to compare with the calculated thermal resistance.Development of a hybrid modeling technique for process diagnosis and its evaluation using laboratory heat exchanger test data. Development and testing of a sensor suite using piezo-electric devices for monitoring structural integrity of both flat plates (beams) and tubing. Experiments were performed in air, and in water with and without bubbly flow. Development of advanced signal processing methods using

  12. Electrochemical corrosion behavior of steam turbine materials for geothermal power plants in simulated geothermal waters

    Energy Technology Data Exchange (ETDEWEB)

    Zhang Haofeng [Shinshu Univ. (Japan). Graduate School; Niu Libin; Oishi, Shuji [Shinshu Univ. (Japan). Faculty of Engineering; Takaku, Hiroshi [Shinshu Univ. (Japan). Faculty of Engineering; Naigai Chemical Products Co. (Japan); Shiokawa, Kunio; Yamashita, Mitsuo; Sakai, Yoshihiro [Fuji Electric Advanced Technology Co., Ltd. (Japan)

    2007-08-15

    In order to evaluate the influence of chloride, sulfate and carbon dioxide in water on the electrochemical corrosion behavior of geothermal steam turbine materials, measurements of the anodic polarization and the pitting corrosion potential were conducted in simulated geothermal waters. The corrosion resistance of all materials tested was lowered by an increasing carbon dioxide content in the simulated geothermal waters. Higher chloride concentrations in the waters induced lower corrosion resistance and also lower pitting corrosion potentials for materials with higher chromium contents, suggesting the corrosion behavior was mainly controlled by the chromium content of the materials. The corrosion resistance of 9CrMoV and 13Cr steels was also influenced by the concentration of sulfate in the water. The improved heat-treated 16Cr-4Ni material for turbine blades showed excellent corrosion resistance. In the presence of sulfate, the corrosion reactions are mitigated due to a decreasing concentration of chloride (due to the presence of sulfate) in corrosion pits. (orig.)

  13. Integrity assurance of the secondary side of steam generator in Nuclear Power Plants

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joung Soo; Kim, Hong Pyo; Lim, Yun Soo; Hwang, Seong Sik; Yi, Yong Sun; Kim, Dong Jin; Kim, Sung Soo; Jung, Man Gyo

    2005-09-15

    Residual stresses on the expansion transition regions of steam generator tubes expanded by explosive and hydraulic expansion techniques were measured using several different methods such as strain gauge, XRD, electrolytic polishing, and stress corrosion cracking methods. The SCC method was applied by measuring the cracking time using C-ring specimens to which precisely measured stress had been imposed and comparing the cracking time of the expanded tube specimens in order to estimate the magnitude of residual stress developed on the expansion transition regions. Axial residual stress on the outer surface of both, Inconel 600 and 690 tubes was measured to be mainly compressive, which can not induce circumferential ODSCC on the expansion transition regions. According to SCC test results, SCC was not observed to occur on the expansion transition regions of the expanded model specimen tubes, which means that the residual stresses developed on the expansion transition regions by the explosive and the hydraulic expansion methods are not big enough to induce SCC. However, sludge piled up on the top of tubesheet during operation of NPPs might change the stress state on the expansion transition regions, which can result in occurring SCC.

  14. Thermionic combustor application to combined gas and steam turbine power plants

    Science.gov (United States)

    Miskolczy, G.; Wang, C. C.; Lieb, D. P.; Margulies, A. E.; Fusegni, L. J.; Lovell, B. J.

    A design for the insertion of thermionic converters into the wall of a conventional combustor to produce electricity in a topping cycle is described, and a study for applications in gas and steam generators of 70 and 30 MW is evaluated for engineering and economic feasibility. Waste heat from the thermionic elements is used to preheat the combustor air; the heat absorbed by the elements plus further quenching of the exhaust gases with ammonia is projected to reduce NO(x) emissions to acceptable levels. Schematics, flow diagrams, and components of a computer model for cost projections are provided. It was found that temperatures around the emitters must be maintained above 1,600 K, with maximum efficiency and allowable temperature at 1,800 K, while collectors generate maximally at 950 K, with a corresponding work function of 1.5 eV. Cost sensitive studies indicate an installed price of $475/kW for the topping cycle, with improvements in thermionic converter characteristics bringing the cost to $375/kW at a busbar figure of 500 mills/kWh.

  15. Cumberland Sound Monitoring. Report 2. 1989 Data Collection Report

    Science.gov (United States)

    1991-08-01

    STATEMENT 12b. DISTRIBUTION CODE Approved for public release; distribucion unlimited. 13. ABSTRACT (Maximum 200 words) Water levels, conductivity...temperature, and salinities were measured in the Cumberland Sound study area during January 1989 through December 1989. The data were collected as part of a...long-term study to assess, through comparisons to earlier data collection programs, if changes to the estuarine processes of the study area have

  16. Evaluation of cracking in feedwater piping adjacent to the steam generators in Nine Pressurized Water Reactor Plants

    Energy Technology Data Exchange (ETDEWEB)

    Goldberg, A.; Streit, R.D.; Scott, R.G.

    1980-06-25

    Cracking in ASTM A106-B and A106-C feedwater piping was detected near the inlet to the steam generators in a number of pressurized water reactor plants. We received sections with cracks from nine of the plants with the objective of identifying the cracking mechanism and assessing various factors that might contribute to this cracking. Variations were observed in piping surface irregularities, corrosion-product, pit, and crack morphology, surface elmental and crystal structure analyses, and steel microstructures and mechanical properties. However, with but two exceptions, namely, arrest bands and major surface irregularities, we were unable to relate the extent of cracking to any of these factors. Tensile and fracture toughness (J/sub Ic/ and tearing modulus) properties were measured over a range of temperatures and strain rates. No unusual properties or microstructures were observed that could be related to the cracking problem. All crack surfaces contained thick oxide deposits and showed evidence of cyclic events in the form of arrest bands. Transmission electron microscopy revealed fatigue striations on replicas of cleaned crack surfaces from one plant and possibly from three others. Calculations based on the observed striation spacings gave a value of ..delta..sigma = 150 MPa (22 ksi) for one of the major cracks. The direction of crack propagation was invariably related to the piping surface and not to the piping axis. These two factors are consistent with the proposed concept of thermally induced, cyclic, tensile surface stresses. Although surface irregularities and corrosion pits were sources for crack initiation and corrosion may have contributed to crack propagation, it is proposed that the overriding factor in the cracking problem is the presence of unforeseen cyclic loads.

  17. Physical Metallurgy of Modern Creep-Resistant Steel for Steam Power Plants: Microstructure and Phase Transformations

    Directory of Open Access Journals (Sweden)

    V. C. Igwemezie

    2016-01-01

    Full Text Available The fact that the microstructure of steel depends on its composition and the heat treatment given to it has been heavily exploited in the design of steel for power plant applications. To obtain a steel that can function at the higher temperature where power plants operate without failure for extended life, heat treatment is needed to produce fine and highly stable dispersion of carbides, nitrides, and intermetallic compounds in the microstructure of the material. A significant contribution also comes from solid solution strengthening by substitutional solutes. We review here various types of phases, microstructures, functions, and interacting effects of the various alloying elements in the design of steel for modern power plant application.

  18. Steam explosions-induced containment failure studies for Swiss nuclear power plants

    Energy Technology Data Exchange (ETDEWEB)

    Zuchuat, O.; Schmocker, U. [Swiss Federal Nuclear Safety Inspectorate, Villigen (Switzerland); Esmaili, H.; Khatib-Rahbar, M.

    1998-01-01

    The assessment of the consequences of both in-vessel and ex-vessel energetic fuel-coolant interaction for Beznau (a Westinghouse pressurized water reactor with a large, dry containment), Goesgen (a Siemens/KWU pressurized water reactor with a large, dry containment) and Leibstadt (a General Electric boiling water reactor-6 with a free standing steel, MARK-III containment) nuclear power plants is presented in this paper. The Conditional Containment Failure Probability of the steel containment of these Swiss nuclear power plants is determined based on different probabilistic approaches. (author)

  19. On-Line Monitoring and Diagnostics of the Integrity of Nuclear Plant Steam Generators and Heat Exchangers.

    Energy Technology Data Exchange (ETDEWEB)

    Belle R. Upadhyaya; J. Wesley Hines

    2004-09-27

    The overall purpose of this Nuclear Engineering Education Research (NEER) project was to integrate new, innovative, and existing technologies to develop a fault diagnostics and characterization system for nuclear plant steam generators (SG) and heat exchangers (HX). Issues related to system level degradation of SG and HX tubing, including tube fouling, performance under reduced heat transfer area, and the damage caused by stress corrosion cracking, are the important factors that influence overall plant operation, maintenance, and economic viability of nuclear power systems. The research at The University of Tennessee focused on the development of techniques for monitoring process and structural integrity of steam generators and heat exchangers. The objectives of the project were accomplished by the completion of the following tasks. All the objectives were accomplished during the project period. This report summarizes the research and development activities, results, and accomplishments during June 2001-September 2004. (1) Development and testing of a high-fidelity nodal model of a U-tube steam generator (UTSG) to simulate the effects of fouling and to generate a database representing normal and degraded process conditions. Application of the group method of data handling (GMDH) method for process variable prediction. (2) Development of a laboratory test module to simulate particulate fouling of HX tubes and its effect on overall thermal resistance. Application of the GMDH technique to predict HX fluid temperatures, and to compare with the calculated thermal resistance. (3) Development of a hybrid modeling technique for process diagnosis and its evaluation using laboratory heat exchanger test data. (4) Development and testing of a sensor suite using piezo-electric devices for monitoring structural integrity of both flat plates (beams) and tubing. Experiments were performed in air, and in water with and without bubbly flow. (5) Development of advanced signal

  20. Steam System Efficiency Optimized After J.R. Simplot Fertilizer Plant Receives Energy Assessment

    Energy Technology Data Exchange (ETDEWEB)

    2008-07-01

    This case study describes how the J.R. Simplot company's Don Plant in Pocatello, Idaho, achieved annual savings of $335,000 and 75,000 MMBtu, with a simple payback of 6.5 months, after receiving a DOE Save Energy Now energy assessment.

  1. 78 FR 54569 - Special Local Regulation, Cumberland River, Mile 190.0 to 192.0; Nashville, TN

    Science.gov (United States)

    2013-09-05

    ... necessary to protect participants in the Cumberland River Dragon Boat Festival. Entry into this area is... the Festival. B. Basis and Purpose The Cumberland River Dragon Boat Festival takes place on the... regulation is needed to protect the 1000 participants in the Cumberland River Dragon Boat Festival. The...

  2. Analysis of the temperature distribution of a water wall in the furnace of a supercritical steam power plant

    Energy Technology Data Exchange (ETDEWEB)

    Matsumura, Norihide; Yagi, Nobuyoshi; Shibayama, Motoaki; Hayasaka, Hiroshi

    1988-07-25

    It is one of the important subjects for maintenance and management of modern boilers to establish the technology for estimating the residual life of a water wall tube composing a boiler furnace for a thermal power plant. Various studies on the residual life of material itself for a boiler water-wall tube have so far been in progress, but concerning a temperature of a water wall tube at a particular place inside a boiler furnace, the development of a practical method of analysis estimating the amount of the radiant heat transfer has not so far been progressed. Accordingly, in this report, a practical method for obtaining the temperature distribution of a water wall tube was examined and an idea that the radiant heat ray method was used for the analysis of radiant heat transfer and at the same time, the actual result of the operation was used for steam flow rate, etc. was elaborated and brought into operation. As a result, the following was revealed inter alia: (1) The heat flux became the maximum around the uppermost stages of the burners of the front and rear walls. (2) The temperature of a tube wall became the maximum around the uppermost stages of the burners in the center of the wall. (3) Deviation of the flow distribution affected the wall tube temperature considerably. The above is considered to suggest the adequacy of this analytical method. (12 figs, 9 refs)

  3. Use of Coke Oven Gas during shutdown period of Direct Reduced Iron Plant for Steam Generation: Experimentation and Optimization

    Directory of Open Access Journals (Sweden)

    Harish C. Dalai

    2015-11-01

    Full Text Available Development of any country is largely based on its magnitude of industrial growth. Steel industries in India took a leading role in the world after mid-sixties. During the last five decades, the steel industries all over the world made considerable developments in new methods for reducing iron ore directly to metallic iron for use as commercial scrap substitute in the manufacture of steels. BSL has been producing steel and other products over last two decades and the above process is used in BSL for one decade. Direct reduction is a process, which extracts high metallic solid iron by removing oxygen from iron ore or any other iron oxides without passing through molten stage, i.e. solid state reduction. The product, so formed is known as directly reduced tron (DRI or Sponge Iron. Due to shortage of raw material or any other problem in DRI sections, the DRI section undergoes a temporary short down. During the shutdown period the equipments tend to be idle. To keep the equipment ready for operation as well as to maintain the plants economy an alternate methodology is used in this research. Various operations are: CO gas from Coke Oven, DRI, Steam Generation, and Power Generation.

  4. A simplified Probabilistic Safety Assesment of a Steam-Methane Reforming Hydrogen Production Plant coupled to a High-Temperature Gas Cooled Nuclear Reactor

    OpenAIRE

    Nelson Edelstein, Pamela; Flores Flores, Alain; Francois Lacouture, Juan Luis

    2005-01-01

    A Probabilistic Safety Assessment (PSA) is being developed for a steam-methane reforming hydrogen production plant linked to a High-Temperature Gas Cooled Nuclear Reactor (HTGR). This work is based on the Japan Atomic Energy Research Institute’s (JAERI) High Temperature Test Reactor (HTTR) prototype in Japan. This study has two major objectives: calculate the risk to onsite and offsite individuals, and calculate the frequency of different types of damage to the complex. A simplified HAZOP...

  5. Erosion in Steam General Tubes in Boiler and ID Fans in Coal Fired FBC Power Plant

    Directory of Open Access Journals (Sweden)

    Shaheen Aziz

    2012-01-01

    Full Text Available The FBC (Fluidized Bed Combustion is a technique used to make solid particles behave like fluid and grow very fast for the power generation using low grade coal. Due to its merits, first time this technology has been introduced in Pakistan by installing 3x50 MW power plants at Khanote. Fluidized beds have long been used for the combustion of low-quality, difficult fuels and have become a rapidly developing technology for the clean burning of coal. The FBC Power Plant at Khanote has been facing operational and technical problems, resulting frequently shut down of generation units, consequently facing heavy financial losses. This study reveals that due to the presence of high percentage of silica in the lime stone that are further distributed in the bottom ash, fly ash and re-injection material, the generation tubes in the boiler and wings/blades of ID (Induced Draft fans were eroded. In addition, filter bags were also ruptured; resulting frequent shut down of power plant units.

  6. Early tube leak detection system for steam boiler at KEV power plant

    Directory of Open Access Journals (Sweden)

    Ismail Firas B.

    2016-01-01

    Full Text Available Tube leakage in boilers has been a major contribution to trips which eventually leads to power plant shut downs. Training of network and developing artificial neural network (ANN models are essential in fault detection in critically large systems. This research focusses on the ANN modelling through training and validation of real data acquired from a sub-critical boiler unit. The artificial neural network (ANN was used to develop a compatible model and to evaluate the working properties and behaviour of boiler. The training and validation of real data has been applied using the feed-forward with back-propagation (BP. The right combination of number of neurons, number of hidden layers, training algorithms and training functions was run to achieve the best ANN model with lowest error. The ANN was trained and validated using real site data acquired from a coal fired power plant in Malaysia. The results showed that the Neural Network (NN with one hidden layers performed better than two hidden layer using feed-forward back-propagation network. The outcome from this study give us the best ANN model which eventually allows for early detection of boiler tube leakages, and forecast of a trip before the real shutdown. This will eventually reduce shutdowns in power plants.

  7. 40 CFR 81.59 - Cumberland-Keyser Interstate Air Quality Control Region.

    Science.gov (United States)

    2010-07-01

    ... Quality Control Region. 81.59 Section 81.59 Protection of Environment ENVIRONMENTAL PROTECTION AGENCY... Air Quality Control Regions § 81.59 Cumberland-Keyser Interstate Air Quality Control Region. The Cumberland-Keyser Interstate Air Quality Control Region (Maryland-West Virginia) has been revised to...

  8. Chemical compositions and antioxidant properties of essential oils from nine species of Turkish plants obtained by supercritical carbon dioxide extraction and steam distillation.

    Science.gov (United States)

    Topal, Ummihan; Sasaki, Mitsuru; Goto, Motonobu; Otles, Semih

    2008-01-01

    Chemical compositions and antioxidant activities of essential oils from nine different species of Turkish plants, namely Melissa officinalis L., Rosmarinus officinalis L., Cuminum cyminum L., Piper nigrum L., Lavandula stoechas spp., Foeniculum vulgare, Pimpinella anisum L., Thymus serpyllum and Liquidamber orientalis Mill., were studied. Essential oils were obtained by supercritical carbon dioxide (SCCO2) extraction and steam distillation, and were analyzed by gas chromatography-mass spectrometry. The antioxidant activities of SCCO2 extraction and steam distillation extracts were tested by means of the 1,1-diphenyl-2-picrylhydrazyl (DPPH) assay. Essential oils extracted by SCCO2 and steam distillation showed different compositions in different species. In the DPPH assay, R. officinalis, C. cyminum, P. anisum, T. serpyllum and L. orientalis essential oils obtained by SCCO2 extraction showed higher antioxidant activity than steam distillation extracts, with radical scavenging activities ranging from 87.1 +/- 0.23% to 92.0 +/- 0.34% compared with the butylated hydroxytoluene positive control (91.4 +/- 0.21%).

  9. Materials for higher steam temperatures (up to 600 deg C) in biomass and waste fired plant. A review of present knowledge; Material foer hoegre aangtemperaturer (upp till 600 grader C) i bio- och avfallseldade anlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Staalenheim, Annika; Henderson, Pamela

    2011-02-15

    A goal for the Swedish power industry is to build a demonstration biomass-fired plant with 600 deg C steam data in 2015. Vaermeforsk also has a goal to identify materials that can be used in such a plant. This project involves a survey of present knowledge and published articles concerning materials that are suitable for use in biomass and wastefired plants with steam data up to 600 deg C. The information has been gathered from plants presently in operation, and from field tests previously performed with probes. Plants firing only household waste are excluded. The components considered are waterwalls/furnace walls (affected because of higher steam pressures) and superheaters. Fireside corrosion and steam-side oxidation are dealt with. Candidate materials (or coatings) are suggested and areas for further research have been identified. The purpose of this project is to give state-of-the-art information on what materials could be used in biomass and waste-fired plant to reach a maximum steam temperature of 600 deg C. This report is aimed at suppliers of boilers and materials, energy utility companies and others involved in building new plant with higher steam data. In accordance with the goals of this project: - Materials suitable for use at higher steam temperatures (up to 600 deg C steam) in wood-based biomass and waste-fired plant have been identified. Austenitic stainless steels HR3C, TP 347 HFG and AC66 all have adequate strength, steam-side oxidation and fireside corrosion resistance for use as superheaters. AC66 and HR3C have better steam-side oxidation resistance than TP 347 HFG , but TP 347 HFG has better fireside corrosion resistance. It is recommended that TP 347 HFG be shot-peened on the inside to improve the oxidation resistance if in service with steam temperatures above 580 deg C. - Furnace walls coated with Ni-based alloys or a mixture of Ni- alloy and ceramic show good corrosion resistance at lower temperatures and should be evaluated at higher

  10. Design and thermal analysis of a direct steam generation central-receiver solar thermal power plant

    OpenAIRE

    Garrido Camino, Carlos

    2013-01-01

    Thermo-solar central receiver power plants use radiation coming from the Sun, a clean energy source, to produce electricity. The best locations for this type of installations are the ones between 30º and 40º of latitude, both in the northern and southern hemisphere, what makes Spain to be one of the most suitable and attractive places all over the world for this energy source. However, this technology is not well developed yet comparing to other renewable energy sources such as wind energy or...

  11. A Generalized and Simple Numerical Model to Compute the Feed Water Preheating System for Steam Power Plants

    Directory of Open Access Journals (Sweden)

    Ioana Opriș

    2017-02-01

    Full Text Available A general and simple numerical model is presented to calculate the uncontrolled steam flows extracted from a turbine to preheat the feed-water of a steam generator. For a user-defined technological scheme, a set of clear rules is given to complete the elements of the augmented matrix of the linear system that solves the problem. The model avoids writing of the heat balance equations for each heat exchanger. The steam extractions to the heaters are determined as related to the flow rate at the condenser. A numerical example is given to show the results.

  12. Next Generation Nuclear Plant Steam Generator and Intermediate Heat Exchanger Materials Research and Development Plan

    Energy Technology Data Exchange (ETDEWEB)

    J. K. Wright

    2010-09-01

    DOE has selected the High Temperature Gas-cooled Reactor (HTGR) design for the Next Generation Nuclear Plant (NGNP) Project. The NGNP will demonstrate the use of nuclear power for electricity and hydrogen production. It will have an outlet gas temperature in the range of 900°C and a plant design service life of 60 years. The reactor design will be a graphite moderated, helium-cooled, prismatic or pebble-bed reactor and use low-enriched uranium, Tri-Isotopic (TRISO)-coated fuel. The plant size, reactor thermal power, and core configuration will ensure passive decay heat removal without fuel damage or radioactive material releases during accidents. The NGNP Materials Research and Development (R&D) Program is responsible for performing R&D on likely NGNP materials in support of the NGNP design, licensing, and construction activities. Today’s high-temperature alloys and associated ASME Codes for reactor applications are approved up to 760°C. However, some primary system components, such as the Intermediate Heat Exchanger (IHX) for the NGNP will require use of materials that can withstand higher temperatures. The thermal, environmental, and service life conditions of the NGNP will make selection and qualification of some high-temperature materials a significant challenge. Examples include materials for the core barrel and core internals, such as the control rod sleeves. The requirements of the materials for the IHX are among the most demanding. Selection of the technology and design configuration for the NGNP must consider both the cost and risk profiles to ensure that the demonstration plant establishes a sound foundation for future commercial deployments. The NGNP challenge is to achieve a significant advancement in nuclear technology while at the same time setting the stage for an economically viable deployment of the new technology in the commercial sector soon after 2020. A number of solid solution strengthened nickel based alloys have been considered for

  13. A Geothermal Energy Supported Gas-steam Cogeneration Unit as a Possible Replacement for the Old Part of a Municipal CHP Plant (TEKO

    Directory of Open Access Journals (Sweden)

    L. Böszörményi

    2001-01-01

    Full Text Available The need for more intensive utilization of local renewable energy sources is indisputable. Under the current economic circumstances their competitiveness in comparison with fossil fuels is rather low, if we do not take into account environmental considerations. Integrating geothermal sources into combined heat and power production in a municipal CHP plant would be an excellent solution to this problem. This concept could lead to an innovative type of power plant - a gas-steam cycle based, geothermal energy supported cogeneration unit.

  14. BWR Steam Dryer Alternating Stress Assessment Procedures

    Energy Technology Data Exchange (ETDEWEB)

    Morante, R. J. [Brookhaven National Lab. (BNL), Upton, NY (United States); Hambric, S. A. [Brookhaven National Lab. (BNL), Upton, NY (United States); Ziada, S. [Brookhaven National Lab. (BNL), Upton, NY (United States)

    2016-12-01

    This report presents an overview of Boiling Water Reactor (BWR) steam dryer design; the fatigue cracking failures that occurred at the Quad Cities (QC) plants and their root causes; a history of BWR Extended Power Uprates (EPUs) in the USA; and a discussion of steam dryer modifications/replacements, alternating stress mechanisms on steam dryers, and structural integrity evaluations (static and alternating stress).

  15. EARLY ENTRANCE CO-PRODUCTION PLANT--DECENTRALIZED GASIFICATION COGENERATION TRANSPORTATION FUELS AND STEAM FROM AVAILABLE FEEDSTOCKS

    Energy Technology Data Exchange (ETDEWEB)

    John W. Rich

    2003-06-01

    Waste Processors Management, Inc. (WMPI), along with its subcontractors Texaco Power & Gasification (now ChevronTexaco), SASOL Technology Ltd., and Nexant Inc. entered into a Cooperative Agreement DE-FC26-00NT40693 with the U. S. Department of Energy (DOE), National Energy Technology Laboratory (NETL) to assess the technoeconomic viability of building an Early Entrance Co-Production Plant (EECP) in the United States to produce ultra clean Fischer-Tropsch (FT) transportation fuels with either power or steam as the major co-product. The EECP design includes recovery and gasification of low-cost coal waste (culm) from physical coal cleaning operations and will assess blends of the culm with coal or petroleum coke. The project has three phases. Phase I is the concept definition and engineering feasibility study to identify areas of technical, environmental and financial risk. Phase II is an experimental testing program designed to validate the coal waste mixture gasification performance. Phase III updates the original EECP design based on results from Phase II, to prepare a preliminary engineering design package and financial plan for obtaining private funding to build a 5,000 barrel per day (BPD) coal gasification/liquefaction plant next to an existing co-generation plant in Gilberton, Schuylkill County, Pennsylvania. The current report covers the period performance from January 1, 2003 through March 31, 2003. Phase I Task 6 activities of Preliminary Site Analysis were documented and reported as a separate Topical Report on February 2003. Most of the other technical activities were on hold pending on DOE's announcement of the Clean Coal Power Initiative (CCPI) awards. WMPI was awarded one of the CCPI projects in late January 2003 to engineer, construct and operate a first-of-kind gasification/liquefaction facility in the U.S. as a continued effort for the current WMPI EECP engineering feasibility study. Since then, project technical activities were focused on: (1

  16. Scale Model Test and Transient Analysis of Steam Injector Driven Passive Core Injection System for Innovative-Simplified Nuclear Power Plant

    Science.gov (United States)

    Ohmori, Shuichi; Narabayashi, Tadashi; Mori, Michitsugu

    A steam injector (SI) is a simple, compact and passive pump and also acts as a high-performance direct-contact compact heater. This provides SI with capability to serve also as a direct-contact feed-water heater that heats up feed-water by using extracted steam from turbine. Our technology development aims to significantly simplify equipment and reduce physical quantities by applying "high-efficiency SI", which are applicable to a wide range of operation regimes beyond the performance and applicable range of existing SIs and enables unprecedented multistage and parallel operation, to the low-pressure feed-water heaters and emergency core cooling system of nuclear power plants, as well as achieve high inherent safety to prevent severe accidents by keeping the core covered with water (a severe accident-free concept). This paper describes the results of the scale model test, and the transient analysis of SI-driven passive core injection system (PCIS).

  17. Automatic control of plants of direct steam generation with cylinder-parabolic solar collectors; Control automatico de plantas de generacion directa de vapor con colectores solares cilindro-parabolicos

    Energy Technology Data Exchange (ETDEWEB)

    Valenzuela Gutierrez, L.

    2008-07-01

    The main objective of this dissertation has been the contributions to the operation in automatic mode of a new generation of direct steam generation solar plants with parabolic-trough collectors. The dissertation starts introducing the parabolic-trough collectors solar thermal technology for the generation of process steam or steam for a Rankine cycle in the case of power generation generation, which is currently the most developed and commercialized technology. Presently, the parabolic-trough collectors technology is based on the configuration known as heat-exchanger system, based in the use of a heat transfer fluid in the solar field which is heated during the recirculation through the absorber tubes of the solar collectors, transferring later on the that thermal energy to a heat-exchanger for steam generation. Direct steam generation in the absorber tubes has always been shown as an ideal pathway to reduce generation cost by 15% and increase conversion efficiency by 20% (DISS, 1999). (Author)

  18. On line chemical analyzers for high purity steam and water, applied to steam power plants; Analizadores quimicos en linea para agua y vapor de alta pureza, aplicados a centrales termoelectricas

    Energy Technology Data Exchange (ETDEWEB)

    Diaz Perez, Ruth [Instituto de Investigaciones Electricas, Cuernavaca (Mexico)

    1989-12-31

    This article presents a general overview of the advances in the subject of on line analyzers of chemical parameters for high purity water and steam and specifies which ones are commercially available. Also are mentioned besides, the criteria nowadays applied for the selection of the sites for sample grabbing and the analysis that is necessary to perform in each point, depending on the power plant type and the treatment administered (phosphates-Ph coordinated or AVT treatment). [Espanol] El articulo presenta un panorama general de los avances que en materia de analizadores de parametros quimicos en linea para agua y vapor de alta pureza, y especifica cuales estan disponibles en forma comercial. Se citan, ademas los criterios que se aplican actualmente para seleccionar los puntos de toma de muestra y los analisis que es necesario efectuar en cada punto, dependiendo del tipo de central y del tratamiento que se le administre (fosfatos-pH coordinado o tratamiento AVT).

  19. Steam Turbines

    Science.gov (United States)

    1981-01-01

    Turbonetics Energy, Inc.'s steam turbines are used as power generating systems in the oil and gas, chemical, pharmaceuticals, metals and mining, and pulp and paper industries. The Turbonetics line benefited from use of NASA research data on radial inflow steam turbines and from company contact with personnel of Lewis Research Center, also use of Lewis-developed computer programs to determine performance characteristics of turbines.

  20. Coupling of high temperature nuclear reactor with chemical plant by means of steam loop with heat pump

    Directory of Open Access Journals (Sweden)

    Kopeć Mariusz

    2017-01-01

    Full Text Available High temperature nuclear reactors (HTR can be used as an excellent, emission-free source of technological heat for various industrial applications. Their outlet helium temperature (700°-900°C allows not only for heat supply to all processes below 600°C (referred to as “steam class”, but also enables development of clean nuclear-assisted hydrogen production or coal liquefaction technologies with required temperatures up to 900°C (referred to as “chemical class”. This paper presents the results of analyses done for various configurations of the steam transport loop coupled with the high-temperature heat pump designed for “chemical class” applications. The advantages and disadvantages as well as the key issues are discussed in comparison with alternative solutions, trying to answer the question whether the system with the steam loop and the hightemperature heat pump is viable and economically justified.

  1. Design of a Programmable System for Failure Modes and Effect Analysis of Steam-Power Plant Based on the Fault Tree Analysis

    Directory of Open Access Journals (Sweden)

    Dr. Zuhair I. Ahmad Al- Dauod

    2005-01-01

    Full Text Available In this paper, the system of the power plant has been investigated as a special type of industrial systems, which has a significant role in improving societies since the electrical energy has entered all kinds of industries, and it is considered as the artery of modern life. The aim of this research is to construct a programming system, which could be used to identify the most important failure modes that are occur in a steam type of power plants. Also the effects and reasons of each failure mode could be analyzed through the usage of this programming system reaching to the basic events (main reasons that causing each failure mode. The construction of this system for FMEA is depending on the logical relationships of the fault tree analysis for the systems that contained in the power station. The designing of such system could be used as an assistance tool for the specialist user (the power engineer in identifying of all reasons and effects for any type of failures. So this is help to fastening the repairing operation of the identified failure mode to improve the efficiency of operating system as represented by the maintainability, which is a function of system reliability. The selection of the steam type of power generation systems for the application of this study, because this type is the most common type of Iraqi power plants. While such the designed system could be programmed to be use in another types of industrial systems.

  2. District heating and cooling systems for communities through power-plant retrofit and distribution network. Volume 2. Tasks 1-3. Final report. [Downtown Toledo steam system

    Energy Technology Data Exchange (ETDEWEB)

    Watt, J.R.; Sommerfield, G.A.

    1979-08-01

    Each of the tasks is described separately: Task 1 - Demonstration Team; Task 2 - Identify Thermal Energy Source(s) and Potential Service Area(s); and Task 3 - Energy Market Analysis. The purpose of the project is to establish and implement measures in the downtown Toledo steam system for conserving scarce fuel supplies through cogeneration, by retrofit of existing base- or intermediate-loaded electric-generating plants to provide for central heating and cooling systems, with the ultimate purpose of applying the results to other communities. For Task 1, Toledo Edison Company has organized a Demonstration Team (Battelle Columbus Laboratories; Stone and Webster; Ohio Dept. of Energy; Public Utilities Commission of Ohio; Toledo Metropolitan Area Council of Governments; and Toledo Edison) that it hopes has the expertise to evaluate the technical, legal, economic, and marketing issues related to the utilization of by-product heat from power generation to supply district heating and cooling services. Task 2 gives a complete technical description of the candidate plant(s), its thermodynamic cycle, role in load dispatch, ownership, and location. It is concluded that the Toledo steam distribution system can be the starting point for developing a new district-heating system to serve an expanding market. Battelle is a member of the team employed as a subcontractor to complete the energy market analysis. The work is summarized in Task 3. (MCW)

  3. TOC in water/steam cycles. Zittau Colloquium on Power Plant Chemistry; TOC in Wasser/Dampf-Kreislaeufen. Zittauer Kraftwerkschemisches Kolloquium

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2000-07-01

    Many power plants use treated surface water as boiler feedwater and have difficulties in keeping within the limits for organic substances in feedwater (TOC < 200 ppb) or acid conductivity in steam condensate (< 0.2 {mu}S/cm). The characteristics of surface water and the role of organic substances in boiler feedwater are explained and discussed. [German] Viele Kraftwerke bereiten fuer die Erzeugung von Kesselspeisewasser Oberflaechenwasser auf und haben Probleme, die Richtlinien fuer organische Stoffe im Speisewasser (TOC < 200 ppb) oder Saeure-Leitfaehigkeit in Dampfkondensaten (< 0,2 {mu}S/cm) einzuhalten. Die besonderen Eigenschaften von Oberflaechenwaessern und die Bedeutung organischer Stoffe in Kesselspeisewasser werden erlaeutert und diskutiert. (orig.)

  4. Energy Conversion Alternatives Study (ECAS), Westinghouse phase 1. Volume 7: Metal vapor Rankine topping-steam bottoming cycles. [energy conversion efficiency in electric power plants

    Science.gov (United States)

    Deegan, P. B.

    1976-01-01

    Adding a metal vapor Rankine topper to a steam cycle was studied as a way to increase the mean temperature at which heat is added to the cycle to raise the efficiency of an electric power plant. Potassium and cesium topping fluids were considered. Pressurized fluidized bed or pressurized (with an integrated low-Btu gasifier) boilers were assumed. Included in the cycles was a pressurizing gas turbine with its associated recuperator, and a gas economizer and feedwater heater. One of the ternary systems studied shows plant efficiency of 42.3% with a plant capitalization of $66.7/kW and a cost of electricity of 8.19 mills/MJ (29.5 mills/kWh).

  5. Coastal Vulnerability Index (CVI) dataset for Cumberland Island National Seashore (cuis_shore)

    Data.gov (United States)

    U.S. Geological Survey, Department of the Interior — A coastal vulnerability index (CVI) was used to map the relative vulnerability of the coast to future sea-level rise within Cumberland Island National Seashore in...

  6. Methane production from steam-exploded bamboo.

    Science.gov (United States)

    Kobayashi, Fumihisa; Take, Harumi; Asada, Chikako; Nakamura, Yoshitoshi

    2004-01-01

    To convert unutilized plant biomass into a useful energy source, methane production from bamboo was investigated using a steam explosion pretreatment. Methane could not be produced from raw bamboo but methane production was enhanced by steam explosion. The maximum amount of methane produced, i.e., about 215 ml, was obtained from 1 g of exploded bamboo at a steam pressure of 3.53 MPa and a steaming time of 5 min. A negative correlation between the amount of methane produced and the amount of Klason lignin was observed in the methane fermentation of steam-exploded bamboo.

  7. Analysis on the Current Status of Chemical Decontamination Technology of Steam Generators in the Oversea Nuclear Power Plants (NPPs)

    Energy Technology Data Exchange (ETDEWEB)

    Yoon, Taebin; Kim, Sukhoon; Kim, Juyoul; Kim, Juyub; Lee, Seunghee [FNC Technology Co. Ltd., Yongin (Korea, Republic of)

    2015-10-15

    The steam generators in Hanbit Unit 3 and 4 are scheduled to be replaced in 2018 and 2019, respectively. Nevertheless, the wastes from the dismantled steam generators are currently just on-site stored in the NPP because there are no disposal measures for the waste and lack of the decontamination techniques for large-sized metallic equipment. In contrast, in the oversea NPPs, there are many practical cases of chemical decontamination not only for oversized components in the NPPs such as reactor pressure vessel and steam generator, but also for major pipes. Chemical decontamination technique is more effective in decontaminating the components with complicated shape compared with mechanical one. Moreover, a high decontamination factor can be obtained by using strong solvent, and thereby most of radionuclides can be removed. Due to these advantages, the chemical decontamination has been used most frequently for operation of decontaminating the large-sized equipment. In this study, an analysis on the current status of chemical decontamination technique used for the steam generators of the foreign commercial NPPs was performed. In this study, the three major chemical decontamination processes were reviewed, which are applied to the decommissioning process of the steam generators in the commercial NPPs of the United States, Germany, and Belgium. The three processes have the different features in aspect of solvent, while those are based in common on the oxidation and reduction between the target metal surface and solvents. In addition, they have the same goals for improving the decontamination efficiency and decreasing the amount of the secondary waste generation. Based on the analysis results on component sub-processes and major advantages and disadvantages of each process, Table 2 shows the key fundamental technologies for decontamination of the steam generator in Korea and the major considerations in the development process of each technology. It is necessary to prepare

  8. Comprehensive Evaluation of a CO2-Capturing NOx-Free Repowering System with Utilization of Middle Pressure Steam in a Thermal Power Plant

    Science.gov (United States)

    Sik Pak, Pyong

    A CO2-capturing NOx-free H2O turbine power generation system is proposed in which middle pressure steam produced in a thermal power plant is utilized to increase generated power when demand for electricity is large. The proposed system can capture all the generated CO2 based on the oxygen combustion method and emits no NOx, so that it causes no urban and global environmental problems. A combined cycle power generation system with 200MW gas turbine power output is adopted as an example of a thermal power plant. It was assumed that 32 t/h of steam with 25kg/cm2 pressure produced at waste heat recovery boiler was utilized in the proposed system.It has been shown through simulation study that increase of power output by 11.8MW or 4.51% of the rated output is possible with no efficiency decrease. The amount of CO2 reduction is estimated to be 19600t/y.The unit cost of generated power is estimated to be 8.38yen/kWh, annual gross profit of the proposed system 271 million yen, depreciation year 4.87, and thus the proposed system is estimated to be economically feasible.

  9. Combined thermal storage pond and dry cooling tower waste heat rejection system for solar-thermal steam-electric power plants. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Guyer, E.C.; Bourne, J.G.; Brownell, D.L.; Rose, R.M.

    1979-02-28

    The thermal performance and economics of the combined thermal storage pond and dry cooling tower waste heat rejection system concept for solar-thermal steam-electric plants have been evaluated. Based on the computer simulation of the operation of southwest-sited solar-thermal plants, it has been determined that the combined pond-tower concept has significant cost and performance advantages over conventional dry cooling systems. Use of a thermal storage pond as a component of the dry cooling system allows a significant reduction in the required dry cooling heat exchange capacity and the associated parasitic power consumption. Importantly, it has been concluded that the combined pond-tower dry cooling system concept can be employed to economically maintain steam condensing temperatures at levels normally achieved with conventional evaporative cooling systems. An evaluation of alternative thermal storage pond design concepts has revealed that a stratified vertical-flow cut-and-fill reservoir with conventional membrane lining and covering would yield the best overall system performance at the least cost.

  10. Advanced technologies on steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Sakata, Kaoru; Nakamura, Yuuki [Mitsubishi Heavy Industry Co., Takasago (Japan); Nakamori, Nobuo; Mizutani, Toshiyuki; Uwagawa, Seiichi; Saito, Itaru [Mitsubishi Heavy Industry Co., Kobe (Japan); Matsuoka, Tsuyoshi [Mitsubishi Heavy Industry Co., Yokohama (Japan)

    1997-12-31

    The thermal-hydraulic tests for a horizontal steam generator of a next-generation PWR (New PWR-21) were performed. The purpose of these tests is to understand the thermal-hydraulic behavior in the secondary side of horizontal steam generator during the plant normal operation. A test was carried out with cross section slice model simulated the straight tube region. In this paper, the results of the test is reported, and the effect of the horizontal steam generator internals on the thermalhydraulic behavior of the secondary side and the circulation characteristics of the secondary side are discussed. (orig.). 3 refs.

  11. Comparative biochemical analysis after steam pretreatment of lignocellulosic agricultural waste biomass from Williams Cavendish banana plant (Triploid Musa AAA group).

    Science.gov (United States)

    Kamdem, Irénée; Jacquet, Nicolas; Tiappi, Florian Mathias; Hiligsmann, Serge; Vanderghem, Caroline; Richel, Aurore; Jacques, Philippe; Thonart, Philippe

    2015-11-01

    The accessibility of fermentable substrates to enzymes is a limiting factor for the efficient bioconversion of agricultural wastes in the context of sustainable development. This paper presents the results of a biochemical analysis performed on six combined morphological parts of Williams Cavendish Lignocellulosic Biomass (WCLB) after steam cracking (SC) and steam explosion (SE) pretreatments. Solid (S) and liquid (L) fractions (Fs) obtained from SC pretreatment performed at 180°C (SLFSC180) and 210°C (SLFSC210) generated, after diluted acid hydrolysis, the highest proportions of neutral sugar (NS) contents, specifically 52.82 ± 3.51 and 49.78 ± 1.39%w/w WCLB dry matter (DM), respectively. The highest proportions of glucose were found in SFSC210 (53.56 ± 1.33%w/w DM) and SFSC180 (44.47 ± 0.00%w/w DM), while the lowest was found in unpretreated WCLB (22.70 ± 0.71%w/w DM). Total NS content assessed in each LF immediately after SC and SE pretreatments was less than 2%w/w of the LF DM, thus revealing minor acid autohydrolysis consequently leading to minor NS production during the steam pretreatment. WCLB subjected to SC at 210 °C (SC210) generated up to 2.7-fold bioaccessible glucan and xylan. SC and SE pretreatments showed potential for the deconstruction of WCLB (delignification, depolymerization, decrystallization and deacetylation), enhancing its enzymatic hydrolysis. The concentrations of enzymatic inhibitors, such as 2-furfuraldehyde and 5-(hydroxymethyl)furfural from LFSC210, were the highest (41 and 21 µg ml(-1), respectively). This study shows that steam pretreatments in general and SC210 in particular are required for efficient bioconversion of WCLB. Yet, biotransformation through biochemical processes (e.g., anaerobic digestion) must be performed to assess the efficiency of these pretreatments.

  12. 78 FR 5483 - Endangered and Threatened Wildlife and Plants; Permit Applications

    Science.gov (United States)

    2013-01-25

    .... Alasmidonta atropurpurea......... Cumberland elktoe. Cyprogenia stegaria Fanshell. Dromus dromas Dromedary... sturgeon, cumberland elktoe, fanshell, dromedary pearlymussel, cumberland combshell, oyster mussel,...

  13. Revamping of Temperature and Pressure Reduction Interlock in High Pressure Steam System of Large Chemical Plant%大型化工厂高压蒸汽减温减压联锁改造

    Institute of Scientific and Technical Information of China (English)

    乜春晖; 何魁邦; 杨德林

    2014-01-01

    Describe the importance of stability of both high and medium pressure steam systems in large chemical plant . After modifying the steam control system and interlock logic drawbacks in the design ,the foundation for smooth delivery of steam power is laid ,continuity of the production in chemical plant is guaranteed ,and economic benefits are improved .%阐述了调解大型化工厂高压蒸汽与中压过热蒸汽的稳定对于化工企业的重要性。修改设计存在的蒸汽调解及联锁逻辑弊端,为蒸汽动力的平稳输送奠定了基础,保证了化工企业的生产连续性,提高了经济效益。

  14. Boiler and steam generator corrosion: Fossil fuel power plants. (Latest citations from the NTIS bibliographic database). Published Search

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-11-01

    The bibliography contains citations concerning corrosion effects, mechanisms, detection, and inhibition in fossil fuel fired boilers. Fluidized bed combustors and coal gasification are included in the applications. The citations examine hot corrosion, thermal mechanical degradation, and intergranular oxidation corrosion studies performed on the water side and hot gas side of heat exchanger tubes and support structures. Coatings and treatment of material to inhibit corrosion are discussed. Corrosion affecting nuclear powered steam generators is examined in a separate bibliography. (Contains 50-250 citations and includes a subject term index and title list.) (Copyright NERAC, Inc. 1995)

  15. High temperature corrosion in straw-fired power plants: Influence of steam/metal temperature on corrosion rates for TP347H

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Biede, O; Larsen, OH

    2002-01-01

    The corrosion in straw-fired boilers has been investigated at various straw-fired power plants in Denmark. Water/air-cooled probes, a test superheater and test sections removed from the actual superheater have been utilised to characterise corrosion and corrosion rates. This paper describes...... the corrosion rates measured for the TP347H type steel. The corrosion morphology at high temperature consists of grain boundary attack and selective attack of chromium. The corrosion rate increases with calculated metal temperature (based on steam temperature), however there is great variation within...... these results. In individual superheaters, there are significant temperature variations i.e. higher temperature in middle banks compared to the outer banks, higher temperature in leading tubes, which have a high impact on corrosion. In a single loop the assumption that heat uptake (and heat flux) is linear...

  16. High temperature corrosion in straw-fired power plants: Influence of steam/metal temperature on corrosion rates for TP347H

    DEFF Research Database (Denmark)

    Montgomery, Melanie; Biede, O; Larsen, OH

    2002-01-01

    The corrosion in straw-fired boilers has been investigated at various straw-fired power plants in Denmark. Water/air-cooled probes, a test superheater and test sections removed from the actual superheater have been utilised to characterise corrosion and corrosion rates. This paper describes...... the corrosion rates measured for the TP347H type steel. The corrosion morphology at high temperature consists of grain boundary attack and selective attack of chromium. The corrosion rate increases with calculated metal temperature (based on steam temperature), however there is great variation within...... these results. In individual superheaters, there are significant temperature variations i.e. higher temperature in middle banks compared to the outer banks, higher temperature in leading tubes, which have a high impact on corrosion. In a single loop the assumption that heat uptake (and heat flux) is linear...

  17. Economic and Thermodynamic Analysis for Preliminary Design of Dry Steam Geothermal Power Plant (GPP) with Multifarious Gas Removal System (GRS) in Kamojang, West Java, Indonesia

    Science.gov (United States)

    Damar Pranadi, Aloysius; Sihana; Suryopratomo, Kutut; Rahmatika Salis, Fiki

    2016-09-01

    Indonesia has great number of geothermal potential separated by two kind of potential, 16.13 GW for high enthalpy and 7.88 GW for low enthalpy speculative resources [4]. In the end of 2013, Ministry of Energy and Mineral Resources stated that Geothermal Power Plant (GPP) in Indonesia have been built about 1.34 GW in capacity and wanted to seriously develop geothermal potential up to 6.64 GW by 2025 [8]. Cost is one of famous obstacle in Indonesia's GPP Development. To reduce grand total cost of GPP, this paper will present the relation between thermodynamic and economic analysis in purpose to find the most economical gas removal system in GPP. By gleaning data at Kamojang Steam Field on behalf of PT Pertamina Geothermal Energy, this study will thermodynamically analyze and calculate a GPP preliminary design with software, named as Cycle Tempo 5.0. In additional, writers create motive steam calculator (based on C++ language) to enhance thermodynamic analysis for gas removal system (GRS) and adapted the results in Cycle Tempo 5.0. After thermodynamic analysis has been done, economic study will be undertaken by Net Present Value Analysis to compare the utilization cost of three different GRS and find which kind of GRS is more economical for nearly 30 years operation. For the result, Dual LRVP has higher performance than the others, spend less utilization cost and more economical for nearly 30 years operation. Moreover, the economic analysis for replacement of gas removal system shown in this paper too. In conclusion, GPP with Dual LRVP is proper to be developed in the future Geothermal Power Plant or to replace the existing GRS in some existing GPP in Indonesia.

  18. Strategic maintenance plan for Cernavoda steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Cicerone, T. [CNE-PROD, Cernavoda (Romania); Dhar, D.; VandenBerg, J.P. [Babcock and Wilcox (Canada)

    2002-07-01

    Steam generators are among the most important pieces of equipment in a nuclear power plant. They are required full time during the plant operation and obviously no redundancy exists. Past experience has shown that those utilities which implemented comprehensive steam generator inspection and maintenance programs and strict water chemistry controls, have had good steam generator performance that supports good overall plant performance. The purpose of this paper is to discuss a strategic Life Management and Operational-monitoring program for the Cernavoda steam generators. The program is first of all to develop a base of expertise for the management of the steam generator condition; and that is to be supported by a program of actions to be accomplished over time to assess their condition, to take measures to avoid degradation and to provide for inspections, cleaning and modifications as necessary. (author)

  19. Research and Development of Heat-Resistant Materials for Advanced USC Power Plants with Steam Temperatures of 700 °C and Above

    Directory of Open Access Journals (Sweden)

    Fujio Abe

    2015-06-01

    Full Text Available Materials-development projects for advanced ultra-supercritical (A-USC power plants with steam temperatures of 700 °C and above have been performed in order to achieve high efficiency and low CO2 emissions in Europe, the US, Japan, and recently in China and India as well. These projects involve the replacement of martensitic 9%−12% Cr steels with nickel (Ni-base alloys for the highest temperature boiler and turbine components in order to provide sufficient creep strength at 700°C and above. To minimize the requirement for expensive Ni-base alloys, martensitic 9%−12% Cr steels can be applied to the next highest temperature components of an A-USC power plant, up to a maximum of 650°C. This paper comprehensively describes the research and development of Ni-base alloys and martensitic 9%−12% Cr steels for thick section boiler and turbine components of A-USC power plants, mainly focusing on the long-term creep-rupture strength of base metal and welded joints, strength loss in welded joints, creep-fatigue properties, and microstructure evolution during exposure at elevated temperatures.

  20. Techno-economic performance evaluation of direct steam generation solar tower plants with thermal energy storage systems based on high-temperature concrete and encapsulated phase change materials

    Science.gov (United States)

    Guédez, R.; Arnaudo, M.; Topel, M.; Zanino, R.; Hassar, Z.; Laumert, B.

    2016-05-01

    Nowadays, direct steam generation concentrated solar tower plants suffer from the absence of a cost-effective thermal energy storage integration. In this study, the prefeasibility of a combined sensible and latent thermal energy storage configuration has been performed from thermodynamic and economic standpoints as a potential storage option. The main advantage of such concept with respect to only sensible or only latent choices is related to the possibility to minimize the thermal losses during system charge and discharge processes by reducing the temperature and pressure drops occurring all along the heat transfer process. Thermodynamic models, heat transfer models, plant integration and control strategies for both a pressurized tank filled with sphere-encapsulated salts and high temperature concrete storage blocks were developed within KTH in-house tool DYESOPT for power plant performance modeling. Once implemented, cross-validated and integrated the new storage model in an existing DYESOPT power plant layout, a sensitivity analysis with regards of storage, solar field and power block sizes was performed to determine the potential impact of integrating the proposed concept. Even for a storage cost figure of 50 USD/kWh, it was found that the integration of the proposed storage configuration can enhance the performance of the power plants by augmenting its availability and reducing its levelized cost of electricity. As expected, it was also found that the benefits are greater for the cases of smaller power block sizes. Specifically, for a power block of 80 MWe a reduction in levelized electricity costs of 8% was estimated together with an increase in capacity factor by 30%, whereas for a power block of 126 MWe the benefits found were a 1.5% cost reduction and 16% availability increase.

  1. Development of Steam Turbine Inlet Control Valve for Supercritical Pressure at Siemens Industrial Turbomachinery AB

    OpenAIRE

    Sors, Felix; Holm, Patrik

    2010-01-01

    The development in the steam turbine business is heading for applications with much higher steam parameters since this enables a raised efficiency. Steam parameters refer to the pressure and the temperature of the steam. The aim of this study was to generate concepts for steam turbine inlet control valves designed for higher pressure and temperature in comparison with the present design. Future steam power plants using solar energy, based on tower technology, request this kind of performance ...

  2. Steam Drum Design for Direct Steam Generation

    OpenAIRE

    Willwerth, Lisa; Müller, Svenja; Krüger, Joachim; Succo, Manuel; Feldhoff, Jan Fabian; Tiedemann, Jörg; Pandian, Juvaraj; Krüger, Dirk; Hennecke, Klaus

    2016-01-01

    For the direct steam generation in solar fields, the recirculation concept has been demonstrated in several installations. Water masses in the solar field vary during transient phases, such as passing clouds. The volume of the steam drum can serve as a buffer during such transients by taking in excess water and providing water storage. The saturated steam mass flow to the superheating section or the consumer can be maintained almost constant during short transients; therefore the steam drum p...

  3. Guidelines for water and steam adapted to Swedish energy plants; Riktvaerden foer vatten och aanga anpassade till svenska energianlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats [Hellman Vatten AB, Haegersten (Sweden)

    2006-02-15

    The project summons a revision of the Swedish Cycle Chemistry Guidelines with the purpose to create guidelines that are more explicit and thereby easier to adapt to in daily operations. The objective in general has not been to tighten the limiting values; some are stricter but some others are less strict. The boilers of today are usually fed with demineralised water as make-up water which has been reflected in the guidelines. In this project consideration has been taken upon the fact that many boilers, mostly industrial, have been in operation for many years according to old guidelines, without problems. In these cases the boilers may very well continue to operate without any costly reinvestments due to the new guidelines. The most important revisions in the guidelines are: Action levels have been introduced for the core parameters in the water-steam cycle. With action levels the operators will have some guidance to correct deviations in the cycle chemistry. The action levels are progressive in the sense that the more serious deviation from the guidelines, the shorter time to correct the problem. Guidelines for boilers up to 6.0 MPa operating on softened make-up water have been adjusted slightly and introduced with action levels. New guidelines for boilers with demineralised make-up water have been compiled. Within the project group there is a consensus that demineralised make-up water is preferable even for low pressure boilers. Varying chemistry regimes are used in the industry today. This report gives guidelines for the three dominating in Sweden; All Volatile Treatment (AVT), Caustic Treatment and Phosphate Treatment. Cation conductivity is a core parameter for supervision of steam quality for turbine operation, and in all international guidelines cation conductivity is included. However, the cation conductivity can rise above limits if organic dosing agents are used. This may be accepted as long as the pH-value is within the specifications and it can be shown

  4. Recent trends in repair and refurbishing of steam turbine components

    Indian Academy of Sciences (India)

    A K Bhaduri; S K Albert; S K Ray; P Rodriguez

    2003-06-01

    The repair and refurbishing of steam generator components is discussed from the perspective of repair welding philosophy including applicable codes and regulations. Some case histories of repair welding of steam generator components are discussed with special emphasis on details of repair welding of cracked steam turbine blades and shrouds in some of the commercial nuclear power plants using procedures developed.

  5. 压水堆核电厂蒸汽管道内湿蒸汽的流动特性研究%Study on Flow Characteristics of Wet Steam Flowing Through Steam Pipeline in PWR Nuclear Power Plant

    Institute of Scientific and Technical Information of China (English)

    李勇; 许家通

    2015-01-01

    推导了湿蒸汽在等截面直管道稳定流动的动量方程,结合能量方程和连续性方程,给出管道各截面湿蒸汽参数的计算方法。得到管道入口为干饱和蒸汽和湿蒸汽时管道各截面的蒸汽参数,并分析阻力对蒸汽参数的影响。结果表明:由于存在阻力使湿蒸汽的压力降低、温度降低、比容增大、流速增大、焓值降低;干度沿流动方向的变化规律主要与入口干度和入口压力有关。以1000MW核电汽轮机为例,在额定工况下,除主蒸汽干度将逐渐减小外,其它蒸汽管道内湿蒸汽在流动过程中干度都将逐渐增大。%Momentum equation was derived when wet steam flows through a straight pipeline with a constant cross section . Combined with energy equation and the continuity equation , a calculating method of steam parameters varying along the straight pipeline was given .Steam parameters was obtained when the inlet was dry saturated steam and wet saturated steam . The influence of the resistance to the steam parameters was analyzed .The results show that friction pressure loss lead to the decrease of temperature ,the increase of specific volume ,the increase of velocity and the decrease of enthalpy .The change rule of dryness varying along the pipeline mainly related with the inlet dryness and inlet pressure .Taking a 1 000 MW nuclear steam turbine as example,main steam dryness will gradually decrease,while the dryness in other steam pipeline will gradually increase under the rated operating conditions .

  6. Impact of milling, enzyme addition, and steam explosion on the solid waste biomethanation of an olive oil production plant.

    Science.gov (United States)

    Donoso-Bravo, Andres; Ortega-Martinez, E; Ruiz-Filippi, G

    2016-02-01

    Anaerobic digestion is a consolidated bioprocess which can be further enhanced by incorporating an upstream pretreatment unit. The olive oil production produces a large amount of solid waste which needs to be properly managed and disposed. Three different pretreatment techniques were evaluated in regard to their impact on the anaerobic biodegradability: manual milling of olive pomace (OP), enzyme maceration, direct enzyme addition, and thermal hydrolysis of two-phase olive mill waste. The Gompertz equation was used to obtain parameters for comparison purposes. A substrate/inoculum ratio 0.5 was found to be the best to be used in anaerobic batch test with olive pomace as substrate. Mechanical pretreatment of OP by milling increases the methane production rate while keeping the maximum methane yield. The enzymatic pretreatment showed different results depending on the chosen pretreatment strategies. After the enzymatic maceration pretreatment, a methane production of 274 ml CH4 g VS added (-1) was achieved, which represents an improvement of 32 and 71 % compared to the blank and control, respectively. The direct enzyme addition pretreatment showed no improvement in both the rate and the maximum methane production. Steam explosion showed no improvement on the anaerobic degradability of two-phase olive mill waste; however, thermal hydrolysis with no rapid depressurization enhanced notoriously both the maximum rate (50 %) and methane yield (70 %).

  7. IMPROVEMENT OF SYSTEMS OF TECHNICAL WATER SUPPLY WITH COOLING TOWERS FOR STEAM POWER PLANTS TECHNICAL AND ECONOMIC INDICATORS PERFECTION. Part 1

    Directory of Open Access Journals (Sweden)

    Yu. A. Zenovich-Leshkevich-Olpinskiy

    2016-01-01

    Full Text Available In order to reduce the temperature of cooling water and increase the efficiency of use of power resources the main directions of modernization of systems of technical water supply with cooling towers at steam power plants are presented. The problems of operation of irrigation systems and water distribution systems of cooling towers are reviewed. The design of heat and mass transfer devices, their shortcomings and the impact on the cooling ability of the cooling tower are also under analysis. The use of droplet heat and mass transfer device based on the lattice polypropylene virtually eliminates the shortcomings of the film and droplet-film heat and mass transfer devices of the cooling tower, increasing lifetime, and improving the reliability and efficiency of the operation of the main equipment of thermal power plants. The design of the water distribution devices of cooling towers is also considered. It is noted that the most effective are water-spattering low-pressure nozzles made of polypropylene that provides uniform dispersion of water and are of a high reliability and durability.

  8. Hard sludge removal in steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Santibanez, M.; Stoss, J.

    2013-07-01

    One of the majors problems during the life of Nuclear power plants is the efficiency lost in steam generator due to, among issues, the plugging and therefore useless, of tubes which presented possibility of cracking in the future. The hard sludge produced in the steam generators secondary side and deposited on the tube sheet or around the tubes as collar shape are one of the main agent causing this problem, so their elimination is considered a major topic in order to keep the steam generators in an optimum condition along the whole plant life. AREVA is aware of this global problem, therefore a process and tools have been continuously developed since 1995 in order to eliminate the hard deposits in a effective way, with no damage to steam generator's components and adaptable for the different steam generators models existing in the market.

  9. Isobaric gas and steam. Compressed air storage power plant with heat storage system; Isobares GuD. Druckluftspeicherkraftwerk mit Waermespeicher

    Energy Technology Data Exchange (ETDEWEB)

    Nielsen, Lasse; Leithner, Reinhard; Qi, Dawei [Technische Univ. Braunschweig (Germany). Inst. fuer Waerme- und Brennstofftechnik; Grote, Wolfgang; Kastsian, Darya; Moennigmann, Martin [Bochum Univ. (Germany). Lehrstuhl fuer Regelungstechnik und Systemtheorie

    2011-07-01

    The ISACOAST-CC (Isobaric Adiabatic Compressed Air Energy Storage - Combinde Cycle) is a innovative combination of combined cycle power plant, compressed air store and heat store. First calculations show that a storage efficiency of 80 % could be achieved.

  10. Research on Power Plant Steam Boiler Automatic Control System Based on Fuzzy Control%基于模糊控制的电厂蒸汽锅炉自动控制系统研究

    Institute of Scientific and Technical Information of China (English)

    周继春

    2013-01-01

      针对电厂发电过程中需对蒸汽锅炉进行自动控制的目的,提出了采用模糊控制原理实现蒸汽锅炉压力和温度的自动控制方案。通过深入研究火力发电厂中的蒸汽锅炉的工作循环过程,建立了蒸汽锅炉内部压力和温度的工作模型。文章详细设计了电厂蒸汽锅炉自动控制系统的总体方案,重点研究了模糊控制模块的设计原理和实现方法,给出了模糊控制中的隶属函数和各个主要变量的模糊化过程。最后通过仿真测试,分析了锅炉自动控制系统的工作性能。%Aiming at the automatic control aim in power plant generating electricity, this paper put forward a automatic control scheme steam boiler pressure and temperature, on fuzzy control principle. By further studying the steam boiler circulation process in thermal power plant, it built a steam boiler inner pressure and temperature working model. It design the power plant steam boiler automatic control system overall scheme in detail, focused on the design principle and implementation method, presented the membership function and main variables in the fuzzy process. At last, by simulation test, it analyzed the steam boiler control system working performance.

  11. Optimal integration of energy at the Combined Energy Plant in Norrkoeping -Integration of steam, hot water and district heat to biogas plants; Optimal integrering av energianvaendningen vid energikombinatet i Norrkoeping -Integrering av aanga, hetvatten och fjaerrvaerme till biogasanlaeggningar

    Energy Technology Data Exchange (ETDEWEB)

    Benjaminsson, Johan; Goldschmidt, Barbara; Uddgren, Roger

    2010-09-15

    The background of this report is to investigate and highlight the benefits of establishing a biogas plant nearby a combined energy plant where steam and district heat is available. By using heat from the combined energy plant, more biogas can be produced as vehicle fuel instead of being used as fuel to heat the digester, the biogas upgrading plant or the dryer. The project's objective is to analyze where it is interesting with integration of heat to the biogas plant and to compare alternative technologies and possible integration options. The stakeholders of the study are industries with access to organic matter for biogas production and heat producers who can deliver thermal energy into biogas plants. The project was implemented by collection of information from the Haendeloe combined energy plant outside Norrkoeping where there is a cogeneration plant, an ethanol plant and a biogas plant. Case studies for the study have been carried out with proposals regarding how heat flows from the power plant and ethanol plant can be further integrated with the biogas plant. As case studies, both the current design of the biogas plant, as well as a fictional case in which half of all distillery residues was digested, have been evaluated. The case studies show that in today's biogas plant it is not economical to replace the existing biogas upgrading unit with water absorption to chemical absorption. The upgrading cost with water absorption at today's smaller facility is 0.11 kr/kWh and in order to obtain the same total cost of chemical absorption a steam price of 0.15 kr/kWh is required. For large gas flows, chemical absorption is an advantage since the technology is more suitable for upscaling in comparison with water absorption that must be delivered in multiple lines. Nevertheless, a possibility to recover waste heat from chemical absorption is necessary if the technology shall be competitive. If waste heat from both water absorption and chemical absorption

  12. Computer code analysis of steam generator in thermal-hydraulic test facility simulating nuclear power plant; Ydinvoimalaitosta kuvaavan koelaitteiston hoeyrystimien analysointi tietokoneohjelmilla

    Energy Technology Data Exchange (ETDEWEB)

    Virtanen, E.

    1995-12-31

    In the study three loss-of-feedwater type experiments which were preformed with the PACTEL facility has been calculated with two computer codes. The purpose of the experiments was to gain information about the behaviour of horizontal steam generator in a situation where the water level on the secondary side of the steam generator is decreasing. At the same time data that can be used in the assessment of thermal-hydraulic computer codes was assembled. The purpose of the work was to study the capabilities of two computer codes, APROS version 2.11 and RELAP5/MOD3.1, to calculate the phenomena in horizontal steam generator. In order to make the comparison of the calculation results easier the same kind of model of the steam generator was made for both codes. Only the steam generator was modelled, the rest of the facility was given for the codes as a boundary condition. (23 refs.).

  13. Effect of chloride and sulfate ions in simulated AVT waters on electrochemical corrosion behavior and oxide film characteristics of LP steam turbine materials in power plants

    Energy Technology Data Exchange (ETDEWEB)

    Nakane, Takahiro [Shinshu Univ., Nagano City (Japan). Interdisciplinary Graduate School of Sience and Technology; Goto, Teruyuki [NSK Ltd., Tokyo (Japan); Niu, Li-Bin [Shinshu Univ., Nagano City (Japan). Dept. of Environmental Science and Technology; Takaku, Hiroshi [Shinshu Univ., Nagano City (Japan). Faculty of Engineering

    2010-07-15

    Electrochemical corrosion behavior and film characteristics were investigated in simulated all-volatile treatment (AVT) waters containing both sulfate (SO{sub 4}{sup 2-}) and chloride (Cl{sup -}) for 13Cr, 16Cr-4Ni, 3.5NiCrMoV and high-purity 9CrMoV steels of low-pressure (LP) steam turbines in power plants. Concerning the 13Cr, 16Cr-4Ni and high-purity 9CrMoV steels, the corrosion pit growth proceeded with an increasing content of SO{sub 4}{sup 2-} up to 50 mg x kg{sup -1} in the test water with 100 mg x kg{sup -1} Cl{sup -}, although a SO{sub 4}{sup 2-} concentration above 50 mg x kg{sup -1} in the test water suppressed the corrosion pit growth due to the combined effect of Cl{sup -} and SO{sub 4}{sup 2-}. No corrosion pits occurred for 3.5NiCrMoV steel, which showed predominantly general corrosion in the test waters with Cl{sup -} and SO{sub 4}{sup 2-}. It is concluded that both the heat-treatment-improved 16Cr-4Ni steel for blades and the newly developed high-purity 9CrMoV steel for rotors have a high resistance to pitting corrosion. (orig.)

  14. 汽轮机润滑油系统进水的治理%Management of water power plant steam turbine lubricating oil system

    Institute of Scientific and Technical Information of China (English)

    刘炜

    2014-01-01

    Combined with the moisture content of steam turbine lubricating oil exceed the standard phenomenon during the operation of the power plant, expounds the harm of water turbine lubricating oil system and cause water causes, introduces the reason of turbine shaft seal leakage, proposed to prevent water in lube oil system and reduce the lubricating oil system measures the moisture content, the favorable effect.%结合本电厂运行过程中出现的汽轮机润滑油水分含量超标现象,阐述了汽轮机润滑油系统进水的危害和引起进水原因,介绍了汽轮机轴封漏气的原因,提出了防止润滑油系统进水和降低润滑油系统中水分含量的具体措施,经过实施后效果良好。

  15. 火电厂600MW超临界机组汽轮机胀差控制分析%Steam Turbine Differential Expansion Controlling Analysis of 600 MW Supercritical Unit in Thermal Power Plant

    Institute of Scientific and Technical Information of China (English)

    杨晨; 朱懿

    2012-01-01

    N600-24.2/566/566 supercritical steam turbine which is made by Shanghai Steam Turbine Plant, for example, importance and variation of differential expansion controlling of steam turbine, mutual relations of the rotor and stator expansion, and the most effective technical measures of controlling differential expansion in the start-up process of Phase I 2 x 600 MW supercritical steam turbine of Huangjinbu Power Generation Co.,Ltd. of State Power Grid in Jiangxi were analyzed, and had some reference values for other turbines.%以上海汽轮机厂生产的N600.24.2/566/566型超临界汽轮机为例,分析了江西国电黄金埠发电有限公司1期2台600MW超临界汽轮机启动过程中,汽轮机胀差控制的重要性、变化规律、转子和静子膨胀的相互关系以及采取的最有效的控制胀差的技术措施,对于其它汽轮机具有一定的参考价值。

  16. Corrosion Evaluation and Corrosion Control of Steam Generators

    Energy Technology Data Exchange (ETDEWEB)

    Maeng, W. Y.; Kim, U. C.; Sung, K. W.; Na, J. W.; Lee, Y. H.; Lee, D. H.; Kim, K. M

    2008-06-15

    Corrosion damage significantly influences the integrity and efficiency of steam generator. Corrosion problems of steam generator are unsolved issues until now even though much effort is made around world. Especially the stress corrosion cracking of heat exchange materials is the first issue to be solved. The corrosion protection method of steam generator is important and urgent for the guarantee of nuclear plant's integrity. The objectives of this study are 1) to evaluate the corrosion properties of steam generator materials, 2) to optimize the water chemistry of steam generator and 3) to develop the corrosion protection method of primary and secondary sides of steam generator. The results will be reflected to the water chemistry guideline for improving the integrity and efficiency of steam generator in domestic power plants.

  17. System for Steam Leak Detection by using CCTV Camera

    Energy Technology Data Exchange (ETDEWEB)

    Choi, Young Chul; Lee, Min Soo; Choi, Hui Ju [Korea Atomic Energy Research Institute, Daejeon (Korea, Republic of); Son, Ki Sung; Jeon, Hyeong Seop [SAEAN.Co., Seoul (Korea, Republic of)

    2012-05-15

    There are many pipes in the secondary cooling systems of nuclear power plants and coal-fired power plants. In these pipes, high pressure fluids are moving with at high velocity, which can cause steam leakage due to pipe thinning. Steam leakage is one of the major issues for the structural fracture of pipes. Therefore, a method to inspect a large area of piping systems quickly and accurately is needed. Steam leakage is almost invisible, because the flow has very high velocity and pressure. Therefore, it is very difficult to detect a steam leakage. In this paper, we proposed the method for detecting steam leakage using image signal processing. Our basic idea comes from a heat shimmer, which shines with a soft light that looks as if it is being shaken slightly. To test the performance of this technique, experiments have been performed for a steam generator. Results show that the proposed technique is quite powerful for steam leak detection

  18. Best possible cycle chemistry control in steam turbine plants; Baesta moejliga oevervakning av vattenkemin i anlaeggningar med aangturbin

    Energy Technology Data Exchange (ETDEWEB)

    Hellman, Mats [Hellman Vatten AB, Stockholm (Sweden)

    2004-11-01

    A project has been conducted of a large number of power and pulp plants in Sweden. Production managers and those responsible for water quality control were visited and interviewed. In addition, a research of cycle chemistry literature has been conducted to determine what has been done in other countries. The review of this literature shows that the Electric Power Research Institute in the USA and ESKOM in South Africa are in the forefront regarding QA/QC and have come a long way in water control management. A key requirement for successful plant cycle chemistry is corporate management support. The project makes it clear that cycle chemistry control was best at plants where production management was aware of the importance of high water quality. There is a real need for feed water technique and water quality education at all company levels. The objective should be that 'everyone should know the importance of right water quality'. Personnel without an education in chemistry often regard cycle chemistry as somewhat complicated. Better understanding and better working cycle chemistry control can be obtained by making the control easier and clearer for persons without training in chemistry. Extensive on-line instrumentation with well-designed systems for presenting the data, by-far, gives the best cycle chemistry control. It is important to have a holistic view when water treatment systems and on-line instrumentation are planned. It is not the amount of instruments or the number of chemistry personnel that is important. The important thing is to ensure that all functions needed fit together in the best way possible. Today, when cycle chemistry monitoring is heavily dependent on on-line instrumentation, the reliability of the instruments is crucial. Therefore, it is important to have well-established routines for maintenance, calibration and service. In order to decrease forced outages of plants due to poor cycle chemistry, the focus of chemistry control should

  19. The practice of chemical treatment of the water/steam circuits in plants with forced flow once-through boilers. Praxis der chemischen Konditionierung von Wasser-Dampfkreislaeufen in Anlagen mit Zwangdurchlaufkesseln

    Energy Technology Data Exchange (ETDEWEB)

    Bursik, A. (Grosskraftwerk Mannheim AG (Germany)); Kittel, H. (VGB-Geschaeftsstelle, Essen (Germany))

    1992-02-01

    In 1990, a statistical survey was undertaken into the status of chemical treatment of water/steam circuits in plants with once-through forced-flow boilers. The results were reported at the VGB Conference on 'Chemistry in the Power Station 1990'. This paper imparts to the operators of plants with once-through forced-flow boilers additional information about the practice of chemical treatment. It contains guidelines concerning the chemicals used and also instructions about dosing points for individual materials and the type of dosing to be used in continuous operation. (orig.).

  20. Steam Digest 2001

    Energy Technology Data Exchange (ETDEWEB)

    2002-01-01

    Steam Digest 2001 chronicles BestPractices Program's contributions to the industrial trade press for 2001, and presents articles that cover technical, financial and managerial aspects of steam optimization.

  1. Use of self-organizing maps for classification of defects in the tubes from the steam generator of nuclear power plants; Classificacao de defeitos em tubos de gerador de vapor de plantas nucleares utilizando mapas auto-organizaveis

    Energy Technology Data Exchange (ETDEWEB)

    Mesquita, Roberto Navarro de

    2002-07-01

    This thesis obtains a new classification method for different steam generator tube defects in nuclear power plants using Eddy Current Test signals. The method uses self-organizing maps to compare different signal characteristics efficiency to identify and classify these defects. A multiple inference system is proposed which composes the different extracted characteristic trained maps classification to infer the final defect type. The feature extraction methods used are the Wavelet zero-crossings representation, the linear predictive coding (LPC), and other basic signal representations on time like module and phase. Many characteristic vectors are obtained with combinations of these extracted characteristics. These vectors are tested to classify the defects and the best ones are applied to the multiple inference system. A systematic study of pre-processing, calibration and analysis methods for the steam generator tube defect signals in nuclear power plants is done. The method efficiency is demonstrated and characteristic maps with the main prototypes are obtained for each steam generator tube defect type. (author)

  2. Steam Digest Volume IV

    Energy Technology Data Exchange (ETDEWEB)

    None

    2004-07-01

    This edition of the Steam Digest is a compendium of 2003 articles on the technical and financial benefits of steam efficiency, presented by the stakeholders of the U.S. Department of Energy's BestPractices Steam effort.

  3. The Invisibility of Steam

    Science.gov (United States)

    Greenslade, Thomas B., Jr.

    2014-01-01

    Almost everyone "knows" that steam is visible. After all, one can see the cloud of white issuing from the spout of a boiling tea kettle. In reality, steam is the gaseous phase of water and is invisible. What you see is light scattered from the tiny droplets of water that are the result of the condensation of the steam as its temperature…

  4. Wisconsinan and early Holocene glacial dynamics of Cumberland Peninsula, Baffin Island, Arctic Canada

    Science.gov (United States)

    Margreth, Annina; Gosse, John C.; Dyke, Arthur S.

    2017-07-01

    Three glacier systems-an ice sheet with a large marine-based ice stream, an ice cap, and an alpine glacier complex-coalesced on Cumberland Peninsula during the Late Wisconsinan. We combine high-resolution mapping of glacial deposits with new cosmogenic nuclide and radiocarbon age determinations to constrain the history and dynamics of each system. During the Middle Wisconsinan (Oxygen Isotope Stage 3, OIS-3) the Cumberland Sound Ice Stream of the Laurentide Ice Sheet retreated well back into Cumberland Sound and the alpine ice retreated at least to fiord-head positions, a more significant recession than previously documented. The advance to maximal OIS-2 ice positions beyond the mouth of Cumberland Sound and beyond most stretches of coastline remains undated. Partial preservation of an over-ridden OIS-3 glaciomarine delta in a fiord-side position suggests that even fiord ice was weakly erosive in places. Moraines formed during deglaciation represent stillstands and re-advances during three major cold events: H-1 (14.6 ka), Younger Dryas (12.9-11.7 ka), and Cockburn (9.5 ka). Distinctly different responses of the three glacial systems are evident, with the alpine system responding most sensitively to Bølling-Allerød warming whereas the larger systems retreated mainly during Pre-Boreal warming. While the larger ice masses were mainly influenced by internal dynamics, the smaller alpine glacier system responded sensitively to local climate effects. Asymmetrical recession of the alpine glacier complex indicates topoclimatic control on deglaciation and perhaps migration of the accumulation area toward moisture source.

  5. Development of technical solutions on a coal-fired boiler for a power plant unit of 800 MW with steam parameters of 35 MPa and 700/720°C

    Science.gov (United States)

    Shvarts, A. L.; Verbovetsky, E. Kh.; Somova, E. V.; Smolin, A. V.

    2015-12-01

    Development of a coal-fired boiler for a power plant unit of 800 MW with advanced ultra-supercritical steam parameters of 35 MPa and 700/720°C is presented. The main technical solutions providing the reliability, profitability, and low emissions of harmful substances in the atmosphere are given. The fuel is the black coal of (Taldinskoye field, Kuznetsk basin). The gross efficiency of the boiler is 94%. The U-shaped configuration of a boiler is chosen, which allows the reduction of the capital expenditure for steam turbine piping made of expensive nickel alloys. The horizontal connection flue of the boiler, where the primary and reheat steam screens are located, is equipped with two cold funnels. The upper section of the convection shaft is separated with a vertical screen wall into two parallel "split tail" flues, which allows one to control the reheat steam temperature by redistributing the flue gas between the gas flues. The URS screens are two-stage with a lifting motion of the medium and a partial bypassing of the first stage. The lower radiant section is two-stage. To reduce the temperature of screen walls at the fire chamber outlet, the lowering motion of the working medium and combustion gases is used. The hydrodynamics of the screens with the lowering motion of the medium for preventing the aperiodic instability in the start regimes is analyzed. Besides the stepwise combustion of coal dust providing the improved environmental parameters, the boiler plant is equipped with a selective catalytic reduction (SCR) system, an ash collector (an electric filter combined with a filter bag), and a desulphurization device.

  6. Some perspective decisions for the regeneration system equipment of the thermal and nuclear power plants decreasing the probability of water ingress into the turbine and rotor acceleration by return steam flow

    Science.gov (United States)

    Trifonov, N. N.; Svyatkin, F. A.; Sintsova, T. G.; Ukhanova, M. G.; Yesin, S. B.; Nikolayenkova, E. K.; Yurchenko, A. Yu.; Grigorieva, E. B.

    2016-03-01

    The regeneration system heaters are one of the sources of possible ingress of the water into the turbine. The water penetrates into the turbine either at the heaters overflow or with the return flow of steam generated when the water being in the heater boils up in the dynamic operation modes or at deenergization of the power-generating unit. The return flow of steam and water is dangerous to the turbine blades and can result in the rotor acceleration. The known protective devices used to prevent the overflow of the low-pressure and high-pressure heaters (LPH and HPH), of the horizontal and vertical heaters of heating-system water (HWH and VWH), as well as of the deaerators and low-pressure mixing heaters (LPMH) were considered. The main protective methods of the steam and water return flows supplied by the heaters in dynamic operation modes or at deenergization of the power-generating unit are described. Previous operating experience shows that the available protections do not fully prevent water ingress into the turbine and the rotor acceleration and, therefore, the development of measures to decrease the possibility of ingress of the water into the turbine is an actual problem. The measures allowing eliminating or reducing the water mass in the heaters are expounded; some of them were designed by the specialists of OAO Polzunov Scientific and Development Association on Research and Design of Power Equipment (NPO CKTI) and are efficiently introduced at heat power plants and nuclear power plants. The suggested technical solutions allow reducing the possibility of the water ingress into the turbine and rotor acceleration by return steam flow in the dynamic operation modes or in the case of power generating unit deenergization. Some of these solutions have been tested in experimental-industrial exploitation and can be used in industry.

  7. Structure of the western Cumberland Basin : implications for coalbed-methane exploration

    Energy Technology Data Exchange (ETDEWEB)

    Waldron, J.W.F. [Alberta Univ., Edmonton, AB (Canada). Dept. of Earth and Atmospheric Sciences; Rygel, M.C. [Nebraska-Lincoln Univ., Lincoln, NE (United States). Dept. of Geosciences

    2006-07-01

    The Athol Syncline is a prominent structure in the western Cumberland Basin of Nova Scotia. The basin contains a Carboniferous succession and is currently a target for exploration for coalbed methane. Subsidence and tectonism in the Cumberland Basin were partly controlled by differential flow of Windsor Group evaporites. The Joggins Formation in the Athol Syncline is famous for preserved upright fossil trees. New seismic profiles reveal that the Athol Syncline has potential traps for conventional hydrocarbons where thick fluvial sand units rest against salt walls at the margins of minibasins. The Cumberland Group is thin and lacks significant coals. A basinwide comparison showed that salt withdrawal at depth was responsible for much of the subsidence responsible for the preservation of the coal-bearing Joggins Formation. Contouring of reflections in the seismic profiles provided better definition of the subsurface geometries and potential extent of coal-bearing units in the Athol syncline. The subsurface geometries revealed some new exploration targets for this and similar depocentres in the Maritimes Basin. Coal distribution was found to be influenced by both tectonism and differential withdrawal of evaporites.

  8. Health Status and Cancer Screening in Hispanic Women: A Sample from Cumberland County, North Carolina

    Directory of Open Access Journals (Sweden)

    Heather Griffiths

    2011-05-01

    Full Text Available This exploratory study examines self-reported breast and cervical cancer screening history among women aged 18 years and above in Cumberland County, NC. Cumberland County is a multi-ethnic, semi-urban, racially diverse community with a large Hispanic population. Cross-sectional, mixed methodology data collection took place in local Tiendas. The sample consists of women belonging to a variety of ethnic groups generally classified as “Hispanic.” The questionnaire and interview guide used in the study developed from the Center for Disease Control’s National Health Interview Survey, and measured breast examination, mammogram, Pap Smear, family cancer, and health insurance history, as well as self reported health status, socio-demographic, and cultural features of the respondents. We found that despite demographics from the 2010 Census showing a high incidence of breast and cervical cancers in the North Carolina Hispanic population, fewer Hispanic women in Cumberland County screened themselves for the presence of this cancer as compared to women at the national level. Education positively impacted both self rated health status as well as cancer screening behavior. Interview data suggested the lack of screening behavior in this population was due to a perceived lack of cultural sensitivity and a dearth of translators.

  9. Experiences with industrial solar process steam generation in Jordan

    Science.gov (United States)

    Krüger, Dirk; Berger, Michael; Mokhtar, Marwan; Willwerth, Lisa; Zahler, Christian; Al-Najami, Mahmoud; Hennecke, Klaus

    2017-06-01

    At the Jordanian pharmaceuticals manufacturing company RAM Pharma a solar process heat supply has been constructed by Industrial Solar GmbH in March 2015 and operated since then (Figure 1). The collector field consists of 394 m² of linear Fresnel collectors supplying saturated steam to the steam network at RAM Pharma at about 6 bar gauge. In the frame of the SolSteam project funded by the German Federal Ministry for Economic Affairs and Energy (BMWi) the installation has been modified introducing an alternative way to separate water and steam by a cyclone. This paper describes the results of experiments with the cyclone and compares the operation with a steam drum. The steam production of the solar plant as well as the fuel demand of the steam boiler are continuously monitored and results are presented in this paper.

  10. RADIOACTIVE DEMONSTRATION OF FINAL MINERALIZED WASTE FORMS FOR HANFORD WASTE TREATMENT PLANT SECONDARY WASTE BY FLUIDIZED BED STEAM REFORMING USING THE BENCH SCALE REFORMER PLATFORM

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C.; Burket, P.; Cozzi, A.; Daniel, W.; Jantzen, C.; Missimer, D.

    2012-02-02

    The U.S. Department of Energy's Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford's tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in the time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. In addition, the WTP LAW vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as {sup 137}Cs, {sup 129}I, {sup 99}Tc, Cl, F, and SO{sub 4} that volatilize at the vitrification temperature of 1150 C in the absence of a continuous cold cap (that could minimize volatilization). The current waste disposal path for the WTP-SW is to process it through the Effluent Treatment Facility (ETF). Fluidized Bed Steam Reforming (FBSR) is being considered for immobilization of the ETF concentrate that would be generated by processing the WTP-SW. The focus of this current report is the WTP-SW. FBSR offers a moderate temperature (700-750 C) continuous method by which WTP-SW wastes can be processed irrespective of whether they contain organics, nitrates, sulfates/sulfides, chlorides, fluorides, volatile radionuclides or other aqueous components. The FBSR technology can process these wastes into a crystalline

  11. Experimental investigation of the steam wetness in a 1000 MW steam turbine

    Science.gov (United States)

    Kolovratník, Michal; Bartoš, Ondřej

    2016-03-01

    The aim of this paper is to introduce the experimental data of the wetness distribution obtained in the year 2015 in front of and behind the last stage of the 1000MW steam turbine in the power plant Temelín. Two different optical probes developed at Czech Technical University were used. For the first time in the Czech Republic pneumatic and optical measurement of the wet steam flow field in front of the last stage of a nuclear power-station steam turbine was provided. This unique measurement opportunity provided lots of new information for the manufacturer and operator of the steam turbine and valuable experimental data for the phase transition modelling in the wet steam flow. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o.

  12. Experimental investigation of the steam wetness in a 1000 MW steam turbine

    Directory of Open Access Journals (Sweden)

    Kolovratník Michal

    2016-01-01

    Full Text Available The aim of this paper is to introduce the experimental data of the wetness distribution obtained in the year 2015 in front of and behind the last stage of the 1000MW steam turbine in the power plant Temelín. Two different optical probes developed at Czech Technical University were used. For the first time in the Czech Republic pneumatic and optical measurement of the wet steam flow field in front of the last stage of a nuclear power-station steam turbine was provided. This unique measurement opportunity provided lots of new information for the manufacturer and operator of the steam turbine and valuable experimental data for the phase transition modelling in the wet steam flow. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o.

  13. Simulation of Dynamic Characteristics of Steam Accumulators in the Badaling Solar Power Tower Plant%八达岭塔式太阳能热发电蒸汽蓄热器动态特性仿真

    Institute of Scientific and Technical Information of China (English)

    徐二树; 高维; 徐蕙; 杨正

    2012-01-01

    A whole working condition mathematical model for the steam accumulator in Badaling solar power tower plant was developed.According to the structure and working mechanism of the steam accumulator,the dynamic energy and mass conservation equations in both the vapor region and the liquid region were established.Dynamic mass and energy transport between the vapor region and the liquid region was considered by introducing the vaporization and condensation through the vapor-liquid interface.Based on STAR-90 simulation platform,the charging and discharging processes of the steam accumulator were simulated,and the step disturbance of steam flow during the charging and discharging processes was numerically investigated.The results show that the characteristics of pressure variation in the steam accumulator in the charging process are different from that in the discharging process.In the discharging process,the steam temperature can be evidently influenced when increasing the steam flow rate,easily causing a low superheat steam at the turbine inlet.The findings in this paper provide valuable insights into the design and control strategy of solar thermal power plants with thermal storage systems.%以八达岭塔式太阳能热发电实验电站蒸汽蓄热器为研究对象,根据蒸汽蓄热器的结构和工作机制,建立蒸汽蓄热器的全工况动态仿真数学模型。该模型以汽液两相分界面为界,分别建立汽相区和液相区动态能量和质量守恒方程式,引入动态汽化量和蒸汽凝结量,实现汽、液相区之间能质传递。在此基础上,利用STAR-90仿真平台模拟八达岭塔式太阳能热发电站蓄热器的充热和放热过程,进行充、放热蒸汽流量阶跃扰动实验。仿真实验表明:蒸汽蓄热器在充热过程和放热过程具有不同的压力变化特性;放热过程中,蒸汽流量增加对蒸汽温度影响幅度较大,容易导致汽轮机入口蒸汽过热度偏低。该结论对具有蓄热系

  14. 浅析甲醇联合装置蒸汽转化炉钢结构超温原因%Analysis of Steel Structure Overheat for the Steam Reformer in a Methanol Plant Commissioning

    Institute of Scientific and Technical Information of China (English)

    黄天进; 王强

    2014-01-01

    针对某化工项目甲醇联合装置蒸汽转化炉投料试车时,发现的转化炉炉顶和炉底钢结构超温现象,笔者采用ANSYS有限元分析软件对转化炉炉顶和炉底衬里结构进行数值传热计算,计算结果表明:转化炉炉顶钢板温度受燃烧器耐火砖直接热传导和周围环境温度的影响显著;转化炉炉底钢板温度的数值计算值与实测值具有较高一致性,证实了专利商工艺包中炉底结构不合理是引起炉底板超温的直接原因。%The steel structure located at the steam reformer roof and floor appears overheat in the methanol plant commissioning stage. The author completes the heat-transfer calculations of the lining instal ed at steam reformer roof and floor with the help of the ANSYS finite element analysis software. The numerical calculation results indicate that the direct heat impact on roof steel structure from burner tile is obvious and the effect of ambient temperature is also non-ignorable. It is also shown that the calculated temperature values of steam reform floor steel structure can consist with the recorded data as wel as confirm the unreasonable floor lining structure defined in the steam reformer package which gives rise to the floor steel structure over heat final y.

  15. Eddy-current tests on operational evaluation of steam generator tubes in nuclear power plants; Ensaios de Eddy-current na avaliacao do estado operacional de tubos de geradores de vapor de centrais nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Lopez, Luiz Antonio Negro Martin [Faculdade de Engenharia Industrial (FEI), Sao Paulo, SP (Brazil). Dept. de Energetica]. E-mail: luizlope@cci.fei.br; Ting, Daniel Kao Sun [Instituto de Pesquisas Energeticas e Nucleares (IPEN-CNEN/SP), Sao Paulo, SP (Brazil). Dept. Engenharia de Reatores]. E-mail: dksting@net.ipen.br

    2000-07-01

    This paper presents a worldwide research on the technical and economical impacts due to failure in tube bundles of nuclear power plant steam generators. An Eddy current non destructive test using Foucault currents for the inspection and failure detection on the tubes, and also the main type of defects. The paper also presents the signals generated by a Zetec MIZ-40 test equipment. This paper also presents a brief description of an automatic system for data analysis which is under development by using a fuzzy logic and artificial intelligence.

  16. Pretreatment of Corn Stalk by Steam Explosion

    Institute of Scientific and Technical Information of China (English)

    邵自强; 田永生; 谭惠民

    2003-01-01

    A steam explosion pretreatment, which is one of the best ways of pretreating plant stalk, is applied at various severities to corn stalk. It could effectively modify the super-molecular structure of corn stalk and defibrating corn stalk into individual components. The relationship between yield of reducing sugar and the operating conditions, including temperature, pressure of steam explosion pretreatment and acidity, is also established. Experimental results prove that the steam explosion substantially increases the yield of reducing sugar, and the optimal condition for steam explosion is as follows: the pressure is 2.0 MPa, the pressure-retaining time 300 s, the initial acid concentration 1% and the acid treatment time 24 h.

  17. Failure analysis of retired steam generator tubings

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Hong Pyo; Kim, J. S.; Hwang, S. S. and others

    2005-04-15

    Degradation of steam generator leads to forced outage and extension of outage, which causes increase in repair cost, cost of purchasing replacement power and radiation exposure of workers. Steam generator tube rupture incident occurred in Uljin 4 in 2002, which made public sensitive to nuclear power plant. To keep nuclear energy as a main energy source, integrity of steam generator should be demonstrated. Quantitative relationship between ECT(eddy current test) signal and crack size is needed in assesment of integrity of steam generator in pressurized water reactor. However, it is not fully established for application in industry. Retired steam generator of Kori 1 has many kinds of crack such as circumferential and axial primary water stress corrosion crack and outer diameter stress corrosion crack(ODSCC). So, it can be used in qualifying and improving ECT technology and in condition monitoring assesment for crack detected in ISI(in service inspection). In addition, examination of pulled tube of Kori 1 retired steam generator will give information about effectiveness of non welded sleeving technology which was employed to repair defect tubes and remedial action which was applied to mitigate ODSCC. In this project, hardware such as semi hot lab. for pulled tube examination and modification transportation cask for pulled tube and software such as procedure of transportation of radioactive steam generator tube and non-destructive and destructive examination of pulled tube were established. Non-destructive and destructive examination of pulled tubes from Kori 1 retired steam generator were performed in semi hot lab. Remedial actions applied to Kori 1 retired steam generator, PWSCC trend and bulk water chemistry and crevice chemistry in Kori 1 were evaluated. Electrochemical decontamination technology for pulled tube was developed to reduce radiation exposure and enhance effectiveness of pulled tube examination. Multiparameter algorithm developed at ANL, USA was

  18. Niederaussem电站1000MW超临界汽轮机%1000 MW Supercritical Steam Turbine for the Niederaussem Plant

    Institute of Scientific and Technical Information of China (English)

    Wilfried Ulm; Dale Ernette; John Kern; Ralf M. Bell

    2003-01-01

    本文对Niederaussem K电站汽轮机的初始运行情况展开讨论,并对已使用的最新技术进行了详细的论述.%This paper will discuss the details of this latest technology as well as the initial operating experience of the Niederaussem K steam turbine.

  19. Experimental investigation of the steam wetness in a 1000 MW steam turbine

    OpenAIRE

    Kolovratník Michal; Bartoš Ondřej

    2016-01-01

    The aim of this paper is to introduce the experimental data of the wetness distribution obtained in the year 2015 in front of and behind the last stage of the 1000MW steam turbine in the power plant Temelín. Two different optical probes developed at Czech Technical University were used. For the first time in the Czech Republic pneumatic and optical measurement of the wet steam flow field in front of the last stage of a nuclear power-station steam turbine was provided. This unique measurement ...

  20. An Isothermal Steam Expander for an Industrial Steam Supplying System

    OpenAIRE

    Chen-Kuang Lin; Guang-Jer Lai; Yoshiyuki Kobayashi; Masahiro Matsuo; Min-Chie Chiu

    2015-01-01

    Steam is an essential medium used in the industrial process. To ensure steam quality, small and middle scale boilers are often adopted. However, because a higher steam pressure (compared to the necessary steam pressure) is generated, the boiler’s steam pressure will be reduced via a pressure regulator before the steam is directed through the process. Unfortunately, pressure is somewhat wasted during the reducing process. Therefore, in order to promote energy efficiency, a pressure regulator i...

  1. Modelling of a Coil Steam Generator for CSP applications

    DEFF Research Database (Denmark)

    Pelagotti, Leonardo; Sørensen, Kim; Condra, Thomas Joseph;

    2014-01-01

    The project investigates a new design for a CSP plant steam generation system, the Coil Steam Generator (CSG). This system allows faster start-ups and therefore higher daily energy production from the Sun. An analytical thermodynamic simulation model of the evaporator and a mechanical analysis...

  2. Solar process steam for a pharmaceutical company in Jordan

    Science.gov (United States)

    Berger, M.; Mokhtar, M.; Zahler, C.; Al-Najami, M. M. R.; Krüger, D.; Hennecke, K.

    2016-05-01

    This paper presents details of the recent installation of a linear Fresnel collector to provide saturated steam for process heat usage through Direct Steam Generation (DSG) for industrial use in the Jordanian pharmaceuticals manufacturing company RAM Pharma, where first solar steam has been provided in March 2015. This commercial DSG project also represents the first solar DSG plant in MENA. During sunshine, the system achieves a solar fraction of 100 %, and the conventional steam boiler is not needed. In the evening the fossil fired backup takes over automatically and replaces the solar collector in operation. Operational experience, details of the control strategy, and measurement data are presented in the paper.

  3. Status of steam generator tubing integrity at Jaslovske Bohunice NPP

    Energy Technology Data Exchange (ETDEWEB)

    Cepcek, S. [Nuclear Regulatory Authority of the Slovak Republic, Trnava (Slovakia)

    1997-02-01

    Steam generator represents one of the most important component of nuclear power plants. Especially, loss of tubing integrity of steam generators can lead to the primary coolant leak to secondary circuit and in worse cases to the unit shut down or to the PTS events occurrence. Therefore, to ensure the steam generator tubing integrity and the current knowledge about tube degradation propagation and development is of the highest importance. In this paper the present status of steam generator tubing integrity in operated NPP in Slovak Republic is presented.

  4. Safety Picks up "STEAM"

    Science.gov (United States)

    Roy, Ken

    2016-01-01

    This column shares safety information for the classroom. STEAM subjects--science, technology, engineering, art, and mathematics--are essential for fostering students' 21st-century skills. STEAM promotes critical-thinking skills, including analysis, assessment, categorization, classification, interpretation, justification, and prediction, and are…

  5. Integrated vacuum absorption steam cycle gas separation

    Science.gov (United States)

    Chen, Shiaguo; Lu, Yonggi; Rostam-Abadi, Massoud

    2011-11-22

    Methods and systems for separating a targeted gas from a gas stream emitted from a power plant. The gas stream is brought into contact with an absorption solution to preferentially absorb the targeted gas to be separated from the gas stream so that an absorbed gas is present within the absorption solution. This provides a gas-rich solution, which is introduced into a stripper. Low pressure exhaust steam from a low pressure steam turbine of the power plant is injected into the stripper with the gas-rich solution. The absorbed gas from the gas-rich solution is stripped in the stripper using the injected low pressure steam to provide a gas stream containing the targeted gas. The stripper is at or near vacuum. Water vapor in a gas stream from the stripper is condensed in a condenser operating at a pressure lower than the stripper to concentrate the targeted gas. Condensed water is separated from the concentrated targeted gas.

  6. Heat Recovery Steam Generator by Using Cogeneration

    Directory of Open Access Journals (Sweden)

    P.Vivek, P. Vijaya kumar

    2014-01-01

    Full Text Available A heat recovery steam generator or HRSG is an energy recovery heat exchanger that recovers heat from a hot gas stream. It produces steam that can be used in a process (cogeneration or used to drive a steam turbine (combined cycle. It has been working with open and closed cycle. Both of cycles are used to increase the performance and also power on the cogeneration plant. If we are using closed cycle technology, we can recycle the waste heat from the turbine. in cogeneration plant, mostly they are using open cycle technology. additional, by using closed cycle technology, we can use the waste heat that converts into useful amount of work. In this paper, the exhaust gas will be sent by using proper outlet from cogen unit, we are using only waste heat that produce from turbine.

  7. Reciprocating wear in a steam environment

    Energy Technology Data Exchange (ETDEWEB)

    Brown, L.J.; Gee, M.G. [National Physical Laboratory, Teddington, Middlesex (United Kingdom)

    2010-07-01

    Tests to simulate the wear between sliding components in steam power plant have been performed using a low frequency wear apparatus at elevated temperatures under static load, at ambient pressure, in a steam environment. The apparatus was modified to accept a novel method of steam delivery. The materials tested were pre-exposed in a flowing steam furnace at temperature for either 500 or 3000 hours to provide some simulation of long term ageing. The duration of each wear test was 50 hours and tests were also performed on as-received material for comparison purposes. Data has been compared with results of tests performed on non-oxidised material for longer durations and also on tests without steam to examine the effect of different environments. Data collected from each test consists of mass change, stub height measurement and friction coefficient as well as visual inspection of the wear track. Within this paper, it is reported that both pre-ageing and the addition of steam during testing clearly influence the friction between material surfaces. (orig.)

  8. 低压余热回收蒸汽发电技术在球团厂的应用%Application of the Technology of Power Generation with Low-pressure Steam from Recovered Waste Heat in a Pelletizing Plant

    Institute of Scientific and Technical Information of China (English)

    王荣雷

    2014-01-01

    The application of the technology of power generation with low-pressure steam from recovered waste heat in a pelletizing plant and the good economic results are discussed through introduction of a waste heat power generation project at a pelletizing plant of some steel company. The process flow, principle, main equipment and technical parameters and e-conomic result of the project are described in detail.%通过某公司球团厂余热发电项目的介绍,探讨低压余热回收蒸汽发电技术在球团厂的应用及其产生的良好经济效益。详细介绍了工艺流程、原理及主要设备技术参数、经济效益等。

  9. Thermoelastic steam turbine rotor control based on neural network

    Science.gov (United States)

    Rzadkowski, Romuald; Dominiczak, Krzysztof; Radulski, Wojciech; Szczepanik, R.

    2015-12-01

    Considered here are Nonlinear Auto-Regressive neural networks with eXogenous inputs (NARX) as a mathematical model of a steam turbine rotor for controlling steam turbine stress on-line. In order to obtain neural networks that locate critical stress and temperature points in the steam turbine during transient states, an FE rotor model was built. This model was used to train the neural networks on the basis of steam turbine transient operating data. The training included nonlinearity related to steam turbine expansion, heat exchange and rotor material properties during transients. Simultaneous neural networks are algorithms which can be implemented on PLC controllers. This allows for the application neural networks to control steam turbine stress in industrial power plants.

  10. An Isothermal Steam Expander for an Industrial Steam Supplying System

    Directory of Open Access Journals (Sweden)

    Chen-Kuang Lin

    2015-01-01

    Full Text Available Steam is an essential medium used in the industrial process. To ensure steam quality, small and middle scale boilers are often adopted. However, because a higher steam pressure (compared to the necessary steam pressure is generated, the boiler’s steam pressure will be reduced via a pressure regulator before the steam is directed through the process. Unfortunately, pressure is somewhat wasted during the reducing process. Therefore, in order to promote energy efficiency, a pressure regulator is replaced by a steam expander. With this steam expander, the pressure will be transformed into mechanical energy and extracted during the expansion process. A new type of isothermal steam expander for an industrial steam supplying system will be presented in the paper. The isothermal steam expander will improve the energy efficiency of a traditional steam expander by replacing the isentropic process with an isothermal expansion process. With this, steam condensation will decrease, energy will increase, and steam quality will be improved. Moreover, the mathematical model of the isothermal steam expander will be established by using the Schmidt theory, the same principle used to analyze Stirling engines. Consequently, by verifying the correctness of the theoretical model for the isothermal steam expander using experimental data, a prototype of 100 c.c. isothermal steam expander is constructed.

  11. Steam treatment of zebra mussels

    Energy Technology Data Exchange (ETDEWEB)

    Tsou, J. [Electric Power Research Institute, Palo Alto, CA (United States); Rybarik, D.L.; Thiel, J. [Dairyland Power Cooperative, La Crosse, WI (United States); Mussalli, Y.G.; Collins, F. [Stone & Webster Environmental Technology & Services, Boston, MA (United States)

    1996-08-01

    Steam injection into intake bays is a nonchemical method to control zebra mussels. This technique was demonstrated at Dairyland Power Cooperative`s J.P. Madgett Station located in Alma, Wisconsin. The project was funded by the EPRI Zebra Mussel Consortium which includes: Dairyland Power Cooperative, Central Illinois Public Service, Duke Power, Illinois Power Company, PSI Energy, Public Service Electric & Gas, and Tennessee Valley Authority. This technique can be used by other power plants around the nation. The steam treatments were performed at the J.P. Madgen intake in Alma, Wisconsin, on September 14 and 18, 1994. The J.P. Madgen Station has two water intake bays with capacities of approximately 295,000 gallons and 265,000 gallons each. Each intake can be isolated, permitting either full or reduced generation depending on river temperature conditions. In addition to the intake bays, the outside fire protection loop and hydrants were also treated with the hot water from one of the bays. This paper presents the process design, piping and steam educator configurations, portable industrial boiler sizing and description, and the thermocouples to monitor the water temperature in the intake bay. The biological mortality and control test protocol and treatment results are also presented. Treatment effectiveness was 100%, however equipment installation and operation was more problematic than anticipated. 3 refs., 5 figs., 2 tabs.

  12. Performance Monitoring and Fault Diagnosis of Wet-steam Turbines for Nuclear Power Plants%核电站汽轮机运行性能监测与诊断

    Institute of Scientific and Technical Information of China (English)

    邓德兵; 赵清森; 陈伟; 刘刚

    2011-01-01

    就核电汽轮机与火电汽轮机的差异以及由此差异引起的湿蒸汽汽轮机通流性能表征与热平衡计算的难点进行了论述,提出了利用特征通流面积CFA来表征核电汽轮机的通流性能和采用小误差热平衡法来计算核电汽轮机的热平衡图,应用小误差热平衡法和特征通流面积成功开发了核电站热力性能在线监测与分析系统和核电站汽轮机全面热力试验计算软件,并将这两项技术应用在大亚湾核电机组热力性能在线监测与分析系统和岭澳二期核电机组全面热力试验中.结果表明:实际运行监测中特征通流面积监测值的测量精度可控制在1%以内.%An introduction is being presented to differences between nuclear and thermal power steam turbines,together with a description to the consequent difficulties in flow performance characterization and heat balance calculation.The concept of characteristic flow area(CFA) and the method of slight error heat balance(SEHB) are proposed to respectively characterize the flow performance and carry out relevant thermal calculations for nuclear power steam turbines,with which a series of software are developed for on-line performance monitoring/analysis and thermal calculation purposes.The two developed technologies have been applied to on-line performance monitoring/analysis of steam turbine in Daya Bay Nuclear Power Plant and to thermal performance test of steam turbine in Lingao Phase II Nuclear Power Plant.Actual operation results show that the measurement of CFA can be controlled within an accuracy of 1%.

  13. State-of-the-art turbine technology enabling extremely high steam temperatures in unit R of the Boxberg power plant. Significantly contributing to a reduction of CO{sub 2} emissions; Modernste Turbinentechnologie mit hoechsten Dampftemperaturen fuer das Kraftwerk Boxberg, Block R. Ein signifikanter Beitrag zur Reduktion der CO{sub 2}-Emissionen

    Energy Technology Data Exchange (ETDEWEB)

    Tremmel, A.; Brandt, C. [ALSTOM Power Generation AG, Mannheim (Germany); Mandel, H. [Vattenfall Europe Generation AG und Co. KG, Cottbus (Germany); Klauke, U. [Vattenfall Europe Powerconsult GmbH, Vetschau (Germany)

    2006-07-01

    This paper will describe the steam turbo-generator set designed for the Boxberg Power Plant, Unit R. Consistent measures of improvement have been taken, based on field-proven technology. For instance, the use of state-of-the-art materials, developed by European research groups, allows the plant to be run with extremely high steam parameters. In addition, the flow configuration in the turbine is optimised in all areas. This includes the use of advanced aerodynamic profiles for the blading and an optimised design for the low-pressure last stages, combined with a downstream diffuser. (orig.)

  14. Thermal hydraulic studies in steam generator test facility

    Energy Technology Data Exchange (ETDEWEB)

    Vinod, V.; Suresh Kumar, V.A.; Noushad, I.B.; Ellappan, T.R.; Rajan, K.K.; Rajan, M.; Vaidyanathan, G. [Engineering Development Group Indira Gandhi Centre for Atomic Research, Kalpakkam-603102 (India)

    2005-07-01

    Full text of publication follows: A 500 MWe fast breeder reactor is being constructed at Kalpakkam, India. This is a sodium cooled reactor with two primary and two secondary sodium loops with total 8 steam generators. The typical advantage of fast breeder plants is the high operating temperature of steam cycles and the high plant efficiency. To produce this high pressure and high temperature steam, once through straight tube vertical sodium heated steam generators are used. The steam is generated from the heat produced in the reactor core and being transported through primary and secondary sodium circuits. The steam generator is a 25 m high middle supported steam generator with expansion bend and 23 m heat transfer length. Steam Generator Test Facility (SGTF) constructed at Indira Gandhi Centre for Atomic Research (IGCAR), Kalpakkam aims at performing various tests on a 5.5 MWt steam generator. This vertically simulated test article is similar in all respects to the proposed 157 MWt steam generator module for the Prototype Fast Breeder Reactor (PFBR), with reduced number of tubes. Heat transfer performance tests are done with this 19 tube steam generator at various load conditions. Sodium circuit for the SGTF is equipped with oil fired heater as heat source and centrifugal sodium pump, to pump sodium at 105 m{sup 3}/hr flow rate. Other typical components like sodium to air heat exchanger, sodium purification system and hydrogen leak detection system is also present in the sodium circuit. High pressure steam produced in the steam generator is dumped in a condenser and recycled. Important tests planned in SGTF are the heat transfer performance test, stability test, endurance test and performance test of steam generator under various transients. The controlled operation of steam generator will be studied with possible control schemes. A steady state simulation of the steam generator is done with a mathematical model. This paper gives the details of heat transfer

  15. USGS Nonindigenous Aquatic Species database with a focus on the introduced fishes of the lower Tennessee and Cumberland drainages

    Science.gov (United States)

    Fuller, Pam L.; Cannister, Matthew; Johansen, Rebecca; Estes, L. Dwayne; Hamilton, Steven W.; Barrass, Andrew N.

    2013-01-01

    The Nonindigenous Aquatic Species (NAS) database (http://nas.er.usgs.gov) functions as a national repository and clearinghouse for occurrence data for introduced species within the United States. Included is locality information on over 1,100 species of vertebrates, invertebrates, and vascular plants introduced as early as 1850. Taxa include foreign (exotic) species and species native to North America that have been transported outside of their natural range. Locality data are obtained from published and unpublished literature, state, federal and local monitoring programs, museum accessions, on-line databases, websites, professional communications and on-line reporting forms. The NAS web site provides immediate access to new occurrence records through a real-time interface with the NAS database. Visitors to the web site are presented with a set of pre-defined queries that generate lists of species according to state or hydrologic basin of interest. Fact sheets, distribution maps, and information on new occurrences are updated as new records and information become available. The NAS database allows resource managers to learn of new introductions reported in their region or nearby regions, improving response time. Conversely, managers are encouraged to report their observations of new occurrences to the NAS database so information can be disseminated to other managers, researchers, and the public. In May 2004, the NAS database incorporated an Alert System to notify registered users of new introductions as part of a national early detection/rapid response system. Users can register to receive alerts based on geographic or taxonomic criteria. The NAS database was used to identify 23 fish species introduced into the lower Tennessee and Cumberland drainages. Most of these are sport fish stocked to support fisheries, but the list also includes accidental and illegal introductions such as Asian Carps, clupeids, various species popular in the aquarium trade, and Atlantic

  16. Steam Turbine Materials and Corrosion

    Energy Technology Data Exchange (ETDEWEB)

    Holcomb, G.H.; Hsu, D.H.

    2008-07-01

    Ultra-supercritical (USC) power plants offer the promise of higher efficiencies and lower emissions. Current goals of the U.S. Department of Energy’s Advanced Power Systems Initiatives include coal generation at 60% efficiency, which would require steam temperatures of up to 760 °C. In prior years this project examined the steamside oxidation of alloys for use in high- and intermediate-pressure USC turbines. This steamside oxidation research is continuing and progress is presented, with emphasis on chromia evaporation.

  17. Solar steam generation: Steam by thermal concentration

    Science.gov (United States)

    Shang, Wen; Deng, Tao

    2016-09-01

    The solar-driven generation of water steam at 100 °C under one sun normally requires the use of optical concentrators to provide the necessary energy flux. Now, thermal concentration is used to raise the vapour temperature to 100 °C without the need for costly optical concentrators.

  18. 电厂过热汽温串级系统的约束预测控制%Cascade Constrained Model Predictive Control for Power Plant Superheated Steam Temperature System

    Institute of Scientific and Technical Information of China (English)

    冯建苗; 李少远

    2011-01-01

    Power plant superheated steam temperature system is characterized by large inertia and large lag.Usually spray system is applied to form a cascade control system and cascade PID scheme is usually employed to control superheated steam temperature.The spray valve is subject to physical constraints so that actuator saturation happens because of the set point computed by the outer loop controller.The method of cascade model predictive control was applied.Constrained model predictive control(CMPC) was used to handle constraints and obtain optimal solution with system satisfying the corresponding constraints.In addition,simulation of superheated steam system was realized.%针对实际电厂过热汽温系统中减温水阀门受到物理约束限制,外环控制器计算的设定值造成执行机构饱和从而影响系统性能的问题,提出了串级预测控制算法,并采用约束预测控制算法进行求解,在系统约束范围内求得系统性能的优化解,对电厂过热汽温控制系统进行了仿真论证.仿真结果表明,过热汽温系统控制量能被有效控制在约束范围内,并且系统保持了良好的运行结果.

  19. LMFBR steam generator systems development program progress report

    Energy Technology Data Exchange (ETDEWEB)

    None

    The intent of this program is to investigate methods of producing 2-1/4 Cr-1Mo duplex tubing to meet the structural, thermal/hydraulic and leak detection design requirements of the duplex tube leak detection concept for application on the Demonstration Plant and/or prototype steam generator. The leak detection concept as envisioned for LMFBR steam generator application will be analyzed regarding response to credible leak situations. The results of testing will be used for this analysis. The third fluid system will be conceptually designed including the two plena design adaptations being considered and the advantages and disadvantages of each will be assessed. The test program for the single-tube steam generator model will be developed in accordance with the technical and schedular objectives of the LMFBR duplex tube steam generator development program. A conceptual steam generator configuration will be established for use as a reference in the on-going feasibility studies and Demo Plant system development.

  20. 76 FR 5820 - Record of Decision for the General Management Plan for the Cumberland Gap National Historical...

    Science.gov (United States)

    2011-02-02

    ... National Park Service Record of Decision for the General Management Plan for the Cumberland Gap National... the Record of Decision for the General Management Plan Environmental Impact Statement for the..., the National Park Service (NPS) announces the availability of the Record of Decision (ROD) for the...

  1. Forecasting Forest Type and Age Classes in the Appalachian-Cumberland Subregion of the Central Hardwood Region

    Science.gov (United States)

    David N. Wear; Robert Huggett

    2011-01-01

    This chapter describes how forest type and age distributions might be expected to change in the Appalachian-Cumberland portions of the Central Hardwood Region over the next 50 years. Forecasting forest conditions requires accounting for a number of biophysical and socioeconomic dynamics within an internally consistent modeling framework. We used the US Forest...

  2. Application of perturbation methods for sensitivity analysis for nuclear power plant steam generators; Aplicacao da teoria de perturbacao a analise de sensibilidade em geradores de vapor de usinas nucleares

    Energy Technology Data Exchange (ETDEWEB)

    Gurjao, Emir Candeia

    1996-02-01

    The differential and GPT (Generalized Perturbation Theory) formalisms of the Perturbation Theory were applied in this work to a simplified U-tubes steam generator model to perform sensitivity analysis. The adjoint and importance equations, with the corresponding expressions for the sensitivity coefficients, were derived for this steam generator model. The system was numerically was numerically solved in a Fortran program, called GEVADJ, in order to calculate the sensitivity coefficients. A transient loss of forced primary coolant in the nuclear power plant Angra-1 was used as example case. The average and final values of functionals: secondary pressure and enthalpy were studied in relation to changes in the secondary feedwater flow, enthalpy and total volume in secondary circuit. Absolute variations in the above functionals were calculated using the perturbative methods, considering the variations in the feedwater flow and total secondary volume. Comparison with the same variations obtained via direct model showed in general good agreement, demonstrating the potentiality of perturbative methods for sensitivity analysis of nuclear systems. (author) 22 refs., 7 figs., 8 tabs.

  3. Production of primary materials for duro-plastic glue, ethanol, and enzymes, from lignocellulose-containing by-products and organic waste in the Fritz-Werner pilot plant (steam pressure extraction)

    Energy Technology Data Exchange (ETDEWEB)

    Sinner, M.; Langer, J.

    1983-01-01

    By the steam pressure extraction process ligno-cellulose-containing annual plants and deciduous wood can be pulped without the need for chemicals. The pre-ground material is treated continuously with saturated steam at elevated pressures in a boiler for approx. 10-20 min. and is shredded upon discharge from the boiler by reduction of pressure to atmospheric conditions. This decomposition process leads to a softening of the cell wall bonds thereby exposing the bio-structure. Extraction of the fibrous material with water or strongly diluted aqueous alkali gives rise to the hemicellular form of the starting material, in particular to soluble xylane degradation products. The extracted fibrous material consists chiefly of cellulose and lignin. These fibres are so loosely inter-connected that they are readily accessible for chemical and in particular biochemical reaction. The fibres can be converted to glucose by enzymatic or acid hydrolysis, they can be used as a substrate for microorganisms, or as energy source and raw fodder for ruminants, or they can be compressed to form fibre-board without the need for binding agents.

  4. Numerical investigation of mass transfer in the flow path of the experimental model of the PGV-1500 steam generator's steam receiving section with two steam nozzles

    Science.gov (United States)

    Golibrodo, L. A.; Krutikov, A. A.; Nadinskii, Yu. N.; Nikolaeva, A. V.; Skibin, A. P.; Sotskov, V. V.

    2014-10-01

    The hydrodynamics of working medium in the steam volume model implemented in the experimental setup constructed at the Leipunskii Institute for Physics and Power Engineering was simulated for verifying the procedure of calculating the velocity field in the steam space of steam generators used as part of the reactor plants constructed on the basis of water-cooled water-moderated power-generating reactors (VVER). The numerical calculation was implemented in the environment of the STAR-CCM+ software system with its cross verification in the STAR-CD and ANSYS CFX software systems. The performed numerical investigation served as a basis for substantiating the selection of the computation code and parameters for constructing the computer model of the steam receiving device of the PGV-1500 steam generator experimental model, such as the quantization scheme, turbulence model, and mesh model.

  5. 基于火电站汽轮机标准化安装过程的动态仿真研究%Dynamic Simulation Research Based on the Steam Turbine Standardization Installation Process of Power Plant

    Institute of Scientific and Technical Information of China (English)

    李少华; 张庆喆; 车德勇; 王虎

    2013-01-01

    随着电力工业的快速发展,600MW和1 000MW等大型火电机组越来越多,并已成为主力发电机组,针对大型火电站汽轮机安装过程的复杂性,利用三维可视化仿真技术对整个火电站汽轮机安装过程进行三维动态仿真,并辅以图形、语音、文字等多媒体方式说明施工过程中的施工方法、施工工艺、技术标准等,构建汽轮机安装过程标准化方案,开发“火电站汽轮机建设过程仿真系统”.系统的开发对于汽轮机施工行业确定科学的施工方法、运用先进的工艺技术以及培养高素质的施工队伍具有重要的意义,并极大地促进了汽轮机施工行业的科技进步.%Following the rapid development of the power industry,600MW and 1000MW thermal power units are more and more,and has become the main generator sets,Aiming at the complexity of the installation process for steam turbine,3-D visualization techniques was used dynamic simulation of the entire power plant steam turbine installation process,Supplemented by graphics,voice,text and other multimedia means that every installation process of the construction method,construction technology,technical standards etc,Building thermal power station civil construction process standardizationconstruction scheme,Development the steam turbine installation process of 3-D visualization dynamic simulation system.The development of the system for steam turbine construction industry determine scientific construction method,using advanced technology and cultivate high-quality construction team has an important meaning,and greatly promoted the turbine construction industry science and technology progress.

  6. Fourth international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Tuomisto, H. [ed.] [IVO Group, Vantaa (Finland); Purhonen, H. [ed.] [VTT, Espoo (Finland); Kouhia, V. [ed.] [Lappeenranta Univ. of Technology (Finland)

    1997-12-31

    The general objective of the International Seminars of Horizontal Steam Generator Modelling has been the improvement in understanding of realistic thermal hydraulic behaviour of the generators when performing safety analyses for VVER reactors. The main topics presented in the fourth seminar were: thermal hydraulic experiments and analyses, primary collector integrity, feedwater distributor replacement, management of primary-to-secondary leakage accidents and new developments in the VVER safety technology. The number of participants, representing designers and manufacturers of the horizontal steam generators, plant operators, engineering companies, research organizations, universities and regulatory authorities, was 70 from 10 countries.

  7. Experimental research of heterogeneous nuclei in superheated steam

    Directory of Open Access Journals (Sweden)

    Bartoš Ondřej

    2016-01-01

    Full Text Available A mobile steam expansion chamber has been developed to investigate experimentally homogeneous and heterogeneous nucleation processes in steam, both in the laboratory and at power plants using the steam withdrawn from the steam turbine. The purpose of the device is to provide new insight into the physics of nonequilibrium wet steam formation, which is one of the factors limiting the efficiency and reliability of steam turbines. The expanded steam or a mixture of steam with a non-condensable gas rapidly expands in the expansion chamber. Due to adiabatic cooling, the temperature drops below the dew point of the steam at a given pressure. When reaching a sufficiently high supersaturation, droplets are nucleated. By tuning the supersaturation in the so-called nucleation pulse, particles of various size ranges can be activated. This fact is used in the present study to measure the aerosol particles present in the air. Homogeneous nucleation was negligible in this case. The experiment demonstrates the functionality of the device, data acquisition system and data evaluation methods.

  8. Experimental research of heterogeneous nuclei in superheated steam

    Science.gov (United States)

    Bartoš, Ondřej; Kolovratník, Michal; Šmíd, Bohuslav; Hrubý, Jan

    2016-03-01

    A mobile steam expansion chamber has been developed to investigate experimentally homogeneous and heterogeneous nucleation processes in steam, both in the laboratory and at power plants using the steam withdrawn from the steam turbine. The purpose of the device is to provide new insight into the physics of nonequilibrium wet steam formation, which is one of the factors limiting the efficiency and reliability of steam turbines. The expanded steam or a mixture of steam with a non-condensable gas rapidly expands in the expansion chamber. Due to adiabatic cooling, the temperature drops below the dew point of the steam at a given pressure. When reaching a sufficiently high supersaturation, droplets are nucleated. By tuning the supersaturation in the so-called nucleation pulse, particles of various size ranges can be activated. This fact is used in the present study to measure the aerosol particles present in the air. Homogeneous nucleation was negligible in this case. The experiment demonstrates the functionality of the device, data acquisition system and data evaluation methods.

  9. Neuro-fuzzy generalized predictive control of boiler steam temperature

    Institute of Scientific and Technical Information of China (English)

    Xiangjie LIU; Jizhen LIU; Ping GUAN

    2007-01-01

    Power plants are nonlinear and uncertain complex systems.Reliable control of superheated steam temperature is necessary to ensure high efficiency and high load-following capability in the operation of modern power plant.A nonlinear generalized predictive controller based on neuro-fuzzy network(NFGPC)is proposed in this paper.The proposed nonlinear controller is applied to control the superheated steam temperature of a 200MW power plant.From the experiments on the plant and the simulation of the plant,much better performance than the traditional controller is obtained.

  10. 某电厂汽轮机低压缸隔板断裂失效原因分析%Failure Analysis for Diaphragm Fracture of LP Cylinder of Steam Turbine in a Power Plant

    Institute of Scientific and Technical Information of China (English)

    刘金状

    2014-01-01

    The fracture of a gray cast-iron diaphragm in LP cylinder of steam turbine in a power plant was analyzed by means of metallographic test, hardness test and structure analysis. The results suggest that it is normal for microstructure or hardness. Fracture is mainly caused by the stress concentration due to unreasonable structural design. Meanwhile, the proposal for repair welding of gray cast iron diaphragm is put forward.%对某火力发电厂断裂的汽轮机组铸铁隔板进行了金相组织观察、硬度测试和机械结构分析。结果表明隔板的断裂主要是结构设计不合理引起的应力集中造成的。同时,对该铸件的焊接修复提出了合理化建议。

  11. HVOF coatings for steam oxidation protection

    Energy Technology Data Exchange (ETDEWEB)

    Agueero, A.; Muelas, R.; Gonzalez, V. [Instituto Nacional de Tecnica Aeroespacial (INTA), Area de Materiales Metalicos, Madrid (Spain)

    2008-05-15

    In the context of the European project 'Coatings for Supercritical Steam Cycles' (SUPERCOAT), the use of steam oxidation resistant coatings on currently available ferritic materials with high creep strength but poor oxidation resistance was investigated in order to allow increase in the operating temperature of steam power plants from 550 to 650 C. Among the explored coating techniques for this application, chosen on the basis of being potentially appropriate for coating steam turbine components, High Velocity Oxy Fuel (HVOF) thermal spray has resulted in one of the most successful techniques. Different alloyed materials such as FeCrAl, NiCrSiFeB, FeAl, NiCr and FeCr have been deposited, optimized and tested under flowing steam at 650 C. Characterization of as deposited and tested samples by metallography, SEM-EDS and XRD was carried out. Some of these coatings form protective pure chromium or aluminium oxides exhibiting excellent behaviour for at least 15 000 h of exposure, whereas others form less stable complex mixed oxides which nevertheless grow at considerably slower rates than the oxides formed on uncoated P92 (9 wt%Cr ferritic steel). (Abstract Copyright [2008], Wiley Periodicals, Inc.)

  12. Ciclo combinado Diesel-Vapor como repotenciación de una central termoeléctrica: caso de estudio; Combined Cycle Diesel-Steam as Power Plant Repowering: study case

    Directory of Open Access Journals (Sweden)

    Alberto Eduardo Calvo González

    2014-06-01

    Full Text Available La necesidad imperiosa de cubrir el déficit de generación eléctrica ampliando el potencial de generación con motores diesel a fuel oíl, cuya instalación requiere de muy poco tiempo, es una solución adecuada. La idea de aprovechar los nodos del sistema electro energético, como son las subestaciones y las centrales eléctricas, para instalar los grupos electrógenos es una solución apropiada. Pero en el caso de una central termoeléctrica, al montar estas instalaciones de forma independiente, no se aprovechan las posibilidades que la combinación de procesos ofrece como la disminución del consumo de combustible, y de la contaminación ambiental por unidad de energía producida. El presente trabajo explora la posibilidad de instalar plantas eléctricas diesel a fuel oil como ciclo combinado diesel-vapor. Se demuestra la conveniencia de instalar plantas eléctricas diesel a fuel oil como ciclo combinado diesel-vapor, aprovechando la sinergia que se logra por la combinación de los procesos térmicos. The pressing need of covering generation deficit to satisfy the demand in the shorter possible time, by enlarging the generation potential with fuel oil fueled diesel motors, it’s an appropriate solution. The idea of taking advantage of electric grid existent nodes facilities to place the generating electricity diesel motors is a non-unwise solution. But in the case of the node of steam power station place these motors in an independent way, don't take advantage of the possibilities that the processes combination offers, as the combined cycle diesel vapor for example. The work presented herein explored and showed the possibility of installing the electric diesel plants as a repowering the existing steam power plant by combined cycle diesel-steam taking advantage of the synergy achieved by thermal processes combination.

  13. The role of the chemist/chemical engineer for the trouble-free operation of thermal plants with heat recovery steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Addison, David; Weir, Judy [Thermal Chemistry Limited, Horsham Downs, Hamilton (New Zealand)

    2012-06-15

    The importance of a chemist/chemical engineer for the reliable and efficient operation of combined cycle gas turbine (CCGT) plants is discussed along with the key differences between routine and strategic chemistry and how these potentially impact on CCGT plant operation. Potential risks and issues with the full outsourcing of cycle chemistry services for a CCGT plant to chemical service providers are outlined. Also discussed are the interactions between a chemist/chemical engineer and plant management, operations, engineering and maintenance personnel. Proposed chemist/chemical engineer staffing levels for a number of hypothetical CCGT plants are also discussed. (orig.)

  14. The VGB guidelines for organic matter and dissolved carbon dioxide in the steam/water cycle of power plant; VGB-Richtlinien fuer Organica und geloeste Kohlensaeure im Wasser-Dampf-Kreislauf von Kraftwerken. Die Kraftwerkschemie betrifft wieder Neuland

    Energy Technology Data Exchange (ETDEWEB)

    Aspden, J.D. [Eskom Chemistry and Auxiliary Plant Engineering, Johannesburg (South Africa); Bellows, J.C. [Siemens Westinghouse Power Corp., Orlando, FL (United States); Hein, M. [PreussenElektra AG, Grosskrotzenburg (Germany). Kraftwerk Staudinger; Huber, S. [DOC-Labor, Karlsruhe (Germany); Maughan, E.V. [College of Knowledge, Duisburg (Germany); Pflug, H.D.; Rziha, M. [Siemens AG Unternehmensbereich KWU, Erlangen (Germany); Seipp, H.G. [ABB Kraftwerke AG, Mannheim (Germany). Hauptabteilung Technikdienste; Svoboda, R. [ABB Power Generation Ltd., Baden (Switzerland). Power Plant Chemistry; Woost, O. [Solvay Alkali Bernburg GmbH (Germany); Zeijseink, A.G.L. [KEMA Power Generation, Arnheim (Netherlands)

    2000-07-01

    Power plant chemists have concentrated mainly on inorganic contaminants and corrosion protection agents when monitoring the plant cycle chemistry. However, in recent years the focus has shifted to organic matter and its impact on the materials in the steam/water cycle. A VGB Working Group has been established to collect information on a global basis for the compilation of a set of guidelines for organic matter and dissolved carbon dioxide in plant cycle chemistry. (orig.) [German] Kraftwerkschemiker sahen bisher in der Online-Messtechnik vornehmlich eine Moeglichkeit, im Wasser-Dampf-Kreislauf des Auftreten anorganischer Kontaminanten sowie die Konzentration von Korrosionsschutzmitteln zu ueberwachen. Seit ein paar Jahren jedoch gilt das Interesse auch organischen Verunreinigungen und deren moeglichem schaedigendem Einfluss auf Komponenten in der Dampf-Wasser-Phase. Eine VGB-Arbeitsgruppe wurde ins Leben gerufen, um weltweit Fachliteratur, Erfahrungsberichte und sonstige relevante Hinweise auf das Thema zusammenzutragen und auszuwerten. Ziel ist die Erarbeitung einer Richtlinie zu organischen Stoffen (Organica) und geloestem Kohlendioxid im Wasser-Dampf-Kreislauf. (orig.)

  15. Population viability analysis to identify management priorities for reintroduced elk in the Cumberland Mountains, Tennessee

    Science.gov (United States)

    Kindall, J.L.; Muller, L.I.; Clark, J.D.; Lupardus, J.L.; Murrow, J.L.

    2011-01-01

    We used an individual-based population model to perform a viability analysis to simulate population growth (λ) of 167 elk (Cervus elaphus manitobensis; 71 male and 96 female) released in the Cumberland Mountains, Tennessee, to estimate sustainability (i.e., λ > 1.0) and identify the most appropriate options for managing elk restoration. We transported elk from Elk Island National Park, Alberta, Canada, and from Land Between the Lakes, Kentucky, and reintroduced them beginning in December 2000 and ending in February 2003. We estimated annual survival rates for 156 radio-collared elk from December 2000 until November 2004. We used data from a nearby elk herd in Great Smoky Mountains National Park to simulate pessimistic and optimistic recruitment and performed population viability analyses to evaluate sustainability over a 25-year period. Annual survival averaged 0.799 (Total SE = 0.023). The primary identifiable sources of mortality were poaching, disease from meningeal worm (Parelaphostrongylus tenuis), and accidents (environmental causes and unintentional harvest). Population growth given pessimistic recruitment rates averaged 0.895 over 25 years (0.955 in year 1 to 0.880 in year 25); population growth was not sustainable in 100% of the runs. With the most optimistic estimates of recruitment, mean λ increased to 0.967 (1.038 in year 1 to 0.956 in year 25) with 99.6% of the runs failing to be sustainable. We suggest that further translocation efforts to increase herd size will be ineffective unless survival rates are increased in the Cumberland Mountains.

  16. Steam reforming of technical bioethanol for hydrogen production

    DEFF Research Database (Denmark)

    Rass-Hansen, Jeppe; Johansson, Roger; Møller, Martin Hulbek;

    2008-01-01

    Essentially all work on ethanol steam reforming so far has been carried out using simulated bioethanol feedstocks, which means pure ethanol mixed with water. However, technical bioethanol consists of a lot of different components including sugars, which cannot be easily vaporized and steam reformed....... For ethanol steam reforming to be of practical interest, it is important to avoid the energy-intensive purification steps to fuel grade ethanol. Therefore, it is imperative to analyze how technical bioethanol, with the relevant impurities, reacts during the steam reforming process. We show how three different...... distillation fractions of technical 2nd generation bioethanol, produced in a pilot plant, influence the performance of nickel- and ruthenium-based catalysts during steam reforming, and we discuss what is required to obtain high activity and long catalyst lifetime. We conclude that the use of technical...

  17. Modelling of Steam Generating Paraboloidal dish Solar Thermal Power System

    Energy Technology Data Exchange (ETDEWEB)

    Siangsukone, P.; Lovegrove, K.

    2006-07-01

    The Australian National University (ANU) has a 400m2 Paraboloidal dish solar concentrator system, informally named the Big Dish that produces superheated steam via a receiver mounted monotube boiler connected to 50kWe steam engine for electricity generation. This paper describes an investigation of the system and its components modelled using the TRNYSYS transient system simulation package. The system was modelled in the context of performance assessment for multiple dishes, central generation Rankine cycle power plants. Five new custom components; paraboloidal dish collector, steam cavity receiver, steam line or feedwater line, steam engine, and pressure drop calculator, were developed for the TRNSYS deck file constructed for this study. Validation tests were performed by comparing with the latest experimental results measured with a 1-minute time step and good agreement, with errors less than 10%, has been found. (Author)

  18. RPV steam generator pressure boundary

    Energy Technology Data Exchange (ETDEWEB)

    Strosnider, J.

    1996-03-01

    As the types of SG tube degradation affecting PWR SGs has changed, and improvements in tube inspection and repair technology have occurred, current SG regulatory requirements and guidance have become increasingly out of date. This regulatory situation has been dealt with on a plant-specific basis, however to resolve this problem in the long term, the NRC has begun development of a performance-based rule. As currently structured, the proposed steam generator rule would require licensees to implement SG programs that monitor the condition of the steam generator tubes against accepted performance criteria to provide reasonable assurance that the steam generator tubes remain capable of performing their intended safety functions. Currently the staff is developing three performance criteria that will ensure the tubes can continue to perform their safety function and therefore satisfy the SG rule requirements. The staff, in developing the criteria, is striving to ensure that the performance criteria have the two key attributes of being (1) measurable (enabling the tube condition to be {open_quotes}measured{close_quotes} against the criteria) and (2) tolerable (ensuring that failures to meet the criteria do not result in unacceptable consequences). A general description of the criteria are: (1) Structural integrity criteria: Ensures that the structural integrity of the SG tubes is maintained for the operating cycle consistent with the margins intended by the ASME Code. (2) Leakage integrity criteria: Ensures that postulated accident leakages and the associated dose releases are limited relative to 10 CFR Part 50 guidelines and 10 CFR Part 50 Appendix A GDC 19. (3) Operational leakage criteria: Ensures that the operating unit will be shut down as a defense-in depth measure when operational SG tube leakage exceeds established leakage limits.

  19. The condensation of steam from steam-water mixture on water jets at high pressure

    Science.gov (United States)

    Somova, E. V.; Kisina, V. I.; Shvarts, A. L.; Kolbasnikov, A. V.; Kanishchev, V. P.

    2009-01-01

    A physical model for condensation of steam in water flow at high pressure is developed, and analytical dependences for calculating heat transfer are obtained, in particular as applied to the operation of a direct-contact feedwater heater for a new-generation reactor plant with lead coolant.

  20. The criterion for blanking-off heat-transfer tubes in the steam generators at VVER-based nuclear power plants based on the results of eddy-current examination

    Science.gov (United States)

    Lunin, V. P.; Zhdanov, A. G.; Chegodaev, V. V.; Stolyarov, A. A.

    2015-05-01

    The problem of defining the criterion for blanking off heat-transfer tubes in the steam generators at nuclear power plants on the basis of signals obtained from the standard multifrequency eddy-current examination is considered. The decision about blanking off one or another tube is presently made with reference to one parameter of the relevant signal at the working frequency, namely, with reference to its phase, which directly depends on the depth of the flaw being detected, i.e., a crack in the tube. The crack depth equal to 60% of the tube wall thickness is regarded to be the critical one, at which a decision about withdrawing such a tube out from operation (blanking off) must be taken. However, since mechanical tensile rupture tests of heat-transfer tubes show the possibility of their further use with such flaws, the secondary parameter of the signal, namely, its amplitude, must be used for determining the blanking-off criterion. The signals produced by the standard flow-type transducers in response to flaws in the form of a longitudinal crack having the depth and length within the limits permitted by the relevant regulations were calculated using 3D finite-element modeling. Based on the obtained results, the values of the eddy-current signal amplitude were determined, which, together with the signal phase value, form a new amplitude-phase criterion for blanking off heat-transfer tubes. For confirming the effectiveness of this technique, the algorithm for revealing the signal indications satisfying the proposed amplitude-phase criterion was tested on real signals obtained from operational eddy-current examination of the state of steam generator heat-transfer tubes carried out within the framework of planned preventive repair.

  1. 76 FR 48722 - Endangered and Threatened Wildlife and Plants; Endangered Status for the Cumberland Darter, Rush...

    Science.gov (United States)

    2011-08-09

    ...Creary Counties, Kentucky, and Campbell and Scott Counties, Tennessee. These studies suggested the... Kentucky (McCreary and Whitley Counties) and Tennessee (Campbell and Scott Counties). All 15 extant... conducted. While nothing is known specifically about chucky madtom reproductive biology, recruitment,...

  2. 77 FR 63603 - Endangered and Threatened Wildlife and Plants; Designation of Critical Habitat for the Cumberland...

    Science.gov (United States)

    2012-10-16

    ... McCreary and Whitley Counties, Kentucky, and Campbell and Scott Counties, Tennessee; 44 rkm (27 rmi... on the biology and ecology of these five fishes, refer to the final listing rule published in the... and Whitley Counties, Kentucky, and Campbell and Scott Counties, Tennessee (Thomas 2007, pp....

  3. STEAM GENERATOR GROUP PROJECT

    Energy Technology Data Exchange (ETDEWEB)

    Clark, R. A.; Lewis, M

    1985-09-01

    This report is a summary of progress in the Surry Steam Generator Group Project for 1984. Information is presented on the analysis of two baseline eddy current inspections of the generator. Round robin series of tests using standard in-service inspection techniques are described along with some preliminary results. Observations are reported of degradation found on tubing specimens removed from the generator, and on support plates characterized in-situ. Residual stresses measured on a tubing specimen are reported. Two steam generator repair demonstrations are described; one for antivibration bar replacement, and one on tube repair methods. Chemical analyses are shown for sludge samples removed from above the tube sheet.

  4. Boiler tube failures in industrial drum-type steam generators. Pt. 3: Alternative cycle chemistry treatments

    Energy Technology Data Exchange (ETDEWEB)

    Bursik, A. [University of Stuttgart (Germany)

    2002-12-01

    This part (the third part of a four-part publication) discusses the applicability of amine-based plant cycle treatments which are covered neither by the VGB Guideline for Boiler Feedwater, Boiler Water, and Steam of Steam Generators with a Permissible Operating Pressure of >6.8 MPa nor by the set of EPRI Cycle Chemistry Guidelines for Fossil Plants. (orig.)

  5. Lifetime Assessment of a Steam Pipeline

    Directory of Open Access Journals (Sweden)

    Jiří Janovec

    2012-01-01

    Full Text Available The aim of this paper is to design a method for assessing the life of steam pipes for Czech power plants. The most widely-used material in Czech power plants is steel 15 128. Our findings may also be applied for international equivalents of this steel. The paper shows the classification of cavitation damage and microstructure classification status, based on the German VGB Act, with references to EPRI law in the USA. Calculations of remaining life on the basis of Russian experience are also shown. The possibility of applying this method to increase the operating parameters for power plants is discussed.

  6. Steam turbines and operation of steam turbines 2010. Proceedings; Dampfturbinen und Dampfturbinenbetrieb 2010. Tagungsband

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    2010-07-01

    Within the VGB conference an 30th June to 1st July, 2010 in Luebeck (Federal Republic of Germany) the following lectures were held: (1) Application of rifled tubes in power plant heat exchangers (Andreas Grahl); (2) Improved efficiency and potential savings at the 'cool end' through tube cleaning and cooling water filtration (Wolfgang Czolkoss); (3) Material and process improvements in condenser tubing (Pascal Gerard); (4) Automatic eddy current testing of longitudinally welded austentic and titanium tubes for condensers and other heat exchanger (Werner Hannig); (5) Major steam turbine losses: causes, repair measures, recommissioning (Stefan Thumm); (6) Damage on industrial steam turbines (Hans-Guenter Busch); (7) Proper design of turbine draining systems (Ralph Semme); (8) VDMA - Contribution to functional safety of turbomachinery - Required risk reduction by safety functions for steam turbines (Bernhard Wuest); (9) Functional safety by MAN turbo on the example of SIL3 safety loop overspeed detection (Holger Buschmann); (10) Boiler feed pump monitoring, diagnostic and controlling loop (Sohail Ahmed); (11) Experimental investigation to the radial adjustment of brush seals for steam turbines (Heiko Schwarz); (12) The revised VGB guidelines for condenser tubes from copper alloys, stainless steels and titanium (Frank-Udo Leidich); (13) Modernization of HP and LP turbines in coal-fired power plant Bergkamen (Roland Sommer); (14) Mega-components made of cast steel for power plant technology (Reinhold Hanus); (15) Quality monitoring of steam turbine sets for new construction projects of the Vattenfall Europe Generation AG (Marco Rediess); (16) Weld repair of a cracked LP rotor (Andreas Nowi); (17) Steam turbines and CO{sub 2} sequestration (Juergen Klebes); (18) Advanced filter element construction for alleviating electrostatic discharge effects in turbine lubricating systems (John K. Duchowski).

  7. Development and design of advanced heat recovery steam generator

    Energy Technology Data Exchange (ETDEWEB)

    Peral, V.; Roa, A. [Babcock & Wilcox Espanola (Spain)

    1998-12-31

    The work carried out investigated: cycle considerations, pressure dependence between superheater and reheater and the condenser vacuum pressure; boiler restrictions by pinch points and heat available; and boiler design. The starting point was based on design experience of IGCC power plant at Puertollano. In this case, the heat recovery boiler has been designed for two fuel types: mixed coal and natural gas. The design of the boiler is in agreement with these two cases achieving highest steam temperature with natural gas and due to high pressure steam imported, the steam flow and pressure to turbine is higher with mixed coal + petroleum coke. The last section provides the construction data. 6 figs.

  8. Predicted Effects of Hydropower Uprate on Trout Habitat in the Cumberland River, Downstream of Wolf Creek Dam, Kentucky

    Science.gov (United States)

    1988-08-01

    was similar to the approach discussed in the previous section, except that the WSP model was replaced by a one-dimensional dynamic flow model, BIRM ...modifications of PHABSIM were required for the Cumberland River analysis. The unsteady flow code ( BIRM ) used in this application can be replaced by any...other dynamic, one-dimensional riverine hydraulic code that is capable of providing stage-discharge information to the IFG-4 program. The BIRM output

  9. A Field Study of the Fates of Arsenal and Escort Applied on the Cumberland Plateau in Tennessee

    Directory of Open Access Journals (Sweden)

    John Harwood

    2010-01-01

    Full Text Available Problem statement: The low organic soils of the Cumberland Plateau, as well as the karst geology of the region, may promote increased transport of herbicides outside of application sites. We have studied the fates of imazapyr and metsulfuron-methyl applied to a privately owned tract on the Cumberland Plateau in Tennessee and compared the field results with herbicide fate predicted by the computer model GLEAMS. Approach: The fate of the two herbicides, applied for pine release at a site on the Cumberland Plateau, was monitored over a sixteen month period. Concentrations in soil water were monitored using vacuum soil lysimeters. Grab samples were taken of water in ephemeral streams draining the clearcut area and of a perennial stream which receives water from the study area. Uncut streamside management zones of about 50 m bordered the streams. The field results were compared with those obtained using the GLEAMS computer model. Results: Concentrations of both herbicides in soil water dropped significantly within the first two months after application, imazapyr to less than 50 µg L-1 and metsulfuron methyl to less than 3 µg L-1 and decreased more gradually in the following months. The maximum concentrations observed in soil water were 252 µg L-1 (imazapyr and 13 µg L-1 (metsulfuron methyl. Except on two dates occurring 5 months after application, the herbicides were not detected in the stream samples. GLEAMS predicted that very little herbicide should have been lost from the site in runoff or erosion sediment. The model predicted greater retention of the herbicides by the soil than was found through the field measurements. Conclusion/Recommendation: The rapid transport of imazapyr and metsulfuron we observed indicates that further study is justified at other locations on the Cumberland Plateau. Streamside management zones effectively prohibited contamination of receiving streams by herbicides at the study site.

  10. CFDB Steam Heat Conduction Oil Composite Boiler Application in Dyeing and Finishing Plant%循环双流化床蒸汽导热油复合锅炉在染整厂的应用

    Institute of Scientific and Technical Information of China (English)

    林金辉

    2016-01-01

    The paper discuss about the principle, structure and advantages of the one new type and high efficient boiler-CFDB steam heat conduction oil composite boiler, what's more, the boiler has the case in dyeing and finishing plant that it has been built and running. Through practical testing, it can bring certain economic benefits, environmental benefits and social benefits, and make some reference for dyeing and finishing plant boiler system integration.%本文对一种新型高效锅炉-循环双流化床蒸汽导热油复合锅炉的原理、结构及优点做了论述,且该型锅炉已在染整厂有实例建成投入运行,通过实践检验,它能够带来一定的经济效益、环保效益和社会效益,为染整厂锅炉系统整合有一定借鉴作用。

  11. Discussion on Flue Gas Waste Heat Utilization technology of Heavy(F Class)Gas-steam Combined Cycle Power Plant%大型F级燃气蒸汽联合循环烟气余热利用探讨

    Institute of Scientific and Technical Information of China (English)

    章正传; 殷俊; 李懿靓

    2014-01-01

    本文探讨了大型F级联合循环机组利用烟气余热进行凝结水/给水加热、燃料气加热,进气冷却,以及利用烟气余热制冷和采暖方面的应用,分析表明,大型联合循环电厂烟气余热利用潜力较大,充分利用烟气余热,具有一定的节能意义。%This paper discusses flue gas waste heat utilization of Heavy(F Class)Gas- steam Combined Cycle Power Plant ,which used in condensed water /feed water heating, fuel gas heating, air cooling, and refrigeration and heating. Analysis shows that, the large combined cycle power plant flue gas waste heat utilization potential, make full use of the waste heat of the flue gas, has certain significance of energy saving.

  12. Quantification of subaerial and episodic subglacial erosion rates on high latitude upland plateaus: Cumberland Peninsula, Baffin Island, Arctic Canada

    Science.gov (United States)

    Margreth, Annina; Gosse, John C.; Dyke, Arthur S.

    2016-02-01

    Long-term rates of subaerial and episodic subglacial erosion by predominately cold-based ice cover are determined for tors on weathered plateaus on Cumberland Peninsula. By measuring terrestrial cosmogenic nuclide concentrations in differentially weathered surfaces on a given tor, we reconstruct the complex exposure and erosion history involving recurring cold-based ice cover. The style and rate of subaerial and subglacial erosion at multiple tor sites on Cumberland Peninsula are assessed with a Monte Carlo approach that computes plausible exposure histories based on a proxy record of global ice volume. Constant subaerial erosion rates by weathering are low (tors located on coastal ridge crests that have likely never been glaciated. Summit plateaus intermittently covered by cold-based ice throughout the Quaternary have experienced episodic subglacial erosion by plucking of fractured bedrock with rates between 1 and 16 mm ka-1. Variation of episodic erosion rates is associated with topographic position of the sampled tors and bedrock fracture density. Most of the tors were last glacially plucked in pre-ultimate glaciations, not during the Wisconsinan glaciation. Furthermore, the new approach provides evidence for the extent of ice coverage during the late Wisconsinan, which is significant if no erratics are available for exposure dating. Despite late Pleistocene intervals of ice cover and glacial plucking, tor-studded landscapes of Cumberland Peninsula are of considerable antiquity.

  13. Development of data management system for steam generator inspection

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yong Moo; Im, Chang Jae; Lee, Yoon Sang; Kang, Soon Joo; An, Jong Kwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    The data communications environment for transferring Nuclear Power Plant Steam Generator Eddy Current testing data was investigated and after connecting LAN to Hinet-F network, the remote data transfer with the speed of 56 kbps was tested successfully. Data management system for Steam Generator Eddy current testing was also developed by using HP-UX, RMB (Rock Mountain Basic) 21 figs, 13 tabs, 5 refs. (Author).

  14. MINET validation study using steam generator test data

    Energy Technology Data Exchange (ETDEWEB)

    Van Tuyle, G.J.; Guppy, J.G.

    1984-01-01

    Three steam generator transient test cases that were simulated using the MINET computer code are described, with computed results compared against experimental data. The MINET calculations closely agreed with the experiment for both the once-through and the U-tube steam generator test cases. The effort is part of an ongoing effort to validate the MINET computer code for thermal-hydraulic plant systems transient analysis, and strongly supports the validity of the MINET models.

  15. Development of data management system for steam generator inspection

    Energy Technology Data Exchange (ETDEWEB)

    Jung, Yong Moo; Im, Chang Jae; Lee, Yoon Sang; Kang, Soon Joo; An, Jong Kwan [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1994-06-01

    The data communications environment for transferring Nuclear Power Plant Steam Generator Eddy Current testing data was investigated and after connecting LAN to Hinet-F network, the remote data transfer with the speed of 56 kbps was tested successfully. Data management system for Steam Generator Eddy current testing was also developed by using HP-UX, RMB (Rock Mountain Basic) 21 figs, 13 tabs, 5 refs. (Author).

  16. Evaluating the impact of an ammonia-based post-combustion CO2 capture process on a steam power plant with different cooling water temperatures

    DEFF Research Database (Denmark)

    Linnenberg, Sebastian; Darde, Victor Camille Alfred; Oexmann, Jochen

    2012-01-01

    The use of aqueous ammonia is a promising option to capture carbon dioxide from the flue gas of coal-fired power plants. Compared to a capture process using monoethanolamine (MEA), the use of ammonia can reduce the heat requirement of the CO2 desorption significantly, although an additional effort...... is necessary to provide the cooling of the process. To allow for a fair evaluation of the integration of this CO2 capture process into a power plant process, an overall process evaluation is carried out. The use of detailed models of the power plant, of the compressor and of the CO2 capture process enables....... Additionally, two different process configurations of the capture plant, with either one single absorber or two absorbers connected in series where the first absorber captures the majority of the CO2 and the second limits the NH3 slip, are evaluated.The influence of the main process parameters (desorber...

  17. Investigation of the steam-cooled blade in a steam turbine cascade

    Institute of Scientific and Technical Information of China (English)

    Dieter Bohn; Jing Ren; Karsten Kusterer

    2007-01-01

    With the increasing demand for electricity,an efficiency improvement and thereby reduced CO2 emissions of the coal-fired plants are expected in order to reach the goals set in the Kyoto protocol.It can be achieved by a rise of the process parameters.Currently,live steam pressures and temperatures up to 300 bars and 923 K are planned as the next step.Closed circuit steam cooling of blades and vanes in modern steam turbines is a promising technology in order to establish elevated live steam temperatures in future steam turbine cycles.In this paper,a steam-cooled test vane in a cascade with external hot steam flow is analyzed numerically with the in-house code CHTflow.A parametric analysis aiming to improve the cooling effectiveness is carried out by varying the cooling mass flow ratio.The results from two investigated cases show that the steam cooling technique has a good application potential in the steam turbine.The internal part of the vane is cooled homogeneously in both cases.With the increased cooling mass flow rate,there is a significant improvement of cooling efficiency at the leading edge.The results show that the increased cooling mass flow ratio can enhance the cooling effectiveness at the leading edge.With respect to trailing edge,there is no observable improvement of cooling effectiveness with the increased cooling mass flow.This implies that due to the limited dimension at the trailing edge,the thermal stress cannot be decreased by increasing the cooling mass flow rate.Therefore,impingement-cooling configuration at the trailing edge might be a solution to overcome the critical thermal stress there.It is also observed that the performance of the cooling effective differs on pressure side and suction side.It implicates that the equilibrium of the cooling effectiveness on two sides are influenced by a coupled relationship between cooling mass flow ratio and hole geometry.In future work,optimizing the hole geometry and cooling steam supply conditions might

  18. Water Quality Projects Summary for the Mid-Columbia and Cumberland River Systems

    Energy Technology Data Exchange (ETDEWEB)

    Stewart, Kevin M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Witt, Adam M. [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States); Hadjerioua, Boualem [Oak Ridge National Lab. (ORNL), Oak Ridge, TN (United States)

    2017-04-01

    Scheduling and operational control of hydropower systems is accompanied with a keen awareness of the management of water use, environmental effects, and policy, especially within the context of strict water rights policy and generation maximization. This is a multi-objective problem for many hydropower systems, including the Cumberland and Mid-Columbia river systems. Though each of these two systems have distinct operational philosophies, hydrologic characteristics, and system dynamics, they both share a responsibility to effectively manage hydropower and the environment, which requires state-of-the art improvements in the approaches and applications for water quality modeling. The Department of Energy and Oak Ridge National Laboratory have developed tools for total dissolved gas (TDG) prediction on the Mid-Columbia River and a decision-support system used for hydropower generation and environmental optimization on the Cumberland River. In conjunction with IIHR - Hydroscience & Engineering, The University of Iowa and University of Colorado s Center for Advanced Decision Support for Water and Environmental Systems (CADSWES), ORNL has managed the development of a TDG predictive methodology at seven dams along the Mid-Columbia River and has enabled the ability to utilize this methodology for optimization of operations at these projects with the commercially available software package Riverware. ORNL has also managed the collaboration with Vanderbilt University and Lipscomb University to develop a state-of-the art method for reducing high-fidelity water quality modeling results into surrogate models which can be used effectively within the context of optimization efforts to maximize generation for a reservoir system based on environmental and policy constraints. The novel contribution of these efforts is the ability to predict water quality conditions with simplified methodologies at the same level of accuracy as more complex and resource intensive computing methods

  19. Features of steam turbine cooling by the example of an SKR-100 turbine for supercritical steam parameters

    Science.gov (United States)

    Arkadyev, B. A.

    2015-10-01

    Basic principles of cooling of high-temperature steam turbines and constructive solutions used for development of the world's first cooled steam turbine SKR-100 (R-100-300) are described. Principal differences between the thermodynamic properties of cooling medium in the steam and gas turbines and the preference of making flow passes of cooled cylinders of steam turbines as reactive are shown. Some of its operation results and their conclusions are given. This turbine with a power of 100 MW, initial steam parameters approximately 30 MPa and 650°C, and back pressure 3 MPa was made by a Kharkov turbine plant in 1961 and ran successfully at a Kashira GRES (state district power plant) up to 1979, when it was taken out of use in a still fully operating condition. For comparison, some data on construction features and operation results of the super-high pressure cylinder of steam turbines of American Philo 6 (made by General Electric Co.) and Eddystone 1 (made by Westinghouse Co.) power generating units, which are close to the SKR-100 turbine by design initial steam parameters and the implementation time, are given. The high operational reliability and effectiveness of the cooling system that was used in the super-high pressure cylinder of the SKR-100 turbine of the power-generating unit, which were demonstrated in operation, confirms rightfulness and expediency of principles and constructive solutions laid at its development. As process steam temperatures are increased, the realization of the proposed approach to cooling of multistage turbines makes it possible to limit for large turbine parts the application of new, more expensive high-temperature materials, which are required for making steam boilers, and, in some cases, to do completely away with their utilization.

  20. K-65-12.8 condensing steam turbine

    Science.gov (United States)

    Valamin, A. E.; Kultyshev, A. Yu.; Gol'dberg, A. A.; Sakhnin, Yu. A.; Bilan, V. N.; Stepanov, M. Yu.; Polyaeva, E. N.; Shekhter, M. V.; Shibaev, T. L.

    2016-11-01

    A new condensing steam turbine K-65-12.8 is considered, which is the continuation of the development of the steam turbine family of 50-70 MW and the fresh steam pressure of 12.8 MPa, such as twocylinder T-50-12.8 and T-60/65-12.8 turbines. The turbine was developed using the modular design. The design and the main distinctive features of the turbine are described, such as a single two-housing cylinder with the steam flow loop; the extraction from the blading section for the regeneration, the inner needs, and heating; and the unification of some assemblies of serial turbines with shorter time of manufacture. The turbine uses the throttling steam distribution; steam from a boiler is supplied to a turbine through a separate valve block consisting of a central shut-off valve and two side control valves. The blading section of a turbine consists of 23 stages: the left flow contains ten stages installed in the inner housing and the right flow contains 13 stages with diaphragm placed in holders installed in the outer housing. The disks of the first 16 stages are forged together with a rotor, and the disks of the rest stages are mounted. Before the two last stages, the uncontrolled steam extraction is performed for the heating of a plant with the heat output of 38-75 GJ/h. Also, a turbine has five regenerative extraction points for feed water heating and the additional steam extraction to a collector for the inner needs with the consumption of up to 10 t/h. The feasibility parameters of a turbine plant are given. The main solutions for the heat flow diagram and the layout of a turbine plant are presented. The main principles and features of the microprocessor electro hydraulic control and protection system are formulated.

  1. Modelling ecological flow regime: an example from the Tennessee and Cumberland River basins

    Science.gov (United States)

    Knight, Rodney R.; Gain, W. Scott; Wolfe, William J.

    2012-01-01

    Predictive equations were developed for 19 ecologically relevant streamflow characteristics within five major groups of flow variables (magnitude, ratio, frequency, variability, and date) for use in the Tennessee and Cumberland River basins using stepbackward regression. Basin characteristics explain 50% or more of the variation for 12 of the 19 equations. Independent variables identified through stepbackward regression were statistically significant in 78 of 304 cases (α > 0.0001) and represent four major groups: climate, physical landscape features, regional indicators, and land use. Of these groups, the regional and climate variables were the most influential for determining hydrologic response. Daily temperature range, geologic factor, and rock depth were major factors explaining the variability in 17, 15, and 13 equations, respectively. The equations and independent datasets were used to explore the broad relation between basin properties and streamflow and the implication of streamflow to the study of ecological flow requirements. Key results include a high degree of hydrologic variability among least disturbed Blue Ridge streams, similar hydrologic behaviour for watersheds with widely varying degrees of forest cover, and distinct hydrologic profiles for streams in different geographic regions. Published in 2011. This article is a US Government work and is in the public domain in the USA.

  2. Lifetime Assessment of a Steam Pipeline

    OpenAIRE

    Jiří Janovec; Daniela Poláchová; Michal Junek

    2012-01-01

    The aim of this paper is to design a method for assessing the life of steam pipes for Czech power plants. The most widely-used material in Czech power plants is steel 15 128. Our findings may also be applied for international equivalents of this steel. The paper shows the classification of cavitation damage and microstructure classification status, based on the German VGB Act, with references to EPRI law in the USA. Calculations of remaining life on the basis of Russian experience are also sh...

  3. Lifetime Assessment of a Steam Pipeline

    OpenAIRE

    Jiří Janovec; Daniela Poláchová; Michal Junek

    2012-01-01

    The aim of this paper is to design a method for assessing the life of steam pipes for Czech power plants. The most widely-used material in Czech power plants is steel 15 128. Our findings may also be applied for international equivalents of this steel. The paper shows the classification of cavitation damage and microstructure classification status, based on the German VGB Act, with references to EPRI law in the USA. Calculations of remaining life on the basis of Russian experience are also sh...

  4. Starting of the steam generator of a fossil fuel power plant, using predictive control based in a neuronal model; Arranque del generador de vapor de una central termoelectrica, usando control predictivo basado en un modelo neuronal

    Energy Technology Data Exchange (ETDEWEB)

    Gallardo Dominguez, Tonatiuh

    2004-09-15

    In this thesis work it is presented the design and implementation of a simulator of total scope of a predictive controller based in the neuronal model of the temperature in two stages of the heating of the steam generator of a fossil fuel power plant. An implemented control scheme is detailed, as well as the methodology for the identification of a neuronal model utilized for the control. Finally the results of the implementation in the simulator located at the Instituto de Investigaciones Electricas (IIE) are shown to be satisfactory. This control structure is not applied directly in closed circuit, but provides the value of the control actions to a human operator. [Spanish] En este trabajo de tesis se presenta el diseno e implementacion, en un simulador de alcance total, de un controlador predictivo basado en un modelo neuronal para el control de la temperatura en dos etapas del calentamiento del generador de vapor de una central termoelectrica. Se detalla el esquema de control implementado, asi como la metodologia de identificacion de un modelo neuronal utilizado para la sintesis del control. Finalmente se muestran los resultados de la implementacion en el simulador que se encuentra en el Instituto de Investigaciones Electricas (IIE); dichos resultados fueron satisfactorios. Esta estructura de control no se aplica directamente en lazo cerrado, sino que provee el valor de las acciones de control a un operador humano.

  5. 火电厂汽水管道弹簧计算选择与安装调试一致性分析%Analysis of consistency between thermal power plant steam water pipeline spring' s calculation and installation

    Institute of Scientific and Technical Information of China (English)

    周发明; 叶小斌

    2011-01-01

    分析了目前在火电厂汽水管道应力分析中应用最广的Glif和CAESARⅡ的弹簧计算选择方法,比较了两种软件计算方法的异同点,提出应使弹簧计算选择与安装调试保持一致性,根据不同的弹簧计算选择方式采用相应的安装调试方法,以使弹性支吊架按设计正常工作。%The Glif and CAESARⅡ of spring' s calculation & choosing is analysis,which is the most widely used method in thermal power plant steam and water pipeline stress analysis. This paper deals with similarities and dissimilarities between Gift and CAESARⅡ. Depending on the method of spring' s calculating & choosing, it use the corresponding method in order to the hanger can work as it is designed.

  6. PMK-2. Experimental study on steam generator behaviour

    Energy Technology Data Exchange (ETDEWEB)

    Ezsoel, G.; Szabados, L.; Trosztel, I. [KFKI Atomic Energy Research Inst., Budabest (Hungary)

    1995-12-31

    The PMK-2 is a full pressure scaled-down model of the Paks Nuclear Power Plant, with a 1:2070 scaling ratio for the volume and power. It has a steam generator model which is a vertical section of the horizontal steam generator. The model has hot and cold collectors similarly to the steam generators of the plant. The heat transfer tubes are horizontal tubes. There are 82 rows of tubes and the elevations, as well as the heat transfer surface distribution is the same as in the plant. The elevation of the feed water supply is similar to that of the plant. To study the temperature distribution in both the primary and the secondary side several thermocouples are built in, in addition to the overall instrumentation of the loop which has again a high number of measurement channels. Paper gives a description and results of SPE-4, with special respect to the steam generator behaviour in both steady state and transient conditions. Axial distribution of coolant and feedwater temperatures are given for the primary and the secondary side of hot and cold collectors and the temperature distribution in the centre of steam generator. (orig.).

  7. Wet steam wetness measurement in a 10 MW steam turbine

    Directory of Open Access Journals (Sweden)

    Kolovratník Michal

    2014-03-01

    Full Text Available The aim of this paper is to introduce a new design of the extinction probes developed for wet steam wetness measurement in steam turbines. This new generation of small sized extinction probes was developed at CTU in Prague. A data processing technique is presented together with yielded examples of the wetness distribution along the last blade of a 10MW steam turbine. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o.

  8. Wet steam wetness measurement in a 10 MW steam turbine

    OpenAIRE

    Kolovratník Michal; Bartoš Ondřej

    2014-01-01

    The aim of this paper is to introduce a new design of the extinction probes developed for wet steam wetness measurement in steam turbines. This new generation of small sized extinction probes was developed at CTU in Prague. A data processing technique is presented together with yielded examples of the wetness distribution along the last blade of a 10MW steam turbine. The experimental measurement was done in cooperation with Doosan Škoda Power s.r.o.

  9. Economic efficiency of a gas-turbine topping for steam reheating at heating turbo-installations

    OpenAIRE

    Romashova Olga; Belyaev Leonid; Tubolev Aleksandr; Skrebatun Egor

    2017-01-01

    The article considers the ways to improve the operating efficiency of conventional combined heat power plants using gas-turbine topping scheme allowing heat utilization of flue gases for steam reheating in the waste-heat steam boiler. The calculating analysis was performed for a steam-turbine power generating unit with a turbine of the Т-110/120-130 brand name intended for various modes of operation.

  10. Economic efficiency of a gas-turbine topping for steam reheating at heating turbo-installations

    Directory of Open Access Journals (Sweden)

    Romashova Olga

    2017-01-01

    Full Text Available The article considers the ways to improve the operating efficiency of conventional combined heat power plants using gas-turbine topping scheme allowing heat utilization of flue gases for steam reheating in the waste-heat steam boiler. The calculating analysis was performed for a steam-turbine power generating unit with a turbine of the Т-110/120-130 brand name intended for various modes of operation.

  11. Actual operation and regulatory activities on steam generator replacement in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Saeki, Hitoshi [Kyushu Electric Power Co., Inc., Fukyoka (Japan)

    1997-02-01

    This paper summarizes the operating reactors in Japan, and the status of the steam generators in these plants. It reviews plans for replacement of existing steam generators, and then goes into more detail on the planning and regulatory steps which must be addressed in the process of accomplishing this maintenance. The paper also reviews the typical steps involved in the process of removal and replacement of steam generators.

  12. A detection of the coarse water droplets in steam turbines

    Directory of Open Access Journals (Sweden)

    Bartoš Ondřej

    2014-03-01

    Full Text Available The aim of this paper is to introduce a novel method for the detection of coarse water droplets in a low pressure part of steam turbines. The photogrammetry method has been applied for the measurement of coarse droplets in the low-pressure part of a steam turbine. A new probe based on this measurement technique was developed and tested in the laboratory and in a steam turbine in the Počerady power-plant. The probe was equipped with state-of-the-art instrumentation. The paper contains results from laboratory tests and the first preliminary measurements in a steam turbine. Possible applications of this method have been examined.

  13. Mandarin peel wastes pretreatment with steam explosion for bioethanol production.

    Science.gov (United States)

    Boluda-Aguilar, María; García-Vidal, Lidia; González-Castañeda, Fayiny Del Pilar; López-Gómez, Antonio

    2010-05-01

    The mandarin (Citrus reticulata L.) citrus peel wastes (MCPW) were studied for bioethanol production, obtaining also as co-products: d-limonene, galacturonic acid, and citrus pulp pellets (CPP). The steam explosion pretreatment was analysed at pilot plant level to decrease the hydrolytic enzymes requirements and to separate and recover the d-limonene. The effect of steam explosion on MCPW lignocellulosic composition was analyzed by means thermogravimetric analysis. The d-limonene contents and their influence on ethanol production have been also studied, while concentration of sugars, galacturonic acid and ethanol have been analysed to measure the saccharification and fermentation (HF and SSF) processes efficiency obtained by MCPW steam explosion pretreatment. Ethanol contents of 50-60L/1000kg raw MCPW can be obtained and CPP yields can be regulated by means the control of enzymes dose and the steam explosion pretreatment which can significantly reduce the enzymes requirements.

  14. Materials for advanced ultrasupercritical steam turbines

    Energy Technology Data Exchange (ETDEWEB)

    Purgert, Robert [Energy Industries Of Ohio Inc., Independence, OH (United States); Shingledecker, John [Energy Industries Of Ohio Inc., Independence, OH (United States); Saha, Deepak [Energy Industries Of Ohio Inc., Independence, OH (United States); Thangirala, Mani [Energy Industries Of Ohio Inc., Independence, OH (United States); Booras, George [Energy Industries Of Ohio Inc., Independence, OH (United States); Powers, John [Energy Industries Of Ohio Inc., Independence, OH (United States); Riley, Colin [Energy Industries Of Ohio Inc., Independence, OH (United States); Hendrix, Howard [Energy Industries Of Ohio Inc., Independence, OH (United States)

    2015-12-01

    The U.S. Department of Energy (DOE) and the Ohio Coal Development Office (OCDO) have sponsored a project aimed at identifying, evaluating, and qualifying the materials needed for the construction of the critical components of coal-fired power plants capable of operating at much higher efficiencies than the current generation of supercritical plants. This increased efficiency is expected to be achieved principally through the use of advanced ultrasupercritical (A-USC) steam conditions. A limiting factor in this can be the materials of construction for boilers and for steam turbines. The overall project goal is to assess/develop materials technology that will enable achieving turbine throttle steam conditions of 760°C (1400°F)/35MPa (5000 psi). This final technical report covers the research completed by the General Electric Company (GE) and Electric Power Research Institute (EPRI), with support from Oak Ridge National Laboratory (ORNL) and the National Energy Technology Laboratory (NETL) – Albany Research Center, to develop the A-USC steam turbine materials technology to meet the overall project goals. Specifically, this report summarizes the industrial scale-up and materials property database development for non-welded rotors (disc forgings), buckets (blades), bolting, castings (needed for casing and valve bodies), casting weld repair, and casting to pipe welding. Additionally, the report provides an engineering and economic assessment of an A-USC power plant without and with partial carbon capture and storage. This research project successfully demonstrated the materials technology at a sufficient scale and with corresponding materials property data to enable the design of an A-USC steam turbine. The key accomplishments included the development of a triple-melt and forged Haynes 282 disc for bolted rotor construction, long-term property development for Nimonic 105 for blading and bolting, successful scale-up of Haynes 282 and Nimonic 263 castings using

  15. Steam-frothing of milk for coffee

    DEFF Research Database (Denmark)

    Münchow, Morten; Jørgensen, Leif; Amigo Rubio, Jose Manuel

    2015-01-01

    A method for evaluation of the foaming properties of steam-frothed milk, based on image analysis (feature extraction) carried out on a video taken immediately after foam formation, was developed. The method was shown to be able to analyse steam-frothed milk made using a conventional espresso...... machine, such as commonly used by baristas. Samples of milk, processed in a commercial dairy plant, were made with varying fat (0.5%, 0.9%, 1.5%, 2.6%, 3.5%) or protein (3.0%, 3.4%. 3.8%) content and analysed using the developed method. Increased protein content was shown to cause a delay in the formation...

  16. Thermodynamic properties of superheated and supercritical steam

    Energy Technology Data Exchange (ETDEWEB)

    Malhotra, A. [Indian Inst. of Technology, New Delhi (India). Dept. of Mechanical Engineering; Panda, D.M.R. [Dadri Gas Power Station, NTPC, Gautam Buddha Nagar (India)

    2001-07-01

    An existing formulation for steam properties is due to Irvine and Liley. Their equations are convenient to program and do not require excessive computational time to produce results. The properties computed from these equations compare favourably with standard data. An additional advantage of these equations is that they follow prescribed theoretical trends by reducing to perfect-gas behaviour away from the saturation dome. However, a difficulty with these equations is that, at pressures above 10 MPa and close to the saturation dome, unacceptably large errors (above 10%) are produced. These equations are examined in the present work with a view towards enhancing their range of application through the use of additional functions. It is shown that the errors may be reduced to within 1% over the entire range of pressures (both sub-critical and super-critical pressures) required in steam-plant calculations. (author)

  17. Continuous steam hydrolysis of tulip poplar

    Energy Technology Data Exchange (ETDEWEB)

    Fieber, C.; Colcord, A.R.; Faass, S.; Muzzy, J.D.; Roberts, R.S.

    1982-08-01

    To produce ethanol from hardwood it is desirable to fractionate the hardwood in order to produce a relatively pure cellulosic pulp for dilute acid hydrolysis. An experimental investigation of continuous steam hydrolysis of tulip poplar wood chips indicates that over 90% of the lignin present can be extracted by 0.1N sodium hydroxide, resulting in a cellulose pulp containing over 90% hexosan. The study was performed using a Stake Technology, Ltd., continuous digester rated at one oven dry ton per hour of wood chips. The yields of hexosans, hexoses, xylan, xylose, lignin, furfural, acetic acid and methanol were determined as a function of residence time and steam pressure in the digester. The information provides a basis for establishing a material and energy balance for a hardwood to ethanol plant.

  18. Nonlinear H-infinity control of nuclear steam generators

    Science.gov (United States)

    Ramalho, Fernando Pinto

    Motivated by the fact that problems related to the control of steam generators are responsible for a significant amount of downtime in nuclear power plants, this thesis investigates the applicability of linear and nonlinear Hinfinity theory to the control of nuclear steam generators. A nonlinear model based on mass, energy, and momentum balances was developed for a U-tube steam generator, with the water level and steam quality at the exit of the riser considered as state variables. In this model the steam flow to the turbines and the heat flow from the primary to the secondary side are represented as disturbances affecting the system, while the feedwater flow is used to compensate for changes in the water level. The performance specifications for the feedback loop are encoded using weight functions incorporated into an augmented plant, and the control problem is formulated to minimize the effects of disturbances on the controlled variables. The solution of the optimization problem is reduced to the solution of a set of differential equations, which, in the linear case, is equivalent to the solution of Riccati equations. The linear Hinfinity controller and filter were obtained for the U-tube steam generator with and without weight functions, and simulations for a 50 s ramp transient resulting in 50% decrease in the heat and steam flows were performed over 300 s. The use of weights provided less variation in the water level, and an excellent noise rejection capability was observed. For the nonlinear Hinfinity formulation a finite-difference method was used to solve the state and costate equations numerically for optimal feedwater flow minimizing water level variations. The combined solution of the state equation in the forward direction and the costate equations in the backward direction converged in 10 iteractions. The nonlinear controller results in less variation in the water level than the corresponding linear Hinfinity controller, demonstrating the feasibility

  19. Characterisation of the micro- and nanoscale structure of new creep-resistant steels for use in advanced USC steam power plants

    Energy Technology Data Exchange (ETDEWEB)

    Zielinska-Lipiec, A.; Czyrska-Filemonowicz, A. [AGH University of Science & Technology, Krakow (Poland)

    2007-05-15

    The microstructure in the as received condition and after long-term creep exposure (up to about 57000 h at 600 and 650{sup o}C of the martensitic 9-12% chromium steels (P92, P91, E911, CB6) developed for advanced ultra supercritical coal-fired power plants has been investigated. Using analytical TEM statistical quantitative analyses were undertaken to determine the micro- and nanoscale structure parameters (dislocation density within the subgrains, the width of the martensite laths/subgrains and the particles parameters). Results of the TEM analyses reveal significant influence of a microstructure after initial heat treatment on the creep strength.

  20. Process for purifying geothermal steam

    Science.gov (United States)

    Li, C.T.

    Steam containing hydrogen sulfide is purified and sulfur recovered by passing the steam through a reactor packed with activated carbon in the presence of a stoichiometric amount of oxygen which oxidizes the hydrogen sulfide to elemental sulfur which is adsorbed on the bed. The carbon can be recycled after the sulfur has been recovered by vacuum distillation, inert gas entrainment or solvent extraction. The process is suitable for the purification of steam from geothermal sources which may also contain other noncondensable gases.

  1. Wet steam treatment with oxygen

    Energy Technology Data Exchange (ETDEWEB)

    Ruehle, W.; Enkler, G. [EnBW Kraftwerke AG, Kernkraftwerk Philippsburg (Germany)

    1999-07-01

    After many years of excellent results using high all volatile treatment (HAVT) for operation of the secondary system of a PWR, flow assisted corrosion in the heating pipes of the intermediate steam reheaters has been experienced. Oxygen addition into the heating steam before the reheater is expected to improve the protective oxide layers formation. The reaction of oxygen with the alkalizing steam ingredients is described. (orig.)

  2. Regenerative superheated steam turbine cycles

    Science.gov (United States)

    Fuller, L. C.; Stovall, T. K.

    1980-01-01

    PRESTO computer program was developed to analyze performance of wide range of steam turbine cycles with special attention given to regenerative superheated steam turbine cycles. It can be used to model standard turbine cycles, including such features as process steam extraction, induction and feedwater heating by external sources, peaking, and high back pressure. Expansion line efficiencies, exhaust loss, leakages, mechanical losses, and generator losses are used to calculate cycle heat rate and generator output. Program provides power engineer with flexible aid for design and analysis of steam turbine systems.

  3. Effect of liquid waste discharges from steam generating facilities

    Energy Technology Data Exchange (ETDEWEB)

    McGuire, H.E. Jr.

    1977-09-01

    This report contains a summary of the effects of liquid waste discharges from steam electric generating facilities on the environment. Also included is a simplified model for use in approximately determining the effects of these discharges. Four basic fuels are used in steam electric power plants: three fossil fuels--coal, natural gas, and oil; and uranium--presently the basic fuel of nuclear power. Coal and uranium are expected to be the major fuels in future years. The following power plant effluents are considered: heat, chlorine, copper, total dissolved solids, suspended solids, pH, oil and grease, iron, zinc, chrome, phosphorus, and trace radionuclides.

  4. Dynamic computer simulation of the Fort St. Vrain steam turbines

    Energy Technology Data Exchange (ETDEWEB)

    Conklin, J.C.

    1983-01-01

    A computer simulation is described for the dynamic response of the Fort St. Vrain nuclear reactor regenerative intermediate- and low-pressure steam turbines. The fundamental computer-modeling assumptions for the turbines and feedwater heaters are developed. A turbine heat balance specifying steam and feedwater conditions at a given generator load and the volumes of the feedwater heaters are all that are necessary as descriptive input parameters. Actual plant data for a generator load reduction from 100 to 50% power (which occurred as part of a plant transient on November 9, 1981) are compared with computer-generated predictions, with reasonably good agreement.

  5. Physical and statistical models for steam generator clogging diagnosis

    CERN Document Server

    Girard, Sylvain

    2014-01-01

    Clogging of steam generators in nuclear power plants is a highly sensitive issue in terms of performance and safety and this book proposes a completely novel methodology for diagnosing this phenomenon. It demonstrates real-life industrial applications of this approach to French steam generators and applies the approach to operational data gathered from French nuclear power plants. The book presents a detailed review of in situ diagnosis techniques and assesses existing methodologies for clogging diagnosis, whilst examining their limitations. It also addresses numerical modelling of the dynamic

  6. Steam process supply optimization for Arcelormittal Tubarao consumers; Otimizacao do sistema de fornecimento de vapor de processo para a usina (AMT)

    Energy Technology Data Exchange (ETDEWEB)

    Loss, Gecimar; Oliveira, Heron Domingues de; Silva, Jose Geraldo Lessa; Beccalli, Marcelo; Calente, Paulo Sergio Boni; Monteiro, Sergio Anderson [Companhia Siderurgica de Tubarao ArcelorMittal, Serra, ES (Brazil)

    2010-07-01

    The ArcelorMittal Tubarao Energy Production area is compounded by three units: Air Separation Units, Thermal Power Plants and Thermal Recovery Power Plants. The Thermo Power Plants are co-generated units responsible to generate electrical, mechanical (Blast Furnace blower) energy and also provide Steam to complement the facility internal consumption mainly provided by CDQ plant (CDQ - Coke Dry Quenching). Since RH2 (steel treatment process) start up, the steam consumption increased and the Thermal Power Plant contribution raised to attend this new demand. Solutions were needed to guarantee the steam supply by the Power Plant even in low steam header stoppages for maintenance, since the lack of steam caused by shortage in Power Plant steam supply resulting in steel production diminution in this new scenario. (author)

  7. Modern geothermal power: GeoPP with geothermal steam turbines

    Science.gov (United States)

    Tomarov, G. V.; Shipkov, A. A.

    2017-03-01

    The first part of the review presents information on the scale and specific features of geothermal energy development in various countries. The classification of geothermal power plant (GeoPP) process flow diagrams by a phase state of the primary heat source (a geothermal fluid), thermodynamic cycle, and applicable turbines is proposed. Features of geothermal plants using methods of flashing and steam separation in the process loop and a flowsheet and thermodynamic process of a geothermal fluid heat-to-power conversion in a GeoPP of the most widespread type using a double-flash separation are considered. It is shown that, for combined cycle power units, the specific power-to-consumption geothermal fluid ratio is 20-25% higher than that for traditional single-loop GeoPP. Information about basic chemical components and their concentration range for geothermal fluids of various formations around the world is presented. Three historic stages of improving geothermal energy technologies are determined, such as development of high-temperature geothermal resources (dry, superheated steam) and application of a two-phase wet-steam geothermal fluid in GeoPP power units with one or two expansion pressures and development of binary cycle GeoPPs. A current trend of more active use of binary power plants in GeoPP technological processes is noted. Design features of GeoPP's steam turbines and steam separating devices, determined by the use of low-potential geothermal saturated steam as a working medium, which is characterized by corrosion aggressiveness and a tendency to form deposits, are considered. Most promising Russian geothermal energy projects are determined. A list of today's most advanced geothermal turbine performance technologies is presented. By an example of a 25 MW steam turbine design, made by JSC Kaluga Turbine Works, advantages of the internal moisture separation with a special turbine-separator stage are shown.

  8. Steam refining as an alternative to steam explosion.

    Science.gov (United States)

    Schütt, Fokko; Westereng, Bjørge; Horn, Svein J; Puls, Jürgen; Saake, Bodo

    2012-05-01

    In steam pretreatment the defibration is usually achieved by an explosion at the end of the treatment, but can also be carried out in a subsequent refiner step. A steam explosion and a steam refining unit were compared by using the same raw material and pretreatment conditions, i.e. temperature and time. Smaller particle size was needed for the steam explosion unit to obtain homogenous slurries without considerable amounts of solid chips. A higher amount of volatiles could be condensed from the vapour phase after steam refining. The results from enzymatic hydrolysis showed no significant differences. It could be shown that, beside the chemical changes in the cell wall, the decrease of the particle size is the decisive factor to enhance the enzymatic accessibility while the explosion effect is not required.

  9. Transient analysis with high percentages steam generator tube plugging of Angra 1 nuclear power plant; Analise de transientes com altos percentuais de tamponamento dos tubos dos geradores de vapor de Angra 1

    Energy Technology Data Exchange (ETDEWEB)

    Lima, Marcio Poubel; Martins Junior, Laercio Lucena; Vanni, Enio Antonio; Machado, Marcio Dornellas; Moreira, Francisco Jose [ELETRONUCLEAR, Rio de Janeiro, RJ (Brazil); Alvim, Antonio Carlos M. [Universidade Federal, Rio de Janeiro, RJ (Brazil). Coordenacao dos Programas de Pos-graduacao de Engenharia. Programa de Engenharia Nuclear

    1999-11-01

    The present work is part of several analyses under development in ELETRONUCLEAR/ COPPE-UFRJ to evaluate impacts on licensing bases and operating conditions of an increase in steam generator tube plugging for Angra 1 NPP. Total loss of reactor coolant flow uncontrolled boron dilution transients were initially analysed. The final results indicated that were no impacts on FSAR established margins, in case of 24% steam generator tube plugging. (author) 3 refs., 4 figs., 4 tabs.

  10. Losses estimation in transonic wet steam flow through linear blade cascade

    Science.gov (United States)

    Dykas, Sławomir; Majkut, Mirosław; Strozik, Michał; Smołka, Krystian

    2015-04-01

    Experimental investigations of non-equilibrium spontaneous condensation in transonic steam flow were carried out in linear blade cascade. The linear cascade consists of the stator blades of the last stage of low pressure steam turbine. The applied experimental test section is a part of a small scale steam power plant located at Silesian University of Technology in Gliwice. The steam parameters at the test section inlet correspond to the real conditions in low pressure part of 200MWe steam turbine. The losses in the cascade were estimated using measured static pressure and temperature behind the cascade and the total parameters at inlet. The static pressure measurements on the blade surface as well as the Schlieren pictures were used to assess the flow field in linear cascade of steam turbine stator blades.

  11. Radioactive demonstration of final mineralized waste forms for Hanford waste treatment plant secondary waste (WTP-SW) by fluidized bed steam reforming (FBSR) using the bench scale reformer platform

    Energy Technology Data Exchange (ETDEWEB)

    Crawford, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Burket, P. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Cozzi, A. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Daniel, G. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Jantzen, C. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL); Missimer, D. [Savannah River Site (SRS), Aiken, SC (United States). Savannah River National Lab. (SRNL)

    2014-08-01

    The U.S. Department of Energy’s Office of River Protection (ORP) is responsible for the retrieval, treatment, immobilization, and disposal of Hanford’s tank waste. Currently there are approximately 56 million gallons of highly radioactive mixed wastes awaiting treatment. A key aspect of the River Protection Project (RPP) cleanup mission is to construct and operate the Waste Treatment and Immobilization Plant (WTP). The WTP will separate the tank waste into high-level and low-activity waste (LAW) fractions, both of which will subsequently be vitrified. The projected throughput capacity of the WTP LAW Vitrification Facility is insufficient to complete the RPP mission in the time frame required by the Hanford Federal Facility Agreement and Consent Order, also known as the Tri-Party Agreement (TPA), i.e. December 31, 2047. Therefore, Supplemental Treatment is required both to meet the TPA treatment requirements as well as to more cost effectively complete the tank waste treatment mission. In addition, the WTP LAW vitrification facility off-gas condensate known as WTP Secondary Waste (WTP-SW) will be generated and enriched in volatile components such as 137Cs, 129I, 99Tc, Cl, F, and SO4 that volatilize at the vitrification temperature of 1150°C in the absence of a continuous cold cap (that could minimize volatilization). The current waste disposal path for the WTP-SW is to process it through the Effluent Treatment Facility (ETF). Fluidized Bed Steam Reforming (FBSR) is being considered for immobilization of the ETF concentrate that would be generated by processing the WTP-SW. The focus of this current report is the WTP-SW.

  12. Steam generator tube integrity program

    Energy Technology Data Exchange (ETDEWEB)

    Dierks, D.R.; Shack, W.J. [Argonne National Laboratory, IL (United States); Muscara, J.

    1996-03-01

    A new research program on steam generator tubing degradation is being sponsored by the U.S. Nuclear Regulatory Commission (NRC) at Argonne National Laboratory. This program is intended to support a performance-based steam generator tube integrity rule. Critical areas addressed by the program include evaluation of the processes used for the in-service inspection of steam generator tubes and recommendations for improving the reliability and accuracy of inspections; validation and improvement of correlations for evaluating integrity and leakage of degraded steam generator tubes, and validation and improvement of correlations and models for predicting degradation in steam generator tubes as aging occurs. The studies will focus on mill-annealed Alloy 600 tubing, however, tests will also be performed on replacement materials such as thermally-treated Alloy 600 or 690. An overview of the technical work planned for the program is given.

  13. Reliability of steam generator tubing

    Energy Technology Data Exchange (ETDEWEB)

    Kadokami, E. [Mitsubishi Heavy Industries Ltd., Hyogo-ku (Japan)

    1997-02-01

    The author presents results on studies made of the reliability of steam generator (SG) tubing. The basis for this work is that in Japan the issue of defects in SG tubing is addressed by the approach that any detected defect should be repaired, either by plugging the tube or sleeving it. However, this leaves open the issue that there is a detection limit in practice, and what is the effect of nondetectable cracks on the performance of tubing. These studies were commissioned to look at the safety issues involved in degraded SG tubing. The program has looked at a number of different issues. First was an assessment of the penetration and opening behavior of tube flaws due to internal pressure in the tubing. They have studied: penetration behavior of the tube flaws; primary water leakage from through-wall flaws; opening behavior of through-wall flaws. In addition they have looked at the question of the reliability of tubing with flaws during normal plant operation. Also there have been studies done on the consequences of tube rupture accidents on the integrity of neighboring tubes.

  14. Duplex tube steam reformer development program

    Energy Technology Data Exchange (ETDEWEB)

    Lewe, C K; Nieto, J M; Papadopoulos, A

    1978-09-01

    Work done in partial fulfillment of Task 7 of the Duplex Steam Reformer Development Program is described. The DSR concept acts as a double barrier between a process heat high temperature reactor plant (PNP) and a closed loop chemical heat pipe (CHP) for the long distance transport of chemical energy to a remote industrial user. The current state of the DSR design is described as well as related systems and equipment. The PNP concept presented is based upon work currently underway in the Federal Republic of Germany.

  15. Boxberg - a new benchmark for high efficiency steam turbines

    Energy Technology Data Exchange (ETDEWEB)

    Hoffstadt, U.; Klauke, U.; Hinz, H. [Siemens Power Generation (Germany)

    2001-07-01

    One of the primary tasks associated with the development of modern power plant facilities is to improve the economy of operation, while at the same time reducing environmental pollution. In addition to investigations focused on supercritical steam conditions, Siemens Power generation has made enormous efforts to improve the overall efficiency by decreasing the steam flow energy losses of each steam turbine component: optimization of the admission and exhaust geometries; fully three-dimensional blading profiles; reduction of the seal-steam losses; high reliability, availability and safety of operation; optimization of the efficiency/cost-relations. As a result of these efforts the 907 MW power plant Boxberg was handed over to the customer Vereinigte Energiewerke AG recently. With a thermal gross-efficiency of 48,65% the steam turbine represents a milestone for lignite-fired cogeneration units in the history of modern turbine technology. In conjunction with the presentation of the special turbine features and its optimised fluid dynamic components, the results of assembly, commissioning and acceptance testing will be a key issue in the proposed paper. 14 overheads/slides.

  16. Sustaining the Landscape: A Method for Comparing Current and Desired Future Conditions of Forest Ecosystems in the North Cumberland Plateau and Mountains

    Energy Technology Data Exchange (ETDEWEB)

    Druckenbrod, D.L.

    2004-12-22

    This project initiates an integrated-landscape conservation approach within the Northern Cumberlands Project Area in Tennessee and Kentucky. The mixed mesophytic forests within the Cumberland Plateau and Mountains are among the most diverse in North America; however, these forests have been impacted by and remain threatened from changes in land use across this landscape. The integrated-landscape conservation approach presented in this report outlines a sequence of six conservation steps. This report considers the first three of these steps in two, successive stages. Stage 1 compares desired future conditions (DFCs) and current prevailing conditions (CPCs) at the landscape-scale utilizing remote sensing imagery, remnant forests, and descriptions of historical forest types within the Cumberland Plateau. Subsequently, Stage 2 compares DFCs and CPCs for at-risk forest types identified in Stage 1 utilizing structural, compositional, or functional attributes from USFS Forest Inventory and Analysis data. Ecological indicators will be developed from each stage that express the gaps between these two realizations of the landscape. The results from these first three steps will directly contribute to the final three steps of the integrated-landscape conservation approach by providing guidance for the generation of new conservation strategies in the Northern Cumberland Plateau and Mountains.

  17. Evaluation on mechanical and corrosion properties of steam generator tubing materials

    Energy Technology Data Exchange (ETDEWEB)

    Kim, In Sup; Lee, Byong Whi; Lee, Sang Kyu; Lee, Young Ho; Kim, Jun Whan; Lee, Ju Seok; Kwon, Hyuk Sang; Kim, Su Jung [Korea Advanced Institute of Science and Technology, Taejon (Korea, Republic of)

    1998-06-15

    Steam generator is one of the major components of nuclear reactor pressure boundary. It's main function os transferring heat which generated in the reactor to turbine generator through steam generator tube. In these days, steam generator tubing materials of operating plant are used Inconel 600 alloys. But according to the operation time, there are many degradation phenomena which included mechanical damage due to flow induced vibration and corrosion damage due to PWSCC, IGA/SCC and pitting etc. Recently Inconel 690 alloys are selected as new and replacement steam generator tubes for domestic nuclear power plant. But there are few study about mechanical and corrosion properties of Inconel 600 and 690. The objectives of this study is to evaluate and compare mechanical and corrosion propertied of steam generator tube materials.

  18. Steam generators regulatory practices and issues in Spain

    Energy Technology Data Exchange (ETDEWEB)

    Mendoza, C.; Castelao, C.; Ruiz-Colino, J.; Figueras, J.M. [CSN, Madrid (Spain)

    1997-02-01

    This paper presents the actual status of Spanish Steam Generator tubes, actions developed by PWR plant owners and submitted to CSN, and regulatory activities related to tube degradation mechanisms analysis; NDT tube inspection techniques; tube, tubesheet and TSPs integrity studies; tube plugging/repair criteria; preventive and corrective measures including whole SGs replacement; tube leak measurement methods and other operational aspects.

  19. coustic Leak Detection Based on Wavelet Packet and Genetic Algorithm for LM FBR Steam Generators

    Institute of Scientific and Technical Information of China (English)

    2011-01-01

    Steam generator is one kind of key equipments in liquid metal fast breeder reactors (LM FBR) whose reliability will influence the safety of nuclear power plant. We can see that SG is the highest risky equipment from the running experience

  20. Characteristics of U-tube assembly design for CANDU 6 type steam generators

    Energy Technology Data Exchange (ETDEWEB)

    Park, Jun Su; Jeong, Seung Ha [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1996-06-01

    Since the first operation of nuclear steam generator early 1960s, its performance requirements have been met but the steam generator problems have been met but the steam generator problems have been major cause of reducing the operational reliability, plant safety and availability. U-tube assembly of steam generator forms the primary system pressure boundary of the plant and have experienced several types of tube degradation problems. Tube failure and leakage resulting from the degradation will cause radioactive contamination of secondary system by the primary coolant, and this may lead to unplanned plant outages and costly repair operations such as tube plugging or steam generator replacement. For the case of steam generators for heavy water reactors, e.g. Wolsong 2, 3, and 4 NPP, a high cost of heavy water will be imposed additionally. During the plant operation, steam generator tubes can potentially be subject to adverse environmental conditions which will cause damages to U-tube assembly. Types of the damage depend upon the combined effects of design factors, materials and chemical environment of steam generator, and they are the pure water stress corrosion cracking, intergranular attack, pitting, wastage, denting, fretting and fatigue, etc. In this report, a comprehensive review of major design factors of recirculating steam generators has been performed against the potential tube damages. Then the design characteristics of CANDU-type Wolsong steam generator were investigated in detail, including tube material, thermalhydraulic aspects, tube-to-tubesheet joint, tube supports, water chemistry and sludge management. 9 tabs., 18 figs., 38 refs. (Author) .new.

  1. General purpose steam table library :

    Energy Technology Data Exchange (ETDEWEB)

    Carpenter, John H.; Belcourt, Kenneth Noel; Nourgaliev, Robert

    2013-08-01

    Completion of the CASL L3 milestone THM.CFD.P7.04 provides a general purpose tabular interpolation library for material properties to support, in particular, standardized models for steam properties. The software consists of three parts, implementations of analytic steam models, a code to generate tables from those models, and an interpolation package to interface the tables to CFD codes such as Hydra-TH. Verification of the standard model is maintained through the entire train of routines. The performance of interpolation package exceeds that of freely available analytic implementation of the steam properties by over an order of magnitude.

  2. STEAM DALAM PEMBUATAN PAKAN UNTUK KOMODITAS AKUAKULTUR

    OpenAIRE

    Sukarman Sukarman

    2010-01-01

    Kualitas fisik pakan (pelet) untuk hewan akuakultur sangat penting, karena akan dimasukkan ke dalam air dan diharapkan tidak banyak mencemari lingkungan. Salah satu faktor yang berpengaruh dalam menjaga kualitas fisik pakan adalah penambahan dan pengaturan steam pada saat proses pembuatan pelet. Steam adalah aliran gas yang dihasilkan oleh air pada saat mendidih. Steam dibagi menjadi 3 jenis yaitu steam basah, saturated steam, dan superheated steam. Steam yang digunakan dalam proses pembuatan...

  3. Health and safety impact of steam generator tube degradation

    Energy Technology Data Exchange (ETDEWEB)

    Marston T. [PLG, Inc., Newport Beach, CA (United States)

    1997-02-01

    In this paper the author addresses the problems inherent in evaluating the safety of steam generators with respect to tube rupture as part of a probabilistic safety analysis (PSA) of a reactor plant. He reviews the history of PSA as applied to reactors, and then looks at tube rupture histories as a start toward establishing event frequencies. He considers tube ruptures from the aspect of being an initiating event to being a conditional event to some other event, and then the question of performance of the steam generator in the face of a severe accident in the reactor.

  4. Modelling studies of horizontal steam generator PGV-1000 with Cathare

    Energy Technology Data Exchange (ETDEWEB)

    Karppinen, I. [VTT Energy, Espoo (Finland)

    1995-12-31

    To perform thermal-hydraulic studies applied to nuclear power plants equipped with VVER, a program of qualification and assessment of the CATHARE computer code is in progress at the Institute of Protection and Nuclear Safety (IPSN). In this paper studies of modelling horizontal steam generator of VVER-1000 with the CATHARE computer code are presented. Steady state results are compared with measured data from the fifth unit of Novovoronezh nuclear power plant. (orig.). 10 refs.

  5. Economics of scale in the production of steam with solar thermal-fossil boiler hybrid systems

    Science.gov (United States)

    Hansen, F. R.; Lindner, D. L.; Vitko, J., Jr.

    1983-03-01

    Levelized energy costs for steam plants in the size range 15 MM Btu/h to 400 MM Btu/h were estimated for steam produced by several different technologies, including stand alone oil and coal burning plants and solar central receiver fossil boiler hybrid plants. Models for the costs of plant subsystems used in these calculations are presented. Designs of the solar fossil hybrids examined were optimized for solar fraction and amount of thermal storage used by simulation of plant operation. The resulting levelized energy costs and their sensitivity to various modelling parameters are discussed.

  6. Spatial and temporal assessment of back-barrier erosion on Cumberland Island National Seashore, Georgia, 2011–2013

    Science.gov (United States)

    Calhoun, Daniel L.; Riley, Jeffrey W.

    2016-07-15

    Much research has been conducted to better understand erosion and accretion processes for the seaward zones of coastal barrier islands; however, at Cumberland Island National Seashore, Georgia, the greater management concern is the effect that erosion is having on the resources of the island’s western shoreline, or the back barrier. Catastrophic slumping and regular rates of erosion greater than 1 meter per year threaten important habitat, historical and pre-historical resources, and modern infrastructure on the island. Prior research has helped National Park Service (NPS) staff identify the most severe and vulnerable areas, but in order to develop effective management actions, information is needed on what forces and conditions cause erosion. To this end, the U.S. Geological Survey, in cooperation with the NPS, conducted two longitudinal surveys, one each at the beginning and end of the approximately year-long monitoring period from late 2011 to early 2013, along five selected segments of the back barrier of the Cumberland Island National Seashore. Monitoring stations were constructed at four of these locations that had previously been identified as erosional hotspots. The magnitude of erosion at each location was quantified to determine the relative influence of causative agents. Results indicate that erosion is, in general, highly variable within and among these segments of the Cumberland Island National Seashore’s back barrier. Observed erosion ranged from a maximum of 2.5 meters of bluff-line retreat to some areas that exhibited no net erosion over the 1-year study period. In terms of timing of erosion, three of the four sites were primarily affected by punctuated erosional events that were coincident with above-average high tides and elevated wind speeds. The fourth site exhibited steady, low-magnitude retreat throughout the study period. While it is difficult to precisely subscribe certain amounts of erosion to specific agents, this study provides

  7. Condenser Optimization in Steam Power Plant

    Institute of Scientific and Technical Information of China (English)

    Sukru Bekdemir; Recep Ozturk; Zehra Yumurtac

    2003-01-01

    In this paper the effects of the condenser design parameters (such as turbine inlet condition, turbine power and condenser pressure) on heat transfer area, cooling water flow-rate, condenser cost and specific energy generation cost are studied for surface type condenser.The results are given in the text and also shown as diagrams.

  8. Research of laser cleaning technology for steam generator tubing

    Science.gov (United States)

    Hou, Suixa; Luo, Jijun; Xu, Jun; Yuan, Bo

    2010-10-01

    Surface cleaning based on the laser-induced breakdown of gas and subsequent shock wave generation can remove small particles from solid surfaces. Accordingly, several studies in steam generator tubes of nuclear power plants were performed to expand the cleaning capability of the process. In this work, experimental apparatus of laser cleaning was designed in order to clean heat tubes in steam generator. The laser cleaning process is monitored by analyzing acoustic emission signal experimentally. Experiments demonstrate that laser cleaning can remove smaller particles from the surface of steam generator tubes better than other cleaning process. It has advantages in saving on much manpower and material resource, and it is a good cleaning method for heat tubes, which can be real-time monitoring in laser cleaning process of heat tubes by AE signal. As a green cleaning process, laser cleaning technology in equipment maintenance will be a good prospect.

  9. Modelling horizontal steam generator with ATHLET. Verification of different nodalization schemes and implementation of verified constitutive equations

    Energy Technology Data Exchange (ETDEWEB)

    Beliaev, J.; Trunov, N.; Tschekin, I. [OKB Gidropress (Russian Federation); Luther, W. [GRS Garching (Germany); Spolitak, S. [RNC-KI (Russian Federation)

    1995-12-31

    Currently the ATHLET code is widely applied for modelling of several Power Plants of WWER type with horizontal steam generators. A main drawback of all these applications is the insufficient verification of the models for the steam generator. This paper presents the nodalization schemes for the secondary side of the steam generator, the results of stationary calculations, and preliminary comparisons to experimental data. The consideration of circulation in the water inventory of the secondary side is proved to be necessary. (orig.). 3 refs.

  10. Steam reforming of ethanol

    DEFF Research Database (Denmark)

    Trane-Restrup, Rasmus; Dahl, Søren; Jensen, Anker Degn

    2013-01-01

    Steam reforming (SR) of oxygenated species like bio-oil or ethanol can be used to produce hydrogen or synthesis gas from renewable resources. However, deactivation due to carbon deposition is a major challenge for these processes. In this study, different strategies to minimize carbon deposition...... on Ni-based catalysts during SR of ethanol were investigated in a flow reactor. Four different supports for Ni were tested and Ce0.6Zr0.4O2 showed the highest activity, but also suffered from severe carbon deposition at 600 °C or below. Operation at 600 °C or above were needed for full conversion...... 400 ppm of the carbon in the feed at approx. 600 °C. The different promoters did not influence the product distribution to any significant extent. Selective poisoning with small amounts of K2SO4 on Ni–CeO2/MgAl2O4 at 600 °C decreased carbon deposition from 900 to 200 ppm of the carbon in the feed...

  11. Hydrogen-based power generation from bioethanol steam reforming

    Science.gov (United States)

    Tasnadi-Asztalos, Zs.; Cormos, C. C.; Agachi, P. S.

    2015-12-01

    This paper is evaluating two power generation concepts based on hydrogen produced from bioethanol steam reforming at industrial scale without and with carbon capture. The power generation from bioethanol conversion is based on two important steps: hydrogen production from bioethanol catalytic steam reforming and electricity generation using a hydrogen-fuelled gas turbine. As carbon capture method to be assessed in hydrogen-based power generation from bioethanol steam reforming, the gas-liquid absorption using methyl-di-ethanol-amine (MDEA) was used. Bioethanol is a renewable energy carrier mainly produced from biomass fermentation. Steam reforming of bioethanol (SRE) provides a promising method for hydrogen and power production from renewable resources. SRE is performed at high temperatures (e.g. 800-900°C) to reduce the reforming by-products (e.g. ethane, ethene). The power generation from hydrogen was done with M701G2 gas turbine (334 MW net power output). Hydrogen was obtained through catalytic steam reforming of bioethanol without and with carbon capture. For the evaluated plant concepts the following key performance indicators were assessed: fuel consumption, gross and net power outputs, net electrical efficiency, ancillary consumptions, carbon capture rate, specific CO2 emission etc. As the results show, the power generation based on bioethanol conversion has high energy efficiency and low carbon footprint.

  12. Hydrogen-based power generation from bioethanol steam reforming

    Energy Technology Data Exchange (ETDEWEB)

    Tasnadi-Asztalos, Zs., E-mail: tazsolt@chem.ubbcluj.ro; Cormos, C. C., E-mail: cormos@chem.ubbcluj.ro; Agachi, P. S. [Babes-Bolyai University, Faculty of Chemistry and Chemical Engineering, 11 Arany Janos, Postal code: 400028, Cluj-Napoca (Romania)

    2015-12-23

    This paper is evaluating two power generation concepts based on hydrogen produced from bioethanol steam reforming at industrial scale without and with carbon capture. The power generation from bioethanol conversion is based on two important steps: hydrogen production from bioethanol catalytic steam reforming and electricity generation using a hydrogen-fuelled gas turbine. As carbon capture method to be assessed in hydrogen-based power generation from bioethanol steam reforming, the gas-liquid absorption using methyl-di-ethanol-amine (MDEA) was used. Bioethanol is a renewable energy carrier mainly produced from biomass fermentation. Steam reforming of bioethanol (SRE) provides a promising method for hydrogen and power production from renewable resources. SRE is performed at high temperatures (e.g. 800-900°C) to reduce the reforming by-products (e.g. ethane, ethene). The power generation from hydrogen was done with M701G2 gas turbine (334 MW net power output). Hydrogen was obtained through catalytic steam reforming of bioethanol without and with carbon capture. For the evaluated plant concepts the following key performance indicators were assessed: fuel consumption, gross and net power outputs, net electrical efficiency, ancillary consumptions, carbon capture rate, specific CO{sub 2} emission etc. As the results show, the power generation based on bioethanol conversion has high energy efficiency and low carbon footprint.

  13. Hydrogen production from biomass over steam gasification

    Energy Technology Data Exchange (ETDEWEB)

    Rauch, R.; Potetz, A.; Hofbauer, H. [Vienna Univ. of Technology (Austria). Inst. of Chemical Engineering; Weber, G. [Bioenergy 2020+, Guessing (Austria)

    2010-12-30

    Renewable hydrogen is one option for a clean energy carrier in the future. There were several research programs in the past, to produce hydrogen on a renewable basis by electrolysis, direct conversion of water or by gasification of biomass. None of these options were developed to a stage, that they could be used on a commercial basis. At the moment almost all hydrogen is produced from fossil fuels and one main consumer of hydrogen are refineries. So a good option to demonstrate the production of renewable hydrogen and bring it later into the market is over refineries. The most economic option to produce renewable hydrogen at the moment is over gasification of biomass. In Austria an indirect gasification system was developed and is demonstrated in Guessing, Austria. The biomass CHP Guessing uses the allothermal steam dual fluidised bed gasifier and produces a high grade product gas, which is used at the moment for the CHP in a gas engine. As there is no nitrogen in the product gas and high hydrogen content, this gas can be also used as synthesis gas or for production of hydrogen. The main aim of this paper is to present the experimental and simulation work to convert biomass into renewable hydrogen. The product gas of the indirect gasification system is mainly hydrogen, carbon monoxide, carbon dioxide and methane. Within the ERA-Net project ''OptiBtLGas'' the reforming of methane and the CO-shift reaction was investigated to convert all hydrocarbons and carbon monoxide to hydrogen. On basis of the experimental results the mass- and energy balances of a commercial 100 MW fuel input plant was done. Here 3 different cases of complexity of the overall plant were simulated. The first case was without reforming and CO-shift, only by hydrogen separation. The second case was by including steam - reforming and afterwards separation of hydrogen. The third case includes hydrocarbon reforming, CO-shift and hydrogen separation. In all cases the off-gases (CO

  14. ChemCam investigation of the John Klein and Cumberland drill holes and tailings, Gale crater, Mars

    Science.gov (United States)

    Jackson, R. S.; Wiens, R. C.; Vaniman, D. T.; Beegle, L.; Gasnault, O.; Newsom, H. E.; Maurice, S.; Meslin, P.-Y.; Clegg, S.; Cousin, A.; Schröder, S.; Williams, J. M.

    2016-10-01

    The ChemCam instrument on the Mars Science Laboratory rover analyzed the rock surface, drill hole walls, tailings, and unprocessed and sieved dump piles to investigate chemical variations with depth in the first two martian drill holes and possible fractionation or segregation effects of the drilling and sample processing. The drill sites are both in Sheepbed Mudstone, the lowest exposed member of the Yellowknife Bay formation. Yellowknife Bay is composed of detrital basaltic materials in addition to clay minerals and an amorphous component. The drill tailings are a mixture of basaltic sediments and diagenetic material like calcium sulfate veins, while the shots on the drill site surface and walls of the drill holes are closer to those pure end members. The sediment dumped from the sample acquisition, processing, and handling subsystem is of similar composition to the tailings; however, due to the specifics of the drilling process the tailings and dump piles come from different depths within the hole. This allows the ChemCam instrument to analyze samples representing the bulk composition from different depths. On the pre-drill surfaces, the Cumberland site has a greater amount of CaO and evidence for calcium sulfate veins, than the John Klein site. However, John Klein has a greater amount of calcium sulfate veins below the surface, as seen in mapping, drill hole wall analysis, and observations in the drill tailings and dump pile. In addition, the Cumberland site does not have any evidence of variations in bulk composition with depth down the drill hole, while the John Klein site has evidence for a greater amount of CaO (calcium sulfates) in the top portion of the hole compared to the middle section of the hole, where the drill sample was collected.

  15. Steam generator design for solar towers using solar salt as heat transfer fluid

    Science.gov (United States)

    González-Gómez, Pedro Ángel; Petrakopoulou, Fontina; Briongos, Javier Villa; Santana, Domingo

    2017-06-01

    Since the operation of a concentrating solar power plant depends on the intermittent character of solar energy, the steam generator is subject to daily start-ups, stops and load variations. Faster start-up and load changes increase the plant flexibility and the daily energy production. However, it involves high thermal stresses on thick-walled components. Continuous operational conditions may eventually lead to a material failure. For these reasons, it is important to evaluate the transient behavior of the proposed designs in order to assure the reliability. The aim of this work is to analyze different steam generator designs for solar power tower plants using molten salt as heat transfer fluid. A conceptual steam generator design is proposed and associated heat transfer areas and steam drum size are calculated. Then, dynamic models for the main parts of the steam generator are developed to represent its transient performance. A temperature change rate that ensures safe hot start-up conditions is studied for the molten salt. The thermal stress evolution on the steam drum is calculated as key component of the steam generator.

  16. On the Sourcing of Steam and Electricity for Carbon Capture Retrofits.

    Science.gov (United States)

    Supekar, Sarang D; Skerlos, Steven J

    2017-10-02

    This paper compares different steam and electricity sources for carbon capture and sequestration (CCS) retrofits of pulverized coal (PC) and natural gas combined cycle (NGCC) power plants. Analytical expressions for the thermal efficiency of these power plants are derived under 16 different CCS retrofit scenarios for the purpose of illustrating their environmental and economic characteristics. The scenarios emerge from combinations of steam and electricity sources, fuel used in each source, steam generation equipment and process details, and the extent of CO2 capture. Comparing these scenarios reveals distinct trade-offs between thermal efficiency, net power output, levelized cost, profit, and net CO2 reduction. Despite causing the highest loss in useful power output, bleeding steam and extracting electric power from the main power plant to meet the CCS plant's electricity and steam demand maximizes plant efficiency and profit while minimizing emissions and levelized cost when wholesale electricity prices are below 4.5 and 5.2 US¢/kWh for PC-CCS and NGCC-CCS plants, respectively. At prices higher than these, higher profits for operating CCS retrofits can be obtained by meeting a 100% of the CCS plant's electric power demand using an auxiliary natural gas turbine-based combined heat and power plant.

  17. Kinetics of Zr-alloy cladding oxidation in the mixture of air and steam at high temperatures

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Kyung Tae; Park, Kwang Heon; Park, Joo Young [Kyunghee University, Yongin (Korea, Republic of)

    2012-05-15

    In Fukushima Daiichi Nuclear Power Plant accident, No.4 plant was exploded by hydrogen explosion. There was a strong speculation about the possibility of the reaction between the overheated fuels and the steam-air mixture in the storage pool. Later, it turned out to be due to the hydrogen leaked from No.3 plant. However, the reaction of the hot fuels with the steam-air mixture became an important issue. There have been a lot of data accumulated about Zr-alloy interaction with steam. However, Zr-alloy interactions with air and steam-air mixtures have not been studied relatively much. In this study, we measured the oxidation kinetics of Zry-4 and Zirlo claddings in air, and steam-air mixtures, and analyzed the kinetics

  18. Dynamic behavior of superheated steam and ways of control

    Institute of Scientific and Technical Information of China (English)

    Xu LI

    2008-01-01

    A simple way of calculating the dynamic behavior of a superheater is presented. A comparison of the measured data with the calculated result verifies the accuracy of this simple method. It is the first time that a phase compensation for real roots, i.e., the twin lead/lag loop which is facile for engineering applications, is used in superheated steam temperature control. Numerous simu-lation results show that both the response time lapse and maximal dynamic deviation are greatly reduced. Moreover, a formula to calculate the setting parameters is presented, together with a practical example of its engineering application in superheated steam temperature control with single-stage attemperation in a power plant boiler. This method can remarkably improve the control performance of superheated steam temperature and makes it possible for one stage attemperation to be sufficient for the superheater of power plant boilers, thus simplifying the superheater system and reducing investment. Because the control performance is remarkably raised, the set values of the steam temperature control system can be raised above rated values and also the operational economy, without impairing the operation safety.

  19. Recent Life Assessment Technology for Existing Steam Turbines

    Science.gov (United States)

    Saito, Kiyoshi; Sakuma, Akira; Fukuda, Masataka

    A large and growing portion of electricity is produced by aging thermal power plants. Although excellent, high quality materials such as CrMoV steel and 12% Cr steel, etc. are used for the steam turbines, various forms of metallurgical degradation, due to creep and fatigue, etc. affect the parts and components during long-term operation at high temperature. Extending the life of steam turbines and ensuring high reliability requires life assessment technology, scheduled repairing, conversion, modification and upgrading of components in order to provide a stable power supply. As the high temperature parts and components of aged steam turbines are mainly metallurgically damaged by creep, fatigue and the interaction of both, life assessment combined with analytical and nondestructive methods is essential for realizing strategic plant life extension. We have developed a life assessment technology that takes material degradation into consideration, and have applied the procedure to more than 650 units and 2500 components since 1983. A rotor bore replication device was developed in 1989 for the purpose of nondestructive observation of creep voids and supporting the validity of life prediction results. This paper describes the technical features and applied experience of recent life assessment technology for existing high temperature steam turbines.

  20. Steam generator tube inspection in Japan

    Energy Technology Data Exchange (ETDEWEB)

    Fukui, Shigetaka [Japan Power Engineering and Inspection Corp., Tokyo (Japan)

    1997-02-01

    Steam generator tube inspection was first carried out in 1971 at Mihama Unit-1 that is first PWR plant in Japan, when the plant was brought into the first annual inspection. At that time, inspection was made on sampling basis, and only bobbin coil probe was used. After experiencing various kinds of tube degradations, inspection method was changed from sampling to all number of tubes, and various kinds of probes were used to get higher detectability of flaw. At present, it is required that all the tubes shall be inspected in their full length at each annual inspection using standard bobbin coil probe, and some special probes for certain plants that have susceptibility of occurrence of flaw. Sleeve repaired portion is included in this inspection. As a result of analyses of eddy current testing data, all indications that have been evaluated to be 20% wall thickness or deeper shall be repaired by either plugging or sleeving, where flaw morphology is to be a wastage or wear. Other types of flaw such as IGA/SCC are not allowed to be left inservice when those indications are detected. These inspections are performed according to inspection procedures that are approved by regulatory authority. Actual inspections are witnessed by the Japan Power engineering and inspection corporation (JAPEIC)`s inspectors during data acquisition and analysis, and they issue inspection report to authority for review and approval. It is achieved high safety performance of steam generator through this method of inspections, however. some tube leakage problems were experienced in the past. To prevent recurrence of such events, government is conducting development and verification test program for new eddy current testing technology.

  1. Dynamics of mineral N, water-soluble carbon and potential nitrification in band-steamed arable soil

    DEFF Research Database (Denmark)

    Elsgaard, Lars

    2010-01-01

    Steaming of narrow soil bands prior to sowing is a new technique that reduces the need for intra-row weeding in herbicide-free row crops. However, the steam treatment may eliminate both weed seeds and non-target soil organisms, thereby affecting the nutrient cycling in the soil. This study tested...... not statistically significant. Mechanical effects of band-steaming were negligible. The observed ammonium surplus could be of agronomic benefit and should be evaluated in integrated studies of the effects of band-steaming on crop growth and plant N uptake...

  2. Physics of steam generators and visit of Saint-Marcel plant; La physique des generateurs de vapeur et la visite de l'Usine de Saint-Marcel

    Energy Technology Data Exchange (ETDEWEB)

    Gillet, N.; Gloaguen, C.; Holcblat, A. [FRAMATOME ANP, 92 - Paris La Defence (France); Borsoi, L. [CEA Saclay (SEMT/DYN), 91 - Gif sur yvette (France); Adobes, A.; David, F. [Electricite de France (EDF/RD), 75 - Paris (France); Greiner, E. [Electricite de France (EDF CIPN-CM), 13 - Marseille (France); Pascal-Ribot, S. [CEA Cadarache, 13 - Saint Paul lez Durance (France); Gauchet, J.P. [Electricite de France (EDF/UTO/GVD), 93 - Noisy le Grand (France); Mercier, L. [Electricite de France (EDF/CAPE/GMC), 93 - Saint enis (France); Leomy, F. [FRAMATOME ANP, 71 - Chalon (France)

    2004-07-01

    This document gathers the transparencies presented at the 6. technical session of the French nuclear energy society (SFEN) in June 2004. The main topic was the physics of steam generators: 1 - description (G. Paudroux, J.Y. Guena, M. Petit); 2 - thermo-hydraulics (A. Holcblat, F. David, S. Pascal-Ribot); 3 - mechanics (N. Gillet, L. Borsoi, A. Adobes); 4 - monitoring and maintenance means (J.P. Gauchet, L. Mercier, F. Leomy); 5 - replacement (C. Gloaguen, E. Greiner). (J.S.)

  3. Steam vacuum cleaning. Innovative technology summary report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-05-01

    The US Department of Energy (DOE) continually seeks safer and more cost-effective remediation technologies for use in the decontamination and decommissioning (D and D) of nuclear facilities. The baseline technology currently used for washing debris is a high-pressure water cleaning (HPWC) system. The system used at the FEMP is the Hotsy{reg_sign} Model 550B HPWC. Although the HPWC technology has functioned satisfactorily, improvements are being sought in areas related to reduced liquid waste volume, increased productivity, increased washing effectiveness, and decreased airborne contamination. An innovative technology that offers potential improvements in these areas is a steam vacuum cleaning (SVC) system that integrates high-pressure steam cleaning with a vacuum recovery sub-system that simultaneously collects dislodged contaminants thereby reducing airborne contamination. The SVC system selected for demonstration at the FEMP was the Kelly{trademark} Decontamination System shown. This report provides comparative performance and cost analyses between the Hotsy HPWC system and the Kelly Decontamination System. Both technologies were demonstrated at the FEMP site located at Fernald, Ohio from July 29, 1996 through August 15, 1996. The demonstrations were conducted at the FEMP Plant 1 as part of the LSTD project sponsored by the Deactivation and Decommissioning Focus Area (DDFA) of the US DOE`s Office of Science and Technology.

  4. Fault diagnosis in the steam generator of a thermoelectric power plant using Petri networks; Diagnostico de fallas en el generador de vapor de una termoelectrica usando redes de Petri

    Energy Technology Data Exchange (ETDEWEB)

    Suarez Cerda, Dionisio A; Sanchez Lopez, Alfredo [Instituto de Investigaciones Electricas, Cuernavaca, Morelos (Mexico); Martinez Prieto, Jose E; Garcia Beltran, Carlos D. [Centro Nacional de Investigacion y Desarrollo Tecnologico, Cuernavaca, Morelos (Mexico)

    2007-07-01

    With time, all physical systems show modifications in the dynamics of its operation. This can be attributed to different causes, for example, wear by friction, deterioration by overheating or natural aging, among others. These changes evolve gradually, until getting to become faults related to the reliability, availability, efficiency, safety and continuity of the operation, which seriously affect the performance indexes of the system. In this article a scheme of fault diagnosis is shown, applied to the steam generator of a thermoelectric power unit, based on techniques of modeling of dynamic systems by means of Petri networks. Against other methods, the scheme offers greater easiness for its implementation, rapidity of adaptation before changes of operation zone and good robustness. A way to reduce the effect of faults in a production system consists of two steps. The first one is to diagnose the fault as soon as it occurs and subsequently put into practice remedial actions. The concept of fault diagnosis is related to the first stage and encompasses the detection, as well as the location of this one. That is to say, besides determining that a fault is present, it is known in what component it has happened. In base to the former, it is clear that a diagnosis system requires supervising the variables that characterize the behavior of the faults, in order to detect them at the moment in which they occur and informing it to the operator. With this information, the operator will be able to realize the necessary remedial actions so that the plant continues operating as long as possible. [Spanish] Con el tiempo, todo sistema fisico manifiesta modificaciones en la dinamica de su funcionamiento. Esto puede atribuirse a diferentes causas, como por ejemplo, desgaste por friccion, deterioro por sobrecalentamiento o envejecimiento natural, entre otras. Estos cambios evolucionan gradualmente, hasta llegar a convertirse en fallas relacionadas con la confiabilidad

  5. Steam Digest 2001: Office of Industrial Technologies

    Energy Technology Data Exchange (ETDEWEB)

    None, None

    2002-01-01

    Steam Digest 2001 chronicles Best Practices Program's contributions to the industrial trade press for 2001, and presents articles that cover technical, financial and managerial aspects of steam optimization.

  6. Continuous steam hydrolysis of tulip poplar

    Energy Technology Data Exchange (ETDEWEB)

    Fieber, C.A.; Roberts, R.S.; Faass, G.S.; Muzzy, J.D.; Colcord, A.R.; Bery, M.K.

    1982-01-01

    The continuous hydrolysis of poplar chips by steam at 300-350 psi resulted in the separation of hemicellulose (I) cellulose and lignin components. The I fraction was readily depolymerised by steam to acetic acid, furfural, methanol, and xylose.

  7. Steam pretreatment for coal liquefaction

    Science.gov (United States)

    Ivanenko, Olga

    The objectives of this work are to test the application of steam pretreatment to direct coal liquefaction, to investigate the reaction of model compounds with water, and to explore the use of zeolites in these processes. Previous work demonstrated the effectiveness of steam pretreatment in a subsequent flash pyrolysis. Apparently, subcritical steam ruptures nearly all of the ether cross links, leaving a partially depolymerized structure. It was postulated that very rapid heating of the pretreated coal to liquefaction conditions would be required to preserve the effects of such treatment. Accordingly, a method was adopted in which coal slurry is injected into a hot autoclave containing solvent. Since oxygen is capable of destroying the pretreatment effect, precautions were taken for its rigorous exclusion. Tests were conducted with Illinois No. 6 coal steam treated at 340sp°C, 750 psia for 15 minutes. Both raw and pretreated samples were liquified in deoxygenated tetralin at high severity (400sp°C, 30 min.) and low severity (a: 350sp°C, 30 min., and b: 385sp°C, 15 min.) conditions under 1500 psia hydrogen. Substantial improvement in liquid product quality was obtained and the need for rapid heating and oxygen exclusion demonstrated. Under low severity conditions, the oil yield was more than doubled, going from 12.5 to 29 wt%. Also chemistry of the pretreatment process was studied using aromatic ethers as model compounds. alpha-Benzylnaphthyl ether (alpha-BNE), alpha-naphthylmethyl phenyl (alpha-NMPE), and 9-phenoxyphenanthrene were exposed to steam and inert gas at pretreatment conditions and in some cases to liquid water at 315sp°C. alpha-BNE and alpha-NMPE showed little difference in conversion in inert gas and in steam. Hence, these compounds are poor models for coal in steam pretreatment. Thermally stable 9-phenoxyphenanthrene, however, was completely converted in one hour by liquid water at 315sp°C. At pretreatment conditions mostly rearranged starting

  8. Quadratic controller syntheses for the steam generator water level

    Energy Technology Data Exchange (ETDEWEB)

    Arzelier, D.; Daafouz, J.; Bernussou, J.; Garcia, G

    1998-06-01

    The steam generator water level, (SGWL), control problem in the pressurized water reactor of a nuclear power plant is considered from robust control techniques point of view. The plant is a time-varying system with a non minimum phase behavior and an unstable open-loop response. The time-varying nature of the plant due to change in operating power is taken into account by including slowly time-varying uncertainty in the model. A linear Time-Invariant, (LTI) guaranteed cost quadratic stabilizing controller is designed in order to address some of the particular issues arising for such a control problem. (author) 17 refs.

  9. THERMODYNAMICAL ANALYSIS OF HIGH-PRESSURE FEED WATER HEATER IN STEAM PROPULSION SYSTEM DURING EXPLOITATION

    Directory of Open Access Journals (Sweden)

    Igor Poljak

    2017-01-01

    Full Text Available Nowadays diesel engines prevail as ship propulsion. However, steam propulsion is still primary drive for LNG carriers. In the presented paper high-pressure feed water heater was analyzed, as one of the essential components in LNG carrier steam propulsion system. Measurements of all operating parameters (fluid streams at the analyzed heat exchanger inlets and outlets were performed. Change of the operating parameters was measured at different steam system loads, not at full load as usual. Through these measurements was enabled the insight into the behaviour of the heat exchanger operating parameters during the whole exploitation. The numerical analysis was performed, based on the measured data. The changes in energy and exergy efficiency of the heat exchanger were analyzed. Energetic and exergetic power inputs and outputs were also calculated, which enabled an insight into the change of energetic and exergetic power losses of the heat exchanger at different steam system loads. Change in energetic and exergetic power losses and operating parameters, which have the strongest influence on the high-pressure feed water heater losses, were described. Analyzed heat exchanger was compared with similar heat exchangers in the base loaded conventional steam power plants. From the conducted analysis, it is concluded that the adjustment and control modes of these high-pressure heat exchangers are equal, regardless of whether they were mounted in the base loaded conventional steam power plants or marine steam systems, while their operating parameters and behaviour patterns differ greatly.

  10. STEAM DALAM PEMBUATAN PAKAN UNTUK KOMODITAS AKUAKULTUR

    Directory of Open Access Journals (Sweden)

    Sukarman Sukarman

    2010-12-01

    Full Text Available Kualitas fisik pakan (pelet untuk hewan akuakultur sangat penting, karena akan dimasukkan ke dalam air dan diharapkan tidak banyak mencemari lingkungan. Salah satu faktor yang berpengaruh dalam menjaga kualitas fisik pakan adalah penambahan dan pengaturan steam pada saat proses pembuatan pelet. Steam adalah aliran gas yang dihasilkan oleh air pada saat mendidih. Steam dibagi menjadi 3 jenis yaitu steam basah, saturated steam, dan superheated steam. Steam yang digunakan dalam proses pembuatan pelet adalah saturated steam. Pengaruh penambahan steam pada kualitas pelet bisa mencapai 20%. Penambahan steam dengan jumlah dan kualitas yang tepat akan menghasilkan pelet berkualitas. Sedangkan jika pengaturan dan penambahannya tidak tepat, maka kualitas fisik pelet akan rendah dan kemungkinan bisa merusak kandungan nutrisi seperti vitamin dan protein. Penambahan steam yang benar bisa dilakukan di dalam kondisioner dengan mengatur retention time, sudut kemiringan paddle conditioner, kecepatan putaran bearing dan menjaga kualitas steam dari mesin boiler sampai dengan kondisioner.

  11. Parametric study for horizontal steam generator modelling

    Energy Technology Data Exchange (ETDEWEB)

    Ovtcharova, I. [Energoproekt, Sofia (Bulgaria)

    1995-12-31

    In the presentation some of the calculated results of horizontal steam generator PGV - 440 modelling with RELAP5/Mod3 are described. Two nodalization schemes have been used with different components in the steam dome. A study of parameters variation on the steam generator work and calculated results is made in cases with separator and branch.

  12. Studies of the steam generator degraded tubes behavior on BRUTUS test loop

    Energy Technology Data Exchange (ETDEWEB)

    Chedeau, C.; Rassineux, B. [EDF/DER/MTC, Moret Sur Loing (France); Flesch, B. [EDF/EPN/DMAINT, Paris (France)] [and others

    1997-04-01

    Studies for the evaluation of steam generator tube bundle cracks in PWR power plants are described. Global tests of crack leak rates and numerical calculations of crack opening area are discussed in some detail. A brief overview of thermohydraulic studies and the development of a mechanical probabilistic design code is also given. The COMPROMIS computer code was used in the studies to quantify the influence of in-service inspections and maintenance work on the risk of a steam generator tube rupture.

  13. Modeling of an once through helical coil steam generator of a superheated cycle for sizing analysis

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Yeon Sik; Sim, Yoon Sub; Kim, Eui Kwang [Korea Atomic Energy Research Institute, Taejon (Korea, Republic of)

    1997-12-31

    A thermal sizing code, named as HSGSA (Helical coil Steam Generator Sizing Analyzer), for a sodium heated helical coil steam generator is developed for KALIMER (Korea Advanced LIquid MEtal Reactor) design. The theoretical modeling of the shell and tube sides is described and relevant correlations are presented. For assessment of HSGSA, a reference plant design case is compared to the calculational outputs from HSGSA simulation. 9 refs., 6 figs. (Author)

  14. Maintenance of Power Steam Turbine

    OpenAIRE

    Kapelovich, Boris; Khmelnik, Solomon; Kapelovich, David; Benenson, Evgeny

    2008-01-01

    The diagnostics system of the power steam turbine is offered. It can be executed also in the form of telediagnostic system. The system is presented on a site http://turbo.mic34.com/ System engineering can is ordered to authors.

  15. Steam-water relative permeability

    Energy Technology Data Exchange (ETDEWEB)

    Ambusso, W.; Satik, C.; Home, R.N. [Stanford Univ., CA (United States)

    1997-12-31

    A set of relative permeability relations for simultaneous flow of steam and water in porous media have been measured in steady state experiments conducted under the conditions that eliminate most errors associated with saturation and pressure measurements. These relations show that the relative permeabilities for steam-water flow in porous media vary approximately linearly with saturation. This departure from the nitrogen/water behavior indicates that there are fundamental differences between steam/water and nitrogen/water flows. The saturations in these experiments were measured by using a high resolution X-ray computer tomography (CT) scanner. In addition the pressure gradients were obtained from the measurements of liquid phase pressure over the portions with flat saturation profiles. These two aspects constitute a major improvement in the experimental method compared to those used in the past. Comparison of the saturation profiles measured by the X-ray CT scanner during the experiments shows a good agreement with those predicted by numerical simulations. To obtain results that are applicable to general flow of steam and water in porous media similar experiments will be conducted at higher temperature and with porous rocks of different wetting characteristics and porosity distribution.

  16. Generalised pole-placement control of steam turbine speed

    Energy Technology Data Exchange (ETDEWEB)

    Fernandez-del-Busto, R. [ITESM, Cuernavaca (Mexico). Div. de Ingenieria y Ciencias; Munoz, J. [ITESM, Xochimilco (Mexico). Div. de Ingenieria y Ciencias

    1996-12-31

    An application of a pole-placement self-tuning predictive control algorithm is developed to regulate speed of a power plant steam turbine model. Two types of system representation (CARMA and CARIMA) are used to test the control algorithm. Simulation results show that when using a CARMA model better results are produced. Two further comparisons are made when using a PI controller and a generalised predictive controller. (author)

  17. Steam generator corrosion 2007; Dampferzeugerkorrosion 2007

    Energy Technology Data Exchange (ETDEWEB)

    Born, M. (ed.)

    2007-07-01

    Between 8th and 9th November, 2007, SAXONIA Standortentwicklungs- und -verwertungsgesellschaft GmbH (Freiberg, Federal Republic of Germany) performed the 3rd Freiberger discussion conference ''Fireside boiler corrosion''. The topics of the lectures are: (a) Steam generator corrosion - an infinite history (Franz W. Alvert); (b) CFD computations for thermal waste treatment plants - a contribution for the damage recognition and remedy (Klaus Goerner, Thomas Klasen); (c) Experiences with the use of corrosion probes (Siegfried R. Horn, Ferdinand Haider, Barbara Waldmann, Ragnar Warnecke); (d) Use of additives for the limitation of the high temperature chlorine corrosion as an option apart from other measures to the corrosion protection (Wolfgang Spiegel); (e) Current research results and aims of research with respect to chlorine corrosion (Ragnar Warnecke); (f) Systematics of the corrosion phenomena - notes for the enterprise and corrosion protection (Thomas Herzog, Wolfgang Spiegel, Werner Schmidl); (g) Corrosion protection by cladding in steam generators of waste incinerators (Joerg Metschke); (h) Corrosion protection and wear protection by means of thermal spraying in steam generators (Dietmar Bendix); (i) Review of thick film nickelized components as an effective protection against high-temperature corrosion (Johann-Wilhelm Ansey); (j) Fireproof materials for waste incinerators - characteristics and profile of requirement (Johannes Imle); (k) Service life-relevant aspects of fireproof linings in the thermal recycling of waste (Till Osthoevener and Wolfgang Kollenberg); (l) Alternatives to the fireproof material in the heating space (Heino Sinn); (m) Cladding: Inconal 625 contra 686 - Fundamentals / applications in boiler construction and plant construction (Wolfgang Hoffmeister); (n) Thin films as efficient corrosion barriers - thermal spray coating in waste incinerators and biomass firing (Ruediger W. Schuelein, Steffen Hoehne, Friedrich

  18. Technoeconomic study on steam explosion application in biomass processing.

    Science.gov (United States)

    Zimbardi, Francesco; Ricci, Esmeralda; Braccio, Giacobbe

    2002-01-01

    This work is based on the data collected during trials of a continuous steam explosion (SE) plant, with a treatment capacity of about 350 kg/h, including the biomass fractionation section. The energy and water consumption, equipment cost, and manpower needed to run this plant have been used as the base case for a techno-economic evaluation of productive plants. Three processing plant configurations have been considered: (I) SE pretreatment only; (II) SE followed by the hemicellulose extraction; (III) SE followed by the sequential hemicellulose and lignin extractions. The biomass treatment cost has been evaluated as a function of the plant scale. For each configuration, variable and fixed cost breakdown has been detailed in the case of a 50,000 t/y plant.

  19. Analysis of Steam Line Break for the Development of KNGR EOG

    Energy Technology Data Exchange (ETDEWEB)

    Jeong, H.Y.; Lee, S.R. [Korea Electric Power Research Institute, Taejon (Korea)

    2000-02-01

    The steam line break accidents are analyzed for the development of KNGR emergency operation guidelines (EOG). Realistic plant initial conditions and assumptions are applied because it is important to evaluate the best-estimate plant behavior for the development of EOG. The steam line break analysis is required to prepare the Excess Steam Demand Event (ESDE) of the Optimal Recovery Guidelines (ORG). Five cases of SLBFP, SLBFPLOP, SLBZP, SLPFPNSI, and ZP2RCP are analysed considering the power level, plant conditions, and possible operator actions. The results show that the accident can be mitigated safely and the requirements described in the guidelines are satisfied when the plant is controlled following the provided procedures . (author). 3 refs., 70 figs.

  20. Fault diagnosis in the steam turbo-generator of a Combined Cycle Power Plant; Diagnostico de fallas en el turbogenerador a vapor de una central de generacion de ciclo combinado

    Energy Technology Data Exchange (ETDEWEB)

    Flores Abad, Angel

    2006-12-15

    Due to the physical nature of its components, technological processes are vulnerable to faults. These faults affect the accurate behavior of the system, causing a performance reduction, even great economical losses and in the worst case environmental and human disasters. The opportune detection of the presence of faults helps to take corrective actions and as a consequence to reduce the potential damage that faults cause. To achieve the fault detection task, technological processes have supervisory systems to monitor the process variables and provide an alarm when a variable reached a given threshold. This method has the drawback that a single fault could cause many system alarms, which difficult the fault isolation. In addition it is based on hardware redundancy; it means the use of repeated devices to do the same work. Combined cycle power plants (CCPP) are large scale systems with a high degree of fault susceptibility. Due to strict conditions in which they operate and the great number of elements they contain, including sensors and actuators. Nowadays this kind of power plants tends to dominate the electric generation market by means of fossil fuels, because they are the most efficient, profitable, with flexible operation and with less environmental impact. In the CCPP, the steam turbine (ST) is a fundamental component, since it represents the process gain, in the way that it allows the generation of additional electric energy by taking advantage of the exhaust gases of the gas turbines. In case of the ST fails, the global efficiency of the process is reduced even in a 40%. In this work a model based fault diagnosis system was developed, according to the FDI (Fault Detection and Isolation) methodology of the control theory, with the capability of detecting and isolating faults in the sensors and actuators of the ST of a CCPP. The developed system is based on the analytical redundancy which allows optimizing the hardware redundancy and getting a reduction of the

  1. Solid-phase extraction-gas chromatography and solid-phase extraction-gas chromatography-mass spectrometry determination of corrosion inhibiting long-chain primary alkyl amines in chemical treatment of boiler water in water-steam systems of power plants.

    Science.gov (United States)

    Kusch, Peter; Knupp, Gerd; Hergarten, Marcus; Kozupa, Marian; Majchrzak, Maria

    2006-04-28

    Gas chromatography with simultaneous flame-ionization detection (FID) and a nitrogen-phosphorus detection (NPD) as well as gas chromatography-mass spectrometry (GC/MS) has been used to characterize long-chain primary alkyl amines after derivatization with trifluoroacetic anhydride (TFAA). Electron impact ionization- (EI) and negative chemical ionization (NCI) mass spectra of trifluoroacetylated derivatives of the identified tert-octadecylamines are presented for the first time. The corrosion inhibiting alkyl amines were applied in a water-steam circuit of energy systems in the power industry. Solid-phase extraction (SPE) with octadecyl bonded silica (C18) sorbents followed by gas chromatography were used for quantification of the investigated tert-octadecylamines in boiler water, superheated steam and condensate samples from the power plant. The estimated values were: 89 microg l(-1)(n = 5, RSD = 7.8%), 45 microg l(-1) (n = 5, RSD = 5.4%) and 37 microg l(-1)(n = 5, RSD = 2.3%), respectively.

  2. Steam treatment of volcanic cinder media for the eradication of Rotylenchulus reniformis

    Science.gov (United States)

    Volcanic cinder has historically been free of plant parasitic nematodes. The recent contamination of cinder media by Rotylenchulus reniformis in Hawaii necessitates growers to steam sterilize cinder used in potted plant exports. Certification requirements call for the center of the media to reach ...

  3. Steam treatment of forest ground vegetation to improve tree seedling establishment and growth

    Energy Technology Data Exchange (ETDEWEB)

    Norberg, Gisela [Swedish Univ. of Agricultural Sciences, Umeaa (Sweden). Dept. of Forest Vegetation Ecology

    2000-07-01

    Mechanical soil scarification is the commonly used site preparation technique in Sweden today and there is a need for alternative site preparation methods to fulfil some environmental goals in Swedish forestry. Thermal vegetation control could be an alternative method that reduces the competing forest ground vegetation with minimal disturbance to the mineral soil and ground floor. The aim with this work has been to investigate if it is possible to control forest ground vegetation by steam treatment as an alternative site preparation method before planting or seeding. Studies were conducted on four sites, each representing main Swedish forest vegetation types, i.e. the ground vegetation was dominated by crowberry (Empetrum hermaphroditum Hagerup), bilberry (Vaccinium myrtillus L.), heather (Calluna vulgaris (L.) Hull) and wavy hair grass (Deschampsia flexuosa (L.) Trin). Steam generally controlled recolonization of vegetation on all investigated sites for a longer time than soil scarification. Especially in controlling grass vegetation steam treatment was much more effective than soil scarification. The establishment and growth of seeded Scots pine seedlings also improved after vegetation control by steam treatment compared to that in intact vegetation. For all sites, both steam treatment and soil scarification improved seedling height growth compared to seedlings planted in intact vegetation. In the bilberry and heather dominated sites seedling growth in steam treated plots was even better than for seedlings planted in mechanical soil scarified plots. Further, key biological soil processes such as microbial activity and mycorrhizal colonisation were not negatively affected by steam treatment. The conclusion made from these studies is that steam treatment has the potential to be used as an alternative site preparation method especially on sites dominated by ericaceous vegetation. However, the method requires some further technical development before it may be used

  4. Understanding the Factors Influencing Nonindustrial Private Forest Landowner Interest in Supplying Ecosystem Services in Cumberland Plateau, Tennessee

    Directory of Open Access Journals (Sweden)

    Nana Tian

    2015-11-01

    Full Text Available Private forests provide a range of ecosystem services for society including provisioning, regulating, cultural, and supporting services. Sustaining the supply of such services depends on the interest of nonindustrial private forest (NIPF landowners in managing their forests for such services. Assessing factors that influence NIPF landowner intentions would be useful in identifying potential suppliers of ecosystem services and in designing and implementing outreach and education programs to elevate the interests of less interested landowners. Using data collected from a mail survey of NIPF landowners on the Cumberland Plateau of Tennessee, this study examined how landowner interest in supplying ecosystem services was influenced by socio-demographic characteristics, economic and market factors, land management objectives, and ownership motivations. To that end, a multivariate logistic regression model was employed to analyze the supply of three types of ecosystem services: carbon storage (regulating service, water quality (provisioning service, and aesthetics (cultural service. Results revealed that landowner interest in managing forests for ecosystem services were significantly related to socio-demographic factors, management and ownership characteristics, and availability of financial incentives. These findings will improve the understanding of the market segment of landowners as related to ecosystem services. The findings may facilitate the development of market protocols and outreach programs that promote payments for ecosystem services in Tennessee and elsewhere.

  5. Ground-water data for the Suck Creek area of Walden Ridge, southern Cumberland Plateau, Marion County, Tennessee

    Science.gov (United States)

    Hanchar, D.W.

    1995-01-01

    An investigation was made of the ground-water resources of the Suck Creek area, Marion County, Tennessee, 1990-91. Suck Creek is located on the Walden Ridge section of the Cumberland Plateau, and is about 16 miles northwest of Chattanooga. Eight wells were drilled into bedrock of Pennsylvania age. Drilling sites were chosen at or near fracture traces. Yields of the eight wells ranged from less than 1 to as much as 80 gallons of water per minute. Three wells had yields of 50 gallons per minute or more; two of these had estimated yields of 75 to 80 gallons per minute. These three wells produced water from a well- developed fracture within the Sewanee Conglomerate. Specific capacities for these three wells were 1.1, 1.3, 2.2 gallons per minute per foot of drawdown. Samples of water from six test wells and three domestic wells were analyzed for major inorganic constituents, nurients, major metals, trace elements, and bacteria. In addition, water samples from two of the test wells were analyzed for volatile organic compounds and scanned for the presence of semi-volatile organic compounds. Iron exceeded 300 micrograms per liter in five of the nine samples, and manganese exceeded 50 micrograms per liter in seven of the nine water samples. Toluene, a volatile organic compound, was detected in a concentration slightly above the reporting level; no other volatile organic compounds were detected.

  6. A young clade repeating an old pattern: diversity in Nothonotus darters (Teleostei: Percidae) endemic to the Cumberland River.

    Science.gov (United States)

    Keck, Benjamin P; Near, Thomas J

    2010-11-01

    Hypotheses of diversification in eastern North American freshwater fishes have focused primarily on allopatric distributions of species between disjunct highland areas and major river systems. However, these hypotheses do not fully explain the rich diversity of species within highland regions and river systems. Relatively old diversification events at small geographic scales have been observed in the Barcheek Darter subclade that occurs in the Cumberland River drainage (CRD) in Kentucky and Tennessee, United States of America, but it is unknown if this pattern is consistent in other darter subclades. We explored phylogeographic diversity in two species of Nothonotus darters, N. microlepidus and N. sanguifluus, endemic to the CRD to compare phylogenetic patterns between Barcheek Darters and species of Nothonotus. We collected sequence data for a mitochondrial gene (cytb) and three nuclear genes (MLL, S7 and RAG1) from 19 N. microlepidus and 35 N. sanguifluus specimens. Gene trees were estimated using maximum likelihood and Bayesian methods, and a 'species tree' was inferred using a Bayesian method. These trees indicate that species diversity in Nothonotus is underestimated. Five distinct lineages were evident, despite retained ancestral polymorphism and unsampled extirpated populations. Comparison of chronograms for Barcheek Darters and Nothonotus revealed that microendemism resulting from species diversification at small geographic scales in the CRD is a consistent pattern in both old and young darter subclades. Our analyses reveal that geographic isolating mechanisms that result in similar phylogeographic patterns in the CRD are persistent through long expanses of evolutionary time.

  7. Evaluation of the coal reserves in the Whitwell Shale in the Southern Cumberland Plateau in Tennessee. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Wilson, R.L.; Warren, G.F.; Milici, R.C.

    1979-05-01

    The Southern Tennessee Coal Field comprises some 14,000 square miles of the Cumberland Plateau Physiographic Province and includes all or parts of 11 counties. The coal measures belong to the Lower Pennsylvanian System. The largest coal potential lies with the Richland and Sewanee seams, which are contained in the Whitwell Shale. The methods of obtaining coal reserve data in this report are adaptations of those used by the Tennessee Division of Geology, US Bureau of Mines, and US Geological Survey. This study differs from previous coal reserve estimates in that emphasis is placed on recoverable underground reserves as well as strippable reserves. Conservative premises were used throughout this study so that the resulting reserve figures may be considered as the minimum known recoverable coal reserves. Therefore, the total known recoverable reserves of coal in the Whitwell Shale in Southern Tennessee as of January 1, 1979, are 377,385,000 tons based on the above criteria considered with recovery factors of 50% for underground mining and 80% for strip mining. The Sewanee seam contains the largest part of these reserves totaling 312,665,000 tons. The largest reserves in any Southern Tennessee county are in Sequatchie County with 86,580,000 tons. The reserves in this area are ample for the future, and are much larger than previously estimated.

  8. COMPUTATIONAL FLUID DYNAMIC ANALYSIS OF INTERMEDIATE PRESSURE STEAM TURBINE

    OpenAIRE

    C RAJESH BABU

    2013-01-01

    a steam prime mover with rotary motion of the driving element, or rotor, and continuous operation. It converts the thermal energy of steam into mechanical work. The steam flow proceeds through directing devices and impinges on curved blades mounted along the periphery of the rotor. By exerting a force on the blades, the steam flow causes the rotor to rotate. Unlike the reciprocating steam engine, the steam turbine makes use of the kinetic rather than the potential energy of steam. The perform...

  9. Inhibition of DNA polymerase λ and associated inflammatory activities of extracts from steamed germinated soybeans.

    Science.gov (United States)

    Mizushina, Yoshiyuki; Kuriyama, Isoko; Yoshida, Hiromi

    2014-04-01

    During the screening of selective DNA polymerase (pol) inhibitors from more than 50 plant food materials, we found that the extract from steamed germinated soybeans (Glycine max L.) inhibited human pol λ activity. Among the three processed soybean samples tested (boiled soybeans, steamed soybeans, and steamed germinated soybeans), both the hot water extract and organic solvent extract from the steamed germinated soybeans had the strongest pol λ inhibition. We previously isolated two glucosyl compounds, a cerebroside (glucosyl ceramide, AS-1-4, compound ) and a steroidal glycoside (eleutheroside A, compound ), from dried soybean, and these compounds were prevalent in the extracts of the steamed germinated soybeans as pol inhibitors. The hot water and organic solvent extracts of the steamed germinated soybeans and compounds and selectively inhibited the activity of eukaryotic pol λ in vitro but did not influence the activities of other eukaryotic pols, including those from the A-family (pol γ), B-family (pols α, δ, and ε), and Y-family (pols η, ι, and κ), and also showed no effect on the activity of pol β, which is of the same family (X) as pol λ. The tendency for in vitro pol λ inhibition by these extracts and compounds showed a positive correlation with the in vivo suppression of TPA (12-O-tetradecanoylphorbol-13-acetate)-induced inflammation in mouse ear. These results suggest that steamed germinated soybeans, especially the glucosyl compound components, may be useful for their anti-inflammatory properties.

  10. Strategies and actions for the mitigation of the phenomenon DENTING in the tube sheet (TTS Denting) steam generators of the NPP Asco Denting at the top of the SG tube sheet (TTS tube denting) has recently been experienced in new and replacement SGs at several plants; Estrategias y acciones para la mitigacion del fenomeno DENTING en la placa tubular de generadores de vapor (TTS DENTING) de la Central Nuclear de Asco

    Energy Technology Data Exchange (ETDEWEB)

    Espanol Villar, J.

    2013-07-01

    It is highly likely that the accumulation of sludge (deposits) on the tube sheet is clearly associated with the denting occurrence. More specifically, it is commonly believed that an aggressive crevice environment formed within the deposits or in the shallow tight tube sheet to tube crevice below the deposits is at the origin of the denting (tube deformation), and, when present, the consequent stress corrosion cracking (SCC). There are described a set of strategies that have been followed since the emergence of the TTS denting phenomenon on Steam Generator of the Nuclear Power Plants Asco I and II, influenced by the presence of hard sludge in the tube plate of Steam Generators, their results and the evolution of the phenomenon in relation to the various measures taken.

  11. 离子色谱测试技术在火电厂水汽化学监督中的应用与进展%The Application. and Progress of lon Chromatography Usedfor Pure-High Water and Steam Monitoring in Thermal Power Plant

    Institute of Scientific and Technical Information of China (English)

    曹顺安; 谢学军; 许金莹; 钟金昌

    2001-01-01

    综述了离子色谱测试技术在火电厂高纯水和蒸汽品质分析监测中的应用和进展,展示了离子色谱这一现代微量湿化学分析技术在火电厂水汽化学监督中的显著特点,离子色谱方法必将成为电厂水汽化学品质监测的主导方法之一。%In this paper, the application and progress,remarkable characteristics,special fascination and great potentiality of ion chromatography technique used for monitoring high-pure water and steam in thermal power plant have been summarized.

  12. Study on 300MW Unit Steam Turbine Shift Seal Renovation in Shanghai Steam Turbine Factory%上汽300 MW机组汽封改造初探

    Institute of Scientific and Technical Information of China (English)

    孙海荣; 葛圣杰

    2015-01-01

    Through introduction of steam turbine shift seal renovation in No.9 unit high and middle pressure cylinder at shanghai wujing thermal power plant, the article analyzes working principle, technical characteristics, installation process and renovation implementation of steam turbine shift seal renovation. It shows that steam turbine shift seal renovation could improve steam turbine thermal economy and improve steam turbine operation safety, which could be widely used in same type 300MW units in shanghai steam turbine factory.%通过上海9号机组高中压缸进行的汽轴封改造的介绍,对改造汽封的工作原理、技术特性、安装工艺及改造实施情况进行了比较详尽的分析。指出了汽封改造对提高汽轮机的热经济性和提高汽轮机运行的安全性都有较好的效果,可以广泛的推广到尚在运行的同类型上汽300MW机组的技术改造过程中去。

  13. Estimation of ex-vessel steam explosion pressure loads

    Energy Technology Data Exchange (ETDEWEB)

    Leskovar, Matjaz [Jozef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia)], E-mail: matjaz.leskovar@ijs.si; Ursic, Mitja [Jozef Stefan Institute, Jamova cesta 39, SI-1000 Ljubljana (Slovenia)

    2009-11-15

    An ex-vessel steam explosion may occur when, during a severe reactor accident, the reactor vessel fails and the molten core pours into the water in the reactor cavity. A steam explosion is a fuel coolant interaction process where the heat transfer from the melt to water is so intense and rapid that the timescale for heat transfer is shorter than the timescale for pressure relief. This can lead to the formation of shock waves and production of missiles that may endanger surrounding structures. A strong enough steam explosion in a nuclear power plant could jeopardize the containment integrity and so lead to a direct release of radioactive material to the environment. In this article, different scenarios of ex-vessel steam explosions in a typical pressurized water reactor cavity are analyzed with the code MC3D, which is being developed for the simulation of fuel-coolant interactions. A parametric study was performed varying the location of the melt release (central, right and left side melt pour), the cavity water subcooling, the primary system overpressure at vessel failure and the triggering time for explosion calculations. The main purpose of the study was to establish the influence of the varied parameters on the fuel-coolant interaction behaviour, to determine the most challenging cases and to estimate the expected pressure loadings on the cavity walls. For the most explosive central, right side and left side melt pour scenarios a detailed analysis of the explosion simulation results was performed. The study shows that for some ex-vessel steam explosion scenarios higher pressure loads are predicted than obtained in the OECD programme SERENA phase 1.

  14. The longest steam piping of Darmstadt saves enormous amounts of CO{sub 2}; Darmstadts laengste Dampfleitung spart gewaltige Mengen CO{sub 2} ein

    Energy Technology Data Exchange (ETDEWEB)

    Onkelbach, Guenter [HSE Technik GmbH und Co. KG, Darmstadt (Germany). Bau Rohrnetze

    2013-06-01

    A 1.5 km long steam pipeline DN 250 across Darmstadt (Federal Republic of Germany) provides the world's leading methacrylate specialist Evonik Industries with steam from the waste-fuelled power plant of the Zweckverband Abfallverwertung Suedhessen (Darmstadt, Federal Republic of Germany). Up to 90,000 tonnes of steam per year are provided for the production and heating of this company. Up to 14,000 tonnes of carbon dioxide can be saved annually.

  15. Microfabricated rankine cycle steam turbine for power generation and methods of making the same

    Science.gov (United States)

    Frechette, Luc (Inventor); Muller, Norbert (Inventor); Lee, Changgu (Inventor)

    2009-01-01

    In accordance with the present invention, an integrated micro steam turbine power plant on-a-chip has been provided. The integrated micro steam turbine power plant on-a-chip of the present invention comprises a miniature electric power generation system fabricated using silicon microfabrication technology and lithographic patterning. The present invention converts heat to electricity by implementing a thermodynamic power cycle on a chip. The steam turbine power plant on-a-chip generally comprises a turbine, a pump, an electric generator, an evaporator, and a condenser. The turbine is formed by a rotatable, disk-shaped rotor having a plurality of rotor blades disposed thereon and a plurality of stator blades. The plurality of stator blades are interdigitated with the plurality of rotor blades to form the turbine. The generator is driven by the turbine and converts mechanical energy into electrical energy.

  16. Steam oxidation and the evaluation of coatings and material performance through collaborative research

    Energy Technology Data Exchange (ETDEWEB)

    Fry, A.T. [National Physical Lab., Teddington (United Kingdom); Aguero, A. [INTA, Madrid (Spain)

    2010-07-01

    Over the last five years through the COST 536 Programme researchers across Europe have been collaborating to better understand the phenomena of steam oxidation and to characterise coated and uncoated materials for use in power plants. During this period fundamental study of the oxidation mechanisms and changes in the oxidation kinetics caused by the presence of steam have been undertaken. Materials covering a range of high temperature plant applications have been studied, from low alloy martensitic alloys through to Ni-based superalloy materials, with investigations into the effect of increasing temperatures and pressures on the oxidation kinetics, oxide morphology and spallation characteristics. In addition conventional and novel coatings have been evaluated to assess their potential use in new USC plant. This paper will present an overview of these activities demonstrating the effect that steam has on the oxidation of alloys and coatings. (orig.)

  17. Steam reforming of crude glycerol with in situ CO(2) sorption.

    Science.gov (United States)

    Dou, Binlin; Rickett, Gavin L; Dupont, Valerie; Williams, Paul T; Chen, Haisheng; Ding, Yulong; Ghadiri, Mojtaba

    2010-04-01

    Steam reforming of the crude glycerol by-product of a biodiesel production plant has been evaluated experimentally at atmospheric pressure, with and without in situ CO(2) sorption, in a continuous flow fixed-bed reactor between 400 degrees C and 700 degrees C. The process outputs were compared to those using pure glycerol. Thermodynamic equilibrium calculations were used to assess the effect on the steam reforming process of the main crude impurities (methanol and four fatty acid methyl esters). The crude glycerol and steam conversions and the H(2) purity reached 100%, 11% and 68%, respectively at 600 degrees C. No CH(4) was found at and above 600 degrees C. Steam reforming of crude glycerol with in situ CO(2) removal is shown to be an effective means of achieving hydrogen purity above 88% in pre-CO(2) breakthrough conditions.

  18. Control concepts for direct steam generation in parabolic troughs

    Energy Technology Data Exchange (ETDEWEB)

    Valenzuela, Loreto; Zarza, Eduardo [CIEMAT, Plataforma Solar de Almeria, Tabernas (Almeria) (Spain); Berenguel, Manuel [Universidad de Almeria, Dept. de Lenguajes y Computacion, Almeria (Spain); Camacho, Eduardo F. [Universidad de Sevilla, Dept. de Ingenieria de Sistemas y Automatica, Sevilla (Spain)

    2005-02-01

    A new prototype parabolic-trough collector system was erected at the Plataforma Solar de Almeria (PSA) (1996-1998) to investigate direct steam generation (DSG) in a solar thermal power plant under real solar conditions. The system has been under evaluation for efficiency, cost, control and other parameters since 1999. The main objective of the control system is to obtain steam at constant temperature and pressure at the solar field outlet, so that changes in inlet water conditions and/or in solar radiation affect the amount of steam, but not its quality or the nominal plant efficiency. This paper presents control schemes designed and tested for two operating modes, 'Recirculation', for which a proportional-integral-derivative (PI/PID) control functions scheme has been implemented, and 'Once-through', requiring more complex control strategies, for which the scheme is based on proportional-integral (PI), feedforward and cascade control. Experimental results of both operation modes are discussed. (Author)

  19. Alternate tube plugging criteria for steam generator tubes

    Energy Technology Data Exchange (ETDEWEB)

    Cueto-Felgueroso, C.; Aparicio, C.B. [Tecnatom, S.A., Madrid (Spain)

    1997-02-01

    The tubing of the Steam Generators constitutes more than half of the reactor coolant pressure boundary. Specific requirements governing the maintenance of steam generator tubes integrity are set in Plant Technical Specifications and in Section XI of the ASME Boiler and Pressure Vessel Code. The operating experience of Steam Generator tubes of PWR plants has shown the existence of some types of degradatory processes. Every one of these has an specific cause and affects one or more zones of the tubes. In the case of Spanish Power Plants, and depending on the particular Plant considered, they should be mentioned the Primary Water Stress Corrosion Cracking (PWSCC) at the roll transition zone (RTZ), the Outside Diameter Stress Corrosion Cracking (ODSCC) at the Tube Support Plate (TSP) intersections and the fretting with the Anti-Vibration Bars (AVBs) or with the Support Plates in the preheater zone. The In-Service Inspections by Eddy Currents constitutes the standard method for assuring the SG tubes integrity and they permit the monitoring of the defects during the service life of the plant. When the degradation reaches a determined limit, called the plugging limit, the SG tube must be either repaired or retired from service by plugging. Customarily, the plugging limit is related to the depth of the defect. Such depth is typically 40% of the wall thickness of the tube and is applicable to any type of defect in the tube. In its origin, that limit was established for tubes thinned by wastage, which was the predominant degradation in the seventies. The application of this criterion for axial crack-like defects, as, for instance, those due to PWSCC in the roll transition zone, has lead to an excessive and unnecessary number of tubes being plugged. This has lead to the development of defect specific plugging criteria. Examples of the application of such criteria are discussed in the article.

  20. Measuring steam generator performance using non-intrusive downcomer flow measurements

    Energy Technology Data Exchange (ETDEWEB)

    Taylor, C.E.; McGregor, J.E.; Kittmer, C.A. [Atomic Energy of Canada Limited, Chalk River, Ontario (Canada)

    1998-07-01

    Nuclear plant reliability depends directly on steam generator performance. Downcomer flow is a good monitor of steam generator performance. It provides information critical to the efficient and safe operation of steam generators as determined by the recirculation ratio and water inventory. In addition, reduced downcomer flow may indicate steam generator crudding or inadequate chemical cleaning. This paper describes recent advances in the application of ultrasonic technology to measure flow velocity in the downcomer annulus during operation. This technique is non-intrusive since the measurements are taken with ultrasonic transducers mounted on the outer shell of the steam generator. New transducers and improved installation techniques have resulted in increased transducer reliability. Through on-site testing, it was determined that some CANDU steam generators are experiencing carry-under (steam from the separators is carried into the downcomer). To measure the downcomer flow under these conditions, a different ultrasonic technique was required. A new technique became available in 1995 and was successfully adapted for high-temperature application. This transflection method was attached to a Bruce A steam generator in January of 1996. Whereas previous installations provided data for two to three months, this installation was still operating when the reactors were shut down in 1997. Options for movable measuring systems and simpler surface preparation have also been examined. This research has determined several obstacles and some possibilities for the use of magnets in temporarily holding the transducers at a given location. This would allow for measurements to be taken in a larger number of locations using the same flow measurement system. In addition, the need for minor welding on the surface of the steam generator shell would be eliminated. (author)

  1. An installation for steam conversion of gases

    Energy Technology Data Exchange (ETDEWEB)

    Tabata, K.; Matsumoto, I.

    1983-01-28

    An installation is proposed for steam conversion of a hydrocarbon gas in order to produce an inorganic gas which chiefly consists of H2 and CO in which the line for feeding the hydrocarbon gas has a steam generator which has a microcapillary structure made of sponge metal, inorganic heat resistant fibers of glass, Si02, Al203 or carbon, inorganic heat resistant fibers twisted into a fiber or a cord of multipore ceramic material; the installation is equipped with a heater which regulates the water temperature, in which the steam generator is submerged. The installation is designed for converting natural gas, C3H8, other hydrocarbon gases and vapors of liquid hydrocarbons (Uv) into H2 and CO. The design and disposition of the steam generator simplify the design of the device, eliminating the pump for feeding the steam and the device for premixing of the steam and hydrocarbon gas.

  2. PWR steam generator chemical cleaning, Phase I. Final report

    Energy Technology Data Exchange (ETDEWEB)

    Rothstein, S.

    1978-07-01

    United Nuclear Industries (UNI) entered into a subcontract with Consolidated Edison Company of New York (Con Ed) on August 8, 1977, for the purpose of developing methods to chemically clean the secondary side tube to tube support crevices of the steam generators of Indian Point Nos. 1 and 2 PWR plants. This document represents the first reporting on activities performed for Phase I of this effort. Specifically, this report contains the results of a literature search performed by UNI for the purpose of determining state-of-the-art chemical solvents and methods for decontaminating nuclear reactor steam generators. The results of the search sought to accomplish two objectives: (1) identify solvents beyond those proposed at present by UNI and Con Ed for the test program, and (2) confirm the appropriateness of solvents and methods of decontamination currently in use by UNI.

  3. Exergoeconomic analysis of small-scale biomass steam cogeneration

    Energy Technology Data Exchange (ETDEWEB)

    Rodriguez Sotomonte, Cesar Adolfo; Lora, Electo Eduardo Silva [Universidade Federal de Itajuba, MG (Brazil)], e-mails: c.rodriguez32@unifei.edu.br, electo@unifei.edu.br; Venturini, Osvaldo Jose; Escobar, Jose Carlos [Universidad Federal de Itajuba, MG (Brazil)], e-mail: osvaldo@unifei.edu.br

    2010-07-01

    The principal objective of this work is to develop a calculation process, based on the second law of thermodynamics, for evaluating the thermoeconomic potential of a small steam cogeneration plant using waste from pulp processing and/or sawmills as fuel. Four different configurations are presented and assessed. The exergetic efficiency of the cycles that use condensing turbines is found to be around 11%, which has almost 3 percent higher efficiency than cycles with back pressure turbines. The thermoeconomic equations used in this paper estimated the production costs varying the fuel price. The main results show that present cost of technologies in a small-scale steam cycle cogeneration do not justify the implementation of more efficient systems for biomass prices less than 100 R$/t. (author)

  4. Analysis of performance for centrifugal steam compressor

    Energy Technology Data Exchange (ETDEWEB)

    Kang, Seung Hwan; Ryu, Chang Kook; Ko, Han Seo [Sungkyunkwan University, Suwon (Korea, Republic of)

    2016-12-15

    In this study, mean streamline and Computational fluid dynamics (CFD) analyses were performed to investigate the performance of a small centrifugal steam compressor using a latent heat recovery technology. The results from both analysis methods showed good agreement. The compression ratio and efficiency of steam were found to be related with those of air by comparing the compression performances of both gases. Thus, the compression performance of steam could be predicted by the compression performance of air using the developed dimensionless parameters.

  5. Loss of feed flow, steam generator tube rupture and steam line break thermohydraulic experiments

    Energy Technology Data Exchange (ETDEWEB)

    Mendler, O J; Takeuchi, K; Young, M Y

    1986-10-01

    The Westinghouse Model Boiler No. 2 (MB-2) steam generator test model at the Engineering Test Facility in Tampa, Florida, was reinstrumented and modified for performing a series of tests simulating steam generator accident transients. The transients simulated were: loss of feed flow, steam generator tube rupture, and steam line break events. This document presents a description of (1) the model boiler and the associated test facility, (2) the tests performed, and (3) the analyses of the test results.

  6. Design of Multi Cleaning System Using Steam

    Directory of Open Access Journals (Sweden)

    Abhijeetsinh v Makwana

    2016-11-01

    Full Text Available The multi cleaning system is supposed to be system that uses steam which can clean up things that are used by human in day to day life. The commercial detergent washers are compared with the system and it was found that the washing is very convenient and soapy forms are not produced that made the washing very clumsy. The removal of bacterial populations formed on surface of any material would be totally eradicated. The surface to be cleaned are given bath with steam with high pressure from 3 bar to 7 bar by which removal of dirt and stain particles were washed off very comfortably. High pressure steam would be generated by heat the water in the tank which will mounted on the system itself. The reason behind using the steam for washing purpose is the less wastage of water and also its availability. The development of steam based cleaning system has revolutionized the process of washing. One can choose an appropriate type of high power steam cleaners for challenging cleaning applications in office, commercial and industrial settings. The steam does that thing that commercial washing system cannot do. A steam can remove grease and grime while for normal cleaning requires expensive detergents. The multi cleaning system cannot be only used for industrial use but also for the housework stuff. So our prime focus is to use the steam and make multiple cleaning

  7. Amazing & extraordinary facts the steam age

    CERN Document Server

    Holland, Julian

    2012-01-01

    Respected transport author Julian Holland delves into the intriguing world of steam in his latest book, which is full of absorbing facts and figures on subjects ranging from Cornish beam engines, steam railway locomotives, road vehicles and ships through to traction engines, steam rollers and electricity generating stations and the people who designed and built them. Helped along the way by the inventive minds of James Watt, Richard Trevithick and George Stephenson, steam became the powerhouse that drove the Industrial Revolution in Britain in the late 18th and 19th centuries.

  8. Efficiency of Modern Power Plants of Thermal Power Stations

    Directory of Open Access Journals (Sweden)

    B. V. Yakovlev

    2007-01-01

    Full Text Available The paper considers efficiency and prospects in development of different types of fossil-fuel power plants – gas turbine, steam turbine and combined (gas and steam cycles.The paper provides information on plant selection, fuel consumption, specific output cost. It describes main advantages of various power plants.

  9. Integration of mixed conducting membranes in an oxygen–steam biomass gasification process

    DEFF Research Database (Denmark)

    Puig Arnavat, Maria; Soprani, Stefano; Søgaard, Martin

    2013-01-01

    Oxygen–steam biomass gasification produces a high quality syngas with a high H2/CO ratio that is suitable for upgrading to liquid fuels. Such a gas is also well suited for use in conjunction with solid oxide fuel cells giving rise to a system yielding high electrical efficiency based on biomass....... The two configurations demonstrating the highest efficiency are then thermally integrated into an oxygen– steam biomass gasification plant. The energy demand for oxygen production and the membrane area required for a 6 MWth biomass plant are calculated for different operating conditions. Increasing...

  10. Popular culture and sporting life in the rural margins of late eighteenth-century England: the world of Robert Anderson, "The Cumberland Bard".

    Science.gov (United States)

    Huggins, Mike

    2012-01-01

    This study sets out to extend and challenge existing historiography on late eighteenth century British popular culture, customary sports, class and cultural identity, focusing upon the rural geo-political borderland of England. It suggests that prevailing class-based and more London-biased studies need to be balanced with more regionalist-based work, and shows the importance of northern regional leisure variants. The textual and historical analysis draws largely on the published works of a neglected working-class dialect poet, Robert Anderson, living and working in Cumberland, arguing that he represented a strain of ''bardic regionalism,'' a variant of Katie Trumpener’s ''bardic nationalism.''

  11. Steam Flooding after Steam Soak in Heavy Oil Reservoirs through Extended-reach Horizontal Wells

    Institute of Scientific and Technical Information of China (English)

    Ning Zhengfu; Liu Huiqing; Zhang Hongling

    2007-01-01

    This paper presents a new development scheme of simultaneous injection and production in a single horizontal well drilled for developing small block reservoirs or offshore reservoirs.It is possible to set special packers within the long completion horizontal interval to establish an injection zone and a production zone.This method can also be used in steam flooding after steam soak through a horizontal well.Simulation results showed that it was desirable to start steam flooding after six steam soaking cycles and at this time the oil/steam ratio was 0.25 and oil recovery efficiency was 23.48%.Steam flooding performance was affected by separation interval and steam injection rate.Reservoir numerical simulation indicated that maximum oil recovery would be achieved at a separation section of 40-50 m at steam injection rate of 100-180 t/d; and the larger the steam injection rate,the greater the water cut and pressure difference between injection zone and production zone.A steam injection rate of 120 t/d was suitable for steam flooding under practical injection-production conditions.All the results could be useful for the guidance of steam flooding projects.

  12. Steam and fuel oil supply and purge valve with cooling steam feature

    Energy Technology Data Exchange (ETDEWEB)

    Buchanan, B.F.; Buchanan, J.R.

    1991-09-17

    This patent describes a steam and fuel oil supply and purge valve. It comprises a valve body defining steam and oil inlet ports, at least one discharge port, a steam purge passageway interconnecting the steam inlet and discharge ports, an oil supply passageway interconnecting the oil inlet and discharge ports, a cooling steam passageway interconnecting the steam inlet and discharge ports, a steam valve and actuator member movable between first, second, third, and fourth positions in the valve body and operable to open and close the steam purge and cooling steam passageways, a small metering passageway in the steam valve and actuator member which is so dimensioned and located as to open prior to full opening movement of the valve member and actuator relative to its seat, an oil valve member movable between first and second positions to open and close the oil supply passageway, biasing means urging the oil valve member toward its second and closed positions, the steam valve and actuator member in its first and second positions respectively closing and opening the steam purge passageway.

  13. The Multimodel-based Active Disturbance Rejection Control for Water Level of Steam Generator in Nuclear Power Plants%核电站蒸汽发生器水位的自抗扰多模型控制方法研究

    Institute of Scientific and Technical Information of China (English)

    谷俊杰; 冀乃良; 孙玉洁; 谭俊龙; 王东旭

    2012-01-01

    Considering the nonlinear distribution characteristics of water level control for steam generator in nuclear power plants,a novel control strategy is proposed in combination of active disturbance rejection technology with multimodel-based control,in which a multimodel-based control system is designed for the steam generator,and an independent active disturbance rejection controller is prepared for each model under different loading conditions,so as to realize online estimation at extended states,and achieve prompt disturbance elimination by independent disturbance compensation.Simulation results show that the control strategy can help to realize accurate dynamic control for water level of steam generator,which is featured by strong robustness,high disturbance rejection capability,simple computation and facile commissioning.%针对核电站蒸汽发生器水位控制的非线性分布特点,在自抗扰控制技术的基础上结合多模型控制提出了蒸汽发生器水位系统新的控制方案.在该控制方案中,对蒸汽发生器设计了多模型控制系统,并针对各个模型分别设计了不同负荷下的自抗扰控制器,可以对扩张状态进行在线实时估计,因此设计的扰动补偿不依赖于模型便能够达到快速消去扰动的效果.将该方法用于蒸汽发生器水位控制系统进行仿真研究,结果表明:该控制方案实现了对蒸汽发生器水位良好的动态控制,具有较强的鲁棒性和抗干扰能力,且算法简单,便于调试.

  14. Steam microturbines in distributed cogeneration

    CERN Document Server

    Kicinski, Jan

    2014-01-01

    This book presents the most recent trends and concepts in power engineering, especially with regard to prosumer and civic energy generation. In so doing, it draws widely on his experience gained during the development of steam microturbines for use in small combined heat and power stations based on the organic Rankine cycle (CHP-ORC). Major issues concerning the dynamic properties of mechanical systems, in particular rotating systems, are discussed, and the results obtained when using unconventional bearing systems, presented. Modeling and analysis of radial-flow and axial-flow microturbines a

  15. Recent operating experiences with steam generators in Japanese NPPs

    Energy Technology Data Exchange (ETDEWEB)

    Yashima, Seiji [Japan Power Engineering and Inspection Corp., Tokyo (Japan)

    1997-02-01

    In 1994, the Genkai-3 of Kyushu Electric Power Co., Inc. and the Ikata-3 of Shikoku Electric Power Co., Inc. started commercial operation, and now 22 PWR plants are being operated in Japan. Since the first PWR plant now 22 PWR plants are being operated in was started to operate, Japanese PWR plants have had an operating experience of approx. 280 reactor-years. During that period, many tube degradations have been experienced in steam generators (SGs). And, in 1991, the steam generator tube rupture (SGTR) occurred in the Mihama-2 of Kansai Electric Power Co., Inc. However, the occurrence of tube degradation of SGs has been decreased by the instructions of the MITI as regulatory authorities, efforts of Electric Utilities, and technical support from the SG manufacturers. Here the author describes the recent SGs in Japan about the following points. (1) Recent Operating Experiences (2) Lessons learned from Mihama-2 SGTR (3) SG replacement (4) Safety Regulations on SG (5) Research and development on SG.

  16. 2D-simulation of wet steam flow in a steam turbine with spontaneous condensation

    Institute of Scientific and Technical Information of China (English)

    SUN Lan-xin; ZHENG Qun; LIU Shun-long

    2007-01-01

    Removal of condensates from wet steam flow in the last stages of steam turbines significantly promotes stage efficiency and prevents erosion of rotors. In this paper, homogeneous spontaneous condensation in transonic steam flow in the 2-D rotor-tip section of a stage turbine is investigated.Calculated results agree with experimental data reasonably well. On the basis of the above work, a 2-D numerical simulation of wet steam flow in adjacent root sections of a complex steam turbine stage was carried out. Computational results were analyzed and provide insights into effective removal of humidity.

  17. Modelling 3D Steam Turbine Flow Using Thermodynamic Properties of Steam Iapws-95

    Directory of Open Access Journals (Sweden)

    Rusanow A.V.

    2016-01-01

    Full Text Available An approach to approximate equations of state for water and steam (IAPWS-95 for the calculation of three-dimensional flows of steam in turbomachinery in a range of operation of the present and future steam turbines is described. Test calculations of three-dimensional viscous flow in an LP steam turbine using various equations of state (perfect gas, Van der Waals equation, equation of state for water and steam IAPWS-95 are made. The comparison of numerical results with experimental data is also presented.

  18. Steam chemistry - interaction of chemical species with water, steam, and materials during evaporation, superheating, and condensation. Proceedings

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1999-07-01

    Topics of this proceedings are: steam chemistry, supercritical water, effects of chemicals in steam (acetic acid, formic acid, phosphoric acid or other impurities); solubility and deposition, condensation processes and effect of impurities; nucleation; gas-liquid interfaces; steam treatment. (SR)

  19. Optimizing steam flood performance utilizing a new and highly accurate two phase steam measurement system

    Energy Technology Data Exchange (ETDEWEB)

    Huff, B. D.; Warren, P. B. [CalResources LLC (Canada); Whorff, F. [ITT Barton (Canada)

    1995-11-01

    The development of a two phase steam measurement system was documented. The system consists of a `V` cone differential pressure device and a vortex meter velocity device in series through which the steam flows. Temperature and pressure sensors are electronically interfaced with a data logging system. The design was described as being very simple and rugged, consequently, well suited to monitoring in the field.. Steam quality measurements were made in the Kern River Field and the Coalinga Field thermal projects using a surface steam separator. In steam flood operations, steam cost is very high, hence appropriate distribution of the steam can result in significant cost reduction. This technology allows the measurement of steam flow and quality at any point in the steam distribution system. The metering system`s orifice meter was found to have a total average error of 45%, with 25% of that attributable to `cold leg` problem. Installation of the metering system was expected to result in a steam use reduction of 8%, without any impact on production. Steam re-distribution could result in a potential oil production increase of 10%. 12 refs., 8 tabs., 9 figs.

  20. Third international seminar on horizontal steam generators

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1995-12-31

    The Third International Seminar on Horizontal Steam Generators held on October 18-20, 1994 in Lappeenranta, consisted of six sessions dealing with the topics: thermal hydraulic experiments and analyses, primary collector integrity, management of primary-to-secondary leakage accidents, feedwater collector replacement and discussion of VVER-440 steam generator safety issues.

  1. The Invention of the Steam Engine

    NARCIS (Netherlands)

    Van der Kooij, B.J.G.

    2015-01-01

    This casestudy is a historic analysis of the developments that resulted in the steam engine. The range of inventions that started with Savery's 'Miner's Friend' (a water pump to solve the dramatic water problem in the British eighteenth century mines) over a century culminated in the steam engine us

  2. Steam generated conversion coating on aluminium alloys

    DEFF Research Database (Denmark)

    Din, Rameez Ud; Jellesen, Morten Stendahl; Ambat, Rajan

    pressure steam produced by an autoclave at a temperature of 107 – 121 °C and pressure of 15 -17 psi for 10 minutes to produce a thin coating of aluminium oxide. The aim of this study is to understand the effect of high pressure steam with and without different chemical additives on surface morphology...

  3. Future trends in steam coal utilization

    Energy Technology Data Exchange (ETDEWEB)

    Broadbent, G.A. [IEA Coal Research, London (United Kingdom)

    2000-07-01

    After reviewing the history of coal production in important regions of the world and the evolution of the international steam coal trade, the paper examines the main drivers behind the future use of steam coal and looks at, from past evidence and current perception, how these may shape the future. The four main drivers are social issues, strategic issues, competitiveness issues, and environmental issues.

  4. The Invention of the Steam Engine

    NARCIS (Netherlands)

    Van der Kooij, B.J.G.

    2015-01-01

    This casestudy is a historic analysis of the developments that resulted in the steam engine. The range of inventions that started with Savery's 'Miner's Friend' (a water pump to solve the dramatic water problem in the British eighteenth century mines) over a century culminated in the steam engine us

  5. Steam generator tubing NDE performance

    Energy Technology Data Exchange (ETDEWEB)

    Henry, G. [Electric Power Research Institute, Charlotte, NC (United States); Welty, C.S. Jr. [Electric Power Research Institute, Palo Alto, CA (United States)

    1997-02-01

    Steam generator (SG) non-destructive examination (NDE) is a fundamental element in the broader SG in-service inspection (ISI) process, a cornerstone in the management of PWR steam generators. Based on objective performance measures (tube leak forced outages and SG-related capacity factor loss), ISI performance has shown a continually improving trend over the years. Performance of the NDE element is a function of the fundamental capability of the technique, and the ability of the analysis portion of the process in field implementation of the technique. The technology continues to improve in several areas, e.g. system sensitivity, data collection rates, probe/coil design, and data analysis software. With these improvements comes the attendant requirement for qualification of the technique on the damage form(s) to which it will be applied, and for training and qualification of the data analysis element of the ISI process on the field implementation of the technique. The introduction of data transfer via fiber optic line allows for remote data acquisition and analysis, thus improving the efficiency of analysis for a limited pool of data analysts. This paper provides an overview of the current status of SG NDE, and identifies several important issues to be addressed.

  6. Steam reforming of light oxygenates

    DEFF Research Database (Denmark)

    Trane-Restrup, Rasmus; Resasco, Daniel E; Jensen, Anker Degn

    2013-01-01

    Steam reforming (SR) of ethanol, acetic acid, acetone, acetol, 1-propanol, and propanal has been investigated over Ni/MgAl2O4 at temperatures between 400 and 700 degrees C and at a steam-to-carbon-ratio (S/C) of 6. The yield of H-2 and conversion increased with temperature, while the yield of by-products...... decreased with temperature in the SR of the investigated compounds. The yield of H2 approached the thermodynamic limit at the highest temperatures investigated. No significant differences in conversion as a function of temperature among the different model compounds were observed. However, the product...... distribution depended on the model compound, and C-3-oxygenates produced a larger fraction of by-products compared to C-2-oxygenates. Temperatures of 600 degrees C or above were generally needed to minimize the fraction of by-products and obtain a syngas containing mainly CO, CO2, H-2, and H2O with only traces...

  7. 试论火力发电厂汽机辅机现状及优化策略%On the Current Situation and Optimization Strategies of Thermal Power Plant Steam Turbine Auxiliary

    Institute of Scientific and Technical Information of China (English)

    辛继群; 梁健

    2013-01-01

    随着我国社会的不断进步,经济的快速发展,对火力发电需求越来越高,汽机辅机是整个火力发电中的一个重要组成部分,它在火力发电中起到了决定性的作用。可随着现在用电量的日渐加大,火力发电厂的发电量也在逐日上涨,这对汽机辅机造成了一定程度的影响。%With the continuous progress of our society and the rapid economic development, the demand for power generation is increasing. Steam turbine auxiliary is an important part in the whole power generation, and it plays a decisive role in thermal power. With the gradually increased electricity consumption, the generating capacity of thermal power is also rising day by day, which has caused a certain influence on the auxiliary turbine.

  8. 西钢焦化低温余热蒸汽回收利用%Recovery and reutilization of low temperature waste heat steam of coking plant of XiSteel

    Institute of Scientific and Technical Information of China (English)

    杨凤君; 王洋; 刘延东; 丛东杰; 崔柏

    2014-01-01

    Refrigeration process is applied to the chilled water at the lower stage of COG cooler,and open cycle is switched to closed cycle,so that water temperature is reduced by 10~ 15℃,meeting the process requirement. After comissioning and start-up, cooling water flow reaches 200m3 / h, CO2 emission is reduced by 12 000t / a,steam recovered by 69 120t / a,and water saved by 1 400 000m3 / a. The energy saving and emission reduction effect is remarkable.%将制冷工艺应用到焦炉煤气冷却器下段低温用水,变开路循环为闭路循环,水温降低10~15益,满足了工艺需求。通过调试和投入运行,制冷水量达到200m3/ h,年减排二氧化碳12000t,回收蒸汽69120t,节约水耗140万m3,节能减排效果显著。

  9. Steam oxidation scale growth and thermal insulation effect on creep life of creep strength enhanced ferritic steels

    Energy Technology Data Exchange (ETDEWEB)

    Masuyama, Fujimitsu; Tokunaga, Tatsuya [Kyushu Inst. of Technology (Japan). Graduate School of Engineering; Takao, Mikito [Kyushu Inst. of Technology (Japan). Graduate School of Engineering; JFE Steel Corporation (Japan); Arakawa, Katsutoshi [Kyushu Inst. of Technology (Japan). Graduate School of Engineering; Kobe Steel Ltd. (Japan)

    2010-07-01

    Creep strength enhanced ferritic steels, such as T91 and T23 are extensively used worldwide for superheater and reheater tubes, not only in advanced power plants but also in plants with conventional steam conditions. However when these steel tubes are used at higher metal temperature, steam oxidation problems are recently experienced resulting in turbine side erosion, and overheating of tubes leading to creep rupture due to scale blockage in tube bends or scale insulation effect due to thick scale, and separation and exfoliation of the scale. In the present study, steam oxidation growth tests of T91, T92, T23 and T22 were conducted to develop steam oxidation growth rate and scale behavior. Then using the steam oxidation growth data measured the metal temperature changes with scale growth were calculated considering the insulation effect of steam oxidation scale. Consequently the creep lives affected by steam oxidation scale growth were predicted as a function of time and temperature increase for creep strength enhanced ferritic steels. (orig.)

  10. Power plant chemical technology

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1996-12-01

    17 contributions covering topies of fossil fuel combustion, flue gas cleaning, power plant materials, corrosion, water/steam cycle chemistry, monitoring and control were presented at the annual meeting devoted to Power Plant Chemical Technology 1996 at Kolding (Denmark) 4-6 September 1996. (EG)

  11. Station power supply by residual steam of Fugen

    Energy Technology Data Exchange (ETDEWEB)

    Kamiya, Y.; Kato, H.; Hattori, S. (Power Reactor and Nuclear Fuel Development Corp., Tokyo (Japan))

    1981-09-01

    In the advanced thermal reactor ''Fugen'', when the sudden decrease of load more than 40% occurs due to the failure of power system, the turbine regulating valve is rapidly shut, and the reactor is brought to scrum. However, the operation of turbo-generators is continued with the residual steam in the reactor, and the power for inside the station is supplied for 30 sec by the limiting timer, then the power-generating plant is automatically stopped. The reasons why such design was adopted are to reduce manual operation at the time of emergency, to continue water supply for cooling the reactor and to maintain the water level in the steam drum, and to reduce steam release from the safety valve and the turbine bypass valve. The output-load unbalance relay prevents the everspeed of the turbo-generator when load decreased suddenly, but when the failure of power system is such that recovers automatically in course of time, it does not work. The calculation for estimating the dynamic characteristics at the time of the sole operation within the station is carried out by the analysis code FATRAC. The input conditions for the calculation and the results are reported. Also the dynamic characteristics were actually tested to confirm the set value of the limiting timer and the safe working of turbine and generator trips. The estimated and tested results were almost in agreement.

  12. Steam Generator tube integrity -- US Nuclear Regulatory Commission perspective

    Energy Technology Data Exchange (ETDEWEB)

    Murphy, E.L.; Sullivan, E.J.

    1997-02-01

    In the US, the current regulatory framework was developed in the 1970s when general wall thinning was the dominant degradation mechanism; and, as a result of changes in the forms of degradation being observed and improvements in inspection and tube repair technology, the regulatory framework needs to be updated. Operating experience indicates that the current U.S. requirements should be more stringent in some areas, while in other areas they are overly conservative. To date, this situation has been dealt with on a plant-specific basis in the US. However, the NRC staff is now developing a proposed steam generator rule as a generic framework for ensuring that the steam generator tubes are capable of performing their intended safety functions. This paper discusses the current U.S. regulatory framework for assuring steam generator (SG) tube integrity, the need to update this regulatory framework, the objectives of the new proposed rule, the US Nuclear Regulatory Commission (NRC) regulatory guide (RG) that will accompany the rule, how risk considerations affect the development of the new rule, and some outstanding issues relating to the rule that the NRC is still dealing with.

  13. The chemistry involved in the steam treatment of lignocellulosic materials

    Directory of Open Access Journals (Sweden)

    Luiz Pereira Ramos

    2003-12-01

    Full Text Available Pretreatment of lignocellulosic materials is essential for bioconversion because of the various physical and chemical barriers that greatly inhibit their susceptibility to bioprocesses such as hydrolysis and fermentation. The aim of this article is to review some of the most important pretreatment methods developed to date to enhance the conversion of lignocellulosics. Steam explosion, which precludes the treatment of biomass with high-pressure steam under optimal conditions, is presented as the pretreatment method of choice and its mode of action on lignocellulosics is discussed. The optimal pretreatment conditions for a given plant biomass are defined as those in which the best substrate for hydrolysis is obtained with the least amount of soluble sugars lost to side reactions such as dehydration. Therefore, pretreatment optimization results from a compromise between two opposite trends because hemicellulose recovery in acid hydrolysates can only be maximized at lower pretreatment severities, whereas the development of substrate accessibility requires more drastic pretreatment conditions in which sugar losses are inevitable. To account for this heterogeneity, the importance of several process-oriented parameters is discussed in detail, such as the pretreatment temperature, residence time into the steam reactor, use of an acid catalyst, susceptibility of the pretreated biomass to bioconversion, and process design.

  14. Steam reforming of low-level mixed waste. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    ThermoChem has successfully designed, fabricated and operated a nominal 90 pound per hour Process Development Unit (PDU) on various low-level mixed waste surrogates. The design, construction, and testing of the PDU as well as performance and economic projections for a 300-lb/hr demonstration and commercial system are described. The overall system offers an environmentally safe, non-incinerating, cost-effective, and publicly acceptable method of processing LLMW. The steam-reforming technology was ranked the No. 1 non-incineration technology for destruction of hazardous organic wastes in a study commissioned by the Mixed Waste Focus Area and published in April 1997. The ThermoChem steam-reforming system has been developed over the last 13 years culminating in this successful test campaign on LLMW surrogates. Six surrogates were successfully tested including a 750-hour test on material simulating a PCB- and Uranium-contaminated solid waste found at the Portsmouth Gaseous Diffusion Plant. The test results indicated essentially total (> 99.9999%) destruction of RCRA and TSCA hazardous halogenated organics, significant levels of volume reduction (> 400 to 1), and retention of radionuclides in the volume-reduced solids. Economic evaluations have shown the steam-reforming system to be very cost competitive with more conventional and other emerging technologies.

  15. Steam reforming of low-level mixed waste. Final report

    Energy Technology Data Exchange (ETDEWEB)

    NONE

    1998-06-01

    ThermoChem has successfully designed, fabricated and operated a nominal 90 pound per hour Process Development Unit (PDU) on various low-level mixed waste surrogates. The design, construction, and testing of the PDU as well as performance and economic projections for a 300-lb/hr demonstration and commercial system are described. The overall system offers an environmentally safe, non-incinerating, cost-effective, and publicly acceptable method of processing LLMW. The steam-reforming technology was ranked the No. 1 non-incineration technology for destruction of hazardous organic wastes in a study commissioned by the Mixed Waste Focus Area and published in April 1997. The ThermoChem steam-reforming system has been developed over the last 13 years culminating in this successful test campaign on LLMW surrogates. Six surrogates were successfully tested including a 750-hour test on material simulating a PCB- and Uranium-contaminated solid waste found at the Portsmouth Gaseous Diffusion Plant. The test results indicated essentially total (> 99.9999%) destruction of RCRA and TSCA hazardous halogenated organics, significant levels of volume reduction (> 400 to 1), and retention of radionuclides in the volume-reduced solids. Economic evaluations have shown the steam-reforming system to be very cost competitive with more conventional and other emerging technologies.

  16. Process Technology Development of Ni Electroplating in Steam Generator Tube

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Joung Soo; Kim, H. P.; Lim, Y. S.; Kim, S. S.; Hwang, S. S.; Yi, Y. S.; Kim, D. J.; Jeong, M. K.

    2009-11-15

    Operating nuclear power steam generator tubing material, Alloy 600, having superior resistance to corrosion has many experiences of damage by various corrosion mechanisms during long term operation period. In this research project, a new Ni electroplating technology to be applied to repair the damaged steam generator tubes has been developed. In this technology development, the optimum conditions for variables affecting the Ni electroplating process, optimum process conditions for maximum adhesion forces at interface between were established. The various mechanical properties (RT and HT tensile, fatigue, creep, burst, etc.) and corrosion properties (general corrosion, pitting, crevice corrosion, stress corrosion cracking, boric acid corrosion, doped steam) of the Ni plated layers made at the established optimum conditions have been evaluated and confirmed to satisfy the specifications. In addition, a new ECT probe developed at KAERI enable to detect defects from magnetic materials was confirmed to be used for Ni electroplated Alloy 600 tubes at the field. For the application of this developed technology to operating plants, a mock-up electroplating system has been designed and manufactured, and set up at Doosan Heavy Industry Co. and also its performance test has been done. At same time, the anode probe has been modified and improved to be used with the established mock-up system without any problem

  17. In-vessel coolability and steam explosion in Nordic BWRs

    Energy Technology Data Exchange (ETDEWEB)

    Ma, W.; Li, L.; Hansson, R.; Villanueva, W.; Kudinov, P.; Manickam, L.; Tran, C.-T. (Royal Institute of Technology (KTH) (Sweden))

    2011-05-15

    The objective of this research is to reduce the uncertainty in quantification of steam explosion risk and in-vessel coolability in the Nordic BWR plants which employ cavity flooding as severe accident management (SAM) strategy. To quantify the coolability of debris bed packed with irregular particles, the friction laws of fluid flow in particulate beds packed with non-spherical particles were investigated on the POMECO-FL test facility, and the experimental data suggest that the Ergun equation is applicable if the effective particle diameter of the particles is represented by the equivalent diameter of the particles, which is the product of Sauter mean diameter and shape factor of the particles. One-way coupling analysis between PECM model for melt pool heat transfer and ANSYS thermo-structural mechanics was performed to analyze the vessel creep, and the results revealed two different modes of vessel failure: a 'ballooning' of the vessel bottom and a 'localized creep' concentrated within the vicinity of the top surface of the melt pool. Single-droplet steam explosion experiments were carried out by using oxidic mixture of WO{sub 3}-CaO, and the results show an apparent difference in steam explosion energetics between the eutectic and non-eutectic melts at low melt superheat (100 deg. C). (Author)

  18. Design of fault tolerant control system for steam generator using

    Energy Technology Data Exchange (ETDEWEB)

    Kim, Myung Ki; Seo, Mi Ro [Korea Electric Power Research Institute, Taejon (Korea, Republic of)

    1998-12-31

    A controller and sensor fault tolerant system for a steam generator is designed with fuzzy logic. A structure of the proposed fault tolerant redundant system is composed of a supervisor and two fuzzy weighting modulators. A supervisor alternatively checks a controller and a sensor induced performances to identify which part, a controller or a sensor, is faulty. In order to analyze controller induced performance both an error and a change in error of the system output are chosen as fuzzy variables. The fuzzy logic for a sensor induced performance uses two variables : a deviation between two sensor outputs and its frequency. Fuzzy weighting modulator generates an output signal compensated for faulty input signal. Simulations show that the proposed fault tolerant control scheme for a steam generator regulates well water level by suppressing fault effect of either controllers or sensors. Therefore through duplicating sensors and controllers with the proposed fault tolerant scheme, both a reliability of a steam generator control and sensor system and that of a power plant increase even more. 2 refs., 9 figs., 1 tab. (Author)

  19. Brush Seals for Improved Steam Turbine Performance

    Science.gov (United States)

    Turnquist, Norman; Chupp, Ray; Baily, Fred; Burnett, Mark; Rivas, Flor; Bowsher, Aaron; Crudgington, Peter

    2006-01-01

    GE Energy has retrofitted brush seals into more than 19 operating steam turbines. Brush seals offer superior leakage control compared to labyrinth seals, owing to their compliant nature and ability to maintain very tight clearances to the rotating shaft. Seal designs have been established for steam turbines ranging in size from 12 MW to over 1200 MW, including fossil, nuclear, combined-cycle and industrial applications. Steam turbines present unique design challenges that must be addressed to ensure that the potential performance benefits of brush seals are realized. Brush seals can have important effects on the overall turbine system that must be taken into account to assure reliable operation. Subscale rig tests are instrumental to understanding seal behavior under simulated steam-turbine operating conditions, prior to installing brush seals in the field. This presentation discusses the technical challenges of designing brush seals for steam turbines; subscale testing; performance benefits of brush seals; overall system effects; and field applications.

  20. Research on Mechanisms of Steam Breakthrough and Profile Control Design for Steam Soaking Well

    Institute of Scientific and Technical Information of China (English)

    Liu Huiqing; Zhang Hongling; Wang Shulin; Wang Han; Bao Shucheng

    2006-01-01

    Scaled physical model tests for steam breakthrough were conducted based on the analysis of mechanisms and influence factors of steam breakthrough. Physical simulation results showed that at the initial steam breakthrough, preferential flow channels were formed in narrow sand packs and most residual oil left in these channels was immobile. This shortened the steam breakthrough time of follow-up steam flooding and decreased the increment of oil recovery efficiency. Steam breakthrough occurred easily for a smaller producer-injector spacing, and a bigger difference in physical properties between fluids and rock. Steam breakthrough is more likely to occur at a larger formation permeability (k), greater steam displacement velocity (u) and smaller producer-injector spacing (L). Steam breakthrough time is a function of the parameter group (uk/L), i.e. tb=3.2151 (uk/L) -0.5142. A non piston-like displacement model was built based on steam breakthrough observation for a steam stimulated well in the Jinglou Oilfield, Henan Oilfield Company. The steam volume swept in different directions could be obtained from inter-well permeability capacity and breakthrough angle, and the steam swept pore volume (SSPV) was also determined. Numerical simulation showed that steam sweep efficiency reached its peak value when a slug of profile control agent (slug size 10%-15% SSPV) was set at one half of the inter-well spacing. Field test with 12.5% SSPV of profile control agents in the Jinglou Oilfield achieved success in sealing breakthrough channels and good production performance of adjacent producers.

  1. Microbial activity in soils following steam treatment.

    Science.gov (United States)

    Richardson, Ruth E; James, C Andrew; Bhupathiraju, Vishvesh K; Alvarez-Cohen, Lisa

    2002-01-01

    Steam enhanced extraction (SEE) is an aquifer remediation technique that can be effective at removing the bulk of non-aqueous phase liquid (NAPL) contamination from the subsurface, particularly highly volatile contaminants. However, low volatility compounds such as polynuclear aromatic hydrocarbons (PAHs) are less efficiently removed by this process. This research evaluated the effects of steam injection on soil microbial activity, community structure, and the potential for biodegradation of contaminants following steam treatment. Three different soils were evaluated: a laboratory-prepared microbially-enriched soil, soil from a creosote contaminated field site, and soil from a chlorinated solvent and waste oil contaminated field site. Results from field-scale steaming are also presented. Microbial activity before and after steam treatment was evaluated using direct epifluorescent microscopy (DEM) using the respiratory activity dye 5-cyano-2,3, ditolyl tetrazolium chloride (CTC) in conjunction with the fluorochrome 5-(4,6-dichlorotriazinyl) aminofluorescein (DTAF) to yield a quantitative assessment of active and total microbial numbers. DEM results indicate that steamed soils that were analyzed while still hot exhibited microbial activity levels that were below detection. However, soil samples that were slowly cooled, more closely reflecting the conditions of applied SEE, exhibited microbial activity levels that were comparable to presteamed soils. Samples from a field-site where steam was applied continuously for 6 weeks also showed high levels of microbial activity following cooling. The metabolic capabilities of the steamed communities were investigated by measuring cell growth in enrichment cultures on various substrates. These studies provided evidence that organisms capable of biodegradation were among the mesophilic populations that survived steam treatment. Fluorescent in situ hybridization (FISH) analysis of the soils with domain-level rRNA probes suggest

  2. Modelling of WWER-1000 steam generators by REALP5/MOD3.2 code

    Energy Technology Data Exchange (ETDEWEB)

    D`Auria, F.; Galassi, G.M. [Univ. of Pisa (Italy); Frogheri, M. [Univ. of Genova (Italy)

    1997-12-31

    The presentation summarises the results of best estimate calculations carried out with reference to the WWER-1000 Nuclear Power Plant, utilizing a qualified nodalization set-up for the Relap5/Mod3.2 code. The nodalization development has been based on the data of the Kozloduy Bulgarian Plant. The geometry of the steam generator imposed drastic changes in noding philosophy with respect to what is suitable for the U-tubes steam generators. For the secondary side a symmetry axis was chosen to separate (in the nodalization) the hot and the cold sides of the tubes. In this way the secondary side of the steam generators was divided into three zones: (a) the hot zone including the hot collector and the hot l/2 parts of the tubes; (b) the cold zone including the cold collector and the cold 1/2 parts of the tubes; (c) the downcomer region, where down flow is assumed. As a consequence of above in the primary side more nodes are placed on the hot side of the tubes. Steady state and transient qualification has been achieved, considering the criteria proposed at the University of Pisa, utilizing plant transient data from the Kozloduy and the Ukrainian Zaporosche Plants. The results of the application of the qualified WWER-1000 Relap5/Mod3.2 nodalization to various transients including large break LOCA, small break LOCA and steam generator tube rupture, together with a sensitivity analysis on the steam generators, are reported in the presentation. Emphasis is given to the prediction of the steam generators performances. 23 refs.

  3. Investigations on catalyzed steam gasification of biomass

    Energy Technology Data Exchange (ETDEWEB)

    Mudge, L.K.; Weber, S.L.; Mitchell, D.H.; Sealock, L.J. Jr.; Robertus, R.J.

    1981-01-01

    The purpose of the study is to evaluate the technical and economic feasibility of producing specific gas products via the catalytic gasification of biomass. This report presents the results of research conducted from December 1977 to October 1980. The study was comprised of laboratory studies, process development, and economic analyses. The laboratory studies were conducted to develop operating conditions and catalyst systems for generating methane-rich gas, synthesis gases, hydrogen, and carbon monoxide; these studies also developed techniques for catalyst recovery, regeneration, and recycling. A process development unit (PDU) was designed and constructed to evaluate laboratory systems at conditions approximating commercial operations. The economic analyses, performed by Davy McKee, Inc. for PNL, evaluated the feasibility of adapting the wood-to-methane and wood-to-methanol processes to full-scale commercial operations. Plants were designed in the economic analyses to produce fuel-grade methanol from wood and substitute natural gas (SNG) from wood via catalytic gasification with steam.

  4. Comparison between field and laboratory steam oxidation testing on aluminide coatings on P92

    Energy Technology Data Exchange (ETDEWEB)

    Agueero, A.; Gonzalez, V.; Gutierrez, M. [Instituto Nacional de Tecnica Aeroespacial, Ctra. Ajalvir Km 4, 28850 Torrejon de Ardoz (Spain); Knoedler, R.; Straub, S. [Alstom Power Systems GmbH, Boveristrasse 22, 68309 Mannheim (Germany); Muelas, R. [Ingenieria y Servicios Aeroespaciales, P Pintor Rosales 34, 28008 Madrid (Spain)

    2011-06-15

    Steam oxidation has become an important issue for steam power plants as operating temperatures increase from the current 550 to 600-650 C. For the last 10 years several groups have been carrying out steam oxidation testing of both uncoated substrates and coatings in the laboratory. On the other hand, field testing results are very scarce. In this paper, a comparison of laboratory steam oxidation testing with field test results carried out by Alstom at the Kraftwerk Westfalen power station located in Hamm, Germany will be presented. Both slurry deposited aluminide coatings and uncoated P92 steel have been included in the study. Under steam (atmospheric pressure) and isothermal conditions in the laboratory at 650 C, spallation of oxides formed on ferritic steels occurs after significantly longer time when compared to exposure to real operating conditions. Oxide spallation results in serious damage in steam power plants by obstructing heat exchanger tubes, erosion of valves and turbine blades, etc. Moreover, the thickness of the oxide scales formed under field testing conditions is significantly higher after similar exposure. On the other hand, aluminide coated P92, which exhibit thickness through cracks, have shown to be stable in the laboratory for up to 60 000 h at 650 C under steam, without evidence of crack propagation. However, field test results indicate that some degree of crack propagation occurs but without causing substrate attack up to 21 700 h of exposure. Moreover, the aluminium oxide observed in both laboratory and field tested specimens is different. (Copyright copyright 2011 WILEY-VCH Verlag GmbH and Co. KGaA, Weinheim)

  5. Cooling performance of grid-sheets for highly loaded ultra-supercritical steam turbines

    Institute of Scientific and Technical Information of China (English)

    Dieter BOHN; Robert KREWINKEL; Shuqing TIAN

    2009-01-01

    In order to increase efficiency and achieve a further CO2-reduction, the next generation of power plant turbines will have steam turbine inlet temperatures that are considerably higher than the current ones. The high pressure steam turbine inlet temperature is expected to be increased up to approximately 700℃ with a live steam pressure of 30 MPa. The elevated steam parameters in the high and intermediate pressure turbines can be encountered with Ni-base alloys, but this is a costly alternative associated with many manufacturing difficulties. Colla-borative research centre 561 "Thermally Highly Loaded,Porous and Cooled Multi-Layer Systems for Combined Cycle Power Plants" at RWTH Aachen University proposes cooling the highly loaded turbines instead, as this would necessitate the application of far less Ni-base alloys.To protect the thermally highly loaded components, a sandwich material consisting of two thin face sheets and a core made from a woven wire mesh is used to cover the walls of the steam turbine casing. The cooling steam is led through the woven wire mesh between the two face sheets to achieve a cooling effect. The wire mesh provides the grid-sheet with structural rigidity under varying operating conditions.In the present work, the cooling performance of the grid-sheets will be investigated applying the conjugate heat transfer method to ultra-supercritical live and cooling steam conditions for a section of the cooling structure. The behaviour of the flow and the heat transfer in the grid-sheet will be analyzed in detail using a parameter variation. The numerical results should give a first prediction of the cooling performance under future operating conditions.

  6. Enhanced tubes for steam condensers. Volume 1, Summary of condensation and fouling; Volume 2, Detailed study of steam condensation

    Energy Technology Data Exchange (ETDEWEB)

    Webb, R.L.; Chamra, L.; Jaber, H.

    1992-02-01

    Electric utility steam condensers typically use plain tubes made of titanium, stainless steel, or copper alloys. Approximately two-thirds of the total thermal resistance is on the water side of the plain tube. This program seeks to conceive and develop a tube geometry that has special enhancement geometries on the tube (water) side and the steam (shell) side. This ``enhanced`` tube geometry, will provide increased heat transfer coefficients. The enhanced tubes will allow the steam to condense at a lower temperature. The reduced condensing temperature will reduce the turbine heat rate, and increase the plant peak load capability. Water side fouling and fouling control is a very important consideration affecting the choice of the tube side enhancement. Hence, we have consciously considered fouling potential in our selection of the tube side surface geometry. Using appropriate correlations and theoretical models, we have designed condensation and water side surface geometries that will provide high performance and be cleanable using sponge ball cleaning. Commercial tube manufacturers have made the required tube geometries for test purposes. The heat transfer test program includes measurement of the condensation and water side heat transfer coefficients. Fouling tests are being run to measure the waterside fouling resistance, and to the test the ability of the sponge ball cleaning system to clean the tubes.

  7. Ecotaxes and their impact in the cost of steam and electric energy generated by a steam turbine system

    Energy Technology Data Exchange (ETDEWEB)

    Montero, Gisela [Universidad Autonoma de Baja California, Mexicali, B.C. (Mexico). Instituto de Ingenieria; Pulido, Ricardo; Pineda, Carlos; Rivero, Ricardo [Instituto Mexicano del Petroleo, Eje Lazaro Cardenas, D.F. (Mexico)

    2006-12-15

    Ecotaxes allow the internalization of costs that are considered externalities associated with polluting industrial process emissions to the atmosphere. In this paper, ecotaxes internalize polluting emissions negative impacts that are added to electricity and steam generated costs of a steam turbine and heat recovery systems from a utilities refinery plant. Steam costs were calculated by means of an exergy analysis tool and Aspen Plus simulation models. Ecotaxes were calculated for specific substances emitted in the refinery flue gases, based on a toxicity and pollution scale. Ecotaxes were generated from a model that includes damages produced to biotic and abiotic resources and considers the relative position of those substances in a toxicity and pollution scale. These ecotaxes were internalized by an exergoeconomic analysis resulting in an increase in the cost per kWh produced. This kind of ecotax is not applied in Mexico. The values of ecotaxes used in the cost determination are referred to the values currently applied by some European countries to nitrogen oxides emissions. (author)

  8. Optimization of cold end system of steam turbine

    Institute of Scientific and Technical Information of China (English)

    Bin ZHAO; Ling LIU; Wenbing ZHANG

    2008-01-01

    An optimization of the movement character-istic of the cold end system of the steam turbine was con-ducted from an overall consideration of the condenser and the circulation water pump. An analysis method based on thermodynamics theory that fixes coupling characteristic between the best vacuum and the best circulation dis-charge of water was proposed. The proposed method was applied to the optimized analysis of the operating mode of the cold end system of a 300 MW unit in a power plant.

  9. Cost-optimized design approach for steam condensers

    Energy Technology Data Exchange (ETDEWEB)

    Kurma Rao, P.S.V.

    1982-08-23

    Examines methods of selecting cooling water quality for a steam surface condenser operating in a power plant or in a process. Equations and graphs for determining optimum terminal temperature difference and optimum cooling water velocity are presented. With large quantity with large terminal temperature difference, water cost will be more, but the annual fixed charges for maintenance will be smaller because the surface area is less due to the large terminal temperature difference. With high velocities giving high heat transfer rates with less surface area, initial costs are low, but pumping costs will be higher.

  10. Development of a Nuclear Hydrogen Production System by Dimethyl Ether (DME) Steam Reforming and Related Technology

    Science.gov (United States)

    Fukushima, Kimichika; Oota, Hiroyuki; Yamada, Kazuya; Makino, Shinichi; Yagyu, Motoshige; Ikeda, Tatsumi; Asayama, Masahiro; Ogawa, Takashi; Yoshino, Masato

    Targeting a hydrogen production system using heat produced by a nuclear reactor at about 300°C, we are developing a dimethyl ether (DME) steam reformer and hydrogen purification systems as well as catalysts for DME reforming. The use of heat from a nuclear reactor suppresses the CO2 concentration change in the atmosphere. In our developments, a catalyst, consisting of mixed oxides, produced hydrogen at a rate of about 1.9 Nm3/h per catalyst volume (m3) at about 300°C. Subsequently, the DME steam reformer achieved a hydrogen production rate of approximately, at least, 1.4 Nm3/h at about 300°C, by absorbing heat from the supplied steam. The aforementioned hydrogen production system via DME steam reforming is to be demonstrated using a thermal power plant. DME steam reforming by using waste heat and the utilization of the produced hydrogen within a combined cycle power plant can reduce fuel consumption, for instance, by about 17% compared to the case of direct DME combustion. The total system, with the use of DME, was compared with the methane case. If necessary, the byproduced CO2 may be injected into coal seams, increasing CH4 production via the substitution of CO2 for CH4 on coal, where CO2 adsorption is expected to be stronger than the CH4 adsorption.

  11. Solid particle erosion of steels and nickel based alloys candidates for USC steam turbine blading

    Energy Technology Data Exchange (ETDEWEB)

    Cernuschi, Federico; Guardamagna, Cristina; Lorenzoni, Lorenzo [ERSE SpA, Milan (Italy); Robba, Davide [CESI, Milan (Italy)

    2010-07-01

    The main objective of COST536 Action is to develop highly efficient steam power plant with low emissions, from innovative alloy development to validation of component integrity. In this perspective, to improve the operating efficiency, materials capable of withstanding higher operating temperatures are required. For the manufacturing of components for steam power plants with higher efficiency steels and nickel-based alloys with improved oxidation resistance and creep strength at temperature as high as 650 C - 700 C have to be developed. Candidate alloys for manufacturing high pressure steam turbine diaphragms, buckets, radial seals and control valves should exhibit, among other properties, a good resistance at the erosion phenomena induced by hard solid particles. Ferric oxide (magnetite) scales cause SPE by exfoliating from boiler tubes and steam pipes (mainly super-heaters and re-heaters) and being transported within the steam flow to the turbine. In order to comparatively study the erosion behaviour of different materials in relatively short times, an accelerated experimental simulation of the erosion phenomena must be carried out. Among different techniques to induce erosion on material targets, the use of an air jet tester is well recognised to be one of the most valid and reliable. In this work the results of SPE comparative tests performed at high temperatures (550 C, 600 C and 650 C) at different impaction angles on some steels and nickel based alloys samples are reported. (orig.)

  12. Analysis of experimental characteristics of multistage steam-jet electors of steam turbines

    Science.gov (United States)

    Aronson, K. E.; Ryabchikov, A. Yu.; Brodov, Yu. M.; Brezgin, D. V.; Zhelonkin, N. V.; Murmanskii, I. B.

    2017-02-01

    A series of questions for specification of physical gas dynamics model in flow range of steam-jet unit and ejector computation methodology, as well as functioning peculiarities of intercoolers, was formulated based on analysis of experimental characteristics of multistage team-jet steam turbines. It was established that coefficient defining position of critical cross-section of injected flow depends on characteristics of the "sound tube" zone. Speed of injected flow within this tube may exceed that of sound, and pressure jumps in work-steam decrease at the same time. Characteristics of the "sound tube" define optimal axial sizes of the ejector. According to measurement results, the part of steam condensing in the first-stage coolant constitutes 70-80% of steam amount supplied into coolant and is almost independent of air content in steam. Coolant efficiency depends on steam pressure defined by operation of steam-jet unit of ejector of the next stage after coolant of steam-jet stage, temperature, and condensing water flow. As a rule, steam entering content of steam-air mixture supplied to coolant is overheated with respect to saturation temperature of steam in the mixture. This should be taken into account during coolant computation. Long-term operation causes changes in roughness of walls of the ejector's mixing chamber. The influence of change of wall roughness on ejector characteristic is similar to the influence of reverse pressure of the steam-jet stage. Until some roughness value, injection coefficient of the ejector stage operating in superlimiting regime hardly changed. After reaching critical roughness, the ejector switches to prelimiting operating regime.

  13. Characteristics Evaluation of a CO2-Caputuring Power Generation System with Reheat Cycle Utilizing Regenerative Oxygen-Combustion Steam-Superheater

    Science.gov (United States)

    Pak, Pyong Sik

    A new CO2-capturing power generation system is proposed that can be easily realized by applying conventional technologies. In the proposed system, the temperature of middle-pressure steam in a thermal power plant is raised by utilizing oxygen-combusting regenerative steam-superheater. The generated CO2 by combusting fuel in the superheater can be easily separated and captured from the exhaust gas at condenser outlet, and is liquefied. The superheated steam is used to drive a steam turbine power generation system. By adopting a high efficient combined cycle power generation system as an example, it has been shown that the proposed system can increase power output by 10.8%, decrease the CO2 emission amount of the total integrated system by 18.6% with power generation efficiency drop of 2.36% compared with the original power plant without CO2-capture, when superheated steam temperature is 750°C

  14. Effects of steam distillation on extraction, composition, and functional properties of coriander (Coriandrum sativum L.) proteins

    Science.gov (United States)

    Coriander (Coriandrum sativum L.) is a summer annual plant commonly used as fresh green herb, spice, or for its essential oil. A newly-developed process combined steam distillation and mechanical pressing to recover the essential oil and edible oil, respectively, from dehulled coriander seeds. The c...

  15. New type steam turbine for cogeneration

    Institute of Scientific and Technical Information of China (English)

    He Jianren; Yang Qiguo; Xu Damao

    2010-01-01

    A concept of energy saving & efficiency improving from cold source for cogeneration steam turbine was discussed herein.A new type"NCB"cogeneration steam turbine was proposed,which could considerably increase heat supply capacity,thermal efficiency and electric power.Taking 300 MW cogeneration steam turbine as an example,the results show that heat supply capacity reaches the maximum,i.e.increases by 30%,thermal efficiency is improved by12%,and electric power is enhanced by 15 MW during peak heat load.

  16. Selective hydrogenation processes in steam cracking

    Energy Technology Data Exchange (ETDEWEB)

    Bender, M.; Schroeter, M.K.; Hinrichs, M.; Makarczyk, P. [BASF SE, Ludwigshafen (Germany)

    2010-12-30

    Hydrogen is the key elixir used to trim the quality of olefinic and aromatic product slates from steam crackers. Being co-produced in excess amounts in the thermal cracking process a small part of the hydrogen is consumed in the ''cold part'' of a steam cracker to selectively hydrogenate unwanted, unsaturated hydrocarbons. The compositions of the various steam cracker product streams are adjusted by these processes to the outlet specifications. This presentation gives an overview over state-of-art selective hydrogenation technologies available from BASF for these processes. (Published in summary form only) (orig.)

  17. Analysis and decision document in support of acquisition of steam supply for the Hanford 200 Area

    Energy Technology Data Exchange (ETDEWEB)

    Brown, D.R.; Daellenbach, K.K.; Hendrickson, P.L.; Kavanaugh, D.C.; Reilly, R.W.; Shankle, D.L.; Smith, S.A.; Weakley, S.A.; Williams, T.A. [Pacific Northwest Lab., Richland, WA (United States); Grant, T.F. [Battelle Human Affairs Research Center, Seattle, WA (United States)

    1992-02-01

    The US Department of Energy (DOE) is now evaluating its facility requirements in support of its cleanup mission at Hanford. One of the early findings is that the 200-Area steam plants, constructed in 1943, will not meet future space heating and process needs. Because the 200 Area will serve as the primary area for waste treatment and long-term storage, a reliable steam supply is a critical element of Hanford operations. This Analysis and Decision Document (ADD) is a preliminary review of the steam supply options available to the DOE. The ADD contains a comprehensive evaluation of the two major acquisition options: line-term versus privatization. It addresses the life-cycle costs associated with each alternative, as well as factors such as contracting requirements and the impact of market, safety, security, and regulatory issues. Specifically, this ADD documents current and future steam requirements for the 200 Area, describes alternatives available to DOE for meeting these requirements, and compares the alternatives across a number of decision criteria, including life-cycle cost. DOE has currently limited the ADD evaluation alternatives to replacing central steam plants rather than expanding the study to include alternative heat sources, such as a distributed network of boilers or heat pumps. Thirteen project alternatives were analyzed in the ADD. One of the alternatives was the rehabilitation of the existing 200-East coal-fired facility. The other twelve alternatives are combinations of (1) coal- or gas-fueled plants, (2) steam-only or cogeneration facilities, (3) primary or secondary cogeneration of electricity, and (4) public or private ownership.

  18. 49 CFR 230.21 - Steam locomotive number change.

    Science.gov (United States)

    2010-10-01

    ... 49 Transportation 4 2010-10-01 2010-10-01 false Steam locomotive number change. 230.21 Section 230... Recordkeeping Requirements § 230.21 Steam locomotive number change. When a steam locomotive number is changed, the steam locomotive owner and/or operator must reflect the change in the upper right-hand corner...

  19. Caracterización del envejecimiento de tuberías de vapor de centrales térmicas empleando el efecto Barkhausen//Characterization of steam pipes ageing degree from power plants using magnetic Barkhausen noise

    Directory of Open Access Journals (Sweden)

    Frank de los Reyes-Rodríguez

    2012-05-01

    Full Text Available En este trabajo se caracteriza el grado de envejecimiento del acero 12Cr1MoV con el ruido magnético de Barkhausen por dos métodos. Para ello se realiza un estudio de la evolución microestructural en condiciones de operación (15MPa, 550ºC desde 100000 h a 150000 h, utilizando técnicas de microscopía óptica y electrónica de barrido. En el primer método los experimentos revelan una disminución de la raíz cuadrada media del voltaje con el tiempo de explotación, lo cual se atribuye a la disminución del número de paredes de dominio por unidad de área con el aumento del tamaño de grano. En el segundo método se evalúa el nivel de esferoidización y el tamaño medio de los carburos a partir de la altura total del segundo pico de la envolvente de la señal Barkhausen, mostrando una disminución debido a un cambio en la forma acicular y en el tamaño medio de los carburos. Palabras claves: grado de envejecimiento, ruido barkhausen, tuberías de vapor, carburos._______________________________________________________________________________ Abstract In this paper, an ageing degree characterization of 12Cr1MoV steel using two method of magnetic Barkhausen noise is developed. A study of the microstructural evolution during ageing at operated conditions (15MPa, 550ºC from 100000 h up to 150000 h was carried out using optic and scanning electron microscopy techniques. In the first method the experiments reveal a decreasing of root mean square of voltage with the ageing time, which is attributed to the decreasing of domain walls number per area units with the grain size increasing. In the second method the spheroidization level/average size of carbides was analyzed too with the total second peak height, determining a decreasing due to the change of the shape, size and acicularity of carbides phase. Key words: ageing degree, barkhausen noise, steam pipes, carbides.

  20. An Improved Steam Injection Model with the Consideration of Steam Override

    Directory of Open Access Journals (Sweden)

    He Congge

    2017-01-01

    Full Text Available The great difference in density between steam and liquid during wet steam injection always results in steam override, that is, steam gathers on the top of the pay zone. In this article, the equation for steam override coefficient was firstly established based on van Lookeren’s steam override theory and then radius of steam zone and hot fluid zone were derived according to a more realistic temperature distribution and an energy balance in the pay zone. On this basis, the equation for the reservoir heat efficiency with the consideration of steam override was developed. Next, predicted results of the new model were compared with these of another analytical model and CMG STARS (a mature commercial reservoir numerical simulator to verify the accuracy of the new mathematical model. Finally, based on the validated model, we analyzed the effects of injection rate, steam quality and reservoir thickness on the reservoir heat efficiency. The results show that the new model can be simplified to the classic model (Marx-Langenheim model under the condition of the steam override being not taken into account, which means the Marx-Langenheim model is corresponding to a special case of this new model. The new model is much closer to the actual situation compared to the Marx-Langenheim model because of considering steam override. Moreover, with the help of the new model, it is found that the reservoir heat efficiency is not much affected by injection rate and steam quality but significantly influenced by reservoir thickness, and to ensure that the reservoir can be heated effectively, the reservoir thickness should not be too small.

  1. Study of Scaling Development on Tube Surfaces of Water Steam Loop in Steam Generator of CEFR

    Institute of Scientific and Technical Information of China (English)

    ZHANG; Lu; LIU; Fu-chen; LUO; De-kang; WU; Qiang; ZHANG; Huan-qi

    2012-01-01

    <正>The steam generator worked as pressure boundary of Na-H2O loop in China Experimental FastReactor (CEFR), which was quite important for nuclear reactor safety. Once the tubes separating the water from steam leak because of corrosion by scaling, Na-H2O reaction would lead to severe accident. So it’s critically important to study how the scaling develops on the water-steam sides.

  2. PREDICTION OF OXIDE SCALE EXFOLIATION IN STEAM TUBES

    Energy Technology Data Exchange (ETDEWEB)

    Sabau, Adrian S [ORNL; Wright, Ian G [ORNL

    2010-01-01

    Numerical simulation results are presented for the prediction of the likelihood of oxide scale exfoliation from superheater tubes. The scenarios considered involved alloys T22, TP347H, and TP347HFG subjected to a simplified operating cycle in a power plant generating supercritical steam. The states of stress and strain of the oxides grown in steam were based solely on modeling the various phenomena experienced by superheater tubes during boiler operation, current understanding of the oxidation behavior of each alloy in steam, and consideration of operating parameters such as heat flux, tube dimensions, and boiler duty cycle. Interpretation of the evolution of strain in these scales, and the approach to conditions where scale failure (hence exfoliation) is expected, makes use of the type of Exfoliation Diagrams that incorporate various cracking and exfoliation criteria appropriate for the system considered. In these diagrams, the strain accumulation with time in an oxide is represented by a strain trajectory derived from the net strain resulting from oxide growth, differences in coefficients of thermal expansion among the components, and relaxation due to creep. It was found that an oxide growing on a tube subjected to routine boiler load cycling conditions attained relatively low values of net strain, indicating that oxide failure would not be expected to occur during normal boiler operation. However, during a boiler shut-down event, strains sufficient to exceed the scale failure criteria were developed after times reasonably in accord with plant experience, with the scales on the ferritic steel failing in tension, and those on the austenitic steels in compression. The results presented illustrate that using this approach to track the state of strain in the oxide scale through all phases of boiler operation, including transitions from full-to-low load and shut-down events, offers the possibility of identifying the phase(s) of boiler operation during which oxide

  3. Steam-Reheat Option for Supercritical-Water-Cooled Reactors

    Science.gov (United States)

    Saltanov, Eugene

    SuperCritical-Water-cooled Reactors (SCWRs) are being developed as one of the Generation-IV nuclear-reactor concepts. Main objectives of the development are to increase thermal efficiency of a Nuclear Power Plant (NPP) and to decrease capital and operational costs. The first objective can be achieved by introducing nuclear steam reheat inside a reactor and utilizing regenerative feedwater heaters. The second objective can be achieved by designing a steam cycle that closely matches that of the mature supercritical fossil-fuelled power plants. The feasibility of these objectives is discussed. As a part of this discussion, heat-transfer calculations have been performed and analyzed for SuperCritical-Water (SCW) and SuperHeated-Steam (SHS) channels of the proposed reactor concept. In the calculations a uniform and three non-uniform Axial Heat Flux Profiles (AHFPs) were considered for six different fuels (UO2, ThO 2, MOX, UC2, UC, and UN) and at average and maximum channel power. Bulk-fluid, sheath, and fuel centerline temperatures as well as the Heat Transfer Coefficient (HTC) profiles were obtained along the fuel-channel length. The HTC values are within a range of 4.7--20 kW/m2·K and 9.7--10 kW/m2·K for the SCW and SHS channels respectively. The main conclusion is that while all the mentioned fuels may be used for the SHS channel, only UC2, UC, or UN are suitable for a SCW channel, because their fuel centerline temperatures are at least 1000°C below melting point, while that of UO2, ThO2 , and MOX may reach melting point.

  4. Feasibility of leak-detection instrumentation for duplex-tube steam generator. [LMFBR

    Energy Technology Data Exchange (ETDEWEB)

    Berkey, E.; Witkowski, R.E.

    1974-01-01

    A literature search has been carried out to determine if current state-of-the-art for sodium vapor and water vapor detectors are feasible as leak detection instrumentation for the Westinghouse duplex-tube steam generator. A commercially available probe-type water vapor detector has been identified and a thermal ionization type sodium vapor detector, currently being developed by Westinghouse, has been selected as the reference sodium-vapor leak detector. Recommendations are made concerning the experimental studies required to adapt the selected instrumentation to steam-generator plant applications. Proposed future instrumentation development programs are also identified.

  5. Bituminous coal fired USC power plants for the European market

    Energy Technology Data Exchange (ETDEWEB)

    Klebes, J.; Tigges, K.-D.; Klauke, F.; Busekrus, K. [Hitachi Power Europe GmbH (Germany)

    2007-07-01

    The presentation, in slide/viewgraph form, is in sections entitled: Introduction; Steam generator design features; Optimization of plant efficiency; Steam turbine design features (USC material design principles; rotating and stationary blades; last stage blade (LP 48 inch)); and Future developments. The presentation includes a chart of recent highly efficient coal-fired power plants in Japan, China and Germany.

  6. Steam generator asset management: integrating technology and asset management

    Energy Technology Data Exchange (ETDEWEB)

    Shoemaker, P.; Cislo, D. [AREVA NP Inc., Lynchburg, Virginia (United States)]. E-mail: paul.shoemaker@areva.com

    2006-07-01

    , reactor vessels, and nuclear fuel, are the most costly components within a nuclear steam supply system, yet they don't lend themselves well to asset management practices. However, application of asset management principles to these components represents the largest potential return for asset management within nuclear generation and sustaining continued plant operation, to include life extensions. Recognizing this critical gap, AREVA launched a Steam Generator Secondary Side Vision to develop advanced technologies for the management of nuclear steam generators. These technologies include advanced mitigation techniques, to include non-invasive techniques, new inspection techniques, predictive modeling and expert systems aimed at minimizing and managing steam generator corrosion and risks. (author)

  7. In-vessel coolability and steam explosion in Nordic BWRs

    Energy Technology Data Exchange (ETDEWEB)

    Ma, W.; Hansson, R.; Li, L.; Kudinov, P.; Cadinu, F.; Tran, C-.T. (Royal Institute of Technology (KTH), Stockholm (Sweden))

    2010-05-15

    The INCOSE project is to reduce the uncertainty in quantification of steam explosion risk and in-vessel coolability in Nordic BWR plants with the cavity flooding as a severe accident management (SAM) measure. During 2009 substantial advances and new insights into physical mechanisms were gained for studies of: (i) in-vessel corium coolability - development of the methodologies to assess the efficiency of the control rod guide tube (CRGT) cooling as a potential SAM measure; (ii) debris bed coolability - characterization of the effective particle diameter of multi-size particles and qualification of friction law for two-phase flow in the beds packed with multi-size particles; and (iii) steam explosion - investigation of the effect of binary oxides mixture's properties on steam explosion. An approach for coupling of ECM/PECM models with RELAP5 was developed to enhance predictive fidelity for melt pool heat transfer. MELCOR was employed to examine the CRGT cooling efficiency by considering an entire accident scenario, and the simulation results show that the nominal flowrate (approx10kg/s) of CRGT cooling is sufficient to maintain the integrity of the vessel in a BWR of 3900 MWth, if the water injection is activated no later than 1 hour after scram. The POMECO-FL experimental data suggest that for a particulate bed packed with multi-size particles, the effective particle diameter can be represented by the area mean diameter of the particles, while at high velocity (Re>7) the effective particle diameter is closer to the length mean diameter. The pressure drop of two-phase flow through the particulate bed can be predicted by Reed's model. The steam explosion experiments performed at high melt superheat (>200oC) using oxidic mixture of WO3-CaO didn't detect an apparent difference in steam explosion energetics and preconditioning between the eutectic and noneutectic melts. This points out that the next step of MISTEE experiment will be conducted at lower

  8. US PWR steam generator management: An overview

    Energy Technology Data Exchange (ETDEWEB)

    Welty, C.S. Jr. [Electric Power Research Institute, Palo Alto, CA (United States)

    1997-02-01

    This paper provides an overview on the status of steam generator management activities in US PWRs, and includes: (1) an overview of the impact of steam generator problems; (2) a brief discussion of historical damage trends and the current damage mechanism of most concern; (3) a discussion of the elements of {open_quotes}steam generator management{close_quotes}; and (4) a description of the approach being followed to implement a degradation-specific protocol for tubing inspection and repair. This paper was prepared in conjunction with another paper presented during the Plenary Session of this Conference, {open_quotes}Steam Generator Degradation: Current Mitigation Strategies for Controlling Corrosion{close_quotes}, and is provided as a supplement to that material.

  9. Biophysical Evaluation of SonoSteam®:

    DEFF Research Database (Denmark)

    Andersen, Ann Zahle; Duelund, Lars; Brewer, Jonathan R.;

    and safety evaluations. Our results show that there are no contradictions between data obtained by either approach. However, the biophysical methods draw a much more nuanced picture of the effects and efficiency of the investigated decontamination method, revealing e.g. an exponential dose/response...... relationship between SonoSteam treatment time and changes in collagen I, and a depth dependency in bacterial reduction, which points toward CFU counts overestimating total bacterial reduction. In conclusion the biophysical methods provide a less biased, reproducible and highly detailed system description......In this study we employ a biophysical and molecular approach for the investigation of qualitative and quantitative changes in both food surface and bacteria upon surface decontamination by SonoSteam®. SonoSteam® is a recently developed method of food surface decontamination, which employs steam...

  10. Thermodynamics of supersaturated steam: Molecular simulation results

    Science.gov (United States)

    Moučka, Filip; Nezbeda, Ivo

    2016-12-01

    Supersaturated steam modeled by the Gaussian charge polarizable model [P. Paricaud, M. Předota, and A. A. Chialvo, J. Chem. Phys. 122, 244511 (2005)] and BK3 model [P. Kiss and A. Baranyai, J. Chem. Phys. 138, 204507 (2013)] has been simulated at conditions occurring in steam turbines using the multiple-particle-move Monte Carlo for both the homogeneous phase and also implemented for the Gibbs ensemble Monte Carlo molecular simulation methods. Because of these thermodynamic conditions, a specific simulation algorithm has been developed to bypass common simulation problems resulting from very low densities of steam and cluster formation therein. In addition to pressure-temperature-density and orthobaric data, the distribution of clusters has also been evaluated. The obtained extensive data of high precision should serve as a basis for development of reliable molecular-based equations for properties of metastable steam.

  11. A small pelton turbine for steam turbocharger

    Energy Technology Data Exchange (ETDEWEB)

    Rautenberg, M.; Abdelkader, M.; Malobabic, M.; Mobarak, A.

    1984-08-01

    The use of exhaust gas turbocharger for internal combustion engines is usually accompanied by mechanical loss. This loss is due to the raise of exhaust gas back pressure with the increase of engine speed. This back pressure prevents the discharge of the exhaust gas from the engine and causes mechanical loss. To avoid this undesirable phenomenon, a Clausius-Rankine cycle is used. In this case the thermal energy in the exhaust gas is used to vaporise water in a steam generator. The generated steam expands in a steam turbocharger which supercharges the engine. A small Pelton steam turbine has been designed and fabricated. The expected output for this small turbine is 10 kW. A computer program has been prepared to estimate the values of optimum cycle parameters.

  12. Cogeneration steam turbines from Siemens: New solutions

    Science.gov (United States)

    Kasilov, V. F.; Kholodkov, S. V.

    2017-03-01

    The Enhanced Platform system intended for the design and manufacture of Siemens AG turbines is presented. It combines organizational and production measures allowing the production of various types of steam-turbine units with a power of up to 250 MWel from standard components. The Enhanced Platform designs feature higher efficiency, improved reliability, better flexibility, longer overhaul intervals, and lower production costs. The design features of SST-700 and SST-900 steam turbines are outlined. The SST-700 turbine is used in backpressure steam-turbine units (STU) or as a high-pressure cylinder in a two-cylinder condensing turbine with steam reheat. The design of an SST-700 single-cylinder turbine with a casing without horizontal split featuring better flexibility of the turbine unit is presented. An SST-900 turbine can be used as a combined IP and LP cylinder (IPLPC) in steam-turbine or combined-cycle power units with steam reheat. The arrangements of a turbine unit based on a combination of SST-700 and SST-900 turbines or SST-500 and SST-800 turbines are presented. Examples of this combination include, respectively, PGU-410 combinedcycle units (CCU) with a condensing turbine and PGU-420 CCUs with a cogeneration turbine. The main equipment items of a PGU-410 CCU comprise an SGT5-4000F gas-turbine unit (GTU) and STU consisting of SST-700 and SST-900RH steam turbines. The steam-turbine section of a PGU-420 cogeneration power unit has a single-shaft turbine unit with two SST-800 turbines and one SST-500 turbine giving a power output of N el. STU = 150 MW under condensing conditions.

  13. Future trends in steam coal utilisation

    Energy Technology Data Exchange (ETDEWEB)

    Broadbent, G.A.

    1999-07-01

    The history of coal production in important regions of the world and the evolution of the international steam coal trade is reviewed. Then the four main drivers for the evolution of steam coal utilisation and how they may impact different regions of the world are discussed. These drivers are: social issues, including population, wealth and employment; strategic issues like energy security and balance of payments; competitiveness; and environment.

  14. Next Generation Engineered Materials for Ultra Supercritical Steam Turbines

    Energy Technology Data Exchange (ETDEWEB)

    Douglas Arrell

    2006-05-31

    To reduce the effect of global warming on our climate, the levels of CO{sub 2} emissions should be reduced. One way to do this is to increase the efficiency of electricity production from fossil fuels. This will in turn reduce the amount of CO{sub 2} emissions for a given power output. Using US practice for efficiency calculations, then a move from a typical US plant running at 37% efficiency to a 760 C /38.5 MPa (1400 F/5580 psi) plant running at 48% efficiency would reduce CO2 emissions by 170kg/MW.hr or 25%. This report presents a literature review and roadmap for the materials development required to produce a 760 C (1400 F) / 38.5MPa (5580 psi) steam turbine without use of cooling steam to reduce the material temperature. The report reviews the materials solutions available for operation in components exposed to temperatures in the range of 600 to 760 C, i.e. above the current range of operating conditions for today's turbines. A roadmap of the timescale and approximate cost for carrying out the required development is also included. The nano-structured austenitic alloy CF8C+ was investigated during the program, and the mechanical behavior of this alloy is presented and discussed as an illustration of the potential benefits available from nano-control of the material structure.

  15. Development of the large main steam safety relief valve

    Energy Technology Data Exchange (ETDEWEB)

    Takeshima, Kikuo [Hitachi Ltd., Tokyo (Japan); Takasaki, Kiyoshi; Hamada, Nobuyoshi

    2000-02-01

    In order to control rise of reactor pressure at formation of over-pressure transition accident in a boiling water (BWR) type nuclear power plant, the numbers of the main steam safety relief valve (MSSRV) installed in a storage vessel increases with out-put in the plant, and for 1.35 MkW class improved BWR (ABWR) 18 sets of MSSRV are installed. And, in an ABWR preparing of construction at Ohma-cho, Aomori prefecture by the Electric Power Development Co., Ltd., uranium-plutonium mixed oxides (MOX) fuel is planned to load, to tend to further increase required numbers of MSSRV. In order to control arrangement in a storage vessel and increase of conservative inspection work together with increase the required numbers of MSSRV, it was planned to develop a large volume of MSSRV (16% increase in volume on comparison with that of conventional one), to confirm its function and feature by its testing and to apply to an actual machine. Here was introduced on its developmental contents and testing results. As a result, it could be estimated that required numbers of MSSRV would be sixteen, and was confirmed that features such as correlation on flowing-out pressure between nitrogen and steam, durability, work stability, valve seat leakage resistance, and so forth were similar to those of present MSSRV. (G.K.)

  16. Two-Phase Flow Field Simulation of Horizontal Steam Generators

    Directory of Open Access Journals (Sweden)

    Ataollah Rabiee

    2017-02-01

    Full Text Available The analysis of steam generators as an interface between primary and secondary circuits in light water nuclear power plants is crucial in terms of safety and design issues. VVER-1000 nuclear power plants use horizontal steam generators which demand a detailed thermal hydraulics investigation in order to predict their behavior during normal and transient operational conditions. Two phase flow field simulation on adjacent tube bundles is important in obtaining logical numerical results. However, the complexity of the tube bundles, due to geometry and arrangement, makes it complicated. Employment of porous media is suggested to simplify numerical modeling. This study presents the use of porous media to simulate the tube bundles within a general-purpose computational fluid dynamics code. Solved governing equations are generalized phase continuity, momentum, and energy equations. Boundary conditions, as one of the main challenges in this numerical analysis, are optimized. The model has been verified and tuned by simple two-dimensional geometry. It is shown that the obtained vapor volume fraction near the cold and hot collectors predict the experimental results more accurately than in previous studies.

  17. Analysis of Main Steam Safety Valve Improvement for Qinshan Nuclear Power Plant Phase 2 Unit 1 & 2%秦山第二核电厂1 & 2号机组主蒸汽安全阀改进分析

    Institute of Scientific and Technical Information of China (English)

    任春明; 陈坚刚; 黄代顺

    2015-01-01

    秦山第二核电厂1&2号机组拟将其加能助动式主蒸汽安全阀改为弹簧加载式安全阀。通过比对秦山第二核电厂3&4号机组主蒸汽安全阀设计,提出了1&2号机组主蒸汽安全阀改进方案,即第1组阀门采用弹簧加载式并调整开启整定值,并从机械设计、仪控设计和安全分析等方面论证了该方案的可行性。新的改进方案在保证安全的前提下,简化了设计,大幅减少了工程投入,同时降低了系统和控制逻辑复杂化后带来的潜在停堆风险的增加。%An improvement for Qinshan Nuclear Power Plant Phase 2 unit 1&2 ,in which the power‐operated valves are replaced with the spring‐loaded valve with setpoint adjustment for the 1st group safety valves of steam generators ,would be adpoted on the basis of comparison with similar improvement implemented in Qinshan Nuclear Power Plant Phase 2 unit 3&4 .The feasibility was evaluated from several aspects ,including mechanical design ,instrument & control design and safety analysis .On the premise of guaranteeing safety ,this improvement can simplify design ,observably reduce project costs and avoid increasing the potential probability of the reactor trip risk induced by complication of the system and control logic .

  18. Nonlinear variable structure excitation and steam valving controllers for power system stability

    Institute of Scientific and Technical Information of China (English)

    Ben WANG; Zongyuan MAO

    2009-01-01

    A set of novel nonlinear variable structure excitation and steam-valving controllers are proposed in this paper.On the basis of the classical dynamic equations of a generator,excitation control and steam valving control are si-multaneously considered.Design of these controllers combines the differential geometry theory with the variable structure controlling theory.The mathematical model in the form of "an affine nonlinear system" is set up for the control design of a large-scale power plant.The dynamic performance of the nonlinear variable structure controllers proposed for a single ma-chine connected to an infinite bus power system is simulated.Simulation results show that the nonlinear variable structure excitation and steam-valving controllers give satisfactory dynamic performance and good robustness.

  19. Dynamic Modeling of Steam Condenser and Design of PI Controller Based on Grey Wolf Optimizer

    Directory of Open Access Journals (Sweden)

    Shu-Xia Li

    2015-01-01

    Full Text Available Shell-and-tube condenser is a heat exchanger for cooling steam with high temperature and pressure, which is one of the main kinds of heat exchange equipment in thermal, nuclear, and marine power plant. Based on the lumped parameter modeling method, the dynamic mathematical model of the simplified steam condenser is established. Then, the pressure PI control system of steam condenser based on the Matlab/Simulink simulation platform is designed. In order to obtain better performance, a new metaheuristic intelligent algorithm, grey wolf optimizer (GWO, is used to realize the fine-tuning of PI controller parameters. On the other hand, the Z-N engineering tuning method, genetic algorithm, and particle swarm algorithm are adopted for tuning PI controller parameters and compared with GWO algorithm. Simulation results show that GWO algorithm has better control performance than other four algorithms.

  20. DESIGN OF COMBINED CYCLE GENERATION SYSTEM WITH HIGH TEMPERATURE FUEL CELL AND STEAM TURBINE

    Institute of Scientific and Technical Information of China (English)

    Yu Lijun; Yuan Junqi; Cao Guangyi

    2003-01-01

    For environment protection and high efficiency, development of new concept power plant has been required in China. The fuel cell is expected to be used in a power plant as a centralized power station or distributed power plant. It is a chemical power generation device that converts the energy of a chemical reaction directly into electrical energy and not limited by Carnot cycle efficiency. The molten carbonate fuel cell (MCFC) power plant has several attractive features I.e. High efficiency and lower emission of Nox and Sox. A combined cycle generation system with MCFC and steam turbine is designed. Its net electrical efficiency LHV is about 55%.